1

Air Conditioning Heating and Refrigeration Institute Comment  

Broader source: Energy.gov [DOE]

These comments are submitted by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) in response to the U.S. Department of Energy’s (DOE) notice in the July 3, 2014 Federal Register...

2

Alternative Refrigerants for Building Air Conditioning  

E-Print Network [OSTI]

The majority of building air conditioning has traditionally been achieved with vapor compression technology using CFC-I I or HCFC-22 as refrigerant fluids. CFC-11 is being successfully replaced by HCFC-123 (retrofit or new equipment) or by HFC- 134a...

Bivens, D. B.

1996-01-01T23:59:59.000Z

3

Requirements for Determining Refrigerant Charge Residential Air Conditioning Measures  

E-Print Network [OSTI]

Requirements for Determining Refrigerant Charge Residential Air Conditioning Measures Improved Refrigerant Charge Purpose Component packages require in some climate zones that split system air refrigerant charge. For the performance method, the proposed design is modeled with less efficiency

4

Date | 1Refrigeration and Air Conditioning EMA Education and Training Date | 2Refrigeration and Air Conditioning EMA Education and Training  

E-Print Network [OSTI]

Date | 1Refrigeration and Air Conditioning EMA Education and Training #12;Date | 2Refrigeration operating pressure (MOP) 5. De-humidifying (Te control) 6. Defrost funtions 7. Loss of charge detection (LOC control) 6. Defrost funtions 7. Loss of charge detection (LOC) 8. Bleed function 9. Sensor placement tips

Oak Ridge National Laboratory

5

Estimated 2017 Refrigerant Emissions of 2,3,3,3-tetrafluoropropene (HFC-1234yf) in the United States Resulting from Automobile Air Conditioning  

Science Journals Connector (OSTI)

The use of MAC systems also consumes significant quantities of fuel as compared to similar driving conditions without operating the air conditioning. ... However, turning off the air conditioner and rolling-down the windows also decreases fuel economy due to increased air drag but this scenario is not considered in these studies (1, 2). ... In 2006, the European Commission issued Directive 2006/40/EC (commonly known as the F-Gas Directive) (3), which requires new types of air-conditioned cars sold in the EU to have a refrigerant with a GWP of 150 or less starting in 2011, and all new vehicles to have a refrigerant with a GWP of 150 or less by 2017. ...

Stella Papasavva; Deborah J. Luecken; Robert L. Waterland; Kristen N. Taddonio; Stephen O. Andersen

2009-11-12T23:59:59.000Z

6

E-Print Network 3.0 - air-conditioning units part Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

fans... : Use of mechanical equipment such as refrigeration, air conditioning, heating systems, ventilating fans... -handling units and mechanical, compressed air, and electric ......

7

Magnetic Refrigeration Technology for High Efficiency Air Conditioning  

SciTech Connect (OSTI)

Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

Boeder, A; Zimm, C

2006-09-30T23:59:59.000Z

8

RHEOLOGICAL STUDY OF TWO-PHASE SECONDARY FLUIDS FOR REFRIGERATION AND AIR CONDITIONING.  

E-Print Network [OSTI]

, indirect refrigeration systems renews interest as they enable to notably reduce the use of environmental the refrigeration applications to the air-conditioning systems. However, this kind of process only remainsRHEOLOGICAL STUDY OF TWO-PHASE SECONDARY FLUIDS FOR REFRIGERATION AND AIR CONDITIONING. Mylène

Boyer, Edmond

9

New Development of Simulation Methods on Refrigeration and Air Conditioning Equipments  

Science Journals Connector (OSTI)

Development status of classical simulation technology and application status of artificial intelligence on refrigeration and air conditioning equipments were introduced. The new concept of intelligence simulat...

Cao Wensheng

2011-01-01T23:59:59.000Z

10

STATE OF CALIFORNIA ICE STORAGE AIR CONDITIONING (ISAC) UNITS  

E-Print Network [OSTI]

cooling with the compressor). Yes No #12;STATE OF CALIFORNIA ICE STORAGE AIR CONDITIONING (ISAC) UNITS CECSTATE OF CALIFORNIA ICE STORAGE AIR CONDITIONING (ISAC) UNITS CEC-CF-6R-MECH-08 (Revised 08/09) CALIFORNIA ENERGY COMMISSION INSTALLATION CERTIFICATE CF-6R-MECH-08 Ice Storage Air Conditioning (ISAC) Units

11

Global warming impacts of ozone-safe refrigerants and refrigeration, heating, and air-conditioning technologies  

SciTech Connect (OSTI)

International agreements mandate the phase-out of many chlorine containing compounds that are used as the working fluid in refrigeration, air-conditioning, and heating equipment. Many of the chemical compounds that have been proposed, and are being used in place of the class of refrigerants eliminated by the Montreal Protocol are now being questioned because of their possible contributions to global warming. Natural refrigerants are put forth as inherently superior to manufactured refrigerants because they have very low or zero global warming potentials (GWPs). Questions are being raised about whether or not these manufactured refrigerants, primarily hydrofluorocarbons (HFCs), should be regulated and perhaps phased out in much the same manner as CFCs and HCFCs. Several of the major applications of refrigerants are examined in this paper and the results of an analysis of their contributions to greenhouse warming are presented. Supermarket refrigeration is shown to be an application where alternative technologies have the potential to reduce emissions of greenhouse gases (GHG) significantly with no clear advantage to either natural or HFC refrigerants. Mixed results are presented for automobile air conditioners with opportunities to reduce GHG emissions dependent on climate and comfort criteria. GHG emissions for hermetic and factory built systems (i.e. household refrigerators/freezers, unitary equipment, chillers) are shown to be dominated by energy use with much greater potential for reduction through efficiency improvements than by selection of refrigerant. The results for refrigerators also illustrate that hydrocarbon and carbon dioxide blown foam insulation have lower overall effects on GHG emissions than HFC blown foams at the cost of increased energy use.

Fischer, S.; Sand, J.; Baxter, V.

1997-12-01T23:59:59.000Z

12

Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI  

Broader source: Energy.gov [DOE]

These comments are submitted by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) in response to the U.S. Department of Energy’s (DOE) notice in the August 8, 2012 Federal Register...

13

Impact of the Variable Refrigerant Volume Air Conditioning System on Building Energy Efficiency  

E-Print Network [OSTI]

The application of the variable refrigerant volume multi-zone air conditioning systems has met with mixed results since the publication of the Design Standard for Energy Efficiency of Public Buildings. This paper analyzes the characteristics...

Zhu, H.

2006-01-01T23:59:59.000Z

14

Energy and global warming impacts of next generation refrigeration and air conditioning technologies  

SciTech Connect (OSTI)

Significant developments have occurred in hydrofluorocarbon (HFC) and the application of ammonia and hydrocarbons as refrigerant working fluids since the original TEWI (Total Equivalent Warming Impact) report in 1991. System operating and performance data on alternative refrigerants and refrigeration technologies justify and updated evaluation of these new alternative refrigerants and competing technologies in well-characterized applications. Analytical and experimental results are used to show quantitative comparisons between HFCS, HFC blends, hydrocarbons, and ammonia, used as refrigerants. An objective evaluation is presented for commercial and near commercial non-CFC refrigerants/blowing agents and alternative refrigeration technologies. This information is needed for objective and quantitative decisions on policies addressing greenhouse gas emissions from refrigeration and air conditioning equipment. The evaluation assesses the energy use and global warming impacts of refrigeration and air conditioning technologies that could be commercialized during the phase out of HCFCS. Quantitative comparison TEWI for two application areas are presented. Opportunities for significant reductions in TEWI are seen with currently known refrigerants through improved maintenance and servicing practices and improved product designs.

Sand, J.R.; Fischer, S.K.; Baxter, V.D.

1996-10-01T23:59:59.000Z

15

Comment submitted by the Air Conditioning, Heating and Refrigeration Institute (AHRI) regarding the Energy Star Verification Testing Program  

Broader source: Energy.gov [DOE]

This document is a comment submitted by the Air Conditioning, Heating and Refrigeration Institute (AHRI) regarding the Energy Star Verification Testing Program

16

Module Development and Simulation of the Variable Refrigerant Flow Air Conditioning System under Cooling Conditions in Energyplus  

E-Print Network [OSTI]

As a high-efficiency air conditioning scheme, the variable refrigerant flow (VRF) air-conditioning system is finding its way into medium-sized office buildings. Based on a generic dynamic building energy simulation environment, EnergyPlus, a new...

Zhou, Y.; Wu, J.; Wang, R.; Shiochi, S.

2006-01-01T23:59:59.000Z

17

Solutions for Summer Electric Power Shortages: Demand Response andits Applications in Air Conditioning and Refrigerating Systems  

SciTech Connect (OSTI)

Demand response (DR) is an effective tool which resolves inconsistencies between electric power supply and demand. It further provides a reliable and credible resource that ensures stable and economical operation of the power grid. This paper introduces systematic definitions for DR and demand side management, along with operational differences between these two methods. A classification is provided for DR programs, and various DR strategies are provided for application in air conditioning and refrigerating systems. The reliability of DR is demonstrated through discussion of successful overseas examples. Finally, suggestions as to the implementation of demand response in China are provided.

Han, Junqiao; Piette, Mary Ann

2007-11-30T23:59:59.000Z

18

2014-06-23 Issuance: Energy Conservation Standards for Walk-in Coolers and Freezers; Air-Conditioning, Heating, & Refrigeration Institute Petition for Reconsideration  

Broader source: Energy.gov [DOE]

This document is the agency response to the Energy Conservation Standards for Walk-in Coolers and Freezers; Air-Conditioning, Heating, & Refrigeration Institute Petition for Reconsideration.

19

NREL's Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants (Fact Sheet)  

SciTech Connect (OSTI)

This fact sheet describes how the DEVAP air conditioner was invented, explains how the technology works, and why it won an R&D 100 Award. Desiccant-enhanced evaporative (DEVAP) air-conditioning will provide superior comfort for commercial buildings in any climate at a small fraction of the electricity costs of conventional air-conditioning equipment, releasing far less carbon dioxide and cutting costly peak electrical demand by an estimated 80%. Air conditioning currently consumes about 15% of the electricity generated in the United States and is a major contributor to peak electrical demand on hot summer days, which can lead to escalating power costs, brownouts, and rolling blackouts. DEVAP employs an innovative combination of air-cooling technologies to reduce energy use by up to 81%. DEVAP also shifts most of the energy needs to thermal energy sources, reducing annual electricity use by up to 90%. In doing so, DEVAP is estimated to cut peak electrical demand by nearly 80% in all climates. Widespread use of this cooling cycle would dramatically cut peak electrical loads throughout the country, saving billions of dollars in investments and operating costs for our nation's electrical utilities. Water is already used as a refrigerant in evaporative coolers, a common and widely used energy-saving technology for arid regions. The technology cools incoming hot, dry air by evaporating water into it. The energy absorbed by the water as it evaporates, known as the latent heat of vaporization, cools the air while humidifying it. However, evaporative coolers only function when the air is dry, and they deliver humid air that can lower the comfort level for building occupants. And even many dry climates like Phoenix, Arizona, have a humid season when evaporative cooling won't work well. DEVAP extends the applicability of evaporative cooling by first using a liquid desiccant-a water-absorbing material-to dry the air. The dry air is then passed to an indirect evaporative cooling stage, in which the incoming air is in thermal contact with a moistened surface that evaporates the water into a separate air stream. As the evaporation cools the moistened surface, it draws heat from the incoming air without adding humidity to it. A number of cooling cycles have been developed that employ indirect evaporative cooling, but DEVAP achieves a superior efficiency relative to its technological siblings.

Not Available

2012-07-01T23:59:59.000Z

20

US Department of Energys Regulatory Negotiations Convening on Commercial Certification for Heating, Ventilating, Air-Conditioning, and Refrigeration Equipment  

Broader source: Energy.gov [DOE]

This document provides Public Information for Convening Interviews for US Department of Energys Regulatory Negotiations Convening on Commercial Certification for Heating, Ventilating, Air-Conditioning, and Refrigeration Equipment

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

The Technical and Economical Analysis of a Centralized Air-Conditioning System with Cold Storage Refrigeration in High-Rise Residential Buildings  

E-Print Network [OSTI]

In recent years, the application of a centralized air-conditioning system (CACS) with cold storage refrigeration in high-rise residential buildings has gradually increased. Due to the large difference between civil residential buildings...

Xiang, C.; Xie, G.

2006-01-01T23:59:59.000Z

22

Comment submitted by the Air Conditioning, Heating and Refrigeration Institute (AHRI) regarding the Energy Star Verification Testing Program  

Broader source: Energy.gov (indexed) [DOE]

AHRI Comments - DOE Verification Testing in Support of Energy Star AHRI Comments - DOE Verification Testing in Support of Energy Star May 9, 2011 P a g e | 1 May 9, 2010 Ms. Ashley Armstrong U.S. Department of Energy 1000 Independence Avenue, SW Washington, DC 20585 RE: DOE Verification Testing in Support of Energy Star Dear Ms. Armstrong: I am writing on behalf of the Air Conditioning, Heating and Refrigeration Institute (AHRI) to address the proposed DOE requirements for verification testing in support of the Energy Star program. AHRI is the trade association representing manufacturers of heating, cooling, and commercial refrigeration equipment. More than 300 members strong, AHRI is an internationally recognized advocate for the industry, and develops standards for and certifies the performance of many of the

23

Research Positionsfor Development of Novel Green Air Conditioning and Refrigeration Systems for Transportation Vehicles  

E-Print Network [OSTI]

in refrigeration and heat pump systems, HVAC, porous media development/characterization, transport phenomena of compact and lightweight heat exchangers for evaporator and condenser; v) Development of heatdriven adsorption chillers tailored to service vehicles; vi) Development and implementation of thermal energy

Bahrami, Majid

24

Memorandum To: GENERAL COUNSEL, DEPARTMENT OF ENERGY (DOE) From: JONATHAN MELCHI, HEATING, AIR-CONDITIONING AND REFRIGERATION  

Broader source: Energy.gov (indexed) [DOE]

To: GENERAL COUNSEL, DEPARTMENT OF ENERGY (DOE) To: GENERAL COUNSEL, DEPARTMENT OF ENERGY (DOE) From: JONATHAN MELCHI, HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL (HARDI) Date: 1/12/2012 Subject: EX PARTE COMMUNICATION MEMO DOE ATTENDEES: Ashley Armstrong, John Cymbalsky, David Case, Laura Barhydt HARDI ATTENDEES: Talbot Gee, Jonathan Melchi AREAS OF DISCUSSION: DOE Framework Document and Stakeholder Meeting regarding the Enforcement of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps. The meeting took place on Thursday January 5 th , 2012 from 2pm to 3-pm. The following topics were discussed. 1.) Sell-Through. HARDI asked for clarification on the DOE's notation on the Framework Document

25

Air Conditioning  

Science Journals Connector (OSTI)

Air Conditioning ... CHEMISTS and engineers use air conditioning as a valuable tool in more than two hundred industries. ... Air conditioning is a tool with many facets. ...

MARGARET INGELS

1938-02-10T23:59:59.000Z

26

Experimental Tests and Predictive Model of an Adsorptive Air Conditioning Unit  

Science Journals Connector (OSTI)

An adsorption air conditioning unit has been built operating with a heat and mass recovery cycle and a zeolite?water pair. A new consolidated adsorbent composite with good heat transfer properties has been developed and implemented in the adsorber. At an ...

Florence Poyelle; Jean-Jacques Guilleminot; Francis Meunier

1998-12-08T23:59:59.000Z

27

2014-02-07 Issuance: Certification of Commercial Heating, Ventilation, and Air-conditioning, Water Heating, and Refrigeration Equipment; Notice of Proposed Rulemaking  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of proposed rulemaking regarding certification of commercial heating, ventilation, and air-conditioning, water-heating, and refrigeration equipment, as issued by the Deputy Assistant Secretary for Energy Efficiency on February 7, 2014.

28

Retrofitting Inefficient Rooftop Air-Conditioning Units Reduces U.S. Navy Energy Use (Fact Sheet)  

SciTech Connect (OSTI)

As part of the U.S. Navy's overall energy strategy, the National Renewable Energy Laboratory (NREL) partnered with the Naval Facilities Engineering Command (NAVFAC) to demonstrate market-ready energy efficiency measures, renewable energy generation, and energy systems integration. One such technology - retrofitting rooftop air-conditioning units with an advanced rooftop control system - was identified as a promising source for reducing energy use and costs, and can contribute to increasing energy security.

Not Available

2014-04-01T23:59:59.000Z

29

Innovative Method for Performance Inspections often save 20-30% through Optimization of Air-Conditioning and Refrigeration  

E-Print Network [OSTI]

of performance?. (Nordtest.) Esbo, Finland. 16. NT VVS 116, 1997. ?Refrigeration and heat pump equipment: Check-ups and performance data inferred from measurements under field conditions in the refrigerant system?. (Nordtest.) Esbo, Finland. ESL-IC-10...

Berglof, K.

2010-01-01T23:59:59.000Z

30

"Table HC3.7 Air-Conditioning Usage Indicators by Owner-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air-Conditioning Usage Indicators by Owner-Occupied Housing Unit, 2005" 7 Air-Conditioning Usage Indicators by Owner-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ,"U.S. Housing Units (millions)" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Air Conditioning Usage Indicators",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Do Not Have Cooling Equipment",17.8,11.3,9.3,0.6,"Q",0.4,0.9 "Have Cooling Equipment",93.3,66.8,54.7,3.6,1.7,1.9,4.8 "Use Cooling Equipment",91.4,65.8,54,3.6,1.7,1.9,4.7

31

"Table HC3.6 Air Conditioning Characteristics by Owner-Occupied Housing Units, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

6 Air Conditioning Characteristics by Owner-Occupied Housing Units, 2005" 6 Air Conditioning Characteristics by Owner-Occupied Housing Units, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ,"U.S. Housing Units (millions" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Air Conditioning Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Do Not Have Cooling Equipment",17.8,11.3,9.3,0.6,"Q",0.4,0.9 "Have Cooling Equipment",93.3,66.8,54.7,3.6,1.7,1.9,4.8 "Use Cooling Equipment",91.4,65.8,54,3.6,1.7,1.9,4.7

32

Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate Filters Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate...

33

US Department of Energys Regulatory Negotiations Convening on Commercial Certification for Heating, Ventilating, Air-Conditioning, and Refrigeration Equipment  

Broader source: Energy.gov (indexed) [DOE]

US Department of Energy's Regulatory Negotiations Convening on US Department of Energy's Regulatory Negotiations Convening on Commercial Certification for Heating, Ventilating, Air-Conditioning, and Refrigeration Equipment Public Information for Convening Interviews I. What are the substantive issues DOE seeks to address? Strategies for grouping various basic models for purposes of certification; Identification of non-efficiency attributes, which do not impact the measured consumption of the equipment as tested by DOE's test procedure; The information that is certified to the Department; The timing of when the certification should be made relative to distribution in commerce; and Alterations to a basic model that would impact the certification.

34

2014-09-23 Issuance: Energy Conservation Standard for Walk-in Coolers and Freezers; Air-Conditioning, Heating, & Refrigeration Institute Petition for Reconsideration Notice of Public Meeting  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of public meeting regarding energy conservation standards for walk-in coolers and freezers; Air-Conditioning, Heating, & Refrigeration Institute petition for reconsideration, as issued by the Deputy Assistant Secretary for Energy Efficiency on September 23, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

35

Assessment of adsorber bed designs in waste-heat driven adsorption cooling systems for vehicle air conditioning and refrigeration  

E-Print Network [OSTI]

Assessment of adsorber bed designs in waste-heat driven adsorption cooling systems for vehicle air conditioning Finned tube adsorber bed Specific cooling power Adsorber bed to adsorbent mass ratio a b s t r a c t Adsorber bed design strongly affects the performance of waste-heat driven adsorption cooling systems (ACS

Bahrami, Majid

36

INSTALLATION CERTIFICATE CF-6R-MECH-08 Ice Storage Air Conditioning (ISAC) Units (Page 1 of 2)  

E-Print Network [OSTI]

cooling with the compressor). Yes No #12;INSTALLATION CERTIFICATE CF-6R-MECH-08 Ice Storage AirINSTALLATION CERTIFICATE CF-6R-MECH-08 Ice Storage Air Conditioning (ISAC) Units (Page 1 of 2) Site Address: Enforcement Agency: Permit Number: 2008 Residential Compliance Forms August 2009 Ice Storage Air

37

E-Print Network 3.0 - air-conditioning system driven Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

(3-0-3) Summary: and design of air-conditioning, heating, and refrigeration systems; including consideration of vapor... ME 4321 Refrigeration and Air Conditioning...

38

Relationship between the merit factor of thermoelectric materials and the air conditioning unit of urban electric cars  

SciTech Connect (OSTI)

The main benefit of electric cars is to reduce air pollution in cities that is thus desirable to equip them with non polluting air conditioning units and this rules out frigorific compressors operating with CFC. The planned replacement of CFC by HFC is at best an interim solution. The best solution is certainly to use thermoelectric air conditioning units, which are inherently pollution-free. However, these have a fairly low COPF when compared to traditional compressor units. We study the relationship between the cooling of the interior of urban electric cars and the merit factor of the thermoelectric material in their Peltier unit. This should help provide concrete target properties of future T E materials. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

Buffet, J. [Counsulting Engineer, 2 av. DODE de la BRUNERIE 75016 Paris (France)

1994-08-10T23:59:59.000Z

39

NRELs Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants (Fact Sheet), NREL (National Renewable Energy Laboratory)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DEVAP Slashes Peak Power Loads DEVAP Slashes Peak Power Loads Desiccant-enhanced evaporative (DEVAP) air-condi- tioning will provide superior comfort for commercial buildings in any climate at a small fraction of the elec- tricity costs of conventional air-conditioning equip- ment, releasing far less carbon dioxide and cutting costly peak electrical demand by an estimated 80%. Air conditioning currently consumes about 15% of the electricity generated in the United States and is a major contributor to peak electrical demand on hot summer days, which can lead to escalating power costs, brownouts, and rolling blackouts. DEVAP employs an innovative combination of air-cooling technologies to reduce energy use by up to 81%. DEVAP also shifts most of the energy needs to thermal energy sources, reducing annual electricity use by up

40

Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit  

Science Journals Connector (OSTI)

Abstract The recently-built school buildings have adopted novel heat recovery ventilator and air conditioning system. Heat recovery efficiency of the heat recovery facility and energy conservation ratio of the air conditioning unit were analytically modeled, taking the ventilation networks into account. Following that, school classroom displacement ventilation and its thermal stratification and indoor air quality indicated by the CO2 concentration have been numerically modeled concerning the effects of delivering ventilation flow rate and supplying air temperature. Numerical results indicate that the promotion of mechanical ventilation rate can simultaneously boost the dilution of indoor air pollutants and the non-uniformity of indoor thermal and pollutant distributions. Subsequent energy performance analysis demonstrates that classroom energy demands for ventilation and cooling could be reduced with the promotion of heat recovery efficiency of the ventilation facility, and the energy conservation ratio of the air conditioning unit decreases with the increasing temperatures of supplying air. Fitting correlations of heat recovery ventilation and cooling energy conservation have been presented.

Yang Wang; Fu-Yun Zhao; Jens Kuckelkorn; Di Liu; Li-Qun Liu; Xiao-Chuan Pan

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Case Study: The Effective Use of an Extensive Logical rule Based Data Analytics Approach in Establishing Root Cause of Performance Issues in Widespread Deployments of Unitary Space Air Conditioning Units  

E-Print Network [OSTI]

Today a significant percentage of office spaces are air conditioned using widely deployed unitary systems, either Fan Coil Units (FCU) or Variable Air Volume (VAV) boxes, to achieve high degrees of air conditioned zonal control. However establishing...

Brady, N.

2013-01-01T23:59:59.000Z

42

Air-Conditioning Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air-Conditioning Basics Air-Conditioning Basics Air-Conditioning Basics August 16, 2013 - 1:59pm Addthis Air conditioning is one of the most common ways to cool homes and buildings. How Air Conditioners Work Air conditioners employ the same operating principles and basic components as refrigerators. Refrigerators use energy (usually electricity) to transfer heat from the cool interior of the refrigerator to the relatively warm surroundings; likewise, an air conditioner uses energy to transfer heat from the interior space to the relatively warm outside environment. An air conditioner uses a cold indoor coil called the evaporator. The condenser, a hot outdoor coil, releases the collected heat outside. The evaporator and condenser coils are serpentine tubing surrounded by aluminum fins. This tubing is usually made of copper.

43

E-Print Network 3.0 - air conditioning maintenance Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Last Updated: 41702 Summary: , including refrigeration, air conditioning, heating systems, ventilating fans, roof ventilators, exhaust fans... : Use of mechanical equipment...

44

Indoor air environment and night cooling energy efficiency of a southern German passive public school building operated by the heat recovery air conditioning unit  

Science Journals Connector (OSTI)

Abstract The recently built school building has adopted a novel heat recovery air conditioning system. Heat recovery efficiency of the heat recovery facility and energy conservation ratio of the air conditioning unit were analytically modeled, taking the ventilation networks into account. Following that, school classroom displacement ventilation and its thermal stratification have been numerically investigated concerning the effects of the heat flow flux of passive cooling within the ceiling concrete in the classroom due to night ventilation in summer which could result in cooling energy storage. Numerical results indicate that the promotion of passive cooling can simultaneously decrease the volume averaged indoor temperatures and the non-uniformity of indoor thermal distributions. Subsequent energy performance analysis demonstrates that classroom energy demands for ventilation and cooling could be reduced with the promotion of heat recovery efficiency of the ventilation facility, and the energy conservation ratio of the air-cooling unit decreases with the increasing temperatures of exhaust air and the heat flux value for passive cooling within the classroom ceiling concrete. Fitting correlations of heat recovery ventilation and cooling energy conservation have been presented.

Yang Wang; Fu-Yun Zhao; Jens Kuckelkorn; Xiao-Hong Li; Han-Qing Wang

2014-01-01T23:59:59.000Z

45

Liquid over-feeding air conditioning system and method  

DOE Patents [OSTI]

A refrigeration air conditioning system utilizing a liquid over-feeding operation is described. A liquid refrigerant accumulator-heat exchanger is placed in the system to provide a heat exchange relationship between hot liquid refrigerant discharged from condenser and a relatively cool mixture of liquid and vaporous refrigerant discharged from the evaporator. This heat exchange relationship substantially sub-cools the hot liquid refrigerant which undergoes little or no evaporation across the expansion device and provides a liquid over-feeding operation through the evaporator for effectively using 100 percent of evaporator for cooling purposes and for providing the aforementioned mixture of liquid and vaporous refrigerant. 1 figure.

Mei, V.C.; Chen, F.C.

1993-09-21T23:59:59.000Z

46

E-Print Network 3.0 - air conditioning hvac Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

systems play an important role in providing comfort in residential, commercial... of Heating, Refrigerating, and Air-Conditioning Engineers. Batterman S. and Burge H. 1995. "HVAC...

47

E-Print Network 3.0 - air-conditioning systems based Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

INVENTION, APPLICATION NO. 61297,958 OF 25 JAN 2010 Summary: for Efficient Heating, Cooling, Refrigeration, and Air Conditioning BY MILIVOJE M. KOSTIC, SYCAMORE, IL......

48

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network [OSTI]

RefrigerationRefrigerationRefrigeration coursecourse # 424503.0# 424503.0 v.v. 20122012 8. Heat pumps, heat pipes, cold thermal energy storage Ron on a vapour-compression cycle) /heat_pump.g Heat pumps make use of low- temperature (waste) heat, replacing/vcmfiles/ electricity!) for heating and air conditioning purposes Heat pumps became popular in ://www.bge.c Heat pumps

Zevenhoven, Ron

49

Waste Heat Powered Ammonia Absorption Refrigeration Unit for LPG Recovery  

SciTech Connect (OSTI)

An emerging DOE-sponsored technology has been deployed. The technology recovers light ends from a catalytic reformer plant using waste heat powered ammonia absorption refrigeration. It is deployed at the 17,000 bpd Bloomfield, New Mexico refinery of Western Refining Company. The technology recovers approximately 50,000 barrels per year of liquefied petroleum gas that was formerly being flared. The elimination of the flare also reduces CO2 emissions by 17,000 tons per year, plus tons per year reductions in NOx, CO, and VOCs. The waste heat is supplied directly to the absorption unit from the Unifiner effluent. The added cooling of that stream relieves a bottleneck formerly present due to restricted availability of cooling water. The 350oF Unifiner effluent is cooled to 260oF. The catalytic reformer vent gas is directly chilled to minus 25oF, and the FCC column overhead reflux is chilled by 25oF glycol. Notwithstanding a substantial cost overrun and schedule slippage, this project can now be considered a success: it is both profitable and highly beneficial to the environment. The capabilities of directly-integrated waste-heat powered ammonia absorption refrigeration and their benefits to the refining industry have been demonstrated.

Donald C, Energy Concepts Co.; Lauber, Eric, Western Refining Co.

2008-06-20T23:59:59.000Z

50

Solar Heating and Air Conditioning  

Science Journals Connector (OSTI)

...given of the status of solar fired air conditioning...to an approach to cool storage in solar air conditioning systems...an assessment of cool storage for reducing peak electrical...rolling cylinder thermal energy storage device for compact...

1980-01-01T23:59:59.000Z

51

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Broader source: Energy.gov (indexed) [DOE]

Desiccant Enhanced Evaporative Air Conditioning Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system. DEVAP uses 90 percent less electricity and up to 80 percent less

52

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Broader source: Energy.gov (indexed) [DOE]

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system.

53

Air Conditioning | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Conditioning Conditioning Air Conditioning July 1, 2012 - 6:28pm Addthis Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ©iStockphoto/JaniceRichard Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ©iStockphoto/JaniceRichard How does it work? An air conditioner uses energy -- usually electricity -- to transfer heat from the interior of your home to the relatively warm outside environment. Two-thirds of all homes in the United States have air conditioners. Air conditioners use about 5% of all the electricity produced in the United States, at an annual cost of more than $11 billion to homeowners. As a

54

High Energy Efficiency Air Conditioning  

SciTech Connect (OSTI)

This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these values agree well with previous results and computer simulations of Ikon B performance versus R-22. The lower cooling capacity of Ikon B is not a concern unless a particular air conditioner is near its maximum cooling capacity in application. Typically, oversized A/C systems are installed by contractors to cover contingencies. In the extended run with Ikon B, which lasted about 4.5 months at 100 deg F ambient temperature and 68% compressor on time, the air conditioner performed well with no significant loss of energy efficiency. Post-run analysis of the refrigerant, compressor lubricant oil, compressor, compressor outlet tubing, and the filter/dryer showed minor effects but nothing that was considered significant. The project was very successful. All objectives were achieved, and the performance of Ikon B indicates that it can easily be retrofitted into R-22 air conditioners to give 15 - 20% energy savings and a 1 - 3 year payback of retrofit costs depending on location and use. Ikon B has the potential to be a successful commercial product.

Edward McCullough; Patrick Dhooge; Jonathan Nimitz

2003-12-31T23:59:59.000Z

55

ARTI refrigerant database  

SciTech Connect (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M.

1996-11-15T23:59:59.000Z

56

Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line  

DOE Patents [OSTI]

The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.

Gaul, Christopher J. (Thornton, CO)

2001-01-01T23:59:59.000Z

57

Heating, Ventilation and Air Conditioning Efficiency  

Broader source: Energy.gov (indexed) [DOE]

Presented By: WALTER E. JOHNSTON, PE Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE Air Conditioning (HVAC) system is to provide and maintain a comfortable environment within a building for the occupants or for the process being conducted Many HVAC systems were not designed with energy efficiency as one of the design factors 3 Air Air is the major conductor of heat. Lack of heat = air conditioning OR 4 Btu - Amount of heat required to raise one pound of water 1 F = 0.252 KgCal 1 Pound of Water = About 1 Pint of Water ~ 1 Large Glass 1 Kitchen Match Basics of Air Conditioning = 1 Btu 5 = 6 Low Cost Cooling Unit 7 8 Typical Design Conditions 75 degrees F temperature 50% relative humidity 30 - 50 FPM air movement

58

NREL: Vehicle Ancillary Loads Reduction - Air Conditioning and Emissions  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Conditioning and Emissions Conditioning and Emissions Air conditioning and indirect emissions go together in the sense that when a vehicle's air conditioning system is in use, fuel economy declines. When more petroleum fuel is burned, more pollution and greenhouse gases are emitted. An additional, "direct" source of greenhouse gas emissions is the refrigerant used in air conditioning. Called HFC-134a, this pressurized gas tends to seep through tiny openings and escapes into the atmosphere. It can also escape during routine service procedures such as system recharging. NREL's Vehicle Ancillary Loads Reduction team applied its vehicle systems modeling expertise in a study to predict fuel consumption and indirect emissions resulting from the use of vehicle air conditioning. The analysis

59

Alternative non-CFC mobile air conditioning  

SciTech Connect (OSTI)

Concern about the destruction of the global environment by chlorofluorocarbon (CFC) fluids has become an impetus in the search for alternative, non-CFC refrigerants and cooling methods for mobile air conditioning (MAC). While some alternative refrigerants have been identified, they are not considered a lasting solution because of their high global warming potential, which could result in their eventual phaseout. In view of this dilemma, environmentally acceptable alternative cooling methods have become important. This report, therefore, is aimed mainly at the study of alternative automotive cooling methodologies, although it briefly discusses the current status of alternative refrigerants. The alternative MACs can be divided into work-actuated and heat-actuated systems. Work-actuated systems include conventional MAC, reversed Brayton air cycle, rotary vane compressor air cycle, Stirling cycle, thermoelectric (TE) cooling, etc. Heat-actuated MACs include metal hydride cooling, adsorption cooling, ejector cooling, absorption cycle, etc. While we are better experienced with some work-actuated cycle systems, heat-actuated cycle systems have a high potential for energy savings with possible waste heat applications. In this study, each altemative cooling method is discussed for its advantages and its limits.

Mei, V.C.; Chen, F.C.; Kyle, D.M.

1992-09-01T23:59:59.000Z

60

Natural Air-Conditioning Systems  

Science Journals Connector (OSTI)

Recent research in summer air conditioning utilizing natural sources of coolness* are discussed. These systems are classified according to the sources of coolness, the modes of heat transfer and airflow, and t...

Mehdi N. Bahadori

1986-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)  

SciTech Connect (OSTI)

This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

Kozubal, E.

2013-02-01T23:59:59.000Z

62

Section 38 - HVAC (Heating, Ventilation, Air Conditioning)  

Science Journals Connector (OSTI)

The term HVAC is an acronym for Heating, Ventilation (and) Air Conditioning, the industry term for any of various efforts to control conditions in a building or other enclosed area to improve comfort and efficiency. A closely related section is Refrigeration, which follows this one. Some contemporary HVAC techniques have ancient roots. Early forms of central heating and solar home heating were in use in Rome in the first century A.D. The earliest use of glass in windows (as opposed to a covering of wood, cloth, or hide, or simply an opening) is also attributed to the Romans at this same time. The first known use of solar-oriented building design in North America dates back to about the year 1050; i.e., the cliff dwellings built by the Anasazi (Ancient Pueblo) people of the Colorado Plateau area. Geothermal district heating was employed as early as the 1300s, in the Auvergne region of southern France. The foundation for modern central heating was established in the 1700s, first in England and then in France. The 1800s saw significant advances in the use of water heaters, especially the first automatic storage water heater (Edwin Ruud, 1889) and the first commercial solar water heater (Clarence Kemp, 1891). In comparison with heating, cooling technology was late in developing. The first successful method of producing ice occurred in 1851, and it was not until 1902 that Willis Haviland Carrier designed the first industrial air-conditioning system. His Carrier Air Conditioning Corporation would go on to develop air-conditioning systems for stores and theaters (1924) and for residential buildings (1928). Carrier remains the global leader in air conditioner production. The first air-conditioned automobile was produced by Packard in 1939. Recent entries in this section emphasize the use of alternative energy sources in heating and cooling, such as solar, photovoltaic, geothermal, and fuel cells. These advances include the ground-source heat pump, the Trombe wall, the heat pipe, and the PV/thermal hybrid system.

Cutler J. Cleveland; Christopher Morris

2014-01-01T23:59:59.000Z

63

Greenhouse Gas Emissions for Refrigerant Choices in Room Air Conditioner Units  

Science Journals Connector (OSTI)

In this work, potential replacement refrigerants for window-mounted room air conditioners (RACs) in the U.S. have been evaluated using a greenhouse gas (GHG) emissions analysis. ... De Kleine, R. D.; Keoleian, G. A.; Kelly, J. C.Optimal replacement of residential air conditioning equipment to minimize energy, greenhouse gas emissions, and consumer cost in the US Energy Policy 2011, 39, 3144– 3153 ... Most of the inventory data have been collected from Thailand, except for the upstream of fuel oil and fuel transmission, which have been computed from Greenhouse gases, Regulated Emissions, and Energy use in Transportation version 1.7 and Global Emission Model for Integrated Systems version 4.3. ...

Michael D. Galka; James M. Lownsbury; Paul Blowers

2012-11-08T23:59:59.000Z

64

Approaches to Selecting Design Temperatures for Air-Conditioning  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Approaches to Selecting Design Temperatures for Air-Conditioning Approaches to Selecting Design Temperatures for Air-Conditioning Speaker(s): Eric Peterson Date: July 7, 2005 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves Edward A. Arens The presentation will describe and compare the methods of determining cooling design conditions used by ASHRAE and the Australian Institute of Refrigeration, Air-Conditioning and Heating. A case study based on weather data for Brisbane will be used to illustrate the issues that arise. One issue is the usefulness of the 3-hourly temperature observations archived in International Weather Office records compared to the hourly observations required by the ASHRAE method. Another issue is the use of daily maxima, which have been archived for over 100 years at many Australian locations. Daily data can easily be used to find trends

65

Thermoacoustic refrigerators and engines comprising cascading stirling thermodynamic units  

DOE Patents [OSTI]

The present invention includes a thermoacoustic assembly and method for improved efficiency. The assembly has a first stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator and at least one additional heat exchanger. The first stage Stirling thermal unit is serially coupled to a first end of a quarter wavelength long coupling tube. A second stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator, and at least one additional heat exchanger, is serially coupled to a second end of the quarter wavelength long coupling tube.

Backhaus, Scott; Swift, Greg

2013-06-25T23:59:59.000Z

66

A New Approach to Industrial Air Conditioning  

E-Print Network [OSTI]

-dryer Systems Division, has marketed industrial drying machinery. These heat reactivated dryers can handle latent loads in industrial air conditioning systems. Through waste heat conservation, air conditioning costs can be reduced 25 to 50%, with applications...

Gravenstreter, T.

1982-01-01T23:59:59.000Z

67

ARTI refrigerant database  

SciTech Connect (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates. Citations in this report are divided into the following topics: thermophysical properties; materials compatibility; lubricants and tribology; application data; safety; test and analysis methods; impacts; regulatory actions; substitute refrigerants; identification; absorption and adsorption; research programs; and miscellaneous documents. Information is also presented on ordering instructions for the computerized version.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)] [Calm (James M.), Great Falls, VA (United States)

1996-04-15T23:59:59.000Z

68

HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL...  

Broader source: Energy.gov (indexed) [DOE]

of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps. DOE EX Parte Memo.pdf More Documents & Publications 3rd Semi-Annual Report to...

69

HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL (HARDI)  

Broader source: Energy.gov [DOE]

OE Framework Document and Stakeholder Meeting regarding the Enforcement of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps.

70

Thermodynamic Evaluation of Low-Global-Warming-Potential Refrigerants...  

Broader source: Energy.gov (indexed) [DOE]

Impact This will provide the heating, venting, air conditioning, and refrigeration (HVAC&R) industries and policymakers with definitive information regarding the available...

71

ENSC 461 PROJECT: Next generation air conditioning systems for vehicles Assigned date: Feb. 21, 2011 Due date: April 11, 2011  

E-Print Network [OSTI]

to significant power consumption of vapour-compression systems, finding a new "green" refrigerant is another vehicles (HEVs), as it is the second most energy consuming system after the electric motor. Further, HVAC air conditioning systems used in the automotive industry are based on vapour-compression refrigeration

Bahrami, Majid

72

Central Air Conditioning | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Central Air Conditioning Central Air Conditioning Central Air Conditioning May 30, 2012 - 8:01pm Addthis Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ©iStockphoto/DonNichols. Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ©iStockphoto/DonNichols. What does this mean for me? Central air conditioning systems are thermostatically controlled and convenient to use. Central air conditioning systems must be installed properly to operate efficiently. Central air conditioning systems can share ductwork with your heating system. Central air conditioners circulate cool air through a system of supply and return ducts. Supply ducts and registers (i.e., openings in the walls,

73

Energy-efficient heat recovery systems for air conditioning of indoor swimming pools  

SciTech Connect (OSTI)

Analysis of a conventional air-conditioning system for indoor swimming pools during the summer season is presented. The analysis showed that the cooling load is characterized by a large latent heat fraction. As a result, a reheating process must be used downstream of the cooling coil to achieve the proper design comfort condition in the pool area. This, in turn, increases the energy requirement per unit cooling load of the pool. Two heat recovery systems are proposed to reduce this energy. In the first system, ambient air is used for the reheating process in an air-to-air heat exchanger. In the second system, mixed air--recirculated and ambient air--is used for the reheating process. Heat recovery efficiency is defined as an index of the energy savings resulting from the use of the heat recovery system compared to that of a conventional air-conditioning system. At a wide range of ambient conditions it is found that the energy savings could be up to 70% of the energy required to operate a conventional air-conditioning system. A parametric study was carried out to size the air-to-air heat exchanger associated with these heat recovery systems, and the results showed that a heat exchanger having an effectiveness of 0.5 would give satisfactory results. The proposed heat recovery systems are also compared to the case of reheating using the heat rejection from the condenser of the refrigeration machine. The comparison showed that the proposed systems save more energy than reheating using the condenser heat. A typical case study is given to demonstrate the savings in energy consumption when these systems are used.

Elsayed, M.M.; El-Refaee, M.M. [Kuwait Univ., Safat (Kuwait). Mechanical Engineering Dept.; Borhan, Y.A. [Gulf Engineering Co., Safat (Kuwait)

1997-12-31T23:59:59.000Z

74

ARTI Refrigerant Database  

SciTech Connect (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on R-32, R-123, R-124, R- 125, R-134a, R-141b, R142b, R-143a, R-152a, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses polyalkylene glycol (PAG), ester, and other lubricants. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits.

Calm, J.M.

1992-04-30T23:59:59.000Z

75

Save with Hybrid Refrigeration  

E-Print Network [OSTI]

SAVE WITH HYBRID REFRIGERATION Cheng-Wen (Wayne) Chung, P.E. Fluor Engineers, Inc. Irvine, California ABSTRACT Two level demand makes it possible to use two systems for refrigeration and save energy and money. An example of this type... of refrigeration, consisting of an ammonia absorption refrigeration (AAR) unit and a mechanical compression refrigera tion (MCR) unit, is presented in this article. This paper will briefly describe process configur ation, advantages and utility consumption...

Chung, C. W.

76

Alternatives to Electric Air Conditioning Systems  

E-Print Network [OSTI]

The rapid escalation of electricity prices has created an opportunity to re-introduce gas-fired air conditioning systems to the commercial building market. In 1985 Gas Research Institute initiated a program to develop an advanced gas engine...

Lindsay, B. B.; Koplow, M. D.

1988-01-01T23:59:59.000Z

77

Changing patterns of air conditioning in Japan  

Science Journals Connector (OSTI)

Japanese air conditioning patterns have changed significantly over the past 30 years. The changes can be linked to increasing affluence and the consequent changes Japanese life patterns, but also to changes in...

Harold Wilhite; Hidetoshi Nakagami…

1999-01-01T23:59:59.000Z

78

APPLIANCE EFFICIENCY REGULATIONS FOR REFRIGERATORS AND FREEZERS  

E-Print Network [OSTI]

mobile equipment. (c) Central air conditioning heat pumps, regardless of capacity, except that requirements for central air conditioning heat pumps with cooling capacity of 135,000 Btu per hour or more#12;#12;APPLIANCE EFFICIENCY REGULATIONS FOR REFRIGERATORS AND FREEZERS ROOM AIR CONDITIONERS

79

Energy audit case studies II—air conditioning (cooling) systems  

Science Journals Connector (OSTI)

This paper discusses a novel methodology for determination of the efficiencies of each segment in a centralized air conditioning (A/C) plant. The methodology is useful analytical tool in energy audit where it can be used for decision support for evolution of energy conservation measures and techno-economic evaluation of the various options. The procedure is applied to three A/C plants of capacity range from 50 to 500 TR. Losses in chilled air ducts and cycling losses in the refrigerant circuit are identified to be the major causes for decrease in the efficiency and capacity under rating of the systems. Effective controls and insulation of air ducts: have been shown to be the most cost effective solutions to improve the energy efficiency of the A/C plants. The generalized experimental data on overall performance of sixteen A/C plants is also provided.

M Siddhartha Bhatt

2000-01-01T23:59:59.000Z

80

Solar air-conditioning-active, hybrid and passive  

SciTech Connect (OSTI)

After a discussion of summer air conditioning requirements in the United States, active, hybrid, and passive cooling systems are defined. Active processes and systems include absorption, Rankine cycle, and a small variety of miscellaneous systems. The hybrid solar cooling and dehumidification technology of desiccation is covered as well as evaporative cooling. The passive solar cooling processes covered include convective, radiative and evaporative cooling. Federal and state involvement in solar cooling is then discussed. (LEW)

Yellott, J. I.

1981-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

China Refrigerator Information Label: Specification Development and Potential Impact  

E-Print Network [OSTI]

years. About 20% of refrigerators and freezers sold in 2000energy efficiency of refrigerators and freezers, Directiveof Energy, for refrigerators and freezers are base unit

Fridley, David

2008-01-01T23:59:59.000Z

82

ETME 422 -REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC -10:00 -10:50am M W F RH 312  

E-Print Network [OSTI]

-1209(h) Office Hours: M-F 1-2p.m. Text: Heating, Ventilating, and Air Conditioning - Analysis and Design. -- Refrigeration and heating, ventilating and air-conditioning (HVAC) for comfort and industrial applications of the fundamentals of Heating, Ventilating, Air Conditioning, and Refrigeration as they relate to human comfort

Dyer, Bill

83

Some studies on industrial Refrigeration system integrated With encapsulated pcm in cool Thermal energy storage system;.  

E-Print Network [OSTI]

??The widespread use of refrigeration and air conditioning utilities newlineespecially in the developing countries has increased manifold during the last newlinedecade This additional load on… (more)

Cheralathan M

2014-01-01T23:59:59.000Z

84

Dynamic Modeling and Cascaded Control for a Multi-Evaporator Supermarket Refrigeration System.  

E-Print Network [OSTI]

??The survey from US Department of Energy showed that about one-third of energy consumption in US is due to air conditioning and refrigeration systems. This… (more)

Gupta, Ankush 1986-

2012-01-01T23:59:59.000Z

85

Study of Low Global Warming Potential Refrigerants in Heat Pump System for Residential Applications.  

E-Print Network [OSTI]

??R410A is one of the major refrigerants used for air conditioning and heat pump systems in residential applications. It has zero ODP but its GWP… (more)

Barve, Atharva

2012-01-01T23:59:59.000Z

86

Next Generation Low-Global Warming Potential Refrigerants R&D...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

accelerate the transition to low-GWP refrigerants across the entire heating, ventilation, air-conditioning and refrigeration (HVAC&R) industry. The schedule of R&D activities...

87

Seawater Air Conditioning for Downtown Engineering Project Manager  

E-Print Network [OSTI]

Seawater Air Conditioning for Downtown Honolulu Scott Higa Engineering Project Manager Honolulu Seawater Air Conditioning, LLC Abstract As a tropical island state, Hawaii has a year-round demand for air conditioning. Conventional air conditioning systems are energy intensive and represent close to 50 percent

Frandsen, Jannette B.

88

"Table HC11.6 Air Conditioning Characteristics by Northeast Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

6 Air Conditioning Characteristics by Northeast Census Region, 2005" 6 Air Conditioning Characteristics by Northeast Census Region, 2005" " Million U.S. Housing Units" ,,"Northeast Census Region" ,"U.S. Housing Units (millions)" ,,,"Census Division" ,,"Total Northeast" "Air Conditioning Characteristics",,,"Middle Atlantic","New England" "Total",111.1,20.6,15.1,5.5 "Do Not Have Cooling Equipment",17.8,4,2.4,1.7 "Have Coolling Equipment",93.3,16.5,12.8,3.8 "Use Cooling Equipment",91.4,16.3,12.6,3.7 "Have Equipment But Do Not Use it",1.9,0.3,"Q","Q" "Air-Conditioning Equipment1, 2 " "Central System",65.9,6,5.2,0.8 "Without a Heat Pump",53.5,5.5,4.8,0.7

89

"Table HC13.6 Air Conditioning Characteristics by South Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

6 Air Conditioning Characteristics by South Census Region, 2005" 6 Air Conditioning Characteristics by South Census Region, 2005" " Million U.S. Housing Units" ,,"South Census Region" ,"U.S. Housing Units (millions)" ,,,"Census Division" ,,"Total South" "Air Conditioning Characteristics",,,"South Atlantic","East South Central","West South Central" "Total",111.1,40.7,21.7,6.9,12.1 "Do Not Have Cooling Equipment",17.8,1.4,0.8,0.2,0.3 "Have Cooling Equipment",93.3,39.3,20.9,6.7,11.8 "Use Cooling Equipment",91.4,38.9,20.7,6.6,11.7 "Have Equipment But Do Not Use it",1.9,0.5,"Q","Q","Q" "Air-Conditioning Equipment1, 2 "

90

Next Generation Rooftop Unit | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Generation Rooftop Unit A typical commercial rooftop air-conditioning unit (RTU) Credit: Oak Ridge National Lab A typical commercial rooftop air-conditioning unit (RTU) Credit:...

91

Monitoring refrigeration energy useage.  

SciTech Connect (OSTI)

Refrigerators use more energy than any other kitchen appliance -- an unsurprising fact considering that refrigerators operate 24 hours a day, 365 days a year to keep food at a safe temperature. In many low-income households, refrigerators eat up more than half the electricity consumed in one year. And if the refrigerator in a family's home is functioning poorly, the cost to the consumer can be enormous. Discovering whether an existing refrigerator is operating inefficiently enough to warrant replacing it is an extremely difficult task for a resident who sees only a monthly electric bill. Only by knowing the approximate usage of the existing unit can anyone tell whether it would pay to buy a new, energy-efficient refrigerator. The savings from replacing older refrigerators can be substantial, and collecting the data needed to determine when refrigerators should be replaced is easier and less costly than one might think. In both Chicago and New York City, replacing existing units cut refrigerator electricity usage by more than 50%. Monitoring to develop an average usage for the existing stock of refrigerators is a task that can be completed by maintenance staff in a reasonably short time -- and identifying poorly performing units that should be immediately replaced can take just two hours of monitoring.

Cavallo, J.; Mapp, J.; Energy Systems; Wisconsin Energy Bureau

2000-05-01T23:59:59.000Z

92

UNITED STATES PATENT AND TRADEMARK OFFICE PATENT-PENDING INVENTION, APPLICATION NO. 61/297,958 OF 25 JAN 2010  

E-Print Network [OSTI]

for Efficient Heating, Cooling, Refrigeration, and Air Conditioning BY MILIVOJE M. KOSTIC, SYCAMORE, IL, Refrigeration, and Air Conditioning, and set up a new paradigm in the industry. The method is suitable for Efficient Heating, Cooling, Refrigeration, and Air Conditioning BY MILIVOJE M. KOSTIC, SYCAMORE, IL

Kostic, Milivoje M.

93

Innovative Systems for Solar Air Conditioning of Buildings  

E-Print Network [OSTI]

Solar air conditioning is an attractive technology to achieve comfortable room conditions, especially in hot and sunny climates. In particular air conditioning systems based on sorption technologies offer several advantages as they can be designed...

Kessling, W.; Peltzer, M.

2004-01-01T23:59:59.000Z

94

Energy Conservation of Air Conditioning Systems in Large Public Buildings  

E-Print Network [OSTI]

with the heating characteristics of the exterior -protected construction, the set value of the temperature of the air-conditioning, the lectotype of the Central air-conditioning system, the regulation and the modification of the transmission and distribution system...

Liu, P.; Li, D.

2006-01-01T23:59:59.000Z

95

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network [OSTI]

; Gas processing (O2, H2, CO2, LPG, LNG...) (3) Air conditioning, cooling towers, rg/pages/zon Air conditioning, cooling towers, food cooling and freezing (4) Heat pumps, heat pipes, special ww.sgisland.o p p

Zevenhoven, Ron

96

1st TECCS meeting, 26th April 2007 Adsorption Refrigeration  

E-Print Network [OSTI]

TECCS meeting, 26th April 2007 Adsorption refrigerators and heat pumps These machines ADsorb cycles for: Heat pumps Refrigerators Air conditioning Driven by heat from: Fossil fuels Bio fuels Waste of concept forced convection adsorption machine [#1] · Generating temperature 225° C · Heat rejection

Davies, Christopher

97

Using Modelica for Physical Modeling of Air-Conditioning Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Using Modelica for Physical Modeling of Air-Conditioning Systems Using Modelica for Physical Modeling of Air-Conditioning Systems Speaker(s): Jonas Eborn Date: August 23, 2007 - 12:00pm Location: 90-4133 Seminar Host/Point of Contact: Michael Wetter The Air Conditioning library is a commercial Modelica library for the steady-state and transient simulation of air conditioning systems using both compact micro-channel heat exchangers as well as fin-and-tube type heat exchangers. Currently it is mostly used by automotive OEMs and suppliers that need high-accuracy system level models to evaluate energy efficiency of systems developed under the pressure of reduced design cycle times. The library also has applications in other areas, including aircraft cooling systems and residential air-conditioning. The Air Conditioning library contains published correlations for heat and mass transfer and

98

Low-GWP Refrigerants Research Project | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Emerging Technologies » Low-GWP Refrigerants Research Project Emerging Technologies » Low-GWP Refrigerants Research Project Low-GWP Refrigerants Research Project The U.S. Department of Energy is currently conducting research into low global warming potential (GWP) refrigerants. As concerns about climate change intensify, it is becoming increasingly clear that suitable low-GWP refrigerants will be needed for both new and existing residential and commercial heating, ventilation, air conditioning, and refrigeration (HVAC&R) equipment. Project Description This project seeks to develop alternative refrigerants for HVAC&R equipment. The overall environmental impacts of alternative refrigerants will be assessed using a life cycle climate performance model that accounts for direct emissions associated with refrigerant leaks and indirect

99

Chapter 7, Refrigerator Recycling Evaluation Protocol: The Uniform...  

Office of Environmental Management (EM)

of refrigerators recycled through the program EXISTINGUEC The average annual unit energy consumption of participating refrigerators PARTUSE The portion of the year the...

100

Direct Digital Control in Air Conditioning Systems for Energy Efficiency  

E-Print Network [OSTI]

the function and the level of the building, but also save energy. At present, air-conditioning design in internal commercial buildings is becoming more complex and enormous. The proportion of air conditioning systems in the whole building is getting larger...

Liu, W.; Ye, A.; Li, D.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Proceedings: commercial refrigeration research workshop. Summary  

SciTech Connect (OSTI)

The purpose of this workshop was to identify the state-of-the-art and determine research needs for improving energy use and demand in commercial refrigeration applications. Workshop attendees included research and development, technical operations and marketing people from manufacturers of supermarket refrigeration, space conditioning, and energy management systems equipment, and from supermarket chains and electric utilities. Presentations were given on best current practice and research needs from the perspective of each of these industry segments. Working groups identified ten important research, development and equipment demonstration projects to improve the efficiency of refrigerating equipment, heating, ventilating and air-conditioning (HVAC) equipment, and other energy-using systems in supermarkets.

Blatt, M.H.

1984-10-01T23:59:59.000Z

102

Innovative Evaporative and Thermally Activated Technologies Improve Air Conditioning, The Spectrum of Clean Energy Innovation (Fact Sheet)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Innovative Evaporative and Innovative Evaporative and Thermally Activated Technologies Improve Air Conditioning Researchers at the National Renewable Energy Laboratory (NREL) invented a breakthrough technology that improves air conditioning in a novel way-with heat. NREL combined desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90% less electricity and up to 80% less total energy than traditional air conditioning (AC). This solution, called the desiccant enhanced evaporative air conditioner (DEVap), also controls humidity more effectively to improve the comfort of people in buildings. Desiccants are an example of a thermally activated technology (TAT) that relies on heat instead

103

"Table HC15.6 Air Conditioning Characteristics by Four Most Populated States, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

6 Air Conditioning Characteristics by Four Most Populated States, 2005" 6 Air Conditioning Characteristics by Four Most Populated States, 2005" " Million U.S. Housing Units" ,"U.S. Housing Units (millions)","Four Most Populated States" "Air Conditioning Characteristics",,"New York","Florida","Texas","California" "Total",111.1,7.1,7,8,12.1 "Do Not Have Cooling Equipment",17.8,1.8,"Q","Q",4.9 "Have Cooling Equipment",93.3,5.3,7,7.8,7.2 "Use Cooling Equipment",91.4,5.3,7,7.7,6.6 "Have Equipment But Do Not Use it",1.9,"Q","N","Q",0.6 "Air-Conditioning Equipment1, 2 " "Central System",65.9,1.1,6.4,6.4,5.4

104

"Table HC11.7 Air-Conditioning Usage Indicators by Northeast Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air-Conditioning Usage Indicators by Northeast Census Region, 2005" 7 Air-Conditioning Usage Indicators by Northeast Census Region, 2005" " Million U.S. Housing Units" ,,"Northeast Census Region" ,"U.S. Housing Units (millions)" ,,,"Census Division" ,,"Total Northeast" "Air Conditioning Usage Indicators",,,"Middle Atlantic","New England" "Total",111.1,20.6,15.1,5.5 "Do Not Have Cooling Equipment",17.8,4,2.4,1.7 "Have Cooling Equipment",93.3,16.5,12.8,3.8 "Use Cooling Equipment",91.4,16.3,12.6,3.7 "Have Equipment But Do Not Use it",1.9,0.3,"Q","Q" "Type of Air-Conditioning Equipment1, 2" "Central System",65.9,6,5.2,0.8 "Without a Heat Pump",53.5,5.5,4.8,0.7

105

"Table HC15.7 Air-Conditioning Usage Indicators by Four Most Populated States, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air-Conditioning Usage Indicators by Four Most Populated States, 2005" 7 Air-Conditioning Usage Indicators by Four Most Populated States, 2005" " Million U.S. Housing Units" ,"Housing Units (millions)","Four Most Populated States" "Air Conditioning Usage Indicators",,"New York","Florida","Texas","California" "Total",111.1,7.1,7,8,12.1 "Do Not Have Cooling Equipment",17.8,1.8,"Q","Q",4.9 "Have Cooling Equipment",93.3,5.3,7,7.8,7.2 "Use Cooling Equipment",91.4,5.3,7,7.7,6.6 "Have Equipment But Do Not Use it",1.9,"Q","N","Q",0.6 "Type of Air-Conditioning Equipment1, 2" "Central System",65.9,1.1,6.4,6.4,5.4

106

"Table HC10.7 Air-Conditioning Usage Indicators by U.S. Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air-Conditioning Usage Indicators by U.S. Census Region, 2005" 7 Air-Conditioning Usage Indicators by U.S. Census Region, 2005" " Million U.S. Housing Units" ,"Housing Units (millions)","U.S. Census Region" "Air Conditioning Usage Indicators",,"Northeast","Midwest","South","West" "Total",111.1,20.6,25.6,40.7,24.2 "Do Not Have Cooling Equipment",17.8,4,2.1,1.4,10.3 "Have Cooling Equipment",93.3,16.5,23.5,39.3,13.9 "Use Cooling Equipment",91.4,16.3,23.4,38.9,12.9 "Have Equipment But Do Not Use it",1.9,0.3,"Q",0.5,1 "Type of Air-Conditioning Equipment1, 2" "Central System",65.9,6,17.3,32.1,10.5 "Without a Heat Pump",53.5,5.5,16.2,23.2,8.7

107

"Table HC13.7 Air-Conditioning Usage Indicators by South Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air-Conditioning Usage Indicators by South Census Region, 2005" 7 Air-Conditioning Usage Indicators by South Census Region, 2005" " Million U.S. Housing Units" ,,"South Census Region" ,"U.S. Housing Units (millions)" ,,,"Census Division" ,,"Total South" "Air Conditioning Usage Indicators",,,"South Atlantic","East South Central","West South Central" "Total",111.1,40.7,21.7,6.9,12.1 "Do Not Have Cooling Equipment",17.8,1.4,0.8,0.2,0.3 "Have Cooling Equipment",93.3,39.3,20.9,6.7,11.8 "Use Cooling Equipment",91.4,38.9,20.7,6.6,11.7 "Have Equipment But Do Not Use it",1.9,0.5,"Q","Q","Q" "Type of Air-Conditioning Equipment1, 2"

108

The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration  

Open Energy Info (EERE)

The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration and Air Conditioning Jump to: navigation, search Tool Summary LAUNCH TOOL Name: The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration and Air Conditioning Agency/Company /Organization: World Resources Institute, World Business Council for Sustainable Development Sector: Energy, Climate Focus Area: Greenhouse Gas Phase: Determine Baseline, Evaluate Effectiveness and Revise as Needed Resource Type: Software/modeling tools User Interface: Spreadsheet Website: www.ghgprotocol.org/calculation-tools/all-tools Cost: Free References: Refrigerant Guide[1] The Greenhouse Gas Protocol tool for refrigeration is a free Excel spreadsheet calculator designed to calculate GHG emissions specifically

109

Heating, Ventilation, and Air Conditioning Renovations | Department of  

Broader source: Energy.gov (indexed) [DOE]

Heating, Ventilation, and Air Conditioning Renovations Heating, Ventilation, and Air Conditioning Renovations Heating, Ventilation, and Air Conditioning Renovations October 16, 2013 - 4:49pm Addthis Renewable Energy Options for HVAC Renovations Geothermal Heat Pumps (GHP) Solar Water Heating (SWH) Biomass Passive Solar Heating Biomass Heating Solar Ventilation Air Preheating Federal building renovations that encompass the heating, ventilation, and air conditioning (HVAC) systems in a facility provide a range of renewable energy opportunities. The primary technology option for HVAC renovations is geothermal heat pumps (GHP). Other options include leveraging a solar water heating (SWH) system to offset heating load or using passive solar heating or a biomass-capable furnace or boiler. Some facilities may also take

110

Reducing Air-Conditioning System Energy Using a PMV Index  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Maximize Comfort: Temperature, Humidity and IAQ Vol.I-4-1 Reducing Air-Conditioning System Energy Using a PMV Index Hui Li Qingfan Zhang Associate professor...

Li, H.; Zhang, Q.

2006-01-01T23:59:59.000Z

111

Dynamic Modeling and Cascaded Control for a Multi-Evaporator Supermarket Refrigeration System  

E-Print Network [OSTI]

The survey from US Department of Energy showed that about one-third of energy consumption in US is due to air conditioning and refrigeration systems. This significant usage of electricity in the HVAC industry has prompted researchers to develop...

Gupta, Ankush 1986-

2012-09-27T23:59:59.000Z

112

Advances in the development of energy efficient technologies: Sea Water Air Conditioning (SWAC)  

SciTech Connect (OSTI)

Sea water air conditioning (SWAC) is a cost effective and environmentally friendly alternative to and/or enhancement of air conditioning from mechanical chillers. SWAC pumps cold sea water from the appropriate ocean depths (50 to 3,000 feet depending on the climate and local characteristics) to the shore where it replaces (by direct cooling) or enhances (through use as condenser water) large mechanical chillers found in coastal facilities. SWAC direct cooling uses less than twenty per cent of the electricity of a mechanical chiller and uses no refrigerants whatsoever. Indirect cooling also offers substantial energy savings. Both systems dispense with the need for a cooling tower. Technical advances over the last twenty years in corrosion resistant alloys (titanium or aluminum), bio-fouling deterrence, and deep ocean pipeline deployment allow SWAC installations to use reliable, off-the-shelf technology. SWAC works in a variety of climates (existing installations are in Hawaii and Halifax, Nova Scotia), giving it significant domestic and international potential. Economy-of-scale advantages make it attractive to district cooling schemes.

Coony, J.E. [Boston Pacific Co., Inc., Washington, DC (United States)

1996-11-01T23:59:59.000Z

113

Development of cold seawater air conditioning systems for application as a demand side management tool for Hawaii and other subtropical climates  

SciTech Connect (OSTI)

Because of the proximity to deep cold seawater for many coastal regions in Hawaii and the high demand for air conditioning in large buildings, seawater air conditioning (SWAC) is a major potential sustainable energy resource for Hawaii and other subtropical regions of the world. The basic concept of seawater air conditioning is the use deep cold seawater to cool the chilled water in one or more air conditioned buildings as opposed to using energy intensive refrigeration systems. The economic viability of the seawater air conditioning is determined by comparing the construction and operating costs of the seawater supply system to the construction and operating costs of conventional air conditioning systems. The State of Hawaii commissioned an analysis to identify the technical and economic opportunities and limitations in the use of SWAC in Hawaii. The result of this work is a feasibility analysis of SWAC systems in the state and the potential associated energy savings. The study looked at the prospects of installing such a system at a major new resort development on Oahu called West Beach.

Kaya, M.H. [State of Hawaii, Honolulu, HI (United States). Dept. of Business, Economic Development, and Tourism

1996-10-01T23:59:59.000Z

114

Standards in acoustics of the American Society of Heating, Refrigeration, and Air?Conditioning Engineers (ASHRAE)  

Science Journals Connector (OSTI)

This paper presents the extent of ASHRAE’s involvement in sound and noise standards. ASHRAE has only a limited number of formal standards in acoustics but its two volumes of the four?volume set of handbooks contain many items that have become de facto standards. The ‘‘Fundamentals Handbook’’ and the ‘‘Applications Handbook’’ provide tables that show the power loss due to end reflection attenuation of lined ducts room criteria approaches and metrics and other material properties that are used even though and in spite of the fact that they never were evaluated as a standard by Canvass or other means. I will summarize the topics in the ASHRAE publications and discuss the limitations and current controversial topics.

2000-01-01T23:59:59.000Z

115

Uncertainty of sound power levels determined following Air Conditioning Heating and Refrigeration Institute Standard 220  

Science Journals Connector (OSTI)

As part of the AHRI ASA-ANSI and ISO standards development processes the uncertainty of sound power measurements needs to be quantified for inclusion in sound power standards. A study of four reverberation rooms with volumes of 140 280 560 and 1790 cubic meters was undertaken. Sound power levels for five noise sources (two vertical shafted sound sources two horizontal shafted sound sources and a leaf blower) were determined using ARI Standard 220. Variables investigated include: source location source orientation room conditions source operating characteristics and microphone traverse length. The frequency range of interest was 25 Hz to 10 kHz. Measurements were repeated and the order of tests was randomized. Of particular interest was the difference between the 140 cubic foot room and the other rooms to confirm the room qualification process required by ARI Standard 220 because the 140 cubic foot room does not meet the ARI Standard 220 qualification process but does meet the requirements in ISO 3741. This work will be helpful in understanding the sources of variation and allow for a starting point for determining if improvements are needed and if so what factors should be considered.

2010-01-01T23:59:59.000Z

116

3172, Page 1 International Refrigeration and Air Conditioning Conference at Purdue, July 16-19, 2012  

E-Print Network [OSTI]

insulation, thermal conductivity, heat transfer, moisture accumulation, chiller pipelines ABSTRACT Mechanical of pipe insulation systems had quite different water absorption rates due to different characteristics

Ghajar, Afshin J.

117

2416, Page 1 International Refrigeration and Air Conditioning Conference at Purdue, July 12-15, 2010  

E-Print Network [OSTI]

of their compactness and efficiency in residential and commercial applications. However, their usage as outdoor of the fins. 1. INTRODUCTION Heat pump systems are used for cooling and heating of buildings all year round, and fin surface energy on frost growth (Ohkubo, 2006; Shin et al., 2003). Measuring frost weight

118

Rotary Vapor Compression Cycle Technology: A Pathway to Ultra-Efficient Air Conditioning, Heating and Refrigeration  

Broader source: Energy.gov [DOE]

Lead Performer: Sandia National Laboratories, Livermore, CAPartners: Creative Thermal Solutions, Urbana, IL

119

Use of chlorofluorocarbons in refrigeration, insulation and mobile air conditioning in the USA*  

E-Print Network [OSTI]

that the atmospheric release of certain Halon 1211, Halon 1301, carbon tetrachloride and substances can result ozone were produced by the USA. These chemicals were chlorofluorocarbons (CFCs), halons, carbon tetrachloride and methyl chloroform. Roughly 40% ofthe total production of these ozone-depleting substances

Oak Ridge National Laboratory

120

Neural modeling of vapor compression refrigeration cycle with extreme learning machine  

Science Journals Connector (OSTI)

In this paper, a single-hidden layer feed-forward neural network (SLFN) is used to model the dynamics of the vapor compression cycle in refrigeration and air-conditioning systems, based on the extreme learning machine (ELM). It is shown that the assignment ... Keywords: Back propagation, Extreme learning machine, Modeling, Radial basis function, Support vector regression, Vapor compression refrigeration cycle

Lei Zhao; Wen-Jian Cai; Zhi-Hong Man

2014-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Refrigerator/freezer energy use: Measured values vs. simulation results  

SciTech Connect (OSTI)

The EPA Refrigerator Analysis (ERA) program was utilized in the engineering analysis performed to support the proposed refrigerator/freezer standards in the United States. In this paper the accuracy of the ERA program for predicting the energy consumption of domestic refrigerators, freezers, and refrigerator-freezers is studied by comparing the predicted energy consumption with the measured energy consumption.

Hakim, S.H.; Turiel, I. [Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.

1997-12-31T23:59:59.000Z

122

New Method Gives Precise Control in Air Conditioning  

Science Journals Connector (OSTI)

The Niagara "Controlled Humidity Method" is a new system of air conditioning giving complete control of temperature and relative humidity, holding constant conditions or varying them at the will of the user. ... A condition of 15 grains o f moisture per pound of air at 85 dcg. ...

1950-01-09T23:59:59.000Z

123

New Method Gives Precise Control in Air Conditioning  

Science Journals Connector (OSTI)

•The Niagara "Controlled Humidity Method" is a new system of air conditioning giving complete control of temperature and relative humidity, holding constant conditions or varying them at the will of the user. ... A condition of 15 grains of moisture per pound of air at 85 deg. ...

1950-02-13T23:59:59.000Z

124

A diffusion approximation approach to stochastic modeling of air conditioning type loads  

E-Print Network [OSTI]

that the air conditioning unit is on and off. In the followino equations, TNIN and TNAX are the lower and upper limit temperatures of the thermostat deadband and To is the outside temperature. Gi 2Gw To Tw Cw Ci $ QeXt To - outside temperature Tw - wall... temperature Ti - inside temperature Gw ? thermal conductance of wall Gi - thermal conductance of air Cw - thermal capacitance of wall Ci ? thermal capacitance of air Qe - rated capacity of cooling unit Xt - zero-one process describing the switching...

Roy, Teresa Henryka

1981-01-01T23:59:59.000Z

125

Downhole pulse tube refrigerators  

SciTech Connect (OSTI)

This report summarizes a preliminary design study to explore the plausibility of using pulse tube refrigeration to cool instruments in a hot down-hole environment. The original motivation was to maintain Dave Reagor`s high-temperature superconducting electronics at 75 K, but the study has evolved to include three target design criteria: cooling at 30 C in a 300 C environment, cooling at 75 K in a 50 C environment, cooling at both 75 K and 30 C in a 250 C environment. These specific temperatures were chosen arbitrarily, as representative of what is possible. The primary goals are low cost, reliability, and small package diameter. Pulse-tube refrigeration is a rapidly growing sub-field of cryogenic refrigeration. The pulse tube refrigerator has recently become the simplest, cheapest, most rugged and reliable low-power cryocooler. The authors expect this technology will be applicable downhole because of the ratio of hot to cold temperatures (in absolute units, such as Kelvin) of interest in deep drilling is comparable to the ratios routinely achieved with cryogenic pulse-tube refrigerators.

Swift, G.; Gardner, D. [Los Alamos National Lab., NM (United States). Condensed Matter and Thermal Physics Group

1997-12-01T23:59:59.000Z

126

Table HC9.6 Air Conditioning Characteristics by Climate Zone, 2005  

U.S. Energy Information Administration (EIA) Indexed Site

6 Air Conditioning Characteristics by Climate Zone, 2005 6 Air Conditioning Characteristics by Climate Zone, 2005 Million U.S. Housing Units Total......................................................................... 111.1 10.9 26.1 27.3 24.0 22.8 Do Not Have Cooling Equipment........................... 17.8 3.2 4.7 3.6 5.5 0.9 Have Cooling Equipment........................................ 93.3 7.7 21.4 23.7 18.5 21.9 Use Cooling Equipment......................................... 91.4 7.6 21.0 23.4 17.9 21.7 Have Equipment But Do Not Use it........................ 1.9 Q 0.4 0.4 0.6 0.3 Air-Conditioning Equipment 2, 3 Central System...................................................... 65.9 4.8 12.3 15.1 14.9 18.7 Without a Heat Pump......................................... 53.5 4.7 11.5 11.6 12.3 13.6 With a Heat Pump..............................................

127

Refrigerator-freezer energy testing with alternative refrigerants  

SciTech Connect (OSTI)

As a result of the Montreal Protocol that limits the production of ozone-depleting refrigerants, manufacturers are searching for alternatives to replace the R12 that is presently used in residential refrigerator-freezers. Before an alternative can be selected, several issues must be resolved. Among these are energy impacts, system compatibility, cost, and availability. In an effort to determine the energy impacts of some of the alternatives, energy consumption tests were performed in accordance with section 8 of the Association of Home Appliance Manufacturers (AHAM) standard for household refrigerators and household freezers. The results are presented for an 18 cubic foot (0.51 cubic meter), top-mount refrigerator-freezer with a static condenser using the following refrigerants: R12, R500, R12/Dimethyl-ether (DME), R22/R142b, and R134a. Conclusions from the AHAM test are that R500 and R12 /DME have a reduced energy consumption relative to R12 when replaced in the test unit with no modifications to the refrigeration system. Run times were slightly lower than R12 for both refrigerants indicating a higher capacity. While the R134a and R22/R142b results were less promising refrigeration system, such as a different capillary tube or compressor, may improve their performance. 12 refs., 2 figs., 3 tabs.

Vineyard, E.A.; Sand, J.R.; Miller, W.A.

1989-01-01T23:59:59.000Z

128

Solid-Vapor Sorption Refrigeration Systems  

E-Print Network [OSTI]

adsorbents in heat pump cycles: 1. A high usable refrigerant mass per unit mass of adsorbent. 2. A high energy of adsorption and desorption. 3. Heat flows and composition changes occur at constant temperature. The advantages of complex compounds... 2. Useable refrigerant densities. Summarizing, complex compound exhibit inherent characteristics which make them ideal adsorbents in heat pump cycles: 1. A high usable refrigerant mass per unit mass of adsorbent. 2. A high energy of adsorption...

Graebel, W.; Rockenfeller, U.; Kirol, L.

129

Study of thermoelectric technology for automobile air conditioning  

SciTech Connect (OSTI)

An analytical study was conducted to determine the feasibility of employing thermoelectric (TE) cooling technology in automobile air conditioners. The study addressed two key issues -- power requirements and availability of thermoelectric materials. In this paper, a mathematical model was developed to predict the performance of TE air conditioners and to analyze power consumption. Results show that the power required to deliver a cooling capacity of 4 kW (13,80 Btu/h) in a 38{degree}C (100{degree}F) environment will be 9.5 kW electric. Current TE modules suitable for air conditioning are made of bismuth telluride. The element tellurium is expected to be in short supply if TE cooling is widely implemented for auto air conditioning; some options available in this regard were studied and presented in this paper.

Mathiprakasam, B.; Heenan, P. (Midwest Research Inst., Kansas City, MO (United States)); Mei, V.C.; Chen, F.C. (Oak Ridge National Lab., TN (United States))

1991-01-01T23:59:59.000Z

130

Air-Conditioning Systems Simulate World-Wide Climates  

Science Journals Connector (OSTI)

Air-Conditioning Systems Simulate World-Wide Climates ... WEATHER conditions equivalent to those in any part of the world can be simulated in a four-compartment test box set up at State College, Penna., by the U. S. Department of Agriculture's Regional Pasture Research Laboratory in its work to develop better pastures. ... Three heavily insulated doors permit access to each compartment; an inner door keeps conditioned air in the box from rushing out when the main door is opened. ...

1941-10-25T23:59:59.000Z

131

Fetz Plumbing, Heating & Air Conditioning | Open Energy Information  

Open Energy Info (EERE)

Fetz Plumbing, Heating & Air Conditioning Fetz Plumbing, Heating & Air Conditioning Jump to: navigation, search Name Fetz Plumbing, Heating & Air Conditioning Address 115 Washington Street - P.O. Box 516 Place Urbana, Ohio Zip 43078 Sector Efficiency, Geothermal energy, Services, Solar Product Installation; Maintenance and repair Phone number 937-652-1136 Website http://fetzphc.com Coordinates 40.108862°, -83.757291° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.108862,"lon":-83.757291,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

132

Refrigerator recycling and CFCs  

SciTech Connect (OSTI)

Utility-sponsored refrigerator and freezer pick-up programs have removed almost 900,000 inefficient appliances from the North American electric grid to date. While the CFC-12 refrigerant from the discarded appliances is typically removed and recycled, in all but a few programs the CFC-11 in the foam insulation is not. About a quarter-billion pounds of CFC-11 are banked in refrigerator foam in the United States. Release of this ``bank`` of CFC, combined with that from foam insulation used in buildings, will be the largest source of future emissions if preventive measures are not taken. Methods exist to recover the CFC for reuse or to destroy it by incineration. The task of recycling or destroying the CFCs and other materials from millions of refrigerators is a daunting challenge, but one in which utilities can play a leadership role. E Source believes that utilities can profitably serve as the catalyst for public-private partnerships that deliver comprehensive refrigerator recycling. Rather than treating such efforts solely as a DSM resource acquisition, utilities could position these programs as a multifaceted service delivery that offers convenient appliance removal for homeowners, a solid waste minimization service for landfills, a source of recycled materials for industry, and a CFC recovery and/or disposal service in support of the HVAC industry and society`s atmospheric protection goals and laws. Financial mechanisms could be developed through these public-private enterprises to ensure that utilities are compensated for the extra cost of fully recycling refrigerators, including the foam CFC.

Shepard, M.; Hawthorne, W.; Wilson, A.

1994-12-31T23:59:59.000Z

133

Impact of Charge Degradation on the Life Cycle Climate Performance of a Residential Air-Conditioning System  

SciTech Connect (OSTI)

Vapor compression systems continuously leak a small fraction of their refrigerant charge to the environment, whether during operation or servicing. As a result of the slow leak rate occurring during operation, the refrigerant charge decreases until the system is serviced and recharged. This charge degradation, after a certain limit, begins to have a detrimental effect on system capacity, energy consumption, and coefficient of performance (COP). This paper presents a literature review and a summary of previous experimental work on the effect of undercharging or charge degradation of different vapor compression systems, especially those without a receiver. These systems include residential air conditioning and heat pump systems utilizing different components and refrigerants, and water chiller systems. Most of these studies show similar trends for the effect of charge degradation on system performance. However, it is found that although much experimental work exists on the effect of charge degradation on system performance, no correlation or comparison between charge degradation and system performance yet exists. Thus, based on the literature review, three different correlations that characterize the effect of charge on system capacity and energy consumption are developed for different systems as follows: one for air-conditioning systems, one for vapor compression water-to-water chiller systems, and one for heat pumps. These correlations can be implemented in vapor compression cycle simulation tools to obtain a better prediction of the system performance throughout its lifetime. In this paper, these correlations are implemented in an open source tool for life cycle climate performance (LCCP) based design of vapor compression systems. The LCCP of a residential air-source heat pump is evaluated using the tool and the effect of charge degradation on the results is studied. The heat pump is simulated using a validated component-based vapor compression system model and the LCCP results obtained using the three charge degradation correlations are compared.

Beshr, Mohamed [University of Maryland, College Park; Aute, Vikrant [University of Maryland, College Park; Abdelaziz, Omar [ORNL; Fricke, Brian A [ORNL; Radermacher, Reinhard [University of Maryland, College Park

2014-01-01T23:59:59.000Z

134

Intermittent absorption refrigeration system equipped with an economizer  

Science Journals Connector (OSTI)

Abstract Conservation of useful form of energy, i.e. electricity to be used in the production sector rather than consumption sector is becoming a priority in the KSA (Kingdom of Saudi Arabia). One of the consumption sectors which utilize a large amount of electrical energy is the air-conditioning and refrigeration sector. Improving the performance of refrigeration and air-conditioning systems and utilizing solar energy in powering such systems will contribute to significant conservation of electrical energy in the kingdom of Saudi-Arabia. Hence, the objective of the present study is to improve the performance of intermittent solar absorption refrigeration system. To achieve this objective, the design of a conventional intermittent system has been modified by introducing an economizer into the system. The analysis of the modified design system indicated an increase of 20% in the coefficient of performance of the system.

S.A.M. Said; M.A.I. El-Shaarawi; M.U. Siddiqui

2013-01-01T23:59:59.000Z

135

Solar sorption refrigeration in Africa  

Science Journals Connector (OSTI)

Abstract Solar sorption refrigeration technologies are regarded as a promising way to meet the growing refrigeration needs in Africa, for thermal comfort, foods and crops, vaccines and medicines conservation. Sorption technologies projects and studies have been reported in Africa since the late 1970s. This paper describes the most representative reported research activities and projects in various African climatic conditions. An emphasis is put on demonstrative plants involving absorption, adsorption or desiccant cooling applications. From this overview, it appears that a lot of achievements have been made, though applications are mainly focused on small-size cold boxes for foods and vaccines preservation; no direct building air conditioning based on adsorption or absorption has been reported. Mediterranean countries seems to offer the best weather conditions for solar sorption refrigeration applications and plenty of related activities could be identified in these countries. A more adequate design for each of other climatic zones in Africa may then be relevant. As anywhere, the high cost of these technologies remains the main the biggest brake to their diffusion in Africa.

Kokouvi Edem N’Tsoukpoe; Daniel Yamegueu; Justin Bassole

2014-01-01T23:59:59.000Z

136

Experimental evaluation of automotive air-conditioning using HFC-134a and HC-134a  

Science Journals Connector (OSTI)

An experimental study to evaluate the energy consumption of an automotive air conditioning is presented. In this study these refrigerants will be tested using the experimental rig which simulated the actual cars as a cabin complete with a cooling system component of the actual car that is as the blower evaporator condenser radiators electric motor which acts as a vehicle engine and then the electric motor will operate the compressor using a belt and pulley system as well as to the alternator will recharge the battery. The compressor working with the fluids HFC-134a and HC-134a and has been tested varying the speed in the range 1000 1500 2000 and 2500 rpm. The measurements taken during the one hour experimental periods at 2-minutes interval times for temperature setpoint of 20°C with internal heat loads 0 500 700 and 1000 W. The final results of this study show an overall better energy consumption of the HFC-134a compared with the HC-134a.

Azhar Abdul Aziz

2012-01-01T23:59:59.000Z

137

Weatherking Heating & Air conditioning | Open Energy Information  

Open Energy Info (EERE)

Page Page Edit with form History Facebook icon Twitter icon » Weatherking Heating & Air conditioning Jump to: navigation, search Name Weatherking Heating & Air conditioning Address 51 Meadow Lane Place Northfield, Ohio Zip 44067 Sector Buildings, Efficiency, Geothermal energy, Renewable Energy, Services Product Business and legal services; Energy audits/weatherization; Energy provider: power production;Energy provider: wholesale;Engineering/architectural/design;Installation;Investment/finances;Maintenance and repair; Retail product sales and distribution Phone number 330-908-0281 Website http://www.weatherking1.com Coordinates 41.3340869°, -81.530299° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.3340869,"lon":-81.530299,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

138

" Million Housing Units, Final"  

U.S. Energy Information Administration (EIA) Indexed Site

Air Conditioning in U.S. Homes, by Housing Unit Type, 2009" Air Conditioning in U.S. Homes, by Housing Unit Type, 2009" " Million Housing Units, Final" ,,"Housing Unit Type" ,,"Single-Family Units",,"Apartments in Buildings With" ,"Total U.S.1 (millions)" ,," Detached"," Attached"," 2 to 4 Units","5 or More Units","Mobile Homes" "Air Conditioning" "Total Homes",113.6,71.8,6.7,9,19.1,6.9 "Air Conditioning Equipment" "Use Air Conditioning Equipment",94,61.1,5.6,6.3,15.2,5.8 "Have Air Conditioning Equipment But" "Do Not Use It",4.9,2.6,0.2,0.7,0.9,0.4 "Do Not Have Air Conditioning Equipment",14.7,8.1,0.9,2.1,3,0.7 "Type of Air Conditioning Equipment "

139

Influence of air conditioning management on heat island in Paris air street temperatures  

E-Print Network [OSTI]

Influence of air conditioning management on heat island in Paris air street temperatures Brice 2012 Available online 13 March 2012 Keywords: Air conditioning Heat island mitigation Urban heat island killer'', is exacerbated in urban areas owing to the heat island effect. Air conditioning (A/C) is a key

Ribes, Aurélien

140

Investigation of residential central air conditioning load shapes in NEMS  

SciTech Connect (OSTI)

This memo explains what Berkeley Lab has learned about how the residential central air-conditioning (CAC) end use is represented in the National Energy Modeling System (NEMS). NEMS is an energy model maintained by the Energy Information Administration (EIA) that is routinely used in analysis of energy efficiency standards for residential appliances. As part of analyzing utility and environmental impacts related to the federal rulemaking for residential CAC, lower-than-expected peak utility results prompted Berkeley Lab to investigate the input load shapes that characterize the peaky CAC end use and the submodule that treats load demand response. Investigations enabled a through understanding of the methodology by which hourly load profiles are input to the model and how the model is structured to respond to peak demand. Notably, it was discovered that NEMS was using an October-peaking load shape to represent residential space cooling, which suppressed peak effects to levels lower than expected. An apparent scaling down of the annual load within the load-demand submodule was found, another significant suppressor of the peak impacts. EIA promptly responded to Berkeley Lab's discoveries by updating numerous load shapes for the AEO2002 version of NEMS; EIA is still studying the scaling issue. As a result of this work, it was concluded that Berkeley Lab's customary end-use decrement approach was the most defensible way for Berkeley Lab to perform the recent CAC utility impact analysis. This approach was applied in conjunction with the updated AEO2002 load shapes to perform last year's published rulemaking analysis. Berkeley Lab experimented with several alternative approaches, including modifying the CAC efficiency level, but determined that these did not sufficiently improve the robustness of the method or results to warrant their implementation. Work in this area will continue in preparation for upcoming rulemakings for the other peak coincident end uses, commercial air conditioning and distribution transformers.

Hamachi LaCommare, Kristina; Marnay, Chris; Gumerman, Etan; Chan, Peter; Rosenquist, Greg; Osborn, Julie

2002-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Refrigerant directly cooled capacitors  

DOE Patents [OSTI]

The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.

Hsu, John S. (Oak Ridge, TN); Seiber, Larry E. (Oak Ridge, TN); Marlino, Laura D. (Oak Ridge, TN); Ayers, Curtis W. (Kingston, TN)

2007-09-11T23:59:59.000Z

142

Refrigerator-freezer energy testing with alternative refrigerants  

SciTech Connect (OSTI)

As a result of the Montreal Protocol (UNEP 1987) that limits the production of ozone-depleting refrigerants, manufacturers are searching for alternatives to replace the R12 that is presently used in residential refrigerator-freezers. Before an alternative can be selected, several issues must resolved. Among these are energy impacts, system compatibility, cost, and availability, In an effort to determine the energy impacts of some of the alternatives, energy consumption tests were performed in accordance with section 8 of the Association of Home Appliance Manufacturers (AHAM) standard for household refrigerators and household freezers (AHAM 1985). The results are presented for an 18 ft{sup 3} (0.51 m{sup 3}), top mount refrigerators-freezer with a static condenser using the following refrigerants: R 12, R500, R12/dimethylether (DME), R22/R142b, and R134a. Conclusions from the AHAM test are that R500 and R12/DME have a reduced energy consumption relative to R12 when replaced in the test unit with no modifications to the refrigeration system. Run times were slightly lower than R12 for both refrigerants, indicating a higher capacity. While the R134a and R22/R142b results were less promising (6.8% and 8.5% higher energy consumption, respectively), changes to the refrigeration system, such as a different capillary tube or compressor, may improve their performance. It is noted that the test results are only an initial step in determining a replacement for R12.

Sand, J.R. (Oak Ridge National Lab., Oak Ridge, TN (US)); Vineyard, E.A.; Sand, J.R.

1989-01-01T23:59:59.000Z

143

Enhanced Operation Strategies for Air-Conditioning and Lighting Systems Toward Peak Power Reduction for an Office Building in Kuwait  

E-Print Network [OSTI]

Enhanced?Operation?Strategies?for?Air? Conditioning?and?Lighting? Systems?Toward?Peak?Power?Reduction? for?an?Office?Building?in?Kuwait F. Alghimlas A. Al-Mulla G.P. Maheshwari D. Al-Nakib Building and Energy Technologies Department... Environment and Urban Development Division ICEBO 2012 Manchester, United Kingdom October 23-26, 2012 Electricity?Use?by?Sector?in?Kuwait Percentages?of?Primary?Energy?Utilization Percentages?of?Electricity?Utilization Yearly?Increase?in...

Alghimlas, F.; Al-Mulla, A.; Maheshwari, G.P.; Al-Nakib, D.

2012-01-01T23:59:59.000Z

144

Japanese and American competition in the development of scroll compressors and its impact on the American air conditioning industry  

SciTech Connect (OSTI)

This report examines the technological development of scroll compressors and its impact on the air conditioning equipment industry. Scroll compressors, although considered to be the compressors of the future for energy-efficient residential heat pumps and possibly for many other applications, are difficult to manufacture on a volume-production base. The manufacturing process requires computer-aided, numerically controlled tools for high-precision fabrication of major parts. Japan implemented a global strategy for dominating the technological world market in the 1970s, and scroll compressor technology benefited from the advent of new-generation machine tools. As a result, if American manufacturers of scroll compressors purchase or are essentially forced to purchase numerically controlled tools from Japan in the future, they will then become dependent on their own competitors because the same Japanese conglomerates that make numerically controlled tools also make scroll compressors. This study illustrates the importance of the basic machine tool industry to the health of the US economy. Without a strong machine tool industry, it is difficult for American manufacturers to put innovations, whether patented or not, into production. As we experience transformation in the air conditioning and refrigeration market, it will be critical to establish a consistent national policy to provide healthy competition among producers, to promote innovation within the industry, to enhance assimilation of new technology, and to eliminate practices that are incompatible with these goals. 72 refs., 8 figs., 1 tab.

Ushimaru, Kenji (Energy International, Inc., Bellevue, WA (USA))

1990-02-01T23:59:59.000Z

145

Form Date 4/4/01 Refrigerant Service Order Form  

E-Print Network [OSTI]

Recovery Unit ID # : Added Lbs oz Lbs oz Lbs oz Startup Charge Net Refrigerant Added: Lbs oz Parts UsedForm Date 4/4/01 Refrigerant Service Order Form Service ID: Owner: Work Order #: Building: Date: Issued: Completed: Equipment ID: Technicians: Location: Model: Manufact: Serial #: Refrigerant Type

Russell, Lynn

146

Fast Nonconvex Model Predictive Control for Commercial Refrigeration  

E-Print Network [OSTI]

its capabil- ity to minimize the total cost of energy for a commercial refrigeration system while multi-zone refrigeration system, consisting of several cooling units that share a common compressor. This corresponds roughly to 2% of the entire electricity consumption in the country. Refrigerated goods constitute

147

E-Print Network 3.0 - air-conditioned domestic buildings Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

water chillers will contain more than 3 kg. If information... , air conditioning and heat pump technology. However, certain fire protection equipment that contains F......

148

Impact of Vehicle Air-Conditioning on Fuel Economy, Tailpipe Emissions, and Electric Vehicle Range: Preprint  

SciTech Connect (OSTI)

Vehicle air-conditioning can significantly impact fuel economy and tailpipe emissions of conventional and hybrid electric vehicles and reduce electric vehicle range. In addition, a new US emissions procedure, called the Supplemental Federal Test Procedure, has provided the motivation for reducing the size of vehicle air-conditioning systems in the US. The SFTP will measure tailpipe emissions with the air-conditioning system operating. Current air-conditioning systems can reduce the fuel economy of high fuel-economy vehicles by about 50% and reduce the fuel economy of today's mid-sized vehicles by more than 20% while increasing NOx by nearly 80% and CO by 70%.

Farrington, R.; Rugh, J.

2000-09-22T23:59:59.000Z

149

Superinsulation in refrigerators and freezers  

SciTech Connect (OSTI)

The results presented here were obtained during Phase 4 of the first CRADA, which had the specific objective of determining the lifetime of superinsulations when installed in simulated refrigerator doors. The second CRADA was established to evaluate and test design concepts proposed to significantly reduce energy consumption in a refrigerator-freezer that is representative of approximately 60% of the US market. The stated goal of this CRADA is to demonstrate advanced technologies which reduce, by 50%, the 1993 National Appliance Energy Conservation Act (NAECA) standard energy consumption for a 20 ft{sup 3} (570 L) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translates to an energy consumption of 1.003 kWh/d. The general objective of the research is to facilitate the introduction of efficient appliances by demonstrating design changes that can be effectively incorporated into new products. In previous work on this project, a Phase 1 prototype refrigerator-freezer achieved an energy consumption of 1.413 kWh/d [Vineyard, et al., 1995]. Following discussions with an advisory group comprised of all the major refrigerator-freezer manufacturers, several options were considered for the Phase 2 effort, one of which was cabinet heat load reductions.

Vineyard, E.; Stovall, T.K.; Wilkes, K.E.; Childs, K.W.

1998-02-01T23:59:59.000Z

150

Compatibility of lubricant additives with HFC refrigerants and synthetic lubricants. Final report, Part 1  

SciTech Connect (OSTI)

Part one of this research provides manufacturers of components of air-conditioning and refrigeration equipment with a useful list of lubricant additives, sources, functional properties and chemical species. The list in part one is comprised of domestic lubricant additive suppliers and the results of a literature search that was specifically targeted for additives reported to be useful in polyolester chemistry.

Cavestri, R.C. [Imagination Resources, Inc., Dublin, OH (United States)

1997-07-01T23:59:59.000Z

151

2014-04-28 Issuance: Certification of Commercial HVAC, Water Heating, and Refrigeration Equipment; Final Rule  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule regarding the certification of commercial heating, ventilation, and air-conditioning (HVAC), water heating (WH), and refrigeration (CRE) equipment, as issued by the Deputy Assistant Secretary for Energy Efficiency on April 28, 2014.

152

An Evaluation of the Environmental Impact of Different Commercial Supermarket Refrigeration Systems Using Low Global Warming Potential Refrigerants  

SciTech Connect (OSTI)

Commercial refrigeration systems consumed 1.21 Quads of primary energy in 2010 and are known to be a major source for refrigerant charge leakage into the environment. Thus, it is important to study the environmental impact of commercial supermarket refrigeration systems and improve their design to minimize any adverse impacts. The system s Life Cycle Climate Performance (LCCP) was presented as a comprehensive metric with the aim of calculating the equivalent mass of carbon dioxide released into the atmosphere throughout its lifetime, from construction to operation and destruction. In this paper, an open source tool for the evaluation of the LCCP of different air-conditioning and refrigeration systems is presented and used to compare the environmental impact of a typical multiplex direct expansion (DX) supermarket refrigeration systems based on three different refrigerants as follows: two hydrofluorocarbon (HFC) refrigerants (R-404A, and R-407F), and a low global warming potential (GWP) refrigerant (N-40). The comparison is performed in 8 US cities representing different climates. The hourly energy consumption of the refrigeration system, required for the calculation of the indirect emissions, is calculated using a widely used building energy modeling tool (EnergyPlus). A sensitivity analysis is performed to determine the impact of system charge and power plant emission factor on the LCCP results. Finally, we performed an uncertainty analysis to determine the uncertainty in total emissions for both R-404A and N-40 operated systems. We found that using low GWP refrigerants causes a considerable drop in the impact of uncertainty in the inputs related to direct emissions on the uncertainty of the total emissions of the system.

Beshr, Mohamed [University of Maryland, College Park; Aute, Vikrant [University of Maryland, College Park; Abdelaziz, Omar [ORNL; Fricke, Brian A [ORNL; Radermacher, Reinhard [University of Maryland, College Park

2014-01-01T23:59:59.000Z

153

Investigating the Performance of Solar Air Conditioning Motivation/Background Findings  

E-Print Network [OSTI]

Investigating the Performance of Solar Air Conditioning Motivation/Background Findings Two Building-thermal collectors We investigated 3 types of solar cooling technologies: · Air conditioning consumes 10% of all conditioning can reduce energy consumption, only if paired with a suitable system · Conventional office air

154

Operation of Energy-Efficient Air-Conditioned Buildings: An Overview  

E-Print Network [OSTI]

To design an optimum HVAC airside system that provides comfort and air quality in the air-conditioned spaces with efficient energy consumption is a great challenge. This paper evaluates recent progresses of HVAC airside design for the air-conditioned...

Khalil, E. E.

2010-01-01T23:59:59.000Z

155

Experimental Investigation on the Operation Performance of a Liquid Desiccant Air-conditioning System  

E-Print Network [OSTI]

A large share of energy consumption is taken by an air-conditioning system. It worsens the electricity load of the power network. Therefore, more and more scholars are paying attention to research on new types of air-conditioning systems...

Liu, J.; Wang, J.; Wu, Z.; Gu, W.; Zhang, G.

2006-01-01T23:59:59.000Z

156

An overview of solar assisted air-conditioning system application in small office buildings in Malaysia  

Science Journals Connector (OSTI)

In many regions of the world especially tropical weather in Malaysia, the demand for cooling of indoor air is growing due to increasing comfort expectations and increasing cooling loads. Air-conditioning, the most common cooling mechanism for providing ... Keywords: Malaysian climatic conditions, absorption chiller, evacuated tube solar collector, high energy consumption, peak load demand, solar assisted air conditioning system, solar energy

Lim Chin Haw; Kamaruzzaman Sopian; Yusof Sulaiman

2009-02-01T23:59:59.000Z

157

" Million Housing Units, Final"  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air Conditioning in U.S. Homes, by Census Region, 2009" 7 Air Conditioning in U.S. Homes, by Census Region, 2009" " Million Housing Units, Final" ,,"Census Region" ,"Total U.S.1 (millions)" ,,"Northeast","Midwest","South","West" "Air Conditioning" "Total Homes",113.6,20.8,25.9,42.1,24.8 "Air Conditioning Equipment" "Use Air Conditioning Equipment",94,16.5,22.4,40.5,14.6 "Have Air Conditioning Equipment But" "Do Not Use It",4.9,1.4,1.2,0.9,1.4 "Do Not Have Air Conditioning Equipment",14.7,2.8,2.3,0.7,8.9 "Type of Air Conditioning Equipment " "Used (more than one may apply)" "Use Central Air Conditioning Equipment",69.7,7.2,17.1,34.6,10.8

158

The investigation of exhaust powered, automotive air cycle air conditioning  

E-Print Network [OSTI]

Pressure Ratio Net Power Test Apparatus Available Turbocompressors Turbine and Compressor Wheels Mounted to Shaft Turbocompressor Mounted. to Exhaust Line Total System Test Rig Full Throttle Performance Curves Subscript 'c' Corrected Results 13 13... an automotive air cycle unit which employed a rotary- vaned compressor. The prototype unit developed. cooling over various engine speeds because of the compressor being a positive displacement type which developed fairly high pressures on the order of 40 psia...

Holley, James Andrew

1978-01-01T23:59:59.000Z

159

Refrigerants in Transition  

E-Print Network [OSTI]

component of ternary blends and as a blowing agent. Further testing is ongoing to determine its performance characteristics. Since CFC-114 chillers constitute an estimated 1% of the more than 80,000 centrifugal chillers, testing has not been a high..., commercial refrigerators, ice makers, etc. Some commercial chillers. Some commercial refrigeration. Marine refrigeration, stationery chillers, ternary blends, blowing agents. 51 RESULTS OF TESTING The testing programs undertaken by the refrigerant...

Stouppe, D. E.

160

Energy performance of direct expansion air handling unit in office buildings  

Science Journals Connector (OSTI)

Abstract Buildings and their occupants generate a large amount of carbon emissions. In Korea, buildings contribute to about 30% of the total greenhouse gases emissions, and the proportion has been rapidly increasing to the level of the developed counties (i.e., more than 40% of the total emissions. A direct expansion air handling unit, of which a refrigerant is directly delivered to the heating and cooling, has a potential to save cooling and heating energy use, compared to water-based central air conditioning systems. The aim of this study is to compare heating and cooling energy uses of an identical office building but with different air conditioning systems, i.e. direct expansion and water-based air conditioning systems. Dynamic building energy simulations that reflect the actual use of a monitored building and its air handling unit operation have been conducted in this study. Simulation results show good agreement with the actual energy consumption obtained from the field measurements of the building. Our study quantifies the amount of cooling and heating energy uses saved by a direct expansion air handing unit and reveals reasons for this savings, i.e. higher energy efficiency of the unit and reduction in pump and fan energy demands.

Geun Young Yun; Jongdae Choi; Jeong Tai Kim

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Uninterrupted power supply for autonomous small refrigerators  

Science Journals Connector (OSTI)

The objective of this paper is to describe salient features of a small refrigerator powered by a field of photovoltaic panels backed up by a petrol-start, kerosene-run portable generator set. Such units find applications in medical shops, veterinary applications and storage of vaccines in primary health centers. The modular arrangement allows use of certain components as a part of an uninterrupted power supply system for such refrigerators. Some preliminary results on temperature distributions and performance data are also presented.

Thomachan A. Kattakayam; K. Srinivasan

1998-01-01T23:59:59.000Z

162

Solutions for Summer Electric Power Shortages: Demand Response and its Applications in Air Conditioning and Refrigerating Systems  

E-Print Network [OSTI]

for DR and demand side management, along with operationalresponse), DSM (demand side management), DR strategy, air

Han, Junqiao; Piette, Mary Ann

2008-01-01T23:59:59.000Z

163

Development of Optimization Tool for Air Conditioning System Operation  

E-Print Network [OSTI]

Operations, Berlin, Germany, October 20-22, 2008 Outside air temperature and the absolute air humidity are predicted by the Auto-regressive Integrated Moving Average (ARIMA) model [1],[2]. The solar radiation on a horizontal surface... of the error margin Energy Consumption (set value A) Energy Consumption (set value B) ESL-IC-08-10-55 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 J VAV unit is also operated under...

Sumiyoshi, D.; Akashi, Y.

164

Determination of properties of PVE lubricants with HFC refrigerants[PolyVinylEther  

SciTech Connect (OSTI)

Polyalkyleneglycol (PAG) and polyol ester (POE) have been developed as refrigeration lubricants, used with HFC134a. PAG is used for automotive air conditioning systems and POE is used for domestic reciprocating refrigerators and for A/C systems. Although PAG exhibits good lubricity performance, it is difficult to use for domestic reciprocating refrigerators due to its low dielectric property. POE is difficult to use for automotive A/C systems, due to hydrolysis and poor lubricity performance. Polyvinylether (PVE) can be used in place of PAG and POE with HFC refrigerants. PVE is used for A/C systems as well as refrigerator and freezer applications. PVE is an ideal lubricant for use with HFCs.

Kaneko, Masato; Sakanoue, Shuichi; Tazaki, Toshihiro; Tominaga, Shoichi; Takagi, Minoru; Goodin, M.

1999-07-01T23:59:59.000Z

165

Active magnetic refrigerants based on Gd-Si-Ge material and refrigeration apparatus and process  

DOE Patents [OSTI]

Active magnetic regenerator and method using Gd.sub.5 (Si.sub.x Ge.sub.1-x).sub.4, where x is equal to or less than 0.5, as a magnetic refrigerant that exhibits a reversible ferromagnetic/antiferromagnetic or ferromagnetic-II/ferromagnetic-I first order phase transition and extraordinary magneto-thermal properties, such as a giant magnetocaloric effect, that renders the refrigerant more efficient and useful than existing magnetic refrigerants for commercialization of magnetic regenerators. The reversible first order phase transition is tunable from approximately 30 K to approximately 290 K (near room temperature) and above by compositional adjustments. The active magnetic regenerator and method can function for refrigerating, air conditioning, and liquefying low temperature cryogens with significantly improved efficiency and operating temperature range from approximately 10 K to 300 K and above. Also an active magnetic regenerator and method using Gd.sub.5 (Si.sub.x Ge.sub.1-x).sub.4, where x is equal to or greater than 0.5, as a magnetic heater/refrigerant that exhibits a reversible ferromagnetic/paramagnetic second order phase transition with large magneto-thermal properties, such as a large magnetocaloric effect that permits the commercialization of a magnetic heat pump and/or refrigerant. This second order phase transition is tunable from approximately 280 K (near room temperature) to approximately 350 K by composition adjustments. The active magnetic regenerator and method can function for low level heating for climate control for buildings, homes and automobile, and chemical processing.

Gschneidner, Jr., Karl A. (Ames, IA); Pecharsky, Vitalij K. (Ames, IA)

1998-04-28T23:59:59.000Z

166

Active magnetic refrigerants based on Gd-Si-Ge material and refrigeration apparatus and process  

DOE Patents [OSTI]

Active magnetic regenerator and method using Gd{sub 5} (Si{sub x}Ge{sub 1{minus}x}){sub 4}, where x is equal to or less than 0.5, as a magnetic refrigerant that exhibits a reversible ferromagnetic/antiferromagnetic or ferromagnetic-II/ferromagnetic-I first order phase transition and extraordinary magneto-thermal properties, such as a giant magnetocaloric effect, that renders the refrigerant more efficient and useful than existing magnetic refrigerants for commercialization of magnetic regenerators. The reversible first order phase transition is tunable from approximately 30 K to approximately 290 K (near room temperature) and above by compositional adjustments. The active magnetic regenerator and method can function for refrigerating, air conditioning, and liquefying low temperature cryogens with significantly improved efficiency and operating temperature range from approximately 10 K to 300 K and above. Also an active magnetic regenerator and method using Gd{sub 5} (Si{sub x} Ge{sub 1{minus}x}){sub 4}, where x is equal to or greater than 0.5, as a magnetic heater/refrigerant that exhibits a reversible ferromagnetic/paramagnetic second order phase transition with large magneto-thermal properties, such as a large magnetocaloric effect that permits the commercialization of a magnetic heat pump and/or refrigerant. This second order phase transition is tunable from approximately 280 K (near room temperature) to approximately 350 K by composition adjustments. The active magnetic regenerator and method can function for low level heating for climate control for buildings, homes and automobile, and chemical processing. 27 figs.

Gschneidner, K.A. Jr.; Pecharsky, V.K.

1998-04-28T23:59:59.000Z

167

Cool energy savings opportunities in commercial refrigeration  

SciTech Connect (OSTI)

The commercial sector consumes over 13 quads of primary energy annually. Most of this consumption (two-thirds) meets the energy needs of lighting and heating, ventilation, and air-conditioning. The largest consuming group of the remaining one-third is commercial refrigeration at about one quad annually (990 trillion Btu), valued at over $7 billion per year to the commercial sector consumer. Potential energy savings are estimated to be about 266 trillion Btu, with consumer savings valued at about $2 billion. This study provides the first known estimates of these values using a bottom-up approach. The authors evaluated numerous self-contained and engineered commercial refrigeration systems in this study, such as: supermarket central systems, beverage merchandisers, ice machines, and vending machines. Typical physical characteristics of each equipment type were identified at the component level for energy consumption. This information was used to form a detailed database from which they arrived at the estimate of 990 trillion Btu energy consumption for the major equipment types used in commercial refrigeration. Based on the implementation of the most cost-effective technology improvements for the seven major equipment types, they estimated an annual potential energy savings of 266 trillion Btu. Much of the savings can be realized with the implementation of high-efficiency fan motors and compressors. In many cases, payback can be realized within three years.

Westphalen, D.; Brodrick, J.; Zogg, R.

1998-07-01T23:59:59.000Z

168

Estimated United States Residential Energy Use in 2005  

SciTech Connect (OSTI)

A flow chart depicting energy flow in the residential sector of the United States economy in 2005 has been constructed from publicly available data and estimates of national energy use patterns. Approximately 11,000 trillion British Thermal Units (trBTUs) of electricity and fuels were used throughout the United States residential sector in lighting, electronics, air conditioning, space heating, water heating, washing appliances, cooking appliances, refrigerators, and other appliances. The residential sector is powered mainly by electricity and natural gas. Other fuels used include petroleum products (fuel oil, liquefied petroleum gas and kerosene), biomass (wood), and on-premises solar, wind, and geothermal energy. The flow patterns represent a comprehensive systems view of energy used within the residential sector.

Smith, C A; Johnson, D M; Simon, A J; Belles, R D

2011-12-12T23:59:59.000Z

169

Leducq, Roche, Macchi-Tejeda , Fournaison, Guilpart Workshop on Refrigerant Charge Reduction, Cemagref Antony, France, 2009 1  

E-Print Network [OSTI]

Leducq, Roche, Macchi-Tejeda , Fournaison, Guilpart IIR 1st Workshop on Refrigerant Charge, Antony cedex, 92 163,, France denis.leducq@cemagref.fr ABSTRACT A design of a low charge refrigerating on refrigerant charge and energy performance has been evaluated experimentally for a cold room refrigerating unit

Paris-Sud XI, Université de

170

Analysis of the Diagnostic Methods of the Performance Failure of Heating and Air Conditioning Systems  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Co ntrol Systems for Energy Efficiency and Comfort, Vol. V-5-2 Analysis of the Diagnostic Methods of the Performance Failure of Heating and Air Conditioning Systems Lianyou LI Zhihong ZHANG Yong...

Li, L.; Zhang, Z.; Sun, Y.; Li, D.; Xie, H.

2006-01-01T23:59:59.000Z

171

Economic Analysis and Comparison of Waste Water Resource Heat Pump Heating and Air-Conditioning System  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Renewable Energy Resources and a Greener Future, Vol.VIII-8-1 Economic Analysis and Comparison of Waste Water Resource Heat Pump Heating and Air-conditioning System Chunlei Zhang Suilin Wang Hongbing Chen...

Zhang, C.; Wang, S.; Chen, H.; Shi, Y.

2006-01-01T23:59:59.000Z

172

Analysis of Air Conditioning Effectiveness vs. Outdoor Conditions: Traditional Bins or Joint Frequency Bins?  

E-Print Network [OSTI]

There are a number of methods used to estimate the effectiveness of air conditioning equipment in handling loads. Full hourly computer simulations are probably the most accurate, but lack flexibility and are more cumbersome to use than more compact...

Cohen, B. M.

1998-01-01T23:59:59.000Z

173

Multi-Domain Modeling and Simulation of Automotive Air Conditioning System Based On Modelica  

Science Journals Connector (OSTI)

The automotive air conditioning (AC) systems are complex systems where two-phase flow, pneumatic, mechanical and electrical components are coupled. Such systems coupled with various physical domains have great...

Jing Li; Yunqing Zhang…

2013-01-01T23:59:59.000Z

174

Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems  

E-Print Network [OSTI]

Austria, September 2006. Modelica As- sociation and Arsenalsystems. The ?exibility of Modelica has been T room in [° C]lss. AirConditioning - a Modelica li- o brary for dynamic

Wetter, Michael

2010-01-01T23:59:59.000Z

175

Demand response: a strategy to address residential air-conditioning peak load in Australia  

Science Journals Connector (OSTI)

Rapid growth in electricity network peak demand is increasing pressure for new investment which may be used for only a few hours a year. Residential air-conditioning is widely believed to be the prime cause of...

Robert Smith; Ke Meng; Zhaoyang Dong…

2013-12-01T23:59:59.000Z

176

Flywheel Cooling: A Cooling Solution for Non Air-Conditioned Buildings  

E-Print Network [OSTI]

"Flywheel Cooling" utillzes the natural cooling processes of evaporation, ventilation and air circulation. These systems are providing low-cost cooling for distribution centers, warehouses, and other non air-conditioned industrial assembly plants...

Abernethy, D.

177

Research on Solar High-Temperature Absorption Air-Conditioning Systems  

Science Journals Connector (OSTI)

This paper studies the characteristics and performance of solar higher-temperature absorption air conditioning systems which employed linear concentrating collectors and double-effect absorption chillers. A solar...

Guoqing Yu; Jinhua Tang; Zhijun Zou

2009-01-01T23:59:59.000Z

178

Improving the Performance of Air-Conditioning Systems in an ASEAN Climate  

E-Print Network [OSTI]

This paper describes an analysis of air conditioning performance under hot and humid tropical climate conditions appropriate to the Association of South East Asian Nations (ASEAN) countries. This region, with over 280 million people, has one...

Busch, J. F.; Warren, M. L.

1988-01-01T23:59:59.000Z

179

E-Print Network 3.0 - automative air-conditioning systems Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

systems Page: << < 1 2 3 4 5 > >> 1 PLEASE HELP SAVE ENERGY Learn how to control the heating system for your room. Summary: & SW Heat & air conditioning control Cary E & NE &...

180

Feasibility of Municipal Water Mains as Heat Sink for Residential Air-Conditioning  

E-Print Network [OSTI]

It has been proposed that municipal water mains be used as the heat sink or the heat source for air-conditioning or heating, respectively. This paper addresses the extent of thermal contamination associated with the use of municipal water...

Vliet, G. C.

1994-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Development and modelling of a solar assisted liquid desiccant dehumidification air-conditioning system  

Science Journals Connector (OSTI)

This paper presents the development and simulation of an advanced solar assisted liquid desiccant dehumidification air-conditioning system for ... regenerator, and an array of flat plate solar collectors. The sys...

Aqeel Kareem Mohaisen; Zhenjun Ma

2014-09-01T23:59:59.000Z

182

Energy Comparison Between Conventional and Chilled Water Thermal Storage Air Conditioning Systems  

E-Print Network [OSTI]

, encouraged by government subsidies and driven by the rapid and continual expansion in building construction, urban development, and the heavy reliance on Air Conditioning (AC) systems for the cooling of buildings. The Chilled Water Thermal Storage (CWTS...

Sebzali, M.; Hussain, H. J.; Ameer, B.

2010-01-01T23:59:59.000Z

183

Direct-Expansion Air-Conditioning System Performance in Low Humidity Applications: A Case Study  

E-Print Network [OSTI]

DIRECT-EXPANSION AIR-CONDITIONING SYSTEM PERFORMANCE IN LOW HUMIDITY APPLICATIONS: A CASE STUDY MUKESH K. KHATTAR, P.E. DENNIS KEEBAUGH, P.E. Senior Systems Engineer Senior Research Engineer Florida Solar Energy Center Shenandoah Solar Center... warehouse. The flat gravel roof is exposed to sun. The 16' ceiling is insulated with two inch spray foam. Entrance to the warehouse is through sealed and insulated doors located on the west partition wall. The air -conditioning sys tem on this leased...

Khattar, M. K.; Keebaugh, D.

1987-01-01T23:59:59.000Z

184

Discussion of Air-Conditioning Energy-Savings in Hot-Summer and Cold-Winter Regions  

E-Print Network [OSTI]

Introducing several kinds of air-conditioning systems energy conservation measures, and according to the climate of the hot-summer and cold-winter region in China, this paper puts forward an overall conception for air-conditioning energy...

Zheng, W.; Gong, F.; Lou, X.; Cheng, J.

2006-01-01T23:59:59.000Z

185

The Coordinated Control of a Central Air Conditioning System Based on Variable Chilled Water Temperature and Variable Chilled Water Flow  

E-Print Network [OSTI]

At present, regulation of water flow by means of pump frequency conversion is one of the major methods for power-saving in central air conditioning systems. In this article, optimization regulation for central air conditioning system on the basis...

Liu, J.; Mai, Y.; Liu, X.

2006-01-01T23:59:59.000Z

186

" Million Housing Units, Final"  

U.S. Energy Information Administration (EIA) Indexed Site

2 Air Conditioning in U.S. Homes, by Owner/Renter Status, 2009" 2 Air Conditioning in U.S. Homes, by Owner/Renter Status, 2009" " Million Housing Units, Final" ,,,,"Housing Unit Type" ,,,,"Single-Family Units",,,,"Apartments in Buildings With" ,,,,"Detached",,"Attached",,"2 to 4 Units",,"5 or More Units",,"Mobile Homes" ,"Total U.S.1 (millions)" "Air Conditioning",,"Own","Rent","Own","Rent","Own","Rent","Own","Rent","Own","Rent","Own","Rent" "Total Homes",113.6,76.5,37.1,63.2,8.6,3.9,2.8,1.5,7.6,2.3,16.8,5.5,1.4 "Air Conditioning Equipment"

187

" Million Housing Units, Final"  

U.S. Energy Information Administration (EIA) Indexed Site

4 Air Conditioning in U.S. Homes, by Number of Household Members, 2009" 4 Air Conditioning in U.S. Homes, by Number of Household Members, 2009" " Million Housing Units, Final" ,,"Number of Household Members" ,"Total U.S.1 (millions)" ,,,,,,"5 or More Members" "Air Conditioning",,"1 Member","2 Members","3 Members","4 Members" "Total Homes",113.6,31.3,35.8,18.1,15.7,12.7 "Air Conditioning Equipment" "Use Air Conditioning Equipment",94,24.6,30.2,15.1,13.5,10.6 "Have Air Conditioning Equipment But" "Do Not Use It",4.9,1.7,1.5,0.7,0.6,0.5 "Do Not Have Air Conditioning Equipment",14.7,5,4.1,2.3,1.7,1.7 "Type of Air Conditioning Equipment "

188

Application of the VRV Air-Conditioning System Heat Recovery Series in Interior Zone and Analysis of its Energy Saving  

E-Print Network [OSTI]

To reduce the energy consumption of air conditioning systems, we can use the VRV air conditioning system to supply cold loads in the winter for rooms in the construction inner zone where cold loads need to be supplied. The VRV air-conditioning...

Zhang, Q.; Li, D.; Zhang, J.

2006-01-01T23:59:59.000Z

189

Next Generation Rooftop Unit - 2013 Peer Review | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

emrgtech11shen040313.pdf More Documents & Publications A typical commercial rooftop air-conditioning unit (RTU) Credit: Oak Ridge National Lab Next Generation Rooftop Unit...

190

Development of minimum efficiency standards for large capacity air conditioners, and commercial water heaters, refrigerators, and freezers. Final report  

SciTech Connect (OSTI)

The California Energy Resources Conservation and Development Commission has promulgated appliance energy efficiency standards and energy conservation standards for new construction with the objective of reducing energy consumption in the State of California. The following appliance categories are specifically addressed: large capacity air conditioners; commercial water heaters; and commercial refrigerators and freezers. The tasks that have been performed include: an energy use pattern study for the subject equipment; an examination of the size distribution of commercial air conditioning equipment; an examination of the different types of commercial air conditioning systems; an evaluation of the effectiveness of economizers in reducing commercial air conditioning system energy consumption in California; an examination of the effects of oversizing commercial air conditioners; a detailed study of supermarket refrigeration and air conditioning equipment; an evaluation of the economic feasibility of utilizing air conditioner waste heat to heat water; an assessment of the applicability of existing test procedures for small water heaters to large water heaters; and a brief investigation of the marketing and distribution systems for air conditioning and refrigeration equipment. Results of the efforts are described.

Merrill, P.S.; Rettberg, R.J.; Erickson, R.C.; Toor, J.S.

1980-05-01T23:59:59.000Z

191

Manufacture of refrigeration oils  

SciTech Connect (OSTI)

Lubricating oils suitable for use in refrigeration equipment in admixture with fluorinated hydrocarbon refrigerants are produced by solvent extraction of naphthenic lubricating oil base stocks, cooling the resulting extract mixture, optionally with the addition of a solvent modifier, to form a secondary raffinate and a secondary extract, and recovering a dewaxed oil fraction of lowered pour point from the secondary raffinate as a refrigeration oil product. The process of the invention obviates the need for a separate dewaxing operation, such as dewaxing with urea, as conventionally employed for the production of refrigeration oils.

Chesluk, R.P.; Platte, H.J.; Sequeira, A.J.

1981-12-08T23:59:59.000Z

192

Energy-efficiency directory of refrigerators and refrigerator-freezers  

SciTech Connect (OSTI)

Information is presented about the energy costs of operating refrigerators and refrigerator-freezers and includes the type of refrigerator or refrigerator-freezer, the fresh food volume, the freezer volume, the total volume, and the yearly energy cost. The directory lists all currently marketed electric refrigerators and refrigerator-freezers that have Energy Guide labels. The Federal Trade Commission requires manufacturers who distribute refrigerators and refrigerator-freezers to attach Energy Guide labels to appliances manufactured on or after May 19, 1980. The data have been measured by manufacturers and/or their agents according to US Government standard test procedures.

Statt, T.G.; Coggins, J.L.

1981-06-01T23:59:59.000Z

193

Chemically assisted mechanical refrigeration process  

DOE Patents [OSTI]

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-11-24T23:59:59.000Z

194

Chemically assisted mechanical refrigeration process  

DOE Patents [OSTI]

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-06-23T23:59:59.000Z

195

Influence of Mobile Air-Conditioning on Vehicle Emissions and Fuel Consumption:? A Model Approach for Modern Gasoline Cars Used in Europe  

Science Journals Connector (OSTI)

However, apart from studies involving MOBILE6 in the United States (1) and other U. S. studies (2?5), air-conditioning activity in relation to meteorological conditions has not been thoroughly investigated. ... For manual air conditioners, a good setting was sought before the test and the knobs for cooling and ventilation were readjusted if the temperature drifted more than 1 °C. ... The temperatures of the conditioned air range from 5 to 11 °C. ...

Martin F. Weilenmann; Ana-Marija Vasic; Peter Stettler; Philippe Novak

2005-11-04T23:59:59.000Z

196

Thermal performance of an ammonia-water refrigeration system  

SciTech Connect (OSTI)

The conservation and efficient use of energy has led to alternate methods for air conditioning in buildings. Presently, two types of absorption air conditioning systems are widely used: the lithium-bromide-water system and the ammonia-water system. The first type is typically a water fired absorption chiller while the second one is a gas fired chiller. Some of the lithium-bromide-water systems use as a source of heat a stream of hot water supplied from solar collectors at a temperature level of the order of 95-100 {degrees}C. The purpose of this paper is to explore the possibilities to use solar energy to operate an ammonia-water system and to predict its thermodynamic performance. The results indicate that it is feasible to use solar energy to operate an ammonia-water absorption-refrigeration system.

Manrique, J.A. (Inst. Tecnologico y de Estudios Superiores de Monterrey, Dept. of Thermal Engineering, Monterrey, NL (MX))

1991-11-01T23:59:59.000Z

197

Proposal for an Adsorption Solar-Driven Air-Conditioning Unit for Public Offices  

E-Print Network [OSTI]

C, respectively. The C.O.P in both cases was about 0.08. Wang et al. [13] studied a different approach to increase the overall efficiency of the adsorption icemaker, who joined a solar water heater and an icemaker in the same machine. This machine used... the pair Activated carbon-methanol and had 2 m2 of evacuated tube collectors to warm 60 kg of water up to 900C. The daily ice production was about 10 kg when the insolation was about 22 MJm-2. A similar system was studied by Wang et al. [14] who assumed...

Elsamni, O. A.; Sahmarani, K.J.; Obied, F. K.

2010-01-01T23:59:59.000Z

198

Table HC15.7 Air-Conditioning Usage Indicators by Four Most Populated States, 2005  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air-Conditioning Usage Indicators by Four Most Populated States, 2005 7 Air-Conditioning Usage Indicators by Four Most Populated States, 2005 Total.................................................................................. 111.1 7.1 7.0 8.0 12.1 Do Not Have Cooling Equipment.................................... 17.8 1.8 Q Q 4.9 Have Cooling Equipment................................................. 93.3 5.3 7.0 7.8 7.2 Use Cooling Equipment.................................................. 91.4 5.3 7.0 7.7 6.6 Have Equipment But Do Not Use it................................ 1.9 Q N Q 0.6 Type of Air-Conditioning Equipment 1, 2 Central System............................................................. 65.9 1.1 6.4 6.4 5.4 Without a Heat Pump................................................. 53.5 1.1 3.5 5.7 4.9 With a Heat Pump......................................................

199

1991 & 1992 trade-in refrigerator metering project  

SciTech Connect (OSTI)

Under SMUD`s Equipment Efficiency Improvement Program the District offers an incentive of $100 to customers who trade in an older refrigerator in conjunction with the purchase of a new model. More than 40,000 refrigerators have been traded in this program as of January 1993. This program has provided 36.5% of the total reported savings from all SMUD`s conservation programs through April 1993. Of this 36.5% reported savings, 84.7% is attributed to the trading in of an old refrigerator for a new model, and only 15.3% to purchases of a new refrigerators without trading in their older model. In 1992 two laboratory studies were undertaken to quantify energy use of older, close to retirement, domestic residential refrigerators from participants in SMUD`s refrigerator trade-in program. One study focused on annual energy use from older model refrigerators received from this program, and the second study focused on potential energy savings from condenser coil cleaning from this same stock of refrigerators. To determine the performance of these refrigerators, a sample of 79 units was randomly selected for testing. Each unit was tested to obtain annual energy use (kWh/yr) and to document physical and operational conditions. A subset of 28 units from this sample was also tested to determine energy savings as a result of cleaning condenser coils. This was done by comparing test results of annual energy use before and after coil cleaning. These refrigerators were tested to the same conventional procedures (commonly called the {open_quotes}DOE{close_quotes} test, or AHAM test procedures) used to arrive at annual energy use labeled on all new refrigerators. Although laboratory results do not exactly replicate field (in-home) results, they have been found to still be a reasonably good predictor of energy use as reported in a Lawrence Berkeley Laboratory study , discussed in the following section.

Bos, W.

1994-12-31T23:59:59.000Z

200

Guidelines on Airflow and Refrigerant Charge Verification and Diagnostics  

Broader source: Energy.gov (indexed) [DOE]

GUIDELINES ON AIRFLOW AND GUIDELINES ON AIRFLOW AND REFRIGERANT CHARGE VERIFICATION AND DIAGNOSTICS Alliance for Residential Building Innovation David Springer, Davis Energy Group Context  Airflow and refrigerant charge defects in existing air conditioning systems are well documented  Failure to address these problems represents a missed opportunity for home performance contractors  To ensure cost-effective solutions, a systematic approach is needed to quickly and accurately diagnose and resolve problems  Target:  Home performance contractors  HVAC contractors & technicians The Impact of Defects Non-TXV TXV 15% duct leakage 1 -18.10% 23% low airflow -4.70% 50% condenser coil blockage -5.80% 50% evaporator coil blockage 2 -4.60% -4.20% 20% overcharge -3.50% -7.90%

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

E-Print Network 3.0 - authority refrigerator replacement Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: generally replacing their old refrigerator with a larger capacity unit. Rising energy prices and heightened... -95d DEVELOPMENT OF A HIGH EFFICIENCY,...

202

Aggregated Modeling and Control of Air Conditioning Loads for Demand Response  

E-Print Network [OSTI]

1 Aggregated Modeling and Control of Air Conditioning Loads for Demand Response Wei Zhang, Member, IEEE Abstract--Demand response is playing an increasingly impor- tant role in the efficient loads is especially important to evaluate the effec- tiveness of various demand response strategies

Zhang, Wei

203

Theoretical Study of a Novel Control Method of VAV Air-conditioning System Based on MATLAB  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Control Systems for Energy Efficiency and Comfort, Vol. V-2-2 Theoretical Study of a Novel Control Method of VAV Air-conditioning System Based on MATLAB Zhigang Shi Songtao Hu Gang Wang Angui Li Xi?An University...

Shi, Z.; Hu, S.; Wang, G.; Li, A.

2006-01-01T23:59:59.000Z

204

Modeling and Control of Aggregated Air Conditioning Loads Under Realistic Conditions  

E-Print Network [OSTI]

strategy is designed to track a desired demand curve and to ensure a stable and smooth response. I for a large fraction of electric demand. HVAC (Heating, Ventilation and air conditioning) systems and water heaters are examples of TCLs. They use local hysteresis control to maintain either air or water

Zhang, Wei

205

Radon Mitigation in Schools Utilising Heating, Ventilating and Air Conditioning Systems  

Science Journals Connector (OSTI)

......and Air Conditioning Engineers (ASHRAE) standard Ventilation for Acceptable Indoor Air Quality...Two case studies are presented where HVAC technology was implemented for controlling...system in a two-storey building. The HVAC system's controls were restored and modified......

G. Fisher; B. Ligman; T. Brennan; R. Shaughnessy; B.H. Turk; B. Snead

1994-12-01T23:59:59.000Z

206

Optimization of the Fin Heat Pipe for Ventilating and Air Conditioning with a Genetic Algorithm  

E-Print Network [OSTI]

conservation, and it is urgent. At the same time, the energy consumption about air-conditioning of buildings continues to increase and the new wind energy accounts for 4%~12% of the buildings total energy consumption [1]. A heat recovery system for air...

Qian, J.; Sun, D.; Li, G.

2006-01-01T23:59:59.000Z

207

CFD Simulation and Analysis of the Combined Evaporative Cooling and Radiant Ceiling Air-conditioning System  

E-Print Network [OSTI]

, and the ceiling cooling system deals with the other part of sensible loads in the air-conditioned zone, so that the condensation on radiant panels and the insufficiency of cooling capacity can be avoided. The cooling water at 18? used in the cooling coils...

Xiang, H.; Yinming, L.; Junmei, W.

2006-01-01T23:59:59.000Z

208

Test and Reconstruction of Air Conditioning System in a Hotel Lobby  

E-Print Network [OSTI]

Two air conditioning systems are equipped in a hotel lobby. It is found from the field test that the actual air rate is 40% and 16% of the nominal value, respectively, of the two systems, which is far lower than the design requirement. The air rate...

Wang, G.; Hu, Y.; Hu, S.; Chen, Q.

2006-01-01T23:59:59.000Z

209

Smart Operations of Air-Conditioning and Lighting Systems in Government Buildings for Peak Power Reduction  

E-Print Network [OSTI]

During the summer 2007 smart operation strategies for air-conditioning (A/C) and lighting systems were developed and tested in a number of governmental buildings in Kuwait as one of the solutions to reduce the national peak demand for electrical...

Al-Hadban, Y.; Maheshwari, G. P.; Al-Nakib, D.; Al-Mulla, A.; Alasseri, R.

210

A heuristic predictive logic controller applied to hybrid solar air conditioning plant  

Science Journals Connector (OSTI)

This paper shows the development of a heuristic predictive logic controller (HPLoC) applied to a solar air conditioning plant. The plant uses two energy sources, solar and gas, in order to warm up the water. The hot water feeds a single-effect absorption ...

Darine Zambrano; Winston García-Gabín; Eduardo F. Camacho

2007-04-01T23:59:59.000Z

211

Cryogenic optical refrigeration.  

E-Print Network [OSTI]

??This thesis compiles recent achievements in optical refrigeration, cooling a 5 wt. % ytterbium doped yttrium lithium fluoride (Yb+3:YLF) crystal through anti-Stokes fluorescence to a… (more)

Melgaard, Seth

2011-01-01T23:59:59.000Z

212

Risk Factors in Heating, Ventilating, and Air-Conditioning Systems for Occupant Symptoms in  

E-Print Network [OSTI]

cooling units (e.g. , fan coil units) in office buildingsinduction units, fan coil units, individual room packaged ACsystems, cooling tower, fan coil unit, and terminal units.

Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.; Seppanen, O.; Brunner, G.

2007-01-01T23:59:59.000Z

213

Multi-stage Cascaded Stirling Refrigerator  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Multi-stage Cascaded Stirling Refrigerator Multi-stage Cascaded Stirling Refrigerator Los Alamos National Laboratory (LANL) researchers have developed a multi-stage refrigerator,...

214

International Refrigeration: Order (2012-CE-1510) | Department...  

Broader source: Energy.gov (indexed) [DOE]

Refrigeration: Order (2012-CE-1510) July 20, 2012 DOE ordered International Refrigeration Products to pay an 8,000 civil penalty after finding International Refrigeration had...

215

Low-Flow Liquid Desiccant Air Conditioning: General Guidance and Site Considerations  

SciTech Connect (OSTI)

Dehumidification or latent cooling in buildings is an area of growing interest that has been identified as needing more research and improved technologies for higher performance. Heating, ventilating, and air-conditioning (HVAC) systems typically expend excessive energy by using overcool-and-reheat strategies to dehumidify buildings. These systems first overcool ventilation air to remove moisture and then reheat the air to meet comfort requirements. Another common strategy incorporates solid desiccant rotors that remove moisture from the air more efficiently; however, these systems increase fan energy consumption because of the high airside pressure drop of solid desiccant rotors and can add heat of absorption to the ventilation air. Alternatively, liquid desiccant air-conditioning (LDAC) technology provides an innovative dehumidification solution that: (1) eliminates the need for overcooling and reheating from traditional cooling systems; and (2) avoids the increased fan energy and air heating from solid desiccant rotor systems.

Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.

2014-09-01T23:59:59.000Z

216

Influence Of Upper Air Conditions On The Patagonia Icefields L. A. Rasmussen, H. Conway, C. F. Raymond  

E-Print Network [OSTI]

Influence Of Upper Air Conditions On The Patagonia Icefields L. A. Rasmussen, H. Conway, C. F, Second Fig ABSTRACT. Upper-air conditions archived in the NCEP-NCAR Reanalysis have been used cannot be determined, so the investigation is limited to examining relative changes in those upper air

Rasmussen, L.A.

217

Numerical Analysis of Heat and Moisture Transfer in Underground Air-conditioning Systems  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Maximize Comfort: Temperature, Humidity and IAQ Vol.I-6-3 Numerical Analysis of Heat and Moisture Transfer in Underground Air-conditioning Systems Qin Wang, Xiaoping Miao, Baoyi Cheng, Liangkai Fan EIEC, PLA...]. Youming Chen, Shengwei Wang, Ling Zhang. Application of System Identification of Hygrothermal Process in Buildings [M]. Construction and Industry Publishing Company in China, Beijing, 2004. [7]. J.R. Philip, D.A. de Vries. Moisture Movement in Porous...

Wang, Q.; Miao, X.; Cheng, B.; Fan, L.

2006-01-01T23:59:59.000Z

218

Identification of the Flow Resistance Coefficient and Validation of a Building Air Conditioning System  

E-Print Network [OSTI]

for HRC estimation is investigated in this paper. And some conclusions can be got as follows: 1) The MGO method is applicable for S value identification. The method is based on the principle for multi goal optimization. The process can be widely used...ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency, Vol. IV-11-2 Zhijian Hou Identification of the Flow Resistance Coefficient and Validation of a Building Air Conditioning System Zhiwei Lian...

Hou, Z.; Lian, Z.

2006-01-01T23:59:59.000Z

219

Airflow Simulation and Energy Analysis in Ventilated Room with a New Type of Air Conditioning  

E-Print Network [OSTI]

quality will be achieved. Our study aims to simulate airflow in the ventilated room with this new type of air conditioning. Radiation is taken into account by the energy conservation in the system. The following section presents algorithm, thermal..., the governing equations to be solved are the conservation equations for continuity, momentum, and energy as well as the equations for turbulent kinetic energy and its dissipation rate. The buoyancy effect is accounted for by Boussinesq approximation...

Liu, D.; Tang, G.; Zhao, F.

2006-01-01T23:59:59.000Z

220

Printed in the United States of America. Available from National Technical Information Service  

E-Print Network [OSTI]

of Refrigerant Charge .............. 7 3. DESCRIPTION OF TEST UNIT ................... 11 4. DESCRIPTION OF TEST.3 Fan Tests . . . . . . . . . . . . . . . . . . . . . . . . 22 5.4 Refrigerant Charge Tests .... . . .... 3 2.3 Heat Exchanger and Orifice-Type Refrigerant Metering Device Performance ............... 4 2

Oak Ridge National Laboratory

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Table HC6.7 Air-Conditioning Usage Indicators by Number of Household Members, 2005  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air-Conditioning Usage Indicators by Number of Household Members, 2005 7 Air-Conditioning Usage Indicators by Number of Household Members, 2005 Total........................................................................ 111.1 30.0 34.8 18.4 15.9 12.0 Do Not Have Cooling Equipment.......................... 17.8 5.4 5.3 2.7 2.5 2.0 Have Cooling Equipment...................................... 93.3 24.6 29.6 15.7 13.4 10.0 Use Cooling Equipment....................................... 91.4 24.0 29.1 15.5 13.2 9.7 Have Equipment But Do Not Use it...................... 1.9 0.6 0.5 Q 0.2 0.4 Type of Air-Conditioning Equipment 1, 2 Central System................................................... 65.9 15.3 22.6 10.7 9.9 7.3 Without a Heat Pump....................................... 53.5 12.5 17.9 8.7 8.2 6.3 With a Heat Pump............................................ 12.3

222

A novel air-conditioning system for proactive power demand response to smart grid  

Science Journals Connector (OSTI)

Abstract Power demand response is considered as one of the most promising solutions in relieving the power imbalance of an electrical grid that results a series of critical problems to the gird and end-users. In order to effectively make use of the demand response potentials of buildings, this paper presents a novel air-conditioning system with proactive demand control for daily load shifting and real time power balance in the developing smart grid. This system consists of a chilled water storage system (CWS) and a temperature and humidity independent control (THIC) air-conditioning system, which can significantly reduce the storage volume of the chilled water tank and effectively enable a building with more flexibility in changing its electricity usage patterns. The power demand of the proposed air-conditioning system can be flexibly controlled as desired by implementing two types of demand response strategies: demand side bidding (DSB) strategy and demand as frequency controlled reserve (DFR) strategy, in respond to the day-ahead and hour-ahead power change requirements of the grid, respectively. Considerable benefits (e.g., energy and cost savings) can be achieved for both the electricity utilities and building owners under incentive pricing or tariffs. A case study is conducted in a simulation platform to demonstrate the application of the proposed system in an office building.

Chengchu Yan; Xue Xue; Shengwei Wang; Borui Cui

2014-01-01T23:59:59.000Z

223

Control and Diagnostics for Rooftop Units - 2014 BTO Peer Review...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Innovation) This project aims to develop and validate cost-effective methods for rooftop air conditioning unit (RTU) coordination and diagnostics in small commercial buildings. To...

224

Proceedings: Commercial Refrigeration Research Workshop  

SciTech Connect (OSTI)

Improving refrigeration systems for commercial use can enhance both utility load factors and supermarket profits. This workshop has pinpointed research needs in commercial refrigeration and systems integration for a supermarket environment.

None

1984-10-01T23:59:59.000Z

225

Waste Heat Recovery from Refrigeration  

E-Print Network [OSTI]

heat recovery from refrigeration machines is a concept which has great potential for implementation in many businesses. If a parallel requirement for refrigeration and hot water exists, the installation of a system to provide hot water as a by...

Jackson, H. Z.

1982-01-01T23:59:59.000Z

226

Refrigerator: Refrigerators and freezers are not typically constructed to assure that there is no  

E-Print Network [OSTI]

and unstable chemicals only be stored in a lab-safe refrigeration unit that meets National Fire Protection Association 45 ­ Standard on Fire Protection for Laboratories Using Chemicals. #12;Hearing conservation protection which will be furnished by the Institute. Samples of various types of ear muffs, ear caps, and ear

Cohen, Robert E.

227

Refrigeration monitor and alarm system  

SciTech Connect (OSTI)

A monitor is described for a refrigeration system including a heat reclaiming system coupled therewith, comprising: a sensor positioned to detect the level of liquid state refrigerant in the system and provide an electrical output signal therefrom; a digital display for displaying the refrigerant level; first circuit means coupling the digital display to the sensor for actuating the digital display; and lockout means coupled with the sensor for deactivating the heat reclaiming system when a preselected refrigerant level is reached.

Branz, M.A.; Renaud, P.F.

1986-09-23T23:59:59.000Z

228

Helium dilution refrigeration  

E-Print Network [OSTI]

. 1875" OD exchanger Qu ID copper cap Fig. 6. Assembled view of 3He - He dilution refrigerator. 26 The joint thru the tubing wall and the joining of the two sizes of capillary were silver soldered (35/ silver content). A 0. 250" OD tube... the inert atmosphere inside the refrigerator. After removal from the nitrogen atmosphere the graphite support, was 'attached to the still and mixing chamber using Stycast 2850 GT with catalyst g9 ). The mass of the graphite 26 support 1s 11. 62 grams...

McKee, Thomas Raymond

2012-06-07T23:59:59.000Z

229

Enhanced naphthenic refrigeration oils for household refrigerator systems  

SciTech Connect (OSTI)

Due to industry concerns about the successful employment of hydrofluorocarbon-immiscible hydrocarbon oils in refrigeration systems, enhanced naphthenic refrigeration oils have been developed. These products have been designed to be more dispersible with hydrofluorocarbon (HFC) refrigerants, such as R-134a, in order to facilitate lubricant return to the compressor and to ensure proper energy efficiency of the system. Bench tests and system performance evaluations indicate the feasibility of these oils for use in household refrigeration applications. Results of these evaluations are compared with those obtained with polyol esters and typical naphthenic mineral oils employed in chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigeration applications.

Reyes-Gavilan, J.L.; Flak, G.T.; Tritcak, T.R. [Witco Corp., Oakland, NJ (United States); Barbour, C.B. [Americold, Cullman, AL (United States)

1997-12-31T23:59:59.000Z

230

HVAC's Variable Refrigerant Flow (VRF) Technology  

E-Print Network [OSTI]

1 Comfort by Design Steve Jones Commercial Sales Manager for Mitsubishi Southwest Business Unit HVAC?s Variable Refrigerant Flow (VRF) Technology HVAC Industry Overview HVAC Market Dollar Volume $18 Billion Source:;NABH Research....2M Systems Ductless is a small percent of the U.S. HVAC market but current building and energy usage trends indicate a large growth opportunity Determining the Proper Application Worldwide Usage-Opportunity Window Unitary Chillers...

Jones, S.

2012-01-01T23:59:59.000Z

231

Commentary: Air-conditioning as a risk for increased use of healthservices  

SciTech Connect (OSTI)

In this issue of the journal, Preziosi et al. [2004] report the first study to assess differences in the utilization of health care related to the presence of air-conditioning in office workplaces. Although the study was simple and cross-sectional, the data variables from questionnaires, and the findings subject to a variety of questions, the findings are striking enough to deserve clarification. The study used a large random national sample of French women assembled for another purpose (to study antioxidant nutrients and prevention of cancer and cardiovascular disease). Participants reported health services and health events in monthly questionnaires over 1 year, and in one questionnaire in the middle of that period also reported whether air-conditioning was in use at their workplace. Fifteen percent of participants reported air-conditioning at work. Analyses adjusting for age and smoking status of participants found increases in most outcomes assessed: use of specific kinds of physicians, sickness absence, and hospital stays. While the increases in odds ratios (OR) and 95% confidence intervals (CI) were statistically significant for only otorhinolaryngology [OR (95% CI) = 2.33 (1.35-4.04)] and sickness absence [1.70 (1.13-2.58)], other increases were notable--dermatology [1.6 (0.98-2.65)]; hospital stay [1.51 (0.92-2.45)], and pneumonology [2.10 (0.65-6.82)]. The least elevated outcomes were for general practice medicine [0.99 (0.65-1.48)] and global medical visits [1.18 (0.67-2.07)]. [Preziosi et al., 2004 ,(Table 2)] Odds ratios for relatively common health outcomes often lie farther from the null than the risk ratios most useful for quantifying the increase in risk. Risk ratios, or prevalence ratios (PRs, the equivalent measure of effect for cross-sectional data), have seldom been used because of the convenience and availability of logistic regression models that estimate odds ratios. With baseline prevalences ranging up to 85.7% in the data from Preziosi et al. [2004], PRs allow a more appropriate estimate of the increase in each outcome associated with the risk factor of air-conditioning. The increase in prevalence was roughly estimated as [100* (crude PR * adjusted OR/crude OR)-100] %. Based on the data in Table 2 of Preziosi et al. [ 2004], estimates for the increased prevalence associated with air-conditioned offices include increases of 120% in otorhinolaryngology visits, and 40% in sickness absence. If these associated increases represented valid causal relationships, it would indicate enormous costs for employers and for society associated with air-conditioning systems, from increased health care and for reduced workplace productivity from sickness absence, in addition to a large burden of disease on workers.

Mendell, Mark J.

2004-06-01T23:59:59.000Z

232

An Analysis of Price Determination and Markups in the Air-Conditioning and Heating Equipment Industry  

SciTech Connect (OSTI)

In this report we calculate the change in final consumer prices due to minimum efficiency standards, focusing on a standard economic model of the air-conditioning and heating equipment (ACHE) wholesale industry. The model examines the relationship between the marginal cost to distribute and sell equipment and the final consumer price in this industry. The model predicts that the impact of a standard on the final consumer price is conditioned by its impact on marginal distribution costs. For example, if a standard raises the marginal cost to distribute and sell equipment a small amount, the model predicts that the standard will raise the final consumer price a small amount as well. Statistical analysis suggest that standards do not increase the amount of labor needed to distribute equipment the same employees needed to sell lower efficiency equipment can sell high efficiency equipment. Labor is a large component of the total marginal cost to distribute and sell air-conditioning and heating equipment. We infer from this that standards have a relatively small impact on ACHE marginal distribution and sale costs. Thus, our model predicts that a standard will have a relatively small impact on final ACHE consumer prices. Our statistical analysis of U.S. Census Bureau wholesale revenue tends to confirm this model prediction. Generalizing, we find that the ratio of manufacturer price to final consumer price prior to a standard tends to exceed the ratio of the change in manufacturer price to the change in final consumer price resulting from a standard. The appendix expands our analysis through a typical distribution chain for commercial and residential air-conditioning and heating equipment.

Dale, Larry; Millstein, Dev; Coughlin, Katie; Van Buskirk, Robert; Rosenquist, Gregory; Lekov, Alex; Bhuyan, Sanjib

2004-01-30T23:59:59.000Z

233

Demonstration and Testing of ClimaStat for Improved Rooftop Air-Conditioning Efficeincy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Demonstration and Testing of ClimaStat® for Improved Rooftop Air-Conditioning Efficiency Presented at IA Technology Deployment Working Group Meeting March 15, 2012 By Dan Howett, PE Oak Ridge National Laboratory Demonstration/Testing of ClimaStat ® for Improved Efficiency of RTU Air Conditioners * Technology from Advantek Consulting - Patented by Dr. Michael West in 2003. (US Patent #6427454) - Originally demonstrated under DOE's Inventions & Innovations program. * Current demonstration sponsored by DOD's ESTCP program * Uses off-the-shelf components to either... - Modify existing packaged air conditioners, or - Incorporate changes into new RTU equipment before installation * Initial tests show 15% improvement in HVAC efficiency.

234

Demonstration and Testing of ClimaStat for Improved Rooftop Air-Conditioning Efficeincy  

Broader source: Energy.gov (indexed) [DOE]

Demonstration and Testing of ClimaStat® for Improved Rooftop Air-Conditioning Efficiency Presented at IA Technology Deployment Working Group Meeting March 15, 2012 By Dan Howett, PE Oak Ridge National Laboratory Demonstration/Testing of ClimaStat ® for Improved Efficiency of RTU Air Conditioners * Technology from Advantek Consulting - Patented by Dr. Michael West in 2003. (US Patent #6427454) - Originally demonstrated under DOE's Inventions & Innovations program. * Current demonstration sponsored by DOD's ESTCP program * Uses off-the-shelf components to either... - Modify existing packaged air conditioners, or - Incorporate changes into new RTU equipment before installation * Initial tests show 15% improvement in HVAC efficiency.

235

Energy Efficiency and Environmental Impact Analyses of Supermarket Refrigeration Systems  

SciTech Connect (OSTI)

This paper presents energy and life cycle climate performance (LCCP) analyses of a variety of supermarket refrigeration systems to identify designs that exhibit low environmental impact and high energy efficiency. EnergyPlus was used to model refrigeration systems in a variety of climate zones across the United States. The refrigeration systems that were modeled include the traditional multiplex DX system, cascade systems with secondary loops and the transcritical CO2 system. Furthermore, a variety of refrigerants were investigated, including R-32, R-134a, R-404A, R-1234yf, R-717, and R-744. LCCP analysis was used to determine the direct and indirect carbon dioxide emissions resulting from the operation of the various refrigeration systems over their lifetimes. Our analysis revealed that high-efficiency supermarket refrigeration systems may result in up to 44% less energy consumption and 78% reduced carbon dioxide emissions compared to the baseline multiplex DX system. This is an encouraging result for legislators, policy makers and supermarket owners to select low emission, high-efficiency commercial refrigeration system designs for future retrofit and new projects.

Fricke, Brian A [ORNL] [ORNL; Bansal, Pradeep [ORNL] [ORNL; Zha, Shitong [Hillphoenix] [Hillphoenix

2013-01-01T23:59:59.000Z

236

" Million Housing Units, Final"  

U.S. Energy Information Administration (EIA) Indexed Site

8 Air Conditioning in Homes in Northeast Region, Divisions, and States, 2009" 8 Air Conditioning in Homes in Northeast Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Northeast Census Region" ,,,"New England Census Division",,,"Middle Atlantic Census Division" ,"Total U.S.1 (millions)",,"Total New England",,,"Total Middle Atlantic" ,,"Total Northeast",,,"CT, ME, NH, RI, VT" "Air Conditioning",,,,"MA",,,"NY","PA","NJ" "Total Homes",113.6,20.8,5.5,2.5,3,15.3,7.2,4.9,3.2 "Air Conditioning Equipment" "Use Air Conditioning Equipment",94,16.5,3.9,1.9,2,12.6,5.3,4.4,2.9 "Have Air Conditioning Equipment But"

237

" Million Housing Units, Final"  

U.S. Energy Information Administration (EIA) Indexed Site

5 Air Conditioning in U.S. Homes, by Household Income, 2009" 5 Air Conditioning in U.S. Homes, by Household Income, 2009" " Million Housing Units, Final" ,,"Household Income" ,"Total U.S.1 (millions)",,,,,,,,"Below Poverty Line2" ,,"Less than $20,000","$20,000 to $39,999","$40,000 to $59,999","$60,000 to $79,999","$80,000 to $99,999","$100,000 to $119,999","$120,000 or More" "Air Conditioning" "Total Homes",113.6,23.7,27.5,21.2,14.2,9.3,5.7,12,16.9 "Air Conditioning Equipment" "Use Air Conditioning Equipment",94,18.3,22.3,17.9,11.9,8.1,5.1,10.4,12.8 "Have Air Conditioning Equipment But" "Do Not Use It",4.9,1.5,1.3,0.9,0.5,0.2,0.1,0.3,1

238

Energy Conservation and Comfort of Heat Pump Desiccant Air Conditioning System in Actual Living Space in Summer  

E-Print Network [OSTI]

Energy Conservation and Comfort of Heat Pump Desiccant Air Conditioning System in Actual Living and total heat exchanger in terms of both energy conservation and thermal comfort in summer. 1. COP

Miyashita, Yasushi

239

Realisable 10-year reductions in European energy consumption for air conditioning  

Science Journals Connector (OSTI)

Abstract This paper summarises the results of a study to identify and quantify the potential impact of measures and policies to reduce the energy consumption of air conditioning in European countries over a 10-year period. The market penetration of air conditioning in Europe has increased steadily over several decades. On a “business as usual” basis, its energy consumption would increase by over 50% by 2020. Measures to restrict this increase are therefore important, but the savings potential straddles several overlapping areas which are subject to different constraints including those imposed by the replacement rates of systems and products, and the refurbishment rates of existing buildings. This work reported in this paper is based on the use of information from a variety of sources in a highly disaggregated model to assess the “realisable” savings over a 10-year period, taking into account relevant constraints. The paper summarises results at a European level, focussing on those cases that generate the greatest realisable savings. Savings are possible in three areas: improved equipment and system efficiency, reduced cooling loads, and more effective operation. The cases that offer the largest savings provide the basis for recommendations for policy measures, often using existing policy instruments. In addition, areas where further work is needed are identified. More detailed results and information about the study and additional recommendations can be found at http://www.bre.co.uk/searchresults.jsp?category=5&q=energy+management [1].

Roger Hitchin; Christine Pout; David Butler

2015-01-01T23:59:59.000Z

240

Study of solar-assisted thermoelectric technology for automobile air conditioning  

SciTech Connect (OSTI)

An analytical study was conducted to determine the feasibility of employing solar energy assisted thermoelectric (TE) cooling technology in automobile air conditioners. The study addressed two key issues -- power requirements and availability of thermoelectric materials. In this paper a mathematical model was developed to predict the performance of TE air conditioners and to analyze power consumption. Results show that the power required to deliver a cooling capacity of 4 kW (13,680 Btu/h) in a 38 C (100 F) environment will be 9.5 kW electric. Current TE modules suitable for air conditioning are made of bismuth telluride. The element tellurium is expected to be in short supply if TE cooling is widely implemented for auto air conditioning; some options available in this regard were studied and presented in this paper. The photovoltaic (PV) cells, assumed to cover the roof area of a compact car can only generate about 225 W. However, this is more than enough to power a fan to provide air ventilation to the car interior which significantly reduces the peak cooling load when the car is parked in bright sunlight.

Mei, V.C.; Chen, F.C. [Oak Ridge National Lab., Oak Ridge, TN (United States); Mathiprakasam, B.; Heenan, P. [Midwest Research Inst., Kansas City, MO (United States)

1993-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

A genetic rule weighting and selection process for fuzzy control of heating, ventilating and air conditioning systems  

Science Journals Connector (OSTI)

In this paper, we propose the use of weighted linguistic fuzzy rules in combination with a rule selection process to develop accurate fuzzy logic controllers dedicated to the intelligent control of heating, ventilating and air conditioning systems concerning ... Keywords: BEMS, building energy management system, FLC, fuzzy logic controller, Fuzzy logic controllers, GA, genetic algorithm, Genetic algorithms, HVAC systems, HVAC, heating, ventilating, and air conditioning, KB, knowledge base, PMV, predicted mean vote index for thermal comfort, Rule selection, Weighted fuzzy rules

Rafael Alcalá; Jorge Casillas; Oscar Cordón; Antonio González; Francisco Herrera

2005-04-01T23:59:59.000Z

242

Supermarket refrigeration modeling and field demonstration: Interim report  

SciTech Connect (OSTI)

The Electric Power Research Institute (EPRI) has undertaken a project to investigate supermarket refrigeration. The objectives of this project are (1) to develop an energy use and demand model of supermarket refrigeration systems and (2) to carry out an extensive field test of such systems in an operating supermarket. To accomplish these goals, a supermarket owned by Safeway Stores, Inc., and located in Menlo Park, CA, with an existing conventional refrigeration system utilizing single compressor units, was equipped with a state-of-the-art system with multiplexed parallel compressors. The store and both refrigeration systems were thoroughly instrumented and a test schedule was prepared and executed. Presented in this report are the preliminary results of this field test along with the initial validation of the energy use and demand model. 62 figs., 47 tabs.

Walker, D.H.; Deming, G.I.

1989-03-01T23:59:59.000Z

243

Asset Management Equipment Disposal Form -Refrigerant Recovery  

E-Print Network [OSTI]

enters the waste stream with the charge intact (e.g., motor vehicle air conditioners, refrigeratorsAsset Management Equipment Disposal Form - Refrigerant Recovery Safe Disposal Requirements Under refrigeration, cold storage warehouse refrigeration, chillers, and industrial process refrigeration) has to have

Sin, Peter

244

Multilayer Thermionic Refrigeration  

SciTech Connect (OSTI)

A review is presented of our program to construct an efficient solid state refrigerator based on thermionic emission of electrons over periodic barriers in the solid. The experimental program is to construct a simple device with one barrier layer using a three layers: metal-semiconductor-metal. The theoretical program is doing calculations to determine: (i) the optimal layer thickness, and (ii) the thermal conductivity.

Mahan, G.D.

1999-08-30T23:59:59.000Z

245

DOE Closes Investigation into Energy Efficiency of Viking Refrigerator |  

Broader source: Energy.gov (indexed) [DOE]

Closes Investigation into Energy Efficiency of Viking Closes Investigation into Energy Efficiency of Viking Refrigerator DOE Closes Investigation into Energy Efficiency of Viking Refrigerator November 9, 2010 - 7:30pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Viking Range Corporation's refrigerator-freezer model VCSB542. The Department initiated this investigation in response to allegations that the model failed to meet federal energy efficiency standards. After reviewing data provided by Viking for this model, the Department issued a testing demand on June 16, 2010 and initially tested four units, one of which was defective and replaced by a fifth unit. The test results showed that two Viking units failed the federal energy standard for maximum energy use, while two passed. Because of the wide variation in the

246

DOE Closes Investigation into Energy Efficiency of Viking Refrigerator |  

Broader source: Energy.gov (indexed) [DOE]

into Energy Efficiency of Viking into Energy Efficiency of Viking Refrigerator DOE Closes Investigation into Energy Efficiency of Viking Refrigerator November 9, 2010 - 7:30pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Viking Range Corporation's refrigerator-freezer model VCSB542. The Department initiated this investigation in response to allegations that the model failed to meet federal energy efficiency standards. After reviewing data provided by Viking for this model, the Department issued a testing demand on June 16, 2010 and initially tested four units, one of which was defective and replaced by a fifth unit. The test results showed that two Viking units failed the federal energy standard for maximum energy use, while two passed. Because of the wide variation in the

247

Miniature liquid?3He refrigerator  

Science Journals Connector (OSTI)

The use of a cryopump and high?pressure internal storage of the cryogen makes it possible to miniaturize a one?shot recyclable 3He refrigerator while at the same time improving its performance. Because of their simplified interface requirements such refrigerators are readily incorporated into existing 4He cryostats allowing a convenient extension of their operating range down to 0.3 K. An analysis of the parameters describing refrigerator performance (condensation time heat transfer to the 4He bath lifetime and refrigeration power) leads to the definition of an optimized refrigerator. Measured performance characteristics of a miniature [2?l standard temperature and pressure (STP) of 3He] refrigerator used in laboratory and stratospheric balloon?borne experiments are given.

J. P. Torre; G. Chanin

1985-01-01T23:59:59.000Z

248

Vaccine refrigerator testing. Final report  

SciTech Connect (OSTI)

For the Central American Health Clinic Project initiated in 1986, Sandia National Laboratories and the Florida Solar Energy Center recognized the need for a test and evaluation program for vaccine refrigeration systems. At the Florida Solar Energy Center, side-by-side testing of three photovoltaic powered vaccine refrigerators began in 1987. The testing was expanded in 1988 to include a kerosene absorption refrigerator. This report presents observations, conclusions, and recommendations derived from testing the four vaccine refrigeration systems. Information is presented pertaining to the refrigerators, photovoltaic arrays, battery subsystems, charge controllers, and user requirements. This report should be of interest to designers, manufacturers, installers, and users of photovoltaic-powered vaccine refrigeration systems and components.

Ventre, G.G. [Univ. of Central Florida, Orlando, FL (United States); Kilfoyle, D.; Marion, B. [Florida Solar Energy Center, Cape Canaveral, FL (United States)

1990-06-01T23:59:59.000Z

249

Performance and evaluation of gas-engine-driven rooftop air conditioning equipment at the Willow Grove Naval Air Station. Final report (revised October 21, 1996)  

SciTech Connect (OSTI)

The performance was evaluated of a new US cooling technology that has been installed for the first time at a federal facility. The technology is a 15-ton natural gas-engine-driven rooftop air conditioning unit made by Thermo King. Two units were installed to serve the Navy Exchange at Willow Grove. The savings potential at Willow Grove is described and that in the federal sector estimated. Conditions for implementation are discussed. In summary, the new technology is generally cost-effective at sites where marginal electricity cost (per MBtu at the meter) is more than 4 times the marginal gas cost (per MBtu at the meter) and annual full-load-equivalent cooling hours exceed 2,000.

Armstrong, P.R.; Katipamula, S.

1996-10-01T23:59:59.000Z

250

STATEMENT OF CONSIDERATIONS REQUEST BY UNITED TECHNOLOGIES RESEARCH CENTER FOR AN  

Broader source: Energy.gov (indexed) [DOE]

COOPERATIVE AGREEMENT COOPERATIVE AGREEMENT DE-EE0003955; DOE WAIVER NO. W(A)2011-014; CH1598 ~ The Petitioner, United Technologies Research Center (UTRC), has requested an Advance Waiver of the Government's domestic and foreign rights to inventions in the above cited research and development cooperative agreement issued by DOE's National Energy Technology Laboratory (NETL). See attached UTRC's Petition, Answer I. Subj ect of the R&D Contract Title: Natural Refrigerant Very High Efficiency HV AC Systems The objective of the cooperative agreement is to design, develop and demonstrate a safe low Global Wanning Potential (GWP) Very High Perfonnance Air-Conditioning (VHPAC) residential system. The 4 stage project will include design, analysis, fabrication and commissioning of a component test rigs to facilitate proof-of-concept testing of proposed

251

NICE3: Industrial Refrigeration System  

SciTech Connect (OSTI)

Energy Concepts has developed an absorption-augmented system as a cost-effective means of achieving more cooling capacity with a substantial reduction in energy consumption and greenhouse gas emissions for industrial refrigeration. It cuts fuel consumption by 30% by combining an internal combustion engine with a mechanical compression refrigeration system and an absorption refrigeration system. The absorption system is powered by engine waste heat. Conventional industrial refrigeration uses mechanical vapor compression, powered by electric motors, which results in higher energy costs. By the year 2010, the new system could cut fuel consumption by 19 trillion Btu and greenhouse emissions by more than 1 million tons per year.

Simon, P.

1999-09-29T23:59:59.000Z

252

Energy Impact of Residential Ventilation Norms in the United States  

E-Print Network [OSTI]

legal responsibility for the accuracy, completeness, or usefulness of any information, apparatus by the American Society of Heating, Refrigerating and Air- conditioning Engineers (ASHRAE). This standard does but about the environment in which they lived. Historically, people have ventilated buildings to provide

253

Energy Performance Comparison of Heating and Air Conditioning Systems for Multi-Family Residential Buildings  

SciTech Connect (OSTI)

The type of heating, ventilation and air conditioning (HVAC) system has a large impact on the heating and cooling energy consumption in multifamily residential buildings. This paper compares the energy performance of three HVAC systems: a direct expansion (DX) split system, a split air source heat pump (ASHP) system, and a closed-loop water source heat pump (WSHP) system with a boiler and an evaporative fluid cooler as the central heating and cooling source. All three systems use gas furnace for heating or heating backup. The comparison is made in a number of scenarios including different climate conditions, system operation schemes and applicable building codes. It is found that with the minimum code-compliant equipment efficiency, ASHP performs the best among all scenarios except in extremely code climates. WSHP tends to perform better than the split DX system in cold climates but worse in hot climates.

Wang, Weimin; Zhang, Jian; Jiang, Wei; Liu, Bing

2011-07-31T23:59:59.000Z

254

New Automotive Air Conditioning System Simulation Tool Developed in MATLAB/Simulink  

SciTech Connect (OSTI)

Further improvements in vehicle fuel efficiency require accurate evaluation of the vehicle's transient total power requirement. When operated, the air conditioning (A/C) system is the largest auxiliary load on a vehicle; therefore, accurate evaluation of the load it places on the vehicle's engine and/or energy storage system is especially important. Vehicle simulation software, such as 'Autonomie,' has been used by OEMs to evaluate vehicles' energy performance. A transient A/C simulation tool incorporated into vehicle simulation models would also provide a tool for developing more efficient A/C systems through a thorough consideration of the transient A/C system performance. The dynamic system simulation software Matlab/Simulink was used to develop new and more efficient vehicle energy system controls. The various modeling methods used for the new simulation tool are described in detail. Comparison with measured data is provided to demonstrate the validity of the model.

Kiss, T.; Chaney, L.; Meyer, J.

2013-07-01T23:59:59.000Z

255

LiCl dehumidifier/LiBr absorption chiller hybrid air conditioning system with energy recovery  

SciTech Connect (OSTI)

This invention relates to a hybrid air conditioning system that combines a solar powered LiCl dehumidifier with a LiBr absorption chiller. The desiccant dehumidifier removes the latent load by absorbing moisture from the air, and the sensible load is removed by the absorption chiller. The desiccant dehumidifier is coupled to a regenerator and the desiccant in the regenerator is heated by solar heated hot water to drive the moisture therefrom before being fed back to the dehumidifier. The heat of vaporization expended in the desiccant regenerator is recovered and used to partially preheat the driving fluid of the absorption chiller, thus substantially improving the overall COP of the hybrid system.

Ko, S.M.

1980-06-03T23:59:59.000Z

256

LiCl dehumidifier LiBr absorption chiller hybrid air conditioning system with energy recovery  

SciTech Connect (OSTI)

This invention relates to a hybrid air conditioning system that combines a solar powered LiCl dehumidifier with a LiBr absorption chiller. The desiccant dehumidifier removes the latent load by absorbing moisture from the air, and the sensible load is removed by the absorption chiller. The desiccant dehumidifier is coupled to a regenerator and the desiccant in the regenerator is heated by solar heated hot water to drive the moisture therefrom before being fed back to the dehumidifier. The heat of vaporization expended in the desiccant regenerator is recovered and used to partially preheat the driving fluid of the absorption chiller, thus substantially improving the overall COP of the hybrid system. 4 figs.

Ko, S.M.

1980-06-03T23:59:59.000Z

257

Evaluation Framework and Analyses for Thermal Energy Storage Integrated with Packaged Air Conditioning  

SciTech Connect (OSTI)

Few third-party guidance documents or tools are available for evaluating thermal energy storage (TES) integrated with packaged air conditioning (AC), as this type of TES is relatively new compared to TES integrated with chillers or hot water systems. To address this gap, researchers at the National Renewable Energy Laboratory conducted a project to improve the ability of potential technology adopters to evaluate TES technologies. Major project outcomes included: development of an evaluation framework to describe key metrics, methodologies, and issues to consider when assessing the performance of TES systems integrated with packaged AC; application of multiple concepts from the evaluation framework to analyze performance data from four demonstration sites; and production of a new simulation capability that enables modeling of TES integrated with packaged AC in EnergyPlus. This report includes the evaluation framework and analysis results from the project.

Kung, F.; Deru, M.; Bonnema, E.

2013-10-01T23:59:59.000Z

258

Impact of Vehicle Air-Conditioning on Fuel Economy, Tailpipe Emissions, and Electric Vehicle Range: Preprint  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Vehicle Air- Vehicle Air- Conditioning on Fuel Economy, Tailpipe Emissions, and Electric Vehicle Range Preprint September 2000 * NREL/CP-540-28960 R. Farrington and J. Rugh To Be Presented at the Earth Technologies Forum Washington, D.C. October 31, 2000 National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401-3393 NREL is a U.S. Department of Energy Laboratory Operated by Midwest Research Institute * * * * Battelle * * * * Bechtel Contract No. DE-AC36-99-GO10337 NOTICE The submitted manuscript has been offered by an employee of the Midwest Research Institute (MRI), a contractor of the US Government under Contract No. DE-AC36-99GO10337. Accordingly, the US Government and MRI retain a nonexclusive royalty-free license to publish or reproduce the published

259

E-Print Network 3.0 - adiabatic demagnetization refrigerator...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

refrigerator Search Powered by Explorit Topic List Advanced Search Sample search results for: adiabatic demagnetization refrigerator...

260

Analysis of historical residential air-conditioning equipment sizing using monitored data  

SciTech Connect (OSTI)

Monitored data were analyzed to determine whether residential air conditioners in the Pacific Northwest historically have been sized properly to meet or slightly exceed actual cooling requirements. Oversizing air-conditioning equipment results in a loss of efficiency because of increased cycling and also lowers humidity control. On the other hand, the penalty of undersizing air-conditioning equipment may be some loss of comfort during extremely hot weather. The monitored data consist of hourly space-conditioning electrical energy use and internal air temperature data collected during the past 7 years from 75 residences in the Pacific Northwest. These residences are equipped with central air conditioners or heat pumps. The periods with the highest cooling energy use were analyzed for each site. A standard industry sizing methodology was used for each site to determine a sizing estimate. Both the sizing recommendation based on Manual J and peak monitored loads are compared to the capacity of the installed equipment for each site to study how the actual capacity differed from both the estimate of proper sizing and from actual demands. Characteristics of the maximum cooling loads are analyzed here to determine which conditions put the highest demand on the air conditioner. Specifically, internal air temperature data are used to determine when the highest cooling loads occur, at constant thermostat settings or when the thermostat was set down. This analysis of monitored data also provides insight into the extent that occupant comfort may be affected by undersizing air conditioners. The findings of this research indicate that cooling equipment historically has often but not always been oversized beyond industry-recommended levels. However, some occupants in homes with undersized, properly sized, and, in rare occasions, even oversized cooling equipment appear to suffer because the cooling equipment cannot always provide adequate cooling. Key findings are summarized.

Lucas, R.G.

1993-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Energy use test procedures for appliances: A case study of Japanese refrigerators  

SciTech Connect (OSTI)

The energy test procedure provides a consistent measurement of refrigerator energy consumption, which can be used by engineers, utility forecasters, and consumers. The U.S. and Japanese test procedures for refrigerators differ significantly, so it is impossible to directly compare the performance of unique features, or even determine which units are more efficient. The energy use of 12 Japanese refrigerators (of which 9 were unique models) were measured under the U.S. DOE energy test procedure and compared to that reported by the manufacturers under the Japanese test procedure. The Japanese refrigerators used substantially more electricity with the DOE test.

Meier, A.K.

1987-06-01T23:59:59.000Z

262

PHYSICAL AND CHEMICAL CHANGES OF PINK SHRIMP, PANDALUS BOREALIS, HELD IN CARBON DIOXIDE MODIFIED REFRIGERATED  

E-Print Network [OSTI]

. Holding Tank and Refrigeration Unit A 568-1 (150-gal) fiber glass holding tank was connectedPHYSICAL AND CHEMICAL CHANGES OF PINK SHRIMP, PANDALUS BOREALIS, HELD IN CARBON DIOXIDE MODIFIED ahrimp,PandaluB borealis, were held in carbon dioxide modified refrigerated seawater for 12.5 days

263

Modular thermoacoustic refrigerator  

Science Journals Connector (OSTI)

A thermoacousticrefrigerator was built to explore scaling to large heat flux. The refrigerator was constructed according to a modular design so that various stack heat exchanger and resonator sections are easily interchangeable. The resonator is driven by a commercial 10?in. woofer. Initial tests using pure helium gas as the working fluid and steel honeycomb (0.8?mm cell) for the stack pumped 60 W of heat against a 10?°C temperature gradient. Measurements of heat flux and efficiency will be reported as functions of stack structure (e.g. pore size and shape) and will be compared with theoretical predictions.

Steven R. Murrell; George Mozurkewich

1993-01-01T23:59:59.000Z

264

The refrigerator revolution  

SciTech Connect (OSTI)

This article discusses how a simple, new technology threw the best-laid plans of the chemical and refrigerator industries into disarray-and provided a new perspective on how future environmental agreements can be reached. In recent years, a series of massive business mergers has mesmerized the industrial world. However in the early 1990s a German environmentalist, triggered global reprocussions in the wake of the mandate to phase out the use of ozone depleting substances. The economic and political background of this is explained in detail.

Ayres, E.; French, H.

1996-09-01T23:59:59.000Z

265

Semiconductor-based optical refrigerator  

DOE Patents [OSTI]

Optical refrigerators using semiconductor material as a cooling medium, with layers of material in close proximity to the cooling medium that carries away heat from the cooling material and preventing radiation trapping. In addition to the use of semiconducting material, the invention can be used with ytterbium-doped glass optical refrigerators.

Epstein, Richard I. (Santa Fe, NM); Edwards, Bradley C. (Nekoosa, WI); Sheik-Bahae, Mansoor (Albuquerque, NM)

2002-01-01T23:59:59.000Z

266

Load Forecasting of Supermarket Refrigeration  

E-Print Network [OSTI]

energy system. Observed refrigeration load and local ambient temperature from a Danish su- permarket renewable energy, is increasing, therefore a flexible energy system is needed. In the present ThesisLoad Forecasting of Supermarket Refrigeration Lisa Buth Rasmussen Kongens Lyngby 2013 M.Sc.-2013

267

Improving the energy efficiency of refrigerators in India  

SciTech Connect (OSTI)

Five state-of-the-art, production refrigerators from different manufacturers in India were subjected to a variety of appliance rating and performance evaluation test procedures in an engineering laboratory. Cabinet heat loss, compressor calorimeter, high-ambient pull-down, and closed-door energy consumption tests were performed on each unit to assess the current status of commercially available Indian refrigerators and refrigerator component efficiencies. Daily energy consumption tests were performed at nominal line voltages and at 85% and 115% of nominal voltage to assess the effect of grid voltage variations. These test results were also used to indicate opportunities for effective improvements in energy efficiency. A widely distributed ``generic`` computer model capable of simulating single-door refrigerators with a small interior freezer section was used to estimate cabinet heat loss rates and closed door energy consumption values from basic cabinet and refrigeration circuit inputs. This work helped verify the model`s accuracy and potential value as a tool for evaluating the energy impact of proposed design options. Significant differences ranging from 30 to 90% were seen in the measured performance criterion for these ``comparable`` refrigerators suggesting opportunities for improvements in individual product designs. Modeled cabinet heat loadings differed from experimentally extrapolated values in a range from 2--29%, and daily energy consumption values estimated by the model differed from laboratory data by as little as 3% or as much as 25%, which indicates that refinement of the model may be needed for this single-door refrigerator type. Additional comparisons of experimentally measured performance criteria such as % compressor run times and compressor cycling rates to modeled results are given. The computer model is used to evaluate the energy saving impact of several modest changes to the basic Indian refrigerator design.

Sand, J.R.; Vineyard, E.A. [Oak Ridge National Lab., TN (United States); Bohman, R.H. [Consulting Engineer, Cedar Rapids, IA (United States)

1995-04-01T23:59:59.000Z

268

An experimental study of waste heat recovery from a residential refrigerator  

SciTech Connect (OSTI)

This paper describes the design, construction, and testing of an integrated heat recovery system which has been designed both to enhance the performance of a residential refrigerator and simultaneously to provide preheated water for an electric hot water heater. A commercial, indirect-heated hot water tank was retrofitted with suitable tubing to permit it to serve as a water cooled condenser for a residential refrigerator. This condenser operates in parallel with the air-cooled condenser tubing of the refrigerator so that either one or the other is active when the refrigerator is running. The refrigerator was housed in a controlled-environment chamber, and it was instrumented so that its performance could be monitored carefully in conjunction with the water pre-heating system. The system has been tested under a variety of hot water usage protocols, and the resulting data set has provided significantly insight into issues associated with commercial implementation of the concept. For the case of no water usage, the system was able to provide a 35 C temperature rise in the storage tank after about 100 hours of continuous operation, with no detectable deterioration of the refrigerator performance. Preliminary tests with simulations of high water usage, low water usage, and family water usage indicate a possible 18--20% energy savings for hot water over a long period of operation. Although the economic viability for such a system in a residential environment would appear to be sub-marginal, the potential for such a system associated with commercial-scale refrigeration clearly warrants further study, particularly for climates for which air conditioning heat rejection is highly seasonal.

Clark, R.A.; Smith, R.N.; Jensen, M.K. [Rensselaer Polytechnic Inst., Troy, NY (United States)

1996-12-31T23:59:59.000Z

269

Malone cycle refrigerator development  

SciTech Connect (OSTI)

This paper describes the progress made in demonstrating a Malone Cycle Refrigerator/Freezer. The Malone cycle is similar to the Stirling cycle but uses a supercritical fluid in place of real gas. In the approach, solid-metal diaphragms are used to seal and sweep the working volumes against the high working fluid pressures required in Malone cycle machines. This feature eliminates the friction and leakage that accounted for nearly half the losses in the best piston-defined Malone cycle machines built to date. The authors successfully built a Malone cycle refrigerator that: (1) used CO{sub 2} as the working fluid, (2) operated at pressures up to 19.3 Mpa (2,800 psi), (3) achieved a cold end metal temperatures of {minus}29 C ({minus}20 F), and (4) produced over 400 Watts of cooling at near ambient temperatures. The critical diaphragm components operated flawlessly throughout characterization and performance testing, supporting the conclusion of high reliability based on analysis of fatigue date and actual strain measurements.

Shimko, M.A.; Crowley, C.J.

1999-07-01T23:59:59.000Z

270

Helium dilution refrigeration system  

DOE Patents [OSTI]

A helium dilution refrigeration system operable over a limited time period, and recyclable for a next period of operation. The refrigeration system is compact with a self-contained pumping system and heaters for operation of the system. A mixing chamber contains .sup.3 He and .sup.4 He liquids which are precooled by a coupled container containing .sup.3 He liquid, enabling the phase separation of a .sup.3 He rich liquid phase from a dilute .sup.3 He-.sup.4 He liquid phase which leads to the final stage of a dilution cooling process for obtaining low temperatures. The mixing chamber and a still are coupled by a fluid line and are maintained at substantially the same level with the still cross sectional area being smaller than that of the mixing chamber. This configuration provides maximum cooling power and efficiency by the cooling period ending when the .sup.3 He liquid is depleted from the mixing chamber with the mixing chamber nearly empty of liquid helium, thus avoiding unnecessary and inefficient cooling of a large amount of the dilute .sup.3 He-.sup.4 He liquid phase.

Roach, Patrick R. (Darien, IL); Gray, Kenneth E. (Naperville, IL)

1988-01-01T23:59:59.000Z

271

Low-Flow Liquid Desiccant Air-Conditioning: Demonstrated Performance and Cost Implications  

SciTech Connect (OSTI)

Cooling loads must be dramatically reduced when designing net-zero energy buildings or other highly efficient facilities. Advances in this area have focused primarily on reducing a building's sensible cooling loads by improving the envelope, integrating properly sized daylighting systems, adding exterior solar shading devices, and reducing internal heat gains. As sensible loads decrease, however, latent loads remain relatively constant, and thus become a greater fraction of the overall cooling requirement in highly efficient building designs, particularly in humid climates. This shift toward latent cooling is a challenge for heating, ventilation, and air-conditioning (HVAC) systems. Traditional systems typically dehumidify by first overcooling air below the dew-point temperature and then reheating it to an appropriate supply temperature, which requires an excessive amount of energy. Another dehumidification strategy incorporates solid desiccant rotors that remove water from air more efficiently; however, these systems are large and increase fan energy consumption due to the increased airside pressure drop of solid desiccant rotors. A third dehumidification strategy involves high flow liquid desiccant systems. These systems require a high maintenance separator to protect the air distribution system from corrosive desiccant droplet carryover and so are more commonly used in industrial applications and rarely in commercial buildings. Both solid desiccant systems and most high-flow liquid desiccant systems (if not internally cooled) add sensible energy which must later be removed to the air stream during dehumidification, through the release of sensible heat during the sorption process.

Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.; Lowenstein, A.

2014-09-01T23:59:59.000Z

272

An experimental system for advanced heating, ventilating and air conditioning (HVAC) control  

Science Journals Connector (OSTI)

While having the potential to significantly improve heating, ventilating and air conditioning (HVAC) system performance, advanced (e.g., optimal, robust and various forms of adaptive) controllers have yet to be incorporated into commercial systems. Controllers consisting of distributed proportional-integral (PI) control loops continue to dominate commercial HVAC systems. Investigation into advanced HVAC controllers has largely been limited to proposals and simulations, with few controllers being tested on physical systems. While simulation can be insightful, the only true means for verifying the performance provided by HVAC controllers is by actually using them to control an HVAC system. The construction and modeling of an experimental system for testing advanced HVAC controllers, is the focus of this article. A simple HVAC system, intended for controlling the temperature and flow rate of the discharge air, was built using standard components. While only a portion of an overall HVAC system, it is representative of a typical hot water to air heating system. In this article, a single integrated environment is created that is used for data acquisition, controller design, simulation, and closed loop controller implementation and testing. This environment provides the power and flexibility needed for rapid prototyping of various controllers and control design methodologies.

Michael Anderson; Michael Buehner; Peter Young; Douglas Hittle; Charles Anderson; Jilin Tu; David Hodgson

2007-01-01T23:59:59.000Z

273

Reliability of Heat Pumps Containing R410-A Refrigerant  

E-Print Network [OSTI]

Ester (POE) oils used with HFC refrigerants will break down into acid and alcohol when exposed to heat. Manufacturers have many tools to establish reliability of a product prior to mass production. Units and compressors can be nm on life tests. Prototype...

McJimsey, B. A.; Cawley, D.

1998-01-01T23:59:59.000Z

274

Automated control and data acquisition for a small dilution refrigerator  

Science Journals Connector (OSTI)

An automatic temperature controller and data acquisition system for use with a dilution refrigerator is described. The unit is controlled by a 16?bit home microcomputer and operates and reads a resistance bridge capacitance bridge and temperature controller. Interfacing is achieved with common components and minimum additional wiring. Flexibility is retained in the software to allow application to several types of measurements.

David G. Haase

1981-01-01T23:59:59.000Z

275

Cryogenic refrigeration apparatus  

DOE Patents [OSTI]

A technique for producing a cold environment in a refrigerant system in which input fluid from a compressor at a first temperature is introduced into an input channel of the system and is pre-cooled to a second temperature for supply to one of at least two stages of the system, and to a third temperature for supply to another stage thereof. The temperatures at such stages are reduced to fourth and fifth temperatures below the second and third temperatures, respectively. Fluid at the fourth temperature from the one stage is returned through the input channel to the compressor and fluid at the fifth temperature from the other stage is returned to the compressor through an output channel so that pre-cooling of the input fluid to the one stage occurs by regenerative cooling and counterflow cooling and pre-cooling of the input fluid to the other stage occurs primarily by counterflow cooling.

Crunkleton, James A. (Cambridge, MA)

1992-01-01T23:59:59.000Z

276

The Quantum Absorption Refrigerator  

E-Print Network [OSTI]

A quantum absorption refrigerator driven by noise is studied with the purpose of determining the limitations of cooling to absolute zero. The model consists of a working medium coupled simultaneously to hot, cold and noise baths. Explicit expressions for the cooling power are obtained for Gaussian and Poisson white noise. The quantum model is consistent with the first and second laws of thermodynamics. The third law is quantified, the cooling power J_c vanishes as J_c proportional to T_c^{alpha}, when T_c approach 0, where alpha =d+1 for dissipation by emission and absorption of quanta described by a linear coupling to a thermal bosonic field, where d is the dimension of the bath.

Amikam Levy; Ronnie Kosloff

2011-09-04T23:59:59.000Z

277

Synopsis of residential refrigerator/freezer alternative refrigerants evaluation  

SciTech Connect (OSTI)

The experimental testing on residential refrigerator/freezers (R/Fs) is summarized in this paper. R/F testing focused on two areas: alternative refrigerants and equipment configurations. The refrigerants evaluated consisted of single components, azeotropes, and zeotropes derived from hydrofluorocarbons (HFCs) and hydrocarbons (HCs). These refrigerants were evaluated in conventional and unconventional R/F designs. Major and minor design modifications were studied. Minor modifications consisted of various capillary tube lengths, door insulations, and compressors, while major modifications included two-evaporator and two-cycle R/F systems. Results obtained from testing the two-cycle system will be discussed in a later paper. This paper presents the experimental results of alternative technologies evaluated as replacements for ozone depleting chemicals.

Baskin, E. [Environmental Protection Agency, Research Triangle Park, NC (United States)

1998-12-31T23:59:59.000Z

278

Problem of Vain Energy Consumption in a VAV Air Conditioning System Shared By an Inner Zone and Exterior Zone  

E-Print Network [OSTI]

in winter and summer. Taking a practical project as example, this paper analyzes the energy consumption of a VAV air conditioning system that is shared by inner zone and exterior zone. The paper also points out the serious problem of useless energy...

Wenji, G.; Ling, C.; Dongdong, L.; Mei, S.; Li, Z.

2006-01-01T23:59:59.000Z

279

" Million Housing Units, Final"  

U.S. Energy Information Administration (EIA) Indexed Site

9 Air Conditioning in Homes in Midwest Region, Divisions, and States, 2009" 9 Air Conditioning in Homes in Midwest Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Midwest Census Region" ,,,"East North Central Census Division",,,,,"West North Central Census Division" ,,,"Total East North Central",,,,,"Total West North Central" ,"Total U.S.1 (millions)" ,,"Total Midwest",,,,," IN, OH",,,"IA, MN, ND, SD" "Air Conditioning",,,,"IL","MI","WI",,,"MO",,"KS, NE" "Total Homes",113.6,25.9,17.9,4.8,3.8,2.3,7,8.1,2.3,3.9,1.8 "Air Conditioning Equipment" "Use Air Conditioning Equipment",94,22.4,15,4.3,3.1,1.8,5.9,7.4,2.3,3.4,1.7

280

Experimental Research and Performance Analysis of a Solar-Powered Air-conditioning System in a Green Building  

E-Print Network [OSTI]

temperature variations of solar collector arrays, heat storage tank and adsorption chillers as well as refrigerating output variations of the system. Experimental results show that adsorption chillers have the advantages of low driving temperature, stability...

Zhai, X.; Wang, R.; Dai, Y.; Wu, J.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

MagLab - Dilution Refrigerator  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

in science. Using a condensationevaporation cycle not unlike that of a kitchen refrigerator, a dil fridge takes 4.2 K liquid helium way down to 1.5 K. The animation below...

282

The Explorationon the Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and the Mechanism of the Theoretical Mixed Refrigeration Cycl  

E-Print Network [OSTI]

expansion valves and an ejector. Mass and energy conservation equations are established for the air handling process and the theoretical mixed refrigeration cycle is analyzed. The state properties in the thermal processes and system performance... systems, Innovative technologies to reduce building energy consumption. In a room with a conventional air conditioner, the supplied air is not evenly distributed and there may be a draft sensation, which may cause “air-conditioning symptoms...

Zhao,L.; Zhao,X.; Hu,A.

2014-01-01T23:59:59.000Z

283

Analysis of simultaneous cooling and heating in supermarket refrigeration systems.  

E-Print Network [OSTI]

?? In this master thesis project, conventional supermarket refrigeration systems using R404A are compared with refrigeration system solutions using natural refrigerants such as carbon dioxide… (more)

Marigny, Johan

2011-01-01T23:59:59.000Z

284

Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862  

E-Print Network [OSTI]

Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862

2014-01-01T23:59:59.000Z

285

Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure  

E-Print Network [OSTI]

Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure

2012-01-01T23:59:59.000Z

286

Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel  

E-Print Network [OSTI]

Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

2012-01-01T23:59:59.000Z

287

Analysis of heat recovery in supermarket refrigeration system using carbon dioxide as refrigerant.  

E-Print Network [OSTI]

?? The aim of this study is to investigate the heat recovery potential in supermarket refrigeration systems using CO2 as refrigerants. The theoretical control strategy… (more)

Abdi, Amir

2014-01-01T23:59:59.000Z

288

GEA Refrigeration Technologies / GEA Refrigeration Germany GmbH Wolfgang Dietrich / Dr. Ole Fredrich  

E-Print Network [OSTI]

GEA Refrigeration Technologies / GEA Refrigeration Germany GmbH Wolfgang Dietrich / Dr. Ole Technologies3 Achema 2012 // heat pumps using ammonia Industrial demand on heat in Germany Heatdemandin

Oak Ridge National Laboratory

289

Super efficient refrigeration systems: Two non-CFC designs ready for commercialization  

SciTech Connect (OSTI)

Two high-efficiency prime movers for refrigeration are ready for field testing and commercialization. Either machine, combined with other advanced measures, could result in a CFC-free refrigerator using significantly less energy than units meeting the 1993 US efficiency standards. The first design is a linear motor/compressor that manufacturers could substitute for the standard rotating motor/compressor in a conventional refrigerator. The second design is a Stirling-cycle refrigeration machine that is self contained and uses helium gas as the working fluid. The results of prototype testing, the inherent simplicity of both machines, and their virtually frictionless operation point to economical and reliable service. If these features are confirmed in further testing now being conducted by appliance and compressor manufacturers, these machines will be strong candidates for inclusion in super efficient refrigerator designs over the next few years.

Stickney, B.L.

1992-12-31T23:59:59.000Z

290

Indoor unit for electric heat pump  

DOE Patents [OSTI]

An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

1984-05-22T23:59:59.000Z

291

Refrigerator-Freezer Appendix A1 | Department of Energy  

Energy Savers [EERE]

Refrigerator-Freezer Appendix A1 Refrigerator-Freezer Appendix A1 Residential Refrigerator-Freezer Appendix A1 - v2.8.xlsx More Documents & Publications Refrigerators and...

292

An Evaluation of the Effects of Refrigerant Charge on a Residential Central Air Conditioner with Orifice Expansion  

E-Print Network [OSTI]

Section 2.3 Outdoor Test Section 2.5 Refrigerant Side 2.6 Data Acquisition 2.9 Refrigerant Charging Procedures 2.11 References 2.13 3 NOMINAL SIZE ORIFICE RESULTS 3.1 System Performance Data 3.1 Detailed System Data 3.10 4 RESULTS FOR ALTERNATE ORIFICES 4... circuit to allow easy disassembly of the unit without any loss of refrigerant charge. Charging taps in each section of the circuitry allowed purging and charging of each section independently. 2.6 ro Figure 2.3 - Schematic of the refrigerant circuit...

O'Neal, D. L.; Ramsey, C. J.; Farzad, M.

1989-01-01T23:59:59.000Z

293

China Refrigerator Information Label: Specification Development and Potential Impact  

E-Print Network [OSTI]

Household Refrigerator Market and Energy Conservation Regulations in Japan.Household Refrigerator Market and Energy Conservation Regulations in Japan

Fridley, David

2008-01-01T23:59:59.000Z

294

Floating Refrigerant Loop Based on R-134a Refrigerant Cooling of High-Heat Flux Electronics  

SciTech Connect (OSTI)

The Oak Ridge National Laboratory (ORNL) Power Electronics and Electric Machinery Research Center (PEEMRC) have been developing technologies to address the thermal issues associated with hybrid vehicles. Removal of the heat generated from electrical losses in traction motors and their associated power electronics is essential for the reliable operation of motors and power electronics. As part of a larger thermal control project, which includes shrinking inverter size and direct cooling of electronics, ORNL has developed U.S. Patent No. 6,772,603 B2, ''Methods and Apparatus for Thermal Management of Vehicle Systems and Components'' [1], and patent pending, ''Floating Loop System for Cooling Integrated Motors and Inverters Using Hot Liquid Refrigerant'' [2]. The floating-loop system provides a large coefficient of performance (COP) for hybrid-drive component cooling. This loop (based on R-134a) is integrated with a vehicle's existing air-conditioning (AC) condenser, which dissipates waste heat to the ambient air. Because the temperature requirements for cooling of power electronics and electric machines are not as low as that required for passenger compartment air, this adjoining loop can operate on the high-pressure side of the existing AC system. This arrangement also allows the floating loop to run without the need for the compressor and only needs a small pump to move the liquid refrigerant. For the design to be viable, the loop must not adversely affect the existing system. The loop should also provide a high COP, a flat-temperature profile, and low-pressure drop. To date, the floating-loop test prototype has successfully removed 2 kW of heat load in a 9 kW automobile passenger AC system with and without the automotive AC system running. The COP for the tested floating-loop system ranges from 40-45, as compared to a typical AC system COP of about 2-4. The estimated required waste-heat load for future hybrid applications is 5.5 kW and the existing system could be easily scaleable for this larger load.

Lowe, K.T.

2005-10-07T23:59:59.000Z

295

Thermoelectric refrigerator having improved temperature stabilization means  

DOE Patents [OSTI]

A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature, but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized.

Falco, Charles M. (Woodridge, IL)

1982-01-01T23:59:59.000Z

296

Cospolich Refrigerator: Order (2013-CE-5314)  

Broader source: Energy.gov [DOE]

DOE ordered Cospolich Refrigerator Co, Inc. to pay a $8,000 civil penalty after finding Cospolich Refrigerator had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

297

Refrigerator Manufacturers: Order (2013-CE-5341)  

Broader source: Energy.gov [DOE]

DOE ordered Refrigerator Manufacturers, LLC to pay a $8,000 civil penalty after finding Refrigerator Manufacturers had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

298

International Refrigeration: Order (2012-CE-1510)  

Broader source: Energy.gov [DOE]

DOE ordered International Refrigeration Products to pay an $8,000 civil penalty after finding International Refrigeration had failed to certify that certain room air conditioners comply with the applicable energy conservation standard.

299

Previous work conducted in the laboratory demonstrated optimal control of refrigerant flow and airflow for a breadboard CVSHP (Miller 1987a). This previous work was continued in the present study by investigation  

E-Print Network [OSTI]

, and relative humidity on the COP and capacity of the test unit. The refrigerant charge was held constant#12;Previous work conducted in the laboratory demonstrated optimal control of refrigerant flow optimal refrigerant flow and airflow control settings. Previous studies by Tanaka and Yamanaka (1982

Oak Ridge National Laboratory

300

Synthesis of Cascade Refrigeration and Liquefaction Systems  

Science Journals Connector (OSTI)

Synthesis of Cascade Refrigeration and Liquefaction Systems ... Current Status and Perspectives of Liquefied Natural Gas (LNG) Plant Design ...

Francisco J. Barnés; C. Judson King

1974-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Interactive Synthesis of Cascade Refrigeration Systems  

Science Journals Connector (OSTI)

Interactive Synthesis of Cascade Refrigeration Systems ... Current Status and Perspectives of Liquefied Natural Gas (LNG) Plant Design ...

Wai Biu Cheng; Richard S. H. Mah

1980-07-01T23:59:59.000Z

302

Using energy audits to investigate the impacts of common air-conditioning design and installation issues on peak power demand and energy consumption in Austin, Texas  

Science Journals Connector (OSTI)

This study presents an analysis of a unique dataset of 4971 energy audits performed on homes in Austin, Texas in 2009–2010. We quantify the prevalence of typical air-conditioner design and installation issues such as low efficiency, oversizing, duct leakage, and low measured capacity, and estimate the impacts that resolving these issues would have on peak power demand and cooling energy consumption. We estimate that air-conditioner use in single-family residences currently accounts for 17–18% of peak demand in Austin, and we found that improving equipment efficiency alone could save up to 205 MW, or 8%, of peak demand. We estimate that 31% of systems in this study were oversized, leading to up to 41 MW of excess peak demand. Replacing oversized systems with correctly sized higher efficiency units has the potential for further savings of up to 81 MW. We estimate that the mean system could achieve 18% and 20% in cooling energy savings by sealing duct leaks and servicing their air-conditioning units to achieve 100% of nominal capacity, respectively. Although this analysis is limited to the City of Austin, understanding the methods described herein could allow electric utilities in similar climates to make better-informed decisions when considering efficiency improvement programs.

Joshua D. Rhodes; Brent Stephens; Michael E. Webber

2011-01-01T23:59:59.000Z

303

The Super Efficient Refrigerator Program: Case study of a Golden Carrot program  

SciTech Connect (OSTI)

The work in this report was conducted by the Analytic Studies Division (ASD) of the National Renewable Energy Laboratory (NREL) for the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy, Office of Building Technologies. This case study describes the development and implementation of the Super Efficient Refrigerator Program (SERP), which awarded $30 million to the refrigerator manufacturer that developed and commercialized a refrigerator that exceeded 1993 federal efficiency standards by at least 25%. The program was funded by 24 public and private utilities. As the first Golden Carrot program to be implemented in the United States, SERP was studied as an example for future `market-pull` efforts.

Eckert, J B

1995-07-01T23:59:59.000Z

304

Wheel-type magnetic refrigerator  

DOE Patents [OSTI]

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load. 7 figs.

Barclay, J.A.

1983-10-11T23:59:59.000Z

305

Comparative Study Between Air-Cooled and Water-Cooled Condensers of the Air-Conditioning Systems  

E-Print Network [OSTI]

consumptions. The cooling capacities for WC and AC systems were 373 and 278 tons-of- refrigeration, respectively. It was found that for the same cooling production, the peak power demand and the daily energy consumption of the WC system were 45 and 32% less...

Maheshwari, G. P.; Mulla Ali, A. A.

2004-01-01T23:59:59.000Z

306

Investigation and Analysis of Energy Consumption and Cost of Electric Air Conditioning Systems in Civil Buildings in Changsha  

E-Print Network [OSTI]

based on the electric refrigeration. Among the heat sources, the prospect of gas boilers is better. In addition, the air source heat pump depends heavily on whether some crucial issues such as frost can be solved during its application. The water-source...

Xie, D.; Chen, J.; Zhang, G.; Zhang, Q.

2006-01-01T23:59:59.000Z

307

Covered Product Category: Residential Refrigerators  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including residential refrigerators, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

308

" Million Housing Units, Final"  

U.S. Energy Information Administration (EIA) Indexed Site

3 Air Conditioning in U.S. Homes, by Year of Construction, 2009" 3 Air Conditioning in U.S. Homes, by Year of Construction, 2009" " Million Housing Units, Final" ,,"Year of Construction" ,"Total U.S.1 (millions)" ,,"Before 1940","1940 to 1949","1950 to 1959","1960 to 1969","1970 to 1979","1980 to 1989","1990 to 1999","2000 to 2009" "Air Conditioning" "Total Homes",113.6,14.4,5.2,13.5,13.3,18.3,17,16.4,15.6 "Air Conditioning Equipment" "Use Air Conditioning Equipment",94,10.5,4,10.6,10.5,15.1,14.1,14.7,14.4 "Have Air Conditioning Equipment But" "Do Not Use It",4.9,0.9,0.2,0.8,0.6,0.8,0.9,0.3,0.4 "Do Not Have Air Conditioning Equipment",14.7,3,0.9,2.2,2.2,2.4,2,1.3,0.8

309

DOE/AHAM advanced refrigerator technology development project  

SciTech Connect (OSTI)

As part of the effort to improve residential energy efficiency and reduce greenhouse emissions from power plants, several design options were investigated for improving the energy efficiency of a conventionally designed domestic refrigerator-freezer. The program goal was to reduce the energy consumption of a 20-ft{sup 3} (570-L) top-mount refrigerator-freeze to 1.00 kWh/d, a 50% reduction from the 1993 National Appliance Energy Conservation Act (NAECA) standard. The options--such as improved cabinet and door insulation, a high-efficiency compressor, a low-wattage fan, a large counterflow evaporator, and adaptive defrost control--were incorporated into prototype refrigerator-freezer cabinets and refrigeration systems. The refrigerant HFC-134a was used as a replacement for CFC-12. The baseline energy performance of the production refrigerator-freezers, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. The project consisted of three main phases: (1) an evaluation of energy-efficient design options using computer simulation models and experimental testing, (2) design and testing of an initial prototype unit, and (3) energy and economic analyses of a final prototype. The final prototype achieved an energy consumption level of 0.93 kWh/d--an improvement of 45% over the baseline unit and 54% over the 1993 NAECA standard for 20-fg{sup 3} (570-L) units. The manufacturer`s cost for those improvements was estimated at $134; assuming that cost is doubled for the consumer, it would take about 11.4 years to pay for the design changes. Since the payback period was thought to be unfeasible, a second, more cost-effective design was also tested. Its energy consumption level was 1.16 kWh/d, a 42% energy savings, at a manufacturer`s cost increase of $53. Again assuming a 100% markup, the payback for this unit would be 6.6 years.

Vineyard, E.A.; Sand, J.R.; Rice, C.K.; Linkous, R.L.; Hardin, C.V.; Bohman, R.H.

1997-03-01T23:59:59.000Z

310

Energy consumption testing of innovative refrigerator-freezers  

SciTech Connect (OSTI)

The high ambient temperature of the Canadian Standards Association (CSA) and the AHAM/DOE Refrigerator-Freezer Energy Consumption Standards is intended to compensate for the lack of door openings and other heat loads. Recently published results by Meier and Jansky (1993) indicate labeled consumption overpredicting typical field consumption by 15%. In-house field studies on conventional models showed labeled consumption overpredicting by about 22%. The Refrigerator-Freezer Technology Assessment (RFTA) test was developed to more accurately predict field consumption. This test has ambient temperature and humidity, door openings, and condensation control set at levels intended to typify Canadian household conditions. It also assesses consumption at exactly defined compartment rating temperatures. Ten conventional and energy-efficient production models were laboratory tested. The RFTA results were about 30% lower than labeled. Similarly, the four innovative refrigerator-freezer models, when field tested, also had an average of 30% lower consumption than labeled. Thus, the results of the limited testing suggest that the RFTA test may be a more accurate predictor of field use. Further testing with a larger sample is recommended. Experimental results also indicated that some innovative models could save up to 50% of the energy consumption compared with similar conventional units. The technologies that contributed to this performance included dual compressors, more efficient compressors and fan motors, off-state refrigerant control valve, fuzzy logic control, and thicker insulation. The larger savings were on limited production models, for which additional production engineering is required for full marketability.

Wong, M.T.; Howell, B.T.; Jones, W.R. [Ontario Hydro Technologies, Toronto, Ontario (Canada); Long, D.L. [Statistical Solutions, Mississauga, Ontario (Canada)

1995-12-31T23:59:59.000Z

311

Superefficient Refrigerators: Opportunities and Challenges for Efficiency Improvement Globally  

SciTech Connect (OSTI)

As an energy-intensive mainstream product, residential refrigerators present a significant opportunity to reduce electricity consumption through energy efficiency improvements. Refrigerators expend a considerable amount of electricity during normal use, typically consuming between 100 to 1,000 kWh of electricity per annum. This paper presents the results of a technical analysis done for refrigerators in support of the Super-efficient Equipment and Appliance Deployment (SEAD) initiative. Beginning from a base case representative of the average unit sold in India, we analyze efficiency improvement options and their corresponding costs to build a cost-versus-efficiency relationship. We then consider design improvement options that are known to be the most cost effective and that can improve efficiency given current design configurations. We also analyze and present additional super-efficient options, such as vacuum-insulated panels. We estimate the cost of conserved electricity for the various options, allowing flexible program design for market transformation programs toward higher efficiency. We estimate ~;;160TWh/year of energy savings are cost effective in 2030, indicating significant potential for efficiency improvement in refrigerators in SEAD economies and China.

Shah, Nihar; Park, Won Young; Bojda, Nicholas; McNeil, Michael A.

2014-08-01T23:59:59.000Z

312

Control and Diagnostics for Rooftop Units- 2014 BTO Peer Review  

Broader source: Energy.gov [DOE]

Presenter: Jim Braun, Purdue University (The Pennsylvania State University Consortium for Building Energy Innovation) This project aims to develop and validate cost-effective methods for rooftop air conditioning unit (RTU) coordination and diagnostics in small commercial buildings.

313

Fridge of the future: ORNL`s refrigeration R&D  

SciTech Connect (OSTI)

Fears about warming the globe may change the way foods are chilled. Concern about global warming, as expressed in the President`s Climate Change Action Plan of 1993, is the latest motivation for putting future American refrigerators and freezers on a strict energy diet. A current national goal is to design an environmentally sound refrigerator-freezer by 1998 that uses half as much energy as 1993 models. Interest in designing a more energy-efficient refrigerator is not new. It first became a goal almost 20 years ago. In the 1970`s the United States was relying on increasingly unstable supplies of imported oil for fuel, and energy prices began to rise. Utilities balked at building additional power plants because of rising costs and investment risks. As a result, a premium was placed on developing energy-efficient appliances, culminating in the passage of the National Appliance Energy Conservation Act of 1987. In the late 1980`s refrigerator design was again a target of engineers because of the need to change the refrigerant and insulation used. The reason: the Montreal Protocol called for phasing out of substances containing chlorofluorocarbons (CFCs) by the year 2000 because they were thought to be destroying the earth`s stratospheric ozone layer. Ozone shields humans from solar rays that can cause skin cancer and cataracts. Among the CFCs to be phased out are common refrigerants like R-12 and the refrigerator insulation blowing agent R-11.

Krause, C.

1995-12-31T23:59:59.000Z

314

Evaluation of a Local Air Conditioning Duty Cycling Device as a Load Management Tool  

E-Print Network [OSTI]

.25 minutes. This setting allows a maximum reduction of the demand of the condensing unit of 30%. The direct control device is part of a bi-directional power line carrier load management system. It is a three tier system consisting of a central control... lines to the central control computer (CCC). Once a week, the load survey data from the CCC was copied to a tape to be transferred to the Mesquite Data Center for analysis. A heating and cooling load calculation was performed on each house...

Schneider, K.; Thedford, M.

1986-01-01T23:59:59.000Z

315

Using Hydrated Salt Phase Change Materials for Residential Air Conditioning Peak Demand Reduction and Energy Conservation in Coastal and Transitional Climates in the State of California  

E-Print Network [OSTI]

The recent rapid economic and population growth in the State of California have led to a significant increase in air conditioning use, especially in areas of the State with coastal and transitional climates. This fact makes ...

Lee, Kyoung Ok

2013-05-31T23:59:59.000Z

316

Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems  

Science Journals Connector (OSTI)

The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry ( 12 °C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70 % and molds by > 80 %). However, during long periods of high relative humidity (> 80 % R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occured. These microorganisms were mainly smaller than 1.1 ?m therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80 % R. H. (mean of 3 days), e. g. by using preheaters in front of air filters in HVAC-systems.

Martin Möritz; Hans Peters; Bettina Nipko; Hennin Rüden

2001-01-01T23:59:59.000Z

317

Modeling and Control of Aggregated Air Conditioning Loads Under Realistic Conditions  

SciTech Connect (OSTI)

Demand-side control is playing an increasingly important role in smart grid control strategies. Modeling the dynamical behavior of a large population of appliances is especially important to evaluate the effectiveness of various load control strategies. In this paper, a high accuracy aggregated model is first developed for a population of HVAC units. The model efficiently includes statistical information of the population, systematically deals with heterogeneity, and accounts for a second-order effect necessary to accurately capture the transient dynamics in the collective response. Furthermore, the model takes into account the lockout effect of the compressor in order to represent the dynamics of the system under control more accurately. Then, a novel closed loop load control strategy is designed to track a desired demand curve and to ensure a stable and smooth response.

Chang, Chin-Yao; Zhang, Wei; Lian, Jianming; Kalsi, Karanjit

2013-02-24T23:59:59.000Z

318

" Million U.S. Housing Units"  

U.S. Energy Information Administration (EIA) Indexed Site

6 Air Conditioning Characteristics by Type of Housing Unit, 2005" 6 Air Conditioning Characteristics by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Air Conditioning Characteristics",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,72.1,7.6,7.8,16.7,6.9 "Do Not Have Cooling Equipment",17.8,10.9,1.5,1.5,2.8,1.2 "Have Cooling Equipment",93.3,61.2,6.1,6.3,13.9,5.8 "Use Cooling Equipment",91.4,60.3,6,6.1,13.5,5.5 "Have Equipment But Do Not Use it",1.9,1,"Q",0.2,0.4,"Q"

319

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) | Department of  

Broader source: Energy.gov (indexed) [DOE]

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) April 25, 2013 DOE ordered Duracold Refrigeration Manufacturing Company, LLC to pay a $8,000 civil penalty after finding Duracold Refrigeration Manufacturing had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards. The Order adopted a Compromise Agreement, which reflected settlement terms between DOE and Duracold Refrigeration Manufacturing. Duracold Refrigeration Manufacturing: Order (2013-CE-5342) More Documents & Publications Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) North Star Refrigerator: Order (2013-CE-5355) Schott Gemtron: Order (2013-CE-5358

320

CO2 Supermarket Refrigeration Systems for Southeast Asia and the USA  

SciTech Connect (OSTI)

This paper presents a comparative analysis of the annual energy consumption of these refrigeration systems in eighty eight cities from all climate zones in Southeast Asia. Also, the performance of the CO2 refrigeration systems is compared to the baseline R404A multiplex direct expansion (DX) system. Finally, the overall performance of the CO2 refrigeration systems in various climatic conditions in Southeast Asia is compared to that in the United States. For the refrigeration systems investigated, it was found that the Transcritical Booster System with Bypass Compressor (TBS-BC) performs better or equivalent to the R404A multiplex DX system in the northern regions of Southeast Asia (China and Japan). In the southern regions of Southeast Asia (India, Bangladesh, Burma), the R404A multiplex DX system and the Combined Secondary Cascade (CSC) system performs better than the TBS-BC.

Sharma, Vishaldeep [ORNL; Fricke, Brian A [ORNL; Bansal, Pradeep [ORNL

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

LPG recovery from refinery flare by waste heat powered absorption refrigeration  

SciTech Connect (OSTI)

A waste heat powered ammonia Absorption Refrigeration Unit (ARU) has commenced operation at the Colorado Refining Company in Commerce City, Colorado. The ARU provides 85 tons of refrigeration at 30 F to refrigerate the net gas/treat gas stream, thereby recovering 65,000 barrels per year of LPG which formerly was flared or burned as fuel. The ARU is powered by the 290 F waste heat content of the reform reactor effluent. An additional 180 tons of refrigeration is available at the ARU to debottleneck the FCC plant wet gas compressors by cooling their inlet vapor. The ARU is directly integrated into the refinery processes, and uses enhanced, highly compact heat and mass exchange components. The refinery's investment will pay back in less than two years from increased recovery of salable product, and CO{sub 2} emissions are decreased by 10,000 tons per year in the Denver area.

Erickson, D.C.; Kelly, F.

1998-07-01T23:59:59.000Z

322

Quantum-enhanced absorption refrigerators  

E-Print Network [OSTI]

Thermodynamics is a branch of science blessed by an unparalleled combination of generality of scope and formal simplicity. Based on few natural assumptions together with the four laws, it sets the boundaries between possible and impossible in macroscopic aggregates of matter. This triggered groundbreaking achievements in physics, chemistry and engineering over the last two centuries. Close analogues of those fundamental laws are now being established at the level of individual quantum systems, thus placing limits on the operation of quantum-mechanical devices. Here we study quantum absorption refrigerators, which are driven by heat rather than external work. We establish thermodynamic performance bounds for these machines and investigate their quantum origin. We also show how those bounds may be pushed beyond what is classically achievable, by suitably tailoring the environmental fluctuations via quantum reservoir engineering techniques. Such superefficient quantum-enhanced cooling realises a promising step towards the technological exploitation of autonomous quantum refrigerators.

Luis A. Correa; José P. Palao; Daniel Alonso; Gerardo Adesso

2013-08-19T23:59:59.000Z

323

HFC supermarket refrigeration demonstration. Phases 1 and 2  

SciTech Connect (OSTI)

The HFC Supermarket Refrigeration Demonstration tested and evaluated HFC refrigerants in a new Shop `n Save supermarket in Glens Falls, New York. This project included laboratory testing of HFC refrigerants for medium- and low-temperature application, the design of a supermarket refrigeration system to accommodate the new refrigerants, installation, start-up, and field monitoring.

Borhanian, H.; Rafuse, L.

1996-04-01T23:59:59.000Z

324

Energy and economic performance analysis of an open cycle solar desiccant dehumidification air-conditioning system for application in Hong Kong  

Science Journals Connector (OSTI)

In this article, a transient simulation model and the EnergyPlus were used to study the energy performance and economical feasibility for integrating a solar liquid desiccant dehumidification system with a conventional vapor compression air-conditioning system for the weather condition of Hong Kong. The vapor compression system capacity in the solar assisted air-conditioning system can be reduced to 19 kW from original 28 kW of a conventional air-conditioning system as a case study due to the solar desiccant cooling. The economical performance of the solar desiccant dehumidification system is compared with that of the conventional air-conditioning system. The results show that the energy saving potentials due to incorporation of the solar desiccant dehumidification system in a traditional air-conditioning system is significant for the hot wet weather in Hong Kong due to higher COP resulted from higher supply chilled water temperature from chiller plants. The annual operation energy savings for the hybrid system is 6760 kWh and the payback period of the hybrid system is around 7 years. The study shows that the solar assisted air-conditioning is a viable technology for utilizations in subtropical areas.

Yutong Li; Lin Lu; Hongxing Yang

2010-01-01T23:59:59.000Z

325

Suction muffler for refrigeration compressor  

DOE Patents [OSTI]

A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell. 5 figs.

Nelson, R.T.; Middleton, M.G.

1983-01-25T23:59:59.000Z

326

List of Refrigerators Incentives | Open Energy Information  

Open Energy Info (EERE)

Refrigerators Incentives Refrigerators Incentives Jump to: navigation, search The following contains the list of 657 Refrigerators Incentives. CSV (rows 1-500) CSV (rows 501-657) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial Custom Project Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Tribal Government Boilers Central Air conditioners Chillers Custom/Others pending approval Furnaces Heat pumps Heat recovery Lighting Lighting Controls/Sensors Processing and Manufacturing Equipment Refrigerators Yes AEP Ohio - Commercial Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial

327

Natural Refrigerant (R-729) Heat Pump  

Energy Savers [EERE]

Manufactured in the U.S. 2 Problem Statement * Current commercial and industrial heat pumps - Poor coefficient of performance (COP) at low temperatures * HFC refrigerant...

328

Covered Product Category: Commercial Refrigerators and Freezers  

Broader source: Energy.gov [DOE]

The Federal Energy Management Program (FEMP) provides acquisition guidance for commercial refrigerators and freezers, which are covered by the ENERGY STAR program.

329

Design of Industrial Process Refrigeration Systems  

E-Print Network [OSTI]

DESIGN OF INDUSTRIAL PROCESS REfRIGERATION SYSTEMS W.O. WITHERELL AOVENTg Technolog1st Un10n Carb1de Corporat1on South Charleston, West V1rg~n1a ABSTRACT ~hen considering electric driven refrigeration compressors, proper integration... to several canple~ processes that ut iii ze refr igerat ion systems. In IOClSt cases the design of a cOOlllex refrigeration system in isolation (i.e., without considering process integration) generallv results in non-ptilTUll refrigeration levels...

Witherell, W. D.

330

Covered Product Category: Refrigerated Beverage Vending Machines...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

vending machines are equipped with controls or software that put the lighting andor refrigeration systems into a low power state at night, on weekends, or other periods of...

331

IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems Corresponding author: P. Leblay  

E-Print Network [OSTI]

3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems Corresponding author: P on the refrigerant side and louver fins on the air side. The flat tubes are grouped within a header, to use the heat exchangers with round tubes, such as charge reduction and higher heat transfer efficiency. But a reduced

Paris-Sud XI, Université de

332

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

SciTech Connect (OSTI)

Amazon Mechanical Turk was used, for the first time, to collect statistically representative survey data from U.S. households on the presence, number, type and usage of refrigerators, freezers, and various “miscellaneous” refrigeration products (wine/beverage coolers, residential icemakers and non-vapor compression refrigerators and freezers), along with household and demographic information. Such products have been poorly studied to date, with almost no information available about shipments, stocks, capacities, energy use, etc. A total of 9,981 clean survey responses were obtained from five distinct surveys deployed in 2012. General refrigeration product survey responses were weighted to demographics in the U.S. Energy Information Administration’s Residential Energy Consumption Survey 2009 dataset. Miscellaneous refrigeration product survey responses were weighted according to demographics of product ownership found in the general refrigeration product surveys. Model number matching for a portion of miscellaneous refrigeration product responses allowed validation of refrigeration product characteristics, which enabled more accurate estimates of the penetrations of these products in U.S. households. We estimated that there were 12.3±1.0 million wine/beverage coolers, 5.5(–3.5,+3.2) million residential icemakers and 4.4(–2.7,+2.3) million non-vapor compression refrigerators in U.S. households in 2012. (All numerical results are expressed with ranges indicating the 95% confidence interval.) No evidence was found for the existence of non-vapor compression freezers. Moreover, we found that 15% of wine/beverage coolers used vapor compression cooling technology, while 85% used thermoelectric cooling technology, with the vast majority of thermoelectric units having capacities of less than 30 wine bottles (approximately 3.5 cubic feet). No evidence was found for the existence of wine/beverage coolers with absorption cooling technology. Additionally, we estimated that there were 3.6±1.0 million hybrid refrigerator-wine/beverage coolers and 0.9±0.5 million hybrid freezer-wine/beverage coolers in U.S. households. We also obtained estimates of miscellaneous refrigeration product capacities, lifetimes, purchase and installation costs, repair frequencies and costs, and maintenance costs. For wine/beverage coolers, we also obtained information on the penetration of built-in units, AC/DC operating capability, the use of internal lights, and distributions of door opening frequencies. This information is essential to develop detailed estimates of national energy usage and life-cycle costs, and would be helpful in obtaining information on other plug-load appliances. Additional information not highlighted in the main report was presented in Appendices.

Greenblatt, Jeffery B.; Young, Scott J.; Yang, Hung-Chia; Long, Timothy; Beraki, Bereket; Price, Sarah K.; Pratt, Stacy; Willem, Henry; Desroches, Louis-Benoit

2013-11-14T23:59:59.000Z

333

Layer of protection analysis applied to ammonia refrigeration systems  

E-Print Network [OSTI]

Ammonia refrigeration systems are widely used in industry. Demand of these systems is expected to increase due to the advantages of ammonia as refrigerant and because ammonia is considered a green refrigerant. Therefore, it is important to evaluate...

Zuniga, Gerald Alexander

2009-05-15T23:59:59.000Z

334

Comfort by Design: An Introduction to HVAC's Variable Refrigerant Flow (VRF) Technology  

E-Print Network [OSTI]

Comfort by Design An Introduction to HVAC’s Variable Refrigerant Flow (VRF) Technology Keith Reihl kreihl@hvac.mea.com ESL-KT-14-11-13 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 HVAC Market Overview 0% 27% 9% 5% 4... Through Efficiency Conference, Dallas, Texas Nov. 18-20 How LOUD is a traditional HVAC unit? 33 dB(A) Library 50 dB(A) Refrigerator 60 dB(A) Conversation 78 dB(A) Vacuum 25 dB(A) Recording Studio 65-75 dB(A) Residential 3-ton HVAC Unit How Q IET are VRF...

Reihl,K.

2014-01-01T23:59:59.000Z

335

Improvement of the Performance for an Absorption Refrigeration System with Lithium bromide-water as Refrigerant by Increasing Absorption Pressure  

E-Print Network [OSTI]

Because the absorption refrigeration system uses the Lithium bromide- water solution as refrigerant, it is profitable for the environment that human beings are living since the values of ODP and GWP of the refrigerant almost are zero. However...

Xie, G.; Sheng, G.; Li, G.; Pan, S.

2006-01-01T23:59:59.000Z

336

Federal Energy Management Program: Covered Product Category: Refrigerated  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Refrigerated Beverage Vending Machines to someone by E-mail Refrigerated Beverage Vending Machines to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Google Bookmark Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Delicious Rank Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on AddThis.com...

337

DOE Opens Three Investigations into Alleged Refrigerator Efficiency...  

Broader source: Energy.gov (indexed) [DOE]

Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations April 12, 2010 - 7:27pm...

338

Corrosion aspects in indirect systems with secondary refrigerants.  

E-Print Network [OSTI]

?? Aqueous solutions of organic or inorganic salts are used as secondary refrigerants in indirect refrigeration systems to transport and transfer heat. Water is known… (more)

Ignatowicz, Monika

2008-01-01T23:59:59.000Z

339

Working Fluids Low Global Warming Potential Refrigerants | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Center. Life Cycle Climate Performance of supermarket refrigeration.
Credit: Oak Ridge National Lab Life Cycle Climate Performance of supermarket refrigeration....

340

DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy...  

Broader source: Energy.gov (indexed) [DOE]

Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements March 16, 2010 - 4:28pm...

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

2014-04-10 Issuance: Test Procedures for Commercial Refrigeration...  

Broader source: Energy.gov (indexed) [DOE]

0 Issuance: Test Procedures for Commercial Refrigeration Equipment; Final Rule 2014-04-10 Issuance: Test Procedures for Commercial Refrigeration Equipment; Final Rule This document...

342

Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants - 2013 Peer Review Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants - 2013 Peer Review...

343

Working Fluids Low Global Warming Potential Refrigerants - 2013...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Working Fluids Low Global Warming Potential Refrigerants - 2013 Peer Review Working Fluids Low Global Warming Potential Refrigerants - 2013 Peer Review Emerging Technologies...

344

Closed cycle liquid helium refrigerators  

Science Journals Connector (OSTI)

We have developed closed cycle liquid helium refrigerators using a Joule Thomson circuit precooled by commercially available two staged Gifford Mac Mahon cryocoolers. The Joule Thomson counterflow heat exchangers are modular and have been thermo-hydraulically characterized. Fully automatic cool down and operation are achieved by two pneumatically driven by pass and expansion valves. Several apparatus have been built or are under assembly with cooling power ranging from 100 mW up to 5 Watt, for temperature ranging from 2.8 K up to 4.5 K. A trouble free operation with several warm up and cool down cycles has been proven over 7000 hours.

G. Claudet; R. Lagnier; A. Ravex

1992-01-01T23:59:59.000Z

345

Seven-effect absorption refrigeration  

DOE Patents [OSTI]

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit. 1 fig.

DeVault, R.C.; Biermann, W.J.

1989-05-09T23:59:59.000Z

346

Seven-effect absorption refrigeration  

DOE Patents [OSTI]

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit.

DeVault, Robert C. (Knoxville, TN); Biermann, Wendell J. (Fayetteville, NY)

1989-01-01T23:59:59.000Z

347

New York Power Authority/New York City Housing Authority refrigerator replacement program, first program year evaluation. Final report  

SciTech Connect (OSTI)

Acting as an energy services provider, the New York Power Authority (NYPA) has initiated a long-term project through which 20,000 refrigerators per year will be replaced with the most energy-efficient units possible in apartments managed by the New York City Housing Authority (NYCHA). Using bulk purchasing as an incentive to appliance manufacturers to produce energy-efficient refrigerators suitable for use in apartments, replaced in the first year of the program, which ended in December 1996. These units, kWh per year. Savings were determined by field testing and laboratory testing of 220 existing refrigerators and 56 newly-installed units. In the next program year, a 15.0-cubic-foot Maytag refrigerator, newly-designed in response to bulk purchasing incentives, is being installed. The new unit has a label rating of 437 kWh per year, 31 percent better than 1993 energy standards. Old refrigerators removed from apartments are {open_quotes}demanufactured{close_quotes} in an environmentally-appropriate way and both metals and refrigerants are recovered for reuse.

Kinney, L.F.; Lewis, G. [Synertech Systems Corp., Syracuse, NY (United States); Pratt, R.G.; Miller, J. [Pacific Northwest National Lab., Richland, WA (United States)

1997-08-01T23:59:59.000Z

348

Modeling supermarket refrigeration energy use and demand  

SciTech Connect (OSTI)

A computer model has been developed that can predict the performance of supermarket refrigeration equipment to within 3% of field test measurements. The Supermarket Refrigeration Energy Use and Demand Model has been used to simulate currently available refrigerants R-12, R-502 and R-22, and is being further developed to address alternative refrigerants. This paper reports that the model is expected to be important in the design, selection and operation of cost-effective, high-efficiency refrigeration systems. It can profile the operation and performance of different types of compressors, condensors, refrigerants and display cases. It can also simulate the effects of store humidity and temperature on display cases; the efficiency of various floating head pressure setpoints, defrost alternatives and subcooling methods; the efficiency and amount of heat reclaim from refrigeration systems; and the influence of other variables such as store lighting and building design. It can also be used to evaluate operational strategies such as variable-speed drive or cylinder unloading for capacity control. Development of the model began in 1986 as part of a major effort, sponsored by the U.S. electric utility industry, to evaluate energy performance of then conventional single compressor and state-of-the-art multiplex refrigeration systems, and to characterize the contribution of a variety of technology enhancement features on system energy use and demand.

Blatt, M.H.; Khattar, M.K. (Electric Power Research Inst., Palo Alto, CA (US)); Walker, D.H. (Foster Miller Inc., Waltham, MA (US))

1991-07-01T23:59:59.000Z

349

North Star Refrigerator: Order (2013-CE-5355)  

Broader source: Energy.gov [DOE]

DOE ordered North Star Refrigerator Co., Inc. to pay a $8,000 civil penalty after finding North Star Refrigerator had failed to certify that any basic models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

350

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve  

E-Print Network [OSTI]

State Tests(wet coil). . . .26 2. Steady State & Cyclic (dry coil) TESTS 26 CAPACITY 32 1. Steady State Tests(wet coil)... .32 1.1 Subcooling and Superheat Temperatures 34 1.2 Refrigerant Flow Rate. . . .37 1.3 Sensible Heat Ratio 39 2. Steady State... Typical Refrigerant Temperature Probe . . . .14 2.6 The Fully Charged Subcooling Temperature as a Function of Outdoor Temperature 18 3.1 Refrigerant-Side/Air-Side Capacity Comparison 24 3.2 Total Capacity of the Fully Charged Unit. . . .27 3.3 Energy...

Farzad, M.; O'Neal, D. L.

1989-01-01T23:59:59.000Z

351

" Million U.S. Housing Units"  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air-Conditioning Usage Indicators by Number of Household Members, 2005" 7 Air-Conditioning Usage Indicators by Number of Household Members, 2005" " Million U.S. Housing Units" ,,"Number of Households With --" ,"Housing Units (millions)" ,,"1 Member","2 Members","3 Members","4 Members","5 or More Members" "Air-Conditioning Usage Indicators" "Total",111.1,30,34.8,18.4,15.9,12 "Do Not Have Cooling Equipment",17.8,5.4,5.3,2.7,2.5,2 "Have Cooling Equipment",93.3,24.6,29.6,15.7,13.4,10 "Use Cooling Equipment",91.4,24,29.1,15.5,13.2,9.7 "Have Equipment But Do Not Use it",1.9,0.6,0.5,"Q",0.2,0.4 "Type of Air-Conditioning Equipment1, 2" "Central System",65.9,15.3,22.6,10.7,9.9,7.3

352

" Million U.S. Housing Units"  

U.S. Energy Information Administration (EIA) Indexed Site

6 Air Conditioning Characteristics by Number of Household Members, 2005" 6 Air Conditioning Characteristics by Number of Household Members, 2005" " Million U.S. Housing Units" ,,"Number of Households With --" ,"Housing Units (millions)" ,,"1 Member","2 Members","3 Members","4 Members","5 or More Members" "Air Conditioning Characteristics" "Total",111.1,30,34.8,18.4,15.9,12 "Do Not Have Cooling Equipment",17.8,5.4,5.3,2.7,2.5,2 "Have Coolling Equipment",93.3,24.6,29.6,15.7,13.4,10 "Use Cooling Equipment",91.4,24,29.1,15.5,13.2,9.7 "Have Equipment But Do Not Use it",1.9,0.6,0.5,"Q",0.2,0.4 "Air-Conditioning Equipment1, 2 " "Central System",65.9,15.3,22.6,10.7,9.9,7.3

353

Dynamic simulation of a reverse Brayton refrigerator  

SciTech Connect (OSTI)

A test refrigerator based on the modified Reverse Brayton cycle has been developed in the Chinese Academy of Sciences recently. To study the behaviors of this test refrigerator, a dynamic simulation has been carried out. The numerical model comprises the typical components of the test refrigerator: compressor, valves, heat exchangers, expander and heater. This simulator is based on the oriented-object approach and each component is represented by a set of differential and algebraic equations. The control system of the test refrigerator is also simulated, which can be used to optimize the control strategies. This paper describes all the models and shows the simulation results. Comparisons between simulation results and experimental data are also presented. Experimental validation on the test refrigerator gives satisfactory results.

Peng, N.; Xiong, L. Y.; Dong, B.; Liu, L. Q. [State Key Laboratory of Technologies in Space Cryogenic Propellants, Technical Institute of Physics and Chemistry, CAS, Beijing, 100190 (China); Lei, L. L.; Tang, J. C. [State Key Laboratory of Technologies in Space Cryogenic Propellants, Technical Institute of Physics and Chemistry, CAS, Beijing, 100190 China and Graduate University of Chinese Academy of Sciences, Beijing, 100190 (China)

2014-01-29T23:59:59.000Z

354

Oil cooled, hermetic refrigerant compressor  

DOE Patents [OSTI]

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler 18 and is then delivered through the shell to the top of the motor rotor 24 where most of it is flung radially outwardly within the confined space provided by the cap 50 which channels the flow of most of the oil around the top of the stator 26 and then out to a multiplicity of holes 52 to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber 58 to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole 62 also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator 68 from which the suction gas passes by a confined path in pipe 66 to the suction plenum 64 and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum 64.

English, William A. (Murrysville, PA); Young, Robert R. (Murrysville, PA)

1985-01-01T23:59:59.000Z

355

Oil cooled, hermetic refrigerant compressor  

DOE Patents [OSTI]

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler and is then delivered through the shell to the top of the motor rotor where most of it is flung radially outwardly within the confined space provided by the cap which channels the flow of most of the oil around the top of the stator and then out to a multiplicity of holes to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator from which the suction gas passes by a confined path in pipe to the suction plenum and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum. 3 figs.

English, W.A.; Young, R.R.

1985-05-14T23:59:59.000Z

356

Process Systems Engineering Optimal Synthesis of Refrigeration Cycles  

E-Print Network [OSTI]

Process Systems Engineering Optimal Synthesis of Refrigeration Cycles and Selection of Refrigerants, University Park, PA 16802 The optimal synthesis of the refrigeration configuration and the selection of the best refrigerants that satisfy a set of process cooling duties at different temperatures is ad- dressed

Maranas, Costas

357

DOE Publishes Supplemental Proposed Determination for Miscellaneous Residential Refrigeration Products  

Broader source: Energy.gov [DOE]

The Department of Energy has published a supplemental proposed determination regarding miscellaneous residential refrigeration products.

358

Deemed Savings Estimates for Legacy Air Conditioning and WaterHeating Direct Load Control Programs in PJM Region  

SciTech Connect (OSTI)

During 2005 and 2006, the PJM Interconnection (PJM) Load Analysis Subcommittee (LAS) examined ways to reduce the costs and improve the effectiveness of its existing measurement and verification (M&V) protocols for Direct Load Control (DLC) programs. The current M&V protocol requires that a PURPA-compliant Load Research study be conducted every five years for each Load-Serving Entity (LSE). The current M&V protocol is expensive to implement and administer particularly for mature load control programs, some of which are marginally cost-effective. There was growing evidence that some LSEs were mothballing or dropping their DLC programs in lieu of incurring the expense associated with the M&V. This project had several objectives: (1) examine the potential for developing deemed savings estimates acceptable to PJM for legacy air conditioning and water heating DLC programs, and (2) explore the development of a collaborative, regional, consensus-based approach for conducting monitoring and verification of load reductions for emerging load management technologies for customers that do not have interval metering capability.

Goldman, Charles

2007-03-01T23:59:59.000Z

359

Design and Operation of Fan-Coil Units in Using River Water as Chilled Water  

E-Print Network [OSTI]

Based on the case research for China's first central air conditioning system utilizing natural cool river water as chilled water, this paper analyzes the technical design-and-innovation process and operating characteristics of Fan-Coil Units (FCUs...

Jiang, A.; Chen, H.; Ma, W.; Zhu, H.

2006-01-01T23:59:59.000Z

360

Estimation of Hourly Solar Loads on the Surfaces of Moving Refrigerated Tractor Trailers Outfitted with Phase Change Materials (PCMs) for Several Routes across the Continental U.S.  

E-Print Network [OSTI]

The primary objective of this thesis was to calculate solar loads, wind chill temperatures on the surfaces of moving refrigerated tractor trailers outfitted with phase change materials (PCMs) for several routes across the Continental United States...

Varadarajan, Krupasagar

2011-08-31T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Refrigerant charge management in a heat pump water heater  

DOE Patents [OSTI]

Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

Chen, Jie; Hampton, Justin W.

2014-06-24T23:59:59.000Z

362

PhD student in Energy Technology, specifically in Commercial refrigeration systems with CO2 as refrigerant  

E-Print Network [OSTI]

the use of carbon dioxide as refrigerant in supermarket refrigeration systems. The work includes fieldPhD student in Energy Technology, specifically in Commercial refrigeration systems with CO2 a PhD student in Energy Technology, specifically Commercial refrigeration systems with CO2

Kazachkov, Ivan

363

Performance of a two-cycle refrigerator/freezer using HFC refrigerants  

SciTech Connect (OSTI)

A two-cycle 18 ft{sup 3} (0.51 m{sup 3}) refrigerator/freezer was tested utilizing American National Standards Institute/Association of Home Appliance Manufacturers (ANSI/AHAM) standards for energy consumption testing. A 34.9% energy consumption reduction was realized for a 1984 model refrigerator/freezer (1020 kWh original energy use). This paper presents a proven method of reducing the current Department of Energy (DOE) minimum energy-efficiency standards for refrigerator/freezers to the proposed year 2001 standards utilizing existing technology. For a top-mount, frost-free refrigerator/freezer having the above volume, the current DOE minimum energy standard is 770 kWh/year, and the proposed DOE year 2001 standard is 530 kWh/year (a 31% reduction). Therefore, some significant reductions may be obtained by implementing the modifications discussed in this paper into newer refrigerator/freezer models. The paper gives an overview of the modifications implemented by a Danish university on a US refrigerator/freezer and presents experimental performance testing results of the refrigerator/freezer. The modifications will cause the refrigerator/freezer to be more expensive, but the performance enhancements should offset cost. No cost analysis is presented in this paper, but a detailed cost analysis of a two-cycle refrigerator/freezer is contained in a 1993 US Environmental Protection Agency (EPA) report (EPA 1993). The refrigerator/freezer was tested using four refrigerants and compressors. Two compressors and refrigerants were tested in the freezer cycle, and four were tested in the fresh food cycle.

Baskin, E.; Delafield, F.R.

1999-07-01T23:59:59.000Z

364

23.11.2014bo Akademi Univ -Thermal and Flow Engineering Piispankatu 8, 20500 Turku 1/36 7. Air conditioning, cooling towers  

E-Print Network [OSTI]

23.11.2014Ã?bo Akademi Univ - Thermal and Flow Engineering Piispankatu 8, 20500 Turku 1/36 7. Air conditioning, cooling towers Ron Zevenhoven Ã?bo Akademi University Thermal and Flow Engineering Laboratory Engineering Piispankatu 8, 20500 Turku 2/36 7.1 Humid air #12;23.11.2014 Ã?bo Akademi Univ - Thermal and Flow

Zevenhoven, Ron

365

Air Conditioning Cold/Heat Source Analysis of the Inclusion of the Monetary Values of Environmental Damage Based on the LCA Theory  

E-Print Network [OSTI]

of Life Cycle Assessment (LCA) and Willingness - to - pay (WTP). The analysis makes it possible to compare the technical and eco-nomic differences of the air conditioning system based on business economics to a system with greater empha-sis on socio...

Li, Z.; Duanmu, L.; Shu, H.; Zhu, Y.

2006-01-01T23:59:59.000Z

366

Occupant Response to Window Control Signaling Systems  

E-Print Network [OSTI]

Air Conditioning   Fan coil units, variable refrigerant active cooling via fan coil units and radiant panels, system to perimeter fan coil units, and “open”  mode for 

Ackerly, Katherine

2012-01-01T23:59:59.000Z

367

Status of not-in-kind refrigeration technologies for household space conditioning, water heating and food refrigeration  

SciTech Connect (OSTI)

This paper presents a review of the next generation not-in-kind technologies to replace conventional vapor compression refrigeration technology for household applications. Such technologies are sought to provide energy savings or other environmental benefits for space conditioning, water heating and refrigeration for domestic use. These alternative technologies include: thermoacoustic refrigeration, thermoelectric refrigeration, thermotunneling, magnetic refrigeration, Stirling cycle refrigeration, pulse tube refrigeration, Malone cycle refrigeration, absorption refrigeration, adsorption refrigeration, and compressor driven metal hydride heat pumps. Furthermore, heat pump water heating and integrated heat pump systems are also discussed due to their significant energy saving potential for water heating and space conditioning in households. The paper provides a snapshot of the future R&D needs for each of the technologies along with the associated barriers. Both thermoelectric and magnetic technologies look relatively attractive due to recent developments in the materials and prototypes being manufactured.

Bansal, Pradeep [ORNL; Vineyard, Edward Allan [ORNL; Abdelaziz, Omar [ORNL

2012-01-01T23:59:59.000Z

368

Air-Side Energy Use Calculations for Four HVAC Systems: Dual Duct Constant Volume (DDCAV), Dual Duct Variable Volume (DDVAV), Constant Volume with Reheat (CAVRH), Variable Volume with Reheat (VAVRH), Four Pipe Fan Coil Unit (FC), Four Pipe Induction Unit (FI), and Single Zone (SZ) Systems, Revised June 2002  

E-Print Network [OSTI]

(CAVRH), and variable volume with reheat (VAVRH), four pipe fan coil unit (FC), four pipe induction unit (FI), and a single zone air conditioning system (SZ). These calculations are presented in spreadsheets that include a running commentary so...

Haberl, J. S.; Bou-Saada, T. E.; Saman, N. F.

2001-01-01T23:59:59.000Z

369

End-Use Load and Consumer Assessment Program: Analysis of residential refrigerator/freezer performance  

SciTech Connect (OSTI)

The Bonneville Power Administration (Bonneville) is conducting a large end-use data acquisition program in an effort to understand how energy is utilized in buildings with permanent electric space heating equipment in the Pacific Northwest. The initial portion of effort, known as the End-Use Load and Consumer Assessment Program (ELCAP), was conducted for Bonneville by the Pacific Northwest Laboratory (PNL). The collection of detailed end-use data provided an opportunity to analyze the amount of energy consumed by both refrigerators and separate freezers units located in residential buildings. By obtaining this information, the uncertainty of long- term regional end-use forecasting can be improved and potential utility marketing programs for new appliances with a reduced overall energy demand can be identified. It was found that standby loads derived from hourly averages between 4 a.m. and 5 a.m. reflected the minimum consumption needed to maintain interior refrigerator temperatures at a steady-state condition. Next, an average 24-hour consumption that included cooling loads from door openings and cooling food items was also determined. Later, analyses were conducted to develop a model capable of predicting refrigerator standby loads and 24-hour consumption for comparison with national refrigerator label ratings. Data for 140 residential sites with a refrigeration end-use were screened to develop a sample of 119 residences with pure refrigeration for use in this analysis. To identify those refrigerators that were considered to be pure (having no other devices present on the circuit) in terms of their end-use classification, the screening procedure used a statistical clustering technique that was based on standby loads with 24-hour consumption. 5 refs., 18 figs., 4 tabs.

Ross, B.A.

1991-09-01T23:59:59.000Z

370

Small Commercial Refrigeration Incentive | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive < Back Eligibility Agricultural Commercial Industrial Institutional Nonprofit Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Incentives over $5,000 must be pre-approved Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Outside Air Economizers: $1,250 Evaporator Fan Motors: $20 - $100 Evaporator Fan Motor Controls: $550 Door/Frame Heater Controls: $50 per door Case Light Occupancy Controls: $40 LED Refrigerator and Freezer Case Light Fixtures: $6 - $15 per foot Energy Star Ice Machines: $50 - $75 Efficient Compressors: $200 Display Case Strip-Curtain and Continuous Covers: $6 per foot

371

Elastic Metal Alloy Refrigerants: Thermoelastic Cooling  

SciTech Connect (OSTI)

BEETIT Project: UMD is developing an energy-efficient cooling system that eliminates the need for synthetic refrigerants that harm the environment. More than 90% of the cooling and refrigeration systems in the U.S. today use vapor compression systems which rely on liquid to vapor phase transformation of synthetic refrigerants to absorb or release heat. Thermoelastic cooling systems, however, use a solid-state material—an elastic shape memory metal alloy—as a refrigerant and a solid to solid phase transformation to absorb or release heat. UMD is developing and testing shape memory alloys and a cooling device that alternately absorbs or creates heat in much the same way as a vapor compression system, but with significantly less energy and a smaller operational footprint.

None

2010-10-01T23:59:59.000Z

372

Intra-molecular refrigeration in enzymes  

E-Print Network [OSTI]

We present a simple mechanism for intra-molecular refrigeration, where parts of a molecule are actively cooled below the environmental temperature. We discuss the potential role and applications of such a mechanism in biology, in particular in enzymatic reactions.

Hans J. Briegel; Sandu Popescu

2009-12-14T23:59:59.000Z

373

Refrigeration system having standing wave compressor  

DOE Patents [OSTI]

A compression-evaporation refrigeration system, wherein gaseous compression of the refrigerant is provided by a standing wave compressor. The standing wave compressor is modified so as to provide a separate subcooling system for the refrigerant, so that efficiency losses due to flashing are reduced. Subcooling occurs when heat exchange is provided between the refrigerant and a heat pumping surface, which is exposed to the standing acoustic wave within the standing wave compressor. A variable capacity and variable discharge pressure for the standing wave compressor is provided. A control circuit simultaneously varies the capacity and discharge pressure in response to changing operating conditions, thereby maintaining the minimum discharge pressure needed for condensation to occur at any time. Thus, the power consumption of the standing wave compressor is reduced and system efficiency is improved.

Lucas, Timothy S. (Glen Allen, VA)

1992-01-01T23:59:59.000Z

374

Refrigerator Manufacturers: Proposed Penalty (2013-CE-5341)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Refrigerator Manufacturers, LLC failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards.

375

Cospolich Refrigerator: Proposed Penalty (2013-CE-5314)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Cospolich Refrigerator Co, Inc. failed to certify walk-in cooler or freezer components as compliant with the energy conservation standards.

376

Improving Industrial Refrigeration System Efficiency - Actual Applications  

E-Print Network [OSTI]

cycle cooling during winter operation, compressor intercooling, direct refrigeration vs. brine cooling, insulation of cold piping to reduce heat gain, multiple screw compressors for improved part load operation, evaporative condensers for reduced system...

White, T. L.

1980-01-01T23:59:59.000Z

377

Residential Refrigerator Recycling Ninth Year Retention Study  

E-Print Network [OSTI]

Residential Refrigerator Recycling Ninth Year Retention Study Study ID Nos. 546B, 563 Prepared RECYCLING PROGRAMS Study ID Nos. 546B and 563 Prepared for Southern California Edison Rosemead, California

378

Energy use of US residential refrigerators and freezers: function derivation based on household and climate characteristics  

E-Print Network [OSTI]

residential refrigerators and freezers: function derivationsecond most-used) refrigerators, and freezers, and residualfor more efficient refrigerators and freezers, as well as

Greenblatt, Jeffery

2013-01-01T23:59:59.000Z

379

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network [OSTI]

vapor compression refrigerators and freezers), along withthe number of refrigerators and freezers in a home alongcompression refrigerators and freezers) in U.S. households.

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

380

Working Fluids Low Global Warming Potential Refrigerants  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Working Fluids Low GWP Working Fluids Low GWP Refrigerants - CRADA Ed Vineyard Oak Ridge National Laboratory vineyardea@ornl.gov (865) 574-0576 3 April 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: - High GWP refrigerants increase CO 2 equivalent emissions for HVAC&R equipment - Low GWP alternatives may increase energy consumption, introduce safety risks, require significant modifications to equipment, and have higher costs

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Working Fluids Low Global Warming Potential Refrigerants  

Broader source: Energy.gov (indexed) [DOE]

Working Fluids Low GWP Working Fluids Low GWP Refrigerants - CRADA Ed Vineyard Oak Ridge National Laboratory vineyardea@ornl.gov (865) 574-0576 3 April 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: - High GWP refrigerants increase CO 2 equivalent emissions for HVAC&R equipment - Low GWP alternatives may increase energy consumption, introduce safety risks, require significant modifications to equipment, and have higher costs

382

Combined cold compressor/ejector helium refrigerator  

DOE Patents [OSTI]

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, Donald P. (Southold, NY)

1985-01-01T23:59:59.000Z

383

ARI delegation to Japan on Alternative Refrigerants  

SciTech Connect (OSTI)

Researchers from ARI member companies spoke at the International Conference on Alternative Refrigerants in Tokyo and visited several Japanese organizations for the purpose of exchanging information on alternative refrigerants. The specific purpose of the meetings was to review the methods being utilized to screen alternatives to CFCs and HCFCs: materials compatibility screening methods, lubricant testing techniques, as well as flammability studies. A list of papers presented at the conference is included.

Not Available

1993-02-01T23:59:59.000Z

384

Combined cold compressor/ejector helium refrigerator  

DOE Patents [OSTI]

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, D.P.

1984-06-05T23:59:59.000Z

385

ISSUANCE 2014-12-23: Energy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards and Test Procedures for Commercial Heating, Air-Conditioning, and Water-Heating Equipment, Notice of Proposed Rulemaking  

Broader source: Energy.gov [DOE]

Energy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards and Test Procedures for Commercial Heating, Air-Conditioning, and Water-Heating Equipment, Notice of Proposed Rulemaking

386

Energy Impact of Residential Ventilation Norms in the UnitedStates  

SciTech Connect (OSTI)

The first and only national norm for residential ventilation in the United States is Standard 62.2-2004 published by the American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE). This standard does not by itself have the force of regulation, but is being considered for adoption by various jurisdictions within the U.S. as well as by various voluntary programs. The adoption of 62.2 would require mechanical ventilation systems to be installed in virtually all new homes, but allows for a wide variety of design solutions. These solutions, however, may have a different energy costs and non-energy benefits. This report uses a detailed simulation model to evaluate the energy impacts of currently popular and proposed mechanical ventilation approaches that are 62.2 compliant for a variety of climates. These results separate the energy needed to ventilate from the energy needed to condition the ventilation air, from the energy needed to distribute and/or temper the ventilation air. The results show that exhaust systems are generally the most energy efficient method of meeting the proposed requirements. Balanced and supply systems have more ventilation resulting in greater energy and their associated distribution energy use can be significant.

Sherman, Max H.; Walker, Iain S.

2007-02-01T23:59:59.000Z

387

Evaluation of design options for improving the energy efficiency of an environmentally safe domestic refrigerator-freezer  

SciTech Connect (OSTI)

In order to reduce greenhouse emissions from power plants and respond to regulatory actions arising from the National Appliance Energy Conservation Act (NAECA), several design options were investigated for improving the energy efficiency of a conventionally designed, domestic refrigerator-freezer. The options, such as improved cabinet insulation and high-efficiency compressor and fans, were incorporated into a prototype refrigerator-freezer cabinet and refrigeration system to produce a unit that is superior from an environmental viewpoint due to its lower energy consumption and the use of refrigerant HFC-134a as a replacement for CFC-12. Baseline energy performance of the original 1993 production refrigerator-freezer, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. A detailed refrigerator system computer model was used to evaluate the energy savings for several design modifications that, collectively, could achieve a targeted energy consumption of 1.00 kWh/d for a 20 ft{sup 3} (570 l) top-mount, automatic-defrost, refrigerator-freezer. The energy consumption goal represents a 50% reduction in the 1993 NAECA standard for units of this size. Following the modeling simulation, laboratory prototypes were fabricated and tested to experimentally verify the analytical results and aid in improving the model in those areas where discrepancies occurred. While the 1.00 kWh/d goal was not achieved with the modifications, a substantial energy efficiency improvement of 22% (1.41 kWh/d) was demonstrated using near-term technologies. It is noted that each improvement exacts a penalty in terms of increased cost or system complexity/reliability. Further work on this project will analyze cost-effectiveness of the design changes and investigate alternative, more-elaborate, refrigeration system changes to further reduce energy consumption.

Vineyard, E.A.; Sand, J.R. [Oak Ridge National Lab., TN (United States); Bohman, R.H.

1995-03-01T23:59:59.000Z

388

An Exploration of Innovation and Energy Efficiency in an Appliance Industry  

E-Print Network [OSTI]

clothes washers; refrigerators and freezers; dishwashers;and tubes, household refrigerators and freezers, householdhousehold refrigerators and freezers, air conditioning (room

Taylor, Margaret

2013-01-01T23:59:59.000Z

389

Application of Best Industry Practices to the Design of Commercial Refrigerators  

SciTech Connect (OSTI)

The substantial efficiency improvements which have been realized in residential refrigerators over the last twenty years due to implementation of the National Appliance Energy Conservation Act and changing consumer reactions to energy savings give an indication of the potential for improvement in the commercial sector, where few such efficiency improvements have been made to date. The purchase decision for commercial refrigerators is still focused primarily on first cost and product performance issues such as maximizing storage capacity, quick pulldown, durability, and reliability. The project applied techniques used extensively to reduce energy use in residential refrigeration to a commercial reach-in refrigerator. The results will also be applicable to other commercial refrigeration equipment, such as refrigerated vending machines, reach-in freezers, beverage merchandisers, etc. The project described in this paper was a collaboration involving the Appliance and Building Technology Sector of TIAX, the Delfield Company, and the U. S. Department of Energy's Office of Building Technologies. Funding was provided by DOE through Cooperative Agreement No. DE-FC26-00NT41000. The program plan and schedule were structured to assure successful integration of the TIAX work on development of efficient design concepts into Delfield's simultaneous development of the Vantage product line. The energy-saving design options evaluated as part of the development included brushless DC and PSC fan motors, high-efficiency compressors, variable-speed compressor technology, cabinet thermal improvement (particularly in the face frame area), increased insulation thickness, a trap for the condensate line, improved insulation, reduced-wattage antisweat heaters, non-electric antisweat heating, off-cycle defrost termination, rifled heat exchanger tubing, and system optimization (selection of heat exchangers, fans, and subcooling, superheat, and suction temperatures for efficient operation). The project started with a thorough evaluation of the baseline Delfield Model 6051 two-door reach-in refrigerator. Performance testing was done to establish a performance baseline which, to meet end-users requirements, would have to be met or exceeded by the high-efficiency refrigerator design. Energy testing was done to establish the baseline energy use. Diagnostic testing such as reverse heat leak testing and insulation conductivity testing was done to evaluate factors contributing to the cabinet load and energy use. Modeling was done to assess the energy savings potential of the energy saving design options. Discussion with vendors and cost modeling was done to assess the manufacturing cost impact of the options. Based on this work, the following group of design options was selected for incorporation in the final refrigerator design: (1) Brushless DC evaporator fans; (2) Improved face frame design; (3) Reduced antisweat heater wattage; (4) Condensate line trap; and (5) Optimized refrigeration system. There was no net cost premium associated with these design changes, leading to a high-efficiency design requiring no payback of any initial additional investment. Delfield incorporated these design options in the Vantage line design and built a first prototype, which was tested at TIAX. Additional design changes were implemented in the transition to manufacturing, based in part on results of initial prototype testing, and a pilot production unit was sent to TIAX for final testing. The energy use of the pilot production unit was 68% less than that of the baseline refrigerator when tested according to the ASHRAE 117 Energy Test Standard. The energy test results for the baseline refrigerator and the two new-design units is shown in Figure ES-1 below. The resulting energy consumption is well below Energy Star and proposed Canadian and California standards levels. Delfield has successfully transitioned the design to production and is manufacturing all configurations of the energy efficient reach-ins at a rate greater than 7,000 per year, with production quantities projec

None

2002-06-30T23:59:59.000Z

390

Advanced Underground Gas Storage Concepts Refrigerated-Mined Cavern Storage  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

UNDERGROUND GAS STORAGE CONCEPTS UNDERGROUND GAS STORAGE CONCEPTS REFRIGERATED-MINED CAVERN STORAGE FINAL REPORT DOE CONTRACT NUMBER DE-AC26-97FT34349 SUBMITTED BY: PB-KBB INC. 11757 KATY FREEWAY, SUITE 600 HOUSTON, TX 77079 SEPTEMBER 1998 Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily

391

A cryogenic axial-centrifugal compressor for superfluid helium refrigeration  

E-Print Network [OSTI]

CERN's new project, the Large Hadron Collider (LHC), will use superfluid helium as coolant for its high-field superconducting magnets and therefore require large capacity refrigeration at 1.8 K. This may only be achieved by subatmospheric compression of gaseous helium at cryogenic temperature. To stimulate development of this technology, CERN has procured from industry prototype Cold Compressor Units (CCU). This unit is based on a cryogenic axial-centrifugal compressor, running on ceramic ball bearings and driven by a variable-frequency electrical motor operating under low-pressure helium at ambient temperature. The machine has been commissioned and is now in operation. After describing basic constructional features of the compressor, we report on measured performance.

Decker, L; Schustr, P; Vins, M; Brunovsky, I; Lebrun, P; Tavian, L

1997-01-01T23:59:59.000Z

392

Untitled  

U.S. Energy Information Administration (EIA) Indexed Site

Air-Conditioning: Air-conditioning is one of the five end-use categories in Air-Conditioning: Air-conditioning is one of the five end-use categories in this report. It is defined as cooling and dehumidification of the air in a building by a refrigeration unit driven by electricity or gas. This definition excludes fans, blowers, or evaporative cooling systems ("swamp coolers") that are not connected to a refrigeration unit. Air-conditioning units that are not currently in working condition or are not used are still included in the RECS if they are in place in the housing unit. If the household did not use its air-conditioning equipment during the summer of 1993, no consumption and expenditures are imputed for air-conditioning. Apartments: A housing unit in a building with multiple units--a structure that is divided into living quarters for more than one family or household

393

DOE Closes Investigation of Arcelik's Blomberg Refrigerator | Department of  

Broader source: Energy.gov (indexed) [DOE]

Arcelik's Blomberg Refrigerator Arcelik's Blomberg Refrigerator DOE Closes Investigation of Arcelik's Blomberg Refrigerator September 1, 2010 - 4:37pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Arcelik's Blomberg refrigerator-freezer model # BRFB1450. The Department opened this investigation based on a complaint. DOE subpoenaed information from Arcelik, reviewed Arcelik's response, and performed its own testing of this model. Based on our investigation and test results, DOE has determined this model to be compliant with federal energy conservation standards. Notice of Compliance Determination Addthis Related Articles DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Closes Investigation of Whirlpool's Maytag Refrigerator

394

High Efficiency Low Emission Supermarket Refrigeration Research Project |  

Broader source: Energy.gov (indexed) [DOE]

High Efficiency Low Emission Supermarket High Efficiency Low Emission Supermarket Refrigeration Research Project High Efficiency Low Emission Supermarket Refrigeration Research Project The U.S. Department of Energy (DOE) is currently conducting research into high efficiency, low emission supermarket refrigeration technologies. Project Description The project involves the development of a supermarket refrigeration system that can reduce greenhouse gas emissions and energy consumption when compared to existing systems. The challenge is to design a system that is capable of achieving low refrigerant leak rates while significantly reducing both the energy consumption and the refrigerant charge size. Project Partners Research is being undertaken between DOE and Oak Ridge National Laboratory. Project Goals

395

" Million Housing Units, Final"  

U.S. Energy Information Administration (EIA) Indexed Site

0 Air Conditioning in Homes in South Region, Divisions, and States, 2009" 0 Air Conditioning in Homes in South Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"South Census Region" ,,,"South Atlantic Census Division",,,,,,"East South Central Census Division",,,"West South Central Census Division" ,,,,,,,,,"Total East South Central",,,"Total West South Central" ,"Total U.S.1 (millions)",,"Total South Atlantic" ,,"Total South",,,,,"DC, DE, MD, WV",,,,"AL, KY, MS",,,"AR, LA, OK" "Air Conditioning",,,,"VA","GA","FL",,"NC, SC",,"TN",,,"TX" "Total Homes",113.6,42.1,22.2,3,3.5,7,3.4,5.4,7.1,2.4,4.6,12.8,8.5,4.2

396

Energy Efficiency Evaluation of Refrigeration Technologies in Combined Cooling, Heating and Power Systems  

E-Print Network [OSTI]

With development of absorption refrigeration technology, the cooling requirement can be met using various optional refrigeration technologies in a CCHP system, including compression refrigeration, steam double-effect absorption refrigeration, steam...

Zuo, Z.; Hu, W.

2006-01-01T23:59:59.000Z

397

Field test of a high-efficiency, automatic-defrost refrigerator-freezer  

SciTech Connect (OSTI)

Following the successful design, development, and demonstration of a high efficiency refrigerator-freezer prototype, work was done to design and manufacture pre-production units for home usage tests. The purpose of the field test and the associated market evaluation is to confirm the energy saving potential of the high-efficiency design, identify possible design deficiencies or service difficulties, and assess the consumer appeal of the new unit. The first five months of field test data have shown an average 57% decrease in energy consumption when compared to a baseline unit of convention design. This energy savings is larger than predicted by the standard DOE test procedure. No serious design or service problems have been encountered. Consumers have not been adversely affected by the larger cabinet and thicker doors, and responded favorably in an actual retail sales test to initially spending more for an energy-saving refrigerator that will reduce electric usage.

Topping, R.F.; Vineyard, E.A.

1982-01-01T23:59:59.000Z

398

Fridge of the future: Designing a one-kilowatt-hour/day domestic refrigerator-freezer  

SciTech Connect (OSTI)

An industry/government Cooperative Research and Development Agreement (CRADA) was established to evaluate and test design concepts for a domestic refrigerator-freezer unit that represents approximately 60% of the US market. The goal of the CRADA was to demonstrate advanced technologies which reduce, by 50 percent, the 1993 NAECA standard energy consumption for a 20 ft{sup 3} (570 I) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translated to an energy consumption of 1.003 kWh/d. The general objective of the research was to facilitate the introduction of cost-efficient technologies by demonstrating design changes that can be effectively incorporated into new products. A 1996 model refrigerator-freezer was selected as the baseline unit for testing. Since the unit was required to meet the 1993 NAECA standards, the energy consumption was quite low (1.676 kWh/d), thus making further reductions in energy consumption very challenging. Among the energy saving features incorporated into the original design of the baseline unit were a low-wattage evaporator fan, increased insulation thicknesses, and liquid line flange heaters.

Vineyard, E.A.; Sand, J.R.

1998-03-01T23:59:59.000Z

399

Engineering computer models for refrigerators, freezers, furnaces, water heaters, room and central air conditioners  

SciTech Connect (OSTI)

This User's Guide provides the necessary information for understanding and using a computer model developed for the US Department of Energy which predicts the performance (energy consumption) of household refrigerators, refrigerator-freezers, and freezers. The model is capable of simulating various cabinet configurations (top-mount, bottom-mount, side-by-side, single-door) and refrigeration unit combinations (back-mounted static condenser with single forced convection evaporator, hot wall condenser with cooled wall panels, etc.). The program is comprised of two main subroutines: a cabinet heat-load submodel and a refrigeration unit submodel; they can be used separately for preliminary design analysis or together for performance evaluations. A technical description of the model and information on how to structure input parameters are provided. The user is provided with specific guidance for running the model on a computer. Specific instructions are given in the Appendices for changing and running the model using the operating language compatible with the DOE computer terminal system. Other users will have to modify the procedures in these sections as necessary for different computers.

Not Available

1982-11-01T23:59:59.000Z

400

Energy consumption and optimization of internally cooled/heated liquid desiccant air-conditioning system: A case study in Hong Kong  

Science Journals Connector (OSTI)

Abstract LDAC (liquid desiccant air-conditioning system) is promising for reducing the energy consumption, and improving the indoor air quality. In this paper, the operation performance of LDAC with internally cooled/heated dehumidifier/regenerator was simulated and optimized. The cooling tower and solar collectors were employed as the cooling/heating source. Four nested iteration loops were developed and solved for system modeling. A typical commercial building in Hong Kong was selected as a case study, which air-conditioning load was obtained by Energy-plus. Results show that with the increase of solar collector area, the electricity consumption of AC (air-conditioning systems) system reduced by 11–35% in original system, but only a part of dehumidification demand was handled with liquid desiccant ventilation, which led to a low chiller COP (coefficient of performance). By adding a cooling coil for the solution entering dehumidifier, the electricity saving effectively increased to 22–47%, while the heat demand for regeneration also increased by 17%. So, a heat exchanger between water leaving regenerator and solution leaving dehumidifier was introduced. With the lower thermal requirement (reduced by 20%) and higher solar fraction (increased from 30 to 40%), the saving further increased to 29–49%, and the required collector area obviously reduced by 50–60% for the similar energy saving purpose.

Ronghui Qi; Lin Lu

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Energy Consumption of Refrigerators in Ghana - Outcomes of Household  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Consumption of Refrigerators in Ghana - Outcomes of Household Energy Consumption of Refrigerators in Ghana - Outcomes of Household Surveys Speaker(s): Essel Ben Hagan Date: July 12, 2007 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Robert Van Buskirk Galen Barbose As part of activities to develop refrigerator efficiency standards regulations in Ghana, a national survey on the energy consumption of refrigerators and refrigerator-freezers has been conducted. The survey covered 1000 households in urban, peri-urban and rural communities in various parts of the country. The survey found that, on average, refrigerators and refrigerator-freezers in Ghana use almost three times what is allowed by minimum efficiency standards in the U.S., and a few refrigerators had energy use at levels almost ten times the U.S.

402

Loveland Water and Power - Refrigerator Recycling Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Refrigerator Recycling Program Refrigerator Recycling Program Loveland Water and Power - Refrigerator Recycling Program < Back Eligibility Residential Savings Category Appliances & Electronics Maximum Rebate Limit one rebate per account per year Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Refrigerator and Freezer Recycling: $35 Loveland Water and Power is providing an incentive for its customers to recycle their old refrigerators. Interested customers can call the utility to arrange a time to pick up the old refrigerator. The old refrigerator should be brought outside but remain plugged in so the utility can make it is in working condition. the utility will then take the refrigerator to a recycling facility and issue a $35 bill credit. Other Information

403

Refrigerator Standards Save Consumers $ Billions | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Refrigerator Standards Save Consumers $ Billions Refrigerator Standards Save Consumers $ Billions Refrigerator Standards Save Consumers $ Billions March 5, 2013 - 10:35am Addthis Refrigerator Standards Refrigerator Standards Refrigerator technology has come a long way since Dr. John Gorrie (1803 - 1855), a forward-looking inventor, was granted U. S. Patent #8080 for mechanical refrigeration in 1851. In those days, ice was expensive, if it was even available: Blocks of natural ice were carved from frozen lakes and rivers and stored in special warehouses under layers of sawdust for insulation. By the 1890s, pollution and sewage dumping caused by population growth compromised sources of pure, natural ice, threatening the brewing, meat-packing, and dairy industries. As these and other industries sought better solutions, modern refrigeration technology started to evolve.

404

Optimal Design Refrigeration System for a Mucilage Glue Fiber Factory  

E-Print Network [OSTI]

In a mucilage glue fiber factory, the design of the refrigeration system takes into account the characteristics of mucilage glue fiber production and fully uses the refrigeration compressor heat to economize energy and reduce the production cost...

Tan, C.; Liu, J.; Tang, F.; Liu, Y.

2006-01-01T23:59:59.000Z

405

VEE-0079- In the Matter of Diversified Refrigeration, Inc.  

Broader source: Energy.gov [DOE]

Diversified Refrigeration, Inc. (DRI) requests a six-month exception from the 2001 energy appliance efficiency standards for built-in refrigerators that become effective July 1, 2001. As explained...

406

Fully portable, highly flexible dilution refrigerator systems for neutron scattering  

E-Print Network [OSTI]

775 Fully portable, highly flexible dilution refrigerator systems for neutron scattering P. A systems developed specifically for neutron scattering environ- ments. The refrigerators are completely relatively recently however, the lowest temperatures available in almost all neutron scattering laboratories

Boyer, Edmond

407

Energy Savings from Floating Head Pressure in Ammonia Refrigeration Systems  

E-Print Network [OSTI]

This paper presents case studies of two moderately sized ammonia refrigeration systems retrofitted for floating head pressure control. It also presents a parametric analysis to assist in selecting appropriate pressures in an ammonia refrigeration...

Barrer, P. J.; Jones, S. M.

408

DOE Resolves Avanti Refrigerator and Freezer Civil Penalty Case  

Broader source: Energy.gov [DOE]

Today, the Department of Energy announced that it has resolved the civil penalty action against Mackle Company for its failure to certify that refrigerators and refrigerator-freezers sold under the...

409

International Refrigeration: Proposed Penalty (2012-CE-1510)  

Broader source: Energy.gov (indexed) [DOE]

International Refrigeration Products International Refrigeration Products (room air conditioners) ) ) ) ) ) Case Number: 2012-CE-1510 NOTICE OF PROPOSED CIVIL PENALTY Date issued: July 9, 2012 Number of alleged violations: 5475 (365 days, 15 models) Maximum possible assessment: $1,095,000 Proposed civil penalty: $109,500 The U.S. Department of Energy ("DOE") Office of the General Counsel, Office of Enforcement, alleges that International Refrigeration Products ("IRP") has violated cettain provisions of the Energy Policy and Conservation Act, 42 U.S.C. § 6291 et seq. ("the Act"), and 10 C.P.R. § 429.12. Specifically, DOE alleges: 1. IRP has manufactured 1 a variety of Sea Breeze brand room air conditioners, including basic models WA46YR, WA48YRX, WA410YRX, WA412YRX, WH418ZRX,

410

Of Refrigerators & Regulations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Of Refrigerators & Regulations Of Refrigerators & Regulations Of Refrigerators & Regulations February 8, 2011 - 9:29am Addthis Jesse Lee White House Director of Online Affairs Editor's Note: This entry has been cross-posted from The White House Blog. For those interested in the President's remarks to the U.S. Chamber of Commerce and his views on the shared responsibilities of government and business to the American people, our post earlier will give a suitable overview. For those interested in the details of the President's Executive Order on reviewing regulations and their impacts on the economy, Cass Sunstein's post this morning will also be of value. But the President also took a moment during his speech to put the debate over regulation in a different perspective, and to break through the false dichotomy so often

411

Optimal performance of endoreversible quantum refrigerators  

E-Print Network [OSTI]

The derivation of general performance benchmarks is important in the design of highly optimized heat engines and refrigerators. To obtain them, one may model phenomenologically the leading sources of irreversibility ending up with results which are model-independent, but limited in scope. Alternatively, one can take a simple physical system realizing a thermodynamic cycle and assess its optimal operation from a complete microscopic description. We follow this approach in order to derive the coefficient of performance at maximum cooling rate for \\textit{any} endoreversible quantum refrigerator. At striking variance with the \\textit{universality} of the optimal efficiency of heat engines, we find that the cooling performance at maximum power is crucially determined by the details of the specific system-bath interaction mechanism. A closed analytical benchmark is found for endoreversible refrigerators weakly coupled to unstructured bosonic heat baths: an ubiquitous case study in quantum thermodynamics.

Luis A. Correa; José P. Palao; Gerardo Adesso; Daniel Alonso

2014-11-24T23:59:59.000Z

412

Performance prediction of refrigerant-DMF solutions in a single-stage solar-powered absorption refrigeration system at low generating temperatures  

SciTech Connect (OSTI)

A theoretical analysis of the coefficient of performance was undertaken to examine the efficiency characteristics of R22 + DMF, R134a + DMF, R32 + DMF as working fluids, respectively, for a single-stage and intermittent absorption refrigerator which allows the use of heat pipe evacuated tubular collectors. The modeling and simulation of the performance considers both solar collector system and the absorption cooling system. The typical meteorological year file containing the weather parameters for Hangzhou is used to simulate the system. The results show that the system is in phase with the weather. In order to increase the reliability of the system, a hot water storage tank is essential. The optimum ratio of storage tank per solar collector area for Hangzhou's climate for a 1.0 kW system is 0.035-0.043L. Considering the relative low pressure and the high coefficient of performance, R134a + DMF mixture presents interesting properties for its application in solar absorption cycles at moderate condensing and absorbing temperatures when the evaporating temperatures in the range from 278 K to 288 K which are highly useful for food preservation and for air-conditioning in rural areas. (author)

He, L.J. [Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027 (China); Institute of Environment and Energy, Inner Mongolia University of Science and Technology, Baotou 014010 (China); Tang, L.M.; Chen, G.M. [Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027 (China)

2009-11-15T23:59:59.000Z

413

ENVIRONMENTAL ASSESSMENT FOR THE PROPOSED ENERGY CONSERVATION STANDARD FOR REFRIGERATORS, REFRIGERATOR-  

Broader source: Energy.gov (indexed) [DOE]

ASSESSMENT FOR THE PROPOSED ENERGY ASSESSMENT FOR THE PROPOSED ENERGY CONSERVATION STANDARD FOR REFRIGERATORS, REFRIGERATOR- , AND FREEZERS - 1. INTRODUCTION AND NEED FOR PROPOSED ACTION ental Assessment (EA) on the candidate energy conservation stand licy Act. of 1969 (NEPA), regulations of the Council on Environmentd Qu refrigerators, re€iigerator-freezers, and freezers was prepared pursuant to the National ' ederal Regulations, Parts 1500 through. 1508. The proposed energy conservation standard (Level 1) and the alternative standards are being reviewed in an energy- efficiency standards rulemaking that the Department has undertaken pursuant to the Energy Policy and Conservation Act, as amended by the National Energy Conservation Policy Act and the National Appliance Energy Consehation Act

414

Retrofitting Doors on Open Refrigerated Cases  

Broader source: Energy.gov (indexed) [DOE]

Retrofitting Doors on Open Retrofitting Doors on Open Refrigerated Cases William Goetzler Navigant Consulting, Inc. wgoetzler@navigant.com (781) 270-8351 April 4, 2013 BBA Refrigeration Project Team Images courtesy of REMIS AMERICA, LLC. 2 | Building Technologies Office eere.energy.gov Technology Overview Image from Investigation of Energy- Efficient Supermarket Display Cases. 2004, Oak Ridge National Laboratory. Background and Motivation * Adding doors to open cases (retrofits) greatly reduces cold air loss - 50-80% load reduction - Load reduction = system energy savings

415

Development of a prototype optical refrigerator  

SciTech Connect (OSTI)

This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors have carried out a range of tasks directed toward the construction and testing of a proof-of-principle optical refrigerator prototype. They procured and tested new cooling elements that are at the heart of an optical refrigerator. The cooling element absorbs pump radiation and then fluoresces with nearly unity quantum efficiency. They constructed and tested a cooling chamber with low thermal emissivity walls that reduces the parasitic heating.

Epstein, R.I.; Edwards, B.C.; Sigel, G.H.

1998-01-01T23:59:59.000Z

416

Phase boundary detection for dilution refrigerators  

SciTech Connect (OSTI)

We describe a device to conveniently measure the positions of the phase boundaries in a dilution refrigerator. We show how a simple modification of a standard capacitive level gauge (segmentation of one of the electrodes) permits a direct calibration of the capacitance versus phase boundary position. We compare this direct calibration with the indirect procedure that must be adopted for a conventional capacitive level gauge. The device facilitates the correct adjustment of the {sup 3}He/{sup 4}He fraction in the dilution refrigerator.

Haar, E. ter; Martin, R.V. [DFMT, Instituto de Fisica, Universidade de Sao Paulo, C.P. 66.318, 05315-970 Sao Paulo, SP (Brazil)

2004-09-01T23:59:59.000Z

417

Helium refrigeration considerations for cryomodule design  

SciTech Connect (OSTI)

Many of the present day accelerators are based on superconducting radio frequency (SRF) cavities, packaged in cryo-modules (CM), which depend on helium refrigeration at sub-atmospheric pressures, nominally 2 K. These specialized helium refrigeration systems are quite cost intensive to produce and operate. Particularly as there is typically no work extraction below the 4.5-K supply, it is important that the exergy loss between this temperature level and the CM load temperature(s) be minimized by the process configuration choices. This paper will present, compare and discuss several possible helium distribution process arrangements to support the CM loads.

Ganni, V.; Knudsen, P. [Thomas Jefferson National Accelerator Facility (JLab), Newport News, VA 23606 (United States)

2014-01-29T23:59:59.000Z

418

Pipeline gas pressure reduction with refrigeration generation  

SciTech Connect (OSTI)

The high pressure of pipeline gas is reduced to the low pressure of a distribution system with simultaneous generation of refrigeration by passing the gas through two successive centrifugal compressors driven by two turbo-expanders in which the compressed gas is expanded to successively lower pressures. Refrigeration is recovered from the gas as it leaves each turbo-expander. Methanol is injected into the pipeline gas before it is expanded to prevent ice formation. Aqueous methanol condensate separated from the expanded gas is distilled for the recovery and reuse of methanol.

Markbreiter, S. J.; Schorr, H. P.

1985-06-11T23:59:59.000Z

419

Reducing the Carbon Footprint of Commercial Refrigeration Systems Using Life Cycle Climate Performance Analysis: From System Design to Refrigerant Options  

SciTech Connect (OSTI)

In this paper, Life Cycle Climate Performance (LCCP) analysis is used to estimate lifetime direct and indirect carbon dioxide equivalent gas emissions of various refrigerant options and commercial refrigeration system designs, including the multiplex DX system with various hydrofluorocarbon (HFC) refrigerants, the HFC/R744 cascade system incorporating a medium-temperature R744 secondary loop, and the transcritical R744 booster system. The results of the LCCP analysis are presented, including the direct and indirect carbon dioxide equivalent emissions for each refrigeration system and refrigerant option. Based on the results of the LCCP analysis, recommendations are given for the selection of low GWP replacement refrigerants for use in existing commercial refrigeration systems, as well as for the selection of commercial refrigeration system designs with low carbon dioxide equivalent emissions, suitable for new installations.

Fricke, Brian A [ORNL] [ORNL; Abdelaziz, Omar [ORNL] [ORNL; Vineyard, Edward Allan [ORNL] [ORNL

2013-01-01T23:59:59.000Z

420

Evaporative system for water and beverage refrigeration in hot countries  

E-Print Network [OSTI]

Evaporative system for water and beverage refrigeration in hot countries A Saleh1 and MA Al-Nimr2 1 Abstract: The present study proposes an evaporative refrigerating system used to keep water or other are found to be consistent with the available literature data. Keywords: evaporative refrigeration, heat

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Control method for mixed refrigerant based natural gas liquefier  

DOE Patents [OSTI]

In a natural gas liquefaction system having a refrigerant storage circuit, a refrigerant circulation circuit in fluid communication with the refrigerant storage circuit, and a natural gas liquefaction circuit in thermal communication with the refrigerant circulation circuit, a method for liquefaction of natural gas in which pressure in the refrigerant circulation circuit is adjusted to below about 175 psig by exchange of refrigerant with the refrigerant storage circuit. A variable speed motor is started whereby operation of a compressor is initiated. The compressor is operated at full discharge capacity. Operation of an expansion valve is initiated whereby suction pressure at the suction pressure port of the compressor is maintained below about 30 psig and discharge pressure at the discharge pressure port of the compressor is maintained below about 350 psig. Refrigerant vapor is introduced from the refrigerant holding tank into the refrigerant circulation circuit until the suction pressure is reduced to below about 15 psig, after which flow of the refrigerant vapor from the refrigerant holding tank is terminated. Natural gas is then introduced into a natural gas liquefier, resulting in liquefaction of the natural gas.

Kountz, Kenneth J. (Palatine, IL); Bishop, Patrick M. (Chicago, IL)

2003-01-01T23:59:59.000Z

422

Feasibility of Solar-Assisted Refrigerated Transport in Australia  

E-Print Network [OSTI]

systems. Keywords: refrigeration, transport, photovoltaics, economics. 1 #12;B. Elliston, M. Dennis) modules to minimise the use of diesel generation in refrigerated transport. Sub- sequently, UK supermarket. This report investigates the merit of retrofitting a PV system to assist refrigerated trailers in Australian

423

Literature survey of heat transfer enhancement techniques in refrigeration applications  

SciTech Connect (OSTI)

A survey has been performed of the technical and patent literature on enhanced heat transfer of refrigerants in pool boiling, forced convection evaporation, and condensation. Extensive bibliographies of the technical literature and patents are given. Many passive and active techniques were examined for pure refrigerants, refrigerant-oil mixtures, and refrigerant mixtures. The citations were categorized according to enhancement technique, heat transfer mode, and tube or shell side focus. The effects of the enhancement techniques relative to smooth and/or pure refrigerants were illustrated through the discussion of selected papers. Patented enhancement techniques also are discussed. Enhanced heat transfer has demonstrated significant improvements in performance in many refrigerant applications. However, refrigerant mixtures and refrigerant-oil mixtures have not been studied extensively; no research has been performed with enhanced refrigerant mixtures with oil. Most studies have been of the parametric type; there has been inadequate examination of the fundamental processes governing enhanced refrigerant heat transfer, but some modeling is being done and correlations developed. It is clear that an enhancement technique must be optimized for the refrigerant and operating condition. Fundamental processes governing the heat transfer must be examined if models for enhancement techniques are to be developed; these models could provide the method to optimize a surface. Refrigerant mixtures, with and without oil present, must be studied with enhancement devices; there is too little known to be able to estimate the effects of mixtures (particularly NARMs) with enhanced heat transfer. Other conclusions and recommendations are offered.

Jensen, M.K.; Shome, B. [Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Mechanical Engineering, Aeronautical Engineering and Mechanics

1994-05-01T23:59:59.000Z

424

Method and apparatus for de-superheating refrigerant  

DOE Patents [OSTI]

The present invention is an apparatus and method for de-superheating a primary refrigerant leaving a compressor wherein a secondary refrigerant is used between the primary refrigerant to be de-superheated. Reject heat is advantageously used for heat reclaim. 7 figs.

Zess, J.A.; Drost, M.K.; Call, C.J.

1997-11-25T23:59:59.000Z

425

Cooling of superconducting devices by liquid storage and refrigeration unit  

DOE Patents [OSTI]

A system is disclosed for cooling superconducting devices. The system includes a cryogen cooling system configured to be coupled to the superconducting device and to supply cryogen to the device. The system also includes a cryogen storage system configured to supply cryogen to the device. The system further includes flow control valving configured to selectively isolate the cryogen cooling system from the device, thereby directing a flow of cryogen to the device from the cryogen storage system.

Laskaris, Evangelos Trifon; Urbahn, John Arthur; Steinbach, Albert Eugene

2013-08-20T23:59:59.000Z

426

Active Diesel Emission Control Technology for Transport Refrigeration Units  

Broader source: Energy.gov [DOE]

This project discusses a CARB Level 2+ verified active regeneration technology for smal diesel engines

427

2014-04-10 Issuance: Test Procedures for Refrigerators, Refrigerator-Freezers, and Freezers; Final Rule  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule regarding test procedures for residential refrigerators and freezers, as issued by the Deputy Assistant Secretary for Energy Efficiency on April 10, 2014.

428

The New York Power Authority`s energy-efficient refrigerator program for the New York City Housing Authority -- 1997 savings evaluation  

SciTech Connect (OSTI)

This document describes the estimation of the annual energy savings achieved from the replacement of 20,000 refrigerators in New York City Housing Authority (NYCHA) public housing with new, highly energy-efficient models in 1997. The US Department of Housing and Urban Development (HUD) pays NYCHA`s electricity bills, and agreed to reimburse NYCHA for the cost of the refrigerator installations. Energy savings over the lifetime of the refrigerators accrue to HUD. Savings were demonstrated by a metering project and are the subject of the analysis reported here. The New York Power Authority (NYPA) identified the refrigerator with the lowest life-cycle cost, including energy consumption over its expected lifetime, through a request for proposals (RFP) issued to manufacturers for a bulk purchase of 20,000 units in 1997. The procurement was won by Maytag with a 15-ft{sup 3} top-freezer automatic-defrost refrigerator rated at 437 kilowatt-hours/year (kWh/yr). NYCHA then contracted with NYPA to purchase, finance, and install the new refrigerators, and demanufacture and recycle materials from the replaced units. The US Department of Energy (DOE) helped develop and plan the project through the ENERGY STAR{reg_sign} Partnerships program conducted by its Pacific Northwest National Laboratory (PNNL). PNNL designed the metering protocol and occupant survey used in 1997, supplied and calibrated the metering equipment, and managed and analyzed the data collected by NYPA. The objective of the 1997 metering study was to achieve a general understanding of savings as a function of refrigerator label ratings, occupant effects, indoor and compartment temperatures, and characteristics (such as size, defrost features, and vintage). The data collected in 1997 was used to construct models of refrigerator energy consumption as a function of key refrigerator and occupant characteristics.

Pratt, R.G.; Miller, J.D.

1998-09-01T23:59:59.000Z

429

Waste Heat Recapture from Supermarket Refrigeration Systems  

SciTech Connect (OSTI)

The objective of this project was to determine the potential energy savings associated with improved utilization of waste heat from supermarket refrigeration systems. Existing and advanced strategies for waste heat recovery in supermarkets were analyzed, including options from advanced sources such as combined heat and power (CHP), micro-turbines and fuel cells.

Fricke, Brian A [ORNL

2011-11-01T23:59:59.000Z

430

Covered Product Category: Refrigerated Beverage Vending Machines  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including refrigerated beverage vending machines, which are covered by the ENERGY STAR® program. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

431

International Refrigeration: Proposed Penalty (2012-CE-1510) | Department  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

International Refrigeration: Proposed Penalty (2012-CE-1510) International Refrigeration: Proposed Penalty (2012-CE-1510) International Refrigeration: Proposed Penalty (2012-CE-1510) July 9, 2012 DOE alleged in a Notice of Proposed Civil Penalty that International Refrigeration Products failed to certify a various room air conditioners as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. International Refrigeration: Proposed Penalty (2012-CE-1510) More Documents & Publications

432

Case Study: Transcritical Carbon Dioxide Supermarket Refrigeration Systems  

Broader source: Energy.gov [DOE]

This case study documents one year of operating experience with a transcritical carbon dioxide (TC CO2) booster refrigeration system at Delhaize America’s Hannaford supermarket location in Turner, Maine. This supermarket, which began operation in June 2013, is the first supermarket installation in the U.S. of a TC CO2 booster refrigeration system. We compare refrigeration system performance to that for a supermarket having nearly identical layout and refrigeration loads, in a similar climate and of similar vintage, that uses a conventional hydrofluorocarbon (HFC) refrigerant. Delhaize provided the submetered and utility data used to generate the performance summaries herein.

433

Special dilution refrigerator systems of Milli-Kelvin detector experiments  

SciTech Connect (OSTI)

Several hundred ultra low temperature systems have been designed and built for a variety of applications. One common application is the refrigeration of low temperature detectors. Although many of the requirements are satisfied by standard designs, Oxford Instruments has often built special refrigerators to suit specific detector requirements. A few of the most interesting of these systems will be discussed. (1) dilution refrigerators to cool gravitational wave antennae to 65 mK; (2) rotating dilution refrigerator for cosmic ray detector experiments; (3) compact dilution refrigerator to cool large bolometer arrays within the SCUBA telescope; (4) side access systems for beam line experiments

Batey, G.; Balshaw, N. (Oxford Instruments Ltd., Old Station Way (United Kingdom))

1993-11-01T23:59:59.000Z

434

Retail refrigeration systems -- The use of ammonia and two-level secondary refrigeration  

SciTech Connect (OSTI)

The concept of a secondary refrigeration system for high-temperature use as investigated in 1991, and a design for a full high-temperature system was completed the following year. In late 1992, a supermarket chain commissioned a study of the feasibility of turning the design into a practical application and assisted the project in 1993 by commissioning a test facility for single-temperature secondary refrigeration at one of the company`s factory sites. Results and conclusions from this trial work pointed toward the need for a total secondary refrigeration system, including a low-temperature system for frozen food display cases, and the possibility of utilizing environmentally friendly ammonia as the primary refrigerant. Therefore, in late 1993/early 1994, a low-temperature system was developed and commissioned at the test facility. Full collaboration between the supermarket company and the contractor resulted in the funding of practical trial work and feasibility studies for both secondary refrigeration and a fully detailed proposal for the use of ammonia in a public retail environment. In May 1995, the first UK ammonia and two-level secondary refrigeration system began operation in a supermarket in Horsham, Sussex England.

Thomas, A.S. [Westward Refrigeration, Gloucester (United Kingdom)

1998-10-01T23:59:59.000Z

435

" Million U.S. Housing Units"  

U.S. Energy Information Administration (EIA) Indexed Site

6 Air Conditioning Characteristics by Climate Zone, 2005" 6 Air Conditioning Characteristics by Climate Zone, 2005" " Million U.S. Housing Units" ,,"Climate Zone1" ,,"Less than 2,000 CDD and --",,,,"2,000 CDD or More and Less than 4,000 HDD" ,"Housing Units (millions)" ,,"Greater than 7,000 HDD","5,500 to 7,000 HDD","4,000 to 5,499 HDD","Less than 4,000 HDD" "Air Conditioning Characteristics" "Total",111.1,10.9,26.1,27.3,24,22.8 "Do Not Have Cooling Equipment",17.8,3.2,4.7,3.6,5.5,0.9 "Have Cooling Equipment",93.3,7.7,21.4,23.7,18.5,21.9 "Use Cooling Equipment",91.4,7.6,21,23.4,17.9,21.7 "Have Equipment But Do Not Use it",1.9,"Q",0.4,0.4,0.6,0.3

436

Field test of a high efficiency, automatic defrost refrigerator-freezer  

SciTech Connect (OSTI)

This paper describes the market evaluation and field test portion of a program to design, develop, and demonstrate a high efficiency, automatic defrosting refrigerator-freezer for the residential market. After the successful completion of Phase I of the program, which concentrated on the design, construction, and laboratory testing of a 453 1 (16 ft/sup 3/) high-efficiency refrigerator-freezer prototype, Phase II was initiated in February 1979 to evaluate the sales potential and performance of the high-efficiency refrigerator concept under field conditions, as a necessary step in creating a product that was both manufacturable and marketable. In Phase I, a survey of food consumption and storage trends, family size, and consumer buying habits led to a sales-weighted average-capacity forecast for 1985 of approximately 453 1 (16 ft/sup 3/) and identification of the top-mount, automatic defrosting refrigerator as the projected sales leader. To meet this market demand, a 453 1 (16 ft/sup 3/) top-mount was selected as the baseline for the Phase I design and development. In Phase II, a 509 1 (18 ft/sup 3/) unit using Phase I technology was chosen for the field test, since the slightly larger model better fit the participating manufacturer's new product development efforts and market.

Topping, R.F.; Vineyard, E.A.

1982-01-01T23:59:59.000Z

437

Building Technologies Office: Low-Global Warming Potential Refrigerants  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Low-Global Warming Low-Global Warming Potential Refrigerants Research Project to someone by E-mail Share Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Facebook Tweet about Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Twitter Bookmark Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Google Bookmark Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Delicious Rank Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Digg Find More places to share Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on AddThis.com... About Take Action to Save Energy

438

Solar-powered cooling system  

DOE Patents [OSTI]

A solar-powered adsorption-desorption refrigeration and air conditioning system uses nanostructural materials made of high specific surface area adsorption aerogel as the adsorptive media. Refrigerant molecules are adsorbed on the high surface area of the nanostructural material. A circulation system circulates refrigerant from the nanostructural material to a cooling unit.

Farmer, Joseph C

2013-12-24T23:59:59.000Z

439

Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating Ventilation and Air Conditioning (HVAC) system for the HIE-ISOLDE infrastructure  

E-Print Network [OSTI]

Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating Ventilation and Air Conditioning (HVAC) system for the HIE-ISOLDE infrastructure

2012-01-01T23:59:59.000Z

440

Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre  

E-Print Network [OSTI]

Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

The alternative refrigerant dilemma for refrigerator-freezers: Truth or consequences  

SciTech Connect (OSTI)

In an effort to select a refrigerant that has minimal impact on energy consumption and the environment, a screening analysis of potential refrigerants was performed that resulted in the selection of six candidates. The screening results show that R-134a, R-134, R-152a, R-134a/R-152a, R-22/R-152a/R-124, and R-134a/R-152a/R-124 are the most promising refrigerants based on the following criteria: ozone depletion potential, greenhouse warming potential, coefficient of performance, and safety. Energy consumption tests were performed for the three pure refrigerants in accordance with the Association of Home Appliance Manufacturers standard for household refrigerators and household freezers. The results indicate an increased energy consumption of 6.8%, 7.3%, and 7.3%, respectively for R-134, R-152a, and R-134a in the most efficient oil. However, when the effects of compressor efficiency are taken into account, the normalized energy consumption results in an increase of only 2.7% for R-152a and 5.5% for both R-134a and R-134. 14 refs., 5 tabs.

Vineyard, E.A.

1991-01-01T23:59:59.000Z

442

International Refrigeration: Order (2012-CE-1510)  

Broader source: Energy.gov (indexed) [DOE]

WASHINGTON, D.C. 20585 WASHINGTON, D.C. 20585 Case Number: 2012-CE-1510 International Refrigeration Products, Respondent ) ) ) ) ) ) ORDER Issued: July 20, 2012 By the General Counsel, U.S. Department of Energy: 1. In this Order, I adopt the attached Compromise Agreement entered into between the U.S. Department of Energy ("DOE") and International Refrigeration Products ("Respondent"). The Compromise Agreement resolves the case initiated to pursue a civil penalty for violations of the compliance certification requirements located at 10 C.P.R. § 429.12. 2. DOE and Respondent have negotiated the terms of the Compromise Agreement that resolve this matter. A copy of the Compromise Agreement is attached hereto and incorporated by reference. 3. After reviewing the terms of the Compromise Agreement and evaluating the facts

443

An electric utility's adventures in commercial refrigeration  

SciTech Connect (OSTI)

This article provides a look at the history of energy conservation efforts in supermarket refrigeration from World War II to the present and a goal for the future. A supermarket is a low profit margin business, typically netting 1 percent on annual sales. The typical supermarket's annual electric bill equals or exceeds the annual profits. With all of these data, it looked like energy conservation in the supermarket industry was going to be an easy task. Change the lighting to a more energy-efficient system and lower the head pressure and raise the suction pressure in the refrigeration. Any owner, CEO, or general manager who could easily increase his bottom-line profit by 10 to 30 percent would jump at the opportunity, especially when the electric utility was willing to support a portion of the cost for the changes.

Flannick, J.A. (Wisconsin Electric Co., Milwaukee, WI (United States)); Stamm, R.H. (Industrial Refrigeration, Sandy, OR (United States)); Calle, M.M. (Technical Resources, Inc., Milwaukee, WI (United States)); Gomolla, J.C. (Gomolla (Jerry C.), Milwaukee, WI (United States))

1994-10-01T23:59:59.000Z

444

Performance bound for quantum absorption refrigerators  

E-Print Network [OSTI]

An implementation of quantum absorption chillers with three qubits has been recently proposed, that is ideally able to reach the Carnot performance regime. Here we study the working efficiency of such self-contained refrigerators, adopting a consistent treatment of dissipation effects. We demonstrate that the coefficient of performance at maximum cooling power is upper bounded by 3/4 of the Carnot performance. The result is independent of the details of the system and the equilibrium temperatures of the external baths. We provide design prescriptions that saturate the bound in the limit of a large difference between the operating temperatures. Our study suggests that delocalized dissipation, which must be taken into account for a proper modelling of the machine-baths interaction, is a fundamental source of irreversibility which prevents the refrigerator from approaching the Carnot performance arbitrarily closely in practice. The potential role of quantum correlations in the operation of these machines is also investigated.

Luis A. Correa; José P. Palao; Gerardo Adesso; Daniel Alonso

2012-12-18T23:59:59.000Z

445

The application of Stirling cooler to refrigeration  

SciTech Connect (OSTI)

The application field of the free-piston Stirling Cooler, Model 100A of Global Cooling BV in the refrigeration has been studied. The cooling effectiveness of the free-piston Stirling Cooler which means small capacity with better efficiency, large range of temperature and capacity modulated operation is of much use to cool a space insulated well. One practicable application is suggested here, in which FPSC and secondary heat transfer fluid are used to the single temperature refrigerator (60 liter) instead of conventional vapor compression machines. In the freezer operation at {minus}20 C inside cabinet, the steady-state test results show 25% improvement in energy consumption over original one. The application of free-piston Stirling Cooler to a freezer at lower temperature shows great potentials also.

Kim, S.Y.; Chung, W.S.; Shin, D.K.; Cho, K.S. [LG Electronics Inc., Seoul (Korea, Republic of). Living System Lab.

1997-12-31T23:59:59.000Z

446

Process for the production of refrigerator oil  

SciTech Connect (OSTI)

A process for producing a high quality refrigerator oil from an oil fraction boiling at a temperature within boiling point of lubricating oil by contacting said oil fraction with a solvent to extract undesirable components thereby lowering % C..cap alpha.. of said oil fraction, hydrogenating said solvent extracted fraction under the specific conditions, and then contacting said hydrogenated oil with a solid absorbant to remove impurities; said oil fraction being obtained from a low grade naphthenic crude oil.

Kunihiro, T.; Tsuchiya, K.

1985-06-04T23:59:59.000Z

447

Tapered pulse tube for pulse tube refrigerators  

DOE Patents [OSTI]

Thermal insulation of the pulse tube in a pulse-tube refrigerator is maintained by optimally varying the radius of the pulse tube to suppress convective heat loss from mass flux streaming in the pulse tube. A simple cone with an optimum taper angle will often provide sufficient improvement. Alternatively, the pulse tube radius r as a function of axial position x can be shaped with r(x) such that streaming is optimally suppressed at each x.

Swift, Gregory W. (Sante Fe, NM); Olson, Jeffrey R. (San Mateo, CA)

1999-01-01T23:59:59.000Z

448

Field usage and its impact on energy consumption of refrigerator/freezers  

SciTech Connect (OSTI)

This study investigated the effect of door openings and kitchen environment on the energy consumption of nine household refrigerator/freezers (R/Fs) in the field. The factors under consideration include fresh food and freezer door openings, length of door openings, ambient kitchen temperature, and kitchen relative humidity (RH). Average daily energy consumption for the nine units ranged from 1.7 to 5.3 kWh/day. Energy consumption was found to correlate with kitchen temperature and the number of door openings. No dependence on kitchen relative humidity was found. In general, the magnitude of the door opening component of energy consumption was higher for the more efficient units.

Gage, C.L. [Environmental Protection Agency, Research Triangle Park, NC (United States). Air Pollution Prevention and Control Div.

1995-12-31T23:59:59.000Z

449

The impacts of duct design on life cycle costs of central residential heating and air-conditioning systems  

Science Journals Connector (OSTI)

Abstract Many central residential HVAC systems in the U.S. operate at high external static pressures due to a combination of system restrictions. Undersized and constricted ductwork are thought to be key culprits that lead to excess external static pressures in many systems, although the magnitude of energy impacts associated with restrictive ductwork and the costs or benefits associated with addressing the problem are not well known. Therefore, this work uses annual energy simulations of two typical new single-family homes in two separate climates in the United States (Austin, TX and Chicago, IL) to predict the impacts of various external static pressure ductwork designs from independent HVAC contractors (using both flexible and rigid sheet metal ductwork materials) on annual space conditioning energy use. Results from the simulations are combined with estimates of the initial installation costs of each duct design made by each contractor to evaluate the total life cycle costs or savings of using lower pressure duct designs in the two homes over a 15-year life cycle. Lower pressure ductwork systems generally yielded life cycle cost savings, particularly in homes with PSC blowers and particularly when making comparisons with constant ductwork materials (i.e., comparing flex only or rigid only).

Brent Stephens

2014-01-01T23:59:59.000Z

450

Geothermal Energy Development in the Eastern United States: Technical assistance report No. 6 geothermal space heating and airconditioning -- McGuire Air Force Base, New Jersey  

SciTech Connect (OSTI)

A method of utilizing the geothermal (66 F) water resource for space heating and cooling of 200 of the 1452 housing units at McGuire AFB is suggested. Using projections of future costs of gas, coal and electricity made by DOD and by industry (Westinghouse), the relative costs of the geothermal-water-plus-heat-pump system and the otherwise-planned central gas heating (to be converted to coal in 1984) and air-conditioning (using individual electric units) system are compared. For heating with the geothermal/heat-pump system, an outlet temperature of 130 F is selected, requiring a longer running time than the conventional system (at 180 F) but permitting a COP (coefficient of performance) of the heat pump of about 3.4. For cooling (obtained in this study by changing directions of water flow, not refrigerant cycles), the change in temperature is less, and a COP near 4.5 is obtained. The cost of cooling in the summer months would be significantly less than the cost of using individual electric air-conditioners. Thus, by using nonreversible heat pumps, geothermal water is used to heat and to cool a section of the housing compound, minimizing operating expenditures. It is estimated that, to drill 1000 ft deep production and reinjection wells and to install ten heat pumps, heat exchangers and piping, would require a capital outlay of $643 K. This cost would replace the capital cost of purchasing and installing 200 air-conditioning units and 14% of the cost of the future coal-fired central heating system (which would otherwise serve all 1452 housing units at McGuire). The net additional capital outlay would be $299 K, which could be amortized in 10 years by the lower operating cost of the geothermal system if electricity and coal prices escalate as industry suggests. If the coal and electricity costs rise at the more modest rates that DOD projects, the capital costs would be amortized in a 15 year period.

Hill, F.K.; Briesen R. von

1980-12-01T23:59:59.000Z

451

DOE Opens Three Investigations into Alleged Refrigerator Efficiency  

Broader source: Energy.gov (indexed) [DOE]

Opens Three Investigations into Alleged Refrigerator Efficiency Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations April 12, 2010 - 7:27pm Addthis The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that failed to meet federal energy efficiency standards. Under the subpoena, Arçelik A.S, a Turkish Company is required to submit detailed information about the design, marketing and U.S. sales of its Blomberg brand refrigerator-freezer, model "BRFB1450." The Department also requested testing data from Whirlpool Corporation and Viking Range Corporation for two refrigerator-freezers that the companies

452

Could You Save Money on Your Refrigerator? | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? July 20, 2012 - 4:35pm Addthis Earlier this week, Amanda wrote about how you can save energy by choosing the right refrigerator and using it efficiently. These tips explain all sorts of ways you can ensure your refrigerator uses as little energy as possible to keep itself cool. So this week, we're curious: Could you save money with your refrigerator? You have the chance to share your thoughts on a question about energy efficiency or renewable energy for consumers. E-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov. Addthis Related Articles How Do You Save Money on Summer Holidays? Have You Seen Energy Efficiency Improvements in Your Neighborhood?

453

DOE Opens Three Investigations into Alleged Refrigerator Efficiency  

Broader source: Energy.gov (indexed) [DOE]

Opens Three Investigations into Alleged Refrigerator Efficiency Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations April 12, 2010 - 7:27pm Addthis The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that failed to meet federal energy efficiency standards. Under the subpoena, Arçelik A.S, a Turkish Company is required to submit detailed information about the design, marketing and U.S. sales of its Blomberg brand refrigerator-freezer, model "BRFB1450." The Department also requested testing data from Whirlpool Corporation and Viking Range Corporation for two refrigerator-freezers that the companies

454

Could You Save Money on Your Refrigerator? | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? July 20, 2012 - 4:35pm Addthis Earlier this week, Amanda wrote about how you can save energy by choosing the right refrigerator and using it efficiently. These tips explain all sorts of ways you can ensure your refrigerator uses as little energy as possible to keep itself cool. So this week, we're curious: Could you save money with your refrigerator? You have the chance to share your thoughts on a question about energy efficiency or renewable energy for consumers. E-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov. Addthis Related Articles How Do You Save Money on Summer Holidays? Have You Seen Energy Efficiency Improvements in Your Neighborhood?

455

Compressor calorimeter performance of refrigerant blends: Comparative methods and results for a refrigerator/freezer application  

SciTech Connect (OSTI)

A protocol was developed to define calorimeter operating pressures for nonazeotropic refrigerant mixtures (NARMs) which corresponded with the saturated evaporator and condenser temperatures commonly used for pure refrigerants. Compressor calorimeter results were obtained using this equivalent-mean-temperature (EMT) approach and a generally applied Association of Home Appliance Manufacturers (AHAM) procedure at conditions characteristic of a domestic refrigerator-freezer application. Tests with R-12 and two NARMs indicate that compressor volumetric and isentropic efficiencies are nearly the same for refrigerants with similar capacities and pressure ratios. The liquid-line temperature conditions specified in the AHAM calorimeter rating procedure for refrigerator-freezer compressors were found to preferentially derate NARM performance relative to R-12. Conversion of calorimeter data taken with a fixed liquid-line temperature to a uniform minimal level of condenser subcooling is recommended as a fairer procedure when NARMs are involved. Compressor energy-efficiency-ratio (EER) and capacity data measured as a result of the EMT approach were compared to system performance calculated using an equivalent-heat-exchanger-loading (EHXL) protocol based on a Lorenz-Meutzner (L-M) refrigerator-freezer modeling program. The EHXL protocol was used to transform the calorimeter results into a more relevant representation of potential L-M cycle performance. The EMT method used to set up the calorimeter tests and the AHAM liquid-line conditions combined to significantly understate the cycle potential of NARMs relative to that predicted at the more appropriate EHXL conditions. Compressor conditions representative of larger heat exchanger sizes were also found to give a smaller L-M cycle advantage relative to R-12.

Rice, C K; Sand, J R

1993-01-01T23:59:59.000Z

456

Process Options for Nominal 2-K Helium Refrigeration System Designs  

SciTech Connect (OSTI)

Nominal 2-K helium refrigeration systems are frequently used for superconducting radio frequency and magnet string technologies used in accelerators. This paper examines the trade-offs and approximate performance of four basic types of processes used for the refrigeration of these technologies; direct vacuum pumping on a helium bath, direct vacuum pumping using full or partial refrigeration recovery, cold compression, and hybrid compression (i.e., a blend of cold and warm sub-atmospheric compression).

Peter Knudsen, Venkatarao Ganni

2012-07-01T23:59:59.000Z

457

Hydrophilic structures for condensation management in refrigerator appliances  

DOE Patents [OSTI]

A refrigerator appliance that includes a freezer compartment having a freezer compartment door, and a refrigeration compartment having at least one refrigeration compartment door. The appliance further includes a mullion with an exterior surface. The mullion divides the compartments and the exterior surface directs condensation toward a transfer point. The appliance may also include a cabinet that houses the compartments and has two sides, each with an exterior surface. Further, at least one exterior surface directs condensation toward a transfer point.

Kuehl, Steven John; Vonderhaar, John J; Wu, Guolian; Wu, Mianxue

2014-10-21T23:59:59.000Z

458

Microcomputer Software for Refrigerant Property and Cycle Analysis Calculations  

E-Print Network [OSTI]

cost, a large component of which is energy-related. Existing system operation must be analyzed to optimize energy consumption while still meeting cooling load requirements. Refrigerant properties, which form the basis for such calculations, have... to illustrate the application of the program to problems in design and operation of refrigeration systems. INTRODUCTION Thermodynamic analysis of refrigeration systems is important in a variety. of industrial; commercial, and building-related applications...

Bierschenk, J. L.; Strohl, S. T.; Schmidt, P. S.

459

Lubricant return comparison of naphthenic and polyol ester oils in R-134a household refrigeration applications  

SciTech Connect (OSTI)

This paper presents mineral oils and polyol esters as possible lubricant options for domestic refrigeration applications employing R-134a as the heat exchange fluid. A performance comparison, based on data presented, is made between the mineral oils and polyol esters evaluated. To more closely examine lubricant return with N-70 and R-134a and ensure that the oil is not contributing to any deterioration in efficiency due to its accumulation in evaporators, a special test unit was designed with a difficult oil return configuration and its performance carefully monitored. Oil return with a hydrofluorocarbon-miscible polyol ester, R-133-O was also evaluated in this setup and its performance results compared to those obtained with the naphthenic refrigeration oil.

Reyes-Gavilan, J.L.; Flak, G.T.; Tritcak, T.R. [Witco Corp., Oakland, NJ (United States)

1996-12-31T23:59:59.000Z

460

Helium Refrigerator Design for Pulsed Heat Load in Tokamaks  

SciTech Connect (OSTI)

Nuclear fusion reactors of the Tokamak type will be operated in a pulsed mode requiring the helium refrigerator to remove periodically large heat loads in time steps of approximately one hour. What are the necessary steps for a refrigerator to cope with such load variations?A series of numerical simulations has been performed indicating the possibility of an active refrigerator control with low exergetic losses. A basic comparison is made between the largest existing refrigerator sizes and the size required to service for example the ITER requirements.

Kuendig, A.; Schoenfeld, H. [Linde Kryotechnik AG, Dattlikonerstrasse 5, CH-8422 Pfungen (Switzerland)

2006-04-27T23:59:59.000Z

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Supermarket refrigeration assessment for the New England Electric System  

SciTech Connect (OSTI)

The Electric Power Research Institute (EPRI) has undertaken a project to assess the impact of energy efficient supermarket refrigeration on the electric capacity requirements of the New England Electric System (NEES) service territories. The leading supermarket chains in the NEES service territories were contacted and the number of supermarkets and the types of refrigeration systems employed were established. Estimates were then made of the potential demand and energy savings that NEES and the supermarkets could realize if energy efficient refrigeration systems were employed. On the basis of this analysis, possible incentives to accelerate the implementation of energy efficient refrigeration equipment in NEES service territories were recommended. 4 refs., 10 figs., 27 tabs.

Tsaros, T.L.; Walker, D.H. (Foster-Miller, Inc., Waltham, MA (United States))

1991-07-01T23:59:59.000Z

462

Economizer refrigeration cycle space heating and cooling system and process  

DOE Patents [OSTI]

This invention relates to heating and cooling systems and more particularly to an improved system utilizing a Stirling Cycle engine heat pump in a refrigeration cycle. 18 figs.

Jardine, D.M.

1983-03-22T23:59:59.000Z

463

Economizer refrigeration cycle space heating and cooling system and process  

DOE Patents [OSTI]

This invention relates to heating and cooling systems and more particularly to an improved system utilizing a Stirling Cycle engine heat pump in a refrigeration cycle.

Jardine, Douglas M. (Colorado Springs, CO)

1983-01-01T23:59:59.000Z

464

List of Commercial Refrigeration Equipment Incentives | Open Energy  

Open Energy Info (EERE)

Refrigeration Equipment Incentives Refrigeration Equipment Incentives Jump to: navigation, search The following contains the list of 103 Commercial Refrigeration Equipment Incentives. CSV (rows 1 - 103) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Appalachian Power - Commercial and Industrial Rebate Programs (West Virginia) Utility Rebate Program West Virginia Commercial Industrial Central Air conditioners Chillers Custom/Others pending approval Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Programmable Thermostats Commercial Refrigeration Equipment Ground Source Heat Pumps Yes AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility

465

South Africa Sectoral Study on Climate and Refrigeration Technology...  

Open Energy Info (EERE)

Reduction Potential and Implementing NAMAs Jump to: navigation, search Name South Africa-Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the...

466

Polyhalogenated hydrocarbon refrigerants and refrigerant oils colored with fluorescent dyes and method for their use as leak detectors  

SciTech Connect (OSTI)

A leak detectable refrigeration composition is described comprising: (A) a refrigeration liquid selection from the group consisting of: (1) a polyhalogenated hydrocarbon refrigerant; (2) a refrigeration oil selected from the group consisting of naphthenic oils, paraffinic oils, alkylated benzenes, silicones, polyglycols, diesters or triesters of dicarboxylic or tricarboxylic acids, and polyalkyl silicate oils, and (3) a mixture of A(1) and A(2), and (B) a fluorescent dye compound or composition comprising the dye selected from the group consisting of: (1) a fluorescent dye selected from the group consisting of perylene, naphthoxanthene, monocyclic aromatic compounds having an organometallic compound, (2) a solution of fluorescent dye in a solvent, and (3) a mixture of B(1) and B(2). The fluorescent dye compound or composition is soluble in the refrigeration liquid. The concentration of the dye being at least 0.001 grams per 100 grams of the refrigeration liquid.

Parekh, M.

1988-07-19T23:59:59.000Z

467

Exergy analysis and experimental study of a vapor compression refrigeration cycle  

Science Journals Connector (OSTI)

This article presents a detailed experimental analysis of 2TR (ton of refrigeration) vapor compression refrigeration cycle for different percentage of refrigerant charge using exergy analysis. An experimental set...

S. Anand; S. K. Tyagi

2012-11-01T23:59:59.000Z

468

September 2013 Most Viewed Documents for Environmental Sciences...  

Office of Scientific and Technical Information (OSTI)

Soil Friday, G. P. (1999) 31 > Ammonia usage in vapor compression for refrigeration and air-conditioning in the United States Fairchild, P.D.; Baxter, V.D. (1995) 30 >...

469

Development of a high-efficiency, automatic-defrosting refrigerator-freezer. Phase II. Field test. Volume III. Executive summary and task reports  

SciTech Connect (OSTI)

The second phase of the development of a high-efficiency, automatic-defrosting, refrigerator-freezer is described. Following the successful completion of Phase I (design, construction, and laboratory testing of a 16 ft/sup 3/ high efficiency refrigerator-freezer prototype), Phase II was initiated to evaluate sales potential and in-home performance as a necessary step in creating a product that was both manufacturable and marketable. Twenty-five pilot production 18 ft/sup 3/ units using prototype tooling were produced on the assembly line to confirm the feasibility of full-scale production. These units were then used in a market and field test program in which consumer appeal and in-home performance were assessed. The market evaluation confirmed that refrigerators incorporating high-efficiency features at added cost are saleable and that large capacity, automatic-defrosting, refrigerator-freezers will continue to capture a large portion of the market in the years ahead, The field test confirmed the in-home energy saving potential of a high efficiency, automatic-defrosting refrigerator-frezer utilizing advanced design features such as optimized, thick-wall, foam an average energy savings of 60% compared to a baseline unit of conventional design.

Topping, R.F.

1982-12-01T23:59:59.000Z

470

Cascade and secondary coolant supermarket refrigeration systems : modelling and new frost correlations.  

E-Print Network [OSTI]

??Nowadays traditional (direct expansion) supermarket refrigeration systems are mostly employed in supermarket establishments for refrigerating food products and beverages in the store. However, the installations… (more)

Haile-Michael, Getu

2011-01-01T23:59:59.000Z

471

HgCdTe superlattices for solid-state cryogenic refrigeration  

E-Print Network [OSTI]

for solid-state cryogenic refrigeration Daryoosh Vashaee a?merit ?ZT max ? 3? at cryogenic temperatures. Calculationstemperature, 1–6 for cryogenic refrigeration the situation

Vashaee, D; Shakouri, A

2006-01-01T23:59:59.000Z

472

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network [OSTI]

refrigerator operate with propane as well as electricity?refrigerator operate with propane as well as electricity? [freezer operate with propane as well as electricity? [

Greenblatt, Jeffery B.

2014-01-01T23:59:59.000Z

473

Definition: British thermal unit | Open Energy Information  

Open Energy Info (EERE)

thermal unit thermal unit Jump to: navigation, search Dictionary.png British thermal unit The amount of heat required to raise the temperature of one pound of water one degree Fahrenheit; often used as a unit of measure for the energy content of fuels.[1][2] View on Wikipedia Wikipedia Definition The British thermal unit (BTU or Btu) is a traditional unit of energy equal to about 1055 joules. It is the amount of energy needed to cool or heat one pound of water by one degree Fahrenheit. In scientific contexts the BTU has largely been replaced by the SI unit of energy, the joule. The unit is most often used as a measure of power (as BTU/h) in the power, steam generation, heating, and air conditioning industries, and also as a measure of agricultural energy production (BTU/kg). It is still used

474

Lanthanide Al-Ni base Ericsson cycle magnetic refrigerants  

DOE Patents [OSTI]

A magnetic refrigerant for a magnetic refrigerator using the Ericsson thermodynamic cycle comprises DyAlNi and (Gd{sub 0.54}Er{sub 0.46})AlNi alloys having a relatively constant {Delta}Tmc over a wide temperature range. 16 figs.

Gschneidner, K.A. Jr.; Takeya, Hiroyuki

1995-10-31T23:59:59.000Z

475

Lanthanide Al-Ni base Ericsson cycle magnetic refrigerants  

DOE Patents [OSTI]

A magnetic refrigerant for a magnetic refrigerator using the Ericsson thermodynamic cycle comprises DyAlNi and (Gd.sub.0.54 Er.sub.0.46)AlNi alloys having a relatively constant .DELTA.Tmc over a wide temperature range.

Gschneidner, Jr., Karl A. (Ames, IA); Takeya, Hiroyuki (Ibaraki, JP)

1995-10-31T23:59:59.000Z

476

Control of Refrigeration Systems for Trade-off between Energy  

E-Print Network [OSTI]

Control of Refrigeration Systems for Trade-off between Energy Consumption and Food Quality Loss Ph and Technology (DMST) under Grant: 2002-603/4001-93. CMBC consists of seven industrial companies, three academic of the three academic partners in the center. The refrigeration research activities within CMBC were initiated

Skogestad, Sigurd

477

NEW DESIGN OF NEON REFRIGERATOR FOR HTS POWER MACHINES  

Science Journals Connector (OSTI)

In 2007 we developed a prototype refrigerator with a small turbo?expander to provide adequate cooling power (2 kW at 70 K) for HTS (High Temperature Superconductor) power machines. The reverse?Brayton cycle with neon gas as a working fluid was adopted in the refrigerator. The prototype refrigerator does not have enough COP (Coefficient of Performance) for practical HTS applications and the purpose of this study is to research the information required for designing a new neon refrigerator with improved performance. We take the same refrigeration cycle and working fluid as the prototype one adopted but a lower process pressure of 1 MPa/0.5 MPa is chosen instead of 2 MPa/1 MPa. The lower process pressure is required by the turbo?compressor design and the refrigeration process is analyzed by using a newly developed process simulator. Also a heat?exchanger configuration is studied to make the refrigerator size small. The new refrigerator will have a cooling power of 2.5 kW at 65 K and a COP of 0.06 at 80 K.

S. Yoshida; H. Hirai; A. Takaike; M. Hirokawa; Y. Aizawa; Y. Kamioka; H. Okamoto; H. Hayashi; Y. Shiohara

2010-01-01T23:59:59.000Z

478

On-site Housing Unit Types | Staff Services  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

On-site Housing Unit Types On-site Housing Unit Types Registration is required for all computers, wireless notebooks or other network devices used on the BNL Network. Devices that are not registered will be disconnected from the network. Apartments Apartments are available in 1, 2, 3 and 4 bedrooms. They are fully furnished and supplied with linens, kitchen utensils and cookware. Utilities are included in the rental price. *Note: These units do NOT have air conditioning. Each unit is equipped with DSL connection, satellite television and a microwave. Cisco Wireless Access Points (WAPs) connections are also available in Buildings 2-10. More Photos (PDF) Cavendish House The Cavendish house is a male dormitory consisting of 83 private single occupancy rooms equipped with air conditioning, Ethernet connection and

479

North Star Refrigerator: Proposed Penalty (2013-CE-5355) | Department of  

Broader source: Energy.gov (indexed) [DOE]

North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) March 26, 2013 DOE alleged in a Notice of Proposed Civil Penalty that North Star Refrigerator Co., Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. North Star Refrigerator: Proposed Penalty (2013-CE-5355) More Documents & Publications

480

DOE Closes Investigation of Whirlpool's Maytag Refrigerator | Department of  

Broader source: Energy.gov (indexed) [DOE]

of Whirlpool's Maytag Refrigerator of Whirlpool's Maytag Refrigerator DOE Closes Investigation of Whirlpool's Maytag Refrigerator July 8, 2010 - 3:12pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Whirlpool's Maytag refrigerator-freezer model "MSD2578VE." The Department opened this investigation and requested testing data from Whirlpool based on a complaint (April 12, 2010, "DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations"). After reviewing the data and testing this model, the Department has found the model to be compliant with the applicable efficiency standards and has closed the investigation. The Department takes credible allegations seriously and will continue to initiate investigations on products that are

Note: This page contains sample records for the topic "refrigeration unit air-conditioning" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) |  

Broader source: Energy.gov (indexed) [DOE]

Duracold Refrigeration Manufacturing: Proposed Penalty Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) February 21, 2013 DOE alleged in a Notice of Proposed Civil Penalty that Duracold Refrigeration Manufacturing Company, LLC failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342)

482

DOE Closes Investigation of Whirlpool's Maytag Refrigerator | Department of  

Broader source: Energy.gov (indexed) [DOE]

Closes Investigation of Whirlpool's Maytag Refrigerator Closes Investigation of Whirlpool's Maytag Refrigerator DOE Closes Investigation of Whirlpool's Maytag Refrigerator July 8, 2010 - 3:12pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Whirlpool's Maytag refrigerator-freezer model "MSD2578VE." The Department opened this investigation and requested testing data from Whirlpool based on a complaint (April 12, 2010, "DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations"). After reviewing the data and testing this model, the Department has found the model to be compliant with the applicable efficiency standards and has closed the investigation. The Department takes credible allegations seriously and will continue to initiate investigations on products that are

483

DOE Proposes Higher Efficiency Standards for Refrigerators | Department of  

Broader source: Energy.gov (indexed) [DOE]

DOE Proposes Higher Efficiency Standards for Refrigerators DOE Proposes Higher Efficiency Standards for Refrigerators DOE Proposes Higher Efficiency Standards for Refrigerators September 28, 2010 - 12:00am Addthis WASHINGTON, DC - U.S. Energy Secretary Steven Chu today announced the release of a new proposed energy efficiency standard for residential refrigerators, refrigerator-freezers, and freezers. The standard, as proposed, could save consumers as much as $18.6 billion over thirty years. The Obama Administration has made efficiency standards a major priority as a way to save energy and money for American families and businesses. Since January 2009, the Department of Energy has finalized new efficiency standards for more than twenty household and commercial products, which will cumulatively save consumers between $250 billion and

484

North Star Refrigerator: Proposed Penalty (2013-CE-5355) | Department of  

Broader source: Energy.gov (indexed) [DOE]

North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) March 26, 2013 DOE alleged in a Notice of Proposed Civil Penalty that North Star Refrigerator Co., Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. North Star Refrigerator: Proposed Penalty (2013-CE-5355) More Documents & Publications

485

Modeling Supermarket Refrigeration Systems with EnergyPlus  

SciTech Connect (OSTI)

Supermarket refrigeration capabilities were first added to EnergyPlus in 2004. At that time, it was possible to model a direct expansion (DX) rack system with multiple refrigerated cases. The basic simulation software handles all the building energy uses, typically on a 5 to 10 minute time step throughout the period of interest. The original refrigeration module included the ability to model the sensible and latent interactions between the refrigerated cases and the building HVAC system, along with some basic heat recovery capabilities. Over the last few years, the refrigeration module has been expanded to handle more complex systems, such as secondary loops, shared condensers, cascade condensers, subcoolers, and walk-in coolers exchanging energy with multiple conditioned zones.

Stovall, Therese K [ORNL; Baxter, Van D [ORNL

2010-01-01T23:59:59.000Z

486

Covered Product Category: Commercial Refrigerators and Freezers...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Beer-dispensing and direct draw units Glass frosters Deep well and bunker freezers. Open-air units, deli cases, prep tables, drawer cabinets, laboratory-grade products,...

487

Optimization of Air Conditioning Cycling  

E-Print Network [OSTI]

Benchmark – Long Cycle .............................................................................................. 95 5.46 System Pressures and Temperatures – Valve Part Cycle Vs Benchmark – Long Cycle...

Seshadri, Swarooph

2012-10-19T23:59:59.000Z

488

Next Generation Rooftop Unit | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Next Generation Rooftop Unit Next Generation Rooftop Unit Next Generation Rooftop Unit The U.S. Department of Energy is currently conducting research in a next generation rooftop unit (RTU). More than half of U.S. commercial building space is cooled by packaged heating, ventilation, and air conditioning (HVAC) equipment. Existing rooftop HVAC units consume more than 1.3% of the United States' annual energy usage annually. Project Description This project seeks to evaluate optimal design strategies for significantly improving the efficiency of rooftop units. The primary market for this project is commercial buildings, such as supermarkets and hotels. Project Partners Research is being undertaken through a cooperative research and development agreement (CRADA) between the Department of Energy and Oak Ridge National

489

Refrigeration Recovery for Experiment Hall High Target Loads  

SciTech Connect (OSTI)

The Qweak experiment at Jefferson Lab (JLab) is a 3000 W hydrogen target scheduled for the summer of 2010 and running for two years until the planned shut-down for 12GeV. The End Station Refrigerator (ESR) supports the three experiment halls, two of which may normally have a hydrogen target. The refrigerator for the ESR is a CTI/Helix 1500 W 4.5-K refrigerator nominally capable of supporting a 1250 W target load at 12 bar and 15-K (plus 1100 W of 4.5-K refrigeration). As such, this refrigerator is not capable of supporting the Qweak experiment target load in its present condition. Additionally, since the installation of an ambient air vaporizer for a single use, two week run duration of a high target load in the summer of 2003 there has been a consistent usage of the Central Helium Liquefier’s (CHL’s) 3 bar 4.5-K helium, supplied via an existing transfer-line to the ESR, for other high target loads. By the fall of 2004, it was apparent that this continued use of CHL’s supercritical helium was routinely being sought by the hall experimenters. As such, a method of refrigeration recovery was proposed to reduce the support required of CHL for these high target loads, including the anticipated Qweak experiment, while utilizing the recovered CHL refrigeration from the target to increase ESR’s 12 bar 15-K capacity.

Peter Knudsen, Venkatarao Ganni, Errol Yuksek, Jonathan Creel

2010-04-01T23:59:59.000Z

490

Effect of parasitic refrigeration on the efficiency of magnetic liquefiers  

SciTech Connect (OSTI)

Our studies have shown that magnetic refrigerators have the potential to liquefy cryogens very efficiently. High efficiency is especially important for liquid hydrogen and natural gas applications where the liquefaction costs are a significant fraction of the total liquid cost. One of the characteristics of magnetic refrigerators is the requirement for a high-field superconducting magnet. Providing a 4.2-K bath for this magnet will require a small amount of parasitic refrigeration at 4.2 K even though the rest of the liquefier may be at 110 K (liquid natural gas) or higher. For several different refrigeration power levels at 4.2 K, we have calculated the efficiency of the magnetic liquefier as a function of power, temperature and the 4.2-K refrigerator efficiency. The results show that if the ratio of the thermal load at 4.2 K to the main refrigerator power is 0.001 or less, the effect on the efficiency of the liquefier is negligible at all temperatures below room temperature provided the 4.2-K refrigerator efficiency is high.

Barclay, J.A.; Stewart, W.F.

1982-01-01T23:59:59.000Z

491

An ammonia refrigerator with an absorption circuit as economizer  

Science Journals Connector (OSTI)

The experimental results of a compression refrigerator with an integrated solution circuit, a so-called compression-absorption cycle, are presented. The compression refrigerator operates with ammonia (NH3) as refrigerant. The cycle is improved by two-stage throttling of the condensate and an absorption circuit which replaces the economizer compressor. The absorption circuit operates on the working pair ammonia/water (NH3/H2O). It is driven by superheat of the compressor without additional heat input from an external source. By this means the benefit of two-stage throttling, namely a reduction in compression work or an increase in refrigeration capacity, can be doubled. In the experiments an improvement of up to 9% in the efficiency of the NH3-refrigeration cycle has been attained. Compared to a simple compression refrigerator, the presented compression-absorption cycle has a payback time of only several months. Compared to a conventional economizer refrigeration cycle, the payback can be expected within the range of several months to about four years.

F Ziegler; U Spindler

1993-01-01T23:59:59.000Z

492

Application Availability of Insulation Heat of the Terrace in a Rebuilt Refrigerator  

E-Print Network [OSTI]

, analyzes the temperature distribution of the terrace, and supplies guidance for rebuilding refrigerators....

Qu, C.; Sun, Y.; Chen, Z.

2006-01-01T23:59:59.000Z

493

Product Refrigerator Freezer Fresh, in shell 4 to 5 weeks Don't freeze  

E-Print Network [OSTI]

Product Refrigerator Freezer Eggs Fresh, in shell 4 to 5 weeks Don't freeze Raw yolks, whites 2 recommended storage times are for quality only. Refrigerator & Freezer Storage Chart Product Refrigerator, opened 3 days Don't freeze unopened 10 days 1 year Mayonnaise, commercial Refrigerate after opening 2

Burke, Peter

494

Removal of submicron particles using a carbon fiber ionizer-assisted medium air filter in a heating, ventilation, and air-conditioning (HVAC) system  

Science Journals Connector (OSTI)

Laboratory tests of particle removal were performed with a pair of carbon fiber ionizers installed upstream of a glass fiber air filter. For air flow face velocities of 0.4, 0.6, and 0.8 m/s, the overall particle removal efficiencies of the filter for all submicron particles were 17%, 16%, and 14%, respectively, when the ionizers were not turned on. These values increased to 27%, 23%, and 19%, respectively, when the ionizers were used to generate ions of 6.0 × 109 ions/cm3 in concentration. The carbon fiber ionizers were then installed in front of a glass fiber air filter located in a heating, ventilation, and air-conditioning (HVAC) system. Field tests were performed in a test office room with a total indoor particle concentration of 2.2 × 104 particles/cm3. When the flow rate was 75 cubic meters per hour (CMH), the steady-state values of the total indoor particle concentrations using the glass fiber air filter with and without ionizers decreased to 0.87 × 104 particles/cm3 and 1.15 × 104 particles/cm3, respectively, resulting in a 25% decrease of the ionizer effect. When the operation flow rate was increased to 115 and 150 CMH, the effect of the ionizer decreased to 19% and 17%, respectively. These experimental data match the results calculated using a mass-balance model whose parameters were determined from laboratory tests.

Jae Hong Park; Ki Young Yoon; Jungho Hwang

2011-01-01T23:59:59.000Z

495

M . B a h r a m i ENSC 388 Experiment 2: Vapor Compression Refrigeration Cycle ENSC 388: Engineering Thermodynamics and Heat Transfer  

E-Print Network [OSTI]

Determining the coefficient of performance of a vapour compression refrigeration cycle. Apparatus Figure 1, a condenser, an evaporator and an expansion valve. The compressor unit shown in Fig. 2 comprises the liquid to vapor. The system has an expansion valve which is a float valve. Schematic of the expansion

Bahrami, Majid

496

Summary Max Total Units  

Broader source: Energy.gov (indexed) [DOE]

Max Total Units Max Total Units *If All Splits, No Rack Units **If Only FW, AC Splits 1000 52 28 28 2000 87 59 35 3000 61 33 15 4000 61 33 15 Totals 261 153 93 ***Costs $1,957,500.00 $1,147,500.00 $697,500.00 Notes: added several refrigerants removed bins from analysis removed R-22 from list 1000lb, no Glycol, CO2 or ammonia Seawater R-404A only * includes seawater units ** no seawater units included *** Costs = (total units) X (estimate of $7500 per unit) 1000lb, air cooled split systems, fresh water Refrig Voltage Cond Unit IF-CU Combos 2 4 5 28 References Refrig Voltage C-U type Compressor HP R-404A 208/1/60 Hermetic SA 2.5 R-507 230/1/60 Hermetic MA 2.5 208/3/60 SemiHerm SA 1.5 230/3/60 SemiHerm MA 1.5 SemiHerm HA 1.5 1000lb, remote rack systems, fresh water Refrig/system Voltage Combos 12 2 24 References Refrig/system Voltage IF only

497

New Regenerative Cycle for Vapor Compression Refrigeration  

Office of Scientific and Technical Information (OSTI)

SCIENTIFIC REPORT SCIENTIFIC REPORT Title Page Project Title: New Regenerative Cycle for Vapor Compression Refrigeration DOE Award Number: DE-FG36-04GO14327 Document Title: Final Scientific Report Period Covered by Report: September 30, 2004 to September 30, 2005 Name and Address of Recipient Organization: Magnetic Development, Inc., 68 Winterhill Road, Madison, CT 06443, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Contact Information: Mark J. Bergander, Ph.D., P.E., Principal Investigator, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Project Objective (as stated in the proposal): The main objective of this project is to confirm on a well-instrumented prototype the theoretically derived claims of higher efficiency and coefficient

498

Simple thermodynamic diagrams for real refrigeration systems  

Science Journals Connector (OSTI)

The thermodynamic performance of real irreversible cooling and refrigeration systems (chillers) can be summarized in simple rectangular temperature-entropy diagrams in analogy to classic pedagogical examples for idealized reversible devices. The key to translating complex dissipative losses into this graphical framework is the process average temperature—a factor that can be calculated from nonintrusive experimental measurements for converting entropy production into lost work. An uncomplicated thermodynamic model is used to transform the governing chiller performance equations into an easily-interpreted graph. Examples based upon actual data from commercial work-driven (reciprocating) and heat-driven (absorption) chillers are presented and are used to highlight the predominance of internal dissipation in determining chiller efficiency. With the thermodynamic diagram representation the relative roles of each irreversibility source as well as the reversible and endoreversible limits become transparent.

J. M. Gordon; K. C. Ng; H. T. Chua

1999-01-01T23:59:59.000Z

499

Isothermally heatsunk diffusion cloud chamber refrigerator  

SciTech Connect (OSTI)

This patent describes a diffusion cloud chamber isothermally heatsunk refrigerator which comprises: a heatsink consisting of two phases of a saturated substance existing in thermodynamic equilibrium at constant pressure and therefore at constant temperature, contained in a reservoir; a means of pressure damping to maintain constant pressure, as the ratio of the two phases present changes and introduces volumetric changes in the substance; a cooling member which transfer heat from vapor in contact with the cooling member surface to the ''cold side'' of a Peltier thermoelectric element with which the cooling member is in thermal contact; a Peltier thermoelectric element which removes the heat supplied by the cooling member from its ''cold side'' and pumps it to the ''hot side'' when driven by an electric current; and a means of transferring heat from the ''hot side'' of the Peltier thermoelectric element to the two-phase isothermal substance in the reservoir.

Menocal, S.G.

1987-05-05T23:59:59.000Z

500

Bipolar pulse field for magnetic refrigeration  

DOE Patents [OSTI]

A magnetic refrigeration apparatus includes first and second