1

Suction muffler for refrigeration compressor  

SciTech Connect

A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell.

Nelson, Richard T. (Worthington, OH); Middleton, Marc G. (West Jefferson, OH)

1983-01-01T23:59:59.000Z

2

Suction muffler for refrigeration compressor  

DOE Patents (OSTI)

A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell. 5 figs.

Nelson, R.T.; Middleton, M.G.

1983-01-25T23:59:59.000Z

3

Condensation of refrigerants on vertical fluted tubes  

DOE Green Energy (OSTI)

Experiments were run to determine heat transfer performance of single vertical fluted tubes with selected fluids condensing on the outside. Working fluids included six fluorocarbons (Refrigerants 11, 21, 22, 113, 114, and 115) and a hydrocarbon (Refrigerant 600a or isobutane). The nine test tubes were of 2.54-cm (1-in.) nominal outside diameter and 1.2 m (4 ft) in length with from 0 (smooth) to 60 axial flutes. Condensing heat transfer coefficients ranged from 620 to 7900 W/m/sup 2/ . K (110 to 1400 Btu/hr . ft/sup 2/ . /sup 0/F) over the heat flux range of 2000 to 43,000 W/m/sup 2/ (920 to 13,600 Btu/hr . ft/sup 2/). All parameters are based on total condensing surface area. The data show that, for a given heat flux, a fluted tube can increase condensing coefficients up to 6.0 times smooth tube values. Further heat transfer enhancement was achieved by the use of drainage skirts on fluted tubes; these skirts effectively divided the 1.2-m (4-ft) tubes into two, four, and eight equal condensing lengths.

Combs, S.K.; Mailen, G.S.; Murphy, R.W.

1978-08-01T23:59:59.000Z

4

New empirical correlations for sizing adiabatic capillary tubes in refrigeration systems  

Science Conference Proceedings (OSTI)

This paper presents new empirical correlations that have been developed for sizing adiabatic capillary tubes used in small vapor compression refrigeration and air-conditioning systems. A numerical model which is based on the basic equations of conservation of mass

S. Shodiya; A. A. Aahar; N. Henry; A. N. Darus

2012-01-01T23:59:59.000Z

5

Refrigerant forced-convection condensation inside horizontal tubes  

E-Print Network (OSTI)

Condensing heat transfer rates inside a horizontal tube were investigated -for large quality changes across the tube. The proposed correlation is a modification of the work of Rohsenow, Webber and Ling [29]. The result of ...

Bae, Soonhoon

1968-01-01T23:59:59.000Z

6

Effect of surface conditions on boiling heat transfer of refrigerants in shell-and-tube evaporators  

Science Conference Proceedings (OSTI)

Experimental results are presented for the boiling heat transfer performance of R 22 and R 717 on surfaces with porous metallized coatings. A calculational-theoretical model is given for predicting the heat transfer of refrigerants boiling on a bundle of finned tubes.

Danilova, G.N.; Dyundin, V.A.; Borishanskaya, A.V.; Soloviyov, A.G.; Vol'nykh, Y.A.; Kozyrev, A.A.

1990-01-01T23:59:59.000Z

7

Refrigerant forced-convection condensation inside horizontal tubes  

E-Print Network (OSTI)

High vapor velocity condensation inside a tube was studied theoretically. The heat transfer coefficients were calculated by the momentum and heat transfer analogy. The Von Karman universal velocity distribution was applied ...

Bae, Soonhoon

1969-01-01T23:59:59.000Z

8

Refrigerant forced-convection condensation inside horizontal tubes  

E-Print Network (OSTI)

High vapor velocity condensation inside a tube was studied theoretically. The heat transfer coefficients were calculated by the momentum and heat transfer analogy. The Von Karman universal velocity distribution was applied ...

Bae, Soonhoon

1970-01-01T23:59:59.000Z

9

Design of a single orifice pulse tube refrigerator through the development of a first-order model  

E-Print Network (OSTI)

A first order model for the behavior of a linear orifice pulse tube refrigerator (OPTR) was developed as a design tool for construction of actual OPTRs. The model predicts cooling power as well as the pressure/volume ...

Schor, Alisha R. (Alisha Robin)

2007-01-01T23:59:59.000Z

10

The Effect of Circuiting Arrangement on the Thermal Performance of Refrigeration Mixtures in Tube-and-Fin Condensing Heat Exchangers  

SciTech Connect

For the pure or azeotropic refrigerants typically used in present air conditioning and refrigeration applications, the refrigerant changes phase at a constant temperature. Thus, the refrigerant circuiting arrangement such as crossfiow, counterfiow, or cross-counterflow, has no effect on the thermal performance. For zeotropic refrigerant mixtures, however, the phase-change occurs over a temperature range, or "glide", and the refrigerant circuiting arrangement, or flow path through the heat exchanger, can affect the thermal performance of both the heat exchangers as well as the overall efficiency of the vapor compression cooling cycle. The effects of tsvo diflerent circuiting arrangements on the thermal performance of a zeotropic retligerant mixture and an almost azeotropic refrigerant mixture in a four-row cross-countertlow heat exchanger arrangement are reported here. The two condensers differ only in the manner of circuiting the refrigerant tubes, where one has refrigerant always flowing downward in the active heat transfer region ("identical order") and the other has refrigerant alternating flow direction in the active heat transfer region ("inverted order"). All other geometric parameters, such as bce are% fin louver geometry, refrigerant tube size and enhancement etc., are the same for both heat exchangers. One refrigerant mixture (R-41OA) un&rgoes a small temperature change ("low glide") during phase change, and the other retligerant mixture (a multi- component proprietary mixture) has a substantial temperature change ("high glide") of approximately 10"C during the phase change process. The overall thermal conductance, two-phase conductance, and pressure drop are presented. For the flow conditions of these tests, which are representative of resi&ntial cooling conditions, inverted order circuiting is more desirable than identical order. The potential thermal advantages of the i&ntical order arrangement for high-glide zeotropic refrigerant mixtures are negated by the increased parasitic refrigerant-side pressure drop utiortunately resulting from tkbrication requirements of the identical order circuiting.

Chen, D.T.; Conklin, J.C.

1999-03-15T23:59:59.000Z

11

Improvement of xenon purification system using a combination of a pulse tube refrigerator and a coaxial heat exchanger  

E-Print Network (OSTI)

We have developed a compact cryogenic system with a pulse tube refrigerator and a coaxial heat exchanger. This liquefaction-purification system not only saves the cooling power used to reach high gaseous recirculation rate, but also reduces the impurity level with high speed. The heat exchanger operates with an efficiency of 99%, which indicates the possibility for fast xenon gas recirculation in a highpressurized large-scale xenon storage with much less thermal losses.

Chen, Wan-Ting; Cussonneau, J -P; Donnard, J; Duval, S; Lemaire, O; Calloch, M Le; Ray, P Le; Mohamad-Hadi, A -F; Morteau, E; Oger, T; Scotto-Lavina, L; Stutzmann, J -S; Thers, D; Briend, P; Haruyama, T; Mihara, S; Tauchi, T

2012-01-01T23:59:59.000Z

12

Refrigerated cryogenic envelope  

DOE Patents (OSTI)

An elongated cryogenic envelope including an outer tube and an inner tube coaxially spaced within said inner tube so that the space therebetween forms a vacuum chamber for holding a vacuum. The inner and outer tubes are provided with means for expanding or contracting during thermal changes. A shield is located in the vacuum chamber intermediate the inner and outer tubes; and, a refrigeration tube for directing refrigeration to the shield is coiled about at least a portion of the inner tube within the vacuum chamber to permit the refrigeration tube to expand or contract along its length during thermal changes within said vacuum chamber.

Loudon, John D. (Boulder, CO)

1976-11-16T23:59:59.000Z

13

Oil cooled, hermetic refrigerant compressor  

DOE Patents (OSTI)

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler and is then delivered through the shell to the top of the motor rotor where most of it is flung radially outwardly within the confined space provided by the cap which channels the flow of most of the oil around the top of the stator and then out to a multiplicity of holes to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator from which the suction gas passes by a confined path in pipe to the suction plenum and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum. 3 figs.

English, W.A.; Young, R.R.

1985-05-14T23:59:59.000Z

14

Oil cooled, hermetic refrigerant compressor  

DOE Patents (OSTI)

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler 18 and is then delivered through the shell to the top of the motor rotor 24 where most of it is flung radially outwardly within the confined space provided by the cap 50 which channels the flow of most of the oil around the top of the stator 26 and then out to a multiplicity of holes 52 to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber 58 to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole 62 also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator 68 from which the suction gas passes by a confined path in pipe 66 to the suction plenum 64 and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum 64.

English, William A. (Murrysville, PA); Young, Robert R. (Murrysville, PA)

1985-01-01T23:59:59.000Z

15

Control method for mixed refrigerant based natural gas liquefier  

DOE Patents (OSTI)

In a natural gas liquefaction system having a refrigerant storage circuit, a refrigerant circulation circuit in fluid communication with the refrigerant storage circuit, and a natural gas liquefaction circuit in thermal communication with the refrigerant circulation circuit, a method for liquefaction of natural gas in which pressure in the refrigerant circulation circuit is adjusted to below about 175 psig by exchange of refrigerant with the refrigerant storage circuit. A variable speed motor is started whereby operation of a compressor is initiated. The compressor is operated at full discharge capacity. Operation of an expansion valve is initiated whereby suction pressure at the suction pressure port of the compressor is maintained below about 30 psig and discharge pressure at the discharge pressure port of the compressor is maintained below about 350 psig. Refrigerant vapor is introduced from the refrigerant holding tank into the refrigerant circulation circuit until the suction pressure is reduced to below about 15 psig, after which flow of the refrigerant vapor from the refrigerant holding tank is terminated. Natural gas is then introduced into a natural gas liquefier, resulting in liquefaction of the natural gas.

Kountz, Kenneth J. (Palatine, IL); Bishop, Patrick M. (Chicago, IL)

2003-01-01T23:59:59.000Z

16

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion  

E-Print Network (OSTI)

The effect of the improper charging on the performance (capacity, EER, power consumption, SEER, and coefficient of degradation) of a residential air conditioner during the steady state (wet and dry coils) and cycling operation was investigated. The fully charged condition was established as a base case. A full charge was obtained charging the unit to the superheat specified by the manufacturer's charging chart for specific set of indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 20%, 15%, 10%, and 5% under and overcharging of refrigerant (by mass). The fully charged tests were compared to under and overcharging. The performance of the unit was evaluated as a function of charge as well as at four outdoor room temperatures (82°F, 90°F, 95°F, and 100°F). As the outdoor temperature increased, the total capacity and EER dropped. The investigation of improper charging showed that the total capacity, EER, and SEER were more sensitive to undercharging than overcharging conditions. A 20% undercharge resulted in a 21% reduction in SEER while a 20% overcharge produced a 11% reduction in SEER. Other data such as refrigerant flow rate, sensible heat ratio, superheat and subcooling are also presented.

Farzad, M.; O'Neal, D. L.

1988-01-01T23:59:59.000Z

17

Monitoring field soil suction using a miniature tensiometer  

E-Print Network (OSTI)

An experimental device was developed to monitor the field soil suction using miniature tensiometer. This device consists of a double tube system that ensures a good contact between the tensiometer and the soil surface at the bottom of the testing borehole. This system also ensures the tensiometer periodical retrieving without disturbing the surrounding soil. This device was used to monitor the soil suction at the site of Boissy-le-Ch\\^atel, France. The measurement was performed at two depths (25 and 45 cm) during two months (May and June 2004). The recorded suction data are analyzed by comparing with the volumetric water content data recorded using TDR (Time Domain Reflectometer) probes as well as the meteorological data. A good agreement between these results was observed, showing a satisfactory performance of the developed device.

Cui, Yu-Jun; Mantho, Altin Theodore; De Laure, Emmanuel

2008-01-01T23:59:59.000Z

18

Frontiers in thermoacoustic refrigeration and mixture separation  

E-Print Network (OSTI)

pulse-tube refrigerator shown in Figure 1 dissipates acoustic power by design because power must flowFrontiers in thermoacoustic refrigeration and mixture separation S. Backhaus1 , D. Geller2 , B oscillating thermodynamics in a gas in a sealed system. Since then, many related engines and refrigerators

19

Solar powered refrigeration apparatus  

SciTech Connect

Solar powered refrigeration apparatus is disclosed in which an absorption refrigeration system is operated directly by solar energy. One end of a heat pipe is thermally connected to the boiler of the absorption refrigeration system, and a solar collector is thermally coupled to the other remote end of the heat pipe. The heat pipe is a sealed, evacuated metal tube partially filled with water. The solar collector is a double walled glass vacuum tube with a central axial opening for accommodating the remote end of the heat pipe. Heat energy collected by the solar collector boils the water in the heat pipe to subsequently condense in the area of the boiler thus transferring heat energy along the heat pipe to the boiler. The heat pipe is installed sloping downwardly away from the boiler to permit the return of condensate down the pipe to the solar collector area thus permitting continuous operation.

Theakston, F.H.

1982-12-07T23:59:59.000Z

20

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

of the tower An (earlier) alternative is to use a spray pond to cool water; disadvantages are a large areaRefrigerationRefrigerationRefrigeration coursecourse # 424503.0# 424503.0 v.v. 20122012 7. Air conditioning, cooling towersg, g Ron Zevenhoven Ã?Ã?bo, is the hi htemperature at which condensation begins when air is cooled at constant pressurecooled

Zevenhoven, Ron

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

refrigeration processes (4 5) Vapor-compression refrigeration processes (4-5) Absorption refrigeration; Gas processing (O2, H2, CO2, LPG, LNG...) (3) Air conditioning, cooling towers, rg/pages/zon Air conditioning, cooling towers, food cooling and freezing (4) Heat pumps, heat pipes, special ww.sgisland.o p p

Zevenhoven, Ron

22

Energy Efficient Operation of Ammonia Refrigeration Systems  

SciTech Connect

Ammonia refrigeration systems typically offer many energy efficiency opportunities because of their size and complexity. This paper develops a model for simulating single-stage ammonia refrigeration systems, describes common energy saving opportunities, and uses the model to quantify those opportunities. The simulation model uses data that are typically available during site visits to ammonia refrigeration plants and can be calibrated to actual consumption and performance data if available. Annual electricity consumption for a base-case ammonia refrigeration system is simulated. The model is then used to quantify energy savings for six specific energy efficiency opportunities; reduce refrigeration load, increase suction pressure, employ dual suction, decrease minimum head pressure set-point, increase evaporative condenser capacity, and reclaim heat. Methods and considerations for achieving each saving opportunity are discussed. The model captures synergistic effects that result when more than one component or parameter is changed. This methodology represents an effective method to model and quantify common energy saving opportunities in ammonia refrigeration systems. The results indicate the range of savings that might be expected from common energy efficiency opportunities.

Mohammed, Abdul Qayyum [University of Dayton, Ohio; Wenning, Thomas J [ORNL; Sever, Franc [University of Dayton, Ohio; Kissock, Professor Kelly [University of Dayton, Ohio

2013-01-01T23:59:59.000Z

23

(DDBS) System Doubles Pot Suction, Reduces Roof Emission  

Science Conference Proceedings (OSTI)

... Suction (DDBS) System Doubles Pot Suction, Reduces Roof Emission .... Phase Change Materials in Thermal Energy Storage for Concentrating Solar Power ...

24

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

.100.110.2 Typical refrigerant: R-134a, R- 600a and other hydrocarbons cture:http://1 Air-cooled condensing unit ncompressioisentropicwithprocess isentropicc realc t COP COP · The diagram gives some efficiency data from commercial vapour- 6 some efficiency data from commercial vapour compression refrigerators (T1 = TH, T2 = TL, data from 1976

Zevenhoven, Ron

25

Status of not-in-kind refrigeration technologies for household space conditioning, water heating and food refrigeration  

Science Conference Proceedings (OSTI)

This paper presents a review of the next generation not-in-kind technologies to replace conventional vapor compression refrigeration technology for household applications. Such technologies are sought to provide energy savings or other environmental benefits for space conditioning, water heating and refrigeration for domestic use. These alternative technologies include: thermoacoustic refrigeration, thermoelectric refrigeration, thermotunneling, magnetic refrigeration, Stirling cycle refrigeration, pulse tube refrigeration, Malone cycle refrigeration, absorption refrigeration, adsorption refrigeration, and compressor driven metal hydride heat pumps. Furthermore, heat pump water heating and integrated heat pump systems are also discussed due to their significant energy saving potential for water heating and space conditioning in households. The paper provides a snapshot of the future R&D needs for each of the technologies along with the associated barriers. Both thermoelectric and magnetic technologies look relatively attractive due to recent developments in the materials and prototypes being manufactured.

Bansal, Pradeep [ORNL; Vineyard, Edward Allan [ORNL; Abdelaziz, Omar [ORNL

2012-01-01T23:59:59.000Z

26

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

) and gives it off at higher ail.asp?article temperature (and pressure) and gives it off at higher temperature or no pressure changes Coolant for an engine: e:http://www 8.11.2012Ã?bo Akademi Univ - Thermal and Flow Engineering - Piispankatu 8, 20500 Turku 32/64 pressure changes. Coolant for an engine: not a refrigerant

Zevenhoven, Ron

27

2173333115 A DESIGN MODEL FOR CAPILLARY TUBE-SUCTION  

E-Print Network (OSTI)

Center was founded in 1988 with a grant from the estate of Richard W. Kritzer, the founder of Peerless of America Inc. A State of Illinois Technology Challenge Grant helped build the laboratory facilities. The ACRC receives continuing support from the Richard W. Kritzer Endowment and the National Science Foundation. Thefollowing organizations have also become sponsors of the Center. Acustar Division of Chrysler Allied-Signal, Inc.

R. A. Peixoto; C. W. Bullard; Air Conditioning; C. W. Bullard; Principal Investigator; The Air Conditioning; Carrier Corporation; U. S. Anny Cerl; R. A. Peixoto; C. W. Bullard

1994-01-01T23:59:59.000Z

28

Refrigerant directly cooled capacitors  

DOE Patents (OSTI)

The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.

Hsu, John S. (Oak Ridge, TN); Seiber, Larry E. (Oak Ridge, TN); Marlino, Laura D. (Oak Ridge, TN); Ayers, Curtis W. (Kingston, TN)

2007-09-11T23:59:59.000Z

29

Fluorescent refrigeration  

DOE Patents (OSTI)

Fluorescent refrigeration is based on selective radiative pumping, using substantially monochromatic radiation, of quantum excitations which are then endothermically redistributed to higher energies. Ultimately, the populated energy levels radiatively deexcite emitting, on the average, more radiant energy than was initially absorbed. The material utilized to accomplish the cooling must have dimensions such that the exciting radiation is strongly absorbed, but the fluorescence may exit the material through a significantly smaller optical pathlength. Optical fibers and mirrored glasses and crystals provide this requirement. 6 figs.

Epstein, R.I.; Edwards, B.C.; Buchwald, M.I.; Gosnell, T.R.

1995-09-05T23:59:59.000Z

30

Remotely operated submersible underwater suction apparatus  

DOE Patents (OSTI)

A completely submersible, remotely operated underwater suction device for collection of irradiated materials in a nuclear pool is disclosed. The device includes a pump means for pumping water through the device, a filter means for capturing irradiated debris, remotely operated releasable connector means, a collection means and a means for remotely maneuvering the collection means. The components of the suction device may be changed and replaced underwater to take advantage of the excellent radiation shielding ability of water to thereby minimize exposure of personnel to radiation.

Kristan, Louis L. (2111 Brentwood Dr., Idaho Falls, ID 83402)

1990-01-01T23:59:59.000Z

31

Literature survey of heat transfer enhancement techniques in refrigeration applications  

Science Conference Proceedings (OSTI)

A survey has been performed of the technical and patent literature on enhanced heat transfer of refrigerants in pool boiling, forced convection evaporation, and condensation. Extensive bibliographies of the technical literature and patents are given. Many passive and active techniques were examined for pure refrigerants, refrigerant-oil mixtures, and refrigerant mixtures. The citations were categorized according to enhancement technique, heat transfer mode, and tube or shell side focus. The effects of the enhancement techniques relative to smooth and/or pure refrigerants were illustrated through the discussion of selected papers. Patented enhancement techniques also are discussed. Enhanced heat transfer has demonstrated significant improvements in performance in many refrigerant applications. However, refrigerant mixtures and refrigerant-oil mixtures have not been studied extensively; no research has been performed with enhanced refrigerant mixtures with oil. Most studies have been of the parametric type; there has been inadequate examination of the fundamental processes governing enhanced refrigerant heat transfer, but some modeling is being done and correlations developed. It is clear that an enhancement technique must be optimized for the refrigerant and operating condition. Fundamental processes governing the heat transfer must be examined if models for enhancement techniques are to be developed; these models could provide the method to optimize a surface. Refrigerant mixtures, with and without oil present, must be studied with enhancement devices; there is too little known to be able to estimate the effects of mixtures (particularly NARMs) with enhanced heat transfer. Other conclusions and recommendations are offered.

Jensen, M.K.; Shome, B. [Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Mechanical Engineering, Aeronautical Engineering and Mechanics

1994-05-01T23:59:59.000Z

32

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M.

1996-07-01T23:59:59.000Z

33

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)] [Calm (James M.), Great Falls, VA (United States)

1999-01-01T23:59:59.000Z

34

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M.

1996-11-15T23:59:59.000Z

35

Spray generators for absorption refrigeration systems  

DOE Patents (OSTI)

A spray generator for an absorption refrigeration system that includes a heat exchanger comprised of a multiplicity of variably spaced heat exchange tubes. The tubes are spaced close together near the top of the heat exchanger and spaced more widely apart near the bottom of the heat exchanger. Dilute absorbent solution is sprayed down through the heat exchanger. The close nesting of the tubes in the top portion of the heat exchanger retards liquid flow and aids heating of the solution. The wide spacing of the tubes in the lower section of the heat exchanger facilitate vapor flow out of the heat exchanger and eliminates liquid "blow-off". The top tubes are covered by a baffle to prevent the liquid solution from splashing out of the heat exchanger off of these top tubes.

Sibley, Howard W. (Baldwinsville, NY)

1979-06-19T23:59:59.000Z

36

ARTI Refrigerant Database  

Science Conference Proceedings (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

1994-05-27T23:59:59.000Z

37

Genetic-based modeling of uplift capacity of suction caissons  

Science Conference Proceedings (OSTI)

In this study, classical tree-based genetic programming (TGP) and its recent variants, namely linear genetic programming (LGP) and gene expression programming (GEP) are utilized to develop new prediction equations for the uplift capacity of suction caissons. ... Keywords: Formulation, Gene expression programming, Linear genetic programming, Standard genetic programming, Suction caissons, Uplift capacity

Amir Hossein Alavi; Pejman Aminian; Amir Hossein Gandomi; Milad Arab Esmaeili

2011-09-01T23:59:59.000Z

38

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

Calm, J.M.

1997-02-01T23:59:59.000Z

39

Regenerator for Magnetic Refrigerants  

Ames Laboratory researchers have developed a new magnetic material that can be used at low temperatures (sub liquid hydrogen) for magnetic refrigerators.

40

China Refrigerator Information Label  

E-Print Network (OSTI)

LBNL-246E China Refrigerator Information Label: Specification Development and Potential Impact Jianhong Cheng China National Institute of Standardization Tomoyuki Sakamoto The Institute of Energy

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-11-24T23:59:59.000Z

42

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer (11) at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer (11) to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator (10) to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing he evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator.

Vobach, Arnold R. (6006 Allentown Dr., Spring, TX 77379)

1987-01-01T23:59:59.000Z

43

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer (11) at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer (11) to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator (10) to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator.

Vobach, Arnold R. (6006 Allentown Dr., Spring, TX 77389)

1987-01-01T23:59:59.000Z

44

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-06-23T23:59:59.000Z

45

ARTI Refrigerant Database  

Science Conference Proceedings (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on R-32, R-123, R-124, R- 125, R-134a, R-141b, R142b, R-143a, R-152a, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses polyalkylene glycol (PAG), ester, and other lubricants. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits.

Calm, J.M.

1992-04-30T23:59:59.000Z

46

Tube support  

Science Conference Proceedings (OSTI)

A tube support for supporting horizontal tubes from an inclined vertical support tube passing between the horizontal tubes. A support button is welded to the vertical support tube. Two clamping bars or plates, the lower edges of one bearing on the support button, are removably bolted to the inclined vertical tube. The clamping bars provide upper and lower surface support for the horizontal tubes.

Mullinax, Jerry L. (Green Township, Summit County, OH)

1988-01-01T23:59:59.000Z

47

Thermoacoustic engines and refrigerators  

SciTech Connect

This report is a transcript of a practice lecture given in preparation for a review lecture on the operation of thermoacoustic engines and refrigerators. The author begins by a brief review of the thermodynamic principles underlying the operation of thermoacoustic engines and refrigerators. Remember from thermodynamics class that there are two kinds of heat engines, the heat engine or the prime mover which produces work from heat, and the refrigerator or heat pump that uses work to pump heat. The device operates between two thermal reservoirs at temperatures T{sub hot} and T{sub cold}. In the heat engine, heat flows into the device from the reservoir at T{sub hot}, produces work, and delivers waste heat into the reservoir at T{sub cold}. In the refrigerator, work flows into the device, lifting heat Q{sub cold} from reservoir at T{sub cold} and rejecting waste heat into the reservoir at T{sub hot}.

Swift, G.

1996-12-31T23:59:59.000Z

48

High temperature refrigerator  

SciTech Connect

A high temperature magnetic refrigerator which uses a Stirling-like cycle in which rotating magnetic working material is heated in zero field and adiabatically magnetized, cooled in high field, then adiabatically demagnetized. During this cycle said working material is in heat exchange with a pumped fluid which absorbs heat from a low temperature heat source and deposits heat in a high temperature reservoir. The magnetic refrigeration cycle operates at an efficiency 70% of Carnot.

Steyert, Jr., William A. (Los Alamos, NM)

1978-01-01T23:59:59.000Z

49

Non-intrusive refrigerant charge indicator - Energy ...  

... -phase refrigerant line section. The measured temperature can be used to determine the refrigerant charge status of an HVAC system, ...

50

Demand Response Opportunities in Industrial Refrigerated Warehouses...  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response Opportunities in Industrial Refrigerated Warehouses in California Title Demand Response Opportunities in Industrial Refrigerated Warehouses in California...

51

Liquid over-feeding refrigeration system and method with integrated accumulator-expander-heat exchanger  

DOE Patents (OSTI)

A refrigeration system is described having a vapor compression cycle utilizing a liquid over-feeding operation with an integrated accumulator-expander-heat exchanger. Hot, high-pressure liquid refrigerant from the condenser passes through one or more lengths of capillary tubing substantially immersed in a pool liquid refrigerant in the accumulator-expander-heat exchanger for simultaneously sub-cooling and expanding the liquid refrigerant while vaporizing liquid refrigerant from the pool for the return thereof to the compressor as saturated vapor. The sub-cooling of the expanded liquid provides for the flow of liquid refrigerant into the evaporator for liquid over-feeding the evaporator and thereby increasing the efficiency of the evaporation cycle. 4 figs.

Mei, V.C.; Chen, F.C.

1997-04-22T23:59:59.000Z

52

Liquid over-feeding refrigeration system and method with integrated accumulator-expander-heat exchanger  

DOE Patents (OSTI)

A refrigeration system having a vapor compression cycle utilizing a liquid over-feeding operation with an integrated accumulator-expander-heat exchanger. Hot, high-pressure liquid refrigerant from the condenser passes through one or more lengths of capillary tubing substantially immersed in a pool liquid refrigerant in the accumulator-expander-heat exchanger for simultaneously sub-cooling and expanding the liquid refrigerant while vaporizing liquid refrigerant from the pool for the return thereof to the compressor as saturated vapor. The sub-cooling of the expanded liquid provides for the flow of liquid refrigerant into the evaporator for liquid over-feeding the evaporator and thereby increasing the efficiency of the evaporation cycle.

Mei, Viung C. (Oak Ridge, TN); Chen, Fang C. (Knoxville, TN)

1997-01-01T23:59:59.000Z

53

ARTI Refrigerant Database  

SciTech Connect

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents to accelerate availability of the information and will be completed or replaced in future updates.

Cain, J.M. (Calm (James M.), Great Falls, VA (United States))

1993-04-30T23:59:59.000Z

54

Proceedings: Commercial Refrigeration Research Workshop  

Science Conference Proceedings (OSTI)

Improving refrigeration systems for commercial use can enhance both utility load factors and supermarket profits. This workshop has pinpointed research needs in commercial refrigeration and systems integration for a supermarket environment.

1984-10-01T23:59:59.000Z

55

Japanese refrigerators field testing  

SciTech Connect

Residential refrigerators consume the equivalent of 1700 megawatts (MW) of baseload power in the Bonneville Power Administration (BPA) service area. Japanese manufacturers have designed refrigerator units that appear more energy efficient than some currently available American models. This report summarizes preliminary findings from field testing of 12 refrigerators of Japanese manufacture to evaluate annual kilowatt hour (kWh) use during actual operation. The units have also undergone laboratory testing sponsored by BPA at ETL Testing Laboratories, Inc. in Cortland, New York. A final report of the project -- due at the end of 1989 -- will correlate in detail the results of field and laboratory tests in comparison to performance ratings determined by the manufacturer.

Lou, A.T.

1989-03-01T23:59:59.000Z

56

Adsorption Refrigeration System  

SciTech Connect

Adsorption refrigeration is an environmentally friendly cooling technology which could be driven by recovered waste heat or low-grade heat such as solar energy. In comparison with absorption system, an adsorption system has no problems such as corrosion at high temperature and salt crystallization. In comparison with vapor compression refrigeration system, it has the advantages of simple control, no moving parts and less noise. This paper introduces the basic theory of adsorption cycle as well as the advanced adsorption cycles such as heat and mass recovery cycle, thermal wave cycle and convection thermal wave cycle. The types, characteristics, advantages and drawbacks of different adsorbents used in adsorption refrigeration systems are also summarized. This article will increase the awareness of this emerging cooling technology among the HVAC engineers and help them select appropriate adsorption systems in energy-efficient building design.

Wang, Kai [ORNL; Vineyard, Edward Allan [ORNL

2011-01-01T23:59:59.000Z

57

Japanese Refrigerators Field Testing.  

SciTech Connect

Residential refrigerators consume the equivalent of 1700 megawatts (MW) of baseload power in the Bonneville Power Administration (BPA) service area. Japanese manufacturers have designed refrigerator units that appear more energy efficient than some currently available American models. This report summarizes preliminary findings from field testing of 12 refrigerators of Japanese manufacture to evaluate annual kilowatt hour (kWh) use during actual operation. The units have also undergone laboratory testing sponsored by BPA at ETL Testing Laboratories, Inc. in Cortland, New York. A final report of the project -- due at the end of 1989 -- will correlate in detail the results of field and laboratory tests in comparison to performance ratings determined by the manufacturer.

Lou, Albert T.

1989-03-01T23:59:59.000Z

58

ARTI Refrigerant Database  

Science Conference Proceedings (OSTI)

The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R- 717 (ammonia), ethers, and others as well as azeotropic and zeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents on compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. A computerized version is available that includes retrieval software.

Calm, J.M.

1992-11-09T23:59:59.000Z

59

COLD STORAGE DESIGN REFRIGERATION EQUIPMENT  

E-Print Network (OSTI)

COLD STORAGE DESIGN AND REFRIGERATION EQUIPMENT REFRIGERATION OF FISH - PART 1 \\ "..\\- ,,, T I Fishery Leaflet 427 Washington 25, D. C. June 1956 REFRIGERATION OF FISH - PART em; COlD STORAGE DESIGN · · · · · 18 Specific design features 0 0 · · · · · · · · · · · · · · 19 Refrigerated surfaces 0 · · 0 0 0 · 0

60

Refrigerator recycling and CFCs  

SciTech Connect

Utility-sponsored refrigerator and freezer pick-up programs have removed almost 900,000 inefficient appliances from the North American electric grid to date. While the CFC-12 refrigerant from the discarded appliances is typically removed and recycled, in all but a few programs the CFC-11 in the foam insulation is not. About a quarter-billion pounds of CFC-11 are banked in refrigerator foam in the United States. Release of this ``bank`` of CFC, combined with that from foam insulation used in buildings, will be the largest source of future emissions if preventive measures are not taken. Methods exist to recover the CFC for reuse or to destroy it by incineration. The task of recycling or destroying the CFCs and other materials from millions of refrigerators is a daunting challenge, but one in which utilities can play a leadership role. E Source believes that utilities can profitably serve as the catalyst for public-private partnerships that deliver comprehensive refrigerator recycling. Rather than treating such efforts solely as a DSM resource acquisition, utilities could position these programs as a multifaceted service delivery that offers convenient appliance removal for homeowners, a solid waste minimization service for landfills, a source of recycled materials for industry, and a CFC recovery and/or disposal service in support of the HVAC industry and society`s atmospheric protection goals and laws. Financial mechanisms could be developed through these public-private enterprises to ensure that utilities are compensated for the extra cost of fully recycling refrigerators, including the foam CFC.

Shepard, M.; Hawthorne, W.; Wilson, A.

1994-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Low-temperature magnetic refrigerator  

DOE Patents (OSTI)

The invention relates to magnetic refrigeration and more particularly to low temperature refrigeration between about 4 and about 20 K, with an apparatus and method utilizing a belt of magnetic material passed in and out of a magnetic field with heat exchangers within and outside the field operably disposed to accomplish refrigeration.

Barclay, J.A.

1983-05-26T23:59:59.000Z

62

Compressor performance at high suction temperatures with application to solar heat pump  

DOE Green Energy (OSTI)

As part of the study of Solar Assisted Heat Pump (SAHP) Systems, the performance of the heat pump itself and its components under conditions attendant to series solar input to the evaporator is being investigated at Brookhaven National Laboratory (BNL). Particular emphasis has been placed on the details of the compressor performance, since in order to properly exploit the thermodynamic potential of high solar input temperatures (40 to 100/sup 0/F), the compressor must operate efficiently over a wide range of (saturated) suction temperatures most of which are well above those for which present compressors are designed. A systematic series of experiments is being conducted at evaporating temperatures in the range from 45 to 100/sup 0/F using a Solar Heat Pump Simulator and a specially designed Laboratory Model Heat Pump assembled from off-the-shelf components. Two reciprocating compressors have been tested thus far - an open type driven by a 2-speed motor and a hermetic 2-speed, the multi-speed feature providing capacity control, which is a virtual necessity for effective use of solar source. Thorough and highly accurate instrumentation is used in the simulator and in the heat pump refrigeration loop. The results to date of the compressor aspects of the solar heat pump experiments at BNL are described, and the general application of heat pumps and their compressors to use with solar input are discussed.

Kush, E A

1980-01-01T23:59:59.000Z

63

TUBE TESTER  

DOE Patents (OSTI)

This patent relates to tube testing, and in particular describes a tube tester for automatic testing of a number of vacuum tubes while in service and as frequently as may be desired. In it broadest aspects the tube tester compares a particular tube with a standard tube tarough a difference amplifier. An unbalanced condition in the circuit of the latter produced by excessive deviation of the tube in its characteristics from standard actuates a switch mechanism stopping the testing cycle and indicating the defective tube.

Gittings, H.T. Jr.; Kalbach, J.F.

1958-01-14T23:59:59.000Z

64

Compact acoustic refrigerator  

DOE Patents (OSTI)

This invention is comprised of a compact acoustic refrigeration system that actively cools components, e.g., electrical circuits, in a borehole environment. An acoustic engine includes first thermodynamic elements for generating a standing acoustic wave in a selected medium. An acoustic refrigerator includes second thermodynamic elements located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements and a relatively hot temperature at a second end of the second thermodynamic elements. A resonator volume cooperates with the first and second thermodynamic elements to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements, first heat pipes transfer heat from the heat load to the second thermodynamic elements and second heat pipes transfer heat from first and second thermodynamic elements to the borehole environment.

Bennett, G.A.

1991-12-31T23:59:59.000Z

65

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

This invention is comprised of a cryogenic refrigerator which cools a heat source by cyclically concentrating and diluting the amount of [sup 3]He in a single phase [sup 3]He/[sup 4]He solution. The [sup 3]He in superfluid [sup 4]He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid [sup 3]He at an initial concentration in superfluid [sup 4]He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of [sup 4]He while restricting passage of [sup 3]He. The [sup 3]He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

Swift, G.W.; Kotsubo, V.Y.

1991-04-02T23:59:59.000Z

66

Compact acoustic refrigerator  

DOE Patents (OSTI)

A compact acoustic refrigeration system actively cools components, e.g., electrical circuits, in a borehole environment. An acoustic engine includes first thermodynamic elements for generating a standing acoustic wave in a selected medium. An acoustic refrigerator includes second thermodynamic elements located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements and a relatively hot temperature at a second end of the second thermodynamic elements. A resonator volume cooperates with the first and second thermodynamic elements to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements, first heat pipes transfer heat from the heat load to the second thermodynamic elements and second heat pipes transfer heat from first and second thermodynamic elements to the borehole environment. 18 figs.

Bennett, G.A.

1992-11-24T23:59:59.000Z

67

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of [sup 3]He in a single phase [sup 3]He-[sup 4]He solution. The [sup 3]He in superfluid [sup 4]He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid [sup 3]He at an initial concentration in superfluid [sup 4]He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of [sup 4]He while restricting passage of [sup 3]He. The [sup 3]He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K. 12 figs.

Swift, G.W.; Kotsubo, V.Y.

1992-12-22T23:59:59.000Z

68

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

This invention is comprised of a cryogenic refrigerator which cools a heat source by cyclically concentrating and diluting the amount of {sup 3}He in a single phase {sup 3}He/{sup 4}He solution. The {sup 3}He in superfluid {sup 4}He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid {sup 3}He at an initial concentration in superfluid {sup 4}He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of {sup 4}He while restricting passage of {sup 3}He. The {sup 3}He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

Swift, G.W.; Kotsubo, V.Y.

1991-04-02T23:59:59.000Z

69

Compact acoustic refrigerator  

DOE Patents (OSTI)

A compact acoustic refrigeration system actively cools components, e.g., electrical circuits (22), in a borehole environment. An acoustic engine (12, 14) includes first thermodynamic elements (12) for generating a standing acoustic wave in a selected medium. An acoustic refrigerator (16, 26, 28) includes second thermodynamic elements (16) located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements (16) and a relatively hot temperature at a second end of the second thermodynamic elements (16). A resonator volume (18) cooperates with the first and second thermodynamic elements (12, 16) to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements (12, 16), first heat pipes (24, 26) transfer heat from the heat load (22) to the second thermodynamic elements (16) and second heat pipes (28, 32) transfer heat from first and second thermodynamic elements (12, 16) to the borehole environment.

Bennett, Gloria A. (Los Alamos, NM)

1992-01-01T23:59:59.000Z

70

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of .sup.3 He in a single phase .sup.3 He-.sup.4 He solution. The .sup.3 He in superfluid .sup.4 He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid .sup.3 He at an initial concentration in superfluid .sup.4 He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of .sup.4 He while restricting passage of .sup.3 He. The .sup.3 He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

Swift, Gregory W. (Santa Fe, NM); Kotsubo, Vincent Y. (La Canada, CA)

1992-01-01T23:59:59.000Z

71

Multilayer Thermionic Refrigeration  

DOE Green Energy (OSTI)

A review is presented of our program to construct an efficient solid state refrigerator based on thermionic emission of electrons over periodic barriers in the solid. The experimental program is to construct a simple device with one barrier layer using a three layers: metal-semiconductor-metal. The theoretical program is doing calculations to determine: (i) the optimal layer thickness, and (ii) the thermal conductivity.

Mahan, G.D.

1999-08-30T23:59:59.000Z

72

Vaccine refrigerator testing. Final report  

SciTech Connect

For the Central American Health Clinic Project initiated in 1986, Sandia National Laboratories and the Florida Solar Energy Center recognized the need for a test and evaluation program for vaccine refrigeration systems. At the Florida Solar Energy Center, side-by-side testing of three photovoltaic powered vaccine refrigerators began in 1987. The testing was expanded in 1988 to include a kerosene absorption refrigerator. This report presents observations, conclusions, and recommendations derived from testing the four vaccine refrigeration systems. Information is presented pertaining to the refrigerators, photovoltaic arrays, battery subsystems, charge controllers, and user requirements. This report should be of interest to designers, manufacturers, installers, and users of photovoltaic-powered vaccine refrigeration systems and components.

Ventre, G.G. [Univ. of Central Florida, Orlando, FL (United States); Kilfoyle, D.; Marion, B. [Florida Solar Energy Center, Cape Canaveral, FL (United States)

1990-06-01T23:59:59.000Z

73

Intermittent patient suction system, self-contained control  

DOE Patents (OSTI)

An intermittent patient suction system, a self-contained control device therefor and methods of making the same are provided, the self-contained control device having a housing that contains two restrictor units therein for respectively controlling the "on" time and "off" time that the control device applies a vacuum and does not apply a vacuum through the output of the control device to the patient.

Lewis, Jay L. (Knoxville, TN)

1992-01-01T23:59:59.000Z

74

Magnetic Refrigeration - Programmaster.org  

Science Conference Proceedings (OSTI)

Aug 6, 2013 ... Magnetic Refrigeration a 21st Century Highly Efficient and Green Cooling .... In order to advance their incorporation in prototypes and industrial ...

75

NICE3: Industrial Refrigeration System  

SciTech Connect

Energy Concepts has developed an absorption-augmented system as a cost-effective means of achieving more cooling capacity with a substantial reduction in energy consumption and greenhouse gas emissions for industrial refrigeration. It cuts fuel consumption by 30% by combining an internal combustion engine with a mechanical compression refrigeration system and an absorption refrigeration system. The absorption system is powered by engine waste heat. Conventional industrial refrigeration uses mechanical vapor compression, powered by electric motors, which results in higher energy costs. By the year 2010, the new system could cut fuel consumption by 19 trillion Btu and greenhouse emissions by more than 1 million tons per year.

Simon, P.

1999-09-29T23:59:59.000Z

76

Enhanced shell-and-tube heat eschangers for the power and process industries. Final report  

SciTech Connect

Single-tube pool boiling tests were performed with saturated pure refrigerants and binary mixtures of refrigerants. Generally, with pure refrigerants, the High Flux surface performed better at the higher heat fluxes compared to the Turbo-B tube, and both enhanced surfaces performed significantly better than smooth surface. In tests of R-11/R-113 mixtures, the enhanced surfaces had much less degradation in heat transfer coefficient due to mixture effects compared to smooth tubes; the largest degradation occurred at a mixture of 25% R-11/75% R-113. Under boiling in saturated aqueous solution of calcium sulfate, with a single tube, effects of fouling were more pronounced at the higher heat fluxes for all surfaces. Two staggered tube bundles were tested with tube pitch-diameter ratios of 1.17 and 1.50. For the pure refrigerant, tests on the smooth-tube bundle indicated that the effects on the heat transfer coefficient of varying mass flux, quality, and tube-bundle geometry were small, except at low heat fluxes. Neither enhanced surface showed any effect with changing mass flux or quality. The binary mixture bundle-boiling tests had results that were very similar to those obtained with the pure refrigerants. When boiling a refrigerant-oil mixture, all three surfaces (smooth, High Flux, and Turbo-B) experienced a degradation in its heat transfer coefficient; no surface studied was found to be immune or vulnerable to the presence of oil than another surface.

Bergles, A.E.; Jensen, M.K.; Somerscales, E.F.; Curcio, L.A. Jr.; Trewin, R.R.

1994-08-01T23:59:59.000Z

77

Commercial Refrigeration Equipment | Open Energy Information  

Open Energy Info (EERE)

Refrigeration Equipment Jump to: navigation, search TODO: Add description List of Commercial Refrigeration Equipment Incentives Retrieved from "http:en.openei.orgw...

78

Tube Forming  

Science Conference Proceedings (OSTI)

...The rear-axle housing shown in Fig. 19 was produced from 1035 steel tubing in seven manufacturing operations.

79

Helium dilution refrigeration system  

DOE Patents (OSTI)

A helium dilution refrigeration system operable over a limited time period, and recyclable for a next period of operation is disclosed. The refrigeration system is compact with a self-contained pumping system and heaters for operation of the system. A mixing chamber contains [sup 3]He and [sup 4]He liquids which are precooled by a coupled container containing [sup 3]He liquid, enabling the phase separation of a [sup 3]He rich liquid phase from a dilute [sup 3]He-[sup 4]He liquid phase which leads to the final stage of a dilution cooling process for obtaining low temperatures. The mixing chamber and a still are coupled by a fluid line and are maintained at substantially the same level with the still cross sectional area being smaller than that of the mixing chamber. This configuration provides maximum cooling power and efficiency by the cooling period ending when the [sup 3]He liquid is depleted from the mixing chamber with the mixing chamber nearly empty of liquid helium, thus avoiding unnecessary and inefficient cooling of a large amount of the dilute [sup 3]He-[sup 4]He liquid phase. 2 figs.

Roach, P.R.; Gray, K.E.

1988-09-13T23:59:59.000Z

80

Operation of the Tevatron satellite refrigerators for. 75- and 2. 0-kilometer-long magnet strings  

SciTech Connect

The Tevatron magnets at Fermilab are cooled by a hybrid system which consists of a 5000 liters/hr central helium liquefier coupled with a small-diameter liquid transfer line connecting twenty-four satellite refrigerators. The transfer line supplies liquid helium for both the refrigerators and the magnet lead flow as well as liquid nitrogen for the magnet shields. The satellites act as amplifiers with a gain of twelve by using the enthalpy of the helium supplied by the central liquefier as liquid and converting it to 4.5-K refrigeration and then returning it as 300-K gas. This arrangement combines the advantages of a single central facility with those of individual stand-alone units stationed around the ring. The central liquefier has the high efficiency associated with large components but its requirements for distribution of both cryogenic liquids and electric power to the service buildings is reduced. The six compressor buildings supply 20 atm helium to the twenty-four refrigerators through a discharge header located on the berm and a suction header located in the tunnel. The compressor buildings each have four-two stage 58 g/sec screw compressors; each of these has its own oil removal system. The inventory in the ring is controlled at the first compressor building through a cross-connect line to the central liquefier. The suction header is also used as the cooldown line as well as for quench relief. A third header located in the tunnel is the nitrogen collection and relief header.

Rode, C.H.; Andrews, R.A.; Ferry, R.; Gannon, J.; Makara, J.; Martin, M.; Misek, J.; Peterson, T.; Theilacker, J.

1983-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Cryogenic refrigeration apparatus  

DOE Patents (OSTI)

A technique for producing a cold environment in a refrigerant system in which input fluid from a compressor at a first temperature is introduced into an input channel of the system and is pre-cooled to a second temperature for supply to one of at least two stages of the system, and to a third temperature for supply to another stage thereof. The temperatures at such stages are reduced to fourth and fifth temperatures below the second and third temperatures, respectively. Fluid at the fourth temperature from the one stage is returned through the input channel to the compressor and fluid at the fifth temperature from the other stage is returned to the compressor through an output channel so that pre-cooling of the input fluid to the one stage occurs by regenerative cooling and counterflow cooling and pre-cooling of the input fluid to the other stage occurs primarily by counterflow cooling.

Crunkleton, James A. (Cambridge, MA)

1992-01-01T23:59:59.000Z

82

Cryogenic refrigeration apparatus  

DOE Patents (OSTI)

A technique for producing a cold environment in a refrigerant system in which input fluid from a compressor at a first temperature is introduced into an input channel of the system and is pre-cooled to a second temperature for supply to one of at least two stages of the system, and to a third temperature for supply to another stage thereof. The temperatures at such stages are reduced to fourth and fifth temperatures below the second and third temperatures, respectively. Fluid at the fourth temperature from the one stage is returned through the input channel to the compressor and fluid at the fifth temperature from the other stage is returned to the compressor through an output channel so that pre-cooling of the input fluid to the one stage occurs by regenerative cooling and counterflow cooling and pre-cooling of the input fluid to the other stage occurs primarily by counterflow cooling. 6 figs.

Crunkleton, J.A.

1992-03-31T23:59:59.000Z

83

The Quantum Absorption Refrigerator  

E-Print Network (OSTI)

A quantum absorption refrigerator driven by noise is studied with the purpose of determining the limitations of cooling to absolute zero. The model consists of a working medium coupled simultaneously to hot, cold and noise baths. Explicit expressions for the cooling power are obtained for Gaussian and Poisson white noise. The quantum model is consistent with the first and second laws of thermodynamics. The third law is quantified, the cooling power J_c vanishes as J_c proportional to T_c^{alpha}, when T_c approach 0, where alpha =d+1 for dissipation by emission and absorption of quanta described by a linear coupling to a thermal bosonic field, where d is the dimension of the bath.

Amikam Levy; Ronnie Kosloff

2011-09-04T23:59:59.000Z

84

Magnetic refrigeration apparatus and method  

SciTech Connect

The disclosure relates to refrigeration through magnetizing and demagnitizing a body by rotating it within a magnetic field. Internal and external heat exchange fluids and in one embodiment, a regenerator, are used.

Barclay, John A. (Los Alamos, NM); Overton, Jr., William C. (Los Alamos, NM); Stewart, Walter F. (Los Alamos, NM)

1984-01-01T23:59:59.000Z

85

Pool boiling of R-114/oil mixtures from single tubes and tube bundles. Master's thesis  

Science Conference Proceedings (OSTI)

An apparatus was designed, fabricated, and operated for the testing of horizontal tube bundles for boiling of R-114 with various concentrations of oil. Preliminary data were taken on the top tube in the bundle, with and without the other tubes in operation. Results showed up to a 37% increase in the boiling heat-transfer coefficient as a result of the favorable bundle effect. In a separate single-tube apparatus, three enhanced tubes were tested at a saturation temperature of 2.2 C with oil mass concentrations of 0, 1, 2, 3, 6 and 10%. The tubes were: 1) a finned tube with 1024 fins per meter, 2) a finned tube with 1575 fins per meter and 3) a Turbo-B tube. These tubes resulted in enhancement ratios in pure refrigerant of 2.8, 3.8 and 5.2, respectively, at a practical heat flux of 30 kW/sq. meter. With 3% oil, these ratios were decreased to 2.6, 3.5 and 5, while with 10% oil, these ratios were further reduced to 2.6, 3.2 and 4.7, respectively. Based on these results, the use of Turbo-B tubes is expected to result in significant savings in weight and size of evaporators over the finned tubes presently in use on board some naval vessels.

Murphy, T.J.

1987-09-01T23:59:59.000Z

86

Pressure Tubes  

Science Conference Proceedings (OSTI)

Table 8   Specifications for carbon and alloy steel pressure tubes (ASTM)...medium-strength carbon-molybdenum alloy

87

IMPACTS OF REFRIGERANTLINE LENGTH ON SYSTEM EFFICIENCY IN RESIDENTIAL HEATING AND COOLING SYSTEMS USING REFRIGERANT DISTRIBUTION.  

Science Conference Proceedings (OSTI)

The effects on system efficiency of excess refrigerant line length are calculated for an idealized residential heating and cooling system. By excess line length is meant refrigerant tubing in excess of the 25 R provided for in standard equipment efficiency test methods. The purpose of the calculation is to provide input for a proposed method for evaluating refrigerant distribution system efficiency. A refrigerant distribution system uses refrigerant (instead of ducts or pipes) to carry heat and/or cooling effect from the equipment to the spaces in the building in which it is used. Such systems would include so-called mini-splits as well as more conventional split systems that for one reason or another have the indoor and outdoor coils separated by more than 25 ft. This report performs first-order calculations of the effects on system efficiency, in both the heating and cooling modes, of pressure drops within the refrigerant lines and of heat transfer between the refrigerant lines and the space surrounding them.

ANDREWS, J.W.

2001-04-01T23:59:59.000Z

88

Development of the Pulse Tube Refrigerator as an Efficient ...  

Science Conference Proceedings (OSTI)

... and cryosurgery ! Transportation 1. LNG for fleet vehicles 2. Superconducting magnets in maglev trains ! Energy 1. LNG ...

2001-02-22T23:59:59.000Z

89

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

Page 1. Thermal Analysis of Refrigeration Systems Used for Vaccine Storage ... Suitability of commercial refrigerators for vaccine storage not ...

2012-08-03T23:59:59.000Z

90

COMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATION SYSTEMS  

E-Print Network (OSTI)

One Stage Compressor Heat Exchanger Refrigeration Load XBLOne Stage Compressor Heat Exchanger Refrigeration Load XBLcondensers, surface heat exchangers, surface condensers,

green, M.A.

2011-01-01T23:59:59.000Z

91

Superinsulation in refrigerators and freezers  

SciTech Connect

The results presented here were obtained during Phase 4 of the first CRADA, which had the specific objective of determining the lifetime of superinsulations when installed in simulated refrigerator doors. The second CRADA was established to evaluate and test design concepts proposed to significantly reduce energy consumption in a refrigerator-freezer that is representative of approximately 60% of the US market. The stated goal of this CRADA is to demonstrate advanced technologies which reduce, by 50%, the 1993 National Appliance Energy Conservation Act (NAECA) standard energy consumption for a 20 ft{sup 3} (570 L) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translates to an energy consumption of 1.003 kWh/d. The general objective of the research is to facilitate the introduction of efficient appliances by demonstrating design changes that can be effectively incorporated into new products. In previous work on this project, a Phase 1 prototype refrigerator-freezer achieved an energy consumption of 1.413 kWh/d [Vineyard, et al., 1995]. Following discussions with an advisory group comprised of all the major refrigerator-freezer manufacturers, several options were considered for the Phase 2 effort, one of which was cabinet heat load reductions.

Vineyard, E.; Stovall, T.K.; Wilkes, K.E.; Childs, K.W.

1998-02-01T23:59:59.000Z

92

International Refrigeration: Order (2012-CE-1510)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered International Refrigeration Products to pay an $8,000 civil penalty after finding International Refrigeration had failed to certify that certain room air conditioners comply with the applicable energy conservation standard.

93

Cospolich Refrigerator: Order (2013-CE-5314)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered Cospolich Refrigerator Co, Inc. to pay a $8,000 civil penalty after finding Cospolich Refrigerator had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

94

Thermoelectric refrigerator having improved temperature stabilization means  

DOE Patents (OSTI)

A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature, but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized.

Falco, Charles M. (Woodridge, IL)

1982-01-01T23:59:59.000Z

95

DOE Proposes Higher Efficiency Standards for Refrigerators  

Energy.gov (U.S. Department of Energy (DOE))

New Proposed Standards for Residential Refrigerators and Freezers to Lower Energy Use by as much as Twenty-Five Percent

96

Magnetocaloric Effect and Enhanced Refrigeration effectiveness in ...  

Science Conference Proceedings (OSTI)

Presentation Title, Magnetocaloric Effect and Enhanced Refrigeration effectiveness in ... Industrial Needs and Applications for Soft Magnetic Materials · Industrial ...

97

Optimization of the Refrigerant Capacity in Multiphase ...  

Science Conference Proceedings (OSTI)

Symposium, Magnetic Materials for Energy Applications. Presentation Title, Optimization of the Refrigerant Capacity in Multiphase Magnetocaloric Materials.

98

Bubble Pump Design for Single Pressure Absorption Refrigeration Cycles  

E-Print Network (OSTI)

A model has been developed for the design and optimization of a small bubble pump to be used in a single pressure absorption refrigeration cycle to lift the working fluid mixture against gravity and overcome flow friction. This analytical model is developed from two-phase flow fundamentals and incorporates the design parameters of the bubble pump. Parametric studies are carried out and a design optimization for maximum efficiency is performed for various operating conditions. Optimum efficiency is defined as the liquid pumped per unit of bubble pump heat input. The results show the optimum bubble pump tube diameter over a range of operating conditions.

Sam V. Shelton; Susan White Stewart

2002-01-01T23:59:59.000Z

99

Wheel-type magnetic refrigerator  

DOE Patents (OSTI)

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load.

Barclay, John A. (Los Alamos, NM)

1983-01-01T23:59:59.000Z

100

Wheel-type magnetic refrigerator  

DOE Patents (OSTI)

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load.

Barclay, J.A.

1982-01-20T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Wheel-type magnetic refrigerator  

DOE Patents (OSTI)

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load. 7 figs.

Barclay, J.A.

1983-10-11T23:59:59.000Z

102

Protective tubes for sodium heated water tubes  

DOE Patents (OSTI)

A heat exchanger in which water tubes are heated by liquid sodium which minimizes the results of accidental contact between the water and the sodium caused by failure of one or more of the water tubes. A cylindrical protective tube envelopes each water tube and the sodium flows axially in the annular spaces between the protective tubes and the water tubes.

Essebaggers, Jan (39 Honeyman Dr., Succasunna, NJ 07876)

1979-01-01T23:59:59.000Z

103

Ternary Dy-Er-Al magnetic refrigerants  

DOE Patents (OSTI)

A ternary magnetic refrigerant material comprising (Dy{sub 1{minus}x}Er{sub x})Al{sub 2} for a magnetic refrigerator using the Joule-Brayton thermodynamic cycle spanning a temperature range from about 60K to about 10K, which can be adjusted by changing the Dy to Er ratio of the refrigerant. 29 figs.

Gschneidner, K.A. Jr.; Takeya, Hiroyuki

1995-07-25T23:59:59.000Z

104

Method and apparatus for desuperheating refrigerant  

DOE Patents (OSTI)

The present invention is an apparatus and method for de-superheating a primary refrigerant leaving a compressor wherein a secondary refrigerant is used between the primary refrigerant to be de-superheated. Reject heat is advantageously used for heat reclaim.

Zess, James A. (Kelso, WA); Drost, M. Kevin (Richland, WA); Call, Charles J. (Richland, WA)

1997-01-01T23:59:59.000Z

105

Ternary Dy-Er-Al magnetic refrigerants  

DOE Patents (OSTI)

A ternary magnetic refrigerant material comprising (Dy.sub.1-x Er.sub.x)Al.sub.2 for a magnetic refrigerator using the Joule-Brayton thermodynamic cycle spanning a temperature range from about 60K to about 10K, which can be adjusted by changing the Dy to Er ratio of the refrigerant.

Gschneidner, Jr., Karl A. (Ames, IA); Takeya, Hiroyuki (Ibaraki, JP)

1995-07-25T23:59:59.000Z

106

Investigation of Chlorine-Free Refrigerants for Low-Temperature Supermarket Refrigeration  

Science Conference Proceedings (OSTI)

With the phaseout of chlorofluorocarbon (CFC) refrigerants, supermarkets are seeking a replacement for R-502, the refrigerant of choice for low-temperature (frozen food) refrigeration. EPRI has conducted field testing to characterize the performance of the new hydrofluorocarbon (HFC) nonchlorinated refrigerants replacements for R-502. Results showed that energy and demand savings can be obtained using these alternative refrigerants with zero ozone-depleting potential.

1996-08-10T23:59:59.000Z

107

OPTIMAL DESIGN AND OPERATION OF HELIUM REFRIGERATION SYSTEMS USING THE GANNI CYCLE  

SciTech Connect

The constant pressure ratio process, as implemented in the floating pressure - Ganni cycle, is a new variation to prior cryogenic refrigeration and liquefaction cycle designs that allows for optimal operation and design of helium refrigeration systems. This cycle is based upon the traditional equipment used for helium refrigeration system designs, i.e., constant volume displacement compression and critical flow expansion devices. It takes advantage of the fact that for a given load, the expander sets the compressor discharge pressure and the compressor sets its own suction pressure. This cycle not only provides an essentially constant system Carnot efficiency over a wide load range, but invalidates the traditional philosophy that the (‘TS’) design condition is the optimal operating condition for a given load using the as-built hardware. As such, the Floating Pressure- Ganni Cycle is a solution to reduce the energy consumption while increasing the reliability, flexibility and stability of these systems over a wide operating range and different operating modes and is applicable to most of the existing plants. This paper explains the basic theory behind this cycle operation and contrasts it to the traditional operational philosophies presently used.

Venkatarao Ganni, Peter Knudsen

2010-04-01T23:59:59.000Z

108

Multiple tube premixing device  

SciTech Connect

The present application provides a premixer for a combustor. The premixer may include a fuel plenum with a number of fuel tubes and a burner tube with a number of air tubes. The fuel tubes extend about the air tubes.

Uhm, Jong Ho; Varatharajan, Balachandar; Ziminsky, Willy Steve; Kraemer, Gilbert Otto; Yilmaz, Ertan; Lacy, Benjamin; Stevenson, Christian; Felling, David

2012-12-11T23:59:59.000Z

109

A suction lysimeter and a geophysical access port  

DOE Patents (OSTI)

A sampling apparatus is described for monitoring vadose zones, geologic media or buried waste in sediment and more particularly to such an apparatus which is operable as an access port for geophysical logging and collecting fluid samples to permit analysis of such fluid samples for the presence of toxic substances, having a pipe-like, stainless steel, longitudinally extending, access tube with two ends, where the first end extends above the surface of the sediment and has a removable air tight seal. The subject invention further has a backing in fluid communication with the access tube and a fluid permeable plate contiguous with the backing, wherein the fluid permeable plate is made up of porous stainless steel. A reservoir is integrated into the second closed end of the access tube for containing the collected fluid. A vacuum pump, having a vacuum gauge/transducer attached thereto, is connected to the removable air tight seal for applying a vacuum to the access tube, such that gas and fluid samples may be drawn through the fluid permeable plate. A fluid sample connector coupled to the removable air tight seal, in addition to the vacuum pump with vacuum gauge/transducer, for withdrawing a fluid sample from the access tube.

Hubbell, J.M.; Sisson, J.B.

1995-12-31T23:59:59.000Z

110

Recent developments in the techniques of controlling and measuring suction in unsaturated soils  

E-Print Network (OSTI)

The difficulty of measuring and controlling suction in unsaturated soils is one of the reasons why the development of the mechanics of unsaturated soils has not been as advanced as that of saturated soils. However, significant developments have been carried out in the last decade in this regard. In this paper, a re-view of some developments carried out in the techniques of controlling suction by using the axis translation, the osmotic method and the vapour control technique is presented. The paper also deals with some recent de-velopments in the direct measurement of suction by using high capacity tensiometers and in the measurement of high suction by using high range psychrometers. The recent progresses made in these techniques have been significant and will certainly help further experimental investigation of the hydromechanical behaviour of un-saturated soils.

Delage, Pierre; Tarantino, Alessandro

2008-01-01T23:59:59.000Z

111

A finite element analysis of the pullout capacity of suction caissons in clay  

E-Print Network (OSTI)

Suction caissons are increasingly becoming the foundation of choice for offshore structures in deep water. They are used extensively in Tension Leg Platforms and provide the most efficient foundations for many offshore ...

Sgardeli, Christina G. (Georgia-Chrysouli C.)

2009-01-01T23:59:59.000Z

112

Low-temperature magnetic refrigerator  

SciTech Connect

The disclosure is directed to a low temperature 4 to 20 K. refrigeration apparatus and method utilizing a ring of magnetic material moving through a magnetic field. Heat exchange is accomplished in and out of the magnetic field to appropriately utilize the device to execute Carnot and Stirling cycles.

Barclay, John A. (Los Alamos, NM)

1985-01-01T23:59:59.000Z

113

Direct condensation refrigerant recovery and restoration system  

Science Conference Proceedings (OSTI)

This patent describes a refrigerant recovery and purification system for removing gaseous refrigerant from a disabled refrigeration unit, cleaning the refrigerant of contaminants, and converting the gaseous refrigerant to a liquid state for storage. It comprises a low pressure inlet section; a high pressure storage section; the low pressure inlet section comprising: an oil and refrigerant gas separator, including a separated oil removal means, first conduit means for connecting an inlet of the separator to the disabled refrigerant unit, a slack-sided accumulator, second conduit means connecting the separator to the slack-sided accumulator, a reclaim condenser, third conduit means connecting the separator and the reclaim condenser in series, an evaporator coil in the reclaim condenser connectable to a conventional operating refrigeration system for receiving a liquid refrigerant under pressure for expansion therein, the evaporator coil forming a condensing surface for condensing the refrigerant gas at near atmospheric pressure in the condenser, a liquid receiver, a reclaimed refrigerant storage tank, fourth conduit means further connecting the liquid receiver in series with the reclaim condenser, downstream thereof, means between the reclaim condenser and the liquid receiver.

Grant, D.C.H.

1992-03-10T23:59:59.000Z

114

Measured Effects of Retrofits - A Refrigerant Oil Additive and a Condenser Spray Device - On the Cooling Performance of a Heat Pump  

E-Print Network (OSTI)

A 15-year old, 3-ton single package air-to-air heat pump was tested in laboratory environmental chambers simulating indoor and outdoor conditions. After documenting initial performance, the unit was retrofitted with a prototype condenser water-spray device and retested. Results at standard AM cooling rating conditions (95°F outdoor dry bulb and 80167 OF indoor dry bulb/wet bulb temperatures) showed the capacity increased by about 7%, and the electric power demand dropped by about 8%, resulting in a steady-state EER increase of 17%. Suction and discharge pressures were reduced by 7 and 37 psi, respectively. A refrigerant oil additive formulated to enhance refrigerant-side heat transfer was added at a dose of one ounce per ton of rated capacity. and the unit was tested for several days at the same 95°F outdoor conditions and showed essentially no increase in capacity, and a slight 3% increase in steady-state EER. Adding more additive lowered the EER slightly. Suction and discharge pressures were essentially unchanged. Our short-term testing showed that the condenser-spray device was effective in increasing the cooling capacity and lowering the electrical demand on an old and relatively inefficient heat pump, but the refrigerant additive had little effect on the cooling performance of our unit Sprayer issues to be resolved include the effect of a sprayer on a new, high-efficiency air conditioner/heat pump, reliable long-term operation, and economics.

Levins, W. P.; Sand, J. R.; Baxter, V. D.; Linkous, R. S.

1996-01-01T23:59:59.000Z

115

Superfluid stirling refrigerator: A new method for cooling below 1 Kelvin  

SciTech Connect

We have invented and built a new type of cryocooler, which we call the superfluid Stirling refrigerator (SSR). The first prototype reached 0.6 K from a starting temperature of 1.2 K. The working fluid of the SSR is the {sup 3}He solute in a superfluid {sup 3}He--{sup 4}He solution. At low temperatures, the superfluid {sup 4}He is in its quantum ground state, and therefore is thermodynamically inert, while the {sup 3}He solute has the thermodynamic properties of a dense ideal gas. Thus, in principle, any refrigeration cycle that can use an ideal gas can also use the {sup 3}He solute as working fluid. In our SSR prototype, bellows-sealed superleak pistons driven by a room-temperature camshaft work on the {sup 3}He solute. Ultimately, we anticipate elimination of moving parts by analogy with pulse-tube refrigeration. 15 refs., 6 figs.

Kotsubo, V.; Swift, G.W.

1990-01-01T23:59:59.000Z

116

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) April 25, 2013 DOE ordered Duracold Refrigeration Manufacturing Company, LLC to pay a $8,000 civil penalty after finding Duracold Refrigeration Manufacturing had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards. The Order adopted a Compromise Agreement, which reflected settlement terms between DOE and Duracold Refrigeration Manufacturing. Duracold Refrigeration Manufacturing: Order (2013-CE-5342) More Documents & Publications Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) North Star Refrigerator: Order (2013-CE-5355) Schott Gemtron: Order (2013-CE-5358

117

Optimal Performance of Quantum Refrigerators  

E-Print Network (OSTI)

A reciprocating quantum refrigerator is studied with the purpose of determining the limitations of cooling to absolute zero. We find that if the energy spectrum of the working medium possesses an uncontrollable gap, then there is a minimum achievable temperature above zero. Such a gap, combined with a negligible amount of noise, prevents adiabatic following during the demagnetization stage which is the necessary condition for reaching $T_c \\to 0$. The refrigerator is based on an Otto cycle where the working medium is an interacting spin system with an energy gap. For this system the external control Hamiltonian does not commute with the internal interaction. As a result during the demagnetization and magnetization segments of the operating cycle the system cannot follow adiabatically the temporal change in the energy levels. We connect the nonadiabatic dynamics to quantum friction. An adiabatic measure is defined characterizing the rate of change of the Hamiltonian. Closed form solutions are found for a const...

Feldmann, Tova

2009-01-01T23:59:59.000Z

118

A compact rotating dilution refrigerator  

E-Print Network (OSTI)

We describe the design and performance of a new rotating dilution refrigerator that will primarily be used for investigating the dynamics of quantized vortices in superfluid 4He. All equipment required to operate the refrigerator and perform experimental measurements is mounted on two synchronously driven, but mechanically decoupled, rotating carousels. The design allows for relative simplicity of operation and maintenance and occupies a minimal amount of space in the laboratory. Only two connections between the laboratory and rotating frames are required for the transmission of electrical power and helium gas recovery. Measurements on the stability of rotation show that rotation is smooth to around 0.001 rad/s up to angular velocities in excess of 2.5 rad/s. The behavior of a high-Q mechanical resonator during rapid changes in rotation has also been investigated.

Fear, M J; Chorlton, D A; Zmeev, D E; Gillott, S J; Sellers, M C; Richardson, P P; Agrawal, H; Batey, G; Golov, A I

2013-01-01T23:59:59.000Z

119

Quantum-enhanced absorption refrigerators  

E-Print Network (OSTI)

Thermodynamics is a branch of science blessed by an unparalleled combination of generality of scope and formal simplicity. Based on few natural assumptions together with the four laws, it sets the boundaries between possible and impossible in macroscopic aggregates of matter. This triggered groundbreaking achievements in physics, chemistry and engineering over the last two centuries. Close analogues of those fundamental laws are now being established at the level of individual quantum systems, thus placing limits on the operation of quantum-mechanical devices. Here we study quantum absorption refrigerators, which are driven by heat rather than external work. We establish thermodynamic performance bounds for these machines and investigate their quantum origin. We also show how those bounds may be pushed beyond what is classically achievable, by suitably tailoring the environmental fluctuations via quantum reservoir engineering techniques. Such superefficient quantum-enhanced cooling realises a promising step towards the technological exploitation of autonomous quantum refrigerators.

Luis A. Correa; José P. Palao; Daniel Alonso; Gerardo Adesso

2013-08-19T23:59:59.000Z

120

Electron tube  

DOE Patents (OSTI)

An electron tube of the present invention includes: a vacuum vessel including a face plate portion made of synthetic silica and having a surface on which a photoelectric surface is provided, a stem portion arranged facing the photoelectric surface and made of synthetic silica, and a side tube portion having one end connected to the face plate portion and the other end connected to the stem portion and made of synthetic silica; a projection portion arranged in the vacuum vessel, extending from the stem portion toward the photoelectric surface, and made of synthetic silica; and an electron detector arranged on the projection portion, for detecting electrons from the photoelectric surface, and made of silicon.

Suyama, Motohiro (Hamamatsu, JP); Fukasawa, Atsuhito (Hamamatsu, JP); Arisaka, Katsushi (Los Angeles, CA); Wang, Hanguo (North Hills, CA)

2011-12-20T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Compatibility of refrigerants and lubricants with elastomers  

SciTech Connect

Information contained in this reporters designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. Swell measurements have been made on approximately 50% of the proposed elastomers (94 total)in both the lubricant (7 total) and refrigerant (10 total) materials. Swell behavior in the these fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1992-07-01T23:59:59.000Z

122

Transport Refrigeration Units: A Technical Assessment  

Science Conference Proceedings (OSTI)

This report evaluates the prospects for operating transport refrigeration systems on electricity while they are stationary at a distribution center or refrigerated warehouses. Because most transport refrigeration units (TRUs) in use today are powered by diesel engines, concentrations of diesel exhaust products including particulate matter occur near these distribution centers. Operating TRUs on electricity would eliminate diesel exhaust emissions concentrations at these facilities, but would increase cos...

2004-09-29T23:59:59.000Z

123

Modeling the effects of Refrigerant Charging on Air Conditioner Performance Characteristics For Three Expansion Devices  

E-Print Network (OSTI)

An experimental and analytical study concerned with the off-design refrigerant charging of air conditioners is presented. A series of experiments were conducted to characterize the effects of refrigerant charge and type of expansion device on the system performance (capacity, EER, SEER, etc.) of an air conditioner. All experiments were performed according to the ASHRAE Standard [1983]. The effects of off-design refrigerant charge in the system, type of expansion device (capillary tube, TXV, and short-tube orifice), and outdoor dry-bulb temperature (82° to l00°F) on the wet and dry steady state and cyclic tests are addressed in this study. The fully charged condition was established as a base case for all the expansion device systems. A full charge was obtained by charging the unit to the superheat or subcooled condition specified by the manufacturer charging chan. Once the full charge was determined, refrigerant was then added in 5% increments from -20% of full charge to +20% of full charge to cover the full range of charging conditions for a particular expansion device being tested. The investigation of off-design charging indicated that the system performance variables (total capacity, EER, and SEER) of the unit with capillary tube were more sensitive to off-design charging than the systems with TXV and short-tube orifice. From -20% to +20% charging, the capacity and EER showed a strong dependence on the outdoor temperature, but varied little with charge for the TXV and short-tube orifice expansion systems. A -20% charging resulted in a 21% reduction in SEER while a +20% charging produced an 11% reduction in SEER for the unit with capillary tube. For the TXV, SEER dropped 2% and 8% for -20% and +20% refrigerant charging, respectively. The SEER was constant at 9.4 for all the charging condition except for -5% charging where it peaked to 9.9 for the short-tube orifice expansion system. This trend would suggest that the range of sensitivity of a short-tube orifice system is confined within a small refrigerant charge. A new heat exchanger model based on tube-by-tube simulation was developed and integrated into the ORNL heat pump model. The model was capable of simulating the steady state response of a vapor compression air-to-air heat pump and air conditioner commonly used in residential applications. The simulated results were compared with laboratory tests at two outdoor temperatures. It was found that the ORNL model estimates were within an average of 3% of the experimental results from - 10% to +10% charging conditions. The model predicted the system performance up to 8% higher than measured results at +/-20% and +/-15% charging conditions. Among the eight void fraction models studied, the Hughmark model showed the best agreement between superheat and subcooled temperatures, refrigerant flow rate and capacity and the measured results.

Farzad, Mohsen

1990-08-01T23:59:59.000Z

124

Suction effects on feedpump performance: a literature survey. [Problems in feedwater system  

Science Conference Proceedings (OSTI)

The influence of suction effects on the performance of main boiler feed and booster pumps has been analysed. This report provides a critical literature survey of this topic and is the first step on the way to recommendations for pump and plant (architect) engineers. The problems surveyed can roughly be reduced to two main emphases: Effects on boiler feed pumps and their suction system during standby after shut-off, and the various protection systems. Effects of deaerator transients on suction pressure of boiler feed pumps due to a fast reduction of turbine load or a turbine trip, and the various protection systems. Going beyond a pure literature survey, step-by-step methods have been outlined to calculate the optimum suction pipe diameter as well as the influence of various suction systems and plant parameters on pump performance. Although further work remains to be done, many analytical approaches in this report can be used now as a guide when planning a power station. 40 refs., 51 figs.

de Vries, M.; Simon, A.

1985-08-01T23:59:59.000Z

125

List of Refrigerators Incentives | Open Energy Information  

Open Energy Info (EERE)

Refrigerators Incentives Refrigerators Incentives Jump to: navigation, search The following contains the list of 657 Refrigerators Incentives. CSV (rows 1-500) CSV (rows 501-657) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial Custom Project Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Tribal Government Boilers Central Air conditioners Chillers Custom/Others pending approval Furnaces Heat pumps Heat recovery Lighting Lighting Controls/Sensors Processing and Manufacturing Equipment Refrigerators Yes AEP Ohio - Commercial Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial

126

Building Technologies Office: Refrigerated Beverage Vending Machines...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Use to Save Money. Learn More. News DOE Issues Notice of Proposed Rulemaking for Commercial Refrigeration Equipment Energy Conservation Standard August 29, 2013 DOE Issues...

127

Regenerator for Magnetic Refrigerants - Energy Innovation Portal  

Magnetic refrigeration is being investigated as an alternative to conventional gas compressor technology ... because of its potential to save energy and ...

128

An Alternative Refrigeration System For Automotive Applications.  

E-Print Network (OSTI)

??The air conditioning systems currently utilized in automobiles are the vapor compression systems. This type of system has many disadvantages: the refrigerant used is not… (more)

McLaughlin, Shannon

2005-01-01T23:59:59.000Z

129

Multi-stage Cascaded Stirling Refrigerator  

NLE Websites -- All DOE Office Websites (Extended Search)

have developed a multi-stage refrigerator, designed to recapture and utilize the acoustic energy that would ordinarily be wasted in traditional Stirling configurations. Available...

130

NIST Quantum Refrigerator Offers Extreme Cooling and ...  

Science Conference Proceedings (OSTI)

... NIST's prototype solid-state refrigerator uses quantum physics in the square chip mounted on the green circuit board to cool the much larger copper ...

2013-03-05T23:59:59.000Z

131

Magnetic Refrigeration a 21 - Programmaster.org  

Science Conference Proceedings (OSTI)

Presentation Title, Magnetic Refrigeration a 21st Century Highly Efficient and Green ... Alloy Design and Powder Processing of Mn-Al Based Materials for Rare

132

Tube furnace  

DOE Patents (OSTI)

A vermiculite insulated tube furnace is heated by a helically-wound resistance wire positioned within a helical groove on the surface of a ceramic cylinder, that in turn is surroundingly disposed about a doubly slotted stainless steel cylindrical liner. For uniform heating, the pitch of the helix is of shorter length over the two end portions of the ceramic cylinder. The furnace is of large volume, provides uniform temperature, offers an extremely precise programmed heating capability, features very rapid cool-down, and has a modest electrical power requirement.

Foster, K.G.; Frohwein, E.J.; Taylor, R.W.; Bowen, D.W.

1990-01-01T23:59:59.000Z

133

Tube Degradation  

E-Print Network (OSTI)

On March 23, 2012, Southern California Edison (SCE) submitted a letter (Reference 1) to the NRC describing actions it planned to take with respect to issues identified in the steam generator (SG) tubes of San Onofre Nuclear Generating Station (SONGS) Units 2 and 3. On March 27,2012, the NRC responded by issuing a Confirmatory Action Letter (CAL) (Reference 2), describing the actions that the NRC and SCE agreed would be completed to address those issues and ensure safe operations. The purpose of this letter is to report the completion of the Unit 2 CAL actions, which are to be completed prior to entry of Unit 2 into

An Edison; Inter Natlonal Compan; Peter T. Dietrich; Elmo E. Collins; Regional Administrator; Region Iv

2012-01-01T23:59:59.000Z

134

Federal Energy Management Program: Covered Product Category: Refrigerated  

NLE Websites -- All DOE Office Websites (Extended Search)

Refrigerated Beverage Vending Machines to someone by E-mail Refrigerated Beverage Vending Machines to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Google Bookmark Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Delicious Rank Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on AddThis.com...

135

DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements March 16, 2010 - 4:28pm...

136

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

... style refrigerator and a freezerless household refrigerator used ... possible that the nature of the cooling system and ... model simply do not cool the side ...

2012-08-02T23:59:59.000Z

137

Air-Conditioning, Heating, and Refrigeration Institute (AHRI...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI These comments...

138

U.S. Residential Miscellaneous Refrigeration Products: Results...  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys Title U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon...

139

COMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATION SYSTEMS  

E-Print Network (OSTI)

be used to design and optimize refrigeration cycles as wellCOMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATIONTrial Design Fixed state parameters (bar) Refrigeration

green, M.A.

2011-01-01T23:59:59.000Z

140

China Refrigerator Information Label: Specification Development and Potential Impact  

E-Print Network (OSTI)

ERKELEY N ATIONAL L ABORATORY China Refrigerator InformationDivision Jianhong Cheng China National Institute of7 Table 2 Coefficient Values for China Refrigerator 2003

Fridley, David

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Design and analysis of a 5-MW vertical-fluted-tube condenser for geothermal applications  

DOE Green Energy (OSTI)

The design and analysis of an industtial-sized vertical-fluted-tube condenser. The condenser is used to condense superheated isobutane vapor discharged from a power turbine in a geothermal test facility operated for the US Department of Energy. The 5-MW condenser has 1150 coolant tubes in a four-pass configuration with a total heat transfer area of 725 m/sup 2/ (7800 ft/sup 2/). The unit is being tested at the Geothermal Components Test Facility in the Imperial Valley of East Mesa, California. The condenser design is based on previous experimental research work done at the Oak Ridge National Laboratory on condensing refrigerants on a wide variety of single vertical tubes. Condensing film coefficients obtained on the high-performance vertical fluted tubes in condensing refrigerants are as much as seven times greater than those obtained with vertical smooth tubes that have the same diameter and length. The overall heat transfer performance expected from the fluted tube condenser is four to five times the heat transfer obtained from the identical units employing smooth tubes. Fluted tube condensers also have other direct applications in the Ocean Thermal Energy Conversion (OTEC) program in condensing ammonia, in the petroleum industry in condensing light hydrocarbons, and in the air conditioning and refrigeration industry in condensing fluorocarbon vapors.

Llewellyn, G.H.

1982-03-01T23:59:59.000Z

142

Seven-effect absorption refrigeration  

DOE Patents (OSTI)

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit.

DeVault, Robert C. (Knoxville, TN); Biermann, Wendell J. (Fayetteville, NY)

1989-01-01T23:59:59.000Z

143

Seven-effect absorption refrigeration  

DOE Patents (OSTI)

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit. 1 fig.

DeVault, R.C.; Biermann, W.J.

1989-05-09T23:59:59.000Z

144

Design of Industrial Process Refrigeration Systems  

E-Print Network (OSTI)

When considering electric driven refrigeration compressors, proper integration with the process may result in reduced power consumption. However, the total utility situation must be considered when evaluating the compressor driver. Conversion from steam drivers to electric drivers may be more economical when considering proper process integration. These questions and various scenarios must be addressed in light of the total process requirements and constraints. During the last few years, Union Carbide has successfully applied ADVENT™ technology to several complex processes that utilize refrigeration systems. In most cases the design of a complex refrigeration system in isolation (i.e., without considering process integration) generally results in non-optimum refrigeration levels and excessive refrigeration consumption. By applying ADVENT™ Process Integration Technologv to these non-optimal designs, retrofit projects have emerged that clearly identify how to optimize the existing design with good project economics. This paper presents the results of an ADVENT Process Integration Study for the Electric Power Research Institute (EPRI) of Palo Alto, California. The study objective was to demonstrate process synthesis techniques for retrofit design in two industrial refrigeration intensive processes: an olefins process and a beer brewery process. Study results for each retrofit design are explained along with generalized guidelines for application to other processes. An industry scoping portion of the study is discussed in terms of identifying refrigeration intensive processes. Specific and general conclusions are presented to help facilitate proper industrial refrigeration system design throughout the industry.

Witherell, W. D.

1987-09-01T23:59:59.000Z

145

Date | 1Refrigeration and Air Conditioning EMA Education and Training Date | 2Refrigeration and Air Conditioning EMA Education and Training  

E-Print Network (OSTI)

Date | 1Refrigeration and Air Conditioning EMA Education and Training #12;Date | 2Refrigeration Flow Coil Design etc. Finger Print Relationship Every evaporator is unique Unstable Region * = examples

Oak Ridge National Laboratory

146

Compatibility of refrigerants and lubricants with elastomers  

Science Conference Proceedings (OSTI)

The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on availability of additional R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1993-01-01T23:59:59.000Z

147

Compatibility of refrigerants and lubricants with elastomers  

Science Conference Proceedings (OSTI)

Information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on the availability of additional quantities of R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1992-10-01T23:59:59.000Z

148

Optimal Performance of Quantum Refrigerators  

E-Print Network (OSTI)

A reciprocating quantum refrigerator is studied with the purpose of determining the limitations of cooling to absolute zero. We find that if the energy spectrum of the working medium possesses an uncontrollable gap, then there is a minimum achievable temperature above zero. Such a gap, combined with a negligible amount of noise, prevents adiabatic following during the demagnetization stage which is the necessary condition for reaching $T_c \\to 0$. The refrigerator is based on an Otto cycle where the working medium is an interacting spin system with an energy gap. For this system the external control Hamiltonian does not commute with the internal interaction. As a result during the demagnetization and magnetization segments of the operating cycle the system cannot follow adiabatically the temporal change in the energy levels. We connect the nonadiabatic dynamics to quantum friction. An adiabatic measure is defined characterizing the rate of change of the Hamiltonian. Closed form solutions are found for a constant adiabatic measure for all the cycle segments. We have identified a family of quantized frictionless cycles with increasing cycle times. These cycles minimize the entropy production. Such frictionless cycles are able to cool to $T_c=0$. External noise on the controls eliminates these frictionless cycles. The influence of phase and amplitude noise on the demagnetization and magnetization segments is explicitly derived. An extensive numerical study of optimal cooling cycles was carried out which showed that at sufficiently low temperature the noise always dominates restricting the minimum temperature.

Tova Feldmann; Ronnie Kosloff

2009-06-04T23:59:59.000Z

149

Novel materials for laser refrigeration  

SciTech Connect

The status of optical refrigeration of rare-earth-doped solids is reviewed, and the various factors that limit the performance of current laser-cooling materials are discussed. Efficient optical refrigeration is possible in materials for which {Dirac_h}{omega}{sub max} < E{sub p}/8, where {Dirac_h}{omega}{sub max} is the maximum phonon energy of the host material and E{sub p} is the pump energy of the rare-earth dopant. Transition-metal and OH{sup -}impurities at levels >100 ppb are believed to be the main factors for the limited laser-cooling performance in current materials. The many components of doped ZBLAN glass pose particular processing challenges. Binary fluoride glasses such as YF{sub 3}-LiF are considered as alternatives to ZBLAN. The crystalline system KPb{sub 2}CI{sub 5} :Dy{sup 3+} is identified as a prime candidate for high-efficiency laser cooling.

Hehlen, Markus P [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

150

Tube-in-tube thermophotovoltaic generator  

DOE Patents (OSTI)

A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell. 8 figs.

Ashcroft, J.; Campbell, B.; DePoy, D.

1998-06-30T23:59:59.000Z

151

Tube-in-tube thermophotovoltaic generator  

DOE Patents (OSTI)

A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell.

Ashcroft, John (Scotia, NY); Campbell, Brian (Scotia, NY); DePoy, David (Clifton Park, NY)

1998-01-01T23:59:59.000Z

152

A tube-in-tube thermophotovoltaic generator  

DOE Patents (OSTI)

A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell.

Ashcroft, J.; Campbell, B.; Depoy, D.

1996-12-31T23:59:59.000Z

153

Waste Heat Recovery from Refrigeration in a Meat Processing Facility  

E-Print Network (OSTI)

A case study is reviewed on a heat recovery system installed in a meat processing facility to preheat water for the plant hot water supply. The system utilizes waste superheat from the facility's 1,350-ton ammonia refrigeration system. The heat recovery system consists of a shell and tube heat exchanger (16"? x 14'0") installed in the compressor hot gas discharge line. Water is recirculated from a 23,000-gallon tempered water storage tank to the heat exchanger by a circulating pump at the rate of 100 gallons per minute. All make-up water to the plant hot water system is supplied from this tempered water storage tank, which is maintained at a constant filled level. Tests to determine the actual rate of heat recovery were conducted from October 3, 1979 to October 12, 1979, disclosing an average usage of 147,000 gallons of hot water daily. These tests illustrated a varied heat recovery of from 0.5 to 1.0 million BTU per hour. The deviations were the result of both changing refrigeration demands and compressor operating modes. An average of 16 million BTU per day was realized, resulting in reduced boiler fuel costs of $30,000 annually, based on the present $.80 per gallon #2 fuel oil price. At the total installed cost of $79,000, including test instrumentation, the project was found to be economically viable. The study has demonstrated the technical and economic feasibility of refrigeration waste heat recovery as a positive energy conservation strategy which has broad applications in industry and commerce.

Murphy, W. T.; Woods, B. E.; Gerdes, J. E.

1980-01-01T23:59:59.000Z

154

Ultimate capacity of suction caisson in normally and lightly overconsolidated clays  

E-Print Network (OSTI)

Petroleum exploration and production in recent years have moved into increasingly deeper water off the continental shelf. Some of these facilities are anchored in water depths in excess of 1000 meters. Exploration and production in deep water present new technological challenges where traditional fixed platforms have given way to floating structures. Today suction caissons are the most commonly used anchorage system for permanent offshore oil production facility. The objective of this study is to numerically predict the ultimate capacity of suction caissons in normally consolidated and lightly overconsolidated clays. Representative soil profile from the Gulf of Mexico and the North Sea are taken and analyzed for suction caissons with length over diameter ratios of 2, 4, 6 & 8. Normalized failure load interaction diagrams are generated for each of the cases. The location of optimum attachment point is also reported for each of the cases. General purpose finite element computer program ABAQUS is used for the numerical prediction. The finite element study is carried out with three-dimensional models using hybrid elements. A simplified elastic perfectly plastic model with von-Mises yield criterion is used for the study. The saturated clay is treated as an incompressible material. Results of the study compares well with existing simplified method for estimating load capacity of suction caisson anchors.

Sharma, Partha Pratim

2006-05-01T23:59:59.000Z

155

Refrigerant Phase-Change Stirling-Cycle Solar Power Towers  

Science Conference Proceedings (OSTI)

This paper firstly introduces the principles of Refrigerant Phase-Change Stirling-Cycle solar power towers This heat engines use solar reservoire. When the refrigerant in an engine cylinder absorbs heat from high-temperature heat sources, refrigerant ... Keywords: refrigerant phase-change cycle, heat engines, solar power tower, finite-time thermodynamics

Dezhong Huang

2011-01-01T23:59:59.000Z

156

Control system for heat exchangers fans in a refrigeration system  

Science Conference Proceedings (OSTI)

The paper presents a method for controlling evaporator and condenser fans in a refrigeration system. The refrigeration system includes a refrigerant circuit defined by a compressor, a condenser, a throttling device, and an evaporator. The system includes ... Keywords: controlling, fan, refrigeration system, variable frequency drive unit

Cristian Iosifescu; Valeriu Damian; C?lin Ciufudean

2010-05-01T23:59:59.000Z

157

Dual-circuit, multiple-effect refrigeration system and method  

DOE Patents (OSTI)

A dual circuit absorption refrigeration system comprising a high temperature single-effect refrigeration loop and a lower temperature double-effect refrigeration loop separate from one another and provided with a double-condenser coupling therebetween. The high temperature condenser of the single-effect refrigeration loop is double coupled to both of the generators in the double-effect refrigeration loop to improve internal heat recovery and a heat and mass transfer additive such as 2-ethyl-1-hexanol is used in the lower temperature double-effect refrigeration loop to improve the performance of the absorber in the double-effect refrigeration loop.

DeVault, Robert C. (Knoxville, TN)

1995-01-01T23:59:59.000Z

158

Bearing construction for refrigeration compresssor  

DOE Patents (OSTI)

A hermetic refrigeration compressor has a cylinder block and a crankshaft rotatable about a vertical axis to reciprocate a piston in a cylinder on the cylinder block. A separate bearing housing is secured to the central portion of the cylinder block and extends vertically along the crankshaft, where it carries a pair of roller bearings to journal the crankshaft. The crankshaft has a radially extending flange which is journaled by a thrust-type roller bearing above the bearing housing to absorb the vertical forces on the crankshaft so that all three of the roller bearings are between the crankshaft and the bearing housing to maintain and control the close tolerances required by such bearings.

Middleton, Marc G. (Wyoming, MI); Nelson, Richard T. (Worthington, OH)

1988-01-01T23:59:59.000Z

159

Optimization of Industrial Refrigeration Systems  

E-Print Network (OSTI)

A computer program designed to optimize the size of an evaporative condenser in a two-stage industrial refrigeration plant was created. The program sizes both the high-stage and low-stage compressors and an evaporative condenser. Once the initial system is sized, a year long plant simulation is performed resulting in electric energy consumption profile and an exergy destruction profile for each component and for the system. The program uses actual regional hourly outside dry bulb and wet bulb temperatures for both sizing and simulation. An exergoeconomic optimization uses the results of the simulation combined with component and energy costs to optimize the condenser size such that both plant costs and energy losses are minimized.

Flack, P. J.; Sharp, M. K.; Case, M. E.; Gregory, R. W.; Case, P. L.

1995-04-01T23:59:59.000Z

160

Heat exchanger tube mounts  

DOE Patents (OSTI)

A heat exchanger in which tubes are secured to a tube sheet by internal bore welding is described. The tubes may be moved into place in preparation for welding with comparatively little trouble. A number of segmented tube support plates are provided which allow a considerable portion of each of the tubes to be moved laterally after the end thereof has been positioned in preparation for internal bore welding to the tube sheet. (auth)

Wolowodiuk, W.; Anelli, J.; Dawson, B.E.

1974-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Evaporation heat transfer and friction characteristics of R-134a flowing downward in a vertical corrugated tube  

SciTech Connect

Differently from most previous studies, the heat transfer and friction characteristics of the pure refrigerant HFC-134a during evaporation inside a vertical corrugated tube are experimentally investigated. The double tube test sections are 0.5 m long with refrigerant flowing in the inner tube and heating water flowing in the annulus. The inner tubes are one smooth tube and two corrugated tubes, which are constructed from smooth copper tube of 8.7 mm inner diameter. The test runs are performed at evaporating temperatures of 10, 15, and 20 C, heat fluxes of 20, 25, and 30 kW/m{sup 2}, and mass fluxes of 200, 300, and 400 kg/m{sup 2} s. The quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The pressure drop across the test section is measured directly by a differential pressure transducer. The effects of heat flux, mass flux, and evaporation temperature on the heat transfer coefficient and two-phase friction factor are also discussed. It is found that the percentage increases of the heat transfer coefficient and the two-phase friction factor of the corrugated tubes compared with those of the smooth tube are approximately 0-10% and 70-140%, respectively. (author)

Aroonrat, Kanit; Wongwises, Somchai [Fluid Mechanics, Thermal Engineering and Multiphase Flow Research Lab. (FUTURE), Department of Mechanical Engineering, King Mongkut's University of Technology Thonburi, Bangmod, Bangkok 10140 (Thailand)

2011-01-15T23:59:59.000Z

162

Small Commercial Refrigeration Incentive | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive < Back Eligibility Agricultural Commercial Industrial Institutional Nonprofit Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Incentives over $5,000 must be pre-approved Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Outside Air Economizers: $1,250 Evaporator Fan Motors: $20 - $100 Evaporator Fan Motor Controls: $550 Door/Frame Heater Controls: $50 per door Case Light Occupancy Controls: $40 LED Refrigerator and Freezer Case Light Fixtures: $6 - $15 per foot Energy Star Ice Machines: $50 - $75 Efficient Compressors: $200 Display Case Strip-Curtain and Continuous Covers: $6 per foot

163

Cospolich Refrigerator: Proposed Penalty (2013-CE-5314)  

Energy.gov (U.S. Department of Energy (DOE))

DOE alleged in a Notice of Proposed Civil Penalty that Cospolich Refrigerator Co, Inc. failed to certify walk-in cooler or freezer components as compliant with the energy conservation standards.

164

Refrigerator Manufacturers: Proposed Penalty (2013-CE-5341)  

Energy.gov (U.S. Department of Energy (DOE))

DOE alleged in a Notice of Proposed Civil Penalty that Refrigerator Manufacturers, LLC failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards.

165

Defrost Temperature Termination in Supermarket Refrigeration Systems  

SciTech Connect

The objective of this project was to determine the potential energy savings associated with implementing demand defrost strategies to defrost supermarket refrigerated display case evaporators, as compared to the widely accepted current practice of controlling display case defrost cycles with a preset timer. The defrost heater energy use of several representative display case types was evaluated. In addition, demand defrost strategies for refrigerated display cases as well as those used in residential refrigerator/freezers were evaluated. Furthermore, it is anticipated that future work will include identifying a preferred defrost strategy, with input from Retail Energy Alliance members. Based on this strategy, a demand defrost system will be designed which is suitable for supermarket refrigerated display cases. Limited field testing of the preferred defrost strategy will be performed in a supermarket environment.

Fricke, Brian A [ORNL; Sharma, Vishaldeep [ORNL

2011-11-01T23:59:59.000Z

166

Loveland Water & Power- Refrigerator Recycling Program  

Energy.gov (U.S. Department of Energy (DOE))

Loveland Water & Power is providing an incentive for its customers to recycle their old refrigerators. Interested customers can call the utility to arrange a time to pick up the old...

167

Elastic Metal Alloy Refrigerants: Thermoelastic Cooling  

SciTech Connect

BEETIT Project: UMD is developing an energy-efficient cooling system that eliminates the need for synthetic refrigerants that harm the environment. More than 90% of the cooling and refrigeration systems in the U.S. today use vapor compression systems which rely on liquid to vapor phase transformation of synthetic refrigerants to absorb or release heat. Thermoelastic cooling systems, however, use a solid-state material—an elastic shape memory metal alloy—as a refrigerant and a solid to solid phase transformation to absorb or release heat. UMD is developing and testing shape memory alloys and a cooling device that alternately absorbs or creates heat in much the same way as a vapor compression system, but with significantly less energy and a smaller operational footprint.

2010-10-01T23:59:59.000Z

168

Refrigeration system having standing wave compressor  

DOE Patents (OSTI)

A compression-evaporation refrigeration system, wherein gaseous compression of the refrigerant is provided by a standing wave compressor. The standing wave compressor is modified so as to provide a separate subcooling system for the refrigerant, so that efficiency losses due to flashing are reduced. Subcooling occurs when heat exchange is provided between the refrigerant and a heat pumping surface, which is exposed to the standing acoustic wave within the standing wave compressor. A variable capacity and variable discharge pressure for the standing wave compressor is provided. A control circuit simultaneously varies the capacity and discharge pressure in response to changing operating conditions, thereby maintaining the minimum discharge pressure needed for condensation to occur at any time. Thus, the power consumption of the standing wave compressor is reduced and system efficiency is improved.

Lucas, Timothy S. (Glen Allen, VA)

1992-01-01T23:59:59.000Z

169

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network (OSTI)

Amarnath, M. Blatt, Variable refrigerant flow: where, why,simulation in the variable refrigerant flow air-conditioningsimulation of the variable refrigerant flow air conditioning

Hong, Tainzhen

2010-01-01T23:59:59.000Z

170

Opportunities for Energy Efficiency and Automated Demand Response in Industrial Refrigerated Warehouses in California  

E-Print Network (OSTI)

D. Brown (2004). Industrial Refrigeration Best PracticesD. Brown (2004). Industrial Refrigeration Best Practicesoutlet – common in industrial refrigeration Source: Wilcox,

Lekov, Alex

2009-01-01T23:59:59.000Z

171

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network (OSTI)

refrigeration products use vapor compression technology toicemakers and non-vapor compression refrigerators and+4.5) million non-vapor compression refrigerators in U.S.

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

172

Working Fluids Low Global Warming Potential Refrigerants  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Working Fluids Low GWP Working Fluids Low GWP Refrigerants - CRADA Ed Vineyard Oak Ridge National Laboratory vineyardea@ornl.gov (865) 574-0576 3 April 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: - High GWP refrigerants increase CO 2 equivalent emissions for HVAC&R equipment - Low GWP alternatives may increase energy consumption, introduce safety risks, require significant modifications to equipment, and have higher costs

173

Combined cold compressor/ejector helium refrigerator  

DOE Patents (OSTI)

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, Donald P. (Southold, NY)

1985-01-01T23:59:59.000Z

174

Working Fluids Low Global Warming Potential Refrigerants  

NLE Websites -- All DOE Office Websites (Extended Search)

Working Fluids Low GWP Working Fluids Low GWP Refrigerants - CRADA Ed Vineyard Oak Ridge National Laboratory vineyardea@ornl.gov (865) 574-0576 3 April 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: - High GWP refrigerants increase CO 2 equivalent emissions for HVAC&R equipment - Low GWP alternatives may increase energy consumption, introduce safety risks, require significant modifications to equipment, and have higher costs

175

ARI delegation to Japan on Alternative Refrigerants  

SciTech Connect

Researchers from ARI member companies spoke at the International Conference on Alternative Refrigerants in Tokyo and visited several Japanese organizations for the purpose of exchanging information on alternative refrigerants. The specific purpose of the meetings was to review the methods being utilized to screen alternatives to CFCs and HCFCs: materials compatibility screening methods, lubricant testing techniques, as well as flammability studies. A list of papers presented at the conference is included.

Not Available

1993-02-01T23:59:59.000Z

176

BNL Refrigerant Overview Presentation to the  

E-Print Network (OSTI)

0.25 4700 Cold boxes, environmental chambers R-718 Water 212 0 N/A Steam-driven absorption chiller 4750 Older centrifugal chillers (>200 tons) R-12 CFC -20 1 10900 Old refrigerators and vehicle A/C R-13/C mach. R-123 HCFC 81 1.3 77 Newer centrifugal chillers (>200 tons) R-134a HFC -15 0 1430 Refrigerators

Homes, Christopher C.

177

Combined cold compressor/ejector helium refrigerator  

DOE Patents (OSTI)

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, D.P.

1984-06-05T23:59:59.000Z

178

Ground Loops for Heat Pumps and Refrigeration  

E-Print Network (OSTI)

Ground loops are used for water source heat pumps. Refrigeration can be put on a ground loop. Water-cooled condensing units are more efficient than air-cooled, and they can be put indoors. Indoor location makes piping for desuperheater hot water easy. Since refrigeration equipment runs more than heat pumps, energy savings can be large for ground-coupled refrigeration. The paper presents a design procedure for ground loops for heat pumps, hot water, ice machines, and water-cooled refrigeration. It gives an overview of the commercial ground-coupled systems in Louisiana that have both refrigeration and heat pumps. Systems vary from small offices to a three-story office building with 187 tons. A chain of hamburger outlets uses total ground-coupling in all of its stores. A grocery store has ground-coupling for heat pumps and refrigeration. Desuperheaters provide 80 percent of the hot water for a coin laundry in the same building. A comparison of energy costs in a bank with a ground-coupled heat pump system to a similar bank with air-conditioning and gas for heat revealed a 31 percent reduction in utility costs for the ground-coupled building. Two buildings of the Mississippi Power and Light Co. have ground-coupled heat pumps in one, and high efficiency air source heat pumps in the other. Energy savings in nine months was 60,000 kWh (25 percent), and electric peak demand was reduced 42 kW (35 percent).

Braud, H. J.

1986-01-01T23:59:59.000Z

179

Global warming impacts of ozone-safe refrigerants and refrigeration, heating, and air-conditioning technologies  

SciTech Connect

International agreements mandate the phase-out of many chlorine containing compounds that are used as the working fluid in refrigeration, air-conditioning, and heating equipment. Many of the chemical compounds that have been proposed, and are being used in place of the class of refrigerants eliminated by the Montreal Protocol are now being questioned because of their possible contributions to global warming. Natural refrigerants are put forth as inherently superior to manufactured refrigerants because they have very low or zero global warming potentials (GWPs). Questions are being raised about whether or not these manufactured refrigerants, primarily hydrofluorocarbons (HFCs), should be regulated and perhaps phased out in much the same manner as CFCs and HCFCs. Several of the major applications of refrigerants are examined in this paper and the results of an analysis of their contributions to greenhouse warming are presented. Supermarket refrigeration is shown to be an application where alternative technologies have the potential to reduce emissions of greenhouse gases (GHG) significantly with no clear advantage to either natural or HFC refrigerants. Mixed results are presented for automobile air conditioners with opportunities to reduce GHG emissions dependent on climate and comfort criteria. GHG emissions for hermetic and factory built systems (i.e. household refrigerators/freezers, unitary equipment, chillers) are shown to be dominated by energy use with much greater potential for reduction through efficiency improvements than by selection of refrigerant. The results for refrigerators also illustrate that hydrocarbon and carbon dioxide blown foam insulation have lower overall effects on GHG emissions than HFC blown foams at the cost of increased energy use.

Fischer, S.; Sand, J.; Baxter, V.

1997-12-01T23:59:59.000Z

180

Low-GWP Refrigerants Research Project | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emerging Technologies » Low-GWP Refrigerants Research Project Emerging Technologies » Low-GWP Refrigerants Research Project Low-GWP Refrigerants Research Project The U.S. Department of Energy is currently conducting research into low global warming potential (GWP) refrigerants. As concerns about climate change intensify, it is becoming increasingly clear that suitable low-GWP refrigerants will be needed for both new and existing residential and commercial heating, ventilation, air conditioning, and refrigeration (HVAC&R) equipment. Project Description This project seeks to develop alternative refrigerants for HVAC&R equipment. The overall environmental impacts of alternative refrigerants will be assessed using a life cycle climate performance model that accounts for direct emissions associated with refrigerant leaks and indirect

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

An air cooled tube-fin evaporator model for an expansion valve control law  

Science Conference Proceedings (OSTI)

For control purposes, a mathematical model of a tube-fin evaporator of a vapour compression plant running with R22 is analyzed. The refrigerant behavior in an evaporating region is described by a homogeneous model. The balance equations, together with ... Keywords: Control devices, Evaporator models, Heat transfer, Nonlinear differential systems, Numerical methods, Phase transition

C. Aprea; C. Renno

1999-10-01T23:59:59.000Z

182

Well simulation using Refrigerant 114  

DOE Green Energy (OSTI)

A simple method for the investigation of thermodynamic (substance) similarity in the two-phase domain is introduced based on the assumptions of a simplified model fluid. According to this method, the investigation of the conditions for thermodynamic similarity between substances in the two-phase region reveals the important role the latent heat of evaporation (h/sub fg/) plays in the definition of the property scales. These greatly influence the dynamic and geometric similarity of the process under investigation. The introduction of the thermodynamic similarity property scales into the energy conservation equations for a certain process (e.g., flow up a geothermal well) brings forth a thermodynamic length scale and kinetic energy scale. Refrigerant 114 has been examined for similarity with water substance according to this method and found to be adequate for geothermal well simulation in the laboratory. Low pressures and temperatures and a substantial reduction of mass flow rates and geometric scales are a few of the advantages of using R114 for such experiments.

Nikitopoulos, D.E.; Dickinson, D.A.; DiPippo, R.; Maeder, P.F.

1984-06-01T23:59:59.000Z

183

DOE Closes Investigation of Arcelik's Blomberg Refrigerator | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Arcelik's Blomberg Refrigerator Arcelik's Blomberg Refrigerator DOE Closes Investigation of Arcelik's Blomberg Refrigerator September 1, 2010 - 4:37pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Arcelik's Blomberg refrigerator-freezer model # BRFB1450. The Department opened this investigation based on a complaint. DOE subpoenaed information from Arcelik, reviewed Arcelik's response, and performed its own testing of this model. Based on our investigation and test results, DOE has determined this model to be compliant with federal energy conservation standards. Notice of Compliance Determination Addthis Related Articles DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Closes Investigation of Whirlpool's Maytag Refrigerator

184

High Efficiency Low Emission Supermarket Refrigeration Research Project |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High Efficiency Low Emission Supermarket High Efficiency Low Emission Supermarket Refrigeration Research Project High Efficiency Low Emission Supermarket Refrigeration Research Project The U.S. Department of Energy (DOE) is currently conducting research into high efficiency, low emission supermarket refrigeration technologies. Project Description The project involves the development of a supermarket refrigeration system that can reduce greenhouse gas emissions and energy consumption when compared to existing systems. The challenge is to design a system that is capable of achieving low refrigerant leak rates while significantly reducing both the energy consumption and the refrigerant charge size. Project Partners Research is being undertaken between DOE and Oak Ridge National Laboratory. Project Goals

185

Multiple-Zone Variable Refrigerant Flow System Modeling and Equipment Performance Mapping  

Science Conference Proceedings (OSTI)

We developed a variable refrigerant flow (VRF) vapor compression system model, which has five indoor units, one outdoor unit and one water heater. The VRF system can run simultaneous space conditioning (cooling or heating) and water heating. The indoor units and outdoor unit use fin-&-tube coil heat exchangers, and the water heater uses a tube-in-tube heat exchanger. The fin-&-tube coil heat exchangers are modeled using a segment-by-segment approach and the tube-in-tube water heater is modeled using a phase-by-phase approach. The compressor used is a variable-speed rotary design. We calibrated our model against a manufacturer s product literature. Based on the vapor compression system model, we investigated the methodology for generating VRF equipment performance maps, which can be used for energy simulations in TRNSYS and EnergyPlus, etc. In the study, the major independent variables for mapping are identified and the deviations between the simplified performance map and the actual equipment system simulation are quantified.

Shen, Bo [ORNL; Rice, C Keith [ORNL

2012-01-01T23:59:59.000Z

186

Opportunities for Energy Efficiency and Automated Demand Response in Industrial Refrigerated Warehouses in California  

E-Print Network (OSTI)

system. The refrigeration system design involves sizing ofDesign Essentials for Refrigerated Storage Facilities, American Society for Heating Refrigeration anddesign considerations are mostly related to wall and roof types, shell insulation, and the refrigeration

Lekov, Alex

2009-01-01T23:59:59.000Z

187

Comparison of Several Eco-Friendly Refrigeration Technologies  

E-Print Network (OSTI)

In this paper, the operation principles, thermodynamics characteristics, and technical practicability were compared between thermoelectric refrigeration, magnetic refrigeration and adsorption refrigeration. The TE refrigeration is the most well-developed, applicable and competitive technology. Three eco-friendly refrigeration systems are increasingly getting attention, especially in a day with increasingly energy and environmental crises. In summary, thermoelectric refrigeration possesses the following superiorities: a longer developmental period, more perfect techniques, increasing applications, a larger range of refrigerating capacity, and a better economic property in small refrigerating capacity. Thermoelectric refrigeration cannot be replaced in special fields, and its applications have received more and more attention in recovering waste heat. Magnetic refrigeration has been widely applied in lower temperature regions; its application in middle temperature regions is juvenile. In particular, there is no application of this technique in high temperature regions. Adsorption refrigeration is practical only in near room temperatures. Its advantage is that it can be used in some fields where conventional refrigeration cannot be applied, such as in the application of solar energy, geothermal energy, and other renewable energy, and the recovery of residual and waste heat.? Supported by the Young Foundation of Central South University of Forestry & Technology (06002A) The disadvantages are as follows: the cost is expensive, no practical technique is available at present, and thus, it possesses no general superiority versus other refrigeration technologies.

Tang, C.; Luo, Q.; Li, X.; Zhu, X.

2006-01-01T23:59:59.000Z

188

Potential Refrigerants for Power Electronics Cooling  

DOE Green Energy (OSTI)

In the past, automotive refrigerants have conventionally been used solely for the purpose of air conditioning. However, with the development of hybrid-electric vehicles and the incorporation of power electronics (PEs) into the automobile, automotive refrigerants are taking on a new role. Unfortunately, PEs have lifetimes and functionalities that are highly dependent on temperature and as a result thermal control plays an important role in the performance of PEs. Typically, PEs are placed in the engine compartment where the internal combustion engine (ICE) already produces substantial heat. Along with the ICE heat, the additional thermal energy produced by PEs themselves forces designers to use different cooling methods to prevent overheating. Generally, heat sinks and separate cooling loops are used to maintain the temperature. Disturbingly, the thermal control system can consume one third of the total volume and may weigh more than the PEs [1]. Hence, other avenues have been sought to cool PEs, including submerging PEs in automobile refrigerants to take advantage of two-phase cooling. The objective of this report is to explore the different automotive refrigerants presently available that could be used for PE cooling. Evaluation of the refrigerants will be done by comparing environmental effects and some thermo-physical properties important to two-phase cooling, specifically measuring the dielectric strengths of potential candidates. Results of this report will be used to assess the different candidates with good potential for future use in PE cooling.

Starke, M.R.

2005-10-24T23:59:59.000Z

189

Energy Consumption of Refrigerators in Ghana - Outcomes of Household  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Consumption of Refrigerators in Ghana - Outcomes of Household Energy Consumption of Refrigerators in Ghana - Outcomes of Household Surveys Speaker(s): Essel Ben Hagan Date: July 12, 2007 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Robert Van Buskirk Galen Barbose As part of activities to develop refrigerator efficiency standards regulations in Ghana, a national survey on the energy consumption of refrigerators and refrigerator-freezers has been conducted. The survey covered 1000 households in urban, peri-urban and rural communities in various parts of the country. The survey found that, on average, refrigerators and refrigerator-freezers in Ghana use almost three times what is allowed by minimum efficiency standards in the U.S., and a few refrigerators had energy use at levels almost ten times the U.S.

190

Loveland Water and Power - Refrigerator Recycling Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Refrigerator Recycling Program Refrigerator Recycling Program Loveland Water and Power - Refrigerator Recycling Program < Back Eligibility Residential Savings Category Appliances & Electronics Maximum Rebate Limit one rebate per account per year Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Refrigerator and Freezer Recycling: $35 Loveland Water and Power is providing an incentive for its customers to recycle their old refrigerators. Interested customers can call the utility to arrange a time to pick up the old refrigerator. The old refrigerator should be brought outside but remain plugged in so the utility can make it is in working condition. the utility will then take the refrigerator to a recycling facility and issue a $35 bill credit. Other Information

191

Refrigerator Standards Save Consumers $ Billions | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Refrigerator Standards Save Consumers $ Billions Refrigerator Standards Save Consumers $ Billions Refrigerator Standards Save Consumers $ Billions March 5, 2013 - 10:35am Addthis Refrigerator Standards Refrigerator Standards Refrigerator technology has come a long way since Dr. John Gorrie (1803 - 1855), a forward-looking inventor, was granted U. S. Patent #8080 for mechanical refrigeration in 1851. In those days, ice was expensive, if it was even available: Blocks of natural ice were carved from frozen lakes and rivers and stored in special warehouses under layers of sawdust for insulation. By the 1890s, pollution and sewage dumping caused by population growth compromised sources of pure, natural ice, threatening the brewing, meat-packing, and dairy industries. As these and other industries sought better solutions, modern refrigeration technology started to evolve.

192

DOE Resolves Avanti Refrigerator and Freezer Civil Penalty Case  

Energy.gov (U.S. Department of Energy (DOE))

Today, the Department of Energy announced that it has resolved the civil penalty action against Mackle Company for its failure to certify that refrigerators and refrigerator-freezers sold under the...

193

VEE-0079 - In the Matter of Diversified Refrigeration, Inc.  

Energy.gov (U.S. Department of Energy (DOE))

Diversified Refrigeration, Inc. (DRI) requests a six-month exception from the 2001 energy appliance efficiency standards for built-in refrigerators that become effective July 1, 2001. As explained...

194

Integrating giant microwave absorption with magnetic refrigeration in one  

E-Print Network (OSTI)

Integrating giant microwave absorption with magnetic refrigeration in one multifunctional with magnetic refrigeration in one multifunctional material. This integration not only advances our EMI problem, it is becoming very urgent to design and fabricate the electromagnetic compatibility (EMC

Wang, Wei Hua

195

Thermoelectric refrigerator having improved temperature-stabilization means  

DOE Patents (OSTI)

A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized.

Falco, C.M.

1981-07-29T23:59:59.000Z

196

Proposed Methodology for LEED Baseline Refrigeration Modeling (Presentation)  

SciTech Connect

This PowerPoint presentation summarizes a proposed methodology for LEED baseline refrigeration modeling. The presentation discusses why refrigeration modeling is important, the inputs of energy models, resources, reference building model cases, baseline model highlights, example savings calculations and results.

Deru, M.

2011-02-01T23:59:59.000Z

197

International Refrigeration: Proposed Penalty (2012-CE-1510)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

International Refrigeration Products International Refrigeration Products (room air conditioners) ) ) ) ) ) Case Number: 2012-CE-1510 NOTICE OF PROPOSED CIVIL PENALTY Date issued: July 9, 2012 Number of alleged violations: 5475 (365 days, 15 models) Maximum possible assessment: $1,095,000 Proposed civil penalty: $109,500 The U.S. Department of Energy ("DOE") Office of the General Counsel, Office of Enforcement, alleges that International Refrigeration Products ("IRP") has violated cettain provisions of the Energy Policy and Conservation Act, 42 U.S.C. § 6291 et seq. ("the Act"), and 10 C.P.R. § 429.12. Specifically, DOE alleges: 1. IRP has manufactured 1 a variety of Sea Breeze brand room air conditioners, including basic models WA46YR, WA48YRX, WA410YRX, WA412YRX, WH418ZRX,

198

Of Refrigerators & Regulations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Of Refrigerators & Regulations Of Refrigerators & Regulations Of Refrigerators & Regulations February 8, 2011 - 9:29am Addthis Jesse Lee White House Director of Online Affairs Editor's Note: This entry has been cross-posted from The White House Blog. For those interested in the President's remarks to the U.S. Chamber of Commerce and his views on the shared responsibilities of government and business to the American people, our post earlier will give a suitable overview. For those interested in the details of the President's Executive Order on reviewing regulations and their impacts on the economy, Cass Sunstein's post this morning will also be of value. But the President also took a moment during his speech to put the debate over regulation in a different perspective, and to break through the false dichotomy so often

199

Energy Saving with Absorption Refrigeration Technologies  

E-Print Network (OSTI)

Absorption refrigeration technology can be an economical and cost effective means of reducing energy cost and/or improving the efficiency and output of your process. We believe the potential benefits of absorption refrigeration technology have generally been overlooked by the process industry. This paper will address the application of the lithium bromide-water cycle in various energy saving modes. A waste heat powered absorption chiller producing chilled water can reduce energy consumption in a process plant by replacing an existing mechanical refrigeration system or replacing cooling tower water with a lower temperature cooling medium at negligible increase in energy cost. A variety of waste heat sources can be used at temperatures as low as 150 F.

Davis, R. C.

1984-01-01T23:59:59.000Z

200

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

... Is this refrigerator model suitable for frozen vaccine storage? Freezer thermostat dial set to midpoint position: vaccine vial temperatures ...

2012-08-02T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

High Efficiency Low Emission Supermarket Refrigeration Research Project  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy (DOE) is currently conducting research into high efficiency, low emission supermarket refrigeration technologies.

202

Toxicity Data to Determine Refrigerant Concentration Limits  

SciTech Connect

This report reviews toxicity data, identifies sources for them, and presents resulting exposure limits for refrigerants for consideration by qualified parties in developing safety guides, standards, codes, and regulations. It outlines a method to calculate an acute toxicity exposure limit (ATEL) and from it a recommended refrigerant concentration limit (RCL) for emergency exposures. The report focuses on acute toxicity with particular attention to lethality, cardiac sensitization, anesthetic and central nervous system effects, and other escape-impairing effects. It addresses R-11, R-12, R-22, R-23, R-113, R-114, R-116, R-123, R-124, R-125, R-134, R-134a, R-E134, R-141b, R-142b, R-143a, R-152a, R-218, R-227ea, R-236fa, R-245ca, R-245fa, R-290, R-500, R-502, R-600a, R-717, and R-744. It summarizes additional data for R-14, R-115, R-170 (ethane), R-C318, R-600 (n-butane), and R-1270 (propylene) to enable calculation of limits for blends incorporating them. The report summarizes the data a nd related safety information, including classifications and flammability data. It also presents a series of tables with proposed ATEL and RCL concentrations-in dimensionless form and the latter also in both metric (SI) and inch-pound (IP) units of measure-for both the cited refrigerants and 66 zerotropic and azeotropic blends. They include common refrigerants, such as R-404A, R-407C, R-410A, and R-507A, as well as others in commercial or developmental status. Appendices provide profiles for the cited single-compound refrigerants and for R-500 and R-502 as well as narrative toxicity summaries for common refrigerants. The report includes an extensive set of references.

Calm, James M.

2000-09-30T23:59:59.000Z

203

Design of a scanning gate microscope in a cryogen-free dilution refrigerator  

E-Print Network (OSTI)

We report on our design of a scanning gate microscope housed in a cryogen-free dilution refrigerator with a base temperature of 15 mK. The recent increase in efficiency of pulse tube cryocoolers has made cryogen-free systems popular in recent years. However, this new style of cryostat presents challenges for performing scanning probe measurements, mainly as a result of the vibrations introduced by the cryocooler. We demonstrate scanning with root-mean-square vibrations of 0.8 nm at 3 K and 2.1 nm at 15 mK in a 1 kHz bandwidth with our design.

Pelliccione, Matthew; Bartel, John; Keller, Andrew; Goldhaber-Gordon, David

2012-01-01T23:59:59.000Z

204

ENVIRONMENTAL ASSESSMENT FOR THE PROPOSED ENERGY CONSERVATION STANDARD FOR REFRIGERATORS, REFRIGERATOR-  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ASSESSMENT FOR THE PROPOSED ENERGY ASSESSMENT FOR THE PROPOSED ENERGY CONSERVATION STANDARD FOR REFRIGERATORS, REFRIGERATOR- , AND FREEZERS - 1. INTRODUCTION AND NEED FOR PROPOSED ACTION ental Assessment (EA) on the candidate energy conservation stand licy Act. of 1969 (NEPA), regulations of the Council on Environmentd Qu refrigerators, re€iigerator-freezers, and freezers was prepared pursuant to the National ' ederal Regulations, Parts 1500 through. 1508. The proposed energy conservation standard (Level 1) and the alternative standards are being reviewed in an energy- efficiency standards rulemaking that the Department has undertaken pursuant to the Energy Policy and Conservation Act, as amended by the National Energy Conservation Policy Act and the National Appliance Energy Consehation Act

205

Retrofitting Doors on Open Refrigerated Cases  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Retrofitting Doors on Open Retrofitting Doors on Open Refrigerated Cases William Goetzler Navigant Consulting, Inc. wgoetzler@navigant.com (781) 270-8351 April 4, 2013 BBA Refrigeration Project Team Images courtesy of REMIS AMERICA, LLC. 2 | Building Technologies Office eere.energy.gov Technology Overview Image from Investigation of Energy- Efficient Supermarket Display Cases. 2004, Oak Ridge National Laboratory. Background and Motivation * Adding doors to open cases (retrofits) greatly reduces cold air loss - 50-80% load reduction - Load reduction = system energy savings

206

Reducing the Carbon Footprint of Commercial Refrigeration Systems Using Life Cycle Climate Performance Analysis: From System Design to Refrigerant Options  

SciTech Connect

In this paper, Life Cycle Climate Performance (LCCP) analysis is used to estimate lifetime direct and indirect carbon dioxide equivalent gas emissions of various refrigerant options and commercial refrigeration system designs, including the multiplex DX system with various hydrofluorocarbon (HFC) refrigerants, the HFC/R744 cascade system incorporating a medium-temperature R744 secondary loop, and the transcritical R744 booster system. The results of the LCCP analysis are presented, including the direct and indirect carbon dioxide equivalent emissions for each refrigeration system and refrigerant option. Based on the results of the LCCP analysis, recommendations are given for the selection of low GWP replacement refrigerants for use in existing commercial refrigeration systems, as well as for the selection of commercial refrigeration system designs with low carbon dioxide equivalent emissions, suitable for new installations.

Fricke, Brian A [ORNL; Abdelaziz, Omar [ORNL; Vineyard, Edward Allan [ORNL

2013-01-01T23:59:59.000Z

207

ASHRAE/NIST Refrigerants Conference International concerns about the impact of refrigerants on climate change drive the  

E-Print Network (OSTI)

ASHRAE/NIST Refrigerants Conference International concerns about the impact of refrigerants conference between ASHRAE and NIST. Supporting Organizations: NOTE: Registration closes Oct. 18 and includes conference proceedings, daily lunch and dinner Monday evening. ASHRAE Members: $425 Non

Fernández-Juricic, Esteban

208

Refrigeration needs for sustainable preservation of horticultural products  

Science Conference Proceedings (OSTI)

Fresh horticultural products are highly perishable and need refrigeration for further preservation. Refrigeration needs energy consumption with consequent economical cost and damage for the environment. The objective of the present work was to use efficiently ... Keywords: energy efficiency, food salads, halophytes, postharvest technologies, refrigeration, safe food, sustainability

Custódia Gago; Ana Rita Sousa; Miriam Julião; Graça Miguel; Dulce Antunes; Thomas Panagopoulos

2011-02-01T23:59:59.000Z

209

HANDLING FRESH FISH REFRIGERATION OF FISH -PART 2  

E-Print Network (OSTI)

(Fishery Leaflet 427) Cold-Storage Design and Refrigeration Equipment Part 3 (Fisher y Leaflet 429) FactorsHANDLING FRESH FISH REFRIGERATION OF FISH - PART 2 UNITED STATES DEPARTMENT OF THE INTERIOR FISH 428 Washington 25, D, C. December 1956 REFRIGERATION OF FISH - PART TWO HANDLING FRESH FISH By Charles

210

Carbon Dioxide and Ionic Liquid Refrigerants: Compact, Efficient Air Conditioning with Ionic Liquid-Based Refrigerants  

SciTech Connect

BEETIT Project: Notre Dame is developing an air-conditioning system with a new ionic liquid and CO2 as the working fluid. Synthetic refrigerants used in air conditioning and refrigeration systems are potent GHGs and can trap 1,000 times more heat in the atmosphere than CO2 alone—making CO2 an attractive alternative for synthetic refrigerants in cooling systems. However, operating cooling systems with pure CO2 requires prohibitively high pressures and expensive hardware. Notre Dame is creating a new fluid made of CO2 and ionic liquid that enables the use of CO2 at low pressures and requires minimal changes to existing hardware and production lines. This new fluid also produces no harmful emissions and can improve the efficiency of air conditioning systems— enabling new use of CO2 as a refrigerant in cooling systems.

2010-10-01T23:59:59.000Z

211

Floating Loop System For Cooling Integrated Motors And Inverters Using Hot Liquid Refrigerant  

DOE Patents (OSTI)

A floating loop vehicle component cooling and air-conditioning system having at least one compressor for compressing cool vapor refrigerant into hot vapor refrigerant; at least one condenser for condensing the hot vapor refrigerant into hot liquid refrigerant by exchanging heat with outdoor air; at least one floating loop component cooling device for evaporating the hot liquid refrigerant into hot vapor refrigerant; at least one expansion device for expanding the hot liquid refrigerant into cool liquid refrigerant; at least one air conditioning evaporator for evaporating the cool liquid refrigerant into cool vapor refrigerant by exchanging heat with indoor air; and piping for interconnecting components of the cooling and air conditioning system.

Hsu, John S [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN; Coomer, Chester [Knoxville, TN; Marlino, Laura D [Oak Ridge, TN

2006-02-07T23:59:59.000Z

212

Anodization of process tubes  

SciTech Connect

This report discusses the presence of corrosion products upon aluminum process tubes removed from wet portions of F Pile which led to the suspicion that the tubes might be corroding at an accelerated rate because of water entrapped in the channels between the tubes and the graphite blocks. Corrosion was especially noted on those tubes that were tightly stuck within the blocks. Analysis of the corrosion products showed that the major constituent was a hydrated aluminum oxide, containing iron oxide, calcium carbonate, and other substances in lower concentrations. This led to placement of an order for the anodizing of 200 process tubes.

Pitzer, E.C.

1952-09-17T23:59:59.000Z

213

The smallest refrigerators can reach maximal efficiency  

E-Print Network (OSTI)

We investigate whether size imposes a fundamental constraint on the efficiency of small thermal machines. We analyse in detail a model of a small self-contained refrigerator consisting of three qubits. We show analytically that this system can reach the Carnot efficiency, thus demonstrating that there exists no complementarity between size and efficiency.

Paul Skrzypczyk; Nicolas Brunner; Noah Linden; Sandu Popescu

2010-09-04T23:59:59.000Z

214

Refrigeration in a world without CFCs  

Science Conference Proceedings (OSTI)

In an era of heightened awareness of energy efficiency and the associated environmental impacts, many industries, worldwide, are exploring ``environmentally friendly`` technologies that provide equivalent or improved performance while reducing or eliminating harmful side effects. The refrigeration and air conditioning industry, due to its reliance on CFCs and HCFCs has invested in research in alternatives to the industry standard vapor compression machines. One alternative technology with great promise is chemical absorption. Absorption chillers offer comparable refrigeration output with reduced SO{sub 2}, CO{sub 2}, and NO{sub x} emissions. Additionally, absorption chillers do not use CFCs or HCFCs, refrigerants that contribute to ozone depletion and global warming. The purpose of this paper is to provide an introduction for those new to absorption technology as well as a discussion of selected high efficiency cycles and environmental impacts for those familiar with absorption. The introduction will include a brief history of absorption and a description of the basic refrigeration cycle, while the advanced sections will discuss triple-effect technology and a life-cycle or ``systems`` approach to evaluating global warming impacts.

Garland, R.W. [U.S. Dept. of Energy, Washington D.C. (United States); Adcock, P.W. [Oak Ridge National Lab., TN (United States)

1996-09-01T23:59:59.000Z

215

Waste Heat Recapture from Supermarket Refrigeration Systems  

DOE Green Energy (OSTI)

The objective of this project was to determine the potential energy savings associated with improved utilization of waste heat from supermarket refrigeration systems. Existing and advanced strategies for waste heat recovery in supermarkets were analyzed, including options from advanced sources such as combined heat and power (CHP), micro-turbines and fuel cells.

Fricke, Brian A [ORNL

2011-11-01T23:59:59.000Z

216

On the performance of ejector refrigeration systems  

Science Conference Proceedings (OSTI)

The design characteristics of an ejector refrigeration system using R134a with fixed cooling capacity and fixed inlet temperatures of the external fluids at the inlet of the generator, the condenser and the evaporator are presented for different pressures ... Keywords: COP, R-134a, computer simulation, finite size thermodynamics

Abdelouahid Dahmani; Zine Aidoun; Nicolas Galanis

2010-02-01T23:59:59.000Z

217

International Refrigeration: Proposed Penalty (2012-CE-1510) | Department  

NLE Websites -- All DOE Office Websites (Extended Search)

International Refrigeration: Proposed Penalty (2012-CE-1510) International Refrigeration: Proposed Penalty (2012-CE-1510) International Refrigeration: Proposed Penalty (2012-CE-1510) July 9, 2012 DOE alleged in a Notice of Proposed Civil Penalty that International Refrigeration Products failed to certify a various room air conditioners as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. International Refrigeration: Proposed Penalty (2012-CE-1510) More Documents & Publications

218

Building Technologies Office: Low-Global Warming Potential Refrigerants  

NLE Websites -- All DOE Office Websites (Extended Search)

Low-Global Warming Low-Global Warming Potential Refrigerants Research Project to someone by E-mail Share Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Facebook Tweet about Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Twitter Bookmark Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Google Bookmark Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Delicious Rank Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Digg Find More places to share Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on AddThis.com... About Take Action to Save Energy

219

Dilution cycle control for an absorption refrigeration system  

DOE Patents (OSTI)

A dilution cycle control system for an absorption refrigeration system is disclosed. The control system includes a time delay relay for sensing shutdown of the absorption refrigeration system and for generating a control signal only after expiration of a preselected time period measured from the sensed shutdown of the absorption refrigeration system, during which the absorption refrigeration system is not restarted. A dilution cycle for the absorption refrigeration system is initiated in response to generation of a control signal by the time delay relay. This control system is particularly suitable for use with an absorption refrigeration system which is frequently cycled on and off since the time delay provided by the control system prevents needless dilution of the absorption refrigeration system when the system is turned off for only a short period of time and then is turned back on.

Reimann, Robert C. (Lafayette, NY)

1984-01-01T23:59:59.000Z

220

Suction-recirculation device for stabilizing particle flows within a solar powered solid particle receiver  

DOE Patents (OSTI)

A suction-recirculation device for stabilizing the flow of a curtain of blackened heat absorption particles falling inside of a solar receiver with an open aperture. The curtain of particles absorbs the concentrated heat from a solar mirror array reflected up to the receiver on a solar power tower. External winds entering the receiver at an oblique angle can destabilize the particle curtain and eject particles. A fan and ductwork is located behind the back wall of the receiver and sucks air out through an array of small holes in the back wall. Any entrained particles are separated out by a conventional cyclone device. Then, the air is recirculated back to the top of the receiver by injecting the recycled air through an array of small holes in the receiver's ceiling and upper aperture front wall. Since internal air is recirculated, heat losses are minimized and high receiver efficiency is maintained. Suction-recirculation velocities in the range of 1-5 m/s are sufficient to stabilize the particle curtain against external wind speeds in excess of 10 m/s.

Kolb, Gregory J. (Albuquerque, NM)

2012-02-07T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Suction-recirculation device for stabilizing particle flows within a solar powered solid particle receiver  

SciTech Connect

A suction-recirculation device for stabilizing the flow of a curtain of blackened heat absorption particles falling inside of a solar receiver with an open aperture. The curtain of particles absorbs the concentrated heat from a solar mirror array reflected up to the receiver on a solar power tower. External winds entering the receiver at an oblique angle can destabilize the particle curtain and eject particles. A fan and ductwork is located behind the back wall of the receiver and sucks air out through an array of small holes in the back wall. Any entrained particles are separated out by a conventional cyclone device. Then, the air is recirculated back to the top of the receiver by injecting the recycled air through an array of small holes in the receiver's ceiling and upper aperture front wall. Since internal air is recirculated, heat losses are minimized and high receiver efficiency is maintained. Suction-recirculation velocities in the range of 1-5 m/s are sufficient to stabilize the particle curtain against external wind speeds in excess of 10 m/s.

Kolb, Gregory J. (Albuquerque, NM)

2012-02-07T23:59:59.000Z

222

Conduction cooled tube supports  

DOE Patents (OSTI)

In boilers, process tubes are suspended by means of support studs that are in thermal contact with and attached to the metal roof casing of the boiler and the upper bend portions of the process tubes. The support studs are sufficiently short that when the boiler is in use, the support studs are cooled by conduction of heat to the process tubes and the roof casing thereby maintaining the temperature of the stud so that it does not exceed 1400.degree. F.

Worley, Arthur C. (Mt. Tabor, NJ); Becht, IV, Charles (Morristown, NJ)

1984-01-01T23:59:59.000Z

223

Coiled Tubing Safety Manual  

SciTech Connect

This document addresses safety concerns regarding the use of coiled tubing as it pertains to the preservation of personnel, environment and the wellbore.

Crow, W.

1999-04-06T23:59:59.000Z

224

Wound tube heat exchanger  

DOE Patents (OSTI)

What is disclosed is a wound tube heat exchanger in which a plurality of tubes having flattened areas are held contiguous adjacent flattened areas of tubes by a plurality of windings to give a double walled heat exchanger. The plurality of windings serve as a plurality of effective force vectors holding the conduits contiguous heat conducting walls of another conduit and result in highly efficient heat transfer. The resulting heat exchange bundle is economical and can be coiled into the desired shape. Also disclosed are specific embodiments such as the one in which the tubes are expanded against their windings after being coiled to insure highly efficient heat transfer.

Ecker, Amir L. (Duncanville, TX)

1983-01-01T23:59:59.000Z

225

Photomultiplier tube saturation indicator  

DOE Patents (OSTI)

A photomultiplier tube saturation indicator is formed by supplying a supplemental light source, typically a light emitting diode (LED), adjacent to the photomultiplier tube. A switch allows the light source to be activated. The light is forwarded to the photomultiplier tube by an optical fiber. If the probe is properly light tight, then a meter attached to the indicator will register the light from the LED. If the probe is no longer light tight, and the saturation indicator is saturated, no signal will be registered when the LED is activated. This photomultiplier tube is used with alpha contamination probes.

Ruch, J.F.; Urban, D.J.

1995-12-31T23:59:59.000Z

226

Preliminary selection of refrigerants for dual-circuit and Lorenz refrigerator/freezers  

SciTech Connect

The paper discusses the preliminary selection of refrigerants for dual-circuit and Lorenz refrigerator/freezers (RFs). Since RFs currently use a fully halogenated chlorofluorocarbon (CFC) as a refrigerant and are the most energy-consuming appliances in most households in the U.S., EPA is concerned about not only RFs' effects on stratospheric ozone depletion but also their impact on the greenhouse effect. Reductions in power consumption will slow the increase in carbon dioxide (CO{sub 2}) concentrations in the atmosphere by reducing the utility companies' need for capacity. CO{sub 2} concentrations are believed to be directly related to impacts of the greenhouse effect. For these reasons, EPA believes that finding the most energy-efficient refrigerant(s) and RF design is important when eliminating fully halogenated CFCs. Two new configurations (the dual-circuit and Lorenz RFs) appear to provide energy savings of up to 20% over standard U.S. RF designs.

Bare, J.C.

1990-01-01T23:59:59.000Z

227

International Refrigeration: Order (2012-CE-1510)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

WASHINGTON, D.C. 20585 WASHINGTON, D.C. 20585 Case Number: 2012-CE-1510 International Refrigeration Products, Respondent ) ) ) ) ) ) ORDER Issued: July 20, 2012 By the General Counsel, U.S. Department of Energy: 1. In this Order, I adopt the attached Compromise Agreement entered into between the U.S. Department of Energy ("DOE") and International Refrigeration Products ("Respondent"). The Compromise Agreement resolves the case initiated to pursue a civil penalty for violations of the compliance certification requirements located at 10 C.P.R. § 429.12. 2. DOE and Respondent have negotiated the terms of the Compromise Agreement that resolve this matter. A copy of the Compromise Agreement is attached hereto and incorporated by reference. 3. After reviewing the terms of the Compromise Agreement and evaluating the facts

228

Performance bound for quantum absorption refrigerators  

E-Print Network (OSTI)

An implementation of quantum absorption chillers with three qubits has been recently proposed, that is ideally able to reach the Carnot performance regime. Here we study the working efficiency of such self-contained refrigerators, adopting a consistent treatment of dissipation effects. We demonstrate that the coefficient of performance at maximum cooling power is upper bounded by 3/4 of the Carnot performance. The result is independent of the details of the system and the equilibrium temperatures of the external baths. We provide design prescriptions that saturate the bound in the limit of a large difference between the operating temperatures. Our study suggests that delocalized dissipation, which must be taken into account for a proper modelling of the machine-baths interaction, is a fundamental source of irreversibility which prevents the refrigerator from approaching the Carnot performance arbitrarily closely in practice. The potential role of quantum correlations in the operation of these machines is also investigated.

Luis A. Correa; José P. Palao; Gerardo Adesso; Daniel Alonso

2012-12-18T23:59:59.000Z

229

SCREW COMPRESSOR CHARACTERISTICS FOR HELIUM REFRIGERATION SYSTEMS  

SciTech Connect

The oil injected screw compressors have practically replaced all other types of compressors in modern helium refrigeration systems due to their large displacement capacity, minimal vibration, reliability and capability of handling helium's high heat of compression.At the present state of compressor system designs for helium systems, typically two-thirds of the lost input power is due to the compression system. Therefore it is important to understand the isothermal and volumetric efficiencies of these machines to help properly design these compression systems to match the refrigeration process. This presentation summarizes separate tests that have been conducted on Sullair compressors at the Superconducting Super-Collider Laboratory (SSCL) in 1993, Howden compressors at Jefferson Lab (JLab) in 2006 and Howden compressors at the Spallation Neutron Source (SNS) in 2006. This work is part of an ongoing study at JLab to understand the theoretical basis for these efficiencies and their loss

Ganni, Venkatarao; Knudsen, Peter; Creel, Jonathan; Arenius, Dana; Casagrande, Fabio; Howell, Matt

2008-03-01T23:59:59.000Z

230

Steam generator tube failures  

SciTech Connect

A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

1996-04-01T23:59:59.000Z

231

Improving Industrial Refrigeration System Efficiency - Actual Applications  

E-Print Network (OSTI)

This paper discusses actual design and modifications for increased system efficiency and includes reduced chilled liquid flow during part load operation, reduced condensing and increased evaporator temperatures for reduced system head, thermosiphon cycle cooling during winter operation, compressor intercooling, direct refrigeration vs. brine cooling, insulation of cold piping to reduce heat gain, multiple screw compressors for improved part load operation, evaporative condensers for reduced system head and pumping energy, and using high efficiency motors.

White, T. L.

1980-01-01T23:59:59.000Z

232

Development of Low Global Warming Potential Refrigerant Solutions for Commercial Refrigeration Systems using a Life Cycle Climate Performance Design Tool  

SciTech Connect

Commercial refrigeration systems are known to be prone to high leak rates and to consume large amounts of electricity. As such, direct emissions related to refrigerant leakage and indirect emissions resulting from primary energy consumption contribute greatly to their Life Cycle Climate Performance (LCCP). In this paper, an LCCP design tool is used to evaluate the performance of a typical commercial refrigeration system with alternative refrigerants and minor system modifications to provide lower Global Warming Potential (GWP) refrigerant solutions with improved LCCP compared to baseline systems. The LCCP design tool accounts for system performance, ambient temperature, and system load; system performance is evaluated using a validated vapor compression system simulation tool while ambient temperature and system load are devised from a widely used building energy modeling tool (EnergyPlus). The LCCP design tool also accounts for the change in hourly electricity emission rate to yield an accurate prediction of indirect emissions. The analysis shows that conventional commercial refrigeration system life cycle emissions are largely due to direct emissions associated with refrigerant leaks and that system efficiency plays a smaller role in the LCCP. However, as a transition occurs to low GWP refrigerants, the indirect emissions become more relevant. Low GWP refrigerants may not be suitable for drop-in replacements in conventional commercial refrigeration systems; however some mixtures may be introduced as transitional drop-in replacements. These transitional refrigerants have a significantly lower GWP than baseline refrigerants and as such, improved LCCP. The paper concludes with a brief discussion on the tradeoffs between refrigerant GWP, efficiency and capacity.

Abdelaziz, Omar [ORNL; Fricke, Brian A [ORNL; Vineyard, Edward Allan [ORNL

2012-01-01T23:59:59.000Z

233

DOE Opens Three Investigations into Alleged Refrigerator Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Opens Three Investigations into Alleged Refrigerator Efficiency Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations April 12, 2010 - 7:27pm Addthis The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that failed to meet federal energy efficiency standards. Under the subpoena, Arçelik A.S, a Turkish Company is required to submit detailed information about the design, marketing and U.S. sales of its Blomberg brand refrigerator-freezer, model "BRFB1450." The Department also requested testing data from Whirlpool Corporation and Viking Range Corporation for two refrigerator-freezers that the companies

234

Could You Save Money on Your Refrigerator? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? July 20, 2012 - 4:35pm Addthis Earlier this week, Amanda wrote about how you can save energy by choosing the right refrigerator and using it efficiently. These tips explain all sorts of ways you can ensure your refrigerator uses as little energy as possible to keep itself cool. So this week, we're curious: Could you save money with your refrigerator? You have the chance to share your thoughts on a question about energy efficiency or renewable energy for consumers. E-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov. Addthis Related Articles How Do You Save Money on Summer Holidays? Have You Seen Energy Efficiency Improvements in Your Neighborhood?

235

DOE Opens Three Investigations into Alleged Refrigerator Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Opens Three Investigations into Alleged Refrigerator Efficiency Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations April 12, 2010 - 7:27pm Addthis The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that failed to meet federal energy efficiency standards. Under the subpoena, Arçelik A.S, a Turkish Company is required to submit detailed information about the design, marketing and U.S. sales of its Blomberg brand refrigerator-freezer, model "BRFB1450." The Department also requested testing data from Whirlpool Corporation and Viking Range Corporation for two refrigerator-freezers that the companies

236

Could You Save Money on Your Refrigerator? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? July 20, 2012 - 4:35pm Addthis Earlier this week, Amanda wrote about how you can save energy by choosing the right refrigerator and using it efficiently. These tips explain all sorts of ways you can ensure your refrigerator uses as little energy as possible to keep itself cool. So this week, we're curious: Could you save money with your refrigerator? You have the chance to share your thoughts on a question about energy efficiency or renewable energy for consumers. E-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov. Addthis Related Articles How Do You Save Money on Summer Holidays? Have You Seen Energy Efficiency Improvements in Your Neighborhood?

237

Method of reducing chlorofluorocarbon refrigerant emissons to the atmosphere  

DOE Patents (OSTI)

A method is disclosed for reducing chloroflurocarbon (CFC) refrigerant emissions during removal or transfer or refrigerants from a vapor compression cooling system or heat pump which comprises contacting the refrigerant with a suitable sorbent material. The sorbent material allows for the storage and retention or the chlorofluorocarbon in non-gaseous form so that it does not tend to escape to the atmosphere where it would cause harm by contributing to ozone depletion. In other aspects of the invention, contacting of CFC refrigerants with sorbent material allows for purification and recycling of used refrigerant, and a device containing stored sorbent material can be employed in the detection of refrigerant leakage in a cooling system or heat pump.

DeVault, Robert C. (Knoxville, TN); Fairchild, Phillip D. (Clinton, TN); Biermann, Wendell J. (Fayetteville, NY)

1990-01-01T23:59:59.000Z

238

Optimal Design Refrigeration System for a Mucilage Glue Fiber Factory  

E-Print Network (OSTI)

In a mucilage glue fiber factory, the design of the refrigeration system takes into account the characteristics of mucilage glue fiber production and fully uses the refrigeration compressor heat to economize energy and reduce the production cost. In this paper, the author introduces different points of this kind of design with conventional design. For efficient use of the compressed heat of the refrigeration system, the designer should calculate the number of condensers according to the changes that the refrigeration system undergoes after using the soft water as cooling water. To economize the investment, the designer should use the refrigeration workshop and the soft water workshop and obtain optimum processing to shorten the duct. Through an economizing energy analysis, the paper demonstrates that an optimum design for a refrigeration system for a mucilage glue factory has a significant energy saving potential.

Tan, C.; Liu, J.; Tang, F.; Liu, Y.

2006-01-01T23:59:59.000Z

239

Japanese Refrigerators : A Field Performance Analysis : Summary Report.  

SciTech Connect

Society generally expects Japanese refrigerators to be more energy efficient than their American-made counterparts. With increasing attention being focused on appliance energy efficiency, research into operating characteristics of Japanese refrigerators has gained importance. Other projects report the monitored energy use of certain models of Japanese refrigerators. In addition, laboratory tests determined energy consumption of certain refrigerators under controlled conditions. In 1987, Bonneville Power Administration (BPA) undertook a project to measure and analyze the energy consumption of 12 Japanese-made refrigerators in the Portland-Vancouver metropolitan area. This project's purpose was to collect field data on certain models and compare with that collected in other projects and laboratory tests. Japanese energy consumption figures fall 30--40% below those of DOE. This energy savings, if real, could substantially cut baseload power for utilities. Determining typical refrigerator energy use patterns and which environmental factors effect them helps utilities to forecast demand. 7 refs., 1 fig., 1 tab.

Short, John A.

1990-02-01T23:59:59.000Z

240

Air Conditioning with Magnetic Refrigeration : An Efficient, Green Compact Cooling System Using Magnetic Refrigeration  

SciTech Connect

BEETIT Project: Astronautics is developing an air conditioning system that relies on magnetic fields. Typical air conditioners use vapor compression to cool air. Vapor compression uses a liquid refrigerant to circulate within the air conditioner, absorb the heat, and pump the heat out into the external environment. Astronautics’ design uses a novel property of certain materials, called “magnetocaloric materials”, to achieve the same result as liquid refrigerants. These magnetocaloric materials essentially heat up when placed within a magnetic field and cool down when removed, effectively pumping heat out from a cooler to warmer environment. In addition, magnetic refrigeration uses no ozone-depleting gases and is safer to use than conventional air conditioners which are prone to leaks.

None

2010-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Active magnetic refrigerants based on Gd-Si-Ge material and refrigeration apparatus and process  

DOE Patents (OSTI)

Active magnetic regenerator and method using Gd.sub.5 (Si.sub.x Ge.sub.1-x).sub.4, where x is equal to or less than 0.5, as a magnetic refrigerant that exhibits a reversible ferromagnetic/antiferromagnetic or ferromagnetic-II/ferromagnetic-I first order phase transition and extraordinary magneto-thermal properties, such as a giant magnetocaloric effect, that renders the refrigerant more efficient and useful than existing magnetic refrigerants for commercialization of magnetic regenerators. The reversible first order phase transition is tunable from approximately 30 K to approximately 290 K (near room temperature) and above by compositional adjustments. The active magnetic regenerator and method can function for refrigerating, air conditioning, and liquefying low temperature cryogens with significantly improved efficiency and operating temperature range from approximately 10 K to 300 K and above. Also an active magnetic regenerator and method using Gd.sub.5 (Si.sub.x Ge.sub.1-x).sub.4, where x is equal to or greater than 0.5, as a magnetic heater/refrigerant that exhibits a reversible ferromagnetic/paramagnetic second order phase transition with large magneto-thermal properties, such as a large magnetocaloric effect that permits the commercialization of a magnetic heat pump and/or refrigerant. This second order phase transition is tunable from approximately 280 K (near room temperature) to approximately 350 K by composition adjustments. The active magnetic regenerator and method can function for low level heating for climate control for buildings, homes and automobile, and chemical processing.

Gschneidner, Jr., Karl A. (Ames, IA); Pecharsky, Vitalij K. (Ames, IA)

1998-04-28T23:59:59.000Z

242

Active magnetic refrigerants based on Gd-Si-Ge material and refrigeration apparatus and process  

DOE Patents (OSTI)

Active magnetic regenerator and method using Gd{sub 5} (Si{sub x}Ge{sub 1{minus}x}){sub 4}, where x is equal to or less than 0.5, as a magnetic refrigerant that exhibits a reversible ferromagnetic/antiferromagnetic or ferromagnetic-II/ferromagnetic-I first order phase transition and extraordinary magneto-thermal properties, such as a giant magnetocaloric effect, that renders the refrigerant more efficient and useful than existing magnetic refrigerants for commercialization of magnetic regenerators. The reversible first order phase transition is tunable from approximately 30 K to approximately 290 K (near room temperature) and above by compositional adjustments. The active magnetic regenerator and method can function for refrigerating, air conditioning, and liquefying low temperature cryogens with significantly improved efficiency and operating temperature range from approximately 10 K to 300 K and above. Also an active magnetic regenerator and method using Gd{sub 5} (Si{sub x} Ge{sub 1{minus}x}){sub 4}, where x is equal to or greater than 0.5, as a magnetic heater/refrigerant that exhibits a reversible ferromagnetic/paramagnetic second order phase transition with large magneto-thermal properties, such as a large magnetocaloric effect that permits the commercialization of a magnetic heat pump and/or refrigerant. This second order phase transition is tunable from approximately 280 K (near room temperature) to approximately 350 K by composition adjustments. The active magnetic regenerator and method can function for low level heating for climate control for buildings, homes and automobile, and chemical processing. 27 figs.

Gschneidner, K.A. Jr.; Pecharsky, V.K.

1998-04-28T23:59:59.000Z

243

Energy conservation for household refrigerators and water heaters  

Science Conference Proceedings (OSTI)

An energy conservation arrangement for household refrigerators and water heaters, in which the source of cold water to the hot water heater is divided and part is caused to flow through and be warmed in the condenser of the refrigerator. The warmed water is then further heated in the oil cooling loop of the refrigerator compressor, and proceeds then to the top of the hot water tank.

Speicher, T. L.

1984-12-11T23:59:59.000Z

244

List of Commercial Refrigeration Equipment Incentives | Open Energy  

Open Energy Info (EERE)

Refrigeration Equipment Incentives Refrigeration Equipment Incentives Jump to: navigation, search The following contains the list of 103 Commercial Refrigeration Equipment Incentives. CSV (rows 1 - 103) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Appalachian Power - Commercial and Industrial Rebate Programs (West Virginia) Utility Rebate Program West Virginia Commercial Industrial Central Air conditioners Chillers Custom/Others pending approval Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Programmable Thermostats Commercial Refrigeration Equipment Ground Source Heat Pumps Yes AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility

245

Geothermal: Sponsored by OSTI -- Chapter 13. Absorption Refrigeration  

Office of Scientific and Technical Information (OSTI)

GEOTHERMAL TECHNOLOGIES LEGACY COLLECTION - Sponsored by OSTI -- Chapter 13. Absorption Refrigeration Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us |...

246

Economizer refrigeration cycle space heating and cooling system and process  

DOE Patents (OSTI)

This invention relates to heating and cooling systems and more particularly to an improved system utilizing a Stirling Cycle engine heat pump in a refrigeration cycle. 18 figs.

Jardine, D.M.

1983-03-22T23:59:59.000Z

247

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

... may result from planned HVAC outages at night or ... recording data after the refrigerator was powered. ... the length of the power outage and the ...

2012-08-02T23:59:59.000Z

248

Electric, Gas, Water, Heating, Refrigeration, and Street Railways...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and Street Railways Facilities and Service (South Dakota) Electric, Gas, Water, Heating, Refrigeration, and Street Railways Facilities and Service (South Dakota) < Back...

249

The Ghana Refrigerator Efficiency Initiative - An Overview of...  

NLE Websites -- All DOE Office Websites (Extended Search)

refrigeration services the most expensive of energy services in residential Ghanaian households, posing serious financial burden on households. --The problem that this project...

250

Purchase of newer refrigerators slows during economic downturn ...  

U.S. Energy Information Administration (EIA)

Sales data from the Association of Home Appliance ... Decreasing sales of new refrigerators means slower adoption of new energy-efficient technology and less ...

251

Energy Efficiency Standards for Refrigerators in Brazil: A Methodology...  

Open Energy Info (EERE)

It uses a bottom-up approach to estimate residential end-use consumption and evaluate the energy saving potential for refrigerators. References Retrieved from "http:...

252

Federal Energy Management Program: New and Underutilized Refrigeration...  

NLE Websites -- All DOE Office Websites (Extended Search)

Power Management, and Vending Machine Technologies to someone by E-mail Share Federal Energy Management Program: New and Underutilized Refrigeration, Computer Power Management,...

253

Sustainable design of hydrocarbon refrigerants applied to the hermetic compressor.  

E-Print Network (OSTI)

??International environmental concern led to the control and phase out of traditional chlorofluorocarbon refrigerants (CFCs) under the terms of the Montreal protocol. CFCs used in… (more)

Garland, Nigel P.

2004-01-01T23:59:59.000Z

254

Magnetocaloric Refrigeration Concepts: Current State of the Art  

Science Conference Proceedings (OSTI)

Abstract Scope, Refrigeration devices based on the magnetocaloric effect have been ... Some of the major design choices are then evaluated and, based on ...

255

Refrigerator Efficiency in Ghana: Tailoring an Appliance Market...  

NLE Websites -- All DOE Office Websites (Extended Search)

Refrigerator Efficiency in Ghana: Tailoring an Appliance Market Transformation Program Design for Africa Publication Type Report LBNL Report Number LBNL-61251 Year of...

256

Enhancement of the Refrigerant Capacity in Partially Crystallized Gd ...  

Science Conference Proceedings (OSTI)

Consequently, the magnetic refrigerant capacity of the partially crystallized alloys is ... Alloy Design and Powder Processing of Mn-Al Based Materials for Rare ...

257

Economizer refrigeration cycle space heating and cooling system and process  

DOE Patents (OSTI)

This invention relates to heating and cooling systems and more particularly to an improved system utilizing a Stirling Cycle engine heat pump in a refrigeration cycle.

Jardine, Douglas M. (Colorado Springs, CO)

1983-01-01T23:59:59.000Z

258

DOE Opens Three Investigations into Alleged Refrigerator Efficiency...  

NLE Websites -- All DOE Office Websites (Extended Search)

The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that...

259

Boiler Stack Economizer Tube Failure  

Science Conference Proceedings (OSTI)

Presentation Title, Boiler Stack Economizer Tube Failure ... performed to investigate the failure of a type 304 stainless steel tube from a boiler stack economizer.

260

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

262

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network (OSTI)

icemakers and non-vapor compression refrigerators and2.5,+4.5) million non-vapor compression refrigerators inthe existence of non-vapor compression freezers. Moreover,

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

263

Refrigeration system with a compressor-pump unit and a liquid ...  

The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigera ...

264

Verification of a level-3 diesel emissions control strategy for transport refrigeration units.  

E-Print Network (OSTI)

??Transport Refrigeration Units (TRUs) are refrigeration systems used to control the environment of temperature sensitive products while they are being transported from one place to… (more)

Shewalla, Umesh.

2010-01-01T23:59:59.000Z

265

Design and Analysis of a Nested Halbach Permanent Magnet Magnetic Refrigerator.  

E-Print Network (OSTI)

??A technology with the potential to create efficient and compact refrigeration devices is an active magnetic regenerative refrigerator (AMRR). AMRRs exploit the magnetocaloric effect displayed… (more)

Tura, Armando

2013-01-01T23:59:59.000Z

266

YouTube  

Energy.gov (U.S. Department of Energy (DOE))

Note: Since the YouTube platform is always evolving, so are our best practices for using it. We welcome feedback and suggestions to keep processes current and up-to-date. For more information, read...

267

Magnetic refrigeration apparatus with heat pipes  

DOE Patents (OSTI)

A magnetic refrigerator operating in the 4 to 20 K range utilizes heat pipes to transfer heat to and from the magnetic material at the appropriate points during the material's movement. In one embodiment circular disks of magnetic material can be interleaved with the ends of the heat pipes. In another embodiment a mass of magnetic material reciprocatingly moves between the end of the heat pipe or pipes that transmits heat from the object of cooling to the magnetic material and the end of the heat pipe or pipes that transmits heat from the magnetic material to a heat sink.

Barclay, J.A.; Prenger, F.C. Jr.

1985-10-25T23:59:59.000Z

268

Magnetic refrigeration apparatus with heat pipes  

DOE Patents (OSTI)

A magnetic refrigerator operating in the 4 to 20 K range utilizes heat pipes to transfer heat to and from the magnetic material at the appropriate points during the material's movement. In one embodiment circular disks of magnetic material can be interleaved with the ends of the heat pipes. In another embodiment a mass of magnetic material reciprocatingly moves between the end of the heat pipe of pipes that transmits heat from the object of cooling to the magnetic material and the end of the heat pipe or pipes that transmits heat from the magnetic material to a heat sink.

Barclay, John A. (Los Alamos, NM); Prenger, Jr., F. Coyne (Madison, WI)

1987-01-01T23:59:59.000Z

269

Profilometer for tubes  

DOE Patents (OSTI)

An apparatus for inspecting interior surfaces of tubes or pipes. A spring-loaded sensor pin, slidably mounted in a rotatable housing is displaced in the housing as the housing is rotated. A centering means maintains spacing of the housing with respect to the tube wall. Displacement of the sensor pin in the housing are converted to measurable electrical signals by a linearly variable differential transformer.

Livingston, R.A.

1986-08-22T23:59:59.000Z

270

Solar absorption refrigeration system using new working fluid pairs  

Science Conference Proceedings (OSTI)

Absorption refrigeration systems powered by solar energy increasingly attract research interests in the last years. In this study, thermodynamic analyses for different working fluid pairs are performed. A computer simulation model has been developed ... Keywords: NH3-LiNO3, absorption, crystallization, generator, performance, refrigeration, solar energy

Jasim M. Abdulateef; Kamaruzzaman Sopian; M. A. Alghoul; Mohd Yusof Sulaiman; Azami Zaharim; Ibrahim Ahmad

2008-02-01T23:59:59.000Z

271

Performance monitoring strategies for effective running of commercial refrigeration systems  

Science Conference Proceedings (OSTI)

Refrigeration systems often represent the largest electricity consumers in the supermarkets. Therefore there is a clear need for running these systems effectively. Performance monitoring uses different techniques to determine the actual system state. ... Keywords: COP, FDD, energy monitoring, performance measure, refrigeration

Martin Hrn?ár; Petr Stluka

2010-05-01T23:59:59.000Z

272

Energy efficiency strategies in refrigeration systems of large supermarkets  

Science Conference Proceedings (OSTI)

Energy efficiency and its relationship with sustainable development are one of the most important objectives in modern engineering systems. In Industrial Installations that use refrigeration systems that are associated with the food industry, this optimization ... Keywords: energy efficiency, optimizing parameters, refrigeration systems, supermarkets

J. M. Garcia; L. M. R. Coelho

2010-07-01T23:59:59.000Z

273

Description and validation of a computer based refrigeration system simulator  

Science Conference Proceedings (OSTI)

This paper describes and evaluates the validation of a novel software package which simulates the transient and steady-state operation of whole refrigeration systems of the type used for the storage and processing of food. This software allows practitioners ... Keywords: Computer simulation, Food processing, Modelling, Refrigeration

I. W. Eames; T. Brown; J. A. Evans; G. G. Maidment

2012-07-01T23:59:59.000Z

274

Lanthanide Al-Ni base Ericsson cycle magnetic refrigerants  

DOE Patents (OSTI)

A magnetic refrigerant for a magnetic refrigerator using the Ericsson thermodynamic cycle comprises DyAlNi and (Gd{sub 0.54}Er{sub 0.46})AlNi alloys having a relatively constant {Delta}Tmc over a wide temperature range. 16 figs.

Gschneidner, K.A. Jr.; Takeya, Hiroyuki

1995-10-31T23:59:59.000Z

275

Embedded Smart Controller for an Industrial Reefer Refrigeration1  

E-Print Network (OSTI)

refrigeration control. The goal of this project is twofold: to design an efficient and economically feasibleEmbedded Smart Controller for an Industrial Reefer Refrigeration1 Leon Reznik and Shane Spiteri intelligent industrial controller on one hand and to test and further develop a smart device design approach

Reznik, Leon

276

REFRIGERATION OF FISH PART 5 DISTRIBUTION AND MARKETING  

E-Print Network (OSTI)

REFRIGERATION OF FISH· PART 5 DISTRIBUTION AND MARKETING OF FROZEN FISHERY PRODUCTS UNITED STATES in a series of five on "Refrigeration of Fish." Titles of the other four leaflets are: Part 1 (Fishery Leaflet 427) -- Cold-Storage Design and Refrigera- tion Equipnent Part 2 (Fishery Leaflet 428) -- Handling

277

New concepts for refrigerant leak detection and mixture measurement  

Science Conference Proceedings (OSTI)

Since the discovery that chlorofluorocarbons (CFCs) destroy the ozone layer, the need to reduce the release of these refrigerants into the environment has become critical. A total ban of ozone-depleting CFCs is expected within a few years, and hydrofluorocarbons (HFCs) and fluorocarbons (FCs) and their mixtures are expected to be used during a transition period. Several HFC and FC refrigerants are currently being considered as CFC substitutes. The electronic refrigerant leak detectors currently being considered as CFC substitutes. The electronic refrigerant leak detectors currently on the market were developed to detect CFCs and are not as sensitive to HFCs. Although incremental improvement can be made to these devices to detect HFCs, they often lead to increased false signals. Also, there is no simple device available to measure the composition of a refrigerant mixture. The authors present two new concepts to aid in the development of two portable instruments that can be used for HFC leak detection and for quantitative measurement of refrigerant mixture compositions. The development of simple, easy-to-use portable leak detectors and refrigerant mixture meters is essential to the wide use of alternative refrigerants in industry.

Chen, F.C.; Allman, S.L.; Chen, C.H.

1993-12-31T23:59:59.000Z

278

Lanthanide Al-Ni base Ericsson cycle magnetic refrigerants  

DOE Patents (OSTI)

A magnetic refrigerant for a magnetic refrigerator using the Ericsson thermodynamic cycle comprises DyAlNi and (Gd.sub.0.54 Er.sub.0.46)AlNi alloys having a relatively constant .DELTA.Tmc over a wide temperature range.

Gschneidner, Jr., Karl A. (Ames, IA); Takeya, Hiroyuki (Ibaraki, JP)

1995-10-31T23:59:59.000Z

279

Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Duracold Refrigeration Manufacturing: Proposed Penalty Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) February 21, 2013 DOE alleged in a Notice of Proposed Civil Penalty that Duracold Refrigeration Manufacturing Company, LLC failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342)

280

DOE Closes Investigation of Whirlpool's Maytag Refrigerator | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Closes Investigation of Whirlpool's Maytag Refrigerator Closes Investigation of Whirlpool's Maytag Refrigerator DOE Closes Investigation of Whirlpool's Maytag Refrigerator July 8, 2010 - 3:12pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Whirlpool's Maytag refrigerator-freezer model "MSD2578VE." The Department opened this investigation and requested testing data from Whirlpool based on a complaint (April 12, 2010, "DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations"). After reviewing the data and testing this model, the Department has found the model to be compliant with the applicable efficiency standards and has closed the investigation. The Department takes credible allegations seriously and will continue to initiate investigations on products that are

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

DOE Proposes Higher Efficiency Standards for Refrigerators | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Proposes Higher Efficiency Standards for Refrigerators DOE Proposes Higher Efficiency Standards for Refrigerators DOE Proposes Higher Efficiency Standards for Refrigerators September 28, 2010 - 12:00am Addthis WASHINGTON, DC - U.S. Energy Secretary Steven Chu today announced the release of a new proposed energy efficiency standard for residential refrigerators, refrigerator-freezers, and freezers. The standard, as proposed, could save consumers as much as $18.6 billion over thirty years. The Obama Administration has made efficiency standards a major priority as a way to save energy and money for American families and businesses. Since January 2009, the Department of Energy has finalized new efficiency standards for more than twenty household and commercial products, which will cumulatively save consumers between $250 billion and

282

North Star Refrigerator: Proposed Penalty (2013-CE-5355) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) March 26, 2013 DOE alleged in a Notice of Proposed Civil Penalty that North Star Refrigerator Co., Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. North Star Refrigerator: Proposed Penalty (2013-CE-5355) More Documents & Publications

283

North Star Refrigerator: Proposed Penalty (2013-CE-5355) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) March 26, 2013 DOE alleged in a Notice of Proposed Civil Penalty that North Star Refrigerator Co., Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. North Star Refrigerator: Proposed Penalty (2013-CE-5355) More Documents & Publications

284

DOE Closes Investigation of Whirlpool's Maytag Refrigerator | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

of Whirlpool's Maytag Refrigerator of Whirlpool's Maytag Refrigerator DOE Closes Investigation of Whirlpool's Maytag Refrigerator July 8, 2010 - 3:12pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Whirlpool's Maytag refrigerator-freezer model "MSD2578VE." The Department opened this investigation and requested testing data from Whirlpool based on a complaint (April 12, 2010, "DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations"). After reviewing the data and testing this model, the Department has found the model to be compliant with the applicable efficiency standards and has closed the investigation. The Department takes credible allegations seriously and will continue to initiate investigations on products that are

285

The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration  

Open Energy Info (EERE)

The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration and Air Conditioning Jump to: navigation, search Tool Summary LAUNCH TOOL Name: The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration and Air Conditioning Agency/Company /Organization: World Resources Institute, World Business Council for Sustainable Development Sector: Energy, Climate Focus Area: Greenhouse Gas Phase: Determine Baseline, Evaluate Effectiveness and Revise as Needed Resource Type: Software/modeling tools User Interface: Spreadsheet Website: www.ghgprotocol.org/calculation-tools/all-tools Cost: Free References: Refrigerant Guide[1] The Greenhouse Gas Protocol tool for refrigeration is a free Excel spreadsheet calculator designed to calculate GHG emissions specifically

286

Using Acid Number as a Leading Indicator of Refrigeration and Air Conditioning System Performance  

SciTech Connect

This report summarizes a literature review to assess the acidity characteristics of the older mineral oil and newer polyolester (POE) refrigeration systems as well as to evaluate acid measuring techniques used in other non-aqueous systems which may be applicable for refrigeration systems. Failure in the older chlorofluorocarbon/hydrochlorofluorocarbon (CFC/HCFC) / mineral oil systems was primarily due to thermal degradation of the refrigerant which resulted in the formation of hydrochloric and hydrofluoric acids. These are strong mineral acids, which can, over time, severely corrode the system metals and lead to the formation of copper plating on iron surfaces. The oil lubricants used in the older systems were relatively stable and were not prone to hydrolytic degradation due to the low solubility of water in oil. The refrigerants in the newer hydrofluorocarbon (HFC)/POE systems are much more thermally stable than the older CFC/HCFC refrigerants and mineral acid formation is negligible. However, acidity is produced in the new systems by hydrolytic decomposition of the POE lubricants with water to produce the parent organic acids and alcohols used to prepare the POE. The individual acids can therefore vary but they are generally C5 to C9 carboxylic acids. Organic acids are much weaker and far less corrosive to metals than the mineral acids from the older systems but they can, over long time periods, react with metals to form carboxylic metal salts. The salts tend to accumulate in narrow areas such as capillary tubes, particularly if residual hydrocarbon processing chemicals are present in the system, which can lead to plugging. The rate of acid production from POEs varies on a number of factors including chemical structure, moisture levels, temperature, acid concentration and metals. The hydrolysis rate of reaction can be reduced by using driers to reduce the free water concentration and by using scavenging chemicals which react with the system acids. Total acid number (TAN), which includes both mineral acids and organic acids, is therefore a useful indicator which can be used to monitor the condition of the system in order to perform remedial maintenance, when required, to prevent system failure. The critical TAN value is the acid level at which remedial action should be taken to prevent the onset of rapid acid formation which can result in system failure. The level of 0.05 mg KOH/g of oil was established for CFC/mineral oil systems based on analysis of 700 used lubricants from operating systems and failed units. There is no consensus within the refrigeration industry as to the critical TAN value for HFC/POE systems, however, the value will be higher than the CFC/mineral oil systems critical TAN value because of the much weaker organic acids produced from POE. A similar study of used POE lubricants should be performed to establish a critical TAN limit for POE systems. Titrimetric analysis per ASTM procedures is the most commonly used method to determine TAN values in lubricants in the refrigeration industry and other industries dealing with lubricating oils. For field measurements, acid test kits are often used since they provide rapid, semi-quantitative TAN results.

Dennis Cartlidge; Hans Schellhase

2003-07-31T23:59:59.000Z

287

APPLICATION OF NOVEL REGENERATOR MATERIAL WITHIN A COAXIAL TWO-STAGE PULSE TUBE REFRIGERATOR  

Science Conference Proceedings (OSTI)

We have developed a lead-based regenerator material which is suitable for working temperatures below 20 K. This material can be used as a substitute for the state of the art non-magnetic materials used today within very low-temperature regenerators. This high efficient regenerator matrix combines technological advantages with the possibility to vary the thermodynamic and flow characteristics over a wide range

T. Koettig; F. Richter; R. Nawrodt; A. Zimmer; C. Schwarz; D. Heinert; M. Thürk; P. Seidel

2008-01-01T23:59:59.000Z

288

The Impact of Charge on Performance of an Air-to-Air Heat Pump for R22 and Three Binary Blends of Refrigerants 32 and 134a  

E-Print Network (OSTI)

An experimental study was conducted in which the performance of three blends of R134a and R32 were compared to R22. The effect of refrigerant charge and the size of expansion device on the performance of these refrigerants in an air-to-air heat pump operating in the air-conditioning mode was quantified. All tests were conducted according to ASHRAE Standard 116 (1983). The mixtures consisted of 60%/40%, 70%/30% and 80%/20% ratios by mass of R134a and R32. Charge levels of 5, 5.45, 5.90 and 6.00 kilograms (11, 12, 13 and 14 pounds) were tested. At each charge level, outdoor room conditions of 27.8°C, 35.0°C and 40.6°C (82°F, 95°F and 105°F) were tested. For each combination of charge level and outdoor room temperature, orifice diameters of 1.64, 1.78, 1.96 and 2.07 millimeters (0.0645, 0.0700, 0.0770 and 0.0815 inches) were tested. Three variables were used to quantify refrigerant performance: total capacity, total electrical power consumption and coefficient of performance (COP). Several other variables such as mass flow rate, compressor suction pressures and differential pressures were also used to determine system characteristics. The performance of the three mixtures was not as good as the R22. The capacities were between 7 and 17% lower than R22. The energy efficiency ratios were IV within three percent in some cases but the corresponding capacities at these EERs were more than 12% lower than the R22 base case. The best results for a mixture was the 60/40 blend. The capacity was 7.3% lower than the base case and the EER was 8.5% lower.

Robinson, J. H.

1993-08-01T23:59:59.000Z

289

Effect of parasitic refrigeration on the efficiency of magnetic liquefiers  

SciTech Connect

Our studies have shown that magnetic refrigerators have the potential to liquefy cryogens very efficiently. High efficiency is especially important for liquid hydrogen and natural gas applications where the liquefaction costs are a significant fraction of the total liquid cost. One of the characteristics of magnetic refrigerators is the requirement for a high-field superconducting magnet. Providing a 4.2-K bath for this magnet will require a small amount of parasitic refrigeration at 4.2 K even though the rest of the liquefier may be at 110 K (liquid natural gas) or higher. For several different refrigeration power levels at 4.2 K, we have calculated the efficiency of the magnetic liquefier as a function of power, temperature and the 4.2-K refrigerator efficiency. The results show that if the ratio of the thermal load at 4.2 K to the main refrigerator power is 0.001 or less, the effect on the efficiency of the liquefier is negligible at all temperatures below room temperature provided the 4.2-K refrigerator efficiency is high.

Barclay, J.A.; Stewart, W.F.

1982-01-01T23:59:59.000Z

290

Energy Efficiency and Environmental Impact Analyses of Supermarket Refrigeration Systems  

SciTech Connect

This paper presents energy and life cycle climate performance (LCCP) analyses of a variety of supermarket refrigeration systems to identify designs that exhibit low environmental impact and high energy efficiency. EnergyPlus was used to model refrigeration systems in a variety of climate zones across the United States. The refrigeration systems that were modeled include the traditional multiplex DX system, cascade systems with secondary loops and the transcritical CO2 system. Furthermore, a variety of refrigerants were investigated, including R-32, R-134a, R-404A, R-1234yf, R-717, and R-744. LCCP analysis was used to determine the direct and indirect carbon dioxide emissions resulting from the operation of the various refrigeration systems over their lifetimes. Our analysis revealed that high-efficiency supermarket refrigeration systems may result in up to 44% less energy consumption and 78% reduced carbon dioxide emissions compared to the baseline multiplex DX system. This is an encouraging result for legislators, policy makers and supermarket owners to select low emission, high-efficiency commercial refrigeration system designs for future retrofit and new projects.

Fricke, Brian A [ORNL; Bansal, Pradeep [ORNL; Zha, Shitong [Hillphoenix

2013-01-01T23:59:59.000Z

291

A New Absorption Cycle: The Single-Effect Regenerative Absoprtion Refrigeration Cycle  

E-Print Network (OSTI)

REGENERATIVE ABSORPTION REFRIGERATION CYCLE ABSTRACT A new absorption cycle , using heat as the energy

Dao, K.

2011-01-01T23:59:59.000Z

292

Evolution of the Standard Helium Liquefier and Refrigerator Range designed by Air Liquide DTA, France  

E-Print Network (OSTI)

Evolution of the Standard Helium Liquefier and Refrigerator Range designed by Air Liquide DTA, France

Crispel, S; Caillaud, A; Delcayre, F; Grabie, V

2008-01-01T23:59:59.000Z

293

Research of Refrigerant Phase-Change Stirling-Cycle Heat Engines  

Science Conference Proceedings (OSTI)

This paper firstly introduces the principles of Refrigerant Phase-Change Stirling-Cycle solar power towers This heat engines use solar reservoire. When the refrigerant in an engine cylinder absorbs heat from high-temperature heat sources, refrigerant ... Keywords: refrigerant phase-change cycle, heat engines, finite-time thermodynamics

Dezhong Huang; Fuer Wu

2011-01-01T23:59:59.000Z

294

Shock Tube Design  

E-Print Network (OSTI)

Shock accelerated flows exhibit some of the most violent and complex mechanisms in nature by which two separate fluids can be mixed. The Richtmyer-Meshkov instability (RMI) is generated when a perturbed interface between two fluids is impulsively accelerated by a shock wave. In order to further study the phenomenon of the RMI, a new shock tube will be designed. This shock tube will have the capability to change the angle of inclination, allowing for a diverse possibility of fluid interfaces, and provide two driver sections to allow for dual shock capability. The tube was designed to accommodate a 2.5 MACH shockwave, and incorporated a factor of safety of 3 in the design. A modular approach to design was followed to allow further diversification of the shock tube by changing the configuration of the modules. A circular driver section was used to maximize volume and a square driven section was used to minimize affects from the boundary layer. A slide rail mechanism was devised for changing the diaphragms which allows a single person to change the diaphragm in a timely manner. The entire tube is supported on an I-beam to maintain the rigidity of the system while inclined. To accommodate a variable inclination, a hybrid winch support system was designed. A winch changes the angle of the tube and a telescoping support system maintains the position during experimentation. It was determined after running COSMOS finite element stress analysis, that with the 2.5 MPa internal pressure associated with a 2.5 MACH shock wave, a 19.05 mm sidewall thickness was needed to provide a factor of safety of 3.

Koppenberger, Peter K.

2010-05-01T23:59:59.000Z

295

New Regenerative Cycle for Vapor Compression Refrigeration  

Office of Scientific and Technical Information (OSTI)

SCIENTIFIC REPORT SCIENTIFIC REPORT Title Page Project Title: New Regenerative Cycle for Vapor Compression Refrigeration DOE Award Number: DE-FG36-04GO14327 Document Title: Final Scientific Report Period Covered by Report: September 30, 2004 to September 30, 2005 Name and Address of Recipient Organization: Magnetic Development, Inc., 68 Winterhill Road, Madison, CT 06443, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Contact Information: Mark J. Bergander, Ph.D., P.E., Principal Investigator, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Project Objective (as stated in the proposal): The main objective of this project is to confirm on a well-instrumented prototype the theoretically derived claims of higher efficiency and coefficient

296

Bipolar pulse field for magnetic refrigeration  

DOE Patents (OSTI)

A magnetic refrigeration apparatus includes first and second steady state magnets, each having a field of substantially equal strength and opposite polarity, first and second bodies made of magnetocaloric material disposed respectively in the influence of the fields of the first and second steady state magnets, and a pulsed magnet, concentric with the first and second steady state magnets, and having a field which cycles between the fields of the first and second steady state magnets, thereby cyclically magnetizing and demagnetizing and thus heating and cooling the first and second bodies. Heat exchange apparatus of suitable design can be used to expose a working fluid to the first and second bodies of magnetocaloric material. A controller is provided to synchronize the flow of working fluid with the changing states of magnetization of the first and second bodies. 2 figs.

Lubell, M.S.

1994-10-25T23:59:59.000Z

297

Safety audit of refrigerated liquefied gas facilities  

SciTech Connect

An Exxon Research and Engineering Co. comprehensive review of engineering practices and application of safety requirements at Exxon's world-wide refrigerated liquefied hydrocarbon gas storage and handling installations, which included a field audit of about 90 tanks at 30 locations, showed that catastrophic tank failure was not a credible event with properly operated and maintained tanks designed, constructed, and tested in accordance with API Standard 620, Design and Construction of Large Welded Low-Pressure Storage Tanks, although supplemental requirements were suggested to further enhance safety. The review also showed that any meaningful safety audit should be comprehensive and must include all facilities with careful attention to detail. The review embraces products of -1 to -167C and included LNG, ethylene, LPG, and LPG olefins. Recent and proposed LNG safety legislation; some field audit results; and recommendations as to design, construction, and operation of LNG and LPG storage facilities, marine terminals, and tankers, are also discussed.

Feely, F.J.; Sommer, E.C.; Marshall, B.T.; Palmer, A.J.

1980-01-01T23:59:59.000Z

298

Designing Environmentally Safe Refrigerants Using Mathematical Programming  

E-Print Network (OSTI)

Computer aided molecular design is a strategy in which a set of structural groups are systematically combined to form molecules with desired properties. In this paper, a mathematical programming based approach to computer aided molecular design is presented. Using a set of structural groups, the problem is formulated as a mixed integer nonlinear program in which discrete variables represent the number of each type of structural groups present in the candidate compound. The augmentedpenalty /outer-approximation algorithm is used to solve the MINLP to obtain compound(s) with an optimum value of an appropriate performance index such that molecular structural constraints, physical property constraints and process design limitations are met. With the current renewed interest in the environment, the suggested approach is applied to refrigerant design with an environmental constraint. The results indicate the viability of this approach. INTRODUCTION The chemical industry is constantly explo...

Amit P. Duvedi; Luke E. K. Achenie; Copyright Amit Duvedi; Luke Achenie

1996-01-01T23:59:59.000Z

299

Microcomputer Software for Refrigerant Property and Cycle Analysis Calculations  

E-Print Network (OSTI)

A microcomputer program entitled REFRIG has been developed to determine the thermodynamic properties of common refrigerants and to analyze vapor-compression refrigeration cycles. This paper describes the theoretical basis for property determination and for the cycle analysis. Validation of property calculations is discussed. A number of features are described which have been incorporated into the program to enhance its usefulness to the engineer in analyzing system performance. Two example cases are presented to illustrate the application of the program to problems in design and operation of refrigeration systems.

Bierschenk, J. L.; Strohl, S. T.; Schmidt, P. S.

1985-05-01T23:59:59.000Z

300

Development of Refrigerant Change Indicator and Dirty Air Filter Sensor  

Science Conference Proceedings (OSTI)

The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks and dirty air filters. Equipment users are usually not aware of a problem until most of the refrigerant has escaped or the air filter is clogged with dirt. While a dirty air filter can be detected with a technology based on the air pressure differential across the filter, such as a ''whistling'' indicator, it is not easy to incorporate this technology into existing HVAC diagnostic equipment. Oak Ridge National Laboratory is developing a low-cost, nonintrusive refrigerant charge indicator and dirty air filter detection sensor. The sensors, based on temperature measurements, will be inexpensive and easy to incorporate into existing heat pumps and air conditioners. The refrigerant charge indicator is based on the fact that when refrigerant starts to leak, the evaporator coil temperature starts to drop and the level of liquid subcooling drops. When the coil temperature or liquid subcooling drops below a preset reading, a signal, such as a yellow warning light, can be activated to warn the equipment user that the system is undercharged. A further drop of coil temperature or liquid subcooling below another preset reading would trigger a second warning signal, such as a red warning light, to warn the equipment user that the unit now detects a leak and immediate action should be taken. The warning light cannot be turned off until it is re-set by a refrigeration repairman. To detect clogged air filters, two additional temperature sensors can be applied, one each across the evaporator. When the air filter is accumulating buildup, the temperature differential across the evaporator will increase because of the reduced airflow. When the temperature differential reaches a pre-set reading, a signal will be sent to the equipment user that the air filter needs to be changed. A traditional refrigerant charge indicator requires intrusion into the system to measure the refrigerant high-side and low-side pressures. Once the pressures are known, based on the equipment's refrigerant charging chart? or in most cases, based on the technician's experience? the refrigerant charging status is determined. However, there is a catch: by the time a refrigeration technician is called, most of the refrigerant has already escaped into the atmosphere. The new technology provides a real-time warning so that when, say, 20% of the refrigerant has leaked, the equipment users will be warned, even though the equipment is still functioning properly at rated capacity. Temperature sensors are becoming very accurate and very low in cost, compared with pressure sensors. Using temperature sensors to detect refrigerant charge status is inherently nonintrusive, inexpensive, and accurate. With the addition of two temperature sensors for detecting dirty air filters, the capability of the diagnostic equipment is further enhanced with very little added cost. This report provides laboratory test data on the change of indoor coil refrigerant temperature and subcooling as a function of refrigerant charge for a 2-ton split heat pump system. The data can be used in designing the indicators for refrigerant loss and dirty air filter sensors.

Mei, V.

2003-06-24T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Property:Building/SPElectrtyUsePercRefrigeration | Open Energy Information  

Open Energy Info (EERE)

SPElectrtyUsePercRefrigeration SPElectrtyUsePercRefrigeration Jump to: navigation, search This is a property of type String. Refrigeration Pages using the property "Building/SPElectrtyUsePercRefrigeration" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 0.0 + Sweden Building 05K0002 + 0.0 + Sweden Building 05K0003 + 0.0 + Sweden Building 05K0004 + 0.0 + Sweden Building 05K0005 + 0.0 + Sweden Building 05K0006 + 4.24846345193 + Sweden Building 05K0007 + 0.0 + Sweden Building 05K0008 + 0.0 + Sweden Building 05K0009 + 0.0 + Sweden Building 05K0010 + 24.6944086225 + Sweden Building 05K0011 + 0.0 + Sweden Building 05K0012 + 0.0 + Sweden Building 05K0013 + 1.29913989581 + Sweden Building 05K0014 + 7.46645043826 + Sweden Building 05K0015 + 0.0 +

302

DOE Reaches Agreement with LG Electronics, USA, On Refrigerator Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reaches Agreement with LG Electronics, USA, On Refrigerator Reaches Agreement with LG Electronics, USA, On Refrigerator Energy Matter DOE Reaches Agreement with LG Electronics, USA, On Refrigerator Energy Matter November 14, 2008 - 4:47pm Addthis ENERGY STAR® Program Continues to Help American Consumers Make Energy Efficient Choices WASHINGTON - The U.S. Department of Energy (DOE) today announced an agreement with LG Electronics, USA, Inc. (LG), resolving concerns related to energy usage measurements reported on LG French Door refrigerators with through-the-door ice and water service. The ENERGY STAR® program helps American consumers make energy efficient choices, saving billions of dollars while protecting the environment by using identified energy efficient products and practices. "DOE believes that the actions LG plans to take will benefit consumers and

303

Computer program for determining the thermodynamic properties of Freon refrigerants  

DOE Green Energy (OSTI)

This program was written to be used as a subroutine. The program determines the thermodynamics of Freon refrigerants. The following refrigerants can be analyzed F-11, F-12, F-13, F-14, F-21, F-22, F-23, F-113, and F-114. The subroutine can evaluate a thermodynamic state for these refrigerants given any of the following pairs of state quantities: pressure and quality, pressure and entropy, pressure and enthalpy, temperature and quality, temperature and specific volume, and temperature and pressure. These six pairs of knowns allow the user to analyze any thermodynamic cycle utilizing a refrigerant as the working fluid. The Downing form of the Martin equation of state was used. This report contains a brief description, flow chart and listing of all subroutines required.

Riemer, D.H.; Jacobs, H.R.; Boehm, R.F.

1977-12-01T23:59:59.000Z

304

Computer program for determining the thermodynamic properties of freon refrigerants  

DOE Green Energy (OSTI)

This program was written to be used as a subroutine. The program determines the thermodynamics of Freon refrigerants. The following refrigerants can be analyzed F-11, F-12, F-13, F-14, F-21, F-22, F-23, F-113, and F-114. The subroutine can evaluate a thermodynamic state for these refrigerants given any of the following pairs of state quantities: pressure and quality, pressure and entropy, pressure and enthalpy, temperature and quality, temperature and specific volume and temperature and pressure. These six pairs of knowns allow the user to analyze any thermodynamic cycle utilizing a refrigerant as the working fluid. The Downing form of the Martin equation of state was used. A brief description, flow chart, and listing of all subroutines required are presented.

Riemer, D.H.; Jacobs, H.R.; Boehm, R.F.

1976-07-01T23:59:59.000Z

305

Improved Algorithm and Simulation of the Provision Refrigerating Unit  

Science Conference Proceedings (OSTI)

The dynamic model of reciprocating provision cooling plant is presented, and the algorithm of the model is amended, through the method of quoting an unknown variable, which is enthalpy of the refrigerant at the compressor outlet. Dynamic simulation of ...

HE Zhi-bin; ZHANG Jun-dong; SUN Yu-qing; ZENG Hong; GAN Hui-bing

2007-09-01T23:59:59.000Z

306

DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star  

NLE Websites -- All DOE Office Websites (Extended Search)

Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements March 16, 2010 - 4:28pm Addthis DOE-initiated testing has revealed that a Samsung refrigerator (model RF26VAB), which the company had claimed was Energy Star compliant, consumed more energy than permitted by the Energy Star program. Test results for the Samsung model at issue show that, when tested in accordance with DOE's test procedure, it consumed between 7 and 11.4 percent more energy than the Energy Star requirement. Samsung is no longer manufacturing this model, although it may still be available from some retail outlets. Based on this testing, DOE is referring Samsung Model RF26VAB to the U.S.

307

Covered Product Category: Residential Refrigerators | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Refrigerators Residential Refrigerators Covered Product Category: Residential Refrigerators October 7, 2013 - 11:19am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including residential refrigerators, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

308

Product Standards for Refrigerators (Japan) | Open Energy Information  

Open Energy Info (EERE)

Product Standards for Refrigerators (Japan) Product Standards for Refrigerators (Japan) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Product Standards for Refrigerators (Japan) Focus Area: Appliances & Equipment Topics: Policy Impacts Website: www.eccj.or.jp/top_runner/pdf/tr_re-freez_Jul.2006.pdf Equivalent URI: cleanenergysolutions.org/content/product-standards-refrigerators-japan Language: English Policies: "Deployment Programs,Regulations" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Industry Codes & Standards Regulations: Appliance & Equipment Standards and Required Labeling This Energy Conservation Center Japan (ECCJ) document was created as a guide in response to its newly established set of standards and labelling

309

Covered Product Category: Residential Refrigerators | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Refrigerators Refrigerators Covered Product Category: Residential Refrigerators October 7, 2013 - 11:19am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including residential refrigerators, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

310

Energy Department Announces More Stringent Criteria for ENERGY STAR® Refrigerators  

Energy.gov (U.S. Department of Energy (DOE))

WASHINGTON, DC - The U.S. Department of Energy (DOE) today announced increased energy efficient criteria for refrigerators carrying the ENERGY STAR® label.  In order to qualify, full-size...

311

Commercial Refrigerator Door: Proposed Penalty (2013-CE-5351)  

Energy.gov (U.S. Department of Energy (DOE))

DOE alleged in a Notice of Proposed Civil Penalty that Commercial Refrigerator Door Company, Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards.

312

Detailed CFD modelling of open refrigerated display cabinets  

Science Conference Proceedings (OSTI)

A comprehensive and detailed computational fluid dynamics (CFDs) modelling of air flow and heat transfer in an open refrigerated display cabinet (ORDC) is performed in this study. The physical-mathematical model considers the flow through the internal ...

Pedro Dinis Gaspar; L. C. Carrilho Gonçalves; R. A. Pitarma

2012-01-01T23:59:59.000Z

313

Energy Consumption of Refrigerators in Ghana - Outcomes of Household...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Consumption of Refrigerators in Ghana - Outcomes of Household Surveys Speaker(s): Essel Ben Hagan Date: July 12, 2007 - 12:00pm Location: 90-3122 Seminar HostPoint of...

314

Extreme solid state refrigeration using nanostructured Bi-Te alloys.  

SciTech Connect

Materials are desperately needed for cryogenic solid state refrigeration. We have investigated nanostructured Bi-Te alloys for their potential use in Ettingshausen refrigeration to liquid nitrogen temperatures. These alloys form alternating layers of Bi{sub 2} and Bi{sub 2}Te{sub 3} blocks in equilibrium. The composition Bi{sub 4}Te{sub 3} was identified as having the greatest potential for having a high Ettingshausen figure of merit. Both single crystal and polycrystalline forms of this material were synthesized. After evaluating the Ettingshausen figure of merit for a large, high quality polycrystal, we simulated the limits of practical refrigeration in this material from 200 to 77 K using a simple device model. The band structure was also computed and compared to experiments. We discuss the crystal growth, transport physics, and practical refrigeration potential of Bi-Te alloys.

Lima Sharma, Ana L. (San Jose State University, San Jose, CA); Spataru, Dan Catalin; Medlin, Douglas L.; Sharma, Peter Anand; Morales, Alfredo Martin

2009-09-01T23:59:59.000Z

315

Advanced refrigeration system for the Brookhaven superconducting cable project  

SciTech Connect

A description is given of a basic supercritical refrigerator. The present status of the cable enclosure and the types of cooling schemes being considered are presented with some examples of laboratory results and computer analysis. (MOW)

Jensen, J.E.

1975-01-01T23:59:59.000Z

316

Application of Cryocoolers to a Vintage Dilution Refrigerator  

SciTech Connect

A dilution refrigerator is required for 50mK detector operation of CDMS (Cryogenic Dark Matter Search). Besides shielding the dilution refrigerator itself, the liquid nitrogen shield and liquid helium bath in the refrigerator cool the detector cryostat heat shields and cool electronics, resulting in significant external heat loads at 80K and at 4K. An Oxford Instruments Kelvinox 400 has served this role for ten years but required daily transfers of liquid nitrogen and liquid helium. Complicating the cryogen supply is the location 800 meters below ground in an RF shielded, class 10000 clean room at Soudan, MN. Nitrogen and helium re-liquefiers using cryocoolers were installed outside the clean room and continuously condense room temperature gas and return the liquids to the dilution refrigerator through a transfer line. This paper will describe the design, installation, controls and performance of liquefaction systems.

Schmitt, Richard; Smith, Gary; Ruschman, Mark; /Fermilab; Beaty, Jim; /Minnesota U.

2011-06-06T23:59:59.000Z

317

Removing Odors from Refrigerators and Freezers after Food has Spoiled  

E-Print Network (OSTI)

If food has spoiled in a refrigerator or freezer because of a power outage or some other reason, undesirable odors can result. This publication explains how to eliminate odors from these appliances.

FCS Project Team - FDRM UNIT

2005-09-30T23:59:59.000Z

318

Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Thermodynamic Evaluation of Thermodynamic Evaluation of Low-GWP Refrigerants Mark O. McLinden National Institute of Standards and Technology markm@boulder.nist.gov; 303-497-3580 April 3, 2013 Optimization Fluid Modeling Cycle Modeling Final Candidates Optimum Thermo Parameters 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: HFC refrigerants face restrictions: U.S./Canada/Mexico proposal to Montreal Protocol (85 % cut) EU regulations likely on all application areas (79 % cut)

319

Improving the energy efficiency of refrigerators in India  

Science Conference Proceedings (OSTI)

Five state-of-the-art, production refrigerators from different manufacturers in India were subjected to a variety of appliance rating and performance evaluation test procedures in an engineering laboratory. Cabinet heat loss, compressor calorimeter, high-ambient pull-down, and closed-door energy consumption tests were performed on each unit to assess the current status of commercially available Indian refrigerators and refrigerator component efficiencies. Daily energy consumption tests were performed at nominal line voltages and at 85% and 115% of nominal voltage to assess the effect of grid voltage variations. These test results were also used to indicate opportunities for effective improvements in energy efficiency. A widely distributed ``generic`` computer model capable of simulating single-door refrigerators with a small interior freezer section was used to estimate cabinet heat loss rates and closed door energy consumption values from basic cabinet and refrigeration circuit inputs. This work helped verify the model`s accuracy and potential value as a tool for evaluating the energy impact of proposed design options. Significant differences ranging from 30 to 90% were seen in the measured performance criterion for these ``comparable`` refrigerators suggesting opportunities for improvements in individual product designs. Modeled cabinet heat loadings differed from experimentally extrapolated values in a range from 2--29%, and daily energy consumption values estimated by the model differed from laboratory data by as little as 3% or as much as 25%, which indicates that refinement of the model may be needed for this single-door refrigerator type. Additional comparisons of experimentally measured performance criteria such as % compressor run times and compressor cycling rates to modeled results are given. The computer model is used to evaluate the energy saving impact of several modest changes to the basic Indian refrigerator design.

Sand, J.R.; Vineyard, E.A. [Oak Ridge National Lab., TN (United States); Bohman, R.H. [Consulting Engineer, Cedar Rapids, IA (United States)

1995-04-01T23:59:59.000Z

320

Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants  

NLE Websites -- All DOE Office Websites (Extended Search)

Thermodynamic Evaluation of Thermodynamic Evaluation of Low-GWP Refrigerants Mark O. McLinden National Institute of Standards and Technology markm@boulder.nist.gov; 303-497-3580 April 3, 2013 Optimization Fluid Modeling Cycle Modeling Final Candidates Optimum Thermo Parameters 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: HFC refrigerants face restrictions: U.S./Canada/Mexico proposal to Montreal Protocol (85 % cut) EU regulations likely on all application areas (79 % cut)

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

ARI delegation to Japan on Alternative Refrigerants. [Foreign Trip Report  

SciTech Connect

Researchers from ARI member companies spoke at the International Conference on Alternative Refrigerants in Tokyo and visited several Japanese organizations for the purpose of exchanging information on alternative refrigerants. The specific purpose of the meetings was to review the methods being utilized to screen alternatives to CFCs and HCFCs: materials compatibility screening methods, lubricant testing techniques, as well as flammability studies. A list of papers presented at the conference is included.

Not Available

1993-02-01T23:59:59.000Z

322

Hybrid refrigeration/sorption solar-cooling systems  

DOE Green Energy (OSTI)

The hybrid refrigeration/sorption concept is a technically feasible approach to solar cooling which has not yet been systematically evaluated. Various system configurations are possible, each with advantages and disadvantages relative to the others, and with respect to solar cooling systems based on the individual absorption, Rankine, and desiccant technologies. Conventional cooling and dehumidification, sorption dehumidification, and the effects on the refrigeration unit of adding a dehumidifier are discussed.

Curran, H.M.

1981-08-01T23:59:59.000Z

323

Transport Refrigeration Equipment: Analysis of Emissions and Economics of Electrification  

Science Conference Proceedings (OSTI)

Most refrigerated trucks, trailers, and ocean containers used to transport, deliver, and store fresh and frozen foods utilize an auxiliary diesel engine (10 to 34 hp) to operate on-board refrigeration systems. These engines are vital for product temperature control while the vehicle is on the road, but also idle while the truck is parked at a facility, pre-cooling, loading, unloading, or waiting to be dispatched. As a result, large distribution centers can experience high concentrations of pollutants and...

2004-06-30T23:59:59.000Z

324

Compatibility of refrigerants and lubricants with engineering plastics  

Science Conference Proceedings (OSTI)

All seven oil immersion studies are complete at both temperatures. Nine out of ten refrigerant ambient immersion studies are complete including 60C (140F) for R-123. All 22 plastic test materials have been molded into test bars. All test bars have been quality controlled for physical consistency and integrity. All 22 test chambers are functional. Creep loads have been increased to 25% of ultimate tensile. Refrigerant has solubilities of Emery 2927 with R-22 and 134a are complete.

Cavestri, R.C.

1992-07-01T23:59:59.000Z

325

Tubing on the Ichetucknee Countries  

E-Print Network (OSTI)

, crystal clear water of the Ichetucknee River while you relax in an inner tube. Enjoy the Florida sunshine

Príncipe, José Carlos

326

Heat exchanger bypass system for an absorption refrigeration system  

DOE Patents (OSTI)

A heat exchanger bypass system for an absorption refrigeration system is disclosed. The bypass system operates to pass strong solution from the generator around the heat exchanger to the absorber of the absorption refrigeration system when strong solution builds up in the generator above a selected level indicative of solidification of strong solution in the heat exchanger or other such blockage. The bypass system includes a bypass line with a gooseneck located in the generator for controlling flow of strong solution into the bypass line and for preventing refrigerant vapor in the generator from entering the bypass line during normal operation of the refrigeration system. Also, the bypass line includes a trap section filled with liquid for providing a barrier to maintain the normal pressure difference between the generator and the absorber even when the gooseneck of the bypass line is exposed to refrigerant vapor in the generator. Strong solution, which may accumulate in the trap section of the bypass line, is diluted, to prevent solidification, by supplying weak solution to the trap section from a purge system for the absorption refrigeration system.

Reimann, Robert C. (Lafayette, NY)

1984-01-01T23:59:59.000Z

327

Polarized target with dilution refrigerator: why and how  

DOE Green Energy (OSTI)

Polarized targets using dilution refrigerators have several advantages over targets of He/sup 3/ cryostats for some polarization experiments. One of the advantages is in the long nuclear spin lattice relaxation time in quite low temperatures. It permits holding the target polarization in a magnetic field different from the polarizing field. Another merit is in the fact that one can obtain higher polarization in a dilution refrigerator than in a He/sup 3/ cryostat, especially in the case of deuterons. These facts suggest various applications of the target with a dilution refrigerator, such as a spin-frozen target for spin-rotation parameter measurements, a target for spin effects in inelastic scattering, high polarized deuteron target, and so on. Furthermore, one can hopefully make a highly polarized HD target with further improvements of the dilution refrigerator. The possibility of the solid hydrogen polarization is also discussed. Finally, the principle of the dilution refrigerator and the special features of the refrigerator for the polarized target are briefly described. 7 figures.

Masaike, A.

1977-09-01T23:59:59.000Z

328

New Regenerative Cycle for Vapor Compression Refrigeration  

SciTech Connect

The main objective of this project is to confirm on a well-instrumented prototype the theoretically derived claims of higher efficiency and coefficient of performance for geothermal heat pumps based on a new regenerative thermodynamic cycle as comparing to existing technology. In order to demonstrate the improved performance of the prototype, it will be compared to published parameters of commercially available geothermal heat pumps manufactured by US and foreign companies. Other objectives are to optimize the design parameters and to determine the economic viability of the new technology. Background (as stated in the proposal): The proposed technology closely relates to EERE mission by improving energy efficiency, bringing clean, reliable and affordable heating and cooling to the residential and commercial buildings and reducing greenhouse gases emission. It can provide the same amount of heating and cooling with considerably less use of electrical energy and consequently has a potential of reducing our nations dependence on foreign oil. The theoretical basis for the proposed thermodynamic cycle was previously developed and was originally called a dynamic equilibrium method. This theory considers the dynamic equations of state of the working fluid and proposes the methods for modification of T-S trajectories of adiabatic transformation by changing dynamic properties of gas, such as flow rate, speed and acceleration. The substance of this proposal is a thermodynamic cycle characterized by the regenerative use of the potential energy of two-phase flow expansion, which in traditional systems is lost in expansion valves. The essential new features of the process are: (1) The application of two-step throttling of the working fluid and two-step compression of its vapor phase. (2) Use of a compressor as the initial step compression and a jet device as a second step, where throttling and compression are combined. (3) Controlled ratio of a working fluid at the first and second step of compression. In the proposed system, the compressor compresses the vapor only to 50-60% of the final pressure, while the additional compression is provided by a jet device using internal potential energy of the working fluid flow. Therefore, the amount of mechanical energy required by a compressor is significantly reduced, resulting in the increase of efficiency (either COP or EER). The novelty of the cycle is in the equipment and in the way the multi-staging is accomplished. The anticipated result will be a new refrigeration system that requires less energy to accomplish a cooling task. The application of this technology will be for more efficient designs of: (1) Industrial chillers, (2) Refrigeration plants, (3) Heat pumps, (4) Gas Liquefaction plants, (5) Cryogenic systems.

Mark J. Bergander

2005-08-29T23:59:59.000Z

329

Photomultiplier Tube Home  

NLE Websites -- All DOE Office Websites (Extended Search)

Project Homepage Project Homepage Classroom Projects Homepage - Teacher Homepage - Student Homepage Abstract: Photons are created in scintillator devices in most modern particle detectors. These photons yield information about particle collisions that must be measured and decoded. This Website follows the track of a photon as it enters a photomultiplier tube (pmt), an amplifying device that increases the effect of a single photon to levels that are measurable. This signal amplification is crucial; without it, no information exists for decoding. The site presents information regarding the innards of a pmt and allows students to investigate predictive mathematical models describing the signal increase under different, adjustable parameters. Introduction to Research: Photomultipler tubes are omnipresent in particle physics. Understanding the

330

Induction plasma tube  

DOE Patents (OSTI)

An induction plasma tube having a segmented, fluid-cooled internal radiation shield is disclosed. The individual segments are thick in cross-section such that the shield occupies a substantial fraction of the internal volume of the plasma enclosure, resulting in improved performance and higher sustainable plasma temperatures. The individual segments of the shield are preferably cooled by means of a counterflow fluid cooling system wherein each segment includes a central bore and a fluid supply tube extending into the bore. The counterflow cooling system results in improved cooling of the individual segments and also permits use of relatively larger shield segments which permit improved electromagnetic coupling between the induction coil and a plasma located inside the shield. Four embodiments of the invention, each having particular advantages, are disclosed.

Hull, D.E.

1982-07-02T23:59:59.000Z

331

Induction plasma tube  

DOE Patents (OSTI)

An induction plasma tube having a segmented, fluid-cooled internal radiation shield is disclosed. The individual segments are thick in cross-section such that the shield occupies a substantial fraction of the internal volume of the plasma enclosure, resulting in improved performance and higher sustainable plasma temperatures. The individual segments of the shield are preferably cooled by means of a counterflow fluid cooling system wherein each segment includes a central bore and a fluid supply tube extending into the bore. The counterflow cooling system results in improved cooling of the individual segments and also permits use of relatively larger shield segments which permit improved electromagnetic coupling between the induction coil and a plasma located inside the shield. Four embodiments of the invention, each having particular advantages, are disclosed.

Hull, Donald E. (Los Alamos, NM)

1984-01-01T23:59:59.000Z

332

Joined concentric tubes  

SciTech Connect

Tubular objects having two or more concentric layers that have different properties are joined to one another during their manufacture primarily by compressive and friction forces generated by shrinkage during sintering and possibly mechanical interlocking. It is not necessary for the concentric tubes to display adhesive-, chemical- or sinter-bonding to each other in order to achieve a strong bond. This facilitates joining of dissimilar materials, such as ceramics and metals.

DeJonghe, Lutgard; Jacobson, Craig; Tucker, Michael; Visco, Steven

2013-01-01T23:59:59.000Z

333

Heat pump employing optimal refrigerant compressor for low pressure ratio applications  

DOE Patents (OSTI)

What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler for circulating the fluid in heat exchange relationship with a refrigerant fluid; two refrigerant heat exchangers; one for effecting the heat exchange with the fluid and a second refrigerant-heat exchange fluid heat exchanger for effecting a low pressure ratio of compression of the refrigerant; a rotary compressor for compressing the refrigerant with low power consumption at the low pressure ratio; at least one throttling valve connecting at the inlet side of heat exchanger in which liquid refrigerant is vaporized; a refrigerant circuit serially connecting the above elements; refrigerant in the circuit; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant.

Ecker, Amir L. (Dallas, TX)

1982-01-01T23:59:59.000Z

334

An Advanced Solar-Powered Rotary Solid Adsorption Refrigerator with High Performance  

E-Print Network (OSTI)

In this paper, according to practical consideration, a new solar powered rotary solid adsorption refrigerator system adopting activated carbon fibre + ethanol as its adsorption pair has been designed with higher performance. Moreover, the principle of the refrigeration cycle, different components of the machine, selection of working pairs and feasible theory analysis of the refrigeration system all have been presented in detail. In addition, it shows that the new refrigerator has many great advantages including a simple structure, fast refrigeration, higher thermodynamic coefficient, friendly to the atmospheric environment, etc. This paper explains that the refrigerating process is constant, which has a promising potential for competing the 'intermittent' cycle reported before. Through improving the refrigerant performance of heat and mass transfer in the adsorbent bed, the refrigeration cycle has been advanced from the aspect of utilization of the thermal energy from low-temperature level resources. In addition, it is shown that the commercial solar powered refrigerator will be existent in the near future.

Zheng, A.; Gu, J.

2006-01-01T23:59:59.000Z

335

Demand Response Opportunities in Industrial Refrigerated Warehouses in  

NLE Websites -- All DOE Office Websites (Extended Search)

Response Opportunities in Industrial Refrigerated Warehouses in Response Opportunities in Industrial Refrigerated Warehouses in California Title Demand Response Opportunities in Industrial Refrigerated Warehouses in California Publication Type Conference Paper LBNL Report Number LBNL-4837E Year of Publication 2011 Authors Goli, Sasank, Aimee T. McKane, and Daniel Olsen Conference Name 2011 ACEEE Summer Study on Energy Efficiency in Industry Date Published 08/2011 Conference Location Niagara Falls, NY Keywords market sectors, openadr, refrigerated warehouses Abstract Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

336

L&E: Refrigerated Display Case | The Better Buildings Alliance  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Adopt the Lighting & Electrical » Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs The LED Refrigerated Display Case Lighting Specification delivers nearly 50% energy savings compared to typical display case lighting. If all retail refrigerated display cases switched today to LED systems, over 2.1 TWh of electricity could be saved annually. LED Refrigerated Display Case Lighting Specification

337

Method of removing an immiscible lubricant from a refrigeration system and apparatus for same  

DOE Patents (OSTI)

A method of separating an immiscible lubricant from a liquid refrigerant in a refrigerating system including a compressor, a condenser, an expansion device and an evaporator, wherein the expansion device is connected to the condenser by a liquid refrigerant flow line for liquid refrigerant and immiscible lubricant. The method comprising slowing the rate of flow of the liquid refrigerant and immiscible lubricant between the condenser and the expansion device such that the liquid refrigerant and the immiscible lubricant separate based upon differences in density. The method also comprises collecting the separated immiscible lubricant in a collection chamber in fluid communication with the separated immiscible lubricant. Apparatus for performing the method is also disclosed.

Spauschus, Hans O. (Stockbridge, GA); Starr, Thomas L. (Roswell, GA)

1999-01-01T23:59:59.000Z

338

The Cost of Helium Refrigerators and Coolers for Superconducting Devices as a Function of Cooling at 4 K  

E-Print Network (OSTI)

as a function of design refrigeration at 4.5 K. The costsk$) versus the Design Refrigeration at 4.2 K (W) THECoolers versus the Design Refrigeration at 4.2 K. (The open

Green, Michael A.

2008-01-01T23:59:59.000Z

339

Vapor Precooling in a Pulse Tube Liquefier  

Science Conference Proceedings (OSTI)

... to medium liquefaction plants (20 W to 1 kW refrigeration capacity) for local cryogen liquefaction in the aerospace, military, and commercial sector. ...

2010-12-13T23:59:59.000Z

340

Dilution Refrigeration of Multi-Ton Cold Masses  

E-Print Network (OSTI)

Dilution refrigeration is the only means to provide continuous cooling at temperatures below 250 mK. Future experiments featuring multi-ton cold masses require a new generation of dilution refrigeration systems, capable of providing a heat sink below 10 mK at cooling powers which exceed the performance of present systems considerably. This thesis presents some advances towards dilution refrigeration of multi-ton masses in this temperature range. A new method using numerical simulation to predict the cooling power of a dilution refrigerator of a given design has been developed in the framework of this thesis project. This method does not only allow to take into account the differences between an actual and an ideal continuous heat exchanger, but also to quantify the impact of an additional heat load on an intermediate section of the dilute stream. In addition, transient behavior can be simulated. The numerical model has been experimentally verified with a dilution refrigeration system which has been designed, ...

Wikus, P; CERN. Geneva

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Counter-Top Thermoacoustic Refrigerator- An Experimental Investigation  

SciTech Connect

Thermoacoustic phenomenon is a new alternative refrigeration technology. Though design and fabrication is complex for getting the desired effect, it is environmentally friendly and successful system showed that it is relatively easy to run compared to the traditional vapor compression refrigeration system. Currently, theories supporting the thermoacoustic refrigeration systems are yet to be comprehensive to make them commercially viable. Theoretical, experimental, and numerical studies are being done to address the thermodynamics-acoustics interactions. In this study, experimental investigations were completed to test the feasibility of the practical use of a thermoacoustic refrigerator in its counter-top form for future specific application. The system was designed and fabricated based on linear acoustic theory. Acoustic power was given by a loud speaker and thermoacoustic effects were measured in terms of the cooling effects produced at resonanance. Investigations showed that discrepancies between designed and working resonance frequency exist. Thermoacoutic cooling improved at a certain frequency, achieved when the working frequency was varied away from the design frequency. A cooling effect of 4.8 K below the ambient temperature of 23.3 deg. C was obtained from the counter-top thermoacoustic system. This system uses no refrigerants and no compressor to generate the cooling effect, a potential to be further investigated for a practical system.

Anwar, Mahmood; Ghazali, Normah Mohd [Department of Thermo-Fluids, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia Skudai 81310, Johor (Malaysia)

2010-06-28T23:59:59.000Z

342

Novel Tube-in-Tube System Simplifies Subsurface Fluid Sampling ...  

* Retrieval of single or multiphase high-purity samples More Information Freifeld, B. M., 2009, “The U-tube: a new paradigm in borehole fluid sampling ...

343

Solutions for Summer Electric Power Shortages: Demand Response and its Applications in Air Conditioning and Refrigerating Systems  

E-Print Network (OSTI)

LBNL-63806 Refrigeration, Air Conditioning, & Electric Powerand its Applications in Air Conditioning and Refrigeratingand its applications in Air Conditioning and refrigerating

Han, Junqiao; Piette, Mary Ann

2008-01-01T23:59:59.000Z

344

Energy Efficiency Evaluation of Refrigeration Technologies in Combined Cooling, Heating and Power Systems  

E-Print Network (OSTI)

With development of absorption refrigeration technology, the cooling requirement can be met using various optional refrigeration technologies in a CCHP system, including compression refrigeration, steam double-effect absorption refrigeration, steam single-effect absorption refrigeration, flue gas absorption refrigeration and hot water absorption refrigeration, etc. As a universal criterion, the COP coefficient cannot reflect the difference in availability of driving energy for different chillers. Exergy efficiency of optional chillers in CCHP system was analyzed and compared, which can be regarded as an important reference criterion in comparison of energy efficiency. Furthermore, a new index, relative electricity saving ratio, was put forward for evaluating end energy efficiency of all kinds of chillers in a CCHP system, which indicates actual energy or electricity saving ratio for different absorption chillers with various parameters in contrast to the reference electricity-driven refrigeration scheme.

Zuo, Z.; Hu, W.

2006-01-01T23:59:59.000Z

345

The Performance Analysis of a Quantum Brayton Refrigeration Cycle with an Ideal Bose Gas  

Science Conference Proceedings (OSTI)

A Brayton refrigeration cycle using an ideal Bose gas as the working substance is simply referred to as a quantum Brayton refrigeration cycle, which consists of two constant-pressure and two adiabatic processes. The influence of quantum degeneracy on ...

Bihong Lin; Jincan Chen

2003-05-01T23:59:59.000Z

346

Ion plated electronic tube device  

DOE Patents (OSTI)

An electronic tube and associated circuitry which is produced by ion plating techniques. The process is carried out in an automated process whereby both active and passive devices are produced at very low cost. The circuitry is extremely reliable and is capable of functioning in both high radiation and high temperature environments. The size of the electronic tubes produced are more than an order of magnitude smaller than conventional electronic tubes.

Meek, T.T.

1983-10-18T23:59:59.000Z

347

Field Guide: Boiler Tube Failure  

Science Conference Proceedings (OSTI)

In conventional and combined-cycle plants, boiler tube failures (BTFs) have been the main availability problem for as long as reliable statistics have been kept for each generating source. The three volumes of the Electric Power Research Institute (EPRI) report Boiler and Heat Recovery Steam Generator Tube Failures: Theory and Practice (1012757) present an in-depth discussion of the various BTF and degradation mechanisms, providing plant owners and operators with the technical basis to address tube failu...

2009-12-22T23:59:59.000Z

348

DOE Closes Investigation into Energy Efficiency of Viking Refrigerator |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Closes Investigation into Energy Efficiency of Viking Closes Investigation into Energy Efficiency of Viking Refrigerator DOE Closes Investigation into Energy Efficiency of Viking Refrigerator November 9, 2010 - 7:30pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Viking Range Corporation's refrigerator-freezer model VCSB542. The Department initiated this investigation in response to allegations that the model failed to meet federal energy efficiency standards. After reviewing data provided by Viking for this model, the Department issued a testing demand on June 16, 2010 and initially tested four units, one of which was defective and replaced by a fifth unit. The test results showed that two Viking units failed the federal energy standard for maximum energy use, while two passed. Because of the wide variation in the

349

DOE Closes Investigation into Energy Efficiency of Viking Refrigerator |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

into Energy Efficiency of Viking into Energy Efficiency of Viking Refrigerator DOE Closes Investigation into Energy Efficiency of Viking Refrigerator November 9, 2010 - 7:30pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Viking Range Corporation's refrigerator-freezer model VCSB542. The Department initiated this investigation in response to allegations that the model failed to meet federal energy efficiency standards. After reviewing data provided by Viking for this model, the Department issued a testing demand on June 16, 2010 and initially tested four units, one of which was defective and replaced by a fifth unit. The test results showed that two Viking units failed the federal energy standard for maximum energy use, while two passed. Because of the wide variation in the

350

South Africa Sectoral Study on Climate and Refrigeration Technology in  

Open Energy Info (EERE)

South Africa Sectoral Study on Climate and Refrigeration Technology in South Africa Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Jump to: navigation, search Name South Africa-Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics Low emission development planning, -LEDS, -NAMA, Market analysis Website http://www.giz.de/en/ Program Start 2010 Program End 2012 Country South Africa Southern Africa

351

India Sectoral Study on Climate and Refrigeration Technology in Developing  

Open Energy Info (EERE)

India Sectoral Study on Climate and Refrigeration Technology in Developing India Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Jump to: navigation, search Name India-Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics Low emission development planning, -LEDS, -NAMA, Market analysis Website http://www.giz.de/en/ Program Start 2010 Program End 2012 Country India Southern Asia References Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ)[1]

352

Mexico Sectoral Study on Climate and Refrigeration Technology in Developing  

Open Energy Info (EERE)

Mexico Sectoral Study on Climate and Refrigeration Technology in Developing Mexico Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Jump to: navigation, search Name Mexico-Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics Low emission development planning, -LEDS, -NAMA, Market analysis Website http://www.giz.de/en/ Program Start 2010 Program End 2012 Country Mexico Central America References Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ)[1]

353

Sectoral Study on Climate and Refrigeration Technology in Developing  

Open Energy Info (EERE)

Study on Climate and Refrigeration Technology in Developing Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Jump to: navigation, search Name Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics Low emission development planning, -LEDS, -NAMA, Market analysis Website http://www.giz.de/en/ Program Start 2010 Program End 2012 Country India, Mexico, South Africa, Thailand Southern Asia, Central America, Southern Africa, South-Eastern Asia

354

Energy Efficiency Standards for Refrigerators in Brazil: A Methodology for  

Open Energy Info (EERE)

Energy Efficiency Standards for Refrigerators in Brazil: A Methodology for Energy Efficiency Standards for Refrigerators in Brazil: A Methodology for Impact Evaluation Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Energy Efficiency Standards for Refrigerators in Brazil: A Methodology for Impact Evaluation Focus Area: Energy Efficiency Topics: Potentials & Scenarios Website: www.scribd.com/doc/34712276/Energy-efficiency-standards-for-refrigerat Equivalent URI: cleanenergysolutions.org/content/energy-efficiency-standards-refrigera Language: English Policies: Regulations Regulations: "Appliance & Equipment Standards and Required Labeling,Emissions Standards" is not in the list of possible values (Agriculture Efficiency Requirements, Appliance & Equipment Standards and Required Labeling, Audit Requirements, Building Certification, Building Codes, Cost Recovery/Allocation, Emissions Mitigation Scheme, Emissions Standards, Enabling Legislation, Energy Standards, Feebates, Feed-in Tariffs, Fuel Efficiency Standards, Incandescent Phase-Out, Mandates/Targets, Net Metering & Interconnection, Resource Integration Planning, Safety Standards, Upgrade Requirements, Utility/Electricity Service Costs) for this property.

355

Quantum spins mimic refrigerator magnets - Argonne National Laboratories,  

NLE Websites -- All DOE Office Websites (Extended Search)

Highlights > Quantum spins mimic refrigerator Highlights > Quantum spins mimic refrigerator magnets Quantum spins mimic refrigerator magnets By Joseph Bernstein * October 11, 2012 The behavior of magnetic moments in metal oxides such as layered iridium is dominated by strong spin-orbit coupling effects. In layered compounds such as Sr3Ir2O7 (shown on the left), the direction of these moments (blue arrows) is controlled at the quantum level by dipolar interactions that are akin to those of classical bar magnets. Another outcome is an unprecedented 'magnon gap' (shown at right), which was measured at the Argonne Advanced Photon Source and reveals that these underlying dipolar magnetic interactions are extremely strong. Current electronic devices depend on manipulating charge. Alternative approaches may rely on not only charge but also the spin of electrons.

356

Thailand Sectoral Study on Climate and Refrigeration Technology in  

Open Energy Info (EERE)

Thailand Sectoral Study on Climate and Refrigeration Technology in Thailand Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Jump to: navigation, search Name Thailand-Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics Low emission development planning, -LEDS, -NAMA, Market analysis Website http://www.giz.de/en/ Program Start 2010 Program End 2012 Country Thailand South-Eastern Asia References Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ)[1]

357

Frost sensor for use in defrost controls for refrigeration  

DOE Patents (OSTI)

An apparatus and method for measuring the total thermal resistance to heat flow from the air to the evaporative cooler fins of a refrigeration system. The apparatus is a frost sensor that measures the reduction in heat flow due to the added thermal resistance of ice (reduced conduction) as well as the reduction in heat flow due to the blockage of airflow (reduced convection) from excessive ice formation. The sensor triggers a defrost cycle when needed, instead of on a timed interval. The invention is also a method for control of frost in a system that transfers heat from air to a refrigerant along a thermal path. The method involves measuring the thermal conductivity of the thermal path from the air to the refrigerant, recognizing a reduction in thermal conductivity due to the thermal insulation effect of the frost and due to the loss of airflow from excessive ice formation; and controlling the defrosting of the system.

French, Patrick D. (ADA Technologies, Inc. 8100 Shaffer Pkwy., Suite 130, Littleton, CO 80127-4107); Butz, James R. (ADA Technologies, Inc. 8100 Shaffer Pkwy., Suite 130, Littleton, CO 80127-4107); Veatch, Bradley D. (ADA Technologies, Inc. 8100 Shaffer Pkwy., Suite 130, Littleton, CO 80127-4107); O' Connor, Michael W. (ADA Technologies, Inc. 8100 Shaffer Pkwy., Suite 130, Littleton, CO 80127-4107)

2002-01-01T23:59:59.000Z

358

Physics Out Loud - Photomultiplier Tube  

NLE Websites -- All DOE Office Websites (Extended Search)

Particle Resonance Previous Video (Particle Resonance) Physics Out Loud Main Index Next Video (Proton) Proton Photomultiplier Tube One way we "see" the sub-atomic particles in our...

359

DOE/EA-1643: Environmental Assessment for 10 CFR 431 Commercial Refrigeration Equipment (December 2008)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ENVIRONMENTAL ASSESSMENT FOR ENVIRONMENTAL ASSESSMENT FOR 10 CFR Part 431 Energy Conservation Program for Commercial and Industrial Equipment: Energy Conservation Standards for Commercial Ice-Cream Freezers; Self-Contained Commercial Refrigerators, Commercial Freezers, and Commercial Refrigerator- Freezers without Doors; and Remote Condensing Commercial Refrigerators, Commercial Freezers, and Commercial Refrigerator-Freezers December 2008 CHAPTER 16. ENVIRONMENTAL IMPACT ANALYSIS TABLE OF CONTENTS 16.1 INTRODUCTION ............................................................................................................ 16-1 16.2 AIR QUALITY ANALYSIS ............................................................................................ 16-1

360

Refrigerant Properties: Commercial Cooling Update Issue 5, Rev. 6, September 1999  

Science Conference Proceedings (OSTI)

This Update describes the properties of existing and proposed refrigerants. Because many of these properties are measured by techniques that are still evolving, some of the values shown may change. The data included are from the most recently published sources. Properties covered include: ozone depletion potential, global warming potential, refrigeration capacity, energy efficiency, flammability, exposure limits,and refrigerant blends. A table conveniently compares traditional refrigerants in use, new re...

1999-09-30T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Novel La(Fe,Si) 13 -Based Composites for Magnetic Refrigeration  

Science Conference Proceedings (OSTI)

Nanocomposite Alloy Design for High Frequency Power Conversion Applications · Novel La(Fe,Si)13-Based Composites for Magnetic Refrigeration.

362

Demand Response Opportunities in Industrial Refrigerated Warehouses in California  

Science Conference Proceedings (OSTI)

Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

Goli, Sasank; McKane, Aimee; Olsen, Daniel

2011-06-14T23:59:59.000Z

363

Magnetic refrigeration apparatus with belt of ferro or paramagnetic material  

DOE Patents (OSTI)

A magnetic refrigerator operating in the 12 to 77 K range utilizes a belt which carries ferromagnetic or paramagnetic material and which is disposed in a loop which passes through the center of a solenoidal magnet to achieve cooling. The magnetic material carried by the belt, which can be blocks in frames of a linked belt, can be a mixture of substances with different Curie temperatures arranged such that the Curie temperatures progressively increase from one edge of the belt to the other. This magnetic refrigerator can be used to cool and liquefy hydrogen or other fluids.

Barclay, J.A.; Stewart, W.F.; Henke, M.D.; Kalash, K.E.

1986-04-03T23:59:59.000Z

364

TubeTagger - YouTube-based Concept Detection  

Science Conference Proceedings (OSTI)

We present TubeTagger, a concept-based video retrieval system that exploits web video as an information source. The system performs a visual learning on YouTube clips (i. e., it trains detectors for semantic concepts like "soccer" or "windmill"), and ...

Adrian Ulges; Markus Koch; Damian Borth; Thomas M. Breuel

2009-12-01T23:59:59.000Z

365

Influence of External Heat Source on Transcritical CO2 Refrigeration System  

Science Conference Proceedings (OSTI)

Synthetic refrigerants such as CFCs and HCFCs are harmful to the ozone and could cause greenhouse effect. Refrigerant alternatives research is very urgent. CO2 as a natural working fluid has zero ODP and its GWP=1, is receiving more and more attention ... Keywords: Coefficient of Performance, Experimental Investigation, Heat Source, Transcritical CO2 Refrigeration System

Liu Yingfu; Xiao Jian; Jin Guangya

2012-07-01T23:59:59.000Z

366

Design and Analysis of a Nested Halbach Permanent Magnet Magnetic Refrigerator  

E-Print Network (OSTI)

Design and Analysis of a Nested Halbach Permanent Magnet Magnetic Refrigerator by Armando Tura BEng Committee Design and Analysis of a Nested Halbach Permanent Magnet Magnetic Refrigerator by Armando Tura with the potential to create efficient and compact refrigeration devices is an active magnetic regenerative

Victoria, University of

367

System design and simulation of constant temperature box using semiconductor refrigeration device  

Science Conference Proceedings (OSTI)

This paper presents the variation law of temperature in three-dimensional space, which is cooled by the refrigeration provided by the cold side of a semiconductor. The mathematical model of the temperature field of the semiconductor refrigeration ... Keywords: constant temperature box, forced convection, mathematical modelling, numerical simulation, semiconductor refrigeration, system design

Hui Zhang; Kuang-Chao Fan; Jun Wang

2010-03-01T23:59:59.000Z

368

Electric equipment providing space conditioning, water heating, and refrigeration consumes 12.5% of the nation's  

E-Print Network (OSTI)

-acceptable refrigerants. Whether involving design of specific new products or refriger- ants to which the entire industryElectric equipment providing space conditioning, water heating, and refrigeration consumes 12 are the heart of air conditioners, heat pumps, chillers, supermarket refrigeration systems, and more. Global use

Oak Ridge National Laboratory

369

Chapter 6: Refrigeration Process Control: A Formal Design Approach 111 66.. RREEFFRRIIGGEERRAATTIIOONN PPRROOCCEESSSS  

E-Print Network (OSTI)

Chapter 6: Refrigeration Process Control: A Formal Design Approach 111 66 are summarised in Table 6.1 below. #12;Chapter 6: Refrigeration Process Control: A Formal Design Approach 112 on #12;Chapter 6: Refrigeration Process Control: A Formal Design Approach 113 the steady state gain

Skogestad, Sigurd

370

Chapter 3: Refrigeration Process Control: Case Study Model 42 33.. RREEFFRRIIGGEERRAATTIIOONN PPRROOCCEESSSS  

E-Print Network (OSTI)

are needed, and the required allowances in design are made to account for this. #12;Chapter 3: RefrigerationChapter 3: Refrigeration Process Control: Case Study Model 42 33.. RREEFFRRIIGGEERRAATTIIOONN-stage refrigeration system case study. It describes in detail the mathematical model developed, highlighting

Skogestad, Sigurd

371

Chapter 5: Refrigeration Process Control: A Pragmatic Design Approach 75 55.. RREEFFRRIIGGEERRAATTIIOONN PPRROOCCEESSSS  

E-Print Network (OSTI)

Chapter 5: Refrigeration Process Control: A Pragmatic Design Approach 75 55. #12;Chapter 5: Refrigeration Process Control: A Pragmatic Design Approach 76 This leaves up to three from a different perspective #12;Chapter 5: Refrigeration Process Control: A Pragmatic Design Approach

Skogestad, Sigurd

372

Proceedings of the 1993 non-fluorocarbon insulation, refrigeration and air conditioning technology workshop  

SciTech Connect

Sessions included: HFC blown polyurethanes, carbon dioxide blown foam and extruded polystyrenes, plastic foam insulations, evacuated panel insulation, refrigeration and air conditioning, absorption and adsorption and stirling cycle refrigeration, innovative cooling technologies, and natural refrigerants. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.

Not Available

1994-09-01T23:59:59.000Z

373

Application Availability of Insulation Heat of the Terrace in a Rebuilt Refrigerator  

E-Print Network (OSTI)

Dealing with the terrace in rebuilt refrigerators influences the performance characteristics, performance safety and construction costs. This paper researches the heat transfer of the terrace of the rebuilt refrigerator by the numerical method, analyzes the temperature distribution of the terrace, and supplies guidance for rebuilding refrigerators.

Qu, C.; Sun, Y.; Chen, Z.

2006-01-01T23:59:59.000Z

374

Explosive welding of a tube into a tube sheet  

DOE Patents (OSTI)

A cartridge containing an explosive charge is placed within a tube assembled within a tube sheet. The charge is detonated through use of a detonator cord containing a minimum but effective amount of explosive material. The cord is contained inside a tubular shield throughout most of its length within the cartridge. A small length of the cord extends beyond the tubular shield to contact and detonate the explosive charge in its rear portion near the cartridge base. The cartridge base is provided of substantial mass and thickness in respect to side and front walls of the cartridge to minimize bulging beyond the rear face of the tube sheet. For remote activation an electrically activated detonator of higher charge density than the cord is attached to the cord at a location spaced from the tube sheet, cartridge and tube.

Green, Sheryll C. (London, OH); Linse, Vonne D. (Columbus, OH)

1978-10-03T23:59:59.000Z

375

Coiled tubing - Operations and services  

Science Conference Proceedings (OSTI)

Drilling with a continuous (rather than jointed) drill string is an old concept that is gaining new attention as a result of recent advances made in coiled tubing and drilling technology. The development of larger diameter, reliable, high-strength coiled tubing and smaller diameter, positive displacement motors, orienting tools, surveying systems and fixed cutting drill bits have given drilling with a continuous drill string a capability that was previously unattainable. Like its many other uses, (e.g., squeeze cementing, wellbore cleanouts, flow initiation, logging) the continuity of coiled tubing gives it several advantages over conventional drill strings. These include: drilling underbalanced safely, significantly reduced trip time, continuous circulation, smaller surface requirements. Coiled tubing drilling operations have smaller surface lease requirements than most conventional rigs due to the smaller footprint of the coiled tubing unit and associated equipment. Current coiled tubing drilling operations have the following limitations: conventional rig assistance is required for well preparation; conventional rigs must assist in running long protective and production casing strings or liners; hole sizes are smaller; working depth capabilities are shallower, coiled tubing life is less. This paper goes on to discuss the history of continuous drill strings and includes information on tubing units, circulating systems, drilling fluids, well control systems, downhole tools, orientation tools, and bottomhole assemblies. It then gives a cost comparison and an application of this type of drilling.

Gronseth, J.M. (Imperial Oil Resources Ltd., Calgary, Alberta (Canada))

1993-04-01T23:59:59.000Z

376

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve  

E-Print Network (OSTI)

The effect of the improper charging on steady state and cyclic performance (capacity, EER, power consumption, SEER, and coefficient of degradation) of a residential air conditioner which utilized a thermal expansion valve was investigated. This study was the continuation of ESL/CON/88-1 performed by Mohsen Farzad and Dennis O'Neal. A fully charged condition was established as a base case. The full charge was obtained by charging the unit to the subcooling specified by the manufacturer for a specific indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 40%, 30%, 20%, 15%, 10%, and 5% undercharging and 5%, 10%, 15%, and 20% overcharging of refrigerant by mass. The fully charged tests were compared to those for under and overcharging. The performance of the unit was evaluated as a function of charge as well as at four outdoor room temperatures (82°F, 90°F, 95°F, and 100°F). As the outdoor temperature increased, the total capacity and EER dropped. The maximum total capacity, EER, and SEER were found at 10% undercharging (12 6 oz). The capacity and efficiency (EER and SEER) of the unit were found to be less sensitive to under/overcharging than the unit with a capillary tube expansion previously studied. Other data such as refrigerant flow rate, sensible heat ratio, superheat and subcooling were also presented.

Farzad, M.; O'Neal, D. L.

1989-01-01T23:59:59.000Z

377

The Quantum Absorption Refrigerator Amikam Levy and Ronnie Kosloff  

E-Print Network (OSTI)

source to replace mechanical work for driving a heat pump [1]. The first device was developed in 1850 an ab- sorption refrigerator with no moving parts [2]. This idea has been incorporated recently c J h P Tc Th Tw - - - 0 FIG. 1: The quantum trickle: A quantum heat pump des- ignated

Kosloff, Ronnie

378

COMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATION SYSTEMS  

E-Print Network (OSTI)

and the assumed electrical energy cost is $0.04 per kWh.cost (the cost is given in US$ per kWh at 80.4°K) andThe cost of nitrogen refrigeration given in $ per kWh at

green, M.A.

2011-01-01T23:59:59.000Z

379

Procurement and commissioning of the CHL refrigerator at CEBAF  

SciTech Connect

The CEBAF Central Helium Liquefier (CHL) provides 2K refrigeration to the 338 superconducting niobium cavities in two 400 MeV linacs and one 45 MeV injector. The CHL consists of three first stage and three second stage compressors, a 4.5K cold box, a 2K cold box, liquid and gaseous helium storage, liquid nitrogen storage, and transfer lines. Figure 1 presents a block diagram of the CHL refrigerator. The system was designed to provide 4.8 kW of primary refrigeration at 2K, 12 kW of shield refrigeration at 45K for the linac cryomodules, and 10 g/s of liquid flow for the end stations. In April 1994, stable 2K operation of the previously uncommissioned cold compressors was achieved. The cold compressors are a cold vacuum pump with an inlet temperature of circa 3.0K. These compressors operate on magnetic bearing,s and therefore eliminate the possibility of contamination due to any air leaks into the system. Operational data and commissioning experience as they relate to the warm gaseous helium compressors, turbines, instrumentation and control, and the cold compressors are presented.

Chronis, W.C.; Arenius, D.M.; Bevins, B.S.; Ganni, V.; Kashy, D.H.; Keesee, M.M.; Reid, T.R.; Wilson, J.D.

1996-08-01T23:59:59.000Z

380

Microprocessor-based controller for a liquid hydrogen target refrigerator  

DOE Green Energy (OSTI)

A microprocessor-based cryogenic refrigerator controller developed at the Los Alamos Scientific Laboratory provides automatic cooldown and subsequent monitoring of liquid hydrogen targets. The controller performs the initial cooldown of the cryogenic system and provides continuous monitoring of the important system parameters. An alarm is sounded to summon an operator in the event of any parameter exceeding predetermined limits.

Gjovig, A.J.; Little, J.D.; Novak, J.K.

1978-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Speed Control in Industrial Refrigeration: Theory, Application & Case Studies  

E-Print Network (OSTI)

It is often standard practice in the field of industrial refrigeration to design and operate systems with little regard toward part-load performance. This approach is understandable, whether viewed from the standpoint of the design engineer, plant manager or chief operator. As long a space temperature and production rates are maintained during peak periods, the refrigeration system is viewed as operating "correctly". The truth is, most refrigeration systems spend some, if not most operating hours at reduced capacity. Screw compressors back off slide valves, evaporator coils utilize back-pressure regulators (BPRs) or liquid solenoids, and condensers cycle fans. Unfortunately, these control methods do not provide the maximum attainable reduction in brake horsepower (BHP) as refrigeration capacity is reduced. This paper will discuss the application of variable speed drive (VSD, also called "variable frequency drive", "adjustable speed drive", "inverter", or simply "freq. drive") technology to capacity control of screw compressors, evaporator fans, and condenser fans. As shown through theory and case study, speed control of these components provides maximum flexibility, control and energy efficiency.

Wilcox, M. H.

1995-04-01T23:59:59.000Z

382

Optimal Sequencing of Central Refrigeration Equipment in an Industrial Plant  

E-Print Network (OSTI)

A model was developed to find a viable solution to the problem of selecting the optimal sequence of refrigeration equipment (chillers, cooling towers, pumps) to operate in a Central Utility Plant. The optimal equipment sequence is that sequence which has the lowest energy cost to operate at a given plant cooling load and outside air wet bulb temperature. and satisfies all the constraints associated with the refrigeration system. Selection of the optimal equipment sequence is very difficult given the complexity of the refrigeration system and the dynamic nature of the plant cooling load. As a solution a computer program was developed to generate optimal equipment sequences to operate for combinations of a wide range of plant cooling loads and outside air wet bulb temperatures. Analysis of the solution identified the need for a retrofit project to remove "vital" constraints in order to improve the refrigeration system's performance. The solution to the problem was then incorporated in the operating procedures for the Central Utility Plant.

Fiorino, D. P.; Priest, J. W.

1986-01-01T23:59:59.000Z

383

Triple loop heat exchanger for an absorption refrigeration system  

DOE Patents (OSTI)

A triple loop heat exchanger for an absorption refrigeration system is disclosed. The triple loop heat exchanger comprises portions of a strong solution line for conducting relatively hot, strong solution from a generator to a solution heat exchanger of the absorption refrigeration system, conduit means for conducting relatively cool, weak solution from the solution heat exchanger to the generator, and a bypass system for conducting strong solution from the generator around the strong solution line and around the solution heat exchanger to an absorber of the refrigeration system when strong solution builds up in the generator to an undesirable level. The strong solution line and the conduit means are in heat exchange relationship with each other in the triple loop heat exchanger so that, during normal operation of the refrigeration system, heat is exchanged between the relatively hot, strong solution flowing through the strong solution line and the relatively cool, weak solution flowing through the conduit means. Also, the strong solution line and the bypass system are in heat exchange relationship in the triple loop heat exchanger so that if the normal flow path of relatively hot, strong solution flowing from the generator to an absorber is blocked, then this relatively, hot strong solution which will then be flowing through the bypass system in the triple loop heat exchanger, is brought into heat exchange relationship with any strong solution which may have solidified in the strong solution line in the triple loop heat exchanger to thereby aid in desolidifying any such solidified strong solution.

Reimann, Robert C. (Lafayette, NY)

1984-01-01T23:59:59.000Z

384

Designing Augmented Refrigerator Magnets Rachel Eardley, Laurel Swan  

E-Print Network (OSTI)

Designing Augmented Refrigerator Magnets Rachel Eardley, Laurel Swan , Abi Sellen Alex S. Taylor In this poster we present the conceptual designs for several augmented fridge magnets, each illustrative of a larger number of concepts being explored and implemented. The designs have been informed through ongoing

Hunt, Galen

385

The Energy-Saving Design Practices for Direct Cooling Refrigerator  

Science Conference Proceedings (OSTI)

The area of evaporator on cold storage chamber was added under a constant total evaporator area. Composite and stereoscopic structure with laminated exchanger flake was used on evaporator of freezing chamber. Wing - flakes were fixed outside the refrigerant ... Keywords: refrigerantion, energy-saving, condensor, evaporator

Cai Yingling; Zhang Hua; Chen Shuai; Li Gang; Xia Peng

2009-10-01T23:59:59.000Z

386

Widget:YouTube | Open Energy Information  

Open Energy Info (EERE)

icon Widget:YouTube Jump to: navigation, search This widget displays a YouTube video. Parameters id - the YouTube video id (this is the v parameter or the code at the end...

387

Water-storage-tube systems. Final report  

DOE Green Energy (OSTI)

Passive solar collection/storage/distribution systems were surveyed, designed, fabricated, and mechanically and thermally tested. The types studied were clear and opaque fiberglass tubes, metal tubes with plastic liners, and thermosyphoning tubes. (MHR)

Hemker, P.

1981-12-24T23:59:59.000Z

388

Floating Refrigerant Loop Based on R-134a Refrigerant Cooling of High-Heat Flux Electronics  

SciTech Connect

The Oak Ridge National Laboratory (ORNL) Power Electronics and Electric Machinery Research Center (PEEMRC) have been developing technologies to address the thermal issues associated with hybrid vehicles. Removal of the heat generated from electrical losses in traction motors and their associated power electronics is essential for the reliable operation of motors and power electronics. As part of a larger thermal control project, which includes shrinking inverter size and direct cooling of electronics, ORNL has developed U.S. Patent No. 6,772,603 B2, ''Methods and Apparatus for Thermal Management of Vehicle Systems and Components'' [1], and patent pending, ''Floating Loop System for Cooling Integrated Motors and Inverters Using Hot Liquid Refrigerant'' [2]. The floating-loop system provides a large coefficient of performance (COP) for hybrid-drive component cooling. This loop (based on R-134a) is integrated with a vehicle's existing air-conditioning (AC) condenser, which dissipates waste heat to the ambient air. Because the temperature requirements for cooling of power electronics and electric machines are not as low as that required for passenger compartment air, this adjoining loop can operate on the high-pressure side of the existing AC system. This arrangement also allows the floating loop to run without the need for the compressor and only needs a small pump to move the liquid refrigerant. For the design to be viable, the loop must not adversely affect the existing system. The loop should also provide a high COP, a flat-temperature profile, and low-pressure drop. To date, the floating-loop test prototype has successfully removed 2 kW of heat load in a 9 kW automobile passenger AC system with and without the automotive AC system running. The COP for the tested floating-loop system ranges from 40-45, as compared to a typical AC system COP of about 2-4. The estimated required waste-heat load for future hybrid applications is 5.5 kW and the existing system could be easily scaleable for this larger load.

Lowe, K.T.

2005-10-07T23:59:59.000Z

389

Floating Refrigerant Loop Based on R-134a Refrigerant Cooling of High-Heat Flux Electronics  

SciTech Connect

The Oak Ridge National Laboratory (ORNL) Power Electronics and Electric Machinery Research Center (PEEMRC) have been developing technologies to address the thermal issues associated with hybrid vehicles. Removal of the heat generated from electrical losses in traction motors and their associated power electronics is essential for the reliable operation of motors and power electronics. As part of a larger thermal control project, which includes shrinking inverter size and direct cooling of electronics, ORNL has developed U.S. Patent No. 6,772,603 B2, ''Methods and Apparatus for Thermal Management of Vehicle Systems and Components'' [1], and patent pending, ''Floating Loop System for Cooling Integrated Motors and Inverters Using Hot Liquid Refrigerant'' [2]. The floating-loop system provides a large coefficient of performance (COP) for hybrid-drive component cooling. This loop (based on R-134a) is integrated with a vehicle's existing air-conditioning (AC) condenser, which dissipates waste heat to the ambient air. Because the temperature requirements for cooling of power electronics and electric machines are not as low as that required for passenger compartment air, this adjoining loop can operate on the high-pressure side of the existing AC system. This arrangement also allows the floating loop to run without the need for the compressor and only needs a small pump to move the liquid refrigerant. For the design to be viable, the loop must not adversely affect the existing system. The loop should also provide a high COP, a flat-temperature profile, and low-pressure drop. To date, the floating-loop test prototype has successfully removed 2 kW of heat load in a 9 kW automobile passenger AC system with and without the automotive AC system running. The COP for the tested floating-loop system ranges from 40-45, as compared to a typical AC system COP of about 2-4. The estimated required waste-heat load for future hybrid applications is 5.5 kW and the existing system could be easily scaleable for this larger load.

Lowe, K.T.

2005-10-07T23:59:59.000Z

390

Reduced Effective Model for Condensation in Slender Tubes with Rotational Symmetry, Obtained by Generalized Dimensional Analysis  

E-Print Network (OSTI)

Experimental results for condensation in compact heat exchangers show that the heat transfer due to condensation is significantly better compared to classical heat exchangers, especially when using R134a instead of water as the refrigerant. This suggests that surface tension plays a role. Using generalized dimensional analysis we derive reduced model equations and jump conditions for condensation in a vertical tube with cylindrical cross section. Based on this model we derive a single ordinary differential equation for the thickness of the condensate film as function of the tube axis. Our model agrees well with commonly used models from existing literature. It is based on the physical dimensions of the problem and has greater geometrical flexibility.

Dziubek, Andrea

2011-01-01T23:59:59.000Z

391

Tubing drain valve  

SciTech Connect

A method is described for operating a valve means. The valve means comprises a tubular piston movable within a tubular member suitable for use in a borehole pipe string to open and close a port through the wall of the tubular member. The method comprises: biassing the valve means in its closed position; pressurizing the interior of the piston to a predetermined pressure to overcome the biassing closed force and to actuate the valve means to its open position; biassing the valve means to its open position; and actuating the valve means to its closed position by engaging a first arm of a dog pivotally mounted on the piston with an engaging means insertable through the interior of the tubular piston; moving the piston relative to the tubular member; rotating the dog about its pivot to bring a second arm of the dog into contact with a detent in the tubular member; and applying sufficient force to the first arm to continue rotating the dog about the pivot, while engaging the detent with the second arm of the dog, in order to overcome the biassing open force to actuate the valve means to its closed position. A tubing drain valve suitable for use in a borehole pipe string, comprising: a sub suitable for incorporating within a borehole pipe string; and a port between the interior and the exterior of the sub; and valve means for opening and closing the port.

Soderberg, P.B.

1987-02-24T23:59:59.000Z

392

Method of making straight fuel cell tubes  

DOE Patents (OSTI)

A method and an apparatus for making straight fuel cell tubes are disclosed. Extruded tubes comprising powders of fuel cell material and a solvent are dried by rotating the extruded tubes. The rotation process provides uniform circumferential drying which results in uniform linear shrinkage of the tubes. The resultant dried tubes are very straight, thereby eliminating subsequent straightening steps required with conventional processes. The method is particularly useful for forming inner air electrode tubes of solid oxide fuel cells.

Borglum, Brian P. (Edgewood, PA)

2001-01-01T23:59:59.000Z

393

China Refrigerator Information Label: Specification Development and Potential Impact  

SciTech Connect

In the last five years, China's refrigerator market has grown rapidly, and now urban markets are showing signs of saturation, with ownership rates in urban households reaching 92%. Rural markets continue to grow from a much lower base. As a result of this growth, the Chinese government in 2006 decided to revise the refrigerator standards and its associated efficiency grades for the mandatory energy information label. In the Chinese standards process, the efficiency grades for the information label are tied to the minimum standards. Work on the minimum standards revision began in 2006 and continued through the first half of 2007, when the draft standard was completed under the direction of the China National Institute of Standardization (CNIS). Development of the information label grades required consideration of stakeholder input, continuity with the previous grade classification, ease of implementation, and potential impacts on the market. In this process, CLASP, with the support of METI/IEEJ, collaborated with CNIS to develop the efficiency grades, providing technical input to the process, comment and advice on particular technical issues, and evaluation of the results. After three months of effort and three drafts of the final grade specifications, this work was completed. In addition, in order to effectively evaluate the impact of the label on China's market, CLASP further provided assistance to CNIS to collect data on both the efficiency distribution and product volume distribution of refrigerators on the market. The new information label thresholds to be implemented in 2008 maintain the approach first adopted in 2005 of establishing efficiency levels relative to the minimum standard, but increased the related required efficiency levels by 20% over those established in 2003 and implemented in 2005. The focus of improvement was on the standard refrigerator/freezer (class 5), which constitutes the bulk of the Chinese market. Indeed, the new requirements to achieve grade 1 on the label are now virtually as stringent as those for US Energy Star-qualified or EU A-grade refrigerators. When the energy information label went into effect in March 2005, refrigerator manufacturers were required to display their declared level of efficiency on the label and report it to the China Energy Label Center (CELC), a newly established unit of CNIS responsible for label program management. Because of the visible nature of the label, it was found, through a METI/IEEJ-supported study, that MEPS non-compliance dropped from 4% to zero after the label became mandatory, and that the percentage of higher-grade refrigerators increased. This suggests that the label itself does have potential for shifting the market to higher-efficiency models (Lin 2007). One challenge, however, of assessing this potential impact is the lack of a comprehensive baseline of market efficiency and a program to evaluate the market impact on a yearly basis. As a result, the impact evaluation in this study draws upon the market transformation experience of the related EU energy information label, for which quantitative assessments of its market impact exist. By assuming a parallel process unfolding in China, it is possible to look at the potential impact of the label to 2020. The results of the analysis demonstrates that a robust market transformation program in China focused on the energy information label could save substantial amounts of electricity by 2020, totaling 16.4 TWh annually by that year, compared to a case in which the efficiency distribution of refrigerators was frozen at the 2007 level. Remarkably, the impact of a successful market transformation program with the label would essentially flatten the consumption of electricity for refrigerator use throughout most of the next decade, despite the expectations of continued growth in total stock by nearly 190 million units. At the end of this period, total consumption begins to rise again, as the least efficient of the units have been mostly removed from the market. Such a level of savings would reduce CO{sub

Fridley, David; Fridley, David; Zheng, Nina; Zhou, Nan; Aden, Nathaniel; Lin, Jiang; Jianhong, Cheng; Sakamoto, Tomoyuki

2008-02-01T23:59:59.000Z

394

Charcoal-methanol adsorption refrigerator powered by a compound parabolic concentrating solar collector  

SciTech Connect

A compound parabolic concentrating solar collector (CPC) of concentration ratio 3.9 and aperture area 2.0 m[sup 2] was used to power an intermittent solid adsorption refrigerator and ice maker using activated charcoal (carbon) as the adsorbing medium and methanol as the working fluid. The copper tube receiver of the CPC was packed with 2.5 kg of imported adsorbent 207E3, which was only utilized when the performance of activated charcoal (ACJ1, produced from local coconut shells) was found to be inferior to the imported adsorbent. Up to 1 kg of ice at an evaporator temperature of [minus]6[degrees]C was produced, with the net solar coefficient of performance (COP) being of the order of 0.02. Maximum receiver/adsorbent temperature recorded was 154[degrees]C on a day when the insolation was 26.8 MJ/m[sup [minus]2]. Temperatures in excess of 150[degrees]C are undesirable since they favour the conversion of methanol to dimethyl ether, a noncondensable gas which inhibits both condensation and adsorption. The major advantage of this system is its ability to produce ice even on overcast days (insolation [approximately] 10 MJ/m[sup [minus]2]).

Headley, O.StC.; Kothdiwala, A.F.; McDoom, I.A. (Univ. of the West Indies, St. Augustine (Trinidad and Tobago))

1994-08-01T23:59:59.000Z

395

Steam generator tube rupture study  

E-Print Network (OSTI)

This report describes our investigation of steam generator behavior during a postulated tube rupture accident. Our study was performed using the steam generator, thermal-hydraulic analysis code THERMIT-UTSG. The purpose ...

Free, Scott Thomas

1986-01-01T23:59:59.000Z

396

Tube-wave seismic imaging  

DOE Patents (OSTI)

The detailed analysis of cross well seismic data for a gas reservoir in Texas revealed two newly detected seismic wave effects, recorded approximately 2000 feet above the reservoir. A tube-wave (150) is initiated in a source well (110) by a source (111), travels in the source well (110), is coupled to a geological feature (140), propagates (151) through the geological feature (140), is coupled back to a tube-wave (152) at a receiver well (120), and is and received by receiver(s) (121) in either the same (110) or a different receiving well (120). The tube-wave has been shown to be extremely sensitive to changes in reservoir characteristics. Tube-waves appear to couple most effectively to reservoirs where the well casing is perforated, allowing direct fluid contact from the interior of a well case to the reservoir.

Korneev, Valeri A [LaFayette, CA

2009-05-05T23:59:59.000Z

397

Tube-wave seismic imaging  

DOE Patents (OSTI)

The detailed analysis of cross well seismic data for a gas reservoir in Texas revealed two newly detected seismic wave effects, recorded approximately 2000 feet above the reservoir. A tube-wave (150) is initiated in a source well (110) by a source (111), travels in the source well (110), is coupled to a geological feature (140), propagates (151) through the geological feature (140), is coupled back to a tube-wave (152) at a receiver well (120), and is and received by receiver(s) (121) in either the same (110) or a different receiving well (120). The tube-wave has been shown to be extremely sensitive to changes in reservoir characteristics. Tube-waves appear to couple most effectively to reservoirs where the well casing is perforated, allowing direct fluid contact from the interior of a well case to the reservoir.

Korneev, Valeri A. (Lafayette, CA); Bakulin, Andrey (Houston, TX)

2009-10-13T23:59:59.000Z

398

Heat transfer during condensation of HFC-134a and R-404A inside of a horizontal smooth and micro-fin tube  

Science Conference Proceedings (OSTI)

In recent small and medium capacity refrigeration systems, the condenser tubes are provided with micro-fins from inside. The vapour refrigerant at the compressor outlet and the condenser inlet is in superheat state. As it advances in the condenser it is in two phases and at the outlet it is in sub cooled liquid. The heat transfer coefficient (HTC) during condensation of HFC-134a and R-404A in a smooth (8.56 mm ID) and micro-fin tubes (8.96 mm ID) are experimentally investigated. Different from previous studies, the present experiments are performed for various condensing temperatures, with superheating and sub cooling and using hermetically sealed compressor. The test runs are done at average saturated condensing temperatures ranging from 35 C to 60 C. The mass fluxes are between 90 and 800 kg m{sup -2} s{sup -1}. The experimental results indicate that the average HTC increases with mass flux but decreases with increasing condensing temperature for both smooth and micro-fin tubes. The average condensation HTCs of HFC-134a and R-404A for the micro-fin tubes were 1.5-2.5 and 1.3-2 times larger than that in smooth tube respectively. The HTCs for R-404A are less than that of HFC-134a. New correlations based on the data gathered during the experimentation for predicting condensation HTCs are proposed for wide range of operating conditions. (author)

Sapali, S.N. [Govt. College of Engineering, Department of Mechanical Engineering, Shivaji Nagar, Pune, Maharashtra 411 005 (India); Patil, Pradeep A. [AISSMS College of Engineering, Pune University, Mechanical Engineering Department, Kennedy Road, Near R.T.O., Pune, Maharashtra 411 001 (India)

2010-11-15T23:59:59.000Z

399

Photomultiplier tube gain regulating system  

DOE Patents (OSTI)

This invention relates to an improved system for regulating the gain of a photomultiplier tube, and was designed for use with the photomultiplier tubes of a GeMSAEC fast analyzers. It has the following advantages over the prior system: noise is virtually eliminated; sample analysis can begin after 3 to 4 revolutions of the rotor; fluorescent and light scattering solutions can be used as a reference; and the reference solution can be in any cuvette on the rotor.

Johnson, Wayne F. (Loudon, TN)

1976-01-01T23:59:59.000Z

400

Tube wall thickness measurement apparatus  

DOE Patents (OSTI)

An apparatus for measuring the thickness of a tube's wall for the tube's entire length and circumference by determining the deviation of the tube wall thickness from the known thickness of a selected standard item. The apparatus comprises a base and a first support member having first and second ends. The first end is connected to the base and the second end is connected to a spherical element. A second support member is connected to the base and spaced apart from the first support member. A positioning element is connected to and movable relative to the second support member. An indicator is connected to the positioning element and is movable to a location proximate the spherical element. The indicator includes a contact ball for first contacting the selected standard item and holding it against the spherical element. The contact ball then contacts the tube when the tube is disposed about the spherical element. The indicator includes a dial having a rotatable needle for indicating the deviation of the tube wall thickness from the thickness of the selected standard item.

Lagasse, Paul R. (Santa Fe, NM)

1987-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Tube wall thickness measurement apparatus  

DOE Patents (OSTI)

An apparatus for measuring the thickness of a tube's wall for the tube's entire length and radius by determining the deviation of the tube wall thickness from the known thickness of a selected standard item. The apparatus comprises a base and a first support member having first and second ends. The first end is connected to the base and the second end is connected to a spherical element. A second support member is connected to the base and spaced apart from the first support member. A positioning element is connected to and movable relative to the second support member. An indicator is connected to the positioning element and is movable to a location proximate the spherical element. The indicator includes a contact ball for first contacting the selected standard item and holding it against the spherical element. The contact ball then contacts the tube when the tube is disposed about the spherical element. The indicator includes a dial having a rotatable needle for indicating the deviation of the tube wall thickness from the thickness of the selected standard item.

Lagasse, P.R.

1985-06-21T23:59:59.000Z

402

Energy and global warming impacts of next generation refrigeration and air conditioning technologies  

SciTech Connect

Significant developments have occurred in hydrofluorocarbon (HFC) and the application of ammonia and hydrocarbons as refrigerant working fluids since the original TEWI (Total Equivalent Warming Impact) report in 1991. System operating and performance data on alternative refrigerants and refrigeration technologies justify and updated evaluation of these new alternative refrigerants and competing technologies in well-characterized applications. Analytical and experimental results are used to show quantitative comparisons between HFCS, HFC blends, hydrocarbons, and ammonia, used as refrigerants. An objective evaluation is presented for commercial and near commercial non-CFC refrigerants/blowing agents and alternative refrigeration technologies. This information is needed for objective and quantitative decisions on policies addressing greenhouse gas emissions from refrigeration and air conditioning equipment. The evaluation assesses the energy use and global warming impacts of refrigeration and air conditioning technologies that could be commercialized during the phase out of HCFCS. Quantitative comparison TEWI for two application areas are presented. Opportunities for significant reductions in TEWI are seen with currently known refrigerants through improved maintenance and servicing practices and improved product designs.

Sand, J.R.; Fischer, S.K.; Baxter, V.D.

1996-10-01T23:59:59.000Z

403

Guidelines on Airflow and Refrigerant Charge Verification and Diagnostics  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

GUIDELINES ON AIRFLOW AND GUIDELINES ON AIRFLOW AND REFRIGERANT CHARGE VERIFICATION AND DIAGNOSTICS Alliance for Residential Building Innovation David Springer, Davis Energy Group Context  Airflow and refrigerant charge defects in existing air conditioning systems are well documented  Failure to address these problems represents a missed opportunity for home performance contractors  To ensure cost-effective solutions, a systematic approach is needed to quickly and accurately diagnose and resolve problems  Target:  Home performance contractors  HVAC contractors & technicians The Impact of Defects Non-TXV TXV 15% duct leakage 1 -18.10% 23% low airflow -4.70% 50% condenser coil blockage -5.80% 50% evaporator coil blockage 2 -4.60% -4.20% 20% overcharge -3.50% -7.90%

404

Cryogenics for superconductors: Refrigeration, delivery, and preservation of the cold  

SciTech Connect

Applications in superconductivity have become widespread, enabled by advancements in cryogenic engineering. In this paper, the history of cryogenic refrigeration, its delivery, its preservation and the important scientific and engineering advancements in these areas in the last 100 years will be reviewed, beginning with small laboratory dewars to very large scale systems. The key technological advancements in these areas that enabled the development of superconducting applications at temperatures from 4 to 77 K are identified. Included are advancements in the components used up to the present state-of-the-art in refrigeration systems design. Viewpoints as both an equipment supplier and the end-user with regard to the equipment design and operations will be presented. Some of the present and future challenges in these areas will be outlined. Most of the materials in this paper are a collection of the historical materials applicable to these areas of interest.

Venkatarao Ganni, James Fesmire

2012-06-01T23:59:59.000Z

405

Magnetic Refrigeration Technology for High Efficiency Air Conditioning  

SciTech Connect

Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

Boeder, A; Zimm, C

2006-09-30T23:59:59.000Z

406

Waste heat driven absorption refrigeration process and system  

DOE Patents (OSTI)

Absorption cycle refrigeration processes and systems are provided which are driven by the sensible waste heat available from industrial processes and other sources. Systems are disclosed which provide a chilled water output which can be used for comfort conditioning or the like which utilize heat from sensible waste heat sources at temperatures of less than 170.degree. F. Countercurrent flow equipment is also provided to increase the efficiency of the systems and increase the utilization of available heat.

Wilkinson, William H. (Columbus, OH)

1982-01-01T23:59:59.000Z

407

The characterization of flow regimes with power spectral density distributions of pressure fluctuations during condensation in smooth and micro-fin tubes  

Science Conference Proceedings (OSTI)

This paper presents an objective predictor of the prevailing flow regime during refrigerant condensation inside smooth-, micro-fin and herringbone tubes. The power spectral density (PSD) distribution of the fluctuating condensing pressure signal was used to predict the prevailing flow regime, as opposed to the traditional (and subjective) use of visual-only methods, and/or smooth-tube flow regime maps. The prevailing flow regime was observed by using digital cameras and was validated with the use of the conventional smooth-tube flow regime transition criteria, Froude rate criteria, as well as a new flow regime map that was developed for micro-fin tube condensation. Experimental work was conducted for condensing R-22, R-407C, and R-134a at an average saturation temperature of 40{sup o}C with mass fluxes ranging from 300 to 800kg/m{sup 2}s, and with vapour qualities ranging from 0.85-0.95 at condenser inlet to 0.05-0.15 at condenser outlet. Tests were conducted with one smooth-tube condenser and three micro-fin tube condensers (with helix angles of 10{sup o}, 18{sup o}, and 37{sup o}, respectively). It is shown that the micro-fin tubes cause a delay in the transition from annular to intermittent flow by at least 19% (compared to the smooth tube), thus significantly contributing to the enhancement of heat transfer. (author)

Liebenberg, Leon; Meyer, Josua P. [Department of Mechanical and Aeronautical Engineering, University of Pretoria, Pretoria 0002 (South Africa)

2006-11-15T23:59:59.000Z

408

New waste-heat refrigeration unit cuts flaring, reduces pollution  

Science Conference Proceedings (OSTI)

Planetec Utility Services Co. Inc. and Energy Concepts Co. (ECC), with the help of the US Department of Energy (DOE), developed and commissioned a unique waste-heat powered LPG recovery plant in August 1997 at the 30,000 b/d Denver refinery, operated by Ultramar Diamond Shamrock (UDS). This new environmentally friendly technology reduces flare emissions and the loss of salable liquid-petroleum products to the fuel-gas system. The waste heat ammonia absorption refrigeration plant (Whaarp) is the first technology of its kind to use low-temperature waste heat (295 F) to achieve sub-zero refrigeration temperatures ({minus}40 F) with the capability of dual temperature loads in a refinery setting. The ammonia absorption refrigeration is applied to the refinery`s fuel-gas makeup streams to condense over 180 b/d of salable liquid hydrocarbon products. The recovered liquid, about 64,000 bbl/year of LPG and gasoline, increases annual refinery profits by nearly $1 million, while substantially reducing air pollution emissions from the refinery`s flare.

Brant, B.; Brueske, S. [Planetec Utility Services Co., Inc., Evergreen, CO (United States); Erickson, D.; Papar, R. [Energy Concepts Co., Annapolis, MD (United States)

1998-05-18T23:59:59.000Z

409

The Proof is in the Pudding: How Refrigerator Standards Have Saved  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Proof is in the Pudding: How Refrigerator Standards Have Saved The Proof is in the Pudding: How Refrigerator Standards Have Saved Consumers $Billions The Proof is in the Pudding: How Refrigerator Standards Have Saved Consumers $Billions July 11, 2011 - 12:33pm Addthis Today’s refrigerators have been designed to save energy and money without detriment to capacity, functionality, or extra features. | Image source: Building Technologies Program Today's refrigerators have been designed to save energy and money without detriment to capacity, functionality, or extra features. | Image source: Building Technologies Program Roland Risser Roland Risser Program Director, Building Technologies Office What does this mean for me? Today's refrigerators use only about 25 percent of the energy compared to models built in 1975. They've also increased in size by almost 20 percent, with lots of

410

The Proof is in the Pudding: How Refrigerator Standards Have Saved  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Proof is in the Pudding: How Refrigerator Standards Have Saved The Proof is in the Pudding: How Refrigerator Standards Have Saved Consumers $Billions The Proof is in the Pudding: How Refrigerator Standards Have Saved Consumers $Billions July 11, 2011 - 12:33pm Addthis Today’s refrigerators have been designed to save energy and money without detriment to capacity, functionality, or extra features. | Image source: Building Technologies Program Today's refrigerators have been designed to save energy and money without detriment to capacity, functionality, or extra features. | Image source: Building Technologies Program Roland Risser Roland Risser Program Director, Building Technologies Office What does this mean for me? Today's refrigerators use only about 25 percent of the energy compared to models built in 1975. They've also increased in size by almost 20 percent, with lots of

411

Compatibility of refrigerants and lubricants with elastomers. Quarterly report, 1 April 1992--30 June 1992  

Science Conference Proceedings (OSTI)

Information contained in this reporters designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. Swell measurements have been made on approximately 50% of the proposed elastomers (94 total)in both the lubricant (7 total) and refrigerant (10 total) materials. Swell behavior in the these fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1992-07-01T23:59:59.000Z

412

Method of removing an immiscible lubricant from a refrigeration system and apparatus for same  

DOE Patents (OSTI)

A method is described for separating an immiscible lubricant from a liquid refrigerant in a refrigerating system including a compressor, a condenser, an expansion device and an evaporator, wherein the expansion device is connected to the condenser by a liquid refrigerant flow line for liquid refrigerant and immiscible lubricant. The method comprising slowing the rate of flow of the liquid refrigerant and immiscible lubricant between the condenser and the expansion device such that the liquid refrigerant and the immiscible lubricant separate based upon differences in density. The method also comprises collecting the separated immiscible lubricant in a collection chamber in fluid communication with the separated immiscible lubricant. Apparatus for performing the method is also disclosed. 3 figs.

Spauschus, H.O.; Starr, T.L.

1999-03-30T23:59:59.000Z

413

A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus  

SciTech Connect

This paper provides an overview of the variable refrigerant flow heat pump computer model included with the Department of Energy's EnergyPlusTM whole-building energy simulation software. The mathematical model for a variable refrigerant flow heat pump operating in cooling or heating mode, and a detailed model for the variable refrigerant flow direct-expansion (DX) cooling coil are described in detail.

Raustad, Richard A. [Florida Solar Energy Center

2013-01-01T23:59:59.000Z

414

Comparing Variable Refrigerant Flow to Traditional Heating and Cooling Technologies: Assessing VRF Performance in Mobile, Alabama  

Science Conference Proceedings (OSTI)

In America, most conditioned air is delivered by ductwork, which is often made of sheet metal covered in insulation and installed during construction. However, in Japan and Europe, because the office buildings often pre-date the invention of air conditioning, it is easier and more common for refrigerant pipes to run to wall- or ceiling-mounted heat exchangers. Using refrigerant pipes instead of ducting can eliminate duct loss and offer more precise control. Are Variable Refrigerant Flow (VRF) ...

2013-09-04T23:59:59.000Z

415

Performance Assessment of a Variable Refrigerant Flow Heat Pump Air Conditioning System  

Science Conference Proceedings (OSTI)

Variable refrigerant flow (VRF) technology uses smart integrated controls, variable speed drives, and refrigerant piping to provide energy efficiency, flexible operation, ease of installation, low noise, zone control, and comfort through all-electric technology. This report describes and documents the construction, performance, and application of a heat pump air conditioning system that uses VRF technology8212the Daikin VRV system. This variable refrigerant volume (VRV) system is manufactured by Daikin I...

2008-12-17T23:59:59.000Z

416

Table B36. Refrigeration Equipment, Number of Buildings and Floorspace, 1999  

U.S. Energy Information Administration (EIA) Indexed Site

6. Refrigeration Equipment, Number of Buildings and Floorspace, 1999" 6. Refrigeration Equipment, Number of Buildings and Floorspace, 1999" ,"Number of Buildings (thousand)",,,,,"Total Floorspace (million square feet)" ,"All Buildings","All Buildings with Refrigeration Equipment","Type of Equipment (more than one may apply)",,,"All Buildings","All Buildings with Refrigeration Equipment","Type of Equipment (more than one may apply)" ,,,"Walk-In","Open Cases or Cabinets","Closed Cases or Cabinets",,,"Walk-In","Open Cases or Cabinets","Closed Cases or Cabinets" "All Buildings ................",4657,950,658,255,719,67338,25652,19713,8808,19938 "Building Floorspace"

417

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network (OSTI)

comparison of VAV and VRF air conditioning systems in anThe variable refrigerant flow (VRF) and ground source heatthe energy efficiency of VRF systems compared with GSHP

Hong, Tainzhen

2010-01-01T23:59:59.000Z

418

Opportunities for Energy Efficiency and Automated Demand Response in Industrial Refrigerated Warehouses in California  

E-Print Network (OSTI)

Southern California Edison (2007). DR Strategies for Coldof Southern California Edison Refrigerated Warehouses byTable 5. Southern California Edison Commercial Cold Storage

Lekov, Alex

2009-01-01T23:59:59.000Z

419

Superheat control for air conditioning and refrigeration systems: Simulation and experiments.  

E-Print Network (OSTI)

??Ever since the invention of air conditioning and refrigeration in the late nineteenth century, there has been tremendous interest in increasing system efficiency to reduce… (more)

Otten, Richard J.

2010-01-01T23:59:59.000Z

420

Solar refrigeration in rural West Bengal: Design of a product service system.  

E-Print Network (OSTI)

??Solarbear is a refrigerator that cools with the heat of the sun only. This technology, more formally known as solar powered adsorption cooling, has been… (more)

Van Genuchten, R.P.

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Electric, Gas, Water, Heating, Refrigeration, and Street Railways Facilities and Service (South Dakota)  

Energy.gov (U.S. Department of Energy (DOE))

This legislation contains provisions for facilities and service related to electricity, natural gas, water, heating, refrigeration, and street railways. The chapter addresses the construction and...

422

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network (OSTI)

refrigerator operate with propane as well as electricity? [freezer operate with propane as well as electricity? [cooler operate with propane as well as electricity? [

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

423

Core-tube data logger  

DOE Green Energy (OSTI)

Wireline core drilling, increasingly used for geothermal exploration, employs a core-tube to capture a rock core sample during drilling. Three types of core-tube data loggers (CTDL) have been built and tested to date by Sandia national Laboratories. They are: (1) temperature-only logger, (2) temperature/inclinometer logger and (3) heat-shielded temperature/inclinometer logger. All were tested during core drilling operations using standard wireline diamond core drilling equipment. While these tools are designed for core-tube deployment, the tool lends itself to be adapted to other drilling modes and equipment. Topics covered in this paper include: (1) description on how the CTDLs are implemented, (2) the components of the system, (3) the type of data one can expect from this type of tool, (4) lessons learned, (5) comparison to its counterpart and (6) future work.

Henfling, J.A.; Normann, R.A.; Knudsen, S.; Drumheller, D.

1997-01-01T23:59:59.000Z

424

Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line  

DOE Patents (OSTI)

The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.

Gaul, Christopher J. (Thornton, CO)

2001-01-01T23:59:59.000Z

425

Overview of CFC replacement issues for household refrigeration  

Science Conference Proceedings (OSTI)

In 1974, the famous ozone depletion theory of Rowland and Molina claimed that chlorofluorocarbons (CFCs) diffuse into the stratosphere where they are broken down by photolysis to release chlorine atoms that catalytically destroy ozone. Although the understanding of the science is still imperfect, there is little doubt that CFCs play a major role in the Antarctic ozone hole phenomenon and the decline in ozone observed in the rest of the world. Another issue that has become increasingly important is the potential of CFCs to change the earth's temperature and to modify the climate. While the main impact in global warming is made by increased concentrations of carbon dioxide, CFCs and other trace gases also contribute to this effect. In an effort to respond to the global environmental threat, a CFC protocol was adopted during a diplomatic conference in Montreal. This document, known as the Montreal Protocol, was ratified in 1988 and put into effect on January 1, 1989. In accordance with Article 6 of the Montreal Protocol, the countries that signed the agreement shall periodically assess the control measures provided for in the Protocol. As part of that assessment process, household refrigeration was investigated to determine the status of CFC-12 replacements. The conclusion was that much progress has been made towards finding a suitable replacement. Compressors designed for HFC-134a have efficiencies comparable to those for CFC-12 and acceptable reliability tests have been obtained with ester lubricants. In addition, other replacements such as R-152a and refrigerant mixtures exist, but will require more study. Cycle options, such as the Stirling cycle, may be viable, but are further out in the future. The impact of new refrigerants is expected to result in elimination of CFC-12 consumption in developed countries by 1997 and in developing countries by 2005.

Vineyard, E.A. (Oak Ridge National Lab., TN (United States)); Roke, L. (Fisher and Paykel, Auckland (New Zealand)); Hallett, F. (Frigidaire, Washington, DC (United States))

1991-01-01T23:59:59.000Z

426

Overview of CFC replacement issues for household refrigeration  

Science Conference Proceedings (OSTI)

In 1974, the famous ozone depletion theory of Rowland and Molina claimed that chlorofluorocarbons (CFCs) diffuse into the stratosphere where they are broken down by photolysis to release chlorine atoms that catalytically destroy ozone. Although the understanding of the science is still imperfect, there is little doubt that CFCs play a major role in the Antarctic ozone hole phenomenon and the decline in ozone observed in the rest of the world. Another issue that has become increasingly important is the potential of CFCs to change the earth`s temperature and to modify the climate. While the main impact in global warming is made by increased concentrations of carbon dioxide, CFCs and other trace gases also contribute to this effect. In an effort to respond to the global environmental threat, a CFC protocol was adopted during a diplomatic conference in Montreal. This document, known as the Montreal Protocol, was ratified in 1988 and put into effect on January 1, 1989. In accordance with Article 6 of the Montreal Protocol, the countries that signed the agreement shall periodically assess the control measures provided for in the Protocol. As part of that assessment process, household refrigeration was investigated to determine the status of CFC-12 replacements. The conclusion was that much progress has been made towards finding a suitable replacement. Compressors designed for HFC-134a have efficiencies comparable to those for CFC-12 and acceptable reliability tests have been obtained with ester lubricants. In addition, other replacements such as R-152a and refrigerant mixtures exist, but will require more study. Cycle options, such as the Stirling cycle, may be viable, but are further out in the future. The impact of new refrigerants is expected to result in elimination of CFC-12 consumption in developed countries by 1997 and in developing countries by 2005.

Vineyard, E.A. [Oak Ridge National Lab., TN (United States); Roke, L. [Fisher and Paykel, Auckland (New Zealand); Hallett, F. [Frigidaire, Washington, DC (United States)

1991-12-31T23:59:59.000Z

427

How small can thermal machines be? The smallest possible refrigerator  

E-Print Network (OSTI)

We investigate the fundamental dimensional limits to thermodynamic machines. In particular we show that it is possible to construct self-contained refrigerators (i.e. not requiring external sources of work) consisting of only a small number of qubits and/or qutrits. We present three different models, consisting of two qubits, a qubit and a qutrit with nearest-neighbour interactions, and a single qutrit respectively. We then investigate fundamental limits to their performance; in particular we show that it is possible to cool towards absolute zero.

Noah Linden; Sandu Popescu; Paul Skrzypczyk

2009-08-14T23:59:59.000Z

428

Combustion Gas Turbine Power Enhancement by Refrigeration of Inlet Air  

E-Print Network (OSTI)

Combustion gas turbines have gained widespread acceptance for mechanical drive and power generation applications. One key drawback of a combustion turbine is that its specific output and thermal efficiency vary quite significantly with variations in the ambient temperature. On hot days, a machine may experience considerable difficulty in meeting its power demand. One concept that has not received much attention is the cooling down of compressor inlet air. This paper will examine the theoretical and practical implications of concept such as evaporative cooling, intercooling, expansion cooling and compression and absorption refrigeration.

Meher-Homji, C. B.; Mani, G.

1983-01-01T23:59:59.000Z

429

China Refrigerator Information Label: Specification Development and Potential Impact  

SciTech Connect

In the last five years, China's refrigerator market has grown rapidly, and now urban markets are showing signs of saturation, with ownership rates in urban households reaching 92%. Rural markets continue to grow from a much lower base. As a result of this growth, the Chinese government in 2006 decided to revise the refrigerator standards and its associated efficiency grades for the mandatory energy information label. In the Chinese standards process, the efficiency grades for the information label are tied to the minimum standards. Work on the minimum standards revision began in 2006 and continued through the first half of 2007, when the draft standard was completed under the direction of the China National Institute of Standardization (CNIS). Development of the information label grades required consideration of stakeholder input, continuity with the previous grade classification, ease of implementation, and potential impacts on the market. In this process, CLASP, with the support of METI/IEEJ, collaborated with CNIS to develop the efficiency grades, providing technical input to the process, comment and advice on particular technical issues, and evaluation of the results. After three months of effort and three drafts of the final grade specifications, this work was completed. In addition, in order to effectively evaluate the impact of the label on China's market, CLASP further provided assistance to CNIS to collect data on both the efficiency distribution and product volume distribution of refrigerators on the market. The new information label thresholds to be implemented in 2008 maintain the approach first adopted in 2005 of establishing efficiency levels relative to the minimum standard, but increased the related required efficiency levels by 20% over those established in 2003 and implemented in 2005. The focus of improvement was on the standard refrigerator/freezer (class 5), which constitutes the bulk of the Chinese market. Indeed, the new requirements to achieve grade 1 on the label are now virtually as stringent as those for US Energy Star-qualified or EU A-grade refrigerators. When the energy information label went into effect in March 2005, refrigerator manufacturers were required to display their declared level of efficiency on the label and report it to the China Energy Label Center (CELC), a newly established unit of CNIS responsible for label program management. Because of the visible nature of the label, it was found, through a METI/IEEJ-supported study, that MEPS non-compliance dropped from 4% to zero after the label became mandatory, and that the percentage of higher-grade refrigerators increased. This suggests that the label itself does have potential for shifting the market to higher-efficiency models (Lin 2007). One challenge, however, of assessing this potential impact is the lack of a comprehensive baseline of market efficiency and a program to evaluate the market impact on a yearly basis. As a result, the impact evaluation in this study draws upon the market transformation experience of the related EU energy information label, for which quantitative assessments of its market impact exist. By assuming a parallel process unfolding in China, it is possible to look at the potential impact of the label to 2020. The results of the analysis demonstrates that a robust market transformation program in China focused on the energy information label could save substantial amounts of electricity by 2020, totaling 16.4 TWh annually by that year, compared to a case in which the efficiency distribution of refrigerators was frozen at the 2007 level. Remarkably, the impact of a successful market transformation program with the label would essentially flatten the consumption of electricity for refrigerator use throughout most of the next decade, despite the expectations of continued growth in total stock by nearly 190 million units. At the end of this period, total consumption begins to rise again, as the least efficient of the units have been mostly removed from the market. Such a level of savings would redu

Fridley, David; Fridley, David; Zheng, Nina; Zhou, Nan; Aden, Nathaniel; Lin, Jiang; Jianhong, Cheng; Sakamoto, Tomoyuki

2008-02-01T23:59:59.000Z

430

Cooling an electron gas using quantum dot based electronic refrigeration  

E-Print Network (OSTI)

of the QDR experiment have been published in: • J. R. Prance, C. G. Smith, J. P. Griffiths, S. J. Chorley, D. Anderson, G. A. C. Jones, I. Farrer, and D. A. Ritchie, Electronic refrigeration of a two- dimensional electron gas, Phys. Rev. Lett. 102(14), 146602... for the electrochemical potential of the dot: we define µN :i,j = Ui(N)?Uj(N ? 1), where Ui(N) is the energy of the dot holding N electrons with the last electron in the ith excited state. For example, the previous definition of µN is equivalent to µN :0,0. (The...

Prance, Jonathan Robert

2009-10-13T23:59:59.000Z

431

Impact of the Variable Refrigerant Volume Air Conditioning System on Building Energy Efficiency  

E-Print Network (OSTI)

The application of the variable refrigerant volume multi-zone air conditioning systems has met with mixed results since the publication of the Design Standard for Energy Efficiency of Public Buildings. This paper analyzes the characteristics of the variable refrigerant volume multi-zone air conditioning system, and discusses the advantages of its application.

Zhu, H.

2006-01-01T23:59:59.000Z

432

CORRELATING EVAPORATION HEAT TRANSFER COEFFICIENT OF REFRIGERANT R-134a IN A PLATE HEAT EXCHANGER  

E-Print Network (OSTI)

1 CORRELATING EVAPORATION HEAT TRANSFER COEFFICIENT OF REFRIGERANT R-134a IN A PLATE HEAT EXCHANGER for evaporation heat transfer coefficient of refrigerant R-134a flowing in a plate heat exchanger. Correlation heat exchanger are found to result in large discrepancies with their own experimental data

Kandlikar, Satish

433

Determination of thermodynamic properties of an alternative refrigerant (R407c) using artificial neural network  

Science Conference Proceedings (OSTI)

Thermodynamic analysis of the refrigeration systems is too complex because of thermodynamic properties equations of working fluids, involving the solution of complex differential equations. To simplify this complex process, this paper proposes a new ... Keywords: Artificial neural networks, Ozone safe refrigerant, R407c, Thermodynamic properties

Adnan Sözen; Erol Arcaklio?lu; Tayfun Menlik; Mehmet Özalp

2009-04-01T23:59:59.000Z

434

Chapter 4: Refrigeration Process Control: Simulation Model 64 44.. RREEFFRRIIGGEERRAATTIIOONN PPRROOCCEESSSS  

E-Print Network (OSTI)

Chapter 4: Refrigeration Process Control: Simulation Model 64 44.. RREEFFRRIIGGEERRAATTIIOONN of the simulation model for the two-stage refrigeration system is presented. The model is based on the mathematical equations and transfer functions. Typical application areas are control system design, chemical process

Skogestad, Sigurd

435

PROCESS DESIGN AND CONTROL Steady-State Operational Degrees of Freedom with Application to Refrigeration  

E-Print Network (OSTI)

PROCESS DESIGN AND CONTROL Steady-State Operational Degrees of Freedom with Application to Refrigeration Cycles Jørgen Bauck Jensen and Sigurd Skogestad* Department of Chemical Engineering, Norwegian Uni of the circulating refrigerant are also discussed. Two liquified natural gas (LNG) processes of current interest

Skogestad, Sigurd

436

FLOATING PRESSURE CONVERSION AND EQUIPMENT UPGRADES OF TWO 3.5KW, 20K, HELIUM REFRIGERATORS  

SciTech Connect

Two helium refrigerators, each rated for 3.5 KW at 20 K, are used at NASA's Johnson Space Center (JSC) in Building No. 32 to provide cryogenic-pumping within two large thermal-vacuum chambers. These refrigerators were originally commissioned in 1996. New changes to the controls of these refrigerators were recently completed. This paper describes some of the control issues that necessitated the controls change-over. It will describe the modifications and the new process control which allows the refrigerators to take advantage of the Ganni Cycle “floating pressure” control technology. The controls philosophy change-over to the floating pressure control technology was the first application on a helium gas refrigeration system. Previous implementations of the floating pressure technology have been on 4 K liquefaction and refrigeration systems, which have stored liquid helium volumes that have level indications used for varying the pressure levels (charge) in the system for capacity modulation. The upgrades have greatly improved the performance, stability, and efficiency of these two refrigerators. The upgrades have also given the operators more information and details about the operational status of the main components (compressors, expanders etc.) of the refrigerators at all operating conditions (i.e. at various loads in the vacuum chambers). The performance data of the two systems, pre and post upgrading are presented.

J. Homan, V. Ganni, A. Sidi-Yekhlef, J. Creel, R. Norton, R. Linza, G. Vargas, J. Lauterbach, J. Urbin, D. Howe

2010-04-01T23:59:59.000Z

437

Analysis of a commercial absorption-refrigeration water-ammonia (ARWA) cycle using Aspen Plus simulator  

Science Conference Proceedings (OSTI)

The Robur absorption-refrigeration-water-ammonia (ARWA) cycle is analyzed using Aspen Plus flowsheet simulator. The results are compared with experimental and some manufacturer data reported in the open literature. Among performance parameters analyzed ... Keywords: Aspen, COP, absorption, ammonia, refrigeration, simulation, water

N. A. Darwish; S. H. Al-Hashimi; A. S. Al-Mansoori

2008-08-01T23:59:59.000Z

438

Exergetic analyse for the cooling systems with R-407 refrigerant for application in nuclear plants  

Science Conference Proceedings (OSTI)

The experimental Pilot plant for tritium and deuterium separation, part of National Research and Development Institute for Cryogenics and Isotopic Technologies - ICSI Rm. Valcea, as principal target have to establish the technology of the water-hydrogen ... Keywords: R407 refrigerant, irreversibility, nuclear plants, refrigeration efficiency

Sorin Gherghinescu

2010-06-01T23:59:59.000Z

439

Unique method for liquid nitrogen precooling of a plate fin heat exchanger in a helium refrigeration cycle  

E-Print Network (OSTI)

Unique method for liquid nitrogen precooling of a plate fin heat exchanger in a helium refrigeration cycle

Weber, T B; Howell, G; Racine, M; Weisend, J G

2004-01-01T23:59:59.000Z

440

Ceramic vacuum tubes for geothermal well logging  

DOE Green Energy (OSTI)

Useful design data acquired in the evaluation of ceramic vacuum tubes for the development of a 500/sup 0/C instrumentation amplifier are presented. The general requirements for ceramic vacuum tubes are discussed for application to the development of high temperature well logs. Commercially available tubes are described and future contract activities that specifically relate to ceramic vacuum tubes are detailed. Supplemental data are presented in the appendix.

Kelly, R.D.

1977-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

NIST Launches YouTube Channel  

Science Conference Proceedings (OSTI)

... The Department of Commerce negotiated a contract with Google that allows its agencies to establish YouTube channels. ...

2011-04-06T23:59:59.000Z

442

Compatibility of refrigerants and lubricants with elastomers. Quarterly report, 1 July 1992--30 September 1992  

SciTech Connect

Information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on the availability of additional quantities of R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1992-10-01T23:59:59.000Z

443

Compatibility of refrigerants and lubricants with elastomers. Quarterly report, 1 October 1992--30 December 1992  

Science Conference Proceedings (OSTI)

The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on availability of additional R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1993-01-01T23:59:59.000Z

444

COFELY Refrigeration | Rdiger Roth | European Heat Pump Summit 2013 CopyrightCOFELYDeutuschlandGmbH2009.AlleRechtevorbehalten.  

E-Print Network (OSTI)

©COFELYDeutuschlandGmbH2009.AlleRechtevorbehalten. Industrial Design #12;COFELY Refrigeration | Rüdiger Roth | European HeatCOFELY Refrigeration | Rüdiger Roth | European Heat Pump Summit 2013 Seite 1 Copyright©COFELYDeutuschlandGmbH2009.AlleRechtevorbehalten. #12;COFELY Refrigeration | Rüdiger Roth | European Heat Pump Summit 2013

Oak Ridge National Laboratory

445

Manual tube-to-tubesheet welding torch  

DOE Patents (OSTI)

A welding torch made of a high temperature plastic which fits over a tube intermediate the ends thereof for welding the juncture between the tube and the back side of a tube plate and has a ballooned end in which an electrode, filler wire guide, fiber optic bundle, and blanketing gas duct are disposed.

Kiefer, Joseph H. (Tampa, FL); Smith, Danny J. (Tampa, FL)

1982-01-01T23:59:59.000Z

446

Spring/dimple instrument tube restraint  

DOE Patents (OSTI)

A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs. 7 figures.

DeMario, E.E.; Lawson, C.N.

1993-11-23T23:59:59.000Z

447

Spring/dimple instrument tube restraint  

DOE Patents (OSTI)

A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs.

DeMario, Edmund E. (Columbia, SC); Lawson, Charles N. (Columbia, SC)

1993-01-01T23:59:59.000Z

448

Heat exchanger with a removable tube section  

DOE Patents (OSTI)

A heat exchanger is described in which the tube sheet is secured against primary liquid pressure, but which allows for easy removal of the tube section. The tube section is supported by a flange which is secured by a number of shear blocks, each of which extends into a slot which is immovable with respect to the outer shell of the heat exchanger. (auth)

Wolowodiuk, W.; Anelli, J.

1975-07-29T23:59:59.000Z

449

REFRIGERANT-BASED PROPULSION SYSTEM FOR SMALL SPACECRAFT  

E-Print Network (OSTI)

The MR SAT spacecraft under development at UMR requires a propulsion system that can be utilized to perform orbital maneuvers and three-axis attitude control to complete its mission objective of conducting spacecraft formation flight. This thesis documents the research, analysis design and development of the cold gas propulsion system that was integrated in the MR SAT spacecraft. The basis of design and safety requirements stemmed from the AFRL University Nanosat Program competition, in which the UMR SAT project placed third out of eleven schools from across the nation. The MR SAT propulsion system was a primary feature as it implements a refrigerant (R-134a) propellant that has never been flown in space. As detailed in this thesis, through engineering modeling and laboratory testing R-134a is demonstrated to be a feasible propellant for small spacecraft. As the R-134a is stored as a saturated liquid in the tank, it was necessary to analyze the thermodynamic properties of the refrigerant and investigate phase changes for its use as a propellant. Also documented is the hardware selected and the integration into the MR SAT spacecraft, along with the laboratory testing

Carl Reiner Seubert; Dr. Kelly; O. Homan

2007-01-01T23:59:59.000Z

450

Waste Heat Powered Ammonia Absorption Refrigeration Unit for LPG Recovery  

SciTech Connect

An emerging DOE-sponsored technology has been deployed. The technology recovers light ends from a catalytic reformer plant using waste heat powered ammonia absorption refrigeration. It is deployed at the 17,000 bpd Bloomfield, New Mexico refinery of Western Refining Company. The technology recovers approximately 50,000 barrels per year of liquefied petroleum gas that was formerly being flared. The elimination of the flare also reduces CO2 emissions by 17,000 tons per year, plus tons per year reductions in NOx, CO, and VOCs. The waste heat is supplied directly to the absorption unit from the Unifiner effluent. The added cooling of that stream relieves a bottleneck formerly present due to restricted availability of cooling water. The 350oF Unifiner effluent is cooled to 260oF. The catalytic reformer vent gas is directly chilled to minus 25oF, and the FCC column overhead reflux is chilled by 25oF glycol. Notwithstanding a substantial cost overrun and schedule slippage, this project can now be considered a success: it is both profitable and highly beneficial to the environment. The capabilities of directly-integrated waste-heat powered ammonia absorption refrigeration and their benefits to the refining industry have been demonstrated.

Donald C, Energy Concepts Co.; Lauber, Eric, Western Refining Co.

2008-06-20T23:59:59.000Z

451

ESD hazards associated with CO{sub 2} refrigeration  

SciTech Connect

Apparent malfunctions of two Trajectory Sensing Signal Generators (TSSGs) were observed during B61-3/4/10 trajectory arming tests at the Pantex Weapons Evaluation Test Laboratory (WETL). On two subsequent occasions, the TSSG used in the B83 bomb developed single-channel failures during tests at WETL. It was concluded that the failures were related to the electrostatic discharge (ESD) hazard associated with the use of a Thermotron{reg_sign} liquid carbon dioxide (CO{sub 2}) refrigeration system. It was demonstrated that during temperature conditioning, the case of the TSSG can acquire a substantial electrostatic charge as a result of triboelectric processes. A series of tests was performed to identify the charging mechanisms associated with liquid CO{sub 2} refrigeration systems and a quantitative assessment of the ESD hazard was made. The conclusions and recommendations derived in these tests were summarized in a Significant Finding Investigations Closeout. The purpose of this report is to provide formal documentation for, and elaboration on, issues addressed in the Findings.

Jones, R.D.; Chen, K.C.; Holmes, S.W.

1994-08-01T23:59:59.000Z

452

Heat pump/refrigerator using liquid working fluid  

DOE Patents (OSTI)

A heat transfer device is described that can be operated as a heat pump or refrigerator, which utilizes a working fluid that is continuously in a liquid state and which has a high temperature-coefficient of expansion near room temperature, to provide a compact and high efficiency heat transfer device for relatively small temperature differences as are encountered in heating or cooling rooms or the like. The heat transfer device includes a pair of heat exchangers that may be coupled respectively to the outdoor and indoor environments, a regenerator connecting the two heat exchangers, a displacer that can move the liquid working fluid through the heat exchangers via the regenerator, and a means for alternately increasing and decreasing the pressure of the working fluid. The liquid working fluid enables efficient heat transfer in a compact unit, and leads to an explosion-proof smooth and quiet machine characteristic of hydraulics. The device enables efficient heat transfer as the indoor-outdoor temperature difference approaches zero, and enables simple conversion from heat pumping to refrigeration as by merely reversing the direction of a motor that powers the device.

Wheatley, John C. (Del Mar, CA); Paulson, Douglas N. (Del Mar, CA); Allen, Paul C. (Solana Beach, CA); Knight, William R. (Corvallis, OR); Warkentin, Paul A. (San Diego, CA)

1982-01-01T23:59:59.000Z

453

Steam Generator Tube-Plugging and Tube-Sleeving Criteria: Assessment of Current Practices  

Science Conference Proceedings (OSTI)

This report presents a survey of current utility practices regarding steam generator tube plugging and tube sleeving. It also describes an analytic and experimental evaluation of mechanical strain as a parameter for use in tube-plugging and tube-sleeving criteria.

1983-03-01T23:59:59.000Z

454

Ionization tube simmer current circuit  

DOE Patents (OSTI)

A highly efficient flash lamp simmer current circuit utilizes a fifty percent duty cycle square wave pulse generator to pass a current over a current limiting inductor to a full wave rectifier. The DC output of the rectifier is then passed over a voltage smoothing capacitor through a reverse current blocking diode to a flash lamp tube to sustain ionization in the tube between discharges via a small simmer current. An alternate embodiment of the circuit combines the pulse generator and inductor in the form of an FET off line square wave generator with an impedance limited step up output transformer which is then applied to the full wave rectifier as before to yield a similar simmer current.

Steinkraus, Jr., Robert F. (Livermore, CA)

1994-01-01T23:59:59.000Z

455

HIGH CURRENT COAXIAL PHOTOMULTIPLIER TUBE  

DOE Patents (OSTI)

A medium-gain photomultiplier tube having high current output, fast rise- time, and matched output impedance was developed. The photomultiplier tube comprises an elongated cylindrical envelope, a cylindrical anode supported at the axis of the envelope, a plurality of elongated spaced opaque areas on the envelope, and a plurality of light admitting windows. A photo-cathode is supported adjacent to each of the windows, and a plurality of secondary emissive dynodes are arranged in two types of radial arrays which are alternately positioned to fill the annular space between the anode and the envelope. The dynodes are in an array being radially staggered with respect to the dynodes in the adjacent array, the dynodes each having a portion arranged at an angle with respect to the electron path, such that electrons emitted by each cathode undergo multiplication upon impingement on a dynode and redirected flight to the next adjacent dynode.

Glass, N.W.

1960-01-19T23:59:59.000Z

456

Ionization tube simmer current circuit  

DOE Patents (OSTI)

A highly efficient flash lamp simmer current circuit utilizes a fifty percent duty cycle square wave pulse generator to pass a current over a current limiting inductor to a full wave rectifier. The DC output of the rectifier is then passed over a voltage smoothing capacitor through a reverse current blocking diode to a flash lamp tube to sustain ionization in the tube between discharges via a small simmer current. An alternate embodiment of the circuit combines the pulse generator and inductor in the form of an FET off line square wave generator with an impedance limited step up output transformer which is then applied to the full wave rectifier as before to yield a similar simmer current. 6 figures.

Steinkraus, R.F. Jr.

1994-12-13T23:59:59.000Z

457

Cold cathode vacuum discharge tube  

DOE Patents (OSTI)

A cold cathode vacuum discharge tube, and method for making same, with an interior surface of the trigger probe coated with carbon deposited by carbon vapor deposition (CVD) or diamond-like carbon (DLC) deposition. Preferably a solid graphite insert is employed in the probe-cathode structure in place of an aluminum bushing employed in the prior art. The CVD or DLC probe face is laser scribed to allow resistance trimming to match available trigger voltage signals and to reduce electrical aging.

Boettcher, Gordon E. (Albuquerque, NM)

1998-01-01T23:59:59.000Z

458

Film holder for radiographing tubing  

DOE Patents (OSTI)

A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

Davis, Earl V. (Oak Ridge, TN); Foster, Billy E. (Oak Ridge, TN)

1976-01-01T23:59:59.000Z

459

Underbalanced coiled tubing sidetrack successful  

Science Conference Proceedings (OSTI)

The technique of drilling through a completion string, underbalanced, with coiled tubing eliminated some of the problems encountered with overbalanced drilling in a group of offset wells. This project confirmed that performing drilling operations in live wells can be carried out safely and effectively. Dalen is a sour gas field in the eastern part of The Netherlands and produces from vertical fractures in the Zechstein carbonate reservoir. The proposal for Dalen 2 was to abandon the lower section of the original hole and subsequently sidetrack conventionally to the top of the reservoir, run and cement a 5-in. liner, complete the well with a 5-in. monobore completion, and install the christmas tree. This part of the operation would be performed with a workover hoist. Thereafter, a 3 3/4-in. hole would be drilled through the completion and into the reservoir, underbalanced with coiled tubing. The drilling proposal had to address a number of key issues: creating underbalanced conditions; handling sour gas production at surface; handling and treating drilling fluids at surface; removing drilled solids from the returned fluid system; and deploying a long coiled tubing drilling bottom hole assembly (BHA) into a live well. The paper discusses planning, legislative issues, well preparation, the drilling program, and lessons learned.

Adam, J.; Berry, M. [Nederlandse Aardolie Maatschappij B.V., Assen (Netherlands)

1995-12-18T23:59:59.000Z

460

Turbine nozzle stage having thermocouple guide tube  

SciTech Connect

A guide tube is fixed adjacent opposite ends in outer and inner covers of a nozzle stage segment. The guide tube is serpentine in shape between the outer and inner covers and extends through a nozzle vane. An insert is disposed in the nozzle vane and has apertures to accommodate serpentine portions of the guide tube. Cooling steam is also supplied through chambers of the insert on opposite sides of a central insert chamber containing the guide tube. The opposite ends of the guide tube are fixed to sleeves, in turn fixed to the outer and inner covers.

Schotsch, Margaret Jones (Greer, SC); Kirkpatrick, Francis Lawrence (late of Galway, NY); Lapine, Eric Michael (Northwood, NH)

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "refrigerant tubing suction" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Ceramic vacuum tubes for geothermal well logging  

DOE Green Energy (OSTI)

The results of investigations carried out into the availability and suitability of ceramic vacuum tubes for the development of logging tools for geothermal wells are summarized. Design data acquired in the evaluation of ceramic vacuum tubes for the development of a 500/sup 0/C instrumentation amplifier are presented. The general requirements for ceramic vacuum tubes for application to the development of high temperature well logs are discussed. Commercially available tubes are described and future contract activities that specifically relate to ceramic vacuum tubes are detailed. Supplemental data is presented in the appendix. (MHR)

Kelly, R.D.

1977-01-12T23:59:59.000Z

462

Portable Suction Lysimeter  

DOE Patents (OSTI)

A portable lysimeter including a collection vessel having an inflatable bladder and a semi-permeable member assembly at least partially movable in response to inflation of the bladder, a sample conduit in fluid communication with the semi-permeable member and a reservoir in fluid communication with the sample conduit.

Hubbell, Joel M. (Idaho Falls, ID); Sisson, James B. (Idaho Falls, ID)

2004-07-13T23:59:59.000Z

463

Minimum wear tube support hole design  

DOE Patents (OSTI)

A minimum-wear through-bore (16) is defined within a heat exchanger tube support plate (14) so as to have an hourglass configuration as determined by means of a constant radiused surface curvature (18) as defined by means of an external radius (R3), wherein the surface (18) extends between the upper surface (20) and lower surface (22) of the tube support plate (14). When a heat exchange tube (12) is disposed within the tube support plate (14) so as to pass through the through-bore (16), the heat exchange tube (12) is always in contact with a smoothly curved or radiused portion of the through-bore surface (16) whereby unacceptably excessive wear upon the heat exchange tube (12), as normally developed by means of sharp edges, lands, ridges, or the like conventionally part of the tube support plates, is eliminated or substantially reduced.

Glatthorn, Raymond H. (St. Petersburg, FL)

1986-01-01T23:59:59.000Z

464

Heat transfer characteristics of R410A-oil mixture flow boiling inside a 7 mm straight smooth tube  

SciTech Connect

Two-phase flow patterns and heat transfer characteristics of R410A-oil mixture flow boiling inside a straight smooth tube with the outside diameter of 7.0 mm were investigated experimentally. The experimental conditions include the evaporation temperature of 5 C, the mass flux from 200 to 400 kg m{sup -2} s{sup -1}, the heat flux from 7.56 to 15.12 kW m{sup -2}, the inlet vapor quality from 0.2 to 0.7, nominal oil concentration from 0% to 5%. The test results show that the heat transfer coefficient of R410A-oil mixture increases with mass flux of refrigerant-oil mixture; the presence of oil enhances the heat transfer at the range of low and intermediate vapor qualities; there is a peak of local heat transfer coefficient at about 2-4% nominal oil concentration at higher vapor qualities, and the peak shifts to lower nominal oil concentration with the increasing of vapor qualities; higher nominal oil concentration gives more detrimental effect at high vapor qualities. The flow pattern map of R410A-oil mixture was developed based on refrigerant-oil mixture properties, and the observed flow patterns match well with the flow pattern map. New correlation to predict the local heat transfer of R410A-oil mixture flow boiling inside the straight smooth tube was developed based on flow patterns and local properties of refrigerant-oil mixture, and it agrees with 90% of the experiment data within the deviation of {+-}25%. (author)

Hu, Haitao; Ding, Guoliang; Wei, Wenjian; Wang, Zhence [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Wang, Kaijian [Fujitsu General Institute of Air-Conditioning Technology Limited, Kawasaki 213-8502 (Japan)

2008-01-15T23:59:59.000Z

465

Thermoacoustic refrigerators and engines comprising cascading stirling thermodynamic units  

DOE Patents (OSTI)

The present invention includes a thermoacoustic assembly and method for improved efficiency. The assembly has a first stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator and at least one additional heat exchanger. The first stage Stirling thermal unit is serially coupled to a first end of a quarter wavelength long coupling tube. A second stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator, and at least one additional heat exchanger, is serially coupled to a second end of the quarter wavelength long coupling tube.

Backhaus, Scott; Swift, Greg

2013-06-25T23:59:59.000Z

466

ADVANCED UNDERGROUND GAS STORAGE CONCEPTS REFRIGERATED-MINED CAVERN STORAGE  

Science Conference Proceedings (OSTI)

Limited demand and high cost has prevented the construction of hard rock caverns in this country for a number of years. The storage of natural gas in mined caverns may prove technically feasible if the geology of the targeted market area is suitable; and economically feasible if the cost and convenience of service is competitive with alternative available storage methods for peak supply requirements. It is believed that mined cavern storage can provide the advantages of high delivery rates and multiple fill-withdrawal cycles in areas where salt cavern storage is not possible. In this research project, PB-KBB merged advanced mining technologies and gas refrigeration techniques to develop conceptual designs and cost estimates to demonstrate the commercialization potential of the storage of refrigerated natural gas in hard rock caverns. Five regions of the U.S.A. were studied for underground storage development and PB-KBB reviewed the literature to determine if the geology of these regions was suitable for siting hard rock storage caverns. Area gas market conditions in these regions were also studied to determine the need for such storage. Based on an analysis of many factors, a possible site was determined to be in Howard and Montgomery Counties, Maryland. The area has compatible geology and a gas industry infrastructure for the nearby market populous of Baltimore and Washington D.C.. As Gas temperature is lowered, the compressibility of the gas reaches an optimum value. The compressibility of the gas, and the resultant gas density, is a function of temperature and pressure. This relationship can be used to commercial advantage by reducing the size of a storage cavern for a given working volume of natural gas. This study looks at this relationship and and the potential for commercialization of the process in a storage application. A conceptual process design, and cavern design were developed for various operating conditions. Potential site locations were considered and a typical plant layout was developed. In addition a geomechanical review of the proposed cavern design was performed, evaluating the stability of the mine rooms and shafts, and the effects of the refrigerated gas temperatures on the stability of the cavern. Capital and operating cost estimates were also developed for the various temperature cases considered. The cost estimates developed were used to perform a comparative market analysis of this type of gas storage system to other systems that are commercially used in the region of the study.

NONE

1998-09-01T23:59:59.000Z

467

Optimization of finned-tube condensers using an intelligent ...  

Science Conference Proceedings (OSTI)

... with isobutane (R600a), R134a, propane (R290), R22 ... for determining the refrigerant state at the ... second ed., Hemisphere, New York, NY, USA, 1986 ...

2007-10-03T23:59:59.000Z

468

Multi-tube arrangement for combustor and method of making the multi-tube arrangement  

SciTech Connect

A fuel injector tube includes a one piece, unitary, polygonal tube having an inlet end and an outlet end. The fuel injector tube further includes a fuel passage extending from the inlet end to the outlet end along a longitudinal axis of the polygonal tube, a plurality of air passages extending from the inlet end to the outlet end and surrounding the fuel passage, and a plurality of fuel holes. Each fuel hole connects an air passage with the fuel passage. The inlet end of the polygonal tube is formed into a fuel tube. A fuel injector includes a plurality of fuel injector tubes and a plate. The plurality of fuel tubes are connected to the plate adjacent the inlet ends of the plurality of fuel injector tubes.

Ziminsky, Willy Steve (Simpsonville, SC)

2012-07-31T23:59:59.000Z

469

Advanced Underground Gas Storage Concepts Refrigerated-Mined Cavern Storage  

NLE Websites -- All DOE Office Websites (Extended Search)

UNDERGROUND GAS STORAGE CONCEPTS UNDERGROUND GAS STORAGE CONCEPTS REFRIGERATED-MINED CAVERN STORAGE FINAL REPORT DOE CONTRACT NUMBER DE-AC26-97FT34349 SUBMITTED BY: PB-KBB INC. 11757 KATY FREEWAY, SUITE 600 HOUSTON, TX 77079 SEPTEMBER 1998 Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily

470

Electrical applications for air conditioning and refrigeration systems  

Science Conference Proceedings (OSTI)

Electrical troubleshooting is possibly the most neglected area of maintaining air conditioning and refrigeration equipment. This text explains and illustrates methods for troubleshooting the full spectrum of electrical or electronic circuits of these systems. Comprehensive sections offer coverage of electrical fundamentals, single-phase electric motors, three-phase motors, control devices, electrical control circuits, use of schematic diagrams in troubleshooting, ice makers, solid state electronics, and basic electronic controls. The author`s clear, concise coverage of controls enables one to quickly understand both how a specific type of control works, and how it is used in the system. The reader will find a wealth of useful instructions for making operational checks and troubleshooting for proper operation. The book is conveniently divided into application-specific units, making it easy to quickly find information specific to a particular job at hand.

Langley, B.C.

1999-09-01T23:59:59.000Z

471

Triple effect absorption chiller utilizing two refrigeration circuits  

Science Conference Proceedings (OSTI)

This patent describes a heat absorption method for an absorption chiller. It comprises: providing a firs absorption system circuit for operation within a first temperature range, providing a second absorption system circuit for operation within a second temperature range; heat exchanging refrigerant and absorber solution; thermal communication with an external heat load. This patent describes a heat absorption apparatus for use as an absorption chiller. It includes: a first absorption system circuit for operation within a first temperature range; a second absorption system circuit for operation within a second temperature range which has a lower maximum temperature relative to the first temperature range; the first circuit having generator means, condenser means, evaporator means, and absorber means operatively connected together; the second circuit having generator means condenser means, evaporator means, and absorber means operative connected together; and the first circuit condenser means and the first circuit absorber means being in heat exchange communication with the second circuit generator means.

DeVault, R.C.

1988-03-22T23:59:59.000Z

472

Super Efficient Refrigerator Program (SERP) evaluation. Volume 1: Process evaluation  

Science Conference Proceedings (OSTI)

The Pacific Northwest National Laboratory (PNNL) conducted this study for the US Department of Energy (DOE) as part of the Super Efficient Refrigerator Program (SERP) Evaluation. This report documents the SERP formation and implementation process, and identifies preliminary program administration and implementation issues. The findings are based primarily on interviews with those familiar with the program, such as utilities, appliance manufacturers, and SERP administrators. These interviews occurred primarily between March and April 1995, when SERP was in the early stages of program implementation. A forthcoming report will estimate the preliminary impacts of SERP within the industry and marketplace. Both studies were funded by DOE at the request of SERP Inc., which sought a third-party evaluation of its program.

Sandahl, L.J.; Ledbetter, M.R.; Chin, R.I.; Lewis, K.S.; Norling, J.M.

1996-01-01T23:59:59.000Z

473