National Library of Energy BETA

Sample records for references wendi1 loading

  1. Model-reference adaptive control applied to load-following of a space-nuclear power system

    SciTech Connect (OSTI)

    Metzger, J.D.; El-Genk, M.S.; Parlos, A.G.; New Mexico Univ., Albuquerque, NM . Inst. for Space Nuclear Power Studies; Texas A and M Univ., College Station, TX . Dept. of Nuclear Engineering)

    1989-01-01

    Nuclear power systems are presently being investigated as an alternative for both commercial and military space power systems because of their projected longevity of 7 to 10 years, their mass advantage over other space power sources at powers above approximately 25 kW{sub e}, and their ability to operate without direct illumination from the sun. These space-nuclear power systems are being designed to supply from tens of kilowatts to multimegawatts of power for continuous operation of seven years and more. Space-nuclear power systems designs that meet these requirements will not be available for refueling or maintenance during their lifetime. To ensure that the space-nuclear power system will operate safely and will respond in a predictable and desired manner, the design of the system's controller must account for changes in the system parameters over its lifetime. This paper applies model-reference adaptive control to an increase in the power demand by the load. A model-reference adaptive controller will force the actual space-nuclear power system to follow the predictable and desired response of a reference model, despite changes in the actual system's operating parameters. Included in this paper are the model-reference adaptive control algorithm, the description of the computer simulation of a space-nuclear power system and the reference model, and results that demonstrate the application of model-reference adaptive control to a change in the load power demand. The results demonstrate that model-reference adaptive control can ensure the transient response of the system despite differences between the design of the system and the as-built system as well as for variations in the systems parameters. 5 refs., 3 figs.

  2. Load cell

    DOE Patents [OSTI]

    Spletzer, B.L.

    1998-12-15

    A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs, each directly proportional to one of the six general load components. 16 figs.

  3. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProtonAbout Us HanfordReference Materials Reference

  4. Reference Shelf

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProtonAbout Us HanfordReference MaterialsReference Shelf

  5. Poroelastic references

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Christina Morency

    2014-12-12

    This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

  6. Poroelastic references

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Christina Morency

    This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

  7. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProtonAbout Us Hanford SiteRecoveryWatertheReference

  8. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProtonAbout Us HanfordReference Materials

  9. Coal data: A reference

    SciTech Connect (OSTI)

    Not Available

    1995-02-01

    This report, Coal Data: A Reference, summarizes basic information on the mining and use of coal, an important source of energy in the US. This report is written for a general audience. The goal is to cover basic material and strike a reasonable compromise between overly generalized statements and detailed analyses. The section ``Supplemental Figures and Tables`` contains statistics, graphs, maps, and other illustrations that show trends, patterns, geographic locations, and similar coal-related information. The section ``Coal Terminology and Related Information`` provides additional information about terms mentioned in the text and introduces some new terms. The last edition of Coal Data: A Reference was published in 1991. The present edition contains updated data as well as expanded reviews and additional information. Added to the text are discussions of coal quality, coal prices, unions, and strikes. The appendix has been expanded to provide statistics on a variety of additional topics, such as: trends in coal production and royalties from Federal and Indian coal leases, hours worked and earnings for coal mine employment, railroad coal shipments and revenues, waterborne coal traffic, coal export loading terminals, utility coal combustion byproducts, and trace elements in coal. The information in this report has been gleaned mainly from the sources in the bibliography. The reader interested in going beyond the scope of this report should consult these sources. The statistics are largely from reports published by the Energy Information Administration.

  10. Professional References Ready Reference E-11

    E-Print Network [OSTI]

    Professional References Ready Reference E-11 College of Engineering, Architecture & Technology College of Engineering, Architecture & Technology Career Services Office ATRC 109E Stillwater, OK 74078 requested to do so. Create a separate sheet entitled "References." Print it on the same high quality papers

  11. Repository Reference Disposal Concepts and Thermal Load Management...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    parts: waste inventory (7 waste types examined), geologic setting (e.g., clayshale, salt, crystalline, other sedimentary), and the engineering concept of operations (range of...

  12. Repository Reference Disposal Concepts and Thermal Load Management Analysis

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematicsEnergyInterestedReplacement-2-A Wholesale Power Rate ScheduleSHERMANDepartmentReports|

  13. Load controller and method to enhance effective capacity of a photovotaic power supply using a dynamically determined expected peak loading

    DOE Patents [OSTI]

    Perez, Richard (Delmar, NY)

    2003-04-01

    A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The expected peak loading of the variable load can be dynamically determined within a defined time interval with reference to variations in the variable load.

  14. Load Management for Industry 

    E-Print Network [OSTI]

    Konsevick, W. J., Jr.

    1982-01-01

    categories: Thermal Energy Storage, Communication and Load Control, Interconnection and Operation of Power Systems, and Selective Load Promotions. The endeavors of the utility industry and Ohio Edison Company in three of the four categories are described...

  15. Load sensing system

    DOE Patents [OSTI]

    Sohns, Carl W. (Oak Ridge, TN); Nodine, Robert N. (Knoxville, TN); Wallace, Steven Allen (Knoxville, TN)

    1999-01-01

    A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast

  16. Emergency Information Desk Reference

    E-Print Network [OSTI]

    Gopalakrishnan, K.

    Emergency Information Desk Reference ECU Police Department ECU Environmental Health & Safety Revised Feb 2012 #12;Emergency Information Desk Reference 2 INTRODUCTION Emergencies, accidents, and injuries can occur at any time and without warning. ECU has designed this emergency information desk

  17. High frequency reference electrode

    DOE Patents [OSTI]

    Kronberg, J.W.

    1994-05-31

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes. 4 figs.

  18. High frequency reference electrode

    DOE Patents [OSTI]

    Kronberg, James W. (Aiken, SC)

    1994-01-01

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or "halo" at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes.

  19. Optical voltage reference

    DOE Patents [OSTI]

    Rankin, R.; Kotter, D.

    1994-04-26

    An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

  20. Optical voltage reference

    DOE Patents [OSTI]

    Rankin, Richard (Ammon, ID); Kotter, Dale (Bingham County, ID)

    1994-01-01

    An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.

  1. Load regulating expansion fixture

    DOE Patents [OSTI]

    Wagner, L.M.; Strum, M.J.

    1998-12-15

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig.

  2. HLW Glass Waste Loadings

    Office of Environmental Management (EM)

    HLW Glass Waste Loadings Ian L. Pegg Vitreous State Laboratory The Catholic University of America Washington, DC Overview Overview Vitrification - general background Joule...

  3. Load sensing system

    DOE Patents [OSTI]

    Sohns, C.W.; Nodine, R.N.; Wallace, S.A.

    1999-05-04

    A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast inventories of stored nuclear material can be continuously monitored and inventoried of minimal cost. 4 figs.

  4. Load regulating expansion fixture

    DOE Patents [OSTI]

    Wagner, Lawrence M. (San Jose, CA); Strum, Michael J. (San Jose, CA)

    1998-01-01

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components.

  5. Sandia Energy - Reference Model Documents

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Documents Home Stationary Power Energy Conversion Efficiency Water Power Reference Model Project (RMP) Reference Model Documents Reference Model DocumentsTara Camacho-Lopez2015-05-...

  6. Application Protocol Reference Architecture Application Protocol Reference Architecture

    E-Print Network [OSTI]

    van Sinderen, Marten

    Application Protocol Reference Architecture 165 Chapter 7 Application Protocol Reference Architecture This chapter proposes an alternative reference architecture for application protocols. The proposed reference architecture consists of the set of possible architectures for application protocols

  7. HAZARDOUS WASTE MANAGEMENT REFERENCE

    E-Print Network [OSTI]

    Winfree, Erik

    HAZARDOUS WASTE MANAGEMENT REFERENCE GUIDE Prepared by Environment, Health and Safety Office@caltech.edu http://safety.caltech.edu #12;Hazardous Waste Management Reference Guide Page 2 of 36 TABLE OF CONTENTS Satellite Accumulation Area 9 Waste Accumulation Facility 10 HAZARDOUS WASTE CONTAINER MANAGEMENT Labeling

  8. Reference Hashed Frank Schilder

    E-Print Network [OSTI]

    provides the reader with an introduction to hashing lists and how they can be used for linguistic dam data structure for the representation of discourse referents. A so-called hashing list is employed instead a novel data structure for the representation of discourse referents. A/rushing list t

  9. A loaded thermoacoustic engine

    SciTech Connect (OSTI)

    Olson, J.R.; Swift, G.W.

    1995-11-01

    Measurements and analysis of the performance of a thermoacoustic engine driving a dissipative load are presented. The effect of the load can be explained qualitatively using a simple low-amplitude approximation and quantitatively by invoking a more accurate low-amplitude numerical solution. The heater power {ital @};DQ and hot-end temperature {ital T}{sub {ital H}} are found to be simple functions of the load impedance and the unloaded values of {ital @};DQ and {ital T}{sub {ital H}}. {copyright} {ital 1995} {ital Acoustical} {ital Society} {ital of} {ital America}.

  10. Load research manual. Volume 3. Load research for advanced technologies

    SciTech Connect (OSTI)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. The manual includes guides to load research literature and glossaries of load research and statistical terms. In Volume 3, special load research procedures are presented for solar, wind, and cogeneration technologies.

  11. Value of Information References

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Morency, Christina

    2014-12-12

    This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

  12. Value of Information References

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Morency, Christina

    This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

  13. Precision displacement reference system

    DOE Patents [OSTI]

    Bieg, Lothar F. (Albuquerque, NM); Dubois, Robert R. (Albuquerque, NM); Strother, Jerry D. (Edgewood, NM)

    2000-02-22

    A precision displacement reference system is described, which enables real time accountability over the applied displacement feedback system to precision machine tools, positioning mechanisms, motion devices, and related operations. As independent measurements of tool location is taken by a displacement feedback system, a rotating reference disk compares feedback counts with performed motion. These measurements are compared to characterize and analyze real time mechanical and control performance during operation.

  14. Load Monitoring CEC/LMTF Load Research Program

    SciTech Connect (OSTI)

    Huang, Zhenyu; Lesieutre, B.; Yang, Steve; Ellis, A.; Meklin, A.; Wong, B.; Gaikwad, A.; Brooks, D.; Hammerstrom, Donald J.; Phillips, John; Kosterev, Dmitry; Hoffman, M.; Ciniglio, O.; Hartwell, R.; Pourbeik, P.; Maitra, A.; Lu, Ning

    2007-11-30

    This white paper addresses the needs, options, current practices of load monitoring. Recommendations on load monitoring applications and future directions are also presented.

  15. Aluminum reference electrode

    DOE Patents [OSTI]

    Sadoway, Donald R. (Belmont, MA)

    1988-01-01

    A stable reference electrode for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na.sub.3 AlF.sub.6, wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution.

  16. Aluminum reference electrode

    DOE Patents [OSTI]

    Sadoway, D.R.

    1988-08-16

    A stable reference electrode is described for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na[sub 3]AlF[sub 6], wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution. 1 fig.

  17. Multifunctional reference electrode

    DOE Patents [OSTI]

    Redey, L.; Vissers, D.R.

    1981-12-30

    A multifunctional, low mass reference electrode of a nickel tube, thermocouple means inside the nickel tube electrically insulated therefrom for measuring the temperature thereof, a housing surrounding the nickel tube, an electrolyte having a fixed sulfide ion activity between the housing and the outer surface of the nickel tube forming the nickel/nickel sulfide/sulfide half-cell are described. An ion diffusion barrier is associated with the housing in contact with the electrolyte. Also disclosed is a cell using the reference electrode to measure characteristics of a working electrode.

  18. Photovoltaic power converter system with a controller configured to actively compensate load harmonics

    DOE Patents [OSTI]

    de Rooij, Michael Andrew (Clifton Park, NY); Steigerwald, Robert Louis (Burnt Hills, NY); Delgado, Eladio Clemente (Burnt Hills, NY)

    2008-12-16

    Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

  19. Grant Reference Lead / Sole

    E-Print Network [OSTI]

    Rank Overall Score Grant Reference Lead / Sole Grant Grant Holder Research Organisation Project of Birmingham Controls on Soil Carbon Export revealed by Novel Tracers on multiple timescales (SCENT) Standard Grant DEC12 8 8 NE/K011871/1 N Melanie Leng NERC British Geological Survey A 500,000-year environmental

  20. Load research manual. Volume 1. Load research procedures

    SciTech Connect (OSTI)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  1. Measuring alignment of loading fixture

    DOE Patents [OSTI]

    Scavone, Donald W. (Saratoga Springs, NY)

    1989-01-01

    An apparatus and method for measuring the alignment of a clevis and pin type loading fixture for compact tension specimens include a pair of substantially identical flat loading ligaments. Each loading ligament has two apertures for the reception of a respective pin of the loading fixture and a thickness less than one-half of a width of the clevis opening. The pair of loading ligaments are mounted in the clevis openings at respective sides thereof. The loading ligaments are then loaded by the pins of the loading fixture and the strain in each loading ligament is measured. By comparing the relative strain of each loading ligament, the alignment of the loading fixture is determined. Preferably, a suitable strain gage device is located at each longitudinal edge of a respective loading ligament equidistant from the two apertures in order to determine the strain thereat and hence the strain of each ligament. The loading ligaments are made substantially identical by jig grinding the loading ligaments as a matched set. Each loading ligament can also be individually calibrated prior to the measurement.

  2. Load Management Made Simple 

    E-Print Network [OSTI]

    Schneider, K.

    1985-01-01

    Company have moved to a demand side or load management mode which seeks to influence customers to change electric usage patterns to more efficiently use available generating capacity. Since 1970, the TUEC system peak demand has more than doubled from about...

  3. OSH technical reference manual

    SciTech Connect (OSTI)

    Not Available

    1993-11-01

    In an evaluation of the Department of Energy (DOE) Occupational Safety and Health programs for government-owned contractor-operated (GOCO) activities, the Department of Labor`s Occupational Safety and Health Administration (OSHA) recommended a technical information exchange program. The intent was to share written safety and health programs, plans, training manuals, and materials within the entire DOE community. The OSH Technical Reference (OTR) helps support the secretary`s response to the OSHA finding by providing a one-stop resource and referral for technical information that relates to safe operations and practice. It also serves as a technical information exchange tool to reference DOE-wide materials pertinent to specific safety topics and, with some modification, as a training aid. The OTR bridges the gap between general safety documents and very specific requirements documents. It is tailored to the DOE community and incorporates DOE field experience.

  4. Electrical Load Modeling and Simulation

    SciTech Connect (OSTI)

    Chassin, David P.

    2013-01-01

    Electricity consumer demand response and load control are playing an increasingly important role in the development of a smart grid. Smart grid load management technologies such as Grid FriendlyTM controls and real-time pricing are making their way into the conventional model of grid planning and operations. However, the behavior of load both affects, and is affected by load control strategies that are designed to support electric grid planning and operations. This chapter discussed the natural behavior of electric loads, how it interacts with various load control and demand response strategies, what the consequences are for new grid operation concepts and the computing issues these new technologies raise.

  5. Buildings Stock Load Control 

    E-Print Network [OSTI]

    Joutey, H. A.; Vaezi-Nejad, H.; Clemoncon, B.; Rosenstein, F.

    2006-01-01

    , Shenzhen, China Building Commissioning for Energy Efficiency and Comfort, Vol.VI-9-4 Buildings Stock Load Control Ms H. Amrani Joutey Mr H. Vaezi-Nejad Mr B. Clemonçon Mr F.Rosenstein PHD student Research engineer Research... electricity consumption and curtail peak demand but in local form: building by building. Few developments are carried out for multi sites management. Multi sites management is essential in crisis and/or peak periods (large energy demand in particular during...

  6. Load responsive hydrodynamic bearing

    DOE Patents [OSTI]

    Kalsi, Manmohan S. (Houston, TX); Somogyi, Dezso (Sugar Land, TX); Dietle, Lannie L. (Stafford, TX)

    2002-01-01

    A load responsive hydrodynamic bearing is provided in the form of a thrust bearing or journal bearing for supporting, guiding and lubricating a relatively rotatable member to minimize wear thereof responsive to relative rotation under severe load. In the space between spaced relatively rotatable members and in the presence of a liquid or grease lubricant, one or more continuous ring shaped integral generally circular bearing bodies each define at least one dynamic surface and a plurality of support regions. Each of the support regions defines a static surface which is oriented in generally opposed relation with the dynamic surface for contact with one of the relatively rotatable members. A plurality of flexing regions are defined by the generally circular body of the bearing and are integral with and located between adjacent support regions. Each of the flexing regions has a first beam-like element being connected by an integral flexible hinge with one of the support regions and a second beam-like element having an integral flexible hinge connection with an adjacent support region. A least one local weakening geometry of the flexing region is located intermediate the first and second beam-like elements. In response to application of load from one of the relatively rotatable elements to the bearing, the beam-like elements and the local weakening geometry become flexed, causing the dynamic surface to deform and establish a hydrodynamic geometry for wedging lubricant into the dynamic interface.

  7. Shot loading trainer analysis

    SciTech Connect (OSTI)

    Peterson, T.K.

    1995-02-15

    This document presents the results from the analysis of the shot loading trainer (SLT). This device will be used to test the procedure for installing shot into the annulus of the Project W-320 shipping container. To ensure that the shot is installed uniformly around the container, vibrators will be used to settle the shot. The SLT was analyzed to ensure that it would not jeopardize worker safety during operation. The results from the static analysis of the SLT under deadweight and vibrator operating loads show that the stresses in the SLT are below code allowables. The results from the modal analysis show that the natural frequencies of the SLT are far below the operating frequencies of the vibrators, provided the SLT is mounted on pneumatic tires. The SLT was also analyzed for wind, seismic, deadweight, and moving/transporting loads. Analysis of the SLT is in accordance with SDC-4.1 for safety class 3 structures (DOE-RL 1993) and the American Institute of Steel Construction (AISC) Manual of Steel Construction (AISC 1989).

  8. Appendix A: Reference case

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet)Decade Year-0ProvedDecade2,948 2,724 2,570Month PreviousDry4,645 8244 Reference

  9. Appendix A: Reference case

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet)Decade Year-0ProvedDecade2,948 2,724 2,570Month PreviousDry4,645 8244 Reference6

  10. Appendix A: Reference case

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet)Decade Year-0ProvedDecade2,948 2,724 2,570Month PreviousDry4,645 8244 Reference64

  11. Appendix A: Reference case

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet)Decade Year-0ProvedDecade2,948 2,724 2,570Month PreviousDry4,645 82444 Reference

  12. Appendix A: Reference case

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet)Decade Year-0ProvedDecade2,948 2,724 2,570Month PreviousDry4,645 82444 Reference6

  13. Manufacturing Energy and Carbon Footprint References | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    References Manufacturing Energy and Carbon Footprint References footprintreferences.pdf More Documents & Publications 2010 Manufacturing Energy and Carbon Footprints: References...

  14. Load Management: Opportunity or Calamity? 

    E-Print Network [OSTI]

    Males, R.; Hassig, N.

    1981-01-01

    larger now than prior to 1973. Utilities are examining two options which can be termed load management. One option is to control discretionary loads during peak periods. Cycling of residential water heaters or shutting off industrial electric furnaces...

  15. Tank characterization reference guide

    SciTech Connect (OSTI)

    De Lorenzo, D.S.; DiCenso, A.T.; Hiller, D.B.; Johnson, K.W.; Rutherford, J.H.; Smith, D.J. [Los Alamos Technical Associates, Kennewick, WA (United States); Simpson, B.C. [Westinghouse Hanford Co., Richland, WA (United States)

    1994-09-01

    Characterization of the Hanford Site high-level waste storage tanks supports safety issue resolution; operations and maintenance requirements; and retrieval, pretreatment, vitrification, and disposal technology development. Technical, historical, and programmatic information about the waste tanks is often scattered among many sources, if it is documented at all. This Tank Characterization Reference Guide, therefore, serves as a common location for much of the generic tank information that is otherwise contained in many documents. The report is intended to be an introduction to the issues and history surrounding the generation, storage, and management of the liquid process wastes, and a presentation of the sampling, analysis, and modeling activities that support the current waste characterization. This report should provide a basis upon which those unfamiliar with the Hanford Site tank farms can start their research.

  16. Nuclear Science References Database

    E-Print Network [OSTI]

    B. Pritychenko; E. B?ták; B. Singh; J. Totans

    2014-07-08

    The Nuclear Science References (NSR) database together with its associated Web interface, is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 210,000 articles since the beginning of nuclear science. The weekly-updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center http://www.nndc.bnl.gov/nsr and the International Atomic Energy Agency http://www-nds.iaea.org/nsr.

  17. Multidimensional spectral load balancing

    SciTech Connect (OSTI)

    Hendrickson, B.; Leland, R.

    1993-01-01

    We describe an algorithm for the static load balancing of scientific computations that generalizes and improves upon spectral bisection. Through a novel use of multiple eigenvectors, our new spectral algorithm can divide a computation into 4 or 8 pieces at once. These multidimensional spectral partitioning algorithms generate balanced partitions that have lower communication overhead and are less expensive to compute than those produced by spectral bisection. In addition, they automatically work to minimize message contention on a hypercube or mesh architecture. These spectral partitions are further improved by a multidimensional generalization of the Kernighan-Lin graph partitioning algorithm. Results on several computational grids are given and compared with other popular methods.

  18. Variable loading roller

    DOE Patents [OSTI]

    Williams, Daniel M. (Oliver Springs, TN)

    1989-01-01

    An automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves on the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first.

  19. Variable loading roller

    DOE Patents [OSTI]

    Williams, D.M.

    1988-01-21

    An automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves in the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first. 14 figs.

  20. Sensor Characteristics Reference Guide

    SciTech Connect (OSTI)

    Cree, Johnathan V.; Dansu, A.; Fuhr, P.; Lanzisera, Steven M.; McIntyre, T.; Muehleisen, Ralph T.; Starke, M.; Banerjee, Pranab; Kuruganti, T.; Castello, C.

    2013-04-01

    The Buildings Technologies Office (BTO), within the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), is initiating a new program in Sensor and Controls. The vision of this program is: • Buildings operating automatically and continuously at peak energy efficiency over their lifetimes and interoperating effectively with the electric power grid. • Buildings that are self-configuring, self-commissioning, self-learning, self-diagnosing, self-healing, and self-transacting to enable continuous peak performance. • Lower overall building operating costs and higher asset valuation. The overarching goal is to capture 30% energy savings by enhanced management of energy consuming assets and systems through development of cost-effective sensors and controls. One step in achieving this vision is the publication of this Sensor Characteristics Reference Guide. The purpose of the guide is to inform building owners and operators of the current status, capabilities, and limitations of sensor technologies. It is hoped that this guide will aid in the design and procurement process and result in successful implementation of building sensor and control systems. DOE will also use this guide to identify research priorities, develop future specifications for potential market adoption, and provide market clarity through unbiased information

  1. Dynamic load balancing of applications

    DOE Patents [OSTI]

    Wheat, S.R.

    1997-05-13

    An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers is disclosed. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated. 13 figs.

  2. Dynamic load balancing of applications

    DOE Patents [OSTI]

    Wheat, Stephen R. (Albuquerque, NM)

    1997-01-01

    An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated.

  3. Electrical and Production Load Factors 

    E-Print Network [OSTI]

    Sen, T.; Heffington, W. M.

    2009-01-01

    factors and operating hours of small and medium-sized industrial plants are analyzed to classify shift-work patterns and develop energy conservation diagnostic tools. This paper discusses two types of electric load factors for each shift... The purpose of this paper is to analyze operating hours of small and medium-sized manufacturing plants in the United States and develop ranges of load factors for use as diagnostic tools for effective energy management. Load factor is defined...

  4. High-Power Rf Load

    DOE Patents [OSTI]

    Tantawi, Sami G. (San Mateo, CA); Vlieks, Arnold E. (Livermore, CA)

    1998-09-01

    A compact high-power RF load comprises a series of very low Q resonators, or chokes [16], in a circular waveguide [10]. The sequence of chokes absorb the RF power gradually in a short distance while keeping the bandwidth relatively wide. A polarizer [12] at the input end of the load is provided to convert incoming TE.sub.10 mode signals to circularly polarized TE.sub.11 mode signals. Because the load operates in the circularly polarized mode, the energy is uniformly and efficiently absorbed and the load is more compact than a rectangular load. Using these techniques, a load having a bandwidth of 500 MHz can be produced with an average power dissipation level of 1.5 kW at X-band, and a peak power dissipation of 100 MW. The load can be made from common lossy materials, such as stainless steel, and is less than 15 cm in length. These techniques can also produce loads for use as an alternative to ordinary waveguide loads in small and medium RF accelerators, in radar systems, and in other microwave applications. The design is easily scalable to other RF frequencies and adaptable to the use of other lossy materials.

  5. Optical probe with reference fiber

    DOE Patents [OSTI]

    Da Silva, Luiz B. (Danville, CA); Chase, Charles L. (Dublin, CA)

    2006-03-14

    A system for characterizing tissue includes the steps of generating an emission signal, generating a reference signal, directing the emission signal to and from the tissue, directing the reference signal in a predetermined manner relative to the emission signal, and using the reference signal to compensate the emission signal. In one embodiment compensation is provided for fluctuations in light delivery to the tip of the probe due to cable motion.

  6. FAQS Reference Guide – Construction Management

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the March 2004 edition of DOE-STD-1180-2004, Construction Management Functional Area Qualification Standard.

  7. FAQS Reference Guide – Industrial Hygiene

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the November 2007 edition of DOE-STD-1138-2007, Industrial Hygiene Functional Area Qualification Standard.

  8. FAQS Reference Guide – Emergency Management

    Office of Energy Efficiency and Renewable Energy (EERE)

    This reference guide addresses the competency statements in the January 2004 edition of DOE-STD-1177-2004, Emergency Management Functional Area Qualification Standard.

  9. FAQS Reference Guide- Chemical Processing

    Office of Energy Efficiency and Renewable Energy (EERE)

    This reference guide addresses the competency statements in the February 2010 edition of DOE-STD-1176-2010, Chemical Processing Functional Area Qualification Standard.

  10. FAQS Reference Guide – Environmental Compliance

    Office of Energy Efficiency and Renewable Energy (EERE)

    This reference guide addresses the competency statements in the June 2011 edition of DOE-STD-1156-2011, Environmental Compliance Functional Area Qualification Standard.

  11. Ris Energy Report 5 References References for Chapter 3

    E-Print Network [OSTI]

    Risř Energy Report 5 References References for Chapter 3 1. UNEP. (2006). Background paper for the ministerial-level consultations on energy and environment for development. Ninth special session energy outlook 2005. Paris: IEA. 3. IEA. (2003). World energy investment outlook. Paris: IEA. 4. World

  12. Ris Energy Report 6 References Reference list for Chapter 3

    E-Print Network [OSTI]

    Risř Energy Report 6 References Reference list for Chapter 3 1. European Commission. (2007). Communication from the Commis- sion to the European Council and the European Parliament ­ An energy policy of the Brussels European Council 8/9 March 2007. Brussels. (7224/1/07 Rev. 1). 3. Danish Energy authority. (2007

  13. LOAD FORECASTING Eugene A. Feinberg

    E-Print Network [OSTI]

    Feinberg, Eugene A.

    , regression, artificial intelligence. 1. Introduction Accurate models for electric power load forecasting to make important decisions including decisions on pur- chasing and generating electric power, load for different operations within a utility company. The natures 269 #12;270 APPLIED MATHEMATICS FOR POWER SYSTEMS

  14. Load Management - A Better Way 

    E-Print Network [OSTI]

    Easley, J. F.

    1982-01-01

    of load management techniques which has enabled the company to shift well over 100,000 kilowatts of customer load from the on-peak period to the off-peak period in the last four to five years. This is helping delay the need for new plants and allows...

  15. Archived Reference Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  17. R Reference Card by Tom Short, EPRI PEAC, tshort@epri-peac.com 2004-11-07

    E-Print Network [OSTI]

    Miller, Thomas E.

    R Reference Card by Tom Short, EPRI PEAC, tshort@epri-peac.com 2004-11-07 Granted to the public by Emmanuel Paradis (with permission). Getting help Most R functions have online documentation. help with save data(x) loads specified data sets library(x) load add-on packages read.table(file) reads a file

  18. Sandia Energy - Technical Reference for Hydrogen Compatibility...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Technical Reference for Hydrogen Compatibility of Materials Home Transportation Energy Hydrogen Materials & Components Compatibility Technical Reference for Hydrogen Compatibility...

  19. Spinning Reserve from Responsive Load

    SciTech Connect (OSTI)

    Kueck, John D; Kirby, Brendan J; Laughner, T; Morris, K

    2009-01-01

    As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host a spinning reserve test. The Tennessee Valley Authority (TVA) supplied real-time metering and monitoring expertise to record total hotel load during both normal operations and testing. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. The load drop was very rapid, essentially as fast as the 2 second metering could detect.

  20. Electrical and Production Load Factors 

    E-Print Network [OSTI]

    Sen, Tapajyoti

    2010-07-14

    Load factors are an important simplification of electrical energy use data and depend on the ratio of average demand to peak demand. Based on operating hours of a facility they serve as an important benchmarking tool for the industrial sector...

  1. Sandia Wind Turbine Loads Database

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    The Sandia Wind Turbine Loads Database is divided into six files, each corresponding to approximately 16 years of simulation. The files are text files with data in columnar format. The 424MB zipped file containing six data files can be downloaded by the public. The files simulate 10-minute maximum loads for the NREL 5MW wind turbine. The details of the loads simulations can be found in the paper: “Decades of Wind Turbine Loads Simulations”, M. Barone, J. Paquette, B. Resor, and L. Manuel, AIAA2012-1288 (3.69MB PDF). Note that the site-average wind speed is 10 m/s (class I-B), not the 8.5 m/s reported in the paper.

  2. Building load control and optimization

    E-Print Network [OSTI]

    Xing, Hai-Yun Helen, 1976-

    2004-01-01

    Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on load control by improving the operations in existing building HVAC ...

  3. Loading and conjugating cavity biostructures

    DOE Patents [OSTI]

    Hainfeld, J.F.

    1997-11-25

    Methods for the preparation and use of a biological delivery system are disclosed. The method of preparation includes the loading of a non-biological material into a biostructure having a load-bearing structure. The method also includes the removal of some of the biostructure`s contents and the loading of a non-biological material into the biostructure. The biostructure is biologically compatible with the host, and preferably is derived from the host, the host`s species or a related species. The loaded biostructure is used directly, or it can be targeted to specific cells, tissues and/or organs within a host. The targeted biostructure can be used to deliver the non-biological material to a specified tissue, organ or cell within a host for diagnostic, therapeutic or other purposes. 11 figs.

  4. SAM Photovoltaic Model Technical Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SAM Photovoltaic Model Technical Reference P. Gilman National Renewable Energy Laboratory Technical Report NRELTP-6A20-64102 May 2015 NREL is a national laboratory of the U.S....

  5. Emergency Preparedness Desk Reference Manual

    E-Print Network [OSTI]

    Patzek, Tadeusz W.

    Emergency Preparedness Desk Reference Manual Important Phone Numbers Medical Emergencies / Hazardous Material Fire Emergencies Vehicle Accidents Evacuation Weather Emergencies Building/System Problem or Failure Threat of Violence Terrorism Interpersonal Emergencies Next Page >>> #12;Important Phone Numbers

  6. FAQS Reference Guide – Occupational Safety

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the July 2011 version of DOE-STD-1160-2011, Occupational Safety Functional Area Qualification Standard.

  7. Safeguards and Security Program References

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2005-08-26

    The manual establishes definitions for terms related to the Department of Energy Safeguards and Security (S&S) Program and includes lists of references and acronyms/abbreviations applicable to S&S Program directives. Cancels the Safeguards and Security Glossary of Terms, dated 12-18-95. Current Safeguards and Security Program References can also be found at Safeguards and Security Policy Information Resource (http://pir.pnl.gov/)

  8. Demand Response: Load Management Programs 

    E-Print Network [OSTI]

    Simon, J.

    2012-01-01

    Management Programs CATEE Conference October, 2012 Agenda Outline I. General Demand Response Definition II. General Demand Response Program Rules III. CenterPoint Commercial Program IV. CenterPoint Residential Programs V. Residential Discussion... Points Demand Response Definition of load management per energy efficiency rule 25.181: ? Load control activities that result in a reduction in peak demand, or a shifting of energy usage from a peak to an off-peak period or from high-price periods...

  9. Structural assessment of accident loads

    SciTech Connect (OSTI)

    Wagenblast, G.R., Westinghouse Hanford

    1996-05-28

    Structural assessments were made for specific accident loads for specific catch, receiver, and storage tanks. The evaluation herein represents level-of-effort order-of-magnitude estimates of limiting loads that would lead to collapse or rupture of the tank and unmitigated loss of confinement for the waste. Structural capacities were established using failure criteria. Compliance with codes such as ACI, ASCE, ASME, RCRA, UBC, WAC, and DOE Orders was `NOT` maintained. Normal code practice is to prevent failure with margins consistent with expected variations in loads and strengths and confidence in analysis techniques. The evaluation herein represent estimates of code limits without code load factors or code strength reduction factors, and loading beyond such a limit is considered as an onset of some failure mode. The exact nature of the failure mode and its relation to a safe condition is a judgment of the analyst. Consequently, these `RESULTS SHALL NOT BE USED TO ESTABLISH OPERATING OR SAFETY LOAD LIMITS FOR THESE TANKS`.

  10. Cooling load design tool for UFAD systems.

    E-Print Network [OSTI]

    Bauman, Fred; Schiavon, Stefano; Webster, Tom; Lee, Kwang Ho

    2010-01-01

    De- velopment of a Simplified Cooling Load Design Tool forand C. Benedek. 2007. “Cooling airflow design calculationscalculation method for design cooling loads in underfloor

  11. Laser Driven Dynamic Loading of Condensed Matter

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Laser Driven Dynamic Loading of Condensed Matter Laser Driven Dynamic Loading of Condensed Matter Advanced diagnostics of experiments covering many orders of magnitude in strain...

  12. Load Participation in Ancillary Services Workshop Report

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    controls on the load-side is growing. Driven by improved and widely available communications systems, load participation is becoming easier and more reliable; and there...

  13. Self-aligning biaxial load frame

    DOE Patents [OSTI]

    Ward, M.B.; Epstein, J.S.; Lloyd, W.R.

    1994-01-18

    An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed cross head, and by alignment and linear motion elements of one load assembly relative to the load frame. 3 figures.

  14. REFERENCES

    E-Print Network [OSTI]

    2008-08-23

    Mechanism of Fluid Displacement in Sands. Trans. Am. Inst. Min. Metall. Eng.,. 146: 107-116. Chaudhari, N.M., 1971. An Improved Numerical Technique for ...

  15. REFERENCES

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    5 United States Code (U.S.C.) Section 552a. . b. P.L. 104-106, Division E, Clinger Cohen Act (CCA) (formerly Information Technology Management Reform Act of 1996. c. P.L....

  16. {Control of Residential Load Management Networks Using Real Time Pricing

    E-Print Network [OSTI]

    Burke, William Jerome

    2010-01-01

    modeling and control of load management. Further, withoutA profit-based load management using linear programming”.with applica- tions to load management assessment and load

  17. Staying FIT: Efficient Load Shedding Techniques for Distributed Stream Processing

    E-Print Network [OSTI]

    . Bottlenecks slow down processing and network transmission, and cause delayed outputs. Load management has been. Common load management techniques include adaptive load distribution, admis- sion control, and load

  18. Fast Reference-Based MRI

    E-Print Network [OSTI]

    Weizman, Lior; Ben-Basaht, Dafna

    2015-01-01

    In many clinical MRI scenarios, existing imaging information can be used to significantly shorten acquisition time or to improve Signal to Noise Ratio (SNR). In some cases, a previously acquired image can serve as a reference image, that may exhibit similarity to the image being acquired. Examples include similarity between adjacent slices in high resolution MRI, similarity between various contrasts in the same scan and similarity between different scans of the same patient. In this paper we present a general framework for utilizing reference images for fast MRI. We take into account that the reference image may exhibit low similarity with the acquired image and develop an iterative weighted approach for reconstruction, which tunes the weights according to the degree of similarity. Experiments demonstrate the performance of the method in three different clinical MRI scenarios: SNR improvement in high resolution brain MRI, utilizing similarity between T2-weighted and fluid-attenuated inversion recovery (FLAIR)...

  19. WECC Variable Generation Planning Reference Book: Appendices

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Du, Pengwei; Etingov, Pavel V.; Ma, Jian; Vyakaranam, Bharat

    2013-05-13

    The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

  20. Noise Load Management at Amsterdam Airport Schiphol

    E-Print Network [OSTI]

    Boucherie, Richard J.

    Noise Load Management at Amsterdam Airport Schiphol T.R. Meerburg , R.J. Boucherie , M.J.A.L. van objective is to guarantee safety, efficiency, and protection of the environment, that includes noise load contributes to the noise load at these points. If the cumulative load in an aviation year at an enforce- ment

  1. Overall U-values and heating/cooling loads: Manufactured homes

    SciTech Connect (OSTI)

    Conner, C.C.; Taylor, Z.T.

    1992-02-01

    This manual specifies a method for calculating the overall thermal transmittance (also referred to as the overall U-value or U{sub o}), heating load, and cooling load of a manufactured (mobile) home. Rules, examples, and data required by the method are also presented. Compliance with the Department of Housing and Urban Development`s (HUD) U{sub o} and load calculation regulations contained in Sections 3280.506, 3280.510 and 3280.511 of the Manufactured Home Construction and Safety Standards must be demonstrated through the application of the method provided herein.

  2. Simulations of Lithium-Based Neutron Coincidence Counter for Gd-Loaded Fuel

    SciTech Connect (OSTI)

    Cowles, Christian C.; Kouzes, Richard T.; Siciliano, Edward R.

    2014-10-31

    The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Lithium-Based Alternative Neutron Detection Technology Coincidence Counting for Gd-loaded Fuels at Pacific Northwest National Laboratory for the development of a lithium-based neutron coincidence counter for nondestructively assaying Gd loaded nuclear fuel. This report provides results from MCNP simulations of a lithium-based coincidence counter for the possible measurement of Gd-loaded nuclear fuel. A comparison of lithium-based simulations and UNCL-II simulations with and without Gd loaded fuel is provided. A lithium-based model, referred to as PLNS3A-R1, showed strong promise for assaying Gd loaded fuel.

  3. LCCP Desktop Application v1.0 Engineering Reference

    SciTech Connect (OSTI)

    Beshr, Mohamed; Aute, Vikrant

    2014-04-01

    This Life Cycle Climate Performance (LCCP) Desktop Application Engineering Reference is divided into three parts. The first part of the guide, consisting of the LCCP objective, literature review, and mathematical background, is presented in Sections 2-4. The second part of the guide (given in Sections 5-10) provides a description of the input data required by the LCCP desktop application, including each of the input pages (Application Information, Load Information, and Simulation Information) and details for interfacing the LCCP Desktop Application with the VapCyc and EnergyPlus simulation programs. The third part of the guide (given in Section 11) describes the various interfaces of the LCCP code.

  4. Title: Information theory Reference: 13791

    E-Print Network [OSTI]

    Overill, Richard E.

    environment or communicates with others. One of the fundamental tenets of information theory a spate of publications appeared applying information theory to many aspects of music analysisTitle: Information theory Reference: 13791 Sort key: informationtheory Version: 3.0 Revision

  5. / R Reference May 25, 2010

    E-Print Network [OSTI]

    Loon, E. Emiel van

    of time searching for a simple way to do what I wanted, but at the end of the semester, I was pleasantly that the entire resulting derived work is distributed under the terms of a permission notice identical to this one, Matlab / R Reference 2 Contents 1 Help 3 2 Entering/building/indexing matrices 3 2.1 Cell arrays

  6. Reference Workbook: Pollution Prevention Plans

    E-Print Network [OSTI]

    #12;Reference Workbook: Pollution Prevention Plans DOE FRAP 1994-35 Prepared for: I Environment Canada Environmental Protection Fraser Pollution Abatement Office 224 West Esplanade North Vancouver, B Pollution Abatement Office. Environment Canada is not responsible for the content of this report but has

  7. References: Elmasri/Navathe:Fundamentals

    E-Print Network [OSTI]

    Brass, Stefan

    7. SQL I 7­1 Part 7: SQL I References: . Elmasri/Navathe:Fundamentals of Database Systems, 3rd Edition, 1999. Chap. 8, ``SQL --- The Relational Database Standard'' (Sect. 8.2, 8.3.3, part of 8. . Date/Darwen: A Guide to the SQL Standard, Fourth Edition, Addison­Wesley , 1997. . Date: A Guide

  8. EMERGENCY PROCEDURES QUICK REFERENCE GUIDE

    E-Print Network [OSTI]

    Frantz, Kyle J.

    1 EMERGENCY PROCEDURES QUICK REFERENCE GUIDE GSU EMERGENCY MANAGEMENT 404-413-0783 GSU POLICE: 404-413-3333 ATLANTA FIRE RESUCE: 911 #12;2 Emergency Response - Order of Priority In any emergency situation, Georgia infrastructure and facilities 3. Resume our research and educational programs Emergency Action Levels: A. Level 1

  9. Load Forecasting of Supermarket Refrigeration

    E-Print Network [OSTI]

    @compute.dtu.dk www.compute.dtu.dk M.Sc.-2013-87 #12;Summary (English) The Danish power production coming from energy system. Observed refrigeration load and local ambient temperature from a Danish su- permarket renewable energy, is increasing, therefore a flexible energy system is needed. In the present Thesis

  10. Scaling the Web Load Testing

    E-Print Network [OSTI]

    Menascé, Daniel A.

    Scaling the Web Load Testing of Web Sites D evelopers typically measure a Web appli- cation on a Web site's IT infrastructure are a function of the site's expect- ed traffic. Ideally, you want, you shouldn't upgrade your Web servers if customers experience most delays in the database server

  11. Plug and Process Loads Capacity and Power Requirements Analysis

    SciTech Connect (OSTI)

    Sheppy, M.; Gentile-Polese, L.

    2014-09-01

    This report addresses gaps in actionable knowledge that would help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. Limited initial data, however, suggest that actual PPL densities in leased buildings are substantially lower. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems. Better guidance will enable improved sizing and design of these systems, decrease upfront capital costs, and allow systems to operate more energy efficiently. The main focus of this report is to provide industry with reliable, objective third-party guidance to address the information gap in typical PPL densities for commercial building tenants. This could drive changes in negotiations about PPL energy demands.

  12. Microgrid cyber security reference architecture.

    SciTech Connect (OSTI)

    Veitch, Cynthia K.; Henry, Jordan M.; Richardson, Bryan T.; Hart, Derek H.

    2013-07-01

    This document describes a microgrid cyber security reference architecture. First, we present a high-level concept of operations for a microgrid, including operational modes, necessary power actors, and the communication protocols typically employed. We then describe our motivation for designing a secure microgrid; in particular, we provide general network and industrial control system (ICS)-speci c vulnerabilities, a threat model, information assurance compliance concerns, and design criteria for a microgrid control system network. Our design approach addresses these concerns by segmenting the microgrid control system network into enclaves, grouping enclaves into functional domains, and describing actor communication using data exchange attributes. We describe cyber actors that can help mitigate potential vulnerabilities, in addition to performance bene ts and vulnerability mitigation that may be realized using this reference architecture. To illustrate our design approach, we present a notional a microgrid control system network implementation, including types of communica- tion occurring on that network, example data exchange attributes for actors in the network, an example of how the network can be segmented to create enclaves and functional domains, and how cyber actors can be used to enforce network segmentation and provide the neces- sary level of security. Finally, we describe areas of focus for the further development of the reference architecture.

  13. Emergency Responder Radioactive Material Quick Reference Sheet

    Broader source: Energy.gov [DOE]

    Transportation Emergency Preparedness Program (TEPP) Emergency Responder Radioactive Material Quick Reference Sheet

  14. Generic Argillite/Shale Disposal Reference Case

    E-Print Network [OSTI]

    Zheng, Liange

    2014-01-01

    Shale Disposal Reference Case August 2014 Borehole activity: Oil and gas drilling targets for hydrocarbon resource

  15. Reference Inflow Characterization for River Resource Reference Model (RM2)

    SciTech Connect (OSTI)

    Neary, Vincent S [ORNL

    2011-12-01

    Sandia National Laboratory (SNL) is leading an effort to develop reference models for marine and hydrokinetic technologies and wave and current energy resources. This effort will allow the refinement of technology design tools, accurate estimates of a baseline levelized cost of energy (LCoE), and the identification of the main cost drivers that need to be addressed to achieve a competitive LCoE. As part of this effort, Oak Ridge National Laboratory was charged with examining and reporting reference river inflow characteristics for reference model 2 (RM2). Published turbulent flow data from large rivers, a water supply canal and laboratory flumes, are reviewed to determine the range of velocities, turbulence intensities and turbulent stresses acting on hydrokinetic technologies, and also to evaluate the validity of classical models that describe the depth variation of the time-mean velocity and turbulent normal Reynolds stresses. The classical models are found to generally perform well in describing river inflow characteristics. A potential challenge in river inflow characterization, however, is the high variability of depth and flow over the design life of a hydrokinetic device. This variation can have significant effects on the inflow mean velocity and turbulence intensity experienced by stationary and bottom mounted hydrokinetic energy conversion devices, which requires further investigation, but are expected to have minimal effects on surface mounted devices like the vertical axis turbine device designed for RM2. A simple methodology for obtaining an approximate inflow characterization for surface deployed devices is developed using the relation umax=(7/6)V where V is the bulk velocity and umax is assumed to be the near-surface velocity. The application of this expression is recommended for deriving the local inflow velocity acting on the energy extraction planes of the RM2 vertical axis rotors, where V=Q/A can be calculated given a USGS gage flow time-series and stage vs. cross-section area rating relationship.

  16. Direct versus Facility Centric Load Control for Automated Demand Response

    SciTech Connect (OSTI)

    Koch, Ed; Piette, Mary Ann

    2009-11-06

    Direct load control (DLC) refers to the scenario where third party entities outside the home or facility are responsible for deciding how and when specific customer loads will be controlled in response to Demand Response (DR) events on the electric grid. Examples of third parties responsible for performing DLC may be Utilities, Independent System Operators (ISO), Aggregators, or third party control companies. DLC can be contrasted with facility centric load control (FCLC) where the decisions for how loads are controlled are made entirely within the facility or enterprise control systems. In FCLC the facility owner has more freedom of choice in how to respond to DR events on the grid. Both approaches are in use today in automation of DR and both will continue to be used in future market segments including industrial, commercial and residential facilities. This paper will present a framework which can be used to differentiate between DLC and FCLC based upon where decisions are made on how specific loads are controlled in response to DR events. This differentiation is then used to compare and contrast the differences between DLC and FCLC to identify the impact each has on:(1)Utility/ISO and third party systems for managing demand response, (2)Facility systems for implementing load control, (3)Communications networks for interacting with the facility and (4)Facility operators and managers. Finally a survey of some of the existing DR related specifications and communications standards is given and their applicability to DLC or FCLC. In general FCLC adds more cost and responsibilities to the facilities whereas DLC represents higher costs and complexity for the Utility/ISO. This difference is primarily due to where the DR Logic is implemented and the consequences that creates. DLC may be more certain than FCLC because it is more predictable - however as more loads have the capability to respond to DR signals, people may prefer to have their own control of end-use loads and FCLC systems. Research is needed to understand the predictability of FCLC which is related to the perceived value of the DR from the facility manager or home owner's perspective.

  17. An Adjustable Robust Optimization Approach to Scheduling of Continuous Industrial Processes Providing Interruptible Load

    E-Print Network [OSTI]

    Grossmann, Ignacio E.

    by reducing electricity consumption Also referred to as interruptible load Can be regarded as spinning as the maximum possible reduction in electricity consumption that can be requested by the grid operator for large industrial electricity consumers Target power consumption Minimum power consumption Time Power

  18. Load-shedding probabilities with hybrid renewable power generation and energy storage

    E-Print Network [OSTI]

    Xu, Huan

    Load-shedding probabilities with hybrid renewable power generation and energy storage Huan Xu, Ufuk, and energy storage. costs [7], [8], [9]. Reference [10] uses a probabilistic model to predict the feasibility Topcu, Steven H. Low, Christopher R. Clarke, and K. Mani Chandy Abstract-- The integration of renewable

  19. Spinning Reserve From Responsive Loads

    SciTech Connect (OSTI)

    Kirby, B.J.

    2003-04-08

    Responsive load is the most underutilized reliability resource available to the power system today. It is currently not used at all to provide spinning reserve. Historically there were good reasons for this, but recent technological advances in communications and controls have provided new capabilities and eliminated many of the old obstacles. North American Electric Reliability Council (NERC), Federal Energy Regulatory Commission (FERC), Northeast Power Coordinating Council (NPCC), New York State Reliability Council (NYSRC), and New York Independent System Operator (NYISO) rules are beginning to recognize these changes and are starting to encourage responsive load provision of reliability services. The Carrier ComfortChoice responsive thermostats provide an example of these technological advances. This is a technology aimed at reducing summer peak demand through central control of residential and small commercial air-conditioning loads. It is being utilized by Long Island Power Authority (LIPA), Consolidated Edison (ConEd), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E). The technology is capable of delivering even greater response in the faster spinning reserve time frame (while still providing peak reduction). Analysis of demand reduction testing results from LIPA during the summer of 2002 provides evidence to back up this claim. It also demonstrates that loads are different from generators and that the conventional wisdom, which advocates for starting with large loads as better ancillary service providers, is flawed. The tempting approach of incrementally adapting ancillary service requirements, which were established when generators were the only available resources, will not work. While it is easier for most generators to provide replacement power and non-spinning reserve (the slower response services) than it is to supply spinning reserve (the fastest service), the opposite is true for many loads. Also, there is more financial reward for supplying spinning reserve than for supplying the other reserve services as a result of the higher spinning reserve prices. The LIPAedge program (LIPA's demand reduction program using Carrier ComfortChoice thermostats) provides an opportunity to test the use of responsive load for spinning reserve. With potentially 75 MW of spinning reserve capability already installed, this test program can also make an important contribution to the capacity needs of Long Island during the summer of 2003. Testing could also be done at ConEd ({approx}30 MW), SCE ({approx}15 MW), and/or SDG&E ({approx}15 MW). This paper is divided into six chapters. Chapter 2 discusses the contingency reserve ancillary services, their functions in supporting power system reliability, and their technical requirements. It also discusses the policy and tariff requirements and attempts to distinguish between ones that are genuinely necessary and ones that are artifacts of the technologies that were historically used to provide the services. Chapter 3 discusses how responsive load could provide contingency reserves (especially spinning reserve) for the power system. Chapter 4 specifically discusses the Carrier ComfortChoice responsive thermostat technology, the LIPAedge experience with that technology, and how the technology could be used to supply spinning reserve. Chapter 5 discusses a number of unresolved issues and suggests areas for further research. Chapter 6 offers conclusions and recommendations.

  20. PASSIVE DETECTION OF VEHICLE LOADING

    SciTech Connect (OSTI)

    Garrett, A.

    2012-01-03

    The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

  1. Load Forecast For use in Resource Adequacy

    E-Print Network [OSTI]

    forecast of 4) Calculate Hourly Load Allocation Factor s for each day for 2019 For use in RA analysis as a function ofthe load for electricity in the region as a function of cyclical, weather and economic variables

  2. Residential Load Management Program and Pilot 

    E-Print Network [OSTI]

    Haverlah, D.; Riordon, K.

    1994-01-01

    In 1986 LCRA embarked on residential load management to control peak summer loads. At that time, LCRA was considered a summer peaking utility, and residential air conditioning and water heating systems were selected for control. The program...

  3. Reference electrode for electrolytic cell

    DOE Patents [OSTI]

    Kessie, R.W.

    1988-07-28

    A reference electrode device is provided for a high temperature electrolytic cell used to electrolytically recover uranium from spent reactor fuel dissolved in an anode pool, the device having a glass tube to enclose the electrode and electrolyte and serve as a conductive membrane with the cell electrolyte, and an outer metal tube about the glass tube to serve as a shield and basket for any glass sections broken by handling of the tube to prevent their contact with the anode pool, the metal tube having perforations to provide access between the bulk of the cell electrolyte and glass membrane. 4 figs.

  4. Electrolytic cell with reference electrode

    DOE Patents [OSTI]

    Kessie, Robert W. (Naperville, IL)

    1989-01-01

    A reference electrode device is provided for a high temperature electrolytic cell used to electrolytically recover uranium from spent reactor fuel dissolved in an anode pool, the device having a glass tube to enclose the electrode and electrolyte and serve as a conductive membrane with the cell electrolyte, and an outer metal tube about the glass tube to serve as a shield and basket for any glass sections broken by handling of the tube to prevent their contact with the anode pool, the metal tube having perforations to provide access between the bulk of the cell electrolyte and glass membrane.

  5. PVWatts Version 1 Technical Reference

    SciTech Connect (OSTI)

    Dobos, A. P.

    2013-10-01

    The NREL PVWatts(TM) calculator is a web application developed by the National Renewable Energy Laboratory (NREL) that estimates the electricity production of a grid-connected photovoltaic system based on a few simple inputs. PVWatts combines a number of sub-models to predict overall system performance, and makes several hidden assumptions about performance parameters. This technical reference details the individual sub-models, documents assumptions and hidden parameters, and explains the sequence of calculations that yield the final system performance estimation.

  6. System and method employing a minimum distance and a load feature database to identify electric load types of different electric loads

    DOE Patents [OSTI]

    Lu, Bin; Yang, Yi; Sharma, Santosh K; Zambare, Prachi; Madane, Mayura A

    2014-12-23

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.

  7. Wind induced torsional loads on structures

    E-Print Network [OSTI]

    Kareem, Ahsan

    -level crosswind loading on a square cross-section building. Reinhold et al.4 instrumented a building model

  8. Plug Load Behavioral Change Demonstration Project

    SciTech Connect (OSTI)

    Metzger, I.; Kandt, A.; VanGeet, O.

    2011-08-01

    This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

  9. Modeling and Forecasting Electric Daily Peak Loads

    E-Print Network [OSTI]

    Abdel-Aal, Radwan E.

    for the same data. Two methods are described for forecasting daily peak loads up to one week ahead through, including generator unit commitment, hydro-thermal coordination, short-term maintenance, fuel allocation forecasting accuracies. STLF forecasting covers the daily peak load, total daily energy, and daily load curve

  10. Plutonium Immobilization Can Loading Preliminary Specifications

    SciTech Connect (OSTI)

    Kriikku, E.

    1998-11-25

    This report discusses the Plutonium Immobilization can loading preliminary equipment specifications and includes a process block diagram, process description, equipment list, preliminary equipment specifications, plan and elevation sketches, and some commercial catalogs. This report identifies loading pucks into cans and backfilling cans with helium as the top priority can loading development areas.

  11. Instantaneous Offloading of Transient Web Server Load

    E-Print Network [OSTI]

    Instantaneous Offloading of Transient Web Server Load Vsevolod V. Panteleenko and Vincent W. Freeh A modern web-hosting site is designed to handle load that is sometimes an order of magnitude greater than and performance study of the web booster architecture, which reduces web server load during peak periods. A web

  12. The accurate response prediction of hypersonic aircraft panels to the extreme loading environments of hypersonic flight is of immense importance to the U.S. Air Force.

    E-Print Network [OSTI]

    a representative hypersonic panel subjected to thermal, aerodynamic, and acoustic loads. The structural pressure and heating are accounted for with piston theory and Eckert's reference enthalpy method of a Panel Under Thermal, Aerodynamic, and Acoustic Loads Andrew Matney Advisor: Marc Mignolet April 21, 2014

  13. 1993 Pacific Northwest Loads and Resources Study.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    1993-12-01

    The Loads and Resources Study is presented in three documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The forecasted future electricity demands -- firm loads -- are subtracted from the projected capability of existing and {open_quotes}contracted for{close_quotes} resources to determine whether Bonneville Power Administration (BPA) and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, and additional conservation, contract purchases, or generating resources will be needed to meet load growth. The Pacific Northwest Loads and Resources Study analyzes the Pacific Northwest`s projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional power system, which includes loads and resource in addition to the Federal system. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA) produced by the Pacific Northwest Coordinating Group. This study presents the Federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 1994--95 through 2003--04.

  14. High loading uranium fuel plate

    DOE Patents [OSTI]

    Wiencek, Thomas C. (Bolingbrook, IL); Domagala, Robert F. (Indian Head Park, IL); Thresh, Henry R. (Palos Heights, IL)

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

  15. Automated fuel pin loading system

    DOE Patents [OSTI]

    Christiansen, David W. (Kennewick, WA); Brown, William F. (West Richland, WA); Steffen, Jim M. (Richland, WA)

    1985-01-01

    An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inserted as a batch prior to welding of end caps by one of two disclosed welding systems.

  16. INCREMENTAL COOLING LOAD DETERMINATION FOR PASSIVE DIRECT GAIN HEATING SYSTEMS

    E-Print Network [OSTI]

    Sullivan, Paul W.

    2013-01-01

    May 27-30, 1981 INCREMENTAL COOLING LOAD DETERMINATION FOR12048 May 1981 INCREMENTAL COOLING LOAD DETERMINATION FORfor increases in the building cooling load resulting from

  17. Investigation of residential central air conditioning load shapes in NEMS

    E-Print Network [OSTI]

    Hamachi LaCommare, Kristina; Marnay, Chris; Gumerman, Etan; Chan, Peter; Rosenquist, Greg; Osborn, Julie

    2002-01-01

    of Residential Central Air Conditioning Load Shapes in NEMSof Residential Central Air Conditioning Load Shapes in NEMSof Residential Central Air Conditioning Load Shapes in NEMS

  18. Optimal Load Management System for Aircraft Electric Power Distribution

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Nuzzo, Pierluigi; Iandola, Forrest; Kamgarpour, Maryam; Sangiovanni-Vincentelli, Alberto; Tomlin, Claire

    2014-01-01

    Optimal Load Management System for Aircraft Electric Poweris to develop an optimal load management system based on thescheme where a high-level load management system receives as

  19. ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM

    E-Print Network [OSTI]

    Krieg, B.

    2010-01-01

    Development Commission. Load Management in California. Staffon the Challenge of Load Management, Conservation Paper No.for Electric Utility Load Management. New York, New York:

  20. SNAP operating system reference manual

    SciTech Connect (OSTI)

    Sabuda, J.D.; Polito, J.; Walker, J.L.; Grant, F.H. III

    1982-03-01

    The SNAP Operating System (SOS) is a FORTRAN 77 program which provides assistance to the safeguards analyst who uses the Safeguards Automated Facility Evaluation (SAFE) and the Safeguards Network Analysis Procedure (SNAP) techniques. Features offered by SOS are a data base system for storing a library of SNAP applications, computer graphics representation of SNAP models, a computer graphics editor to develop and modify SNAP models, a SAFE-to-SNAP interface, automatic generation of SNAP input data, and a computer graphic post-processor for SNAP. The SOS Reference Manual provides detailed application information concerning SOS as well as a detailed discussion of all SOS components and their associated command input formats. SOS was developed for the US Nuclear Regulatory Commission's Office of Nuclear Regulatory Research and the US Naval Surface Weapons Center by Pritsker and Associates, Inc., under contract to Sandia National Laboratories.

  1. Investigating packaging effects on bandgap references

    E-Print Network [OSTI]

    Palakodety, Ravi (Ravi Kiran)

    2007-01-01

    This thesis investigates packaging effects on precision bandgap voltage references used in LTC switching regulators. Packaging stress causes a mean offset and room temperature distribution widening of the bandgap reference ...

  2. National Environmental Information Infrastructure Reference Architecture

    E-Print Network [OSTI]

    Greenslade, Diana

    National Environmental Information Infrastructure Reference Architecture Consultation Draft Contributing to the Australian Government National Plan for Environmental Information initiative #12;National Environmental Information Infrastructure Reference Architecture: Consultation Draft Environmental Information

  3. Sandia Energy - Reference Model Project (RMP)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Project (RMP) Home Stationary Power Energy Conversion Efficiency Water Power Reference Model Project (RMP) Reference Model Project (RMP)Tara Camacho-Lopez2015-05-11T21:01:36+00:00...

  4. Charting Future Directions for Reference Service

    E-Print Network [OSTI]

    Stratton, John M.; Devlin, Frances A.

    2011-10-18

    reference desks. Reference questions were coded using a taxonomy based on subject headings used to organize databases into broad categories, in addition to corresponding to professional schools within the University. Using our earlier study as a point...

  5. Low reflectance radio frequency load

    DOE Patents [OSTI]

    Ives, R. Lawrence; Mizuhara, Yosuke M

    2014-04-01

    A load for traveling microwave energy has an absorptive volume defined by cylindrical body enclosed by a first end cap and a second end cap. The first end cap has an aperture for the passage of an input waveguide with a rotating part that is coupled to a reflective mirror. The inner surfaces of the absorptive volume consist of a resistive material or are coated with a coating which absorbs a fraction of incident RF energy, and the remainder of the RF energy reflects. The angle of the reflector and end caps is selected such that reflected RF energy dissipates an increasing percentage of the remaining RF energy at each reflection, and the reflected RF energy which returns to the rotating mirror is directed to the back surface of the rotating reflector, and is not coupled to the input waveguide. Additionally, the reflector may have a surface which generates a more uniform power distribution function axially and laterally, to increase the power handling capability of the RF load. The input waveguide may be corrugated for HE11 mode input energy.

  6. Intel C++ Compiler User and Reference Guides

    E-Print Network [OSTI]

    Nikolic, Branislav K.

    Intel® C++ Compiler User and Reference Guides Document number: 304968-022US #12;Disclaimer) 2001, Hewlett-Packard Development Company, L.P. #12;#12;v Table of Contents Intel(R) C++ Compiler User and Reference Guides..............................................1 Intel® C++ Compiler User and Reference

  7. Reference Phase of Fresnel Zone Plates

    E-Print Network [OSTI]

    G. W. Webb

    2003-02-28

    The standard zone plate assumes that the shortest ray connecting a radiation source and a detection point has a phase of 0 deg thereby defining a reference phase. Here we examine the experimental consequences of varying this reference phase from 0 deg to 360 deg. It is concluded that reference phase is an intrinsic and useful property of zone plates.

  8. Bibliography of the Scripps Institution of Oceanography Reference Series 2001

    E-Print Network [OSTI]

    Criqui, Nan P.; Kuhns, Kittie K.

    2002-01-01

    Scripps Institution of Oceanography Reference Series 2001.SCRIPPS INSTITUTION OF OCEANOGRAPHY REFERENCE SERIES 01-01

  9. Preliminary Evaluation of Load Management for Electricity End Users 

    E-Print Network [OSTI]

    Collier, S. E.

    1984-01-01

    The planning, design and implementation of load management is complex and expensive. The results of a load management program are subject to numerous uncertainties related to load characteristics, power cost savings, load management costs...

  10. Load research manual. Volume 2. Fundamentals of implementing load research procedures

    SciTech Connect (OSTI)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  11. High voltage load resistor array

    DOE Patents [OSTI]

    Lehmann, Monty Ray (Smithfield, VA)

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  12. Technical Assistance to ISO's and Grid Operators For Loads Providing...

    Office of Environmental Management (EM)

    & Publications Loads Providing Ancillary Services: Review of International Experience Demand Response and Energy Storage Integration Study - Past Workshops Load Participation...

  13. NEUTRON WALL LOADING OF TOKAMAK REACTORS

    E-Print Network [OSTI]

    California at Los Angeles, University of

    GA­A23223 NEUTRON WALL LOADING OF TOKAMAK REACTORS by C.P.C. WONG OCTOBER 1999 #12;DISCLAIMER Government or any agency thereof. #12;GA­A23223 NEUTRON WALL LOADING OF TOKAMAK REACTORS by C.P.C. WONG by General Atomics IR&D Funds GA PROJECT 4437 OCTOBER 1999 #12;C.P.C. WONG NEUTRON WALL LOADING OF TOKAMAK

  14. Measured Peak Equipment Loads in Laboratories

    SciTech Connect (OSTI)

    Mathew, Paul A.

    2007-09-12

    This technical bulletin documents measured peak equipment load data from 39 laboratory spaces in nine buildings across five institutions. The purpose of these measurements was to obtain data on the actual peak loads in laboratories, which can be used to rightsize the design of HVAC systems in new laboratories. While any given laboratory may have unique loads and other design considerations, these results may be used as a 'sanity check' for design assumptions.

  15. History of Load Participation in ERCOT

    SciTech Connect (OSTI)

    Patterson, Mark

    2011-10-25

    Presentation on demand integration by ERCOT for a DOE Workshop. Covers history of load participation in ERCOT from 2002 to present.

  16. Decentralized customerlevel under frequency load shedding in...

    Open Energy Info (EERE)

    Decentralized customerlevel under frequency load shedding in Switzerland (Smart Grid Project) Jump to: navigation, search Project Name Decentralized customerlevel under frequency...

  17. Load Participation in Ancillary Services Workshop Report

    SciTech Connect (OSTI)

    Kirby, Brendan; O'Malley, Mark; Ma, Ookie; Cappers, Peter; Corbus, Dave; Kiliccote, Sila; Onar, Omer; Starke, Michael; Steinberg, Dan

    2011-10-25

    Developing load participation in ancillary services to the electric grid. Challenges: coordination among multiple entities, targeted R&D for market conditions and regulatory and policy environments.

  18. Building Technologies Office Load Control Strategies

    Broader source: Energy.gov [DOE]

    BTO researches and implements load control strategies, which support the Sustainable and Holistic IntegratioN of Energy storage and Solar PV (SHINES) FOA.

  19. FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH

    E-Print Network [OSTI]

    Lesieutre, Bernard

    2013-01-01

    of individual appliances. For off-grid applications, solarinappropriate load for an off-grid solar system. Increasedsolar systems in general, and off-grid solar systems in

  20. End-use load control for power system dynamic stability enhancement

    SciTech Connect (OSTI)

    Dagle, J.E.; Winiarski, D.W.; Donnelly, M.K.

    1997-02-01

    Faced with the prospect of increasing utilization of the transmission and distribution infrastructure without significant upgrade, the domestic electric power utility industry is investing heavily in technologies to improve network dynamic performance through a program loosely referred to as Flexible AC Transmission System (FACTS). Devices exploiting recent advances in power electronics are being installed in the power system to offset the need to construct new transmission lines. These devices collectively represent investment potential of several billion dollars over the next decade. A similar development, designed to curtail the peak loads and thus defer new transmission, distribution, and generation investment, falls under a category of technologies referred to as demand side management (DSM). A subset of broader conservation measures, DSM acts directly on the load to reduce peak consumption. DSM techniques include direct load control, in which a utility has the ability to curtail specific loads as conditions warrant. A novel approach has been conceived by Pacific Northwest National Laboratory (PNNL) to combine the objectives of FACTS and the technologies inherent in DSM to provide a distributed power system dynamic controller. This technology has the potential to dramatically offset major investments in FACTS devices by using direct load control to achieve dynamic stability objectives. The potential value of distributed versus centralized grid modulation has been examined by simulating the western power grid under extreme loading conditions. In these simulations, a scenario is analyzed in which active grid stabilization enables power imports into the southern California region to be increased several hundred megawatts beyond present limitations. Modeling results show distributed load control is up to 30 percent more effective than traditional centralized control schemes in achieving grid stability.

  1. Strategies for Controlling Plug Loads. A Tool for Reducing Plug Loads in Commercial Buildings

    SciTech Connect (OSTI)

    Torcellini, Paul; Bonnema, Eric; Sheppy, Michael; Pless, Shanti

    2015-09-01

    Plug loads are often not considered as part of the energy savings measures in Commercial Buildings; however, they can account for up to 50% of the energy used in the building. These loads are numerous and often scattered throughout a building. Some of these loads are purchased by the owner and some designed into the building or the tenant finishes for a space. This document provides a strategy and a tool for minimizing these loads.

  2. Internship Checklist Ready Reference C-3

    E-Print Network [OSTI]

    Internship Checklist Ready Reference C-3 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career Services Office

  3. Cover Letter Formula Ready Reference F-3

    E-Print Network [OSTI]

    Cover Letter Formula Ready Reference F-3 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career Services Office

  4. Letter of Refusal Ready Reference F-8

    E-Print Network [OSTI]

    Letter of Refusal Ready Reference F-8 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology Career

  5. Sample Withdrawal Letter Ready Reference F-11

    E-Print Network [OSTI]

    Sample Withdrawal Letter Ready Reference F-11 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology

  6. Sample Application Letter Ready Reference F-5

    E-Print Network [OSTI]

    Sample Application Letter Ready Reference F-5 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology

  7. Sample Networking Letter Ready Reference F-6

    E-Print Network [OSTI]

    Sample Networking Letter Ready Reference F-6 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology

  8. Sample Acceptance Letter Ready Reference F-10

    E-Print Network [OSTI]

    Sample Acceptance Letter Ready Reference F-10 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology

  9. Job Search Steps Ready Reference D-1

    E-Print Network [OSTI]

    Job Search Steps Ready Reference D-1 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career Services Office

  10. Preparing A Vita Ready Reference E-13

    E-Print Network [OSTI]

    Preparing A Vita Ready Reference E-13 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career Services Office

  11. FAQS Reference Guide – Facility Maintenance Management

    Office of Energy Efficiency and Renewable Energy (EERE)

    This reference guide addresses the competency statements in the April 2014 edition of DOE Standard DOE-STD-1181-2014, Facility Maintenance Management Functional Area Qualification Standard.

  12. FAQS Reference Guide – NNSA Package Certification Engineer

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the February 2009 edition of DOE-STD-1026-2009, NNSA Package Certification Engineer Functional Area Qualification Standard.

  13. FAQS Reference Guide – General Technical Base

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the December 2007 edition of DOE-STD-1146-2007, General Technical Base Functional Area Qualification Standard.

  14. EERE Program Management Quick Reference Guide

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Office of Energy Efficiency and Renewable Energy (EERE) Program Management Reference Guide. It provides an overall description of the EERE program management structure, defines...

  15. Reference Designs for Hydrogen Fueling Stations Webinar

    Broader source: Energy.gov [DOE]

    Access the recording and download the presentation slides from the Fuel Cell Technologies Office webinar "Reference Designs for Hydrogen Fueling Stations" held on October 13, 2015.

  16. Apparatus for loading a band saw blade

    DOE Patents [OSTI]

    Reeves, S.R.

    1990-03-20

    A band saw blade is loaded between pairs of guide wheels upon tensioning the blade by guiding the blade between pairs of spaced guide plates which define converging slots that converge toward the guide wheels. The approach is particularly useful in loading blades on underwater band saw machines used to cut radioactive materials. 2 figs.

  17. Nonparametric models for electricity load forecasting

    E-Print Network [OSTI]

    Genčve, Université de

    Electricity consumption is constantly evolving due to changes in people habits, technological innovations1 Nonparametric models for electricity load forecasting JANUARY 23, 2015 Yannig Goude, Vincent at University Paris-Sud 11 Orsay. His research interests are electricity load forecasting, more generally time

  18. Apparatus for loading a band saw blade

    DOE Patents [OSTI]

    Reeves, Steven R. (49 Williams Ave., West Valley, NY 14171)

    1990-01-01

    A band saw blade is loaded between pairs of guide wheels upon tensioning the blade by guiding the blade between pairs of spaced guide plates which define converging slots that converge toward the guide wheels. The approach is particularly useful in loading blades on underwater band saw machines used to cut radioactive materials.

  19. Harmonic Load Pull of High-Power Microwave Devices using Fundamental-Only Load Pull Tuners

    E-Print Network [OSTI]

    Popovic, Zoya

    Harmonic Load Pull of High-Power Microwave Devices using Fundamental-Only Load Pull Tuners John-frequency load pull tuners. Harmonic impedance control at the virtual drain is accomplished through the use the dramatic impact of varying 2nd harmonic termination. A 3rd harmonic termination is added to satisfy

  20. Using Utility Load Data to Estimate Demand for Space Cooling and Potential for Shiftable Loads

    SciTech Connect (OSTI)

    Denholm, P.; Ong, S.; Booten, C.

    2012-05-01

    This paper describes a simple method to estimate hourly cooling demand from historical utility load data. It compares total hourly demand to demand on cool days and compares these estimates of total cooling demand to previous regional and national estimates. Load profiles generated from this method may be used to estimate the potential for aggregated demand response or load shifting via cold storage.

  1. Generator Response to Load Variation The below table summarizes the way that load variation is

    E-Print Network [OSTI]

    McCalley, James D.

    1 Generator Response to Load Variation The below table summarizes the way that load variation is allocated to generators in a power system. In these notes, we derive the proximity effect, the inertial, constant impedance loads, and the network reduced to generator internal nodes. This expression was: { }00

  2. Equilibrium Configurations of Cantilever under Terminal Loads

    E-Print Network [OSTI]

    Milan Batista

    2013-03-27

    The paper provides an exact analytical solution for equilibrium configurations of cantilever rod subject to inclined force and torque acting on its free end. The solution is given in terms of Jacobi elliptical functions and illustrated by several numerical examples and several graphical presentations of shapes of deformed cantilever. Possible forms of cantilever underlying elastica are discussed in details and various simple formulas are given for calculation of characteristic dimensions of elastica. For the case when cantilever is subject only to applied force four load conditions are discussed: follower load problem, load determination problem, conservative load problem and rotational load problem. For all the cases the formulas or effective procedure for solution is given.

  3. Development of Reference Models and Design Tools (LCOE Models...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Development of Reference Models and Design Tools (LCOE Models) Development of Reference Models and Design Tools (LCOE Models) Development of Reference Models and Design Tools (LCOE...

  4. Federal Employee Training Desk Reference | Department of Energy

    Energy Savers [EERE]

    College of Learning and Workforce Development Federal Employee Training Desk Reference Federal Employee Training Desk Reference The DOE Federal Employee Training Desk Reference...

  5. Thermal Efficiency Optimization for Industrial Power Plants Under Load Fluctuations Using Fuzzy Logic 

    E-Print Network [OSTI]

    Steffenhagan, W.; de Sam Lazaro, A.

    1995-01-01

    to carry out the optimization. The results of this work will be published separately. 8. REFERENCES [1] Naccarino JR., Cheung RT., Briggs W., and Mayur N., Real-time monitoring, optimization and control of a hydroelectric generation complex. IEEE... OPTIMIZATION FOR INDUSTRIAL POWER PLANTS UNDER LOAD FLUCTUATIONS USING FUZZY LOGIC A. de Sam Lazaro and W. Steffenhagan, Department of Mechanical Engineering St Martin's College, Lacey WA 98503 1. INTRODUCTION The automation of the control to a power...

  6. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  7. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  8. OUTLOOK -MOBILE DEVICE ACCESS QUICK REFERENCE GUIDE

    E-Print Network [OSTI]

    Liley, David

    th OUTLOOK - MOBILE DEVICE ACCESS QUICK REFERENCE GUIDE Quick Reference Guide is designed to step you through the initial set up of your Outlook email account on your Mac. Note: If you're opening Microsoft Outlook 2011 for the first time, you will see the Welcome to Microsoft Outlook for Mac window

  9. OUTLOOK -MOBILE DEVICE ACCESS QUICK REFERENCE GUIDE

    E-Print Network [OSTI]

    Liley, David

    th OUTLOOK - MOBILE DEVICE ACCESS QUICK REFERENCE GUIDE This Quick Reference Guide is designed to step you through the setup of your Outlook email account on your mobile device. When to use this Guide is Outlook. NOTE: After you have set up your account you must remove your old GWSync account ITS

  10. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  11. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  12. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  13. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  14. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  15. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  16. Intel Fortran Compiler User and Reference Guides

    E-Print Network [OSTI]

    Nikolic, Branislav K.

    Intel® Fortran Compiler User and Reference Guides Document number: 304970-005US #12;Disclaimer) 2001, Hewlett-Packard Development Company, L.P. #12;#12;v Table of Contents Intel(R) Fortran Compiler User and Reference Guides.........................................1 Intel® Fortran Compiler User

  17. IEEE TRANSACTIONS ON SMART GRID, VOL. 1, NO. 2, SEPTEMBER 2010 213 Automated Load Curve Data Cleansing

    E-Print Network [OSTI]

    Wang, Ke

    Cleansing in Power Systems Jiyi Chen, Wenyuan Li, Fellow, IEEE, Adriel Lau, Jiguo Cao, and Ke Wang, Senior quality. I. INTRODUCTION A. Background LOAD CURVE data refers to the electric energy consump- tion is the "heart- beat" of electricity systems and is one of several most important data sets collected

  18. UTILITY-SCALE SOLAR LOAD CONTROL Richard Perez, ASRC

    E-Print Network [OSTI]

    Perez, Richard R.

    was initially devised to function with user-sited PV installations to maximize demand reduction. An efficient load reduction (middle). By shedding load in response to PV output and load requirements the SLC load control (DLC) enhancement. The aggregate of direct load controlled customers constitute a reliable

  19. Synthesis of polyoxometalate-loaded epoxy composites

    DOE Patents [OSTI]

    Anderson, Benjamin J

    2014-10-07

    The synthesis of a polyoxometalate-loaded epoxy uses a one-step cure by applying an external stimulus to release the acid from the polyoxometalate and thereby catalyze the cure reaction of the epoxy resin. Such polyoxometalate-loaded epoxy composites afford the cured epoxy unique properties imparted by the intrinsic properties of the polyoxometalate. For example, polyoxometalate-loaded epoxy composites can be used as corrosion resistant epoxy coatings, for encapsulation of electronics with improved dielectric properties, and for structural applications with improved mechanical properties.

  20. Load apparatus and method for bolt-loaded compact tension test specimen

    DOE Patents [OSTI]

    Buescher, B.J. Jr.; Lloyd, W.R.; Ward, M.B.; Epstein, J.S.

    1997-02-04

    A bolt-loaded compact tension test specimen load apparatus includes: (a) a body having first and second opposing longitudinal ends, the first end comprising an externally threaded portion sized to be threadedly received within the test specimen threaded opening; (b) a longitudinal loading rod having first and second opposing longitudinal ends, the loading rod being slidably received in a longitudinal direction within the body internally through the externally threaded portion and slidably extending longitudinally outward of the body first longitudinal end; (c) a force sensitive transducer slidably received within the body and positioned to engage relative to the loading rod second longitudinal end; and (d) a loading bolt threadedly received relative to the body, the loading bolt having a bearing end surface and being positioned to bear against the transducer to forcibly sandwich the transducer between the loading bolt and loading rod. Also disclosed is a method of in situ determining applied force during crack propagation in a bolt-loaded compact tension test specimen. 6 figs.

  1. Final Project Report Load Modeling Transmission Research

    SciTech Connect (OSTI)

    Lesieutre, Bernard; Bravo, Richard; Yinger, Robert; Chassin, Dave; Huang, Henry; Lu, Ning; Hiskens, Ian; Venkataramanan, Giri

    2012-03-31

    The research presented in this report primarily focuses on improving power system load models to better represent their impact on system behavior. The previous standard load model fails to capture the delayed voltage recovery events that are observed in the Southwest and elsewhere. These events are attributed to stalled air conditioner units after a fault. To gain a better understanding of their role in these events and to guide modeling efforts, typical air conditioner units were testing in laboratories. Using data obtained from these extensive tests, new load models were developed to match air conditioner behavior. An air conditioner model is incorporated in the new WECC composite load model. These models are used in dynamic studies of the West and can impact power transfer limits for California. Unit-level and systemlevel solutions are proposed as potential solutions to the delayed voltage recovery problem.

  2. FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH

    E-Print Network [OSTI]

    Lesieutre, Bernard

    2013-01-01

    model.   3.0 PV System Modeling Issues When modeling the PV systems in the electric  power electric grid.   4.0 Load Composition Data Tool 4.1. Introduction A power system model 

  3. Impact of load type on microgrid stability

    E-Print Network [OSTI]

    Monnin, Jared P

    2012-01-01

    Microgrids show great promise as a means of integrating distributed generation sources into the public grid distribution system. In order to provide uninterrupted,high quality power to local loads, microgrids must have the ...

  4. Determining Electric Motor Load and Efficiency

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    DETERMINING ELECTRIC MOTOR LOAD AND EFFICIENCY Most likely your operation's motors account for a large part of your monthly electric bill. Far too often motors are mismatched-or...

  5. S-Band Loads for SLAC Linac

    SciTech Connect (OSTI)

    Krasnykh, A.; Decker, F.-J.; /SLAC; LeClair, R.; /INTA Technologies, Santa Clara

    2012-08-28

    The S-Band loads on the current SLAC linac RF system were designed, in some cases, 40+ years ago to terminate 2-3 MW peak power into a thin layer of coated Kanthal material as the high power absorber [1]. The technology of the load design was based on a flame-sprayed Kanthal wire method onto a base material. During SLAC linac upgrades, the 24 MW peak klystrons were replaced by 5045 klystrons with 65+ MW peak output power. Additionally, SLED cavities were introduced and as a result, the peak power in the current RF setup has increased up to 240 MW peak. The problem of reliable RF peak power termination and RF load lifetime required a careful study and adequate solution. Results of our studies and three designs of S-Band RF load for the present SLAC RF linac system is discussed. These designs are based on the use of low conductivity materials.

  6. Largest Ice-Bank Promotes Load Management 

    E-Print Network [OSTI]

    Brarmann, G. L.

    1983-01-01

    conservation measures were incorporated in the design of the new research facility, the ice-bank system has been the most cost-effective of the load management projects at Union Oil....

  7. FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH

    E-Print Network [OSTI]

    Lesieutre, Bernard

    2013-01-01

    to voltage and frequency  disturbances by offering a much to voltage and frequency  disturbances by offering a much disturbances is that modeling the voltage sensitivity of the load is far more important than the  frequency 

  8. Radiation load to the SNAP CCD

    SciTech Connect (OSTI)

    N. V. Mokhov, I. L. Rakhno and S. I. Striganov

    2003-08-14

    Results of an express Monte Carlo analysis with the MARS14 code of radiation load to the CCD optical detectors in the Supernova Acceleration Project (SNAP) mission presented for realistic radiation environment over the satellite orbit.

  9. Monitoring of Electrical End-Use Loads in Commercial Buildings 

    E-Print Network [OSTI]

    Martinez, M.; Alereza, T.; Mort, D.

    1988-01-01

    custom-designed to facilitate collection and validation of the end-use load data. For example, the Load Profile Viewer is a PC-based software program for reviewing and validating the end-use load data....

  10. Harmonic approaches to non-intrusive load diagnostics

    E-Print Network [OSTI]

    Fuller, Ashley E. (Ashley Eliot)

    2008-01-01

    The Non-Intrusive Load Monitor (NILM) is a system that monitors, records and processes voltage and current measurements to establish the operating characteristics of individual loads on a load center from a single aggregate ...

  11. A three phase load flow algorithm for Shipboard Power Systems 

    E-Print Network [OSTI]

    Medina-Calder?on, M?onica M

    2003-01-01

    -Seidel and/or Newton Raphson techniques, were primarily developed for transmission system analysis. Distribution load flow analysis must incorporate its unique characteristics such as unbalanced loads, distributed loads, radial network structure, and one...

  12. Steady state load models for power system analysis 

    E-Print Network [OSTI]

    Cresswell, Charles

    2009-01-01

    The last full review of load models used for power system studies occurred in the 1980s. Since then, new types of loads have been introduced and system load mix has changed considerably. The examples of newly introduced ...

  13. Gearbox Reliability Collaborative (GRC) Description and Loading

    SciTech Connect (OSTI)

    Oyague, F.

    2011-11-01

    This document describes simulated turbine load cases in accordance to the IEC 61400-1 Ed.3 standard, which is representative of the typical wind turbine design process. The information presented herein is intended to provide a broad understanding of the gearbox reliability collaborative 750kW drivetrain and turbine configuration. In addition, fatigue and ultimate strength drivetrain loads resulting from simulations are presented. This information provides the bases for the analytical work of the gearbox reliability collaborative effort.

  14. LIBRARY AND INFORMATION SERVICES DIVISION Current References

    E-Print Network [OSTI]

    LIBRARY AND INFORMATION SERVICES DIVISION Current References (92 -1) ,..... .. , ... ........,., ECOSYSTEMS OF THE FLORIDA KEYS · A Bibliography U. S. DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration National Environmental Satellite, Data, and Information Service National Oceanographic Data Center

  15. Salary Negotiation Ready ReferenceH-3

    E-Print Network [OSTI]

    Salary Negotiation Ready ReferenceH-3 College of Engineering, Architecture & Technology Career" salary on the top end of your range. Although this range may appear high because it is created from

  16. Writing Career Objectives Ready Reference E-5

    E-Print Network [OSTI]

    Writing Career Objectives Ready Reference E-5 College of Engineering, Architecture & Technology in pharmaceutical research" #12;Oklahoma State University College of Engineering, Architecture & Technology Career your practical skills. Examples: -"A position in a large, high tech organization requiring network

  17. Generic Argillite/Shale Disposal Reference Case

    E-Print Network [OSTI]

    Zheng, Liange

    2014-01-01

    S. and K.S. Johnson, (1984). Shale and other argillaceousand R. T. Cygan, (2010). Shale Disposal of U.S. High-LevelDC. Generic Argillite/Shale Disposal Reference Case August

  18. Archive Reference Buildings by Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  19. New Construction Commercial Reference Buildings — Archive

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  20. Emergency Responder Radioactive Material Quick Reference Sheet

    Broader source: Energy.gov [DOE]

    This job aid is a quick reference to assist emergency responders in identifying preliminary safety precautions that should be taken during the initial response phase after arrival at the scene of...

  1. FAQS Reference Guide – Civil/ Structural Engineering

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the March 2004 edition of DOE-STD-1182-2004, Civil/Structural Engineering Functional Area Qualification Standard.

  2. FAQS Reference Guide – Safety Software Quality Assurance

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the (March 2011) edition of DOE-STD-1172-2011, Safety Software Quality Assurance Functional Area Qualification Standard.

  3. Pronominal System and Reference in Pulaar

    E-Print Network [OSTI]

    Ba, Ibrahima

    2015-12-20

    This paper examines pronominal reference and the long-distance anaphor in Pulaar, a West African language spoken from Senegal to Niger and Cameroon. I am focusing on Toore, a dialect of Pulaar spoken in southern Senegal. ...

  4. Clause chaining, switch reference and coordination

    E-Print Network [OSTI]

    Nonato, Rafael

    2014-01-01

    In this thesis I ponder over a constellation of phenomena that revolve around switch reference and coordination, drawing mainly on their instantiation in Kisedje (Je, Brazil). I start by investigating Klsedje's case system. ...

  5. Precision Micropower, Low Dropout Voltage References

    E-Print Network [OSTI]

    Berns, Hans-Gerd

    series references are specified over the extended industrial temperature range (-40°C to +85°C) with typical performance specifications over -40°C to +125°C for applications, such as automotive. All

  6. Archive Reference Buildings by Building Type: Supermarket

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  7. Javarifier : inference of reference immutability in Java

    E-Print Network [OSTI]

    Quinonez, Jamie

    2008-01-01

    Javari is an extension of Java that supports reference immutability constraints. Programmers write Javari type qualifiers, such as the readonly type qualifier, in their programs, and the Javari typechecker detects mutation ...

  8. Generating and interpreting referring expressions in context

    E-Print Network [OSTI]

    Smith, Dustin Arthur

    2013-01-01

    Referring expressions with vague and ambiguous modifiers, such as "a quick visit" and "the big meeting," are difficult for computers to interpret because their meanings are defined in part by context. For the hearer to ...

  9. Integrating Referring and Informing in NP Planning 

    E-Print Network [OSTI]

    O'Donnell, Michael; Knott, Alistair; Hitzeman, Janet; Cheng, Hua

    Two of the functions of an NP are to refer (identify a particular entity) and to inform (provide new information about an entity). While many NPs may serve only one of these functions, some NPs conflate the functions, ...

  10. Population Reference Bureau Kenneth W. Wachter

    E-Print Network [OSTI]

    Wachter, Kenneth W.

    -Recapture Estimates 2. Logistic Regression for Stratum Rates 3. Synthetic Estimation for Small Areas KWW ­ p. 14/2 #12,000 households · American Community Survey: Reverse Record Check KWW ­ p. 20/2 #12;References Bell, Robert and M

  11. An expectation model of referring expressions

    E-Print Network [OSTI]

    Krćmer, John, Ph. D. Massachusetts Institute of Technology

    2010-01-01

    This thesis introduces EMRE, an expectation-based model of referring expressions. EMRE is proposed as a model of non-syntactic dependencies - in particular, discourse-level semantic dependencies that bridge sentence gaps. ...

  12. Load cell having strain gauges of arbitrary location

    DOE Patents [OSTI]

    Spletzer, Barry (Albuquerque, NM)

    2007-03-13

    A load cell utilizes a plurality of strain gauges mounted upon the load cell body such that there are six independent load-strain relations. Load is determined by applying the inverse of a load-strain sensitivity matrix to a measured strain vector. The sensitivity matrix is determined by performing a multivariate regression technique on a set of known loads correlated to the resulting strains. Temperature compensation is achieved by configuring the strain gauges as co-located orthogonal pairs.

  13. Quantum communication, reference frames and gauge theory

    E-Print Network [OSTI]

    S. J. van Enk

    2006-04-26

    We consider quantum communication in the case that the communicating parties not only do not share a reference frame but use imperfect quantum communication channels, in that each channel applies some fixed but unknown unitary rotation to each qubit. We discuss similarities and differences between reference frames within that quantum communication model and gauge fields in gauge theory. We generalize the concept of refbits and analyze various quantum communication protocols within the communication model.

  14. "Analysis of SOFCs using reference electrodes?

    SciTech Connect (OSTI)

    Finklea, Harry; Chen,Xiaoke; Gerdes,Kirk; Pakalapati, Suryanarayana; Celik, Ismail

    2013-07-01

    Reference electrodes are frequently applied to isolate the performance of one electrode in a solid oxide fuel cell. However, reference electrode simulations raise doubt to veracity of data collected using reference electrodes. The simulations predict that the reported performance for the one electrode will frequently contain performance of both electrodes. Nonetheless, recent reports persistently treat data so collected as ideally isolated. This work confirms the predictions of the reference electrode simulations on two SOFC designs, and to provides a method of validating the data measured in the 3-electrode configuration. Validation is based on the assumption that a change in gas composition to one electrode does not affect the impedance of the other electrode at open circuit voltage. This assumption is supported by a full physics simulation of the SOFC. Three configurations of reference electrode and cell design are experimentally examined using various gas flows and two temperatures. Impedance data are subjected to deconvolution analysis and equivalent circuit fitting and approximate polarization resistances of the cathode and anode are determined. The results demonstrate that the utility of reference electrodes is limited and often wholly inappropriate. Reported impedances and single electrode polarization values must be scrutinized on this basis.

  15. Generic disposal concepts and thermal load management for larger...

    Office of Scientific and Technical Information (OSTI)

    Generic disposal concepts and thermal load management for larger waste packages. Citation Details In-Document Search Title: Generic disposal concepts and thermal load management...

  16. Healthcare Energy: Spotlight on Lighting and Other Electric Loads...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Lighting and Other Electric Loads Healthcare Energy: Spotlight on Lighting and Other Electric Loads Compact fluorescent, light-emitting diode, and energy-saving incandescent light...

  17. Beam Loading by Distributed Injection of Electrons in a Plasma...

    Office of Scientific and Technical Information (OSTI)

    Journal Article: Beam Loading by Distributed Injection of Electrons in a Plasma Wakefield Accelerator Citation Details In-Document Search Title: Beam Loading by Distributed...

  18. Minimized Space Conditioning Distribution Strategy for Low-load...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Minimized Space Conditioning Distribution Strategy for Low-load Homes Minimized Space Conditioning Distribution Strategy for Low-load Homes This presentation was given at the...

  19. Nanosegregated Cathode Catalysts with Ultra-Low Platinum Loading...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Nanosegregated Cathode Catalysts with Ultra-Low Platinum Loading Nanosegregated Cathode Catalysts with Ultra-Low Platinum Loading Presented at the Department of Energy Fuel Cell...

  20. Loads Providing Ancillary Services: Review of International Experience...

    Energy Savers [EERE]

    have been relaxed as third party load aggregators have developed and installed lower-cost communications equipment. These load aggregators targeted customers with small...

  1. Local Soot Loading Distribution in Cordierite Diesel Particulate...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Local Soot Loading Distribution in Cordierite Diesel Particulate Filters by Dynamic Neutron Radiography Local Soot Loading Distribution in Cordierite Diesel Particulate Filters by...

  2. Locality Aware Dynamic Load Management for Massively Multiplayer Games

    E-Print Network [OSTI]

    Amza, Cristiana

    Locality Aware Dynamic Load Management for Massively Multiplayer Games Jin Chen Department with a dynamic load management algorithm enables us to better handle transient crowding by adaptively dispersing

  3. The Development of a Small Engine Based Accelerated Ash Loading...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Accelerated Ash Loading Protocol The Development of a Small Engine Based Accelerated Ash Loading Protocol Presentation given at DEER 2006, August 20-24, 2006, Detroit, Michigan....

  4. Development of an Accelerated Ash-Loading Protocol for Diesel...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    an Accelerated Ash-Loading Protocol for Diesel Particulate Filters Development of an Accelerated Ash-Loading Protocol for Diesel Particulate Filters Poster presentation at the 2007...

  5. Used Nuclear Fuel Loading and Structural Performance Under Normal...

    Energy Savers [EERE]

    Used Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Modeling, Simulation and Experimental Integration RD&D Plan Used Nuclear Fuel Loading...

  6. Load controller and method to enhance effective capacity of a photovoltaic power supply using a dynamically determined expected peak loading

    DOE Patents [OSTI]

    Perez, Richard

    2005-05-03

    A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply.

  7. Plug Load Energy Analysis: The Role of Plug Loads in LEED Certification

    E-Print Network [OSTI]

    Fuertes, Gwen; Schiavon, Stefano

    2013-01-01

    Energy performance of LEED® for new construction buildings,The Role of Plug Loads in LEED Certification Gwen FuertesGreen Building Council for LEED certification. The study

  8. A comparison of measured wind park load histories with the WISPER and WISPERX load spectra

    SciTech Connect (OSTI)

    Kelley, N.D.

    1995-01-01

    The blade-loading histories from two adjacent Micon 65/13 wind turbines are compared with the variable-amplitude test-loading histories known as the WISPER and WISPERX spectra. These standardized loading sequences were developed from blade flapwise load histories taken from nine different horizontal-axis wind turbines operating under a wide range of conditions in Europe. The subject turbines covered a broad spectrum of rotor diameters, materials, and operating environments. The final loading sequences were developed as a joint effort of thirteen different European organizations. The goal was to develop a meaningful loading standard for horizontal-axis wind turbine blades that represents common interaction effects seen in service. In 1990, NREL made extensive load measurements on two adjacent Micon 65/13 wind turbines in simultaneous operation in the very turbulent environment of a large wind park. Further, before and during the collection of the loads data, comprehensive measurements of the statistics of the turbulent environment were obtained at both the turbines under test and at two other locations within the park. The trend to larger but lighter wind turbine structures has made an understanding of the expected lifetime loading history of paramount importance. Experience in the US has shown that the turbulence-induced loads associated with multi-row wind parks in general are much more severe than for turbines operating individually or within widely spaced environments. Multi-row wind parks are much more common in the US than in Europe. In this paper we report on our results in applying the methodology utilized to develop the WISPER and WISPERX standardized loading sequences using the available data from the Micon turbines. While the intended purpose of the WISPER sequences were not to represent a specific operating environment, we believe the exercise is useful, especially when a turbine design is likely to be installed in a multi-row wind park.

  9. 2006 Pacific Northwest Loads and Resources Study.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    2006-03-01

    The Pacific Northwest Loads and Resources Study (White Book), which is published annually by the Bonneville Power Administration (BPA), establishes one of the planning bases for supplying electricity to customers. The White Book contains projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. The White Book also contains information obtained from formalized resource planning reports and data submittals including those from individual utilities, the Northwest Power and Conservation Council (Council), and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for determining BPA revenues, although the database that generates the data for the White Book analysis contributes to the development of BPA's inventory and ratemaking processes. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions that include expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. The load resource balance of both the Federal system and the region is determined by comparing resource availability to an expected level of total retail electricity consumption. Resources include projected energy capability plus contract purchases. Loads include a forecast of retail obligations plus contract obligations. Surplus energy is available when resources are greater than loads. This surplus energy could be marketed to increase revenues. Energy deficits occur when resources are less than loads. These energy deficits will be met by any combination of the following: better-than-critical water conditions, demand-side management and conservation programs, permanent loss of loads due to economic conditions or closures, additional contract purchases, and/or the addition of new generating resources. This study incorporates information on Pacific Northwest (PNW) regional retail loads, contract obligations, and contract resources. This loads and resources analysis simulates the operation of the power system in the PNW. The simulated hydro operation incorporates plant characteristics, streamflows, and non-power requirements from the current Pacific Northwest Coordination Agreement (PNCA). Additional resource capability estimates were provided by BPA, PNW Federal agency, public agency, cooperative, U.S. Bureau of Reclamation (USBR), and investor-owned utility (IOU) customers furnished through annual PNUCC data submittals for 2005 and/or direct submittals to BPA. The 2006 White Book is presented in two documents: (1) this summary document of Federal system and PNW region loads and resources, and (2) a technical appendix which presents regional loads, grouped by major PNW utility categories, and detailed contract and resource information. The technical appendix is available only in electronic form. Individual customer information for marketer contracts is not detailed due to confidentiality agreements. The 2006 White Book analysis updates the 2004 White Book. This analysis shows projections of the Federal system and region's yearly average annual energy consumption and resource availability for the study period, OY 2007-2016. The study also presents projections of Federal system and region expected 1-hour monthly peak demand, monthly energy demand, monthly 1-hour peak generating capability, and monthly energy generation for OY 2007, 2011, and 2016. BPA is investigating a new approach in capacity planning depicting the monthly Federal system 120-hour peak generating capability and 120-hour peak surplus/deficit for OY 2007, 2011, and 2016. This document analyzes the PNW's projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency;

  10. Low-Load Space Conditioning Needs Assessment

    SciTech Connect (OSTI)

    Puttagunta, Srikanth

    2015-05-01

    With limited low-load options in the HVAC market, many new-construction housing units are being fitted with oversized equipment - thus facing penalties in system efficiency, comfort, and cost. To bridge the gap between currently available HVAC equipment and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of multifamily buildings and single-family homes market needs. Over the past decade, Steven Winter Associates, Inc. (SWA) has provided certification and consulting services on hundreds of housing projects and has accrued a large pool of data. CARB compiled and analyzed these data to see what the thermal load ranges are in various multifamily apartments and attached single-family home types (duplex and townhouse). In total, design loads from 941 dwellings from SWA's recent multifamily and attached single-family work across the Northeast and Mid-Atlantic were analyzed. Information on the dwelling characteristics, design loads, and the specifications of installed mechanical equipment were analyzed to determine any trends that exist within the dataset.

  11. Modality Effects on Cognitive Load and Performance in High-Load Information Presentation

    E-Print Network [OSTI]

    Theune, Mariët

    INTRODUCTION Intelligent human-computer interfaces are often multimodal, i.e. the human-computer communications into the modality planning procedure for systems that support high-load human-computer interaction. Author Keywords-load information presenta- tion scenario. Mainly based on modality-related psychology theories, we selected five

  12. Reconstruction of a wind turbine's endured load spectrum using a short-time load measurement

    E-Print Network [OSTI]

    Berlin,Technische Universität

    Reconstruction of a wind turbine's endured load spectrum using a short-time load measurement Abstract Wind turbines (WT) are normally designed for a service life (SL) of 20 years. In Germany, over safety. 1 Introduction A wind turbine (WT) is normally designed, tested and certified for a design life

  13. Dimeric Drug Polymeric Nanoparticles with Exceptionally High Drug Loading and Quantitative Loading Efficiency

    E-Print Network [OSTI]

    Cheng, Jianjun

    Dimeric Drug Polymeric Nanoparticles with Exceptionally High Drug Loading and Quantitative LoadingChampaign, Urbana, Illinois 61801, United States Key Laboratory of Smart Drug Delivery, Ministry of Education-molecule drugs in hydrophobic polymers or amphiphilic copolymers has been extensively used for preparing

  14. Load attenuating passively adaptive wind turbine blade

    DOE Patents [OSTI]

    Veers, Paul S.; Lobitz, Donald W.

    2003-01-07

    A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.

  15. Load attenuating passively adaptive wind turbine blade

    DOE Patents [OSTI]

    Veers, Paul S. (Albuquerque, NM); Lobitz, Donald W. (Albuquerque, NM)

    2003-01-01

    A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.

  16. Enhanced Magnetic Trap Loading for Atomic Strontium

    E-Print Network [OSTI]

    Barker, D S; Pisenti, N C; Campbell, G K

    2015-01-01

    We report on a technique to improve the continuous loading of atomic strontium into a magnetic trap from a Magneto-Optical Trap (MOT). This is achieved by adding a depumping laser tuned to the 3P1 to 3S1 (688-nm) transition. The depumping laser increases atom number in the magnetic trap and subsequent cooling stages by up to 65 % for the bosonic isotopes and up to 30 % for the fermionic isotope of strontium. We optimize this trap loading strategy with respect to the 688-nm laser detuning, intensity, and beam size. To understand the results, we develop a one-dimensional rate equation model of the system, which is in good agreement with the data. We discuss the use of other transitions in strontium for accelerated trap loading and the application of the technique to other alkaline-earth-like atoms.

  17. PARAMETRIC MODELS FOR ESTIMATING WIND TURBINE FATIGUE LOADS FOR DESIGN

    E-Print Network [OSTI]

    Sweetman, Bert

    1 PARAMETRIC MODELS FOR ESTIMATING WIND TURBINE FATIGUE LOADS FOR DESIGN Lance Manuel1 Paul S-4020 ABSTRACT International standards for wind turbine certification depend on finding long-term fatigue load loads. #12;2 INTRODUCTION Design constraints for wind turbine structures fall into either extreme load

  18. AIAA-2001-0044 Extreme Load Estimation for Wind Turbines

    E-Print Network [OSTI]

    AIAA-2001-0044 Extreme Load Estimation for Wind Turbines: Issues and Opportunities for Improved design load estimation procedures for wind turbines often do not accurately treat the statistical nature of loads. Current practice for wind turbine load analysis is reviewed. The authors

  19. "Load Management Systems for Component-based Middleware"

    E-Print Network [OSTI]

    Murphy, John

    "Load Management Systems for Component-based Middleware" Octavian Ciuhandu, B.E. Masters Management Services Characteristics . . . . . 26 3.3.2 Load Management Services Classification . . . . . . 28 3.3.3 Load Management Services Requirements . . . . . 30 3.3.4 Load Management Services Components

  20. References - DOE Directives, Delegations, and Requirements

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProtonAbout Us HanfordReference MaterialsReference Shelf

  1. Intelligent electrical outlet for collective load control

    DOE Patents [OSTI]

    Lentine, Anthony L.; Ford, Justin R.; Spires, Shannon V.; Goldsmith, Steven Y.

    2015-10-27

    Various technologies described herein pertain to an electrical outlet that autonomously manages loads in a microgrid. The electrical outlet can provide autonomous load control in response to variations in electrical power generation supply in the microgrid. The electrical outlet includes a receptacle, a sensor operably coupled to the receptacle, and an actuator configured to selectively actuate the receptacle. The sensor measures electrical parameters at the receptacle. Further, a processor autonomously controls the actuator based at least in part on the electrical parameters measured at the receptacle, electrical parameters from one or more disparate electrical outlets in the microgrid, and a supply of generated electric power in the microgrid at a given time.

  2. Intelligent electrical outlet for collective load control

    DOE Patents [OSTI]

    Lentine, Anthony L; Ford, Justin R; Spires, Shannon V; Goldsmith, Steven Y

    2015-11-05

    Various technologies described herein pertain to an electrical outlet that autonomously manages loads in a microgrid. The electrical outlet can provide autonomous load control in response to variations in electrical power generation supply in the microgrid. The electrical outlet includes a receptacle, a sensor operably coupled to the receptacle, and an actuator configured to selectively actuate the receptacle. The sensor measures electrical parameters at the receptacle. Further, a processor autonomously controls the actuator based at least in part on the electrical parameters measured at the receptacle, electrical parameters from one or more disparate electrical outlets in the microgrid, and a supply of generated electric power in the microgrid at a given time.

  3. Demand-Side Response from Industrial Loads

    SciTech Connect (OSTI)

    Starke, Michael R; Alkadi, Nasr E; Letto, Daryl; Johnson, Brandon; Dowling, Kevin; George, Raoule; Khan, Saqib

    2013-01-01

    Through a research study funded by the Department of Energy, Smart Grid solutions company ENBALA Power Networks along with the Oak Ridge National Laboratory (ORNL) have geospatially quantified the potential flexibility within industrial loads to leverage their inherent process storage to help support the management of the electricity grid. The study found that there is an excess of 12 GW of demand-side load flexibility available in a select list of top industrial facilities in the United States. Future studies will expand on this quantity of flexibility as more in-depth analysis of different industries is conducted and demonstrations are completed.

  4. NIST Standard Reference Database 23 NIST Reference Fluid Thermodynamic and Transport Properties--

    E-Print Network [OSTI]

    measurements and models we have taken from the literature, and without which this database would be much#12;NIST Standard Reference Database 23 NIST Reference Fluid Thermodynamic and Transport Properties (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data

  5. Terms of Reference Information Security Group

    E-Print Network [OSTI]

    Haase, Markus

    Terms of Reference Information Security Group Version 3.1 8 March 2011 © University of Leeds 2011 Security Group Information Security Management 3.1 (8/3/11) Page 2 of 4 Document Control Owner: Kevin Darley, IT Security Co-ordinator, Information Systems Services, University of Leeds Source Location: V

  6. Risk Management Steering Committee Terms of Reference

    E-Print Network [OSTI]

    Victoria, University of

    Risk Management Steering Committee Terms of Reference October 2009 1.0 Purpose The purposes Facilities Management Risk and Insurance Analyst Associate Vice-President Human Resources Administrative of the Steering Committee are: a) to follow a continuous process to understand and communicate risk from

  7. The Behavioral Interview Ready Reference G-7

    E-Print Network [OSTI]

    The Behavioral Interview Ready Reference G-7 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology in technical and high tech industries within the last 10 years. Behavioral interviews are designed to focus

  8. Questioning Yourself Ready Reference B-2

    E-Print Network [OSTI]

    Questioning Yourself Ready Reference B-2 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career Services Office set my own hours? Do I thrive in a high-stress atmosphere, or would I prefer something a bit more

  9. INVESTIGATION Construction of Reference Chromosome-Scale

    E-Print Network [OSTI]

    Douches, David S.

    INVESTIGATION Construction of Reference Chromosome-Scale Pseudomolecules for Potato: Integrating was genotyped with several types of molecular genetic markers to construct a new ~936 cM linkage map comprising and orientation within the pseudo- molecules are closely collinear with independently constructed high density

  10. Quick-Reference Guide to Optimization with

    E-Print Network [OSTI]

    Nikolic, Branislav K.

    Quick-Reference Guide to Optimization with Intel® Compilers version 11 For IA-32 processors, Intel, you may want to check correctness of your application by building it without optimization using /Od (-O0). In this compiler version, all optimization levels assume support for the SSE2 instruction set

  11. Previous Up Next Article From References: 0

    E-Print Network [OSTI]

    Ottino, Julio M.

    (e.g. laminar) fluid flow. Two decades of interdisciplinary studies in this line of investigationPrevious Up Next Article Citations From References: 0 From Reviews: 0 MR2265644 (Review) 37N10 (37D in applications: micro to macro, fluids to solids. Cambridge Monographs on Applied and Computational Mathematics

  12. Xyce parallel electronic simulator : reference guide.

    SciTech Connect (OSTI)

    Mei, Ting; Rankin, Eric Lamont; Thornquist, Heidi K.; Santarelli, Keith R.; Fixel, Deborah A.; Coffey, Todd Stirling; Russo, Thomas V.; Schiek, Richard Louis; Warrender, Christina E.; Keiter, Eric Richard; Pawlowski, Roger Patrick

    2011-05-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide. The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. It is targeted specifically to run on large-scale parallel computing platforms but also runs well on a variety of architectures including single processor workstations. It also aims to support a variety of devices and models specific to Sandia needs. This document is intended to complement the Xyce Users Guide. It contains comprehensive, detailed information about a number of topics pertinent to the usage of Xyce. Included in this document is a netlist reference for the input-file commands and elements supported within Xyce; a command line reference, which describes the available command line arguments for Xyce; and quick-references for users of other circuit codes, such as Orcad's PSpice and Sandia's ChileSPICE.

  13. Hazard Communication Program 1.0 REFERENCE

    E-Print Network [OSTI]

    de Lijser, Peter

    Hazard Communication Program 1.0 REFERENCE California Code of Regulations, Title 8, Sections 337 the properties and potential safety and health hazards of the materials which they use or to which they are exposed. Employees who use or may be exposed to potentially hazardous substances or harmful physical

  14. Positional reference system for ultraprecision machining

    DOE Patents [OSTI]

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1980-09-12

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  15. UNIVERSITY PLANNING (SCUP) Terms of Reference

    E-Print Network [OSTI]

    Lennard, William N.

    UNIVERSITY PLANNING (SCUP) Terms of Reference: The Committee is the chief forum within Senate for critical appraisal and coordination of long-term strategic, capital and budget plans for the University planning context, it has specific responsibilities as follows: Long-Range Planning To review and recommend

  16. Campus Planning Committee Terms of Reference

    E-Print Network [OSTI]

    Victoria, University of

    1 Campus Planning Committee Terms of Reference Type: Advisory to President Charge: 1. Recognizing the academic priorities of the institution, the Committee shall advise the President on: a) the long-range plan for the physical development of the Campus; b) amendments to the approved campus plan; c) the University's proposed

  17. Fluid Neutral Momentum Transport Reference Problem

    E-Print Network [OSTI]

    Budny, Robert

    Fluid Neutral Momentum Transport Reference Problem D. P. Stotler, PPPL S. I. Krasheninnikov, UCSD 1 Summary Type of problem: kinetic or fluid neutral transport Physics or algorithm stressed: thermal force term (spatial resolution) in momentum transport equation and treatment of collisions (charge ex- change

  18. Shape Recipes: Scene Representations that Refer

    E-Print Network [OSTI]

    Freeman, William T.

    Shape Recipes: Scene Representations that Refer to the Image William T. Freeman and Antonio to estimate and store. We propose a low-dimensional rep- resentation, called a scene recipe, that relies on the image itself to de- scribe the complex scene configurations. Shape recipes are an example

  19. Office of Classroom Management A quick reference

    E-Print Network [OSTI]

    Thomas, David D.

    Office of Classroom Management A quick reference for how to navigate your classroom's technology of the camera. #12;Office of Classroom Management 1. Press any button other than the "system off" button 2. When and resources www.classroom.umn.edu Classroom Support Hotline: 612-625-1086 ·Controlsforthe

  20. Macrosegregation Macrosegregation refers to variations in composition

    E-Print Network [OSTI]

    Beckermann, Christoph

    in casting processes: (i) Flow that feeds the solidification shrinkage and the contractions of the liquidMacrosegregation Macrosegregation refers to variations in composition that occur in alloy castings variations have a detrimental impact on the subsequent processing behavior and properties of cast materials

  1. LIBRARY AND INFORMATION SERVICES DIVISION Current References

    E-Print Network [OSTI]

    . Satellne. Data. and InformationService National Oceanographic Data Center #12;· GLOBAL CLIMATE CHANGELIBRARY AND INFORMATION SERVICES DIVISION Current References (90 -1) Global Climate Change FEBRUARY of data centers on which an information system must be built. This bibliography offers a selection

  2. R Reference Manual: A gentle overview

    E-Print Network [OSTI]

    Priestley, Jennifer Lewis

    , yet similar to SAS, R is a commands-driven programming environment to execute statistical analysisR Reference Manual: A gentle overview #12;2 Developed and maintained by the Center for Statistics statistical computing packages ­ Excel, SPSS, Minitab, R and SAS. 1 Readers of this manual are assumed to have

  3. Distributed Frequency-Preserving Optimal Load Control

    E-Print Network [OSTI]

    Wierman, Adam

    Distributed Frequency-Preserving Optimal Load Control Enrique Mallada Steven H. Low California prices to incentivize the users to adapt their consumption to the true cost of generation at the time to accept more readily a stochastically fluctuating energy source, such as wind or solar generation

  4. Spring-loaded polymeric gel actuators

    DOE Patents [OSTI]

    Shahinpoor, M.

    1995-02-14

    Spring-loaded electrically controllable polymeric gel actuators are disclosed. The polymeric gels can be polyvinyl alcohol, polyacrylic acid, or polyacrylamide, and are contained in an electrolytic solvent bath such as water plus acetone. The action of the gel is mechanically biased, allowing the expansive and contractile forces to be optimized for specific applications. 5 figs.

  5. DAMAGE LOCALIZATION USING LOAD VECTORS Dionisio Bernal

    E-Print Network [OSTI]

    Bernal, Dionisio

    DAMAGE LOCALIZATION USING LOAD VECTORS Dionisio Bernal Associate Professor Department of Civil: A technique to localize damage in structures that can be treated as linear in the pre and post-damage state is presented. Central to the approach is the computation of a set of vectors, designated as Damage Locating

  6. Exploiting Emerging Data for Enhanced Load Modeling

    E-Print Network [OSTI]

    Data for Enhanced Load Modeling Final Project Report Project Team Santiago Grijalva, Project Leader information about this project, contact Santiago Grijalva Van Leer E284 Georgia Tech 777 Atlantic Dr. N.W. E Kleitsch, American Transmission Company · Naim Logic, Salt River Project · Art Mander, Tri-State G

  7. An unconventional method for load balancing

    SciTech Connect (OSTI)

    Deng, Y.; McCoy, R.A.; Marr, R.B.

    1995-12-01

    A new method of load balancing is introduced based on the idea of dynamically relocating virtual processes corresponding to computations on an abstract system with a larger number of processors. The algorithm introduced preserves the locality of nearest neighbor interactions and has been tested on simulated data and a molecular dynamics code.

  8. An unconventional method for load balancing

    SciTech Connect (OSTI)

    Deng, Y.; McCoy, R.A.; Marr, R.B.; Peierls, R.F.

    1995-08-01

    A new method of load balancing is introduced based on the idea of dynamically relocating virtual processes corresponding to computations on an abstract system with a large number of processors. The algorithm introduced preserves the locality of nearest neighbor interactions and has been tested on simulated data and a molecular dynamics code.

  9. Load Participation in Ancillary Services Workshop

    Broader source: Energy.gov [DOE]

    The Load Participation in Ancillary Services Workshop was held October 25-26, 2011, in Washington, DC. This U.S. Department of Energy workshop was attended by members of the electric power industry, researchers, and policy makers. The results of the workshop informed the Demand Response and Energy Storage Study.

  10. Valve for fuel pin loading system

    DOE Patents [OSTI]

    Christiansen, D.W.

    1984-01-01

    A cyclone valve surrounds a wall opening through which cladding is projected. An axial valve inlet surrounds the cladding. Air is drawn through the inlet by a cyclone stream within the valve. An inflatable seal is included to physically engage a fuel pin subassembly during loading of fuel pellets.

  11. 1995 Pacific Northwest Loads and Resources Study.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    1995-12-01

    The study establishes the planning basis for supplying electricity to customers. The study presents projections of regional and Federal system load and resource capabilities, and serves as a benchmark for annual BPA determinations made pursuant to the 1981 regional power sales contracts.

  12. Valve for fuel pin loading system

    DOE Patents [OSTI]

    Christiansen, David W. (Kennewick, WA)

    1985-01-01

    A cyclone valve surrounds a wall opening through which cladding is projected. An axial valve inlet surrounds the cladding. Air is drawn through the inlet by a cyclone stream within the valve. An inflatable seal is included to physically engage a fuel pin subassembly during loading of fuel pellets.

  13. Right-Sizing Laboratory Equipment Loads

    SciTech Connect (OSTI)

    Frenze, David; Greenberg, Steve; Mathew, Paul; Sartor, Dale; Starr, William

    2005-11-29

    Laboratory equipment such as autoclaves, glass washers, refrigerators, and computers account for a significant portion of the energy use in laboratories. However, because of the general lack of measured equipment load data for laboratories, designers often use estimates based on 'nameplate' rated data, or design assumptions from prior projects. Consequently, peak equipment loads are frequently overestimated. This results in oversized HVAC systems, increased initial construction costs, and increased energy use due to inefficiencies at low part-load operation. This best-practice guide first presents the problem of over-sizing in typical practice, and then describes how best-practice strategies obtain better estimates of equipment loads and right-size HVAC systems, saving initial construction costs as well as life-cycle energy costs. This guide is one in a series created by the Laboratories for the 21st Century ('Labs21') program, a joint program of the U.S. Environmental Protection Agency and U.S. Department of Energy. Geared towards architects, engineers, and facilities managers, these guides provide information about technologies and practices to use in designing, constructing, and operating safe, sustainable, high-performance laboratories.

  14. Bibliography of the Scripps Institution of Oceanography Reference Series 1994

    E-Print Network [OSTI]

    Criqui, Nan P.

    1995-01-01

    OF THE SCRIPPS INSTITUTION OF OCEANOGRAPHY REFERENCE SERIESScripps Institution of Oceanography. July 1994. 179p. 94-17Scripps Institution of Oceanography Reference Series 1994.

  15. Bibliography of the Scripps Institution of Oceanography Reference Series 1997

    E-Print Network [OSTI]

    Jennings, Paige A.

    1998-01-01

    SCRIPPS INSTITUTION OF OCEANOGRAPHY REFERENCE SERIES 97-01Scripps Institution of Oceanography Reference Series 1997.held at Scripps Institution of Oceanography 19 August 1997.

  16. Biomass Scenario Model Documentation: Data and References Lin...

    Office of Scientific and Technical Information (OSTI)

    Documentation: Data and References Lin, Y.; Newes, E.; Bush, B.; Peterson, S.; Stright, D. 09 BIOMASS FUELS BIOMASS SCENARIO MODEL; BSM; BIOMASS; BIOFUEL; MODEL; DATA; REFERENCES;...

  17. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Reference Buildings by Climate Zone and Representative City: 4B Albuquerque, New Mexico Reference Buildings by Climate Zone and Representative City: 4B Albuquerque, New...

  18. Surface Temperature Humidity Reference System Handbook - November 2005

    SciTech Connect (OSTI)

    MT Ritsche

    2005-11-30

    The Surface Temperature and Humidity Reference (SURTHREF) system is intended to provide accurate reference values of ambient temperature and relative humidity for comparison with radiosonde prelaunch values.

  19. A Method for Calculating Reference Evapotranspiration on Daily Time Scales

    E-Print Network [OSTI]

    Farmer, William

    Measures of reference evapotranspiration are essential for applications of agricultural management and water resources engineering. Using numerous esoteric variables, one can calculate daily reference evapotranspiration ...

  20. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    akfairbanksnew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 8 Fairbanks, Alaska Reference Buildings by Climate Zone...

  1. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    atxhoustonnew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 2A Houston, Texas Reference Buildings by Climate Zone...

  2. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    mdbaltimorenew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 4A Baltimore, Maryland Reference Buildings by Climate...

  3. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    agaatlantanew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 3A Atlanta, Georgia Reference Buildings by Climate Zone...

  4. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    usaflmiaminew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 1A Miami, Florida Reference Buildings by Climate Zone...

  5. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    samthelenanew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 6B Helena, Montana Reference Buildings by Climate Zone...

  6. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    acobouldernew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 5B Boulder, Colorado Reference Buildings by Climate...

  7. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    awaseattlenew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 4C Seattle, Washington Reference Buildings by Climate...

  8. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    nvlasvegasnew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 3B Las Vegas, Nevada Reference Buildings by Climate...

  9. D0 Silicon Upgrade: Upgrade Piping Loads on Cleanroom Roof

    SciTech Connect (OSTI)

    Sakla, Steve; /Fermilab

    1995-08-28

    The proposed piping layout for the DO upgrade will run along the south wall of DAB. The cryogenic service pipe runs above the upper and lower cleanroom roofs and will need to be supported by the roofs beams. Calculations were done to determine the stresses in the I-beams created by the existing and additional loads due to the upgrade. Refer to drawing no. 3823.115-ME-317283 for drawings of the piping layout. Figure 1 shows the 'plan view' portion of this drawing. The weight of the individual lines were calculated in figure 2 assuming a pipe density of O.28 lbm/in{sup 3} for stainless steel (0.12% C) and a fluid density (assuming LN2 at 1 atm) of 0.03 lbm/in{sup 3}. The weights of the corrugated steel flooring, assembly hall feed cans, support beams, and roof hatch were also included in the analysis. These loads are calculated on pgs. 5-6. A floor load of 50 lbf/ft{sup 2} was also added in order to maintain the existing floor load limit in addition to the added piping loads. Measurements of the dimensions of the I-beams determined that the nominal sizes of the beams were W8 x 21 for the lower roof and W14 x 26 for the upper roof. Pipe lengths were determined from the drawing for each of the lines on pgs. 1-2 of the calculations (refer to all piping by line numbers according to figure 2). A total weight was calculated for lines 3-9 along the south wall and lines 1-2 running along the north wall of the lower cleanroom roof. To simplify the calculations these weights were assumed to be evenly distributed on the 5 I-beam supports of the lower cleanroom roof 2.5 feet in from the south wall. The stress analysis was done using FrameMac, a 2-D finite element program for the Macintosh. Beam 3 was not included in the analysis because it is structurally equivalent to beam 1. The program outputted maximum values for shear stress, bending stress, shear force, and moments in each of the beams analyzed. These values were then compared to the allowable stresses as per the specifications and codes stated in the AISC: Manual of Steel Construction. The stresses on the roof beams needed to be determined in a number of different places. The first was in the beam itself which included the flange and web sections. The second place was at the ends of the beams where the flanges were removed to make the perpendicular connections to the other beams on the lower roof. The final point was the framed beam connection which included the bolt analysis. FrameMac calculated stresses only for the beams which included the sections where the flanges were removed to make the end connections. To analyze the connections, the allowable bending and shear stresses were solved for allowable shear and moments. This was done because FrameMac does not have the capability to analyze the dimensions for the bolts and angles used in the connections were known and the program outputted values for reaction forces and moments at the ends of the beams. Multiplying the allowable shear stress for the bolts and angle connections by their respective areas gave the allowable shear force. The allowable moment for the angle connection was calculated by multiplying the section modulus of the angle by the allowable bending stress. These allowable loads are calculated on pgs. 7-8. The allowable and maximum calculated stresses by FrameMac are summarized in a table. In conclusion, the cleanroom roofs will be able to safely support the weight of the upgrade cryogenic piping, feed cans, corrugated flooring and a 50 lbf/ft{sup 2} floor load with the addition of diagonal braces at the ends of beams 1,2,3,4, and 8. The location and size of these diagonal braces are shown in fig. 4. Also, the piping supports and feed cans will all need to be placed directly above the I-beam supports. These supports will consist of unistrut structures that will be detailed and specified separate to this analysis. The output and input data from FrameMac and the drawings used in the analysis follow the calculation pages.

  10. Smard Grid Software Applications for Distribution Network Load Forecasting Eugene A. Feinberg, Jun Fei

    E-Print Network [OSTI]

    Feinberg, Eugene A.

    of the distribution network. Keywords: load forecasting, feeder, transformer, load pocket, SmartGrid I. INTRODUCTION

  11. Better Building Alliance, Plug and Process Loads in Commercial Buildings: Capacity and Power Requirement Analysis (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2014-09-01

    This brochure addresses gaps in actionable knowledge that can help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. This brochure should be used to make these decisions so systems can operate more energy efficiently; upfront capital costs will also decrease. This information can also be used to drive changes in negotiations about PPL energy demands. It should enable brokers and tenants to agree about lower PPL capacities. Owner-occupied buildings will also benefit. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems.

  12. Ancillary-service details: regulation, load following, and generator response

    SciTech Connect (OSTI)

    Hirst, E.; Kirby, B.

    1996-09-01

    The purpose of this report is to examine empirically these intrahour and interhour load changes and the responses of a utility`s generating resources to those load changes. We analyze data, primarily from one control area, to see how it maintains ACE close to zero in an effort to meet the A1 and A2 criteria. Overall, we estimate that load following costs US electric utilities over one billion dollars a year. We first test alternative ways to identify trends over multihour periods using both regression analysis and rolling averages. Then, we consider several metrics for intrahour load following. Next we examine characteristics of load following for different time-averaging periods and compare the dynamics of loads and load following generation across these time periods. Finally, we consider the contribution of each load to the total load following requirements of the control area.

  13. Reference Design? | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onRAPID/Geothermal/Exploration/Colorado <RAPID/Geothermal/WaterEnergyRedfield CampusReedsville,Reference Design? Home

  14. 1996 Pacific Northwest Loads and Resources Study.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    1996-12-01

    The Pacific Northwest Loads and Resources Study (White Book) is published annually by BPA and establishes the planning basis for supplying electricity to customers. It serves a dual purpose. First, the White Book presents projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. Second, the White Book serves as a benchmark for annual BPA determinations made pursuant to the 1981 regional power sales contracts. Specifically, BPA uses the information in the White Book for determining the notice required when customers request to increase or decrease the amount of power purchased from BPA. Aside from these purposes, the White Book is used for input to BPA`s resource planning process. The White Book compiles information obtained from several formalized resource planning reports and data submittals, including those from the Northwest Power Planning Council (Council) and the Pacific Northwest Utilities Conference Committee (PNUCC). 11 figs., 12 tabs.

  15. A Novel Approach to Determining Motor Load 

    E-Print Network [OSTI]

    Brown, M.

    1992-01-01

    TO DETERMINING MOTOR LOAD by Michael Brown Georgia Tech Research Institute Atlanta, Georgia ABSTRACf Properly sized electric motors are essential if industrial plant efficiency is to be optimized and energy costs minimized. Because of the difficully..., oversizing is usually unwarranted and ultimately leads to ineffi-eiency and energy waste. This paper ex.amines methods to determine underloaded motor operdtion and presents an evaluation of the savings afforded by properly sizing of motors. MOTOR...

  16. Advanced Reactors Transition Program Resource Loaded Schedule

    SciTech Connect (OSTI)

    GANTT, D.A.

    2000-01-12

    The Advanced Reactors Transition (ART) Resource Loaded Schedule (RLS) provides a cost and schedule baseline for managing the project elements within the ART Program. The Fast Flux Test Facility (FETF) activities are delineated through the end of FY 2000, assuming continued standby. The Nuclear Energy (NE) Legacies and Plutonium Recycle Test Reactor (PRTR) activities are delineated through the end of the deactivation process. This revision reflects the 19 Oct 1999 baseline.

  17. Electricity pricing for conservation and load shifting

    SciTech Connect (OSTI)

    Orans, Ren; Woo, C.K.; Horii, Brian; Chait, Michele; DeBenedictis, Andrew

    2010-04-15

    The electricity industry is facing the challenge of increasing costs of reliably meeting demand growth and fully complying with legislative renewable portfolio standards and greenhouse gas reduction targets. However, an electric utility's existing tariffs often don't have rates that increase with consumption volume or vary by time of use, thus not fully exploiting the potential benefits from customer conservation and load shifting. (author)

  18. Metal loading and reactivity of Zeolite Y 

    E-Print Network [OSTI]

    Sa?enz, Marc Gerard

    1988-01-01

    V) are transi- tion metal oxides or sulfides on an alumina support. These catalysts were not specifically developed for hydrodenitrogenaiion but were adopted from hydrocracking or hydrodesul- furization (HDS) processes. HDN is more difficult than HDS; thus... No. ;&778365, "Hydrocracking and Hydrodenitrogenation of Shale Oil" (7). The patent disclosed a class of catalysi. s based on large pore zeolites loaded v;ith transition metals. The zeolite based catalysts were preferred over the traditional alumina...

  19. Loading Relativistic Maxwell Distributions in Particle Simulations

    E-Print Network [OSTI]

    Zenitani, Seiji

    2015-01-01

    Numerical algorithms to load relativistic Maxwell distributions in particle-in-cell (PIC) and Monte-Carlo simulations are presented. For stationary relativistic Maxwellian, the inverse transform method and the Sobol algorithm are reviewed. To boost particles to obtain relativistic shifted-Maxwellian, two rejection methods are proposed in a physically transparent manner. Their acceptance efficiencies are ${\\approx}50\\%$ for generic cases and $100\\%$ for symmetric distributions. They can be combined with arbitrary base algorithms.

  20. Batch load anaerobic digestion of dairy manure 

    E-Print Network [OSTI]

    Egg, Richard P

    1979-01-01

    and medium size dairy operations unless the pro- cess can be made more efficient or some other economic benefit can be derived from the manure. A recent study indicated that a batch load process might be more efficient in waste stabilization and biogas... rate of biogas production was 0. 69 liters biogas/liter digester/ day. This volumetric biogas production increased with increasing influent total solids concentration. Influent concentration had little effect on other biogas production parameters...

  1. Effects of toughness anisotropy and combined tension, torsion, and bending loads on fracture behavior of ferritic nuclear pipe

    SciTech Connect (OSTI)

    Mohan, R.; Marshall, C.; Ghadiali, N.; Wilkowski, G. [Battelle, Columbus, OH (United States)

    1997-04-01

    This paper summarizes work on angled through-wall-crack initiation and combined loading effects on ferritic nuclear pipe performed as part of the Nuclear Regulatory Commission`s research program entitled {open_quotes}Short Cracks In Piping an Piping Welds{close_quotes}. The reader is referred to Reference 1 for details of the experiments and analyses conducted as part of this program. The major impetus for this work stemmed from the observation that initially circumferentially oriented cracks in carbon steel pipes exhibited a high tendency to grow at a different angle when the cracked pipes were subjected to bending or bending plus pressure loads. This failure mode was little understood, and the effect of angled crack grown from an initially circumferential crack raised questions about how cracks in a piping system subjected to combined loading with torsional stresses would behave. There were three major efforts undertaken in this study. The first involved a literature review to assess the causes of toughness anisotropy in ferritic pipes and to develop strength and toughness data as a function of angle from the circumferential plane. The second effort was an attempt to develop a screening criterion based on toughness anisotropy and to compare this screening criterion with experimental pipe fracture data. The third and more significant effort involved finite element analyses to examine why cracks grow at an angle and what is the effect of combined loads with torsional stresses on a circumferentially cracked pipe. These three efforts are summarized.

  2. Transmission Reliability "Load as a Resource" Peer Review Materials...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    "Load as a Resource" Peer Review Materials Now Available Transmission Reliability "Load as a Resource" Peer Review Materials Now Available September 25, 2014 - 11:43am Addthis OE's...

  3. Assessing and Reducing Miscellaneous Electric Loads (MELs) in Lodging

    SciTech Connect (OSTI)

    Rauch, Emily M.

    2011-09-01

    Miscellaneous electric loads (MELs) are the loads outside of a building's core functions of heating, ventilating, air conditioning, lighting, and water heating. This report reviews methods to reduce MELs in lodging.

  4. Electrical Energy Conservation and Load Management - An Industrial User's Viewpoint 

    E-Print Network [OSTI]

    Jackson, C. E.

    1984-01-01

    load management has been implemented already. Additional load management is possible; however, optimizing it will require close industry and electric utility company cooperation to develop new incentives and rate structures to make it economically...

  5. Load Management and Houston Lighting and Power Co. 

    E-Print Network [OSTI]

    Drawe, R. G.; Ramsay, I. M.

    1984-01-01

    Defining Load Management as influencing of customer loads in order to shift the time use of electric power and energy, encompasses a broad spectrum of activities at Houston Lighting & Power Company. This paper describes those activities by directing...

  6. Calculation of Extreme Wave Loads on Coastal Highway Bridges 

    E-Print Network [OSTI]

    Meng, Bo

    2010-01-14

    Coastal bridges are exposed to severe wave, current and wind forces during a hurricane. Most coastal bridges are not designed to resist wave loads in such extreme situations, and there are no existing analytical methods to calculate wave loads...

  7. Crack coalescence in rock-like material under cycling loading

    E-Print Network [OSTI]

    Ko, Tae Young, 1973-

    2005-01-01

    A total of 170 tests (68 tests for monotonic loading, 102 tests for cyclic loading) have been performed to investigate crack initiation, propagation and coalescence. The specimens have two pre-existing flaws which are ...

  8. SLUDGE TREATMENT PROJECT COST COMPARISON BETWEEN HYDRAULIC LOADING AND SMALL CANISTER LOADING CONCEPTS

    SciTech Connect (OSTI)

    GEUTHER J; CONRAD EA; RHOADARMER D

    2009-08-24

    The Sludge Treatment Project (STP) is considering two different concepts for the retrieval, loading, transport and interim storage of the K Basin sludge. The two design concepts under consideration are: (1) Hydraulic Loading Concept - In the hydraulic loading concept, the sludge is retrieved from the Engineered Containers directly into the Sludge Transport and Storage Container (STSC) while located in the STS cask in the modified KW Basin Annex. The sludge is loaded via a series of transfer, settle, decant, and filtration return steps until the STSC sludge transportation limits are met. The STSC is then transported to T Plant and placed in storage arrays in the T Plant canyon cells for interim storage. (2) Small Canister Concept - In the small canister concept, the sludge is transferred from the Engineered Containers (ECs) into a settling vessel. After settling and decanting, the sludge is loaded underwater into small canisters. The small canisters are then transferred to the existing Fuel Transport System (FTS) where they are loaded underwater into the FTS Shielded Transfer Cask (STC). The STC is raised from the basin and placed into the Cask Transfer Overpack (CTO), loaded onto the trailer in the KW Basin Annex for transport to T Plant. At T Plant, the CTO is removed from the transport trailer and placed on the canyon deck. The CTO and STC are opened and the small canisters are removed using the canyon crane and placed into an STSC. The STSC is closed, and placed in storage arrays in the T Plant canyon cells for interim storage. The purpose of the cost estimate is to provide a comparison of the two concepts described.

  9. Strain rate and inertial effects on impact loaded single-edge notch bend specimens

    SciTech Connect (OSTI)

    Vargas, P.M.; Dodds, R.H. Jr.

    1995-12-31

    Many problems in fracture mechanics of ductile metals involve surface breaking defects located in structures subjected to impact or blast. When the severity of impact loads is sufficient to produce large inelastic deformations, the assessment of crack-tip conditions must include the effects of plasticity, strain rate and inertia. This work examines the interaction of impact loading, inelastic material deformation and rate sensitivity with the goal of improving the interpretation of ductile fracture toughness values measured under dynamic loading. The authors focus on shallow and deeply notched bend test specimens, SE(B)s, employed routinely to measure the static fracture toughness of a material. A thorough understanding of the test specimen`s dynamic behavior is a prerequisite to the application of measured fracture properties in structural applications. Three-dimensional, nonlinear dynamic analyses are performed for SE(B) fracture specimens subjected to impact loading. Loading rates obtained in conventional drop tower tests are applied in the analyses. An explicit time integration procedure coupled with an efficient (one-point) element integration scheme is employed to compute the dynamic response of the specimen. Strain-rate sensitivity is introduced via a new, efficient implementation of the Bodner-Partom viscoplastic constitutive model. Material properties for A533B steel are used in the analyses. Static analyses of the SE(B) specimens provide baseline responses for assessment of inertial effects. Similarly, dynamic analyses using a strain-rate insensitive material provide reference responses for the assessment of strain rate effects. Strains at key locations on the specimens and the support reactions are extracted from the analyses to assess the accuracy of static formulas commonly used to estimate applied J values. Inertial effects on the applied J are quantified by examining the acceleration component of J evaluated through a domain integral procedure.

  10. I. Introduction Equivalent loading of induction machines are

    E-Print Network [OSTI]

    Szabados, Barna

    phase synchronous machine. If the synchronous machine had a rotor with two windings with a spacial phaseI. Introduction Equivalent loading of induction machines are used to test machines for temperature loading tests, lead to the conclusion that synthetic loading is a viable simple test for large machines

  11. Extreme Loads for an Offshore Wind Turbine using Statistical

    E-Print Network [OSTI]

    Manuel, Lance

    Extreme Loads for an Offshore Wind Turbine using Statistical Extrapolation from Limited Field Data,itiscommontoeithercarry out extensive simulation studies or undertake a field measurement campaign. At the Blyth offshore wind here is to estimate extreme loads for an offshore wind turbine for which the environmental and load

  12. AIAA980057 RELATING TURBULENCE TO WIND TURBINE BLADE LOADS

    E-Print Network [OSTI]

    Sweetman, Bert

    AIAA­98­0057 RELATING TURBULENCE TO WIND TURBINE BLADE LOADS: PARAMETRIC STUDY WITH MULTIPLE that is most useful in estimating fatigue loads on wind turbine blades. The histograms of rainflow counted for flapwise loads on three horizontal axis wind tur­ bines(HAWTs). In the case of two of these turbines

  13. Design Loads for Wind Turbines using the Environmental Contour Method

    E-Print Network [OSTI]

    Manuel, Lance

    Design Loads for Wind Turbines using the Environmental Contour Method Korn Saranyasoontorn, TX 78712 When interest is in establishing ultimate design loads for wind turbines such that a service). The parametric conditional load distri- butions require extensive turbine response simulations over the entire

  14. High-Resolution Residential Feeder Load Characterization and Variability Modelling

    E-Print Network [OSTI]

    data. Ideally the method should be validated or updated with 1- second load data from the region-15-minute variability estimates for modeling dynamic load profiles. An autoregressive, AR(1) functionHigh-Resolution Residential Feeder Load Characterization and Variability Modelling Andrew Pohl, Jay

  15. Lifetime Benefits through Load Balancing in Homogeneous Sensor Networks

    E-Print Network [OSTI]

    Haenggi, Martin

    , battery depletion is emulated so that it becomes possible to actually measure the load balancingLifetime Benefits through Load Balancing in Homogeneous Sensor Networks Daniele Puccinelli network. The use of load balancing schemes can be expected to provide significant lifetime benefits

  16. Stress and Cognitive Load in Multimodal Conversational Interactions

    E-Print Network [OSTI]

    Nijholt, Anton

    Stress and Cognitive Load in Multimodal Conversational Interactions Andreea Niculescu, Yujia Cao conversational interactions is determined by many influence parameters. Stress and cognitive load are two of them. In order to assess the impact of stress and cognitive load on the perceived conversational quality

  17. Automatic Intra-Application Load Balancing for Heterogeneous Systems

    E-Print Network [OSTI]

    Huang, Wei

    Automatic Intra-Application Load Balancing for Heterogeneous Systems Michael Boyer, Shuai Che AMD #12;2 | Automatic Intra-Application Load Balancing | June 14, 2011 Motivation Many applications;3 | Automatic Intra-Application Load Balancing | June 14, 2011 Leveraging Multiple Devices Writing correct

  18. Forecasting Hourly Electricity Load Profile Using Neural Networks

    E-Print Network [OSTI]

    Koprinska, Irena

    Forecasting Hourly Electricity Load Profile Using Neural Networks Mashud Rana and Irena Koprinska--We present INN, a new approach for predicting the hourly electricity load profile for the next day from a time series of previous electricity loads. It uses an iterative methodology to make the predictions

  19. Department of Energy Construction Safety Reference Guide

    SciTech Connect (OSTI)

    Not Available

    1993-09-01

    DOE has adopted the Occupational Safety and Health Administration (OSHA) regulations Title 29 Code of Federal Regulations (CFR) 1926 ``Safety and Health Regulations for Construction,`` and related parts of 29 CFR 1910, ``Occupational Safety and Health Standards.`` This nonmandatory reference guide is based on these OSHA regulations and, where appropriate, incorporates additional standards, codes, directives, and work practices that are recognized and accepted by DOE and the construction industry. It covers excavation, scaffolding, electricity, fire, signs/barricades, cranes/hoists/conveyors, hand and power tools, concrete/masonry, stairways/ladders, welding/cutting, motor vehicles/mechanical equipment, demolition, materials, blasting, steel erection, etc.

  20. 1993 Solid Waste Reference Forecast Summary

    SciTech Connect (OSTI)

    Valero, O.J.; Blackburn, C.L. [Westinghouse Hanford Co., Richland, WA (United States); Kaae, P.S.; Armacost, L.L.; Garrett, S.M.K. [Pacific Northwest Lab., Richland, WA (United States)

    1993-08-01

    This report, which updates WHC-EP-0567, 1992 Solid Waste Reference Forecast Summary, (WHC 1992) forecasts the volumes of solid wastes to be generated or received at the US Department of Energy Hanford Site during the 30-year period from FY 1993 through FY 2022. The data used in this document were collected from Westinghouse Hanford Company forecasts as well as from surveys of waste generators at other US Department of Energy sites who are now shipping or plan to ship solid wastes to the Hanford Site for disposal. These wastes include low-level and low-level mixed waste, transuranic and transuranic mixed waste, and nonradioactive hazardous waste.

  1. A New Solar Irradiance Reference Spectrum

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach HomeA Better Anode Design to Improve Lithium-Ion Batteries PrintA New Solar Irradiance Reference Spectrum

  2. Technical Reference for Hydrogen Compatibility of Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired Solar Fuel ProductionRecoverable15/2008 Technical Reference on

  3. Technical Reference on Hydrogen Compatibility of Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired Solar Fuel ProductionRecoverable15/2008 Technical Reference onType

  4. Technical Reference on Hydrogen Compatibility of Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired Solar Fuel ProductionRecoverable15/2008 Technical Reference onType1

  5. Administrator References and Logins | Advanced Photon Source

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room News Publications Traditional Knowledge KiosksAboutHelp & Reference Users Home Contacts

  6. Property:Reference material | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to:EA EIS Report Url Jump to:Programmable WavemakingPurchasersReference

  7. Commercial Reference Buildings | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTIONRobertsdale, Alabama (Utility Company)| Open EnergyColoradoBiomass EnergyCity,Commercial Reference

  8. Reference worldwide model for antineutrinos from reactors

    E-Print Network [OSTI]

    Marica Baldoncini; Ivan Callegari; Giovanni Fiorentini; Fabio Mantovani; Barbara Ricci; Virginia Strati; Gerti Xhixha

    2015-02-16

    Antineutrinos produced at nuclear reactors constitute a severe source of background for the detection of geoneutrinos, which bring to the Earth's surface information about natural radioactivity in the whole planet. In this framework we provide a reference worldwide model for antineutrinos from reactors, in view of reactors operational records yearly published by the International Atomic Energy Agency (IAEA). We evaluate the expected signal from commercial reactors for ongoing (KamLAND and Borexino), planned (SNO+) and proposed (Juno, RENO-50, LENA and Hanohano) experimental sites. Uncertainties related to reactor antineutrino production, propagation and detection processes are estimated using a Monte Carlo based approach, which provides an overall site dependent uncertainty on the signal in the geoneutrino energy window on the order of 3%. We also implement the off-equilibrium correction to the reference reactor spectra associated with the long-lived isotopes and we estimate a 2.4% increase of the unoscillated event rate in the geoneutrino energy window due to the storage of spent nuclear fuels in the cooling pools. We predict that the research reactors contribute to less than 0.2% to the commercial reactor signal in the investigated 14 sites. We perform a multitemporal analysis of the expected reactor signal over a time lapse of 10 years using reactor operational records collected in a comprehensive database published at www.fe.infn.it/antineutrino.

  9. Generic Argillite/Shale Disposal Reference Case

    SciTech Connect (OSTI)

    Zheng, Liange; Colon, Carlos Jové; Bianchi, Marco; Birkholzer, Jens

    2014-08-08

    Radioactive waste disposal in a deep subsurface repository hosted in clay/shale/argillite is a subject of widespread interest given the desirable isolation properties, geochemically reduced conditions, and widespread geologic occurrence of this rock type (Hansen 2010; Bianchi et al. 2013). Bianchi et al. (2013) provides a description of diffusion in a clay-hosted repository based on single-phase flow and full saturation using parametric data from documented studies in Europe (e.g., ANDRA 2005). The predominance of diffusive transport and sorption phenomena in this clay media are key attributes to impede radionuclide mobility making clay rock formations target sites for disposal of high-level radioactive waste. The reports by Hansen et al. (2010) and those from numerous studies in clay-hosted underground research laboratories (URLs) in Belgium, France and Switzerland outline the extensive scientific knowledge obtained to assess long-term clay/shale/argillite repository isolation performance of nuclear waste. In the past several years under the UFDC, various kinds of models have been developed for argillite repository to demonstrate the model capability, understand the spatial and temporal alteration of the repository, and evaluate different scenarios. These models include the coupled Thermal-Hydrological-Mechanical (THM) and Thermal-Hydrological-Mechanical-Chemical (THMC) models (e.g. Liu et al. 2013; Rutqvist et al. 2014a, Zheng et al. 2014a) that focus on THMC processes in the Engineered Barrier System (EBS) bentonite and argillite host hock, the large scale hydrogeologic model (Bianchi et al. 2014) that investigates the hydraulic connection between an emplacement drift and surrounding hydrogeological units, and Disposal Systems Evaluation Framework (DSEF) models (Greenberg et al. 2013) that evaluate thermal evolution in the host rock approximated as a thermal conduction process to facilitate the analysis of design options. However, the assumptions and the properties (parameters) used in these models are different, which not only make inter-model comparisons difficult, but also compromise the applicability of the lessons learned from one model to another model. The establishment of a reference case would therefore be helpful to set up a baseline for model development. A generic salt repository reference case was developed in Freeze et al. (2013) and the generic argillite repository reference case is presented in this report. The definition of a reference case requires the characterization of the waste inventory, waste form, waste package, repository layout, EBS backfill, host rock, and biosphere. This report mainly documents the processes in EBS bentonite and host rock that are potentially important for performance assessment and properties that are needed to describe these processes, with brief description other components such as waste inventory, waste form, waste package, repository layout, aquifer, and biosphere. A thorough description of the generic argillite repository reference case will be given in Jové Colon et al. (2014).

  10. Rotordynamic coefficients for a load-between-pad, flexible-pivot tilting pad bearing at high loads 

    E-Print Network [OSTI]

    Hensley, John Eric

    2006-10-30

    The dynamic and static performance of a flexure-pivot tilting pad bearing is presented at a load between pad configuration for various load and speed combinations. A similar work performed on the same bearing at lower loads ranging from 0-1 MPa (0...

  11. Investigation of sands subjected to dynamic loading 

    E-Print Network [OSTI]

    Reeves, Gary Neil

    1967-01-01

    Subject: Civil EnEineering LABORATORY INVESTIGATION OF SANDS SUBJECTED TO DYNAMIC LOADING A Thesis by Gary N. Reeves Approved as to style and content by: Chairman of Committee Head of Department Membe Me er August 1967 ACIINOWLEDGR&J. 'NTS I... am indebted to Dz. II. M. Coylc ior his advice and guidan& e while serving as chairman of my Graduate Advisory Cormaii tcc. Grati- tude is also expressed to Dr. T. J. I:irsch for his suggestions and assistance, and to Dr. J. R. Runkles, both...

  12. Customer Load Eligibility Guidelines (CLEG), April 2015

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would like submit theCovalent Bonding inCustomer-Comments Sign In About | CUSTOMER LOAD

  13. electric load data | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop IncIowa (UtilityMichigan)data book Home Graham7781's picturedownloadelectric load

  14. Tackling Optimization Challenges in Industrial Load Control and Full-Duplex Radios

    E-Print Network [OSTI]

    Gholian, Armen

    2015-01-01

    xii List of Tables Industrial vs. residential loadII Optimal Industrial Load Control in Smart Grid 3and Related Work 4 Basic Industrial Load Control: A Case

  15. Experimental comparison of zone cooling load between radiant and air systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Bauman, Fred; Schiavon, Stefano

    2014-01-01

    be used for radiant system cooling load, which should beKeyword Radiant Cooling System, Cooling load, Air system,guidance on radiant system cooling load prediction and

  16. Estimation of structural reliability under combined loads. [PWR; BWR

    SciTech Connect (OSTI)

    Shinozuka, M.; Kako, T.; Hwang, H.; Brown, P.; Reich, M.

    1983-01-01

    For the overall safety evaluation of seismic category I structures subjected to various load combinations, a quantitative measure of the structural reliability in terms of a limit state probability can be conveniently used. For this purpose, the reliability analysis method for dynamic loads, which has recently been developed by the authors, was combined with the existing standard reliability analysis procedure for static and quasi-static loads. The significant parameters that enter into the analysis are: the rate at which each load (dead load, accidental internal pressure, earthquake, etc.) will occur, its duration and intensity. All these parameters are basically random variables for most of the loads to be considered. For dynamic loads, the overall intensity is usually characterized not only by their dynamic components but also by their static components. The structure considered in the present paper is a reinforced concrete containment structure subjected to various static and dynamic loads such as dead loads, accidental pressure, earthquake acceleration, etc. Computations are performed to evaluate the limit state probabilities under each load combination separately and also under all possible combinations of such loads.

  17. DC switching regulated power supply for driving an inductive load

    DOE Patents [OSTI]

    Dyer, George R. (Norris, TN)

    1986-01-01

    A power supply for driving an inductive load current from a dc power supply hrough a regulator circuit including a bridge arrangement of diodes and switching transistors controlled by a servo controller which regulates switching in response to the load current to maintain a selected load current. First and second opposite legs of the bridge are formed by first and second parallel-connected transistor arrays, respectively, while the third and fourth legs of the bridge are formed by appropriately connected first and second parallel connected diode arrays, respectively. The regulator may be operated in three "stages" or modes: (1) For current runup in the load, both first and second transistor switch arrays are turned "on" and current is supplied to the load through both transistor arrays. (2) When load current reaches the desired level, the first switch is turned "off", and load current "flywheels" through the second switch array and the fourth leg diode array connecting the second switch array in series with the load. Current is maintained by alternating between modes 1 and 2 at a suitable duty cycle and switching rate set by the controller. (3) Rapid current rundown is accomplished by turning both switch arrays "off", allowing load current to be dumped back into the source through the third and fourth diode arrays connecting the source in series opposition with the load to recover energy from the inductive load. The three operating states are controlled automatically by the controller.

  18. DC switching regulated power supply for driving an inductive load

    DOE Patents [OSTI]

    Dyer, G.R.

    1983-11-29

    A dc switching regulated power supply for driving an inductive load is provided. The regulator basic circuit is a bridge arrangement of diodes and transistors. First and second opposite legs of the bridge are formed by first and second parallel-connected transistor arrays, respectively, while the third and fourth legs of the bridge are formed by appropriately connected first and second parallel connected diode arrays, respectively. A dc power supply is connected to the input of the bridge and the output is connected to the load. A servo controller is provided to control the switching rate of the transistors to maintain a desired current to the load. The regulator may be operated in three stages or modes: (1) for current runup in the load, both first and second transistor switch arrays are turned on and current is supplied to the load through both transistor arrays. (2) When load current reaches the desired level, the first switch is turned off, and load current flywheels through the second switch array and the fourth leg diode array connecting the second switch array in series with the load. Current is maintained by alternating between modes 1 and 2 at a suitable duty cycle and switching rate set by the controller. (3) Rapid current rundown is accomplished by turning both switch arrays off, allowing load current to be dumped back into the source through the third and fourth diode arrays connecting the source in series opposition with the load to recover energy from the inductive load.

  19. SAPHIRE 8 Volume 7 - Data Loading

    SciTech Connect (OSTI)

    K. J. Kvarfordt; S. T. Wood; C. L. Smith; S. R. Prescott

    2011-03-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE Version 8 is funded by the U.S. Nuclear Regulatory Commission and developed by the Idaho National Laboratory. This report is intended to assist the user to enter PRA data into the SAPHIRE program using the built-in MAR-D ASCII-text file data transfer process. Towards this end, a small sample database is constructed and utilized for demonstration. Where applicable, the discussion includes how the data processes for loading the sample database relate to the actual processes used to load a larger PRA models. The procedures described herein were developed for use with SAPHIRE Version 8. The guidance specified in this document will allow a user to have sufficient knowledge to both understand the data format used by SAPHIRE and to carry out the transfer of data between different PRA projects.

  20. Analyzing Design Heating Loads in Superinsulated Buildings

    SciTech Connect (OSTI)

    Arena, Lois

    2015-06-16

    The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) worked with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This communityscale project consists of 40 housing units—15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. For the research component of this project, CARB analyzed current heating system sizing methods for superinsulated homes in cold climates to determine if changes in building load calculation methodology should be recommended. Actual heating energy use was monitored and compared to results from the Air Conditioning Contractors of America’s Manual J8 (MJ8) and the Passive House Planning Package software. Results from that research indicate that MJ8 significantly oversizes heating systems for superinsulated homes and that thermal inertia and internal gains should be considered for more accurate load calculations.

  1. WECC Variable Generation Planning Reference Book

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Du, Pengwei; Etingov, Pavel V.; Ma, Jian; Vyakaranam, Bharat

    2013-05-14

    This planning reference book is a document reflecting a Western Electricity Coordination Council (WECC) effort to put together multiple sources of information and provide a clear, systemic, comprehensive outline of the problems, both existing and anticipated; their impacts on the system; currently used and proposed solutions by the industry and research community; planning practices; new technologies, equipment, and standards; and expected future trends. This living (periodically updated) document could help WECC and other practicing engineers, especially the younger generation of engineers joining the workforce, to get familiar with a large variety of information related to the integration of variable resources into the WECC system, bypassing in part the need for time-consuming information gathering and learning processes from more experienced engineers or from the literature.

  2. ACAA fly ash basics: quick reference card

    SciTech Connect (OSTI)

    2006-07-01

    Fly ash is a fine powdery material created when coal is burned to generate electricity. Before escaping into the environment via the utility stacks, the ash is collected and may be stored for beneficial uses or disposed of, if necessary. The use of fly ash provides environmental benefits, such as the conservation of natural resources, the reduction of greenhouse gas emissions and eliminating the needed for ash disposal in landfills. It is also a valuable mineral resource that is used in construction and manufacturing. Fly ash is used in the production of Portland cement, concrete, mortars and stuccos, manufactured aggregates along with various agricultural applications. As mineral filler, fly ash can be used for paints, shingles, carpet backing, plastics, metal castings and other purposes. This quick reference card is intended to provide the reader basic source, identification and composition, information specifically related to fly ash.

  3. Semantic Features for Classifying Referring Search Terms

    SciTech Connect (OSTI)

    May, Chandler J.; Henry, Michael J.; McGrath, Liam R.; Bell, Eric B.; Marshall, Eric J.; Gregory, Michelle L.

    2012-05-11

    When an internet user clicks on a result in a search engine, a request is submitted to the destination web server that includes a referrer field containing the search terms given by the user. Using this information, website owners can analyze the search terms leading to their websites to better understand their visitors needs. This work explores some of the features that can be used for classification-based analysis of such referring search terms. We present initial results for the example task of classifying HTTP requests countries of origin. A system that can accurately predict the country of origin from query text may be a valuable complement to IP lookup methods which are susceptible to the obfuscation of dereferrers or proxies. We suggest that the addition of semantic features improves classifier performance in this example application. We begin by looking at related work and presenting our approach. After describing initial experiments and results, we discuss paths forward for this work.

  4. Webinar October 13: Reference Designs for Hydrogen Fueling Stations...

    Broader source: Energy.gov (indexed) [DOE]

    titled "Reference Designs for Hydrogen Fueling Stations" on Tuesday, October 13, from 12 to 1 p.m. Eastern Daylight Time (EDT). The goal of the H2FIRST Reference Station Design...

  5. United States Department of the Interior - RM-53 - Reference...

    Open Energy Info (EERE)

    search OpenEI Reference LibraryAdd to library PermittingRegulatory Guidance - GuideHandbook: United States Department of the Interior - RM-53 - Reference Manual - Special Park...

  6. ORNL/TM-2012/501 Small Hydropower Cost Reference

    E-Print Network [OSTI]

    Post, Wilfred M.

    ORNL/TM-2012/501 Small Hydropower Cost Reference Model October 2012 Prepared by Qin Fen (Katherine Government or any agency thereof. #12;ORNL/TM-2012/501 Small Hydropower Cost Reference Model Final Project

  7. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    hicago-oharenew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 5A Chicago, Illinois Reference Buildings by Climate...

  8. H2FIRST Reference Station Design Task: Project Deliverable 2...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Reference Station Design Task: Project Deliverable 2-2 H2FIRST Reference Station Design Task: Project Deliverable 2-2 This H2FIRST project report, published in April 2015, presents...

  9. Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference

    E-Print Network [OSTI]

    Wechsler, Risa H.

    Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference Department: Chemical permit regulations are designed to track, record, and control air pollutants belonging to several on chemical classifications. This reference outlines major categories of air pollutants found at SLAC

  10. Lighten Your Load...productwatch Using Geofoams to Reduce Structural Design Loads from the Ground

    E-Print Network [OSTI]

    Horvath, John S.

    - and roof- 8 insulation material. You can now add to these myriad consumer and structural uses the fact gravity and seismic loads. Perhaps most importantly, EPS geofoam has proven to be cost effective for both thermal insulation plus one or more others) can be obtained from one geofoam product which enhances

  11. RECENT REFERENCES: JULY 1, 2006 TO SEPTEMBER 30, 2006

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2006-09-30

    This document lists experimental references added to Nuclear Science References (NSR) during the period July 1, 2006 to September 30, 2006. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  12. RECENT REFERENCES: JANUARY 1, 2005 TO DECEMBER 31, 2005

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2005-12-31

    This document lists experimental references added to Nuclear Science References (NSR) during the period January 1, 2005 to December 31, 2005. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  13. RECENT REFERENCES: APRIL 1, 2006 TO JUNE 30, 2006

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2006-06-30

    This document lists experimental references added to Nuclear Science References (NSR) during the period April 1, 2006 to June 30, 2006. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  14. RECENT REFERENCES: OCTOBER 1, 2005 TO DECEMBER 31, 2005

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2005-12-31

    This document lists experimental references added to Nuclear Science References (NSR) during the period October 1, 2005 to December 31, 2005. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  15. On the Intrinsic Locality Properties of Web Reference Streams

    E-Print Network [OSTI]

    Keinan, Alon

    On the Intrinsic Locality Properties of Web Reference Streams Rodrigo Fonseca Virg´ilio Almeida in the study of Web reference streams: sequences of requests for Web objects. In particular, many studies have into the nature of reference stream transformations in the Web. I. INTRODUCTION Considerable effort has gone

  16. Auxiliary Cooling Loads in Passively Cooled Buildings: An Experimental Research Study 

    E-Print Network [OSTI]

    Fairey, P.; Vieira, R.; Chandra, S.; Kerestecioglu, A.; Kalaghchy, S.

    1984-01-01

    Currently accepted methods of passive cooling offset only sensible building loads. In the warm, humid southeastern gulf coast climates the latent building load can comprise 35% of the building load in the typical residence. As the sensible load...

  17. Comparison of Second-Order Loads on a Semisubmersible Floating Wind Turbine: Preprint

    SciTech Connect (OSTI)

    Gueydon, S.; Duarte, T.; Jonkman, J.; Bayati, I.; Sarmento, A.

    2014-03-01

    As offshore wind projects move to deeper waters, floating platforms become the most feasible solution for supporting the turbines. The oil and gas industry has gained experience with floating platforms that can be applied to offshore wind projects. This paper focuses on the analysis of second-order wave loading on semisubmersible platforms. Semisubmersibles, which are being chosen for different floating offshore wind concepts, are particularly prone to slow-drift motions. The slack catenary moorings usually result in large natural periods for surge and sway motions (more than 100 s), which are in the range of the second-order difference-frequency excitation force. Modeling these complex structures requires coupled design codes. Codes have been developed that include turbine aerodynamics, hydrodynamic forces on the platform, restoring forces from the mooring lines, flexibility of the turbine, and the influence of the turbine control system. In this paper two different codes are employed: FAST, which was developed by the National Renewable Energy Laboratory, and aNySIM, which was developed by the Maritime Research Institute Netherlands. The hydrodynamic loads are based on potential-flow theory, up to the second order. Hydrodynamic coefficients for wave excitation, radiation, and hydrostatic forces are obtained with two different panel codes, WAMIT (developed by the Massachusetts Institute of Technology) and DIFFRAC (developed by MARIN). The semisubmersible platform, developed for the International Energy Agency Wind Task 30 Offshore Code Comparison Collaboration Continuation project is used as a reference platform. Irregular waves are used to compare the behavior of this platform under slow-drift excitation loads. The results from this paper highlight the effects of these loads on semisubmersible-type platforms, which represent a promising solution for the commercial development of the offshore deepwater wind resource.

  18. Active load control techniques for wind turbines.

    SciTech Connect (OSTI)

    van Dam, C.P.; Berg, Dale E.; Johnson, Scott J.

    2008-07-01

    This report provides an overview on the current state of wind turbine control and introduces a number of active techniques that could be potentially used for control of wind turbine blades. The focus is on research regarding active flow control (AFC) as it applies to wind turbine performance and loads. The techniques and concepts described here are often described as 'smart structures' or 'smart rotor control'. This field is rapidly growing and there are numerous concepts currently being investigated around the world; some concepts already are focused on the wind energy industry and others are intended for use in other fields, but have the potential for wind turbine control. An AFC system can be broken into three categories: controls and sensors, actuators and devices, and the flow phenomena. This report focuses on the research involved with the actuators and devices and the generated flow phenomena caused by each device.

  19. Optically Loaded Semiconductor Quantum Memory Register

    E-Print Network [OSTI]

    Danny Kim; Andrey A. Kiselev; Richard S. Ross; Matthew T. Rakher; Cody Jones; Thaddeus D. Ladd

    2015-07-30

    We propose and analyze an optically loaded quantum memory exploiting capacitive coupling between self-assembled quantum dot molecules and electrically gated quantum dot molecules. The self-assembled dots are used for spin-photon entanglement, which is transferred to the gated dots for long-term storage or processing via a teleportation process heralded by single-photon detection. We illustrate a device architecture enabling this interaction and we outline its operation and fabrication. We provide self-consistent Poisson-Schroedinger simulations to establish the design viability and refine the design, and to estimate the physical coupling parameters and their sensitivities to dot placement. The device we propose generates heralded copies of an entangled state between a photonic qubit and a solid-state qubit with a rapid reset time upon failure. The resulting fast rate of entanglement generation is of high utility for heralded quantum networking scenarios involving lossy optical channels.

  20. Fracture of surface cracks loaded in bending

    SciTech Connect (OSTI)

    Chao, Y.J.; Reuter, W.G.

    1997-12-31

    Theoretical background of the constraint effect in brittle fracture of solids is reviewed. Fracture test data from D6-aC, a high strength steel, using three-point-bend (SE(B)) specimens and surface cracked plate (SC(B)) specimens under bending are presented. It is shown that the SE(B) data has an elevated fracture toughness for increasing a/W, i.e., a crack geometry with a larger T/K corresponds to a higher K{sub c} which is consistent with the theoretical prediction. The fundamental fracture properties, i.e., the critical strain and the critical distance, determined from the SE(B) test data are then applied to the interpretation and prediction of the SC(B) test data. Reasonable agreement is achieved for the crack growth initiation site and the load.

  1. Piezoelectric film load cell robot collision detector

    DOE Patents [OSTI]

    Lembke, J.R.

    1988-03-15

    A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are dowelled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector. 3 figs.

  2. Piezoelectric film load cell robot collision detector

    DOE Patents [OSTI]

    Lembke, J.R.

    1989-04-18

    A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are doweled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector. 3 figs.

  3. Piezoelectric film load cell robot collision detector

    DOE Patents [OSTI]

    Lembke, John R. (Overland Park, KS)

    1989-04-18

    A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are dowelled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector.

  4. CRYSTALLINE CERAMIC WASTE FORMS: REFERENCE FORMULATION REPORT

    SciTech Connect (OSTI)

    Brinkman, K.; Fox, K.; Marra, J.

    2012-05-15

    The research conducted in this work package is aimed at taking advantage of the long term thermodynamic stability of crystalline ceramics to create more durable waste forms (as compared to high level waste glass) in order to reduce the reliance on engineered and natural barrier systems. Durable ceramic waste forms that incorporate a wide range of radionuclides have the potential to broaden the available disposal options and to lower the storage and disposal costs associated with advanced fuel cycles. Assemblages of several titanate phases have been successfully demonstrated to incorporate radioactive waste elements, and the multiphase nature of these materials allows them to accommodate variation in the waste composition. Recent work has shown that they can be successfully produced from a melting and crystallization process. The objective of this report is to explain the design of ceramic host systems culminating in a reference ceramic formulation for use in subsequent studies on process optimization and melt property data assessment in support of FY13 melter demonstration testing. The waste stream used as the basis for the development and testing is a combination of the projected Cs/Sr separated stream, the Trivalent Actinide - Lanthanide Separation by Phosphorous reagent Extraction from Aqueous Komplexes (TALSPEAK) waste stream consisting of lanthanide fission products, the transition metal fission product waste stream resulting from the transuranic extraction (TRUEX) process, and a high molybdenum concentration with relatively low noble metal concentrations. In addition to the combined CS/LN/TM High Mo waste stream, variants without Mo and without Mo and Zr were also evaluated. Based on the results of fabricating and characterizing several simulated ceramic waste forms, two reference ceramic waste form compositions are recommended in this report. The first composition targets the CS/LN/TM combined waste stream with and without Mo. The second composition targets with CS/LN/TM combined waste stream with Mo and Zr removed. Waste streams that contain Mo must be produced in reducing environments to avoid Cs-Mo oxide phase formation. Waste streams without Mo have the ability to be melt processed in air. A path forward for further optimizing the processing steps needed to form the targeted phase assemblages is outlined in this report. Processing modifications including melting in a reducing atmosphere, and controlled heat treatment schedules are anticipated to improve the targeted elemental partitioning.

  5. Reference design and operations for deep borehole disposal of high-level radioactive waste.

    SciTech Connect (OSTI)

    Herrick, Courtney Grant; Brady, Patrick Vane; Pye, Steven; Arnold, Bill Walter; Finger, John Travis; Bauer, Stephen J.

    2011-10-01

    A reference design and operational procedures for the disposal of high-level radioactive waste in deep boreholes have been developed and documented. The design and operations are feasible with currently available technology and meet existing safety and anticipated regulatory requirements. Objectives of the reference design include providing a baseline for more detailed technical analyses of system performance and serving as a basis for comparing design alternatives. Numerous factors suggest that deep borehole disposal of high-level radioactive waste is inherently safe. Several lines of evidence indicate that groundwater at depths of several kilometers in continental crystalline basement rocks has long residence times and low velocity. High salinity fluids have limited potential for vertical flow because of density stratification and prevent colloidal transport of radionuclides. Geochemically reducing conditions in the deep subsurface limit the solubility and enhance the retardation of key radionuclides. A non-technical advantage that the deep borehole concept may offer over a repository concept is that of facilitating incremental construction and loading at multiple perhaps regional locations. The disposal borehole would be drilled to a depth of 5,000 m using a telescoping design and would be logged and tested prior to waste emplacement. Waste canisters would be constructed of carbon steel, sealed by welds, and connected into canister strings with high-strength connections. Waste canister strings of about 200 m length would be emplaced in the lower 2,000 m of the fully cased borehole and be separated by bridge and cement plugs. Sealing of the upper part of the borehole would be done with a series of compacted bentonite seals, cement plugs, cement seals, cement plus crushed rock backfill, and bridge plugs. Elements of the reference design meet technical requirements defined in the study. Testing and operational safety assurance requirements are also defined. Overall, the results of the reference design development and the cost analysis support the technical feasibility of the deep borehole disposal concept for high-level radioactive waste.

  6. Measuring Cognitive Load in Multimedia Instruction: A Comparison of Two Instruments

    E-Print Network [OSTI]

    management of such loads. The three types of load identified by CLT include intrinsic load, germane loadMeasuring Cognitive Load in Multimedia Instruction: A Comparison of Two Instruments David Windell March, 2007 Abstract The current study looks to review two popular self-report measures (NASA Task Load

  7. SAPHIRE 8 Volume 2 - Technical Reference

    SciTech Connect (OSTI)

    C. L. Smith; S. T. Wood; W. J. Galyean; J. A. Schroeder; M. B. Sattison

    2011-03-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of computer programs that were developed to create and analyze probabilistic risk assessment (PRAs). Herein information is provided on the principles used in the construction and operation of Version 8.0 of the SAPHIRE system. This report summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms used to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that apply for various assumptions concerning reparability and mission time. It defines the measures of basic event importance that SAPHIRE can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by this program to generate random basic event probabilities from various distributions. Also covered are enhance capabilities such as seismic analysis, Workspace algorithms, cut set "recovery," end state manipulation, and use of "compound events."

  8. Extracting Operating Modes from Building Electrical Load Data: Preprint

    SciTech Connect (OSTI)

    Frank, S.; Polese, L. G.; Rader, E.; Sheppy, M.; Smith, J.

    2012-01-01

    Empirical techniques for characterizing electrical energy use now play a key role in reducing electricity consumption, particularly miscellaneous electrical loads, in buildings. Identifying device operating modes (mode extraction) creates a better understanding of both device and system behaviors. Using clustering to extract operating modes from electrical load data can provide valuable insights into device behavior and identify opportunities for energy savings. We present a fast and effective heuristic clustering method to identify and extract operating modes in electrical load data.

  9. Strategy Guideline. Accurate Heating and Cooling Load Calculations

    SciTech Connect (OSTI)

    Burdick, Arlan

    2011-06-01

    This guide presents the key criteria required to create accurate heating and cooling load calculations and offers examples of the implications when inaccurate adjustments are applied to the HVAC design process. The guide shows, through realistic examples, how various defaults and arbitrary safety factors can lead to significant increases in the load estimate. Emphasis is placed on the risks incurred from inaccurate adjustments or ignoring critical inputs of the load calculation.

  10. Strategy Guideline: Accurate Heating and Cooling Load Calculations

    SciTech Connect (OSTI)

    Burdick, A.

    2011-06-01

    This guide presents the key criteria required to create accurate heating and cooling load calculations and offers examples of the implications when inaccurate adjustments are applied to the HVAC design process. The guide shows, through realistic examples, how various defaults and arbitrary safety factors can lead to significant increases in the load estimate. Emphasis is placed on the risks incurred from inaccurate adjustments or ignoring critical inputs of the load calculation.

  11. 7. Flows in a rotating reference frame 7.1. Rotating reference frames

    E-Print Network [OSTI]

    Read, Peter L.

    in a rotating reference frame. We use rotating axes, fixed w.r.t. the rotating system but note that time-derivatives of vectors must be modified: 1 #12;Suppose frame R rotates at constant angular velocity = (0, 0, ) w.r.t. an inertial frame I. Consider vector A(t) ­ suppose for simplicity that it lies in the xy-plane of R and I

  12. Cooling load differences between radiant and air systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    radiant heating and cooling systems, in: Proceedings ofInc, Altanta,GA, 2009. Cooling load differences betweensurface level 24-hour total cooling energy between radiant

  13. Sandia's research spans generation, storage, and load management at

    E-Print Network [OSTI]

    kW diesel genset, fuel cells, and additional interchangeable generators. Storage capabilities technology integration, microgrid communications, enhanced efficiency, load control, and specialized tests

  14. HVAC Loads in High-Performance Homes (Presentation)

    SciTech Connect (OSTI)

    Christensen, D.; Fang, X.; Winkler, J.

    2010-06-27

    This presentation was delivered at the ASHRAE 2010 Annual Summer Conference on June 27, 2010, and addresses humidity and AC loads in energy efficient houses.

  15. High-Resolution Residential Feeder Load Characterization and...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    been a number of investigations into the effects of PV variability on distribution circuit voltage 1. Due to load data resolution limitations and the difficulty in estimating...

  16. ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM

    E-Print Network [OSTI]

    Krieg, B.

    2010-01-01

    Water Projects Generating Plants and Shiftable Generationfrom "base load" generating plants. ing" and saves energy.Cily flow PUfflj);ng - GeneratIng Plant San LUIS Reservo,,'

  17. Load Expansion of Stoichiometric HCCI Using Spark Assist and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Stoichiometric HCCI Using Spark Assist and Hydraulic Valve Actuation Load Expansion of Stoichiometric HCCI Using Spark Assist and Hydraulic Valve Actuation Presentation given at...

  18. Load Expansion with Diesel/Gasoline RCCI for Improved Engine...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    with DieselGasoline RCCI for Improved Engine Efficiency and Emissions Load Expansion with DieselGasoline RCCI for Improved Engine Efficiency and Emissions This poster will...

  19. Comverge contribution to load participation of ancillary services

    SciTech Connect (OSTI)

    Miyaji, Wendell

    2011-10-25

    Presents Comverge demand response program summary. Discusses advantages of residential aggregation and real-time load management. Compares residential and commercial.

  20. Waste Loading Enhancements for Hanford Low-Activity Waste Glasses

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    WASTE LOADING ENHANCEMENTS FOR HANFORD LOW-ACTIVITY WASTE GLASSES Albert A. Kruger, Glass Scientist DOE-WTP Project Office Engineering Division US Department of Energy Richland,...

  1. Predicting the Response of Electricity Load to Climate Change

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Predicting the Response of Electricity Load to Climate Change Patrick Sullivan, Jesse Colman, and Eric Kalendra National Renewable Energy Laboratory Technical Report NREL...

  2. California Customer Load Reductions during the Electricity Crisis...

    Open Energy Info (EERE)

    California Customer Load Reductions during the Electricity Crisis: Did They Help to Keep the Lights On? Jump to: navigation, search Tool Summary LAUNCH TOOL Name: California...

  3. Prognostic Control and Load Survivability in Shipboard Power Systems 

    E-Print Network [OSTI]

    Thomas, Laurence J.

    2011-02-22

    bus. Generators 2MTG and 2ATG work together to energize loads connected to the port bus. The Forward/Aft Split Bus Mode separates the generators in half forming a left-hand region (fore) and a right hand-region (aft) pairing generators 1MTG and 2... is to maximize the energized loads in case there is a disturbance adhering to constraints of the source node, load node, intermediate node, edge capacity, radiality, and voltage. The results display the capacities of each load and the new path taken to supply...

  4. Retrofitting unreinforced concrete masonry to resist tornado loading

    E-Print Network [OSTI]

    Dorshorst, Evan G. (Evan Gregory)

    2013-01-01

    Advances in structural design and building materials have significantly increased the performance of many structures under the extreme loading conditions associated with natural disasters such as earthquakes. However, ...

  5. Aggregated Modeling and Control of Air Conditioning Loads for...

    Office of Scientific and Technical Information (OSTI)

    Journal Article: Aggregated Modeling and Control of Air Conditioning Loads for Demand Response Citation Details In-Document Search Title: Aggregated Modeling and Control of Air...

  6. NUCLEAR REACTORS; PIPES; SEISMIC EFFECTS; SUPPORTS; DYNAMIC LOADS...

    Office of Scientific and Technical Information (OSTI)

    Limit analysis of pipe clamps Flanders, H.E. Jr. 22 GENERAL STUDIES OF NUCLEAR REACTORS; PIPES; SEISMIC EFFECTS; SUPPORTS; DYNAMIC LOADS; HEAT TRANSFER; HYDRAULICS; REACTOR SAFETY;...

  7. Development and application of the spatially explicit load enrichment calculation tool (select) to determine potential E. coli loads in watersheds 

    E-Print Network [OSTI]

    Riebschleager, Kendra Jean

    2009-05-15

    . coli Load Resulting from Cattle: a) Prior Study (Teague, 2007) and b) Automated. ......................................... 65 Figure 3.5. Difference in Potential E. coli Load Resulting from Wildlife a) Feral Hogs (Teague, 2007), b) Feral Hogs (This... study), c) Deer (Teague, 2007), d) Deer (This study)................................................ 66 Figure 3.6. Difference in Potential E. coli Loads from Feral Hogs Between Previous Study and This Study...

  8. International linear collider reference design report

    SciTech Connect (OSTI)

    Aarons, G.

    2007-06-22

    The International Linear Collider will give physicists a new cosmic doorway to explore energy regimes beyond the reach of today's accelerators. A proposed electron-positron collider, the ILC will complement the Large Hadron Collider, a proton-proton collider at the European Center for Nuclear Research (CERN) in Geneva, Switzerland, together unlocking some of the deepest mysteries in the universe. With LHC discoveries pointing the way, the ILC -- a true precision machine -- will provide the missing pieces of the puzzle. Consisting of two linear accelerators that face each other, the ILC will hurl some 10 billion electrons and their anti-particles, positrons, toward each other at nearly the speed of light. Superconducting accelerator cavities operating at temperatures near absolute zero give the particles more and more energy until they smash in a blazing crossfire at the centre of the machine. Stretching approximately 35 kilometres in length, the beams collide 14,000 times every second at extremely high energies -- 500 billion-electron-volts (GeV). Each spectacular collision creates an array of new particles that could answer some of the most fundamental questions of all time. The current baseline design allows for an upgrade to a 50-kilometre, 1 trillion-electron-volt (TeV) machine during the second stage of the project. This reference design provides the first detailed technical snapshot of the proposed future electron-positron collider, defining in detail the technical parameters and components that make up each section of the 31-kilometer long accelerator. The report will guide the development of the worldwide R&D program, motivate international industrial studies and serve as the basis for the final engineering design needed to make an official project proposal later this decade.

  9. Report of the US Nuclear Regulatory Commission Piping Review Committee. Volume 4. Evaluation of other loads and load combinations

    SciTech Connect (OSTI)

    Not Available

    1984-12-01

    Six topical areas were covered by the Task Group on Other Dynamic Loads and Load Combinations as described below: Event Combinations - dealing with the potential simultaneous occurrence of earthquakes, pipe ruptures, and water hammer events in the piping design basis; Response Combinations - dealing with multiply supported piping with independent inputs, the sequence of combinations between spacial and modal components of response, and the treatment of high frequency modes in combination with low frequency modal responses; Stress Limits/Dynamic Allowables - dealing with inelastic allowables for piping and strain rate effects; Water Hammer Loadings - dealing with code and design specifications for these loadings and procedures for identifying potential water hammer that could affect safety; Relief Valve Opening and Closing Loads - dealing with the adequacy of analytical tools for predicting the effects of these events and, in addition, with estimating effective cycles for fatigue evaluations; and Piping Vibration Loads - dealing with evaluation procedures for estimating other than seismic vibratory loads, the need to consider reciprocating and rotary equipment vibratory loads, and high frequency vibratory loads. NRC staff recommendations or regulatory changes and additional study appear in this report.

  10. Lithium Loaded Glass Fiber Neutron Detector Tests

    SciTech Connect (OSTI)

    Ely, James H.; Erikson, Luke E.; Kouzes, Richard T.; Lintereur, Azaree T.; Stromswold, David C.

    2009-11-12

    Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world and, thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of the lithium-loaded glass fibers option. This testing measured the neutron detection efficiency and gamma ray rejection capabilities of a small system manufactured by Nucsafe (Oak Ridge, TN).

  11. How loads affect coiled tubing life

    SciTech Connect (OSTI)

    Walker, E.J. Inc., AK )

    1992-01-01

    Fatigue testing was performed on 1-3/4-in OD, 0.125 in. wall thickness (WT) coiled tubing using a standard coiled tubing unit (CTU) as shown in this paper. Testing was conducted under Prudhoe Bay, Alaska oil well, conditions to determine the effects of axial load, internal pressure and bending stress on the longevity, or usable running footage, that can be expected with larger diameter tubing. The CTU was rigged up in a standard configuration with injector head 50 ft off the ground, the worst case for bending on most currently available North Slope units. Internal pressure was supplied by a small triplex pump and the end of tubing was closed off with a fishing neck and bull plug. Weight, for the first four tests, was suspended from the coiled tubing by a special clamp. The tubing was cycled up and over the guide arch until a loss of internal coiled tubing pressure (CTP) occurred, or until the tubing became stuck in the stripper brass.

  12. Apparatus for loading shape memory gripper mechanisms

    DOE Patents [OSTI]

    Lee, Abraham P. (Walnut Creek, CA); Benett, William J. (Livermore, CA); Schumann, Daniel L. (Concord, CA); Krulevitch, Peter A. (Pleasanton, CA); Fitch, Joseph P. (Livermore, CA)

    2001-01-01

    A method and apparatus for loading deposit material, such as an embolic coil, into a shape memory polymer (SMP) gripping/release mechanism. The apparatus enables the application of uniform pressure to secure a grip by the SMP mechanism on the deposit material via differential pressure between, for example, vacuum within the SMP mechanism and hydrostatic water pressure on the exterior of the SMP mechanism. The SMP tubing material of the mechanism is heated to above the glass transformation temperature (Tg) while reshaping, and subsequently cooled to below Tg to freeze the shape. The heating and/or cooling may, for example, be provided by the same water applied for pressurization or the heating can be applied by optical fibers packaged to the SMP mechanism for directing a laser beam, for example, thereunto. At a point of use, the deposit material is released from the SMP mechanism by reheating the SMP material to above the temperature Tg whereby it returns to its initial shape. The reheating of the SM material may be carried out by injecting heated fluid (water) through an associated catheter or by optical fibers and an associated beam of laser light, for example.

  13. Exploiting Home Automation Protocols for Load Monitoring in Smart Buildings

    E-Print Network [OSTI]

    Massachusetts at Amherst, University of

    @cs.williams.edu Abstract Monitoring and controlling electrical loads is crucial for demand-side energy management in smart their use in load monitoring. In this paper, we highlight challenges in de- signing AutoMeter, a system]: Miscella- neous; K.6.2 [Management of Computing and Informa- tion Systems]: Installation Management

  14. Dynamic Transfer Capability Analysis with Wind Farms and Dynamic Loads

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    . An investigation on the effect of dynamics loads, wind farms and flexible AC transmission system (FACTS) devices capability unnecessarily limits the power transfers and is a costly and inefficient use of a network with increasing loads, the need to transfer power over long transmission lines increases. Deregulation

  15. Ris-R-1111(EN) Ultimate Loading of Wind Turbines

    E-Print Network [OSTI]

    Risř-R-1111(EN) Ultimate Loading of Wind Turbines Gunner Chr. Larsen, Knut Ronold, Hans E-R-1111(EN) 2 Abstract An extreme loading study has been conducted comprising a general wind climate analysis as well as a wind turbine reliability study. In the wind climate analysis, the distribution

  16. Detection of Periodic Beacon Loads in Electrical Distribution Substation Data

    SciTech Connect (OSTI)

    Hammerstrom, Donald J.; Guttromson, Ross T.; Lu, Ning; Boyd, Paul A.; Trudnowski, Daniel; Chassin, David P.; Bonebrake, Christopher A.; Shaw, James M.

    2006-05-31

    This research explores methods for identifying a whether a load is sending a signal to the utility SCADA system. Such a system can identify whether various loads are signialing using existing SCADA infrastructure, that is, without added, high cost communications infrastructure.

  17. Retention of Riverine Sediment and Nutrient Loads by Coastal Plain

    E-Print Network [OSTI]

    Retention of Riverine Sediment and Nutrient Loads by Coastal Plain Floodplains Gregory B. Noe for their cumulative retention of the annual river loads of nutrients or sediments. Here we report measurements of sediment accretion and associated carbon, nitrogen, and phosphorus accu- mulation as sedimentation over

  18. Distributional Analysis for Model Predictive Deferrable Load Control

    E-Print Network [OSTI]

    Low, Steven H.

    for demand response. There are two major categories of demand response, direct load control (DLC) and price-based demand response. See [1] for a discussion of the contrasts between these approaches. In this paper we focus on direct load control with the goal of using demand response to reduce variations

  19. Cone Penetrometer Load Cell Temperature and Radiation Testing Results

    SciTech Connect (OSTI)

    Follett, Jordan R.

    2013-08-28

    This report summarizes testing activities performed at the Pacific Northwest National Laboratory to verify the cone penetrometer load cell can withstand the tank conditions present in 241-AN-101 and 241-AN-106. The tests demonstrated the load cell device will operate under the elevated temperature and radiation levels expected to be encountered during tank farm deployment of the device.

  20. Topological design solutions for structures under transmissible loads

    E-Print Network [OSTI]

    Fuchs, Moshe

    . It will be noted that in many solutions one can discern a marked difference between the underlying load­bearing) elements whose basic task is to transfer the applied forces to the load­bearing part of the assembly. The main purpose of the present work is to induce the algorithm to produce the 'structural' part

  1. Structural evaluation of the 2736Z Building for seismic loads

    SciTech Connect (OSTI)

    Giller, R.A.

    1994-09-23

    The 2736Z building structure is evaluated for high-hazard loads. The 2736Z building is analyzed herein for normal and seismic loads and is found to successfully meet the guidelines of UCRL-15910 along with the related codes requirements.

  2. Structural load inventory database for the Kansas City federal complex

    SciTech Connect (OSTI)

    Hashimoto, P.S.; Johnson, M.W.; Nakaki, D.K. [EQE International, Inc., Irvine, CA (United States); Lynch, D.T.; Drury, M.A. [AlliedSignal Inc., Kansas City, MO (United States). Kansas City Division

    1995-12-01

    A structural load inventory database (LID) has been developed to support configuration management at the DOE Kansas City Plant (KCP). The objective of the LID is to record loads supported by the plant structures and to provide rapid assessments of the impact of future facility modifications on structural adequacy. Development of the LID was initiated for the KCP`s Main Manufacturing Building. Field walkdowns were performed to determine all significant loads supported by the structure, including the weight of piping, service equipment, etc. These loads were compiled in the LID. Structural analyses for natural phenomena hazards were performed in accordance with UCRL-15910. Software to calculate demands on the structural members due to gravity loads, total demands including both gravity and seismic loads, and structural member demand-to-capacity ratios were also developed and integrated into the LID. Operation of the LID is menu-driven. The LID user has options to review and print existing loads and corresponding demand-to-capacity ratios, and to update the supported loads and demand-to-capacity ratios for any future facility modifications.

  3. Comparison of Building Energy Modeling Programs: Building Loads

    E-Print Network [OSTI]

    LBNL-6034E Comparison of Building Energy Modeling Programs: Building Loads Dandan Zhu1 , Tianzhen Energy, the U.S.-China Clean Energy Research Center for Building Energy Efficiency, of the U;Comparison of Building Energy Modeling Programs: Building Loads A joint effort between Lawrence Berkeley

  4. Ten Steps for Career Success Ready Reference A-4

    E-Print Network [OSTI]

    Ten Steps for Career Success Ready Reference A-4 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career

  5. Sample Letter of Inquiry Ready Reference F-4

    E-Print Network [OSTI]

    Sample Letter of Inquiry Ready Reference F-4 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career

  6. First Impressions on Job Interviews Ready Reference G-2

    E-Print Network [OSTI]

    & Technology Career Services Oklahoma State University College of Engineering, Architecture & TechnologyFirst Impressions on Job Interviews Ready Reference G-2 College of Engineering, Architecture

  7. Sample Status Inquiry Letter Ready Reference F-9

    E-Print Network [OSTI]

    Sample Status Inquiry Letter Ready Reference F-9 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology

  8. Bibliography of the Scripps Institution of Oceanography Reference Series 2000

    E-Print Network [OSTI]

    Criqui, Nan P.

    2001-01-01

    SCRIPPS INSTITUTION OF OCEANOGRAPHY REFERENCE SERIES 00-1.Emeritus professor of oceanography, SIO, UCSD. ( OralScripps Institution of Oceanography. March 2000. 80p. 00-5.

  9. Bibliography of the Scripps Institution of Oceanography Reference Series 1999

    E-Print Network [OSTI]

    Jennings, Paige A.

    2000-01-01

    SCRIPPS INSTITUTION OF OCEANOGRAPHY REFERENCE SERIES 99-1Scripps Institution of Oceanography. April 1999. 55p. 99-11the Scripps Institution of Oceanography. Originally printed

  10. Bibliography of the Scripps Institution of Oceanography Reference Series 2002

    E-Print Network [OSTI]

    Lett, Phyllis C.

    2003-01-01

    Scripps Institution of Oceanography Reference Series. MarchSCRIPPS INSTITUTION OF OCEANOGRAPHY LA JOLL~ CALIFORNIAOF THE SCRIPPS INSTITUTION OF OCEANOGRAPHY REF ERENCE SERIES

  11. Bibliography of the Scripps Institution of Oceanography Reference Series 1995

    E-Print Network [OSTI]

    Criqui, Nan P.

    1995-01-01

    Scripps Institution of Oceanography. August 1995. 353p. 95-OF THE SCRIPPS INSTITUTION OF OCEANOGRAPHY REFERENCE SERIESScripps Institution of Oceanography. January 1995. 10p. Day,

  12. Existing Commercial Reference Buildings Constructed In or After 1980 — Archive

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location.

  13. MPI: The Complete Reference Scientific and Engineering Computation

    E-Print Network [OSTI]

    Lu, Paul

    MPI: The Complete Reference #12; Scientific and Engineering Computation Janusz Kowalik, Editor Data Manchek, and Vaidy Sunderam, 1994 Enabling Technologies for Petaflops Computing by Thomas Sterling, Paul

  14. Reference Model for Control and Automation Systems in Electrical...

    Office of Environmental Management (EM)

    Reference Model for Control and Automation Systems in Electrical Power Version 1.2 October 12, 2005 Prepared by: Sandia National Laboratories' Center for SCADA Security Jason...

  15. Reference Model for Control and Automation Systems in Electrical...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Model for Control and Automation Systems in Electrical Power (October 2005) Reference Model for Control and Automation Systems in Electrical Power (October 2005) Modern...

  16. H2FIRST Reference Station Design Task: Project Deliverable 2...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    98 List of Tables Table ES-1. Station Types Selected for Detailed Reference Design Development ... v Table 1. Changed Input Parameters...

  17. Plutonium Certified Reference Materials Price List | U.S. DOE...

    Office of Science (SC) Website

    Laboratory (NBL) NBL Home About Programs Certified Reference Materials (CRMs) Prices and Certificates Ordering Information Training NEPA Documents News Safety Data Sheets...

  18. NERSC/DOE FES Requirements Workshop Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Materials Reference Materials Large Scale Computing and Storage Requirements for Fusion Energy Sciences August 3-4, 2010 Official DOE Invitation Workshop Invitation Letter from...

  19. FAQS Reference Guide – Safeguards and Security General Technical Base

    Office of Energy Efficiency and Renewable Energy (EERE)

    This reference guide addresses the competency statements in the July 2009 edition of DOE-STD-1123-2009, Safeguards and Security General Technical Base Qualification Standard.

  20. Sandia Energy - Floating Oscillating Water Column Reference Model...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to provide publicly available technical and economic benchmarks for a variety of marine energy converters. The final reference model, an oscillating water column (OWC)...

  1. Design-Load Basis for LANL Structures, Systems, and Components

    SciTech Connect (OSTI)

    I. Cuesta

    2004-09-01

    This document supports the recommendations in the Los Alamos National Laboratory (LANL) Engineering Standard Manual (ESM), Chapter 5--Structural providing the basis for the loads, analysis procedures, and codes to be used in the ESM. It also provides the justification for eliminating the loads to be considered in design, and evidence that the design basis loads are appropriate and consistent with the graded approach required by the Department of Energy (DOE) Code of Federal Regulation Nuclear Safety Management, 10, Part 830. This document focuses on (1) the primary and secondary natural phenomena hazards listed in DOE-G-420.1-2, Appendix C, (2) additional loads not related to natural phenomena hazards, and (3) the design loads on structures during construction.

  2. Predicting the Response of Electricity Load to Climate Change

    SciTech Connect (OSTI)

    Sullivan, Patrick; Colman, Jesse; Kalendra, Eric

    2015-07-28

    Our purpose is to develop a methodology to quantify the impact of climate change on electric loads in the United States. We perform simple linear regression, assisted by geospatial smoothing, on paired temperature and load time-series to estimate the heating- and coolinginduced sensitivity to temperature across 300 transmission zones and 16 seasonal and diurnal time periods. The estimated load sensitivities can be coupled with climate scenarios to quantify the potential impact of climate change on load, with a primary application being long-term electricity scenarios. The method allows regional and seasonal differences in climate and load response to be reflected in the electricity scenarios. While the immediate product of this analysis was designed to mesh with the spatial and temporal resolution of a specific electricity model to enable climate change scenarios and analysis with that model, we also propose that the process could be applied for other models and purposes.

  3. Recovery Act. Advanced Load Identification and Management for Buildings

    SciTech Connect (OSTI)

    Yang, Yi; Casey, Patrick; Du, Liang; He, Dawei

    2014-02-12

    In response to the U.S. Department of Energy (DoE)’s goal of achieving market ready, net-zero energy residential and commercial buildings by 2020 and 2025, Eaton partnered with the Department of Energy’s National Renewable Energy Laboratory (NREL) and Georgia Institute of Technology to develop an intelligent load identification and management technology enabled by a novel “smart power strip” to provide critical intelligence and information to improve the capability and functionality of building load analysis and building power management systems. Buildings account for 41% of the energy consumption in the United States, significantly more than either transportation or industrial. Within the building sector, plug loads account for a significant portion of energy consumption. Plug load consumes 15-20% of building energy on average. As building managers implement aggressive energy conservation measures, the proportion of plug load energy can increase to as much as 50% of building energy leaving plug loads as the largest remaining single source of energy consumption. This project focused on addressing plug-in load control and management to further improve building energy efficiency accomplished through effective load identification. The execution of the project falls into the following three major aspects; An intelligent load modeling, identification and prediction technology was developed to automatically determine the type, energy consumption, power quality, operation status and performance status of plug-in loads, using electric waveforms at a power outlet level. This project demonstrated the effectiveness of the developed technology through a large set of plug-in loads measurements and testing; A novel “Smart Power Strip (SPS) / Receptacle” prototype was developed to act as a vehicle to demonstrate the feasibility of load identification technology as a low-cost, embedded solution; and Market environment for plug-in load control and management solutions, in particular, advanced power strips (APSs) was studied. The project evaluated the market potential for Smart Power Strips (SPSs) with load identification and the likely impact of a load identification feature on APS adoption and effectiveness. The project also identified other success factors required for widespread APS adoption and market acceptance. Even though the developed technology is applicable for both residential and commercial buildings, this project is focused on effective plug-in load control and management for commercial buildings, accomplished through effective load identification. The project has completed Smart Receptacle (SR) prototype development with integration of Load ID, Control/Management, WiFi communication, and Web Service. Twenty SR units were built, tested, and demonstrated in the Eaton lab; eight SR units were tested in the National Renewable Energy Lab (NREL) for one-month of field testing. Load ID algorithm testing for extended load sets was conducted within the Eaton facility and at local university campuses. This report is to summarize the major achievements, activities, and outcomes under the execution of the project.

  4. Adhesion clusters under shared linear loading: a stochastic analysis

    E-Print Network [OSTI]

    T. Erdmann; U. S. Schwarz

    2004-03-22

    We study the cooperative rupture of multiple adhesion bonds under shared linear loading. Simulations of the appropriate Master equation are compared with numerical integration of a rate equation for the mean number of bonds and its scaling analysis. In general, force-accelerated rupture is rather abrupt. For small clusters and slow loading, large fluctuations occur regarding the timepoint of final rupture, but not the typical shape of the rupture trajectory. For vanishing rebinding, our numerical results confirm three scaling regimes predicted before for cluster lifetime as a function of loading rate. For finite rebinding, the intermediate loading regime becomes irrelevant, and a sequence of two new scaling laws can be identified in the slow loading regime.

  5. Short-Term Load Forecasting This paper discusses the state of the art in short-term load fore-

    E-Print Network [OSTI]

    Gross, George

    spectrum of time intervals. In therange of seconds, when load variationsare small and random, the automatic by a number of generation control functions such as hydro scheduling, unit commitment, hydro-ther- mal present, functions such as fuel, hydro, and maintenance scheduling are performed to ensure that the load

  6. Empowering the Frontline: A Dynamic Online Reference Manual and Training Session for Student Library Employee Reference Skills

    E-Print Network [OSTI]

    Loo, Jeffery L; Quigley, Brian D; Ngo, Lisa T; Powell, Susan; Teplitzky, Samantha

    2015-01-01

    training across our libraries’ service points. To developSession for Student Library Employee Reference SkillsTraining Design 5 libraries Engineering & Physical Sciences

  7. Archived Reference Building Type: Stand-alone retail

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  8. Archived Reference Building Type: Stand-alone retail

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  9. Archived Reference Climate Zone: 3C San Francisco, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  10. Archived Reference Climate Zone: 3C San Francisco, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  11. Archived Reference Climate Zone: 4A Baltimore, Maryland

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  12. Archived Reference Climate Zone: 4A Baltimore, Maryland

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  13. SQL Reference Learning Gupta SQLBase Structured Query Language

    E-Print Network [OSTI]

    SQL Reference Learning Gupta SQLBase Structured Query Language (SQL) By William Sprouse CENTER, CO 80523 Spring 1996 #12;SQL Reference Learning Gupta SQLBase Structured Query Language (SQL.1.2.4 The Clipboard 5 2.2 GETTING STARTED 5 2.2.1 STARTING QUEST 5 2.2.2 GETTING HELP 6 3. SQL BASICS 6 3

  14. DEGAS 2 Verification Test with Fluid Neutral Momentum Transport Reference

    E-Print Network [OSTI]

    Budny, Robert

    DEGAS 2 Verification Test with Fluid Neutral Momentum Transport Reference Problem D. P. Stotler, PPPL 1 Background The "Fluid Neutral Momentum Transport Reference Problem" [1] was used to verify the original DEGAS [2] Monte Carlo neutral transport code. The resulting benchmark was subsequently employed

  15. Archived Reference Climate Zone: 6A Minneapolis, Minnesota

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Climate Zone: 6A Minneapolis, Minnesota

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  17. NIST STANDARD REFERENCE DATA (SRD) INTERNET SERVICE SUBSCRIPTION LICENSE

    E-Print Network [OSTI]

    NIST STANDARD REFERENCE DATA (SRD) INTERNET SERVICE SUBSCRIPTION LICENSE This document is a non-exclusive, non-transferrable, non-assignable and limited License Agreement (AGREEMENT) between the National ­ a person designated in the License to use the Internet Edition of a NIST Standard Reference Database under

  18. Dynamic Stochastic Inventory Management with Reference Price Effects

    E-Print Network [OSTI]

    Chen, Xin

    Dynamic Stochastic Inventory Management with Reference Price Effects Xin Chen Department in which demand depends on not only the current selling price but also a memory-based reference price. Pricing and inventory decisions are made simultane- ously at the beginning of each period. Assuming all

  19. Archived Reference Climate Zone: 2B Phoenix, Arizona

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  20. Archived Reference Climate Zone: 2B Phoenix, Arizona

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  1. Multi-State Load Models for Distribution System Analysis

    SciTech Connect (OSTI)

    Schneider, Kevin P.; Fuller, Jason C.; Chassin, David P.

    2011-11-01

    Recent work in the field of distribution system analysis has shown that the traditional method of peak load analysis is not adequate for the analysis of emerging distribution system technologies. Voltage optimization, demand response, electric vehicle charging, and energy storage are examples of technologies with characteristics having daily, seasonal, and/or annual variations. In addition to the seasonal variations, emerging technologies such as demand response and plug in electric vehicle charging have the potential to send control signals to the end use loads which will affect how they consume energy. In order to support time-series analysis over different time frames and to incorporate potential control signal inputs it is necessary to develop detailed end use load models which accurately represent the load under various conditions, and not just during the peak load period. This paper will build on previous work on detail end use load modeling in order to outline the method of general multi-state load models for distribution system analysis.

  2. Experimental evaluation of rotary engine timing gear loads

    SciTech Connect (OSTI)

    Kulina, M.R.

    1986-01-01

    The function of the timing gear of a rotary engine is to control the angular velocity of the rotor in relation to that of the crankshaft. The only load on the gear consists of the friction load due to the rotor seals, the torsional motion of the rotor and any torque developed on the rotor caused by uneven pressure distribution across the rotor flank. In the design of the gear and attachments an estimate of the loads must be made. In the case of an aircraft engine, knowing the actual loads and designing accordingly would result in the most weight effective configuration. A specially instrumented stationary gear of a Deere 0.67 liter SCORE III rotary engine was used to measure the peak torque during test stand operation. The results of the test confirm that rotor friction and torsional motion (due to drive line dynamics) produce the prime gear load below 70% design speed. At the higher engine speeds, a sub-system resonance of the rotor contributes significantly to the total load on the gear. The results of this test, together with the results of three earlier tests conducted on stationary gears are used to establish a design guide. This design guide relates the stationary gear load to crankshaft mean torque and engine displacement.

  3. Seismic Loading for FAST: May 2011 - August 2011

    SciTech Connect (OSTI)

    Asareh, M. A.; Prowell, I.

    2012-08-01

    As more wind farms are constructed in seismically active regions, earthquake loading increases in prominence for design and analysis of wind turbines. Early investigation of seismic load tended to simplify the rotor and nacelle as a lumped mass on top of the turbine tower. This simplification allowed the use of techniques developed for conventional civil structures, such as buildings, to be easily applied to wind turbines. However, interest is shifting to more detailed models that consider loads for turbine components other than the tower. These improved models offer three key capabilities in consideration of base shaking for turbines: 1) The inclusion of aerodynamics and turbine control; 2) The ability to consider component loads other than just tower loads; and 3) An improved representation of turbine response in higher modes by reducing modeling simplifications. Both experimental and numerical investigations have shown that, especially for large modern turbines, it is important to consider interaction between earthquake input, aerodynamics, and operational loads. These investigations further show that consideration of higher mode activity may be necessary in the analysis of the seismic response of turbines. Since the FAST code is already capable of considering these factors, modifications were developed that allow simulation of base shaking. This approach allows consideration of this additional load source within a framework, the FAST code that is already familiar to many researchers and practitioners.

  4. Communication between inertial observers with partially correlated reference frames

    E-Print Network [OSTI]

    Mehdi Ahmadi; Alexander R. H. Smith; Andrzej Dragan

    2015-08-13

    In quantum communication protocols the existence of a shared reference frame between two spatially separated parties is normally presumed. However, in many practical situations we are faced with the problem of misaligned reference frames. In this paper, we study communication between two inertial observers who have partial knowledge about the Lorentz transformation that relates their frames of reference. Since every Lorentz transformation can be decomposed into a pure boost followed by a rotation, we begin by analysing the effects on communication when the parties have partial knowledge about the transformation relating their frames, when the transformation is either a rotation or pure boost. This then enables us to investigate how the efficiency of communication is affected due to partially correlated inertial reference frames related by an arbitrary Lorentz transformation. Furthermore, we show how the results of previous studies where reference frames are completely uncorrelated are recovered from our results in appropriate limits.

  5. Aerosol penetration through a seismically loaded shear wall

    SciTech Connect (OSTI)

    Farrar, C.R.; Girrens, S.P.

    1992-05-01

    An experimental study was performed to measure the aerosol penetration through a reinforced concrete shear wall after simulated seismic damage. Static load-cycle testing, to stress levels sufficient to induce visible shear cracking, was used to simulate the earthquake loading. Air permeability tests were performed both before and after the simulated seismic loading damaged the structure. Aerosol penetration measurements were conducted on the cracked shear wall structure using 0.10 {mu}m monodisperse particles. The measured aerosol number penetration through the cracked shear wall was 0.5%. 7 refs.

  6. Aerosol penetration through a seismically loaded shear wall

    SciTech Connect (OSTI)

    Farrar, C.R.; Girrens, S.P.

    1992-01-01

    An experimental study was performed to measure the aerosol penetration through a reinforced concrete shear wall after simulated seismic damage. Static load-cycle testing, to stress levels sufficient to induce visible shear cracking, was used to simulate the earthquake loading. Air permeability tests were performed both before and after the simulated seismic loading damaged the structure. Aerosol penetration measurements were conducted on the cracked shear wall structure using 0.10 {mu}m monodisperse particles. The measured aerosol number penetration through the cracked shear wall was 0.5%. 7 refs.

  7. Electromagnetic fields in nonuniform disk-loaded waveguides

    E-Print Network [OSTI]

    Ayzatsky, M I

    2015-01-01

    On the base of general approach we obtain some results that can be useful in the process of tuning of nonunifrom disc-loaded waveguides. Our consideration has shown that simple values that characterize the detuning of the cells can be introduced only for the disc-loaded waveguide with parameters that change very slow. In general case it is needed to conduct full numerical simulation of specific disc-loaded waveguide and obtain all necessary coupling coefficients. After that one can start the tuning process on the base of bead-pull field distribution measurements.

  8. D0 Silicon Upgrade: Lower Cleanroom Roof Quick Load Analysis

    SciTech Connect (OSTI)

    Rucinski, Russ; /Fermilab

    1995-11-17

    This engineering note documents calculations done to determine the margin of safety for the lower clean room roof. The analysis was done to give me a feeling of what the loads, stresses and capacity of the roof is prior to installation and installation work to be done for the helium refrigerator upgrade. The result of this quick look showed that the calculated loads produce stress values and loads at about half the allowables. Based on this result, I do not think that special precautions above personal judgement are required for the installation work.

  9. Loads Providing Ancillary Services: Review of International Experience

    SciTech Connect (OSTI)

    Heffner, Grayson; Goldman, Charles; Kintner-Meyer, Michael

    2007-05-01

    In this study, we examine the arrangements for and experiences of end-use loads providing ancillary services (AS) in five electricity markets: Australia, the United Kingdom (UK), the Nordic market, and the ERCOT and PJM markets in the United States. Our objective in undertaking this review of international experience was to identify specific approaches or market designs that have enabled customer loads to effectively deliver various ancillary services (AS) products. We hope that this report will contribute to the ongoing discussion in the U.S. and elsewhere regarding what institutional and technical developments are needed to ensure that customer loads can meaningfully participate in all wholesale electricity markets.

  10. Published in Proceedings of the XL2003 (Response of Structures to Extreme Loading) Conference, Toronto, August 2003. EFFICIENT MODELS FOR WIND TURBINE EXTREME LOADS

    E-Print Network [OSTI]

    Manuel, Lance

    , Toronto, August 2003. EFFICIENT MODELS FOR WIND TURBINE EXTREME LOADS USING INVERSE RELIABILITY K, USA ABSTRACT The reliability of wind turbines against extreme loads is the focus of this study loads for a 600kW three-bladed horizontal-axis wind turbine. Only operating loads ­ here, flapwise (out

  11. MAC -OUTLOOK QUICK TIP REFERENCE GUIDE 1 Quick Tip Reference Guide | Swinburne University of Technology Version 1.0

    E-Print Network [OSTI]

    Liley, David

    MAC - OUTLOOK QUICK TIP REFERENCE GUIDE 1 Quick Tip Reference Guide | Swinburne University of Technology Version 1.0 Managing Your Emails Conversation View in Outlook 2011 1. Click Organize tab 2. Click. On the Outlook menu, click Preferences. 2. Under E-mail, click Signatures . 3. Click Default Signatures. 4. Under

  12. Blue carbon storage potential of marine carbonate deposits Project reference IAP/13/50. Please quote this reference when applying.

    E-Print Network [OSTI]

    Guo, Zaoyang

    IAPETUS Blue carbon storage potential of marine carbonate deposits Project reference IAP/13 Henrik Stahl, Scottish Association for Marine Science Key Words 1. Blue carbon 2. Carbonate 3. Coralline is referred to as `blue carbon' to differentiate it from terrestrial carbon stores. Known blue carbon sinks

  13. Shipboard applications of non-intrusive load monitoring

    E-Print Network [OSTI]

    Ramsey, Jack S

    2004-01-01

    The Non-Intrusive Load Monitor (NILM) provides a method of measuring component performance and source power quality through a single point of entry in the power distribution system. A study was performed utilizing the NILM ...

  14. Potential Peak Load Reductions From Residential Energy Efficient Upgrades 

    E-Print Network [OSTI]

    Meisegeier, D.; Howes, M.; King, D.; Hall, J.

    2002-01-01

    the potential peak load reductions from residential energy efficiency upgrades in hot and humid climates. First, a baseline scenario is established. Then, the demand and consumption impacts of individual upgrade measures are assessed. Several of these upgrades...

  15. Laser ablation loading of a surface-electrode ion trap

    E-Print Network [OSTI]

    David R. Leibrandt; Robert J. Clark; Jaroslaw Labaziewicz; Paul Antohi; Waseem Bakr; Kenneth R. Brown; Isaac L. Chuang

    2007-06-22

    We demonstrate loading by laser ablation of $^{88}$Sr$^+$ ions into a mm-scale surface-electrode ion trap. The laser used for ablation is a pulsed, frequency-tripled Nd:YAG with pulse energies of 1-10 mJ and durations of 3-5 ns. An additional laser is not required to photoionize the ablated material. The efficiency and lifetime of several candidate materials for the laser ablation target are characterized by measuring the trapped ion fluorescence signal for a number of consecutive loads. Additionally, laser ablation is used to load traps with a trap depth (40 meV) below where electron impact ionization loading is typically successful ($\\gtrsim$ 500 meV).

  16. Review of Residential Low-Load HVAC Systems

    SciTech Connect (OSTI)

    Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

    2013-09-01

    In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

  17. Response of Lithium Polymer Batteries to Mechanical Loading

    E-Print Network [OSTI]

    Petta, Jason

    Response of Lithium Polymer Batteries to Mechanical Loading Karl Suabedissen1, Christina Peabody2 #12;Outline · Motivation · Battery Structure · Testing and Results · Conclusions #12;Motivation · Lithium polymer batteries are everywhere. · Efforts to create flexible batteries. · Restrictive battery

  18. An Innovative Approach Towards National Peak Load Management 

    E-Print Network [OSTI]

    Al-Mulla, A.; Maheshwari, G. P.; Al-Nakib, D.; ElSherbini, A.; Alghimlas, F.; Al-Taqi, H.; Al-Hadban, Y.

    2008-01-01

    An innovative approach was developed and implemented in eight governmental buildings to reduce their load during the peak demand hours in summer of 2007. The innovative approach implemented in these buildings included pre-closing treatment (PCT...

  19. Adaptive load control of microgrids with non-dispatchable generation

    E-Print Network [OSTI]

    Brokish, Kevin Martin

    2009-01-01

    Intelligent appliances have a great potential to provide energy storage and load shedding for power grids. Microgrids are simulated with high levels of wind energy penetration. Frequency-adaptive intelligent appliances are ...

  20. On Load Balancing in a Dense Wireless Multihop Network

    E-Print Network [OSTI]

    Hyytiä, Esa

    3000, FIN 02015 TKK, Finland Abstract-- We study the load balancing problem in a dense wireless Research Center and by the Academy of Finland (grant n:o 202204). maximum is not a topic of this paper

  1. CoolCab Truck Thermal Load Reduction | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    in Bethesda, Maryland. merit08proc.pdf More Documents & Publications CoolCab Truck Thermal Load Reduction CoolCab Test and Evaluation and CoolCalc HVAC Tool Development CoolCab...

  2. Improving Efficiency and Load Range of Boosted HCCI using Partial...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of gasoline-fueled HCCI. - Achieved loads up to 16.3 bar IMEP without engine knock & ultra-low NO X . g - Knock controlled by retarding combustion phasing. z Improvements are...

  3. ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM

    E-Print Network [OSTI]

    Krieg, B.

    2010-01-01

    Shiftable Pumping Load for the State Water Project at FullAlternative Futures The State Water Project LIST OF TABLESTable 10 Present and Projected Water Requirements by Use and

  4. CBEI - Virtual Refrigerant Charge Sensing and Load Metering

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    (system definition) Accomplishments - Water-Side Load Metering Swope School of Music Cooling Season Results (AHU-7) July15 - July 21, 2014 (Period 2) Daily -2.6% 2.0%...

  5. Energy efficiency indicators for high electric-load buildings

    SciTech Connect (OSTI)

    Aebischer, Bernard; Balmer, Markus A.; Kinney, Satkartar; Le Strat, Pascale; Shibata, Yoshiaki; Varone, Frederic

    2003-06-01

    Energy per unit of floor area is not an adequate indicator for energy efficiency in high electric-load buildings. For two activities, restaurants and computer centres, alternative indicators for energy efficiency are discussed.

  6. NREL EFM DATA: Disaggregated Residential Load Cost Data - Datasets...

    Open Energy Info (EERE)

    miscellaneous electric load plugs, and appliances found in "common households" given by costs broken out by months. All data within each cell is a floating point number with the...

  7. Hanford Apatite Treatability Test Report Errata: Apatite Mass Loading Calculation

    SciTech Connect (OSTI)

    Szecsody, James E.; Vermeul, Vincent R.; Williams, Mark D.; Truex, Michael J.

    2014-05-19

    The objective of this errata report is to document an error in the apatite loading (i.e., treatment capacity) estimate reported in previous apatite treatability test reports and provide additional calculation details for estimating apatite loading and barrier longevity. The apatite treatability test final report (PNNL-19572; Vermeul et al. 2010) documents the results of the first field-scale evaluation of the injectable apatite PRB technology. The apatite loading value in units of milligram-apatite per gram-sediment is incorrect in this and some other previous reports. The apatite loading in units of milligram phosphate per gram-sediment, however, is correct, and this is the unit used for comparison to field core sample measurements.

  8. Nutrient load analysis of Lago de Yojoa, Honduras

    E-Print Network [OSTI]

    Trate, Tia M. (Tia Marie)

    2006-01-01

    Lake Yojoa, Honduras is an important natural resource to the people of Honduras. The lake's water quality has been a controversial subject. This thesis describes a nutrient load analysis performed to gain a better understanding ...

  9. Minimized Space Conditioning Distribution Strategy for Low-load Homes

    Broader source: Energy.gov [DOE]

    This presentation was given at the Summer 2012 DOE Building America meeting on July 26, 2012, and addressed the question ŤWhat are the best HVAC solutions for low-load, high performance homes?"

  10. Load frequency control of interconnected power systems with system constraints 

    E-Print Network [OSTI]

    Choudhury, Md Ershadul H

    1993-01-01

    So far, researches in load frequency controls ( LFC) are involved in analysis of dynamic responses under normal conditions of the - interconnected power systems. In This research considers some system constraints (for example, one area fails...

  11. Analytical Methods for Implementing Industrial Load Management Programs 

    E-Print Network [OSTI]

    Hassig, N.; Chan, M.; Carlson, R.

    1982-01-01

    Many utilities have completed long-term planning studies and have shown that a load management program is cost effective. They are now actively implementing large-scale, system-wide programs such as demand subscription, interruptable rates, and time...

  12. Characterizing tensile loading responses of 3D printed samples

    E-Print Network [OSTI]

    Haid, Christopher M

    2014-01-01

    An experimental study was performed to characterize the loading response of samples manufactured through 3D printing. Tensile testing was performed on a number of 3D printed samples created through Fused Filament Fabrication ...

  13. Energy Storage for Use in Load Frequency Control

    E-Print Network [OSTI]

    Leitermann, Olivia

    Certain energy storage technologies are well-suited to the high-frequency, high-cycling operation which is required in provision of load frequency control (LFC). To limit the total stored energy capacity required while ...

  14. Uniformly Loaded Rectangular Thin Plates with Symmetrical Boundary Conditions

    E-Print Network [OSTI]

    Milan Batista

    2010-01-27

    In the article the Fourier series analytical solutions of uniformly loaded rectangular thin plates with symmetrical boundary conditions are considered. For all the cases the numerical values are tabulated.

  15. Improving shipboard applications of non-intrusive load monitoring

    E-Print Network [OSTI]

    Jones, Richard A. (Richard Alan), Nav. E. Massachusetts Institute of Technology

    2008-01-01

    The Non-Intrusive Load Monitor (NILM) measures equipment performance by measuring and analyzing the source power to the equipment at a single point in the electrical system. Previous studies have proven the usefulness of ...

  16. Assessing and Reducing Miscellaneous Electric Loads (MELs) in Banks

    SciTech Connect (OSTI)

    Rauch, Emily M.

    2012-09-01

    Miscellaneous electric loads (MELs) are loads outside of a building's core functions of heating, ventilating, air conditioning, lighting, and water heating. MELs are a large percentage of total building energy loads. This report reviews methods for reducing MELs in Banks. Reducing MELs in a bank setting requires both local and corporate action. Corporate action centers on activities to prioritize and allocate the right resources to correct procurement and central control issues. Local action includes branch assessment or audits to identify specific loads and needs. The worksheet at the end of this guide can help with cataloging needed information and estimating savings potential. The following steps provide a guide to MEL reductions in Bank Branches. The general process has been adapted from a process developed for office buildings the National Renewable Energy Laboratory (NREL, 2011).

  17. Geometric nonlinear analysis of microbeam under electrostatic loading 

    E-Print Network [OSTI]

    Murgude, Nikhil C.

    2001-01-01

    This study investigates the behavior of a microbeam subjected to electrostatic loading. Two devices, namely, a tungsten microtweezer and a clamped-clamped beam which is part of a micro-electromechanical system (MEMS), are used as the vehicles...

  18. Code of Practice Safety of Load on Vehicles 

    E-Print Network [OSTI]

    Anonymous

    1972-01-01

    The object of the Code is to provide operators, drivers and loading staff with guidance as to the basic safety principles that must be followed generally, and as to some particular precautions that can be taken to ensure ...

  19. Grid Integration of Aggregated Demand Response, Part I: Load Availability

    E-Print Network [OSTI]

    LBNL-6417E Grid Integration of Aggregated Demand Response, Part I: Load Availability Profiles Resources 4 #12;#12;#12;CHAPTER 3: Results: DR Profiles 3.1 Projected Demand Response Availability in 2020

  20. Active load management with advanced window wall systems: Research and industry perspectives

    E-Print Network [OSTI]

    2002-01-01

    Building Systems Active Load Management with Advanced WindowEconomy. Active Load Management with Advanced Window WallAC03-76SF00098. Active Load Management with Advanced Window