National Library of Energy BETA

Sample records for references primary poc

  1. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  2. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  3. Disability Employment POCs | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Disability Employment POCs Disability Employment POCs NAME ORGANIZATION PH # EMAL Donna Friend Headquarters Policy 202-586-5880 donna.friend@hq.doe.gov Rhonda Kennedy Headquarters Operations 202-586-3544 rhonda.kennedy@hq.doe.gov Tamara Lockhart-Rowley Bonneville Power Administration 530-230-5329 tlockhartrowley@bpa.gov Donna Wachter EE/Golden Field Office 720-356-1807 donna.wachter@go.doe.gov Michelle Litmer EMCBC 513-246-0514 michelle.litmer@emcbc.doe.gov Lisa Bonser EM/ Richland Operations

  4. SBOT OKLAHOMA SOUTHWESTERN POWER ADMIN POC Gary Bridges Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    OKLAHOMA SOUTHWESTERN POWER ADMIN POC Gary Bridges Telephone (918) 595-6671 Email gary.bridges@swpa...

  5. CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone

    Office of Environmental Management (EM)

    ADMINISTATIVE WASTE REMEDIATION CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen ... Security Systems Services (except Locksmiths) 561621 Hazardous Waste Treatment and ...

  6. Archive Reference Buildings by Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  7. MINING PENNSYLVANIA NATIONAL ENERGY TECHNOLOGY LAB - PA POC

    Energy Savers [EERE]

    MINING PENNSYLVANIA NATIONAL ENERGY TECHNOLOGY LAB - PA POC Larry Sullivan Telephone (412) 386-6115 Email larry.sullivan@netl.doe.gov Support Activities for Oil and Gas Operations 213112 WEST VIRGINIA NATIONAL ENERGY TECHNOLOGY LAB -WV POC Larry Sullivan Telephone (412) 386-6115 Email larry.sullivan@netl.doe.gov Support Activities for Oil and Gas Operations 213112 WYOMING ROCKY MOUNTAIN OILFIELD CENTER POC Jenny Krom Telephone (307) 233-4818 Email jenny.krom@rmotc.doe.gov Support Activities for

  8. UTILITIES COLORADO WESTERN POWER ADMIN POC Cheryl Drake Telephone

    Energy Savers [EERE]

    UTILITIES COLORADO WESTERN POWER ADMIN POC Cheryl Drake Telephone (720) 962-7154 Email drake@wapa.gov Electric Bulk Power Transmission and Control 221121 Electric Power Distribution 221122 GEORGIA SOUTHEASTERN POWER ADMIN POC Ann Craft Telephone (706) 213-3823 Email annc@sepa.doe.gov Electric Bulk Power Transmission and Control 221121 Electric Power Distribution 221122 OKLAHOMA SOUTHWESTERN POWER ADMIN POC Gary Bridges Telephone (918) 595-6671 Email gary.bridges@swpa.gov Electric Bulk Power

  9. EDUCATION CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone

    Energy Savers [EERE]

    EDUCATION CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone (510) 486-4506 Email dtchen@lbl.gov Computer Training 611420 Professional and Management Development Training 611430 LAWRENCE LIVERMORE LAB POC Jill Swanson Telephone (925) 423-4535 Email swanson6@llnl.gov Computer Training 611420 Professional and Management Development Training 611430 COLORADO GOLDEN FIELD OFFICE POC Karen Downs Telephone (720) 356-1269 Email karen.downs@go.doe.gov Computer Training 611420 Professional and

  10. CONSTRUCTION CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Oil and Gas Pipeline and Related Structures Construction 237120 All Other Specialty Trade Contractors 238990 NEVADA NEVADA SITE OFFICE POC Anita Ross Telephone (702) 295-5690 Email ...

  11. CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... All Other Professional, Scientific, and Technical Services 541990 NEVADA NEVADA SITE OFFICE POC Anita Ross Telephone (702) 295-5690 Email rossal@nv.doe.gov Other Accounting ...

  12. FORESTRY COLORADO WESTERN POWER ADMIN POC Cheryl Drake Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    FORESTRY COLORADO WESTERN POWER ADMIN POC Cheryl Drake Telephone (720) 962-7154 Email drake@wapa.gov Timber tract operations 113110 Cutting and transporting timber 113310 GEORGIA ...

  13. SBOT TEXAS PANTEX PLANT POC Brad Beck Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    PANTEX PLANT POC Brad Beck Telephone (806) 477-6192 Email bbrack@pantex.com ADMINISTATIVE WASTE REMEDIATION Facilities Support Services 561210 Executive Search Services 561312 ...

  14. SBOT SOUTH CAROLINA SAVANNAH RIVER LAB POC Sharon Campbell Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    SOUTH CAROLINA SAVANNAH RIVER LAB POC Sharon Campbell Telephone (800) 888-7986 Email sharon-pmmd.campbell@srs.gov EDUCATION Professional and Management Development Training 611430 ...

  15. COLORADO GOLDEN FIELD OFFICE POC Karen Downs Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Long-Distance 484230 WESTERN POWER ADMIN POC Cheryl Drake Telephone (720) 962-7154 Email drake@wapa.gov General Freight Trucking, Local 484110 General Freight Trucking, Long-Di...

  16. INFORMATION CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen

    Energy Savers [EERE]

    INFORMATION CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone (510) 486-4506 Email dtchen@lbl.gov Periodical Publishers 511120 Software Publishers 511210 Telecommunications Resellers 517911 Data Processing, Hosting, and Related Services 518210 Internet Publishing and Broadcasting and Web Search Portals 519130 LAWRENCE LIVERMORE LAB POC Jill Swanson Telephone (925) 423-4535 Email swanson6@llnl.gov Periodical Publishers 511120 Software Publishers 511210 Telecommunications Resellers 517911

  17. PUBLIC ADMINISTRATION COLORADO GOLDEN FIELD OFFICE POC Karen Downs

    Energy Savers [EERE]

    PUBLIC ADMINISTRATION COLORADO GOLDEN FIELD OFFICE POC Karen Downs Telephone (720) 356-1269 Email karen.downs@go.doe.gov Police Protection 922120 Administration of Education Programs 923110 International Affairs 928120 DIST OF COLUMBIA HEADQUARTERS PROCUREMENT POC Michael Raizen Telephone (202) 287-1512 Email michael.raizen@hq.doe.gov Police Protection 922120 Administration of Education Programs 923110 Administration of Human Resource Programs (except Education, Public Health, and Veterans'

  18. MANUFACTURING CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen

    Energy Savers [EERE]

    MANUFACTURING CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone (510) 486-4506 Email dtchen@lbl.gov Industrial Gas Manufacturing 325120 All Other Basic Inorganic Chemical Manufacturing 325188 Plastics Material and Resin Manufacturing 325211 Explosives Manufacturing 325920 All Other Plastics Product Manufacturing 326199 Nonferrous Metal (except Copper and Aluminum) Rolling, Drawing, and Extruding 331491 Fabricated Structural Metal Manufacturing 332312 Metal Tank (Heavy Gauge)

  19. CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone

    Energy Savers [EERE]

    PROFESSIONAL / SCIENTIFIC / TECHNICAL CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone (510) 486-4506 Email dtchen@lbl.gov Engineering Services 541330 Drafting Services 541340 Geophysical Surveying and Mapping Services 541360 Testing Laboratories 541380 Custom Computer Programming Services 541511 Computer Systems Design Services 541512 Other Computer Related Services 541519 Administrative Management and General Management Consulting Services 541611 Other Scientific and Technical

  20. Detailed Chemical Kinetic Reaction Mechanisms for Primary Reference Fuels for Diesel Cetane Number and Spark-Ignition Octane Number

    SciTech Connect (OSTI)

    Westbrook, C K; Pitz, W J; Mehl, M; Curran, H J

    2010-03-03

    For the first time, a detailed chemical kinetic reaction mechanism is developed for primary reference fuel mixtures of n-hexadecane and 2,2,4,4,6,8,8-heptamethyl nonane for diesel cetane ratings. The mechanisms are constructed using existing rules for reaction pathways and rate expressions developed previously for the primary reference fuels for gasoline octane ratings, n-heptane and iso-octane. These reaction mechanisms are validated by comparisons between computed and experimental results for shock tube ignition and for oxidation under jet-stirred reactor conditions. The combined kinetic reaction mechanism contains the submechanisms for the primary reference fuels for diesel cetane ratings and submechanisms for the primary reference fuels for gasoline octane ratings, all in one integrated large kinetic reaction mechanism. Representative applications of this mechanism to two test problems are presented, one describing fuel/air autoignition variations with changes in fuel cetane numbers, and the other describing fuel combustion in a jet-stirred reactor environment with the fuel varying from pure 2,2,4,4,6,8,8-heptamethyl nonane (Cetane number of 15) to pure n-hexadecane (Cetane number of 100). The final reaction mechanism for the primary reference fuels for diesel fuel and gasoline is available on the web.

  1. Points of Contact (POCs) | U.S. DOE Office of Science (SC)

    Office of Science (SC) Website

    Points of Contact (POCs) Print Text Size: A A A FeedbackShare Page Useful Websites and Email Addresses CRM Prices and Certificates CRM Ordering Information General Questions ...

  2. POC-SCALE TESTING OF A DRY TRIBOELECTROSTATIC SEPARATOR FOR FINE COAL CLEANING

    SciTech Connect (OSTI)

    A.D. Walters; G.H. Luttrell; G.T. Adel; R.-H. Yoon

    1999-01-01

    It is the objective of the current project to further refine the TES process developed at FETC through bench-scale and proof-of-concept (POC) test programs. The bench-scale test program is aimed at studying the charging mechanisms associated with coal and mineral matter and improving the triboelectrification process, while the POC test program is aimed at obtaining scale-up information. The POC tests will be conducted at a throughput of 200-250 kg/hr. It is also the objective of the project to conduct a cost analysis based on the scale-up information obtained in the present work. Specific objectives of the work conducted during the current reporting period can be summarized as follows: to complete the engineering design of the TES tribocharging system and electrostatic separator, and to continue work related to the procurement and fabrication of the key components required to construct and install the proposed POC test circuit.

  3. POCs for Emergency Requests of Oil from the SPR | Department of Energy

    Energy Savers [EERE]

    POCs for Emergency Requests of Oil from the SPR POCs for Emergency Requests of Oil from the SPR SPR personnel are available to answer any questions you might have. Please contact them immediately in the event of an emergency which might lead you to request SPR assistance. PDF icon Points of Contact for Emergency Supply Requests More Documents & Publications Small Business Program Manager Directory SPR Pro Forma Contract PIA - WEB Physical Security Major Application

  4. POC-SCALE TESTING OF A DRY TRIBOELECTROSTATIC SEPARATOR FOR FINE COAL CLEANING

    SciTech Connect (OSTI)

    R.-H. Yoon; G.H. Luttrell; G.T. Adel; A.D. Walters

    1999-04-01

    The project has reached the point where the Proof of Concept (POC) electrostatic separator is in the design stage. During the quarter, the design concepts of the TES unit have been finalized with Carpco. During the past quarter, most of the personnel assigned to this project have been performing work elements associated with process/engineering design (Task 3) of the process including the TES unit, the Turbo charger and the product conveying system.

  5. POC-SCALE TESTING OF A DRY TRIBOELECTROSTATIC SEPARATOR FOR FINE COAL CLEANING

    SciTech Connect (OSTI)

    R.H. Yoon; G.H. Luttrell; E.S. Yan; A.D. Walters

    2001-04-30

    Numerous advanced coal cleaning processes have been developed in recent years that are capable of substantially reducing both ash- and sulfur-forming minerals from coal. However, most of the processes involve fine grinding and use water as the cleaning medium; therefore, the clean coal products must be dewatered before they can be transported and burned. Unfortunately, dewatering fine coal is costly, which makes it difficult to deploy advanced coal cleaning processes for commercial applications. As a means of avoiding problems associated with the fine coal dewatering, the National Energy Technology Laboratory (NETL) developed a dry coal cleaning process in which mineral matter is separated from coal without using water. In this process, pulverized coal is subjected to triboelectrification before being placed in an electric field for electrostatic separation. The triboelectrification is accomplished by passing a pulverized coal through an in-line mixer made of copper. Copper has a work function that lies between that of carbonaceous material (coal) and mineral matter. Thus, coal particles impinging on the copper wall lose electrons to the metal thereby acquiring positive charges, while mineral matter impinging on the wall gain electrons to acquire negative charges. The charged particles then pass through an electric field where they are separated according to their charges into two or more products depending on the configuration of the separator. The results obtained at NETL showed that it is capable of removing more than 90% of the pyritic sulfur and 70% of the ash-forming minerals from a number of eastern U.S. coals. However, the BTU recoveries were less than desirable. The laboratory-scale batch triboelectrostatic separator (TES) used by NETL relied on adhering charged particles on parallel electrode surfaces and scraping them off. Therefore, its throughput will be proportional to the electrode surface area. If this laboratory device is scaled-up as is, it would suffer from low throughput capacities and high maintenance requirements. In general, surface area-based separators (e.g., shaking tables, magnetic drum separator, electrodynamic separator, etc.) have lower throughput capacities than volume-based separators (e.g., flotation cell, dense-medium bath, cyclones, etc.) by an order of magnitude. Furthermore, the electrodes of the laboratory unit need to be cleaned frequently, creating a high maintenance requirement if it is scaled-up to a commercial unit. The bench-scale continuous TES unit developed at NETL, on the other hand, separates positively and negatively charged particles by splitting the gaseous stream containing these particles in an electric field by means of a flow splitter, so that the oppositely charged particles can be directed into different compartments. This device is fundamentally different from the laboratory unit in that the former is a surface area-based separator, while the latter is a volume-based separator. The bench-scale unit is referred to as an entrained flow separator by the in-house researchers at NETL. Thus, the entrained flow TES unit is a significant improvement over the laboratory unit with regard to throughput capacity. In the present work, the entrained flow separator concept will be utilized for developing a proof-of concept (POC) separator that can be scaled-up to commercial size units. To accomplish this, it is necessary to develop a bench-scale separator that can achieve high Btu recoveries while maintaining the high degree of separation efficiencies. It is the objective of the present investigation to develop an efficient separator by studying the mechanisms of triboelectrification and investigating better ways of separating the charged particles. An important criterion for developing efficient separators is that they not only provide high separation efficiencies but also have high throughput capacities, which are essential ingredients for successful commercialization.

  6. POC-scale testing of a dry triboelectrostatic separator for fine coal cleaning

    SciTech Connect (OSTI)

    R.-H. Yoon; G.H. Luttrell; A.D. Walters

    1999-10-01

    During the past quarter, the installation, testing and shakedown phases of commissioning the TES unit were completed (Tasks 4, 5.1 and 5.2). A representative from Carpco Inc. was on site to provide training in the operation of the test unit and assist with the initial test runs. Problems have been encountered with the recycle conveyor generating dust that neutralizes the particle charge. Testing has continued by batch feeding the unit while the recycle conveying problem is being solved. Good separations have been achieved while operating in this mode. Comparison tests have also been carried out using a bench-scale triboelectrostatic separator in parallel with the POC Carpco unit.

  7. POC-scale testing of a dry triboelectrostatic separator for fine coal cleaning

    SciTech Connect (OSTI)

    R.-H. Yoon; G.H. Luttrell; G.T. Adel; A.D. Walters

    1999-07-01

    The Proof-of-Concept (POC) triboelectrostatic separator (TES) has now been successfully installed at the Virginia Tech pilot-plant. As a result, most of the personnel assigned to this project during the past quarter have been performing work elements associated with the installation and shakedown testing of the electrostatic separator, tribocharger system, product conveying systems and nitrogen purge system (Tasks 4, 5.1 and 5.2). A representative from Carpco also carried out training in the operating features of the unit during the past month. Most of the shakedown test work has now been successfully completed. However, several minor operational problems associated with the pilot-scale equipment are currently in the process of being resolved.

  8. Appendix A: Reference case projections

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    Reference case projections Table A1. World total primary energy consumption by region, Reference case, 2011-40 (quadrillion Btu) Region History Projections Average annual percent ...

  9. POC-SCALE TESTING OF OIL AGGLOMERATION TECHNIQUES AND EQUIPMENT FOR FINE COAL PROCESSING

    SciTech Connect (OSTI)

    1998-01-01

    This report covers the technical progress achieved from October 1, 1997 to December 31, 1997 on the POC-Scale Testing of Oil Agglomeration Techniques and Equipment for Fine Coal Processing project. Experimental test procedures and the results related to the processing of coal fines originating from process streams generated at the Shoal Creek Mine preparation plant, owned and operated by the Drummond Company Inc. of Alabama, are described. Two samples of coal fines, namely Cyclone Overflow and Pond Fines were investigated. The batch test results showed that by applying the Aglofloat technology a significant ash removal might be achieved at a very high combustible matter recovery: · for the Cyclone Overflow sample the ash reduction was in the range 50 to 55% at combustible matter recovery about 98% · for the Pond Fines sample the ash reduction was up to 48% at combustible matter recovery up to 85%. Additional tests were carried out with the Alberta origin Luscar Mine coal, which will be used for the parametric studies of agglomeration equipment at the 250 kg/h pilot plant. The Luscar coal is very similar to the Mary Lee Coal Group (processed at Shoal Creek Mine preparation plant) in terms of rank and chemical composition.

  10. POC-SCALE TESTING OF A DRY TRIBOELECTROSTATIC SEPARATOR FOR FINE COAL CLEANING

    SciTech Connect (OSTI)

    R.-H. Yoon; G.H. Luttrell; B. Luvsansambuu; A.D. Walters

    2000-10-01

    Work continued during the past quarter to improve the performance of the POC-scale unit. For the charging system, a more robust ''turbocharger'' has been fabricated and installed. All of the internal components of the charger have been constructed from the same material (i.e., Plexiglas) to prevent particles from contacting surfaces with different work functions. For the electrode system, a new set of vinyl-coated electrodes have been constructed and tested. The coated electrodes (i) allow higher field strengths to be tested without of risk of arcing and (ii) minimize the likelihood of charge reversal caused by particles colliding with the conducting surfaces of the uncoated electrodes. Tests are underway to evaluate these modifications. Several different coal samples were collected for testing during this reporting period. These samples included (i) a ''reject'' material that was collected from the pyrite trap of a pulverizer at a coal-fired power plant, (ii) an ''intermediate'' product that was selectively withdrawn from the grinding chamber of a pulverizer at a power plant, and (iii) a run-of-mine feed coal from an operating coal preparation plant. Tests were conducted with these samples to investigate the effects of several key parameters (e.g., particle size, charger type, sample history, electrode coatings, etc.) on the performance of the bench-scale separator.

  11. POC-SCALE TESTING OF A DRY TRIBOELECTROSTATIC SEPARATOR FOR FINE COAL CLEANING

    SciTech Connect (OSTI)

    R.-H. Yoon; G.H. Luttrell; A.D. Walters

    2000-01-01

    During the past quarter, several modifications were made to the TES unit and the materials handling system. The cylindrical electrodes were replaced by a set of screen electrodes to provide a more uniform electrostatic field. The problem with the recycle conveyor neutralizing the particle charge was also corrected by replacing it with a bucket elevator. In addition, problems with the turbocharger were corrected by increasing the number of charging stages from one to two. These modifications have significantly improved the separation performance and have permitted the POC-scale unit to achieve results in line with those obtained by the bench-scale separator. The testing phase of the project was continued at a rapid pace during this quarter. The test work showed that the modifications to the TES unit and the reduction in feed size from 28 mesh to 35 mesh resulted in significant overall improvement in yield and combustible recovery compared to the data reported in the last quarter. At that time, there was a significant discrepancy between the bench-scale and the pilot-scale results. The pilot-scale test work is now approaching the bench scale test results. However, further pilot-scale test work is required to further improve the results and duplicate the bench-scale test work.

  12. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Materials Reference Materials Large Scale Computing and Storage Requirements for Biological and Environmental Research May 7-8, 2009 Invitation Workshop Invitation Letter...

  13. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Materials Reference Materials Large Scale Computing and Storage Requirements for Basic Energy Sciences February 9-10, 2010 Official DOE Invitation Workshop Invitation...

  14. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Materials Reference Materials Large Scale Computing and Storage Requirements for Basic Energy Sciences February 9-10, 2010 Official DOE Invitation Workshop Invitation Letter from DOE Associate Directors Last edited: 2016-04-29 11:35:05

  15. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Materials Reference Materials Large Scale Computing and Storage Requirements for Advanced Scientific Computing Research January 5-6, 2011 Official DOE Invitation Workshop Invitation Letter from DOE Associate Directors NERSC Documents NERSC science requirements home page NERSC science requirements workshop page NERSC science requirements case study FAQ Previous NERSC Requirements Workshops Biological and Environmental Research (BER) Basic Energy Sciences (BES) Fusion Energy Sciences

  16. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Materials Reference Materials Large Scale Computing and Storage Requirements for Biological and Environmental Research May 7-8, 2009 Invitation Workshop Invitation Letter from DOE Associate Directors Workshop Invitation Letter from DOE ASCR Program Manager Yukiko Sekine Last edited: 2016-04-29 11:34:54

  17. Reference Buildings by Building Type: Primary school

    Broader source: Energy.gov [DOE]

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  18. Quick Reference

    Broader source: Energy.gov (indexed) [DOE]

    Reference 2015 Annual Planning Summary (APS) User's Guide 1, 2 PART 1 OFFICE Enter the office preparing this APS. NEPA REVIEWS Select one of two responses. SITE-WIDE EISs Select...

  19. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Materials Reference Materials Large Scale Computing and Storage Requirements for Fusion Energy Sciences August 3-4, 2010 Official DOE Invitation Workshop Invitation Letter from DOE Associate Directors [not available] NERSC Documents NERSC science requirements home page NERSC science requirements workshop page NERSC science requirements case study FAQ Workshop Agenda Previous NERSC Requirements Workshops Biological and Environmental Research (BER) Basic Energy Sciences (BES) Fusion

  20. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Materials Reference Materials Large Scale Computing and Storage Requirements for High Energy Physics November 12-13, 2009 Official DOE Invitation Workshop Invitation Letter from DOE Associate Directors NERSC Documents NERSC science requirements home page NERSC science requirements workshop page NERSC science requirements case study FAQ Workshop Agenda Previous NERSC Requirements Workshops Biological and Environmental Research (BER) Basic Energy Sciences (BES) Fusion Energy Sciences

  1. Reference Material

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Materials There are a variety of reference materials the NSSAB utilizes and have been made available on its website. Documents Fact Sheets - links to Department of Energy Nevada Field Office webpage Public Reading Room NTA Public Reading Facility Open Monday through Friday, 7:30 am to 4:30 pm (except holidays) 755C East Flamingo Road Las Vegas, Nevada 89119 Phone (702) 794-5106 http://www.nv.doe.gov/library/testingarchive.aspx DOE Electronic Database Also available to the public is an

  2. Poroelastic references

    SciTech Connect (OSTI)

    Christina Morency

    2014-12-12

    This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

  3. Poroelastic references

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Christina Morency

    This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

  4. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ID 412- 11/16/2012 - Page 1 Log No 2012-263 Reference Materials * Transporting Radioactive Waste to the Nevada National Security Site fact sheet (ww.nv.energy.gov/library/factsheets/DOENV_990.pdf) - Generators contract with commercial carriers - U.S. Department of Transportation regulations require carriers to select routes which minimize radiological risk * Drivers Route and Shipment Information Questionnaire completed by drivers to document routes taken to the NNSS upon entry into Nevada -

  5. Quick Reference

    Energy Savers [EERE]

    Quick Reference 2016 Annual Planning Summary (APS) User's Guide 1, 2 PART 1 OFFICE Enter the office preparing this APS. NEPA REVIEWS Select one of two responses. SITE-WIDE Select one of three responses. DOCUMENT NUMBER & TITLE Enter the DOE NEPA identification number if available, e.g., DOE/EIS-XXXX. If no document number has been assigned, enter N/A. Also enter the document title. Text is limited to 350 characters. PART 2 TYPE Select the type of document using the dropdown menu. STATUS

  6. Texas Large Construction Site Notice for Primary Operators |...

    Open Energy Info (EERE)

    navigation, search OpenEI Reference LibraryAdd to library Reference: Texas Large Construction Site Notice for Primary Operators Published Texas Commission on Environmental...

  7. POC-scale testing of an advanced fine coal dewatering equipment/technique. Quarterly technical progress report No. 5, October--December, 1995

    SciTech Connect (OSTI)

    Groppo, J.G.; Parekh, B.K.

    1996-02-01

    Froth flotation technique is an effective and efficient process for recovering of ultra-fine (minus 74{mu}m) clean coal. Economical dewatering of an ultrafine clean coal product to a 20% level moisture will be an important step in successful implementation of the advanced cleaning processes. The main objective of the proposed program is to evaluate a novel surface modification technique, which utilizes the synergistic effect of metal ions-surfactant combination, for dewatering of ultra-fine clean coal on a proof-of-concept scale of 1 to 2 tph. The novel surface modification technique developed at the the University of Kentucky Center for Applied Energy Research will be evaluated using vacuum, centrifuge, and hyperbaric filtration equipment. Dewatering tests will be conducted using the fine clean coal froth produced by the column flotation units at the Powell Mountain Coal Company, Mayflower Preparation Plant in St. Charles, Virginia. The POC-scale studies will be conducted on two different types of clean coal, namely, high sulfur and low sulfur clean coal. Accomplishments for the past quarter are described.

  8. NREL: Measurements and Characterization - Reference Cell Calibration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Cell Calibration The National Renewable Energy Laboratory (NREL) calibrates primary reference cells for in-house use and for use by other national laboratories. We also do so to provide our clients and partners with a path for traceability to standards. Our laboratory is one of only four facilities in the world certified to calibrate reference cells in accordance with the world photovoltaic scale, and these measurements are accredited to International Organization for Standardization

  9. 20110928_RFLMA_POCs.pdf

    Office of Legacy Management (LM)

  10. Appendix A: Reference case projections

    U.S. Energy Information Administration (EIA) Indexed Site

    U.S. Energy Information Administration | International Energy Outlook 2016 Reference case projections Table A1. World total primary energy consumption by region, Reference case, 2011-40 (quadrillion Btu) Region History Projections Average annual percent change, 2012-40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas 120.6 118.1 125.7 128.1 130.7 133.8 138.1 0.6 United States a 96.8 94.4 100.8 102.0 102.9 103.8 105.7 0.4 Canada 14.5 14.5 15.1 15.6 16.3 17.1 18.1 0.8 Mexico and Chile 9.3

  11. High frequency reference electrode

    DOE Patents [OSTI]

    Kronberg, James W.

    1994-01-01

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or "halo" at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes.

  12. High frequency reference electrode

    DOE Patents [OSTI]

    Kronberg, J.W.

    1994-05-31

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes. 4 figs.

  13. Optical voltage reference

    DOE Patents [OSTI]

    Rankin, R.; Kotter, D.

    1994-04-26

    An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

  14. Optical voltage reference

    DOE Patents [OSTI]

    Rankin, Richard; Kotter, Dale

    1994-01-01

    An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.

  15. Appendix A: Reference case

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    4 Reference case Table A2. Energy consumption by sector and source (quadrillion Btu per year, unless otherwise noted) Energy Information Administration Annual Energy Outlook 2014...

  16. Appendix A: Reference case

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    Reference case Energy Information Administration Annual Energy Outlook 2014 Table A17. Renewable energy consumption by sector and source (quadrillion Btu) Sector and source...

  17. Reference Documents | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    Reference Documents Summary References Main Draft SEIS References Additional SEIS References Appendix C References Appendix D References Appendix E References Appendix F References Learn More Summary References Main Draft SEIS References Appendix C References Appendix D References Appendix E References Appendix F References Additional SEIS references

  18. Sandia Energy - Reference Model Documents

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Documents Home Stationary Power Energy Conversion Efficiency Water Power Reference Model Project (RMP) Reference Model Documents Reference Model DocumentsTara Camacho-Lopez2015-05-...

  19. Multifunctional reference electrode (Patent) | DOEPatents

    Office of Scientific and Technical Information (OSTI)

    Multifunctional reference electrode Title: Multifunctional reference electrode A multifunctional, low mass reference electrode of a nickel tube, thermocouple means inside the ...

  20. reference | OpenEI Community

    Open Energy Info (EERE)

    reference Home Jweers's picture Submitted by Jweers(88) Contributor 7 August, 2013 - 18:23 New Robust References citation citing developer formatting reference Semantic Mediawiki...

  1. Value of Information References

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Morency, Christina

    This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

  2. Value of Information References

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Morency, Christina

    2014-12-12

    This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

  3. Precision displacement reference system

    DOE Patents [OSTI]

    Bieg, Lothar F.; Dubois, Robert R.; Strother, Jerry D.

    2000-02-22

    A precision displacement reference system is described, which enables real time accountability over the applied displacement feedback system to precision machine tools, positioning mechanisms, motion devices, and related operations. As independent measurements of tool location is taken by a displacement feedback system, a rotating reference disk compares feedback counts with performed motion. These measurements are compared to characterize and analyze real time mechanical and control performance during operation.

  4. Membrane reference electrode

    DOE Patents [OSTI]

    Redey, Laszlo; Bloom, Ira D.

    1989-01-01

    A reference electrode utilizes a small thin, flat membrane of a highly conductive glass placed on a small diameter insulator tube having a reference material inside in contact with an internal voltage lead. When the sensor is placed in a non-aqueous ionic electrolytic solution, the concentration difference across the glass membrane generates a low voltage signal in precise relationship to the concentration of the species to be measured with high spatial resolution.

  5. Membrane reference electrode

    DOE Patents [OSTI]

    Redey, L.; Bloom, I.D.

    1988-01-21

    A reference electrode utilizes a small thin, flat membrane of a highly conductive glass placed on a small diameter insulator tube having a reference material inside in contact with an internal voltage lead. When the sensor is placed in a non-aqueous ionic electrolytic solution, the concentration difference across the glass membrane generates a low voltage signal in precise relationship to the concentration of the species to be measured, with high spatial resolution. 2 figs.

  6. Policies, Manuals & References

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    03-00203-0311.tif-277x300 Key Berkeley Lab Policy Documents Regulations & Procedures Manual (RPM) : The RPM is the primary policy document for Berkeley Lab and links out to many...

  7. The NEPA reference guide

    SciTech Connect (OSTI)

    Swartz, L.L.; Reinke, D.C.

    1999-10-01

    The NEPA Reference Guide conveniently organizes and indexes National Environmental Policy Act (NEPA) and Council on Environmental Quality (CEQ) regulations and guidance, along with relevant federal case law, all in one place. It allows the user to quickly learn the statutory, regulatory, and case law authority for a large number of NEPA subjects. A unique feature of The NEPA Reference Guide is its detailed index that includes a large number of diverse NEPA subjects. The index enables users to find and compile any statutory, regulatory (including CEQ guidance), and case law original source material and references on virtually any NEPA subject. This will be an especially useful tool for new NEPA practitioners who need to become immersed in a particular subject quickly.

  8. Multifunctional reference electrode

    DOE Patents [OSTI]

    Redey, Laszlo; Vissers, Donald R.

    1983-01-01

    A multifunctional, low mass reference electrode of a nickel tube, thermocouple means inside the nickel tube electrically insulated therefrom for measuring the temperature thereof, a housing surrounding the nickel tube, an electrolyte having a fixed sulfide ion activity between the housing and the outer surface of the nickel tube forming the nickel/nickel sulfide/sulfide half-cell. An ion diffusion barrier is associated with the housing in contact with the electrolyte. Also disclosed is a cell using the reference electrode to measure characteristics of a working electrode.

  9. Multifunctional reference electrode

    DOE Patents [OSTI]

    Redey, L.; Vissers, D.R.

    1981-12-30

    A multifunctional, low mass reference electrode of a nickel tube, thermocouple means inside the nickel tube electrically insulated therefrom for measuring the temperature thereof, a housing surrounding the nickel tube, an electrolyte having a fixed sulfide ion activity between the housing and the outer surface of the nickel tube forming the nickel/nickel sulfide/sulfide half-cell are described. An ion diffusion barrier is associated with the housing in contact with the electrolyte. Also disclosed is a cell using the reference electrode to measure characteristics of a working electrode.

  10. Aluminum reference electrode

    DOE Patents [OSTI]

    Sadoway, D.R.

    1988-08-16

    A stable reference electrode is described for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na[sub 3]AlF[sub 6], wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution. 1 fig.

  11. Aluminum reference electrode

    DOE Patents [OSTI]

    Sadoway, Donald R. (Belmont, MA)

    1988-01-01

    A stable reference electrode for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na.sub.3 AlF.sub.6, wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution.

  12. TriBITS Developers Guide and Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    TriBITS Developers Guide and Reference Ross Bartlett Oak Ridge National Laboratory March 31, 2014 CASL-U-2014-0075-000-E CASL-U-2014-0075-000-b TriBITS Developers Guide and Reference Author: Roscoe A. Bartlett (bartlettra@ornl.gov) Abstract This document describes the usage of TriBITS to build, test, and deploy complex software. The primary audience are those individuals who develop on a software project which uses TriBITS. The overall structure of a TriBITS project is described including all of

  13. Reference Model Development

    SciTech Connect (OSTI)

    Jepsen, Richard

    2011-11-02

    Presentation from the 2011 Water Peer Review in which principal investigator discusses project progress to develop a representative set of Reference Models (RM) for the MHK industry to develop baseline cost of energy (COE) and evaluate key cost component/system reduction pathways.

  14. OSH technical reference manual

    SciTech Connect (OSTI)

    Not Available

    1993-11-01

    In an evaluation of the Department of Energy (DOE) Occupational Safety and Health programs for government-owned contractor-operated (GOCO) activities, the Department of Labor`s Occupational Safety and Health Administration (OSHA) recommended a technical information exchange program. The intent was to share written safety and health programs, plans, training manuals, and materials within the entire DOE community. The OSH Technical Reference (OTR) helps support the secretary`s response to the OSHA finding by providing a one-stop resource and referral for technical information that relates to safe operations and practice. It also serves as a technical information exchange tool to reference DOE-wide materials pertinent to specific safety topics and, with some modification, as a training aid. The OTR bridges the gap between general safety documents and very specific requirements documents. It is tailored to the DOE community and incorporates DOE field experience.

  15. EFRC Management Reference Document

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    EFRC management reference document Energy Frontier Research Centers Acknowledgments of Support (v.1, October 2009) Office of Basic Energy Sciences Office of Science US Department of Energy How to Acknowledge Basic Energy Sciences-Energy Frontier Research Center (BES-EFRC) funding in papers, presentations, and other materials: For a publication on work supported wholly under your EFRC, the acknowledgement should at a minimum state that "This material is based upon work supported as part of

  16. Alignment reference device

    DOE Patents [OSTI]

    Patton, Gail Y.; Torgerson, Darrel D.

    1987-01-01

    An alignment reference device provides a collimated laser beam that minimizes angular deviations therein. A laser beam source outputs the beam into a single mode optical fiber. The output end of the optical fiber acts as a source of radiant energy and is positioned at the focal point of a lens system where the focal point is positioned within the lens. The output beam reflects off a mirror back to the lens that produces a collimated beam.

  17. Reference Model Project (RMP)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Model Project (RMP) - Sandia Energy Energy Search Icon Sandia Home Locations Contact Us Employee Locator Energy & Climate Secure & Sustainable Energy Future Stationary Power Energy Conversion Efficiency Solar Energy Wind Energy Water Power Supercritical CO2 Geothermal Natural Gas Safety, Security & Resilience of the Energy Infrastructure Energy Storage Nuclear Power & Engineering Grid Modernization Battery Testing Nuclear Fuel Cycle Defense Waste Management Programs

  18. Coal Data: A reference

    SciTech Connect (OSTI)

    Not Available

    1991-11-26

    The purpose of Coal Data: A Reference is to provide basic information on the mining and use of coal, an important source of energy in the United States. The report is written for a general audience. The goal is to cover basic material and strike a reasonable compromise between overly generalized statements and detailed analyses. The section ``Coal Terminology and Related Information`` provides additional information about terms mentioned in the text and introduces new terms. Topics covered are US coal deposits, resources and reserves, mining, production, employment and productivity, health and safety, preparation, transportation, supply and stocks, use, coal, the environment, and more. (VC)

  19. STEP Intern Reference Check Sheet

    Broader source: Energy.gov [DOE]

    STEP Intern Reference Check Sheet, from the Tool Kit Framework: Small Town University Energy Program (STEP).

  20. Coal data: A reference

    SciTech Connect (OSTI)

    Not Available

    1995-02-01

    This report, Coal Data: A Reference, summarizes basic information on the mining and use of coal, an important source of energy in the US. This report is written for a general audience. The goal is to cover basic material and strike a reasonable compromise between overly generalized statements and detailed analyses. The section ``Supplemental Figures and Tables`` contains statistics, graphs, maps, and other illustrations that show trends, patterns, geographic locations, and similar coal-related information. The section ``Coal Terminology and Related Information`` provides additional information about terms mentioned in the text and introduces some new terms. The last edition of Coal Data: A Reference was published in 1991. The present edition contains updated data as well as expanded reviews and additional information. Added to the text are discussions of coal quality, coal prices, unions, and strikes. The appendix has been expanded to provide statistics on a variety of additional topics, such as: trends in coal production and royalties from Federal and Indian coal leases, hours worked and earnings for coal mine employment, railroad coal shipments and revenues, waterborne coal traffic, coal export loading terminals, utility coal combustion byproducts, and trace elements in coal. The information in this report has been gleaned mainly from the sources in the bibliography. The reader interested in going beyond the scope of this report should consult these sources. The statistics are largely from reports published by the Energy Information Administration.

  1. Long life reference electrode

    DOE Patents [OSTI]

    Yonco, R.M.; Nagy, Z.

    1989-04-04

    An external, reference electrode is provided for long term use with a high temperature, high pressure system. The electrode is arranged in a vertical, electrically insulative tube with an upper portion serving as an electrolyte reservoir and a lower portion in electrolytic communication with the system to be monitored. The lower end portion includes a flow restriction such as a porous plug to limit the electrolyte release into the system. A piston equalized to the system pressure is fitted into the upper portion of the tube to impart a small incremental pressure to the electrolyte. The piston is selected of suitable size and weight to cause only a slight flow of electrolyte through the porous plug into the high pressure system. This prevents contamination of the electrolyte but is of such small flow rate that operating intervals of a month or more can be achieved. 2 figs.

  2. Long life reference electrode

    DOE Patents [OSTI]

    Yonco, Robert M.; Nagy, Zoltan

    1989-01-01

    An external, reference electrode is provided for long term use with a high temperature, high pressure system. The electrode is arranged in a vertical, electrically insulative tube with an upper portion serving as an electrolyte reservior and a lower portion in electrolytic communication with the system to be monitored. The lower end portion includes a flow restriction such as a porous plug to limit the electrolyte release into the system. A piston equalized to the system pressure is fitted into the upper portion of the tube to impart a small incremental pressure to the electrolyte. The piston is selected of suitable size and weight to cause only a slight flow of electrolyte through the porous plug into the high pressure system. This prevents contamination of the electrolyte but is of such small flow rate that operating intervals of a month or more can be achieved.

  3. Long life reference electrode

    DOE Patents [OSTI]

    Yonco, R.M.; Nagy, Z.

    1987-07-30

    An external, reference electrode is provided for long term use with a high temperature, high pressure system. The electrode is arranged in a vertical, electrically insulative tube with an upper portion serving as an electrolyte reservoir and a lower portion in electrolytic communication with the system to be monitored. The lower end portion includes a flow restriction such as a porous plug to limit the electrolyte release into the system. A piston equalized to the system pressure is fitted into the upper portion of the tube to impart a small incremental pressure to the electrolyte. The piston is selected of suitable size and weight to cause only a slight flow of electrolyte through the porous plug into the high pressure system. This prevents contamination of the electrolyte but is of such small flow rate that operating intervals of a month or more can be achieved. 2 figs.

  4. Sensor Characteristics Reference Guide

    SciTech Connect (OSTI)

    Cree, Johnathan V.; Dansu, A.; Fuhr, P.; Lanzisera, Steven M.; McIntyre, T.; Muehleisen, Ralph T.; Starke, M.; Banerjee, Pranab; Kuruganti, T.; Castello, C.

    2013-04-01

    The Buildings Technologies Office (BTO), within the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), is initiating a new program in Sensor and Controls. The vision of this program is: • Buildings operating automatically and continuously at peak energy efficiency over their lifetimes and interoperating effectively with the electric power grid. • Buildings that are self-configuring, self-commissioning, self-learning, self-diagnosing, self-healing, and self-transacting to enable continuous peak performance. • Lower overall building operating costs and higher asset valuation. The overarching goal is to capture 30% energy savings by enhanced management of energy consuming assets and systems through development of cost-effective sensors and controls. One step in achieving this vision is the publication of this Sensor Characteristics Reference Guide. The purpose of the guide is to inform building owners and operators of the current status, capabilities, and limitations of sensor technologies. It is hoped that this guide will aid in the design and procurement process and result in successful implementation of building sensor and control systems. DOE will also use this guide to identify research priorities, develop future specifications for potential market adoption, and provide market clarity through unbiased information

  5. Attachment F- Bibliography and References

    Broader source: Energy.gov [DOE]

    These documents are listed in Attachment F - Bibliography and References section of the Phase 2 Radiological Release Accident Investigation Report.

  6. Capillary reference half-cell

    DOE Patents [OSTI]

    Hall, Stephen H.

    1996-01-01

    The present invention is a reference half-cell electrode wherein intermingling of test fluid with reference fluid does not affect the performance of the reference half-cell over a long time. This intermingling reference half-cell may be used as a single or double junction submersible or surface reference electrode. The intermingling reference half-cell relies on a capillary tube having a first end open to reference fluid and a second end open to test fluid wherein the small diameter of the capillary tube limits free motion of fluid within the capillary to diffusion. The electrode is placed near the first end of the capillary in contact with the reference fluid. The method of operation of the present invention begins with filling the capillary tube with a reference solution. After closing the first end of the capillary, the capillary tube may be fully submerged or partially submerged with the second open end inserted into test fluid. Since the electrode is placed near the first end of the capillary, and since the test fluid may intermingle with the reference fluid through the second open end only by diffusion, this intermingling capillary reference half-cell provides a stable voltage potential for long time periods.

  7. Capillary reference half-cell

    DOE Patents [OSTI]

    Hall, S.H.

    1996-02-13

    The present invention is a reference half-cell electrode wherein intermingling of test fluid with reference fluid does not affect the performance of the reference half-cell over a long time. This intermingling reference half-cell may be used as a single or double junction submersible or surface reference electrode. The intermingling reference half-cell relies on a capillary tube having a first end open to reference fluid and a second end open to test fluid wherein the small diameter of the capillary tube limits free motion of fluid within the capillary to diffusion. The electrode is placed near the first end of the capillary in contact with the reference fluid. The method of operation of the present invention begins with filling the capillary tube with a reference solution. After closing the first end of the capillary, the capillary tube may be fully submerged or partially submerged with the second open end inserted into test fluid. Since the electrode is placed near the first end of the capillary, and since the test fluid may intermingle with the reference fluid through the second open end only by diffusion, this intermingling capillary reference half-cell provides a stable voltage potential for long time periods. 11 figs.

  8. Noise cancellation in magnetoencephalography and electroencephalography with isolated reference sensors

    DOE Patents [OSTI]

    Kraus, Jr., Robert H.; Espy, Michelle A.; Matlachov, Andrei; Volegov, Petr

    2010-06-01

    An apparatus measures electromagnetic signals from a weak signal source. A plurality of primary sensors is placed in functional proximity to the weak signal source with an electromagnetic field isolation surface arranged adjacent the primary sensors and between the weak signal source and sources of ambient noise. A plurality of reference sensors is placed adjacent the electromagnetic field isolation surface and arranged between the electromagnetic isolation surface and sources of ambient noise.

  9. Optical probe with reference fiber

    DOE Patents [OSTI]

    Da Silva, Luiz B.; Chase, Charles L.

    2006-03-14

    A system for characterizing tissue includes the steps of generating an emission signal, generating a reference signal, directing the emission signal to and from the tissue, directing the reference signal in a predetermined manner relative to the emission signal, and using the reference signal to compensate the emission signal. In one embodiment compensation is provided for fluctuations in light delivery to the tip of the probe due to cable motion.

  10. Reference Documents | Department of Energy

    Energy Savers [EERE]

    Reference Documents Reference Documents The following are reference documents utilized by CNS staff to perform its functions. Understanding Process Plant Schedule Slippage and Startup Costs A Review of Cost Estimation in New Technologies - Implications for Energy Process Plants Understanding Cost Growth and Performance Shortfalls in Pioneer Process Plants Pioneer Plants Study User's Manual The Formation of Pioneer Plant Projects in Chemical Processing Firms Industry Information Practices and the

  11. References | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    References U.S. Department of Energy / U.S. Nuclear Regulatory Commission Nuclear Materials Management & Safeguards System References Additional information related to the NMMSS may be located in the publications listed below. By referencing these documents, a more extensive understanding of the system may be gained. Other references extracted from DOE M 470.4-6 and used within the industry have also been included. "Agreement between the United States of America and the IAEA for the

  12. Desk Reference | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    forms of compensation for overtime work and to assist in advising and training ... Operational Plan and Desktop Reference for the Disability Employment Program The ...

  13. FAQS Reference Guide- Chemical Processing

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the February 2010 edition of DOE-STD-1176-2010, Chemical Processing Functional Area Qualification Standard.

  14. Archived Reference Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  15. Archived Reference Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Building Type: Hospital

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  17. Archived Reference Building Type: Hospital

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  18. RespbsforHQ-POCS-REDESIGN.doc

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    POINT OF CONTACT RESPONSIBILITIES FOR RECORDS MANAGEMENT PROGRAM RECORDS OFFICIAL (PRO) ... Oversee preparation of HQ RIDS, coordinate PRO approval, and maintain copies o Sole ...

  19. RespbsforHQ-POCS-REDESIGN.doc

    Energy Savers [EERE]

    POINT OF CONTACT RESPONSIBILITIES FOR RECORDS MANAGEMENT PROGRAM RECORDS OFFICIAL (PRO) (Activities that require Senior Official oversight or approval) Headquarters * Approve List...

  20. Reasonable Accommodation POCs | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Name Organization Phone E-mail Donna Friend Headquarters Policy 202-586-5880 donna.friend@hq.doe.gov Betsy Volk Acting HQ Accomodations Specialist 513-246-0581 ...

  1. Primary enzyme quantitation

    DOE Patents [OSTI]

    Saunders, G.C.

    1982-03-04

    The disclosure relates to the quantitation of a primary enzyme concentration by utilizing a substrate for the primary enzyme labeled with a second enzyme which is an indicator enzyme. Enzyme catalysis of the substrate occurs and results in release of the indicator enzyme in an amount directly proportional to the amount of primary enzyme present. By quantifying the free indicator enzyme one determines the amount of primary enzyme present.

  2. REFERENCES

    Energy Savers [EERE]

    OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULARS. Located ...ombmemorandadefault 5. DOE ORDERS, MANUALS, NOTICES, ... 5-8-01. 6. OTHER a. 32 CFR 2001.23, Classification Marking ...

  3. Appendix A: Reference case projections

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    Reference case projections by end-use sector and country grouping Table F1. Total world delivered energy consumption by end-use sector and fuel, 2011-40 (quadrillion Btu) Sector...

  4. NPS Quick Reference Guide | Open Energy Information

    Open Energy Info (EERE)

    Quick Reference Guide Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- OtherOther: NPS Quick Reference GuideLegal Abstract NPS Quick Reference...

  5. Safeguards and Security Program References

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2005-08-26

    The manual establishes definitions for terms related to the Department of Energy Safeguards and Security (S&S) Program and includes lists of references and acronyms/abbreviations applicable to S&S Program directives. Cancels the Safeguards and Security Glossary of Terms, dated 12-18-95. Current Safeguards and Security Program References can also be found at Safeguards and Security Policy Information Resource (http://pir.pnl.gov/)

  6. Appendix A: Reference case projections

    Gasoline and Diesel Fuel Update (EIA)

    G Projections of petroleum and other liquids production in three cases * Reference * High Oil Price * Low Oil Price This page inTenTionally lefT blank 85 U.S. Energy Information Administration | International Energy Outlook 2016 Projections of petroleum and other liquid fuels production in three cases Table G1. World petroleum and other liquids production by region and country, Reference case, 2011-40 (million barrels per day, unless otherwise noted) Region/country History (estimates)

  7. Appendix A: Reference case projections

    Gasoline and Diesel Fuel Update (EIA)

    9 U.S. Energy Information Administration | International Energy Outlook 2016 Reference case projections Table A14. World population by region, Reference case, 2011-40 (millions) Region History Projections Average annual percent change, 2012-40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas 484 489 523 544 564 581 597 0.7 United States a 312 315 334 347 359 370 380 0.7 Canada 34 35 38 39 41 43 44 0.8 Mexico and Chile 137 139 151 158 164 169 173 0.8 OECD Europe 548 550 565 571 576 579 581

  8. Document Number Q0029500 References

    Office of Legacy Management (LM)

    References 7.0 References 10 CFR 1021. U.S. Department of Energy, "National Environmental Policy Act Implementing Procedures," Code of Federal Regzilations, January 1,2003. 10 CFR 1022. U.S. Department of Energy, "Compliance with Floodplain/Wetlands Environmental Review Requirements," Code ofFederal Regulations, January 1,2003. 33 CFR 323. Corps of Engineers, Department of the Army, "Permits for Discharges of Dredged or Fill Material Into Waters of the United

  9. Draft SPD Supplemental EIS Master Reference List | National Nuclear

    National Nuclear Security Administration (NNSA)

    Security Administration Draft SPD Supplemental EIS Master Reference List References for Chapters 1 - 5 References for Appendix A References for Appendix B References for Appendix C References for Appendix D References for Appendix E References for Appendix F References for Appendix G References for Appendix H References for Appendix I References for Appendix J References for Summary Learn More SPD SEIS References for Appendix J SPD SEIS Summary References SPD SEIS References for Chapters 1 -

  10. Appendix E References | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    E References Crosswalk of Appendix E References to Main DSEIS Reference File name (Main DSEIS) or file name in Appendix E folder DOE (U.S. Department of Energy) 1999. Final ...

  11. Category:Buildings References | Open Energy Information

    Open Energy Info (EERE)

    Buildings References Jump to: navigation, search Add a new Reference Pages in category "Buildings References" The following 16 pages are in this category, out of 16 total. B Bureau...

  12. Category:Water References | Open Energy Information

    Open Energy Info (EERE)

    Water References Jump to: navigation, search Add a new Reference Pages in category "Water References" The following 22 pages are in this category, out of 22 total. A Alaska AS...

  13. Category:Hydrogen References | Open Energy Information

    Open Energy Info (EERE)

    Hydrogen References Jump to: navigation, search Add a new Reference Pages in category "Hydrogen References" The following 6 pages are in this category, out of 6 total. F FERC Order...

  14. Appendix A: Reference case projections

    U.S. Energy Information Administration (EIA) Indexed Site

    International Energy Outlook 2016 Reference case projections Table A4. World gross domestic product (GDP) by region expressed in market exchange rates, Reference case, 2011-40 (billion 2010 dollars) Region History Projections Average annual percent change, 2012-40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas 18,006 18,440 22,566 25,585 28,757 32,166 36,120 2.4 United States a 15,021 15,369 18,801 21,295 23,894 26,659 29,898 2.4 Canada 1,662 1,694 2,024 2,240 2,470 2,730 3,012 2.1 Mexico

  15. Appendix A: Reference case projections

    U.S. Energy Information Administration (EIA) Indexed Site

    U.S. Energy Information Administration | International Energy Outlook 2016 Reference case projections Table A6. World natural gas consumption by region, Reference case, 2011-40 (trillion cubic feet) Region History Projections Average annual percent change, 2012-40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas 30.8 31.8 32.8 34.3 36.5 38.2 40.1 0.8 United States a 24.5 25.5 26.1 26.9 28.1 28.8 29.7 0.5 Canada 3.7 3.7 3.9 4.2 4.7 5.2 5.6 1.5 Mexico and Chile 2.6 2.6 2.8 3.2 3.6 4.2 4.8

  16. Energy reference handbook. Third edition

    SciTech Connect (OSTI)

    Not Available

    1985-01-01

    The energy field has exploded since the OPEC oil embargo of 1973. Terms that did not even exist several years ago are now being used. In addition, many words have developed interpretations somewhat different from their commonly accepted meanings. The 3rd Edition of the Energy Reference Handbook records and standardizes these terms in a comprehensive glossary. Special emphasis is placed on providing terms and definitions in the area of alternative fuels-synthetics from coal and oil shale; solar; wind; biomass; geothermal; and more - as well as traditional fossil fuels. In total, more than 3,500 terms, key words, and phrases used daily in energy literature are referenced. In addition to these definitions, conversion tables, diagrams, maps, tables, and charts on various aspects of energy which forecast the reserves of fuel resources, plus other information relevant to energy resources and technologies are found in this reference.

  17. Appendix A: Reference case projections

    Gasoline and Diesel Fuel Update (EIA)

    1 U.S. Energy Information Administration | International Energy Outlook 2016 Reference case projections for natural gas production Table I1. World total natural gas production by region, Reference case, 2012-40 (trillion cubic feet) Region/country Projections Average annual percent change, 2012-40 2012 2020 2025 2030 2035 2040 OECD OECD Americas 31.8 35.7 38.6 42.1 44.6 47.3 1.4 United States a 24.0 28.7 30.4 32.9 34.0 35.3 1.4 Canada 6.1 5.8 6.6 7.2 7.9 8.6 1.2 Mexico 1.7 1.2 1.5 2.0 2.6 3.3

  18. HANFORD WASTE MINERALOGY REFERENCE REPORT

    SciTech Connect (OSTI)

    DISSELKAMP RS

    2010-06-29

    This report lists the observed mineral phases present in the Hanford tanks. This task was accomplished by performing a review of numerous reports that used experimental techniques including, but not limited to: x-ray diffraction, polarized light microscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, electron energy loss spectroscopy, and particle size distribution analyses. This report contains tables that can be used as a quick reference to identify the crystal phases observed in Hanford waste.

  19. HANFORD WASTE MINEROLOGY REFERENCE REPORT

    SciTech Connect (OSTI)

    DISSELKAMP RS

    2010-06-18

    This report lists the observed mineral phase phases present in the Hanford tanks. This task was accomplished by performing a review of numerous reports using experimental techniques including, but not limited to: x-ray diffraction, polarized light microscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, electron energy loss spectroscopy, and particle size distribution analyses. This report contains tables that can be used as a quick reference to identify the crystal phases present observed in Hanford waste.

  20. Appendix A: Reference case projections

    Gasoline and Diesel Fuel Update (EIA)

    J Kaya Identity factor projections * Carbon dioxide intensity * Energy intensity * GDP per capita * Population This page inTenTionally lefT blank 127 U.S. Energy Information Administration | International Energy Outlook 2016 Kaya Identity factor projections Table J1. World carbon dioxide intensity of energy use by region, Reference case, 2011-40 (metric tons per billion Btu) Region History Projections Average annual percent change, 2012-40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas

  1. Microgrid cyber security reference architecture.

    SciTech Connect (OSTI)

    Veitch, Cynthia K.; Henry, Jordan M.; Richardson, Bryan T.; Hart, Derek H.

    2013-07-01

    This document describes a microgrid cyber security reference architecture. First, we present a high-level concept of operations for a microgrid, including operational modes, necessary power actors, and the communication protocols typically employed. We then describe our motivation for designing a secure microgrid; in particular, we provide general network and industrial control system (ICS)-speci c vulnerabilities, a threat model, information assurance compliance concerns, and design criteria for a microgrid control system network. Our design approach addresses these concerns by segmenting the microgrid control system network into enclaves, grouping enclaves into functional domains, and describing actor communication using data exchange attributes. We describe cyber actors that can help mitigate potential vulnerabilities, in addition to performance bene ts and vulnerability mitigation that may be realized using this reference architecture. To illustrate our design approach, we present a notional a microgrid control system network implementation, including types of communica- tion occurring on that network, example data exchange attributes for actors in the network, an example of how the network can be segmented to create enclaves and functional domains, and how cyber actors can be used to enforce network segmentation and provide the neces- sary level of security. Finally, we describe areas of focus for the further development of the reference architecture.

  2. Subsurface Knowledge Reference Page | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    The below listing provides additional references related to Subsurface & Groundwater Remediation. The references are categorized by documents types (e.g., Strategic Plans, ...

  3. A New Solar Irradiance Reference Spectrum

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    A New Solar Irradiance Reference Spectrum Pilewskie, Peter University of Colorado ... We describe the development of a new solar reference spectrum for radiation and climate ...

  4. Template:ReferenceMaterial | Open Energy Information

    Open Energy Info (EERE)

    - The type of reference material (allowable values include: Journal article, Book, Report, etc.) Documentnumber - The reference material document number or DOI...

  5. Reference Inflow Characterization for River Resource Reference Model (RM2)

    SciTech Connect (OSTI)

    Neary, Vincent S [ORNL

    2011-12-01

    Sandia National Laboratory (SNL) is leading an effort to develop reference models for marine and hydrokinetic technologies and wave and current energy resources. This effort will allow the refinement of technology design tools, accurate estimates of a baseline levelized cost of energy (LCoE), and the identification of the main cost drivers that need to be addressed to achieve a competitive LCoE. As part of this effort, Oak Ridge National Laboratory was charged with examining and reporting reference river inflow characteristics for reference model 2 (RM2). Published turbulent flow data from large rivers, a water supply canal and laboratory flumes, are reviewed to determine the range of velocities, turbulence intensities and turbulent stresses acting on hydrokinetic technologies, and also to evaluate the validity of classical models that describe the depth variation of the time-mean velocity and turbulent normal Reynolds stresses. The classical models are found to generally perform well in describing river inflow characteristics. A potential challenge in river inflow characterization, however, is the high variability of depth and flow over the design life of a hydrokinetic device. This variation can have significant effects on the inflow mean velocity and turbulence intensity experienced by stationary and bottom mounted hydrokinetic energy conversion devices, which requires further investigation, but are expected to have minimal effects on surface mounted devices like the vertical axis turbine device designed for RM2. A simple methodology for obtaining an approximate inflow characterization for surface deployed devices is developed using the relation umax=(7/6)V where V is the bulk velocity and umax is assumed to be the near-surface velocity. The application of this expression is recommended for deriving the local inflow velocity acting on the energy extraction planes of the RM2 vertical axis rotors, where V=Q/A can be calculated given a USGS gage flow time-series and stage vs. cross-section area rating relationship.

  6. PVWatts Version 1 Technical Reference

    SciTech Connect (OSTI)

    Dobos, A. P.

    2013-10-01

    The NREL PVWatts(TM) calculator is a web application developed by the National Renewable Energy Laboratory (NREL) that estimates the electricity production of a grid-connected photovoltaic system based on a few simple inputs. PVWatts combines a number of sub-models to predict overall system performance, and makes several hidden assumptions about performance parameters. This technical reference details the individual sub-models, documents assumptions and hidden parameters, and explains the sequence of calculations that yield the final system performance estimation.

  7. Reference electrode for electrolytic cell

    DOE Patents [OSTI]

    Kessie, R.W.

    1988-07-28

    A reference electrode device is provided for a high temperature electrolytic cell used to electrolytically recover uranium from spent reactor fuel dissolved in an anode pool, the device having a glass tube to enclose the electrode and electrolyte and serve as a conductive membrane with the cell electrolyte, and an outer metal tube about the glass tube to serve as a shield and basket for any glass sections broken by handling of the tube to prevent their contact with the anode pool, the metal tube having perforations to provide access between the bulk of the cell electrolyte and glass membrane. 4 figs.

  8. Appendix A: Reference case projections

    Gasoline and Diesel Fuel Update (EIA)

    7 U.S. Energy Information Administration | International Energy Outlook 2016 Reference case projections for electricity capacity and generation by fuel Table H1. World total installed generating capacity by region and country, 2011-40 (gigawatts) Region/country History Projections Average annual percent change, 2012-40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas 1,258 1,278 1,330 1,371 1,436 1,517 1,622 0.9 United States a 1,046 1,063 1,079 1,091 1,133 1,187 1,261 0.6 Canada 133 135

  9. Emergency Responder Radioactive Material Quick Reference Sheet

    Broader source: Energy.gov [DOE]

    Transportation Emergency Preparedness Program (TEPP) Emergency Responder Radioactive Material Quick Reference Sheet

  10. High stability wavefront reference source

    DOE Patents [OSTI]

    Feldman, M.; Mockler, D.J.

    1994-05-03

    A thermally and mechanically stable wavefront reference source which produces a collimated output laser beam is disclosed. The output beam comprises substantially planar reference wavefronts which are useful for aligning and testing optical interferometers. The invention receives coherent radiation from an input optical fiber, directs a diverging input beam of the coherent radiation to a beam folding mirror (to produce a reflected diverging beam), and collimates the reflected diverging beam using a collimating lens. In a class of preferred embodiments, the invention includes a thermally and mechanically stable frame comprising rod members connected between a front end plate and a back end plate. The beam folding mirror is mounted on the back end plate, and the collimating lens mounted to the rods between the end plates. The end plates and rods are preferably made of thermally stable metal alloy. Preferably, the input optical fiber is a single mode fiber coupled to an input end of a second single mode optical fiber that is wound around a mandrel fixedly attached to the frame of the apparatus. The output end of the second fiber is cleaved so as to be optically flat, so that the input beam emerging therefrom is a nearly perfect diverging spherical wave. 7 figures.

  11. High stability wavefront reference source

    DOE Patents [OSTI]

    Feldman, Mark; Mockler, Daniel J.

    1994-01-01

    A thermally and mechanically stable wavefront reference source which produces a collimated output laser beam. The output beam comprises substantially planar reference wavefronts which are useful for aligning and testing optical interferometers. The invention receives coherent radiation from an input optical fiber, directs a diverging input beam of the coherent radiation to a beam folding mirror (to produce a reflected diverging beam), and collimates the reflected diverging beam using a collimating lens. In a class of preferred embodiments, the invention includes a thermally and mechanically stable frame comprising rod members connected between a front end plate and a back end plate. The beam folding mirror is mounted on the back end plate, and the collimating lens mounted to the rods between the end plates. The end plates and rods are preferably made of thermally stable metal alloy. Preferably, the input optical fiber is a single mode fiber coupled to an input end of a second single mode optical fiber that is wound around a mandrel fixedly attached to the frame of the apparatus. The output end of the second fiber is cleaved so as to be optically flat, so that the input beam emerging therefrom is a nearly perfect diverging spherical wave.

  12. Appendix A: Reference case projections

    U.S. Energy Information Administration (EIA) Indexed Site

    8 Appendix A Table A3. World gross domestic product (GDP) by region expressed in purchasing power parity, Reference case, 2011-40 (billion 2010 dollars) Region History Projections Average annual percent change, 2012-40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas 18,616 19,080 23,390 26,577 29,942 33,569 37,770 2.5 United States a 15,021 15,369 18,801 21,295 23,894 26,659 29,898 2.4 Canada 1,396 1,422 1,700 1,881 2,074 2,293 2,529 2.1 Mexico and Chile 2,200 2,288 2,890 3,400 3,974 4,618

  13. Appendix A: Reference case projections

    Gasoline and Diesel Fuel Update (EIA)

    E Low Oil Price case projections This page inTenTionally lefT blank 57 U.S. Energy Information Administration | International Energy Outlook 2016 Low Oil Price case projections Table E1. World total primary energy consumption by region, Low Oil Price case, 2011-40 (quadrillion Btu) Region History Projections Average annual percent change, 2012-s40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas 120.6 118.1 126.5 129.2 131.8 135.0 138.9 0.6 United States a 96.8 94.4 101.2 102.7 103.6 104.6

  14. Appendix A: Reference case projections

    Gasoline and Diesel Fuel Update (EIA)

    7 U.S. Energy Information Administration | International Energy Outlook 2016 Low Economic Growth case projections Table C1. World total primary energy consumption by region, Low Economic Growth case, 2011-40 (quadrillion Btu) Region History Projections Average annual percent change, 2012-40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas 120.6 118.1 123.3 123.9 124.7 126.3 128.8 0.3 United States a 96.8 94.4 98.7 98.1 97.5 97.4 98.0 0.1 Canada 14.5 14.5 15.0 15.4 15.9 16.6 17.3 0.6 Mexico

  15. Form:Reference | Open Energy Information

    Open Energy Info (EERE)

    The reference title should match the book title. e.g.- Where the Wild Things Are Book Review Used when citing a review of a book. The reference title should include "Review of the...

  16. Appendix A: Reference case projections

    U.S. Energy Information Administration (EIA) Indexed Site

    6 Appendix A Table A2. World total energy consumption by region and fuel, Reference case, 2011-40 (quadrillion Btu) Region History Projections Average annual percent change, 2012-40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas Liquids 45.3 44.6 46.4 46.1 46.0 46.2 46.7 0.2 Natural gas 31.8 32.8 33.9 35.5 37.7 39.5 41.4 0.8 Coal 21.0 18.7 20.3 20.5 20.1 20.0 20.0 0.2 Nuclear 9.4 9.2 9.5 9.4 9.5 9.5 9.7 0.2 Other 13.1 12.9 15.6 16.6 17.5 18.6 20.3 1.6 Total 120.6 118.1 125.7 128.1 130.7

  17. Appendix A: Reference case projections

    U.S. Energy Information Administration (EIA) Indexed Site

    30 Appendix A Table A5. World liquids consumption by region, Reference case, 2011-40 (million barrels per day) Region History Projections Average annual percent change, 2012-40 2011 2012 2020 2025 2030 2035 2040 OECD OECD Americas 23.6 23.2 24.4 24.4 24.3 24.4 24.6 0.2 United States a 18.9 18.5 19.6 19.6 19.4 19.3 19.3 0.2 Canada 2.3 2.4 2.4 2.4 2.4 2.4 2.5 0.2 Mexico and Chile 2.4 2.4 2.4 2.4 2.5 2.7 2.9 0.6 OECD Europe 14.5 14.1 13.7 13.6 13.7 13.8 14.0 0.0 OECD Asia 7.9 8.2 7.7 7.5 7.5 7.5

  18. Research Notes and Information References

    Energy Science and Technology Software Center (OSTI)

    1994-12-01

    The RNS (Research Notes System) is a set of programs and databases designed to aid the research worker in gathering, maintaining, and using notes taken from the literature. The sources for the notes can be books, journal articles, reports, private conversations, conference papers, audiovisuals, etc. The system ties the databases together in a relational structure, thus eliminating data redundancy while providing full access to all the information. The programs provide the means for access andmore » data entry in a way that reduces the key-entry burden for the user. Each note has several data fields. Included are the text of the note, the subject classification (for retrieval), and the reference identification data. These data are divided into four databases: Document data - title, author, publisher, etc., fields to identify the article within the document; Note data - text and page of the note; Sublect data - subject categories to ensure uniform spelling for searches. Additionally, there are subsidiary files used by the system, including database index and temporary work files. The system provides multiple access routes to the notes, both structurally (access method) and topically (through cross-indexing). Output may be directed to a printer or saved as a file for input to word processing software.« less

  19. Laminar burning velocities at high pressure for primary reference fuels and gasoline: Experimental and numerical investigation

    SciTech Connect (OSTI)

    Jerzembeck, S.; Peters, N. [RWTH, Aachen (Germany); Pepiot-Desjardins, P.; Pitsch, H. [Department of Mechanical Engineering, Stanford University, CA (United States)

    2009-02-15

    Spherical flames of n-heptane, iso-octane, PRF 87 and gasoline/air mixtures are experimentally investigated to determine laminar burning velocities and Markstein lengths under engine-relevant conditions by using the constant volume bomb method. Data are obtained for an initial temperature of 373 K, equivalence ratios varying from {phi}=0.7 to {phi}=1.2, and initial pressures from 10 to 25 bar. To track the flame front in the vessel a dark field He-Ne laser Schlieren measurement technique and digital image processing were used. The propagating speed with respect to the burned gases and the stretch rate are determined from the rate of change of the flame radius. The laminar burning velocities are obtained through a linear extrapolation to zero stretch. The experimentally determined Markstein numbers are compared to theoretical predictions. A reduced chemical kinetic mechanism for n-heptane and iso-octane was derived from the Lawrence Livermore comprehensive mechanisms. This mechanism was validated for ignition delay times and flame propagation at low and high pressures. In summary an overall good agreement with the various experimental data sets used in the validation was obtained. (author)

  20. FAQS Reference Guide – Industrial Hygiene

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the November 2007 edition of DOE-STD-1138-2007, Industrial Hygiene Functional Area Qualification Standard.

  1. FAQS Reference Guide – Mechanical Systems

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the June 2008 edition of DOE-STD-1161-2008, Mechanical Systems Functional Area Qualification Standard.

  2. FAQS Reference Guide – Facility Maintenance Management

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the April 2014 edition of DOE Standard DOE-STD-1181-2014, Facility Maintenance Management Functional Area Qualification Standard.

  3. FAQS Reference Guide – Criticality Safety (NNSA)

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in DOE-STD-1173-2009, Criticality Safety Functional Area Qualification Standard.

  4. AVIATION MANAGER QUALIFICATION STANDARD REFERENCE GUIDE

    Energy Savers [EERE]

    Manager Qualification Standard Reference Guide MARCH 2010 i This page is intentionally blank. Table of Contents ii LIST OF FIGURES ..................................................................................................................... iii LIST OF TABLES ....................................................................................................................... iii ACRONYMS

  5. AVIATION SAFETY OFFICER QUALIFICATION STANDARD REFERENCE GUIDE

    Energy Savers [EERE]

    Safety Officer Qualification Standard Reference Guide MARCH 2010 i This page is intentionally blank. Table of Contents ii LIST OF FIGURES ..................................................................................................................... iii LIST OF TABLES ....................................................................................................................... iii ACRONYMS

  6. FAQS Reference Guide – Environmental Compliance

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the June 2011 edition of DOE-STD-1156-2011, Environmental Compliance Functional Area Qualification Standard.

  7. Reference Designs for Hydrogen Fueling Stations Webinar

    Broader source: Energy.gov [DOE]

    Access the recording and download the presentation slides from the Fuel Cell Technologies Office webinar "Reference Designs for Hydrogen Fueling Stations" held on October 13, 2015.

  8. FAQS Reference Guide – Criticality Safety

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the April 2009 edition of DOE-STD-1173-2009, Criticality Safety Functional Area Qualification Standard.

  9. FAQS Reference Guide – Emergency Management

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the January 2004 edition of DOE-STD-1177-2004, Emergency Management Functional Area Qualification Standard.

  10. FAQS Reference Guide – Safeguards and Security

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the May 2009 edition of DOE-STD-1171-2009, Safeguards and Security Functional Area Qualification Standard.

  11. FAQS Reference Guide – Fire Protection Engineering

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the December 2007 edition of DOE-STD-1137-2007, Fire Protection Engineering Functional Area Qualification Standard.

  12. Property:ReferenceGenre | Open Energy Information

    Open Energy Info (EERE)

    Property Type Text Description The genre or subcategory label of reference material. Allows Values Buildings;Bulk Transmission;Geothermal;Hydrogen;Hydropower;Smart...

  13. FAQS Reference Guide – Facility Representative

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the October 2010 edition of DOE-STD-1151-2010, Facility Representative Functional Area Qualification Standard.

  14. Commercial Reference Buildings | Open Energy Information

    Open Energy Info (EERE)

    Reference Building Types1 , which represent approximately 70% of the commercial buildings in the U.S. 2. Whole building energy analysis data (developed using EnergyPlus...

  15. FAQS Reference Guide – Construction Management

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the March 2004 edition of DOE-STD-1180-2004, Construction Management Functional Area Qualification Standard.

  16. FAQS Reference Guide – General Technical Base

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the December 2007 edition of DOE-STD-1146-2007, General Technical Base Functional Area Qualification Standard.

  17. Template:Reference | Open Energy Information

    Open Energy Info (EERE)

    for references that may not require listed authors such as technical reports or web referenced material (Report & Web Site) GraphicAuthor - List of authors or map...

  18. Manufacturing Energy and Carbon Footprint References

    Broader source: Energy.gov (indexed) [DOE]

    References AMO (Advanced Manufacturing Office), EERE (Energy Efficiency and Renewable Energy). 2012. Consider Installing High-Pressure Boilers with Backpressure Turbine-Generators. ...

  19. FAQS Reference Guide – Environmental Restoration

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the November 2002 edition of DOE-STD-1157-2002, Environmental Restoration Functional Area Qualification Standard.

  20. Reference Form | SREL REU in Radioecology

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to highlight specific examples that illustrate the candidate's strengths or suitability to the program. Therefore, we also require references to also upload a letter of...

  1. IBM References | Argonne Leadership Computing Facility

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Feedback Form IBM References Contents IBM Redbooks A2 Processor Manual QPX Vector Instruction Set Architecture XL Compiler Documentation MASS Documentation Back to top IBM...

  2. Archived Reference Climate Zone: 7 Duluth, Minnesota

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  3. Archived Reference Climate Zone: 7 Duluth, Minnesota

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  4. References - DOE Directives, Delegations, and Requirements

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    References by Website Administrator This page provides information and links to references. Technical Standards Technical Standards Program Technical Standards Home RevCom for Technical Standards Review Process for Technical Standards of Interest to the Directives Program Technical Standards Crosswalk NNSA Directives National Nuclear Security Administration (NNSA) Supplemental Directives NNSA Policies (NAPs) FAR Federal Acquisition Regulations Federal Acquisition Regulations (FAR) DOE

  5. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  6. Archived Reference Climate Zone: 8 Fairbanks, Alaska

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zonesis available for reference.Current versionsare also available.

  7. Archived Reference Climate Zone: 8 Fairbanks, Alaska

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  8. Archived Reference Building Type: Quick service restaurant

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  9. Archived Reference Building Type: Full service restaurant

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  10. Archived Reference Building Type: Quick service restaurant

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  11. Archived Reference Building Type: Full service restaurant

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  12. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  13. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  14. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  15. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Building Type: Large Hotel

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  17. Archived Reference Building Type: Small Hotel

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  18. Archived Reference Building Type: Small Hotel

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  19. Archived Reference Building Type: Large Hotel

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  20. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  1. Archived Reference Building Type: Strip mall

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zonesis available for reference.Current versionsare also available.

  2. Archived Reference Building Type: Strip mall

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  3. Archived Reference Building Type: Midrise Apartment

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zonesis available for reference.Current versionsare also available.

  4. Archived Reference Building Type: Midrise Apartment

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  5. FAQS Reference Guide - Aviation Manager | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    FAQS Reference Guide - Aviation Manager FAQS Reference Guide - Aviation Manager This reference guide addresses the competency statements in the January 2010 edition of...

  6. FAQS Reference Guide – Nuclear Safety Specialist

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the November 2007 edition of DOE Standard DOE-STD-1183-2007, Nuclear Safety Specialist Functional Area Qualification Standard.

  7. Archive Reference Buildings by Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  8. FAQS Reference Guide – Occupational Safety

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the July 2011 version of DOE-STD-1160-2011, Occupational Safety Functional Area Qualification Standard.

  9. New Construction Commercial Reference Buildings — Archive

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  10. FAQS Reference Guide –Radiation Protection

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the December 2003 edition of DOE-STD-1174-2003, Radiation Protection Functional Area Qualification Standard.

  11. FAQS Reference Guide – Instrumentation and Control

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the June 2013 edition of DOE-Standard (STD)-1162-2013, Instrumentation and Control Functional Area Qualification Standard.

  12. Webinar: Reference Designs for Hydrogen Fueling Stations

    Broader source: Energy.gov [DOE]

    The Fuel Cell Technologies Office will present a live webinar titled "Reference Designs for Hydrogen Fueling Stations" on Tuesday, October 13, from 12 to 1 p.m. Eastern Daylight Time (EDT).

  13. FAQS Reference Guide – Civil/ Structural Engineering

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the March 2004 edition of DOE-STD-1182-2004, Civil/Structural Engineering Functional Area Qualification Standard.

  14. New Robust References! | OpenEI Community

    Open Energy Info (EERE)

    provided document type If I,Robot doesn't exist yet, the template will return a red link specially coded to open in the Reference form so that it can be easily added...

  15. Emergency Responder Radioactive Material Quick Reference Sheet

    Broader source: Energy.gov [DOE]

    This job aid is a quick reference to assist emergency responders in identifying preliminary safety precautions that should be taken during the initial response phase after arrival at the scene of...

  16. Template:ReferenceHeader | Open Energy Information

    Open Energy Info (EERE)

    Reference Library banner, typically across the top of the page, which features a unique color scheme and simple menu. Parameters none Usage It should be called in the following...

  17. "Analysis of SOFCs using reference electrodes?

    SciTech Connect (OSTI)

    Finklea, Harry; Chen,Xiaoke; Gerdes,Kirk; Pakalapati, Suryanarayana; Celik, Ismail

    2013-07-01

    Reference electrodes are frequently applied to isolate the performance of one electrode in a solid oxide fuel cell. However, reference electrode simulations raise doubt to veracity of data collected using reference electrodes. The simulations predict that the reported performance for the one electrode will frequently contain performance of both electrodes. Nonetheless, recent reports persistently treat data so collected as ideally isolated. This work confirms the predictions of the reference electrode simulations on two SOFC designs, and to provides a method of validating the data measured in the 3-electrode configuration. Validation is based on the assumption that a change in gas composition to one electrode does not affect the impedance of the other electrode at open circuit voltage. This assumption is supported by a full physics simulation of the SOFC. Three configurations of reference electrode and cell design are experimentally examined using various gas flows and two temperatures. Impedance data are subjected to deconvolution analysis and equivalent circuit fitting and approximate polarization resistances of the cathode and anode are determined. The results demonstrate that the utility of reference electrodes is limited and often wholly inappropriate. Reported impedances and single electrode polarization values must be scrutinized on this basis.

  18. TriBITS Developers Guide and Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    tsstart-1327-gca8bb07 Abstract: This document describes the usage of TriBITS to build, test, and deploy complex software. The primary audience are those individuals who develop on...

  19. Development of solid radium-226 reference materials

    SciTech Connect (OSTI)

    Chessmore, R.B.; Engelder, P.R.; Sill, C.W.

    1983-11-01

    Radium-226 reference materials having a matrix similar to soil or tailings samples are not available in sufficient quantity for use by remedial-action contractors to calibrate their laboratory gamma-ray spectrometers. Such reference materials are needed to provide uniform standardization among measurements made by remedial-action contractors. A task, therefore, was undertaken to prepare about 200 pounds each of three different concentrations of radium-226 reference materials by diluting tailings with high-purity silica. Target values for radium-226 content were 50, 15, and 5 pCi/g. The radium-226 content of the reference materials was measured by C.W. Sill of EG and G Idaho, Inc., Idaho Falls, using a high- resolution alpha spectrometry technique standardized with National Bureau of Standards (NBS) standard 4961. A summary of this technique is provided in Appendix A of this report. An independent measurement of the radium-226 content was conducted by Bendix Field Engineering Corporation (Bendix), Grand Junction, Colorado, using a high-resolution Ge(Li) detector, which was calibrated using the New Brunswick Laboratory (NBL) 100-A Series standards. The Ge(Li) detector has also been used to determine the radium-226 content in the calibration models at the Grand Junction facility; these models are used by remedial-action contractors for calibration of borehole logging gamma-ray probes. 8 references, 12 tables.

  20. Positional reference system for ultraprecision machining

    DOE Patents [OSTI]

    Arnold, Jones B.; Burleson, Robert R.; Pardue, Robert M.

    1982-01-01

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of position interferometers and part contour description data inputs to calculate error components for each axis of movement and output them to corresponding axis drives with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  1. Positional reference system for ultraprecision machining

    DOE Patents [OSTI]

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1980-09-12

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  2. Xyce parallel electronic simulator : reference guide.

    SciTech Connect (OSTI)

    Mei, Ting; Rankin, Eric Lamont; Thornquist, Heidi K.; Santarelli, Keith R.; Fixel, Deborah A.; Coffey, Todd Stirling; Russo, Thomas V.; Schiek, Richard Louis; Warrender, Christina E.; Keiter, Eric Richard; Pawlowski, Roger Patrick

    2011-05-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide. The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. It is targeted specifically to run on large-scale parallel computing platforms but also runs well on a variety of architectures including single processor workstations. It also aims to support a variety of devices and models specific to Sandia needs. This document is intended to complement the Xyce Users Guide. It contains comprehensive, detailed information about a number of topics pertinent to the usage of Xyce. Included in this document is a netlist reference for the input-file commands and elements supported within Xyce; a command line reference, which describes the available command line arguments for Xyce; and quick-references for users of other circuit codes, such as Orcad's PSpice and Sandia's ChileSPICE.

  3. SBOT TENNESSEE OAK RIDGE INSTITUTE SCIENCE AND EDUCATION POC

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Miscellaneous Chemical Product and Preparation ... Services 541370 Graphic Design Services 541430 Other ... 541618 Research and Development in Biotechnology 541711 ...

  4. POCs for Secretarial Offices and Management and Performance ...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Tyesha Bennett 202-586-1444 Tyesha.bennett@hq.doe.gov Shane Humphreys 202-586-9661 Shane.Humpherys@hq.doe.gov Cathlyne Smith 202-586-7384 Cathlyne.Smith@hq.doe.gov Tania Burkley ...

  5. Microsoft Word - M110 POC Change.DOC

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    TO AMENDMENTS OF SOLICITATIONS The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not...

  6. GOODS CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone

    Energy Savers [EERE]

    Department of Energy GNEP Element:Demonstrate More Proliferation-Resistant Recycling GNEP Element:Demonstrate More Proliferation-Resistant Recycling An article describing GNEP element of recycling. PDF icon GNEP Element:Demonstrate More Proliferation-Resistant Recycling More Documents & Publications GNEP Element:Develop Enhanced Nuclear Safeguards Global Nuclear Energy Partnership Fact Sheet - Develop Enhanced Nuclear Safeguards Global Nuclear Energy Partnership Fact Sheet - Demonstrate

  7. SBOT CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Related Equipment Merchant Wholesalers 423610 Electrical and Electronic Appliance, Television, and Radio Set Merchant Wholesalers 423620 Other Electronic Parts and Equipment...

  8. SBOT IOWA AMES LAB POC Lisa Rodgers Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Related Equipment Merchant Wholesalers 423610 Electrical and Electronic Appliance, Television, and Radio Set Merchant Wholesalers 423620 Other Electronic Parts and Equipment...

  9. Microsoft Word - M110 POC Change.DOC

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    county, State and ZIP code) 9A. AMENDMENT OF SOLICITATION NO. Bechtel National, Inc. 2435 Stevens Center Place 9B. DATED (SEE ITEM 11) Richland, WA 99352 10A. MODIFICATION OF...

  10. SBOT VIRGINIA THOMAS JEFFERSON LAB POC Danny Llyod Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Packaging Film and Sheet (including Laminated) Manufacturing 326112 Plastics Pipe and Pipe Fitting Manufacturing 326122 Laminated Plastics Plate, Sheet (except Packaging), ...

  11. SBOT NEW JERSEY PRINCETON PLASMA LAB POC Arlene White Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Packaging Film and Sheet (including Laminated) Manufacturing 326112 Plastics Pipe and Pipe Fitting Manufacturing 326122 Laminated Plastics Plate, Sheet (except Packaging), ...

  12. SBOT WASHINGTON PACIFIC NORTHWEST LAB POC Kerry T. Bass Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ADMINISTATIVE WASTE REMEDIATION Facilities Support Services 561210 Employment Placement Agencies 561311 Temporary Help Services 561320 Professional Employer Organizations ...

  13. SBOT COLORADO GOLDEN FIELD OFFICE POC Karen Downs Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ADMINISTATIVE WASTE REMEDIATION Facilities Support Services 561210 Employment Placement Agencies 561311 Temporary Help Services 561320 Professional Employer Organizations ...

  14. SBOT MISSOURI KANSAS CITY PLANT POC C. J. Warrick Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Locksmiths 561622 Exterminating and Pest Control Services 561710 Janitorial Services ... Other Fuel Dealers 454319 HEALTH CARE & SOCIAL ASSISTANCE Outpatient Mental Health and ...

  15. SBOT NEVADA NEVADA SITE OFFICE POC Anita Ross Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Locksmiths 561622 Exterminating and Pest Control Services 561710 Janitorial Services ... Business Utilization HEALTH CARE & SOCIAL ASSISTANCE Freestanding Ambulatory ...

  16. SBOT DIST OF COLUMBIA HEADQUARTERS PROCUREMENT POC Michael Raizen

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Construction 236220 Water and Sewer Line and Related ... Other Heavy and Civil Engineering Construction 237990 ... Deep Sea Freight Transportation 483111 Inland Water Freight ...

  17. SBOT OHIO EM BUSINESS CENTER POC Karen Bahan Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Construction 236220 Water and Sewer Line and Related ... Other Heavy and Civil Engineering Construction 237990 ... Deep Sea Freight Transportation 483111 Inland Water Freight ...

  18. SBOT WYOMING ROCKY MOUNTAIN OILFIELD CENTER POC Jenny Krom Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    237110 Oil and Gas Pipeline and Related Structures Construction 237120 Power and Communication Line and Related Structures Construction 237130 Highway, Street, and Bridge ...

  19. SBOT GEORGIA SOUTHEASTERN POWER ADMIN POC Ann Craft Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    236220 Water and Sewer Line and Related Structures Construction 237110 Power and Communication Line and Related Structures Construction 237130 Other Heavy and Civil Engineering ...

  20. SBOT PENNSYLVANIA NATIONAL ENERGY TECHNOLOGY LAB - PA POC Larry...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... 928120 REAL ESTATE & EQUIPMENT LEASING RENTAL Lessors of Residential Buildings and Dwellings 531110 Lessors of Nonresidential Buildings (except Miniwarehouses) 531120 Lessors of ...

  1. SBOT WEST VIRGINIA NATIONAL ENERGY TECHNOLOGY LAB -WV POC Larry...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... 928120 REAL ESTATE & EQUIPMENT LEASING RENTAL Lessors of Residential Buildings and Dwellings 531110 Lessors of Nonresidential Buildings (except Miniwarehouses) 531120 Lessors of ...

  2. SBOT IDAHO IDAHO LAB POC Stacey Francis Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Lessors of Residential Buildings and Dwellings 531110 Other Commercial and Industrial ... Lessors of Residential Buildings and Dwellings 531110 Other Commercial and Industrial ...

  3. SBOT NEW MEXICO CARLSBAD FIELD OFFICE POC Roland Taylor Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Types) Manufacturing 333512 Pump and Pumping Equipment Manufacturing 333911 Air and ... Types) Manufacturing 333512 Pump and Pumping Equipment Manufacturing 333911 Air and ...

  4. SBOT ILLINOIS ARGONNE LAB POC Karl Duke Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Accessory Manufacturing 333515 Pump and Pumping Equipment Manufacturing 333911 Air and ... Types) Manufacturing 333512 Pump and Pumping Equipment Manufacturing 333911 Air and ...

  5. SBOT LOUISIANA STRATEGIC PETROLEUM RESERVE POC Sally Leingang

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Manufacturing 332912 Other Metal Valve and Pipe Fitting Manufacturing 332919 Pump and Pumping Equipment Manufacturing 333911 Measuring and Dispensing Pump Manufacturing 333913 ...

  6. Category:Smart Grid References | Open Energy Information

    Open Energy Info (EERE)

    Category Edit History Category:Smart Grid References Jump to: navigation, search Add a new Reference Pages in category "Smart Grid References" The following 11 pages are in this...

  7. Reference electrode for strong oxidizing acid solutions

    DOE Patents [OSTI]

    Rigdon, Lester P.; Harrar, Jackson E.; Bullock, Sr., Jack C.; McGuire, Raymond R.

    1990-01-01

    A reference electrode for the measurement of the oxidation-reduction potentials of solutions is especially suitable for oxidizing solutions such as highly concentrated and fuming nitric acids, the solutions of nitrogen oxides, N.sub.2 O.sub.4 and N.sub.2 O.sub.5, in nitric acids. The reference electrode is fabricated of entirely inert materials, has a half cell of Pt/Ce(IV)/Ce(III)/70 wt. % HNO.sub.3, and includes a double-junction design with an intermediate solution of 70 wt. % HNO.sub.3. The liquid junctions are made from Corning No. 7930 glass for low resistance and negligible solution leakage.

  8. Annual Energy Outlook 2011 Reference Case

    U.S. Energy Information Administration (EIA) Indexed Site

    October 9, 2012 | Washington, DC Annual Energy Outlook 2013: Modeling Updates in the Transportation Sector WORKING GROUP PRESENTATION FOR DISCUSSION PURPOSES DO NOT QUOTE OR CITE AS RESULTS ARE SUBJECT TO CHANGE Overview 2 * Modeling updates made to the Annual Energy Outlook 2013 Reference case * Light-duty vehicle technology updates * Heavy-duty natural gas vehicles * Preliminary results (Working group presentation for discussion purposes. Do not quote or cite as results are subject to change)

  9. References & Links | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    References & Links 48CFR Chapter 9, Acquisition Regulation (DEAR) Department of Energy Acquisition Requirements (DEAR) DOE Order 470.4B, Safeguards and Security Program DOE Order 472.2, Personnel Security DOE Order 206.2 DOE Order 470.4B Executive Order 10865 Executive Order 12968 Federal Acquisition Regulation (FAR) Federal Bureau of Investigations FIPS PUB 201-2, Personal Identity Verification (PIV) of Federal Employees and Contractors Intelligence Reform and Terrorism Prevention Act of

  10. Floating Oscillating Water Column Reference Model Completed

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Floating Oscillating Water Column Reference Model Completed - Sandia Energy Energy Search Icon Sandia Home Locations Contact Us Employee Locator Energy & Climate Secure & Sustainable Energy Future Stationary Power Energy Conversion Efficiency Solar Energy Wind Energy Water Power Supercritical CO2 Geothermal Natural Gas Safety, Security & Resilience of the Energy Infrastructure Energy Storage Nuclear Power & Engineering Grid Modernization Battery Testing Nuclear Fuel Cycle Defense

  11. Technical Reference for Hydrogen Compatibility of Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    15/2008 Technical Reference on Hydrogen Compatibility of Materials Austenitc Steels: 300-Series Stainless Alloys Stabilized Alloys, Types 321 and 347 (code 2104) Prepared by: B.P. Somerday, Sandia National Laboratories, Livermore CA Editors C. San Marchi B.P. Somerday Sandia National Laboratories This report may be updated and revised periodically in response to the needs of the technical community; up-to-date versions can be requested from the editors at the address given below or downloaded at

  12. Technical Reference on Hydrogen Compatibility of Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Type 316 (code 2103) Prepared by: C. San Marchi, Sandia National Laboratories Editors C. San Marchi B.P. Somerday Sandia National Laboratories This report may be updated and revised periodically in response to the needs of the technical community; up-to-date versions can be requested from the editors at the address given below. The success of this reference depends upon feedback from the technical community; please forward your comments, suggestions, criticisms and relevant public- domain data

  13. Technical Reference on Hydrogen Compatibility of Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    321 Unlimited Release Printed September 2012 Technical Reference for Hydrogen Compatibility of Materials C. San Marchi B.P. Somerday Prepared by Sandia National Laboratories Albuquerque, New Mexico 87185 and Livermore, California 94550 Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract

  14. The Hydrogen Laboratory and The Brazilian Reference Center for...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    The Hydrogen Laboratory and The Brazilian Reference Center for Hydrogen Energy The Hydrogen Laboratory and The Brazilian Reference Center for Hydrogen Energy Presentation given by ...

  15. NPS Reference Manual 53: Special Park Uses | Open Energy Information

    Open Energy Info (EERE)

    search OpenEI Reference LibraryAdd to library PermittingRegulatory Guidance - Inner-Office Memorandum: NPS Reference Manual 53: Special Park UsesPermittingRegulatory...

  16. Biomass Scenario Model Documentation: Data and References Lin...

    Office of Scientific and Technical Information (OSTI)

    Documentation: Data and References Lin, Y.; Newes, E.; Bush, B.; Peterson, S.; Stright, D. 09 BIOMASS FUELS BIOMASS SCENARIO MODEL; BSM; BIOMASS; BIOFUEL; MODEL; DATA; REFERENCES;...

  17. Terms of Reference for the International Partnership for the...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Terms of Reference for the International Partnership for the Hydrogen Economy Terms of Reference for the International Partnership for the Hydrogen Economy Updated version (October ...

  18. Detailed HCCI Exhaust Speciation - ORNL Reference Fuel Blends...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    HCCI Exhaust Speciation - ORNL Reference Fuel Blends Detailed HCCI Exhaust Speciation - ORNL Reference Fuel Blends *Accurately measure exhaust profile from an HCCI engine with a ...

  19. Archive Reference Buildings by Climate Zone: 3A Atlanta, Georgia...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications Archive Reference Buildings by Climate Zone: 3B Los Angeles, California Archive Reference Buildings by Climate Zone: 3B Las Vegas, Nevada Archive ...

  20. Plutonium Certified Reference Materials Price List | U.S. DOE...

    Office of Science (SC) Website

    NBL Program Office Home About Programs Certified Reference Materials (CRMs) Prices and ... Prices and Certificates Plutonium Certified Reference Materials Price List Print Text ...

  1. Renewable Energy Economic and Financial Analysis Terms of Reference...

    Open Energy Info (EERE)

    Analysis Terms of Reference Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Renewable Energy Economic and Financial Analysis Terms of Reference AgencyCompany...

  2. Renewable Energy Pipeline Development Terms of Reference | Open...

    Open Energy Info (EERE)

    Development Terms of Reference Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Renewable Energy Pipeline Development Terms of Reference AgencyCompany Organization:...

  3. Renewable Energy Business Development Terms of Reference | Open...

    Open Energy Info (EERE)

    Development Terms of Reference Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Renewable Energy Business Development Terms of Reference AgencyCompany Organization:...

  4. United States Department of the Interior - RM-53 - Reference...

    Open Energy Info (EERE)

    OpenEI Reference LibraryAdd to library PermittingRegulatory Guidance - GuideHandbook: United States Department of the Interior - RM-53 - Reference Manual - Special Park...

  5. INFLUENCE OF TEMPERATURE ON THE CORROSION POTENTIAL OF THE 241-AN-102 MULTI PROBE CORROSION MONITORING SYSTEM SECONDARY REFERENCE ELECTRODES

    SciTech Connect (OSTI)

    EDGEMON GL; TAYLOR TM

    2008-09-30

    A test program using 241-AN-102 waste simulants and metallic secondary reference electrodes similar to those used on the 241-AN-102 MPCMS was performed to characterize the relationship between temperature and secondary reference electrode open-circuit corrosion potential. This program showed that the secondary reference electrodes can be used to make tank and tank steel corrosion potential measurements, but that a correction factor of approximately 2 mV per degree Celsius of temperature difference must be applied, where temperature difference is defined as the difference between tank temperature at the time of measurement and 30 C, the average tank temperature during the first several months of 241-AN-102 MPCMS operation (when the corrosion potentials of the secondary reference electrodes were being recorded relative to the primary reference electrodes).

  6. Nuclear Science References (NSR) from the National Nuclear Data Center (NNDC)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    The Nuclear Science References (NSR) database is an indexed bibiliography of primary and secondary references in nuclear physics research. About 80 journals are regularly scanned for articles. Recent references are added on a weekly basis. Approximately 4300 entries are added to the database annually. In general, articles are included in NSR if they include measured, calculated, or deduced quantitative nuclear structure or reaction data. Papers that apply previously known data are generally not included. Examples of this include neutron activation analysis using known cross sections or radiological dating using known half-lives. The database can be searched like a normal bibliographic database but can also be searched by the data that distinguishes it, data such as the nuclide, target/parent/daughter, reaction, incident particles, and outgoing particles. (Specialized Interface) [Taken from the NSR Help pages at http://www.nndc.bnl.gov/nsr/nsr_help.jsp

  7. Primary & Secondary Navigation Menus (help/navigation)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Power Services Site Navigation Aids Primary & Secondary Navigation Menus The primary navigation menus are located in the black horizontal navigation bars at the top and bottom of...

  8. Primary Energy Ventures | Open Energy Information

    Open Energy Info (EERE)

    Energy Ventures Jump to: navigation, search Name: Primary Energy Ventures Place: Oak Brook, Illinois Zip: 60523 Product: Primary Energy Ventures is a privately held developer,...

  9. Lead-free primary explosives

    DOE Patents [OSTI]

    Huynh, My Hang V.

    2010-06-22

    Lead-free primary explosives of the formula (cat).sub.Y[M.sup.II(T).sub.X(H.sub.2O).sub.6-X].sub.Z, where T is 5-nitrotetrazolate, and syntheses thereof are described. Substantially stoichiometric equivalents of the reactants lead to high yields of pure compositions thereby avoiding dangerous purification steps.

  10. 2014 Manufacturing Energy and Carbon Footprints: References

    Energy Savers [EERE]

    References 21 st Century Truck Partnership. 2013. Roadmap and Technical White Papers. http://www1.eere.energy.gov/vehiclesandfuels/pdfs/program/21ctp_roadmap_white_papers_2013.pdf ACEEE (American Council for an Energy-Efficient Economy). 2012. "Water Heating." http://aceee.org/consumer/water-heating Actel. 2009. Motor Efficiency Depends Upon Power Factor. http://www.actel.com/documents/Motor_PowerFactor_WP.pdf Ahmed, Ludna. 2011. Chlor-Alkali Industries: Caustic soda, Chlorine, Soda

  11. Department of Energy Construction Safety Reference Guide

    SciTech Connect (OSTI)

    Not Available

    1993-09-01

    DOE has adopted the Occupational Safety and Health Administration (OSHA) regulations Title 29 Code of Federal Regulations (CFR) 1926 ``Safety and Health Regulations for Construction,`` and related parts of 29 CFR 1910, ``Occupational Safety and Health Standards.`` This nonmandatory reference guide is based on these OSHA regulations and, where appropriate, incorporates additional standards, codes, directives, and work practices that are recognized and accepted by DOE and the construction industry. It covers excavation, scaffolding, electricity, fire, signs/barricades, cranes/hoists/conveyors, hand and power tools, concrete/masonry, stairways/ladders, welding/cutting, motor vehicles/mechanical equipment, demolition, materials, blasting, steel erection, etc.

  12. Coal Data: A reference. [Contains Glossary

    SciTech Connect (OSTI)

    Not Available

    1991-11-26

    The purpose of Coal Data: A Reference is to provide basic information on the mining and use of coal, an important source of energy in the United States. The report is written for a general audience. The goal is to cover basic material and strike a reasonable compromise between overly generalized statements and detailed analyses. The section Coal Terminology and Related Information'' provides additional information about terms mentioned in the text and introduces new terms. Topics covered are US coal deposits, resources and reserves, mining, production, employment and productivity, health and safety, preparation, transportation, supply and stocks, use, coal, the environment, and more. (VC)

  13. Manufacturing Energy and Carbon Footprint References | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    References Manufacturing Energy and Carbon Footprint References PDF icon footprint_references.pdf More Documents & Publications 2010 Manufacturing Energy and Carbon Footprints: References 2010 Manufacturing Energy and Carbon Footprints: Definitions and Assumptions Webtrends Archives by Fiscal Year - Advanced Manufacturing Office

  14. FAQS Reference Guide - Aviation Manager | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Manager FAQS Reference Guide - Aviation Manager This reference guide addresses the competency statements in the January 2010 edition of DOE-STD-1164-2003 Chg 1, Aviation Safety Officer Functional Area Qualification Standard. PDF icon Aviation Manager Qualification Standard Reference Guide, March 2010 More Documents & Publications FAQS Reference Guide - Aviation Safety Officer Inspection Report: IG-0654 DOE-STD-1165

  15. Excepted Service EJ and EK Desk Reference | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Excepted Service EJ and EK Desk Reference Excepted Service EJ and EK Desk Reference The Excepted Service EJ and EK Desk Reference is designed to provide the framework, in conjunction, with the DOE O 329.1 (Excepted Service Authorities for EJ and EK Pay Plans). Specifically, the desk reference addresses the requirements for the Excepted Service EJ and EK positions. PDF icon Excepted Service EJ and EK Desk Reference Responsible Contacts Antoinette Moultrie HUMAN RESOURCES SPECIALIST E-mail

  16. 2010 Manufacturing Energy and Carbon Footprints: References | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy References 2010 Manufacturing Energy and Carbon Footprints: References This five-page document provides the references to the Manufacturing Energy and Carbon Footprints (MECS 2010) PDF icon References for the Manufacturing Energy and Carbon Footprints (MECS 2010) More Documents & Publications Manufacturing Energy and Carbon Footprint References 2010 Manufacturing Energy and Carbon Footprints: Definitions and Assumptions Webtrends Archives by Fiscal Year - Advanced Manufacturing

  17. Generic Argillite/Shale Disposal Reference Case

    SciTech Connect (OSTI)

    Zheng, Liange; Colon, Carlos Jové; Bianchi, Marco; Birkholzer, Jens

    2014-08-08

    Radioactive waste disposal in a deep subsurface repository hosted in clay/shale/argillite is a subject of widespread interest given the desirable isolation properties, geochemically reduced conditions, and widespread geologic occurrence of this rock type (Hansen 2010; Bianchi et al. 2013). Bianchi et al. (2013) provides a description of diffusion in a clay-hosted repository based on single-phase flow and full saturation using parametric data from documented studies in Europe (e.g., ANDRA 2005). The predominance of diffusive transport and sorption phenomena in this clay media are key attributes to impede radionuclide mobility making clay rock formations target sites for disposal of high-level radioactive waste. The reports by Hansen et al. (2010) and those from numerous studies in clay-hosted underground research laboratories (URLs) in Belgium, France and Switzerland outline the extensive scientific knowledge obtained to assess long-term clay/shale/argillite repository isolation performance of nuclear waste. In the past several years under the UFDC, various kinds of models have been developed for argillite repository to demonstrate the model capability, understand the spatial and temporal alteration of the repository, and evaluate different scenarios. These models include the coupled Thermal-Hydrological-Mechanical (THM) and Thermal-Hydrological-Mechanical-Chemical (THMC) models (e.g. Liu et al. 2013; Rutqvist et al. 2014a, Zheng et al. 2014a) that focus on THMC processes in the Engineered Barrier System (EBS) bentonite and argillite host hock, the large scale hydrogeologic model (Bianchi et al. 2014) that investigates the hydraulic connection between an emplacement drift and surrounding hydrogeological units, and Disposal Systems Evaluation Framework (DSEF) models (Greenberg et al. 2013) that evaluate thermal evolution in the host rock approximated as a thermal conduction process to facilitate the analysis of design options. However, the assumptions and the properties (parameters) used in these models are different, which not only make inter-model comparisons difficult, but also compromise the applicability of the lessons learned from one model to another model. The establishment of a reference case would therefore be helpful to set up a baseline for model development. A generic salt repository reference case was developed in Freeze et al. (2013) and the generic argillite repository reference case is presented in this report. The definition of a reference case requires the characterization of the waste inventory, waste form, waste package, repository layout, EBS backfill, host rock, and biosphere. This report mainly documents the processes in EBS bentonite and host rock that are potentially important for performance assessment and properties that are needed to describe these processes, with brief description other components such as waste inventory, waste form, waste package, repository layout, aquifer, and biosphere. A thorough description of the generic argillite repository reference case will be given in Jové Colon et al. (2014).

  18. Semantic Features for Classifying Referring Search Terms

    SciTech Connect (OSTI)

    May, Chandler J.; Henry, Michael J.; McGrath, Liam R.; Bell, Eric B.; Marshall, Eric J.; Gregory, Michelle L.

    2012-05-11

    When an internet user clicks on a result in a search engine, a request is submitted to the destination web server that includes a referrer field containing the search terms given by the user. Using this information, website owners can analyze the search terms leading to their websites to better understand their visitors needs. This work explores some of the features that can be used for classification-based analysis of such referring search terms. We present initial results for the example task of classifying HTTP requests countries of origin. A system that can accurately predict the country of origin from query text may be a valuable complement to IP lookup methods which are susceptible to the obfuscation of dereferrers or proxies. We suggest that the addition of semantic features improves classifier performance in this example application. We begin by looking at related work and presenting our approach. After describing initial experiments and results, we discuss paths forward for this work.

  19. WECC Variable Generation Planning Reference Book

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Du, Pengwei; Etingov, Pavel V.; Ma, Jian; Vyakaranam, Bharat

    2013-05-14

    This planning reference book is a document reflecting a Western Electricity Coordination Council (WECC) effort to put together multiple sources of information and provide a clear, systemic, comprehensive outline of the problems, both existing and anticipated; their impacts on the system; currently used and proposed solutions by the industry and research community; planning practices; new technologies, equipment, and standards; and expected future trends. This living (periodically updated) document could help WECC and other practicing engineers, especially the younger generation of engineers joining the workforce, to get familiar with a large variety of information related to the integration of variable resources into the WECC system, bypassing in part the need for time-consuming information gathering and learning processes from more experienced engineers or from the literature.

  20. ACAA fly ash basics: quick reference card

    SciTech Connect (OSTI)

    2006-07-01

    Fly ash is a fine powdery material created when coal is burned to generate electricity. Before escaping into the environment via the utility stacks, the ash is collected and may be stored for beneficial uses or disposed of, if necessary. The use of fly ash provides environmental benefits, such as the conservation of natural resources, the reduction of greenhouse gas emissions and eliminating the needed for ash disposal in landfills. It is also a valuable mineral resource that is used in construction and manufacturing. Fly ash is used in the production of Portland cement, concrete, mortars and stuccos, manufactured aggregates along with various agricultural applications. As mineral filler, fly ash can be used for paints, shingles, carpet backing, plastics, metal castings and other purposes. This quick reference card is intended to provide the reader basic source, identification and composition, information specifically related to fly ash.

  1. CRYSTALLINE CERAMIC WASTE FORMS: REFERENCE FORMULATION REPORT

    SciTech Connect (OSTI)

    Brinkman, K.; Fox, K.; Marra, J.

    2012-05-15

    The research conducted in this work package is aimed at taking advantage of the long term thermodynamic stability of crystalline ceramics to create more durable waste forms (as compared to high level waste glass) in order to reduce the reliance on engineered and natural barrier systems. Durable ceramic waste forms that incorporate a wide range of radionuclides have the potential to broaden the available disposal options and to lower the storage and disposal costs associated with advanced fuel cycles. Assemblages of several titanate phases have been successfully demonstrated to incorporate radioactive waste elements, and the multiphase nature of these materials allows them to accommodate variation in the waste composition. Recent work has shown that they can be successfully produced from a melting and crystallization process. The objective of this report is to explain the design of ceramic host systems culminating in a reference ceramic formulation for use in subsequent studies on process optimization and melt property data assessment in support of FY13 melter demonstration testing. The waste stream used as the basis for the development and testing is a combination of the projected Cs/Sr separated stream, the Trivalent Actinide - Lanthanide Separation by Phosphorous reagent Extraction from Aqueous Komplexes (TALSPEAK) waste stream consisting of lanthanide fission products, the transition metal fission product waste stream resulting from the transuranic extraction (TRUEX) process, and a high molybdenum concentration with relatively low noble metal concentrations. In addition to the combined CS/LN/TM High Mo waste stream, variants without Mo and without Mo and Zr were also evaluated. Based on the results of fabricating and characterizing several simulated ceramic waste forms, two reference ceramic waste form compositions are recommended in this report. The first composition targets the CS/LN/TM combined waste stream with and without Mo. The second composition targets with CS/LN/TM combined waste stream with Mo and Zr removed. Waste streams that contain Mo must be produced in reducing environments to avoid Cs-Mo oxide phase formation. Waste streams without Mo have the ability to be melt processed in air. A path forward for further optimizing the processing steps needed to form the targeted phase assemblages is outlined in this report. Processing modifications including melting in a reducing atmosphere, and controlled heat treatment schedules are anticipated to improve the targeted elemental partitioning.

  2. H2FIRST Reference Station Design Task: Project Deliverable 2...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Reference Station Design Task: Project Deliverable 2-2 H2FIRST Reference Station Design Task: Project Deliverable 2-2 This H2FIRST project report, published in April 2015, presents ...

  3. Reference Manual and Procedures for Implementation of PURPA Standards...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    EPACT 2005 (March 2006) Reference Manual and Procedures for Implementation of PURPA Standards in EPACT 2005 (March 2006) This reference manual is intended to be used as an aid to state ...

  4. Biomass Scenario Model Documentation: Data and References

    SciTech Connect (OSTI)

    Lin, Y.; Newes, E.; Bush, B.; Peterson, S.; Stright, D.

    2013-05-01

    The Biomass Scenario Model (BSM) is a system dynamics model that represents the entire biomass-to-biofuels supply chain, from feedstock to fuel use. The BSM is a complex model that has been used for extensive analyses; the model and its results can be better understood if input data used for initialization and calibration are well-characterized. It has been carefully validated and calibrated against the available data, with data gaps filled in using expert opinion and internally consistent assumed values. Most of the main data sources that feed into the model are recognized as baseline values by the industry. This report documents data sources and references in Version 2 of the BSM (BSM2), which only contains the ethanol pathway, although subsequent versions of the BSM contain multiple conversion pathways. The BSM2 contains over 12,000 total input values, with 506 distinct variables. Many of the variables are opportunities for the user to define scenarios, while others are simply used to initialize a stock, such as the initial number of biorefineries. However, around 35% of the distinct variables are defined by external sources, such as models or reports. The focus of this report is to provide insight into which sources are most influential in each area of the supply chain.

  5. WECC Variable Generation Planning Reference Book: Appendices

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Du, Pengwei; Etingov, Pavel V.; Ma, Jian; Vyakaranam, Bharat

    2013-05-13

    The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

  6. One in five online scholarly articles affected by 'reference rot'

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    One in five online scholarly articles affected by 'reference rot' Alumni Link: Opportunities, News and Resources for Former Employees Latest Issue:September 2015 all issues All Issues » submit One in five online scholarly articles affected by 'reference rot' Los Alamos authors focus on reference rot, the combination of link rot and content drift to which references to web resources included in STM articles are subject. March 1, 2015 From left, Los Alamos National Laboratory authors Lyudmila

  7. FAQS Reference Guide - Aviation Safety Officer | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Safety Officer FAQS Reference Guide - Aviation Safety Officer This reference guide addresses the competency statements in the January 2010 edition of DOE-STD-1164-2003 Chg 1, Aviation Safety Officer Functional Area Qualification Standard. PDF icon Aviation Safety Officer Qualification Standard Reference Guide, March 2010 More Documents & Publications FAQS Reference Guide - Aviation Manager DOE-STD-1165-2003 DOE-STD-1164

  8. One in five online scholarly articles affected by 'reference rot'

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Scholarly articles affected by 'reference rot' One in five online scholarly articles affected by 'reference rot' Los Alamos authors focus on reference rot, the combination of link rot and content drift to which references to web resources included in STM articles are subject. January 26, 2015 From left, Los Alamos National Laboratory authors Lyudmila Balakireva, Herbert Van De Sompel and Harihar Shankar, and Martin Klein and Robert Sanderson (on computer screens). Their work was published in the

  9. FAQS Reference Guide - Waste Management | Department of Energy

    Energy Savers [EERE]

    Waste Management FAQS Reference Guide - Waste Management This reference guide addresses the competency statements in the January 2003 edition of DOE-STD-1159-2003, Waste Management Functional Area Qualification Standard. PDF icon Waste Management Qualification Standard Reference Guide, August 2010 More Documents & Publications FAQS Reference Guide - Environmental Restoration DOE-HDBK-1018/1-93 DOE-HDBK-1018/2-93

  10. Comprehensive aerological reference data set (CARDS)

    SciTech Connect (OSTI)

    Eskridge, R.E.; Polansky, A.C.; Alduchov, O.A.

    1997-11-01

    The possibility of anthropogenic climate change has reached the attention of Government officials and researchers. However, one cannot study climate change without climate data. The CARDS project will produce high-quality upper-air data for the research community and for policy-makers. The authors intend to produce a dataset which is: easy to use, as complete as possible, as free of random errors as possible. They will also attempt to identify biases and remove them whenever possible. In this report, they relate progress toward their goal. They created a robust new format for archiving upper-air data, and designed a relational database structure to hold them. The authors have converted 13 datasets to the new format and have archived over 10,000,000 individual soundings from 10 separate data sources. They produce and archive a metadata summary of each sounding they load. They have researched station histories, and have built a preliminary upper-air station history database. They have converted station-sorted data from their primary database into synoptic-sorted data in a parallel database. They have tested and will soon implement an advanced quality-control procedure, capable of detecting and often repairing errors in geopotential height, temperature, humidity, and wind. This unique quality-control method uses simultaneous vertical, horizontal, and temporal checks of several meteorological variables. It can detect errors other methods cannot.

  11. Microsoft Word - Cross Reference Matrix Introduction.doc | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Cross Reference Matrix Introduction.doc Microsoft Word - Cross Reference Matrix Introduction.doc PDF icon Microsoft Word - Cross Reference Matrix Introduction.doc More Documents & Publications Quality Assurance Requirements USA RS Basic Contract - Contract No.: DE-RW0000005 Office of Civilian Radioactive Waste Management-Quality Assurance Requirements and Description

  12. The production and certification of a plutonium equal-atom reference material: NBL CRM 128

    SciTech Connect (OSTI)

    Crawford, D.W. . Office of Safeguards and Security); Gradle, C.G.; Soriano, M.D. )

    1990-07-01

    This report describes the design, production, and certification of the New Brunswick Laboratory plutonium equal-atom certified reference material (CRM), NBL CRM 128. The primary use of this CRM is for the determination of bias corrections encountered in the operation of a mass spectrometer. This reference material is available to the US Department of Energy contractor-operated and government-operated laboratories, as well as to the international nuclear safeguards community. The absolute, or unbiased, certified value for the CRM's Pu-242/Pu-239 ratio is 1.00063 {plus minus} 0.00026 (95% confidence interval) as of October 1, 1984. This value was obtained through the quantitative blending of high-purity, chemically and isotopically characterized separated isotopes, as well as through intercomparisons of CRM samples with calibration mixtures using thermal ionization mass spectrometry. 32 tabs.

  13. Aquifer thermal energy storage reference manual: seasonal thermal energy storage program

    SciTech Connect (OSTI)

    Prater, L.S.

    1980-01-01

    This is the reference manual of the Seasonal Thermal Energy Storage (STES) Program, and is the primary document for the transfer of technical information of the STES Program. It has been issued in preliminary form and will be updated periodically to include more technical data and results of research. As the program progresses and new technical data become available, sections of the manual will be revised to incorporate these data. This primary document contains summaries of: the TRW, incorporated demonstration project at Behtel, Alaska, Dames and Moore demonstration project at Stony Brook, New York, and the University of Minnesota demonstration project at Minneapolis-St. Paul, Minnesota; the technical support programs including legal/institutional assessment; economic assessment; environmental assessment; field test facilities; a compendia of existing information; numerical simulation; and non-aquifer STES concepts. (LCL)

  14. International linear collider reference design report

    SciTech Connect (OSTI)

    Aarons, G.

    2007-06-22

    The International Linear Collider will give physicists a new cosmic doorway to explore energy regimes beyond the reach of today's accelerators. A proposed electron-positron collider, the ILC will complement the Large Hadron Collider, a proton-proton collider at the European Center for Nuclear Research (CERN) in Geneva, Switzerland, together unlocking some of the deepest mysteries in the universe. With LHC discoveries pointing the way, the ILC -- a true precision machine -- will provide the missing pieces of the puzzle. Consisting of two linear accelerators that face each other, the ILC will hurl some 10 billion electrons and their anti-particles, positrons, toward each other at nearly the speed of light. Superconducting accelerator cavities operating at temperatures near absolute zero give the particles more and more energy until they smash in a blazing crossfire at the centre of the machine. Stretching approximately 35 kilometres in length, the beams collide 14,000 times every second at extremely high energies -- 500 billion-electron-volts (GeV). Each spectacular collision creates an array of new particles that could answer some of the most fundamental questions of all time. The current baseline design allows for an upgrade to a 50-kilometre, 1 trillion-electron-volt (TeV) machine during the second stage of the project. This reference design provides the first detailed technical snapshot of the proposed future electron-positron collider, defining in detail the technical parameters and components that make up each section of the 31-kilometer long accelerator. The report will guide the development of the worldwide R&D program, motivate international industrial studies and serve as the basis for the final engineering design needed to make an official project proposal later this decade.

  15. Jobs | U.S. DOE Office of Science (SC)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Jobs New Brunswick Laboratory (NBL) NBL Home About Organization Chart .pdf file (269KB) Points of Contact (POCs) History Directions Jobs Programs Certified Reference Materials ...

  16. Safety Data Sheets (SDS) for New Brunswick Laboratory Certified Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Materials (CRM) | U.S. DOE Office of Science (SC) Safety Data Sheets (SDS) for New Brunswick Laboratory Certified Reference Materials (CRM) New Brunswick Laboratory (NBL) NBL Home About Programs Certified Reference Materials (CRMs) Training NEPA Documents News Safety Data Sheets (SDS) for New Brunswick Laboratory Certified Reference Materials (CRM) Contact Information New Brunswick Laboratory U.S. Department of Energy Building 350 9800 South Cass Avenue Argonne, IL 60439-4899 P: (630)

  17. Existing Commercial Reference Buildings Constructed In or After 1980 |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy In or After 1980 Existing Commercial Reference Buildings Constructed In or After 1980 The files on this page contain commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. These U.S. Department of Energy (DOE) reference buildings are complete descriptions for whole building energy analysis. You can also return to a summary of building types and climate zones and information about other building

  18. Operational Plan and Desktop Reference for the Disability Employment

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Program | Department of Energy Operational Plan and Desktop Reference for the Disability Employment Program Operational Plan and Desktop Reference for the Disability Employment Program The Department of Energy's Plan and Desktop Reference for hiring individuals with disabilities. PDF icon Final-SOP-Disability-Employment-FY14.pdf Responsible Contacts Donna Friend HUMAN RESOURCES SPECIALIST E-mail donna.friend@hq.doe.dov Phone 202-586-5880 More Documents & Publications Operational Plan and

  19. FAQS Reference Guide - Quality Assurance | Department of Energy

    Energy Savers [EERE]

    Quality Assurance FAQS Reference Guide - Quality Assurance This reference guide has been developed to address the competency statements in the April 2002 edition of DOE-Standard (STD)-1150-2002, Quality Assurance Functional Area Qualification Standard. PDF icon Quality Assurance Qualification Standard Reference Guide, July 2012 More Documents & Publications Order Module--DOE O 414.1D, QUALITY ASSURANCE DOE Order on Quality Assurance SOPP-43, EM-23 Quality Assurance Oversight

  20. FAQS Reference Guide - Senior Technical Safety Manager | Department of

    Energy Savers [EERE]

    Energy Senior Technical Safety Manager FAQS Reference Guide - Senior Technical Safety Manager This reference guide has been developed to address the competency statements in the March 2013 edition of DOE-Standard (STD)-1175-2013, Senior Technical Safety Manager Functional Area Qualification Standard. PDF icon Senior Technical Safety Manager Qualification Standard Reference Guide, October 2013 More Documents & Publications FAQS Gap Analysis Qualification Card - Senior Technical Safety

  1. FAQS Reference Guide - Technical Program Manager | Department of Energy

    Energy Savers [EERE]

    Program Manager FAQS Reference Guide - Technical Program Manager This reference guide addresses the competency statements in the February 2004 edition of DOE-Standard (STD)-1178-2004, Technical Program Manager Functional Area Qualification Standard. PDF icon Technical Program Manager Qualification Standard Reference Guide, May 2013 More Documents & Publications DOE-STD-1104-2014 Training Site Visit Report, Lawrence Livermore National Laboratory - February 2011 Crosswalk of DOE-STD-1104 Bases

  2. FAQS Reference Guide - Weapon Quality Assurance | Department of Energy

    Energy Savers [EERE]

    Weapon Quality Assurance FAQS Reference Guide - Weapon Quality Assurance This reference guide addresses the competency statements in the August 2008 edition of DOE-STD-1025-2008, Weapon Quality Assurance Functional Area Qualification Standard. PDF icon Weapon Quality Assurance Qualification Standard Reference Guide, August 2009 More Documents & Publications FAQS Qualification Card - Weapon Quality Assurance DOE-STD-1025-2008 FAQS Job Task Analyses - Weapons Quality Assurance

  3. Headquarters Security Quick Reference Book | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Security Quick Reference Book Headquarters Security Quick Reference Book June 2013 This quick reference book provides an overview of Department of Energy (DOE) Headquarters (HQ) security programs. It is not meant to replace the DOE Headquarters Facilities Master Security Plan (HQFMSP), which provides detailed instructions for the implementation of DOE safeguards and security requirements as published in a number of DOE orders, policies, notices, and guides. This book is a tool that can be used

  4. Trends in Commercial Buildings--Total Primary Energy Detail

    U.S. Energy Information Administration (EIA) Indexed Site

    Energy Consumption and Graph Total Primary Energy Consumption Graph Detail and Data Table 1979 to 1992 primary consumption trend with 95% confidence ranges 1979 to 1992 primary...

  5. Designing Renewable Energy Financing Mechanism Terms of Reference...

    Open Energy Info (EERE)

    Designing Renewable Energy Financing Mechanism Terms of Reference (Redirected from Designing Renewable Energy Financing Mechanisms) Jump to: navigation, search Tool Summary LAUNCH...

  6. FAQS Reference Guide – Electrical Systems and Safety Oversight

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the August 2007 edition of DOE-STD-1170-2007, Electrical Systems and Safety Oversight Functional Area Qualification Standard.

  7. Annual Energy Outlook 2013 Early Release Reference Case

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    emission intensity index, 20051 Source: EIA, Annual Energy Outlook 2015 Reference case History Projections 2013 Carbon dioxide emissions per 2009 dollar GDP Energy use per 2009...

  8. FAQS Reference Guide – NNSA Package Certification Engineer

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the February 2009 edition of DOE-STD-1026-2009, NNSA Package Certification Engineer Functional Area Qualification Standard.

  9. Designing Renewable Energy Financing Mechanism Terms of Reference...

    Open Energy Info (EERE)

    Support Design of Institutional and Financial Intermediation Scheme for a Micro hydro Power Development Program Design of a Rural Energy Fund References "Designing...

  10. EERE Postdoctoral Research Award Letter of Reference Form

    Broader source: Energy.gov [DOE]

    EERE Postdoctoral Research Award Letter of Reference Form, from the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy.

  11. 2008 Annual Merit Review Results Summary - 18. Cross-Reference...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications 2010 Annual Merit Review Results Cross Reference of PIs and Organizations DOE Vehicle Technologies Program 2009 Merit Review Report - PI and Project ...

  12. FAQS Reference Guide – Safeguards and Security General Technical Base

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the July 2009 edition of DOE-STD-1123-2009, Safeguards and Security General Technical Base Qualification Standard.

  13. FAQS Reference Guide – Transportation and Traffic Management

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the September 2002 edition of DOE-STD-1155-2002, Transportation and Traffic Functional Area Qualification Standard.

  14. A time-dependent formulation of multi-reference perturbation...

    Office of Scientific and Technical Information (OSTI)

    Title: A time-dependent formulation of multi-reference perturbation theory Authors: Sokolov, Alexander Yu. 1 ; Chan, Garnet Kin-Lic 1 + Show Author Affiliations Department of ...

  15. Development of Compact Gaseous Sensors with Internal Reference...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for Monitoring O2 and NOx in Combustion Environments Development of Compact Gaseous Sensors with Internal Reference for Monitoring O2 and NOx in Combustion Environments ...

  16. Renewable Energy Cross Sectoral Assessments Terms of Reference...

    Open Energy Info (EERE)

    Renewable Energy Cross Sectoral Assessments Terms of Reference Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Renewable Energy Cross Sectoral Assessments Terms of...

  17. Renewable Energy Terms of Reference: Laws, Policies and Regulations...

    Open Energy Info (EERE)

    Laws, Policies and Regulations Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Renewable Energy Terms of Reference: Laws, Policies and Regulations AgencyCompany...

  18. Reference Model for Control and Automation Systems in Electrical...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Model for Control and Automation Systems in Electrical Power (October 2005) Reference Model for Control and Automation Systems in Electrical Power (October 2005) Modern ...

  19. Sandia Energy - DOE-Sponsored Reference Model Project Results...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    partnered effort to develop marine hydrokinetic (MHK) reference models (RMs) for wave energy converters and tidal, ocean, and river current energy converters. The RMP team...

  20. Practical Calculation of Molecular Acidity with the Aid of a Reference Molecule

    SciTech Connect (OSTI)

    Burger, Steven K; Liu, Shubin; Ayers, Paul W

    2011-02-24

    A set of linear free energy models are presented for determining the pK{sub a} values of amines, alcohols, and carboxylic acids. Models are determined from a series of pK{sub a} predictors, taken both from traditional natural atomic orbital analysis (NAO) and from a novel approach introduced here of using a reference molecule: an ammonium ion for amines and a hydrogen sulfide molecule for alcohols and carboxylic acids. Using these reference molecules, we calculate the barrier to proton transfer and show that a number of properties associated with the transition state are correlated with the pK{sub a}. By considering 38 predictors, we obtain a four-variable model for amines and a three-variable model for oxygen-containing compounds. The model for amines is based on 145 compounds and has a root mean squared error (RMSE) of 0.45 and R{sup 2} = 0.98. The oxygen set has 48 molecules: RMSE = 0.26, and R{sup 2} = 0.993. Similar, linear, and multilinear models are constructed after separating the sets into chemically similar categories: alcohols, carboxylic acids, and primary, secondary, tertiary, and aromatic amines. This separation gives simpler models with relatively low RMSE values, where the most important predictor of the pK{sub a} is the difference in energy between transferring the proton from the reference molecular base to the conjugate acid from the data set.

  1. Archived Reference Climate Zone: 3A Atlanta, Georgia

    Office of Energy Efficiency and Renewable Energy (EERE)

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  2. Archived Reference Climate Zone: 3A Atlanta, Georgia

    Office of Energy Efficiency and Renewable Energy (EERE)

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  3. Archived Reference Climate Zone: 6A Minneapolis, Minnesota

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  4. Archived Reference Climate Zone: 6A Minneapolis, Minnesota

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  5. Archived Reference Climate Zone: TMY2 Weather Data

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  6. Archived Reference Climate Zone: TMY2 Weather Data

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  7. Functional Area Qualification Standard Reference Guides | Department of

    Energy Savers [EERE]

    Energy Reference Guides Functional Area Qualification Standard Reference Guides Aviation Manager Aviation Safety Officer Chemical Processing Civil/Structural Engineering Construction Management Criticality Safety Criticality Safety Support Group, NNSA SC Electrical Systems and Safety Oversight Emergency Management Environmental Compliance Environmental Restoration Facility Maintenance Management Facility Representative Fire Protection Engineering General Technical Base Industrial Hygiene

  8. Archived Reference Building Type: Stand-alone retail

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  9. Archived Reference Building Type: Stand-alone retail

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  10. Archived Reference Climate Zone: 3B Los Angeles, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  11. Archived Reference Climate Zone: 3B Los Angeles, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  12. Archived Reference Climate Zone: 1A Miami, Florida

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  13. Archived Reference Climate Zone: 1A Miami, Florida

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  14. Webinar October 13: Reference Designs for Hydrogen Fueling Stations

    Broader source: Energy.gov [DOE]

    The Fuel Cell Technologies Office will present a live webinar titled "Reference Designs for Hydrogen Fueling Stations" on Tuesday, October 13, from 12 to 1 p.m. Eastern Daylight Time (EDT). This presentation will discuss the process and findings of the work, recommended future research and development topics, and outline planned next steps for the H2FIRST Reference Station Design Task.

  15. Archived Reference Climate Zone: 4B Albuquerque, New Mexico

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Climate Zone: 4B Albuquerque, New Mexico

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  17. Archived Reference Climate Zone: 2B Phoenix, Arizona

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  18. Archived Reference Climate Zone: 2B Phoenix, Arizona

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  19. Archived Reference Climate Zone: 3C San Francisco, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  20. Archived Reference Climate Zone: 3C San Francisco, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  1. Archived Reference Climate Zone: 3B Las Vegas, Nevada

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  2. Archived Reference Climate Zone: 3B Las Vegas, Nevada

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  3. Archived Reference Climate Zone: 4A Baltimore, Maryland

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  4. Archived Reference Climate Zone: 4A Baltimore, Maryland

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  5. Archived Reference Climate Zone: 6B Helena, Montana

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  6. Archived Reference Climate Zone: 6B Helena, Montana

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  7. FAQS Reference Guide - Technical Training | Department of Energy

    Energy Savers [EERE]

    Training FAQS Reference Guide - Technical Training This reference guide addresses the competency statements in the February 2004 edition of DOE-STD-1179-2004, Technical Training Functional Area Qualification Standard. PDF icon Technical Training Qualification Standard Reference Guide, December 2009 More Documents & Publications DOE-HDBK-1206-98 DOE-HDBK-1001-96 Order Module--DOE-HDBK-1203-97, GUIDE TO GOOD PRACTICES FOR TRAINING OF TECHNICAL STAFF AND MANAGERS, DOE-HDBK-1204-97, GUIDE TO

  8. Oil, gas, and helium references index for the Navajo Indian Reservation, Arizona, New Mexico, and Utah. [223 references

    SciTech Connect (OSTI)

    Bliss, J.D.

    1982-02-01

    The references which are listed in this document represent the readily available literature about oil, gas, and helium resources on or adjacent to the Navajo Indian Reservation. They were selected during the developmental phase of the Navajo Resource Information System (NRIS). The system contains a set of computerized data bases addressing various resource categories. The system was developed by the US Geological Survey in coordination with the Minerals Department, Navajo Nation. Literature is the foundation of resource assessment and the absence of such a compilation for the Navajo Nation prompted the development of a reference data base entitled nref, which consists of over 1300 records. The following reference list of approximately 230 references was selected from those citations which contain oil, gas, or helium in a keyword list attached to each citation. References to general literature on oil, gas, or helium may also be present. The main attempt was to list most of the literature published in the 1960's and 1970's for areas in, or adjacent to, the Navajo Reservation. References published prior to this were included only if readily available or if they seemed to represent areas or topics not covered in later publications. 223 references.

  9. Webinar October 13: Reference Designs for Hydrogen Fueling Stations...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Eastern Daylight Time (EDT). The goal of the H2FIRST Reference Station Design Task is to accelerate acceptance of near-term hydrogen infrastructure build-out by exploring the ...

  10. Archive Reference Buildings by Building Type: Small office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  11. Archive Reference Buildings by Building Type: Stand-alone retail

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  12. Existing Commercial Reference Buildings Constructed Before 1980 — Archive

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary of building types and...

  13. Reference Linking at the DOE Office of Scientific and Technical...

    Office of Scientific and Technical Information (OSTI)

    Reference Linking at the DOE Office of Scientific and Technical Information The usefulness of electronic R&D reports, such as those accessed via the DOE Information Bridge, is ...

  14. Archive Reference Buildings by Building Type: Fast food

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  15. One in five online scholarly articles affected by 'reference...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    content drift to which references to web resources included in STM articles are subject. ... "For more than 70 percent of papers that link to web pages, revisiting the originally ...

  16. Archive Reference Buildings by Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  17. FAQS Reference Guide – Safety Software Quality Assurance

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the (March 2011) edition of DOE-STD-1172-2011, Safety Software Quality Assurance Functional Area Qualification Standard.

  18. Motivation for the Transaction-Based Reference Platform

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Motivation for the Transaction-Based Reference Platform Or How I learned to Stop Worrying and Love Transactions George Hernandez Pacific Northwest National Lab July 23-24, 2015 ...

  19. Desk Reference on DOE-Flex | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    PDF icon Desk Reference on DOE-Flex (July 2011) Responsible Contacts Bruce Murray HR Policy Advisor E-mail bruce.murray@hq.doe.gov Phone 202-586-3372 More Documents & Publications ...

  20. Archive Reference Buildings by Building Type: Strip mall

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  1. Biomass Scenario Model Documentation: Data and References (Technical

    Office of Scientific and Technical Information (OSTI)

    Report) | SciTech Connect Technical Report: Biomass Scenario Model Documentation: Data and References Citation Details In-Document Search Title: Biomass Scenario Model Documentation: Data and References The Biomass Scenario Model (BSM) is a system dynamics model that represents the entire biomass-to-biofuels supply chain, from feedstock to fuel use. The BSM is a complex model that has been used for extensive analyses; the model and its results can be better understood if input data used for

  2. Salton Sea Scientific Drilling Project Archival Reference, Final Draft

    SciTech Connect (OSTI)

    1991-03-13

    This report provides an archival reference to the scientific information and other pertinent documents and materials associated with the Salton Sea Scientific Drilling Project (SSDP). This archiving process ensures that valuable technical data and information obtained during the life of the project can be retrieved, organized and maintained as a historical record for future reference. This paper describes the background of the project and the process used for archiving the materials. [DJE-2005

  3. The Hydrogen Laboratory and The Brazilian Reference Center for Hydrogen

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy | Department of Energy The Hydrogen Laboratory and The Brazilian Reference Center for Hydrogen Energy The Hydrogen Laboratory and The Brazilian Reference Center for Hydrogen Energy Presentation given by Newton Pimenta and Cristiano Pinto of the State University of Campinas at the CNG and Hydrogen Lessons Learned Workshop on December 10, 2009 PDF icon cng_h2_workshop_12_ohi.pdf More Documents & Publications Overview of DOE - DOT December 2009 CNG and Hydrogen Fuels Workshop

  4. Manager's Desk Reference on Human Capital Management Flexibilities |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Manager's Desk Reference on Human Capital Management Flexibilities Manager's Desk Reference on Human Capital Management Flexibilities The purpose of this document is to provide DOE managers and supervisors with information on available flexibilities that can be used in day-to-day human capital management activities, especially those bearing on the recruitment and retention of high-quality staff. Each section of the document includes a basic description of a particular

  5. Microsoft Word - Cross Reference Matrix Introduction.doc

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cross Reference Matrix Introduction This cross-reference matrix is intended to provide NRC reviewers with an aid to show where Yucca Mountain Review Plan (YMRP) (NUREG-1804) acceptance criteria as well as 10 CFR Part 63 regulations are addressed within the Yucca Mountain Repository License Application. This matrix does not assert compliance with 10 CFR Part 63 or the YMRP; it is provided as an aid to reviewers. The information contained in this matrix is generally repeated in tables at the

  6. L.45 EXHIBIT E PAST PERFORMANCE REFERENCE INFORMATION FORM

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    L.45 EXHIBIT E PAST PERFORMANCE REFERENCE INFORMATION FORM 1. Complete name of Government agency, commercial firm, or other organization 2. Complete address 3. Contract number or other reference and type 4. Date of contract 5. Date work commenced 6. Date work was completed or scheduled to be completed 7. Contract Type and Contract Value 8. Final amount invoiced or amount invoiced to date 9a. Technical point of contact (name, title, company/agency, address, telephone number, fax number, and

  7. EERE Program Management Quick Reference Guide | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Quick Reference Guide EERE Program Management Quick Reference Guide Provides information on the EERE program management structure, program and project management roles/responsibilities, and sequence of activities in the program management cycle; also introduces EERE management concepts and tools. PDF icon pmquick_ref_guide.pdf More Documents & Publications EERE Program Management Guide - Chapter 2 EERE Program Management Guide - Chapter 4 EERE Program Management Guide - Chapter 5

  8. Operational Plan and Desktop Reference for the Veterans Employment Program

    Energy Savers [EERE]

    | Department of Energy Operational Plan and Desktop Reference for the Veterans Employment Program Operational Plan and Desktop Reference for the Veterans Employment Program DOE Guide to the President's Initiative for Veterans Employment. Includes: Department-wide policies and procedures, goals and objectives, DVAAP, information on veterans' preference and special hiring authorities, procedures for use of vocational rehabilitation programs, sources for finding veterans, and links to websites.

  9. Department of Energy's Hurricane Response Chronology, as Referred to by

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Secretary Bodman at Today's Senate Energy and Natural Resources Committee Hearing | Department of Energy Hurricane Response Chronology, as Referred to by Secretary Bodman at Today's Senate Energy and Natural Resources Committee Hearing Department of Energy's Hurricane Response Chronology, as Referred to by Secretary Bodman at Today's Senate Energy and Natural Resources Committee Hearing October 27, 2005 - 12:34pm Addthis Week 1: August 21 - 27, 2005 Katrina strikes south Florida 8/25 and

  10. Reference Manual and Procedures for Implementation of PURPA Standards in

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    EISA 2007 | Department of Energy EISA 2007 Reference Manual and Procedures for Implementation of PURPA Standards in EISA 2007 This reference manual is intended to be used as an aid to state commissions and utilities as they consider the new federal standards that are part of the Energy Independence and Security Act of 2007 (or EISA, sections 374, 531, 532, and 1307). It summarizes state commission and unregulated utility requirements, covers implementation procedures and issues to be

  11. Reference Manual and Procedures for Implementation of PURPA Standards in

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    EPACT 2005 (March 2006) | Department of Energy EPACT 2005 (March 2006) Reference Manual and Procedures for Implementation of PURPA Standards in EPACT 2005 (March 2006) This reference manual is intended to be used as an aid to state commissions and utilities as they consider the new federal standards that are part of the Energy Policy Act of 2005 (Subtitle E, "Amendments to PURPA," sections 1251, 1252, and 1254). It summarizes state commission and unregulated utility requirements

  12. Reference Links | U.S. DOE Office of Science (SC)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Links Integrated Support Center (ISC) ISC Home About Services Freedom of Information Act (FOIA) Privacy Act Advisory Exemptions How to Submit a FOIA Request Fee Waiver and Reduction Criteria Electronic Reading Room ISC Conventional Reading Rooms Reference Links Privacy Act NEPA Documents Contact Information Integrated Support Center Roxanne Purucker U.S. Department of Energy 9800 S. Cass Avenue Argonne, IL 60439 P: (630) 252-2110 Kenneth Tarcza U.S. Department of Energy 200

  13. Reference Links | U.S. DOE Office of Science (SC)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Links Integrated Support Center (ISC) ISC Home About Services Freedom of Information Act (FOIA) Privacy Act Compilation of Systems of Records Energy Employees Occupational Illness Compensation Program Act (EEOICPA) How to Submit a Privacy Act Request Reference Links NEPA Documents Contact Information Integrated Support Center Roxanne Purucker U.S. Department of Energy 9800 S. Cass Avenue Argonne, IL 60439 P: (630) 252-2110 Kenneth Tarcza U.S. Department of Energy 200 Administration

  14. Reference Model #1 - Tidal Energy: Resource Dr. Brian Polagye

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Model #1 - Tidal Energy: Resource Dr. Brian Polagye Northwest National Marine Renewable Energy Center University of Washington, Seattle, WA 1 Introduction Reference Model #1 is a tidal turbine operating in a narrow, tidal channel. The site is a generalized version of Tacoma Narrows, Puget Sound, Washington. The resource is a mixed, mainly semidiurnal tidal regime with two ebbs and floods each day of unequal strength (i.e., a diurnal inequality in which a strong ebb/flood exchange is

  15. Validation of reference materials for uranium radiochronometry in the frame

    Office of Scientific and Technical Information (OSTI)

    of nuclear forensic investigations (Journal Article) | DOE PAGES Published Article: Validation of reference materials for uranium radiochronometry in the frame of nuclear forensic investigations « Prev Next » Title: Validation of reference materials for uranium radiochronometry in the frame of nuclear forensic investigations Authors: Varga, Z. ; Mayer, K. ; Bonamici, C. E. ; Hubert, A. ; Hutcheon, I. ; Kinman, W. ; Kristo, M. ; Pointurier, F. ; Spencer, K. ; Stanley, F. ; Steiner, R. ;

  16. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    3, 3/11/13) Construction Subcontract Appendix SFA-1 Page 1 of 8 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: http://www.acquisition.gov/far/ or

  17. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    , 7/14/14) Appendix SFA-1 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at the following website addresses: * FAR: http://farsite.hill.af.mil/vffara.htm and * DEAR:

  18. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    , 7/14/14) Appendix SFA-1 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at the following website addresses: * FAR: http://farsite.hill.af.mil/vffara.htm and * DEAR:

  19. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    , 7/14/14) Appendix SFA-1 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at the following website addresses: * FAR: http://farsite.hill.af.mil/vffara.htm and * DEAR:

  20. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    , 7/14/14) Appendix SFA-1 Page 1 of 5 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website addresses: FAR: http://farsite.hill.af.mil/vffara.htm DEAR:

  1. REFERENCE CASES FOR USE IN THE CEMENTITOUS PARTNERSHIP PROJECT

    SciTech Connect (OSTI)

    Langton, C.; Kosson, D.; Garrabrants, A.

    2010-08-31

    The Cementitious Barriers Partnership Project (CBP) is a multi-disciplinary, multi-institution cross cutting collaborative effort supported by the US Department of Energy (DOE) to develop a reasonable and credible set of tools to improve understanding and prediction of the structural, hydraulic and chemical performance of cementitious barriers used in nuclear applications. The period of performance is >100 years for operating facilities and > 1000 years for waste management. The CBP has defined a set of reference cases to provide the following functions: (i) a common set of system configurations to illustrate the methods and tools developed by the CBP, (ii) a common basis for evaluating methodology for uncertainty characterization, (iii) a common set of cases to develop a complete set of parameter and changes in parameters as a function of time and changing conditions, (iv) a basis for experiments and model validation, and (v) a basis for improving conceptual models and reducing model uncertainties. These reference cases include the following two reference disposal units and a reference storage unit: (i) a cementitious low activity waste form in a reinforced concrete disposal vault, (ii) a concrete vault containing a steel high-level waste tank filled with grout (closed high-level waste tank), and (iii) a spent nuclear fuel basin during operation. Each case provides a different set of desired performance characteristics and interfaces between materials and with the environment. Examples of concretes, grout fills and a cementitious waste form are identified for the relevant reference case configurations.

  2. Working with SRNL - Our Facilities- Primary Standards Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Primary Standards Laboratory Working with SRNL Our Facilities - Primary Standards Laboratory The Primary Standards Laboratory at SRNL provides calibration services compliant to the requirements of the American national standard for calibration laboratories.

  3. The Reference Design for the ILC, Costs, and What's Next

    SciTech Connect (OSTI)

    Barish, Barry

    2007-03-26

    A Reference Design for the International Linear Collider was recently released. The scale of the ILC is such that it must be built by an international collaboration and the design is the culmination of a unique global effort. Through ICFA, a decision was made to base the design on superconducting RF technology and then the Global Design Effort (GDE) was created to coordinate the actual accelerator design toward a construction proposal. The reference design establishes all the features of the machine, and defines both the R&D program and engineering design that will now follow over the next few years.

  4. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    .1, 6/17/13) Appendix SFA-1 Page 1 of 6 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: http://www.acquisition.gov/far/ or http://www.management.energy.gov/DEAR.htm (c) The

  5. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    .1, 6/17/13) Appendix SFA-1 Page 1 of 6 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: http://www.acquisition.gov/far/ or http://www.management.energy.gov/DEAR.htm (c) The

  6. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2, 3/11/13) Appendix SFA-1 Page 1 of 9 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: http://www.acquisition.gov/far/ or http://www.management.energy.gov/DEAR.htm (c) The

  7. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SFA (Rev. 2, 3/11/13) Appendix SFA-1 Page 1 of 8 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: http://www.acquisition.gov/far/ or http://www.management.energy.gov/DEAR.htm

  8. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1, 3/11/13) Appendix SFA-1 Page 1 of 3 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: http://www.acquisition.gov/far/ or http://www.management.energy.gov/DEAR.htm (c) The

  9. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2, 3/11/13) Appendix SFA-1 Page 1 of 8 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: http://www.acquisition.gov/far/ or http://www.management.energy.gov/DEAR.htm (c) The

  10. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    , 3/11/13) Page 1 of 6 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: http://www.acquisition.gov/far/ or http://www.management.energy.gov/DEAR.htm (c) The following

  11. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    , 3/11/13) Appendix SFA-1 Page 1 of 6 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: http://www.acquisition.gov/far/ or http://www.management.energy.gov/DEAR.htm (c) The

  12. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    , 7/14/14) Appendix SFA-1 Page 1 of 7 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: FAR: http://farsite.hill.af.mil/vffara.htm DEAR: http://farsite.hill.af.mil/vfdoea.htm

  13. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    , 7/14/14) Appendix SFA-1 Page 1 of 8 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: FAR: http://farsite.hill.af.mil/vffara.htm DEAR: http://farsite.hill.af.mil/vfdoea.htm

  14. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    , 7/14/14) Appendix SFA-1 Page 1 of 8 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: FAR: http://farsite.hill.af.mil/vffara.htm DEAR: http://farsite.hill.af.mil/vfdoea.htm

  15. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2, 7/14/14) Appendix SFA-1 Page 1 of 3 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: FAR: http://farsite.hill.af.mil/vffara.htm DEAR: http://farsite.hill.af.mil/vfdoea.htm

  16. Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    , 7/14/14) Appendix SFA-1 Page 1 of 8 Appendix SFA-1 FAR & DEAR Clauses Incorporated By Reference (a) The Federal Acquisition Regulation (FAR) and the Department of Energy Acquisition Regulation (DEAR) clauses which are incorporated by reference herein shall have the same force and effect as if printed in full text. (b) Full text of the referenced clauses may be accessed electronically at website address: FAR: http://farsite.hill.af.mil/vffara.htm DEAR: http://farsite.hill.af.mil/vfdoea.htm

  17. Primary Characteristics of Loan Loss Reserve Funds | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Primary Characteristics of Loan Loss Reserve Funds Primary Characteristics of Loan Loss ... Typical residential energy efficiency loans, for example, are in the range of 5,000 to ...

  18. Organosilicon-Based Electrolytes for Long-Life Lithium Primary...

    Office of Scientific and Technical Information (OSTI)

    Long-Life Lithium Primary Batteries Citation Details In-Document Search Title: Organosilicon-Based Electrolytes for Long-Life Lithium Primary Batteries This report describes ...

  19. Primary Science of Energy Student Guide (42 Activities) | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Student Guide (42 Activities) Primary Science of Energy Student Guide (42 Activities) Information about Primary Science of Energy, 42 student activities on energy basics for grades...

  20. Preoperational test report, primary ventilation system

    SciTech Connect (OSTI)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Primary Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space filtered venting of tanks AY101, AY102, AZ101, AZ102. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  1. Analysis of standard reference materials by absolute INAA

    SciTech Connect (OSTI)

    Heft, R.E.; Koszykowski, R.F.

    1981-07-01

    Three standard reference materials, flyash, soil, and ASI 4340 steel, were analyzed by a method of absolute instrumental neutron activation analysis (INAA). Two different light water pool-type reactors were used to produce equivalent analytical results even though the epithermal to thermal flux ratio in one reactor was higher than that in the other by a factor of two.

  2. Reference design description for a geologic repository: Revision 01

    SciTech Connect (OSTI)

    1997-09-01

    This document describes the current design expectations for a potential geologic repository that could be located at Yucca Mountain in Nevada. This Reference Design Description (RDD) looks at the surface and subsurface repository and disposal container design. Additionally, it reviews the expected long-term performance of the potential repository. In accordance with current legislation, the reference design for the potential repository does not include an interim storage option. The reference design presented allows the disposal of highly radioactive material received from government-owned spent fuel custodian sites; produces high-level waste sites, and commercial spent fuel sites. All design elements meet current federal, state, and local regulations governing the disposal of high-level radioactive waste and protection of the public and the environment. Due to the complex nature of developing a repository, the design will be created in three phases to support Viability Assessment, License Application, and construction. This document presents the current reference design. It will be updated periodically as the design progresses. Some of the details presented here may change significantly as more cost-effective solutions, technical advancements, or changes to requirements are identified.

  3. Environmental Guidance Program Reference Book: American Indian Religious Freedom Act

    SciTech Connect (OSTI)

    Not Available

    1987-11-01

    This Reference Book contains a copy of the American Indian Religious Freedom Act and guidance for DOE compliance with the statute. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Updates that include important new requirements will be provided periodically.

  4. Primary coal crushers grow to meet demand

    SciTech Connect (OSTI)

    Fiscor, S.

    2009-09-15

    Mine operators look for more throughput with less fines generation in primary crushers (defined here as single role crushers and two stage crushers). The article gives advice on crusher selection and application. Some factors dictating selection include the desired product size, capacity, Hard Grove grindability index, percentage of rock to be freed and hardness of that rock. The hardness of coal probably has greatest impact on product fineness. 2 refs., 1 fig., 1 tab.

  5. JEDI Marine and Hydrokinetic Model: User Reference Guide

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    JCPOA NNSA Delivers Annual Reports to Congress on Progress for Stockpile Stewardship and Nuclear Nonproliferation WASHINGTON, D.C.-The Department of Energy's National Nuclear Security Administration (DOE/NNSA) today released the annual reports outlining the strategic direction for two of its vital and enduring missions-maintaining a safe, secure and effective nuclear deterrent and reducing the threat

    JEDI Marine and Hydrokinetic Model: User Reference Guide Marshall Goldberg MRG &

  6. Xyce Parallel Electronic Simulator : reference guide, version 4.1.

    SciTech Connect (OSTI)

    Mei, Ting; Rankin, Eric Lamont; Thornquist, Heidi K.; Santarelli, Keith R.; Fixel, Deborah A.; Coffey, Todd Stirling; Russo, Thomas V.; Schiek, Richard Louis; Keiter, Eric Richard; Pawlowski, Roger Patrick

    2009-02-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide.

  7. Reference Model 5 (RM5): Oscillating Surge Wave Energy Converter

    SciTech Connect (OSTI)

    Yu, Y. H.; Jenne, D. S.; Thresher, R.; Copping, A.; Geerlofs, S.; Hanna, L. A.

    2015-01-01

    This report is an addendum to SAND2013-9040: Methodology for Design and Economic Analysis of Marine Energy Conversion (MEC) Technologies. This report describes an Oscillating Water Column Wave Energy Converter (OSWEC) reference model design in a complementary manner to Reference Models 1-4 contained in the above report. A conceptual design for a taut moored oscillating surge wave energy converter was developed. The design had an annual electrical power of 108 kilowatts (kW), rated power of 360 kW, and intended deployment at water depths between 50 m and 100 m. The study includes structural analysis, power output estimation, a hydraulic power conversion chain system, and mooring designs. The results were used to estimate device capital cost and annual operation and maintenance costs. The device performance and costs were used for the economic analysis, following the methodology presented in SAND2013-9040 that included costs for designing, manufacturing, deploying, and operating commercial-scale MEC arrays up to 100 devices. The levelized cost of energy estimated for the Reference Model 5 OSWEC, presented in this report, was for a single device and arrays of 10, 50, and 100 units, and it enabled the economic analysis to account for cost reductions associated with economies of scale. The baseline commercial levelized cost of energy estimate for the Reference Model 5 device in an array comprised of 10 units is $1.44/kilowatt-hour (kWh), and the value drops to approximately $0.69/kWh for an array of 100 units.

  8. EFRC management reference document Energy Frontier Research Centers

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Acknowledgements Reference Document: The Office of Basic Energy Sciences (BES) requires funded principal investigators (PIs) to appropriately acknowledge BES support in publications and presentations based on BES-funded research. Such acknowledgements are used by BES for federally-mandated assessment and reporting functions. The practice of simply presenting a list of supporting agencies in a shared acknowledgement is not acceptable because it is impossible to discern the research BES funded

  9. Xyce parallel electronic simulator reference guide, version 6.0.

    SciTech Connect (OSTI)

    Keiter, Eric Richard; Mei, Ting; Russo, Thomas V.; Schiek, Richard Louis; Thornquist, Heidi K.; Verley, Jason C.; Fixel, Deborah A.; Coffey, Todd Stirling; Pawlowski, Roger Patrick; Warrender, Christina E.; Baur, David G.

    2013-08-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide [1].

  10. Reference Model for Control and Automation Systems in Electrical Power

    Energy Savers [EERE]

    Reference Model for Control and Automation Systems in Electrical Power Version 1.2 October 12, 2005 Prepared by: Sandia National Laboratories' Center for SCADA Security Jason Stamp, Technical Lead Michael Berg, Co-Technical Lead Michael Baca, Project Lead This work was conducted for the DOE Office of Electricity Delivery and Energy Reliability under Contract M64SCADSNL Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department

  11. Xyce parallel electronic simulator reference guide, version 6.1

    SciTech Connect (OSTI)

    Keiter, Eric R; Mei, Ting; Russo, Thomas V.; Schiek, Richard Louis; Sholander, Peter E.; Thornquist, Heidi K.; Verley, Jason C.; Baur, David Gregory

    2014-03-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide [1] .

  12. Reference Model for Control and Automation Systems in Electrical Power

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    (October 2005) | Department of Energy Model for Control and Automation Systems in Electrical Power (October 2005) Reference Model for Control and Automation Systems in Electrical Power (October 2005) Modern infrastructure automation systems are threatened by cyber attack. Their higher visibility in recent years and the increasing use of modern information technology (IT) components contribute to increased security risk. A means of analyzing these infrastructure automation systems is needed

  13. Reference Model 6 (RM6): Oscillating Wave Energy Converter.

    SciTech Connect (OSTI)

    Bull, Diana L; Smith, Chris; Jenne, Dale Scott; Jacob, Paul; Copping, Andrea; Willits, Steve; Fontaine, Arnold; Brefort, Dorian; Gordon, Margaret Ellen; Copeland, Robert; Jepsen, Richard A.

    2014-10-01

    This report is an addendum to SAND2013-9040: Methodology for Design and Economic Analysis of Marine Energy Conversion (MEC) Technologies. This report describes an Oscillating Water Column Wave Energy Converter reference model design in a complementary manner to Reference Models 1-4 contained in the above report. In this report, a conceptual design for an Oscillating Water Column Wave Energy Converter (WEC) device appropriate for the modeled reference resource site was identified, and a detailed backward bent duct buoy (BBDB) device design was developed using a combination of numerical modeling tools and scaled physical models. Our team used the methodology in SAND2013-9040 for the economic analysis that included costs for designing, manufacturing, deploying, and operating commercial-scale MEC arrays, up to 100 devices. The methodology was applied to identify key cost drivers and to estimate levelized cost of energy (LCOE) for this RM6 Oscillating Water Column device in dollars per kilowatt-hour (%24/kWh). Although many costs were difficult to estimate at this time due to the lack of operational experience, the main contribution of this work was to disseminate a detailed set of methodologies and models that allow for an initial cost analysis of this emerging technology. This project is sponsored by the U.S. Department of Energy's (DOE) Wind and Water Power Technologies Program Office (WWPTO), within the Office of Energy Efficiency & Renewable Energy (EERE). Sandia National Laboratories, the lead in this effort, collaborated with partners from National Laboratories, industry, and universities to design and test this reference model.

  14. References and Other Bibliographic Works by Author - Compliance

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    References & Links 48CFR Chapter 9, Acquisition Regulation (DEAR) Department of Energy Acquisition Requirements (DEAR) DOE Order 470.4B, Safeguards and Security Program DOE Order 472.2, Personnel Security DOE Order 206.2 DOE Order 470.4B Executive Order 10865 Executive Order 12968 Federal Acquisition Regulation (FAR) Federal Bureau of Investigations FIPS PUB 201-2, Personal Identity Verification (PIV) of Federal Employees and Contractors Intelligence Reform and Terrorism Prevention Act of

  15. Technical Reference on Hydrogen Compatibility of Materials Austenitic Stainless Steels:

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Type 304 & 304L (code 2101) Prepared by: C. San Marchi, Sandia National Laboratories Editors C. San Marchi B.P. Somerday Sandia National Laboratories This report may be updated and revised periodically in response to the needs of the technical community; up-to-date versions can be requested from the editors at the address given below. The success of this reference depends upon feedback from the technical community; please forward your comments, suggestions, criticisms and relevant public-

  16. Technical Reference on Hydrogen Compatibility of Materials Austenitic Stainless Steels:

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    21-6-9 (code 2202) Prepared by: C. San Marchi, Sandia National Laboratories Editors C. San Marchi B.P. Somerday Sandia National Laboratories This report may be updated and revised periodically in response to the needs of the technical community; up-to-date versions can be requested from the editors at the address given below. The success of this reference depends upon feedback from the technical community; please forward your comments, suggestions, criticisms and relevant public- domain data to:

  17. Technical Reference on Hydrogen Compatibility of Materials Austenitic Stainless Steels:

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    A-286 (code 2301) Prepared by: C. San Marchi, Sandia National Laboratories Editors C. San Marchi B.P. Somerday Sandia National Laboratories This report may be updated and revised periodically in response to the needs of the technical community; up-to-date versions can be requested from the editors at the address given below. The success of this reference depends upon feedback from the technical community; please forward your comments, suggestions, criticisms and relevant public- domain data to:

  18. Temperature compensated current sensor using reference magnetic field

    DOE Patents [OSTI]

    Yakymyshyn, Christopher Paul (Seminole, FL); Brubaker, Michael Allen (Loveland, CO); Yakymyshyn, Pamela Jane (Seminole, FL)

    2007-10-09

    A method is described to provide temperature compensation and self-calibration of a current sensor based on a plurality of magnetic field sensors positioned around a current carrying conductor. A reference magnetic field generated within the current sensor housing is detected by a separate but identical magnetic field sensor and is used to correct variations in the output signal due to temperature variations and aging.

  19. Development of Compact Gaseous Sensors with Internal Reference for

    Broader source: Energy.gov (indexed) [DOE]

    Monitoring O2 and NOx in Combustion Environments | Department of Energy Compact sensors have been developed to allow for real-time monitoring of O2 and NOx during combustion. PDF icon deer08_singh.pdf More Documents & Publications Compact Electrochemical Bi-functional NOx/O2 Sensors with an Internal Reference for High Temperature Applications Compact Potentiometric NOx Sensor Compact Potentiometric NOx Sensor

  20. Lawrence Livermore National Laboratory Working Reference Material Production Pla

    SciTech Connect (OSTI)

    Amy Wong; Denise Thronas; Robert Marshall

    1998-11-04

    This Lawrence Livermore National Laboratory (LLNL) Working Reference Material Production Plan was written for LLNL by the Los Alamos National Laboratory to address key elements of producing seven Pu-diatomaceous earth NDA Working Reference Materials (WRMS). These WRMS contain low burnup Pu ranging in mass from 0.1 grams to 68 grams. The composite Pu mass of the seven WRMS was designed to approximate the maximum TRU allowable loading of 200 grams Pu. This document serves two purposes: first, it defines all the operations required to meet the LLNL Statement of Work quality objectives, and second, it provides a record of the production and certification of the WRMS. Guidance provided in ASTM Standard Guide C1128-89 was used to ensure that this Plan addressed all the required elements for producing and certifying Working Reference Materials. The Production Plan was written to provide a general description of the processes, steps, files, quality control, and certification measures that were taken to produce the WRMS. The Plan identifies the files where detailed procedures, data, quality control, and certification documentation and forms are retained. The Production Plan is organized into three parts: a) an initial section describing the preparation and characterization of the Pu02 and diatomaceous earth materials, b) middle sections describing the loading, encapsulation, and measurement on the encapsulated WRMS, and c) final sections describing the calculations of the Pu, Am, and alpha activity for the WRMS and the uncertainties associated with these quantities.

  1. Tracking stochastic resonance curves using an assisted reference model

    SciTech Connect (OSTI)

    Caldern Ramrez, Mario; Rico Martnez, Ramiro; Parmananda, P.

    2015-06-15

    The optimal noise amplitude for Stochastic Resonance (SR) is located employing an Artificial Neural Network (ANN) reference model with a nonlinear predictive capability. A modified Kalman Filter (KF) was coupled to this reference model in order to compensate for semi-quantitative forecast errors. Three manifestations of stochastic resonance, namely, Periodic Stochastic Resonance (PSR), Aperiodic Stochastic Resonance (ASR), and finally Coherence Resonance (CR) were considered. Using noise amplitude as the control parameter, for the case of PSR and ASR, the cross-correlation curve between the sub-threshold input signal and the system response is tracked. However, using the same parameter the Normalized Variance curve is tracked for the case of CR. The goal of the present work is to track these curves and converge to their respective extremal points. The ANN reference model strategy captures and subsequently predicts the nonlinear features of the model system while the KF compensates for the perturbations inherent to the superimposed noise. This technique, implemented in the FitzHugh-Nagumo model, enabled us to track the resonance curves and eventually locate their optimal (extremal) values. This would yield the optimal value of noise for the three manifestations of the SR phenomena.

  2. 2010 Annual Merit Review Results Cross Reference of PIs and Organizati...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Projects, and Organizations DOE Vehicle Technologies Program 2009 Merit Review Report - PI and Project Cross Reference 2013 Annual Merit Review Results Report - Cross-Reference of ...

  3. Uranium Certified Reference Materials Price List | U.S. DOE Office...

    Office of Science (SC) Website

    NBL Program Office Home About Programs Certified Reference Materials (CRMs) Prices and ... Prices and Certificates Uranium Certified Reference Materials Price List Print Text Size: ...

  4. Autonomous Demand Response for Primary Frequency Regulation

    SciTech Connect (OSTI)

    Donnelly, Matt; Trudnowski, Daniel J.; Mattix, S.; Dagle, Jeffery E.

    2012-02-28

    The research documented within this report examines the use of autonomous demand response to provide primary frequency response in an interconnected power grid. The work builds on previous studies in several key areas: it uses a large realistic model (i.e., the interconnection of the western United States and Canada); it establishes a set of metrics that can be used to assess the effectiveness of autonomous demand response; and it independently adjusts various parameters associated with using autonomous demand response to assess effectiveness and to examine possible threats or vulnerabilities associated with the technology.

  5. Clean coal reference plants: Atmospheric CFB. Topical report, Task 1

    SciTech Connect (OSTI)

    Rubow, L.N.; Harvey, L.E.; Buchanan, T.L.; Carpenter, R.G.; Hyre, M.R.; Zaharchuk, R.

    1992-06-01

    The Clean Coal Technology Demonstration Program is a government and industry cofunded technology development effort to demonstrate a new generation of innovative coal utilization processes in a series of full-scale facilities. The goal of the program is to provide the US energy marketplace with a number of advanced, more efficient and environmentally responsive coal-using technologies. The Morgantown Energy Technology Center (METC) has the responsibility for monitoring the CCT Projects within certain technology categories, which correspond to the center`s areas of technology development, including atmospheric fluidized bed combustion, pressurized fluidized bed combustion, integrated gasification combined cycle, mild gasification, and industrial applications. A measure of success in the CCT program will be the commercial acceptance of the new technologies being demonstrated. The dissemination of project information to potential users is being accomplished by producing a series of reference plant designs which will provide the users a basis for the selection of technologies applicable to their future energy requirements. As a part of DOE`s monitoring and evaluation of the CCT Projects, Gilbert/Commonwealth (G/C) has been contracted to assist in this effort by producing the design of a commercial size Reference Plant, utilizing technologies developed in the CCT Program. This report, the first in a series, describes the design of a 400 MW electric power plant, utilizing an atmospheric pressure, circulating fluidized bed combustor (ACFB) similar to the one which was demonstrated at Colorado-Ute`s Nucla station, funded in Round 1 of the CCT Program. The intent of the reference plant design effort was to portray a commercial power plant with attributes considered important to the utility industry. The logical choice for the ACFB combustor was Pyropower since they supplied the ACFB for the Nucla Project.

  6. High Flux Isotope Reactor cold neutron source reference design concept

    SciTech Connect (OSTI)

    Selby, D.L.; Lucas, A.T.; Hyman, C.R.

    1998-05-01

    In February 1995, Oak Ridge National Laboratory`s (ORNL`s) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH{sub 2}) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH{sub 2} cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept.

  7. Preliminary Reference Case Results for Oil and Natural Gas

    U.S. Energy Information Administration (EIA) Indexed Site

    Preliminary Reference Case Results for Oil and Natural Gas AEO2014 Oil and Gas Supply Working Group Meeting Office of Petroleum, Gas, and Biofuels Analysis September 26, 2013 | Washington, DC WORKING GROUP PRESENTATION FOR DISCUSSION PURPOSES DO NOT QUOTE OR CITE AS RESULTS ARE SUBJECT TO CHANGE AEO2014P uses ref2014.d092413a AEO2013 uses ref2013.d102312a Changes for AEO2014 2 * Revised shale & tight play resources (EURs, type curves) * Updated classification of shale gas, tight gas, &

  8. Quantum chaos and order based on classically moving reference frames

    SciTech Connect (OSTI)

    Hai Wenhua [Department of Physics, Hunan Normal University, Changsha 410081 (China); Department of Physics, Jishou University, Jishou 416000, Hunan (China); Xie Qiongtao; Fang Jianshu [Department of Physics, Hunan Normal University, Changsha 410081 (China)

    2005-07-15

    We develop a mathematically consistent approach for treating the quantum systems based on moving classical reference frames. The classical and quantum exact solutions show excellently classical-quantum correspondence, in which the quantum chaotic coherent states correspond to the classically chaotic motions. Applying the approach to the periodically driven linear and nonlinear oscillators, the regular and chaotic quantum states and quantum levels, and the quantum chaotic regions are evidenced. The results indicate that chaos may cause the collapse of matter wave packets and suppress the quantum effect of energy.

  9. Multiple Reference Fourier Transform Holography: Five Images for the Price

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of One Multiple Reference Fourier Transform Holography: Five Images for the Price of One Improving the quality of a high magnification image on an optical microscope is simply a matter of cranking up the intensity of the illumination lamp. The same is true for x-ray microscopes, but complications arise when there just aren't enough x-rays or even worse when the sample is susceptible to damage caused by the intense x-ray beam. To address these challenges we have demonstrated a novel technique

  10. LCCP Desktop Application v1.0 Engineering Reference

    SciTech Connect (OSTI)

    Beshr, Mohamed; Aute, Vikrant

    2014-04-01

    This Life Cycle Climate Performance (LCCP) Desktop Application Engineering Reference is divided into three parts. The first part of the guide, consisting of the LCCP objective, literature review, and mathematical background, is presented in Sections 2-4. The second part of the guide (given in Sections 5-10) provides a description of the input data required by the LCCP desktop application, including each of the input pages (Application Information, Load Information, and Simulation Information) and details for interfacing the LCCP Desktop Application with the VapCyc and EnergyPlus simulation programs. The third part of the guide (given in Section 11) describes the various interfaces of the LCCP code.

  11. JEDI Marine and Hydrokinetic Model: User Reference Guide

    SciTech Connect (OSTI)

    Goldberg, M.; Previsic, M.

    2011-04-01

    The Jobs and Economic Development Impact Model (JEDI) for Marine and Hydrokinetics (MHK) is a user-friendly spreadsheet-based tool designed to demonstrate the economic impacts associated with developing and operating MHK power systems in the United States. The JEDI MHK User Reference Guide was developed to assist users in using and understanding the model. This guide provides information on the model's underlying methodology, as well as the sources and parameters used to develop the cost data utilized in the model. This guide also provides basic instruction on model add-in features, operation of the model, and a discussion of how the results should be interpreted.

  12. Reference Model 5 (RM5): Oscillating Surge Wave Energy Converter

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Model 5 (RM5): Oscillating Surge Wave Energy Converter Y.-H. Yu, D.S. Jenne, and R. Thresher National Renewable Energy Laboratory A. Copping, S. Geerlofs, and L.A. Hanna Pacific Northwest National Laboratory Technical Report NREL/TP-5000-62861 January 2015 NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Operated by the Alliance for Sustainable Energy, LLC This report is available at no cost from the National Renewable

  13. Ion source with improved primary arc collimation

    DOE Patents [OSTI]

    Dagenhart, William K.

    1985-01-01

    An improved negative ion source is provided in which a self-biasing, molybdenum collimator is used to define the primary electron stream arc discharge from a filament operated at a negative potential. The collimator is located between the anode and the filament. It is electrically connected to the anode by means of an appropriate size resistor such that the collimator is biased at essentially the filament voltage during operation. Initially, the full arc voltage appears across the filament to collimator until the arc discharge strikes. Then the collimator biases itself to essentially filament potential due to current flow through the resistor thus defining the primary electron stream without intercepting any appreciable arc power. The collimator aperture is slightly smaller than the anode aperture to shield the anode from the arc power, thereby preventing the exposure of the anode to the full arc power which, in the past, has caused overheating and erosion of the anode collimator during extended time pulsed-beam operation of the source. With the self-biasing collimator of this invention, the ion source may be operated from short pulse periods to steady-state without destroying the anode.

  14. Ion source with improved primary arc collimation

    DOE Patents [OSTI]

    Dagenhart, W.K.

    1983-12-16

    An improved negative ion source is provided in which a self-biasing, molybdenum collimator is used to define the primary electron stream arc discharge from a filament operated at a negative potential. The collimator is located between the anode and the filament. It is electrically connected to the anode by means of an appropriate size resistor such that the collimator is biased at essentially the filament voltage during operation. Initially, the full arc voltage appears across the filament to collimator until the arc discharge strikes. Then the collimator biases itself to essentially filament potential due to current flow through the resistor thus defining the primary electron stream without intercepting any appreciable arc power. The collimator aperture is slightly smaller than the anode aperture to shield the anode from the arc power which, in the past, has caused overheating and erosion of the anode collimator during extended time pulsed-beam operation of the source. With the self-biasing collimator of this invention, the ion source may be operated from short pulse periods to steady-state without destroying the anode.

  15. Table A3. Total First Use (formerly Primary Consumption) of...

    U.S. Energy Information Administration (EIA) Indexed Site

    ... and Ductile Iron Foundries",2,0," * "," * "," * ",31," W "," W ",29.3 3331," Primary Copper"," * ",0,0,0," W ",0,0," W ",1.1 3334," Primary Aluminum",40,0,0,0," W ",8," W "," W ...

  16. TORCH Computational Reference Kernels - A Testbed for Computer Science Research

    SciTech Connect (OSTI)

    Kaiser, Alex; Williams, Samuel Webb; Madduri, Kamesh; Ibrahim, Khaled; Bailey, David H.; Demmel, James W.; Strohmaier, Erich

    2010-12-02

    For decades, computer scientists have sought guidance on how to evolve architectures, languages, and programming models in order to improve application performance, efficiency, and productivity. Unfortunately, without overarching advice about future directions in these areas, individual guidance is inferred from the existing software/hardware ecosystem, and each discipline often conducts their research independently assuming all other technologies remain fixed. In today's rapidly evolving world of on-chip parallelism, isolated and iterative improvements to performance may miss superior solutions in the same way gradient descent optimization techniques may get stuck in local minima. To combat this, we present TORCH: A Testbed for Optimization ResearCH. These computational reference kernels define the core problems of interest in scientific computing without mandating a specific language, algorithm, programming model, or implementation. To compliment the kernel (problem) definitions, we provide a set of algorithmically-expressed verification tests that can be used to verify a hardware/software co-designed solution produces an acceptable answer. Finally, to provide some illumination as to how researchers have implemented solutions to these problems in the past, we provide a set of reference implementations in C and MATLAB.

  17. Reference Model 2: %22Rev 0%22 Rotor Design.

    SciTech Connect (OSTI)

    Barone, Matthew F.; Berg, Jonathan Charles; Griffith, Daniel

    2011-12-01

    The preliminary design for a three-bladed cross-flow rotor for a reference marine hydrokinetic turbine is presented. A rotor performance design code is described, along with modifications to the code to allow prediction of blade support strut drag as well as interference between two counter-rotating rotors. The rotor is designed to operate in a reference site corresponding to a riverine environment. Basic rotor performance and rigid-body loads calculations are performed to size the rotor elements and select the operating speed range. The preliminary design is verified with a simple finite element model that provides estimates of bending stresses during operation. A concept for joining the blades and support struts is developed and analyzed with a separate finite element analysis. Rotor mass, production costs, and annual energy capture are estimated in order to allow calculations of system cost-of-energy. Evaluation Only. Created with Aspose.Pdf.Kit. Copyright 2002-2011 Aspose Pty Ltd Evaluation Only. Created with Aspose.Pdf.Kit. Copyright 2002-2011 Aspose Pty Ltd

  18. Secondary emission electron gun using external primaries

    DOE Patents [OSTI]

    Srinivasan-Rao, Triveni (Shoreham, NY); Ben-Zvi, Ilan (Setauket, NY)

    2009-10-13

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  19. Secondary emission electron gun using external primaries

    DOE Patents [OSTI]

    Srinivasan-Rao, Triveni (Shoreham, NY); Ben-Zvi, Ilan (Setauket, NY); Kewisch, Jorg (Wading River, NY); Chang, Xiangyun (Middle Island, NY)

    2007-06-05

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  20. Revised Analyses of Decommissioning Reference Non-Fuel-Cycle Facilities

    SciTech Connect (OSTI)

    MC Bierschbach; DR Haffner; KJ Schneider; SM Short

    2002-12-01

    Cost information is developed for the conceptual decommissioning of non-fuel-cycle nuclear facilities that represent a significant decommissioning task in terms of decontamination and disposal activities. This study is a re-evaluation of the original study (NUREG/CR-1754 and NUREG/CR-1754, Addendum 1). The reference facilities examined in this study are the same as in the original study and include: a laboratory for the manufacture of {sup 3}H-labeled compounds; a laboratory for the manufacture of {sup 14}C-labeled compounds; a laboratory for the manufacture of {sup 123}I-labeled compounds; a laboratory for the manufacture of {sup 137}Cs sealed sources; a laboratory for the manufacture of {sup 241}Am sealed sources; and an institutional user laboratory. In addition to the laboratories, three reference sites that require some decommissioning effort were also examined. These sites are: (1) a site with a contaminated drain line and hold-up tank; (2) a site with a contaminated ground surface; and (3) a tailings pile containing uranium and thorium residues. Decommissioning of these reference facilities and sites can be accomplished using techniques and equipment that are in common industrial use. Essentially the same technology assumed in the original study is used in this study. For the reference laboratory-type facilities, the study approach is to first evaluate the decommissioning of individual components (e.g., fume hoods, glove boxes, and building surfaces) that are common to many laboratory facilities. The information obtained from analyzing the individual components of each facility are then used to determine the cost, manpower requirements and dose information for the decommissioning of the entire facility. DECON, the objective of the 1988 Rulemaking for materials facilities, is the decommissioning alternative evaluated for the reference laboratories because it results in the release of the facility for restricted or unrestricted use as soon as possible. For a facility, DECON requires that contaminated components either be: (1) decontaminated to restricted or unrestricted release levels or (2) packaged and shipped to an authorized disposal site. This study considers unrestricted release only. The new decommissioning criteria of July 1997 are too recent for this study to include a cost analysis of the restricted release option, which is now allowed under these new criteria. The costs of decommissioning facility components are generally estimated to be in the range of $140 to $27,000, depending on the type of component, the type and amount of radioactive contamination, the remediation options chosen, and the quantity of radioactive waste generated from decommissioning operations. Estimated costs for decommissioning the example laboratories range from $130,000 to $205,000, assuming aggressive low-level waste (LLW) volume reduction. If only minimal LLW volume reduction is employed, decommissioning costs range from $150,000 to $270,000 for these laboratories. On the basis of estimated decommissioning costs for facility components, the costs of decommissioning typical non-fuel-cycle laboratory facilities are estimated to range from about $25,000 for the decommissioning of a small room containing one or two fume hoods to more than $1 million for the decommissioning of an industrial plant containing several laboratories in which radiochemicals and sealed radioactive sources are prepared. For the reference sites of this study, the basic decommissioning alternatives are: (1) site stabilization followed by long-term care and (2) removal of the waste or contaminated soil to an authorized disposal site. Cost estimates made for decommissioning three reference sites range from about $130,000 for the removal of a contaminated drain line and hold-up tank to more than $23 million for the removal of a tailings pile that contains radioactive residue from ore-processing operations in which tin slag is processed for the recovery of rare metals. Total occupational radiation doses generally range from 0.00007 person-rem to 13 person-rem for decommissioning the laboratory facilities of this study. The results of this study are: (1) decommissioning costs have continued to increase since publication of the original study, due primarily to rapidly escalating costs for disposal of radioactive wastes at the available LLW burial sites; (2) these swiftly increasing LLW disposal costs provide a significant incentive for NRC licensees to effectively manage LLW generation, treatment, and disposal from decommissioning activities; and (3) decommissioning costs have increased on the order of 34% to 66% since the Final Decommissioning Rule was issued in 1988, due in large part to the 3.5-fold increase in burial costs.

  1. Combustor with two stage primary fuel assembly

    DOE Patents [OSTI]

    Sharifi, Mehran; Zolyomi, Wendel; Whidden, Graydon Lane

    2000-01-01

    A combustor for a gas turbine having first and second passages for pre-mixing primary fuel and air supplied to a primary combustion zone. The flow of fuel to the first and second pre-mixing passages is separately regulated using a single annular fuel distribution ring having first and second row of fuel discharge ports. The interior portion of the fuel distribution ring is divided by a baffle into first and second fuel distribution manifolds and is located upstream of the inlets to the two pre-mixing passages. The annular fuel distribution ring is supplied with fuel by an annular fuel supply manifold, the interior portion of which is divided by a baffle into first and second fuel supply manifolds. A first flow of fuel is regulated by a first control valve and directed to the first fuel supply manifold, from which the fuel is distributed to first fuel supply tubes that direct it to the first fuel distribution manifold. From the first fuel distribution manifold, the first flow of fuel is distributed to the first row of fuel discharge ports, which direct it into the first pre-mixing passage. A second flow of fuel is regulated by a second control valve and directed to the second fuel supply manifold, from which the fuel is distributed to second fuel supply tubes that direct it to the second fuel distribution manifold. From the second fuel distribution manifold, the second flow of fuel is distributed to the second row of fuel discharge ports, which direct it into the second pre-mixing passage.

  2. Repeatable reference for positioning sensors and transducers in drill pipe

    DOE Patents [OSTI]

    Hall, David R.; Fox, Joe; Pixton, David S.; Hall, Jr., H. Tracy

    2005-05-03

    A drill pipe having a box end having a tapered thread, and an internal shoulder and an external face for engagement with a drill pipe pin end having a tapered mating thread, and an external shoulder and an external face adapted for data acquisition or transmission. The relative dimensions of the box and pin ends are precisely controlled so that when the tool joint is made up, a repeatable reference plane is established for transmitting power and tuning downhole sensors, transducers, and means for sending and receiving data along the drill string. When the power or data acquisition and transmission means are located in the tool joint, the dimensions of the tool joint are further proportioned to compensate for the loss of cross-sectional area in order maintain the joints ability to sustain nominal makeup torque.

  3. Production of Working Reference Materials for the Capability Evaluation Project

    SciTech Connect (OSTI)

    Phillip D. Noll, Jr.; Robert S. Marshall

    1999-03-01

    Nondestructive waste assay (NDA) methods are employed to determine the mass and activity of waste-entrained radionuclides as part of the National TRU (Trans-Uranic) Waste Characterization Program. In support of this program the Idaho National Engineering and Environmental Laboratory Mixed Waste Focus Area developed a plan to acquire capability/performance data on systems proposed for NDA purposes. The Capability Evaluation Project (CEP) was designed to evaluate the NDA systems of commercial contractors by subjecting all participants to identical tests involving 55 gallon drum surrogates containing known quantities and distributions of radioactive materials in the form of sealed-source standards, referred to as working reference materials (WRMs). Although numerous Pu WRMs already exist, the CEP WRM set allows for the evaluation of the capability and performance of systems with respect to waste types/configurations which contain increased amounts of {sup 241}Am relative to weapons grade Pu, waste that is dominantly {sup 241}Am, as well as wastes containing various proportions of depleted uranium. The CEP WRMs consist of a special mixture of PuO{sub 2}/AmO{sub 2} (IAP) and diatomaceous earth (DE) or depleted uranium (DU) oxide and DE and were fabricated at Los Alamos National Laboratory. The IAP WRMS are contained inside a pair of welded inner and outer stainless steel containers. The DU WRMs are singly contained within a stainless steel container equivalent to the outer container of the IAP standards. This report gives a general overview and discussion relating to the production and certification of the CEP WRMs.

  4. Direct-to-digital holography reduction of reference hologram noise and fourier space smearing

    DOE Patents [OSTI]

    Voelkl, Edgar

    2006-06-27

    Systems and methods are described for reduction of reference hologram noise and reduction of Fourier space smearing, especially in the context of direct-to-digital holography (off-axis interferometry). A method of reducing reference hologram noise includes: recording a plurality of reference holograms; processing the plurality of reference holograms into a corresponding plurality of reference image waves; and transforming the corresponding plurality of reference image waves into a reduced noise reference image wave. A method of reducing smearing in Fourier space includes: recording a plurality of reference holograms; processing the plurality of reference holograms into a corresponding plurality of reference complex image waves; transforming the corresponding plurality of reference image waves into a reduced noise reference complex image wave; recording a hologram of an object; processing the hologram of the object into an object complex image wave; and dividing the complex image wave of the object by the reduced noise reference complex image wave to obtain a reduced smearing object complex image wave.

  5. Dose homogeneity specification for reference dosimetry of nonstandard fields

    SciTech Connect (OSTI)

    Chung, Eunah; Soisson, Emilie; Seuntjens, Jan [Medical Physics Unit, McGill University, Montreal General Hospital (L5-113), 1650 Cedar Avenue, Montreal, Quebec H3G 1A4 (Canada); Medical Physics Unit, McGill University and Department of Medical Physics, McGill University Health Centre, Montreal General Hospital (L5-113), 1650 Cedar Avenue, Montreal, Quebec H3G 1A4 (Canada); Medical Physics Unit, McGill University, Montreal General Hospital (L5-113), 1650 Cedar Avenue, Montreal, Quebec H3G 1A4 (Canada)

    2012-01-15

    Purpose: To investigate the sensitivity of the plan-class specific correction factor to dose distributions in composite nonstandard field dosimetry. Methods: A cylindrical water-filled PMMA phantom was constructed at the center of which reference absorbed dose could be measured. Ten different TomoTherapy-based IMRT fields were created on the CT images of the phantom. The dose distribution for each IMRT field was estimated at the position of a radiation detector or ionization chamber. The dose in each IMRT field normalized to that in a reference 10 x 10 cm{sup 2} field was measured using a PTW micro liquid ion chamber. Based on the new dosimetry formalism, a plan-class specific correction factor k{sub Q{sub p{sub c{sub s{sub r,Q}{sup f{sub p}{sub c}{sub s}{sub r},f{sub r}{sub e}{sub f}}}}}} for each field was measured for two Farmer-type chambers, Exradin A12 and NE2571, as well as for a smaller Exradin A1SL chamber. The dependence of the measured correction factor on parameters characterizing dose distribution was analyzed. Results: Uncertainty on the plan-class specific correction factor measurement was in the range of 0.3%-0.5% and 0.3%-0.8% for the Farmer-type chambers and the Exradin A1SL, respectively. When the heterogeneity of the central region of the target volume was less than 5%, the correction factor did not differ from unity by more than 0.7% for the three air-filled ionization chambers. For more heterogeneous dose deliveries, the correction factor differed from unity by up to 2.4% for the Farmer-type chambers. For the Exradin A1SL, the correction factor was closer to unity due to the reduced effect of dose gradients, while it was highly variable in different IMRT fields because of a more significant impact of positioning uncertainties on the response of this chamber. Conclusions: The authors have shown that a plan-class specific correction factor can be specified as a function of plan evaluation parameters especially for Farmer-type chambers. This work provides a recipe based on quantifying dose distribution to accurately select air-filled ionization chamber correction factors for nonstandard fields.

  6. Zimbabwe-Terms of Reference for Future LEDS | Open Energy Information

    Open Energy Info (EERE)

    (Redirected from CDKN-Zimbabwe-Terms of Reference for Future LEDS) Jump to: navigation, search Name Zimbabwe-Terms of Reference for Future LEDS AgencyCompany Organization Climate...

  7. Coal-by-Rail: A Business-as-Usual Reference Case | Argonne National...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Coal-by-Rail: A Business-as-Usual Reference Case Title Coal-by-Rail: A Business-as-Usual Reference Case Publication Type Report Year of Publication 2015 Authors Mintz, MM, Saricks,...

  8. Reference reactor module for NASA's lunar surface fission power system

    SciTech Connect (OSTI)

    Poston, David I; Kapernick, Richard J; Dixon, David D; Werner, James; Qualls, Louis; Radel, Ross

    2009-01-01

    Surface fission power systems on the Moon and Mars may provide the first US application of fission reactor technology in space since 1965. The Affordable Fission Surface Power System (AFSPS) study was completed by NASA/DOE to determine the cost of a modest performance, low-technical risk surface power system. The AFSPS concept is now being further developed within the Fission Surface Power (FSP) Project, which is a near-term technology program to demonstrate system-level TRL-6 by 2013. This paper describes the reference FSP reactor module concept, which is designed to provide a net power of 40 kWe for 8 years on the lunar surface; note, the system has been designed with technologies that are fully compatible with a Martian surface application. The reactor concept uses stainless-steel based. UO{sub 2}-fueled, pumped-NaK fission reactor coupled to free-piston Stirling converters. The reactor shielding approach utilizes both in-situ and launched shielding to keep the dose to astronauts much lower than the natural background radiation on the lunar surface. The ultimate goal of this work is to provide a 'workhorse' power system that NASA can utilize in near-term and future Lunar and Martian mission architectures, with the eventual capability to evolve to very high power, low mass systems, for either surface, deep space, and/or orbital missions.

  9. Reference material manufacture and certification for the AVNG

    SciTech Connect (OSTI)

    Hauck, Danielle K; Mac Arthur, Duncan; Thron, Jonathan L; Livke, Alexander; Kondratov, Sergey; Razinkov, Sergey

    2010-01-01

    Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. The AVNG implementation that we describe is an attribute measurement system built by RFNC - VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass > 2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' The AVNG was tested using a number of reference material (RM) sources with masses and isotopic ratios above and below these thresholds. The AVNG was demonstrated in June 2009 using several of these sources in addition to detector calibration sources. Since the AVNG was designed to measure multi-kg plutonium sources, the RM was manufactured specifically for use with this system. In addition, the RM was used to test the thresholds in the AVNG, so the size and composition of each RM was certified prior to use. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

  10. High-temperature potentiometric oxygen sensor with internal reference

    DOE Patents [OSTI]

    Routbort, Jules L.; Singh, Dileep; Dutta, Prabir K.; Ramasamy, Ramamoorthy; Spirig, John V.; Akbar, Sheikh

    2011-11-15

    A compact oxygen sensor is provided, comprising a mixture of metal and metal oxide an enclosure containing said mixture, said enclosure capable of isolating said mixture from an environment external of said enclosure, and a first wire having a first end residing within the enclosure and having a second end exposed to the environment. Also provided is a method for the fabrication of an oxygen sensor, the method comprising confining a metal-metal oxide solid mixture to a container which consists of a single material permeable to oxygen ions, supplying an electrical conductor having a first end and a second end, whereby the first end resides inside the container as a reference (PO.sub.2).sup.ref, and the second end resides outside the container in the atmosphere where oxygen partial pressure (PO.sub.2).sup.ext is to be measured, and sealing the container with additional single material such that grain boundary sliding occurs between grains of the single material and grains of the additional single material.

  11. Multiple Whole Genome Alignments Without a Reference Organism

    SciTech Connect (OSTI)

    Dubchak, Inna; Poliakov, Alexander; Kislyuk, Andrey; Brudno, Michael

    2009-01-16

    Multiple sequence alignments have become one of the most commonly used resources in genomics research. Most algorithms for multiple alignment of whole genomes rely either on a reference genome, against which all of the other sequences are laid out, or require a one-to-one mapping between the nucleotides of the genomes, preventing the alignment of recently duplicated regions. Both approaches have drawbacks for whole-genome comparisons. In this paper we present a novel symmetric alignment algorithm. The resulting alignments not only represent all of the genomes equally well, but also include all relevant duplications that occurred since the divergence from the last common ancestor. Our algorithm, implemented as a part of the VISTA Genome Pipeline (VGP), was used to align seven vertebrate and sixDrosophila genomes. The resulting whole-genome alignments demonstrate a higher sensitivity and specificity than the pairwise alignments previously available through the VGP and have higher exon alignment accuracy than comparable public whole-genome alignments. Of the multiple alignment methods tested, ours performed the best at aligning genes from multigene families?perhaps the most challenging test for whole-genome alignments. Our whole-genome multiple alignments are available through the VISTA Browser at http://genome.lbl.gov/vista/index.shtml.

  12. Measurement Uncertainty Analysis of an Accelerometer Calibration Using a POC Electromagnetic Launcher

    SciTech Connect (OSTI)

    Timpson, Erik J.; Engel, T. G.

    2012-06-12

    A pulse forming network (PFN), helical electromagnetic launcher (HEML), command module (CM), and calibration table (CT) were built and evaluated for the combined ability to calibrate an accelerometer. The PFN has a maximum stored nergy of 19.25 kJ bank and is fired by a silicon controlled rectifier (SCR), with appropriate safety precautions. The HEML is constructed out of G-10 fiberglass reinforced epoxy and is designed to accelerate a mass of 600 grams to a velocity of 10 meters per second. The CM is microcontroller-based running Arduino Software. The CM has a keypad input and 7 segment outputs of the PFN voltage and desired charging voltage. After entering a desired PFN voltage, the CM controls the charging of the PFN. When the two voltages are equal it sends a pulse to the SCR to fire the PFN and in turn, the HEML. The HEML projectiles tip hits a target that is held by the CT. The CT consists of a table to hold the PFN and HEML, a vacuum chuck, air bearing, velocimeter and catch pot. The target is held with the vacuum chuck awaiting impact. After impact, the air bearing allows the target to fall freely so that the velocimeter can accurately read. A known acceleration is determined from the known change in velocity of the target. Thus, if an accelerometer was attached to the target, the measured value can be compared to the known value.

  13. SBOT NEW YORK BROOKHAVEN LAB POC Jill Clough-Johnston Telephone

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Related Equipment Merchant Wholesalers 423610 Electrical and Electronic Appliance, Television, and Radio Set Merchant Wholesalers 423620 Other Electronic Parts and Equipment...

  14. POC-scale testing of an advanced fine coal dewatering equipment/technique

    SciTech Connect (OSTI)

    Groppo, J.G.; Parekh, B.K.; Rawls, P.

    1995-11-01

    Froth flotation technique is an effective and efficient process for recovering of ultra-fine (minus 74 {mu}m) clean coal. Economical dewatering of an ultra-fine clean coal product to a 20 percent level moisture will be an important step in successful implementation of the advanced cleaning processes. This project is a step in the Department of Energy`s program to show that ultra-clean coal could be effectively dewatered to 20 percent or lower moisture using either conventional or advanced dewatering techniques. As the contract title suggests, the main focus of the program is on proof-of-concept testing of a dewatering technique for a fine clean coal product. The coal industry is reluctant to use the advanced fine coal recovery technology due to the non-availability of an economical dewatering process. in fact, in a recent survey conducted by U.S. DOE and Battelle, dewatering of fine clean coal was identified as the number one priority for the coal industry. This project will attempt to demonstrate an efficient and economic fine clean coal slurry dewatering process.

  15. POC-Scale Testing of an Advanced Fine Coal Dewatering Equipment/Technique

    SciTech Connect (OSTI)

    B. K. Karekh; D. Tao; J. G. Groppo

    1998-08-28

    Froth flotation technique is an effective and efficient process for recovering of ultra-fine (minus 74 mm) clean coal. Economical dewatering of an ultra-fine clean coal product to a 20% level moisture will be an important step in successful implementation of the advanced cleaning processes. This project is a step in the Department of Energy's program to show that ultra-clean coal could be effectively dewatered to 20% or lower moisture using either conventional or advanced dewatering techniques. The cost-sharing contract effort is for 45 months beginning September 30, 1994. This report discusses technical progress made during the quarter from January 1 ? March 31, 1998.

  16. Chromosome abnormalities in primary ovarian cancer

    SciTech Connect (OSTI)

    Yonescu, R.; Currie, J.; Griffin, C.A.

    1994-09-01

    Chromosome abnormalities that are specific and recurrent may occur in regions of the genome that are involved in the conversion of normal cells to those with tumorigenic potential. Ovarian cancer is the primary cause of death among patients with gynecological malignancies. We have performed cytogenetic analysis of 16 ovarian tumors from women age 28-82. Three tumors of low malignant potential and three granulosa cell tumors had normal karyotypes. To look for the presence of trisomy 12, which has been suggested to be a common aberration in this group of tumors, interphase fluorescence in situ hybridization was performed on direct preparations from three of these tumors using a probe for alpha satellite sequences of chromosome 12. In the 3 preparations, 92-98 percent of the cells contained two copies of chromosome 12, indicating that trisomy 12 is not a universal finding in low grade ovarian tumors. Endometrioid carcinoma of the ovary is histologically indistinguishable from endometial carcinoma of the uterus. We studied 10 endometrioid tumors to determine the degree of genetic similarity between these two carcinomas. Six out of ten endometrioid tumors showed a near-triploid modal number, and one presented with a tetraploid modal number. Eight of the ten contained structural chromosome abnormalities, of which the most frequent were 1p- (5 tumors), 19q+ (3 tumors), 6q- or ins(6) (4 tumors), 3q- or 3q+ (4 tumors). These cytogenetic results resemble those reported for papillary ovarian tumors and differ from those of endometrial carcinoma of the uterus. We conclude that despite the histologic similarities between the endometrioid and endometrial carcinomas, the genetic abnormalities in the genesis of these tumors differ significantly.

  17. Fast computational methods for predicting protein structure from primary

    Office of Scientific and Technical Information (OSTI)

    amino acid sequence (Patent) | DOEPatents Data Explorer Search Results Fast computational methods for predicting protein structure from primary amino acid sequence Title: Fast computational methods for predicting protein structure from primary amino acid sequence The present invention provides a method utilizing primary amino acid sequence of a protein, energy minimization, molecular dynamics and protein vibrational modes to predict three-dimensional structure of a protein. The present

  18. Fast computational methods for predicting protein structure from primary

    Office of Scientific and Technical Information (OSTI)

    amino acid sequence (Patent) | DOEPatents Fast computational methods for predicting protein structure from primary amino acid sequence Title: Fast computational methods for predicting protein structure from primary amino acid sequence The present invention provides a method utilizing primary amino acid sequence of a protein, energy minimization, molecular dynamics and protein vibrational modes to predict three-dimensional structure of a protein. The present invention also determines possible

  19. Feeding Arteries of Primary Tongue Cancers on Intra-arterial...

    Office of Scientific and Technical Information (OSTI)

    on Intra-arterial Infusion Chemotherapy Citation Details In-Document Search Title: Feeding Arteries of Primary Tongue Cancers on Intra-arterial Infusion Chemotherapy PurposeTo ...

  20. Light Absorption of Primary Organic Aerosol Paper Named ACS Editors...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Absorption of Primary Organic Aerosol Paper Named ACS Editors' Choice For original submission and image(s), see ARM Research Highlights http:www.arm.govsciencehighlights...

  1. "Table 2. Real Average Annual Coal Transportation Costs, By Primary...

    U.S. Energy Information Administration (EIA) Indexed Site

    Real Average Annual Coal Transportation Costs, By Primary Transport Mode and Supply Region" "(2013 dollars per ton)" "Coal Supply Region",2008,2009,2010,2011,2012,2013 "Railroad"...

  2. Estimation of net primary productivity using a process-based...

    Office of Scientific and Technical Information (OSTI)

    Journal Article: Estimation of net primary productivity using a process-based model in Gansu Province, Northwest China Citation Details In-Document Search Title: Estimation of net ...

  3. Primary Science of Energy Teacher and Student Guides (42 Activities...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Teacher and Student Guides (42 Activities) Primary Science of Energy Teacher and Student Guides (42 Activities) Below is information about the student activitylesson plan from...

  4. Xyce Parallel Electronic Simulator Reference Guide Version 6.4

    SciTech Connect (OSTI)

    Keiter, Eric R.; Mei, Ting; Russo, Thomas V.; Schiek, Richard; Sholander, Peter E.; Thornquist, Heidi K.; Verley, Jason; Baur, David Gregory

    2015-12-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce . This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide [1] . Trademarks The information herein is subject to change without notice. Copyright c 2002-2015 Sandia Corporation. All rights reserved. Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Portions of the Xyce TM code are: Copyright c 2002, The Regents of the University of California. Produced at the Lawrence Livermore National Laboratory. Written by Alan Hindmarsh, Allan Taylor, Radu Serban. UCRL-CODE-2002-59 All rights reserved. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. Xyce 's expression library is based on that inside Spice 3F5 developed by the EECS Department at the University of California. The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. All other trademarks are property of their respective owners. Contacts Bug Reports (Sandia only) http://joseki.sandia.gov/bugzilla http://charleston.sandia.gov/bugzilla World Wide Web http://xyce.sandia.gov http://charleston.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only)

  5. Large Synoptic Survey Telescope: From Science Drivers to Reference Design

    SciTech Connect (OSTI)

    Ivezic, Z.; Axelrod, T.; Brandt, W.N.; Burke, D.L.; Claver, C.F.; Connolly, A.; Cook, K.H.; Gee, P.; Gilmore, D.K.; Jacoby, S.H.; Jones, R.L.; Kahn, S.M.; Kantor, J.P.; Krabbendam, V.; Lupton, R.H.; Monet, D.G.; Pinto, P.A.; Saha, A.; Schalk, T.L.; Schneider, D.P.; Strauss, Michael A.; /Washington U., Seattle, Astron. Dept. /LSST Corp. /Penn State U., Astron. Astrophys. /KIPAC, Menlo Park /NOAO, Tucson /LLNL, Livermore /UC, Davis /Princeton U., Astrophys. Sci. Dept. /Naval Observ., Flagstaff /Arizona U., Astron. Dept. - Steward Observ. /UC, Santa Cruz /Harvard U. /Johns Hopkins U. /Illinois U., Urbana

    2011-10-14

    In the history of astronomy, major advances in our understanding of the Universe have come from dramatic improvements in our ability to accurately measure astronomical quantities. Aided by rapid progress in information technology, current sky surveys are changing the way we view and study the Universe. Next-generation surveys will maintain this revolutionary progress. We focus here on the most ambitious survey currently planned in the visible band, the Large Synoptic Survey Telescope (LSST). LSST will have unique survey capability in the faint time domain. The LSST design is driven by four main science themes: constraining dark energy and dark matter, taking an inventory of the Solar System, exploring the transient optical sky, and mapping the Milky Way. It will be a large, wide-field ground-based system designed to obtain multiple images covering the sky that is visible from Cerro Pachon in Northern Chile. The current baseline design, with an 8.4 m (6.5 m effective) primary mirror, a 9.6 deg{sup 2} field of view, and a 3,200 Megapixel camera, will allow about 10,000 square degrees of sky to be covered using pairs of 15-second exposures in two photometric bands every three nights on average. The system is designed to yield high image quality, as well as superb astrometric and photometric accuracy. The survey area will include 30,000 deg{sup 2} with {delta} < +34.5{sup o}, and will be imaged multiple times in six bands, ugrizy, covering the wavelength range 320-1050 nm. About 90% of the observing time will be devoted to a deep-wide-fast survey mode which will observe a 20,000 deg{sup 2} region about 1000 times in the six bands during the anticipated 10 years of operation. These data will result in databases including 10 billion galaxies and a similar number of stars, and will serve the majority of science programs. The remaining 10% of the observing time will be allocated to special programs such as Very Deep and Very Fast time domain surveys. We describe how the LSST science drivers led to these choices of system parameters.

  6. Economic Analysis of the Reference Design for a Nuclear-Driven High-Temperature-Electrolysis Hydrogen Production Plant

    SciTech Connect (OSTI)

    E. A. Harvego; M. G. McKellar; M. S. Sohal; J. E. O'Brien; J. S. Herring

    2008-01-01

    A reference design for a commercial-scale high-temperature electrolysis (HTE) plant for hydrogen production was developed to provide a basis for comparing the HTE concept with other hydrogen production concepts. The reference plant design is driven by a high-temperature helium-cooled reactor coupled to a direct Brayton power cycle. The reference design reactor power is 600 MWt, with a primary system pressure of 7.0 MPa, and reactor inlet and outlet fluid temperatures of 540°C and 900°C, respectively. The electrolysis unit used to produce hydrogen consists of 4,009,177 cells with a per-cell active area of 225 cm2. A nominal cell area-specific resistance, ASR, value of 0.4 Ohm•cm2 with a current density of 0.25 A/cm2 was used, and isothermal boundary conditions were assumed. The optimized design for the reference hydrogen production plant operates at a system pressure of 5.0 MPa, and utilizes an air-sweep system to remove the excess oxygen that is evolved on the anode side of the electrolyzer. The inlet air for the air-sweep system is compressed to the system operating pressure of 5.0 MPa in a four-stage compressor with intercooling. The alternating current, AC, to direct current, DC, conversion is 96%. The overall system thermal-to-hydrogen production efficiency (based on the low heating value of the produced hydrogen) is 47.12% at a hydrogen production rate of 2.356 kg/s. An economic analysis of the plant was also performed using the H2A Analysis Methodology developed by the Department of Energy (DOE) Hydrogen Program. The results of the economic analysis demonstrated that the HTE hydrogen production plant driven by a high-temperature helium-cooled nuclear power plant can deliver hydrogen at a competitive cost using realistic financial and cost estimating assumptions. A required cost of $3.23 per kg of hydrogen produced was calculated assuming an internal rate of return of 10%. Approximately 73% of this cost ($2.36/kg) is the result of capital costs associated with the construction of the combined nuclear plant and hydrogen production facility. Operation and maintenance costs represent about 18% of the total cost ($0.57/kg). Variable costs (including the cost of nuclear fuel) contribute about 8.7% ($0.28/kg) to the total cost of hydrogen production, and decommissioning and raw material costs make up the remaining fractional cost.

  7. Levelized Cost of Energy Analysis of Marine and Hydrokinetic Reference Models: Preprint

    SciTech Connect (OSTI)

    Jenne, D. S.; Yu, Y. H.; Neary, V.

    2015-04-24

    In 2010 the U.S. Department of Energy initiated the development of six marine energy converter reference models. The reference models are point designs of well-known marine energy converters. Each device was designed to operate in a specific marine resource, instead of a generic device that can be deployed at any location. This method allows each device to be used as a benchmark for future reference model to benchmark future devices. The six designs consist of three current energy converters and three wave energy converters. The reference model project has generated both technical and economic data sets that are available in the public domain. The methodology to calculate the levelized cost of energy for the reference model project and an overall comparison of the cost of energy from these six reference-model designs are presented in this paper.

  8. 2008 Annual Merit Review Results Summary - 18. Cross-Reference of Project

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Investigators, Projects, and Organizations | Department of Energy 8. Cross-Reference of Project Investigators, Projects, and Organizations 2008 Annual Merit Review Results Summary - 18. Cross-Reference of Project Investigators, Projects, and Organizations DOE Vehicle Technologies Annual Merit Review PDF icon 2008_merit_review_18.pdf More Documents & Publications 2010 Annual Merit Review Results Cross Reference of PIs and Organizations DOE Vehicle Technologies Program 2009 Merit Review

  9. Microsoft Word - ORNL TM INFLOW CHARACTERISTICS FOR RIVER REFERENCE MODEL 2

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    360 Environmental Science Division Reference Inflow Characteristics for River Resource Reference Model: Reference Model 2 (RM2) Vincent S. Neary, Ph.D., P.E. Date Published: October 2011 Prepared by OAK RIDGE NATIONAL LABORATORY Oak Ridge, Tennessee 37831-6283 managed by UT-BATTELLE, LLC for the U.S. DEPARTMENT OF ENERGY under contract DE-AC05-00OR22725

  10. Plutonium Certified Reference Materials Price List | U.S. DOE Office of

    Office of Science (SC) Website

    Science (SC) Plutonium Certified Reference Materials Price List NBL Program Office NBL PO Home About Programs Certified Reference Materials (CRMs) Prices and Certificates Ordering Information NEPA Documents News Safety Data Sheets (SDS) for NBL Program Office Certified Reference Materials (CRM) Contact Information NBL Program Office U.S. Department of Energy Building 201 9800 South Cass Avenue Argonne, IL 60439-4899 P: (630) 252-2442 (NBL PO) P: (630) 252-2767 (CRM sales) F: (630) 252-6256

  11. Terms of Reference for the International Partnership for the Hydrogen Economy

    Broader source: Energy.gov [DOE]

    Updated version (October 31, 2003) of the Terms of Reference for the International Partnership for the Hydrogen Economy, including purpose, functions, organization.

  12. Preliminary paper - Development of the Reference Design Description for a geologic repository

    SciTech Connect (OSTI)

    Daniel, Russell B.; Rindskopf, M. Sam

    1997-11-20

    This report describes the current Reference Design Description (RDD) design expectations for a potential geologic repository that could be located at Yucca Mountain in Nevada.

  13. Existing Commercial Reference Buildings Constructed In or After 1980 — Archive

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location.

  14. Zimbabwe-Terms of Reference for Future LEDS | Open Energy Information

    Open Energy Info (EERE)

    Jump to: navigation, search Name Zimbabwe-Terms of Reference for Future LEDS AgencyCompany Organization Climate and Development Knowledge Network (CDKN), United Kingdom...

  15. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Code Reference Manual

    SciTech Connect (OSTI)

    C. L. Smith; K. J. Kvarfordt; S. T. Wood

    2008-08-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE is funded by the U.S. Nuclear Regulatory Commission (NRC) and developed by the Idaho National Laboratory (INL). The INL's primary role in this project is that of software developer. However, the INL also plays an important role in technology transfer by interfacing and supporting SAPHIRE users comprised of a wide range of PRA practitioners from the NRC, national laboratories, the private sector, and foreign countries. SAPHIRE can be used to model a complex systems response to initiating events, quantify associated damage outcome frequencies, and identify important contributors to this damage (Level 1 PRA) and to analyze containment performance during a severe accident and quantify radioactive releases (Level 2 PRA). It can be used for a PRA evaluating a variety of operating conditions, for example, for a nuclear reactor at full power, low power, or at shutdown conditions. Furthermore, SAPHIRE can be used to analyze both internal and external initiating events and has special features for transforming models built for internal event analysis to models for external event analysis. It can also be used in a limited manner to quantify risk in terms of release consequences to both the public and the environment (Level 3 PRA). SAPHIRE includes a separate module called the Graphical Evaluation Module (GEM). GEM provides a highly specialized user interface with SAPHIRE that automates SAPHIRE process steps for evaluating operational events at commercial nuclear power plants. Using GEM, an analyst can estimate the risk associated with operational events in a very efficient and expeditious manner. This reference guide will introduce the SAPHIRE Version 7.0 software. A brief discussion of the purpose and history of the software is included along with general information such as installation instructions, starting and stopping the program, and some pointers on how to get around inside the program. Next, database concepts and structure are discussed. Following that discussion are nine sections, one for each of the menu options on the SAPHIRE main menu, wherein the purpose and general capabilities for each option are furnished. Next, the capabilities and limitations of the software are provided.

  16. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Code Reference Manual

    SciTech Connect (OSTI)

    C. L. Smith; K. J. Kvarfordt; S. T. Wood

    2006-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE is funded by the U.S. Nuclear Regulatory Commission (NRC) and developed by the Idaho National Laboratory (INL). The INL's primary role in this project is that of software developer. However, the INL also plays an important role in technology transfer by interfacing and supporting SAPHIRE users comprised of a wide range of PRA practitioners from the NRC, national laboratories, the private sector, and foreign countries. SAPHIRE can be used to model a complex systems response to initiating events, quantify associated damage outcome frequencies, and identify important contributors to this damage (Level 1 PRA) and to analyze containment performance during a severe accident and quantify radioactive releases (Level 2 PRA). It can be used for a PRA evaluating a variety of operating conditions, for example, for a nuclear reactor at full power, low power, or at shutdown conditions. Furthermore, SAPHIRE can be used to analyze both internal and external initiating events and has special features for ansforming models built for internal event analysis to models for external event analysis. It can also be used in a limited manner to quantify risk in terms of release consequences to both the public and the environment (Level 3 PRA). SAPHIRE includes a separate module called the Graphical Evaluation Module (GEM). GEM provides a highly specialized user interface with SAPHIRE that automates SAPHIRE process steps for evaluating operational events at commercial nuclear power plants. Using GEM, an analyst can estimate the risk associated with operational events in a very efficient and expeditious manner. This reference guide will introduce the SAPHIRE Version 7.0 software. A brief discussion of the purpose and history of the software is included along with general information such as installation instructions, starting and stopping the program, and some pointers on how to get around inside the program. Next, database concepts and structure are discussed. Following that discussion are nine sections, one for each of the menu options on the SAPHIRE main menu, wherein the purpose and general capabilities for each option are furnished. Next, the capabilities and limitations of the software are provided.

  17. Lithium Ethylene Dicarbonate Identified as the Primary Product...

    Office of Scientific and Technical Information (OSTI)

    Lithium Ethylene Dicarbonate Identified as the Primary Product ofChemical and Electrochemical Reduction of EC in EC:EMC1.2M LiPF6Electrolyte Citation Details In-Document Search ...

  18. Is Primary Prostate Cancer Treatment Influenced by Likelihood of

    Office of Scientific and Technical Information (OSTI)

    Extraprostatic Disease? A Surveillance, Epidemiology and End Results Patterns of Care Study (Journal Article) | SciTech Connect Is Primary Prostate Cancer Treatment Influenced by Likelihood of Extraprostatic Disease? A Surveillance, Epidemiology and End Results Patterns of Care Study Citation Details In-Document Search Title: Is Primary Prostate Cancer Treatment Influenced by Likelihood of Extraprostatic Disease? A Surveillance, Epidemiology and End Results Patterns of Care Study Purpose: To

  19. Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance

    SciTech Connect (OSTI)

    Dunn, L.; Gostein, M.; Emery, K.

    2012-09-01

    As the photovoltaics (PV) industry has grown, the need for accurately monitoring the solar resource of PV power plants has increased. Historically, the PV industry has relied on thermopile pyranometers for irradiance measurements, and a large body of historical irradiance data taken with pyranometers exists. However, interest in PV reference devices is increasing. In this paper, we discuss why PV reference devices are better suited for PV applications, and estimate the typical uncertainties in irradiance measurements made with both pyranometers and PV reference devices. We assert that the quantity of interest in monitoring a PV power plant is the equivalent irradiance under the IEC 60904-3 reference solar spectrum that would produce the same electrical response in the PV array as the incident solar radiation. For PV-plant monitoring applications, we find the uncertainties in irradiance measurements of this type to be on the order of +/-5% for thermopile pyranometers and +/-2.4% for PV reference devices.

  20. Characterization of the Defense Waste Processing Facility (DWPF) Environmental Assessment (EA) glass Standard Reference Material. Revision 1

    SciTech Connect (OSTI)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Crawford, C.L.; Pickett, M.A.

    1993-06-01

    Liquid high-level nuclear waste at the Savannah River Site (SRS) will be immobilized by vitrification in borosilicate glass. The glass will be produced and poured into stainless steel canisters in the Defense Waste Processing Facility (DWPF). Other waste form producers, such as West Valley Nuclear Services (WVNS) and the Hanford Waste Vitrification Project (HWVP), will also immobilize high-level radioactive waste in borosilicate glass. The canistered waste will be stored temporarily at each facility for eventual permanent disposal in a geologic repository. The Department of Energy has defined a set of requirements for the canistered waste forms, the Waste Acceptance Product Specifications (WAPS). The current Waste Acceptance Primary Specification (WAPS) 1.3, the product consistency specification, requires the waste form producers to demonstrate control of the consistency of the final waste form using a crushed glass durability test, the Product Consistency Test (PCI). In order to be acceptable, a waste glass must be more durable during PCT analysis than the waste glass identified in the DWPF Environmental Assessment (EA). In order to supply all the waste form producers with the same standard benchmark glass, 1000 pounds of the EA glass was fabricated. The chemical analyses and characterization of the benchmark EA glass are reported. This material is now available to act as a durability and/or redox Standard Reference Material (SRM) for all waste form producers.

  1. Water quality: Historic values and impact of drilling activities during FY 1988 at the reference repository location in southeastern Washington

    SciTech Connect (OSTI)

    Eddy, P.A.; Teel, S.S.; Raymond, J.R.; Bierschenk, W.H.

    1988-03-01

    The purpose of the Environmental Monitoring Program was to monitor the characterization activities related to the Basalt Waste Isolation Project (BWIP) at boreholes DC-24CX and DC-25CX and document any environmental impacts as a result of these activities including contamination and/or degradation of the aquifer water quality from the invasion of drilling fluids into the formation and surface contamination from the disposal of drilling fluid at the land surface. The first phase of this program involved describing the baseline water quality at the Reference Repository Location (RRL) including data for spring and surface waters, and both the unconfined and confined aquifers. The second phase involved the collection and analysis of samples collected during drilling operations at wells DC-24CX and DC-25CX. Five surface water and 25 spring sampling sites were designated for chemical and radiological background data collection for BWIP. Chemical and radiological background data from 61 wells that obtain water from the unconfined aquifers indicate that the chemistry of these aquifers is similar to the spring and surface water samples. However, some of the wells show contamination from existing operations and past operations of various facilities on the Hanford Site. These contaminants are both chemical and radiological in nature with nitrate as the primary chemical constituent and tritium as the major radiological constituent. 20 refs., 9 figs., 8 tabs.

  2. Fracture mechanics evaluation for at typical PWR primary coolant pipe

    SciTech Connect (OSTI)

    Tanaka, T.; Shimizu, S.; Ogata, Y.

    1997-04-01

    For the primary coolant piping of PWRs in Japan, cast duplex stainless steel which is excellent in terms of strength, corrosion resistance, and weldability has conventionally been used. The cast duplex stainless steel contains the ferrite phase in the austenite matrix and thermal aging after long term service is known to change its material characteristics. It is considered appropriate to apply the methodology of elastic plastic fracture mechanics for an evaluation of the integrity of the primary coolant piping after thermal aging. Therefore we evaluated the integrity of the primary coolant piping for an initial PWR plant in Japan by means of elastic plastic fracture mechanics. The evaluation results show that the crack will not grow into an unstable fracture and the integrity of the piping will be secured, even when such through wall crack length is assumed to equal the fatigue crack growth length for a service period of up to 60 years.

  3. Design study of primary ion provider for RHIC-EBIS

    SciTech Connect (OSTI)

    Kondo, K.; Kanesue, T.; Tamura, J.; Okamura, M.

    2009-09-20

    Brookhaven National Laboratory (BNL) has developed the new pre-injector system, Electron Beam Ion Source (EBIS) for Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

  4. A Wide Temperature, Radiation Tolerant, CMOS-compatible Precision Voltage Reference for Extreme Environment Instrumentation Systems

    SciTech Connect (OSTI)

    McCue, Mr. Benjamin; Blalock, Benjamin; Potts, J.; Kemerling, Mr. James; Isihara, Mr. Kyoshi; Leines, Capt. Matt; Britton Jr, Charles L

    2013-01-01

    Many design techniques have been incorporated into modern CMOS design practices to improve radiation tolerance of integrated circuits. Annular-gate NMOS structures have been proven to be significantly more radiation tolerant than the standard straight-gate variety. Many circuits can be designed using the annular-gate NMOS and the inherently radiation tolerant PMOS. Band-gap reference circuits, however, typically require p-n junction diodes. These p-n junction diodes are the dominating factor in radiation degradation in band-gap reference circuits. This paper proposes a different approach to band-gap reference design to alleviate the radiation susceptibility presented by the p-n junction diodes.

  5. Uranium Certified Reference Materials Price List | U.S. DOE Office of

    Office of Science (SC) Website

    Science (SC) Uranium Certified Reference Materials Price List NBL Program Office NBL PO Home About Programs Certified Reference Materials (CRMs) Prices and Certificates Ordering Information NEPA Documents News Safety Data Sheets (SDS) for NBL Program Office Certified Reference Materials (CRM) Contact Information NBL Program Office U.S. Department of Energy Building 201 9800 South Cass Avenue Argonne, IL 60439-4899 P: (630) 252-2442 (NBL PO) P: (630) 252-2767 (CRM sales) F: (630) 252-6256 E:

  6. Safety and performance enhancement circuit for primary explosive detonators

    DOE Patents [OSTI]

    Davis, Ronald W.

    2006-04-04

    A safety and performance enhancement arrangement for primary explosive detonators. This arrangement involves a circuit containing an energy storage capacitor and preset self-trigger to protect the primary explosive detonator from electrostatic discharge (ESD). The circuit does not discharge into the detonator until a sufficient level of charge is acquired on the capacitor. The circuit parameters are designed so that normal ESD environments cannot charge the protection circuit to a level to achieve discharge. When functioned, the performance of the detonator is also improved because of the close coupling of the stored energy.

  7. Primary Cilium-Dependent and -Independent Hedgehog Signaling Inhibits

    Office of Scientific and Technical Information (OSTI)

    p16INK4A (Journal Article) | SciTech Connect Journal Article: Primary Cilium-Dependent and -Independent Hedgehog Signaling Inhibits p16INK4A Citation Details In-Document Search Title: Primary Cilium-Dependent and -Independent Hedgehog Signaling Inhibits p16INK4A Authors: Bishop, Cleo L. ; Bergin, Ann-Marie H. ; Fessart, Delphine ; Borgdorff, Viola ; Hatzimasoura, Elizabeth ; Garbe, James C. ; Stampfer, Martha R. ; Koh, Jim ; Beach, David H. Publication Date: 2010-11-01 OSTI Identifier:

  8. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    home page NERSC science requirements workshop page NERSC science requirements case study FAQ Workshop Agenda Previous NERSC Requirements Workshops Biological and...

  9. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    home page NERSC science requirements workshop page NERSC science requirements case study FAQ Previous NERSC Requirements Workshops Biological and Environmental Research...

  10. Reference Documents

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Study Assumptions NOS 2009 PTSA Exhibit B Requesting a Cluster Study Report Posted 2009 Network Open Season Cluster Study Presentation PTSA Summary by Customer PTSA Summary by...

  11. Reference Documents

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Projects Expand Projects Skip navigation links Ancillary and Control Area Services (ACS) Practices Forum Attachment K Commercial Business Process Improvement (CBPI) Customer...

  12. Reference Documents

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    | Contact | Investors | bpa.gov Search Doing Business Expand Doing Business Customer Involvement Expand Customer Involvement Reports & Tools Expand Reports & Tools Operations &...

  13. Reference Shelf

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of Women in Science Biography.com Marquis Who's Who NobelPrize.org Nobel Prize Internet Archive Calculators OnlineConversion.com Wolfram|Alpha Computational Knowledge Engine...

  14. X-ray Moiré deflectometry using synthetic reference images

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Stutman, Dan; Valdivia, Maria Pia; Finkenthal, Michael

    2015-06-25

    Moiré fringe deflectometry with grating interferometers is a technique that enables refraction-based x-ray imaging using a single exposure of an object. To obtain the refraction image, the method requires a reference fringe pattern (without the object). Our study shows that, in order to avoid artifacts, the reference pattern must be exactly matched in phase with the object fringe pattern. In experiments, however, it is difficult to produce a perfectly matched reference pattern due to unavoidable interferometer drifts. We present a simple method to obtain matched reference patterns using a phase-scan procedure to generate synthetic Moiré images. As a result, themore » method will enable deflectometric diagnostics of transient phenomena such as laser-produced plasmas and could improve the sensitivity and accuracy of medical phase-contrast imaging.« less

  15. Generic TriBITS PRoject, Build, Test, and Install Quick Reference...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Test, and Install Quick Reference Guide Ross Bartlett Oak Ridge National Laboratory CASL-U-2014-0075-000-a CASL-U-2014-0075-000-a Generic TriBITS PRoject, Build, Test, and ...

  16. File:East China Map Reference.pdf | Open Energy Information

    Open Energy Info (EERE)

    pixels, file size: 640 KB, MIME type: applicationpdf) Reference map for wind power density maps at 50 m above ground and 1km resolution for eastern China from NREL Description...

  17. Tables of cross references among SECY 82-111, NUREG 0700, NUREG 0835, NUREG 0801

    SciTech Connect (OSTI)

    Savage, J.W.

    1982-03-10

    This memorandum cross references topical statements extracted from four NRC documents that are useful for guidance in reviewing the Human Factors Engineering designs of main control rooms and control centers outside the main control rooms.

  18. DOE Refers Two ENERGY STAR Models to EPA for Potential De-Listing...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Two ENERGY STAR Models to EPA for Potential De-Listing DOE Refers Two ENERGY STAR Models to EPA for Potential De-Listing January 11, 2012 - 11:00am Addthis U.S. Department of...

  19. Reference module selection criteria for accurate testing of photovoltaic (PV) panels

    SciTech Connect (OSTI)

    Roy, J.N.; Gariki, Govardhan Rao; Nagalakhsmi, V.

    2010-01-15

    It is shown that for accurate testing of PV panels the correct selection of reference modules is important. A detailed description of the test methodology is given. Three different types of reference modules, having different I{sub SC} (short circuit current) and power (in Wp) have been used for this study. These reference modules have been calibrated from NREL. It has been found that for accurate testing, both I{sub SC} and power of the reference module must be either similar or exceed to that of modules under test. In case corresponding values of the test modules are less than a particular limit, the measurements may not be accurate. The experimental results obtained have been modeled by using simple equivalent circuit model and associated I-V equations. (author)

  20. Generic TriBITS Project, Build, Test, and Install Reference Guide

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Generic TriBITS Project, Build, Test, and Install Reference Guide Author: Roscoe A. Bartlett Contact: bartlett.roscoe@gmail.com Date: 2015-08-27 Version: tribitsstart-1317-g4908e4...

  1. NIF Functional Requirements and Primary Criteria Rev. 1.8 September...

    Office of Scientific and Technical Information (OSTI)

    Technical Report: NIF Functional Requirements and Primary Criteria Rev. 1.8 September 2006 Citation Details In-Document Search Title: NIF Functional Requirements and Primary ...

  2. A time-dependent formulation of multi-reference perturbation theory

    Office of Scientific and Technical Information (OSTI)

    (Journal Article) | SciTech Connect A time-dependent formulation of multi-reference perturbation theory Citation Details In-Document Search This content will become publicly available on February 10, 2017 Title: A time-dependent formulation of multi-reference perturbation theory Authors: Sokolov, Alexander Yu. [1] ; Chan, Garnet Kin-Lic [1] + Show Author Affiliations Department of Chemistry, Princeton University, Princeton, New Jersey 08544, USA Publication Date: 2016-02-14 OSTI Identifier:

  3. Environmental Guidance Program reference book: Toxic substances control act. Revision 7

    SciTech Connect (OSTI)

    1994-12-01

    This Reference Book contains a current copy of the Toxic Substances Control Act and those regulations that implement the statute and appear to be most relevant to DOE activities. The document is provided to DOE staff for informational purposes only and should not be interpreted as legal guidance. Questions concerning this Reference Book may be directed to Mark Petts, EH-231 (202/586-2609).

  4. Toxic Substances Control Act. Environmental Guidance Program Reference Book: Revision 6

    SciTech Connect (OSTI)

    Not Available

    1992-05-15

    This Reference Book contains a current copy of the Toxic Substances Control Act and those regulations that implement the statute and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Questions concerning this Reference Book may be directed to Mark Petts, EH-231 (202/586-2609).

  5. H2FIRST Reference Station Design Task: Project Deliverable 2-2 | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy Reference Station Design Task: Project Deliverable 2-2 H2FIRST Reference Station Design Task: Project Deliverable 2-2 This H2FIRST project report, published in April 2015, presents near-term station cost results and discusses cost trends of different station types. It compares various vehicle rollout scenarios and projects realistic near-term station utilization values using the station infrastructure rollout in California as an example. It describes near-term market demands and

  6. Technology, safety and costs of decommissioning a reference boiling water reactor power station. Appendices. Volume 2

    SciTech Connect (OSTI)

    Oak, H.D.; Holter, G.M.; Kennedy, W.E. Jr.; Konzek, G.J.

    1980-06-01

    Appendices are presented concerning the evaluations of decommissioning financing alternatives; reference site description; reference BWR facility description; radiation dose rate and concrete surface contamination data; radionuclide inventories; public radiation dose models and calculated maximum annual doses; decommissioning methods; generic decommissioning information; immediate dismantlement details; passive safe storage, continuing care, and deferred dismantlement details; entombment details; demolition and site restoration details; cost estimating bases; public radiological safety assessment details; and details of alternate study bases.

  7. Annual Energy Outlook Retrospective Review: Evaluation of 2014 and Prior Reference Case Projections

    U.S. Energy Information Administration (EIA) Indexed Site

    Annual Energy Outlook Retrospective Review: Evaluation of 2014 and Prior Reference Case Projections March 2015 Independent Statistics & Analysis www.eia.gov U.S. Department of Energy Washington, DC 20585 U.S. Energy Information Administration | AEO Retrospective Review: Evaluation of 2014 and Prior Reference Case Projections i This report was prepared by the U.S. Energy Information Administration (EIA), the statistical and analytical agency within the U.S. Department of Energy. By law, EIA's

  8. Clean Water Act (excluding Section 404). Environmental guidance program reference book: Revision 6

    SciTech Connect (OSTI)

    Not Available

    1993-01-15

    This Reference Book contains a current copy of the Clean Water Act (excluding Section 404) and those regulations that implement the statutes and appear to be most relevant to US Department of Energy (DOE) activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Updates that include important new requirements will be provided periodically. Questions concerning this Reference Book may be directed to Mark Petts, EH-231 (202/586-2609).

  9. Crack stability analysis of low alloy steel primary coolant pipe

    SciTech Connect (OSTI)

    Tanaka, T.; Kameyama, M.; Urabe, Y.

    1997-04-01

    At present, cast duplex stainless steel has been used for the primary coolant piping of PWRs in Japan and joints of dissimilar material have been applied for welding to reactor vessels and steam generators. For the primary coolant piping of the next APWR plants, application of low alloy steel that results in designing main loops with the same material is being studied. It means that there is no need to weld low alloy steel with stainless steel and that makes it possible to reduce the welding length. Attenuation of Ultra Sonic Wave Intensity is lower for low alloy steel than for stainless steel and they have advantageous inspection characteristics. In addition to that, the thermal expansion rate is smaller for low alloy steel than for stainless steel. In consideration of the above features of low alloy steel, the overall reliability of primary coolant piping is expected to be improved. Therefore, for the evaluation of crack stability of low alloy steel piping to be applied for primary loops, elastic-plastic future mechanics analysis was performed by means of a three-dimensioned FEM. The evaluation results for the low alloy steel pipings show that cracks will not grow into unstable fractures under maximum design load conditions, even when such a circumferential crack is assumed to be 6 times the size of the wall thickness.

  10. Table 9. Net electricity trade index and primary electricity...

    U.S. Energy Information Administration (EIA) Indexed Site

    2,2003,2004,2005,2006,2007,2008,2009,2010,,"Primary " ,,,2011,"Source" ,"Least CO2 per capita" ," New York",0.94,1,0.95,0.92,0.87,0.93,1.01,0.99,0.99,0.95,0.93,1,"Natural...

  11. Nuclear reference materials to meet the changing needs of the global nuclear community

    SciTech Connect (OSTI)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.; Oldham, R.D.; Mitchell, W.G.

    1995-12-31

    New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirements for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.

  12. Nuclear reference materials to meet the changing needs of the global nuclear community

    SciTech Connect (OSTI)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.; Oldham, R.D.

    1995-12-31

    New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.

  13. Cleaning Cesium Radionuclides from BN-350 Primary Sodium

    SciTech Connect (OSTI)

    Romanenko, O.G.; Allen, K.J.; Wachs, D.M.; Planchon, H.P.; Wells, P.B.; Michelbacher, J.A.; Nazarenko, P.; Dumchev, I.; Maev, V.; Zemtzev, B.; Tikhomirov, L.; Yakovlev, V.; Synkov, A

    2005-04-15

    This paper reports the successful design and operation of a system to remove highly radioactive cesium from the sodium coolant of the BN-350 reactor in Aktau, Kazakhstan. As an international effort between the United States and the Republic of Kazakhstan, a cesium-trapping system was jointly designed, fabricated, installed, and successfully operated. The results are significant for a number of reasons, including (a) a significant reduction of radioactivity levels of the BN-350 coolant and reactor surfaces, thereby reducing exposure to workers during shutdown operations; (b) demonstration of scientific ideas; and (c) the engineering application of effective cesium trap deployment for commercial-sized liquid-metal reactors. About 255 300 GBq (6900 Ci) of cesium was trapped, and the {sup 137}Cs specific activity in BN-350 primary sodium was decreased from 296 MBq/kg (8000 {mu}Ci/kg) to 0.37 MBq/kg (10 {mu}Ci/kg) by using seven cesium traps containing reticulated vitreous carbon (RVC) as the cesium adsorbent. Cesium trapping was accomplished by pumping sodium from the primary circuit, passing it through a block of RVC within each trap, and returning the cleaned sodium to the primary circuit. Both to predict and to analyze the behavior of the cesium traps in the BN-350 reactor primary circuit, a model was developed that satisfactorily describes the observed results of the cesium trapping. By using this model, thermodynamic parameters, such as the heat of adsorption of cesium atoms on RVC and on internal piping surfaces of the BN-350 reactor primary circuit, -22.7 and -5.0 kJ/mole, respectively, were extracted from the experimental data.

  14. Characterization of the resistance to PWSCC of hydraulic tube- tubesheet expansions. [Primary water stress corrosion cracking

    SciTech Connect (OSTI)

    Gold, R.E.; Economy, G.; Jacko, R.J.; Harrod, D.L.

    1992-07-01

    The resistance to primary water stress corrosion cracking (PWSCC) of hydraulically expanded Alloy 600 steam generator tubing, manufactured by the Westinghouse Specialty Metals Division, was evaluated under highly accelerated conditions in a 400{degrees}C steam test environment. These evaluations included microstructural characterizations of all test materials, screening tests with highly stressed reverse U-bends (RUBs), and the testing of internally pressurized hydraulic expansion tube-in-collar mockups. Eighteen heats of archived tubing from an operating nuclear power plant were evaluated; included were heats of Alloy 600 in both the mill annealed (A600 MA) and thermally treated (A600 TT) conditions. Other heats of archived A600 TT tubing, and reference laboratory heats with known corrosion resistance, were also included in various portions of this investigation. Hydraulically expanded mockups of A600 T-F tubing exhibit high resistance to PWSCC in the aggressive steam test environment. Some of the archived A600 MA heats, however, possess low resistance to PWSCC. Shot peening of the ID surfaces of tubes of these latter heats prior to testing was effective in precluding the occurrence of PWSCC. Archived heats of Model F (or F-type replacement) A600 TT steam generator tubing typically exhibit carbide morphologies and distributions consistent with high resistance to PWSCC. These data are in agreement with the performance to date of operating Model F steam generators.

  15. Scholarly context not found: One in five articles suffers from reference rot

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Klein, Martin; Van de Sompel, Herbert; Sanderson, Robert; Shankar, Harihar; Balakireva, Lyudmila; Zhou, Ke; Tobin, Richard; Bar-Ilan, Judit

    2014-12-26

    The emergence of the web has fundamentally affected most aspects of information communication, including scholarly communication. The immediacy that characterizes publishing information to the web, as well as accessing it, allows for a dramatic increase in the speed of dissemination of scholarly knowledge. But, the transition from a paper-based to a web-based scholarly communication system also poses challenges. In this paper, we focus on reference rot, the combination of link rot and content drift to which references to web resources included in Science, Technology, and Medicine (STM) articles are subject. We investigate the extent to which reference rot impacts themore » ability to revisit the web context that surrounds STM articles some time after their publication. We do so on the basis of a vast collection of articles from three corpora that span publication years 1997 to 2012. For over one million references to web resources extracted from over 3.5 million articles, we determine whether the HTTP URI is still responsive on the live web and whether web archives contain an archived snapshot representative of the state the referenced resource had at the time it was referenced. We observe that the fraction of articles containing references to web resources is growing steadily over time. We find one out of five STM articles suffering from reference rot, meaning it is impossible to revisit the web context that surrounds them some time after their publication. When only considering STM articles that contain references to web resources, this fraction increases to seven out of ten.« less

  16. Scholarly context not found: One in five articles suffers from reference rot

    SciTech Connect (OSTI)

    Klein, Martin; Van de Sompel, Herbert; Sanderson, Robert; Shankar, Harihar; Balakireva, Lyudmila; Zhou, Ke; Tobin, Richard; Bar-Ilan, Judit

    2014-12-26

    The emergence of the web has fundamentally affected most aspects of information communication, including scholarly communication. The immediacy that characterizes publishing information to the web, as well as accessing it, allows for a dramatic increase in the speed of dissemination of scholarly knowledge. But, the transition from a paper-based to a web-based scholarly communication system also poses challenges. In this paper, we focus on reference rot, the combination of link rot and content drift to which references to web resources included in Science, Technology, and Medicine (STM) articles are subject. We investigate the extent to which reference rot impacts the ability to revisit the web context that surrounds STM articles some time after their publication. We do so on the basis of a vast collection of articles from three corpora that span publication years 1997 to 2012. For over one million references to web resources extracted from over 3.5 million articles, we determine whether the HTTP URI is still responsive on the live web and whether web archives contain an archived snapshot representative of the state the referenced resource had at the time it was referenced. We observe that the fraction of articles containing references to web resources is growing steadily over time. We find one out of five STM articles suffering from reference rot, meaning it is impossible to revisit the web context that surrounds them some time after their publication. When only considering STM articles that contain references to web resources, this fraction increases to seven out of ten.

  17. EBR-II Primary Tank Wash-Water Alternatives Evaluation

    SciTech Connect (OSTI)

    Demmer, R. L.; Heintzelman, J. B.; Merservey, R. H.; Squires, L. N.

    2008-05-01

    The EBR-II reactor at Idaho National Laboratory was a liquid sodium metal cooled reactor that operated for 30 years. It was shut down in 1994; the fuel was removed by 1996; and the bulk of sodium metal coolant was removed from the reactor by 2001. Approximately 1100 kg of residual sodium remained in the primary system after draining the bulk sodium. To stabilize the remaining sodium, both the primary and secondary systems were treated with a purge of moist carbon dioxide. Most of the residual sodium reacted with the carbon dioxide and water vapor to form a passivation layer of primarily sodium bicarbonate. The passivation treatment was stopped in 2005 and the primary system is maintained under a blanket of dry carbon dioxide. Approximately 670 kg of sodium metal remains in the primary system in locations that were inaccessible to passivation treatment or in pools of sodium that were too deep for complete penetration of the passivation treatment. The EBR-II reactor was permitted by the Idaho Department of Environmental Quality (DEQ) in 2002 under a RCRA permit that requires removal of all remaining sodium in the primary and secondary systems by 2022. The proposed baseline closure method would remove the large components from the primary tank, fill the primary system with water, react the remaining sodium with the water and dissolve the reaction products in the wash water. This method would generate a minimum of 100,000 gallons of caustic, liquid, low level radioactive, hazardous waste water that must be disposed of in a permitted facility. On February 19-20, 2008, a workshop was held in Idaho Falls, Idaho, to look at alternatives that could meet the RCRA permit clean closure requirements and minimize the quantity of hazardous waste generated by the cleanup process. The workshop convened a panel of national and international sodium cleanup specialists, subject matter experts from the INL, and the EBR-II Wash Water Project team that organized the workshop. The workshop was conducted by a trained facilitator using Value Engineering techniques to elicit the most technically sound solutions from the workshop participants. The path forward includes developing the OBA into a well engineered solution for achieving RCRA clean closure of the EBR-II Primary Reactor Tank system. Several high level tasks are also part of the path forward such as reassigning responsibility of the cleanup project to a dedicated project team that is funded by the DOE Office of Environmental Management, and making it a priority so that adequate funding is available to complete the project. Based on the experience of the sodium cleanup specialists, negotiations with the DEQ will be necessary to determine a risk-based de minimus quantity for acceptable amount of sodium that can be left in the reactor systems after cleanup has been completed.

  18. Mechanical Design of the HER Synchrotron Light Monitor Primary Mirror

    SciTech Connect (OSTI)

    Daly, Edward F.; Fisher, Alan S.; Kurita, Nadine R.; Langton, J.; /SLAC

    2011-09-14

    This paper describes the mechanical design of the primary mirror that images the visible portion of the synchrotron radiation (SR) extracted from the High Energy Ring (HER) of the PEP-II B-Factory. During off-axis operation, the water-cooled GlidCop mirror is subjected to a heat flux in excess of 2000 W/cm2. When on-axis imaging occurs, the heat flux due to scattered SR, resistive wall losses and Higher-Order-Mode (HOM) heating is estimated at 1 W/cm2. The imaging surface is plated with Electroless Nickel to improve its optical characteristics. The design requirements for the primary mirror are listed and discussed. Calculated mechanical distortions and stresses experienced by the mirror during on-axis and off-axis operation will be presented.

  19. DETECTION OF THE COMPRESSED PRIMARY STELLAR WIND IN {eta} CARINAE

    SciTech Connect (OSTI)

    Teodoro, M.; Madura, T. I.; Gull, T. R.; Corcoran, M. F.; Hamaguchi, K.

    2013-08-10

    A series of three Hubble Space Telescope/Space Telescope Imaging Spectrograph spectroscopic mappings, spaced approximately one year apart, reveal three partial arcs in [Fe II] and [Ni II] emissions moving outward from {eta} Carinae. We identify these arcs with the shell-like structures, seen in the three-dimensional hydrodynamical simulations, formed by compression of the primary wind by the secondary wind during periastron passages.

  20. Comparing the Primary Electron Transfer Process in Organic Photovoltaic

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Heterojunctions with Photosynthetic Reaction Centers | MIT-Harvard Center for Excitonics Comparing the Primary Electron Transfer Process in Organic Photovoltaic Heterojunctions with Photosynthetic Reaction Centers October 4, 2011 at 3pm/36-428 Garry Rumbles National Renewable Energy Laboratory (NREL), Univeristy of Colorado, Boulder rumbles002 Abstract: This presentation will focus on some of the fundamental science associated with the rapidly emerging field of organic photovoltaics (OPV).