Powered by Deep Web Technologies
Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Repository Reference Disposal Concepts and Thermal Load Management...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Repository Reference Disposal Concepts and Thermal Load Management Analysis Repository Reference Disposal Concepts and Thermal Load Management Analysis A disposal concept consists...

2

Repository Reference Disposal Concepts and Thermal Load Management Analysis  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Repository Reference Disposal Concepts and Thermal Load Management Repository Reference Disposal Concepts and Thermal Load Management Analysis Repository Reference Disposal Concepts and Thermal Load Management Analysis A disposal concept consists of three parts: waste inventory (7 waste types examined), geologic setting (e.g., clay/shale, salt, crystalline, other sedimentary), and the engineering concept of operations (range of generic operational concepts examined). Two major categories for waste package emplacement modes are identified: 1) "open" where extended ventilation can remove heat for many years following waste emplacement underground; and 2) "enclosed" modes for clay/shale and salt media where waste packages are emplaced in direct or close contact with natural or engineered materials which may have temperature limits that constrain thermal

3

Repository Reference Disposal Concepts and Thermal Load Management Analysis  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Repository Reference Disposal Concepts and Thermal Load Management Repository Reference Disposal Concepts and Thermal Load Management Analysis Repository Reference Disposal Concepts and Thermal Load Management Analysis A disposal concept consists of three parts: waste inventory (7 waste types examined), geologic setting (e.g., clay/shale, salt, crystalline, other sedimentary), and the engineering concept of operations (range of generic operational concepts examined). Two major categories for waste package emplacement modes are identified: 1) "open" where extended ventilation can remove heat for many years following waste emplacement underground; and 2) "enclosed" modes for clay/shale and salt media where waste packages are emplaced in direct or close contact with natural or engineered materials which may have temperature limits that constrain thermal

4

A Liquid-Helium-Cooled Absolute Reference Cold Load forLong-Wavelength Radiometric Calibration  

SciTech Connect

We describe a large (78-cm) diameter liquid-helium-cooled black-body absolute reference cold load for the calibration of microwave radiometers. The load provides an absolute calibration near the liquid helium (LHe) boiling point, accurate to better than 30 mK for wavelengths from 2.5 to 25 cm (12-1.2 GHz). The emission (from non-LHe temperature parts of the cold load) and reflection are small and well determined. Total corrections to the LHe boiling point temperature are {le} 50 mK over the operating range. This cold load has been used at several wavelengths at the South Pole and at the White Mountain Research Station. In operation, the average LHe loss rate was {le} 4.4 l/hr. Design considerations, radiometric and thermal performance and operational aspects are discussed. A comparison with other LHe-cooled reference loads including the predecessor of this cold load is given.

Bensadoun, M.; Witebsky, C.; Smoot, George F.; De Amici,Giovanni; Kogut, A.; Levin, S.

1990-05-01T23:59:59.000Z

5

Reference:  

E-Print Network (OSTI)

Operator Corporation (CAISO), revised tariff sheets to define the circumstances under which Metered Subsystem resources can use its Reliability Must Run (RMR) units for load following purposes. 1 Specifically, the CAISO revised Section 4.9.13.2 (Load-Following or Non Load-Following Election) of the MRTU Tariff to reflect that an MSS Operator may designate RMR units as load following, and that load following RMR units must be available to the CAISO for dispatch up to the maximum net dependable capacity specified in the RMR contract. The CAISO tariff provides that if the CAISO does not dispatch an RMR load following resource for local reliability needs, the MSS Operator will have the opportunity to participate in the CAISO markets as any other non-RMR load following unit subject to Section 30.5.2.5 (Supply Bids for Metered Subsystems). The revised tariff sheets are accepted for filing to become effective upon implementation of MRTU. 2 1 Load following is typically defined as the use of generation to meet the hour-tohour and daily variations in system load. 2 On March 26, 2008, the Commission issued an order granting the CAISO’s motion to modify the effective date of the MRTU Tariff based on a representation that due to delays in the implementation of MRTU, the March 31, 2008 effective20080612-3013 FERC PDF (Unofficial) 06/12/2008 Docket No. ER06-615-014-2-This filing was noticed on October 10, 2007, with comments, protests, or motions

Bird Llp; Bradley R. Miliauskas

2008-01-01T23:59:59.000Z

6

1-GWh diurnal load-leveling Superconducting Magnetic Energy Storage system reference design  

DOE Green Energy (OSTI)

A point reference design has been completed for a 1-GWh Superconducting Magnetic Energy Storage system. The system is for electric utility diurnal load-leveling but can also function to meet much faster power demands including dynamic stabilization. This study explores several concepts of design not previously considered in the same detail as treated here. Because the study is for a point design, optimization in all respects is not complete. This report examines aspects of the coil, the superconductor supported off of the dewar shell, the dewar shell, and its configuration and stresses, the underground excavation and construction for holding the superconducting coil and its dewar, the helium refrigeration system, the electrical converter system, the vacuum system, the guard coil, and the costs. This report is divided into two major portions. The first is a general treatment of the work and the second is seven detailed technical appendices issued as separate reports. The information presented on the aluminum stabilizer for the conductor, on the excavation, and on the converter is based upon industrial studies contracted for this work.

Rogers, J.D.; Hassenzahl, W.V.; Schermer, R.I. (comps.)

1979-09-01T23:59:59.000Z

7

References  

NLE Websites -- All DOE Office Websites (Extended Search)

Analysis Analysis Analysis - Home Analytical Dashboards Computerized Accident Incident Reporting and Recordkeeping System (CAIRS) Corporate Safety Analysis Trends Daily Occurrence Reports Electrical Safety Occurrences Final Occurrence Reports Access System Login Lessons Learned and Best Practices Occurrence Reporting and Processing System (ORPS) Operating Experience Committee Operating Experience Level 1, 2, and 3 Documents Operating Experience Summaries Radiation Exposure Monitoring Systems (REMS) Safety Bulletins Safety and Health Alerts Safety Basis Information System (SBIS) Suspect/Counterfeit Items and Defective Items (SCI/DI) References HSS Logo References DOE O 210.2A, DOE Corporate Operating Experience Program (Apr 08, 2011) DOE O 210.2 Crosswalk DOE O 231.1B, Environment, Safety and Health Reporting (Jun 27, 2011)

8

REFERENCES  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

205.1B 205.1B Approved 05-16-2011 Page 1 REFERENCES 1. INTRODUCTION 2. . Includes a list of sources cited in the directive and additional information sources to assist in implementing DOE Order 205.1B, Cyber Security Program. FEDERAL LAWS AND REGULATIONS a. Public Law (P.L.) 93-579, Privacy Act of 1974, as amended [Title 5 United States Code (U.S.C.) Section 552a]. . b. P.L. 104-106, Division E, Clinger Cohen Act (CCA) (formerly Information Technology Management Reform Act of 1996. c. P.L. 106-65, "National Defense Authorization Act [Section 3212(d)], enacted October 1999. d. P.L. 107-347, Title III, Federal Information Security Management Act of 2002 (FISMA), enacted December 2002. 3. OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULARS. Located at http://www.whitehouse.gov/omb/circulars_default/.

9

1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design. Appendix A: energy storage coil and superconductor  

DOE Green Energy (OSTI)

The technical aspects of a 1-GWh Superconducting Magnetic Energy Storage (SMES) coil for use as a diurnal load-leveling device in an electric utility system are presented. The superconductor for the coil is analyzed, and costs for the entire coil are developed.

Schermer, R.I.

1979-09-01T23:59:59.000Z

10

Reference design of 100 MW-h lithium/iron sulfide battery system for utility load leveling  

SciTech Connect

The first year in a two-year cooperative effort between Argonne National Laboratory and Rockwell International to develop a conceptual design of a lithium alloy/iron sulfide battery for utility load leveling is presented. A conceptual design was developed for a 100 MW-h battery system based upon a parallel-series arrangement of 2.5 kW-h capacity cells. The sales price of such a battery system was estimated to be very high, $80.25/kW-h, exclusive of the cost of the individual cells, the dc-to-ac converters, site preparation, or land acquisition costs. Consequently, the second year's efforts were directed towards developing modified designs with significantly lower potential costs.

Zivi, S.M.; Kacinskas, H.; Pollack, I.; Chilenskas, A.A.; Barney, D.L.; Grieve, W.; McFarland, B.L.; Sudar, S.; Goldstein, E.; Adler, E.

1980-03-01T23:59:59.000Z

11

reference | OpenEI Community  

Open Energy Info (EERE)

98 98 Varnish cache server Home Groups Community Central Green Button Applications Developer Utility Rate FRED: FRee Energy Database More Public Groups Private Groups Features Groups Blog posts Content Stream Documents Discussions Polls Q & A Events Notices My stuff Energy blogs 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142235098 Varnish cache server reference Home Jweers's picture Submitted by Jweers(83) Contributor 7 August, 2013 - 18:23 New Robust References! citation citing developer formatting reference Semantic Mediawiki wiki Check out the new Reference Form. Adding a reference object to OpenEI using this form is the most complete way to cite a reference. After providing the name of your reference, the form will ask for your document

12

load | OpenEI  

Open Energy Info (EERE)

load load Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (9 months ago) Date Updated July 02nd, 2013 (7 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

13

References - CECM  

E-Print Network (OSTI)

help · annotate · Contents Next: About this document Up: RamanujanModular Equations, Previous: Sources · [Annotate] · [Shownotes]. References.

14

Reference Tools  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Tools Current Greenhouse Gas Concentrations Name that compound: The numbers game for CFCs, HFCs, HCFCs, and Halons Conversion Tables and More Glossary Acronyms CDIAC's...

15

Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Shelf Reference Shelf Reference Shelf Find reference sources Questions? 505-667-5809 Email Biography Biographies of Women in Science Biography.com Marquis Who's Who NobelPrize.org Nobel Prize Internet Archive Calculators Currency Converter OnlineConversion.com Wolfram|Alpha Computational Knowledge Engine Dictionaries Oxford English Dictionary Merriam-Webster Dictionary DOD Dictionary of Military Terms Encyclopedias Britannica Online Columbia Encyclopedia Wikipedia Grants & Funding DOE Office of Science Grants & Contracts National Science Foundation National Institutes of Health Grants.Gov FedBizOpps.gov Los Alamos Info Los Alamos County Los Alamos Historical Society University of New Mexico - Los Alamos Campus Maps Atlapedia Online Perry-Casteneda Library Map Collection U.S. Gazetteer

16

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs, each directly proportional to one of the six general load components. 16 figs.

Spletzer, B.L.

1998-12-15T23:59:59.000Z

17

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs which can be combined to determine any one of the six general load components.

Spletzer, Barry L. (Albuquerque, NM)

2001-01-01T23:59:59.000Z

18

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs, each directly proportional to one of the six general load components.

Spletzer, Barry L. (Albuquerque, NM)

1998-01-01T23:59:59.000Z

19

STANDARD REFERENCE  

E-Print Network (OSTI)

The profession is strongly urged to use the standard reference on the financial framework in the EU, concerning endorsed IFRS in order to give a clear message to the market and to users of financial statements in and outside the EU.

unknown authors

2005-01-01T23:59:59.000Z

20

Subject: References:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Subject: Subject: References: DEAR 970.3102-2 Compensation for personal services DEAR 970.5204-13 Allowable costs and fixed-fee (Management and operating contracts) DEAR 970.5204-14 Allowable costs and fixed-fee (support contracts) When is this ~\.cquisition Letter (AL) Effective? This AL is effective 10 days from the date of issuance. This gui~ce supersedes any previous statutory cap on executive compensation. Existing contracts need to be reviewed to determine whether contract terms and conditions are consistent with the guidance in this AL, or whether contract modifications are necessary. When Does this AL Expire? This AL remain;; in effect until superseded or canceled. Whom do you Contact for More Information? Contact the Office of Procurement and Assistance Policy, for questions pertaining to the

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

building load | OpenEI  

Open Energy Info (EERE)

load load Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (9 months ago) Date Updated July 02nd, 2013 (7 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

22

Load Control  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Visualization and Controls Peer Review Visualization and Controls Peer Review Load Control for System Reliability and Measurement-Based Stability Assessment Dan Trudnowski, PhD, PE Montana Tech Butte, MT 59701 dtrudnowski@mtech.edu 406-496-4681 October 2006 2 Presentation Outline * Introduction - Goals, Enabling technologies, Overview * Load Control - Activities, Status * Stability Assessment - Activities, Status * Wrap up - Related activities, Staff 3 Goals * Research and develop technologies to improve T&D reliability * Technologies - Real-time load control methodologies - Measurement-based stability-assessment 4 Enabling Technologies * Load control enabled by GridWise technology (e.g. PNNL's GridFriendly appliance) * Real-time stability assessment enabled by Phasor Measurement (PMU) technology 5 Project Overview * Time line: April 18, 2006 thru April 17, 2008

23

NEWTON's Chemistry References  

NLE Websites -- All DOE Office Websites (Extended Search)

Chemistry References Do you have a great chemistry reference link? Please click our Ideas page. Featured Reference Links: Steve Marsden's Chemistry Resources Steve Marsden's...

24

NEWTON's Physics References  

NLE Websites -- All DOE Office Websites (Extended Search)

Physics References Do you have a great physics reference link? Please click our Ideas page. Featured Reference Links: Physics Links Physics Links from AAPT See the American...

25

2005 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE  

U.S. Energy Information Administration (EIA)

2010 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE. Kerosene. ... • Geothermal energy drilling company • Logging company •Privately owned port or loading dock

26

Coal data: A reference  

SciTech Connect

This report, Coal Data: A Reference, summarizes basic information on the mining and use of coal, an important source of energy in the US. This report is written for a general audience. The goal is to cover basic material and strike a reasonable compromise between overly generalized statements and detailed analyses. The section ``Supplemental Figures and Tables`` contains statistics, graphs, maps, and other illustrations that show trends, patterns, geographic locations, and similar coal-related information. The section ``Coal Terminology and Related Information`` provides additional information about terms mentioned in the text and introduces some new terms. The last edition of Coal Data: A Reference was published in 1991. The present edition contains updated data as well as expanded reviews and additional information. Added to the text are discussions of coal quality, coal prices, unions, and strikes. The appendix has been expanded to provide statistics on a variety of additional topics, such as: trends in coal production and royalties from Federal and Indian coal leases, hours worked and earnings for coal mine employment, railroad coal shipments and revenues, waterborne coal traffic, coal export loading terminals, utility coal combustion byproducts, and trace elements in coal. The information in this report has been gleaned mainly from the sources in the bibliography. The reader interested in going beyond the scope of this report should consult these sources. The statistics are largely from reports published by the Energy Information Administration.

Not Available

1995-02-01T23:59:59.000Z

27

LOADING DEVICE  

DOE Patents (OSTI)

A device is presented for loading or charging bodies of fissionable material into a reactor. This device consists of a car, mounted on tracks, into which the fissionable materials may be placed at a remote area, transported to the reactor, and inserted without danger to the operating personnel. The car has mounted on it a heavily shielded magazine for holding a number of the radioactive bodies. The magazine is of a U-shaped configuration and is inclined to the horizontal plane, with a cap covering the elevated open end, and a remotely operated plunger at the lower, closed end. After the fissionable bodies are loaded in the magazine and transported to the reactor, the plunger inserts the body at the lower end of the magazine into the reactor, then is withdrawn, thereby allowing gravity to roll the remaining bodies into position for successive loading in a similar manner.

Ohlinger, L.A.

1958-10-01T23:59:59.000Z

28

Materials Reference Books  

Science Conference Proceedings (OSTI)

Materials Science Reference Books. ... The Smithells Metals Reference Book Brandis and Brook; Butterworth-Heinemann; Published 1992; ISBN ...

2010-10-05T23:59:59.000Z

29

LOADED WAVEGUIDES  

DOE Patents (OSTI)

>Loaded waveguides are described for the propagation of electromagnetic waves with reduced phase velocities. A rectangular waveguide is dimensioned so as to cut-off the simple H/sub 01/ mode at the operating frequency. The waveguide is capacitance loaded, so as to reduce the phase velocity of the transmitted wave, by connecting an electrical conductor between directly opposite points in the major median plane on the narrower pair of waveguide walls. This conductor may take a corrugated shape or be an aperature member, the important factor being that the electrical length of the conductor is greater than one-half wavelength at the operating frequency. Prepared for the Second U.N. International ConferThe importance of nuclear standards is duscussed. A brief review of the international callaboration in this field is given. The proposal is made to let the International Organization for Standardization (ISO) coordinate the efforts from other groups. (W.D.M.)

Mullett, L.B.; Loach, B.G.; Adams, G.L.

1958-06-24T23:59:59.000Z

30

Quality Reference Samples  

Science Conference Proceedings (OSTI)

Peer-reviewed fats and oils related performance-based control samples for lab quality assurance and quality control. Quality Reference Samples Certified Reference Materials (CRM) aocs certified Certified Reference Materials chemists CRM fat fats lab labo

31

NEWTON's Computer Science References  

NLE Websites -- All DOE Office Websites (Extended Search)

Computer Science References Do you have a great computer reference link? Please click our Ideas page. Featured Reference Links: w3schools.com w3schools.com The site, w3schools.com,...

32

COSY INFINITY Reference Manual  

E-Print Network (OSTI)

7.2, user's refer- ence manual. Technical Report CERN/LEP-COSY INFINITY Reference Manual M. Berz J I July 1990COSY INFlNlTY REFERENCE MANUAL * Martin Berz Accelerator and

Berz, M.

2010-01-01T23:59:59.000Z

33

Shift Reference Manual  

E-Print Network (OSTI)

BERKELEY Shift Reference Manual Akash Deshpande Aleks Göllü1055-1425 S HIFT Reference Manual PRCS project SHIC versionThis is a reference manual for S HIFT . It presents its

Deshpande, Akash; Gollu, Aleks; Semenzato, Luigi

1997-01-01T23:59:59.000Z

34

Definition: Native Load | Open Energy Information  

Open Energy Info (EERE)

Terms Load-Serving Entity References Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline...

35

References: See Enclosure 1  

E-Print Network (OSTI)

a. Reissues DoD 4140.65-M (Reference (a)) in accordance with the authority in DoD Directive 5134.12 (Reference (b)) to establish guidance for the issuance, use, and disposal of wood packaging material (WPM) in compliance with International Standards for Phytosanitary Measures (ISPM) Number 15 (Reference (c)). When used as an adjective in this Manual, Reference (c) will be referred to as “ISPM No. 15.” b. Issues WPM procedures to:

unknown authors

2012-01-01T23:59:59.000Z

37

NPP References and Summaries  

NLE Websites -- All DOE Office Websites (Extended Search)

Full references and selected summaries (in alphabetical order of first author name by data set): Chinese Forests NPP Data Set References Gao, Q. and X.S. Zhang (1997) A simulation...

38

Standard Reference Data  

Science Conference Proceedings (OSTI)

... The National Standard Reference Data System (NSRDS-NBS) provides access to the quantitative data of physical sciences, critically evaluated ...

2013-09-19T23:59:59.000Z

39

Standard Reference Materials  

Science Conference Proceedings (OSTI)

... Inn, KGW, Liggett, WS, and Hutchinson, JMR (1984), "The National Bureau of Standards Rocky Flats Soil Standard Reference Material," Nuclear ...

40

Data center reference lists  

Science Conference Proceedings (OSTI)

Data Center Publications. Use the following form to retrieve a list of references to critical compilations, databases, reviews ...

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

A Novel Approach to Determining Motor Load  

E-Print Network (OSTI)

Properly sized electric motors are essential if industrial plant efficiency is to be optimized and energy costs minimized. Because of the difficulty in making power measurements on three phase motors, loading is rarely, if ever, checked. A simple indication of motor load can be achieved by measuring operating speed because speed and load are almost linearly related. The decrease in motor speed from no load conditions, referred to as slip, can be determined with a non-contact, optical tachometer. Field measurements of motor slip were conducted at a textile plant to quantify motor load conditions. To verify the relationship between operating speed and load, measurements of motor power consumption on a representative number of motors were also conducted. The results of the motor survey, including number of motors, size, and load, are summarized in this paper along with an estimate of the savings from replacing oversized motors.

Brown, M.

1992-04-01T23:59:59.000Z

42

Commercial Reference Building: Hospital | OpenEI  

Open Energy Info (EERE)

09 09 Varnish cache server Browse Upload data GDR 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142278309 Varnish cache server Commercial Reference Building: Hospital Dataset Summary Description Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus simulation software. Included here is data pertaining to the reference building type Hospital for each of the 16 climate zones, and each of three construction categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings.The dataset includes four key components: building summary, zone summary, location summary and a picture. Building summary includes details about: form, fabric, and HVAC. Zone summary includes details such as: area, volume, lighting, and occupants for all types of zones in the building. Location summary includes key building information as it pertains to each climate zone, including: fabric and HVAC details, utility costs, energy end use, and peak energy demand.In total, DOE developed 16 reference building types that represent approximately 70% of commercial buildings in the U.S.; for each type, building models are available for each of the three construction categories. The commercial reference buildings (formerly known as commercial building benchmark models) were developed by the U.S. Department of Energy (DOE), in conjunction with three of its national laboratories.Additional data is available directly from DOE's Energy Efficiency & Renewable Energy (EERE) Website, including EnergyPlus software input files (.idf) and results of the EnergyPlus simulations (.html).

43

Chemical Reference Data Group Homepage  

Science Conference Proceedings (OSTI)

Chemical Reference Data Group. Welcome. The Chemical Reference Data Group compiles, evaluates, correlates and measures ...

2013-07-10T23:59:59.000Z

44

High frequency reference electrode  

DOE Patents (OSTI)

A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo'' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes.

Kronberg, J.W.

1991-03-05T23:59:59.000Z

45

High frequency reference electrode  

DOE Patents (OSTI)

A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes. 4 figs.

Kronberg, J.W.

1994-05-31T23:59:59.000Z

46

High frequency reference electrode  

DOE Patents (OSTI)

A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or "halo" at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes.

Kronberg, James W. (Aiken, SC)

1994-01-01T23:59:59.000Z

47

Periodic load balancing  

Science Conference Proceedings (OSTI)

Multiprocessor load balancing aims to improve performance by moving jobs from highly loaded processors to more lightly loaded processors. Some schemes allow only migration of new jobs upon arrival, while other schemes allow migration of ... Keywords: heavy traffic diffusion approximations, load balancing, periodic load balancing, reflected Brownian motion, resource sharing, transient behavior

Gísli Hjálmtýsson; Ward Whitt

1998-06-01T23:59:59.000Z

48

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

49

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.

Rankin, R.; Kotter, D.

1992-12-31T23:59:59.000Z

50

APPENDIX B: REFERENCES  

NLE Websites -- All DOE Office Websites (Extended Search)

2010 Appendix B: References Bloomfield, K., J.N. Moore, and R.M. Neilson Jr. 2003. Geothermal Energy Reduces Greenhouse Gases. Geothermal Research Council. GRC Bulletin, April...

51

NEWTON's References About Mathematics  

NLE Websites -- All DOE Office Websites (Extended Search)

Please click our Ideas page. Featured Reference Links: Free Math Video Lectures Mathematics Online Courses View 100s of free instructional math videos. FreeVideoLectures...

52

The Conniver Reference Manual  

E-Print Network (OSTI)

This manual is an introduction and reference to the latest version of the Conniver programming language, an AI language wit general control and data-base structures.

McDermott, Drew V.

1972-05-01T23:59:59.000Z

53

NEWTON's Botany References  

NLE Websites -- All DOE Office Websites (Extended Search)

Botany References Botany References Do you have a great botany reference link? Please click our Ideas page. Featured Reference Links: Dave's Garden - Plant Database Dave's Garden - Plant Database Visit Dave's Garden with information and photos for 185,359 different plants! United States Department of Agriculture Plant Database USDA PLANTS Database The PLANTS Database provides standardized information about the vascular plants, mosses, liverworts, hornworts, and lichens of the U.S. and its territories. Search over 40,000 plant images of US plants. Botany.com Botany.com Botany.com offers an encyclopedia of flowers and plants and resources to help people learn how to identify any different kinds of plants. Plant Kingdom This is a good reference for looking at the plant kingdom.

54

NEWTON's General Science References  

NLE Websites -- All DOE Office Websites (Extended Search)

General Science References General Science References Do you have a great general science reference link? Please click our Ideas page. Featured Reference Links: First.gov Science and Technology First.gov Science and Technology This site, sponsered by the US Government provides reference links to topics on science, telecommunications, computers, research agencies, and news. NASA Science NASA Science NASA Science, is a website sponsered by NASA, that supplies resources for understanding our world and the world above. Topics include earth science, heliophysics, the planets, astrophysics and much more. There is also an educator page! Nobel Laueate Listings and Stories Nobel Laueate Listings and Stories See the official site for the Nobel Prize, and read biographies about all of the Nobel Laureates, and there life changing discoveries and accomplishments.

55

Wilderness Preservation : a Reference Handbook  

E-Print Network (OSTI)

Preservation: A Reference Handbook By Kenneth A. RossenbergPreservation: A Reference Handbook. Santa Barbara: ABC-CLIO,Preservation: A Reference Handbook is a comprehensive

Zimmer, Peter

1996-01-01T23:59:59.000Z

56

Quality assessment of GPS reprocessed terrestrial reference frame  

Science Conference Proceedings (OSTI)

The International GNSS Service (IGS) contributes to the construction of the International Terrestrial Reference Frame (ITRF) by submitting time series of station positions and Earth Rotation Parameters (ERP). For the first time, its submission to the ... Keywords: GNSS, Geocenter motion, Loading, Systematic errors, Terrestrial reference frames

Xavier Collilieux; Laurent Métivier; Zuheir Altamimi; Tonie Dam; Jim Ray

2011-07-01T23:59:59.000Z

57

NEWTON's Molecular Biology References  

NLE Websites -- All DOE Office Websites (Extended Search)

Molecular Biology References Molecular Biology References Do you have a great reference link? Please click our Ideas page. Featured Reference Links: The Vitual Museum of Bacteria The Vitual Museum of Bacteria Visit the virtual museum of bacteria to learn more about bacteria and germs! This site brings together many links on bacteria, bacteriology, and related topics available on the web. It also provides crystal-clear information about many aspects of bacteria. The American Society of Cell Biology Cell Biology Educational Resources This site, sponsered by the American Society of Cell Biology, provides additional web links to everything from, general educational sites, to biology course materials, to teaching tools and more. National Center for Biotechnology Information National Center for Biotechnology Information

58

Transforming Definitions of Reference  

E-Print Network (OSTI)

“Four components of reference service: 1. Instruct the reader in the ways of the library. 2. Assist readers in solving their inquiries. 3. Aid the reader in the selection of good works. 4. Promote the library within the community.” Green, S.S. (1876). Personal relations between librarian and readers. American Library Journal, 1, 74-81. 1943 “Reference work. 1. That phase of library work which is directly concerned with assistance to readers in securing information and in using the resources of the library in study and research. 2. The work of a reference department.” American Library Association. Committee on Library Terminology. (1943). A.L.A. glossary of library terms, with a selection of terms in related fields. Chicago: American Library Association. 1982 “Reference transaction An information contact which involves the use, recommendation, interpretation, or instruction in the use of one or more information sources, or knowledge of such

unknown authors

2008-01-01T23:59:59.000Z

59

References to Astrophysics Papers  

NLE Websites -- All DOE Office Websites (Extended Search)

References to Astrophysics Papers References to Astrophysics Papers References to Astrophysics Papers Edward Tufte claims the most common number of references to scientific papers is zero. My five papers in astrophysics published from 1992 to 1996 continue to receive citations. Major ones are listed below. Mineo, S.; Rappaport, S.; Steinhorn, B.; Levine, A.; Gilfanov, M.; Pooley, D., 2013, The Astrophysical Journal, Volume 771, Issue 2, article id. 133, 12 pp. Spatially Resolved Star Formation Image and the Ultraluminous X-Ray Source Population in NGC 2207/IC 2163 Junqueira, T. C.; Lépine, J. R. D.; Braga, C. A. S.; Barros, D. A 2013, Astronomy & Astrophysics, Volume 550, id.A91. A new model for gravitational potential perturbations in disks of spiral galaxies. An application to our Galaxy.

60

NEWTON's References About Mathematics  

NLE Websites -- All DOE Office Websites (Extended Search)

Math References Math References Do you have a great math reference link? Please click our Ideas page. Featured Reference Links: Steve Marsden's Chemistry Resources Discovery Education's Mathematics Guide Discovery Educators have provided a Mathematics Guide for Educators. Included are numerous links to sites that touch on almost every mathematic topic that you are interested in. The Ultimate Math Portal The Ultimate Math Portal Whether you are confused by multiplication, need extra practice with geometry proofs, find yourself struggling to understand logarithms, or you just want to know more about pi, you are sure to find what you need with this great list of math facts and resources. MathIsFun.com MathIsFun.com Here, math is explained in easy language, for your students to understand. Plus, there are puzzles, games, quizzes, worksheets and a forum for more exploration. This site is designed for K-12 kids, teachers and parents to enjoy.

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

NEWTON's Material Science References  

NLE Websites -- All DOE Office Websites (Extended Search)

Material Science References Material Science References Do you have a great material science reference link? Please click our Ideas page. Featured Reference Links: Materials Research Society Materials Research Society The Materials Research Society has assembled many resources in its Materials Science Enthusiasts site. This site has information for the K-12 audience, general public, and materials science professionals. Material Science nanoHUB nanHUB.org is the place for nanotechnology research, education, and collaboration. There are Simulation Programs, Online Presentations, Courses, Learning Modules, Podcasts, Animations, Teaching Materials, and more. (Intened for high school and up) Materials Science Resources on the Web Materials Science Resources on the Web This site gives a good general introduction into material science. Sponsered by Iowa State, it talks about what material science is, ceramics and composites, and other topics.

62

References - Energy Information Administration  

U.S. Energy Information Administration (EIA)

References 1.En ergy In for ma tion Ad min istra tion. Natu ral Gas Pro - duc tive Ca pac ity for the Lower 48 States 1980 through 1991 . DOE/EIA- 0542 (Wash ing ton ...

63

LLSIM Reference Manual  

E-Print Network (OSTI)

A program that simulates a Digital Equipment Corporation PDP-11 computer and many of its peripherals on the AI Laboratory Time Sharing System (ITS) is described from a user's reference point of view. This simulator has ...

Eastlake, Donald

1971-12-01T23:59:59.000Z

64

MIT Scheme Reference Manual  

E-Print Network (OSTI)

MIT Scheme is an implementation of the Scheme programming language that runs on many popular workstations. The MIT Scheme Reference Manual describes the special forms, procedures, and datatypes provided by the ...

Hanson, Chris

1991-01-01T23:59:59.000Z

65

LLSIM Reference Manual  

E-Print Network (OSTI)

A program that simulates a Digital Equipment Corporation PDP-11 computer and many of its peripherals on the AI Laboratory Time Sharing System (ITS) is described from a user's reference point of view. This simulator has ...

Eastlake, Donald E.

1972-02-01T23:59:59.000Z

66

Technical Reference OVERVIEW  

NLE Websites -- All DOE Office Websites (Extended Search)

and the ENERGY STAR Score in the United States and Canada Page 1 Parking and the ENERGY STAR Score in the United States and Canada Technical Reference OVERVIEW The ENERGY STAR...

67

Battery loading device  

SciTech Connect

A battery loading device for loading a power source battery, built in small appliances having a battery loading chamber for selectively loading a number of cylindrical unit batteries or a one body type battery having the same voltage as a number of cylindrical unit batteries, whereby the one body type battery and the battery loading chamber are shaped similarly and asymmetrically in order to prevent the one body type battery from being inserted in the wrong direction.

Phara, T.; Suzuki, M.

1984-08-28T23:59:59.000Z

68

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network (OSTI)

composition: The total load profile obtained from  load individual load types if  load profiles of individual load composition validation: Load profiles generated by the load 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

69

Quality Assurance REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Quality Assurance Quality Assurance Qualification Standard DOE-STD-1150-2002 July 2012 Reference Guide The Functional Area Qualification Standard References Guides are developed to assist operators, maintenance personnel, and the technical staff in the acquisition of technical competence and qualification within the Technical Qualification Program. Please direct your questions or comments related to this document to the Office of Leadership and Career Management, Technical Qualification Program (TQP) Manager, Albuquerque Complex. This page is intentionally blank. Table of Contents i FIGURES ....................................................................................................................................... ii TABLES ........................................................................................................................................ iii

70

Multifunctional reference electrode  

DOE Patents (OSTI)

A multifunctional, low mass reference electrode of a nickel tube, thermocouple means inside the nickel tube electrically insulated therefrom for measuring the temperature thereof, a housing surrounding the nickel tube, an electrolyte having a fixed sulfide ion activity between the housing and the outer surface of the nickel tube forming the nickel/nickel sulfide/sulfide half-cell are described. An ion diffusion barrier is associated with the housing in contact with the electrolyte. Also disclosed is a cell using the reference electrode to measure characteristics of a working electrode.

Redey, L.; Vissers, D.R.

1981-12-30T23:59:59.000Z

71

TERMS OF REFERENCE  

E-Print Network (OSTI)

Act 2002 (the Act), hereby makes a reference to the CC for an investigation into the supply or acquisition of PH in the UK. 2. The OFT has reasonable grounds for suspecting that a feature or a combination of features of the market or markets for the supply or acquisition of PH prevents, restricts or distorts competition. 3. For the purposes of this reference, PH means privately funded healthcare services. These are services provided to patients via private facilities/clinics including private patient units, through the services of consultants, medical and clinical

John Fingleton

2012-01-01T23:59:59.000Z

72

Aluminum reference electrode  

DOE Patents (OSTI)

A stable reference electrode for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na.sub.3 AlF.sub.6, wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution.

Sadoway, Donald R. (Belmont, MA)

1988-01-01T23:59:59.000Z

73

Aluminum reference electrode  

DOE Patents (OSTI)

A stable reference electrode is described for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na[sub 3]AlF[sub 6], wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution. 1 fig.

Sadoway, D.R.

1988-08-16T23:59:59.000Z

74

Definition: Direct Load Control Device | Open Energy Information  

Open Energy Info (EERE)

Load Control Device Load Control Device Jump to: navigation, search Dictionary.png Direct Load Control Device A remotely controllable switch that can turn power to a load or appliance on or off. Such a device could also be used to regulate the amount of power that a load can consume. Direct load control devices can be operated by a utility or third party energy provider to reduce a customer's energy demand at certain times.[1] Related Terms power, load References ↑ https://www.smartgrid.gov/category/technology/direct_load_control_device [[Ca LikeLike UnlikeLike You like this.Sign Up to see what your friends like. tegory: Smart Grid Definitionssmart grid,smart grid, |Template:BASEPAGENAME]]smart grid,smart grid, Retrieved from "http://en.openei.org/w/index.php?title=Definition:Direct_Load_Control_Device&oldid=502631

75

EPRI HVDC Reference Book  

Science Conference Proceedings (OSTI)

This report is actually Chapter 17 of the EPRI HVDC Reference Book and describes a variety of simulation tools for high-voltage direct current (HVDC) systems. Modeling and simulation of HVDC systems is essential in the planning, engineering, designing, and operating stages of an HVDC system.

2008-04-15T23:59:59.000Z

76

Radwaste Desk Reference  

Science Conference Proceedings (OSTI)

This volume of the Radwaste Desk Reference contains fundamental practical and regulatory information on the transportation of radioactive waste. Because its information is based entirely on industry practice, the work can serve as an extensive how-to manual for both the newcomer and the experienced radwaste professional.

2011-07-28T23:59:59.000Z

77

Load sensing system  

DOE Patents (OSTI)

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast

Sohns, Carl W. (Oak Ridge, TN); Nodine, Robert N. (Knoxville, TN); Wallace, Steven Allen (Knoxville, TN)

1999-01-01T23:59:59.000Z

78

Discharge circuits and loads  

SciTech Connect

This will be an overview in which some of the general properties of loads are examined: their interface with the energy storage and switching devices; general problems encountered with different types of loads; how load behavior and fault modes can impact on the design of a power conditioning system (PCS).

Sarjeant, W.J.

1980-10-15T23:59:59.000Z

79

NEWTON's Botany References  

NLE Websites -- All DOE Office Websites (Extended Search)

Botany References Botany References Do you have a great botany video? Please click our Ideas page. Featured Videos: AOL News AOL News - Botany Videos AOL news provides hundreds of botany videos from around the world. View informational and instructional videos as well as interviews about the latest botany topics and discoveries. NeoK12 Plant Videos NeoK12 - Every Plant Topic Imaginable Explore videos encompassing every category dealing with plants. Learn about photosynthesis, plant evolution, reproduction, and many more plant related videos. Fungus Image Fungi Videos BBC Nature provides informational videos about fugni and other organisms. Learn and explore a wide variety of topics concerning the fungus kingdom. Other Botany Videos: Botany Videos for Kids Look at various botany videos geared towards a younger audience.

80

Reference Undulator Measurement Results  

SciTech Connect

The LCLS reference undulator has been measured 22 times during the course of undulator tuning. These measurements provide estimates of various statistical errors. This note gives a summary of the reference undulator measurements and it provides estimates of the undulator tuning errors. We measured the reference undulator many times during the tuning of the LCLS undulators. These data sets give estimates of the random errors in the tuned undulators. The measured trajectories in the reference undulator are stable and straight to within {+-}2 {micro}m. Changes in the phase errors are less than {+-}2 deg between data sets. The phase advance in the cell varies by less than {+-}2 deg between data sets. The rms variation between data sets of the first integral of B{sub x} is 9.98 {micro}Tm, and the rms variation of the second integral of B{sub x} is 17.4 {micro}Tm{sup 2}. The rms variation of the first integral of B{sub y} is 6.65 {micro}Tm, and the rms variation of the second integral of B{sub y} is 12.3 {micro}Tm{sup 2}. The rms variation of the x-position of the fiducialized beam axis is 35 {micro}m in the final production run This corresponds to an rms uncertainty in the K value of {Delta}K/K = 2.7 x 10{sup -5}. The rms variation of the y-position of the fiducialized beam axis is 4 {micro}m in the final production run.

Wolf, Z

2011-08-18T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

MATLAB r ? / R Reference  

E-Print Network (OSTI)

I wrote the first version of this reference during the Spring 2007 semester, as I learned R while teaching my course “MAT400, Modeling & Simulation ” at the University of Maine. The course covers population and epidemiological modeling, including deterministic and stochastic models in discrete and continuous time, along with spatial models. Half of the class meetings are in a regular classroom, and half are in a computer lab where students work through modeling & simulation exercises. When I taught earlier versions of the course, it was based on Matlab only. In Spring 2007, some biology graduate students in the class who had learned R in statistics courses asked if they could use R in my class as well, and I said yes. My colleague Bill Halteman was a great help as I frantically learned R to stay ahead of the class. As I went, every time I learned how to do something in R for the course, I added it to this reference, so that I wouldn’t forget it later. Some items took a huge amount of time searching for a simple way to do what I wanted, but at the end of the semester, I was pleasantly surprised that almost everything I do in Matlab had an equivalent in R. I was also inspired to do this after seeing the “R for Octave Users” reference written by Robin Hankin. This reference is organized into general categories. There is also a Matlab index and an R index at the end, which should make it easy to look up a command you know in one of the languages and learn

David Hiebeler

2008-01-01T23:59:59.000Z

82

Load controller and method to enhance effective capacity of a photovotaic power supply using a dynamically determined expected peak loading  

DOE Patents (OSTI)

A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The expected peak loading of the variable load can be dynamically determined within a defined time interval with reference to variations in the variable load.

Perez, Richard (Delmar, NY)

2003-04-01T23:59:59.000Z

83

NIST Standard Reference Simulation Website  

Science Conference Proceedings (OSTI)

... simulations, that can be treated similar to "standard reference data ... techniques and compiled by NIST under the Standards Reference Data Program. ...

2013-08-27T23:59:59.000Z

84

Definition: Base Load | Open Energy Information  

Open Energy Info (EERE)

Load Load Jump to: navigation, search Dictionary.png Base Load The minimum amount of electric power delivered or required over a given period at a constant rate.[1] View on Wikipedia Wikipedia Definition Baseload (also base load, or baseload demand) is the minimum amount of power that a utility or distribution company must make available to its customers, or the amount of power required to meet minimum demands based on reasonable expectations of customer requirements. Baseload values typically vary from hour to hour in most commercial and industrial areas. Related Terms electricity generation, power, smart grid References ↑ Glossary of Terms Used in Reliability Standards An in Like Like You like this.Sign Up to see what your friends like. line Glossary Definition Retrieved from

85

Modeling and control of thermostatically controlled loads  

SciTech Connect

As the penetration of intermittent energy sources grows substantially, loads will be required to play an increasingly important role in compensating the fast time-scale fluctuations in generated power. Recent numerical modeling of thermostatically controlled loads (TCLs) has demonstrated that such load following is feasible, but analytical models that satisfactorily quantify the aggregate power consumption of a group of TCLs are desired to enable controller design. We develop such a model for the aggregate power response of a homogeneous population of TCLs to uniform variation of all TCL setpoints. A linearized model of the response is derived, and a linear quadratic regulator (LQR) has been designed. Using the TCL setpoint as the control input, the LQR enables aggregate power to track reference signals that exhibit step, ramp and sinusoidal variations. Although much of the work assumes a homogeneous population of TCLs with deterministic dynamics, we also propose a method for probing the dynamics of systems where load characteristics are not well known.

Backhaus, Scott N [Los Alamos National Laboratory; Sinitsyn, Nikolai [Los Alamos National Laboratory; Kundu, S. [UNIV OF MICHIGAN; Hiskens, I. [UNIV OF MICHIGAN

2011-01-04T23:59:59.000Z

86

Load sensing system  

DOE Patents (OSTI)

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast inventories of stored nuclear material can be continuously monitored and inventoried of minimal cost. 4 figs.

Sohns, C.W.; Nodine, R.N.; Wallace, S.A.

1999-05-04T23:59:59.000Z

87

Technical Reference OVERVIEW  

NLE Websites -- All DOE Office Websites (Extended Search)

Parking and the ENERGY STAR Score in the United States and Canada Page 1 Parking and the ENERGY STAR Score in the United States and Canada Page 1 Parking and the ENERGY STAR Score in the United States and Canada Technical Reference OVERVIEW The ENERGY STAR score provides a fair assessment of the energy performance of a property relative to its peers, taking into account the climate, weather, and business activities at the property. Parking areas are not eligible to earn the ENERGY STAR score. However, because parking is a common amenity at other commercial building types (i.e., office and hotels), the ENERGY STAR score does make adjustments to accommodate for the presence of parking.

88

Long life reference electrode  

DOE Patents (OSTI)

An external, reference electrode is provided for long term use with a high temperature, high pressure system. The electrode is arranged in a vertical, electrically insulative tube with an upper portion serving as an electrolyte reservoir and a lower portion in electrolytic communication with the system to be monitored. The lower end portion includes a flow restriction such as a porous plug to limit the electrolyte release into the system. A piston equalized to the system pressure is fitted into the upper portion of the tube to impart a small incremental pressure to the electrolyte. The piston is selected of suitable size and weight to cause only a slight flow of electrolyte through the porous plug into the high pressure system. This prevents contamination of the electrolyte but is of such small flow rate that operating intervals of a month or more can be achieved. 2 figs.

Yonco, R.M.; Nagy, Z.

1989-04-04T23:59:59.000Z

89

Nuclear Science References Database  

E-Print Network (OSTI)

The Nuclear Science References (NSR) database together with its associated Web interface, is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 210,000 articles since the beginning of nuclear science. The weekly-updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center http://www.nndc.bnl.gov/nsr and the International Atomic Energy Agency http://www-nds.iaea.org/nsr.

B. Pritychenko; E. B?ták; B. Singh; J. Totans

2013-02-27T23:59:59.000Z

90

Tank characterization reference guide  

Science Conference Proceedings (OSTI)

Characterization of the Hanford Site high-level waste storage tanks supports safety issue resolution; operations and maintenance requirements; and retrieval, pretreatment, vitrification, and disposal technology development. Technical, historical, and programmatic information about the waste tanks is often scattered among many sources, if it is documented at all. This Tank Characterization Reference Guide, therefore, serves as a common location for much of the generic tank information that is otherwise contained in many documents. The report is intended to be an introduction to the issues and history surrounding the generation, storage, and management of the liquid process wastes, and a presentation of the sampling, analysis, and modeling activities that support the current waste characterization. This report should provide a basis upon which those unfamiliar with the Hanford Site tank farms can start their research.

De Lorenzo, D.S.; DiCenso, A.T.; Hiller, D.B.; Johnson, K.W.; Rutherford, J.H.; Smith, D.J. [Los Alamos Technical Associates, Kennewick, WA (United States); Simpson, B.C. [Westinghouse Hanford Co., Richland, WA (United States)

1994-09-01T23:59:59.000Z

91

Structural load combinations  

SciTech Connect

This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane eqrthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10/sup -6/ or 1.0 x 10/sup -5/ during a lifetime of 40 years. 23 refs., 9 tabs.

Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

1985-01-01T23:59:59.000Z

92

Watershed Mercury Loading Framework  

Science Conference Proceedings (OSTI)

This report explains and illustrates a simplified stochastic framework, the Watershed Mercury Loading Framework, for organizing and framing site-specific knowledge and information on mercury loading to waterbodies. The framework permits explicit treatment of data uncertainties. This report will be useful to EPRI members, state and federal regulatory agencies, and watershed stakeholders concerned with mercury-related human and ecological health risk.

2003-05-23T23:59:59.000Z

93

Load-management decision  

Science Conference Proceedings (OSTI)

Utilities require baseload, intermediate, and peaking plants to meet fluctuating customer demand. These can be supplemented with off-peak generation and storage and load management, which can take the form of direct utility control over interruptible and deferrable customers or customer incentives that require off-peak demand. Utilities should make a careful analysis of their load profile, their generation mix, their ability to shift loads, and customer attitudes before deciding on a load-management program that fits their individual needs. They should also be aware that load management is only a limited resource with a number of uncertainties. Research programs into customer relations, system reliability, communications devices, and special control switches and meters will help to relieve some of the uncertainties. (DCK)

Lihach, N.; Gupta, P.

1982-05-01T23:59:59.000Z

94

Commercial and Residential Hourly Load Data Now Available on OpenEI! |  

Open Energy Info (EERE)

Commercial and Residential Hourly Load Data Now Available on OpenEI! Commercial and Residential Hourly Load Data Now Available on OpenEI! Home > Groups > Utility Rate Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 12:03 building load building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL I am pleased to announce that simulated hourly residential and commercial building load datasets are now available on OpenEI. These datasets are available for all TMY3 locations in the United States. They contain hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). In addition to various

95

Dehumidification and cooling loads from ventilation air  

SciTech Connect

The importance of controlling humidity in buildings is cause for concern, in part, because of indoor air quality problems associated with excess moisture in air-conditioning systems. But more universally, the need for ventilation air has forced HVAC equipment (originally optimized for high efficiency in removing sensible heat loads) to remove high moisture loads. To assist cooling equipment and meet the challenge of larger ventilation loads, several technologies have succeeded in commercial buildings. Newer technologies such as subcool/reheat and heat pipe reheat show promise. These increase latent capacity of cooling-based systems by reducing their sensible capacity. Also, desiccant wheels have traditionally provided deeper-drying capacity by using thermal energy in place of electrical power to remove the latent load. Regardless of what mix of technologies is best for a particular application, there is a need for a more effective way of thinking about the cooling loads created by ventilation air. It is clear from the literature that all-too-frequently, HVAC systems do not perform well unless the ventilation air loads have been effectively addressed at the original design stage. This article proposes an engineering shorthand, an annual load index for ventilation air. This index will aid in the complex process of improving the ability of HVAC systems to deal efficiently with the amount of fresh air the industry has deemed useful for maintaining comfort in buildings. Examination of typical behavior of weather shows that latent loads usually exceed sensible loads in ventilation air by at least 3:1 and often as much as 8:1. A designer can use the engineering shorthand indexes presented to quickly assess the importance of this fact for a given system design. To size those components after they are selected, the designer can refer to Chapter 24 of the 1997 ASHRAE Handbook--Fundamentals, which includes separate values for peak moisture and peak temperature.

Harriman, L.G. III [Mason-Grant, Portsmouth, NH (United States); Plager, D. [Quantitative Decision Support, Portsmouth, NH (United States); Kosar, D. [Gas Research Inst., Chicago, IL (United States)

1997-11-01T23:59:59.000Z

96

LAI References and Summaries  

NLE Websites -- All DOE Office Websites (Extended Search)

Cart Sign In/Register Quick Data Search Help icon Go NASA Meatball Cart Sign In/Register Quick Data Search Help icon Go NASA Meatball No JAVASCRIPT Capabilities. This site will not function without JavaScript. Please use the Web Product Tree. or anonymous FTP at ftp://daac.ornl.gov/data. Global Leaf Area Index Data from Field Measurements, 1932-2000 References and summaries for literature on leaf area index (reviews, methodology, etc.) Barclay, H. J. (1998) Conversion of total leaf area to projcted leaf area in lodgepole pine and Douglas-fir. Tree PHysiology 18, 185-193. Summary It is noted that three distinct definitions of leaf area index (LAI) in the literature have no predictable relationship with each other. Conversion factors were derived, from total LAI to projected LAI of horizontal leaves and to projected LAI for inclined leaves of lodgepole pine and coastal Douglas-fir, enabling comparison of results from different studies. An algorithm was derived to allow determination of these factors based on twig angles and the angles that the foliage subtends with the twig. The conversion factor was more sensitive to differences in vertical angles of the twigs than to twig rotation or foliar arrangement on the twig.

97

Reference: Revised Tariff Sheet  

E-Print Network (OSTI)

Company (TrAILCo), a revised tariff sheet to correct the FERC Form No. 1 line reference in TrAILCo’s formula rate. Pursuant to the authority delegated to the Director, Division of Electric Power Regulation- East, under 18 C.F.R. § 375.307, your submittal filed in the above referenced docket is accepted for filing, effective May 17, 2010, as requested. 1 Notice of the filing was published in the Federal Register, with comments, protests, or interventions due on or before June 3, 2010. No protests or adverse comments were filed. American Municipal Power, Inc. and PJM Interconnection, LLC filed timely motions to intervene. Notices of intervention and unopposed timely filed motions to intervene are granted pursuant to Rule 214 of the Commission’s Rules of Practice and Procedure (18 C.F.R. § 385.214). Any opposed or untimely filed motion to intervene is governed by the provisions of Rule 214. This acceptance for filing shall not be construed as constituting approval of any rate, charge, classification or any rule, regulation, or practice affecting such rate or 1

Stephen Angle Esq; Dear Mr. Angle; Jignasa P. Gadani

2010-01-01T23:59:59.000Z

98

Sensor Characteristics Reference Guide  

Science Conference Proceedings (OSTI)

The Buildings Technologies Office (BTO), within the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), is initiating a new program in Sensor and Controls. The vision of this program is: • Buildings operating automatically and continuously at peak energy efficiency over their lifetimes and interoperating effectively with the electric power grid. • Buildings that are self-configuring, self-commissioning, self-learning, self-diagnosing, self-healing, and self-transacting to enable continuous peak performance. • Lower overall building operating costs and higher asset valuation. The overarching goal is to capture 30% energy savings by enhanced management of energy consuming assets and systems through development of cost-effective sensors and controls. One step in achieving this vision is the publication of this Sensor Characteristics Reference Guide. The purpose of the guide is to inform building owners and operators of the current status, capabilities, and limitations of sensor technologies. It is hoped that this guide will aid in the design and procurement process and result in successful implementation of building sensor and control systems. DOE will also use this guide to identify research priorities, develop future specifications for potential market adoption, and provide market clarity through unbiased information

Cree, Johnathan V.; Dansu, A.; Fuhr, P.; Lanzisera, Steven M.; McIntyre, T.; Muehleisen, Ralph T.; Starke, M.; Banerjee, Pranab; Kuruganti, T.; Castello, C.

2013-04-01T23:59:59.000Z

99

Radioactivity Standard Reference Material Program  

Science Conference Proceedings (OSTI)

... Summary: The Standard Reference Materials Program of the National Institute of Standards and Technology (NIST) provides science, industry, and ...

2013-03-27T23:59:59.000Z

100

Chemistry Standard Reference Materials Portal  

Science Conference Proceedings (OSTI)

... Bombings. photo of Gulf of Mexico crude oil SRM NIST Releases Gulf of Mexico Crude Oil Reference Material. canine officer ...

2013-09-19T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

NIST Standard Reference Database 23  

Science Conference Proceedings (OSTI)

... 6 Sample MATLAB Code.....53 B ... the IIR and ASHRAE reference states ... in slightly different values than ...

2011-01-03T23:59:59.000Z

102

Molecular diagnostics: harmonization through reference ...  

Science Conference Proceedings (OSTI)

... GeT-RM: Genetic Testing Reference Materials Coordination Program; HSS: Department of Health and Human Services; IRMM: Institute for ...

2012-10-09T23:59:59.000Z

103

Energy and American Society : a Reference Handbook  

E-Print Network (OSTI)

American Society: A Reference Handbook By E. Willard MillerSOCIETY: A REFERENCE HANDBOOK (Contemporary World IssuesSOCIETY: A REFERENCE HANDBOOK is an important reference work

Li, Haipeng

1996-01-01T23:59:59.000Z

104

building load data | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

105

electric load data | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

106

commercial load | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

107

residential load | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

108

NIST Standard Reference Database 49  

Science Conference Proceedings (OSTI)

... of the waste heat as an extra condenser load directly increases the heating capacity provided by the ... Heat transfer in turbulent pipe flow of ...

2012-05-07T23:59:59.000Z

109

HLW Glass Waste Loadings  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HLW HLW Glass Waste Loadings Ian L. Pegg Vitreous State Laboratory The Catholic University of America Washington, DC Overview Overview  Vitrification - general background  Joule heated ceramic melter (JHCM) technology  Factors affecting waste loadings  Waste loading requirements and projections  WTP DWPF  DWPF  Yucca Mountain License Application requirements on waste loading  Summary Vitrification  Immobilization of waste by conversion into a glass  Internationally accepted treatment for HLW  Why glass?  Amorphous material - able to incorporate a wide spectrum of elements over wide ranges of composition; resistant to radiation damage  Long-term durability - natural analogs Relatively simple process - amenable to nuclearization at large  Relatively simple process - amenable to nuclearization at large scale  There

110

OpenEI - load  

Open Energy Info (EERE)

are given by a location defined by the Typical Meteorological Year (TMY) for which the weather data was collected. Commercial load data is sorted by the (TMY) site as a...

111

Capillary reference half-cell  

DOE Patents (OSTI)

The present invention is a reference half-cell electrode wherein intermingling of test fluid with reference fluid does not affect the performance of the reference half-cell over a long time. This intermingling reference half-cell may be used as a single or double junction submersible or surface reference electrode. The intermingling reference half-cell relies on a capillary tube having a first end open to reference fluid and a second end open to test fluid wherein the small diameter of the capillary tube limits free motion of fluid within the capillary to diffusion. The electrode is placed near the first end of the capillary in contact with the reference fluid. The method of operation of the present invention begins with filling the capillary tube with a reference solution. After closing the first end of the capillary, the capillary tube may be fully submerged or partially submerged with the second open end inserted into test fluid. Since the electrode is placed near the first end of the capillary, and since the test fluid may intermingle with the reference fluid through the second open end only by diffusion, this intermingling capillary reference half-cell provides a stable voltage potential for long time periods. 11 figs.

Hall, S.H.

1996-02-13T23:59:59.000Z

112

Analysis of industrial load management  

SciTech Connect

Industrial Load Management, ILM, has increased the possibilities of changing load profiles and raising load factors. This paper reports on load profile measurements and feasible load management applications that could be implemented in industry e.g. bivalent systems for heating of premises and processes, load priority systems, energy storage and rescheduling processes or parts of processes due to differential electricity rates. Industrial load variations on hourly, daily and seasonal basis are treated as well as the impact by load management on load curves e g peak clipping, valley filling and increased off-peak electricity usage.

Bjork, C.O.; Karlsson, B.G.

1986-04-01T23:59:59.000Z

113

Composite Load Model Evaluation  

Science Conference Proceedings (OSTI)

The WECC load modeling task force has dedicated its effort in the past few years to develop a composite load model that can represent behaviors of different end-user components. The modeling structure of the composite load model is recommended by the WECC load modeling task force. GE Energy has implemented this composite load model with a new function CMPLDW in its power system simulation software package, PSLF. For the last several years, Bonneville Power Administration (BPA) has taken the lead and collaborated with GE Energy to develop the new composite load model. Pacific Northwest National Laboratory (PNNL) and BPA joint force and conducted the evaluation of the CMPLDW and test its parameter settings to make sure that: • the model initializes properly, • all the parameter settings are functioning, and • the simulation results are as expected. The PNNL effort focused on testing the CMPLDW in a 4-bus system. An exhaustive testing on each parameter setting has been performed to guarantee each setting works. This report is a summary of the PNNL testing results and conclusions.

Lu, Ning; Qiao, Hong (Amy)

2007-09-30T23:59:59.000Z

114

Distribution substation load impacts of residential air conditioner load control  

SciTech Connect

An ongoing experiment to monitor the substation level load impacts of end-use load control is described. An overview of the data acquisition system, experimental procedures and analysis techniques are provided. Results of the 1983 and 1984 experiments demonstrate the value of aggregate load impact monitoring as a means of verifying load research results, calculating the diversity of end-use loads, and predicting the impacts of load management on the transmission and distribution systems.

Heffner, G.C.; Kaufman, D.A.

1985-07-01T23:59:59.000Z

115

Load Monitoring CEC/LMTF Load Research Program  

SciTech Connect

This white paper addresses the needs, options, current practices of load monitoring. Recommendations on load monitoring applications and future directions are also presented.

Huang, Zhenyu; Lesieutre, B.; Yang, Steve; Ellis, A.; Meklin, A.; Wong, B.; Gaikwad, A.; Brooks, D.; Hammerstrom, Donald J.; Phillips, John; Kosterev, Dmitry; Hoffman, M.; Ciniglio, O.; Hartwell, R.; Pourbeik, P.; Maitra, A.; Lu, Ning

2007-11-30T23:59:59.000Z

116

Technical Reference and Technical Database for Hydrogen Compatibility of  

Open Energy Info (EERE)

8 8 Varnish cache server Browse Upload data GDR 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142279738 Varnish cache server Technical Reference and Technical Database for Hydrogen Compatibility of Materials Dataset Summary Description Technical Reference for Hydrogen Compatibility of MaterialsGuidance on materials selection for hydrogen service is needed to support the deployment of hydrogen as a fuel as well as the development of codes and standards for stationary hydrogen use, hydrogen vehicles, refueling stations, and hydrogen transportation. Materials property measurement is needed on deformation, fracture and fatigue of metals in environments relevant to this hydrogen economy infrastructure. The identification of hydrogen-affected material properties such as strength, fracture resistance and fatigue resistance are high priorities to ensure the safe design of load-bearing structures.To support the needs of the hydrogen community, Sandia National Laboratories is conducting an extensive review of reports and journal publications to gather existing materials data for inclusion in the Technical Reference for Hydrogen Compatibility of Materials. Additionally, Sandia is working internationally with collaborators to acquire newly generated data for inclusion in the Technical Reference. SAND2012-7321 is an archival report issued by Sandia National Laboratories representing the reference information compiled as of September 2012. Updates and additions of individual sections of this report are available at http://www.sandia.gov/matlsTechRef.Technical Database for Hydrogen Compatibility of MaterialsThe Technical Database for Hydrogen Compatibility of Materials is intended to be a complement to the Technical Reference for Hydrogen Compatibility of Materials. Although still in the development stage, the Technical Database will provide a repository of technical data measured in hydrogen and is meant to be an engineering tool to aid the selection of materials for use in hydrogen.

117

Tips: References | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

References References Tips: References April 11, 2012 - 9:03am Addthis Tips: References The following resources were used to develop the Energy Savers Guide: Tips on Saving Money and Energy at Home: Alternative Fuels and Advanced Vehicles Data Center American Council for an Energy-Efficient Economy Cool Roof Rating Council Database of State Incentives for Renewables & Efficiency (DSIRE) DOE Building America DOE Building Technologies Program DOE Building Technologies Program, 2010 Buildings Energy Databook DOE Energy Information Administration Residential Energy Consumption Survey DOE/EPA Fuel Economy Guide DOE Federal Energy Management Program DOE Office of Electricity Delivery and Energy Reliability ENERGY STAR® Green Roofs for Healthy Cities National Renewable Energy Laboratory

118

Chemistry Standard Reference Data Portal  

Science Conference Proceedings (OSTI)

... photo of Gulf of Mexico crude oil SRM NIST Releases Gulf of Mexico Crude Oil Reference Material. 11MML036_nanotubes_srm_CS ...

2013-09-19T23:59:59.000Z

119

References | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog References Home > About Us > Our Programs > Nuclear Security > Nuclear Materials Management &...

120

FAQS Reference Guide – Facility Representative  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the October 2010 edition of DOE-STD-1151-2010, Facility Representative Functional Area Qualification Standard.

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

FAQS Reference Guide – Criticality Safety  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the April 2009 edition of DOE-STD-1173-2009, Criticality Safety Functional Area Qualification Standard.

122

OpenEI - Technical Reference  

Open Energy Info (EERE)

http:en.openei.orgdatasetstaxonomyterm8710 en Technical Reference and Technical Database for Hydrogen Compatibility of Materials http:en.openei.orgdatasetsnode927...

123

FAQS Reference Guide- Chemical Processing  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the February 2010 edition of DOE-STD-1176-2010, Chemical Processing Functional Area Qualification Standard.

124

FAQS Reference Guide – Waste Management  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the January 2003 edition of DOE-STD-1159-2003, Waste Management Functional Area Qualification Standard.

125

FAQS Reference Guide – Environmental Restoration  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the November 2002 edition of DOE-STD-1157-2002, Environmental Restoration Functional Area Qualification Standard.

126

FAQS Reference Guide – Environmental Compliance  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the June 2011 edition of DOE-STD-1156-2011, Environmental Compliance Functional Area Qualification Standard.

127

Mass-Loaded Flows  

E-Print Network (OSTI)

A key process within astronomy is the exchange of mass, momentum, and energy between diffuse plasmas in many types of astronomical sources (including planetary nebulae, wind-blown bubbles, supernova remnants, starburst superwinds, and the intracluster medium) and dense, embedded clouds or clumps. This transfer affects the large scale flows of the diffuse plasmas as well as the evolution of the clumps. I review our current understanding of mass-injection processes, and examine intermediate-scale structure and the global effect of mass-loading on a flow. I then discuss mass-loading in a variety of diffuse sources.

J. M. Pittard

2006-07-13T23:59:59.000Z

128

OpenEI Community - load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

129

OpenEI Community - electric load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

130

OpenEI Community - building load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

131

OpenEI Community - residential load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

132

OpenEI Community - commercial load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

133

OpenEI Community - building load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

134

reference case | OpenEI  

Open Energy Info (EERE)

reference case reference case Dataset Summary Description This dataset comes from the Energy Information Administration (EIA), and is part of the 2011 Annual Energy Outlook Report (AEO2011). This dataset is table 1, and contains only the reference case. The dataset uses quadrillion BTUs, and quantifies the energy prices using U.S. dollars. The data is broken down into total production, imports, exports, consumption, and prices for energy types. Source EIA Date Released April 26th, 2011 (3 years ago) Date Updated Unknown Keywords 2011 AEO consumption EIA export import production reference case total energy Data application/vnd.ms-excel icon AEO2011: Total Energy Supply, Disposition, and Price Summary - Reference Case (xls, 112.8 KiB) Quality Metrics Level of Review Peer Reviewed

135

Cooling load estimation methods  

DOE Green Energy (OSTI)

Ongoing research on quantifying the cooling loads in residential buildings, particularly buildings with passive solar heating systems, is described. Correlations are described that permit auxiliary cooling estimates from monthly average insolation and weather data. The objective of the research is to develop a simple analysis method, useful early in design, to estimate the annual cooling energy required of a given building.

McFarland, R.D.

1984-01-01T23:59:59.000Z

136

LOADING AND UNLOADING DEVICE  

DOE Patents (OSTI)

A device for loading and unloading fuel rods into and from a reactor tank through an access hole includes parallel links carrying a gripper. These links enable the gripper to go through the access hole and then to be moved laterally from the axis of the access hole to the various locations of the fuel rods in the reactor tank.

Treshow, M.

1960-08-16T23:59:59.000Z

137

Multidimensional spectral load balancing  

DOE Patents (OSTI)

A method of and apparatus for graph partitioning involving the use of a plurality of eigenvectors of the Laplacian matrix of the graph of the problem for which load balancing is desired. The invention is particularly useful for optimizing parallel computer processing of a problem and for minimizing total pathway lengths of integrated circuits in the design stage.

Hendrickson, Bruce A. (Albuquerque, NM); Leland, Robert W. (Albuquerque, NM)

1996-12-24T23:59:59.000Z

138

Buildings Stock Load Control  

E-Print Network (OSTI)

Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on electricity demand control by applying some strategies in existing building to reduce it during the extreme climate period. The first part of this paper presents the objectives of the study: ? to restrict the startup polluting manufacturing units (power station), ? to limit the environmental impacts (greenhouse emission), ? to reduce the transport and distribution electricity infrastructures The second part presents the approach used to rise the objectives : ? To aggregat the individual loads and to analyze the impact of different strategies from load shedding to reduce peak power demand by: ? Developing models of tertiary buildings stocks (Schools, offices, Shops, hotels); ? Making simulations for different load shedding strategies to calculate potential peak power saving. The third part is dedicated to the description of the developed models: An assembly of the various blocks of the library of simbad and simulink permit to model building. Finally the last part prensents the study results: Graphs and tables to see the load shedding strategies impacts.

Joutey, H. A.; Vaezi-Nejad, H.; Clemoncon, B.; Rosenstein, F.

2006-01-01T23:59:59.000Z

139

Combined transmission distribution load flow model employing system reduction and voltage variable load representation  

SciTech Connect

In the few decades since its introduction the digital computer has found widespread application within the electric power industry. One of the more fruitful areas for its utilization has been in the determination of the steady-state voltage conditions throughout the system. A power system naturally breaks down into two very distinct parts: transmission and distribution, and traditionally, the voltage problem has been separated the same way. In the transmission system it is referred to as a load flow problem, and in the distribution part it is called a voltage profile. In addition, the loads are often treated differently. Transmission loads are usually considered to be constant power, and the equations that result are therefore nonlinear. In the distribution portion the loads, though specified in terms of power, are sometimes handled as constant impedances, with linear equations. This work produced a new model wherein a mesh transmission system is combined with a radial distribution system and they are solved simultaneously. A system reduction technique is used to eliminate part of the transmission system from consideration, and thereby keep the problem at a manageable size. The solution algorithm incorporates a voltage variable load model which approximates the behavior of real loads more nearly than the common representations.

Enouen, P.W.

1985-01-01T23:59:59.000Z

140

NETL: Coal & Power Systems Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Shelf Coal & Power Systems Reference Shelf Below are links to recent Strategic Center for Coal (SCC) related documents and reference materials. Each technology area...

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

FAQS Reference Guide - Transportation and Traffic Management...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

FAQS Reference Guide - Transportation and Traffic Management FAQS Reference Guide - Transportation and Traffic Management This reference guide addresses the competency statements...

142

References  

Science Conference Proceedings (OSTI)

... LIBES96. Don Libes, Writing CGI Scripts in Tcl, Proceedings of Tcl/Tk Workshop 96, Monterey, CA, July 10-13, 1996. LUB95. ...

143

References  

Science Conference Proceedings (OSTI)

... LIBES. Don Libes, Writing CGI Scripts in Tcl, Proceedings of Tcl/Tk Workshop 96, Monterey, CA, July 10-13, 1996. URL: http://www.nist.gov/msid. ...

144

References  

Science Conference Proceedings (OSTI)

..., ASM International, 2009, p 625â??658ASM Handbook, Vol 22A, Fundamentals of Modeling for Metals ProcessingHeat-Transfer Equations,...

145

References  

E-Print Network (OSTI)

Los algoritmos evolutivos (AE) son técnicas de optimización basadas en los principios de evolución natural [7]. Aunque los AEs han sido utilizados en solucionar muchos problemas de optimización de manera exitosa, el rendimiento de ellos (medido en tiempo consumido y calidad de la solución producida) depende de la selección adecuada de los parámetros del AE: Operadores genéticos, probabilidades de aplicación de los mismos, tamaño de la población, esquema de selección, etc. Es mas, el proceso de jar tales parámetros es considerado un proceso que consume mucho tiempo [10]. Tomando en cuenta la importancia de este proceso, muchos trabajos de investigación han tratado de manejarlo de diversas maneras [4]. Algunos trabajos han tratado de determinar el valor apropiado de dichos parámetros mediante experimentación extensiva de los mismos en la solución de un conjunto de funciones previamente prede nido [3, 11], o mediante un análisis teórico [5, 1, 9]. Otro conjunto de trabajos, llamados Adaptación de Parámetros (AP), han tratado de eliminar el proceso de selección de parámetros mediante la adaptación de los mismos al tiempo que el algoritmo evolutivo esta siendo ejecutado [2, 8, 13, 9, 12, 6]. En este proyecto se plantea una solución al problema de jar los parámetros mediante técnicas de auto adaptación de parámetros (Meta-evolución). Con tal n, se pretende extender el Algoritmo Evolutivo de Auto Adaptación Híbrida (HAEA por sus siglas en ingles) propuesto por Gomez en [6], de tal manera que no solamente adapte las probabilidades de los operadores genéticos sino los siguientes parámetros: Tamaño de población, mecanismos de selección y operadores genéticos.

Definición Del Problema; A. E. Eiben; R. Hinterding

2007-01-01T23:59:59.000Z

146

References  

E-Print Network (OSTI)

Application An approved SLAC Energized Electrical Work Request and Approval Permit (EEW) is required for all work at SLAC where the work includes assembly, disassembly, or re-arrangement of components while they are energized. Work below 50 volts, as well as testing, troubleshooting, and voltage measuring, are exempt from the required permit per National Fire Protection Association (NFPA) 70E 2004 Edition, Article 130.1(A)(3), provided that adequate work practices and personal protective equipment are used.

unknown authors

2005-01-01T23:59:59.000Z

147

References  

E-Print Network (OSTI)

Nowadays, lots of solar panels are installed. A major disadvantage of normal Si-based solar cells is that if one solar cell is shaded, the total energy produced by the string of solar cells is lost. Reducing the efficiency of the total system. In resent years, a new technology has been introduced, using thin film solar cells integrated into roofing. Although partial shading doesn't affect this technique as much as Si-based solar cells, the shaded solar cells do not contribute to the energy production. Some years ago a special kind of robot has been developed that automatically mows the lawn. The goal of this thesis is to build an automatic solar panel cleaning robot using a “robomow ” or other robotic vehicle. This robot has to be adapted for use on solar panels, and of course, has its own solar

unknown authors

2007-01-01T23:59:59.000Z

148

References  

E-Print Network (OSTI)

Contribution of residential wood combustion to hourly winter aerosol in Northern Sweden determined by positive matrix factorization

P. Krecl; E. Hedberg Larsson; J. Ström; C. Johansson; Wood Combustion

2008-01-01T23:59:59.000Z

149

References  

Science Conference Proceedings (OSTI)

... Edwards (eds.). 1995. SEER Cancer Statistics Review, 1973-1992: Tables and Graphs. NIH Publication No. 96-2789. Bethesda ...

1998-08-17T23:59:59.000Z

150

References  

E-Print Network (OSTI)

Why are estimates of global isoprene emissions so similar (and why is this not so for monoterpenes)?

A. Arneth; R. K. Monson; G. Schurgers; Ü. Niinemets; P. I. Palmer

2008-01-01T23:59:59.000Z

151

References  

Science Conference Proceedings (OSTI)

... Histogram Imaging", Analytical Chemistry 63(4 ... A. (1982) FUNDAMENTALS OF INTERACTIVE ... THE IMAGE PROCESSING HANDBOOK, CRC Press ...

152

References  

Science Conference Proceedings (OSTI)

... 1951) 3277-3278. [24] 'CRC Handbook of Chemistry and Physics' (CRC Press, Boca Raton, FL, 1987). [25] Thomas, JJ ...

2006-06-15T23:59:59.000Z

153

References  

NLE Websites -- All DOE Office Websites (Extended Search)

problem. In: The Second Annual International Conference on Computational Molecular Biology, (Istrail, S, Pevzner, P, Waterman, M, eds) pp. 285-292. ACM New York. Y. Xu, D. Xu,...

154

References  

NLE Websites -- All DOE Office Websites (Extended Search)

Gene-Specific Fragments for Microarrays. In "Currents in Computational Molecular Biology", edited by S. Miyano, R. Shamir and T. Takagi. Universal Academy Press, Inc. Tokyo,...

155

References  

E-Print Network (OSTI)

In analyzing the ACS photometry of the primary WD stars, Bohlin & Gilliland (2004) found a 2.5 % contribution to the predicted integrated HRC count rates due to the F660N filter transmission rise at the shortest wavelength of the tabulation. Following discussions with G. Hartig, the tabulated value of 0.00604 at 2500 Å was deemed a spurious artifact of the measurement procedure (Leviton et al. 1998a, Leviton et al. 1998b). The ACS filters generally use colored glass substrates to block short wavelengths and are not subject to the kind of UV leak that is indicated by the original data supplied by the IDT. The signal transmitted by the filter at 2500 Å in the lab measurement process was probably dominated by stray light from longer wavelengths. Even though for normal stellar continua, similar errors for other filters are less than 0.5 % of the predicted count rate, all UV transmittance curves with a similar suspicious rise in the UV are corrected to values typical of the nearest measured values. Table 1 lists all of the changes that are implemented in Synphot as a result of this investigation. These changes are also reflected in the ETC

F. R. Boffi; R. C. Bohlin

2004-01-01T23:59:59.000Z

156

References  

Science Conference Proceedings (OSTI)

... EN, Nagy, G., and Franklin, WR, 'Cracking, Damage, and Fracture in Four ... 05, 'Test Method for the Chemical Shrinkage of Hydraulic Cement Paste ...

2006-08-08T23:59:59.000Z

157

References  

U.S. Energy Information Administration (EIA)

Energy Statistics, ... 8 Elisson, H, and Elvers, E (2001), “Cut-off sampling and estimation,” Statistics Canada International Symposium Series – Proce ...

158

References  

E-Print Network (OSTI)

continuous speech recognition. IEEE Transactions on Pattern Analysis and Machine Intelligence, PAMI-5(2), March 1983. [6] Doug Beeferman, Adam Berger, and John Lafferty. A model of lexical

Steven Abney Functional Elements; Licensing Presented To Glow; J. Bach; T. C. Bell; I. H. Witten; J. L. Bentley; D. D. Sleator; R. E. Tarjan

1989-01-01T23:59:59.000Z

159

Load Capacity of Bodies  

E-Print Network (OSTI)

For the stress analysis in a plastic body $\\Omega$, we prove that there exists a maximal positive number $C$, the \\emph{load capacity ratio,} such that the body will not collapse under any external traction field $t$ bounded by $Y_{0}C$, where $Y_0$ is the elastic limit. The load capacity ratio depends only on the geometry of the body and is given by $$ \\frac{1}{C}=\\sup_{w\\in LD(\\Omega)_D} \\frac{\\int_{\\partial\\Omega}|w|dA} {\\int_{\\Omega}|\\epsilon(w)|dV}=\\left\\|\\gamma_D\\right\\|. $$ Here, $LD(\\Omega)_D$ is the space of isochoric vector fields $w$ for which the corresponding stretchings $\\epsilon(w)$ are assumed to be integrable and $\\gamma_D$ is the trace mapping assigning the boundary value $\\gamma_D(w)$ to any $w\\in LD(\\Omega)_D$.

Reuven Segev

2005-11-01T23:59:59.000Z

160

Tips: References | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: References Tips: References Tips: References April 11, 2012 - 9:03am Addthis Tips: References The following resources were used to develop the Energy Savers Guide: Tips on Saving Money and Energy at Home: Alternative Fuels and Advanced Vehicles Data Center American Council for an Energy-Efficient Economy Cool Roof Rating Council Database of State Incentives for Renewables & Efficiency (DSIRE) DOE Building America DOE Building Technologies Program DOE Building Technologies Program, 2010 Buildings Energy Databook DOE Energy Information Administration Residential Energy Consumption Survey DOE/EPA Fuel Economy Guide DOE Federal Energy Management Program DOE Office of Electricity Delivery and Energy Reliability ENERGY STAR® Green Roofs for Healthy Cities National Renewable Energy Laboratory

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Technical Reference | OpenEI  

Open Energy Info (EERE)

Reference Reference Dataset Summary Description Technical Reference for Hydrogen Compatibility of Materials Source Sandia National Laboratories Date Released June 03rd, 2010 (4 years ago) Date Updated September 27th, 2012 (2 years ago) Keywords Compatibility of Materials hydrogen NREL Sandia Technical Database Technical Reference Data application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon 1100_cia85_ten_fra_fat.xlsx (xlsx, 60.9 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon 1100_san10_fra_fat.xlsx (xlsx, 58.5 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon 1100_san10b_fra_fat.xlsx (xlsx, 59.4 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon 1100_san11_fra_fat.xlsx (xlsx, 48.4 KiB)

162

NETL: Carbon Storage - Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Carbon Storage > Reference Shelf Carbon Storage > Reference Shelf Carbon Storage Reference Shelf Below are links to Carbon Storage Program documents and reference materials. Each of the 10 categories has a variety of documents posted for easy access to current information - just click on the category link to view all related materials. RSS Icon Subscribe to the Carbon Storage RSS Feed. Carbon Storage Collage 2012 Carbon Utilization and Storage Atlas IV Carbon Sequestration Project Portfolio DOE/NETL Carbon Dioxide Capture and Storage RD&D Roadmap Public Outreach and Education for Carbon Storage Projects Carbon Storage Technology Program Plan Carbon Storage Newsletter Archive Impact of the Marcellus Shale Gas Play on Current and Future CCS Activities Site Screening, Selection, and Initial Characterization for Storage of CO2 in Deep Geologic Formations Carbon Storage Systems and Well Management Activities Monitoring, Verification, and Accounting of CO2 Stored in Deep Geologic Formations

163

Learning to resolve bridging references  

Science Conference Proceedings (OSTI)

We use machine learning techniques to find the best combination of local focus and lexical distance features for identifying the anchor of mereological bridging references. We find that using first mention, utterance distance, and lexical distance computed ...

Massimo Poesio; Rahul Mehta; Axel Maroudas; Janet Hitzeman

2004-07-01T23:59:59.000Z

164

FAQS Reference Guide –Radiation Protection  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide has been developed to address the competency statements in the December 2003 edition of DOE-STD-1174-2003, Radiation Protection Functional Area Qualification Standard.

165

Load responsive hydrodynamic bearing  

Science Conference Proceedings (OSTI)

A load responsive hydrodynamic bearing is provided in the form of a thrust bearing or journal bearing for supporting, guiding and lubricating a relatively rotatable member to minimize wear thereof responsive to relative rotation under severe load. In the space between spaced relatively rotatable members and in the presence of a liquid or grease lubricant, one or more continuous ring shaped integral generally circular bearing bodies each define at least one dynamic surface and a plurality of support regions. Each of the support regions defines a static surface which is oriented in generally opposed relation with the dynamic surface for contact with one of the relatively rotatable members. A plurality of flexing regions are defined by the generally circular body of the bearing and are integral with and located between adjacent support regions. Each of the flexing regions has a first beam-like element being connected by an integral flexible hinge with one of the support regions and a second beam-like element having an integral flexible hinge connection with an adjacent support region. A least one local weakening geometry of the flexing region is located intermediate the first and second beam-like elements. In response to application of load from one of the relatively rotatable elements to the bearing, the beam-like elements and the local weakening geometry become flexed, causing the dynamic surface to deform and establish a hydrodynamic geometry for wedging lubricant into the dynamic interface.

Kalsi, Manmohan S. (Houston, TX); Somogyi, Dezso (Sugar Land, TX); Dietle, Lannie L. (Stafford, TX)

2002-01-01T23:59:59.000Z

166

Definition: Interruptible Load Or Interruptible Demand | Open Energy  

Open Energy Info (EERE)

Interruptible Load Or Interruptible Demand Interruptible Load Or Interruptible Demand Jump to: navigation, search Dictionary.png Interruptible Load Or Interruptible Demand Demand that the end-use customer makes available to its Load-Serving Entity via contract or agreement for curtailment.[1] View on Wikipedia Wikipedia Definition View on Reegle Reegle Definition No reegle definition available. Also Known As non-firm service Related Terms transmission lines, electricity generation, transmission line, firm transmission service, smart grid References ↑ Glossary of Terms Used in Reliability Standards An inli LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ne Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Interruptible_Load_Or_Interruptible_Demand&oldid=502615"

167

A Reference Design for Residential Energy Gateways: Development and  

NLE Websites -- All DOE Office Websites (Extended Search)

A Reference Design for Residential Energy Gateways: Development and A Reference Design for Residential Energy Gateways: Development and Implications Speaker(s): Daniel Arnold Date: October 28, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Janie Page Recent advances in communications, policy, and the installation of smart meters in residences across America has opened the realm of the residence to the possibility of advanced electrical load monitoring and control. With no concrete standards or roadmaps governing communications and capabilities, a fractured market of Gateways, IHDs (In Home Displays), load control switches, and smart appliances has emerged in an attempt to take advantage of this burgeoning opportunity. What results from this mixture is a lack of interoperability amongst products, which limits consumer

168

Photovoltaic power converter system with a controller configured to actively compensate load harmonics  

DOE Patents (OSTI)

Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

de Rooij, Michael Andrew (Clifton Park, NY); Steigerwald, Robert Louis (Burnt Hills, NY); Delgado, Eladio Clemente (Burnt Hills, NY)

2008-12-16T23:59:59.000Z

169

Commercial Reference Building: Small Hotel | OpenEI  

Open Energy Info (EERE)

60 60 Varnish cache server Browse Upload data GDR 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142278160 Varnish cache server Commercial Reference Building: Small Hotel Dataset Summary Description Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus simulation software. Included here is data pertaining to the reference building type Small Hotel for each of the 16 climate zones, and each of three construction categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings.The dataset includes four key components: building summary, zone summary, location summary and a picture. Building summary includes details about: form, fabric, and HVAC. Zone summary includes details such as: area, volume, lighting, and occupants for all types of zones in the building. Location summary includes key building information as it pertains to each climate zone, including: fabric and HVAC details, utility costs, energy end use, and peak energy demand.In total, DOE developed 16 reference building types that represent approximately 70% of commercial buildings in the U.S.; for each type, building models are available for each of the three construction categories. The commercial reference buildings (formerly known as commercial building benchmark models) were developed by the U.S. Department of Energy (DOE), in conjunction with three of its national laboratories.Additional data is available directly from DOE's Energy Efficiency & Renewable Energy (EERE) Website, including EnergyPlus software input files (.idf) and results of the EnergyPlus simulations (.html).

170

Variable loading roller  

DOE Patents (OSTI)

An automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves in the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first. 14 figs.

Williams, D.M.

1988-01-21T23:59:59.000Z

171

Ris Energy Report 6 References Reference list for Chapter 3  

E-Print Network (OSTI)

. (2007). Lessons learned from recent promotion strategies for electricity from renewables in EU countries. Report on progress in renewable electricity. Brussels. (Com(2006) 849 final). 6. Danish Energy authority. References for Chapter 5 1. Brahic, C. (2007). Europe postpones decision on car emissions. New

172

Document Number Q0029500 References  

Office of Legacy Management (LM)

References References 7.0 References 10 CFR 1021. U.S. Department of Energy, "National Environmental Policy Act Implementing Procedures," Code of Federal Regzilations, January 1,2003. 10 CFR 1022. U.S. Department of Energy, "Compliance with Floodplain/Wetlands Environmental Review Requirements," Code ofFederal Regulations, January 1,2003. 33 CFR 323. Corps of Engineers, Department of the Army, "Permits for Discharges of Dredged or Fill Material Into Waters of the United States," Code ofFederal Reglllations, July 1,2002. 40 CFR 192. U.S. Environmental Protection Agency, "Health and Environmental Protection Standards for Uranium and Thorium Mill Tailings," Code of FederalReglrlations, July 1,2002. 40 CFR 230. U.S. Environmental Protection Agency, "Section 404(b)(l) Guidelines for

173

Microsoft Word - references.doc  

Office of Legacy Management (LM)

References May 2005 References May 2005 2004 Site Environmental Report R-1 References Facemire, D. F., S. I. Guttman, D. R. Osborne, and R. H. Sperger, 1990, "Biological and Ecological Site Characterization of the Feed Materials Production Center," FMPC-SUB 018, prepared for Westinghouse Materials Co. of Ohio, Cincinnati, OH. GeoSyntec, 1996, "Impacted Material Placement Plan, On-site Disposal Facility," 20100-PL-007, Revision 3, PCN 2, Prepared for the Fernald Environmental Management Project, DOE, Fernald Area Office, Cincinnati, OH, March. International Commission on Radiological Protection (ICRP), 1994a, "Human Respiratory Tract Model for Radiation Protection," ICRP Publication 66. International Commission on Radiological Protection (ICRP), 1994b, "Protection Against Radon-222

174

Chassis Dynamometer Testing Reference Document  

NLE Websites -- All DOE Office Websites (Extended Search)

Chassis Dynamometer Testing Chassis Dynamometer Testing Reference Document Downloadable Dynamometer Database www.transportation.anl.gov/D3/ Argonne, IL July, 2013 Henning Lohse-Busch, Ph.D. Kevin Stutenberg, Mike Duoba, Eric Rask, Forrest Jehlik and Glenn Keller Advanced Powertrain Research Facility Overview  This is a reference document explaining the facility and processes used to generate the data available from Argonne National Laboratory's (ANL) Downloadable Dynamometer Database (D 3 ).  Content - Advanced Powertrain Research Facility (APRF) - Chassis Dynamometer Testing Basics - Overview of Classic Drive Cycles - Test Condition and Test Sequences - Data Acquisition System and General Instrumentation Overview

175

Underground Transmission Systems Reference Book  

Science Conference Proceedings (OSTI)

The Underground Transmission Systems Reference Book covers all stages of cable system design and operation, from initial planning studies to failure analysis. It contains contributions from many of the industry's experts and represents practices from all parts of the United States.

1993-03-01T23:59:59.000Z

176

The HOL Light System REFERENCE  

E-Print Network (OSTI)

This volume is the reference manual for the HOL Light system. In contrast to the Tutorial, it is mainly intended for reference purposes, though some readers will find it productive to browse through it as part of the learning process. The main entries for the reference manual are generated from the same database that is used by the online HOL Light help system. The entries that follow provide documentation on essentially all the pre-defined ML variable bindings in the HOL Light system. These include: general-purpose functions, such as ML functions for list processing, arithmetic, input/output, and interface configuration; functions for processing the types and terms of the HOL logic and for using the subgoal package; primitive and derived forward inference rules; tactics and tacticals; and pre-proved built-in theorems. The manual entries for these ML identifiers are divided into two chapters. The first chapter is an alphabetical sequence of manual entries for all ML identifiers in the system except those identifiers that are bound to theorems (or pairs of theorems, etc.) The theorems are listed in the second chapter, roughly grouped into sections based on subject matter. Our documentation does not cover basic functions in the OCaml toplevel, such as addition, string concatenation etc. In fact, relatively few native OCaml functions are used, and those are all documented in the Objective CAML Reference Manual:

Tom Melham; Larry Paulson The Typeset

2013-01-01T23:59:59.000Z

177

MTS Table Top Load frame  

NLE Websites -- All DOE Office Websites (Extended Search)

MTS Table Top Load frame MTS Table Top Load frame The Non-destructive Evaluation group operates an MTS Table Top Load frame for ultimate strength and life cycle testing of various ceramic, ceramic-matrix (FGI), carbon, carbon fiber, cermet (CMC) and metal alloy engineering samples. The load frame is a servo-hydraulic type designed to function in a closed loop configuration under computer control. The system can perform non-cyclic, tension, compression and flexure testing and cyclic fatigue tests. The system is comprised of two parts: * The Load Frame and * The Control System. Load Frame The Load Frame (figure 1) is a cross-head assembly which includes a single moving grip, a stationary grip and LVDT position sensor. It can generate up to 25 kN (5.5 kip) of force in the sample under test and can

178

Load management and the La Vereda passive solar community  

SciTech Connect

Reviewed are preliminary data available from some of the passive solar homes now operational at the La Vereda subdivision in Santa Fe, New Mexico. The major emphasis is Load Management - an electric utility term pertaining to when and how much energy is used by the customer. A customer's home is considered to be Load Managed when its major demands for electricity occur at times during the day when the utility has surplus generation capacity. For most utilities this surplus occurs during the night and is referred to as the off-peak period. Compared to conventional electric homes, the La Vereda passive solar homes are Naturally Load Managed because most of their backup heating requirements occur during the utility's off-peak period. Naturally Load Managed homes like these allow the backup heating system to operate freely whenever the space needs heat. Load data from six La Vereda homes are compared to similar data from 1) a group of nonsolar super-insulated total electric homes, and 2) the utility's winter system peak day load profile. The comparison verifies the Natural Load Management characteristics of the well-designed passive solar home. The free operation of the backup heating system, especially during cloudy or severe weather, can reduce the Natural Load Management characteristics of the La Verda homes. Is it possible to Force Load Management on a home, regardless of weather conditions and still guarantee that all space heating requirements are satisfied with off-peak energy. One home at La Vereda is discussed that has an experimental Forced Load Management backup heating system designed to use energy only during the utility's off-peak period. Load data from this home is presented and compared to other homes at La Verda.

Pyde, S.E.

1981-01-01T23:59:59.000Z

179

Clean Cities: Clean Cities Reference Materials  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Materials to Reference Materials to someone by E-mail Share Clean Cities: Clean Cities Reference Materials on Facebook Tweet about Clean Cities: Clean Cities Reference Materials on Twitter Bookmark Clean Cities: Clean Cities Reference Materials on Google Bookmark Clean Cities: Clean Cities Reference Materials on Delicious Rank Clean Cities: Clean Cities Reference Materials on Digg Find More places to share Clean Cities: Clean Cities Reference Materials on AddThis.com... Coordinator Basics Clean Cities Program Structure Reference Materials Technical Support Fundraising Redesignation Outreach Education & Webinars Meetings Reporting Contacts Clean Cities Reference Materials Use these reference materials-including quick-reference documents, publications, websites, and the Clean Cities Coalition Wiki-to develop

180

NETL: Reference Shelf - Techline Archive  

NLE Websites -- All DOE Office Websites (Extended Search)

NETL Oil & Natural Gas Technologies Reference Shelf NETL Oil & Natural Gas Technologies Reference Shelf Archive Reports 2012: December, 2012 Final Project Report DE-NT0006554 GIS- and Web-based Water Resource Geospatial Infrastructure for Oil Shale Development [PDF-14.6MB] November, 2012 Final Project Report 08121-2902-02 Technologies of the Future for Pipeline Monitoring and Inspection [PDF-2.47MB] November, 2012 Final Project Report 07122-22 Petrophysical Studies of Unconventional Gas Reservoirs Using High-resolution Rock Imaging [PDF-27.7MB] November, 2012 Final Project Report 08122-35 The Environmentally Friendly Drilling Systems Program [PDF-4.33] October, 2012 Final Project Report DE-FE0003537 Next Generation Surfactants for Improved Chemical Flooding Technology [PDF-1.91MB] October, 2012 Final Project Report 08123-02 Field Demonstration of Alkaline Surfactant Polymer Floods in Mature Oil Reservoirs Brookshire Dome, Texas [PDF-5.06MB]

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

The Consumption of Reference Resources  

E-Print Network (OSTI)

Under the operational restriction of the U(1)-superselection rule, states that contain coherences between eigenstates of particle number constitute a resource. Such resources can be used to facilitate operations upon systems that otherwise cannot be performed. However, the process of doing this consumes reference resources. We show this explicitly for an example of a unitary operation that is forbidden by the U(1)-superselection rule.

G. A. White; J. A. Vaccaro; H. M. Wiseman

2008-11-22T23:59:59.000Z

182

HANFORD WASTE MINERALOGY REFERENCE REPORT  

Science Conference Proceedings (OSTI)

This report lists the observed mineral phases present in the Hanford tanks. This task was accomplished by performing a review of numerous reports that used experimental techniques including, but not limited to: x-ray diffraction, polarized light microscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, electron energy loss spectroscopy, and particle size distribution analyses. This report contains tables that can be used as a quick reference to identify the crystal phases observed in Hanford waste.

DISSELKAMP RS

2010-06-29T23:59:59.000Z

183

HANFORD WASTE MINEROLOGY REFERENCE REPORT  

Science Conference Proceedings (OSTI)

This report lists the observed mineral phase phases present in the Hanford tanks. This task was accomplished by performing a review of numerous reports using experimental techniques including, but not limited to: x-ray diffraction, polarized light microscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, electron energy loss spectroscopy, and particle size distribution analyses. This report contains tables that can be used as a quick reference to identify the crystal phases present observed in Hanford waste.

DISSELKAMP RS

2010-06-18T23:59:59.000Z

184

514 ASHRAE Transactions: Symposia Design cooling load calculation methods are, by the  

E-Print Network (OSTI)

514 ASHRAE Transactions: Symposia ABSTRACT Design cooling load calculation methods are test. In the tests proposed here, the ASHRAE heat balance method is used as a reference model. Details of confidence in load calculation methods and the computer implementations that they use. ASHRAE has a long

185

International Energy Outlook - Chapter References  

Gasoline and Diesel Fuel Update (EIA)

Chapter References Chapter References International Energy Outlook 2004 Chapter References World Energy and Economic Outlook 1. D.F. Barnes et al., “Tackling the Rural Energy Problem in Developing Countries,” Finance & Development, Vol. 34, No. 2 (June 1997), pp. 11-15. 2. A. Kirby, “Russia’s Climate Tussle Spins On,” BBC News Online (December 4, 2003). 3. A.C. Revkin, “Into Thin Air: Kyoto Accord May Not Die (or Matter),” The New York Times (December 4, 2003), p. A6. 4. The White House, Office of the Press Secretary, “President Announces Clear Skies & Global Climate Change Initiatives” (Press Release, February 14, 2002), web site www.whitehouse.gov/news/ releases/2002/02/20020214-5.html. 5. Energy Information Administration, Annual Energy Outlook 2004, DOE/EIA-0383(2004) (Washington, DC, January 2004); and Global Insight, Inc., World Overview (Lexington, MA, September 2003). India’s GDP growth rates were adjusted downward, based on the judgment of EIA analysts.

186

Microgrid cyber security reference architecture.  

SciTech Connect

This document describes a microgrid cyber security reference architecture. First, we present a high-level concept of operations for a microgrid, including operational modes, necessary power actors, and the communication protocols typically employed. We then describe our motivation for designing a secure microgrid; in particular, we provide general network and industrial control system (ICS)-speci c vulnerabilities, a threat model, information assurance compliance concerns, and design criteria for a microgrid control system network. Our design approach addresses these concerns by segmenting the microgrid control system network into enclaves, grouping enclaves into functional domains, and describing actor communication using data exchange attributes. We describe cyber actors that can help mitigate potential vulnerabilities, in addition to performance bene ts and vulnerability mitigation that may be realized using this reference architecture. To illustrate our design approach, we present a notional a microgrid control system network implementation, including types of communica- tion occurring on that network, example data exchange attributes for actors in the network, an example of how the network can be segmented to create enclaves and functional domains, and how cyber actors can be used to enforce network segmentation and provide the neces- sary level of security. Finally, we describe areas of focus for the further development of the reference architecture.

Veitch, Cynthia K.; Henry, Jordan M.; Richardson, Bryan T.; Hart, Derek H.

2013-07-01T23:59:59.000Z

187

Building Technologies Office: Commercial Reference Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Reference Commercial Reference Buildings to someone by E-mail Share Building Technologies Office: Commercial Reference Buildings on Facebook Tweet about Building Technologies Office: Commercial Reference Buildings on Twitter Bookmark Building Technologies Office: Commercial Reference Buildings on Google Bookmark Building Technologies Office: Commercial Reference Buildings on Delicious Rank Building Technologies Office: Commercial Reference Buildings on Digg Find More places to share Building Technologies Office: Commercial Reference Buildings on AddThis.com... About Take Action to Save Energy Activities 179d Tax Calculator Advanced Energy Design Guides Advanced Energy Retrofit Guides Building Energy Data Exchange Specification Buildings Performance Database Data Centers Energy Asset Score

188

References and Notes for Astatine ( At )  

Science Conference Proceedings (OSTI)

... Version References and Notes for Astatine ( At ). Ref. ID, Reference, M64a, R. McLaughlin, J. Opt. Soc. Am. 54, 965 (1964).

189

FAQS Reference Guide - Transportation and Traffic Management...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Transportation and Traffic Management FAQS Reference Guide - Transportation and Traffic Management This reference guide addresses the competency statements in the September 2002...

190

MHK Reference Model: Relevance to Computer Simulation  

NLE Websites -- All DOE Office Websites (Extended Search)

July 9 th , 2012 SAND Number: 2012-5508P MHK Reference Model: Relevance to Computer Simulation Reference Model Partners Oregon State University NNMREC University of...

191

Category:Water References | Open Energy Information  

Open Energy Info (EERE)

Water References Jump to: navigation, search Pages in category "Water References" This category contains only the following page. A Assessment and Mapping of the Riverine...

192

Reference Inflow Characterization for River Resource Reference Model (RM2)  

DOE Green Energy (OSTI)

Sandia National Laboratory (SNL) is leading an effort to develop reference models for marine and hydrokinetic technologies and wave and current energy resources. This effort will allow the refinement of technology design tools, accurate estimates of a baseline levelized cost of energy (LCoE), and the identification of the main cost drivers that need to be addressed to achieve a competitive LCoE. As part of this effort, Oak Ridge National Laboratory was charged with examining and reporting reference river inflow characteristics for reference model 2 (RM2). Published turbulent flow data from large rivers, a water supply canal and laboratory flumes, are reviewed to determine the range of velocities, turbulence intensities and turbulent stresses acting on hydrokinetic technologies, and also to evaluate the validity of classical models that describe the depth variation of the time-mean velocity and turbulent normal Reynolds stresses. The classical models are found to generally perform well in describing river inflow characteristics. A potential challenge in river inflow characterization, however, is the high variability of depth and flow over the design life of a hydrokinetic device. This variation can have significant effects on the inflow mean velocity and turbulence intensity experienced by stationary and bottom mounted hydrokinetic energy conversion devices, which requires further investigation, but are expected to have minimal effects on surface mounted devices like the vertical axis turbine device designed for RM2. A simple methodology for obtaining an approximate inflow characterization for surface deployed devices is developed using the relation umax=(7/6)V where V is the bulk velocity and umax is assumed to be the near-surface velocity. The application of this expression is recommended for deriving the local inflow velocity acting on the energy extraction planes of the RM2 vertical axis rotors, where V=Q/A can be calculated given a USGS gage flow time-series and stage vs. cross-section area rating relationship.

Neary, Vincent S [ORNL

2011-12-01T23:59:59.000Z

193

Load Management: Opportunity or Calamity?  

E-Print Network (OSTI)

After the change in the economics of generating electricity which took place in 1973, many utilities are examining options to hold down their costs. One fact which is clear is that the difference between peak and off peak generating costs is much larger now than prior to 1973. Utilities are examining two options which can be termed load management. One option is to control discretionary loads during peak periods. Cycling of residential water heaters or shutting off industrial electric furnaces during peak periods are both examples of load control which lower the costs borne by the utility. The other option is the use of seasonal surcharges or time-of-day rates to induce customers to alter their usage patterns. Both these load management options focus on reducing utility costs overall without regard to the cost to the consumers affected by the load management options. The issue, then, is whether industrial customers can find opportunities to lower their costs under load management.

Males, R.; Hassig, N.

1981-01-01T23:59:59.000Z

194

Dynamic load balancing of applications  

DOE Patents (OSTI)

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated.

Wheat, Stephen R. (Albuquerque, NM)

1997-01-01T23:59:59.000Z

195

Dynamic load balancing of applications  

DOE Patents (OSTI)

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers is disclosed. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated. 13 figs.

Wheat, S.R.

1997-05-13T23:59:59.000Z

196

Alaska Village Electric Load Calculator  

DOE Green Energy (OSTI)

As part of designing a village electric power system, the present and future electric loads must be defined, including both seasonal and daily usage patterns. However, in many cases, detailed electric load information is not readily available. NREL developed the Alaska Village Electric Load Calculator to help estimate the electricity requirements in a village given basic information about the types of facilities located within the community. The purpose of this report is to explain how the load calculator was developed and to provide instructions on its use so that organizations can then use this model to calculate expected electrical energy usage.

Devine, M.; Baring-Gould, E. I.

2004-10-01T23:59:59.000Z

197

High-Power Rf Load  

DOE Patents (OSTI)

A compact high-power RF load comprises a series of very low Q resonators, or chokes [16], in a circular waveguide [10]. The sequence of chokes absorb the RF power gradually in a short distance while keeping the bandwidth relatively wide. A polarizer [12] at the input end of the load is provided to convert incoming TE.sub.10 mode signals to circularly polarized TE.sub.11 mode signals. Because the load operates in the circularly polarized mode, the energy is uniformly and efficiently absorbed and the load is more compact than a rectangular load. Using these techniques, a load having a bandwidth of 500 MHz can be produced with an average power dissipation level of 1.5 kW at X-band, and a peak power dissipation of 100 MW. The load can be made from common lossy materials, such as stainless steel, and is less than 15 cm in length. These techniques can also produce loads for use as an alternative to ordinary waveguide loads in small and medium RF accelerators, in radar systems, and in other microwave applications. The design is easily scalable to other RF frequencies and adaptable to the use of other lossy materials.

Tantawi, Sami G. (San Mateo, CA); Vlieks, Arnold E. (Livermore, CA)

1998-09-01T23:59:59.000Z

198

PVWatts Version 1 Technical Reference  

DOE Green Energy (OSTI)

The NREL PVWatts(TM) calculator is a web application developed by the National Renewable Energy Laboratory (NREL) that estimates the electricity production of a grid-connected photovoltaic system based on a few simple inputs. PVWatts combines a number of sub-models to predict overall system performance, and makes several hidden assumptions about performance parameters. This technical reference details the individual sub-models, documents assumptions and hidden parameters, and explains the sequence of calculations that yield the final system performance estimation.

Dobos, A. P.

2013-10-01T23:59:59.000Z

199

Emergency Responder Radioactive Material Quick Reference Sheet...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Transportation Emergency Preparedness Program (TEPP) Emergency Responder Radioactive Material Quick Reference Sheet...

200

Static identification of delinquent loads  

E-Print Network (OSTI)

The effective use of processor caches is crucial to the performance of applications. It has been shown that cache misses are not evenly distributed throughout a program. In applications running on RISC-style processors, a small number of delinquent load instructions are responsible for most of the cache misses. Identification of delinquent loads is the key to the success of many cache optimization and prefetching techniques. In this paper, we propose a method for identifying delinquent loads that can be implemented at compile time. Our experiments over eighteen benchmarks from the SPEC suite shows that our proposed scheme is stable across benchmarks, inputs, and cache structures, identifying an average of 10 % of the total number of loads in the benchmarks we tested that account for over 90 % of all data cache misses. As far as we know, this is the first time a technique for static delinquent load identification with such a level of precision and coverage has been reported. While comparable techniques can also identify load instructions that cover 90 % of all data cache misses, they do so by selecting over 50 % of all load instructions in the code, resulting in a high number of false positives. If basic block profiling is used in conjunction with our heuristic, then our results show that it is possible to pin down just 1.3 % of the load instructions that account for 82 % of all data cache misses. 1.

Vlad-mihai Panait; Amit Sasturkar Ý

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

LOAD FORECASTING Eugene A. Feinberg  

E-Print Network (OSTI)

's electricity price forecasting model, produces forecast of gas demand consistent with electric load. #12Gas demand Council's Market Price of Electricity Forecast Natural GasDemand Electric Load Aggregating Natural between the natural gas and electricity and new uses of natural gas emerge. T natural gas forecasts

Feinberg, Eugene A.

202

Subsurface Knowledge Reference Page | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Subsurface Knowledge Reference Page Subsurface Knowledge Reference Page Subsurface Knowledge Reference Page The below listing provides additional references related to Subsurface & Groundwater Remediation. The references are categorized by documents types (e.g., Strategic Plans, Groundwater Plume Map Booklets, etc.) and under each "document type", there is a list of documents and/or hyperlinks to a reference. The Subsurface Knowledge Reference Page will continue to reflect additional information as it is identified. Strategic Plans Scientific Opportunities to Reduce Risk in Groundwater and Soil Remediation Scientific Opportunities for Monitoring at Environmental Remediation Sites (SOMERS) Groundwater Plume Map Booklets Groundwater Contamination and Treatment at Department of Energy Sites -

203

New Robust References! | OpenEI Community  

Open Energy Info (EERE)

New Robust References! New Robust References! Home > Groups > OpenEI Community Central Jweers's picture Submitted by Jweers(83) Contributor 7 August, 2013 - 18:23 citation citing developer formatting reference Semantic Mediawiki wiki Check out the new Reference Form. Adding a reference object to OpenEI using this form is the most complete way to cite a reference. After providing the name of your reference, the form will ask for your document type. Depending on what you choose, it will ask for the information necessary to build the proper MLA citation for the reference. This citation is then available semantically as a property of the reference and can be embedded in other pages! The Cite template was developed to help with this. You can site a reference by including {{Cite|Asimov's Story|I,_Robot}}, where I,_Robot

204

Wind load reduction for heliostats  

DOE Green Energy (OSTI)

This report presents the results of wind-tunnel tests supported through the Solar Energy Research Institute (SERI) by the Office of Solar Thermal Technology of the US Department of Energy as part of the SERI research effort on innovative concentrators. As gravity loads on drive mechanisms are reduced through stretched-membrane technology, the wind-load contribution of the required drive capacity increases in percentage. Reduction of wind loads can provide economy in support structure and heliostat drive. Wind-tunnel tests have been directed at finding methods to reduce wind loads on heliostats. The tests investigated primarily the mean forces, moments, and the possibility of measuring fluctuating forces in anticipation of reducing those forces. A significant increase in ability to predict heliostat wind loads and their reduction within a heliostat field was achieved.

Peterka, J.A.; Hosoya, N.; Bienkiewicz, B.; Cermak, J.E.

1986-05-01T23:59:59.000Z

205

2005 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE  

U.S. Energy Information Administration (EIA) Indexed Site

Page 1 Page 1 2012 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE Kerosene Line No. Sold directly to consumers for: 1 Residential Use (Non-Farm): * Backup generator * Home heating and cooking * Personal lawn equipment * EXCLUDE: Apartment buildings and Farmhouses 2 Commercial Use: * Apartment building * Bank * Casino * Church * College/School/Institution * Department/Retail store * Environmental clean-up service * Flushing fuel lines * Forestry service * Golf course * Government (Federal, State, local, and district; INCLUDE fuel used in vehicles) * Hazardous waste company * Hospital * Hotel/Motel * Landfill site government owned * Landscaping * Laundry company * Lumber yard that sells the lumber * Medical service * Port Authority/publicly owned port or loading dock

206

NETL: Gasification Systems Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Shelf Shelf Gasification Systems Reference Shelf TABLE OF CONTENTS Brochures Conferences and Workshops Gasification Systems Projects National Map Gasification Systems Projects and Performers Gasification Systems Project Portfolio Gasifipedia Multi-phase Flow with Interphase eXchange (MFIX) Patents Program Presentations Project Information Projects Summary Table by State Solicitations Systems and Industry Analyses Studies Technical Presentations & Papers Technology Readiness Assessment (Comprehensive Report | Overview Report) Video, Images & Photos Gasification Plant Databases CD Icon Request Gasification Technologies Information on a CD. Gasification RSS Feed Subscribe to the Gasification RSS Feed to follow website updates. LinkedIn DOE Gasification Program Group Subscribe to the LinkedIn DOE Gasification Program group for more information and discussion.

207

The Nuclear Science References Database  

E-Print Network (OSTI)

The Nuclear Science References (NSR) database together with its associated Web interface, is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 210,000 articles since the beginning of nuclear science. The weekly-updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center http://www.nndc.bnl.gov/nsr and the International Atomic Energy Agency http://www-nds.iaea.org/nsr.

Pritychenko, B; Singh, B; Totans, J

2013-01-01T23:59:59.000Z

208

NUCLEAR SCIENCE REFERENCES CODING MANUAL  

Science Conference Proceedings (OSTI)

This manual is intended as a guide for Nuclear Science References (NSR) compilers. The basic conventions followed at the National Nuclear Data Center (NNDC), which are compatible with the maintenance and updating of and retrieval from the Nuclear Science References (NSR) file, are outlined. The NSR database originated at the Nuclear Data Project (NDP) at Oak Ridge National Laboratory as part of a project for systematic evaluation of nuclear structure data.1 Each entry in this computer file corresponds to a bibliographic reference that is uniquely identified by a Keynumber and is describable by a Topic and Keywords. It has been used since 1969 to produce bibliographic citations for evaluations published in Nuclear Data Sheets. Periodic additions to the file were published as the ''Recent References'' issues of Nuclear Data Sheets prior to 2005. In October 1980, the maintenance and updating of the NSR file became the responsibility of the NNDC at Brookhaven National Laboratory. The basic structure and contents of the NSR file remained unchanged during the transfer. In Chapter 2, the elements of the NSR file such as the valid record identifiers, record contents, and text fields are enumerated. Relevant comments regarding a new entry into the NSR file and assignment of a keynumber are also given in Chapter 2. In Chapter 3, the format for keyword abstracts is given followed by specific examples; for each TOPIC, the criteria for inclusion of an article as an entry into the NSR file as well as coding procedures are described. Authors preparing Keyword abstracts either to be published in a Journal (e.g., Nucl. Phys. A) or to be sent directly to NNDC (e.g., Phys. Rev. C) should follow the illustrations in Chapter 3. The scope of 1See W.B.Ewbank, ORNL-5397 (1978). the literature covered at the NNDC, the categorization into Primary and Secondary sources, etc., is discussed in Chapter 4. Useful information regarding permitted character sets, recommended abbreviations, etc., is given in the Appendices. The NSR database has been in existence for decades, and responsibility for its upkeep has passed through many hands. Those familiar with the contents of NSR will note that not all of the formats and conventions discussed in this manual have always been adhered to. In recent years, however, these conventions have been followed fairly consistently, and it is expected that the preparation of new entries will follow these guidelines. The most up-to-date information about NSR contents and policies can be found at the NSR web site: http://www.nndc.bnl.gov/nsr. This manual is an update to BNL-NCS-51800 (Rev. 08/96) by S. Ramavataram and C.L. Dunford. Discussions with Mark Kellett of the IAEA are gratefully acknowledged, as are comments and suggestions from the NNDC staff and members of the U.S. Nuclear Data Program. This manuscript has been authored by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH1-886 with the U.S.Department of Energy.

WINCHELL,D.F.

2007-04-01T23:59:59.000Z

209

load data | OpenEI Community  

Open Energy Info (EERE)

51 51 Varnish cache server Home Groups Community Central Green Button Applications Developer Utility Rate FRED: FRee Energy Database More Public Groups Private Groups Features Groups Blog posts Content Stream Documents Discussions Polls Q & A Events Notices My stuff Energy blogs 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142234851 Varnish cache server load data Home Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 12:03 Commercial and Residential Hourly Load Data Now Available on OpenEI! building load building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL Files: application/zip icon System Advisor Model Tool for Downloading Load Data

210

Commercial and Residential Hourly Load Profiles for all TMY3 Locations in  

Open Energy Info (EERE)

and Residential Hourly Load Profiles for all TMY3 Locations in and Residential Hourly Load Profiles for all TMY3 Locations in the United States Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Hourly load profiles are available for over all TMY3 locations in the United States here. Browse files in this dataset, accessible as individual files and as commercial and residential downloadable ZIP files. This dataset is approximately 4.8GiB compressed or 19GiB uncompressed. July 2nd, 2013 update: Residential High and Low load files have been updated from 366 days in a year for leap years to the more general 365 days in a normal year.

211

Spinning Reserve from Responsive Load  

SciTech Connect

As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host a spinning reserve test. The Tennessee Valley Authority (TVA) supplied real-time metering and monitoring expertise to record total hotel load during both normal operations and testing. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. The load drop was very rapid, essentially as fast as the 2 second metering could detect.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL; Laughner, T [Tennessee Valley Authority (TVA); Morris, K [Tennessee Valley Authority (TVA)

2009-01-01T23:59:59.000Z

212

An Analysis of a Combined Hardware-software Mechanism for Speculative Loads  

E-Print Network (OSTI)

This paper describes a simple hardware mechanism and related compiler support for softwarecontrolled speculative loads. The compiler issues speculative load instructions based on anticipated data references and the ability of the memory system to hide memory latency in high-performance processors. The architectural support for such a mechanism is simple and minimal, yet handles faults gracefully. We have simulated three speculative load mechanisms based on a MIPS processor and a detailed memory system. The results of scientific kernel loops indicate that speculative load techniques can hide memory latency effectively.

Stefanos Damianakis; Kai Li; Anne Rogers

1994-01-01T23:59:59.000Z

213

Advanced nonintrusive load monitoring system  

E-Print Network (OSTI)

There is a need for flexible, inexpensive metering technologies that can be deployed in many different monitoring scenarios. Individual loads may be expected to compute information about their power consumption. Utility ...

Wichakool, Warit, 1977-

2011-01-01T23:59:59.000Z

214

OpenEI - building load  

Open Energy Info (EERE)

are given by a location defined by the Typical Meteorological Year (TMY) for which the weather data was collected. Commercial load data is sorted by the (TMY) site as a...

215

Permanent Load Shift Control Strategies  

NLE Websites -- All DOE Office Websites (Extended Search)

of Permanent Load Shifting for HVAC and other storage assets as it relates to summer on-peak demand, how it can be dynamically and autonomously controlled, and its relationship...

216

Building load control and optimization  

E-Print Network (OSTI)

Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on load control by improving the operations in existing building HVAC ...

Xing, Hai-Yun Helen, 1976-

2004-01-01T23:59:59.000Z

217

Definition: Real-Time Load Measurement And Management | Open Energy  

Open Energy Info (EERE)

Management Management Jump to: navigation, search Dictionary.png Real-Time Load Measurement And Management This function provides real-time measurement of customer consumption and management of load through Advanced Metering Infrastructure (AMI) systems (smart meters, two-way communications) and embedded appliance controllers that help customers make informed energy use decisions via real-time price signals, time-of-use (TOU) rates, and service options.[1] Related Terms advanced metering infrastructure, time-of-use pricing, smart grid References ↑ SmartGrid.gov 'Description of Functions' An in LikeLike UnlikeLike You like this.Sign Up to see what your friends like. line Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Real-Time_Load_Measurement_And_Management&oldid=493115

218

Forecasting electricity load demand: analysis of the 2001 rationing period  

E-Print Network (OSTI)

CEPEL e UENF. Abstract. This paper studies the electricity load demand behavior during the 2001 rationing period, which was implemented because of the Brazilian energetic crisis. The hourly data refers to a utility situated in the southeast of the country. We use the model proposed by Soares and Souza (2003), making use of generalized long memory to model the seasonal behavior of the load. The rationing period is shown to have imposed a structural break in the series, decreasing the load at about 20%. Even so, the forecast accuracy is decreased only marginally, and the forecasts rapidly readapt to the new situation. The forecast errors from this model also permit verifying the public response to pieces of information released regarding the crisis.

Leonardo Rocha Souza; Lacir Jorge Soares; Leonardo Rocha Souza; Epge Fundação; Getúlio Vargas; Lacir Jorge Soares

2003-01-01T23:59:59.000Z

219

ILC cryogenic systems reference design  

SciTech Connect

A Global Design Effort (GDE) began in 2005 to study a TeV scale electron-positron linear accelerator based on superconducting radio-frequency (RF) technology, called the International Linear Collider (ILC). In early 2007, the design effort culminated in a reference design for the ILC, closely based on the earlier TESLA design. The ILC will consist of two 250 GeV linacs, which provide positron-electron collisions for high energy physics research. The particle beams will be accelerated to their final energy in superconducting niobium RF cavities operating at 2 kelvin. At a length of about 12 km each, the main linacs will be the largest cryogenic systems in the ILC. Positron and electron sources, damping rings, and beam delivery systems will also have a large number and variety of other superconducting RF cavities and magnets, which require cooling at liquid helium temperatures. Ten large cryogenic plants with 2 kelvin refrigeration are envisioned to cool the main linacs and the electron and positron sources. Three smaller cryogenic plants will cool the damping rings and beam delivery system components predominately at 4.5 K. This paper describes the cryogenic systems concepts for the ILC.

Peterson, T.J.; Geynisman, M.; Klebaner, A.; Theilacker, J.; /Fermilab; Parma, V.; Tavian, L.; /CERN

2008-01-01T23:59:59.000Z

220

Argon Purification Reference and Recommendation  

Science Conference Proceedings (OSTI)

This engineering note is a reference for future consideration on the purification of argon. The original concern was for the possibility of argon contamination from components in the cryostats over long-term storage. An argon purification system could also be useful for purifying the contents of the argon dewar. The general conclusion is that most of the systems researched are too expensive at this time, but the recommended choice would be Centorr Furnaces. There were three basic types of purification systems which were to be considered. The first was the molecular sieve. This method would have been the preferred one, because it was claimed that it could purify liquid argon, removing liquid oxygen from the argon. However, none of the commercial companies researched provided this type of purification for use with liquid argon. Most companies said that this type of purification was impossible, and tests at IB-4 confirmed this. The second system contained a copper oxide to remove gaseous oxygen from argon gas. The disadvantage of this system wass that the argon had to be heated to a gas, and then cooled back down to liquid. The third system was similar to the second, except that it used tungsten or another material like titanium. This system also needed to heat the argon to gas, however the advantage of this system was that it supposedly removed all contaminants, that is, everything except for inert gases. Of the three systems, the third is the type manufactured by Centorr Furnaces, which uses a titanium charge.

Wu, J.; /Fermilab

1991-05-23T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Generating Referring Expressions that Involve Gradable Properties  

Science Conference Proceedings (OSTI)

This article examines the role of gradable properties in referring expressions from the perspective of natural language generation. First, we propose a simple semantic analysis of vague descriptions (i.e., referring expressions that contain gradable ...

Kees van Deemter

2006-06-01T23:59:59.000Z

222

Forecasting with Reference to a Specific Climatology  

Science Conference Proceedings (OSTI)

Seasonal forecasts are most commonly issued as anomalies with respect to some multiyear reference period. However, different seasonal forecasting centers use different reference periods. This paper shows that for near-surface temperature, ...

Emily Wallace; Alberto Arribas

2012-11-01T23:59:59.000Z

223

NIST Standard Reference Material/SRM product  

Science Conference Proceedings (OSTI)

*. Bookmark and Share. How do I order/price a NIST Standard Reference Material/SRM product? Ordering information is ...

2012-11-26T23:59:59.000Z

224

Environment/Climate Standard Reference Materials Portal  

Science Conference Proceedings (OSTI)

... more. Reference Materials and Standards for Fossil Fuels, Electric Utility Emissions, and Coal Combustion By-Products ...

2012-12-27T23:59:59.000Z

225

SPC/E Water Reference Calculations  

Science Conference Proceedings (OSTI)

SPC/E Water Reference Calculations - Ewald Summation. In ... 5. Sample Configurations of SPC/E Water Molecules. Four ...

2013-09-16T23:59:59.000Z

226

Bioscience & Health Standard Reference Materials Portal  

Science Conference Proceedings (OSTI)

... Our goal is to develop advanced measurement tools and standards for measuring ... see all Bioscience & Health Standard Reference Materials ...

2013-08-08T23:59:59.000Z

227

Reference framework for E-participation projects  

Science Conference Proceedings (OSTI)

Accommodating the various requirements from distinct perspectives in e-participation calls for a holistic engineering approach for e-participation systems analysis and design. This paper presents research results towards a reference framework for e-participation ... Keywords: E-participation, reference framework, reference model

Sabrina Scherer; Maria A. Wimmer

2011-08-01T23:59:59.000Z

228

Load transfer coupling regression curve fitting for distribution load forecasting  

SciTech Connect

The planning of distribution facilities requires forecasts of future substation and feeder loads. Extrapolation based on a curve fit to past annual peak loads is currently the most popular manner of accomplishing this forecast. Curve fitting suffers badly from data shifts caused by switching as loads are routinely moved from one substation to another during the course of utility operations. This switching contaminates the data, reducing forecast accuracy. A new regression application reduces error due to these transfers by over an order of magnitude. A key to the usefulness of this method is that the amount of the transfer, and its direction (whether it was to or from a substation), is not a required input. The new technique, aspects of computer implementation of it, and a series of tests showing its advantage over normal multiple regression methods are given.

Willis, H.L.; Powell, R.W.

1984-05-01T23:59:59.000Z

229

Realizing load reduction functions by aperiodic switching of load groups  

SciTech Connect

This paper investigates the problem of scheduling ON/OFF switching of residential appliances under the control of a Load Management System (LMS). The scheduling process is intended to reduce the controlled appliances` power demand in accordance with a predefined load reduction profile. To solve this problem, a solution approach, based on the methodology of Pulse Width Modulation (PWM), is introduced. This approach provides a flexible mathematical basis for studying different aspects of the scheduling problem. The conventional practices in this area are shown to be special cases of the PWM technique. By applying the PWM-based technique to the scheduling problem, important classes of scheduling errors are identified and analytical expressions describing them are derived. These expressions are shown to provide sufficient information to compensate for the errors. Detailed simulations of load groups` response to switching actions are use to support conclusions of this study.

Navid-Azarbaijani, N. [McGill Univ., Montreal, Quebec (Canada). Dept. of Electrical Engineering; Banakar, M.H. [CAE Electronics Ltd., St. Laurent, Quebec (Canada)

1996-05-01T23:59:59.000Z

230

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network (OSTI)

PSLF that incorporates motor  A?C, ZIP, and electronic load the fractions motors A?C, ZIP, and electronic loads.    Usethat incorporates motor  A?C, ZIP, and  electronic load 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

231

load profile | OpenEI Community  

Open Energy Info (EERE)

load profile Home Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 13:03 Commercial and Residential Hourly Load Data Now Available on OpenEI building load building...

232

Monthly Crustal Loading Corrections for Satellite Altimetry  

Science Conference Proceedings (OSTI)

Satellite altimeter measurements of sea surface height include a small contribution from vertical motion of the seafloor caused by crustal loading. Loading by ocean tides is routinely allowed for in altimeter data processing. Here, loading by ...

R. D. Ray; S. B. Luthcke; T. van Dam

2013-05-01T23:59:59.000Z

233

Peak load management: Potential options  

SciTech Connect

This report reviews options that may be alternatives to transmission construction (ATT) applicable both generally and at specific locations in the service area of the Bonneville Power Administration (BPA). Some of these options have potential as specific alternatives to the Shelton-Fairmount 230-kV Reinforcement Project, which is the focus of this study. A listing of 31 peak load management (PLM) options is included. Estimated costs and normalized hourly load shapes, corresponding to the respective base load and controlled load cases, are considered for 15 of the above options. A summary page is presented for each of these options, grouped with respect to its applicability in the residential, commercial, industrial, and agricultural sectors. The report contains comments on PLM measures for which load shape management characteristics are not yet available. These comments address the potential relevance of the options and the possible difficulty that may be encountered in characterizing their value should be of interest in this investigation. The report also identifies options that could improve the efficiency of the three customer utility distribution systems supplied by the Shelton-Fairmount Reinforcement Project. Potential cogeneration options in the Olympic Peninsula are also discussed. These discussions focus on the options that appear to be most promising on the Olympic Peninsula. Finally, a short list of options is recommended for investigation in the next phase of this study. 9 refs., 24 tabs.

Englin, J.E.; De Steese, J.G.; Schultz, R.W.; Kellogg, M.A.

1989-10-01T23:59:59.000Z

234

Form:Reference | Open Energy Information  

Open Energy Info (EERE)

Form Form Edit History Facebook icon Twitter icon » Form:Reference Jump to: navigation, search Input the title of a Reference below. If the reference already exists, you will be able to edit its information. Add/Edit Reference The text entered into this field will be used as the name of the reference; for example, the title of a book or name of the journal article. Example references Claritas Rise, Mars- Pre-Tharsis Magmatism? An Improved Equilibrium-Kinetics Speciation Algorithm For Redox Reactions In Variably Saturated Subsurface Flow Systems True-Temperature Determination Of Geothermal Reservoirs ... further results This form and reference requirements are based on the Council of Science Editors (CSE) (author-date) citation style. For more details about this

235

Commercial Reference Buildings | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Commercial Reference Buildings Jump to: navigation, search DOE developed Commercial Reference Buildings which provide descriptions for whole building analysis using EnergyPlus. There are 16 building types and three categories that apply to all building types. The commercial reference buildings were developed across 16 reference locations. Contents 1 Building Types 2 Construction Categories 3 Climate Zones Used to Create Reference Buildings 4 References Building Types DOE developed 16 Commercial Reference Building Types[1] , which represent approximately 70% of the commercial buildings in the U.S. [2]. Whole

236

Template:Reference | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Template Edit History Facebook icon Twitter icon » Template:Reference Jump to: navigation, search This is the Reference template. To define/cite a new reference using CSE citation format, please use the Reference form. Parameters Name - The name or title of the reference material Document_type - The type of reference material (allowable values) InfographicType - The type of infographic if Info Grahpic/Map/Chart is the selected Document_type ThesisDissertation - Determines thesis or dissertation (Thesis/Dissertation) Authors - Comma delimited list of people who authored the reference material (required for Books, Conference Papers and Proceedings, Journal

237

V-203: HP LoadRunner Multiple Bugs Let Remote Users Deny Service and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3: HP LoadRunner Multiple Bugs Let Remote Users Deny Service 3: HP LoadRunner Multiple Bugs Let Remote Users Deny Service and Execute Arbitrary Code V-203: HP LoadRunner Multiple Bugs Let Remote Users Deny Service and Execute Arbitrary Code July 26, 2013 - 3:31am Addthis PROBLEM: A remote user can execute arbitrary code on the target system. A remote user can cause denial of service conditions. PLATFORM: HP LoadRunner prior to 11.52 ABSTRACT: Multiple vulnerabilities were reported in HP LoadRunner. REFERENCE LINKS: Security Tracker Alert ID: 1028833 CVE-2013-2368 CVE-2013-2369 CVE-2013-2370 CVE-2013-4797 CVE-2013-4798 CVE-2013-4799 CVE-2013-4800 CVE-2013-4801 IMPACT ASSESSMENT: Medium DISCUSSION: Potential security vulnerabilities have been identified with HP LoadRunner. The vulnerabilities could be remotely exploited to allow execution of code

238

Evaluation of concrete masonry unit walls for lateral natural phenomena hazards loads  

Science Conference Proceedings (OSTI)

Older single-story facilities (Pre-1985 vintage) are commonly constructed of structural steel framing with concrete masonry unit (CMU) walls connected to columns and roof girders of the steel framing system. The CMU walls are designed for lateral wind and seismic loads (perpendicular to the wall) and transmit shear loads from the roof diaphragm to the foundation footings. The lateral loads normally govern their design. The structural framing system and the roof diaphragm system are straight forward when analyzing or upgrading the structure for NPH loads. Because of a buildings design vintage, probable use of empirical methodology, and poor design basis documentation (and record retention); it is difficult to qualify or upgrade CMU walls for lateral Natural Phenomena Hazards (NPH) loads in accordance with References 1, 2 and 3. This paper discusses three analytical approaches and/or techniques (empirical, working stress and yield line) to determine the collapse capacity of a laterally loaded CMU wall, and compares their results

Faires, W.E. Jr.

1996-03-08T23:59:59.000Z

239

Definition: Load | Open Energy Information  

Open Energy Info (EERE)

system.1 Related Terms power References Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline...

240

Building Energy Software Tools Directory: Load Express  

NLE Websites -- All DOE Office Websites (Extended Search)

graphical interface makes Load Express a powerful engineering tool with a very short learning curve. The "rookie" or experienced user can quickly and accurately perform load...

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Self-aligning biaxial load frame  

DOE Patents (OSTI)

An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed cross head, and by alignment and linear motion elements of one load assembly relative to the load frame. 3 figures.

Ward, M.B.; Epstein, J.S.; Lloyd, W.R.

1994-01-18T23:59:59.000Z

242

Decentralized customerlevel under frequency load shedding in...  

Open Energy Info (EERE)

enables the management of large groups of distributed loads under a single innovative control schemes to use the flexibility of electrical loads for power system purposes....

243

Method for loading resin beds  

DOE Patents (OSTI)

An improved method of preparing nuclear reactor fuel by carbonizing a uranium loaded cation exchange resin provided by contacting a H.sup.+ loaded resin with a uranyl nitrate solution deficient in nitrate, comprises providing the nitrate deficient solution by a method comprising the steps of reacting in a reaction zone maintained between about 145.degree.-200.degree. C, a first aqueous component comprising a uranyl nitrate solution having a boiling point of at least 145.degree. C with a second aqueous component to provide a gaseous phase containing HNO.sub.3 and a reaction product comprising an aqueous uranyl nitrate solution deficient in nitrate.

Notz, Karl J. (Oak Ridge, TN); Rainey, Robert H. (Knoxville, TN); Greene, Charles W. (Knoxville, TN); Shockley, William E. (Oak Ridge, TN)

1978-01-01T23:59:59.000Z

244

Commercial Reference Buildings | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Buildings » Research Projects » Commercial Reference Buildings » Research Projects » Commercial Reference Buildings Commercial Reference Buildings The U.S. Department of Energy (DOE), in conjunction with three of its national laboratories, developed commercial reference buildings, formerly known as commercial building benchmark models. These reference buildings play a critical role in the program's energy modeling software research by providing complete descriptions for whole building energy analysis using EnergyPlus simulation software. There are 16 building types that represent approximately 70% of the commercial buildings in the U.S., according to the report published by the National Renewable Energy Laboratory titled U.S. Department of Energy Commercial Reference Building Models of the National Building Stock. These

245

Existing Commercial Reference Buildings Constructed Before 1980 |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Existing Commercial Reference Buildings Constructed Before 1980 Existing Commercial Reference Buildings Constructed Before 1980 Existing Commercial Reference Buildings Constructed Before 1980 The files on this page contain commercial reference building models for existing buildings constructed before 1980, organized by building type and location. These U.S. Department of Energy (DOE) reference buildings are complete descriptions for whole building energy analysis. You can also return to a summary of building types and climate zones and information about other building vintages. These files are updated regularly. There are two versions of these files on this page. Version 1.3_5.0 was updated September 27, 2010 and Version 1.4_7.2 was updated November 13, 2012. You can also view related resources: an archive of past reference buildings files

246

PRB rail loadings shatter record  

Science Conference Proceedings (OSTI)

Rail transport of coal in the Powder River Basin has expanded, with a record 2,197 trains loaded in a month. Arch Coal's Thunder basin mining complex has expanded by literally bridging the joint line railway. The dry fork mine has also celebrated its safety achievements. 4 photos.

Buchsbaum, L.

2008-09-15T23:59:59.000Z

247

Automatic Electric Load Identification in  

E-Print Network (OSTI)

Abstract — A microgrid is the power system of choice for the electrification of rural areas in developing countries. It should be able to adapt to changing load situations without the need for specialists to change the configuration of the microgrid controller. This paper proposes a self-configuring microgrid management system that is able to adjust both generation and demand of the system, so that also in case of growing electricity demand the grid can still be operable by disconnecting unessential loads. A crucial task for the microgrid controller is to automatically identify the connected loads on the basis of their consumption behaviors. For this, a template-matching algorithm is proposed that is based on Dynamic Time Warping, which is primarily used in speech recognition. It has been found that for load profile analysis, simple signal features such as the number of rising edges or the aggregated energy consumption in a given time window is sufficient to describe the signal. In contrast to speech recognition, frequency domain analysis is not necessary.

Self-configuring Microgrids; Friederich Kupzog; Tehseen Zia; Adeel Abbas Zaidi

2009-01-01T23:59:59.000Z

248

On-line load relief control  

SciTech Connect

This paper describes the results of an investigation concerning the on-line prediction and enhancement of load relief. The effects of voltage fluctuation, system voltage profile control and generator voltage adjustment on load relief and load shedding operations during under-frequency transients are studied. The technique promoted in the paper may be used to reduce system spinning reserve or prospective load shedding.

Jovanovic, S.; Fox, B.; Thompson, J.G. (Queen' s Univ. of Belfast (United Kingdom))

1994-11-01T23:59:59.000Z

249

Load Forecasting for Modern Distribution Systems  

Science Conference Proceedings (OSTI)

Load forecasting is a fundamental activity for numerous organizations and activities within a utility, including planning, operations, and control. Transmission and Distribution (T&D) planning and design engineers use the load forecast to determine whether any changes and additions are needed to the electric system to satisfy the anticipated load. Other load forecast users include system operations, financial ...

2013-03-08T23:59:59.000Z

250

Load Forecast For use in Resource Adequacy  

E-Print Network (OSTI)

Load Forecast 2019 For use in Resource Adequacy Massoud Jourabchi #12;In today's presentation d l­ Load forecast methodology ­ Drivers of the forecast f i­ Treatment of conservation ­ Incorporating impact of weather ­ Forecast for 2019 #12;Regional Loads (MWA and MW)Regional Loads (MWA and MW

251

Evolving non-intrusive load monitoring  

Science Conference Proceedings (OSTI)

Non-intrusive load monitoring (NILM) identifies used appliances in a total power load according to their individual load characteristics. In this paper we propose an evolutionary optimization algorithm to identify appliances, which are modeled as on/off ... Keywords: NILM, evolution, evolutionary algorithm, knapsack problem, non-intrusive load monitoring

Dominik Egarter; Anita Sobe; Wilfried Elmenreich

2013-04-01T23:59:59.000Z

252

FACILITY MAINTENANCE MANAGEMENT QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Facility Facility Maintenance Management Qualification Standard Reference Guide NOVEMBER 2009 Table of Contents i FIGURES...................................................................................................................................... iv TABLES........................................................................................................................................ iv ACRONYMS ................................................................................................................................. v PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

253

ENVIRONMENTAL COMPLIANCE QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Environmental Environmental Compliance Qualification Standard Reference Guide DECEMBER 2011 Table of Contents i LIST OF FIGURES ..................................................................................................................... iii LIST OF TABLES ....................................................................................................................... iii ACRONYMS ................................................................................................................................ iv PURPOSE ...................................................................................................................................... 1 SCOPE ........................................................................................................................................... 1

254

ENVIRONMENTAL RESTORATION QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Restoration Qualification Standard Reference Guide NOVEMBER 2009 i Table of Contents i FIGURES...................................................................................................................................... iv TABLES........................................................................................................................................ iv ACRONYMS ................................................................................................................................. v PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

255

CRITICALITY SAFETY QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Criticality Criticality Safety Qualification Standard Reference Guide APRIL 2011 This page is intentionally blank. Table of Contents i FIGURES ...................................................................................................................................... iii PURPOSE ...................................................................................................................................... 1 SCOPE ........................................................................................................................................... 1 PREFACE ...................................................................................................................................... 1 ACKNOWLEDGEMENTS ......................................................................................................... 2

256

NIST Standard Reference Databases: Surface Data  

Science Conference Proceedings (OSTI)

... Standard Reference Data, NIST: 100 Bureau Drive, Stop 2300 Gaithersburg, MD 20899-2300 Tel: 301-975-2208 Fax: 301-926-0416. ... Surface Data. ...

2012-12-17T23:59:59.000Z

257

New Reference Standards for Digital Mammography  

Science Conference Proceedings (OSTI)

New Reference Standards for Digital Mammography. ... The NIST 100 kV tungsten anode x-ray unit and the Ritz primary standard free-air ionization ...

2013-03-13T23:59:59.000Z

258

A New Solar Irradiance Reference Spectrum  

NLE Websites -- All DOE Office Websites (Extended Search)

A New Solar Irradiance Reference Spectrum Pilewskie, Peter University of Colorado Fontenla, Juan LASP University of Colorado Harder, Jerry LASP University of Colorado Category:...

259

EMERGENCY MANAGEMENT QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emergency Emergency Management Qualification Standard Reference Guide JUNE 2009 Table of Contents i LIST OF FIGURES ...................................................................................................................... ii LIST OF TABLES ........................................................................................................................ ii ACRONYMS .................................................................................................................................. i PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

260

Uranium Certified Reference Materials Price List  

NLE Websites -- All DOE Office Websites (Extended Search)

Safety & Health spacer Office of Science Chicago Office - New Brunswick Laboratory Uranium Certified Reference Materials Price List Return to Price List Page NOTE: These costs...

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

NIST Standard Reference Database 1A  

Science Conference Proceedings (OSTI)

... These terms may refer to the whole product (NIST 11 ... bar of the Librarian tab to enter the m ... The User spectrum Search and the Structure Search are ...

2012-07-16T23:59:59.000Z

262

Annual Energy Outlook 2011 Reference Case  

U.S. Energy Information Administration (EIA)

Title: Annual Energy Outlook 2011 Reference Case Author: USCX Last modified by: CH4 Created Date: 4/11/2011 8:46:50 PM Document presentation format

263

Portfolio Manager Technical Reference: Canadian National Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

Home Buildings & Plants Portfolio Manager Technical Reference: Canadian National Energy Use Intensity Secondary menu About us Press room Contact Us Portfolio Manager Login...

264

NIST Transfer radiometers and reference detectors  

Science Conference Proceedings (OSTI)

... We are presently developing a pair of next generation reference detectors: an ... development for use as a primary standard in low power calibrations. ...

2013-04-10T23:59:59.000Z

265

Recycling in America: A Reference Handbook  

E-Print Network (OSTI)

and academic libraries, the handbook presents a nontechnicalRecycling in America: A Reference Handbook Patricia Murphy Handbook (Contemporary World Issues

Murphy, Patricia

1994-01-01T23:59:59.000Z

266

Smithells Metals Reference Book (8th Edition)  

Science Conference Proceedings (OSTI)

Feb 12, 2007 ... This comprehensive reference provides data on all key aspects of metallic materials, including narrative information on metallurgical and ...

267

FAQS Reference Guide – Nuclear Safety Specialist  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the November 2007 edition of DOE-STD-1183-2007, Nuclear Safety Specialist Functional Area Qualification Standard.

268

International linear collider reference design report  

E-Print Network (OSTI)

for the Baseline cost estimate, may eventually prove bene?Reference Design and associated cost estimate began. The GDEand reviewing the cost estimate. • A Design and Cost Board (

Aarons, G.

2008-01-01T23:59:59.000Z

269

NIST Photoionization of CO2 References  

Science Conference Proceedings (OSTI)

... A. Dalgarno and JL Fox, Unimolecular and Bimolecular Ion-Molecule ... references on CO 2 research using electron energy loss spectroscopy. ...

2010-10-05T23:59:59.000Z

270

References and Notes for Astatine ( At )  

Science Conference Proceedings (OSTI)

... Switch to Formatted Version References and Notes for Astatine ( At ). M64a R. McLaughlin, J. Opt. Soc. Am. 54, 965 (1964).

271

NETL: Climate Change Policy Support: Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Climate Change Policy Support Reference Shelf NETL-sponsored Symposia at the AAAS Annual Meeting Battery-Powered Electric and Hybrid Electric Vehicle Projects to Reduce Greenhouse...

272

FAQS Reference Guide – Safeguards and Security  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the May 2009 edition of DOE-STD-1171-2009, Safeguards and Security Functional Area Qualification Standard.

273

NISTIR 7617, Mobile Forensic Reference Materials  

Science Conference Proceedings (OSTI)

... The SIM1.xml and SIM2.xml files contain basic reference data cases, while SIM3.xml contains unconventional data cases under consideration and ...

2012-03-01T23:59:59.000Z

274

FAQS Reference Guide – Criticality Safety (NNSA)  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide has been developed to address the competency statements in DOE-STD-1173-2009, Criticality Safety Functional Area Qualification Standard.

275

Category:Hydrogen References | Open Energy Information  

Open Energy Info (EERE)

Hydrogen References Jump to: navigation, search This category currently contains no pages or media. Retrieved from "http:en.openei.orgwindex.php?titleCategory:HydrogenReferen...

276

Property:ReferenceGenre | Open Energy Information  

Open Energy Info (EERE)

genre or subcategory label of reference material. Allows Values Buildings;Geothermal;Hydrogen;Smart Grid;Solar;Utilities;Water;Wind Retrieved from "http:en.openei.orgw...

277

FAQS Reference Guide – Weapon Quality Assurance  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the August 2008 edition of DOE-STD-1025-2008, Weapon Quality Assurance Functional Area Qualification Standard.

278

FAQS Reference Guide – NNSA Package Certification Engineer  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the February 2009 edition of DOE-STD-1026-2009, NNSA Package Certification Engineer Functional Area Qualification Standard.

279

Reference Number PCR Kit Name Manufacturer Kit ...  

Science Conference Proceedings (OSTI)

Page 1. Reference Number PCR Kit Name Manufacturer Kit Description 1 Profiler Life Technologies AmpFlSTR® Profiler® (Part number 403038) ...

2013-11-20T23:59:59.000Z

280

Emergency Responder Radioactive Material Quick Reference Sheet...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

This job aid is a quick reference to assist emergency responders in identifying preliminary safety precautions that should be taken during the initial response phase after arrival...

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Load-shape development aids planning  

SciTech Connect

The concept that provides capable, load-shape development, is being adopted by several utilities and power pools. Public Service Electric and Gas Company has developed a computer simulation model that can predict a utility's load shape for up to a 30-year period. The objective of the PSE and G model, known as EICS (Electric Load-Curve Synthesis) is to provide a demand profile, to examine the impact of load mangement and other activities upon a system's load shape, and to apply appropriate forecast non-load-management and load-management impacts before finally examining the resulting revised load-shape. Other models dealing with load-shape are discussed. Specifically, the Systems Control Inc. model for EPRI (SCI/EPRI), useful in performing accurate simulations of various load-control strategies involving customer appliance control is mentioned.

Gellings, C.W.

1979-12-15T23:59:59.000Z

282

Characterizing Household Plug Loads through Self-Administered Load Research  

Science Conference Proceedings (OSTI)

Household miscellaneous loads, which include consumer electronics, are the fastest growing segment of household energy use in the United States. Although the relative energy intensity of applications such as heating and cooling is declining, the DOEAnnual Energy Outlook forecasts that the intensity of residential miscellaneous end uses will increase substantially by 2030. Studies by TIAX and Ecos Consulting reveal that miscellaneous devices8212smaller devices in terms of energy draw but growing in usage8...

2009-12-09T23:59:59.000Z

283

Archived Reference Building Type: Outpatient health care  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

284

Archived Reference Building Type: Outpatient health care  

Energy.gov (U.S. Department of Energy (DOE))

Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

285

EPRI Live Working Reference Book, Third Edition  

Science Conference Proceedings (OSTI)

This report is a fully revised, updated, and expanded edition of the EPRI Live Working Reference Book, Second Edition (1024479), published by EPRI in 2011. The EPRI Live Working Reference Book, Third Edition provides the utility industry with a single, comprehensive, updated guidebook on live working standards, tools, and procedures. Results and ...

2012-12-31T23:59:59.000Z

286

EPRI Live Working Reference Book, Ed. 4  

Science Conference Proceedings (OSTI)

This report is a fully revised, updated, and expanded edition of the EPRI Live Working Reference Book, Third Edition (1024142), published by EPRI in 2012. The EPRI Live Working Reference Book, Fourth Edition (3002000891) provides the utility industry with a single, comprehensive, updated guidebook on live working standards, tools, and procedures.BackgroundDeregulation demands higher levels of ...

2013-12-27T23:59:59.000Z

287

Flexible reference trace reduction for VM simulations  

Science Conference Proceedings (OSTI)

The unmanageably large size of reference traces has spurred the development of sophisticated trace reduction techniques. In this article we present two new algorithms for trace reduction: Safely Allowed Drop (SAD) and Optimal LRU Reduction ... Keywords: cache hierarchies, locality, reference traces, trace compression, trace reduction

Scott F. Kaplan; Yannis Smaragdakis; Paul R. Wilson

2003-01-01T23:59:59.000Z

288

Property:Reference material | Open Energy Information  

Open Energy Info (EERE)

Reference material Reference material Jump to: navigation, search Property Name Reference material Property Type Page Description The reference material used or cited in the work, activity or concept which is the subject of the page. Pages using the property "Reference material" Showing 25 pages using this property. (previous 25) (next 25) 2 2-M Probe At Alum Area (Kratt, Et Al., 2010) + Boom And Bust With The Latest 2M Temperature Surveys- Dead Horse Wells, Hawthorne Army Depot, Terraced Hills, And Other Areas In Nevada + 2-M Probe At Astor Pass Area (Kratt, Et Al., 2010) + Boom And Bust With The Latest 2M Temperature Surveys- Dead Horse Wells, Hawthorne Army Depot, Terraced Hills, And Other Areas In Nevada + 2-M Probe At Black Warrior Area (DOE GTP) + GTP ARRA Spreadsheet +

289

Category:Reference Materials | Open Energy Information  

Open Energy Info (EERE)

Category Category Edit History Facebook icon Twitter icon » Category:Reference Materials (Redirected from Reference Materials) Jump to: navigation, search This is a deprecated subcategory. All Reference Materials will be converted to References. Pages in category "Reference Materials" The following 200 pages are in this category, out of 2,265 total. (previous 200) (next 200) 1 10 CFR § 1021 2 2-D Magnetotellurics At The Geothermal Site At Soultz-Sous-Forets- Resistivity Distribution To About 3000 M Depth 2.8-Ma Ash-Flow Caldera At Chegem River In The Northern Caucasus Mountains (Russia), Contemporaneous Granites, And Associated Ore Deposits 238U Decay Series Systematics Of Young Lavas From Batur Volcano, Sunda Arc 2D Joint Inversion Of Dc And Scalar Audio-Magnetotelluric Data In The Evaluation Of Low Enthalpy Geothermal Fields

290

Load Scheduling with Profile Information  

E-Print Network (OSTI)

. Within the past five years, many manufactures have added hardware performance counters to their microprocessors to generate profile data cheaply. We show how to use Compaq's DCPI tool to determine load latencies which are at a fine, instruction granularity and use them as fodder for improving instruction scheduling. We validate our heuristic for using DCPI latency data to classify loads as hits and misses against simulation numbers. We map our classification into the Multiflow compiler's intermediate representation, and use a locality sensitive Balanced scheduling algorithm. Our experiments illustrate that our algorithm improves run times by 1% on average, but up to 10% on a Compaq Alpha. 1 Introduction This paper explores how to use hardware performance counters to produce fine grain latency information to improve compiler scheduling. We use this information to hide latencies with any available instruction level parallelism (ILP). (ILP for an instruction is the number of o...

Götz Lindenmaier; Kathryn S. McKinley; Olivier Temam

2000-01-01T23:59:59.000Z

291

Overall U-values and heating/cooling loads: Manufactured homes  

SciTech Connect

This manual specifies a method for calculating the overall thermal transmittance (also referred to as the overall U-value or U{sub o}), heating load, and cooling load of a manufactured (mobile) home. Rules, examples, and data required by the method are also presented. Compliance with the Department of Housing and Urban Development`s (HUD) U{sub o} and load calculation regulations contained in Sections 3280.506, 3280.510 and 3280.511 of the Manufactured Home Construction and Safety Standards must be demonstrated through the application of the method provided herein.

Conner, C.C.; Taylor, Z.T.

1992-02-01T23:59:59.000Z

292

Overall U-values and heating/cooling loads: Manufactured homes  

SciTech Connect

This manual specifies a method for calculating the overall thermal transmittance (also referred to as the overall U-value or U{sub o}), heating load, and cooling load of a manufactured (mobile) home. Rules, examples, and data required by the method are also presented. Compliance with the Department of Housing and Urban Development's (HUD) U{sub o} and load calculation regulations contained in Sections 3280.506, 3280.510 and 3280.511 of the Manufactured Home Construction and Safety Standards must be demonstrated through the application of the method provided herein.

Conner, C.C.; Taylor, Z.T.

1992-02-01T23:59:59.000Z

293

Overall U-values and heating/cooling loads: Manufactured homes  

SciTech Connect

This manual specifies a method for calculating the overall thermal transmittance (also referred to as the overall U-value or U{sub o}), heating load, and cooling load of a manufactured (mobile) home. Rules, examples, and data required by the method are also presented. Compliance with the Department of Housing and Urban Development's (HUD) U{sub o} and load calculation regulations contained in Sections 3280.506, 3280.510 and 3280.511 of the Manufactured Home Construction and Safety Standards must be demonstrated through the application of the method provided herein.

Conner, C.C.; Taylor, Z.T.

1992-02-01T23:59:59.000Z

294

PASSIVE DETECTION OF VEHICLE LOADING  

SciTech Connect

The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

Garrett, A.

2012-01-03T23:59:59.000Z

295

Electrical and Production Load Factors  

E-Print Network (OSTI)

Load factors are an important simplification of electrical energy use data and depend on the ratio of average demand to peak demand. Based on operating hours of a facility they serve as an important benchmarking tool for the industrial sector. The operating hours of small and medium sized manufacturing facilities are analyzed to identify the most common operating hour or shift work patterns. About 75% of manufacturing facilities fall into expected operating hour patterns with operating hours near 40, 80, 120 and 168 hours/week. Two types of load factors, electrical and production are computed for each shift classification within major industry categories in the U.S. The load factor based on monthly billing hours (ELF) increases with operating hours from about 0.4 for a nominal one shift operation, to about 0.7 for around-the-clock operation. On the other hand, the load factor based on production hours (PLF) shows an inverse trend, varying from about 1.4 for one shift operation to 0.7 for around-the-clock operation. When used as a diagnostic tool, if the PLF exceeds unity, then unnecessary energy consumption may be taking place. For plants operating at 40 hours per week, the ELF value was found to greater than the theoretical maximum, while the PLF value was greater than one, suggesting that these facilities may have significant energy usage outside production hours. The data for the PLF however, is more scattered for plants operating less than 80 hours per week, indicating that grouping PLF data based on operating hours may not be a reasonable approach to benchmarking energy use in industries. This analysis uses annual electricity consumption and demand along with operating hour data of manufacturing plants available in the U.S. Department of Energy’s Industrial Assessment Center (IAC) database. The annual values are used because more desirable monthly data are not available. Monthly data are preferred as they capture the load profile of the facility more accurately. The data there come from Industrial Assessment Centers which employ university engineering students, faculty and staff to perform energy assessments for small to medium-sized manufacturing plants. The nation-wide IAC program is sponsored by the U.S. Department of Energy.

Sen, Tapajyoti

2009-12-01T23:59:59.000Z

296

Analytical Modeling of Wood Frame Shear Walls Subjected to Vertical Load  

E-Print Network (OSTI)

A nonlinear automated parameter fitted analytical model that numerically predicts the load-displacement response of wood frame shear walls subjected to static monotonic loading with and without vertical load is presented. This analytical model referred to as Analytical Model of wood frame SHEar walls subjected to Vertical load (AMSHEV) is based on the kinematic behavior of wood frame shear walls and captures significant characteristics observed from experimental testing through appropriate modeling of three failure mechanisms that can occur within a shear wall under static monotonic load: 1) failure of sheathing-to-framing connectors, 2) failure of vertical studs, and 3) uplift of end studs from bottom sill. Previous models have not accounted for these failure mechanisms as well as the inclusion of vertical load, which has shown to reveal beneficial effects such as increasing the ultimate load capacity and limiting uplift of the wall as noted in experimental tests. Results from the proposed numerical model capture these effects within 7% error of experimental test data even when different magnitudes of vertical load are applied to predict the ultimate load capacity of wood frame shear walls.

Nguyendinh, Hai

2011-05-01T23:59:59.000Z

297

Reference Buildings by Climate Zone and Representative City:...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

& Publications Reference Buildings by Climate Zone and Representative City: 2A Houston, Texas Reference Buildings by Building Type: Small Hotel Reference Buildings by Climate Zone...

298

Microsoft Word - Cross Reference Matrix Introduction.doc | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Microsoft Word - Cross Reference Matrix Introduction.doc Microsoft Word - Cross Reference Matrix Introduction.doc Microsoft Word - Cross Reference Matrix Introduction.doc More...

299

Microsoft Word - Cross Reference Matrix Introduction.doc | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cross Reference Matrix Introduction.doc Microsoft Word - Cross Reference Matrix Introduction.doc Microsoft Word - Cross Reference Matrix Introduction.doc More Documents &...

300

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network (OSTI)

of Estimated Load Reductions for PJM’s Small Customer Loadof Estimated Load Reductions for PJM’s Small Customer LoadResponse Pilot Project Prepared for PJM Interconnection, LLC

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Additional solar/load ratio correlations for direct gain buildings  

DOE Green Energy (OSTI)

Solar/load ratio (SLR) correlations have been developed for two new reference direct gain designs. The new reference designs are identical to the originals except that the glazing air gap has been increased from 1/4 in. to 1/2 in. and a vector average of the local hourly windspeed was used in the thermal network calculations rather than an assumed average value of 15 m.p.h. Both of these modifications are realistic and enhance the predicted performance of direct gain buildings. A comprehensive set of mass sensitivity calculations has been performed in order to provide information needed to select an appropriate set of parameters for new lightweight direct gain designs for which additional SLR correlations will be developed. Representative results are reported.

Wray, W.O.

1980-01-01T23:59:59.000Z

302

Category:References | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Category Edit History Facebook icon Twitter icon » Category:References Jump to: navigation, search Add a new Reference. Subcategories This category has the following 9 subcategories, out of 9 total. B [×] Buildings References‎ G [×] Geothermal References‎ 290 pages H [×] Hydrogen References‎ R [×] Reference Materials‎ 2265 pages S [×] Smart Grid References‎ [×] Solar References‎ 1 pages U [×] Utilities References‎ W [×] Water References‎ 2 pages [×] Wind References‎ 1 pages Pages in category "References" The following 200 pages are in this category, out of 295 total. (previous 200) (next 200)

303

AVIATION SAFETY OFFICER QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Safety Safety Officer Qualification Standard Reference Guide MARCH 2010 i This page is intentionally blank. Table of Contents ii LIST OF FIGURES ..................................................................................................................... iii LIST OF TABLES ....................................................................................................................... iii ACRONYMS ............................................................................................................................... iv PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

304

NETL: Methane Hydrates - Methane Hydrate Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Shelf Reference Shelf The Methane Hydrate Reference Shelf was created to provide a repository for information collected from projects funded as part of the National Methane Hydrate R&D Program. As output from the projects is received, it will be reviewed and then placed onto the reference shelf to be available to other methane hydrate researchers. Projects: DOE/NETL Projects : These pages contain detailed information on methane hydrate projects funded through the National Energy Technology Laboratory. Publications: Newsletter | Bibliography | Software | Reports | Program Publications | Photo Gallery Newsletter: Fire in the Ice: A publication highlighting the National Methane Hydrate R&D Program Bibliography: "Project Reports Bibliography"[PDF]: The bibliography lists publications resulting from DOE/NETL-sponsored

305

TECHNICAL TRAINING QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technical Technical Training Qualification Standard Reference Guide December 2009 This page is intentionally blank. Table of Contents i LIST OF FIGURES ...................................................................................................................... ii LIST OF TABLES ........................................................................................................................ ii ACRONYMS ................................................................................................................................ iii PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

306

WEAPONS QUALITY ASSURANCE QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Weapon Weapon Quality Assurance Qualification Standard Reference Guide AUGUST 2009 This page is intentionally blank. Table of Contents i LIST OF FIGURES ...................................................................................................................... ii LIST OF TABLES ........................................................................................................................ ii ACRONYMS ................................................................................................................................ iv PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

307

SAFEGUARDS AND SECURITY QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and Security Qualification Standard Reference Guide OCTOBER 2010 This page is intentionally blank. Table of Contents i LIST OF TABLES ........................................................................................................................ v ACRONYMS ................................................................................................................................ vi PURPOSE ...................................................................................................................................... 1 SCOPE ........................................................................................................................................... 1 PREFACE ...................................................................................................................................... 1

308

GENERAL TECHNICAL BASE QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

General General Technical Base Qualification Standard Reference Guide MARCH 2012 This page is intentionally blank. Table of Contents i FIGURES ...................................................................................................................................... iii TABLES ........................................................................................................................................ iii ACRONYMS ................................................................................................................................ iv PURPOSE ...................................................................................................................................... 1 SCOPE ........................................................................................................................................... 1

309

NUCLEAR SAFETY SPECIALIST QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nuclear Nuclear Safety Specialist Qualification Standard Reference Guide AUGUST 2008 This page is intentionally blank. i Table of Contents LIST OF FIGURES ..................................................................................................................... iv LIST OF TABLES ........................................................................................................................ v ACRONYMS ................................................................................................................................ vi PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

310

Fire Protection Engineering Qualification Standard Reference Guide  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fire Protection Fire Protection Engineering Qualification Standard Reference Guide SEPTEMBER 2009 This page is intentionally blank. Table of Contents i ACRONYMS ................................................................................................................................. ii PURPOSE.......................................................................................................................................1 SCOPE ............................................................................................................................................1 PREFACE.......................................................................................................................................1 TECHNICAL COMPETENCIES................................................................................................3

311

WASTE MANAGEMENT QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Qualification Standard Qualification Standard Reference Guide August 2010 Waste Management This page is intentionally blank. Table of Contents iii LIST OF FIGURES ..................................................................................................................... iv LIST OF TABLES ........................................................................................................................ v ACRONYMS ................................................................................................................................ vi PURPOSE ...................................................................................................................................... 1 SCOPE ........................................................................................................................................... 1

312

OCCUPATIONAL SAFETY QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Qualification Standard Qualification Standard Reference Guide JULY 2011 Occupational Safety This page is intentionally blank. Table of Contents i FIGURES ...................................................................................................................................... iii TABLES ........................................................................................................................................ iv ACRONYMS ................................................................................................................................. v PURPOSE ...................................................................................................................................... 1 SCOPE ........................................................................................................................................... 1

313

NEWTON's Environmental and Earth Science References  

NLE Websites -- All DOE Office Websites (Extended Search)

Environmental and Earth Science References Environmental and Earth Science References Do you have a great reference link? Please click our Ideas page. Featured Reference Links: >NASA's Earth Science Division NASA's Earth Science Division Find the answers to the big questions of Earth Science such as "How is the World Changing?" The information and articles are provided by NASA's Earth Science Division Geology.com Resources Teaching Earth Science - Geology.com Geology.com provides news and information about Geology and Earth Science. It has a teacher resource section as well, which provides a collection of classroom activities and lesson plans, for earth science in the classroom. IRIS's Seismographs in Schools Program IRIS's Seismographs in Schools Program Discover tools to share seismic data in real-time, classroom activities, and technical support documents for seismic instruments.

314

INDUSTRIAL HYGIENE QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Industrial Industrial Hygiene Qualification Standard Reference Guide DECEMBER 2009 This page is intentionally blank. Table of Contents i LIST OF FIGURES ...................................................................................................................... ii LIST OF TABLES ........................................................................................................................ ii ACRONYMS ................................................................................................................................ iv PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

315

Category:Reference Materials | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Category Edit History Facebook icon Twitter icon » Category:Reference Materials Jump to: navigation, search This is a deprecated subcategory. All Reference Materials will be converted to References. Pages in category "Reference Materials" The following 200 pages are in this category, out of 2,265 total. (previous 200) (next 200) 1 10 CFR § 1021 2 2-D Magnetotellurics At The Geothermal Site At Soultz-Sous-Forets- Resistivity Distribution To About 3000 M Depth 2.8-Ma Ash-Flow Caldera At Chegem River In The Northern Caucasus Mountains (Russia), Contemporaneous Granites, And Associated Ore Deposits 238U Decay Series Systematics Of Young Lavas From Batur Volcano, Sunda Arc

316

CONSTRUCTION MANAGEMENT QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Construction Construction Management Qualification Standard Reference Guide August 2009 This page is intentionally blank. Table of Contents i LIST OF FIGURES ..................................................................................................................... iv LIST OF TABLES ........................................................................................................................ v ACRONYMS ................................................................................................................................ vi PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

317

RADIATION PROTECTION QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiation Radiation Protection Qualification Standard Reference Guide MARCH 2009 ii This page intentionally left blank iii Table of Contents LIST OF FIGURES ..................................................................................................................... iv LIST OF TABLES ....................................................................................................................... iv ACRONYMS, ABBREVIATIONS and SYMBOLS ................................................................. v PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

318

An expectation model of referring expressions  

E-Print Network (OSTI)

This thesis introduces EMRE, an expectation-based model of referring expressions. EMRE is proposed as a model of non-syntactic dependencies - in particular, discourse-level semantic dependencies that bridge sentence gaps. ...

Kræmer, John, Ph. D. Massachusetts Institute of Technology

2010-01-01T23:59:59.000Z

319

Building Technologies Office: Existing Commercial Reference Buildings...  

NLE Websites -- All DOE Office Websites (Extended Search)

You can also view related resources: an archive of past reference buildings files a ZIP file containing the TMY2 weather data that were used to generate the following...

320

DISCLAIMER Commercial equipment and software referred to ...  

Science Conference Proceedings (OSTI)

... 118? • Field 2, 2.5 nm cells, 8-dot exchange: 71.9? • Field 2, 3.125 nm cells, 4-ang exchange: 48.1? Exchange reference: ...

2008-01-15T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Computational generation of referring expressions: A survey  

Science Conference Proceedings (OSTI)

This article offers a survey of computational research on referring expression generation (REG). It introduces the REG problem and describes early work in this area, discussing what basic assumptions lie behind it, and showing how its remit has widened ...

Emiel Krahmer; Kees van Deemter

2012-03-01T23:59:59.000Z

322

Javarifier : inference of reference immutability in Java  

E-Print Network (OSTI)

Javari is an extension of Java that supports reference immutability constraints. Programmers write Javari type qualifiers, such as the readonly type qualifier, in their programs, and the Javari typechecker detects mutation ...

Quinonez, Jamie

2008-01-01T23:59:59.000Z

323

Excepted Service EJ and EK Desk Reference  

Energy.gov (U.S. Department of Energy (DOE))

The Excepted Service EJ and EK Desk Reference is designed to provide the framework, in conjunction, with the DOE O 329.1 (Excepted Service Authorities for EJ and EK Pay Plans). Specifically, the...

324

Direct versus Facility Centric Load Control for Automated Demand Response  

SciTech Connect

Direct load control (DLC) refers to the scenario where third party entities outside the home or facility are responsible for deciding how and when specific customer loads will be controlled in response to Demand Response (DR) events on the electric grid. Examples of third parties responsible for performing DLC may be Utilities, Independent System Operators (ISO), Aggregators, or third party control companies. DLC can be contrasted with facility centric load control (FCLC) where the decisions for how loads are controlled are made entirely within the facility or enterprise control systems. In FCLC the facility owner has more freedom of choice in how to respond to DR events on the grid. Both approaches are in use today in automation of DR and both will continue to be used in future market segments including industrial, commercial and residential facilities. This paper will present a framework which can be used to differentiate between DLC and FCLC based upon where decisions are made on how specific loads are controlled in response to DR events. This differentiation is then used to compare and contrast the differences between DLC and FCLC to identify the impact each has on:(1)Utility/ISO and third party systems for managing demand response, (2)Facility systems for implementing load control, (3)Communications networks for interacting with the facility and (4)Facility operators and managers. Finally a survey of some of the existing DR related specifications and communications standards is given and their applicability to DLC or FCLC. In general FCLC adds more cost and responsibilities to the facilities whereas DLC represents higher costs and complexity for the Utility/ISO. This difference is primarily due to where the DR Logic is implemented and the consequences that creates. DLC may be more certain than FCLC because it is more predictable - however as more loads have the capability to respond to DR signals, people may prefer to have their own control of end-use loads and FCLC systems. Research is needed to understand the predictability of FCLC which is related to the perceived value of the DR from the facility manager or home owner's perspective.

Koch, Ed; Piette, Mary Ann

2009-11-06T23:59:59.000Z

325

Automated fuel pin loading system  

DOE Patents (OSTI)

An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inserted as a batch prior to welding of end caps by one of two disclosed welding systems.

Christiansen, David W. (Kennewick, WA); Brown, William F. (West Richland, WA); Steffen, Jim M. (Richland, WA)

1985-01-01T23:59:59.000Z

326

High loading uranium fuel plate  

DOE Patents (OSTI)

Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

Wiencek, Thomas C. (Bolingbrook, IL); Domagala, Robert F. (Indian Head Park, IL); Thresh, Henry R. (Palos Heights, IL)

1990-01-01T23:59:59.000Z

327

Interruptible load control for Taiwan Power Company  

SciTech Connect

Load management is the planning and implementation of those utility activities designed to influence customer use of electricity in ways that will produce desired changes in the utility's load shape. Interruptible load program is an option of load management which provides incentive rate to customers to interrupt or reduce the power demand during the system peak period or emergency condition. Therefore, how to design a proper incentive rate is the most important issue in implementing this program. This paper describes three alternatives designed for the interruptible load program, one of which was activated by Taiwan Power Company (Taipower) and some preliminary results were obtained. The effect of the interruptible load to the system peak demand reduction and the change of daily load curve for large industrial customers were analyzed. This paper estimates the avoided cost and design more appropriate incentive rate structure for interruptible load program.

Chen, C.S.; Leu, J.T. (Dept. of Electrical Engineering, National Sun Yat-Sen Univ., Kaohsiung (TW))

1990-05-01T23:59:59.000Z

328

Loads on drillpipe during jarring operations  

Science Conference Proceedings (OSTI)

Jarring implies heavy loads on the drillstring. The highest load on the drillpipe before jarring is at the rig floor. This paper discusses loads on drillpipe before, under, and after jarring. The authors show that for most situations, the shock wave from the jar impact does not imply additional load on the drillpipe compared with static load. The theoretical results are confirmed by measurements of a jarring operation with stuck point at [approx] 1,200 m measured depth. Loads on the drillpipe can be a limited factor in jarring operations because fear of possible additional loads from jarring dynamics may restrict the trip force (overpull) on the jar. The main conclusion is that dynamic jar forces do not give additional loads on drillpipe. This information can be used to set an optimal trip force on the jar.

Aarrestad, T.V.; Kyllingstad, A.

1994-12-01T23:59:59.000Z

329

1994 Pacific Northwest Loads and Resources Study.  

Science Conference Proceedings (OSTI)

The 1994 Pacific Northwest Loads and Resources Study presented herein establishes a picture of how the agency is positioned today in its loads and resources balance. It is a snapshot of expected resource operation, contractual obligations, and rights. This study does not attempt to present or analyze future conservation or generation resource scenarios. What it does provide are base case assumptions from which scenarios encompassing a wide range of uncertainties about BPA`s future may be evaluated. The Loads and Resources Study is presented in two documents: (1) this summary of Federal system and Pacific Northwest region loads and resources and (2) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. This analysis updates the 1993 Pacific Northwest Loads and Resources Study, published in December 1993. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The Federal system and regional analyses for medium load forecast are presented.

United States. Bonneville Power Administration.

1994-12-01T23:59:59.000Z

330

First Edition Underground Distribution Reference Book  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) is developing a first edition of the Underground Distribution Systems Reference (Bronze Book). This report will join the EPRI series of transmission and distribution technical reference reports, commonly known by the color of their covers. The report will be a desk and field compendium on the general principles involved in the planning, design, manufacture, installation design, installation, testing, operation, and maintenance of underground distribution syste...

2009-12-22T23:59:59.000Z

331

Regional load curve models: specification and estimation of the DRI Model. Final report. [Forecasts of electric loads in 32 US regions  

SciTech Connect

The DRI Model of hourly load curves is developed in this report. The model is capable of producing long-term forecasts for 32 US regions. These regions were created by aggregating hourly system load data from 146 electric utilities. These utilities supply approximately 95% of all electricity consumed in the continental US. The model forecasts electricity demands for each hour of the year for each of the 32 regions. Model output includes forecasts of peak demands, megawatt hour demands, load factors, and load duration curves. The DRI Model is estimated in two stages. In the first stage, for each region and month, hourly electricity demands are parameterized into load components representing the effects of lifestyles and weather on regional loads through a time-series model. In the second stage, the variation in these parameterized load components across months and regions is modeled econometrically in terms of energy prices, income levels, appliance saturation rates, and other variables. The second-stage models are essentially models of electricity demand which are estimated using estimated first-stage parameters as dependent variables, instead of observed demands. Regional price and income demand elasticities are implied by the second-stage models. Moreover, since the dependent variables refer to particular hours of the day, these estimated elasticities are hour-specific. (Since prices did not vary over the day in years when hourly load data were available, hour-to-hour, cross-price elasticities were not estimated.) Integrated system hourly load forecasts are obtained combining the influences of individual customer classes. Finally, approximate customer class hourly load shapes can be produced for each region, though these series may be useful only in research endeavors since they lack the precision available through survey methods.

Platt, H.D.; Einhorn, M.A.; Ignelzi, P.C.; Poirier, D.J.

1981-01-01T23:59:59.000Z

332

Plug Load Behavioral Change Demonstration Project  

SciTech Connect

This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

Metzger, I.; Kandt, A.; VanGeet, O.

2011-08-01T23:59:59.000Z

333

Spinning reserve from hotel load response  

SciTech Connect

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid. (author)

Kirby, Brendan; Kueck, John; Laughner, Theo; Morris, Keith

2008-12-15T23:59:59.000Z

334

Load Shape Library Version 1.0  

Science Conference Proceedings (OSTI)

The downloadable report details EPRI's efforts to develop a framework of a load database and web-accessible repository of end-use and whole-premise data for application to energy efficiency assessments. The tool provides access to the best available end-use load data and whole-premise data by sector, region and building type. Improved end-use load research data will benefit load forecasters, system planners, energy efficiency program managers and rate design analysts by facilitating integration ...

2013-02-12T23:59:59.000Z

335

Computer Forensic Reference Data Sets (CFReDS)  

Science Conference Proceedings (OSTI)

Computer Forensic Reference Data Sets. Summary: ... NIST is developing Computer Forensic Reference Data Sets (CFReDS) for digital evidence. ...

2010-10-05T23:59:59.000Z

336

Glossary of terms related to load management  

Science Conference Proceedings (OSTI)

Part I of the Glossary of Terms related to Load Management has been prepared by the Terminology Task Force of the Load Management Subcommittee. The glossary contains many definitions of terms used by the electric utility industry concerning the subject of Load Management. The terms are listed in alphabetical order and cross-referenced where necessary.

Gellings, C.W.

1985-09-01T23:59:59.000Z

337

Properly Evaluating load-following products  

SciTech Connect

The authors briefly survey the jurisdictions where load-following products have been successfully used, examine the characteristics of the load-following products, and explain the shortcomings and inaccurate conclusions of previous analyses. A more thorough analysis reveals that the load-following products fulfill the public policy objectives for which they have been designed and do not adversely impact wholesale electricity markets.

Cavicchi, Joseph; Lemon, Andrew

2009-01-15T23:59:59.000Z

338

Adaptive load sharing for network processors  

Science Conference Proceedings (OSTI)

A novel scheme for processing packets in a router is presented that provides load sharing among multiple network processors distributed within the router. It is complemented by a feedback control mechanism designed to prevent processor overload. Incoming ... Keywords: computer networks, feedback control, load balancing, load sharing, packet processing, router architecture

Lukas Kencl; Jean-Yves Le Boudec

2008-04-01T23:59:59.000Z

339

Efficient real-time divisible load scheduling  

Science Conference Proceedings (OSTI)

Providing QoS and performance guarantees to arbitrarily divisible loads has become a significant problem for many cluster-based research computing facilities. While progress is being made in scheduling arbitrarily divisible loads, current approaches ... Keywords: Arbitrarily divisible loads, Cluster computing, Real-time computing, Scheduling efficiency

Anwar Mamat; Ying Lu; Jitender Deogun; Steve Goddard

2012-12-01T23:59:59.000Z

340

Domestic load scheduling using genetic algorithms  

Science Conference Proceedings (OSTI)

An approach using a genetic algorithm to optimize the scheduling of domestic electric loads, according to technical and user-defined constraints and input signals, is presented and illustrative results are shown. The aim is minimizing the end-user's ... Keywords: automated energy management, domestic load scheduling, electric loads, genetic algorithms

Ana Soares; Állvaro Gomes; Carlos Henggeler Antunes; Hugo Cardoso

2013-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Neural-wavelet Methodology for Load Forecasting  

Science Conference Proceedings (OSTI)

Intelligent demand-side management represents a future trend of power system regulation. A key issue in intelligent demand-side management is accurate prediction of load within a local area grid (LAG), which is defined as a set of customers with an appropriate ... Keywords: load forecasting, load identification, neural-wavelet

Rong Gao; Lefteri H. Tsoukalas

2001-05-01T23:59:59.000Z

342

Load Management - A Better Way  

E-Print Network (OSTI)

Ohio Edison Company serves about 800,000 customers in Ohio and Pennsylvania, making it one of the 20 largest electric utilities in the nation. The 'cost of service' concept has been basic to rate design throughout the history of the company, and is evident today as the demand related charges have escalated in recent rate cases reflecting the higher costs of installing new generating facilities at today's high construction and financing costs. This paper will describe one of the many applications of load management techniques which has enabled the company to shift well over 100,000 kilowatts of customer load from the on-peak period to the off-peak period in the last four to five years. This is helping delay the need for new plants and allows existing plants to be more fully utilized, resulting in lower costs to customers who use their electric service wisely and possibly lower rate increases in the future than would have been required otherwise.

Easley, J. F.

1982-01-01T23:59:59.000Z

343

Load Scheduling with Profile Information  

E-Print Network (OSTI)

Abstract Within the past five years, many manufactureshave added hardware performance counters to their microprocessors to generate profile data cheaply.Translating aggregate data such as basic block execution frequencies from the executable to the com-piler intermediate representation is fairly straightforward. In this paper, we show how to use Com-paq's DCPI tool to determine load latencies which are at a fine, instruction granularity and then usethem to provide fodder for improving instruction scheduling. We validate our heuristic for usingDCPI latency data to classify loads as hits and misses against simulation numbers, demonstratingthat we can gather correct latencies cheaply at runtime. We map our classification into the Multiflowcompiler's intermediate representation, and use a locality sensitive Balanced scheduling algorithm. Ourexperiments illustrate that our algorithm has the potential to improve run times by up to 10 % on a Com-paq Alpha when compared to Balanced scheduling, but that a variety of pitfalls make consistent im-provements difficult to attain. 1 Introduction In this paper, we explore how to use hardware per-formance counters to produce fine grain latency information to improve compiler scheduling. We usethis information to hide latencies with any avail\\Lambda The authors

unknown authors

1999-01-01T23:59:59.000Z

344

1993 Pacific Northwest Loads and Resources Study.  

SciTech Connect

The Loads and Resources Study is presented in three documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The forecasted future electricity demands -- firm loads -- are subtracted from the projected capability of existing and {open_quotes}contracted for{close_quotes} resources to determine whether Bonneville Power Administration (BPA) and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, and additional conservation, contract purchases, or generating resources will be needed to meet load growth. The Pacific Northwest Loads and Resources Study analyzes the Pacific Northwest`s projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional power system, which includes loads and resource in addition to the Federal system. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA) produced by the Pacific Northwest Coordinating Group. This study presents the Federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 1994--95 through 2003--04.

United States. Bonneville Power Administration.

1993-12-01T23:59:59.000Z

345

6.8. Searchable Index of Reference Pages  

Science Conference Proceedings (OSTI)

... OOF.File.Load.OrientationMap. Menu Item. OOF.File.Load.Script. Menu Item. ... OOF.Help.Debug.Debug. Menu Item. OOF.Help.Debug.Profile. Menu. ...

2013-07-05T23:59:59.000Z

346

High payload six-axis load sensor  

DOE Patents (OSTI)

A repairable high-payload six-axis load sensor includes a table, a base, and at least three shear-pin load transducers removably mounted between the table and the base. Removable mounting permits easy replacement of damaged shear pins. Preferably, the shear-pin load transducers are responsive to shear forces imparted along the two axes perpendicular to an axis of minimum sensitivity characteristic of the transducer. Responsive to an applied shear force, each shear-pin load transducer can produce an electrical signal proportional to the reaction force. The load sensor can further include a structure for receiving the proportional electrical signals and computing the applied load corresponding to the proportional electrical signals. The computed load can be expressed in terms of a three-dimensional XYZ Cartesian coordinate system.

Jansen, John F. (Knoxville, TN); Lind, Randall F. (Knoxville, TN)

2003-01-01T23:59:59.000Z

347

Analysis Methodology for Industrial Load Profiles  

E-Print Network (OSTI)

A methodology is provided for evaluating the impact of various demand-side management (DSM) options on industrial customers. The basic approach uses customer metered load profile data as a basis for the customer load shape. DSM technologies are represented as load shapes and are used as a basis for altering the customers existing measured load shape. The impact of load shape changes on the customer is evaluated in terms of a change in the electric bill by using a software analytical tool called LOADEXPERT™. The software calculates the customer's bill for a particular rate structure and a given load shape. The output data from LOADEXPERT™ are used to calculate the rate of return on the DSM technology investment. Other uses of load profile data are provided.

Reddoch, T. W.

1991-06-01T23:59:59.000Z

348

Low cutter load raise head  

SciTech Connect

A raise head having a multiplicity of cutters for enlarging a pilot hole into a larger diameter hole by disintegrating the earth formations that surround the pilot hole is provided that will require lower cutter loads to penetrate the formations being bored by directing the rock fracture planes toward the pilot hole forcing the rock to yield with less input energy. The cutters are positioned on the raise head to provide an earth formation contact profile with a major portion of said earth formation contact profile extending outward and upward from said pilot hole. The included angle between the major portion of the earth formation contact profile and the axis of the pilot hole is less than 90/sup 0/.

Saxman, W.C.

1981-03-31T23:59:59.000Z

349

Kinesin's backsteps under mechanical load  

E-Print Network (OSTI)

Kinesins move processively toward the plus end of microtubules by hydrolyzing ATP for each step. From an enzymatic perspective, the mechanism of mechanical motion coupled to the nucleotide chemistry is often well explained using a single-loop cyclic reaction. However, several difficulties arise in interpreting kinesin's backstepping within this framework, especially when external forces oppose the motion of kinesin. We review evidence, such as an ATP-independent stall force and a slower cycle time for backsteps, that has emerged to challenge the idea that kinesin backstepping is due to ATP synthesis, i.e., the reverse cycle of kinesin's forward-stepping chemomechanics. Supplementing the conventional single-loop chemomechanics with routes for ATP-hydrolyzing backward steps and nucleotide-free steps, especially under load, gives a better physical interpretation of the experimental data on backsteps.

Changbong Hyeon; Stefan Klumpp; José N. Onuchic

2009-04-18T23:59:59.000Z

350

FY 93 thermal loading systems study final report: Volume 2. Revision 1  

Science Conference Proceedings (OSTI)

The ability to meet the overall performance requirements for the proposed Mined Geology Disposal System at Yucca Mountain, Nevada requires the two major subsystem (natural barriers and engineered barriers) to positively contribute to containment and radionuclide isolation. In addition to the postclosure performance the proposed repository must meet preclosure requirements of safety, retrievability, and operability. Cost and schedule were also considered. The thermal loading strategy chosen may significantly affect both the postclosure and preclosure performance of the proposed repository. Although the current Site Characterization Plan reference case is 57 kilowatts (kW)/acre, other thermal loading strategies (different areal mass loadings) have been proposed which possess both advantages and disadvantages. The objectives of the FY 1993 Thermal Loading Study were to (1) place bounds on the thermal loading which would establish the loading regime that is ``too hot`` and the loading regime that is ``too cold``, to (2) ``grade`` or evaluate the performance, as a function of thermal loading, of the repository to contain high level wastes against performance criteria and to (3) evaluate the performance of the various options with respect to cost, safety, and operability. Additionally, the effort was to (4) identify important uncertainties that need to be resolved by tests and/or analyses in order to complete a performance assessment on the effects of thermal loading. The FY 1993 Thermal Loading Study was conducted from December 1, 1992 to December 30, 1993 and this final report provides the findings of the study. Volume 2 consists of 10 appendices which contain the following: Waste Stream Analysis; Waste Package Design Inputs; Subsurface Design Inputs; Thermal-Hydrologic Model Inputs; Near-Field Calculations; Far-Field; Reliability of Electronics as a Function of Temperature; Cost Analysis Details; Geochemistry; and Areas of Uncertainty in Thermal Loading.

NONE

1994-08-29T23:59:59.000Z

351

Reference Design? | OpenEI Community  

Open Energy Info (EERE)

Reference Design? Reference Design? Home > Groups > Databus Are there any published reference designs for a DataBus installation? And/or some sort of discussion forum for this- I'd be interested to share thoughts and experiences about the various tradeoffs and options. (I'm not sure this Q&A thing is the best place for that; maybe some other feature of OpenEI?) Submitted by Hopcroft on 9 September, 2013 - 09:04 4 answers Points: 0 darn, the formatting on this forum software is really not that good. Maybe we should consider moving to serverfault.com which has great formatting, emails work, etc. etc. Deanhiller on 9 September, 2013 - 12:20 Points: 0 ah yes, I see your point there!!!! TIME_SERIES vs. RELATIONAL: TIME_SERIES is much much faster for downloads to charting after our performance fixes.

352

Excepted Service EJ and EK Desk Reference  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1] 1] U.S. DEPARTMENT OF ENERGY Office of the Chief Human Capital Officer 2012 Excepted Service EJ and EK Desk Reference E X E C U T I V E R E S O U R C E S D I V I S I O N [2] Executive Summary The Excepted Service EJ and EK Desk Reference is designed to provide the framework, in conjunction, with the DOE O 329.1 (Excepted Service Authorities for EJ and EK Pay Plans). Specifically, the desk reference addresses the requirements for the Excepted Service EJ and EK positions, to include: * Description of the EJ and EK authorities; * Policy of utilizing merit system principles and the Department's commitment to diversity; * The use of collective bargaining agreements applying to some EJ and EK positions; * The types of positions that the EJ and EK authorities apply and prohibited types of

353

Reference Design? | OpenEI Community  

Open Energy Info (EERE)

Reference Design? Reference Design? Home > Groups > Databus Are there any published reference designs for a DataBus installation? And/or some sort of discussion forum for this- I'd be interested to share thoughts and experiences about the various tradeoffs and options. (I'm not sure this Q&A thing is the best place for that; maybe some other feature of OpenEI?) Submitted by Hopcroft on 9 September, 2013 - 09:04 4 answers Points: 0 darn, the formatting on this forum software is really not that good. Maybe we should consider moving to serverfault.com which has great formatting, emails work, etc. etc. Deanhiller on 9 September, 2013 - 12:20 Points: 0 ah yes, I see your point there!!!! TIME_SERIES vs. RELATIONAL: TIME_SERIES is much much faster for downloads to charting after our performance fixes.

354

Category:Geothermal References | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Category Edit History Facebook icon Twitter icon » Category:Geothermal References Jump to: navigation, search Add a new Reference Pages in category "Geothermal References" The following 200 pages are in this category, out of 323 total. (previous 200) (next 200) 2 2-D Magnetotellurics At The Geothermal Site At Soultz-Sous-Forets- Resistivity Distribution To About 3000 M Depth 2007 Annual Report A A Case History of Injection Through 1991 at Dixie Valley, Nevada A Coordinated Exploration Program for Geothermal Sources on the Island of Hawaii A geochemical model of the Kilauea east rift zone A model for the shallow thermal regime at Dixie Valley geothermal field

355

Reference Design? | OpenEI Community  

Open Energy Info (EERE)

Reference Design? Reference Design? Home > Groups > Databus Are there any published reference designs for a DataBus installation? And/or some sort of discussion forum for this- I'd be interested to share thoughts and experiences about the various tradeoffs and options. (I'm not sure this Q&A thing is the best place for that; maybe some other feature of OpenEI?) Submitted by Hopcroft on 9 September, 2013 - 09:04 4 answers Points: 0 darn, the formatting on this forum software is really not that good. Maybe we should consider moving to serverfault.com which has great formatting, emails work, etc. etc. Deanhiller on 9 September, 2013 - 12:20 Points: 0 ah yes, I see your point there!!!! TIME_SERIES vs. RELATIONAL: TIME_SERIES is much much faster for downloads to charting after our performance fixes.

356

Reference Design? | OpenEI Community  

Open Energy Info (EERE)

Reference Design? Reference Design? Home > Groups > Databus Are there any published reference designs for a DataBus installation? And/or some sort of discussion forum for this- I'd be interested to share thoughts and experiences about the various tradeoffs and options. (I'm not sure this Q&A thing is the best place for that; maybe some other feature of OpenEI?) Submitted by Hopcroft on 9 September, 2013 - 09:04 4 answers Points: 0 darn, the formatting on this forum software is really not that good. Maybe we should consider moving to serverfault.com which has great formatting, emails work, etc. etc. Deanhiller on 9 September, 2013 - 12:20 Points: 0 ah yes, I see your point there!!!! TIME_SERIES vs. RELATIONAL: TIME_SERIES is much much faster for downloads to charting after our performance fixes.

357

NETL: Innovations for Existing Plants - Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Shelf Reference Shelf Innovations for Existing Plants Reference Shelf Program Overview Overview Publications: IEP, Recent Accomplishments Report - [PDF-1.3MB] (Oct 2007) IEP Roadmap & Program Plan [PDF-1.2MB] (May 2006) DOE/NETL'S Innovations for Existing Plants R&D Program [PDF-42KB] (Feb 2005) Improving the Environmental Performance of Today's Coal-Fired Power Plants This paper provides an overview of the Innovations for Existing Plants (IEP) Program, managed by the DOE National Energy Technology Laboratory. IEP develops advanced low-cost environmental control technologies for the existing fleet of coal-fired power plants, specifically focusing on the development of advanced mercury, NOx, PM, and acid gas emission control technology. Research is also directed at the characterization and beneficial use of coal utilization byproducts as well as at emerging electric-utility and water issues.

358

Reference Design? | OpenEI Community  

Open Energy Info (EERE)

Reference Design? Reference Design? Home > Groups > Databus Are there any published reference designs for a DataBus installation? And/or some sort of discussion forum for this- I'd be interested to share thoughts and experiences about the various tradeoffs and options. (I'm not sure this Q&A thing is the best place for that; maybe some other feature of OpenEI?) Submitted by Hopcroft on 9 September, 2013 - 09:04 4 answers Points: 0 darn, the formatting on this forum software is really not that good. Maybe we should consider moving to serverfault.com which has great formatting, emails work, etc. etc. Deanhiller on 9 September, 2013 - 12:20 Points: 0 ah yes, I see your point there!!!! TIME_SERIES vs. RELATIONAL: TIME_SERIES is much much faster for downloads to charting after our performance fixes.

359

EIA - Appendix A - Reference Case Projection Tables  

Gasoline and Diesel Fuel Update (EIA)

Tables (2005-2035) Tables (2005-2035) International Energy Outlook 2010 Reference Case Projections Tables (2005-2035) Formats Data Table Titles (1 to 14 complete) Reference Case Projections Tables (1990-2030). Need help, contact the National Energy Information Center at 202-586-8800. Appendix A. Reference Case Projections Tables. Need help, contact the National Energy Information Center at 202-586-8800. Table A1 World Total Primary Energy Consumption by Region Table A1. World Total Primary Energy Consumption by Region. Need help, contact the National Energy Information Center at 202-586-8800. Table A2 World Total Energy Consumption by Region and Fuel Table A2. World Total Energy Consumption by Region and Fuel. Need help, contact the National Energy Information Center at 202-586-8800.

360

DOE_EVMS_CROSS_REFERENCE_CHECKLIST.pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EVMS CROSS REFERENCE CHECKLIST EVMS CROSS REFERENCE CHECKLIST The purpose of this checklist is to evaluate a contractor's EVMS procedures to the ANSI/EIA-748 Guidelines. This process is typically done during a certification review, evaluation of changes to procedures, and when questions arise during subsequent surveillances. This checklist is just one tool. Other references may assist in the evaluation process. A recommended guide to be used in conjunction with this checklist is the NDIA PMSC, Earned Value Management Systems Intent Guide, 2006, http://www.ndia.org/Divisions/Divisions/Procurement/Pages/Program_Management_Systems_Committee.aspx GUIDELINE and QUESTIONS Y/N SD Ref ASSESSMENT NOTES DOCUMENTS I. ORGANIZATION 1. Define the authorized work elements for program. A work breakdown structure (WBS), tailored for effective internal management

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Property:References | Open Energy Information  

Open Energy Info (EERE)

References References Jump to: navigation, search This is a property of type Text. Subproperties This property has the following 43 subproperties: A Active Seismic Techniques Aeromagnetic Survey Airborne Gravity Survey Audio-Magnetotellurics C Chemical Logging Compound and Elemental Analysis Controlled Source Audio MT Controlled Source Frequency-Domain Magnetics D DC Resistivity Survey (Dipole-Dipole Array) DC Resistivity Survey (Mise-Á-La-Masse) DC Resistivity Survey (Pole-Dipole Array) DC Resistivity Survey (Schlumberger Array) DC Resistivity Survey (Wenner Array) Direct-Current Resistivity Survey D cont. Downhole Techniques E Electrical Profiling Configurations Electrical Techniques Electromagnetic Techniques F Frequency-Domain Electromagnetic Survey G Geodetic Survey Geophysical Techniques

362

Investigation of residential central air conditioning load shapes in NEMS  

E-Print Network (OSTI)

of Residential Central Air Conditioning Load Shapes in NEMSof Residential Central Air Conditioning Load Shapes in NEMSof Residential Central Air Conditioning Load Shapes in NEMS

Hamachi LaCommare, Kristina; Marnay, Chris; Gumerman, Etan; Chan, Peter; Rosenquist, Greg; Osborn, Julie

2002-01-01T23:59:59.000Z

363

U-063: RSA SecurID Software Token for Windows DLL Loading Error Lets Remote  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3: RSA SecurID Software Token for Windows DLL Loading Error 3: RSA SecurID Software Token for Windows DLL Loading Error Lets Remote Users Execute Arbitrary Code U-063: RSA SecurID Software Token for Windows DLL Loading Error Lets Remote Users Execute Arbitrary Code December 16, 2011 - 8:00am Addthis PROBLEM: RSA SecurID Software Token for Windows DLL Loading Error Lets Remote Users Execute Arbitrary Code. PLATFORM: RSA SecurID Software Token 4.1 for Microsoft Windows ABSTRACT: A remote user can cause the target application to execute arbitrary code on the target user's system. reference LINKS: SecurityTracker Alert ID: 1026426 ESA-2011-039 Secunia Advisory: SA45665 Securityfocus Advisory CVE-2011-4141 RSA Online Fraud Resource Center IMPACT ASSESSMENT: High Discussion: A vulnerability was reported in RSA SecurID Software Token. A remote user

364

U-063: RSA SecurID Software Token for Windows DLL Loading Error Lets Remote  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

63: RSA SecurID Software Token for Windows DLL Loading Error 63: RSA SecurID Software Token for Windows DLL Loading Error Lets Remote Users Execute Arbitrary Code U-063: RSA SecurID Software Token for Windows DLL Loading Error Lets Remote Users Execute Arbitrary Code December 16, 2011 - 8:00am Addthis PROBLEM: RSA SecurID Software Token for Windows DLL Loading Error Lets Remote Users Execute Arbitrary Code. PLATFORM: RSA SecurID Software Token 4.1 for Microsoft Windows ABSTRACT: A remote user can cause the target application to execute arbitrary code on the target user's system. reference LINKS: SecurityTracker Alert ID: 1026426 ESA-2011-039 Secunia Advisory: SA45665 Securityfocus Advisory CVE-2011-4141 RSA Online Fraud Resource Center IMPACT ASSESSMENT: High Discussion: A vulnerability was reported in RSA SecurID Software Token. A remote user

365

U-016: Cisco IOS Software HTTP Service Loading Denial of Service  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

16: Cisco IOS Software HTTP Service Loading Denial of Service 16: Cisco IOS Software HTTP Service Loading Denial of Service Vulnerability U-016: Cisco IOS Software HTTP Service Loading Denial of Service Vulnerability October 21, 2011 - 9:00am Addthis PROBLEM: Cisco IOS Software HTTP Service Loading Denial of Service Vulnerability . PLATFORM: Cisco IOS Software ABSTRACT: An unauthenticated, remote attacker could exploit this vulnerability to cause a targeted device to stop responding, resulting in a DoS condition. reference LINKS: CISCO Security Intelligence Operations IntelliShield ID: 24436 CVE-2011-2586 IMPACT ASSESSMENT: Medium Discussion: Cisco IOS Software contains a vulnerability that could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on a targeted device. The vulnerability is due to improper

366

Changes in the real price of electricity: implications for higher load growth  

SciTech Connect

While real electricity prices have increased over the last decade, they have declined relative to oil and natural gas. As a result, electricity has increased its share of the total energy market. Many believe these price trends will not continue as new base-load plants come on line. They state that the real price of electricity will increase disproportionately with respect to other energy forms, resulting in reduced levels of load growth and a loss of market share. The authors of this article disagree, and instead argue that: (1) the real price of electricity will decline over the 1980s; (2) electricity prices will not lose recent competitive gains relative to oil and natural gas; and (3) electricity's market share will continue to increase, and load growth will exceed the 3% average of the 1970s. They conclude that the potential exists for a 4 to 5% load growth scenario for the balance of the 1980s. 5 references, 2 tables.

Siegel, J.R.; Sillin, J.O.

1983-09-15T23:59:59.000Z

367

FFTF and Advanced Reactors Transition Program Resource Loaded Schedule  

SciTech Connect

This Resource Load Schedule (RLS) addresses two missions. The Advanced Reactors Transition (ART) mission, funded by DOE-EM, is to transition assigned, surplus facilities to a safe and compliant, low-cost, stable, deactivated condition (requiring minimal surveillance and maintenance) pending eventual reuse or D&D. Facilities to be transitioned include the 309 Building Plutonium Recycle Test Reactor (PRTR) and Nuclear Energy Legacy facilities. This mission is funded through the Environmental Management (EM) Project Baseline Summary (PBS) RL-TP11, ''Advanced Reactors Transition.'' The second mission, the Fast Flux Test Facility (FFTF) Project, is funded through budget requests submitted to the Office of Nuclear Energy, Science and Technology (DOE-NE). The FFTF Project mission is maintaining the FFTF, the Fuels and Materials Examination Facility (FMEF), and affiliated 400 Area buildings in a safe and compliant standby condition. This mission is to preserve the condition of the plant hardware, software, and personnel in a manner not to preclude a plant restart. This revision of the Resource Loaded Schedule (RLS) is based upon the technical scope in the latest revision of the following project and management plans: Fast Flux Test Facility Standby Plan (Reference 1); Hanford Site Sodium Management Plan (Reference 2); and 309 Building Transition Plan (Reference 4). The technical scope, cost, and schedule baseline is also in agreement with the concurrent revision to the ART Fiscal Year (FY) 2001 Multi-Year Work Plan (MYWP), which is available in an electronic version (only) on the Hanford Local Area Network, within the ''Hanford Data Integrator (HANDI)'' application.

GANTT, D.A.

2000-10-31T23:59:59.000Z

368

Commercial Reference Building: Supermarket | OpenEI  

Open Energy Info (EERE)

Supermarket Supermarket Dataset Summary Description Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus simulation software. Included here is data pertaining to the reference building type Supermarket for each of the 16 climate zones, and each of three construction categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings.The dataset includes four key components: building summary, zone summary, location summary and a picture. Building summary includes details about: form, fabric, and HVAC. Zone summary includes details such as: area, volume, lighting, and occupants for all types of zones in the building. Location summary includes key building information as it pertains to each climate zone, including: fabric and HVAC details, utility costs, energy end use, and peak energy demand.In total, DOE developed 16 reference building types that represent approximately 70% of commercial buildings in the U.S.; for each type, building models are available for each of the three construction categories. The commercial reference buildings (formerly known as commercial building benchmark models) were developed by the U.S. Department of Energy (DOE), in conjunction with three of its national laboratories.Additional data is available directly from DOE's Energy Efficiency & Renewable Energy (EERE) Website, including EnergyPlus software input files (.idf) and results of the EnergyPlus simulations (.html).

369

Radwaste Desk Reference: Volume 5: Transportation Update  

Science Conference Proceedings (OSTI)

This volume of the Radwaste Desk Reference contains fundamental practical and regulatory information on the transportation of radioactive waste. Because its information is based entirely on industry practice, the work can serve as an extensive "how-to" manual for both the newcomer and the experienced radwaste professional.

2000-03-10T23:59:59.000Z

370

Hearing Conservation Program 1.0 Reference  

E-Print Network (OSTI)

Hearing Conservation Program 1.0 Reference California Code of Regulations, Title 8, Article 105, Fullerton to establish and maintain effective noise control and hearing conservation programs designed by University policy and State law. 4.0 Scope The Hearing Conservation Program affects all employees exposed

de Lijser, Peter

371

Commercial Reference Building: Warehouse | OpenEI  

Open Energy Info (EERE)

Warehouse Warehouse Dataset Summary Description Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus simulation software. Included here is data pertaining to the reference building type Warehouse for each of the 16 climate zones, and each of three construction categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings.The dataset includes four key components: building summary, zone summary, location summary and a picture. Building summary includes details about: form, fabric, and HVAC. Zone summary includes details such as: area, volume, lighting, and occupants for all types of zones in the building. Location summary includes key building information as it pertains to each climate zone, including: fabric and HVAC details, utility costs, energy end use, and peak energy demand.In total, DOE developed 16 reference building types that represent approximately 70% of commercial buildings in the U.S.; for each type, building models are available for three categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings. The commercial reference buildings (formerly known as commercial building benchmark models) were developed by the U.S. Department of Energy (DOE), in conjunction with three of its national laboratories.Additional data is available directly from DOE's Energy Efficiency & Renewable Energy (EERE) Website, including EnergyPlus software input files (.idf) and results of the EnergyPlus simulations (.html).

372

Xyce parallel electronic simulator : reference guide.  

SciTech Connect

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide. The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. It is targeted specifically to run on large-scale parallel computing platforms but also runs well on a variety of architectures including single processor workstations. It also aims to support a variety of devices and models specific to Sandia needs. This document is intended to complement the Xyce Users Guide. It contains comprehensive, detailed information about a number of topics pertinent to the usage of Xyce. Included in this document is a netlist reference for the input-file commands and elements supported within Xyce; a command line reference, which describes the available command line arguments for Xyce; and quick-references for users of other circuit codes, such as Orcad's PSpice and Sandia's ChileSPICE.

Mei, Ting; Rankin, Eric Lamont; Thornquist, Heidi K.; Santarelli, Keith R.; Fixel, Deborah A.; Coffey, Todd Stirling; Russo, Thomas V.; Schiek, Richard Louis; Warrender, Christina E.; Keiter, Eric Richard; Pawlowski, Roger Patrick

2011-05-01T23:59:59.000Z

373

Refining visualization reference model for context information  

Science Conference Proceedings (OSTI)

Context-awareness can be used to decrease the need for interaction with a mobile device. This is increasingly important since the functionality of mobile devices and personal digital assistants gets more and more complex while the input and output capabilities ... Keywords: Context awareness, Hand-held devices, Information visualization, Mobile phones, Visualization reference model

Antti Aaltonen; Juha Lehikoinen

2005-11-01T23:59:59.000Z

374

Heap reference analysis using access graphs  

Science Conference Proceedings (OSTI)

Despite significant progress in the theory and practice of program analysis, analyzing properties of heap data has not reached the same level of maturity as the analysis of static and stack data. The spatial and temporal structure of stack and static ... Keywords: Aliasing, data flow analysis, heap references, liveness

Uday P. Khedker; Amitabha Sanyal; Amey Karkare

2007-11-01T23:59:59.000Z

375

Positional reference system for ultraprecision machining  

DOE Patents (OSTI)

A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of position interferometers and part contour description data inputs to calculate error components for each axis of movement and output them to corresponding axis drives with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

Arnold, Jones B. (Knoxville, TN); Burleson, Robert R. (Clinton, TN); Pardue, Robert M. (Knoxville, TN)

1982-01-01T23:59:59.000Z

376

Positional reference system for ultraprecision machining  

DOE Patents (OSTI)

A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

1980-09-12T23:59:59.000Z

377

ITS 1.5 Reference Manual  

E-Print Network (OSTI)

This reference manual consists of two parts. The first (sections 1 through 6) is intended for those who are either interested in the ITS 1.5 time sharing monitor for its own sake or who wish to write machine language ...

Eastlake, D.

1969-07-01T23:59:59.000Z

378

ITS 1.5 Reference Manual  

E-Print Network (OSTI)

This reference manual consists of two parts. The first (sections 1 through 6) is intended for those who are either interested in the ITS 1.5 time sharing monitor for its own sake or who wish to write machine language ...

Eastlake, D.

1968-06-01T23:59:59.000Z

379

Programs (ASD(NCB)) References: See Enclosure  

E-Print Network (OSTI)

accordance with the authority in DoDD 5134.01 (Reference (c)) to update the responsibilities and functions, relationships, and authorities of the ASD(NCB), under the Under Secretary of Defense for Acquisition, Technology, and Logistics (USD(AT&L)). 2. APPLICABILITY. This Directive applies to OSD, the Military Departments, the Office of

unknown authors

2013-01-01T23:59:59.000Z

380

ECUT energy data reference series: boilers  

SciTech Connect

Information on the population and fuel consumption of water-tube, fire-tube and cast iron boilers is summarized. The use of each boiler type in the industrial and commercial sector is examined. Specific information on each boiler type includes (for both 1980 and 2000) the average efficiency of the boiler, the capital stock, the amount of fuel consumed, and the activity level as measured by operational load factor.

Chockie, A.D.; Johnson, D.R.

1984-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Temporal Reference Algorithms versus Spatial Reference Algorithms forSmart Antennas  

Science Conference Proceedings (OSTI)

This paper compares algorithms from three different classes of adaptation schemes for smart antennas – the switched beam approach, a Temporal-Reference (TR) technique based on Direct Matrix Inversion or Least Squares adaptation, and a Spatial-Reference ... Keywords: adaptation algorithms, angular spread, comparison, mutual coupling, smart antennas

Josef Fuhl; Ernst Bonek

1999-05-01T23:59:59.000Z

382

CSNI Project for Fracture Analyses of Large-Scale International Reference Experiments (FALSIRE II)  

SciTech Connect

A summary of Phase II of the Project for FALSIRE is presented. FALSIRE was created by the Fracture Assessment Group (FAG) of the OECD/NEA`s Committee on the Safety of Nuclear Installations (CNSI) Principal Working Group No. 3. FALSIRE I in 1988 assessed fracture methods through interpretive analyses of 6 large-scale fracture experiments in reactor pressure vessel (RPV) steels under pressurized- thermal-shock (PTS) loading. In FALSIRE II, experiments examined cleavage fracture in RPV steels for a wide range of materials, crack geometries, and constraint and loading conditions. The cracks were relatively shallow, in the transition temperature region. Included were cracks showing either unstable extension or two stages of extensions under transient thermal and mechanical loads. Crack initiation was also investigated in connection with clad surfaces and with biaxial load. Within FALSIRE II, comparative assessments were performed for 7 reference fracture experiments based on 45 analyses received from 22 organizations representing 12 countries. Temperature distributions in thermal shock loaded samples were approximated with high accuracy and small scatter bands. Structural response was predicted reasonably well; discrepancies could usually be traced to the assumed material models and approximated material properties. Almost all participants elected to use the finite element method.

Bass, B.R.; Pugh, C.E.; Keeney, J. [Oak Ridge National Lab., TN (United States); Schulz, H.; Sievers, J. [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) mbH, Koeln (Gemany)

1996-11-01T23:59:59.000Z

383

On Load Balancing in a Dense Wireless  

E-Print Network (OSTI)

We study the load balancing problem in a dense wireless multihop network, where a typical path consists of large number of hops, i.e., the spatial scales of a typical distance between source and destination, and mean distance between the neighbouring nodes are strongly separated. In this limit, we present a general framework for analysing the traffic load resulting from a given set of paths and traffic demands. We formulate the load balancing problem as a minmax problem and give two lower bounds for the achievable minimal maximum traffic load. The framework is illustrated by an example of uniformly distributed traffic demands in a unit disk with a few families of paths given in advance. With these paths we are able to decrease the maximum traffic load by factor of 33 40% depending on the assumptions. The obtained traffic load level also comes quite near the tightest lower bound.

Multihop Network Esa; Esa Hyytiä

2006-01-01T23:59:59.000Z

384

Profile Guided Load Marking for Memory Renaming  

E-Print Network (OSTI)

Memory operations remain a significant bottleneck in dynamically scheduled pipelined processors, due in part to the inability to statically determine the existence of memory address dependencies. Hardware memory renaming techniques have been proposed which predict which stores a load might be dependent upon. These prediction techniques can be used to speculatively forward a value from a predicted store dependency to a load through a value prediction table; however, these techniques require large and time-consuming hardware tables. In this paper we propose a software-guided approach for identifying dependencies between store and load instructions and the Load Marking (LM) architecture to communicate these dependencies to the hardware. Compiler analysis and profiles are used to find important store/load relationships, and these relationships are identified during execution via hints or an n-bit tag. For those loads that are not marked for renaming, we then use additional profiling inform...

Glenn Reinman; Brad Calder; Dean Tullsen; Gary Tyson; Todd Austin

1998-01-01T23:59:59.000Z

385

Wind loading on solar collectors  

DOE Green Energy (OSTI)

The present design methodology for the determination of wind loading on the various solar collectors has been reviewed and assessed. The total force coefficients of flat plates of aspect ratios 1.0 and 3.0, respectively, at various angles of attack obtained by using the guidelines of the ANSI A58.1-1982, have been compared with those obtained by using the methodology of the ASCE Task Committee, 1961, and the experimental results of the full-scale test of heliostats by Peglow. The turbulent energy spectra, currently employed in the building code, are compared with those of Kaimal et al., Lumley, and Ponofsky for wind velocities of 20.0 m/s and 40.24 m/s at an elevation of 9.15 m. The longitudinal spectra of the building code overestimates the Kaimal spectra in the frequency range of 0.007 Hz to 0.08 Hz and underestimates beyond the frequency of 0.08 Hz. The peak angles of attack, on the heliostat, stowed in horizontal position, due to turbulent vertical and lateral components of wind velocity, have been estimated by using Daniel's methodology for three wind velocities and compared with the value suggested by the code. The experimental results of a simple test in the laboratory indicate the feasibility of decreasing the drag forces of the flat plate by reducing the solidity ratio.

Bhaduri, S.; Murphy, L.M.

1985-06-01T23:59:59.000Z

386

Assessment of Industrial-Sector Load Shapes  

Science Conference Proceedings (OSTI)

The load shapes of industrial-sector customers are becoming increasingly important for utility forecasting, marketing, and demand-side management planning and evaluation activities. This report analyzes load shapes for various industry segments and investigates the transfer of these load shapes across service territories. This report is available only to funders of Program 101A or 101.001. Funders may download this report at http://my.primen.com/Applications/DE/Community/index.asp .

1993-02-18T23:59:59.000Z

387

Trends in electric utility load duration curves  

SciTech Connect

This report documents the development and analysis of annual and quarterly load duration curves for each of the 10 Federal regions. The report describes analyses performed to test for changes in load duration curve shapes over time. These analyses are intended to aid the electric utility analyses and modeling activities of the Energy Information Administration (EIA) by expanding the understanding of current and expected load duration curve shapes. 7 figs., 13 tabs.

1984-12-01T23:59:59.000Z

388

Loads, capacity, and failure rate modeling  

SciTech Connect

Both failure rate and load capacity (stress-strength) interferenece methodologies are employed in the reliability analysis at nuclear facilities. Both of the above have been utilized in a heuristic failure rate model in terms of load capacity inference. Analytical solutions are used to demonstrate that infant mortality and random aging failures may be expressed implicity in terms of capacity variability, load variability, and capacity deterioration, and that mode interactions play a role in the formation of the bathtub curve for failure rates.

Lewis, E.E.; Chen, Hsin-Chieh

1994-12-31T23:59:59.000Z

389

1991 Pacific Northwest Loads and Resources Study.  

SciTech Connect

This study establishes the Bonneville Power Administration's (BPA) planning basis for supplying electricity to BPA customers. The Loads and Resources Study is presented in three documents: (1) this summary of federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. This analysis updates our 1990 study. BPS's long-range planning incorporates resource availability with a range of forecasted electrical consumption. The forecasted future electrical demands-firm loads--are subtracted from the projected capability of existing resources to determine whether BPA and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, then additional conservation, contract purchases, or generating resources will be needed to meet load growth. This study analyzes the Pacific Northwest's projected loads and available generating resources in two parts: (1) the loads and resources of the federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional profile, which includes loads and resources in addition to the federal system. This study presents the federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for 1992- 2012.

United States. Bonneville Power Administration.

1991-12-01T23:59:59.000Z

390

Reservoir compaction loads on casings and liners  

Science Conference Proceedings (OSTI)

Pressure drawdown due to production from a reservoir causes compaction of the reservoir formation which induces axial and radial loads on the wellbore. Reservoir compaction loads increase during the production life of a well, and are greater for deviated wells. Presented here are casing and liner loads at initial and final pressure drawdowns for a particular reservoir and at well deviation angles of 0 to 45 degrees.

Wooley, G.R.; Prachner, W.

1984-09-01T23:59:59.000Z

391

NORMAL LOAD BEARING BY SITE SPECIFIC CANISTER  

Science Conference Proceedings (OSTI)

The overall purpose of this calculation is to perform a preliminary analysis of the Site Specific Canister/Basket, subject to static gravity loads that include the self weight of the Canister Shell, the Basket, the Spent Nuclear Fuel, the Shield Plug and the related hardware, so that the loads are approximately known for sizing purposes. Based on these loads the stress levels in various components of the Site Specific Canister/Basket are evaluated.

NA

2005-03-23T23:59:59.000Z

392

Measured Peak Equipment Loads in Laboratories  

SciTech Connect

This technical bulletin documents measured peak equipment load data from 39 laboratory spaces in nine buildings across five institutions. The purpose of these measurements was to obtain data on the actual peak loads in laboratories, which can be used to rightsize the design of HVAC systems in new laboratories. While any given laboratory may have unique loads and other design considerations, these results may be used as a 'sanity check' for design assumptions.

Mathew, Paul A.

2007-09-12T23:59:59.000Z

393

21-PWR WASTE PACKAGE WITH ABSORBER PLATES LOADING CURVE EVALUATION  

Science Conference Proceedings (OSTI)

The objective of this calculation is to evaluate the required minimum burnup as a function of initial pressurized water reactor (PWR) assembly enrichment that would permit loading of spent nuclear fuel into the 21 PWR waste package with absorber plates design as provided in Attachment IV. This calculation is an example of the application of the methodology presented in the ''Disposal Criticality Analysis Methodology Topical Report'' (YMP 2003). The scope of this calculation covers a range of enrichments from 0 through 5.0 weight percent U-235, and a burnup range of 0 through 45 GWd/MTU. Higher burnups were not necessary because 45 GWd/MTU was high enough for the loading curve determination. This activity supports the validation of the use of burnup credit for commercial spent nuclear fuel applications. The intended use of these results will be in establishing PWR waste package configuration loading specifications. Limitations of this evaluation are as follows: (1) The results are based on burnup credit for actinides and selected fission products as proposed in YMP (2003, Table 3-1) and referred to as the ''Principal Isotopes''. Any change to the isotope listing will have a direct impact on the results of this report. (2) The results are based on 1.5 wt% Gd in the Ni-Gd Alloy material and having no tuff inside the waste package. If the Gd loading is reduced or a process to introduce tuff inside the waste package is defined, then this report would need to be reevaluated based on the alternative materials. This calculation is subject to the ''Quality Assurance Requirements and Description'' (QARD) (DOE 2004) because it concerns engineered barriers that are included in the ''Q-List'' (BSC 2004k, Appendix A) as items important to safety and waste isolation.

J.M. Scaglione

2004-12-17T23:59:59.000Z

394

Load relaxation studies of zircaloy-4  

SciTech Connect

The results of the present work have shown (1) the load relaxation data of Zircaloy-4 in the temperature range of 200/sup 0/C to 385/sup 0/C can be represented by the phenomenological model based on Hart's plastic equation of state; (2) the room temperature load relaxation data reflect the effects of deformation twinning; (3) at higher temperatures the load relaxation data suggest the contribution of grain boundary sliding; and (4) the effects of strain aging can be identified based on the load relaxation data.

Huang, F.H.; Sabol, G.P.; McDonald, S.G.; Li, C.Y.

1976-01-01T23:59:59.000Z

395

OpenEI Community - load profile  

Open Energy Info (EERE)

/0 en Commercial and /0 en Commercial and Residential Hourly Load Data Now Available on OpenEI! http://en.openei.org/community/blog/commercial-and-residential-hourly-load-data-now-available-openei <span class=Load data" src="http://en.openei.org/community/files/load_data_figure_small.jpg" style="width:527px; height:285px" title="" />Image source: NREL 

Files: 
application/zip icon

396

NREL: Vehicle Ancillary Loads Reduction - Laboratory Capabilities  

NLE Websites -- All DOE Office Websites (Extended Search)

VALR Lab. NREL's Vehicle Ancillary Loads Reduction Laboratory houses ADAM, our advanced thermal manikin, as well as a passenger compartment climate simulator, testing equipment...

397

Building Energy Software Tools Directory: Load Express  

NLE Websites -- All DOE Office Websites (Extended Search)

Create project files with Load Express in just 4 easy steps. Select a weather profile, enter simulation parameters, define the zonesrooms in the building and create air handler...

398

Effect of Nonproportional Loadings on Ductile Fracture  

Science Conference Proceedings (OSTI)

Abstract Scope, This study aims at understanding the effects of load path ... D-2: Forging of Magnesium Alloy by Impulsive Energy at Room Temperature.

399

Thermoplastic Flour Containing Eugenol-loaded Chitosan ...  

Science Conference Proceedings (OSTI)

Presentation Title, Thermoplastic Flour Containing Eugenol-loaded Chitosan ... Properties of AA 7075 Reinforced with Nanometric ZrO2 Obtained by Ball-milling.

400

Building Energy Software Tools Directory : HVAC Residential Load...  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Residential Load Calcs HD for the iPad Back to Tool HVAC Residential Load Calcs HD screenshot HVAC Residential Load Calcs HD screenshot HVAC Residential Load Calcs HD...

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Methods for Analyzing Electric Load Shape and its Variability  

E-Print Network (OSTI)

15 Figure 12: Load profile by day of week, averaged over thebetween the average load profile and the profile of a givenfrom the average load profile. Figure 12: Load profile by

Price, Philip

2010-01-01T23:59:59.000Z

402

The Ozone Dilemma: a reference handbook (Contemporary World Issues Series)  

E-Print Network (OSTI)

Dilemma: a reference handbook By David E. Newton Reviewed byDilemma: a reference handbook (Contemporary World IssuesThe Ozone Dilemma: a reference handbook is targeted at both

Li, Haipeng

1997-01-01T23:59:59.000Z

403

Annual Energy Outlook 2011 Reference Case  

Gasoline and Diesel Fuel Update (EIA)

AEO2012 Early Release Rollout Presentation AEO2012 Early Release Rollout Presentation Paul H. Nitze School of Advanced International Studies John Hopkins University January 23, 2012 | Washington, DC Howard Gruenspecht, Acting Administrator Annual Energy Outlook 2012 Early Release Reference Case Key results from the AEO2012 Reference case, which assumes current laws remain unchanged 2 Howard Gruenspecht AEO2012, January 23, 2012 * Projected growth of energy use slows over the projection period reflecting an extended economic recovery and increasing energy efficiency in end-use applications * Domestic crude oil production increases, reaching levels not experienced since 1994 by 2020 * With modest economic growth, increased efficiency, growing domestic production, and continued adoption of nonpetroleum liquids, net

404

Ocean - Quick Reference | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

- Quick Reference - Quick Reference Ocean Data Tools Technical Guide Map Gallery Regional Planning Feedback Ocean You are here Data.gov » Communities » Ocean Quick Ref 1) Q: How do I upload metadata into Data.gov? A: Federal Agencies: Data.gov is organized into separate catalogs to provide access to three classes of published, publicly accessible federal data and related access tools and services: "raw" data, geodata and applications, each with specific distinguishing characteristics. Although the selection criteria, approval, and submission process differ by department and agency, the following highlights the Data.gov submission process. Nomination of data or application Although any individual or organization may suggest a dataset or application for promotion to Data.gov, primary responsibility rests with

405

IBM References | Argonne Leadership Computing Facility  

NLE Websites -- All DOE Office Websites (Extended Search)

Data Transfer Data Transfer Debugging & Profiling Performance Tools & APIs Software & Libraries IBM References Intrepid/Challenger/Surveyor Tukey Eureka / Gadzooks Policies Documentation Feedback Please provide feedback to help guide us as we continue to build documentation for our new computing resource. [Feedback Form] IBM References Contents IBM Redbooks A2 Processor Manual QPX Vector Instruction Set Architecture XL Compiler Documentation MASS Documentation Back to top IBM Redbooks IBM System Blue Gene Solution: Blue Gene/Q Application Development Manual - Application and library developers wants this one. This documents options for MPI, OpenMP, and other features of interest to most users. IBM System Blue Gene Solution: Blue Gene/Q Code Development and Tools Interface - Low-level tools; developers may find this useful.

406

REScheck Residnetial Plan Review Quick Reference Guide  

NLE Websites -- All DOE Office Websites (Extended Search)

RESIDENTIAL PLAN REVIEW RESIDENTIAL PLAN REVIEW QUICK REFERENCE GUIDE Plan review for energy code compliance can be conducted quickly and efficiently. The U.S. Department of Energy's REScheck Compliance Software is designed to create simplified compliance certificates that can be easily reviewed by enforcement personnel. This Quick Reference Guide will guide you, step-by-step, through a typical plan review process. There are three basic steps for conducting a building energy code plan review: Step 1: Verify the documentation has been correctly prepared. Step 2: Verify the levels of efficiency shown on the plans meet or exceed that shown in the documentation. Step 3: Verify all of the information to conduct a field inspection is included in the plans or documentation for the inspector to use on site.

407

to refer your readers to any other  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

refer your readers to any other refer your readers to any other forms of communication that you've created for your organization. You can also use this space to remind readers to mark their calendars for a regular event, such as a breakfast meeting for vendors every third Tuesday of the month, or a biannual charity auction. If space is available, this is a good place to insert a clip art image or some other graphic. This story can fit 175-225 words. If your newsletter is folded and mailed, this story will appear on the back. So, it's a good idea to make it easy to read at a glance. A question and answer session is a good way to quickly capture the at- tention of readers. You can either compile questions that you've re-

408

EERE Program Management Quick Reference Guide  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

a companion to the Office of Energy Efficiency and a companion to the Office of Energy Efficiency and Renewable Energy (EERE) Program Management Reference Guide. It provides an overall description of the EERE program management structure, defines EERE program and project management roles and responsibilities, lays out the general sequence of activities in the program management cycle, and introduces the EERE Strategic Management System (SMS) and the EERE Information and Business Management Systems - Corporate Planning System (CPS), EERE Information System (EIS), and the Systems Approach to Grants Administration for Windows (WinSAGA). Quick references to the Guide and other sources of information of related program management information are provided throughout in information boxes associated within the text.

409

OFFICE OF FAIR TRADING TERMS OF REFERENCE  

E-Print Network (OSTI)

The OFT, in exercise of its powers under sections 131 and 133 of the Enterprise Act 2002 (the Act), hereby makes a reference to the Competition Commission for an investigation into the supply of local bus services. In accordance with section 133(2) and (3)(a) of the Act the Competition Commission shall confine its investigation to the effects of features of such market or markets for local bus services as exist in connection with the supply of such services in United Kingdom excluding Northern Ireland and London.' The OFT has reasonable grounds for suspecting that a feature or a combination of features of the market or markets for the supply of local bus services in the UK excluding Northern Ireland and London prevents, restricts or distorts competition. For the purposes of this reference: 'local bus services ' means all bus services, both commercial 2 and tendered,3 which

John Fingleton

2010-01-01T23:59:59.000Z

410

Lorentz Transformation from Symmetry of Reference Principle  

E-Print Network (OSTI)

The Lorentz Transformation is traditionally derived requiring the Principle of Relativity and lightspeed universality. While the latter can be relaxed, the Principle of Relativity is seen as core to the transformation. The present letter relaxes both statements to the weaker, Symmetry of Reference Principle. Thus the resulting Lorentz transformation and its consequences (time dilatation, length contraction) are, in turn, effects of how we manage space and time.

M. Dima

2006-01-01T23:59:59.000Z

411

Radwaste Desk Reference: Volume 4: Mixed Waste  

Science Conference Proceedings (OSTI)

Mixed waste management has been a significant concern to nuclear utilities due to the lack of available treatment and disposal capacity. This volume of the Radwaste Desk Reference contains fundamental practical and regulatory information on the management of mixed low level waste. Because its information is based entirely on industry practice, the work can serve as an extensive "how-to" manual for both the newcomer and the experienced radwaste professional responsible for mixed waste.

1995-12-31T23:59:59.000Z

412

CRITICALITY SAFETY QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

9, 2010 Page 1 of 47 9, 2010 Page 1 of 47 Criticality Safety Qualification Standard Reference Guide 2010 For use with DOE-STD 1173-2009, CRITICALITY SAFETY FUNCTIONAL AREA QUALIFICATION STANDARD September 9, 2010 Page 2 of 47 PURPOSE....................................................................................................................... 5 SCOPE............................................................................................................................ 5 1. Criticality safety personnel must demonstrate a working-level knowledge of the fission process. .......................................................................................................... 6 2. Criticality safety personnel must demonstrate a working-level knowledge of the

413

Insulator Reference Book: Chapter 1: Insulator Fundamentals  

Science Conference Proceedings (OSTI)

This technical update report presents a draft first chapter of the Electric Power Research Institute (EPRI) Insulator Reference Book, which is being developed to give utility transmission engineers a comprehensive information resource on all aspects of high-voltage insulators.BackgroundHigh-voltage insulators are an essential part of the power delivery system. They ensure the safe transmission of electricity from generating stations to substations, where the ...

2013-12-19T23:59:59.000Z

414

EPRI Live Working Reference Book Edition 2  

Science Conference Proceedings (OSTI)

This report contains updated information on the 2012 edition of the National Electrical Safety Code (NESC) and on glass insulators that became available after publication of the first edition of the Tan Book (Electric Power Research Institute [EPRI] report 1018974) in 2009. The 2009 first edition of the this report was a fully revised, updated, and expanded version of the Live Working Guide for Overhead Lines (EPRI report 1008747), published in 2004. The new EPRI Live Working Reference Book provides the ...

2011-11-02T23:59:59.000Z

415

Reference Poster: Turbine Bearing Damage Mechanisms  

Science Conference Proceedings (OSTI)

Damage to turbine and generator bearings accounts for a significant amount of lost generation in the power industry. There are numerous known damage mechanisms affecting these bearings, and as part of EPRI’s technology transfer efforts, we have developed a reference poster. This poster provides clear, concise, and visual information for a wide variety of mechanisms and is meant to supplement related EPRI projects. By providing an overview of various issues as well as information on how to ...

2012-10-04T23:59:59.000Z

416

Lorentz Transformation from Symmetry of Reference Principle  

E-Print Network (OSTI)

The Lorentz Transformation is traditionally derived requiring the Principle of Relativity and light-speed universality. While the latter can be relaxed, the Principle of Relativity is seen as core to the transformation. The present letter relaxes both statements to the weaker, Symmetry of Reference Principle. Thus the resulting Lorentz transformation and its consequences (time dilatation, length contraction) are, in turn, effects of how we manage space and time.

M. Dima

2006-05-24T23:59:59.000Z

417

NETL: Coal & Coal Biomass to Liquids - Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Shelf Coal and CoalBiomass to Liquids Reference Shelf Documents Papers Presentations DOCUMENTS 2012 Technology Readiness Assessment-Analysis of Active Research Portfolio...

418

Surface Temperature Humidity Reference System Handbook - November 2005  

SciTech Connect

The Surface Temperature and Humidity Reference (SURTHREF) system is intended to provide accurate reference values of ambient temperature and relative humidity for comparison with radiosonde prelaunch values.

MT Ritsche

2005-11-30T23:59:59.000Z

419

Plutonium Certified Reference Materials Price List | U.S. DOE...  

Office of Science (SC) Website

Plutonium Certified Reference Materials Price List New Brunswick Laboratory (NBL) NBL Home About Programs Certified Reference Materials Prices and Certificates Ordering Information...

420

Reference Buildings by Building Type: Small Hotel | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

& Publications Reference Buildings by Climate Zone and Representative City: 2A Houston, Texas Reference Buildings by Climate Zone and Representative City: 3B Los Angeles,...

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

FAQS Reference Guide - Emergency Management | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emergency Management FAQS Reference Guide - Emergency Management This reference guide addresses the competency statements in the January 2004 edition of DOE-STD-1177-2004,...

422

The Promise of Load Balancing the Parameterization of Moist Convection Using a Model Data Load Index  

Science Conference Proceedings (OSTI)

The parameterization of physical processes in atmospheric general circulation models contributes to load imbalances among individual processors of message-passing distributed-multiprocessor systems. Load imbalances increase the overall time to ...

S. P. Muszala; D. A. Connors; J. J. Hack; G. Alaghband

2006-04-01T23:59:59.000Z

423

Estimating Demand Response Load Impacts: Evaluation of Baseline Load Models for Non-  

E-Print Network (OSTI)

, and the Office of Electricity Delivery and Energy Reliability, Permitting, Siting and Analysis of the ULBNL-63728 Estimating Demand Response Load Impacts: Evaluation of Baseline Load Models for Non .............................................................................................................. 9 4. Baseline Profile (BLP) Models

424

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network (OSTI)

Abbreviations ADDF ALM AMR CSP DOE DR ELRP ETS EWH FERC HVa Curtailment Service Provider (CSP) at PJM’s request. LBNLof load control tests. The CSP collected hourly load data

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

425

Large heavy-duty gas turbines for base-load power generation and heat cogeneration  

SciTech Connect

The predominant role of large gas turbines has shifted from peaking-load duty to midrange and base-load electric power generation, especially within combined-cycle plants. Such applications require heavy-duty industrial gas turbines to ensure the same high reliability and availability for continuous service as the associated steam turbines. It is also important that the gas turbines be designed for low maintenance to minimize the necessary outage times and costs for component repair and replacement. The basic design principles and applications of Model V94 gas turbines are discussed with special reference to highly reliable and economic bulk power generation.

Joyce, J.S.

1985-01-01T23:59:59.000Z

426

Decentralized agent-based underfrequency load shedding  

Science Conference Proceedings (OSTI)

As part of the transition to a smart grid efforts are being made to decentralize control of electric power systems and modernize protection schemes that are currently in use. One specific application of distributed control is underfrequency load shedding ... Keywords: UFLS, Underfrequency load shedding, intelligent agents

Sara Mullen; Getiria Onsongo

2010-12-01T23:59:59.000Z

427

Design Ground Snow Loads for Ohio  

Science Conference Proceedings (OSTI)

The weight of snow with a mean recurrence interval of 50 years, called the design ground snow load, is used by engineers and planners to estimate the weight of snow that roofs must be designed to support National maps of ground snow load have ...

Thomas W. Schmidlin; Dennis J. Edgell; Molly A. Delaney

1992-06-01T23:59:59.000Z

428

Apparatus for loading a band saw blade  

DOE Patents (OSTI)

A band saw blade is loaded between pairs of guide wheels upon tensioning the blade by guiding the blade between pairs of spaced guide plates which define converging slots that converge toward the guide wheels. The approach is particularly useful in loading blades on underwater band saw machines used to cut radioactive materials. 2 figs.

Reeves, S.R.

1990-03-20T23:59:59.000Z

429

Protecting consumer privacy from electric load monitoring  

Science Conference Proceedings (OSTI)

The smart grid introduces concerns for the loss of consumer privacy; recently deployed smart meters retain and distribute highly accurate profiles of home energy use. These profiles can be mined by Non Intrusive Load Monitors (NILMs) to expose much of ... Keywords: load monitor, privacy, smart meter

Stephen McLaughlin; Patrick McDaniel; William Aiello

2011-10-01T23:59:59.000Z

430

Quantifying the effectiveness of load balance algorithms  

Science Conference Proceedings (OSTI)

Load balance is critical for performance in large parallel applications. An imbalance on today's fastest supercomputers can force hundreds of thousands of cores to idle, and on future exascale machines this cost will increase by over a factor of a thousand. ... Keywords: framework, load balance, modeling, performance, simulation

Olga Pearce; Todd Gamblin; Bronis R. de Supinski; Martin Schulz; Nancy M. Amato

2012-06-01T23:59:59.000Z

431

Household type load's effects on photovoltaic systems  

Science Conference Proceedings (OSTI)

The solar energy is one of the most important energy sources available because, besides the fact that it is not polluting the environment and it helps to the reduction of green house effect, it is free of charge and it can be easily converted to other ... Keywords: A.C. loads, D.C. loads, compact fluorescent lamp, photovoltaic system, power LED

Nazmi Ekren; Nevzat Onat; Safak Saglam

2008-12-01T23:59:59.000Z

432

Load Modeling Using a Measurement Based Approach  

Science Conference Proceedings (OSTI)

This report summarizes the work performed in the second phase of a multi-year collaborative load modeling research program that was initiated in 2004. The measurement based approach described in this report will help utilities to develop representative load models using suitable measurement data.

2007-12-17T23:59:59.000Z

433

Apparatus for loading a band saw blade  

DOE Patents (OSTI)

A band saw blade is loaded between pairs of guide wheels upon tensioning the blade by guiding the blade between pairs of spaced guide plates which define converging slots that converge toward the guide wheels. The approach is particularly useful in loading blades on underwater band saw machines used to cut radioactive materials.

Reeves, Steven R. (49 Williams Ave., West Valley, NY 14171)

1990-01-01T23:59:59.000Z

434

1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design. Appendix F. 1-GWh electrical system design  

DOE Green Energy (OSTI)

Two circuit configurations for reducing the installed converter power and cost of high-power converter systems that operate in a constant-power mode over a wide current and voltage range are suggested and analyzed.

Boenig, H.J.

1979-09-01T23:59:59.000Z

435

Plug Load Energy Analysis: The Role of Plug Loads in LEED Certification  

E-Print Network (OSTI)

benchmark and is bound to change as the proportion of plug load energy use grows in commercial buildings.

Fuertes, Gwen; Schiavon, Stefano

2013-01-01T23:59:59.000Z

436

Combustion Impacts of Flexible Operation: Low Load, Load Following, and Increased Staging Impact on Boiler Tubes  

Science Conference Proceedings (OSTI)

Over the past few years, coal-fired generating units have changed from stable base load operation to flexible operation, including periods of prolonged low-load operation. These changes in operation can have various adverse effects on all plant equipment, particularly in older units and may impact their ability to operate without tube failures due to elevated levels of fireside corrosion and circumferential cracking. This report discusses the combustion-related impacts of low-load, load-following, ...

2013-12-23T23:59:59.000Z

437

Combi Systems for Low Load homes  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

text styles text styles Combi Systems for Low Load Homes Center for Energy and Environment, NorthernSTAR, Ben Schoenbauer * Low load homes are more common than ever. * Typical space heating and DHW equipment have capacities larger than necessary * A single heating plant could provide high efficiency heat at lower costs, increased durability and improved combustion safety Context Technical Approach * A condensing water heater and hydronic air handler will used to provide space and water heating loads in almost 300 weatherized homes. * System specifications, sizing, and installation optimization guidelines were all developed. * Contractor capability was developed in MN market, but may not be developed in all local. 4 Recommended Guidance * Determine peak load on system: - Space heating design load (ie 40,000 Btu/hr)

438

Using Utility Load Data to Estimate Demand for Space Cooling and Potential for Shiftable Loads  

SciTech Connect

This paper describes a simple method to estimate hourly cooling demand from historical utility load data. It compares total hourly demand to demand on cool days and compares these estimates of total cooling demand to previous regional and national estimates. Load profiles generated from this method may be used to estimate the potential for aggregated demand response or load shifting via cold storage.

Denholm, P.; Ong, S.; Booten, C.

2012-05-01T23:59:59.000Z

439

An Analysis of Load Balancing Technology - Comparing LSF with other Load Balancing Software Packages  

E-Print Network (OSTI)

This paper examines what the load balancing needs of organizations are today, the solution LSF (Load Sharing Facility) provides for them, and how other currently available load balancing products compare to LSF. Jean Suplick (suplick@cxsoft.convex.com) CXSOFT Richardson, Texas January 1994 Why clusters?

Jean Suplick

1994-01-01T23:59:59.000Z

440

An Evaluation of the HVAC Load Potential for Providing Load Balancing Service  

Science Conference Proceedings (OSTI)

This paper investigates the potential of providing aggregated intra-hour load balancing services using heating, ventilating, and air-conditioning (HVAC) systems. A direct-load control algorithm is presented. A temperature-priority-list method is used to dispatch the HVAC loads optimally to maintain consumer-desired indoor temperatures and load diversity. Realistic intra-hour load balancing signals were used to evaluate the operational characteristics of the HVAC load under different outdoor temperature profiles and different indoor temperature settings. The number of HVAC units needed is also investigated. Modeling results suggest that the number of HVACs needed to provide a {+-}1-MW load balancing service 24 hours a day varies significantly with baseline settings, high and low temperature settings, and the outdoor temperatures. The results demonstrate that the intra-hour load balancing service provided by HVAC loads meet the performance requirements and can become a major source of revenue for load-serving entities where the smart grid infrastructure enables direct load control over the HAVC loads.

Lu, Ning

2012-09-30T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

End-use load control for power system dynamic stability enhancement  

SciTech Connect

Faced with the prospect of increasing utilization of the transmission and distribution infrastructure without significant upgrade, the domestic electric power utility industry is investing heavily in technologies to improve network dynamic performance through a program loosely referred to as Flexible AC Transmission System (FACTS). Devices exploiting recent advances in power electronics are being installed in the power system to offset the need to construct new transmission lines. These devices collectively represent investment potential of several billion dollars over the next decade. A similar development, designed to curtail the peak loads and thus defer new transmission, distribution, and generation investment, falls under a category of technologies referred to as demand side management (DSM). A subset of broader conservation measures, DSM acts directly on the load to reduce peak consumption. DSM techniques include direct load control, in which a utility has the ability to curtail specific loads as conditions warrant. A novel approach has been conceived by Pacific Northwest National Laboratory (PNNL) to combine the objectives of FACTS and the technologies inherent in DSM to provide a distributed power system dynamic controller. This technology has the potential to dramatically offset major investments in FACTS devices by using direct load control to achieve dynamic stability objectives. The potential value of distributed versus centralized grid modulation has been examined by simulating the western power grid under extreme loading conditions. In these simulations, a scenario is analyzed in which active grid stabilization enables power imports into the southern California region to be increased several hundred megawatts beyond present limitations. Modeling results show distributed load control is up to 30 percent more effective than traditional centralized control schemes in achieving grid stability.

Dagle, J.E.; Winiarski, D.W.; Donnelly, M.K.

1997-02-01T23:59:59.000Z

442

1993 Solid Waste Reference Forecast Summary  

SciTech Connect

This report, which updates WHC-EP-0567, 1992 Solid Waste Reference Forecast Summary, (WHC 1992) forecasts the volumes of solid wastes to be generated or received at the US Department of Energy Hanford Site during the 30-year period from FY 1993 through FY 2022. The data used in this document were collected from Westinghouse Hanford Company forecasts as well as from surveys of waste generators at other US Department of Energy sites who are now shipping or plan to ship solid wastes to the Hanford Site for disposal. These wastes include low-level and low-level mixed waste, transuranic and transuranic mixed waste, and nonradioactive hazardous waste.

Valero, O.J.; Blackburn, C.L. [Westinghouse Hanford Co., Richland, WA (United States); Kaae, P.S.; Armacost, L.L.; Garrett, S.M.K. [Pacific Northwest Lab., Richland, WA (United States)

1993-08-01T23:59:59.000Z

443

Department of Energy Construction Safety Reference Guide  

SciTech Connect

DOE has adopted the Occupational Safety and Health Administration (OSHA) regulations Title 29 Code of Federal Regulations (CFR) 1926 ``Safety and Health Regulations for Construction,`` and related parts of 29 CFR 1910, ``Occupational Safety and Health Standards.`` This nonmandatory reference guide is based on these OSHA regulations and, where appropriate, incorporates additional standards, codes, directives, and work practices that are recognized and accepted by DOE and the construction industry. It covers excavation, scaffolding, electricity, fire, signs/barricades, cranes/hoists/conveyors, hand and power tools, concrete/masonry, stairways/ladders, welding/cutting, motor vehicles/mechanical equipment, demolition, materials, blasting, steel erection, etc.

Not Available

1993-09-01T23:59:59.000Z

444

Definition: Loading Monitor | Open Energy Information  

Open Energy Info (EERE)

data via a communication network in real- or near real-time.1 Related Terms sustainability References www.smartgrid.govsitesdefaultfilespdfsdescriptionofassets.p...

445

Definition: Load Shift Factor | Open Energy Information  

Open Energy Info (EERE)

transmission facility or monitored Flowgate.1 Also Known As LSF Related Terms transmission lines, transmission line, flowgate, smart grid References Glossary of...

446

Variability of Load and Net Load in Case of Large Scale Distributed Wind Power  

Science Conference Proceedings (OSTI)

Large scale wind power production and its variability is one of the major inputs to wind integration studies. This paper analyses measured data from large scale wind power production. Comparisons of variability are made across several variables: time scale (10-60 minute ramp rates), number of wind farms, and simulated vs. modeled data. Ramp rates for Wind power production, Load (total system load) and Net load (load minus wind power production) demonstrate how wind power increases the net load variability. Wind power will also change the timing of daily ramps.

Holttinen, H.; Kiviluoma, J.; Estanqueiro, A.; Gomez-Lazaro, E.; Rawn, B.; Dobschinski, J.; Meibom, P.; Lannoye, E.; Aigner, T.; Wan, Y. H.; Milligan, M.

2011-01-01T23:59:59.000Z

447

Organizational Reference Groups: A Missing Perspective on Social Context  

Science Conference Proceedings (OSTI)

This paper introduces and empirically explores the concept of an organizational reference group: the set of people an individual perceives as belonging to his or her work environment that defines the social world of work in which he or she engages. The ... Keywords: career achievement, career expectations, career referents, cognition, organizational reference groups, perception, reference groups, social context, social networks

Barbara S. Lawrence

2006-01-01T23:59:59.000Z

448

Automatic Detection of Unsafe Component Loadings  

E-Print Network (OSTI)

Dynamic loading of software components (e.g., libraries or modules) is a widely used mechanism for improved system modularity and flexibility. Correct component resolution is critical for reliable and secure software execution, however, programming mistakes may lead to unintended or even malicious components to be resolved and loaded. In particular, dynamic loading can be hijacked by placing an arbitrary file with the specified name in a directory searched before resolving the target component. Although this issue has been known for quite some time, it was not considered serious because exploiting it requires access to the local file system on the vulnerable host. Recently such vulnerabilities started to receive considerable attention as their remote exploitation became realistic; it is now important to detect and fix these vulnerabilities. In this paper, we present the first automated technique to detect vulnerable and unsafe dynamic component loadings. Our analysis has two phases: 1) apply dynamic binary instrumentation to collect runtime information on component loading (online phase); and 2) analyze the collected information to detect vulnerable component loadings (offline phase). For evaluation, we implemented our technique to detect vulnerable and unsafe DLL loadings in popular Microsoft Windows software. Our results show that unsafe DLL loading is prevalent and can lead to serious security threats. Our tool detected more than 1,700 unsafe DLL loadings in 28 widely used software and discovered serious attack vectors for remote code execution. Microsoft has opened a Microsoft Security Response Center (MSRC) case on our reported issues and is working with us and other affected software vendors to develop necessary patches.

Taeho Kwon; Zhendong Su

2010-01-01T23:59:59.000Z

449

Load Data Analysis and PowerShape Training: Strategic Load Research and Advanced Topics in Load Profiling for Settlements  

Science Conference Proceedings (OSTI)

Load shapes, representing usage patterns in the electric and gas industry, are a key factor in energy company operations and management. In the emerging restructured energy market, retail energy suppliers market energy to final customers and must arrange for electricity generation or gas delivery to meet their customers' needs. EPRI and Primen sponsored a workshop in September 2000 that addressed a range of issues associated with load shapes, including modeling, profiling for retail market settlement, re...

2000-12-20T23:59:59.000Z

450

Space cooling demands from office plug loads  

Science Conference Proceedings (OSTI)

Undersizing space cooling systems for office buildings can result in uncomfortable and angry tenants on peak cooling days. However, oversizing wastes money because more capacity is installed than is needed, and oversized systems have a lower energy efficiency which makes operating costs higher than necessary. Oversizing can adversely affect comfort as well, because oversized systems may provide poor humidity control and large temperature variations. Correct system sizing requires estimating building heat loads accurately. This paper discusses the heat load generated by the plug load, which includes any electrical equipment that is plugged into outlets.

Komor, P.

1997-12-01T23:59:59.000Z

451

Template:ReferenceForValue | Open Energy Information  

Open Energy Info (EERE)

ReferenceForValue ReferenceForValue Jump to: navigation, search This is the ReferenceForValue template. It is used by forms to assign a references to values supplied in the form. This template will generate the additional form field necessary to collect the reference information for the provided form field. Parameters Fieldname - The name of the form field containing the value to be referenced. Note: Parameters can be called in numerical order, or using parameter name. Dependencies Widget:ShowRefFieldsButton - Necessary to toggle the display of the reference fields, which are hidden by default. Usage Use within a form construct like this: {{ReferenceForValue|MyField}} to create a field called "Reference for MyField" which will collect a reference and apply it to the form's template as |ReferenceForMyField=

452

Pressure vessel and piping codes. Technical basis for revised reference crack growth rate curves for pressure boundary steels in LWR environment  

SciTech Connect

Since the inception of the pressure vessel and piping codes the reference fatigue crack growth rate curves have been contained in Appendix A of Sect. XI. The curves have been designed to be applicable to carbon and low alloy pressure vessel steels exposed to either air or light water reactor coolant environments. Data obtained over the past several years have shown a different behavior of these steels in the light water reactor environment than that predicted by the present reference curve. A revised set of reference curves has been formulated, incorporating a new curve shape as well as a dependency of growth rate on R ratio (minimum load/maximum load). This work provides the background and justification for such a revision, details the methodology used to develop the revised curves, and includes an evalution of the adequacy and impact of the revised curves as compared with the single curve which they replace. 24 references.

Bamford, W.H.

1980-11-01T23:59:59.000Z

453

Impact of load type on microgrid stability  

E-Print Network (OSTI)

Microgrids show great promise as a means of integrating distributed generation sources into the public grid distribution system. In order to provide uninterrupted,high quality power to local loads, microgrids must have the ...

Monnin, Jared P

2012-01-01T23:59:59.000Z

454

High density load bearing insulation peg  

DOE Patents (OSTI)

A high density peg is disclosed which can support a large load and exhibits excellent thermal resistance produced by a method wherein the peg is made in compliance with specified conditions of time, temperature and pressure. 4 figs.

Nowobilski, J.J.; Owens, W.J.

1985-01-29T23:59:59.000Z

455

Passive load control for large wind turbines.  

DOE Green Energy (OSTI)

Wind energy research activities at Sandia National Laboratories focus on developing large rotors that are lighter and more cost-effective than those designed with current technologies. Because gravity scales as the cube of the blade length, gravity loads become a constraining design factor for very large blades. Efforts to passively reduce turbulent loading has shown significant potential to reduce blade weight and capture more energy. Research in passive load reduction for wind turbines began at Sandia in the late 1990's and has moved from analytical studies to blade applications. This paper discusses the test results of two Sandia prototype research blades that incorporate load reduction techniques. The TX-100 is a 9-m long blade that induces bend-twist coupling with the use of off-axis carbon in the skin. The STAR blade is a 27-m long blade that induces bend-twist coupling by sweeping the blade in a geometric fashion.

Ashwill, Thomas D.

2010-05-01T23:59:59.000Z

456

S-Band Loads for SLAC Linac  

SciTech Connect

The S-Band loads on the current SLAC linac RF system were designed, in some cases, 40+ years ago to terminate 2-3 MW peak power into a thin layer of coated Kanthal material as the high power absorber [1]. The technology of the load design was based on a flame-sprayed Kanthal wire method onto a base material. During SLAC linac upgrades, the 24 MW peak klystrons were replaced by 5045 klystrons with 65+ MW peak output power. Additionally, SLED cavities were introduced and as a result, the peak power in the current RF setup has increased up to 240 MW peak. The problem of reliable RF peak power termination and RF load lifetime required a careful study and adequate solution. Results of our studies and three designs of S-Band RF load for the present SLAC RF linac system is discussed. These designs are based on the use of low conductivity materials.

Krasnykh, A.; Decker, F.-J.; /SLAC; LeClair, R.; /INTA Technologies, Santa Clara

2012-08-28T23:59:59.000Z

457

High density load bearing insulation peg  

DOE Patents (OSTI)

A high density peg which can support a large load and exhibits excellent thermal resistance produced by a method wherein the peg is made in compliance with specified conditions of time, temperature and pressure.

Nowobilski, Jeffert J. (Orchard Park, NY); Owens, William J. (Kenmore, NY)

1985-01-01T23:59:59.000Z

458

T-573: Windows Remote Desktop Client DLL Loading Error Lets Remote Users  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3: Windows Remote Desktop Client DLL Loading Error Lets Remote 3: Windows Remote Desktop Client DLL Loading Error Lets Remote Users Execute Arbitrary Code T-573: Windows Remote Desktop Client DLL Loading Error Lets Remote Users Execute Arbitrary Code March 9, 2011 - 3:05pm Addthis PROBLEM: Vulnerability in Remote Desktop Client Could Allow Remote Code Execution. PLATFORM: Remote Desktop Connection Client Version(s): 5.2, 6.0, 6.1, 7.0 ABSTRACT: A vulnerability was reported in Windows Remote Desktop Client. A remote user can cause arbitrary code to be executed on the target user's system. reference LINKS: Microsoft Security Bulletin MS11-017 SecurityTracker Alert ID:1025172 CVE-2011-0029 IMPACT ASSESSMENT: Moderate Discussion: A remote user can create a specially crafted DLL file on a remote share (e.g., WebDAV, SMB share). When the target user opens a valid Remote

459

NREL EFM DATA: Disaggregated Residential Load Cost Data | OpenEI  

Open Energy Info (EERE)

EFM DATA: Disaggregated Residential Load Cost Data EFM DATA: Disaggregated Residential Load Cost Data Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( http://205.254.135.24/cneaf/electricity/page/eia861.html), e.g. field A14 references "34", which is the EIA Utility ID for the City of Abbeville, South Carolina Utility Company. Within each data set per utility resides different types of equipment, miscellaneous electric load plugs, and appliances found in "common households" given by costs broken out by months. All data within each cell is a floating point number with the metric of dollars/month, e.g. 0.46 equals $0.46/month of interest. Please note: That costs given are only for electricity costs not gas!

460

Peak Load Shifting by Thermal Energy Storage  

Science Conference Proceedings (OSTI)

This technical update from the Electric Power Research Institute (EPRI) reviews the technology of storing energy in hot water and explores the potential for implementing this form of thermal energy storagethrough means of smart electric water heatersas a way to shift peak load on the electric grid. The report presents conceptual background, discusses strategies for peak load shifting and demand response, documents a series of laboratory tests conducted on a representative model of smart water heater, and...

2011-12-14T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Gearbox Reliability Collaborative (GRC) Description and Loading  

SciTech Connect

This document describes simulated turbine load cases in accordance to the IEC 61400-1 Ed.3 standard, which is representative of the typical wind turbine design process. The information presented herein is intended to provide a broad understanding of the gearbox reliability collaborative 750kW drivetrain and turbine configuration. In addition, fatigue and ultimate strength drivetrain loads resulting from simulations are presented. This information provides the bases for the analytical work of the gearbox reliability collaborative effort.

Oyague, F.

2011-11-01T23:59:59.000Z

462

Load apparatus and method for bolt-loaded compact tension test specimen  

DOE Patents (OSTI)

A bolt-loaded compact tension test specimen load apparatus includes: a) a body having first and second opposing longitudinal ends, the first end comprising an externally threaded portion sized to be threadedly received within the test specimen threaded opening; b) a longitudinal loading rod having first and second opposing longitudinal ends, the loading rod being slidably received in a longitudinal direction within the body internally through the externally threaded portion and slidably extending longitudinally outward of the body first longitudinal end; c) a force sensitive transducer slidably received within the body and positioned to engage relative to the loading rod second longitudinal end; and d) a loading bolt threadedly received relative to the body, the loading bolt having a bearing end surface and being positioned to bear against the transducer to forcibly sandwich the transducer between the loading bolt and loading rod. Also disclosed is a method of in situ determining applied force during crack propagation in a bolt-loaded compact tension test specimen.

Buescher, Jr., Brent J. (Idaho Falls, ID); Lloyd, W. Randolph (Idaho Falls, ID); Ward, Michael B. (Idaho Falls, ID); Epstein, Jonathan S. (Idaho Falls, ID)

1997-01-01T23:59:59.000Z

463

Annual Energy Outlook 2011 Reference Case  

Gasoline and Diesel Fuel Update (EIA)

Center for Strategic and International Studies Center for Strategic and International Studies Howard Gruenspecht, Acting Administrator September 19, 2011 | Washington, DC International Energy Outlook 2011 Key findings in the IEO2011 Reference case 2 Howard Gruenspecht CSIS, September 19, 2011 * World energy consumption increases by 53% between 2008 and 2035 with half of the increase attributed to China and India * Renewables are the world's fastest-growing energy source, at 2.8% per year; renewables share of world energy grows to roughly 15% in 2035 * Fossil fuels continue to supply almost 80% of world energy use in 2035 * Liquid fuels remain the largest energy source worldwide through 2035, but the oil share of total energy declines to 28% in 2035, as sustained high oil prices dampen demand and encourage fuel

464

Semantic Features for Classifying Referring Search Terms  

SciTech Connect

When an internet user clicks on a result in a search engine, a request is submitted to the destination web server that includes a referrer field containing the search terms given by the user. Using this information, website owners can analyze the search terms leading to their websites to better understand their visitors needs. This work explores some of the features that can be used for classification-based analysis of such referring search terms. We present initial results for the example task of classifying HTTP requests countries of origin. A system that can accurately predict the country of origin from query text may be a valuable complement to IP lookup methods which are susceptible to the obfuscation of dereferrers or proxies. We suggest that the addition of semantic features improves classifier performance in this example application. We begin by looking at related work and presenting our approach. After describing initial experiments and results, we discuss paths forward for this work.

May, Chandler J.; Henry, Michael J.; McGrath, Liam R.; Bell, Eric B.; Marshall, Eric J.; Gregory, Michelle L.

2012-05-11T23:59:59.000Z

465

Review: Stability of nonlinear masonry members under combined load  

Science Conference Proceedings (OSTI)

Under examination is the post buckling of unreinforced load-bearing masonry walls or piers subject to a combined load consisting of a uniformly distributed axial load and a concentrated eccentric load at the top end. Fixed free-ended prismatic columns ... Keywords: Brick walls, Combined load, Instability, Masonry, No-tension material, Nonlinear constitutive law

Igino Mura

2008-08-01T23:59:59.000Z

466

Conditional model of peak and minimum loads and the load duration curve for electricity  

SciTech Connect

This report presents a model that extends the traditional model of electricity demand to account for intra-period load variation, the kind of variation that is important for evaluating marginal-cost-reflecting price structures. The time-of-day rate is one such price structure. The traditional model of electricity demand explains inter-period demand variation. It says nothing about load variation. The report explains how a model that integrates with previous studies of electricity demand might be formulated. It specifies two concrete models within this framework and estimates them for a number of different utility companies. The model's within-sample-period performance in predicting peak loads is presented for one version of the model extension along with estimations for other variations. In addition a number of plots of actual load distributions, a summation of load variation information, against the actual load distributions, are presented and used to evaluate the performance of specific models.

Trimble, J.L.; Stallings, D.E.; Thomas, B.

1980-05-01T23:59:59.000Z

467

Comprehensive aerological reference data set (CARDS)  

SciTech Connect

The possibility of anthropogenic climate change has reached the attention of Government officials and researchers. However, one cannot study climate change without climate data. The CARDS project will produce high-quality upper-air data for the research community and for policy-makers. The authors intend to produce a dataset which is: easy to use, as complete as possible, as free of random errors as possible. They will also attempt to identify biases and remove them whenever possible. In this report, they relate progress toward their goal. They created a robust new format for archiving upper-air data, and designed a relational database structure to hold them. The authors have converted 13 datasets to the new format and have archived over 10,000,000 individual soundings from 10 separate data sources. They produce and archive a metadata summary of each sounding they load. They have researched station histories, and have built a preliminary upper-air station history database. They have converted station-sorted data from their primary database into synoptic-sorted data in a parallel database. They have tested and will soon implement an advanced quality-control procedure, capable of detecting and often repairing errors in geopotential height, temperature, humidity, and wind. This unique quality-control method uses simultaneous vertical, horizontal, and temporal checks of several meteorological variables. It can detect errors other methods cannot.

Eskridge, R.E.; Polansky, A.C.; Alduchov, O.A. [National Oceanic and Atmospheric Administration, Asheville, NC (United States). National Climatic Data Center] [and others

1997-11-01T23:59:59.000Z

468

Harmonic approaches to non-intrusive load diagnostics  

E-Print Network (OSTI)

The Non-Intrusive Load Monitor (NILM) is a system that monitors, records and processes voltage and current measurements to establish the operating characteristics of individual loads on a load center from a single aggregate ...

Fuller, Ashley E. (Ashley Eliot)

2008-01-01T23:59:59.000Z

469

Building Energy Software Tools Directory: HVAC Residential Load...  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Residential Load Calcs HD for the iPad Carmel Software logo HVAC Residential Load Calcs HD is a comprehensive HVAC heating and cooling load calculation application for the...

470

IMPROVEMENTS TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION  

E-Print Network (OSTI)

IMPROVEMENTS TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION PROCEDURE By BEREKET TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION PROCEDURE Dissertation Approved: Dr. Jeffrey D- Original RTSM.......................................................153 4.4.1 RTSM Peak Design Cooling Load

471

Direct versus Facility Centric Load Control for Automated Demand Response  

E-Print Network (OSTI)

actions to influence load profiles of their customers atISO needs to influence the load profile of a Facility arebe a specific target load profile to be achieved while in

Piette, Mary Ann

2010-01-01T23:59:59.000Z

472

Property Models for High Waste Loaded Hanford HLW Glasses  

High Waste Loading Was Shown for Selected Wastes Examples of the high loaded glasses Al 2O 3 loadings in the 24-26 wt% range compared to <15% for a

473

CRYSTALLINE CERAMIC WASTE FORMS: REFERENCE FORMULATION REPORT  

Science Conference Proceedings (OSTI)

The research conducted in this work package is aimed at taking advantage of the long term thermodynamic stability of crystalline ceramics to create more durable waste forms (as compared to high level waste glass) in order to reduce the reliance on engineered and natural barrier systems. Durable ceramic waste forms that incorporate a wide range of radionuclides have the potential to broaden the available disposal options and to lower the storage and disposal costs associated with advanced fuel cycles. Assemblages of several titanate phases have been successfully demonstrated to incorporate radioactive waste elements, and the multiphase nature of these materials allows them to accommodate variation in the waste composition. Recent work has shown that they can be successfully produced from a melting and crystallization process. The objective of this report is to explain the design of ceramic host systems culminating in a reference ceramic formulation for use in subsequent studies on process optimization and melt property data assessment in support of FY13 melter demonstration testing. The waste stream used as the basis for the development and testing is a combination of the projected Cs/Sr separated stream, the Trivalent Actinide - Lanthanide Separation by Phosphorous reagent Extraction from Aqueous Komplexes (TALSPEAK) waste stream consisting of lanthanide fission products, the transition metal fission product waste stream resulting from the transuranic extraction (TRUEX) process, and a high molybdenum concentration with relatively low noble metal concentrations. In addition to the combined CS/LN/TM High Mo waste stream, variants without Mo and without Mo and Zr were also evaluated. Based on the results of fabricating and characterizing several simulated ceramic waste forms, two reference ceramic waste form compositions are recommended in this report. The first composition targets the CS/LN/TM combined waste stream with and without Mo. The second composition targets with CS/LN/TM combined waste stream with Mo and Zr removed. Waste streams that contain Mo must be produced in reducing environments to avoid Cs-Mo oxide phase formation. Waste streams without Mo have the ability to be melt processed in air. A path forward for further optimizing the processing steps needed to form the targeted phase assemblages is outlined in this report. Processing modifications including melting in a reducing atmosphere, and controlled heat treatment schedules are anticipated to improve the targeted elemental partitioning.

Brinkman, K.; Fox, K.; Marra, J.

2012-05-15T23:59:59.000Z

474

Load cell having strain gauges of arbitrary location  

DOE Patents (OSTI)

A load cell utilizes a plurality of strain gauges mounted upon the load cell body such that there are six independent load-strain relations. Load is determined by applying the inverse of a load-strain sensitivity matrix to a measured strain vector. The sensitivity matrix is determined by performing a multivariate regression technique on a set of known loads correlated to the resulting strains. Temperature compensation is achieved by configuring the strain gauges as co-located orthogonal pairs.

Spletzer, Barry (Albuquerque, NM)

2007-03-13T23:59:59.000Z

475

How and why distribution loads vary  

SciTech Connect

Because the maximum-use rates of gas customers having differing appliance combinations do not coincide, a distribution system's peak-hour flow rate depends on the relative proportions of the load contributed by the appliances of all the different types of residential, commercial, and industrial customers. The maximum load on Central Hudson's distribution system coincides with the maximum hourly gas flow rate for all residential space-heating purposes; however, Central Hudson analyzes the peak-hour load of its commercial and industrial customers individually. The gas-system sendout presented as a sendout-duration curve is a convenient way to show how these various loads determine gas requirements and to compare the economics of alternative supply methods. The sendout-duration curve consists of long-term weather data plotted against time intervals of 1-365 days. If the threshold temperature and the heating load per degree-day are known, the curve allows the calculation of both normal and design annual peakshaving quantities.

Haber, D.P.

1980-01-01T23:59:59.000Z

476

Status of load management storage demonstrations  

DOE Green Energy (OSTI)

DOE is funding a nationwide demonstration of electric load management through the use of utility-controlled, customer-side thermal energy storage for residential space conditioning. The general concept of the projects was developed with the assistance of a broadly based working group drawn from the utility industry. This paper presents the current status of these demonstrations. Ten demonstrations are underway - five heat storage and five cool storage - using between 30 and 50 near-commercial thermal storage devices. The installations and experimental program are designed to: (1) collect reliable load research data for assessing the impact on the utility system; (2) delineate and solve installation problems; (3) establish maintainability; (4) illuminate customer and utility acceptance; and (5) generate cost data. The results obtained are expected to assist utilities in making local load-management decisions, to assist DOE in establishing priorities for R and D efforts in load management, and to provide objective information related to the electric system impact, energy conservation, and cost-effectiveness of this form of load management.

Long, H M; Mohre, D L

1979-01-01T23:59:59.000Z

477

A practical approach for electricity load forecasting  

E-Print Network (OSTI)

Abstract—This paper is a continuation of our daily energy peak load forecasting approach using our modified network which is part of the recurrent networks family and is called feed forward and feed back multi context artificial neural network (FFFB-MCANN). The inputs to the network were exogenous variables such as the previous and current change in the weather components, the previous and current status of the day and endogenous variables such as the past change in the loads. Endogenous variable such as the current change in the loads were used on the network output. Experiment shows that using endogenous and exogenous variables as inputs to the FFFB-MCANN rather than either exogenous or endogenous variables as inputs to the same network produces better results. Experiments show that using the change in variables such as weather components and the change in the past load as inputs to the FFFB-MCANN rather than the absolute values for the weather components and past load as inputs to the same network has a dramatic impact and produce better accuracy.

T. Rashid; T. Kechadi

2005-01-01T23:59:59.000Z

478

R FPGA Motor Control Reference Design  

E-Print Network (OSTI)

With the growing complexity of motor and motion control applications, it becomes apparent that a Field Programmable Gate Array (FPGA) offers significant advantage over the off the shelf Application Specific Standard Product (ASSP) solutions in the areas of performance, flexibility and inventory control. With an FPGA, calculations that would normally consume large amounts of CPU time when implemented in software may be hardware accelerated. Using hardware acceleration allows for more functionality within the system software. Custom motor drive interfaces such as PWM can be developed easily, quickly and at low cost. Additionally, because of full configurability, the same FPGA can be used in various product ranges, reducing the need to maintain inventory for multiple devices. This application note describes the Spartan™-3 device based FPGA Motor Control Reference Design. This design utilizes the MicroBlaze ™ 32-bit CPU soft core, floating point unit, and associated memory subsystems, SPI communications interface, and IP specifically designed to control brushless DC (BLDC) and three phase AC induction motors. Design files can be found at www.xilinx.com/bvdocs/appnotes/xapp808.zip.

Craig Hackney

2005-01-01T23:59:59.000Z

479

SAPHIRE 8 Volume 2 - Technical Reference  

Science Conference Proceedings (OSTI)

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of computer programs that were developed to create and analyze probabilistic risk assessment (PRAs). Herein information is provided on the principles used in the construction and operation of Version 8.0 of the SAPHIRE system. This report summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms used to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that apply for various assumptions concerning reparability and mission time. It defines the measures of basic event importance that SAPHIRE can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by this program to generate random basic event probabilities from various distributions. Also covered are enhance capabilities such as seismic analysis, Workspace algorithms, cut set "recovery," end state manipulation, and use of "compound events."

C. L. Smith; S. T. Wood; W. J. Galyean; J. A. Schroeder; M. B. Sattison

2011-03-01T23:59:59.000Z

480

Biomass Scenario Model Documentation: Data and References  

SciTech Connect

The Biomass Scenario Model (BSM) is a system dynamics model that represents the entire biomass-to-biofuels supply chain, from feedstock to fuel use. The BSM is a complex model that has been used for extensive analyses; the model and its results can be better understood if input data used for initialization and calibration are well-characterized. It has been carefully validated and calibrated against the available data, with data gaps filled in using expert opinion and internally consistent assumed values. Most of the main data sources that feed into the model are recognized as baseline values by the industry. This report documents data sources and references in Version 2 of the BSM (BSM2), which only contains the ethanol pathway, although subsequent versions of the BSM contain multiple conversion pathways. The BSM2 contains over 12,000 total input values, with 506 distinct variables. Many of the variables are opportunities for the user to define scenarios, while others are simply used to initialize a stock, such as the initial number of biorefineries. However, around 35% of the distinct variables are defined by external sources, such as models or reports. The focus of this report is to provide insight into which sources are most influential in each area of the supply chain.

Lin, Y.; Newes, E.; Bush, B.; Peterson, S.; Stright, D.

2013-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "references awea1 loading" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Reference repository design concept for bedded salt  

Science Conference Proceedings (OSTI)

A reference design concept is presented for the subsurface portions of a nuclear waste repository in bedded salt. General geologic, geotechnical, hydrologic and geochemical data as well as descriptions of the physical systems are provided for use on generic analyses of the pre- and post-sealing performance of repositories in this geologic medium. The geology of bedded salt deposits and the regional and repository horizon stratigraphy are discussed. Structural features of salt beds including discontinuities and dissolution features are presented and their effect on repository performance is discussed. Seismic hazards and the potential effects of earthquakes on underground repositories are presented. The effect on structural stability and worker safety during construction from hydrocarbon and inorganic gases is described. Geohydrologic considerations including regional hydrology, repository scale hydrology and several hydrological failure modes are presented in detail as well as the hydrological considerations that effect repository design. Operational phase performance is discussed with respect to operations, ventilation system, shaft conveyances, waste handling and retrieval systems and receival rates of nuclear waste. Performance analysis of the post sealing period of a nuclear repository is discussed, and parameters to be used in such an analysis are presented along with regulatory constraints. Some judgements are made regarding hydrologic failure scenarios. Finally, the design and licensing process, consistent with the current licensing procedure is described in a format that can be easily understood.

Carpenter, D.W.; Martin, R.W.

1980-10-08T23:59:59.000Z

482

EIA - Reference Case Projection Tables 1990-2030  

Gasoline and Diesel Fuel Update (EIA)

Tables (1990-2030) Tables (1990-2030) International Energy Outlook 2006 Reference Case Projections Tables (1990-2030) Formats Data Table Titles (1 to 14 complete) Reference Case Projections Tables. Need help, contact the National Energy Information Center at 202-586-8800. Reference Case Projections Tables. Need help, contact the National Energy Information Center at 202-586-8800. Table A1 World Total Primary Energy Consumption by Region, Reference Case Reference Case Projections Tables. Need help, contact the National Energy Information Center at 202-586-8800. Reference Case Projections Tables. Need help, contact the National Energy Information Center at 202-586-8800. Table A2 World Total Energy Consumption by Region and Fuel, Reference Case Reference Case Projections Tables. Need help, contact the National Energy Information Center at 202-586-8800.

483

Renewable Energy Monitoring Evaluation Terms of Reference | Open Energy  

Open Energy Info (EERE)

Renewable Energy Monitoring Evaluation Terms of Reference Renewable Energy Monitoring Evaluation Terms of Reference Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Renewable Energy Monitoring Evaluation Terms of Reference Agency/Company /Organization: World Bank Sector: Energy Focus Area: Renewable Energy Topics: Policies/deployment programs Website: web.worldbank.org/WBSITE/EXTERNAL/TOPICS/EXTENERGY2/EXTRENENERGYTK/0,, References: Renewable Energy Monitoring Evaluation Terms of Reference[1] Resources Design of a Monitoring and Evaluation Plan Audit of Solar Home Systems Project Mid-term Review Panel for Solar Home Systems Project Socio-Economic Survey of the Photovoltaic Pilot Project References ↑ "Renewable Energy Monitoring Evaluation Terms of Reference" Retrieved from "http://en.openei.org/w/index.php?title=Renewable_Energy_Monitoring_Evaluation_Terms_of_Reference&oldid=329154"

484

DOE EVMS Cross Reference Checklist | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE EVMS Cross Reference Checklist More Documents & Publications DOE EVMS CROSS Reference Checklist DOE EVMS Risk Assessment Matrix Microsoft Word - g413.3-10Final5-6-08.doc...

485

EIA - International Energy Outlook 2007-Reference Case Projections...  

Gasoline and Diesel Fuel Update (EIA)

Reference Case Projections by End-Use Sector and Region Data Tables (2004-2030) International Energy Outlook 2007 Reference Case Projections by End-Use Sector and Region Data...

486

Comparison of Building Energy Modeling Programs: Building Loads  

NLE Websites -- All DOE Office Websites (Extended Search)

Comparison of Building Energy Modeling Programs: Building Loads Title Comparison of Building Energy Modeling Programs: Building Loads Publication Type Report LBNL Report Number...

487

The Effect of Daylighting Strategies on Building Cooling Loads...  

NLE Websites -- All DOE Office Websites (Extended Search)

The Effect of Daylighting Strategies on Building Cooling Loads and Overall Energy Performance Title The Effect of Daylighting Strategies on Building Cooling Loads and Overall...

488

Definition: Dispersed Load By Substations | Open Energy Information  

Open Energy Info (EERE)

By Substations Jump to: navigation, search Dictionary.png Dispersed Load By Substations Substation load information configured to represent a system for power flow or system...

489

Methods and apparatus for reduction of asymmetric rotor loads in ...  

A method for reducing load and providing yaw alignment in a wind turbine includes measuring displacements or moments resulting from asymmetric loads on the wind turbine.

490

Building Energy Software Tools Directory: Prophet Load Profiler  

NLE Websites -- All DOE Office Websites (Extended Search)

Shots Keywords energy analysis, load profiling, cost comparison, energy budgeting, rate analysis, data collection, real-time monitoring, load shedding ValidationTesting NA...

491

Energetical factors in power systems with nonlinear loads  

Science Conference Proceedings (OSTI)

Based on the volt-ampere charac- teristic of the nonlinear load, an equivalent circuit, containing linear elements, can be determined. In this way, load-flow and.

492

Used Nuclear Fuel Loading and Structural Performance Under Normal...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Used Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Modeling, Simulation and Experimental Integration RD&D Plan Used Nuclear Fuel Loading...

493

Definition: Direct Control Load Management | Open Energy Information  

Open Energy Info (EERE)

Control Load Management Jump to: navigation, search Dictionary.png Direct Control Load Management Demand-Side Management that is under the direct control of the system operator....

494

Definition: Circuit Peak Load Management | Open Energy Information  

Open Energy Info (EERE)

Circuit Peak Load Management Jump to: navigation, search Dictionary.png Circuit Peak Load Management An application utilizing sensors, information processors, communications, and...

495

Definition: Real-Time Load Transfer | Open Energy Information  

Open Energy Info (EERE)

Real-time load transfer is achieved through real-time feeder reconfiguration and optimization to relieve load on equipment, improve asset utilization, improve distribution...

496

Load Control for System Reliability and Measurement-Based Stability...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Load Control for System Reliability and Measurement-Based Stability Assessment Load Control for System Reliability and Measurement-Based Stability Assessment Research and develop...

497

A comparison of measured wind park load histories with the WISPER and WISPERX load spectra  

DOE Green Energy (OSTI)

The blade-loading histories from two adjacent Micon 65/13 wind turbines are compared with the variable-amplitude test-loading histories known as the WISPER and WISPERX spectra. These standardized loading sequences were developed from blade flapwise load histories taken from nine different horizontal-axis wind turbines operating under a wide range of conditions in Europe. The subject turbines covered a broad spectrum of rotor diameters, materials, and operating environments. The final loading sequences were developed as a joint effort of thirteen different European organizations. The goal was to develop a meaningful loading standard for horizontal-axis wind turbine blades that represents common interaction effects seen in service. In 1990, NREL made extensive load measurements on two adjacent Micon 65/13 wind turbines in simultaneous operation in the very turbulent environment of a large wind park. Further, before and during the collection of the loads data, comprehensive measurements of the statistics of the turbulent environment were obtained at both the turbines under test and at two other locations within the park. The trend to larger but lighter wind turbine structures has made an understanding of the expected lifetime loading history of paramount importance. Experience in the US has shown that the turbulence-induced loads associated with multi-row wind parks in general are much more severe than for turbines operating individually or within widely spaced environments. Multi-row wind parks are much more common in the US than in Europe. In this paper we report on our results in applying the methodology utilized to develop the WISPER and WISPERX standardized loading sequences using the available data from the Micon turbines. While the intended purpose of the WISPER sequences were not to represent a specific operating environment, we believe the exercise is useful, especially when a turbine design is likely to be installed in a multi-row wind park.

Kelley, N.D.

1995-01-01T23:59:59.000Z

498

Estimating Demand Response Load Impacts: Evaluation of Baseline Load Models for Non-Residential Buildings in California  

E-Print Network (OSTI)

This  baseline  load  profile  (BLP)  is  key  to to  as  the  baseline  load  profile  or  BLP  and  is  key actual  and  estimated  load  profiles  look,  Figure  1 

Coughlin, Katie; Piette, Mary Ann; Goldman, Charles; Kiliccote, Sila

2008-01-01T23:59:59.000Z

499

Development of Standard Reference Materials for Vitamins B6 ...  

Science Conference Proceedings (OSTI)

Development of Standard Reference Materials for Vitamins B6 and B12 in Human Serum. Summary: Vitamins are essential ...

2013-03-15T23:59:59.000Z

500

Development of a Standard Reference Material for Vitamin D ...  

Science Conference Proceedings (OSTI)

... Office of Dietary Supplements to develop a Standard Reference Material for ... which incorporates stable isotope labeled internal standards for both ...

2013-03-15T23:59:59.000Z