Powered by Deep Web Technologies
Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

IBM Systems Director Active Energy Manager Installation and User's Guide  

E-Print Network [OSTI]

IBM Systems Director Active Energy Manager Installation and User's Guide Version 4.3 #12;#12;IBM Systems Director Active Energy Manager Installation and User's Guide Version 4.3 #12;ii IBM Systems Director Active Energy Manager: Installation and User's Guide #12;About this book This book provides

2

DOE's New Checklist Helps Plants Assess Energy Management Activities...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

simple checklist can help a facility assess whether Superior Energy Performance (SEP) or ISO 50001 are practical next steps, or if foundational energy management activities...

3

Examining Synergies between Energy Management and Demand Response: A Case Study at Two California Industrial Facilities  

E-Print Network [OSTI]

and Demand Response History Energy Management Activities o #and Demand Response History Energy Management Activities

Olsen, Daniel

2013-01-01T23:59:59.000Z

4

Benchmarking Corporate Energy Management  

E-Print Network [OSTI]

BENCHMARKING CORPORATE ENERGY MANAGEMENT Dr. Douglas L. Norland Director of Research and Industrial Programs Alliance to Save Energy Washington, DC ABSTRACT There is growing interest among energy managers in finding out how their company...'s energy management procedures and perfonnance compare to that of other companies. Energy management involves everything from setting goals and targets to implementing best maintenance practices. This paper, however, discusses benchmarking energy...

Norland, D. L.

5

Energy Management Working Group: Accelerating Energy Management  

E-Print Network [OSTI]

Countries participating in the Global Superior Energy Performance (GSEP) Energy Management Working Group (EMWG) are leveraging their resources and taking collective action to strengthen national and international efforts to facilitate the adoption...

Scheihing, P.

2014-01-01T23:59:59.000Z

6

Sustainable Energy Management Programs  

E-Print Network [OSTI]

Sustainable Energy Management Programs Steve Hanner Allen ISD/TEMA . ESL-KT-14-11-45 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 Starting an Energy Management Program • Recognize need, Elicit District Commitment... • Appoint Energy Manager • Analyze Existing Conditions • Develop Plan • Implement and Monitor Program ESL-KT-14-11-45 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 Sustainable Programs Feature – District Commitment...

Hanner, S.

2014-01-01T23:59:59.000Z

7

Energy Management Systems  

E-Print Network [OSTI]

This presentation will address results from a pilot project with 10 chemical plants on energy management systems and the development of an energy efficiency plant certification program....

Ferland, K.

2007-01-01T23:59:59.000Z

8

Energy Management Webinar Series  

Broader source: Energy.gov [DOE]

Boost your knowledge on how to implement an energy management system through this four-part webinar series from the Superior Energy Performance program. Each webinar introduces various elements of the ISO 50001 energy management standard—based on the Plan-Do-Check-Act approach—and the associated steps of DOE's eGuide for ISO 50001 software tool.

9

Lead By Example with Smart Energy Management (Brochure)  

SciTech Connect (OSTI)

Brochure outlining the mission and activities of the Department of Energy's Federal Energy Management Program, which facilitates the Federal Government's implementation of sound, cost-effective energy management and investment practices to enhance the nation's energy security and environmental stewardship.

Not Available

2009-07-01T23:59:59.000Z

10

Corporate Energy Management Process  

E-Print Network [OSTI]

. May 21-24, 2013 Corporate Energy Management Process 2 ?Brief introduction to BASF ? BASF Corporate Energy Management ? Management Support ? Goals ? Continuous Improvement ? Best Practices ? Recognition ?Summary ESL-IE-13-05-25 Proceedings...-value products ? Intelligent, sustainable system solutions ? 2012 Sales: ?72.1 Billion ? Employees: 110,000 Company overview BASF ? The Chemical Company ESL-IE-13-05-25 Proceedings of the Thrity-Fifth Industrial Energy Technology Conference New Orleans, LA...

Geiger, T.

2013-01-01T23:59:59.000Z

11

Linac Energy Management for LCLS  

SciTech Connect (OSTI)

Linac Energy Management (LEM) is a control system program that scales magnet field set-point settings following a change in beam energy. LEM is necessary because changes in the number, phase, and amplitude of the active klystrons change the beam's rigidity, and therefore, to maintain constant optics, one has to change focusing gradients and bend fields accordingly. This paper describes the basic process, the control system application programs we developed for LEM, and some of the implementation lessons learned at the Linac Coherent Light Source (LCLS).

Chu, Chungming; /SLAC; Iverson, Richard; /SLAC; Krejcik, Patrick; /SLAC; Rogind, Deborah; /SLAC; White, Greg; /SLAC; Woodley, Mark; /SLAC

2012-07-05T23:59:59.000Z

12

Strategies for Successful Energy Management  

Broader source: Energy.gov [DOE]

This presentation, given through the DOE's Technical Assitance Program (TAP), provides information on energy management for the portfolio manager initiative

13

Energy Management and Conservation Plan  

E-Print Network [OSTI]

Energy Management and Conservation Plan December 2005 #12;Texas Transportation Institute December 2005 Energy Management and Conservation Plan Page 2 of 24 Table of Contents Section One: Executive: Reporting Progress #12;Texas Transportation Institute December 2005 Energy Management and Conservation Plan

14

Energy Management Issued: June 2010  

E-Print Network [OSTI]

Energy Management Policy Issued: June 2010 Revised: Responsible Administrative Unit: Finance.0 BACKGROUND AND PURPOSE The Engineering and Energy Management division of the Department of Facilities Management at the Colorado School of Mines ("Mines" or "the school") has developed an Energy Management

15

Energy Management Curriculum Starter Kit  

SciTech Connect (OSTI)

The Energy Management Curriculum Starter Kit was designed to help engineering educators develop and teach energy management courses. Montana State University and Oklahoma State University courses are embodied in the model curriculum given. The curricula offered at many other universities throughout the United States are also presented. The kit was designed specifically to train engineering students to be good energy managers. Courses at both the undergraduate and postgraduate level are presented.

Turner, W.C.

1987-02-01T23:59:59.000Z

16

Energy Management Report November 2014  

E-Print Network [OSTI]

Energy Management Report November 2014 #12; TAMU Energy Management Report it established for reducing its usage of electricity, gasoline, and natural gas: Energy consumption per period from FY02 ­ FY14. The goal in the 2005 Energy Conservation Plan was to achieve an EUI of 275

17

Linking Continuous Energy Management and Open Automated Demand Response  

E-Print Network [OSTI]

Linking Continuous Energy Management and Open AutomatedKeywords: Continuous Energy Management, Automated Demandlinking continuous energy management and continuous

Piette, Mary Ann

2009-01-01T23:59:59.000Z

18

Communications and the Energy Manager  

E-Print Network [OSTI]

developed to aid in the communications needs of such diverse groups. Each group has specific informational requirements that must be fulfilled for the Energy Management Program to be successful. This paper presents some of the methods that the author has...

Cooper, J. I.

19

Energy Management and Information Systems  

E-Print Network [OSTI]

?infrastructure energy?audits,?HVAC?upgrades,? heat?recovery,?etc. Improve?operations processes?and?day?to?day? operations,?retro? commissioning ENERGY?MANAGEMENT?INFORMATION?SYSTEM the?project Hardware ? $3.0?million?investment ? 400+?meters...

Conraud, J.

2013-01-01T23:59:59.000Z

20

Interagency Energy Management Task Force Members  

Broader source: Energy.gov [DOE]

The Interagency Energy Management Task Force is led by the Federal Energy Management Program director. Members include energy and sustainability managers from federal agencies.

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Energy manager design for microgrids  

SciTech Connect (OSTI)

On-site energy production, known as distributed energy resources (DER), offers consumers many benefits, such as bill savings and predictability, improved system efficiency, improved reliability, control over power quality, and in many cases, greener electricity. Additionally, DER systems can benefit electric utilities by reducing congestion on the grid, reducing the need for new generation and transmission capacity, and offering ancillary services such as voltage support and emergency demand response. Local aggregations of distributed energy resources (DER) that may include active control of on-site end-use energy devices can be called microgrids. Microgrids require control to ensure safe operation and to make dispatch decisions that achieve system objectives such as cost minimization, reliability, efficiency and emissions requirements, while abiding by system constraints and regulatory rules. This control is performed by an energy manager (EM). Preferably, an EM will achieve operation reasonably close to the attainable optimum, it will do this by means robust to deviations from expected conditions, and it will not itself incur insupportable capital or operation and maintenance costs. Also, microgrids can include supervision over end-uses, such as curtailing or rescheduling certain loads. By viewing a unified microgrid as a system of supply and demand, rather than simply a system of on-site generation devices, the benefits of integrated supply and demand control can be exploited, such as economic savings and improved system energy efficiency.

Firestone, Ryan; Marnay, Chris

2005-01-01T23:59:59.000Z

22

Oklahoma Industrial Energy Management Program  

E-Print Network [OSTI]

The need for sound energy management is no longer worthy of debate. Action is necessary and much is being done by U.S. industry. Unfortunately, however, the majority of the work is being done by the few large energy intensive industries throughout...

Turner, W. C.; Webb, R. E.; Phillips, J. M.; Viljoen, T. A.

1979-01-01T23:59:59.000Z

23

Oklahoma Industrial Energy Management Program  

E-Print Network [OSTI]

In Oklahoma, industry consumes about 35% of the total energy consumed. While it is true that much work has been done in the larger companies, most small to medium sized companies have yet to undertake a substantial energy management program. Often...

Turner, W. C.; Estes, C. B.

1982-01-01T23:59:59.000Z

24

Temporal variability of uranium concentrations and 234 activity ratios in the Mississippi river and its tributaries  

E-Print Network [OSTI]

Temporal variability of uranium concentrations and 234 U/238 U activity ratios in the Mississippi Department of Geology and Geophysics, Texas A&M University, College Station, TX 77845, United States c/238 U activity ratios and total dissolved uranium concentrations in the Lower Mississippi River at New

25

Programs of the Governor's Energy Management Center  

E-Print Network [OSTI]

The 70th Texas Legislature transferred the Energy Efficiency Division of the Public Utility Commission to the Governor's Office in September 1987 and directed the Governor's Energy Management Center (GEMC) to perform energy management services...

Verdict, M.

1988-01-01T23:59:59.000Z

26

Establishing and Maintaining Effective Energy Management Practices  

E-Print Network [OSTI]

SAIC has developed, and has delivered over the past 4 years, training and tools to industry for them to implement energy management practices. Practical Energy Management (PEM) has been delivered to over 1000 industry professionals, arming them...

Giffin, T. M.

2008-01-01T23:59:59.000Z

27

BASF Corporate Energy Management Process  

E-Print Network [OSTI]

Process 2 2 ? Brief introduction to BASF ? BASF Corporate Energy Management ? Management Support ? Goals ? Continuous Improvement ? Knowledge Sharing ? Recognition ESL-IE-14-05-30 Proceedings of the Thrity-Sixth Industrial Energy Technology Conference... • 2013 Sales: €74 Billion • Employees: 112,000 Company overview BASF – The Chemical Company 3 ESL-IE-14-05-30 Proceedings of the Thrity-Sixth Industrial Energy Technology Conference New Orleans, LA. May 20-23, 2014 Structure of BASF’s segments...

Geiger, T.

2014-01-01T23:59:59.000Z

28

Energy Management Programs- Monitoring Performance  

E-Print Network [OSTI]

ENERGY MANAGEMENT PROGRAMS - MONITORING PERFORMANCE Stanley P. Pauls Mustafa D. Shamy Merck & Co., Inc. Rahway, N. J. ABSTRACT of the historical energy consumption records. Energy use standards have been established to Steam Model monitor... energy conservation performance in bulk pharmaceutical plants. The model considers The basic steam model for most industrial process, comfort heating, and fixed loads. operations is made up of the following components: As the oil crisis developed...

Pauls, S. P.; Shamy, M. D.

29

Successes in School Energy Management  

E-Print Network [OSTI]

- Master Plan ? Knows where the energy is going ? Benchmarking - Smart Metering ? Refines operations to match current needs ? M&O - RetroCommissioning - Behavioral ? Never stops looking for ways to improve ? Continuous Auditing...CATEE 2012 ?Successes in School Energy Management? Jim Brown, P.E. Principal ? Facilities Division Regional Manager 512-258-0547 jwbrown@terracon.com The Successful Energy Department ---- ? Always has a PLAN ? Energy Policy - Energy Plan...

Brown, J.

2012-01-01T23:59:59.000Z

30

Federal Energy Management Program (FEMP) Technical Assistance...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

(FEMP) Technical Assistance Request Portal User Guide Federal Energy Management Program (FEMP) Technical Assistance Request Portal User Guide Document explains how to navigate the...

31

Lead by Example with Smart Energy Management  

SciTech Connect (OSTI)

The Lead by Example with Smart Energy Management brochure describes FEMP's services, namely financing and acquisition support, technical assistance and policy, and outreach and coordination.

Not Available

2006-07-01T23:59:59.000Z

32

Energy management handbook. Second edition  

SciTech Connect (OSTI)

Separate abstracts were prepared for 25 chapters of this book. Written by a team of professionals in response to steadily accelerating energy costs, this fact-packed guide is designed as a practical, stand alone reference for those responsible for managing energy costs. The second edition has been completely updated, and is published in an expanded format for easier reference. In it is all the data and information needed to design and implement a successful energy management program for businesses, commercial buildings and industrial plants. By applying the simple principles and techniques contained in the handbook, it is possible to realize a cost savings of 15-30% and some companies have achieved as much as 60% savings.

Turner, W.C.

1993-01-01T23:59:59.000Z

33

The Part-time MBA Energy Management Our MBA Energy Management Mission  

E-Print Network [OSTI]

The Part-time MBA Energy Management Our MBA Energy Management Mission To deliver high quality, energy industry focussed, graduate management education that prepares individuals for their future Management for? The part-time MBA Energy Management programme at the Graduate Business School is designed

Levi, Ran

34

Synthesised Constraint Models for Distributed Energy Management  

E-Print Network [OSTI]

generation [1], demand-side manage- ment, or building control software. In a producer-based view, supplySynthesised Constraint Models for Distributed Energy Management Alexander Schiendorfer, Jan frequently encountered in energy management systems such as the coordination of power generators in a virtual

Reif, Wolfgang

35

Strategic Energy Management Plan for the 1990's  

E-Print Network [OSTI]

This paper describes the strategic energy management plan implemented by the Defense Systems and Electronics Group (DSEG) of Texas Instruments (TI) to enable it to meet its energy management challenge into the 1990's. The strategic energy management...

Fiorino, D. P.; Priest, J. W.

1987-01-01T23:59:59.000Z

36

FEMP (Federal Energy Management Program) Update, Spring 1989  

SciTech Connect (OSTI)

The FEMP Update, published quarterly by the Federal Energy Management Program (FEMP), provides information that will assist federal managers in their energy management responsibilities. The Update is distributed primarily to federal facility and energy management personnel.

Not Available

1989-04-01T23:59:59.000Z

37

System design and dynamic signature identification for intelligent energy management in residential buildings.  

E-Print Network [OSTI]

for Intelligent Energy Management in Residential Buildingsfor Intelligent Energy Management in Residential Buildingsthat can provide autonomous energy management to residential

Jang, Jaehwi

2008-01-01T23:59:59.000Z

38

Functional Facilities Management Energy Management Structure  

E-Print Network [OSTI]

Functional Facilities Management Energy Management Structure Jerome Malmquist Director Erick Van Controls Systems Jeff Davis Assistant Director, Facilities Engineering & Energy Efficiency Gene Husted Principal Engineer / Commissioning Emily Robin-Abbott St. Paul Energy Engineer & Technicians Supervisor Dan

Gulliver, Robert

39

Deere and Company Energy Management Program  

E-Print Network [OSTI]

An overview of the Deere & Company energy management program is discussed. A review is made of seven key elements which have contributed to the success of the program. Installed projects and established programs are identified and discussed...

Boyd, P. M.

1980-01-01T23:59:59.000Z

40

Predictive Technology Development and Crash Energy Management...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Annual Merit Review and Peer Evaluation Meeting, May 18-22, 2009 -- Washington D.C. lm09kia.pdf More Documents & Publications ACC100 Crash Energy Management Advanced...

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

General Purpose Microcomputers in Energy Management  

E-Print Network [OSTI]

these may be implemented in energy management. A project at the University of Texas at Austin to develop a package of energy conservation software is described, and examples are given of other commercially available software suitable for energy conservation...

Schmidt, P. S.

1981-01-01T23:59:59.000Z

42

Total Energy Management in General Motors  

E-Print Network [OSTI]

This paper presents an overview of General Motors' energy management program with special emphasis on energy conservation. Included is a description of the total program organization, plant guidelines, communication and motivation techniques...

DeKoker, N.

1979-01-01T23:59:59.000Z

43

Energy Management: A Corporate Objective in the Five-Year Business Plan  

E-Print Network [OSTI]

This paper presents the Energy Management Program developed by the Western Electric Company. The program includes managerial accountabilities; administrative and technical activities; and a most recently implemented comprehensive five-year energy...

Mulhern, T. A.

1982-01-01T23:59:59.000Z

44

Automated Home Energy Management (AHEM) Standing Technical Committee...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Home Energy Management (AHEM) Standing Technical Committee Strategic Plan - February 2012 Automated Home Energy Management (AHEM) Standing Technical Committee Strategic Plan -...

45

Facility Energy Management Guidelines and Criteria for Energy...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities Facility Energy Management Guidelines and Criteria for Energy and Water...

46

Better Buildings Workforce Guidelines for Facility Energy Manager...  

Energy Savers [EERE]

Guidelines for Facility Energy Manager - 2014 BTO Peer Review Better Buildings Workforce Guidelines for Facility Energy Manager - 2014 BTO Peer Review Presenter: Phil Coleman,...

47

Energy Management Systems Package for Small Commercial Buildings...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Energy Management Systems Package for Small Commercial Buildings Energy Management Systems Package for Small Commercial Buildings Commercial Buildings Integration Project for the...

48

Successes in School Energy Management - Energy Monitoring  

E-Print Network [OSTI]

Successes in School Energy Management ? Energy Monitoring Chad Corbitt, CEM, ATEM Energy Manager, Klein ISD jcorbitt1@kleinisd.net Wednesday, October 10, 2012 Keys to Energy Monitoring ? Develop an Energy Monitoring plan ? Define... the why, what, how and who of the plan ? Implement the Energy Monitoring plan ? Personnel, data system, reporting ? One Experience in Energy Monitoring Developing an Energy Monitoring Plan ? Why do we need to monitor energy? ? What information...

Corbitt, C.

2012-01-01T23:59:59.000Z

49

Real-Time Demand Side Energy Management  

E-Print Network [OSTI]

Real-Time Demand Side Energy Management Annelize Victor Michael Brodkorb Sr. Business Consultant Business Development Manager Aspen Technology, Inc. Aspen Technology España, S.A. Houston, TX Barcelona, Spain ABSTRACT To remain... competitive, manufacturers must capture opportunities to increase bottom-line profitability. The goal of this paper is to present a new methodology for reducing energy costs – “Demand-Side Energy Management.” Learn how process manufacturers assess energy...

Victor, A.; Brodkorb, M.

2006-01-01T23:59:59.000Z

50

Energy Management Workbook for Local Governments : Workbook 1, Electrical Energy, 1981.  

SciTech Connect (OSTI)

Descriptions are presented for 20 major categories of energy actions providing background information needed for communities to implement energy management programs and explaining where financial and technical help may be available. Chapter 1 provides background on the energy problem, discusses Federal, state and local roles, and outlines the planning process. Chapter 2 is a list of 20 questions to help identify a range of potential actions that could become part of the energy management plan. Chapter 3 will help evaluate each of the twenty potential activities, and chapters 4 and 5 discuss implementing and monitoring the energy management plan. (MCW)

None

1981-02-01T23:59:59.000Z

51

Seamless Energy Management Systems Part I: Assessment of Energy  

E-Print Network [OSTI]

Seamless Energy Management Systems Part I: Assessment of Energy Management Systems and Key to Engineer the Future Electric Energy System #12;#12;Seamless Energy Management Systems Part I: Assessment of Energy Management Systems and Key Technological Requirements Final Project Report Project Faculty Team

52

Energy Management Practices at Dalls/Fort Worth International Airport  

E-Print Network [OSTI]

Energy Management Practices at Dallas/Fort Worth International Airport Jerry R. Dennis, CEM, CEP Energy Manager October 9, 2013 Energy Management Practices at DFW Airport, October 9, 2013 Presentation Outline ? DFW Airport Overview ? Energy... Management Section ? Structure & Mission ? Supply-Side Management ? Reliability ? Cost (Risk) mitigation ? Environmental stewardship ? Demand-Side Management ? Energy monitoring ? Energy audits ? Energy standards ? Continuous Commissioning...

Dennis, J. R.

2013-01-01T23:59:59.000Z

53

Discrimination of nuclear explosions against civilian sources based on atmospheric xenon isotopic activity ratios  

SciTech Connect (OSTI)

A global monitoring system for atmospheric xenon radioactivity is being established as part of the International Monitoring System that will be used to verify compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT) once the treaty has entered into force. This paper studies isotopic activity ratios to support interpretation of observed atmospheric concentrations of 135Xe, 133mXe, 133Xe and 131mXe. The goal is to distinguish nuclear explosion sources from civilian releases. Simulations of nuclear explosions, empirical data for both test and reactor releases as well as observations by measurement stations of the International Noble Gas Experiment (INGE) are used to provide a proof of concept for the isotopic ratio based method for source discrimination.

Kalinowski, Martin B.; Axelssson, A.; Bean, Marc; Blanchard, X.; Bowyer, Ted W.; Brachet, G.; McIntyre, Justin I.; Peters, Jana; Pistner, Christoph; Raith, Maria; Ringbom, Anders; Saey, P. R.; Schlosser, C.; Stocki, Trevor J.; Taffary, T.; Ungar, R. Kurt

2010-05-01T23:59:59.000Z

54

EPRI's Industrial Energy Management Program  

E-Print Network [OSTI]

the Electric Power Research Institute has been establishing industry specific Centers and Offices nationwide to assist electric utilities and their customers in managing for a better use of energy. Hundreds of joint industry/utility projects... services thus supporting national objectives for a clean environment and a strong economic future. The Electric Power Research Institute (EPRI) recognizes that the management of energy use and the environmental impacts of industrial activity...

Mergens, E.; Niday, L.

55

Oklahoma Industrial Energy Management Program  

E-Print Network [OSTI]

fact she~t was i initiated las a ! 5. Recognizes outstanding activities or contributions Consequently, the terms technology, and equipmeqt are One of the problems encountered is that ene~gy management technology is not very mature (in gen~ral). i...~ , being developed includes: i 1. A solar collector connected'to a coffee pot tio produce hot water for instant coffee. 2. A solar photovoltaic converter used to deli~er power to a child's toy. 3. Two power factor experiments designed to shoW what...

Estes, C. B.; Turner, W. C.

1980-01-01T23:59:59.000Z

56

Performance Auditing of Energy Management Programs  

E-Print Network [OSTI]

With the oil crisis of the 1970's, energy management programs became important to both the private and public sectors. But with the decrease of oil prices in the mid 1980's, interest in energy conservation programs has declined. Nevertheless, energy...

White, J. A.

1988-01-01T23:59:59.000Z

57

The Next Generation Energy Management System Design  

E-Print Network [OSTI]

Paul Myrda, EPRI Naim Logic SRP George Stefopoulos, NYPA Michael Swider, New York ISO. i #12;iiThe Next Generation Energy Management System Design Final Project Report Power Systems Engineering Research Center Empowering Minds to Engineer the Future Electric Energy System #12;#12;The Next Generation

58

PV Integration by Building Energy Management System  

E-Print Network [OSTI]

. However, to validate global control algorithms, a simulator capable of interoperating with energy[kWh]. Econs (k) Total energy consumed by the load [kWh]. E (i, k) Energy consumed by the service i duringPV Integration by Building Energy Management System Rim.Missaoui¹, Ghaith.Warkozek¹, Seddik. Bacha

Boyer, Edmond

59

Use of plutonium isotope activity ratios in dating recent sediments. [/sup 238/Pu//sup 239/Pu + /sup 240/Pu  

SciTech Connect (OSTI)

The majority of plutonium presently in the biosphere has come from the testing of nuclear devices. In the early 1950s, the Pu-238/239+240 activity ratio of fallout debris was > 0.04; in the more extensive test series of 1961 to 1962, the Pu-238/239+240 activity ratios were quite consistent at 0.02 to 0.03 and maximum fallout delivery occurred in mid-1963. A significant perturbation in Pu isotope activity ratios occurred in mid-1966 with the deposition of Pu-238 from the SNAP-9A reentry and burn-up. Recently deposited sediments have recorded these events and where accumulation rates are rapid (> 1 cm/y), changes in Pu isotope activity ratios can be used as a geochronological tool.

Beasley, T. M.

1982-01-01T23:59:59.000Z

60

Implementing an Energy Management Strategy for a Houston Refinery  

E-Print Network [OSTI]

and maintained energy management program translates to PROFIT added directly to the BOTTOM LINE. Woodward-Clyde Consultants (WCC) recently implemented and energy management program at the Lyondell-Citgo Refinery in Houston, Texas. The basis of the program...

Wood, S. C.; Agrawal, R. K.; Canon, D.

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Energy Management - What Is Its Role in 1984?  

E-Print Network [OSTI]

This paper explores the situation, as industry enters 1984, of energy management and the energy manager as compared to the 1973-83 period. It examines the trend toward local management responsibility for energy and appropriate goals in energy...

Hogeland, A. W.

1984-01-01T23:59:59.000Z

62

Facilitating Sound, Cost-Effective Federal Energy Management (Fact Sheet)  

SciTech Connect (OSTI)

This fact sheet is an overview of the U.S. Department of Energy's Federal Energy Management Program (FEMP).

Not Available

2012-12-01T23:59:59.000Z

63

Federal Energy Management Program Procedure for Notifying Congress...  

Broader source: Energy.gov (indexed) [DOE]

Document displays the Federal Energy Management Program's Procedure for notifying Congress prior to awarding energy savings performance contracts (ESPCs) espccongressionalnotific...

64

Data-Driven, Strategic Energy Management | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Building Energy Use Benchmarking Benchmarking & Disclosure Policy Data-Driven, Strategic Energy Management Data Access Evaluation, Measurement, & Verification Energy Technologies...

65

Driving Energy Performance with Energy Management Teams  

E-Print Network [OSTI]

Driving Energy Performance with Energy Management Teams Meredith Younghein ENERGY STAR Industrial Communications Mgr. U.S. Environmental Protection Agency Washington, DC ABSTRACT Companies today face an uncertain energy future. Businesses... face escalating energy prices which can erode profits. Concerns over supply reliability, and possible regulation of carbon emissions create risk. For many industries in the U.S., energy costs are equal to the cost of raw materials or even employee...

Younghein, M.; Tunnessen, W.

2006-01-01T23:59:59.000Z

66

Industrial Energy Management: Doing More with Less  

E-Print Network [OSTI]

during the course of business — with energy-intensive operations such as aluminum and chemical processing plants experiencing energy costs between five and 10 times higher than industry averages (Source: Department of Energy, Office of Industrial... INDUSTRIAL ENERGY MANAGEMENT: DOING MORE WITH LESS Jason Sheppard, Industrial Market Segment Manager Anthony Tisot, Communications Manager Power Monitoring and Control SCHNEIDER ELECTRIC Victoria, BC, Canada ABSTRACT The cost of doing...

Sheppard, J.; Tisot, A.

2006-01-01T23:59:59.000Z

67

Federal Energy Management Program Report Template  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPCofConstructionofFYOxideof1 DOEFederal Energy Management

68

Integrating Concurrency Control and Energy Management in Device Drivers  

E-Print Network [OSTI]

Integrating Concurrency Control and Energy Management in Device Drivers Kevin Klues , Vlado@cs.berkeley.edu dgay@intel-research.net Abstract Energy management is a critical concern in wireless sensornets. De- spite its importance, sensor network operating systems today pro- vide minimal energy management support

Levis, Philip

69

Seamless Energy Management Systems Part II: Development of Prototype  

E-Print Network [OSTI]

Seamless Energy Management Systems Part II: Development of Prototype Core Elements Final Project System #12;#12;Seamless Energy Management Systems Part II: Development of Prototype Core Elements Final Center (PSERC) research project entitled "Seamless Energy Management Systems" (S-53G for 2013

70

Examining Synergies between Energy Management and Demand Response: A  

E-Print Network [OSTI]

LBNL-5719E Examining Synergies between Energy Management and Demand Response: A Case Study at Two Summary #12;Introduction Energy Management · · · · · · · · · · #12;Demand Response #12;#12;Bentley Prince-Project Personnel Changes #12;Enablement of Demand Response Capabilities due to Energy Management Improvement

71

A MINIMAL MODEL OF ENERGY MANAGEMENT IN THE BRAIN  

E-Print Network [OSTI]

a minimal model of energy management inside a single cortical area, featuring local energy storage a simple model for energy man- agement within a single cortical area. By energy management, we mean a setA MINIMAL MODEL OF ENERGY MANAGEMENT IN THE BRAIN Florian A. Dehmelt, Christian K. Machens Group

Paris-Sud XI, Université de

72

Thinking Globally: How ISO 50001 - Energy Management can make industrial energy efficiency standard practice  

E-Print Network [OSTI]

The purpose of an energy management system standard is towww.iso.org/iso/energy_management_system_standard Relatedof an energy management system. For organizations already

McKane, Aimee

2010-01-01T23:59:59.000Z

73

Examining Synergies between Energy Management and Demand Response: A Case Study at Two California Industrial Facilities  

E-Print Network [OSTI]

Capabilities due to Energy Management Improvement inSummary Introduction Energy Management Demand Responseand Processes Energy Management and Demand Response History

Olsen, Daniel

2013-01-01T23:59:59.000Z

74

Collecting Occupant Presence Data for Use in Energy Management of Commercial Buildings  

E-Print Network [OSTI]

of fit between each energy management strategy and eachWayne Turner. 2009. Energy management handbook. 7th ed. TheData Needed for Energy Management Strategies .23

Rosenblum, Benjamin Tarr

2012-01-01T23:59:59.000Z

75

Thinking Globally: How ISO 50001 - Energy Management can make industrial energy efficiency standard practice  

E-Print Network [OSTI]

Comparison of National Energy Management Standards, prepared2007, Industrial Energy Management: Issues Paper, preparedMeeting: Using Energy Management Standards to stimulate

McKane, Aimee

2010-01-01T23:59:59.000Z

76

Occupancy-Based Energy Management in Buildings: Final Report to Sponsors  

E-Print Network [OSTI]

2009. Payne FW. Energy management control system handbook.5] F. W. Payne. Energy management control system hand- book.Occupancy- Based Energy Management Systems for Buildings:

Sohn, Michael D.

2010-01-01T23:59:59.000Z

77

E-Print Network 3.0 - activity ratio disequilibrium Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the oxida- tive ratio of the return flux (Rba). After a period of ... Source: Randerson, James T. - Department of Earth System Science, University of California, Irvine...

78

Conservation - The Keystone of Energy Management  

E-Print Network [OSTI]

THESE TECHNIQUES. INTRODUCTION THANK YOU FOR AFFORDING ME THE OPPORTUNITY TO PRESENT THE IH ENERGY MANAGEMENT PRO GRA~,.:. I BELIEVE IT IS THROUGH THIS TYPE OF FREE AND OPEN EXCHANGE THAT THE CAUSE OF ENERG Y MANAGEMENT IS MOST EFFICIENTLY ADVANCED... IN OURS. THE IH PROGRAt-.l INCLUDES: - SUPPORT OF TOP l\\llANAGEMENT DEFI1'iITE GOAL - PLANT SPECIFIC PLAN - PLANT ENERG Y COORDINATOR - $16 MILLION BUDGET NO PROGRAM CAN BE SUCCESSFUL IF NOT SUP PORTED BY THE BOSS. A PROGRAM WITHOUT A GOAL...

Read, R. C.

1981-01-01T23:59:59.000Z

79

Federal Energy Management Program Report Template  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPCofConstructionofFYOxideof1 DOEFederal Energy ManagementPV

80

Federal Energy Management Program: BLCC5 Registration  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPCofConstructionofFYOxideof1 DOEFederal Energy ManagementPVFederal

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Federal Energy Management Program | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA5 &ofDepartment of EnergyEnergy Management Program August

82

Energy Management Standards (EnMS)  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE:2009 DOEDeploymentHenry C. FoleyEnergy Management

83

The structure of energy management systems  

SciTech Connect (OSTI)

Energy management systems (EMS) which serve a variety of building functions are a complex combination of hardware and software. The design of the system is a trade-off between different characteristics including functions performed, number of connected points, cost, compatibility with other systems, reliability and flexibility. The functions performed by the EMS vary significantly with respect to complexity, interaction and rate of response required. The majority of functions interact either directly or indirectly with each other. The data required to support EMS functions can be classed as status, control, qualifying and informational. The amount of data required is extensive and must be brought together in many combinations to achieve the desired performance. The transfer of data is carried out by a communication system which connects the components of the EMS. The communication requirements, in addition to functional performance, are influenced by the application flexibility desired and the level of distribution of the system. Three general distribution levels are centralized, status and control decentralized, and functionally decentralized. The ability of the EMS of one manufacturer to interact effectively with EMS components or complete systems of other manufacturers is limited by the respective selections for data structures, communication methods and level of distribution. In general, the unique selection of characteristics chosen by each manufacturer precludes the integration of energy management system components of different manufacturers unless details of implementation are known.

Miller, D.E.

1983-06-01T23:59:59.000Z

84

Harrison Radiator Division's Energy Management, Reporting and Accounting System  

E-Print Network [OSTI]

HARRISON RADIATOR DIVISION'S ENERGY MANAGEMENT, REPORTING and ACCOUNTING SYSTEM Ronald J. Goubeaux Harrison Radiator Division Lockport, New York ABSTRACT Energy management is essential for obtaining the lowest possible product..., farm equipment, small aircraft and other types of vehicles. The energy management, reporting and accounting system that is covered in this paper is operating in Harrison's West Complex of the New York Operations located in Lockport, Western...

Goubeaux, R. J.

85

2008 Federal Energy Management Program (FEMP) Market Report  

SciTech Connect (OSTI)

This report assesses the market for Federal Energy Management Program (FEMP) services as it existed in FY 2008. It discusses Federal energy management goal progress in FY 2008, and examines the environment in which agencies implemented energy management projects over the last three years. The report also discusses some recent events that will increase the market for FEMP services, and outlines FEMP's major strategies to address these changes in FY 2009 and beyond.

Tremper, C.

2009-07-01T23:59:59.000Z

86

Ocean Energy Technology Overview: Federal Energy Management Program (FEMP)  

SciTech Connect (OSTI)

Introduction to and overview of ocean renewable energy resources and technologies prepared for the U.S. Department of Energy Federal Energy management Program.

Not Available

2009-07-01T23:59:59.000Z

87

Anaheim Public Utilities- Small Business Energy Management Assistance Program  

Broader source: Energy.gov [DOE]

The Small Business Energy Management System Program provides participating customers with free electrical energy use evaluations, retrofit funding, and installation assistance. Anaheim Public...

88

Energy Management Strategies for Fast Battery Temperature Rise...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Very Cold Conditions Energy Management Strategies for Fast Battery Temperature Rise and Engine Efficiency Improvement at Very Cold Conditions 2010 DOE Vehicle Technologies and...

89

proactive energy management for next-generation building systems  

E-Print Network [OSTI]

Mar 3, 2010 ... Abstract: We present a proactive energy management framework that ... capture net-metering interactions using agent-based market models.

Victor M Zavala

2010-03-03T23:59:59.000Z

90

VOLTTRONTM as an Open Source Platform for Energy Management Applicatio...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Virginia Tech VOLTTRON TM as an Open Source Platform for Energy Management Applications HVAC Controllers Lighting Controllers Lighting circuit(s) Plug load Controllers July 23,...

91

Lead by Example with Smart Energy Management FEMP (Revised Brochure)  

SciTech Connect (OSTI)

This brochure provides the primary audience of Federal facility and energy managers with an accurate understanding of the services and assistance available through FEMP.

Not Available

2008-07-01T23:59:59.000Z

92

Save Energy Now Assessment Helps Expand Energy Management Program...  

Broader source: Energy.gov (indexed) [DOE]

identify significant energy savings opportunities in their Dalton, Georgia, plant's steam system. Save Energy Now Assessment Helps Expand Energy Management Program at Shaw...

93

Energy Management and Information Systems Study - 2014 BTO Peer...  

Energy Savers [EERE]

Management and Information Systems Study - 2014 BTO Peer Review Energy Management and Information Systems Study - 2014 BTO Peer Review Presenter: Jessica Granderson, Lawrence...

94

Lighting energy management in industrial plants  

SciTech Connect (OSTI)

This paper provides some guidance to assist plant managers and engineers in managing their light energy problems. Incandescent, flourescent, and high-intensity discharge lamps are compared. Flourescent is still predominant, incandescent is not recommended-and HID is rapidly gaining favor. Lamp life and lumen depreciation must be determined. Light loss factors which are not recoverable are: luminaire ambient temperature, voltage to the luminaire, ballast factor, and luminaire surface dirt depreciation. Light loss factors which can be recovered by plant maintainence are: room surface dirt depreciation, lamp failures, lamp lumen depreciation, and luminaire dirt depreciation. A method to determine the savings that may result from group relamping versus spot replacement is given. Finally, energy management steps, to maximize performance, are listed.

Bachler, J.M.

1982-06-01T23:59:59.000Z

95

Software aspects of energy management systems  

SciTech Connect (OSTI)

This paper is intended to serve the need for an understanding of the role which software plays in energy management systems (EMS), and of the considerations involved in designing, implementing and maintaining such systems. The paper begins with a brief elementary examination of what software is and the types of basic functions it typically performs in EMS applications. Various aspects of EMS software are then explained and discussed, including software architecture, programming language, operating system, data base management, man-machine interface, application software, and communications. In addition to providing a tutorial on the composition and content of EMS software, the paper addresses several related questions, such as the reasons for choosing one programming language over another, the effect of system size on software factors, the extent to which off-the-shelf software components can and should be incorporated in EMS, and the relationship of software to the overall user interface with the systems.

Stinaff, R.D.

1983-06-01T23:59:59.000Z

96

What is Energy Management and why is it important?  

E-Print Network [OSTI]

planning. Energy security, supply, pricing and use, along with environmental impact, are already keyMSc Energy Management #12;What is Energy Management and why is it important? Management of the world's energy supplies has always been vitally important but today, with increasingly complex factors

Little, Tony

97

Smart Sensing, Estimation, and Prediction for Efficient Building Energy Management  

E-Print Network [OSTI]

Smart Sensing, Estimation, and Prediction for Efficient Building Energy Management Sunil Mamidi energy management software can greatly decrease the energy usage of HVAC systems in many building to improve efficiency. In most buildings, the most advanced examples of this type of system are the motion

Chang, Yu-Han

98

ENERGY MANAGEMENT REAL-TIME MULTI-TIER INTERNET SERVICES  

E-Print Network [OSTI]

ENERGY MANAGEMENT IN REAL-TIME MULTI-TIER INTERNET SERVICES A Dissertation Presented to the faculty This dissertation has been read and approved by the examining Committee: Kevin Skadron (Advisor) Sudhanva Gurumurthi and Applied Science: James H. Aylor (Dean) May 2008 #12;Abstract Energy management only recently emerged

Skadron, Kevin

99

The Seven Keys to Success in Energy Management and Conservation  

E-Print Network [OSTI]

This paper is a summary of the seven key elements of the Deere & Company Energy Management and Conservation Program. These elements have been found to be essential for the ultimate success of any company-wide energy management program. The process...

Darby, D. F.

1984-01-01T23:59:59.000Z

100

Predictive energy management for hybrid electric vehicles -Prediction horizon and  

E-Print Network [OSTI]

Predictive energy management for hybrid electric vehicles - Prediction horizon and battery capacity of a combined hybrid electric vehicle. Keywords: Hybrid vehicles, Energy Management, Predictive control, Optimal vehicle studied uses a complex transmission composed of planetary gear sets and two electric motors

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Maximizing Thermal Efficiency and Optimizing Energy Management (Fact Sheet)  

SciTech Connect (OSTI)

Researchers at the Thermal Test Facility (TTF) on the campus of the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) in Golden, Colorado, are addressing maximizing thermal efficiency and optimizing energy management through analysis of efficient heating, ventilating, and air conditioning (HVAC) strategies, automated home energy management (AHEM), and energy storage systems.

Not Available

2012-03-01T23:59:59.000Z

102

Energy management system for a rotary machine and method therefor  

DOE Patents [OSTI]

In energy management system is provided for a power generating device having a working fluid intake in which the energy management system comprises an electrical dissipation device coupled to the power generating device and a dissipation device cooling system configured to direct a portion of a working fluid to the electrical dissipation device so as to provide thermal control to the electrical dissipation device.

Bowman, Michael John; Sinha, Gautam (NMN); Sheldon, Karl Edward

2004-11-09T23:59:59.000Z

103

Trends in Energy Management Technology - Part 4: Review ofAdvanced Applications in Energy Management, Control, and InformationSystems  

SciTech Connect (OSTI)

In this article, the fourth in a series, we provide a review of advanced applications in Energy Management, Control, and Information Systems (EMCIS). The available features for these products are summarized and analyzed with regard to emerging trends in EMCIS and potential benefits to the Federal sector. The first article [1] covered enabling technologies for emerging energy management systems. The second article [2] serves as a basic reference for building control system (BCS) networking fundamentals and includes an assessment of current approaches to open communications. The third article [3] evaluated several products that exemplify the current state of practice in EMCIS. It is important for energy managers in the Federal sector to have a high level of knowledge and understanding of these complex energy management systems. This series of articles provides energy practitioners with some basic informational and educational tools to help make decisions relative to energy management systems design, specification, procurement, and energy savings potential.

Yee, Gaymond; Webster, Tom

2003-08-01T23:59:59.000Z

104

Annual report to Congress on Federal Government Energy Management and Conservation Programs  

SciTech Connect (OSTI)

This report on Federal Energy Management for Fiscal year (FY) 1992 provides information on energy consumption in Federal buildings and operations and documents activities conducted by Federal agencies to meet the statutory requirements of Title V, Part 3, of the National Energy Conservation Policy Act (NECPA), as amended, 42 U.S.C. 8251-8261, and Title VIII of NECPA, 42 U.S.C. 8287-8287b. This report also describes the energy conservation and management activities of the Federal Government under the authorization of section 381 of the Energy Policy and Conservation Act (EPCA), as amended, 42 U.S.C. 6361. Implementation activities undertaken during FY 1992 by the Federal agencies under Executive Order 12759 on Federal Energy Management are also described in this report.

Not Available

1994-02-01T23:59:59.000Z

105

Facilitating Sound, Cost-Effective Federal Energy Management (Fact Sheet)  

SciTech Connect (OSTI)

This fact sheet is an overview of the U.S. Department of Energy's Federal Energy Management Program (FEMP). The Federal Government, as the nation's largest energy consumer, has a tremendous opportunity and acknowledged responsibility to lead by example. The U.S. Department of Energy's (DOE's) Federal Energy Management Program (FEMP) plays a critical role in this effort. FEMP facilitates the Federal Government's implementation of sound, cost-effective energy management and investment practices to enhance the nation's energy security and environmental stewardship. FEMP does this by focusing on the needs of its Federal customers, delivering an array of services across a variety of program areas.

Not Available

2012-03-01T23:59:59.000Z

106

Multi-mode Energy Management for Multi-tier Server Tibor Horvath  

E-Print Network [OSTI]

Multi-mode Energy Management for Multi-tier Server Clusters Tibor Horvath tibor Charlottesville, VA 22904 ABSTRACT This paper presents an energy management policy for recon- figurable clusters General Terms Algorithms, Design, Experimentation, Management, Perfor- mance Keywords energy management

Skadron, Kevin

107

Development of an International Standard for Energy Management  

E-Print Network [OSTI]

International interest in energy management is driving the development of an ISO management standard. The U.S. DOE is leading this effort in partnership with other countries. The speakers will describe the development of an international management...

Meffert, B.; McKane, A.

108

The Role of Benchmarking in Promoting Strong Energy Management Systems  

E-Print Network [OSTI]

The significance of formalized energy management practices and programs in driving and sustaining energy efficiency improvements within the industrial sector has become more widely recognized over the past several years. The release of the ISO 50001...

Tunnessen, W.

2010-01-01T23:59:59.000Z

109

Driving Water and Wastewater Utilities to More Sustainable Energy Management  

E-Print Network [OSTI]

The Water Environment Federation (WEF) and industry leaders have identified the need for an energy roadmap to guide utilities of all sizes down the road to sustainable energy management through increased renewable energy production, energy...

Ferrel, L.; Liner, B.

2013-01-01T23:59:59.000Z

110

Process and Energy Optimization Revitalizes Energy Management at Eastman  

E-Print Network [OSTI]

In 2005, the Eastman-Texas Operations Energy Management Team (EMT), in response to rapidly increasing energy prices, initiated a new energy optimization program to optimize the site’s energy intensity. This new program utilized a process and energy...

Greenwaldt, W. C.

2007-01-01T23:59:59.000Z

111

Ph.D. Positions in "ICT for Sustainable Energy Management"  

E-Print Network [OSTI]

Ph.D. Positions in "ICT for Sustainable Energy Management" Key words: distributed information systems, smart grids, renewable energy, energy efficiency, energy storage, power systems, green computing's main research areas will be Information and Communication Technology (ICT) for sustainable energy

Teschner, Matthias

112

Automated Home Energy Management Standing Technical Committee Presentation  

Broader source: Energy.gov [DOE]

This presentation outlines the goals of the Automated Home Energy Management Standing Technical Committee, as presented at the Building America Spring 2012 Stakeholder meeting on February 29, 2012, in Austin, Texas.

113

Corporate Energy Management: A Survey of Large Manufacturing Companies  

E-Print Network [OSTI]

Corporate practices regarding energy management vary substantially from one company to another. Some companies pay close attention to energy use throughout the corporation while others pay scant attention. This paper first describes what we call...

Norland, D. L.; Lind, L.

114

The Department of Homeland Security Energy Management Program  

Energy Savers [EERE]

Security Energy Management Program May 2, 2007 DHS Energy Program Overview Steven W. White, CEM May 2, 2007 2 Policy "It is the policy of the United States that Federal agencies...

115

Contract Management Using Industrial Energy Management & Reporting Systems  

E-Print Network [OSTI]

Energy Management and Reporting Systems (EMRS) are rule-based control systems with a record of reducing energy usage and CO2e emissions while optimizing electrical generation in a real time environment. The rule set successfully optimizes energy...

Robinson, J. E.

2011-01-01T23:59:59.000Z

116

Energy Management Degree Specialization at Texas A&M University  

E-Print Network [OSTI]

. The internship program allows students to receive valuable on-the-job experience while providing industries with trained engineers to assist in solving specific problems. The overall objective of the energy management program is to train industrial energy...

Murphy, W. E.; O'Neal, D. L.; Heffington, W. M.; Turner, W. D.; Somasundaram, S.; Holmes, R. E.

117

Training for Energy Management : Experience in One State  

E-Print Network [OSTI]

This paper examines the need for energy management education in the industrial sector, and focuses on the cooperative efforts of federal and state governments and educational organizations/institutions to fulfill that need. The roles of government...

Jacobs, I. M.

1980-01-01T23:59:59.000Z

118

Demand Control Utilizing Energy Management Systems - Report of Field Tests  

E-Print Network [OSTI]

Energy Management systems and particularly demand controllers are becoming more popular as commercial and light industrial operations attempt to reduce their electrical usage and demand. Numerous techniques are used to control energy use and demand...

Russell, B. D.; Heller, R. P.; Perry, L. W.

1984-01-01T23:59:59.000Z

119

Peer Review of the Federal Energy Management Program Energy-Efficient...  

Broader source: Energy.gov (indexed) [DOE]

Peer Review of the Federal Energy Management Program Energy-Efficient Product Procurement Portfolio Peer Review of the Federal Energy Management Program Energy-Efficient Product...

120

Thinking Globally: How ISO 50001 - Energy Management can make industrial energy efficiency standard practice  

E-Print Network [OSTI]

Thinking Globally: How ISO 50001 – Energy Management canThinking Globally: How ISO 50001 – Energy Management canOrganization for Standardization (ISO) has identified energy

McKane, Aimee

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Leading by Example with Smart Energy Management (Fact Sheet)  

SciTech Connect (OSTI)

The Federal Energy Management Program facilitates the Federal Government?s implementation of sound, cost-effective energy management and investment practices to enhance the nation?s energy security and environmental stewardship. FEMP does this by focusing on the needs of its Federal customers, delivering an array of products grouped into project transaction services, applied technology services, and decision support services. This document outlines FEMP services and programs.

Not Available

2008-12-01T23:59:59.000Z

122

Using Energy Management Control Systems for HVAC Operational Diagnostics  

E-Print Network [OSTI]

USING ENERGY MANAGEMENT CONTROL SYSTEMS FOR HVAC OPERATIONAL DIAGNOSTICS Karl Stum, P.E. Portland Energy Conservation, Inc. 92 1 SW Washington, Suite 3 12 Portland, OR 97205 503-248-4636 Fax 503-295-0820 ABSTRACT The power and flexibility... Proceedings, June 1997. Meyers, S.; E. Mills; A. Chen; L. Demsetz "Building Data Visualization for Diagnostics," ASHRAE Journal, June 1996. PECl (Portland Energy Conservation, Inc.). Energy Management C0ntrof Systems-A Practical Guiak, 1997. Sparks, R...

Stum, K.

1998-01-01T23:59:59.000Z

123

Department of Energy Management of Cultural Resources  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The purpose of this Policy is to ensure that Department of Energy (DOE) programs, including the National Nuclear Security Administration (NNSA), and field elements integrate cultural resources management into their missions and activities. Certified 1-28-11. No cancellation.

2001-05-02T23:59:59.000Z

124

Blazing the energy trail: The Municipal Energy Management Program  

SciTech Connect (OSTI)

The Urban Consortium Energy Task Force pioneers energy and environmental solutions for US cities and counties. When local officials participate in the task force, they open the door to many resources for their communities. The US is entering a period of renewed interest in energy management. Improvements in municipal energy management allow communities to free up energy operating funds to meet other needs. These improvements can even keep energy dollars in the community through the purchase of services and products used to save energy. With this idea in mind, the US Department of Energy Municipal Energy Management Program has funded more than 250 projects that demonstrate innovative energy technologies and management tools in cities and counties through the Urban Consortium Energy Task Force (UCETF). UCETF helps the US Department of Energy foster municipal energy management through networks with cities and urbanized counties and through links with three national associations of local governments. UCETF provides funding for projects that demonstrate innovative and realistic technologies, strategies, and methods that help urban America become more energy efficient and environmentally responsible. The task force provides technical support to local jurisdictions selected for projects. UCETF also shares information about successful energy management projects with cities and counties throughout the country via technical reports and project papers. The descriptions included here capsulize a sample of UCETF`s demonstration projects around the country.

Not Available

1994-12-01T23:59:59.000Z

125

FEMP Update: Federal Energy Management activities, July 1985  

SciTech Connect (OSTI)

Since early 1984, FEMP has examined a number of innovative techniques for financing energy efficiency improvements in Federal facilities. Having identified a number of legal and procurement barriers to shared savings contracting by Federal agencies, FEMP set out to identify and explore possible solutions. Currently, it has narrowed in on three specific options which represent potentially viable approaches to Federal energy financing: (1) removing regulatory and institutional barriers to energy services contracts with the private sector; (2) implementing energy services agreements at Government Owned Contractor Operated (GOCO) facilities; and (3) establishing a government financial corporation to fund agency energy conservation investments. These possible solutions are discussed in the report. The third possibility is regarded as unlikely.

Not Available

1985-01-01T23:59:59.000Z

126

DOE's New Checklist Helps Plants Assess Energy Management Activities |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: TopEnergy DOE Theory Focus SessionDepartment of Energy Technical Assistance

127

Intelligent energy management agent for a parallel hybrid vehicle  

E-Print Network [OSTI]

INTELLIGENT ENERGY MANAGEMENT AGENT FOR A PARALLEL HYBRID VEHICLE A Dissertation by JONG-SEOB WON Submitted to the O ce of Graduate Studies of Texas A&M University in partial ful llment of the requirements for the degree of DOCTOR OF PHILOSOPHY May... 2003 Major Subject: Mechanical Engineering INTELLIGENT ENERGY MANAGEMENT AGENT FOR A PARALLEL HYBRID VEHICLE A Dissertation by JONG-SEOB WON Submitted to Texas A&M University in partial ful llment of the requirements for the degree of DOCTOR...

Won, Jong-Seob

2004-09-30T23:59:59.000Z

128

Energy Management in Wireless Sensor Network Operations  

E-Print Network [OSTI]

) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 9 Comparison of long-run average costs of policies in 4-node line network (ct = 1 and T = 1) . . . . . . . . . . . . . . . . . . . . . . . 61 10 Fluid- ow model of an energy harvesting sensor . . . . . . . . . . . . 66 11 Sample path of X(t...) under threshold-based node activation policy . . 69 12 Sample path of X(t) in an exponential on-o environment . . . . . . 76 13 Limiting availability for di erent values of threshold (L) . . . . . . . 78 14 Energy ow model of an energy harvesting...

Mohapatra, Arupa Kumar

2013-07-26T23:59:59.000Z

129

Leveraging residential energy management through the Internet of Things  

E-Print Network [OSTI]

Leveraging residential energy management through the Internet of Things Markus Weiss Engineering into the residential environment contribute significantly to today's energy consumption. However, there exists a lack be achieved with adequate information at hand. Thus, conserving energy in residential spaces requires making

130

Power and Energy Management for Server Systems Ricardo Bianchini  

E-Print Network [OSTI]

, of servers and supporting cooling infrastructures. Research on power and energy management for servers can requests coming from remote clients or other servers. Common examples are Web and application servers consumption have become key concerns in data centers. The peak power consumption dictates the required cooling

Bianchini, Ricardo

131

Energy management for the "Perpignan Mditerrane" agglomeration community  

E-Print Network [OSTI]

for the hybrid PV- wind system in "Perpignan Méditerranée" with four strategies of back-up electricity power the electricity demand. Keywords: Energy management, renewable energy, back-up power, virtual power plant. 1 the EU-27 average (31%). In 2004, the 59 installed nuclear power plants produced more than 115 Mtoe

Paris-Sud XI, Université de

132

New Technology Demonstration Program FEMPFederal Energy Management Program  

E-Print Network [OSTI]

Efficiency and Renewable Energy, Federal Energy Management Program, of the U.S. Department of Energy under federal facilities, the fastest growing end-use of electric energy is found in concentrations of computing to their agency mission will present a serious challenge to meeting the aggressive new energy efficiency goals

133

ESSES 2003 2003, Carla Schlatter Ellis Energy Management  

E-Print Network [OSTI]

1 ESSES 2003© 2003, Carla Schlatter Ellis Energy Management at Upper Levels of System Design Carla Schlatter Ellis Systems & Architecture Milly Watt Project 2ESSES 2003© 2003, Carla Schlatter Ellis Energy Watt Project #12;2 3ESSES 2003© 2003, Carla Schlatter Ellis Energy should be a "first class" resource

Ellis, Carla

134

An Experimental Survey of Energy Management Across the Stack  

E-Print Network [OSTI]

that effective parallelization and compiler optimiza- tions have the potential to save far more energy than LinuxAn Experimental Survey of Energy Management Across the Stack Melanie Kambadur Columbia University for energy-efficient computation has spurred research at all levels of the stack, from devices to microarchi

135

Optimal Privacy-Preserving Energy Management for Smart Meters  

E-Print Network [OSTI]

Optimal Privacy-Preserving Energy Management for Smart Meters Lei Yang, Xu Chen, Junshan Zhang Abstract--Smart meters, designed for information collection and system monitoring in smart grid, report a tradeoff between the smart meter data privacy and the electricity bill. In general, a major challenge

Reisslein, Martin

136

190 India Infrastructure Report 2006 URBAN ENERGY MANAGEMENT  

E-Print Network [OSTI]

to reach you news about your city and your area, especially to gauge when electricity might be restored190 India Infrastructure Report 2006 URBAN ENERGY MANAGEMENT Prem K. Kalra and Rajiv Shekhar 9 I ndia's cities are the engines of her economic growth. To provide an environment conducive to the buzz

Columbia University

137

SOC/SIP for energy management Bernard COURTOIS  

E-Print Network [OSTI]

a major issue for the world. Several domains are reviewed like equipment, buildings, lighting, transport for energy management can be obtained from CMP that is briefly reviewed. Keywords: energy, power, CO2 to be even more important. This paper has 4 external sources: the IEA to G8 policy recommendations, in terms

Boyer, Edmond

138

Optimal Energy Management Strategy including Battery Health through Thermal  

E-Print Network [OSTI]

: Energy management strategy, Plug-in hybrid electric vehicles, Li-ion battery aging, thermal management process of Li-ion batteries is very intricate and is currently the subject of many studies, Gyan et al interested in a thorough analysis on Li-ion battery aging can refer to Vetter et al. (2005), Broussely et al

Paris-Sud XI, Université de

139

advanced energy management: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

energy management First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Graduate Catalog 2013-2014 Advanced...

140

Our Favorite Energy Management Opportunities: A Review of Over 150 Energy Audits of Industrial Firms  

E-Print Network [OSTI]

For five years the Oklahoma Industrial Energy Management Program at Oklahoma State University has been serving industry by offering energy audits and energy management conferences. To date, more than 50 conferences and 170 energy audits have been...

Webb, R. E.; Lewis, M.; Spivey, V.; Knight, N.; Turner, W. C.

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Job Task Analysis: Energy Manager; November 2013 - December 2014  

SciTech Connect (OSTI)

This report describes the process for and results of a comprehensive job task analysis of Energy Managers. This study was performed by Professional Testing on behalf of the National Renewable Energy Laboratory (NREL). The competency (domains, tasks and associated knowledge) list, which defines the work performed by practitioners, was initially developed by a representative panel of practitioners during a meeting held on January 22?24, 2014 in Orlando Florida. Following the identification of the job tasks and associated knowledge and skills, a validation survey was conducted of the finding of the JTA and the results of the validation study were reviewed by a representative panel of practitioners during a conference call held on June 2, 2014. The committee finalized the JTA and examination blueprints for the Energy Manager credential scheme based on the survey results.

Woodley, C. D.

2015-01-01T23:59:59.000Z

142

Peer Review of the Federal Energy Management Program Energy-Efficient Product Procurement Portfolio  

Broader source: Energy.gov [DOE]

Document details the peer review of the Federal Energy Management Program Energy-Efficient Product Procurement portfolio.

143

Predictive energy Optimization: The Next Generation of Energy Management  

E-Print Network [OSTI]

energy management systems. A quantum leap in building intelligence is required to close the gap between the current state of building operations and the needs of smart grids and smart cities. Unfortunately for the building HVAC controls industry... information and other information and make informed decisions. These informed decisions present the quantum leap required to bridge the gap between buildings run on rules of thumb to the smart buildings required by smart grids and smart cities. Figure...

Dickinson, P.

2013-01-01T23:59:59.000Z

144

Energy Management and Control System: Desired Capabilities and Functionality  

SciTech Connect (OSTI)

This document discusses functions and capabilities of a typical building/facility energy management and control systems (EMCS). The overall intent is to provide a building operator, manager or engineer with basic background information and recommended functions, capabilities, and good/best practices that will enable the control systems to be fully utilized/optimized, resulting in improved building occupant quality of life and more reliable, energy efficient facilities.

Hatley, Darrel D.; Meador, Richard J.; Katipamula, Srinivas; Brambley, Michael R.; Wouden, Carl

2005-04-29T23:59:59.000Z

145

Energy management systems for commercial buildings. Final report  

SciTech Connect (OSTI)

Increasing costs of energy and the development of lower cost microelectronics have created a growing market for energy management systems applied to commercial buildings. This report examines the spectrum of EMS available and how they are used in different types of commercial buildings. An informal survey of 197 commercial building owners provided additional information on EMS installed and the energy savings attributed to those systems. Evaluations were performed to identify types of EMS appropriate to specific types of commercial buildings.

Woody, A.W.

1986-02-01T23:59:59.000Z

146

Become an Energy Management Professional | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative FuelsBSCmemo.pdf BSCmemo.pdf BSCmemo.pdf More DocumentsEnergy Management Professional

147

Federal Energy Management Success Stories | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: AlternativeEnvironment, Safety and HealthDepartment of EnergyFederal Energy ManagementEnergy

148

Smart Energy Management of Multiple Full Cell Powered Applications  

SciTech Connect (OSTI)

In this research project the University of South Alabama research team has been investigating smart energy management and control of multiple fuel cell power sources when subjected to varying demands of electrical and thermal loads together with demands of hydrogen production. This research has focused on finding the optimal schedule of the multiple fuel cell power plants in terms of electric, thermal and hydrogen energy. The optimal schedule is expected to yield the lowest operating cost. Our team is also investigating the possibility of generating hydrogen using photoelectrochemical (PEC) solar cells through finding materials for efficient light harvesting photoanodes. The goal is to develop an efficient and cost effective PEC solar cell system for direct electrolysis of water. In addition, models for hydrogen production, purification, and storage will be developed. The results obtained and the data collected will be then used to develop a smart energy management algorithm whose function is to maximize energy conservation within a managed set of appliances, thereby lowering O/M costs of the Fuel Cell power plant (FCPP), and allowing more hydrogen generation opportunities. The Smart Energy Management and Control (SEMaC) software, developed earlier, controls electrical loads in an individual home to achieve load management objectives such that the total power consumption of a typical residential home remains below the available power generated from a fuel cell. In this project, the research team will leverage the SEMaC algorithm developed earlier to create a neighborhood level control system.

Mohammad S. Alam

2007-04-23T23:59:59.000Z

149

Stochastic Modeling and Optimization for Energy Management in Multi-Core Systems  

E-Print Network [OSTI]

1 Stochastic Modeling and Optimization for Energy Management in Multi-Core Systems: A Video and optimization framework which leads to effective energy management policies. At the heart of this framework lie to obtain optimal energy management policies. These policies minimize the average energy consumption using

Tasiran, Serdar

150

Energy Management for Hypervisor-Based Virtual Machines Jan Stoess Christian Lang Frank Bellosa  

E-Print Network [OSTI]

Energy Management for Hypervisor-Based Virtual Machines Jan Stoess Christian Lang Frank Bellosa management. Guest level energy management thereby relies on effective virtualiza- tion of physical energy-specific knowledge during device allocation to achieve dy- namic and comprehensive energy management. Modern VM

Yang, Junfeng

151

Efficient Energy Management Policies for Networks with Energy Harvesting Sensor Nodes  

E-Print Network [OSTI]

Efficient Energy Management Policies for Networks with Energy Harvesting Sensor Nodes Vinod Sharma at that time at the node. For such networks we develop efficient energy management policies. First for the largest possible data rate. Next we obtain energy management policies which minimize the mean delay

Sharma, Vinod

152

Energy management of HEV to optimize fuel consumption and pollutant emissions  

E-Print Network [OSTI]

AVEC'12 Energy management of HEV to optimize fuel consumption and pollutant emissions Pierre Michel, several energy management strategies are proposed to optimize jointly the fuel consumption and pollutant-line strategy are given. Keywords: Hybrid Electric Vehicle (HEV), energy management, pollution, fuel consumption

Paris-Sud XI, Université de

153

Near Optimal Demand-Side Energy Management Under Real-time Demand-Response Pricing  

E-Print Network [OSTI]

Near Optimal Demand-Side Energy Management Under Real-time Demand-Response Pricing Jin Xiao, Jae--In this paper, we present demand-side energy manage- ment under real-time demand-response pricing as a task, demand-response, energy management I. INTRODUCTION The growing awareness of global climate change has

Boutaba, Raouf

154

Division of IT Convergence Engineering Optimal Demand-Side Energy Management Under  

E-Print Network [OSTI]

Division of IT Convergence Engineering Optimal Demand-Side Energy Management Under Real-time Demand of appliance specific adapters. Designed and implemented GHS Modeled the demand-side energy management problem (NP-hard) Designed a scheduling algorithm for demand side energy management Showed that our

Boutaba, Raouf

155

Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings  

E-Print Network [OSTI]

Issue on Microgrids and Energy Management 3. Marnay, C. , G.Issue on Microgrids and Energy Management 15. PG&E tariffs (Issue on Microgrids and Energy Management Figures Figure 1.

Stadler, Michael

2010-01-01T23:59:59.000Z

156

Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings  

E-Print Network [OSTI]

and Energy Management in Zero-Net-Energy Buildings Michaeland Energy Management in Zero-Net-Energy Buildings 1 Michaelgoal of achieving zero-net-energy commercial buildings (

Stadler, Michael

2010-01-01T23:59:59.000Z

157

Web-Based Services for Building Energy Management - WEBE  

E-Print Network [OSTI]

WEB-BASED SERVICES FOR BUILDING ENERGY MANAGEMENT ? WEBE Satu Paiho, Jorma Pietil?inen & Mia Ala-Juusela VTT Building and Transport, P.O.Box 1800, FI-02044 VTT, Finland, Email: firstname.lastname@vtt.fi Summary Nowadays, internet can...-line fault diagnosis using Internet and WWW-pages. In: Computers in the Practice of Building and Civil Engineering. Worldwide Symposium. Lahti, Finland, 3-5 Sept. 1997, pp. 362 - 366. 3. Pakanen, J., M?tt?nen, V. & Hyytinen, M. 2001. Prototyping a www...

Paiho, S.; Pietilainen, J.; Ala-Juusela, M.

2004-01-01T23:59:59.000Z

158

The electricity consumption impacts of commercial energy management systems  

SciTech Connect (OSTI)

An investigation of energy management systems (EMS) in large commercial and institutional buildings in North Carolina was undertaken to determine how EMS currently affect electricity consumption and what their potential is for being used to reduce on-peak electricity demand. A survey was mailed to 5000 commercial customers; the 430 responses were tabulated and analyzed; EMS vendors were interviewed, and 30 sites were investigated in detail. The detailed assessments included a site interview and reconstruction of historic billing data to evaluate EMS impact, if any. The results indicate that well-tuned EMS can result in a 10 to 40 percent reduction in billed demand, and smaller reductions in energy.

Buchanan, S.; Taylor, R.; Paulos, S.; Warren, W.; Hay, J.

1989-02-01T23:59:59.000Z

159

Data-Driven, Strategic Energy Management | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA - U.S. DepartmenttoJune 16,AprilFrank G.Strategic energy management

160

Federal Energy Management Success Stories | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA5 &ofDepartment of EnergyEnergy Management Program

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Assessment of Non-traditional Isotopic Ratios by Mass Spectrometry for Analysis of Nuclear Activities: Annual Report Year 2  

SciTech Connect (OSTI)

The objective of this work is to identify isotopic ratios suitable for analysis via mass spectrometry that distinguish between commercial nuclear reactor fuel cycles, fuel cycles for weapons grade plutonium, and products from nuclear weapons explosions. Methods will also be determined to distinguish the above from medical and industrial radionuclide sources. Mass spectrometry systems will be identified that are suitable for field measurement of such isotopes in an expedient manner. Significant progress has been made with this project within the past year: (1) Isotope production from commercial nuclear fuel cycles and nuclear weapons fuel cycles have been modeled with the ORIGEN and MCNPX codes. (2) MCNPX has been utilized to calculate isotopic inventories produced in a short burst fast bare sphere reactor (to approximate the signature of a nuclear weapon). (3) Isotopic ratios have been identified that are good for distinguishing between commercial and military fuel cycles as well as between nuclear weapons and commercial nuclear fuel cycles. (4) Mass spectrometry systems have been assessed for analysis of the fission products of interest. (5) A short-list of forensic ratios have been identified that are well suited for use in portable mass spectrometry systems.

Biegalski, S; Buchholz, B

2009-08-26T23:59:59.000Z

162

Wireless Sensor Network for Advanced Energy Management Solutions  

SciTech Connect (OSTI)

Eaton has developed an advanced energy management solution that has been deployed to several Industries of the Future (IoF) sites. This demonstrated energy savings and reduced unscheduled downtime through an improved means for performing predictive diagnostics and energy efficiency estimation. Eaton has developed a suite of online, continuous, and inferential algorithms that utilize motor current signature analysis (MCSA) and motor power signature analysis (MPSA) techniques to detect and predict the health condition and energy usage condition of motors and their connect loads. Eaton has also developed a hardware and software platform that provided a means to develop and test these advanced algorithms in the field. Results from lab validation and field trials have demonstrated that the developed advanced algorithms are able to detect motor and load inefficiency and performance degradation. Eaton investigated the performance of Wireless Sensor Networks (WSN) within various industrial facilities to understand concerns about topology and environmental conditions that have precluded broad adoption by the industry to date. A Wireless Link Assessment System (WLAS), was used to validate wireless performance under a variety of conditions. Results demonstrated that wireless networks can provide adequate performance in most facilities when properly specified and deployed. Customers from various IoF expressed interest in applying wireless more broadly for selected applications, but continue to prefer utilizing existing, wired field bus networks for most sensor based applications that will tie into their existing Computerized Motor Maintenance Systems (CMMS). As a result, wireless technology was de-emphasized within the project, and a greater focus placed on energy efficiency/predictive diagnostics. Commercially available wireless networks were only utilized in field test sites to facilitate collection of motor wellness information, and no wireless sensor network products were developed under this project. As an outgrowth of this program, Eaton developed a patented energy-optimizing drive control technology that is complementary to a traditional variable frequency drives (VFD) to enable significant energy savings for motors with variable torque applications, such as fans, pumps, and compressors. This technology provides an estimated energy saving of 2%-10% depending on the loading condition, in addition to the savings obtained from a traditional VFD. The combination of a VFD with the enhanced energy-optimizing controls will provide significant energy savings (10% to 70% depending on the load and duty cycle) for motors that are presently connected with across the line starters. It will also provide a more favorable return on investment (ROI), thus encouraging industries to adopt VFDs for more motors within their facilities. The patented technology is based on nonintrusive algorithms that estimate the instantaneous operating efficiency and motor speed and provide active energy-optimizing control of a motor, using only existing voltage and current sensors. This technology is currently being commercialized by Eaton’s Industrial Controls Division in their next generation motor control products. Due to the common nonintrusive and inferential nature of various algorithms, this same product can also include motor and equipment condition monitoring features, providing the facility owner additional information to improve process uptime and the associated energy savings. Calculations estimated potential energy savings of 261,397GWh/Yr ($15.7B/yr), through retrofitting energy-optimizing VFDs into existing facilities, and incorporating the solution into building equipment sold by original equipment manufacturers (OEMs) and installed by mechanical and electrical contractors. Utilizing MCSA and MPSA for predictive maintenance (PM) of motors and connected equipment reduces process downtime cost and the cost of wasted energy associated with shutting down and restarting the processes. Estimated savings vary depending on the industry segment and equi

Peter J. Theisen; Bin Lu, Charles J. Luebke

2009-09-23T23:59:59.000Z

163

Strategic Energy Management Plan For Fort Buchanan, Puerto Rico  

SciTech Connect (OSTI)

This document reports findings and recommendations as a result of a design assistance project with Fort Buchanan with the goals of developing a Strategic Energy Management Plan for the Site. A strategy has been developed with three major elements in mind: 1) development of a strong foundation from which to build, 2) understanding technologies that are available, and 3) exploring financing options to fund the implementation of improvements. The objective of this report is to outline a strategy that can be used by Fort Buchanan to further establish an effective energy management program. Once a strategy is accepted, the next step is to take action. Some of the strategies defined in this Plan may be implemented directly. Other strategies may require the development of a more sophisticated tactical, or operational, plan to detail a roadmap that will lead to successful realization of the goal. Similarly, some strategies are not single events. Rather, some strategies will require continuous efforts to maintain diligence or to change the culture of the Base occupants and their efforts to conserve energy resources.

Parker, Steven A.; Hunt, W. D.

2001-10-31T23:59:59.000Z

164

Post-Retrocommissioning HVAC Operations Monitoring Using Enterprise-Wide energy Management System  

E-Print Network [OSTI]

Post-retrocommissioning HVAC Operations Monitoring Using Enterprise-wide Energy Management System Narendra Amarnani Project Manager Brian Roberts Section Manager County of Los Angeles – ISD Los Angeles, California, USA Howard Choy... earned a graduate degree from Cal Poly University, Pomona. He is a Certified Energy Manager, a LEED® AP, and a Certified Energy Plan Examiner. Brian’s is the Section Manager of the Systems Section within Energy Management Division. His...

Amarnani, N.; Roberts, B.; Choy, H.

2007-01-01T23:59:59.000Z

165

Energy Management A Program of Energy Conservation for the Community College Facility  

E-Print Network [OSTI]

I [] c== l-~~-~ Energy Conservation Checklist and BuildingFREEZERS Some important energy conservation principles thatEnergy Management and Energy Conservation Practices for the

Authors, Various

2011-01-01T23:59:59.000Z

166

Urban energy management: a course on the administration of public energy programs. An instructor's guide  

SciTech Connect (OSTI)

The course provides local government administrators, staff, and students with the background knowledge to deal with a broad range of energy management concerns and is not to train technical energy conservation specialists. Section II contains the Instructor's Guide and Section III provides the Student Outlines and Handouts on the following subjects: The Energy Problem; National Energy Politics and Programs; State and Local Energy Programs; Techniques of Energy Planning; Techniques of Energy Conservation; Techniques of Renewable Energy Production; Strategies for Voluntary Energy Management; Strategies for Finan. Energy Management; and Strategies for Mandatory Energy Management. (MCW)

Mandelbaum, Dr., Len; Olsen, Dr., Marvin; Hyman, Dr., Barry; Sheridan, Mimi; Dahlberg, Judy; O'Brien, Jeremy

1980-12-01T23:59:59.000Z

167

Coordinated Home Energy Management for Real-Time Power Balancing  

E-Print Network [OSTI]

This paper proposes a coordinated home energy management system (HEMS) architecture where the distributed residential units cooperate with each other to achieve real-time power balancing. The economic benefits for the retailer and incentives for the customers to participate in the proposed coordinated HEMS program are given. We formulate the coordinated HEMS design problem as a dynamic programming (DP) and use approximate DP approaches to efficiently handle the design problem. A distributed implementation algorithm based on the convex optimization based dual decomposition technique is also presented. Our focus in the current paper is on the deferrable appliances, such as Plug-in (Hybrid) Electric Vehicles (PHEV), in view of their higher impact on the grid stability. Simulation results shows that the proposed coordinated HEMS architecture can efficiently improve the real-time power balancing.

Chang, Tsung-Hui; Scaglione, Anna

2012-01-01T23:59:59.000Z

168

FEMP (Federal Energy Management Program) presents alternative financing guidance memoranda  

SciTech Connect (OSTI)

Utility financing of energy efficient measures becomes easier to accomplish with the two new alternative financing guidance memoranda, released April 17, 1998, that address the use of utility incentives for Federal facilities. The memoranda have been approved by the Alternative Financing Guidance Committee on the Interagency Energy Management Task Force. The memoranda include: (1) Policy Statement No. 001: Authority to Sole Source Utility Service Contracts as Referenced in Section 152 of the Energy Policy Act (EPACT) of 1992; and (2) Policy Statement No. 002: Congressional Notification for Utility Projects Under the Authority of Section 152 of the Energy Policy Act (EPACT) of 1992. The purpose for developing the financing memoranda was to address specific issues within current Federal procurement regulations that require clarification or guidance. This new guidance will allow for increased use of utility incentives as a means of financing energy efficient and life cycle cost-effective projects in Federal facilities.

NONE

1998-06-01T23:59:59.000Z

169

Accelerator Mass Spectrometric (AMS) Measurements of Plutonium Activity Concentrations and 240Pu/239Pu Atom Ratios In Soil Extracts Supplied by the Carlsbad Environmental Monitoring & Research Center  

SciTech Connect (OSTI)

Plutonium-239 ({sup 239}Pu) and plutonium-239+240 ({sup 239+240}Pu) activities concentrations and {sup 240}Pu/{sup 239}Pu atom ratios are reported for a series of chemically purified soil extracts received from the Carlsbad Environmental Monitoring & Research Center (CEMRC) in New Mexico. Samples were analyzed without further purification at the Lawrence Livermore National Laboratory (LLNL) using accelerator mass spectrometry (AMS). This report also includes a brief description of the AMS system and internal laboratory procedures used to ensure the quality and reliability of the measurement data.

Hamilton, T F; Brown, T A; Marchetti, A A; Martinelli, R E; Kehl, S R

2005-02-28T23:59:59.000Z

170

Distributed Wireless Control for Building Energy Management Alan Marchiori and Qi Han  

E-Print Network [OSTI]

to the total energy efficiency. As building technologies and materi- als improve, the relative impactDistributed Wireless Control for Building Energy Management Alan Marchiori and Qi Han Department building energy management systems are es- sential to enabling the development of mass-market, low- energy

Han, Qi "Chee"

171

A Communication-Based Appliance Scheduling Scheme for Consumer-Premise Energy Management Systems  

E-Print Network [OSTI]

of electricity prices and distributed wind power uncertainty. We model the evolution of the protocol as a two is an energy management controller that incorporates prices and user preferences to providA Communication-Based Appliance Scheduling Scheme for Consumer-Premise Energy Management Systems

Snyder, Larry

172

Statistical Learning Controller for the energy management in a Fuel Cell Electric Vehicle  

E-Print Network [OSTI]

Statistical Learning Controller for the energy management in a Fuel Cell Electric Vehicle M a high efficiency energy management control strategy for a hybrid fuel cell vehicle. The proposed the model of a real hybrid car, "Smile" developed by FAAM, using a stack of fuel cells as the primary power

173

An Efficient Energy Management System for Android Phone Using Bayesian Networks  

E-Print Network [OSTI]

An Efficient Energy Management System for Android Phone Using Bayesian Networks Young-Seol Lee, proximity, light and orientation sensors for context-awareness. Energy-efficient battery management systems, it becomes an issue to develop the techniques for efficient energy management on a mobile phone [2, 3, 4

Cho, Sung-Bae

174

Avoiding the Rush Hours: WiFi Energy Management via Traffic Isolation  

E-Print Network [OSTI]

Avoiding the Rush Hours: WiFi Energy Management via Traffic Isolation Justin Manweiler Duke.rc@duke.edu ABSTRACT WiFi continues to be a prime source of energy consumption in mobile devices. This paper observes that, despite a rich body of research in WiFi energy management, there is room for improvement. Our key

Shihada, Basem

175

Integration of Physical Models in the ORQA Framework for Electric Vehicle Energy Management  

E-Print Network [OSTI]

Integration of Physical Models in the ORQA Framework for Electric Vehicle Energy Management Borjan Brest, France ABSTRACT The energy management of electric vehicles is located in the storage system Systems]: Consumer Products--electric vehicle Keywords model driven architecture; energy consumption

Boyer, Edmond

176

Using Circuit-Level Power Measurements in Household Energy Management Systems  

E-Print Network [OSTI]

Using Circuit-Level Power Measurements in Household Energy Management Systems Alan Marchiori and Qi,qhan}@mines.edu Abstract The first requirement for any intelligent household energy management system is to be able energy consumption, but re- quires a lot of additional hardware­one meter per device in the home

Han, Qi "Chee"

177

Energy Management Strategy for Commercial Buildings Integrating PV and Storage Systems  

E-Print Network [OSTI]

Energy Management Strategy for Commercial Buildings Integrating PV and Storage Systems He ZHANG1 by using the solution proposed. Keywords: Photovoltaic (PV) systems, fuzzy logic, storage system, energy connected to the power network and associated to photovoltaic and storage system. Some energy management

Paris-Sud XI, Université de

178

Wireless Sensors and Networks for Advanced Energy Management  

SciTech Connect (OSTI)

Numerous national studies and working groups have identified low-cost, very low-power wireless sensors and networks as a critical enabling technology for increasing energy efficiency, reducing waste, and optimizing processes. Research areas for developing such sensor and network platforms include microsensor arrays, ultra-low power electronics and signal conditioning, data/control transceivers, and robust wireless networks. A review of some of the research in the following areas will be discussed: (1) Low-cost, flexible multi-sensor array platforms (CO{sub 2}, NO{sub x}, CO, humidity, NH{sub 3}, O{sub 2}, occupancy, etc.) that enable energy and emission reductions in applications such as buildings and manufacturing; (2) Modeling investments (energy usage and savings to drive capital investment decisions) and estimated uptime improvements through pervasive gathering of equipment and process health data and its effects on energy; (3) Robust, self-configuring wireless sensor networks for energy management; and (4) Quality-of-service for secure and reliable data transmission from widely distributed sensors. Wireless communications is poised to support technical innovations in the industrial community, with widespread use of wireless sensors forecasted to improve manufacturing production and energy efficiency and reduce emissions. Progress being made in wireless system components, as described in this paper, is helping bring these projected improvements to reality.

Hardy, J.E.

2005-05-06T23:59:59.000Z

179

Characterizing and Exploiting Task-Load Variability and Correlation for Energy Management in Multi-Core Systems  

E-Print Network [OSTI]

Characterizing and Exploiting Task-Load Variability and Correlation for Energy Management in Multi) Istanbul, Turkey Lausanne, Switzerland Abstract-- We present a hybrid energy management technique of the application. We use the stochastic models in formulating and solving the energy management prob- lem

Tasiran, Serdar

180

PROACTIVE ENERGY MANAGEMENT FOR NEXT-GENERATION BUILDING Victor M. Zavala1, Jianhui Wang2, Sven Leyffer1  

E-Print Network [OSTI]

PROACTIVE ENERGY MANAGEMENT FOR NEXT-GENERATION BUILDING SYSTEMS Victor M. Zavala1, Jianhui Wang2 S Cass Ave, Argonne, IL 60439 ABSTRACT We present a proactive energy management framework that integrates operations will also become significantly more complex. A key conceptual problem of current energy manage

Anitescu, Mihai

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

IEEE TRANSACTIONS ON SMART GRID, VOL. 4, NO. 4, DECEMBER 2013 2139 Dynamic Energy Management for the Smart Grid  

E-Print Network [OSTI]

IEEE TRANSACTIONS ON SMART GRID, VOL. 4, NO. 4, DECEMBER 2013 2139 Dynamic Energy Management for the Smart Grid With Distributed Energy Resources Sergio Salinas, Student Member, IEEE, Ming Li, Student- lenges for energy management in the system. In this paper, we in- vestigate optimal energy management

Fu, Yong

182

Behavioral Energy Management: Improving Conservation Behavior and Attitudes with Operant Conditioning  

E-Print Network [OSTI]

Energy management programs, since their initially glory days, have continued to show “slippage” in their overall effectiveness. The authors discuss behavioral science based ways by which conservation programs can improve effectiveness by mobilizing...

Eibes, T.; Jedlicka, A.

183

Research on Commercial Patterns of China Existing Building Energy Retrofit Based on Energy Management Contract  

E-Print Network [OSTI]

Existing building energy retrofit is one of the keys of building energy efficiency in China. According to experience in developed countries, implementation of energy management contract (EMC) is crucial to promote existing building energy retrofit...

Han, Z.; Liu, C.; Sun, J.

2006-01-01T23:59:59.000Z

184

Why Energy Audits Aren't Enough: An Energy Management System is Required  

E-Print Network [OSTI]

An evaluation of the energy systems in a plant can be accomplished by different techniques which require different levels of effort. Three alternatives are described: Rational Analysis, Energy Audits and Energy Management by Utility Systems Metering...

Haft, A. J.

1980-01-01T23:59:59.000Z

185

Forecasting and Capturing Emission Reductions Using Industrial Energy Management and Reporting Systems  

E-Print Network [OSTI]

The Mandatory 2010 Green House Gas (GHG) Reporting Regulations and pending climate change legislation has increased interest in Energy Management and Reporting Systems (EMRS) as a means of both reducing and reporting GHG emissions. This paper...

Robinson, J.

2010-01-01T23:59:59.000Z

186

An energy management IC for bio-implants using ultracapacitors for energy storage  

E-Print Network [OSTI]

We present the first known energy management IC to allow low-power systems, such as biomedical implants, to optimally use ultracapacitors instead of batteries as their chief energy storage elements. The IC, fabricated in ...

Sanchez, William R.

187

System design and dynamic signature identification for intelligent energy management in residential buildings.  

E-Print Network [OSTI]

Drewer and D. Gann, Smart buildings, Journal of Facilities ,smart energy management system specically for residential buildings.buildings is rooted in relative eectiveness per system by a smart

Jang, Jaehwi

2008-01-01T23:59:59.000Z

188

Rule Based Energy Management and Reporting System (EMRS) Applied to a Large Utility Power Station Complex  

E-Print Network [OSTI]

Deregulation of electricity and rising fuel costs are causing renewed interest in Energy Management Systems (EMS) to service both the utility and private sectors. This paper details a case study of the successful integration of a new class of rule...

Bamber, D.; Childress, R.; Robinson, J.

2004-01-01T23:59:59.000Z

189

Rule-Based Energy Management System Applied to Large Industrial Facilities  

E-Print Network [OSTI]

Deregulation of electricity and rising fuel costs are causing renewed interest in Energy Management Systems (EMS). This paper details the results of integrating a rule-based EMS controller at a Pulp and Paper Mill and additional findings from...

Gauthier, M.; Childress, R. L.

190

Analysis of Energy Management System Control Philosophies Utilizing Collected Field Data  

E-Print Network [OSTI]

Small commercial and light industrial operations are turning to low-cost energy management controllers in efforts to reduce their electrical usage and demand. These controllers offer a variety of techniques to obtain this goal. To study the effects...

Russell, B. D.; Gerloff, G. W.; Heller; R. P.; Perry, L. W.

1983-01-01T23:59:59.000Z

191

Lifecycle Energy Management in the Tohoku Electric Power headquarters building-APCBC  

E-Print Network [OSTI]

Lifecycle Energy Management in the Tohoku Electric Power Company Head Office Building Hideki Yuzawa (NIKKEN SEKKEI Research Institute) Takeshi Kondo (NIKKEN SEKKEI Research Institute) Shinji Okuda (Tohoku Electric Power) APCBC presentation...th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 ICEBO2014 NSRI Hideki Yuzawa ?2014 yuzawa@nikken.jp Passion for sustainable cities 4 What is “Lifecycle energy management” ? 4 #1 Defined the energy...

Yuzawa, H.

2014-01-01T23:59:59.000Z

192

The Energy Manager - Should He Be Working Himself Out Of A Job?  

E-Print Network [OSTI]

and pumping systems, as compared to operating costs including energy costs. This was certainly true of chemi cal, mechanical, electrical, and civil engineers, as well as more specialized types, as they came along. ENERG Y COSTS During that period and up... for the Energy Manager. SUMWlRY I hope that during this discussion we have: 1. Provoked your thinking. 2. Highlighted the need for greater awareness and understanding of energ y parameters by all managers, not just the Energy Manager. 3. Emphasized...

Hogeland, A. W.

1983-01-01T23:59:59.000Z

193

Extension of DOE O 430.2, In-House Energy Management  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Notice extends DOE O 430.2, IN-HOUSE ENERGY MANAGEMENT, dated 6-13-96 until 6-13-01, unless sooner rescinded. The Order is being revised to implement Executive Order 13123, Greening of the Government Through Efficient Energy Management, and a Secretarial Memorandum, Pollution Prevention and Energy Efficiency Leadership Goals, and to include the acquisition, planning and management of utilities. Does not cancel other directives.

2000-12-13T23:59:59.000Z

194

Increase Productivity - Implement Energy Management Systems with Project Management Techniques  

E-Print Network [OSTI]

Engineering Manager of this small but active division, I devote a big part of my time on justifying energy expenditures and the means to reduce these costs. Ten years ago energy costs were one tenth of today's costs and just about three percent of the division...

Spinner, M. P.

1984-01-01T23:59:59.000Z

195

isotopic ratio | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

isotopic ratio isotopic ratio Leads No leads are available at this time. Magnesium behavior and structural defects in Mg+ ion implanted silicon carbide. Abstract: As a candidate...

196

Insights into Corporate Energy Management Trends - Focus on Texas  

E-Print Network [OSTI]

with bureaucratic challenges Copyright ? 2010 Deloitte Development LLC and Harrison Group. All rights reserved. 16 Texas based companies less sold on "Cost of Carbon" Q: How would you describe your attitudes when you hear 'carbon cost' being discussed? Total... how many full-time employees, including yourself, does your company employ? , Q: What were your company?s approximate U.S. revenues last fiscal year?, Q: In what states do you operate? , Q: What is your company?s primary business activity? Copyright...

Fyock, C.

2012-01-01T23:59:59.000Z

197

Energy Management at Steelcase- Energy Integrated with Facilities  

E-Print Network [OSTI]

come up with cost reduction suggestions budget is energy intensive, chief execu? that are implementable, is encouraged to tive officers are not overly involved. manage projects in his responsibility Even many plant engineers and consultants area... the activities of production, our budgeted projects, and any other potential impacts; i.e., fuel switching, etc. DESK PLANT GAS CONSUMPTION 1988, 1989 AND 1990 FORECAST MAR APR MAY .AJN JlA. AUO SEP OCT NOV DEC JAN FEB 'IBCAL YEAR ov?eo CO"8 'OIICA8TED...

Dornbos, D. L.

198

Efficiency improvement of a ground coupled heat pump system from energy management  

E-Print Network [OSTI]

Efficiency improvement of a ground coupled heat pump system from energy management N. Pardo a,*, Á coupled heat pump Energy efficiency Numerical simulation a b s t r a c t The installed capacity of an air to improve the efficiency of a ground coupled heat pump air conditioning system by adapting its produced

Fernández de Córdoba, Pedro

199

The Potential of Energy Management and Control Systems for Real-Time Electricity Pricing Programs  

E-Print Network [OSTI]

provides an opportunity for the utility to implement this network by linking directly with equipment already in place: customer-owned energy management and control systems (EMCS). This paper assesses the potential use of EMCSs in utility real-time pricing...

Akbari, H.; Heinemeier, K. E.

1990-01-01T23:59:59.000Z

200

Comfort-Aware Home Energy Management Under Market-Based Demand-Response  

E-Print Network [OSTI]

pricing and consumption data in South Korea. Index Terms--smart grid, demand-response, energy management I-based pricing. In peak capping, each home is allocated an energy quota. In market-based pricing, the price-term viable way of regulating energy consumptions. We work with day-ahead market pricing in this paper

Boutaba, Raouf

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Project Information Form Project Title Advanced Energy Management Strategy Development for Plug-in Hybrid  

E-Print Network [OSTI]

,365 Total Project Cost $58,365 Agency ID or Contract Number DTRT13-G-UTC29 Start and End Dates April 1, 2014Project Information Form Project Title Advanced Energy Management Strategy Development for Plug ­ September 30, 2015 Brief Description of Research Project Plug-in hybrid vehicles (PHEVs) have great

California at Davis, University of

202

Power and Energy Management for Server Systems Ricardo Bianchini + and Ram Rajamony #  

E-Print Network [OSTI]

, of servers and supporting cooling infrastructures. Research on power and energy management for servers can requests coming from remote clients or other servers. Common examples are Web and application servers consumption have become key concerns in data centers. The peak power consumption dictates the required cooling

Bianchini, Ricardo

203

Department of Energy and Mineral Engineering Spring 2013 Solar Innovations, Inc. Energy Management Program  

E-Print Network [OSTI]

Management Program Overview A team of six energy engineering students was assigned the task of developing an energy management program in order to reduce the client's energy use. The team had 14 weeks (1 semesterPENNSTATE Department of Energy and Mineral Engineering Spring 2013 Solar Innovations, Inc. Energy

Demirel, Melik C.

204

Using a Practical Approach to Energy Management to Get it Done  

E-Print Network [OSTI]

The Wisconsin Focus on Energy program saw a need in 2002 to develop a template for energy management so that companies could easily implement a systematic and continual improvement approach to manage their energy. To meet this need the Focus program...

Nicol, J.; Dantoin, T.

2008-01-01T23:59:59.000Z

205

Energy Management System for an Hybrid Electric Vehicle, Using Ultracapacitors and Neural Networks  

E-Print Network [OSTI]

Energy Management System for an Hybrid Electric Vehicle, Using Ultracapacitors and Neural Networks management system for hybrid electric vehicles (HEV), using neural networks (NN), was developed and tested. The system minimizes the energy requirement of the vehicle and can work with different primary power sources

Catholic University of Chile (Universidad Católica de Chile)

206

OPTIMIZATION WITH ENERGY MANAGEMENT OF PV BATTERY STAND-ALONE SYSTEMS OVER THE ENTIRE LIFE CYCLE  

E-Print Network [OSTI]

of both the installed PV power and storage capacity (lead-acid battery technology for purposes). Keywords: Battery storage and control, Lifetime simulation, PV system. 1. INTRODUCTION Given the sizableOPTIMIZATION WITH ENERGY MANAGEMENT OF PV BATTERY STAND-ALONE SYSTEMS OVER THE ENTIRE LIFE CYCLE

Paris-Sud XI, Université de

207

The Case for Efficient Renewable Energy Management in Smart Binghamton University  

E-Print Network [OSTI]

they produce back to the utility company--to offset their cost relative to grid energy. DG is a much lessThe Case for Efficient Renewable Energy Management in Smart Homes Ting Zhu Binghamton University (DG) uses many small on-site en- ergy sources deployed at individual buildings to generate electricity

Shenoy, Prashant

208

A Supply-Demand Model Based Scalable Energy Management System for Improved Energy  

E-Print Network [OSTI]

the dependency of an electronic system to primary energy sources (i.e. AC power or battery). For reliable energy generation and consumption parameters. The system uses economics inspired supply-demand modelA Supply-Demand Model Based Scalable Energy Management System for Improved Energy Utilization

Bhunia, Swarup

209

Occupancy Modeling and Prediction for Building Energy Management VARICK L. ERICKSON, University of California, Merced  

E-Print Network [OSTI]

42 Occupancy Modeling and Prediction for Building Energy Management VARICK L. ERICKSON, University, University of California, Merced Heating, cooling and ventilation accounts for 35% energy usage in the United into building conditioning system for usage-based demand control conditioning strategies. Using strategies based

Carreira-Perpiñán, Miguel Á.

210

Occupancy-Based Energy Management in Buildings: Final Report to Sponsors  

E-Print Network [OSTI]

1 Occupancy-Based Energy Management in Buildings: Final Report to Sponsors Michael D. Sohn1 Efficiency and Renewable Energy, Office of Building Technology, State and Community Programs of the U Buildings program through the California Institute for Energy and the Environment (CIEE), and by the United

Cerpa, Alberto E.

211

Demo Abstract: Building Energy Management Systems Actuated Using Wireless Camera Sensor Networks  

E-Print Network [OSTI]

Demo Abstract: Building Energy Management Systems Actuated Using Wireless Camera Sensor Networks for approximately 60% of the energy con- sumption within buildings [4]. The conditioning of these ar- eas, however, conditioning (HVAC) sys- tems in residential and commercial buildings account for 50% of the total building

Cerpa, Alberto E.

212

On The Design and Implementation of a Home Energy Management System  

E-Print Network [OSTI]

, Canada email:rboutaba@cs.uwaterloo.ca Abstract--To reduce energy consumption and wastage, effective peak demand. In the effort to reduce energy consumption and wastage, effective home energy management is imple- mented) and their home-wide energy consumption. There is no standard protocol or data format

Boutaba, Raouf

213

Engineering for Environmental Sustainability http://engineering.tufts.edu/ Integrated Data Center Energy Management  

E-Print Network [OSTI]

provided chilled water versus vapor compression refrigeration for enabling room-level AC units) on energy options that connect the electrical, energy supply and consumption and building environmental systems Energy Management What is the problem? Data centers consisting of large numbers of closely packed

Tufts University

214

Optimal Energy Management for a Hybrid Energy Storage System Combining Batteries and Double  

E-Print Network [OSTI]

Optimal Energy Management for a Hybrid Energy Storage System Combining Batteries and Double Layer storage for operation. High demands concerning power and energy density, small volume and weight is to combine storage technologies with complementary characteristics as a hybrid energy storage system. Thus

Paderborn, Universität

215

Energy Management for an Onboard Storage System Based on Multi-Objective Optimization  

E-Print Network [OSTI]

Energy Management for an Onboard Storage System Based on Multi-Objective Optimization Tobias Knoke an onboard energy storage, the overhead line peak power and energy consumption can be reduced. The storage. This can be achieved by using an onboard energy storage, which recuperates the power during the braking

Paderborn, Universität

216

Extension of DOE O 430.2, In-House Energy Management  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order is in the process of being revised to implement E.O. 13123, Greening of the Government Through Efficient Energy Management, and a Secretarial Memorandum, Pollution Prevention and Energy Efficiency Leadership Goals. The revision will also include the acquisition, planning and management of utilities. Does not cancel other directives.

2000-06-13T23:59:59.000Z

217

PipelinePipelineSeptember -October 2009 Volume 1, Issue 8 Energy Management's It All Adds Up  

E-Print Network [OSTI]

.umn.edu/italladdsup FM Safety: Safe Driving is a Full-Time Job continued on page 3 Building occupants take the energyPipelinePipelineSeptember - October 2009 Volume 1, Issue 8 Energy Management's It All Adds Up energy conservation campaign seeks to reduce annual campus energy usage five percent by the end of 2010

Webb, Peter

218

A Compilation Framework for Power and Energy Management on Mobile Computers  

E-Print Network [OSTI]

. Initial experiments show that energy consumption can be reduced signifi­ cantly, in some cases up to oneA Compilation Framework for Power and Energy Management on Mobile Computers Ulrich Kremer #3; Jamey in mobile environments. Image processing can be used in autonomous robot navigation, target acquisition

Kremer, Ulrich

219

Efficient Energy Management and Data Recovery in Sensor Networks using Latent Variables Based Tensor  

E-Print Network [OSTI]

Efficient Energy Management and Data Recovery in Sensor Networks using Latent Variables Based factor in a successful sensor network deployment is finding a good balance between maximizing the number of measurements taken (to maintain a good sampling rate) and minimizing the overall energy consumption (to extend

Simunic, Tajana

220

DEMAND SIDE ENERGY MANAGEMENT AND CONSERVATION PROGRAM Measurement and Verification Program  

E-Print Network [OSTI]

DEMAND SIDE ENERGY MANAGEMENT AND CONSERVATION PROGRAM Measurement and Verification Program 4 operating hours for the lights in each room a. Assign a usage category to each room in all buildings (e electrical usage and savings in room by room spreadsheet d. Subtotal savings by building

Hofmann, Hans A.

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

DEMAND SIDE ENERGY MANAGEMENT AND CONSERVATION PROGRAM Measurement and Verification Program  

E-Print Network [OSTI]

DEMAND SIDE ENERGY MANAGEMENT AND CONSERVATION PROGRAM Measurement and Verification Program 4 Works Association Research Foundation (AwwaRF) and building demographics for savings calculations 4-retrofit; calculate savings in room by room spreadsheet 5. Pre-retrofit (Process water audit) ­ Walk buildings

Hofmann, Hans A.

222

Cascadia Supercycles: Evidence of Clustering and Holocene History of Energy Management from the Long Cascadia Paleoseismic Record  

E-Print Network [OSTI]

Cascadia Supercycles: Evidence of Clustering and Holocene History of Energy Management from attempt to address the issue of energy management over multiple earthquake cycles through the temporal earthquakes is assumed to increase elastic strain energy in proportion to interevent time. We propose

Goldfinger, Chris

223

Energy Management in IaaS Clouds: A Holistic Eugen Feller, Cyril Rohr, David Margery, Christine Morin  

E-Print Network [OSTI]

Energy Management in IaaS Clouds: A Holistic Approach Eugen Feller, Cyril Rohr, David Margery and experimentally evaluated in a realistic environment. In this paper we present the energy management algorithms and mechanisms of a novel holistic energy-aware VM manage- ment framework for private clouds called Snooze. We

Paris-Sud XI, Université de

224

An ANFIS Based Sensor Network for a Residential Energy Management System D. Senthilkumar, S. Kumar, Y. Ozturk and G. Lee  

E-Print Network [OSTI]

An ANFIS Based Sensor Network for a Residential Energy Management System D. Senthilkumar, S. Kumar management system project, an Integrated and Cognitive Home Energy Management System for Demand Response (DR management system which addresses demand response with efficient energy consumption. 1. Introduction State

Kumar, Sunil

225

944 IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, VOL. 4, NO. 4, OCTOBER 2013 Robust Energy Management for Microgrids With  

E-Print Network [OSTI]

944 IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, VOL. 4, NO. 4, OCTOBER 2013 Robust Energy Management of distributed storage (DS) units, and their index. Number of power production facilities with renewable energy to failures, distributed energy management is of para- mount importance in smart grids, especially

Giannakis, Georgios

226

Energy Management System Lowers U.S. Navy Energy Costs Through PV System Interconnection (Fact Sheet)  

SciTech Connect (OSTI)

To meet the U.S. Navy's energy goals, the National Renewable Energy Laboratory (NREL) and the Naval Facilities Engineering Command (NAVFAC) spent two years collaborating on demonstrations that tested market-ready energy efficiency measures, renewable energy generation, and energy systems integration. One such technology - an energy management system - was identified as a promising method for reducing energy use and costs, and can contribute to increasing energy security.

Not Available

2014-04-01T23:59:59.000Z

227

Energy Management of Steam Distribution Systems Through Energy Audits and Computerized Reporting Programs  

E-Print Network [OSTI]

ENERGY KANAGEKBNT OF STEAM DISTRIBUTION SYSTEMS THROUGH BNKRGY AUDITS AND COItPlTl'ERIZED REPORTING PROGRAtIS NORMAN J. RIVERS and HARTIN MANDZUK Armstrong Machine Works, Inc. Three Rivers, Michigan ABSTRACT This presentation will highlight... the economic losses associated with steam distribution systems and how to establish good energy management programs to reduce energy cost by 15 to 25 percent. Recognizing energy losses in steam systems involves I 1. Steam lost through defective valves...

Rivers, N.; Mandzuk, N.

228

Energy Management  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation ProposedUsing Zirconia Nanoparticles asSecondCareerFebruary 2005 1Energy Kits76 B

229

Final Scientific/Technical Report: Context-Aware Smart Home Energy Manager (CASHEM)  

SciTech Connect (OSTI)

Because of growing energy demands and shortages, residential home owners are turning to energy conservation measures and smart home energy management devices to help them reduce energy costs and live more sustainably. In this context, the Honeywell team researched, developed, and tested the Context Aware Smart Home Energy Manager (CASHEM) as a trusted advisor for home energy management. The project focused on connecting multiple devices in a home through a uniform user interface. The design of the user interface was an important feature of the project because it provided a single place for the homeowner to control all devices and was also where they received coaching. CASHEM then used data collected from homes to identify the contexts that affect operation of home appliances. CASHEM�s goal was to reduce energy consumption while keeping the user�s key needs satisfied. Thus, CASHEM was intended to find the opportunities to minimize energy consumption in a way that fit the user�s lifestyle.

Foslien, Wendy K; Curtner, Keith L

2013-01-15T23:59:59.000Z

230

Next-generation building energy management systems and implications for electricity markets.  

SciTech Connect (OSTI)

The U.S. national electric grid is facing significant changes due to aggressive federal and state targets to decrease emissions while improving grid efficiency and reliability. Additional challenges include supply/demand imbalances, transmission constraints, and aging infrastructure. A significant number of technologies are emerging under this environment including renewable generation, distributed storage, and energy management systems. In this paper, we claim that predictive energy management systems can play a significant role in achieving federal and state targets. These systems can merge sensor data and predictive statistical models, thereby allowing for a more proactive modulation of building energy usage as external weather and market signals change. A key observation is that these predictive capabilities, coupled with the fast responsiveness of air handling units and storage devices, can enable participation in several markets such as the day-ahead and real-time pricing markets, demand and reserves markets, and ancillary services markets. Participation in these markets has implications for both market prices and reliability and can help balance the integration of intermittent renewable resources. In addition, these emerging predictive energy management systems are inexpensive and easy to deploy, allowing for broad building participation in utility centric programs.

Zavala, V. M.; Thomas, C.; Zimmerman, M.; Ott, A. (Mathematics and Computer Science); (Citizens Utility Board); (BuildingIQ Pty Ltd, Australia); (PJM Interconnection LLC)

2011-08-11T23:59:59.000Z

231

Energy Management and RD & D Activities for Energy Conservation in TEPCO  

E-Print Network [OSTI]

for some time, and 778 now coal is added to start COM based thermal power development. For all other energy sources natural energies such as geothermal, solar, wind power, tide, ocean thermal energy conversion (OTEC), small scale hydraulic, etc., fuel...

Ohmori, M.; Yoshihama, K.

1981-01-01T23:59:59.000Z

232

Level: National Data; Row: General Energy-Management Activities within NAICS Codes;  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia,(Million Barrels) Crude Oil Reserves in Nonproducing Reservoirs Year in Review1,213 136,422 133,442 140,948844Next1Next

233

Level: National Data; Row: Specific Energy-Management Activities within NAICS Codes;  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia,(Million Barrels) Crude Oil Reserves in Nonproducing Reservoirs Year in Review1,213 136,422 133,4422.49

234

Level: National Data; Row: Specific Energy-Management Activities within NAICS Codes;  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia,(Million Barrels) Crude Oil Reserves in Nonproducing Reservoirs Year in Review1,213 136,422 133,4422.49 Next MECS will

235

" Row: Energy-Management Activities within NAICS Codes;"  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 10 MECSPropane PAD2006..........A49. Total2 End Uses of5 End

236

" Row: Energy-Management Activities within NAICS Codes;"  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 10 MECSPropane PAD2006..........A49. Total2 End Uses of5 End1 Number

237

" Row: General Energy-Management Activities within NAICS Codes;"  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 10 MECSPropane PAD2006..........A49. Total2 End Uses of5 End1

238

" Row: Specific Energy-Management Activities within NAICS Codes;"  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 10 MECSPropane PAD2006..........A49. Total2 End2.1.24 Number of

239

" Row: General Energy-Management Activities within NAICS Codes;"  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 10 MECSPropane PAD2006..........A49. Total2 End2.1.24 Number24681

240

" Row: Specific Energy-Management Activities within NAICS Codes;"  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 10 MECSPropane PAD2006..........A49. Total2 End2.1.24 Number246814

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

A Light-weight Approach to Reducing Energy Management Delays in Disks Guanying Wang, Ali R. Butt, Chris Gniady, Puranjoy Bhattacharjee  

E-Print Network [OSTI]

A Light-weight Approach to Reducing Energy Management Delays in Disks Guanying Wang, Ali R. Butt techniques such as turning machines off overnight and dynamic energy management during the business hours. Unfortunately, dynamic energy management, especially that for disks, introduces delays when an accessed disk

Butt, Ali R.

242

Vehicle to MicroGrid: Leveraging Existing Assets for Reliable Energy Management Mike Simpson, Tony Markel, and Michael O'Keefe  

E-Print Network [OSTI]

Vehicle to MicroGrid: Leveraging Existing Assets for Reliable Energy Management Mike Simpson, Tony Electricity GCV MicroGrid The Smith Electric Newton allelectric truckFort Carson Photovoltaic Installation ENERGY MANAGEMENT BUILDING ENERGY MANAGEMENT GRID OPERATION & RELIABILITY GRID OPERATION & RELIABILITY

243

Evaluation of Cadmium Ratio and Foil Activation Measurements For Beryllium Reflected Assemblies of U(93.15)O2 Fuel Rods (1.506-cm pitch and 7-tube clusters)  

SciTech Connect (OSTI)

A series of small, compact critical assembly (SCCA) experiments were completed from 1962 to 1965 at Oak Ridge National Laboratory’s Critical Experiments Facility (ORCEF) in support of the Medium-Power Reactor Experiments (MPRE) program. Initial experiments, performed in November and December of 1962, consisted of a core of un-moderated stainless-steel tubes, each containing 26 UO2 fuel pellets, surrounded by a graphite reflector. Measurements were performed to determine critical reflector arrangements, fission-rate distributions, and cadmium ratio distributions. The graphite reflectors were then changed to beryllium reflectors. For the beryllium reflected assemblies, the fuel was in 1.506-cm-triangular and 7-tube clusters leading to two critical configurations. Once the critical configurations had been achieved, various measurements of reactivity, relative axial and radial activation rates of 235U, and cadmium ratios were performed. The cadmium ratio, reactivity, and activation rate measurements, performed on the 1.506-cm-array critical configuration, have been evaluated and are described in this paper.

Margaret A. Marshall

2014-12-01T23:59:59.000Z

244

Launched in 2006, the Energy Management Concentration at the Haskayne School of Business provides students with basic  

E-Print Network [OSTI]

Launched in 2006, the Energy Management Concentration at the Haskayne School of Business provides students with basic concepts, principles, and information for managing energy operations. Developed Traders/Commodities Analysts Energy Negotiations Energy Project Management These three areas provide

Habib, Ayman

245

US Air Force Facility Energy Management Program - How Industry Can Help the Air Force Meet Its Objectives  

E-Print Network [OSTI]

This paper describes the Air Force's facility energy management program including how industry can help the Air Force meet its facility energy objectives. Background information on energy use and energy conservation efforts are presented to give...

Holden, P. C.; Kroop, R. H.

1983-01-01T23:59:59.000Z

246

EMSL - isotopic ratio  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

isotopic-ratio en Magnesium behavior and structural defects in Mg+ ion implanted silicon carbide. http:www.emsl.pnl.govemslwebpublicationsmagnesium-behavior-and-structural-def...

247

Burnup estimation of fuel sourcing radioactive material based on monitored Cs and Pu isotopic activity ratios in Fukushima N. P. S. accident  

SciTech Connect (OSTI)

After the severe core damage of Fukushima Dai-Ichi Nuclear Power Station, radioactive material leaked from the reactor buildings. As part of monitoring of radioactivity in the site, measurements of radioactivity in soils at three fixed points have been performed for {sup 134}Cs and {sup 137}Cs with gamma-ray spectrometry and for Pu, Pu, and {sup 240}Pu with {alpha}-ray spectrometry. Correlations of radioactivity ratios of {sup 134}Cs to {sup 137}Cs, and {sup 238}Pu to the sum of {sup 239}Pu and {sup 240}Pu with fuel burnup were studied by using theoretical burnup calculations and measurements on isotopic inventories, and compared with the Cs and Pu radioactivity rations in the soils. The comparison indicated that the burnup of the fuel sourcing the radioactivity was from 18 to 38 GWd/t, which corresponded to that of the fuel in the highest power and, therefore, the highest decay heat in operating high-burnup fueled BWR cores. (authors)

Yamamoto, T.; Suzuki, M.; Ando, Y. [Japan Nuclear Energy Safety Organization, Toranomon Towers Office, 14F, 4-1-28, Toranomon, Minato-ku, Tokyo 105-0001 (Japan)

2012-07-01T23:59:59.000Z

248

The FEMP Awards Program: Fostering Institutional Change and Energy Management Excellence  

SciTech Connect (OSTI)

This report assesses the use of institutional change principles and the institutional impact of award-winning projects through interviews with 22 Department of Energy Federal Energy Management Program (DOE FEMP) award winners. Award winners identified institutional facilitators and barriers in their projects and programs as well as factors in their implementation processes, thus providing information that can guide other efforts. We found that award winners do use strategies based on eight principles of institutional change, most frequently in terms of making changes to infrastructure, engaging leadership, and capitalizing on multiple motivations for making an energy efficiency improvement. The principles drawn on the least often were commitment and social empowerment. Award winners also faced five major types of obstacles that were institutional in nature: lack of resources, constraints of rules, psychological barriers, lack of information, and communication problems. We also used the seven categories of Energy Management Excellence (EME) as a lens to interpret the interview data and assess whether these categories relate to established institutional change principles. We found that the eight principles reflect strategies that have been found to be useful in improving energy efficiency in organizations, whereas the EME categories capture more of a blend of social contextual factors and strategies. The EME categories fill in some of the social context gaps that facilitate institutional change and energy management excellence, for example, personal persistence, a culture that supports creativity and innovation, regular engagement with tenants, contractors, and staff at all levels. Taking together the use of principles, EME criteria, and obstacles faced by interviewees, we make recommendations for how FEMP can better foster institutional change in federal agencies.

McDermott, Christa; Malone, Elizabeth L.

2014-05-20T23:59:59.000Z

249

Thinking Globally: How ISO 50001 - Energy Management can make industrial energy efficiency standard practice  

SciTech Connect (OSTI)

Industry utilizes very complex systems, consisting of equipment and their human interface, which are organized to meet the production needs of the business. Effective and sustainable energy efficiency programs in an industrial setting require a systems approach to optimize the integrated whole while meeting primary business requirements. Companies that treat energy as a manageable resource and integrate their energy program into their management practices have an organizational context to continually seek opportunities for optimizing their energy use. The purpose of an energy management system standard is to provide guidance for industrial and commercial facilities to integrate energy efficiency into their management practices, including fine-tuning production processes and improving the energy efficiency of industrial systems. The International Organization for Standardization (ISO) has identified energy management as one of its top five priorities for standards development. The new ISO 50001 will establish an international framework for industrial, commercial, or institutional facilities, or entire companies, to manage their energy, including procurement and use. This standard is expected to achieve major, long-term increases in energy efficiency (20percent or more) in industrial, commercial, and institutional facilities and to reduce greenhouse gas (GHG) emissions worldwide.This paper describes the impetus for the international standard, its purpose, scope and significance, and development progress to date. A comparative overview of existing energy management standards is provided, as well as a discussion of capacity-building needs for skilled individuals to assist organizations in adopting the standard. Finally, opportunities and challenges are presented for implementing ISO 50001 in emerging economies and developing countries.

McKane, Aimee; Desai, Deann; Matteini, Marco; Meffert, William; Williams, Robert; Risser, Roland

2009-08-01T23:59:59.000Z

250

Web-based energy information systems for energy management and demand response in commercial buildings  

SciTech Connect (OSTI)

Energy Information Systems (EIS) for buildings are becoming widespread in the U.S., with more companies offering EIS products every year. As a result, customers are often overwhelmed by the quickly expanding portfolio of EIS feature and application options, which have not been clearly identified for consumers. The object of this report is to provide a technical overview of currently available EIS products. In particular, this report focuses on web-based EIS products for large commercial buildings, which allow data access and control capabilities over the Internet. EIS products combine software, data acquisition hardware, and communication systems to collect, analyze and display building information to aid commercial building energy managers, facility managers, financial managers and electric utilities in reducing energy use and costs in buildings. Data types commonly processed by EIS include energy consumption data; building characteristics; building system data, such as heating, ventilation, and air-conditioning (HVAC) and lighting data; weather data; energy price signals; and energy demand-response event information. This project involved an extensive review of research and trade literature to understand the motivation for EIS technology development. This study also gathered information on currently commercialized EIS. This review is not an exhaustive analysis of all EIS products; rather, it is a technical framework and review of current products on the market. This report summarizes key features available in today's EIS, along with a categorization framework to understand the relationship between EIS, Energy Management and Control Systems (EMCSs), and similar technologies. Four EIS types are described: Basic Energy Information Systems (Basic-EIS); Demand Response Systems (DRS); Enterprise Energy Management (EEM); and Web-based Energy Management and Control Systems (Web-EMCS). Within the context of these four categories, the following characteristics of EIS are discussed: Metering and Connectivity; Visualization and Analysis Features; Demand Response Features; and Remote Control Features. This report also describes the following technologies and the potential benefits of incorporating them into future EIS products: Benchmarking; Load Shape Analysis; Fault Detection and Diagnostics; and Savings Analysis.

Motegi, Naoya; Piette, Mary Ann; Kinney, Satkartar; Herter, Karen

2003-04-18T23:59:59.000Z

251

Electric Energy Management in the Smart Home: Perspectives on Enabling Technologies and Consumer Behavior: Preprint  

SciTech Connect (OSTI)

Smart homes hold the potential for increasing energy efficiency, decreasing costs of energy use, decreasing the carbon footprint by including renewable resources, and transforming the role of the occupant. At the crux of the smart home is an efficient electric energy management system that is enabled by emerging technologies in the electric grid and consumer electronics. This article presents a discussion of the state-of-the-art in electricity management in smart homes, the various enabling technologies that will accelerate this concept, and topics around consumer behavior with respect to energy usage.

Zipperer, A.; Aloise-Young, P. A.; Suryanarayanan, S.; Roche, R.; Earle, L.; Christensen, D.; Bauleo, P.; Zimmerle. D.

2013-08-01T23:59:59.000Z

252

LESSONS LEARNED FROM CYBER SECURITY ASSESSMENTS OF SCADA AND ENERGY MANAGEMENT SYSTEMS  

SciTech Connect (OSTI)

The results from ten cyber security vulnerability assessments of process control, SCADA and energy management systems, or components of those systems were reviewed to identify common problem areas. The common vulnerabilities ranged from conventional IT security issues to specific weaknesses in control system protocols. In each vulnerability category, relative measures were assigned to the severity of the vulnerability and ease with which an attacker could exploit the vulnerability. Suggested mitigations are identified in each category. Recommended mitigations having the highest impact on reducing vulnerability are listed for asset owners and system vendors.

Ray Fink

2006-10-01T23:59:59.000Z

253

Federal Energy Management Program Procedure for Notifying Congress Prior to Award of ESPCs  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPCofConstructionofFYOxideof1 DOEFederal Energy Management Program's

254

The Wide-area Energy Management System Phase 2 Final Report  

SciTech Connect (OSTI)

The higher penetration of intermittent generation resources (including wind and solar generation) in the Bonneville Power Administration (BPA) and California Independent System Operator (CAISO) balancing authorities (BAs) raises issue of requiring expensive additional fast grid balancing services in response to additional intermittency and fast up and down power ramps in the electric supply system. The overall goal of the wide-area energy management system (WAEMS) project is to develop the principles, algorithms, market integration rules, a functional design, and a technical specification for an energy storage system to help cope with unexpected rapid changes in renewable generation power output. The resulting system will store excess energy, control dispatchable load and distributed generation, and utilize inter-area exchange of the excess energy between the California ISO and Bonneville Power Administration control areas. A further goal is to provide a cost-benefit analysis and develop a business model for an investment-based practical deployment of such a system. There are two tasks in Phase 2 of the WAEMS project: the flywheel field tests and the battery evaluation. Two final reports, the Wide-area Energy Management System Phase 2 Flywheel Field Tests Final Report and the Wide-area Energy Storage and Management System Battery Storage Evaluation, were written to summarize the results of the two tasks.

Lu, Ning; Makarov, Yuri V.; Weimar, Mark R.

2010-08-31T23:59:59.000Z

255

ARM - Measurement - Isotope ratio  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUC : XDCResearch Related InformationAciddropletgovMeasurementsIsotope ratio ARM

256

Stress-wave energy management through material anisotropy Alireza V. Amirkhizi, Aref Tehranian, Sia Nemat-Nasser  

E-Print Network [OSTI]

Stress-wave energy management through material anisotropy Alireza V. Amirkhizi, Aref Tehranian, Sia that if this axis initially coincides with the stress-wave vector, then the energy of the plane waves would closely the required anisotropy, and to experimentally demonstrate the management of stress-wave energy in a desired

Nemat-Nasser, Sia

257

A near-Zero Run-time Energy Overhead within a Computation Outsourcing Framework for Energy Management in Mobile Devices  

E-Print Network [OSTI]

incurring a near-Zero run-time overhead. Key Words- Energy Management, Outsourcing, Smart Spaces, Energy Monitor, Battery Monitor. 1. Introduction Energy/Power management in mobile devices has been and continues and therefore their energy consumption must be managed. The energy problem has been and continues to be tackled

Helal, Abdelsalam

258

614 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 53, NO. 2, APRIL 2006 Energy-Management System for a Hybrid Electric  

E-Print Network [OSTI]

-Management System for a Hybrid Electric Vehicle, Using Ultracapacitors and Neural Networks Jorge Moreno, Member energy-management system for hy- brid electric vehicles (HEVs), using neural networks (NNs was converted to an electric vehicle (EV) at the Universidad Católica de Chile. Numerous experimental tests

Catholic University of Chile (Universidad Católica de Chile)

259

Energy management of power-split plug-in hybrid electric vehicles based on simulated annealing and Pontryagin's minimum principle  

E-Print Network [OSTI]

Energy management of power-split plug-in hybrid electric vehicles based on simulated annealing management method is proposed for a power-split plug-in hybrid electric vehicle (PHEV). Through analyzing and hybrid driving mode. During the pure electric driving mode, the vehicle is only powered by the battery

Mi, Chunting "Chris"

260

Tenant Guidelines National Park Service and the U.S. Department of Energy, Federal Energy Management Program  

E-Print Network [OSTI]

Tenant Guidelines National Park Service and the U.S. Department of Energy, Federal Energy Management Program for Energy-Efficient Renovation of Buildings at the Presidio of San Francisco #12 like to thank the following reviewers for their comments: Anne Sprunt Crawley, Federal Energy

Diamond, Richard

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Peak power ratio generator  

DOE Patents [OSTI]

A peak power ratio generator is described for measuring, in combination with a conventional power meter, the peak power level of extremely narrow pulses in the gigahertz radio frequency bands. The present invention in a preferred embodiment utilizes a tunnel diode and a back diode combination in a detector circuit as the only high speed elements. The high speed tunnel diode provides a bistable signal and serves as a memory device of the input pulses for the remaining, slower components. A hybrid digital and analog loop maintains the peak power level of a reference channel at a known amount. Thus, by measuring the average power levels of the reference signal and the source signal, the peak power level of the source signal can be determined.

Moyer, Robert D. (Albuquerque, NM)

1985-01-01T23:59:59.000Z

262

Occupancy-Based Energy Management in Buildings: Final Report to Sponsors  

SciTech Connect (OSTI)

The Lawrence Berkeley National Laboratory (LBNL), the University of California Merced (UCM), and the United Technologies Research Center (UTRC) conducted field studies and modeling analyses in the Classroom and Office Building (COB) and the Science and Engineering Building (S&E) at the University of California, Merced. In the first year, of a planned multiyear project, our goal was to study the feasibility and efficacy of occupancy-based energy management. The first-year research goals were twofold. The first was to explore the likely energy savings if we know the number and location of building occupants in a typical commercial building. The second was to model and estimate people movement in a building. Our findings suggest that a 10-14percent reduction in HVAC energy consumption is possible over typical HVAC operating conditions when we know occupancy throughout the building. With the conclusion of the first-year tasks, we plan to review these results further before this group pursues follow-on funding.

Sohn, Michael D.; Black, Douglas R.; Price, Phillip N.; Lin, Yiqing; Brahme, Rohini; Surana, Amit; Narayanan, Satish; Cerpa, Alberto; Ericson, Varick; Kamthe, Ankur

2010-07-01T23:59:59.000Z

263

Energy Profit Ratio Compared  

SciTech Connect (OSTI)

We need more oil energy to take out oil under the ground. Limit resources make us consider other candidates of energy source instead of oil. Electricity shall be the main role more and more like electric vehicles and air conditioners so we should consider electricity generation ways. When we consider what kind of electric power generation is the best or suitable, we should not only power generation plant but whole process from mining to power generation. It is good way to use EPR, Energy Profit Ratio, to analysis which type is more efficient and which part is to do research and development when you see the input breakdown analysis. Electricity by the light water nuclear power plant, the hydrogen power plant and the geothermal power plant are better candidates from EPR analysis. Forecasting the world primly energy supply in 2050, it is said that the demand will be double of the demand in 2000 and the supply will not be able to satisfy the demand in 2050. We should save 30% of the demand and increase nuclear power plants 3.5 times more and recyclable energy like hydropower plants 3 times more. When the nuclear power plants are 3.5 times more then uranium peak will come and we will need breed uranium. I will analysis the EPR of FBR. Conclusion: A) the EPR of NPS in Japan is 17.4 and it is the best of all. B) Many countries will introduce new nuclear power plants rapidly may be 3.5 times in 2050. C) Uranium peak will happen around 2050. (author)

Amano, Osamu [2-11-1, Iwado Kita, Komae-shi, Tokyo 201-8511 (Japan)

2007-07-01T23:59:59.000Z

264

Energy Management in Small Commercial Buildings: A Look at How HVAC Contractors Can Deliver Energy Efficiency to this Segment  

SciTech Connect (OSTI)

While buildings smaller than 50,000 sq ft account for nearly half of the energy used in US commercial buildings, energy efficiency programs to-date have primarily focused on larger buildings. Interviews with stakeholders and a review of the literature indicate interest in energy efficiency from the small commercial building sector, provided solutions are simple and low-cost. An approach to deliver energy management to small commercial buildings via HVAC contractors and preliminary demonstration findings are presented. The energy management package (EMP) developed includes five technical elements: benchmarking and analysis of monthly energy use; analysis of interval electricity data (if available), a one-hour onsite walkthrough, communication with the building owner, and checking of results. This data-driven approach tracks performance and identifies low-cost opportunities, using guidelines and worksheets for each element to streamline the delivery process and minimize the formal training required. This energy management approach is unique from, but often complementary to conventional quality maintenance or retrofit-focused programs targeting the small commercial segment. Because HVAC contractors already serve these clients, the transaction cost to market and deliver energy management services can be reduced to the order of hundreds of dollars per year. This business model, outlined briefly in this report, enables the offering to benefit the contractor and client even at the modest expected energy savings in small buildings. Results from a small-scale pilot of this approach validated that the EMP could be delivered by contractors in 4-8 hours per building per year, and that energy savings of 3-5percent are feasible through this approach.

Hult, Erin; Granderson, Jessica; Mathew, Paul

2014-07-01T23:59:59.000Z

265

The New Energy Management Frontier: The Critical Role of a Systematic Management Approach in Making Technology Improvements Successful  

E-Print Network [OSTI]

The New Energy Management Frontier: The Critical Role of a Systematic Management Approach in Making Technology Improvements Successful Jon Feldman Senior Consultant Hatch Consulting Mississauga, Ontario, Canada ABSTRACT Improvements... in technology certainly playa pivotal role in the quest for increased energy efficiency. However, sophisticated industrial energy users are increasingly learning that technology alone cannot drive long-tenn, sustainable reductions in energy cost. The role...

Feldman, J.

266

Mining Building Energy Management System Data Using Fuzzy Anomaly Detection and Linguistic Descriptions  

SciTech Connect (OSTI)

Building Energy Management Systems (BEMSs) are essential components of modern buildings that utilize digital control technologies to minimize energy consumption while maintaining high levels of occupant comfort. However, BEMSs can only achieve these energy savings when properly tuned and controlled. Since indoor environment is dependent on uncertain criteria such as weather, occupancy, and thermal state, performance of BEMS can be sub-optimal at times. Unfortunately, the complexity of BEMS control mechanism, the large amount of data available and inter-relations between the data can make identifying these sub-optimal behaviors difficult. This paper proposes a novel Fuzzy Anomaly Detection and Linguistic Description (Fuzzy-ADLD) based method for improving the understandability of BEMS behavior for improved state-awareness. The presented method is composed of two main parts: 1) detection of anomalous BEMS behavior and 2) linguistic representation of BEMS behavior. The first part utilizes modified nearest neighbor clustering algorithm and fuzzy logic rule extraction technique to build a model of normal BEMS behavior. The second part of the presented method computes the most relevant linguistic description of the identified anomalies. The presented Fuzzy-ADLD method was applied to real-world BEMS system and compared against a traditional alarm based BEMS. In six different scenarios, the Fuzzy-ADLD method identified anomalous behavior either as fast as or faster (an hour or more), that the alarm based BEMS. In addition, the Fuzzy-ADLD method identified cases that were missed by the alarm based system, demonstrating potential for increased state-awareness of abnormal building behavior.

Dumidu Wijayasekara; Ondrej Linda; Milos Manic; Craig Rieger

2014-08-01T23:59:59.000Z

267

Use of Metering for Facility and Whole Building Energy Analysis by the U.S. Depratment of Energy Federal Energy Management Program  

E-Print Network [OSTI]

This paper details how the U.S. Department of Energy, Federal Energy Management Program (FEMP) is applying metering technology to conduct empirically based analyses o f energy use by federal agencies. Continuing developments in sensors, data...

Devine, K. D.; Mazzucchi, R. P.

1989-01-01T23:59:59.000Z

268

Smart Energy Management and Control for Fuel Cell Based Micro-Grid Connected Neighborhoods  

SciTech Connect (OSTI)

Fuel cell power generation promises to be an efficient, pollution-free, reliable power source in both large scale and small scale, remote applications. DOE formed the Solid State Energy Conversion Alliance with the intention of breaking one of the last barriers remaining for cost effective fuel cell power generation. The Alliance’s goal is to produce a core solid-state fuel cell module at a cost of no more than $400 per kilowatt and ready for commercial application by 2010. With their inherently high, 60-70% conversion efficiencies, significantly reduced carbon dioxide emissions, and negligible emissions of other pollutants, fuel cells will be the obvious choice for a broad variety of commercial and residential applications when their cost effectiveness is improved. In a research program funded by the Department of Energy, the research team has been investigating smart fuel cell-operated residential micro-grid communities. This research has focused on using smart control systems in conjunction with fuel cell power plants, with the goal to reduce energy consumption, reduce demand peaks and still meet the energy requirements of any household in a micro-grid community environment. In Phases I and II, a SEMaC was developed and extended to a micro-grid community. In addition, an optimal configuration was determined for a single fuel cell power plant supplying power to a ten-home micro-grid community. In Phase III, the plan is to expand this work to fuel cell based micro-grid connected neighborhoods (mini-grid). The economic implications of hydrogen cogeneration will be investigated. These efforts are consistent with DOE’s mission to decentralize domestic electric power generation and to accelerate the onset of the hydrogen economy. A major challenge facing the routine implementation and use of a fuel cell based mini-grid is the varying electrical demand of the individual micro-grids, and, therefore, analyzing these issues is vital. Efforts are needed to determine the most appropriate means of implementing micro-grids and the costs and processes involved with their extended operation. With the development and availability of fuel cell based stand-alone power plants, an electrical mini-grid, encompassing several connected residential neighborhoods, has become a viable concept. A primary objective of this project is to define the parameters of an economically efficient fuel cell based mini-grid. Since pure hydrogen is not economically available in sufficient quantities at the present time, the use of reforming technology to produce and store excess hydrogen will also be investigated. From a broader perspective, the factors that bear upon the feasibility of fuel cell based micro-grid connected neighborhoods are similar to those pertaining to the electrification of a small town with a localized power generating station containing several conventional generating units. In the conventional case, the town or locality would also be connected to the larger grid system of the utility company. Therefore, in the case of the fuel cell based micro-grid connected neighborhoods, this option should also be available. The objectives of this research project are: To demonstrate that smart energy management of a fuel cell based micro-grid connected neighborhood can be efficient and cost-effective;To define the most economical micro-grid configuration; and, To determine how residential micro-grid connected fuel cell(s) can contribute to America's hydrogen energy future.

Dr. Mohammad S. Alam

2006-03-15T23:59:59.000Z

269

Federal Energy Management Program FY14 Budget At-a-Glance  

Energy Savers [EERE]

UESCs (utility energy service contracts)from the FY 20112012 baseline. Achieve lifecycle Btu Savings of 57 trillion Btu from FY 2014 program activities. The program's...

270

High ratio recirculating gas compressor  

DOE Patents [OSTI]

A high ratio positive displacement recirculating rotary compressor is disclosed. The compressor includes an integral heat exchanger and recirculation conduits for returning cooled, high pressure discharge gas to the compressor housing to reducing heating of the compressor and enable higher pressure ratios to be sustained. The compressor features a recirculation system which results in continuous and uninterrupted flow of recirculation gas to the compressor with no direct leakage to either the discharge port or the intake port of the compressor, resulting in a capability of higher sustained pressure ratios without overheating of the compressor. 10 figs.

Weinbrecht, J.F.

1989-08-22T23:59:59.000Z

271

Annual report to Congress on Federal Government Energy Management and Conservation Programs, Fiscal Year 1997  

SciTech Connect (OSTI)

In fulfillment of statutory requirements, this report provides information on energy consumption in Federal buildings and operations and also documents activities conducted by Federal agencies in fulfilling those requirements during Fiscal Year 1997.

none,

1999-08-13T23:59:59.000Z

272

Annual report to Congress on Federal Government Energy Management and Conservation Programs, Fiscal Year 1998  

SciTech Connect (OSTI)

In fulfillment of statutory requirements, this report provides information on energy consumption in Federal buildings and operations and also documents activities conducted by Federal agencies in fulfilling those requirements during Fiscal Year 1998.

none,

2000-03-20T23:59:59.000Z

273

Annual report to Congress on Federal Government energy management and conservation programs, Fiscal year 1994  

SciTech Connect (OSTI)

This report provides sinformation on energy consumption in Federal buildings and operations and documents activities conducted by Federal agencies to meet statutory requirements of the National Energy Conservation Policy Act. It also describes energy conservation and management activities of the Federal Government under section 381 of the Energy Policy and Conservation Act. Implementation activities undertaken during FY94 by the Federal agencies under the Energy Policy Act of 1992 and Executive Orders 12759 and 12902 are also described. During FY94, total (gross) energy consumption of the US Government, including energy consued to produce, process, and transport energy, was 1.72 quadrillion Btu. This represents {similar_to}2.0% of the total 85.34 quads used in US.

NONE

1995-10-06T23:59:59.000Z

274

Simulation-based design of energy management system with storage battery for a refugee shelter in Japan  

SciTech Connect (OSTI)

Since the massive earthquake hit eastern Japan in March, 2011, our team has participated in the recovery planning for Kesen Association, which is a group of cities in northeastern Japan. As one of our proposals for the recovery planning for the community, we are designing energy management system with renewable energy (RE) and storage batteries. Some public facilities in the area have been used as refugee shelters, but refugees had to put up with life without electricity for a while after the disaster. If RE generator and storage batteries are introduced into the facilities, it is possible to provide refugees with electricity. In this study, the sizes of photovoltaic (PV) appliances and storage batteries to be introduced into one public facility are optimized. The optimization is based on simulation, in which electric energy is managed by charge and discharge of storage battery.

Kaji, K.; Zhang, J.; Horie, H.; Tanaka, K. [Department of Technology Management for Innovation, Graduate School of Engineering, The University of Tokyo (Japan); Akimoto, H. [Korea Advanced Institute of Science and Technology (Korea, Republic of)

2013-12-10T23:59:59.000Z

275

Advanced Hybrid Propulsion and Energy Management System for High Efficiency, Off Highway, 240 Ton Class, Diesel Electric Haul Trucks  

SciTech Connect (OSTI)

The objective of this project is to reduce the fuel consumption of off-highway vehicles, specifically large tonnage mine haul trucks. A hybrid energy storage and management system will be added to a conventional diesel-electric truck that will allow capture of braking energy normally dissipated in grid resistors as heat. The captured energy will be used during acceleration and motoring, reducing the diesel engine load, thus conserving fuel. The project will work towards a system validation of the hybrid system by first selecting an energy storage subsystem and energy management subsystem. Laboratory testing at a subscale level will evaluate these selections and then a full-scale laboratory test will be performed. After the subsystems have been proven at the full-scale lab, equipment will be mounted on a mine haul truck and integrated with the vehicle systems. The integrated hybrid components will be exercised to show functionality, capability, and fuel economy impacts in a mine setting.

Richter, Tim; Slezak, Lee; Johnson, Chris; Young, Henry; Funcannon, Dan

2008-12-31T23:59:59.000Z

276

Use of Energy Management and Control Systems for Performance Monitoring of Retrofit Projects: Final Summary Report for USDOE Office of Conservation and Energy, Final Revision, March 1993  

E-Print Network [OSTI]

ESL-TR-91/09-02 Use of Energy Management and Control Systems for Performance Monitoring of Retrofit Projects Final Summary Report Grant # DE-FG01-90CE21003 David E. Claridge, Ph.D., P.E., Co-Principal Investigator, Jeff S. Haberl, Ph.D., P.E., Co... for Appropriate Technology, Butte, Montana September 1991, First Revision March 1992, Final Revision March 1993 USDOE EMCS Report p. i 1.0 Executive Summary Traditionally, Energy Management and Control Systems (EMCSs) have been used to control HVAC, lighting, fire...

Claridge, D. E.; Haberl, J. S.; Sparks, R. J.; Bryant, J.; Poyner, B.; Belur, R.; Bryant, J.; Akbari, H.; Heinemeier, K. E.; Lippman, R.; McBride, J.

1991-01-01T23:59:59.000Z

277

Social Acceptance of Wind Energy: Managing and Evaluating Its Market Impacts (Presentation)  

SciTech Connect (OSTI)

As with any industrial-scale technology, wind power has impacts. As wind technology deployment becomes more widespread, a defined opposition will form as a result of fear of change and competing energy technologies. As the easy-to-deploy sites are developed, the costs of developing at sites with deployment barriers will increase, therefore increasing the total cost of power. This presentation provides an overview of wind development stakeholders and related stakeholder engagement questions, Energy Department activities that provide wind project deployment information, and the quantification of deployment barriers and costs in the continental United States.

Baring-Gould, I.

2012-06-01T23:59:59.000Z

278

Top Operations and Maintenance (O&M) Efficiency Opportunities at DoD/Army Sites - A Guide for O&M/Energy Managers and Practitioners  

SciTech Connect (OSTI)

This report, sponsored the Army's Energy Engineering Analysis Program, provides the Operations and Maintenance (O&M) Energy manager and practitioner with useful information about the top O&M opportunities consistently found across the DoD/Army sector. The target is to help the DoD/Army sector develop a well-structured and organized O&M program.

Sullivan, Gregory P.; Dean, Jesse D.; Dixon, Douglas R.

2007-05-25T23:59:59.000Z

279

Sustainability Dashboard Quick Start Guide The Sustainability Dashboard is a web based energy management system that allows users to track a  

E-Print Network [OSTI]

energy management system that allows users to track a building's performance, generate reports individual meters, click on Meter Displays under the main menu item, Graphics & Displays. Then select, energy log and time period parameters to generate custom reports. Figure 9: Utility Report Wizard To use

280

Variable ratio regenerative braking device  

DOE Patents [OSTI]

Disclosed is a regenerative braking device (10) for an automotive vehicle. The device includes an energy storage assembly (12) having a plurality of rubber rollers (26, 28) mounted for rotation between an input shaft (36) and an output shaft (42), clutches (38, 46) and brakes (40, 48) associated with each shaft, and a continuously variable transmission (22) connectable to a vehicle drivetrain and to the input and output shafts by the respective clutches. The rubber rollers are torsionally stressed to accumulate energy from the vehicle when the input shaft is clutched to the transmission while the brake on the output shaft is applied, and are torsionally relaxed to deliver energy to the vehicle when the output shaft is clutched to the transmission while the brake on the input shaft is applied. The transmission ratio is varied to control the rate of energy accumulation and delivery for a given rotational speed of the vehicle drivetrain.

Hoppie, Lyle O. (Birmingham, MI)

1981-12-15T23:59:59.000Z

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Weather-Corrected Performance Ratio  

SciTech Connect (OSTI)

Photovoltaic (PV) system performance depends on both the quality of the system and the weather. One simple way to communicate the system performance is to use the performance ratio (PR): the ratio of the electricity generated to the electricity that would have been generated if the plant consistently converted sunlight to electricity at the level expected from the DC nameplate rating. The annual system yield for flat-plate PV systems is estimated by the product of the annual insolation in the plane of the array, the nameplate rating of the system, and the PR, which provides an attractive way to estimate expected annual system yield. Unfortunately, the PR is, again, a function of both the PV system efficiency and the weather. If the PR is measured during the winter or during the summer, substantially different values may be obtained, making this metric insufficient to use as the basis for a performance guarantee when precise confidence intervals are required. This technical report defines a way to modify the PR calculation to neutralize biases that may be introduced by variations in the weather, while still reporting a PR that reflects the annual PR at that site given the project design and the project weather file. This resulting weather-corrected PR gives more consistent results throughout the year, enabling its use as a metric for performance guarantees while still retaining the familiarity this metric brings to the industry and the value of its use in predicting actual annual system yield. A testing protocol is also presented to illustrate the use of this new metric with the intent of providing a reference starting point for contractual content.

Dierauf, T.; Growitz, A.; Kurtz, S.; Cruz, J. L. B.; Riley, E.; Hansen, C.

2013-04-01T23:59:59.000Z

282

Implementing an Energy Management System at TOTAL Prot Arthur Refinery: The process to improving and sustaining energy efficiency performance at a facility.  

E-Print Network [OSTI]

PROPRIETARY INFORMATION? 2011 KBC Advanced Technologies plc. All Rights Reserved. Implementing an Energy Management System at TOTAL Port Arthur Refinery: The process to improving and sustaining energy efficiency performance at a facility May... Improvements ? Cost-savings initiatives ? Increasing environmental awareness ? Increasing throughput by debottlenecking processes ? Increasing government mandates 2May 2013 Energy Costs for a 200kBPD Complex refinery Typically, energy efficiency programs...

Hoyle, A.

2013-01-01T23:59:59.000Z

283

Global Energy Management System  

E-Print Network [OSTI]

? Prize continues to grow -- 500-1000 M$/yr depending on energy prices ? Higher energy prices -- crude oil and natural gas ? Identification of additional and new opportunities ? Adds outpacing drops by greater than 2.5 : 1 margin ? Benefit capture... approaching 50 % -- mainly no/low cost optimizations ? Potential to reduce GHG emissions about 10 million tonnes per year GEMS PRIZE CAPTURE 1998 2004 Prices Drops Adds $ 500-1000 M$/yr Depending on Energy Prices Benefit Capture ~ 45 % Remaining...

Eidt, B. D.

2005-01-01T23:59:59.000Z

284

Strategic Energy Management  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy (DOE) See Action Network and Weatherization and Intergovernmental Program Technical Assistance Program sponsored this webinar about strategic management in the public sector on November 7, 2012.

285

Energy Management at SMARTboard  

E-Print Network [OSTI]

of operations. Whenever a metric is underperforming, links appear that take the user to other displays, such as corrective action, operating procedures, and diagnostic tools. Summary data from area-based SMARTboards can be linked into a site display for plant...

Jagen, P. R.

2008-01-01T23:59:59.000Z

286

Sandia National Laboratories: swirl ratio  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1developmentturbineredox-activeNational Solar Thermalsslsstudy ofphotovoltaics

287

Eccentric crank variable compression ratio mechanism  

DOE Patents [OSTI]

A variable compression ratio mechanism for an internal combustion engine that has an engine block and a crankshaft is disclosed. The variable compression ratio mechanism has a plurality of eccentric disks configured to support the crankshaft. Each of the plurality of eccentric disks has at least one cylindrical portion annularly surrounded by the engine block. The variable compression ratio mechanism also has at least one actuator configured to rotate the plurality of eccentric disks.

Lawrence, Keith Edward (Kobe, JP); Moser, William Elliott (Peoria, IL); Roozenboom, Stephan Donald (Washington, IL); Knox, Kevin Jay (Peoria, IL)

2008-05-13T23:59:59.000Z

288

Abundance Ratios in Early-Type Galaxies  

E-Print Network [OSTI]

Although evidence is accumulating that abundance ratios in galaxies are often non-solar, they are far from understood. I resume the current evidence for non-solar abundance ratios, supplementing the recent review by Worthey (1998) with some new results. It appears that the Mg/Fe abundance ratio only depends on the mass of the galaxy, not on the formation time-scale. For massive galaxies [Mg/Fe] > 0, while small galaxies show solar abundance ratios. Information about abundances of other element is scarce, but new evidence is given that [Ca/Fe] is solar, or slightly lower than solar, contrary to what is expected for an alpha-element.

Reynier Peletier

1999-04-21T23:59:59.000Z

289

American Recovery and Reinvestment Act Federal Energy Management Program Technical Assistance Project 244 US Coast Guard – Eastern Region  

SciTech Connect (OSTI)

This report documents the activities of a resource efficiency manager that served the US Coast Guard Eastern Region from November 23, 2009 through August 3, 2010.

Sandusky, William F.

2010-09-30T23:59:59.000Z

290

American Recovery and Reinvestment Act (ARRA) Federal Energy Management Program Technical Assistance Project 279 IMCOM-Southeast Region: Redstone Arsenal  

SciTech Connect (OSTI)

Report describing a building retuning workshop presented to staff at Redstone Arsenal. Document includes issues identified during building audits and recommendations for future activities to reduce energy use at the site.

Hatley, Darrel D.; Goddard, James K.

2010-09-30T23:59:59.000Z

291

Effect of Compression Ratio and Piston Geometry on RCCI load...  

Broader source: Energy.gov (indexed) [DOE]

Compression Ratio and Piston Geometry on RCCI load limit Effect of Compression Ratio and Piston Geometry on RCCI load limit Explores the effect of compression ratio and piston...

292

8, 41994219, 2008 Study of the ratios  

E-Print Network [OSTI]

(UV) spectra of atmospheric global irradiance with the miniature fiber optic spectrometer AvaSpec-256ACPD 8, 4199­4219, 2008 Study of the ratios UV-A/UV-B from UV irradiance spectra I. Ansko et al@aai.ee) 4199 #12;ACPD 8, 4199­4219, 2008 Study of the ratios UV-A/UV-B from UV irradiance spectra I. Ansko et

Boyer, Edmond

293

Active Energy-Aware Management of Business-Process Based Applications  

E-Print Network [OSTI]

Active Energy-Aware Management of Business-Process Based Applications Position Paper Danilo Ardagna Elettronica e Informazione, Italy lastname@elet.polimi.it Abstract. Energy management is becoming a priority in the design and operation of complex service-based information systems, as the energy costs

Becker, Steffen

294

Incorporating Drivability Metrics into Optimal Energy Management Strategies for Hybrid Vehicles Part 2: Real-World Robustness and  

E-Print Network [OSTI]

on government test cycles, and there are few results that compare optimal control algorithms to the controllers constraints on drivetrain activity while minimizing fuel consumption. Part 1 described the problem formulation, models, and simulation results on government test cycles for a prototype vehicle. In Part 2, controllers

Grizzle, Jessy W.

295

Physical Activity and Modernization among Bolivian Amerindians  

E-Print Network [OSTI]

analyze physical activity patterns among the Tsimane, forager-horticulturalists of Amazonian Bolivia on physical activity ratio (PAR), the ratio of total energy expenditure to basal metabolic rate. Accelerometry

Gurven, Michael

296

Fission Product Ratios as Treaty Monitoring Discriminants  

SciTech Connect (OSTI)

The International Monitoring System (IMS) of the Comprehensive Test Ban Treaty Organization (CTBTO) is currently under construction. The IMS is intended for monitoring of nuclear explosions. The radionuclide branch of the IMS monitors the atmosphere for short-lived radioisotopes indicative of a nuclear weapon test, and includes field collection and measurement stations, as well as laboratories to provide reanalysis of the most important samples and a quality control function. The Pacific Northwest National Laboratory in Richland, Washington hosts the United States IMS laboratory, with the designation “RL16.” Since acute reactor containment failures and chronic reactor leakage may also produce similar isotopes, it is tempting to compute ratios of detected isotopes to determine the relevance of an event to the treaty or agreement in question. In this paper we will note several shortcomings of simple isotopic ratios: (1) fractionation of different chemical species, (2) difficulty in comparing isotopes within a single element, (3) the effect of unknown decay times. While these shortcomings will be shown in the light of an aerosol sample, several of the problems extend to xenon isotopic ratios. The result of the difficulties listed above is that considerable human expertise will be required to convert a simple mathematical ratio into a criterion which will reliably categorize an event as ‘reactor’ or ‘weapon’.

Miley, Harry S.; Bowyer, Ted W.; Greenwood, Lawrence R.; Arthur, Richard J.

2008-05-15T23:59:59.000Z

297

Blowing Ratio Effects on Film Cooling Effectiveness  

E-Print Network [OSTI]

The research focuses on testing the film cooling effectiveness on a gas turbine blade suction side surface. The test is performed on a five bladed cascade with a blow down facility. Four different blowing ratios are used in this study, which are 0...

Liu, Kuo-Chun

2010-01-14T23:59:59.000Z

298

Reduce Building Energy Consumption by Improving the Supply Air Temperature Schedule and Recommissioning the Terminal Boxes, Submitted to the Energy Management and Operations Division at the M.D. Anderson Cancer Center  

E-Print Network [OSTI]

At the request of the Energy Management and Operations Department at M.D. Anderson Cancer Center, the Energy Systems Laboratory of Texas A&M University performed a study of optimizing the HVAC operation at its Basic Research Building. The Basic...

Liu, M.; Athar, A.; Zhu, Y.; Claridge, D. E.

1995-01-01T23:59:59.000Z

299

aspect ratio tori: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

300

aspect ratio su-8: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

air-fuel ratio: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

was performed to investigate the effects of air-fuel ratio, inlet boost pressure, hydrogen rich fuel reformate, and compression ratio on engine knock behavior. For each...

302

Two-Stage Variable Compression Ratio (VCR) System to Increase...  

Broader source: Energy.gov (indexed) [DOE]

Two-Stage Variable Compression Ratio (VCR) System to Increase Efficiency in Gasoline Powertrains Two-Stage Variable Compression Ratio (VCR) System to Increase Efficiency in...

303

Energy Balance Bowen Ratio Station (EBBR) Handbook  

SciTech Connect (OSTI)

The energy balance Bowen ratio (EBBR) system produces 30-minute estimates of the vertical fluxes of sensible and latent heat at the local surface. Flux estimates are calculated from observations of net radiation, soil surface heat flux, and the vertical gradients of temperature and relative humidity (RH). Meteorological data collected by the EBBR are used to calculate bulk aerodynamic fluxes, which are used in the Bulk Aerodynamic Technique (BA) EBBR value-added product (VAP) to replace sunrise and sunset spikes in the flux data. A unique aspect of the system is the automatic exchange mechanism (AEM), which helps to reduce errors from instrument offset drift.

Cook, DR

2011-02-23T23:59:59.000Z

304

Implications of Fast Reactor Transuranic Conversion Ratio  

SciTech Connect (OSTI)

Theoretically, the transuranic conversion ratio (CR), i.e. the transuranic production divided by transuranic destruction, in a fast reactor can range from near zero to about 1.9, which is the average neutron yield from Pu239 minus 1. In practice, the possible range will be somewhat less. We have studied the implications of transuranic conversion ratio of 0.0 to 1.7 using the fresh and discharge fuel compositions calculated elsewhere. The corresponding fissile breeding ratio ranges from 0.2 to 1.6. The cases below CR=1 (“burners”) do not have blankets; the cases above CR=1 (“breeders”) have breeding blankets. The burnup was allowed to float while holding the maximum fluence to the cladding constant. We graph the fuel burnup and composition change. As a function of transuranic conversion ratio, we calculate and graph the heat, gamma, and neutron emission of fresh fuel; whether the material is “attractive” for direct weapon use using published criteria; the uranium utilization and rate of consumption of natural uranium; and the long-term radiotoxicity after fuel discharge. For context, other cases and analyses are included, primarily once-through light water reactor (LWR) uranium oxide fuel at 51 MWth-day/kg-iHM burnup (UOX-51). For CR<1, the heat, gamma, and neutron emission increase as material is recycled. The uranium utilization is at or below 1%, just as it is in thermal reactors as both types of reactors require continuing fissile support. For CR>1, heat, gamma, and neutron emission decrease with recycling. The uranium utilization exceeds 1%, especially as all the transuranic elements are recycled. exceeds 1%, especially as all the transuranic elements are recycled. At the system equilibrium, heat and gamma vary by somewhat over an order of magnitude as a function of CR. Isotopes that dominate heat and gamma emission are scattered throughout the actinide chain, so the modest impact of CR is unsurprising. Neutron emitters are preferentially found among the higher actinides, so the neutron emission varies much stronger with CR, about three orders of magnitude.

Steven J. Piet; Edward A. Hoffman; Samuel E. Bays

2010-11-01T23:59:59.000Z

305

High aspect ratio, remote controlled pumping assembly  

DOE Patents [OSTI]

A miniature dual syringe-type pump assembly is described which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor. 4 figs.

Brown, S.B.; Milanovich, F.P.

1995-11-14T23:59:59.000Z

306

Meteorological Effects on Air/Fuel Ratio  

E-Print Network [OSTI]

1. "Temperature Compensat d Air/Fuel Ratio Control on a Recuperated Furnace," by J. L. Ferri. GTE Products Corporation, Towanda, PA, lECTC '83 2. Chemical Engineers Handbook, PerTY and Chilton, 5th ed.., (McGraw Hlln, p. 12-7. 3. "Technology..., E = (100 ... 10) (ill) - 100 = 17.2% excess a . 2 Example 2 A furnace uses recuperators which prehe~t the combustion air to 1200 OF using 30 OF air. WithJlOO OF air, the preheated air temperature will be approxIjrnately 1270 OF, a 70 OF increase...

Ferri, J. L.

1984-01-01T23:59:59.000Z

307

Variable Compression Ratio Engine | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of EnergyTheTwoVulnerabilities | Department of|VTA,anCompression Ratio

308

Hydraulic system for a ratio change transmission  

DOE Patents [OSTI]

Disclosed is a drive assembly (10) for an electrically powered vehicle (12). The assembly includes a transaxle (16) having a two-speed transmission (40) and a drive axle differential (46) disposed in a unitary housing assembly (38), an oil-cooled prime mover or electric motor (14) for driving the transmission input shaft (42), an adapter assembly (24) for supporting the prime mover on the transaxle housing assembly, and a hydraulic system (172) providing pressurized oil flow for cooling and lubricating the electric motor and transaxle and for operating a clutch (84) and a brake (86) in the transmission to shift between the two-speed ratios of the transmission. The adapter assembly allows the prime mover to be supported in several positions on the transaxle housing. The brake is spring-applied and locks the transmission in its low-speed ratio should the hydraulic system fail. The hydraulic system pump is driven by an electric motor (212) independent of the prime mover and transaxle.

Kalns, Ilmars (Northville, MI)

1981-01-01T23:59:59.000Z

309

Ratios of heavy hadron semileptonic decay rates  

E-Print Network [OSTI]

Ratios of charmed meson and baryon semileptonic decay rates appear to be satisfactorily described by considering only the lowest-lying (S-wave) hadronic final states and assuming the kinematic factor describing phase space suppression is the same as that for free quarks. For example, the rate for $D_s$ semileptonic decay is known to be $(17.0 \\pm 5.3)%$ lower than those for $D^0$ or $D^+$, and the model accounts for this difference. When applied to hadrons containing $b$ quarks, this method implies that the $B_s$ semileptonic decay rate is about 1% higher than that of the nonstrange $B$ mesons. This small difference thus suggests surprisingly good local quark-hadron duality for $B$ semileptonic decays, complementing the expectation based on inclusive quark-hadron duality that these differences in rates should not exceed a few tenths of a percent. For $\\Lambda_b$ semileptonic decay, however, the inclusive rate is predicted to be about 13% greater than that of the nonstrange $B$ mesons. This value, representing a considerable departure from a calculation using a heavy quark expansion, is close to the corresponding experimental ratio $\\Gamma(\\Lambda_b)/ \\bar \\Gamma(B) = 1.13 \\pm 0.03$ of total decay rates.

Michael Gronau; Jonathan L. Rosner

2010-12-27T23:59:59.000Z

310

Flexible Conversion Ratio Fast Reactor Systems Evaluation  

SciTech Connect (OSTI)

Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores reated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcme the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better themal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor.

Neil Todreas; Pavel Hejzlar

2008-06-30T23:59:59.000Z

311

Deere & Company Energy Management Program  

E-Print Network [OSTI]

for evaluating each unit's ene~gy savings techniques. Two more key elements merit attention. These are "energy ethic" and "feedback". The people that comprise a company can enhance a conservation program if they are convinced it is for their good as well... vital but "good business" as well. Meet Lester! One of our factories has had an an:i mated movie produced which ~eatures a polar bear: hero. He represents the central theme of an ene~gy conservation awareness program. The program con~ tinues...

Darby, D. F.

1981-01-01T23:59:59.000Z

312

ACC100 Crash Energy Management  

Broader source: Energy.gov (indexed) [DOE]

Design Multi-scale Design System developed at Rensselaer Comparison of the multiscale simulation and experimental results for circular tube made of 60 o braid architecture in...

313

ENERGY MANAGEMENT OPERATIONAL PROCEDURE MANUAL  

E-Print Network [OSTI]

...................................................................................4 Appendix A ­ Normal Heating Hours .........................................................10 Appendix E - Electric Fires. Responsibilities Estates Services: are responsible for the provision of Energy and Water Management systems

Harman, Neal.A.

314

Energy Management and Marketing Specialist  

Broader source: Energy.gov [DOE]

(See Frequently Asked Questions for more information). Where would I be working? Western Area Power Administration Sierra Nevada Region Power Marketing Merchant Real Time N6500 114 Parkshore Drive...

315

November 2013 Energy Management Report  

E-Print Network [OSTI]

for reducing its usage of electricity, gasoline, and natural gas: Energy consumption per gross square foot was achieved and surpassed. Total real energy consumption has decreased 25 percent over this same eleven grew by over 28 percent, from 18.5 million GSF to 23.7 million GSF. Energy consumption reduction

316

Merck Global Energy Management Program  

E-Print Network [OSTI]

automation system (BAS) management, insulation programs, employee awareness, and implementation of best practices. MERIT set an aggressive target of 3.5% savings over 2003 consumption and expects to achieve a 4.37 percent savings in 2004. The major... initiatives for 2004 include employee awareness, additional participation of non-manufacturing sites, minimization of capital investment on utility infrastructure, and implementation of energy best practices on all new projects. The original charter...

Williams, K.

2005-01-01T23:59:59.000Z

317

Energy Management Without a Staff  

E-Print Network [OSTI]

Energj Management Without a Staff David L. Dornbos, Sr. Manager, Facilities and "Energy Engineering Dept. Steelcase Inc. Grand Rapids, Michigan Our area assigned and central engineers are encouraged to design each project with energy... efficiency and cost as important objectives. It is their contribution to the process of problem solving, renovation, equipment installation, and construction. Recommendations are expected. The hands-on engineer is in the best position to provide...

Dornbos, D. L. Sr.

318

Energy Management in Olefins Units  

E-Print Network [OSTI]

to the point where waste heat from pyrolysis generates more than enough steam to power the olefins unit recovery section. Furthermore, incorporating gas turbine driven electrical generators or process compressors adds to the utility export potential of the unit...

Wells, T. A.

1982-01-01T23:59:59.000Z

319

In-House Energy Management  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

Establishes DOE requirements to meet or exceed laws, Executive Orders, and Federal regulations for energy efficiency, use of renewable energy, and water conservation at Federal facilities. Cancels DOE 4330.2D

1996-06-13T23:59:59.000Z

320

Energy Management Through Innovative Rates  

E-Print Network [OSTI]

of energy efficiency in the industrial sector and specific rate design alternatives for doing so....

Williams, M. L.

1982-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Energy Management at Deere & Company  

E-Print Network [OSTI]

that has become increasingly complex. Fuel availability is a fluctuating phenomenon. Technology to enable energy conservation and to supply efficient alternate non-depleting sources is complex. Government intervention is becoming increasingly pervasive...

Boyd, M. P.

1979-01-01T23:59:59.000Z

322

Federal Energy Management Success Stories  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAX POLICIES ANDIndustrialEnergy Federal Efficiency ProgramDepartment ofContact

323

Facilities Automation and Energy Management  

E-Print Network [OSTI]

capabilities can help pinpoint the equipment performance level and variations. The arithmetic and logic capabilities can be used to generate sophisticated and interactive control strategies. The communications capabilities provide management information...

Jen, D. P.

1983-01-01T23:59:59.000Z

324

Energy Management | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: TopEnergyIDIQBusinessin Jamaica,IdahoWyomingManagement for Motor-Driven

325

Role of an Energy Manager  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l LPROJECTS IN7 Roadmap for Bioenergy and Biobasedof EnergyRole of an

326

Abundance ratios in hierarchical galaxy formation  

E-Print Network [OSTI]

The chemical enrichment and stellar abundance ratios of galaxies which form in a hierarchical clustering scheme are calculated. For this purpose I adopt the star formation histories (SFH) as they are delivered by semi-analytic models in Kauffmann (1996}. It turns out that the average SFH of cluster ellipticals does not yield globally alpha-enhanced stellar populations. The star burst that occurs when the elliptical forms in the major merger plays therefore a crucial role in producing alpha-enhancement. Only under the assumption that the IMF is significantly flattened with respect to the Salpeter value during the burst, a Mg/Fe overabundant population can be obtained. In particular for the interpretation of radial gradients in metallicity and alpha-enhancement, the mixing of global and burst populations are of great importance. The model predicts bright field galaxies to be less alpha-enhanced than their counterparts in clusters.

D. Thomas

1999-01-18T23:59:59.000Z

327

Determination of Light Water Reactor Fuel Burnup with the Isotope Ratio Method  

SciTech Connect (OSTI)

For the current project to demonstrate that isotope ratio measurements can be extended to zirconium alloys used in LWR fuel assemblies we report new analyses on irradiated samples obtained from a reactor. Zirconium alloys are used for structural elements of fuel assemblies and for the fuel element cladding. This report covers new measurements done on irradiated and unirradiated zirconium alloys, Unirradiated zircaloy samples serve as reference samples and indicate starting values or natural values for the Ti isotope ratio measured. New measurements of irradiated samples include results for 3 samples provided by AREVA. New results indicate: 1. Titanium isotope ratios were measured again in unirradiated samples to obtain reference or starting values at the same time irradiated samples were analyzed. In particular, 49Ti/48Ti ratios were indistinguishably close to values determined several months earlier and to expected natural values. 2. 49Ti/48Ti ratios were measured in 3 irradiated samples thus far, and demonstrate marked departures from natural or initial ratios, well beyond analytical uncertainty, and the ratios vary with reported fluence values. The irradiated samples appear to have significant surface contamination or radiation damage which required more time for SIMS analyses. 3. Other activated impurity elements still limit the sample size for SIMS analysis of irradiated samples. The sub-samples chosen for SIMS analysis, although smaller than optimal, were still analyzed successfully without violating the conditions of the applicable Radiological Work Permit

Gerlach, David C.; Mitchell, Mark R.; Reid, Bruce D.; Gesh, Christopher J.; Hurley, David E.

2007-11-01T23:59:59.000Z

328

GLOBAL STABILITY STUDY OF THE ULTRALOW ASPECT RATIO TOKAMAK,  

E-Print Network [OSTI]

generated with aspect ratios as low as 1.1. In this extreme limit the transition of the spheromak (qedge= 0] is similar to the spheromak [5]in its strong paramagnetism and magnetic helical pitch. As the aspect ratio

329

Ultra-short nacelles for low fan pressure ratio propulsors  

E-Print Network [OSTI]

This thesis addresses the uncharted inlet and nacelle design space for low pressure ratio fans for advanced aeroengines. A key feature in low fan pressure ratio (FPR) propulsors with short inlets and nacelles is the increased ...

Peters, Andreas, Ph. D. Massachusetts Institute of Technology

2014-01-01T23:59:59.000Z

330

BUILDING EFFECTIVENESS COMMUNICATION RATIOS FOR IMPROVED BUILDING LIFE CYCLE MANAGEMENT  

E-Print Network [OSTI]

BUILDING EFFECTIVENESS COMMUNICATION RATIOS FOR IMPROVED BUILDING LIFE CYCLE MANAGEMENT Elmer building energy performance assessment frameworks, quantifying and categorising buildings post occupancy a performance-based strategy utilising building effectiveness communication ratios stored in Building

331

aerosol ratio program: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

contribute a major portion of atmospheric aerosol mass loading 5. The estimated global annual Liou, K. N. 2 Studying Clouds and Aerosols with Lidar Depolarization Ratio and...

332

Two-Stage Variable Compression Ratio (VCR) System to Increase...  

Broader source: Energy.gov (indexed) [DOE]

th , 2012 Two-Stage Variable Compression Ratio (VCR) System to Increase Efficiency in Gasoline Powertrains DEER Conference 2012 D. Tomazic, H. Kleeberg, S. Bowyer, FEV Inc. J....

333

Oxygen And Carbon Isotope Ratios Of Hydrothermal Minerals From...  

Open Energy Info (EERE)

boiling or by isotopic exchange at low waterrock ratios in new fractures. The mineralogy and apparent 18O enrichments of hydrothermal fracture-filling minerals are...

334

Estimation of (n,f) Cross-Sections by Measuring Reaction Probability Ratios  

SciTech Connect (OSTI)

Neutron-induced reaction cross-sections on unstable nuclei are inherently difficult to measure due to target activity and the low intensity of neutron beams. In an alternative approach, named the 'surrogate' technique, one measures the decay probability of the same compound nucleus produced using a stable beam on a stable target to estimate the neutron-induced reaction cross-section. As an extension of the surrogate method, in this paper they introduce a new technique of measuring the fission probabilities of two different compound nuclei as a ratio, which has the advantage of removing most of the systematic uncertainties. This method was benchmarked in this report by measuring the probability of deuteron-induced fission events in coincidence with protons, and forming the ratio P({sup 236}U(d,pf))/P({sup 238}U(d,pf)), which serves as a surrogate for the known cross-section ratio of {sup 236}U(n,f)/{sup 238}U(n,f). IN addition, the P({sup 238}U(d,d{prime}f))/P({sup 236}U(d,d{prime}f)) ratio as a surrogate for the {sup 237}U(n,f)/{sup 235}U(n,f) cross-section ratio was measured for the first time in an unprecedented range of excitation energies.

Plettner, C; Ai, H; Beausang, C W; Bernstein, L A; Ahle, L; Amro, H; Babilon, M; Burke, J T; Caggiano, J A; Casten, R F; Church, J A; Cooper, J R; Crider, B; Gurdal, G; Heinz, A; McCutchan, E A; Moody, K; Punyon, J A; Qian, J; Ressler, J J; Schiller, A; Williams, E; Younes, W

2005-04-21T23:59:59.000Z

335

241Am (n,gamma) isomer ratio measurement  

SciTech Connect (OSTI)

The objective of this project is to improve the accuracy of the {sup 242}Cm/{sup 241}Am radiochemistry ratio. We have performed an activation experiment to measure the {sup 241}Am(n,{gamma}) cross section leading to either the ground state of {sup 242g}Am (t{sub 1/2} = 16 hr) which decays to {sup 242}Cm (t{sub 1/2} = 163 d) or the long-lived isomer {sup 242m}Am (t{sub 1/2} = 141 yr). This experiment will develop a new set of americium cross section evaluations that can be used with a measured {sup 242}Cm/{sup 241}Am radiochemical measurement for nuclear forensic purposes. This measurement is necessary to interpret the {sup 242}Cm/{sup 241}Am ratio because a good measurement of this neutron capture isomer ratio for {sup 241}Am does not exist. The targets were prepared in 2007 from {sup 241}Am purified from LANL stocks. Gold was added to the purified {sup 241}Am as an internal neutron fluence monitor. These targets were placed into a holder, packaged, and shipped to Forschungszentrum Karlsruhe, where they were irradiated at their Van de Graff facility in February 2008. One target was irradiated with {approx}25 keV quasimonoenergetic neutrons produced by the {sup 7}Li(p,n) reaction for 3 days and a second target was also irradiated for 3 days with {approx}500 keV neutrons. Because it will be necessary to separate the {sup 242}Cm from the {sup 241}Am in order to measure the amount of {sup 242}Cm by alpha spectrometry, research into methods for americium/curium separations were conducted concurrently. We found that anion exchange chromatography in methanol/nitric acid solutions produced good separations that could be completed in one day resulting in a sample with no residue. The samples were returned from Germany in July 2009 and were counted by gamma spectrometry. Chemical separations have commenced on the blank sample. Each sample will be spiked with {sup 244}Cm, dissolved and digested in nitric acid solutions. One third of each sample will be processed at a time. First, the gold will be removed by anion exchange chromatography. Then the {sup 242}Cm will be separated from the {sup 241}Am using the methanol/nitric acid anion exchange method. When a sufficient separation has been achieved, a deposit will be prepared and the {sup 242}Cm will be counted by alpha spectrometry. The purified {sup 241}Am fraction containing the long lived {sup 242m}Am will be allowed to decay into {sup 242}Cm for a period of {approx}6 months. After this time, the americium/curium separations will be repeated and the {sup 242}Cm that has grown in will be counted by alpha spectrometry. At the conclusion of the experiment, we will have cross section measurements for {sup 241}Am (n,{gamma}) {sup 242g}Am and {sup 241}Am (n,V) {sup 242m}Am at two energies.

Bond, Evelyn M [Los Alamos National Laboratory; Vieira, David J [Los Alamos National Laboratory; Moody, Walter A [Los Alamos National Laboratory; Slemmons, Alice K [Los Alamos National Laboratory

2011-01-05T23:59:59.000Z

336

IEA Workshop 59 Shape and Aspect Ratio Optimization for  

E-Print Network [OSTI]

IEA Workshop 59 Shape and Aspect Ratio Optimization for High Beta, Steady-State Tokamak SCOPE and aspect ratio is particularly important for achieving high beta and also for the optimization of edge optimization of high beta steady state tokamak including DEMO concept, stability and CD assessment

337

Prominence seismology using the period ratio of transverse thread oscillations  

E-Print Network [OSTI]

The ratio of the period of the fundamental mode to that of the first overtone of kink oscillations, from here on the "period ratio", is a seismology tool that can be used to infer information about the spatial variation of density along solar magnetic flux tubes. The period ratio is 2 in longitudinally homogeneous thin tubes, but it differs from 2 due to longitudinal inhomogeneity. In this paper we investigate the period ratio in longitudinally inhomogeneous prominence threads and explore its implications for prominence seismology. We numerically solve the two-dimensional eigenvalue problem of kink oscillations in a model of a prominence thread. We take into account three nonuniform density profiles along the thread. In agreement with previous works that used simple piecewise constant density profiles, we find that the period ratio is larger than 2 in prominence threads. When the ratio of the central density to that at the footpoints is fixed, the period ratio depends strongly on the form of the density profi...

Soler, R; Ballester, J L

2015-01-01T23:59:59.000Z

338

Rapid Replication of High Aspect Ratio Molds for UV Embossing  

E-Print Network [OSTI]

This paper describes a promising fabrication technique for rapid replication of high aspect ratio microstructured molds for UV embossing. The process involves casting silicone rubber on a microstructured master, replicating ...

Yan, Yehai

339

The Ne/O abundance ratio in the quiet Sun  

E-Print Network [OSTI]

Aims: To determine the neon-to-oxygen abundance in the quiet Sun, a proxy for the photospheric abundance ratio. Method: An emission measure method applied to extreme ultraviolet emission lines of Ne IV-VI and O III-V ions observed by the Coronal Diagnostic Spectrometer on the SOHO satellite. Results: The average Ne/O abundance ratio in supergranule cell centre regions is 0.18 +/- 0.05, while in supergranule network regions is 0.16 +/- 0.04. A photospheric Ne/O ratio of 0.17 +/- 0.05 is suggested, in good agreement with the most recent compilation of solar photospheric abundances, but discrepant with a recent Ne/O ratio derived from stellar X-ray spectra and revised neon abundances suggested from solar interior models.

P. R. Young

2005-10-10T23:59:59.000Z

340

Chloride-Magnesium Ratio of Shallow Groundwaters as a Regional...  

Open Energy Info (EERE)

Chloride-Magnesium Ratio of Shallow Groundwaters as a Regional Geothermal Indicator in Hawaii Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article:...

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

aspect ratio silicon: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

silicon-nitride hard-mask for high aspect-ratio silicon fins V. Jovanovi, S, Zagreb, Croatia Abstract - A method for using hard-masks to achieve sub- 100 nm patterning of...

342

Separated Response Function Ratios in Exclusive, Forward ?[superscript ±] Electroproduction  

E-Print Network [OSTI]

The study of exclusive ?[superscript ±] electroproduction on the nucleon, including separation of the various structure functions, is of interest for a number of reasons. The ratio R[subscript L] = ?[?? over L]/?[?+ over ...

Huber, G.?M.

343

Interpretation of the atmospheric muon charge ratio in MINOS  

E-Print Network [OSTI]

MINOS is the first large magnetic detector deep underground and is the first to measure the muon charge ratio with high statistics in the region near 1 TeV.\\cite{bib:adamson} An approximate formula for the muon charge ratio can be expressed in terms of $\\epsilon_\\pi$ = 115 GeV, $\\epsilon_K$ = 850 GeV and $\\ec$. The implications for K production in the atmosphere will be discussed.

Philip Schreiner; Maury Goodman

2007-06-04T23:59:59.000Z

344

The E2/M1 ratio in {Delta} photoproduction  

SciTech Connect (OSTI)

New high-precision measurements of p({rvec {gamma}}, {pi}) and p({rvec {gamma}}, {gamma}) cross sections and beam asymmetries have been combined with other polarization ratios in a simultaneous analysis of both reactions. The E2/M1 mixing ratio for the n {r_arrow} {Delta} transition extracted from this analysis is EMR = {minus}3.0% {+-} 0.3 (stat+sys) {+-} 0.2 (model).

Hoblit, S. [Brookhaven National Lab., Upton, NY (United States). Physics Dept.]|[Univ. of Virginia, Charlottesville, VA (United States). Dept. of Physics; Blanpied, G. [Univ. of South Carolina, Columbia, SC (United States). Dept. of Physics; Blecher, M. [Virginia Polytechnic Inst. and State Univ., Blacksburg, VA (United States). Physics Dept.] [and others; LEGS Collaboration

1997-10-01T23:59:59.000Z

345

System and method for high precision isotope ratio destructive analysis  

DOE Patents [OSTI]

A system and process are disclosed that provide high accuracy and high precision destructive analysis measurements for isotope ratio determination of relative isotope abundance distributions in liquids, solids, and particulate samples. The invention utilizes a collinear probe beam to interrogate a laser ablated plume. This invention provides enhanced single-shot detection sensitivity approaching the femtogram range, and isotope ratios that can be determined at approximately 1% or better precision and accuracy (relative standard deviation).

Bushaw, Bruce A; Anheier, Norman C; Phillips, Jon R

2013-07-02T23:59:59.000Z

346

EV-Smart Grid Research & Interoperability Activities  

Broader source: Energy.gov (indexed) [DOE]

isolation chamber w wireless charging test fixture Integrated grid simulation, real-time grid data, and configurable branch circuit for smart charging and energy management...

347

Measurement of the /sup 129/I//sup 131/I ratio in Chernobyl fallout  

SciTech Connect (OSTI)

Rainwater collected in the Munich area approximately one week after the Chernobyl reactor accident was investigated for its content of the radioisotopes /sup 129/I (T/sub 1/2/ = 1.6 x 10/sup 7/ y) and /sup 131/I (T/sub 1/2/ = 8.04 d). For the time of release, an isotopic ratio of /sup 129/I//sup 131/I = 19 +- 5 was found. This value was obtained from a gamma-ray activity measurement of /sup 131/I with a GE detector and a concentration measurement of /sup 129/I with accelerator mass spectrometry. From the measured ratio an operating time of the reactor prior to the accident in the vicinity of two years can be estimated, which is in fair agreement with estimates from other long-lived to short-lived radioisotope ratios in the Chernobyl fallout. Some measurements of /sup 131/I activity in thyroids of persons living in the Munich area is also reported.

Kutschera, W.; Fink, D.; Paul, M.; Hollos, G.; Kaufman, A.

1986-01-01T23:59:59.000Z

348

The Superior Energy Performance program, administered by DOE, certifies industrial facilities that implement an ISO 50001 compliant energy management system and achieve improved energy performance.  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up from theDepartment of EnergyThe Sun and Its Energy (11 activities) The Sun and Its

349

Half-life and gamma abundance ratio measurements of Sm-153  

SciTech Connect (OSTI)

The measurement of the decay of 153Sm was observed by gamma spectrometry, liquid scintillation counting and gas proportional counting in an attempt to confirm the half life and gamma abundance ratios for this isotope. Recent changes in the published nuclear decay data indicate that historical literature values may be biased. The 153Sm was made by the neutron activation of ultrapure isotopically enriched 152Sm to create 153Sm. The decay measurements were made over a three week period and no other isotopes were detected during this time. The gamma abundance ratio for the 103 keV gamma was measured to be (27.9%) which is 4% lower than the published data. In addition, the half life was 1.9308 days, which is 0.34% lower than the published data.

Friese, Judah I.; Payne, Rosara F.; Greenwood, Lawrence R.; Soderquist, Chuck Z.; Garofoli, Stephanie J.

2009-11-02T23:59:59.000Z

350

Energy-efficiency testing activities of the Mobile Energy Laboratory  

SciTech Connect (OSTI)

This report summarizes energy-efficiency testing activities during the first and second quarters of fiscal year 1990 applying the Mobile Energy Laboratory (MEL) testing capabilities. Four MELs, developed by the US Department of Energy (DOE) Federal Energy Management Program (FEMP), are administered by Pacific Northwest Laboratory (PNL) for energy testing and program support functions at federal facilities. The using agencies principally fund MEL applications, while DOE/FEMP funds program administration and capability enhancement activities. This report fulfills the requirements established in the MEL Use Plan (PNL-6861) for semiannual reporting on energy-efficiency testing activities using the MEL capabilities. The MEL Use Committee, formally established in 1989, developed the MEL Use Plan and meets semiannually to establish priorities for energy-efficient testing applications using the MEL capabilities.

Parker, G.B.

1991-01-01T23:59:59.000Z

351

Solar load ratio method applied to commercial building active solar system sizing  

SciTech Connect (OSTI)

The hourly simulation procedure is the DOE-2 building energy analysis computer program. It is capable of calculating the loads and of simulating various control strategies in detail for both residential and commercial buildings and yet is computationally efficient enough to be used for extensive parametric studies. In addition, to a Building Service Hot Water (BSHW) System and a combined space heating and hot water system using liquid collectors for a commercial building analyzed previously, a space heating system using an air collector is analyzed. A series of runs is made for systems using evacuated tube collectors for comparison to flat-plate collectors, and the effects of additional system design parameters are investigated. Also, the generic collector types are characterized by standard efficiency curves, rather than by detailed collector specifications. (MHR)

Schnurr, N.M.; Hunn, B.D.; Williamson, K.D. III

1981-01-01T23:59:59.000Z

352

Ratio of Pion Kaon Production in Proton Carbon Interactions  

SciTech Connect (OSTI)

The ratio of pion-kaon production by 120 GeV/c protons incident on carbon target is presented. The data was recorded with the Main Injector Particle Production experiment at Fermi National Accelerator Laboratory. Production ratios of K{sup +}/{pi}{sup +}, K{sup -}/{pi}{sup -}, K{sup -}/K{sup +}, and {pi}{sup -}/{pi}{sup +} are measured in 24 bins in longitudinal momentum from 20 to 90 GeV/c and transverse momentum up to 2 GeV/c. The measurement is compared to existing data sets, particle production Monte Carlo results from FLUKA-06, parametrization of proton-beryllium data at 400/450 GeV/c, and ratios measured by the MINOS experiment on the NuMI target.

Lebedev, Andrey V.; /Harvard U.

2007-05-01T23:59:59.000Z

353

Estimate of the triton asymptotic D to S ratio  

SciTech Connect (OSTI)

The role of the deuteron asymptotic D to S normalization ratio eta/sup d/ in the calculation of triton observables is emphasized both within a simple model and in an exact numerical calculation. We suggest a new correlation among eta/sup t//eta/sup d/ and E/sub t/ in dynamical three nucleon calculations, where eta/sup t/ is the triton asymptotic D to S ratio and E/sub t/ is the triton binding energy. Studying this correlation we obtained eta/sup t//eta/sup d/ = 1.68 +- 0.04. .AE

Frederico, T.; Adhikari, S.K.; Hussein, M.S.

1988-01-01T23:59:59.000Z

354

"Code(a)","Energy-Management Activity","No Participation","Participation(b)","In-house","Other","Don't Know"  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 10 MECSPropaneResidential"Total" "(Data051.3241

355

"NAICS Code(a)","Energy-Management Activity","No Participation","Participation(b)","Don't Know","Not Applicable"  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 10 MECSPropaneResidential"Total"2.4 Relative4B WinterA.1.4

356

A Link Between Black Holes and the Golden Ratio  

E-Print Network [OSTI]

We consider a variational formalism to describe black holes solution in higher dimensions. Our procedure clarifies the arbitrariness of the radius parameter and, in particular, the meaning of the event horizon of a black hole. Moreover, our formalism enables us to find a surprising link between black holes and the golden ratio.

J. A. Nieto

2011-06-02T23:59:59.000Z

357

aerosol ratio test: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

aerosol ratio test First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Effect of mineral dust aerosol...

358

A genetically encoded fluorescent reporter of ATP:ADP ratio  

E-Print Network [OSTI]

A genetically encoded fluorescent reporter of ATP:ADP ratio Jim Berg1,2, Yin Pun Hung1 & Gary's affinity for Mg-ATP was o100 nM, as seen for other members of the bacterial PII regulator family, a surprisingly high affinity given that normal intracellular ATP concentration is in the millimolar range. ADP

Yellen, Gary

359

Generalized solar load ratio correlation for direct gain buildings  

SciTech Connect (OSTI)

A generalized solar load ratio correlation has been developed for direct gain buildings by generating relationships between the correlation parameters and two fundamental design parameters. The first design parameter is the steady state conductance of the solar aperture, U/sub c/. The second is the effective heat capacity of the solar zone, EHC.

Wray, W.O.; Best, E.D.

1986-01-01T23:59:59.000Z

360

Improved Signal-to-Noise Ratio Estimation for Speech Enhancement  

E-Print Network [OSTI]

1 Improved Signal-to-Noise Ratio Estimation for Speech Enhancement Cyril Plapous, Member, IEEE speech enhancement in noisy environments. State-of- the-art short-time noise reduction techniques reduction techniques, includ- ing TSNR, introduce harmonic distortion in enhanced speech because

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Net energy ratio of photobiohydrogen generation G. Burgessa  

E-Print Network [OSTI]

of standard theory for tubular solar collectors. Small diameter reactors have a low NER as the mixing energyNet energy ratio of photobiohydrogen generation G. Burgessa and J.G. Fernández National University Canberra ACT 0200, AUSTRALIA E-mail: greg.burgess@anu.edu.au Abstract: We estimate

362

Prediction-Based Compression Ratio Boundaries for Medical Images  

E-Print Network [OSTI]

Prediction-Based Compression Ratio Boundaries for Medical Images Xiaojun Qi Computer Science present prediction-based image compression techniques take advantage of either intra- or inter function. The prediction-based compression technique has been applied on some magnetic resonance (MR) brain

Qi, Xiaojun

363

Magnesium Isotope Ratios in omega Centauri Red Giants  

E-Print Network [OSTI]

We have used high resolution observations obtained at the AAT with UHRF (R ~ 100,000) and at Gemini-S with b-HROS (R ~ 150,000) to determine magnesium isotope ratios for seven omega Centauri red giants that cover a range in iron abundance from [Fe/H] = --1.78 to --0.78 dex, and for two red giants in M4 (NGC 6121). The omega Centauri stars sample both the "primordial" (i.e., O-rich, Na and Al-poor) and the "extreme" (O-depleted, Na and Al-rich) populations in the cluster. The primordial population stars in both omega Centauri and M4 show (25Mg, 26Mg)/24 Mg isotopic ratios that are consistent with those found for the primordial population in other globular clusters with similar [Fe/H] values. The isotopic ratios for the omega Centauri extreme stars are also consistent with those for extreme population stars in other clusters. The results for the extreme population stars studied indicate that the 26Mg/24Mg ratio is highest at intermediate metallicities ([Fe/H] < --1.4 dex), and for the highest [Al/Fe] values....

Da Costa, G S; Yong, David

2013-01-01T23:59:59.000Z

364

Design studies of low aspect ratio quasi-omnigenous stellarators  

E-Print Network [OSTI]

optimization principles for the design of a more attractive reactor. These are 3 and 4 field period low aspect ratio quasi-omnigenous stellarators based on an optimization method that aims at improved confinement stability boundaries. 1. Configuration optimization The development of increasingly sophisticated

Martín-Solís, José Ramón

365

Holographic study of conventional and negative Poisson's ratio metallic foams  

E-Print Network [OSTI]

. Inhomogeneous, non-affine deformation was observed holographically in both foam materials. Introduction in this series were determined from displacement measurements of high magnification video tapes of the tensile a very useful and reliable tool to determine the Poisson's ratio of orthotropic FRP (Fiber Reinforced

Lakes, Roderic

366

Allowable pillar to diameter ratio for strategic petroleum reserve caverns.  

SciTech Connect (OSTI)

This report compiles 3-D finite element analyses performed to evaluate the stability of Strategic Petroleum Reserve (SPR) caverns over multiple leach cycles. When oil is withdrawn from a cavern in salt using freshwater, the cavern enlarges. As a result, the pillar separating caverns in the SPR fields is reduced over time due to usage of the reserve. The enlarged cavern diameters and smaller pillars reduce underground stability. Advances in geomechanics modeling enable the allowable pillar to diameter ratio (P/D) to be defined. Prior to such modeling capabilities, the allowable P/D was established as 1.78 based on some very limited experience in other cavern fields. While appropriate for 1980, the ratio conservatively limits the allowable number of oil drawdowns and hence limits the overall utility and life of the SPR cavern field. Analyses from all four cavern fields are evaluated along with operating experience gained over the past 30 years to define a new P/D for the reserve. A new ratio of 1.0 is recommended. This ratio is applicable only to existing SPR caverns.

Ehgartner, Brian L.; Park, Byoung Yoon

2011-05-01T23:59:59.000Z

367

Negative Poisson's Ratio Behavior Induced by an Elastic Instability  

E-Print Network [OSTI]

's ratio, which is approximately 0.5 for rubber and 0.3 for glass and steel. Materials with a negative] prostheses,[3] piezocomposites with optimal performance[4] and foams with superior damping and acoustic foams with reentrant struc- tures,[1] hierarchical laminates,[12] polymeric and metallic foams,[13

Reis, Pedro Miguel

368

The Proton Form Factor Ratio Measurements at Jefferson Lab  

SciTech Connect (OSTI)

The ratio of the proton form factors, G{sub Ep}/G{sub Mp}, has been measured from Q{sup 2} of 0.5 GeV{sup 2} to 8.5 GeV{sup 2}, at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of the transverse and longitudinal polarization components of the recoiling proton in elastic electron-proton scattering. The discovery that the proton form factor ratio measured in these experiments decreases approximately linearly with four-momentum transfer, Q{sup 2}, for values above #25;~1 GeV{sup 2}, is one of the most significant results to come out of JLab. These results have had a large impact on progress in hadronic physics; and have required a significant rethinking of nucleon structure. The increasingly common use of the double-polarization technique to measure the nucleon form factors, in the last 15 years, has resulted in a dramatic improvement of the quality of all four nucleon electromagnetic form factors, G{sub Ep}, G{sub Mp}, G{sub En} and G{sub Mn}. There is an approved experiment at JLab, GEP(V), to continue the ratio measurements to 12 GeV{sup 2}. A dedicated experimental setup, the Super Bigbite Spectrometer (SBS), will be built for this purpose. It will be equipped with a focal plane polarimeter to measure the polarization of the recoil protons. The scattered electrons will be detected in an electromagnetic calorimeter. In this presentation, I will review the status of the proton elastic electromagnetic form factors and discuss a number of theoretical approaches to describe nucleon form factors.

Punjabi, Vina A. [Norfolk State University, Norfolk, VA (United States); Perdrisat, Charles F. [William and Mary College, Williamsburg, VA (United States)

2014-03-01T23:59:59.000Z

369

MAGNESIUM ISOTOPE RATIOS IN {omega} CENTAURI RED GIANTS  

SciTech Connect (OSTI)

We have used the high-resolution observations obtained at the Anglo-Australian Telescope with Ultra-High Resolution Facility (R {approx} 100,000) and at Gemini-S with b-HROS (R {approx} 150,000) to determine magnesium isotope ratios for seven {omega} Cen red giants that cover a range in iron abundance from [Fe/H] = -1.78 to -0.78 dex, and for two red giants in M4 (NGC 6121). The {omega} Cen stars sample both the ''primordial'' (i.e., O-rich, Na- and Al-poor) and the ''extreme'' (O-depleted, Na- and Al-rich) populations in the cluster. The primordial population stars in both {omega} Cen and M4 show ({sup 25}Mg, {sup 26}Mg)/{sup 24}Mg isotopic ratios that are consistent with those found for the primordial population in other globular clusters with similar [Fe/H] values. The isotopic ratios for the {omega} Cen extreme stars are also consistent with those for extreme population stars in other clusters. The results for the extreme population stars studied indicate that the {sup 26}Mg/{sup 24}Mg ratio is highest at intermediate metallicities ([Fe/H] < -1.4 dex), and for the highest [Al/Fe] values. Further, the relative abundance of {sup 26}Mg in the extreme population stars is notably higher than that of {sup 25}Mg, in contrast to model predictions. The {sup 25}Mg/{sup 24}Mg isotopic ratio in fact does not show any obvious dependence on either [Fe/H] or [Al/Fe] nor, intriguingly, any obvious difference between the primordial and extreme population stars.

Da Costa, G. S.; Norris, John E.; Yong, David [Research School of Astronomy and Astrophysics, Australian National University, Canberra, ACT 0200 (Australia)

2013-05-20T23:59:59.000Z

370

Ratios of Helicity Amplitudes for Exclusive rho-0 Electroproduction  

E-Print Network [OSTI]

Exclusive rho^0-meson electroproduction is studied in the HERMES experiment, using a 27.6 GeV longitudinally polarized electron/positron beam and unpolarized hydrogen and deuterium targets in the kinematic region 0.5 GeV^2 \\rho_T), T_{01} (\\gamma^*_T --> \\rho_L), T_{10} (\\gamma^*_L --> \\rho_T), and T_{1-1} (\\gamma^*_{-T} -->\\rho_T) to T_{00} (\\gamma^*_L --> \\rho_L) are extracted from the data. For the unnatural-parity-exchange amplitude U_{11}, the ratio |U_{11}/T_{00}| is obtained. The Q^2 and t' dependences of these ratios are presented and compared with perturbative QCD predictions.

Airapetian, A; Akopov, Z; Aschenauer, E C; Augustyniak, W; Avakian, R; Avetissian, A; Avetisyan, E; Belostotski, S; Bianchi, N; Blok, H P; Borissov, A; Bowles, J; Bryzgalov, V; Burns, J; Capiluppi, M; Capitani, G P; Cisbani, E; Ciullo, G; Contalbrigo, M; Dalpiaz, P F; Deconinck, W; De Leo, R; De Nardo, L; De Sanctis, E; Diefenthaler, M; Di Nezza, P; Dueren, M; Ehrenfried, M; Elbakian, G; Ellinghaus, F; Fabbri, R; Fantoni, A; Felawka, L; Frullani, S; Gabbert, D; Gapienko, G; Gapienko, V; Garibaldi, F; Gavrilov, G; Gharibyan, V; Giordano, F; Gliske, S; Golembiovskaya, M; Hadjidakis, C; Hartig, M; Hasch, D; Hill, G; Hillenbrand, A; Hoek, M; Holler, Y; Hristova, I; Imazu, Y; Ivanilov, A; Jackson, H E; Jo, H S; Joosten, S; Kaiser, R; Karyan, G; Keri, T; Kinney, E; Kisselev, A; Kobayashi, N; Korotkov, V; Kozlov, V; Kravchenko, P; Krivokhijine, V G; Lagamba, L; Lamb, R; Lapikas, L; Lehmann, I; Lenisa, P; Linden-Levy, L A; Ruiz, A Lopez; Lorenzon, W; Lu, X -G; Lu, X -R; Ma, B -Q; Mahon, D; Makins, N C R; Manaenkov, S I; Manfre, L; Mao, Y; Marianski, B; de la Ossa, A Martinez; Marukyan, H; Miller, C A; Miyachi, Y; Movsisyan, A; Muccifora, V; Murray, M; Mussgiller, A; Nappi, E; Naryshkin, Y; Nass, A; Negodaev, M; Nowak, W -D; Pappalardo, L L; Perez-Benito, R; Pickert, N; Reimer, P E; Reolon, A R; Riedl, C; Rith, K; Rosner, G; Rostomyan, A; Rubin, J; Ryckbosch, D; Salomatin, Y; Sanftl, F; Schaefer, A; Schnell, G; Schueler, K P; Seitz, B; Shibata, T -A; Shutov, V; Stancari, M; Statera, M; Steffens, E; Steijger, J J M; Stinzing, F; Taroian, S; Terkulov, A; Trzcinski, A; Tytgat, M; Vandenbroucke, A; Van Haarlem, Y; Van Hulse, C; Veretennikov, D; Vikhrov, V; Vilardi, I; Wang, S; Yaschenko, S; Yen, S; Yu, W; Zihlmann, B; Zupranski, P

2010-01-01T23:59:59.000Z

371

Ratios of Helicity Amplitudes for Exclusive rho-0 Electroproduction  

E-Print Network [OSTI]

Exclusive rho^0-meson electroproduction is studied in the HERMES experiment, using a 27.6 GeV longitudinally polarized electron/positron beam and unpolarized hydrogen and deuterium targets in the kinematic region 0.5 GeV^2 \\rho_T), T_{01} (\\gamma^*_T --> \\rho_L), T_{10} (\\gamma^*_L --> \\rho_T), and T_{1-1} (\\gamma^*_{-T} -->\\rho_T) to T_{00} (\\gamma^*_L --> \\rho_L) are extracted from the data. For the unnatural-parity-exchange amplitude U_{11}, the ratio |U_{11}/T_{00}| is obtained. The Q^2 and t' dependences of these ratios are presented and compared with perturbative QCD predictions.

The HERMES Collaboration; A. Airapetian; N. Akopov; Z. Akopov; E. C. Aschenauer; W. Augustyniak; R. Avakian; A. Avetissian; E. Avetisyan; S. Belostotski; N. Bianchi; H. P. Blok; A. Borissov; J. Bowles; V. Bryzgalov; J. Burns; M. Capiluppi; G. P. Capitani; E. Cisbani; G. Ciullo; M. Contalbrigo; P. F. Dalpiaz; W. Deconinck; R. De Leo; L. De Nardo; E. De Sanctis; M. Diefenthaler; P. Di Nezza; M. Dueren; M. Ehrenfried; G. Elbakian; F. Ellinghaus; R. Fabbri; A. Fantoni; L. Felawka; S. Frullani; D. Gabbert; G. Gapienko; V. Gapienko; F. Garibaldi; G. Gavrilov; V. Gharibyan; F. Giordano; S. Gliske; M. Golembiovskaya; C. Hadjidakis; M. Hartig; D. Hasch; G. Hill; A. Hillenbrand; M. Hoek; Y. Holler; I. Hristova; Y. Imazu; A. Ivanilov; H. E. Jackson; H. S. Jo; S. Joosten; R. Kaiser; G. Karyan; T. Keri; E. Kinney; A. Kisselev; N. Kobayashi; V. Korotkov; V. Kozlov; P. Kravchenko; V. G. Krivokhijine; L. Lagamba; R. Lamb; L. Lapikas; I. Lehmann; P. Lenisa; L. A. Linden-Levy; A. Lopez Ruiz; W. Lorenzon; X. -G. Lu; X. -R. Lu; B. -Q. Ma; D. Mahon; N. C. R. Makins; S. I. Manaenkov; L. Manfre; Y. Mao; B. Marianski; A. Martinez de la Ossa; H. Marukyan; C. A. Miller; Y. Miyachi; A. Movsisyan; V. Muccifora; M. Murray; A. Mussgiller; E. Nappi; Y. Naryshkin; A. Nass; M. Negodaev; W. -D. Nowak; L. L. Pappalardo; R. Perez-Benito; N. Pickert; P. E. Reimer; A. R. Reolon; C. Riedl; K. Rith; G. Rosner; A. Rostomyan; J. Rubin; D. Ryckbosch; Y. Salomatin; F. Sanftl; A. Schaefer; G. Schnell; K. P. Schueler; B. Seitz; T. -A. Shibata; V. Shutov; M. Stancari; M. Statera; E. Steffens; J. J. M. Steijger; F. Stinzing; S. Taroian; A. Terkulov; A. Trzcinski; M. Tytgat; A. Vandenbroucke; Y. Van Haarlem; C. Van Hulse; D. Veretennikov; V. Vikhrov; I. Vilardi; S. Wang; S. Yaschenko; S. Yen; W. Yu; B. Zihlmann; P. Zupranski

2011-05-02T23:59:59.000Z

372

Beta-decay branching ratios of 62Ga  

E-Print Network [OSTI]

Beta-decay branching ratios of 62Ga have been measured at the IGISOL facility of the Accelerator Laboratory of the University of Jyvaskyla. 62Ga is one of the heavier Tz = 0, 0+ -> 0+ beta-emitting nuclides used to determine the vector coupling constant of the weak interaction and the Vud quark-mixing matrix element. For part of the experimental studies presented here, the JYFLTRAP facility has been employed to prepare isotopically pure beams of 62Ga. The branching ratio obtained, BR= 99.893(24)%, for the super-allowed branch is in agreement with previous measurements and allows to determine the ft value and the universal Ft value for the super-allowed beta decay of 62Ga.

A. Bey; B. Blank; G. Canchel; C. Dossat; J. Giovinazzo; I. Matea; V. Elomaa; T. Eronen; U. Hager; M. Hakala; A. Jokinen; A. Kankainen; I. Moore; H. Penttila; S. Rinta-Antila; A. Saastamoinen; T. Sonoda; J. Aysto; N. Adimi; G. De France; J. C. Thomas; G. Voltolini; T. Chaventré

2008-04-17T23:59:59.000Z

373

Radar antenna pointing for optimized signal to noise ratio.  

SciTech Connect (OSTI)

The Signal-to-Noise Ratio (SNR) of a radar echo signal will vary across a range swath, due to spherical wavefront spreading, atmospheric attenuation, and antenna beam illumination. The antenna beam illumination will depend on antenna pointing. Calculations of geometry are complicated by the curved earth, and atmospheric refraction. This report investigates optimizing antenna pointing to maximize the minimum SNR across the range swath.

Doerry, Armin Walter; Marquette, Brandeis [General Atomics Aeronautical Systems, Inc., San Diego, CA

2013-01-01T23:59:59.000Z

374

Dilepton to photon ratio, a viscometer of QGP  

E-Print Network [OSTI]

In the Israel-Stewart's 2nd order hydrodynamics, a viscous effect on dilepton emission from a QGP medium is investigated. Dileptons are strongly affected by QGP viscosity. Large invariant mass dileptons, due to their lower velocity, are less affected by viscosity than the low invariant mass dileptons. We also show that the ratio of photon to dilepton is sensitive to the viscosity and can serve as a viscometer for QGP.

Chaudhuri, A K

2012-01-01T23:59:59.000Z

375

Combustion engine variable compression ratio apparatus and method  

DOE Patents [OSTI]

An apparatus and method for varying a compression ratio of an engine having a block and a head mounted thereto. The apparatus and method includes a cylinder having a block portion and a head portion, a piston linearly movable in the block portion of the cylinder, a cylinder plug linearly movable in the head portion of the cylinder, and a valve located in the cylinder plug and operable to provide controlled fluid communication with the block portion of the cylinder.

Lawrence; Keith E. (Peoria, IL); Strawbridge, Bryan E. (Dunlap, IL); Dutart, Charles H. (Washington, IL)

2006-06-06T23:59:59.000Z

376

The use of carbon stable isotope ratios in drugs characterization  

SciTech Connect (OSTI)

Isotopic Ratio Mass Spectrometry (IRMS) is an effective toll to be used for drug product authentication. The isotopic composition could be used to assist in the differentiation between batches of drugs and assist in the identification of counterfeit materials on the market. Only two factors affect the isotopic ratios in pharmaceutical components: the isotopic composition of the raw materials and the synthetic processes performed upon them. Counterfeiting of pharmaceutical drugs threatens consumer confidence in drug products companies' economical well-being. In this preliminary study, the analyzed samples consist in two types of commercially available analgesics, which were purchases from Romanian pharmacies. Differences in ?{sup 13}C between batches from ?29.7 to ?31.6% were observed, demonstrating that this method can be used to differentiate among individual drug batches and subsequently identify counterfeits on the market. On the other hand, carbon isotopic ratios differences among producers were recorded, the variations being between ?31.3 to ?34.9% for the same type of analgesic, but from different manufactures.

Magdas, D. A., E-mail: gabriela.cristea@itim-cj.ro; Cristea, G., E-mail: gabriela.cristea@itim-cj.ro; Bot, A., E-mail: gabriela.cristea@itim-cj.ro; Mirel, V., E-mail: gabriela.cristea@itim-cj.ro [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath Str., 400293 Cluj-Napoca (Romania)

2013-11-13T23:59:59.000Z

377

The E2/M1 ratio in {Delta} photoproduction  

SciTech Connect (OSTI)

The properties of the transition from the nucleon to the {Delta}(1232) serve as a benchmark for models of nucleon structure. To first order, N {r_arrow} {Delta} photo-excitation is dominated by a simple M1 quark spin-flip transition. At higher order, small L = 2 components in the N and {Delta} wavefunctions allow this excitation to proceed via an electric quadrupole transition. Since Nucleon models differ greatly on the mechanisms used to generate these L = 2 components,, the ratio of E2/M1 transitions (EMR) provides a sensitive test for structure models. Here, new high-precision measurements of p({rvec {gamma}}, {pi}) and p({rvec {gamma}}, {gamma}) cross sections and beam asymmetries have been combined with other polarization ratios in a simultaneous analysis of both reactions. Compton scattering has provided two important new constraints on the photo-pion amplitude. The E2/M1 mixing ratio for the N {r_arrow} {Delta} transition extracted from this analysis is EMR = {minus}3.0% {+-} 0.3 (stat+sys) {+-} 0.2 (model).

Sandorfi, A.M. [Brookhaven National Lab., Upton, NY (United States). Physics Dept.; Blanpied, G. [Univ. of South Carolina, Columbia, SC (United States). Dept. of Physics; Blecher, M. [Virginia Polytechnic Inst. and State Univ., Blacksburg, VA (United States). Physics Dept.] [and others; LEGS Collaboration

1997-08-01T23:59:59.000Z

378

Calculation of lung-heart ratios for single-photon emission computed tomography  

SciTech Connect (OSTI)

The authors investigate the effectiveness of simple iterative reconstruction techniques in calculating lung-heart activity ratios (LHRs). The LHR has been shown to be an effective indicator of the severity of coronary artery disease in cardiac SPECT. A study was conducted with a mathematical cardiac torso phantom that modelled uptake of {sup 201}Tl in the heart and lung regions. The projection data included only the effects of nonuniform photon attenuation. The data were first reconstructed with zeroth-order Chang and a variant of the Bellini method, both of which utilize information from the nonuniform attenuation map. This nonuniform (NU) Bellini method compensates exactly for attenuation in the heart region, but is incorrect for other regions in the medium. These reconstructions were then used as the initial estimates in the iterative Chang, variable step-size (VSS) Chang, and Morozumi methods,m for one and five iterations. The average heart count (AHC) and average lung count (ALC) were calculated using region-of-interest (ROI) templates derived from the true activity map. The population mean LHR was tabulated as the ratio of the ALC to AHC. Using the same reconstruction procedure, the authors also calculated the sample mean LHR and standard deviation from 21 noisy 3D reconstructions.

Soares, E.J.; King, M.A.; Glick, S.J.; Villegas, B.J. [Univ. of Massachusetts Medical Center, Worcester, MA (United States). Dept. of Nuclear Medicine] [Univ. of Massachusetts Medical Center, Worcester, MA (United States). Dept. of Nuclear Medicine

1996-06-01T23:59:59.000Z

379

air-fuel ratio control: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

was performed to investigate the effects of air-fuel ratio, inlet boost pressure, hydrogen rich fuel reformate, and compression ratio on engine knock behavior. For each...

380

E-Print Network 3.0 - abundance ratio measurements Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

O) coronal and transition region measurements of NeO ratio significantly higher... temperature independent emission line ratios - direct measurement of relative abundances use...

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Separated Response Function Ratios in Exclusive, Forward pi^{+/-} Electroproduction  

E-Print Network [OSTI]

The study of exclusive $\\pi^{\\pm}$ electroproduction on the nucleon, including separation of the various structure functions, is of interest for a number of reasons. The ratio $R_L=\\sigma_L^{\\pi^-}/\\sigma_L^{\\pi^+}$ is sensitive to isoscalar contamination to the dominant isovector pion exchange amplitude, which is the basis for the determination of the charged pion form factor from electroproduction data. A change in the value of $R_T=\\sigma_T^{\\pi^-}/\\sigma_T^{\\pi^+}$ from unity at small $-t$, to 1/4 at large $-t$, would suggest a transition from coupling to a (virtual) pion to coupling to individual quarks. Furthermore, the mentioned ratios may show an earlier approach to pQCD than the individual cross sections. We have performed the first complete separation of the four unpolarized electromagnetic structure functions above the dominant resonances in forward, exclusive $\\pi^{\\pm}$ electroproduction on the deuteron at central $Q^2$ values of 0.6, 1.0, 1.6 GeV$^2$ at $W$=1.95 GeV, and $Q^2=2.45$ GeV$^2$ at $W$=2.22 GeV. Here, we present the $L$ and $T$ cross sections, with emphasis on $R_L$ and $R_T$, and compare them with theoretical calculations. Results for the separated ratio $R_L$ indicate dominance of the pion-pole diagram at low $-t$, while results for $R_T$ are consistent with a transition between pion knockout and quark knockout mechanisms.

G. M. Huber; H. P. Blok; C. Butuceanu; D. Gaskell; T. Horn; D. J. Mack; D. Abbott; K. Aniol; H. Anklin; C. Armstrong; J. Arrington; K. Assamagan; S. Avery; O. K. Baker; B. Barrett; E. J. Beise; C. Bochna; W. Boeglin; E. J. Brash; H. Breuer; C. C. Chang; N. Chant; M. E. Christy; J. Dunne; T. Eden; R. Ent; H. Fenker; E. F. Gibson; R. Gilman; K. Gustafsson; W. Hinton; R. J. Holt; H. Jackson; S. Jin; M. K. Jones; C. E. Keppel; P. H. Kim; W. Kim; P. M. King; A. Klein; D. Koltenuk; V. Kovaltchouk; M. Liang; J. Liu; G. J. Lolos; A. Lung; D. J. Margaziotis; P. Markowitz; A. Matsumura; D. McKee; D. Meekins; J. Mitchell; T. Miyoshi; H. Mkrtchyan; B. Mueller; G. Niculescu; I. Niculescu; Y. Okayasu; L. Pentchev; C. Perdrisat; D. Pitz; D. Potterveld; V. Punjabi; L. M. Qin; P. E. Reimer; J. Reinhold; J. Roche; P. G. Roos; A. Sarty; I. K. Shin; G. R. Smith; S. Stepanyan; L. G. Tang; V. Tadevosyan; V. Tvaskis; R. L. J. van der Meer; K. Vansyoc; D. Van Westrum; S. Vidakovic; J. Volmer; W. Vulcan; G. Warren; S. A. Wood; C. Xu; C. Yan; W. -X. Zhao; X. Zheng; B. Zihlmann

2014-04-15T23:59:59.000Z

382

Neutrino flavor ratios as diagnostic of solar WIMP annihilation  

E-Print Network [OSTI]

We consider the neutrino (and antineutrino) flavors arriving at Earth for neutrinos produced in the annihilation of weakly interacting massive particles (WIMPs) in the Sun's core. Solar-matter effects on the flavor propagation of the resulting $\\agt$ GeV neutrinos are studied analytically within a density-matrix formalism. Matter effects, including mass-state level-crossings, influence the flavor fluxes considerably. The exposition herein is somewhat pedagogical, in that it starts with adiabatic evolution of single flavors from the Sun's center, with $\\theta_{13}$ set to zero, and progresses to fully realistic processing of the flavor ratios expected in WIMP decay, from the Sun's core to the Earth. In the fully realistic calculation, non-adiabatic level-crossing is included, as are possible nonzero values for $\\theta_{13}$ and the CP-violating phase $\\delta$. Due to resonance enhancement in matter, nonzero values of $\\theta_{13}$ even smaller than a degree can noticeably affect flavor propagation. Both normal and inverted neutrino-mass hierarchies are considered. Our main conclusion is that measuring flavor ratios (in addition to energy spectra) of $\\agt$ GeV solar neutrinos can provide discrinination between WIMP models. In particular, we demonstrate the flavor differences at Earth for neutrinos from the two main classes of WIMP final states, namely $W^+ W^-$ and 95% $b \\bar{b}$ + 5% $\\tau^+\\tau^-$. Conversely, if WIMP properties were to be learned from production in future accelerators, then the flavor ratios of $\\agt$ GeV solar neutrinos might be useful for inferring $\\theta_{13}$ and the mass hierarchy.

Ralf Lehnert; Thomas J. Weiler

2007-08-08T23:59:59.000Z

383

Poisson's Ratio and the Densification of Glass under High Pressure  

SciTech Connect (OSTI)

Because of a relatively low atomic packing density, (C{sub g}) glasses experience significant densification under high hydrostatic pressure. Poisson's ratio ({nu}) is correlated to C{sub g} and typically varies from 0.15 for glasses with low C{sub g} such as amorphous silica to 0.38 for close-packed atomic networks such as in bulk metallic glasses. Pressure experiments were conducted up to 25 GPa at 293 K on silica, soda-lime-silica, chalcogenide, and bulk metallic glasses. We show from these high-pressure data that there is a direct correlation between {nu} and the maximum post-decompression density change.

Rouxel, T.; Ji, H. [Applied Mechanics Laboratory of the University of Rennes 1, LARMAUR, Universite de Rennes 1, Campus de Beaulieu, 35042 Rennes cedex (France); Hammouda, T. [Laboratoire Magmas et Volcans, CNRS-OPG , Universite Blaise Pascal, 5 rue Kessler, 63038 Clermont-Ferrand cedex (France); Moreac, A. [IPR, CNRS-Universite de Rennes 1, Campus de Beaulieu, 35042 Rennes cedex (France)

2008-06-06T23:59:59.000Z

384

Method for producing thin graphite flakes with large aspect ratios  

DOE Patents [OSTI]

A method for making graphite flakes of high aspect ratio by the steps of providing a strong concentrated acid and heating the graphite in the presence of the acid for a time and at a temperature effective to intercalate the acid in the graphite; heating the intercalated graphite at a rate and to a temperature effective to exfoliate the graphite in discrete layers; subjecting the graphite layers to ultrasonic energy, mechanical shear forces, or freezing in an amount effective to separate the layes into discrete flakes.

Bunnell, L. Roy (Kennewick, WA)

1993-01-01T23:59:59.000Z

385

Quick Estimate of IRR From Capital Estimate Ratios  

E-Print Network [OSTI]

assumptions, as A useful factor can be calculated from the Net Present Values calculated above. The ratio of the Net Present Values gives the so call "Investment Equivalent of a unit of Savings," thus: $2332/$821 = $2.84 Capital/$l of Revenue...(Saving) If 15% (the assumption for discount rate, see Table I) is the minimum acceptable average earnings rate ("Hurdle rate") for a company, then the Investment Equivalent calculated above can be interpreted to mean: "The maximum among or Capital...

Larson, R. J.

386

Probability Tables for Mendelian Ratios with Small Numbers.  

E-Print Network [OSTI]

-called ex- Total ...-...-..-..-....-.--. .9999 pected may lead to error in interpretation rather than serving as a valuable aid as it does with large numbers. Examples with other small numbers could be given, but this should iIIustrate the points... is set off so as to show the point beyond which the total probability in that direction is .0050 or less. Mendelian Ratios Combi- 1 130 121 112 10 3 9 4 8 5 7 6 6 7 5 8 4 9 3 10 2 11 .On95 0028 .O002 .. -- I ---- - 1 12 .0016 .0004...

Warwick, B. L. (Bruce L.)

1932-01-01T23:59:59.000Z

387

Table E7.1. Consumption Ratios of Fuel, 1998  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative FuelsTotal" (Percent) Type: Sulfur Content API Gravity Period: Monthly Annual Download Series History71.7 588.51 "1. Consumption Ratios of

388

The University of Winnipeg Energy Management Policy  

E-Print Network [OSTI]

or disposal, and includes transportation and energy. Local Energy Source ­ any energy source within 500 reduce overall energy demand, and where energy is required, to give preference to local, renewable energy of energy. 3. Encourage the development and use of modes of transportation by students, administration

Martin, Jeff

389

Power Contro Energy Management and Market Systems  

SciTech Connect (OSTI)

More efficient use of the nation's electrical energy infrastructure will result in minimizing the cost of energy to the end user. Using real time electrical market information coupled with defined rules, market opportunities can be identified that provide economic benefit for both users and marketers of electricity. This report describes the design of one such system and the features a fully functional system would provide. This report documents several investigated methods of controlling load diversity or shifting.

Tom Addison; Andrew Stanbury

2005-12-15T23:59:59.000Z

390

PHEV Engine Control and Energy Management Strategy  

Broader source: Energy.gov (indexed) [DOE]

(RealTime Software and Hardware prototype control strategies development tools) - Matlab and Simulink (modeling environment) - Autonomie (vehicle and powertrain models) *...

391

Energy Management - Using Steam Pressure Efficiently  

E-Print Network [OSTI]

Saturated steam contains heat in two different forms. Sensible heat and latent heat. Due to the nature of this vapor, the relative proportion of latent heat is higher at lower pressures compared to higher pressures. When steam is used for heating...

Jiandani, N.

1983-01-01T23:59:59.000Z

392

Energy Management: Back to the Basics  

E-Print Network [OSTI]

In 2005, Texas Petrochemicals LP achieved a reduction in energy usage of 6.2 percent when compared to 2004. This is based on the but per pound of plant-wide production. Also, halfway through 2006, the company has achieved a reduction in energy usage...

Diamond, S.

2007-01-01T23:59:59.000Z

393

Energy Management Strategies for Existing Buildings  

E-Print Network [OSTI]

to improve, and how the future work force will need to prepare itself to respond. ESL-IC-09-11-11 Proceedings of the Ninth International Conference for Enhanced Building Operations, Austin, Texas, November 17 - 19, 2009 ...

Gilmer, L.

394

Federal Energy Management Program Organization Chart  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Legislative Affairs, Technology Deployment Nicolas Baker FEMP Website Joe Konrade O&M, Energy Security Cyrus Nasseri Interagency Coordination, Data Management Chris Tremper...

395

Local Area Networks - Applications to Energy Management  

E-Print Network [OSTI]

LOCAL AREA NETWORKS - APPLICATIONS TO MERCY MANAGmNT Advanced BRUCE M. BAKKEN Software bfanager Micro Syatems Corporation Milwaukee, WI ABSTRACT One of the newest advances in computer technology is the Local Area Network. Its many...

Bakken, B. M.

1984-01-01T23:59:59.000Z

396

Federal Government Energy Management Conservation Programs Reports...  

Broader source: Energy.gov (indexed) [DOE]

Policy Act (NECPA, Pub. L. No. 95-619), as amended, and provide information on energy consumption in Federal buildings, operations, and vehicles. Compiled by the Federal...

397

Diss. ETH No. 21036 Optimal Energy Management  

E-Print Network [OSTI]

Federal Office of Energy and Siemens Schweiz AG for the co-funding of my project. I am further indebted for their support and helpful discussions, namely Ivan L¨otscher, Markus Gwerder and Bruno Illi of Siemens Building and operating constraints are transformed into mixed-integer linear in- equalities to integrate them

Lygeros, John

398

Energy Management and the Conservation Investment Decision  

E-Print Network [OSTI]

This paper will describe briefly the model and method used to determine the value of the differential cash flow from an Energy Conservation Investment (E.C.I.). The key ingredients are the net effect on cash flow over the useful life...

DeLozier, T. C.

1983-01-01T23:59:59.000Z

399

Introducing Energy Management Systems into Smaller Facilities  

E-Print Network [OSTI]

Many small and medium sized commercial buildings are energy hogs. Typically they were designed and built to meet low first cost criteria. Control system capability is usually minimal, insulation is thin, glass areas are large, and HVAC equipment...

Lawrence, J. A.

1983-01-01T23:59:59.000Z

400

Integrating Energy Management and Lean Manufacturing  

E-Print Network [OSTI]

. BACKGROUND Manitoba Hydro is an energy utility headquartered in Winnipeg, Manitoba, Canada that serves over 500,000 electric customers throughout Manitoba and over 200,000 natural gas customers in various communities throughout southern Manitoba.... Nearly all the electricity generated is from water power from 14 hydroelectric generating stations. Additionally, Manitoba Hydro exports electricity to over 30 electric utilities through participation in four wholesale markets in North America. All...

Stocki, M.

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

ExxonMobil Global Energy Management System  

E-Print Network [OSTI]

of our refineries and chemical plants. The system builds on international best practices and benchmarking to identify energy efficiencies. Launched in 2000, it utilizes a common methodology to identify performance gaps, implement closure plans, sustain...

Roberto, F.

402

Effective Energy Management Through Better Operator Training  

E-Print Network [OSTI]

.Checl sh~m haps. 3. Check ins~'I'ltm.n~s. esp, Ttflu'A.,distlllQ.~ o:nd ftt~ flows. '" ~up ,"he cOrldensn c1e~n . 5, Check. itlSulo.Hon, 6 .Check. pum~s : ~o.cki118, belt sliPP~ imptllm, beati"&s. Ktep' spnri' dOWl1 un Ius l't~uired. 7, Heo.t in...) 8. In$t1ul1'leT\\td~ioYl 'J Pump Operahort J. e~c. Fi9.4: ~urndce Operations.! Common instruction media such as audio-visual cassettes, slides and technical manuals can be !used and i need no elaboration. Participants should also re...

Shah, G. C.

1979-01-01T23:59:59.000Z

403

Energy Management in the 1980's  

E-Print Network [OSTI]

requires significant capital investment. Several examples of such changes applicable to the 1980's are discussed along with the costs and benefits of the modifications. Exploitation of future opportunities will require major process changes, use of less...

Govindan, T. S.

1983-01-01T23:59:59.000Z

404

Corporate Energy Management- Perspectives and Motivations  

E-Print Network [OSTI]

There is no product, there is no service that can be provided without the need to expand or consume energy. Since the founding of these United States, our industrial capacity and national wealth had grown to be the greatest in the world...

Bessette, R. D.

405

Home Energy Management Systems and Reduced Consumption  

Broader source: Energy.gov [DOE]

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question "What emerging innovations are the key to future homes?"

406

Combined Thermal and Power Energy Management Optimization  

E-Print Network [OSTI]

, 'various types of prime movers (e.g. boilers, waste heat recovery, steam and gas turbines, etc.), and varying requirements for process heat and electrical power, particularly if bulk power is being dispatched to a utility grid. The ability... plants are generally characterized by multiple sources of energy, 'various types of prime movers (e.g. boilers, waste heat recovery. steam and gas turbines. etc.), and varying requirements for process heat and electrical power, particularly if bulk power...

Ahner, D. J.; Priestley, R. R.

407

Predictive Technology Development and Crash Energy Management  

Broader source: Energy.gov (indexed) [DOE]

* Rensselaer Polytechnic Institute * Nottingham University (UK) * Excel Pattern Works, Inc. Collaborators * Project start: 2007 * Project end: 2011 * Percent complete:...

408

Six Sigma in Enterprise Energy Management  

E-Print Network [OSTI]

, such as the use of energy. Recently General Electric (GE), one of the pioneers in the use of Six Sigma, selected Silicon Energy?s (now Itron) EEM Suite as the core technology for their Energ.ge program. The EEM Suite software solution included energy analysis..., cost analysis, event alarming and forecasting capabilities in addition to the collection platform for electric and gas meter data and rates information about energy consumption. This paper describes the Six Sigma approach used by GE for its Ener.ge...

Fuller, K.

2004-01-01T23:59:59.000Z

409

Energy Management Experience in Public Schools  

E-Print Network [OSTI]

Public schools have a continuing dilemma of escalating energy costs, deferred maintenance, and enrollment shift. Schools have experienced difficulty in dealing with budgeting and subsequent control of maintenance and operating costs. It is essential...

McClure, J. D.

1984-01-01T23:59:59.000Z

410

3M's Corporate Approach to Energy Management  

E-Print Network [OSTI]

recognized as a corporate environmental management leader and continues to demonstrate such leadership via the company's participation in EPA's Climate Wise and its own internal programs such as Pollution Prevention Pays (3P). Pamela R. Bingham...

Schultz, S. C.; Bingham, P. R.

411

Energy Management at Dow Chemical Co.  

E-Print Network [OSTI]

As one of the largest industrial consumers of energy in the world, The Dow Chemical Company and its 46,000 employees have put energy efficiency at the very core of its business – both as a cost savings initiative and as a primary corporate social...

Almaguer, J.

2008-01-01T23:59:59.000Z

412

Group Dynamics Approach to Industrial Energy Management  

E-Print Network [OSTI]

funding for major projects. I also tell how to get the most from utility rebate programs. I also describe strategies that did not work....

Thomas, D. G.

413

Outsourced Energy Management- A Trustee Approach  

E-Print Network [OSTI]

of providers is shrinking. Volatility in the creditworthiness of energy suppliers has compounded volatility in price. For executives responsible for facilities in many locations these issues are multiplied. With the imperative to control cost and optimize asset...

Ciarlone, D. F.; O'Connor, T. W.

414

Employee Motivation in Energy Management Programs  

E-Print Network [OSTI]

Effective management of energy requires the same degree of manager/employee motivation as other management responsibilities. Basically the same factors cause managers and employees to be motivated and effective. In this discussion, we will review...

Hogeland, A. W.

1982-01-01T23:59:59.000Z

415

Government Energy Management | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProvedDecember 2005DepartmentDecemberGlossary of Terms Glossary of TermsGosling

416

CONTINUED HIGH PERFORMANCE ENERGY MANAGEMENT COMPANY Fitesa  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation Proposed New Substation Sites Proposed Route BTRICGEGR-N Goods PO 1 of

417

PHEV Engine Control and Energy Management Strategy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l L d F SSales LLCDieselEnergyHistory andPEMFC R&DPaul H. Chambon

418

Guardian Energy Management Solutions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to: navigation,Ohio:Greer County is a county inAl., It is classified asFunanGuardian

419

Applied Energy Management | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300AlgoilEnergy Information the Army Permit:

420

Strategies for Enterprise-Wide Energy Management  

E-Print Network [OSTI]

for space heating purposes. In Gothenburg, Sweden, for example, the Volvo car factory and much of the city are supplied by waste heat from the local oil refineries. As companies invest in cogeneration to supply their internal power needs, it can...

Victor, A.

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

China's Energy Management System Program for Industry  

E-Print Network [OSTI]

Conference New Orleans, LA. May 20-23, 2014 | iipnetwork.org Waste Heat Recovery in Cement – Market Status 4 5 7 15 24 9 12 24 26 739 0 100 200 300 400 500 600 700 800 Rest of World Americas Europe Mid East Other Asia Pakistan Thailand Japan India China...MS Implementation guidance for Thermal Power – EnMS Implementation guidance for Coke – EnMS Implementation guidance Plate Coal Industry – M&V guidance on energy performance • 2015 – EnMS Implementation guidance for Paper – EnMS Implementation guidance...

Hedman, B.; Yu, Y.; Friedman, Z.; Taylor, R.

2014-01-01T23:59:59.000Z

422

Implementing a Corporate Energy Management System  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Results Worldwide Prevented the generation of 2.9 billion pounds of pollutants since 1975 with more than 7,400 3P projects. Cut volatile organic air emissions...

423

Rule-Based Energy Management System  

E-Print Network [OSTI]

in the summer the powerhouse can typically expect to shift from a maximum "buy" period to a maximum "make" period around 11: 00 a.m. Large economic penalties can occur in a short period of time if the powerhouse does not respond quickly to the swing... to DCS or PLC control when the EMS computer fails or communications is lost to either the PLC, DCS or GE Mark V controllers. This method of backup provides robust process control. However, when a failure occurs, optimization capability is lost...

Thomasson, F. Y.; Childress, R. L.

424

Energy Management and Financing | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana.Program -Department oftoThese Web sitesEERE Technologies

425

Southern Energy Management | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revisionEnvReviewNonInvasiveExplorationUT-g GrantAtlas (PACA Region -SonelgazSunbelt Wind Farm I Jump

426

Federal Energy Management Program | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels DataCombined Heat & PowerEnergy BlogExchangeSummaryFederal DigitalofFederal

427

Strategic Energy Management and Continuous Improvement Resouces |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of Energy Strain Rate Characterization of Advanced High

428

Mason Energy + Management | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to:46 - 429Lacey,(MonasterLowellis a townLoading map...(Redirected25. It isB. Places53.

429

Energy Management Programs at 3M Canada  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE:2009 DOEDeploymentHenry C. FoleyEnergy

430

Energy Management for Motor-Driven Systems  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE:2009 DOEDeploymentHenry C. FoleyEnergyW3-3EnergyENERGY

431

Federal Energy Management Program Organization Chart  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review:Department ofDistribution Infrastructure | DepartmentPortal User Guide |

432

Energy Management Inc EMI | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision has beenFfe2fb55-352f-473b-a2dd-50ae8b27f0a6 No revisionWind,SoilsfilesystemEvents UKSPARQLInc EMI Jump

433

ISO 50001 Conformant Energy Management Systems  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensionalthe U.S. Department ofIOWA RECOVERY50001 Brochure ISO 50001ISO

434

Implementing a Corporate Energy Management System  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensionalthe U.S. Department-2023Department of

435

Energy Management Centre | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address:011-DNA Jump37. It is classifiedProject)EnerVaultTechnologiesDelhiFuelMain Page

436

Energy Management Services LLC | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address:011-DNA Jump37. It is classifiedProject)EnerVaultTechnologiesDelhiFuelMain PageEnergy

437

Department of Energy Management Principles, May 2011  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power SystemsResources DOE Zero EnergyDataResearch CenterWind ProjectNevadaAmericaAcross

438

PHEV Engine Control and Energy Management Strategy  

Broader source: Energy.gov (indexed) [DOE]

any proprietary, confidential, or otherwise restricted information VSS013 2011 U.S. DOE Hydrogen Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation...

439

School Energy Management Through Continuous Commissioning®  

E-Print Network [OSTI]

at PHISD (Purely Hypothetical ISD): ? First six months to a year is GREAT! ? After Year 1?.. Warranty runs out?. ? Sensors go out of calibration, equipment gets overridden, maintenance may get overlooked resulting in perform equipment performance... know. Assuming originally Cx?d building at PHISD enjoyed a 50 mBtu/sqft EUI and reasonable energy rates, the future looks something like this? Energy performance degrades 1% - 5% per year (average ~2.5%) ? Data based on bldgs. From a famous...

Watt, J.

2012-01-01T23:59:59.000Z

440

Freescale Semiconductor Successfully Implements an Energy Management...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

28 million kilowatt hours (kWh) of electricity and 26,000 million British thermal units (Btu) of natural gas between 2006 and 2009, saving more than 2 million each year. Freescale...

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

New Curved Spacetime Dirac Equations - On the Anomalous Gyromagnetic Ratio  

E-Print Network [OSTI]

I propose three new curved spacetime versions of the Dirac Equation. These equations have been developed mainly to try and account in a natural way for the observed anomalous gyromagnetic ratio of Fermions. The derived equations suggest that particles including the Electron which is thought to be a point particle do have a finite spatial size which is the reason for the observed anomalous gyromagnetic ratio. A serendipitous result of the theory, is that, two of the equation exhibits an asymmetry in their positive and negative energy solutions the first suggestion of which is clear that a solution to the problem as to why the Electron and Muon - despite their acute similarities - exhibit an asymmetry in their mass is possible. The Mourn is often thought as an Electron in a higher energy state. Another of the consequences of three equations emanating from the asymmetric serendipity of the energy solutions of two of these equations, is that, an explanation as to why Leptons exhibit a three stage mass hierarchy is possible.

G. G. Nyambuya

2008-09-06T23:59:59.000Z

442

Tissue phantom ratios for a Clinac 4/100  

SciTech Connect (OSTI)

Tissue phantom ratios (TPR), based on a normalization depth of 5 cm, have been measured in water for field sizes from 5 x 5 cm/sup 2/ to approximately 40 x 40 cm/sup 2/ and for depths from 1 to 40 cm for a Varian Clinac 4/100. These TPR's have been compared with those calculated from percent depth doses measured at the same time, and the two sets of data generally agree to better than 1%, with an average ratio of measured to calculated TPR of 0.999 +- 0.013. Beam profiles have been measured for open and wedged fields, with particular concern for the often observed ''horns,'' or the increase in dose at the corners of the field. The maximum dose at a depth of 1 cm, along the diagonal of the field for this machine, is approximately 5% higher than at the same depth on the central axis, whereas along the principal plane the maximum dose is only about 3% higher.

Biggs, P.J.; Doppke, K.P.; Leong, J.C.; Russell, M.D.

1982-09-01T23:59:59.000Z

443

Bound for entropy and viscosity ratio for strange quark matter  

E-Print Network [OSTI]

High energy density ($\\eps$) and temperature (T) links general relativity and hydrodynamics leading to a lower bound for the ratio of shear viscosity ($\\eta$) and entropy density ($s$). We get the interesting result that the bound is saturated in the simple model for quark matter that we use for strange stars at the surface for $T \\sim 80 MeV$. At this $T$ we have the possibility of cosmic separation of phases. At the surface of the star where the pressure is zero - the density $\\eps$ has a fixed value for all stars of various masses with correspondingly varying central energy density $\\eps_c$. Inside the star where this density is higher, the ratio of $\\eta/s$ is larger and are like the known results found for perturbative QCD. This serves as a check of our calculation. The deconfined quarks at the surface of the strange star at $T = 80 MeV$ seem to constitute the most perfect interacting fluid permitted by nature.

Manjari Bagchi; Jishnu Dey; Mira Dey; Taparati Gangopadhyay; Sibasish Laha; Subharthi Ray; Monika Sinha

2008-07-03T23:59:59.000Z

444

Influence of Transport Variables on Isospin Transport Ratios  

E-Print Network [OSTI]

The symmetry energy in the nuclear equation of state affects many aspects of nuclear astrophysics, nuclear structure, and nuclear reactions. Recent constraints from heavy ion collisions, including isospin diffusion observables, have started to put constraints on the symmetry energy below nuclear saturation density, but these constraints depend on the employed transport model and input physics other than the symmetry energy. To understand these dependencies, we study the influence of the symmetry energy, isoscaler mean field compressibility and momentum dependence, in-medium nucleon-nucleon cross sections, and light cluster production on isospin diffusion within the pBUU transport code. In addition to the symmetry energy, several uncertain issues strongly affect isospin diffusion, most notably the cross sections and cluster production. In addition, there is a difference in the calculated isospin transport ratios, depending upon whether they are computed using the isospin asymmetry of either the residue or of all forward moving fragments. Measurements that compare the isospin transport ratios of these two quantities would help place constraints on the input physics, such as the density dependence of the symmetry energy.

D. D. S. Coupland; W. G. Lynch; M. B. Tsang; P. Danielewicz; Yingxun Zhang

2011-07-19T23:59:59.000Z

445

Cosmic ray muon charge ratio in the MINOS far detector  

SciTech Connect (OSTI)

The MINOS Far Detector is a 5.4 kiloton (5.2 kt steel plus 0.2 kt scintillator plus aluminum skin) magnetized tracking calorimeter located 710 meters underground in the Soudan mine in Northern Minnesota. MINOS is the first large, deep underground detector with a magnetic field and thus capable of making measurements of the momentum and charge of cosmic ray muons. Despite encountering unexpected anomalies in distributions of the charge ratio (N{sub {mu}{sup +}}/N{sub {mu}{sup -}}) of cosmic muons, a method of canceling systematic errors is proposed and demonstrated. The result is R{sub eff} = 1.346 {+-} 0.002 (stat) {+-} 0.016 (syst) for the averaged charge ratio, and a result for a rising fit to slant depth of R(X) = 1.300 {+-} 0.008 (stat) {+-} 0.016 (syst) + (1.8 {+-} 0.3) x 10{sup -5} x X, valid over the range of slant depths from 2000 < X < 6000 MWE. This slant depth range corresponds to minimum surface muon energies between 750 GeV and 5 TeV.

Beall, Erik B; /Minnesota U.

2005-12-01T23:59:59.000Z

446

Spherical codes, maximal local packing density, and the golden ratio  

E-Print Network [OSTI]

The densest local packing (DLP) problem in d-dimensional Euclidean space Rd involves the placement of N nonoverlapping spheres of unit diameter near an additional fixed unit-diameter sphere such that the greatest distance from the center of the fixed sphere to the centers of any of the N surrounding spheres is minimized. Solutions to the DLP problem are relevant to the realizability of pair correlation functions for packings of nonoverlapping spheres and might prove useful in improving upon the best known upper bounds on the maximum packing fraction of sphere packings in dimensions greater than three. The optimal spherical code problem in Rd involves the placement of the centers of N nonoverlapping spheres of unit diameter onto the surface of a sphere of radius R such that R is minimized. It is proved that in any dimension, all solutions between unity and the golden ratio to the optimal spherical code problem for N spheres are also solutions to the corresponding DLP problem. It follows that for any packing of nonoverlapping spheres of unit diameter, a spherical region of radius less than or equal to the golden ratio centered on an arbitrary sphere center cannot enclose a number of sphere centers greater than one more than the number that can be placed on the region's surface.

A. B. Hopkins; F. H. Stillinger; S. Torquato

2010-03-18T23:59:59.000Z

447

ARM: 10-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

10-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

Newsom, Rob; Goldsmith, John

448

ARM: 2-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

2-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

Sivaraman, Chitra; Flynn, Connor

449

ARM: 10-second Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

10-second Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

Sivaraman, Chitra; Flynn, Connor

450

ARM: 1-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

1-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

Sivaraman, Chitra; Flynn, Connor

451

Investigations of the properties of double ratio estimators  

E-Print Network [OSTI]

case, let YO , XO , end Xl only a a(Z) -~ 1 m c Z xl J~1 ylp a(Z) =~ E vO) g 1 70 r 2m (s. 5) 29 E yl a(Z)-~ a a E xp. j 1 yla r 3a xp Substituting (3. 5) in (1. 18) again, we get (N-a) n I- rla Xl + r2a Yp ? r3a Xp + ~gn-a 1 la xl..., showing that the ratio estimator is a consistent estimator of the population value and that the bias is negligible in large samples. Hartley and Ross ($) have given an exact expression for the bias: s s? r x Bias (r) - ? cov (r, x) / X--p X where...

Pizarro de Pereira, Norma

2012-06-07T23:59:59.000Z

452

Influence of Transport Variables on Isospin Transport Ratios  

E-Print Network [OSTI]

The symmetry energy in the nuclear equation of state affects many aspects of nuclear astrophysics, nuclear structure, and nuclear reactions. Recent constraints from heavy ion collisions, including isospin diffusion observables, have started to put constraints on the symmetry energy below nuclear saturation density, but these constraints depend on the employed transport model and input physics other than the symmetry energy. To understand these dependencies, we study the influence of the symmetry energy, isoscaler mean field compressibility and momentum dependence, in-medium nucleon-nucleon cross sections, and light cluster production on isospin diffusion within the pBUU transport code. In addition to the symmetry energy, several uncertain issues strongly affect isospin diffusion, most notably the cross sections and cluster production. In addition, there is a difference in the calculated isospin transport ratios, depending upon whether they are computed using the isospin asymmetry of either the residue or of a...

Coupland, D D S; Tsang, M B; Danielewicz, P; Zhang, Yingxun

2011-01-01T23:59:59.000Z

453

Modular low-aspect-ratio high-beta torsatron  

DOE Patents [OSTI]

A fusion-reactor device is described which the toroidal magnetic field and at least a portion of the poloidal magnetic field are provided by a single set of modular coils. The coils are arranged on the surface of a low-aspect-ratio toroid in planed having the cylindrical coordinate relationship phi = phi/sub i/ + kz, where k is a constant equal to each coil's pitch and phi/sub i/ is the toroidal angle at which the i'th coil intersects the z = o plane. The toroid defined by the modular coils preferably has a race track minor cross section. When vertical field coils and, preferably, a toroidal plasma current are provided for magnetic-field-surface closure within the toroid, a vacuum magnetic field of racetrack-shaped minor cross section with improved stability and beta valves is obtained.

Sheffield, G.V.

1982-04-01T23:59:59.000Z

454

Measurement of the K+ --> pi+ nu nu branching ratio  

SciTech Connect (OSTI)

Experiment E949 at Brookhaven National Laboratory studied the rare decay K{sup +}-->pi{sup +} nu{ovr {nu}} and other processes with an exposure of 1.77 x 10{sup 12} k{sup +}'s. The data were analyzed using a blind analysis technique yielding one candidate event with an estimated background of 0.30 {+-} 0.03 events. Combining this result with the observation of two candidate events by the predecessor experiment E787 gave the branching ratio B(K{sup +}-->pi{sup +} nu{ovr {nu}}) = (1.47{sub -0.89}{sup +1.30}) x 10{sup -10}, consistent with the standard model prediction of (0.74 {+-} 0.20) x 10{sup -10}. This is a more detailed report of results previously published [V.V. Anisimovsky et al., Phys. Rev. Lett. 93, 031801 (2004)].

Adler, S.; /Brookhaven; Anisimovsky, V.V.; /Moscow, INR; Aoki, M.; /TRIUMF; Ardebili, M.; /Princeton U.; Artamonov, A.V.; /Serpukhov, IHEP; Atiya, M.; /Brookhaven; Bassalleck, B.; /New Mexico U.; Bazarko, A.O.; /Princeton U.; Bhuyan, B.; /Brookhaven; Blackmore, E.W.; /TRIUMF; Bryman, D.A.; /British Columbia U. /Tsinghua U., Beijing /TRIUMF

2008-03-01T23:59:59.000Z

455

Slip ratio in dispersed viscous oil-water pipe flow  

SciTech Connect (OSTI)

In this article, dispersed flow of viscous oil and water is investigated. The experimental work was performed in a 26.2-mm-i.d. 12-m-long horizontal glass pipe using water and oil (viscosity of 100 mPa s and density of 860 kg/m{sup 3}) as test fluids. High-speed video recording and a new wire-mesh sensor based on capacitance (permittivity) measurements were used to characterize the flow. Furthermore, holdup data were obtained using quick-closing-valves technique (QCV). An interesting finding was the oil-water slip ratio greater than one for dispersed flow at high Reynolds number. Chordal phase fraction distribution diagrams and images of the holdup distribution over the pipe cross-section obtained via wire-mesh sensor indicated a significant amount of water near to the pipe wall for the three different dispersed flow patterns identified in this study: oil-in-water homogeneous dispersion (o/w H), oil-in-water non-homogeneous dispersion (o/w NH) and Dual continuous (Do/w and Dw/o). The phase slip might be explained by the existence of a water film surrounding the homogeneous mixture of oil-in-water in a hidrofilic-oilfobic pipe. (author)

Rodriguez, Iara H.; Yamaguti, Henrique K.B.; de Castro, Marcelo S.; Rodriguez, Oscar M.H. [Department of Mechanical Engineering, Engineering School of Sao Carlos, University of Sao Paulo (USP), Av. Trabalhador Sao Carlense, 400, 13566-970 Sao Carlos, SP (Brazil); Da Silva, Marco J. [Forschungszentrum Dresden-Rossendorf e. V., Institute of Safety Research, PO Box 510119, 01314 Dresden (Germany)

2011-01-15T23:59:59.000Z

456

Frequency ratio method for seismic modeling of Gamma Doradus stars  

E-Print Network [OSTI]

A method for obtaining asteroseismological information of a Gamma Doradus oscillating star showing at least three pulsation frequencies is presented. This method is based on a first-order asymptotic g-mode expression, in agreement with the internal structure of Gamma Doradus stars. The information obtained is twofold: 1) a possible identification of the radial order n and degree l of observed frequencies (assuming that these have the same l), and 2) an estimate of the integral of the buoyancy frequency (Brunt-Vaisala) weighted over the stellar radius along the radiative zone. The accuracy of the method as well as its theoretical consistency are also discussed for a typical Gamma Doradus stellar model. Finally, the frequency ratios method has been tested with observed frequencies of the Gamma Doradus star HD 12901. The number of representative models verifying the complete set of constraints (the location in the HR diagram, the Brunt-Vaisala frequency integral, the observed metallicity and frequencies and a re...

Moya, A; Amado, P J; Martin-Ruiz, S; Garrido, R

2004-01-01T23:59:59.000Z

457

Ethanol Conversion to Hydrocarbons on HZSM-5: Effect of Reaction Conditions and Si/Al Ratio on the Product Distributions  

SciTech Connect (OSTI)

The Conversion of ethanol to hydrocarbon over HZSM-5 zeolite with different Si/Al ratios was investigated under various reaction conditions. The catalyst with a higher Si/Al ratio (low acid density) deactivated faster and generated more unsaturated compounds at a similar time-on-stream. Temperature affects the catalytic activity with respect to liquid hydrocarbon generation and the hydrocarbon product composition. At lower temperatures (~300°C), the catalyst deactivated faster with respect to the liquid hydrocarbon formation. Higher temperatures (~400°C) reduced the formation of liquid range hydrocarbons and formed more gaseous fractions. Weight hourly space velocity was also found to affect product selectivity with higher weight hourly space velocity leading to a higher extent of ethylene formation. The experimental results were analyzed in terms of the product composition and the coke content with respect to catalyst time-on-stream and compared with the catalyst lifetime with respect to the variables tested on the conversion of ethanol to hydrocarbon.

Ramasamy, Karthikeyan K.; Wang, Yong

2014-11-17T23:59:59.000Z

458

In-patient to isocenter KERMA ratios in CT  

SciTech Connect (OSTI)

Purpose: To estimate in-patient KERMA for specific organs in computed tomography (CT) scanning using ratios to isocenter free-in-air KERMA obtained using a Rando phantom.Method: A CT scan of an anthropomorphic phantom results in an air KERMA K at a selected phantom location and air kerma K{sub CT} at the CT scanner isocenter when the scan is repeated in the absence of the phantom. The authors define the KERMA ratio (R{sub K}) as K/ K{sub CT}, which were experimentally determined in a Male Rando Phantom using lithium fluoride chips (TLD-100). R{sub K} values were obtained for a total of 400 individual point locations, as well as for 25 individual organs of interest in CT dosimetry. CT examinations of Rando were performed on a GE LightSpeed Ultra scanner operated at 80 kV, 120 kV, and 140 kV, as well as a Siemens Sensation 16 operated at 120 kV. Results: At 120 kV, median R{sub K} values for the GE and Siemens scanners were 0.60 and 0.64, respectively. The 10th percentile R{sub K} values ranged from 0.34 at 80 kV to 0.54 at 140 kV, and the 90th percentile R{sub K} values ranged from 0.64 at 80 kV to 0.78 at 140 kV. The average R{sub K} for the 25 Rando organs at 120 kV was 0.61 {+-} 0.08. Average R{sub K} values in the head, chest, and abdomen showed little variation. Relative to R{sub K} values in the head, chest, and abdomen obtained at 120 kV, R{sub K} values were about 12% lower in the pelvis and about 58% higher in the cervical spine region. Average R{sub K} values were about 6% higher on the Siemens Sensation 16 scanner than the GE LightSpeed Ultra. Reducing the x-ray tube voltage from 120 kV to 80 kV resulted in an average reduction in R{sub K} value of 34%, whereas increasing the x-ray tube voltage to 140 kV increased the average R{sub K} value by 9%. Conclusions: In-patient to isocenter relative KERMA values in Rando phantom can be used to estimate organ doses in similar sized adults undergoing CT examinations from easily measured air KERMA values at the isocenter (free in air). Conversion from in-patient air KERMA values to tissue dose would require the use of energy-appropriate conversion factors.

Huda, Walter; Ogden, Kent M.; Lavallee, Robert L.; Roskopf, Marsha L.; Scalzetti, Ernest M. [Department of Radiology and Radiological Science, Medical University of South Carolina (MUSC), 96 Jonathan Lucas Street (MSC 323), Charleston, South Carolina 29425-3230 (United States); Department of Radiology, SUNY Upstate Medical University, 750 E Adams Street, Syracuse, New York 13210 (United States)

2011-10-15T23:59:59.000Z

459

E-Print Network 3.0 - aspect ratios numerical Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: for high aspect ratio case. The importance of triangularity and of the q profile parameters has been shown... was limited to high aspect ratio. Now the results for...

460

Effects of operating conditions, compression ratio, and gasoline reformate on SI engine knock limits  

E-Print Network [OSTI]

A set of experiments was performed to investigate the effects of air-fuel ratio, inlet boost pressure, hydrogen rich fuel reformate, and compression ratio on engine knock behavior. For each condition the effect of spark ...

Gerty, Michael D

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

E-Print Network 3.0 - anhydrous molar ratios Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ratios of magnesium to tin... of compounds in MgOSnO2 system is given here. 2.1.1. Solid-state reaction (SSR) route Two molar ratios (1... product. The stoichiometric...

462

E-Print Network 3.0 - adenylate kinase activity Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

kinase controls the conversion... of AMP into ADP and modifies the ratios of AMP to ATP, adenylate kinase activity therefore plays... DNA and Gene for the Arabidopsis thaliana...

463

Modeling the interface area aspect ratio of carbide grains in WCCo composites  

E-Print Network [OSTI]

Modeling the interface area aspect ratio of carbide grains in WC­Co composites Xiaokun Yuan a Keywords: Cemented carbide Electron backscattered diffraction Interface area aspect ratio Five parameter analysis The average interface area aspect ratios of carbide grains in WC­Co composites are measured from

Rohrer, Gregory S.

464

An approach to determine a defensible spent fuel ratio.  

SciTech Connect (OSTI)

Sabotage of spent nuclear fuel casks remains a concern nearly forty years after attacks against shipment casks were first analyzed and has a renewed relevance in the post-9/11 environment. A limited number of full-scale tests and supporting efforts using surrogate materials, typically depleted uranium dioxide (DUO2), have been conducted in the interim to more definitively determine the source term from these postulated events. In all the previous studies, the postulated attack of greatest interest was by a conical shape charge (CSC) that focuses the explosive energy much more efficiently than bulk explosives. However, the validity of these large-scale results remain in question due to the lack of a defensible Spent Fuel Ratio (SFR), defined as the amount of respirable aerosol generated by an attack on a mass of spent fuel compared to that of an otherwise identical DUO2 surrogate. Previous attempts to define the SFR have resulted in estimates ranging from 0.42 to 12 and include suboptimal experimental techniques and data comparisons. Different researchers have suggested using SFR values of 3 to 5.6. Sound technical arguments exist that the SFR does not exceed a value of unity. A defensible determination of the SFR in this lower range would greatly reduce the calculated risk associated with the transport and dry storage of spent nuclear fuel. Currently, Oak Ridge National Laboratory (ORNL) is in possession of several samples of spent nuclear fuel (SNF) that were used in the original SFR studies in the 1980's and were intended for use in a modern effort at Sandia National Laboratories (SNL) in the 2000's. A portion of these samples are being used for a variety of research efforts. However, the entirety of SNF samples at ORNL is scheduled for disposition at the Waste Isolation Pilot Plant (WIPP) by approximately the end of 2015. If a defensible SFR is to be determined for use in storage and transportation security analyses, the need to begin this effort is urgent in order to secure the only known available SNF samples with a clearly defined path to disposal.

Durbin, Samuel G.; Lindgren, Eric Richard

2014-03-01T23:59:59.000Z

465

The impact of equivalence ratio oscillations on combustion dynamics in a backward-facing step combustor  

SciTech Connect (OSTI)

The combustion dynamics of propane-air flames are investigated in an atmospheric pressure, atmospheric inlet temperature, lean, premixed backward-facing step combustor. We modify the location of the fuel injector to examine the impact of equivalence ratio oscillations arriving at the flame on the combustion dynamics. Simultaneous pressure, velocity, heat-release rate and equivalence ratio measurements and high-speed video from the experiments are used to identify and characterize several distinct operating modes. When the fuel is injected far upstream from the step, the equivalence ratio arriving at the flame is steady and the combustion dynamics are controlled only by flame-vortex interactions. In this case, different dynamic regimes are observed depending on the operating parameters. When the fuel is injected close to the step, the equivalence ratio arriving at the flame exhibits oscillations. In the presence of equivalence ratio oscillations, the measured sound pressure level is significant across the entire range of lean mean equivalence ratios even if the equivalence ratio oscillations arriving at the flame are out-of-phase with the pressure oscillations. The combustion dynamics are governed primarily by the flame-vortex interactions, while the equivalence ratio oscillations have secondary effects. The equivalence ratio oscillations could generate variations in the combustion dynamics in each cycle under some operating conditions, destabilize the flame at the entire range of the lean equivalence ratios, and increase the value of the mean equivalence ratio at the lean blowout limit. (author)

Murat Altay, H.; Speth, Raymond L.; Hudgins, Duane E.; Ghoniem, Ahmed F. [Massachusetts Institute of Technology, Department of Mechanical Engineering, Cambridge, MA 02139 (United States)

2009-11-15T23:59:59.000Z

466

Data analysis, analytical support, and technology transfer support for the Federal Energy Management Program Office of Conservation and Renewable Energy Department of Energy. Final technical report, August 8, 1987--August 7, 1992  

SciTech Connect (OSTI)

Activities included the collecting, reporting, and analysis of Federal energy usage and cost data; development of program guidance and policy analysis of Federal energy usage and cost data; development of program guidance and policy analysis; inter-agency liaison; promotion of energy efficiency initiatives; and extensive technology transfer and outreach activities.

Tremper, C.

1992-12-31T23:59:59.000Z

467

activity body mass: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

index is directly related to the ratio between the physical quantities metabolic rate and heat loss. Apell, S P; Gawlitza, H 2011-01-01 7 Habitat-related activities and body mass...

468

Simulation study of areal sweep efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern  

E-Print Network [OSTI]

ratios on five-spot and staggered waterflood patterns behavior for areal (2D) displacement in a reservoir that is homogeneous and isotropic containing no initial gas saturation. Simulation was performed using Eclipse 100 simulator. Simulation results...

Guliyev, Ruslan

2008-10-10T23:59:59.000Z

469

Catalyst activator  

DOE Patents [OSTI]

A catalyst activator particularly adapted for use in the activation of metal complexes of metals of Group 3-10 for polymerization of ethylenically unsaturated polymerizable monomers, especially olefins, comprising two Group 13 metal or metalloid atoms and a ligand structure including at least one bridging group connecting ligands on the two Group 13 metal or metalloid atoms.

McAdon, Mark H. (Midland, MI); Nickias, Peter N. (Midland, MI); Marks, Tobin J. (Evanston, IL); Schwartz, David J. (Lake Jackson, TX)

2001-01-01T23:59:59.000Z

470

A comparison of the values of Poisson's ratio of rocks measured statically and dynamically  

E-Print Network [OSTI]

pressure (specimens 1251 and 1253 26 15, Poisson's ratio versus confining pressure (specimens 1270 and 1280 27 16. Poisson's ratio versus confining pressure (specimens 1296 and 1299 28 17. Poisson's ratio versus porosity at 5, 000 and 10, 000 psi... were taken at room temperature and under confining pressures ranging from 0 to 10, 000 psi. The measurements showed that the values, as measured by the two methods described, agreed very well at high confining pressures but varied at low pressures...

Marek, Benjamin Frank

1967-01-01T23:59:59.000Z

471

E-Print Network 3.0 - average aspect ratios Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

aspect ratio... results between them. Turbulent flow in enclosures with ... Source: Massachusetts at Amherst, University of - Center for Energy Efficiency and Renewable Energy,...

472

E-Print Network 3.0 - aspect ratio electrodes Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Fusion ; Engineering 56 Electrochemical study of dual conjugated polymer electrochromic devices Summary: , the redox charge ratio between the two constituting films, and...

473

E-Print Network 3.0 - aspect ratio Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

time scale of the resulting motion. In both series the initial aspect ratio a... two orders of magnitude. The initial basal lengths and range of aspect ... Source: Huppert,...

474

E-Print Network 3.0 - aspect ratio effects Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

time scale of the resulting motion. In both series the initial aspect ratio a... two orders of magnitude. The initial basal lengths and range of aspect ... Source: Huppert,...

475

E-Print Network 3.0 - aspect ratio wings Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

S., "Limit Cycle Oscillations in High-Aspect-Ratio Wings," Jour- nal of Fluids... of Aerodynamic and Structural Geometrical Nonlinearities on Aeroelastic Behavior of...

476

ablation-absorption ratio spectrometry: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

isotopes 2 A gas chromatographypyrolysisisotope ratio mass spectrometry system for high-precision dD measurements Environmental Sciences and Ecology Websites Summary: of...

477

Mass dependence of balance energy for different N/Z ratio  

E-Print Network [OSTI]

We present the study for the mass dependence of E$_{bal}$ for various N/Z ratios covering pure symmetric systems to highly neutron-rich ones.

Aman D. Sood

2011-09-28T23:59:59.000Z

478

aspect-ratio polymer microstructures: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

promising method for controlled coating of the inner surfaces of monolithic nanoporous aerogel (AG suited for coating substrates with ultrahigh aspect ratios (J103), including...

479

E-Print Network 3.0 - average likelihood ratio Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ABSTRACT Con dence... intervals are based on an inversion of the likelihood ratio statistic. To do this two extensions... of the likelihood, each of which yields meaningful...

480

E-Print Network 3.0 - avalanches branching ratios Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

20 J.Stat.Mech.(2010)P02015 ournal of Statistical Mechanics Summary: ) and subcritical dynamics: individual avalanches are either subcritical (average branching ratio...

Note: This page contains sample records for the topic "ratios energy-management activities" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Measurement of lithium isotope ratios by quadrupole-ICP-MS: application to seawater and natural carbonates  

E-Print Network [OSTI]

Measurement of lithium isotope ratios by quadrupole-ICP-MS: application to seawater and natural method for lithium isotope ratio (7 Li/6 Li) determinations with low total lithium consumption ( lithium from all matrix elements using small volume resin (2 ml/3.4 meq AG 50W-X8) and low volume elution

Weston, Ken

482

Rapidity dependence of the photon to pion production ratio in high energy collisions  

E-Print Network [OSTI]

We investigate rapidity dependence of the ratio of photon and pion production cross sections in high energy proton (deuteron) - nucleus collisions at RHIC and LHC. This ratio, and its rapidity dependence can be a sensitive probe of high density QCD (Color Glass Condensate) dynamics and shed further light on the role of saturation physics at RHIC and LHC.

Jamal Jalilian-Marian

2007-03-22T23:59:59.000Z

483

Predatorprey ratio and guild constancy in a tropical insect Oliver Kruger1  

E-Print Network [OSTI]

: the energy ratio and common determinants of diversity hypotheses were well supported and most likely were found and both energy ratio and common determinants of diversity hypotheses might explain are well established (Ricklefs, 1990; Holt, 1993; Polis & Wine- miller, 1996; Polis, Anderson & Holt, 1997

Krüger, Oliver

484

Signal-to-noise ratio of Geiger-mode avalanche photodiode single-photon  

E-Print Network [OSTI]

Signal-to-noise ratio of Geiger-mode avalanche photodiode single-photon counting detectors Kimberly Kolb #12;Signal-to-noise ratio of Geiger-mode avalanche photodiode single-photon counting detectors, Rochester, New York 14623 Abstract. Geiger-mode avalanche photodiodes (GM-APDs) use the avalanche mechanism

Figer, Donald F.

485

Puddle Dynamics and Air-to-Fuel Ratio Compensation for Gasoline-Ethanol Blends in  

E-Print Network [OSTI]

1 Puddle Dynamics and Air-to-Fuel Ratio Compensation for Gasoline-Ethanol Blends in Flex flexible fuel vehicles (FFVs) can operate on a blend of gasoline and ethanol in any concentration of up for gasoline-ethanol blends is, thus, necessary for the purpose of air-to-fuel ratio control. In this paper, we

Stefanopoulou, Anna

486

Quantification of Nanoscale Density Fluctuations in Biological Cells/Tissues: Inverse Participation Ratio (IPR) Analysis of  

E-Print Network [OSTI]

Ratio (IPR) Analysis of Transmission Electron Microscopy Images and Implications for Early-Stage Cancer analysis of the inverse participation ratio (IPR) of the eigenfunctions of these optical lattices at the nanoscales. First, the IPR analysis is validated in experiments with models of disordered systems fabricated

Pradhan, Prabhakar

487

Negative Association of Neuroticism with Brain Volume Ratio in Healthy Humans  

E-Print Network [OSTI]

Negative Association of Neuroticism with Brain Volume Ratio in Healthy Humans Brian Knutson, Reza Momenan, Robert R. Rawlings, Grace W. Fong, and Daniel Hommer Background: Brain volume decreases reactivity (i.e., neuroti- cism) would also predict reductions in brain volume. Methods: Brain volume ratios

Knutson, Brian

488

Frequency Ratio of ${}^{199}$Hg and ${}^{87}$Sr Optical Lattice Clocks beyond the SI Limit  

E-Print Network [OSTI]

We report on a frequency ratio measurement of a ${}^{199}$Hg-based optical lattice clock referencing a ${}^{87}$Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2 \\times 10^{-17}$ for the Hg clock. The frequency ratio is measured to be $\

Yamanaka, Kazuhiro; Ushijima, Ichiro; Takamoto, Masao; Katori, Hidetoshi

2015-01-01T23:59:59.000Z

489

DATABASE LIKELIHOOD RATIOS AND FAMILIAL DNA KLAAS SLOOTEN AND RONALD MEESTER  

E-Print Network [OSTI]

DATABASE LIKELIHOOD RATIOS AND FAMILIAL DNA SEARCHING KLAAS SLOOTEN AND RONALD MEESTER Abstract. Familial Searching is the process of searching in a DNA database for relatives of a given individual ratio, which is in this context called a Kinship Index. Suppose that the database contains, for a given

Meester, Ronald

490

Prediction of Ultra-High Aspect Ratio Nanowires from Self-Assembly  

E-Print Network [OSTI]

Prediction of Ultra-High Aspect Ratio Nanowires from Self-Assembly Zhigang Wu and Jeffrey C to investigate the possible self-assembly of nanoscale objects into ultrahigh aspect ratio chains and wires. Self-assembly17,18 from nanosize building blocks is regarded as one of the most promising methods

Wu, Zhigang

491

Steiner ratio typeset December 5, 1994 Smith & Smith Warren D. Smith  

E-Print Network [OSTI]

Steiner ratio typeset December 5, 1994 Smith & Smith Warren D. Smith 3 wds@research.nj.nec.com J. MacGregor Smith y jmsmith@umaecs.edu December 5, 1994 Abstract --- The ``Steiner minimal tree'' (SMT. This is a companion paper to D­Z. Du and W.D.Smith: Three disproofs of the Gilbert­Pollak Steiner ratio conjecture

Smith, J. MacGregor

492

Mapping the Energy Distribution of SERRS Hot Spots from Anti-Stokes to Stokes Intensity Ratios  

E-Print Network [OSTI]

Mapping the Energy Distribution of SERRS Hot Spots from Anti- Stokes to Stokes Intensity Ratios in the anti-Stokes to Stokes intensity ratios in single-molecule surface-enhanced resonance Raman scattering-enhanced Raman scattering. Moreover, a methodology to estimate the distribution of resonance energies

Brolo, Alexandre G.

493

Power and Effective Study Size Based on Approximations to the Expected Likelihood Ratio  

E-Print Network [OSTI]

Power and Effective Study Size Based on Approximations to the Expected Likelihood Ratio Test statistical power and precision of heritability estimates can be difficult particularly in complex pedigrees. Previous work focused on the power to detect heritability by using the expectation of the likelihood ratio

Washington at Seattle, University of

494

Modeling of Air-Fuel Ratio Dynamics of Gasoline Combustion Engine with ARX Network  

E-Print Network [OSTI]

DS-06-1351 Modeling of Air-Fuel Ratio Dynamics of Gasoline Combustion Engine with ARX Network Tomás dynamics of gasoline engines during transient operation. With a collection of input-output data measured;Modeling of Air-Fuel Ratio Dynamics of Gasoline Combustion Engine with ARX Network I. INTRODUCTION

Johansen, Tor Arne

495

Maximum entropy and Bayesian approaches to the ratio problem Edward Z. Shen*  

E-Print Network [OSTI]

Maximum entropy and Bayesian approaches to the ratio problem Edward Z. Shen* Jeffrey M. Perloff** January 2001 Abstract Maximum entropy and Bayesian approaches provide superior estimates of a ratio extra information in the supports for the underlying parameters for generalized maximum entropy (GME

Perloff, Jeffrey M.

496

UDC 622.276 A NEW APPROACH CALCULATE OIL-GAS RATIO  

E-Print Network [OSTI]

UDC 622.276 A NEW APPROACH CALCULATE OIL-GAS RATIO FOR GAS CONDENSATE AND VOLATILE OIL RESERVOIRS. In this work, we develop a new approach to calculate oil-gas ratio (Rv) by matching PVT experimental data laboratory analysis of eight gas condensate and five volatile oil fluid samples; selected under a wide range

Fernandez, Thomas

497

Master thesis project at the Netherlands Forensic Development and validation of Likelihood Ratio  

E-Print Network [OSTI]

Master thesis project at the Netherlands Forensic Institute: Development and validation of Likelihood Ratio methods In the forensic scientific community, it is widely accepted to present a likelihood in contributions from the Netherlands Forensic Institute to the Dutch legal system. A LR is defined as the ratio

Boucherie, Richard J.

498

Estimating the aggregate/intraaggregate mass ratio of a shrinking soil  

E-Print Network [OSTI]

A recently introduced parameter, the ratio of an aggregate solid mass to a solid mass of an intraaggregate matrix (K ratio) is connected with the mean thickness of a deformable, but non-shrinking surface layer of aggregates and is a fundamental property of aggregated soils that essentially influences their shrinkage. The objective of this work is to suggest and validate an approach to estimating the K ratio at any soil clay content through characteristics of soil texture and structure. We derive an equation that reflects the interrelation between the K ratio and soil texture and structure. The K ratio can be estimated as the solution of the equation and is determined by the mean size of soil solids and the maximum size of soil aggregates in the oven-dried state, independently of a measured shrinkage curve. To validate the approach we use available data for eight soils.

V. Y. Chertkov

2014-03-25T23:59:59.000Z

499

Additional Reserve Recovery Using New Polymer Treatment on High Water Oil Ratio Wells in Alameda Field, Kingman County, Kansas  

SciTech Connect (OSTI)

The Chemical Flooding process, like a polymer treatment, as a tertiary (enhanced) oil recovery process can be a very good solution based on the condition of this field and its low cost compared to the drilling of new wells. It is an improved water flooding method in which high molecular-weight (macro-size molecules) and water-soluble polymers are added to the injection water to improve the mobility ratio by enhancing the viscosity of the water and by reducing permeability in invaded zones during the process. In other words, it can improve the sweep efficiency by reducing the water mobility. This polymer treatment can be performed on the same active oil producer well rather than on an injector well in the existence of strong water drive in the formation. Some parameters must be considered before any polymer job is performed such as: formation temperature, permeability, oil gravity and viscosity, location and formation thickness of the well, amount of remaining recoverable oil, fluid levels, well productivity, water oil ratio (WOR) and existence of water drive. This improved oil recovery technique has been used widely and has significant potential to extend reservoir life by increasing the oil production and decreasing the water cut. This new technology has the greatest potential in reservoirs that are moderately heterogeneous, contain moderately viscous oils, and have adverse water-oil mobility ratios. For example, many wells in Kansas's Arbuckle formation had similar treatments and we have seen very effective results. In addition, there were previous polymer treatments conducted by Texaco in Alameda Field on a number of wells throughout the Viola-Simpson formation in the early 70's. Most of the treatments proved to be very successful.

James Spillane

2005-10-01T23:59:59.000Z

500

ARM: 10-minute TEMPORARY Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

10-minute TEMPORARY Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

Sivaraman, Chitra; Flynn, Connor