National Library of Energy BETA

Sample records for rates fo real

  1. 2013 guidance fo real Property Inventory Reporting | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    guidance fo real Property Inventory Reporting 2013 guidance fo real Property Inventory Reporting PDF icon SIGNED_FY13_Rpt_Instructions REV - 2013.08.15.pdf More Documents & Publications FY 2012 Federal Real Property Reporting Requirement FY09_Federal_Real_Property_Reporting_Requirements.pdf Guidance for Fiscal Year 2015 Facilities Information Management System Data Validations

  2. Towards More Transmission Asset Utilization through Real-time Path Rating

    SciTech Connect (OSTI)

    Diao, Ruisheng; Huang, Zhenyu; Jin, Chunlian; Vyakaranam, Bharat GNVSR; Jin, Shuangshuang; Makarov, Yuri V.

    2013-10-21

    Ratings of transmission paths, typically determined in an offline environment, are static and tend to be conservative, leading to underutilization of transmission assets, higher costs of system operation and renewable energy integration, and lower efficiency and savings. With the ever-increasing transmission congestion costs and new challenges from renewable integration, increasing transfer capacity of existing transmission lines is essential. Real-time path rating provides a promising approach to enabling additional power transfer capability and fully utilizing transfer capability. In this paper, the feasibility of real-time path rating is investigated. Several promising technologies to achieve real-time path rating are discussed. Various benefits that can be expected from real-time path rating, such as increased transfer capability and reduced total generation cost, are demonstrated through simulations conducted on the Western Electricity Coordinating Council system model.

  3. A Comparison of Real-Time Thermal Rating Systems in the U.S. and the U.K.

    SciTech Connect (OSTI)

    Gentle, Jake P.; Myers, Kurt S.; Bush, Jason W.; West, Isaac J.; Greenwood, David M.; Ingram, Grant L.; Davison, Peter J.; Troffaes, Matthias C.M.

    2014-08-01

    Real-time thermal rating is a smart-grid technology that allows the rating of electrical conductors to be increased based on local weather conditions. Overhead lines are conventionally given a conservative, constant seasonal rating based on seasonal and regional worst case scenarios rather than actual, say, local hourly weather predictions. This paper provides a report of two pioneering schemes-one in the U.S. and one in the U.K.-where real-time thermal ratings have been applied. Thereby, we demonstrate that observing the local weather conditions in real time leads to additional capacity and safer operation. Second, we critically compare both approaches and discuss their limitations. In doing so, we arrive at novel insights which will inform and improve future real-time thermal rating projects.

  4. Solar San Diego: The Impact of Binomial Rate Structures on Real PV Systems; Preprint

    SciTech Connect (OSTI)

    VanGeet, O.; Brown, E.; Blair, T.; McAllister, A.

    2008-05-01

    There is confusion in the marketplace regarding the impact of solar photovoltaics (PV) on the user's actual electricity bill under California Net Energy Metering, particularly with binomial tariffs (those that include both demand and energy charges) and time-of-use (TOU) rate structures. The City of San Diego has extensive real-time electrical metering on most of its buildings and PV systems, with interval data for overall consumption and PV electrical production available for multiple years. This paper uses 2007 PV-system data from two city facilities to illustrate the impacts of binomial rate designs. The analysis will determine the energy and demand savings that the PV systems are achieving relative to the absence of systems. A financial analysis of PV-system performance under various rate structures is presented. The data revealed that actual demand and energy use benefits of binomial tariffs increase in summer months, when solar resources allow for maximized electricity production. In a binomial tariff system, varying on- and semi-peak times can result in approximately $1,100 change in demand charges per month over not having a PV system in place, an approximate 30% cost savings. The PV systems are also shown to have a 30%-50% reduction in facility energy charges in 2007.

  5. In vivo real-time dosimetric verification in high dose rate prostate brachytherapy

    SciTech Connect (OSTI)

    Seymour, Erin L.; Downes, Simon J.; Fogarty, Gerald B.; Izard, Michael A.; Metcalfe, Peter

    2011-08-15

    Purpose: To evaluate the performance of a diode array in the routine verification of planned dose to points inside the rectum from prostate high dose rate (HDR) brachytherapy using a real-time planning system. Methods: A dosimetric study involving 28 patients was undertaken where measured doses received during treatment were compared to those calculated by the treatment planning system (TPS). After the ultrasound imaging required for treatment planning had been recorded, the ultrasound probe was replaced with a geometric replica that contained an 8 mm diameter cylindrical cavity in which a PTW diode array type 9112 was placed. The replica probe was then positioned inside the rectum with the individual diode positions determined using fluoroscopy. Dose was then recorded during the patients' treatment and compared to associated coordinates in the planning system. Results: Factors influencing diode response and experimental uncertainty were initially investigated to estimate the overall uncertainty involved in dose measurements, which was determined to be {+-}10%. Data was acquired for 28 patients' first fractions, 11 patients' second fractions, and 13 patients' third fractions with collection dependent upon circumstances. Deviations between the diode measurements and predicted values ranged from -42% to +35% with 71% of measurements experiencing less than a 10% deviation from the predicted values. If the {+-}10% measurement uncertainty was combined with a tolerated dose discrepancy of {+-}10% then over 95% of the diode results exhibited agreement with the calculated data to within {+-}20%. It must also be noted that when large dose discrepancies were apparent they did not necessarily occur for all five diodes in the one measurement. Conclusions: This technique provided a method that could be utilized to detect gross errors in dose delivery of a real-time prostate HDR plan. Limitations in the detection system used must be well understood if meaningful results are to be achieved.

  6. ITP Steel: Energy and Environmental Profile fo the U.S. Iron...

    Office of Environmental Management (EM)

    Steel: Energy and Environmental Profile fo the U.S. Iron and Steel Industry ITP Steel: Energy and Environmental Profile fo the U.S. Iron and Steel Industry PDF icon...

  7. I RADIOLOGICAL SCOPING SURVEY OF FO,RMER MONSANTO' FACILITIES

    Office of Legacy Management (LM)

    -I a.d *4dk *-f--l- --- I. ,e-- - .- --_ -- -. ;,. -* " . I . RADIOLOGICAL SCOPING SURVEY OF FO,RMER MONSANTO' FACILITIES (Unit XII and W a rehouse) DAYTON, OHIO Report Date: 4 September 1997 Survey Dak 27 Aitgust 1991 Prepared by: Mark L. Mays, Chief Radiation Safety Branch Sponsored by: M iamisburg Environmental Matigement Reject Office Ohio FTekl Ofice U.S.. Department of Energy Conducted by: %diation Safety Branch Of&e of Environmental Management ggtb Air Base W ing U.S. Departmtnt

  8. An evaluation of technologies for real-time measurement of rates of outdoor airflow into HVAC systems

    SciTech Connect (OSTI)

    Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

    2004-09-01

    During the last few years, new technologies have been introduced for real-time continuous measurement of the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for a controlled evaluation of these measurement technologies. The results of tests of four commercially available measurement technologies and one prototype based on a new design are also summarized. The test system and protocol were judged practical and very useful. The series of tests identified three commercially available measurement technologies that should provide reasonably accurate measurements of OA flow rates as long as air velocities are maintained high enough to produce accurately measurable pressure signals. In HVAC systems with economizer controls, to maintain the required air velocities the OA intake will need to be divided into two sections in parallel, each with a separate OA damper. The errors in OA flow rates measured with the fourth commercially available measurement technology were 20% to 30% with horizontal probes but much larger with vertical probes. The new prototype measurement technology was the only one that appears suitable for measuring OA flow rates over their full range from 20% OA to 100% OA without using two separate OA dampers. All of the measurement devices had pressure drops that are likely to be judged acceptable. The influence of wind on the accuracy of these measurement technologies still needs to be evaluated.

  9. FY 2012 Federal Real Property Reporting Requirement | Department of Energy

    Office of Environmental Management (EM)

    Federal Real Property Reporting Requirement FY 2012 Federal Real Property Reporting Requirement PDF icon FRPC Reporting Instructions 2012 final.pdf More Documents & Publications 2013 guidance fo real Property Inventory Reporting FY09_Federal_Real_Property_Reporting_Requirements.pdf Guidance for Fiscal Year 2015 Facilities Information Management System Data Validations

  10. WA_00_022_CARGILL_DOW_POLYMERS_LLC_Waiver_of_Domestic_and_Fo.pdf |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy 22_CARGILL_DOW_POLYMERS_LLC_Waiver_of_Domestic_and_Fo.pdf WA_00_022_CARGILL_DOW_POLYMERS_LLC_Waiver_of_Domestic_and_Fo.pdf PDF icon WA_00_022_CARGILL_DOW_POLYMERS_LLC_Waiver_of_Domestic_and_Fo.pdf More Documents & Publications WA_04_033_CARGILL_Waiver_of_Patent_Rights_to_CARGILL_DOWN_L.pdf WA_03_029_CARGILL_DOW_LLC_Waiver_of_Domestic_and_Foreign_Pat.pdf WA_02_052_CARGILL_DOW_Waiver_of_Domestic_and_Foreign_Patent_

  11. ITP Steel: Energy and Environmental Profile fo the U.S. Iron and Steel

    Office of Environmental Management (EM)

    Industry | Department of Energy Steel: Energy and Environmental Profile fo the U.S. Iron and Steel Industry ITP Steel: Energy and Environmental Profile fo the U.S. Iron and Steel Industry PDF icon steel_profile.pdf More Documents & Publications ITP Steel: Energy and Environmental Profile fo the U.S. Iron and Steel Industry Bandwidth Study U.S. Iron and Steel Manufacturing ITP Steel: Theoretical Minimum Energies to Produce Steel for Selected Conditions, March 2000 ITP Steel: Steel

  12. FY09_Federal_Real_Property_Reporting_Requirements.pdf | Department of

    Office of Environmental Management (EM)

    Energy FY09_Federal_Real_Property_Reporting_Requirements.pdf FY09_Federal_Real_Property_Reporting_Requirements.pdf PDF icon FY09_Federal_Real_Property_Reporting_Requirements.pdf More Documents & Publications 2013 guidance fo real Property Inventory Reporting FY 2012 Federal Real Property Reporting Requirement Guidance for Fiscal Year 2015 Facilities Information Management System Data Validations

  13. F.O. Licht's 17th Annual World Ethanol & Biofuels Conference

    Broader source: Energy.gov [DOE]

    The F.O. Licht's 17th Annual World Ethanol & Biofuels Conference will be held on November 3–6, 2014, in Budapest, Hungary. Valerie Reed, Deputy Director of the Bioenergy Technolgies Office will be serving on two panels: "Maintaining Next Generation Investments in the Years Ahead" on November 4 and "Putting Together a Constant Supply of Feedstocks for Advanced and Cellulosic Biofuels, Biochemicals and Aviation Fuels" on November 5.

  14. Grazing incidence angle based sensing approach integrated with fiber-optic Fourier transform infrared (FO-FTIR) spectroscopy for remote and label-free detection of medical device contaminations

    SciTech Connect (OSTI)

    Hassan, Moinuddin Ilev, Ilko

    2014-10-15

    Contamination of medical devices has become a critical and prevalent public health safety concern since medical devices are being increasingly used in clinical practices for diagnostics, therapeutics and medical implants. The development of effective sensing methods for real-time detection of pathogenic contamination is needed to prevent and reduce the spread of infections to patients and the healthcare community. In this study, a hollow-core fiber-optic Fourier transform infrared spectroscopy methodology employing a grazing incidence angle based sensing approach (FO-FTIR-GIA) was developed for detection of various biochemical contaminants on medical device surfaces. We demonstrated the sensitivity of FO-FTIR-GIA sensing approach for non-contact and label-free detection of contaminants such as lipopolysaccharide from various surface materials relevant to medical device. The proposed sensing system can detect at a minimum loading concentration of approximately 0.7 ?g/cm{sup 2}. The FO-FTIR-GIA has the potential for the detection of unwanted pathogen in real time.

  15. False Negative Rates of a Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates via Real-Time PCR

    SciTech Connect (OSTI)

    Hutchison, Janine R.; Piepel, Gregory F.; Amidan, Brett G.; Sydor, Michael A.; Deatherage Kaiser, Brooke L

    2015-05-01

    Surface sampling for Bacillus anthracis spores has traditionally relied on detection via bacterial cultivation methods. Although effective, this approach does not provide the level of organism specificity that can be gained through molecular techniques. False negative rates (FNR) and limits of detection (LOD) were determined for two B. anthracis surrogates with modified rapid viability-polymerase chain reaction (mRV-PCR) following macrofoam-swab sampling. This study was conducted in parallel with a previously reported study that analyzed spores using a plate-culture method. B. anthracis Sterne (BAS) or B. atrophaeus Nakamura (BG) spores were deposited onto four surface materials (glass, stainless steel, vinyl tile, and plastic) at nine target concentrations (2 to 500 spores/coupon; 0.078 to 19.375 colony-forming units [CFU] per cm²). Mean FNR values for mRV-PCR analysis ranged from 0 to 0.917 for BAS and 0 to 0.875 for BG and increased as spore concentration decreased (over the concentrations investigated) for each surface material. FNRs based on mRV-PCR data were not statistically different for BAS and BG, but were significantly lower for glass than for vinyl tile. FNRs also tended to be lower for the mRV-PCR method compared to the culture method. The mRV-PCR LOD₉₅ was lowest for glass (0.429 CFU/cm² with BAS and 0.341 CFU/cm² with BG) and highest for vinyl tile (0.919 CFU/cm² with BAS and 0.917 CFU/cm² with BG). These mRV-PCR LOD₉₅ values were lower than the culture values (BAS: 0.678 to 1.023 CFU/cm² and BG: 0.820 to 1.489 CFU/cm²). The FNR and LOD₉₅ values reported in this work provide guidance for environmental sampling of Bacillus spores at low concentrations.

  16. Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

    SciTech Connect (OSTI)

    Zhou Jun; Sebastian, Evelyn; Mangona, Victor; Yan Di

    2013-02-15

    Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.

  17. Trends in Real Estate and Energy Efficiency -- Update on Program...

    Broader source: Energy.gov (indexed) [DOE]

    Program Sustainability Peer Exchange Call Series: Trends in Real Estate and Energy ... Building Energy Rating and Disclosure Policies Trends in Real Estate and Energy Efficiency ...

  18. Development of an aerosol microphysical module: Aerosol Two-dimensional bin module for foRmation and Aging Simulation (ATRAS)

    SciTech Connect (OSTI)

    Matsui, H.; Koike, Makoto; Kondo, Yutaka; Fast, Jerome D.; Takigawa, M.

    2014-09-30

    Number concentrations, size distributions, and mixing states of aerosols are essential parameters for accurate estimation of aerosol direct and indirect effects. In this study, we developed an aerosol module, designated Aerosol Two-dimensional bin module for foRmation and Aging Simulation (ATRAS), that can represent these parameters explicitly by considering new particle formation (NPF), black carbon (BC) aging, and secondary organic aerosol (SOA) processes. A two-dimensional bin representation is used for particles with dry diameters from 40 nm to 10 m to resolve both aerosol size (12 bins) and BC mixing state (10 bins) for a total of 120 bins. The particles with diameters from 1 to 40 nm are resolved using an additional 8 size bins to calculate NPF. The ATRAS module was implemented in the WRF-chem model and applied to examine the sensitivity of simulated mass, number, size distributions, and optical and radiative parameters of aerosols to NPF, BC aging and SOA processes over East Asia during the spring of 2009. BC absorption enhancement by coating materials was about 50% over East Asia during the spring, and the contribution of SOA processes to the absorption enhancement was estimated to be 10 20% over northern East Asia and 20 35% over southern East Asia. A clear north-south contrast was also found between the impacts of NPF and SOA processes on cloud condensation nuclei (CCN) concentrations: NPF increased CCN concentrations at higher supersaturations (smaller particles) over northern East Asia, whereas SOA increased CCN concentrations at lower supersaturations (larger particles) over southern East Asia. Application of ATRAS to East Asia also showed that the impact of each process on each optical and radiative parameter depended strongly on the process and the parameter in question. The module can be used in the future as a benchmark model to evaluate the accuracy of simpler aerosol models and examine interactions between NPF, BC aging, and SOA processes under different meteorological conditions and emissions.

  19. Real Performance for Real Buildings (RPRB)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Performance for Real Buildings (RPRB) 2014 Building Technologies Office Peer Review New Project for FY14 Shanti Pless, shanti.pless@nrel.gov NREL 2 The Components OPERATIONS RISK OF REALIZATION BEST PRACTICES MANAGE DESIGN real performance for real performance Project Summary Timeline: Start date: October 1, 2013 Planned end date: September 30, 2014 Key Milestones Guides to help HPB buildings perform as expected; 9/30/14 1. Maintain performance in operations 2. Reduce performance risk in

  20. Rate Information

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    links Financial Information Financial Public Processes Asset Management Cost Verification Process Rate Cases Rate Information Current Power Rates Current Transmission Rates...

  1. Badging, Real ID

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Office » Badging, Real ID Badging, Real ID Effective Nov. 3, 2014, the Lab will implement requirements of the REAL ID Act. Contact Badge Office (505) 667-6901 Email Badge requirements US citizen employees must present a photo ID and proof of US citizenship. See Security Smart on Proof of United States Citizenship for the Badge Office (pdf). Foreign national guests and employees must have an approved visit and present a valid passport and documentation of US legal status and work authorizations.

  2. Real Property Asset Management

    Broader source: Energy.gov [DOE]

    The Real Property Asset Management (RPAM) portion of Deactivation & Decommissioning/Facility Engineering (D&D/FE) presents a driving programmatic challenge within the EM-D&D Clean-up...

  3. Rate Schedules

    Broader source: Energy.gov [DOE]

    One of the major responsibilities of Southeastern is to design, formulate, and justify rate schedules. Repayment studies prepared by the agency determine revenue requirements and appropriate rate...

  4. Real Property Asset Management

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2003-09-24

    The directive establishes an integrated corporate-level, performance based approach to the life-cycle management of our real property assets. It links real property asset planning, programming, budgeting and evaluation to the Department's multi-faceted missions. Successful implementation of this order will enable the Department to carry out our stewardship responsibilities, and will ensure that our facilities and infrastructure are properly sized and in a condition to meet our mission requirements today and in the future. Chg 1, dated 2-8-08. Chg 2, dated 4-25-11

  5. Real Property Asset Management

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2003-09-24

    The directive establishes an integrated corporate-level, performance based approach to the life-cycle management of our real property assets. It links real property asset planning, programming, budgeting and evaluation to the Department's multi-faceted missions. Successful implementation of this order will enable the Department to carry out our stewardship responsibilities, and will ensure that our facilities and infrastructure are properly sized and in a condition to meet our mission requirements today and in the future. Cancels: DOE O 430.1A. Chg 1, dated 2-8-08. Chg 2, dated 4-25-11

  6. Real Estate Approvals | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Estate Approvals Real Estate Approvals Real Estate Approvals Policy Flash 2011-61, Acquisition Guide Chapter 17.3, Acquisition, Use, and Disposal of Real Estate (attachment)...

  7. Real Estate Approvals | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Estate Approvals Real Estate Approvals Real Estate Approvals Policy Flash 2011-61, Acquisition Guide Chapter 17.3, Acquisition, Use, and Disposal of Real Estate (attachment)

  8. Finance & Rates

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    all of its costs in the rates it charges customers for wholesale electricity and transmission services. The agency is committed to careful cost management consistent with its...

  9. CASL - Keeping It Real

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Keeping It Real To ensure its modeling and simulation research activities are appropriately focused on specific industry issues, CASL engages an Industry Council chaired by the Electric Power Research Institute. CASL is committed to engaging the nuclear power industry to ensure its research is "used and useful" and positively contributes to the ability to generate safe, reliable, economical, and carbon-free electricity from nuclear power. In his visit to the CASL facilities at Oak

  10. Real-World Models

    Energy Savers [EERE]

    Real-World Models DOE and its national labs currently engage in a number of consortia with industry aimed at different targets for different technologies. To illustrate how different consortia organize to achieve these targets, Table 1 outlines the essential components and characteristics of several successful DOE consortia. Table 1. Summary of Consortia Advanced Engine Combustion Consortium (AEC) Lead Organization Membership Combustion Research Facility (CRF) at Sandia National Laboratories

  11. Real ID Act in brief

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Visitors » Badging, Badge Office » Real ID Act in brief Real ID Act in brief Effective Nov. 3, 2014, the Lab will implement requirements of the REAL ID Act. Contact Badge Office (505) 667-6901 Email REAL ID Act in brief REAL ID is a coordinated effort by the states and the Federal Government to improve the reliability and accuracy of state-issued identification documents, which should inhibit terrorists' ability to evade detection by using fraudulent identification. REAL ID implements a 9/11

  12. Real time Faraday spectrometer

    DOE Patents [OSTI]

    Smith, Jr., Tommy E. (Fremont, CA); Struve, Kenneth W. (Albuquerque, NM); Colella, Nicholas J. (Livermore, CA)

    1991-01-01

    This invention uses a dipole magnet to bend the path of a charged particle beam. As the deflected particles exit the magnet, they are spatially dispersed in the bend-plane of the magnet according to their respective momenta and pass to a plurality of chambers having Faraday probes positioned therein. Both the current and energy distribution of the particles is then determined by the non-intersecting Faraday probes located along the chambers. The Faraday probes are magnetically isolated from each other by thin metal walls of the chambers, effectively providing real time current-versus-energy particle measurements.

  13. Sustainability in Real Estate Operations

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Convention Center * Phoenix, Arizona Sustainability in Real Estate Operations Sustainability Sustainability Planning Eleni Reed GSA Public Buildings Service August 11, 2015 Sustainability in Real Estate Operations GSA incorporates sustainability practices in real estate operations Sustainability performance is an integral aspect of GSA's real estate operations 3 GSA PORTFOLIO 8,721 total assets * 376.9 million sq. ft. 1,574 owned assets * 183.4 million owned sq. ft. 7,147 leased assets * 193.4

  14. Real time automated inspection

    DOE Patents [OSTI]

    Fant, K.M.; Fundakowski, R.A.; Levitt, T.S.; Overland, J.E.; Suresh, B.R.; Ulrich, F.W.

    1985-05-21

    A method and apparatus are described relating to the real time automatic detection and classification of characteristic type surface imperfections occurring on the surfaces of material of interest such as moving hot metal slabs produced by a continuous steel caster. A data camera transversely scans continuous lines of such a surface to sense light intensities of scanned pixels and generates corresponding voltage values. The voltage values are converted to corresponding digital values to form a digital image of the surface which is subsequently processed to form an edge-enhanced image having scan lines characterized by intervals corresponding to the edges of the image. The edge-enhanced image is thresholded to segment out the edges and objects formed by the edges by interval matching and bin tracking. Features of the objects are derived and such features are utilized to classify the objects into characteristic type surface imperfections. 43 figs.

  15. Real time automated inspection

    DOE Patents [OSTI]

    Fant, Karl M. (Minneapolis, MN); Fundakowski, Richard A. (Saint Paul, MN); Levitt, Tod S. (Minneapolis, MN); Overland, John E. (Plymouth, MN); Suresh, Bindinganavle R. (New Brighton, MN); Ulrich, Franz W. (Minneapolis, MN)

    1985-01-01

    A method and apparatus relating to the real time automatic detection and classification of characteristic type surface imperfections occurring on the surfaces of material of interest such as moving hot metal slabs produced by a continuous steel caster. A data camera transversely scans continuous lines of such a surface to sense light intensities of scanned pixels and generates corresponding voltage values. The voltage values are converted to corresponding digital values to form a digital image of the surface which is subsequently processed to form an edge-enhanced image having scan lines characterized by intervals corresponding to the edges of the image. The edge-enhanced image is thresholded to segment out the edges and objects formed by the edges are segmented out by interval matching and bin tracking. Features of the objects are derived and such features are utilized to classify the objects into characteristic type surface imperfections.

  16. Real Property | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Property Real Property DOE has the unique authority under the Atomic Energy Act to dispose or transfer property under certain conditions or to access the services of the General Services Administration to dispose excess real property. During the last 10 years, DOE has transferred more than 30 sites, facilities or property rights (e.g., easements) to other federal agencies, tribal nations, local governments, and private companies. LM is responsible for nearly 13,000 acres of the DOE's land

  17. Rates Meetings and Workshops (pbl/rates)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rate Case Workshops Other Power Rates-Related Workshops July 1, 2004 - Rates and Finances Workshop (updated June 25, 2004) (financial and rate forecasts and scenarios for FY...

  18. Asset Score Webinar Slides: Real Estate and Design Professionals |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Real Estate and Design Professionals Asset Score Webinar Slides: Real Estate and Design Professionals The Asset Score is a free, web-based software tool developed by DOE and the Pacific Northwest National Laboratory (PNNL) that assesses the physical and structural energy efficiency of commercial and multifamily residential buildings. It generates a simple energy efficiency rating that enables comparison among buildings, and identifies custom opportunities to invest in

  19. Building Energy Asset Score: Real Estate Managers | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Estate Managers Building Energy Asset Score: Real Estate Managers The U.S. Department of Energy's Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. View

  20. Real-Time Benchmark Suite

    Energy Science and Technology Software Center (OSTI)

    1992-01-17

    This software provides a portable benchmark suite for real time kernels. It tests the performance of many of the system calls, as well as the interrupt response time and task response time to interrupts. These numbers provide a baseline for comparing various real-time kernels and hardware platforms.

  1. Federal Real Property Council Guidance

    Office of Environmental Management (EM)

    Federal Real Property Council Guidance for Improved Asset Management December 22, 2004 Federal Real Property Council Guidance for Improved Asset Management Table of Contents I. Overview............................................................................. 1 II. Guiding Principles .................................................................... 3 III. Asset Management Plan - Required Components............................... 4 IV. Asset Management Plan - "Shelf

  2. Towards a Real-Time Cluster Computing Infrastructure

    SciTech Connect (OSTI)

    Hui, Peter SY; Chikkagoudar, Satish; Chavarría-Miranda, Daniel; Johnston, Mark R.

    2011-11-01

    Real-time computing has traditionally been considered largely in the context of single-processor and embedded systems, and indeed, the terms real-time computing, embedded systems, and control systems are often mentioned in closely related contexts. However, real-time computing in the context of multinode systems, specifically high-performance, cluster-computing systems, remains relatively unexplored, largely due to the fact that until now, there has not been a need for such an environment. In this paper, we motivate the need for a cluster computing infrastructure capable of supporting computation over large datasets in real-time. Our motivating example is an analytical framework to support the next generation North American power grid, which is growing both in size and complexity. With streaming sensor data in the future power grid potentially reaching rates on the order of terabytes per day, the task of analyzing this data subject to real-time guarantees becomes a daunting task which will require the power of high-performance cluster computing capable of functioning under real-time constraints. One specific challenge that such an environment presents is the need for real-time networked communication between cluster nodes. In this paper, we discuss the need for real-time high-performance cluster computation, along with our work-in-progress towards an infrastructure which will ultimately enable such an environment.

  3. Radiation Levels in Real Time?

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Levels in Real Time? There's an App for That Gamma radiation levels in the southern Nevada area will soon be accessible around the world at the touch of a finger. Makers of the ...

  4. Distributed H{sub 2} Supply for Fuel Cell Utility Vehicles Year 6 - Activity 3.5 - Development fo a National Center for Hydrogen Technology

    SciTech Connect (OSTI)

    Almlie, Jay

    2012-04-15

    The Energy & Environmental Research Center (EERC) has developed a high-pressure hydrogen production system that reforms a liquid organic feedstock and water at operating pressures up to 800 bar (~12,000 psig). The advantages of this system include the elimination of energy-intensive hydrogen compression, a smaller process footprint, and the elimination of gaseous or liquid hydrogen transport. This system could also potentially enable distributed hydrogen production from centralized coal. Processes have been investigated to gasify coal and then convert the syngas into alcohol or alkanes. These alcohols and alkanes could then be easily transported in bulk to distributed high-pressure water-reforming (HPWR)-based systems to deliver hydrogen economically. The intent of this activity was to utilize the EERC’s existing HPWR hydrogen production process, previously designed and constructed in a prior project phase, as a basis to improve operational and production performance of an existing demonstration unit. Parameters to be pursued included higher hydrogen delivery pressure, higher hydrogen production rates, and the ability to refill within a 5-minute time frame.

  5. Current BPA Power Rates (pbl/rates)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and Workshops WP-10 Rate Case WP-07 Rate Case WP-07 Supplemental Rate Case ASC Methodology Adjustments (2007-2009) Adjustments (2002-2006) Previous Rate Cases Financial...

  6. Power Rates Announcements (pbl/rates)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    WP-10 Rate Case WP-07 Rate Case WP-07 Supplemental Rate Case ASC Methodology Adjustments (2007-2009) Adjustments (2002-2006) Previous Rate Cases Financial Choices (2003-06) Power...

  7. REAL ESTATE PROCESS | Department of Energy

    Office of Environmental Management (EM)

    REAL ESTATE PROCESS REAL ESTATE PROCESS PDF icon Table of Contents.pdf PDF icon Real Estate Process.pdf More Documents & Publications dg_appendices.pdf Site Selection Process Project Management Quality Assurance Guide, GPG 017

  8. Colonia Real Estate | Open Energy Information

    Open Energy Info (EERE)

    Estate Jump to: navigation, search Name: Colonia Real Estate Place: Germany Product: German property developer. References: Colonia Real Estate1 This article is a stub. You can...

  9. Real Goods Solar Ukiah | Open Energy Information

    Open Energy Info (EERE)

    navigation, search Logo: Real Goods Solar Ukiah Name: Real Goods Solar Ukiah Address: 301 L Kunzler Ranch Rd Place: Ukiah, California Zip: 95482 Sector: Solar Year Founded: 1978...

  10. Real Goods Solar Campbell | Open Energy Information

    Open Energy Info (EERE)

    Goods Solar Campbell Jump to: navigation, search Logo: Real Goods Solar Campbell Name: Real Goods Solar Campbell Address: 1624 Dell Avenue Place: Campbell, California Zip: 95008...

  11. Current Power Rates

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    links Financial Information Financial Public Processes Asset Management Cost Verification Process Rate Cases Rate Information Current Power Rates Current Transmission Rates...

  12. Current Transmission Rates

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    links Financial Information Financial Public Processes Asset Management Cost Verification Process Rate Cases Rate Information Current Power Rates Current Transmission Rates...

  13. Previous Power Rates

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    links Financial Information Financial Public Processes Asset Management Cost Verification Process Rate Cases Rate Information Current Power Rates Current Transmission Rates...

  14. Previous Transmission Rates

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    links Financial Information Financial Public Processes Asset Management Cost Verification Process Rate Cases Rate Information Current Power Rates Current Transmission Rates...

  15. Real Property and Asset Management

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2003-09-24

    The directive establishes an integrated corporate-level, performance based approach to the life-cycle management of our real property assets. It links real property asset planning, programming, budgeting and evaluation to the Department's multi-faceted missions. Successful implementation of this order will enable the Department to carry out stewardship responsibilities, and will ensure that facilities and infrastructure are properly sized and in a condition to meet our mission requirements today and in the future. Supersedes DOE O 430.1A Chg 1.

  16. DISPOSAL OF EXCESS REAL PROPERTY

    Office of Legacy Management (LM)

    . . : '* FEB 1972. : . .. - .. ..' *. ,; --.. . *..,,, :. :-, -, ' :.: t:-,...: : ,. -.". .- v ;; -'.1.;, ; . , DISPOSAL OF EXCESS REAL PROPERTY PARCEL 228 " . ;: 'i: .-. ' ' . -- - , *: , ; b;- .;.= ' i .; ,s ' ; .: '- :. ,S,, - ; * ^. ',. *. ;;: : ' " . - .. ,'~', approval is requested to report as excess a 20-acre;tract of landand improvements. The tract is located within the Oak Ridge comnunity near the intersection of Melton Lake Drive and the Oak Ridge Turnpike and is

  17. PNCA-02 Rate Case (rates/ratecases)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Proposed Adjustment to the Rate for Interchange Energy Imbalances Under the Pacific Northwest Coordination Agreement (PNCA-02 Rate Case) (updated on April 26, 2002) BPA has issued...

  18. Join the Commercial Real Estate Energy Alliance

    SciTech Connect (OSTI)

    2009-03-01

    This fact sheet describes the Commercial Real Estate Energy Alliance, it's membership, and activities.

  19. 2015 Federal Real Property Council Reporting Guidance

    Broader source: Energy.gov [DOE]

    Executive Order (EO) 13327, “Federal Real Property Asset Management,” was created to promote efficient and economical use of the Federal Government’s real property assets. The EO established the interagency Federal Real Property Council (FRPC), the role of the Senior Real Property Officer (SRPO), and the mandated creation of a centralized real property database. Issued by the FRPC and pursuant to EO 13327,1 the Guidance for Real Property Inventory Reporting represents the Federal real property reporting guidelines for agencies. This 2015 version reflects changes and additions to the data elements as approved by the FRPC.

  20. Letter fo Support from Research Mentor

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    See Research Proposals for detailed information about the research proposal requirements. Yes ... Training activities may include but not limited to preparation of grant proposals, ...

  1. MHK Technologies/FO | Open Energy Information

    Open Energy Info (EERE)

    here Point Absorber Technology Readiness Level Click here TRL 1-3: Discovery Concept Definition Early Stage Development & Design & Engineering Technology Description The...

  2. Large Scale Evaluation fo Nickel Aluminide Rolls

    SciTech Connect (OSTI)

    2005-09-01

    This completed project was a joint effort between Oak Ridge National Laboratory and Bethlehem Steel (now Mittal Steel) to demonstrate the effectiveness of using nickel aluminide intermetallic alloy rolls as part of an updated, energy-efficient, commercial annealing furnace system.

  3. Dynamic Line Rating: Research and Policy Evaluation

    SciTech Connect (OSTI)

    Jake P. Gentle; Kurt S. Myers; Michael R. West

    2014-07-01

    Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of electrical conductors to be increased based on local weather conditions. Overhead lines are conventionally given a conservative rating based on worst case scenarios. We demonstrate that observing the conditions in real time leads to additional capacity and safer operation. This paper provides a report of a pioneering scheme in the United States of America in which DLR has been applied. Thereby, we demonstrate that observing the local weather conditions in real time leads to additional capacity and safer operation. Secondly, we discuss limitations involved. In doing so, we arrive at novel insights which will inform and improve future DLR projects. Third, we provide a policy background and discussion to clarify the technology’s potential and identifies barriers to the imminent adoption of dynamic line rating systems. We provide suggestions for regulatory bodies about possible improvements in policy to encourage adoption of this beneficial technology.

  4. Radiation Levels in Real Time?

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Levels in Real Time? There's an App for That! Gamma radiation levels in the southern Nevada area will soon be accessible around the world at the touch of a finger. Makers of the cell phone application EcoData: Radiation are expanding their global network of radiation monitoring stations to include up-to-date readings from the Community Environmental Monitoring Program (CEMP) based out of southern Nevada. The CEMP was established in 1981 to monitor manmade and natural radiation levels surrounding

  5. Building America: Making Real Progress

    Energy Savers [EERE]

    America: Making Real Progress for U.S. Homes The U.S. Department of Energy (DOE) Building America Program conducts innovative housing research on energy efficiency to benefit the residential building industry and the public. The program has produced more than 100 innovations and accel- erated the adoption of energy-saving technologies. Since 1995, this work has helped households across the nation save up to $54 billion and avoid the emissions of 500 million tons of carbon dioxide. DOE esti-

  6. Rate Case Elements

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Proceeding Rate Information Residential Exchange Program Surplus Power Sales Reports Rate Case Elements BPA's rate cases are decided "on the record." That is, in making a decision...

  7. Power Rate Cases (pbl/rates)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Choices (2003-06) Power Function Review (PFR) Firstgov Power Rate Cases BPA's wholesale power rates are set to recover its costs and repay the U.S. Treasury for the Federal...

  8. Chlorite Dissolution Rates

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Carroll, Susan

    2013-07-01

    Spreadsheets provides measured chlorite rate data from 100 to 300C at elevated CO2. Spreadsheet includes derived rate equation.

  9. Chlorite Dissolution Rates

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Carroll, Susan

    Spreadsheets provides measured chlorite rate data from 100 to 300C at elevated CO2. Spreadsheet includes derived rate equation.

  10. 2013 Real Property Desk Guide | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Property Desk Guide 2013 Real Property Desk Guide PDF icon Real Estate Desk Guide - 2013 update.pdf More Documents & Publications REAL ESTATE PROPERTY GUIDE 2014 REAL ESTATE PROPERTY GUIDE 2013 OPAM Policy Acquisition Guides

  11. REAL ESTATE PROPERTY GUIDE 2014 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    4 REAL ESTATE PROPERTY GUIDE 2014 PDF icon Real Estate Desk Guide - 2014 update.pdf More Documents & Publications 2013 Real Property Desk Guide REAL ESTATE PROPERTY GUIDE 2013 2015 Federal Real Property Council Reporting Guidance

  12. Real Goods Solar Denver | Open Energy Information

    Open Energy Info (EERE)

    Real Goods Solar Denver Name: Real Goods Solar Denver Address: 7003 E. 47th Ave Dr, Unit 700 Place: Denver, Colorado Zip: 80218 Sector: Solar Year Founded: 1978 Phone Number:...

  13. Bully Real Estate AS | Open Energy Information

    Open Energy Info (EERE)

    Real Estate AS Jump to: navigation, search Name: Bully Real Estate AS Place: Praha 2, Czech Republic Zip: 120 00 Product: Czech Republic-based company going ahead as a...

  14. Working with the Real Estate Sector

    Broader source: Energy.gov [DOE]

    Better Buildings Neighborhood Program Workforce Peer Exchange Call: Working with the Real Estate Sector, Call Slides and Discussion Summary, March 1, 2012. This call discussed effective strategies for working with the real estate sector.

  15. Real time infrared aerosol analyzer

    DOE Patents [OSTI]

    Johnson, Stanley A. (Countryside, IL); Reedy, Gerald T. (Bourbonnais, IL); Kumar, Romesh (Naperville, IL)

    1990-01-01

    Apparatus for analyzing aerosols in essentially real time includes a virtual impactor which separates coarse particles from fine and ultrafine particles in an aerosol sample. The coarse and ultrafine particles are captured in PTFE filters, and the fine particles impact onto an internal light reflection element. The composition and quantity of the particles on the PTFE filter and on the internal reflection element are measured by alternately passing infrared light through the filter and the internal light reflection element, and analyzing the light through infrared spectrophotometry to identify the particles in the sample.

  16. Real time analysis under EDS

    SciTech Connect (OSTI)

    Schneberk, D.

    1985-07-01

    This paper describes the analysis component of the Enrichment Diagnostic System (EDS) developed for the Atomic Vapor Laser Isotope Separation Program (AVLIS) at Lawrence Livermore National Laboratory (LLNL). Four different types of analysis are performed on data acquired through EDS: (1) absorption spectroscopy on laser-generated spectral lines, (2) mass spectrometer analysis, (3) general purpose waveform analysis, and (4) separation performance calculations. The information produced from this data includes: measures of particle density and velocity, partial pressures of residual gases, and overall measures of isotope enrichment. The analysis component supports a variety of real-time modeling tasks, a means for broadcasting data to other nodes, and a great degree of flexibility for tailoring computations to the exact needs of the process. A particular data base structure and program flow is common to all types of analysis. Key elements of the analysis component are: (1) a fast access data base which can configure all types of analysis, (2) a selected set of analysis routines, (3) a general purpose data manipulation and graphics package for the results of real time analysis. Each of these components are described with an emphasis upon how each contributes to overall system capability. 3 figs.

  17. Real Time Pricing and the Real Live Firm

    SciTech Connect (OSTI)

    Moezzi, Mithra; Goldman, Charles; Sezgen, Osman; Bharvirkar, Ranjit; Hopper, Nicole

    2004-05-26

    Energy economists have long argued the benefits of real time pricing (RTP) of electricity. Their basis for modeling customers response to short-term fluctuations in electricity prices are based on theories of rational firm behavior, where management strives to minimize operating costs and optimize profit, and labor, capital and energy are potential substitutes in the firm's production function. How well do private firms and public sector institutions operating conditions, knowledge structures, decision-making practices, and external relationships comport with these assumptions and how might this impact price response? We discuss these issues on the basis of interviews with 29 large (over 2 MW) industrial, commercial, and institutional customers in the Niagara Mohawk Power Corporation service territory that have faced day-ahead electricity market prices since 1998. We look at stories interviewees told about why and how they respond to RTP, why some customers report that they can't, and why even if they can, they don't. Some firms respond as theorized, and we describe their load curtailment strategies. About half of our interviewees reported that they were unable to either shift or forego electricity consumption even when prices are high ($0.50/kWh). Reasons customers gave for why they weren't price-responsive include implicit value placed on reliability, pricing structures, lack of flexibility in adjusting production inputs, just-in-time practices, perceived barriers to onsite generation, and insufficient time. We draw these observations into a framework that could help refine economic theory of dynamic pricing by providing real-world descriptions of how firms behave and why.

  18. BP-18 Rate Proceeding

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Skip navigation links Financial Information Financial Public Processes Asset Management Cost Verification Process Rate Cases BP-18 Rate Case Related Publications Meetings...

  19. BP-12 Rate Case

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Skip navigation links Financial Information Financial Public Processes Asset Management Cost Verification Process Rate Cases BP-18 Rate Case Related Publications Meetings...

  20. BP-16 Rate Case

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Skip navigation links Financial Information Financial Public Processes Asset Management Cost Verification Process Rate Cases BP-18 Rate Case Related Publications Meetings...

  1. Before a Rate Case

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    links Financial Information Financial Public Processes Asset Management Cost Verification Process Rate Cases BP-18 Rate Case Related Publications Meetings and Workshops Customer...

  2. Rating Agency Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Liabilities Financial Plan Financial Public Processes Asset Management Cost Verification Process Rate Cases Rate Information Residential Exchange Program Surplus Power Sales...

  3. 2012 Transmission Rate Schedules

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2014 Transmission, Ancillary, and Control Area Service Rate Schedules and General Rate Schedule Provisions (FY 2014-2015) October 2013 United States Department of Energy...

  4. Business Models Guide: Real Estate Agent | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Models Guide: Real Estate Agent Business Models Guide: Real Estate Agent With excellent ... PDF icon Business Models Guide: Real Estate Agent More Documents & Publications Working ...

  5. Evaluation of Instrumentation and Dynamic Thermal Ratings for Overhead Lines

    SciTech Connect (OSTI)

    Phillips, A.

    2013-01-31

    In 2010, a project was initiated through a partnership between the Department of Energy (DOE) and the New York Power Authority (NYPA) to evaluate EPRI?s rating technology and instrumentation that can be used to monitor the thermal states of transmission lines and provide the required real-time data for real-time rating calculations. The project included the installation and maintenance of various instruments at three 230 kV line sites in northern New York. The instruments were monitored, and data collection and rating calculations were performed for about a three year period.

  6. Student's algorithm solves real-world problem

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Student's algorithm solves real-world problem Supercomputing Challenge: student's algorithm solves real-world problem Students learn how to use powerful computers to analyze, model, and solve real-world problems. April 3, 2012 Jordon Medlock of Albuquerque's Manzano High School won the 2012 Lab-sponsored Supercomputing Challenge Jordon Medlock of Albuquerque's Manzano High School won the 2012 Lab-sponsored Supercomputing Challenge by creating a computer algorithm that automates the process of

  7. AUDIT REPORT Bonneville Power Administration's Real Property...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    that Bonneville's Real Property Services management exerted pressure on appraisal staff to circumvent professional appraisal standards and created a difficult work environment. ...

  8. Real Goods Solar Fullerton | Open Energy Information

    Open Energy Info (EERE)

    Goods Solar Fullerton Name: Real Goods Solar Fullerton Address: 2466 E Fender Ave Unit F Place: Fullerton, California Zip: 92831 Sector: Solar Year Founded: 1989 Phone Number:...

  9. Acquisition, Use, and Disposal of Real Estate

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Acquisition of Capital Assets, or current version DOE Order 430.1B, Real Property Asset Management, or current version Overview This section provides internal Departmental ...

  10. Real States EOOD | Open Energy Information

    Open Energy Info (EERE)

    real estate company active in PV project development. Coordinates: 42.697085, 23.32455 Show Map Loading map... "minzoom":false,"mappingservice":"googlemaps3","type":"...

  11. REAL ESTATE PROPERTY GUIDE 2014 | Department of Energy

    Energy Savers [EERE]

    REAL ESTATE PROPERTY GUIDE 2014 PDF icon Real Estate Desk Guide - 2014 update.pdf More Documents & Publications 2013 Real Property Desk Guide REAL ESTATE PROPERTY GUIDE 2013 OPAM ...

  12. REAL ESTATE PROPERTY GUIDE 2013 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    3 REAL ESTATE PROPERTY GUIDE 2013 PDF icon Real Estate Desk Guide - 2013 update.pdf More Documents & Publications REAL ESTATE PROPERTY GUIDE 2014 2013 Real Property Desk Guide OPAM Policy Acquisition Guides

  13. Solar Real-Time Pricing: Is Real-Time Electricity Pricing Beneficial...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Solar Real-Time Pricing: Is Real-Time Electricity Pricing Beneficial to Solar PV in New ... Location New York, New York United States See map: Google Maps Date July 2009 Topic ...

  14. Fact #696: October 10, 2011 Top Ten "Real World" Fuel Economy Leaders |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy 6: October 10, 2011 Top Ten "Real World" Fuel Economy Leaders Fact #696: October 10, 2011 Top Ten "Real World" Fuel Economy Leaders The Environmental Protection Agency (EPA) fuel economy ratings on the window stickers of new cars are based on strict test cycles conducted in a controlled laboratory setting. These official EPA estimates do not reflect all the varied conditions encountered in real world driving such as congestion, terrain, weather,

  15. Senior Real Property Officer (SRPO) Responsibilities About Senior Real Property Officers (SRPO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Senior Real Property Officer (SRPO) Responsibilities About Senior Real Property Officers (SRPO) The SRPO is a senior-level manager who develops and implements agency asset management plans. The SRPO is responsible for ensuring that the asset management plan meets the following requirements: Identify and categorize real property owned, leased, or managed by the SRPO's agency Identify and pursue goals with appropriate deadlines for real property and measure agency progress Prioritize actions to be

  16. Business Models Guide: Real Estate Agent | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Models Guide: Real Estate Agent Business Models Guide: Real Estate Agent With excellent marketing skills, a keen understanding of financing options, and a broad knowledge of the industry, real estate agents are natural advocates for smart energy efficiency upgrades. PDF icon Business Models Guide: Real Estate Agent More Documents & Publications Working with the Real Estate Sector Business Models and Case Examples for Working with the Real Estate Sector Trends in Real Estate and Energy

  17. Real time sensor for therapeutic radiation delivery

    DOE Patents [OSTI]

    Bliss, M.; Craig, R.A.; Reeder, P.L.

    1998-01-06

    The invention is a real time sensor for therapeutic radiation. A probe is placed in or near the patient that senses in real time the dose at the location of the probe. The strength of the dose is determined by either an insertion or an exit probe. The location is determined by a series of vertical and horizontal sensing elements that gives the operator a real time read out dose location relative to placement of the patient. The increased accuracy prevents serious tissue damage to the patient by preventing overdose or delivery of a dose to a wrong location within the body. 14 figs.

  18. Real time sensor for therapeutic radiation delivery

    DOE Patents [OSTI]

    Bliss, Mary (West Richland, WA); Craig, Richard A. (West Richland, WA); Reeder, Paul L. (Richland, WA)

    1998-01-01

    The invention is a real time sensor for therapeutic radiation. A probe is placed in or near the patient that senses in real time the dose at the location of the probe. The strength of the dose is determined by either an insertion or an exit probe. The location is determined by a series of vertical and horizontal sensing elements that gives the operator a real time read out dose location relative to placement of the patient. The increased accuracy prevents serious tissue damage to the patient by preventing overdose or delivery of a dose to a wrong location within the body.

  19. Resonant thermonuclear reaction rate

    SciTech Connect (OSTI)

    Haubold, H.J.; Mathai, A.M.

    1986-08-01

    Basic physical principles for the resonant and nonresonant thermonuclear reaction rates are applied to find their standard representations for nuclear astrophysics. Closed-form representations for the resonant reaction rate are derived in terms of Meijer's G-italic-function. Analytic representations of the resonant and nonresonant nuclear reaction rates are compared and the appearance of Meijer's G-italic-function is discussed in physical terms.

  20. Improving Entrainment Rate Parameterization

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Entrainment Rate Parameterization For original submission and image(s), see ARM Research Highlights http://www.arm.gov/science/highlights/ Research Highlight Parameterization of entrainment rate is critical for improving representation of cloud- and convection-related processes in climate models; however, much remains unclear. This work seeks to improve understanding and parameterization of entrainment rate by use of aircraft observations and large-eddy simulations of shallow cumulus clouds over

  1. Real-time Pricing Demand Response in Operations

    SciTech Connect (OSTI)

    Widergren, Steven E.; Marinovici, Maria C.; Berliner, Teri; Graves, Alan

    2012-07-26

    AbstractDynamic pricing schemes have been implemented in commercial and industrial application settings, and recently they are getting attention for application to residential customers. Time-of-use and critical-peak-pricing rates are in place in various regions and are being piloted in many more. These programs are proving themselves useful for balancing energy during peak periods; however, real-time (5 minute) pricing signals combined with automation in end-use systems have the potential to deliver even more benefits to operators and consumers. Besides system peak shaving, a real-time pricing system can contribute demand response based on the locational marginal price of electricity, reduce load in response to a generator outage, and respond to local distribution system capacity limiting situations. The US Department of Energy (DOE) is teaming with a mid-west electricity service provider to run a distribution feeder-based retail electricity market that negotiates with residential automation equipment and clears every 5 minutes, thus providing a signal for lowering or raising electric consumption based on operational objectives of economic efficiency and reliability. This paper outlines the capability of the real-time pricing system and the operational scenarios being tested as the system is rolled-out starting in the first half of 2012.

  2. LCC Guidance Rates

    Broader source: Energy.gov [DOE]

    Notepad text file provides the LCC guidance rates in a numbered format for the various regions throughout the U.S.

  3. Draft Tiered Rate Methodology

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    For Regional Dialogue Discussion Purposes Only Pre-Decisional Draft Tiered Rates Methodology March 7, 2008 Pre-decisional, Deliberative, For Discussion Purposes Only March 7,...

  4. Monitoring external beam radiotherapy using real-time beam visualization

    SciTech Connect (OSTI)

    Jenkins, Cesare H.; Naczynski, Dominik J.; Yu, Shu-Jung S.; Xing, Lei

    2015-01-15

    Purpose: To characterize the performance of a novel radiation therapy monitoring technique that utilizes a flexible scintillating film, common optical detectors, and image processing algorithms for real-time beam visualization (RT-BV). Methods: Scintillating films were formed by mixing Gd{sub 2}O{sub 2}S:Tb (GOS) with silicone and casting the mixture at room temperature. The films were placed in the path of therapeutic beams generated by medical linear accelerators (LINAC). The emitted light was subsequently captured using a CMOS digital camera. Image processing algorithms were used to extract the intensity, shape, and location of the radiation field at various beam energies, dose rates, and collimator locations. The measurement results were compared with known collimator settings to validate the performance of the imaging system. Results: The RT-BV system achieved a sufficient contrast-to-noise ratio to enable real-time monitoring of the LINAC beam at 20 fps with normal ambient lighting in the LINAC room. The RT-BV system successfully identified collimator movements with sub-millimeter resolution. Conclusions: The RT-BV system is capable of localizing radiation therapy beams with sub-millimeter precision and tracking beam movement at video-rate exposure.

  5. REAL TIME SYSTEM OPERATIONS 2006-2007

    SciTech Connect (OSTI)

    Eto, Joseph H.; Parashar, Manu; Lewis, Nancy Jo

    2008-08-15

    The Real Time System Operations (RTSO) 2006-2007 project focused on two parallel technical tasks: (1) Real-Time Applications of Phasors for Monitoring, Alarming and Control; and (2) Real-Time Voltage Security Assessment (RTVSA) Prototype Tool. The overall goal of the phasor applications project was to accelerate adoption and foster greater use of new, more accurate, time-synchronized phasor measurements by conducting research and prototyping applications on California ISO's phasor platform - Real-Time Dynamics Monitoring System (RTDMS) -- that provide previously unavailable information on the dynamic stability of the grid. Feasibility assessment studies were conducted on potential application of this technology for small-signal stability monitoring, validating/improving existing stability nomograms, conducting frequency response analysis, and obtaining real-time sensitivity information on key metrics to assess grid stress. Based on study findings, prototype applications for real-time visualization and alarming, small-signal stability monitoring, measurement based sensitivity analysis and frequency response assessment were developed, factory- and field-tested at the California ISO and at BPA. The goal of the RTVSA project was to provide California ISO with a prototype voltage security assessment tool that runs in real time within California ISO?s new reliability and congestion management system. CERTS conducted a technical assessment of appropriate algorithms, developed a prototype incorporating state-of-art algorithms (such as the continuation power flow, direct method, boundary orbiting method, and hyperplanes) into a framework most suitable for an operations environment. Based on study findings, a functional specification was prepared, which the California ISO has since used to procure a production-quality tool that is now a part of a suite of advanced computational tools that is used by California ISO for reliability and congestion management.

  6. 2015 Federal Real Property Council Reporting Guidance | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy 2015 Federal Real Property Council Reporting Guidance 2015 Federal Real Property Council Reporting Guidance Real Property Reporting: EO 13327 requires agencies to report annually all owned, leased, and otherwise managed. Federal real property assets within and outside the United States, including improvements on Federal land. PDF icon 2015_Guidance_for_Real_Property_Inventory_Reporting__April_2015.pdf More Documents & Publications 2012 Federal Real Property Council Reporting

  7. 2007-2009 Power Rate Adjustments (pbl/rates)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Function Review (PFR) Firstgov FY 2007 2009 Power Rate Adjustments BPA's 2007-2009 Wholesale Power Rate Schedules and General Rate Schedule Provisions (GRSPs) took effect on...

  8. WP-07 Power Rate Case (rates/ratecases)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Meetings & Workshops Rate Case Parties Web Site WP-07 Supplemental Rate Case ASC Methodology Adjustments (2007-2009) Adjustments (2002-2006) Previous Rate Cases Financial...

  9. Comparison of Real World Energy Consumption to Models and DOE...

    Energy Savers [EERE]

    Comparison of Real World Energy Consumption to Models and DOE Test Procedures Comparison of Real World Energy Consumption to Models and DOE Test Procedures This study investigates ...

  10. Lean NOx Traps - Microstructural Studies of Real World and Model...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Traps - Microstructural Studies of Real World and Model Catalysts Lean NOx Traps - Microstructural Studies of Real World and Model Catalysts 2005 Diesel Engine Emissions Reduction...

  11. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Print Scientists have ... The ability to image the chemical reactions in living cells in real time, especially in ...

  12. Tracking Living Cells as They Differentiate in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Tracking Living Cells as They Differentiate in Real Time Print Protein phosphorylation ... cells, enabling them to follow cellular chemical changes in real time, without bias. ...

  13. Development of Real-Time, Gas Quality Sensor Technology - Fact...

    Broader source: Energy.gov (indexed) [DOE]

    project partners, will bring together real-time, gas quality sensor technology with ... PDF icon Development of Real-Time, Gas Quality Sensor Technology More Documents & ...

  14. Real Time Diagnostics for Algae-final-sm

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-time Monitoring And Diagnostics Detecting pathogens and predators to quickly recover ... Real-time Monitoring With Online Algal Reflectance Monitor System Researchers have ...

  15. Steps to Establish a Real-Time Transmission Monitoring System...

    Broader source: Energy.gov (indexed) [DOE]

    Steps to establish a real-time transmission monitoring system for transmission owners and ... Eastern and Western Interconnections real-time information on the functional status of ...

  16. Tracking Living Cells as They Differentiate in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Tracking Living Cells as They Differentiate in Real Time Tracking Living Cells as They Differentiate in Real Time Print Thursday, 27 September 2012 00:00 Protein phosphorylation ...

  17. Wireless technology collects real-time information from oil and...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Wireless technology collects real-time information from oil and gas wells Wireless technology collects real-time information from oil and gas wells The patented system delivers ...

  18. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Real-Time Chemical Imaging of Bacterial Biofilm Development Print Wednesday, 25 August 2010 00:00 Scientists have ...

  19. Development of Real-Time, Gas Quality Sensor Technology

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real-Time, Gas Quality Sensor Technology Introduction Landfll gas (LFG), composed largely ... By providing the capability for near real-time monitoring of the composition of these ...

  20. Competition Provides Students with Real-World Engineering Experience...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Competition Provides Students with Real-World Engineering Experience Competition Provides Students with Real-World Engineering Experience April 10, 2013 - 12:00am Addthis Fifteen...

  1. Vehicle Technologies Office Merit Review 2015: Analyzing Real...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Analyzing Real-World Light Duty Vehicle Efficiency Benefits Vehicle Technologies Office Merit Review 2015: Analyzing Real-World Light Duty Vehicle Efficiency Benefits Presentation ...

  2. FY 2013 Real Property Deferred, Actual, and Required Maintenance...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Property Deferred, Actual, and Required Maintenance Reporting Requirement FY 2013 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement PDF icon FY ...

  3. FY 2014 Real Property Data Related to Operations and Maintenance...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Property Data Related to Operations and Maintenance Guidance FY 2014 Real Property Data Related to Operations and Maintenance Guidance PDF icon FY2014DataRelatedtoOperati...

  4. FY 2012 Real Property Deferred, Actual, and Required Maintenance...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Property Deferred, Actual, and Required Maintenance Reporting Requirement FY 2012 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement PDF icon FY ...

  5. Working with Real Estate Home Inspectors, Exterminators, and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Working with Real Estate Home Inspectors, Exterminators, and Other "Nontraditional" Partners Working with Real Estate Home Inspectors, Exterminators, and Other "Nontraditional"...

  6. Guiding Principles of Real Property Asset Management | Department...

    Office of Environmental Management (EM)

    Guiding Principles of Real Property Asset Management Guiding Principles of Real Property Asset Management PDF icon frpcguidancefinal.pdf More Documents & Publications 2015...

  7. Capturing Energy Upgrades in the Real Estate Transaction | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Capturing Energy Upgrades in the Real Estate Transaction Capturing Energy Upgrades in the Real Estate Transaction Because green building techniques and products may impact the ...

  8. Real Goods Solar Santa Cruz | Open Energy Information

    Open Energy Info (EERE)

    Cruz Jump to: navigation, search Logo: Real Goods Solar Santa Cruz Name: Real Goods Solar Santa Cruz Address: 1115 Thompson Avenue, 1 Place: Santa Cruz, California Zip: 95062...

  9. Defining Real World Drive Cycles to Support APRF Technology Evaluation...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real World Drive Cycles to Support APRF Technology Evaluations Defining Real World Drive Cycles to Support APRF Technology Evaluations 2012 DOE Hydrogen and Fuel Cells Program and...

  10. Real Goods Solar San Rafael | Open Energy Information

    Open Energy Info (EERE)

    Rafael Jump to: navigation, search Logo: Real Goods Solar San Rafael Name: Real Goods Solar San Rafael Address: 27 Simms Street Place: San Rafael, California Zip: 94901 Sector:...

  11. Continuous, real time microwave plasma element sensor

    DOE Patents [OSTI]

    Woskov, P.P.; Smatlak, D.L.; Cohn, D.R.; Wittle, J.K.; Titus, C.H.; Surma, J.E.

    1995-12-26

    Microwave-induced plasma is described for continuous, real time trace element monitoring under harsh and variable conditions. The sensor includes a source of high power microwave energy and a shorted waveguide made of a microwave conductive, refractory material communicating with the source of the microwave energy to generate a plasma. The high power waveguide is constructed to be robust in a hot, hostile environment. It includes an aperture for the passage of gases to be analyzed and a spectrometer is connected to receive light from the plasma. Provision is made for real time in situ calibration. The spectrometer disperses the light, which is then analyzed by a computer. The sensor is capable of making continuous, real time quantitative measurements of desired elements, such as the heavy metals lead and mercury. 3 figs.

  12. Continuous, real time microwave plasma element sensor

    DOE Patents [OSTI]

    Woskov, Paul P. (4 Ledgewood Dr., Bedford, MA 01730); Smatlak, Donna L. (10 Village Hill Rd., Belmont, MA 02178); Cohn, Daniel R. (26 Walnut Hill Rd., Chestnut Hill, MA 02167); Wittle, J. Kenneth (1740 Conestoga Rd., Chester Springs, PA 19425); Titus, Charles H. (323 Echo Valley La., Newton Square, PA 19072); Surma, Jeffrey E. (806 Brian La., Kennewick, WA 99337)

    1995-01-01

    Microwave-induced plasma for continuous, real time trace element monitoring under harsh and variable conditions. The sensor includes a source of high power microwave energy and a shorted waveguide made of a microwave conductive, refractory material communicating with the source of the microwave energy to generate a plasma. The high power waveguide is constructed to be robust in a hot, hostile environment. It includes an aperture for the passage of gases to be analyzed and a spectrometer is connected to receive light from the plasma. Provision is made for real time in situ calibration. The spectrometer disperses the light, which is then analyzed by a computer. The sensor is capable of making continuous, real time quantitative measurements of desired elements, such as the heavy metals lead and mercury.

  13. Real-Time Occupancy Change Analyzer

    Energy Science and Technology Software Center (OSTI)

    2005-03-30

    The Real-Time Occupancy Change Analyzer (ROCA) produces an occupancy grid map of an environment around the robot, scans the environment to generate a current obstacle map relative to a current robot position, and converts the current obstacle map to a current occupancy grid map. Changes in the occupancy grid can be reported in real time to support a number of tracking capabilities. The benefit of ROCA is that rather than only providing a vector tomore » the detected change, it provides the actual x,y position of the change.« less

  14. Real Time Grid Reliability Management 2005

    SciTech Connect (OSTI)

    Eto, Joe; Eto, Joe; Lesieutre, Bernard; Lewis, Nancy Jo; Parashar, Manu

    2008-07-07

    The increased need to manage California?s electricity grid in real time is a result of the ongoing transition from a system operated by vertically-integrated utilities serving native loads to one operated by an independent system operator supporting competitive energy markets. During this transition period, the traditional approach to reliability management -- construction of new transmission lines -- has not been pursued due to unresolved issues related to the financing and recovery of transmission project costs. In the absence of investments in new transmission infrastructure, the best strategy for managing reliability is to equip system operators with better real-time information about actual operating margins so that they can better understand and manage the risk of operating closer to the edge. A companion strategy is to address known deficiencies in offline modeling tools that are needed to ground the use of improved real-time tools. This project: (1) developed and conducted first-ever demonstrations of two prototype real-time software tools for voltage security assessment and phasor monitoring; and (2) prepared a scoping study on improving load and generator response models. Additional funding through two separate subsequent work authorizations has already been provided to build upon the work initiated in this project.

  15. A monotonicity conjecture for real cubic maps

    SciTech Connect (OSTI)

    Dawson, S.P.; Galeeva, R.; Milnor, J.; Tresser, C.

    1993-12-01

    This will be an outline of work in progress. We study the conjecture that the topological entropy of a real cubic map depends ``monotonely`` on its parameters, in the sense that each locus of constant entropy in parameter space is a connected set. This material will be presented in more detail in a later paper.

  16. [FIXED RATE GUARANTEED OBLIGATIONS]

    Broader source: Energy.gov (indexed) [DOE]

    FIXED RATE GUARANTEED OBLIGATIONS] Draft Date: May 09, 2011 AMR-306688-v5 81-40475664 DATED AS OF [______], 20[__] AMONG THE HOLDERS IDENTIFIED HEREIN, THEIR SUCCESSORS AND PERMITTED ASSIGNS, AND THE UNITED STATES DEPARTMENT OF ENERGY, AS GUARANTOR, AND [_____________________________], AS ADMINISTRATIVE AGENT LOAN GUARANTEE AGREEMENT _____________________________ DOE FIPP Guarantee No. [______] ______________________________ AMR-306688-v5 - i - 81-40475664 CONTENTS Clause Page Section 1.

  17. FY 2014 Federal Real Property Reporting Requirement | Department of Energy

    Energy Savers [EERE]

    Federal Real Property Reporting Requirement FY 2014 Federal Real Property Reporting Requirement PDF icon FIMS FRPP FY 2014 Reporting Instructions Signed Sep 18 2014 .pdf More Documents & Publications Guidance for Fiscal Year 2015 Facilities Information Management System Data Validations FY09_Federal_Real_Property_Reporting_Requirements.pdf FY 2012 Federal Real Property Reporting Requirement

  18. Real Time Tailpipe Emission Measurements | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Time Tailpipe Emission Measurements Real Time Tailpipe Emission Measurements 2002 DEER Conference Presentation: Brookhaven National Laboratory PDF icon 2002_deer_imre.pdf More Documents & Publications Real-Time Simultaneous Measurements of Size, Density, and Composition of Single Ultrafine Diesel Tailpipe Particles Microsoft PowerPoint - 4. ORNL- deer.ppt [Read-Only] Real-Time Measurement of Diesel Trap Efficiency

  19. Acquisition, Use, and Disposal of Real Estate | Department of Energy

    Energy Savers [EERE]

    Acquisition, Use, and Disposal of Real Estate Acquisition, Use, and Disposal of Real Estate PDF icon Acquisition, Use, and Disposal of Real Estate More Documents & Publications Acquisition, Use, and Disposal of Real Estate OPAM Policy Acquisition Guides Chapter 17 - Special Contracting Methods

  20. Acquisition, Use, and Disposal of Real Estate | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Acquisition, Use, and Disposal of Real Estate Acquisition, Use, and Disposal of Real Estate PDF icon Acquisition, Use, and Disposal of Real Estate More Documents & Publications Acquisition, Use, and Disposal of Real Estate OPAM Policy Acquisition Guides Chapter 17 - Special Contracting Methods

  1. FY 2012 Real Property Deferred, Actual, and Required Maintenance Reporting

    Office of Environmental Management (EM)

    Requirement | Department of Energy Real Property Deferred, Actual, and Required Maintenance Reporting Requirement FY 2012 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement PDF icon FY 2012 DARM Transmittal Letter and Attachment Final.pdf More Documents & Publications FY 2013 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement Real Property Maintenance Reporting Requirement Memorandum (July 13, 2010)

  2. Rotational rate sensor

    DOE Patents [OSTI]

    Hunter, Steven L. (Livermore, CA)

    2002-01-01

    A rate sensor for angular/rotational acceleration includes a housing defining a fluid cavity essentially completely filled with an electrolyte fluid. Within the housing, such as a toroid, ions in the fluid are swept during movement from an excitation electrode toward one of two output electrodes to provide a signal for directional rotation. One or more ground electrodes within the housing serve to neutralize ions, thus preventing any effect at the other output electrode.

  3. Residential Solar Valuation Rates

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Residential Solar Valuation Rates Karl R. Rábago Rábago Energy LLC 1 The Ideal Residential Solar Tariff ‣ Fair to the utility and non-solar customers ‣ Fair compensation to the solar customer ‣ Decouple compensation from incentives ‣ Align public policy goals (decouple compensation from consumption) ‣ Intuitively sound and administratively simple 2 Historical Antecedents ‣ Externalities ‣ Price ≠ Cost ‣ Green Power ‣ Small Is Profitable (http://www.smallisprofitable.org/)

  4. [FLOATING RATE GUARANTEED OBLIGATIONS]

    Broader source: Energy.gov (indexed) [DOE]

    FLOATING RATE GUARANTEED OBLIGATIONS] Draft Date: May 09, 2011 AMR-306979-v3A 81-40475664 DATED AS OF [______], 20[__] AMONG THE HOLDERS IDENTIFIED HEREIN, THEIR SUCCESSORS AND PERMITTED ASSIGNS, AND THE UNITED STATES DEPARTMENT OF ENERGY, AS GUARANTOR, AND [_____________________________] AS ADMINISTRATIVE AGENT LOAN GUARANTEE AGREEMENT _____________________________ DOE FIPP Guarantee No. [______] ______________________________ AMR-306979-v3A - i - 81-40475664 CONTENTS Clause Page Section 1.

  5. Technical Qualifications for Treating Photovoltaic Assets as Real Property by Real Estate Investment Trusts (REITs)

    SciTech Connect (OSTI)

    Feldman, D.; Mendelsohn, M.; Coughlin, J.

    2012-06-01

    It has been proposed that Real Estate Investment Trusts (REITs) have the potential to lower the cost and increase the adoption of photovoltaic systems (PV) by offering a more attractive source of capital. The purpose of this paper is to explain the fundamental physical characteristics of PV and compare them to the characteristics of 'real' property, to help determine whether REITs can own PV systems.

  6. Real time gamma-ray signature identifier

    DOE Patents [OSTI]

    Rowland, Mark (Alamo, CA); Gosnell, Tom B. (Moraga, CA); Ham, Cheryl (Livermore, CA); Perkins, Dwight (Livermore, CA); Wong, James (Dublin, CA)

    2012-05-15

    A real time gamma-ray signature/source identification method and system using principal components analysis (PCA) for transforming and substantially reducing one or more comprehensive spectral libraries of nuclear materials types and configurations into a corresponding concise representation/signature(s) representing and indexing each individual predetermined spectrum in principal component (PC) space, wherein an unknown gamma-ray signature may be compared against the representative signature to find a match or at least characterize the unknown signature from among all the entries in the library with a single regression or simple projection into the PC space, so as to substantially reduce processing time and computing resources and enable real-time characterization and/or identification.

  7. Visualizations for Real-time Pricing Demonstration

    SciTech Connect (OSTI)

    Marinovici, Maria C.; Hammerstrom, Janelle L.; Widergren, Steven E.; Dayley, Greg K.

    2014-10-13

    In this paper, the visualization tools created for monitoring the operations of a real-time pricing demonstration system that runs at a distribution feeder level are presented. The information these tools provide gives insights into demand behavior from automated price responsive devices, distribution feeder characteristics, impact of weather on system’s development, and other significant dynamics. Given the large number of devices that bid into a feeder-level real-time electricity market, new techniques are explored to summarize the present state of the system and contrast that with previous trends as well as future projections. To better understand the system behavior and correctly inform decision-making procedures, effective visualization of the data is imperative.

  8. Performance bound for real OTEC heat engines

    SciTech Connect (OSTI)

    Wu, C.

    1987-01-01

    Maximum power and efficiency at the maximum power of an irreversible OTEC heat engine are treated. When time is explicitly considered in the energy exchanges between the heat engine and its surroundings, it is found that there is a bound on the efficiency of the real OTEC heat engine at the maximum power condition. This bound can guide the evaluation of existing OTEC systems or influence design of future OTEC heat engines.

  9. Writing Effective Initial Summary Ratings Initial Summary Rating (ISR)

    Broader source: Energy.gov (indexed) [DOE]

    Initial Summary Ratings Initial Summary Rating (ISR) At the end of the performance cycle, the rating official must prepare an ISR in ePerformance for each SES member who has completed at least 90 days on an established performance plan. Rating officials must take into account the SES member's accomplishments achieved during the performance cycle and the impact to the organization's performance. Rating officials must appraise executives realistically and fairly and avoid ratings inflation.

  10. Rail Coal Transportation Rates

    Gasoline and Diesel Fuel Update (EIA)

    reports Coal Transportation Rates to the Electric Power Sector With Data through 2014 | Release Date: February 23, 2016 | Next Release Date: January 2017 | Previous Data Years Year: 2013 2011 2010 2008 2002 Go Background and Methodology The data in the tables are based on primary data collected by EIA from plant owners and operators on the Form EIA-923, "Power Plant Operations Report" (EIA-923 Data) and supplement data and analysis of coal transportation costs released by EIA in June

  11. October 1996 - September 2001 Wholesale Power Rates (rates/previous...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    affecting a specific power purchase. For more specific information see: 1996 Final Wholesale Power and Transmission Rate Schedules: Power Rates (PDF, 84 pages, 188 kb) Ancillary...

  12. Rate Schedules | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Rate Schedules Rate Schedules One of the major responsibilities of Southeastern is to design, formulate, and justify rate schedules. Repayment studies prepared by the agency determine revenue requirements and appropriate rate levels and these studies for each of Southeastern's four power marketing systems are updated annually. They demonstrate the adequacy of the rates for each system. Rates are considered to be adequate when revenues are sufficient to repay all costs associated with power

  13. Real-time soft tissue motion estimation for lung tumors during radiotherapy delivery

    SciTech Connect (OSTI)

    Rottmann, Joerg; Berbeco, Ross; Keall, Paul

    2013-09-15

    Purpose: To provide real-time lung tumor motion estimation during radiotherapy treatment delivery without the need for implanted fiducial markers or additional imaging dose to the patient.Methods: 2D radiographs from the therapy beam's-eye-view (BEV) perspective are captured at a frame rate of 12.8 Hz with a frame grabber allowing direct RAM access to the image buffer. An in-house developed real-time soft tissue localization algorithm is utilized to calculate soft tissue displacement from these images in real-time. The system is tested with a Varian TX linear accelerator and an AS-1000 amorphous silicon electronic portal imaging device operating at a resolution of 512 × 384 pixels. The accuracy of the motion estimation is verified with a dynamic motion phantom. Clinical accuracy was tested on lung SBRT images acquired at 2 fps.Results: Real-time lung tumor motion estimation from BEV images without fiducial markers is successfully demonstrated. For the phantom study, a mean tracking error <1.0 mm [root mean square (rms) error of 0.3 mm] was observed. The tracking rms accuracy on BEV images from a lung SBRT patient (≈20 mm tumor motion range) is 1.0 mm.Conclusions: The authors demonstrate for the first time real-time markerless lung tumor motion estimation from BEV images alone. The described system can operate at a frame rate of 12.8 Hz and does not require prior knowledge to establish traceable landmarks for tracking on the fly. The authors show that the geometric accuracy is similar to (or better than) previously published markerless algorithms not operating in real-time.

  14. Property:OpenEI/UtilityRate/EnergyRateStructure/Tier5Rate | Open...

    Open Energy Info (EERE)

    Property Edit with form History Facebook icon Twitter icon Property:OpenEIUtilityRateEnergyRateStructureTier5Rate Jump to: navigation, search This is a property of type...

  15. Property:OpenEI/UtilityRate/DemandRateStructure/Tier1Rate | Open...

    Open Energy Info (EERE)

    Property Edit with form History Facebook icon Twitter icon Property:OpenEIUtilityRateDemandRateStructureTier1Rate Jump to: navigation, search This is a property of type...

  16. Property:OpenEI/UtilityRate/DemandRateStructure/Tier3Rate | Open...

    Open Energy Info (EERE)

    Property Edit with form History Facebook icon Twitter icon Property:OpenEIUtilityRateDemandRateStructureTier3Rate Jump to: navigation, search This is a property of type...

  17. Property:OpenEI/UtilityRate/EnergyRateStructure/Tier3Rate | Open...

    Open Energy Info (EERE)

    Property Edit with form History Facebook icon Twitter icon Property:OpenEIUtilityRateEnergyRateStructureTier3Rate Jump to: navigation, search This is a property of type...

  18. Property:OpenEI/UtilityRate/EnergyRateStructure/Tier4Rate | Open...

    Open Energy Info (EERE)

    Property Edit with form History Facebook icon Twitter icon Property:OpenEIUtilityRateEnergyRateStructureTier4Rate Jump to: navigation, search This is a property of type...

  19. Figure ES2. Annual Indices of Real Disposable Income, Vehicle...

    U.S. Energy Information Administration (EIA) Indexed Site

    ES2 Figure ES2. Annual Indices of Real Disposable Income, Vehicle-Miles Traveled, Consumer Price Index (CPI-U), and Real Average Retail Gasoline Price, 1978-2004, 1985100...

  20. Forming rotated SAR images by real-time motion compensation....

    Office of Scientific and Technical Information (OSTI)

    Forming rotated SAR images by real-time motion compensation. Citation Details In-Document Search Title: Forming rotated SAR images by real-time motion compensation. Proper waveform...

  1. Autonomous global sky monitoring with real-time robotic follow...

    Office of Scientific and Technical Information (OSTI)

    Conference: Autonomous global sky monitoring with real-time robotic follow-up Citation Details In-Document Search Title: Autonomous global sky monitoring with real-time robotic...

  2. Looking at Transistor Gate Oxide Formation in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Looking at Transistor Gate Oxide Formation in Real Time Print The oxide gate layer is ... Now, for the first time, a group of researchers has obtained real-time oxidation results ...

  3. Real-Time Quantitative Imaging of Failure Events in Materials...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Quantitative Imaging of Failure Events in Materials Under Load at Temperatures Above 1,600 C Real-Time Quantitative Imaging of Failure Events in Materials Under Load at ...

  4. Ames Lab 101: Real-Time 3D Imaging

    ScienceCinema (OSTI)

    Zhang, Song

    2012-08-29

    Ames Laboratory scientist Song Zhang explains his real-time 3-D imaging technology. The technique can be used to create high-resolution, real-time, precise, 3-D images for use in healthcare, security, and entertainment applications.

  5. HEAVY-DUTY TRUCK EMISSIONS AND FUEL CONSUMPTION SIMULATING REAL...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    HEAVY-DUTY TRUCK EMISSIONS AND FUEL CONSUMPTION SIMULATING REAL-WORLD DRIVING IN LABORATORY CONDITIONS HEAVY-DUTY TRUCK EMISSIONS AND FUEL CONSUMPTION SIMULATING REAL-WORLD DRIVING ...

  6. 17.3 - Acquisition, Use and Disposal of Real Property

    Broader source: Energy.gov (indexed) [DOE]

    and Disposal of Real Estate DOE Directives DOE Order 413.3B, Program and Project Management for the Acquisition of Capital Assets, or current version DOE Order 430.1B, Real...

  7. The Department's real property assets are vital to the accomplishment...

    Energy Savers [EERE]

    The Department&8217;s real property assets are vital to the accomplishment of its mission The Department&8217;s real property assets are vital to the accomplishment of its...

  8. American Road: Clean Diesels for the Real World | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    American Road: Clean Diesels for the Real World American Road: Clean Diesels for the Real World Perspectives on clean diesels and public policy as it is developing in the US, as...

  9. The Department's real property assets are vital to the accomplishment...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    .........1 Facilities Planning Process......first ever "Green Day" with several expert speakers from outside of DOE. Real ...

  10. Trends in Real Estate and Energy Efficiency | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Efficiency Trends in Real Estate and Energy Efficiency Better Buildings Residential Network Peer Exchange Call Series: Trends in Real Estate and Energy Efficiency, call slides and discussion summary, January 22, 2015. PDF icon Call Slides and Discussion Summary More Documents & Publications DOE ZERH Webinar: Sales and Value Recognition of ZERH Working with the Real Estate Sector Mastermind Session: Connecting the Dots Between the Real Estate Market and Residential Energy Efficiency

  11. Jefferson Lab experiment works to clarify Real Compton Scattering |

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Jefferson Lab Real Compton Scattering experiment spokespeople The Real Compton Scattering experiment spokespeople take a short break for a photo. From left is Bogdan Wojtsekhowski, JLab staff scientist; Charles Hyde-Wright, physics professor at Old Dominion University; and Alan Nathan, physics professor at the University of Illinois and chair of the JLab Users Group. Jefferson Lab experiment works to clarify Real Compton Scattering January 27, 2003 Jefferson Lab's Real Compton Scattering

  12. FY 2013 Real Property Deferred, Actual, and Required Maintenance Reporting

    Office of Environmental Management (EM)

    Requirement | Department of Energy Real Property Deferred, Actual, and Required Maintenance Reporting Requirement FY 2013 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement PDF icon FY 2013 DARM Transmittal Letter and Attachment Final.pdf More Documents & Publications FY 2012 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement FY_09_DM_RM_AM_Reporting_Memo_and_attachment_072009.pdf Real Property Maintenance Reporting Requirement

  13. 2012 Federal Real Property Council Reporting Guidance | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy 2 Federal Real Property Council Reporting Guidance 2012 Federal Real Property Council Reporting Guidance PDF icon FRPP 2012 Data Dictionary FINAL.pdf More Documents & Publications 2015 Federal Real Property Council Reporting Guidance FRPC User Guidance -for FY2006 FRPC User Guidance -for FY2006

  14. Quasi real time in vivo dosimetry for VMAT

    SciTech Connect (OSTI)

    Fidanzio, A.; Azario, L.; U.O.C di Fisica Sanitaria, Universit Cattolica del Sacro Cuore, Rome 00168; Istituto Nazionale di Fisica Nucleare , Sezione di Roma Tre, Rome 00146 ; Porcelli, A.; Greco, F.; Istituto Nazionale di Fisica Nucleare , Sezione di Roma Tre, Rome 00146 ; Cilla, S.; Grusio, M.; Balducci, M.; Valentini, V.; Piermattei, A.

    2014-06-15

    Purpose: Results about the feasibility of a method for quasi real timein vivo dosimetry (IVD) at the isocenter point for volumetric modulated arc therapy (VMAT) are here reported. The method is based on correlations between the EPID signal and the dose on the beam central axis. Moreover, the ?-analysis of EPID images was adopted to verify off-axis reproducibility of fractionated plan delivery. Methods: An algorithm to reconstructin vivo the isocenter dose, D{sub iso}, for RapidArc treatments has been developed. 20 VMAT plans, optimized with two opposite arcs, for prostate, pancreas, and head treatments have been delivered by a Varian linac both to a conic PMMA phantom with elliptical section and to patients. The ratios R between reconstructed D{sub iso} and the planned doses were determined for phantom and patient irradiations adopting an acceptance criterion of 5%. In total, 40 phantom checks and 400 patient checks were analyzed. Moreover, 3% and 3 mm criteria were adopted for portal image ?-analysis to assess patient irradiation reproducibility. Results: The average ratio R, between reconstructed and planned doses for the PMMA phantom irradiations was equal to 1.007 0.024. When the IVD method was applied to the 20 patients, the average R ratio was equal to 1.003 0.017 and 96% of the tests were within the acceptance criteria. The portal image ?-analysis supplied 88% of the tests within the pass rates ?{sub mean} ? 0.4 and P{sub ?<1} ? 98%. All the warnings were understood comparing the CT and the cone beam CT images and in one case a patient's setup error was detected and corrected for the successive fractions. Conclusions: This preliminary experience suggests that the method is able to detect dosimetric errors in quasi real time at the end of the therapy session. The authors intend to extend this procedure to other pathologies with the integration of in-room imaging verification by cone beam CT.

  15. Real Time Simulation of Power Grid Disruptions

    SciTech Connect (OSTI)

    Chinthavali, Supriya; Dimitrovski, Aleksandar D; Fernandez, Steven J; Groer, Christopher S; Nutaro, James J; Olama, Mohammed M; Omitaomu, Olufemi A; Shankar, Mallikarjun; Spafford, Kyle L; Vacaliuc, Bogdan

    2012-11-01

    DOE-OE and DOE-SC workshops (Reference 1-3) identified the key power grid problem that requires insight addressable by the next generation of exascale computing is coupling of real-time data streams (1-2 TB per hour) as the streams are ingested to dynamic models. These models would then identify predicted disruptions in time (2-4 seconds) to trigger the smart grid s self healing functions. This project attempted to establish the feasibility of this approach and defined the scientific issues, and demonstrated example solutions to important smart grid simulation problems. These objectives were accomplished by 1) using the existing frequency recorders on the national grid to establish a representative and scalable real-time data stream; 2) invoking ORNL signature identification algorithms; 3) modeling dynamically a representative region of the Eastern interconnect using an institutional cluster, measuring the scalability and computational benchmarks for a national capability; and 4) constructing a prototype simulation for the system s concept of smart grid deployment. The delivered ORNL enduring capability included: 1) data processing and simulation metrics to design a national capability justifying exascale applications; 2) Software and intellectual property built around the example solutions; 3) demonstrated dynamic models to design few second self-healing.

  16. 2007-2009 Power Rates Quarterly Updates (pbl/rates)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (PFR) Firstgov FY 2007 2009 Power Rates Quarterly Updates In BPAs 2007-2009 Wholesale Power Rate Case (WP-07), BPA agreed that it would post reports about BPAs power...

  17. October 2005 - March 2006 Power Rates (rates/previous)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    above provides a table of monthly Slice, PF, RL, and IP rates with a 30.56% non-Slice LB + FB + SN CRAC adjustment for each month of the six-month rate period. The table below...

  18. April - September 2002 Power Rates (rates/previous)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    above provides a table of monthly Slice, PF, RL, and IP rates with a 40.77% non-Slice LB CRAC adjustment for each month of the six-month rate period. The table below is simply a...

  19. October 2004 - March 2005 Power Rates (rates/previous)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    The PDF documents above provide tables of monthly Slice, PF, RL, and IP rates with the LB + FB + SN CRAC adjustments for each month of the rate period. The table below is simply...

  20. April - September 2005 Power Rates (rates/previous)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    above provides a table of monthly Slice, PF, RL, and IP rates with a 36.93% non-Slice LB + FB + SN CRAC adjustment for each month of the six-month rate period. The table below...

  1. October 2003 - March 2004 Power Rates (rates/previous)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    above provides a table of monthly Slice, PF, RL, and IP rates with a 43.66% non-Slice LB + FB + SN CRAC adjustment for each month of the rate period. The table below is simply a...

  2. October 2002 - March 2003 Power Rates (rates/previous)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    above provides a table of monthly Slice, PF, RL, and IP rates with a 43.91% non-Slice LB + FB CRAC adjustment for each month of the six-month rate period. The table below is...

  3. October 2001 - March 2002 Power Rates (rates/previous)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    above provides a table of monthly Slice, PF, RL, and IP rates with a 46% non-Slice LB CRAC adjustment for each month of the six-month rate period. The table below is simply a...

  4. April - September 2003 Power Rates (rates/previous)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    above provides a table of monthly Slice, PF, RL, and IP rates with a 49.50% non-Slice LB + FB CRAC adjustment for each month of the six-month rate period. The table below is...

  5. April - September 2004 Power Rates (rates/previous)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    above provides a table of monthly Slice, PF, RL, and IP rates with a 47.00% non-Slice LB + FB + SN CRAC adjustment for each month of the six-month rate period. The table below...

  6. WP-02 Power Rate Case (rates/ratecases)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    WP-02 Power Rate Case (Updated on May 7, 2004) In May of 2000, the BPA Administrator signed a Record of Decision (ROD) on the 2002 Final Power Rate Proposal for the October 2001...

  7. FPS-96R Rate Adjustment (rates/ratecases)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Final Firm Power Products and Services (FPS-96R) Rate Adjustment In August 1999, BPA proposed to correct errors in the Firm Power Products and Services rate schedule (FPS-96), and...

  8. National Utility Rate Database: Preprint

    SciTech Connect (OSTI)

    Ong, S.; McKeel, R.

    2012-08-01

    When modeling solar energy technologies and other distributed energy systems, using high-quality expansive electricity rates is essential. The National Renewable Energy Laboratory (NREL) developed a utility rate platform for entering, storing, updating, and accessing a large collection of utility rates from around the United States. This utility rate platform lives on the Open Energy Information (OpenEI) website, OpenEI.org, allowing the data to be programmatically accessed from a web browser, using an application programming interface (API). The semantic-based utility rate platform currently has record of 1,885 utility rates and covers over 85% of the electricity consumption in the United States.

  9. Sensor System Fo4r Buried Waste Containment Sites

    DOE Patents [OSTI]

    Smith, Ann Marie (Pocatello, ID); Gardner, Bradley M. (Idaho Falls, ID); Kostelnik, Kevin M. (Idaho Falls, ID); Partin, Judy K. (Idaho Falls, ID); Lancaster, Gregory D. (Idaho Falls, ID); Pfeifer, Mary Catherine (San Antonio, NM)

    2005-09-27

    A sensor system for a buried waste containment site having a bottom wall barrier and/or sidewall barriers, for containing hazardous waste. The sensor system includes one or more sensor devices disposed in one or more of the barriers for detecting a physical parameter either of the barrier itself or of the physical condition of the surrounding soils and buried waste, and for producing a signal representing the physical parameter detected. Also included is a signal processor for receiving signals produced by the sensor device and for developing information identifying the physical parameter detected, either for sounding an alarm, displaying a graphic representation of a physical parameter detected on a viewing screen and/or a hard copy printout. The sensor devices may be deployed in or adjacent the barriers at the same time the barriers are deployed and may be adapted to detect strain or cracking in the barriers, leakage of radiation through the barriers, the presence and leaking through the barriers of volatile organic compounds, or similar physical conditions.

  10. Sensor System Fo4r Buried Waste Containment Sites

    DOE Patents [OSTI]

    Smith, Ann Marie (Pocatello, ID); Gardner, Bradley M. (Idaho Falls, ID); Kostelnik, Kevin M. (Idaho Falls, ID); Partin, Judy K. (Idaho Falls, ID); Lancaster, Gregory D. (Idaho Falls, ID); Pfeifer, Mary Catherine (San Antonio, NM)

    2003-11-18

    A sensor system for a buried waste containment site having a bottom wall barrier and sidewall barriers, for containing hazardous waste. The sensor system includes one or more sensor devices disposed in one or more of the barriers for detecting a physical parameter either of the barrier itself or of the physical condition of the surrounding soils and buried waste, and for producing a signal representing the physical parameter detected. Also included is a signal processor for receiving signals produced by the sensor device and for developing information identifying the physical parameter detected, either for sounding an alarm, displaying a graphic representation of a physical parameter detected on a viewing screen and/or a hard copy printout. The sensor devices may be deployed in or adjacent the barriers at the same time the barriers are deployed and may be adapted to detect strain or cracking in the barriers, leakage of radiation through the barriers, the presence and leaking through the barriers of volatile organic compounds, or similar physical conditions.

  11. MEMORANDUM FO~~~ ATE DIRECTORS FROM:

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    If there are any questions, or further assistance is needed, please contact Daniel R. Lehman, Director, Office of Project Assessment (SC-28). Attachments cc: P. Dehmer, SC-2 G....

  12. Real-World Hydrogen Technology Validation: Preprint

    SciTech Connect (OSTI)

    Sprik, S.; Kurtz, J.; Wipke, K.; Ramsden, T.; Ainscough, C.; Eudy, L.; Saur, G.

    2012-03-01

    The Department of Energy, the Department of Defense's Defense Logistics Agency, and the Department of Transportation's Federal Transit Administration have funded learning demonstrations and early market deployments to provide insight into applications of hydrogen technologies on the road, in the warehouse, and as stationary power. NREL's analyses validate the technology in real-world applications, reveal the status of the technology, and facilitate the development of hydrogen and fuel cell technologies, manufacturing, and operations. This paper presents the maintenance, safety, and operation data of fuel cells in multiple applications with the reported incidents, near misses, and frequencies. NREL has analyzed records of more than 225,000 kilograms of hydrogen that have been dispensed through more than 108,000 hydrogen fills with an excellent safety record.

  13. Real time speech formant analyzer and display

    DOE Patents [OSTI]

    Holland, George E.; Struve, Walter S.; Homer, John F.

    1987-01-01

    A speech analyzer for interpretation of sound includes a sound input which converts the sound into a signal representing the sound. The signal is passed through a plurality of frequency pass filters to derive a plurality of frequency formants. These formants are converted to voltage signals by frequency-to-voltage converters and then are prepared for visual display in continuous real time. Parameters from the inputted sound are also derived and displayed. The display may then be interpreted by the user. The preferred embodiment includes a microprocessor which is interfaced with a television set for displaying of the sound formants. The microprocessor software enables the sound analyzer to present a variety of display modes for interpretive and therapeutic used by the user.

  14. Real time speech formant analyzer and display

    DOE Patents [OSTI]

    Holland, G.E.; Struve, W.S.; Homer, J.F.

    1987-02-03

    A speech analyzer for interpretation of sound includes a sound input which converts the sound into a signal representing the sound. The signal is passed through a plurality of frequency pass filters to derive a plurality of frequency formants. These formants are converted to voltage signals by frequency-to-voltage converters and then are prepared for visual display in continuous real time. Parameters from the inputted sound are also derived and displayed. The display may then be interpreted by the user. The preferred embodiment includes a microprocessor which is interfaced with a television set for displaying of the sound formants. The microprocessor software enables the sound analyzer to present a variety of display modes for interpretive and therapeutic used by the user. 19 figs.

  15. In-line real time air monitor

    DOE Patents [OSTI]

    Wise, Marcus B. (Kingston, TN); Thompson, Cyril V. (Knoxville, TN)

    1998-01-01

    An in-line gas monitor capable of accurate gas composition analysis in a continuous real time manner even under strong applied vacuum conditions operates by mixing an air sample with helium forming a sample gas in two complementary sample loops embedded in a manifold which includes two pairs of 3-way solenoid valves. The sample gas is then analyzed in an ion trap mass spectrometer on a continuous basis. Two valve drivers actuate the two pairs of 3-way valves in a reciprocating fashion, so that there is always flow through the in-line gas monitor via one or the other of the sample loops. The duty cycle for the two pairs of 3-way valves is varied by tuning the two valve drivers to a duty cycle typically between 0.2 to 0.7 seconds.

  16. In-line real time air monitor

    DOE Patents [OSTI]

    Wise, M.B.; Thompson, C.V.

    1998-07-14

    An in-line gas monitor capable of accurate gas composition analysis in a continuous real time manner even under strong applied vacuum conditions operates by mixing an air sample with helium forming a sample gas in two complementary sample loops embedded in a manifold which includes two pairs of 3-way solenoid valves. The sample gas is then analyzed in an ion trap mass spectrometer on a continuous basis. Two valve drivers actuate the two pairs of 3-way valves in a reciprocating fashion, so that there is always flow through the in-line gas monitor via one or the other of the sample loops. The duty cycle for the two pairs of 3-way valves is varied by tuning the two valve drivers to a duty cycle typically between 0.2 to 0.7 seconds. 3 figs.

  17. REAL TIME DATA FOR REMEDIATION ACTIVITIES [11505

    SciTech Connect (OSTI)

    BROCK CT

    2011-01-13

    Health physicists from the CH2M HILL Plateau Remediation Company collaborated with Berkeley Nucleonics Corporation to modify the SAM 940 isotope identifier instrument to be used for nuclear waste remediation. These modifications coupled with existing capabilities of the SAM 940 have proven to be invaluable during remediation activities, reducing disposal costs by allowing swift remediation of targeted areas that have been identified as having isotopes of concern (IOC), and eliminating multiple visits to sites by declaring an excavation site clear of IOCs before demobilizing from the site. These advantages are enabled by accumulating spectral data for specific isotopes that is nearly 100 percent free of false positives, which are filtered out in 'real time.'

  18. Use of external cavity quantum cascade laser compliance voltage in real-time trace gas sensing of multiple chemicals

    SciTech Connect (OSTI)

    Phillips, Mark C.; Taubman, Matthew S.; Kriesel, Jason M.

    2015-02-08

    We describe a prototype trace gas sensor designed for real-time detection of multiple chemicals. The sensor uses an external cavity quantum cascade laser (ECQCL) swept over its tuning range of 940-1075 cm-1 (9.30-10.7 µm) at a 10 Hz repetition rate.

  19. Kinetic Modeling of Combustion Characteristics of Real Biodiesel Fuels

    SciTech Connect (OSTI)

    Naik, C V; Westbrook, C K

    2009-04-08

    Biodiesel fuels are of much interest today either for replacing or blending with conventional fuels for automotive applications. Predicting engine effects of using biodiesel fuel requires accurate understanding of the combustion characteristics of the fuel, which can be acquired through analysis using reliable detailed reaction mechanisms. Unlike gasoline or diesel that consists of hundreds of chemical compounds, biodiesel fuels contain only a limited number of compounds. Over 90% of the biodiesel fraction is composed of 5 unique long-chain C{sub 18} and C{sub 16} saturated and unsaturated methyl esters. This makes modeling of real biodiesel fuel possible without the need for a fuel surrogate. To this end, a detailed chemical kinetic mechanism has been developed for determining the combustion characteristics of a pure biodiesel (B100) fuel, applicable from low- to high-temperature oxidation regimes. This model has been built based on reaction rate rules established in previous studies at Lawrence Livermore National Laboratory. Computed results are compared with the few fundamental experimental data that exist for biodiesel fuel and its components. In addition, computed results have been compared with experimental data for other long-chain hydrocarbons that are similar in structure to the biodiesel components.

  20. Real-time multi-mode neutron multiplicity counter

    DOE Patents [OSTI]

    Rowland, Mark S; Alvarez, Raymond A

    2013-02-26

    Embodiments are directed to a digital data acquisition method that collects data regarding nuclear fission at high rates and performs real-time preprocessing of large volumes of data into directly useable forms for use in a system that performs non-destructive assaying of nuclear material and assemblies for mass and multiplication of special nuclear material (SNM). Pulses from a multi-detector array are fed in parallel to individual inputs that are tied to individual bits in a digital word. Data is collected by loading a word at the individual bit level in parallel, to reduce the latency associated with current shift-register systems. The word is read at regular intervals, all bits simultaneously, with no manipulation. The word is passed to a number of storage locations for subsequent processing, thereby removing the front-end problem of pulse pileup. The word is used simultaneously in several internal processing schemes that assemble the data in a number of more directly useable forms. The detector includes a multi-mode counter that executes a number of different count algorithms in parallel to determine different attributes of the count data.

  1. SN-03 Rate Case Workshops (rates/meetings)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Materials Related Link: SN-03 Power Rate Case May 1 & 13, 2003 - Debt and Liquidity Strategies workshops (on BPA Corporate web site) March 27, 2003 - SN CRAC Prescheduling...

  2. Writing Effective Initial Summary Ratings Initial Summary Rating...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Writing an Effective ISR (max 8000 characters including spaces) Before writing: * Read definitions of rating levels and critical element targets carefully * Review Strategic Plan ...

  3. Department of Energy and Commercial Real Estate Executives Launch Alliance

    Energy Savers [EERE]

    to Reduce Energy Consumption of Buildings | Department of Energy Commercial Real Estate Executives Launch Alliance to Reduce Energy Consumption of Buildings Department of Energy and Commercial Real Estate Executives Launch Alliance to Reduce Energy Consumption of Buildings April 9, 2009 - 12:00am Addthis WASHINGTON, D.C. - Top executives from 19 commercial real estate companies met with U.S. Department of Energy (DOE) officials in New York City today to discuss plans to dramatically reduce

  4. Computing Eigenvalues of Real Symmetric Matrices Using Rational...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    matrices are real symmetric, most such methods rely on complex arithmetic, to solve the linear systems that arise in their implementations. An appealing technique for overcoming...

  5. DOE Announces Webinars on Real Time Energy Management, Solar...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Eastern Standard Time. This webinar will feature three Better Buildings Challenge partners that are employing real-time energy management to achieve their energy reduction goals. ...

  6. Trends in Real Estate and Energy Efficiency | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Peer Exchange Call Series: Trends in Real Estate and Energy Efficiency, call slides and discussion summary, January 22, 2015. PDF icon Call Slides and Discussion Summary More ...

  7. Mastermind Session: Connecting the Dots Between the Real Estate...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    the Dots Between the Real Estate Market and Residential Energy Efficiency Featuring Host Rich Dooley, Arlington County, VA, Call Slides and Discussion Summary, August 14, 2014. ...

  8. "Table 2. Real Average Annual Coal Transportation Costs, By Primary...

    U.S. Energy Information Administration (EIA) Indexed Site

    Real Average Annual Coal Transportation Costs, By Primary Transport Mode and Supply Region" "(2013 dollars per ton)" "Coal Supply Region",2008,2009,2010,2011,2012,2013 "Railroad"...

  9. Table 1. Real Average Transportation and Delivered Costs of Coal...

    U.S. Energy Information Administration (EIA) Indexed Site

    Real Average Transportation and Delivered Costs of Coal, By Year and Primary Transport Mode" "Year","Average Transportation Cost of Coal (Dollars per Ton)","Average Delivered Cost...

  10. Practical Considerations for Analysis By Synthesis, a Real World...

    Office of Scientific and Technical Information (OSTI)

    Practical Considerations for Analysis By Synthesis, a Real World Example using DARHT Radiography Citation Details In-Document Search Title: Practical Considerations for Analysis By...

  11. Working with Real Estate Home Inspectors, Exterminators, and...

    Broader source: Energy.gov (indexed) [DOE]

    Business Partners Peer Exchange Call: Working with Real Estate Home Inspectors, Exterminators, and other "Nontraditional" Partners, Call Slides and Discussion Summary, February...

  12. Tracking Living Cells as They Differentiate in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Tracking Living Cells as They Differentiate in Real Time Print Protein phosphorylation regulates protein function in a cell, either activating or inactivating the proteins...

  13. MHK Projects/Leancon Real Sea Test | Open Energy Information

    Open Energy Info (EERE)

    Leancon Real Sea Test < MHK Projects Jump to: navigation, search << Return to the MHK database homepage Loading map... "minzoom":false,"mappingservice":"googlemaps3","type":"ROADM...

  14. Autonomous global sky monitoring with real-time robotic follow...

    Office of Scientific and Technical Information (OSTI)

    anomalous behavior, selecting targets for detailed investigation, and making real-time anomaly detection to enable rapid recognition and a swift response to transients as...

  15. Real-space formulation of the electrostatic potential and total...

    Office of Scientific and Technical Information (OSTI)

    direct evaluation in real space. Unlike conventional reciprocal space formulations, no Fourier transforms or reciprocal lattice summations are required, and the formulation is well...

  16. Real and effective thermal equilibrium in artificial square spin...

    Office of Scientific and Technical Information (OSTI)

    Title: Real and effective thermal equilibrium in artificial square spin ices Authors: Morgan, Jason P. ; Akerman, Johanna ; Stein, Aaron ; Phatak, Charudatta ; Evans, R. M. L. ; ...

  17. Genetically encoded sensors enable real-time observation of metabolite...

    Office of Scientific and Technical Information (OSTI)

    8, 2016 Title: Genetically encoded sensors enable real-time observation of metabolite production Authors: Rogers, Jameson K. ; Church, George M. Publication Date: 2016-02-08 ...

  18. Wholesale Power Rate Schedules | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Rate Schedules Wholesale Power Rate Schedules Wholesale Power Rate Schedules October 1, 2012 ALA-1-N Wholesale Power Rate Schedule Area: PowerSouth Energy Cooperative System:...

  19. ARM - Measurement - Radiative heating rate

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    govMeasurementsRadiative heating rate ARM Data Discovery Browse Data Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Measurement : Radiative heating rate The heating rate due to the divergence of long and shortwave radiative flux. Categories Atmospheric State, Radiometric Instruments The above measurement is considered scientifically relevant for the following instruments. Refer to the datastream (netcdf) file headers of each instrument for a

  20. Rate of coal devolatilization in iron and steelmaking processes

    SciTech Connect (OSTI)

    Sampaio, R.S.; Rio Doce, C.V. do; Fruehan, R.J.; Ozturk, B. . Center for Iron and Steel Making Research)

    1991-01-01

    The devolatilization of coal particles under ironmaking and steelmaking conditions was studied. A new experimental technique was developed to measure the rates of devolatilization. A unique method was used to prepare coal particles based on thick coal bands rich in a given maceral group. Experiments with these single particles gave good reproducibility. The rates of devolatilization for all coal types from low to high rank coals were measured in the gaseous atmosphere and within the slag phase. Real time x-ray images were taken for high volatile, low volatile and anthracite coals devolatilizing in a molten smelting slag. The rate in terms of percentage devolatilization were relatively independent of coal type and a small function of furnace temperature at high heating rates and temperatures studied. The rates depended on particle size and heating rates. The results were consistent with internal transport controlled processes primarily heat transfer. Furthermore the rates were the same in the gas and slag phase which is consistent with heat transfer control.

  1. Contractor Rating and Feedback Systems

    Broader source: Energy.gov [DOE]

    Better Buildings Residential Workforce/ Business Partners Peer Exchange Call Series: Contractor Rating and Feedback Systems, Call Slides and Discussion Summary, April 24, 2014.

  2. Sustainable Building Rating Systems Summary

    SciTech Connect (OSTI)

    Fowler, Kimberly M.; Rauch, Emily M.

    2006-07-01

    The purpose of this document is to offer information that could be used to compare and contrast sustainable building rating systems.

  3. Real Time Corrosion Monitoring in Lead and Lead-Bismuth Systems

    SciTech Connect (OSTI)

    James F. Stubbins; Alan Bolind; Ziang Chen

    2010-02-25

    The objective of this research program is to develop a real-time, in situ corrosion monitoring technique for flowing liquid Pb and eutectic PbBi (LBE) systems in a temperature range of 400 to 650 C. These conditions are relevant to future liquid metal cooled fast reactor operating parameters. THis program was aligned with the Gen IV Reactor initiative to develp technologies to support the design and opertion of a Pb or LBE-cooled fast reactor. The ability to monitor corrosion for protection of structural components is a high priority issue for the safe and prolonged operation of advanced liquid metal fast reactor systems. In those systems, protective oxide layers are intentionally formed and maintained to limit corrosion rates during operation. This program developed a real time, in situ corrosion monitoring tecnique using impedance spectroscopy (IS) technology.

  4. Real time method and computer system for identifying radioactive materials from HPGe gamma-ray spectroscopy

    DOE Patents [OSTI]

    Rowland, Mark S. (Alamo, CA); Howard, Douglas E. (Livermore, CA); Wong, James L. (Dublin, CA); Jessup, James L. (Tracy, CA); Bianchini, Greg M. (Livermore, CA); Miller, Wayne O. (Livermore, CA)

    2007-10-23

    A real-time method and computer system for identifying radioactive materials which collects gamma count rates from a HPGe gamma-radiation detector to produce a high-resolution gamma-ray energy spectrum. A library of nuclear material definitions ("library definitions") is provided, with each uniquely associated with a nuclide or isotope material and each comprising at least one logic condition associated with a spectral parameter of a gamma-ray energy spectrum. The method determines whether the spectral parameters of said high-resolution gamma-ray energy spectrum satisfy all the logic conditions of any one of the library definitions, and subsequently uniquely identifies the material type as that nuclide or isotope material associated with the satisfied library definition. The method is iteratively repeated to update the spectrum and identification in real time.

  5. Real time PV manufacturing diagnostic system

    SciTech Connect (OSTI)

    Kochergin, Vladimir; Crawford, Michael A.

    2015-09-01

    The main obstacle Photovoltaic (PV) industry is facing at present is the higher cost of PV energy compared to that of fossil energy. While solar cell efficiencies continue to make incremental gains these improvements are so far insufficient to drive PV costs down to match that of fossil energy. Improved in-line diagnostics however, has the potential to significantly increase the productivity and reduce cost by improving the yield of the process. On this Phase I/Phase II SBIR project MicroXact developed and demonstrated at CIGS pilot manufacturing line a high-throughput in-line PV manufacturing diagnostic system, which was verified to provide fast and accurate data on the spatial uniformity of thickness, an composition of the thin films comprising the solar cell as the solar cell is processed reel-to-reel. In Phase II project MicroXact developed a stand-alone system prototype and demonstrated the following technical characteristics: 1) ability of real time defect/composition inconsistency detection over 60cm wide web at web speeds up to 3m/minute; 2) Better than 1mm spatial resolution on 60cm wide web; 3) an average better than 20nm spectral resolution resulting in more than sufficient sensitivity to composition imperfections (copper-rich and copper-poor regions were detected). The system was verified to be high vacuum compatible. Phase II results completely validated both technical and economic feasibility of the proposed concept. MicroXact’s solution is an enabling technique for in-line PV manufacturing diagnostics to increase the productivity of PV manufacturing lines and reduce the cost of solar energy, thus reducing the US dependency on foreign oil while simultaneously reducing emission of greenhouse gasses.

  6. Evolution of titanium arc weldment macro and microstructures -- Modeling and real time mapping of phases

    SciTech Connect (OSTI)

    Yang, Z.; Elmer, J.W.; Wong, J.; Debroy, T.

    2000-04-01

    Macro and microstructural features in gas tungsten arc (GTA) welded titanium were modeled for the first time based on a combination of transport phenomena and phase transformation theory. A transient, three-dimensional, turbulent heat transfer and fluid flow model was developed to calculate the temperature and velocity fields, thermal cycles, and the shape and size of the fusion zone. The kinetics of the {alpha}{r_arrow}{beta} allotropic transformation during continuous heating and the corresponding ({alpha}+{beta})/{beta} phase boundary were calculated using a modified Johnson-Mehl-Avrami (JMA) equation and the calculated thermal cycles. The modeling results were compared with the real-time phase mapping data obtained using a unique spatially resolved X-ray diffraction technique with synchrotron radiation. The real-time evolution of grain structure within the entire weld heat-affected zone (HAZ) was modeled in three dimensions using a Monte Carlo technique. The following are the major findings. First, the rates of heat transfer and fluid flow in the titanium weld pool during gas tungsten arc welding (GTAW) are significantly enhanced by turbulence, and previous calculations of laminar fluid flow and heat transfer in arc-melted pools need to be re-examined. The fusion zone geometry, and the {alpha}/({alpha}+{beta})/{beta} phase boundaries in the HAZ could be satisfactorily predicted. Second, comparison of real-time {alpha}{r_arrow}{beta} transformation kinetics with the rates computed assuming various alternative reaction mechanisms indicates the transition was most likely controlled by the transport of Ti atoms across the {alpha}/{beta} interface. Third, comparison of the experimental data with the simulated results indicates the real-time evolution of the grain structure around the weld pool could be simulated by the Monte Carlo technique. Finally, the insight developed in this research could not have been achieved without concomitant modeling and experiments.

  7. Real Time Telemetry Data Capture and Storage

    Energy Science and Technology Software Center (OSTI)

    1997-05-14

    This program is used to capture telemetry data from remote instrumentation systems. The data can be captured at the rate of 1M bit per second. The data can come in one of several formats, NRZ, RZ, and Bi-Phase. The DECOM software takes the serial data stream and locks on to a unique code word. By tracking the code word the software can strip out the information. Thus the program can display the incoming data realmore »time while saving the data to disk.« less

  8. BPA revises oversupply rate proposal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    comments until May 22, 2013. The rate-setting process will end with the administrator making a decision based on the record developed in the case. BPA expects to issue a final...

  9. Tier 2 Vintage Rate Workshop

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    at a Tier 2 rate 3) Combination of the two On Nov 1, 2009, customers made their elections for how they will serve their Above-RHWM Load during the FY 2012-2014 purchase...

  10. Real Time Flux Control in PM Motors

    SciTech Connect (OSTI)

    Otaduy, P.J.

    2005-09-27

    Significant research at the Oak Ridge National Laboratory (ORNL) Power Electronics and Electric Machinery Research Center (PEEMRC) is being conducted to develop ways to increase (1) torque, (2) speed range, and (3) efficiency of traction electric motors for hybrid electric vehicles (HEV) within existing current and voltage bounds. Current is limited by the inverter semiconductor devices' capability and voltage is limited by the stator wire insulation's ability to withstand the maximum back-electromotive force (emf), which occurs at the upper end of the speed range. One research track has been to explore ways to control the path and magnitude of magnetic flux while the motor is operating. The phrase, real time flux control (RTFC), refers to this mode of operation in which system parameters are changed while the motor is operating to improve its performance and speed range. RTFC has potential to meet an increased torque demand by introducing additional flux through the main air gap from an external source. It can augment the speed range by diverting flux away from the main air gap to reduce back-emf at high speeds. Conventional RTFC technology is known as vector control [1]. Vector control decomposes the stator current into two components; one that produces torque and a second that opposes (weakens) the magnetic field generated by the rotor, thereby requiring more overall stator current and reducing the efficiency. Efficiency can be improved by selecting a RTFC method that reduces the back-emf without increasing the average current. This favors methods that use pulse currents or very low currents to achieve field weakening. Foremost in ORNL's effort to develop flux control is the work of J. S. Hsu. Early research [2,3] introduced direct control of air-gap flux in permanent magnet (PM) machines and demonstrated it with a flux-controlled generator. The configuration eliminates the problem of demagnetization because it diverts all the flux from the magnets instead of trying to oppose it. It is robust and could be particularly useful for PM generators and electric vehicle drives. Recent efforts have introduced a brushless machine that transfers a magneto-motive force (MMF) generated by a stationary excitation coil to the rotor [4]. Although a conventional PM machine may be field weakened using vector control, the air-gap flux density cannot be effectively enhanced. In Hsu's new machine, the magnetic field generated by the rotor's PM may be augmented by the field from the stationery excitation coil and channeled with flux guides to its desired destination to enhance the air-gap flux that produces torque. The magnetic field can also be weakened by reversing the current in the stationary excitation winding. A patent for advanced technology in this area is pending. Several additional RTFC methods have been discussed in open literature. These include methods of changing the number of poles by magnetizing and demagnetizing the magnets poles with pulses of current corresponding to direct-axis (d-axis) current of vector control [5,6], changing the number of stator coils [7], and controlling the air gap [8]. Test experience has shown that the magnet strengths may vary and weaken naturally as rotor temperature increases suggesting that careful control of the rotor temperature, which is no easy task, could yield another method of RTFC. The purpose of this report is to (1) examine the interaction of rotor and stator flux with regard to RTFC, (2) review and summarize the status of RTFC technology, and (3) compare and evaluate methods for RTFC with respect to maturity, advantages and limitations, deployment difficulty and relative complexity.

  11. Debate response: Which rate designs provide revenue stability and efficient price signals? Let the debate continue.

    SciTech Connect (OSTI)

    Boonin, David Magnus

    2009-11-15

    Let's engage in further discussion that provides solutions and details, not just criticisms and assertions. Let's engage in a meaningful dialogue about the conditions where real-time pricing or critical peak pricing with decoupling or the SFV rate design with a feebate is most effective. (author)

  12. BPA Power Rates (pbl/main)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    rates, please see the transmission rates web site. Inactive Rate Cases Integrated Business Review (IBR) Integrated Program Review (IPR) Quarterly Business Review (QBR) Content...

  13. Capturing Energy Efficiency Upgrades in the Real Estate Transaction

    Broader source: Energy.gov [DOE]

    "Capturing Energy Efficiency Upgrades in the Real Estate Transaction," by Residential Energy Efficiency Solutions, July 10, 2012. Describes the concept of a residential MPG number as a simple way of describing a home’s energy consumption.

  14. New Real-Time Quantum Efficiency Measurement System: Preprint

    SciTech Connect (OSTI)

    Young, D. L.; Egaas, B.; Pinegar, S.; Stradins, P.

    2008-05-01

    This paper describes a newly developed technique for measuring the quantum eficiiency in solar cells in real-time using a unique, electronically controlled, full-spectrum light source.

  15. GATEWAY Demonstrations: Exploring SSL Product Performance in the Real World

    SciTech Connect (OSTI)

    2013-10-01

    Fact sheet that outlines DOE's GATEWAY technology demonstration program, which evaluates high-performance SSL products for general illumination in a variety of real-world exterior and interior applications.

  16. Towards Near Real-Time Availability With Enhanced Accuracy Turbo...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Turbo" ARSCL Towards Near Real-Time Availability With Enhanced Accuracy Turbo-ARSCL Project The goal is to speed delivery of the widely-used ARSCL product while improving the ...

  17. Building America Webinar: Building America: Research for Real...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Research for Real-World Results This presentation was delivered on Dec. 17, 2014, by Eric Werling, Building America Research Coordinator. PDF icon bawebinarwerling12-17-14.pd...

  18. Looking at Transistor Gate Oxide Formation in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Looking at Transistor Gate Oxide Formation in Real Time Print The oxide gate layer is critical to every transistor, and present-day layer thicknesses are in the 10-20 range (1-2...

  19. Workplace Charging Challenge Partner: El Camino Real Charter High School

    Broader source: Energy.gov [DOE]

    El Camino Real Charter High School (ECRCHS) has installed 4 plug-in electric vehicle (PEV) chargers, with plans to expand if demand increases. The charging stations play an integral role in...

  20. Real-time automatic fiducial marker tracking in low contrast...

    Office of Scientific and Technical Information (OSTI)

    tracking in low contrast cine-MV images Citation Details In-Document Search Title: Real-time automatic fiducial marker tracking in low contrast cine-MV images Purpose: To ...

  1. Tracking Living Cells as They Differentiate in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Tracking Living Cells as They Differentiate in Real Time Tracking Living Cells as They Differentiate in Real Time Print Thursday, 27 September 2012 00:00 Protein phosphorylation regulates protein function in a cell, either activating or inactivating the proteins responsible for many cell functions ranging from cell proliferation to differentiation to metabolism to signaling, and even programmed cell death. This chemical process has been studied intensively, but until now it has been impossible

  2. High speed, real-time, camera bandwidth converter

    DOE Patents [OSTI]

    Bower, Dan E; Bloom, David A; Curry, James R

    2014-10-21

    Image data from a CMOS sensor with 10 bit resolution is reformatted in real time to allow the data to stream through communications equipment that is designed to transport data with 8 bit resolution. The incoming image data has 10 bit resolution. The communication equipment can transport image data with 8 bit resolution. Image data with 10 bit resolution is transmitted in real-time, without a frame delay, through the communication equipment by reformatting the image data.

  3. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Real-Time Chemical Imaging of Bacterial Biofilm Development Print Wednesday, 25 August 2010 00:00 Scientists have developed a robust and label-free method to probe the chemical underpinnings of developing bacterial biofilms. Almost all bacteria can form biofilms-dynamic communities of cells enclosed in self-produced matrices of polymers that stick to other bacteria or surfaces in water-containing environments. Coordinated collectively,

  4. Practical Considerations for Analysis By Synthesis, a Real World Example

    Office of Scientific and Technical Information (OSTI)

    using DARHT Radiography (Conference) | SciTech Connect Practical Considerations for Analysis By Synthesis, a Real World Example using DARHT Radiography Citation Details In-Document Search Title: Practical Considerations for Analysis By Synthesis, a Real World Example using DARHT Radiography Authors: Carroll, James L. [1] + Show Author Affiliations Los Alamos National Laboratory Publication Date: 2013-04-30 OSTI Identifier: 1078357 Report Number(s): LA-UR-13-23130 DOE Contract Number:

  5. Real-time condition assessment of RAPTOR telescope systems (Journal

    Office of Scientific and Technical Information (OSTI)

    Article) | SciTech Connect Journal Article: Real-time condition assessment of RAPTOR telescope systems Citation Details In-Document Search Title: Real-time condition assessment of RAPTOR telescope systems × You are accessing a document from the Department of Energy's (DOE) SciTech Connect. This site is a product of DOE's Office of Scientific and Technical Information (OSTI) and is provided as a public service. Visit OSTI to utilize additional information resources in energy science and

  6. Genetically encoded sensors enable real-time observation of metabolite

    Office of Scientific and Technical Information (OSTI)

    production (Journal Article) | SciTech Connect Genetically encoded sensors enable real-time observation of metabolite production Citation Details In-Document Search This content will become publicly available on August 8, 2016 Title: Genetically encoded sensors enable real-time observation of metabolite production Authors: Rogers, Jameson K. ; Church, George M. Publication Date: 2016-02-08 OSTI Identifier: 1237386 Type: Published Article Journal Name: Proceedings of the National Academy of

  7. DOE real property: A yearly statistical handbook, Fiscal year 1992

    SciTech Connect (OSTI)

    Not Available

    1992-12-31

    To assist in the tracking, reporting, and management of the real property, DOE has an automated inventory information system. This handbook was prepared as a resource for DOE officials and others who have a need to reference real property data as part of their day-to-day functions. It is intended as an internal working document, and the information therein is a compilation or analysis of data in the information system. It is divided into: land, buildings, and other structures and facilities.

  8. Distributed Intelligence Architecture for Real-Time Control, Protection and

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Instrumentation Systems | Princeton Plasma Physics Lab Distributed Intelligence Architecture for Real-Time Control, Protection and Instrumentation Systems Architecture of complex, high-speed, Real-Time Instrumentation, Acquisition, Control and Protection systems are typically centralized with a single computer. Data from sensors is acquired, signals processed and actuated upon by a single computer with various Input and Output functionality contained within. As the size of the system grows,

  9. Vector processing enhancements for real-time image analysis.

    SciTech Connect (OSTI)

    Shoaf, S.; APS Engineering Support Division

    2008-01-01

    A real-time image analysis system was developed for beam imaging diagnostics. An Apple Power Mac G5 with an Active Silicon LFG frame grabber was used to capture video images that were processed and analyzed. Software routines were created to utilize vector-processing hardware to reduce the time to process images as compared to conventional methods. These improvements allow for more advanced image processing diagnostics to be performed in real time.

  10. Real-World PHEV Fuel Economy Prediction | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    PHEV Fuel Economy Prediction Real-World PHEV Fuel Economy Prediction 2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and Peer Evaluation PDF icon vss047_gonder_2011_o.pdf More Documents & Publications Light Duty Plug-in Hybrid Vehicle Systems Analysis Defining Real World Drive Cycles to Support APRF Technology Evaluations Analysis of maximizing the Synergy between PHEVs/EVs and PV

  11. Competition Provides Students with Real-World Engineering Experience |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Competition Provides Students with Real-World Engineering Experience Competition Provides Students with Real-World Engineering Experience April 10, 2013 - 12:00am Addthis Fifteen universities across North America are participating in EcoCAR 2-EERE's latest advanced vehicle technology competition (AVTC). Managed by Argonne National Laboratory, EcoCAR 2 is a three-year engineering competition where graduate and undergraduate students work with their universities' teams to

  12. Defining Real World Drive Cycles to Support APRF Technology Evaluations |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Real World Drive Cycles to Support APRF Technology Evaluations Defining Real World Drive Cycles to Support APRF Technology Evaluations 2012 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting PDF icon vss091_rask_2012_p.pdf More Documents & Publications Data Collection for Improved Cold Temperature Thermal Modeling Data Collection for Improved Cold Temperature Thermal Modeling and Strategy Development

  13. Capturing Energy Upgrades in the Real Estate Transaction | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Capturing Energy Upgrades in the Real Estate Transaction Capturing Energy Upgrades in the Real Estate Transaction Because green building techniques and products may impact the value of a home, they also affect the appraisal process when it comes to valuing residential properties. With the Cost Approach, the use of green features may increase the energy efficiency of a home but may add to the cost of that home's reproduction or replacement. Appraisers employing the Cost Approach should

  14. Working with Real Estate Home Inspectors, Exterminators, and Other

    Broader source: Energy.gov (indexed) [DOE]

    "Nontraditional" Partners | Department of Energy / Business Partners Peer Exchange Call: Working with Real Estate Home Inspectors, Exterminators, and other "Nontraditional" Partners, Call Slides and Discussion Summary, February 28, 2013. This workforce/business partners peer exchange call discussed working with real estate home inspectors, exterminators, and other "non-traditional" partners. PDF icon Call Slides and Discussion Summary More Documents &

  15. Mr. Anthony Reale Engineering Department Lutheran Medical Center

    Office of Legacy Management (LM)

    Anthony Reale Engineering Department Lutheran Medical Center 1550 55th Street Brooklyn, NY 11220 Dear Mr. Reale: The site of the Lutheran Medical Center was formerly used by the American Machine and Foundry Company (AMF) to provide various serviceslto the 111 Department of Energy's predecessor agency, the U.S. The services included the machining and shaping of two uranium and thorium. At the request of the Department with the consent of the Lutheran Medical Center, Oak Ridge Associated

  16. Coal Transportation Rate Sensitivity Analysis

    Reports and Publications (EIA)

    2005-01-01

    On December 21, 2004, the Surface Transportation Board (STB) requested that the Energy Information Administration (EIA) analyze the impact of changes in coal transportation rates on projected levels of electric power sector energy use and emissions. Specifically, the STB requested an analysis of changes in national and regional coal consumption and emissions resulting from adjustments in railroad transportation rates for Wyoming's Powder River Basin (PRB) coal using the National Energy Modeling System (NEMS). However, because NEMS operates at a relatively aggregate regional level and does not represent the costs of transporting coal over specific rail lines, this analysis reports on the impacts of interregional changes in transportation rates from those used in the Annual Energy Outlook 2005 (AEO2005) reference case.

  17. DOE Guidance-Category Rating

    Office of Environmental Management (EM)

    2010 MEMORANDUM FOR HUMAN RESOURCES DIRECTORS FROM: SARA"iJ. Boku1, DIRECToR OF HUMAN C~TAL MANAGEMENT SUBJECT: GUIDANCE MEMORANDUM #10 CATEGORY RATING The purpose of this memorandum is to establish the Department of Energy's (DOE's) policy for the use of Category Rating. Authorities: Public Law 107-296; Title 5 USC 3319; 5 CFR, Part 337, Subpart C., Presidential Memorandum of May 11, 2010 This guidance is established in accordance with 5 USC 3319, which authorizes Federal Agencies to use

  18. Sci—Thur PM: Planning and Delivery — 06: Real-Time Interactive Treatment Planning

    SciTech Connect (OSTI)

    Matthews, Q; Mestrovic, A; Otto, K

    2014-08-15

    Purpose: To describe and evaluate a novel system for generalized Real-Time Interactive Planning (RTIP) applied to head and neck (H and N) VMAT. Methods: The clinician interactively manipulates dose distributions using DVHs, isodoses, or rate of dose fall-off, which may be subjected to user-defined constraints. Dose is calculated using a fast Achievable Dose Estimate (ADE) algorithm, which simulates the limits of what can be achieved during treatment. After each manipulation contributing fluence elements are modified and the dose distribution updates in effectively real-time. For H and N VMAT planning, structure sets for 11 patients were imported into RTIP. Each dose distribution was interactively modified to minimize OAR dose while constraining target DVHs. The resulting RTIP DVHs were transferred to the Eclipse™ VMAT optimizer, and conventional VMAT optimization was performed. Results: Dose calculation and update times for the ADE algorithm ranged from 2.4 to 22.6 milliseconds, thus facilitating effectively real-time manipulation of dose distributions. For each of the 11 H and N VMAT cases, the RTIP process took ∼2–10 minutes. All RTIP plans exhibited acceptable PTV coverage, mean dose, and max dose. 10 of 11 RTIP plans achieved substantially improved sparing of one or more OARs without compromising dose to targets or other OARs. Importantly, 10 of the 11 RTIP plans required only one or two post-RTIP optimizations. Conclusions: RTIP is a novel system for manipulating and updating achievable dose distributions in real-time. H and N VMAT plans generated using RTIP demonstrate improved OAR sparing and planning efficiency. Disclosures: One author has a commercial interest in the presented materials.

  19. Variable gas leak rate valve

    DOE Patents [OSTI]

    Eernisse, Errol P.; Peterson, Gary D.

    1976-01-01

    A variable gas leak rate valve which utilizes a poled piezoelectric element to control opening and closing of the valve. The gas flow may be around a cylindrical rod with a tubular piezoelectric member encircling the rod for seating thereagainst to block passage of gas and for reopening thereof upon application of suitable electrical fields.

  20. Fast repetition rate (FRR) flasher

    DOE Patents [OSTI]

    Kolber, Z.; Falkowski, P.

    1997-02-11

    A fast repetition rate (FRR) flasher is described suitable for high flash photolysis including kinetic chemical and biological analysis. The flasher includes a power supply, a discharge capacitor operably connected to be charged by the power supply, and a flash lamp for producing a series of flashes in response to discharge of the discharge capacitor. A triggering circuit operably connected to the flash lamp initially ionizes the flash lamp. A current switch is operably connected between the flash lamp and the discharge capacitor. The current switch has at least one insulated gate bipolar transistor for switching current that is operable to initiate a controllable discharge of the discharge capacitor through the flash lamp. Control means connected to the current switch for controlling the rate of discharge of the discharge capacitor thereby to effectively keep the flash lamp in an ionized state between successive discharges of the discharge capacitor. Advantageously, the control means is operable to discharge the discharge capacitor at a rate greater than 10,000 Hz and even up to a rate greater than about 250,000 Hz. 14 figs.

  1. Fast repetition rate (FRR) flasher

    DOE Patents [OSTI]

    Kolber, Zbigniew (Shoreham, NY); Falkowski, Paul (Stony Brook, NY)

    1997-02-11

    A fast repetition rate (FRR) flasher suitable for high flash photolysis including kinetic chemical and biological analysis. The flasher includes a power supply, a discharge capacitor operably connected to be charged by the power supply, and a flash lamp for producing a series of flashes in response to discharge of the discharge capacitor. A triggering circuit operably connected to the flash lamp initially ionizes the flash lamp. A current switch is operably connected between the flash lamp and the discharge capacitor. The current switch has at least one insulated gate bipolar transistor for switching current that is operable to initiate a controllable discharge of the discharge capacitor through the flash lamp. Control means connected to the current switch for controlling the rate of discharge of the discharge capacitor thereby to effectively keep the flash lamp in an ionized state between Successive discharges of the discharge capacitor. Advantageously, the control means is operable to discharge the discharge capacitor at a rate greater than 10,000 Hz and even up to a rate greater than about 250,000 Hz.

  2. Evaluation Ratings Definitions (Excluding Utilization of Small...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    (Excluding Utilization of Small Business) Rating Definition Note Exceptional ... Definitions (Utilization of Small Business) Rating Definition Note Exceptional ...

  3. Review of processes for the release of DOE real and non-real property for reuse and recycle

    SciTech Connect (OSTI)

    Ranek, N.L.; Kamboj, S.; Hensley, J.; Chen, S.Y.; Blunt, D.

    1997-11-01

    This report summarizes the underlying historical and regulatory framework supporting the concept of authorizing release for restricted or unrestricted reuse or recycle of real and non-real U.S. Department of Energy (DOE) properties containing residual radioactive material. Basic radiation protection principles as recommended by the International Commission on Radiological Protection are reviewed, and international initiatives to investigate radiological clearance criteria are reported. Applicable requirements of the U.S. Nuclear Regulatory Commission, the Environmental Protection Agency, DOE, and the State of Washington are discussed. Several processes that have been developed for establishing cleanup and release criteria for real and non-real DOE property containing residual radioactive material are presented. Examples of DOE real property for which radiological cleanup criteria were established to support unrestricted release are provided. Properties discussed include Formerly Utilized Sites Remedial Action Project sites, Uranium Mill Tailings Remedial Action Project sites, the Shippingport decommissioning project, the south-middle and south-east vaults in the 317 area at Argonne National Laboratory, the Heavy Water Components Test Reactor at DOE`s Savannah River Site, the Experimental Boiling Water Reactor at Argonne National Laboratory, and the Weldon Spring site. Some examples of non-real property for which DOE sites have established criteria to support unrestricted release are also furnished. 10 figs., 4 tabs.

  4. Real-Time Trace Gas Sensing of Fluorocarbons using a Swept-wavelength External Cavity Quantum Cascade Laser

    SciTech Connect (OSTI)

    Phillips, Mark C.; Taubman, Matthew S.; Bernacki, Bruce E.; Cannon, Bret D.; Stahl, Robert D.; Schiffern, John T.; Myers, Tanya L.

    2014-05-04

    We present results demonstrating real-time sensing of four different fluorocarbons at low-ppb concentrations using an external cavity quantum cascade laser (ECQCL) operating in a swept-wavelength configuration. The ECQCL was repeatedly swept over its full tuning range at a 20 Hz rate with a scan rate of 3535 cm-1/s, and a detailed characterization of the ECQCL scan stability and repeatability is presented. The sensor was deployed on a mobile automotive platform to provide spatially resolved detection of fluorocarbons in outdoor experiments. Noise-equivalent detection limits of 800-1000 parts-per-trillion (ppt) are demonstrated for 1 s integration times.

  5. Business Models and Case Examples for Working with the Real Estate...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Business Models and Case Examples for Working with the Real Estate Sector Business Models and Case Examples for Working with the Real Estate Sector Better Buildings Neighborhood ...

  6. Real-Time Particulate Mass Measurements Pre and Post Diesel Particulat...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real-Time Particulate Mass Measurements Pre and Post Diesel Particulate Filters for ... Filter Loading and Regeneration Real-Time Measurement of Diesel Trap Efficiency ...

  7. GAO-12-645, Federal Real Property, National Strategy and Better...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2-645, Federal Real Property, National Strategy and Better Data Needed to Improve Management of Excess and Underutilized Property GAO-12-645, Federal Real Property, National...

  8. Business Models and Case Examples for Working with the Real Estate...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Business Models and Case Examples for Working with the Real Estate Sector Business Models and Case Examples for Working with the Real Estate Sector Better Buildings Neighborhood...

  9. Real-Time Dynamics Monitoring System with Synchronized Phasor Measurements

    Energy Science and Technology Software Center (OSTI)

    2005-01-01

    The Real-Time Dynamics Monitoring System is designed to monitor the dynamics within the power grid and assess the system behavior during normal and disturbance conditions. The RTDMS application was built on the Grid-3P technology platform and takes real-time information collected by Synchronized Phasor Measurement Units (PMU5) or other collection devices and transmitted to a central Phasor Data Concentrator (PDC) for monitoring grid dynamics. The data is sampled 30 times per second and is time-synchronized. Thismore »data is processed to create graphical and geographical displays to provide visualization for frequency/frequency response, voltage magnitudes and angles, voltage angle differences across critical paths as well as real and reactive power-flows on a sub-second and second basis. Software allows for monitoring, tracking, historical data archiving and electric system troubleshooting for reliability management.« less

  10. Integrated real-time fracture-diagnostics instrumentation system

    SciTech Connect (OSTI)

    Engi, D

    1983-01-01

    The use of an integrated, real-time fracture-diagnostics instrumentation system for the control of the fracturing treatment during massive hydraulic fracturing is proposed. The proposed system consists of four subsystems: an internal-fracture-pressure measurement system, a fluid-flow measurement system, a borehole seismic system, and a surface-electric-potential measurement system. This use of borehole seismic and surface-electric-potential measurements, which are essentially away-from-the-wellbore measurements, in conjunction with the use of the more commonly used types of measurements, i.e., at-the-wellbore pressure and fluid-flow measurements, is a distinctive feature of the composite real-time diagnostics system. Currently, the real-time capabilities of the individual subsystems are being developed, and the problems associated with their integration into a complete, computer-linked instrumentation system are being addressed. 2 figures.

  11. Parallel architecture for real-time simulation. Master's thesis

    SciTech Connect (OSTI)

    Cockrell, C.D.

    1989-01-01

    This thesis is concerned with the development of a very fast and highly efficient parallel computer architecture for real-time simulation of continuous systems. Currently, several parallel processing systems exist that may be capable of executing a complex simulation in real-time. These systems are examined and the pros and cons of each system discussed. The thesis then introduced a custom-designed parallel architecture based upon The University of Alabama's OPERA architecture. Each component of this system is discussed and rationale presented for its selection. The problem selected, real-time simulation of the Space Shuttle Main Engine for the test and evaluation of the proposed architecture, is explored, identifying the areas where parallelism can be exploited and parallel processing applied. Results from the test and evaluation phase are presented and compared with the results of the same problem that has been processed on a uniprocessor system.

  12. Measurement of bow tie profiles in CT scanners using a real-time dosimeter

    SciTech Connect (OSTI)

    Whiting, Bruce R.; Evans, Joshua D.; Williamson, Jeffrey F.; Dohatcu, Andreea C.; Politte, David G.

    2014-10-15

    Purpose: Several areas of computed tomography (CT) research require knowledge about the intensity profile of the x-ray fan beam that is introduced by a bow tie filter. This information is considered proprietary by CT manufacturers, so noninvasive measurement methods are required. One method using real-time dosimeters has been proposed in the literature. A commercially available dosimeter was used to apply that method, and analysis techniques were developed to extract fan beam profiles from measurements. Methods: A real-time ion chamber was placed near the periphery of an empty CT gantry and the dose rate versus time waveform was recorded as the x-ray source rotated about the isocenter. In contrast to previously proposed analysis methods that assumed a pointlike detector, the finite-size ion chamber received varying amounts of coverage by the collimated x-ray beam during rotation, precluding a simple relationship between the source intensity as a function of fan beam angle and measured intensity. A two-parameter model for measurement intensity was developed that included both effective collimation width and source-to-detector distance, which then was iteratively solved to minimize the error between duplicate measurements at corresponding fan beam angles, allowing determination of the fan beam profile from measured dose-rate waveforms. Measurements were performed on five different scanner systems while varying parameters such as collimation, kVp, and bow tie filters. On one system, direct measurements of the bow tie profile were collected for comparison with the real-time dosimeter technique. Results: The data analysis method for a finite-size detector was found to produce a fan beam profile estimate with a relative error between duplicate measurement intensities of <5%. It was robust over a wide range of collimation widths (e.g., 1–40 mm), producing fan beam profiles that agreed with a relative error of 1%–5%. Comparison with a direct measurement technique on one system produced agreement with a relative error of 2%–6%. Fan beam profiles were found to differ for different filter types on a given system and between different vendors. Conclusions: A commercially available real-time dosimeter probe was found to be a convenient and accurate instrument for measuring fan beam profiles. An analysis method was developed that could handle a wide range of collimation widths by explicitly considering the finite width of the ion chamber. Relative errors in the profiles were found to be less than 5%. Measurements of five different clinical scanners demonstrate the variation in bow tie designs, indicating that generic bow tie models will not be adequate for CT system research.

  13. Toward Real Time Data Analysis for Smart Grids

    SciTech Connect (OSTI)

    Yin, Jian; Gorton, Ian; Sharma, Poorva

    2012-11-10

    This paper describes the architecture and design of a novel system for supporting large-scale real-time data analysis for future power grid systems. The widespread deployment of renewable generation, smart grid controls, energy storage, plug-in hybrids, and new conducting materials will require fundamental changes in the operational concepts and principal components of the grid. As a result, the whole system becomes highly dynamic and requires constant adjusting based on real time data. Even though millions of sensors such as phase measurement units (PMU) and smart meters are being widely deployed, a data layer that can analyze this amount of data in real time is needed. Unlike the data fabric in other cloud services, the data layer for smart grids has some unique design requirements. First, this layer must provide real time guarantees. Second, this layer must be scalable to allow a large number of applications to access the data from millions of sensors in real time. Third, reliability is critical and this layer must be able to continue to provide service in face of failures. Fourth, this layer must be secure. We address these challenges though a scalable system architecture that integrates the I/O and data processing capability in a devise set of devices. Data process operations can be placed anywhere from sensors, data storage devices, to control centers. We further employ compression to improve performance. We design a lightweight compression customized for power grid data. Our system can reduce end-to-end response time by reduce I/O overhead through compression and overlap compression operations with I/O. The initial prototype of our system was demonstrated with several use cases from PNNL’s FPGI and show that our system can provide real time guarantees to a diverse set of applications.

  14. Commercial Building Energy Asset Rating Program -- Market Research

    SciTech Connect (OSTI)

    McCabe, Molly J.; Wang, Na

    2012-04-19

    Under contract to Pacific Northwest National Laboratory, HaydenTanner, LLC conducted an in-depth analysis of the potential market value of a commercial building energy asset rating program for the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy. The market research objectives were to: (1) Evaluate market interest and need for a program and tool to offer asset rating and rapidly identify potential energy efficiency measures for the commercial building sector. (2) Identify key input variables and asset rating outputs that would facilitate increased investment in energy efficiency. (3) Assess best practices and lessons learned from existing national and international energy rating programs. (4) Identify core messaging to motivate owners, investors, financiers, and others in the real estate sector to adopt a voluntary asset rating program and, as a consequence, deploy high-performance strategies and technologies across new and existing buildings. (5) Identify leverage factors and incentives that facilitate increased investment in these buildings. To meet these objectives, work consisted of a review of the relevant literature, examination of existing and emergent asset and operational rating systems, interviews with industry stakeholders, and an evaluation of the value implication of an asset label on asset valuation. This report documents the analysis methodology and findings, conclusion, and recommendations. Its intent is to support and inform the DOE Office of Energy Efficiency and Renewable Energy on the market need and potential value impacts of an asset labeling and diagnostic tool to encourage high-performance new buildings and building efficiency retrofit projects.

  15. A heterogeneous hierarchical architecture for real-time computing

    SciTech Connect (OSTI)

    Skroch, D.A.; Fornaro, R.J.

    1988-12-01

    The need for high-speed data acquisition and control algorithms has prompted continued research in the area of multiprocessor systems and related programming techniques. The result presented here is a unique hardware and software architecture for high-speed real-time computer systems. The implementation of a prototype of this architecture has required the integration of architecture, operating systems and programming languages into a cohesive unit. This report describes a Heterogeneous Hierarchial Architecture for Real-Time (H{sup 2} ART) and system software for program loading and interprocessor communication.

  16. Towards Real Time Diagnostics of Hybrid Welding Laser/GMAW

    SciTech Connect (OSTI)

    Timothy Mcjunkin; Dennis C. Kunerth; Corrie Nichol; Evgueni Todorov; Steve Levesque; Feng Yu; Robert Danna Couch

    2013-07-01

    Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

  17. Handheld portable real-time tracking and communications device

    DOE Patents [OSTI]

    Wiseman, James M. (Albuquerque, NM); Riblett, Jr., Loren E. (Edgewood, NM); Green, Karl L. (Albuquerque, NM); Hunter, John A. (Albuquerque, NM); Cook, III, Robert N. (Rio Rancho, NM); Stevens, James R. (Arlington, VA)

    2012-05-22

    Portable handheld real-time tracking and communications devices include; a controller module, communications module including global positioning and mesh network radio module, data transfer and storage module, and a user interface module enclosed in a water-resistant enclosure. Real-time tracking and communications devices can be used by protective force, security and first responder personnel to provide situational awareness allowing for enhance coordination and effectiveness in rapid response situations. Such devices communicate to other authorized devices via mobile ad-hoc wireless networks, and do not require fixed infrastructure for their operation.

  18. Real-time condition assessment of RAPTOR telescope systems (Conference) |

    Office of Scientific and Technical Information (OSTI)

    SciTech Connect Conference: Real-time condition assessment of RAPTOR telescope systems Citation Details In-Document Search Title: Real-time condition assessment of RAPTOR telescope systems Authors: Stull, Christopher J [1] ; Taylor, Stuart G [1] ; Wren, James [1] ; Mascarenas, David L [1] ; Farrar, Charles R [1] + Show Author Affiliations Los Alamos National Laboratory Publication Date: 2011-05-12 OSTI Identifier: 1067412 Report Number(s): LA-UR-11-02858; LA-UR-11-2858 DOE Contract Number:

  19. Real-time condition assessment of RAPTOR telescope systems (Journal

    Office of Scientific and Technical Information (OSTI)

    Article) | SciTech Connect Journal Article: Real-time condition assessment of RAPTOR telescope systems Citation Details In-Document Search Title: Real-time condition assessment of RAPTOR telescope systems Authors: Stull, Christopher J [1] ; Taylor, Stuart G [1] ; Wren, James [1] ; Mascarenas, David L [1] ; Farrar, Charles R [1] + Show Author Affiliations Los Alamos National Laboratory Publication Date: 2011-09-08 OSTI Identifier: 1095860 Report Number(s): LA-UR-11-05218; LA-UR-11-5218 DOE

  20. Towards real time diagnostics of Hybrid Welding Laser/GMAW

    SciTech Connect (OSTI)

    McJunkin, T. R.; Kunerth, D. C.; Nichol, C. I. [Idaho National Laboratory, Idaho Falls, ID 83415-3570 (United States); Todorov, E.; Levesque, S. [Edison Welding Institute, Columbus, OH (United States)

    2014-02-18

    Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

  1. Integration of Real-Time Data Into Building Automation Systems

    SciTech Connect (OSTI)

    Mark J. Stunder; Perry Sebastian; Brenda A. Chube; Michael D. Koontz

    2003-04-16

    The project goal was to investigate the possibility of using predictive real-time information from the Internet as an input to building management system algorithms. The objectives were to identify the types of information most valuable to commercial and residential building owners, managers, and system designers. To comprehensively investigate and document currently available electronic real-time information suitable for use in building management systems. Verify the reliability of the information and recommend accreditation methods for data and providers. Assess methodologies to automatically retrieve and utilize the information. Characterize equipment required to implement automated integration. Demonstrate the feasibility and benefits of using the information in building management systems. Identify evolutionary control strategies.

  2. Looking at Transistor Gate Oxide Formation in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Looking at Transistor Gate Oxide Formation in Real Time Looking at Transistor Gate Oxide Formation in Real Time Print Wednesday, 25 June 2008 00:00 The oxide gate layer is critical to every transistor, and present-day layer thicknesses are in the 10-20 Å range (1-2 nm). However, little information exists on the oxidation process at this thickness. Available results are either for thicker layers grown under high-pressure conditions or for only the first couple of monolayers studied under

  3. Wholesale Power Rate Schedules | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Power Rate Schedules October 1, 2011 CBR-1-H Wholesale Power Rate Schedule Area: Big Rivers and Henderson, KY System: CU October 1, 2011 CM-1-H Wholesale Power Rate...

  4. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: electric load data Type Term Title Author Replies Last Post sort icon...

  5. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: DOE Type Term Title Author Replies Last Post sort icon Blog entry DOE...

  6. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: API Type Term Title Author Replies Last Post sort icon Blog entry API...

  7. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: EZFeed Type Term Title Author Replies Last Post sort icon Blog entry...

  8. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: Database Type Term Title Author Replies Last Post sort icon Blog entry...

  9. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: bug Type Term Title Author Replies Last Post sort icon Discussion bug...

  10. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: energy efficiency Type Term Title Author Replies Last Post sort icon...

  11. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: clean energy Type Term Title Author Replies Last Post sort icon Blog...

  12. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: datasets Type Term Title Author Replies Last Post sort icon Blog entry...

  13. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: FOA Type Term Title Author Replies Last Post sort icon Blog entry FOA...

  14. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: Illinois State University Type Term Title Author Replies Last Post sort...

  15. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: building load Type Term Title Author Replies Last Post sort icon Blog...

  16. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: building load data Type Term Title Author Replies Last Post sort icon...

  17. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: dataset Type Term Title Author Replies Last Post sort icon Blog entry...

  18. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: Energy Visions Prize Type Term Title Author Replies Last Post sort icon...

  19. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: funding Type Term Title Author Replies Last Post sort icon Blog entry...

  20. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate Home > Utility Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: EIA Type Term Title Author Replies Last Post sort icon Blog entry EIA...

  1. Cyber security analysis testbed : combining real, emulation, and simulation.

    SciTech Connect (OSTI)

    Villamarin, Charles H.; Eldridge, John M.; Van Leeuwen, Brian P.; Urias, Vincent E.

    2010-07-01

    Cyber security analysis tools are necessary to evaluate the security, reliability, and resilience of networked information systems against cyber attack. It is common practice in modern cyber security analysis to separately utilize real systems of computers, routers, switches, firewalls, computer emulations (e.g., virtual machines) and simulation models to analyze the interplay between cyber threats and safeguards. In contrast, Sandia National Laboratories has developed novel methods to combine these evaluation platforms into a hybrid testbed that combines real, emulated, and simulated components. The combination of real, emulated, and simulated components enables the analysis of security features and components of a networked information system. When performing cyber security analysis on a system of interest, it is critical to realistically represent the subject security components in high fidelity. In some experiments, the security component may be the actual hardware and software with all the surrounding components represented in simulation or with surrogate devices. Sandia National Laboratories has developed a cyber testbed that combines modeling and simulation capabilities with virtual machines and real devices to represent, in varying fidelity, secure networked information system architectures and devices. Using this capability, secure networked information system architectures can be represented in our testbed on a single, unified computing platform. This provides an 'experiment-in-a-box' capability. The result is rapidly-produced, large-scale, relatively low-cost, multi-fidelity representations of networked information systems. These representations enable analysts to quickly investigate cyber threats and test protection approaches and configurations.

  2. Real-time graphic displays in Mars. [AVLIS process

    SciTech Connect (OSTI)

    Treadway, T.

    1985-12-01

    Real-time diagnostic data of the AVLIS process is displayed in the form of a two-dimensional plot on selected monitors in the Mars Control Room. Each Mars workstation contains a HP2622 terminal for computer interface to the experiment and a Raster Technologies graphic controller driving a Conrac high resolution color monitor for graphics output.

  3. LB CRAC Workshops (rates/meetings)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Load-Based (LB) CRAC Power Rate Adjustment Workshop Materials Related Links: Power Rate Adjustments > Load-Based (LB) CRAC December 13, 2006 LB CRAC Workshop Materials (updated...

  4. utility rate | OpenEI Community

    Open Energy Info (EERE)

    utility Utility Companies utility rate Utility Rates version 1 version 2 version 3 web service Smart meter After several months of development and testing, the next...

  5. Agent-based Large-Scale Emergency Evacuation Using Real-Time Open Government Data

    SciTech Connect (OSTI)

    Lu, Wei; Liu, Cheng; Bhaduri, Budhendra L

    2014-01-01

    The open government initiatives have provided tremendous data resources for the transportation system and emergency services in urban areas. This paper proposes a traffic simulation framework using high temporal resolution demographic data and real time open government data for evacuation planning and operation. A comparison study using real-world data in Seattle, Washington is conducted to evaluate the framework accuracy and evacuation efficiency. The successful simulations of selected area prove the concept to take advantage open government data, open source data, and high resolution demographic data in emergency management domain. There are two aspects of parameters considered in this study: user equilibrium (UE) conditions of traffic assignment model (simple Non-UE vs. iterative UE) and data temporal resolution (Daytime vs. Nighttime). Evacuation arrival rate, average travel time, and computation time are adopted as Measure of Effectiveness (MOE) for evacuation performance analysis. The temporal resolution of demographic data has significant impacts on urban transportation dynamics during evacuation scenarios. Better evacuation performance estimation can be approached by integrating both Non-UE and UE scenarios. The new framework shows flexibility in implementing different evacuation strategies and accuracy in evacuation performance. The use of this framework can be explored to day-to-day traffic assignment to support daily traffic operations.

  6. U-042: Mac RealPlayer Multiple Vulnerabilities | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    42: Mac RealPlayer Multiple Vulnerabilities U-042: Mac RealPlayer Multiple Vulnerabilities November 21, 2011 - 9:15am Addthis PROBLEM: Mac RealPlayer Multiple Vulnerabilities. PLATFORM: Versions 12.0.0.1701 and prior. ABSTRACT: Multiple vulnerabilities have been reported in Mac RealPlayer, which can be exploited by malicious people to compromise a user's system. reference LINKS: Secunia Advisory: SA46963 Secunia Vulnerability Report: Mac RealPlayer 12.x Secunia Advisory: SA46954 IMPACT

  7. Combined Retrieval, Microphysical Retrievals and Heating Rates

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Feng, Zhe

    2013-02-22

    Microphysical retrievals and heating rates from the AMIE/Gan deployment using the PNNL Combined Retrieval.

  8. Combined Retrieval, Microphysical Retrievals and Heating Rates

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Feng, Zhe

    Microphysical retrievals and heating rates from the AMIE/Gan deployment using the PNNL Combined Retrieval.

  9. Wholesale Power Rate Schedules | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Rate Schedules » Wholesale Power Rate Schedules Wholesale Power Rate Schedules October 1, 2012 ALA-1-N Wholesale Power Rate Schedule Area: PowerSouth Energy Cooperative System: Georgia-Alabama-South Carolina October 1, 2012 Duke-1-E Wholesale Power Rate Schedule Area: Duke On-System System: Georgia-Alabama-South Carolina October 1, 2012 Duke-2-E Wholesale Power Rate Schedule Area: Central System: Georgia-Alabama-South Carolina October 1, 2012 Duke-3-E Wholesale Power Rate Schedule Area: None

  10. Dynamic Line Rating Oncor Electric Delivery Smart Grid Program

    SciTech Connect (OSTI)

    Johnson, Justin; Smith, Cale; Young, Mike; Donohoo, Ken; Owen, Ross; Clark, Eddit; Espejo, Raul; Aivaliotis, Sandy; Stelmak, Ron; Mohr, Ron; Barba, Cristian; Gonzalez, Guillermo; Malkin, Stuart; Dimitrova, Vessela; Ragsdale, Gary; Mitchem, Sean; Jeirath, Nakul; Loomis, Joe; Trevino, Gerardo; Syracuse, Steve; Hurst, Neil; Mereness, Matt; Johnson, Chad; Bivens, Carrie

    2013-05-04

    Electric transmission lines are the lifeline of the electric utility industry, delivering its product from source to consumer. This critical infrastructure is often constrained such that there is inadequate capacity on existing transmission lines to efficiently deliver the power to meet demand in certain areas or to transport energy from high-generation areas to high-consumption regions. When this happens, the cost of the energy rises; more costly sources of power are used to meet the demand or the system operates less reliably. These economic impacts are known as congestion, and they can amount to substantial dollars for any time frame of reference: hour, day or year. There are several solutions to the transmission constraint problem, including: construction of new generation, construction of new transmission facilities, rebuilding and reconductoring of existing transmission assets, and Dynamic Line Rating (DLR). All of these options except DLR are capital intensive, have long lead times and often experience strong public and regulatory opposition. The Smart Grid Demonstration Program (SGDP) project co-funded by the Department of Energy (DOE) and Oncor Electric Delivery Company developed and deployed the most extensive and advanced DLR installation to demonstrate that DLR technology is capable of resolving many transmission capacity constraint problems with a system that is reliable, safe and very cost competitive. The SGDP DLR deployment is the first application of DLR technology to feed transmission line real-time dynamic ratings directly into the system operation’s State Estimator and load dispatch program, which optimizes the matching of generation with load demand on a security, reliability and economic basis. The integrated Dynamic Line Rating (iDLR)1 collects transmission line parameters at remote locations on the lines, calculates the real-time line rating based on the equivalent conductor temperature, ambient temperature and influence of wind and solar radiation on the stringing section, transmits the data to the Transmission Energy Management System, validates its integrity and passes it on to Oncor and ERCOT (Electric Reliability Council of Texas) respective system operations. The iDLR system is automatic and transparent to ERCOT System Operations, i.e., it operates in parallel with all other system status telemetry collected through Supervisory Control and Data Acquisition (SCADA) employed across the company.

  11. Wide-area, real-time monitoring and visualization system

    DOE Patents [OSTI]

    Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.

    2013-03-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  12. Real-time performance monitoring and management system

    DOE Patents [OSTI]

    Budhraja, Vikram S. (Los Angeles, CA); Dyer, James D. (La Mirada, CA); Martinez Morales, Carlos A. (Upland, CA)

    2007-06-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  13. Wide-area, real-time monitoring and visualization system

    DOE Patents [OSTI]

    Budhraja, Vikram S. (Los Angeles, CA); Dyer, James D. (La Mirada, CA); Martinez Morales, Carlos A. (Upland, CA)

    2011-11-15

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  14. Real-time multiplexed digital cavity-enhanced spectroscopy

    SciTech Connect (OSTI)

    Boyson, Toby K.; Dagdigian, Paul J.; Pavey, Karl D.; Fitzgerald, Nicholas J.; Spence, Thomas G.; Moore, David S.; Harb, Charles C.

    2015-10-01

    Cavity-enhanced spectroscopy is a sensitive optical absorption technique but one where the practical applications have been limited to studying small wavelength ranges. In addition, this Letter shows that wideband operation can be achieved by combining techniques usually reserved for the communications community with that of cavity-enhanced spectroscopy, producing a multiplexed real-time cavity-enhanced spectrometer. We use multiple collinear laser sources operating asynchronously and simultaneously while being detected on a single photodetector. This is synonymous with radio frequency (RF) cellular systems in which signals are detected on a single antenna but decoded uniquely. Here, we demonstrate results with spectra of methyl salicylate and show parts-per-billion per root hertz sensitivity measured in real-time.

  15. Real time markerless motion tracking using linked kinematic chains

    DOE Patents [OSTI]

    Luck, Jason P.; Small, Daniel E.

    2007-08-14

    A markerless method is described for tracking the motion of subjects in a three dimensional environment using a model based on linked kinematic chains. The invention is suitable for tracking robotic, animal or human subjects in real-time using a single computer with inexpensive video equipment, and does not require the use of markers or specialized clothing. A simple model of rigid linked segments is constructed of the subject and tracked using three dimensional volumetric data collected by a multiple camera video imaging system. A physics based method is then used to compute forces to align the model with subsequent volumetric data sets in real-time. The method is able to handle occlusion of segments and accommodates joint limits, velocity constraints, and collision constraints and provides for error recovery. The method further provides for elimination of singularities in Jacobian based calculations, which has been problematic in alternative methods.

  16. Real-time multiplexed digital cavity-enhanced spectroscopy

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Boyson, Toby K.; Dagdigian, Paul J.; Pavey, Karl D.; Fitzgerald, Nicholas J.; Spence, Thomas G.; Moore, David S.; Harb, Charles C.

    2015-10-01

    Cavity-enhanced spectroscopy is a sensitive optical absorption technique but one where the practical applications have been limited to studying small wavelength ranges. In addition, this Letter shows that wideband operation can be achieved by combining techniques usually reserved for the communications community with that of cavity-enhanced spectroscopy, producing a multiplexed real-time cavity-enhanced spectrometer. We use multiple collinear laser sources operating asynchronously and simultaneously while being detected on a single photodetector. This is synonymous with radio frequency (RF) cellular systems in which signals are detected on a single antenna but decoded uniquely. Here, we demonstrate results with spectra of methyl salicylatemore » and show parts-per-billion per root hertz sensitivity measured in real-time.« less

  17. Red emission phosphor for real-time skin dosimeter for fluoroscopy and interventional radiology

    SciTech Connect (OSTI)

    Nakamura, Masaaki Chida, Koichi; Zuguchi, Masayuki

    2014-10-15

    Purpose: There are no effective real-time direct skin dosimeters for interventional radiology. Such a scintillation dosimeter would be available if there was a suitable red emission phosphor in the medical x-ray range, since the silicon photodiode is a highly efficient device for red light. However, it is unknown whether there is a suitable red emission phosphor. The purpose of this study is to find a suitable red emission phosphor that can be used in x-ray dosimeters. Methods: Five kinds of phosphors which emit red light when irradiated with electron beams or ultraviolet rays in practical devices were chosen. For the brightness measurement, phosphor was put into transparent plastic cells or coated onto plastic sheets. The phosphors were irradiated with medical range x-rays [60120 kV(peak), maximum dose rate of 160 mGy min{sup ?1}], and the emission was measured by a luminance meter. Several characteristics, such as brightness, dose rate dependence, tube voltage dependence, and brightness stability, were investigated. Results: The luminescence of Y V O{sub 4}:Eu, (Y,Gd,Eu) BO{sub 3}, and Y{sub 2}O{sub 3}:Eu significantly deteriorated by 5%10% when irradiated with continuous 2 Gy x-rays. The 0.5MgF{sub 2}?3.5MgO?GeO{sub 2}:Mn phosphor did not emit enough. Only the Y{sub 2}O{sub 2}S:Eu,Sm phosphor had hardly any brightness deterioration, and it had a linear relationship so that the x-ray dose rate could be determined from the brightness with sufficient accuracy. For the tube voltage dependence of the Y{sub 2}O{sub 2}S:Eu,Sm phosphor, the brightness per unit dose rate with 120 kV(peak) x-rays was 30% higher than that with 60 kV(peak) x-rays. Conclusions: Five kinds of phosphors were chosen as an x-ray scintillator for a real-time direct skin dosimeter. The Y V O{sub 4}:Eu, (Y,Gd,Eu)BO{sub 3}, and Y{sub 2}O{sub 3}:Eu phosphors had brightness deterioration caused by the x-rays. Only the Y{sub 2}O{sub 2}S:Eu,Sm phosphor had hardly any brightness deterioration, and it is a candidate for an x-ray scintillator for such a skin dosimeter.

  18. Tracking Living Cells as They Differentiate in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Tracking Living Cells as They Differentiate in Real Time Print Protein phosphorylation regulates protein function in a cell, either activating or inactivating the proteins responsible for many cell functions ranging from cell proliferation to differentiation to metabolism to signaling, and even programmed cell death. This chemical process has been studied intensively, but until now it has been impossible to watch phosphorylation at the molecular level without damaging cells or interfering with

  19. Tracking Living Cells as They Differentiate in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Tracking Living Cells as They Differentiate in Real Time Print Protein phosphorylation regulates protein function in a cell, either activating or inactivating the proteins responsible for many cell functions ranging from cell proliferation to differentiation to metabolism to signaling, and even programmed cell death. This chemical process has been studied intensively, but until now it has been impossible to watch phosphorylation at the molecular level without damaging cells or interfering with

  20. Tracking Living Cells as They Differentiate in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Tracking Living Cells as They Differentiate in Real Time Print Protein phosphorylation regulates protein function in a cell, either activating or inactivating the proteins responsible for many cell functions ranging from cell proliferation to differentiation to metabolism to signaling, and even programmed cell death. This chemical process has been studied intensively, but until now it has been impossible to watch phosphorylation at the molecular level without damaging cells or interfering with

  1. Tracking Living Cells as They Differentiate in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Tracking Living Cells as They Differentiate in Real Time Print Protein phosphorylation regulates protein function in a cell, either activating or inactivating the proteins responsible for many cell functions ranging from cell proliferation to differentiation to metabolism to signaling, and even programmed cell death. This chemical process has been studied intensively, but until now it has been impossible to watch phosphorylation at the molecular level without damaging cells or interfering with

  2. Tracking Living Cells as They Differentiate in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Tracking Living Cells as They Differentiate in Real Time Print Protein phosphorylation regulates protein function in a cell, either activating or inactivating the proteins responsible for many cell functions ranging from cell proliferation to differentiation to metabolism to signaling, and even programmed cell death. This chemical process has been studied intensively, but until now it has been impossible to watch phosphorylation at the molecular level without damaging cells or interfering with

  3. Development of Real-Time, Gas Quality Sensor Technology

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real-Time, Gas Quality Sensor Technology Introduction Landfll gas (LFG), composed largely of methane and carbon dioxide, is used in over 645 operational projects in 48 states. These projects convert a large source of greenhouse gases into a fuel that currently provides approximately 51 trillion Btu of electricity and supplies 108 billion cubic feet of LFG annually to direct use applications and natural gas pipelines. However, there is still a signifcant resource base for new projects, with over

  4. Real Space Mapping of Oxygen Vacancy Diffusion and Electrochemical

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Transformations by Hysteretic Current Reversal Curve Measurements - Energy Innovation Portal Hydrogen and Fuel Cell Hydrogen and Fuel Cell Energy Storage Energy Storage Find More Like This Return to Search Real Space Mapping of Oxygen Vacancy Diffusion and Electrochemical Transformations by Hysteretic Current Reversal Curve Measurements Oak Ridge National Laboratory Contact ORNL About This Technology Technology Marketing SummaryElectrochemical energy storage and conversion systems based on

  5. Real Time Diagnostics for Algae-final-sm

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-time Monitoring And Diagnostics Detecting pathogens and predators to quickly recover from pond crashes Algal Pond Crash Detection Sandia National Laboratories is developing a suite of complementary technologies to help the emerging algae industry detect and quickly recover from algal pond crashes, an obstacle to large-scale algae cultivation for biofuels. Because of the way algae is grown and produced in most algal ponds, they are prone to attack by fungi, rotifers, viruses or other

  6. Real-Time Airborne Particle Analyzer - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Find More Like This Return to Search Real-Time Airborne Particle Analyzer Oak Ridge National Laboratory Contact ORNL About This Technology Technology Marketing Summary Particle analysis is useful for determining chemical compositions in a wide range of disciplines, from ascertaining the source of a petroleum sample to duplicating a fragrance. The technique is appealing to a broad cross section of analytical sciences, but its applications are limited because, for existing equipment, sample size

  7. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Print Scientists have developed a robust and label-free method to probe the chemical underpinnings of developing bacterial biofilms. Almost all bacteria can form biofilms-dynamic communities of cells enclosed in self-produced matrices of polymers that stick to other bacteria or surfaces in water-containing environments. Coordinated collectively, these bacteria defend against antagonists, break down recalcitrant materials, and produce

  8. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Print Scientists have developed a robust and label-free method to probe the chemical underpinnings of developing bacterial biofilms. Almost all bacteria can form biofilms-dynamic communities of cells enclosed in self-produced matrices of polymers that stick to other bacteria or surfaces in water-containing environments. Coordinated collectively, these bacteria defend against antagonists, break down recalcitrant materials, and produce

  9. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Print Scientists have developed a robust and label-free method to probe the chemical underpinnings of developing bacterial biofilms. Almost all bacteria can form biofilms-dynamic communities of cells enclosed in self-produced matrices of polymers that stick to other bacteria or surfaces in water-containing environments. Coordinated collectively, these bacteria defend against antagonists, break down recalcitrant materials, and produce

  10. Optical Method for Automated Real Time Control of Elemental Composition,

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Distribution, and Film Thickness in CIGS Solar Cell Production - Energy Innovation Portal Find More Like This Return to Search Optical Method for Automated Real Time Control of Elemental Composition, Distribution, and Film Thickness in CIGS Solar Cell Production National Renewable Energy Laboratory Contact NREL About This Technology Technology Marketing Summary The solar industry has shown significant growth over the past decade. From 2002 to 2007 the market for Copper Indium Gallium

  11. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Print Scientists have developed a robust and label-free method to probe the chemical underpinnings of developing bacterial biofilms. Almost all bacteria can form biofilms-dynamic communities of cells enclosed in self-produced matrices of polymers that stick to other bacteria or surfaces in water-containing environments. Coordinated collectively, these bacteria defend against antagonists, break down recalcitrant materials, and produce

  12. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Print Scientists have developed a robust and label-free method to probe the chemical underpinnings of developing bacterial biofilms. Almost all bacteria can form biofilms-dynamic communities of cells enclosed in self-produced matrices of polymers that stick to other bacteria or surfaces in water-containing environments. Coordinated collectively, these bacteria defend against antagonists, break down recalcitrant materials, and produce

  13. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Print Scientists have developed a robust and label-free method to probe the chemical underpinnings of developing bacterial biofilms. Almost all bacteria can form biofilms-dynamic communities of cells enclosed in self-produced matrices of polymers that stick to other bacteria or surfaces in water-containing environments. Coordinated collectively, these bacteria defend against antagonists, break down recalcitrant materials, and produce

  14. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Print Scientists have developed a robust and label-free method to probe the chemical underpinnings of developing bacterial biofilms. Almost all bacteria can form biofilms-dynamic communities of cells enclosed in self-produced matrices of polymers that stick to other bacteria or surfaces in water-containing environments. Coordinated collectively, these bacteria defend against antagonists, break down recalcitrant materials, and produce

  15. Real-Time Chemical Imaging of Bacterial Biofilm Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Real-Time Chemical Imaging of Bacterial Biofilm Development Print Scientists have developed a robust and label-free method to probe the chemical underpinnings of developing bacterial biofilms. Almost all bacteria can form biofilms-dynamic communities of cells enclosed in self-produced matrices of polymers that stick to other bacteria or surfaces in water-containing environments. Coordinated collectively, these bacteria defend against antagonists, break down recalcitrant materials, and produce

  16. Comparing Climate Models to Real World Shows Differences in Precipitation

    Office of Science (SC) Website

    Intensity | U.S. DOE Office of Science (SC) Comparing Climate Models to Real World Shows Differences in Precipitation Intensity Biological and Environmental Research (BER) BER Home About Research Facilities Science Highlights Searchable Archive of BER Highlights External link Benefits of BER Funding Opportunities Biological & Environmental Research Advisory Committee (BERAC) Community Resources Contact Information Biological and Environmental Research U.S. Department of Energy

  17. Illustrious Visitors Good Hosts Real Celebrity | Jefferson Lab

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Illustrious Visitors; Good Hosts! Real Celebrity. June 15, 2015 On a regular basis, the DOE Site Office asks us to update our list of illustrious visitors; often, there is nothing to say. Other times we are inundated. The past few months has seen a fine selection of events hosted by Jefferson Lab, and Jefferson Science Associates and its parent Southeastern Universities Research Association. This past week, Joachim Mnich, a member of the DESY Directorate and Chairman of ICFA, the International

  18. REAL ESTATE & EQUIPMENT LEASING / RENTAL CALIFORNIA LAWRENCE BERKELEY LAB

    Energy Savers [EERE]

    REAL ESTATE & EQUIPMENT LEASING / RENTAL CALIFORNIA LAWRENCE BERKELEY LAB POC David Chen Telephone (510) 486-4506 Email dtchen@lbl.gov Construction, Mining, and Forestry Machinery and Equipment Rental and Leasing 532412 Office Machinery and Equipment Rental and Leasing 532420 LAWRENCE LIVERMORE LAB POC Jill Swanson Telephone (925) 423-4535 Email swanson6@llnl.gov Construction, Mining, and Forestry Machinery and Equipment Rental and Leasing 532412 Office Machinery and Equipment Rental and

  19. Electromagnetic Detection and Real-Time DMLC Adaptation to Target Rotation During Radiotherapy

    SciTech Connect (OSTI)

    Wu Junqing; Ruan, Dan; Cho, Byungchul; Sawant, Amit; Petersen, Jay; Newell, Laurence J.; Cattell, Herbert; Keall, Paul J.

    2012-03-01

    Purpose: Intrafraction rotation of more than 45 Degree-Sign and 25 Degree-Sign has been observed for lung and prostate tumors, respectively. Such rotation is not routinely adapted to during current radiotherapy, which may compromise tumor dose coverage. The aim of the study was to investigate the geometric and dosimetric performance of an electromagnetically guided real-time dynamic multileaf collimator (DMLC) tracking system to adapt to intrafractional tumor rotation. Materials/Methods: Target rotation was provided by changing the treatment couch angle. The target rotation was measured by a research Calypso system integrated with a real-time DMLC tracking system employed on a Varian linac. The geometric beam-target rotational alignment difference was measured using electronic portal images. The dosimetric accuracy was quantified using a two-dimensional ion chamber array. For each beam, the following five delivery modes were tested: 1) nonrotated target (reference); 2) fixed rotated target with tracking; 3) fixed rotated target without tracking; 4) actively rotating target with tracking; and 5) actively rotating target without tracking. Dosimetric performance of the latter four modes was measured and compared to the reference dose distribution using a 3 mm/3% {gamma}-test. Results: Geometrically, the beam-target rotational alignment difference was 0.3 Degree-Sign {+-} 0.6 Degree-Sign for fixed rotation and 0.3 Degree-Sign {+-} 1.3 Degree-Sign for active rotation. Dosimetrically, the average failure rate for the {gamma}-test for a fixed rotated target was 11% with tracking and 36% without tracking. The average failure rate for an actively rotating target was 9% with tracking and 35% without tracking. Conclusions: For the first time, real-time target rotation has been accurately detected and adapted to during radiation delivery via DMLC tracking. The beam-target rotational alignment difference was mostly within 1 Degree-Sign . Dose distributions to fixed and actively rotating targets with DMLC tracking were significantly superior to those without tracking.

  20. Imaging gene expression in real-time using aptamers

    SciTech Connect (OSTI)

    Shin, Il Chung

    2011-12-13

    Signal transduction pathways are usually activated by external stimuli and are transient. The downstream changes such as transcription of the activated genes are also transient. Real-time detection of promoter activity is useful for understanding changes in gene expression, especially during cell differentiation and in development. A simple and reliable method for viewing gene expression in real time is not yet available. Reporter proteins such as fluorescent proteins and luciferase allow for non-invasive detection of the products of gene expression in living cells. However, current reporter systems do not provide for real-time imaging of promoter activity in living cells. This is because of the long time period after transcription required for fluorescent protein synthesis and maturation. We have developed an RNA reporter system for imaging in real-time to detect changes in promoter activity as they occur. The RNA reporter uses strings of RNA aptamers that constitute IMAGEtags (Intracellular MultiAptamer GEnetic tags), which can be expressed from a promoter of choice. The tobramycin, neomycin and PDC RNA aptamers have been utilized for this system and expressed in yeast from the GAL1 promoter. The IMAGEtag RNA kinetics were quantified by RT-qPCR. In yeast precultured in raffinose containing media the GAL1 promoter responded faster than in yeast precultured in glucose containing media. IMAGEtag RNA has relatively short half-life (5.5 min) in yeast. For imaging, the yeast cells are incubated with their ligands that are labeled with fluorescent dyes. To increase signal to noise, ligands have been separately conjugated with the FRET (Frster resonance energy transfer) pairs, Cy3 and Cy5. With these constructs, the transcribed aptamers can be imaged after activation of the promoter by galactose. FRET was confirmed with three different approaches, which were sensitized emission, acceptor photobleaching and donor lifetime by FLIM (fluorescence lifetime imaging microscopy). Real-time transcription was measured by FLIM-FRET, which was detected by the decrease in donor lifetime resulting from ligand binding to IMAGEtags that were newly synthesized from the activated GAL1 promoter. The FRET signal was specific for transcribed IMAGEtags.

  1. 2014-2015 Power Rate Schedules

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    4 Power Rate Schedules and General Rate Schedule Provisions (FY 2014-2015) October 2013 United States Department of Energy Bonneville Power Administration 905 N.E. 11th Avenue...

  2. Energy Efficiency Interest Rate Reduction Program

    Broader source: Energy.gov [DOE]

    For new and existing home purchases that are rated 6 Star or 5 Star Plus, applicants are eligible for an interest rate reduction for the first $200,000 of the loan amount, with a blended interest...

  3. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Rate > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: American Clean Skies Foundation Type Term Title Author Replies Last Post sort icon Blog entry...

  4. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Utility Rate Home > Groups > Groups > Utility Rate Content Group Activity By term Q & A Feeds There are no feeds from external sites for this group. Groups Menu You must login in...

  5. Category:Utility Rates | Open Energy Information

    Open Energy Info (EERE)

    Rates Jump to: navigation, search Add a new Utility Rate This category currently contains no pages or media. Retrieved from "http:en.openei.orgwindex.php?titleCategory:Utility...

  6. Residential Solar Valuation Rates | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Residential Solar Valuation Rates Residential Solar Valuation Rates This presentation summarizes the information discussed by Rabago Energy during the Best Practices in the Design of Utility Solar Programs Webinar on Sept. 27, 2012. PDF icon utility_design_rabago_energy.pdf More Documents & Publications Austin Energy's Residential Solar Rate QER - Comment of Energy Innovation 1 QER - Comment of Energy Innovation 8

  7. Real time synchrotron X-ray observations of solidification in hypoeutectic AlSi alloys

    SciTech Connect (OSTI)

    Nogita, Kazuhiro [Nihon Superior Centre for the Manufacture of Electronic Materials, The University of Queensland, Brisbane, QLD 4072 (Australia); School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, QLD 4072 (Australia); Yasuda, Hideyuki [Department of Adaptive Machine Systems, Osaka University, Suita, Osaka, 565-0871 (Japan); Prasad, Arvind [School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, QLD 4072 (Australia); McDonald, Stuart D., E-mail: s.mcdonald1@uq.edu.au [Nihon Superior Centre for the Manufacture of Electronic Materials, The University of Queensland, Brisbane, QLD 4072 (Australia); School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, QLD 4072 (Australia); Nagira, Tomoya; Nakatsuka, Noriaki [Department of Adaptive Machine Systems, Osaka University, Suita, Osaka, 565-0871 (Japan); Uesugi, Kentaro [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo, Hyogo, 679-5198 (Japan); StJohn, David H. [School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, QLD 4072 (Australia)

    2013-11-15

    This paper demonstrates how recent advances in synchrotron technology have allowed for the real-time X-ray imaging of solidification in AlSi alloys, despite the small difference in atomic number of these elements. The experiments performed at the SPring-8 synchrotron, involved imaging the solidification of Al1wt.%Si and Al4wt.%Si alloys under a low-temperature gradient and a cooling rate of around 0.3 C/s. The nucleation and growth of the primary aluminum grains as well as the onset of eutectic solidification were clearly observed. In the alloys containing Al4wt.%Si, contrast was sufficient to characterize the nucleation rate and growth velocity of the aluminum grains. The importance of improving observation of solidification in the AlSi system by increasing the time resolution during critical events is discussed. - Highlights: A synchrotron technique was used to observe solidification of Al-Si alloys. Nucleation, coarsening, and the onset of eutectic solidification were observed. Images captured are suitable for quantitative analysis. The resolution that was obtained should be possible for most aluminum alloys.

  8. Microsoft Word - GRS Review_OMB White Paper - Real Property Right...

    Energy Savers [EERE]

    GRS ReviewOMB White Paper - Real Property Right-sizing and Carbon Reduction August 7 2009 2.docx Microsoft Word - GRS ReviewOMB White Paper - Real Property Right-sizing and...

  9. Is there a source of help for setting up real time wind turbine...

    Open Energy Info (EERE)

    Is there a source of help for setting up real time wind turbine data reporting ? Home I'd like our students to be able to see historical data as well as real time power generation...

  10. V-049: RealPlayer Buffer Overflow and Invalid Pointer Flaw Let...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    V-049: RealPlayer Buffer Overflow and Invalid Pointer Flaw Let Remote Users Execute ... The vendor has issued a fix (16.0.0.282). Addthis Related Articles V-228: RealPlayer ...

  11. V-228: RealPlayer Buffer Overflow and Memory Corruption Error...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    V-228: RealPlayer Buffer Overflow and Memory Corruption Error Let Remote Users Execute ... Lets Remote Users Execute Arbitrary Code V-049: RealPlayer Buffer Overflow and Invalid ...

  12. SU-E-J-127: Real-Time Dosimetric Assessment for Adaptive Head...

    Office of Scientific and Technical Information (OSTI)

    127: Real-Time Dosimetric Assessment for Adaptive Head-And-Neck Treatment Via A GPU-Based ... Citation Details In-Document Search Title: SU-E-J-127: Real-Time Dosimetric Assessment for ...

  13. Measuring "Real World" Heavy-Duty Diesel Emissions with a Mobile...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    "Real World" Heavy-Duty Diesel Emissions with a Mobile Lab Measuring "Real World" Heavy-Duty Diesel Emissions with a Mobile Lab 2002 DEER Conference Presentation: University of ...

  14. Analysis of Battery Wear and V2G Benefits Using Real-world Drive...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Battery Wear and V2G Benefits Using Real-world Drive Cycles and Ambient Data Analysis of Battery Wear and V2G Benefits Using Real-world Drive Cycles and Ambient Data 2011 DOE...

  15. Microsoft Word - GRS Review_OMB White Paper - Real Property Right...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    By 20YY Real property inventory right-sized to X Million Square Feet by 20YY Redirect Z to other real property priorities. GOAL STATEMENT Total Carbon Footprint of Owned and...

  16. Real-time Process Monitoring and Temperature Mapping of the 3D...

    Office of Scientific and Technical Information (OSTI)

    Real-time Process Monitoring and Temperature Mapping of the 3D Polymer Printing Process Citation Details In-Document Search Title: Real-time Process Monitoring and Temperature ...

  17. Measurement of Real-World Emissions from Heavy-Duty Diesel Vehicles...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real-World Emissions from Heavy-Duty Diesel Vehicles: The State-of-the-Art Measurement of Real-World Emissions from Heavy-Duty Diesel Vehicles: The State-of-the-Art 2003 DEER ...

  18. Hubbard model corrections in real-space x-ray spectroscopy theory...

    Office of Scientific and Technical Information (OSTI)

    Hubbard model corrections in real-space x-ray spectroscopy theory Citation Details In-Document Search Title: Hubbard model corrections in real-space x-ray spectroscopy theory...

  19. U.S. Department of Energy Launches Real World Design Challenge...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real World Design Challenge U.S. Department of Energy Launches Real World Design Challenge October 20, 2008 - 4:14pm Addthis Goal of New Competition Is to Inspire High School ...

  20. Advances in Integrating Energy Efficiency into the Real Estate Market (301)

    Energy Savers [EERE]

    | Department of Energy Advances in Integrating Energy Efficiency into the Real Estate Market (301) Advances in Integrating Energy Efficiency into the Real Estate Market (301) April 21

  1. Case Study: The ''Office of Real Soon Now'' for Visualization

    SciTech Connect (OSTI)

    Uselton, S.P.

    2002-03-27

    A variation on the ''Office of Real Soon Now'' has been designed and deployed at Lawrence Livermore National Laboratory (LLNL). The ASCI VIEWS (VIEWS) program [1], the element of the program developing tools for data management and visualization, is investigating a variety of display technologies, motivated in part by the large size, high resolution, and complexity of data sets that ASCI users frequently explore and analyze. While large, tiled displays have been well received at LLNL, availability and ease-of-use problems have motivated exploration of alternatives [2]. The ''Office of Real Soon Now'' Project [3, 4, 5] at the University of North Carolina at Chapel Hill (UNC) has built ''low fidelity'' versions of the ''Office of the Future'' [6, 7] that can be installed in users' offices now. At UNC, the Office of Real Soon Now installations use only a small number of relatively inexpensive projectors,generally two or three, that limit resolution and features. These projectors are connected to Microsoft Windows PCs or Apple computers that are used for daily activities, such as reading email, writing papers, and debugging programs. Even though the UNC faculty involved are predominantly computer graphics researchers, these display systems are used mainly for text-oriented applications [5]. Designing, developing, and deploying an office-based system at LLNL would provide opportunities to adapt the system to our specific uses and to evaluate such systems for a range of tasks beyond those typically found at UNC. The goals of the LLNL display system are to exceed previous UNC versions in resolution, to run Unix-based applications, and to support interactive visualization of simulation data better than can be done via current workstations and monitors.

  2. Real-time human collaboration monitoring and intervention

    DOE Patents [OSTI]

    Merkle, Peter B.; Johnson, Curtis M.; Jones, Wendell B.; Yonas, Gerold; Doser, Adele B.; Warner, David J.

    2010-07-13

    A method of and apparatus for monitoring and intervening in, in real time, a collaboration between a plurality of subjects comprising measuring indicia of physiological and cognitive states of each of the plurality of subjects, communicating the indicia to a monitoring computer system, with the monitoring computer system, comparing the indicia with one or more models of previous collaborative performance of one or more of the plurality of subjects, and with the monitoring computer system, employing the results of the comparison to communicate commands or suggestions to one or more of the plurality of subjects.

  3. Near real time vapor detection and enhancement using aerosol adsorption

    DOE Patents [OSTI]

    Novick, V.J.; Johnson, S.A.

    1999-08-03

    A vapor sample detection method is described where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample. 13 figs.

  4. Real-time nonlinear optimization as a generalized equation.

    SciTech Connect (OSTI)

    Zavala, V. M.; Anitescu, M. (Mathematics and Computer Science)

    2010-11-11

    We establish results for the problem of tracking a time-dependent manifold arising in real-time optimization by casting this as a parametric generalized equation. We demonstrate that if points along a solution manifold are consistently strongly regular, it is possible to track the manifold approximately by solving a single linear complementarity problem (LCP) at each time step. We derive sufficient conditions guaranteeing that the tracking error remains bounded to second order with the size of the time step even if the LCP is solved only approximately. We use these results to derive a fast, augmented Lagrangian tracking algorithm and demonstrate the developments through a numerical case study.

  5. DOE - Fossil Energy: The Cleanest Coal Technology - A Real Gas

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    5-Cleanest Coal Technology An Energy Lesson Cleaning Up Coal The Cleanest Coal Technology - a Real Gas! Don't think of coal as a solid black rock. Think of it as a mass of atoms. Most of the atoms are carbon. A few are hydrogen. And there are some others, like sulfur and nitrogen, mixed in. Chemists can take this mass of atoms, break it apart, and make new substances - like gas! - The Tampa Electric Polk Power Station - One of the most advanced - and cleanest - coal power plants in the world is

  6. Near real time vapor detection and enhancement using aerosol adsorption

    DOE Patents [OSTI]

    Novick, Vincent J. (Downers Grove, IL); Johnson, Stanley A. (Countryside, IL)

    1999-01-01

    A vapor sample detection method where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample.

  7. Looking at Transistor Gate Oxide Formation in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Looking at Transistor Gate Oxide Formation in Real Time Print The oxide gate layer is critical to every transistor, and present-day layer thicknesses are in the 10-20 Å range (1-2 nm). However, little information exists on the oxidation process at this thickness. Available results are either for thicker layers grown under high-pressure conditions or for only the first couple of monolayers studied under high-vacuum conditions. Now, for the first time, a group of researchers has obtained

  8. Looking at Transistor Gate Oxide Formation in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Looking at Transistor Gate Oxide Formation in Real Time Print The oxide gate layer is critical to every transistor, and present-day layer thicknesses are in the 10-20 Å range (1-2 nm). However, little information exists on the oxidation process at this thickness. Available results are either for thicker layers grown under high-pressure conditions or for only the first couple of monolayers studied under high-vacuum conditions. Now, for the first time, a group of researchers has obtained

  9. Looking at Transistor Gate Oxide Formation in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Looking at Transistor Gate Oxide Formation in Real Time Print The oxide gate layer is critical to every transistor, and present-day layer thicknesses are in the 10-20 Å range (1-2 nm). However, little information exists on the oxidation process at this thickness. Available results are either for thicker layers grown under high-pressure conditions or for only the first couple of monolayers studied under high-vacuum conditions. Now, for the first time, a group of researchers has obtained

  10. Looking at Transistor Gate Oxide Formation in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Looking at Transistor Gate Oxide Formation in Real Time Print The oxide gate layer is critical to every transistor, and present-day layer thicknesses are in the 10-20 Å range (1-2 nm). However, little information exists on the oxidation process at this thickness. Available results are either for thicker layers grown under high-pressure conditions or for only the first couple of monolayers studied under high-vacuum conditions. Now, for the first time, a group of researchers has obtained

  11. Looking at Transistor Gate Oxide Formation in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Looking at Transistor Gate Oxide Formation in Real Time Print The oxide gate layer is critical to every transistor, and present-day layer thicknesses are in the 10-20 Å range (1-2 nm). However, little information exists on the oxidation process at this thickness. Available results are either for thicker layers grown under high-pressure conditions or for only the first couple of monolayers studied under high-vacuum conditions. Now, for the first time, a group of researchers has obtained

  12. Looking at Transistor Gate Oxide Formation in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Looking at Transistor Gate Oxide Formation in Real Time Print The oxide gate layer is critical to every transistor, and present-day layer thicknesses are in the 10-20 Å range (1-2 nm). However, little information exists on the oxidation process at this thickness. Available results are either for thicker layers grown under high-pressure conditions or for only the first couple of monolayers studied under high-vacuum conditions. Now, for the first time, a group of researchers has obtained

  13. Looking at Transistor Gate Oxide Formation in Real Time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Looking at Transistor Gate Oxide Formation in Real Time Print The oxide gate layer is critical to every transistor, and present-day layer thicknesses are in the 10-20 Å range (1-2 nm). However, little information exists on the oxidation process at this thickness. Available results are either for thicker layers grown under high-pressure conditions or for only the first couple of monolayers studied under high-vacuum conditions. Now, for the first time, a group of researchers has obtained

  14. Continuous real-time measurement of aqueous cyanide

    DOE Patents [OSTI]

    Rosentreter, Jeffrey J.; Gering, Kevin L.

    2007-03-06

    This invention provides a method and system capable of the continuous, real-time measurement of low concentrations of aqueous free cyanide (CN) using an on-line, flow through system. The system is based on the selective reactivity of cyanide anions and the characteristically nonreactive nature of metallic gold films, wherein this selective reactivity is exploited as an indirect measurement for aqueous cyanide. In the present invention the dissolution of gold, due to the solubilization reaction with the analyte cyanide anion, is monitored using a piezoelectric microbalance contained within a flow cell.

  15. Real Time Technology Application Demonstration Project Final Report

    SciTech Connect (OSTI)

    Volpe, John; Hampson, Steve; Johnson, Robert L

    2008-09-01

    The work and results described in this final report pertain to the demonstration of real-time characterization technologies applied to potentially contaminated surface soils in and around Area of Concern (AOC) 492 at the Paducah Gaseous Diffusion Plant (PGDP). The work was conducted under the auspices of Kentucky Research Consortium for Energy and Environment (KRCEE). KRCEE was created to support the Department of Energy's (DOE) efforts to complete the expeditious and economically viable environmental restoration of the Paducah Gaseous Diffusion Plant (PGDP), the Western Kentucky Wildlife Management Area (WKWMA), and surrounding areas.

  16. FY 2014 Real Property Data Related to Operations and Maintenance Guidance |

    Energy Savers [EERE]

    Department of Energy Real Property Data Related to Operations and Maintenance Guidance FY 2014 Real Property Data Related to Operations and Maintenance Guidance PDF icon FY_2014_Data_Related_to_Operations_and_Maintenance_Memorandum.pdf More Documents & Publications FY 2013 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement Guidance for Fiscal Year 2015 Facilities Information Management System Data Validations FY 2012 Real Property Deferred, Actual, and

  17. "Table 2. Real Gross Domestic Product Growth Trends, Projected vs. Actual"

    U.S. Energy Information Administration (EIA) Indexed Site

    Real Gross Domestic Product Growth Trends, Projected vs. Actual" "Projected Real GDP Growth Trend" " (cumulative average percent growth in projected real GDP from first year shown for each AEO)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO

  18. Quantitative real-time single particle analysis of virions

    SciTech Connect (OSTI)

    Heider, Susanne; Metzner, Christoph

    2014-08-15

    Providing information about single virus particles has for a long time been mainly the domain of electron microscopy. More recently, technologies have been developed—or adapted from other fields, such as nanotechnology—to allow for the real-time quantification of physical virion particles, while supplying additional information such as particle diameter concomitantly. These technologies have progressed to the stage of commercialization increasing the speed of viral titer measurements from hours to minutes, thus providing a significant advantage for many aspects of virology research and biotechnology applications. Additional advantages lie in the broad spectrum of virus species that may be measured and the possibility to determine the ratio of infectious to total particles. A series of disadvantages remain associated with these technologies, such as a low specificity for viral particles. In this review we will discuss these technologies by comparing four systems for real-time single virus particle analysis and quantification. - Highlights: • We introduce four methods for virus particle-based quantification of viruses. • They allow for quantification of a wide range of samples in under an hour time. • The additional measurement of size and zeta potential is possible for some.

  19. REAL TIME ULTRASONIC ALUMINUM SPOT WELD MONITORING SYSTEM

    SciTech Connect (OSTI)

    Regalado, W. Perez; Chertov, A. M.; Maev, R. Gr. [Institute for Diagnostic Imaging Research, Physics Department, University of Windsor, 292 Essex Hall, 401 Sunset Ave. N9B 3P4 Windsor, Ontario (Canada)

    2010-02-22

    Aluminum alloys pose several properties that make them one of the most popular engineering materials: they have excellent corrosion resistance, and high weight-to-strength ratio. Resistance spot welding of aluminum alloys is widely used today but oxide film and aluminum thermal and electrical properties make spot welding a difficult task. Electrode degradation due to pitting, alloying and mushrooming decreases the weld quality and adjustment of parameters like current and force is required. To realize these adjustments and ensure weld quality, a tool to measure weld quality in real time is required. In this paper, a real time ultrasonic non-destructive evaluation system for aluminum spot welds is presented. The system is able to monitor nugget growth while the spot weld is being made. This is achieved by interpreting the echoes of an ultrasound transducer located in one of the welding electrodes. The transducer receives and transmits an ultrasound signal at different times during the welding cycle. Valuable information of the weld quality is embedded in this signal. The system is able to determine the weld nugget diameter by measuring the delays of the ultrasound signals received during the complete welding cycle. The article presents the system performance on aluminum alloy AA6022.

  20. Real-time individualized training vectors for experiential learning.

    SciTech Connect (OSTI)

    Willis, Matt; Tucker, Eilish Marie; Raybourn, Elaine Marie; Glickman, Matthew R.; Fabian, Nathan

    2011-01-01

    Military training utilizing serious games or virtual worlds potentially generate data that can be mined to better understand how trainees learn in experiential exercises. Few data mining approaches for deployed military training games exist. Opportunities exist to collect and analyze these data, as well as to construct a full-history learner model. Outcomes discussed in the present document include results from a quasi-experimental research study on military game-based experiential learning, the deployment of an online game for training evidence collection, and results from a proof-of-concept pilot study on the development of individualized training vectors. This Lab Directed Research & Development (LDRD) project leveraged products within projects, such as Titan (Network Grand Challenge), Real-Time Feedback and Evaluation System, (America's Army Adaptive Thinking and Leadership, DARWARS Ambush! NK), and Dynamic Bayesian Networks to investigate whether machine learning capabilities could perform real-time, in-game similarity vectors of learner performance, toward adaptation of content delivery, and quantitative measurement of experiential learning.

  1. Real time nanoscale structural evaluation of gold structures on Si (100) surface using in-situ transmission electron microscopy

    SciTech Connect (OSTI)

    Rath, A. E-mail: ashutosh.phy@gmail.com E-mail: pvsatyam22@gmail.com; Juluri, R. R.; Satyam, P. V. E-mail: ashutosh.phy@gmail.com E-mail: pvsatyam22@gmail.com

    2014-05-14

    Transport behavior of gold nanostructures on Si(100) substrate during annealing under high vacuum has been investigated using in-situ real time transmission electron microscopy (TEM). A comparative study has been done on the morphological changes due to annealing under different vacuum environments. Au thin films of thickness ?2.0?nm were deposited on native oxide covered silicon substrate by using thermal evaporation system. In-situ real time TEM measurements at 850?C showed the isotropic growth of rectangular/square shaped gold-silicon alloy structures. During the growth, it is observed that the alloying occurs in liquid phase followed by transformation into the rectangular shapes. For similar system, ex-situ annealing in low vacuum (10{sup ?2} millibars) at 850?C showed the spherical gold nanostructures with no Au-Si alloy formation. Under low vacuum annealing conditions, the rate of formation of the oxide layer dominates the oxide desorption rate, resulting in the creation of a barrier layer between Au and Si, which restricts the inter diffusion of Au in to Si. This work demonstrates the important role of interfacial oxide layer on the growth of nanoscale Au-Si alloy structures during the initial growth. The time dependent TEM images are presented to offer a direct insight into the fundamental dynamics of the sintering process at the nanoscale.

  2. T-545: RealPlayer Heap Corruption Error in 'vidplin.dll' Lets Remote Users

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Execute Arbitrary Code | Department of Energy 5: RealPlayer Heap Corruption Error in 'vidplin.dll' Lets Remote Users Execute Arbitrary Code T-545: RealPlayer Heap Corruption Error in 'vidplin.dll' Lets Remote Users Execute Arbitrary Code January 28, 2011 - 7:21am Addthis PROBLEM: RealPlayer Heap Corruption Error in 'vidplin.dll' Lets Remote Users Execute Arbitrary Code. PLATFORM: RealPlayer 14.0.1 and prior versions ABSTRACT: A vulnerability was reported in RealPlayer. A remote user can

  3. V-049: RealPlayer Buffer Overflow and Invalid Pointer Flaw Let Remote Users

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Execute Arbitrary Code | Department of Energy 9: RealPlayer Buffer Overflow and Invalid Pointer Flaw Let Remote Users Execute Arbitrary Code V-049: RealPlayer Buffer Overflow and Invalid Pointer Flaw Let Remote Users Execute Arbitrary Code December 18, 2012 - 1:30am Addthis PROBLEM: RealPlayer Buffer Overflow and Invalid Pointer Flaw Let Remote Users Execute Arbitrary Code PLATFORM: Windows RealPlayer 15.0.6.14 and prior. ABSTRACT: Two vulnerabilities were reported in RealPlayer. REFERENCE

  4. V-114: RealPlayer MP4 Processing Buffer Overflow Vulnerability | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy 14: RealPlayer MP4 Processing Buffer Overflow Vulnerability V-114: RealPlayer MP4 Processing Buffer Overflow Vulnerability March 19, 2013 - 12:01am Addthis PROBLEM: RealPlayer MP4 Processing Buffer Overflow Vulnerability PLATFORM: Versions prior to 16.0.1.18. ABSTRACT: A vulnerability has been reported in RealPlayer REFERENCE LINKS: RealNetworks, Inc Secunia Advisory SA52692 CVE-2013-1750 IMPACT ASSESSMENT: High DISCUSSION: The vulnerability is caused due to an error when

  5. Order Module--DOE O 430.1B, REAL PROPERTY ASSET MANAGEMENT | Department of

    Energy Savers [EERE]

    Energy 0.1B, REAL PROPERTY ASSET MANAGEMENT Order Module--DOE O 430.1B, REAL PROPERTY ASSET MANAGEMENT "The objective of DOE O 430.1B, Real Property Asset Management, is to establish a corporate, holistic, and performance-based approach to real property life-cycle asset management that links real property asset planning, programming, budgeting, and evaluation to program mission projections and performance outcomes. To accomplish the objective, this Order identifies requirements and

  6. Public Utilities Specialist (Rates) | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Public Utilities Specialist (Rates) Public Utilities Specialist (Rates) Submitted by admin on Fri, 2016-01-08 00:16 Job Summary Organization Name Department Of Energy Agency SubElement Western Area Power Administration Locations Phoenix, Arizona Announcement Number WAPA-16-DE-70 Job Summary (See Frequently Asked Questions for more information). Where would I be working? Western Area Power Administration, Desert Southwest Region, Power Marketing, Rates and Alternative Financing, Phoenix, AZ

  7. NREL: Photovoltaics Research - Photovoltaic Energy Ratings Methods

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Validation Photovoltaic Energy Ratings Methods Validation The Photovoltaic (PV) Engineering group at NREL validates energy ratings methods by standards committees to establish an energy rating methodology. We are evaluating techniques to account for the impact on PV performance from variations in the spectral distribution of solar radiation. Two types of methods were evaluated for correcting the short-circuit current of PV modules for variations in the solar spectrum under clear skies: (1)

  8. OpenEI Community - utility rate

    Open Energy Info (EERE)

    title"" >After several months of development and testing, the next generation web service for the utility rate database is finally here I encourage you to check out...

  9. CM-1-H Wholesale Power Rate Schedule

    Broader source: Energy.gov [DOE]

    Availability:This rate schedule shall be available to the South Mississippi Electric Power Association, Municipal Energy Agency of Mississippi, and Mississippi Delta Energy Agency (hereinafter...

  10. Method of controlling fusion reaction rates

    DOE Patents [OSTI]

    Kulsrud, R.M.; Furth, H.P.; Valeo, E.J.; Goldhaber, M.

    1983-05-09

    This invention relates to a method of controlling the reaction rates in a nuclear fusion reactor; and more particularly, to the use of polarized nuclear fuel.

  11. Photovoltaic Degradation Rates -- An Analytical Review

    SciTech Connect (OSTI)

    Jordan, D. C.; Kurtz, S. R.

    2012-06-01

    As photovoltaic penetration of the power grid increases, accurate predictions of return on investment require accurate prediction of decreased power output over time. Degradation rates must be known in order to predict power delivery. This article reviews degradation rates of flat-plate terrestrial modules and systems reported in published literature from field testing throughout the last 40 years. Nearly 2000 degradation rates, measured on individual modules or entire systems, have been assembled from the literature, showing a median value of 0.5%/year. The review consists of three parts: a brief historical outline, an analytical summary of degradation rates, and a detailed bibliography partitioned by technology.

  12. BPA issues final decision on oversupply rate

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    is consistent with our multiple statutory responsibilities, is rooted in the basic principles of cost causation and fairness that underlie BPA's rate directives, and...

  13. Introducing the Attachments Energy Ratings Council

    Broader source: Energy.gov [DOE]

    In collaboration with the U.S. Department of Energy (DOE), the Window Covering Manufacturers Association (WCMA) has launched the Attachments Energy Ratings Council (AERC).

  14. Floating Rate Agreement | Department of Energy

    Office of Environmental Management (EM)

    & Publications Fixed Rate Agreement Federal Loan Guarantees for Projects that Manufacture Commercial Technology Renewable Energy Systems and Components: August 10, 2010...

  15. BPA proposes rate increase to bolster

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    proposed a 9.6 percent average wholesale power rate increase to compensate for reduced revenue expectations from surplus power sales and to continue funding needed investments in...

  16. Camera selection for real-time in vivo radiation treatment verification systems using Cherenkov imaging

    SciTech Connect (OSTI)

    Andreozzi, Jacqueline M. Glaser, Adam K.; Zhang, Rongxiao; Jarvis, Lesley A.; Gladstone, David J.; Pogue, Brian W.

    2015-02-15

    Purpose: To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. Methods: Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. Results: Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 512, compared to an ICCD which was limited to 4.7 fps at 1024 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 1024 and lower monetary cost than the EM-ICCD. Conclusions: The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 1024.

  17. RTDB: A memory resident real-time object database

    SciTech Connect (OSTI)

    Jerzy M. Nogiec; Eugene Desavouret

    2003-06-04

    RTDB is a fast, memory-resident object database with built-in support for distribution. It constitutes an attractive alternative for architecting real-time solutions with multiple, possibly distributed, processes or agents sharing data. RTDB offers both direct and navigational access to stored objects, with local and remote random access by object identifiers, and immediate direct access via object indices. The database supports transparent access to objects stored in multiple collaborating dispersed databases and includes a built-in cache mechanism that allows for keeping local copies of remote objects, with specifiable invalidation deadlines. Additional features of RTDB include a trigger mechanism on objects that allows for issuing events or activating handlers when objects are accessed or modified and a very fast, attribute based search/query mechanism. The overall architecture and application of RTDB in a control and monitoring system is presented.

  18. Smart preamplifier for real-time turbine meter diagnostics

    SciTech Connect (OSTI)

    Breter, J.C.

    1995-12-31

    A new, dual-purpose device for turbine meters, which functions as a traditional signal preamplifier and accomplishes real-time performance diagnostics, is now available. This smart preamplifier (patent pending) utilizes high speed microprocessor technology to continuously monitor and analyze the rotation of a turbine meter rotor. Continuous monitoring allows the device to detect rotational anomalies that can lead to erroneous measurements as they occur. The smart preamplifier works on liquid or gas turbine meters that use a variable reluctance pickup coil for signal generation. This paper will discuss the technology and capabilities of the smart preamplifier. To simplify this discussion, it is assumed that the signal generated will be via a non-rimmed rotor. Thus, the term ``blade`` is used throughout. However, all discussions relevant to signal generation are also true for a rimmed rotor using either buttons or slots for signal generation.

  19. Capturing Real-Time Power System Dynamics: Opportunities and Challenges

    SciTech Connect (OSTI)

    Huang, Zhenyu; Zhou, Ning; Diao, Ruisheng; Wang, Shaobu; Elbert, Stephen T.; Meng, Da; Lu, Shuai

    2015-09-01

    The power grid evolves towards a new mix of generation and consumption that introduces new dynamic and stochastic behaviors. These emerging grid behaviors would invalidate the steady-state assumption in today’s state estimation – an essential function for real-time power grid operation. This paper examines this steady-state assumption and identifies the need for estimating dynamic states. Supporting technologies are presented as well as a proposed formulation for estimating dynamic states. Metrics for evaluating methods for solving the dynamic state estimation problem are proposed, with example results to illustrate the use of these metrics. The overall objective of this paper is to provide a basis that more research on this topic can follow.

  20. Real-time calibration of a feedback trap

    SciTech Connect (OSTI)

    Gavrilov, Momčilo; Jun, Yonggun; Bechhoefer, John

    2014-09-15

    Feedback traps use closed-loop control to trap or manipulate small particles and molecules in solution. They have been applied to the measurement of physical and chemical properties of particles and to explore fundamental questions in the non-equilibrium statistical mechanics of small systems. These applications have been hampered by drifts in the electric forces used to manipulate the particles. Although the drifts are small for measurements on the order of seconds, they dominate on time scales of minutes or slower. Here, we show that a recursive maximum likelihood (RML) algorithm can allow real-time measurement and control of electric and stochastic forces over time scales of hours. Simulations show that the RML algorithm recovers known parameters accurately. Experimental estimates of diffusion coefficients are also consistent with expected physical properties.

  1. Method and apparatus for real time weld monitoring

    DOE Patents [OSTI]

    Leong, Keng H. (Lemont, IL); Hunter, Boyd V. (Bolingbrook, IL)

    1997-01-01

    An improved method and apparatus are provided for real time weld monitoring. An infrared signature emitted by a hot weld surface during welding is detected and this signature is compared with an infrared signature emitted by the weld surface during steady state conditions. The result is correlated with weld penetration. The signal processing is simpler than for either UV or acoustic techniques. Changes in the weld process, such as changes in the transmitted laser beam power, quality or positioning of the laser beam, change the resulting weld surface features and temperature of the weld surface, thereby resulting in a change in the direction and amount of infrared emissions. This change in emissions is monitored by an IR sensitive detecting apparatus that is sensitive to the appropriate wavelength region for the hot weld surface.

  2. Real-time neural network earthquake profile predictor

    DOE Patents [OSTI]

    Leach, Richard R. (Castro Valley, CA); Dowla, Farid U. (Castro Valley, CA)

    1996-01-01

    A neural network has been developed that uses first-arrival energy to predict the characteristics of impending earthquake seismograph signals. The propagation of ground motion energy through the earth is a highly nonlinear function. This is due to different forms of ground motion as well as to changes in the elastic properties of the media throughout the propagation path. The neural network is trained using seismogram data from earthquakes. Presented with a previously unseen earthquake, the neural network produces a profile of the complete earthquake signal using data from the first seconds of the signal. This offers a significant advance in the real-time monitoring, warning, and subsequent hazard minimization of catastrophic ground motion.

  3. Real-time neural network earthquake profile predictor

    DOE Patents [OSTI]

    Leach, R.R.; Dowla, F.U.

    1996-02-06

    A neural network has been developed that uses first-arrival energy to predict the characteristics of impending earthquake seismograph signals. The propagation of ground motion energy through the earth is a highly nonlinear function. This is due to different forms of ground motion as well as to changes in the elastic properties of the media throughout the propagation path. The neural network is trained using seismogram data from earthquakes. Presented with a previously unseen earthquake, the neural network produces a profile of the complete earthquake signal using data from the first seconds of the signal. This offers a significant advance in the real-time monitoring, warning, and subsequent hazard minimization of catastrophic ground motion. 17 figs.

  4. Real-Time Bioluminescent Tracking of Cellular Population Dynamics

    SciTech Connect (OSTI)

    Close, Dan; Sayler, Gary Steven; Xu, Tingting; Ripp, Steven Anthony

    2014-01-01

    Cellular population dynamics are routinely monitored across many diverse fields for a variety of purposes. In general, these dynamics are assayed either through the direct counting of cellular aliquots followed by extrapolation to the total population size, or through the monitoring of signal intensity from any number of externally stimulated reporter proteins. While both viable methods, here we describe a novel technique that allows for the automated, non-destructive tracking of cellular population dynamics in real-time. This method, which relies on the detection of a continuous bioluminescent signal produced through expression of the bacterial luciferase gene cassette, provides a low cost, low time-intensive means for generating additional data compared to alternative methods.

  5. Real-Time SCADA Cyber Protection Using Compression Techniques

    SciTech Connect (OSTI)

    Lyle G. Roybal; Gordon H Rueff

    2013-11-01

    The Department of Energys Office of Electricity Delivery and Energy Reliability (DOE-OE) has a critical mission to secure the energy infrastructure from cyber attack. Through DOE-OEs Cybersecurity for Energy Delivery Systems (CEDS) program, the Idaho National Laboratory (INL) has developed a method to detect malicious traffic on Supervisory, Control, and Data Acquisition (SCADA) network using a data compression technique. SCADA network traffic is often repetitive with only minor differences between packets. Research performed at the INL showed that SCADA network traffic has traits desirable for using compression analysis to identify abnormal network traffic. An open source implementation of a Lempel-Ziv-Welch (LZW) lossless data compression algorithm was used to compress and analyze surrogate SCADA traffic. Infected SCADA traffic was found to have statistically significant differences in compression when compared against normal SCADA traffic at the packet level. The initial analyses and results are clearly able to identify malicious network traffic from normal traffic at the packet level with a very high confidence level across multiple ports and traffic streams. Statistical differentiation between infected and normal traffic level was possible using a modified data compression technique at the 99% probability level for all data analyzed. However, the conditions tested were rather limited in scope and need to be expanded into more realistic simulations of hacking events using techniques and approaches that are better representative of a real-world attack on a SCADA system. Nonetheless, the use of compression techniques to identify malicious traffic on SCADA networks in real time appears to have significant merit for infrastructure protection.

  6. Method of controlling fusion reaction rates

    DOE Patents [OSTI]

    Kulsrud, Russell M. (Princeton, NJ); Furth, Harold P. (Princeton, NJ); Valeo, Ernest J. (Princeton Junction, NJ); Goldhaber, Maurice (Bayport, NY)

    1988-01-01

    A method of controlling the reaction rates of the fuel atoms in a fusion reactor comprises the step of polarizing the nuclei of the fuel atoms in a particular direction relative to the plasma confining magnetic field. Fusion reaction rates can be increased or decreased, and the direction of emission of the reaction products can be controlled, depending on the choice of polarization direction.

  7. Revenue-stability-target rate making

    SciTech Connect (OSTI)

    Chernick, P.L.

    1983-02-17

    The commonly used rate-making approaches necessarily base themselves on assumptions, vital to their success, about future levels of utility aservice sales. But since sales are a function of random variables beyond the control of the utility as well as actions by the utility itself, the resulting rates fail to protect the utility's revenue stream and its realized rate of return. This article proposes an alternative approach which would decouple utility revenues from sales, thus stabilizing revenue streams with respect to sales fluctuations and rate design changes. Among the benefits would be a lower cost of capital for the utility, as well as decreased utility resistance to conservation by consumers and to efficient rate design.

  8. Real-Time Distribution Feeder Performance Monitoring, Advisory Control, and Health Management System

    SciTech Connect (OSTI)

    Stoupis, James; Mousavi, Mirrasoul

    2014-09-30

    New data collection system equipment was installed in Xcel Energy substations and data was collected from 6 substations and 20 feeders. During Phase I, ABB collected and analyzed 793 real-time events to date from 6 Xcel Energy substations and continues today. The development and integration of several applications was completed during the course of this project, including a model-based faulted segment identification algorithm, with very positive results validated with field-gathered data discussed and included in this report. For mostly underground feeders, the success rate is 90% and the overreach rate is 90%. For mostly overhead feeders, the success rate is 74% and the overreach rate is 50%. The developed method is producing very accurate results for mostly underground feeders. For mostly overhead feeders, due to the bad OMS data quality and varying fault resistance when arcing, the developed method is producing good results but with much room for improvement. One area where the algorithm can be improved is the accuracy for sub-cycle fault events. In these cases, the accuracy of the conventional signal processing methods suffers due to most of these methods being based on a one-cycle processing window. By improving the signal processing accuracy, the accuracy of the faulted segment identification algorithm will also improve significantly. ABB intends to devote research in this area in the near future to help solve this problem. Other new applications developed during the course of the project include volt/VAR monitoring, unbalanced capacitor switching detection, unbalanced feeder loading detection, and feeder overloading detection. An important aspect of the demonstration phase of the project is to show the ability to provide adequate “heads-up” time ahead of customer calls or AMI reports so that the operators are provided with the much needed time to collect information needed to address an outage. The advance notification feature of the demonstration system provides this time and helps accelerate service restoration ultimately. To demonstrate the effectiveness of this feature, a demo system using substation data alone was set up to compare the minutes saved over a period of 22 months for two feeders where the real-time notification system has been deployed. The metric used for performance assessment is the time difference between the actual outage time from the OMS versus the time the notification email was received on the operators desk. Over the period of 22 months, we have accumulated over 7600 minutes (32 hours) ahead of actual outage time compared to the OMS timestamps. The significance of this analysis is that it shows the potential to reduce the SAIDI minutes and directly impact utility performance in terms of outage duration. If deployed at scale, it would have a significant impact on system reliability. To put this number in perspective, it would be helpful to assign a dollar figure to the potential savings that could be realized. According to the host utility, the average cost for each customer-minute-out (CMO) is approximately $0.30 across the operating company. This includes both direct and indirect costs such as bad press. The outage data over the previous 4 years show that the average customer count on primary/tap level outages is about 56. Accordingly, the total minutes saved amounts to 425,600 CMOs on the average. This would in turn result in a potential cost savings figure of $127,680 for two feeders alone over the period of performance. This empirical evidence validates the strong value proposition of the project that was contemplated at the onset and its potential impact to reduce outage duration in support of DOE’s goal of 20%

  9. Attenuation of wall disturbances in an electron cyclotron resonance oxygenargon plasma using real time control

    SciTech Connect (OSTI)

    Keville, Bernard, E-mail: bernard.keville@dcu.ie; Gaman, Cezar; Turner, Miles M. [National Centre for Plasma Science and Technology (NCPST), Research and Engineering Building, Dublin City University, Glasnevin, Dublin 9, Ireland and School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9 (Ireland); Zhang, Yang; Daniels, Stephen [National Centre for Plasma Science and Technology (NCPST), Research and Engineering Building, Dublin City University, Glasnevin, Dublin 9, Ireland and School of Electronic Engineering, Dublin City University, Glasnevin, Dublin 9 (Ireland); Holohan, Anthony M. [School of Electronic Engineering, Dublin City University, Glasnevin, Dublin 9 (Ireland)

    2014-07-01

    Present practice in plasma-assisted semiconductor manufacturing specifies recipes in terms of inputs such as gas flow rates, power and pressure. However, ostensibly identical chambers running identical recipes may produce very different results. Extensive chamber matching, i.e., initial iterative, empirical tuning of the process recipe, which entails time-consuming, ex situ statistical analysis of process metrics such as etch depth, uniformity, anisotropy and selectivity, is required to ensure acceptable results. Once matched, chambers are run open loop and are thus sensitive to disturbances such as actuator drift, wall seasoning and substrate loading, which may impact negatively on process reproducibility. An alternative approach, which may obviate the need for chamber matching and reduce the sensitivity of process metrics to exogenous disturbances, would be to specify a recipe in terms of quantities such as active species densities, and to regulate these in real time by adjusting the inputs with a suitable control algorithm. In this work, real time control of an electron cyclotron resonance O{sub 2}/Ar plasma used for photoresist ashing has been implemented. The design of elementary, model-based algorithms for the control of the argon 750 and oxygen 844 line intensities measured by optical emission spectroscopy is described. Fluorination of the chamber walls by means of an SF{sub 6} plasma prior to ashing inhibits wall recombination of oxygen radicals resulting in an approximately 20% increase in ash rate in the open loop case. However, closed loop control almost completely attenuates the effect of fluorination, thus demonstrating the efficacy of the control algorithms in ensuring a reproducible ash rate in the face of a wall disturbance.

  10. Measuring Degradation Rates Without Irradiance Data

    SciTech Connect (OSTI)

    Pulver, S.; Cormode, D.; Cronin, A.; Jordan, D.; Kurtz, S.; Smith, R.

    2011-02-01

    A method to report PV system degradation rates without using irradiance data is demonstrated. First, a set of relative degradation rates are determined by comparing daily AC final yields from a group of PV systems relative to the average final yield of all the PV systems. Then, the difference between relative and absolute degradation rates is found from a statistical analysis. This approach is verified by comparing to methods that utilize irradiance data. This approach is significant because PV systems are often deployed without irradiance sensors, so the analysis method described here may enable measurements of degradation using data that were previously thought to be unsuitable for degradation studies.

  11. Considerations for How to Rate CPV

    SciTech Connect (OSTI)

    Kurtz, S.; Miller, M.; Marion, B.; Emery, K.; McConnell, R.; Surendran, S.; Kimber, A.

    2011-02-01

    The concentrator photovoltaic (CPV) industry is introducing multiple products into the marketplace, but, as yet, the; community has not embraced a unified method for assessing a nameplate rating. The choices of whether to use 850,; 900, or 1000 W/m2 for the direct-normal irradiance and whether to link the rating to ambient or cell temperature will; affect how CPV modules are rated and compared with other technologies. This paper explores the qualitative and; quantitative ramifications of these choices using data from two multi-junction CPV modules and two flat-plate; modules.

  12. Using real options to evaluate the flexibility in the deployment of SMR

    SciTech Connect (OSTI)

    Locatelli, G.; Mancini, M.

    2012-07-01

    According to recent estimations the financial gap between Large Reactors (LR) and Small Medium Reactors (SMRs) seems not as huge as the economy of scale would suggest, so the SMRs are going to be important players of the worldwide nuclear renaissance. POLIMIs INCAS model has been developed to compare the investment in SMR with respect to LR. It provides the value of IRR (Internal Rate of Return), NPV (Net Present Value), LUEC (Levelized Unitary Electricity Cost), up-front investment, etc. The aim of this research is to integrate the actual INCAS model, based on discounted cash flows, with the real option theory to measure flexibility of the investor to expand, defer or abandon a nuclear project, under future uncertainties. The work compares the investment in a large nuclear power plant with a series of smaller, modular nuclear power plants on the same site. As a consequence it compares the benefits of the large power plant, coming from the economy of scale, to the benefit of the modular project (flexibility) concluding that managerial flexibility can be measured and used by an investor to face the investment risks. (authors)

  13. Property:OpenEI/UtilityRate/DemandRateStructure/Tier2Adjustment...

    Open Energy Info (EERE)

    search This is a property of type Number. Retrieved from "http:en.openei.orgwindex.php?titleProperty:OpenEIUtilityRateDemandRateStructureTier2Adjustment&oldid539746...

  14. Property:OpenEI/UtilityRate/DemandRateStructure/Tier5Max | Open...

    Open Energy Info (EERE)

    navigation, search This is a property of type Number. Retrieved from "http:en.openei.orgwindex.php?titleProperty:OpenEIUtilityRateDemandRateStructureTier5Max&oldid539754...

  15. Property:OpenEI/UtilityRate/EnergyRateStructure/Tier1Max | Open...

    Open Energy Info (EERE)

    navigation, search This is a property of type Number. Retrieved from "http:en.openei.orgwindex.php?titleProperty:OpenEIUtilityRateEnergyRateStructureTier1Max&oldid539766...

  16. Property:OpenEI/UtilityRate/EnergyRateStructure/Tier1Sell | Open...

    Open Energy Info (EERE)

    navigation, search This is a property of type Number. Retrieved from "http:en.openei.orgwindex.php?titleProperty:OpenEIUtilityRateEnergyRateStructureTier1Sell&oldid539770...

  17. Property:OpenEI/UtilityRate/DemandRateStructure/Tier6Adjustment...

    Open Energy Info (EERE)

    search This is a property of type Number. Retrieved from "http:en.openei.orgwindex.php?titleProperty:OpenEIUtilityRateDemandRateStructureTier6Adjustment&oldid539759...

  18. Property:OpenEI/UtilityRate/DemandRateStructure/Tier4Max | Open...

    Open Energy Info (EERE)

    navigation, search This is a property of type Number. Retrieved from "http:en.openei.orgwindex.php?titleProperty:OpenEIUtilityRateDemandRateStructureTier4Max&oldid539751...

  19. Getting Rate Information from the utility_rates api | OpenEI...

    Open Energy Info (EERE)

    Getting Rate Information from the utilityrates api Home > Groups > Utility Rate Hello, I am trying to use the API to generate information similar to what you can see here: http:...

  20. Property:OpenEI/UtilityRate/EnergyRateStructure/Tier4Sell | Open...

    Open Energy Info (EERE)

    Property Edit with form History Facebook icon Twitter icon Property:OpenEIUtilityRateEnergyRateStructureTier4Sell Jump to: navigation, search This is a property of type...

  1. Property:OpenEI/UtilityRate/EnergyRateStructure/Tier3Adjustment...

    Open Energy Info (EERE)

    Property Edit with form History Facebook icon Twitter icon Property:OpenEIUtilityRateEnergyRateStructureTier3Adjustment Jump to: navigation, search This is a property of type...

  2. Property:OpenEI/UtilityRate/EnergyRateStructure/Tier5Sell | Open...

    Open Energy Info (EERE)

    Property Edit with form History Facebook icon Twitter icon Property:OpenEIUtilityRateEnergyRateStructureTier5Sell Jump to: navigation, search This is a property of type...

  3. Property:OpenEI/UtilityRate/EnergyRateStructure/Period | Open...

    Open Energy Info (EERE)

    This is a property of type Number. The allowed values for this property are: 1 2 3 4 5 6 7 8 9 Pages using the property "OpenEIUtilityRateEnergyRateStructurePeriod" Showing...

  4. PSNC Energy (Gas)- Green Building Rate Discount

    Broader source: Energy.gov [DOE]

    This discounted rate is available to commercial customers whose building meets the U.S. Green Building Council’s Leadership in Energy and Environmental Design (LEED) certification or equivalent. To...

  5. Minority Utility Rate Design Assessment Model

    Energy Science and Technology Software Center (OSTI)

    2003-01-20

    Econometric model simulates consumer demand response to various user-supplied, two-part tariff electricity rate designs and assesses their economic welfare impact on black, hispanic, poor and majority households.

  6. BPA Power Rates (pbl/main)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ASC Methodology Adjustments (2007-2009) Adjustments (2002-2006) Previous Rate Cases Financial Choices (2003-06) Power Function Review (PFR) Firstgov BPA Fuel Mix 2012 2013 2014...

  7. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    > Posts by term > Utility Rate Content Group Activity By term Q & A Feeds Term: Global Atlas Type Term Title Author Replies Last Post sort icon Blog entry Global Atlas IRENA...

  8. Utility Rates | OpenEI Community

    Open Energy Info (EERE)

    Rates I'm considering removing the "Show Preview" button, since it does not work (javascript validation issue that could be fixed), and it doesn't make sense. The reason to...

  9. Uncertainty Analysis for Photovoltaic Degradation Rates (Poster)

    SciTech Connect (OSTI)

    Jordan, D.; Kurtz, S.; Hansen, C.

    2014-04-01

    Dependable and predictable energy production is the key to the long-term success of the PV industry. PV systems show over the lifetime of their exposure a gradual decline that depends on many different factors such as module technology, module type, mounting configuration, climate etc. When degradation rates are determined from continuous data the statistical uncertainty is easily calculated from the regression coefficients. However, total uncertainty that includes measurement uncertainty and instrumentation drift is far more difficult to determine. A Monte Carlo simulation approach was chosen to investigate a comprehensive uncertainty analysis. The most important effect for degradation rates is to avoid instrumentation that changes over time in the field. For instance, a drifting irradiance sensor, which can be achieved through regular calibration, can lead to a substantially erroneous degradation rates. However, the accuracy of the irradiance sensor has negligible impact on degradation rate uncertainty emphasizing that precision (relative accuracy) is more important than absolute accuracy.

  10. Contract and Tiered Rate Methodology Overview

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    historical demand to provide incentive to lower their peak by providing a marginal price signal on an incremental component of demand. The CDQs are calculated outside of the rate...

  11. Utility Rate | OpenEI Community

    Open Energy Info (EERE)

    Utility Rate Home > Groups Content Group Activity By term Q & A Feeds Share your own status updates, and follow the updates & activities of others by creating your own account. Or,...

  12. Revenue instability induced by conservation rates

    SciTech Connect (OSTI)

    Chesnutt, T.W.; McSpadden, C.; Christianson, J.

    1996-01-01

    The shift toward conservation rate structures, although they may provide better incentives to use scarce water wisely, changes who pays what and can increase the variability of future revenue streams to the water agency. Though the definition of the correct rate structure varies by community, the managerial strategies necessary to cope with the uncertainty brought about by conservation rate structures apply universally. Revenue instability directly increases water supplier`s borrowing costs and adds indirect costs in the form of more complicated planning to provide for a reliable future water supply. This article describes an empirical study using data from two water agencies that have adopted conservation rate structures. The article proposes ways quantitative tools may be used to (1) measure and cope with added uncertainty and (2) make explicit the magnitude of trade-offs between revenue stability, equity, and the provision of incentives for efficient use of water resources.

  13. Extended range radiation dose-rate monitor

    DOE Patents [OSTI]

    Valentine, Kenneth H. (Knoxville, TN)

    1988-01-01

    An extended range dose-rate monitor is provided which utilizes the pulse pileup phenomenon that occurs in conventional counting systems to alter the dynamic response of the system to extend the dose-rate counting range. The current pulses from a solid-state detector generated by radiation events are amplified and shaped prior to applying the pulses to the input of a comparator. The comparator generates one logic pulse for each input pulse which exceeds the comparator reference threshold. These pulses are integrated and applied to a meter calibrated to indicate the measured dose-rate in response to the integrator output. A portion of the output signal from the integrator is fed back to vary the comparator reference threshold in proportion to the output count rate to extend the sensitive dynamic detection range by delaying the asymptotic approach of the integrator output toward full scale as measured by the meter.

  14. Calibration and Rating of Photovoltaics: Preprint

    SciTech Connect (OSTI)

    Emery, K.

    2012-06-01

    Rating the performance of photovoltaic (PV) modules is critical to determining the cost per watt, and efficiency is useful to assess the relative progress among PV concepts. Procedures for determining the efficiency for PV technologies from 1-sun to low concentration to high concentration are discussed. We also discuss the state of the art in primary and secondary calibration of PV reference cells used by calibration laboratories around the world. Finally, we consider challenges to rating PV technologies and areas for improvement.

  15. ARM - Lesson Plans: Rate of Coral Growth

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rate of Coral Growth Outreach Home Room News Publications Traditional Knowledge Kiosks Barrow, Alaska Tropical Western Pacific Site Tours Contacts Students Study Hall About ARM Global Warming FAQ Just for Fun Meet our Friends Cool Sites Teachers Teachers' Toolbox Lesson Plans Lesson Plans: Rate of Coral Growth Objective The objective is to understand the fact that the growth of coral depends on water depth and the effect of sea level changes on corals. Materials Each student or group of students

  16. DWPF Macrobatch 2 Melt Rate Tests

    SciTech Connect (OSTI)

    Stone, M.E.

    2001-01-03

    The Defense Waste Processing Facility (DWPF) canister production rate must be increased to meet canister production goals. Although a number of factors exist that could potentially increase melt rate, this study focused on two: (1) changes in frit composition and (2) changes to the feed preparation process to alter the redox of the melter feed. These two factors were investigated for Macrobatch 2 (sludge batch 1B) utilizing crucible studies and a specially designed ''melt rate'' furnace. Other potential factors that could increase melt rate include: mechanical mixing via stirring or the use of bubblers, changing the power skewing to redistribute the power input to the melter, and elimination of heat loss (e.g. air in leakage). The melt rate testing in FY00 demonstrated that melt rate can be improved by adding a different frit or producing a much more reducing glass by the addition of sugar as a reductant. The frit that melted the fastest in the melt rate testing was Frit 165. A paper stud y was performed using the Product Composition Control System (PCCS) to determine the impact on predicted glass viscosity, liquidus, durability, and operating window if the frit was changed from Frit 200 to Frit 165. PCCS indicated that the window was very similar for both frits. In addition, the predicted viscosity of the frit 165 glass was 46 poise versus 84 poise for the Frit 200 glass. As a result, a change from Frit 200 to Frit 165 is expected to increase the melt rate in DWPF without decreasing waste loading.

  17. Wireless technology collects real-time information from oil and gas wells

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Wireless technology collects real-time information from oil and gas wells Wireless technology collects real-time information from oil and gas wells The patented system delivers continuous electromagnetic data on the reservoir conditions, enabling economical and effective monitoring and analysis. April 3, 2012 One of several active projects, LANL and Chevron co-developed INFICOMM(tm), a wireless technology used to collect real-time temperature and pressure information from sensors in oil and gas

  18. Organizing the Extremely Large LSST Database forReal-Time Astronomical

    Office of Scientific and Technical Information (OSTI)

    Processing (Conference) | SciTech Connect Organizing the Extremely Large LSST Database forReal-Time Astronomical Processing Citation Details In-Document Search Title: Organizing the Extremely Large LSST Database forReal-Time Astronomical Processing The Large Synoptic Survey Telescope (LSST) will catalog billions of astronomical objects and trillions of sources, all of which will be stored and managed by a database management system. One of the main challenges is real-time alert generation.

  19. Real-space formulation of the electrostatic potential and total energy of

    Office of Scientific and Technical Information (OSTI)

    solids (Journal Article) | SciTech Connect Journal Article: Real-space formulation of the electrostatic potential and total energy of solids Citation Details In-Document Search Title: Real-space formulation of the electrostatic potential and total energy of solids We develop expressions for the electrostatic potential and total energy of crystalline solids which are amenable to direct evaluation in real space. Unlike conventional reciprocal space formulations, no Fourier transforms or

  20. Real-time Data Access Monitoring in Distributed, Multi-petabyte Systems

    Office of Scientific and Technical Information (OSTI)

    (Conference) | SciTech Connect Real-time Data Access Monitoring in Distributed, Multi-petabyte Systems Citation Details In-Document Search Title: Real-time Data Access Monitoring in Distributed, Multi-petabyte Systems Petascale systems are in existence today and will become common in the next few years. Such systems are inevitably very complex, highly distributed and heterogeneous. Monitoring a petascale system in real-time and understanding its status at any given moment without impacting

  1. The Department's real property assets are vital to the accomplishment of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    its mission | Department of Energy The Department&#8217;s real property assets are vital to the accomplishment of its mission The Department&#8217;s real property assets are vital to the accomplishment of its mission PDF icon The Department&#8217;s real property assets are vital to the accomplishment of its mission More Documents & Publications Three Year Rolling Timeline Three-year Rolling Timeline FY2012 Three Year Rolling Timeline

  2. Vehicle Technologies Office Merit Review 2015: Analyzing Real-World Light

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Duty Vehicle Efficiency Benefits | Department of Energy Analyzing Real-World Light Duty Vehicle Efficiency Benefits Vehicle Technologies Office Merit Review 2015: Analyzing Real-World Light Duty Vehicle Efficiency Benefits Presentation given by National Renewable Energy Laboratory at 2015 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about analyzing real-world light duty vehicle efficiency benefits. PDF icon

  3. Promoting High-Performance Homes to Portland Real Estate Pros | Department

    Energy Savers [EERE]

    of Energy Promoting High-Performance Homes to Portland Real Estate Pros Promoting High-Performance Homes to Portland Real Estate Pros Photo of a woman laughing, looking at the camera. Two Portland, Oregon-based Better Buildings Residential Network members-the City of Portland Bureau of Planning and Sustainability and Clean Energy Works (CEW)-are supporting Earth Advantage's Value It Green Home Tour. On September 9, 2014, more than 300 real estate professionals learned about the latest

  4. Microsoft PowerPoint - 7-Transfer of DOE Real Property 5-7-14-Steinau

    Office of Legacy Management (LM)

    TRANSFER OF DOE REAL PROPERTY David Steinau Senior Realty Officer U.S. Department of Energy Authorities, Options, and Processes Mound Reindustrialization Workshop Miamisburg, Ohio May 20, 2014 DOE Real Property - Overview * 4 th largest landholding federal agency * 2.2 M acres * 68% withdrawn public domain land (1.5 M ac) * 24 states * National labs * Plants and facilities * Power marketing administrations * Strategic Petroleum Reserve DOE Real Property - Overview D O E O ffi c e s Bonneville

  5. Development of Real-Time, Gas Quality Sensor Technology - Fact Sheet 2015

    Office of Environmental Management (EM)

    | Department of Energy Real-Time, Gas Quality Sensor Technology - Fact Sheet 2015 Development of Real-Time, Gas Quality Sensor Technology - Fact Sheet 2015 The Gas Technology Institute, in collaboration with several project partners, will bring together real-time, gas quality sensor technology with engine management for opportunity fuels. The project is a unique industry effort that will improve the performance, increase efficiency, raise system reliability, and provide improved project

  6. Radiation Leukemogenesis at Low Dose Rates

    SciTech Connect (OSTI)

    Weil, Michael; Ullrich, Robert

    2013-09-25

    The major goals of this program were to study the efficacy of low dose rate radiation exposures for the induction of acute myeloid leukemia (AML) and to characterize the leukemias that are caused by radiation exposures at low dose rate. An irradiator facility was designed and constructed that allows large numbers of mice to be irradiated at low dose rates for protracted periods (up to their life span). To the best of our knowledge this facility is unique in the US and it was subsequently used to study radioprotectors being developed for radiological defense (PLoS One. 7(3), e33044, 2012) and is currently being used to study the role of genetic background in susceptibility to radiation-induced lung cancer. One result of the irradiation was expected; low dose rate exposures are ineffective in inducing AML. However, another result was completely unexpected; the irradiated mice had a very high incidence of hepatocellular carcinoma (HCC), approximately 50%. It was unexpected because acute exposures are ineffective in increasing HCC incidence above background. This is a potential important finding for setting exposure limits because it supports the concept of an 'inverse dose rate effect' for some tumor types. That is, for the development of some tumor types low dose rate exposures carry greater risks than acute exposures.

  7. Realization rates of the National Energy Audit

    SciTech Connect (OSTI)

    Berry, L.G.; Gettings, M.B.

    1998-11-01

    Engineering estimates of savings resulting from installation of energy conservation measures in homes are often greater than the savings actually realized. A brief review of prior studies of realization rates prefaces this study of rates from an engineering audit tool, NEAT, (developed for the Department of Energy`s Low-Income Weatherization Assistance Program) used in a New York state utility`s low-income program. Estimates of metered and predicted savings are compared for 49 homes taken from a data base of homes that participated in the first year of the utility`s program. Average realization rates ranging from 57% to 69% result, depending on the data quality. Detailed examinations of two houses using an alternate engineering method, the DOE-2 computer program (considered an industry standard), seem to indicate that the low realization rates mainly result from factors other than inaccuracies in the audit`s internal algorithms. Causes of the low realization rates are examined, showing that the strongest single factor linked to the low rates in this study is the use of secondary heating fuels that supplement the primary heating fuel. This study, like the other similar studies, concludes that engineering estimates are valuable tools in determining ranked lists of cost-effective weatherization measures, but may not be accurate substitutes for measured results in evaluating program performance.

  8. Direct Real-Time Detection of Vapors from Explosive Compounds

    SciTech Connect (OSTI)

    Ewing, Robert G.; Clowers, Brian H.; Atkinson, David A.

    2013-10-03

    The real-time detection of vapors from low volatility explosives including PETN, tetryl, RDX and nitroglycerine along with various compositions containing these substances is demonstrated. This was accomplished with an atmospheric flow tube (AFT) using a non-radioactive ionization source and coupled to a mass spectrometer. Direct vapor detection was demonstrated in less than 5 seconds at ambient temperature without sample pre-concentration. The several seconds of residence time of analytes in the AFT provides a significant opportunity for reactant ions to interact with analyte vapors to achieve ionization. This extended reaction time, combined with the selective ionization using the nitrate reactant ions (NO3- and NO3-HNO3), enables highly sensitive explosives detection. Observed signals from diluted explosive vapors indicate detection limits below 10 ppqv using selected ion monitoring (SIM) of the explosive-nitrate adduct at m/z 349, 378, 284 and 289 for tetryl, PETN, RDX and NG respectively. Also provided is a demonstration of the vapor detection from 10 different energetic formulations, including double base propellants, plastic explosives and commercial blasting explosives using SIM for the NG, PETN and RDX product ions.

  9. Cybersecurity through Real-Time Distributed Control Systems

    SciTech Connect (OSTI)

    Kisner, Roger A; Manges, Wayne W; MacIntyre, Lawrence Paul; Nutaro, James J; Munro Jr, John K; Ewing, Paul D; Howlader, Mostofa; Kuruganti, Phani Teja; Wallace, Richard M; Olama, Mohammed M

    2010-04-01

    Critical infrastructure sites and facilities are becoming increasingly dependent on interconnected physical and cyber-based real-time distributed control systems (RTDCSs). A mounting cybersecurity threat results from the nature of these ubiquitous and sometimes unrestrained communications interconnections. Much work is under way in numerous organizations to characterize the cyber threat, determine means to minimize risk, and develop mitigation strategies to address potential consequences. While it seems natural that a simple application of cyber-protection methods derived from corporate business information technology (IT) domain would lead to an acceptable solution, the reality is that the characteristics of RTDCSs make many of those methods inadequate and unsatisfactory or even harmful. A solution lies in developing a defense-in-depth approach that ranges from protection at communications interconnect levels ultimately to the control system s functional characteristics that are designed to maintain control in the face of malicious intrusion. This paper summarizes the nature of RTDCSs from a cybersecurity perspec tive and discusses issues, vulnerabilities, candidate mitigation approaches, and metrics.

  10. Standard Model with a real singlet scalar and inflation

    SciTech Connect (OSTI)

    Enqvist, Kari; Nurmi, Sami; Tenkanen, Tommi; Tuominen, Kimmo E-mail: sami.nurmi@helsinki.fi E-mail: kimmo.i.tuominen@helsinki.fi

    2014-08-01

    We study the post-inflationary dynamics of the Standard Model Higgs and a real singlet scalar s, coupled together through a renormalizable coupling ?{sub sh}h{sup 2}s{sup 2}, in a Z{sub 2} symmetric model that may explain the observed dark matter abundance and/or the origin of baryon asymmetry. The initial values for the Higgs and s condensates are given by inflationary fluctuations, and we follow their dissipation and relaxation to the low energy vacua. We find that both the lowest order perturbative and the non-perturbative decays are blocked by thermal effects and large background fields and that the condensates decay by two-loop thermal effects. Assuming instant reheating at T=10{sup 16} GeV, the characteristic temperature for the Higgs condensate thermalization is found to be T{sub h}?10{sup 14} GeV, whereas s thermalizes typically around T{sub s}?10{sup 6} GeV. By that time, the amplitude of the singlet is driven very close to the vacuum value by the expansion of the universe, unless the portal coupling takes a value ?{sub sh}?<10{sup -7} and the singlet s never thermalizes. With these values of the coupling, it is possible to slowly produce a sizeable fraction of the observed dark matter abundance via singlet condensate fragmentation and thermal Higgs scattering. Physics also below the electroweak scale can therefore be affected by the non-vacuum initial conditions generated by inflation.

  11. Map Matching and Real World Integrated Sensor Data Warehousing (Presentation)

    SciTech Connect (OSTI)

    Burton, E.

    2014-02-01

    The inclusion of interlinked temporal and spatial elements within integrated sensor data enables a tremendous degree of flexibility when analyzing multi-component datasets. The presentation illustrates how to warehouse, process, and analyze high-resolution integrated sensor datasets to support complex system analysis at the entity and system levels. The example cases presented utilizes in-vehicle sensor system data to assess vehicle performance, while integrating a map matching algorithm to link vehicle data to roads to demonstrate the enhanced analysis possible via interlinking data elements. Furthermore, in addition to the flexibility provided, the examples presented illustrate concepts of maintaining proprietary operational information (Fleet DNA) and privacy of study participants (Transportation Secure Data Center) while producing widely distributed data products. Should real-time operational data be logged at high resolution across multiple infrastructure types, map matched to their associated infrastructure, and distributed employing a similar approach; dependencies between urban environment infrastructures components could be better understood. This understanding is especially crucial for the cities of the future where transportation will rely more on grid infrastructure to support its energy demands.

  12. Growth mechanisms, polytypism, and real structure of kaolinite microcrystals

    SciTech Connect (OSTI)

    Samotoin, N. D.

    2008-09-15

    The mechanisms of growth of kaolinite microcrystals (0.1-5.0 {mu}m in size) at deposits related to the cluvial weathering crust, as well as to the low-temperature and medium-temperature hydrothermal processes of transformations of minerals in different rocks in Russia, Kazakhstan, Ukraine, Czechia, Vietnam, India, Cuba, and Madagascar, are investigated using transmission electron microscopy and vacuum decoration with gold. It is established that kaolinite microcrystals grow according to two mechanisms: the mechanism of periodic formation of two-dimensional nuclei and the mechanism of spiral growth. The spiral growth of kaolinite microcrystals is dominant and occurs on steps of screw dislocations that differ in sign and magnitude of the Burgers vector along the c axis. The layered growth of kaolinite originates from a widespread source in the form of a step between polar (+ and -) dislocations, i.e., a growth analogue of the Frank-Read dislocation source. The density of growth screw dislocations varies over a wide range and can be as high as {approx}10{sup 9} cm{sup -2}. Layered stepped kaolinite growth pyramids for all mechanisms of growth on the (001) face of kaolinite exhibit the main features of the triclinic 1Tc and real structures of this mineral.

  13. Real-space representation of electron correlation in ?-conjugated systems

    SciTech Connect (OSTI)

    Wang, Jian E-mail: e.j.baerends@vu.nl; Baerends, Evert Jan E-mail: e.j.baerends@vu.nl

    2015-05-28

    ?-electron conjugation and aromaticity are commonly associated with delocalization and especially high mobility of the ? electrons. We investigate if also the electron correlation (pair density) exhibits signatures of the special electronic structure of conjugated systems. To that end the shape and extent of the pair density and derived quantities (exchange-correlation hole, Coulomb hole, and conditional density) are investigated for the prototype systems ethylene, hexatriene, and benzene. The answer is that the effects of ? electron conjugation are hardly discernible in the real space representations of the electron correlation. We find the xc hole to be as localized (confined to atomic or diatomic regions) in conjugated systems as in small molecules. This result is relevant for density functional theory (DFT). The potential of the electron exchange-correlation hole is the largest part of v{sub xc}, the exchange-correlation Kohn-Sham potential. So the extent of the hole directly affects the orbital energies of both occupied and unoccupied Kohn-Sham orbitals and therefore has direct relevance for the excitation spectrum as calculated with time-dependent DFT calculations. The potential of the localized xc hole is comparatively more attractive than the actual hole left behind by an electron excited from a delocalized molecular orbital of a conjugated system.

  14. Real-time algorithm for robust coincidence search

    SciTech Connect (OSTI)

    Petrovic, T.; Vencelj, M.; Lipoglavsek, M.; Gajevic, J.; Pelicon, P.

    2012-10-20

    In in-beam {gamma}-ray spectroscopy experiments, we often look for coincident detection events. Among every N events detected, coincidence search is naively of principal complexity O(N{sup 2}). When we limit the approximate width of the coincidence search window, the complexity can be reduced to O(N), permitting the implementation of the algorithm into real-time measurements, carried out indefinitely. We have built an algorithm to find simultaneous events between two detection channels. The algorithm was tested in an experiment where coincidences between X and {gamma} rays detected in two HPGe detectors were observed in the decay of {sup 61}Cu. Functioning of the algorithm was validated by comparing calculated experimental branching ratio for EC decay and theoretical calculation for 3 selected {gamma}-ray energies for {sup 61}Cu decay. Our research opened a question on the validity of the adopted value of total angular momentum of the 656 keV state (J{sup {pi}} = 1/2{sup -}) in {sup 61}Ni.

  15. Comparison of Real World Energy Consumption to Models and DOE Test Procedures

    Broader source: Energy.gov [DOE]

    This study investigates the real-world energy performance of appliances and equipment as it compares with models and test procedures.

  16. National Instruments Offers Real-Time Course on April 12 | Jefferson Lab

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    National Instruments Offers Real-Time Linux, LabVIEW Real-Time and LabView FPGA Course at JLab on April 12 For those already using LabView and wanting to learn about embedded systems, National Instruments (NI) is offering an Introduction to Real-Time and FPGA on the RIO Eval Kit. The course will be held Tuesday, April 12, from 9 a.m.-4 p.m. in CEBAF Center, room F326. In this workshop, participants will develop an embedded control system using NI LabVIEW Real-Time and LabVIEW FPGA on the RIO

  17. GAO-11-520T Federal Real Property: Progress Made on Planning...

    Broader source: Energy.gov (indexed) [DOE]

    Economic Development, Public Buildings and Emergency Management, Committee on Transportation and Infrastructure, House of Representatives FEDERAL REAL PROPERTY Progress Made on...

  18. In-Situ, Real Time Measurement of Elemental Constituents | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy In-Situ, Real Time Measurement of Elemental Constituents In-Situ, Real Time Measurement of Elemental Constituents New Laser System Provides Real-Time Measurements for Improved Product Quality Control A probe uses laser-induced breakdown spectroscopy (LIBS) to determine the elemental constituents in ferrous and non-ferrous metals, ceramics, or glass. This probe measures continuously and in-situ at any point in the melt, thus providing spatial and temporal real-time data. The probe uses

  19. Real World Demonstration of a New American Low-Head Hydropower...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real World Demonstration of a New American Low-Head Hydropower Unit Office presentation icon 69dhydrogreenhydrodemonstration12.ppt More Documents & Publications Laboratory ...

  20. A MEMS platform for in situ, real-time monitoring of electrochemically...

    Office of Scientific and Technical Information (OSTI)

    Title: A MEMS platform for in situ, real-time monitoring of electrochemically induced mechanical changes in lithium-ion battery electrodes Authors: Pomerantseva, Ekaterina ; Jung, ...

  1. GAO-15-305, DOE Real Property: Better Data and More Proactive...

    Office of Environmental Management (EM)

    DOE REAL PROPERTY Better Data and a More Proactive Approach Needed to Facilitate Property Disposal Report to the Chairman, Subcommittee on Energy and Water Development, Committee...

  2. Real-World Greenhouse Gas Emissions from a MY2010 Diesel Truck...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    from a MY2010 Diesel Truck Traveling Across the Continental United States Real-World Greenhouse Gas Emissions from a MY2010 Diesel Truck Traveling Across the Continental...

  3. NSTX-U Advances in Real-Time C++11 on Linux (Journal Article...

    Office of Scientific and Technical Information (OSTI)

    Type: Accepted Manuscript Journal Name: IEEE Transactions on Nuclear Science Additional Journal Information: Journal Volume: 62; Journal Issue: 4; Conference: 2014 IEEE-NPSS Real ...

  4. Implementation of the REAL ID Act | Y-12 National Security Complex

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    recommendations of the 911 Commission, passed the REAL ID Act in an effort to reduce fraud and deter acts of terrorism using fraudulent identification. This Act sets minimum...

  5. Real-time sub-ngstrom...

    Office of Scientific and Technical Information (OSTI)

    Real-time sub-ngstrom imaging of reversible and irreversible conformations in rhodium catalysts and graphene Kisielowski, Christian; Wang,...

  6. Method and Apparatus for In-Situ Real Time Characterization of...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Energy Storage Energy Storage Find More Like This Return to Search Method and Apparatus for In-Situ Real Time Characterization of Energy Storage and Energy Conversion Devices ...

  7. Search Method for Real-time Knowledge Discovery Modeled on the...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Search Method for Real-time Knowledge Discovery Modeled on the Human Brain Oak Ridge ... information processing properties of the human brain to computational knowledge discovery. ...

  8. Trends in Real Estate and Energy Efficiency-- Update on Program Experience

    Broader source: Energy.gov [DOE]

    Better Buildings Residential Network Program Sustainability Peer Exchange Call Series: Trends in Real Estate and Energy Efficiency, Call Slides and Discussion Summary, November 7, 2013.

  9. V-228: RealPlayer Buffer Overflow and Memory Corruption Error Let Remote

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Users Execute Arbitrary Code | Department of Energy 8: RealPlayer Buffer Overflow and Memory Corruption Error Let Remote Users Execute Arbitrary Code V-228: RealPlayer Buffer Overflow and Memory Corruption Error Let Remote Users Execute Arbitrary Code August 27, 2013 - 6:00am Addthis PROBLEM: Two vulnerabilities were reported in RealPlayer PLATFORM: RealPlayer 16.0.2.32 and prior ABSTRACT: A remote user can cause arbitrary code to be executed on the target user's system REFERENCE LINKS:

  10. TH-C-17A-07: Visualizing and Quantifying Radiation Therapy in Real-Time Using a Novel Beam Imaging Technique

    SciTech Connect (OSTI)

    Jenkins, C; Naczynski, D; Xing, L

    2014-06-15

    Purpose: Radiation therapy uses invisible high energy X-rays to treat an invisible tumor. Proper positioning of the treatment beam relative to the patient's anatomy during dose delivery is critically important to the success of treatment. We develop and characterize a novel radiation therapy beam visualization technique for real-time monitoring of patient treatment. Methods: Custom made flexible scintillator sheets were fabricated from gadolinium oxysulfide (GOS) particles that had been doped with terbium within a silicone elastomer matrix. Sheets of several thicknesses ranging from 0.3 to 1mm were prepared and tested. Sheets were exposed to megavoltage X-ray and electron beams from a Varian linac and the resulting optical signal was collected by multiple CMOS cameras placed in the treatment room. Real-time images were collected for different beam energies and dose rates. Signal intensity and SNR were calculated by processing the acquired images. Results: All signals were detectable in the presence of full room lighting and at an integration time of 45ms. Average signal intensity and SNR increased with both sheet thickness and dose rate and decreased with beam energy and incident light. For a given sheet thickness and beam energy the correlation between dose rate and signal intensity was highly linear. Increased sheet thickness or dose rate results in a linear increase in the detected signal. All results are consistent with analytical approximations. Conclusion: The technique offers a means of accurately visualizing a radiation therapy beam shape and fluence in real time. The effects of salient parameters have been characterized and will enable further optimization of the technique as it is implemented into the clinical workflow. The project described was supported by the National Center for Advancing Translational Sciences of the National Institutes of Health through UL1 TR001085.

  11. Widget:UtilityRateNamingHelper | Open Energy Information

    Open Energy Info (EERE)

    UtilityRateNamingHelper Jump to: navigation, search This widget displays the utility rate database form. For example: Widget:UtilityRateNamingHelper Retrieved from "http:...

  12. INVESTIGATION OF A DYNAMIC POWER LINE RATING CONCEPT FOR IMPROVED WIND ENERGY INTEGRATION OVER COMPLEX TERRAIN

    SciTech Connect (OSTI)

    Jake P. Gentle; Kurt S Myers; Tyler B Phillips; Inanc Senocak; Phil Anderson

    2014-08-01

    Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of power line to be based on real-time conductor temperature dependent on local weather conditions. In current practice overhead power lines are generally given a conservative rating based on worst case weather conditions. Using historical weather data collected over a test bed area, we demonstrate there is often additional transmission capacity not being utilized with the current static rating practice. We investigate a new dynamic line rating methodology using computational fluid dynamics (CFD) to determine wind conditions along transmission lines at dense intervals. Simulated results are used to determine conductor temperature by calculating the transient thermal response of the conductor under variable environmental conditions. In calculating the conductor temperature, we use both a calculation with steady-state assumption and a transient calculation. Under low wind conditions, steady-state assumption predicts higher conductor temperatures that could lead to curtailments, whereas transient calculations produce conductor temperatures that are significantly lower, implying the availability of additional transmission capacity.

  13. Analytical Improvements in PV Degradation Rate Determination

    SciTech Connect (OSTI)

    Jordan, D. C.; Kurtz, S. R.

    2011-02-01

    As photovoltaic (PV) penetration of the power grid increases, it becomes vital to know how decreased power output may affect cost over time. In order to predict power delivery, the decline or degradation rates must be determined accurately. For non-spectrally corrected data several complete seasonal cycles (typically 3-5 years) are required to obtain reasonably accurate degradation rates. In a rapidly evolving industry such a time span is often unacceptable and the need exists to determine degradation rates accurately in a shorter period of time. Occurrence of outliers and data shifts are two examples of analytical problems leading to greater uncertainty and therefore to longer observation times. In this paper we compare three methodologies of data analysis for robustness in the presence of outliers, data shifts and shorter measurement time periods.

  14. Aqueous Corrosion Rates for Waste Package Materials

    SciTech Connect (OSTI)

    S. Arthur

    2004-10-08

    The purpose of this analysis, as directed by ''Technical Work Plan for: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]), is to compile applicable corrosion data from the literature (journal articles, engineering documents, materials handbooks, or standards, and national laboratory reports), evaluate the quality of these data, and use these to perform statistical analyses and distributions for aqueous corrosion rates of waste package materials. The purpose of this report is not to describe the performance of engineered barriers for the TSPA-LA. Instead, the analysis provides simple statistics on aqueous corrosion rates of steels and alloys. These rates are limited by various aqueous parameters such as temperature (up to 100 C), water type (i.e., fresh versus saline), and pH. Corrosion data of materials at pH extremes (below 4 and above 9) are not included in this analysis, as materials commonly display different corrosion behaviors under these conditions. The exception is highly corrosion-resistant materials (Inconel Alloys) for which rate data from corrosion tests at a pH of approximately 3 were included. The waste package materials investigated are those from the long and short 5-DHLW waste packages, 2-MCO/2-DHLW waste package, and the 21-PWR commercial waste package. This analysis also contains rate data for some of the materials present inside the fuel canisters for the following fuel types: U-Mo (Fermi U-10%Mo), MOX (FFTF), Thorium Carbide and Th/U Carbide (Fort Saint Vrain [FSVR]), Th/U Oxide (Shippingport LWBR), U-metal (N Reactor), Intact U-Oxide (Shippingport PWR, Commercial), aluminum-based, and U-Zr-H (TRIGA). Analysis of corrosion rates for Alloy 22, spent nuclear fuel, defense high level waste (DHLW) glass, and Titanium Grade 7 can be found in other analysis or model reports.

  15. Real-Time Dynamic Brake Assessment Proof of Concept Final Report

    SciTech Connect (OSTI)

    Lascurain, Mary Beth; Franzese, Oscar; Capps, Gary J

    2011-11-01

    This proof-of-concept research was performed to explore the feasibility of using real-world braking data from commercial motor vehicles to make a diagnosis of brake condition similar to that of the performance-based brake tester (PBBT). This was done by determining the relationship between pressure and brake force (P-BF), compensating for the gross vehicle weight (GVW). The nature of this P-BF relationship (e.g., low braking force for a given brake application pressure) may indicate brake system problems. In order to determine the relationship between brake force and brake application pressure, a few key parameters of duty cycle information were collected. Because braking events are often brief, spanning only a few seconds, a sample rate of 10 Hz was needed. The algorithm under development required brake application pressure and speed (from which deceleration was calculated). Accurate weight estimation was also needed to properly derive the braking force from the deceleration. In order to ensure that braking force was the predominant factor in deceleration for the segments of data used in analysis, the data was screened for grade as well. Also, the analysis needed to be based on pressures above the crack pressure. The crack pressure is the pressure below which the individual brakes are not applied due the nature of the mechanical system. This value, which may vary somewhat from one wheel end to another, is approximately 10 psi. Therefore, only pressures 15 psi and above were used in the analysis. The Department of Energy s Medium Truck Duty Cycle research has indicated that under the real-world circumstances of the test vehicle brake pressures of up to approximately 30 psi can be expected. Several different types of data were collected during the testing task of this project. Constant-pressure stopping tests were conducted at several combinations of brake application pressure (15, 20, 25, and 30 psi), load conditions (moderately and fully laden), and speeds (20 and 30 mph). Data was collected at 10 Hz. Standard and stepped-pressure performance-based brake tests with brake pressure transducers were performed for each loading condition. The stepped-pressure test included the constant-pressure intervals of brake application at 15, 20, 25, and 30 psi. The PBBT data files included 10 Hz streaming data collected during the testing of each axle. Two weeks of real-world duty cycle (driving and braking) data was also collected at 10 Hz. Initial analysis of the data revealed that the data collected in the field (i.e., day-to-day operations) provided the same information as that obtained from the controlled tests. Analysis of the data collected revealed a strong linear relationship between brake application pressure and deceleration for given GVWs. As anticipated, initial speed was not found to be a significant factor in the deceleration-pressure relationship, unlike GVW. The positive results obtained from this proof of concept test point to the need for further research to expand this concept. A second phase should include testing over a wider range of speeds and include medium brake application pressures in addition to the low pressures tested in this research. Testing on multiple vehicles would also be of value. This future phase should involve testing to determine how degradation of braking performance affects the pressure-deceleration relationship.

  16. DOE - NNSA/NFO -- Rate our Site

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rate our Site U.S. DOE/NNSA - Nevada Field Office Rate our website The Nevada Field Office is committed to providing high-quality products and services that meet your needs. Your participation in our customer satisfaction survey will help us achieve this goal. NFO would appreciate your taking the time to complete this survey. Responses are confidential. The survey should take approximately 15 minutes or 1 minute per question. You do not have to answers all the questions. How did you feel working

  17. NSTX-U Advances in Real-Time C++11 on Linux

    SciTech Connect (OSTI)

    Erickson, Keith G.

    2015-08-14

    Programming languages like C and Ada combined with proprietary embedded operating systems have dominated the real-time application space for decades. The new C++11standard includes native, language-level support for concurrency, a required feature for any nontrivial event-oriented real-time software. Threads, Locks, and Atomics now exist to provide the necessary tools to build the structures that make up the foundation of a complex real-time system. The National Spherical Torus Experiment Upgrade (NSTX-U) at the Princeton Plasma Physics Laboratory (PPPL) is breaking new ground with the language as applied to the needs of fusion devices. A new Digital Coil Protection System (DCPS) will serve as the main protection mechanism for the magnetic coils, and it is written entirely in C++11 running on Concurrent Computer Corporation's real-time operating system, RedHawk Linux. It runs over 600 algorithms in a 5 kHz control loop that determine whether or not to shut down operations before physical damage occurs. To accomplish this, NSTX-U engineers developed software tools that do not currently exist elsewhere, including real-time atomic synchronization, real-time containers, and a real-time logging framework. Together with a recent (and carefully configured) version of the GCC compiler, these tools enable data acquisition, processing, and output using a conventional operating system to meet a hard real-time deadline (that is, missing one periodic is a failure) of 200 microseconds.

  18. Improved AST's Based on Real World FCV Data | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Improved AST's Based on Real World FCV Data Improved AST's Based on Real World FCV Data Presented at the Department of Energy Fuel Cell Projects Kickoff Meeting, September 1 - October 1, 2009 PDF icon madden_utc_kickoff.pdf More Documents & Publications Fuel Cell Projects Kickoff Meeting Accelerated Testing Validation FC-PAD Organization and Activities

  19. NSTX-U Advances in Real-Time C++11 on Linux

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Erickson, Keith G.

    2015-08-14

    Programming languages like C and Ada combined with proprietary embedded operating systems have dominated the real-time application space for decades. The new C++11standard includes native, language-level support for concurrency, a required feature for any nontrivial event-oriented real-time software. Threads, Locks, and Atomics now exist to provide the necessary tools to build the structures that make up the foundation of a complex real-time system. The National Spherical Torus Experiment Upgrade (NSTX-U) at the Princeton Plasma Physics Laboratory (PPPL) is breaking new ground with the language as applied to the needs of fusion devices. A new Digital Coil Protection System (DCPS) willmore »serve as the main protection mechanism for the magnetic coils, and it is written entirely in C++11 running on Concurrent Computer Corporation's real-time operating system, RedHawk Linux. It runs over 600 algorithms in a 5 kHz control loop that determine whether or not to shut down operations before physical damage occurs. To accomplish this, NSTX-U engineers developed software tools that do not currently exist elsewhere, including real-time atomic synchronization, real-time containers, and a real-time logging framework. Together with a recent (and carefully configured) version of the GCC compiler, these tools enable data acquisition, processing, and output using a conventional operating system to meet a hard real-time deadline (that is, missing one periodic is a failure) of 200 microseconds.« less

  20. NSTX-U Advances in Real-Time C++11 on Linux

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Erickson, Keith G.

    2015-08-14

    Programming languages like C and Ada combined with proprietary embedded operating systems have dominated the real-time application space for decades. The new C++11standard includes native, language-level support for concurrency, a required feature for any nontrivial event-oriented real-time software. Threads, Locks, and Atomics now exist to provide the necessary tools to build the structures that make up the foundation of a complex real-time system. The National Spherical Torus Experiment Upgrade (NSTX-U) at the Princeton Plasma Physics Laboratory (PPPL) is breaking new ground with the language as applied to the needs of fusion devices. A new Digital Coil Protection System (DCPS) willmore » serve as the main protection mechanism for the magnetic coils, and it is written entirely in C++11 running on Concurrent Computer Corporation's real-time operating system, RedHawk Linux. It runs over 600 algorithms in a 5 kHz control loop that determine whether or not to shut down operations before physical damage occurs. To accomplish this, NSTX-U engineers developed software tools that do not currently exist elsewhere, including real-time atomic synchronization, real-time containers, and a real-time logging framework. Together with a recent (and carefully configured) version of the GCC compiler, these tools enable data acquisition, processing, and output using a conventional operating system to meet a hard real-time deadline (that is, missing one periodic is a failure) of 200 microseconds.« less

    1. Business Models and Case Examples for Working with the Real Estate Sector

      Broader source: Energy.gov [DOE]

      Better Buildings Neighborhood Program: Business Models and Case Examples for Working with the Real Estate Sector, May 10, 2012: A discussion of business models and case examples for working with the real estate sector. Call Slides and Discussion Summary, May 10, 2012.

    2. Non-intrusive, high-resolution, real-time, two-dimensional imaging of multiphase materials using acoustic array sensors

      SciTech Connect (OSTI)

      Cassiède, M.; Shaw, J. M.

      2015-04-15

      Two parallel multi-element ultrasonic acoustic arrays combined with sets of focal laws for acoustic signal generation and a classical tomographic inversion algorithm are used to generate real-time two-dimensional micro seismic acoustic images of multiphase materials. Proof of concept and calibration measurements were performed for single phase and two phase liquids, uniform polyvinyl chloride (PVC) plates, and aluminum cylinders imbedded in PVC plates. Measurement artefacts, arising from the limited range of viewing angles, and the compromise between data acquisition rate and image quality are discussed. The angle range of scanning and the image resolution were varied, and the effects on the quality of the reproduction of the speed of sound profiles of model solids and liquids with known geometries and compositions were analysed in detail. The best image quality results were obtained for a scanning angle range of [−35°, 35°] at a step size of 2.5° post processed to generate images on a 40 μm square grid. The data acquisition time for high quality images with a 30 mm × 40 mm view field is 10 min. Representation of two-phase solids with large differences in speed of sound between phases and where one phase is dispersed in the form of macroscopic objects (greater than 1 mm in diameter) proved to be the most difficult to image accurately. Liquid-liquid and liquid-vapor phase boundaries, in micro porous solids by contrast, were more readily defined. Displacement of air by water and water by heptane in natural porous limestone provides illustrative kinetic examples. Measurement results with these realistic cases demonstrate the feasibility of the technique to monitor in real time and on the micrometer length scale local composition and flow of organic liquids in inorganic porous media, one of many envisioned engineering applications. Improvement of data acquisition rate is an area for future collaborative study.

    3. Front-end utility rate updates | OpenEI Community

      Open Energy Info (EERE)

      Front-end utility rate updates Home > Groups > Utility Rate Rmckeel's picture Submitted by Rmckeel(297) Contributor 13 February, 2013 - 14:28 Utility Rates A few utility rate...

    4. Overview of Field Experience - Degradation Rates & Lifetimes

      SciTech Connect (OSTI)

      Jordan, Dirk; Kurtz, Sarah

      2015-09-14

      The way a PV module fails may depend not only on its design and the materials used in its construction, but also on the weather it experiences, the way it is mounted, and the quality control during its manufacture. This presentation gives an overview of Field Experience - what degradation rates and what lifetimes are being observed in various regions.

    5. The Distant Type Ia Supernova Rate

      DOE R&D Accomplishments [OSTI]

      Pain, R.; Fabbro, S.; Sullivan, M.; Ellis, R. S.; Aldering, G.; Astier, P.; Deustua, S. E.; Fruchter, A. S.; Goldhaber, G.; Goobar, A.; Groom, D. E.; Hardin, D.; Hook, I. M.; Howell, D. A.; Irwin, M. J.; Kim, A. G.; Kim, M. Y.; Knop, R. A.; Lee, J. C.; Perlmutter, S.; Ruiz-Lapuente, P.; Schahmaneche, K.; Schaefer, B.; Walton, N. A.

      2002-05-28

      We present a measurement of the rate of distant Type Ia supernovae derived using 4 large subsets of data from the Supernova Cosmology Project. Within this fiducial sample, which surveyed about 12 square degrees, thirty-eight supernovae were detected at redshifts 0.25--0.85. In a spatially flat cosmological model consistent with the results obtained by the Supernova Cosmology Project, we derive a rest-frame Type Ia supernova rate at a mean red shift z {approx_equal} 0.55 of 1.53 {sub -0.25}{sub -0.31}{sup 0.28}{sup 0.32} x 10{sup -4} h{sup 3} Mpc{sup -3} yr{sup -1} or 0.58{sub -0.09}{sub -0.09}{sup +0.10}{sup +0.10} h{sup 2} SNu(1 SNu = 1 supernova per century per 10{sup 10} L{sub B}sun), where the first uncertainty is statistical and the second includes systematic effects. The dependence of the rate on the assumed cosmological parameters is studied and the redshift dependence of the rate per unit comoving volume is contrasted with local estimates in the context of possible cosmic star formation histories and progenitor models.

    6. WP-96/TR-96 & TC-96 Power and Transmission Rate Case (rates/ratecases...

      Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

      Of Decision (WP-96 ROD) Final Studies And Documentation (WP-96-FS) Loads and Resources Revenue Requirement Segmentation Marginal Cost Analysis Wholesale Power Rate Development...

    7. U.S. Utility Rate Database - U.S. Utility Rate Database

      Open Energy Info (EERE)

      As Of Today ApprovedUnapproved All Approved Only Unapproved Only Order By Latest Update Utility Name Rate Name Sector Approval Staus Effective Date End Date Display Results...

    8. Real-Time Active Cosmic Neutron Background Reduction Methods

      SciTech Connect (OSTI)

      Mukhopadhyay, Sanjoy; Maurer, Richard; Wolff, Ronald; Mitchell, Stephen; Guss, Paul

      2013-09-01

      Neutron counting using large arrays of pressurized 3He proportional counters from an aerial system or in a maritime environment suffers from the background counts from the primary cosmic neutrons and secondary neutrons caused by cosmic ray?induced mechanisms like spallation and charge-exchange reaction. This paper reports the work performed at the Remote Sensing LaboratoryAndrews (RSL-A) and results obtained when using two different methods to reduce the cosmic neutron background in real time. Both methods used shielding materials with a high concentration (up to 30% by weight) of neutron-absorbing materials, such as natural boron, to remove the low-energy neutron flux from the cosmic background as the first step of the background reduction process. Our first method was to design, prototype, and test an up-looking plastic scintillator (BC-400, manufactured by Saint Gobain Corporation) to tag the cosmic neutrons and then create a logic pulse of a fixed time duration (~120 ?s) to block the data taken by the neutron counter (pressurized 3He tubes running in a proportional counter mode). The second method examined the time correlation between the arrival of two successive neutron signals to the counting array and calculated the excess of variance (Feynman variance Y2F)1 in the neutron count distribution from Poisson distribution. The dilution of this variance from cosmic background values ideally would signal the presence of man-made neutrons.2 The first method has been technically successful in tagging the neutrons in the cosmic-ray flux and preventing them from being counted in the 3He tube array by electronic vetofield measurement work shows the efficiency of the electronic veto counter to be about 87%. The second method has successfully derived an empirical relationship between the percentile non-cosmic component in a neutron flux and the Y2F of the measured neutron count distribution. By using shielding materials alone, approximately 55% of the neutron flux from man-made sources like 252Cf or Am-Be was removed.

    9. Optimal Real-time Dispatch for Integrated Energy Systems

      SciTech Connect (OSTI)

      Firestone, Ryan Michael

      2007-05-31

      This report describes the development and application of a dispatch optimization algorithm for integrated energy systems (IES) comprised of on-site cogeneration of heat and electricity, energy storage devices, and demand response opportunities. This work is intended to aid commercial and industrial sites in making use of modern computing power and optimization algorithms to make informed, near-optimal decisions under significant uncertainty and complex objective functions. The optimization algorithm uses a finite set of randomly generated future scenarios to approximate the true, stochastic future; constraints are included that prevent solutions to this approximate problem from deviating from solutions to the actual problem. The algorithm is then expressed as a mixed integer linear program, to which a powerful commercial solver is applied. A case study of United States Postal Service Processing and Distribution Centers (P&DC) in four cities and under three different electricity tariff structures is conducted to (1) determine the added value of optimal control to a cogeneration system over current, heuristic control strategies; (2) determine the value of limited electric load curtailment opportunities, with and without cogeneration; and (3) determine the trade-off between least-cost and least-carbon operations of a cogeneration system. Key results for the P&DC sites studied include (1) in locations where the average electricity and natural gas prices suggest a marginally profitable cogeneration system, optimal control can add up to 67% to the value of the cogeneration system; optimal control adds less value in locations where cogeneration is more clearly profitable; (2) optimal control under real-time pricing is (a) more complicated than under typical time-of-use tariffs and (b) at times necessary to make cogeneration economic at all; (3) limited electric load curtailment opportunities can be more valuable as a compliment to the cogeneration system than alone; and (4) most of the trade-off between least-cost and least-carbon IES is determined during the system design stage; for the IES system considered, there is little difference between least-cost control and least-carbon control.

    10. A real two-phase submarine debris flow and tsunami

      SciTech Connect (OSTI)

      Pudasaini, Shiva P.; Miller, Stephen A.

      2012-09-26

      The general two-phase debris flow model proposed by Pudasaini is employed to study subaerial and submarine debris flows, and the tsunami generated by the debris impact at lakes and oceans. The model, which includes three fundamentally new and dominant physical aspects such as enhanced viscous stress, virtual mass, and generalized drag (in addition to buoyancy), constitutes the most generalized two-phase flow model to date. The advantage of this two-phase debris flow model over classical single-phase, or quasi-two-phase models, is that the initial mass can be divided into several parts by appropriately considering the solid volume fraction. These parts include a dry (landslide or rock slide), a fluid (water or muddy water; e.g., dams, rivers), and a general debris mixture material as needed in real flow simulations. This innovative formulation provides an opportunity, within a single framework, to simultaneously simulate the sliding debris (or landslide), the water lake or ocean, the debris impact at the lake or ocean, the tsunami generation and propagation, the mixing and separation between the solid and fluid phases, and the sediment transport and deposition process in the bathymetric surface. Applications of this model include (a) sediment transport on hill slopes, river streams, hydraulic channels (e.g., hydropower dams and plants); lakes, fjords, coastal lines, and aquatic ecology; and (b) submarine debris impact and the rupture of fiber optic, submarine cables and pipelines along the ocean floor, and damage to offshore drilling platforms. Numerical simulations reveal that the dynamics of debris impact induced tsunamis in mountain lakes or oceans are fundamentally different than the tsunami generated by pure rock avalanches and landslides. The analysis includes the generation, amplification and propagation of super tsunami waves and run-ups along coastlines, debris slide and deposition at the bottom floor, and debris shock waves. It is observed that the submarine debris speed can be faster than the tsunami speed. This information can be useful for early warning strategies in the coastal regions. These findings substantially increase our understanding of complex multi-phase systems and multi-physics and flows, and allows for the proper modeling of landslide and debris induced tsunami, the dynamics of turbidity currents and sediment transport, and the associated applications to hazard mitigation, geomorphology and sedimentology.

    11. A jet fuel surrogate formulated by real fuel properties

      SciTech Connect (OSTI)

      Dooley, Stephen; Won, Sang Hee; Chaos, Marcos; Heyne, Joshua; Ju, Yiguang; Dryer, Frederick L.; Kumar, Kamal; Sung, Chih-Jen; Wang, Haowei; Oehlschlaeger, Matthew A.; Santoro, Robert J.; Litzinger, Thomas A.

      2010-12-15

      An implicit methodology based on chemical group theory to formulate a jet aviation fuel surrogate by the measurements of several combustion related fuel properties is tested. The empirical formula and derived cetane number of an actual aviation fuel, POSF 4658, have been determined. A three component surrogate fuel for POSF 4658 has been formulated by constraining a mixture of n-decane, iso-octane and toluene to reproduce the hydrogen/carbon ratio and derived cetane number of the target fuel. The validity of the proposed surrogate is evaluated by experimental measurement of select combustion properties of POSF 4658, and the POSF 4658 surrogate. (1)A variable pressure flow reactor has been used to chart the chemical reactivity of stoichiometric mixtures of POSF 4658/O{sub 2}/N{sub 2} and POSF 4658 surrogate/O{sub 2}/N{sub 2} at 12.5 atm and 500-1000 K, fixing the carbon content at 0.3% for both mixtures. (2)The high temperature chemical reactivity and chemical kinetic-molecular diffusion coupling of POSF 4658 and POSF 4658 surrogate have been evaluated by measurement of the strained extinction limit of diffusion flames. (3)The autoignition behavior of POSF 4658 and POSF 4658 surrogate has been measured with a shock tube at 674-1222 K and with a rapid compression machine at 645-714 K for stoichiometric mixtures of fuel in air at pressures close to 20 atm. The flow reactor study shows that the character and extent of chemical reactivity of both fuels at low temperature (500-675 K) and high temperature (900 K+) are extremely similar. Slight differences in the transition from the end of the negative temperature coefficient regime to hot ignition are observed. The diffusion flame strained extinction limits of the fuels are observed to be indistinguishable when compared on a molar basis. Ignition delay measurements also show that POSF 4658 exhibits NTC behavior. Moreover, the ignition delays of both fuels are also extremely similar over the temperature range studied in both shock tube and rapid compression machine experiments. A chemical kinetic model is constructed and utilized to interpret the experimental observations and provides a rationale as to why the real fuel and surrogate fuel exhibit such similar reactivity. (author)

    12. Analysis of real-time reservoir monitoring : reservoirs, strategies, & modeling.

      SciTech Connect (OSTI)

      Mani, Seethambal S.; van Bloemen Waanders, Bart Gustaaf; Cooper, Scott Patrick; Jakaboski, Blake Elaine; Normann, Randy Allen; Jennings, Jim; Gilbert, Bob; Lake, Larry W.; Weiss, Chester Joseph; Lorenz, John Clay; Elbring, Gregory Jay; Wheeler, Mary Fanett; Thomas, Sunil G.; Rightley, Michael J.; Rodriguez, Adolfo; Klie, Hector; Banchs, Rafael; Nunez, Emilio J.; Jablonowski, Chris

      2006-11-01

      The project objective was to detail better ways to assess and exploit intelligent oil and gas field information through improved modeling, sensor technology, and process control to increase ultimate recovery of domestic hydrocarbons. To meet this objective we investigated the use of permanent downhole sensors systems (Smart Wells) whose data is fed real-time into computational reservoir models that are integrated with optimized production control systems. The project utilized a three-pronged approach (1) a value of information analysis to address the economic advantages, (2) reservoir simulation modeling and control optimization to prove the capability, and (3) evaluation of new generation sensor packaging to survive the borehole environment for long periods of time. The Value of Information (VOI) decision tree method was developed and used to assess the economic advantage of using the proposed technology; the VOI demonstrated the increased subsurface resolution through additional sensor data. Our findings show that the VOI studies are a practical means of ascertaining the value associated with a technology, in this case application of sensors to production. The procedure acknowledges the uncertainty in predictions but nevertheless assigns monetary value to the predictions. The best aspect of the procedure is that it builds consensus within interdisciplinary teams The reservoir simulation and modeling aspect of the project was developed to show the capability of exploiting sensor information both for reservoir characterization and to optimize control of the production system. Our findings indicate history matching is improved as more information is added to the objective function, clearly indicating that sensor information can help in reducing the uncertainty associated with reservoir characterization. Additional findings and approaches used are described in detail within the report. The next generation sensors aspect of the project evaluated sensors and packaging survivability issues. Our findings indicate that packaging represents the most significant technical challenge associated with application of sensors in the downhole environment for long periods (5+ years) of time. These issues are described in detail within the report. The impact of successful reservoir monitoring programs and coincident improved reservoir management is measured by the production of additional oil and gas volumes from existing reservoirs, revitalization of nearly depleted reservoirs, possible re-establishment of already abandoned reservoirs, and improved economics for all cases. Smart Well monitoring provides the means to understand how a reservoir process is developing and to provide active reservoir management. At the same time it also provides data for developing high-fidelity simulation models. This work has been a joint effort with Sandia National Laboratories and UT-Austin's Bureau of Economic Geology, Department of Petroleum and Geosystems Engineering, and the Institute of Computational and Engineering Mathematics.

    13. Real-time characterization of partially observed epidemics using surrogate models.

      SciTech Connect (OSTI)

      Safta, Cosmin; Ray, Jaideep; Lefantzi, Sophia; Crary, David; Sargsyan, Khachik; Cheng, Karen

      2011-09-01

      We present a statistical method, predicated on the use of surrogate models, for the 'real-time' characterization of partially observed epidemics. Observations consist of counts of symptomatic patients, diagnosed with the disease, that may be available in the early epoch of an ongoing outbreak. Characterization, in this context, refers to estimation of epidemiological parameters that can be used to provide short-term forecasts of the ongoing epidemic, as well as to provide gross information on the dynamics of the etiologic agent in the affected population e.g., the time-dependent infection rate. The characterization problem is formulated as a Bayesian inverse problem, and epidemiological parameters are estimated as distributions using a Markov chain Monte Carlo (MCMC) method, thus quantifying the uncertainty in the estimates. In some cases, the inverse problem can be computationally expensive, primarily due to the epidemic simulator used inside the inversion algorithm. We present a method, based on replacing the epidemiological model with computationally inexpensive surrogates, that can reduce the computational time to minutes, without a significant loss of accuracy. The surrogates are created by projecting the output of an epidemiological model on a set of polynomial chaos bases; thereafter, computations involving the surrogate model reduce to evaluations of a polynomial. We find that the epidemic characterizations obtained with the surrogate models is very close to that obtained with the original model. We also find that the number of projections required to construct a surrogate model is O(10)-O(10{sup 2}) less than the number of samples required by the MCMC to construct a stationary posterior distribution; thus, depending upon the epidemiological models in question, it may be possible to omit the offline creation and caching of surrogate models, prior to their use in an inverse problem. The technique is demonstrated on synthetic data as well as observations from the 1918 influenza pandemic collected at Camp Custer, Michigan.

    14. EDC-37 Deflagration Rates at Elevated Pressures

      SciTech Connect (OSTI)

      Maienschein, J L; Koerner, J G

      2008-01-31

      We report deflagration rates on EDC-37 at high pressures. Experiments are conducted using the Lawrence Livermore National Laboratory High Pressure Strand Burner (HPSB) apparatus. The HPSB contains a deflagrating sample in a small volume, high pressure chamber. The sample consists of nine, 6.35 mm diameter, 6.35 mm length cylinders stacked on end, with burn wires placed between cylinders. Sample deflagration is limited to the cross-sectional surface of the cylinder by coating the cylindrical surface of the tower with Halthane 88-2 epoxy. Sample deflagration is initiated on one end of the tower by a B/KNO{sub 3} and HNS igniter train. Simultaneous temporal pressure history and burn front time of arrival measurements yield the laminar deflagration rate for a range of pressures and provide insight into deflagration uniformity. These measurements are one indicator of overall thermal explosion violence. Specific details of the experiment and the apparatus can be found in the literature.

    15. Feed rate measuring method and system

      DOE Patents [OSTI]

      Novak, James L. (Albuquerque, NM); Wiczer, James J. (Albuquerque, NM)

      1995-01-01

      A system and method are provided for establishing the feed rate of a workpiece along a feed path with respect to a machine device. First and second sensors each having first and second sensing electrodes which are electrically isolated from the workpiece are positioned above, and in proximity to the desired surfaces of the workpiece along a feed path. An electric field is developed between the first and second sensing electrodes of each sensor and capacitance signals are developed which are indicative of the contour of the workpiece. First and second image signals representative of the contour of the workpiece along the feed path are developed by an image processor. The time delay between corresponding portions of the first and second image signals are then used to determine the feed rate based upon the separation of the first and second sensors and the amount of time between corresponding portions of the first and second image signals.

    16. Predict carbonation rate on iron catalyst

      SciTech Connect (OSTI)

      Dry, M.E.

      1980-02-01

      On solely thermodynamic grounds, the main hydrocarbon product of the Fischer-Tropsch reaction should be methane; in practice, however, carbon is frequently produced as well and deposited on the iron catalyst, fouling the active surface sites. South African Coal, Oil and Gas Corp., Ltd.'s experiments with a fluidized Fischer-Tropsch catalyst bed demonstrate that the rate of carbon deposition is strongly dependent on the hydrogen partial pressure in the reactor, much less dependent on the CO pressure, and not affected at all by the pressure of CO/sub 2/. A suggested reaction scheme for the Fischer-Tropsch synthesis explains these observations and provides a basis for a correlation useful in predicting carbon-deposition rates.

    17. Consumers face $5. 9 million rate increase

      SciTech Connect (OSTI)

      Not Available

      1984-11-01

      Testimony at hearings before the Garrison Diversion Compromise Commission claimed that rural consumers in the Upper Midwest could face $5.9 million in electric rate increases if the commission deauthorizes the project and hydroelectric rates go up to pay the costs of the 1944 Pick-Sloan project originally assigned to irrigation. If there is no irrigation development, the revenue that irrigation must raise to repay the $67 million debt assigned to irrigation must be reassigned to hydroelectric power. The commission represents a compromise between supporters and opponents of the Garrison Diversion project. Spokesmen for regional utilities spoke in support of the project as an investment whose costs have escalated because of delays at the expense of economic development in North Dakota.

    18. Feed rate measuring method and system

      DOE Patents [OSTI]

      Novak, J.L.; Wiczer, J.J.

      1995-12-05

      A system and method are provided for establishing the feed rate of a workpiece along a feed path with respect to a machine device. First and second sensors each having first and second sensing electrodes which are electrically isolated from the workpiece are positioned above, and in proximity to the desired surfaces of the workpiece along a feed path. An electric field is developed between the first and second sensing electrodes of each sensor and capacitance signals are developed which are indicative of the contour of the workpiece. First and second image signals representative of the contour of the workpiece along the feed path are developed by an image processor. The time delay between corresponding portions of the first and second image signals are then used to determine the feed rate based upon the separation of the first and second sensors and the amount of time between corresponding portions of the first and second image signals. 18 figs.

    19. Real-time graphic display utility for nuclear safety applications

      SciTech Connect (OSTI)

      Yang, S.; Huang, X.; Taylor, J.; Stevens, J.; Gerardis, T.; Hsu, A.; McCreary, T.

      2006-07-01

      With the increasing interests in the nuclear energy, new nuclear power plants will be constructed and licensed, and older generation ones will be upgraded for assuring continuing operation. The tendency of adopting the latest proven technology and the fact of older parts becoming obsolete have made the upgrades imperative. One of the areas for upgrades is the older CRT display being replaced by the latest graphics displays running under modern real time operating system (RTOS) with safety graded modern computer. HFC has developed a graphic display utility (GDU) under the QNX RTOS. A standard off-the-shelf software with a long history of performance in industrial applications, QNX RTOS used for safety applications has been examined via a commercial dedication process that is consistent with the regulatory guidelines. Through a commercial survey, a design life cycle and an operating history evaluation, and necessary tests dictated by the dedication plan, it is reasonably confirmed that the QNX RTOS was essentially equivalent to what would be expected in the nuclear industry. The developed GDU operates and communicates with the existing equipment through a dedicated serial channel of a flat panel controller (FPC) module. The FPC module drives a flat panel display (FPD) monitor. A touch screen mounted on the FPD serves as the normal operator interface with the FPC/FPD monitor system. The GDU can be used not only for replacing older CRTs but also in new applications. The replacement of the older CRT does not disturb the function of the existing equipment. It not only provides modern proven technology upgrade but also improves human ergonomics. The FPC, which can be used as a standalone controller running with the GDU, is an integrated hardware and software module. It operates as a single board computer within a control system, and applies primarily to the graphics display, targeting, keyboard and mouse. During normal system operation, the GDU has two sources of data input: a serial interface with field equipment and a serial input from the FPD touch screen. The mechanism for data collection from the field equipment consists of the regular exchange of the data update request messages and target commands sent to the equipment and the update messages returned to the FPC. The data updates from field equipment control displays presented on the graphic pages. Touch screen contacts are decoded to identify physical position that was contacted. If that position corresponds with one of the buttons on the graphic page, the software uses that input to initiate the function defined for the particular button contacted. In this paper, the FPC will be illustrated as a standalone system as well as a module in a dedicated control system. The GDU design concepts and its design flow will be demonstrated. The dedication process of the QNX RTOS needed for the GDU will be highlighted. Finally, the GDU with a specific application example used in one of the nuclear power plants will be presented. (authors)

    20. Subsurface heaters with low sulfidation rates

      DOE Patents [OSTI]

      John, Randy Carl; Vinegar, Harold J

      2013-12-10

      A system for heating a hydrocarbon containing formation includes a heater having an elongated ferromagnetic metal heater section. The heater is located in an opening in a formation. The heater section is configured to heat the hydrocarbon containing formation. The exposed ferromagnetic metal has a sulfidation rate that goes down with increasing temperature of the heater, when the heater is in a selected temperature range.