Instantaneous gas water heater  

SciTech Connect

Hot water supply temperature is set by a temperature setting device in response to an instantaneous flow rate signal from a water flow rate sensor arranged in a water supply pipe and a feeding water temperature signal from a feeding water temperature sensor which are compared with a predetermined hot water supply temperature and calculated in a control unit. A proportional valve and other devices in a gas supply pipe are controlled in response to the result of the comparison and calculation to define a required volume of gas for ignition and heating. At the same time, a fan damper is controlled by a damper control device so as to adjust the volume of combustion air. A signal representing discharging hot water temperature from a discharging hot water temperature sensor arranged in a hot water feeding pipe is fed back to the control unit and calculated therein, and a valve in the hot water supply pipe is adjusted in response to the result of calculation to attain the desired hot water supply temperature. In order to prevent freezing in the system in winter season, a signal from a thermostat in the water feeding pipe is transmitted to a heater arranged in an air supply chamber so as to heat a heat exchanger pipe and, at the same time, heaters arranged in the water feeding pipe and the hot water supply pipe are also controlled to prevent freezing.

Tsutsui, O.; Kuwahara, H.; Murakami, Sh.; Yasunaga, Sh.

1985-02-26T23:59:59.000Z

2

SC: Gas Heater | The Better Buildings Alliance  

NLE Websites -- All DOE Office Websites (Extended Search)

Space Conditioning Install a gas heater that uses 10% less energy using the gas heater specification Activities Technology Solutions Teams Lighting & Electrical Space...

3

Oil and Gas Air Heaters  

E-Print Network (OSTI)

Most conventional air heaters adopt indirect heat transfer, which uses combustion gases to indirectly heat fresh air by heating surfaces to generate hot air used for material drying and dehumidification. We call them indirect air heaters. However, they have a higher manufacturing cost and lower thermal efficiency, especially when high temperature air is needed. For this reason, a direct air heater applicable for or feed and industrial raw products is put forward, which has advantages such as less production cost, smaller dimensions and higher thermal efficiency. Their design, working principles, characteristics, structure and applications are presented in this article, and brief comparisons are made between the indirect and direct air heater. Finally, the relation of hot-air temperature, oil or gas consumption and fresh airflow is determined based on energy equilibrium.

Kou, G.; Wang, H.; Zhou, J.

2006-01-01T23:59:59.000Z

4

Gas Swimming Pool Heaters | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

can be a good choice for pools that aren't used on a regular basis. Unlike heat pump and solar pool heaters, gas pool heaters can maintain any desired temperature regardless of...

5

Gas Water Heater Energy Losses  

E-Print Network (OSTI)

analyses of storage-type water heaters. 2 TANK modelswater heater as part of the DOE rulemaking analysis. We used the most current version of this model--

Biermayer, Peter

2012-01-01T23:59:59.000Z

6

Economics of Residential Gas Furnaces and Water Heaters in United...  

NLE Websites -- All DOE Office Websites (Extended Search)

single-family home construction market, the choice of what gas furnace and gas water heater combination to install is primarily driven by first cost considerations. In this...

7

Research and Application of the Natural Gas Heater  

Science Conference Proceedings (OSTI)

The natural gas heater is an indispensable piece of equipment in natural gas production, transmission, and application systems and is widely used in gas wellhead, metering station, transfer station and gas power plant etc. As a special type of furnace, ... Keywords: energy science and technology, natural gas heater, flow field organization, large cylinder, heat-transfer medium

Guo Yun; Cao Wei-wu

2009-10-01T23:59:59.000Z

8

Gas Turbine Fired Heater Integration: Achieve Significant Energy Savings  

E-Print Network (OSTI)

Faster payout will result if gas turbine exhaust is used as combustion air for fired heaters. Here are economic examples and system design considerations.

Iaquaniello, G.; Pietrogrande, P.

1985-05-01T23:59:59.000Z

9

Commercial Gas Water Heaters, Purchasing Specifications for Energy-Efficient Products (Fact Sheet)  

Science Conference Proceedings (OSTI)

Performance and purchasing specifications for commercial gas water heaters under the FEMP-designated product program.

Not Available

2010-09-01T23:59:59.000Z

10

Covered Product Category: Gas Storage Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Gas Storage Water Heaters Gas Storage Water Heaters Covered Product Category: Gas Storage Water Heaters October 7, 2013 - 10:43am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STARÂź-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

11

Economics of residential gas furnaces and water heaters in US new construction market  

E-Print Network (OSTI)

appliance_standards/residential/water_ pool_heaters_prelim_Star (2008). Energy star residential water heaters: Finalefficiency improvements for residential gas furnaces in the

Lekov, Alex B.; Franco, Victor H.; Wong-Parodi, Gabrielle; McMahon, James E.; Chan, Peter

2010-01-01T23:59:59.000Z

12

Gas Swimming Pool Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You'll probably need to tune up your pool heater annually. Also, scaling in the burner or heat exchanger may decrease efficiency over a period of time. With proper installation and...

13

Small Space Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Small Space Heater Basics Small Space Heater Basics Small Space Heater Basics August 19, 2013 - 10:38am Addthis Small space heaters, also called portable heaters, are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. Space heater capacities generally range between 10,000 Btu to 40,000 Btu per hour. Common fuels used for this purpose are electricity, propane, natural gas, and kerosene. Although most space heaters rely on convection (the circulation of air in a room), some rely on radiant heating; that is, they emit infrared radiation that directly heats up objects and people that are within their line of sight. Combustion Space Heaters Space heaters are classified as vented and unvented, or "vent free." Unvented combustion units are not recommended for inside use, as they

14

FEMP Designated Product Assessment for Commercial Gas Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

FEMP Designated Product Assessment for Commercial Gas Water Heaters FEMP Designated Product Assessment for Commercial Gas Water Heaters Title FEMP Designated Product Assessment for Commercial Gas Water Heaters Publication Type Report LBNL Report Number LBNL-5514E Year of Publication 2010 Authors Lutz, James D. Subsidiary Authors Energy Analysis Department Document Number LBNL-5514E Pagination 8 Date Published April 1 Publisher Lawrence Berkeley National Laboratory City Berkeley ISBN Number LBNL-5514E Abstract None Notes This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. Attachment Size PDF 240.22 KB Google Scholar BibTex RIS RTF XML Alternate URL: http://eetd.lbl.gov/node/50317

15

Whole-Home Gas Tankless Water Heaters, Purchasing Specifications for Energy-Efficient Products (Fact Sheet)  

SciTech Connect

Performance and purchasing specifications for whole-home gas water heaters under the FEMP-designated product program.

2010-06-01T23:59:59.000Z

16

Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater  

NLE Websites -- All DOE Office Websites (Extended Search)

Gas-Fired Absorption Gas-Fired Absorption Heat Pump Water Heater Research Project to someone by E-mail Share Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Facebook Tweet about Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Twitter Bookmark Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Google Bookmark Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Delicious Rank Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Digg Find More places to share Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on AddThis.com...

17

The fluidized bed combustor-heater equipped gas fired CCGT  

Science Conference Proceedings (OSTI)

The combustion of natural gas in an atmospheric fluidized bed combined with heat transfer from the bed to the working fluid is shown to be an attractive means for supplying heat to closed cycle gas turbines. It is demonstrated how this concept can yield high thermal efficiencies without the use of high temperature resistant materials and yield low levels of pollutant emissions. The features of the combustor-heater are established for a 9000 kW closed cycle gas turbine generator and comparisons are made with a conventional open cycle machine.

Fejer, A.

1984-06-01T23:59:59.000Z

18

Fluidized bed combustor-heater equipped gas fired CCGT  

Science Conference Proceedings (OSTI)

The combustion of natural gas in an atmospheric fluidized bed combined with heat transfer from the bed to the working fluid is shown to be an attractive means for supplying heat to closed cycle gas turbines. It is demonstrated how this concept can yield high thermal efficiencies without the use of high temperature resistant materials and yield low levels of pollutant emissions. The features of the combustor-heater are established for a 9000 kW closed cycle gas turbine generator and comparisons are made with a conventional open cycle machine.

Fejer, A.A.

1984-01-01T23:59:59.000Z

19

A Gas-Fired Heat Pipe Zone Heater  

E-Print Network (OSTI)

A gas-fired vented zone heater has recently been developed by the Altar Corporation for Colorado State University (CSU) under a Gas Research Institute (GRI) contract. The unit war developed for auxiliary heating applications in passive solar buildings. An early prototype was tested at Altas and operated as expected. The final model was shipped to CSU in December 1983 for testing in the REPEAT Facility at CSU. A heat pipe extends through the wall to the outside of the building. It has a modest water charge which can freeze repeatedly with no damage, since the heat pips is only partially filled. Firing efficiency at 4,000 Btu/b (1.17 kW thermal) is approximately 80%. The unit features a 3 foot by 3 foot radiator mounted inside the room to be heated, and is thermostatically controlled. Ignition is accomplished with an electronic sparker (pilot). The radiator typically operates at 150-180°F (65-82°C), and has been operated at between 2,000 and 5,000 Btu/h (0.6-1.47 kW). Results of testing the vented heat pipe zone heater at CSU arm presented. Also, a method for determining the optimal combination of zone heater, passive solar heating and energy conservation measures has been developed. Nomographs have been developed that may be used by a building designer to determine the optimal combination of zone heater size, passive solar system size, and energy conservation measures for given types of passive solar heating systems in selected locations. A representative nomograph is presented along with a design example.

Winn, C. B.; Burns, P.; Guire, J.

1984-01-01T23:59:59.000Z

20

Economics of residential gas furnaces and water heaters in United States new construction market  

E-Print Network (OSTI)

Experiences of residential consumers and utilities. OakStar (2008). Energy Star Residential Water Heaters: Finalefficiency improvements for residential gas furnaces in the

Lekov, Alex B.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Gas-Fired Absorption Heat Pump Water Heater Research Project | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emerging Technologies » Gas-Fired Absorption Heat Pump Water Emerging Technologies » Gas-Fired Absorption Heat Pump Water Heater Research Project Gas-Fired Absorption Heat Pump Water Heater Research Project The U.S. Department of Energy (DOE) is currently conducting research into carbon gas-fired absorption heat pump water heaters. This project will employ innovative techniques to increase water heating energy efficiency over conventional gas storage water heaters by 40%. Project Description This project seeks to develop a natural gas-fired water heater using an absorption heat. The development effort is targeting lithium bromide aqueous solutions as a working fluid in order to avoid the negative implications of using more toxic ammonia. Project Partners Research is being undertaken through a Cooperative Research and Development

22

Radiant zone heated particulate filter  

DOE Patents (OSTI)

A system includes a particulate matter (PM) filter including an upstream end for receiving exhaust gas and a downstream end. A radiant zoned heater includes N zones, where N is an integer greater than one, wherein each of the N zones includes M sub-zones, where M is an integer greater than or equal to one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones, restricts exhaust gas flow in a portion of the PM filter that corresponds to the selected one of the N zones, and deactivates non-selected ones of the N zones.

Gonze, Eugene V [Pinckney, MI

2011-12-27T23:59:59.000Z

23

Radiant Heating  

Energy.gov (U.S. Department of Energy (DOE))

Radiant heating systems involve supplying heat directly to the floor or to panels in the walls or ceiling of a house. The systems depend largely on radiant heat transfer: the delivery of heat...

24

Energy Cost Calculator for Electric and Gas Water Heaters | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electric and Gas Water Heaters Electric and Gas Water Heaters Energy Cost Calculator for Electric and Gas Water Heaters October 8, 2013 - 2:26pm Addthis Vary equipment size, energy cost, hours of operation, and /or efficiency level. INPUT SECTION Input the following data (if any parameter is missing, calculator will set to default value). Defaults Type of Water Heater Electric Gas Electric Average Daily Usage (gallons per day)* gallons 64* Energy Factor† 0.92 (electric) 0.61 (gas) Energy Cost $ / kWh $0.06 per kWh $.60 per therm Quantity of Water Heaters to be Purchased unit(s) 1 unit * See assumptions for various daily water use totals. † The comparison assumes a storage tank water heater as the input type. To allow demand water heaters as the comparison type, users can specify an input EF of up to 0.85; however, 0.66 is currently the best available EF for storage water heaters.

25

Economics of Residential Gas Furnaces and Water Heaters in United...  

NLE Websites -- All DOE Office Websites (Extended Search)

driven by first cost considerations and the availability of power vent and condensing water heaters. Little analysis has been performed to assess the economic impacts of the...

26

Economics of Residential Gas Furnaces and Water Heaters in United States  

NLE Websites -- All DOE Office Websites (Extended Search)

Economics of Residential Gas Furnaces and Water Heaters in United States Economics of Residential Gas Furnaces and Water Heaters in United States New Construction Market Speaker(s): Alex Lekov Gabrielle Wong-Parodi James McMahon Victor Franco Date: May 8, 2009 - 12:00pm Location: 90-3122 In the new single-family home construction market, the choice of what gas furnace and gas water heater combination to install is primarily driven by first cost considerations. In this study, the authors use a life-cycle cost analysis approach that accounts for uncertainty and variability of inputs to assess the economic benefits of installing different gas furnace and water heater combinations. Among other factors, it assesses the economic feasibility of eliminating the traditional metal vents and replacing them with vents made of plastic materials used in condensing and power vent

27

Building America Top Innovations Hall of Fame Profile … Tankless Gas Water Heater Performance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Incorporating tankless water heaters was one Incorporating tankless water heaters was one of many energy-efficiency recommendations Building America's research team IBACOS had for San Antonio builder Imagine Homes. Although tankless gas water heaters should save approximately 33% on hot water heating compared to a conventional storage water heater, actual energy savings vary significantly based on individual draw volume. Above 10 gallons per draw, the efficiency approaches the rated energy factor. The greatest savings occur at a daily use quantity of about 50 gallons. BUILDING AMERICA TOP INNOVATIONS HALL OF FAME PROFILE INNOVATIONS CATEGORY: 1. Advanced Technologies and Practices 1.2 Energy Efficient Components Tankless Gas Water Heater Performance As improved thermal enclosures dramatically reduce heating and cooling loads,

28

Economics of residential gas furnaces and water heaters in US new construction market  

E-Print Network (OSTI)

market research on solar water heaters. National Renew- ablecom- bined space/water heaters, solar water heaters,combined solar space/water heater, electric water heaters

Lekov, Alex B.; Franco, Victor H.; Wong-Parodi, Gabrielle; McMahon, James E.; Chan, Peter

2010-01-01T23:59:59.000Z

29

Study of the Heating Load of a Manufactured Space with a Gas-fired Radiant Heating System  

E-Print Network (OSTI)

A thermal balance mathematics model of a manufactured space with a gas-fired radiant heating system is established to calculate the heating load. Computer programs are used to solve the model. Envelope internal surface temperatures under different outdoor temperatures are obtained, and the heating load of the manufactured space is analyzed. The relationship between the envelope internal surface temperature and the workspace temperature is also analyzed in this paper. CFD simulation software is used to simulate the temperature field and the envelope's internal surface temperature of the manufacture space with hot-air heating system. Comparison and analysis of heating loads are done between the manufactured spaces with convection heating and radiant heating systems.

Zheng, X.; Dong, Z.

2006-01-01T23:59:59.000Z

30

Economics of Condensing Gas Furnaces and Water Heaters Potential in Residential Single Family Homes  

E-Print Network (OSTI)

market research on solar water heaters. National Renewablespace heaters, and solar water heaters, as well as other

Lekov, Alex

2011-01-01T23:59:59.000Z

31

An Evaluation of Low-BTU Gas from Coal as an Alternate Fuel for Process Heaters  

E-Print Network (OSTI)

As the price gap between oil and natural gas and coal continues to widen, Monsanto has carefully searched out and examined opportunities to convert fuel use to coal. Preliminary studies indicate that the low-btu gas produced by fixed-bed, air blown gasifiers could potentially replace the natural gas now used in process heaters. The technology is well established and requires less capital than the higher-btu process heaters. Low-btu gas has sufficient heating value and flame temperature to be acceptable fuel for most process heaters. Economics for gas production appear promising, but somewhat uncertain. Rough evaluations indicate rates of return of as much as 30-40%. However, the economics are very dependent on a number of site- specific considerations including: coal vs. natural gas prices, economic life of the gas-consuming facility, quantity of gas required, need for desulfurization, location of gasifiers in relation to gas users, existence of coal unloading and storage facilities, etc. Two of these factors, the difference between coal and natural gas prices and the project life are difficult to predict. The resulting uncertainty has caused Monsanto to pursue coal gasification for process heaters with cautious optimism, on a site by site basis.

Nebeker, C. J.

1982-01-01T23:59:59.000Z

32

Economics of residential gas furnaces and water heaters in United States new construction market  

E-Print Network (OSTI)

market research on solar water heaters. National Renewabletankless combined space/water heaterds, solar water heaters,combined solar space/water heater, electric water heaters

Lekov, Alex B.

2010-01-01T23:59:59.000Z

33

Economics of residential gas furnaces and water heaters in United States new construction market  

SciTech Connect

New single-family home construction represents a significant and important market for the introduction of energy-efficient gas-fired space heating and water-heating equipment. In the new construction market, the choice of furnace and water-heater type is primarily driven by first cost considerations and the availability of power vent and condensing water heaters. Few analysis have been performed to assess the economic impacts of the different combinations of space and water-heating equipment. Thus, equipment is often installed without taking into consideration the potential economic and energy savings of installing space and water-heating equipment combinations. In this study, we use a life-cycle cost analysis that accounts for uncertainty and variability of the analysis inputs to assess the economic benefits of gas furnace and water-heater design combinations. This study accounts not only for the equipment cost but also for the cost of installing, maintaining, repairing, and operating the equipment over its lifetime. Overall, this study, which is focused on US single-family new construction households that install gas furnaces and storage water heaters, finds that installing a condensing or power-vent water heater together with condensing furnace is the most cost-effective option for the majority of these houses. Furthermore, the findings suggest that the new construction residential market could be a target market for the large-scale introduction of a combination of condensing or power-vent water heaters with condensing furnaces.

Lekov, Alex B.; Franco, Victor H.; Wong-Parodi, Gabrielle; McMahon, James E.; Chan, Peter

2009-05-06T23:59:59.000Z

34

A Simple Method to Continuous Measurement of Energy Consumption of Tank Less Gas Water Heaters for Commercial Buildings  

E-Print Network (OSTI)

energy consumptions of hot water supply in restaurants or residential houses are large amount, guidelines for optimal design are not presented. measurements of energy consumption of tank less gas water heaters very difficult unless gas flow meters were installed. however a gas flow meters is hardly installed for individual heater. in this study, a simple method to estimate gas consumption of such appliances form temperature of exhaust gas and electric current was presented. experiments of japanese major hot water gas heaters were conducted change under conditions of various water flow rate at constant output temperature. the empirical equations, which related gas consumption to exhaust gas temperature and operative current, were obtained for each type of water heaters, each manufacturer and overall heaters. verification of the method was conducted at a commercial building. some thresholds to decide status of operation, such as anti-freeze operation, were set, and sufficient accuracy of around 10 % error was achieved.

Yamaha, M.; Fujita, M.; Miyoshi, T.

2006-01-01T23:59:59.000Z

35

High-pressure ceramic air heater for indirectly fired gas turbine applications  

SciTech Connect

The Externally-Fired Combined Cycle (EFCC) offers a method for operating high-efficiency gas and steam turbine combined cycles on coal. In the EFCC, an air heater replaces the gas turbine combustor so that the turbine can be indirectly fired. Ceramic materials are required for the heat exchange surfaces to accommodate the operating temperatures of modern gas turbines. The ceramic air heater or heat exchanger is the focus of this program, and the two primary objectives are (1) to demonstrate that a ceramic air heater can be reliably pressurized to a level of 225 psia (1.5 MPa); and (2) to show that the air heater can withstand exposure to the products of coal combustion at elevated temperatures. By replacing the gas turbine combustor with a ceramic air heater, the cycle can use coal or other ash-bearing fuels. Numerous programs have attempted to fuel high efficiency gas turbines directly with coal, often resulting in significant ash deposition upon turbine components and corrosion or erosion of turbine blades. This report will show that a ceramic air heater is significantly less susceptible to ash deposition or corrosion than a gas turbine when protected by rudimentary methods of gas-stream clean-up. A 25 [times] 10[sup 6] Btu/hr (7 MW) test facility is under construction in Kennebunk, Maine. It is anticipated that this proof of concept program will lead to commercialization of the EFCC by electric utility and industrial organizations. Applications are being pursued for power plants ranging from 10 to 100 megawatts.

LaHaye, P.G.; Briggs, G.F.; Vandervort, C.L.; Seger, J.L.

1992-01-01T23:59:59.000Z

36

High-pressure ceramic air heater for indirectly fired gas turbine applications  

SciTech Connect

The Externally-Fired Combined Cycle (EFCC) offers a method for operating high-efficiency gas and steam turbine combined cycles on coal. In the EFCC, an air heater replaces the gas turbine combustor so that the turbine can be indirectly fired. Ceramic materials are required for the heat exchange surfaces to accommodate the operating temperatures of modern gas turbines. The ceramic air heater or heat exchanger is the focus of this program, and the two primary objectives are (1) to demonstrate that a ceramic air heater can be reliably pressurized to a level of 225 psia (1.5 MPa); and (2) to show that the air heater can withstand exposure to the products of coal combustion at elevated temperatures. By replacing the gas turbine combustor with a ceramic air heater, the cycle can use coal or other ash-bearing fuels. Numerous programs have attempted to fuel high efficiency gas turbines directly with coal, often resulting in significant ash deposition upon turbine components and corrosion or erosion of turbine blades. This report will show that a ceramic air heater is significantly less susceptible to ash deposition or corrosion than a gas turbine when protected by rudimentary methods of gas-stream clean-up. A 25 {times} 10{sup 6} Btu/hr (7 MW) test facility is under construction in Kennebunk, Maine. It is anticipated that this proof of concept program will lead to commercialization of the EFCC by electric utility and industrial organizations. Applications are being pursued for power plants ranging from 10 to 100 megawatts.

LaHaye, P.G.; Briggs, G.F.; Vandervort, C.L.; Seger, J.L.

1992-12-01T23:59:59.000Z

37

FEMP Designated Product Assessment for Commercial Gas Water Heaters  

E-Print Network (OSTI)

calculated at a federal natural gas price of $.90 per thermaverage commercial price of natural gas using a discount

Lutz, Jim

2012-01-01T23:59:59.000Z

38

Preliminary Modeling, Testing, and Analysis of a Gas Tankless Water Heater: Preprint  

DOE Green Energy (OSTI)

Today's gas tankless water heaters offer significant energy savings over conventional gas storage tank water heaters, but savings depends on the draw pattern. A one-node model incorporating heat exchanger mass is used to address this and other issues. Key model parameters are determined from least-squares regression on short-term data, including burner efficiency, thermal capacitance, and thermal loss coefficient. The calibrated model agrees with data to ~5% on Qgas, with temperature RMS deviation of ~4..deg..C. Efficiency with a standard realistic draw is 71%, compared to 81% predicted from standard energy-factors. Adding a small tank controlled by the tankless heater solves issues of oscillations with solar pre-heat, low-flow and hot-water-delay issues. Future work includes model refinements and developing optimal data protocols for model parameter extraction.

Burch, J.; Hoeschele, M.; Springer, D.; Rudd, A.

2008-05-01T23:59:59.000Z

39

Radiant Solar | Open Energy Information  

Open Energy Info (EERE)

Radiant Solar Radiant Solar Jump to: navigation, search Name Radiant Solar Place Secunderabad, Andhra Pradesh, India Zip 500009 Sector Solar Product Solar products company focused on lanterns, lighting systems and water heaters. Coordinates 17.46071°, 78.49298° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":17.46071,"lon":78.49298,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

40

Gas-fired chiller-heaters as a central plant alternative for small office buildings  

SciTech Connect

Gas absorption chillers-heaters have been applied successfully in large projects where use of multiple chillers is feasible. Large facilities typically have a substantial base cooling load. If the base load is greater than 30% of the minimum capacity of the smallest chiller, chiller-heaters alone can be used as the building central plant. However, this study shows that a small office building presents part-load design difficulties that tend to favor the use of other technologies. The engineer can overcome these application problems by a variety of means, as has been illustrated. Manufacturers, too, are addressing the problems associated with low-load operation of direct-fired chiller heaters. A new generation of chiller-heaters that can unload down to 10% of design load will soon be available. If these new machines are capital-cost-competitive and perform up to expectations, the routine application of chiller-heaters in small commercial buildings may be just around the corner.

Thies, R.M. [JDB Engineering, Inc., York, PA (United States); Bahnfleth, W. [Pennsylvania State Univ., University Park, PA (United States). Dept. of Architectural Engineering

1998-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

2.01 GAS-FIRED UNIT HEATERS  

E-Print Network (OSTI)

a. Requirement for gas fired equipment is limited to structures which are constructed outside the practical limits of the campus central steam distribution system and have access to natural gas from Public Service Company utility distribution system.

Section Basic Mechanical Requirements; A. Design Requirements; A. Manufacturers

2011-01-01T23:59:59.000Z

42

FEMP Designated Product Assessment for Commercial Gas Water Heaters  

E-Print Network (OSTI)

FEMP Designated Product Assessment for Commercial Gas Waterrequirement for FEMP-designated products is generally set at

Lutz, Jim

2012-01-01T23:59:59.000Z

43

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

gas water heaters; and pressure loss calculations for residentialgas water heaters; and pressure loss calculations for residential

Lutz, Jim

2012-01-01T23:59:59.000Z

44

FEMP Designated Product Assessment for Commercial Gas Water Heaters  

E-Print Network (OSTI)

boilers is 80%. The maximum standby loss is specified usingrate. 8 There is no maximum standby loss specified for gas-of hot water use, standby losses are not a significant part

Lutz, Jim

2012-01-01T23:59:59.000Z

45

High Efficiency, Ultra-Low Emission, Integrated Process Heater System  

Science Conference Proceedings (OSTI)

The team of TIAX LLC, ExxonMobil Research and Engineering Company, and Callidus Technologies, LLC conducted a six-year program to develop an ultra-low emission process heater burner and an advanced high efficiency heater design. This project addresses the critical need of process heater operators for reliable, economical emission reduction technologies to comply with stringent emission regulations, and for heater design alternatives that reduce process heater energy requirements without significant cost increase. The key project targets were NOx emissions of 10 ppm (@ 3% O2), and a heater thermal efficiency of 95 percent. The ultra low NOx burner was developed through a series of pilot-scale and field tests combined with computational fluid dynamic modeling to arrive at simultaneous low emissions and suitable flame shape and stability. Pilot scale tests were run at TIAX, at the 2 MMBtu/hr scale, and at Callidus at 8 MMBtu/hr. The full scale burner was installed on a 14 burner atmospheric pipestill furnace at an ExxonMobil refinery. A variety of burner configurations, gas tips and flame stabilizers were tested to determine the lowest emissions with acceptable flame shape and stability. The resulting NOx emissions were 22 ppm on average. Starting in 2001, Callidus commercialized the original ultra low NOx burner and made subsequent design improvements in a series of commercial burners evolving from the original concept and/or development. Emissions in the field with the ultra low-NOx burner over a broad spectrum of heater applications have varied from 5 ppm to 30 ppm depending on heater geometry, heater service, fuel and firing capacity. To date, 1550 of the original burners, and 2500 of subsequent generation burners have been sold by Callidus. The advanced heater design was developed by parametric evaluations of a variety of furnace and combustion air preheater configurations and technologies for enhancing convective and radiative heat transfer. The design evolution relied heavily on computational fluid dynamic predictions of design alternatives. The final design features modular separate radiant cells, each with one and two-side fired vertical tubes. The convection section configuration is vertical tube banks enclosed in the radiant channels. Commercial modular plate air preheaters are used. The predicted performance for the integrated advanced heater and Callidus burner is 95 percent efficiency with 9 ppm NOx emissions firing natural gas, and 12 ppm firing refinery gas. The total erected cost is less than a conventional heater with combustion air preheat.

Mason, Howard; Boral, Anindya; Chhotray, San; Martin, Matthew

2006-06-19T23:59:59.000Z

46

Economics of Condensing Gas Furnaces and Water Heaters Potential in Residential Single Family Homes  

SciTech Connect

Residential space and water heating accounts for over 90percent of total residential primary gas consumption in the United States. Condensing space and water heating equipment are 10-30percent more energy-efficient than conventional space and water heating. Currently, condensing gas furnaces represent 40 percent of shipments and are common in the Northern U.S. market. Meanwhile, manufacturers are planning to develop condensing gas storage water heaters to qualify for Energy Star? certification. Consumers, installers, and builders who make decisions about installing space and water heating equipment generally do not perform an analysis to assess the economic impacts of different combinations and efficiencies of space and water heating equipment. Thus, equipment is often installed without taking into consideration the potential life-cycle economic and energy savings of installing space and water heating equipment combinations. Drawing on previous and current analysis conducted for the United States Department of Energy rulemaking on amended standards for furnaces and water heaters, this paper evaluates the extent to which condensing equipment can provide life-cycle cost-effectiveness in a representative sample of single family American homes. The economic analyses indicate that significant energy savings and consumer benefits may result from large-scale introduction of condensing water heaters combined with condensing furnaces in U.S. residential single-family housing, particularly in the Northern region. The analyses also shows that important benefits may be overlooked when policy analysts evaluate the impact of space and water heating equipment separately.

Lekov, Alex; Franco, Victor; Meyers, Steve

2010-05-14T23:59:59.000Z

47

Metal spray apparatus with a U-shaped electric inlet gas heater and a one-piece electric heater surrounding a nozzle  

SciTech Connect

An electrically heated metal spray apparatus is provided with a supersonic nozzle. Molten metal is injected into a gas stream flowing through the nozzle under pressure. By varying the pressure of the injected metal, the droplet can be made in various selected sizes with each selected size having a high degree of size uniformity. A unique one piece graphite heater provides easily controlled uniformity of temperature in the nozzle and an attached tundish which holds the pressurized molten metal. A unique U-shaped gas heater provides extremely hot inlet gas temperatures to the nozzle. A particularly useful application of the spray apparatus is coating of threads of a fastener with a shape memory alloy. This permits a fastener to be easily inserted and removed but provides for a secure locking of the fastener in high temperature environments.

Glovan, Ronald J. (Butte, MT); Tierney, John C. (Butte, MT); McLean, Leroy L. (Butte, MT); Johnson, Lawrence L. (Butte, MT); Verbael, David J. (Butte, MT)

1995-01-01T23:59:59.000Z

48

Metal spray apparatus with a U-shaped electric inlet gas heater and a one-piece electric heater surrounding a nozzle  

DOE Patents (OSTI)

An electrically heated metal spray apparatus is provided with a supersonic nozzle. Molten metal is injected into a gas stream flowing through the nozzle under pressure. By varying the pressure of the injected metal, the droplet can be made in various selected sizes with each selected size having a high degree of size uniformity. A unique one piece graphite heater provides easily controlled uniformity of temperature in the nozzle and an attached tundish which holds the pressurized molten metal. A unique U-shaped gas heater provides extremely hot inlet gas temperatures to the nozzle. A particularly useful application of the spray apparatus is coating of threads of a fastener with a shape memory alloy. This permits a fastener to be easily inserted and removed but provides for a secure locking of the fastener in high temperature environments. 12 figs.

Glovan, R.J.; Tierney, J.C.; McLean, L.L.; Johnson, L.L.; Verbael, D.J.

1995-10-17T23:59:59.000Z

49

Dampers for Natural Draft Heaters: Technical Report  

E-Print Network (OSTI)

vented natural-draft gas-fired storage water heater. Thevented natural?draft gas?fired storage water heater. Thevented natural?draft gas?fired storage water heater. The

Lutz, James D.

2009-01-01T23:59:59.000Z

50

Development and Validation of a Gas-Fired Residential Heat Pump Water Heater - Final Report  

SciTech Connect

For gas-fired residential water heating, the U.S. and Canada is predominantly supplied by minimum efficiency storage water heaters with Energy Factors (EF) in the range of 0.59 to 0.62. Higher efficiency and higher cost ($700 - $2,000) options serve about 15% of the market, but still have EFs below 1.0, ranging from 0.65 to 0.95. To develop a new class of water heating products that exceeds the traditional limit of thermal efficiency, the project team designed and demonstrated a packaged water heater driven by a gas-fired ammonia-water absorption heat pump. This gas-fired heat pump water heater can achieve EFs of 1.3 or higher, at a consumer cost of $2,000 or less. Led by Stone Mountain Technologies Inc. (SMTI), with support from A.O. Smith, the Gas Technology Institute (GTI), and Georgia Tech, the cross-functional team completed research and development tasks including cycle modeling, breadboard evaluation of two cycles and two heat exchanger classes, heat pump/storage tank integration, compact solution pump development, combustion system specification, and evaluation of packaged prototype GHPWHs. The heat pump system extracts low grade heat from the ambient air and produces high grade heat suitable for heating water in a storage tank for domestic use. Product features that include conventional installation practices, standard footprint and reasonable economic payback, position the technology to gain significant market penetration, resulting in a large reduction of energy use and greenhouse gas emissions from domestic hot water production.

Michael Garrabrant; Roger Stout; Paul Glanville; Janice Fitzgerald; Chris Keinath

2013-01-21T23:59:59.000Z

51

Energy Basics: Conventional Storage Water Heaters  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

heater can range from 20 to hundreds of gallons. Conventional storage water heater fuel sources include natural gas, propane, fuel oil, and electricity. Natural gas and...

52

High-pressure coal-fired ceramic air heater for gas turbine applications. Technical quarterly progress report, May 1994--July 1994  

SciTech Connect

Progress is reported on the development of a coal-fired ceramic air heater for gas turbine applications. This report describes component development.

1996-02-01T23:59:59.000Z

53

Solar pool heater  

SciTech Connect

A solar pool heater is defined by a submersible tubular ring attached to the perimeter of a transparent or translucent sheet. Floatation of the heater is obtained through an air bubble captured by the sheet and maintained by the ring. The ring is perforated to permit the entry of water within the ring to induce partial submersion and thereby establish a peripheral seal about the captured air bubble. The submersed ring also prevents overlapping of adjacent heaters and reduces the likelihood of the heaters being blown off the pool by wind. By developing the sheet from material transparent to at least a spectrum of the solar rays, the air space intermediate the sheet and the underlying water surface will provide a ''greenhouse'' effect to heat the water through direct impingement by the received radiant energy; additionally, radiation of heat from the water will be reduced by the sheet, whereby, the heater not only collects but retains the impinged radiant energy.

Acker, L.C.

1980-09-16T23:59:59.000Z

54

Impact of Pilot Light Modeling on the Predicted Annual Performance of Residential Gas Water Heaters: Preprint  

SciTech Connect

Modeling residential water heaters with dynamic simulation models can provide accurate estimates of their annual energy consumption, if the units? characteristics and use conditions are known. Most gas storage water heaters (GSWHs) include a standing pilot light. It is generally assumed that the pilot light energy will help make up standby losses and have no impact on the predicted annual energy consumption. However, that is not always the case. The gas input rate and conversion efficiency of a pilot light for a GSWH were determined from laboratory data. The data were used in simulations of a typical GSWH with and without a pilot light, for two cases: 1) the GSWH is used alone; and 2) the GSWH is the second tank in a solar water heating (SWH) system. The sensitivity of wasted pilot light energy to annual hot water use, climate, and installation location was examined. The GSWH used alone in unconditioned space in a hot climate had a slight increase in energy consumption. The GSWH with a pilot light used as a backup to an SWH used up to 80% more auxiliary energy than one without in hot, sunny locations, from increased tank losses.

Maguire, J.; Burch, J.

2013-08-01T23:59:59.000Z

55

Convective heater  

DOE Patents (OSTI)

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation. 14 figs.

Thorogood, R.M.

1983-12-27T23:59:59.000Z

56

Convective heater  

DOE Patents (OSTI)

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

Thorogood, Robert M. (Macungie, PA)

1986-01-01T23:59:59.000Z

57

Convective heater  

DOE Patents (OSTI)

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

Thorogood, Robert M. (Macungie, PA)

1983-01-01T23:59:59.000Z

58

Economics of residential gas furnaces and water heaters in United States new construction market  

E-Print Network (OSTI)

D. Winiarski. (1999). WHAM: Simplified tool for calculatingDepartment of Energy 2009b). WHAM yields total water heaterWater Heater Analysis Model (WHAM) method (Lutz et al. 1999)

Lekov, Alex B.

2010-01-01T23:59:59.000Z

59

Economics of residential gas furnaces and water heaters in US new construction market  

E-Print Network (OSTI)

Winiarski, D. (1999). WHAM: Simplified tool for calculatingDepartment of Energy 2009b). WHAM yields total water-heaterWater Heater Analysis Model (WHAM) method (Lutz et al. 1999)

Lekov, Alex B.; Franco, Victor H.; Wong-Parodi, Gabrielle; McMahon, James E.; Chan, Peter

2010-01-01T23:59:59.000Z

60

Economics of residential gas furnaces and water heaters in United States new construction market  

E-Print Network (OSTI)

Refrigeration Institute 2008a). The efficiency of water heaters, depending on the rated volume and other design

Lekov, Alex B.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Economics of residential gas furnaces and water heaters in US new construction market  

E-Print Network (OSTI)

Refrigeration Institute 2008a). The efficiency of water heaters, depending on the rated volume and other design

Lekov, Alex B.; Franco, Victor H.; Wong-Parodi, Gabrielle; McMahon, James E.; Chan, Peter

2010-01-01T23:59:59.000Z

62

High pressure ceramic air heater for indirectly fired gas turbine applications  

SciTech Connect

The EFCC cycle is conceptually simple. Air enters the compressor where it is pressurized and becomes the tube-side flow of the ceramic air heater. Heat transferred from the hot combustion gases flowing through the shell-side raises the air temperature to the desired turbine inlet temperature. Internally insulated high pressure piping returns the heated compressor air to the turbine, where it is expanded providing power to drive the electric generator and gas turbine compressor. Exhaust air from the turbine is used as the combustion air for the coal combustor. The EFCC cycle burns pulverized coal in an atmospheric combustion chamber similar to the combustion system in a conventional steam generator. The combustion gas exits the combustor and enters a slag screen, or impact separator, where the larger ash particles are collected to prevent fouling of the heat exchanger. After the slag screen, the combustion gas enters the shell-side of the CerHX where its thermal energy is transferred to the tube side air flow. Shell-side exit temperatures are sufficiently high to provide thermal energy for the bottoming Rankine Cycle through a heat recovery steam generator. Exhaust gas exiting the steam generator passes through a flue gas desulfurization system and a particulate removal system.

LaHaye, P.G.; Briggs, G.F.; Orozxo, N.J.; Seger, J.L.

1993-11-01T23:59:59.000Z

63

Water Heater Safety FAQs  

NLE Websites -- All DOE Office Websites (Extended Search)

from 30 gallons to 80 gallons in a variety of fuel sources (gas, electric, liquid propane). We also offer a wide selection of Rheem gas and electric tankless water heaters....

64

Economics of Condensing Gas Furnaces and Water Heaters Potential in Residential Single Family Homes  

E-Print Network (OSTI)

seds.html. USDOE. 2009. Residential Energy ConsumptionUSEPA) 2008. Energy Star Residential Water Heaters: FinalExperiences of residential consumers and utilities. Oak

Lekov, Alex

2011-01-01T23:59:59.000Z

65

Absorption Heat Pump Water Heater  

NLE Websites -- All DOE Office Websites (Extended Search)

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

66

Absorption Heat Pump Water Heater  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

67

Energy Basics: Radiant Heating  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

very low heat capacity and have the quickest response time of any heating technology. More Information Visit the Energy Saver website for more information about radiant heating...

68

Energy Basics: Radiant Heating  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

low heat capacity and have the quickest response time of any heating technology. More Information Visit the Energy Saver website for more information about radiant heating in homes...

69

Water heater heat reclaimer  

SciTech Connect

This invention relates to the conservation of energy in a domestic gas water heater by utilizing the hot exhaust gases in a gas water heater for the preheating of the incoming unheated water into the water heater. The exhaust gases from a domestic gas water heater carry wasted heat and the present invention provides a mean to reclaim part of the wasted heat for the preheating of the incoming unheated water during hot water usage periods. During non hot water usage periods the heat in the exhaust gases is not reclaimed to prevent overheating of the water and also to prevent the formation of water deposit in the preheating assembly or heat reclaimer. During the non hot water usage periods the heat produced in the water heater is normally needed only to maintain the desired water temperature of the stored water in the water tank of the water heater. Due to the rapid heating or recovery rate, the present invention enables the use of a smaller water heater. The use of a smaller water heater reduces the normal heat loss from the stored hot water thereby further reduces energy consumption.

Wie, C.T.

1983-08-09T23:59:59.000Z

70

Preliminary Modeling, Testing and Analysis of a Gas Tankless Water Heater  

SciTech Connect

Tankless water heaters offer significant energy savings over conventional storage-tank water heaters, because thermal losses to the environment are much less. Although standard test results are available to compare tankless heaters with storage tank heaters, actual savings depend on the draw details because energy to heat up the internal mass depends on the time since the last draw. To allow accurate efficiency estimates under any assumed draw pattern, a one-node model with heat exchanger mass is posed here. Key model parameters were determined from test data. Burner efficiency showed inconsistency between the two data sets analyzed. Model calculations show that efficiency with a realistic draw pattern is {approx}8% lower than that resulting from using only large {approx}40 liter draws, as specified in standard water-heater tests. The model is also used to indicate that adding a small tank controlled by the tankless heater ameliorates unacceptable oscillations that tankless with feedback control can experience with pre-heated water too hot for the minimum burner setting. The added tank also eliminates problematic low-flow cut-out and hot-water-delay, but it will slightly decrease efficiency. Future work includes model refinements and developing optimal protocols for parameter extraction.

Burch, J.; Thornton, J.; Hoeschele, M.; Springer, D.; Rudd, A.

2008-01-01T23:59:59.000Z

71

NW Natural (Gas) - Business Energy Efficiency Rebate Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NW Natural (Gas) - Business Energy Efficiency Rebate Program NW Natural (Gas) - Business Energy Efficiency Rebate Program NW Natural (Gas) - Business Energy Efficiency Rebate Program < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Appliances & Electronics Other Manufacturing Water Heating Maximum Rebate Custom: $1/annual therm saved Program Info Funding Source Energy Trust of Oregon State District of Columbia Program Type Utility Rebate Program Rebate Amount HVAC Unit Heater: $1.50/kBtu Furnace: $3/kBtu/hr Radiant Heating (Non-Modulating): $6.50/kBtu/hr Radiant Heating (Modulating): $10/kBtu/hr Tank Water Heater: 2.50/kBtu/hr Tankless/Instantaneous Water Heater: $2.00/kBtu/hr

72

Radiant Heating | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiant Heating Radiant Heating Radiant Heating June 24, 2012 - 5:52pm Addthis In-wall radiant heating in a house under construction near Denver. | Photo courtesy of Warren Gretz, NREL. In-wall radiant heating in a house under construction near Denver. | Photo courtesy of Warren Gretz, NREL. Radiant heating systems supply heat directly to the floor or to panels in the wall or ceiling of a house. The systems depend largely on radiant heat transfer -- the delivery of heat directly from the hot surface to the people and objects in the room via infrared radiation. Radiant heating is the effect you feel when you can feel the warmth of a hot stovetop element from across the room. When radiant heating is located in the floor, it is often called radiant floor heating or simply floor heating.

73

Radiant Heating | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiant Heating Radiant Heating Radiant Heating June 24, 2012 - 5:52pm Addthis In-wall radiant heating in a house under construction near Denver. | Photo courtesy of Warren Gretz, NREL. In-wall radiant heating in a house under construction near Denver. | Photo courtesy of Warren Gretz, NREL. Radiant heating systems supply heat directly to the floor or to panels in the wall or ceiling of a house. The systems depend largely on radiant heat transfer -- the delivery of heat directly from the hot surface to the people and objects in the room via infrared radiation. Radiant heating is the effect you feel when you can feel the warmth of a hot stovetop element from across the room. When radiant heating is located in the floor, it is often called radiant floor heating or simply floor heating.

74

Performance and economic evaluation of the seahorse natural gas hot water heater conversion at Fort Stewart. Final report  

SciTech Connect

The Federal government is the largest single energy consumer in the United States with consumption of nearly 1.5 quads/year of energy (10{sup 15} quad = 1015 Btu) and cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the Federal sector. One such effort, the New Technology Demonstration Program (NTDP) seeks to evaluate new energy -- saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate in the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studied under that program. This report provides the results of a field evaluation that PNL conducted for DOE/FEMP with funding support from the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of 4 candidate energy-saving technology-a water heater conversion system to convert electrically powered water heaters to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.

Winiarski, D.W.

1995-12-01T23:59:59.000Z

75

Radiant Barriers | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiant Barriers Radiant Barriers Radiant Barriers May 30, 2012 - 2:07pm Addthis What does this mean for me? Properly installed radiant barriers can reduce your cooling costs. Radiant barriers are easiest to install in new construction, but can be installed in your existing house, especially if it has an open attic. How does it work? Radiant barriers work by reflecting radiant heat away from living spaces. Radiant barriers are installed in homes -- usually in attics -- primarily to reduce summer heat gain and reduce cooling costs. The barriers consist of a highly reflective material that reflects radiant heat rather than absorbing it. They don't, however, reduce heat conduction like thermal insulation materials. How They Work Heat travels from a warm area to a cool area by a combination of

76

Subterrene electrical heater design and morphology  

SciTech Connect

The design, construction, and testing of a variety of electrical heaters for small-diameter Subterrene penetrators has been pursued. The incompatibility of refractory materials at the required operating temperatures of ~2000 deg K and the large heat-flux requirements posed the most difflcult design problems. Heat fluxes of up to 2.0 MW/m/sup 2/ were obtained from pyrolytic-graphite radiant heattransfer elements and were as high as 2.5 MW/m/sup 2/ when this type of heater was combined with a lithium heat-pipe assembly. Penetrators using radiant heaters produced both vertical and horizontal holes of 50 mm dia up to lengths of 25 m, whereas holes of up to 64 mm dia and 0.5 m long were produced in basalt and other rock samples in the laboratory. (auth)

Armstrong, P.E.

1974-02-01T23:59:59.000Z

77

Solar Water Heater Roadmap Leads Path to Market Expansion (Fact...  

NLE Websites -- All DOE Office Websites (Extended Search)

Innovative strategy to reduce installed cost of solar water heater systems can rival conventional natural gas water heaters in the marketplace. Researchers in the Residential...

78

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

E-Print Network (OSTI)

Study on Eco-Design of Water Heaters, Van Holstein en Kemnaand Assessment” in Water Heating Rulemaking TechnicalG. Smith, Tankless Gas Water Heaters: Oregon Market Status,

Lu, Alison

2011-01-01T23:59:59.000Z

79

Reverberatory screen for a radiant burner  

DOE Patents (OSTI)

The present invention relates to porous mat gas fired radiant burner panels utilizing improved reverberatory screens. The purpose of these screens is to boost the overall radiant output of the burner relative to a burner using no screen and the same fuel-air flow rates. In one embodiment, the reverberatory screen is fabricated from ceramic composite material, which can withstand higher operating temperatures than its metallic equivalent. In another embodiment the reverberatory screen is corrugated. The corrugations add stiffness which helps to resist creep and thermally induced distortions due to temperature or thermal expansion coefficient differences. As an added benefit, it has been unexpectedly discovered that the corrugations further increase the radiant efficiency of the burner. In a preferred embodiment, the reverberatory screen is both corrugated and made from ceramic composite material.

Gray, Paul E. (North East, MD)

1999-01-01T23:59:59.000Z

80

Feasibility of Using Measurements of Internal Components of Tankless Water Heaters for Field Monitoring of Energy and Water Use  

E-Print Network (OSTI)

Products: Test Procedures for Water Heaters; Final Rule,"Testing of Tankless Gas Water Heater Performance," DavisInc. , "T-K2 Instantaneous Water Heater Installation Manual

Lutz, Jim

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Where radiant barriers really shine  

Science Conference Proceedings (OSTI)

Manufactures of radiant barrier materials claim their products significantly cut cooling costs by reducing summertime radiant heat gain through attics and ceilings. A new study confirms that radiant barriers can indeed conserve cooling energy. However, the study`s authors found that radiant barriers are much more effective at reducing energy losses from attic air conditioner duct runs than at directly lowering heat transfer through the attic floor into conditioned living space. Furthermore the study demonstrated that radiant barrier savings can be significant even in a new well-weatherized house and that these saving may justify specifying smaller capacity cooling systems. This article discusses the findings of the study.

Engel, R.

1996-07-01T23:59:59.000Z

82

Economics of residential gas furnaces and water heaters in United States new construction market  

E-Print Network (OSTI)

11 shows the monthly natural gas price forecast for 2010 forthe winter when the natural gas prices are lower compared toSep Oct Nov Dec Fig 11 Natural gas price forecast for 2010

Lekov, Alex B.

2010-01-01T23:59:59.000Z

83

Economics of residential gas furnaces and water heaters in United States new construction market  

E-Print Network (OSTI)

11 shows the monthly natural gas price forecast for 2010 forwinter when the natural gas prices are lower compared to theannual prices. Nat. Gas Price (2007$ / MMBtu) New England

Lekov, Alex B.

2010-01-01T23:59:59.000Z

84

Radiant Barriers | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Barriers Barriers Radiant Barriers May 30, 2012 - 2:07pm Addthis What does this mean for me? Properly installed radiant barriers can reduce your cooling costs. Radiant barriers are easiest to install in new construction, but can be installed in your existing house, especially if it has an open attic. How does it work? Radiant barriers work by reflecting radiant heat away from living spaces. Radiant barriers are installed in homes -- usually in attics -- primarily to reduce summer heat gain and reduce cooling costs. The barriers consist of a highly reflective material that reflects radiant heat rather than absorbing it. They don't, however, reduce heat conduction like thermal insulation materials. How They Work Heat travels from a warm area to a cool area by a combination of

85

Performance and economic evaluation of the seahorse natural gas hot water heater conversion at Fort Stewart. Interim report, 1994 Summer  

Science Conference Proceedings (OSTI)

The federal government is the largest single energy consumer in the United States cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate in the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studied under that program. This interim report provides the results of a field evaluation that PNL conducted for DOE/FEMP and the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of a candidate energy-saving technology-a hot water heater conversion system to convert electrically heated hot water tanks to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.

Winiarski, D.W.

1995-01-01T23:59:59.000Z

86

Radiant vessel auxiliary cooling system  

DOE Patents (OSTI)

In a modular liquid-metal pool breeder reactor, a radiant vessel auxiliary cooling system is disclosed for removing the residual heat resulting from the shutdown of a reactor by a completely passive heat transfer system. A shell surrounds the reactor and containment vessel, separated from the containment vessel by an air passage. Natural circulation of air is provided by air vents at the lower and upper ends of the shell. Longitudinal, radial and inwardly extending fins extend from the shell into the air passage. The fins are heated by radiation from the containment vessel and convect the heat to the circulating air. Residual heat from the primary reactor vessel is transmitted from the reactor vessel through an inert gas plenum to a guard or containment vessel designed to contain any leaking coolant. The containment vessel is conventional and is surrounded by the shell.

Germer, John H. (San Jose, CA)

1987-01-01T23:59:59.000Z

87

Radiant Heating | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

heating because it eliminates duct losses. People with allergies often prefer radiant heat because it doesn't distribute allergens like forced air systems can. Hydronic...

88

Heater head for stirling engine  

DOE Patents (OSTI)

A monolithic heater head assembly which augments cast fins with ceramic inserts which narrow the flow of combustion gas and obtains high thermal effectiveness with the assembly including an improved flange design which gives greater durability and reduced conduction loss.

Corey, John A. (R.D. #2, Box 101 E, North Troy, NY 12182)

1985-07-09T23:59:59.000Z

89

Design of a 6- by 6-foot coal-fired heater for a CCGT air heater  

Science Conference Proceedings (OSTI)

Coal-fired heaters for closed-cycle gas turbine have been designed and tested. One of the heater concepts employs the atmospheric pressure fluidized bed coal combustion process. The paper describes a research-oriented bed for the research program. Details are described and discussed of such heaters for cogeneration applications. 2 refs.

Russell, L.H.; Campbell, J. Jr.

1982-01-01T23:59:59.000Z

90

Water heater secondary control device  

SciTech Connect

A secondary control device for gas water heaters is described having a tank, cold water inlet, hot water outlet and a heater thermostat, the control device comprising: valve means for controlling the flow of gas from a source thereof to the heater thermostat, the valve means connected between the gas source and the heater thermostat; means attached to the outside of the cold water inlet for sensing the temperature of water in the cold water inlet and providing an electrical signal representative thereof, the signal generated by the temperature sensing means being connected to the valve means; means for opening the valve means for transmitting the gas to the heater thermostat when the signal is representative of the temperature of the cold water being less than a predetermined temperature; and means for closing the valve means for preventing transmission of the energy to the heater thermostat when the signal is representative of the temperature of the cold water being equal to or greater than the predetermined temperature.

Subherwal, B.R.

1987-08-18T23:59:59.000Z

91

Hydronic Radiant Cooling Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

4 4 Hydronic Radiant Cooling Systems Cooling nonresidential buildings in the U.S. contributes significantly to electrical power consumption and peak power demand. Part of the electrical energy used to cool buildings is drawn by fans transporting cool air through the ducts. The typical thermal cooling peak load component for California office buildings can be divided as follows: 31% for lighting, 13% for people, 14% for air transport, and 6% for equipment (in the graph below, these account for 62.5% of the electrical peak load, labeled "chiller"). Approximately 37% of the electrical peak power is required for air transport, and the remainder is necessary to operate the compressor. DOE-2 simulations for different California climates using the California

92

An energy equivalency analysis of trade-offs between thermal efficiency and standby loss requirements for commercial gas service water heaters  

SciTech Connect

The American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE) Standing Standard Project Committee 90.1 has approved an addendum (90.lb) to ASHRAE/IES Standard 90.1-1989. The addendum specifies an increase in the minimum thermal efficiency requirement (from 77% to 78%), accompanied by an easing of the standby loss requirements, for commercial gas-fired service water heaters. The Pacific Northwest Laboratory performed an energy equivalency analysis to assess the impact of trade-offs between the improved thermal efficiency and the less stringent standby loss requirements. The analysis objective was to estimate whether the energy savings during firing would offset the increased energy losses during standby periods. The primary focus of this report is to summarize the major results of the analysis and provide a recommendation for minimum energy-efficiency commercial gas-fired service water heaters. Limitations to the availability of detailed performance and energy-use data for these commercial water heaters are also pointed out.

Somasundaram, S.; Jarnagin, R.E.; Keller, J.M.; Schliesing, J.S.

1992-06-01T23:59:59.000Z

93

Solar Water Heater Roadmap Leads Path to Market Expansion (Fact Sheet)  

Science Conference Proceedings (OSTI)

Innovative strategy to reduce installed cost of solar water heater systems can rival conventional natural gas water heaters in the marketplace.

Not Available

2012-09-01T23:59:59.000Z

94

Economic Analysis of Solar Water Heaters in GuangZhou  

E-Print Network (OSTI)

As a mature applied technology, the largest obstacle to the promotion of the solar water heater is the high initial investment that makes an impact on consumers' choices. The initial investment and maintenance cost of the solar water heater,gas water heater and electrical water heater in Guangzhou was compared and the Annual Cost Calculation Method (ACCM)was introduced to explain the remarkable economic benefits. The social benefits of the solar water heater were introduced from a scientific view.

Wang, Y.; Zhao, L.

2006-01-01T23:59:59.000Z

95

Radiant Heating Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiant Heating Basics Radiant Heating Basics Radiant Heating Basics August 19, 2013 - 10:33am Addthis Radiant heating systems involve supplying heat directly to the floor or to panels in the walls or ceiling of a house. The systems depend largely on radiant heat transfer: the delivery of heat directly from the hot surface to the people and objects in the room via the radiation of heat, which is also called infrared radiation. Radiant heating is the effect you feel when you can feel the warmth of a hot stovetop element from across the room. When radiant heating is located in the floor, it is often called radiant floor heating or simply floor heating. Despite the name, radiant floor heating systems also depend heavily on convection, the natural circulation of heat within a room, caused by heat rising from the floor. Radiant floor

96

Radiant Heating Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiant Heating Basics Radiant Heating Basics Radiant Heating Basics August 19, 2013 - 10:33am Addthis Radiant heating systems involve supplying heat directly to the floor or to panels in the walls or ceiling of a house. The systems depend largely on radiant heat transfer: the delivery of heat directly from the hot surface to the people and objects in the room via the radiation of heat, which is also called infrared radiation. Radiant heating is the effect you feel when you can feel the warmth of a hot stovetop element from across the room. When radiant heating is located in the floor, it is often called radiant floor heating or simply floor heating. Despite the name, radiant floor heating systems also depend heavily on convection, the natural circulation of heat within a room, caused by heat rising from the floor. Radiant floor

97

ORNL Radiant Barrier - ETSD Division  

NLE Websites -- All DOE Office Websites (Extended Search)

in Zone 2), radiant barriers could reduce your utility bills by as much as 150 per year using average residential electricity prices. If you're able to participate in one of...

98

Radiant energy collector. [Patent application  

DOE Patents (OSTI)

A cylindrical radiant energy collector is provided which includes a reflector spaced apart from an energy absorber. The reflector is of a particular shape which ideally eliminates gap losses.

McIntire, W.R.

1980-02-14T23:59:59.000Z

99

Solar Swimming Pool Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Swimming Pool Heaters Swimming Pool Heaters Solar Swimming Pool Heaters May 29, 2012 - 6:03pm Addthis An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by installing a solar pool heater. They're cost competitive with both gas and heat pump pool heaters, and they have very low annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the following: A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- circulates water through the filter and collector and back to the pool A flow control valve -- automatic or manual device that diverts pool

100

Solar Swimming Pool Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Swimming Pool Heaters Solar Swimming Pool Heaters Solar Swimming Pool Heaters May 29, 2012 - 6:03pm Addthis An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by installing a solar pool heater. They're cost competitive with both gas and heat pump pool heaters, and they have very low annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the following: A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- circulates water through the filter and collector and back to the pool

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Regenerative air heater  

DOE Patents (OSTI)

A gas-cooled steel skirt is used to support a refractory cored brick matrix and dome structure in a high temperature regenerative air heater useful in magnetohydrodynamic power generation. The steel skirt thermally expands to accommodate the thermal expansion of the dome structure despite substantial temperature differential thereby reducing relative movement between the dome bricks. Gas cooling of the steel skirt allows the structure to operate above its normal temperature during clean-out cycles and also allows for the control of the thermal expansion of the steel skirt.

Hasselquist, Paul B. (Maple Grove, MN); Baldner, Richard (Minnetonka, MN)

1982-01-01T23:59:59.000Z

102

Regenerative air heater  

DOE Patents (OSTI)

A gas-cooled steel skirt is used to support a refractory cored brick matrix and dome structure in a high temperature regenerative air heater useful in magnetohydrodynamic power generation. The steel skirt thermally expands to accommodate the thermal expansion of the dome structure despite substantial temperature differential thereby reducing relative movement between the dome bricks. Gas cooling of the steel skirt allows the structure to operate above its normal temperature during clean-out cycles and also allows for the control of the thermal expansion of the steel skirt.

Hasselquist, P.B.; Baldner, R.

1980-11-26T23:59:59.000Z

103

Small Space Heaters  

Energy.gov (U.S. Department of Energy (DOE))

Small space heaters, also called portable heaters, are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. Space heater capacities...

104

Condensing Hybrid Water Heater Monitoring Field Evaluation  

Science Conference Proceedings (OSTI)

This paper summarizes the Mascot home, an abandoned property that was extensively renovated. Several efficiency upgrades were integrated into this home, of particular interest, a unique water heater (a Navien CR240-A). Field monitoring was performed to determine the in-use efficiency of the hybrid condensing water heater. The results were compared to the unit's rated efficiency. This unit is Energy Star qualified and one of the most efficient gas water heaters currently available on the market.

Maguire, J.; Earle, L.; Booten, C.; Hancock, C. E.

2011-10-01T23:59:59.000Z

105

Solar heater  

SciTech Connect

The invention is a solar heater which may function as a humidifier and which has a reflector that is constructed to provide a window, and external thermal insulation. The window has a cover that is positioned to transmit solar radiation to the reflector. The top portion of the reflector has an opening, and a container is removably positioned in the opening. The reflector has a geometry that reflects a high percentage of solar energy to the container, which has a surface with high absorptance. The container has a removable lid for confining heat within the container for certain functions, such as boiling water or drying clothes. When used as a humidifier, the container is filled with water and the lid is removed.

Hill, C.W.

1981-06-23T23:59:59.000Z

106

Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating  

SciTech Connect

Homebuilders are exploring more cost effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads with the following key findings: 1) The tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system. 2) The tankless combo system consistently achieved better daily efficiencies (i.e. 84%-93%) than the storage combo system (i.e. 81%- 91%) when the air handler was sized adequately and adjusted properly to achieve significant condensing operation. When condensing operation was not achieved, both systems performed with lower (i.e. 75%-88%), but similar efficiencies. 3) Air handlers currently packaged with combo systems are not designed to optimize condensing operation. More research is needed to develop air handlers specifically designed for condensing water heaters. 4) System efficiencies greater than 90% were achieved only on days where continual and steady space heating loads were required with significant condensing operation. For days where heating was more intermittent, the system efficiencies fell below 90%.

Kingston, T.; Scott, S.

2013-03-01T23:59:59.000Z

107

Simulated Attic Radiant Barrier Performance  

Science Conference Proceedings (OSTI)

A recent EPRI evaluation determined that attic radiant barriers installed under roof decks are increasingly effective in reducing cooling energy use as insolation increases and ceiling insulation thickness decreases. A savings worksheet included in this report allows rapid estimation of these energy cost impacts.

1991-03-29T23:59:59.000Z

108

Inverse optimal design of the radiant heating in materials processing and manufacturing  

Science Conference Proceedings (OSTI)

Combined convective, conductive, and radiative heat transfer is analyzed during heating of a continuously moving load in the industrial radiant oven. A transient, quasi-three-dimensional model of heat transfer between a continuous load of parts moving inside an oven on a conveyor belt at a constant speed and an array of radiant heaters/burners placed inside the furnace enclosure is developed. The model accounts for radiative exchange between the heaters and the load, the conduction in the load, and convective heat transfer between the moving load and oven environment. The thermal model developed has been used to construct a general framework for an inverse optimal design of an industrial oven as an example. In particular, the procedure based on the Levenberg-Marquardt nonlinear least squares optimization algorithm has been developed to obtain the optimal temperatures of the heaters/burners that need to be specified to achieve a prescribed temperature distribution of the surface of a load. The results of calculations for several sample cases are reported to illustrate the capabilities of the procedure developed for the optimal inverse design of an industrial radiant oven.

Fedorov, A.G.; Lee, K.H.; Viskanta, R. [Purdue Univ., West Lafayette, IN (United States)] [Purdue Univ., West Lafayette, IN (United States)

1998-12-01T23:59:59.000Z

109

Water Heaters | Open Energy Information  

Open Energy Info (EERE)

Heaters Jump to: navigation, search TODO: Add description List of Water Heaters Incentives Retrieved from "http:en.openei.orgwindex.php?titleWaterHeaters&oldid267202...

110

Heater head for Stirling engine  

SciTech Connect

This patent describes a heater head for a Stirling engine comprising: a housing for enclosing the heater head with gas at a substantial elevated pressure; insulator means attached to the housing for insulating the heater head; inlet means attached to a regenerator in the housing for admission of relatively high pressure working fluid from the regenerator of a Stirling engine; a first annular heating wall in the housing attached to the inlet means for heating the working fluid; and, a second annular heating wall in the housing concentric with the first heating wall but of lesser diameters so that an annular space is formed between the first heating wall and the second heating wall for heating working fluid; and a third heating wall in the housing concentric with and smaller in diameter than the second heating wall forming the condensing area of a heat pipe between the second heating wall and the third heating wall.

White, M.A.; Emigh, S.G.

1987-06-09T23:59:59.000Z

111

Radiant Apparatus | Open Energy Information  

Open Energy Info (EERE)

Apparatus Apparatus Jump to: navigation, search Name Radiant Apparatus Place Fairfax, Virginia Zip 22038-3333 Sector Solar Product Radiant Apparatus develops multi-functional, portable solar energy-harnessing systems, as well as potable water systems and emergency shelters. Coordinates 38.841574°, -77.308132° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.841574,"lon":-77.308132,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

112

Radiant Energy | Open Energy Information  

Open Energy Info (EERE)

Energy Energy Jump to: navigation, search Name Radiant Energy Place Pleasanton, California Zip 94566 Sector Geothermal energy, Hydro, Solar Product Radiant is an independent energy producer which develops and owns solar, geothermal, and hydroelectric generating assets. Coordinates 28.967394°, -98.478862° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":28.967394,"lon":-98.478862,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

113

Feedwater Heater Maintenance Guide  

Science Conference Proceedings (OSTI)

This guide provides plant personnel with information on the operation, maintenance, and performance of feedwater heaters. The contents of this guide will assist plant personnel in improving feedwater heater reliability, performance, and maintenance practices.

2002-05-29T23:59:59.000Z

114

Conventional Storage Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

Conventional storage water heaters remain the most popular type of water heating system for homes and buildings.

115

Welding shield for coupling heaters  

DOE Patents (OSTI)

Systems for coupling end portions of two elongated heater portions and methods of using such systems to treat a subsurface formation are described herein. A system may include a holding system configured to hold end portions of the two elongated heater portions so that the end portions are abutted together or located near each other; a shield for enclosing the end portions, and one or more inert gas inlets configured to provide at least one inert gas to flush the system with inert gas during welding of the end portions. The shield may be configured to inhibit oxidation during welding that joins the end portions together. The shield may include a hinged door that, when closed, is configured to at least partially isolate the interior of the shield from the atmosphere. The hinged door, when open, is configured to allow access to the interior of the shield.

Menotti, James Louis (Dickinson, TX)

2010-03-09T23:59:59.000Z

116

Selecting a new water heater  

SciTech Connect

This fact sheet describes the types of water heaters available (storage water heaters, demand water heaters, heat pump water heaters, tankless coil and indirect water heaters, and solar water heaters). The criteria for selection are discussed. These are capacity, efficiency rating, and cost. A resource list is provided for further information.

NONE

1995-03-01T23:59:59.000Z

117

An Overview of the New Residential Water Heater Efficiency Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

An Overview of the New Residential Water Heater Efficiency Standards An Overview of the New Residential Water Heater Efficiency Standards Speaker(s): Alex Lekov Date: April 26, 2010 - 12:00pm Location: 90-3122 DOE issued new standards for residential water heaters last month that will save an estimated 2.6 quads of energy over 30 years. For most product sizes sold, the new standards can be met with modest changes, such as adding more insulation to today's conventional tank-style water heaters. For the most common size electric water heater (50 gallons), the standards will save 4 percent, while for the most common size gas water heater (40 gallons), the new standards will save 3 percent. However, for the biggest products (those with over 55 gallons in storage capacity, which is about 9% and 4% of the electric and gas storage water heater markets, respectively), the new

118

Cascade Natural Gas - Commercial Efficiency Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cascade Natural Gas - Commercial Efficiency Rebate Program Cascade Natural Gas - Commercial Efficiency Rebate Program Cascade Natural Gas - Commercial Efficiency Rebate Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Appliances & Electronics Sealing Your Home Design & Remodeling Windows, Doors, & Skylights Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount HVAC Unit Heater: $1.50-$3 / kBtuh input Warm Air Furnace: $3.00 / kBtuh input Direct Fired Radiant Heating: $6.50 / kBtuh input Boiler: $4.00 / kBtuh input Boiler Vent Damper: $1,000 Boiler Steam Trap: $80 DHW Energy Star Tankless Water Heaters: $60 / gpm Domestic Hot Water Tank: $2.50 / kBtuh input

119

Estimating the Cost and Energy Efficiency of a Solar Water Heater |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR What does this mean for me? Solar water heaters cost more to purchase and install but may save you money in the long run. Estimate the annual operating costs and compare several solar water heaters to determine whether it is worth investing in a more efficient system. Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can

120

Estimating the Cost and Energy Efficiency of a Solar Water Heater |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR What does this mean for me? Solar water heaters cost more to purchase and install but may save you money in the long run. Estimate the annual operating costs and compare several solar water heaters to determine whether it is worth investing in a more efficient system. Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Radiant barrier applications: Symposium and workshop proceedings  

Science Conference Proceedings (OSTI)

Electric utilities and their customers are continually looking for ways to improve the thermal integrity of buildings. Radiant barrier systems can reduce summer air conditioning loads by reducing radiant heat transfer in attics. EPRI conducted two programs to help utilities with radiant barriers. A Symposium and Workshop were conducted in April 1988. The Symposium reviewed the state of the art in radiant barriers. The Workshop brought industry experts together to identify research needs for radiant barriers. The Workshop found that research is needed in six major areas. Listed in order of importance these are: (1) Field and laboratory testing, (2) Materials research, (3) Modeling, (4) Materials standards, (5) Economic issues, and (6) Installation methods. The leading research topics within these six major areas in order of importance include:(1) Modeling to fill voids in existing field data and aid in the development of performance standards, (2) Calculation of energy savings for various configurations, (3) Analysis of existing data to better understand radiant barrier performance, (4) Assessment of the effect of dust accumulation on performance, (5) Development of standard testing procedures, (6) Development of systems standards, (7) Measurement of changes in the emissivity of radiant barrier materials with time, (8) Determination of the possibility of moisture accumulation under horizontal radiant barriers during heating season operation, (9) Ventilation effects, (10) Configuration testing, (11) Costs of new and retrofit applications, and (12) Characterization of side effects. 34 refs., 5 figs.

Isaksen, L.

1989-02-01T23:59:59.000Z

122

Dampers for Natural Draft Heaters: Technical Report  

Science Conference Proceedings (OSTI)

Energy required for water heating accounts for approximately 40percent of national residential natural gas consumption in California. With water heating contributing such a substantial portion of natural gas consumption, it is important to pay attention to water heater efficiencies. This paper reports on an investigation of a patented, buoyancy-operated flue damper. It is an add-on design to a standard atmospherically vented natural-draft gas-fired storage water heater. The flue damper was expected to reduce off-cycle standby losses, which would lead to improvements in the efficiency of the water heater. The test results showed that the Energy Factor of the baseline water heater was 0.576. The recovery efficiency was 0.768. The standby heat loss coefficient was 10.619 (BTU/hr-oF). After the damper was installed, the test results show an Energy Factor for the baseline water heater of 0.605. The recovery efficiency was 0.786. The standby heat loss coefficient was 9.135 (BTU/hr-oF). The recovery efficiency increased 2.3percent and the standby heat loss coefficient decreased 14percent. When the burner was on, the baseline water heater caused 28.0 CFM of air to flow from the room. During standby, the flow was 12.4 CFM. The addition of the damper reduced the flow when the burner was on to 23.5 CFM. During standby, flow with the damper was reduced to 11.1 CFM. The flue damper reduced off-cycle standby losses, and improved the efficiency of the water heater. The flue damper also improved the recovery efficiency of the water heater by restricting on-cycle air flows through the flue.With or without the flue damper, off-cycle air flow upthe stack is nearly half the air flow rate as when the burner is firing.

Lutz, James D.; Biermayer, Peter; King, Derek

2008-10-27T23:59:59.000Z

123

ELDON water heater  

SciTech Connect

Experience with the installation of an ELDON water heater in the TLC Services, Inc. laundry facility is reported. Piping diagram and pictures are included. (MHR)

Wood, H.E.

1980-07-18T23:59:59.000Z

124

Heat Pump Swimming Pool Heaters | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

from the hot gas to the cooler pool water circulating through the heater. The heated water then returns to the pool. The hot gas, as it flows through the condenser coil, returns...

125

Insulation refit kit for domestic water heaters  

SciTech Connect

The development, testing, and marketing of an insulation kit which homeowners could apply to gas or electric hot water heaters in order to conserve energy in water heating are described. The kit, being marketed at $20, should save 450 kWh or 3600 ft/sup 3/ of gas per year. (LCL)

1977-03-23T23:59:59.000Z

126

Heat Pump Swimming Pool Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Swimming Pool Heaters Swimming Pool Heaters Heat Pump Swimming Pool Heaters May 29, 2012 - 1:49pm Addthis How a heat pump works. How a heat pump works. How They Work Heat pumps use electricity to capture heat and move it from one place to another. They don't generate heat. As the pool pump circulates the swimming pool's water, the water drawn from the pool passes through a filter and the heat pump heater. The heat pump heater has a fan that draws in the outside air and directs it over the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside air and becomes a gas. The warm gas in the coil then passes through the compressor. The compressor increases the heat, creating a very hot gas that then passes through the condenser. The condenser transfers the heat from the hot gas to the cooler pool water circulating

127

Pre-heater for water heater  

SciTech Connect

This patent describes an apparatus for pre-heating water prior to the water entering a conventional water heater comprising: heat exchanger means located inside the attic of a residential dwelling for effecting a heat exchange between hot air; vent pipe means connected to the continuous pipe; drain pipe means connected to the continuous pipe; fourth pipe means connected to the drain pipe means; fifth pipe means connected to the junction of the fourth pipe means; and the water heater means connected to the outlet of the heat exchanger means.

Blount, E.R.

1987-06-09T23:59:59.000Z

128

Energy Basics: Small Space Heaters  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

storage, allowing the heater to cycle less and to provide a more constant heat source. More Information Visit the Energy Saver website for more information about portable heaters...

129

Development of a gas backup heater for solar domestic hot-water systems. Final report, April 1978-April 1980  

DOE Green Energy (OSTI)

A comprehensive program was undertaken to develop a unique gas fired backup for solar domestic hot water systems. Detailed computer design tools were written. A series of heat transfer experiments were performed to characterize the performance of individual components. A full scale engineering prototype, including the solar preheat tank and solar heat exchanger, was designed, fabricated and subjected to limited testing. Firing efficiency for the backup system was found to be 81.4% at a firing rate of 50,000 Btu/h. Long term standby losses should be negligible.

Morrison, D.J.; Grunes, H.E.; de Winter, F.; Armstrong, P.R.

1980-06-01T23:59:59.000Z

130

Performance Study of Swimming Pool Heaters  

Science Conference Proceedings (OSTI)

The objective of this report is to perform a controlled laboratory study on the efficiency and emissions of swimming pool heaters based on a limited field investigation into the range of expected variations in operational parameters. Swimming pool heater sales trends have indicated a significant decline in the number of conventional natural gas-fired swimming pool heaters (NGPH). On Long Island the decline has been quite sharp, on the order of 50%, in new installations since 2001. The major portion of the decline has been offset by a significant increase in the sales of electric powered heat pump pool heaters (HPPH) that have been gaining market favor. National Grid contracted with Brookhaven National Laboratory (BNL) to measure performance factors in order to compare the relative energy, environmental and economic consequences of using one technology versus the other. A field study was deemed inappropriate because of the wide range of differences in actual load variations (pool size), geographic orientations, ground plantings and shading variations, number of hours of use, seasonal use variations, occupancy patterns, hour of the day use patterns, temperature selection, etc. A decision was made to perform a controlled laboratory study based on a limited field investigation into the range of expected operational variations in parameters. Critical to this are the frequency of use, temperature selection, and sizing of the heater to the associated pool heating loads. This would be accomplished by installing a limited amount of relatively simple compact field data acquisition units on selected pool installations. This data included gas usage when available and alternately heater power or gas consumption rates were inferred from the manufacturer's specifications when direct metering was not available in the field. Figure 1 illustrates a typical pool heater installation layout.

McDonald, R.J.

2009-01-01T23:59:59.000Z

131

Radiant Barrier Performance during the Heating Season  

E-Print Network (OSTI)

Results of winter experiments conducted in Central Texas are presented. The experiments were side-by-side tests using two identical 144 ft2 houses which responded similarly to weather variations prior to any retrofits. Two radiant barrier orientations were tested, horizontal barrier and barrier against the rafters, in vented and non-vented attics. The results compiled in this paper are for attics with R-19 fiberglass insulation. The data showed that radiant barriers were still effective during the winter season. During a typical day radiant barriers prevented approximately 9-17 percent of the indoor heat from escaping into the attic. No significant difference in moisture accumulation was detected in the attic with the radiant barrier.

Medina, M. A.; O'Neal, D. L.; Turner, W. D.

1992-05-01T23:59:59.000Z

132

Generation of negative ions in the gas phase from a 12CaO{center_dot}7Al{sub 2}O{sub 3} membrane-coated ceramic heater under atmospheric pressure  

Science Conference Proceedings (OSTI)

12CaO{center_dot}7Al{sub 2}O{sub 3} (C12A7) crystal is able to generate strong and high purity oxygen anion (O{sup -}) beam under reduced pressure. However, the emission of O{sup -} or related species under atmospheric pressure has not been evaluated. In this study, the characteristics of negative ion species emissions from the C12A7 membrane-coated ceramic heater under atmospheric pressure were investigated by quadrupole mass spectrometer. Negative ion species were confirmed to be emitted even under atmospheric pressure. It was supposed that the detected negative ion clusters, such as O{sup -}(H{sub 2}O){sub n}, O{sub 2}{sup -}(H{sub 2}O){sub n}, and CO{sub 4}{sup -}(H{sub 2}O){sub n}, were generated by the reaction of negative ions emitted from the heater with impurities in He gas.

Yamamoto, Mitsuo [College of Arts and Sciences, University of Tokyo, Tokyo 153-8902 (Japan); Shima, Akio [Department of Chemical System Engineering, University of Tokyo, Tokyo 113-8656 (Japan); Nishioka, Masateru [Research Center for Compact Chemical Process, National Institute of Advanced Industrial Science and Technology (AIST), Miyagi 983-8551 (Japan); Sadakata, Masayoshi [Department of Environmental Chemical Engineering, Kogakuin University, Tokyo 192-0015 (Japan)

2008-12-15T23:59:59.000Z

133

Prismatic wall heater  

Science Conference Proceedings (OSTI)

A prismatic beam concentrator mounted at the top of two adjacent walls so as to receive a rectangular incipient beam of diffused sunlight and emit a vertical concentrated sheet beam through a cavity between the walls to a mirror which reflects the beam at right angles onto a radiant iron bar at the base of one wall, as a source of supplemental household heat.

Clegg, J. E.

1985-07-09T23:59:59.000Z

134

Fired heater versus CCGT/cogeneration cycle parameters  

Science Conference Proceedings (OSTI)

Initial results are given of a newly designed coal-fired, closed-cycle gas turbine (CCGT) for a cogeneration plant. The coal burning heater is the most costly unit of such a system. The interrelationship between the technical and economic feasibility of the heater and turbine parameters are discussed. 7 refs.

Campbell, J. Jr.; Lee, J.C.

1982-01-01T23:59:59.000Z

135

Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program (Georgia) Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program (Georgia) < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Georgia Program Type Utility Rebate Program Rebate Amount Existing Homes Solar Water Heater: $750 New Homes Solar Water Heater: $1,250 - $1,500 Provider Coweta-Fayette Electric Membership Corporation Coweta-Fayette Electric Membership Corporation (EMC) provides electric and natural gas service to 58,000 customers in Georgia's Coweta, Fayette, Meriwether, Heard, Troop and Fulton counties. Currently, Coweta-Fayette EMC offers rebates on solar water heaters from $750 up to $1,500 as part of the Touchstone Energy Home Program. Solar

136

Performance Testing of Radiant Barriers  

E-Print Network (OSTI)

TVA has conducted a study to determine the effects of radiant barriers (RBI (i.e., material with a low emissivity surface facing an air space), when used with fiberglass, on attic heat transfer during summer and winter. This study employed five small test cells exposed to ambient conditions and having attics with gable and soffit vents. Three different RB configurations were tested and compared to the non-RR configuration. Heat flux transducers determined the heat transfer between the attic and conditioned space. The results showed that all RB con figurations significantly reduced heat gain through the ceiling during the summer. Reductions in heat gain during daylight and peak electric load hours were especially attractive. Roof temperatures for the RB configurations were only slightly higher than for the non-RB case. Heat transfer reductions for the RB configurations in the winter were smaller than those for the summer but were still significant in many, but not all, situations. Savings during night and peak electric load hours were especially attractive.

Hall, J. A.

1986-01-01T23:59:59.000Z

137

Cryostat including heater to heat a target  

DOE Patents (OSTI)

A cryostat is provided which comprises a vacuum vessel; a target disposed within the vacuum vessel; a heat sink disposed within the vacuum vesssel for absorbing heat from the detector; a cooling mechanism for cooling the heat sink; a cryoabsorption mechanism for cryoabsorbing residual gas within the vacuum vessel; and a heater for maintaining the target above a temperature at which the residual gas is cryoabsorbed in the course of cryoabsorption of the residual gas by the cryoabsorption mechanism.

Pehl, Richard H. (Berkeley, CA); Madden, Norman W. (Livermore, CA); Malone, Donald F. (Oakland, CA)

1990-01-01T23:59:59.000Z

138

Cryostat including heater to heat a target  

DOE Patents (OSTI)

A cryostat is provided which comprises a vacuum vessel; a target disposed within the vacuum vessel; a heat sink disposed within the vacuum vessel for absorbing heat from the detector; a cooling mechanism for cooling the heat sink; a cryoabsorption mechanism for cryoabsorbing residual gas within the vacuum vessel; and a heater for maintaining the target above a temperature at which the residual gas is cryoabsorbed in the course of cryoabsorption of the residual gas by the cryoabsorption mechanism. 2 figs.

Pehl, R.H.; Madden, N.W.; Malone, D.F.

1990-09-11T23:59:59.000Z

139

Combustion heater for oil shale  

DOE Patents (OSTI)

A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650 to 700/sup 0/C for use as a process heat source.

Mallon, R.; Walton, O.; Lewis, A.E.; Braun, R.

1983-09-21T23:59:59.000Z

140

Combustion heater for oil shale  

DOE Patents (OSTI)

A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650.degree.-700.degree. C. for use as a process heat source.

Mallon, Richard G. (Livermore, CA); Walton, Otis R. (Livermore, CA); Lewis, Arthur E. (Los Altos, CA); Braun, Robert L. (Livermore, CA)

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Tankless Demand Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as needed and without the use of a storage tank. They...

142

Performance characterization of a hydrogen catalytic heater.  

DOE Green Energy (OSTI)

This report describes the performance of a high efficiency, compact heater that uses the catalytic oxidation of hydrogen to provide heat to the GM Hydrogen Storage Demonstration System. The heater was designed to transfer up to 30 kW of heat from the catalytic reaction to a circulating heat transfer fluid. The fluid then transfers the heat to one or more of the four hydrogen storage modules that make up the Demonstration System to drive off the chemically bound hydrogen. The heater consists of three main parts: (1) the reactor, (2) the gas heat recuperator, and (3) oil and gas flow distribution manifolds. The reactor and recuperator are integrated, compact, finned-plate heat exchangers to maximize heat transfer efficiency and minimize mass and volume. Detailed, three-dimensional, multi-physics computational models were used to design and optimize the system. At full power the heater was able to catalytically combust a 10% hydrogen/air mixture flowing at over 80 cubic feet per minute and transfer 30 kW of heat to a 30 gallon per minute flow of oil over a temperature range from 100 C to 220 C. The total efficiency of the catalytic heater, defined as the heat transferred to the oil divided by the inlet hydrogen chemical energy, was characterized and methods for improvement were investigated.

Johnson, Terry Alan; Kanouff, Michael P.

2010-04-01T23:59:59.000Z

143

The Super-Radiant Mechanism, Doorway States, and Nuclear Reactions  

SciTech Connect

In 1954 the possibility of forming a 'super-radiant' (SR) state in a gas of atoms confined to a volume of a size smaller than the wave length of radiation was suggested by Dicke. The atoms, with two levels, are coupled through their common radiation field. This indirect coupling leads to a redistribution of decay widths among unstable intrinsic states. A strongly decaying SR state is created at the expense of the rest of the states of the system. The connection of this mechanism to the notion of doorway states in low-energy nuclear reactions is discussed and applications to well known nuclear physics phenomena are presented.

Auerbach, Naftali [School of Physics and Astronomy, Tel Aviv University, Tel Aviv, 69978 (Israel)

2010-11-24T23:59:59.000Z

144

Feedwater Heater Technology Symposium  

Science Conference Proceedings (OSTI)

Feedwater heaters and associated systems cause significant loss of availability and heat rate degradation in both nuclear and fossil-fired power plants. One reason for this is that feedwater heater (FWH) deterioration tends to be exponential in nature. While the first plugged FWH tubes have very little impact on unit availability, an increase in the number of plugged tubes raises the velocity in the remaining tubes and results in a greater number of tube leaks. Eventually, retubing, replacement, or bypas...

2004-07-26T23:59:59.000Z

145

Measure Guideline: Transitioning to a Tankless Water Heater  

Science Conference Proceedings (OSTI)

This Measure Guideline provides information to help residential builders and retrofitters with the design, specification, selection, implementation, installation, and maintenance issues of transitioning from tank-type water heaters to tankless water heaters. The report compares the differences between tankless and tank-type water heaters, highlighting the energy savings that can be realized by adopting tankless water heaters over tank-type water heaters. Selection criteria and risks discussed include unit sizing and location, water distribution system, plumbing line length and diameter, water quality, electrical backup, and code issues. Cost and performance data are provided for various types of tankless and tank-type water heaters, both natural gas fired and electric. Also considered are interactions between the tankless water heater and other functional elements of a house, such as cold water supply and low-flow devices. Operating costs and energy use of water distribution systems for single- and two-story houses are provided, along with discussion of the various types of distribution systems that can be used with tankless water heaters. Finally, details to prepare for proper installation of a tankless water heater are described.

Brozyna, K.; Rapport, A.

2012-09-01T23:59:59.000Z

146

Buildings Energy Data Book: 5.4 Water Heaters  

Buildings Energy Data Book (EERE)

4 Water Heater Stock for Commercial Buildings, By Fuel Type Fuel Type Electric 41% Natural Gas 31% Fuel Oil 2% PropaneLPG 3% District Heat 1% No Water Heating 25% Note(s):...

147

Buildings Energy Data Book: 5.4 Water Heaters  

Buildings Energy Data Book (EERE)

1 Water Heater Stock for Residential Buildings, By Fuel Type Electric Natural Gas Fuel Oil PropaneLPG Other 0.2 0.2% Total (1) Note(s): Souce(s): According to RECS, 1.1 million...

148

Gas Water Heater Energy Losses  

E-Print Network (OSTI)

non-firing, non- recovery mode, i.e. , during standby mode.The stack losses while in standby mode account for about 43%can be made by reducing standby heat losses. This paper

Biermayer, Peter

2012-01-01T23:59:59.000Z

149

Gas Water Heater Energy Losses  

E-Print Network (OSTI)

Insul. Thk. (in) 11. Supply Pipe Heat Trap (0,1,-1)* 12.Draw Pipe Heat Trap (0,1,-1)* * 0 = No heat trap 1 = Metallosses through the pipes by improving heat traps and by

Biermayer, Peter

2012-01-01T23:59:59.000Z

150

Combined Systems with Tankless Water Heaters  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Combined Systems with Tankless Water Heaters Combined Systems with Tankless Water Heaters Armin Rudd Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas 2 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas More builder's wanting to use gas-fired tankless water heaters, and with solar pre-heat  Endless hot water  Helps HERS Index  Space saving 2 3 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas Problem with elevated TWH inlet temperature 60 70 80 90 100 110 120 130 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 Maximum Inlet Temperature (F) DHW flow rate (gpm) Maximum TWH inlet temperature to stay below 125 F delivered temperature, with 15 kBtu/h minimum firing rate Typical shower temperature 4 Residential Energy Efficiency Stakeholder Meeting

151

IMPROVEMENTS TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION  

E-Print Network (OSTI)

IMPROVEMENTS TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION PROCEDURE By BEREKET TO THE RADIANT TIME SERIES METHOD COOLING LOAD CALCULATION PROCEDURE Dissertation Approved: Dr. Jeffrey D- Original RTSM.......................................................153 4.4.1 RTSM Peak Design Cooling Load

152

Assessing the Energy Savings of Tankless Water Heater Retrofits in Public Housing  

Science Conference Proceedings (OSTI)

This report describes the methodology, analysis, and findings from a case study of a 110 unit retrofit of gas tankless water heaters in a hot/humid climate in Alachua County, Florida. The housing units had their gas-fired tank type water heaters replaced with gas-fired tankless water heaters as part of a federal program that targeted reduced energy use in public housing.

Ries, R.; Walters, R.; Dwiantoro, D.

2013-01-01T23:59:59.000Z

153

Fired heater for coal liquefaction process  

DOE Patents (OSTI)

A fired heater for a coal liquefaction process is operated under conditions to maximize the slurry slug frequency and thereby improve the heat transfer efficiency. The operating conditions controlled are (1) the pipe diameter and pipe arrangement, (2) the minimum coal/solvent slurry velocity, (3) the maximum gas superficial velocity, and (4) the range of the volumetric flow velocity ratio of gas to coal/solvent slurry.

Ying, David H. S. (Macungie, PA); McDermott, Wayne T. (Allentown, PA); Givens, Edwin N. (Bethlehem, PA)

1985-01-01T23:59:59.000Z

154

Fuel heater thermostat  

Science Conference Proceedings (OSTI)

A thermostat is described for fuel heaters wherein the fuel is heated by engine coolant and the thermostat comprises: a temperature sensing means for sensing the temperature of fuel in the fuel heater, the temperature sensing means in contacting relation with the first end of a coolant flow restricting piston, the piston having a second end in contacting relation with a pressure means wherein the temperature sensing means and the pressure means assert opposing forces against the piston and the piston in response to an increase in force from the temperature sensing means will restrict the flow of coolant through the fuel heater, and the piston further having a bleed port therein to allow coolant to flow to the first and second ends of the piston.

Ray, D.A.

1989-05-09T23:59:59.000Z

155

A model for improvement of water heating heat exchanger designs for residential heat pump water heaters.  

E-Print Network (OSTI)

??Heat pump water heaters are a promising technology to reduce energy use and greenhouse gas emissions. A key component is the water heating heat exchanger.… (more)

Weerawoot, Arunwattana

2010-01-01T23:59:59.000Z

156

Radiant energy collection and conversion apparatus and method  

SciTech Connect

The apparatus for collecting radiant energy and converting same to alternate energy form includes a housing having an interior space and a radiation transparent window allowing, for example, solar radiation to be received in the interior space of the housing. Means are provided for passing a stream of fluid past said window and for injecting radiation absorbent particles in said fluid stream. The particles absorb the radiation and because of their very large surface area, quickly release the heat to the surrounding fluid stream. The fluid stream particle mixture is heated until the particles vaporize. The fluid stream is then allowed to expand in, for example, a gas turbine to produce mechanical energy. In an aspect of the present invention properly sized particles need not be vaporized prior to the entrance of the fluid stream into the turbine, as the particles will not damage the turbine blades. In yet another aspect of the invention, conventional fuel injectors are provided to inject fuel into the fluid stream to maintain the proper temperature and pressure of the fluid stream should the source of radiant energy be interrupted. In yet another aspect of the invention, an apparatus is provided which includes means for providing a hot fluid stream having hot particles disbursed therein which can radiate energy, means for providing a cooler fluid stream having cooler particles disbursed therein, which particles can absorb radiant energy and means for passing the hot fluid stream adjacent the cooler fluid stream to warm the cooler fluid and cooler particles by the radiation from the hot fluid and hot particles.

Hunt, Arlon J. (Oakland, CA)

1982-01-01T23:59:59.000Z

157

Portable Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Portable Heaters Portable Heaters Portable Heaters November 26, 2013 - 2:41pm Addthis Portable heaters can be an efficient way to supplement inadequate heating. | Photo courtesy iStockphoto.com Portable heaters can be an efficient way to supplement inadequate heating. | Photo courtesy iStockphoto.com What does this mean for me? A portable heater is a good choice if you have a space that requires supplemental heating or is infrequently occupied. You should carefully follow all the manufacturer's installation and operation instructions. Small space heaters are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. In some cases, small space heaters can be less expensive to use if you only want to heat one room or supplement inadequate heating in one room. They

158

Energy Basics: Small Space Heaters  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

allowing the heater to cycle less and to provide a more constant heat source. More Information Visit the Energy Saver website for more information about portable heaters in homes...

159

Cost of Increased Energy Efficiency for Residential Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

Cost of Increased Energy Efficiency for Residential Water Heaters Cost of Increased Energy Efficiency for Residential Water Heaters Speaker(s): Alex Lekov Date: March 22, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Julie Osborn This presentation describes the analysis of the costs of increased energy efficiency for residential water heaters. Here, we focus on the cost and efficiency data for electric and gas-fired water heaters. This data formed the basis of the Technical Support Document for the Department of Energy's (DOE) Final Rule on Water Heaters. The engineering analysis uses computer simulation models to investigate the efficiency improvements due to design options and combinations thereof. The analysis covers four polyurethane foam insulation types based on non-ozone-depleting substances as blowing

160

Modeling of Residential Attics with Radiant Barriers  

E-Print Network (OSTI)

This paper gives a summary of the efforts at ORNL in modeling residential attics with radiant barriers. Analytical models based on a system of macroscopic heat balances have been developed. Separate models have been developed for horizontal radiant barriers laid on top of the insulation, and for radiant barriers attached to the bottom of the top chords of the attic trusses. The models include features such as a radiation interchange analysis within the attic space, convective coupling with the ventilation air, and sorption/desorption of moisture at surfaces facing the attic enclosure. The paper gives details of the models and the engineering assumptions that were made in their development. The paper also reports on the status of efforts that are underway to verify the models by comparing their predictions with the results of laboratory and field tests on residential attics and test cells, both with and without radiant barriers. Comparisons are given for a number of selected sets of experimental data. Suggestions are given for needed model refinements and additional experimental data. Plans for utilization of the models for extrapolation to seasonal and annual performance in a variety of climatic conditions are also described.

Wilkes, K. E.

1988-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Cooling energy measurements of houses with attics containing radiant barriers  

Science Conference Proceedings (OSTI)

Tests were conducted by Oak Ridge National Laboratory (ORNL) to determine the magnitude of the energy savings brought about by installing radiant barriers in the attics of single-family houses. The radiant barrier used for this test was a product with two reflective aluminum surfaces on a kraft paper base. The radiant barrier has the potential to reduce the radiant heat transfer component impinging on the fiberglass attic insulation. Working as a system in conjunction with an air space, the radiant barrier could theoretically block up to 95% of far-infrared radiation heat transfer. The results showed a savings in the cooling loads of 21% when the radiant barrier was laid on top of the attic fiberglass insulation and 13% with the radiant barrier attached to the underside of the roof trusses. The savings in electrical consumption was 17% and 9%, respectively.

Levins, W.P.; Karnitz, M.A.; Knight, D.K.

1986-01-01T23:59:59.000Z

162

Immersible solar heater for fluids  

DOE Patents (OSTI)

An immersible solar heater comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

Kronberg, James W. (Aiken, SC)

1995-01-01T23:59:59.000Z

163

Energy Efficiency Design Options for Residential Water Heaters: Economic Impacts on Consumers  

SciTech Connect

The U.S. Department of Energy (DOE) recently completed a rulemaking process in which it amended the existing energy efficiency standards for residential water heaters. A key factor in DOE?s consideration of new standards is the economic impacts on consumers. Determining such impacts requires a comparison of the additional first cost of energy efficiency design options with the savings in operating costs. This paper describes the method used to conduct the life-cycle cost (LCC) and payback period analysis for gas and electric storage water heaters. It presents the estimated change in LCC associated with more energy-efficient equipment, including heat pump electric water heaters and condensing gas water heaters, for a representative sample of U.S. homes. The study included a detailed accounting of installation costs for the considered design options, with a focus on approaches for accommodating the larger dimensions of more efficient water heaters. For heat pump water heaters, the study also considered airflow requirements, venting issues, and the impact of these products on the indoor environment. The results indicate that efficiency improvement relative to the baseline design reduces the LCC in the majority of homes for both gas and electric storage water heaters, and heat pump electric water heaters and condensing gas water heaters provide a lower LCC for homes with large rated volume water heaters.

Lekov, Alex; Franco, Victor; Meyers, Steve; Thompson, Lisa; Letschert, Virginie

2010-11-24T23:59:59.000Z

164

$69 solar water heater  

SciTech Connect

The construction of a batch or breadbox solar water heater is described in which it is assumed that an old refrigerator and used galvanized air compressor tank are available (at no charge). Additional materials required (plumbing, hardware, lumber, and miscellaneous) cost approximately $69. The refrigerator serves as an insulated box as well as a built-in hinged adjustable reflector (the door). The door also provides tight-fitting nighttime insulation. Detailed directions are provided for the construction of the solar water heater; the principal operations involve modification of the refrigerator, plumbing the tank, constructing the glazing section, and tilting the collector properly. Ample illustrations are provided and a complete list of materials needed is included. The project can be completed in one day. (MJJ)

Morris, E.

1980-09-01T23:59:59.000Z

165

Radiant Electric Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Electric Coop, Inc Electric Coop, Inc Jump to: navigation, search Name Radiant Electric Coop, Inc Place Kansas Utility Id 15621 Utility Location Yes Ownership C NERC Location SPP Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates Residential: $0.1140/kWh Commercial: $0.1080/kWh Industrial: $0.0533/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Radiant_Electric_Coop,_Inc&oldid=411420" Categories: EIA Utility Companies and Aliases

166

Cooling load differences between radiant and air systems  

E-Print Network (OSTI)

the effect of thermal mass on cooling loads, and thereforelift radiant cooling using building thermal mass, Departmentlevel thermal modelling are recommended for design cooling

Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

2013-01-01T23:59:59.000Z

167

Water heater control module  

DOE Patents (OSTI)

An advanced electric water heater control system that interfaces with a high temperature cut-off thermostat and an upper regulating thermostat. The system includes a control module that is electrically connected to the high-temperature cut-off thermostat and the upper regulating thermostat. The control module includes a switch to open or close the high-temperature cut-off thermostat and the upper regulating thermostat. The control module further includes circuitry configured to control said switch in response to a signal selected from the group of an autonomous signal, a communicated signal, and combinations thereof.

Hammerstrom, Donald J

2013-11-26T23:59:59.000Z

168

Heater element design for electrically powered heater assemblies  

DOE Patents (OSTI)

This invention is comprised of an apparatus for electrically simulating a nuclear reactor fuel assembly. It includes a heater assembly having a top end and a bottom end and a plurality of concentric heater tubes having electrical circuitry connected to a power source, and radially spaced from each other. An outer target tube and an inner target tube is concentric with the heater tubes and with each other, and the outer target tube surrounds and is radially spaced from the heater tubes. The inner target tube is surrounded by and radially spaced from the heater tubes and outer target tube. The top of the assembly is generally open to allow for the electrical power connection to the heater tubes, and the bottom of the assembly includes means for completing the electrical circuitry in the heater tubes to provide electrical resistance heating to simulate the power profile in a nuclear reactor. The embedded conductor elements in each heater tube is split into two halves for a substantial portion of its length and provided with electrical isolation such that each half of the conductor is joined at one end and is not joined at the other end.

Berta, V.T.

1992-12-31T23:59:59.000Z

169

THERMOSIPHON WATER HEATERS WITH HEAT EXCHANGERS  

E-Print Network (OSTI)

The Performance of Solar Water Heater With Natural Ci rculperformance of solar thermos i phon water heaters with heatSolar Jubilee, Phoenix, AZ, June 2-6, 1980 THERMOSIPHON WATER HEATERS

Mertol, Atila

2012-01-01T23:59:59.000Z

170

MEAN MONTHLY PERFORMANCE OF PASSIVE SOLAR HEATERS  

E-Print Network (OSTI)

PERFORMANCE OF PASSIVE SOLAR WATER HEATERS W. Place, M.PERFORMANCE OF PASSIVE SOLAR WATER HEATERS* We Place, M.The Performance of Solar Water Heaters with Natu)""al

Place, W.

2011-01-01T23:59:59.000Z

171

Solar Water Heater Basics | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Solar Water Heater Basics Solar Water Heater Basics August 19, 2013 - 3:01pm Addthis Illustration of an active, closed loop solar water heater. A large, flat panel called a flat...

172

Do You Have a Solar Water Heater?  

Energy.gov (U.S. Department of Energy (DOE))

Earlier this week, Ernie wrote about the economics of getting a solar water heater. As Ernie explained, a solar water heater is more expensive than a normal water heater, but depending on your area...

173

Conventional Storage Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conventional Storage Water Heaters Conventional Storage Water Heaters July 30, 2013 - 3:39pm Addthis Illustration showing the components of a storage water heater. On top of the...

174

Heat Pump Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heaters Heat Pump Water Heaters August 19, 2013 - 2:59pm Addthis Illustration of a heat pump water heater, which looks like a tall cylinder with a small chamber on top and a...

175

Solar Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heaters Solar Water Heaters August 19, 2013 - 3:01pm Addthis Illustration of an active, closed loop solar water heater. A large, flat panel called a flat plate...

176

Tankless Demand Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Demand Water Heaters Tankless Demand Water Heaters August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is...

177

Impact of Solar Heat Gain on Radiant Floor Cooling System Design  

E-Print Network (OSTI)

Bauman F. 2013. Impact of Solar Heat Gain on Radiant FloorBauman F. 2013. Impact of Solar Heat Gain on Radiant FloorBauman F. 2013. Impact of Solar Heat Gain on Radiant Floor

Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

2013-01-01T23:59:59.000Z

178

Subsurface heaters with low sulfidation rates  

SciTech Connect

A system for heating a hydrocarbon containing formation includes a heater having an elongated ferromagnetic metal heater section. The heater is located in an opening in a formation. The heater section is configured to heat the hydrocarbon containing formation. The exposed ferromagnetic metal has a sulfidation rate that goes down with increasing temperature of the heater, when the heater is in a selected temperature range.

John, Randy Carl; Vinegar, Harold J

2013-12-10T23:59:59.000Z

179

Radiant Energy Power Source for Jet Aircraft  

DOE Green Energy (OSTI)

This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.

Doellner, O.L.

1992-02-01T23:59:59.000Z

180

Vented Cavity Radiant Barrier Assembly And Method  

DOE Patents (OSTI)

A vented cavity radiant barrier assembly (2) includes a barrier (12), typically a PV module, having inner and outer surfaces (18, 22). A support assembly (14) is secured to the barrier and extends inwardly from the inner surface of the barrier to a building surface (14) creating a vented cavity (24) between the building surface and the barrier inner surface. A low emissivity element (20) is mounted at or between the building surface and the barrier inner surface. At least part of the cavity exit (30) is higher than the cavity entrance (28) to promote cooling air flow through the cavity.

Dinwoodie, Thomas L. (Piedmont, CA); Jackaway, Adam D. (Berkeley, CA)

2000-05-16T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Grid Friendly™ Water Heater Controller - Available ...  

Summary. The Grid Friendly™ Water Heater Controller is a device that provides smart grid services from existing, installed electric water heaters.

182

Immersible solar heater for fluids  

DOE Patents (OSTI)

An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater. 11 figs.

Kronberg, J.W.

1995-07-11T23:59:59.000Z

183

Immersible solar heater for fluids  

DOE Patents (OSTI)

An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

Hazen, T.C.; Fliermans, C.B.

1994-01-01T23:59:59.000Z

184

Solar hot water heater  

SciTech Connect

A solar hot water heater includes an insulated box having one or more hot water storage tanks contained inside and further having a lid which may be opened to permit solar radiation to heat a supply of water contained within the one or more hot water storage tanks. A heat-actuated control unit is mounted on an external portion of the box, such control unit having a single pole double throw thermostat which selectively activates an electric winch gear motor to either open or close the box lid. The control unit operates to open the lid to a predetermined position when exposed to the sun's rays, and further operates to immediately close the lid in response to any sudden drop in temperature, such as might occur during a rainstorm, clouds moving in front of the sun, or the like.

Melvin, H.A.

1982-12-28T23:59:59.000Z

185

Cooling Energy Measurements of Houses with Attics Containing Radiant Barriers  

E-Print Network (OSTI)

Tests were conducted by Oak Ridge National Laboratory (ORNL) to determine the magnitude of the energy savings brought about by installing radiant barriers in the attics of single-family houses. The radiant barrier used for this test was a product with two reflective aluminum surfaces on a kraft paper base. The radiant barrier has the potential to reduce the radiant heat transfer component impinging on the fiberglass attic insulation. Working as a system in conjunction with an air space, the radiant barrier could theoretically block up to 95% of far-infrared radiation heat transfer. The experiment was conducted in three unoccupied research houses that are operated by ORNL. One house was used as the control house (no barrier was installed), while the other two were used to test the two different methods for installing the radiant barriers. In one house, the barrier was laid on top of the attic fiberglass batt insulation, and in the other house, the barrier was attached to the underside of the roof trusses. The attics of all three houses were insulated with kraft paper faced nominal R-19 fiberglass batt insulation. The results showed a savings in the cooling loads of 21% when the radiant barrier was laid on top of the attic fiberglass insulation and 13% with the radiant barrier attached to the underside of the roof trusses. The savings in electrical consumption was 17% and 9%, respectively. The electrical consumption data and the cooling load data indicated that the most effective way of installing the foil was to lay it on top of the fiberglass batt insulation. The radiant barriers reduced the measured peak ceiling heat fluxes by 39% for the case where the barrier was laid on top of the attic fiberglass insulation. The radiant barrier reduced the integrated heat flows from the attic to house by approximately 30-35% over a 7-day time period.

Levins, W. P.; Karnitz, M. A.; Knight, D. K.

1986-01-01T23:59:59.000Z

186

THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER  

E-Print Network (OSTI)

of houses with a high perfor- mance heat pump as well as resistance, gas, and oil heated houses with a high#12;THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER Laboratory testing and field testing have shown that a heat pump water heater (HPWH) uses about half the electrical

Oak Ridge National Laboratory

187

Tuning The Laser Heater Undulator  

Science Conference Proceedings (OSTI)

The laser heater undulator for the LCLS requires different tuning techniques than the main undulators. It is a pure permanent magnet (PPM) undulator, rather than the hybrid design of the main undulators. The PPM design allows analytic calculation of the undulator fields. The calculations let errors be introduced and correction techniques be derived. This note describes how the undulator was modelled, and the methods which were found to correct potential errors in the undulator. The laser heater undulator for the LCLS is a pure permanent magnet device requiring different tuning techniques than the main undulators. In this note, the laser heater undulator is modelled and tuning techniques to compensate various errors are derived.

Wolf, Zackary

2010-12-03T23:59:59.000Z

188

Restoration of Refinery Heaters Using the Technique of Prefabricated Ceramic Fiber Lined Panels  

E-Print Network (OSTI)

Refinery heater fuel requirements often represent 50% of a units operating cost. A one percent change in the efficiency of a heater firing 100 MBtu/hr amounts to more than $25,000 per year. Heater efficiency is influenced by casing hot spots, air leakage, corbel damage, flue gas obstruction and dirty tubes. Efficiency impact is greatest in the convection section since conventional repairs only permit accessing from the outside, thus only hot spots and some air leakage are repaired. Exxon USA's Baton Rouge refinery has adopted a restoration procedure, using the technique of ceramic fiber lined panels, which corrects all the problem areas and returns the heater to new condition. Restorations have been successfully completed on convection sections as well as total heaters. All restorations have been within a normal turnaround period. Efficiency increases greater than 3% have been realized, as well as improvements in the heater's operation.

Sento, H. D.

1981-01-01T23:59:59.000Z

189

Radiant Technology Corporation RTC | Open Energy Information  

Open Energy Info (EERE)

Technology Corporation RTC Technology Corporation RTC Jump to: navigation, search Name Radiant Technology Corporation (RTC) Place Fullerton, California Zip 92831 Product Provides infrared furnaces, primarily used in the photovoltaic manufacturing industry. Coordinates 46.16041°, -98.420506° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":46.16041,"lon":-98.420506,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

190

MHD air heater development technology. Quarterly report, January-March 1979  

DOE Green Energy (OSTI)

Progress on the ceramic heater development program is reported. The statement of work divides the effort into three tasks. Task 1 (design studies). The objectives of this task are to: (1) evaluate full-scale, directly- and indirectly-fired regenerative air heater systems for use in MHD power plants; (2) support testing of refractory materials, hot gas valves, and design concepts; (3) support design of a 5 MW test heater. Task 2 (design support tests). The objectives of this task are to: (1) support design of a 5 MW test heater; (2) identify and evaluate life of promising refractory materials for use in MHD heaters; (3) determine operating conditions and bed geometry (hole size, web thickness) which permit operation without clogging of heater passages due to accumulations of seed/slag or slag alone, (4) test valves for use in hot gas steams which are laden with seed/slag or slag alone. Task 3 (vertical slice test bed). The objective of this task is to provide a preliminary design of a test heater which is a vertical slice of a full-scale heater. It will be sized for a thermal input of approximately 5 MW. Testing with hot gas steams containing seed/slag or slag alone will be accommodated in order to simulate both direct- and indirect-firing. (WHK)

None

1979-07-01T23:59:59.000Z

191

Piedmont Natural Gas- Residential Equipment Efficiency Program  

Energy.gov (U.S. Department of Energy (DOE))

Piedmont Natural Gas offers rebates on high-efficiency natural gas tankless water heaters, tank water heaters and furnaces. Customers on the 201-Residential Service Rate or 221-Residential Service...

192

Central Hudson Gas & Electric (Gas) - Residential Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

of energy efficient equipment. Natural gas rebates apply to water heaters, natural gas boilers, steam boilers, boiler controls, furnaces, programmable thermostats, and duct and air...

193

Moisture Measurements in Residential Attics Containing Radiant Barriers  

Science Conference Proceedings (OSTI)

Horizontal radiant barriers, rigorously tested during a typical Tennessee winter, allowed moisture to dissipate on a diurnal cycle and caused no structural, wet insulation, or stained-ceiling problems.

1989-08-21T23:59:59.000Z

194

Conventional Storage Water Heater Basics | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics July 30, 2013 - 3:39pm Addthis Illustration showing the components of a storage water heater. On...

195

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

2001. Residential Heat Pump Water Heater (HPWH) DevelopmentKelso, J. 2003. Incorporating Water Heater Replacement into2005. Residential Heat Pump Water Heaters: Energy Efficiency

Franco, Victor

2011-01-01T23:59:59.000Z

196

Heat Pump Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heaters Water Heaters Heat Pump Water Heaters May 4, 2012 - 5:21pm Addthis A diagram of a heat pump water heater. A diagram of a heat pump water heater. What does this mean for me? Heat pump water heaters can be two to three times more energy efficient than conventional electric storage water heaters. Heat pump water heaters work in locations that remain in the 40Âș-90ÂșF range year-round. Most homeowners who have heat pumps use them to heat and cool their homes. But a heat pump also can be used to heat water -- either as stand-alone water heating system, or as combination water heating and space conditioning system. How They Work Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. Therefore, they can be two to

197

Influence of Dust on the Emissivity of Radiant Barriers  

E-Print Network (OSTI)

A model of the radiant heat transfer in attics containing dusty radiant barriers was developed. The geometrical model was a triangular enclosure in which the temperatures of the enclosing surfaces were known. The dust particles were simulated as areas of diameter equal to the mean diameter of the real dust to be analyzed and an emissivity substantially larger than the emissivity of the radiant barrier. Several shape factors were calculated using shape factor algebra, including a procedure to find the shape factor between a small rectangle and a triangular surface perpendicular to the rectangular plane. The thermal model was developed using the "Net Radiation Method" in which the net heat exchange between the surfaces surrounding the enclosure was found by solving a system of equations that has as many equations as the number of surfaces involved in the calculations. This led to the necessity of solving a very large system of equations in order to account for the dust particles in a representative amount. The solution of the system of equations provided the heat flux for each element of the enclosure. Finally, replacing the radiant barrier and the dust particles for an equivalent surface corresponding to the dusty radiant barrier provided the means to calculate the emissivity of this dusty radiant barrier. The theoretical model was tested to assess its validity. The experimentation was carried out using a reflection emissometer to measure the increase of the emissivity of aluminum radiant barrier when known quantities of dust were artificially applied to it. The experimental results showed good agreement with the theoretical model. A linear relationship between the emissivity and the area of dust coverage was found. The simple relation developed can be used in future research which still has to deal with the determination of the area of dust coverage by using the geometrical model of dust superposition or other statistical model to simulate the random location of random size dust particles over the radiant barrier.

Noboa, Homero L.

1991-12-01T23:59:59.000Z

198

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

E-Print Network (OSTI)

heater storage tank wastes energy to continuous heating.fired water heater Total Energy Total Waste Emissions (Air)fired water heater Total Energy Total Waste Emissions (Air)

Lu, Alison

2011-01-01T23:59:59.000Z

199

Advanced Process Heater  

SciTech Connect

The Roadmap for Process Heating Technology (March 16, 2001), identified the following priority R&D needs: Improved performance of high temperature materials; Improved methods for stabilizing low emission flames; Heating technologies that simultaneously reduce emissions, increase efficiency, and increase heat transfer. This Category I award entitled ''Proof of Concept of an Advanced Process Heater (APH) for Steel, Aluminum, and Petroleum Industries of the Future'' met the technical feasibility goals of: (1) Doubling the heat transfer rates (2) Improving thermal efficiencies by 20%, (3) Improving temperature uniformity by 100 degrees F and (4) simultaneously reducing NOx and CO2 emissions. The APH address EERE's mission priority of increasing efficiency/reducing fuel usage in energy intensive industries. One component of the APH, the SpyroCorTM, was commercialized by STORM Development's partner, Spinworks LLC. Over 2000 SpyrCorsTM were sold in 2004 resulting in 480 million BTU's of energy savings, 20% reduction in NOx and CO2 levels, and 9 jobs in N.W. Pennsylvania. A second component, the HeatCorTM, a low-cost high-temperature heat exchanger will be demonstrated by Spinworks in 2005 in preparation for commercial sales in 2006. The project occurred in the 21st Congressional District of Pennsylvania. Once fully commercialized, the APH energy savings potential is 339 trillion BTUs annually in the U.S. and will process 1.5 million more tons annually without major capital equipment expenditures. Spinworks will commercialize the APH and add over 100 U.S. workers. To accomplish the objective, STORM Development LLC teamed with Penn State University, SyCore, Inc, Spinworks LLC, and Schunk-INEX, Inc. The project consisted of component engineering and integration of the APH followed by parametric testing. All components of the system were tested in a lab furnace that simulates a full scale industrial installation. The target areas for development include: (1) Scale up STORM's Finned Stabilized Combustion, (2) Optimization of SyCore's SiGr Inserts such that the heat transfer on the exhaust leg will match the high luminosity burner leg., (3) Evaluation of the heat transfer characteristics of Schunk-INEX's finned composite tubes as a heat exchanger, and (4) Design of a system to monitor all components of the APH and control its performance such that the objectives are met.

Tom Briselden, Chris Parrish

2005-03-07T23:59:59.000Z

200

Energy Conservation in Process Heaters  

E-Print Network (OSTI)

Energy savings in refinery and petrochemical fired heaters can basically be achieved in two ways: Thru optimization on energy use which can be done with small or no investments, or with extensive energy recovery systems. Various alternatives for the first case are given while the second concept is examined in more detail. Upgrading of heater efficiency should primarily aim at transferring as much energy as feasible to the actual process. When this is not possible the secondary target should be energy recycling in the combustion process by air preheating systems. The third possibility to re-use waste energy is recovery by utility systems like waste heat boilers. This paper gives an overview of different approaches to energy conservation in process heaters. It also includes the concepts, design considerations, apparatus, profitability aspects and actual operating experience.

Bagge, R. W.

1982-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

SciTech Connect

Residential water heating is a large source of energy use in California homes. This project took a life cycle approach to comparing tank and tankless water heaters in Northern and Southern California. Information about the life cycle phases was calculated using the European Union?s Methodology study for EcoDesign of Energy-using Products (MEEUP) and the National Renewable Energy Laboratory?s Life Cycle Inventory (NREL LCI) database. In a unit-to-unit comparison, it was found that tankless water heaters would lessen impacts of water heating by reducing annual energy use by 2800 MJ/year (16% compared to tank), and reducing global warming emissions by 175 kg CO2 eqv./year (18% reduction). Overall, the production and combustion of natural gas in the use phase had the largest impact. Total waste, VOCs, PAHs, particulate matter, and heavy-metals-to-air categories were also affected relatively strongly by manufacturing processes. It was estimated that tankless water heater users would have to use 10 more gallons of hot water a day (an increased usage of approximately 20%) to have the same impact as tank water heaters. The project results suggest that if a higher percentage of Californians used tankless water heaters, environmental impacts caused by water heating would be smaller.

Lu, Alison; McMahon, James; Masanet, Eric; Lutz, Jim

2008-08-13T23:59:59.000Z

202

Tankless or Demand-Type Water Heaters | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

or Demand-Type Water Heaters May 2, 2012 - 6:47pm Addthis Diagram of a tankless water heater. Diagram of a tankless water heater. How does it work? Tankless water heaters deliver...

203

Selecting a New Water Heater | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Selecting a New Water Heater Selecting a New Water Heater August 29, 2012 - 7:30pm Addthis Water heater testing facility at Oak Ridge National Laboratory. Water heater testing...

204

Tankless Coil and Indirect Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters August 19, 2013 - 3:03pm Addthis Illustration of a tankless coil water heater. The heater is...

205

Feedwater Heater Technology Seminar and Symposium  

Science Conference Proceedings (OSTI)

Feedwater heater and associated systems performance strongly affects availability and heat rate in fossil and nuclear power plants. Fifteen papers were presented at a 2001 symposium to discuss industrial experience and case histories of feedwater heater problems and solutions.

2001-09-17T23:59:59.000Z

206

Storage Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Storage Water Heaters Storage Water Heaters Storage Water Heaters June 15, 2012 - 6:00pm Addthis Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of ©iStockphoto/JulNichols. Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of ©iStockphoto/JulNichols. Conventional storage water heaters remain the most popular type of water heating system for the home. Here you'll find basic information about how storage water heaters work; what criteria to use when selecting the right model; and some installation, maintenance, and safety tips. How They Work A single-family storage water heater offers a ready reservoir -- from 20 to

207

Energy Basics: Tankless Demand Water Heaters  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

only as needed and without the use of a storage tank. They don't produce the standby energy losses associated with storage water heaters. How Demand Water Heaters Work Demand...

208

MHD air heater development technology. Report for the period April 1978-June 1978  

DOE Green Energy (OSTI)

This research program is divided into three tasks. Task 1 (design studies): the objectives of this task are to: (1) evaluate full-scale, direct- and indirect-fired regenerative air heater systems for use in MHD power plants; (2) support testing of refractory materials, hot gas valves, and design concepts; (3) support design of a 5 MW test heater. Task 2 (design support tests): the objectives of this task are to: (1) support design of a 5 MW test heater; (2) identify and evaluate life of promising refractory materials for use in MHD heaters; (3) determine operating conditions and bed geometry (hole size, web thickness) which permit operation without clogging of heater passages due to accumulations of seed/slag or slag alone, (4) test valves for use in hot gas streams which are laden with seed/slag or slag alone. Task 3 (vertical slice test bed): the objective of this task is to provide a preliminary design of a test heater which is a vertical slice of a full-scale heater. It will be sized for a thermal input of 5 MW. Testing with hot gas streams containing seed/slag or slag alone will be accommodated in order to simulate both direct- and indirect-firing. Progress on each of these tasks is described. (WHK)

None

1978-12-01T23:59:59.000Z

209

MHD air heater development technology. Report for the period July, 1978-September, 1978  

DOE Green Energy (OSTI)

The statement of work divides the effort into three tasks: Task 1 (design studies): The objectives of this task are to: (1) evaluate full-scale, direct- and indirect-fired regenerative air heater systems from use in MHD power plants; (2) support testing of refractory materials, hot gas valves, and design concepts; (3) support design of a 5 MW test heater. Task 2 (design support tests): The objectives of this task are to: (1) support design of a 5 MW test heater; (2) identify and evaluate life of promising refractory materials for use in MHD heaters; (3) determine operating conditions and bed geometry (hole size, web thickness which permit operation without clogging of heater passages due to accumulations of seed/slag or slag alone, (4) test valves for use in hot gas streams which are laden with seed/slag or slag alone. Task 3 (vertical slice test bed): The ojbective of this task is to provide a preliminary design of a test heater which is a vertical slice of a full-sclae heater. It will be sized for a thermal input of approx. 5 MW. Testing with hot gas streams containing seed/slag or slag alone will be accommodated in order to simulate both direct-and indirect-diring. Progress is reported in detail on these tasks.

Not Available

1979-01-01T23:59:59.000Z

210

Conventional Storage Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics July 30, 2013 - 3:39pm Addthis Illustration showing the components of a storage water heater. On top of the tank are two thin pipes; one pipe is the hot water outlet, and the other is the cold water inlet. A large pipe in the middle is called a vent pipe. A pressure/temperature relief valve is also on top of the tank and is connected to an open pipe that runs down the side of the tank. Another valve near the bottom of the outside of the tank is the thermostat and gas valve. A cutout shows the parts inside the tank, which include a large tube called a flue tube/heat exchanger. Inside this tube is a jagged insert called a flue baffle. Beside the flue tube/heat exchanger is a thin tube called the anode rod. At the bottom of the tank is a gas burner, and beneath the burner are combustion air openings.

211

Effect of attic ventilation on the performance of radiant barriers  

Science Conference Proceedings (OSTI)

The objective of the experiments was to quantify how attic ventilation would affect the performance of a radiant barrier. Ceiling heat flux and space cooling load were both measured. Results of side-by-side radiant barrier experiments using two identical 13.38 m[sup 2] (nominal) test houses are presented in this paper. The test houses responded similarly to weather variations. Indoor temperatures of the test houses were controlled to within 0.2 [degrees] C. Ceiling heat fluxes and space cooling load were within a 2.5 percent difference between both test houses. The results showed that a critical attic ventilation flow rate of 1.3 (1/sec)/m[sup 2] of the attic floor existed after which the percentage reduction in ceiling heat fluxes produced by the radiant barriers did not change with increasing attic airflow rates. The ceiling heat flux reductions produced by the radiant barriers were between 25 and 35 percent, with 28 percent being the percent reduction observed most often in the presence of attic ventilation. The space-cooling load reductions observed were between two to four percent. All results compiled in this paper were for attics with unfaced fiberglass insulation with a resistance level of 3.35 m[sup 2]K/W (nominal) and for a perforated radiant barrier with low emissivities (less than 0.05) on both sides.

Medina, M.A.; O'Neal, D.L. (Texas A and M Univ., College Station, TX (United States). Dept. of Mechanical Engineering); Turner, W.D. (Texas A and M Univ., College Station, TX (United States). Coll. of Engineering)

1992-11-01T23:59:59.000Z

212

Federal Energy Management Program: Covered Product Category: Gas Storage  

NLE Websites -- All DOE Office Websites (Extended Search)

Gas Storage Water Heaters to someone by E-mail Gas Storage Water Heaters to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Gas Storage Water Heaters on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Gas Storage Water Heaters on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Gas Storage Water Heaters on Google Bookmark Federal Energy Management Program: Covered Product Category: Gas Storage Water Heaters on Delicious Rank Federal Energy Management Program: Covered Product Category: Gas Storage Water Heaters on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Gas Storage Water Heaters on AddThis.com... Energy-Efficient Products Federal Requirements Covered Product Categories

213

Solar Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heater Basics Solar Water Heater Basics Solar Water Heater Basics August 19, 2013 - 3:01pm Addthis Illustration of an active, closed loop solar water heater. A large, flat panel called a flat plate collector is connected to a tank called a solar storage/backup water heater by two pipes. One of these pipes runs through a cylindrical pump into the bottom of the tank, where it becomes a coil called a double-wall heat exchanger. This coil runs up through the tank and out again to the flat plate collector. Antifreeze fluid runs only through this collector loop. Two pipes run out the top of the water heater tank; one is a cold water supply into the tank, and the other sends hot water to the house. Solar water heaters use the sun's heat to provide hot water for a home or

214

The Influence of Dust on the Absorptivity of Radiant Barriers  

E-Print Network (OSTI)

The purpose of this project was to model and quantify the increase of the absorptivity of radiant barriers caused by the accumulation of dust on the surface of radiant barriers. This research was the continuation of a previous work by the author at Texas A&M University in which a radiation energy balance inside the attic enclosure was developed. The particles were considered as flat, circular planes, all having the same radii. That early model showed that there was a linear relationship between the fraction of area of the foil covered by dust and the mean absorptivity of the dusty radiant barrier. In the present work, it was found that the assumption of treating the dust particles as plane circles, underestimated the effective area of the particles by about 20%. Experimental measurements indicated that dust particles achieved the same temperature as the radiant barrier. The new model used the linear relationship just described, and simulated the dust particles as flat circular planes having random radii and laying in random locations within the radiant barrier surface. The new model calculated the fraction of radiant barrier area covered by particles using a digital array in which the clean barrier was represented as zeroes and the dust particles were represented as a set of ones appropriately dimensioned inside the array. The experimentation used natural dust and Arizona Road Test Dust. Using an infrared emissometer, the emissivities (absorptivities) of the clean and dusty barriers were measured and using an electronic scale, the dust loading was measured. An electron microscope was used to experimentally find the fraction of radiant barrier covered by the dust particles to correlate the experimentally found absorptivity with the experimentally found fraction of dust coverage. The limited experimental data available were also used to correlate the absorptivity of the dusty radiant barrier with the time of dust accumulation and the location of the barrier inside the attic. A linear relationship between the absorptivity and the time of dust accumulation was found that can be applied to predict future barrier effectiveness based upon the rate of dust accumulation for a given location.

Noboa, Homero L.

1993-08-01T23:59:59.000Z

215

Dust and Ventilation Effects on Radiant Barriers: Cooling Season Energy Measurements  

Science Conference Proceedings (OSTI)

This study on the effects of attic ventilation area and type and dust buildup on horizontal and truss radiant barriers in insulated homes can help utilities reduce cooling season electric energy requirements. Increasing the ventilation area ratio and changing ventilation types had little effect on radiant barrier performance. Dust did degrade performance, but insulated homes with radiant barriers still had lower energy requirements than those without radiant barriers.

1990-05-15T23:59:59.000Z

216

Piedmont Natural Gas- Commercial Equipment Efficiency Program  

Energy.gov (U.S. Department of Energy (DOE))

Piedmont Natural Gas offers rebates to commercial customers for purchasing and installing high-efficiency natural gas tankless water heaters. Customers on the 202-Small General Service Standard...

217

Integral finned heater and cooler for stirling engines  

DOE Patents (OSTI)

A piston and cylinder for a Stirling engine and the like having top and bottom meshing or nesting finned conical surfaces to provide large surface areas in close proximity to the working gas for good thermal (addition and subtraction of heat) exchange to the working gas and elimination of the usual heater and cooler dead volume. The piston fins at the hot end of the cylinder are perforated to permit the gas to pass into the piston interior and through a regenerator contained therein.

Corey, John A. (North Troy, NY)

1984-01-01T23:59:59.000Z

218

Efficiency Maine Business Programs (Unitil Gas) - Commercial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Boilers: 750-3,000 Steam Boiler: 800 or 1MBtuh Infrared Unit Heaters: 500 Natural Gas Warm-Air Unit Heaters: 600 CustomECM: Contact Unitil Cooking Equipment: 600-2000...

219

Chiller-heater unit nets building 2-yr payback  

SciTech Connect

A 500-ton double-absorption Hitachi Paraflow chiller-heater that switches from purchased steam to natural gas will reduce a Manhattan office building's energy costs by 55% and achieve a two-year payback. The new system replaces a steam-powered, single-stage absorption chiller. By reusing heat in a second-stage generator, the Hitachi unit uses only half as many Btus per ton as a conventional chiller. (DCK)

Duffy, J.

1983-05-09T23:59:59.000Z

220

Alabama Gas Corporation - Residential Natural Gas Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alabama Gas Corporation - Residential Natural Gas Rebate Program Alabama Gas Corporation - Residential Natural Gas Rebate Program Alabama Gas Corporation - Residential Natural Gas Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Water Heating Program Info State Alabama Program Type Utility Rebate Program Rebate Amount Furnace (Replacement): $200 Dryer (Replacement): $100 Natural Gas Range/Cooktop (Replacement): $100 Water Heaters (Replacement): $200 Tankless Water Heaters (Replacement): $200 Provider Alabama Gas Corporation Alabama Gas Corporation (Alagasco) offers various rebates to its residential customers who replace older furnaces, water heaters, cooktops, ranges and clothes dryers with new, efficient equipment. All equipment

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States  

SciTech Connect

Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

2013-07-01T23:59:59.000Z

222

Fact Sheet Radiant barriers and interior radiation control  

E-Print Network (OSTI)

the insulation, the radiant barrier will lose most of its effectiveness in reducing heating and cooling loads in central Florida. Subsequent monitoring and data analysis showed cooling energy savings of 9%, peak load with air-conditioning ductwork in the attic in the deep south (such as in Miami in Zone 1 or Austin in Zone

Oak Ridge National Laboratory

223

Analysis of annual energy savings due to radiant barriers  

Science Conference Proceedings (OSTI)

Radiant barriers are receiving increasing attention as an energy conservation measure for residential buildings, especially for warmer climates. They are being actively promoted for use in residential attics, sometimes with exaggerated claims about savings in utility bills that will results from their installation. In order to provide consumers with factual information that would assist them in deciding upon an investment in a radiant barrier, the Department of Energy, along with an industry advisory panel, has developed a Radiant Barrier Fact Sheet. A major part of this fact sheet is estimates of energy savings that might be expected from radiant barriers in various climates. This paper presents the details of the methodology underlying the energy savings estimates, and gives a summary of values listed in the Fact Sheet. The energy savings estimates were obtained from calculations using a detailed attic thermal model coupled with DOE-2.1C. A life cycle cost analysis was performed to estimate the present value savings on utility fuel costs. The results show that the fuel cost savings vary significantly with the level of conventional insulation already in the attic and from one climate to another.

Wilkes, K.E.

1990-01-01T23:59:59.000Z

224

Lid heater for glass melter  

DOE Patents (OSTI)

This invention is comprised of a glass melter having a lid electrode for heating the glass melt radiantly. The electrode comprises a series of INCONEL 690 tubes running above the melt across the melter interior and through the melter walls and having nickel cores inside the tubes beginning where the tubes leave the melter interior and nickel connectors to connect the tubes electrically in series. An applied voltage causes the tubes to generate heat of electrical resistance for melting frit injected onto the melt. The cores limit heat generated as the current passes through the walls of the melter. Nickel bus connection to the electrical power supply minimizes heat transfer away from the melter that would occur if standard copper or water-cooled copper connections were used between the supply and the INCONEL 690 heating tubes.

Phillips, T.D.

1992-12-31T23:59:59.000Z

225

Lid heater for glass melter  

DOE Patents (OSTI)

A glass melter having a lid electrode for heating the glass melt radiantly. The electrode comprises a series of INCONEL 690 tubes running above the melt across the melter interior and through the melter walls and having nickel cores inside the tubes beginning where the tubes leave the melter interior and nickel connectors to connect the tubes electrically in series. An applied voltage causes the tubes to generate heat of electrical resistance for melting frit injected onto the melt. The cores limit heat generated as the current passes through the walls of the melter. Nickel bus connection to the electrical power supply minimizes heat transfer away from the melter that would occur if standard copper or water-cooled copper connections were used between the supply and the INCONEL 690 heating tubes. 3 figures.

Phillips, T.D.

1993-12-14T23:59:59.000Z

226

Joint used for coupling long heaters  

DOE Patents (OSTI)

Systems for coupling ends of elongated heaters and methods of using such systems to treat a subsurface formation are described herein. A system may include two elongated heaters with an end portion of one heater abutted or near to an end portion of the other heater and a core coupling material. The core coupling material may extend between the two elongated heaters. The elongated heaters may include cores and at least one conductor substantially concentrically surrounds the cores. The cores may have a lower melting point than the conductors. At least one end portion of the conductor may have a beveled edge. The gap formed by the beveled edge may be filled with a coupling material for coupling the one or more conductors. One end portion of at least one core may have a recessed opening and the core coupling material may be partially inside the recessed opening.

Menottie, James Louis

2013-02-26T23:59:59.000Z

227

Storage Water Heaters | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

6:00pm Addthis Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of iStockphoto...

228

The LBNL Water Heater Retail Price Database  

SciTech Connect

Lawrence Berkeley National Laboratory developed the LBNL Water Heater Price Database to compile and organize information used in the revision of U.S. energy efficiency standards for water heaters. The Database contains all major components that contribute to the consumer cost of water heaters, including basic retail prices, sales taxes, installation costs, and any associated fees. In addition, the Database provides manufacturing data on the features and design characteristics of more than 1100 different water heater models. Data contained in the Database was collected over a two-year period from 1997 to 1999.

Lekov, Alex; Glover, Julie; Lutz, Jim

2000-10-01T23:59:59.000Z

229

Parallel heater system for subsurface formations  

DOE Patents (OSTI)

A heating system for a subsurface formation is disclosed. The system includes a plurality of substantially horizontally oriented or inclined heater sections located in a hydrocarbon containing layer in the formation. At least a portion of two of the heater sections are substantially parallel to each other. The ends of at least two of the heater sections in the layer are electrically coupled to a substantially horizontal, or inclined, electrical conductor oriented substantially perpendicular to the ends of the at least two heater sections.

Harris, Christopher Kelvin (Houston, TX); Karanikas, John Michael (Houston, TX); Nguyen, Scott Vinh (Houston, TX)

2011-10-25T23:59:59.000Z

230

Field Monitoring Protocol: Heat Pump Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

Field Monitoring Protocol: Heat Pump Water Heaters B. Sparn, L. Earle, D. Christensen, J. Maguire, and E. Wilson National Renewable Energy Laboratory C.E. Hancock Mountain Energy...

231

DOE_Water_Heater_Meeting_111612.pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

the request for information "... Energy Conservation Standards for Residential Water Heaters", the comments filed therein, and follow-up items from a previous meeting on...

232

Energy Saving Absorption Heat Pump Water Heater  

energy savings and can reduce the use of fossil fuels by buildings. While conventional heat pump water heater designs are limited to using toxic ammonia water ...

233

Heat Pump Water Heaters—Laboratory Tests  

Science Conference Proceedings (OSTI)

EPRI conducted laboratory tests of several heat pump water heaters to assess their performance and energy efficiency. Among U.S. heat pump water heaters tested were new products from A. O. Smith, General Electric (GE), and Rheem. These units are designed to be integral, drop-in replacements for standard electric water heaters. Additionally, EPRI tested the Japanese-based Eco-cute heat pump water heater from Daikin, which is a split unit with an outdoor heat pump using CO2 as the refrigerant and an indoor...

2009-12-11T23:59:59.000Z

234

Innovative heat exchangers for solar water heaters.  

E-Print Network (OSTI)

??The performance of two innovative collector-loop heat exchangers used in pumped circulation solar water heaters was investigated experimentally and numerically, and TRNSYS simulation models were… (more)

Soo Too, Yen Chean

2007-01-01T23:59:59.000Z

235

Central Hudson Gas & Electric (Gas) - Residential Energy Efficiency...  

Open Energy Info (EERE)

depending on efficiency Natural Gas Water Boiler: 350 - 700, depending on efficiency Steam Boiler: 350 Boiler Reset Control: 70 Indirect Water Heater: 210 Programmable...

236

Alabama Gas Corporation- Residential Natural Gas Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Alabama Gas Corporation (Alagasco) offers various rebates to its residential customers who replace older furnaces, water heaters, cooktops, ranges and clothes dryers with new, efficient equipment....

237

Radiant barriers in houses: Energy, comfort, and moisture considerations in a northern climate  

Science Conference Proceedings (OSTI)

The purpose of this study was to determine the conditions under which radiant barrier utilization in attics is appropriate technology in building construction for a northern climate in Utah. A sample of 12 appropriate houses with radiant barriers were selected using predetermined criteria. Another 12 houses without radiant barriers were selected as a control sample and paired with the first 12 houses using predetermined criteria. The research involved three different types of data and analyses. First, a questionnaire survey was completed by the occupants of the 12 sample houses, with radiant barriers. The survey included such factors as: (1) comfort, (2) energy, and (3) potential increased moisture content as perceived by the occupants. Second, a t-test was used to calculate the statistical comparison of utility usage between the 12 sample houses with radiant barriers and the 12 control houses without radiant barriers. Third, the moisture content of the wood framing above and below the radiant barriers was measured over a three month period during the winter months. Data analysis indicated: (1) occupants did perceive that more comfort resulted from the installation of radiant barriers, (2) occupants did not observe additional moisture artifacts after the installation of radiant barriers, (3) occupants did perceive cost savings from utility benefits resulting from the use of radiant barriers, especially in cooling the houses in summer, (4) there was no significant difference between utility usage of houses with radiant barriers and houses without radiant barriers, (5) the moisture content in the ceiling joists of all 24 houses, except one, had a moisture content measurement less than eight percent, and (6) houses with radiant barriers have higher humidity levels within the living space than houses without radiant barrier installation.

Mendenhall, R.L.

1990-01-01T23:59:59.000Z

238

SINGLE HEATER TEST FINAL REPORT  

SciTech Connect

The Single Heater Test is the first of the in-situ thermal tests conducted by the U.S. Department of Energy as part of its program of characterizing Yucca Mountain in Nevada as the potential site for a proposed deep geologic repository for the disposal of spent nuclear fuel and high-level nuclear waste. The Site Characterization Plan (DOE 1988) contained an extensive plan of in-situ thermal tests aimed at understanding specific aspects of the response of the local rock-mass around the potential repository to the heat from the radioactive decay of the emplaced waste. With the refocusing of the Site Characterization Plan by the ''Civilian Radioactive Waste Management Program Plan'' (DOE 1994), a consolidated thermal testing program emerged by 1995 as documented in the reports ''In-Situ Thermal Testing Program Strategy'' (DOE 1995) and ''Updated In-Situ Thermal Testing Program Strategy'' (CRWMS M&O 1997a). The concept of the Single Heater Test took shape in the summer of 1995 and detailed planning and design of the test started with the beginning fiscal year 1996. The overall objective of the Single Heater Test was to gain an understanding of the coupled thermal, mechanical, hydrological, and chemical processes that are anticipated to occur in the local rock-mass in the potential repository as a result of heat from radioactive decay of the emplaced waste. This included making a priori predictions of the test results using existing models and subsequently refining or modifying the models, on the basis of comparative and interpretive analyses of the measurements and predictions. A second, no less important, objective was to try out, in a full-scale field setting, the various instruments and equipment to be employed in the future on a much larger, more complex, thermal test of longer duration, such as the Drift Scale Test. This ''shake down'' or trial aspect of the Single Heater Test applied not just to the hardware, but also to the teamwork and cooperation between multiple organizations performing their part in the test.

J.B. Cho

1999-05-01T23:59:59.000Z

239

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces  

SciTech Connect

This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

Not Available

1993-11-01T23:59:59.000Z

240

National solar water heater workshop  

Science Conference Proceedings (OSTI)

The National Solar Water Heater Workshop (NSWHW) program directly resolves the major problem inhibiting the widespread application of solar energy for domestic water heating - that of bridging the gap, by an educational program, between well-known solar technology and the application of that technology. This is accomplished by workshop sponsors throughout the nation, conducting workshops to educate homeowners on solar principles, and installation, operation, and maintenance of their solar system. During a workshop, students personally fabricate two or more collectors and complete a plumbing subsystem, all of which have been developed and specified by Arizona State University (ASU). The program appeals to do-it-yourselfers and handyman type persons who by their example become strong solar advocates to their neighbors and acquaintances. A market for the commercial solar industry is thus also generated as other homeowners acquire installed systems from the local solar industry. A central thrust of this program is the establishment of local solar hardware suppliers who can supply the demand of the students for solar hardware kits. This is a DOE program approved for 2 years and is funded at $600,000 for the first year with $400,000 to be funded for the second year. At the end of 2 years, it is envisioned that 50,000 domestic solar water heaters will have been installed throughout the nation and trust territories which will result in savings in the order of 131 million kWh, 447 billion Btu and 8 million dollars.

Mumma, S.A.; Ashland, M.

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

EPRI Feedwater Heater Technology Conference Proceedings  

Science Conference Proceedings (OSTI)

This report documents the proceedings of EPRI's 2013 Feedwater Heater Technology Conference.BackgroundFeedwater heaters and associated systems cause significant loss of availability and heat rate degradation in both nuclear and fossil-fired power plants. Improving design, materials, and operation and maintenance practices can correct most losses. EPRI, utility members, equipment manufacturers, and others have worked to improve system reliability, ...

2013-09-30T23:59:59.000Z

242

Regional Variation in Residential Heat Pump Water Heater Performance in the United States  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Regional Variation in Residential Heat Pump Water Heater Performance in the US Jeff Maguire 4/30/13 Outline * Why HPWHs? * US Water Heating Market * Overview of HPWHs * Model Description * Results o HPWH Performance o Energy Savings Potential o Breakeven Cost 2 Heat Pump Water Heaters Save $300 a year over standard electric? Save $100 a year over standard gas? Heat Pump Electric Gas 3 Questions about HPWHs * Are HPWHs a good replacement for typical gas and electric storage water heaters? o In different locations across the country? o In conditioned/unconditioned space? o Source energy savings?

243

Base load fuel comsumption with radiant boiler simulation  

Science Conference Proceedings (OSTI)

The operating point of an oil fired radiant boiler, 580 Megawatt capacity, is critical in maximizing the availability, performance, reliability, and maintainability of a power producing system. Operating the unit above the design operating point causes outages to occur sooner than scheduled. When the boiler is operated below the design operating point, fuel is wasted because the quantity of fuel required to operate a radiant boiler is the same, whether the design setpoint is maintained or not. This paper demonstrates by means of simulation software that the boiler design setpoints is critical to fuel consumption and optimum output megawatts. A boiler with this capacity is used to provide a portion of the base load of an electric utility in order to sustain revenues and maintain reliable generation.

Shwehdi, M.H. (Pennsylvania State Univ., Wilkes-Barre, Lehman, PA (United States)); Hughes, C.M. (Naval Aviation Depot, NAS Jacksonville, Jacksonville, FL (United States)); Quasem, M.A. (Howard Univ. School of Business, Washington, DC (United States))

1992-12-01T23:59:59.000Z

244

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program < Back Eligibility...

245

Salem Electric - Solar Water Heater Rebate | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heater Rebate Salem Electric - Solar Water Heater Rebate Eligibility Residential Savings For Heating & Cooling Solar Water Heating Program Information Oregon Program...

246

HVAC Water Heater Field Tests Research Project | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Water Heater Field Tests Research Project HVAC Water Heater Field Tests Research Project The U.S. Department of Energy is currently conducting research into heating,...

247

Ex Parte Memorandum on Grid-Enabled Water Heaters | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

met with DOE representatives regarding water heater standards and thermal storage and demand response programs. DOE exparte memo100213 Grid-EnabledWaterHeaterAmendment...

248

Payback Analysis of Design Options for Residential Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

Payback Analysis of Design Options for Residential Water Heaters Title Payback Analysis of Design Options for Residential Water Heaters Publication Type Report LBNL Report Number...

249

TVA Partner Utilities - Energy Right Water Heater Program | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heater Program Eligibility InstallerContractor Residential Utility Savings For Appliances & Electronics Water Heating Maximum Rebate Member utility water heater rebate...

250

Space Heaters, Computers, Cell Phone Chargers: How Plugged In...  

NLE Websites -- All DOE Office Websites (Extended Search)

Space Heaters, Computers, Cell Phone Chargers: How Plugged In Are Commercial Buildings? Title Space Heaters, Computers, Cell Phone Chargers: How Plugged In Are Commercial...

251

High Performance Diesel Fueled Cabin Heater  

DOE Green Energy (OSTI)

Recent DOE-OHVT studies show that diesel emissions and fuel consumption can be greatly reduced at truck stops by switching from engine idle to auxiliary-fired heaters. Brookhaven National Laboratory (BNL) has studied high performance diesel burner designs that address the shortcomings of current low fire-rate burners. Initial test results suggest a real opportunity for the development of a truly advanced truck heating system. The BNL approach is to use a low pressure, air-atomized burner derived form burner designs used commonly in gas turbine combustors. This paper reviews the design and test results of the BNL diesel fueled cabin heater. The burner design is covered by U.S. Patent 6,102,687 and was issued to U.S. DOE on August 15, 2000.The development of several novel oil burner applications based on low-pressure air atomization is described. The atomizer used is a pre-filming, air blast nozzle of the type commonly used in gas turbine combustion. The air pressure used can b e as low as 1300 Pa and such pressure can be easily achieved with a fan. Advantages over conventional, pressure-atomized nozzles include ability to operate at low input rates without very small passages and much lower fuel pressure requirements. At very low firing rates the small passage sizes in pressure swirl nozzles lead to poor reliability and this factor has practically constrained these burners to firing rates over 14 kW. Air atomization can be used very effectively at low firing rates to overcome this concern. However, many air atomizer designs require pressures that can be achieved only with a compressor, greatly complicating the burner package and increasing cost. The work described in this paper has been aimed at the practical adaptation of low-pressure air atomization to low input oil burners. The objective of this work is the development of burners that can achieve the benefits of air atomization with air pressures practically achievable with a simple burner fan.

Butcher, Tom

2001-08-05T23:59:59.000Z

252

Subsurface connection methods for subsurface heaters  

DOE Patents (OSTI)

A system for heating a subsurface formation is described. The system includes a first elongated heater in a first opening in the formation. The first elongated heater includes an exposed metal section in a portion of the first opening. The portion is below a layer of the formation to be heated. The exposed metal section is exposed to the formation. A second elongated heater is in a second opening in the formation. The second opening connects to the first opening at or near the portion of the first opening below the layer to be heated. At least a portion of an exposed metal section of the second elongated heater is electrically coupled to at least a portion of the exposed metal section of the first elongated heater in the portion of the first opening below the layer to be heated.

Vinegar, Harold J. (Bellaire, TX); Bass, Ronald Marshall (Houston, TX); Kim, Dong Sub (Sugar Land, TX); Mason, Stanley Leroy (Allen, TX); Stegemeier, George Leo (Houston, TX); Keltner, Thomas Joseph (Spring, TX); Carl, Jr., Frederick Gordon (Houston, TX)

2010-12-28T23:59:59.000Z

253

Finite-volume model for chemical vapor infiltration incorporating radiant heat transfer. Interim report  

SciTech Connect

Most finite-volume thermal models account for the diffusion and convection of heat and may include volume heating. However, for certain simulation geometries, a large percentage of heat flux is due to thermal radiation. In this paper a finite-volume computational procedure for the simulation of heat transfer by conduction, convection and radiation in three dimensional complex enclosures is developed. The radiant heat transfer is included as a source term in each volume element which is derived by Monte Carlo ray tracing from all possible radiating and absorbing faces. The importance of radiative heat transfer is illustrated in the modeling of chemical vapor infiltration (CVI) of tubes. The temperature profile through the tube preform matches experimental measurements only when radiation is included. An alternative, empirical approach using an {open_quotes}effective{close_quotes} thermal conductivity for the gas space can match the initial temperature profile but does not match temperature changes that occur during preform densification.

Smith, A.W.; Starr, T.L. [Georgia Institute of Technology, Atlanta, GA (United States). School of Materials Science and Engineering

1995-05-01T23:59:59.000Z

254

Tankless or Demand-Type Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters May 2, 2012 - 6:47pm Addthis Diagram of a tankless water heater. Diagram of a tankless water heater. How does it work? Tankless water heaters deliver hot water as it is needed, eliminating the need for storage tanks. Tankless water heaters, also known as demand-type or instantaneous water heaters, provide hot water only as it is needed. They don't produce the standby energy losses associated with storage water heaters, which can save you money. Here you'll find basic information about how they work, whether a tankless water heater might be right for your home, and what criteria to use when selecting the right model. Check out the Energy Saver 101: Water Heating infographic to learn if a tankless water heater is right for you.

255

Southwest Gas Corporation - Commercial High-Efficiency Equipment...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

who purchase energy efficient natural gas equipment. Eligible equipment includes natural gas storage and tankless water heaters, boiler equipment, griddles, fryers, conveyor ovens,...

256

Managing Feedwater Heater Shell Thinning  

SciTech Connect

Thinning of feedwater heater (FWH) shells has become an important issue throughout the U.S. nuclear industry. The thinning occurs primarily in the vicinity of the extraction steam and drain inlet nozzles where two-phase steam/water mixtures enter the heater. The thinning can be general wall thinning over a large area or highly localized thinning in a limited area. Eventually, shell repairs become necessary to ensure integrity of the pressure boundary and personnel safety, and to restore compliance with the ASME pressure vessel code. Ideally, long-term monitoring of the thickness of FWH shells would allow for timely repairs before the wall thickness decreases below the ASME Code minimum wall thickness. However, since most plants did not start inspecting FWH shells until recently, the initial inspection may find shells that are thinned to near or below the ASME Code minimum wall thickness. Because the cost and manpower requirements for shell repairs can be significant, it is imperative that shell repairs provide a long-term solution and that they be implemented as a planned outage evolution. Accordingly, the approach to managing FWH shell thinning must provide sufficient advance warning of the need for repairs while ensuring safe operation until the permanent repair can be implemented. The approach outlined in this paper does both. Establish acceptance criteria to ensure safe, interim operation with thinned shells until a permanent repair can be implemented. Develop contingency plans for interim repairs should the inspections identify thinning below the interim acceptance criteria. Inspect FWH shells during a refueling outage or possibly during planned system outages or power reductions. If necessary, perform interim repairs to ensure safe operation until the next refueling outage. Develop and implement permanent repairs that will prevent shell thinning. (authors)

Simons, John W.; Keating, Robert B. [MPR Associates Inc., 140 Mustang Circle, Simpsonville, SC 29681 (United States)

2002-07-01T23:59:59.000Z

257

Particulate matter sensor with a heater  

DOE Patents (OSTI)

An apparatus to detect particulate matter. The apparatus includes a sensor electrode, a shroud, and a heater. The electrode measures a chemical composition within an exhaust stream. The shroud surrounds at least a portion of the sensor electrode, exclusive of a distal end of the sensor electrode exposed to the exhaust stream. The shroud defines an air gap between the sensor electrode and the shroud and an opening toward the distal end of the sensor electrode. The heater is mounted relative to the sensor electrode. The heater burns off particulate matter in the air gap between the sensor electrode and the shroud.

Hall, Matthew (Austin, TX)

2011-08-16T23:59:59.000Z

258

Comparison of Zone Cooling Load for Radiant and All-Air Conditioning Systems  

E-Print Network (OSTI)

Load for Radiant and Air Conditioning Systems. ProceedingsRefrigerating and Air Conditioning Engineers Inc. Babiak,of European Heating ahd Air-Conditioning Associations. CEN (

Feng, Jingjuan; Schiavon, Stefano; Bauman, Fred

2012-01-01T23:59:59.000Z

259

Multifamily Heat Pump Water Heater Evaluation  

SciTech Connect

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

Hoeschele, M.; Weitzel, E.

2013-11-01T23:59:59.000Z

260

High Efficiency R-744 Commercial Heat Pump Water Heaters  

SciTech Connect

The project investigated the development and improvement process of a R744 (CO2) commercial heat pump water heater (HPWH) package of approximately 35 kW. The improvement process covered all main components of the system. More specific the heat exchangers (Internal heat exchanger, Evaporator, Gas cooler) as well as the expansion device and the compressor were investigated. In addition, a comparison to a commercially available baseline R134a unit of the same capacity and footprint was made in order to compare performance as well as package size reduction potential.

Elbel, Dr. Stefan W.; Petersen, Michael

2013-04-25T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Zoned electrical heater arranged in spaced relationship from particulate filter  

DOE Patents (OSTI)

A system comprises a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas and a downstream end. A zoned heater is arranged spaced from the upstream end and comprises N zones, where N is an integer greater than one, wherein each of the N zones comprises M sub-zones, where M is an integer greater than one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates non-selected ones of the N zones.

Gonze, Eugene V [Pinckney, MI

2011-11-15T23:59:59.000Z

262

Selecting a New Water Heater | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Selecting a New Water Heater Selecting a New Water Heater Selecting a New Water Heater August 29, 2012 - 7:30pm Addthis Water heater testing facility at Oak Ridge National Laboratory. Water heater testing facility at Oak Ridge National Laboratory. When selecting a new water heater for your home, choose a water heating system that will not only provide enough hot water but also that will do so energy efficiently, saving you money. This includes considering the different types of water heaters available and determining the right size and fuel source for your home. Check out the Energy Saver 101: Water Heating infographic to learn more about the different types of water heaters and how to select the right model for your home. Types of Water Heaters It's a good idea to know the different types of water heaters available

263

Sizing a New Water Heater | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sizing a New Water Heater Sizing a New Water Heater Sizing a New Water Heater May 29, 2012 - 7:16pm Addthis Is your water heater the right size for you house? | Photo credit ENERGY STAR¼ Is your water heater the right size for you house? | Photo credit ENERGY STAR¼ A properly sized water heater will meet your household's hot water needs while operating more efficiently. Therefore, before purchasing a water heater, make sure it's the correct size. Here you'll find information about how to size these systems: Tankless or demand-type water heaters Solar water heating system Storage and heat pump (with tank) water heaters. For sizing combination water and space heating systems -- including some heat pump systems, and tankless coil and indirect water heaters -- consult a qualified contractor.

264

Solar Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heaters Solar Water Heaters Solar Water Heaters May 7, 2012 - 9:52am Addthis Solar water heaters -- also called solar domestic hot water systems -- can be a cost-effective way to generate hot water for your home. They can be used in any climate, and the fuel they use -- sunshine -- is free. How They Work Solar water heating systems include storage tanks and solar collectors. There are two types of solar water heating systems: active, which have circulating pumps and controls, and passive, which don't. Active Solar Water Heating Systems There are two types of active solar water heating systems: Direct circulation systems Pumps circulate household water through the collectors and into the home. They work well in climates where it rarely freezes. Indirect circulation systems

265

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

heaters heaters Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the flat-plate collector. Solar water heaters use the sun to heat either water

266

Heat Pump Water Heaters Demonstration Project  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pump Water Heaters Heat Pump Water Heaters Demonstration Project Building America Stakeholder Meeting Ron Domitrovic Ammi Amarnath 3/1/2012 Austin, TX 2 © 2011 Electric Power Research Institute, Inc. All rights reserved. HPWH Field Demonstration: Research Objectives * Assess heat pump water heater technology by measuring efficiency. * Provide credible data on the performance and reliability of heat pump water heaters. * Assess user satisfaction in a residential setting. 3 © 2011 Electric Power Research Institute, Inc. All rights reserved. Demonstration Host Utilities Target: 40 Units per Utility Installed and Potential Sites by Climate Zone Source: Department of Energy (DOE), Building America climate regions 4 © 2011 Electric Power Research Institute, Inc. All rights reserved. Installation Locations-Southern Company Region

267

Tankless Water Heaters: Do They Really Work?  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless Water Heaters: Do They Tankless Water Heaters: Do They Really Work? Center for Energy and Environment, NorthernSTAR, Ben Schoenbauer Context * Domestic Water Heating is the next big residential energy in efficiency. - Space heating loads are being reduced - Largest peak load in almost all homes is water heating - Annual water heating load is larger than annual space heating load in many homes - Most DHW equipment is inefficiency 50-60% Technical Approach * TWHs and condensing TWHs have significant energy savings potential - Do these ratings relate to real world performance? - How do TWHs compare to standard water heaters? - What performance/install issues do they have? * 10 home 26 water heater alternating mode field study was conducted Recommended Guidance * In situations where economics are

268

Tankless Coil and Indirect Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

Tankless coil and indirect water heaters use a home or building's space heating system to heat water as part of an integrated or combination water and space heating system.

269

Heater head for a Stirling engine  

Science Conference Proceedings (OSTI)

A heater head is described for a compound Stirling engine modules, each including a displacer cylinder coaxially aligned with the displacer cylinder of the other of the engine modules, a displacer piston mounted for reciprocation in the displacer cylinder.

Darooka, D.K.

1988-09-06T23:59:59.000Z

270

Diesel particulate filter with zoned resistive heater  

Science Conference Proceedings (OSTI)

A diesel particulate filter assembly comprises a diesel particulate filter (DPF) and a heater assembly. The DPF filters a particulate from exhaust produced by an engine. The heater assembly has a first metallic layer that is applied to the DPF, a resistive layer that is applied to the first metallic layer, and a second metallic layer that is applied to the resistive layer. The second metallic layer is etched to form a plurality of zones.

Gonze, Eugene V [Pinckney, MI

2011-03-08T23:59:59.000Z

271

Strategy Guideline: Proper Water Heater Selection  

Science Conference Proceedings (OSTI)

This strategy guideline provides step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads. These procedures, developed both for individual water heater applications (both single and multi-family) and multifamily central systems, provide users with projections on operating cost savings over a 10-year time horizon for retrofit applications and on a cash flow basis for new construction.

Hoeschele, M.; Springer, D.; German, A.; Staller, J.; Zhang, Y.

2012-08-01T23:59:59.000Z

272

Heat Pump Water Heaters for Commercial Buildings  

Science Conference Proceedings (OSTI)

This technical update from the Electric Power Research Institute (EPRI) reviews the technology of heat pump water heaters (HPWHs) for commercial building applications. The report discusses the technical and conceptual background of heat pump water heaters, laboratory testing as performed at EPRI's laboratory, and implications of the test results. It provides analysis of the climactic applicability, financial scenarios, the air-cooling benefit or detriment of HPWH technology.

2011-12-22T23:59:59.000Z

273

Cooling-energy measurements of unoccupied single-family houses with attics containing radiant barriers  

Science Conference Proceedings (OSTI)

Tests were conducted by Oak Ridge National Laboratory (ORNL) to determine the magnitude of the energy savings brought about by installing radiant barriers in the attics of single-family houses. The radiant barrier used for this test is a product with two reflective aluminum surfaces on a kraft paper base. The purpose of the radiant barrier is to reduce the radiant heat transfer component impinging on the fiberglass attic insulation. The radiant barrier works as a system in conjunction with an air space and can theoretically block up to 95% of far-infrared radiation heat transfer. The experiment was conducted in three unoccupied research houses that are operated by ORNL. Two variations on the installation of radiant barriers were studied. One house was used as the control house (no barrier was installed), while the other two were used to test the two different methods for installing the radiant barriers. In one house the barrier was laid on top of the attic fiberglass batt insulation, and in the other house, the barrier was attached to the underside of the roof trusses. The attics of all three houses were insulated with kraft-paper-faced R-19 fiberglass batt insulation. The results showed a savings in the cooling loads of 21% when the radiant barrier was laid on top of the attic fiberglass insulation and 13% with the radiant barrier attached to the underside of the roof trusses. The savings in electrical consumption were 17% and 9%, respectively. The electrical consumption data and the cooling load data indicate that the most effective way of installing the foil is to lay it on top of the fiberglass insulation. The radiant barriers reduced the measured peak ceiling heat fluxes by 39% for the case where the barrier was laid on top of the fiberglass insulation. The radiant barrier reduced the integrated heat flows from the attic to the house by approximately 30 to 35% over a 7-day time period.

Levins, W.P.; Karnitz, M.A.

1986-07-01T23:59:59.000Z

274

Radiant Energy Power Source for Jet Aircraft. Final performance report  

DOE Green Energy (OSTI)

This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.

Doellner, O.L.

1992-02-01T23:59:59.000Z

275

Minnesota Energy Resources (Gas) - Residential Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

natural gas equipment and set-back thermostats. Rebates are available for furnaces, boilers, integrated space and water heating systems, programmable thermostats, water heaters...

276

Southwest Gas Corporation - Commercial Energy Efficient Equipment...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

offers rebates to commercial customers in Nevada who purchase energy efficient natural gas equipment. Eligible equipment includes clothes washers, storage water heaters, tankless...

277

Southwest Gas Corporation - Southwest Gas Corporation - Residential...  

Open Energy Info (EERE)

Insulation: 0.15sq ft Floor Insulation: 0.30sq ft Builders Energy Star Certified Home: 450 Natural Gas Tankless Water Heater: 450 Attic Insulation: 0.15sq ft Equipment...

278

Selecting a New Water Heater You have a lot to consider when selecting a  

E-Print Network (OSTI)

the water heater's annual operation costs but also its size and energy efficiency. Natural gas, oil if they offer off- peak electricity rates. If available, heating your water during off-peak hours will save you use. Estimating your peak hot water usage will help you identify an appropriate tank for your

279

Cooling season energy measurements of dust and ventilation effects on radiant barriers  

Science Conference Proceedings (OSTI)

Cooling season tests were conducted in three unoccupied ranch-style houses in Karns, Tennessee, to determine the effects on attic radiant barrier performance incurred by changes in attic ventilation area ratio, attic ventilation type, and the buildup of dust on horizontal radiant barriers. All three houses had R-19 fiberglass batt insulation in their attics. Horizontal radiant barriers were artificially dusted and the dusted barriers showed measurable performance degradations, although the dusted barriers were still superior to no radiant barriers. Dust loadings of 0.34 and 0.74 mg/cm{sup 2} reduced a clean radiant barrier surface emissivity of 0.055 to 0.125 and 0.185, respectively. Total house cooling load increases amounted to 2.3 and 8.4% compared to house loads with clean horizontal barriers, respectively. When compared to R-19 with no horizontal radiant barrier conditions, the dusted horizontal radiant barriers reduced cooling loads by about 7%. Testing showed that increasing the attic ventilation area ratio from the minimum recommended of 1/300 (1 ft{sup 2} of effective ventilation area per 300 ft{sup 2} of attic area) to 1/150 had little if any effect on the house cooling load with either truss or horizontal barriers present in the attics. Radiant barriers, however, still reduced the house cooling load. 18 refs., 17 figs., 26 tabs.

Levins, W.P.; Karnitz, M.A. (Oak Ridge National Lab., TN (USA)); Hall, J.A. (Tennessee Valley Authority, Chattanooga, TN (USA))

1990-03-01T23:59:59.000Z

280

Heating energy measurements of unoccupied single-family houses with attics containing radiant barriers  

Science Conference Proceedings (OSTI)

Tests were conducted by Oak Ridge National Laboratory (ORNL) to determine the magnitude of the heating energy savings achieved by installing attic radiant barriers. The radiant barriers used for the test consist of a material with two reflective aluminum surfaces on a kraft paper base. The experiment was conducted in three unoccupied research houses operated by ORNL. Two variations in the installation of radiant barriers were studied. One house was used as the control house (no barrier was installed), while the other two were used to test the two methods for installing the radiant barriers. In one house, the radiant barrier was laid on top of the attic fiberglass batt insulation, and in the other house, the barrier was attached to the underside of the roof trusses. The attics of all three houses were insulated with a kraft-paper-faced R-19 fiberglass batt insulation. The winter test with the radiant barrier showed that the horizontal barrier was able to save space-heating electical energy in both the resistance and heat pump modes amounting to 10.1% and 8.5%, respectively. The roof truss radiant barrier increased consumption by 2.6% in the resistance mode and 4.0% in the heat pump mode. The horizontal orientation of the radiant barrier is the more energy-effective method of installation.

Levins, W.P.; Karnitz, M.A.

1987-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Analysis of Annual Thermal and Moisture Performance of Radiant Barrier Systems  

Science Conference Proceedings (OSTI)

A detailed thermal energy analysis model helps identify locations where radiant barriers are cost-effective while analyzing moisture performance to predict potential problem areas. The model described in this report estimates annual energy savings and moisture accumulation rates from horizontal radiant barrier applications in a variety of climates.

1991-09-03T23:59:59.000Z

282

Questar Gas - Residential Energy Efficiency Rebate Programs (Idaho) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Programs (Idaho) Programs (Idaho) Questar Gas - Residential Energy Efficiency Rebate Programs (Idaho) < Back Eligibility Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Appliances & Electronics Water Heating Windows, Doors, & Skylights Maximum Rebate Limit of one rebate per appliance type Duct Sealing/Insulation: $450 (Single Family); $250 (Multifamily) Program Info State Idaho Program Type Utility Rebate Program Rebate Amount Furnace: $200-$400 Solar Assisted Water Heater: $750 Storage Water Heater: $50-$100 Gas Condensing/Hybrid Water Heater: $350 Tankless Water Heater: $300-$350 Boiler: $400 - $600 Solar Hot Water Heater: $750 Gas Clothes Washer: $50

283

Thermal radiant exitance model performance: Soils and forests  

DOE Green Energy (OSTI)

Models of surface temperatures of two land surface types based on their energy budgets were developed to simulate the effects of environmental factors on thermal radiant exitance. The performance of these models is examined in detail. One model solves the non-linear differential equation for heat diffusion in solids using a set of submodels for surface energy budget components. The model performance is examined under three desert conditions thought to be a strong test of the submodels. The accuracy of the temperature predictions and submodels is described. The accuracy of the model is generally good but some discrepancies between some of the submodels and measurements are noted. The sensitivity of the submodels is examined and is seen to be strongly controlled by interaction and feedback among energy components that are a function of surface temperature. The second model simulates vegetation canopies with detailed effects of surface geometry on radiant transfer in the canopy. Foliage solar absorption coefficients are calculated using a radiosity approach for a three layer canopy and long wave fluxes are modeled using a view factor matrix. Sensible and latent heat transfer through the canopy are also simulated using, nearby meteorological data but heat storage in the canopy is not included. Simulations for a coniferous forest canopy are presented and the sensitivity of the model to environmental inputs is discussed.

Balick, L.K. [EG& G Energy Measurements Inc., Las Vegas, NV (United States); Smith, J.A. [NASA/Goddard Space Flight Center, Greenbelt, MD (United States). Lab. for Terrestrial Physics

1995-12-31T23:59:59.000Z

284

Radiant heat transfer from storage casks to the environment  

SciTech Connect

A spent fuel storage cask must efficiently transfer the heat released by the fuel assemblies through the cask walls to the environment. This heat must be transferred through passive means, limiting the energy transfer mechanisms from the cask to natural convection and radiation heat transfer.. Natural convection is essentially independent of the characteristics of the array of casks, provided there is space between casks to permit a convection loop. Radiation heat transfer, however, depends on the geometric arrangement of the array of casks because the peripheral casks will shadow the interior casks and restrict radiant heat transfer from all casks to the environment. The shadowing of one cask by its neighbors is determined by a view factor that represents the fraction of radiant energy that leaves the surface of a cask and reaches the environment. This paper addresses the evaluation of the view factor between a centrally located spent fuel storage cask and the environment. By combining analytic expressions for the view factor of (1) infinitely long cylinders and (2) finite cylinders with a length-to-diameter ratio of 2 to represent spent fuel storage casks, the view factor can be evaluated for any practical array of spent fuel storage casks.

Carlson, R W; Hovingh, J; Thomas, G R

1999-05-10T23:59:59.000Z

285

Analysis of annual thermal and moisture performance of radiant barrier systems  

Science Conference Proceedings (OSTI)

This report summarizes a project to model the annual thermal and moisture performance of radiant barrier systems installed in residential attics. A previously developed model for the thermal performance of attics with radiant barriers was modified to allow estimates of moisture condensation on the underside of radiant barriers that are laid directly on top of existing attic insulation. The model was partially validated by comparing its predictions of ceiling heat flows and moisture condensation with data and visual observations made during a field experiment with full-size houses near Knoxville, Tennessee. Since the model predictions were found to be in reasonable agreement with the experimental data, the models were used to estimate annual energy savings and moisture accumulation rates for a wide variety of climatic conditions. The models results have been used to identify locations where radiant barriers are cost effective and also where radiant barriers have potential for causing moisture problems. 58 refs., 20 figs., 32 tabs.

Wilkes, K.E.

1991-04-01T23:59:59.000Z

286

Thermal performance of clean horizontal radiant barriers under winter conditions: Laboratory measurements and mathematical modeling  

Science Conference Proceedings (OSTI)

Several field experiments have been performed on attic radiant barriers under winter conditions; however, most of them have been confined to the fairly mild climates of Florida, Oklahoma, and Tennessee. Only one field experiment in a very cold climate (Canada) has been performed. In addition, no previous laboratory experiments under winter conditions have been performed on an attic both with and without a radiant barrier. This paper presents the results of laboratory measurements of the thermal performance of clean horizontal radiant barriers in a simulated residential attic module under nighttime or low solar gain daytime winter conditions. Comparing tests under the same conditions with and without a radiant barrier shows that the addition of a clean horizontal radiant barrier to insulation at the R-22 to R-25 level decreases the ceiling heat flow by 6 to 8%. The experimental results were found to be in very good agreement with predictions made with a mathematical model for the thermal performance of attics.

Wilkes, K.E.; Childs, P.W.

1992-01-01T23:59:59.000Z

287

Analysis of annual thermal and moisture performance of radiant barrier systems  

Science Conference Proceedings (OSTI)

This report summarizes a project to model the annual thermal and moisture performance of radiant barrier systems installed in residential attics. A previously developed model for the thermal performance of attics with radiant barriers was modified to allow estimates of moisture condensation on the underside of radiant barriers that are laid directly on top of existing attic insulation. The model was partially validated by comparing its predictions of ceiling heat flows and moisture condensation with data and visual observations made during a field experiment with full-size houses near Knoxville, Tennessee. Since the model predictions were found to be in reasonable agreement with the experimental data, the models were used to estimate annual energy savings and moisture accumulation rates for a wide variety of climatic conditions. The model results have been used to identify locations where radiant barriers are cost effective and also where radiant barriers have potential for causing moisture problems. 58 refs., 20 figs., 32 tabs.

Wilkes, K.E. (Oak Ridge National Lab., TN (United States))

1991-08-01T23:59:59.000Z

288

Thermal performance of clean horizontal radiant barriers under winter conditions: Laboratory measurements and mathematical modeling  

Science Conference Proceedings (OSTI)

Several field experiments have been performed on attic radiant barriers under winter conditions; however, most of them have been confined to the fairly mild climates of Florida, Oklahoma, and Tennessee. Only one field experiment in a very cold climate (Canada) has been performed. In addition, no previous laboratory experiments under winter conditions have been performed on an attic both with and without a radiant barrier. This paper presents the results of laboratory measurements of the thermal performance of clean horizontal radiant barriers in a simulated residential attic module under nighttime or low solar gain daytime winter conditions. Comparing tests under the same conditions with and without a radiant barrier shows that the addition of a clean horizontal radiant barrier to insulation at the R-22 to R-25 level decreases the ceiling heat flow by 6 to 8%. The experimental results were found to be in very good agreement with predictions made with a mathematical model for the thermal performance of attics.

Wilkes, K.E.; Childs, P.W.

1992-08-01T23:59:59.000Z

289

Field Monitoring of a Geothermal Heat Pump Water Heater: Unicoi County High School, Erwin, Tennessee  

Science Conference Proceedings (OSTI)

A geothermal heat pump water heater (HPWH) system -- installed to preheat water entering a 250-gallon gas-fired water heater (GWH) at a Tennessee high school -- reduced water-heating costs by 34 percent per year, compared to the base case GWH system. This report provides results from field monitoring of the geothermal HPWH system, tested in three distinct operating modes for five months. The program goal was to assess the energy and economic benefits of the GWH system with and without the geothermal HPWH...

2003-10-15T23:59:59.000Z

290

Tankless Coil and Indirect Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Coil and Indirect Water Heater Basics Coil and Indirect Water Heater Basics Tankless Coil and Indirect Water Heater Basics August 19, 2013 - 3:03pm Addthis Illustration of a tankless coil water heater. The heater is box-shaped, and has two pipes sticking out one end: one a cold water inlet, and one a hot water outlet. These pipes lead into the heater to a cylindrical coil called a heat exchanger. Long tubes surrounding the heat exchanger are labeled the heated water jacket. At the bottom of the box is a row of small flames, called the boiler heat source. Tankless coil and indirect water heaters use a home or building's space heating system to heat water as part of an integrated or combination water and space heating system. How Tankless Coil and Indirect Water Heaters Work A tankless coil water heater uses a heating coil or heat exchanger

291

Tankless Coil and Indirect Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters May 16, 2013 - 7:21pm Addthis An indirect water heater. An indirect water heater. How does it work? Tankless coil and indirect water heaters use your home's heating system to heat water. Tankless coil and indirect water heaters use a home's space heating system to heat water. They're part of what's called integrated or combination water and space heating systems. How They Work A tankless coil water heater provides hot water on demand without a tank. When a hot water faucet is turned on, water is heated as it flows through a heating coil or heat exchanger installed in a main furnace or boiler. Tankless coil water heaters are most efficient during cold months when the heating system is used regularly but can be an inefficient choice for many

292

MHD air heater development technology. Report for the period October 1978-December 1978  

DOE Green Energy (OSTI)

During the period covered by this report, work was done on all three tasks and is summarized as follows: Under Task 1 (design studies) the influence of heater system layout, duct dimensions, and heater sequencing on flow distribution was studied further. One result was that localizing the bulk of the pressure drop in the heaters tends to minimize heater-to-heater flow differences. The task of integrating the temperature and pressure solvers was pursued further. An analysis of current flow back up the air duct from the combustor was done. Results showed that the voltage gradient and power loss back up the air duct depend on the ratio of electrical conductivities of air and duct wall insulation. Under Task 2 (design support tests) Heat 201 was completed and much of the construction on the valve test rig was completed. Heat 201 was run with a Corhart X-317 (fusion cast magnesia-35% alumina, hereafter referred to as Corhart X-317 as this trade name designates not only composition, but microstructure, impurity level and manufacturer's process) matrix in the rig. Matrix Test 7 (Heat 201) ran for over four hundred hours but was terminated early because of a restriction in the bed. This was caused by failure of the insulating lining in the hot gas duct between the burner and the matrix. This liner of magnesia-chrome bricks (RFG) had been used in earlier tests. Reactions with seed/slag occurred and the resulting high viscosity slag partially plugged the bed. Under Task 3 (preliminary design of 5 MW heater) a topical report describing the design of the 5 MW test heater system was prepared. At the end of this reporting period it was being reviewed.

None

1979-04-01T23:59:59.000Z

293

Dust and ventilation effects on radiant barriers: Cooling season energy measurements  

Science Conference Proceedings (OSTI)

Cooling season tests were conducted in three unoccupied ranch-style houses in Karns, Tennessee, to determine the effects on attic radiant barrier performance incurred by changes in attic ventilation area ratio, attic ventilation type, and the buildup of dust on horizontal radiant barriers. All three houses had R-19 fiberglass batt insulation in their attics. Horizontal radiant barriers were artificially dusted and the dusted barriers showed measurable performance degradations, although the dusted barriers were still superior to no radiant barriers. Dust loadings of 0.34 and 0.74 mg/cm{sup 2} reduced a clean radiant barrier surface emissivity of 0.055 to 0.125 and 0.185, respectively. Total house cooling load increases amounted to 2.3 and 8.4% compared to house loads with clean horizontal barriers, respectively. When compared to R-19 with no horizontal radiant barrier conditions, the dusted horizontal radiant barriers reduced cooling loads by about 7%. Testing showed that increasing the attic ventilation area ratio from the minimum recommended of 1/300 to 1/150 had little if any effect on the house cooling load with either truss or horizontal barriers present in the attics. Radiant barriers, however, still reduced the house cooling load. There was essentially no difference in house cooling load reduction between either ridge/soffit or gable/soffit vent type with a truss radiant barrier, as both reduced cooling loads by about 8% when compared to no radiant barrier conditions. The attic-ventilation-type testing was done with a ventilation area ratio of 1/150.

Levins, W.P.; Karnitz, M.A. (Oak Ridge National Lab., TN (USA)); Hall, J.A. (Tennessee Valley Authority, Knoxville, TN (USA))

1990-05-01T23:59:59.000Z

294

Experiment System Analysis of an Indirect Expansion Solar Assisted Water Source Heat Pump Radiant Floor Heating System  

Science Conference Proceedings (OSTI)

A solar assisted water source heat pump for Radiant Floor Heating (SWHP-RFH) experimental system with heat pipe vacuum tube solar collector as heating source and radiant floor as terminal device is proposed in the paper. The Mathematics Model of dynamic ... Keywords: solar energy, water source heat pump, radiant floor heating systems, system dynamic COP

Qu Shilin; Ma Fei; Liu Li; Yue Jie

2009-10-01T23:59:59.000Z

295

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

water heaters water heaters (Redirected from - Solar Hot Water) Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the

296

Solar Water Heater Rebate | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heater Rebate Solar Water Heater Rebate Solar Water Heater Rebate < Back Eligibility Commercial Fed. Government Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Hawaii Program Type State Rebate Program Rebate Amount Residential Solar Water Heating: $1,000 upfront, or Residential Solar Water Heating Interest Loan Buy-Down: $1,000 Residential Solar Attic Fans: $50 Commercial: $250 per 12,000 Btu/hr derated capacity Provider Hawaii Energy Hawaii Energy, a third-party administered public benefits fund, provides incentives for energy efficiency and conservation to customers of the Hawaiian Electric Company (HECO) and its subsidiaries, Maui Electric Company (MECO) and Hawaii Electric Light Company (HELCO). This incentive is available for installations on the islands of Oahu, Hawaii, Maui, Lanai and

297

Radiant energy receiver having improved coolant flow control means  

DOE Patents (OSTI)

An improved coolant flow control for use in radiant energy receivers of the type having parallel flow paths is disclosed. A coolant performs as a temperature dependent valve means, increasing flow in the warmer flow paths of the receiver, and impeding flow in the cooler paths of the receiver. The coolant has a negative temperature coefficient of viscosity which is high enough such that only an insignificant flow through the receiver is experienced at the minimum operating temperature of the receiver, and such that a maximum flow is experienced at the maximum operating temperature of the receiver. The valving is accomplished by changes in viscosity of the coolant in response to the coolant being heated and cooled. No remotely operated valves, comparators or the like are needed.

Hinterberger, H.

1980-10-29T23:59:59.000Z

298

Indoor Humidity Analysis of an Integrated Radiant Cooling and Desiccant Ventilation System  

E-Print Network (OSTI)

Radiant cooling is credited with improving energy efficiency and enhancing the comfort level as an alternative method of space cooling in mild and dry climates, according to recent research. Since radiant cooling panels lack the capability to remove latent heat, they normally are used in conjunction with an independent ventilation system, which is capable of decoupling the space sensible and latent loads. Condensation concerns limit the application of radiant cooling. This paper studies the dehumidification processes of solid desiccant systems and investigates the factors that affect the humidity levels of a radiantly cooled space. Hourly indoor humidity is simulated at eight different operating conditions in a radiantly cooled test-bed office. The simulation results show that infiltration and ventilation flow rates are the main factors affecting indoor humidity level and energy consumption in a radiantly cooled space with relatively constant occupancy. It is found that condensation is hard to control in a leaky office operated with the required ventilation rate. Slightly pressurizing the space is recommended for radiant cooling. The energy consumption simulation shows that a passive desiccant wheel can recover about 50% of the ventilation load.

Gong, X.; Claridge, D. E.

2006-01-01T23:59:59.000Z

299

Energy measurements of attic radiant barriers installed in single-family houses  

Science Conference Proceedings (OSTI)

Testing was conducted by the Oak Ridge National Laboratory to determine the energy savings attributable to radiant barriers installed in attics of unoccupied single-family houses. Three levels of fiberglass attic insulation (R-11 ,R-19, and R-30) were tested with two types of barrier installation (horizontal and truss). The results showed that horizontally installed radiant barriers were more effective than truss barriers in reducing heating and cooling loads. Measured cooling load reductions ranged form 0 to 22% (compared to same attic insulation insulation R-value with no radiant barrier) and heating load changes from /plus/4% to /minus/10% were measured (compared to same attic insulation R-value with no radiant barrier). Radiant barriers appeared to decrease the heating and cooling loads more when lesser amounts of insulation (R-11 and R-19) were present in an attic. Minimal changes were measured when R-30 was present in an attic. Long-term effects of dust on the performance of radiant barriers as well as the effects of moisture condensing on the surface of a radiant barrier during cold winter temperatures remain unanswered.

Levins, W.P.; Karnitz, M.A.

1988-07-01T23:59:59.000Z

300

Cooling season energy measurements of dust and ventilation effects on radiant barriers  

Science Conference Proceedings (OSTI)

Cooling season tests were conducted in three unoccupied ranch-style houses in Karns, Tennessee, to determine the effects on attic radiant barrier performance incurred by changes in attic ventilation area ratio, attic ventilation type, and the buildup of dust on horizontal radiant barriers. All three houses had R-19 fiberglass batt insulation in their attics. Horizontal radiant barriers were artificially dusted and the dusted barriers showed measurable performance degradations, although the dusted barriers were still superior to no radiant barriers. Dust loadings of 0.34 and 0.74 mg/cm{sup 2} reduced a clean radiant barrier surface emissivity of 0.055 to 0.125 and 0.185, respectively. Total house cooling load increases amounted to 2.3 and 8.4% compared to house loads with clean horizontal barriers, respectively. When compared to R-19 with no horizontal radiant barrier conditions, the dusted horizontal radiant barriers reduced cooling loads by about 7%. 18 refs., 18 figs., 30 tabs.

Levins, W.P.; Karnitz, M.A. (Oak Ridge National Lab., TN (USA)); Hall, J.A. (Tennessee Valley Authority, Knoxville, TN (USA))

1990-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Heat pump water heaters. Final report  

SciTech Connect

A survey of the eleven manufacturers of heat pump water heaters (HPWHs) in the United States is presented. Product characteristics and application guidelines, including economic comparisons to other means of water heating, are summarized. A survey of forty-five utilities, identified as having conducted field tests of HPWHs, is also presented. Based on the experiences of these utilities, experimental designs, instrumentation schemes, and data reduction methods are recommended. A brief assessment of utility load profile impacts illustrates that HPWHs can provide peak load reductions compared to electric resistance water heaters. Specific recommendations are made for further research and development of HPWHs.

Dobyns, J.E.; Blatt, M.H.

1984-05-01T23:59:59.000Z

302

Building Technologies Office: HVAC and Water Heater Field Tests Research  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC and Water Heater HVAC and Water Heater Field Tests Research Project to someone by E-mail Share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Facebook Tweet about Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Twitter Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Google Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Delicious Rank Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Digg Find More places to share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research

303

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

heater analysis model (WHAM) and a hot water draw model,heaters is calculated using WHAM, which accounts for a rangeTo account for this factor, WHAM is expanded to include the

Franco, Victor

2011-01-01T23:59:59.000Z

304

ENERGY STAR Residential Water Heaters to Save Americans Up to...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ENERGY STAR Residential Water Heaters to Save Americans Up to 823 Million in the Next Five Years ENERGY STAR Residential Water Heaters to Save Americans Up to 823 Million in the...

305

TVA Partner Utilities- Energy Right Water Heater Program  

Energy.gov (U.S. Department of Energy (DOE))

The TVA energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local power companies for each...

306

Buildings Energy Data Book: 5.4 Water Heaters  

Buildings Energy Data Book (EERE)

3 Water Heater Manufacturer Market Shares 2006 2008 A.O. SmithState Industries 23% 46% Rheem Manufacturing 37% 37% Bradford-White 14% 13% American Water Heater 14% (1) Others 12%...

307

System design description for the HMT Rotation Motor Heater System  

SciTech Connect

This document is the design description for the Rotation Motor Heater System on waste tank 241-SY-101. The description includes the certified vendor (CV) file number, operators instructions, and heater sizing calculations.

Vargo, G.F. Jr.

1995-05-18T23:59:59.000Z

308

Effect of a Radiant Panel Cooling System on Indoor Air Quality of a Conditioned Space  

E-Print Network (OSTI)

This paper discusses the effect of a radiant cooling panel system on an indoor air quality (IAQ) of a conditioned space. In this study, ceiling radiant cooling panel, mechanical ventilation with fan coil unit (FCU) and 100% fresh air are used. Temperature sensors are located at different locations inside the conditioned space in order to sense dry bulb temperatures, relative humidity to compare it with standard ASHRAE comfort values. The present investigation indicates that the radiant cooling system not only improves the indoor air quality but also reduces the building energy consumption in the conditioned space.

Mohamed, E.; Abdalla, K. N.

2010-01-01T23:59:59.000Z

309

NREL Evaluates Performance of Heat Pump Water Heaters (Fact Sheet)  

SciTech Connect

NREL evaluates energy savings potential of heat pump water heaters in homes throughout all U.S. climate zones.

Not Available

2012-02-01T23:59:59.000Z

310

Questar Gas - Home Builder Gas Appliance Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Questar Gas - Home Builder Gas Appliance Rebate Program Questar Gas - Home Builder Gas Appliance Rebate Program Questar Gas - Home Builder Gas Appliance Rebate Program < Back Eligibility Construction Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Construction Commercial Weatherization Design & Remodeling Appliances & Electronics Water Heating Program Info State Utah Program Type Utility Rebate Program Rebate Amount Exterior Wall Insulation: $350 (single family), $150 (multifamily) Windows: $2.50/sq. ft. Gas Furnace: $200 - $400 Gas Storage Water Heater: $50-$100 Gas Condensing Water Heater: $350 Gas Boiler: $400 -$600 Tankless Gas Water Heater: $350 Single Family Homes (New Construction): $50 - $500 Multifamily Homes (New Construction): $50 - $300/unit

311

Tube skin temperature prediction of catalytic reforming unit (CRU) heaters  

Science Conference Proceedings (OSTI)

The maximum duty of reformer heaters is governed by the occurance of maximum tube skin temperature of the heaters. The value of maximum tube skin temperatures of the heaters must not exceed theirs' maximum allowable design temperature. The paper highlights ... Keywords: coke formation, finite element, simulations, tube furnance

Suzana Yusup; Nguyen Duy Vinh; Nurhayati Mellon; Abdullah Hassan

2006-10-01T23:59:59.000Z

312

Fired heater for coal liquefaction process  

DOE Patents (OSTI)

A fired heater for a coal liquefaction process is constructed with a heat transfer tube having U-bends at regular intervals along the length thereof to increase the slug frequency of the multi-phase mixture flowing therethrough to thereby improve the heat transfer efficiency.

Ying, David H. S. (Macungie, PA)

1984-01-01T23:59:59.000Z

313

Consumer-products minimum energy-efficiency-standards program. Topical report on Subtask 3. 1. Evaluation of energy consumption savings of boost heaters in dishwashers  

SciTech Connect

An analysis of the energy conservation and life cycle cost benefits of boost heaters for dishwashers is presented to provide technical information to assist in determining whether to modify the dishwasher test procedure to include boost heaters. Two manufacturers are offering dishwashers which have an inlet water temperature requirement of 120/sup 0/F. Cleaning performance in these appliances is maintained with an electric coil in the sump of the dishwasher, which boosts the incoming water to its final temperature. Both manufacturers have petitioned DOE for exemption from efficiency standards, since current DOE test procedures give no credit for water heater energy savings. The evaluation shows boost heaters to be energy conserving for all conditions. The life cycle cost analysis indicates boost heaters are cost effective in all cases for homes with electric water heaters, and in most cases for homes having gas water heaters. Additionally the proposed standards for dishwashers will lower water consumption in 1985 model dishwashers such that boost heaters will become cost effective in all cases.

Not Available

1980-05-01T23:59:59.000Z

314

Solar-hot-water-heater lease program  

SciTech Connect

Ten domestic hot-water solar systems were installed, leased to homeowners, and monitored for two years. All of the systems were installed as back-ups to electric water heaters. The systems consist of two to four collectors, a solar storage tank (as well as the existing non-solar heater), and a heat exchanger package. Eight are three-collector systems, one is a four-collector and one a two-collector system. The systems were sized according to family size and predicted hot water demand. The monitoring consists of a separate KW reading on the non-solar water heater, a reading of gallons of how water consumed, and hot and cold outlet temperatures. The purpose for the study was fourfold: (1) to determine the level of acceptance by the general public of solar water heaters if available on a lease rather than a purchase basis; (2) to measure the actual energy savings to the average homeowner in central Illinois with a solar water heater; (3) to measure the potential reduction of Cilco's energy production requirements, should there be widespread utilization of these systems; and (4) to determine the feasibility of an entrepreneur making these systems available on a rental basis and remaining a going concern. The results of this study indicate that the leasing of solar equipment to homeowners has a more widespread acceptance than the direct purchase of such systems. Homeowners, however, do not want to spend as much money on monthly lease payments as the supplier of the equipment would deem necessary. This seriously questions the feasibility of an entrepreneurial leasing program.

Rutherford, S.

1983-04-01T23:59:59.000Z

315

Analysis of a hybrid UFAD and radiant hydronic slab HVAC system  

E-Print Network (OSTI)

Air- Conditioning Engineers HVAC & R Research, vol. 50, Sep.and radiant hydronic slab HVAC system.   Paul RAFTERY a,* ,of a novel integrated HVAC system. This system combines an

Raftery, Paul; Lee, Kwang Ho; Webster, Thomas; Bauman, Fred

2011-01-01T23:59:59.000Z

316

Determination of Unfiltered Radiances from the Clouds and the Earth’s Radiant Energy System Instrument  

Science Conference Proceedings (OSTI)

A new method for determining unfiltered shortwave (SW), longwave (LW), and window radiances from filtered radiances measured by the Clouds and the Earth’s Radiant Energy System (CERES) satellite instrument is presented. The method uses ...

Norman G. Loeb; Kory J. Priestley; David P. Kratz; Erika B. Geier; Richard N. Green; Bruce A. Wielicki; Patricia O’Rawe Hinton; Sandra K. Nolan

2001-04-01T23:59:59.000Z

317

Clouds and the Earth's Radiant Energy System (CERES): An Earth Observing System Experiment  

Science Conference Proceedings (OSTI)

Clouds and the Earth's Radiant Energy System (CERES) is an investigation to examine the role of cloud/radiation feedback in the Earth's climate system. The CERES broadband scanning radiometers are an improved version of the Earth Radiation Budget ...

Bruce A. Wielicki; Bruce R. Barkstrom; Edwin F. Harrison; Robert B. Lee III; G. Louis Smith; John E. Cooper

1996-05-01T23:59:59.000Z

318

Temporal Interpolation Methods for the Clouds and the Earth’s Radiant Energy System (CERES) Experiment  

Science Conference Proceedings (OSTI)

The Clouds and the Earth’s Radiant Energy System (CERES) is a NASA multisatellite measurement program for monitoring the radiation environment of the earth–atmosphere system. The CERES instrument was flown on the Tropical Rainfall Measuring ...

D. F. Young; P. Minnis; D. R. Doelling; G. G. Gibson; T. Wong

1998-06-01T23:59:59.000Z

319

Analysis of a hybrid UFAD and radiant hydronic slab HVAC system  

E-Print Network (OSTI)

radiant ceiling slab. A cooling tower supplies water to pre-served by a free-cooling tower to pre-cool the buildingcoils. A two-speed cooling tower combined with a plate heat

Raftery, Paul; Lee, Kwang Ho; Webster, Thomas; Bauman, Fred

2011-01-01T23:59:59.000Z

320

Effects of Radiant Barrier Systems on Ventilated Attics in a Hot and Humid Climate  

E-Print Network (OSTI)

Results of side-by-side radiant barrier experiments using two identical 144 ft2 (nominal) test houses are presented. The test houses responded very similarly to weather variations prior to the retrofit. The temperatures of the test houses were controlled to within 0.3°F. Ceiling heat fluxes were within 2 percent for each house. The results showed that a critical attic ventilation flow rate (0.25 CFM/ft2 ) existed after which the percentage reduction produced by the radiant barrier systems was not sensitive to increased airflows. The ceiling heat flux reductions produced by the radiant barrier systems were between 25 and 34 percent, with 28 percent being the reduction observed most often in the presence of attic ventilation. All results presented in this paper were for attics with R-19 unfaced fiberglass insulation and for a perforated radiant barrier with low emissivities on both sides.

Medina, M. A.; O'Neal, D. L.; Turner, W. D.

1992-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

INTERNATIONAL COMPARISON OF RESIDENTIAL GAS USE AND CONSERVATION  

E-Print Network (OSTI)

gas water heaters, While we have not begun to model energy use as a function of prices we are aware of the trends

Schipper, Lee

2011-01-01T23:59:59.000Z

322

New England Gas Company - Residential and Commercial Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New England Gas Company - Residential and Commercial Energy New England Gas Company - Residential and Commercial Energy Efficiency Rebate Programs New England Gas Company - Residential and Commercial Energy Efficiency Rebate Programs < Back Eligibility Commercial Fed. Government Local Government Nonprofit Residential State Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Heat Pumps Appliances & Electronics Water Heating Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Residential Furnace: $300 - $450 Boilers: $1000 - $1500 Combined High Efficiency Boiler/Water Heater: $1,200 Heat Recovery Ventilator: $500 High Efficiency Indirect Water Heater: $400 Condensing Gas Water Heater: $500 High Efficiency On-Demand, Tankless Water Heater: $500 - $800

323

Columbia Gas of Virginia- Business Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Gas of Virginia offers rebates to commercial customers for the purchase and installation of energy efficient equipment. Water heaters, furnaces, boilers and controls, laundromat clothes...

324

Colorado Natural Gas - Energy Efficiency Rebate Program | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Thermostat: 25 Miscellaneous Measures: 25 Integrated Space and Water Heater: 300 Colorado Natural Gas offers the Excess is Out Program for residential and commercial...

325

Columbia Gas of Virginia- Home Savings Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Gas of Virginia offers rebates to residential customers for the purchase and installation of energy efficient appliances and equipment. Water heaters, furnaces, windows, insulation and...

326

Design and Experiments of a Solar Low-temperature Hot Water Floor Radiant Heating System  

E-Print Network (OSTI)

The solar low-temperature hot water floor radiant heating system combines solar energy heating with floor radiant heating. This kind of environmental heating way not only saves fossil resources and reduces pollution, but also makes people feel more comfortable. First, the authors devised an experimental scheme and set up the laboratory. Second, we collected a great deal of data on the system in different situations. Finally, we conclude that such heating system is feasible and one of the best heating methods.

Wu, Z.; Li, D.

2006-01-01T23:59:59.000Z

327

Radiant cooling in US office buildings: Towards eliminating the perception of climate-imposed barriers  

Science Conference Proceedings (OSTI)

Much attention is being given to improving the efficiency of air-conditioning systems through the promotion of more efficient cooling technologies. One such alternative, radiant cooling, is the subject of this thesis. Performance information from Western European buildings equipped with radiant cooling systems indicates that these systems not only reduce the building energy consumption but also provide additional economic and comfort-related benefits. Their potential in other markets such as the US has been largely overlooked due to lack of practical demonstration, and to the absence of simulation tools capable of predicting system performance in different climates. This thesis describes the development of RADCOOL, a simulation tool that models thermal and moisture-related effects in spaces equipped with radiant cooling systems. The thesis then conducts the first in-depth investigation of the climate-related aspects of the performance of radiant cooling systems in office buildings. The results of the investigation show that a building equipped with a radiant cooling system can be operated in any US climate with small risk of condensation. For the office space examined in the thesis, employing a radiant cooling system instead of a traditional all-air system can save on average 30% of the energy consumption and 27% of the peak power demand due to space conditioning. The savings potential is climate-dependent, and is larger in retrofitted buildings than in new construction. This thesis demonstrates the high performance potential of radiant cooling systems across a broad range of US climates. It further discusses the economics governing the US air-conditioning market and identifies the type of policy interventions and other measures that could encourage the adoption of radiant cooling in this market.

Stetiu, C.

1998-01-01T23:59:59.000Z

328

Burbank Water and Power - Solar Water Heater Rebate Program (California) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Burbank Water and Power - Solar Water Heater Rebate Program Burbank Water and Power - Solar Water Heater Rebate Program (California) Burbank Water and Power - Solar Water Heater Rebate Program (California) < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount $1,500 Provider Rebates Burbank Water and Power is providing incentives for the purchase of solar water heaters. Incentives are only available to residential customers with electric water heaters. There is a limit of one solar water heater per year per property. Applicants must provide access to their residence for a pre-inspection to verify the existing use of an electric water heater. Customers must comply with all code and permit requirements. More

329

TVA Partner Utilities - Energy Right' Water Heater Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Right' Water Heater Program Right&#039; Water Heater Program TVA Partner Utilities - Energy Right' Water Heater Program < Back Eligibility Installer/Contractor Residential Utility Savings Category Appliances & Electronics Water Heating Maximum Rebate Member utility water heater rebate programs can range from $25 to total cost. Program Info State Mississippi Program Type Utility Rebate Program Rebate Amount Energy Efficient Water Heater: $50 from TVA Provider Tennessee Valley Authority The TVA energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local power companies for each installation. Power Companies may pass these incentives on to customers. Customers should contact their local power company to see what programs are

330

NREL Tests Integrated Heat Pump Water Heater Performance in Different Climates (Fact Sheet)  

SciTech Connect

This technical highlight describes NREL tests to capture information about heat pump performance across a wide range of ambient conditions for five heat pump water heaters (HPWH). These water heaters have the potential to significantly reduce water heater energy use relative to traditional electric resistance water heaters. These tests have provided detailed performance data for these appliances, which have been used to evaluate the cost of saved energy as a function of climate. The performance of HPWHs is dependent on ambient air temperature and humidity and the logic controlling the heat pump and the backup resistance heaters. The laboratory tests were designed to measure each unit's performance across a range of air conditions and determine the specific logic controlling the two heat sources, which has a large effect on the comfort of the users and the energy efficiency of the system. Unlike other types of water heaters, HPWHs are both influenced by and have an effect on their surroundings. Since these effects are complex and different for virtually every house and climate region, creating an accurate HPWH model from the data gathered during the laboratory tests was a main goal of the project. Using the results from NREL's laboratory tests, such as the Coefficient of Performance (COP) curves for different air conditions as shown in Figure 1, an existing HPWH model is being modified to produce more accurate whole-house simulations. This will allow the interactions between the HPWH and the home's heating and cooling system to be evaluated in detail, for any climate region. Once these modeling capabilities are in place, a realistic cost-benefit analysis can be performed for a HPWH installation anywhere in the country. An accurate HPWH model will help to quantify the savings associated with installing a HPWH in the place of a standard electric water heater. In most locations, HPWHs are not yet a cost-effective alternative to natural gas water heaters. The detailed system performance maps that were developed by this testing program will be used to: (1) Target regions of the country that would benefit most from this technology; (2) Identify improvements in current systems to maximize homeowner cost savings; and (3) Explore opportunities for development of advanced hot water heating systems.

Not Available

2012-01-01T23:59:59.000Z

331

Buildings Energy Data Book: 5.4 Water Heaters  

Buildings Energy Data Book (EERE)

5 5 Water Heater Efficiencies 2005 2010 Efficiency Stock Minimum Best-Available Residential Type Parameter (1) Efficiency New Efficiency New Efficiency Electric Storage EF 0.90 0.90 (2) 0.95 (2) Electric Instantaneous EF 0.82 0.82 0.98 Electric Heat Pump EF 2.00 2.00 2.35 Gas-Fired Storage EF 0.60 0.59 (3) 0.85 (3) Gas-Fired Instantaneous EF 0.82 0.82 0.98 Oil-Fired Storage EF 0.50 0.53 (4) 0.68 (4) Solar SEF 2.50 N.A. 2.50 2007 2010 Efficiency Stock Minimum Best-Available Commercial Type Parameter (1) Efficiency New Efficiency New Efficiency Electric Storage Thermal Efficiency 0.98 0.98 (5) 0.98 (5) Electric Instantaneous Thermal Efficiency 0.98 0.98 0.98 Gas-Fired Storage Thermal Efficiency 0.78 0.80 (6) 0.96 (6) Gas-Fired Instantaneous Thermal Efficiency 0.77 0.80 0.85 Oil-Fired Storage Thermal Efficiency 0.79 0.78 (7) 0.85 (7) Note(s):

332

Numerical heat transfer attic model using a radiant barrier system  

Science Conference Proceedings (OSTI)

A two-dimensional, steady-state finite-element model was developed to simulate the thermal effects of the application of an attic radiant barrier system (ARBS) inside a ventilated residential attic. The attic is ventilated using the exhaust air from an evaporative cooler. The study uses a {kappa}-{epsilon} turbulent model to describe the velocity and temperature distributions in the attic. The ambient temperature and solar isolation densities on the outside inclined attic surfaces are used as driving functions for the model. The model also included the appropriate heat exchange modes of convection and radiation on these outside surfaces. Several recirculation zones were visually observed in the attic flow pattern. Also, the use of the ARBS seems to lower the heat transfer through the ceiling by 25--30%, but this effect decreases significantly as the outside ventilation rates are increased through the attic space. The 2D model revealed some interesting temperature distributions along the attic surfaces that could not have been predicted by the one-dimensional models. The lower emissivity ARBS seems to raise the temperature of the inclined attic surfaces as well as the temperature of the exhausted ventilation air.

Moujaes, S.F.; Alsaiegh, N.T.

2000-04-01T23:59:59.000Z

333

Analysis of Attic Radiant Barrier Systems Using Mathematical Models  

E-Print Network (OSTI)

During the past six years, the Florida Solar Energy Center (FSEC) has conducted extensive experimental research on radiant barrier systems (RBS). This paper presents recent research on the development of mathematical attic models. Two levels of modeling capability have been developed. A very simplified model based on ASHRAE procedures in used to study the sensitivity of RBS performance parameters, and a very detailed finite element model is used to study highly complex phenomena, including moisture adsorption and desorption in attics. The speed of the simple model allows a large range of attic parameters to be studies quickly, and the finite element model provides a detailed understanding of combined heat and moisture transport in attics. This paper concentrates on a parametric analysis of attic RBS using the simplified model. The development of the model is described, and results of the parametric analyses are presented and discussed. Preliminary results from the finite element model are also compared with measurements from a test attic to illustrate the effects of moisture adsorption and desorption in common attics.

Fairey, P.; Swami, M.

1988-01-01T23:59:59.000Z

334

Piedmont Natural Gas- Commercial Equipment Efficiency Program  

Energy.gov (U.S. Department of Energy (DOE))

Piedmont Natural Gas offers rebates to commercial customers for purchasing and installing high-efficiency natural gas tankless water heaters. Customers on the 102-Small General Service and 152...

335

Condensing Hybrid Water Heater Monitoring Field Evaluation  

NLE Websites -- All DOE Office Websites (Extended Search)

Condensing Hybrid Water Heater Condensing Hybrid Water Heater Monitoring Field Evaluation Jeff Maguire, Lieko Earle, and Chuck Booten National Renewable Energy Laboratory C.E. Hancock Mountain Energy Partnership Produced under direction of the Sacramento Municipal Utilities District by the National Renewable Energy Laboratory (NREL) under Interagency Agreement CRD-05-168 and Task No WR49.3000. Technical Report NREL/TP-5500-52234 October 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308

336

AWSWAH - the heat pipe solar water heater  

Science Conference Proceedings (OSTI)

An all weather heat pipe solar water heater (AWSWAH) comprising a collector of 4 m/sup 2/ (43 ft/sup 2/) and a low profile water tank of 160 liters (42 gal.) was developed. A single heat pipe consisting of 30 risers and two manifolds in the evaporator and a spiral condenser was incorporated into the AWSWAH. Condensate metering was done by synthetic fiber wicks. The AWSWAH was tested alongside two conventional solar water heaters of identical dimensions, an open loop system and a closed loop system. It was found that the AWSWAH was an average of 50% more effective than the open system in the temperature range 30-90 /sup 0/C (86-194 /sup 0/F). The closed loop system was the least efficient of the three systems.

Akyurt, M.

1986-01-01T23:59:59.000Z

337

Solar water heater lease program. Interim report  

SciTech Connect

The Solar Water Heater Lease Program consists of the installation and leasing of ten solar systems to central Illinois homeowners. The measured energy savings to the homeowners and the impact of such systems on energy production requirements are studied. Each homeowner collects data on the gallons of hot water used, electricity used to heat water, and the temperatures of the cold and hot water outlet temperatures at the sink. The data are presented and conclusions are drawn, including the optimum slope of the collector, comparison of the actual hot water consumption and the estimated consumption, evaluation of the effects of temperature settings of the non-solar water heater, and the percentage of the energy provided for hot water by the solar system. The monitoring procedures and results are evaluated. Recommendations for improving the solar hot water systems are presented. (LEW)

1982-01-01T23:59:59.000Z

338

Electric heater for nuclear fuel rod simulators  

DOE Patents (OSTI)

The present invention is directed to an electric cartridge-type heater for use as a simulator for a nuclear fuel pin in reactor studies. The heater comprises an elongated cylindrical housing containing a longitudinally extending helically wound heating element with the heating element radially inwardly separated from the housing. Crushed cold-pressed preforms of boron nitride electrically insulate the heating element from the housing while providing good thermal conductivity. Crushed cold-pressed preforms of magnesia or a magnesia-15 percent boron nitride mixture are disposed in the cavity of the helical heating element. The coefficient of thermal expansion of the magnesia or the magnesia-boron nitride mixture is higher than that of the boron nitride disposed about the heating element for urging the boron nitride radially outwardly against the housing during elevated temperatures to assure adequate thermal contact between the housing and the boron nitride.

McCulloch, Reginald W. (Knoxville, TN); Morgan, Jr., Chester S. (Oak Ridge, TN); Dial, Ralph E. (Concord, TN)

1982-01-01T23:59:59.000Z

339

Field Monitoring Protocol: Heat Pump Water Heaters  

SciTech Connect

This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

Sparn, B.; Earle, L.; Christensen, D.; Maguire, J.; Wilson, E.; Hancock, E.

2013-02-01T23:59:59.000Z

340

Tubular electric heater with a thermocouple assembly  

DOE Patents (OSTI)

This patent relates to a thermocouple or other instrumentation which is installed within the walls of a tubular sheath surrounding a process device such as an electric heater. The sheath comprises two concentric tubes, one or both of which have a longitudinal, concave crease facing the other tube. The thermocouple is fixedly positioned within the crease and the outer tube is mechanically reduced to form an interference fit onto the inner tube. (auth)

House, R.K.; Williams, D.E.

1975-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Analysisi Benchmark of the Single Heater Test  

SciTech Connect

The Single Heater Test (SHT) is the first of three in-situ thermal tests included in the site characterization program for the potential nuclear waste monitored geologic repository at Yucca Mountain. The heating phase of the SHT started in August 1996 and was concluded in May 1997 after 9 months of heating. Cooling continued until January 1998, at which time post-test characterization of the test block commenced. Numerous thermal, hydrological, mechanical, and chemical sensors monitored the coupled processes in the unsaturated fractured rock mass around the heater (CRWMS M&O 1999). The objective of this calculation is to benchmark a numerical simulation of the rock mass thermal behavior against the extensive data set that is available from the thermal test. The scope is limited to three-dimensional (3-D) numerical simulations of the computational domain of the Single Heater Test and surrounding rock mass. This calculation supports the waste package thermal design methodology, and is developed by Waste Package Department (WPD) under Office of Civilian Radioactive Waste Management (OCRWM) procedure AP-3.12Q, Revision 0, ICN 3, BSCN 1, Calculations.

H.M. Wade; H. Marr; M.J. Anderson

2006-07-27T23:59:59.000Z

342

Primary heater module, Phase II. Volume V. Final report, February 1980-November 1983  

Science Conference Proceedings (OSTI)

Research was conducted on components and subassemblies of coal-fired heaters suitable to supply the heat input to closed-cycle gas turbine-based cogeneration systems of 25 to 50 MWe electrical output. Three concepts are researched. The program results indicate that each of the three heater concepts is technically feasible. The fluidized bed concepts are judged most likely to be both technically and commercially feasible. Their continued development is recommended. Vol. 5 consists of Appendix A, which consists of 44 engineering drawings and Appendix B. Appendix B provides a discussion of CCGT-based cogeneration cycle performance. Comparisons are made with OCGT and stream turbine-based cogeneration. The thermodynamic efficiency effects and the effects on the fired heater of variations in cycle operating parameters are discussed. These considerations underlie the conceptual commercial design concepts which, in turn, were used as the basis for identifying the technical issues researched in the AC21-80-ET15020 program. A subsection presents comparisons of steam turbine-based, open-cycle gas turbine (OCGT), and closed-cycle gas turbine (CCGT) based cogeneration systems and discusses the power to heat load ranges and profiles most economically served by each of the three systems. Controllability and operability of each system in conjunction with an AFB combustor also are discussed.

Campbell, J.

1983-12-01T23:59:59.000Z

343

Dominion East Ohio (Gas) - Home Performance Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Dominion East Ohio (Gas) - Home Performance Program Dominion East Ohio (Gas) - Home Performance Program Dominion East Ohio (Gas) - Home Performance Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Sealing Your Home Design & Remodeling Windows, Doors, & Skylights Ventilation Manufacturing Appliances & Electronics Water Heating Program Info State Ohio Program Type Utility Rebate Program Rebate Amount Furnace: $300-$400 Boiler: $250-$300 Duct Sealing: $40/hour Air Sealing: $40/hour Programmable Thermostat: $30/thermostat Storage Water Heater: $100 Tankless Water Heater: $150 Condensing Water Heater: $125 Water Heater Tank Insulation: $10 Attic Access Insulation: $30 Wall/Attic/Duct Insulation: $0.30/sq. ft.

344

Piedmont Natural Gas - Residential Equipment Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Piedmont Natural Gas - Residential Equipment Efficiency Program Piedmont Natural Gas - Residential Equipment Efficiency Program Piedmont Natural Gas - Residential Equipment Efficiency Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Water Heating Maximum Rebate 2 rebates per household Program Info State North Carolina Program Type Utility Rebate Program Rebate Amount High-Efficiency Furnace: $175 Tankless Water Heater: $150 Tank Water Heater: $50 Provider Gas Technology and Energy Services Piedmont Natural Gas offers rebates on high-efficiency natural gas tankless water heaters, tank water heaters and furnaces. Customers on the 101-Residential Service rate are eligible for these rebates. Rebates are only provided for qualifying natural gas equipment that is installed to

345

Insulated conductor temperature limited heater for subsurface heating coupled in a three-phase WYE configuration  

Science Conference Proceedings (OSTI)

A heating system for a subsurface formation is described. The heating system includes a first heater, a second heater, and a third heater placed in an opening in the subsurface formation. Each heater includes: an electrical conductor; an insulation layer at least partially surrounding the electrical conductor; and an electrically conductive sheath at least partially surrounding the insulation layer. The electrical conductor is electrically coupled to the sheath at a lower end portion of the heater. The lower end portion is the portion of the heater distal from a surface of the opening. The first heater, the second heater, and the third heater are electrically coupled at the lower end portions of the heaters. The first heater, the second heater, and the third heater are configured to be electrically coupled in a three-phase wye configuration.

Vinegar, Harold J. (Bellaire, TX); Sandberg, Chester Ledlie (Palo Alto, CA)

2010-11-09T23:59:59.000Z

346

Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Linn County Rural Electric Cooperative - Solar Water Heater Rebate Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program < Back Eligibility Agricultural Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Iowa Program Type Utility Rebate Program Rebate Amount $500 Provider Linn County Rural Electric Cooperative Association Linn County Rural Electric Cooperative Association (Linn County RECA) is a member-owned cooperative. To encourage energy efficiency, Linn County offers a number of rebates to commercial, residential, and agricultural customers. Owners of both new construction and existing buildings are eligible for a $500 rebate for solar water heaters. The water heaters must have an auxiliary tank of at least 40 gallons and the solar water heater

347

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Water Heater: up to $275 Heat Pump Replacement: $400 Provider Rock Hill Utilities Through the SmartChoice program, Rock Hill Utilities offers rebates for water heater and heat pump replacements. Information on financing for heat pumps can also be found on the web site listed above. If both the water heater and heat pump are purchased then the customer may qualify for the Great Rate program. The Great Rate program will add a 25% discount to a

348

Automated robotic equipment for ultrasonic inspection of pressurizer heater wells  

DOE Patents (OSTI)

A robotic device for remotely inspecting pressurizer heater wells is provided which has the advantages of quickly, precisely, and reliably acquiring data at reasonable cost while also reducing radiation exposure of an operator. The device comprises a prober assembly including a probe which enters a heater well, gathers data regarding the condition of the heater well and transmits a signal carrying that data; a mounting device for mounting the probe assembly at the opening of the heater well so that the probe can enter the heater well; a first motor mounted on the mounting device for providing movement of the probe assembly in an axial direction; and a second motor mounted on the mounting device for providing rotation of the probe assembly. This arrangement enables full inspection of the heater well to be carried out.

Nachbar, Henry D. (Ballston Lake, NY); DeRossi, Raymond S. (Amsterdam, NY); Mullins, Lawrence E. (Middle Grove, NY)

1993-01-01T23:59:59.000Z

349

Carbon Dioxide Heat Pump Water Heater Research Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Research Project Carbon Dioxide Heat Pump Water Heater Research Project The U.S. Department of Energy is currently conducting research into carbon dioxide (CO2) heat pump water heaters. This project will employ innovative techniques to adapt water heating technology to meet U.S. market requirements, including specifications, cost, and performance targets. Carbon dioxide is a refrigerant with a global warming potential (GWP) of 1. The CO2 heat pump water heater research seeks to develop an improved life cycle climate performance compared to conventional refrigerants. For example, R134a, another type of refrigerant, has a GWP of 1,300. Project Description This project seeks to develop a CO2-based heat pump water heater (HPWH)

350

Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Aiken Electric Cooperative Inc - Residential Water Heater Rebate Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Free high efficiency water Heater; $200 installation fee Water heater and timer with normal installation: $2.50 credit for 10 years Timer only: $200 cash payment and $2.50 credit for 10 years New construction contract home: $250 Provider Aiken Electric Cooperative Aiken Electric Cooperative offers residential members rebates for installing high-efficiency electric water heaters and/or timers in their homes. Customers have four rebate options:

351

The Trials and Tribulations of Testing Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

The Trials and Tribulations of Testing Water Heaters The Trials and Tribulations of Testing Water Heaters Speaker(s): James Lutz Date: August 14, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Julie Osborn During our work on efficiency standards for electric water heaters, we discovered significant discrepancies between the rated and tested efficiencies of the highest rated electric resistance water heaters. For high efficiency electric resistance water heaters with an Energy Factor above .92, the heat losses are so small that minor flaws in the tank or obscure problems in the test procedure become more apparent. This seminar reports on our investigation into the causes of inconsistent results obtained during testing of high efficiency electric resistance water heaters at different test labs. We discovered some reasons for the

352

Automated robotic equipment for ultrasonic inspection of pressurizer heater wells  

DOE Patents (OSTI)

A robotic device for remotely inspecting pressurizer heater wells is provided which has the advantages of quickly, precisely, and reliably acquiring data at reasonable cost while also reducing radiation exposure of an operator. The device comprises a probe assembly including a probe which enters a heater well, gathers data regarding the condition of the heater well and transmits a signal carrying that data; a mounting device for mounting the probe assembly at the opening of the heater well so that the probe can enter the heater well; a first motor mounted on the mounting device for providing movement of the probe assembly in an axial direction; and a second motor mounted on the mounting device for providing rotation of the probe assembly. This arrangement enables full inspection of the heater well to be carried out.

Nachbar, H.D.; DeRossi, R.S.; Mullins, L.E.

1991-12-31T23:59:59.000Z

353

Forecast of thermal-hydrological conditions and air injection test results of the single heater test at Yucca Mountain  

E-Print Network (OSTI)

ESF Single Heater Test, Sandia National Laboratories Letterthe Single Heater Test by Sandia (Sobolik et al. , 1996).the Single Heater Test by Sandia (Sobolik etal. , 1996). cap

Birkholzer, J.T.

2010-01-01T23:59:59.000Z

354

Advances in the Research of Heat Pump Water Heaters  

E-Print Network (OSTI)

This paper presents the progress of many recently correlative research works on the heat pump water heater (HPWH) and on solar-assisted heat pump water heaters. The advances in the research on compressor development, alternative refrigerant technology for a compressor HPWH are separately summarized. A new study on frosting/defrosting of an air source heat pump water heater (ASHPWH) is also discussed. The trends of some new technologies of HPWH are analyzed.

Shan, S.; Wang, D.; Wang, R.

2006-01-01T23:59:59.000Z

355

Multi-step heater deployment in a subsurface formation  

SciTech Connect

A method for installing a horizontal or inclined subsurface heater includes placing a heating section of a heater in a horizontal or inclined section of a wellbore with an installation tool. The tool is uncoupled from the heating section. A lead in section is mechanically and electrically coupled to the heating section of the heater. The lead-in section is located in an angled or vertical section of the wellbore.

Mason, Stanley Leroy (Allen, TX)

2012-04-03T23:59:59.000Z

356

Influence of Attic Radiant Barrier Systems on Air Conditioning Demand in an Utility Pilot Project  

E-Print Network (OSTI)

A utility monitoring project has evaluated radiant barrier systems (RBS) as a new potential demand site management (DSM) program. The study examined how the retrofit of attic radiant barriers can be expected to alter utility residential space conditioning loads. An RBS consists of a layer of aluminum foil fastened to roof decking or roof trusses to block radiant heat transfer between the hot roof surface and the attic below. The radiant barrier can significantly lower summer heat transfer to the attic insulation and to the cooling duct system. Both of these mechanisms have strong potential impacts on cooling energy use as illustrated in Figures 1 and 2. The pilot project involved installation of RBS in nine homes that had been extensively monitored over the preceding year. The houses varied in conditioned floor area from 939 to 2,440 square feet; attic insulation varied from R-9 to R-30. The homes had shingle roofs with varying degrees of attic ventilation. The radiant barriers were installed during the summer of 2000. Data analysis on the pre and post cooling and heating consumption was used to determine impacts on energy use and peak demand for the utility. The average cooling energy savings from the RBS retrofit was 3.6 kWh/day, or about 9%. The average reduction in summer afternoon peak demand was 420 watts (or about 16%).

Parker, D. S.; Sherwin, J. R.

2002-01-01T23:59:59.000Z

357

Thermal Performance Evaluation of Attic Radiant Barrier Systems Using the Large Scale Climate Simulator (LSCS)  

SciTech Connect

Application of radiant barriers and low-emittance surface coatings in residential building attics can significantly reduce conditioning loads from heat flow through attic floors. The roofing industry has been developing and using various radiant barrier systems and low-emittance surface coatings to increase energy efficiency in buildings; however, minimal data are available that quantifies the effectiveness of these technologies. This study evaluates performance of various attic radiant barrier systems under simulated summer daytime conditions and nighttime or low solar gain daytime winter conditions using the large scale climate simulator (LSCS). The four attic configurations that were evaluated are 1) no radiant barrier (control), 2) perforated low-e foil laminated oriented strand board (OSB) deck, 3) low-e foil stapled on rafters, and 4) liquid applied low-emittance coating on roof deck and rafters. All test attics used nominal RUS 13 h-ft2- F/Btu (RSI 2.29 m2-K/W) fiberglass batt insulation on attic floor. Results indicate that the three systems with radiant barriers had heat flows through the attic floor during summer daytime condition that were 33%, 50%, and 19% lower than the control, respectively.

Shrestha, Som S [ORNL] [ORNL; Miller, William A [ORNL] [ORNL; Desjarlais, Andre Omer [ORNL] [ORNL

2013-01-01T23:59:59.000Z

358

Economic Evaluation of Insulation/Radiant Barrier Systems for the State of Texas  

E-Print Network (OSTI)

This paper presents simulated performance of insulation/radiant barrier systems under different Texas climates. A transient heat and mass transfer model which predicts thermal performance of residential attics (Medina, 1992) was coupled with an "economic" subroutine. Simple payback periods were estimated which were based on current insulation and radiant barrier (RB) prices (materials and installation), and current and forecast electric rates. It was found that when the analyses were based solely on reductions of ceiling heat loads during the summer time, a combination of R-11 with RB was more effective than upgrading the insulation level to R-19. Similarly, adding a radiant barrier to an existing insulation level of R-19 proved more effective than upgrading to R-30. When heat gains to the cold air traveling inside A/C ducts (\\which are usually installed in attic spaces) were considered, all insulation/radiant barrier combinations showed faster payback periods than insulation upgrades, During the winter time, insulation upgrades proved to be more effective than insulation/radiant barrier combinations. The simple payback analyses presented herein include both summer and winter simulations.

Medina, M. A.; Turner, W. D.; O'Neal, D. L.

1994-01-01T23:59:59.000Z

359

GeoSprings Hybrid Water Heater - Energy Innovation Portal  

The GeoSpring Hybrid Water Heater creates the same amount of hot water as a traditional electric ... Hydrogen and Fuel Cell; Hydropower, Wave and ...

360

Cost of Increased Energy Efficiency for Residential Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

distributor, and installer costs are used to calculate the costs of different water heater designs. Consumer operating expenses are calculated based on the modeled energy...

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet)  

SciTech Connect

A new simulation model helps researchers evaluate real-world impacts of heat pump water heaters in U.S. homes.

Hudon, K.

2012-05-01T23:59:59.000Z

362

Energy Saving Absorption Heat Pump Water Heater - Energy ...  

ORNL’s new absorption heat pump and water heater technology offers substantial energy savings and can reduce the use of fossil fuels by buildings. While ...

363

Condensing Side-Arm Water Heater - Energy Innovation Portal  

The condensing side-arm element recirculates exhaust gases into heating the cooler part of a water heater tank by the ... Building Energy ... Solar Thermal;

364

Cascade Natural Gas - Conservation Incentives for New Homes | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cascade Natural Gas - Conservation Incentives for New Homes Cascade Natural Gas - Conservation Incentives for New Homes Cascade Natural Gas - Conservation Incentives for New Homes < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Construction Commercial Heating & Cooling Design & Remodeling Sealing Your Home Ventilation Heating Appliances & Electronics Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount High Efficiency Natural Gas Furnace: $150 High Efficiency Natural Gas Hearth: $70 Conventional Natural Gas Water Heater: $40 Condensing Tankless Water Heater: $200 Combined Domestic Water/Hydronic Space Heating System (usingTankless Water Heater): $800 Energy Star Certified Home: $350 Energy Star Certified Plus Home: $750

365

LOW COST HEAT PUMP WATER HEATER (HPWH)  

Science Conference Proceedings (OSTI)

Water heating accounts for the second largest portion of residential building energy consumption, after space conditioning. Existing HPWH products are a technical success, with demonstrated energy savings of 50% or more compared with standard electric resistance water heaters. However, current HPWHs available on the market cost an average of $1000 or more, which is too expensive for significant market penetration. What is needed is a method to reduce the first cost of HPWHs, so that the payback period will be reduced from 8 years to a period short enough for the market to accept this technology. A second problem with most existing HPWH products is the reliability issue associated with the pump and water loop needed to circulate cool water from the storage tank to the HPWH condenser. Existing integral HPWHs have the condenser wrapped around the water tank and thus avoid the pump and circulation issues but require a relatively complex and expensive manufacturing process. A more straightforward potentially less costly approach to the integral, single package HPWH design is to insert the condenser directly into the storage tank, or immersed direct heat exchanger (IDX). Initial development of an IDX HPWH met technical performance goals, achieving measured efficiencies or energy factors (EF) in excess of 1.79. In comparison conventional electric water heaters (EWH) have EFs of about 0.9. However, the initial approach required a 2.5" hole on top of the tank for insertion of the condenser - much larger than the standard openings typically provided. Interactions with water heater manufacturers indicated that the non standard hole size would likely lead to increased manufacturing costs (at least initially) and largely eliminate any cost advantage of the IDX approach. Recently we have been evaluating an approach to allow use of a standard tank hole size for insertion of the IDX condenser. Laboratory tests of a prototype have yielded an EF of 2.02.

Mei, Vince C [ORNL; Baxter, Van D [ORNL

2006-01-01T23:59:59.000Z

366

Energy, cost, and CO 2 emission comparison between radiant wall panel systems and radiator systems  

E-Print Network (OSTI)

The main goal of this paper is to evaluate the possibility of application or replacement of radiators with low-temperature radiant panels. This paper shows the comparison results of operations of 4 space heating systems: the low-temperature radiant panel system without any additional thermal insulation of external walls (PH-WOI), the low-temperature radiant panel system with additional thermal insulation of external walls (PH-WI), the radiator system without any additional thermal insulation of external walls (the classical heating system) (RH-WOI), and the radiator system with additional thermal insulation of external walls (RH-WI). The operation of each system is simulated by software EnergyPlus. The investigation shows that the PH-WI gives the best results. The RH-WOI has the largest energy consumption, and the largest pollutant emission. However, the PH-WI requires the highest investment.

Milorad Boji?; Dragan Cvetkovi?; Marko Mileti?; Jovan Maleševi?; Harry Boyer

2012-12-18T23:59:59.000Z

367

Review of International Methods of Test to Rate the Efficiency of Water Heaters  

E-Print Network (OSTI)

test procedures for solar water heaters characterizes systemWasted water Solar Heat pump water heater Australia/Newwater_heaters/Annex_IV_8July08 International Organization for Standardization, "Draft International Standard ISO/DIS 9459-4 Solar

Lutz, Jim

2012-01-01T23:59:59.000Z

368

Georgia Power- Residential Solar and Heat Pump Water Heater Rebate (Georgia)  

Energy.gov (U.S. Department of Energy (DOE))

Georgia Power customers may be eligible for rebates up to $250 each toward the installation costs of a 50 gallon or greater solar water heater or heat pump water heater. The solar water heater or...

369

How Do You Use a Space Heater Efficiently? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Use a Space Heater Efficiently? How Do You Use a Space Heater Efficiently? January 13, 2011 - 6:30am Addthis On Monday, Andrea explored the question of space heaters and found that...

370

Application of a Linear Input/Output Model to Tankless Water Heaters  

DOE Green Energy (OSTI)

In this study, the applicability of a linear input/output model to gas-fired, tankless water heaters has been evaluated. This simple model assumes that the relationship between input and output, averaged over both active draw and idle periods, is linear. This approach is being applied to boilers in other studies and offers the potential to make a small number of simple measurements to obtain the model parameters. These parameters can then be used to predict performance under complex load patterns. Both condensing and non-condensing water heaters have been tested under a very wide range of load conditions. It is shown that this approach can be used to reproduce performance metrics, such as the energy factor, and can be used to evaluate the impacts of alternative draw patterns and conditions.

Butcher T.; Schoenbauer, B.

2011-12-31T23:59:59.000Z

371

Analysis in Support of the Radiant Barrier Fact Sheet 2010 Update  

Science Conference Proceedings (OSTI)

Quantifying the benefits of radiant barriers is complex because the benefits depend upon the climate, attic geometry, duct arrangements, and other building parameters. Homeowners, however, require simplified guidance regarding building envelope options, even those options that seem to have no simple answers. An extensive parametric evaluation of radiant barrier installation alternatives was made using a newly expanded and benchmarked version of an attic simulation program. To complement this anal- ysis, a detailed numerical analysis of radiation heat transfer within the attic and within the small space bounded by the rafters and the sheathing was completed. The results provide guidance for homeowners and builders.

Stovall, Therese K [ORNL; Shrestha, Som S [ORNL; Arimilli, Rao V [ORNL; Yarbrough, David W [ORNL; Pearson, Thomas [ASHRAE, Student Member

2010-01-01T23:59:59.000Z

372

Probe with integrated heater and thermocouple pack  

DOE Patents (OSTI)

A probe for measuring heat includes an elongate rod fitted within a sheath, and a plurality of annular recesses are formed on the surface of the rod in a spaced-apart relationship to form annular chambers that are resistant to heat flow. A longitudinal bore extends axially into the rod and within the cylinders defined by the annular chambers, and an integrated heater and thermocouple pack is dimensioned to fit within the bore. In construction, the integrated pack includes a plurality of wires disposed in electrical insulation within a sheath and a heater cable. These wires include one common wire and a plurality of thermocuple wires. The common wire is constructed of one type of conductive material while the thermocouple wires are each constructed of two types of materials so that at least one thermocouple junction is formed therein. All of the wires extend the length of the integrated pack and are connected together at their ends. The thermocouple wires are constructed to form thermocouple junctions proximate to each annular chamber for producing electromotive forces corresponding to the temperature of the rod within the annular chambers relative to outside the chambers. In the preferred embodiment, each thermocouple wire forms two thermocouple junctions, one junction being disposed within an annular chamber and the second junction being disposed outside of, but proximate to, the same annular chamber. In one embodiment two thermocouple wires are configured to double the sensitivity of the probe in one region.

McCulloch, Reg W. (Oak Ridge, TN); Dial, Ralph E. (Concord, TN); Finnell, Wilber K. R. (Kingston, TN)

1990-01-01T23:59:59.000Z

373

Probe with integrated heater and thermocouple pack  

DOE Patents (OSTI)

A probe for measuring heat includes an elongate rod fitted within a sheath, and a plurality of annular recesses are formed on the surface of the rod in a spaced-apart relationship to form annular chambers that are resistant to heat flow. A longitudinal bore extends axially into the rod and within the cylinders defined by the annular chambers, and an integrated heater and thermocouple pack is dimensioned to fit within the bore. In construction, the integrated pack includes a plurality of wires disposed in electrical insulation within a sheath and a heater cable. These wires include one common wire and a plurality of thermocouple wires. The common wire is constructed of one type of conductive material while the thermocouple wires are each constructed of two types of materials so that at least one thermocouple junction is formed therein. All of the wires extend the length of the integrated pack and are connected together at their ends. The thermocouple wires are constructed to form thermocouple junctions proximate to each annular chamber for producing electromotive forces corresponding to the temperature of the rod within the annular chambers relative to outside the chambers. In the preferred embodiment, each thermocouple wire forms two thermocouple junctions, one junction being disposed within an annular chamber and the second junction being disposed outside of, but proximate to, the same annular chamber. In one embodiment two thermocouple wires are configured to double the sensitivity of the probe in one region.

McCulloch, Reginald W. (Oak Ridge, TN); Dial, Ralph E. (Concord, TN); Finnell, Wilber K. R. (Kingston, TN)

1988-01-01T23:59:59.000Z

374

Design and Application of Solar Water Heater Intelligent Control System  

Science Conference Proceedings (OSTI)

Solar water heater intelligent control system is made up of four modules which are data acquisition module, single-chip control module, the implementation and regulation module and human- machine interaction module. The problems of automatic detection ... Keywords: Solar Water Heater, Hardware Design, Detection and Control

Yu Gui Yin

2009-10-01T23:59:59.000Z

375

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

The effect on water and gas usage from cross-flow betweencontrols have on water and gas usage over a large number ofsystems, and their water and gas usage. Hourly schedules for

Lutz, Jim

2012-01-01T23:59:59.000Z

376

Columbia Gas of Kentucky - Home Savings Rebate Program (Kentucky) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbia Gas of Kentucky - Home Savings Rebate Program (Kentucky) Columbia Gas of Kentucky - Home Savings Rebate Program (Kentucky) Columbia Gas of Kentucky - Home Savings Rebate Program (Kentucky) < Back Eligibility Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Water Heating Program Info State Kentucky Program Type Utility Rebate Program Rebate Amount Home Energy Audit: Free Forced Air Furnace: $400 Dual Fuel Furnace: $300 Tankless Water Heater: $300 Tank Water Heater: $200 Power Vent Water Heater: $250 Space Heater: $100 Provider Columbia Gas of Kentucky Columbia Gas of Kentucky offers rebates to residential customers for the purchase and installation of energy efficient appliances and equipment. Water heaters, furnaces and space heating equipment are available for cash

377

City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hot Water Heaters and Photovoltaic Systems Permit Requirements City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit Requirements Eligibility Commercial...

378

Energy Efficiency Design Options for Residential Water Heaters: Economic Impacts on Consumers  

E-Print Network (OSTI)

G. Rosenquist. 1998. WHAM: A Simplified Energy ConsumptionWater Heater Analysis Model (WHAM) calculation method, whichcharacteristics of water heaters, WHAM uses parameters from

Lekov, Alex

2011-01-01T23:59:59.000Z

379

Solar Water Heater Rebate Program (U.S. Virgin Islands) | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heater Rebate Program (U.S. Virgin Islands) Solar Water Heater Rebate Program (U.S. Virgin Islands) Eligibility Residential Savings For Heating & Cooling Solar Water...

380

Tankless Demand Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Demand Water Heater Basics Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Tankless Demand Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

382

Clark Public Utilities - Solar Water Heater Rebate | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Clark Public Utilities - Solar Water Heater Rebate Clark Public Utilities - Solar Water Heater Rebate Clark Public Utilities - Solar Water Heater Rebate < Back Eligibility Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount $500 Provider Clark PUD Clark Public Utilities offers a rebate of $500 to customers who install a solar water heating system. Customers must own the residence or business where the solar water heating system is installed and must have an electric water heater. In addition, Clark Public Utilities offers a [http://dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA29F&re=1&ee=1 loan program] for eligible solar water heater equipment. For additional information, call Energy Services at (360) 992-3355.

383

Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tri-County Electric Cooperative - Energy Efficient Water Heater Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate Program Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate Program < Back Eligibility Commercial Residential Savings Category Appliances & Electronics Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount $75 Provider Tri-County Electric Cooperative Tri-County Electric Cooperative offers a $75 rebate on the purchase of energy-efficient electric water heaters. The rebate is valid for new or replacement units which have an Energy Factor Rating of 0.90 or higher. The minimum tank size is 40 gallons, with a minimum 4,500 watt heating element. For validation purposes, a copy of the sales or installation receipt must accompany the [http://www.tcectexas.com/Forms/water%20heater%20rebate%20form.pdf

384

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate $600 Program Info State Florida Program Type Utility Rebate Program Rebate Amount 0.01 per BTU output Provider Clay Electric Co-op Clay Electric Cooperative (CEC) provides a rebate of $0.01 per BTU output to its residential members when they purchase qualified solar water heaters. This rebate is capped at 60,000 BTUs per system, or $600. Eligible solar water heaters can be either passive or active systems. The proposed solar system must meet Florida Solar Energy Center (FSEC) specifications and be installed by a contractor certified to install solar water heating

385

Performance test plan for a space station toluene heater tube  

DOE Green Energy (OSTI)

Sundstrand Energy Systems was awarded a contract to investigate the performance capabilities of a toluene heater tube integral to a heat pipe as applied to the Organic Rankine Cycle (ORC) solar dynamic power system for the Space Station. This heat pipe is a subassembly of the heat receiver. The heat receiver, the heat absorption component of the ORC solar dynamic power system, consists of forty liquid metal heat pipes located circumferentially around the heat receiver`s outside diameter. Each heat pipe contains a toluene heater, two thermal energy storage (TES) canisters and potassium. The function of the heater tube is to heat the supercritical toluene to the required turbine inlet temperature. During the orbit of the space station, the heat receiver and thereby the heat pipe and heater tube will be subjected to variable heat input. The design of the heater must be such that it can accommodate the thermal and hydraulic variations that will be imposed upon it.

Parekh, M.B. [Sundstrand Energy Systems, Rockford, IL (United States)

1987-10-01T23:59:59.000Z

386

Charlottesville Gas - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Charlottesville Gas - Residential Energy Efficiency Rebate Program Charlottesville Gas - Residential Energy Efficiency Rebate Program Charlottesville Gas - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Appliances & Electronics Water Heating Program Info State Virginia Program Type Utility Rebate Program Rebate Amount Programmable Thermostat: up to $100 Natural Gas Water Heater Conversion: $100 Provider City of Charlottesville Charlottesville Gas offers rebates to residential customers for purchasing and installing specified energy efficient equipment. Rebates and utility bill credits of up to $100 are available for installing new, energy efficient natural gas water heaters and programmable thermostats. Only customers which previously did not have natural gas water heating are

387

Experimental Study of the Floor Radiant Cooling System Combined with Displacement Ventilation  

E-Print Network (OSTI)

As a comfortable and energy-efficient air conditioning system, the application of floor radiant heating system is used increasingly greatly in the north of China. As a result, the feasibility of floor radiant cooling has gained more attention. To examine the thermodynamic performance of the floor radiant cooling system, we measured the operational conditions including the minimum floor surface temperature, the cooling capacity, and the indoor temperature field distribution under different outdoor temperatures in Beijing. Because the ground temperature changes with the mean temperature of the supplied and returned water and room temperature, the mean temperature of the supplied and retuned water was obtained. Finally, we analyzed the phenomenon of dewing and developed measures for preventing it. The dry air layer near the floor formed by a displacement ventilation system can effectively prevent dews on the surface of the floor in the wet and hot days in summer. In addition, for the sake of the displacement ventilation system, the heat transfer effect between floor and space is enhanced. Our analysis pointed out that floor radiant cooling system combined with displacement ventilation ensures good comfort and energy efficiency.

Ren, Y.; Li, D.; Zhang, Y.

2006-01-01T23:59:59.000Z

388

Appendix D Eligibility Criteria for Radiant Barriers Page D-1 2013 Residential Compliance Manual January 2014  

E-Print Network (OSTI)

shall meet specific eligibility and installation criteria to be modeled by any ACM and receive energy (stapled) to the bottom surface of the truss/rafter (top chord). A minimum air space shall be maintained of the radiant barrier and the top of the ceiling insulation to allow ventilation air to flow between the roof

389

The Clouds and the Earth's Radiant Energy System (CERES) Sensors and Preflight Calibration Plans  

Science Conference Proceedings (OSTI)

The Clouds and the Earth's Radiant Energy System (CERES) spacecraft sensors are designed to measure broadband earth-reflected solar shortwave (0.3–5 ”m) and earth-emitted longwave (5– > 100 ”m) radiances at the top of the atmosphere as part of ...

Robert B. Lee III; Bruce R. Barkstrom; G. Louis Smith; John E. Cooper; Leonard P. Kopia; R. Wes Lawrence; Susan Thomas; Dhirendra K. Pandey; Dominique A. H. Crommelynck

1996-04-01T23:59:59.000Z

390

Heat Pump Water Heater Performance in  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

searc searc e er tra A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida searc e er tra Heat Pump Water Heater Performance in Laboratory House Building America Technical Update 2013 ACI National Home Performance Conference April 29- 30 , 2013 Carlos J. Colon carlos@fsec.ucf.edu A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida Hot Water Systems (HWS) Laboratory FSEC Grounds, Florida (east coast) 2009 -Present (Currently fourth testing rotation) FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida

391

Evaluation of TANK Water Heater Simulation Model as Embedded in HWSim  

NLE Websites -- All DOE Office Websites (Extended Search)

TANK Water Heater Simulation Model as Embedded in HWSim TANK Water Heater Simulation Model as Embedded in HWSim Title Evaluation of TANK Water Heater Simulation Model as Embedded in HWSim Publication Type Report LBNL Report Number LBNL-5092E Year of Publication 2010 Authors Lutz, James D. Document Number LBNL-5092E Pagination 11 Date Published December 22 Publisher Lawrence Berkeley National Laboratory City Berkeley ISBN Number LBNL-5092E Abstract This report evaluates the hot water temperatures and flow rates as calculated by the combined HWSim and TANK simulation models. Notes This work was sponsored by the Gas Technology Institute (GTI) which is funded by the California Energy Commission, Public Interest Energy Research (PIER) Program, under Residential Water Heating Program Contract No. 500-08-060. This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231.

392

Development and Field Trial of Dimpled-Tube Technology for Chemical Industry Process Heaters  

SciTech Connect

Most approaches to increasing heat transfer rates in the convection sections of gas-fired process heaters involve the incorporation of fins, baffles, turbulizers, etc. to increase either the heat transfer surface area or turbulence or both. Although these approaches are effective in increasing the heat transfer rates, this increase is invariably accompanied by an associated increase in convection section pressure drop as well as, for heaters firing ‘dirty’ fuel mixtures, increased fouling of the tubes – both of which are highly undesirable. GTI has identified an approach that will increase heat transfer rates without a significant increase in pressure drop or fouling rate. Compared to other types of heat transfer enhancement approaches, the proposed dimpled tube approach achieves very high heat transfer rates at the lowest pressure drops. Incorporating this approach into convection sections of chemical industry fired process heaters may increase energy efficiency by 3-5%. The energy efficiency increase will allow reducing firing rates to provide the required heating duty while reducing the emissions of CO2 and NOx.

Yaroslav Chudnovsky; Aleksandr Kozlov

2006-10-12T23:59:59.000Z

393

The effect of location on the predicted performance of a heat pump water heater  

Science Conference Proceedings (OSTI)

Laboratory testing and field testing have shown that a heat pump water heater (HPWH) uses about half the electrical energy input that an electric resistance water heater does. However, since the HPWH extracts energy from the air in its environment, the question arises as to how this energy extraction would affect the house heating, ventilating, and air-conditioning (HVAC) system if the HPWH were located in a conditioned space of a household. A second question concerns the savings obtained by locating the HPWH in an unconditioned space such as a garage or basement. The effect of locating the HPWH in the conditioned spaces of houses with a high-performance heat pump as well as resistance- gas- and oil-heated houses with a high performance electric air conditioner was studied. All calculations were made on a desktop computer. Weather bin data and inlet water temperatures for each city were used to calcuate the energy consumption for the house first with a resistance water heater, and then with a HPWH. The difference between these values was used to calculate the performance factor (PF) of the HPWH. The HPWH will add to the house heating load in winter and lessen the house cooling load in summer.

Levins, W.P.

1982-01-01T23:59:59.000Z

394

FEMP Designated Product Assessment for Commercial Gas Water Heaters  

E-Print Network (OSTI)

Commission (CEC) Appliance Database. 9 This data set listsEnergy Commission Appliance Database's Advanced Search page

Lutz, Jim

2012-01-01T23:59:59.000Z

395

Energy Efficient Condensing Side-arm Gas Water Heater - Energy ...  

Hydrogen and Fuel Cell; Hydropower, Wave and ... thereby eliminating standby energy losses that occur when heat is transferred from the hot water to ...

396

The Impact of Blowing Agents on Residential Water Heater Performance  

NLE Websites -- All DOE Office Websites (Extended Search)

The Impact of Blowing Agents on Residential Water Heater Performance The Impact of Blowing Agents on Residential Water Heater Performance Title The Impact of Blowing Agents on Residential Water Heater Performance Publication Type Report LBNL Report Number LBNL-47352 Year of Publication 2001 Authors Lekov, Alexander B., James D. Lutz, Camilla Dunham Whitehead, and James E. McMahon Document Number LBNL-47352 Date Published January 12 Abstract The National Appliance Energy Conservation Act of 1987 (NAECA) requires the U.S. Department of Energy (DOE) to consider amendments to the energy conservation standards to increase energy efficiency in residential water heaters. A driving force affecting efficiency is the ozone-depletion regulation regarding blowing agents for insulation in all water heater fuel types. This paper presents results of cost and efficiency impacts of three potential blowing agents. Residential water heaters are typically insulated with polyurethane foam in the space between the tank and the jacket. Currently, water heater manufacturers use HCFC-141b, an ozone-depleting substance, as a blowing agent. After 2003, as a result of the Montreal Protocol (1993), manufacturers must use blowing agents that do not deplete the ozone layer. The analysis presented in this paper considers three replacement candidates, HFC-245fa, HFC-134a, and cyclopentane by comparing their efficiency and cost effectiveness when applied to water heater insulation. This analysis used computer simulation models and other analytical methods to investigate the efficiency improvements due to different design options, when alternative blowing agents are applied. The calculations were based on the DOE test procedure for residential water heaters. The analysis used average manufacturer, retailer, and installer costs to calculate the total consumer costs. Consumer operating expenses were calculated based on modeled energy consumption under test procedure conditions and U.S. average energy prices. With this information, a cost-efficiency relationship was developed to show the average manufacturer and consumer cost to achieve increased efficiency.

397

MassSAVE (Gas) - Residential Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

MassSAVE (Gas) - Residential Rebate Program MassSAVE (Gas) - Residential Rebate Program MassSAVE (Gas) - Residential Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Other Appliances & Electronics Water Heating Program Info Start Date 1/1/2012 Expiration Date 12/31/2013 State Massachusetts Program Type Utility Rebate Program Rebate Amount Warm Air Furnaces with Electronic Commutated Motor (ECM): $300-$450 Forced Hot Water Boilers: $1,000-$1500 Programmable/Wi-Fi Thermostats: $25-$100 Indirect Water Heater: $400 Tankless On-Demand Water Heater: $500 or $800 Indirect Water Heater: $400 Condensing Gas Water Heaters: $500 Combined Boiler/Water Heating Unit: $1,200 Storage Water Heater: $100 After-Market Boiler Reset Controls: $225

398

Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate Program Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Ventilation Manufacturing Heat Pumps Appliances & Electronics Water Heating Program Info State Georgia Program Type Utility Rebate Program Rebate Amount In-Home Energy Evaluation Program Windows: $500 Duct Repair: $500 Rehabilitation Work: $250 HVAC Replacement: $250/unit HVAC Tune-up: $150/unit Insulation: $500 Water Heater and Pipe Insulation: $50 Air Sealing: $500 Energy Right Program

399

Gas  

Science Conference Proceedings (OSTI)

... Implements a gas based on the ideal gas law. It should be noted that this model of gases is niave (from many perspectives). ...

400

Efficiency Maine Business Programs (Unitil Gas) - Commercial...  

Open Energy Info (EERE)

Furnaces; 1000 Condensing Boilers: 1500 - 4500 Non-Condensing Boilers: 750-3,000 Steam Boiler: 800 or 1MBtuh Infrared Unit Heaters: 500 Natural Gas Warm-Air Unit...

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Washington Gas- Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Washington Gas provides a number of rebates to residential customers who utilize energy efficient equipment and measures in the home. Rebate are available for tankless water heaters, storage (tank)...

402

Southwest Gas Corporation - Residential and Builder Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heater: 450 Natural Gas Clothes Dryer: 30 Windows: 0.95sq ft Attic Insulation: 0.15sq ft Floor Insulation: 0.30sq ft Builders Energy Star Certified Home: 450...

403

Atmos Energy (Gas) - Residential Efficiency Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

(Gas) - Residential Efficiency Program (Gas) - Residential Efficiency Program Atmos Energy (Gas) - Residential Efficiency Program < Back Eligibility Low-Income Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Sealing Your Home Appliances & Electronics Water Heating Windows, Doors, & Skylights Program Info State Iowa Program Type Utility Rebate Program Rebate Amount Furnace lowest $250, $325, or $400 Boiler: $150 or $400 Condensing Water Heater: $300 Storage Water Heater: $75 Tankless Water Heater: $300 Provider Energy Federation Incorporated '''As of August 1, 2012, Iowa energy efficiency programs are offered by Liberty Utilities. ''' Atmos Energy provides rebates for residential natural gas heating equipment through their High Efficiency Rebate Program. When Atmos Receives the

404

Questar Gas - Residential Energy Efficiency Rebate Programs | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Maximum Rebate Maximum Rebate Limit of two rebates per appliance type Program Info Start Date 3/1/2011 State Utah Program Type Utility Rebate Program Rebate Amount Gas Furnace: $200 - $400 Gas Storage Water Heater: $50-$100 Gas Condensing Water Heater: $350 Gas Boiler: $400 -$600 Tankless Gas Water Heater: $350 Clothes Washer: $50 Windows: $0.95/sq. ft. Insulation (Wall): $0.30/sq. ft. Insulation (Floor): $0.20/sq. ft. Insulation (Attic): $0.07 - $0.25/sq. ft. Duct Sealing/Insulation: $100 + $5.25/ln. ft. Air Sealing: $100 + $.20/sq. ft. Programmable Thermostat: $30 In-Home Energy Audit: Discounted to $25 Provider Questar Gas Questar Gas provides rebates for energy efficient appliances and heating equipment, and certain weatherization measures through the ThermWise program. This equipment includes clothes washers, water heaters, furnaces,

405

Solar Water Heaters and the Economy | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heaters and the Economy Solar Water Heaters and the Economy Solar Water Heaters and the Economy July 11, 2012 - 11:59am Addthis Ernie Tucker Editor, National Renewable Energy Laboratory These are the days of hot sun and mortgage refinance frenzy. Somehow, they've both combined in my mind to make me ponder the economics of a solar water heater. Because the sun's been beating down on our garden hose, the initial flush of water can be very hot. The warm spray reminded me of the times on camping trips when we'd bring along a portable solar shower -- essentially a black plastic bag with a tube and shower nozzle -- for bathing. While not an endless supply (perhaps 10 gallons), it was a very enjoyable luxury. Of course, it assumes that there's plenty of sunshine, but if so -- voila -- a

406

Grays Harbor PUD - Solar Water Heater Loan | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heater Loan Solar Water Heater Loan Grays Harbor PUD - Solar Water Heater Loan < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate not specified Program Info State District of Columbia Program Type Utility Loan Program Rebate Amount not specified Provider Grays Harbor PUD Since October 2001, Grays Harbor PUD has offered a low-interest loan program (currently 4.0%) for the installation of solar water heaters. Loans are available for the installation of solar collectors of 40 square feet or more. The loans are provided through local lenders, with interest subsidized by the PUD. Only customers who currently use electricity for hot water are eligible. Pre-approval is required for this loan and loan amounts are determined on a case-by-case basis.

407

New Braunfels Utilities - Residential Solar Water Heater Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New Braunfels Utilities - Residential Solar Water Heater Rebate New Braunfels Utilities - Residential Solar Water Heater Rebate Program New Braunfels Utilities - Residential Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount $0.265/kWh Provider New Braunfels Utilities New Braunfels Utilities offers a rebate for residential customers who purchase and install solar water heating systems on eligible homes. A rebate of the equivalent of $0.265 per kWh is available to these customers. The maximum rebate amount is $900 for participating customers. Applicants must have an active residential electric service account with NBU in order to be eligible. Solar water heaters must preheat water for an electric

408

FS: heat pump water heaters | The Better Buildings Alliance  

NLE Websites -- All DOE Office Websites (Extended Search)

Food Service » Install a heat pump Food Service » Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specificat Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specification The Food Service team developed a Commercial Heat Pump Water Heater Specification that can be used to reduce water heating energy by 70%. An older, electric resistance water heater (operated in a building with a hot water demand of 500 gallons a day) can cost more than $3,500 each year

409

Solar Water Heaters and the Economy | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heaters and the Economy Water Heaters and the Economy Solar Water Heaters and the Economy July 11, 2012 - 11:59am Addthis Ernie Tucker Editor, National Renewable Energy Laboratory These are the days of hot sun and mortgage refinance frenzy. Somehow, they've both combined in my mind to make me ponder the economics of a solar water heater. Because the sun's been beating down on our garden hose, the initial flush of water can be very hot. The warm spray reminded me of the times on camping trips when we'd bring along a portable solar shower -- essentially a black plastic bag with a tube and shower nozzle -- for bathing. While not an endless supply (perhaps 10 gallons), it was a very enjoyable luxury. Of course, it assumes that there's plenty of sunshine, but if so -- voila -- a warm and sudsy campsite clean-up is possible.

410

Grays Harbor PUD - Solar Water Heater Rebate | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Grays Harbor PUD - Solar Water Heater Rebate Grays Harbor PUD - Solar Water Heater Rebate Grays Harbor PUD - Solar Water Heater Rebate < Back Eligibility Commercial Industrial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount $600 Provider Grays Harbor PUD Since October 2001, Grays Harbor PUD has offered a rebate program for the installation of solar water heaters. Rebates of $600 are available for the installation of solar collectors of 40 square feet or more. Only customers who currently use electricity for hot water are eligible. This rebate is available on a case-by-case basis, so you must contact the utility in order to take advantage of it. Customers may choose a [http://dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA09F&re=1&ee=1

411

List of Water Heaters Incentives | Open Energy Information  

Open Energy Info (EERE)

Heaters Incentives Heaters Incentives Jump to: navigation, search The following contains the list of 973 Water Heaters Incentives. CSV (rows 1-500) CSV (rows 501-973) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility Nonprofit Schools State Government Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Room Air Conditioners Yes AEP Public Service Company of Oklahoma - Residential Efficiency Rebate Program (Oklahoma) Utility Rebate Program Oklahoma Residential Building Insulation

412

Savings Project: Insulate Your Water Heater Tank | Department...  

NLE Websites -- All DOE Office Websites (Extended Search)

Your Water Heater Tank Addthis Project Level medium Energy Savings 20-45 annually Time to Complete 1.5 hours Overall Cost 30 Insulate your hot water tank to save energy and...

413

Energy test method development for electric heat pump water heaters  

SciTech Connect

Modifications are proposed for the current US Department of Energy test procedures for water heaters in order to make them applicable to electric heat pump water heaters. The modifications are in the areas of definitions and technical procedures. The latter include the test conditions, test procedures and measurements, and calculations. Reasons for making these modifications and laboratory test data are provided to support the modifications in the technical procedures. The main modifications include: (1) lowering the water supply temperature from 70/sup 0/F to 55/sup 0/F, (2) lowering the tank thermostat setting from 160/sup 0/F to 145/sup 0/F to maintain the same 90/sup 0/F temperature rise, (3) measuring the power input instead of using the nameplate rating as in the case for an electric water heater, and (4) measuring the recovery efficiency instead of calculating it by using the standby losses in the case for an electric water heater.

Wan, C.A.

1980-01-01T23:59:59.000Z

414

New Home Buyer Solar Water Heater Trade-Off Study  

DOE Green Energy (OSTI)

This report details the results of a research conducted in 1998 and 1999 and outlines a marketing deployment plan designed for businesses interested in marketing solar water heaters in the new home industry.

Symmetrics Marketing Corporation

1999-08-18T23:59:59.000Z

415

An Overview of the New Residential Water Heater Efficiency Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

An Overview of the New Residential Water Heater Efficiency Standards Speaker(s): Alex Lekov Date: April 26, 2010 - 12:00pm Location: 90-3122 DOE issued new standards for...

416

Heat Pump Water Heaters and American Homes: A Good Fit?  

NLE Websites -- All DOE Office Websites (Extended Search)

can be cost effective in all regionsfor most single family homes, especially when the water heater is not installed in a conditioned space. HPWHs are not cost effective for most...

417

Tankless Coil and Indirect Water Heaters | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

as it flows through a heating coil or heat exchanger installed in a main furnace or boiler. Tankless coil water heaters are most efficient during cold months when the heating...

418

Carbon Dioxide-Based Heat Pump Water Heater Research Project  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy is currently conducting research into carbon dioxide (CO2) heat pump water heaters. This project will employ innovative techniques to adapt water heating technology to...

419

Burbank Water and Power - Solar Water Heater Rebate Program ...  

Open Energy Info (EERE)

Burbank Water and Power - Solar Water Heater Rebate Program (California) No revision has been approved for this page. It is currently under review by our subject matter experts. No...

420

Marshall Municipal Utilities- Solar Thermal Water Heater Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Marshall Municipal Utilities (MMU) offers residential customers rebates for installing a ENERGY STAR Solar Thermal Water Heater. Rebates are based on the size of the system; MMU offers $20 per...

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Temperature limited heater utilizing non-ferromagnetic conductor  

SciTech Connect

A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.

Vinegar; Harold J. (Bellaire, TX), Harris; Christopher Kelvin (Houston, TX)

2012-07-17T23:59:59.000Z

422

Energy conservation for household refrigerators and water heaters  

Science Conference Proceedings (OSTI)

An energy conservation arrangement for household refrigerators and water heaters, in which the source of cold water to the hot water heater is divided and part is caused to flow through and be warmed in the condenser of the refrigerator. The warmed water is then further heated in the oil cooling loop of the refrigerator compressor, and proceeds then to the top of the hot water tank.

Speicher, T. L.

1984-12-11T23:59:59.000Z

423

A comprehensive review of market research on solar water heaters  

DOE Green Energy (OSTI)

This is the second report of a four-task project to develop a marketing plan designed for businesses interested in marketing solar water heaters in the new home industry. The objective of this task is to identify key elements in previous studies on the marketing of solar water heaters in the new home industry. This review includes studies performed by FOCUS Marketing Services, the National Association of Home Builders Research Center, Symmetrics Marketing Corporation, and the California Energy Commission.

Ghent, P.; Keller, C.

1999-11-01T23:59:59.000Z

424

Twilight Irradiance Reflected by the Earth Estimated from Clouds and the Earth's Radiant Energy System (CERES) Measurements  

Science Conference Proceedings (OSTI)

The upward shortwave irradiance at the top of the atmosphere when the solar zenith angle is greater than 90° (twilight irradiance) is estimated from radiance measurements by the Clouds and the Earth's Radiant Energy System (CERES) instrument on ...

Seiji Kato; Norman G. Loeb

2003-08-01T23:59:59.000Z

425

Estimation of Surface Energy Balance from Radiant Surface Temperature and NOAA AVHRR Sensor Reflectances over Agricultural and Native Vegetation  

Science Conference Proceedings (OSTI)

A model is developed to evaluate surface heat flux densities using the radiant surface temperature and red and near-infrared reflectances from the NOAA Advanced Very High Resolution Radiometer sensor. Net radiation is calculated from an empirical ...

Huang Xinmei; T. J. Lyons; R. C. G. Smith; J. M. Hacker; P. Schwerdtfeger

1993-08-01T23:59:59.000Z

426

Clouds and the Earth''s Radiant Energy System (CERES) Algorithm Theoretical Basis Document. Volume I-Overviews (Subsystem 0)  

Science Conference Proceedings (OSTI)

The theoretical bases for the Release 1 algorithms that will be used to process satellite data for investigation of the Clouds and the Earth''s Radiant Energy System (CERES) are described. The architecture for software implementation of the methodologies ...

Team CERES Science

1995-12-01T23:59:59.000Z

427

Determining Benefits and Costs of Improved Water Heater Efficiencies  

NLE Websites -- All DOE Office Websites (Extended Search)

Determining Benefits and Costs of Improved Water Heater Efficiencies Determining Benefits and Costs of Improved Water Heater Efficiencies Title Determining Benefits and Costs of Improved Water Heater Efficiencies Publication Type Report LBNL Report Number LBNL-45618 Year of Publication 2000 Authors Lekov, Alexander B., James D. Lutz, Xiaomin Liu, Camilla Dunham Whitehead, and James E. McMahon Document Number LBNL-45618 Date Published May 4 Abstract Economic impacts on individual consumers from possible revisions to U.S. residential water heater energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a water heater and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers are significant. At the efficiency level examined in this paper, 35% of households with electric water heaters experience LCC savings, with an average savings of $106, while 4% show LCC losses, with an average loss of $40 compared to a pre-standard LCC average of $2,565. The remainder of the population (61%) are largely unaffected.

428

Questar Gas - Home Builder Gas Appliance Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Questar Gas - Home Builder Gas Appliance Rebate Program Questar Gas - Home Builder Gas Appliance Rebate Program Questar Gas - Home Builder Gas Appliance Rebate Program < Back Eligibility Construction Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Construction Commercial Weatherization Design & Remodeling Appliances & Electronics Water Heating Program Info Start Date 7/1/2009 State Wyoming Program Type Utility Rebate Program Rebate Amount Energy Star Home Certification: $500 Storage Water Heater: $50 Tankless Water Heater: $300 Furnace: $300 Boiler: $400 Provider Questar Gas Questar Gas provides incentives for home builders to construct energy efficient homes. Rebates are provided for both energy efficient gas equipment and whole home Energy Star certification. All equipment and

429

Water heater with an improved thermostat mounting and a method of making such water heaters  

Science Conference Proceedings (OSTI)

An improvement in an electric water heater is described comprising: a non-metallic tank, a cold water inlet, a hot water outlet, an electrical heating means adapted to heat a body of water contained in the tank and a thermostat having a sensing face with a given area controlling the flow of electric current to the heating means, the improvement comprising a thermally conductive thermostat mounting plate having a surface area substantially larger than the sensing face given area in direct contact with the tank and a thermostat retention means releasably holding the thermostat in contact with the thermostat mounting plate.

Moore, H.J.; Deneau, M.E.

1993-06-15T23:59:59.000Z

430

Mounting assembly for heater thermostat control  

Science Conference Proceedings (OSTI)

This patent describes an assembly for mounting a thermostat control on the outer wall of a heater tank including an external spud in which a heating element is mounted. The mounting assembly comprises: a first bracket made from a spring material and including a body having an opening adapted to lockingly fit over the tank spud. The first bracket further includes a pair of laterally-spaced legs extending from the body and having a bent upper end portion adapted to apply spring pressure toward the tank outer wall when the first bracket is locked on the tank spud. Each of the legs includes in the upper end portion an elongated slot having an upper end; a second bracket carrying the thermostat control and having a pair of laterally -spaced, upstanding ears adapted to fit beneath the upper end portions of the legs. Each of the ears includes a nib received in a slot for interlocking the first and the second brackets and having an upper edge adapted to engage the upper end of the slot and cooperate therewith to urge the thermostat control into firmer contact with the tank outer wall in response to upward vertical movement of the second bracket relative to the first bracket; and the assembly further characterized by a retaining lip on the first bracket, the lip located between the legs and positioned to bear against the end wall of the thermostat control when the parts are in assembled position and an outward horizontal load is applied.

Murphy, M.A.

1987-04-14T23:59:59.000Z

431

Light-weight radioisotope heater impact tests  

SciTech Connect

The light-weight radioisotope heater unit (LWRHU) is a {sup 238}PuO{sub 2}-fueled heat source designed to provide one thermal watt in each of various locations on a spacecraft. Los Alamos National Laboratory designed, fabricated, and safety tested the LWRHU. The heat source consists of a hot-pressed {sup 238}PuO{sub 2} fuel pellet, a Pt-30Rh vented capsule, a pyrolytic graphite insulator, and a fineweave-pierced fabric graphite aeroshell assembly. To compare the performance of the LWRHUs fabricated for the Cassini mission with the performance of those fabricated for the Galileo mission, and to determine a failure threshold, two types of impact tests were conducted. A post-reentry impact test was performed on one of 180 flight-quality units produced for the Cassini mission and a series of sequential impact tests using simulant-fueled LWRHU capsules were conducted respectively. The results showed that deformation and fuel containment of the impacted Cassini LWRHU was similar to that of a previously tested Galileo LWRHU. Both units sustained minimal deformation of the aeroshell and fueled capsule; the fuel was entirely contained by the platinum capsule. Sequential impacting, in both end-on and side-on orientations, resulted in increased damage with each subsequent impact. Sequential impacting of the LWRHU appears to result in slightly greater damage than a single impact at the final impact velocity of 50 m/s.

Reimus, M.A.H.; Rinehart, G.H.; Herrera, A. [and others

1998-12-31T23:59:59.000Z

432

Solar heater and roof attachment means  

Science Conference Proceedings (OSTI)

A solar heater includes an elongated solar collector having two fixedly connected solar panels of highly heat conductive material supported by a roof clamp on a shingled roof. The bottom edges of each of the solar panels include upturned gutter portions. One form of roof clamp for shingled roofs includes a J-shape shingle clamp member having a clamp bolt extending therethrough, and a solar collector clamp member assembled on the bolt and clamped to the bottom gutter portions of the solar panels. A bottom plate of the J-shape clamp member is slid under a shingle of a first shingle course and under a shingle of a second upper shingle course to carry the bolt into the top of the gap between adjacent shingle portions of the first course and to position a top plate of the shingle clamp member over parts of the shank portions of the first course and over a part of the one shingle of the second course. A clamp nut clamps the collector clamp member and the shingle clamp member firmly to the contacted shingles.

Howe, G.L.; Koutavas, S.G.

1984-02-21T23:59:59.000Z

433

Vaporization, dispersion, and radiant fluxes from LPG spills. Final technical report  

SciTech Connect

Both burning and non-burning spills of LPG (primarily propane) were studied. Vaporization rates for propane spills on soil, concrete, insulating concrete, asphalt, sod, wood, and polymer foams were measured. Thermal conductivity, heat transfer coefficients, and steady state vaporization rates were determined. Vapor concentrations were measured downwind of open propane pools and a Gaussian dispersion model modified for area sources provided a good correlation of measured concentrations. Emitted and incident radiant fluxes from propane fires were measured. Simplified flame radiation models were adequate for predicting radiant fluxes. Tests in which propane was sprayed into the air showed that at moderately high spray rates all the propane flashed to vapor or atomized; no liquid collected on the ground.

1982-05-01T23:59:59.000Z

434

Numerical Simulation of Thermal Performance of Floor Radiant Heating System with Enclosed Phase Change Material  

E-Print Network (OSTI)

In the present paper, a kind of enclosed phase change material (PCM) used in solar and low-temperature hot water radiant floor heating is investigated. On the basis of obtaining the best performance of PCM properties, a new radiant heating structure of the energy storage floor is designed,which places heat pipes in the enclosed phase change material (PCM) layer, without concrete in it. The PCM thermal storage time is studied in relation to the floor surface temperature under different low-temperature hot water temperatures. With the method of enthalpy , the PCM thermal storage time is studied under different supply water temperatures, supply water flows, distances between water wipe in the floor construction, floor covers and insulation conditions.

Qiu, L.; Wu, X.

2006-01-01T23:59:59.000Z

435

NSTAR (Gas) - Commercial Energy Efficiency Programs | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NSTAR (Gas) - Commercial Energy Efficiency Programs NSTAR (Gas) - Commercial Energy Efficiency Programs NSTAR (Gas) - Commercial Energy Efficiency Programs < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Other Appliances & Electronics Commercial Weatherization Water Heating Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Forced Hot Water Boilers: $500-$15,000 Boiler Reset Controls: $225 Condensing Unit or Water Heater: $500 On-Demand Unit Heater: $1000 or $1600 Warm Air Furnaces: $400-$800 Indirect Water Heater/Boiler: $400 Tankless Water Heater: $500 or $800 Storage Water Heaters: $50 or $100 Low Intensity Infrared Heating Units: $500 High Efficiency Cooking Equipment: up to $1,000 Steam Traps: $25 Programmable Thermostats: $25

436

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

the elimination of the standby losses common to gas storageflow rates. Eliminating the standby heat loss results in ais used to account for standby losses. Although storage

Lutz, Jim

2012-01-01T23:59:59.000Z

437

Study of thermosiphon and radiant panel passive heating systems for metal buildings  

DOE Green Energy (OSTI)

A study of passive-heating systems appropriate for use on metal buildings is being conducted at Los Alamos National Laboratory for the Naval Civil Engineering Laboratory, Port Hueneme, California. The systems selected for study were chosen on the basis of their appropriateness for retrofit applications, although they are also suitable for new construction: simple radiant panels that communicate directly with the building interior and a backflow thermosiphon that provides heat indirectly.

Biehl, F.A.; Schnurr, N.M.; Wray, W.O.

1983-01-01T23:59:59.000Z

438

Combined Operation of Solar Energy Source Heat Pump, Low-vale Electricity and Floor Radiant System  

E-Print Network (OSTI)

Today energy sources are decreasing and saving energy conservation becomes more important. Therefore, it becomes an important investigative direction how to use reproducible energy sources in the HVAC field. The feasibility and necessity of using solar energy, low-vale electricity as heat sources in a floor radiant system are analyzed. This paper presents a new heat pump system and discusses its operational modes in winter.

Liu, G.; Guo, Z.; Hu, S.

2006-01-01T23:59:59.000Z

439

Energy measurements of single-family houses with attics containing radiant barriers  

Science Conference Proceedings (OSTI)

Radiant barriers were tested in attics of three unoccupied research houses which are located near Knoxville, Tennessee. The prime purpose of the testing was to determine the interaction, if any, between two types of radiant barriers, horizontal (barrier laid on top of attic insulation) and truss (barrier attached to underside of roof trusses), and three levels of fiberglass-batt attic insulation, R-11, R-19, and R-30. Testing of radiant barriers with R-19 fiberglass-batt attic insulation was done at the houses in the summer of 1985 and in the winter of 1985-86. The R-11 and R-30 testing was done in the summer of 1986. These results showed that horizontal barriers were more effective than truss barriers in reducing house cooling and heating loads. The summer of 1986 testing showed that increasing the attic insulation from R-11 to R-30 reduced the house cooling load (Btu) by approximately 16%. Adding a horizontal barrier to R-11 also reduced the cooling load compared to R-11 with no barrier by about 16%, while a truss barrier reduced it by 11%. A horizontal barrier with R-30 only reduced the cooling load by 2% compared to R-30 with no barrier, while an increase in the cooling load of 0.7% was measured with a truss barrier and R-30. Radiant barriers were not effective in reducing house cooling loads when R-30 attic insulation was present. The results from the summer of 1985 were integrated into the latest work through the use of a modeling effort using the building load simulation program, DOE-2.1B. This showed that R-19 insulation in conjunction with a horizontal barrier was (for Knoxville) the most effective barrier/insulation combination and could reduce the house cooling load by 25.1% compared to R-11 with no barrier.

Levins, W.P.; Karnitz, M.A.

1987-01-01T23:59:59.000Z

440

Water augmented indirectly-fired gas turbine systems and method  

SciTech Connect

An indirectly-fired gas turbine system utilizing water augmentation for increasing the net efficiency and power output of the system is described. Water injected into the compressor discharge stream evaporatively cools the air to provide a higher driving temperature difference across a high temperature air heater which is used to indirectly heat the water-containing air to a turbine inlet temperature of greater than about 1,000.degree. C. By providing a lower air heater hot side outlet temperature, heat rejection in the air heater is reduced to increase the heat recovery in the air heater and thereby increase the overall cycle efficiency.

Bechtel, Thomas F. (Lebanon, PA); Parsons, Jr., Edward J. (Morgantown, WV)

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Water augmented indirectly-fired gas turbine system and method  

DOE Patents (OSTI)

An indirectly-fired gas turbine system utilizing water augmentation for increasing the net efficiency and power output of the system is described. Water injected into the compressor discharge stream evaporatively cools the air to provide a high driving temperature difference across a high temperature air heater which is used to indirectly heat the water-containing air to a turbine inlet temperature of greater than about 1000{degrees}C. By providing a lower air heater hot side outlet temperature, heat rejection in the air heater is reduced to increase the heat recovery in the air heater and thereby increase the overall cycle efficiency.

Bechtel, T.F.; Parsons, E.J. Jr.

1991-12-31T23:59:59.000Z

442

Water augmented indirectly-fired gas turbine system and method  

DOE Patents (OSTI)

An indirectly-fired gas turbine system utilizing water augmentation for increasing the net efficiency and power output of the system is described. Water injected into the compressor discharge stream evaporatively cools the air to provide a high driving temperature difference across a high temperature air heater which is used to indirectly heat the water-containing air to a turbine inlet temperature of greater than about 1000[degrees]C. By providing a lower air heater hot side outlet temperature, heat rejection in the air heater is reduced to increase the heat recovery in the air heater and thereby increase the overall cycle efficiency.

Bechtel, T.F.; Parsons, E.J. Jr.

1991-01-01T23:59:59.000Z

443

Effect of Radiant Barrier Technology on Summer Attic Heat Load in South Texas  

E-Print Network (OSTI)

The objective of the study was to experimentally evaluate the performance of radiant barriers in single-family occupied housing units in South Texas. Ceiling heat fluxes, attic air temperatures, indoor air temperatures, ambient air temperatures. roof temperatures, and solar radiation were measured. Results of the radiant barrier experiment using two side-by-side 600 ft2 units are presented. Attic fiberglass insulation of nominal R-11 was installed in the two apartments when the units were last remodeled in 1974. The test houses responded similarly to weather variations, that is, attic temperature and heat flux profiles were similar in magnitude prior to the retrofit. Residents of the housing units were asked to set the thermostats at 76°F. Data were analyzed for periods of time which had the greatest attic temperatures (11 a.m. - 11 p.m.) and for which the indoor temperature differences were less than 1 percent. The results showed that radiant barriers reduced ceiling heat loads (on daily basis) by an average of 60 percent.

Ashley, R.; Garcia, O.; Medina, M. A.; Turner, W. D.

1994-01-01T23:59:59.000Z

444

Peoples Gas - Residential Rebate Program (Illinois) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Peoples Gas - Residential Rebate Program (Illinois) Peoples Gas - Residential Rebate Program (Illinois) Peoples Gas - Residential Rebate Program (Illinois) < Back Eligibility Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Cooling Appliances & Electronics Water Heating Maximum Rebate 100% of project cost Program Info Expiration Date 05/31/2013 State Illinois Program Type Utility Rebate Program Rebate Amount Furnace: $300 -$500 Boiler: varies, depending on size and efficiency Boiler Controls: $100/unit Complete HVAC System Replacement: $650 - $1,000 Water Heater (Tankless): $450 Water Heater (Indirect): $275 Water Heater (Storage Tank): $100 Attic Insulation: $0.10/sq ft Programmable Thermostat: $50

445

Atmos Energy - Residential Natural Gas and Weatherization Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

- Residential Natural Gas and Weatherization - Residential Natural Gas and Weatherization Efficiency Program Atmos Energy - Residential Natural Gas and Weatherization Efficiency Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Sealing Your Home Construction Commercial Weatherization Design & Remodeling Appliances & Electronics Water Heating Program Info State Missouri Program Type Utility Rebate Program Rebate Amount Comprehensive Upgrades (Energize Homes): Up to $5,00 Furnace: $200-$300 Boiler: $200-$300 Combination Boiler/Water Heater: $450 Storage Water Heater: $50-$125 Tankless/Condensing Water Heater: $200 Programmable Thermostat $25 Provider Energy Federation Incorporated '''As of August 1, 2012, Missouri energy efficiency programs are offered by

446

Berkshire Gas - Commercial Energy Efficiency Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Berkshire Gas - Commercial Energy Efficiency Rebate Program Berkshire Gas - Commercial Energy Efficiency Rebate Program Berkshire Gas - Commercial Energy Efficiency Rebate Program < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Manufacturing Other Sealing Your Home Ventilation Appliances & Electronics Commercial Lighting Lighting Water Heating Windows, Doors, & Skylights Maximum Rebate See Program Website Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Custom: 50% of cost Furnaces: $500 - $800 Condensing Unit Heaters: $750 Infrared Heaters: $750 Condensing Boilers: $1,000 - $10,000 Boiler Reset Controls: $225 Integrated Water Heater/Condensing Boilers: $1,200

447

Heat Pump Water Heaters and American Homes: A Good Fit?  

SciTech Connect

Heat pump water heaters (HPWHs) are over twice as energy-efficient as conventional electric resistance water heaters, with the potential to save substantial amounts of electricity. Drawing on analysis conducted for the U.S. Department of Energy's recently-concluded rulemaking on amended standards for water heaters, this paper evaluates key issues that will determine how well, and to what extent, this technology will fit in American homes. The key issues include: 1) equipment cost of HPWHs; 2) cooling of the indoor environment by HPWHs; 3) size and air flow requirements of HPWHs; 4) performance of HPWH under different climate conditions and varying hot water use patterns; and 5) operating cost savings under different electricity prices and hot water use. The paper presents the results of a life-cycle cost analysis of the adoption of HPWHs in a representative sample of American homes, as well as national impact analysis for different market share scenarios. Assuming equipment costs that would result from high production volume, the results show that HPWHs can be cost effective in all regions for most single family homes, especially when the water heater is not installed in a conditioned space. HPWHs are not cost effective for most manufactured home and multi-family installations, due to lower average hot water use and the water heater in the majority of cases being installed in conditioned space, where cooling of the indoor environment and size and air flow requirements of HPWHs increase installation costs.

Franco, Victor; Lekov, Alex; Meyers, Steve; Letschert, Virginie

2010-05-14T23:59:59.000Z

448

Heat Pump Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heater Basics Water Heater Basics Heat Pump Water Heater Basics August 19, 2013 - 2:59pm Addthis Illustration of a heat pump water heater, which looks like a tall cylinder with a small chamber on top and a larger one on the bottom. In the top chamber are a fan, a cylindrical compressor, and an evaporator that runs along the inside of the chamber. Jutting out from the exterior of the bottom chamber is a temperature and pressure relief valve. This valve has a tube called a hot water outlet attached to the top. Below the valve is the upper thermostat, a small square outside the cylinder that is attached to a curved tube inside the heater. Resistance elements run from the upper thermostat to the similarly shaped lower thermostat. Below the lower thermostat is a drain valve with a cold water inlet attached to the top. Inside the cylinder is an anode, a series of thin tubes running through the bottom chamber to a coiled tube called a condenser. Insulation runs along the inside of the cylinder.

449

Electric Tankless Water Heater (TWH) Performance Evaluation and System Compatibility Report  

Science Conference Proceedings (OSTI)

The Instantaneous Water Heater or Tankless Water Heater (TWH) or Demand Water Heater is designed to provide hot water on demand without a storage tank. Tank water heaters require energy to maintain the water temperature in the tank when not in demand. In tank water heaters, due to the specific heat of the water, the thermal time constant of the water heater will not allow it to supply hot water at the same rate as it is used, hence the use of the tank, storing hot water for instant availability. In the e...

2005-12-22T23:59:59.000Z

450

Columbia Gas of Virginia - Home Savings Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbia Gas of Virginia - Home Savings Rebate Program Columbia Gas of Virginia - Home Savings Rebate Program Columbia Gas of Virginia - Home Savings Rebate Program < Back Eligibility Multi-Family Residential Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Water Heating Windows, Doors, & Skylights Program Info State Virginia Program Type Utility Rebate Program Rebate Amount Energy Star Gas Storage Water Heater: $50 Energy Star Gas Tankless Water Heater: $300 High Efficiency Gas Furnace: $300 High Efficiency Windows (Replacement): $1/sq. ft. Attic and Floor Insulation (Replacement): $0.30/sq. ft. Duct Insulation (Replacement): $200 - $250/site Provider Columbia Gas of Virginia

451

Efficient Low-Lift cooling with Radiant Distribution, Thermal Storage and Variable-Speed Chiller Controls Part II: Annual Energy Use and Savings  

DOE Green Energy (OSTI)

This paper evaluates the potential cooling efficiency improvements to be gained by integrating radiant cooling, cool storage, and variable-speed compressor and transport motor controls.

Armstrong, Peter; Jiang, Wei; Winiarski, David W.; Katipamula, Srinivas; Norford, L. K.

2009-03-31T23:59:59.000Z

452

Savings Project: Insulate Your Water Heater Tank | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savings Project: Insulate Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Addthis Project Level medium Energy Savings $20-$45 annually Time to Complete 1.5 hours Overall Cost $30 Insulate your hot water tank to save energy and money. | Photo courtesy of iStockphoto.com/glennebo Insulate your hot water tank to save energy and money. | Photo courtesy of iStockphoto.com/glennebo Just like insulating your walls or roof, insulating your hot water tank is an easy and inexpensive way to improve energy efficiency and save you money each month. If your water tank is new, it is likely already insulated. If you have an older hot water tank, check to see if it has insulation with an R-value of at least 24. If not, consider insulating your water tank, which

453

Outdoor Outfitter Gets Greener With Solar Water Heater | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater October 8, 2010 - 12:51pm Addthis L.L. Beanñ€™s flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | L.L. Bean's flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | Lindsay Gsell L.L. Bean is known for its outdoor apparel- jackets, backpacks and cozy winter sweaters. However, the company does more than just dress for the outdoors, it also works to protect and preserve it. For nearly 100 years, L.L. Bean has been committed to environmental conservation and

454

SMUD - Solar Water Heater Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heater Rebate Program Solar Water Heater Rebate Program SMUD - Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount 500 - 1,500 per system, depending on energy savings Provider Sacramento Municipal Utility District The Sacramento Municipal Utility District's (SMUD) Solar Domestic Hot Water Program provides rebates and/or loan financing to customers who install solar water heating systems. The amount of the rebate depends on how much electricity the system will offset annually: * 800 - 1,399 kWh: $500 * 1,400 - 2,199 kWh: $1,000 * 2,200 kWh or greater: $1,500 . All solar water-heating units must meet standards set by the Solar Rating

455

Primary heater module (extension), Phase II. Volume I. Final report, January 1984-March 1985  

Science Conference Proceedings (OSTI)

A one year extension to a program of study and research on components and subassemblies of coal fired heaters suitable to supply the heat input to closed-cycle, gas-turbine-based, cogeneration systems of 25 to 50 MWe electrical output was conducted. The research included a 1000 h materials exposure program on a 6 ft x 6 ft atmospheric pressure, fluidized-bed, fired air heater with a 1550 F working fluid exit temperature. The principal purpose of the firings was to evaluate the interrelationships between metal and ceramic materials of heat exchanger construction and the configuration and operating conditions of the fluidized bed air heater. Extensive metallographic and ceramographic analyses were conducted on the metal and ceramics specimens exposed during the firing period. The results indicate that, during operations at 6 fps superficial velocity, the in-bed tubes are coated with a hard deposit of bed material. Erosion is not a problem. But some sulfidation of all metals occurred, presumably due to CaSO/sub 4/ in the deposit. Silicon carbide ceramic specimens showed no degradation. The studies were concerned with: (1) a review of studies previously conducted by Rockwell on both power generation and cogeneration systems, (2) the identification of potential advanced systems, and (3) parametric studies of several advanced systems having the potential for improved economics when compared to the baseline systems. The systems studies and reviews indicated that CCGT ''Power Only'' systems are only marginally competitive with steam turbine based systems. The base-line CCGT cogeneration system at 1450 to 1550 F turbine inlet temperature however is so fuel efficient that it is expected to find commercial application. Several advancements to the base line system were found technically feasible, but judged unlikely to be economically competitive. The radial inflow turbine is suggested as a candidate for development.

Campbell, J.

1985-04-01T23:59:59.000Z

456

Apparatus and method for controlling a heat pump water heater  

Science Conference Proceedings (OSTI)

A method and apparatus for controlling the operation of an add-on heat pump water heater unit is disclosed. A combination of a thermally conductive tube having a flattened portion and a thermostat mounted thereto is utilized to sense the temperature level of water in a tank to which the heater unit is connected. The tube and thermostat are additionally insulated from the ambient. A circulating pump is provided and connected to the water thermostat such that the pump is energized only when it is necessary to operate the heat energy adding unit.

Whitwell, R. J.; Schafer, J. P.

1984-01-08T23:59:59.000Z

457

An Evaluation of the Placement of the Placement of Radiant Barriers on their Effectiveness in Reducing Heat Transfer in Attics  

E-Print Network (OSTI)

Experimental tests were conducted to measure the influence of radiant barriers and the effect of the radiant barrier location on attic heat transfer. All the tests were conducted in an attic simulator at a steady state. The heat flux through the attic floor was measured at two different roof deck temperatures (120°F and 140°F). The temperature distribution within the base fibrous insulation was also measured. Three different solid kraft laminates with aluminum foil backing were tested. There was a 34 percent reduction (sample A) in heat flux through the ceiling for the case where the radiant barrier was placed 6 inches below the roof deck in addition to the base fibrous insulation (R-11), with the roof deck at 140 F. The reduction for the same sample with the radiant barrier placed on the studs of the attic floor was 46 percent. For all the three samples, the heat flux through the attic floor was reduced when the radiant barrier was placed on the attic floor studs.

Katipamula, S.; O'Neal, D.

1986-01-01T23:59:59.000Z

458

Estimating the Cost and Energy Efficiency of a Solar Water Heater...  

NLE Websites -- All DOE Office Websites (Extended Search)

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water...

459

Numerical analysis of thermal-hydrological conditions in the single heater test at Yucca Mountain  

E-Print Network (OSTI)

Single Heater Test at Yucca Mountain, LBNL-39789, E.O. Law­Single Heater Test at Yucca Mountain Jens T. Birkholzer andwaste repository at Yucca Mountain. The heating phase of the

Birkholzer, Jens T.; Tsang, Yvonne W.

1998-01-01T23:59:59.000Z

460

Review of International Methods of Test to Rate the Efficiency of Water Heaters  

E-Print Network (OSTI)

is ?open. ? An open air intake water heater is assigned theof air intake, physical size and load profile of the waterwater heater does not consume a fossil fuel, the air-intake

Lutz, Jim

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

CenterPoint Energy - Residential Gas Heating Rebates | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CenterPoint Energy - Residential Gas Heating Rebates CenterPoint Energy - Residential Gas Heating Rebates CenterPoint Energy - Residential Gas Heating Rebates < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Water Heating Program Info State Arkansas Program Type Utility Rebate Program Rebate Amount Storage Tank Water Heater: $75 Tankless Water Heater: $500 Forced-Air Furnace: $400 - $600 Forced-Air Furnace (Back-Up System): $125 - $175 Hydronic Heating System: $400 Provider CenterPoint Energy CenterPoint Energy offers gas heating and water heating equipment rebates to its residential customers. Eligible equipment includes furnaces, back-up furnace systems, hydronic heaters, storage water heaters and tankless water heaters. All equipment must meet program requirements for efficiency and

462

Study of the effects of ambient conditions upon the performance of fan powered, infrared, natural gas burners. Quarterly report, April 1, 1996 - June 30, 1996  

DOE Green Energy (OSTI)

A porous radiant burner testing facility consisting of a commercial deep-fat fryer, an FTIR based spectral radiance measurement system, a set of flue gas analysis components, and a fuel gas mixing station was constructed. The measurement capabilities of the system were tested using methane and the test results were found to be consistent with the literature. Following the validation of the measurement system, various gas mixtures were tested to study the effect of gas compositions have on burner performance. Results indicated that the emissions vary with fuel gas composition and air/fuel ratio. The maximum radiant efficiency of the burner was obtained close to air/fuel ratio of 1.

Bai, T.; Yeboah, Y.D.; Sampath, R.

1996-07-01T23:59:59.000Z

463

Modeling and Test-and-Rate Methods for Innovative Thermosiphon Solar Water Heaters: Preprint  

SciTech Connect

Conference paper regarding research in modeling and test-and-rate methods for thermosiphon solar domestic water heaters.

Burch, J.; Shoukas, G.; Brandemuhl, M.; Krarti, M.

2006-05-01T23:59:59.000Z

464

Work plan for the Hydrogen Mitigation Test (HMT) rotation motor heater system  

DOE Green Energy (OSTI)

Workplan to design, fabricate, and install a heater system and cover hood for the HMT rotation motor and gearbox.

Vargo, G.F. Jr.

1995-02-16T23:59:59.000Z

465

Diagnosis of Solar Water Heaters Using Solar Storage Tank Surface Temperature Data: Preprint  

DOE Green Energy (OSTI)

Study of solar water heaters by using surface temperature data of solar storage tanks to diagnose proper operations.

Burch, J.; Magnuson, L.; Barker, G.; Bullwinkel, M.

2009-04-01T23:59:59.000Z

466

Questar Gas - Commercial Energy Efficiency Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Questar Gas - Commercial Energy Efficiency Rebate Program Questar Gas - Commercial Energy Efficiency Rebate Program Questar Gas - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Fed. Government Local Government Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Appliances & Electronics Other Water Heating Windows, Doors, & Skylights Maximum Rebate Custom: 50% of the eligible incurred project cost Program Info State Utah Program Type Utility Rebate Program Rebate Amount Custom: $1/therm saved Water Heater: $50-$100 or $2/kBtu/hour input Condensing/Hybrid Water Heater: $350 Clothes Washer: $50-$75 Furnace: $200-$400 Boiler: $2-$3.25/kBtu Tankless Gas Water Heater: $2/kBtu Unit Heater: $1.25-$6/kBtu

467

Texas Gas Service - Commercial Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Texas Gas Service - Commercial Energy Efficiency Rebate Program Texas Gas Service - Commercial Energy Efficiency Rebate Program Texas Gas Service - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Savings Category Appliances & Electronics Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount Front-loading Clothes Washers: up to $100 Commercial Water Heating System: up to 20% of cost Hydronic Heater: $125 per unit Infra-red Fryers: $400 Convection Ovens: $400 Conveyor Ovens: $400 Infra-red Griddles $200 Booster Heater: $500/unit Texas Gas Service (TGS) offers a range of financial incentives to commercal customers who purchase and install energy efficient commercial equipment. Eligible equipment includes commercial clothes washers, water heaters, hydronic heating systems, ovens, fryers, griddles and booster heaters.

468

Texas Gas Service- Residential Solar Water Heating Rebate Program (Texas)  

Energy.gov (U.S. Department of Energy (DOE))

Texas Gas Service offers a flat rebate of $750 for its residential customers within the Austin and Sunset Valley city limits for the installation and purchase of a new solar water heater with...

469

Laclede Gas Company - Commercial and Industrial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Infrared Heaters: 300unit Gas-fired Boiler Tune Up: 75% of cost (non-profit); 50% of cost (C&I Customers) Steam-Trap Replacements: 50% of cost Vent Dampers: 50% of cost...

470

Fault diagnosis of regenerative water heater based-on multi-class support vector machines  

Science Conference Proceedings (OSTI)

The main idea of multi-class support vector machines (SVMs) is described. a multi-class model for regenerative water heater fault diagnosis is presented combining the fuzzy logic and SVMs. The typical faults set of regenerative water heater is built ... Keywords: fault diagnosis, fuzzy rules, regenerative water heater, steam turbine, support vector machines

Lei Wang; Rui-Qing Zhang

2009-08-01T23:59:59.000Z

471

Fault Diagnosis of Regenerative Water Heater Based-On Multi-class Support Vector Machines  

Science Conference Proceedings (OSTI)

The main idea of multi-class support vector machines (SVMs) is described. a multi-class model for regenerative water heater fault diagnosis is presented combining the fuzzy logic and SVMs. The typical faults set of regenerative water heater is built ... Keywords: steam turbine, regenerative water heater, fuzzy rules, support vector machines, fault diagnosis

Lei Wang; Rui-qing Zhang

2009-08-01T23:59:59.000Z

472

Air control can improve field heater efficiency  

SciTech Connect

Independent field tests have demonstrated that the proper selection of primary and secondary air controls for wellhead gas dehydrators can reduce their burner fuel gas consumption by at least 30%. The tests were conducted by G.A. Baca and Associates Ltd., an engineering consulting firm located in Santa Fe, N.M. The new thermostat, venturi burner, and automatic secondary air control combination used in the tests were developed by Weatherford International as part of its Engineered Controls and Instruments (ECI) product line. The principle innovation of Weatherford's ECI burner/control combination is the Automatic Secondary Air Shutter, a device which limits the supply of secondary air surrounding the venturi burner. This air-flow control provides significant improvements in combustion efficiency compared to burners without such controls. Patents for the shutter and burner equipment are pending.

Zygmunt, S.J.; Giovanini, B.

1984-03-26T23:59:59.000Z

473

Design and performance of low-wattage electrical heater probe  

Science Conference Proceedings (OSTI)

A mound electrical calibration heater (MECH) has been used in several EG and G Mound developed calorimeters as a calibration tool. They are very useful over the wattage range of a few to 500 W. At the lower end of the range, a bias develops between the MECH probe and calibrated heat standards. A low-wattage electrical calibration heater (L WECH) probe is being developed by the Safeguards Science and Technology group (NIS-5) of Los Alamos National Laboratory based upon a concept proposed by EG and G Mound personnel. The probe combines electrical resistive heating and laser-light powered heating. The LWECH probe is being developed for use with power settings up to 2W. The electrical heater will be used at the high end of the range, and laser-light power will be used low end of the wattage range. The system consists of two components: the heater probe and a control unit. The probe is inserted into the measuring cavity through an opening in the insulating baffle, and a sleeve is required to adapt to the measuring chamber. The probe is powered and controlled using electronics modules located separately. This paper will report on the design of the LWECH probe, initial tests, and expected performance.

Biddle, R.; Wetzel, J.R. [Los Alamos National Lab., NM (United States); Cech, R. [Global Manufacturing Solutions, Inc., Miamisburg, OH (United States)

1997-11-01T23:59:59.000Z

474

An Analysis of Steam Process Heater Condensate Drainage Options  

E-Print Network (OSTI)

The production and reliability performance of Steam Process Heaters can be significantly affected by the condensate drainage design that is employed. There are currently a variety of drainage options which can be confusing to a system designer who is unaware of the reasons for each specific design. An understanding of the various types and why they may be used follows.

Risko, J. R.

1999-05-01T23:59:59.000Z

475

Marketing and promoting solar water heaters to home builders  

DOE Green Energy (OSTI)

This is the final report of a four-task project to develop a marketing plan designed for businesses interested in marketing solar water heaters in the new home industry. This report outlines suggested marketing communication materials and other promotional tools focused on selling products to the new home builder. Information relevant to promoting products to the new home buyer is also included.

Keller, C.; Ghent, P.

1999-12-06T23:59:59.000Z

476

Life Cycle Management Sourcebooks — Volume 10: Feedwater Heaters  

Science Conference Proceedings (OSTI)

EPRI is producing a series of Life Cycle Management Planning Sourcebooks, each containing a compilation of industry experience and data on aging degradation and historical performance for a specific type of system, structure, or component (SSC). This sourcebook provides information and guidance for implementing cost-effective life cycle management (LCM) planning for feedwater heaters.

2003-12-08T23:59:59.000Z

477

Buildings Energy Data Book: 5.4 Water Heaters  

Buildings Energy Data Book (EERE)

2 Water Heater Stock for Residential Buildings, By Storage Type Small (30 gallons or less) 17.1 17% 1.4 14% 18.5 17% Medium (31 to 49 gallons) 52.4 53% 2.4 24% 54.8 50% Large (50...

478

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect

This report discusses how a significant opportunity for energy savings is domestic hot water heating, where an emerging technology has recently arrived in the U.S. market: the residential integrated heat pump water heater. A laboratory evaluation is presented of the five integrated HPWHs available in the U.S. today.

Sparn, B.; Hudon, K.; Christensen, D.

2011-09-01T23:59:59.000Z

479

Demand Response Performance of GE Hybrid Heat Pump Water Heater  

SciTech Connect

This report describes a project to evaluate and document the DR performance of HPWH as compared to ERWH for two primary types of DR events: peak curtailments and balancing reserves. The experiments were conducted with GE second-generation “Brillion”-enabled GeoSpring hybrid water heaters in the PNNL Lab Homes, with one GE GeoSpring water heater operating in “Standard” electric resistance mode to represent the baseline and one GE GeoSpring water heater operating in “Heat Pump” mode to provide the comparison to heat pump-only demand response. It is expected that “Hybrid” DR performance, which would engage both the heat pump and electric elements, could be interpolated from these two experimental extremes. Signals were sent simultaneously to the two water heaters in the side-by-side PNNL Lab Homes under highly controlled, simulated occupancy conditions. This report presents the results of the evaluation, which documents the demand-response capability of the GE GeoSpring HPWH for peak load reduction and regulation services. The sections describe the experimental protocol and test apparatus used to collect data, present the baselining procedure, discuss the results of the simulated DR events for the HPWH and ERWH, and synthesize key conclusions based on the collected data.

Widder, Sarah H.; Parker, Graham B.; Petersen, Joseph M.; Baechler, Michael C.

2013-07-01T23:59:59.000Z

480

GasSense: appliance-level, single-point sensing of gas activity in the home  

Science Conference Proceedings (OSTI)

This paper presents GasSense, a low-cost, single-point sensing solution for automatically identifying gas use down to its source (e.g., water heater, furnace, fireplace). This work adds a complementary sensing solution to the growing body of work in ... Keywords: gas, sensing, sustainability, ubiquitous computing

Gabe Cohn; Sidhant Gupta; Jon Froehlich; Eric Larson; Shwetak N. Patel

2010-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant gas heaters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Experimental Study on Operating Characteristic of the System of Ground Source Heat Pump Combined with Floor Radiant Heating of Capillary Tube  

Science Conference Proceedings (OSTI)

At first, the article presented particularly the working theory of the system of ground source heat pump combined with floor radiant heating of capillary tube, the characteristic of soil layers and the arrangement form of capillary tube mat and the floor ... Keywords: Ground source heat pump, Capillary tube, Radiant heating, Characteristic, Experiment

Yunzhun Fu; Cai Yingling; Jing Li; Yeyu Wang

2009-10-01T23:59:59.000Z