National Library of Energy BETA

Sample records for radiant floor systems

  1. Impact of Solar Heat Gain on Radiant Floor Cooling System Design

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    Radiant Heating and Cooling Systems, in, 2012. [15] F.Gain on Radiant Floor Cooling System Design. Proceedings ofof radiant floor cooling systems and their associated air

  2. Experimental Study of the Floor Radiant Cooling System Combined with Displacement Ventilation 

    E-Print Network [OSTI]

    Ren, Y.; Li, D.; Zhang, Y.

    2006-01-01

    As a comfortable and energy-efficient air conditioning system, the application of floor radiant heating system is used increasingly greatly in the north of China. As a result, the feasibility of floor radiant cooling has gained more attention...

  3. Design and Experiments of a Solar Low-temperature Hot Water Floor Radiant Heating System 

    E-Print Network [OSTI]

    Wu, Z.; Li, D.

    2006-01-01

    The solar low-temperature hot water floor radiant heating system combines solar energy heating with floor radiant heating. This kind of environmental heating way not only saves fossil resources and reduces pollution, but ...

  4. Impact of Solar Heat Gain on Radiant Floor Cooling System Design

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    Bauman F. 2013. Impact of Solar Heat Gain on Radiant FloorBauman F. 2013. Impact of Solar Heat Gain on Radiant FloorBauman F. 2013. Impact of Solar Heat Gain on Radiant Floor

  5. Modeling thermal comfort with radiant floors and ceilings

    E-Print Network [OSTI]

    2009-01-01

    literatures related to floor heating environment in Japan.of performance of radiant floor-heating systems and a wallB.W. 2002. Radiant floor heating in theory and practice.

  6. Combined Operation of Solar Energy Source Heat Pump, Low-vale Electricity and Floor Radiant System 

    E-Print Network [OSTI]

    Liu, G.; Guo, Z.; Hu, S.

    2006-01-01

    accordin g to heat quantity compared charge according to area. 2.3 Government Encouraging Use of New and Re producible Energy In order to save energy in architecture field, government and MINISRY OF CONSTRUCTIO N P.R. CHINA issue a series of laws... has longer life and its life is up to fifty years. 6) Divided calculation heat is easily carried out i n floor radiant heating system. It is helpful to so lve charge question. According to statistic, it can save energy about 20~30% that charge...

  7. Impact of Solar Heat Gain on Radiant Floor Cooling System Design

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    7] B. Borresen, Floor heating and cooling of an atrium, in:thermal performance of floor heating systems, Solar Energy,discussed this issue for floor heating, but not cooling.

  8. Radiant cooling research scoping study

    E-Print Network [OSTI]

    Moore, Timothy; Bauman, Fred; Huizenga, Charlie

    2006-01-01

    B W. 2002. Radiant Floor Heating in Theory and Practice.the inverse of the radiant floor heating systems that haveresidential radiant floor slab heating systems are often

  9. Cooling load calculations for radiant systems: are they the same traditional methods?

    E-Print Network [OSTI]

    Bauman, Fred; Feng, Jingjuan Dove; Schiavon, Stefano

    2013-01-01

    B. 2008. “Radiant floor cooling systems. ” ASHRAE Journal 4.embedded radiant heating and cooling. Geneva: InternationalM. Deru. 2010. “Radiant slab cooling for retail. ” ASHRAE

  10. Impact of Solar Heat Gain on Radiant Floor Cooling System Design

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    load and capacity; solar heat gain; Radiant design standardssignificance of solar radiation in the design process andthe magnitude of solar impacts under various design/control

  11. Impact of Solar Heat Gain on Radiant Floor Cooling System Design

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    a direct comparison of EnergyPlus simulated radiation heatStandards, 1983. [19] DOE, EnergyPlus Engineering Reference,as the ratio of the EnergyPlus simulated radiant cooling

  12. Numerical Simulation of Thermal Performance of Floor Radiant Heating System with Enclosed Phase Change Material 

    E-Print Network [OSTI]

    Qiu, L.; Wu, X.

    2006-01-01

    of the energy storage floor is designed,which places heat pipes in the enclosed phase change material (PCM) layer, without concrete in it. The PCM thermal storage time is studied in relation to the floor surface temperature under different low-temperature hot...

  13. Green Scheduling for Radiant Systems in Buildings Truong X. Nghiem, Madhur Behl, George J. Pappas and Rahul Mangharam

    E-Print Network [OSTI]

    Pappas, George J.

    reduction for buildings with electric radiant floor heating systems. Uncoordinated operation of a multi-zone radiant floor heating system can result in temporally correlated electricity demand surges or peaks results for general affine dynamical systems and applies them to electric radiant floor heating systems

  14. Design and Control of Hydronic Radiant Cooling Systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove

    2014-01-01

    2000). "The effect of solar radiation on dynamic thermalfloor heating systems." Solar Energy 69(3): 229-237. Awbi,F. Bauman (2013). Impact of Solar Heat Gain on Radiant Floor

  15. Radiant Cooling | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    a steady cooling effect. Homes built on concrete slabs are prime candidates for radiant heating systems, and radiant floor cooling takes advantage of the same principle using...

  16. Energy, cost, and CO2 emission comparison between radiant wall panel1 systems and radiator systems2

    E-Print Network [OSTI]

    Boyer, Edmond

    distribution57 58 1. Introduction59 In Serbia, the concept of the radiant panel heating system (wall and floor the performance of a forced-air and a radiant floor residential heating system connected to71 solar collectors results of operations of 410 space heating systems: the low-temperature radiant panel system without any

  17. Critical review of water based radiant cooling system design methods

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Bauman, Fred; Schiavon, Stefano

    2014-01-01

    shown that radiant system cooling capacity could be enhancedof trends regarding radiant system cooling load analysis andEmbedded Radiant Heating and Cooling Systems, International

  18. Cooling load differences between radiant and air systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    radiant heating and cooling systems, in: Proceedings ofSizing of the radiant system cooling equipment is highlycooling rate and air system cooling rate in this section. To

  19. Radiant vessel auxiliary cooling system

    DOE Patents [OSTI]

    Germer, John H. (San Jose, CA)

    1987-01-01

    In a modular liquid-metal pool breeder reactor, a radiant vessel auxiliary cooling system is disclosed for removing the residual heat resulting from the shutdown of a reactor by a completely passive heat transfer system. A shell surrounds the reactor and containment vessel, separated from the containment vessel by an air passage. Natural circulation of air is provided by air vents at the lower and upper ends of the shell. Longitudinal, radial and inwardly extending fins extend from the shell into the air passage. The fins are heated by radiation from the containment vessel and convect the heat to the circulating air. Residual heat from the primary reactor vessel is transmitted from the reactor vessel through an inert gas plenum to a guard or containment vessel designed to contain any leaking coolant. The containment vessel is conventional and is surrounded by the shell.

  20. Cooling load differences between radiant and air systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    radiant heating and cooling systems, in: Proceedings ofInc, Altanta,GA, 2009. Cooling load differences betweensurface level 24-hour total cooling energy between radiant

  1. Critical review of water based radiant cooling system design methods

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Bauman, Fred; Schiavon, Stefano

    2014-01-01

    buildings CRITICAL REVIEW OF WATER BASED RADIANT COOLINGare two primary types of water-based radiant systems: (1)cooling/heating output, water supply temperatures Notes NA

  2. Experimental comparison of zone cooling load between radiant and air systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Bauman, Fred; Schiavon, Stefano

    2014-01-01

    be used for radiant system cooling load, which should beKeyword Radiant Cooling System, Cooling load, Air system,guidance on radiant system cooling load prediction and

  3. Radiant Heating | Department of Energy

    Office of Environmental Management (EM)

    the cables or tubing in a solid floor and are the oldest form of modern radiant floor systems. The tubing or cable can be embedded in a thick concrete foundation slab (commonly...

  4. Cooling load calculations for radiant systems: are they the same traditional methods?

    E-Print Network [OSTI]

    Bauman, Fred; Feng, Jingjuan Dove; Schiavon, Stefano

    2013-01-01

    of Radiant vs. Air System Cooling Loads Recent simulationsystem, the radiant system cooling Advertisement formerly inthe mea- sured radiant system cooling load. The RTS method

  5. Radiant Heating | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    across the room. When radiant heating is located in the floor, it is often called radiant floor heating or simply floor heating. Radiant heating has a number of advantages. It is...

  6. Thermal Performance Evaluation of Attic Radiant Barrier Systems Using the Large Scale Climate Simulator (LSCS)

    SciTech Connect (OSTI)

    Shrestha, Som S [ORNL] [ORNL; Miller, William A [ORNL] [ORNL; Desjarlais, Andre Omer [ORNL] [ORNL

    2013-01-01

    Application of radiant barriers and low-emittance surface coatings in residential building attics can significantly reduce conditioning loads from heat flow through attic floors. The roofing industry has been developing and using various radiant barrier systems and low-emittance surface coatings to increase energy efficiency in buildings; however, minimal data are available that quantifies the effectiveness of these technologies. This study evaluates performance of various attic radiant barrier systems under simulated summer daytime conditions and nighttime or low solar gain daytime winter conditions using the large scale climate simulator (LSCS). The four attic configurations that were evaluated are 1) no radiant barrier (control), 2) perforated low-e foil laminated oriented strand board (OSB) deck, 3) low-e foil stapled on rafters, and 4) liquid applied low-emittance coating on roof deck and rafters. All test attics used nominal RUS 13 h-ft2- F/Btu (RSI 2.29 m2-K/W) fiberglass batt insulation on attic floor. Results indicate that the three systems with radiant barriers had heat flows through the attic floor during summer daytime condition that were 33%, 50%, and 19% lower than the control, respectively.

  7. Design and Control of Hydronic Radiant Cooling Systems

    E-Print Network [OSTI]

    Feng, Jingjuan

    2014-01-01

    embedded heating and cooling systems. Brussels, Belgium,radiant heating and cooling systems. Proceedings of Climaradiant heating and cooling systems: integration with a

  8. Design and Control of Hydronic Radiant Cooling Systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove

    2014-01-01

    embedded heating and cooling systems. Brussels, Belgium,radiant heating and cooling systems. Proceedings of Climaof Slab Heating and Cooling Systems Studied by Dynamic

  9. Very low temperature radiant heating/cooling indoor end system for efficient use of renewable energies

    SciTech Connect (OSTI)

    Ren, Jianbo; Wang, Yiping; Wang, Congrong; Xiong, Weicheng; Zhu, Li

    2010-06-15

    Solar or solar-assisted space heating systems are becoming more and more popular. The solar energy utilization efficiency is high when the collector is coupled with indoor radiant heating suppliers, since in principle, lower supply temperature means lower demand temperature and then the system heat loss is less. A new type radiant end system is put forward for even lower supply temperature compared to the conventional radiant floor heating systems. A three dimensional model was established to investigate its energy supply capacities. Simulation results show that 50 W per meter length tube can be achieved with the medium temperature of 30 C for heating and 15 C for cooling. The predicted results agree well with the actual data from a demonstration building. Furthermore, it is demonstrated that a supply temperature of 22 C in winter and of 17 C in summer already met the indoor requirements. The new end system has good prospects for effective use of local renewable resources. (author)

  10. Analysis of Attic Radiant Barrier Systems Using Mathematical Models 

    E-Print Network [OSTI]

    Fairey, P.; Swami, M.

    1988-01-01

    During the past six years, the Florida Solar Energy Center (FSEC) has conducted extensive experimental research on radiant barrier systems (RBS). This paper presents recent research on the development of mathematical attic models. Two levels...

  11. Influence of Attic Radiant Barrier Systems on Air Conditioning Demand in an Utility Pilot Project 

    E-Print Network [OSTI]

    Parker, D. S.; Sherwin, J. R.

    2002-01-01

    A utility monitoring project has evaluated radiant barrier systems (RBS) as a new potential demand site management (DSM) program. The study examined how the retrofit of attic radiant barriers can be expected to alter utility residential space...

  12. Co-Designing Sustainable Communities: The Identification and Incorporation of Social Performance Metrics in Native American Sustainable Housing and Renewable Energy System Design

    E-Print Network [OSTI]

    Shelby, Ryan

    2013-01-01

    1) the usage of radiant floor heating to create “warmerPeople Lazy) Tile Floors Bad Heating System (More Control)Heating Radiant Water Heating in Floors and Walls for Use in

  13. Comparison of Zone Cooling Load for Radiant and All-Air Conditioning Systems

    E-Print Network [OSTI]

    Feng, Jingjuan; Schiavon, Stefano; Bauman, Fred

    2012-01-01

    Load for Radiant and Air Conditioning Systems. ProceedingsRefrigerating and Air Conditioning Engineers Inc. Babiak,of European Heating ahd Air-Conditioning Associations. CEN (

  14. Effect of a Radiant Panel Cooling System on Indoor Air Quality of a Conditioned Space 

    E-Print Network [OSTI]

    Mohamed, E.; Abdalla, K. N.

    2010-01-01

    This paper discusses the effect of a radiant cooling panel system on an indoor air quality (IAQ) of a conditioned space. In this study, ceiling radiant cooling panel, mechanical ventilation with fan coil unit (FCU) and 100% fresh air are used...

  15. Comparison of Zone Cooling Load for Radiant and All-Air Conditioning Systems

    E-Print Network [OSTI]

    Feng, Jingjuan; Schiavon, Stefano; Bauman, Fred

    2012-01-01

    Radiant Heating and Cooling Systems. Olesen, B. (2012). "surface heating and cooling systems: . Brussels, EuropeanIn the case of the all-air system, cooling load matches the

  16. Energy, cost, and CO 2 emission comparison between radiant wall panel systems and radiator systems

    E-Print Network [OSTI]

    Milorad Boji?; Dragan Cvetkovi?; Marko Mileti?; Jovan Maleševi?; Harry Boyer

    2012-12-18

    The main goal of this paper is to evaluate the possibility of application or replacement of radiators with low-temperature radiant panels. This paper shows the comparison results of operations of 4 space heating systems: the low-temperature radiant panel system without any additional thermal insulation of external walls (PH-WOI), the low-temperature radiant panel system with additional thermal insulation of external walls (PH-WI), the radiator system without any additional thermal insulation of external walls (the classical heating system) (RH-WOI), and the radiator system with additional thermal insulation of external walls (RH-WI). The operation of each system is simulated by software EnergyPlus. The investigation shows that the PH-WI gives the best results. The RH-WOI has the largest energy consumption, and the largest pollutant emission. However, the PH-WI requires the highest investment.

  17. Performance Evaluation of Radiant Cooling System Integrated with Air System under Different Operational Strategies

    SciTech Connect (OSTI)

    Khare, Vaibhav [Malaviya National Institute of Technology (MNIT), Jaipur, India; Khan, Yasin [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building using a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. The energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.

  18. Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System

    SciTech Connect (OSTI)

    Eigler, N.; Whiting, J.; Chernomorsky, A.; Jackson, J.; Knapp, F.F., Jr.; Litvack, F.

    1998-01-16

    RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified Champion{trademark} over-the-wire, and TNT{trademark} rapid exchange stent delivery balloons. These balloons have thickened polyethylene walls to augment puncture resistance; dual radio-opaque markers and specially configured connectors.

  19. Indoor Humidity Analysis of an Integrated Radiant Cooling and Desiccant Ventilation System 

    E-Print Network [OSTI]

    Gong, X.; Claridge, D. E.

    2006-01-01

    latent heat, they normally are used in conjunction with an independent ventilation system, which is capable of decoupling the space sensible and latent loads. Condensation concerns limit the application of radiant cooling. This paper studies...

  20. Simulation of radiant cooling performance with evaporative cooling sources

    E-Print Network [OSTI]

    Moore, Timothy

    2008-01-01

    B W. 2002. Radiant Floor Heating in Theory and Practice.floors combined eliminates the VAV boxes and permits a reduction in the number of heating

  1. Effects of Radiant Barrier Systems on Ventilated Attics in a Hot and Humid Climate 

    E-Print Network [OSTI]

    Medina, M. A.; O'Neal, D. L.; Turner, W. D.

    1992-01-01

    was not sensitive to increased airflows. The ceiling heat flux reductions produced by the radiant barrier systems were between 25 and 34 percent, with 28 percent being the reduction observed most often in the presence of attic ventilation. All results presented...

  2. Advanced Integrated Systems Technology Development: Personal Comfort Systems and Radiant Slab Systems

    E-Print Network [OSTI]

    2015-01-01

    to the discovery that floor heating had been inadvertentlyDec 15-17 Chair T2-F Floor heating failed Jan 12- 16 Chairpoints for 306 3 rd floor total heating load and temperature

  3. Building Codes and Regulations for Solar Water Heating Systems...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    but the solar thermal system supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography, NREL Active Solar...

  4. Study of the Heating Load of a Manufactured Space with a Gas-fired Radiant Heating System 

    E-Print Network [OSTI]

    Zheng, X.; Dong, Z.

    2006-01-01

    A thermal balance mathematics model of a manufactured space with a gas-fired radiant heating system is established to calculate the heating load. Computer programs are used to solve the model. Envelope internal surface temperatures under different...

  5. Topic 14. Retrofit and optimal operation of the building energy systems Performances of Low Temperature Radiant Heating Systems

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    , wall heating, floor heating, ceiling heating, EnergyPlus SUMMARY Low temperature heating panel systems. It is found that the floor-ceiling heating system has the lowest energy, exergy, CO2 emissions, operating and the surrounding areas, and the heat conduction between the floor and the ground. The main essence of the low

  6. A review of the corrective power of personal comfort systems in non-neutral ambient environments

    E-Print Network [OSTI]

    Zhang, Hui; Arens, Edward; Zhai, Yongchao

    2015-01-01

    heating panel (UD RHP), heating Floor radiant heating panel)heating panel (UD RHP) Floor radiant heating panel (FL RHP)

  7. Technical evaluation of a solar heating system having conventional hydronic solar collectors and a radiant panel slab. Final report

    SciTech Connect (OSTI)

    Starr, R.J.

    1984-04-01

    A simple innovative solar heating design (Solar Option One) using conventional hydronic solar collectors and a radiant panel slab was constructed. An objective of hybrid solar design is to combine the relative advantages of active and passive design approaches while minimizing their respective disadvantages. A test house using the Solar Option One heating system was experimentally monitored to determine its energy based performance during the 1982-83 heating season. The test residence is located in Lyndonville, Vermont, an area which has a characteristically cold and cloudy climate. The two story residence has a floor area of about 1400 square feet and is constructed on a 720 square foot 5.5 inch thick floor slab. A 24 inch packed gravel bed is located beneath the slab and the slab-gravel bed is insulated by two inches of polystyrene insulation. The test building is of frame construction and uses insulation levels which have become commonplace throughout the country. The structure would not fall into the superinsulated category but was tightly constructed so as to have a low infiltration level. The building is sun-tempered in that windows were concentrated somewhat on the South side and all but avoided on the North. A solar greenhouse on the South side of the building was closed off from the structure permanently throughout the testing so as to better observe the solar heating invention without confounding variables. The monitoring equipment generated an internal gain of about 17,000 BTUs per day, roughly the equivalent of occupancy by two persons. A full description of the experimental testing program is given. System efficiency and performance are reported.

  8. Cooling load differences between radiant and air systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    Denmark, 2007. [31] DOE, EnergyPlus Engineering Reference, (2011). [32] DOE, EnergyPlus Energy Simulation Software,system were developed in EnergyPlus v7.1 for comparison. All

  9. Radiant Cooling | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    cooling is appropriate for homes, particularly in the arid Southwest. Radiant cooling systems have been embedded in the ceilings of adobe homes, taking advantage of the thermal...

  10. Simulation of radiant cooling performance with evaporative cooling sources

    E-Print Network [OSTI]

    Moore, Timothy

    2008-01-01

    2000. “Closed Circuit Cooling Tower Selection Program”S R. Lay, 2003 “Radiant Cooling Systems – A Solution forH. 1994. “Hydronic Radiant Cooling Systems. ” Center for

  11. Dynamic Thermal Modeling of a Radiant Panels System and its Environment for Commissioning: Application to Case Study 

    E-Print Network [OSTI]

    Diaz, N. F.; Bertagnolio, S.; Andre, P.

    2009-01-01

    been collected. The simulation of the whole system is performed by means of a dynamic thermal model of the building and its HVAC system. The model considers the radiant panels as a dynamic-state finned heat exchanger connected to a simplified lumped...

  12. Green Scheduling for Radiant Systems in Buildings Truong X. Nghiem, Madhur Behl, George J. Pappas and Rahul Mangharam

    E-Print Network [OSTI]

    Pappas, George J.

    through simulation in EnergyPlus and for a large-scale system through simulation in Matlab. I of production and distribution of electricity. Therefore, peaks in electricity usage are inefficient, Germany, Austria, Denmark [3] and in some parts of the United States [4]. The benefits of radiant systems

  13. Modeling of Residential Attics with Radiant Barriers 

    E-Print Network [OSTI]

    Wilkes, K. E.

    1988-01-01

    This paper gives a summary of the efforts at ORNL in modeling residential attics with radiant barriers. Analytical models based on a system of macroscopic heat balances have been developed. Separate models have been developed for horizontal radiant...

  14. Event-based Green Scheduling of Radiant Systems in Buildings Truong X. Nghiem, George J. Pappas and Rahul Mangharam

    E-Print Network [OSTI]

    Pappas, George J.

    multiple pumps are activated simultaneously. Under a demand-based electricity pricing policy of electric radiant heating systems while maintaining indoor thermal comfort. This paper develops an event as energy storage whose slow thermal behaviour is exploited to provide cooling or heating. Hence

  15. Impact of Solar Heat Gain on Radiant Floor Cooling System Design

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    Menguc, Thermal radiation heat transfer, CRC Press, 2011.convection and radiation heat transfer are compared to theused for this study. Radiation Heat Transfer In the ASHRAE

  16. Impact of Solar Heat Gain on Radiant Floor Cooling System Design

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    M. Filippi, B.W. Olesen, Solar radiation and cooling loadY. Chen, The effect of solar radiation on dynamic thermaldependant upon solar radiation, ASHRAE Transactions, (2006)

  17. Economic Evaluation of Insulation/Radiant Barrier Systems for the State of Texas 

    E-Print Network [OSTI]

    Medina, M. A.; Turner, W. D.; O'Neal, D. L.

    1994-01-01

    on reductions of ceiling heat loads during the summer time, a combination of R-11 with RB was more effective than upgrading the insulation level to R-19. Similarly, adding a radiant barrier to an existing insulation level of R-19 proved more effective than...

  18. Porous radiant burners having increased radiant output

    DOE Patents [OSTI]

    Tong, Timothy W. (Tempe, AZ); Sathe, Sanjeev B. (Tempe, AZ); Peck, Robert E. (Tempe, AZ)

    1990-01-01

    Means and methods for enhancing the output of radiant energy from a porous radiant burner by minimizing the scattering and increasing the adsorption, and thus emission of such energy by the use of randomly dispersed ceramic fibers of sub-micron diameter in the fabrication of ceramic fiber matrix burners and for use therein.

  19. Advanced Integrated Systems Technology Development: Personal Comfort Systems and Radiant Slab Systems

    E-Print Network [OSTI]

    2015-01-01

    Agricultural/Water End-Use Energy Efficiency Renewableof transporting thermal energy with water vs. air (about 7chilled water system, thereby saving energy. When outside

  20. Terminology Radiant Energy (J)

    E-Print Network [OSTI]

    Herrick, Robert R.

    Terminology Radiant Energy (J) Add time Radiant Flux (J/s) add area Hemispherical Directional add, temperature, wavelength, look angle. The temperature of the black body which radiates the same radiant energy as an observed object is called the brightness temperature of the object. Many natural surface materials are well

  1. Heat Pump Systems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    generates hot and cold water rather than air, allowing it to be used with radiant floor heating systems in heating mode. Geothermal (ground-source or water-source) heat...

  2. Preliminary Study of a Vented Attic Radiant Barrier System in Hot, Humid Climates Using Side-by-Side, Full-Scale Test Houses 

    E-Print Network [OSTI]

    Lear, W. E.; Barrup, T. E.; Davis, K. E.

    1987-01-01

    A series of side-by-side tests was performed using two full scale test houses to determine the effectiveness of a Vented Radiant Barrier System (VRBS) in reducing the ceiling heat flux during the summer cooling season in North Florida. Another...

  3. Radiant cooling research scoping study

    E-Print Network [OSTI]

    Moore, Timothy; Bauman, Fred; Huizenga, Charlie

    2006-01-01

    www.Zurn.com PAGE 35 Radiant Cooling Research Scoping Study1988. “Radiant Heating and Cooling, Displacement VentilationHeat Recovery and Storm Water Cooling: An Environmentally

  4. A Classification Scheme for Radiant Systems based on Thermal TimeConstant

    E-Print Network [OSTI]

    Ning, Baisong; Schiavon, Stefano; Bauman, Fred S

    2015-01-01

    Design Manual, Embedded Systems for Commercial Applications.to 7.7 h. Embedded surface systems and thermally activatedbetween 30-91 s; for embedded surface systems between 0.25-

  5. Development of an NC equipment level controller in a hierarchical shop floor control system 

    E-Print Network [OSTI]

    Chang, William

    1993-01-01

    The methodology of developing an NC equipment controller in a Computer Integrated Manufacturing (CIM) System, which is based on a philosophy of hierarchical shop floor control, is presented in this research. The underlying architecture consists...

  6. CFD Simulation and Analysis of the Combined Evaporative Cooling and Radiant Ceiling Air-conditioning System 

    E-Print Network [OSTI]

    Xiang, H.; Yinming, L.; Junmei, W.

    2006-01-01

    Due to such disadvantages as large air duct and high energy consumption of the current all- outdoor air evaporative cooling systems used in the dry region of Northwest China, as well as the superiority of the ceiling cooling system in improving...

  7. Wing Wave: Feasible, Alternative, Renewable, Electrical Energy Producing Ocean Floor System

    E-Print Network [OSTI]

    Wood, Stephen L.

    Wing Wave: Feasible, Alternative, Renewable, Electrical Energy Producing Ocean Floor System Mark, alternative energy system to convert the circular motion of ocean waves as they propagate through the sea and feasible alternative, renewable, electrical energy producing subsea system. Index Terms--ocean energy, wave

  8. Radiant cooling research scoping study

    E-Print Network [OSTI]

    Moore, Timothy; Bauman, Fred; Huizenga, Charlie

    2006-01-01

    recognition of ground-source heat pumps as an option? DesignOmicron A ground source heat pump & radiant heating cooling

  9. Radiant zone heated particulate filter

    DOE Patents [OSTI]

    Gonze, Eugene V [Pinckney, MI

    2011-12-27

    A system includes a particulate matter (PM) filter including an upstream end for receiving exhaust gas and a downstream end. A radiant zoned heater includes N zones, where N is an integer greater than one, wherein each of the N zones includes M sub-zones, where M is an integer greater than or equal to one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones, restricts exhaust gas flow in a portion of the PM filter that corresponds to the selected one of the N zones, and deactivates non-selected ones of the N zones.

  10. Floor System Vibration Control E.M. Hines, Ph.D., P.E., Res. Asst. Professor, Tufts University, Dept. Civ. & Env. Eng.;

    E-Print Network [OSTI]

    Hines, Eric

    Floor System Vibration Control E.M. Hines, Ph.D., P.E., Res. Asst. Professor, Tufts University in the design of steel and concrete floor systems to control vibrations suggests that a floor system's vibration-term collaborative research program between Tufts University and LeMessurier Consultants to investigate the vibration

  11. Radiant energy collector. [Patent application

    DOE Patents [OSTI]

    McIntire, W.R.

    1980-02-14

    A cylindrical radiant energy collector is provided which includes a reflector spaced apart from an energy absorber. The reflector is of a particular shape which ideally eliminates gap losses.

  12. Verification of criticality accident alarm system detector locations for the X-326 process cell floor

    SciTech Connect (OSTI)

    Dobelbower, M.C.; Woollard, J.; Lee, B.L. Jr.; Tayloe, R.W. Jr. [Battelle, Columbus, OH (United States)

    1995-08-01

    Criticality Accident Alarm System (CAAS) detectors on the cell floor of the X-326 process building at the Portsmouth Gaseous Diffusion Plant (PORTS) are located at a height of 5 m above the cell floor. It has been suggested that this height be lowered to I m to alleviate accelerated system failures caused by the elevated temperatures at 5 m and to reduce the frequency of injury to maintenance personnel lifting the approximately 90-lb units into position. Work has been performed which analyzed the effect of relocating the CAAS detectors on the process floors of the X-333 and X-330 buildings from their current height to a height of 1 m{sup 1}. This earlier work was based on criticality accidents occurring in low enriched material (5% {sup 235}U) and was limited to the X-333 and X-330 buildings and the low enriched areas of X-326. It did not consider the residual higher enriched material in the X-326 building. This report analyzes the effect on criticality alarm coverage of lowering the CAAS detectors. This analysis is based on criticality accidents resulting from higher enriched material which may be present as ``hold-up`` in the process equipment within the X-326 building. The criticality accident alarm detectors at the PORTS facility are set to alarm at a neutron absorbed dose rate of 5 mrad/hr. The calculated absorbed dose rates presented in this report show that the detectors examined that produce an alarm for the given criticality event at their current height will also produce an alarm if located at a height of 1 meter. Therefore, lowering the detectors will not result in a loss of coverage within the building.

  13. Performance Testing of Radiant Barriers 

    E-Print Network [OSTI]

    Hall, J. A.

    1986-01-01

    TVA has conducted a study to determine the effects of radiant barriers (RBI (i.e., material with a low emissivity surface facing an air space), when used with fiberglass, on attic heat transfer during summer and winter. This study employed five...

  14. A model for an under floor air distribution system Y.J.P. Lina,*, P.F. Lindenb

    E-Print Network [OSTI]

    Linden, Paul F.

    ; improved thermal comfort; improved ventilation efficiency and indoor air quality; reduced energy useA model for an under floor air distribution system Y.J.P. Lina,*, P.F. Lindenb a Energy gains that occur above the occupied zone are isolated from the calculation of the required space supply

  15. Radiant Heating Basics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    have very low heat capacity and have the quickest response time of any heating technology. More Information Visit the Energy Saver website for more information about radiant...

  16. Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance 

    E-Print Network [OSTI]

    Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

    2004-01-01

    Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time...

  17. Radiant cooling in US office buildings: Towards eliminating the perception of climate-imposed barriers

    SciTech Connect (OSTI)

    Stetiu, C.

    1998-01-01

    Much attention is being given to improving the efficiency of air-conditioning systems through the promotion of more efficient cooling technologies. One such alternative, radiant cooling, is the subject of this thesis. Performance information from Western European buildings equipped with radiant cooling systems indicates that these systems not only reduce the building energy consumption but also provide additional economic and comfort-related benefits. Their potential in other markets such as the US has been largely overlooked due to lack of practical demonstration, and to the absence of simulation tools capable of predicting system performance in different climates. This thesis describes the development of RADCOOL, a simulation tool that models thermal and moisture-related effects in spaces equipped with radiant cooling systems. The thesis then conducts the first in-depth investigation of the climate-related aspects of the performance of radiant cooling systems in office buildings. The results of the investigation show that a building equipped with a radiant cooling system can be operated in any US climate with small risk of condensation. For the office space examined in the thesis, employing a radiant cooling system instead of a traditional all-air system can save on average 30% of the energy consumption and 27% of the peak power demand due to space conditioning. The savings potential is climate-dependent, and is larger in retrofitted buildings than in new construction. This thesis demonstrates the high performance potential of radiant cooling systems across a broad range of US climates. It further discusses the economics governing the US air-conditioning market and identifies the type of policy interventions and other measures that could encourage the adoption of radiant cooling in this market.

  18. Influence of floor plenum on energy performance of buildings with1 UFAD systems2

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    . Thermal29 buoyancy causes temperature stratification in the occupied zone, and the air temperature in the31 to use less energy for cooling [1,2]. In addition, the thermal stratification in a room the occupied zone and the floor plenum also be considered, so do the43 thermal stratification in the occupied

  19. Fact Sheet Radiant barriers and interior radiation control

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    Radiant Barrier Fact Sheet Overview Radiant barriers and interior radiation control coatings 2 in the map below), radiant barriers could reduce your utility bills by as much as $150 per year load. Contents: Overview · What is a radiant barrier? · What is an interior radiation control coating

  20. Electric and Gas Fired Radiant Tubes 'ERT' 

    E-Print Network [OSTI]

    Nilsen, E. K.

    1981-01-01

    The paper covers a unique development by the Surface Division of Midland Ross of a radiant tube heating element which will heat an industrial furnace with either gas or electric without any down time or physical conversion ...

  1. Evaluation of cooling performance of thermally activated building system with evaporative cooling source for typical United States climates

    E-Print Network [OSTI]

    Feng, Jingjuan; Bauman, Fred

    2013-01-01

    embedded surface cooling system and TABS systems THERMALwas simulated. The radiant cooling system was an exposedcooling + radiant cooling system alone may not be able to

  2. Reverberatory screen for a radiant burner

    DOE Patents [OSTI]

    Gray, Paul E. (North East, MD)

    1999-01-01

    The present invention relates to porous mat gas fired radiant burner panels utilizing improved reverberatory screens. The purpose of these screens is to boost the overall radiant output of the burner relative to a burner using no screen and the same fuel-air flow rates. In one embodiment, the reverberatory screen is fabricated from ceramic composite material, which can withstand higher operating temperatures than its metallic equivalent. In another embodiment the reverberatory screen is corrugated. The corrugations add stiffness which helps to resist creep and thermally induced distortions due to temperature or thermal expansion coefficient differences. As an added benefit, it has been unexpectedly discovered that the corrugations further increase the radiant efficiency of the burner. In a preferred embodiment, the reverberatory screen is both corrugated and made from ceramic composite material.

  3. Radiant Barrier Performance during the Heating Season 

    E-Print Network [OSTI]

    Medina, M. A.; O'Neal, D. L.; Turner, W. D.

    1992-01-01

    . Extra null tests limit the number of radiant barrier tests that can be performed during short winter periods. However. nul1tesL~ were run during the months of June 1990 and April 1991 which confirmed that the houses still responded similarly...

  4. An Efficient Instantiation Algorithm for Simulating Radiant Energy Transfer in Plant Models

    E-Print Network [OSTI]

    Boyer, Edmond

    An Efficient Instantiation Algorithm for Simulating Radiant Energy Transfer in Plant Models Cyril CIRAD/INRIA We describe a complete lighting simulation system tailored for the difficult case growth simulation. Other applications of our system range from landscape simulation to agronomical

  5. Radiant cooling research scoping study

    E-Print Network [OSTI]

    Moore, Timothy; Bauman, Fred; Huizenga, Charlie

    2006-01-01

    Air Distribution: Thermal Stratification,” ASHRAE Journal,in the case of thermal stratification of the occupied space.As a result of thermal stratification, all-air UFAD systems

  6. Wing Wave: Feasible, Alternative, Renewable, Electrical Energy Producing Ocean Floor System

    E-Print Network [OSTI]

    Wood, Stephen L.

    and feasible alternative, renewable, electrical energy producing subsea system. Index Terms--ocean energy, wave energy, wave energy converter, WEC, electrical energy, alternative energy, hydrokinetic energy on the coasts of the United States the harvesting ocean wave energy is ideal. It is projected that wave energy

  7. First Floor1 Second Floor2

    E-Print Network [OSTI]

    Gleeson, Joseph G.

    Resource Center Financial Counseling & Infusion Center Scheduling Lactation Room Meditation Garden Infusion Center Clinical Lab Waiting Playground Registration Infusion Center Waiting Second Floor Research Tower . . . . . . . . . . . . . . . . . .Second Conference Room 2250 . . . . . . . . . . . . . . . . . .Second Financial Counseling & Infusion

  8. Impact of the Position of a Radiator to Energy Consumption and Thermal Comfort in a Mixed Radiant and Convective Heating System 

    E-Print Network [OSTI]

    Gong, X.; Claridge, D. E.

    2005-01-01

    Heating energy consumption in winter is an important component of the whole building energy consumption in the severe cold zone in north China. This paper presents a heating water system of a hotel building in Harbin, finishes the testing of its...

  9. Radiant Heating | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProton Delivery andInnovationsRSS FeedCooling Systems

  10. Vented Cavity Radiant Barrier Assembly And Method

    DOE Patents [OSTI]

    Dinwoodie, Thomas L. (Piedmont, CA); Jackaway, Adam D. (Berkeley, CA)

    2000-05-16

    A vented cavity radiant barrier assembly (2) includes a barrier (12), typically a PV module, having inner and outer surfaces (18, 22). A support assembly (14) is secured to the barrier and extends inwardly from the inner surface of the barrier to a building surface (14) creating a vented cavity (24) between the building surface and the barrier inner surface. A low emissivity element (20) is mounted at or between the building surface and the barrier inner surface. At least part of the cavity exit (30) is higher than the cavity entrance (28) to promote cooling air flow through the cavity.

  11. Investigation of errors in the measurement of radiant energy for correlation with primary productivity

    E-Print Network [OSTI]

    Tyler, John E

    1967-01-01

    metric measurement for correlation with primary productivityMEASUREMENT OF RADIANT ENERGY FOR CORRELATION WITH PRIMARY PRODUCTIVITYMEASUREMENT OF RADIANT ENERGY FOR CORRELATION WITH PRIMARY PRODUCTIVITY.

  12. Cooling Energy Measurements of Houses with Attics Containing Radiant Barriers 

    E-Print Network [OSTI]

    Levins, W. P.; Karnitz, M. A.; Knight, D. K.

    1986-01-01

    Tests were conducted by Oak Ridge National Laboratory (ORNL) to determine the magnitude of the energy savings brought about by installing radiant barriers in the attics of single-family houses. The radiant barrier used for this test was a product...

  13. The Influence of Dust on the Absorptivity of Radiant Barriers 

    E-Print Network [OSTI]

    Noboa, Homero L.

    1993-01-01

    The purpose of this project was to model and quantify the increase of the absorptivity of radiant barriers caused by the accumulation of dust on the surface of radiant barriers. This research was the continuation of a previous work by the author...

  14. LEVEL 01 FLOOR LEVEL 1 / GROUND FLOOR / SUPPORT SERVICES BUILDING

    E-Print Network [OSTI]

    Lennard, William N.

    LEVEL 01 FLOOR LEVEL 1 / GROUND FLOOR / SUPPORT SERVICES BUILDING 05/02/2012ACCESSIBILITY WESTERN FLOOR PLAN SUPPORT SERVICES BUILDING Level 2 Lower building Rm.2350 1393 WESTERN ROAD N6G -1G9 UPDATE DRAWN #12;LEVEL 02 FLOOR LEVEL 2 / SECOND FLOOR / SUPPORT SERVICES BUILDING 05/02/2012ACCESSIBILITY

  15. Feasibility of Achieving a Zero-Net-Energy, Zero-Net-Cost Homes

    E-Print Network [OSTI]

    Al-Beaini, S.

    2010-01-01

    A.  (2002).  Radiant?Floor Heating: When It  Does?and A hydronic radiant floor  heating runs hot water through were provided with a floor heating system.  In case of very 

  16. Radiant energy required for infrared neural stimulation

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Tan, Xiaodong; Rajguru, Suhrud; Young, Hunter; Xia, Nan; Stock, Stuart R.; Xiao, Xianghui; Richter, Claus-Peter

    2015-08-25

    Infrared neural stimulation (INS) has been proposed as an alternative method to electrical stimulation because of its spatial selective stimulation. Independent of the mechanism for INS, to translate the method into a device it is important to determine the energy for stimulation required at the target structure. Custom-designed, flat and angle polished fibers, were used to deliver the photons. By rotating the angle polished fibers, the orientation of the radiation beam in the cochlea could be changed. INS-evoked compound action potentials and single unit responses in the central nucleus of the inferior colliculus (ICC) were recorded. X-ray computed tomography wasmore »used to determine the orientation of the optical fiber. Maximum responses were observed when the radiation beam was directed towards the spiral ganglion neurons (SGNs), whereas little responses were seen when the beam was directed towards the basilar membrane. The radiant exposure required at the SGNs to evoke compound action potentials (CAPs) or ICC responses was on average 18.9 ± 12.2 or 10.3 ± 4.9 mJ/cm2, respectively. For cochlear INS it has been debated whether the radiation directly stimulates the SGNs or evokes a photoacoustic effect. The results support the view that a direct interaction between neurons and radiation dominates the response to INS.« less

  17. Design methods for displacement ventilation: Critical review.

    E-Print Network [OSTI]

    Schiavon, Stefano

    2006-01-01

    big space or if cooling/heating floor/ceiling systems areheating system (radiant panels, convectors, radiators or fan coil units at floor

  18. Influence of raised floor on zone design cooling load in commercial buildings.

    E-Print Network [OSTI]

    Schiavon, Stefano; Lee, Kwang Ho; Bauman, Fred; Webster, Tom

    2010-01-01

    Floor and Ceiling Plenum Energy Model Parameters, American Society of Heating,heating and cooling systems were not modelled because the simulation aim was to investigate the influence of the raised floor

  19. Intense Super-radiant X-rays from a Compact Source using a Nanocathode...

    Office of Scientific and Technical Information (OSTI)

    periodically bunched at the wavelength of interest enabling in-phase super-radiant emission that is far more intense than from unbunched electrons. The periodic bunching is...

  20. Low floor mass transit vehicle

    DOE Patents [OSTI]

    Emmons, J. Bruce (Beverly Hills, MI); Blessing, Leonard J. (Rochester, MI)

    2004-02-03

    A mass transit vehicle includes a frame structure that provides an efficient and economical approach to providing a low floor bus. The inventive frame includes a stiff roof panel and a stiff floor panel. A plurality of generally vertical pillars extend between the roof and floor panels. A unique bracket arrangement is disclosed for connecting the pillars to the panels. Side panels are secured to the pillars and carry the shear stresses on the frame. A unique seating assembly that can be advantageously incorporated into the vehicle taking advantage of the load distributing features of the inventive frame is also disclosed.

  1. Radiant energy collection and conversion apparatus and method

    DOE Patents [OSTI]

    Hunt, Arlon J. (Oakland, CA)

    1982-01-01

    The apparatus for collecting radiant energy and converting same to alternate energy form includes a housing having an interior space and a radiation transparent window allowing, for example, solar radiation to be received in the interior space of the housing. Means are provided for passing a stream of fluid past said window and for injecting radiation absorbent particles in said fluid stream. The particles absorb the radiation and because of their very large surface area, quickly release the heat to the surrounding fluid stream. The fluid stream particle mixture is heated until the particles vaporize. The fluid stream is then allowed to expand in, for example, a gas turbine to produce mechanical energy. In an aspect of the present invention properly sized particles need not be vaporized prior to the entrance of the fluid stream into the turbine, as the particles will not damage the turbine blades. In yet another aspect of the invention, conventional fuel injectors are provided to inject fuel into the fluid stream to maintain the proper temperature and pressure of the fluid stream should the source of radiant energy be interrupted. In yet another aspect of the invention, an apparatus is provided which includes means for providing a hot fluid stream having hot particles disbursed therein which can radiate energy, means for providing a cooler fluid stream having cooler particles disbursed therein, which particles can absorb radiant energy and means for passing the hot fluid stream adjacent the cooler fluid stream to warm the cooler fluid and cooler particles by the radiation from the hot fluid and hot particles.

  2. Ocean floor mounting of wave energy converters

    DOE Patents [OSTI]

    Siegel, Stefan G

    2015-01-20

    A system for mounting a set of wave energy converters in the ocean includes a pole attached to a floor of an ocean and a slider mounted on the pole in a manner that permits the slider to move vertically along the pole and rotate about the pole. The wave energy converters can then be mounted on the slider to allow adjustment of the depth and orientation of the wave energy converters.

  3. Advanced Design and Commissioning Tools for Energy-Efficient Building Technologies

    E-Print Network [OSTI]

    Bauman, Fred; Webster, Tom; Zhang, Hui; Arens, Ed

    2012-01-01

    with radiant floor cooling and heating, displacementwith radiant floor cooling and heating, displacementbuilding uses a radiant floor for heating and cooling. This

  4. Spatial variability of throughfall water and chemistry and forest floor water content in a Douglas fir forest stand Hydrology and Earth System Sciences, 6(3), 363374 (2002) EGS

    E-Print Network [OSTI]

    Boyer, Edmond

    2002-01-01

    Spatial variability of throughfall water and chemistry and forest floor water content in a Douglas variability of throughfall water and chemistry and forest floor water content in a Douglas fir forest stand K variability of throughfall water and chemistry and forest floor water content within a Douglas fir

  5. Optical steam quality measurement system and method

    DOE Patents [OSTI]

    Davidson, James R.; Partin, Judy K.

    2006-04-25

    An optical measurement system is presented that offers precision on-line monitoring of the quality of steam. Multiple wavelengths of radiant energy are passed through the steam from an emitter to a detector. By comparing the amount of radiant energy absorbed by the flow of steam for each wavelength, a highly accurate measurement of the steam quality can be determined on a continuous basis in real-time. In an embodiment of the present invention, the emitter, comprises three separate radiant energy sources for transmitting specific wavelengths of radiant energy through the steam. In a further embodiment, the wavelengths of radiant energy are combined into a single beam of radiant energy for transmission through the steam using time or wavelength division multiplexing. In yet a further embodiment, the single beam of radiant energy is transmitted using specialized optical elements.

  6. Radiant energy receiver having improved coolant flow control means

    DOE Patents [OSTI]

    Hinterberger, H.

    1980-10-29

    An improved coolant flow control for use in radiant energy receivers of the type having parallel flow paths is disclosed. A coolant performs as a temperature dependent valve means, increasing flow in the warmer flow paths of the receiver, and impeding flow in the cooler paths of the receiver. The coolant has a negative temperature coefficient of viscosity which is high enough such that only an insignificant flow through the receiver is experienced at the minimum operating temperature of the receiver, and such that a maximum flow is experienced at the maximum operating temperature of the receiver. The valving is accomplished by changes in viscosity of the coolant in response to the coolant being heated and cooled. No remotely operated valves, comparators or the like are needed.

  7. Tankless Coil and Indirect Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    These water heating systems work with forced air systems and hydronic or radiant floor heating systems. Selecting a Combination Water and Space Heating System Integrated...

  8. Policy Strategies and Paths to promote Sustainable Energy Systems - The dynamic Invert Simulation Tool

    E-Print Network [OSTI]

    Stadler, Michael; Kranzl, Lukas; Huber, Claus; Haas, Reinhard; Tsioliaridou, Elena

    2006-01-01

    heating connection of one floor heating system; ss singlecovering one floor respectively central heating; additionalsystems and heating systems covering one floor. • Subsidy

  9. Design and Control of Hydronic Radiant Cooling Systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove

    2014-01-01

    R. Zmeureanu (2009). "Exergy analysis of variable air volume2010). "An exergy application for analysis of buildings and

  10. Cooling load differences between radiant and air systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

    2013-01-01

    can properly model radiation heat transfer are used at thelongwave and shortwave radiation heat transfer and has beenenhanced the radiation heat transfer between the window

  11. Design and Control of Hydronic Radiant Cooling Systems

    E-Print Network [OSTI]

    Feng, Jingjuan Dove

    2014-01-01

    installed to block solar gain, ISO 11855 cooling capacityinstalled to block solar gain, ISO 11855 cooling capacity

  12. Study of the Applications of the Radiant Cooling Panel in Museum Showcases 

    E-Print Network [OSTI]

    Yu, L.; Hou, H.; Wan, X.; Chen, H.

    2006-01-01

    The radiant cooling panel was proposed to control the temperature in the showcases to supply a steadier environment for cultural relic preservation. The new showcase and the convectional one's temperature and flow field were compared by numerical...

  13. Tankless Coil and Indirect Water Heater Basics | Department of...

    Broader source: Energy.gov (indexed) [DOE]

    systems not only can work with forced air systems but also with hydronic or radiant floor heating systems. More Information Visit the Energy Saver website for more...

  14. Relative radiant heat absorption characteristics of two types of mirror shields and a polished aluminum shield 

    E-Print Network [OSTI]

    Herron, Steven Douglas

    1973-01-01

    RELATIVE RADIANT HEAT ABSORPTION CHARACTERISTICS OF TWO TYPES OF MIRROR SHIELDS AND A POLISHED ALUMINUM SHIELD A Thesis by STEVEN DOUGLAS HERRON Submitted to the Graduate College of Texas A&M University in partial fulfillment... of the requirement for the degree of MASTER OF SCIENCE August 1973 Major Subject: Industrial Hygiene RELATIVE RADIANT HEAT ABSORPTION CHARACTERISTICS OF TWO TYPES OF MIRROR SHIELDS AND A POLISHED ALUMINUM SHIELD A Thesis by STEVEN DOUGLAS HERRON Approved...

  15. Impact of Thermally Insulated Floors 

    E-Print Network [OSTI]

    Alghimlas, F.; Omar, E. A.

    2004-01-01

    INSULATED FLOORS E. Al-Sayed Omar Associate Research Scientist Kuwait Institute for Scientific Research P.O. Box 24885, 13109 Safat, Kuwait F. Alghimlas * Research Associate Kuwait Institute for Scientific Research P.O. Box 24885, 13109 Safat..., Kuwait * fghimlas@kisr.edu.kw ABSTRACT Presently in Kuwait the code of practice for energy conservation in the air conditioned buildings implemented by the Ministry of Electricity and Water (MEW) which has been in effect since 1983 has...

  16. Tilting at Modern: Elizabeth Gordon's "The Threat to the Next America"

    E-Print Network [OSTI]

    Corbett, Kathleen LaMoine

    2010-01-01

    solar design and radiant floor heating. 33 The magazine‘sWright had used radiant floor heating earlier, but Keck

  17. Harness the Power of the Sun | Department of Energy

    Office of Environmental Management (EM)

    thermal system (top of roof) supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography. Passive Solar Home...

  18. Principles of Heating and Cooling | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    thermal system (top of roof) supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography. Passive Solar Home...

  19. Using Passive Solar Design to Save Money and Energy | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    thermal system (top of roof) supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography. Passive Solar Home...

  20. Sunrooms and Sunspaces | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    thermal system (top of roof) supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography. Passive Solar Home...

  1. Thermostats | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    learn more about how heating systems and thermostats interact. Limitations for Homes With Heat Pumps, Electric Resistance Heating, Steam Heat, and Radiant Floor Heating...

  2. 2003 Federal Energy and Water Management Award Winners | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    eliminate the need for electrical lighting during the day. A solar-powered radiant floor heating system prevents the water lines in the fire engine bays from freezing....

  3. Effect of Radiant Barrier Technology on Summer Attic Heat Load in South Texas 

    E-Print Network [OSTI]

    Ashley, R.; Garcia, O.; Medina, M. A.; Turner, W. D.

    1994-01-01

    . roof temperatures, and solar radiation were measured. Results of the radiant barrier experiment using two side-by-side 600 ft2 units are presented. Attic fiberglass insulation of nominal R-11 was installed in the two apartments when the units were last...

  4. Coastal ocean optical influences on solar transmission and radiant heating rate

    E-Print Network [OSTI]

    Chang, Grace C.

    on solar transmission, albedo, and heating in nearshore coastal waters. The data were collected from] Understanding of the transmission of solar energy through the upper ocean is essential for quantificationCoastal ocean optical influences on solar transmission and radiant heating rate Grace C. Chang

  5. Brief Communication Effect of asymmetric radiant heating on monodisperse acetone/ethanol

    E-Print Network [OSTI]

    Miller, Richard S.

    Brief Communication Effect of asymmetric radiant heating on monodisperse acetone/ethanol, exploring bi-component droplets of ace- tone/ethanol and acetone/2-propanol mixtures. The ethanol and 2-component droplets composed of acetone/ethanol and acetone/ 2-propanol mixtures (1:1 volume ratio). Fig. 1 shows

  6. Radiant Barrier Insulation Performance in Full Scale Attics with Soffit and Ridge Venting 

    E-Print Network [OSTI]

    Ober, D. G.; Volckhausen, T. W.

    1988-01-01

    There is a limited data base on the full scale performance of radiant barrier insulation in attics. The performance of RBS have been shown to be dependent on attic ventilation characteristics. Tests have been conducted on a duplex located in Florida...

  7. Optimization Online - Efficient Formulations for the Multi-Floor ...

    E-Print Network [OSTI]

    Marc Goetschalckx

    2007-02-28

    Feb 28, 2007 ... ... of the facility layout problem with practical applications when the price ... provided the floor projections on the ground floor are nested starting ...

  8. ETME 422 -REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC -10:00 -10:50am M W F RH 312

    E-Print Network [OSTI]

    Dyer, Bill

    , fans, compressors, heat exchangers, heaters, refrigerators, etc.) of heating, ventilation, air Load - Introduction HVAC Systems Comfort and Health Solar Radiation Radiant Time Series Method Moist

  9. Heat Distribution Systems | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Forced-air systems use ducts that can also be used for central air conditioning and heat pump systems. Radiant heating systems also have unique heat distribution systems. That...

  10. Numerical evaluation of the thermal performances of roof-mounted radiant barriers

    E-Print Network [OSTI]

    Miranville, Frédéric; Lucas, Franck; Johan, Seriacaroupin

    2014-01-01

    This paper deals with the thermal performances of roof-mounted radiant barriers. Using dynamic simulations of a mathematical model of a whole test cell including a radiant barrier installed between the roof top and the ceiling, the thermal performance of the roof is calculated. The mean method is more particularly used to assess the thermal resistance of the building component and lead to a value which is compared to the one obtained for a mass insulation product such as polyurethane foam. On a further stage, the thermal mathematical model is replaced by a thermo-aeraulic model which is used to evaluate the thermal resistance of the roof as a function of the airflow rate. The results shows a better performance of the roof in this new configuration, which is widely used in practice. Finally, the mathematical relation between the thermal resistance and the airflow rate is proposed.

  11. Floor-supply displacement ventilation system

    E-Print Network [OSTI]

    Kobayashi, Nobukazu, 1967-

    2001-01-01

    Research on indoor environments has received more attention recently because reports of symptoms and other health complaints related to indoor environments have been increasing. Heating, ventilating, and air-conditioning ...

  12. PHASE CHANGE MATERIALS IN FLOOR TILES FOR THERMAL ENERGY STORAGE

    SciTech Connect (OSTI)

    Douglas C. Hittle

    2002-10-01

    Passive solar systems integrated into residential structures significantly reduce heating energy consumption. Taking advantage of latent heat storage has further increased energy savings. This is accomplished by the incorporation of phase change materials into building materials used in passive applications. Trombe walls, ceilings and floors can all be enhanced with phase change materials. Increasing the thermal storage of floor tile by the addition of encapsulated paraffin wax is the proposed topic of research. Latent heat storage of a phase change material (PCM) is obtained during a change in phase. Typical materials use the latent heat released when the material changes from a liquid to a solid. Paraffin wax and salt hydrates are examples of such materials. Other PCMs that have been recently investigated undergo a phase transition from one solid form to another. During this process they will release heat. These are known as solid-state phase change materials. All have large latent heats, which makes them ideal for passive solar applications. Easy incorporation into various building materials is must for these materials. This proposal will address the advantages and disadvantages of using these materials in floor tile. Prototype tile will be made from a mixture of quartz, binder and phase change material. The thermal and structural properties of the prototype tiles will be tested fully. It is expected that with the addition of the phase change material the structural properties will be compromised to some extent. The ratio of phase change material in the tile will have to be varied to determine the best mixture to provide significant thermal storage, while maintaining structural properties that meet the industry standards for floor tile.

  13. Tsunami recorded on the open ocean floor

    SciTech Connect (OSTI)

    Filloux, J.H.

    1982-01-01

    On March 14, 1979 a sizeable earth-quake (Ms-7.6 Richter scale) occurred on the continential shelf adjacent to S.W. Mexico, near Petatlan in the state of Guerrero. This earthquake generated a small tsunami that was recorded in deep water, 1000 km away, thus providing for the first time a glance at a tsunami traveling in the open ocean. The same sea floor pressure record displays conspicuous signals associated with vertical sea floor motions generated at the passage of the first Rayleight seismic wave, R1. Seismic and tsunami travel velocities are in agreement with our present understanding of the phenomena, and tsunami detectability in deep water is demonstrated to be well within present day state of the art in the design of sea floor pressure transducers. As calculations anticipate, the E.M. signals associated with the passage of the tsunami were too faint to be detected.

  14. Site Analysis Shadow Analysis Site Objectives

    E-Print Network [OSTI]

    Kyte, Michael

    o Open Loop Geothermal Radiant Floor (Heating and Cooling) o Water Treatment ­ Bioswales o · Provide project/new technology display area Building Systems · Open Loop Geothermal Radiant Floor ­ For heating and cooling Building Systems · Green Roof ­ Insulative purposes ­ Cleans air ­ Replaces lost

  15. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    SciTech Connect (OSTI)

    Backman, C.; German, A.; Dakin, B.; Springer, D.

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  16. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    SciTech Connect (OSTI)

    Backman, C.; German, A.; Dakin, B.; Springer, D.

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  17. Infiltration Investigation of a Radiantly Heated or Cooled Office 

    E-Print Network [OSTI]

    Archer, D. H.; Gong, X.; Claridge, D. E.

    2007-01-01

    dehumidification system. Earlier infiltration measurements using the tracer gas procedure showed infiltration levels of 0.78 - 1.12 ACH, while CO2 concentration measurements gave values from 0.1 - 0.2 ACH. This paper reports the results of infiltration levels...

  18. Advanced Integrated Systems Technology Development: Personal Comfort Systems and Radiant Slab Systems

    E-Print Network [OSTI]

    2015-01-01

    Air Volume Term Definition W Watt ZNE Zero-net-energyConditioning in Near Zero-Net- Energy Buildings The goal ofconstruct a building with zero net energy use. The building

  19. Advanced Integrated Systems Technology Development: Personal Comfort Systems and Radiant Slab Systems

    E-Print Network [OSTI]

    2015-01-01

    1.4-20: Heating water valve position and air and water1.4-22: Heating water valve position and air and water1.4-20: Heating water valve position and air and water

  20. Advanced Integrated Systems Technology Development: Personal Comfort Systems and Radiant Slab Systems

    E-Print Network [OSTI]

    2015-01-01

    exchange, thermal energy storage tanks, heat recovery wheel,exchange, thermal energy storage tanks, heat recovery wheel,

  1. Advanced Integrated Systems Technology Development: Personal Comfort Systems and Radiant Slab Systems

    E-Print Network [OSTI]

    2015-01-01

    CIEE State Partnership for Energy Efficient DemonstrationsAir Volume Term Definition W Watt ZNE Zero-net-energyASHRAE. CPUC. 2011. CA Energy Efficiency Strategic Plan:

  2. Advanced Integrated Systems Technology Development: Personal Comfort Systems and Radiant Slab Systems

    E-Print Network [OSTI]

    2015-01-01

    thermal mass, advanced window blinds that redirect solar energythermal mass, advanced window blinds that redirect solar energy

  3. HRC floors are found in residence centers located

    E-Print Network [OSTI]

    Robeson, Scott M.

    to sign up for housing. No matter the weather, living in an HRC means always having a warm, welcoming home friends on the HRC floors, and end up living with friends from their HRC floor when they move off campus are members of the Hutton Honors Col- lege and many live on HRC floors, but HRC res- idents know how to man

  4. Evaluation of the thermal resistance of a roof-mounted multi-reflective radiant barrier for tropical and humid conditions: Experimental study from field measurements

    E-Print Network [OSTI]

    Miranville, Frédéric; Guichard, Stéphane; Boyer, Harry; Praene, Jean Philippe; Bigot, Dimitri

    2012-01-01

    This paper deals with the experimental evaluation of a roof-mounted multi-reflective radiant barrier (MRRB), installed according to the state of the art, on a dedicated test cell. An existing experimental device was completed with a specific system for the regulation of the airflow rate in the upper air layer included in a typical roof from Reunion Island. Several experimental sequences were conducted to determine the thermal resistance of the roof according to several parameters and following a specific method. The mean method, well known in international standards (ISO 9869 - 1994) for the determination of the thermal resistance using dynamic data, was used. The method was implemented in a building simulation code in order to allow the determination of the thermal indicator automatically. Experimental results are proposed according to different seasonal periods and for different values of the airflow rate in the upper air layer

  5. Evaluation of the thermal resistance of a roof-mounted multi-reflective radiant barrier for tropical and humid conditions: Experimental study from field measurements

    E-Print Network [OSTI]

    Frédéric Miranville; Ali Hamada Fakra; Stéphane Guichard; Harry Boyer; Jean Philippe Praene; Dimitri Bigot

    2012-12-19

    This paper deals with the experimental evaluation of a roof-mounted multi-reflective radiant barrier (MRRB), installed according to the state of the art, on a dedicated test cell. An existing experimental device was completed with a specific system for the regulation of the airflow rate in the upper air layer included in a typical roof from Reunion Island. Several experimental sequences were conducted to determine the thermal resistance of the roof according to several parameters and following a specific method. The mean method, well known in international standards (ISO 9869 - 1994) for the determination of the thermal resistance using dynamic data, was used. The method was implemented in a building simulation code in order to allow the determination of the thermal indicator automatically. Experimental results are proposed according to different seasonal periods and for different values of the airflow rate in the upper air layer.

  6. Building Area Location Grant 3rd Floor Hallway Outside of S304

    E-Print Network [OSTI]

    Ford, James

    Building Area Location Grant 3rd Floor Hallway Outside of S304 Grant 2nd Floor Room S274 Grant 2nd Floor Mailroom A246 (Next to S299) Alway 3rd Floor End of Hallway (By Recycling Bins) Lane Library 1st Beckman Center 3rd Floor Mail / Recycling Area Beckman Center 4th Floor Room B432 Hagey PSRL 1st Floor

  7. Savings Project: Insulate and Air Seal Floors Over Unconditioned...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Project: Insulate and Air Seal Floors Over Unconditioned Garages Tips: Passive Solar Heating and Cooling Where to insulate. Adding insulation in the areas shown here may be...

  8. Strategy Guideline: Quality Management in Existing Homes; Cantilever Floor Example

    SciTech Connect (OSTI)

    Taggart, J.; Sikora, J.; Wiehagen, J.; Wood, A.

    2011-12-01

    This guideline is designed to highlight the QA process that can be applied to any residential building retrofit activity. The cantilevered floor retrofit detailed in this guideline is included only to provide an actual retrofit example to better illustrate the QA activities being presented. The goal of existing home high performing remodeling quality management systems (HPR-QMS) is to establish practices and processes that can be used throughout any remodeling project. The research presented in this document provides a comparison of a selected retrofit activity as typically done versus that same retrofit activity approached from an integrated high performance remodeling and quality management perspective. It highlights some key quality management tools and approaches that can be adopted incrementally by a high performance remodeler for this or any high performance retrofit. This example is intended as a template and establishes a methodology that can be used to develop a portfolio of high performance remodeling strategies.

  9. UCSF EMERGENCY PREPAREDNESS EAP Floor Warden Duties Pamela Roskowski

    E-Print Network [OSTI]

    Derisi, Joseph

    followed Retrieve emergency bag and put on Floor Warden ID vest and hard hat Observe any hazardous or Emergency Responders with status report of condition of assigned floor. Include the last known locations of any injuries, deaths, trapped or missing persons, fires, hazardous materials spills, utility failures

  10. Development of a Transient Heat and Mass Transfer Model of Residential Attics to Predict Energy Savings Produced by the Use of Radiant Barriers 

    E-Print Network [OSTI]

    Medina, M. A.

    1992-01-01

    : different attic insulation levels, various attic airflow rates, cooling and heating seasons, and different radiant barrier orientations. The model predicted ceiling heat flows within 10% for most cases. The model was used to run simulations and parametric...

  11. Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes: Tucson, Arizona and Chico, California (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-11-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  12. OOlldd WWoorrlldd CChhaarrmm wwiitthh MMooddeerrnn CCoonnvveenniieennccee

    E-Print Network [OSTI]

    Johnson, Eric E.

    , and uses very little energy from the PV system. Potable hot water is heated by a Heliodyne GOBI solar hot water collector with a separate PV module for the circulating pump. The boiler used for the radiant), two bathrooms, and a radiant floor heating system ensure 110077www.homepower.com ccooddee corner

  13. Innovative residential floor construction: Structural evaluation of steel joists with pre-formed web openings

    SciTech Connect (OSTI)

    Elhajj, N.R.

    1999-03-01

    Since 1992, the US Department of Housing and Urban Development has sponsored numerous studies to identify, evaluate, and implement innovative structural materials, such as cold-formed steel (CFS), in the residential market. The use of CFS is still very limited, partly because steel is not being effectively integrated into conventional home construction. One of the major barriers to the use of CFS floor joists is the impact it has on placement of large waste drains and ductwork installed in floor systems. This report provides an overview of tests conducted by the NAHB to integrate these systems with CFS. A brief literature review of relevant work followed by a detailed overview of the experimental and analytical approach are also provided. The report recommends adoption of the research findings in residential and commercial applications.

  14. The flow in an under-floor plenum

    E-Print Network [OSTI]

    Choi, Jun Myoung

    2009-01-01

    forced convection dominant flow. REFERENCES Bauman F. , HuiOF CALIFORNIA, SAN DIEGO The Flow in an Under-Floor Plenum A10 3 THE EFFECT OF FLOW RATE AND PLENUM DEPTH…………………15

  15. Full-scale shear tests of embedded floor modules

    SciTech Connect (OSTI)

    Fricke, K.E.; Jones, W.D.; Burdette, E.G.

    1984-01-01

    A floor module used to support a centrifuge machine is a steel framework embedded in a 2-ft (610-mm) thick concrete slab. This steel framework is made up of four cylindrical hollow sockets tied together with four S-beams to form a square pattern. In the event of a centrifuge machine wreck, large forces are transmitted from the machine to the corner sockets (through connecting steel lugs) and to the concrete slab. The floor modules are loaded with a combination of torsion and shear forces in the plane of the floor slab. Precisely how these wreck loads are transmitted to, and reacted by, the floor modules and the surrounding concrete was the scope of a series of full-scale tests performed at the DOE Gas Centrifuge Enrichment Plant (GCEP) located near Piketon, Ohio. This report describes the tests and the results of the data reduction to date.

  16. Comparison of Zone Cooling Load for Radiant and All-Air Conditioning Systems

    E-Print Network [OSTI]

    Feng, Jingjuan; Schiavon, Stefano; Bauman, Fred

    2012-01-01

    conditions, therefore, no heat transmission through buildingto the conductive heat transmission through the building3-5. Table 3 compares the heat transmission through building

  17. Comparison of Zone Cooling Load for Radiant and All-Air Conditioning Systems

    E-Print Network [OSTI]

    Feng, Jingjuan; Schiavon, Stefano; Bauman, Fred

    2012-01-01

    cooling resource, and energy efficiency in transporting heatcooling resource, and energy efficiency in transporting heat

  18. Performance analysis of an integrated UFAD and radiant hydronic slab system

    E-Print Network [OSTI]

    Raftery, Paul; Ho Lee, Kwang; Webster, Tom; Bauman, Fred

    2011-01-01

    validation of the EnergyPlus low-temperature radiantbuilding>. [19] US DOE. EnergyPlus: building technologiesenergy.gov/buildings/energyplus/>. [20] Henninger RH, Witte

  19. Analysis of a hybrid UFAD and radiant hydronic slab HVAC system

    E-Print Network [OSTI]

    Raftery, Paul; Lee, Kwang Ho; Webster, Thomas; Bauman, Fred

    2011-01-01

    Validation of the EnergyPlus Low-Temperature Radiantviewsede/ DOE, “EnergyPlus: Building Technologies Program,”apps1.eere.energy.gov/buildings/energyplus/ DOE, “EnergyPlus

  20. ECOVILLAGE FACTS The complex includes 50 apartments (18 original and 32 new)

    E-Print Network [OSTI]

    Baltisberger, Jay H.

    radiant floor heating o Structurally insulated panels (SIPs) · In additional to individual garden plots

  1. DOE Zero Energy Ready Home Case Study: Ferguson Design and Constructio...

    Energy Savers [EERE]

    double-stud walls, a vaulted roof with R-40 blown cellulose, R-10 XPS under slab, a hydro air system with 91% efficient boiler for forced air and radiant floor heat, and 100%...

  2. DOE Zero Energy Ready Home Case Study: Ferguson Design and Constructio...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    with R-40 blown cellulose, R-10 XPS under slab, a hydro air system with 91% efficient boiler for forced air and radiant floor heat, and 100% LED lights. Ferguson Design &...

  3. Active Solar Heating | Department of Energy

    Energy Savers [EERE]

    Carolina home gets most of its space heating from the passive solar design, but the solar thermal system supplies both domestic hot water and a secondary radiant floor heating...

  4. DOE Zero Energy Ready Home Case Study: Clifton View Homes, Coupeville...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    has a SIP roof and walls, R-20 rigid foam under slab, triple-pane windows, ground source heat pump for radiant floor heat, and a unique balanced ventilation system using separate...

  5. DOE Webinar ? Residential Geothermal Heat Pump Retrofits (Presentatio...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    to the heating fluid or air handler Heat is transferred to the room by radiant floor heating or air distribution system Refrigerant expands causing it to cool Heat Pump...

  6. 2008 Federal Energy and Water Management Award Winners | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    are heated and cooled by a pond-loop geothermal heat pump system, with geothermal radiant floor heating on the main level. The building also incorporates high-efficiency lighting...

  7. An Evaluation of the Placement of the Placement of Radiant Barriers on their Effectiveness in Reducing Heat Transfer in Attics 

    E-Print Network [OSTI]

    Katipamula, S.; O'Neal, D.

    1986-01-01

    the attic floor was measured at two different roof deck temperatures (120°F and 140°F). The temperature distribution within the base fibrous insulation was also measured. Three different solid kraft laminates with aluminum foil backing were tested...

  8. GROUNDLOOPEVAPORATIVEFLUIDCOOLERCHILLERTOGROUNDLOOP CHILLERTOGROUNDLOOP&

    E-Print Network [OSTI]

    California at Davis, University of

    MAKE GALLAGHER HALL LEED PLATINUM RADIANT HEATING AND COOLING 1. Radiant Floor and Ceiling Panels 2H1 C2 C3 C1 C4 HEATING HEATPUMPTO GROUNDLOOP GROUNDLOOPEVAPORATIVEFLUIDCOOLERCHILLERTOGROUNDLOOP HEATING AND COOLING SYSTEM 1211109 8765 4321 GALLAGHER HALL TECHNOLOGIES THE MAIN TECHNOLOGIES THAT HELP

  9. SUESS ET AL.: SEA FLOOR METHANE HYDRATES AT HYDRATE RIDGE, CASCADIA MARGIN Sea Floor Methane Hydrates at Hydrate Ridge, Cascadia Margin

    E-Print Network [OSTI]

    Goldfinger, Chris

    SUESS ET AL.: SEA FLOOR METHANE HYDRATES AT HYDRATE RIDGE, CASCADIA MARGIN 1 Sea Floor Methane are exposed at the sea floor. A methane-oxidizing bacterial consortium populates the exposures of hydrate; colonies of vent macro-fauna are abundant as well. Discharge of methane from destabilized hydrate

  10. Property:Building/FloorAreaShops | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to: navigation,FloorAreaShops Jump

  11. Property:Building/FloorAreaSportCenters | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to: navigation,FloorAreaShops

  12. Property:Building/FloorAreaTotal | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to:FloorAreaTotal Jump to:

  13. Property:Building/FloorAreaWarehouses | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to:FloorAreaTotal

  14. PITTSBURGH AIRPORT MARRIOTT HOTEL FLOOR PLAN

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    10:45 - 12:00 p.m Intermediate Temperature Electrogenerative Cells for Flexible Cogeneration of Power and Liquid Fuel Greg Tao, Materials & Systems Research, Inc. Liquid Fuels...

  15. INSTANTANEOUS FREQUENCY VERSUS TIME FOR 7 BUILDINGS B.0466 Los Angeles, 15250 Ventura Blvd., Roof (13th floor) (pp. 7)

    E-Print Network [OSTI]

    Southern California, University of

    Blvd., Roof (13th floor) (pp. 7) B.5108 Santa Susana, ETEC Bldg 462 (6th Floor, and 1st Floor (pp. 19) B.5450 Burbank, 3601 West Olive Ave., Roof (9th floor) (pp. 11) B.5451 Los Angeles, 6301 Owensmouth Ave., Roof (12th level) (pp. 7) B.5453 Los Angeles, 5805 Sepulveda Blvd., Roof (9th floor) (pp. 13) B

  16. Autonomous Industrial Vehicles: From the Laboratory to the Factory Floor

    E-Print Network [OSTI]

    WORKSHOP Autonomous Industrial Vehicles: From the Laboratory to the Factory Floor 1 IEEE@astm.org 610-832-9720 www.astm.org May 30, 2015 #12;· To solicit researchers and industry input for the development of consensus standards within ASTM International Committee F45 on Driverless Automatic Industrial

  17. Strategy Guideline: Quality Management in Existing Homes - Cantilever Floor Example

    SciTech Connect (OSTI)

    Taggart, J.; Sikora, J.; Wiehagen, J.; Wood, A.

    2011-12-01

    This guideline is designed to highlight the QA process that can be applied to any residential building retrofit activity. The cantilevered floor retrofit detailed in this guideline is included only to provide an actual retrofit example to better illustrate the QA activities being presented.

  18. Modeling, Simulation, and Practice of Floor Control for Synchronous and Ubiquitous

    E-Print Network [OSTI]

    : Floor control, Ubiquitous collaboration, Synchronous collaboration, Mobile devices, Human-computer dispersed virtual place. Mobile computing paradigm [34] made ubiquitous access possible with the integration1 Modeling, Simulation, and Practice of Floor Control for Synchronous and Ubiquitous Collaboration

  19. The Behaviour and Design of Composite Floor Systems in Fire 

    E-Print Network [OSTI]

    Cameron, Neil

    Modern composite steel frame structures possess a high degree of redundancy. This allows them to survive extreme fires without collapse as there are many alternative loadpaths which can be used to transfer load away from the fire affected part...

  20. Production system improvement : floor area reduction and visual management

    E-Print Network [OSTI]

    Chen, Zhuling, M. Eng. Massachusetts Institute of Technology

    2012-01-01

    This thesis suggests on the development process of a new layout design and visual management tools to improve the efficiency of a production line in a medical device company. Lean production philosophy and common lean ...

  1. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    SciTech Connect (OSTI)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

    2005-09-01

    A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Noteworthy achievements six months into the extended life of this cooperative agreement include: (1) Progress on the vertical line array (VLA) of sensors: Analysis and repair attempts of the VLA used in the deep water deployment during October 2003 have been completed; Definition of an interface protocol for the VLA DATS to the SFO has been established; Design modifications to allow integration of the VLA to the SFO have been made; Experience gained in the deployments of the first VLA is being applied to the design of the next VLAs; One of the two planned new VLAs being modified to serve as an Oceanographic Line Array (OLA). (2) Progress on the Sea Floor Probe: The decision to replace the Sea Floor Probe technology with the borehole emplacement of a geophysical array was reversed due to the 1300m water depth at the JIP selected borehole site. The SFP concept has been revisited as a deployment technique for the subsea floor array; The SFP has been redesigned to include gravity driven emplacement of an array up to 10m into the shallow subsurface of the sea floor. (3) Progress on the Acoustic Systems for Monitoring Gas Hydrates: Video recordings of bubbles emitted from a seep in Mississippi Canyon have been analyzed for effects of currents and temperature changes; Several acoustic monitoring system concepts have been evaluated for their appropriateness to MC118, i.e., on the deep sea floor; A mock-up system was built but was rejected as too impractical for deployment on the sea floor. (4) Progress on the Electromagnetic Bubble Detector and Counter: The initial Inductive Conductivity Cell has been constructed from components acquired during the previous reporting period; Laboratory tests involving measuring bubble volume as a component of conductivity have been performed; The laboratory tests were performed in a closed system, under controlled conditions; the relationship between voltage and bubble volume appears to be linear. (5) Progress on the Mid-Infrared Sensor for Continuous Methane Monitoring: Designs and construction schematics for all electronic mounting pieces and an electronics system baseplate were finalized after extensive modeling to facilitate the successful fabrication and implementation of electronic components into the deep-sea, glass instrument housing; Construction schematics and fabrication of an electronics system baseplate have been completed with successful integration of all currently fabricated electronic mounting pieces; Modeling and design of an optics platform complementary to the constructed electronics platform for successful incorporation into ''sphereIR'' has commenced; A second generation chemometric data evaluation software package for evaluating complex spectra including corrections for baseline drifts and spectral anomalies resulting from matrix substances has been developed and will be incorporated into an optimized ''deepSniff'' program upon c

  2. BUILDING CONNECTION ACCESS VIA MAIN ENTRANCE ON PEEL (5TH AND 6TH FLOOR) AND

    E-Print Network [OSTI]

    Shoubridge, Eric

    1ST FLOOR ENTRANCE ELEVATOR WASHROOMS BUILDING CONNECTION ACCESS VIA MAIN ENTRANCE ON PEEL (5TH MCINTYRE MEDICAL SCIENCES BUILDING 3655 SIR WILLIAM OSLER PINE AVENUE PROMENADESIRWILLIAMOSLER ACCESSIBLE BUILDING CONNECTION ACCESS VIA MAIN ENTRANCE ON PEEL (5TH AND 6TH FLOOR) AND SOUTH ENTRANCE (1ST FLOOR) ALL

  3. Predictive pre-cooling control for low lift radiant cooling using building thermal mass

    E-Print Network [OSTI]

    Gayeski, Nicholas (Nicholas Thomas)

    2010-01-01

    Low lift cooling systems (LLCS) hold the potential for significant energy savings relative to conventional cooling systems. An LLCS is a cooling system which leverages existing HVAC technologies to provide low energy cooling ...

  4. Property:Building/FloorAreaHeatedGarages | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)Energy TechnologyFloorAreaHealthServicesDaytime Jump

  5. Property:Building/FloorAreaHotels | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)Energy TechnologyFloorAreaHealthServicesDaytime

  6. Property:Building/FloorAreaRestaurants | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to: navigation, search

  7. Property:Building/TotalFloorArea | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices

  8. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    SciTech Connect (OSTI)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

    2004-03-01

    A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has already succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to innovate research methods and construct necessary instrumentation. As funding for this project, scheduled to commence December 1, 2002, had only been in place for less than half of the reporting period, project progress has been less than for other reporting periods. Nevertheless, significant progress has been made and several cruises are planned for the summer/fall of 2003 to test equipment, techniques and compatibility of systems. En route to reaching the primary goal of the Consortium, the establishment of a monitoring station on the sea floor, the following achievements have been made: (1) Progress on the vertical line array (VLA) of sensors: Software and hardware upgrades to the data logger for the prototype vertical line array, including enhanced programmable gains, increased sampling rates, improved surface communications, Cabling upgrade to allow installation of positioning sensors, Incorporation of capability to map the bottom location of the VLA, Improvements in timing issues for data recording. (2) Sea Floor Probe: The Sea Floor Probe and its delivery system, the Multipurpose sled have been completed; The probe has been modified to penetrate the <1m blanket of hemipelagic ooze at the water/sea floor interface to provide the necessary coupling of the accelerometer with the denser underlying sediments. (3) Electromagnetic bubble detector and counter: Initial tests performed with standard conductivity sensors detected nonconductive objects as small as .6mm, a very encouraging result, Components for the prototype are being assembled, including a dedicated microcomputer to control power, readout and logging of the data, all at an acceptable speed. (4) Acoustic Systems for Monitoring Gas Hydrates: Video recordings of bubbles emitted from a seep in Mississippi Canyon have been made from a submersible dive and the bubbles analyzed with respect to their size, number, and rise rate; these measurements will be used to determine the parameters to build the system capable of measuring gas escaping at the site of the monitoring station; A scattering system and bubble-producing device, being assembled at USM, will be tested in the next two months, and the results compared to a physical scattering model. (5) Mid-Infrared Sensor for Continuous Methane Monitoring: Progress has been made toward minimizing system maintenance through increased capacity and operational longevity, Miniaturization of many components of the sensor systems has been completed, A software package has been designed especially for the MIR sensor data evaluation, Custom electronics have been developed that reduce power consumption and, therefore, increase the length of time the system can remain operational. (6) Seismo-acoustic characterization of sea floor properties and processes at the hydrate monitoring station. (7) Adaptation of the acoustic-logging device, developed as part of the European Union-funded research project, Sub-Gate, for monitoring temporal variations in seabe

  9. Forest floor community metatranscriptomes identify fungal and bacterial responses to N deposition in two maple forests

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Hesse, Cedar N.; Mueller, Rebecca C.; Vuyisich, Momchilo; Gallegos-Graves, La Verne; Gleasner, Cheryl D.; Zak, Donald R.; Kuske, Cheryl R.

    2015-04-23

    Anthropogenic N deposition alters patterns of C and N cycling in temperate forests, where forest floor litter decomposition is a key process mediated by a diverse community of bacteria and fungi. To track forest floor decomposer activity we generated metatranscriptomes that simultaneously surveyed the actively expressed bacterial and eukaryote genes in the forest floor, to compare the impact of N deposition on the decomposers in two natural maple forests in Michigan, USA, where replicate field plots had been amended with N for 16 years. Site and N amendment responses were compared using about 74,000 carbohydrate active enzyme transcript sequences (CAZymes)more »in each metatranscriptome. Parallel ribosomal RNA (rRNA) surveys of bacterial and fungal biomass and taxonomic composition showed no significant differences in either biomass or OTU richness between the two sites or in response to N. Site and N amendment were not significant variables defining bacterial taxonomic composition, but they were significant for fungal community composition, explaining 17 and 14% of the variability, respectively. The relative abundance of expressed bacterial and fungal CAZymes changed significantly with N amendment in one of the forests, and N-response trends were also identified in the second forest. Although the two ambient forests were similar in community biomass, taxonomic structure and active CAZyme profile, the shifts in active CAZyme profiles in response to N-amendment differed between the sites. One site responded with an over-expression of bacterial CAZymes, and the other site responded with an over-expression of both fungal and different bacterial CAZymes. Both sites showed reduced representation of fungal lignocellulose degrading enzymes in N-amendment plots. The metatranscriptome approach provided a holistic assessment of eukaryote and bacterial gene expression and is applicable to other systems where eukaryotes and bacteria interact.« less

  10. Hot Water Distribution System Model Enhancements

    SciTech Connect (OSTI)

    Hoeschele, M.; Weitzel, E.

    2012-11-01

    This project involves enhancement of the HWSIM distribution system model to more accurately model pipe heat transfer. Recent laboratory testing efforts have indicated that the modeling of radiant heat transfer effects is needed to accurately characterize piping heat loss. An analytical methodology for integrating radiant heat transfer was implemented with HWSIM. Laboratory test data collected in another project was then used to validate the model for a variety of uninsulated and insulated pipe cases (copper, PEX, and CPVC). Results appear favorable, with typical deviations from lab results less than 8%.

  11. An intelligent floor field cellular automata model for pedestrian dynamics

    E-Print Network [OSTI]

    Ekaterina Kirik; Tat'yana Yurgel'yan; Dmitriy Krouglov

    2009-06-15

    A stochastic cellular automata (CA) model for pedestrian dynamics is presented. Our goal is to simulate different types of pedestrian movement, from regular to panic. But here we emphasize regular situations which imply that pedestrians analyze environment and choose their route more carefully. And transition probabilities have to depict such effect. The potentials of floor fields and environment analysis are combined in the model obtained. People patience is included in the model. This makes simulation of pedestrians movement more realistic. Some simulation results are presented and comparison with basic FF-model is made.

  12. Property:Building/FloorAreaGroceryShops | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)Energy Technology JumpWilliamDRAFTAreaFloorAreaGroceryShops

  13. Property:Building/FloorAreaOffices | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to: navigation, search This is a

  14. Property:Building/FloorAreaOtherRetail | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to: navigation, search This is

  15. Property:Building/FloorAreaResidential | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to: navigation, search This

  16. Cactus, Pixies, 04 Sept 09 Sittin' here wishin' on a cement floor

    E-Print Network [OSTI]

    Reiners, Peter W.

    Cactus, Pixies, 04 Sept 09 Em Sittin' here wishin' on a cement floor G Em just wishin' that I had that dress when you di-yi-yi-yi-yine Em Sittin' here wishin' on a cement floor G Em just wishin' that I had it to me Em Sittin' here wishin' on a cement floor G Em just wishin' that I had something you wore #12;

  17. 120 years of U.S. residential housing stock and floor space

    SciTech Connect (OSTI)

    Moura, Maria Cecilia P.; Smith, Steven J.; Belzer, David B.; Zhou, Wei -Xing

    2015-08-11

    Residential buildings are a key driver of energy consumption and also impact transportation and land-use. Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO? emissions, with floor space a major driver of building energy demands. In this work a consistent, vintage-disaggregated, annual long-term series of U.S. housing stock and residential floor space for 1891–2010 is presented. An attempt was made to minimize the effects of the incompleteness and inconsistencies present in the national housing survey data. Over the 1891–2010 period, floor space increased almost tenfold, from approximately 24,700 to 235,150 million square feet, corresponding to a doubling of floor space per capita from approximately 400 to 800 square feet. While population increased five times over the period, a 50% decrease in household size contributed towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. GDP and total floor space show a remarkably constant growth trend over the period and total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years, decoupling only within the last decade.

  18. Efficient Formulations for the Multi-Floor Facility Layout Problem with ...

    E-Print Network [OSTI]

    Marc Goetschalckx and Takashi Irohara

    2007-02-22

    Feb 22, 2007 ... problem with practical applications when the price of land is high or when a ... may have different dimensions provided the floor projections on.

  19. Statistical Analysis of Tank 5 Floor Sample Results

    SciTech Connect (OSTI)

    Shine, E. P.

    2013-01-31

    Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, and the radionuclide1, elemental, and chemical concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements above their MDCs. The identification of distributions and the selection of UCL95 procedures generally followed the protocol in Singh, Armbya, and Singh [2010]. When all of an analyte's measurements lie below their MDCs, only a summary of the MDCs can be provided. The measurement results reported by SRNL are listed, and the results of this analysis are reported. The data were generally found to follow a normal distribution, and to be homogenous across composite samples.

  20. Dispersion of UO{sub 2}F{sub 2} aerosol and HF vapor in the operating floor during winter ventilation at the Paducah Gaseous Diffusion Plant

    SciTech Connect (OSTI)

    Kim, S.H.; Chen, N.C.J.; Taleyarkhan, R.P.; Keith, K.D.; Schmidt, R.W. [Oak Ridge National Lab., TN (United States); Carter, J.C. [J.C. Carter Associates, Inc., Knoxville, TN (United States)

    1996-12-30

    The gaseous diffusion process is currently employed at two plants in the US: the Paducah Gaseous Diffusion Plant and the Portsmouth Gaseous Diffusion Plant. As part of a facility-wide safety evaluation, a postulated design basis accident involving large line-rupture induced releases of uranium hexafluoride (UF{sub 6}) into the process building of a gaseous diffusion plant (GDP) is evaluated. When UF{sub 6} is released into the atmosphere, it undergoes an exothermic chemical reaction with moisture (H{sub 2}O) in the air to form vaporized hydrogen fluoride (HF) and aerosolized uranyl fluoride (UO{sub 2}F{sub 2}). These reactants disperse in the process building and transport through the building ventilation system. The ventilation system draws outside air into the process building, distributes it evenly throughout the building, and discharges it to the atmosphere at an elevated temperature. Since air is recirculated from the cell floor area to the operating floor, issues concerning in-building worker safety and evacuation need to be addressed. Therefore, the objective of this study is to evaluate the transport of HF vapor and UO{sub 2}F{sub 2} aerosols throughout the operating floor area following B-line break accident in the cell floor area.

  1. Houses for early weaned piglets : influence of rearing on the floor or in batteries,

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Houses for early weaned piglets : influence of rearing on the floor or in batteries, temperature-deck batteries on wire floor divided into 2 compartments : one at I8.!0 y- i°C, relative humidity 61+ io p. roo and in batteries were the following : 148 and z36 (period I), !2S and 495 (period 11), i. e. differences in favour

  2. UCR Chemistry Program 1953-1966; 2nd floor, Geology Building

    E-Print Network [OSTI]

    Reed, Christopher A.

    UCR Chemistry Program 1953-1970 1953-1966; 2nd floor, Geology Building 1966-2005; Pierce Hall of Physical Sciences ­ chemistry, geology, mathematics, physics ­ W. Conway Pierce, Chairman #12;Hart Schmidt of Geology bld; 1954-66 ­ Plus 2nd floor addition; 1959-66 ­ Pierce Hall; 1966-2005 · Instruments and support

  3. Laboratory testing of a displacement ventilation diffuser for underfloor air distribution systems

    E-Print Network [OSTI]

    Raftery, Paul; Bauman, Fred; Schiavon, Stefano; Epp, Tom

    2015-01-01

    decay in underfloor air distribution (UFAD) systems: for an under floor air distribution system, Energy and of an underfloor air distribution system, Journal of Fluid 

  4. Vitality and chemistry of roots of red spruce in forest floors of stands with a gradient of soil

    E-Print Network [OSTI]

    David, Mark B.

    Vitality and chemistry of roots of red spruce in forest floors of stands with a gradient of soil Al) dominated by red spruce and with a gradient of forest floor exchangeable Al/Ca ratios. Root vitality

  5. Laser multiplexing system

    DOE Patents [OSTI]

    Johnson, Steve A. (Tracy, CA); English, Jr., Ronald Edward (Tracy, CA); White, Ronald K. (Livermore, CA)

    2001-01-01

    A plurality of copper lasers, as radiant power sources, emits a beam of power carrying radiation. A plurality of fiber injection assemblies receives power from the plurality of copper lasers and injects such power into a plurality of fibers for individually transmitting the received power to a plurality of power-receiving devices. The power-transmitting fibers of the system are so arranged that power is delivered therethrough to each of the power-receiving devices such that, even if a few of the radiant power sources and/or fibers fail, the power supply to any of the power receiving devices will not completely drop to zero but will drop by the same proportionate amount.

  6. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    SciTech Connect (OSTI)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

    2005-08-01

    A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to innovate research methods and construct necessary instrumentation. A year into the life of this cooperative agreement, we note the following achievements: (1) Progress on the vertical line array (VLA) of sensors: (A) Software and hardware upgrades to the data logger for the prototype vertical line array, including enhanced programmable gains, increased sampling rates, improved surface communications, (B) Cabling upgrade to allow installation of positioning sensors, (C) Adaptation of SDI's Angulate program to use acoustic slant ranges and DGPS data to compute and map the bottom location of the vertical array, (D) Progress in T''0'' delay and timing issues for improved control in data recording, (E) Successful deployment and recovery of the VLA twice during an October, 2003 cruise, once in 830m water, once in 1305m water, (F) Data collection and recovery from the DATS data logger, (G) Sufficient energy supply and normal functioning of the pressure compensated battery even following recharge after the first deployment, (H) Survival of the acoustic modem following both deployments though it was found to have developed a slow leak through the transducer following the second deployment due, presumably, to deployment in excess of 300m beyond its rating. (2) Progress on the Sea Floor Probe: (A) The Sea Floor Probe and its delivery system, the Multipurpose sled have been completed, (B) The probe has been modified to penetrate the <1m blanket of hemipelagic ooze at the water/sea floor interface to provide the necessary coupling of the accelerometer with the denser underlying sediments, (C) The MPS has been adapted to serve as an energy source for both p- and s-wave studies at the station as well as to deploy the horizontal line arrays and the SFP. (3) Progress on the Electromagnetic Bubble Detector and Counter: (A) Components for the prototype have been assembled, including a dedicated microcomputer to control power, readout and logging of the data, all at an acceptable speed, (B) The prototype has been constructed and preliminary data collected, (C) The construction of the field system is underway. (4) Progress on the Acoustic Systems for Monitoring Gas Hydrates: (A) Video recordings of bubbles emitted from a seep in Mississippi Canyon have been made from a submersible dive and the bubbles analyzed with respect to their size, number, and rise rate. These measurements have been used to determine the parameters to build the system capable of measuring gas escaping at the site of the monitoring station, (B) Laboratory tests performed using the project prototype have produced a conductivity data set that is being used to refine parameters of the field model. (5) Progress on the Mid-Infrared Sensor for Continuous Methane Monitoring: (A) Preliminary designs of mounting pieces for electrical components of ''sphereIR'' have been completed using AutoCAD software, (B) The preliminary design of an electronics baseplate has been completed and aided in the optimization of

  7. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    SciTech Connect (OSTI)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

    2005-11-01

    A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Noteworthy achievements one year into the extended life of this cooperative agreement include: (1) Progress on the vertical line array (VLA) of sensors: (1a) Repair attempts of the VLA cable damaged in the October >1000m water depth deployment failed; a new design has been tested successfully. (1b) The acoustic modem damaged in the October deployment was repaired successfully. (1c) Additional acoustic modems with greater depth rating and the appropriate surface communications units have been purchased. (1d) The VLA computer system is being modified for real time communications to the surface vessel using radio telemetry and fiber optic cable. (1e) Positioning sensors--including compass and tilt sensors--were completed and tested. (1f) One of the VLAs has been redesigned to collect near sea floor geochemical data. (2) Progress on the Sea Floor Probe: (2a) With the Consortium's decision to divorce its activities from those of the Joint Industries Program (JIP), due to the JIP's selection of a site in 1300m of water, the Sea Floor Probe (SFP) system was revived as a means to emplace arrays in the shallow subsurface until arrangements can be made for boreholes at >1000m water depth. (2b) The SFP penetrometer has been designed and construction begun. (2c) The SFP geophysical and pore-fluid probes have been designed. (3) Progress on the Acoustic Systems for Monitoring Gas Hydrates: (3a) Video recordings of bubbles emitted from a seep in Mississippi Canyon have been analyzed for effects of currents and temperature changes. (3b) Several acoustic monitoring system concepts have been evaluated for their appropriateness to MC118, i.e., on the deep sea floor. (3c) A mock-up system was built but was rejected as too impractical for deployment on the sea floor. (4) Progress on the Electromagnetic Bubble Detector and Counter: (4a) Laboratory tests were performed using bubbles of different sizes in waters of different salinities to test the sensitivity of the. Differences were detected satisfactorily. (4b) The system was field tested, first at the dock and then at the shallow water test site at Cape Lookout Bight where methane bubbles from the sea floor, naturally, in 10m water depth. The system successfully detected peaks in bubbling as spike decreases in conductivity. (5) Progress on the Mid-Infrared Sensor for Continuous Methane Monitoring: (5a) Modeling and design of an optics platform complementary to the constructed electronics platform for successful incorporation into ''sphereIR'' continues. AutoCAD design and manual construction of mounting pieces for major optical components have been completed. (5b) Initial design concepts for IR-ATR sensor probe geometries have been established and evaluated. Initial evaluations of a horizontal ATR (HATR) sensing probe with fiber optic guiding light have been performed and validate the design concept as a potentially viable deep sea sensing pr

  8. Technology Solutions Case Study: Interior Foundation Insulation Upgrade-Madison Residence

    SciTech Connect (OSTI)

    2013-10-01

    This basement insulation project included a dimple mat conveying inbound moisture to a draintile, airtight spray polyurethane foam wall and floor insulation, and radiant floor heat installation

  9. 120 years of U.S. residential housing stock and floor space

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Moura, Maria Cecilia P.; Smith, Steven J.; Belzer, David B.; Zhou, Wei -Xing

    2015-08-11

    Residential buildings are a key driver of energy consumption and also impact transportation and land-use. Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO? emissions, with floor space a major driver of building energy demands. In this work a consistent, vintage-disaggregated, annual long-term series of U.S. housing stock and residential floor space for 1891–2010 is presented. An attempt was made to minimize the effects of the incompleteness and inconsistencies present in the national housing survey data. Over the 1891–2010 period, floor space increased almost tenfold, from approximately 24,700 to 235,150 million squaremore »feet, corresponding to a doubling of floor space per capita from approximately 400 to 800 square feet. While population increased five times over the period, a 50% decrease in household size contributed towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. GDP and total floor space show a remarkably constant growth trend over the period and total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years, decoupling only within the last decade.« less

  10. NASA's Earth Observing System CloudsandtheEarth'sRa

    E-Print Network [OSTI]

    of Gary G. Gibson, Head of the Radiation and Aerosols Branch, and Bruce A. Wielicki, CERES for improving our scientific understanding of ongoing natural and human-induced global climate change's Radiant Energy System (CERES) experiment is one of the highest priority sci- entific satellite instruments

  11. Jane Gray Research Greenhouse and IB Sixth Floor Greenhouse Department of Integrative Biology

    E-Print Network [OSTI]

    Jane Gray Research Greenhouse and IB Sixth Floor Greenhouse Department of Integrative Biology UC Berkeley - 200 Centennial Dr. Greenhouse Space Request Form Date of Request____________ Expected time frame_____________________E-mail______________________________________ --------------------------------------------------------------------------------------------------------------------- Greenhouse Environmental Specifications Watering instructions

  12. Modelling heated composite floor slabs with reference to the Cardington experiments 

    E-Print Network [OSTI]

    Gillie, Martin; Usmani, Asif; Rotter, J Michael

    2001-01-01

    This paper describes a method of modelling composite floor slabs in fire conditions using a stress-resultant approach. The FEAST suite, which consists of two main computer programs is described. The first, SRAS, is designed ...

  13. The effectiveness of floor mats as an intervention for standing fatigue of light fabrication workers 

    E-Print Network [OSTI]

    O'Brien, Michael Shannon

    1996-01-01

    A field study was conducted in a light fabrication plant to determine the effectiveness of floor mats on reducing the symptoms of standing fatigue. Specific physiological variables measured include skin temperature of the ...

  14. Ground Floor (Basement) B10 -B10A --IT Service Center

    E-Print Network [OSTI]

    Oklahoma, University of

    -- Living Room 130 -- Buskuhl Gallery B50 ­ Arch 1st Year Studio B60 ­ ID 1st Year Studio B60 East ­ ID 2nd;Second Floor 205 -- Arch 2nd Year Studio (Access by First or Third Floor) 230 -- CNS Classroom 240 -- CNS Year Studio B80 ­ ID 3rd Year Studio B90 ­ ID 4th Year 150, 155, 160 -- Shared Classrooms 165

  15. Remote sensing in marine environment - acquiring, processing, and interpreting GLORIA sidescan sonor images of deep sea floor

    SciTech Connect (OSTI)

    O'Leary, D.W.

    1989-03-01

    The US Geological Survey's remote sensing instrument for regional imaging of the deep sea floor (> 400 m water depth) is the GLORIA (Geologic Long-Range Inclined Asdic) sidescan sonar system, designed and operated by the British Institute of Oceanographic Sciences. A 30-sec sweep rate provides for a swath width of approximately 45 km, depending on water depth. The return signal is digitally recorded as 8 bit data to provide a cross-range pixel dimension of 50 m. Postcruise image processing is carried out by using USGS software. Processing includes precision water-column removal, geometric and radiometric corrections, and contrast enhancement. Mosaicking includes map grid fitting, concatenation, and tone matching. Seismic reflection profiles, acquired along track during the survey, are image correlative and provide a subsurface dimension unique to marine remote sensing. Generally GLORIA image interpretation is based on brightness variations which are largely a function of (1) surface roughness at a scale of approximately 1 m and (2) slope changes of more than about 4/degrees/ over distances of at least 50 m. Broader, low-frequency changes in slope that cannot be detected from the Gloria data can be determined from seismic profiles. Digital files of bathymetry derived from echo-sounder data can be merged with GLORIA image data to create relief models of the sea floor for geomorphic interpretation of regional slope effects.

  16. Inspection of the objects on the sea floor by using 14 MeV tagged neutrons

    SciTech Connect (OSTI)

    Valkovic, V.; Sudac, D.; Obhodas, J.; Matika, D.; Kollar, R.; Nad, K.; Orlic, Z.

    2011-07-01

    Variety of objects found on the sea floor needs to be inspected for the presence of materials which represent the threat to the environment and to the safety of humans. We have demonstrated that the sealed tube 14 MeV neutron generator with the detection of associated alpha particles can be used underwater when mounted inside ROV equipped with the hydraulic legs and variety of sensors for the inspection of such objects for the presence of threat materials. Such a system is performing the measurement by using the NaI gamma detector and an API-120 neutron generator which could be rotated in order to maximize the inspected target volume. The neutron beam intensity during the 10-30 min. measurements is usually 1 x 10{sup 7} n/s in 4{pi}. In this report the experimental results for some of commonly found objects containing TNT explosive or its simulant are presented. The measured gamma spectra are dominant by C, O and Fe peaks enabling the determination of the presence of explosives inside the ammunition shell. Parameters influencing the C/O ratio are discussed in some details. (authors)

  17. Support of Gulf of Mexico Hydrate Research Consortium: Activities to Support Establishment of a Sea Floor Monitoring Station Project

    SciTech Connect (OSTI)

    Carol Lutken

    2006-09-30

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health, was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical, geological, and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. The CMRET has conducted several research cruises during this reporting period: one in April, one in June, one in September. April's effort was dedicated to surveying the mound at MC118 with the Surface-Source-Deep-Receiver (SSDR) seismic surveying system. This survey was completed in June and water column and bottom samples were collected via box coring. A microbial filtering system developed by Consortium participants at the University of Georgia was also deployed, run for {approx}12 hours and retrieved. The September cruise, designed to deploy, test, and in some cases recover, geochemical and microbial instruments and experiments took place aboard Harbor Branch's Seward Johnson and employed the Johnson SeaLink manned submersible. The seafloor monitoring station/observatory is funded approximately equally by three federal Agencies: Minerals Management Services (MMS) of the Department of the Interior (DOI), National Energy Technology Laboratory (NETL) of the Department of Energy (DOE), and the National Institute for Undersea Science and Technology (NIUST), an agency of the National Oceanographic and Atmospheric Administration (NOAA). Subcontractors with FY03 funding fulfilled their technical reporting requirements in a previously submitted report (41628R10). Only unresolved matching funds issues remain and will be addressed in the report of the University of Mississippi's Office of Research and Sponsored Programs. In addition, Barrodale Computing Services Ltd. (BCS) completed their work; their final report is the bulk of the semiannual report that precedes (abstract truncated)

  18. Dark Matter vs. Neutrinos: The effect of astrophysical uncertainties and timing information on the neutrino floor

    E-Print Network [OSTI]

    Jonathan H. Davis

    2015-03-09

    Future multi-tonne Direct Detection experiments will be sensitive to solar neutrino induced nuclear recoils which form an irreducible background to light Dark Matter searches. Indeed for masses around 6 GeV the spectra of neutrinos and Dark Matter are so similar that experiments will run into a neutrino floor, for which sensitivity increases only marginally with exposure past a certain cross section. In this work we show that this floor can be overcome using the different annual modulation expected from solar neutrinos and Dark Matter. Specifically for cross sections below the neutrino floor the DM signal is observable through a phase shift and a smaller amplitude for the time-dependent event rate. This allows the exclusion power to be improved by up to an order of magnitude for large exposures. In addition we demonstrate that the neutrino floor exists over a wider mass range than has been previously shown, since the large uncertainties in the Dark Matter velocity distribution make the signal spectrum harder to distinguish from the neutrino background. However for most velocity distributions the neutrino floor can still be surpassed using timing information, though certain velocity streams may prove problematic.

  19. Advanced Integrated Systems Technology Development

    E-Print Network [OSTI]

    2013-01-01

    NMBE Floor Cooling Floor Heating AHU Fan Energy Conclusions.consumption (for floor cooling and heating models) Tablesimulated energy consumption (for floor cooling and heating

  20. Testing the Floor Scale Designated for Pacific Northwest National Laboratory's UF6 Cylinder Portal Monitor

    SciTech Connect (OSTI)

    Curtis, Michael M.; Weier, Dennis R.

    2009-03-12

    Pacific Northwest National Laboratory (PNNL) obtained a Mettler Toledo floor scale for the purpose of testing it to determine whether it can replace the International Atomic Energy Agency’s (IAEA) cumbersome, hanging load cell. The floor scale is intended for use as a subsystem within PNNL’s nascent UF6 Cylinder Portal Monitor. The particular model was selected for its accuracy, size, and capacity. The intent will be to use it only for 30B cylinders; consequently, testing did not proceed beyond 8,000 lb.

  1. Property:Building/FloorAreaUnheatedRentedPremises | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to:FloorAreaTotal Jump

  2. CATALOG OF PROCESSED DATA FOR 7 BUILDINGS A.0466 Los Angeles, 15250 Ventura Blvd., Roof (13th floor) (pp. 7)

    E-Print Network [OSTI]

    Southern California, University of

    APPENDIX A CATALOG OF PROCESSED DATA FOR 7 BUILDINGS A.0466 Los Angeles, 15250 Ventura Blvd., Roof Burbank, 3601 West Olive Ave., Roof (9th floor) (pp. 11) A.5451 Los Angeles, 6301 Owensmouth Ave., Roof (12th level) (pp. 8) A.5453 Los Angeles, 5805 Sepulveda Blvd., Roof (9th floor) (pp. 19) A.5455 Los

  3. Dark Matter vs. Neutrinos: The effect of astrophysical uncertainties and timing information on the neutrino floor

    E-Print Network [OSTI]

    Davis, Jonathan H

    2015-01-01

    Future multi-tonne Direct Detection experiments will be sensitive to solar neutrino induced nuclear recoils which form an irreducible background to light Dark Matter searches. Indeed for masses around 6 GeV the spectra of neutrinos and Dark Matter are so similar that experiments will run into a neutrino floor, for which sensitivity increases only marginally with exposure past a certain cross section. In this work we show that this floor can be overcome using the different annual modulation expected from solar neutrinos and Dark Matter. Specifically for cross sections below the neutrino floor the DM signal is observable through a phase shift and a smaller amplitude for the time-dependent event rate. This allows the exclusion power to be improved by up to an order of magnitude for large exposures. In addition we demonstrate that the neutrino floor exists over a wider mass range than has been previously shown, since the large uncertainties in the Dark Matter velocity distribution make the signal spectrum harder ...

  4. COOLING OF THE OCEANIC LITHOSPHERE AND OCEAN FLOOR (Copyright, 2001, David T. Sandwell)

    E-Print Network [OSTI]

    Sandwell, David T.

    1 COOLING OF THE OCEANIC LITHOSPHERE AND OCEAN FLOOR TOPOGRAPHY (Copyright, 2001, David T. Sandwell) Introduction This lecture is the development of the lithospheric cooling problem. For researchers in the areas important thermal boundary layer which is at the core-mantle boundary. As the lithosphere cools it becomes

  5. Particle resuspension from indoor flooring materials James H. Lohaus, Atila Novoselac and Jeffrey A. Siegel*

    E-Print Network [OSTI]

    Siegel, Jeffrey

    Particle resuspension from indoor flooring materials James H. Lohaus, Atila Novoselac and Jeffrey A@mail.utexas.edu Keywords: Fluid dynamics, Indoor surfaces, Particle experiments Introduction Particle resuspension from for supermicron particles. Resuspension is usually reported either as a critical velocity, the velocity at which

  6. UNIVERSITY OF NORTH CAROLINA WILMINGTON 1 Office of the Registrar, James Hall--First Floor

    E-Print Network [OSTI]

    Olszewski Jr., Edward A.

    UNIVERSITY OF NORTH CAROLINA WILMINGTON 1 Office of the Registrar, James Hall--First Floor Office/or for the past 12 months. 4. Evidence you are a registered voter in North Carolina. 5. Evidence of motor vehicle ownership - registration card in North Carolina. 6. Copy of North Carolina Driver's License. 7. Evidence

  7. UNIVERSITY OF NORTH CAROLINA WILMINGTON1 Office of the Registrar, James Hall--First Floor

    E-Print Network [OSTI]

    Olszewski Jr., Edward A.

    UNIVERSITY OF NORTH CAROLINA WILMINGTON1 Office of the Registrar, James Hall--First Floor Office (Domiciliary) of North Carolina for Tuition Purposes. 1. Documents of residence for the past 12 months (i are a registered voter in North Carolina. 5. Evidence of motor vehicle ownership - registration card in North

  8. Carbon Dioxide Evolution from the Floor of Three Minnesota Forests Author(s): W. A. Reiners

    E-Print Network [OSTI]

    Thomas, David D.

    Carbon Dioxide Evolution from the Floor of Three Minnesota Forests Author(s): W. A. Reiners and extend access to Ecology. http://www.jstor.org #12;Late Spring 1968 CARBON DIOXIDE EVOLUTION RATES 471. Germination behavior of some halc- phytes. Bull. Res. Council Israel (D) 6: 187-188. CARBON DIOXIDE EVOLUTION

  9. Systemwide Risk Management and Public Safety 401 Golden Shore, 5th Floor

    E-Print Network [OSTI]

    de Lijser, Peter

    Systemwide Risk Management and Public Safety 401 Golden Shore, 5th Floor Long Beach, CA 90802 in this self-insured program. The Office of Risk Management in the Chancellor's Office administers the general liability, workers' compensation, property, and professional liability programs. The State Office of Risk

  10. Beyond Kanban: Creating and analyzing lean shop floor control policies 1

    E-Print Network [OSTI]

    Gershwin, Stanley B.

    Beyond Kanban: Creating and analyzing lean shop floor control policies 1 Asbjoern M. Bonvik ffl Stanley B. Gershwin Operations Research Center, MIT, Cambridge, MA 02139 Laboratory for Manufacturing policies for repetitive manufacturing, including kanban, basestock, and CONWIP control. This view focuses

  11. The Floor Strategy: Wayfinding Cognition in a Multi-Level Building

    E-Print Network [OSTI]

    1 The Floor Strategy: Wayfinding Cognition in a Multi-Level Building Christoph Hölscher1 , Georg and cognitive processes of wayfinding in public buildings. We conducted an empirical study in a complex multi-level building, comparing performance measures of experienced and inexperienced participants in different

  12. 1752 Columbia Rd. NW, Fourth Floor Washington, DC 20009

    E-Print Network [OSTI]

    Kammen, Daniel M.

    money and builders could benefit by increasing their profits according to Power Shift, a non the $8,000-10,000 that installing solar on existing homes costs in part because homebuilders purchase's Buydown and the California Tax Credit the total cost to purchase a two kW system is $5

  13. ECE Graduate Student Affairs Engineering Building I, 2nd Floor

    E-Print Network [OSTI]

    California at San Diego, University of

    -B-C3 Antennas and Their System Applications, Applied Electromagnetic Theory - Electromagnetics and Computational Methods for Electromagnetics ECE 230 A-B-C Solid State Electronics I, II and III ECE 236 A IIIPhotonics, BioElectronics, BioNanotechnology ECE 251 A-B Digital Signal Processing I and II ECE 253 Fundamentals

  14. Building HVAC Requirements Overview Page 4-1 4 Building HVAC Requirements

    E-Print Network [OSTI]

    heating, radiant floor systems, evaporative cooling, gas cooling, ground-source heat pumps, and wood space.1.1 Introduction and Organization This chapter addresses the requirements for heating, ventilating, and air the following topics: 1. Heating Equipment. The first section addresses the requirements for heating equipment

  15. Tender Notice for Renovation of Toilets (Gents & Ladies) on Ground and Second Floor in the Academic Block of ISI Bangalore Centre

    E-Print Network [OSTI]

    Bandyopadhyay, Antar

    Block of ISI Bangalore Centre Sealed tender applications are hereby invited from the contractors (Gents & Ladies) on ground floor and second floor in the Academic block building of ISI, Bangalore Centre

  16. Summary Report: Control Strategies for Mixed-Mode Buildings

    E-Print Network [OSTI]

    Brager, Gail; Borgeson, Sam; Lee, Yoonsu

    2007-01-01

    GSHP; Radiant floor and passive solar heating; decentralizedSlab heating and/or cooling UFAD Forced Air Under Floor Airheating and cooling, conditioned air is delivered through an under floor

  17. Visual Comfort Analysis of Innovative Interior and Exterior Shading Systems for Commercial Buildings using High Resolution Luminance Images

    E-Print Network [OSTI]

    Konis, Kyle

    2011-01-01

    adjustment (e.g. , "winter, "equinox," "summer") to not biasdeg) BA (deg) BA (deg) Height above floor (m) winter equinoxwinter equinox :summer Interior Systems reference-VB split-

  18. Energy and Nutrient Dynamics of Forest Floors in Three Minnesota Forests Author(s): W. A. Reiners and N. M. Reiners

    E-Print Network [OSTI]

    Thomas, David D.

    Energy and Nutrient Dynamics of Forest Floors in Three Minnesota Forests Author(s): W. A. Reiners. http://www.jstor.org #12;497 ENERGY AND NUTRIENT DYNAMICS OF FOREST FLOORS IN THREE MINNESOTA FORESTS and subsequent utilization by heterotrophs is a major pathway of energy flow. Forest floors can also

  19. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    ., V. Ghatti, D.E. Fisher, and D.G. Scheatzle. 2003. "Experimental Validation of the EnergyPlus Low systems. With the recent release of EnergyPlus (Crawley et al. 2000), designers now have the opportunity ASHRAE Vinay Ghatti Student MemberASHRAE The EnergyPlus low-temperature radiant model was experimentally

  20. Three-dimensional modeling of heat transfer from slab floors. Final report

    SciTech Connect (OSTI)

    Bahnfleth, W.P.

    1989-07-01

    Earth-coupled heat-transfer processes have been recognized in recent years as a potential source of significant energy savings in both conventional and earth-sheltered designs, Because of the complexity of the building/soil/atmosphere interaction, however, important aspects of earth-coupled heat transfer are not well understood. There is a particular lack of three-dimensional foundation heat-loss data. In this study, a detailed three-dimensional finite-difference model of a slab floor was used to generate 93 annual simulations in parametric groups focusing on effects of size and shape, soil properties, boundary conditions, climate, insulation, and building shadow. These results indicate that soil thermal conductivity, ground surface conditions, foundation design, and floor shape/size are essential elements of a general change in heat-transfer rate.

  1. Second Floor N314 N313 N312 N311 N310 N309N308

    E-Print Network [OSTI]

    NORTHWEST CORRIDOR N304 N307 N306 Centre for Doctoral Research N305 LIFT First Floor NORTHWEST CORRIDOR N203207 S207A S206S206A S205 S204 S203 S202 MAIN NORTH CORRIDOR M F LINKCORRIDOR LIFT 301 F M D Lift LIFT Lecture Theatre 1 (N111) Seminar Room 1 Tea & Cofee Station Seminar Room 2 Programme Office Office

  2. Property:Building/FloorAreaSchoolsChildDayCare | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to: navigation,

  3. Property:Building/FloorAreaTheatresConcertHallsCinemas | Open Energy

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOffices Jump to:

  4. Underfloor air distribution systems: Benefits and when to use the system in building design

    SciTech Connect (OSTI)

    McCarry, B.T. [Keen Engineering Co., Ltd., Vancouver, British Columbia (Canada)

    1995-12-31

    Underfloor air distribution systems are a viable option for mechanical system building design. They are comprised of raised floor panels with a supply air plenum in the void between the raised floor and the concrete structure. Supply air grilles are flush mounted to the floor to create a flat floor and walking surface. The engineering challenge is to determine when to use underfloor air distribution systems and how to effectively apply them. The best places to use this system are in owner-occupied buildings with a high churn rate and/or frequent technology changes. The benefits of this system include fresh air at the level where building occupants are located, forgiveness for variations in internal cooling loads, easy relocation of the supply air grilles to suit revised layouts, a reduction in energy costs for the mechanical system, and an improvement in indoor air quality.

  5. Wheelchair access to this building is not currently recommended without assistance and is limited to the ground floor.

    E-Print Network [OSTI]

    Edinburgh, University of

    . Lift. Page 10. Stairs. Page 10. Toilets. Page 11. Room Directory. Page 12. Floor Plans, Page 13 at Pollock Halls. The nearest railway line is at Waverley Station in the city centre. The nearest bus stops

  6. Fatigue analysis of stringer to floor beam connections in through plate girder and through truss railroad bridges 

    E-Print Network [OSTI]

    Evans, Leslie Virginia

    1999-01-01

    The objective of this thesis is to determine fatigue stresses in the stringer to floor beam connections of through plate girder (TPG) and through truss (TT) bridges in order to predict failure. Field observations by the Association of American...

  7. Floor Polisher 

    E-Print Network [OSTI]

    Unknown

    2011-08-17

    When steam transfers its heat in a manufacturing process or heat exchanger, it may revert to a liquid phase called condensate. This paper presents a method to help certain manufacturing and petro-chemical companies to save energy costs by returning their...

  8. A framework for on-line simulation systems 

    E-Print Network [OSTI]

    Drake, Glenn Richardson

    1996-01-01

    Simulation has traditionally been used for off-line planning and design. The advent of computer integrated manufacturing and flexible manufacturing systems has increased interest in shop floor control systems that use ...

  9. Open quantum systems and Random Matrix Theory

    E-Print Network [OSTI]

    Declan Mulhall

    2015-01-09

    A simple model for open quantum systems is analyzed with Random Matrix Theory. The system is coupled to the continuum in a minimal way. In this paper we see the effect of opening the system on the level statistics, in particular the $\\Delta_3(L)$ statistic, width distribution and level spacing are examined as a function of the strength of this coupling. A super-radiant transition is observed, and it is seen that as it is formed, the level spacing and $\\Delta_3(L)$ statistic exhibit the signatures of missed levels.

  10. Scheme for generating and transporting THz radiation to the X-ray experimental floor at the LCLS baseline

    E-Print Network [OSTI]

    Geloni, Gianluca; Saldin, Evgeni

    2011-01-01

    This paper describes a novel scheme for integrating a coherent THz source in the baseline of the LCLS facility. Any method relying on the spent electron beam downstream of the baseline undulator should provide a way of transporting the radiation up to the experimental floor. Here we propose to use the dump area access maze. In this way the THz output must propagate with limited size at least for one hundred meters in a maze, following many turns, to reach the near experimental hall. The use of a standard, discrete, open beam-waveguide formed by periodic reflectors, that is a mirror guide, would lead to unacceptable size of the system. To avoid these problems, in this paper we propose an alternative approach based on periodically spaced metallic screens with holes. This quasi-optical transmission line is referred to as an iris line. We present complete calculations for the iris line using both analytical and numerical methods, which we find in good agreement. We present a design of a THz edge radiation source ...

  11. Method and apparatus for recovering a gas from a gas hydrate located on the ocean floor

    DOE Patents [OSTI]

    Wyatt, Douglas E. (Aiken, SC)

    2001-01-01

    A method and apparatus for recovering a gas from a gas hydrate on the ocean floor includes a flexible cover, a plurality of steerable base members secured to the cover, and a steerable mining module. A suitable source for inflating the cover over the gas hydrate deposit is provided. The mining module, positioned on the gas hydrate deposit, is preferably connected to the cover by a control cable. A gas retrieval conduit or hose extends upwardly from the cover to be connected to a support ship on the ocean surface.

  12. Property:Building/FloorAreaHealthServicesDaytime | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)Energy TechnologyFloorAreaHealthServicesDaytime Jump to:

  13. Monitored Performance of an Office Building with an Under-floor Air Distribution System 

    E-Print Network [OSTI]

    Walker, C.; Norford, L.

    2005-01-01

    of the building. The mechanical room is located on the roof above the atrium. The façade is nearly 100% glazing, with fixed shading devices installed to reduce solar heat and glare. On the south and west façades, photovoltaics are integrated into the shading... of the photovoltaics, integrated with the exterior shading devices on the southern and the western façades, to the energy consumption of the building could be determined from the detailed sub- metering data. The monthly contribution of the photovoltaics ranged from...

  14. Innovative accessible sunken floor systems for multi-story steel buildings

    E-Print Network [OSTI]

    Kwan, Henry K

    1987-01-01

    With the demands of telecommunications and computer equipment, building owners and designers are facing an increasingly difficult problem for wire management in today's electronic workplace. This thesis is to investigate ...

  15. BigHorn Home Improvement Center Energy Performance: Preprint

    SciTech Connect (OSTI)

    Deru, M.; Pless, S.; Torcellini, P.

    2006-04-01

    This is one of the nation's first commercial building projects to integrate extensive high-performance design into a retail space. The extensive use of natural light, combined with energy-efficient electrical lighting design, provides good illumination and excellent energy savings. The reduced lighting loads, management of solar gains, and cool climate allow natural ventilation to meet the cooling loads. A hydronic radiant floor system, gas-fired radiant heaters, and a transpired solar collector deliver heat. An 8.9-kW roof-integrated photovoltaic (PV) system offsets a portion of the electricity.

  16. Radiant cooling research scoping study

    E-Print Network [OSTI]

    Moore, Timothy; Bauman, Fred; Huizenga, Charlie

    2006-01-01

    tools to assess energy, thermal, and energy-related economic4.7 AIR FILTRATION AND THERMAL ENERGY RECOVER Shiftingto absorb excess thermal energy and remove it from a space.

  17. ORNL Radiant Barrier - ETSD Division

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ETSD Division EES Directorate ORNL Building Technologies Research and Integration Center Energy and Transportation Science Division Overview How do radiation barriers save energy?...

  18. Radiant Barriers | Department of Energy

    Office of Environmental Management (EM)

    points to make at least a 1.0 inch (2.5 cm) air space between it and the bottom of the roof. Foil-faced plywood or oriented strand board sheathing is also available. Note that...

  19. Radiant Barriers | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    way a spoon placed in a hot cup of coffee conducts heat through its handle to your hand. Heat transfer by convection occurs when a liquid or gas -- air, for example -- is heated,...

  20. Radiant cooling research scoping study

    E-Print Network [OSTI]

    Moore, Timothy; Bauman, Fred; Huizenga, Charlie

    2006-01-01

    sources, such as solar-thermal collectors, or the optimizedfrom roof-mounted solar thermal collectors. A phase-change

  1. Radiant Solar | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onRAPID/Geothermal/Exploration/Colorado <RAPID/Geothermal/Water Use/NevadaaTools <REpowerFormRSIRYPOSRadiance:Solar

  2. Radiant Apparatus | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to:EA EIS Report UrlNM-b < RAPID‎ |RENERCO RenewableRGSRadar

  3. Radiant Energy | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to:EA EIS Report UrlNM-b < RAPID‎ |RENERCO RenewableRGSRadarEnergy Jump

  4. Radiant Barriers | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann JacksonDepartment of EnergyResearchers at the Energy Department's National

  5. Radiant Barriers | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative FuelsofProgram: Report Appendices |ProjectKnow Your PowerWeatherize » Insulation »

  6. Radiant Cooling | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative FuelsofProgram: Report Appendices |ProjectKnow Your PowerWeatherize » Insulation

  7. Radiant Heating | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative FuelsofProgram: Report Appendices |ProjectKnow Your PowerWeatherize » InsulationHeat

  8. Pupillary efficient lighting system

    DOE Patents [OSTI]

    Berman, Samuel M. (San Francisco, CA); Jewett, Don L. (Mill Valley, CA)

    1991-01-01

    A lighting system having at least two independent lighting subsystems each with a different ratio of scotopic illumination to photopic illumination. The radiant energy in the visible region of the spectrum of the lighting subsystems can be adjusted relative to each other so that the total scotopic illumination of the combined system and the total photopic illumination of the combined system can be varied independently. The dilation or contraction of the pupil of an eye is controlled by the level of scotopic illumination and because the scotopic and photopic illumination can be separately controlled, the system allows the pupil size to be varied independently of the level of photopic illumination. Hence, the vision process can be improved for a given level of photopic illumination.

  9. 2009 Federal Energy and Water Management Award Winners | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and energy-saving features include active and passive heating and cooling, radiant floor heating, energy recovery and natural ventilation; high performance glazing; daylight...

  10. Thermostats | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for Homes With Heat Pumps, Electric Resistance Heating, Steam Heat, and Radiant Floor Heating Programmable thermostats are generally not recommended for heat pumps. In...

  11. Adjudication of a Contract for the Supply of False Floors for the Auxiliary Buildings of the 300 GeV Accelerator

    E-Print Network [OSTI]

    1973-01-01

    Adjudication of a Contract for the Supply of False Floors for the Auxiliary Buildings of the 300 GeV Accelerator

  12. DIY World Builder: An Immersive Level-Editing System Owen Leach**

    E-Print Network [OSTI]

    Lindeman, Robert W.

    , with motion-capture cameras, fans, and the passive floor surface, (b) terrain editing with the wand, (c control on the tablet. ABSTRACT This paper presents an immersive system for building virtual worlds from through a vibrotactile belt and a novel passive floor technique are used to indicate to the user when she

  13. Development of a Leave-in-Place Slab Edge Insulating Form System

    SciTech Connect (OSTI)

    Marc Hoeschele; Eric Lee

    2009-08-31

    Concrete slabs represent the primary foundation type in residential buildings in the fast-growing markets throughout the southern and southwestern United States. Nearly 75% of the 2005 U.S. population growth occurred in these southern tier states. Virtually all of these homes have uninsulated slab perimeters that transfer a small, but steady, flow of heat from conditioned space to outdoors during the heating season. It is estimated that new home foundations constructed each year add 0.016 quads annually to U.S. national energy consumption; we project that roughly one quarter of this amount can be attributed to heat loss through the slab edge and the remaining three quarters to deep ground transfers, depending upon climate. With rising concern over national energy use and the impact of greenhouse gas emissions, it is becoming increasingly imperative that all cost-effective efforts to improve building energy efficiency be implemented. Unlike other building envelope components that have experienced efficiency improvements over the years, slab edge heat loss has largely been overlooked. From our vantage point, a marketable slab edge insulation system would offer significant benefits to homeowners, builders, and the society as a whole. Conventional slab forming involves the process of digging foundation trenches and setting forms prior to the concrete pour. Conventional wood form boards (usually 2 x 10's) are supported by vertical stakes on the outer form board surface, and by supporting 'kickers' driven diagonally from the top of the form board into soil outside the trench. Typically, 2 x 10's can be used only twice before they become waste material, contributing to an additional 400 pounds of construction waste per house. Removal of the form boards and stakes also requires a follow-up trip to the jobsite by the concrete subcontractor and handling (storage/disposal) of the used boards. In the rare cases where the slab is insulated (typically custom homes with radiant floor heating), the most practical insulation strategy is to secure rigid foam insulation, such as Dow Styrofoam{trademark}, to the inside of the wooden slab edge forms. An alternative is to clad insulation to the perimeter of the slab after the slab has been poured and cured. In either case, the foam must have a 'termite strip' that prevents termites from creating hidden tunnels through or behind the foam on their way to the wall framing above. Frequently this termite strip is a piece of sheet metal that must be fabricated for each project. The above-grade portion of the insulation also needs to be coated for appearance and to prevent damage from construction and UV degradation. All these steps add time, complexity, and expense to the insulating process.

  14. Ground Water Cooling System 

    E-Print Network [OSTI]

    Greaves, K.; Chave, G. H.

    1984-01-01

    has a total shop area of 128,000 square feet and the majority of the machine tools are equipped with computerized numerical controls. The cooling system was designed around five (5) floor mounted, 50,000 CFM, air handling units which had been...

  15. Optical Spectrum Analyzer with Quantum-Limited Noise Floor M. Bishof, X. Zhang, M. J. Martin, and Jun Ye

    E-Print Network [OSTI]

    Optical Spectrum Analyzer with Quantum-Limited Noise Floor M. Bishof, X. Zhang, M. J. Martin with state-of-the-art stability. We demonstrate a technique that precisely measures the noise spectrum determine the laser noise spectrum from near dc to 100 Hz via the measured fluctuations in atomic excitation

  16. PII S0016-7037(00)00511-1 Reaction of forest floor organic matter at goethite, birnessite and smectite surfaces

    E-Print Network [OSTI]

    Chorover, Jon

    PII S0016-7037(00)00511-1 Reaction of forest floor organic matter at goethite, birnessite carbon (DOC) concentrations (0­140 g C m 3 ) for reaction with goethite ( -FeOOH), birnessite ( -MnO2 different NOM adsorption, fractionation and transformation patterns. Goethite exhibited a steep initial

  17. Job Opportunity at NEUROMATTERS, LLC 40 Wall Street, 28th Floor, New York, NY 10005 www.neuromatters.com

    E-Print Network [OSTI]

    Adams, Mark

    , Neuromatters is at the forefront of neurotechnologies, EEG signal processing and decoding. The successfulJob Opportunity at NEUROMATTERS, LLC 40 Wall Street, 28th Floor, New York, NY 10005 www.neuromatters.com Founded by recognized neuroengineering experts from Columbia University and the City College of New York

  18. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    SciTech Connect (OSTI)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis; Bob A. Hardage; Jeffrey Chanton; Rudy Rogers

    2006-03-01

    The Gulf of Mexico Hydrates Research Consortium was established in 1999 to assemble leaders in gas hydrates research. The group is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station has always included the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. This possibility has recently received increased attention and the group of researchers working on the station has expanded to include several microbial biologists. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments are planned for fall 2005 and center about the use of the vessel M/V Ocean Quest and its two manned submersibles. The subs will be used to effect bottom surveys, emplace sensors and sea floor experiments and make connections between sensor data loggers and the integrated data power unit (IDP). Station/observatory completion is anticipated for 2007 following the construction, testing and deployment of the horizontal line arrays, not yet funded. The seafloor monitoring station/observatory is funded approximately equally by three federal Agencies: Minerals Management Services (MMS) of the Department of the Interior (DOI), National Energy Technology Laboratory (NETL) of the Department of Energy (DOE), and the National Institute for Undersea Science and Technology (NIUST), an agency of the National Oceanographic and Atmospheric Administration (NOAA).

  19. Support of Gulf of Mexico Hydrate Research Consortium: Activities to Support Establishment of a Sea Floor Monitoring Station Project

    SciTech Connect (OSTI)

    J. Robert Woolsey; Thomas M. McGee; Carol Blanton Lutken; Elizabeth Stidham

    2007-03-31

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health, was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical, geological, and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 (MC118) in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. These delays caused scheduling and deployments difficulties but many sensors and instruments were completed during this period. Software has been written that will accommodate the data that the station retrieves, when it begins to be delivered. In addition, new seismic data processing software has been written to treat the peculiar data to be received by the vertical line array (VLA) and additional software has been developed that will address the horizontal line array (HLA) data. These packages have been tested on data from the test deployments of the VLA and on data from other, similar, areas of the Gulf (in the case of the HLA software). The CMRET has conducted one very significant research cruise during this reporting period: a March cruise to perform sea trials of the Station Service Device (SSD), the custom Remotely Operated Vehicle (ROV) built to perform several of the unique functions required for the observatory to become fully operational. March's efforts included test deployments of the SSD and Florida Southern University's mass spectrometer designed to measure hydrocarbon gases in the water column and The University of Georgia's microbial collector. The University of Georgia's rotational sea-floor camera was retrieved as was Specialty Devices storm monitor array. The former was deployed in September and the latter in June, 2006. Both were retrieved by acoustic release from a dispensable weight. Cruise participants also went prepared to recover any and all instruments left on the sea-floor during the September Johnson SeaLink submersible cruise. One of the pore-fluid samplers, a small ''peeper'' was retrieved successfully and in fine condition. Other instrumentation was left on the sea-floor until modifications of the SSD are complete and a return cruise is accomplished.

  20. The upturned concrete beam system : an investigation of structural, environmental, and constructability performance

    E-Print Network [OSTI]

    Young, Hunter A. (Hunter Andrew)

    2009-01-01

    While the recently completed U.S. Federal Building in San Francisco features numerous sustainable aspects that reduce energy demand, the most impressive feature required a distinctive structural floor system. Designers ...

  1. A Sea Floor Survey of the Sleipner Field to Monitor CO2 Migration

    SciTech Connect (OSTI)

    Mark A. Zumberge

    2005-12-31

    In the North Sea natural gas production field at Sleipner, CO{sub 2} is being separated from natural gas and injected into an underground saline aquifer, known as the Utsira formation, for environmental purposes. In this study, gravity measurements were made over the Sleipner CO{sub 2} injection site in 2002 and again in 2005 on top of 30 concrete benchmarks on the seafloor to study the behavior and physical properties of the injected CO{sub 2}. As the gas is injected, pore space water is replaced by gas, altering the bulk density of the formation. This results in a change in gravitational acceleration observed on the overlying sea floor. Our gravity measurements show a repeatability of 4.3 {micro}Gal for 2003 and 3.5 {micro}Gal for 2005. Forward models of the gravity change are calculated based on both 3-D seismic data and reservoir simulation models from other studies. These forward models indicate that the magnitude of maximum gravity change is primarily related to CO{sub 2} density rather than flow geometry. The time-lapse gravity observations best fit a high temperature forward model based on the seismically determined CO{sub 2} geometry, suggesting that the 3-D reflection seismics are imaging the geometry of the injected CO{sub 2}, and that the in situ CO{sub 2} density is around 530 kg/m{sup 3}. Uncertainty in determining the average density using this technique is estimated to be {+-}65 kg/m{sup 3} (95% confidence), however, additional seismic surveys are needed before final conclusions can be drawn. Future gravity measurements will put better constraints on the CO{sub 2} density and continue to map out the CO{sub 2} flow.

  2. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    SciTech Connect (OSTI)

    J. Robert Woolsey; Tom McGee; Carol Lutken; Elizabeth Stidham

    2006-06-01

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Every effort was made to locate and retain the services of a suitable vessel and submersibles or Remotely Operated Vehicles (ROVs) following the storms and the loss of the contracted vessel, the M/V Ocean Quest and its two submersibles, but these efforts have been fruitless due to the demand for these resources in the tremendous recovery effort being made in the Gulf area. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. The seafloor monitoring station/observatory is funded approximately equally by three federal Agencies: Minerals Management Services (MMS) of the Department of the Interior (DOI), National Energy Technology Laboratory (NETL) of the Department of Energy (DOE), and the National Institute for Undersea Science and Technology (NIUST), an agency of the National Oceanographic and Atmospheric Administration (NOAA).

  3. Innovative Design Concept for the New Bangkok International Airport, NBIA 

    E-Print Network [OSTI]

    Kessling, W.; Holst, S.; Schuler, M.

    2004-01-01

    using photovoltaic modules covering a surface area of 55,000 m² for the immediate generation of electric power in combination with an electrically powered compression chiller system was compared to other concepts under the aspect of economy. Fig. 17... that the concept will work even if flight schedules are drastically changed. The building has a maximum cooling demand of 44 MW, where a third is covered by radiant floor cooling, fresh air conditioning and return air cooling respectively. With pre...

  4. A Unit of the University System of Georgia An Equal Education and Employment Opportunity Institution Environmental Health and Safety

    E-Print Network [OSTI]

    Li, Mo

    A Unit of the University System of Georgia An Equal Education and Employment Opportunity Institution Environmental Health and Safety GT Fire Safety Office 955 Fowler Street, 3rd Floor Room 301A

  5. Plancher solaire direct mixte \\`a double r\\'eseau en habitat bioclimatique - Conception et bilan thermique r\\'eel. Double direct solar floor heating in boclimatic habitation - Design and real energetical balance

    E-Print Network [OSTI]

    De Larochelambert, Thierry

    2009-01-01

    This study presents a new direct solar floor heating technique with double heating network wich allows simultaneous use of solar and supply energy. Its main purpose is to store and to diffuse the whole available solar energy while regulating supply energy by physical means without using computer controlled technology. This solar system has been tested in real user conditions inside a bioclimatic house to study the interaction of non-inertial and passive walls on the solar productivity. Daily, monthly and annual energy balances were drawn up over three years and completed by real-time measurements of several physical on-site parameters. As a result the expected properties of this technique were improved. The use of per-hour solar productivity, saved primary energy and corrected solar covering ratio is recommended to analyze the performances of this plant and to allow more refined comparisons with other solar systems

  6. Thermal performance of various multilayer insulation systems below 80K

    SciTech Connect (OSTI)

    Boroski, W.N.; Nicol, T.H.; Schoo, C.J.

    1992-04-01

    The SSC collider dipole cryostat consists of a vacuum shell operating at room temperature, two thermal shields operating near 80K and 20K respectively, and the superconducting magnet assembly operating near 4K. The cryostat design incorporates multilayer insulation (MLI) blankets to limit radiant heat transfer into the 80K and 20K thermal shields. Also, an MLI blanket is used to impede heat transfer through residual gas conduction into the 4K superconducting magnet assembly. A measurement facility at Fermilab has been used to experimentally optimize the thermal insulation system for the dipole cryostat. Previous thermal measurements have been used to define the 80K MLI system configuration and verify system performance. With the 80K MLI system defined, the current effort has focused on experimentally defining the optimum insulation scheme for the 20K thermal shield. The SSC design specification requires that radiant heat transfer be limited to 0.093 W/m[sup 2] at an insulating vacuum of 10[sup [minus]6]torr.

  7. Thermal performance of various multilayer insulation systems below 80K

    SciTech Connect (OSTI)

    Boroski, W.N.; Nicol, T.H.; Schoo, C.J.

    1992-04-01

    The SSC collider dipole cryostat consists of a vacuum shell operating at room temperature, two thermal shields operating near 80K and 20K respectively, and the superconducting magnet assembly operating near 4K. The cryostat design incorporates multilayer insulation (MLI) blankets to limit radiant heat transfer into the 80K and 20K thermal shields. Also, an MLI blanket is used to impede heat transfer through residual gas conduction into the 4K superconducting magnet assembly. A measurement facility at Fermilab has been used to experimentally optimize the thermal insulation system for the dipole cryostat. Previous thermal measurements have been used to define the 80K MLI system configuration and verify system performance. With the 80K MLI system defined, the current effort has focused on experimentally defining the optimum insulation scheme for the 20K thermal shield. The SSC design specification requires that radiant heat transfer be limited to 0.093 W/m{sup 2} at an insulating vacuum of 10{sup {minus}6}torr.

  8. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    SciTech Connect (OSTI)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis; Bob A. Hardage; Jeffrey Chanton; Rudy Rogers

    2006-05-18

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The primary objective of the group has been to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station has always included the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. This possibility has recently achieved reality via the National Institute for Undersea Science and Technology's (NIUST) solicitation for proposals for research to be conducted at the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has achieved a microbial dimension in addition to the geophysical and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments, planned for fall 2005, have had to be postponed and the use of the vessel M/V Ocean Quest and its two manned submersibles sacrificed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Every effort is being made to locate and retain the services of a replacement vessel and submersibles or Remotely Operated Vehicles (ROVs) but these efforts have been fruitless due to the demand for these resources in the tremendous recovery effort being made in the Gulf area. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. The seafloor monitoring station/observatory is funded approximately equally by three federal Agencies: Minerals Management Services (MMS) of the Department of the Interior (DOI), National Energy Technology Laboratory (NETL) of the Department of Energy (DOE), and the National Institute for Undersea Science and Technology (NIUST), an agency of the National Oceanographic and Atmospheric Administration (NOAA). Subcontractors with FY03 funding fulfilled their technical reporting requirements in the previous report (41628R10). Only unresolved matching funds issues remain and will be addressed in the report of the University of Mississippi's Office of Research and Sponsored Programs.

  9. RYCKMAN LECTURE SERIES AND EARTH DAY CELEBRATION Lunch reception to follow, Second Floor, Brauer Hall

    E-Print Network [OSTI]

    Subramanian, Venkat

    used to counter the threat posed by Naegleria fowleri in water distribu- tion systems. The Chlorine Revolution: The Importance of Chlorination, 1908 (Typhoid Fever) to 2014 (Naegleria fowleri) EECE Department

  10. Support of Gulf of Mexico Hydrate Research Consortium: Activities of Support Establishment of a Sea Floor Monitoring Station Project

    SciTech Connect (OSTI)

    J. Robert Woolsey; Thomas McGee; Carol Lutken

    2008-05-31

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research that shared the need for a way to conduct investigations of gas hydrates and their stability zone in the Gulf of Mexico in situ on a more-or-less continuous basis. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (SFO) on the sea floor in the northern Gulf of Mexico, in an area where gas hydrates are known to be present at, or just below, the sea floor and to discover the configuration and composition of the subsurface pathways or 'plumbing' through which fluids migrate into and out of the hydrate stability zone (HSZ) to the sediment-water interface. Monitoring changes in this zone and linking them to coincident and perhaps consequent events at the seafloor and within the water column is the eventual goal of the Consortium. This mission includes investigations of the physical, chemical and biological components of the gas hydrate stability zone - the sea-floor/sediment-water interface, the near-sea-floor water column, and the shallow subsurface sediments. The eventual goal is to monitor changes in the hydrate stability zone over time. Establishment of the Consortium succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among those involved in gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative methods and construct necessary instrumentation. Following extensive investigation into candidate sites, Mississippi Canyon 118 (MC118) was chosen by consensus of the Consortium at their fall, 2004, meeting as the site most likely to satisfy all criteria established by the group. Much of the preliminary work preceding the establishment of the site - sensor development and testing, geophysical surveys, and laboratory studies - has been reported in agency documents including the Final Technical Report to DOE covering Cooperative Agreement DEFC26-00NT40920 and Semiannual Progress Reports for this award, DE-FC26-02NT41628. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in MC118 in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. SFO completion, now anticipated for 2009-10, has, therefore, been delayed. Although delays caused scheduling and deployment difficulties, many sensors and instruments were completed during this period. Software has been written that will accommodate the data that the station retrieves, when it begins to be delivered. In addition, new seismic data processing software has been written to treat the peculiar data to be received by the vertical line array (VLA) and additional software has been developed that will address the horizontal line array (HLA) data. These packages have been tested on data from the test deployments of the VLA and on data from other, similar, areas of the Gulf (in the case of the HLA software). During the life of this Cooperative Agreement (CA), the CMRET conducted many cruises. Early in the program these were executed primarily to survey potential sites and test sensors and equipment being developed for the SFO. When MC118 was established as the observatory site, subsequent cruises focused on this location. Beginning in 2005 and continuing to the present, 13 research cruises to MC118 have been conducted by the Consortium. During September, 2006, the Consortium was able to secure 8 days aboard the R/V Seward Johnson with submersible Johnson SeaLink, a critical chapter in the life of the Observatory project as important documentation, tests, recoveries and deployments were accomplished during this trip (log appended). Consortium members have participated materially in a number of additional cruises including several of the NIUST autonomous underwater vehicle (AUV), Ea

  11. Economic analysis of the daylight-linked lighting control system in office buildings

    SciTech Connect (OSTI)

    Yang, In-Ho; Nam, Eun-Ji [Department of Architectural Engineering, College of Engineering, Dongguk University, 26-3, Pil-dong, Chung-gu, Seoul 100-715 (Korea)

    2010-08-15

    The objective of this study is to perform an economic analysis of the daylight-linked automatic on/off lighting control system installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the energy cost was calculated by using the daylight and building energy analysis simulation. When the lighting control was utilized, an economic analysis was performed using a payback period that was calculated by comparing the initial cost of installing the lighting control system with the annual energy cost which was reduced thanks to the application of the lighting control. The results showed that the lighting energy consumption, when the lighting control was applied, was reduced by an average of 30.5% compared with the case that there was not lighting control applied. Also, the result for total energy consumption showed that, when lighting control was applied, this was reduced by 8.5% when the glazing ratio was 100%, 8.2% for 80%, and 7.6% for 60% when compared to non-application. The payback period was analyzed in terms of the number of floors in a building; 10 floors, 20 floors, 30 floors, and 40 floors. Hence, the building with 40 floors and glazing ratio 100% resulted in the shortest payback period of 8.8 years, the building with 10 floors and glazing ratio 60% resulted in the longest period of 12.7 years. In other words, the larger the glazing ratio and the number of building floors are, the shorter the payback period is. (author)

  12. Underhill Parking Facility is the closest University Lot that is available to the public. Meter machines located on each floor take exact change

    E-Print Network [OSTI]

    Alvarez-Cohen, Lisa

    Parking: Underhill Parking Facility is the closest University Lot that is available to the public. Parking spots fill quickly. Comprehensive map of at UC Berkeley's public parking lots (http://pt.berkeley.edu/parking. Meter machines located on each floor take exact change or credit card. Parking along College Ave. Longer

  13. Psychology Student Affairs -1st Floor Mandler Hall -858.534.3001 -psycadvising@ucsd.edu h#p://psychology.ucsd.edu

    E-Print Network [OSTI]

    Squire, Larry R.

    Psychology Student Affairs - 1st Floor Mandler Hall - 858.534.3001 - psycadvising@ucsd.edu h#p://psychology.ucsd.edu · At least 4 of the Upper Division Psychology Courses MINOR REQUIREMENTS 5 Upper Division 2 Lower Division 6 Upper

  14. Center for Space Research, Conference Room 2.806, WPR Building, 2nd Floor, 3925 W. Braker Lane, Suite 200, Austin, Texas 78759

    E-Print Network [OSTI]

    Lightsey, Glenn

    Center for Space Research, Conference Room 2.806, WPR Building, 2nd Floor, 3925 W. Braker Lane 10 -- 8:30 AM Thermospheric Density Variations, Solar EUV and Geomag. Storm Modeling Bruce R. Bowman, Senior Scientist with Space Environment Technologies Abstract: Discussion of density variations and how

  15. Rigid overlay of volume sonography and MR image data of the female pelvic floor using a fiducial based alignment--feasibility

    E-Print Network [OSTI]

    of the authors [1], advances in 3D sonographical imaging as well as in data acquisition techniques allowRigid overlay of volume sonography and MR image data of the female pelvic floor using a fiducial with enhanced informative content. In this paper, we present an overlay technique of magnetic resonance (MR

  16. NEW YORK UNIVERSITY : DESCRIPTION OF THE PROTEUS SYSTEM

    E-Print Network [OSTI]

    NEW YORK UNIVERSITY : DESCRIPTION OF THE PROTEUS SYSTEM AS USED FOR MUC-5 Ralph Grishman and John Sterling The Proteus Project Computer Science Department New York University 715 Broadway, 7th Floor New, previously developed an d still in use at New York University. The current system, including the Restriction

  17. Thermal stability of radiant black holes

    E-Print Network [OSTI]

    Parthasarathi Majumdar

    2006-04-06

    Beginning with a brief sketch of the derivation of Hawking's theorem of horizon area increase, based on the Raychaudhuri equation, we go on to discuss the issue as to whether generic black holes, undergoing Hawking radiation, can ever remain in stable thermal equilibrium with that radiation. We derive a universal criterion for such a stability, which relates the black hole mass and microcanonical entropy, both of which are well-defined within the context of the Isolated Horizon, and in principle calculable within Loop Quantum Gravity. The criterion is argued to hold even when thermal fluctuations of electric charge are considered, within a {\\it grand} canonical ensemble.

  18. Radiant Heating Basics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Financing Tool FitsProject Developsfor UCNI Reviewing OfficialsRES Las VegasDepartment

  19. Radiant Electric Coop, Inc | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop Inc Jump to:Newberg,Energy LLCALLETEREFU Elektronik GmbH JumpChinaRMRSGmbHElectric

  20. Radiant Technology Corporation RTC | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to:EA EIS Report UrlNM-b < RAPID‎ |RENERCO RenewableRGSRadarEnergy

  1. Low-floor Bus Design Preferences of Walking Aid Users during Simulated

    E-Print Network [OSTI]

    Krovi, Venkat

    . Applied Ergonomics, 10.1016/j.apergo.2012.07.011. A Visual Haptic System for Children with Learning- fessor this August. She is the director of the Ergonomics and Bio- mechanics Lab. Dr. Cavuoto's work and muscle fatigue. The results of this work were recently published in Applied Ergonomics. The outcomes

  2. NON-DESTRUCTIVE DETERMINATION OF SERVICEABILITY AND LOAD BEARING CAPACITY OF FLOOR SLABS USING DYNAMIC METHODS

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    , output-only modal analysis, Frequency Domain Decomposition, system identification, model updating in this case is the verification of the serviceability and the load bearing capacity towards the certification particularly powerful. The big advantage is that the exciting forces need not to be measured. As a consequence

  3. HYDRATE RESEARCH ACTIVITIES THAT BOTH SUPPORT AND DERIVE FROM THE MONITORING STATION/SEA-FLOOR OBSERVATORY, MISSISSIPPI CANYON 118, NORTHERN GULF OF MEXICO

    SciTech Connect (OSTI)

    Lutken, Carol

    2013-07-31

    A permanent observatory has been installed on the seafloor at Federal Lease Block, Mississippi Canyon 118 (MC118), northern Gulf of Mexico. Researched and designed by the Gulf of Mexico Hydrates Research Consortium (GOM-HRC) with the geological, geophysical, geochemical and biological characterization of in situ gas hydrates systems as the research goal, the site has been designated by the Bureau of Ocean Energy Management as a permanent Research Reserve where studies of hydrates and related ocean systems may take place continuously and cooperatively into the foreseeable future. The predominant seafloor feature at MC118 is a carbonate-hydrate complex, officially named Woolsey Mound for the founder of both the GOM-HRC and the concept of the permanent seafloor hydrates research facility, the late James Robert “Bob” Woolsey. As primary investigator of the overall project until his death in mid-2008, Woolsey provided key scientific input and served as chief administrator for the Monitoring Station/ Seafloor Observatory (MS-SFO). This final technical report presents highlights of research and accomplishments to date. Although not all projects reached the status originally envisioned, they are all either complete or positioned for completion at the earliest opportunity. All Department of Energy funds have been exhausted in this effort but, in addition, leveraged to great advantage with additional federal input to the project and matched efforts and resources. This report contains final reports on all subcontracts issued by the University of Mississippi, Administrators of the project, Hydrate research activities that both support and derive from the monitoring station/sea-floor Observatory, Mississippi Canyon 118, northern Gulf of Mexico, as well as status reports on the major components of the project. All subcontractors have fulfilled their primary obligations. Without continued funds designated for further project development, the Monitoring Station/Seafloor Observatory is in danger of lapsing into disuse. However, for the present, interest in the site on the continental slope is healthy and The Center for Marine Resources and Environmental Technology continues to coordinate all activity at the MS/SFO as arranged through the BOEM in 2005. Field and laboratory research projects and findings are reviewed, new technologies and tests described. Many new sensors, systems and two custom ROVs have been developed specifically for this project. Characteristics of marine gas hydrates are dramatically more refined than when the project was initiated and include appear in sections entitled Accomplishments, Products and Publications.

  4. The Ross Biological Reserve Sustainable Building Project MISSION. This project aims to improve teaching, research, and particularly outreach at the Reserve by creating a

    E-Print Network [OSTI]

    Fernández-Juricic, Esteban

    conservation, "net-zero" photovoltaic power, and space for a graduate ecologist-in-residence to coordinate a geothermal heat pump warming a radiant hydronic floor. superinsulating walls and ceilings, shading

  5. DOE Zero Energy Ready Home: Montlake Modern - Seattle, Washington...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ICF-insulated foundation slab edge with R-20 rigid foam under the slab; an air-to-water heat pump plus radiant floor heat; 100% LED lighting; filtered-fan-powered fresh air...

  6. DOE Zero Energy Ready Home Case Study: TC Legend Homes, Bellingham...

    Energy Savers [EERE]

    slab, R-20 rigid foam under slab; radiant floor heat and passive design; air-to-water heat pump COP 4.4; HRV; earth tube ventilation; triple-pane windows, 100% LED. DOE Zero...

  7. DOE Zero Energy Ready Home Case Study: Clifton View Homes, Whidbey...

    Energy Savers [EERE]

    walls, a 10.25-in. SIP roof, and triple-pane windows. The home has a ground-source heat pump provides radiant floor heat plus passive solar heating from large south-facing...

  8. DOE Zero Energy Ready Home Case Study: Clifton View Homes, Whidbey...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    roof, and triple-pane windows. The home has a ground-source heat pump provides radiant floor heat plus passive solar heating from large south-facing windows and bare concrete...

  9. Builders Challenge High Performance Builder Spotlight - Rural Development Inc., Turner Falls, Massachusetts

    SciTech Connect (OSTI)

    2008-01-01

    Building America/Builders Challenge fact sheet on Rural Development Inc, an energy-efficient home builder in cold climate using radiant floor heat, solar hot water, and PV. Examines cost impacts.

  10. DOE Zero Energy Ready Home Case Study: Preferred Builders, Old...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    R-13 closed-cell spray foam under the slab and on basement walls, an ERV, and a gas boiler for forced air and radiant floor heat. BAZeroEnergyReadyPreferredBuilders062414.pdf...

  11. Proposal for the award of a contract for the supply and laying of false floors in the rectifier buildings and the electricity sub-stations serving five LEP access points

    E-Print Network [OSTI]

    1986-01-01

    Proposal for the award of a contract for the supply and laying of false floors in the rectifier buildings and the electricity sub-stations serving five LEP access points

  12. AIR LEAKAGE, SURFACE PRESSURES AND INFILTRATION RATES IN HOUSES

    E-Print Network [OSTI]

    Grimsrud, D.T.

    2011-01-01

    frame construction. floor furnace heating. m floor windows,Gas forced air heating system. 100 m floor area, 230 msolar heating Sealed combustion wood stove. 174 m floor

  13. Cutting sound enhancement system for mining machines

    DOE Patents [OSTI]

    Leigh, Michael C. (Coal Center, PA); Kwitowski, August J. (Clairton, PA)

    1992-01-01

    A cutting sound enhancement system (10) for transmitting an audible signal from the cutting head (101) of a piece of mine machinery (100) to an operator at a remote station (200), wherein, the operator using a headphone unit (14) can monitor the difference in sounds being made solely by the cutting head (101) to determine the location of the roof, floor, and walls of a coal seam (50).

  14. Thermal-Hydraulic Analysis of an Experimental Reactor Cavity Cooling System with Air. Part I: Experiments; Part II: Separate Effects Tests and Modeling

    SciTech Connect (OSTI)

    Corradin, Michael; Anderson, M.; Muci, M.; Hassan, Yassin; Dominguez, A.; Tokuhiro, Akira; Hamman, K.

    2014-10-15

    This experimental study investigates the thermal hydraulic behavior and the heat removal performance for a scaled Reactor Cavity Cooling System (RCCS) with air. A quarter-scale RCCS facility was designed and built based on a full-scale General Atomics (GA) RCCS design concept for the Modular High Temperature Gas Reactor (MHTGR). The GA RCCS is a passive cooling system that draws in air to use as the cooling fluid to remove heat radiated from the reactor pressure vessel to the air-cooled riser tubes and discharged the heated air into the atmosphere. Scaling laws were used to preserve key aspects and to maintain similarity. The scaled air RCCS facility at UW-Madison is a quarter-scale reduced length experiment housing six riser ducts that represent a 9.5° sector slice of the full-scale GA air RCCS concept. Radiant heaters were used to simulate the heat radiation from the reactor pressure vessel. The maximum power that can be achieved with the radiant heaters is 40 kW with a peak heat flux of 25 kW per meter squared. The quarter-scale RCCS was run under different heat loading cases and operated successfully. Instabilities were observed in some experiments in which one of the two exhaust ducts experienced a flow reversal for a period of time. The data and analysis presented show that the RCCS has promising potential to be a decay heat removal system during an accident scenario.

  15. 2 15.10.2013 Van D. BaxterVolker Weinmann Hybrid heat pump system as chance for the

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    pumps Condensing gas and oil boilers DHW tanks Solar panels Under floor heating Installation equipment#12;2 15.10.2013 Van D. BaxterVolker Weinmann Hybrid heat pump system as chance for the renovation market Dipl.-Ing. Volker Weinmann ROTEX Heating Systems GmbH #12;3 15.10.2013 Van D. Baxter

  16. Grand Junction Projects Office Remedial Action Project: Feasibility test of real-time radiation monitoring during removal of surface contamination from concrete floors

    SciTech Connect (OSTI)

    Leino, R.; Corle, S.

    1995-10-01

    This feasibility test was conducted to determine if real-time radiation-monitoring instruments could be mounted on decontamination machines during remediation activities to provide useful and immediate feedback to equipment operators. The U.S. Department of Energy (DOE) sponsored this field test under the Grand Junction Projects Office Remedial Action Project (GJPORAP) to identify a more efficient method to remove radiological contamination from concrete floor surfaces. This test demonstrated that project durations and costs may be reduced by combining radiation-monitoring equipment with decontamination machines. The test also demonstrated that a microprocessor-based instrument such as a radiation monitor can withstand the type of vibration that is characteristic of floor scabblers with no apparent damage. Combining radiation-monitoring equipment with a decontamination machine reduces the time and costs required to decontaminate concrete surfaces. These time and cost savings result from the reduction in the number of interim radiological surveys that must be conducted to complete remediation. Real-time radiation monitoring allows equipment operators to accurately monitor contamination during the decontamination process without support from radiological technicians, which also reduces the project duration and costs. The DOE Grand Junction Projects Office recommends more extensive and rigorous testing of this real-time radiation monitoring to include a variety of surfaces and decontamination machines. As opportunities arise, additional testing will be conducted under GJPORAP.

  17. Results of detailed analyses performed on boring cores extracted from the concrete floors of the Fukushima Daiichi nuclear power plant reactor buildings

    SciTech Connect (OSTI)

    Maeda, Koji; Sasaki, S.; Kumai, M.; Sato, Isamu; Osaka, Masahiko; Fukushima, Mineo; Kawatsuma, Shinji; Goto, Tetsuo; Sakai, Hitoshi; Chigira, Takayuki; Murata, Hirotoshi

    2013-07-01

    Due to the massive earthquake and tsunami on March 11, 2011, and the following severe accident at the Fukushima Daiichi Nuclear Power Plant, concrete surfaces within the reactor buildings were exposed to radioactive liquid and vapor phase contaminants. In order to clarify the situation of this contamination in the reactor buildings of Units 1, 2 and 3, selected samples were transported to the Fuels Monitoring Facility in the Oarai Engineering Center of JAEA where they were subjected to analyses to determine the surface radionuclide concentrations and to characterize the radionuclide distributions in the samples. In particular, penetration of radiocesium in the surface coatings layer and sub-surface concrete was evaluated. The analysis results indicate that the situation of contamination in the building of Unit 2 was different from others, and the protective surface coatings on the concrete floors provided significant protection against radionuclide penetration. The localized penetration of contamination in the concrete floors was found to be confined within a millimeter of the surface of the coating layer of some millimeters. (authors)

  18. Commissioning Trial for Mechanical Ventilation System Installed in Houses 

    E-Print Network [OSTI]

    Ohta, I.; Fukushima, A.

    2004-01-01

    at the bottom of the main unit. Fig. 2 Floor plan and the ventilation system of the model house The ideal air flow pattern of the model house is shown in Figure 3. Each arrow shows the airflow direction...-8588 Summary Airflow rate of a mechanical ventilation system for houses may not exceed the designed or rated airflow rate because of construction problem and lack of maintenance. According to our survey, half of the houses were enjoying less than 50...

  19. Portable, space-saving medical patient support system

    DOE Patents [OSTI]

    Bzorgi; Fariborz (Knoxville, TN)

    2011-02-01

    A support platform having a stowed configuration and a deployed configuration on a floor. The support platform is related to stretcher devices that are used for transporting, confining, or conducting medical procedures on medical patients in medical emergencies. The support platform typically includes a work surface that has a geometric extent. A base that typically includes a plurality of frame members is provided, and the frame members are disposed across the geometric extent of, and proximal to, the work surface in the stowed configuration. The frame members are typically disposed on the floor in the deployed configuration. There is a foldable bracing system engaged with the work surface and engaged with the base. At least a portion of the foldable bracing system is disposed substantially inside at least a portion of the plurality of frame members in the stowed configuration. Further, the foldable bracing system is configured for translocation of the work surface distal from the base in the deployed configuration.

  20. A digital accelerometer array utilizing suprathreshold stochastic resonance for detection of sub-Brownian noise floor accelerations.

    SciTech Connect (OSTI)

    Carr, Dustin Wade; Olsson, Roy H.

    2004-12-01

    The goal of this LDRD project was to evaluate the possibilities of utilizing Stochastic resonance in micromechanical sensor systems as a means for increasing signal to noise for physical sensors. A careful study of this field reveals that in the case of a single sensing element, stochastic resonance offers no real advantage. We have, however, identified a system that can utilize very similar concepts to stochastic resonance in order to achieve an arrayed sensor system that could be superior to existing technologies in the field of inertial sensors, and could offer a very low power technique for achieving navigation grade inertial measurement units.

  1. Engineering Evaluation Report on K-311-1 Floor Subsidence (2008 Annual Report) at the East Tennessee Technology Park, Oak Ridge, Tennessee

    SciTech Connect (OSTI)

    Knott R.B.

    2008-11-13

    The purpose of this task is to evaluate the effect of floor settlement on building structure, piping, and equipment foundations between column lines 1 and 2 and B and K of Bldg. K-311-1 (see Fig. A-1 in Appendix A) at East Tennessee Technology Park (ETTP), Oak Ridge, Tennessee. Revision 0 of this document covers the 2005 annual inspection. Revision 1 addresses the 2006 annual inspection, Revision 2 addresses the 2007 annual inspection, and Revision 3 covers the 2008 annual inspection, as indicated by the changed report title. A civil survey and visual inspection were performed. Only a representative number of points were measured during the 2008 survey. The exact location of a number of survey points in Table A-1 could not be accurately determined in the 2008 survey since these points had not been spray painted since 2003. The points measured are deemed adequate to support the conclusions of this report. Based on the survey and observations, there has been no appreciable change in the condition of the unit since the 2007 inspection. The subsidence of the floor presents concerns to the building structure due to the possible indeterminate load on the pipe gallery framing. Prior to demolition activities that involve the piping or removal of the equipment, such as vent, purge and drain and foaming, engineering involvement in the planning is necessary. The piping connected to the equipment is under stress, and actions should be implemented to relieve this stress prior to disturbing any of the equipment or associated piping. In addition, the load on the pipe gallery framing needs to be relieved prior to any activities taking place in the pipe gallery. Access to this area and the pipe gallery is not allowed until the stress is released.

  2. Behavioral Perspectives on Home Energy Audits: The Role of Auditors, Labels, Reports, and Audit Tools on Homeowner Decision Making

    E-Print Network [OSTI]

    Ingle, Aaron

    2013-01-01

    other  wall  or  floor  heating  systems,  and  heating  other  wall  or  floor  heating  systems,  or  heating  attics,  or  floors,  air  sealing,  heating   system  

  3. SFU Rental Suites Managed by AWM-Alliance Real Estate Group Ltd. Verdant Rental Housing -state of the art Eco-Designed apartments for rent on campus to

    E-Print Network [OSTI]

    , banking, restaurants and other amenities. Energy efficiency includes geothermal heating, laminate flooring bathtubs and modern shower surrounds Added Conveniences · Radiant in-floor heating · SFU University more. The geo- exchange heating will emit 374 fewer tonnes of greenhouse gases per year than a similar

  4. Published June 1, 2003. Distribution restricted to Sponsors until September 1, 2003. auto-id center massachusetts institute of technology, 400 technology sq, building ne46, 6th floor, cambridge, ma 02139-4307, usa

    E-Print Network [OSTI]

    Brock, David

    Program in Logistics at the Massachusetts Institute of Technology and is currently working on MIT Auto corporate logistics and operations management positions. He has a Bachelors of Science in food technology massachusetts institute of technology, 400 technology sq, building ne46, 6th floor, cambridge, ma 02139

  5. Published June 1, 2003. Distribution restricted to Sponsors until September 1, 2003. auto-id center massachusetts institute of technology, 400 technology sq, building ne46, 6th floor, cambridge, ma 02139-4307, usa

    E-Print Network [OSTI]

    Brock, David

    management for the last six years. He was Product Manager at Optimum Logistics, Director of Global Logistics a Master of Engineering in Logistics from the Massachusetts Institute of Technology and a PhD in Solid massachusetts institute of technology, 400 technology sq, building ne46, 6th floor, cambridge, ma 02139

  6. Student Accounting Grace E. Harris Hall Student Service Center 1015 Floyd Ave., 1st Floor P.O. Box 843036 Richmond, VA 23284-3036 (804) 828-2228 Fax (804) 828-5463 www.enrollment.vcu.edu/accounting

    E-Print Network [OSTI]

    Hammack, Richard

    Student Accounting · Grace E. Harris Hall Student Service Center · 1015 Floyd Ave., 1st Floor · P.O. Box 843036 · Richmond, VA 23284-3036 (804) 828-2228 · Fax (804) 828-5463 · www.enrollment.vcu.edu/accounting excess financial aid (not in excess of $200) to any prior academic year charges on my account. 3. I

  7. Student Accounting Grace E. Harris Hall Student Service Center 1015 Floyd Ave., 1st Floor P.O. Box 843036 Richmond, VA 23284-3036 (804) 828-2228 Fax (804) 828-5463 www.enrollment.vcu.edu/accounting

    E-Print Network [OSTI]

    Hammack, Richard

    Student Accounting · Grace E. Harris Hall Student Service Center · 1015 Floyd Ave., 1st Floor · P.O. Box 843036 · Richmond, VA 23284-3036 (804) 828-2228 · Fax (804) 828-5463 · www.enrollment.vcu.edu/accounting-digit routing transit number and your account number. I hereby authorize and request Virginia Commonwealth

  8. Office +27 (0) 21 424 5351 Fax +27 (0) 21 423 4819 Email attorneys@fidfund.co.za Website www.fidfund.co.za Physical 5th Floor, Waalburg Building, 28 Wale Street, Cape Town, 8001, South Africa

    E-Print Network [OSTI]

    Wagner, Stephan

    .fidfund.co.za Physical 5th Floor, Waalburg Building, 28 Wale Street, Cape Town, 8001, South Africa Postal P O Box 3062, Cape Town, 8000, South Africa Docex Docex 154, Cape Town B M Molefe (Chief Executive Officer), A M oorr ee--mmaaiilleedd aapppplliiccaattiioonn ffoorrmmss.. Yours faithfully MR S. AFRICA BURSARY CO

  9. Strategy Guideline: Compact Air Distribution Systems

    SciTech Connect (OSTI)

    Burdick, A.

    2013-06-01

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  10. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 11, 0.11 Specialty systems

    SciTech Connect (OSTI)

    Not Available

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for canopies; loading dock systems; tanks; domes (bulk storage, metal framing); louvers & vents; access floors; integrated ceilings; and mezzanine structures.

  11. Reduction of forest floor respiration by fertilization on both carbon dioxide-enriched and reference 17-year-old

    E-Print Network [OSTI]

    Oren, Ram

    be best applied to aggrading forest systems where soil resources have not been fully exploited (Mikan et affect the available C pool and impact microbial activity. When N amendments are added to peat soils, Canada. Amador JA, Jones RD (1993) Nutrient limitations on microbial respiration in peat soils

  12. he chain of calamity now known as Japan's Triple Disaster began with a massive rupture in the ocean floor.

    E-Print Network [OSTI]

    Anderson, Donald M.

    . At the Fukushima Dai-ichi nuclear power plant, commissioned in 1971 on the coast 140 miles north of Tokyo, reaching heights up to 49 feet. minuTes LaTer In Fukushima, the Dai-ichi nuclear plant withstood shaking nuclear disaster since Chernobyl in 1986. Without their cooling systems, three of the plant's six re

  13. Instability leading to coal bumps and nonlinear evolutionary mechanisms for a coal-pillar-and-roof system

    E-Print Network [OSTI]

    Jiao, Jiu Jimmy

    Instability leading to coal bumps and nonlinear evolutionary mechanisms for a coal mechanisms of the mechanical system that is composed of the stiff hosts (roof and floor) and the coal pillar using catastrophe theory. It is assumed that the roof is an elastic beam and the coal pillar is a strain

  14. Pentek concrete scabbling system: Baseline report; Summary

    SciTech Connect (OSTI)

    NONE

    1997-07-31

    The Pentek concrete scabbling system consists of the MOOSE{reg_sign} scabbler, the SQUIRREL{reg_sign}-I and SQUIRREL{reg_sign}-III scabblers, and VAC-PAC. The scabblers are designed to scarify concrete floors and slabs using cross section, tungsten carbide tipped bits. The bits are designed to remove concrete in 3/8 inch increments. The bits are either 9-tooth or demolition type. The scabblers are used with a vacuum system designed to collect and filter the concrete dust and contamination that is removed from the surface. The safety and health evaluation during the human factors assessment focused on two main areas: noise and dust.

  15. Hospital Energy Benchmarking Guidance - Version 1.0

    E-Print Network [OSTI]

    Singer, Brett C.

    2010-01-01

    cooling, heating systems - Total floor area of hospitalcooling, heating systems - Total floor area of hospitalthe entire floor space served. For example, heating may be

  16. Evaluating Ventilation Systems for Existing Homes

    SciTech Connect (OSTI)

    Aldrich, R.; Arena, L.

    2013-02-01

    During the course of this project, an affordable and high performance ductwork system to directly address the problems of thermal losses, poor efficiency, and air leakage was designed. To save space and enable direct connections between different floors of the building, the ductwork system was designed in such a way that it occupied interior or exterior frame wall cavities. The ductwork system satisfied building regulations for structural support when bridging multiple floors, the spread of fire and smoke, and insulation to reduce the heat flow into or out of the building. Retrofits of urban residential buildings will be the main focus for the application of this ductwork system. Highly reflective foils and insulating materials were used to aid in the increase of the overall R-value of the ductwork itself and the wall assembly. It is expected that the proposed system will increase the efficiency of the HVAC system and the thermal resistance of the building envelope. The performance of the proposed ductwork design was numerically evaluated in a number of different ways. Our results indicate that the duct method is a very cost attractive alternative to the conventional method.

  17. Geothermal System Overview ASHRAE Headquarters Building

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    ,510 sq. ft. · Square footage of floor 2 - 15,290 sq. ft. · Set point for each level - 68ºF Heating, 74ºF Cooling #12;Building Specifics · Heating / cooling area for GSHPs ­ 15,558 sq. ft. ­ All zones on floor 2 and a corridor zone on floor 1 · Heating / cooling area for VRF ­ 18,226 sq. ft. ­ All zones on floor 1 (minus

  18. Roof and Attic Design Guidelines for new and retrofit Construction of Homes in Hot and Coild Climates

    SciTech Connect (OSTI)

    Desjarlais, Andre Omer [ORNL] [ORNL; LaFrance, Marc [International Energy Agency] [International Energy Agency

    2013-01-01

    Some guidelines for improving the energy efficiency of roofs and attics are presented and are based on the research of the DOE Building Technology. The results of combined analytical and experimental studies were used to benchmark computer tools, which in turn, were used to simulate homes in hot and cold climates. Adding floor and roof insulation, above deck ventilation, radiant barriers, cool color shingle, metal or tile roofs, sealing the attic floor, sealing the duct system and sealing the attic were simulated to compute the cost of energy savings. Results are prioritized to help building owners make an informed economic decision when contemplating roof and attic retrofits. Sealing the attic floor is a top retrofit option. The sealed attic approach and a new prototype roof assembly an insulated and ventilated roof are good options for retrofit work but have paybacks ranging from 15 to 25 years. A new sealed attic concept was simulated and computations show its simple payback is about 10 to 12 years in hot and cold climates; its first cost is significantly reduced from that of a spray foam approach. For new construction the best option is to keep the ducts out of the attic, make sure the attic floor is sealed and add at least code level of insulation to the ceiling.

  19. Simulation of radiant cooling performance with evaporative cooling sources

    E-Print Network [OSTI]

    Moore, Timothy

    2008-01-01

    efficient or even net-zero energy buildings and improveddevelopment of net-zero-energy buildings, or something

  20. Simulation of radiant cooling performance with evaporative cooling sources

    E-Print Network [OSTI]

    Moore, Timothy

    2008-01-01

    ft/min), the pressure drop for the heat exchanger is just 50pressure drop associated with the counter-flow indirect-evaporative heat exchanger

  1. Mean Radiant Cooling in a Hot-Humid Climate 

    E-Print Network [OSTI]

    Garrison, M.

    1996-01-01

    normal light weight frame wall construction and significantly below human body temperature. Because the interior walls are cool, the human body will lose heat by radiation to the cooler interior mass walls. The result is an improvement in the bio-climatic...

  2. Non-destructive component separation using infrared radiant energy

    DOE Patents [OSTI]

    Simandl, Ronald F. (Knoxville, TN); Russell, Steven W. (Knoxville, TN); Holt, Jerrid S. (Knoxville, TN); Brown, John D. (Harriman, TN)

    2011-03-01

    A method for separating a first component and a second component from one another at an adhesive bond interface between the first component and second component. Typically the method involves irradiating the first component with infrared radiation from a source that radiates substantially only short wavelengths until the adhesive bond is destabilized, and then separating the first component and the second component from one another. In some embodiments an assembly of components to be debonded is placed inside an enclosure and the assembly is illuminated from an IR source that is external to the enclosure. In some embodiments an assembly of components to be debonded is simultaneously irradiated by a multi-planar array of IR sources. Often the IR radiation is unidirectional. In some embodiments the IR radiation is narrow-band short wavelength infrared radiation.

  3. Thermal Analysis for Ion-Exchange Column System

    SciTech Connect (OSTI)

    Lee, Si Y.; King, William D.

    2012-12-20

    Models have been developed to simulate the thermal characteristics of crystalline silicotitanate ion exchange media fully loaded with radioactive cesium either in a column configuration or distributed within a waste storage tank. This work was conducted to support the design and operation of a waste treatment process focused on treating dissolved, high-sodium salt waste solutions for the removal of specific radionuclides. The ion exchange column will be installed inside a high level waste storage tank at the Savannah River Site. After cesium loading, the ion exchange media may be transferred to the waste tank floor for interim storage. Models were used to predict temperature profiles in these areas of the system where the cesium-loaded media is expected to lead to localized regions of elevated temperature due to radiolytic decay. Normal operating conditions and accident scenarios (including loss of solution flow, inadvertent drainage, and loss of active cooling) were evaluated for the ion exchange column using bounding conditions to establish the design safety basis. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. In-tank modeling results revealed that an idealized hemispherical mound shape leads to the highest tank floor temperatures. In contrast, even large volumes of CST distributed in a flat layer with a cylindrical shape do not result in significant floor heating.

  4. First Floor Records Office, Classroom

    E-Print Network [OSTI]

    Vertes, Akos

    Post O ce Bureau of Internal Revenue FTC Archives Building Federal Bureau of Investigation US Court of Transport. Post O ce Government Printing O ce Lafayette Square Renwick Gallery L'Enfant Plaza FAA NASA

  5. Floor San Francisco, CA 94104

    Broader source: Energy.gov (indexed) [DOE]

    California, consuming an average of 5 billion kWhyr, more than 25 percent of the total electricity consumption for the entire state of New Mexico. 6 It's not just surface water...

  6. Floor San Francisco, CA 94104

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i nA Guide to Tapping into Funding forFY'17 Projects forgray vanGuidelines

  7. Researchers at Montana State University and Idaho National Lab have developed a process to effectively and efficiently clean natural and man-made porous material of radioactive contamination. The system eliminates

    E-Print Network [OSTI]

    Lawrence, Rick L.

    to effectively and efficiently clean natural and man-made porous material of radioactive contamination. The system eliminates the practice of full demolition and removal of contaminated objects and can address contaminated substrate. Thus, building walls (interior or exterior), floors and ceilings can be remediated

  8. How the Library is Organized Floor 1 Floor 2 Floor 3

    E-Print Network [OSTI]

    Fletcher, Robin

    AND to combine terms; use " " around phrases For information on classroom management in middle school "classroom management" and (elementary or middle) For information on inclusive teaching in Grade 4: inclusi

  9. Procedures for extending the storage life of fresh beef for utilization in centralized prepackaging systems 

    E-Print Network [OSTI]

    Quarrier, Doris Evelyn

    1973-01-01

    of transpor- tation. A recent survey (Chain Store Age, 1971) of the nations largest meat packers and supermarket chains revealed that 9X of the super- market chains were purchasing prepackaged retail cuts in 1971 and that these same organizations expected... of labor, equip- ment and floor space in retail markets. The economies resulting from centralized distribution systems include: a reduction in duplication of operations, men and machines; complete utilization of the time and talents of skilled meat...

  10. Advanced Building Efficiency Testbed Initiative/Intelligent Workplace Energy Supply System; ABETI/IWESS

    SciTech Connect (OSTI)

    David Archer; Frederik Betz; Yun Gu; Rong Li; Flore Marion; Sophie Masson; Ming Qu; Viraj Srivastava; Hongxi Yin; Chaoqin Zhai; Rui Zhang; Elisabeth Aslanian; Berangere Lartigue

    2008-05-31

    ABETI/IWESS is a project carried out by Carnegie Mellon's Center for Building Performance and Diagnostics, the CBPD, supported by the U.S. Department of Energy/EERE, to design, procure, install, operate, and evaluate an energy supply system, an ESS, that will provide power, cooling, heating and ventilation for CBPD's Intelligent Workplace, the IW. The energy sources for this system, the IWESS, are solar radiation and bioDiesel fuel. The components of this overall system are: (1) a solar driven cooling and heating system for the IW comprising solar receivers, an absorption chiller, heat recovery exchanger, and circulation pump; (2) a bioDiesel fueled engine generator with heat recovery exchangers, one on the exhaust to provide steam and the other on the engine coolant to provide heated water; (3) a ventilation system including an enthalpy recovery wheel, an air based heat pump, an active desiccant wheel, and an air circulation fan; and (4) various convective and radiant cooling/heating units and ventilation air diffusers distributed throughout the IW. The goal of the ABETI/IWESS project is to demonstrate an energy supply system for a building space that will provide a healthy, comfortable environment for the occupants and that will reduce the quantity of energy consumed in the operation of a building space by a factor of 2 less than that of a conventional energy supply for power, cooling, heating, and ventilation based on utility power and natural gas fuel for heating.

  11. Commissioning Lessons from Study of the Advanced Systems at the CMU Intelligent Workplace 

    E-Print Network [OSTI]

    Claridge, D. E.; Gong, X.

    2008-01-01

    A detailed study has been conducted of the performance of several innovative aspects of the Intelligent Workplace (IW) at Carnegie Mellon University, a low energy consumption building that uses radiant heating, cooling and a desiccant ventilation...

  12. Multi-Wavelength Visible Light Communication System Design Pankil Butala 1a

    E-Print Network [OSTI]

    Little, Thomas

    -converted light emitting diodes, or by filtering to iso- late the blue component from these sources. Multi efficient illumination devices called light emitting diodes (LED). The intensity of radiant flux emitted

  13. Measuring Advances in HVAC Distribution System Design

    SciTech Connect (OSTI)

    Franconi, E.

    1998-05-01

    Substantial commercial building energy savings have been achieved by improving the performance of the HV AC distribution system. The energy savings result from distribution system design improvements, advanced control capabilities, and use of variable-speed motors. Yet, much of the commercial building stock remains equipped with inefficient systems. Contributing to this is the absence of a definition for distribution system efficiency as well as the analysis methods for quantifying performance. This research investigates the application of performance indices to assess design advancements in commercial building thermal distribution systems. The index definitions are based on a first and second law of thermodynamics analysis of the system. The second law or availability analysis enables the determination of the true efficiency of the system. Availability analysis is a convenient way to make system efficiency comparisons since performance is evaluated relative to an ideal process. A TRNSYS simulation model is developed to analyze the performance of two distribution system types, a constant air volume system and a variable air volume system, that serve one floor of a large office building. Performance indices are calculated using the simulation results to compare the performance of the two systems types in several locations. Changes in index values are compared to changes in plant energy, costs, and carbon emissions to explore the ability of the indices to estimate these quantities.

  14. Heat transfer pathways in underfloor air distribution (UFAD) systems

    E-Print Network [OSTI]

    Bauman, F.; Jin, H.; Webster, T.

    2006-01-01

    radiative heat transfer, since radiation was neglectedradiation striking the floor makes up the majority of the total heat transferheat transfer processes: conduction through the slab and floor panels and into the supply plenum via convection; radiation

  15. Science and Engineering of an Operational Tsunami Forecasting System

    SciTech Connect (OSTI)

    Gonzalez, Frank

    2009-04-06

    After a review of tsunami statistics and the destruction caused by tsunamis, a means of forecasting tsunamis is discussed as part of an overall program of reducing fatalities through hazard assessment, education, training, mitigation, and a tsunami warning system. The forecast is accomplished via a concept called Deep Ocean Assessment and Reporting of Tsunamis (DART). Small changes of pressure at the sea floor are measured and relayed to warning centers. Under development is an international modeling network to transfer, maintain, and improve tsunami forecast models.

  16. Science and Engineering of an Operational Tsunami Forecasting System

    ScienceCinema (OSTI)

    Gonzalez, Frank

    2010-01-08

    After a review of tsunami statistics and the destruction caused by tsunamis, a means of forecasting tsunamis is discussed as part of an overall program of reducing fatalities through hazard assessment, education, training, mitigation, and a tsunami warning system. The forecast is accomplished via a concept called Deep Ocean Assessment and Reporting of Tsunamis (DART). Small changes of pressure at the sea floor are measured and relayed to warning centers. Under development is an international modeling network to transfer, maintain, and improve tsunami forecast models.

  17. Mudline subsea wellhead system

    SciTech Connect (OSTI)

    Milberger, L.J.; Thames, E.E.

    1993-08-31

    In a subsea wellhead system, an improved means is described for allowing the well to be drilled with a mudline suspension system and completed with a subsea pressure control system, comprising in combination: an outer wellhead housing for location on a subsea floor, having a lower end adapted to be secured to a conductor pipe extending into the well; conductor connector means for releasably securing a string of conductor riser to the outer wellhead housing to extend to the surface; a cement return port extending through the outer wellhead housing; an inner wellhead housing having a lower end adapted to be secured to a string of outer casing, the inner wellhead housing having a bore containing an internal landing shoulder; outer casing connector means for connecting the inner wellhead housing to outer casing riser and for lowering the outer casing riser and inner wellhead housing through the conductor riser with the inner wellhead housing landing in the outer wellhead housing; seal means for sealing the inner wellhead housing to the outer wellhead housing above the cement return port; a first casing hanger having an internal mudline latch profile; intermediate casing connector means; a second casing hanger having an external latch that latches into the internal mudline latch profile in the first casing hanger; inner casing connector means; and the conductor riser, outer casing riser, intermediate casing riser, and inner casing riser allowing the well to be drilled with a mudline suspension system and pressure control equipment at the surface, the inner casing connector means, intermediate casing connector means, outer casing connector means, and conductor connector means being subsequently releasable to remove the inner casing riser, intermediate casing riser, outer casing riser and conductor riser for subsea pressure control completion.

  18. DOE Zero Energy Ready Home: Leganza Residence - Greenbank, Washington...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    panel (SIPs) walls, a 10.25-inch SIPS roof, an R-20 insulated slab, a 2-ton ground source heat pump, radiant floor heat, 7.1 kWh PV, and triple-pane windows. DOEZEHCliftonViewHom...

  19. A Study of the Advanced Systems at the CMU Intelligent Workplace with an Evaluation of Potential Applications to Texas A&M International University 

    E-Print Network [OSTI]

    Claridge, D. E.; Gong, X.; Verdict, M.; Clingenpeel, K.

    2008-01-01

    A detailed study has been conducted of the performance of several innovative aspects of the Intelligent Workplace (IW) at Carnegie Mellon University, a low energy consumption building that uses radiant heating, cooling and a desiccant ventilation...

  20. Coal-fired high performance power generating system. Quarterly progress report, October 1--December 31, 1992

    SciTech Connect (OSTI)

    Not Available

    1992-12-31

    Our team has outlined a research plan based on an optimized analysis of a 250 MWe combined cycle system applicable to both frame type and aeroderivative gas turbines. Under the constraints of the cycle analysis we have designed a high temperature advanced furnace (FUTAF) which integrates several combustor and air heater designs with appropriate ash management procedures. The Cycle Optimization effort under Task 2 outlines the evolution of our designs. The basic combined cycle approach now includes exhaust gas recirculation to quench the flue gas before it enters the convective air heater. By selecting the quench gas from a downstream location it will be clean enough and cool enough (ca. 300F) to be driven by a commercially available fan and still minimize the volume of the convective air heater. Further modeling studies on the long axial flame, under Task 3, have demonstrated that this configuration is capable of providing the necessary energy flux to the radiant air panels. This flame with its controlled mixing constrains the combustion to take place in a fuel rich environment, thus minimizing the NO{sub x} production. Recent calculations indicate that the NO{sub x} produced is low enough that the SNCR section can further reduce it to within the DOE goal of 0. 15 lbs/MBTU of fuel input. Also under Task 3 the air heater design optimization continued.

  1. 2.1E BDL Summary

    E-Print Network [OSTI]

    Winkelmann, F.C.

    2010-01-01

    FPH HVSYS UHT UVT Floor Panel Heating System Heating andS y s t em Type: Floor Panel Heating System Command KeywordFLOOR-MULTIPLIER BASEBOARD-RATING TROM-VENT-SCH SYSTEM-CONTROL HEATING-

  2. Geographically distributed environmental sensor system

    DOE Patents [OSTI]

    French, Patrick; Veatch, Brad; O'Connor, Mike

    2006-10-03

    The present invention is directed to a sensor network that includes a number of sensor units and a base unit. The base station operates in a network discovery mode (in which network topology information is collected) in a data polling mode (in which sensed information is collected from selected sensory units). Each of the sensor units can include a number of features, including an anemometer, a rain gauge, a compass, a GPS receiver, a barometric pressure sensor, an air temperature sensor, a humidity sensor, a level, and a radiant temperature sensor.

  3. Elev. Elev. 1st Floor, Building 51

    E-Print Network [OSTI]

    Kaji, Hajime

    undergrad, 1st year master's and 1st ~ 2nd year doctroal students University Clinic Nishi-Waseda Office 4th year undergrad, 2nd year master's and 3rd year doctoral students Automatic Certificate-Issuing Macine Next to the Stairs Mon.~Sat.: 9:00~21:00 Locations Issuing Medical Certificates 1st ~ 3rd year

  4. Johannesburg First Floor, 17 Baker Street,

    E-Print Network [OSTI]

    Jarrett, Thomas H.

    and Installation of Rotary UPS, MV Indoor Switchgear and Power Transformers at the MeerKAT site near Carnarvon

  5. Berit Floor Lund Rigorous simulation models

    E-Print Network [OSTI]

    Foss, Bjarne A.

    ingeniør Norwegian University of Science and Technology Faculty of Information Technology, Mathematics, and Electrical Engineering Department of Engineering Cybernetics #12;Norwegian University of Science and Technology Faculty of Information Technology, Mathematics, and Electrical Engineering Department

  6. Formaldehyde Laminate Flooring Clinician Fact Sheet

    E-Print Network [OSTI]

    of the eyes, nose, and throat Skin rashes Cough Shortness of breath Bronchospasm and wheezing, especially

  7. CXD 4600, 9103 Second Floor Refurbishment

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 OutreachProductswsicloudwsiclouddenDVA N C E D B LReports from the CloudGEGR-N Goods POCTBT |CUD-55 /Allen

  8. COMET TA Floor Plan 100225.vc6

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room News PublicationsAudits &BradburyMay 1, 2013, 4:15pmEnergyNovember 12, 2015,and Night |

  9. Floor Support | Stanford Synchrotron Radiation Lightsource

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformation Current HABFES OctoberEvanServices »First ObservationFast(ER1) TargetRLFloor

  10. Model Code for the Prevention of Residential HAC Distribution System Leakage and HAC-Induced Building Leakage, 1994 Edition 

    E-Print Network [OSTI]

    Wemhoff, P.

    1994-01-01

    program, thou h Its attachment by pi Ing Is analo ous to that opan externa11~-mounte8air conditioner. The AD standards are contained in Part 3280, and the HUD regulations in Part 3282, of 24 CFR Ch. XX installed and site-installed space conditioning...C-:+:-- -' plenum chamber. i 2. Enclosed support platforms conta air stream 3. Through-wall, through-floor, and I ceiling returns. (d) Return Air Requirements (e) HUD-Regulated Manufactured Hon Buildings 1. System design. 2 Closure requirements. (0 Air...

  11. Tax Credits, Rebates & Savings | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Solar Energy System and Cogeneration System Personal Property Tax Credit Eligible solar systems Solar energy is defined by D.C. Code 34-1431 to mean "radiant energy, direct,...

  12. Tax Credits, Rebates & Savings | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Energy System and Cogeneration System Personal Property Tax Credit Eligible solar systems Solar energy is defined by D.C. Code 34-1431 to mean "radiant energy, direct,...

  13. DOE-1 USERS GUIDE

    E-Print Network [OSTI]

    Authors, Various

    2011-01-01

    Page 300. FPH - Floor Panel Heating System. able. TPFC - TwoMULTIPUU FLOoR VOl.UME AREA cun SQFT SON1 CUNT HEATING LOAD~ MULTIPLIER FLOOR AREA VOLUME SQFT CUFT SQMT CUIIT HEATING

  14. Vibratory response modeling and verification of a high precision optical positioning system.

    SciTech Connect (OSTI)

    Barraza, J.; Kuzay, T.; Royston, T. J.; Shu, D.

    1999-06-18

    A generic vibratory-response modeling program has been developed as a tool for designing high-precision optical positioning systems. Based on multibody dynamics theory, the system is modeled as rigid-body structures connected by linear elastic elements, such as complex actuators and bearings. The full dynamic properties of each element are determined experimentally or theoretically, then integrated into the program as inertial and stiffness matrices. Utilizing this program, the theoretical and experimental verification of the vibratory behavior of a double-multilayer monochromator support and positioning system is presented. Results of parametric design studies that investigate the influence of support floor dynamics and highlight important design issues are also presented. Overall, good matches between theory and experiment demonstrate the effectiveness of the program as a dynamic modeling tool.

  15. Solar heating and hot water system installed at St. Louis, Missouri. Final report

    SciTech Connect (OSTI)

    Not Available

    1980-04-01

    Information is provided on the solar heating and hot water system installed at the William Tao and Associates, Inc., office building in St. Louis, Missouri. The information consists of description, photos, maintenance and construction problems, final drawing, system requirements and manufacturer's component data. The solar system was designed to provide 50% of the hot water requirements and 45% of the space heating needs for a 900 square foot office space and drafting room. The solar facility has 252 square foot of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.

  16. Low emission U-fired boiler combustion system

    DOE Patents [OSTI]

    Ake, Terence (North Brookfield, MA); Beittel, Roderick (Worcester, MA); Lisauskas, Robert A. (Shrewsbury, MA); Reicker, Eric (Barre, MA)

    2000-01-01

    At least one main combustion chamber contains at least one pulverized coal burner. Each pulverized coal burner is operatively arranged for minimizing NO.sub.X production and for maintaining a predetermined operating temperature to liquefy ash within the combustion chamber. The combustion chamber includes a slag drain for removing slag from the combustion chamber. A slag screen is positioned in a generally U-shaped furnace flow pattern. The slag screen is positioned between the combustion chamber and a radiant furnace. The radiant furnace includes a reburning zone for in-furnace No.sub.X reduction. The reburning zone extends between a reburning fuel injection source and at least one overfire air injection port for injecting air.

  17. Ventilation Systems for Cooling | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    space in your house, putting the insulation on the inside of the roof rather than on the floor of the attic. Sealed attics are more feasible in new home construction, but can be...

  18. Library System Library System

    E-Print Network [OSTI]

    Cinabro, David

    Library System #12;Library System 5150 Anthony Wayne Drive David Adamany Undergraduate Library that for the current fiscal year, we've been given an additional $600,000 for our library materials budget. We're very subscriptions. The Wayne State University Libraries are deeply committed to providing our faculty and students

  19. Establishment of an Environmental Control Technology Laboratory with a Circulating Fluidized-Bed Combustion System

    SciTech Connect (OSTI)

    Wei-Ping Pan; Zhongxian Cheng; Yan Cao; John Smith

    2006-09-30

    This report is to present the progress made on the project entitled ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period July 1, 2006 through September 30, 2006. The following activities have been completed: the steel floor grating around the riser in all levels and the three-phase power supply for CFBC System was installed. Erection of downcomers, loop seals, ash bunker, thermal expansion joints, fuel and bed material bunkers with load cells, rotary air-lock valves and fuel flow monitors is underway. Pilot-scale slipstream tests conducted with bromine compound addition were performed for two typical types of coal. The purposes of the tests were to study the effect of bromine addition on mercury oxidization. From the test results, it was observed that there was a strong oxidization effect for Powder River Basin (PRB) coal. The proposed work for next quarter and project schedule are also described.

  20. Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

    SciTech Connect (OSTI)

    Burdick, A.

    2013-10-01

    This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

  1. PROCEEDINGS, Thirty-Sixth Workshop on Geothermal Reservoir Engineering Stanford University, Stanford, California, January 31 -February 2, 2011

    E-Print Network [OSTI]

    Stanford University

    , a floor deicing system was installed. This consists of a heating grid system placed in the floor emission from the oil burners, I recommended a geothermal solution for the floor and the roof heating.aniko@uni-miskolc.hu ABSTRACT The floor of the entrance tunnel to an underground waste deposit system in Hungary is exposed

  2. DOE ZERH Case Study: Clifton View Homes, Marine Drive and Port Hadlcok, Coupeville and Port Hadlock WA

    SciTech Connect (OSTI)

    none,

    2015-09-01

    Case study of two DOE 2015 Housing Innovation Award winning custom homes in the marine climate that got HERS 39 and 38 without PV or HERS 2-12 and -9 with PV, with 6.5” SIP walls and 10.25” SIP roof; 11.75 ICF around slab, R-20 rigid foam under slab; radiant floor heat and passive design; air-to-water heatpump, fresh air intake with fan, triple-pane windows, 100% LED.

  3. DOE ZERH Case Study: TC Legend Homes, Bellingham Power House, Bellingham, WA

    SciTech Connect (OSTI)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the marine climate that got HERS 34 without PV or HERS -12 with PV, with 6” SIP walls and 10” SIP roof; R-28 ICF around slab, R-20 rigid foam under slab; radiant floor heat and passive design; air-to-water heat pump COP 4.4; HRV; earth tube ventilation; triple-pane windows, 100% LED.

  4. DOE Zero Energy Ready Home Case Study: Leganza Residence - Greenbank, Washington

    SciTech Connect (OSTI)

    none,

    2014-11-01

    This case study describes a DOE Zero Energy Ready Home in Greenbank, Washington that scored HERS 37 without PV and a -5 with PV. This 1,955 ft2 custom home has 6.5-inch structural insulated panel (SIPs) walls, a 10.25-inch SIPS roof, an R-20 insulated slab, a 2-ton ground source heat pump, radiant floor heat, 7.1 kWh PV, and triple-pane windows.

  5. From Shop Floor to Top Floor: Best Business Practices in Energy Efficiency

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Financing Tool Fits the Bill Financing Tool Fits theSunShot Prize: Race to 7-DayEnergyofWork ||

  6. From Shop Floor to Top Floor: Best Business Practices in Energy Efficiency

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LISTStar2-0057-EA Jump to:ofEnia SpAFlex FuelsEnergyInc| Open Energy Information

  7. Assessment of Energy Use and Comfort in Buildings Utilizing Mixed-Mode Controls with Radiant Cooling

    E-Print Network [OSTI]

    Borgeson, Samuel Dalton

    2010-01-01

    a specified range. Degree hours criteria: The time duringin the form of total degree-hours or percent-dissatisfied-s PPD does), so the degree-hours approach would be the most

  8. Global Macrogol 6000 Market Size and Growth up to 2015 : Radiant...

    Open Energy Info (EERE)

    we deeply analyzed the world's main region market conditions that including the product price, profit, capacity, production, capacity utilization, supply, demand and industry...

  9. Assessment of Energy Use and Comfort in Buildings Utilizing Mixed-Mode Controls with Radiant Cooling

    E-Print Network [OSTI]

    Borgeson, Samuel Dalton

    2010-01-01

    Conditioning and the Low Carbon Cooling Challenge. Windsor,Conditioning and the Low Carbon Cooling Challenge. Windsor,occupant comfort and cooling loads in naturally ventilated

  10. Assessment of Energy Use and Comfort in Buildings Utilizing Mixed-Mode Controls with Radiant Cooling

    E-Print Network [OSTI]

    Borgeson, Samuel Dalton

    2010-01-01

    Internal Gains Lighting power density in W/m2: low=7.53, example, both lighting and equipment power density defaultand low lighting and equipment power density values were

  11. Testing hyperalgesia and hypoalgesia in human pain reactivity using shock and radiant heat 

    E-Print Network [OSTI]

    Rhudy, Jamie Lynn

    1998-01-01

    Recent animal studies pose a serious challenge for raphics. current models of pain modulation. These studies have shown that exposure to the same aversive stimulus has opposite effects on different measures of pain reactivity, ...

  12. SpyroCor(tm) Radiant Tube Heater Inserts | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    furnaces. The heaters are long tubes, often in a U shape, which have natural-gas fired burners at one end of the tube (the burner leg) to produce a flame and heated gas that flows...

  13. Multi-pulse operation of a super-radiant backward-wave oscillator

    SciTech Connect (OSTI)

    Bandurkin, I. V. [Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov St., Nizhny Novgorod, 603950 (Russian Federation); Savilov, A. V. [Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov St., Nizhny Novgorod, 603950 (Russian Federation); Lobachevsky State University of Nizhny Novgorod, Nizhny Novgorod (Russian Federation)

    2014-08-15

    Theory of a backward-wave electron oscillator operating in the non-stationary regime of super-radiation of short powerful rf pulses is developed. It is shown that there exist multi-frequency regimes of generation of either two-peak or three-peak output signal with different characteristic frequencies in every peak. The use of such regimes allows increasing the duration, the peak power, and the total energy of the output super-radiation rf pulse.

  14. Practical Analysis of a New Type Radiant Heating Technology in a Large Space Building 

    E-Print Network [OSTI]

    Feng, G.; Cao, G.; Gang, L.

    2006-01-01

    Recently, building energy consumption and total social energy consumption has increased rapidly and non-renewable energy is becoming exhausted. How can we use energy efficiently to respond to rapid increases in building construction, especially...

  15. Assessment of Energy Use and Comfort in Buildings Utilizing Mixed-Mode Controls with Radiant Cooling

    E-Print Network [OSTI]

    Borgeson, Samuel Dalton

    2010-01-01

    to thermal comfort-Occupant behavior and energy use inThe ability to model occupant behavior, particularly windowA literature review of occupant behavior with respect to

  16. Investigation of a radiantly heated and cooled office with an integrated desiccant ventilation unit 

    E-Print Network [OSTI]

    Gong, Xiangyang

    2009-05-15

    compares the heating load and comfort level as measured by uniformity of operative temperature for two different layouts of radiators in the same geometric space. The air exchange rate has been identified as an important factor which affects energy saving...

  17. Assessment of Energy Use and Comfort in Buildings Utilizing Mixed-Mode Controls with Radiant Cooling

    E-Print Network [OSTI]

    Borgeson, Samuel Dalton

    2010-01-01

    simulation model in EnergyPlus. The simulation model wasEnergyPlus 2: Rendering of six zone EnergyPlus model in Sketch-Up. The

  18. Absolute radiant power measurement for the Au M lines of laser...

    Office of Scientific and Technical Information (OSTI)

    (Germany) Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany) Publication Date: 2014-01-15 OSTI Identifier: 22251206 Resource Type: Journal...

  19. Intense Super-radiant X-rays from a Compact Source using a Nanocathode

    Office of Scientific and Technical Information (OSTI)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefieldSulfate Reducing(Journal Article)lasers(JournalatBaBartheExpansion (JournalChemicalNew Metabolic

  20. Intense Super-radiant X-rays from a Compact Source using a Nanocathode

    Office of Scientific and Technical Information (OSTI)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefieldSulfate Reducing(Journal Article)lasers(JournalatBaBartheExpansion (JournalChemicalNew MetabolicArray

  1. Comparison of experimental and analytical methods to evaluate thermal bridges in wall systems

    SciTech Connect (OSTI)

    Desjarlais, A.O. [Oak Ridge National Lab., TN (United States). Energy Div.; McGowan, A.G. [Enermodal Engineering Ltd., Kitchener, Ontario (Canada)

    1997-03-01

    Twelve ASTM C0236 guarded hot box experiments have been performed on wall systems containing a variety of thermal bridges. All of the wall systems included steel framing. Six walls also had a concrete block wall system and a concrete slab to simulate a wall/floor intersection. Thermal bridges included in the wall systems included steel studs, steel tracks, steel stud/track joints, fasteners (steel framing system), concrete slab, metal bolts and angle iron, and brick ties (concrete block wall). Two-dimensional finite difference modeling was also employed to characterize the wall systems. The experimental test data was used to tune and ultimately validate the computer simulation model. The average variation between the tested and simulated wall system R-Values was 3.3% and ranged from {minus}3.4 to +7.4%. The model was then used to determine the thermal impact of each individual thermal bridge. Beside the standard complement of temperature sensors that are traditionally used for these laboratory experiments, additional sensors were installed near each thermal bridge to define the area and magnitude of the thermal distortion caused by the thermal bridge. These thermal bridges were analytically simulated and the additional heat flux due to each thermal bridge was computed. This paper summarizes the experimental and analytical analyses used to characterize the wall systems and concentrate on the thermal impact each type of thermal bridge has on the overall performance of the wall systems.

  2. Opportunities exist to name an entire floor in the Natural History Building. 1st Floor: $3 million | 2nd Floor: $5 million | 3rd Floor: $4 million | 4th Floor: $2 million

    E-Print Network [OSTI]

    Ha, Taekjip

    and film showings. (7,000 students per year) $500,000 · Sedimentology Research Lab: This will be a large laboratory complex that will be the central focus of research and student training in sedimentology. The area

  3. Physical Security and Systems ACCESS REQUEST FORM: CNS and Animal Labs

    E-Print Network [OSTI]

    Boonstra, Rudy

    -8pm 6th Floor - Rear 7th Floor - 24 hours 7th Floor - 7am-8pm CNS: SW227 SW227B SW234 SW235 SW235B SW235C SW235D SW235E SW236 SW236A SW624 Andy Gristock : Signature Required for Animal Facilities Rudy Boonstra : Signature Required for CNS All lab areas include Elevator #3 access Erb/Ito Lab: SW625 SW628 Erb

  4. A Guidebook for Low-Carbon Development at the Local Level

    E-Print Network [OSTI]

    Zhou, Nan

    2012-01-01

    in buildings/m 2 (PV, solar water heaters, geothermal) Thisbuildings/m 2 (PV, solar water heaters, geothermal) Same assolar thermal systems, thermal screens, variable speed drives, and warm air and radiant heaters (

  5. Ductless, Mini-Split Heat Pumps | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to houses with "non-ducted" heating systems, such as hydronic (hot water heat), radiant panels, and space heaters (wood, kerosene, propane). They can also be a good choice for...

  6. Summary Report: Control Strategies for Mixed-Mode Buildings

    E-Print Network [OSTI]

    Brager, Gail; Borgeson, Sam; Lee, Yoonsu

    2007-01-01

    night cooling and ground source heat pumps feeding a slabHVAC GSHP Ground source heat pump. Hydronic geothermal loop.System summary Ground Source Heat Pump; radiant slab heating

  7. SLA-74.0103 No For(:iqri

    Office of Scientific and Technical Information (OSTI)

    Antia ,craft b1issiJ.e (SIAM). A description of the optical system is included, and models of target radiant intensity, atmospheric transmis- sion, and background radiance...

  8. A multi-data comparison of shortwave climate forcing changes E. Palle,1

    E-Print Network [OSTI]

    to Earth's reflectance, in order to assess the observational constraints on the models. We find) and the Clouds and the Earth's Radiant Energy System (CER; accepted 2 September 2005; published 2 November 2005. [1] Traditionally the Earth's reflectance has been

  9. Microfluidic Systems Integrated Microfluidic Systems**

    E-Print Network [OSTI]

    Ismagilov, Rustem F.

    Microfluidic Systems Integrated Microfluidic Systems** Rustem F. Ismagilov* Keywords: analytical methods · enzymes · microfluidics · microreactors · protein structures Microfluidic systems use networks of channels thinner than a human hair to manipulate nanoliter volumes of re- agents. The goal of microfluidics

  10. Development of a deepwater installation and maintenance concept for subsea production systems

    SciTech Connect (OSTI)

    Brancart, C.P.; Henkener, J.A.

    1996-09-01

    Most of the world`s remaining high output petroleum reservoirs tend to be located in the deep ocean. Existing capabilities are challenged for producing oil in 3,000 to 6,000 feet of sea water. It may be possible to extrapolate these existing capabilities for deeper operations but with an associated exponential cost increase. Based on technologies derived from Department of Defense programs, the authors have proposed a subsea completion installation and maintenance concept that requires no mechanical ties between the surface and the bottom of the ocean. Using tetherless underwater vehicles, a modularized subsea completion system can be delivered to the ocean floor, where it is assembled, inter-connected, and tested. The concept is further amplified in the paper.

  11. The fluid dynamics of an underfloor distribution system

    E-Print Network [OSTI]

    Liu, Qing

    2006-01-01

    shadow of a tube is the siphon. Only two-layer strati?cationWater Reservior Flowmeter Siphon Floor Drain Pipe Flowmeterthe plexiglas tank. A siphon pipe with an inner diameter

  12. Alternative Air Conditioning Technologies: Underfloor AirDistribution (UFAD)

    SciTech Connect (OSTI)

    Webster, Tom

    2004-06-01

    Recent trends in today's office environment make it increasingly more difficult for conventional centralized HVAC systems to satisfy the environmental preferences of individual officer workers using the standardized approach of providing a single uniform thermal and ventilation environment. Since its original introduction in West Germany during the 1950s, the open plan office containing modular workstation furniture and partitions is now the norm. Thermostatically controlled zones in open plan offices typically encompass relatively large numbers of workstations in which a diverse work population having a wide range of preferred temperatures must be accommodated. Modern office buildings are also being impacted by a large influx of heat-generating equipment (computers, printers, etc.) whose loads may vary considerably from workstation to workstation. Offices are often reconfigured during the building's lifetime to respond to changing tenant needs, affecting the distribution of within-space loads and the ventilation pathways among and over office partitions. Compounding this problem, there has been a growing awareness of the importance of the comfort, health, and productivity of individual office workers, giving rise to an increased demand among employers and employees for a high-quality work environment. During recent years an increasing amount of attention has been paid to air distribution systems that individually condition the immediate environments of office workers within their workstations to address the issues outlined above. As with task/ambient lighting systems, the controls for the ''task'' components of these systems are partially or entirely decentralized and under the control of the occupants. Typically, the occupant has control over the speed and direction, and in some cases the temperature, of the incoming air supply. Variously called ''task/ambient conditioning,'' ''localized thermal distribution,'' and ''personalized air conditioning'' systems, these systems have been most commonly installed in open-plan office buildings in which they provide supply air and (in some cases) radiant heating directly into workstations. TAC systems can be classified into the following two major categories: (1) furniture-based, and (2) floor-based, underfloor air distribution (UFAD). A large majority of these systems include a raised floor system with which underfloor plenums are used to deliver conditioned air to the space through floor grills, or in conjunction with the workstation furniture and partitions.

  13. Pentek concrete scabbling system: Baseline report; Greenbook (chapter)

    SciTech Connect (OSTI)

    1997-07-31

    The Pentek scabbling technology was tested at Florida International University (FIU) and is being evaluated as a baseline technology. This report evaluates it for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The Pentek concrete scabbling system consisted of the MOOSE, SQUIRREL-I, and SQUIRREL-III scabblers. The scabblers are designed to scarify concrete floors and slabs using cross-section, tungsten carbide tipped bits. The bits are designed to remove concrete in 318 inch increments. The bits are either 9-tooth or demolition type. The scabblers are used with a vacuum system designed to collect and filter the concrete dust and contamination that is removed from the surface. The safety and health evaluation conducted during the testing demonstration focused on two main areas of exposure: dust and noise. Dust exposure was minimal, but noise exposure was significant. Further testing for each of these exposures is recommended. Because of the outdoor environment where the testing demonstration took place, results may be inaccurate. It is feasible that the dust and noise levels will be higher in an enclosed operating environment. Other areas of concern were arm-hand vibration, whole-body vibration, ergonomics, heat stress, tripping hazards, electrical hazards, machine guarding, and lockout/tagout.

  14. Commissioning of a Coupled Earth Tube and Natural Ventilation System at the Acceptance Phase 

    E-Print Network [OSTI]

    Pan, S.; Zheng, M.; Yoshida, H.

    2008-01-01

    the measurement result, the authors found a design fault, which the airflow temperature from floor apertures on the north side was 3 degrees lower than from the floor apertures on the south side. By the use of the CFD (Computational Fluid Dynamics) coupled...

  15. System Effectiveness

    SciTech Connect (OSTI)

    Powell, Danny H; Elwood Jr, Robert H

    2011-01-01

    An effective risk assessment system is needed to address the threat posed by an active or passive insider who, acting alone or in collusion, could attempt diversion or theft of nuclear material. It is critical that a nuclear facility conduct a thorough self-assessment of the material protection, control, and accountability (MPC&A) system to evaluate system effectiveness. Self-assessment involves vulnerability analysis and performance testing of the MPC&A system. The process should lead to confirmation that mitigating features of the system effectively minimize the threat, or it could lead to the conclusion that system improvements or upgrades are necessary to achieve acceptable protection against the threat. Analysis of the MPC&A system is necessary to understand the limits and vulnerabilities of the system to internal threats. Self-assessment helps the facility be prepared to respond to internal threats and reduce the risk of theft or diversion of nuclear material. MSET is a self-assessment or inspection tool utilizing probabilistic risk assessment (PRA) methodology to calculate the system effectiveness of a nuclear facility's MPC&A system. MSET analyzes the effectiveness of an MPC&A system based on defined performance metrics for MPC&A functions based on U.S. and international best practices and regulations. A facility's MC&A system can be evaluated at a point in time and reevaluated after upgrades are implemented or after other system changes occur. The total system or specific subareas within the system can be evaluated. Areas of potential performance improvement or system upgrade can be assessed to determine where the most beneficial and cost-effective improvements should be made. Analyses of risk importance factors show that sustainability is essential for optimal performance. The analyses reveal where performance degradation has the greatest detrimental impact on total system risk and where performance improvements have the greatest reduction in system risk. The risk importance factors show the amount of risk reduction achievable with potential upgrades and the amount of risk reduction actually achieved after upgrades are completed. Applying the risk assessment tool gives support to budget prioritization by showing where budget support levels must be sustained for MC&A functions most important to risk. Results of the risk assessment are also useful in supporting funding justifications for system improvements that significantly reduce system risk.

  16. Effect of squeezing on parameter estimation of gravitational waves emitted by compact binary systems

    E-Print Network [OSTI]

    Ryan Lynch; Salvatore Vitale; Lisa Barsotti; Matthew Evans; Sheila Dwyer

    2014-11-06

    The LIGO gravitational wave (GW) detectors will begin collecting data in 2015, with Virgo following shortly after. The use of squeezing has been proposed as a way to reduce the quantum noise without increasing the laser power, and has been successfully tested at one of the LIGO sites and at GEO in Germany. When used in Advanced LIGO without a filter cavity, the squeezer improves the performances of detectors above about 100 Hz, at the cost of a higher noise floor in the low frequency regime. Frequency-dependent squeezing, on the other hand, will lower the noise floor throughout the entire band. Squeezing technology will have a twofold impact: it will change the number of expected detections and it will impact the quality of parameter estimation for the detected signals. In this work we consider three different GW detector networks, each utilizing a different type of squeezer, all corresponding to plausible implementations. Using LALInference, a powerful Monte Carlo parameter estimation algorithm, we study how each of these networks estimates the parameters of GW signals emitted by compact binary systems, and compare the results with a baseline advanced LIGO-Virgo network. We find that, even in its simplest implementation, squeezing has a large positive impact: the sky error area of detected signals will shrink by about 30% on average, increasing the chances of finding an electromagnetic counterpart to the GW detection. Similarly, we find that the measurability of tidal deformability parameters for neutron stars in binaries increases by about 30%, which could aid in determining the equation of state of neutron stars. The degradation in the measurement of the chirp mass, as a result of the higher low-frequency noise, is shown to be negligible when compared to systematic errors.

  17. Radionuclide calorimeter system

    DOE Patents [OSTI]

    Donohoue, Thomas P. (Denver, CO); Oertel, Christopher P. (Arvada, CO); Tyree, William H. (Boulder, CO); Valdez, Joe L. (Denver, CO)

    1991-11-26

    A circuit for measuring temperature differentials in a calorimeter is disclosed. The temperature differential between the reference element and sample element containing a radioactive material is measured via a wheatstone bridge arrangement of thermistors. The bridge is driven with an alternating current on a pulsed basis to maintain the thermal floor of the calorimeter at a low reference value. A lock-in amplifier connected to the bridge phase locks a signal from the bridge to the input pulsed AC signal to provide a DC voltage. The DC voltage is sampled over time and provided to a digital computer. The digital computer, using curve fitting algorithms, will derive a function for the sample data. From the function, an equilibrium value for the temperature may be calculated.

  18. Radionuclide calorimeter system

    DOE Patents [OSTI]

    Donohoue, T.P.; Oertel, C.P.; Tyree, W.H.; Valdez, J.L.

    1991-11-26

    A circuit for measuring temperature differentials in a calorimeter is disclosed. The temperature differential between the reference element and sample element containing a radioactive material is measured via a Wheatstone bridge arrangement of thermistors. The bridge is driven with an alternating current on a pulsed basis to maintain the thermal floor of the calorimeter at a low reference value. A lock-in amplifier connected to the bridge phase locks a signal from the bridge to the input pulsed AC signal to provide a DC voltage. The DC voltage is sampled over time and provided to a digital computer. The digital computer, using curve fitting algorithms, will derive a function for the sample data. From the function, an equilibrium value for the temperature may be calculated. 7 figures.

  19. Performance evaluation of Automatic Extraction System. Volume V. Geotechnical investigations of the roof conditions in the area mined by the AES machine. Final technical report

    SciTech Connect (OSTI)

    Bieniawski, Z.T.; Rafia, F.; Newman, D.A.

    1980-07-01

    This report presents the results of an in-depth geotechnical investigation aimed at assessing the roof, floor, and coal pillar conditions in the area mined by an experimental Automatic Extraction System (AES), built by National Mine Service Co. The study included diamond core drilling, borescope observations, and detailed engineering geological mapping in Consolidation Coal's McElroy coal mine in West Virginia. The field investigations were accompanied by regional geology studies involving aerial photography and lineament analysis as well as by laboratory testing of 103 rock and coal samples. The roof conditions were interpreted by means of an engineering rock mass classification system, known as the Geomechanics Classification. It was found that the roof quality in the areas mined by the AES machine was poor and that the action of the AES support beams could be detrimental to the overall roof stability. Improvements in the procedures for evaluating future AES-type mining are suggested.

  20. Power system

    DOE Patents [OSTI]

    Hickam, Christopher Dale (Glasford, IL)

    2008-03-18

    A power system includes a prime mover, a transmission, and a fluid coupler having a selectively engageable lockup clutch. The fluid coupler may be drivingly connected between the prime mover and the transmission. Additionally, the power system may include a motor/generator drivingly connected to at least one of the prime mover and the transmission. The power-system may also include power-system controls configured to execute a control method. The control method may include selecting one of a plurality of modes of operation of the power system. Additionally, the control method may include controlling the operating state of the lockup clutch dependent upon the mode of operation selected. The control method may also include controlling the operating state of the motor/generator dependent upon the mode of operation selected.

  1. Impact assessment and performance targets for lighting and envelope systems

    SciTech Connect (OSTI)

    Sullivan, R.; Lee, E.S.; Selkowitz, S.

    1992-06-01

    Electric lighting loads and cooling from solar heat gains and from lights are the two largest components of peak demand in commercial buildings. The most cost effective demand side management solutions are generally those that directly reduce or eliminate these loads. Existing technologies can provide modest reductions, however they are typically applied an a piecemeal manner that yields less than optimal results. The full potential of existing technologies will be realized when they are commercially available in an integrated package easily specifiable by architects and engineers. Emerging technologies can also be developed to provide even greater savings and extend the savings over a greater portion of the building floor area. This report assesses achievable energy and peak demand performance in California commercial buildings with technologies available today and in the future. We characterize energy performance over a large range of building envelope and lighting conditions, both through computer simulation models and through case study measured data, and subsequently determine reasonable energy targets if building design were further optimized with integrated systems of current or new technologies. Energy targets are derived from the study after consideration of industry priorities, design constraints, market forces, energy code influence, and the state of current building stock.

  2. Supplemental information for a notice of construction for the Fueled Clad Fabrication System, the Radioisotope Power Systems Facility, and the Fuel Assembly Area

    SciTech Connect (OSTI)

    Not Available

    1989-08-01

    This ''Notice of Construction'' has been submitted by the US Department of Energy-Richland Operations Office (P.O. Box 550, Richland, Washington 99352), pursuant to WAC 402-80-070, for three new sources of radionuclide emissions at the Hanford Site in Washington State (Figure 1). The three new sources, the Fueled Clad Fabrication System (FCFS) the Radioisotope Power Systems Facility (RPSF) and the Fuel Assembly Area (FAA) will be located in one facility, the Fuels and materials Examination Facility (FMEF) of the 400 Area. The FMEF was originally designed to provide for post- irradiation examination and fabrication of breeder reactor fuels. These FMEF missions were cancelled before the introduction of any fuel materials or any irradiated material. The current plans are to use the facility to fabricate power supplies to be used in space applications and to produce Fast Flux Test Facility (FFTF) fuel and target assemblies. The FCFS and the RPSF will produce materials and assemblies for application in space. The FAA project will produce FFTF fuel and target assemblies. The FCFS and the RPSF will share the same building, stack, and, in certain cases, the same floor space. Given this relationship, to the extent possible, these systems will be dealt with separately. The FAA is a comparatively independent operation though it will share the FMEF complex.

  3. Prevention of significant deterioration permit application for the Fueled Clad Fabrication System, the Radioisotope Power Systems Facility, and the Fuel Assembly Area

    SciTech Connect (OSTI)

    Not Available

    1989-08-01

    This New Source Review'' has been submitted by the US Department of Energy-Richland Operations Office (PO Box 550, Richland, Washington 99352), pursuant to WAC 173-403-050 and in compliance with the Department of Ecology Guide to Processing A Prevention Of Significant Deterioration (PSD) Permit'' for three new sources of radionuclide emissions at the Hanford Site in Washington State. The three new sources, the Fueled Clad Fabrication System (FCFS), the Radioisotope Power Systems Facility (RPSF), and the Fuel Assembly Area (FAA), will be located in one facility, the Fuels and Materials Examination Facility (FMEF) of the 400 Area. The FMEF was originally designed to provide for post-irradiation examination and fabrication of breeder reactor fuels. These FMEF missions were cancelled before the introduction of any fuel materials or any irradiated material. The current plans are to use the facility to fabricate power supplies for use in space applications and to produce Fast Flux Test Facility (FFTF) fuel and target assemblies. The FCFS and the RPSF will produce materials and assemblies for application in space. The FAA project will produce FFTF fuel and target assemblies. The FCFS and the RPSF will share the same building, stack, and, in certain cases, the same floor space. Given this relationship, these systems will be dealt with separately to the extent possible. The FAA is a comparatively independent operation though it will share the FMEF complex.

  4. Battery system

    DOE Patents [OSTI]

    Dougherty, Thomas J; Wood, Steven J; Trester, Dale B; Andrew, Michael G

    2013-08-27

    A battery module includes a plurality of battery cells and a system configured for passing a fluid past at least a portion of the plurality of battery cells in a parallel manner.

  5. Declarative Systems

    E-Print Network [OSTI]

    Condie, Tyson

    2011-01-01

    Google and ibm join in cloud computing research, 2007. [61]task schedulers in a cloud computing system — that we feltturn to the topic of cloud computing [10] and introduce the

  6. Energy Savings Potential of Flexible and Adaptive HVAC Distribution Systems for Office Buildings

    SciTech Connect (OSTI)

    Loftness, Vivian; Brahme, Rohini; Mondazzi, Michelle; Vineyard, Edward; MacDonald, Michael

    2002-06-01

    It has been understood by architects and engineers that office buildings with easily re-configurable space and flexible mechanical and electrical systems are able to provide comfort that increases worker productivity while using less energy. Raised floors are an example of how fresh air, thermal conditioning, lighting needs, and network access can be delivered in a flexible manner that is not ''embedded'' within the structure. What are not yet documented is how well these systems perform and how much energy they can save. This area is being investigated in phased projects of the 21st Century Research Program of the Air-conditioning and Refrigeration Technology Institute. For the initial project, research teams at the Center for Building Performance and Diagnostics, Pittsburgh, Pennsylvania, and Oak Ridge National Laboratory, Oak Ridge, Tennessee, documented the diversity, performance, and incidence of flexible and adaptive HVAC systems. Information was gathered worldwide from journal and conference articles, case studies, manufactured products and assemblies, and interviews with design professionals. Their report thoroughly describes the variety of system types along with the various design alternatives observed for plenums, diffusers, individual control, and system integration. Many of the systems are illustrated in the report and the authors provide quantitative and qualitative comparisons. Among conclusions regarding key design issues, and barriers to widespread adoption, the authors state that flexible and adaptive HVAC systems, such as underfloor air, perform as well if not better than ceiling-based systems. Leading engineers have become active proponents after their first experience, which is resulting in these flexible and adaptive HVAC systems approaching 10 percent of the new construction market. To encourage adoption of this technology that improves thermal comfort and indoor air quality, follow-on work is required to further document performance. Architects, professional engineers, and commercial real estate developers will benefit from the availability of information that quantifies energy savings, first cost construction differences, and additional operating costs created when office space must be reconfigured to accommodate new tenants.

  7. Systems Studies

    SciTech Connect (OSTI)

    Graham, R.L.

    1998-03-17

    The Systems Studies Activity had two objectives: (1) to investigate nontechnical barriers to the deployment of biomass production and supply systems and (2) to enhance and extend existing systems models of bioenergy supply and use. For the first objective, the Activity focused on existing bioenergy markets. Four projects were undertaken: a comparative analysis of bioenergy in Sweden and Austria; a one-day workshop on nontechnical barriers jointly supported by the Production Systems Activity; the development and testing of a framework for analyzing barriers and drivers to bioenergy markets; and surveys of wood pellet users in Sweden, Austria and the US. For the second objective, two projects were undertaken. First, the Activity worked with the Integrated BioEnergy Systems (TBS) Activity of TEA Bioenergy Task XIII to enhance the BioEnergy Assessment Model (BEAM). This model is documented in the final report of the IBS Activity. The Systems Studies Activity contributed to enhancing the feedstock portion of the model by developing a coherent set of willow, poplar, and switchgrass production modules relevant to both the US and the UK. The Activity also developed a pretreatment module for switchgrass. Second, the Activity sponsored a three-day workshop on modeling bioenergy systems with the objectives of providing an overview of the types of models used to evaluate bioenergy and promoting communication among bioenergy modelers. There were nine guest speakers addressing different types of models used to evaluate different aspects of bioenergy, ranging from technoeconomic models based on the ASPEN software to linear programming models to develop feedstock supply curves for the US. The papers from this workshop have been submitted to Biomass and Bioenergy and are under editorial review.

  8. IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, VOL. 5, NO. 6, NOVEMBER 1997 629 Optimal Dispatching Control for Elevator

    E-Print Network [OSTI]

    Cassandras, Christos G.

    ). The cars deliver the passengers and then return empty to the first floor to pick up more passen- gers. We car from the first floor when the number of passengers inside the car reaches or exceeds a threshold the car locations and the number of passengers in each car, such a threshold policy is easily implemented

  9. Department of Systems & Information

    E-Print Network [OSTI]

    Zhigilei, Leonid V.

    , communication systems, control systems, economic systems, energy and environmental systems, human factors systems, safety-critical systems, wireless communications, game theory and artificial intelligenceDeveloping Leaders of Innovation Department of Systems & Information Engineering #12;In the U

  10. Co-Designing Sustainable Communities: The Identification and Incorporation of Social Performance Metrics in Native American Sustainable Housing and Renewable Energy System Design

    E-Print Network [OSTI]

    Shelby, Ryan

    2013-01-01

    Big refrigerators Exercise and Human Power Generation NativeWarmer Floors (No Wood) Human Power Generation Buildingdevelopment by having human power generation Preserve

  11. Co-Designing Sustainable Communities: The Identification and Incorporation of Social Performance Metrics in Native American Sustainable Housing and Renewable Energy System Design

    E-Print Network [OSTI]

    Shelby, Ryan

    2013-01-01

    renewable energy power generation from wind power to provideExercise and Human Power Generation Native Shrubs in theFloors (No Wood) Human Power Generation Building Materials

  12. Design and Analysis ofDesign and Analysis of Mobile SystemsMobile Systems

    E-Print Network [OSTI]

    Wong, Jennifer L.

    Video Games Virtual RealityVirtual Reality Smart Kindergarten (UCLA)Smart Kindergarten (UCLA) #12;3 OverviewGauss--Markov, Probabilistic, City SectionMarkov, Probabilistic, City Section ­­ Group MobilityGroup Mobility Correlated Random) ­­ Position in Destination/Room & Path betweenPosition in Destination/Room & Path between (floor plan grid

  13. Physical Infrastructure Integration for Trinity, ASC L2 Milestone Review

    SciTech Connect (OSTI)

    Sena, Phillip A.

    2015-09-11

    Design, build, and integrate under-floor electrical and water-cooling distribution system for Trinity/ATS-1 platform.

  14. Solar heating and cooling system installed at Leavenworth, Kansas. Final report

    SciTech Connect (OSTI)

    Perkins, R. M.

    1980-06-01

    The solar heating and cooling system installed at the headquarters of Citizens Mutual Savings Association in Leavenworth, Kansas, is described in detail. The project is part of the U.S. Department of Energy's solar demonstration program and became operational in March, 1979. The designer was TEC, Inc. Consulting Engineers, Kansas City, Missouri and contractor was Norris Brothers, Inc., Lawrence, Kansas. The solar system is expected to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2200 square feet. Five, 3-ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3000 gallon chilled water storage tank. Two, 3000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

  15. SLUDGE TREATMENT PROJECT ENGINEERED CONTAINER RETRIEVAL AND TRANSFER SYSTEM PRELMINARY DESIGN HAZARD AND OPERABILITY STUDY

    SciTech Connect (OSTI)

    CARRO CA

    2011-07-15

    This Hazard and Operability (HAZOP) study addresses the Sludge Treatment Project (STP) Engineered Container Retrieval and Transfer System (ECRTS) preliminary design for retrieving sludge from underwater engineered containers located in the 105-K West (KW) Basin, transferring the sludge as a sludge-water slurry (hereafter referred to as 'slurry') to a Sludge Transport and Storage Container (STSC) located in a Modified KW Basin Annex, and preparing the STSC for transport to T Plant using the Sludge Transport System (STS). There are six, underwater engineered containers located in the KW Basin that, at the time of sludge retrieval, will contain an estimated volume of 5.2 m{sup 3} of KW Basin floor and pit sludge, 18.4 m{sup 3} of 105-K East (KE) Basin floor, pit, and canister sludge, and 3.5 m{sup 3} of settler tank sludge. The KE and KW Basin sludge consists of fuel corrosion products (including metallic uranium, and fission and activation products), small fuel fragments, iron and aluminum oxide, sand, dirt, operational debris, and biological debris. The settler tank sludge consists of sludge generated by the washing of KE and KW Basin fuel in the Primary Clean Machine. A detailed description of the origin of sludge and its chemical and physical characteristics can be found in HNF-41051, Preliminary STP Container and Settler Sludge Process System Description and Material Balance. In summary, the ECRTS retrieves sludge from the engineered containers and hydraulically transfers it as a slurry into an STSC positioned within a trailer-mounted STS cask located in a Modified KW Basin Annex. The slurry is allowed to settle within the STSC to concentrate the solids and clarify the supernate. After a prescribed settling period the supernate is decanted. The decanted supernate is filtered through a sand filter and returned to the basin. Subsequent batches of slurry are added to the STSC, settled, and excess supernate removed until the prescribed quantity of sludge is collected. The sand filter is then backwashed into the STSC. The STSC and STS cask are then inerted and transported to T Plant.

  16. Additions, Alterations, and Repairs Introduction Page 8-1 8 Additions, Alterations, and Repairs

    E-Print Network [OSTI]

    conditioned floor area and volume. Converting a garage or unheated basement into a conditioned living space window that extends all the way to the floor and therefore increases both floor area and volume to a building's envelope, space-conditioning system, water-heating system or lighting system

  17. Development of a waste dislodging and retrieval system for use in the Oak Ridge National Laboratory gunite tank

    SciTech Connect (OSTI)

    Randolph, J.D.; Lloyd, P.D.; Burks, B.L.

    1997-03-01

    As part of the Gunite And Associated Tanks (GAAT) Treatability Study the Oak Ridge National Laboratory (ORNL) has developed a tank waste retrieval system capable of removing wastes varying from liquids to thick sludges. This system is also capable of scarifying concrete walls and floors. The GAAT Treatability Study is being conducted by the Department of Energy Oak Ridge Environmental Restoration Program. Much of the technology developed for this project was cosponsored by the DOE Office of Science and Technology through the Tanks Focus Area (TFA) and the Robotics Technology Development Program. The waste dislodging and conveyance (WD&C) system was developed jointly by ORNL and participants from the TFA. The WD&C system is comprised of a four degree-of-freedom arm with back driveable motorized joints. a cutting and dislodging tool, a jet pump and hose management system for conveyance of wastes, confined sluicing end-effector, and a control system, and must be used in conjunction with a robotic arm or vehicle. Other papers have been submitted to this conference describing the development and operation of the arm and vehicle positioning systems. This paper will describe the development of the WD&C system and its application for dislodging and conveyance of ORNL sludges from the GAAT tanks. The confined sluicing end-effector relies on medium pressure water jets to dislodge waste that is then pumped by the jet pump through the conveyance system out of the tank. This paper will describe the results of cold testing of the integrated system. At the conference presentation there will also be results from the field deployment. ORNL has completed fabrication of the WD&C system for waste removal and is full-scale testing, including testing of the confined sluicing end-effector.

  18. Human Resources Office Dalia Bldg. 2nd Floor,

    E-Print Network [OSTI]

    of soil conservation and water harvesting interventions. Design and evaluate soil and water conservation.icarda.org Post-doctoral Fellow Soil and Water Conservation Position specification Post-doctoral Fellow Reports to: Director, Integrated Water and Land Management Program (IWLMP) Location: Amman, Jordan. Closing date: 12

  19. Accelerated Wear Tests on Common Floor-covering Materials. 

    E-Print Network [OSTI]

    Stewart, B. R.; Kunze, O. R.; Hobgood, Price.

    1958-01-01

    This dissertation examines the performance of an ensemble Kalman filter (EnKF) implemented in a mesoscale model in increasingly realistic contexts from under a perfect model assumption and in the presence of significant ...

  20. First Floor Interim Plan: January,2008 Draft: 28 February 2008

    E-Print Network [OSTI]

    Walker, Henry MacKay

    Visitor 1207 Bio Off Hinsa 1208 Bio Lab Freezer 1209 Bio Lab Radio- isotopes 1004 Bio Lab Animal Bio Phy Fac Res Case 1035 Phy Lab Optic Laser 1133 Phy Lab Waves 1231 Phy Lab Nuclear 1236 Phy Adv Lab 1133A Phy Lab Mod / Waves 1133B Phy Lab Mod / Waves 1231A Phy Lab Mod / Waves 1321 Phy Study 1233 Phy

  1. First Floor Interim Plan: Fall,2007 Draft: 13 August 2007

    E-Print Network [OSTI]

    Walker, Henry MacKay

    Bio Off Hinsa 1208 Bio Lab Freezer 1209 Bio Lab Radio- isotopes 1004 Bio Lab Animal Bio / Phys Develop 1039 Phy Off Case 1038 Phy Fac Res Case 1035 Phy Lab Optic Laser 1133 Phy Lab Waves 1231 Phy Lab Nuclear 1236 Phy Adv Lab 1133A Phy Lab Mod / Waves 1133B Phy Lab Mod / Waves 1231A Phy Lab Mod / Waves

  2. Savings Project: Insulate and Air Seal Floors Over Unconditioned...

    Broader source: Energy.gov (indexed) [DOE]

    insulation Wire fasteners Tape measure Sharp utility knife Caulk and foam sealant Caulk gun Stepladder Straightedge Respirator or dust mask Eye protection Protective clothing,...

  3. Characterizing the muscle architecture in cadaveric female pelvic floor muscles

    E-Print Network [OSTI]

    Nguyen, Olivia Thuy-Minh

    2012-01-01

    A. Ashton-Miller. "Levator Ani Muscle Stretch Induced byComparison of Levator Ani Muscle Defects and Function inMRI Comparison of Levator Ani Structure, Volume, and

  4. Working Towards 100% Electronic Transactions on the Shop Floor 

    E-Print Network [OSTI]

    Terwilliger, M.

    1985-01-01

    ~ will have to deal with to succeed. The three companies are General Motors, General Electric, and IBM, and the three major issues are: 1. Building a comprehensive manufucturing!strat egy, not a piece-meal, approach. 2. Building a corporate manufacturing... to strategy planning technique and not to reality. As a result, we will witness one of the largest re-positioning periods in corporate manufacturing history. PLANNING FOR THE FUTURE IBM, like GM and GE, has moved through a consider able period...

  5. International Flooring Conference 26 March 2009, Changzhou, China

    E-Print Network [OSTI]

    , China Main sources of information W W W W W W W W W W W W · UNECE/FAO Forest Products Annual Market by European Forest Institute · US Foreign Agricultural Statistics · Chinese Customs · State Forestry Agency, China · International Wood Markets Group · European Federation of the Parquet Industry Main sources

  6. Indentation and Recovery Tests of Common Resilient Floor Coverings. 

    E-Print Network [OSTI]

    Stewart, B. R.; Kunze, O. R.; Hobgood, Price

    1960-01-01

    Gas-cooled nuclear reactors have been receiving specific attention for Generation IV possibilities due to desired characteristics such as relatively low cost, short construction period, and inherent safety. Attractive ...

  7. Indentation and recovery characteristics of common resilient floor coverings 

    E-Print Network [OSTI]

    Stewart, Billy Ray

    1959-01-01

    ?ate'ties At tbe ' Tesperstnres of 50 p an4 11 p. . . . . . ' hf l . Xg, Typical indentation ebd aeooverp corrie af Robber Tile, Vinyl Tile ead Viayl?' Asbestos Tile ~ ' ~ ' ~ ~ ' ~ ~ ' ~ ~ ~ ~ ' ~ "a' ~ ~ ~ ', ~ do" ' l la;: Tppioe1 xsdestotios . end... . . . Rmhagasnsl ~ "r C . I prefect Qhs pi the genes Agricultural ggperiaent gtstion '-entitled &%'ho Desirability of Wetiridle end Methods of is- ' a?-' stslletioa for tloir Coverings, , Drainboard surfaces, yleor snd gall Piaiehes', ead gall. Co...

  8. ECE Graduate Student Affairs Engineering Building I, 2nd Floor

    E-Print Network [OSTI]

    Siegel, Paul H.

    , Applied Additional Courses Electromagnetic Theory - Electromagnetics and Computational Methods Coursework (twenty units) SIO 214 A Introduction to Fluid Mechanics Core Courses SIO 202 A-B Fundamentals for Electromagnetics, Advanced Antenna Design ECE 250 Random Processes Total: 12 Units ECE 251 A-B-C-D1 Digital Signal

  9. Entropy "floor" and effervescent heating of intracluster gas

    E-Print Network [OSTI]

    Roychowdhury, S; Nath, B B; Begelman, M C; Begelman, Mitchell C.

    2004-01-01

    Recent X-ray observations of clusters of galaxies have shown that the entropy of the intracluster medium (ICM), even at radii as large as half the virial radius, is higher than that expected from gravitational processes alone. This is thought to be the result of nongravitational processes influencing the physical state of the ICM. In this paper, we investigate whether heating by a central AGN can explain the distribution of excess entropy as a function of radius. The AGN is assumed to inject buoyant bubbles into the ICM, which heat the ambient medium by doing pdV work as they rise and expand. Several authors have suggested that this "effervescent heating" mechanism could allow the central regions of clusters to avoid the ``cooling catastrophe''. Here we study the effect of effervescent heating at large radii. Our calculations show that such a heating mechanism is able to solve the entropy problem. The only free parameters of the model are the time-averaged luminosity and the AGN lifetime. The results are main...

  10. Entropy "floor" and effervescent heating of intracluster gas

    E-Print Network [OSTI]

    S. Roychowdhury; M. Ruszkowski; B. B. Nath; Mitchell C. Begelman

    2004-07-08

    Recent X-ray observations of clusters of galaxies have shown that the entropy of the intracluster medium (ICM), even at radii as large as half the virial radius, is higher than that expected from gravitational processes alone. This is thought to be the result of nongravitational processes influencing the physical state of the ICM. In this paper, we investigate whether heating by a central AGN can explain the distribution of excess entropy as a function of radius. The AGN is assumed to inject buoyant bubbles into the ICM, which heat the ambient medium by doing pdV work as they rise and expand. Several authors have suggested that this "effervescent heating" mechanism could allow the central regions of clusters to avoid the ``cooling catastrophe''. Here we study the effect of effervescent heating at large radii. Our calculations show that such a heating mechanism is able to solve the entropy problem. The only free parameters of the model are the time-averaged luminosity and the AGN lifetime. The results are mainly sensitive to the total energy injected into the cluster. Our model predicts that the total energy injected by AGN should be roughly proportional to the cluster mass. The expected correlation is consistent with a linear relation between the mass of the central black hole(s) and the mass of the cluster, which is reminiscent of the Magorrian relation between the black hole and bulge mass.

  11. Second Floor Interim Plan: January,2008 Draft: 28 February 2008

    E-Print Network [OSTI]

    Walker, Henry MacKay

    Gas Storage 2214 Gas Storage 2114 Chem Fac Res Marzluff 2113 Chem Fac Res Mobley 2605 Chem Fac Res Off Sharpe 2024 Chem Classroom 2023 Chem Prep 2022 Chem Classroom 2021 Bio Classroom 2234 Chem Storage

  12. Second Floor Interim Plan: Fall,2007 Draft: 10 August 2007

    E-Print Network [OSTI]

    Walker, Henry MacKay

    .Chem Lab 2331 Chem Intro/Org Lab Instrumentation 2331A Telecom 2213 Gas Storage 2214 Gas Storage 2114 Chem Chem Prep 2022 Chem Classroom 2021 Bio Classroom 2234 Chem Storage 2133 Organic Chem Lab 2134 Intro

  13. Second Floor Interim Plan: Summer,2007 Draft: 6 April 2007

    E-Print Network [OSTI]

    Walker, Henry MacKay

    Intro.Chem Lab 2331 Chem Intro/Org Lab Instrumentation 2331A Telecom 2213 Gas Storage 2214 Gas Storage 2008 Chem Fac Res Lyons 2806 StckrmOff Campbell then Math Off Visitor 2807 Chem Glassware Storage 2809 Classroom 2023 Chem Prep 2022 Chem Classroom 2021 Bio Classroom 2234 Chem Storage 2133 Organic Chem Lab 2134

  14. New CMI process recycles magnets from factory floor | The Ames...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    waste and creates useful magnets out of it. Efficient waste-recovery methods for rare-earth metals are one way to reduce demand for these limited mined resources. The process,...

  15. New CMI process recycles magnets from factory floor | The Ames...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the rare-earth metals for reuse. But CMI scientist Ikenna Nlebedim said he and co-inventor Bill McCallum wanted to push further. "We decided to see if there is a possibility of...

  16. Exploring abundance under the sea floor By Alvin Powell

    E-Print Network [OSTI]

    Girguis, Peter R.

    instruments designed to take measurements there. Girguis and research associate Scott Wankel, who describe

  17. Accessibility Building Name Grid to the ground floor

    E-Print Network [OSTI]

    Lawson, Catherine L.

    Cogeneration Plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F3 J Busch Dining Hall

  18. Financial Services and Operations 2nd Floor Lakeshore Center

    E-Print Network [OSTI]

    or type The number below is: Individual Taxpayer ID No. (ITIN) Social Security No. Federal Employer ID No

  19. Property:Building/FloorAreaChurchesChapels | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)Energy Technology JumpWilliamDRAFTArea

  20. Property:Building/FloorAreaMiscellaneous | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)Energy

  1. Recycling Magnets from the Factory Floor | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefieldSulfateSciTechtail.Theory ofDid youOxygen Generation |Publications The NRELRequirementsRecycling

  2. Savings Project: Insulate and Air Seal Floors Over Unconditioned Garages |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative FuelsofProgram: Report AppendicesA TokenCommercialSTEMSarah L.Department of Energy

  3. Gasification system

    DOE Patents [OSTI]

    Haldipur, Gaurang B. (Hempfield, PA); Anderson, Richard G. (Penn Hills, PA); Cherish, Peter (Bethel Park, PA)

    1983-01-01

    A method and system for injecting coal and process fluids into a fluidized bed gasification reactor. Three concentric tubes extend vertically upward into the fluidized bed. Coal particulates in a transport gas are injected through an inner tube, and an oxygen rich mixture of oxygen and steam are injected through an inner annulus about the inner tube. A gaseous medium relatively lean in oxygen content, such as steam, is injected through an annulus surrounding the inner annulus.

  4. Gasification system

    DOE Patents [OSTI]

    Haldipur, Gaurang B. (Hempfield, PA); Anderson, Richard G. (Penn Hills, PA); Cherish, Peter (Bethel Park, PA)

    1985-01-01

    A method and system for injecting coal and process fluids into a fluidized bed gasification reactor. Three concentric tubes extend vertically upward into the fluidized bed. Coal particulates in a transport gas are injected through an inner tube, and an oxygen rich mixture of oxygen and steam are injected through an inner annulus about the inner tube. A gaseous medium relatively lean in oxygen content, such as steam, is injected through an annulus surrounding the inner annulus.

  5. Directives System

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1998-01-30

    The Department of Energy (DOE) Directives System is the means by which DOE policies, requirements, and responsibilities are developed and communicated throughout the Department. Directives are used to inform, direct, and guide employees in the performance of their jobs, and to enable employees to work effectively within the Department and with agencies, contractors, and the public. Cancels: DOE O 251.1, DOE M 251.1-1

  6. Power Systems Engineering

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    systems; steam, water, fuel, and environmental monitoring systems; alternative energy systems; reliability, availability, and maintainability assessments; and associated...

  7. Braking system

    DOE Patents [OSTI]

    Norgren, D.U.

    1982-09-23

    A balanced braking system comprising a plurality of braking assemblies located about a member to be braked. Each of the braking assemblies consists of a spring biased piston of a first material fitted into a body of a different material which has a greater contraction upon cooling than the piston material. The piston is provided with a recessed head portion over which is positioned a diaphragm and forming a space therebetween to which is connected a pressurized fluid supply. The diaphragm is controlled by the fluid in the space to contact or withdraw from the member to be braked. A cooling means causes the body within which the piston is fitted to contract more than the piston, producing a tight shrink fit therebetween. The braking system is particularly applicable for selectively braking an arbor of an electron microscope which immobilizes, for example, a vertically adjustable low temperature specimen holder during observation. The system provides balanced braking forces which can be easily removed and re-established with minimal disturbance to arbor location.

  8. Accelerator Systems

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room News Publications Traditional Knowledge KiosksAbout UsAbout NewAccelerator Systems Accelerator

  9. File Systems

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformation Current HABFES OctoberEvan Racah861MayArtQuestionsFieldFiji Fiji IsFile Systems

  10. A flexible assembly system for low volume and high diversity production

    E-Print Network [OSTI]

    Schwenke, Richard Clemens

    2009-01-01

    This thesis project seeks to optimize floor layouts for semiconductor equipment assembly operations. The assembly of semiconductor equipment is characterized by low volume and high product diversity and complexity. Demand ...

  11. Light weight and economical exhaust heat exchanger for waste heat recovery using mixed radiant and convective heat transfer

    Broader source: Energy.gov [DOE]

    A hybrid heat exchanger is designed to keep highly stressed materials around the working fluid at a moderate temperature so that it can operate at higher working fluid pressure.

  12. Performance Testing of Radiant Barriers (RB) with R11, R19, and R30 Cellulose and Rock Wool Insulation 

    E-Print Network [OSTI]

    Hall, J. A.

    1988-01-01

    In the sumner testlng (3 R-values, 2 Insulatlon types, and 2 test conf lguratlons--no RB and RBT), thf Latin Square deslgn used In the prevlous TVA testlng could no be used. Instead. a split-spllt-plot test deslgn was chosen (see table 1). Thls design.... The emisslvlty of both sldes of thls RB was approxlmately 0.05. Because of the large number of varlables to be studled In the sumner (3 R-values, 2 types of Insulatlon. 2 attlc conf lguratlons--no RB and RBR), only the RBR was tested In the sumner. With a...

  13. Comparative Testing of the Combined Radiant Barrier and Duct Models in the ESL's Code-Compliant Simulation Model 

    E-Print Network [OSTI]

    Kim, S.; Haberl, J. S.

    2007-07-10

    model and the EnergyGauge program by the Florida Solar Energy Center (FSEC). Sensitivity analyses were performed by varying duct insulation level, supply duct area, return duct area, supply duct leakage, return duct leakage, and ceiling insulation levels...

  14. Calibration of the Accuscan II In Vivo System for I-125 Thyroid Counting

    SciTech Connect (OSTI)

    Ovard R. Perry; David L. Georgeson

    2011-07-01

    This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-125 thyroid counting. The source used for the calibration was a DOE manufactured Am-241/Eu-152 source contained in a 22 ml vial BEA Am-241/Eu-152 RMC II-1 with energies from 26 keV to 344 keV. The center of the detector housing was positioned 64 inches from the vault floor. This position places the approximate center line of the detector housing at the center line of the source in the phantom thyroid tube. The energy and efficiency calibration were performed using an RMC II phantom (Appendix J). Performance testing was conducted using source BEA Am-241/Eu-152 RMC II-1 and Validation testing was performed using an I-125 source in a 30 ml vial (I-125 BEA Thyroid 002) and an ANSI N44.3 phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-125 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  15. Calibration of the Accuscan II In Vivo System for I-131 Thyroid Counting

    SciTech Connect (OSTI)

    Orval R. Perry; David L. Georgeson

    2011-07-01

    This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-131 thyroid counting. The source used for the calibration was an Analytics mixed gamma source 82834-121 distributed in an epoxy matrix in a Wheaton Liquid Scintillation Vial with energies from 88.0 keV to 1836.1 keV. The center of the detectors was position 64-feet from the vault floor. This position places the approximate center line of the detectors at the center line of the source in the thyroid tube. The calibration was performed using an RMC II phantom (Appendix J). Validation testing was performed using a Ba-133 source and an ANSI N44.3 Phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibrations including verification counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-131 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  16. Water gate array for current flow or tidal movement pneumatic harnessing system

    DOE Patents [OSTI]

    Gorlov, Alexander M. (Brookline, MA)

    1991-01-01

    The invention, which provides a system for harnessing power from current flow or tidal movement in a body of water, comprises first and second hydro-pneumatic chambers each having ingress and egress below the water surface near the river or ocean floor and water gates operative to open or seal the ports to the passage of water. In an exemplary embodiment, the gates are sychronized by shafts so that the ingress ports of each chamber are connected to the egress ports of each other chamber. Thus, one set of gates is closed, while the other is open, thereby allowing water to flow into one chamber and build air pressure therein and allowing water to flow out of the other chamber and create a partial vacuum therein. A pipe connects the chambers, and an air turbine harnesses the air movement within the pipe. When water levels are equilibrated, the open set of gates is closed by a counterweight, and the other set is allowed to open by natural force of the water differential. The water gates may be comprised of a plurality of louvers which are ganged for simultaneous opening and closing. The system is designed to operate with air turbines or other pneumatic devices. Its design minimizes construction cost and environmental impact, yet provides a clean renewable energy source.

  17. DALHOUSIE UNIVERSITY Fire Protection Design Guidelines Nov 2013

    E-Print Network [OSTI]

    Brownstone, Rob

    that other options such as installing a dry pipe system or heating the area would be prohibitively expensive switch and a drain valve installed on each floor for ease of floor isolation. Associated

  18. Self-Guided Walking Tour This self-guided walking tour will take about one hour to

    E-Print Network [OSTI]

    . Your starting point, [A], is on the ground floor lobby of the Recreation, Athletics & Wellness Centre if you wish. (By the way, buried underneath the football field is a geothermal heating and cooling system apartment floor or townhouse ro

  19. Department of Facilities Management C: Compliant Rev. 0 Dated Feb. 28 `09

    E-Print Network [OSTI]

    Brownstone, Rob

    it can be demonstrated that other options such as installing a dry pipe system or heating the area would valve, and flow switch and a drain valve installed on each floor for ease of floor isolation. Associated

  20. Transfer system

    DOE Patents [OSTI]

    Kurosawa, Kanji (Tokyo, JP); Koga, Bunichiro (Miyagi, JP); Ito, Hideki (Miyagi, JP); Kiriyama, Shigeru (Miyagi, JP); Higuchi, Shizuo (Kanagawa, JP)

    2003-05-20

    A transport system includes a traveling rail (1) which constitutes a transport route and a transport body (3) which is capable of traveling on the traveling rail in the longitudinal direction of the traveling rail. Flexible drive tubes (5) are arranged on the traveling rail in the longitudinal direction of the traveling rail. The transport body includes a traveling wheel (4) which is capable of rolling on the traveling rail and drive wheels (2) which are capable of rolling on the drive tubes upon receiving the rotational drive power generated by pressure of a pressure medium supplied to the drive tubes while depressing the drive tubes. The traveling rail includes a plurality of transport sections and the transport body is capable of receiving a rotational drive force from the drive tubes at every transport sections. If necessary, a transport route changeover switch which changes over the transport route can be provided between the transport sections.

  1. A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building

    E-Print Network [OSTI]

    2013-01-01

    =5.5 (designed for single floor) Heating Sizing Heating from110°F) due to heating from floor Minimum volume set at 5% tofloor) ASHRAE 90.1-2001 Lighting Equipment (plug loads) Fans Pumps/Cooling tower Cooling Fan powered boxes Total (kWh/ft -yr) Heating

  2. DOE Zero Energy Ready Home Case Study: Montlake Modern - Seattle, Washington

    SciTech Connect (OSTI)

    none,

    2014-11-01

    This case study describes a DOE Zero Energy Ready Home in Seattle, WA, that scored HERS 42 without PV and a -1 with PV. This 3,192 ft2 custom home has 6-inch SIP walls, a 12-inch SIP roof, an R-28 ICF-insulated foundation slab edge with R-20 rigid foam under the slab; an air-to-water heat pump plus radiant floor heat; 100% LED lighting; filtered-fan-powered fresh air intake; triple-pane windows, 9.7 kWh PV for electric car charging station.

  3. Cost-Effective Energy Efficiency Measures for Above Code (ASHRAE 90.1-2001 and 2007) Small Retail Buildings in the City of Arlington (Presentation) (Revised) , Energy Systems Laboratory, Texas A&M University. 

    E-Print Network [OSTI]

    Kim, H.; Do, S; Kim, K.; Baltazar, J. C.; Haberl, J.; Lewis, C.

    2011-01-01

    .) CoA Aspect Ratio PNNL 20405:ASHRAE 90.1-2010 245 ft (L) X 61 ft (W) Number of Floors PNNL 20405:ASHRAE 90.1-2010 Floor-to-Floor Height (ft.) PNNL 20405:ASHRAE 90.1-2010 Floor-to-Ceiling Height = 17 ft Orientation PNNL 20405:ASHRAE 90.1-2010 Wall... Construction CoA Roof Configuration PNNL 20405:ASHRAE 90.1-2010 Foundation Construction PNNL 20405:ASHRAE 90.1-2010 Wall Absorptance DOE 2.1E BDL SUMMARY, Page 12 Assuming gray, light oil paint Wall Insulation (hr-sq.ft.-°F/Btu) ASHRAE 90.1-2001 Table B-8...

  4. System architecture of offshore oil production systems

    E-Print Network [OSTI]

    Keller, James (James Thomas)

    2008-01-01

    This thesis presents an approach to applying Systems Architecture methods to the development of large, complex, commercial systems, particularly offshore oil and gas productions systems. The aim of this research was to ...

  5. Onsite Wastewater Treatment Systems: Spray Distribution System 

    E-Print Network [OSTI]

    Lesikar, Bruce J.

    2008-10-23

    Spray distribution systems for wastewater are much like lawn sprinkler systems, in that they spray treated wastewater over the surface of a yard. This publication explains how spray distribution systems work, what their design requirements are...

  6. Examining Survivability of Systems of Systems

    E-Print Network [OSTI]

    Mekdeci, Brian

    Previous research has identified design principles that enable survivability for systems, but it is unclear if these principles are appropriate and sufficient for systems of systems as well. This paper presents a preliminary ...

  7. Hybrid solar thermal-photovoltaic systems demonstration, Phase I and II. Final technical progress report, July 5, 1979-December 1982

    SciTech Connect (OSTI)

    Loferski, J.J.

    1983-12-01

    The purpose of the project is to investigate a system based on combined photovoltaic/thermal (PV/T) panels to supply the energy needs of a small single family residence. The system finally selected and constructed uses PV/T panels which utilize air as the heat transfer medium. Optimization of thermal performance was accomplished by attaching metal fins to the back surface of each cell which significantly increased the heat transfer coefficient from the solar cells to the air stream. The other major components of the selected system are an air-to-air heat pump, a rock bin thermal energy storage bin, a synchronous dc-to-ac converter, a microprocessor to control the system, a heat exchanger for the domestic hot water system and of course the building itself which is a one story, well insulated structure having a floor area of 1200 ft/sup 2/. A prototype collector was constructed and tested. Based on this experience, twenty collectors, containing 2860 four inch diameter solar cells, were constructed and installed on the building. Performance of the system was simulated using a TRNSYS-derived program, modified to accommodate PV/T panels and to include the particular components included in the selected system. Simulation of the performance showed that about 65 percent of the total annual energy needs of the building would be provided by the PV/T system. Of this total, about one half is produced at a time when it can be used in the building and one half must be sold back to the utility.

  8. Separation system

    DOE Patents [OSTI]

    Rubin, Leslie S. (Newton, MA)

    1986-01-01

    A separation system for dewatering radioactive waste materials includes a disposal container, drive structure for receiving the container, and means for releasably attaching the container to the drive structure. Separation structure disposed in the container adjacent the inner surface of the side wall structure retains solids while allowing passage of liquids. Inlet port structure in the container top wall is normally closed by first valve structure that is centrifugally actuated to open the inlet port and discharge port structure at the container periphery receives liquid that passes through the separation structure and is normally closed by second valve structure that is centrifugally actuated to open the discharge ports. The container also includes coupling structure for releasable engagement with the centrifugal drive structure. Centrifugal force produced when the container is driven in rotation by the drive structure opens the valve structures, and radioactive waste material introduced into the container through the open inlet port is dewatered, and the waste is compacted. The ports are automatically closed by the valves when the container drum is not subjected to centrifugal force such that containment effectiveness is enhanced and exposure of personnel to radioactive materials is minimized.

  9. A VIRTUAL OPERATING SYSTEM

    E-Print Network [OSTI]

    Hall, Dennis E.

    2013-01-01

    Unix time-sharing operating system. D. Hall, D. Scherrer, J.Prentice~Hall, Hansen, "Operating System Principles", Inc. ,of California. A Virtual Operating System Dennis E. Hall

  10. Solar powered desalination system

    E-Print Network [OSTI]

    Mateo, Tiffany Alisa

    2011-01-01

    done using photovoltaic systems or by a photoelectrochemicalprocess. Of course, photovoltaic systems convert sunlightwill be powered by the photovoltaic system. Also, a typical

  11. Sandia Energy - Monitoring Systems

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Monitoring Systems Home Climate & Earth Systems Climate Measurement & Modeling Arctic Climate Measurements Monitoring Systems Monitoring Systemscwdd2015-06-02T22:40:49+00:00...

  12. Environmental Management System

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Management System Environmental Management System An Environmental Management System is a systematic method for assessing mission activities, determining the environmental impacts...

  13. Franklin File Systems

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Files systems Files systems NERSC's global home and project file systems are available on Franklin. Additionally, Franklin has over 400 TB of locally attached high-performance...

  14. MERIT Hg System Review V.B. Graves

    E-Print Network [OSTI]

    McDonald, Kirk

    in rough vacuum · Full-beam interaction length is 30-cm · Beam line is 120cm above the tunnel floor · Up between the Hg and the tunnel environment · Hydraulic pump will be in adjacent tunnel, personnel in remote/vapor containment - Ports for instruments, Hg fill/drain, hydraulics · Optical diagnostic components - Passive

  15. Heating System Specification Specification of Heating System

    E-Print Network [OSTI]

    Day, Nancy

    Appendix A Heating System Specification /* Specification of Heating System (loosely based */ requestHeat : Room ­? bool; 306 #12; APPENDIX A. HEATING SYSTEM SPECIFICATION 307 /* user inputs */ living --- HEATERâ??ACTIVE --- ACTIVATINGâ??HEATER --- HEATERâ??RUNNING ; #12; APPENDIX A. HEATING SYSTEM SPECIFICATION

  16. Complex System Classification

    E-Print Network [OSTI]

    Magee, Christopher

    2004-07-24

    The use of terms such as “Engineering Systems”, “System of systems” and others have been coming into greater use over the past decade to denote systems of importance but with implied higher complexity than for the term ...

  17. Industrial and Systems engineering

    E-Print Network [OSTI]

    Berdichevsky, Victor

    Industrial and Systems engineering COLLEGE of ENGINEERING DepartmentofIndustrialandSystemsEngineering EDGE Engineering Entrepreneur Certificate Program is a great addition to an industrial and systems to expert clinical recommendations. engineering.wayne.edu/isefaculty Industrial and systems engineering

  18. Expert systems in transportation

    SciTech Connect (OSTI)

    O'Leary, K.P.

    1988-01-01

    The 5 papers in the report deal with the following areas: Knowledge representation and software selection for expert-systems design; Expert-system architecture for retaining-wall design; Development of expert-systems technology in the California Department of Transportation; Development of an expert system to assist in the interactive graphic transit system design process; Expert systems development for contingency transportation planing.

  19. A BIM-based system for demolition and renovation waste estimation and planning

    SciTech Connect (OSTI)

    Cheng, Jack C.P., E-mail: cejcheng@ust.hk [Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology (Hong Kong); Ma, Lauren Y.H., E-mail: yingzi@ust.hk [Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology (Hong Kong)

    2013-06-15

    Highlights: ? We developed a waste estimation system leveraging the BIM technology. ? The system can calculate waste disposal charging fee and pick-up truck demand. ? We presented an example scenario demonstrating this system. ? Automatic, time-saving and wide applicability are the features of the system. - Abstract: Due to the rising worldwide awareness of green environment, both government and contractors have to consider effective construction and demolition (C and D) waste management practices. The last two decades have witnessed the growing importance of demolition and renovation (D and R) works and the growing amount of D and R waste disposed to landfills every day, especially in developed cities like Hong Kong. Quantitative waste prediction is crucial for waste management. It can enable contractors to pinpoint critical waste generation processes and to plan waste control strategies. In addition, waste estimation could also facilitate some government waste management policies, such as the waste disposal charging scheme in Hong Kong. Currently, tools that can accurately and conveniently estimate the amount of waste from construction, renovation, and demolition projects are lacking. In the light of this research gap, this paper presents a building information modeling (BIM) based system that we have developed for estimation and planning of D and R waste. BIM allows multi-disciplinary information to be superimposed within one digital building model. Our system can extract material and volume information through the BIM model and integrate the information for detailed waste estimation and planning. Waste recycling and reuse are also considered in our system. Extracted material information can be provided to recyclers before demolition or renovation to make recycling stage more cooperative and more efficient. Pick-up truck requirements and waste disposal charging fee for different waste facilities will also be predicted through our system. The results could provide alerts to contractors ahead of time at project planning stage. This paper also presents an example scenario with a 47-floor residential building in Hong Kong to demonstrate our D and R waste estimation and planning system. As the BIM technology has been increasingly adopted in the architectural, engineering and construction industry and digital building information models will likely to be available for most buildings (including historical buildings) in the future, our system can be used in various demolition and renovation projects and be extended to facilitate project control.

  20. Duty-Cycling Buildings Aggressively: The Next Frontier in HVAC Control

    E-Print Network [OSTI]

    Simunic, Tajana

    network across an entire floor of a university building and our data shows several periods of low energy savings of 7.59% to 12.85% for the HVAC system by controlling just one floor of our four floor- sumers can be lighting, computing infrastructure, or what is most often the case, heating ventilation