Combined Operation of Solar Energy Source Heat Pump, Low-vale Electricity and Floor Radiant System  

E-Print Network (OSTI)

solar energy, low-vale electricity as heat sources in a floor radiant system are analyzed. This paper presents a new heat pump system and discusses its operational modes in winter....

Liu, G.; Guo, Z.; Hu, S.

2006-01-01T23:59:59.000Z

2

Experimental Study of the Floor Radiant Cooling System Combined with Displacement Ventilation  

E-Print Network (OSTI)

ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency, Vol. IV-11-4 Experimental Study of the Floor Radiant Cooling System Combined with Displacement Ventilation Yanli Ren1, Deying Li2, Yufeng Zhang1 1...

Ren, Y.; Li, D.; Zhang, Y.

2006-01-01T23:59:59.000Z

3

Numerical Simulation of Thermal Performance of Floor Radiant Heating System with Enclosed Phase Change Material  

E-Print Network (OSTI)

of the energy storage floor is designed,which places heat pipes in the enclosed phase change material (PCM) layer, without concrete in it. The PCM thermal storage time is studied in relation to the floor surface temperature under different low-temperature hot...

Qiu, L.; Wu, X.

2006-01-01T23:59:59.000Z

4

Hydronic Radiant Cooling Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

4 4 Hydronic Radiant Cooling Systems Cooling nonresidential buildings in the U.S. contributes significantly to electrical power consumption and peak power demand. Part of the electrical energy used to cool buildings is drawn by fans transporting cool air through the ducts. The typical thermal cooling peak load component for California office buildings can be divided as follows: 31% for lighting, 13% for people, 14% for air transport, and 6% for equipment (in the graph below, these account for 62.5% of the electrical peak load, labeled "chiller"). Approximately 37% of the electrical peak power is required for air transport, and the remainder is necessary to operate the compressor. DOE-2 simulations for different California climates using the California

5

Radiant Heating Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiant Heating Basics Radiant Heating Basics Radiant Heating Basics August 19, 2013 - 10:33am Addthis Radiant heating systems involve supplying heat directly to the floor or to panels in the walls or ceiling of a house. The systems depend largely on radiant heat transfer: the delivery of heat directly from the hot surface to the people and objects in the room via the radiation of heat, which is also called infrared radiation. Radiant heating is the effect you feel when you can feel the warmth of a hot stovetop element from across the room. When radiant heating is located in the floor, it is often called radiant floor heating or simply floor heating. Despite the name, radiant floor heating systems also depend heavily on convection, the natural circulation of heat within a room, caused by heat rising from the floor. Radiant floor

6

Radiant Heating Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiant Heating Basics Radiant Heating Basics Radiant Heating Basics August 19, 2013 - 10:33am Addthis Radiant heating systems involve supplying heat directly to the floor or to panels in the walls or ceiling of a house. The systems depend largely on radiant heat transfer: the delivery of heat directly from the hot surface to the people and objects in the room via the radiation of heat, which is also called infrared radiation. Radiant heating is the effect you feel when you can feel the warmth of a hot stovetop element from across the room. When radiant heating is located in the floor, it is often called radiant floor heating or simply floor heating. Despite the name, radiant floor heating systems also depend heavily on convection, the natural circulation of heat within a room, caused by heat rising from the floor. Radiant floor

7

Radiant Heating | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiant Heating Radiant Heating Radiant Heating June 24, 2012 - 5:52pm Addthis In-wall radiant heating in a house under construction near Denver. | Photo courtesy of Warren Gretz, NREL. In-wall radiant heating in a house under construction near Denver. | Photo courtesy of Warren Gretz, NREL. Radiant heating systems supply heat directly to the floor or to panels in the wall or ceiling of a house. The systems depend largely on radiant heat transfer -- the delivery of heat directly from the hot surface to the people and objects in the room via infrared radiation. Radiant heating is the effect you feel when you can feel the warmth of a hot stovetop element from across the room. When radiant heating is located in the floor, it is often called radiant floor heating or simply floor heating.

8

Radiant Heating | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiant Heating Radiant Heating Radiant Heating June 24, 2012 - 5:52pm Addthis In-wall radiant heating in a house under construction near Denver. | Photo courtesy of Warren Gretz, NREL. In-wall radiant heating in a house under construction near Denver. | Photo courtesy of Warren Gretz, NREL. Radiant heating systems supply heat directly to the floor or to panels in the wall or ceiling of a house. The systems depend largely on radiant heat transfer -- the delivery of heat directly from the hot surface to the people and objects in the room via infrared radiation. Radiant heating is the effect you feel when you can feel the warmth of a hot stovetop element from across the room. When radiant heating is located in the floor, it is often called radiant floor heating or simply floor heating.

9

Topic 14. Retrofit and optimal operation of the building energy systems Performances of Low Temperature Radiant Heating Systems  

E-Print Network (OSTI)

panel system are given by its energy (the consumption of gas for heating, electricity for pumps Temperature Radiant Heating Systems Milorad Boji1*, Dragan Cvetkovi1 , Jasmina Skerli1 , Danijela Nikoli1, wall heating, floor heating, ceiling heating, EnergyPlus SUMMARY Low temperature heating panel systems

Paris-Sud XI, Université de

10

Design of a flooring removal system for asbestos backed flooring  

E-Print Network (OSTI)

DESIGN OF A FLOORING REMOVAL SYSTEM FOR ASBESTOS BACKED FLOORING A Thesis bi PATHANJALI SAI PUDURU Submitted to the Office of Graduate Studies of Texas AJsM University in partial fulfillment of the requirements for the degree of MASTER... OF SCIENCE May 1990 Major Subject: Mechanical Engineering DESIGN OF A FLOORING REIyIOVAL SYSTEUil F' OR ASBESTOS BACKED FLOORING A Thesis PATHAX. JALI SAI Pl DI. RF Approved as to style ansi r ontent bp David G. . ansson (C'barr of C'omrnittee) Alan...

Puduru, Pathanjali Sai

2012-06-07T23:59:59.000Z

11

Effect of a Radiant Panel Cooling System on Indoor Air Quality of a Conditioned Space  

E-Print Network (OSTI)

This paper discusses the effect of a radiant cooling panel system on an indoor air quality (IAQ) of a conditioned space. In this study, ceiling radiant cooling panel, mechanical ventilation with fan coil unit (FCU) and 100% fresh air are used...

Mohamed, E.; Abdalla, K. N.

2010-01-01T23:59:59.000Z

12

Energy, cost, and CO 2 emission comparison between radiant wall panel systems and radiator systems  

E-Print Network (OSTI)

The main goal of this paper is to evaluate the possibility of application or replacement of radiators with low-temperature radiant panels. This paper shows the comparison results of operations of 4 space heating systems: the low-temperature radiant panel system without any additional thermal insulation of external walls (PH-WOI), the low-temperature radiant panel system with additional thermal insulation of external walls (PH-WI), the radiator system without any additional thermal insulation of external walls (the classical heating system) (RH-WOI), and the radiator system with additional thermal insulation of external walls (RH-WI). The operation of each system is simulated by software EnergyPlus. The investigation shows that the PH-WI gives the best results. The RH-WOI has the largest energy consumption, and the largest pollutant emission. However, the PH-WI requires the highest investment.

Milorad Boji?; Dragan Cvetkovi?; Marko Mileti?; Jovan Maleševi?; Harry Boyer

2012-12-18T23:59:59.000Z

13

Energy, cost, and CO 2 emission comparison between radiant wall panel systems and radiator systems  

E-Print Network (OSTI)

The main goal of this paper is to evaluate the possibility of application or replacement of radiators with low-temperature radiant panels. This paper shows the comparison results of operations of 4 space heating systems: the low-temperature radiant panel system without any additional thermal insulation of external walls (PH-WOI), the low-temperature radiant panel system with additional thermal insulation of external walls (PH-WI), the radiator system without any additional thermal insulation of external walls (the classical heating system) (RH-WOI), and the radiator system with additional thermal insulation of external walls (RH-WI). The operation of each system is simulated by software EnergyPlus. The investigation shows that the PH-WI gives the best results. The RH-WOI has the largest energy consumption, and the largest pollutant emission. However, the PH-WI requires the highest investment.

Boji?, Milorad; Mileti?, Marko; Maleševi?, Jovan; Boyer, Harry

2012-01-01T23:59:59.000Z

14

An investigation of a residential solar system coupled to a radiant panel ceiling  

SciTech Connect

An experimental study of a solar-radiant heating system was performed at Iowa State University's Energy Research House (ERH). The ERH was constructed with copper tubes embedded in the plaster ceilings, thus providing a unique radiant heating system. In addition, 24 water-glycol, flat-plate solar collectors were mounted on the south side of the residence. The present study uses the solar collectors to heat a storage tank via a submerged copper tube oil. Hot water from the storage tank is then circulated through a heat exchanger, which heats the water flowing through the radiant ceiling. This paper contains a description of the solar-radiant system and an interpretation of the data that were measured during a series of transient experiments. In addition, the performance of the flat-plate solar collectors and the water storage tank were evaluated. The characteristics of a solar-to-radiant heat exchanger were also investigated. The thermal behavior of the radiant ceiling and the room enclosures were observed, and the heat transfer from the ceiling by radiation and convection was estimated. The overall heating system was also evaluated using the thermal performances of the individual components. The results of this study verify that it is feasible to use a solar system coupled to a low-temperature radiant-panel heating system for space heating. A sample performance evaluation is also presented.

Zhang, Z.; Pate, M.; Nelson, R.

1988-08-01T23:59:59.000Z

15

Analysis of Attic Radiant Barrier Systems Using Mathematical Models  

E-Print Network (OSTI)

Center, Cape Canaveral, FL, January 1988. 3. Vilkes, K.E. and D.V. Yarbrough, "Radiant Barrier Research Plan," Draft Report, ORNL/CON-256, Oak Ridge National Laboratory, Oak Ridge, TN, April 1988. 4. ASHRAE Aandbook of Fundamentals, American... Measurements of Single-Family Houses with Attics Containing Radiant Barriers," Final Report, ORNL/CON-200, Oak Ridge National Laboratory, Oak Ridge, TN, July 1986. 8. Cummings, J. B., "Central Air Condi tioner Impact Upon Infiltration Rates in Florida...

Fairey, P.; Swami, M.

1988-01-01T23:59:59.000Z

16

Event-based Green Scheduling of Radiant Systems in Buildings Truong X. Nghiem, George J. Pappas and Rahul Mangharam  

E-Print Network (OSTI)

of electric radiant heating systems while maintaining indoor thermal comfort. This paper develops an event and Rahul Mangharam Department of Electrical and Systems Engineering University of Pennsylvania {nghiem of a multi-zone hydronic radiant system can cause temporally correlated electricity demand surges when

Pappas, George J.

17

Mechanical decontamination techniques for floor drain systems  

SciTech Connect

The unprecedented nature of cleanup activities at Three Mile Island Unit 2 (TMI-2) following the 1979 accident has necessitated the development of new techniques to deal with radiation and contamination in the plant. One of these problems was decontamination of floor drain systems, which had become highly contaminated with various forms of dirt and sludge containing high levels of fission products and fuel from the damaged reactor core. The bulk of this contamination is loosely adherent to the drain pipe walls; however, significant amounts of contamination have become incorporated into pipe wall oxide and corrosion layers and embedded in microscopic pits and fissures in the pipe wall material. The need to remove this contamination was recognized early in the TMI-2 cleanup effort. A program consisting of development and laboratory testing of floor drain decontamination techniques was undertaken early in the cleanup with support from the Electric Power Research Institute (EPRI). Based on this initial research, two techniques were judged to show promise for use at TMI-2: a rotating brush hone system and a high-pressure water mole nozzle system. Actual use of these devices to clean floor drains at TMI-2 has yielded mixed decontamination results. The decontamination effectiveness that has been obtained is highly dependent on the nature of the contamination in the drain pipe and the combination of decontamination techniques used.

Palau, G.L.; Saigusa, Moriyuki

1987-01-01T23:59:59.000Z

18

Thermophotovoltaic power generation systems using natural gas-fired radiant burners  

Science Journals Connector (OSTI)

Thermophotovoltaic (TPV) power generation in gas-fired furnaces is attracting technical attention. Considerable work has been done in the area of low bandgap GaSb cell-based TPV systems as well as silicon solar cell-based TPV systems. Previous investigations have shown that a radiant burner with a high conversion level of fuel to radiation energy must be developed to realize an efficient TPV system. In our work, we investigated different natural gas-fired radiant burners in order to raise the conversion of fuel energy to thermal radiation. These burners were used as radiation sources to establish and test two TPV prototype systems. It was found that for a non-surface combustion radiant burner, the radiation output can be enhanced using a thermal radiator with a porous structure. Also, we developed a cascaded radiant burner that generates two streams of radiation output. One stream illuminates silicon concentrator solar cells while the other drives low bandgap GaSb cells. In this way, useful radiation output and thus TPV system efficiency are significantly increased due to the cascaded utilization of combustion heat and optimized thermal management.

K. Qiu; A.C.S. Hayden

2007-01-01T23:59:59.000Z

19

CFD Simulation and Analysis of the Combined Evaporative Cooling and Radiant Ceiling Air-conditioning System  

E-Print Network (OSTI)

, and the ceiling cooling system deals with the other part of sensible loads in the air-conditioned zone, so that the condensation on radiant panels and the insufficiency of cooling capacity can be avoided. The cooling water at 18? used in the cooling coils...

Xiang, H.; Yinming, L.; Junmei, W.

2006-01-01T23:59:59.000Z

20

A Novel Integrated TPV Power Generation System Based on a Cascaded Radiant Burner  

Science Journals Connector (OSTI)

A cascaded radiant burner has been developed and based on this burner a novel integrated TPV system has been built. In this system low bandgap GaSb cells and silicon concentrator solar cells are employed integratedly. The unique cascaded radiant burner consists of two different radiators which cascade?emit two streams of radiation with different spectra. The two different radiators are arranged in tandem with their surface temperatures being different as well. Two streams of radiation output are matched respectively to the bandgaps of silicon cells and GaSb cells. Thus one stream of radiation output illuminates silicon concentrator solar cells while the other drives low bandgap GaSb cells in the integrated system. In this work the combustion performance of the cascaded radiant burner was investigated at varying degrees of exhaust heat recuperation. The electrical output characteristics of both silicon concentrator solar cells and GaSb cells in the gas combustion?driven TPV system were measured under various operating conditions. It is shown that this innovative design considerably increases the TPV system efficiency due to the cascaded utilization of heat released during natural gas combustion and the optimized thermal management.

K. Qiu; A. C. S. Hayden

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Behavior of Bidirectional Spring Unit in Isolated Floor Systems  

E-Print Network (OSTI)

gravity based sys- tems suspension mechanisms or linear spring based systems coil springs or rubber unitsBehavior of Bidirectional Spring Unit in Isolated Floor Systems Shenlei Cui, M.ASCE1 ; Michel of bidirectional spring units used as isolators in a kind of isolated floor system, three types of characterization

Bruneau, Michel

22

Study of the Heating Load of a Manufactured Space with a Gas-fired Radiant Heating System  

E-Print Network (OSTI)

A thermal balance mathematics model of a manufactured space with a gas-fired radiant heating system is established to calculate the heating load. Computer programs are used to solve the model. Envelope internal surface temperatures under different...

Zheng, X.; Dong, Z.

2006-01-01T23:59:59.000Z

23

Clouds and the Earth''s Radiant Energy System (CERES) Algorithm Theoretical Basis Document. Volume I-Overviews (Subsystem 0)  

Science Journals Connector (OSTI)

The theoretical bases for the Release 1 algorithms that will be used to process satellite data for investigation of the Clouds and the Earth''s Radiant Energy System (CERES) are described. The architecture for software implementation of the methodologies ...

Team CERES Science

1995-12-01T23:59:59.000Z

24

TPV Power Generation System Using a High Temperature Metal Radiant Burner  

Science Journals Connector (OSTI)

Interest has grown in micro?combined heat and power (micro?CHP). Thermophotovoltaic (TPV) generation of electricity in fuel?fired furnaces is one of the micro?CHP technologies that are attracting technical attention. Previous investigations have shown that a radiant burner that can efficiently convert fuel chemical energy into radiation energy is crucial to realize a practical TPV power system. In this work we developed a TPV power generation system using a gas?fired metal radiant burner. The burner consists of a high temperature alloy emitter which could have an increased emissivity at short wavelengths and low emissivity at long wavelengths. The metal emitter is capable of bearing high temperatures of interest to fuel?fired TPV power conversion. GaSb TPV cells were tested in the combustion?driven radiant source. Electric output characteristics of the TPV cells were investigated at various operating conditions. The electric power output of the TPV cells was demonstrated to be promising. At an emitter temperature of 1185°C an electric power density of 0.476 W/cm2 was generated by the GaSb cells. It is shown that the metal emitter is attractive and could be applied to practical fuel?fired TPV power systems.

K. Qiu; A. C. S. Hayden; E. Entchev

2007-01-01T23:59:59.000Z

25

Technical evaluation of a solar heating system having conventional hydronic solar collectors and a radiant panel slab. Final report  

SciTech Connect

A simple innovative solar heating design (Solar Option One) using conventional hydronic solar collectors and a radiant panel slab was constructed. An objective of hybrid solar design is to combine the relative advantages of active and passive design approaches while minimizing their respective disadvantages. A test house using the Solar Option One heating system was experimentally monitored to determine its energy based performance during the 1982-83 heating season. The test residence is located in Lyndonville, Vermont, an area which has a characteristically cold and cloudy climate. The two story residence has a floor area of about 1400 square feet and is constructed on a 720 square foot 5.5 inch thick floor slab. A 24 inch packed gravel bed is located beneath the slab and the slab-gravel bed is insulated by two inches of polystyrene insulation. The test building is of frame construction and uses insulation levels which have become commonplace throughout the country. The structure would not fall into the superinsulated category but was tightly constructed so as to have a low infiltration level. The building is sun-tempered in that windows were concentrated somewhat on the South side and all but avoided on the North. A solar greenhouse on the South side of the building was closed off from the structure permanently throughout the testing so as to better observe the solar heating invention without confounding variables. The monitoring equipment generated an internal gain of about 17,000 BTUs per day, roughly the equivalent of occupancy by two persons. A full description of the experimental testing program is given. System efficiency and performance are reported.

Starr, R.J.

1984-04-01T23:59:59.000Z

26

Radiant Cooling | Department of Energy  

Energy Savers (EERE)

hours, reducing the electrical demand on electric utilities. Learn More Home Cooling Systems References Final Report Compilation for Residential Hydronic Radiant Cooling and...

27

Production system improvement : floor area reduction and cycle time analysis  

E-Print Network (OSTI)

A medical device company challenged a research team to reduce the manufacturing floor space required for an occlusion system product by one third. The team first cataloged equipment location and size, detailed the processes ...

Peterson, Jennifer J. (Jennifer Jeanne)

2012-01-01T23:59:59.000Z

28

Energy Saving in Office Building by Floor Integration System: Reducing  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Saving in Office Building by Floor Integration System: Reducing Energy Saving in Office Building by Floor Integration System: Reducing Total Energy of HVAC and Lighting system using daylight Speaker(s): Yoshifumi Murakami Date: May 20, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Naoya Motegi Information Technology that is featured by standard communication protocol like Lon Works, BACnet is very useful for managing building systems. Now we can collect much data quickly and easily and to analyze them in detail with this technology. Under the circumstances in that saving energy and reducing CO2 are required strongly, important thing is finding the effective information for building operation and control from collected data and the analysis of them. In our project, the floor integration controller that integrates the each building systems was proposed. It

29

Modeling of Residential Attics with Radiant Barriers  

E-Print Network (OSTI)

This paper gives a summary of the efforts at ORNL in modeling residential attics with radiant barriers. Analytical models based on a system of macroscopic heat balances have been developed. Separate models have been developed for horizontal radiant...

Wilkes, K. E.

1988-01-01T23:59:59.000Z

30

Thermal simulation and system optimization of a chilled ceiling coupled with a floor containing a phase change material (PCM)  

Science Journals Connector (OSTI)

Abstract The integration of phase change materials (PCMs) for cooling applications in buildings reduces the amplitude of indoor air temperature fluctuations due to solar and internal gains, enabling passive solar, HVAC system downsizing or off-peak cooling designs. This work studies the use of radiant systems for discharging heat stored in a PCM; this approach differs from the typical practice of accomplishing this task by either night cooling ventilation or embedding an active heat exchanger into the PCM of the wall. In this study, a PCM is incorporated into the floor, and a hydronic radiant ceiling system is used as the energy discharge system. The advantages and disadvantages of this configuration in terms of cooling energy demands and thermal comforts of occupants are analyzed using the simulation software TRNSYS®. Five design parameters are optimized using the software GENOPT®. The simulation reveals that when accompanied by an air-to-air heat recovery system, this configuration can significantly reduce the cooling energy demand (more than 50% compared to the cooling energy demand of the same building without PCM) and can thus significantly reduce the energy consumption. However, the degrees of occupant comfort will inevitably vary (i.e., the predicted percent dissatisfied (PPD) increases by 2–5%).

J.F. Belmonte; P. Eguía; A.E. Molina; J.A. Almendros-Ibáñez

2015-01-01T23:59:59.000Z

31

Visopt ShopFloor System: Integrating Planning into Production Scheduling  

E-Print Network (OSTI)

Visopt ShopFloor System: Integrating Planning into Production Scheduling Roman Barták Charles, the first machine pre-processes the item (3 time units) that is finished in the second machine (additional 3 in parallel and a worker is required (left) or via a serial production when the item is pre- processed

Bartak, Roman

32

Terminology Radiant Energy (J)  

E-Print Network (OSTI)

Terminology Radiant Energy (J) Add time Radiant Flux (J/s) add area Hemispherical Directional add, temperature, wavelength, look angle. The temperature of the black body which radiates the same radiant energy]2)=1.389 kW/m2 #12;#12;The amount of radiant energy onto, off of, or through a surface per unit time

Herrick, Robert R.

33

Influence of Attic Radiant Barrier Systems on Air Conditioning Demand in an Utility Pilot Project  

E-Print Network (OSTI)

by Oak Ridge National Laboratory showed space heating reductions in Miami, Orlando and Atlanta (Wilkes, 1991). Also, detailed measurements by ORNL showed heating demand and energy reductions in monitored Tennessee homes (Levins and Karnitz, 1987...- 11 and R-30 Insulation, ORNL/CON-226, Oak Ridge National Laboratories, Oak Ridge, TN. Levins, W. P. and Karnitz, M. A. and Hall, J.A., 1990. Cooling Season Energy Measurements of Dust and Ventilation Effects on Radiant Barriers, ORNL/CON-271...

Parker, D. S.; Sherwin, J. R.

2002-01-01T23:59:59.000Z

34

EXPERIMENTAL STUDY OF BI-DIRECTIONAL SPRING UNIT IN ISOLATED FLOOR SYSTEMS  

E-Print Network (OSTI)

) or linear spring based systems (coil springs or rubber units used for restoration force), with viscousEXPERIMENTAL STUDY OF BI-DIRECTIONAL SPRING UNIT IN ISOLATED FLOOR SYSTEMS Shenlei Cui1 , Michel the mechanical behavior of bi-directional spring units used as isolators in a kind of such isolated floor systems

Bruneau, Michel

35

Radiant Solar | Open Energy Information  

Open Energy Info (EERE)

Radiant Solar Radiant Solar Jump to: navigation, search Name Radiant Solar Place Secunderabad, Andhra Pradesh, India Zip 500009 Sector Solar Product Solar products company focused on lanterns, lighting systems and water heaters. Coordinates 17.46071°, 78.49298° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":17.46071,"lon":78.49298,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

36

Validation of Geolocation of Measurements of the Clouds and the Earth’s Radiant Energy System (CERES) Scanning Radiometers aboard Three Spacecraft  

Science Journals Connector (OSTI)

The Clouds and the Earth’s Radiant Energy System (CERES) instrument is a scanning radiometer for measuring Earth-emitted and -reflected solar radiation to understand Earth’s energy balance. One CERES instrument was placed into orbit aboard the ...

G. Louis Smith; Kory J. Priestley; Phillip C. Hess; Chris Currey; Peter Spence

2009-11-01T23:59:59.000Z

37

Preliminary Study of a Vented Attic Radiant Barrier System in Hot, Humid Climates Using Side-by-Side, Full-Scale Test Houses  

E-Print Network (OSTI)

A series of side-by-side tests was performed using two full scale test houses to determine the effectiveness of a Vented Radiant Barrier System (VRBS) in reducing the ceiling heat flux during the summer cooling season in North Florida. Another...

Lear, W. E.; Barrup, T. E.; Davis, K. E.

1987-01-01T23:59:59.000Z

38

An experimental study of the transient response of a radiant panel ceiling and enclosure  

SciTech Connect

The transient responses of a radiant heating system and enclosure was investigated for a range of hot-water supply temperatures and flow rates. The radiant heating system consisted of copper tubes embedded in a standard plaster ceiling at 6-in (152-mm) intervals. Transient experiments were performed by heating the radiant ceiling and enclosure from a cooled-down condition by using a step change in the hot-water supply temperature. Temperature transients in the water supply and return lines on the ceiling and wall surfaces and in the room air were then monitored for a period of several hours. Results were as follows: the ceiling temperature was uniform; the thermal response of the ceiling and enclosure was slow because of the large thermal mass in the ceiling; the air temperature did not lag the wall and floor temperature; and the room walls were heated by a combination of radiation heat transfer from the ceiling and convection heat transfer from the air. In addition, the transient response of the radiant system was found to be a function of water supply temperature but not of water flow rate.

Zhang, Z.; Pate, M.B.

1986-01-01T23:59:59.000Z

39

Thermal performance of phase change material energy storage floor for active solar water-heating system  

Science Journals Connector (OSTI)

The conventional active solar water-heating floor system contains a big water tank to store energy in the day time for heating at night, which takes much building space and is very heavy. In order to reduce the w...

Ruolang Zeng; Xin Wang; Wei Xiao…

2010-06-01T23:59:59.000Z

40

Production system improvement at a medical devices company : floor layout reduction and manpower analysis  

E-Print Network (OSTI)

Due to the low demand and the need to introduce other production lines in the floor, the medical devices company wants to optimize the utilization of space and manpower for the occlusion system product. This thesis shows ...

AlEisa, Abdulaziz A. (Abdulaziz Asaad)

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Development of an NC equipment level controller in a hierarchical shop floor control system  

E-Print Network (OSTI)

The methodology of developing an NC equipment controller in a Computer Integrated Manufacturing (CIM) System, which is based on a philosophy of hierarchical shop floor control, is presented in this research. The underlying architecture consists...

Chang, William

2012-06-07T23:59:59.000Z

42

Radiant Apparatus | Open Energy Information  

Open Energy Info (EERE)

Apparatus Apparatus Jump to: navigation, search Name Radiant Apparatus Place Fairfax, Virginia Zip 22038-3333 Sector Solar Product Radiant Apparatus develops multi-functional, portable solar energy-harnessing systems, as well as potable water systems and emergency shelters. Coordinates 38.841574°, -77.308132° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.841574,"lon":-77.308132,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

43

Radiant Barriers | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radiant Barriers Radiant Barriers Radiant Barriers May 30, 2012 - 2:07pm Addthis What does this mean for me? Properly installed radiant barriers can reduce your cooling costs. Radiant barriers are easiest to install in new construction, but can be installed in your existing house, especially if it has an open attic. How does it work? Radiant barriers work by reflecting radiant heat away from living spaces. Radiant barriers are installed in homes -- usually in attics -- primarily to reduce summer heat gain and reduce cooling costs. The barriers consist of a highly reflective material that reflects radiant heat rather than absorbing it. They don't, however, reduce heat conduction like thermal insulation materials. How They Work Heat travels from a warm area to a cool area by a combination of

44

Wing Wave: Feasible, Alternative, Renewable, Electrical Energy Producing Ocean Floor System  

E-Print Network (OSTI)

Wing Wave: Feasible, Alternative, Renewable, Electrical Energy Producing Ocean Floor System Mark, alternative energy system to convert the circular motion of ocean waves as they propagate through the sea and feasible alternative, renewable, electrical energy producing subsea system. Index Terms--ocean energy, wave

Wood, Stephen L.

45

Terminology Radiant Energy (J)  

E-Print Network (OSTI)

Terminology Radiant Energy (J) Add time Radiant Flux (J/s) add area Hemispherical Directional add wavelengthadd wavelength Most sensors yield these values I M L L E #12;r dA0 dA1 Source Receiver d0 = dA1cos1 r = d2·r2 dA0cos0 dA1cos1 #12;r dA0 dA1 dA1cos1 Source Receiver L1L0 1 d1 = dA0cos0 r2 L = d2 d

Herrick, Robert R.

46

Heat pumps and under floor heating as a heating system for Finnish low-rise residential buildings.  

E-Print Network (OSTI)

??In bachelor’s thesis the study of under floor heating system with ground source heat pump for the heat transfers fluid heating is considered. The case… (more)

Chuduk, Svetlana

2010-01-01T23:59:59.000Z

47

Indoor Humidity Analysis of an Integrated Radiant Cooling and Desiccant Ventilation System  

E-Print Network (OSTI)

, the diameter and depth of the wheel, face flow velocity, rotational speed and other operating conditions. Bulk et al. [11] proposed NTU correlations for design calculation of latent and total effectiveness of enthalpy wheels coated with silica gel..., Wr Te1,We1 Space Fig.2. Passive desiccant system Enthalpy wheels normally use an aluminum substrate coated with a molecular sieve material or silica gel. The effectiveness of an enthalpy wheel depends on the load of desiccant materials...

Gong, X.; Claridge, D. E.

2006-01-01T23:59:59.000Z

48

A Portable Real Time Data Acquisition System for the Comparison of Floor Vibration Data with AISC Design Guide  

E-Print Network (OSTI)

A portable real time vibration measurement data acquisition system was assembled with the intentionA Portable Real Time Data Acquisition System for the Comparison of Floor Vibration Data with AISC. THEORETICAL BACKGROUND In response to the increasing incidence of vibration problems in modern floor systems

Hines, Eric

49

Radiant Barriers | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Barriers Barriers Radiant Barriers May 30, 2012 - 2:07pm Addthis What does this mean for me? Properly installed radiant barriers can reduce your cooling costs. Radiant barriers are easiest to install in new construction, but can be installed in your existing house, especially if it has an open attic. How does it work? Radiant barriers work by reflecting radiant heat away from living spaces. Radiant barriers are installed in homes -- usually in attics -- primarily to reduce summer heat gain and reduce cooling costs. The barriers consist of a highly reflective material that reflects radiant heat rather than absorbing it. They don't, however, reduce heat conduction like thermal insulation materials. How They Work Heat travels from a warm area to a cool area by a combination of

50

Production system improvement : floor area reduction and inventory optimization  

E-Print Network (OSTI)

This thesis shows improvements of a medical device production system. The demand at the Medical Device Manufacturing Company (MDMC¹) is low for the occlusion system product and there is a need to introduce other production ...

Yang, Tianying, M. Eng. Massachusetts Institute of Technology

2012-01-01T23:59:59.000Z

51

Compression of felt?type thermal insulation layer for underfloor heating system and floor impact sound  

Science Journals Connector (OSTI)

In Korea almost every house uses underfloor heating which has advantages of thermal comfort and energy efficiency. However when it is constructed for high?rise apartment houses it yields a problem in floor impact sound insulation. It accounts for the fact that a foam?type thermal insulator sandwiched between structural slab and heating floor functions as a spring and easily transmits impacts on the floor to the slab. In that case the system's transmissibility is determined by dynamic stiffness of the thermal insulation layer and the lower the dynamic stiffness is the more the floor impact is isolated. For that reason apartments construction companies are attempting to lower the dynamic stiffness of the thermal insulation layer for impact sound reduction. As part of the attempt felt?type materials with relatively low dynamic stiffness such as glass wool or polyester felt are considered as a substitution for the foam?type thermal insulator. However there is a possibility that compression of the felt?type materials would increase the dynamic stiffness and the impact sound insulation effect at early stage might be weakened in the long term. This paper investigates the correlation between gradual compression of the felt?type thermal insulation layer and the impact sound variation.

Tongjun Cho; Hyun?Min Kim

2008-01-01T23:59:59.000Z

52

Floor System Vibration Control E.M. Hines, Ph.D., P.E., Res. Asst. Professor, Tufts University, Dept. Civ. & Env. Eng.;  

E-Print Network (OSTI)

Floor System Vibration Control E.M. Hines, Ph.D., P.E., Res. Asst. Professor, Tufts University in the design of steel and concrete floor systems to control vibrations suggests that a floor system's vibration-term collaborative research program between Tufts University and LeMessurier Consultants to investigate the vibration

Hines, Eric

53

Radiant energy collector. [Patent application  

DOE Patents (OSTI)

A cylindrical radiant energy collector is provided which includes a reflector spaced apart from an energy absorber. The reflector is of a particular shape which ideally eliminates gap losses.

McIntire, W.R.

1980-02-14T23:59:59.000Z

54

Radiant cooling research scoping study  

E-Print Network (OSTI)

ventilation air, fan-coil units, and added lightweightventilation air, fan-coil units, induction units, chilled-conditioned using a fan-coil unit or other non-radiant

Moore, Timothy; Bauman, Fred; Huizenga, Charlie

2006-01-01T23:59:59.000Z

55

Performance Testing of Radiant Barriers  

E-Print Network (OSTI)

PERFORMANCE TESTING OF RADIANT BARRIERS JAMES A. HALL TENNESSEE VALLEY AUTHORITY Chattanooga, Tennessee ABSTRACT TVA has conducted a study to determine the effects of radiant barriers (RBI (i.e., a mterial with a low emissivity surface facing...Conservation of Radiative Heat Transfer Tnrough Fibrous Insulation." University of Mississippi, Sponsored by Tennessee Valley Authority, Contract TV-641 l5A, December 1985. 3. Davies, &en L., I1Tne Design and Analysis of Industrial Experiments, Hafher Publishing...

Hall, J. A.

1986-01-01T23:59:59.000Z

56

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

SciTech Connect

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

Carpenter, S.C.; Kokko, J.P. [Enermodal Engineering Ltd., Kitchener, Ontario (Canada)

1998-12-31T23:59:59.000Z

57

Impact of the Position of a Radiator to Energy Consumption and Thermal Comfort in a Mixed Radiant and Convective Heating System  

E-Print Network (OSTI)

radiant temperature (MRT) determines the radiation heat exchange between the human body and surrounding surfaces. In a typical room, the air temperature and MRT are the only two variables the design engineer may control (Palmer and Chapman [14... Speed V r <40 fpm (<0.2 m/s) 40 to 120 fpm (0.2 to 0.6 m/s) 120 to 200 fpm (0.6 to 1.0 m/s) A 0.5 0.6 0.7 When air speed is small (less than 0.2m/s) or the difference between mean radiant and air temperature is small (less than 4 o C...

Gong, X.; Claridge, D. E.

2005-01-01T23:59:59.000Z

58

Radiant Energy | Open Energy Information  

Open Energy Info (EERE)

Energy Energy Jump to: navigation, search Name Radiant Energy Place Pleasanton, California Zip 94566 Sector Geothermal energy, Hydro, Solar Product Radiant is an independent energy producer which develops and owns solar, geothermal, and hydroelectric generating assets. Coordinates 28.967394°, -98.478862° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":28.967394,"lon":-98.478862,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

59

Online map of buildings using radiant technologies  

E-Print Network (OSTI)

data in science, technology and innovation. TechnologicalTopic D1: Smart and mobile technologies ONLINE MAP OFBUILDINGS USING RADIANT TECHNOLOGIES Caroline KARMANN 1,* ,

Karmann, Caroline; Schiavon, Stefano; Bauman, Fred

2014-01-01T23:59:59.000Z

60

Online map of buildings using radiant technologies  

E-Print Network (OSTI)

of radiant slab cooling using building simulation and fieldmeasurements. Energy and Buildings, 41, 3, 320-330.2013) Net-Zero Energy Buildings - Worldwide. Available at:

Karmann, Caroline; Schiavon, Stefano; Bauman, Fred

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Radiant cooling in US office buildings: Towards eliminating the perception of climate-imposed barriers  

SciTech Connect

Much attention is being given to improving the efficiency of air-conditioning systems through the promotion of more efficient cooling technologies. One such alternative, radiant cooling, is the subject of this thesis. Performance information from Western European buildings equipped with radiant cooling systems indicates that these systems not only reduce the building energy consumption but also provide additional economic and comfort-related benefits. Their potential in other markets such as the US has been largely overlooked due to lack of practical demonstration, and to the absence of simulation tools capable of predicting system performance in different climates. This thesis describes the development of RADCOOL, a simulation tool that models thermal and moisture-related effects in spaces equipped with radiant cooling systems. The thesis then conducts the first in-depth investigation of the climate-related aspects of the performance of radiant cooling systems in office buildings. The results of the investigation show that a building equipped with a radiant cooling system can be operated in any US climate with small risk of condensation. For the office space examined in the thesis, employing a radiant cooling system instead of a traditional all-air system can save on average 30% of the energy consumption and 27% of the peak power demand due to space conditioning. The savings potential is climate-dependent, and is larger in retrofitted buildings than in new construction. This thesis demonstrates the high performance potential of radiant cooling systems across a broad range of US climates. It further discusses the economics governing the US air-conditioning market and identifies the type of policy interventions and other measures that could encourage the adoption of radiant cooling in this market.

Stetiu, C.

1998-01-01T23:59:59.000Z

62

Base load fuel comsumption with radiant boiler simulation  

SciTech Connect

The operating point of an oil fired radiant boiler, 580 Megawatt capacity, is critical in maximizing the availability, performance, reliability, and maintainability of a power producing system. Operating the unit above the design operating point causes outages to occur sooner than scheduled. When the boiler is operated below the design operating point, fuel is wasted because the quantity of fuel required to operate a radiant boiler is the same, whether the design setpoint is maintained or not. This paper demonstrates by means of simulation software that the boiler design setpoints is critical to fuel consumption and optimum output megawatts. A boiler with this capacity is used to provide a portion of the base load of an electric utility in order to sustain revenues and maintain reliable generation.

Shwehdi, M.H. (Pennsylvania State Univ., Wilkes-Barre, Lehman, PA (United States)); Hughes, C.M. (Naval Aviation Depot, NAS Jacksonville, Jacksonville, FL (United States)); Quasem, M.A. (Howard Univ. School of Business, Washington, DC (United States))

1992-12-01T23:59:59.000Z

63

IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, VOL. 25, NO. 7, JULY 2006 1289 Profile-Guided Microarchitectural Floor Planning  

E-Print Network (OSTI)

IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, VOL. 25, NO. 7, JULY 2006 1289 Profile-Guided Microarchitectural Floor Planning for Deep Submicron Processor Design Mongkol integration (VLSI) process tech- nology migrates to nanoscale with a feature size of less than 100 nm, global

Lim, Sung Kyu

64

SunFloor 3D: A Tool for Networks on Chip Topology Synthesis for 3D Systems on Ciprian Seiculescu , Srinivasan Murali  

E-Print Network (OSTI)

SunFloor 3D: A Tool for Networks on Chip Topology Synthesis for 3D Systems on Chips Ciprian an efficient Network on Chip (NoC) intercon- nect for a 3D SoC that not only meets the application performance constraints, but also the constraints imposed by the 3D technology, is a significant challenge. In this work

De Micheli, Giovanni

65

Reverberatory screen for a radiant burner  

DOE Patents (OSTI)

The present invention relates to porous mat gas fired radiant burner panels utilizing improved reverberatory screens. The purpose of these screens is to boost the overall radiant output of the burner relative to a burner using no screen and the same fuel-air flow rates. In one embodiment, the reverberatory screen is fabricated from ceramic composite material, which can withstand higher operating temperatures than its metallic equivalent. In another embodiment the reverberatory screen is corrugated. The corrugations add stiffness which helps to resist creep and thermally induced distortions due to temperature or thermal expansion coefficient differences. As an added benefit, it has been unexpectedly discovered that the corrugations further increase the radiant efficiency of the burner. In a preferred embodiment, the reverberatory screen is both corrugated and made from ceramic composite material.

Gray, Paul E. (North East, MD)

1999-01-01T23:59:59.000Z

66

Radiant Barrier Performance during the Heating Season  

E-Print Network (OSTI)

in Combination with R-II and R-30 Ceiling Insulation." ORNLICON 239, Oak Ridge National Laboratory, Oak Ridge, TN. 13. Ober D.G. and Volckhausen T.W., 1988, "Radiant Barrier Insulation Performance in Full-Scale Attics with Soffit and Ridge Venting... in Combination with R-II and R-30 Ceiling Insulation." ORNLICON 239, Oak Ridge National Laboratory, Oak Ridge, TN. 13. Ober D.G. and Volckhausen T.W., 1988, "Radiant Barrier Insulation Performance in Full-Scale Attics with Soffit and Ridge Venting...

Medina, M. A.; O'Neal, D. L.; Turner, W. D.

67

Overview of the Radiant Time Series Method  

E-Print Network (OSTI)

/CLF procedure. 1988 ­ Sowell publishes results of 200,000+ DOE-2 calculations of custom weighting factors; Mc are published in ASHRAE Handbook of Fundamentals #12;RTSM Algorithm Conduction Gains Split all heat gains Provide Some Physical Insight Into the Nature of the Calculation #12;The Radiant Time Series Steady

68

First Floor1 Second Floor2  

E-Print Network (OSTI)

Resource Center Financial Counseling & Infusion Center Scheduling Lactation Room Meditation Garden Infusion Center Clinical Lab Waiting Playground Registration Infusion Center Waiting Second Floor Research Tower . . . . . . . . . . . . . . . . . .Second Conference Room 2250 . . . . . . . . . . . . . . . . . .Second Financial Counseling & Infusion

Gleeson, Joseph G.

69

DOE Zero Energy Ready Home Case Study, Clifton View Homes, Coupeville, WA, Systems Home  

Energy.gov (U.S. Department of Energy (DOE))

Case-study of a DOE Zero Energy Ready Home on Whidbey Island, WA, that scored HERS 45 without PV. This 2,908 ft2 custom/system home has a SIP roof and walls, R-20 rigid foam under slab, triple-pane windows, ground source heat pump for radiant floor heat, and a unique balanced ventilation system using separate exhaust fans to bring air into and out of home.

70

Radiant Electric Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Electric Coop, Inc Electric Coop, Inc Jump to: navigation, search Name Radiant Electric Coop, Inc Place Kansas Utility Id 15621 Utility Location Yes Ownership C NERC Location SPP Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates Residential: $0.1140/kWh Commercial: $0.1080/kWh Industrial: $0.0533/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Radiant_Electric_Coop,_Inc&oldid=411420" Categories: EIA Utility Companies and Aliases

71

Radiant Energy Power Source for Jet Aircraft  

SciTech Connect

This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.

Doellner, O.L.

1992-02-01T23:59:59.000Z

72

Cooling Energy Measurements of Houses with Attics Containing Radiant Barriers  

E-Print Network (OSTI)

Tests were conducted by Oak Ridge National Laboratory (ORNL) to determine the magnitude of the energy savings brought about by installing radiant barriers in the attics of single-family houses. The radiant barrier used for this test was a product...

Levins, W. P.; Karnitz, M. A.; Knight, D. K.

1986-01-01T23:59:59.000Z

73

Radiant Technology Corporation RTC | Open Energy Information  

Open Energy Info (EERE)

Technology Corporation RTC Technology Corporation RTC Jump to: navigation, search Name Radiant Technology Corporation (RTC) Place Fullerton, California Zip 92831 Product Provides infrared furnaces, primarily used in the photovoltaic manufacturing industry. Coordinates 46.16041°, -98.420506° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":46.16041,"lon":-98.420506,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

74

Alzeta porous radiant burner. CRADA final report  

SciTech Connect

An Alzeta Pyrocore porous radiant burner was tested for the first time at elevated pressures and mass flows. Mapping of the burner`s stability limits (flashback, blowoff, and lean extinction limits) in an outward fired configuration and hot wall environment was carried out at pressures up to 18 atm, firing rates up to 180 kW, and excess air rates up to 100%. A central composite experimental design for parametric testing within the stability limits produced statistically sound correlations of dimensionless burner temperature and NO{sub x} emissions as functions of equivalence ratio, dimensionless firing rate, and reciprocal Reynolds number. The NO{sub x} emissions were below 4 ppmvd at 15% O{sub 2} for all conditions tested, and the CO and unburned hydrocarbon levels were simultaneously low. As a direct result of this cooperative research effort between METC and Alzeta, Solar Turbines has already expressed a strong interest in this novel technology.

NONE

1995-12-01T23:59:59.000Z

75

Practical Analysis of a New Type Radiant Heating Technology in a Large Space Building  

E-Print Network (OSTI)

ICEBO2006, Shenzhen, China Heating technologies fo r energy efficiency Vol.III-3-4 Practical Analysis of a New Type Radiant Heating Technology in a Large Space Building Guohui Feng Guangyu Cao Li Gang Ph.D. Ph... achieve above 95%. Since not heating up indoor air, it is specially suited for heating of factory buildings where the conditions of heat preservation and sealing are poor and their gates are opened frequently. The off-on of radiation heating system...

Feng, G.; Cao, G.; Gang, L.

2006-01-01T23:59:59.000Z

76

Thermophotovoltaics for Combined Heat and Power Using Low NOx Gas Fired Radiant Tube Burners  

Science Journals Connector (OSTI)

Three new developments have now occurred making economical TPV systems possible. The first development is the diffused junction GaSb cell that responds out to 1.8 microns producing over 1 W/cm2 electric given a blackbody IR emitter temperature of 1250 C. This high power density along with a simple diffused junction cell makes an array cost of $0.50 per Watt possible. The second development is new IR emitters and filters that put 75% of the radiant energy in the cell convertible band. The third development is a set of commercially available ceramic radiant tube burners that operate at up to 1250 C. Herein we present near term and longer term spectral control designs leading to a 1.5 kW TPV generator / furnace incorporating these new features. This TPV generator / furnace is designed to replace the residential furnace for combined heat and power for the home.

Lewis Fraas; James Avery; Enrico Malfa; Joachim G. Wuenning; Gary Kovacik; Chris Astle

2003-01-01T23:59:59.000Z

77

Floor tube corrosion in recovery boilers  

SciTech Connect

Lower sulfur emissions at a pulp mill result in higher sulfidity levels and in the enrichment of potassium in the mill`s liquor system. The sulfidity values at Scandinavian kraft mills previously fluctuated between 28 and 35%; today they exceed 45%. Viscosity measurements show that the viscosity decreases drastically when the sulfidity increases from 30 mole% to 40 mole%, its potassium and chlorine levels are high enough, and the char bed is low, the smelt flows easily and may penetrate the char bed, approaching the floor tubes. In extreme cases, the hot smelt destroys the layer of solidified smelt on the floor tube`s surface and reacts very rapidly with the floor tube.

Klarin, A. [A. Ahistrom Corp., Helsinki (Finland)

1993-12-01T23:59:59.000Z

78

Walking on daylight : the application of translucent floor systems as a means of achieving natural daylighting in mid and low rise architecture  

E-Print Network (OSTI)

This thesis is concerned with the introduction of quality daylight to buildings by means of translucency in the horizontal planes or floors within the building. Since people began to build, the concept of translucency in ...

Widder, James

1985-01-01T23:59:59.000Z

79

XGSP-Floor: Floor Control for Synchronous and Ubiquitous Collaboration  

E-Print Network (OSTI)

1 XGSP-Floor: Floor Control for Synchronous and Ubiquitous Collaboration Kangseok Kim1, 2 , Wenjun of software/hardware technologies and wireless networking, there is coming a need for ubiquitous collaboration computing paradigms and collaborative applications, a workspace for working together is being expanded from

80

Preclinical Trial of a Radiant Heat Device for Whole-Body Hyperthermia Using a Porcine Model  

Science Journals Connector (OSTI)

...hyperthermia; RHD, radiant heat device; LDH, lactic...February 4,1983. radiant heat balance might eliminate...developed a prototype radiant heat device and conducted...comparable size and fat distribution; comparable hepatic...regulation via skin convectiva losses and via evaporative losses...

H. Ian Robins; Jeffrey Grossman; Thomas E. Davis; James P. AuBuchon; and Warren Dennis

1983-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Mean Radiant Cooling in a Hot-Humid Climate  

E-Print Network (OSTI)

Shaded interior mass walls in a hot-humid climate can be thermally grounded to an earth heat sink under an insulated structure. The mean radiant temperature (MRT) of the shaded and thermally grounded interior mass walls will be cooler in summer than...

Garrison, M.

1996-01-01T23:59:59.000Z

82

Vibrations of raised access floors  

Science Journals Connector (OSTI)

Raised access floors play a critical role in modern cleanroom design. They have unique mechanical properties that make them respond to dynamic loading in a manner quite different from conventional floors. For example an unbraced floor is much more flexible horizontally than in the vertical direction. Horizontal vibration amplitudes with walker excitation may exceed 100??m/s in an unbraced floor exceeding the sensitivity of 1000× inspection microscopes by as much as an order of magnitude. Issues such as these become important when moderately vibration?sensitive instruments such as optical microscopes are supported on access floors typically the case in cleanrooms. This paper presents results of experimental studies involving a 3?m×3?m segment of floor and a large floor installed in a cleanroom both of which were subjected to dynamic loads using a shaker. Both drive?point and propagation properties were examined. In addition data are presented for variations in bracing and bolting using the 3?m×3?m segment.

2002-01-01T23:59:59.000Z

83

Complete Theoretical Treatment of the Transmittance Ratio Ultraviolet/Visible Spectrophotometric Stray Radiant Energy Test Method  

Science Journals Connector (OSTI)

This paper develops the theoretical basis behind the transmittance ratio test method for determining the relative stray radiant energy level in a double-beam dispersive...

Fleming, Paddy

2009-01-01T23:59:59.000Z

84

From Shop Floor to Top Floor: Best Business Practices in Energy...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Efficiency This document is the presentation delivered on the Pew Center on Global Climate Change's report From Shop Floor to Top Floor: Best Business Practices in Energy...

85

Super-radiant backward-wave oscillators with enhanced power conversion  

SciTech Connect

We propose a method for a very significant increase of the peak power of a backward-wave electron oscillator operating in the non-stationary regime of the super-radiation of short rf pulses. This method is based on sectioning: a regular self-oscillator section is supported with a section providing amplification of the super-radiant pulse. Profiling of a resonant parameter in the amplifying section is used to avoid the parasitic self-excitation and to increase the efficiency of the electron-wave interaction. In such systems, the conversion factor (the ratio between the rf pulse power and the electron beam power) can achieve a few hundred percent.

Rostov, V. V. [Institute of High Current Electronics, Siberian Branch of Russian Academy of Science, Tomsk (Russian Federation); Savilov, A. V. [Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia, and Lobachevsky State University of Nizhny Novgorod (Russian Federation)

2013-02-15T23:59:59.000Z

86

From Shop Floor to Top Floor: Best Business Practices in Energy Efficiency  

Open Energy Info (EERE)

From Shop Floor to Top Floor: Best Business Practices in Energy Efficiency From Shop Floor to Top Floor: Best Business Practices in Energy Efficiency Jump to: navigation, search Tool Summary LAUNCH TOOL Name: From Shop Floor to Top Floor: Best Business Practices in Energy Efficiency Agency/Company /Organization: Pew Center on Global Climate Change Sector: Energy Focus Area: Energy Efficiency Topics: Policies/deployment programs Resource Type: Lessons learned/best practices Website: www.pewclimate.org/docUploads/PEW_EnergyEfficiency_FullReport.pdf References: From Shop Floor to Top Floor: Best Business Practices in Energy Efficiency[1] FROM SHOP FLOOR TO TOP FLOOR: BEST BUSINESS PRACTICES IN ENERGY EFFICIENCY. Pew Center on Global Climate Change. William R. Prindle. April 2010. In the last decade, rising and volatile energy prices coupled with

87

Guidelines for Modeling Based on Experiences with Radiantly Stabilized Combustion  

Science Journals Connector (OSTI)

The experimental measurements were confined to the central channel, and the other six were considered to be “guard heaters” to minimize radial heat losses. ... “Flameless incandescent surface combustion” was, according to Bone and Townend,8 actually identified by that name by Bone and M'Court, who, in the period of 1906?1909, observed for the combustion of a mixture of a gaseous fuel and air in various types of porous media “an intensely glowing surface ? a veritable wall of fire, but without a flame ? throwing out a genial radiant heat, .... the surface temperature being about 900° to 1000 °C”. ... They also produced one great surprise, namely that the internal heat transfer coefficient corresponding to the uniform heating varied radically with length for some conditions, including the attainment of unbounded and negative values. ...

Stuart W. Churchill

2008-03-29T23:59:59.000Z

88

Radiant energy receiver having improved coolant flow control means  

DOE Patents (OSTI)

An improved coolant flow control for use in radiant energy receivers of the type having parallel flow paths is disclosed. A coolant performs as a temperature dependent valve means, increasing flow in the warmer flow paths of the receiver, and impeding flow in the cooler paths of the receiver. The coolant has a negative temperature coefficient of viscosity which is high enough such that only an insignificant flow through the receiver is experienced at the minimum operating temperature of the receiver, and such that a maximum flow is experienced at the maximum operating temperature of the receiver. The valving is accomplished by changes in viscosity of the coolant in response to the coolant being heated and cooled. No remotely operated valves, comparators or the like are needed.

Hinterberger, H.

1980-10-29T23:59:59.000Z

89

American Energy Power Systems Inc AEPS | Open Energy Information  

Open Energy Info (EERE)

Inc AEPS Inc AEPS Jump to: navigation, search Name American Energy Power Systems Inc (AEPS) Place Sacramento, California Sector Solar Product Offered distributed power systems including PV panels, solar water heating, fuel cells and radiant floor heating applications. References American Energy Power Systems Inc (AEPS)[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. American Energy Power Systems Inc (AEPS) is a company located in Sacramento, California . References ↑ "American Energy Power Systems Inc (AEPS)" Retrieved from "http://en.openei.org/w/index.php?title=American_Energy_Power_Systems_Inc_AEPS&oldid=342116" Categories: Clean Energy Organizations

90

Design and Control of Hydronic Radiant Cooling Systems  

E-Print Network (OSTI)

141 Appendix B: David Brower Center building modelingBrower Center building modeling information Construction anda standard building energy modeling platform. Communication

Feng, Jingjuan Dove

2014-01-01T23:59:59.000Z

91

Design and Control of Hydronic Radiant Cooling Systems  

E-Print Network (OSTI)

normalized mean bias error SHGC Solar heat gain coefficientwas 2.721 W/(m 2. K) with Glass SHGC at 0.788. The baselinevalue of 2.721 W/m 2 ·K and SHGC of 0.788 and the total area

Feng, Jingjuan Dove

2014-01-01T23:59:59.000Z

92

Design and Control of Hydronic Radiant Cooling Systems  

E-Print Network (OSTI)

air temperature control Supply air temperature from the aircombined with supply water temperature control (Gwerder etflow, variable-supply water temperature control can save up

Feng, Jingjuan Dove

2014-01-01T23:59:59.000Z

93

Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes...  

Energy Savers (EERE)

Air-to-Water Heat Pumps With Radiant Delivery in Low Load Homes Tucson, Arizona and Chico, California PROJECT INFORMATION Project Name: Field testing of air-to-water heat pump...

94

Numerical modeling of the ignition of a liquid hydrocarbon layer by a radiant heat pulse  

Science Journals Connector (OSTI)

A gas-phase model of radiative ignition of a flammable liquid is developed, allowing for absorption of the radiant flux in the gas phase. Using motor fuels (gasoline and diesel fuel), as examples, we demonstra...

Yu. V. Agabekov; F. G. Yagafarov

95

Computation of electric-arc parameters taking account of convective and radiant losses  

Science Journals Connector (OSTI)

An approximate solution of the problem of an electrical arc in a turbulent argon stream is obtained, taking into account convective and radiant energy losses in the discharge channel at atmospheric pressure.

N. A. Zyrichev

1971-10-01T23:59:59.000Z

96

Relative radiant heat absorption characteristics of two types of mirror shields and a polished aluminum shield  

E-Print Network (OSTI)

RELATIVE RADIANT HEAT ABSORPTION CHARACTERISTICS OF TWO TYPES OF MIRROR SHIELDS AND A POLISHED ALUMINUM SHIELD A Thesis by STEVEN DOUGLAS HERRON Submitted to the Graduate College of Texas A&M University in partial fulfillment... of the requirement for the degree of MASTER OF SCIENCE August 1973 Major Subject: Industrial Hygiene RELATIVE RADIANT HEAT ABSORPTION CHARACTERISTICS OF TWO TYPES OF MIRROR SHIELDS AND A POLISHED ALUMINUM SHIELD A Thesis by STEVEN DOUGLAS HERRON Approved...

Herron, Steven Douglas

2012-06-07T23:59:59.000Z

97

A quasi-steady state model to predict attic heat transfer and energy savings in residences using radiant barriers  

E-Print Network (OSTI)

[10-14] for Oak Ridge National Laboratories (ORNL) has focused on comparing energy reduction on three experimental houses operated by ORNL. Their research has consisted of both summer and winter tests of radiant barriers. Radiant Barrier...A QUASI-STEADY STATE MODEL TO PREDICT ATTIC HEAT TRANSFER AND ENERGY SAVINGS IN RESIDENCES USING RADIANT BARRIERS A Thesis by DAVID WALTER WINIARSKI Submitted to the Office of Graduate Studies of Texas ARM University in partial fulfillment...

Winiarski, David Walter

2012-06-07T23:59:59.000Z

98

Save Energy Now (SEN) Assessment Helps Expand Energy Management Program at Shaw Industries: Flooring Company Saves $872,000 Annually by Improving Steam System Efficiency  

SciTech Connect

This case study describes how the Shaw Industries plant #20 in Dalton, Georgia, achieved annual savings of $872,000 and 93,000 MMBtu after receiving a DOE Save Energy Now energy assessment and implementing recommendations to improve the efficiency of its steam system.

Not Available

2008-07-01T23:59:59.000Z

99

E-Print Network 3.0 - advanced launch system Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Microwave Sounder CERES Clouds and the Earth's Radiant Energy System CrIS Crosstrack... Weather Satellite System FY Fiscal Year GAO Government Accountability Office GOES...

100

Floor Buffer Guidelines Floor buffers can expose employees to noise, hazardous materials, and hazards related to  

E-Print Network (OSTI)

as possible. 3. Custodial staff should receive training on the safe operation of the machines, pads, and floor floors. 5. Select the least abrasive pad for stripping operations. 6. Do not over-strip, and stop and use of hearing protection. Propane Re-filling Only trained and qualified personnel may refill propane

de Lijser, Peter

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Brief Communication Effect of asymmetric radiant heating on monodisperse acetone/ethanol  

E-Print Network (OSTI)

Brief Communication Effect of asymmetric radiant heating on monodisperse acetone/ethanol, exploring bi-component droplets of ace- tone/ethanol and acetone/2-propanol mixtures. The ethanol and 2-component droplets composed of acetone/ethanol and acetone/ 2-propanol mixtures (1:1 volume ratio). Fig. 1 shows

Miller, Richard S.

102

Radiant flux from Earth's subaerially erupting volcanoes R. WRIGHT* and E. PILGER  

E-Print Network (OSTI)

Radiant flux from Earth's subaerially erupting volcanoes R. WRIGHT* and E. PILGER Hawaii Institute have been used to estimate lava effusion rates (Harris et al. 1997a, Wright et al. 2001), constrain lava flow thermal budgets (Pieri et al. 1990, Wright et al. 2000), deduce the explosive potential

Wright, Robert

103

An Efficient Instantiation Algorithm for Simulating Radiant Energy Transfer in Plant Models  

E-Print Network (OSTI)

in agronomy concerning the influence of light over the production of a cultivated crop under differentAn Efficient Instantiation Algorithm for Simulating Radiant Energy Transfer in Plant Models Cyril simu- lation of light energy exchange inside plants models. This is obviously useful for visual

Boyer, Edmond

104

SIMON: A mobile robot for floor contamination surveys  

SciTech Connect

The Robotics Development group at the Savannah River Site is developing an autonomous robot to perform radiological surveys of potentially contaminated floors. The robot scans floors at a speed of one-inch/second and stops, sounds an alarm, and flashes lights when contamination in a certain area is detected. The contamination of interest here is primarily alpha and beta-gamma. The contamination levels are low to moderate. The robot, a Cybermotion K2A, is radio controlled, uses dead reckoning to determine vehicle position, and docks with a charging station to replenish its batteries and calibrate its position. It has an ultrasonic collision avoidance system as well as two safety bumpers that will stop the robot's motion when they are depressed. Paths for the robot are preprogrammed and the robot's motion can be monitored on a remote screen which shows a graphical map of the environment. The radiation instrument being used is an Eberline RM22A monitor. This monitor is microcomputer based with a serial I/O interface for remote operation. Up to 30 detectors may be configured with the RM22A. For our purposes, two downward-facing gas proportional detectors are used to scan floors, and one upward-facing detector is used for radiation background compensation. SIMON is interfaced with the RM22A in such a way that it scans the floor surface at one-inch/second, and if contamination is detected, the vehicle stops, alarms, and activates a voice synthesizer. Future development includes using the contamination data collected to provide a graphical contour map of a contaminated area. 3 refs.

Dudar, E.; Teese, G.; Wagner, D.

1991-01-01T23:59:59.000Z

105

SIMON: A mobile robot for floor contamination surveys  

SciTech Connect

The Robotics Development group at the Savannah River Site is developing an autonomous robot to perform radiological surveys of potentially contaminated floors. The robot scans floors at a speed of one-inch/second and stops, sounds an alarm, and flashes lights when contamination in a certain area is detected. The contamination of interest here is primarily alpha and beta-gamma. The contamination levels are low to moderate. The robot, a Cybermotion K2A, is radio controlled, uses dead reckoning to determine vehicle position, and docks with a charging station to replenish its batteries and calibrate its position. It has an ultrasonic collision avoidance system as well as two safety bumpers that will stop the robot`s motion when they are depressed. Paths for the robot are preprogrammed and the robot`s motion can be monitored on a remote screen which shows a graphical map of the environment. The radiation instrument being used is an Eberline RM22A monitor. This monitor is microcomputer based with a serial I/O interface for remote operation. Up to 30 detectors may be configured with the RM22A. For our purposes, two downward-facing gas proportional detectors are used to scan floors, and one upward-facing detector is used for radiation background compensation. SIMON is interfaced with the RM22A in such a way that it scans the floor surface at one-inch/second, and if contamination is detected, the vehicle stops, alarms, and activates a voice synthesizer. Future development includes using the contamination data collected to provide a graphical contour map of a contaminated area. 3 refs.

Dudar, E.; Teese, G.; Wagner, D.

1991-12-31T23:59:59.000Z

106

Thermal capacity of composite floor slabs  

Science Journals Connector (OSTI)

AbstractObjective Thermal building simulation tools take account of the thermal capacity of the walls and floors by a one-dimensional characterization. The objective was to obtain thermal equivalent parameters for ribbed or composite slab elements that can be input into one-dimensional models. Method Transient finite element calculations (FEM) were used to establish the heat transfer to and from composite floors using four deck profiles and for daily heating cycles in compartments with defined heat gains and operating conditions. Results The performance of composite slabs was compared to a concrete flat slab for a typical office in the UK and Germany. It was shown that a deep ribbed slab generates a maximum heat flux of 30.5 W/m2 for a 5 °C temperature variation about the mean, and that the daily heat absorbed by a typical composite slab was 220 Wh/m2 floor area. Conclusions Using the thermal capacity of the ribbed floor slabs, the comfort conditions defined in terms of the number of hours over 25 °C are acceptable for many classes of offices. Practical implications Thermally equivalent properties of ribbed slabs can be used in conventional software to predict the thermal performance.

B. Doering; C. Kendrick; R.M. Lawson

2013-01-01T23:59:59.000Z

107

Property:Building/FloorAreaOtherRetail | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search This is a property of type Number. Floor area for Other retail Pages using the property "BuildingFloorAreaOtherRetail" Showing 1 page using this...

108

Property:Building/FloorAreaHealthServicesDaytime | Open Energy...  

Open Energy Info (EERE)

Jump to: navigation, search This is a property of type Number. Floor area for Daytime health services Pages using the property "BuildingFloorAreaHealthServicesDaytime" Showing 4...

109

Electron storage ring BESSY as a radiometric source of calculable spectral radiant power between 0.5 and 1000 nm  

Science Journals Connector (OSTI)

The spectral radiant power of the electron storage ring BESSY was measured absolutely in the infrared and visible, and its angular distribution in the infrared, visible, and soft-x-ray...

Riehle, F; Wende, B

1985-01-01T23:59:59.000Z

110

Numerical evaluation of the thermal performances of roof-mounted radiant barriers  

E-Print Network (OSTI)

This paper deals with the thermal performances of roof-mounted radiant barriers. Using dynamic simulations of a mathematical model of a whole test cell including a radiant barrier installed between the roof top and the ceiling, the thermal performance of the roof is calculated. The mean method is more particularly used to assess the thermal resistance of the building component and lead to a value which is compared to the one obtained for a mass insulation product such as polyurethane foam. On a further stage, the thermal mathematical model is replaced by a thermo-aeraulic model which is used to evaluate the thermal resistance of the roof as a function of the airflow rate. The results shows a better performance of the roof in this new configuration, which is widely used in practice. Finally, the mathematical relation between the thermal resistance and the airflow rate is proposed.

Miranville, Frédéric; Lucas, Franck; Johan, Seriacaroupin

2014-01-01T23:59:59.000Z

111

Prediction of Floor Water Inrush: The Application of GIS-Based AHP Vulnerable Index Method to Donghuantuo Coal Mine, China  

Science Journals Connector (OSTI)

Floor water inrush represents a geohazard that can pose significant threat to safe operations for instance in coal mines in China and elsewhere. Its occurrence ... process (AHP) and geographic information system ...

Qiang Wu; Yuanzhang Liu; Donghai Liu; Wanfang Zhou

2011-09-01T23:59:59.000Z

112

Floor Support | Stanford Synchrotron Radiation Lightsource  

NLE Websites -- All DOE Office Websites (Extended Search)

Floor Support Floor Support Service Responsible Person BLDG Extension (650) 926-XXXX Beam Status Duty Operator 120 926-2326 (BEAM) Duty Operator Cell Duty Operator 120 926-4040 Scheduling X-ray/VUV Macromolecular Crystallography Cathy Knotts Lisa Dunn 120 120 3191 2087 User Check-In/Badging Jackie Kerlegan 120 2079 User Financial Accounts Jackie Kerlegan 120 2079 Beam Lines/ VUV Bart Johnson 120 3858 Beam Lines/ X-ray Bart Johnson 120 3858 Beam Lines/ X-ray Mechanical Chuck Troxel, Jr. 120 2700 Beam Lines/ X-ray-VUV Electronics Alex Garachtchenko 120 3440 Beam Lines/ Macromolecular Crystallography Mike Soltis 277 3050 SMB XAS Beam Lines & Equipment Matthew Latimer Erik Nelson 274 274 4944 3938 MEIS XAS Beam Lines & Equipment Matthew Latimer

113

User ESH Support (UES)/Floor Coordinators  

NLE Websites -- All DOE Office Websites (Extended Search)

User ESH Support (UES) / Floor Coordinators User ESH Support (UES) / Floor Coordinators Bruce Glagola, Group Leader Building 431, Room Z005 Phone: 630-252-9797 Fax: 630-252-1664 E-mail: glagola@aps.anl.gov Nena Moonier Building 431, Room Z008 Phone: 630-252-8504 Fax: 630-252-1664 E-mail: nmoonier@aps.anl.gov Karen Kucer Building 401, Room C3257C Phone: 630-252-9091 Fax: 630-252-5948 E-mail: kucer@aps.anl.gov Floor Coordinators Bruno Fieramosca Building 432, Room C001 Phone: 630-252-0201 Fax: 630-252-1664 On-site page: 4-0201 E-mail: bgf@aps.anl.gov Shane Flood Building 436, Room C001 Phone: 630-252-0600 Fax: 630-252-1664 On-site pager: 4-0600 E-mail: saf@aps.anl.gov Patti Pedergnana Building 434, Room C001 Phone: 630-252-0401 Fax: 630-252-1664 On-site pager: 4-0401 E-mail: neitzke@aps.anl.gov Wendy VanWingeren Building 435, Room C001

114

Theory and practice of continuous improvement in shop-floor teams  

Science Journals Connector (OSTI)

Most publications about Continuous Improvement (CI) stress the importance, and describe practical applications, of CI. Practicable, i.e. useful and usable, theories that help organisations to make appropriate decisions when adopting, implementing, operating and continuously improving a CI system are relatively few. Concentrating on one particular form of CI, i.e., shop-floor improvement teams, the aim of the present article is to contribute to the development of such a practicable theory about CI. Based on insights given by contingency theory and empirical observations, the article explores and explains the functioning of shop-floor improvement teams and their contribution to the CI.

Ellen de Lange-Ros; Harry Boer

2001-01-01T23:59:59.000Z

115

AEDG Implementation Recommendations: Floors | Building Energy Codes Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Floors Floors The Advanced Energy Design Guide (AEDG) for Small Office Buildings, 30% series, seeks to achieve 30% savings over ASHRAE Standard 90.1-1999. This guide focuses on improvements to small office buildings, less than 20,000ft2. The recommendations in this article are adapted from the implementation section of the guide and focus on mass floors; steel joist or wood frame floors; slab-on-grade floors. Publication Date: Wednesday, May 13, 2009 air_floors.pdf Document Details Affiliation: DOE BECP Focus: Compliance Building Type: Commercial Code Referenced: ASHRAE Standard 90.1-1999 Document type: AEDG Implementation Recommendations Target Audience: Architect/Designer Builder Contractor Engineer State: All States Contacts Web Site Policies U.S. Department of Energy

116

Occupant Response to Window Control Signaling Systems  

E-Print Network (OSTI)

Air Conditioning   Fan coil units, variable refrigerant active cooling via fan coil units and radiant panels, system to perimeter fan coil units, and “open”  mode for 

Ackerly, Katherine

2012-01-01T23:59:59.000Z

117

Improvement in impact insulation ratings of common floor/ceiling assemblies in multi?family dwellings with standard floor coverings  

Science Journals Connector (OSTI)

Improvement in the field?rated impact insulation class [FIIC] was measured for several common floor/ceiling assemblies in existing multi?family buildings utilizing several standard grades of carpet pad and various vinyl products. Testing included determination of FIIC ratings with existing floor coverings and with other more effective floor coverings including ordinary cushioned vinyl thickly cushion?backed vinyl and vinyl products with fiber board and particle board underlayment. Test results indicate that a significant improvement in the FIIC ratings of existing vinyl covered floor/ceiling assemblies can be achieved by the superposition of an appropriate cushioned vinyl on top of the existing standard vinyl. The test results also indicate that a significant increase in FIIC ratings of existing carpeted floor/ceiling assemblies can be achieved by appropriate selection of new pad and carpet. Test data from measurements performed in accordance with ISO recommendation R140 are presented in the paper for several representative configurations.

Stanley M. Rosen

1981-01-01T23:59:59.000Z

118

Radiant heating tests of several liquid metal heat-pipe sandwich panels  

SciTech Connect

Integral heat pipe sandwich panels, which synergistically combine the thermal efficiency of heat pipes and the structural efficiency of honeycomb sandwich construction, were conceived as a means of alleviating thermal stress problems in the Langley Scramjet Engine. Test panels which utilized two different wickable honeycomb cores, facesheets with screen mesh sintered to the internal surfaces, and a liquid metal working fluid (either sodium or potassium) were tested by radiant heating at various heat load levels. The heat pipe panels reduced maximum temperature differences by 31 percent with sodium working fluid and 45 percent with potassium working fluid. Results indicate that a heat pipe sandwich panel is a potential, simple solution to the engine thermal stress problem. Other interesting applications of the concept include: cold plates for electronic component and circuit card cooling, radiators for large space platforms, low distortion large area structures (e.g., space antennas) and laser mirrors.

Camarda, C.J.; Basiulis, A.

1983-08-01T23:59:59.000Z

119

Uncertainty of Radiant Power Calibration based on Synchrotron Radiation caused by Spectral Distribution and Polarization State  

SciTech Connect

We have been attempting to establish an absolute scale of spectral radiance in ultraviolet and vacuum ultraviolet regions by using synchrotron radiation as a primary standard light source and also attempting to transfer the absolute scale to an under-test light source by comparing the under-test source with synchrotron radiation. The calibration apparatus does not function as ideal comparator because some properties of incident radiation, which are spectral distribution and polarization state, are different between synchrotron radiation and the under-test light source, and the signal of the apparatus accordingly depends on not only spectral radiant power but also depends on the properties of the incident radiation. We evaluated how the detector signal ratio was affected by the difference both experimentally and theoretically, and also evaluated the uncertainty of the scale transfer caused by the difference.

Zama, Tatsuya; Saito, Ichiro [National Institute of Advanced Industrial Science and Technology (AIST), National Metrology Institute of Japan (NMIJ) (Japan)

2010-06-23T23:59:59.000Z

120

Property:Building/FloorAreaRestaurants | Open Energy Information  

Open Energy Info (EERE)

Property Property Edit with form History Facebook icon Twitter icon » Property:Building/FloorAreaRestaurants Jump to: navigation, search This is a property of type Number. Floor area for Restaurants Pages using the property "Building/FloorAreaRestaurants" Showing 13 pages using this property. S Sweden Building 05K0007 + 1,990 + Sweden Building 05K0008 + 300 + Sweden Building 05K0013 + 215 + Sweden Building 05K0038 + 345 + Sweden Building 05K0046 + 200 + Sweden Building 05K0058 + 330 + Sweden Building 05K0060 + 256 + Sweden Building 05K0065 + 520 + Sweden Building 05K0081 + 98 + Sweden Building 05K0089 + 155 + Sweden Building 05K0098 + 170 + Sweden Building 05K0105 + 2,450 + Sweden Building 05K0114 + 400 + Retrieved from "http://en.openei.org/w/index.php?title=Property:Building/FloorAreaRestaurants&oldid=285973#SMWResults"

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Property:Building/FloorAreaMiscellaneous | Open Energy Information  

Open Energy Info (EERE)

FloorAreaMiscellaneous FloorAreaMiscellaneous Jump to: navigation, search This is a property of type Number. Floor area for Miscellaneous Pages using the property "Building/FloorAreaMiscellaneous" Showing 25 pages using this property. S Sweden Building 05K0002 + 360 + Sweden Building 05K0005 + 110 + Sweden Building 05K0013 + 3,550 + Sweden Building 05K0016 + 445 + Sweden Building 05K0021 + 250 + Sweden Building 05K0025 + 254 + Sweden Building 05K0035 + 1,629 + Sweden Building 05K0037 + 175 + Sweden Building 05K0040 + 869 + Sweden Building 05K0044 + 1,234 + Sweden Building 05K0047 + 1,039 + Sweden Building 05K0051 + 1,489.92 + Sweden Building 05K0052 + 200 + Sweden Building 05K0062 + 140 + Sweden Building 05K0063 + 654 + Sweden Building 05K0068 + 746 + Sweden Building 05K0071 + 293 +

122

NSLS-II Source Properties and Floor Layout  

NLE Websites -- All DOE Office Websites (Extended Search)

NSLS-II Source Properties and Floor Layout NSLS-II Source Properties and Floor Layout April 12, 2010 Contents Basic Storage Ring Parameters Basic and Advanced Source Parameters Brightness Flux Photon Source Size and Divergence Power Infrared Sources Distribution of Sources Available for User Beamlines Floor Layout This document provides a summary of the current NSLS-II source and floor layout parameters. For a more complete description of the NSLS-II accelerator properties planned for NSLS-II, see the NSLS-II Preliminary Design Report Basic NSLS-II Storage Ring Parameters at NSLS-II website. We note that this document summarizes the present status of the design, but that the design continues to be refined and that these parameters may change as part of this process. NSLS-II is designed to deliver photons with high average spectral brightness in the 2 keV to 10 keV

123

Full-scale shear tests of embedded floor modules  

SciTech Connect

A floor module used to support a centrifuge machine is a steel framework embedded in a 2-ft (610-mm) thick concrete slab. This steel framework is made up of four cylindrical hollow sockets tied together with four S-beams to form a square pattern. In the event of a centrifuge machine wreck, large forces are transmitted from the machine to the corner sockets (through connecting steel lugs) and to the concrete slab. The floor modules are loaded with a combination of torsion and shear forces in the plane of the floor slab. Precisely how these wreck loads are transmitted to, and reacted by, the floor modules and the surrounding concrete was the scope of a series of full-scale tests performed at the DOE Gas Centrifuge Enrichment Plant (GCEP) located near Piketon, Ohio. This report describes the tests and the results of the data reduction to date.

Fricke, K.E.; Jones, W.D.; Burdette, E.G.

1984-01-01T23:59:59.000Z

124

Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes: Tucson, Arizona and Chico, California (Fact Sheet)  

SciTech Connect

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

Not Available

2013-11-01T23:59:59.000Z

125

Development of periodic response factors for use with the radiant time series method  

SciTech Connect

Harris and McQuiston (1988) developed conduction transfer function (CTF) coefficients corresponding to 41 representative wall assemblies and 42 representative roof assemblies for use with the transfer function method (TFM). They also developed a grouping procedure that allows design engineers to determine the correct representative wall or roof assembly that most closely matches a specific wall or roof assembly. The CTF coefficients and the grouping procedure have been summarized in the ASHRAE Handbook--Fundamentals (1989, 1993, 1997) and the ASHRAE Cooling and Heating Load Calculation Manual, second edition. More recently, a new, simplified design cooling load calculation procedure, the radiant time series method (RTSM), has been developed. The RTSM uses periodic response factors to model transient conductive heat transfer. While not a true manual load calculation procedure, it is quite feasible to implement the RTSM in a spreadsheet. To be useful in such an environment, it would be desirable to have a pre-calculated set of periodic response factors. Accordingly, a set of periodic response factors has been calculated and is presented in this paper.

Spitler, J.D.; Fisher, D.E.

1999-07-01T23:59:59.000Z

126

A radiant flow reactor for high?temperature reactivity studies of pulverized solids  

Science Journals Connector (OSTI)

Our radiant two?phase flow reactor presents several new possibilities for high?temperature reactivity studies. Most importantly the thermal histories of the suspension and entrainment gas can be independently regulated over wide ranges. At low suspension loadings outlet temperatures can differ by hundreds of degrees and gas temperatures are low enough to inhibit hydrocarbon cracking chemistry so primary products are quenched as soon as they are expelled. With coal suspensions tars were generated with the highest H/C ratio and lowest proton aromaticity ever reported. Alternatively particles and gas can be heated at similar rates to promote secondary chemistry by increasing particle loading. Simply by regulating the furnace temperature arbitrary extents of conversion of coal tar into soot were observed for fixed total mass loss. Under both circumstances heat fluxes are comparable to those in large furnaces so relevant heating rates and reaction times are accessible. Suspensions remain optically thin even for the highest loadings of technological interest because they are only 1 cm wide. Consequently the macroscopic behavior remains firmly connected to single?particle phenomena. Mass and elemental closures are rarely breached by more than 5% in individual runs so interpretations are not subject to inordinate scatter in the data. The reactor is also well suited for combustion studies as demonstrated by extents of carbon and nitrogen burnout from 50% to 100% for various gas?stream oxygen levels.

John C. Chen; Stephen Niksa

1992-01-01T23:59:59.000Z

127

Property:Building/TotalFloorArea | Open Energy Information  

Open Energy Info (EERE)

Property Property Edit with form History Facebook icon Twitter icon » Property:Building/TotalFloorArea Jump to: navigation, search This is a property of type Number. Total floor area (BRA), m2 Pages using the property "Building/TotalFloorArea" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 19,657 + Sweden Building 05K0002 + 7,160 + Sweden Building 05K0003 + 4,855 + Sweden Building 05K0004 + 25,650 + Sweden Building 05K0005 + 2,260 + Sweden Building 05K0006 + 13,048 + Sweden Building 05K0007 + 24,155 + Sweden Building 05K0008 + 7,800 + Sweden Building 05K0009 + 34,755 + Sweden Building 05K0010 + 437 + Sweden Building 05K0011 + 15,310 + Sweden Building 05K0012 + 22,565 + Sweden Building 05K0013 + 19,551 +

128

Property:Building/FloorAreaShops | Open Energy Information  

Open Energy Info (EERE)

Property Property Edit with form History Facebook icon Twitter icon » Property:Building/FloorAreaShops Jump to: navigation, search This is a property of type Number. Floor area for Shops Pages using the property "Building/FloorAreaShops" Showing 19 pages using this property. S Sweden Building 05K0002 + 900 + Sweden Building 05K0009 + 800 + Sweden Building 05K0012 + 1,587 + Sweden Building 05K0013 + 154 + Sweden Building 05K0017 + 3,150 + Sweden Building 05K0018 + 245 + Sweden Building 05K0019 + 5,600 + Sweden Building 05K0035 + 292 + Sweden Building 05K0046 + 530 + Sweden Building 05K0062 + 940 + Sweden Building 05K0081 + 530 + Sweden Building 05K0086 + 920 + Sweden Building 05K0088 + 1,170 + Sweden Building 05K0089 + 976 + Sweden Building 05K0092 + 360 +

129

Property:Building/FloorAreaHeatedGarages | Open Energy Information  

Open Energy Info (EERE)

Property Property Edit with form History Facebook icon Twitter icon » Property:Building/FloorAreaHeatedGarages Jump to: navigation, search This is a property of type Number. Floor area for Heated garages (> 10 °C) Pages using the property "Building/FloorAreaHeatedGarages" Showing 15 pages using this property. S Sweden Building 05K0002 + 900 + Sweden Building 05K0007 + 400 + Sweden Building 05K0020 + 300 + Sweden Building 05K0022 + 3,300 + Sweden Building 05K0031 + 2,331 + Sweden Building 05K0033 + 465 + Sweden Building 05K0035 + 1,276 + Sweden Building 05K0037 + 130 + Sweden Building 05K0039 + 580 + Sweden Building 05K0047 + 1,076 + Sweden Building 05K0048 + 340 + Sweden Building 05K0061 + 90 + Sweden Building 05K0067 + 856 + Sweden Building 05K0093 + 2,880 +

130

DOE Zero Energy Ready Home Case Study, Ferguson Design and Constructio...  

Energy Savers (EERE)

with R-40 blown cellulose, R-10 XPS under slab, a hydro air system with 91% efficient boiler for forced air and radiant floor heat, and 100% LED lights. Ferguson Design &...

131

Property:Building/FloorAreaOffices | Open Energy Information  

Open Energy Info (EERE)

FloorAreaOffices FloorAreaOffices Jump to: navigation, search This is a property of type Number. Floor area for Offices Pages using the property "Building/FloorAreaOffices" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 19,657 + Sweden Building 05K0002 + 5,000 + Sweden Building 05K0003 + 4,360 + Sweden Building 05K0004 + 25,650 + Sweden Building 05K0005 + 2,150 + Sweden Building 05K0006 + 13,048 + Sweden Building 05K0007 + 21,765 + Sweden Building 05K0008 + 7,500 + Sweden Building 05K0009 + 33,955 + Sweden Building 05K0010 + 437 + Sweden Building 05K0011 + 14,080 + Sweden Building 05K0012 + 20,978 + Sweden Building 05K0013 + 15,632 + Sweden Building 05K0014 + 1,338.3 + Sweden Building 05K0015 + 1,550 + Sweden Building 05K0016 + 2,101 +

132

Viscosity Control of the Composition of Ocean Floor Volcanics  

Science Journals Connector (OSTI)

4 February 1971 research-article Viscosity Control of the Composition of Ocean Floor...environment. Instead it is postulated that the viscosity exercises a control by limiting the range...magmas (to those with a sufficiently low viscosity) which is capable of penetrating the...

1971-01-01T23:59:59.000Z

133

716 Langdon St 2nd Floor Red Gym  

E-Print Network (OSTI)

716 Langdon St 2nd Floor Red Gym Madison WI 53706 (608) 262-4503 http://msc.wisc.edu 1 FOLLOW OUR of witnesses may always go before you and walk beside you. We bestow a red and white kente stole upon all of our graduates. Red, for passion and sacrifice. White, for initiation and new beginnings. Each stole

Sheridan, Jennifer

134

Lunar floor-fractured craters: Classification, distribution, origin and implications for magmatism and shallow crustal structure  

E-Print Network (OSTI)

Floor-Fractured Craters (FFCs) are a class of lunar craters characterized by anomalously shallow floors cut by radial, concentric, and/or polygonal fractures; additional interior features are moats, ridges, and patches of ...

Jozwiak, Lauren M.

135

The use of phase change materials in domestic heat pump and air-conditioning systems for short term storage: A review  

Science Journals Connector (OSTI)

Abstract Heat pumps for space heating and cooling are a mature and highly efficient technology that can take advantage of renewable energies. They can also provide energy savings by load shifting when they operate together with thermal energy storage (TES). This paper presents a literature review of TES systems using phase change materials (PCM) potentially applicable to domestic heat pumps used in residential and administrative buildings. The paper describes the systems proposed by the different authors and presents the main conclusions of the studies. The TES systems presented are not only used as energy storage to shift the load demand but also for other applications such as heat recovery or defrosting in air-conditioners. The PCM have the suitable melting temperature to work together with standard heat pumps in each application. Moreover, some systems where the heat pump is coupled to latent heat thermal energy storage (LHTES) units and other energy sources or where the TES system is incorporated in a radiant floor or air distribution system have also been included.

Pere Moreno; Cristian Solé; Albert Castell; Luisa F. Cabeza

2014-01-01T23:59:59.000Z

136

Forest floor bulk density and depth at Savannah River - Draft Final Report.  

SciTech Connect

Knowing the amount of biomass across a landscape is becoming increasingly important to fire managers as new fuel and fire management decision support systems come on line. Fire managers rarely have the time or funding available to sample fuels operationally and often depend upon mean values for critical variables whose variation is often associated with simple stand characteristics such as age, forest type, time since last burn, stocking, or site, and other easily measured variables. This report outlines a study to collect and analyze litter and duff bulk density samples for developing a simple predictive tool to estimate forest floor fuel loading based on simple stand characteristics.

Maier, Brian; Ottmar, Roger; Wright, Clint

2004-12-28T23:59:59.000Z

137

SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT  

SciTech Connect

A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Noteworthy achievements six months into the extended life of this cooperative agreement include: (1) Progress on the vertical line array (VLA) of sensors: Analysis and repair attempts of the VLA used in the deep water deployment during October 2003 have been completed; Definition of an interface protocol for the VLA DATS to the SFO has been established; Design modifications to allow integration of the VLA to the SFO have been made; Experience gained in the deployments of the first VLA is being applied to the design of the next VLAs; One of the two planned new VLAs being modified to serve as an Oceanographic Line Array (OLA). (2) Progress on the Sea Floor Probe: The decision to replace the Sea Floor Probe technology with the borehole emplacement of a geophysical array was reversed due to the 1300m water depth at the JIP selected borehole site. The SFP concept has been revisited as a deployment technique for the subsea floor array; The SFP has been redesigned to include gravity driven emplacement of an array up to 10m into the shallow subsurface of the sea floor. (3) Progress on the Acoustic Systems for Monitoring Gas Hydrates: Video recordings of bubbles emitted from a seep in Mississippi Canyon have been analyzed for effects of currents and temperature changes; Several acoustic monitoring system concepts have been evaluated for their appropriateness to MC118, i.e., on the deep sea floor; A mock-up system was built but was rejected as too impractical for deployment on the sea floor. (4) Progress on the Electromagnetic Bubble Detector and Counter: The initial Inductive Conductivity Cell has been constructed from components acquired during the previous reporting period; Laboratory tests involving measuring bubble volume as a component of conductivity have been performed; The laboratory tests were performed in a closed system, under controlled conditions; the relationship between voltage and bubble volume appears to be linear. (5) Progress on the Mid-Infrared Sensor for Continuous Methane Monitoring: Designs and construction schematics for all electronic mounting pieces and an electronics system baseplate were finalized after extensive modeling to facilitate the successful fabrication and implementation of electronic components into the deep-sea, glass instrument housing; Construction schematics and fabrication of an electronics system baseplate have been completed with successful integration of all currently fabricated electronic mounting pieces; Modeling and design of an optics platform complementary to the constructed electronics platform for successful incorporation into ''sphereIR'' has commenced; A second generation chemometric data evaluation software package for evaluating complex spectra including corrections for baseline drifts and spectral anomalies resulting from matrix substances has been developed and will be incorporated into an optimized ''deepSniff'' program upon c

Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

2005-09-01T23:59:59.000Z

138

Thermal Behavior of Floor Tubes in a Kraft Recovery Boiler  

SciTech Connect

The temperatures of floor tubes in a slope-floored black liquor recovery boiler were measured using an array of thermocouples located on the tube crowns. It was found that sudden, short duration temperature increases occurred with a frequency that increased with distance from the spout wall. To determine if the temperature pulses were associated with material falling from the convective section of the boiler, the pattern of sootblower operation was recorded and compared with the pattern of temperature pulses. During the period from September, 1998, through February, 1999, it was found that more than 2/3 of the temperature pulses occurred during the time when one of the fast eight sootblowers, which are directed at the back of the screen tubes and the leading edge of the first superheater bank, was operating.

Barker, R.E.; Choudhury, K.A.; Gorog, J.P.; Hall, L.M.; Keiser, J.R.; Sarma, G.B.

1999-09-12T23:59:59.000Z

139

Accelerated Wear Tests on Common Floor-covering Materials.  

E-Print Network (OSTI)

materials indicated there are variations in the changes of appearance and wear in these materials. Solid sheet vinyls and rubber tiles showed significantly less wear than asphalt tiles, vinyl- asbestos tiles, linoleums and cork. Asphalt tiles showed... in home installations. Six common floor covering materials-solid .sheet vinyls, rubber tiles, vinyl-asbestos tiles, J linoleums, corks and asphalt tiles-were used to construct 63 test specimens 2 x 2 feet in size. 1 T'ariations in specimens were...

Stewart, B. R.; Kunze, O. R.; Hobgood, Price.

1958-01-01T23:59:59.000Z

140

Property:Building/FloorAreaTotal | Open Energy Information  

Open Energy Info (EERE)

FloorAreaTotal FloorAreaTotal Jump to: navigation, search This is a property of type Number. Total Pages using the property "Building/FloorAreaTotal" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 19,657 + Sweden Building 05K0002 + 7,160 + Sweden Building 05K0003 + 4,454 + Sweden Building 05K0004 + 25,650 + Sweden Building 05K0005 + 2,260 + Sweden Building 05K0006 + 14,348 + Sweden Building 05K0007 + 24,155 + Sweden Building 05K0008 + 7,800 + Sweden Building 05K0009 + 34,755 + Sweden Building 05K0010 + 437 + Sweden Building 05K0011 + 15,300 + Sweden Building 05K0012 + 22,565 + Sweden Building 05K0013 + 19,551 + Sweden Building 05K0014 + 1,338.3 + Sweden Building 05K0015 + 1,550 + Sweden Building 05K0016 + 2,546 +

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Refinishing contamination floors in Spent Nuclear Fuels storage basins  

SciTech Connect

The floors of the K Basins at the Hanford Site are refinished to make decontamination easier if spills occur as the spent nuclear fuel (SNF) is being unloaded from the basins for shipment to dry storage. Without removing the contaminated existing coating, the basin floors are to be coated with an epoxy coating material selected on the basis of the results of field tests of several paint products. The floor refinishing activities must be reviewed by a management review board to ensure that work can be performed in a controlled manner. Major documents prepared for management board review include a report on maintaining radiation exposure as low as reasonably achievable, a waste management plan, and reports on hazard classification and unreviewed safety questions. To protect personnel working in the radiation zone, Operational Health Physics prescribed the required minimum protective methods and devices in the radiological work permit. Also, industrial hygiene safety must be analyzed to establish respirator requirements for persons working in the basins. The procedure and requirements for the refinishing work are detailed in a work package approved by all safety engineers. After the refinishing work is completed, waste materials generated from the refinishing work must be disposed of according to the waste management plan.

Huang, F.F.; Moore, F.W.

1997-07-11T23:59:59.000Z

142

SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT  

SciTech Connect

A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has already succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to innovate research methods and construct necessary instrumentation. As funding for this project, scheduled to commence December 1, 2002, had only been in place for less than half of the reporting period, project progress has been less than for other reporting periods. Nevertheless, significant progress has been made and several cruises are planned for the summer/fall of 2003 to test equipment, techniques and compatibility of systems. En route to reaching the primary goal of the Consortium, the establishment of a monitoring station on the sea floor, the following achievements have been made: (1) Progress on the vertical line array (VLA) of sensors: Software and hardware upgrades to the data logger for the prototype vertical line array, including enhanced programmable gains, increased sampling rates, improved surface communications, Cabling upgrade to allow installation of positioning sensors, Incorporation of capability to map the bottom location of the VLA, Improvements in timing issues for data recording. (2) Sea Floor Probe: The Sea Floor Probe and its delivery system, the Multipurpose sled have been completed; The probe has been modified to penetrate the <1m blanket of hemipelagic ooze at the water/sea floor interface to provide the necessary coupling of the accelerometer with the denser underlying sediments. (3) Electromagnetic bubble detector and counter: Initial tests performed with standard conductivity sensors detected nonconductive objects as small as .6mm, a very encouraging result, Components for the prototype are being assembled, including a dedicated microcomputer to control power, readout and logging of the data, all at an acceptable speed. (4) Acoustic Systems for Monitoring Gas Hydrates: Video recordings of bubbles emitted from a seep in Mississippi Canyon have been made from a submersible dive and the bubbles analyzed with respect to their size, number, and rise rate; these measurements will be used to determine the parameters to build the system capable of measuring gas escaping at the site of the monitoring station; A scattering system and bubble-producing device, being assembled at USM, will be tested in the next two months, and the results compared to a physical scattering model. (5) Mid-Infrared Sensor for Continuous Methane Monitoring: Progress has been made toward minimizing system maintenance through increased capacity and operational longevity, Miniaturization of many components of the sensor systems has been completed, A software package has been designed especially for the MIR sensor data evaluation, Custom electronics have been developed that reduce power consumption and, therefore, increase the length of time the system can remain operational. (6) Seismo-acoustic characterization of sea floor properties and processes at the hydrate monitoring station. (7) Adaptation of the acoustic-logging device, developed as part of the European Union-funded research project, Sub-Gate, for monitoring temporal variations in seabe

Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

2004-03-01T23:59:59.000Z

143

Simplified Modeling of Radiant Fields in Heterogeneous Photoreactors. 2. Limiting “Two-Flux” Model for the Case of Reflectance Greater Than Zero  

Science Journals Connector (OSTI)

Simplified Modeling of Radiant Fields in Heterogeneous Photoreactors. 2. Limiting “Two-Flux” Model for the Case of Reflectance Greater Than Zero ... This model thus belongs to the class of the “two-flux models” (Özisik, 1973) recently employed for heterogeneous photochemical reactor modeling purposes (Maruyama and Nishimoto, 1992). ...

Alberto Brucato; Lucio Rizzuti

1997-11-03T23:59:59.000Z

144

Development of a Transient Heat and Mass Transfer Model of Residential Attics to Predict Energy Savings Produced by the Use of Radiant Barriers  

E-Print Network (OSTI)

A transient heat and mass transfer model was developed to predict ceiling heat gain/loss through the attic space in residences and to accurately estimate savings in cooling and heating loads produced by the use of radiant barriers. The model...

Medina, M. A.

145

DOE Solar Decathlon: Santa Clara University  

NLE Websites -- All DOE Office Websites (Extended Search)

Santa Clara University Santa Clara University Radiant House sd13.scu.edu Radiant House is driven by three E's: efficiency, economics, and elegance. The house incorporates bamboo and takes it to a new level by using the sustainable material for structural wall and joist systems. Radiant House is an elegant, adaptable, and affordable house with a versatile great room, a large deck and patio area, and clean separation between private and public spaces. Design Philosophy Radiant House was guided by the belief that sustainable living can be affordable, appealing, and accessible to everyone. With an open floor plan and ramps leading to and from the house, Radiant House is fully accessible and features spacious rooms and an adaptable floor plan and furnishings. Features A structural wall and joist system is composed of a blend of

146

THERMAL EVALUATION OF CONTAMINATED LIQUID ONTO CELL FLOORS  

SciTech Connect

For the Salt Disposition Integration Project (SDIP), postulated events in the new Salt Waste Processing Facility (SWPF) can result in spilling liquids that contain Cs-137 and organics onto cell floors. The parameters of concern are the maximum temperature of the fluid following a spill and the time required for the maximum fluid temperature to be reached. Control volume models of the various process cells have been developed using standard conduction and natural convection relationships. The calculations are performed using the Mathcad modeling software. The results are being used in Consolidated Hazards Analysis Planning (CHAP) to determine the controls that may be needed to mitigate the potential impact of liquids containing Cs-137 and flammable organics that spill onto cell floors. Model development techniques and the ease of making model changes within the Mathcad environment are discussed. The results indicate that certain fluid spills result in overheating of the fluid, but the times to reach steady-state are several hundred hours. The long times allow time for spill clean up without the use of expensive mitigation controls.

(NOEMAIL), J

2009-05-04T23:59:59.000Z

147

Analysis of composite tube cracking in recovery boiler floors  

SciTech Connect

Cracking of co-extruded (generally identified as composite) floor tubes in kraft black liquor recovery boilers was first observed in Scandinavia, but this problem has now been found in many North American boilers. In most cases, cracking in the outer 304L stainless steel has not progressed into the carbon steel, but the potential for such crack propagation is a cause of concern. A multidimensional study has been initiated to characterize the cracking seen in composite floor tubes, to measure the residual stresses resulting from composite tube fabrication, and to predict the stresses in tubes under operating conditions. The characterization studies include review of available reports and documents on composite tube cracking, metallographic examination of a substantial number of cracked tubes, and evaluation of the dislocation structure in cracked tubes. Neutron and X-ray diffraction are being used to determine the residual stresses in composite tubes from two major manufacturers, and finite element analysis is being used to predict the stresses in the tubes during normal operation and under conditions where thermal fluctuations occur.

Keiser, J.R.; Taljat, B.; Wang, X.L.; Maziasz, P.J.; Hubbard, C.R.; Swindeman, R.W. [Oak Ridge National Lab., TN (United States); Singbeil, D.L.; Prescott, R. [Pulp and Paper Research Inst. of Canada, Vancouver, British Columbia (Canada)

1996-08-01T23:59:59.000Z

148

Efficient Formulations for the Multi-Floor Facility Layout Problem with ...  

E-Print Network (OSTI)

Feb 22, 2007 ... block diagram shows the location and dimensions of the building and .... where the material handling transportation between floors is executed ...

Marc Goetschalckx and Takashi Irohara

2007-02-22T23:59:59.000Z

149

Efficient Formulations for the Multi-Floor Facility Layout Problem with ...  

E-Print Network (OSTI)

Feb 28, 2007 ... Abstract: The block layout problem for a multi-floor facility is an important sub ... Category 2: Applications -- OR and Management Sciences ...

Marc Goetschalckx

2007-02-28T23:59:59.000Z

150

Statistical Analysis of Tank 5 Floor Sample Results  

SciTech Connect

Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, and the radionuclide1, elemental, and chemical concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements above their MDCs. The identification of distributions and the selection of UCL95 procedures generally followed the protocol in Singh, Armbya, and Singh [2010]. When all of an analyte's measurements lie below their MDCs, only a summary of the MDCs can be provided. The measurement results reported by SRNL are listed, and the results of this analysis are reported. The data were generally found to follow a normal distribution, and to be homogenous across composite samples.

Shine, E. P.

2013-01-31T23:59:59.000Z

151

Statistical Analysis Of Tank 5 Floor Sample Results  

SciTech Connect

Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, and the radionuclide, elemental, and chemical concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements above their MDCs. The identification of distributions and the selection of UCL95 procedures generally followed the protocol in Singh, Armbya, and Singh [2010]. When all of an analyte's measurements lie below their MDCs, only a summary of the MDCs can be provided. The measurement results reported by SRNL are listed in Appendix A, and the results of this analysis are reported in Appendix B. The data were generally found to follow a normal distribution, and to be homogenous across composite samples.

Shine, E. P.

2012-08-01T23:59:59.000Z

152

STATISTICAL ANALYSIS OF TANK 5 FLOOR SAMPLE RESULTS  

SciTech Connect

Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, radionuclide, inorganic, and anion concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements above their MDCs. The identification of distributions and the selection of UCL95 procedures generally followed the protocol in Singh, Armbya, and Singh [2010]. When all of an analyte's measurements lie below their MDCs, only a summary of the MDCs can be provided. The measurement results reported by SRNL are listed in Appendix A, and the results of this analysis are reported in Appendix B. The data were generally found to follow a normal distribution, and to be homogeneous across composite samples.

Shine, E.

2012-03-14T23:59:59.000Z

153

Study of the Applications of the Radiant Cooling Panel in Museum Showcases  

E-Print Network (OSTI)

, and testing of environment control system of showcases in museum [1~3]. This paper reviewed the recent researches and developments systematically, and found that the interior temperature in conventional showcase is controlled by means of centralized air...-conditioning system, which supplied conditioned air with air duct [4~6]. However, this conventional system can?t maintain the temperature at a required level. The temperature varies continually owing to unstable operation, even stop sometimes for problems...

Yu, L.; Hou, H.; Wan, X.; Chen, H.

2006-01-01T23:59:59.000Z

154

The Water Wall: A Passive Solar Collection and Thermal Storage Device for Supplementary Radiant Heating.  

E-Print Network (OSTI)

??Through the implementation of passive solar building systems, suburbia could take a fresh new step forward toward a progressively more sustainable direction. Making passive solar… (more)

Noseck, Rhett Roman

2013-01-01T23:59:59.000Z

155

This bright top floor accommodation comprises: -hall with shelved storage cupboard  

E-Print Network (OSTI)

This bright top floor accommodation comprises: - hall with shelved storage cupboard - fully oak flooring in the living/dining room and varnished floorboards in the hall and double bedroom regarded restaurants and a Waitrose supermarket. Recreational facilities can be found at Warrender Swimming

Edinburgh, University of

156

Property:Building/FloorAreaUnheatedRentedPremises | Open Energy Information  

Open Energy Info (EERE)

FloorAreaUnheatedRentedPremises FloorAreaUnheatedRentedPremises Jump to: navigation, search This is a property of type Number. Floor area for Unheated but rented-out premises (garages) < 10 °C Pages using the property "Building/FloorAreaUnheatedRentedPremises" Showing 6 pages using this property. S Sweden Building 05K0021 + 700 + Sweden Building 05K0050 + 760 + Sweden Building 05K0058 + 1,200 + Sweden Building 05K0080 + 2,000 + Sweden Building 05K0081 + 700 + Sweden Building 05K0102 + 234 + Retrieved from "http://en.openei.org/w/index.php?title=Property:Building/FloorAreaUnheatedRentedPremises&oldid=285964#SMWResults" What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load)

157

SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT  

SciTech Connect

A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to innovate research methods and construct necessary instrumentation. A year into the life of this cooperative agreement, we note the following achievements: (1) Progress on the vertical line array (VLA) of sensors: (A) Software and hardware upgrades to the data logger for the prototype vertical line array, including enhanced programmable gains, increased sampling rates, improved surface communications, (B) Cabling upgrade to allow installation of positioning sensors, (C) Adaptation of SDI's Angulate program to use acoustic slant ranges and DGPS data to compute and map the bottom location of the vertical array, (D) Progress in T''0'' delay and timing issues for improved control in data recording, (E) Successful deployment and recovery of the VLA twice during an October, 2003 cruise, once in 830m water, once in 1305m water, (F) Data collection and recovery from the DATS data logger, (G) Sufficient energy supply and normal functioning of the pressure compensated battery even following recharge after the first deployment, (H) Survival of the acoustic modem following both deployments though it was found to have developed a slow leak through the transducer following the second deployment due, presumably, to deployment in excess of 300m beyond its rating. (2) Progress on the Sea Floor Probe: (A) The Sea Floor Probe and its delivery system, the Multipurpose sled have been completed, (B) The probe has been modified to penetrate the <1m blanket of hemipelagic ooze at the water/sea floor interface to provide the necessary coupling of the accelerometer with the denser underlying sediments, (C) The MPS has been adapted to serve as an energy source for both p- and s-wave studies at the station as well as to deploy the horizontal line arrays and the SFP. (3) Progress on the Electromagnetic Bubble Detector and Counter: (A) Components for the prototype have been assembled, including a dedicated microcomputer to control power, readout and logging of the data, all at an acceptable speed, (B) The prototype has been constructed and preliminary data collected, (C) The construction of the field system is underway. (4) Progress on the Acoustic Systems for Monitoring Gas Hydrates: (A) Video recordings of bubbles emitted from a seep in Mississippi Canyon have been made from a submersible dive and the bubbles analyzed with respect to their size, number, and rise rate. These measurements have been used to determine the parameters to build the system capable of measuring gas escaping at the site of the monitoring station, (B) Laboratory tests performed using the project prototype have produced a conductivity data set that is being used to refine parameters of the field model. (5) Progress on the Mid-Infrared Sensor for Continuous Methane Monitoring: (A) Preliminary designs of mounting pieces for electrical components of ''sphereIR'' have been completed using AutoCAD software, (B) The preliminary design of an electronics baseplate has been completed and aided in the optimization of

Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

2005-08-01T23:59:59.000Z

158

SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT  

SciTech Connect

A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Noteworthy achievements one year into the extended life of this cooperative agreement include: (1) Progress on the vertical line array (VLA) of sensors: (1a) Repair attempts of the VLA cable damaged in the October >1000m water depth deployment failed; a new design has been tested successfully. (1b) The acoustic modem damaged in the October deployment was repaired successfully. (1c) Additional acoustic modems with greater depth rating and the appropriate surface communications units have been purchased. (1d) The VLA computer system is being modified for real time communications to the surface vessel using radio telemetry and fiber optic cable. (1e) Positioning sensors--including compass and tilt sensors--were completed and tested. (1f) One of the VLAs has been redesigned to collect near sea floor geochemical data. (2) Progress on the Sea Floor Probe: (2a) With the Consortium's decision to divorce its activities from those of the Joint Industries Program (JIP), due to the JIP's selection of a site in 1300m of water, the Sea Floor Probe (SFP) system was revived as a means to emplace arrays in the shallow subsurface until arrangements can be made for boreholes at >1000m water depth. (2b) The SFP penetrometer has been designed and construction begun. (2c) The SFP geophysical and pore-fluid probes have been designed. (3) Progress on the Acoustic Systems for Monitoring Gas Hydrates: (3a) Video recordings of bubbles emitted from a seep in Mississippi Canyon have been analyzed for effects of currents and temperature changes. (3b) Several acoustic monitoring system concepts have been evaluated for their appropriateness to MC118, i.e., on the deep sea floor. (3c) A mock-up system was built but was rejected as too impractical for deployment on the sea floor. (4) Progress on the Electromagnetic Bubble Detector and Counter: (4a) Laboratory tests were performed using bubbles of different sizes in waters of different salinities to test the sensitivity of the. Differences were detected satisfactorily. (4b) The system was field tested, first at the dock and then at the shallow water test site at Cape Lookout Bight where methane bubbles from the sea floor, naturally, in 10m water depth. The system successfully detected peaks in bubbling as spike decreases in conductivity. (5) Progress on the Mid-Infrared Sensor for Continuous Methane Monitoring: (5a) Modeling and design of an optics platform complementary to the constructed electronics platform for successful incorporation into ''sphereIR'' continues. AutoCAD design and manual construction of mounting pieces for major optical components have been completed. (5b) Initial design concepts for IR-ATR sensor probe geometries have been established and evaluated. Initial evaluations of a horizontal ATR (HATR) sensing probe with fiber optic guiding light have been performed and validate the design concept as a potentially viable deep sea sensing pr

Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

2005-11-01T23:59:59.000Z

159

Thermal comfort, skin temperature distribution, and sensible heat loss distribution in the sitting posture in various asymmetric radiant fields  

Science Journals Connector (OSTI)

This study aimed at investigating the thermal comfort for the whole body as well as for certain local areas, skin temperatures, and sensible heat losses in various asymmetric radiant fields. Human subject experiments were conducted to assess the overall comfort sensation and local discomfort, and local skin temperatures were measured. Through thermal manikin experiments, we discovered a new method for the precise measurement of the local sensible heat loss in nonuniform thermal environments. The local sensible heat losses were measured by the use of a thermal manikin that had the same local skin temperatures as the human subjects. The experimental conditions consisted of the anterior–posterior, right–left, and up–down asymmetric thermal environments created by radiation panels. A total of 35 thermal environmental conditions were created ranging from 25.5 to 30.5 °C for air temperature, from 11.5 to 44.5 °C for surface temperature of radiation panels, from 40% RH to 50% RH for humidity, and less than 0.05 m/s for inlet air velocity to the climatic chamber. The local skin temperature changed depending on the environmental thermal nonuniformity, even if the mean skin temperature remained almost the same. It is essential to use the skin temperature distribution as well as mean skin temperature for expressing thermal comfort in nonuniform environments. The local sensible heat loss changed depending on the environmental thermal nonuniformity, even if the mean sensible heat loss remained almost the same. The relationship between the local skin temperature and local sensible heat loss cannot be depicted by a simple line; instead, it varies depending on the environmental thermal nonuniformity. The local heat discomfort in the head area was dependent on both the local skin temperature and local sensible heat loss. However, the local cold discomfort in the foot area was related only to the local skin temperature.

Tomonori Sakoi; Kazuyo Tsuzuki; Shinsuke Kato; Ryozo Ooka; Doosam Song; Shengwei Zhu

2007-01-01T23:59:59.000Z

160

Solar system having improved heliostat and sensor mountings  

SciTech Connect

This specification discloses an improvement in a solar system having one or more collectors for receiving and using radiant energy from the sun and at least one and preferably a plurality of respective reflector means for reflecting the radiant energy onto the collectors. The improvement is characterized by having each reflector in the form of a heliostat that can be moved to maximize the radiant energy reflected onto its collector, driving motor for so moving each heliostat; firmly anchored support structure carrying each heliostat; and sensor connected by suitable controls with each drive motor for so moving each heliostat; the respective sensor being mounted on the same support structure as the heliostat and aligned in a straight line from the heliostat to its collector. With this construction, the sensor does not require an expensive and firmly anchored separate support structure to prevent receiving small surface movements different from those received by the heliostat.

Blake, F.A.; Northrup, L.L.

1980-10-14T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Property:Building/FloorAreaHealthServices24hr | Open Energy Informatio...  

Open Energy Info (EERE)

Jump to: navigation, search This is a property of type Number. Floor area for 24-hour health services Retrieved from "http:en.openei.orgwindex.php?titleProperty:Building...

162

Cornell University Hot Water Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Hot Water System Hot Water System The production and delivery of hot water in the CUSD home is technologically advanced, economical, and simple. Hot water is produced primarily by the evacuated solar thermal tube collectors on the roof of the house. The solar thermal tube array was sized to take care of the majority of our heating and hot water needs throughout the course of the year in the Washington, DC climate. The solar thermal tube array also provides heating to the radiant floor. The hot water and radiant floor systems are tied independently to the solar thermal tube array, preventing the radiant floor from robbing the water heater of much needed thermal energy. In case the solar thermal tubes are not able to provide hot water to our system, the hot water tank contains an electric heating

163

Building America Technlogy Solutions for New and Existing Homes: Interior Foundation Insulation Upgrade – Madison Residence (Fact Sheet)  

Energy.gov (U.S. Department of Energy (DOE))

This basement insulation project included a dimple map conveying inbound moisture to a draintile, airtight spray polyurethane foam wall and floor insulation, and radiant floor heat installation.

164

Laser multiplexing system  

DOE Patents (OSTI)

A plurality of copper lasers, as radiant power sources, emits a beam of power carrying radiation. A plurality of fiber injection assemblies receives power from the plurality of copper lasers and injects such power into a plurality of fibers for individually transmitting the received power to a plurality of power-receiving devices. The power-transmitting fibers of the system are so arranged that power is delivered therethrough to each of the power-receiving devices such that, even if a few of the radiant power sources and/or fibers fail, the power supply to any of the power receiving devices will not completely drop to zero but will drop by the same proportionate amount.

Johnson, Steve A. (Tracy, CA); English, Jr., Ronald Edward (Tracy, CA); White, Ronald K. (Livermore, CA)

2001-01-01T23:59:59.000Z

165

Inspection of the objects on the sea floor by using 14 MeV tagged neutrons  

SciTech Connect

Variety of objects found on the sea floor needs to be inspected for the presence of materials which represent the threat to the environment and to the safety of humans. We have demonstrated that the sealed tube 14 MeV neutron generator with the detection of associated alpha particles can be used underwater when mounted inside ROV equipped with the hydraulic legs and variety of sensors for the inspection of such objects for the presence of threat materials. Such a system is performing the measurement by using the NaI gamma detector and an API-120 neutron generator which could be rotated in order to maximize the inspected target volume. The neutron beam intensity during the 10-30 min. measurements is usually 1 x 10{sup 7} n/s in 4{pi}. In this report the experimental results for some of commonly found objects containing TNT explosive or its simulant are presented. The measured gamma spectra are dominant by C, O and Fe peaks enabling the determination of the presence of explosives inside the ammunition shell. Parameters influencing the C/O ratio are discussed in some details. (authors)

Valkovic, V. [A.C.T.d.o.o., Prilesje 4, Zagreb (Croatia); Sudac, D.; Obhodas, J. [Dept. of Experimental Physics, Inst. Ruder Boskovic, Zagreb (Croatia); Matika, D. [Inst. for Researches and Development of Defense Systems, Zagreb (Croatia); Kollar, R. [A.C.T.d.o.o., Prilesje 4, Zagreb (Croatia); Nad, K.; Orlic, Z. [Dept. of Experimental Physics, Inst. Ruder Boskovic, Zagreb (Croatia)

2011-07-01T23:59:59.000Z

166

Dark Matter vs. Neutrinos: The effect of astrophysical uncertainties and timing information on the neutrino floor  

E-Print Network (OSTI)

Future multi-tonne Direct Detection experiments will be sensitive to solar neutrino induced nuclear recoils which form an irreducible background to light Dark Matter searches. Indeed for masses around 6 GeV the spectra of neutrinos and Dark Matter are so similar that experiments will run into a neutrino floor, for which sensitivity increases only marginally with exposure past a certain cross section. In this work we show that this floor can be overcome using the different annual modulation expected from solar neutrinos and Dark Matter. Specifically for cross sections below the neutrino floor the DM signal is observable through a phase shift and a smaller amplitude for the time-dependent event rate. This allows the exclusion power to be improved by up to an order of magnitude for large exposures. In addition we demonstrate that the neutrino floor exists over a wider mass range than has been previously shown, since the large uncertainties in the Dark Matter velocity distribution make the signal spectrum harder to distinguish from the neutrino background. However for most velocity distributions the neutrino floor can still be surpassed using timing information, though certain velocity streams may prove problematic.

Jonathan H. Davis

2014-12-03T23:59:59.000Z

167

Report on Analysis of Forest Floor Bulk Density and Depth at the Savannah River Site.  

SciTech Connect

The forest floor data from the Savannah River Site consists of two layers, the litter layer and the duff layer. The purpose for the study was to determine bulk density conversion factors to convert litter and duff depth values in inches to forest floor fuel values in tons per acre. The primary objective was to collect litter and duff samples to adequately characterize forest floor depth and bulk density for combinations of 4 common forest types (loblolly/slash pine, longleaf pine, pine and hardwood mix, upland hardwood), 3 age classes (5-20, 20-40, 40+ years old) and 3 categories of burning history (0-3, 3-10, 10+ years since last burn).

Bernard R. Parresol

2005-10-01T23:59:59.000Z

168

WhiteCap DOE/ERIP progress report, October--December 1996  

SciTech Connect

This progress report describes work done October through December 1996 for the WhiteCap system. The work included installation and commissioning of the large WhiteCap system at the Common House, radiant cooling components installation in the floor of the Southwest House, preparation of an operations and maintenance manual, and commissioning of a monitoring system.

NONE

1997-01-10T23:59:59.000Z

169

RADIOGRAPHIC IMAGING BELOW A VOLCANIC CRATER FLOOR WITH COSMIC-RAY MUONS  

E-Print Network (OSTI)

horizontally-arriving cosmic ray muon with energy of 1 TeV can penetrate 2.6 km of water. Thus, cosmic-ray muon that uncertainty on the shape and amplitude of the energy spectrum of the muon source is within a few percentRADIOGRAPHIC IMAGING BELOW A VOLCANIC CRATER FLOOR WITH COSMIC-RAY MUONS HIROYUKI K.M. TANAKA

Aoki, Yosuke

170

Particle resuspension from indoor flooring materials James H. Lohaus, Atila Novoselac and Jeffrey A. Siegel*  

E-Print Network (OSTI)

Particle resuspension from indoor flooring materials James H. Lohaus, Atila Novoselac and Jeffrey A@mail.utexas.edu Keywords: Fluid dynamics, Indoor surfaces, Particle experiments Introduction Particle resuspension from for supermicron particles. Resuspension is usually reported either as a critical velocity, the velocity at which

Siegel, Jeffrey

171

Support Vector Networks for Prediction of Floor Pressures in Shallow Cavity Flows  

E-Print Network (OSTI)

to collect a set of data, which is in the form of pressure readings from particular points in the test measurement at the cavity floor. The SVM based model is built for a very limited amount of training data indicate that the SVM based model is capable of matching the experimental data satisfactorily over

Efe, Mehmet Ã?nder

172

Marketing & Communications Office 21 N. Park Street, 7th floor, 262-2723  

E-Print Network (OSTI)

Marketing & Communications Office 21 N. Park Street, 7th floor, 262-2723 Fax: 265-4555 JOB REQUEST for Publications/Design form. rev. 4/09 Address/ phone Due Date Article (2 page, 500+ words) Marketing Copy (ad to (if different than client): Web copy Other Market Research Marketing Plan Development Photography

Sheridan, Jennifer

173

Analysis of sludge from K East basin floor and weasel pit  

SciTech Connect

Sludge samples from the floor of the Hanford K East Basin fuel storage pool have been retrieved and analyzed. Both chemical and physical properties have been determined. The results are to be used to determine the disposition of the bulk of the sludge and possibly assess the impact of residual sludge on dry storage of the associated intact metallic uranium fuel elements.

Makenas, B.J., Westinghouse Hanford

1996-05-04T23:59:59.000Z

174

PRINCETON UNIVERSITY Office of the General Counsel New South, Fourth Floor  

E-Print Network (OSTI)

PRINCETON UNIVERSITY Office of the General Counsel New South, Fourth Floor (609) 258-2500 To as interpreted by the U.S. Department of Education's Office for Civil Rights (OCR). In the event you believe with the authority to interpret and enforce Title IX. In this capacity, OCR is given substantial deference by courts

Singh, Jaswinder Pal

175

Category Measure Minimum Efficiency / Certification  

E-Print Network (OSTI)

and cooling (floor, wall, and ceiling) Radiant systems must be powered by a heat pump (electric or gas-fired, or ground-source), efficient gas boiler, or solar system (not by electric resistance) $4000-$20000 none sealing $300-$1200 Not clear if Xcel insulation/air sealing rebate applies here Energy or heat recovery

Kammen, Daniel M.

176

Building HVAC Requirements Overview Page 4-1 4 Building HVAC Requirements  

E-Print Network (OSTI)

heating, radiant floor systems, evaporative cooling, gas cooling, ground-source heat pumps, and wood space requirements for additions to existing dwellings and for alterations to existing heating and cooling systems packages. Package C permits electric resistance space heating, but requires significantly greater

177

A flexible control system for flexible manufacturing systems  

E-Print Network (OSTI)

in developing nations. The current efforts in automation are identified as flexible manufacturing systems (FMSs) if they are limited to the shop floor or computer integrated manufacturing (CIM) if they include front office functions including computer aided... Unfortunately, CIM systems are ?virtually out of reach of most of the small companies that could most benefit from CIM,? because no commercial software is available to perform integrated control over the individual shop floor components (Smith and Joshi, 1995...

Scott, Wesley Dane

2004-09-30T23:59:59.000Z

178

Cold Vacuum Drying facility effluent drains system design description (SYS 18)  

SciTech Connect

The Cold Vacuum Drying (CVD) Facility provides required process systems, supporting equipment, and facilities needed for the Spent Nuclear Fuel (SNF) mission. This system design description (SDD) addresses the effluent drain system (EFS), which supports removal of water from the process bay floors. The discussion that follows is limited to piping, valves, components, and the process bay floor drain retention basin.

TRAN, Y.S.

2000-05-11T23:59:59.000Z

179

Pore-Level Modeling of Carbon Dioxide Infiltrating the Ocean Floor  

NLE Websites -- All DOE Office Websites (Extended Search)

Infiltrating the Ocean Floor Infiltrating the Ocean Floor Grant S. Bromhal, Duane H. Smith, US DOE, National Energy Technology Laboratory, Morgantown, WV 26507-0880; M. Ferer, Department of Physics, West Virginia University, Morgantown, WV 26506-6315 Ocean sequestration of carbon dioxide is considered to be a potentially important method of reducing greenhouse gas emissions (US DOE, 1999). Oceans are currently the largest atmospheric carbon dioxide sink; and certainly, enough storage capacity exists in the oceans to hold all of the CO 2 that we can emit for many years. Additionally, technologies exist that allow us to pump liquid CO 2 into the oceans at depths between one and two kilometers for extended periods of time and five times that deep for shorter durations. The biggest unknown in the ocean sequestration process, however, is the fate and

180

Contribution of floor treatment characteristics to background noise levels in health care facilities, Part 1  

Science Journals Connector (OSTI)

Acoustical tests were conducted on five types of commercial-grade flooring to assess their potential contribution to noise generated within health care facilities outside of patient rooms. The floor types include sheet vinyl (with and without a 5 mm rubber backing) virgin rubber (with and without a 5 mm rubber backing) and a rubber-backed commercial grade carpet for comparison. The types of acoustical tests conducted were ISO-3741 compliant sound power level testing (using two source types: a tapping machine to simulate footfalls and a rolling hospital cart) and sound absorption testing as per ASTM-C423. Among the non-carpet samples the material type that produced the least sound power was determined to be the rubber-backed sheet vinyl. While both 5 mm-backed samples showed a significant difference compared to their un-backed counterparts with both source types the rubber-backed sheet vinyl performed slightly better than the rubber-backed virgin rubber in the higher frequency bands in both tests. The performance and suitability of these flooring materials in a health care facility compared to commercial carpeting will be discussed. [Work supported by Paul S. Veneklasen Research Foundation.

Adam L. Paul; David A. Arena; Eoin A. King

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Development of generic floor response spectra for equipment qualification for seismic loads  

SciTech Connect

A generic floor response spectra has been developed for use in the qualification of electrical and mechanical equipment in operating nuclear power plants. Actual PWR and BWR - Mark I structural models were used as representative of a class of structures. For each model, the stiffness properties were varied, with the same mass, so as to extend the fundamental base structure natural frequency from 2 cps to 36 cps. This resulted in fundamental mode coupled natural frequencies as low as 0.86 cps and as high as 30 cps. The characteristics of 1000 floor response spectra were studied to determine the generic spectra. A procedure for its application to any operating plant has been established. The procedure uses as much or as little information that currently exists at the plant relating to the question of equipment qualification. A generic floor response spectra is proposed for the top level of a generic structure. Reduction factors are applied to the peak acceleration for equipment at lower levels.

Curreri, J.R.; Costantino, C.J.

1984-10-01T23:59:59.000Z

182

Status Report on Studies of Recovery Boiler Composite Floor Tube Cracking  

SciTech Connect

Cracking of the stainless steel layer of co-extruded 304L stainless steel/SA210 Gd A 1 carbon steel black liquor recovery boiler floor tubes has been identified as one of the most serious material problems in the pulp and paper industry. A DOE-funded study was initiated in 1995 with the goal of determining the cause of and possible solutions to this cracking problem. These studies have characterized tube cracking as well as the chemical and thermal environment and stress state of floor tubes. Investigations of possible cracking mechanisms indicate that stress corrosion cracking rather than thermal fatigue is a more likely cause of crack initiation. The cracking mechanism appears to require the presence of hydrated sodium sulfide and is most likely active during shut-downs and/or start-ups. Based on these results and operating experience, certain alloys appear to be more resistant than others to cracking in the floor environment, and certain operating practices appear to significantly lessen the likelihood of cracking. This report is the latest in a series of progress reports presented on this project.

Eng, P.; Frederick, L.A.; Hoffmann, C.M.; Keiser, J.R.; Mahmood, J.; Maziasz, P.J.; Prescott, R.; Sarma, G.B.; Singbeil, D.L.; Singh, P.M.; Swindeman, R.W.; Wang, X.-L.

1999-09-12T23:59:59.000Z

183

Energy Efficiency Optimization of Joining Processes on Shop Floor and Process Chain Level  

Science Journals Connector (OSTI)

Abstract Research has shown that the energy demand for manufacturing processes is frequently dominated by secondary consumers, especially since these are often neither controlled nor accounted for by corresponding primary processes. Secondary consumers are often continuously operating on high load, independent of the supported core processes’ operational state – e.g. downtimes. This perception has lead to a methodical approach, calculating an energetic performance indicator that can be actively influenced by both, manufacturing and technology planning as well as production planning. The case presented focuses a joining application wherein the detailed analysis on the shop floor lead to approaches on process chain level.

Christian Mose; Nils Weinert

2014-01-01T23:59:59.000Z

184

Innovative accessible sunken floor systems for multi-story steel buildings  

E-Print Network (OSTI)

With the demands of telecommunications and computer equipment, building owners and designers are facing an increasingly difficult problem for wire management in today's electronic workplace. This thesis is to investigate ...

Kwan, Henry K

1987-01-01T23:59:59.000Z

185

Holocene valley-floor deposition and incision in a small drainage basin in western Colorado, USA  

Science Journals Connector (OSTI)

The valley floor of a 33.9 km2 watershed in western Colorado experienced gradual sedimentation from before ? 6765 to ? 500 cal yr BP followed by deep incision, renewed aggradation, and secondary incision. In contrast, at least four terraces and widespread cut-and-fill architecture in the valley floor downstream indicate multiple episodes of incision and deposition occurred during the same time interval. The upper valley fill history is atypical compared to other drainages in the Colorado Plateau. One possible reason for these differences is that a bedrock canyon between the upper and lower valley prevented headward erosion from reaching the upper valley fill. Another possibility is that widespread, sand-rich, clay-poor lithologies in the upper drainage limited surface runoff and generally favored alluviation, whereas more clay-rich lithologies in the lower drainage resulted in increased surface runoff and more frequent incision. Twenty-two dates from valley fill charcoal indicate an approximate forest fire recurrence interval of several hundred years, similar to that from other studies in juniper–piñon woodlands. Results show that closely spaced vertical sampling of alluvium in headwater valleys where linkages between hillslope processes and fluvial activity are relatively direct can provide insight about the role of fires in alluvial chronologies of semi-arid watersheds.

Lawrence S. Jones; Margaret Rosenburg; Maria del Mar Figueroa; Kathleen McKee; Ben Haravitch; Jenna Hunter

2010-01-01T23:59:59.000Z

186

Effects of lithospheric rigidity on ocean floor bathymetry and heat flow  

SciTech Connect

The observed quasi-rigid behaviour of surface plates in the course of their relative motion is a consequence of the high viscosity which obtains in the cold near surface region. By assigning a particular constant velocity as the upper boundary condition in a numerical model of mantle convection, we have investigated the effect of lithospheric rigidity on the variation of oceanic bathymetry and heat flow as a function of ocean floor age. Predicted variations of both bathymetry and heat flow at the surface of mantle wide convection cells which are partially heated from within, exhibit the same qualitative behaviour as data compiled for the major ocean basins. The bathymetry varies with distance x from the spreading centre initially as x/sup 1/2/ but subsequently flattens with respect to an x/sup 1/2/ reference curve whereas the heat flow closely follows an x-/sup 1/2/ decay over most of the convection cell. Consequently the viability of the mechanism for sea floor flattening proposed by Jarvis and Peltier (1980) is increased when a constant surface velocity, characteristic of rigid plates, is incorporated in the model. This model successfully predicts both that the bathymetry should flatten and that the heat flow should not.

Jarvis, G.T.; Peltier, W.R.

1981-08-01T23:59:59.000Z

187

Overview of the DOE studies of recovery boiler floor tube cracking  

SciTech Connect

Cracking of the stainless steel layer of coextruded 304L/SA210 recovery boiler floor tubes has been observed in an increasing number of black liquor recovery boilers. Because failure of such tubes is a serious safety concern as well as an economic issue, this project was initiated with the objective of identifying alternate materials or process changes that would prevent tube cracking. Tensile stresses are essential for the most likely failure mechanisms, i.e., fatigue or stress corrosion cracking, therefore stresses were measured at room temperature and modeling was used to predict stresses under operating conditions. Laboratory studies have identified conditions under which composite tubes crack due to thermal fatigue and stress corrosion. Floor tube temperature measurements have defined the magnitude and frequency of temperature fluctuations experienced by such tubes, and smelt corrosion studies have measured the degradation rate when molten smelt comes in contact with tubes. Based on these observations, certain materials appear more likely to resist cracking and certain process changes should help avoid conditions that cause composite tube cracking.

Keiser, J.R.; Taljat, B.; Wang, X.L. [and others

1998-03-01T23:59:59.000Z

188

STATE OF INDIANA OFFICE OF THE GOVERNOR State House, Second Floor  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

INDIANA INDIANA OFFICE OF THE GOVERNOR State House, Second Floor Indianapolis, Indiana 46204 Mitchell E. Daniels, Jr. Governor March 12,2009 The Honorable Steven Chu Secretary U.S. Department of Energy 1000 Independence Avenue, S. W Washington, D.C. 20585 Re: State Energy Program Assurances Dear Secretary Chu: As a condition of receiving our State's share of the $3.1 billion funding for the State Energy Program (SEP) under the American Recovery and Renewal Act of 2009 (H.R. I)(ARRA), I am providing the following assurances. I have requested our public utility commission (the Indiana Utility Regulatory Commission) to consider additional actions to promote energy efficiency, consistent with the federal statutory language contained in H.R. 1 and their obligations to

189

Report Period: EIA ID NUMBER: Instructions: (e.g., Street Address, Bldg, Floor, Suite)  

U.S. Energy Information Administration (EIA) Indexed Site

Report Period: Report Period: EIA ID NUMBER: Instructions: (e.g., Street Address, Bldg, Floor, Suite) Secure File Transfer option available at: (e.g., PO Box, RR) Electronic Transmission: The PC Electronic Data Reporting Option (PEDRO) is available. Zip Code: - If interested in software, call (202) 586-9659. Email form to: Fax form to: (202) 586-9772 - - Mail form to: Oil & Gas Survey - - U.S. Department of Energy Ben Franklin Station PO Box 279 Washington, DC 20044-0279 Questions? Call toll free: 1-800-638-8812 OOG.SURVEYS@eia.doe.gov Contact Name: Version No.: 2013.01 Date of this Report: Mo Day State: Year Phone No.: DOMESTIC CRUDE OIL FIRST PURCHASE REPORT Company Name: A completed form must be filed by the 30th calendar day following the end of the report

190

Construction of a global disaggregated dataset of building energy use and floor area in 2010  

Science Journals Connector (OSTI)

Abstract This paper presents the construction of a dataset of energy use in 2010 by buildings in 10 regions spanning the entire world, broken down by sector (residential and commercial), end use (space heating, space cooling, ventilation, water heating, lighting, cooking, and miscellaneous (mostly plug) loads) and energy source (fossil fuels, district heat, biofuels, solar and geothermal heat, and electricity). Combined with estimates of the residential and commercial floor area and of population in each region, this 4-dimensional disaggregation gives an estimate of building energy intensities (kW h/m2/yr) or per capita energy use for each end use/energy source combination in each sector and region. This dataset provides a starting point that can be used in scenarios of future building energy demand but also serves to highlight discrepancies, uncertainties, and areas where improved data collection is needed.

L.D. Danny Harvey; Katarina Korytarova; Oswaldo Lucon; Volha Roshchanka

2014-01-01T23:59:59.000Z

191

Basin-floor fans in the North Sea: Sequence stratigraphic models vs. sedimentary facies  

SciTech Connect

Examination of nearly 12,000 feet (3658m) of conventional core from Paleogene and Cretaceous deep-water sandstone reservoirs cored in 50 wells in 10 different areas or fields in the North Sea and adjacent regions reveals that these reservoirs are predominantly composed of mass-transport deposits, mainly sandy slumps and sandy debris flows. Sedimentary features indicating slump and debris-flow origin include sand units with sharp upper contacts; slump folds; discordant, steeply dipping layers (up to 60{degrees}); glide planes; shear zones; brecciated clasts; clastic injections; floating mudstone clasts; planar clast fabric; inverse grading of clasts; and moderate-to-high matrix content (5-30%). This model predicts that basin-floor fans are predominantly composed of sand-rich turbidites with laterally extensive, sheetlike geometries. However, calibration of sedimentary facies in our long (400-700 feet) cores with seismic and wire-line-log signatures through several of these basin-floor fans (including the Gryphon-Forth, Frigg, and Faeroe areas) shows that these features are actually composed almost exclusively of mass-transport deposits consisting mainly of slumps and debris flows. Distinguishing deposits of mass-transport processes, such as debris flows, from those of turbidity currents has important implications for predicting reservoir geometry. Debris flows, which have plastic flow rheology, can form discontinuous, disconnected sand bodies that are harder to delineate and less economical to develop than deposits of fluidal turbidity currents, which potentially produce more laterally continuous, interconnected sand bodies. Process sedimentological interpretation of conventional core is commonly critical for determining the true origin and distribution of reservoir sands.

Shanmugam, G.; Bloch, R.B. [Mobil Research and Development Corp., Dallas, TX (United States); Mitchell, S.M. [Mobil Exploration and Producing US, Inc., Dallas, TX (United States); Beamish, G.W.J.; Shields, K.E. [Mobil North Sea Ltd., London (United Kingdom); Hodgkinson, R.J.; Straume, T.; Syvertsen, S.E. [Mobil Exploration Norway, Inc., Stavanger (Norway); Damuth, J.E. [Univ. of Texas, Arlington, TX (United States)

1995-04-01T23:59:59.000Z

192

A Nontoxic System for 41.8°C Whole-Body Hyperthermia: Results of a Phase I Study Using a Radiant Heat Device  

Science Journals Connector (OSTI)

...metabolic rate, volume of distribution, and individual drug...the neck. Evaporative heat loss from the head was minimized...to prevent evaporative heat losses. Following this, the...8 C was equal to the heat losses from the covered patient...

H. Ian Robins; Warren H. Dennis; Alan J. Neville; Linda M. Shecterle; Patricia A. Martin; Jeffrey Grossman; Thomas E. Davis; Susan R. Neville; Wilma K. Gillis; and Ben F. Rusy

1985-08-01T23:59:59.000Z

193

Radiant cooling research scoping study  

E-Print Network (OSTI)

greenhouse gas emissions relative to a code-compliant design. Principal strategies included first optimizing building envelope and lighting

Moore, Timothy; Bauman, Fred; Huizenga, Charlie

2006-01-01T23:59:59.000Z

194

Radiant cooling research scoping study  

E-Print Network (OSTI)

or supply-water temperature control failure, most designscontrol is almost entirely independent of ventilation supply air temperature.

Moore, Timothy; Bauman, Fred; Huizenga, Charlie

2006-01-01T23:59:59.000Z

195

METHOD OF EVALUATING THE EFFICIENCY OF ANTICOCCIDIAL DRUGS IN FLOOR-PEN TRIALS WITH MULTIPLE IN-FEED INFECTION VERSUS  

E-Print Network (OSTI)

contrôler la contamination des animaux que par la méthode des « seeder birds » et l'anticoccidien a une of environmental contamina- tion. Cover (1970) considers that floor-pen expe- riments are essential because) ; these authors use either a direct contamina- tion by suspended « seeder birds », or an indi- rect contamination

Boyer, Edmond

196

PII S0016-7037(00)00511-1 Reaction of forest floor organic matter at goethite, birnessite and smectite surfaces  

E-Print Network (OSTI)

PII S0016-7037(00)00511-1 Reaction of forest floor organic matter at goethite, birnessite carbon (DOC) concentrations (0­140 g C m 3 ) for reaction with goethite ( -FeOOH), birnessite ( -MnO2 different NOM adsorption, fractionation and transformation patterns. Goethite exhibited a steep initial

Chorover, Jon

197

Alliance of Chicago Community Health Services, L3C 215 W. Ohio, 4th floor Chicago, IL 60654  

E-Print Network (OSTI)

Alliance of Chicago Community Health Services, L3C 215 W. Ohio, 4th floor Chicago, IL 60654 Phone at the Alliance of Chicago Community Health Services (Alliance). He/She is responsible for programming design life cycle for the Alliance EHR, which includes the following primary tasks: o Programming

Liblit, Ben

198

Hindawi Publishing Corporation 410 Park Avenue,15th Floor,#287 pmb,New York,NY 10022,USA  

E-Print Network (OSTI)

Corporation 410 Park Avenue,15th Floor,#287 pmb,New York,NY 10022,USA http. Bona USA J. R. Cannon USA S.-N. Chow USA B. S. Dandapat India E. DiBenedetto USA R. Finn USA R. L. Fosdick USA J. Frehse Germany A. Friedman USA R. Grimshaw UK J. Malek Czech Republic J. T. Oden USA R

Shen, Xuemin "Sherman"

199

A 40KW ROOF MOUNTED PV THERMAL CONCENTRATOR SYSTEM J.F.H. Smeltink1  

E-Print Network (OSTI)

during 2003-4. The system comprises eight 24 metre long single axis tracking reflective solar collectors and hydronic in-slab floor heating. Equipment associated with the solar collection system was installed during

200

Active Solar Heating | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Active Solar Heating Active Solar Heating Active Solar Heating June 24, 2012 - 5:58pm Addthis This North Carolina home gets most of its space heating from the passive solar design, but the solar thermal system supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography, NREL This North Carolina home gets most of its space heating from the passive solar design, but the solar thermal system supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography, NREL What does this mean for me? If you live in a cold climate and have unobstructed access to the sun during the heating season, an active solar heating system might make sense for you. You can buy a manufactured active solar system or build your own.

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Analysis of error floor of LDPC codes under LP decoding over the BSC  

SciTech Connect

We consider linear programming (LP) decoding of a fixed low-density parity-check (LDPC) code over the binary symmetric channel (BSC). The LP decoder fails when it outputs a pseudo-codeword which is not a codeword. We propose an efficient algorithm termed the instanton search algorithm (ISA) which, given a random input, generates a set of flips called the BSC-instanton and prove that: (a) the LP decoder fails for any set of flips with support vector including an instanton; (b) for any input, the algorithm outputs an instanton in the number of steps upper-bounded by twice the number of flips in the input. We obtain the number of unique instantons of different sizes by running the ISA sufficient number of times. We then use the instanton statistics to predict the performance of the LP decoding over the BSC in the error floor region. We also propose an efficient semi-analytical method to predict the performance of LP decoding over a large range of transition probabilities of the BSC.

Chertkov, Michael [Los Alamos National Laboratory; Chilappagari, Shashi [UNIV OF AZ; Vasic, Bane [UNIV OF AZ; Stepanov, Mikhail [UNIV OF AZ

2009-01-01T23:59:59.000Z

202

Effect of ozonation on fungal resistance of bamboo and oak flooring materials  

Science Journals Connector (OSTI)

Abstract Lignocellulosic materials are gaining increased interest as renewable sources of building materials. However, chemical and microbiological degradation can occur when lignocellulosic materials are exposed to environmental stressors such as ozone and elevated humidity. In this study, the effects of ozone treatment and solvent extraction on fungal growth rates of bamboo and oak flooring materials were investigated. One set of samples was extracted with a mixture of cyclohexane and ethanol solvents for 72 h to remove extractable compounds. Another set of materials was exposed continuously to ozone (2000 ?L m?3 or 2000 ppbv) for one to five weeks. Solvent-extracted and ozone-treated samples were incubated in closed chambers at 85% or 55% RH and 30 °C. Incubated samples were removed at regular time intervals for fungal growth evaluation. Ozone treatment caused chemical changes in bamboo and oak, which appeared to reduce bamboo's resistance to fungal attack. Longer ozone exposure led to higher susceptibility to fungal growth. Untreated and ozone-treated oak showed no evidence of fungal growth, suggesting that this material may contain fungi-inhibitory compounds that are not removed by these treatments. Also, a delay in fungal growth on cyclohexane/ethanol-extracted bamboo was observed, probably due to the extraction process removing substances that enhanced fungal growth.

Chi Hoang; Tinh Nguyen; Deborah Stanley; Andrew Persily; Richard L. Corsi

2014-01-01T23:59:59.000Z

203

SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION P  

NLE Websites -- All DOE Office Websites (Extended Search)

2NT00041628 2NT00041628 Final Report Covering research during the period 1 June, 2002 through 30 September, 2008 Support of Gulf of Mexico Hydrate Research Consortium: Activities to Support Establishment of a Sea Floor Monitoring Station Project Submitted by: University of Mississippi Center for Marine Resources and Environmental Technology 310 Lester Hall, University, MS 38677 Principal Authors: J. Robert Woolsey, Thomas M. McGee, Carol B. Lutken Prepared for: United States Department of Energy National Energy Technology Laboratory January, 2009 Office of Fossil Energy ii SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT DOE Award Number DE-FC26-02NT41628 FINAL TECHNICAL REPORT

204

SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION P  

NLE Websites -- All DOE Office Websites (Extended Search)

Oil & Natural Gas Technology Oil & Natural Gas Technology DOE Award No.: DE-FC26-06NT42877 Semiannual Progress Report HYDRATE RESEARCH ACTIVITIES THAT BOTH SUPPORT AND DERIVE FROM THE MONITORING STATION/SEA-FLOOR OBSERVATORY, MISSISSIPPI CANYON 118, NORTHERN GULF OF MEXICO Submitted by: CENTER FOR MARINE RESOURCES AND ENVIRONMENTAL TECHNOLOGY 111 BREVARD HALL, UNIVERSITY, MS 38677 Principal Author: Carol Lutken, PI Prepared for: United States Department of Energy National Energy Technology Laboratory August, 2011 Office of Fossil Energy ii HYDRATE RESEARCH ACTIVITIES THAT BOTH SUPPORT AND DERIVE FROM THE MONITORING STATION/SEA-FLOOR OBSERVATORY, MISSISSIPPI CANYON 118, NORTHERN GULF OF MEXICO SEMIANNUAL PROGRESS REPORT 1 JANUARY, 2011 THROUGH 30 JUNE, 2011

205

Support of Gulf of Mexico Hydrate Research Consortium: Activities to Support Establishment of a Sea Floor Monitoring Station Project  

SciTech Connect

The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health, was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical, geological, and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 (MC118) in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. These delays caused scheduling and deployments difficulties but many sensors and instruments were completed during this period. Software has been written that will accommodate the data that the station retrieves, when it begins to be delivered. In addition, new seismic data processing software has been written to treat the peculiar data to be received by the vertical line array (VLA) and additional software has been developed that will address the horizontal line array (HLA) data. These packages have been tested on data from the test deployments of the VLA and on data from other, similar, areas of the Gulf (in the case of the HLA software). The CMRET has conducted one very significant research cruise during this reporting period: a March cruise to perform sea trials of the Station Service Device (SSD), the custom Remotely Operated Vehicle (ROV) built to perform several of the unique functions required for the observatory to become fully operational. March's efforts included test deployments of the SSD and Florida Southern University's mass spectrometer designed to measure hydrocarbon gases in the water column and The University of Georgia's microbial collector. The University of Georgia's rotational sea-floor camera was retrieved as was Specialty Devices storm monitor array. The former was deployed in September and the latter in June, 2006. Both were retrieved by acoustic release from a dispensable weight. Cruise participants also went prepared to recover any and all instruments left on the sea-floor during the September Johnson SeaLink submersible cruise. One of the pore-fluid samplers, a small ''peeper'' was retrieved successfully and in fine condition. Other instrumentation was left on the sea-floor until modifications of the SSD are complete and a return cruise is accomplished.

J. Robert Woolsey; Thomas M. McGee; Carol Blanton Lutken; Elizabeth Stidham

2007-03-31T23:59:59.000Z

206

Hindawi Publishing Corporation 410 Park Avenue,15th Floor,#287 pmb,New York,NY 10022,USA  

E-Print Network (OSTI)

,15th Floor,#287 pmb,New York,NY 10022,USA http://www.hindawi.com/journals/denm/ Differential is not possible, you can contact denm.support@hindawi.com. Associate Editors N. Bellomo Italy J. L. Bona USA J. R. Cannon USA S.-N. Chow USA B. S. Dandapat India E. DiBenedetto USA R. Finn USA R. L. Fosdick USA J. Frehse

Plataniotis, Konstantinos N.

207

Passive Solar Home Design | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Passive Solar Home Design Passive Solar Home Design Passive Solar Home Design June 24, 2013 - 7:18pm Addthis This North Carolina home gets most of its space heating from the passive solar design, but the solar thermal system (top of roof) supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography. This North Carolina home gets most of its space heating from the passive solar design, but the solar thermal system (top of roof) supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography. What does this mean for me? A passive solar home means a comfortable home that gets at least part of its heating, cooling, and lighting energy from the sun. How does it work?

208

Heat Distribution Systems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Distribution Systems Distribution Systems Heat Distribution Systems May 16, 2013 - 5:26pm Addthis Radiators are used in steam and hot water heating. | Photo courtesy of ©iStockphoto/Jot Radiators are used in steam and hot water heating. | Photo courtesy of ©iStockphoto/Jot Heat is distributed through your home in a variety of ways. Forced-air systems use ducts that can also be used for central air conditioning and heat pump systems. Radiant heating systems also have unique heat distribution systems. That leaves two heat distribution systems -- steam radiators and hot water radiators. Steam Radiators Steam heating is one of the oldest heating technologies, but the process of boiling and condensing water is inherently less efficient than more modern systems, plus it typically suffers from significant lag times between the

209

Page not found | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

31 - 28840 of 31,917 results. 31 - 28840 of 31,917 results. Download DOE Organization Chart- July 23, 2013 The DOE Organization Chart is a diagram of the U.S. Department of Energy's structure along with the relationships and relative ranks of its parts and positions/jobs. http://energy.gov/downloads/doe-organization-chart-july-23-2013 Article Evaporative Cooling Basics Evaporative cooling uses evaporated water to naturally and energy-efficiently cool. http://energy.gov/eere/energybasics/articles/evaporative-cooling-basics Article Radiant Heating Basics Radiant heating systems involve supplying heat directly to the floor or to panels in the walls or ceiling of a house. The systems depend largely on radiant heat transfer: the delivery of heat directly from the hot surface to the people and objects in the room via the radiation of heat, which is

210

Autonomous Systems Lab Prof. Roland Siegwart  

E-Print Network (OSTI)

Autonomous Systems Lab Prof. Roland Siegwart Semester Thesis Supervised by: Author: Dr. C´edric Pradalier Bastian B¨ucheler Simon Lynen Robotic Floor Marking System using a Laser Measurement System Autumn;6.4 Convergence of Yaw Estimation . . . . . . . . . . . . . . . . . . . . . 27 6.4.1 Setup

Daraio, Chiara

211

9.15 Landslides in the Fluvial System  

Science Journals Connector (OSTI)

Landslides are among the main contributors of sediment to fluvial systems. The delivery of landslide debris to river channels and on valley floors creates flow obstacles, alters channel geometry, and modulates fluvial sediment flux. This chapter outlines key research trends in geomorphic hillslope–channel coupling; landslide sediment production and delivery; geomorphic imprints of landslides on channel and valley-floor geomorphology; and model approaches to predict such impacts at various scales.

O. Korup

2013-01-01T23:59:59.000Z

212

Ice cores drilled from lake and ocean floors, continents, and ice sheets provide geoscientists with the most extensive and accurate picture of the earth!s  

E-Print Network (OSTI)

zer Ice cores drilled from lake and ocean floors, continents, and ice sheets provide geoscientists produces 30 GB of raw imagery. With the ability to display core sections in high resolution, Corelyzer

Johnson, Andrew

213

SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT  

SciTech Connect

The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Every effort was made to locate and retain the services of a suitable vessel and submersibles or Remotely Operated Vehicles (ROVs) following the storms and the loss of the contracted vessel, the M/V Ocean Quest and its two submersibles, but these efforts have been fruitless due to the demand for these resources in the tremendous recovery effort being made in the Gulf area. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. The seafloor monitoring station/observatory is funded approximately equally by three federal Agencies: Minerals Management Services (MMS) of the Department of the Interior (DOI), National Energy Technology Laboratory (NETL) of the Department of Energy (DOE), and the National Institute for Undersea Science and Technology (NIUST), an agency of the National Oceanographic and Atmospheric Administration (NOAA).

J. Robert Woolsey; Tom McGee; Carol Lutken; Elizabeth Stidham

2006-06-01T23:59:59.000Z

214

Using ductwork to improve supply plenum temperature distribution in underfloor air distribution (UFAD) system  

E-Print Network (OSTI)

overhead air distribution design(1). 1.3 Thermal comfortS. Under Floor Air Distribution (UFAD) Design Guide. s.l. :load design tool for underfloor air distribution systems.

Pasut, Wilmer

2011-01-01T23:59:59.000Z

215

The upturned concrete beam system : an investigation of structural, environmental, and constructability performance  

E-Print Network (OSTI)

While the recently completed U.S. Federal Building in San Francisco features numerous sustainable aspects that reduce energy demand, the most impressive feature required a distinctive structural floor system. Designers ...

Young, Hunter A. (Hunter Andrew)

2009-01-01T23:59:59.000Z

216

Plancher solaire direct mixte \\`a double r\\'eseau en habitat bioclimatique - Conception et bilan thermique r\\'eel. Double direct solar floor heating in boclimatic habitation - Design and real energetical balance  

E-Print Network (OSTI)

This study presents a new direct solar floor heating technique with double heating network wich allows simultaneous use of solar and supply energy. Its main purpose is to store and to diffuse the whole available solar energy while regulating supply energy by physical means without using computer controlled technology. This solar system has been tested in real user conditions inside a bioclimatic house to study the interaction of non-inertial and passive walls on the solar productivity. Daily, monthly and annual energy balances were drawn up over three years and completed by real-time measurements of several physical on-site parameters. As a result the expected properties of this technique were improved. The use of per-hour solar productivity, saved primary energy and corrected solar covering ratio is recommended to analyze the performances of this plant and to allow more refined comparisons with other solar systems

De Larochelambert, Thierry

2009-01-01T23:59:59.000Z

217

DOE Zero Energy Ready Home Case Study, Ferguson Design and Construction, Inc., Sagaponak, NY, Custom Home  

Energy.gov (U.S. Department of Energy (DOE))

Case study of a DOE Zero Energy Ready Home in Long Island, NY, that scored HERS 43 without PV. This 5,088 ft2 custom home has R-25 double-stud walls, a vaulted roof with R-40 blown cellulose, R-10 XPS under slab, a hydro air system with 91% efficient boiler for forced air and radiant floor heat, and 100% LED lights.

218

SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT  

SciTech Connect

The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The primary objective of the group has been to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station has always included the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. This possibility has recently achieved reality via the National Institute for Undersea Science and Technology's (NIUST) solicitation for proposals for research to be conducted at the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has achieved a microbial dimension in addition to the geophysical and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments, planned for fall 2005, have had to be postponed and the use of the vessel M/V Ocean Quest and its two manned submersibles sacrificed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Every effort is being made to locate and retain the services of a replacement vessel and submersibles or Remotely Operated Vehicles (ROVs) but these efforts have been fruitless due to the demand for these resources in the tremendous recovery effort being made in the Gulf area. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. The seafloor monitoring station/observatory is funded approximately equally by three federal Agencies: Minerals Management Services (MMS) of the Department of the Interior (DOI), National Energy Technology Laboratory (NETL) of the Department of Energy (DOE), and the National Institute for Undersea Science and Technology (NIUST), an agency of the National Oceanographic and Atmospheric Administration (NOAA). Subcontractors with FY03 funding fulfilled their technical reporting requirements in the previous report (41628R10). Only unresolved matching funds issues remain and will be addressed in the report of the University of Mississippi's Office of Research and Sponsored Programs.

Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis; Bob A. Hardage; Jeffrey Chanton; Rudy Rogers

2006-05-18T23:59:59.000Z

219

Building America Technology Solutions for New and Existing Homes: Air-to-Water Heat Pumps with Radiant Delivery in Low Load Homes (Fact Sheet)  

Energy.gov (U.S. Department of Energy (DOE))

Researchers from Alliance for Residential Building Initiative worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation.

220

Sampling and analysis plan for sludge located on the floor and in the pits of the 105-K basins  

SciTech Connect

This Sampling and Analysis Plan (SAP) provides direction for the sampling of the sludge found on the floor and in the remote pits of the 105-K Basins to provide: (1) basic data for the sludges that have not been characterized to-date and (2) representative Sludge material for process tests to be made by the SNF Project/K Basins sludge treatment process subproject. The sampling equipment developed will remove representative samples of the radioactive sludge from underwater at the K Basins, depositing them in shielded containers for transport to the Hanford Site laboratories. Included in the present document is the basic background logic for selection of the samples to meet the requirements established in the Data Quality Objectives (DQO), HNF-2033, for this sampling activity. The present document also includes the laboratory analyses, methods, procedures, and reporting that will be required to meet the DQO.

BAKER, R.B.

1998-11-20T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

INTERACTION OF A SOLAR SPACE HEATING SYSTEM WITH THE THERMAL BEHAVIOR OF A BUILDING  

E-Print Network (OSTI)

solar con- trols test facility at Lawrence Berkeley Laboratory The interaction of baseboard, radiant panel, and furnace

Vilmer, Christian

2013-01-01T23:59:59.000Z

222

Support of Gulf of Mexico Hydrate Research Consortium: Activities of Support Establishment of a Sea Floor Monitoring Station Project  

SciTech Connect

The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research that shared the need for a way to conduct investigations of gas hydrates and their stability zone in the Gulf of Mexico in situ on a more-or-less continuous basis. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (SFO) on the sea floor in the northern Gulf of Mexico, in an area where gas hydrates are known to be present at, or just below, the sea floor and to discover the configuration and composition of the subsurface pathways or 'plumbing' through which fluids migrate into and out of the hydrate stability zone (HSZ) to the sediment-water interface. Monitoring changes in this zone and linking them to coincident and perhaps consequent events at the seafloor and within the water column is the eventual goal of the Consortium. This mission includes investigations of the physical, chemical and biological components of the gas hydrate stability zone - the sea-floor/sediment-water interface, the near-sea-floor water column, and the shallow subsurface sediments. The eventual goal is to monitor changes in the hydrate stability zone over time. Establishment of the Consortium succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among those involved in gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative methods and construct necessary instrumentation. Following extensive investigation into candidate sites, Mississippi Canyon 118 (MC118) was chosen by consensus of the Consortium at their fall, 2004, meeting as the site most likely to satisfy all criteria established by the group. Much of the preliminary work preceding the establishment of the site - sensor development and testing, geophysical surveys, and laboratory studies - has been reported in agency documents including the Final Technical Report to DOE covering Cooperative Agreement DEFC26-00NT40920 and Semiannual Progress Reports for this award, DE-FC26-02NT41628. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in MC118 in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. SFO completion, now anticipated for 2009-10, has, therefore, been delayed. Although delays caused scheduling and deployment difficulties, many sensors and instruments were completed during this period. Software has been written that will accommodate the data that the station retrieves, when it begins to be delivered. In addition, new seismic data processing software has been written to treat the peculiar data to be received by the vertical line array (VLA) and additional software has been developed that will address the horizontal line array (HLA) data. These packages have been tested on data from the test deployments of the VLA and on data from other, similar, areas of the Gulf (in the case of the HLA software). During the life of this Cooperative Agreement (CA), the CMRET conducted many cruises. Early in the program these were executed primarily to survey potential sites and test sensors and equipment being developed for the SFO. When MC118 was established as the observatory site, subsequent cruises focused on this location. Beginning in 2005 and continuing to the present, 13 research cruises to MC118 have been conducted by the Consortium. During September, 2006, the Consortium was able to secure 8 days aboard the R/V Seward Johnson with submersible Johnson SeaLink, a critical chapter in the life of the Observatory project as important documentation, tests, recoveries and deployments were accomplished during this trip (log appended). Consortium members have participated materially in a number of additional cruises including several of the NIUST autonomous underwater vehicle (AUV), Ea

J. Robert Woolsey; Thomas McGee; Carol Lutken

2008-05-31T23:59:59.000Z

223

Oxy-fuel combustion systems for pollution free coal fired power generation  

SciTech Connect

Jupiter Oxygen's patented oxy-fuel combustion systems1 are capable of economically generating power from coal with ultra-low emissions and increased boiler efficiency. Jupiter's system uses pure oxygen as the combustion agent, excluding air and thus nitrogen, concentrating CO2 and pollutants for efficient capture with near zero NOx production, reducing exhaust mass flow, and increasing radiant heat transfer. Flue-gas recirculation rates can be varied to add flexibility to new boiler designs using this technology. Computer modeling and thermal analysis have identified important design considerations in retrofit applications.

Ochs, Thomas L.; Oryshchyn, Danylo B.; Gross, Dietrich (Jupiter Oxygen Corp.); Patrick, Brian (Jupiter Oxygen Corp.); Gross, Alex (Jupiter Oxygen Corp.); Dogan, Cindy; Summers, Cathy A.; Simmons, William (CoalTeck LLC); Schoenfeld, Mark (Jupiter Oxygen Corp.)

2004-01-01T23:59:59.000Z

224

This form must be filled out in its entirety and returned to your academic advisor on the fourth floor of the IT building. Revised 2/2014  

E-Print Network (OSTI)

academic advisor on the fourth floor of the IT building. Revised 2/2014 FORM to enroll form with their academic advisor by April 1 for the fall semester and permission to enroll form must be completed and routed to your academic advisor

Zhou, Yaoqi

225

Prototype development of an apparatus to locate and map sea floor petroleum seepages. First quarterly technical progress report, August 1, 1995--October 31, 1995  

SciTech Connect

This document is the first quarterly technical progress report for the project entitled {open_quotes}Prototype Development of an Apparatus to Locate and Map Sea Floor Petroleum Seepages{close_quotes}. This report describes progress in three areas: electronic design, mechanical design, and experiment/research.

NONE

1995-12-01T23:59:59.000Z

226

TTUAB CARDBOARD RECYCLING PROTOCOL Fall 2011 Cardboard is stored on the first floor in the Department of Biological Sciences in the west  

E-Print Network (OSTI)

TTUAB CARDBOARD RECYCLING PROTOCOL ­ Fall 2011 Cardboard is stored on the first floor. On Friday, one individual who signed up for the cardboard recycling is responsible to transport the collected cardboard to recycle bin next to Murray Hall (dumpster is next to that building in the R2 parking

Rock, Chris

227

TTUAB CARDBOARD RECYCLING PROTOCOL 2013 Cardboard is stored on the first floor in the Department of Biological Sciences in the west  

E-Print Network (OSTI)

TTUAB CARDBOARD RECYCLING PROTOCOL 2013 Cardboard is stored on the first floor in the Department, the individual who signed up for the cardboard recycling is responsible for transporting the collected cardboard to recycle bin next to Murray Hall (dumpster is next to that building in the R2 parking lot and in close

Rock, Chris

228

TTUAB CARDBOARD RECYCLING PROTOCOL Fall 2012 Cardboard is stored on the first floor in the Department of Biological Sciences in the west  

E-Print Network (OSTI)

TTUAB CARDBOARD RECYCLING PROTOCOL ­ Fall 2012 Cardboard is stored on the first floor. On Friday, the individual who signed up for the cardboard recycling is responsible to transport the collected cardboard to recycle bin next to Murray Hall (dumpster is next to that building in the R2 parking

Rock, Chris

229

The influence of a diffusive sublayer on diagenesis at the sea floor  

E-Print Network (OSTI)

of the Atlantic Ocean by Armi and Millard (1976) and Armi (1977) shows that these conservative scalars are, indeed, well mixed to a height of at. least 10 meters above the bottom. Likewise, Schink, Guinasso, and Fanning (1975) failed to detect any system... of the Atlantic Ocean by Armi and Millard (1976) and Armi (1977) shows that these conservative scalars are, indeed, well mixed to a height of at. least 10 meters above the bottom. Likewise, Schink, Guinasso, and Fanning (1975) failed to detect any system...

Boudreau, Bernard P

2012-06-07T23:59:59.000Z

230

Cooling System Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cooling System Basics Cooling System Basics Cooling System Basics August 16, 2013 - 1:08pm Addthis Cooling technologies used in homes and buildings include ventilation, evaporative cooling, air conditioning, absorption cooling, and radiant cooling. Learn more about how these technologies work. Ventilation Ventilation allows air to move into and out of homes and buildings either by natural or mechanical means. Evaporative Cooling In dry climates, evaporative cooling or "swamp cooling" provides an experience like air conditioning, but with much lower energy use. An evaporative cooler uses the outside air's heat to evaporate water inside the cooler. The heat is drawn out of the air and the cooled air is blown into the space by the cooler's fan. Air Conditioning Air conditioners, which employ the same operating principles and basic

231

Cooling System Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cooling System Basics Cooling System Basics Cooling System Basics August 16, 2013 - 1:08pm Addthis Cooling technologies used in homes and buildings include ventilation, evaporative cooling, air conditioning, absorption cooling, and radiant cooling. Learn more about how these technologies work. Ventilation Ventilation allows air to move into and out of homes and buildings either by natural or mechanical means. Evaporative Cooling In dry climates, evaporative cooling or "swamp cooling" provides an experience like air conditioning, but with much lower energy use. An evaporative cooler uses the outside air's heat to evaporate water inside the cooler. The heat is drawn out of the air and the cooled air is blown into the space by the cooler's fan. Air Conditioning Air conditioners, which employ the same operating principles and basic

232

ENERGY ANALYSISF FOR WORKSHOPS WITH FLOOR-SUPPLY DISPLACEMENT VENTILATION UNDER THE U.S. CLIMATES  

E-Print Network (OSTI)

use more fan and boiler energy but less chiller energy than the mixing ventilation system. The total in order to handle the high cooling loads found in U.S. buildings. Thus, the displacement ventilation, the chiller efficiency is increased. Besides, the

Chen, Qingyan "Yan"

233

Comparison of the effects of floor and cage housing on the performance of five strains and crosses of egg production stocks  

E-Print Network (OSTI)

strains, found average hen housed product, on of 176 eggs for birds housed on the floor compared with 154 eggs foz compaxable b'rds in layaway batteries. The xesponse differences among stxains were incons'stent. Rowevex, Millex (19/6) reported moxe... of suz'vivors while the caged pullets showed signif icantly lower mox tality and heavier eggs, Consistent significant differences could not be demonstrated for the traits studied, namely the production index and sexual maturity. Francis {19...

Bailey, Bernice Boyce

2012-06-07T23:59:59.000Z

234

University of California, Davis, Health System Office of Medical Education  

E-Print Network (OSTI)

University of California, Davis, Health System Office of Medical Education Exhibitor Confirmation' tabletop or equivalent floor space. o Vendors provide their own electrical cords or pay for equipment provided by conference site AV services. o Decorating, security guard, internet and electricity

Leistikow, Bruce N.

235

Topic 5: Renewable Power 1Networking and Distributed Systems  

E-Print Network (OSTI)

Communications and Control in Smart Grid 10 · Wave power is the energy from ocean surface waves. · Orbital motion the device to the ocean floor to hold it. cable Power modules Tubular section #12;Wave Energy Converter DrTopic 5: Renewable Power 1Networking and Distributed Systems Department of Electrical & Computer

Mohsenian-Rad, Hamed

236

Modeling Interactions of the Rat's Place and Head Direction Systems  

E-Print Network (OSTI)

Modeling Interactions of the Rat's Place and Head Direction Systems A. David Redish and David S in a set of experiments by Sharp et al. (1990). 1 The Sharp et al., 1990 experiment Rats spent multiple sessions finding food scattered randomly on the floor of a black cylin­ drical arena with a white cue card

Touretzky, David S.

237

Fifth Floor Student Advisor  

E-Print Network (OSTI)

Bathroom Bathroom Bathroom 5106 5107 5108 5109 Student Advisor Bathroom Bathroom 5110 5111 5112 5113 5206 5208 5207 5209 Bathroom Bathroom 5210 Student Advisor 5211 5301 5303 5305 5307 5302 5304 5309 5411 5018 Restroom 5016 Lounge 5017 Kitchen 5015 Data Closet Elevator 54085406 54095407 Student Advisor

Gering, Jon C.

238

Third Floor Student Advisor  

E-Print Network (OSTI)

Bathroom Bathroom Bathroom 3106 3107 3108 3109 Student Advisor Bathroom Bathroom 3110 3111 3112 3113 3206 3208 3207 3209 Bathroom Bathroom 3210 Student Advisor 3211 3301 3303 3305 3307 3302 3304 3309 3411 3018 Restroom 3016 Lounge 3017 Kitchen 3015 Mechanical Elevator 34083406 34093407 Student Advisor

Gering, Jon C.

239

Fourth Floor Student Advisor  

E-Print Network (OSTI)

Bathroom Bathroom Bathroom 4106 4107 4108 4109 Student Advisor Bathroom Bathroom 4110 4111 4112 4113 4208 4207 4209 Bathroom Bathroom 4210 Student Advisor 4211 4301 4303 4305 4307 4302 4304 4309Bathroom Restroom 4016 Lounge 4017 Kitchen Elevator 44084406 44094407 Student Advisor Bathroom Bathroom 44044402

Gering, Jon C.

240

Sustainability Data and Analytics in Cloud-Based M2M Systems  

E-Print Network (OSTI)

and integrated: (1) data about building elements (e.g., floors, equipment, and electricity systems), (2) data. Dustdar e-mail: dustdar@dsg.tuwien.ac.at N. Bessis and C. Dobre (eds.), Big Data and Internet of ThingsSustainability Data and Analytics in Cloud-Based M2M Systems Hong-Linh Truong and Schahram Dustdar

Dustdar, Schahram

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

DOE Zero Energy Ready Home Case Study, Preferred Builders, Old...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

R-13 closed-cell spray foam under the slab and on basement walls, an ERV, and a gas boiler for forced air and radiant floor heat. Preferred Buildings, Inc. - Old Greenwich, CT...

242

DOE Zero Energy Ready Home Case Study: Clifton View Homes, Whidbey...  

Energy Savers (EERE)

The home has a ground-source heat pump provides radiant floor heat plus passive solar heating from large south-facing windows and bare concrete slabs for the first and second...

243

DOE Zero Energy Ready Home: Leganza Residence- Greenbank, Washington  

Energy.gov (U.S. Department of Energy (DOE))

This DOE Zero Energy Ready Home features structural insulated panel walls and roof, a 2-ton ground source heat pump, radiant floor heat, 7.1 kWh PV, and triple-pane windows.

244

DOE Zero Energy Ready Home Case Study 2013: Ithaca Neighborhood...  

Energy Savers (EERE)

boost * HVAC: 92.5 AFUE wall-hung condensing boiler for in-slab and below-floor radiant heat; no AC * Hot Water: 92.5 AFUE wall-hung condensing boiler with on-demand delivery *...

245

Design of passive/hybrid solar systems for gulf states manufactured metal building systems. Phase I. Final report  

SciTech Connect

The analysis, design, and market assessment of a proposed prototype solar-heated manufactured metal building has been developed. Energy collection is effected through the vertical wall solar collector system designed as a integral part of the structural system. Heat storage is effected by a floor slab. Other designs such as direct gain and Trombe wall with moveable insulation were evaluated. System economics and life cycle costs were examined and the costs of the design options were compared. (LEW)

Not Available

1980-09-15T23:59:59.000Z

246

Scaleable Clean Aluminum Melting Systems  

SciTech Connect

The project entitled 'Scaleable Clean Aluminum Melting Systems' was a Cooperative Research and Development Agreements (CRADAs) between Oak Ridge National Laboratory (ORNL) and Secat Inc. The three-year project was initially funded for the first year and was then canceled due to funding cuts at the DOE headquarters. The limited funds allowed the research team to visit industrial sites and investigate the status of using immersion heaters for aluminum melting applications. Primary concepts were proposed on the design of furnaces using immersion heaters for melting. The proposed project can continue if the funding agency resumes the funds to this research. The objective of this project was to develop and demonstrate integrated, retrofitable technologies for clean melting systems for aluminum in both the Metal Casting and integrated aluminum processing industries. The scope focused on immersion heating coupled with metal circulation systems that provide significant opportunity for energy savings as well as reduction of melt loss in the form of dross. The project aimed at the development and integration of technologies that would enable significant reduction in the energy consumption and environmental impacts of melting aluminum through substitution of immersion heating for the conventional radiant burner methods used in reverberatory furnaces. Specifically, the program would couple heater improvements with furnace modeling that would enable cost-effective retrofits to a range of existing furnace sizes, reducing the economic barrier to application.

Han, Q.; Das, S.K. (Secat, Inc.)

2008-02-15T23:59:59.000Z

247

Results of detailed analyses performed on boring cores extracted from the concrete floors of the Fukushima Daiichi nuclear power plant reactor buildings  

SciTech Connect

Due to the massive earthquake and tsunami on March 11, 2011, and the following severe accident at the Fukushima Daiichi Nuclear Power Plant, concrete surfaces within the reactor buildings were exposed to radioactive liquid and vapor phase contaminants. In order to clarify the situation of this contamination in the reactor buildings of Units 1, 2 and 3, selected samples were transported to the Fuels Monitoring Facility in the Oarai Engineering Center of JAEA where they were subjected to analyses to determine the surface radionuclide concentrations and to characterize the radionuclide distributions in the samples. In particular, penetration of radiocesium in the surface coatings layer and sub-surface concrete was evaluated. The analysis results indicate that the situation of contamination in the building of Unit 2 was different from others, and the protective surface coatings on the concrete floors provided significant protection against radionuclide penetration. The localized penetration of contamination in the concrete floors was found to be confined within a millimeter of the surface of the coating layer of some millimeters. (authors)

Maeda, Koji; Sasaki, S.; Kumai, M.; Sato, Isamu; Osaka, Masahiko; Fukushima, Mineo; Kawatsuma, Shinji [Japan Atomic Energy Agency, 4002 Narita, Oarai, Ibaraki 311-1393 (Japan); Goto, Tetsuo; Sakai, Hitoshi [Toshiba Corporation, 8, Shinsugita, Isogo-ku, Yokohama 235-8523 (Japan); Chigira, Takayuki; Murata, Hirotoshi [Tokyo Electric Power Company, 1-1-3 Uchisaiwai, Chiyoda-ku, Tokyo, 100-8560 (Japan)

2013-07-01T23:59:59.000Z

248

Building Energy Software Tools Directory: EnergyPeriscope  

NLE Websites -- All DOE Office Websites (Extended Search)

EnergyPeriscope EnergyPeriscope Logo for EnergyPeriscope EnergyPeriscope is a professional-level performance estimating and financial analysis engine. Use it to create financial performance reports for single- or multiple-technology energy solutions. EnergyPeriscope accommodates retrofit applications, new construction buildings, and "Energy Farms" for selling PV- or wind-generated electricity. Model PV, solar water heating, solar pool/spa heating, solar hydronic radiant floor systems, wind turbines and energy efficiency projects. Screen Shots Keywords Renewable energy performance analysis, financial analysis, sales proposals Validation/Testing Data results were validated against RETScreen, PVWatts and other energy analysis tools. Reports are available. Expertise Required

249

Portable, space-saving medical patient support system  

DOE Patents (OSTI)

A support platform having a stowed configuration and a deployed configuration on a floor. The support platform is related to stretcher devices that are used for transporting, confining, or conducting medical procedures on medical patients in medical emergencies. The support platform typically includes a work surface that has a geometric extent. A base that typically includes a plurality of frame members is provided, and the frame members are disposed across the geometric extent of, and proximal to, the work surface in the stowed configuration. The frame members are typically disposed on the floor in the deployed configuration. There is a foldable bracing system engaged with the work surface and engaged with the base. At least a portion of the foldable bracing system is disposed substantially inside at least a portion of the plurality of frame members in the stowed configuration. Further, the foldable bracing system is configured for translocation of the work surface distal from the base in the deployed configuration.

Bzorgi; Fariborz (Knoxville, TN)

2011-02-01T23:59:59.000Z

250

Design, Fabrication and Testing of an Infrared Ratio Pyrometer System for the Measurement of Gasifier Reaction Chamber Temperature  

SciTech Connect

Texaco was awarded contract DE-FC26-99FT40684 from the U.S. DOE to design, build, bench test and field test an infrared ratio pyrometer system for measuring gasifier temperature. The award occurred in two phases. Phase 1, which involved designing, building and bench testing, was completed in September 2000, and the Phase 1 report was issued in March 2001. Phase 2 was completed in 2005, and the results of the field test are contained in this final report. Two test campaigns were made. In the first one, the pyrometer was sighted into the gasifier. It performed well for a brief period of time and then experienced difficulties in keeping the sight tube open due to a slag accumulation which developed around the opening of the sight tube in the gasifier wall. In the second test campaign, the pyrometer was sighted into the top of the radiant syngas cooler through an unused soot blower lance. The pyrometer experienced no more problems with slag occlusions, and the readings were continuous and consistent. However, the pyrometer readings were 800 to 900 F lower than the gasifier thermocouple readings, which is consistent with computer simulations of the temperature distribution inside the radiant syngas cooler. In addition, the pyrometer readings were too sluggish to use for control purposes. Additional funds beyond what were available in this contract would be required to develop a solution that would allow the pyrometer to be used to measure the temperature inside the gasifier.

Tom Leininger

2005-03-31T23:59:59.000Z

251

A charging control strategy for active building-integrated thermal energy storage systems using frequency domain modeling  

Science Journals Connector (OSTI)

Abstract Primary space conditioning can be provided through active building-integrated thermal energy storage (BITES) systems, such as radiant space heating through concrete slabs. This approach can reduce peak space conditioning demand and energy costs while satisfying thermal comfort. However, thermal charging rates need to be predictively controlled due to the slow thermal response of BITES systems. This paper presents a charge control strategy using frequency domain models and room air temperature set-point profile as input. The models were previously verified with full-scale experiment data. The calculation procedures are demonstrated on active BITES systems with and without airflow to zone. Results show that the calculated charging rates satisfy the desired room air temperature set-point profiles. This control strategy is important for integrating the design and operation of active BITES systems because frequency domain models also provide important design information.

Yuxiang Chen; Andreas K. Athienitis; Khaled E. Galal

2014-01-01T23:59:59.000Z

252

Strategy Guideline: Compact Air Distribution Systems  

SciTech Connect

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

Burdick, A.

2013-06-01T23:59:59.000Z

253

Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 11, 0.11 Specialty systems  

SciTech Connect

General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for canopies; loading dock systems; tanks; domes (bulk storage, metal framing); louvers & vents; access floors; integrated ceilings; and mezzanine structures.

Not Available

1993-05-01T23:59:59.000Z

254

VIRTUAL MACHINES FOR MESSAGE BASED, REAL-TIME AND INTERACTIVE SIMULATION Department of Industrial and Systems Engineering  

E-Print Network (OSTI)

VIRTUAL MACHINES FOR MESSAGE BASED, REAL-TIME AND INTERACTIVE SIMULATION Hansoo Kim Chen Zhou machine interacts with the material handling system, personnel and cell or shop floor controller in real software tools that are not designed to explicitly model machine interactions. In this research, we develop

255

Pentek concrete scabbling system: Baseline report; Summary  

SciTech Connect

The Pentek concrete scabbling system consists of the MOOSE{reg_sign} scabbler, the SQUIRREL{reg_sign}-I and SQUIRREL{reg_sign}-III scabblers, and VAC-PAC. The scabblers are designed to scarify concrete floors and slabs using cross section, tungsten carbide tipped bits. The bits are designed to remove concrete in 3/8 inch increments. The bits are either 9-tooth or demolition type. The scabblers are used with a vacuum system designed to collect and filter the concrete dust and contamination that is removed from the surface. The safety and health evaluation during the human factors assessment focused on two main areas: noise and dust.

NONE

1997-07-31T23:59:59.000Z

256

Distribution of 2,4-Dichlorophenoxyacetic Acid in Floor Dust throughout Homes Following Homeowner and Commercial Lawn Applications:? Quantitative Effects of Children, Pets, and Shoes  

Science Journals Connector (OSTI)

First, in the main living areas of homes A and B there was ap proximately a 3-fold reduction in 2,4-D levels relative to the homeowner application study, contrasted with a 3-fold increase in 2,4-D levels in homes E and F. In the case of home B, there was a 2-fold increase in the 2,4-D level on the lawn, and in home F there was a 5-fold decrease in the level on the front lawn. ... Since the homeowners in homes B, E, and F removed or thoroughly rinsed shoes after self-application and before reentry, the differences between homeowner and commercial application tend to indicate that activity patterns of the family overshadow effects such as the applicator's reentry into the home or the level on the turf. ... These scenarios, in comparison with fully occupied homes, suggest that the postapplication 2,4-D floor dust levels of homes X and Y were caused primarily by intrusion mechanisms other than track-in and are presumed to involve resuspension of 2,4-D from turf followed by fine particle intrusion of the closed house (home Y) and an incremental addition of fine particle penetration as doors and windows were opened (home X). ...

Marcia G. Nishioka; Hazel M. Burkholder; Marielle C. Brinkman; Robert G. Lewis

1999-03-31T23:59:59.000Z

257

Evaluating Ventilation Systems for Existing Homes  

SciTech Connect

During the course of this project, an affordable and high performance ductwork system to directly address the problems of thermal losses, poor efficiency, and air leakage was designed. To save space and enable direct connections between different floors of the building, the ductwork system was designed in such a way that it occupied interior or exterior frame wall cavities. The ductwork system satisfied building regulations for structural support when bridging multiple floors, the spread of fire and smoke, and insulation to reduce the heat flow into or out of the building. Retrofits of urban residential buildings will be the main focus for the application of this ductwork system. Highly reflective foils and insulating materials were used to aid in the increase of the overall R-value of the ductwork itself and the wall assembly. It is expected that the proposed system will increase the efficiency of the HVAC system and the thermal resistance of the building envelope. The performance of the proposed ductwork design was numerically evaluated in a number of different ways. Our results indicate that the duct method is a very cost attractive alternative to the conventional method.

Aldrich, R.; Arena, L.

2013-02-01T23:59:59.000Z

258

An intelligent CNC machine control system architecture  

SciTech Connect

Intelligent, agile manufacturing relies on automated programming of digitally controlled processes. Currently, processes such as Computer Numerically Controlled (CNC) machining are difficult to automate because of highly restrictive controllers and poor software environments. It is also difficult to utilize sensors and process models for adaptive control, or to integrate machining processes with other tasks within a factory floor setting. As part of a Laboratory Directed Research and Development (LDRD) program, a CNC machine control system architecture based on object-oriented design and graphical programming has been developed to address some of these problems and to demonstrate automated agile machining applications using platform-independent software.

Miller, D.J.; Loucks, C.S.

1996-10-01T23:59:59.000Z

259

Floor San Francisco, CA 94104  

Energy Savers (EERE)

with other water users. Additionally, discharge from power plants kills billions of fish annually and overheats downstream waters. For these power plants, Section 316(b) of the...

260

Tsunamigenic Sea-Floor Deformations  

Science Journals Connector (OSTI)

...geodetic data. The qualitative characteristics (that is, variation of...real-time estimation of source characteristics of the TREMORS model [HN12...of Mw , Okal compares the characteristics of the source at high and...the Internet and dedicated intranets. In 1986, NOAA's Pacific...

Costas Synolakis; Philip Liu; H. Abelson Philip; George Carrier; Harry Yeh

1997-10-24T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Researchers at Montana State University and Idaho National Lab have developed a process to effectively and efficiently clean natural and man-made porous material of radioactive contamination. The system eliminates  

E-Print Network (OSTI)

to effectively and efficiently clean natural and man-made porous material of radioactive contamination. The system eliminates the practice of full demolition and removal of contaminated objects and can address contaminated substrate. Thus, building walls (interior or exterior), floors and ceilings can be remediated

Maxwell, Bruce D.

262

Roof and Attic Design Guidelines for new and retrofit Construction of Homes in Hot and Coild Climates  

SciTech Connect

Some guidelines for improving the energy efficiency of roofs and attics are presented and are based on the research of the DOE Building Technology. The results of combined analytical and experimental studies were used to benchmark computer tools, which in turn, were used to simulate homes in hot and cold climates. Adding floor and roof insulation, above deck ventilation, radiant barriers, cool color shingle, metal or tile roofs, sealing the attic floor, sealing the duct system and sealing the attic were simulated to compute the cost of energy savings. Results are prioritized to help building owners make an informed economic decision when contemplating roof and attic retrofits. Sealing the attic floor is a top retrofit option. The sealed attic approach and a new prototype roof assembly an insulated and ventilated roof are good options for retrofit work but have paybacks ranging from 15 to 25 years. A new sealed attic concept was simulated and computations show its simple payback is about 10 to 12 years in hot and cold climates; its first cost is significantly reduced from that of a spray foam approach. For new construction the best option is to keep the ducts out of the attic, make sure the attic floor is sealed and add at least code level of insulation to the ceiling.

Desjarlais, Andre Omer [ORNL] [ORNL; LaFrance, Marc [International Energy Agency] [International Energy Agency

2013-01-01T23:59:59.000Z

263

Syngas and hydrogen production in a volumetric radiant burner  

Science Journals Connector (OSTI)

The production of syngas is the most energy demanding and metal consuming stage in the conversion of gaseous hydrocarbons (GH's) into value-added products. Its complexity restrains many practical applications of chemical processing of GH's, especially for low scale of operation. The paper describes new compact and highly productive generator of syngas and hydrogen based on the combustion of GH's in volumetric permeable matrixes with locked IR radiation that can serve as a solution of this problem. It is shown that such simple devices can provide a highly efficient methane conversion into syngas and thus facilitate the utilization of low-capacity sources of GH's for economically feasible low scale syngas and hydrogen production from various local hydrocarbon sources.

V.S. Arutyunov; V.M. Shmelev; M. Yu Sinev; O.V. Shapovalova

2011-01-01T23:59:59.000Z

264

Simulation of radiant cooling performance with evaporative cooling sources  

E-Print Network (OSTI)

of 65%, and pump motor electric efficiency of 78%, totalof 65%, and pump motor electric efficiency of 78%. Forof 65%, and pump motor electric efficiency of 78%. For both

Moore, Timothy

2008-01-01T23:59:59.000Z

265

Non-destructive component separation using infrared radiant energy  

DOE Patents (OSTI)

A method for separating a first component and a second component from one another at an adhesive bond interface between the first component and second component. Typically the method involves irradiating the first component with infrared radiation from a source that radiates substantially only short wavelengths until the adhesive bond is destabilized, and then separating the first component and the second component from one another. In some embodiments an assembly of components to be debonded is placed inside an enclosure and the assembly is illuminated from an IR source that is external to the enclosure. In some embodiments an assembly of components to be debonded is simultaneously irradiated by a multi-planar array of IR sources. Often the IR radiation is unidirectional. In some embodiments the IR radiation is narrow-band short wavelength infrared radiation.

Simandl, Ronald F. (Knoxville, TN); Russell, Steven W. (Knoxville, TN); Holt, Jerrid S. (Knoxville, TN); Brown, John D. (Harriman, TN)

2011-03-01T23:59:59.000Z

266

Simulation of radiant cooling performance with evaporative cooling sources  

E-Print Network (OSTI)

continuous rigid EPS foam insulation. The roofing assemblybatt insulation between the studs, and continuous rigid foamfoam. This provides the baseline with the same thermal mass and insulation

Moore, Timothy

2008-01-01T23:59:59.000Z

267

Simulation of radiant cooling performance with evaporative cooling sources  

E-Print Network (OSTI)

a trade-off between cooling power and faster reaction time,a trade-off between cooling power and faster reaction time,derived potential peak cooling power of 77 W/m 2 (24 Btu/hr-

Moore, Timothy

2008-01-01T23:59:59.000Z

268

Influence of dust on the emissivity of radiant barriers  

E-Print Network (OSTI)

(Figure 5. 2. ) as F Fr-a r-r (22) where N is the number of dust particles considered in the problem and d is the total dust coverage of the barrier. This is valid when a large dust accumulation exists, and the statistical equivalent diameter... is the mean diameter. 31 Surface (Roof) Fr Fr ? i Dust Particles Fr d is calculated to all the dust particles Figure 5. 2. Shape factor from any surface to the dust particles. The shape factors from the surrounding planes (roof deck and gables...

Noboa, Homero Luis

2012-06-07T23:59:59.000Z

269

Simulation of radiant cooling performance with evaporative cooling sources  

E-Print Network (OSTI)

integrated control resets for supply air temperature and75.2°F) Cooling supply air temperature control Minimum AHUvary the VAV supply-air-temperature reset control mid-bands

Moore, Timothy

2008-01-01T23:59:59.000Z

270

Simulation of radiant cooling performance with evaporative cooling sources  

E-Print Network (OSTI)

HVAC airside network as a single constant-volume 60% efficient fan and path to the outside with total static pressure

Moore, Timothy

2008-01-01T23:59:59.000Z

271

Simulation of radiant cooling performance with evaporative cooling sources  

E-Print Network (OSTI)

Eindhoven, Netherlands, August 11-14, 2003 PAGE 66 SEindhoven, Netherlands, August 11-14, 2003. PAGE 67 S

Moore, Timothy

2008-01-01T23:59:59.000Z

272

Geothermal system saving money at fire station | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Geothermal system saving money at fire station Geothermal system saving money at fire station Geothermal system saving money at fire station April 9, 2010 - 3:45pm Addthis Joshua DeLung What will the project do? A geothermal heating and cooling system has enabled the substation to save taxpayers $15,000 annually when compared to a traditional system. The high temperature of the treatment building's water helps reduce the amount of energy needed to heat water in the substation. An environmentally friendly geothermal heating and cooling system in Pennsylvania will save taxpayers $15,000 a year as part of a new fire substation that will decrease emergency response times. The Alpha Fire Co. celebrated the opening of substation on the ground floor of the College Township municipal building earlier this year in State

273

Multi-Wavelength Visible Light Communication System Design Pankil Butala 1a  

E-Print Network (OSTI)

-converted light emitting diodes, or by filtering to iso- late the blue component from these sources. Multi efficient illumination devices called light emitting diodes (LED). The intensity of radiant flux emitted

Little, Thomas

274

Design of a Multicriteria Performance Model for JIT systems  

E-Print Network (OSTI)

elimination of waste with the participation of all levels of the organization, fr om the shop floor throughout the manager ial str ucture. Its intent is to develop the management process for designing and manufactur ing products so that the least resources... up the items needed fr om an upstream section. This is prefer able to the traditional system where an upstream section usually makes some lots of items and pushes them to the downstream section regardless of the work status at that section; thus...

Coulibaly, Soma

2012-06-07T23:59:59.000Z

275

Energy Blog | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6, 2013 6, 2013 The President's Plan to Reduce Carbon Pollution: Myths v. Reality Get the facts on President Obama's plan to address climate change. June 26, 2013 Installing a rooftop solar array as part of Los Angeles County's Feed-in Tariff program. | Photo courtesy of the Los Angeles Business Council. LA Rooftop Solar Project Goes Online in San Fernando Valley Los Angeles steps into the forefront of solar innovation with launch of feed-in tariff program. June 25, 2013 Urban Electric Power Takes Energy Storage from Startup to Grid-Scale Learn how a New York startup is trying to change the way we store energy. June 24, 2013 This North Carolina home gets most of its space heating from the passive solar design, but the solar thermal system (top of roof) supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography.

276

Energy Blog | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 26, 2013 June 26, 2013 The President's Plan to Reduce Carbon Pollution: Myths v. Reality Get the facts on President Obama's plan to address climate change. June 26, 2013 Installing a rooftop solar array as part of Los Angeles County's Feed-in Tariff program. | Photo courtesy of the Los Angeles Business Council. LA Rooftop Solar Project Goes Online in San Fernando Valley Los Angeles steps into the forefront of solar innovation with launch of feed-in tariff program. June 25, 2013 Urban Electric Power Takes Energy Storage from Startup to Grid-Scale Learn how a New York startup is trying to change the way we store energy. June 24, 2013 This North Carolina home gets most of its space heating from the passive solar design, but the solar thermal system (top of roof) supplies both domestic hot water and a secondary radiant floor heating system. | Photo courtesy of Jim Schmid Photography.

277

NREL: Energy Systems Integration Facility - Specialized Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

testing. Infrastructure within these laboratories includes in-floor carbon monoxide exhaust and diesel day tanks to support indoor generator operation, large roll-up doors...

278

Development of non-premixed porous inserted regenerative thermal oxidizer  

Science Journals Connector (OSTI)

In this study, a porous inserted regenerative thermal oxidizer (PRTO) system was developed for a... x emissions and high radiant efficiency. Zirconium dioxide (ZrO2...) ceramic ...

Jun-chun Zhang; Le-ming Cheng; Cheng-hang Zheng…

2013-09-01T23:59:59.000Z

279

ENERGY & ENVIRONMENT DIVISION. ANNUAL REPORT FY 1980  

E-Print Network (OSTI)

Symposium on Solar Thermal Power and Energy Systems, Junein that the radiant solar-to-thermal energy conversion isto transfer thermal energy from the solar collector to a

Authors, Various

2010-01-01T23:59:59.000Z

280

Active charge/passive discharge solar heating systems: thermal analysis  

SciTech Connect

The performance of active charge/passive discharge solar space-heating systems is analyzed. This type of system combines liquid-cooled solar collector panels with a massive integral storage component that passively heats the building interior by radiation and free convection. The TRNSYS simulation program is used to evaluate system performance and to provide input for the development of a simplified analysis method. This method, which provides monthly calculations of delivered solar energy, is based on Klein's Phi-bar procedure and data from hourly TRNSYS simulations. The method can be applied to systems using a floor slab, a structural wall, or a water tank as the storage component. Important design parameters include collector area and orientation, building heat loss, collector and heat-exchanger efficiencies, storage capacity, and storage to room coupling.

Swisher, J.

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Page 1 of 42 BUILDING ENERGY RESEARCH GRANT  

E-Print Network (OSTI)

at the UC Davis Engineering Shop, and John McNamara of Lightning Demolition were essential to onPage 1 of 42 BUILDING ENERGY RESEARCH GRANT (BERG) PROGRAM BERG FINAL REPORT Improving Cost Effectiveness of Radiant Floor Cooling University of California, Davis Western Cooling Efficiency Center 1450

California at Davis, University of

282

DOE Zero Energy Ready Home: Montlake Modern- Seattle, Washington  

Energy.gov (U.S. Department of Energy (DOE))

This DOE Zero Energy Ready Home features structural insulated panel walls and roof, an air-to-water heat pump plus radiant floor heat; 100% LED lighting; filtered-fan-powered fresh air intake; triple-pane windows, and 9.7 kWh PV for electric car charging station.

283

DOE Zero Energy Ready Home: Leganza Residence - Greenbank, Washington...  

Energy Savers (EERE)

panel (SIPs) walls, a 10.25-inch SIPS roof, an R-20 insulated slab, a 2-ton ground source heat pump, radiant floor heat, 7.1 kWh PV, and triple-pane windows. DOE Zero Energy Ready...

284

Going for Gold The Tercero Housing II project  

E-Print Network (OSTI)

in six areas: - Sustainable Sites - Water Savings - Energy Efficiency - Materials Selection - Indoor insulated windows which allow only 21% of radiant sun rays, while providing 65% of daylight. Energy-efficient, and plastic. Recycling collections at every floor. Use of recycled content materials throughout for steel

Schladow, S. Geoffrey

285

Prototype development of an apparatus to locate and map sea floor petroleum seepages. 1: Quarterly technical progress report, August 1--October 31, 1995  

SciTech Connect

There has been progress in three areas: electronic design, mechanical design, and experiment/research. Originally it had been conceived that off-the-shelf components could be developed into a system. This approach, which employed a single Keithley electrometer, was eventually set aside because inadequate impedance was noted in the switching circuitry. A design employing multiple electrometer amplifiers, each of high impedance (0.3 x 10E15 ohms) having no switching between the measurement electrodes and the amplifiers, was adopted. No significant changes in the mechanical design were made. Objectives in this work also include (a) the prediction and future interpretation of measured electrical potentials which are directly interpretable in terms of sulfide, hydrosulfide, and sulfate ion concentrations in marine sediments; (b) the development of an information base for presentation to potential clients; and (c) the location of marine regions of activity and the assessment of possible findings.

Thompson, K.F.

1995-10-31T23:59:59.000Z

286

Advanced Integrated Systems Technology Development  

E-Print Network (OSTI)

by the fact that the fan coil units were undersized for thethe 11 th floor but the fan coil units were still running attype – York, variable speed fan coil unit, Tate. ? Room air

2013-01-01T23:59:59.000Z

287

Blow out preventer handling system  

SciTech Connect

A system for testing and installing a blow out preventer on a floating vessel and offshore drilling rigs, although the system may be used on other rotary drilling rigs, is disclosed. Retractable rotary table supporting beams are disposed over the moon pool and the rotary table is releasably connected to them. Retractable sub-structure beams are provided below the rotary table so that means provided to move the assembled blow out preventer can move it through an opening in the derrick and over the moon pool when the rotary beams are retracted. Retractable moon pool skid beams are provided which support the blow out preventer when skidded through the moon pool opening in the substructure. In one aspect of the invention, the means connecting the rotary table to its support beams are self-aligning to that once the rotary table is aligned it can be removed and replaced without any further alignment. Also, support shoulders are provided on the main blow out preventer and lower riser section thereof which engage and are supported by the moon pool beams, so that the rotary support beams, rotary table and sub-structure support beams can be replaced and the blow out preventer hooked up to the riser, drill string or casing, the moon pool beams retracted and the blow out preventer lowered in the moon pool to the sea floor.

Guinn, D.C.; Haggard, A.K.; Thomas, J.P.

1980-10-28T23:59:59.000Z

288

Performance of thermal distribution systems in large commercial buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Performance of thermal distribution systems in large commercial buildings Performance of thermal distribution systems in large commercial buildings Title Performance of thermal distribution systems in large commercial buildings Publication Type Journal Article LBNL Report Number LBNL-44331 Year of Publication 2002 Authors Xu, Tengfang T., François Rémi Carrié, Darryl J. Dickerhoff, William J. Fisk, Jennifer A. McWilliams, Duo Wang, and Mark P. Modera Journal Energy and Buildings Volume 34 Start Page Chapter Pagination 215-226 Abstract This paper presents major findings of a field study on the performance of five thermal distribution systems in four large commercial buildings. The five systems studied are typical single-duct or dual-duct constant air volume (CAV) systems and variable air volume (VAV) systems, each of which serves an office building or a retail building with floor area over 2,000 m2. The air leakage from ducts are reported in terms of effective leakage area (ELA) at 25 Pa reference pressure, the ASHRAE-defined duct leakage class, and air leakage ratios. The specific ELAs ranged from 0.7 to 12.9 cm2 per m2 of duct surface area, and from 0.1 to 7.7 cm2 per square meter of floor area served. The leakage classes ranged from 34 to 757 for the five systems and systems sections tested. The air leakage ratios are estimated to be up to one-third of the fan- supplied airflow in the constant-air-volume systems. The specific ELAs and leakage classes indicate that air leakage in large commercial duct systems varies significantly from system to system, and from system section to system section even within the same thermal distribution system. The duct systems measured are much leakier than the ductwork specified as "unsealed ducts" by ASHRAE. Energy losses from supply ducts by conduction (including convection and radiation) are found to be significant, on the scale similar to the losses induced by air leakage in the duct systems. The energy losses induced by leakage and conduction suggest that there are significant energy-savings potentials from duct-sealing and insulation practice in large commercial buildings

289

A Study of the Advanced Systems at the CMU Intelligent Workplace with an Evaluation of Potential Applications to Texas A&M International University  

E-Print Network (OSTI)

A detailed study has been conducted of the performance of several innovative aspects of the Intelligent Workplace (IW) at Carnegie Mellon University, a low energy consumption building that uses radiant heating, cooling and a desiccant ventilation...

Claridge, D. E.; Gong, X.; Verdict, M.; Clingenpeel, K.

290

Rooftop Unit Suite: RTU Challenge, RTU Advanced Controls and RTU Smart Monitoring and Diagnostic System  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Suite of Projects Suite of Projects RTU Suite: RTU Challenge, RTU Advanced Controls and RTU Smart Monitoring and Diagnostic System Michael Brambley, Ph.D. Pacific Northwest National Laboratory Michael.Brambley@pnnl.gov (509) 375-6875 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Packaged air conditioners and heat pumps (RTUs) are used in about 58% of all cooled commercial buildings, serving about 69% of the cooled commercial building floor space (EIA 2003) - Navigant estimates that packaged air conditioners

291

Rooftop Unit Suite: RTU Challenge, RTU Advanced Controls and RTU Smart Monitoring and Diagnostic System  

NLE Websites -- All DOE Office Websites (Extended Search)

Suite of Projects Suite of Projects RTU Suite: RTU Challenge, RTU Advanced Controls and RTU Smart Monitoring and Diagnostic System Michael Brambley, Ph.D. Pacific Northwest National Laboratory Michael.Brambley@pnnl.gov (509) 375-6875 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Packaged air conditioners and heat pumps (RTUs) are used in about 58% of all cooled commercial buildings, serving about 69% of the cooled commercial building floor space (EIA 2003) - Navigant estimates that packaged air conditioners

292

Impact of Different Glazing Systems on Cooling Load of a Detached Residential Building at Bhubaneswar, India  

E-Print Network (OSTI)

assuming north?south and east?west facings of the building. For each orientation, different types of glazing (Table 4) and different glazing areas are considered. The first case(the base case) assumes a single clear glazing with a window-to-wall ratio.... Floor plan of the east-west oriented residential building taken for study (not to scale) Table 1. The zones basic characteristics Zone Area (m2) Volume (m3) Occupancy (people/m2) Venti- lation (l/s) HVAC system Bed room1 15.12 52...

Sahoo, P. K.; Sahoo, R.

2010-01-01T23:59:59.000Z

293

The evaluation and design of aeration systems for the storage of cottonseed in Muskogee type houses  

E-Print Network (OSTI)

Tank Analog Model Three-dimensional, Solid Analog of Conductive Cement 36 41 VI DISCUSSION OP RESULTS The Thorndale, Texas, Cen-Tex Co-operative Oil Mill Aeration System Overhead ducts Aeration by Means of Tunnels Lateral Ducts Comparison... of 12' Lateral on 20' Center, 2' Tunnel Opening 47 13 Static Pressure Map of 20' Lateral on 28' Center, 2' Tunnel Opening 48 14 Static Pressure Map of 12' Lateral on 20' Center, 12" Overhead 20' Above Floor, 2' Tunnel Opening 49 15 Static Pressure Map...

Rundt, Ronald James

2012-06-07T23:59:59.000Z

294

A non-contact energy transferring system for an electric vehicle-charging system based on recycled products  

Science Journals Connector (OSTI)

A non-contact automatic charging system for electric vehicle application is presented. The principle is the same as that of the transformer where the primary and the secondary circuits are separable but coupled with each other without using the hand coupler. In this paper we present a possibility of removing the core of the secondary coil on the body for reducing the weight of the car. In our experiments the primary core which is placed on the earth floor is made of Mn–Zn ferrite with square shape as 1 m × 1 m × 10 mm for a large cross-sectional area. The steel floor of the car assists to pass the magnetic flux. An efficiency rate over 90% with the test device of 2 kW is obtained without the conventional secondary core. The leakage inductance is well compensated by a resonance capacitor inserted in the secondary coil. In this experiment the distance between the primary and the secondary coil is 100 mm and the switching frequency is 100 kHz . In addition we developed a pavement method for the system. The method utilizes plates made from the waste of expanded polystyrene and rubber mats made from used tire. The plates are set up on the rubber mats and these mats are arranged over the non-contact charging system. The pavements can be replaced easily when the system is exchanged. Therefore this pavement method is not only practical for the non-contact charging system but is also useful for recycling of resources and reduction of waste matters.

Y. Matsuda; H. Sakamoto; H. Shibuya; S. Murata

2006-01-01T23:59:59.000Z

295

An electronic procedure system for WSRC fuel material facility  

SciTech Connect

The production of naval fuel, like many production processes within the Westinghouse complex, depends very heavily on strict procedure compliance. Thus operators need to have quick access to procedures and they need to have some assurance that they are using the most current revision. This is often both difficult and time consuming on a production floor. In order to resolve some of these problems two members of the Naval Fuel Product Team are currently developing an electronic procedure system. It is the intent of the system to have workstations on the production floor. These workstations will be networked to a centralized computer used exclusively as a file server for holding the current revision of each procedure. By simply clicking a mouse on the appropriate icon, a user will be able to access any procedure required in his portion of the process. In this user friendly environment the operator can either read the procedure on the workstation screen or print a copy of the procedure at a nearby printer. Since it is often the case that a graphic is used in one procedure is also used in other procedures, we plan to store individual graphics separately from a given procedure. In this way when a graphic changes, only one correction needs to be made in order for that graphic to be automatically updated in every procedure in which it is used. In the future we plan to expand the system so that the operator will be able to enter procedure data into the procedure. We have plans for this to be a platform for both the Distributive Control and Nuclear Accountability Systems. Farther down the road we envision operating in a real-time environment were the workstation would be able to read data directly from equipment in the process. 14 figs.

Derr, S.M.; Sloan, C.W.

1989-01-01T23:59:59.000Z

296

Enhancing Floor Warden Skills Session III  

E-Print Network (OSTI)

information to: 1. Responding Fire Unit 2. UCSF PD On-Scene 3. UCSF ECC 9-911 UCSF Phone 476-1414 Cell Phone 4: 1. UCSF ECC 9-911 from UCSF Phone 2. 476-1414 from Cell Phone or non UCSF Phone #12;Who to report

Derisi, Joseph

297

Johannesburg First Floor, 17 Baker Street,  

E-Print Network (OSTI)

Array Processor Building, housing the MeerKAT computing services and back-up power diesel rotary UPS of the infrastructure elements required to operate the radio telescopes in the reserve; including roads, power, reticulation of power and optical fibre, and links to the national optical fibre network. The Astronomy Reserve

Jarrett, Thomas H.

298

neil@awaaz.de 116 Ground Floor,  

E-Print Network (OSTI)

@cs.stanford.edu Associate Professor Stanford University Gates Computer Science #384 Palo Alto, CA 94305-9035 USA Tapan S, & Verma, 1995). As broader segments of the population come online, many of them via mobile phones

Parikh, Tapan S.

299

Interoperability testing for shop floor measurement  

Science Journals Connector (OSTI)

Manufactured parts are typically measured to ensure quality. Measurement involves equipment and software from many different vendors, and interoperability is a major problem faced by manufacturers. The I++ Dimensional Measuring Equipment (DME) specification ... Keywords: interoperability, measurement, software testing

Fred Proctor; Bill Rippey; John Horst; Joe Falco; Tom Kramer

2007-08-01T23:59:59.000Z

300

Shop floor information management and SOA  

Science Journals Connector (OSTI)

Service Science is a new term for a new paradigm which aims at the solution of an obvious problem: How to make the increasing fusion of business and IT successful in a dynamically changing and risk adverse environment? This question has to be raised ...

Konrad Pfadenhauer; Burkhard Kittl; Schahram Dustdar; David Levy

2006-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Johannesburg First Floor, 17 Baker Street,  

E-Print Network (OSTI)

Carnarvon and Williston) on Wednesday, 6 November 2013 at 10h00 (GPS coordinates 30º 58' 12.2052" S; 21º 59

Jarrett, Thomas H.

302

Johannesburg First Floor, 17 Baker Street,  

E-Print Network (OSTI)

on the Klerefontein farm (10km outside Carnarvon; turn-off on the R63 between Carnarvon and Williston) on Wednesday

Jarrett, Thomas H.

303

COMET TA Floor Plan 100225.vc6  

NLE Websites -- All DOE Office Websites (Extended Search)

Rack Argus Chamber Interaction Chamber Work Station 8 3 0 2 - V B L as phere CL 420mm f rom N i nner wall. Lens h older E f ac e27mm f rom W i nner w all. Parabola CL 534m m from...

304

Aviation Combustion Toxicology: An Overview  

Science Journals Connector (OSTI)

......in a radiant heat furnace. Rats...the produced combustion products in...in both the combustion tube and radiant heat systems proved...literature data for CO2, low...acrolein, and heat expo- sures...primary toxic combustion gases and are...structures. The hydrocarbon constituents......

Arvind K. Chaturvedi

2010-01-01T23:59:59.000Z

305

Ch.2 Solar Energy to Earth and the Seasons  

E-Print Network (OSTI)

Light year is a unit of distance!!! #12;Our Solar System #12;Earth's orbit Earth's orbit around energy is radiant energy (i.e., radiant light and heat) from the Sun. #12;How is solar energy created Southern lights Northern lights #12;Learning Objective Three: Solar Radiation #12; Solar radiation

Pan, Feifei

306

Solar heating and hot water system installed at St. Louis, Missouri. Final report  

SciTech Connect

Information is provided on the solar heating and hot water system installed at the William Tao and Associates, Inc., office building in St. Louis, Missouri. The information consists of description, photos, maintenance and construction problems, final drawing, system requirements and manufacturer's component data. The solar system was designed to provide 50% of the hot water requirements and 45% of the space heating needs for a 900 square foot office space and drafting room. The solar facility has 252 square foot of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.

Not Available

1980-04-01T23:59:59.000Z

307

Simulating the generic job shop as a multi-agent system  

Science Journals Connector (OSTI)

A model combining Discrete Event System (DES) and Multi-Agent System (MAS) is proposed to simulate a real-time job shop so that it can work as a test bed to systematically study the performance of control rules and algorithms in dynamic job shop scheduling. A definition of a generic job shop is given considering dynamic events, shop floor layout and the Material Handling System (MHS). It is first simulated as a DES and then implemented as an MAS so that data recording and analysis can be naturally distributed to the most related entities and events can be executed simultaneously at different locations. The state changes of agents and the communication among them are illustrated with state charts and sequential diagrams in Unified Modelling Language (UML). The proposed model is validated with a case study through statistical analysis and comparison with reported works.

R. Zhou; H.P. Lee; A.Y.C. Nee

2008-01-01T23:59:59.000Z

308

Baker Construction, Cincinnati, Ohio. Solar energy system performance evaluation, October 1980-May 1981  

SciTech Connect

The Baker Construction site is a single family residence in Ohio with a passive solar heating system, which consists of 302 square feet of 62 degree sloped greenhouse glazing, a 35,500-pound concrete mass wall, 10,400-pound concrete slab floor, 20 phase change storage rods, six 1-kW electric baseboard heaters, and a wood stove. A solar fraction of 55% is reported. Also the solar savings ratio and conventional fuel savings are given. The performance of the greenhouse collector subsystem, the heat storage subsystem, and the space heating subsystem are summarized as well as total system performance. Energy savings and weather data are also included. The design of the system, performance evaluation techniques, and sensor technology are also presented. (LEW)

Spears, J.W.

1981-01-01T23:59:59.000Z

309

Library System Library System  

E-Print Network (OSTI)

Library System #12;Library System 5150 Anthony Wayne Drive David Adamany Undergraduate Library that for the current fiscal year, we've been given an additional $600,000 for our library materials budget. We're very subscriptions. The Wayne State University Libraries are deeply committed to providing our faculty and students

Cinabro, David

310

Low emission U-fired boiler combustion system  

DOE Patents (OSTI)

At least one main combustion chamber contains at least one pulverized coal burner. Each pulverized coal burner is operatively arranged for minimizing NO.sub.X production and for maintaining a predetermined operating temperature to liquefy ash within the combustion chamber. The combustion chamber includes a slag drain for removing slag from the combustion chamber. A slag screen is positioned in a generally U-shaped furnace flow pattern. The slag screen is positioned between the combustion chamber and a radiant furnace. The radiant furnace includes a reburning zone for in-furnace No.sub.X reduction. The reburning zone extends between a reburning fuel injection source and at least one overfire air injection port for injecting air.

Ake, Terence (North Brookfield, MA); Beittel, Roderick (Worcester, MA); Lisauskas, Robert A. (Shrewsbury, MA); Reicker, Eric (Barre, MA)

2000-01-01T23:59:59.000Z

311

Metering Systems  

Energy.gov (U.S. Department of Energy (DOE))

A variety of metering systems are currently on the market for Federal facility implementation. The information below outlines common metering system capabilities and common metering system components.

312

Engineering development of coal-fired high performance power systems, Phases 2 and 3. Quarterly progress report, October 1--December 31, 1996. Final report  

SciTech Connect

The goals of this program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of: {gt} 47% efficiency (HHV); NO{sub x}, SO{sub x}, and particulates {gt} 10% NSPS; coal providing {ge} 65% of heat input; all sold wastes benign; and cost of electricity 90% of present plant. Work reported herein is from Task 1.3 HIPPS Commercial Plant Design, Task 2,2 HITAF Air Heater, and Task 2.4 Duct Heater Design. The impact on cycle efficiency from the integration of various technology advances is presented. The criteria associated with a commercial HIPPS plant design as well as possible environmental control options are presented. The design of the HITAF air heaters, both radiative and convective, is the most critical task in the program. In this report, a summary of the effort associated with the radiative air heater designs that have been considered is provided. The primary testing of the air heater design will be carried out in the UND/EERC pilot-scale furnace; progress to date on the design and construction of the furnace is a major part of this report. The results of laboratory and bench scale activities associated with defining slag properties are presented. Correct material selection is critical for the success of the concept; the materials, both ceramic and metallic, being considered for radiant air heater are presented. The activities associated with the duct heater are also presented.

NONE

1996-12-31T23:59:59.000Z

313

Coal-fired high performance power generating system. Quarterly progress report, October 1, 1994--December 31, 1994  

SciTech Connect

This report covers work carried out under Task 3, Preliminary R and D, under contract DE-AC22-92PC91155, {open_quotes}Engineering Development of a Coal-Fired High Performance Power Generation System{close_quotes} between DOE Pittsburgh Energy Technology Center and United Technologies Research Center. The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of (1) > 47% thermal efficiency; (2) NO{sub x}, SO{sub x} and particulates {<=}25% NSPS; (3) cost {>=}65% of heat input; (4) all solid wastes benign. In our design consideration, we have tried to render all waste streams benign and if possible convert them to a commercial product. It appears that vitrified slag has commercial values. If the flyash is reinjected through the furnace, along with the dry bottom ash, then the amount of the less valuable solid waste stream (ash) can be minimized. A limitation on this procedure arises if it results in the buildup of toxic metal concentrations in either the slag, the flyash or other APCD components. We have assembled analytical tools to describe the progress of specific toxic metals in our system. The outline of the analytical procedure is presented in the first section of this report. The strengths and corrosion resistance of five candidate refractories have been studied in this quarter. Some of the results are presented and compared for selected preparation conditions (mixing, drying time and drying temperatures). A 100 hour pilot-scale stagging combustor test of the prototype radiant panel is being planned. Several potential refractory brick materials are under review and five will be selected for the first 100 hour test. The design of the prototype panel is presented along with some of the test requirements.

NONE

1995-08-01T23:59:59.000Z

314

CX-004700: Categorical Exclusion Determination | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0: Categorical Exclusion Determination 0: Categorical Exclusion Determination CX-004700: Categorical Exclusion Determination Colorado State Energy Program American Recovery and Reinvestment Act - Geothermal Power Direct Use Grant - City of Ouray CX(s) Applied: B2.1, B5.1 Date: 12/14/2010 Location(s): Ouray, Colorado Office(s): Energy Efficiency and Renewable Energy, Golden Field Office The City of Ouray is proposing to use $20,000 in State Energy Program funding to install geothermal radiant flooring in the existing 3,200 foot City shop building. The City of Ouray Public Works Department will cut out the central portion of the existing floor of the shop in preparation for the new radiant slab installation. The Public Works Staff will install the insulation, tubing and concrete reinforcement to standard that will permit

315

Assessment of Energy Use and Comfort in Buildings Utilizing Mixed-Mode Controls with Radiant Cooling  

E-Print Network (OSTI)

EnergyPlus plug-in for SketchUp to develop a detailed 24-files generated using the SketchUp Open Studio Plugin o Aday to day operations. SketchUp: An easy to use 3D design

Borgeson, Samuel Dalton

2010-01-01T23:59:59.000Z

316

Multi-pulse operation of a super-radiant backward-wave oscillator  

SciTech Connect

Theory of a backward-wave electron oscillator operating in the non-stationary regime of super-radiation of short powerful rf pulses is developed. It is shown that there exist multi-frequency regimes of generation of either two-peak or three-peak output signal with different characteristic frequencies in every peak. The use of such regimes allows increasing the duration, the peak power, and the total energy of the output super-radiation rf pulse.

Bandurkin, I. V. [Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov St., Nizhny Novgorod, 603950 (Russian Federation); Savilov, A. V. [Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov St., Nizhny Novgorod, 603950 (Russian Federation); Lobachevsky State University of Nizhny Novgorod, Nizhny Novgorod (Russian Federation)

2014-08-15T23:59:59.000Z

317

Assessment of Energy Use and Comfort in Buildings Utilizing Mixed-Mode Controls with Radiant Cooling  

E-Print Network (OSTI)

building occupants. An exceedance-based goal leaves room for comfort achieved in part through energy neutral

Borgeson, Samuel Dalton

2010-01-01T23:59:59.000Z

318

Radiant Barrier Insulation Performance in Full Scale Attics with Soffit and Ridge Venting  

E-Print Network (OSTI)

in an attic. Figure 1 shows the methods used to install the foil for the tests reviewed. In a brief review all of the characteristics, results and differences of the tests cannot be discussed. Other than the ORNL Karns house tests, there have been no full... that had natural ventilation rates, (ORNL and TVA) used soffit and gable venting and did not measure the ventilation rate. The other experimenters used forced ventilation and approximated either gable/gable or soffit/ridge venting. Since the roof deck...

Ober, D. G.; Volckhausen, T. W.

1988-01-01T23:59:59.000Z

319

Computer System,  

NLE Websites -- All DOE Office Websites (Extended Search)

undergraduate summer institute http:institutes.lanl.govistisummer-school 2015 Computer System, Cluster, and Networking Summer Institute Purpose The Computer System,...

320

Numerical Study on the Thermal Environment of UFAD System with Solar Chimney for the Data Center  

Science Journals Connector (OSTI)

Abstract To improve the thermal environment in the data center, a solar chimney was integrated with Under-floor Air Distribution (UFAD) system in the Computational Fluid Dynamics (CFD) software Airpak. By using the validated model, three types of solar chimney, such as solar chimney transversely over the hot and cold aisles, solar chimney lengthways above the cold or hot aisles, were simulated. The comparison between the model calculation result shows that all types of solar chimneys used in this paper has great potential in providing a better temperature and airflow distribution. Especially in the case of the solar chimney above the cold aisle, the temperature in upper zone of cold aisle can be decreased by 13 °C, and the temperature field inside the rack is improved greatly without any additional power.

Kai Zhang; Xiaosong Zhang; Shuhong Li; Geng Wang

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

VXIbus based optical transducer evaluation system  

SciTech Connect

The Bonneville Power Administration (BPA) recently undertook an investigation into using new fiber optic based Potential Transducers and Current Transducers (PT and CT) in their power system. This paper describes the Data Acquisition System (DAS) and associated hardware developed to gather information on the Optical devices performance in the field. Bonneville currently uses PT and CT devices based on magnetic principles that have been in operation for over 40 years. Some disadvantages in the current magnetic devices include their large size, the internal usage of oils some of which are hazardous PCBs, a requirement for connection to instrumentation through substation analog connections, and occasional explosive breakdowns which can injure workers. The main advantage to this technology is a well proven operational history. A few manufacturers have recently developed PT and CT devices based on fiber optics which solve many of the problems associated with the magnetic devices. They are lightweight, use no oils, and are connected to instrumentation through non conductive fiber optics. However, they are new technology, and have seen limited practical application. The BPA Laboratory Services first tested the performance of the optical devices selected for this test in the controlled environment of the laboratory. They were energized from well characterized sources and the output parameters such as accuracy, drift, and noise floor were measured with standard rack type test instrumentation. Once fully tested and calibrated in the laboratory, the optical devices were then installed at Keeler substation in Hillsboro Oregon on a 500KV bus to be evaluated in real world conditions. The optical transducers were connected to standard BPA meters and relays for this test. Some of the meters were modified to accept the low voltage outputs of the optical devices.

Tillett, J. [Bonneville Power Administration, Vancouver, WA (United States)

1995-12-31T23:59:59.000Z

322

Simulation of energy performance of underfloor air distribution (UFAD) systems  

E-Print Network (OSTI)

rate, sf per year UFAD penetration rate Stock Base yea r=and ventilation. Penetration rates based on raised access= Floor area * EUI * penetration rate*UFAD EUI savings from

2009-01-01T23:59:59.000Z

323

Summary Report: Control Strategies for Mixed-Mode Buildings  

E-Print Network (OSTI)

air conditioning systems include fan coil units (FCUs) and water-source heat pumpSource Heat Pump; radiant slab heating and cooling; low flow A/C dehumidifies air;

Brager, Gail; Borgeson, Sam; Lee, Yoonsu

2007-01-01T23:59:59.000Z

324

Heliostat Field and Receiver Efficiency Measurement on the Iea — 500 kWe — CRS at Almeria  

Science Journals Connector (OSTI)

The Heliostat and Receiver Measurement S...ystem (HERMES) is designed to evaluate the radiant flux distribution in front of a receiver aperture plane. The results of the Fall Measurement Campaign in 1982 on the S...

W. Schiel

1985-01-01T23:59:59.000Z

325

Pentek concrete scabbling system: Baseline report; Greenbook (chapter)  

SciTech Connect

The Pentek scabbling technology was tested at Florida International University (FIU) and is being evaluated as a baseline technology. This report evaluates it for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The Pentek concrete scabbling system consisted of the MOOSE, SQUIRREL-I, and SQUIRREL-III scabblers. The scabblers are designed to scarify concrete floors and slabs using cross-section, tungsten carbide tipped bits. The bits are designed to remove concrete in 318 inch increments. The bits are either 9-tooth or demolition type. The scabblers are used with a vacuum system designed to collect and filter the concrete dust and contamination that is removed from the surface. The safety and health evaluation conducted during the testing demonstration focused on two main areas of exposure: dust and noise. Dust exposure was minimal, but noise exposure was significant. Further testing for each of these exposures is recommended. Because of the outdoor environment where the testing demonstration took place, results may be inaccurate. It is feasible that the dust and noise levels will be higher in an enclosed operating environment. Other areas of concern were arm-hand vibration, whole-body vibration, ergonomics, heat stress, tripping hazards, electrical hazards, machine guarding, and lockout/tagout.

NONE

1997-07-31T23:59:59.000Z

326

An assessment of the use of direct contact condensers with wet cooling systems for utility steam power plants  

SciTech Connect

Potential use of a direct contact condenser for steam recovery at the turbine exhaust of a utility power plant using a wet cooling system is investigated. To maintain condensate separate from the cooling water, a bank of plate heat exchangers is used. In a case study for a nominal 130-MW steam power plant, two heat rejection systems, one using a conventional surface condenser and another using a direct contact condenser together with a set of plate heat exchangers are compared on the basis of their performance, operation and maintenance, and system economics. Despite a higher initial cost for the direct contact system, the advantages it offers suggests that this system is viable both technically and economically. Key to the improvements the direct contact system offers is a higher equivalent availability for the power system. Reduction of dissolved oxygen and other metallic ions in the condensate, reduced use of chemical scavengers and polishers, and potential elimination of a plant floor are also major benefits of this system. Drawbacks include added plant components and higher initial cost. The potential for long-term cost reduction for the direct contact system is also identified.

Bharathan, D.; Hoo, E. [National Renewable Energy Lab., Golden, CO (United States)] [National Renewable Energy Lab., Golden, CO (United States); D`Errico, P. [Stone and Webster Engineering Corp., Boston, MA (United States)] [Stone and Webster Engineering Corp., Boston, MA (United States)

1992-02-01T23:59:59.000Z

327

Solar project description for living systems single family residence, Davis, California  

SciTech Connect

Two independent systems are described - a direct gain passive solar space heating system and an active domestic hot water preheating system. Large south-facing windows and a clerestory skylight permit direct winter sun to enter the house. Solar energy thermal storage is provided by both water filled tubes and the concrete slab floor. Movable shutters and insulating curtains provide capability to reduce night heat losses. Summer overheat protection is provided by roof overhangs and by natural ventilation. A natural gas furnace and wood stove provide auxiliary space heat. The domestic hot water system has an array of liquid flat plate collector with a gross area of 53 square feet. Freeze protection is by drain-down. An 82-gallon solar preheat tank supplies water to a conventional 20-gallon domestic hot water tank. The collector, storage, heating load, and auxiliary loads subsystems and modes of operation are described for both systems. The house is instrumented for thermal performance evaluation. Original cost estimates for provisioning and installation of the solar system are given. (LEW)

Not Available

1981-08-31T23:59:59.000Z

328

Decision-feedback multiple differential detection for space-time coded OFDM systems  

E-Print Network (OSTI)

by an irreducible error floor if the fading bandwidth is larger than zero. Decision-feedback differential detection (DF-DD) is found to be a very effective method to reduce such an error floor with a very low computational complexity. In this thesis, we first apply...

Liu, Yan

2001-01-01T23:59:59.000Z

329

Systems Synthesis  

NLE Websites -- All DOE Office Websites (Extended Search)

Synthesis. Integration, and Control System synthesis, integration, and control requires creativity and a broad vision of the big picture of the system to be able to select the best...

330

File Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

File Systems File Systems File Systems For a general description of the different file systems available on PDSF please see Eliza File Systems and Other File Systems. Below is a summary of how STAR uses the various systems: /common The STAR software is installed on /common. For 32sl44 it is under /common/star/star44 and for sl53 it is under /common/star/star53. In both cases the software consists primarily of a STAR-specific ROOT installation on which releases of the STAR libraries are built as shown on the Local STAR Libraries page. /eliza3, /eliza6, /eliza9, /eliza14, /eliza15, /eliza17 STAR has space on 6 elizas as shown in the table below. File System star space (TB) use eliza3 39 production eliza6 9 production eliza9 39 production eliza14 34 production, user space under /eliza14/star/pwg

331

Advanced Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Advanced Systems: Advanced Systems: high Performance fenestration systems Research areas: Research activities to improve the performance of windows and other fenestration products must address window systems issues as well as Glazing Materials research. LBNL activities in the area of Advanced Systems include research at both the product level and the building envelope and building systems levels. Highly insulating windows - using non structural center layers Lower cost solutions to more insulating three layer glazing systems, with the potential to turn windows in U.S. heating dominated residential applications into net-energy gainers. Highly Insulating Window Frames In collaboration with the Norwegian University of Science and Technology, we are researching the potentials for highly insulating window frames. Our initial work examines European frames with reported U-factors under 0.15 Btu/hr-ft2-F. Future research aims to analyze these designs, verify these performance levels and ensure that procedures used to calculate frame performance are accurate.

332

Microfluidic Systems Integrated Microfluidic Systems**  

E-Print Network (OSTI)

Microfluidic Systems Integrated Microfluidic Systems** Rustem F. Ismagilov* Keywords: analytical methods · enzymes · microfluidics · microreactors · protein structures Microfluidic systems use networks of channels thinner than a human hair to manipulate nanoliter volumes of re- agents. The goal of microfluidics

Ismagilov, Rustem F.

333

Active charge/passive discharge solar heating systems: thermal analysis and performance comparisons  

SciTech Connect

This study analyzes the performance of active charge/passive discharge solar space heating systems. This type of system combines liquid-cooled solar collector panels with a massive integral storage component that passively heats the building interior by radiation and free convection. The TRNSYS simulation program is used to evaluate system performance and to provide input for the development of a simplified analysis method. This method, which provides monthly calculations of delivered solar energy, is based on Klein's Phi-bar procedure and data from hourly TRNSYS simulations. The method can be applied to systems using a floor slab, a structural wall, or a water tank as the storage component. Important design parameters include collector area and orientation, building heat loss, collector and heat-exchanger efficiencies, storage capacity, and storage-to-room coupling. Performance simulation results are used for comparisons with active and passive solar designs. Economic comparisons are based on these data and additional system features, such as cooling augmentation and integration of heating components with structural members.

Swisher, J.

1981-06-01T23:59:59.000Z

334

Carbon Systems  

SciTech Connect

The electronic states of a 'quantum dot-graphene monolayer-SiO{sub 2} + n{sup +}-Si substrate' system in an external magnetic field are studied. An analytical expression for charge transfer in this system is obtained. The electronic states of a 'quantum dot-graphene bilayer-SiO{sub 2} + n{sup +}-Si substrate' system are considered. The systems under study are interesting from the viewpoint of controlling the optical properties of a quantum dot by means of an applied electric field.

Alisultanov, Z. Z., E-mail: zaur0102@gmail.com [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation)

2013-06-15T23:59:59.000Z

335

Muon systems  

SciTech Connect

The designs of both the GEM and SDC muon systems an the technological choices are reviewed. In particular, the chamber options for the detectors are discussed.

Bensinger, J.

1991-10-01T23:59:59.000Z

336

Radionuclide calorimeter system  

DOE Patents (OSTI)

A circuit for measuring temperature differentials in a calorimeter is disclosed. The temperature differential between the reference element and sample element containing a radioactive material is measured via a wheatstone bridge arrangement of thermistors. The bridge is driven with an alternating current on a pulsed basis to maintain the thermal floor of the calorimeter at a low reference value. A lock-in amplifier connected to the bridge phase locks a signal from the bridge to the input pulsed AC signal to provide a DC voltage. The DC voltage is sampled over time and provided to a digital computer. The digital computer, using curve fitting algorithms, will derive a function for the sample data. From the function, an equilibrium value for the temperature may be calculated.

Donohoue, Thomas P. (Denver, CO); Oertel, Christopher P. (Arvada, CO); Tyree, William H. (Boulder, CO); Valdez, Joe L. (Denver, CO)

1991-11-26T23:59:59.000Z

337

Radionuclide calorimeter system  

DOE Patents (OSTI)

A circuit for measuring temperature differentials in a calorimeter is disclosed. The temperature differential between the reference element and sample element containing a radioactive material is measured via a Wheatstone bridge arrangement of thermistors. The bridge is driven with an alternating current on a pulsed basis to maintain the thermal floor of the calorimeter at a low reference value. A lock-in amplifier connected to the bridge phase locks a signal from the bridge to the input pulsed AC signal to provide a DC voltage. The DC voltage is sampled over time and provided to a digital computer. The digital computer, using curve fitting algorithms, will derive a function for the sample data. From the function, an equilibrium value for the temperature may be calculated. 7 figures.

Donohoue, T.P.; Oertel, C.P.; Tyree, W.H.; Valdez, J.L.

1991-11-26T23:59:59.000Z

338

Power system  

DOE Patents (OSTI)

A power system includes a prime mover, a transmission, and a fluid coupler having a selectively engageable lockup clutch. The fluid coupler may be drivingly connected between the prime mover and the transmission. Additionally, the power system may include a motor/generator drivingly connected to at least one of the prime mover and the transmission. The power-system may also include power-system controls configured to execute a control method. The control method may include selecting one of a plurality of modes of operation of the power system. Additionally, the control method may include controlling the operating state of the lockup clutch dependent upon the mode of operation selected. The control method may also include controlling the operating state of the motor/generator dependent upon the mode of operation selected.

Hickam, Christopher Dale (Glasford, IL)

2008-03-18T23:59:59.000Z

339

Study of hydrogen mixing within the combustion engineering system 80+ containment  

SciTech Connect

A scoping study is performed to determine how hydrogen distributes throughout an evolutionary, advanced pressurized water reactor (PWR) spherical containment given a variety of hydrogen inflows and delivery locations. The study uses MAAP and a preliminary containment design for the Combustion Engineering (C-E) System 80+{trademark} standard design as the bases for the detailed thermal-hydraulic analyses. Results are compared to applicable design criteria from the Advanced Light Water Reactor (ALWR) Requirements Document. The C-E System 80+ containment design is based on the Cherokee-Perkins System 80{sup R} spherical containment design, revised to accommodate ALWR Requirements Document design criteria. A feature of this design is the 500,000-gal in-containment refueling water storage tank (IRWST) located in the lower region of the containment building. This tank is the source for the safety injection and containment spray pumps, and the discharge location for the primary system safety and bleed valves. The containment design directs water accumulation on lower floors to the IRWST to preclude its depletion.

Hawley, J.T.; Hammersley, R.J.; Plys, M.G. (Fauske Associates, Inc., Burr Ridge, IL (USA))

1989-11-01T23:59:59.000Z

340

telecommunications system management  

Science Journals Connector (OSTI)

Communications system management applied to telecommunications systems, facilities, equipment, and components. See communications system , comm...

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas. Final report  

SciTech Connect

This document is the Final Report of the Solar Energy System Installed at the First Solar Heated Office Building, One Solar Place, Dallas, Texas. The Solar System was designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 Solargenics, series 76, flat plate collectors with a total area of 1596 square feet. The solar loop circulates an ethylene glycol-water solution through the collectors into a hot water system heat exchanger. The hot water storage subsystem consists of a heat exchanger, two 2300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water fixtures. The building cold water system provides make-up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described. The system became operational July 11, 1979.

Not Available

1980-06-01T23:59:59.000Z

342

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Furnaces and Boilers Residential Furnaces and Boilers Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of residential furnaces and boilers since 1987. Residential furnaces and boilers include gas, electric, and oil-fired furnaces and boilers that are used to provide central heating to residential dwellings. Furnaces heat air and distribute the heated air through the house using ducts. Boilers heat water, providing either hot water or steam for heating. Steam is distributed via pipes to steam radiators, and hot water can either be distributed via baseboard radiators, radiant floor systems, or can heat air via a coil. The standards for residential furnaces and boilers implemented in 1992 will save approximately 3.9 quads of energy and result in approximately $46.2 billion in energy bill savings for products shipped from 1992-2021. The standard will avoid about 206 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 40.4 million automobiles.

343

Low-noise detector and amplifier design for 100 ns direct detection CO{sub 2} LIDAR receiver  

SciTech Connect

The development and test results of a prototype detector/amplifier design for a background limited, pulsed 100 ns, 10--100 kHz repetition rate LIDAR/DIAL receiver system are presented. Design objectives include near-matched filter detection of received pulse amplitude and round trip time-of-flight, and the elimination of excess correlated detector/amplifier noise for optimal pulse averaging. A novel pole-zero cancellation amplifier, coupled with a state-of-the-art SBRC (Santa Barbara Research Center) infrared detector was implemented to meet design objectives. The pole-zero cancellation amplifier utilizes a tunable, pseudo-matched filter technique to match the width of the laser pulse to the shaping time of the filter for optimal SNR performance. Low frequency correlated noise, (l/f and drift noise) is rejected through a second order high gain feedback loop. The amplifier also employs an active detector bias stage minimizing detector drift. Experimental results will be provided that demonstrate near-background limited, 100 ns pulse detection performance given a 8.5--11.5 {micro}m (300 K B.B.) radiant background, with the total noise floor spectrally white for optimal pulse averaging efficiency.

Cafferty, M.M.; Cooke, B.J.; Laubscher, B.E.; Olivas, N.L.; Fuller, K.

1997-06-01T23:59:59.000Z

344

LRRB Pavement Management Systems Pavement Management Systems  

E-Print Network (OSTI)

LRRB Pavement Management Systems Pavement Management Systems Presented by: Michael Marti SRF for implementing and monitoring research results (RIC) #12;LRRB Pavement Management Systems LRRB Structure LRRB Current Pavement Management System Used ICON (Goodpointe) Year of Pavement Management System

Minnesota, University of

345

Human Resources Office Dalia Bldg. 2nd Floor,  

E-Print Network (OSTI)

for rainfed and irrigated environments in the dry areas of West Asia-North Africa (WANA) and the Nile valley for the improvement of bread and durum wheat within Central and West Asia and North Africa (CWANA) as part

346

Incentive program for the Cherokee Nation Enterprise floor staff.  

E-Print Network (OSTI)

??Many promotions at Cherokee Casino Resort are mass marketed and are not designed for a specific guest. Often guest are unaware of the promotions that… (more)

Teel, Justin

2008-01-01T23:59:59.000Z

347

Working Towards 100% Electronic Transactions on the Shop Floor  

E-Print Network (OSTI)

Drastic changes are taking place in the manufacturing environment—both in continuous process manufacturing and discrete parts manufacturing. Data communications and computer technologies are forging new disciplines and relationships in manufacturing...

Terwilliger, M.

348

UWMC Floor Maps for Pa ents and Visitors  

E-Print Network (OSTI)

Clinic Vascular Laboratory Pavilion Entrance #12;Level 3 Sky Bridge RR Elevator Radiology Recep on & Wai Radiology Satellite CASCADE TOWER Pulmonary Diagnos c Center Employee Health Emergency Department Security To Health Sciences, Medical School, Dental Clinics MONTLAKE TOWER S1 Parking For wheelchair access to S1

Yetisgen-Yildiz, Meliha

349

Indentation and recovery characteristics of common resilient floor coverings  

E-Print Network (OSTI)

ocedure ' a ~ ~ ~ ~ a i ~ a ~ ~ a . SX . VXXX ~ Sfakeriel Oats Anelyeie, . . . ', ~ . ~ ~ a 40 Rubber, Tile ~ ' ~ '' a ' ~ ' ~ i o i' a e . ~ ~ i ~, 80 ' Vinpl Asbestos Tile ~ ~ ~ e o ~ ~ ~ ~ ~ ' Xineleun'Tile ~ . e i e e- a a ~ ~ ~ ~ ' e 00 Asphslt...'. "' ' 4, Residoal Xndestotios, 'Of Rabber 'tile'. ~ -i ". ". *Os ' , TI Residual xadentatiod o* viapx, Asbestos . Tile p ~ ~ I ~ ~ l, ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 0, , ', se?%dnax indentation of Tioyl Asbestos Tile ~ ~ ~ ' ~ ~ ', ' ~ ~ ~ ~ ~ g...

Stewart, Billy Ray

2012-06-07T23:59:59.000Z

350

Indentation and Recovery Tests of Common Resilient Floor Coverings.  

E-Print Network (OSTI)

the total indentation character- istics of rubber, vinyl-asbestos and cork tile. The total indentation was smaller under the heavy and medium loads for the thinner materials. Little effect was noted under the light load. Differences in residual... indentation of materials due to material thickness was significant for cork and vinyl-asbestos tile. Tests indicated that residual indentation was greater for the thicker samples. The thinner gage of rubber tile tended to retain more residual indentation...

Stewart, B. R.; Kunze, O. R.; Hobgood, Price

1960-01-01T23:59:59.000Z

351

1752 Columbia Rd. NW, Fourth Floor Washington, DC 20009  

E-Print Network (OSTI)

homebuyers could benefit from significant financial savings each year. Installing solar panels on new homes solar panels in bulk at lower prices. When one takes into account the California Energy Commission DIEGO RESIDENTS, BUILDERS BENEFIT FROM SOLAR REQUIREMENTS San Diego residents and builders could benefit

Kammen, Daniel M.

352

Discontinuities in the History of Sea-floor Spreading  

Science Journals Connector (OSTI)

... following. Let X be the distance, measured parallel to the spreading direction, of a parcel of crust from the axis of the mid-ocean ridge. Then a lapse is ... occasional vulcanism and the effects of sedimentation.

ERIC D. SCHNEIDER; PETER R. VOGT

1968-03-30T23:59:59.000Z

353

Human Resources Office Dalia Bldg. 2nd Floor,  

E-Print Network (OSTI)

in the Dry Areas (ICARDA) is an international autonomous, non-profit, research organization temporarily based and structures Up to date knowledge of advanced tools and techniques for measuring wind and water erosion

354

Quantitative evaluation of bioturbation on the deep sea floor  

E-Print Network (OSTI)

between 1 and 10 cd kyr r by invoking the assumption that mixing is proportional to biomass. Plutonium distributions in deep sea sedi- ments (Noshkin and Bowcn, 1973) indicate abyssal mixing rates ranging from 100-400 cmP kyr r . AC KN OWLE DGEMEN TS... vii LIST OF TABLES TABLE PAGE l. Microtektite Distributions. Estimation of Mixing Rates by Dimensional Analysis of Sediment Working Rates 30 Mixing Rates inferred from the plutonium data of Noshkin and Bowen (1973). 33 4. Mixing Parameters from...

Guinasso, Norman Louis

1975-01-01T23:59:59.000Z

355

Natural System  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Natural System Natural System Evaluation and Tool Development - FY11 Progress Report Prepared for U.S. Department of Energy Used Fuel Disposition Program Yifeng Wang (SNL) Michael Simpson (INL) Scott Painter (LANL) Hui-Hai Liu (LBNL) Annie B. Kersting (LLNL) July 15, 2011 FCRD-USED-2011-000223 UFD Natural System Evaluation - FY11 Year-End Report July 15, 2011 2 DISCLAIMER This information was prepared as an account of work sponsored by an agency of the U.S. Government. Neither the U.S. Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness, of any information, apparatus, product, or process disclosed, or represents that its use would not infringe

356

Lighting Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Purple LED lamp Purple LED lamp Lighting Systems Lighting research is aimed at improving the energy efficiency of lighting systems in buildings and homes across the nation. The goal is to reduce lighting energy consumption by 50% over twenty years by improving the efficiency of light sources, and controlling and delivering illumination so that it is available, where and when needed, and at the required intensity. Research falls into four main areas: Sources and Ballasts, Light Distribution Systems, Controls and Communications, and Human Factors. Contacts Francis Rubinstein FMRubinstein@lbl.gov (510) 486-4096 Links Lighting Research Group Batteries and Fuel Cells Buildings Energy Efficiency Applications Commercial Buildings Cool Roofs and Heat Islands Demand Response Energy Efficiency Program and Market Trends

357

Solar heating and cooling system installed at Leavenworth, Kansas. Final report  

SciTech Connect

The solar heating and cooling system installed at the headquarters of Citizens Mutual Savings Association in Leavenworth, Kansas, is described in detail. The project is part of the U.S. Department of Energy's solar demonstration program and became operational in March, 1979. The designer was TEC, Inc. Consulting Engineers, Kansas City, Missouri and contractor was Norris Brothers, Inc., Lawrence, Kansas. The solar system is expected to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2200 square feet. Five, 3-ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3000 gallon chilled water storage tank. Two, 3000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

Not Available

1980-06-01T23:59:59.000Z

358

Advanced Recyclable Media System{reg_sign}. Innovative technology summary report  

SciTech Connect

The objective of the Large-Scale Demonstration Project (LSDP) is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory East`s (ANL) Chicago Pile-5 (CP-5) Research Reactor. The purpose of the LSDP is to demonstrate that using innovative and improved deactivation and decommissioning (D and D) technologies from various sources can result in significant benefits, such as decreased cost and increased health and safety, as compared with baseline D and D technologies. This report describes a demonstration of the Advanced Recyclable Media System{reg_sign} technology which was employed by Surface Technology Systems, Inc. to remove coatings from a concrete floor. This demonstration is part of the CP-5 LSDP sponsored by the US Department of Energy (DOE) Office of Science and Technology Deactivation and Decommissioning Focus Area (DDFA). The Advanced Recyclable Media System{reg_sign} (ARMS) technology is an open blast technology which uses a soft recyclable media. The patented ARMS Engineered Blast Media consists of a fiber-reinforced polymer matrix which can be manufactured in various grades of abrasiveness. The fiber media can be remade and/or reused up to 20 times and can clean almost any surface (e.g., metal, wood, concrete, lead) and geometry including corners and the inside of air ducts.

NONE

1998-12-01T23:59:59.000Z

359

The Mass Tracking System for the Integral Fast Reactor fuel cycle  

SciTech Connect

As part of the Fuel Cycle Facility (FCF) of Argonne National Laboratory`s Integral Fast Reactor (IFR) demonstration, a computer-based Mass-Tracking (MTG) System has been developed. The MTG System collects, stores, retrieves and processes data on all operations which directly affect the flow of process material through FCF and supports such activities as process modeling, compliance with operating limits (e.g., criticality safety), material control and accountability and operational information services. Its architecture is client/server, with input and output connections to operator`s equipment-control stations on the floor of FCF as well as to terminal sessions. Its heterogeneous database includes a relational-database manager as well as both binary and ASCII data files. The design of the database, and the software that supports it, is based on a model of discrete accountable items distributed in space and time and constitutes a complete historical record of the material processed in FCF. Although still under development, much of the MTG System has been qualified and is in production use.

Adams, C.H.; Beitel, J.C.; Birgersson, G.; Bucher, R.G.; Carrico, C.B.; Daly, T.A. [Argonne National Lab., IL (United States); Keyes, R.W. [Argonne National Lab., Idaho Falls, ID (United States)

1994-07-01T23:59:59.000Z

360

The Mass Tracking System -- Computerized support for MC and A and operations at FCF  

SciTech Connect

As part of Argonne National Laboratory`s Fuel Conditioning Facility (FCF), a computer-based Mass-Tracking (MTG) System has been developed. The MTG System collects, stores, retrieves and processes data on all operations which directly affect the flow of process material through FCF and supports such activities as process modeling, compliance with operating limits (e.g., criticality safety), material control and accountability and operational information services. Its architecture is client/server, with input and output connections to operator`s equipment-control stations on the floor of FCF as well as to dumb terminals and terminal emulators. Its heterogeneous database includes a relational-database manager as well as both binary and ASCII data files. The design of the database, and the software that supports it, is based on a model of discrete accountable items distributed in space and time and constitutes a complete historical record of the material processed in FCF. Although still under development, much of the MTG system has been qualified and is in production use.

Adams, C.H.; Beitel, J.C.; Birgersson, G.; Bucher, R.G.; Derstine, K.L.; Toppel, B.J. [Argonne National Lab., IL (United States); Goin, R.W.; Keyes, R.W.; Vollmer, M.A. [Argonne National Lab.-West, Idaho Falls, ID (United States)

1996-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

The use of ducts to improve the control of supply air temperature rise in UFAD systems: CFD and lab study  

Science Journals Connector (OSTI)

Abstract Cool supply air flowing through the underfloor plenum is exposed to heat gain from both the concrete slab (conducted from the warm return air on the adjacent floor below the slab) and the raised floor panels (conducted from the warmer room above). The magnitude of this heat gain can be quite high, resulting in undesirable loss of control of the supply air temperature from the plenum into the occupied space. These warmer supply air temperatures can make it more difficult to maintain comfort in the occupied space (without increasing airflow rates), particularly in perimeter zones where cooling loads reach their highest levels. How to predict plenum thermal performance is one of the key design issues facing practicing engineers – evidence from completed projects indicates that excessive temperature rise in the plenum can be a problem. One of the recommended strategies for addressing temperature rise in UFAD systems is the use of ductwork (flexible or rigid) within the underfloor plenum to deliver cool air preferentially to perimeter zones or other critical areas of high cooling demand. Several experiments were carried out in a full-scale underfloor plenum test facility, in order to characterize all the phenomena that take place in an underfloor plenum equipped with a fabric or metal duct. Experimental data were collected for validation of a computational fluid dynamics (CFD) model of the plenum. This paper describes the first part of a more comprehensive work, whose aim is to use the validated CFD plenum model to conduct simulations of a broader range of plenum design and operational parameters. This work proves that using ductwork within the underfloor plenum reduce the temperature rise in the plenum.

Wilmer Pasut; Fred Bauman; Michele De Carli

2014-01-01T23:59:59.000Z

362

NETL: Gasification Systems - Model Based Optimal Sensor Network Design for  

NLE Websites -- All DOE Office Websites (Extended Search)

Model Based Optimal Sensor Network Design for Condition Monitoring Model Based Optimal Sensor Network Design for Condition Monitoring Project Number: FE0005712 General Electric (GE) Global Research is developing an advanced model-based optimal sensor network to monitor the condition of the gasification section in an integrated gasification combined cycle (IGCC) plant. The work builds on model-based controls aimed at enhancing efficiency and operational flexibility through increased automation. Within an overall strategy of employing model-based online monitoring and predictive controls, GE Global Research is extending existing models for the gasifier and radiant syngas cooler to include the effects of degradation and fouling on the sensed variables like temperature etc., and will implement an estimation algorithm to assess the extent of gasifier refractory degradation and radiant syngas cooler fouling. An optimization-based solution will be employed to optimally place the hardware sensors utilized in the estimation algorithm in order to achieve the monitoring requirements at the lowest cost. The performance of the sensor placement algorithm and resulting monitoring solution will be demonstrated through simulations using representative test cases. The overall approach is one of the first to be applicable to condition monitoring of critical components in IGCC plants.

363

Article original Comparaison des productions de chaleur  

E-Print Network (OSTI)

-litter or conventional slatted floor sys- tems. The insulation and ventilation requirements for livestock buildings in slatted floor build- ings must be adapted to the deep-litter system, in which there is early composting with the deep-litter system to that predicted by models, and to that of a conventional slatted floor system

Boyer, Edmond

364

Development of a waste dislodging and retrieval system for use in the Oak Ridge National Laboratory gunite tank  

SciTech Connect

As part of the Gunite And Associated Tanks (GAAT) Treatability Study the Oak Ridge National Laboratory (ORNL) has developed a tank waste retrieval system capable of removing wastes varying from liquids to thick sludges. This system is also capable of scarifying concrete walls and floors. The GAAT Treatability Study is being conducted by the Department of Energy Oak Ridge Environmental Restoration Program. Much of the technology developed for this project was cosponsored by the DOE Office of Science and Technology through the Tanks Focus Area (TFA) and the Robotics Technology Development Program. The waste dislodging and conveyance (WD&C) system was developed jointly by ORNL and participants from the TFA. The WD&C system is comprised of a four degree-of-freedom arm with back driveable motorized joints. a cutting and dislodging tool, a jet pump and hose management system for conveyance of wastes, confined sluicing end-effector, and a control system, and must be used in conjunction with a robotic arm or vehicle. Other papers have been submitted to this conference describing the development and operation of the arm and vehicle positioning systems. This paper will describe the development of the WD&C system and its application for dislodging and conveyance of ORNL sludges from the GAAT tanks. The confined sluicing end-effector relies on medium pressure water jets to dislodge waste that is then pumped by the jet pump through the conveyance system out of the tank. This paper will describe the results of cold testing of the integrated system. At the conference presentation there will also be results from the field deployment. ORNL has completed fabrication of the WD&C system for waste removal and is full-scale testing, including testing of the confined sluicing end-effector.

Randolph, J.D.; Lloyd, P.D.; Burks, B.L. [and others

1997-03-01T23:59:59.000Z

365

System Verification II Systems Engineering  

E-Print Network (OSTI)

in safety critical systems to prevent unsafe values, e.g. high doses of radiation. Remember: not just should be able to: Explain the role & practice of debugging in the software process. Describe in detail the purpose, scope of, and activities comprising each of the three main phases of software testing. Conduct

Bryson, Joanna J.

366

Gasification Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

GASIFICATION SYSTEMS GASIFICATION SYSTEMS U.S. DEPARTMENT OF ENERGY TECHNOLOGY PROGRAM PLAN PREFACE ii DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference therein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any

367

Gasification system  

DOE Patents (OSTI)

A method and system for injecting coal and process fluids into a fluidized bed gasification reactor. Three concentric tubes extend vertically upward into the fluidized bed. Coal particulates in a transport gas are injected through an inner tube, and an oxygen rich mixture of oxygen and steam are injected through an inner annulus about the inner tube. A gaseous medium relatively lean in oxygen content, such as steam, is injected through an annulus surrounding the inner annulus.

Haldipur, Gaurang B. (Hempfield, PA); Anderson, Richard G. (Penn Hills, PA); Cherish, Peter (Bethel Park, PA)

1985-01-01T23:59:59.000Z

368

Gasification system  

DOE Patents (OSTI)

A method and system for injecting coal and process fluids into a fluidized bed gasification reactor. Three concentric tubes extend vertically upward into the fluidized bed. Coal particulates in a transport gas are injected through an inner tube, and an oxygen rich mixture of oxygen and steam are injected through an inner annulus about the inner tube. A gaseous medium relatively lean in oxygen content, such as steam, is injected through an annulus surrounding the inner annulus.

Haldipur, Gaurang B. (Hempfield, PA); Anderson, Richard G. (Penn Hills, PA); Cherish, Peter (Bethel Park, PA)

1983-01-01T23:59:59.000Z

369

Integrated System  

NLE Websites -- All DOE Office Websites (Extended Search)

Integrated Window System Our research activities in the field of high performance windows have led us to conclude that even by using high performance insulating glass units, low conductivity frames, and warm edge spacers, there are still untapped sources for improving energy efficiency in the design and use of residential windows. While such high performance windows are a dramatic improvement over conventional units, they do not reduce conductive losses through wall framing around the window, offer guarantees against excessive wall/window infiltration nor do they adapt to the daily and seasonal potentials for night insulation and summer shading. To meet this need, we have been working on the design, development, and prototyping of Integrated Window Systems (IWS) since 1993. Integrated Window Systems are a form of panelized construction where the wall panel includes an operable or fixed window sash, recessed night insulation, integral solar shading, and is built in a factory setting in order to minimize thermal short circuits and infiltration at joints. IWSs can be built in modular lengths to facilitate their installation with conventional wood frame stick construction or other forms of panelized construction.

370

Advanced Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimal gap width for double and triple glazing systems Optimal gap width for double and triple glazing systems Glazing systems in the US are commonly designed with a 1/2 " (12.7 mm) gap. The optimal gap width depends on many factors, such as gas fill (air, argon, krypton), the use of Low-e coatings, the environmental conditions (temperature difference across the window), and the calculation standard used. NFRC standard conditions are -18 C (-0.4 F) outside, and 21 C (69.8 F) inside. The calculation standard used in the US is based on the ISO 15099 standard. European standard conditions are 0 C (32 F) outside, and 20 C (68 F) inside. The calculation standard is based on the EN 673 standard. A number of common glazing configurations both with and without Low-e coatings, and with a variety of gas fills were evaluated using both the North American NFRC standard and the European EN 673 standard. All results were calculated using WINDOW 6.3 from LBNL. All IGU's (Insulated Glazing Units) have a standard height of 1 meter.

371

NETL: Coal Gasification Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Coal Gasification Systems News Gasifipedia Gasifier Optimization Feed Systems Syngas Processing Systems Analyses Gasification Plant Databases International Activity Program Plan...

372

Systems and Industry Analyses  

NLE Websites -- All DOE Office Websites (Extended Search)

systems and industry analyses News Gasifipedia Gasifier Optimization Feed Systems Syngas Processing Systems Analyses Gasification Plant Databases International Activity Program...

373

Power Systems Engineering  

NLE Websites -- All DOE Office Websites (Extended Search)

and distribution systems; steam, water, fuel, and environmental monitoring systems; alternative energy systems; reliability, availability, and maintainability assessments;...

374

Gasification Systems Project Portfolio  

NLE Websites -- All DOE Office Websites (Extended Search)

2014 Gasification Systems Project Portfolio News Gasifipedia Gasifier Optimization Feed Systems Syngas Processing Systems Analyses Gasification Plant Databases International...

375

Door Placard for No Automatic Fire Alarm with Automatic Fire Sprinkler Protection System  

E-Print Network (OSTI)

apartment with wet towels or sheets, and seal air ducts or other openings where smoke may enter Open address, floor, apartment number and the number of people in your apartment Seal the doors to your

Pawlowski, Wojtek

376

Door Placard for Fire Alarm and No Sprinkler System Fire Code Compliance  

E-Print Network (OSTI)

apartment with wet towels or sheets, and seal air ducts or other openings where smoke may enter Open address, floor, apartment number and the number of people in your apartment Seal the doors to your

Pawlowski, Wojtek

377

Door Placard for No Automatic Fire Alarm and No Sprinkler System  

E-Print Network (OSTI)

apartment with wet towels or sheets, and seal air ducts or other openings where smoke may enter Open address, floor, apartment number and the number of people in your apartment Seal the doors to your

Pawlowski, Wojtek

378

Calibration of the Accuscan II In Vivo System for I-125 Thyroid Counting  

SciTech Connect

This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-125 thyroid counting. The source used for the calibration was a DOE manufactured Am-241/Eu-152 source contained in a 22 ml vial BEA Am-241/Eu-152 RMC II-1 with energies from 26 keV to 344 keV. The center of the detector housing was positioned 64 inches from the vault floor. This position places the approximate center line of the detector housing at the center line of the source in the phantom thyroid tube. The energy and efficiency calibration were performed using an RMC II phantom (Appendix J). Performance testing was conducted using source BEA Am-241/Eu-152 RMC II-1 and Validation testing was performed using an I-125 source in a 30 ml vial (I-125 BEA Thyroid 002) and an ANSI N44.3 phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-125 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

Ovard R. Perry; David L. Georgeson

2011-07-01T23:59:59.000Z

379

Calibration of the Accuscan II In Vivo System for I-131 Thyroid Counting  

SciTech Connect

This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-131 thyroid counting. The source used for the calibration was an Analytics mixed gamma source 82834-121 distributed in an epoxy matrix in a Wheaton Liquid Scintillation Vial with energies from 88.0 keV to 1836.1 keV. The center of the detectors was position 64-feet from the vault floor. This position places the approximate center line of the detectors at the center line of the source in the thyroid tube. The calibration was performed using an RMC II phantom (Appendix J). Validation testing was performed using a Ba-133 source and an ANSI N44.3 Phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibrations including verification counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-131 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

Orval R. Perry; David L. Georgeson

2011-07-01T23:59:59.000Z

380

Water gate array for current flow or tidal movement pneumatic harnessing system  

DOE Patents (OSTI)

The invention, which provides a system for harnessing power from current flow or tidal movement in a body of water, comprises first and second hydro-pneumatic chambers each having ingress and egress below the water surface near the river or ocean floor and water gates operative to open or seal the ports to the passage of water. In an exemplary embodiment, the gates are sychronized by shafts so that the ingress ports of each chamber are connected to the egress ports of each other chamber. Thus, one set of gates is closed, while the other is open, thereby allowing water to flow into one chamber and build air pressure therein and allowing water to flow out of the other chamber and create a partial vacuum therein. A pipe connects the chambers, and an air turbine harnesses the air movement within the pipe. When water levels are equilibrated, the open set of gates is closed by a counterweight, and the other set is allowed to open by natural force of the water differential. The water gates may be comprised of a plurality of louvers which are ganged for simultaneous opening and closing. The system is designed to operate with air turbines or other pneumatic devices. Its design minimizes construction cost and environmental impact, yet provides a clean renewable energy source.

Gorlov, Alexander M. (Brookline, MA)

1991-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Bearing system  

DOE Patents (OSTI)

A bearing system includes backup bearings for supporting a rotating shaft upon failure of primary bearings. In the preferred embodiment, the backup bearings are rolling element bearings having their rolling elements disposed out of contact with their associated respective inner races during normal functioning of the primary bearings. Displacement detection sensors are provided for detecting displacement of the shaft upon failure of the primary bearings. Upon detection of the failure of the primary bearings, the rolling elements and inner races of the backup bearings are brought into mutual contact by axial displacement of the shaft.

Kapich, Davorin D. (Carlsbad, CA)

1987-01-01T23:59:59.000Z

382

E-Print Network 3.0 - ac phase noise Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Laser Amplitude and Phase Summary: Floor In a phase-noise setup, system noise floor verification is ac- complished by driving both ports... -Dynamic-Range Laser Amplitude and...

383

New Whole-House Solutions Case Study: S&A Homes; Pittsburgh,...  

Energy Savers (EERE)

HVAC system with a compact duct design that kept all ducts in conditioned space. Open-web floor trusses between the basement and first floors provided a path for ducts within...

384

Advanced Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Glazing Systems Glazing Systems Using Non-Structural Center Glazing Layers Windows in the United States use aproximately 2 quads a year in heating energy, approximately one third of all building space heating energy used and the largest single end use attributed to windows. Even if all existing windows were replaced with todayÂ’s ENERGY STAR low-e products (U values < 0.35 Btu/hr-ft2-F), windows related heating would still be over 1 Quad. Because heating loads are strongly tied to conductive losses, technologies which lead to lower window U-factors are the key to reducing heating energy. A 0.1 Btu/hr-ft2-F window is targeted as a product, which will meet the requirements of zero-energy homes. Dynamic control of solar gains will further reduce heating needs by allowing winter solar heat gains to be effectively utilized while limiting cooling season gains. Significant cooling load savings can also be expected from lower U-factor windows in certain climates and from dynamic windows in all climates.

385

Ignition system  

SciTech Connect

This patent describes an ignition system of an internal combustion engine which consists of: a permanent magnet supported by a rotary member of the engine adapted to rotate in synchronism with a rotary shaft of the engine; a generating coil for generating an electromotive force to produce an electric current as the permanent magnet acts on the generating coil during the rotation of the rotary member; an ignition capacitor charged by the electric current generated by the generating coil; a thyristor caused to turn on by a counter electromotive force generated by the generating coil to thereby cause the ignition capacitor to begin to discharge; and an ignition coil generating a high voltage as the ignition capacitor begins to discharge, to cause a spark discharge to take place in an ignition plug of the internal combustion engine.

Kondo, T.; Ohno, S.

1986-09-16T23:59:59.000Z

386

Computer Systems Administrator  

E-Print Network (OSTI)

Computer Systems Administrator Fort Collins, CO POSITION A Computer Systems Administrator (Non activities. RESPONSIBILITIES The System Administrator will provide Unix/Linux, Windows computer system or computer science, and three years computer systems administration experience. DURATION The work is planned

387

Solar system  

SciTech Connect

An improved solar heat collecting system is described comprising: a collecting means having upper and lower end caps; means for supporting the collecting means in a position generally perpendicular to ambit solar radiation and to permit periodic adjustment thereof; the support means including a base, a first support bar pivotally secured to the base and extending parallel to the ground, and a first support member extending perpendicular from the first support bar to the lower end cap. The support means also includes a second support bar pivotally secured to the base and extending generally parallel to the first support bar, a support leg having a lower portion that extends perpendicularly from the second support bar, an intermediate leg portion slidingly mounted on the lower leg portion and an upper leg portion pivotally secured to the intermediate leg portion, and a second support member extending perpendicularly from the upper leg portion to the upper end cap; lens means disposed above the collecting means for concentrating solar radiation on the collecting means; a pair of reflector means mounted below and on opposite sides of the radiation shadow of the lens means for concentrating solar radiation on the collecting means; mounting means for mounting the lens means and the reflector means. The mounting means includes first and second bracket means rotatively mounted respectively to the first and second support members. A pair of radially extending U-shaped reflector mounts have opposite ends secured to respective bracket means, and a pair of radially extending lens supports secured to respective bracket means; and means for rotating the mounting means and associated lens mean and reflector means to track the source of solar radiation whereby an improved, highly efficient solar heat collecting system is provided.

Gregory, S.T.

1987-02-24T23:59:59.000Z

388

Modeling, design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 1, BIPV/T system and house energy concept  

SciTech Connect

This paper is the first of two papers that describe the modeling, design, and performance assessment based on monitored data of a building-integrated photovoltaic-thermal (BIPV/T) system thermally coupled with a ventilated concrete slab (VCS) in a prefabricated, two-storey detached, low energy solar house. This house, with a design goal of near net-zero annual energy consumption, was constructed in 2007 in Eastman, Quebec, Canada - a cold climate area. Several novel solar technologies are integrated into the house and with passive solar design to reach this goal. An air-based open-loop BIPV/T system produces electricity and collects heat simultaneously. Building-integrated thermal mass is utilized both in passive and active forms. Distributed thermal mass in the direct gain area and relatively large south facing triple-glazed windows (about 9% of floor area) are employed to collect and store passive solar gains. An active thermal energy storage system (TES) stores part of the collected thermal energy from the BIPV/T system, thus reducing the energy consumption of the house ground source heat pump heating system. This paper focuses on the BIPV/T system and the integrated energy concept of the house. Monitored data indicate that the BIPV/T system has a typical efficiency of about 20% for thermal energy collection, and the annual space heating energy consumption of the house is about 5% of the national average. A thermal model of the BIPV/T system suitable for preliminary design and control of the airflow is developed and verified with monitored data. (author)

Chen, Yuxiang; Athienitis, A.K.; Galal, Khaled [Dept. of Building, Civil and Environmental Engineering, Concordia University, 1455 De Maisonneuve West, EV6.139, Montreal, Quebec (Canada)

2010-11-15T23:59:59.000Z

389

Hybrid solar thermal-photovoltaic systems demonstration, Phase I and II. Final technical progress report, July 5, 1979-December 1982  

SciTech Connect

The purpose of the project is to investigate a system based on combined photovoltaic/thermal (PV/T) panels to supply the energy needs of a small single family residence. The system finally selected and constructed uses PV/T panels which utilize air as the heat transfer medium. Optimization of thermal performance was accomplished by attaching metal fins to the back surface of each cell which significantly increased the heat transfer coefficient from the solar cells to the air stream. The other major components of the selected system are an air-to-air heat pump, a rock bin thermal energy storage bin, a synchronous dc-to-ac converter, a microprocessor to control the system, a heat exchanger for the domestic hot water system and of course the building itself which is a one story, well insulated structure having a floor area of 1200 ft/sup 2/. A prototype collector was constructed and tested. Based on this experience, twenty collectors, containing 2860 four inch diameter solar cells, were constructed and installed on the building. Performance of the system was simulated using a TRNSYS-derived program, modified to accommodate PV/T panels and to include the particular components included in the selected system. Simulation of the performance showed that about 65 percent of the total annual energy needs of the building would be provided by the PV/T system. Of this total, about one half is produced at a time when it can be used in the building and one half must be sold back to the utility.

Loferski, J.J. (ed.)

1983-12-01T23:59:59.000Z

390

Onsite Wastewater Treatment Systems: Spray Distribution System  

E-Print Network (OSTI)

Spray distribution systems for wastewater are much like lawn sprinkler systems, in that they spray treated wastewater over the surface of a yard. This publication explains how spray distribution systems work, what their design requirements are...

Lesikar, Bruce J.

2008-10-23T23:59:59.000Z

391

Documentation associated with the WESF preparation for receiving 25 cesium capsules from the Applied Radiant Energy Corporation (ARECO)  

SciTech Connect

The purpose of this report is to compile all documentation associated with facility preparation of WESF to receive 25 cesium capsules from ARECO. The WESF validated it`s preparedness by completing a facility preparedness review using a performance indicator checklist.

Pawlak, M.W.

1996-10-21T23:59:59.000Z

392

Performance Testing of Radiant Barriers (RB) with R11, R19, and R30 Cellulose and Rock Wool Insulation  

E-Print Network (OSTI)

lnvestlgated prevlously by ORNL, FSEC, and TVA. In each case, It was found that RBs, especially the RBR. do cause hlgher roof temperatures but that the Increase Is not large. In the worst case, ORNL found increases in roof temperatures of 10°F wlth the RBR... Attics Contalnlng Radlant Barrlers." Oak Ridge Natl onal Laboratory. Sponsored by the Department of Energy and TVA. ORNL/CON-200, July 1986. 5. Levins, W. P. and Karnitz, M. A.. "Heating Energy Measurement of Unoccupled Single-Faml ly Houses Wlth...

Hall, J. A.

1988-01-01T23:59:59.000Z

393

Light weight and economical exhaust heat exchanger for waste heat recovery using mixed radiant and convective heat transfer  

Energy.gov (U.S. Department of Energy (DOE))

A hybrid heat exchanger is designed to keep highly stressed materials around the working fluid at a moderate temperature so that it can operate at higher working fluid pressure.

394

Synergistic Bactericidal Effect of Simultaneous Near-Infrared Radiant Heating and UV Radiation against Cronobacter sakazakii in Powdered Infant Formula  

Science Journals Connector (OSTI)

...UV radiation, as well as NIR thermal energy in the powder bed, a rotational mixer...sakazakii in food production environments and households. Lancet 363 :39-40. doi: 10.1016...and advances in far infrared heating in Japan. Trends Food Sci. Technol. 5 :357-362...

Jae-Won Ha; Dong-Hyun Kang

2014-01-10T23:59:59.000Z

395

Separation system  

DOE Patents (OSTI)

A separation system for dewatering radioactive waste materials includes a disposal container, drive structure for receiving the container, and means for releasably attaching the container to the drive structure. Separation structure disposed in the container adjacent the inner surface of the side wall structure retains solids while allowing passage of liquids. Inlet port structure in the container top wall is normally closed by first valve structure that is centrifugally actuated to open the inlet port and discharge port structure at the container periphery receives liquid that passes through the separation structure and is normally closed by second valve structure that is centrifugally actuated to open the discharge ports. The container also includes coupling structure for releasable engagement with the centrifugal drive structure. Centrifugal force produced when the container is driven in rotation by the drive structure opens the valve structures, and radioactive waste material introduced into the container through the open inlet port is dewatered, and the waste is compacted. The ports are automatically closed by the valves when the container drum is not subjected to centrifugal force such that containment effectiveness is enhanced and exposure of personnel to radioactive materials is minimized.

Rubin, Leslie S. (Newton, MA)

1986-01-01T23:59:59.000Z

396

Integrated Nanofluidic Systems for Systems Biotechnology  

E-Print Network (OSTI)

Integrated Nanofluidic Systems for Systems Biotechnology Wednesday October 28 2009 Burchard 118, 11 in prestigious journals including Science and Nature Biotechnology. Hong's research interests include Bio

Fisher, Frank

397

NREL: Energy Systems Integration Facility - Systems Integration  

NLE Websites -- All DOE Office Websites (Extended Search)

system components for grid-connected, standalone, and microgrid applications Test large power system components such as inverters, diesel and natural gas generators, battery...

398

A Review on Indoor Optical Wireless Systems Chaturi Singh, AMIE  

E-Print Network (OSTI)

Kanpur, U.P.-208016 Joseph John, FIETE, Y.N.Singh MIETE, MIEEE Department of Electrical Engineering, IIT assistants for indoor use are rapidly growing in offices, manufacturing floors, shopping areas and warehouses cable free communication at very high bit rates (a few Gbps as compared to tens of Mbps supported

Singh Yatindra Nath

399

Minimal fusion systems.  

E-Print Network (OSTI)

??We define minimal fusion systems in a way that every non-solvable fusion system has a section which is minimal. Minimal fusion systems can also be… (more)

Henke, Ellen

2010-01-01T23:59:59.000Z

400

Object Management Systems  

E-Print Network (OSTI)

Object-Oriented Database Management Systems for EngineeringR. Cassel. Distribution Management Systems: Functions and8-PWR 1988. Network Management Systems 52 Subodh Bapat.

Gollu, Aleks Ohannes

1995-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Environmental Management System  

NLE Websites -- All DOE Office Websites (Extended Search)

Management System Environmental Management System An Environmental Management System is a systematic method for assessing mission activities, determining the environmental impacts...

402

Environmental Management System Plan  

E-Print Network (OSTI)

R-3 • Environmental Management System Plan References 30.of Energy, Safety Management System Policy, DOE P 450.4 (E), Environmental Management Systems ? Requirements with

Fox, Robert

2009-01-01T23:59:59.000Z

403

Earth System Modeling  

Science Journals Connector (OSTI)

Earth system models are important research tools for improving understanding ... climate system (and maybe never will), Earth system models nowadays typically focus on specific aspects, for...

Patrick Jöckel

2012-01-01T23:59:59.000Z

404

Geographic Information System (GIS)  

Science Journals Connector (OSTI)

The geographic information system is a branch of health information system and public health information system ...developed for the capture, storage, manipulation, analysis, and visualization of geographic ...

2008-01-01T23:59:59.000Z

405

DOE Zero Energy Ready Home Case Study, Preferred Builders, Old Greenwich, CT, Custom  

Energy.gov (U.S. Department of Energy (DOE))

Case study of a DOE Zero Energy Ready Home in Old Greenwich CT, that scored HERS 42 without PV or HERS 20 with PV. This 2,700 ft2 custom home has advanced framed walls with R-24 blown cellulose plus R-7.5 EPS rigid foam, membrane-coated OSB, a close-cell spray foamed attic, R-13 closed-cell spray foam under the slab and on basement walls, an ERV, and a gas boiler for forced air and radiant floor heat.

406

Logical Systems Incorporated The Help Systems  

E-Print Network (OSTI)

Logical Systems Incorporated The Help Systems T A B L E O F C O N T E N T S Introduction ..................................... page 2 HELP/CMD ..................................... page 3 HELPRESx ................................... page 17 #12;LDOS Help System Page 1 The LDOS HELP Systems Introduction This documentation covers all

Mann, Tim

407

System design description cone penetrometer system  

SciTech Connect

The system design description documents in detail the design of the cone penetrometer system. The systems includes the cone penetrometer physical package, raman spectroscopy package and moisture sensor package. Information pertinent to the system design, development, fabrication and testing is provided.

Seda, R.Y., Westinghouse Hanford

1996-08-12T23:59:59.000Z

408

Industrial and Systems engineering  

E-Print Network (OSTI)

Industrial and Systems engineering COLLEGE of ENGINEERING DepartmentofIndustrialandSystemsEngineering EDGE Engineering Entrepreneur Certificate Program is a great addition to an industrial and systems to expert clinical recommendations. engineering.wayne.edu/isefaculty Industrial and systems engineering

Berdichevsky, Victor

409

Systems and Industry Analyses  

NLE Websites -- All DOE Office Websites (Extended Search)

Gasifipedia Gasifier Optimization Feed Systems Syngas Processing Systems Analyses Gasification Plant Databases International Activity Program Plan Project Portfolio Project...

410

Gasification Systems Publications  

NLE Websites -- All DOE Office Websites (Extended Search)

Gasifipedia Gasifier Optimization Feed Systems Syngas Processing Systems Analyses Gasification Plant Databases International Activity Program Plan Project Portfolio Project...

411

Gasification Systems Publications  

NLE Websites -- All DOE Office Websites (Extended Search)

Publications News Gasifipedia Gasifier Optimization Feed Systems Syngas Processing Systems Analyses Gasification Plant Databases International Activity Program Plan Project...

412

Hospital Information System  

Science Journals Connector (OSTI)

A hospital information system is an information system for processing data, information and knowledge in hospital ...

2008-01-01T23:59:59.000Z

413

Enhanced Detection of Surface-Associated Bacteria in Indoor Environments by Quantitative PCR  

Science Journals Connector (OSTI)

...contaminated flooring materials were removed and the...room were disinfected. Diagram of the experimental...location of flooring material sections. Contamination...spores, the room air-handling system was turned off...settle onto the flooring materials. The levels of contamination...

Mark P. Buttner; Patricia Cruz-Perez; Linda D. Stetzenbach

2001-06-01T23:59:59.000Z

414

PIA - Human Resources System/Payroll System | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

System PIA - Human Resources SystemPayroll System More Documents & Publications PIA - INL PeopleSoft - Human Resource System PIA - INL SECURITY INFORMATION MANAGEMENT SYSTEM...

415

Influence strategies for systems of systems  

E-Print Network (OSTI)

Distributed decision making has been identified as a source of managerial complexity for leaders of systems of systems (SoS). A new framework, AIR (Anticipation-Influence-Reaction), is proposed to capture the feedback ...

Shah, Nirav Bharat, 1979-

2013-01-01T23:59:59.000Z

416

Heating System Specification Specification of Heating System  

E-Print Network (OSTI)

Appendix A Heating System Specification /* Specification of Heating System (loosely based */ requestHeat : Room ­? bool; 306 #12; APPENDIX A. HEATING SYSTEM SPECIFICATION 307 /* user inputs */ livingPattern : Room ­? behaviour; setTemp : Room ­? num; heatSwitchOn, heatSwitchOff, userReset : simple

Day, Nancy

417

Energy Systems Integration  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Systems Integration Systems Integration Ben Kroposki, PhD, PE Director, Energy Systems Integration National Renewable Energy Laboratory 2 Reducing investment risk and optimizing systems in a rapidly changing energy world * Increasing penetration of variable RE in grid * Increasing ultra high energy efficiency buildings and controllable loads * New data, information, communications and controls * Electrification of transportation and alternative fuels * Integrating energy storage (stationary and mobile) and thermal storage * Interactions between electricity/thermal/fuels/data pathways * Increasing system flexibility and intelligence Current Energy Systems Future Energy Systems Why Energy Systems Integration? 3 Energy Systems Integration Continuum Scale Appliance (Plug)

418

Systems Analysis Workshop Purpose  

NLE Websites -- All DOE Office Websites (Extended Search)

National Renewable Energy Laboratory National Renewable Energy Laboratory DOE Hydrogen Program DOE Hydrogen Program Systems Analysis Workshop Systems Analysis Workshop Systems Integration Production Delivery Conversion Application Education Codes & Standards Safety Tech Validation Storage Systems Integration Production Delivery Conversion Application Education Codes & Standards Safety Tech Validation Storage Washington D.C. 28-29 Jul 04 Dale Gardner Systems Integration Operated for the U.S. Department of Energy by Midwest Research Institute * Battelle 2 Systems Analysis Workshop Topics * Meeting Goals * Systems Integration * Roles/Responsibilities of Analysis Participants * Systems Analysis * From this Workshop * Capability Presentations 3 Systems Analysis Workshop Meeting Goals 1) Understand the roles and activities of the DOE Technology Analyst,

419

Rural Intelligent Transportation Systems  

E-Print Network (OSTI)

System--activates lights on a STOP sign as a vehicle approaches the sign. · Curve Warning System System--records data on vehicle behavior that can be analyzed and used as a design input. Design the systems. Each system is made up of detection nodes that trigger the sign nodes. Results Foderberg

Minnesota, University of

420

Fan System Assessment Tool  

Energy.gov (U.S. Department of Energy (DOE))

The Fan System Assessment Tool (FSAT) is a free online software tool that helps industrial users quantify energy use and savings opportunities in industrial fan systems. Use FSAT to understand how well your fan systems are operating, determine the economic benefit of system modifications, and establish which options are most economically viable when multiple opportunities exist for system modification.

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Fundamentals of Dynamical Systems  

Science Journals Connector (OSTI)

For the purposes of control system design, analysis, test, and repair, the most important part of the very broad subject known as system theory is the theory of dynamical systems. It is difficult to give a pre...

William S. Levine

2005-01-01T23:59:59.000Z

422

Analyzing Scrip Systems  

E-Print Network (OSTI)

Scrip systems provide a nonmonetary trade economy for exchange of resources. We model a scrip system as a stochastic game and study system design issues on selection rules to match potential trade partners over time. We ...

Johnson, Kristine Dianne

423

Hopper System Diagram  

NLE Websites -- All DOE Office Websites (Extended Search)

System Diagram System Diagram Diagram of IO architecture on Hopper Diagram of external IO services on the Hopper system Last edited: 2011-04-14 15:11:1...

424

Development of Operation System  

Science Journals Connector (OSTI)

We are gradually developing a total hospital information system known as GUNMAS (Gunma University Network for Medical-Hospital- Information Archiving System). an operation system is also being developed as part o...

Seiji Kato M.D.; Yasuharu Kitani M.D.…

1992-01-01T23:59:59.000Z

425

Steam System Survey Guide  

Energy.gov (U.S. Department of Energy (DOE))

This guide provides technical information for steam system operational personnel and plant energy managers on some of the major opportunities available to improve the energy efficiency and productivity of industrial steam systems. The guide covers five main areas of investigation: (1) profiling a steam system, (2) identifying steam properties for the steam system, (3) improving boiler operations, (4) improving resource utilization in the steam system, and (5) investigating energy losses in the steam distribution system.

426

1  

NLE Websites -- All DOE Office Websites (Extended Search)

Improvement in Clouds and the Earth's Radiant Energy Improvement in Clouds and the Earth's Radiant Energy System/Surface and Atmosphere Radiation Budget Dust Aerosol Properties, Effects on Surface Validation of Clouds and Radiative Swath D. Rutan and F. Rose Analytical Services and Materials Inc. Hampton, Virginia T.P. Charlock NASA Langley Research Center Hampton, Virginia Introduction Within the Clouds and the Earth's Radiant Energy System (CERES) science team (Wielicki et al. 1996), the Surface and Atmospheric Radiation Budget (SARB) group is tasked with calculating vertical profiles of heating rates, globally, and continuously, beneath CERES footprint observations of Top of Atmosphere (TOA) fluxes. This is accomplished using a fast radiative transfer code originally developed by Qiang Fu and Kuo-Nan Liou (Fu and Liou 1993) and subsequently highly modified by the

427

CONTRACTOR PURCHASING SYSTEM REVIEWS  

Energy Savers (EERE)

PURCHASING SYSTEM REVIEWS RISK ASSESSMENT MATRIX RISK CATEGORY PERFORMANCE SCHEDULE COST HIGH (3) --Performance data casts significant doubt on the ability of the system or key...

428

Abstract: Regularized Boussinesq systems  

E-Print Network (OSTI)

A Boussinesq System for Two-way Propagation of Nonlinear Dispersive Waves. In this report, we study a system which describes approximately the ...

429

Control system design method  

DOE Patents (OSTI)

A control system design method and concomitant control system comprising representing a physical apparatus to be controlled as a Hamiltonian system, determining elements of the Hamiltonian system representation which are power generators, power dissipators, and power storage devices, analyzing stability and performance of the Hamiltonian system based on the results of the determining step and determining necessary and sufficient conditions for stability of the Hamiltonian system, creating a stable control system based on the results of the analyzing step, and employing the resulting control system to control the physical apparatus.

Wilson, David G. (Tijeras, NM); Robinett, III, Rush D. (Tijeras, NM)

2012-02-21T23:59:59.000Z

430

Flex Fuel Vehicle Systems  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

& Variable Advanced Management Injection Injection Sensors Control Units Fuel Supply & Plastic Parts Control Transmission Engineering Gasoline Systems GSENS, GSENS-NA System...

431

Umbra's system representation.  

SciTech Connect

This document describes the Umbra System representation. Umbra System representation, initially developed in the spring of 2003, is implemented in Incr/Tcl using concepts borrowed from Carnegie Mellon University's Architecture Description Language (ADL) called Acme. In the spring of 2004 through January 2005, System was converted to Umbra 4, extended slightly, and adopted as the underlying software system for a variety of Umbra applications that support Complex Systems Engineering (CSE) and Complex Adaptive Systems Engineering (CASE). System is now a standard part Of Umbra 4. While Umbra 4 also includes an XML parser for System, the XML parser and Schema are not described in this document.

McDonald, Michael James

2005-07-01T23:59:59.000Z

432

Precision Diagnostic System  

NLE Websites -- All DOE Office Websites (Extended Search)

Precision Diagnostic System For NIF to reach the goal of ignition, it needs to produce highly shaped pulses that are precisely controlled. NIF's precision diagnostic system (PDS)...

433

NERSC File Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Systems Systems NERSC File Systems Overview NERSC file systems can be divided into two categories: local and global. Local file systems are only accessible on a single platform, providing best performance; global file systems are accessible on multiple platforms, simplifying data sharing between platforms. File systems are configured for different purposes. On each machine you have access to at least three different file system Home: Permanent, relatively small storage for data like source code, shell scripts, etc. that you want to keep. This file system is not tuned for high performance from parallel jobs. Referenced by the environment variable $HOME. Scratch: Large, high-performance file system. Place your large data files in this file system for capacity and capability computing. Data is

434

Achieve Continuous Injection of Solid Fuels into Advanced Combustion System Pressures  

SciTech Connect

The overall objective of this project is the development of a mechanical rotary-disk feeder, known as the Stamet Posimetric High Pressure Solids Feeder System, to demonstrate feeding of dry granular coal continuously and controllably into pressurized environments of up to 70 kg/cm2 (1,000 psi). This is the Phase III of the ongoing program. Earlier Phases 1 and II successfully demonstrated feeding into pressures up to 35 kg/cm{sup 2} (500 psi). The final report for those phases was submitted in April 2005. Based on the previous work done in Phases I & II using Powder River Basin coal provided by the PSDF facility in Wilsonville, AL, a Phase III feeder system was designed and built to accomplish the target of feeding the coal into a pressure of 70 kg/cm2 (1,000 psi) and to be capable of feed rates of up to 550 kilograms (1,200lbs) per hour. The drive motor system from Phase II was retained for use on Phase III since projected performance calculations indicated it should be capable of driving the Phase III pump to the target levels. The pump & motor system was installed in a custom built test rig comprising an inlet vessel containing an active live-wall hopper mounted on weigh cells in a support frame, transition into the pump inlet, transition from pump outlet and a receiver vessel containing a receiver drum supported on weigh cells. All pressure containment on the rig was rated to105 kg/cm{sup 2} (1,500psi) to accommodate the final pressure requirement of a proposed Phase IV of the program. A screw conveyor and batch hopper were added to transfer coal at atmospheric pressure from the shop floor up into the test rig to enable continuous feeding up to the capacity of the receiving vessel. Control & monitoring systems were up-rated from the Phase II system to cover the additional features incorporated in the Phase III rig, and provide closer control and expanded monitoring of the entire system. A program of testing and modification was carried out in Stamet's facility in CA, culminating in the first successful feeding of coal into the Phase III target of 70 kg/cm{sup 2} (1,000 psi) gas pressure in March 2007. Subsequently, repeated runs at pressure were achieved, and comparison of the data with Phase II results when adjusted for scale differences showed further power reductions of 40% had been achieved from the final Phase II pressure runs. The general design layout of a commercial-scale unit was conducted, and preliminary cost estimates made.

Derek L. Aldred; Timothy Saunders

2007-03-31T23:59:59.000Z

435

The Behavior and Effects of the Noble Metals in the DWPF Melter System  

SciTech Connect

Governments worldwide have committed to stabilization of high-level nuclear waste (HLW) by vitrification to a durable glass form for permanent disposal. All of these nuclear wastes contain the fission-product noble metals: ruthenium, rhodium, and palladium. SRS wastes also contain natural silver from iodine scrubbers. Closely associated with the noble metals are the fission products selenium and tellurium which are chemical analogs of sulfur and which combine with noble metals to influence their behavior and properties. Experience has shown that these melt insoluble metals and their compounds tend to settle to the floor of Joule-heated ceramic melters. In fact, almost all of the major research and production facilities have experienced some operational problem which can be associated with the presence of dense accumulations of these relatively conductive metals and/or their compounds. In most cases, these deposits have led to a loss of production capability, in some cases, to the point that melter operation could not continue. HLW nuclear waste vitrification facilities in the United States are the Department of Energy`s Defense Waste Processing Facility (DWPF) at the Savannah River Site, the planned Hanford Waste Vitrification Plant (HWVP) at the Hanford Site and the operating West Valley Demonstration Project (WVDP) at West Valley, NY. The Integrated DWPF Melter System (IDMS) is a vitrification test facility at the Savannah River Technology Center (SRTC). It was designed and constructed to provide an engineering-scale representation of the DWPF melter and its associated feed preparation and off-gas treatment systems. An extensive noble metals testing program was begun in 1990. The objectives of this task were to explore the effects of the noble metals on the DWPF melter feed preparation and waste vitrification processes. This report focuses on the vitrification portion of the test program.

Smith, M.E. [Westinghouse Savannah River Company, AIKEN, SC (United States); Bickford, D.F.

1997-11-30T23:59:59.000Z

436

Fusion systems of -type  

Science Journals Connector (OSTI)

We prove results on 2-fusion systems related to the 2-fusion systems of groups of Lie type over the field of order 2 and certain sporadic groups. The results are used in a later paper to determine the N-systems: the 2-fusion systems of N-groups.

Michael Aschbacher

2013-01-01T23:59:59.000Z

437

SYSTEM DESIGN Lessons Learned  

E-Print Network (OSTI)

· 48% Efficiency PREREFORMER ZNO HDS TURBO EXPANDER FUEL CONDENSER FUEL EXHAUST H2 FUEL H2 A C FUEL Cell Systems High Power Shipboard System 625kW SSFC Demo 45-50% Efficient System Low Power High EfficiencyLow Power, High Efficiency Tactical Power System · Enable 3X improvement in Ship Service Fuel Cell

438

Space System Architecture  

E-Print Network (OSTI)

Final Report of SSPARC: the Space Systems, Policy, and Architecture Research Consortium (Thrust II and III)

McManus, Dr. Hugh

439

Medical imaging systems  

DOE Patents (OSTI)

A medical imaging system provides simultaneous rendering of visible light and diagnostic or functional images. The system may be portable, and may include adapters for connecting various light sources and cameras in open surgical environments or laparascopic or endoscopic environments. A user interface provides control over the functionality of the integrated imaging system. In one embodiment, the system provides a tool for surgical pathology.

Frangioni, John V

2013-06-25T23:59:59.000Z

440

Mission Operations & Data Systems  

E-Print Network (OSTI)

Mission Operations & Data Systems The LASP Mission Operations & Data Systems (MO&DS) group staffs and instruments. Operational software acts like the health systems in a body, ensuring that temperature, energy. The software monitors the health of on-board systems; anything unusual is flagged and sent to mission operators

Mojzsis, Stephen J.

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

NREL: Systems Engineering - 2015 Wind Energy Systems Engineering...  

NLE Websites -- All DOE Office Websites (Extended Search)

Systems Engineering Wind Research Systems Engineering Printable Version 2015 Wind Energy Systems Engineering Workshop The third NREL Wind Energy Systems Engineering Workshop will...

442

FNAL system patching design  

SciTech Connect

FNAL has over 5000 PCs running either Linux or Windows software. Protecting these systems efficiently against the latest vulnerabilities that arise has prompted FNAL to take a more central approach to patching systems. Due to different levels of existing support infrastructures, the patching solution for linux systems differs from that of windows systems. In either case, systems are checked for vulnerabilities by Computer Security using the Nessus tool.

Schmidt, Jack; Lilianstrom, Al; Romero, Andy; Dawson, Troy; Sieh, Connie; /Fermilab

2004-01-01T23:59:59.000Z

443

ELECTRICAL ENERGY SYSTEMS ELECTRICAL ENERGY SYSTEMS  

E-Print Network (OSTI)

. In its Energy Policy, the Scottish Government stated that it is Scotland's ambition to become a worldMEng ELECTRICAL ENERGY SYSTEMS #12;MEng ELECTRICAL ENERGY SYSTEMS Electrical energy is vital aspects of modern life. One of the biggest challenges facing society is the need for reliable energy

Strathclyde, University of

444

EPICS system: system structure and user interface  

SciTech Connect

This paper present the user's view of and the general organization of the EPICS control system at Fermilab. Various subsystems of the EPICS control system are discussed. These include the user command language, software protection, the device database, remote computer interfaces, and several application utilities. This paper is related to two other papers on EPICS: an overview paper and a detailed implementation paper.

West, R.E.; Bartlett, J.F.; Bobbitt, J.S.; Lahey, T.E.; Kramper, B.J.; MacKinnon, B.A.

1984-02-01T23:59:59.000Z

445

Renovating Residential HVAC Systems HVAC Systems  

E-Print Network (OSTI)

- 1 - LBNL 57406 Renovating Residential HVAC Systems HVAC Systems J.A. McWilliams and I.S. Walker and Air Conditioning), and Stacy Hunt and Ananda Harzell (IBACOS). #12;- 3 - Renovating Residential HVAC Guideline for Residential HVAC Retrofits (http

446

AUTONOMOUS ROBOTIC INSPECTION EXPERIMENTAL SYSTEM  

SciTech Connect

This document contains appendices on these topics: COMPUTERS AND CONTROLS; COMPUTER VISION SYSTEM; ELECTRICAL SYSTEMS; MECHANICAL SYSTEMS; ROBOTIC VEHICLE SYSTEMS; FIELD TRIALS.

David N. Rocheleau, Senior Investigator; Edward A. Hamilton, Associate Director, SCUREF; Jerry L. Hudgins, Senior Investigator; Paul McCarty, Graduate Research Assistant; Robert J. Schalkoff, Senior Investigator; Robert O. Pettus, Project Manager & Principal Investigator

1998-08-01T23:59:59.000Z

447

System Design | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

System Design System Design This template is used to define the system design System Design More Documents & Publications Transition Plan Training Plan Feasibility Study Report...

448

ENGO 431 AYMAN HABIB ENGO 431 Sample Questions: Chapters 1-4  

E-Print Network (OSTI)

is meant by a "Blackbody"? What are the factors that affect its conversion of absorbed heat into radiant examples of such systems used in remote sensing applications. What type of EM radiation each system (in your examples) uses? 25. What are the main uses of Radio waves in remote sensing? 26. What do

Habib, Ayman

449

An on-line human signature verification system  

E-Print Network (OSTI)

image Voice print Signature recognition Single- node Price (includes hardware) $1, 500 $1, 200 $2, 150 $5, 000 $55, 000* $1, 200 $1, 000 Pros Easy, fast, one of the least expensive methods Inexpensive, very secure Tiny storage... state Sample target Industries General Law enforcement, corporate databases Manufacturing/sh op floors Nuclear facilities, medical services, correctional institutions Sites requiring ultra high security Remote banking, remote database...

Simsek, Burc A

2000-01-01T23:59:59.000Z

450

Environmental Management System  

NLE Websites -- All DOE Office Websites (Extended Search)

Management System Management System Environmental Management System An Environmental Management System is a systematic method for assessing mission activities, determining the environmental impacts of those activities, prioritizing improvements, and measuring results. May 30, 2012 The continuous improvement cycle Our Environmental Management System encourages continuous improvement of our environmental performance. Contact Environmental Communication & Public Involvement P.O. Box 1663 MS M996 Los Alamos, NM 87545 (505) 667-0216 Email Managing our effects on the environment We are committed to protecting the environment while conducting our national security and energy-related missions. Laboratory Environmental Governing Policy What is the Environmental Management System? It covers every program in the Laboratory

451

Standard-C hydrogen monitoring system, system design description  

SciTech Connect

Standard-C cabinet arrangement system design description for the Standard Hydrogen Monitoring System.

Schneider, T.C., Westinghouse Hanford

1996-08-29T23:59:59.000Z

452

Fiscal system analysis â?? contractual systems  

Science Journals Connector (OSTI)

Production sharing contracts are one of the most popular forms of contractual system used in petroleum agreements around the world, but the manner in which the fiscal terms and contract parameters impact system measures is complicated and not well understood. The purpose of this paper is to quantify the influence of private and market uncertainty in contractual fiscal systems. A meta-modelling approach is employed that couples the results of a simulation model with regression analysis to construct numerical functionals that quantify the fiscal regime. Relationships are derived that specify how the present value, rate of return, and take statistics vary as a function of the system parameters. The deepwater Girassol field development in Angola is taken as a case study.

Mark J. Kaiser

2006-01-01T23:59:59.000Z

453

Electricity Distribution System Workshop  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Discussion Summary Discussion Summary Electricity Transmission System Workshop 1 Grid Tech Team Discussion Summary Electricity Transmission System Workshop 2 Table of Contents INTRODUCTION ............................................................................................................................................. 3 EXECUTIVE SUMMARY .................................................................................................................................. 4 Process ...................................................................................................................................................... 4 Synthesized Challenges ............................................................................................................................. 5

454

Supply Systems Analyst  

Energy.gov (U.S. Department of Energy (DOE))

In this position you will serve as a Supply Systems Analyst for Supply Chain Services. The incumbent is responsible for managing and supporting multiple electronic database systems, including Asset...

455

Insulation Monitoring Systems  

Science Journals Connector (OSTI)

In this chapter there is presented general information on insulation deterioration signalization systems for AC IT networks. Few systems of continuous insulation supervision are described. The old concepts includ...

Piotr Olszowiec

2013-01-01T23:59:59.000Z

456

Modular optical detector system  

DOE Patents (OSTI)

A modular optical detector system. The detector system is designed to detect the presence of molecules or molecular species by inducing fluorescence with exciting radiation and detecting the emitted fluorescence. Because the system is capable of accurately detecting and measuring picomolar concentrations it is ideally suited for use with microchemical analysis systems generally and capillary chromatographic systems in particular. By employing a modular design, the detector system provides both the ability to replace various elements of the detector system without requiring extensive realignment or recalibration of the components as well as minimal user interaction with the system. In addition, the modular concept provides for the use and addition of a wide variety of components, including optical elements (lenses and filters), light sources, and detection means, to fit particular needs.

Horn, Brent A. (Livermore, CA); Renzi, Ronald F. (Tracy, CA)

2006-02-14T23:59:59.000Z

457

Oxford System 400  

NLE Websites -- All DOE Office Websites (Extended Search)

Oxford Plasmalab System 400 Sputtering System For questions concerning this machines capabilities, please contact Varshni Singh, at 578-0248. ecr.jpg (48456 bytes)  : ecr1.jpg...

458

Design of assembly systems  

Science Journals Connector (OSTI)

The success of any assembly system depends on the translation of its design into an implemented working facility. The purpose of this chapter is to describe and explain the system elements and how they are com...

Shimon Y. Nof; Wilbert E. Wilhelm; Hans-Jürgen Warnecke

1997-01-01T23:59:59.000Z

459

Energy systems transformation  

Science Journals Connector (OSTI)

Energy systems transformation 10...associated with the incumbent energy economy that is unlikely to...its gatekeepers, such as auditors, analysts, debt-rating...problems generated by the energy system became more visible...

A. T. C. Jérôme Dangerman; Hans Joachim Schellnhuber

2013-01-01T23:59:59.000Z

460

Solar powered desalination system  

E-Print Network (OSTI)

17 1.2.4 Reverse Osmosis…………………………………………………19 1.345 Chapter 2: Reverse Osmosis System…………………………………………………….46 2.1 Reverse Osmosis System Set Up…………………………………………….46 2.2

Mateo, Tiffany Alisa

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Residential Geothermal Systems Credit  

Energy.gov (U.S. Department of Energy (DOE))

A resident individual taxpayer of Montana who installs a geothermal heating or cooling system in their principal dwelling can claim a tax credit based on the installation costs of the system, not...

462

Crowd-powered systems  

E-Print Network (OSTI)

Crowd-powered systems combine computation with human intelligence, drawn from large groups of people connecting and coordinating online. These hybrid systems enable applications and experiences that neither crowds nor ...

Bernstein, Michael Scott

2012-01-01T23:59:59.000Z

463

Systems Analysis Workshop Agenda  

Energy.gov (U.S. Department of Energy (DOE))

Agenda from DOE Systems Analysis Workshop held in Washington, D.C. July 28-29, 2004 to discuss and define role of systems analysis in DOE Hydrogen Program.

464

Energy systems transformation  

Science Journals Connector (OSTI)

...Energy System. The alternative energy system comprises solar, wind, geothermal, and hydro energy; among its associated technologies...lock-in effects. Also, rising costs caused by scarcity of energy sources or expensive and proliferating...

A. T. C. Jérôme Dangerman; Hans Joachim Schellnhuber

2013-01-01T23:59:59.000Z

465

Automobile Electrical Systems  

Science Journals Connector (OSTI)

The modern electrical system has been developed, over a period of some fifty years from the days of the early motor-car which usually had only one electrical system, namely, that of the ignition comp...

Arthur W. Judge

1970-01-01T23:59:59.000Z

466

Evolution of Web Systems  

Science Journals Connector (OSTI)

The World Wide Web has led to a new kind of software, web systems, which are based on web technologies. Just like software in other domains, web systems have evolution challenges. This chapter discusses evolution...

Holger M. Kienle; Damiano Distante

2014-01-01T23:59:59.000Z

467

Fuel washout detection system  

DOE Patents (OSTI)

A system for detecting grossly failed reactor fuel by detection of particulate matter as accumulated on a filter.

Colburn, Richard P. (Pasco, WA)

1985-01-01T23:59:59.000Z

468

Performance Tested Comfort Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Showerheads Residential Weatherization Performance Tested Comfort Systems Ductless Heat Pumps New Construction Residential Marketing Toolkit Retail Sales Allocation Tool...

469

Monitoring System Performance (Presentation)  

SciTech Connect

Requirements for a standard test to rate the durability of photovoltaic (PV) modules at system voltage are discussed.

Emery, K.; Smith, R.

2011-02-01T23:59:59.000Z

470

Energy Storage Systems  

SciTech Connect

Energy Storage Systems – An Old Idea Doing New Things with New Technology article for the International Assoication of ELectrical Inspectors

Conover, David R.

2013-12-01T23:59:59.000Z

471

Directives System Manual  

Directives, Delegations, and Requirements

This Manual provides detailed requirements to supplement DOE O 251.1A, Directives System, dated 1-30-98.

1998-01-30T23:59:59.000Z

472

Enhanced Geothermal Systems  

Energy.gov (U.S. Department of Energy (DOE))

Below are the project presentations and respective peer review results for Engineered Geothermal Systems, Low Temperature and Exploration Demonstration Projects.

473

Match Pumps to System Requirements  

SciTech Connect

BestPractices Program tip sheet discussing pumping system efficiency matching pumps to system requirements

Not Available

2005-10-01T23:59:59.000Z

474

DOE Systems Engineering Methodology  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Computer System Retirement Guidelines Computer System Retirement Guidelines Version 3 September 2002 U.S. Department of Energy Office of the Chief Information Officer Computer System Retirement Guidelines Date: September 2002 Page 1 Rev Date: Table of Contents Section Page Purpose ............................................................................................................................................ 2 Initiation and Distribution ............................................................................................................... 2 Resource .......................................................................................................................................... 2 General Information ........................................................................................................................

475

On Analogue TMR System  

Science Journals Connector (OSTI)

This chapter presents a reliability model of the TMR Triple Modular Redundancy system based on analogue measurement channels. While reliability modelling of the standard TMR system based on digital channels has been well described in many previous publications, ... Keywords: Fault Detection Voter FDV, Fault-Tolerant System, Redundancy, Reliability, Triple Modular Redundancy TMR

Pavel Kucera

2012-10-01T23:59:59.000Z

476

Energy Systems Laboratory Groundbreaking  

ScienceCinema (OSTI)

INL recently broke ground for a research facility that will house research programs for bioenergy, advanced battery systems, and new hybrid energy systems that integrate renewable, fossil and nuclear energy sources. Here's video from the groundbreaking ceremony for INL's new Energy Systems Laboratory. You can learn more about CAES research at http://www.facebook.com/idahonationallaboratory.

Hill, David; Otter, C.L.; Simpson, Mike; Rogers, J.W.;

2013-05-28T23:59:59.000Z

477

IDC System Specification Document.  

SciTech Connect

This document contains the system specifications derived to satisfy the system requirements found in the IDC System Requirements Document for the IDC Reengineering Phase 2 project. Revisions Version Date Author/Team Revision Description Authorized by V1.0 12/2014 IDC Reengineering Project Team Initial delivery M. Harris

Clifford, David J.

2014-12-01T23:59:59.000Z

478

SYSTEM SAFETY PROGRESS REPORT,  

E-Print Network (OSTI)

SYSTEM SAFETY PROGRESS REPORT, ALSEP Array E NO. ATM 1034 1 PAGE REV. NO. OF 3 DATE 26 July 1971 This A TM documents the progress of the System Safety Program for ALSEP Array E. -~/ Prepared by: · /~t:A~.., Approved by: W. · Lavin, Jr System Safety Engineer / /' J. P. ~/ es, Supervisor · , ALSEF Support

Rathbun, Julie A.

479

Plane waves Lumped systems  

E-Print Network (OSTI)

1 Impedance · Plane waves ­ Lumped systems S x y z Impedance · Plane waves ­ Lumped systems · open tube #12;2 Impedance · Plane waves ­ Lumped systems · closed tube Impedance · Cylindrical waves z x y r #12;3 Impedance · Cylindrical waves ­ Circumferential part n=0 n=1 n=2 n=3 Impedance · Cylindrical

Berlin,Technische Universität

480

Transforming our information systems  

E-Print Network (OSTI)

Transforming our information systems and technology Information Systems Development Framework #12 university. In support of this position we are transforming our information systems, servicesDonald Principal and Vice-Chancellor #12;Strategy for transformation Tactical Delivering the services and tools our

Strathclyde, University of

Note: This page contains sample records for the topic "radiant floor systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Operating System Resource Management  

E-Print Network (OSTI)

Operating System Resource Management Date: Monday, September 27, 2010 Time: 2:00 ­ 3:00 pm Location allocation and de-allocation by an operating system of processor cores, memory pages, and various types constrained. This talk will propose a scheme for addressing the operating system resource management problem

482

Offshore wind energy systems  

Science Journals Connector (OSTI)

Wind energy systems deployed in the shallow but windy waters of the southern North Sea have the potential to provide more than 20% of UK electricity needs. With existing experience of windmills, and of aircraft and offshore structures, such wind energy systems could be developed within a relatively short timescale. A preliminary assessment of the economics of offshore wind energy systems is encouraging.

P Musgrove

1978-01-01T23:59:59.000Z

483

Memory Systems Doug Burger  

E-Print Network (OSTI)

Memory Systems Doug Burger University of Wisconsin-Madison A computer's memory system and produces. A perfect memory system is one that can supply immediately any datum that the CPU requests. This ideal memory is not practically implementable, however, as the three factors of memory capacity, speed

Burger, Doug

484

Development and Application of Laser Peening System for PWR Power Plants  

SciTech Connect

Laser peening is a process to improve residual stress from tensile to compressive in surface layer of materials by irradiating high-power laser pulses on the material in water. Toshiba has developed a laser peening system composed of Q-switched Nd:YAG laser oscillators, laser delivery equipment and underwater remote handling equipment. We have applied the system for Japanese operating BWR power plants as a preventive maintenance measure for stress corrosion cracking (SCC) on reactor internals like core shrouds or control rod drive (CRD) penetrations since 1999. As for PWRs, alloy 600 or 182 can be susceptible to primary water stress corrosion cracking (PWSCC), and some cracks or leakages caused by the PWSCC have been discovered on penetrations of reactor vessel heads (RVHs), reactor bottom-mounted instrumentation (BMI) nozzles, and others. Taking measures to meet the unconformity of the RVH penetrations, RVHs themselves have been replaced in many PWRs. On the other hand, it's too time-consuming and expensive to replace BMI nozzles, therefore, any other convenient and less expensive measures are required instead of the replacement. In Toshiba, we carried out various tests for laser-peened nickel base alloys and confirmed the effectiveness of laser peening as a preventive maintenance measure for PWSCC. We have developed a laser peening system for PWRs as well after the one for BWRs, and applied it for BMI nozzles, core deluge line nozzles and primary water inlet nozzles of Ikata Unit 1 and 2 of Shikoku Electric Power Company since 2004, which are Japanese operating PWR power plants. In this system, laser oscillators and control devices were packed into two containers placed on the operating floor inside the reactor containment vessel. Laser pulses were delivered through twin optical fibers and irradiated on two portions in parallel to reduce operation time. For BMI nozzles, we developed a tiny irradiation head for small tubes and we peened the inner surface around J-groove welds after laser ultrasonic testing (LUT) as the remote inspection, and we peened the outer surface and the weld for Ikata Unit 2 supplementary. For core deluge line nozzles and primary water inlet nozzles, we peened the inner surface of the dissimilar metal welding, which is of nickel base alloy, joining a safe end and a low alloy metal nozzle. In this paper, the development and the actual application of the laser peening system for PWR power plants will be described. (authors)

Masaki Yoda; Itaru Chida; Satoshi Okada; Makoto Ochiai; Yuji Sano; Naruhiko Mukai; Gaku Komotori; Ryoichi Saeki [Toshiba Corporation (Japan); Toshimitsu Takagi; Masanori Sugihara; Hirokata Yoriki [Shikoku Electric Co., Inc. (Japan)

2006-07-01T23:59:59.000Z

485

MANAGEMENT CONTROL SYSTEM IN PUBLIC  

E-Print Network (OSTI)

1 MANAGEMENT CONTROL SYSTEM IN PUBLIC ADMINISTRATION: BEYOND RATIONAL MYTHS Nicolas Berland of practices around their management control systems. Despite some apparent failures, the implemented systems organizations have developed management control systems. Historically, these systems have been invented

Paris-Sud XI, Université de

486

Distribution System Research Priorities  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mark McGranaghan Mark McGranaghan EPRI ELECTRICITY DISTRIBUTION SYSTEM WORKSHOP Crystal City, VA September 24, 2012 Distribution System Research Priorities 2 © 2012 Electric Power Research Institute, Inc. All rights reserved. The Power System Roadmaps start with a Vision Future Power System will require new technologies, infrastructure, and control systems 3 © 2012 Electric Power Research Institute, Inc. All rights reserved. R&D Roadmaps - Coordination is Critical Roadmaps are living documents 4 © 2012 Electric Power Research Institute, Inc. All rights reserved. Developing the next generation grid * Industry needs new technologies, communication protocols, and information management methods - More variable generation sources and controllable loads - Aging infrastructure

487

FRIB cryogenic distribution system  

SciTech Connect

The Michigan State University Facility for Rare Isotope Beams (MSU-FRIB) helium distribution system has been revised to include bayonet/warm valve type disconnects between each cryomodule and the transfer line distribution system, similar to the Thomas Jefferson National Accelerator Facility (JLab) and the Spallation Neutron Source (SNS) cryogenic distribution systems. The heat loads at various temperature levels and some of the features in the design of the distribution system are outlined. The present status, the plans for fabrication, and the procurement approach for the helium distribution system are also included.

Ganni, Venkatarao [JLAB; Dixon, Kelly D. [JLAB; Laverdure, Nathaniel A. [JLAB; Knudsen, Peter N. [JLAB; Arenius, Dana M. [JLAB; Barrios, Matthew N. [Michigan State; Jones, S. [Michigan State; Johnson, M. [Michigan State; Casagrande, Fabio [Michigan State

2014-01-01T23:59:59.000Z

488

FRIB cryogenic distribution system  

SciTech Connect

The Michigan State University Facility for Rare Isotope Beams (MSU-FRIB) helium distribution system has been revised to include bayonet/warm valve type disconnects between each cryomodule and the transfer line distribution system, similar to the Thomas Jefferson National Accelerator Facility (JLab) and the Spallation Neutron Source (SNS) cryogenic distribution systems. The heat loads at various temperature levels and some of the features in the design of the distribution system are outlined. The present status, the plans for fabrication, and the procurement approach for the helium distribution system are also included.

Ganni, V.; Dixon, K.; Laverdure, N.; Knudsen, P.; Arenius, D. [Thomas Jefferson National Accelerator Facility (JLab), Newport News, VA 23606 (United States); Barrios, M.; Jones, S.; Johnson, M.; Casagrande, F. [Facility for Rare Isotope Beams (FRIB), Michigan State University, East Lansing, MI 48824 (United States)

2014-01-29T23:59:59.000Z

489

Business System Planning Project, Preliminary System Design  

SciTech Connect

CH2M HILL Hanford Group, Inc. (CHG) is currently performing many core business functions including, but not limited to, work control, planning, scheduling, cost estimating, procurement, training, and human resources. Other core business functions are managed by or dependent on Project Hanford Management Contractors including, but not limited to, payroll, benefits and pension administration, inventory control, accounts payable, and records management. In addition, CHG has business relationships with its parent company CH2M HILL, U.S. Department of Energy, Office of River Protection and other River Protection Project contractors, government agencies, and vendors. The Business Systems Planning (BSP) Project, under the sponsorship of the CH2M HILL Hanford Group, Inc. Chief Information Officer (CIO), have recommended information system solutions that will support CHG business areas. The Preliminary System Design was developed using the recommendations from the Alternatives Analysis, RPP-6499, Rev 0 and will become the design base for any follow-on implementation projects. The Preliminary System Design will present a high-level system design, providing a high-level overview of the Commercial-Off-The-Shelf (COTS) modules and identify internal and external relationships. This document will not define data structures, user interface components (screens, reports, menus, etc.), business rules or processes. These in-depth activities will be accomplished at implementation planning time.

EVOSEVICH, S.

2000-10-30T23:59:59.000Z

490

E-Print Network 3.0 - access indoor wireless Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Computer Technologies and Information Sciences 2 Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture Summary: that multiple floors can be served via the...

491

LM Records Handling System-Fernald Historical Records System...  

NLE Websites -- All DOE Office Websites (Extended Search)

Fernald Historical Records System, Office of Legacy Management LM Records Handling System-Fernald Historical Records System, Office of Legacy Management LM Records Handling...

492

OPERATING SYSTEM CONCEPTS Avi Silberschatz  

E-Print Network (OSTI)

OPERATING SYSTEM CONCEPTS Avi Silberschatz Department of Computer Sciences University of Texas & Peter Galvin CHAPTER 1: INTRODUCTION . What is an operating system? . Early Systems . Simple Batch Systems . Distributed Systems . Real­Time Systems Operating System Concepts, Addison­Wesley � 1994

Schmidt, Douglas C.

493

NEWTON's Metric System Resources  

NLE Websites -- All DOE Office Websites (Extended Search)

Please select any link below. Search this page, using your web browser's search function. Please select any link below. Search this page, using your web browser's search function. Metric System References Do you have a great metric reference link? Please click our Ideas page. Featured Reference Links: Metric (SI) References Metric (SI) References Having trouble with the metric system? Visit the National Institute of Standards and Technology's site about the rules and style conventions of the International System of Units (SI). The Metric System The Metric System Need another reference? Try this site provided by Wikipedia that discusses the metric system and its history in depth. Metric Converter Metric Converter Need to convert to Metric? OnlineConversion.com allows you to convert just about anything to just about anything else. This will let you easily from metric to US Standard notation, and vice versa.

494

Idaho Explosives Detection System  

SciTech Connect

The Idaho Explosives Detection System was developed at the Idaho National Laboratory (INL) to respond to threats imposed by delivery trucks potentially carrying explosives into military bases. A full-scale prototype system has been built and is currently undergoing testing. The system consists of two racks, one on each side of a subject vehicle. Each rack includes a neutron generator and an array of NaI detectors. The two neutron generators are pulsed and synchronized. A laptop computer controls the entire system. The control software is easily operable by minimally trained staff. The system was developed to detect explosives in a medium size truck within a 5-min measurement time. System performance was successfully demonstrated with explosives at the INL in June 2004 and at Andrews Air Force Base in July 2004.

Edward L. Reber; Larry G. Blackwood; Andrew J. Edwards; J. Keith Jewell; Kenneth W. Rohde; Edward H. Seabury; Jeffery B. Klinger

2005-12-01T23:59:59.000Z

495

Heating and cooling system  

SciTech Connect

Heating and cooling of dwelling houses and other confined spaces is facilitated by a system in which thermal energy is transported between an air heating and cooling system in the dwelling and a water heat storage sink or source, preferably in the form of a swimming pool or swimming pool and spa combination. Special reversing valve circuitry and the use of solar collectors and liquid-to-liquid heat exchangers on the liquid side of the system , and special air valves and air modules on the air side of the system, enhance the system's efficiency and make it practical in the sense that systems employing the invention can utilize existing craft skills and building financing arrangements and building codes, and the like, without major modification.

Krumhansl, M.U.

1982-10-12T23:59:59.000Z

496

Oxidative Tritium Decontamination System  

SciTech Connect

The Princeton Plasma Physics Laboratory, Tritium Systems Group has developed and fabricated an Oxidative Tritium Decontamination System (OTDS), which is designed to reduce tritium surface contamination on various components and items. The system is configured to introduce gaseous ozone into a reaction chamber containing tritiated items that require a reduction in tritium surface contamination. Tritium surface contamination (on components and items in the reaction chamber) is removed by chemically reacting elemental tritium to tritium oxide via oxidation, while purging the reaction chamber effluent to a gas holding tank or negative pressure HVAC system. Implementing specific concentrations of ozone along with catalytic parameters, the system is able to significantly reduce surface tritium contamination on an assortment of expendable and non-expendable items. This paper will present the results of various experimentation involving employment of this system.

Charles A. Gentile; John J. Parker; Gregory L. Guttadora; Lloyd P. Ciebiera

2002-02-11T23:59:59.000Z

497

NSLS Computer Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Computer Systems Computer Systems Micro Systems WorkStation Applications Network Configuration Documents The National Synchrotron Light Source facility at the Brookhaven National Laboratory in New York, consists of two storage rings, one for VUV operating at 800 Mev and one for XRAY at 2.8 Gev and a common injection system comprised of a linear accelerator and a Booster ring. Hardware Architecture The hardware architecture of the present control system follows the current trend seen in many accelerator facilities. It is a two-level distributed system consisting of HP/900 series workstations connected by the standard ethernet to VME-based microprocessor subsystems. All the workstations have local disk and sufficient memory for fast response. Workstations are used as file server, back-up file server and for program development and other

498

Elec 331 -Nervous System Nervous System  

E-Print Network (OSTI)

Left Atrium Right Atrium AV Node Time delay Automaticity · SA Node ­ 70-100 BPM · AV Node ­ 40-60 BPM · Remainder ­ 15-40 BPM #12;Elec 331 - Nervous System 5 Cardiac Vector · When viewed from far away: ­ Sum

Pulfrey, David L.

499

Building America System Research  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Building America System Building America System Research Eric Werling, DOE Ren Anderson, NREL eric.werling@ee.doe.gov, 202-586-0410 ren.anderson@nrel.gov, 303-384-7443 April 2, 2013 Building America System Innovations: Accelerating Innovation in Home Energy Savings 2 | Program Name or Ancillary Text eere.energy.gov Project Relevance 3 | Building Technologies Office eere.energy.gov Building America Fills Market Need for a High-Performance Homes HUB of Innovation

500

Corrosion consultant expert system  

SciTech Connect

The development and use of an expert system to recommend coatings for flue gas desulfurization (FGD) plant is described. The system ranks coatings by their material properties, experimental test and plant performance scores when the component to be coated and its working environment are specified. The user interface, the inference engine, the knowledge base and the implementation of the expert system are presented with comments on its suitability and application for corrosion consultations.

Mo, Y.L. [National Cheng Kung Univ., Tainan (Taiwan, Province of China)

1994-12-31T23:59:59.000Z