Powered by Deep Web Technologies
Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

(Quality control and nondestructive test procedures for welded products)  

SciTech Connect (OSTI)

The International Institute of Welding is composed of some 600 technical experts from 36 countries. These individuals are divided by talent and personal interest into fifteen separate groups called Commissions, each with its own charter and goals. The title, and by inference the charter, of Commission V is : Quality Control and Quality Assurance of Welded Products. In pursuit of its charter Commission V has several subcommissions engaged in the development of drafts, procedures, and standards. Those documents subsequently considered suitable may be submitted to the International Organization for Standards (ISO), an organization similar to the American Society for Testing Materials, for acceptance as international standards. All ISO Procedures and standards which have been in effect for five years must undergo review by the initiating body. The results from review of five-year-old standards and procedures and the discussion of other documents proposed for international publication are presented.

Childress, C.E.

1990-11-09T23:59:59.000Z

2

A suite of RS/1 procedures for chemical laboratory statistical quality control and Shewhart control charting  

SciTech Connect (OSTI)

A suite of RS/1 procedures for Shewhart control charting in chemical laboratories is described. The suite uses the RS series product QCA (Quality Control Analysis) for chart construction and analysis. The suite prompts users for data in a user friendly fashion and adds the data to or creates the control charts. All activities are time stamped. Facilities for generating monthly or contiguous time segment summary charts are included. The suite is currently in use at Westinghouse Savannah River Company.

Shanahan, K.L.

1990-09-01T23:59:59.000Z

3

Data Driven Quality Assurance and Quality Control  

Broader source: Energy.gov [DOE]

"Data Driven Quality Assurance & Quality Control," Patrick Roche, Conservation Services Group. Provides an overview of data QA/QC system design.

4

Alternative Fuels Data Center: Biodiesel Quality Testing Procedures  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Biodiesel Quality Biodiesel Quality Testing Procedures to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Quality Testing Procedures on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Quality Testing Procedures on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Quality Testing Procedures on Google Bookmark Alternative Fuels Data Center: Biodiesel Quality Testing Procedures on Delicious Rank Alternative Fuels Data Center: Biodiesel Quality Testing Procedures on Digg Find More places to share Alternative Fuels Data Center: Biodiesel Quality Testing Procedures on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Biodiesel Quality Testing Procedures Each biodiesel or other renewable diesel producer, distributor, or importer

5

Chapter 50 Division for Air Quality: General Administrative Procedures  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Chapter 50 Division for Air Quality: General Administrative Procedures (Kentucky) Chapter 50 Division for Air Quality: General Administrative Procedures (Kentucky) < Back Eligibility Agricultural Commercial Construction Developer Fuel Distributor General Public/Consumer Industrial Installer/Contractor Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Transportation Utility Program Info State Kentucky Program Type Environmental Regulations Provider Kentucky Department for Environmental Protection Chapter 50 of the Division of Air Quality section within Energy and Environment Cabinet Department For Environmental Protection outlines the general administrative procedures for maintaining air quality standards. These procedures are created in adherence to 42 USC 7410 which requires the

6

CONTROL VALVE TESTING PROCEDURES AND EQUATIONS  

E-Print Network [OSTI]

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS #12;APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS 2 Cv Q P Sg net gpm net = / Cv = Q P / Sg 75 in this report is per Instrument Society of America S39.2 testing specifications for control valves. The main

Rahmeyer, William J.

7

Quality Assurance Procedures in the Oklahoma Mesonetwork  

Science Journals Connector (OSTI)

High quality data sources are critical to scientists, engineers, and decision makers alike. The models that scientists develop and test with quality-assured data eventually become used by a wider community, from policy makers’ long-term ...

Mark A. Shafer; Christopher A. Fiebrich; Derek S. Arndt; Sherman E. Fredrickson; Timothy W. Hughes

2000-04-01T23:59:59.000Z

8

Water Quality Control (Texas)  

Broader source: Energy.gov [DOE]

The policy of the state of Texas is to promote the quality of the state's water by regulating existing industries, taking into consideration the economic development of the state, and by...

9

EERE Quality Control Workshop Agenda  

Broader source: Energy.gov [DOE]

Agenda from the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy (EERE) Quality Control Workshop held December 9-10, 2013, at the National Renewable Energy Laboratory in Golden, Colorado.

10

Evaluation of the Indoor Air Quality Procedure for Use in Retail Buildings  

E-Print Network [OSTI]

to the ASHRAE 62.1 Indoor Air Quality Procedure. LawrenceEvaluation of the Indoor Air Quality Procedure for Use innon-prescriptive “indoor air quality procedure” (IAQP). The

Dutton, Spencer M.

2014-01-01T23:59:59.000Z

11

Quality assurance of solar thermal systems with the ISFH-Input/Output-Procedure  

E-Print Network [OSTI]

. Supplementary sensors may be necessary for some special solar systems (e. g. solar systems with several storagesQuality assurance of solar thermal systems with the ISFH- Input/Output-Procedure Peter Paerisch/Output-Controllers for in situ and automatic function control of solar thermal systems that were developed within the research

12

Procedure for Generating Data Quality Reports for SIRS Radiometric Measurements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Procedure for Generating Data Quality Reports Procedure for Generating Data Quality Reports for SIRS Radiometric Measurements M. H. L. Anderberg, F. P. Rael, and T. L. Stoffell National Renewable Energy Laboratory Golden, Colorado Introduction The Atmospheric Radiation Measurement (ARM) Program needs high-quality broadband shortwave (SW) (solar) and longwave (LW) irradiance information for the development and validation of atmospheric circulation and climate models. To this end, the National Renewable Energy Laboratory (NREL) performs a quality assessment of the data from 22 Solar Infrared Stations (SIRS) in the Southern Great Plains (SGP). Data quality reports (DQRs) are instrumental in passing the resultant information to the scientific community. The value of these reports depends on clear and consistent

13

EERE Quality Control Workshop | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Quality Control Workshop EERE Quality Control Workshop The U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory (NREL) held the Office of Energy Efficiency and...

14

Quality Assurance Procedures for ModCat Database Code Files  

SciTech Connect (OSTI)

The Quality Assurance procedures used for the initial phase of the Model Catalog Project were developed to attain two objectives, referred to as “basic functionality” and “visualization.” To ensure the Monte Carlo N-Particle model input files posted into the ModCat database meet those goals, all models considered as candidates for the database are tested, revised, and re-tested.

Siciliano, Edward R.; Devanathan, Ram; Guillen, Zoe C.; Kouzes, Richard T.; Schweppe, John E.

2014-04-01T23:59:59.000Z

15

Performance of Quality Assurance Procedures on Daily Precipitation  

Science Journals Connector (OSTI)

The search for precipitation quality control (QC) methods has proven difficult. The high spatial and temporal variability associated with precipitation data causes high uncertainty and edge creep when regression-based approaches are applied. ...

Jinsheng You; Kenneth G. Hubbard; Saralees Nadarajah; Kenneth E. Kunkel

2007-05-01T23:59:59.000Z

16

Fabrication procedures for HFIR control plates  

SciTech Connect (OSTI)

The HFIR control system uses Alclad cylindrically shaped components, which have regions containing 31 vol % Eu/sub 2/O/sub 3/ and 38 vol % Ta, respectively. Exacting control of the water passage between these components and adjacent reactor parts is mandatory, and precise dimensional control of the finished products is required. This report describes the procedures developed for manufacturing outer control plates and inner control cylinders. Results are cited which demonstrate that circular-shaped outer control plates can be produced with less than 0.025-in. variation from the specified 9.300-in. radius in any region of the plate. Other results show that, by the exercise of careful control, inner control, inner control plates can be welded into cylindrical geometry with diametrical variations held to less than +- 0.010 in. of the intended 17.846-in. average diam. The cylinders can then be explosively sized, while under compression, with diametric variations of less than 0.005 in. while controlling roundness variations to less than 0.030 in. from the specified 17.842-in. finished diam.

Bowden, G.A.; Hicks, G.R.; Knight, R.W.

1984-10-01T23:59:59.000Z

17

Environmental Quality Information Analysis Center (EQIAC) operating procedures handbook  

SciTech Connect (OSTI)

The Operating Procedures Handbook of the Environmental Quality Information Analysis Center (EQIAC) is intended to be kept current as EQIAC develops and evolves. Its purpose is to provide a comprehensive guide to the mission, infrastructure, functions, and operational procedures of EQIAC. The handbook is a training tool for new personnel and a reference manual for existing personnel. The handbook will be distributed throughout EQIAC and maintained in binders containing current dated editions of the individual sections. The handbook will be revised at least annually to reflect the current structure and operational procedures of EQIAC. The EQIAC provides information on environmental issues such as compliance, restoration, and environmental monitoring do the Air Force and DOD contractors.

Walsh, T.E. (Florida Univ., Gainesville, FL (United States)); Das, S. (Oak Ridge National Lab., TN (United States))

1992-08-01T23:59:59.000Z

18

Quality Control Inspector: Different Programs, Different Responsibilities  

Broader source: Energy.gov [DOE]

This document explains the role of the Quality Control Inspector (QCI) in regards to the Home Energy Professional Certification Exam.

19

Laser Controlled Area Standard Operating Procedure (SOP)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

90 90 1 Effective: Page 1 of 11 06/20/12 Subject: Laser Safety Program Documentation - Raman X18/19 Frenkel Group 3.1/2g03e011.doc 1 (02/2010) BROOKHAVEN NATIONAL LABORATORY LASER CONTROLLED AREA STANDARD OPERATING PROCEDURE (SOP) This document defines the safety management program for the laser system(s) listed below. All American National Standard Institute (ANSI) Hazard Class 3B and 4 laser systems must be documented, reviewed, and approved through use of this form. Each system must be reviewed annually. Modify the template for this document to fit your particular circumstance. System description: Raman fiber optic system with class 3B laser source Location: Currently in NSLS room 1-127, but will be utilized with beamlines X18A, X18B, and X19A

20

Laser Controlled Area Standard Operating Procedure (SOP)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

PS-ESH-0025 PS-ESH-0025 01 Effective: Page 1 of 13 03/09/2012 Subject: Laser Safety Program Documentation X17C The only official copy of this file is the one on-line in the NSLS ESH website. Before using a printed copy, verify that it is the most current version by checking the document issue date on the NSLS ESH website. BROOKHAVEN NATIONAL LABORATORY LASER CONTROLLED AREA STANDARD OPERATING PROCEDURE (SOP) X17C Laser System System description: There is one laser at X17C: Diode-Pumped Solid State Laser (Class 3B) that has two uses: - Measurement of diamond anvil pressure from ruby fluorescence - Raman spectrum measurements Location: The DPSS laser system is located in NSLS room 1-134C LINE MANAGEMENT RESPONSIBILITIES The Owner/Operator for this laser is listed below. The Owner/Operator is the Line Manager of the system

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Laser Controlled Area Standard Operating Procedure (SOP)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 3 001 Effective: Page 1 of 11/18/11 11 Subject: Laser Safety Program Documentation Bldg 703 E3/E4 3.1/2g03e011.doc 1 (02/2010) BROOKHAVEN NATIONAL LABORATORY LASER CONTROLLED AREA STANDARD OPERATING PROCEDURE (SOP) This document defines the safety management program for the laser system(s) listed below. All American National Standard Institute (ANSI) Hazard Class 3B and 4 laser systems must be documented, reviewed, and approved through use of this form. Each system must be reviewed annually. Modify the template for this document to fit your particular circumstance. System description: MOS laser curvature measurement system - Thin Film Deposition Lab Location: 703, E2/E4 LINE MANAGEMENT RESPONSIBILITIES The Owner/Operator(s) for this laser is/are listed below. The Owner/Operator is the Line Manager of the

22

Laser Controlled Area Standard Operating Procedure (SOP)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

79 79 01 Effective: Page 1 of 17 05/13/11 Subject: X17B3 Laser Safety Program Documentation 1 AUTHORIZATION | Princeton University BROOKHAVEN NATIONAL LABORATORY LASER CONTROLLED AREA STANDARD OPERATING PROCEDURE (SOP) This document defines the safety management program for the laser system listed below. All American National Standard Institute (ANSI) Hazard Class 3B and 4 laser systems must be documented, reviewed, and approved through use of this form. Each system must be reviewed annually. System description: A laser heating system for diamond anvil cell experiments has been installed at X17B3. A class 4 ytterbium fiber laser (IPG model YLR-100-SM-CS) is used to perform high-pressure laser heating of samples contained in diamond anvil cells. Included within this laser is a guide laser

23

Laser Controlled Area Standard Operating Procedure (SOP)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

72 72 2 Effective: Page 1 of 16 3/6/13 Subject: X26C Laser Safety Program Documentation The only official copy of this file is the one on-line in the Photon Sciences website. Before using a printed copy, verify that it is the most current version by checking the document issue date on the Photon Sciences website. 2.1/2g03e011.doc 1 (06/2009) BROOKHAVEN NATIONAL LABORATORY LASER CONTROLLED AREA STANDARD OPERATING PROCEDURE (SOP) This document defines the safety management program for the laser system(s) listed below. All American National Standard Institute (ANSI) Hazard Class 3B and 4 laser systems must be documented, reviewed, and approved through use of this form. Each system must be reviewed annually. Modify the template for this document to fit your particular circumstance.

24

Laser Controlled Area Standard Operating Procedure (SOP)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

6 4 6 4 Effective: Page 1 of 18 09/16/2011 Subject: Laser Safety Program Documentation: U2A The only official copy of this file is the one on-line in the PS ESH website. Before using a printed copy, verify that it is the most current version by checking the document issue date on the PS ESH website. BROOKHAVEN NATIONAL LABORATORY LASER CONTROLLED AREA STANDARD OPERATING PROCEDURE (SOP) U2A Laser Systems This document defines the safety management program for the laser system(s) listed below. All American National Standard Institute (ANSI) Hazard Class 3B and 4 laser systems must be documented, reviewed, and approved through use of this form. Each system must be reviewed annually. System description: There are 4 lasers installed at beamline U2A for diamond anvil cell experiments:

25

Laser Controlled Area Standard Operating Procedure (SOP)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

32 32 004 Effective: Page 1 of 13 12/1/10 Subject: Laser Safety Program Documentation X20C 3.1/2g03e011.doc 1 (02/2010) BROOKHAVEN NATIONAL LABORATORY LASER CONTROLLED AREA STANDARD OPERATING PROCEDURE (SOP) This document defines the safety management program for the laser system(s) listed below. All American National Standard Institute (ANSI) Hazard Class 3B and 4 laser systems must be documented, reviewed, and approved through use of this form. Each system must be reviewed annually. Modify the template for this document to fit your particular circumstance. System description: Time-resolved light scattering Location: X20C Hutch LINE MANAGEMENT RESPONSIBILITIES The Owner/Operator(s) for this laser is/are listed below. The Owner/Operator is the Line Manager of the

26

CUNY EXPORT CONTROL PROCEDURES 9. Information Technology (IT)  

E-Print Network [OSTI]

CUNY EXPORT CONTROL PROCEDURES 9. Information Technology (IT) This Section addresses the process travel with clean laptops. All IT Security Policies & Procedures are applicable when complying with CUNY in accordance with these Policies and Procedures. Technology related access restrictions and controls

Rosen, Jay

27

NREL Job Task Analysis: Quality Control Inspector  

SciTech Connect (OSTI)

A summary of job task analyses for the position of quality control inspector when evaluating weatherization work that has been done on a residence.

Kurnik, C.; Woodley, C.

2011-05-01T23:59:59.000Z

28

AIR QUALITY: Control Enters New Phase  

Science Journals Connector (OSTI)

AIR QUALITY: Control Enters New Phase ... Federal enforcement of air pollution is about to enter a new, more technically sophisticated, phase. ... Now air pollution control moves into the criteria and standards period, when numbers eventually will be the basis for enforcement and the country becomes zoned into 32 air quality regions. ...

1968-08-05T23:59:59.000Z

29

Should Title 24 Ventilation Requirements Be Amended to include an Indoor Air Quality Procedure?  

E-Print Network [OSTI]

predicted indoor air quality and energy consumption using aquality procedure (IAQP) that may result in lower VRs than the VRP, with associated energyquality procedure” (IAQP), with both objective and subjective components, intended to provide greater flexibility and potentially enable energy

Dutton, Spencer M.

2014-01-01T23:59:59.000Z

30

Software Quality Assurance Control of Existing Systems | Department...  

Office of Environmental Management (EM)

Software Quality Assurance Control of Existing Systems Software Quality Assurance Control of Existing Systems Existing software systems often represent significant investments and...

31

5 CCR 1001 - Air Quality Control | Open Energy Information  

Open Energy Info (EERE)

Quality ControlLegal Abstract Through this chapter the Colorado Department of Public Health and Environment regulates air quality control. Published NA Year Signed or Took...

32

AUTOMATIC VARIABLE VENTILATION CONTROL SYSTEMS BASED ON AIR QUALITY DETECTION  

E-Print Network [OSTI]

Control Systems Based on Air Quality Detection Isaac Turiel,HVAC CONTROL SYSTEM BASED ON AIR QUALITY SENSING To Zl)(lecontrol systems based on air quality detection Isaac Turiel,

Turiel, Isaac

2011-01-01T23:59:59.000Z

33

Analytical quality control services of the International Atomic Energy Agency  

Science Journals Connector (OSTI)

The International Atomic Energy Agency provides quality control services to analytical laboratories. These services...

O. Suschny

1986-01-01T23:59:59.000Z

34

Evaluation of the Indoor Air Quality Procedure for Use in Retail Buildings  

E-Print Network [OSTI]

and source strengths in U.S. retail stores–A pilot study.Air Quality Procedure for Use in Retail Buildings Spencer M.concentrations in a large retail store. Emmerich, S J. and A

Dutton, Spencer M.

2014-01-01T23:59:59.000Z

35

Project W-049H instrument and control Acceptance Test Procedure  

SciTech Connect (OSTI)

The purpose of this Acceptance Test Procedure (ATP) for the Project W-049H, Treated Effluent Disposal Facility, is to verify that the instrument and control systems have been installed in accordance with the design documents and function as required by the project criteria. The instrument and control system includes three operator control stations, modems, and general purpose LAN interface cabinets in the Effluent Treatment Facility control room; two pump stations; disposal station pumping building; and all local control units installed in the fold. Testing will be performed using actual signals when available and simulated signals when actual signals are unavailable.

Carrigan, M.C.

1994-11-16T23:59:59.000Z

36

A two stage procedure for control structure analysis and design  

Science Journals Connector (OSTI)

A two stage procedure for control structure analysis and design is proposed and investigated on a heatpump control structure synthesis problem. In the first stage qualitative process knowledge is used to suggest possible control structures, ie. measurements, actuators and feasible loop pairings for multiloop SISO (scalar) control. In the second stage frequency dependent SVD (Singular Value Decomposition) is employed on a quantitative model to indicate, whether a multivariable control strategy is called for. If scalar control is inferred to be adequate, the RGA (Relative Gain Array) method is used to synthesize loop pairings for multiloop SISO control. The proposed procedure is demonstrated using a heatpump control structure analysis and design problem. The heatpump is used on an industrial scale energy integrated distillation column. Based on qualitative knowledge the process interactions are illustrated using a \\{DYnamic\\} Quantity Interaction Diagram (DYQUID). From qualitative considerations a multiloop SISO control strategy, which concurs with intuitive engineering knowledge, is suggested. A linear state space model obtained from a non-linear simulation model is used to quantitatively analyse the control structuring problem. SVD analysis shows, that a multiloop control strategy is justified, and RGA analysis suggests the same loop structure as inferred qualitatively. Finally the overall control structure for the energy integrated distillation column is discussed in relation to experimental results.

Jens Karlsmose; Arne Koggersbøl; Niels Jensen; Sten Bay Jørgensen

1994-01-01T23:59:59.000Z

37

CR mammography: Design and implementation of a quality control program  

SciTech Connect (OSTI)

Despite the recent acquisition of significant quantities of computed radiography CR equipment for mammography, Mexican regulations do not specify the performance requirements for digital systems such as those of CR type. The design of a quality control program QCP specific for CR mammography systems was thus considered relevant. International protocols were taken as reference to define tests, procedures and acceptance criteria. The designed QCP was applied in three CR mammography facilities. Important deficiencies in spatial resolution, noise, image receptor homogeneity, artifacts and breast thickness compensation were detected.

Moreno-Ramirez, A.; Brandan, M. E.; Villasenor-Navarro, Y.; Galvan, H. A.; Ruiz-Trejo, C. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, DF 04510 (Mexico); Departamento de Radiodiagnostico, Instituto Nacional de Cancerologia, DF 14080 (Mexico); Instituto de Fisica, Universidad Nacional Autonoma de Mexico, DF 04510 (Mexico)

2012-10-23T23:59:59.000Z

38

How intense quality control improves hydraulic fracturing  

SciTech Connect (OSTI)

Not unlike the subject of Forced Closure, Intense Quality Control is probably misnamed. What actually is discussed in this article is pilot testing of the fracturing fluids actually pumped at in-situ conditions of temperature and shear. Presented here is development of the need for onsite testing, equipment used, shear and viscosity curves from several jobs showing what went wrong that would otherwise not have been known, and a discussion of borate gel fluids.

Ely, J.W. [Ely and Associates, Inc., Houston, TX (United States)

1996-11-01T23:59:59.000Z

39

Control of hazardous energy sources (lockout/tagout procedures)  

SciTech Connect (OSTI)

The Occupational Safety and Health Administration (OSHA) Standard 29 CFR 1910.147 addresses practices and procedures that are necessary to disable machinery or equipment and to prevent the release of potentially hazardous energy during maintenance operations. The standard contains definitive criteria for establishing an effective program for locking out or tagging out energy isolating devices. The standard contains major training requirements for those authorized to use the energy isolating devices and those that are affected by their use. Periodic inspections are required at least annually to ensure that the energy control procedures continue to be implemented properly.

Seidel, K.G.

1991-01-01T23:59:59.000Z

40

Quantitative Quality Management through Defect Prediction and Statistical Process Control  

E-Print Network [OSTI]

Quantitative Quality Management through Defect Prediction and Statistical Process Control Pankaj: To produce high quality software, the final software should have as few defects as possible. The task of quality management in a software project is to plan suitable quality control activities, and properly

Jalote, Pankaj

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Quality Control Inspector (QCI) Pre-Exam Quiz | Department of...  

Office of Environmental Management (EM)

Quality Control Inspector (QCI) Pre-Exam Quiz Quality Control Inspector (QCI) Pre-Exam Quiz This quiz is not representative of, nor related to the content of the actual QCI exam....

42

Regional Water Quality Control Boards | Open Energy Information  

Open Energy Info (EERE)

search OpenEI Reference LibraryAdd to library Legal Document- OtherOther: Regional Water Quality Control BoardsLegal Abstract California Regional Water Quality Control Boards,...

43

Colorado Water Quality Control Act | Open Energy Information  

Open Energy Info (EERE)

search OpenEI Reference LibraryAdd to library Legal Document- StatuteStatute: Colorado Water Quality Control ActLegal Abstract Statute setting forth laws for water quality control...

44

Preparing for the Quality Control Inspector Certification Exam...  

Broader source: Energy.gov (indexed) [DOE]

Department of Commerce, identifies how individuals can better prepare for the Home Energy Professional Quality Control Inspector Certification Exam. preparingfortheqci...

45

Quality Assurance/Quality Control (QA/QC) Summary for the California Rivers and Streams Study  

E-Print Network [OSTI]

APPENDIX 1 Quality Assurance/Quality Control (QA/QC) Summary for the California Rivers and Streams Ambient Monitoring Program (SWAMP) Quality Assurance Program Plan (QAPrP) are outlined in the Rivers QAPP may arise so that corrective actions can be implemented. Quality control samples prepared and analyzed

46

Hawaii Office of Environmental Quality Control Webpage | Open...  

Open Energy Info (EERE)

Control Webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Hawaii Office of Environmental Quality Control Webpage Author State of Hawaii...

47

NREL Job Task Analysis: Quality Control Inspector | Department...  

Broader source: Energy.gov (indexed) [DOE]

Control Inspector More Documents & Publications trainingselfassessment.xlsx Preparing for the Quality Control Inspector Certification Exam NREL Job Task Analysis: Energy Auditor...

48

A QUALITY CONTROL FRAMEWORK FOR BUS SCHEDULE RELIABILITY  

E-Print Network [OSTI]

A QUALITY CONTROL FRAMEWORK FOR BUS SCHEDULE RELIABILITY JIE LIN*, University of Illinois Institute A QUALITY CONTROL FRAMEWORK FOR BUS SCHEDULE RELIABILITY Abstract This paper develops and demonstrates a quality control framework for bus schedule reliability. Automatic Vehicle Location (AVL) devices

Illinois at Chicago, University of

49

Software Quality Assurance Control of Existing Systems  

Broader source: Energy.gov (indexed) [DOE]

2.01.00 - 2002 2.01.00 - 2002 Software Quality Assurance Control of Existing Systems September 2002 United States Department of Energy Albuquerque Operations Office Abstract Existing software systems often represent significant investments and play important roles in the every day businesses of organizations. Many of these systems are experiencing support problems. To meet current and future operational needs, organizations need to plan how best to address these support issues. Some of the issues to consider are presented in this document with references to related standards for further detailed examination. Two tutorials, one based on software maintenance and another detailing a baseline recovery strategy are included. SQA Control of Existing Systems SQAS22.01.00-2002

50

Procedures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Procedures A NSSAB outreach display is available for community events The Nevada Site Specific Advisory Board (NSSAB) abides by a variety of federal and self-imposed procedures....

51

Georgia Water Quality Control Act (Georgia) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Georgia Water Quality Control Act (Georgia) Georgia Water Quality Control Act (Georgia) Georgia Water Quality Control Act (Georgia) < Back Eligibility Agricultural Commercial Construction Developer Fuel Distributor Industrial Installer/Contractor Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Systems Integrator Transportation Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Environmental Regulations Siting and Permitting Provider Georgia Department of Natural Resources The Georgia Water Quality Control Act (WQCA) is a set of environmental regulations and permitting requirements that comply with the federal Clean Water Act. The Georgia Water Quality Control Act is enforced by the Georgia

52

Georgia Air Quality Control Act (Georgia) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Quality Control Act (Georgia) Air Quality Control Act (Georgia) Georgia Air Quality Control Act (Georgia) < Back Eligibility Agricultural Commercial Construction Developer Fuel Distributor Industrial Installer/Contractor Investor-Owned Utility Municipal/Public Utility Retail Supplier Rural Electric Cooperative Systems Integrator Transportation Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Climate Policies Environmental Regulations Provider Georgia Department of Natural Resources The Georgia Air Quality Control Act (AQCA) is a set of environmental regulations, permitting requirements, and air quality standards that control the amount of pollutants emitted and who emits them. The AQCA

53

P\\procedure\\FP#36 TITLE: GREEN BUILDING POLICY PROMOTING ENVIRONMENTAL QUALITY AND  

E-Print Network [OSTI]

P\\procedure\\FP#36 TITLE: GREEN BUILDING POLICY PROMOTING ENVIRONMENTAL QUALITY AND RESOURCE the U.S. Green Building Council's LEED Silver standard or equivalent. This policy will be limited% of building replacement value". RESPONSIBILITY: ACTION FACILITIES PLANNING DIRECTOR Ensure that the green

Fernandez, Eduardo

54

The mass production and quality control of RPCs for the Daya Bay Experiment  

SciTech Connect (OSTI)

Resistive plate chambers will be used in the Daya Bay reactor neutrino experiment to help veto backgrounds created by cosmic-ray muons. The mass production of RPCs began in 2008 and by the end of 2009, 1600 RPCs (3500 m{sup 2}) had been produced and tested. This paper describes the production and quality control procedures, and quality assurance using cosmic-ray testing.

Hackenburg R.

2011-03-30T23:59:59.000Z

55

Air Quality Rules (North Carolina)  

Broader source: Energy.gov [DOE]

This is a comprehensive air quality rule for North Carolina that includes ambient air quality standards, emission control standards, monitoring and reporting requirements, and permitting procedures...

56

ARM: Surface Radiation Measurement Quality Control testing, including climatologically configurable limits  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Surface Radiation Measurement Quality Control testing, including climatologically configurable limits

Hodges, Gary; Stoffel, Tom; Kutchenreiter, Mark; Kay, Bev; Habte, Aron; Ritsche, Michael; Morris, Victor; Anderberg, Mary

57

Title 18 Alaska Administrative Code Chapter 50 Air Quality Control...  

Open Energy Info (EERE)

Document- RegulationRegulation: Title 18 Alaska Administrative Code Chapter 50 Air Quality ControlLegal Published NA Year Signed or Took Effect 2004 Legal Citation Alaska...

58

Quality Control Inspector (QCI) Pre-Home Energy Professional...  

Energy Savers [EERE]

Energy Professional Certification Exam Quiz Quality Control Inspector (QCI) Pre-Home Energy Professional Certification Exam Quiz This quiz is not representative of, nor...

59

California State Water Resources Control Board 401 Water Quality...  

Open Energy Info (EERE)

navigation, search OpenEI Reference LibraryAdd to library Web Site: California State Water Resources Control Board 401 Water Quality Certification Website Abstract This website...

60

Analyst Tools and Quality Control Software for the ARM Data System  

SciTech Connect (OSTI)

ATK Mission Research develops analyst tools and automated quality control software in order to assist the Atmospheric Radiation Measurement (ARM) Data Quality Office with their data inspection tasks. We have developed a web-based data analysis and visualization tool, called NCVweb, that allows for easy viewing of ARM NetCDF files. NCVweb, along with our library of sharable Interactive Data Language procedures and functions, allows even novice ARM researchers to be productive with ARM data with only minimal effort. We also contribute to the ARM Data Quality Office by analyzing ARM data streams, developing new quality control metrics, new diagnostic plots, and integrating this information into DQ HandS - the Data Quality Health and Status web-based explorer. We have developed several ways to detect outliers in ARM data streams and have written software to run in an automated fashion to flag these outliers.

Moore, S.T.

2004-12-14T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Software Quality Assurance Control of Existing Systems | Department of  

Broader source: Energy.gov (indexed) [DOE]

Software Quality Assurance Control of Existing Systems Software Quality Assurance Control of Existing Systems Software Quality Assurance Control of Existing Systems Existing software systems often represent significant investments and play important roles in the every day businesses of organizations. To meet current and future operational needs, organizations need to plan how best to address these support issues. Some of the issues to consider are presented in this document with references to related standards for further detailed examination. Two tutorials, one based on software maintenance and another detailing a baseline recovery strategy are included Software Quality Assurance Control of Existing Systems More Documents & Publications Software Quality Assurance Control of Existing Systems Software Quality: A Guide to Responsibilities and Resources, SQAS

62

Should Title 24 Ventilation Requirements Be Amended to include an Indoor Air Quality Procedure?  

SciTech Connect (OSTI)

Minimum outdoor air ventilation rates (VRs) for buildings are specified in standards, including California?s Title 24 standards. The ASHRAE ventilation standard includes two options for mechanically-ventilated buildings ? a prescriptive ventilation rate procedure (VRP) that specifies minimum VRs that vary among occupancy classes, and a performance-based indoor air quality procedure (IAQP) that may result in lower VRs than the VRP, with associated energy savings, if IAQ meeting specified criteria can be demonstrated. The California Energy Commission has been considering the addition of an IAQP to the Title 24 standards. This paper, based on a review of prior data and new analyses of the IAQP, evaluates four future options for Title 24: no IAQP; adding an alternate VRP, adding an equivalent indoor air quality procedure (EIAQP), and adding an improved ASHRAE-like IAQP. Criteria were established for selecting among options, and feedback was obtained in a workshop of stakeholders. Based on this review, the addition of an alternate VRP is recommended. This procedure would allow lower minimum VRs if a specified set of actions were taken to maintain acceptable IAQ. An alternate VRP could also be a valuable supplement to ASHRAE?s ventilation standard.

Dutton, Spencer M.; Mendell, Mark J.; Chan, Wanyu R.

2013-05-13T23:59:59.000Z

63

Quality and Energy Control of Industrial Biscuit Baking  

Science Journals Connector (OSTI)

At present, industrial biscuit ovens are controlled by measuring the temperature in each oven section and keeping these temperatures at a predetermined value. A control system directly related to the quality of t...

Ubo de Vries; Paul Verlaan; Maas van der Vliert

1993-01-01T23:59:59.000Z

64

113 air quality control station [n  

Science Journals Connector (OSTI)

envir. (Facility for measurement of air pollution; ? air quality network/system );s estación [f] de medición de la calidad del aire (? red de ev...

2010-01-01T23:59:59.000Z

65

Online quality control methods for steam-gas reformers  

Science Journals Connector (OSTI)

This paper presents a classification of online quality control (QC) methods from the view of process control. The QC can be applied on the control loops from each of its three sides: the input (manipulative variable) side, the output (controlled variable) side and from the disturbance side. It was found that online QC can be direct or indirect, depending on the measures taken for quality. This classification can lead to interesting and new options for the control variables that otherwise would have been obscure. Once the proper control variable is selected (in terms of adequate representation of quality) it can be used for control systems analysis and design. Process application is presented for an industrial Steam Gas Reformer. The input is the fuel gas quality for which various options were presented. A correlation was obtained to relate heat input to simple measurements. The output hydrogen quality control options were discussed. Coil outlet temperature is adequate for a crude estimate of conversion, provided that S/C ratio is controlled. S/C ratio correlation was obtained to enable its estimation and control from simple measurements. A precise quality control of hydrogen can be achieved provided that COT is also controlled to protect reformer catalyst. An improved strategy can be implemented where both COT and conversion are controlled in a multivariable sense. This strategy is economically attractive, since it allows continuous manipulation of S/C ratio to the minimum required for COT control. Savings in fuel gas can be achieved accordingly. The feasibility of multivariable control was established via interaction analysis.

I.M. Alatiqi

1990-01-01T23:59:59.000Z

66

Software Quality Assurance Control of Existing Systems | Department of  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Assurance Control of Existing Systems Assurance Control of Existing Systems Software Quality Assurance Control of Existing Systems Existing software systems often represent significant investments and play important roles in the every day businesses of organizations. To meet current and future operational needs, organizations need to plan how best to address these support issues. Some of the issues to consider are presented in this document with references to related standards for further detailed examination. Two tutorials, one based on software maintenance and another detailing a baseline recovery strategy are included Software Quality Assurance Control of Existing Systems More Documents & Publications Software Quality Assurance Control of Existing Systems Software Quality: A Guide to Responsibilities and Resources, SQAS

67

EVALUATION OF THE INDOOR AIR QUALITY PROCEDURE FOR USE IN RETAIL BUILDINGS  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Evaluation of the Indoor Air Quality Evaluation of the Indoor Air Quality Procedure for Use in Retail Buildings Spencer M. Dutton, Wanyu R. Chan, Mark J. Mendell, Marcella Barrios, Srinandini Parthasarathy, Meera Sidheswaran, Douglas P. Sullivan, Katerina Eliseeva, William J. Fisk Environmental Energy Technologies Division Indoor Environment Group Lawrence Berkeley National Laboratory Berkeley, CA 94720 February 1, 2013 The research reported here was supported by the California Energy Commission Public Interest Energy Research Program, Energy-Related Environmental Research Program, award number 500-09-049.The study was additionally supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Building Technologies Program of the U.S. Department of Energy under contract DE-AC02-05CH11231.

68

Water Quality Control Act (Tennessee) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Water Quality Control Act (Tennessee) Water Quality Control Act (Tennessee) < Back Eligibility Agricultural Commercial Construction Developer Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Municipal/Public Utility Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Tennessee Program Type Environmental Regulations Siting and Permitting Provider Tennessee Department Of Environment and Conservation The Water Quality Control Act (WQCA) establishes the water pollution

69

Major: Ecological Systems Design, Air Quality Control and Waste Management  

E-Print Network [OSTI]

mechanics (Wang), 3 CP Air quality and health impact (Schleibinger, Wang, Wick), 3 CP Air Pollution Modeling pollution issues and control technology · Hands-on knowledge of state-of-the-art air quality monitoring questions · Solve complex problems from a system-oriented perspective · Understanding air pollution sources

Giger, Christine

70

Protein quality control in the mammalian endoplasmic reticulum  

E-Print Network [OSTI]

Quality control is an important part of protein biogenesis. Aberrant proteins must be destroyed before they aggregate and cause deleterious effects. Failure to do so can result in cell death or malfunction and, ultimately, ...

Klemm, Elizabeth J. (Elizabeth Joanna)

2011-01-01T23:59:59.000Z

71

EERE QC Workshop: Overview of Quality Control Techniques  

Broader source: Energy.gov [DOE]

Overview of quality control techniques by Michael Ulsh, National Renewable Energy Laboratory, at the EERE QC Workshop held December 9-10, 2013, at the National Renewable Energy Laboratory in Golden, Colorado.

72

Radiation safety and quality control in the cyclotron laboratory  

Science Journals Connector (OSTI)

......and Technical Papers Radiation safety and quality control...Forks, ND 58203, USA Radiation safety was determined to...to save SCADA node software and avoid run failure...prove compliance with radiation safety standards, and minimise......

Sushil Sharma; Gregory Krause; Manuchair Ebadi

2006-07-01T23:59:59.000Z

73

Preparing for the Quality Control Inspector Certification Exam  

Broader source: Energy.gov [DOE]

This presentation, prepared by the Building Performance Center and the Washington Department of Commerce, identifies how individuals can better prepare for the Home Energy Professional Quality Control Inspector Certification Exam.

74

Data Quality Control Based on Self-Consistency  

Science Journals Connector (OSTI)

Conducting meteorological measurements, one is always confronted with a wide variety of different types of errors and with the decision of how to correct data for further use, if necessary. The selection of an adequate quality control (QC) ...

Reinhold Steinacker; Dieter Mayer; Andrea Steiner

2011-12-01T23:59:59.000Z

75

School of Health and Social Work Rules of Procedure and Proceedings with respect to a Student's Complaint regarding the Quality  

E-Print Network [OSTI]

/or the Associate Dean of School, Academic Quality Assurance (Practice Enhancement). 1.4 Students who are employedSchool of Health and Social Work Rules of Procedure and Proceedings with respect to a Student's Complaint regarding the Quality of the Learning Experience on Practice and Work Placements Version : 01

Kaye, Paul

76

Water Quality (Louisiana)  

Broader source: Energy.gov [DOE]

These regulations establish requirements and procedures for permitting, enforcement, monitoring, and surveillance, and spill control activities of the Department of Environmental Quality. Without...

77

Magnetically Controlled Reactor Shrinks Power Quality Costs and Power  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Magnetically Controlled Reactor Shrinks Power Quality Costs and Power Magnetically Controlled Reactor Shrinks Power Quality Costs and Power Losses Speaker(s): Mark D. Galperin Date: December 18, 2000 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Diana Morris In a new, magnetically controlled reactor (MCR), in which DC pulsing through a special winding controls inductive susceptance, high saturation of the magnetic circuit steel with optimal magnetic and electrical circuit parameters ensures less than 2-3% main harmonic distortion even without special filters. Transformer-like construction ensures reliable operation. MCR's increase power quality through automatic voltage regulation, reduced fluctuation, and smoothing of reactive power surges at 1/2 the cost of thyristor-controlled reactors (TCR's). Damping of voltage-oscillation

78

Hawaii Department of Health Office of Environmental Quality Control | Open  

Open Energy Info (EERE)

Office of Environmental Quality Control Office of Environmental Quality Control Jump to: navigation, search Name Hawaii Department of Health Office of Environmental Quality Control Address 235 S. Beretania Suite 702 Place Honolulu, Hawaii Zip 96813 Website http://hawaii.gov/health/envir Coordinates 21.3094485°, -157.8578603° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":21.3094485,"lon":-157.8578603,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

79

A Toolkit for Building Energy Consumption Data Quality Assurance/Quality Control  

E-Print Network [OSTI]

Conference Enhanced Building Operations, New York City, October 18-20, 2011 ICEBO 2011 ? New York JCB/ESL Outline ? Motivation ? Building Energy Data Quality Assurance/Quality Control (QA/QC) Project ? Tool Development ? Inputs... Occurred ESL-IC-11-10-30 Proceedings of the Eleventh International Conference Enhanced Building Operations, New York City, October 18-20, 2011 ICEBO 2011 ? New York JCB/ESL Building Energy Data QA/QC Project ? 150 Campus...

Baltazar, J.C.

2011-01-01T23:59:59.000Z

80

Tank Monitoring and Control System (TMACS) Acceptance Test Procedure  

SciTech Connect (OSTI)

This document is used to validate Revision 13.0 of the Tank Monitor and Control System (TMACS) and verify it functions as intended by design.

BARNES, D.A.

2000-12-14T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Chapter 3 -Energy Control Program The purpose of the OSU energy control program is to clearly define procedures for the  

E-Print Network [OSTI]

, chemical, gravitational, and thermal need to be considered. 1. Lockout/Tagout Procedures The primary method of control of hazardous energy is utilization of lockout/tagout procedures. Supervisors are responsible for identifying equipment having the characteristics defined above and for providing instruction in the lockout

82

Microsoft Word - Appendix E - Erosion Control M&M Inspection Procedure.docx  

Office of Legacy Management (LM)

Rocky Flats, Colorado, Site Rocky Flats, Colorado, Site Erosion Control Monitoring and Maintenance Inspection Procedure This page intentionally left blank LMS/RFS/S04532 Rocky Flats, Colorado, Site Erosion Control Monitoring and Maintenance Inspection Procedure April 2012 This page intentionally left blank U.S. Department of Energy Rocky Flats Erosion Control Monitoring and Maintenance Inspection Procedure April 2012 Doc. No. S04532 Page 1 1.0 Introduction The Erosion Control Plan for Rocky Flats Property Central Operable Unit (DOE 2007) addresses the best management practices (BMPs) to adequately control storm water runoff of soils that could ultimately discharge into surface water. Under the Erosion Control Plan, inspections of the implemented BMP erosion control measures must be conducted on a regular

83

GenePRIMP: A software quality control tool  

ScienceCinema (OSTI)

Amrita Pati of the DOE Joint Genome Institute's Genome Biology group describes the software tool GenePRIMP and how it fits into the quality control pipeline for microbial genomics. Further details regarding GenePRIMP appear in a paper published online May 2, 2010 in Nature Methods.

Amrita Pati

2010-09-01T23:59:59.000Z

84

Transformer Thermal Modeling: Improving Reliability Using Data Quality Control  

E-Print Network [OSTI]

1 Transformer Thermal Modeling: Improving Reliability Using Data Quality Control Daniel J. Tylavsky--Eventually all large transformers will be dynamically loaded using models updated regularly from field measured data. Models obtained from measured data give more accurate results than models based on transformer

85

Quality assurance with the ISFH-Input/Output-Procedure 6-year-experience with 14 solar thermal systems  

E-Print Network [OSTI]

sensors into a solar system with buffer storage tank and direct discharging. Figure 1 shows the sensorsQuality assurance with the ISFH-Input/Output-Procedure 6-year-experience with 14 solar thermal of standard solar thermal systems usually don't recognise failures affecting the solar yield, because

86

Minimizing damage to a propped fracture by correct selection of proppant and controlled flowback procedures  

E-Print Network [OSTI]

MINIMIZING DAMAGE TO A PROPPED FRACTURE BY CORRECT SELECTION OF PROPPANT AND CONTROLLED FLOWBACK PROCEDURES A Thesis by BRADLEY MASON ROBINSON Submitted to the Graduate College of Texas ASM University in partial fulfillment... of the requirements for the degree of MASTER OF SCIENCE May 1986 Major Subject: Petroleum Engineering MINIMIZING DAMAGE TO A PROPPED FRACTURE BY CORRECT SELECTION OF PROPPANT AND CONTROLLED FLOWBACK PROCEDURES A Thesis by BRADLEY MASON ROBINSON Approved...

Robinson, Bradley Mason

1986-01-01T23:59:59.000Z

87

PROCEDURE COVER SHEET Princeton Plasma Physics Laboratory  

E-Print Network [OSTI]

Quality Assurance/Quality Control AC Power Maintenance and Operations Division Energy Conversion Systems Only" training for Administrative, Alarm Response, and Emergency Operations procedures must Engineering Environmental Restoration & Waste Management Division Water Systems Neutral Beam (Heating Systems

Princeton Plasma Physics Laboratory

88

Model Quality Control Matrix Tools for Defining Commissioning Process  

E-Print Network [OSTI]

by overriding, deleting and/or adding. ?It is used to define most of the necessary procedures required for commissioning authority as well as commissioning-related parties during the building production stage and operation stage. ?MQC tool is a control tool...Cell ContentsS p ecificationS p ecification2URLMAILOther Files??????????????1???2?????????????????????????????????????????????http://www.hptcj.or.jp/chikun etu/tools/index.html ??????????????????????????????????? ?? ?????????????????????????????????????????http://www.hptcj.or...

Nakahara, N.; Onojima, H.; Kamitani, K.

2004-01-01T23:59:59.000Z

89

Tank Monitoring and Control System (TMACS) Acceptance Test Procedure  

SciTech Connect (OSTI)

The purpose of this document is to describe tests performed to validate Revision 12.0 of the TMACS Monitor and Control System (TMACS) and verify that the software functions as intended by design. This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be communicating to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab.

BARNES, D.A.

2000-06-01T23:59:59.000Z

90

E-Print Network 3.0 - analytical quality control Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

this trial and error process without sacrificing quality. Process control... the design process, and result in better quality products. A neural model can also supplement...

91

ARS Title 49-200 Water Quality Control | Open Energy Information  

Open Energy Info (EERE)

Water Quality Control Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- StatuteStatute: ARS Title 49-200 Water Quality ControlLegal Abstract...

92

A quality control framework for bus schedule reliability Jie Lin a,*, Peng Wang b  

E-Print Network [OSTI]

A quality control framework for bus schedule reliability Jie Lin a,*, Peng Wang b , Darold T and demonstrates a quality control framework for bus schedule reliability. Automatic vehicle loca- tion (AVL demonstrating that it can provide quick and accurate quality control. Published by Elsevier Ltd. Keywords

Illinois at Chicago, University of

93

An expert system advisor for well log quality control  

E-Print Network [OSTI]

Taxonomy for the Sonic Iog C2 Taxonomy for the Gamma Ray lcg C3 Taxonomy for the Dual Induction Iog . Dl Gamma Ray Inf~ Trees . D2 Gamma Ray Inference Trees (Cont. ) D 3 Gamma Ray Inference Trees (Cont. ) D4 Dual Induction Inference Trees D5 Dual... FOR WELL IOG QUALITY CONTROL 17 OB3ECZIVFK SYSTEM DEVEIOFKENT 17 19 SUMMARY DISCUSSION SUGGESTIONS FOR FVHBK RESEARCH 31 33 41 APPENDIX A ? GIOSSARY OF ~ SYSTEM TERMINOIOGY . . 44 APPENDIX B ? AN ~ CONSULTATION SESSION WITH THE SONIC IOG...

Warnken, Dean Kennedy

2012-06-07T23:59:59.000Z

94

Economic Plantwide Control Over a Wide Throughput Range: A Systematic Design Procedure  

E-Print Network [OSTI]

systems for safe, stable, and economic process operation of complex chemical processes with material for integrated chemical processes.3 In their procedure, economic concerns are addressed indirectly in the form of requiring "tight" control of expected economic variables such as product impurity and process yield

Skogestad, Sigurd

95

Evaluation of the Indoor Air Quality Procedure for Use in Retail Buildings  

E-Print Network [OSTI]

indoor pollutant source control measures and air cleaningof indoor pollutant source control measures or gas phase aircontrol indoor pollutants, by allowing lower energy costs from reduced outdoor air

Dutton, Spencer M.

2014-01-01T23:59:59.000Z

96

New process modeling [sic], design, and control strategies for energy efficiency, high product quality, and improved productivity in the process industries. Final project report  

SciTech Connect (OSTI)

This project was concerned with the development of process design and control strategies for improving energy efficiency, product quality, and productivity in the process industries. In particular, (i) the resilient design and control of chemical reactors, and (ii) the operation of complex processing systems, was investigated. Specific topics studied included new process modeling procedures, nonlinear controller designs, and control strategies for multiunit integrated processes. Both fundamental and immediately applicable results were obtained. The new design and operation results from this project were incorporated into computer-aided design software and disseminated to industry. The principles and design procedures have found their way into industrial practice.

Ray, W. Harmon

2002-06-05T23:59:59.000Z

97

Cumulative sum quality control for calibrated breast density measurements  

SciTech Connect (OSTI)

Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

Heine, John J.; Cao Ke; Beam, Craig [Cancer Prevention and Control Division, Moffitt Cancer Center, 12902 Magnolia Drive, Tampa, Florida 33612 (United States); Division of Epidemiology and Biostatistics, School of Public Health, University of Illinois at Chicago, 1603 W. Taylor St., Chicago, Illinois 60612 (United States)

2009-12-15T23:59:59.000Z

98

Research and Application of Intelligent Quality Control System Based on FMEA Repository  

Science Journals Connector (OSTI)

Although statistical process control (SPC) provides statistical techniques and graphical displays control charts to enable the quality of process to be monitored and special causes of process variability to be eliminated, this technology has been not ... Keywords: Manufacturing Process, Intelligent Quality Control, Statistical Process Control, FMEA Repository, Process Continuing Improvement

Xiuxu Zhao; Yu-bao Ma; Rui Cai; Xiao-li Bai; Lin-yan Ning

2009-07-01T23:59:59.000Z

99

A comparative study on different assessment procedures applied to loudspeaker sound quality  

E-Print Network [OSTI]

the listener's expectations towards this item. Moreover, for the specific case of sound reproduction devices of a sound re- production device such as a loudspeaker is its sound quality. The perception of this subjective character is linked to numerous parameters (stimulus type, listening environment...) that must

Paris-Sud XI, Université de

100

Technical background document for the Great Lakes water quality guidance implementation procedures compliance cost study  

SciTech Connect (OSTI)

The document presents the detailed results of the evaluations performed to estimate the compliance costs related to the proposed Great Lakes Water Quality Guidance. Specifically, the document provides the results of the individual evaluations performed on the 59 sample facilities selected to represent the direct discharges to the Great Lakes System.

Parikh, P.; Fenner, K.; Podar, M.; Snyder, B.

1993-04-16T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Comparison of Conventional and Fuzzy Control of Indoor Air Quality in Buildings  

Science Journals Connector (OSTI)

This article compares various techniques for the control of indoor air quality in a naturally ventilated building: ON-OFF, proportional-integral-derivative PID, proportional-integral with deadband PIdb, and fuzzy control. The control system for the fuzzy ...

A. I. Dounis; M. Bruant; M. Santamouris; G. Guarracino; P. Michel

1996-03-01T23:59:59.000Z

102

24.01.01.M4.01 Bloodborne Pathogens Exposure Control Page 1 of 4 STANDARD ADMINISTRATIVE PROCEDURE  

E-Print Network [OSTI]

, 2008 Revised May 8, 2013 Next scheduled review: May 8, 2016 Standard Administrative Procedure Statement Standard, Texas A&M University has established a University Bloodborne Pathogens Exposure Control Plan24.01.01.M4.01 Bloodborne Pathogens Exposure Control Page 1 of 4 STANDARD ADMINISTRATIVE PROCEDURE

103

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California: Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure  

E-Print Network [OSTI]

5 III. Current ASHRAE 62.1 Indoor Air Quality Procedure (satisfied with indoor air quality in office buildings inthe U.S. in taking indoor air quality seriously, in the same

Mendell, Mark

2014-01-01T23:59:59.000Z

104

Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont)  

Broader source: Energy.gov [DOE]

The ambient air quality standards are based on the national ambient air quality standards. The Vermont standards are classified as primary and secondary standards and judged adequate to protect...

105

An overview of the comprehensive proton therapy machine quality assurance procedures implemented at The University of Texas M. D. Anderson Cancer Center Proton Therapy Center-Houston  

SciTech Connect (OSTI)

The number of proton and carbon ion therapy centers is increasing; however, since the publication of the International Commission on Radiation Units and Measurements report, there has been no dedicated report dealing with proton therapy quality assurance. The purpose of this article is to describe the quality assurance procedures performed on the passively scattered proton therapy beams at The University of Texas M. D. Anderson Cancer Center Proton Therapy Center in Houston. The majorities of these procedures are either adopted from procedures outlined in the American Association of Physicists in Medical Task Group (TG) 40 report or are a modified version of the TG 40 procedures. In addition, new procedures, which were designed specifically to be applicable to the synchrotron at the author's center, have been implemented. The authors' procedures were developed and customized to ensure patient safety and accurate operation of synchrotron to within explicit limits. This article describes these procedures and can be used by others as a guideline for developing QA procedures based on particle accelerator specific parameters and local regulations pertinent to any new facility.

Arjomandy, Bijan; Sahoo, Narayan; Zhu, X. Ronald; Zullo, John R.; Wu, Richard Y.; Zhu Mingping; Ding Xiaoning; Martin, Craig; Ciangaru, George; Gillin, Michael T. [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1840 Old Spanish Trail, Houston, Texas 77025 (United States)

2009-06-15T23:59:59.000Z

106

REVIEW Of COMPUTERIZED PROCEDURE GUIDELINES FOR NUCLEAR POWER PLANT CONTROL ROOMS  

SciTech Connect (OSTI)

Computerized procedures (CPs) are recognized as an emerging alternative to paper-based procedures for supporting control room operators in nuclear power plants undergoing life extension and in the concept of operations for advanced reactor designs. CPs potentially reduce operator workload, yield increases in efficiency, and provide for greater resilience. Yet, CPs may also adversely impact human and plant performance if not designed and implemented properly. Therefore, it is important to ensure that existing guidance is sufficient to provide for proper implementation and monitoring of CPs. In this paper, human performance issues were identified based on a review of the behavioral science literature, research on computerized procedures in nuclear and other industries, and a review of industry experience with CPs. The review of human performance issues led to the identification of a number of technical gaps in available guidance sources. To address some of the gaps, we developed 13 supplemental guidelines to support design and safety. This paper presents these guidelines and the case for further research.

David I Gertman; Katya Le Blanc; Ronald L Boring

2011-09-01T23:59:59.000Z

107

Matlab Toolbox to Perform Secondary Quality Control (2nd on Hydrographic Data  

E-Print Network [OSTI]

Matlab Toolbox to Perform Secondary Quality Control (2nd QC) on Hydrographic Data Toste Tanhua, Leibniz Institute for Marine Sciences, Kiel, Germany. This Matlab package will help you perform secondary cite as: Tanhua, T. 2010. Matlab Toolbox to Perform Secondary Quality Control (2nd QC) on Hydrographic

108

In and Out of the ER: Protein Folding, Quality Control, Degradation, and Related Human Diseases  

E-Print Network [OSTI]

In and Out of the ER: Protein Folding, Quality Control, Degradation, and Related Human Diseases 1377 C. Protein folding 1378 II. Protein Translocation, Folding, and Quality Control in the Endoplasmic Reticulum 1379 A. Protein targeting to the ER 1379 B. Chaperone-assisted protein folding in the ER 1379 C

Hebert, Daniel N.

109

Quality Assurance Specialist  

Broader source: Energy.gov [DOE]

Alternate Title(s):Quality Control Technician; Quality Assurance Inspector; Quality Assurance Representative

110

Exploring former interaction qualities for tomorrow's control room design  

E-Print Network [OSTI]

.g. in power plants or industrial production plants. One essential task in operating control rooms consists by virtual control elements that are operated through desktop computers. However this kind of interaction between power and reality as stated by Jacob et al. (2008): While digitization gave control rooms more

Reiterer, Harald

111

Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology  

SciTech Connect (OSTI)

Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 {+-} 2.3 (mean {+-} SD) and 2.6 {+-} 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data require confirmation with a broader incident-reporting database.

Ford, Eric C., E-mail: eford@uw.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland (United States); Terezakis, Stephanie; Souranis, Annette; Harris, Kendra [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland (United States)] [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland (United States); Gay, Hiram; Mutic, Sasa [Department of Radiation Oncology, Washington University, St. Louis, Missouri (United States)] [Department of Radiation Oncology, Washington University, St. Louis, Missouri (United States)

2012-11-01T23:59:59.000Z

112

Developing standard performance testing procedures for material control and accounting components at a site  

SciTech Connect (OSTI)

The condition of a nuclear material control and accountability system (MC&A) and its individual components, as with any system combining technical elements and documentation, may be characterized through an aggregate of values for the various parameters that determine the system's ability to perform. The MC&A system's status may be functioning effectively, marginally or not functioning based on a summary of the values of the individual parameters. This work included a review of the following subsystems, MC&A and Detecting Material Losses, and their respective elements for the material control and accountability system: (a) Elements of the MC&A Subsystem - Information subsystem (Accountancy/Inventory), Measurement subsystem, Nuclear Material Access subsystem, including tamper-indicating device (TID) program, and Automated Information-gathering subsystem; (b) Elements for Detecting Nuclear Material Loses Subsystem - Inventory Differences, Shipper/receiver Differences, Confirmatory Measurements and differences with accounting data, and TID or Seal Violations. In order to detect the absence or loss of nuclear material there must be appropriate interactions among the elements and their respective subsystems from the list above. Additionally this work includes a review of regulatory requirements for the MC&A system component characteristics and criteria that support the evaluation of the performance of the listed components. The listed components had performance testing algorithms and procedures developed that took into consideration the regulatory criteria. The developed MC&A performance-testing procedures were the basis for a Guide for MC&A Performance Testing at the material balance areas (MBAs) of State Scientific Center of the Russian Federation - Institute for Physics and Power Engineering (SSC RF-IPPE).

Scherer, Carolynn P [Los Alamos National Laboratory; Bushlya, Anatoly V [ROSATOM, RUSSIA; Efimenko, Vladimir F [IPPE, RUSSIA; Ilyanstev, Anatoly [IPPE, RUSSIA; Regoushevsky, Victor I [IPPE, RUSSIA

2010-01-01T23:59:59.000Z

113

Sampling and Statistical Quality Control with an Example from Industry  

E-Print Network [OSTI]

; percentage of defective units needs methods to monitor quality in a reliable way even if it cannot check. Even the seemingly uncomplicated task of counting the number of defective units in a large batch in Finland who have never owned a car, our population is equal to the population of Finland. Or if we wish

Pedicini, Marco

114

MARKIS: The Dutch marine database and its quality control system J. B. Wijngaard  

E-Print Network [OSTI]

2006 #12;1 Contents Introduction 3 History 4 To a relational database 5 MARKIS database 6 QualityMARKIS: The Dutch marine database and its quality control system J. B. Wijngaard De Bilt, February a long history of collecting and archiving marine data. In 1854 Dutch merchant ships started to transfer

Stoffelen, Ad

115

Managing the quality of a resource with stock and flow controls  

E-Print Network [OSTI]

stock. Thus, we try to prevent the deterioration of environmental quality and to keep our roads wellManaging the quality of a resource with stock and flow controls Nathaniel Keohane a, , Benjamin Van Roy b , Richard Zeckhauser c a Yale University, United States b Stanford University, United States c

Van Roy, Ben

116

E-Print Network 3.0 - air quality control Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Powered by Explorit Topic List Advanced Search Sample search results for: air quality control Page: << < 1 2 3 4 5 > >> 1 AQAST Short-Term Project PI: Richard McNider, University...

117

Quality Control in the Radiological Departments of the Florence General Hospital  

Science Journals Connector (OSTI)

......Quality Control in the Radiological Departments of the Florence General Hospital C. Gori G. Belli S. Calvagno L. Capaccioli A. Guasti G. Spano G. Zatelli At the Hospital of Careggi in Florence six radiological departments are currently active......

C. Gori; G. Belli; S. Calvagno; L. Capaccioli; A. Guasti; G. Spanò; G. Zatelli

1995-01-01T23:59:59.000Z

118

NMS 74-6-4 Duties and Powers of the Water Quality Control Commission...  

Open Energy Info (EERE)

NMS 74-6-4 Duties and Powers of the Water Quality Control Commission Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- StatuteStatute: NMS 74-6-4...

119

Improved Quality Control Processing of Peptide-centric LC-MS...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

statistically extreme LC-MS runs. Citation: Matzke MM, KM Waters, TO Metz, JM Jacobs, A Sims, R Baric, JG Pounds, and BJM Webb-Robertson.2011."Improved Quality Control Processing...

120

Princeton Plasma Physics Laboratory Procedure Title: Access to NSTX Experimental Areas  

E-Print Network [OSTI]

NSTX D-Site Caretaking Vacuum Computer Tritium Quality Assurance/Quality Control AC Power Maintenance of this procedure is to delineate the rules and requirements for access to the NSTX experimental areas

Princeton Plasma Physics Laboratory

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Online Weld Quality NDE & Control with IR Thermography  

Broader source: Energy.gov (indexed) [DOE]

noise * Ice Cubes - 0C. Large temperate differential (dT25C), but wet * Vortex Tube Cold Air Gun - dT15C, difficult to control air flow, less consistent * Hot...

122

Quality Management | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Quality Management Quality Management Quality Management The Office of Quality Management, within the Office of Health, Safety and Security develops policies and procedures to ensure the classification and control of information is effective and consistent. The Office of Quality Management also assists other Government agencies to meet the requirements contained in DOE-issued regulations concerning Restricted Data and Formerly Restricted Data. To meet these missions, the Office of Quality Management: Develops and revises DOE Regulations and Orders concerning Restricted Data, Formerly Restricted Data, Transclassified Foreign Nuclear Information, National Security Information, Unclassified Controlled Nuclear Information, and Official Use Only Responds to Mandatory Declassification Review Requests under

123

The Development of Test Procedures for controlling the Quality of the Manufacture of Engineered Compression Stockings.  

E-Print Network [OSTI]

??A new technology platform known as ‘Scan2Knit’ was invented in the William Lee innovation Centre of the University of Manchester to engineer and manufacture compression… (more)

Moghaddassian Shahidi, Arash

2010-01-01T23:59:59.000Z

124

Office of Quality Management  

Broader source: Energy.gov [DOE]

The Office of Quality Management develops and interprets Government-wide policies and procedures and conducts training to ensure the accurate identification of information and documents that must be classified or controlled under statute or Executive order to protect the national security and controlled unclassified Official Use Only information for the effective operation of the Government.

125

Ecotoxicity of sediments in stormwater quality control facilities  

SciTech Connect (OSTI)

The characteristics of accumulated sediments were investigated, with a focus on selected trace metals, in three stormwater management facilities and one natural site, all located in the Regional Municipality of Ottawa-Carleton, in Ontario, Canada. This study was conducted in response to concerns expressed by Environment Canada about possible ecosystem impacts by contaminants accumulated in these commonly applied, passive treatment systems. Also of interest were the effects of facility configuration, and operation and maintenance on particulate deposition patterns and resulting exposure risk. This was the first phase of a multidisciplinary study to quantify the risk of ecosystem effects in these systems, and results indicate that there are some significant potential risks present. In addition, results indicate that a simple comparison with provincial sediment quality guidelines may not be sufficient to alert facility owners and operators to these potential risks.

Anderson, B.C.; Loon, G. van; Watt, W.E.; Marsalek, J.

1999-07-01T23:59:59.000Z

126

aimer: This guideline is designed primarily as an educational resource for clinicians to help them provide quality medical care It should not be considered inclusive of all proper procedures and tests or exclusive of other procedures and tests that are re  

E-Print Network [OSTI]

provide quality medical care It should not be considered inclusive of all proper procedures and tests or exclusive of other procedures and tests that are reasonably directed to obtaining the same results the propriety of any specific procedure or test, the clinician should apply his or her own professional judgment

Levin, Judith G.

127

Real-Time Control of Diesel Combustion Quality  

SciTech Connect (OSTI)

Detroit Diesel Corporation (DDC) and ORNL established this CRADA to improve heavy-duty engine efficiency with reduced emissions at relatively extreme operating regimes such has high EGR, low-load, and cold-start, with an emphasis on the application of advanced control strategies. The approach used in this collaborative effort was to include the application of novel analysis and modeling techniques devel-oped from the application of nonlinear dynamics and chaos theory. More specifically, analytical tech-niques derived from these theories were to used to detect, characterize, and control the combustion insta-bilities that are responsible for poor combustion performance and corresponding high emissions. The foundation of this CRADA was established based on ORNL expertise on the fundamentals of ad-vanced combustion operation and experience with nonlinear dynamics and controls in combustion sys-tems. The initial plan was all data generation would be performed at DDC with an agreed upon experi-mental plan formed by both organizations. While numerous experiments were performed at DDC and the data was exchanged with ORNL researchers, the team decided to transfer an engine to ORNL to allow more flexibility and data generation opportunities. A prototype DDC Series 60 with a common rail fuel system was selected and installed at ORNL. DDC and ORNL maintained a strong collaboration throughout much of this project. Direct funding from DOE ended in 2004 and DDC continued to fund at a reduced amount through 2007. This CRADA has not been funded in more recent years but has been maintained active in anticipation of restored funding. This CRADA has led to additional collaborations between DDC and ORNL.

Wagner, R.M.; Sisken, K (Detroit Diesel Corp.)

2010-06-30T23:59:59.000Z

128

CEMS (continuous emission monitoring systems) pilot project: evaluation of opacity CEMS reliability and QA (quality assurance) procedures. Volume 1  

SciTech Connect (OSTI)

A study was conducted in Missouri to evaluate the reliability of opacity-monitoring data and to facilitate the development and evaluation of QA procedures for opacity CEMS's. The study included opacity CEMS's installed on six coal-fired electric utility generating units at four generating stations, each owned by a different company. The sources were representative of a wide range of monitoring applications and conditions, and were equipped with contemporary opacity monitoring instrumentation. For each station, monitor- and source-specific opacity CEMS QA procedures were developed and CEMS audits were conducted at the beginning of the study. Plant personnel implemented and revised the QA procedures and conducted a performance audit during a 6- to 8-month period. Performance audits were also conducted at the end of the study. The report presents evaluations both of opacity CEMS reliability (i.e., accuracy, precision, and availability) and of the QA procedures that were used in the study. In summary, appropriate and effective QA procedures can be developed and implemented for a variety of opacity monitoring equipment and applications without imposing an undue burden on the monitor operators. Such procedures are inherently source- and monitor-specific. Reliable opacity monitoring data are obtained when appropriate QA procedures are implemented.

Peeler, J.W.

1986-05-01T23:59:59.000Z

129

Improving waveform quality in direct power control of DFIG using fuzzy controller  

Science Journals Connector (OSTI)

This paper proposes a new direct power control (DPC) strategy of double-fed induction generator using fuzzy logic controller. The active and reactive power equations are expanded, and effects of voltage vecto...

H. Z. Boroujeni; M. F. Othman; A. H. Shirdel…

2014-11-01T23:59:59.000Z

130

Audit of the Savannah River Site's Quality Control Program for Groundwater Sampling, IG-0405  

Broader source: Energy.gov (indexed) [DOE]

0, 1997 0, 1997 MEMORANDUM FOR: THE SECRETARY FROM: John C. Layton Inspector General SUBJECT: INFORMATION: Report on "Audit of the Savannah River Site's Quality Control Program for Groundwater Sampling" BACKGROUND The Savannah River Site's groundwater remediation program was managed by the Department of Energy's (Department) management and operating contractor for the site, Westinghouse Savannah River Company (Westinghouse). One component of the remediation

131

Quality Control and Verification of Weather Radar Wind Profiles IWAN HOLLEMAN  

E-Print Network [OSTI]

- tions of the vertical velocity, which is a sum of the vertical wind velocity and the hydrometeor fall. 1986). Profiles of wind speed and direction, hydrometeor fall speed, and divergence have been obtainedQuality Control and Verification of Weather Radar Wind Profiles IWAN HOLLEMAN Royal Netherlands

Stoffelen, Ad

132

Scanning white light interferometry in quality control of single-point tape automated bonding  

Science Journals Connector (OSTI)

We report on applying a scanning white light interferometry (SWLI) for quality control of aluminum lead single-point tape automated bonding (spTAB). A spTAB process was used to connect Al leads on a thin polyimide flex to Al bond pads on a flexible Al-polyimide ... Keywords: Bonding, Interferometry

Ivan Vl. Kassamakov; Henri O. Seppänen; Markku J. Oinonen; Edward O. Híggström; J. Mathias Österberg; Juha P. Aaltonen; Heimo Saarikko; Zoran P. Radivojevic

2007-01-01T23:59:59.000Z

133

Documenting Visual Quality Controls on the Evaluation of Petroleum Reservoir-rocks through  

E-Print Network [OSTI]

) processes control the distribution of porosity and permeability within petroleum reservoir rocks section in a time unit. The values and distribution of porosity and permeability within reservoir rocks and prediction of the quality (porosity, permeability) of petroleum reservoirs during their exploration

Oliveira, Manuel M.

134

Diffusion-wave laser radiometric diagnostic quality-control technologies for materials NDE/NDT  

E-Print Network [OSTI]

Diffusion-wave laser radiometric diagnostic quality-control technologies for materials NDE/NDT A in two emerging NDE/NDT technologies. The solution of the ill-posed thermal- wave inverse problem has radiometric NDE metrology capable of measuring the primary photo- injected free carrier parameters

Mandelis, Andreas

135

Applying infrared thermography as a quality-control tool for the rapid  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Applying infrared thermography as a quality-control tool for the rapid Applying infrared thermography as a quality-control tool for the rapid detection of polymer-electrolyte-membrane-fuel-cell catalyst-layer-thickness variations Title Applying infrared thermography as a quality-control tool for the rapid detection of polymer-electrolyte-membrane-fuel-cell catalyst-layer-thickness variations Publication Type Journal Article Year of Publication 2012 Authors Aieta, Niccolo V., Prodip K. Das, Andrew Perdue, Guido Bender, Andrew M. Herring, Adam Z. Weber, and Michael J. Ulsh Journal Journal of Power Sources Volume 211 Pagination 4 - 11 Date Published 8/2012 ISSN 03787753 Keywords catalyst layer, corrosion, defects, fuel cell, infrared thermography, manufacturing, pemfc, quality control Abstract As fuel cells become more prominent, new manufacturing and production methods are needed to enable increased volumes with high quality. One necessary component of this industrial growth will be the accurate measurement of the variability of a wide range of material properties during the manufacturing process. In this study, a method to detect defects in fuel cell catalyst layers is investigated through experiment and mathematical simulation. The method uses infrared thermography and direct-current electronic-excitation methods to detect variations in platinum-containing catalyst-layer thickness with high spatial and temporal resolution. Data analysis, operating-condition impacts, and detection limits are explored, showing the measurement of defects on the millimeter length scale. Overall, the experimental and modeling results demonstrate great potential of this technique as a nondestructive method to measure defects that is amenable to use on roll-to-roll manufacturing lines.

136

Report of the Review of the Hanford Solid Waste Environmental Impact Statement regarding Data Quality Control and Management Issues  

Broader source: Energy.gov (indexed) [DOE]

Review of the Hanford Review of the Hanford Solid Waste Environmental Impact Statement (EIS) Data Quality, Control and Management Issues January 2006 Hanford Solid Waste Environment Impact Statement (EIS) Data Quality, Control and Management Issues Review Report ii Contents EXECUTIVE SUMMARY .................................................................................. IV 1.0 BACKGROUND ................................................................................................................ 1 2.0 REVIEW APPROACH....................................................................................................... 1 3.0 SUMMARY........................................................................................................................ 2 4.0 REVIEW RESULTS........................................................................................................... 4

137

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California: Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure  

E-Print Network [OSTI]

control should be the first priority instead of dilution of pollutants by ventilation or by cleaning the air.air quality, could better provide healthful indoor environments, and also reward designers and owners who control indoor pollutantsair quality, could better document healthful indoor environments, and also reward designers and owners who control indoor pollutants

Mendell, Mark

2014-01-01T23:59:59.000Z

138

AstroCloud, a Cyber-Infrastructure for Astronomy Research: Data Archiving and Quality Control  

E-Print Network [OSTI]

AstroCloud is a cyber-Infrastructure for Astronomy Research initiated by Chinese Virtual Observatory (China-VO) under funding support from NDRC (National Development and Reform commission) and CAS (Chinese Academy of Sciences){\\url{http://astrocloud.china-vo.org}}\\citep{O8-5_Cui_adassxxiv}. To archive the astronomical data in China, we present the implementation of the astronomical data archiving system (ADAS). Data archiving and quality control are the infrastructure for the AstroCloud. Throughout the data of the entire life cycle, data archiving system standardized data, transferring data, logging observational data, archiving ambient data, And storing these data and metadata in database. Quality control covers the whole process and all aspects of data archiving.

He, Boliang; Fan, Dongwei; Li, Changhua; Xiao, Jian; Yu, Ce; Wang, Chuanjun; Cao, Zihuang; Chen, Junyi; Yi, Weimin; Li, Shanshan; Mi, Linying; Yang, Sisi

2014-01-01T23:59:59.000Z

139

Production and Characterization of Plutonium Dioxide Particles as a Quality Control Material for Safeguards Purposes  

Science Journals Connector (OSTI)

Production and Characterization of Plutonium Dioxide Particles as a Quality Control Material for Safeguards Purposes ... Although U particles are of major interest in swipe samples from enrichment facilities, Pu particles are of high interest for safeguarding reactors with hot cells, reprocessing, and research and development facilities. ... The environmental sampling for safeguard (ESS) system is presented, that was useful to monitor trace radioactive pollution in the environment and to detect nuclear activities. ...

Taeko Shinonaga; David Donohue; Helmut Aigner; Stefan Bürger; Dilani Klose; Teemu Kärkelä; Riitta Zilliacus; Ari Auvinen; Olivier Marie; Fabien Pointurier

2012-02-28T23:59:59.000Z

140

File:Colorado Water Quality Control Act.pdf | Open Energy Information  

Open Energy Info (EERE)

Water Quality Control Act.pdf Water Quality Control Act.pdf Jump to: navigation, search File File history File usage Metadata File:Colorado Water Quality Control Act.pdf Size of this preview: 463 × 599 pixels. Other resolution: 464 × 600 pixels. Go to page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 Go! next page → next page → Full resolution ‎(1,275 × 1,650 pixels, file size: 413 KB, MIME type: application/pdf, 69 pages) File history Click on a date/time to view the file as it appeared at that time. Date/Time Thumbnail Dimensions User Comment current 14:23, 14 March 2013 Thumbnail for version as of 14:23, 14 March 2013 1,275 × 1,650, 69 pages (413 KB) Alevine (Talk | contribs)

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Application of a Plantwide Control Design Procedure to a Distillation Column with Heat Pump  

E-Print Network [OSTI]

(Larsson & Skogestad 2001) to a distillation column heat-integrated by using a heatpump. Top-down analysis) and apply it to a distillation column with heatpump. Plantwide control design should start by formulating

Skogestad, Sigurd

142

Pollutant Assessments Group Procedures Manual: Volume 1, Administrative and support procedures  

SciTech Connect (OSTI)

This manual describes procedures currently in use by the Pollutant Assessments Group. The manual is divided into two volumes: Volume 1 includes administrative and support procedures, and Volume 2 includes technical procedures. These procedures are revised in an ongoing process to incorporate new developments in hazardous waste assessment technology and changes in administrative policy. Format inconsistencies will be corrected in subsequent revisions of individual procedures. The purpose of the Pollutant Assessments Groups Procedures Manual is to provide a standardized set of procedures documenting in an auditable manner the activities performed by the Pollutant Assessments Group (PAG) of the Health and Safety Research Division (HASRD) of the Environmental Measurements and Applications Section (EMAS) at Oak Ridge National Laboratory (ORNL). The Procedures Manual ensures that the organizational, administrative, and technical activities of PAG conform properly to protocol outlined by funding organizations. This manual also ensures that the techniques and procedures used by PAG and other contractor personnel meet the requirements of applicable governmental, scientific, and industrial standards. The Procedures Manual is sufficiently comprehensive for use by PAG and contractor personnel in the planning, performance, and reporting of project activities and measurements. The Procedures Manual provides procedures for conducting field measurements and includes program planning, equipment operation, and quality assurance elements. Successive revisions of this manual will be archived in the PAG Document Control Department to facilitate tracking of the development of specific procedures.

Not Available

1992-03-01T23:59:59.000Z

143

Quality control of polymer solar modules by lock-in thermography  

Science Journals Connector (OSTI)

We have characterized lateral imperfections of photovoltaic modules based on solution processed polymer-fullerene semiconductor blends by means of lock-in thermography (LIT). The active layer of the solar cell modules is based on the heterogeneous organic semiconductor system poly(3-hexylthiophene):phenyl- C 61 -butyric acid methyl ester and the power conversion efficiency of the modules reached nearly 2% under irradiation of an AM 1.5 solar simulator. Applying highly sensitive LIT allowed us to detect several kinds of laterally distributed defects originating from imperfections in the respective functional layers as well as in the quality of encapsulation. We show that LIT is a powerful method for the quality control of large area polymersolar cells and modules enabling fast feedback for optimization of production parameters.

Harald Hoppe; Jonas Bachmann; Burhan Muhsin; Karl-Heinz Drüe; Ingo Riedel; Gerhard Gobsch; Claudia Buerhop-Lutz; Christoph J. Brabec; Vladimir Dyakonov

2010-01-01T23:59:59.000Z

144

A Comprehensive Quality Assurance Program for Personnel and Procedures in Radiation Oncology: Value of Voluntary Error Reporting and Checklists  

SciTech Connect (OSTI)

Purpose: This report describes the value of a voluntary error reporting system and the impact of a series of quality assurance (QA) measures including checklists and timeouts on reported error rates in patients receiving radiation therapy. Methods and Materials: A voluntary error reporting system was instituted with the goal of recording errors, analyzing their clinical impact, and guiding the implementation of targeted QA measures. In response to errors committed in relation to treatment of the wrong patient, wrong treatment site, and wrong dose, a novel initiative involving the use of checklists and timeouts for all staff was implemented. The impact of these and other QA initiatives was analyzed. Results: From 2001 to 2011, a total of 256 errors in 139 patients after 284,810 external radiation treatments (0.09% per treatment) were recorded in our voluntary error database. The incidence of errors related to patient/tumor site, treatment planning/data transfer, and patient setup/treatment delivery was 9%, 40.2%, and 50.8%, respectively. The compliance rate for the checklists and timeouts initiative was 97% (P<.001). These and other QA measures resulted in a significant reduction in many categories of errors. The introduction of checklists and timeouts has been successful in eliminating errors related to wrong patient, wrong site, and wrong dose. Conclusions: A comprehensive QA program that regularly monitors staff compliance together with a robust voluntary error reporting system can reduce or eliminate errors that could result in serious patient injury. We recommend the adoption of these relatively simple QA initiatives including the use of checklists and timeouts for all staff to improve the safety of patients undergoing radiation therapy in the modern era.

Kalapurakal, John A., E-mail: j-kalapurakal@northwestern.edu [Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States); Zafirovski, Aleksandar; Smith, Jeffery; Fisher, Paul; Sathiaseelan, Vythialingam [Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States)] [Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States); Barnard, Cynthia [Department of Quality Strategies, Northwestern Memorial Hospital, Chicago, Illinois (United States)] [Department of Quality Strategies, Northwestern Memorial Hospital, Chicago, Illinois (United States); Rademaker, Alfred W. [Department of Preventive Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States)] [Department of Preventive Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States); Rave, Nick [Department of Physicians Services, Northwestern Memorial Hospital, Chicago, Illinois (United States)] [Department of Physicians Services, Northwestern Memorial Hospital, Chicago, Illinois (United States); Mittal, Bharat B. [Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States)] [Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States)

2013-06-01T23:59:59.000Z

145

Project plan: Procedure system design for the Rocky Flats Plant Emergency Preparedness Program  

SciTech Connect (OSTI)

This procedure system is being designed for the Rocky Flats Plant Emergency Preparedness Program (EPP) to: assess the procedural needs of the Emergency Preparedness Program in light of the existing Rocky Flats Plant policies, plans, procedures, and applicable DOE orders; design the structure of the Emergency Preparedness Program procedural system based on the classes of procedures needed, the types of procedures (procedures vs job outline), the sections of procedures required, and the timetable for procedure maintenance; develop boiler plate formats for the various authors in writing the necessary standardized procedures; develop a list of all the necessary procedures that must be produced for Emergency Preparedness Program; and provide consistency for department-wide activities relating to the quality control in writing, distribution, and revising procedures for Emergency Preparedness Program. 23 refs., 18 figs.

Hodgin, C.R.; Brown-Strattan, M.

1989-10-01T23:59:59.000Z

146

Influence of cultural practices on yield, quality and disease control of 'Chenin Blanc' grapes in Southeast Texas  

E-Print Network [OSTI]

INFLUENCE OF CULTURAL PRACTICES ON YIELD, QUALITY AND DISEASE CONTROL OF 'CHENIN BLANC' GRAPES IN SOUTHEAST TEXAS A Thesis by IVA SUZANNE WILSON Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment... on Yield, Quality and Disease Control of 'Chenin Blanc' Grapes in Southeast Texas. (December 1989) Iva Suzanne Wilson, B. S. , Southwest Texas State University Co-Chair of Advisory Committee: J. Dan Hanna George Ray McEachern Canopy management...

Wilson, Iva Suzanne

1989-01-01T23:59:59.000Z

147

Method of controlling coherent synchroton radiation-driven degradation of beam quality during bunch length compression  

SciTech Connect (OSTI)

A method of avoiding CSR induced beam quality defects in free electron laser operation by a) controlling the rate of compression and b) using a novel means of integrating the compression with the remainder of the transport system: both are accomplished by means of dispersion modulation. A large dispersion is created in the penultimate dipole magnet of the compression region leading to rapid compression; this large dispersion is demagnified and dispersion suppression performed in a final small dipole. As a result, the bunch is short for only a small angular extent of the transport, and the resulting CSR excitation is small.

Douglas, David R. (Newport News, VA); Tennant, Christopher D. (Williamsburg, VA)

2012-07-10T23:59:59.000Z

148

Quality assurance guidance for TRUPACT-II (Transuranic Package Transporter-II) payload control  

SciTech Connect (OSTI)

The Transuranic Package Transporter-II (TRUPACT-II) Safety Analysis Report for Packaging (SARP) approved by the Nuclear Regulatory Commission (NRC), discusses authorized methods for payload control in Appendix 1.3.7 and the Quality Assurance (QA) requirements in Section 9.3. Subsection 9.3.2.1 covers maintenance and use of the TRUPACT-II and the specific QA requirements are given in DOE/WIPP 89-012. Subsection 9.3.2.2 covers payload compliance, for which this document was written. 6 refs.

Not Available

1989-10-01T23:59:59.000Z

149

Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements  

E-Print Network [OSTI]

The Neutrino Experiment with a Xenon TPC (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds. An extensive screening and material selection process is underway for NEXT since the control of the radiopurity levels of the materials to be used in the experimental set-up is a must for rare event searches. First measurements based on Glow Discharge Mass Spectrometry and gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterr\\'aneo de Canfranc (Spain) are described here. Activity results for natural radioactive chains and other common radionuclides are summarized, being the values obtained for some materials like copper and stainless steel very competitive. The implications of these results for the NEXT experiment are also discussed.

Alvarez, V; Bettini, A; Borges, F I G M; Carcel, S; Castel, J; Catala, J M; Cebrian, S; Cervera, A; Conde, C A N; Dafni, T; Dias, T H V T; Diaz, J; Egorov, M; Esteve, R; Evtoukhovitch, P; Fernandes, L M P; Ferrario, P; Ferreira, A L; Ferrer-Ribas, E; Freitas, E D C; Gehman, V M; Gil, A; Giomataris, I; Goldschmidt, A; Gomez, H; Gomez-Cadenas, J J; Gonzalez, K; Gonzalez-Diaz, D; Gutierrez, R M; Hauptman, J; Morata, J A Hernando; Herrera, D C; Herrero, V; Iguaz, F J; Irastorza, I G; Kalinnikov, V; Labarga, L; Liubarsky, I; Lopes, J A M; Lorca, D; Losada, M; Luzon, G; Mari, A; Martin-Albo, J; Martinez, A; Miller, T; Moiseenko, A; Monrabal, F; Monteiro, C M B; Monzo, J M; Mora, F J; Moutinho, L M; Vidal, J Munoz; da Luz, H Natal; Navarro, G; Nebot, M; Nygren, D; Oliveira, C A B; de Solorzano, A Ortiz; Palma, R; Perez, J; Aparicio, J L Perez; Renner, J; Ripoll, L; Rodriguez, A; Rodriguez, J; Santos, F P; Santos, J M F dos; Segui, L; Serra, L; Shuman, D; Simon, A; Sofka, C; Sorel, M; Toledo, J F; Tomas, A; Torrent, J; Tsamalaidze, Z; Vazquez, D; Velicheva, E; Veloso, J F C A; Villar, J A; Webb, R C; Weber, T; White, J; Yahlali, N

2012-01-01T23:59:59.000Z

150

Control strategies for mitigation of oil-shale-related-water quality concerns  

SciTech Connect (OSTI)

A comprehensive study of in situ retorting at the Logan Wash has indicated the importance of developing baseline information including raw shale characterization, the elucidation of mineralogical and chemical controls on trace element mobilities from shales subjected to in situ processing, and the research necessary to identify strategies for control of recognized environmental impacts. It is impossible to assess the magnitude of trace element releases to be expected from a commercial in situ facility once banks of retorts or the entire facility is abandoned and dewatering of the area is concluded. However, laboratory-scale studies can indeed identify the relative environmental acceptability of spent shale materials generated by in situ processing. In this research, an attempt was made to relate mineralogy and leaching behavior of field-generated materials with leachate composition and solution chemical processes. The interaction of these factors will ultimately affect the impact of in situ processing on surface and groundwater quality.

Peterson, E.J.; Wagner, P.

1981-01-01T23:59:59.000Z

151

Computerized procedures system  

SciTech Connect (OSTI)

An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

Lipner, Melvin H. (Monroeville, PA); Mundy, Roger A. (North Huntingdon, PA); Franusich, Michael D. (Upper St. Clair, PA)

2010-10-12T23:59:59.000Z

152

Measurement and control of brake pedal feel quality in automobile manufacturing  

E-Print Network [OSTI]

Customer perception of brake pedal feel quality, as related to the perception of the brake pedal feeling soft or mushy, depends on both the customer's subjective judgment of quality and the actual build quality of the brake ...

Cerilles, Jeffrey T. (Jeffrey Thomas)

2005-01-01T23:59:59.000Z

153

EERE Quality Control Workshop Final Report: Proceedings from the EERE Quality Control Workshop, in support of the DOE Clean Energy Manufacturing Initiative; Golden, Colorado, December 9-10, 2013  

SciTech Connect (OSTI)

The U.S. Department of Energy Office of Energy Efficiency & Renewable Energy (EERE) has recognized the cross-cutting, pre-competitive and enabling nature of quality control for a wide range of clean energy technologies. As such, the Fuel Cell Technologies Office, Solar Energy Technologies Office, Vehicle Technologies Office, Building Technologies Office, and Advanced Manufacturing Office decided to explore needs and potential cross-office synergies in this area by holding the EERE Quality Control Workshop, in support of the DOE Clean Energy Manufacturing Initiative. This report summarizes the purpose and scope of the workshop; reviews the current status and state-of-the-art for in-line quality control; summarizes the results from three breakout sessions; and presents conclusions and recommendations.

Not Available

2014-05-01T23:59:59.000Z

154

Controllable high-quality electron beam generation by phase slippage effect in layered targets  

E-Print Network [OSTI]

The bubble structure generated by laser and plasma interactions changes in size depending on the local plasma density. The self injection electrons position with respect to wakefield can be controlled by tailoring the longitudinal plasma density. A regime to enhance the energy of the wakefield accelerated electrons and improve the beam quality is proposed and achieved using layered plasmas with increasing densities. Both the wakefield size and the electron bunch duration are significantly contracted in this regime. The electrons remain in the strong acceleration phase of the wakefield while their energy spread decreases because of their tight spatial distribution. An electron beam of 0.5GeV with less than 0.01 energy spread is obtained through 2.5D PIC simulations.

Yu, Q; Li, X F; Huang, S; Zhang, F; Kong, Q; Ma, Y Y; Kawata, S

2014-01-01T23:59:59.000Z

155

SU?E?T?377: Evaluation and Implementation of An IMRT Quality Assurance Procedure to Include Patient?Specific Volumetric Dose Analysis  

Science Journals Connector (OSTI)

Purpose: he purpose of this study is to evaluate and implement a digital IMRT quality assurance (QA) procedure for patient?specific volumetric dose using commercially available products. Dose distributions generated from a treatment planning system (TPS) were delivered and analyzed with dose?volume?histogram (DVH) analysis software. Methods: The MapCheck2 device along with 3DVH (Sun Nuclear Melbourne FL) software was studied for IMRT QA capabilities. All manufacturer specifications were followed in order to properly set up the diode array device for accurate absolute dose measurements. Planar dose maps were generated by the Pinnacle3 TPS (Philips Medical Systems Andover MA) for field?by?field IMRT QA analysis. Also exported from patient plans were RT dose RT plan RT structure and CT data DICOM files. Dose delivery was done using a step?and?shoot en?face technique onto the MapCheck2 device. After measured?vs?calculated planar dose analysis for each beam a planned?dose?perturbation (PDP™) file was generated. This PDP file allows the software to manipulate the TPS?calculated dose distributions to include actual measured dose differences from a phantom onto a patient CT?dataset. These dose perturbations are then able to be observed through differences of a TPS?calculated DVH and a measured?DVH within the 3DVH software. Simple tests were performed to assess MapCheck2 performance and 3DVH sensitivity to errors. Results: All planar dose measurements in this study have met the clinical tolerance of 3% absolute dose/3mm gamma analysis. For volumetric analysis the 3D results comparing planned?vs?delivered matching doses (gamma criterion of 3%/3mm) were 99.3% and 98.2% for a rectum and prostate plan respectively. Measurements with introduction of intentional errors produced reasonable results when analyzing dose to critical structures with DVHs. Conclusion: The implementation of a digital QA procedure will facilitate a more efficient workflow for physicists with the added benefit of a patient?specific volumetric dose analysis for physicians.

2013-01-01T23:59:59.000Z

156

Mise en oeuvre du contrle de qualit d'une camra TEMP-TDM Quality control of hybrid SPECT-TDM  

E-Print Network [OSTI]

qualité, activimètre, dosimétrie Abstract : Like many nuclear medicine center, the decision of November 25, and even in some cases nothing was done. Our experience in quality control in nuclear medicine these controls. Key words : SPECT-CT, gamma camera, quality control, dose calibrator, dosimetry hal-00458358

Paris-Sud XI, Université de

157

Abstract 730: A prototype device for quality control of cancer specimens.  

Science Journals Connector (OSTI)

...fat. We measured diet quality with the Healthy Eating...29-32), which uses an energy-adjusted density approach...mechanism by which diet quality could affect survival, regardless of age, energy intake, BMI, recreational...associations between diet quality and SAA, leptin, or...

Jie Li; Catherine Kil; Jia Sun; Michael Stankewich; and Alexander O. Vortmeyer

2013-04-15T23:59:59.000Z

158

PROTEIN QUALITY CONTROL IN BACTERIAL CELLS: INTEGRATED NETWORKS OF CHAPERONES AND ATP-DEPENDENT PROTEASES.  

SciTech Connect (OSTI)

It is generally accepted that the information necessary to specify the native, functional, three-dimensional structure of a protein is encoded entirely within its amino acid sequence; however, efficient reversible folding and unfolding is observed only with a subset of small single-domain proteins. Refolding experiments often lead to the formation of kinetically-trapped, misfolded species that aggregate, even in dilute solution. In the cellular environment, the barriers to efficient protein folding and maintenance of native structure are even larger due to the nature of this process. First, nascent polypeptides must fold in an extremely crowded environment where the concentration of macromolecules approaches 300-400 mg/mL and on average, each ribosome is within its own diameter of another ribosome (1-3). These conditions of severe molecular crowding, coupled with high concentrations of nascent polypeptide chains, favor nonspecific aggregation over productive folding (3). Second, folding of newly-translated polypeptides occurs in the context of their vehtorial synthesis process. Amino acids are added to a growing nascent chain at the rate of {approx}5 residues per set, which means that for a 300 residue protein its N-terminus will be exposed to the cytosol {approx}1 min before its C-terminus and be free to begin the folding process. However, because protein folding is highly cooperative, the nascent polypeptide cannot reach its native state until a complete folding domain (50-250 residues) has emerged from the ribosome. Thus, for a single-domain protein, the final steps in ffolding are only completed post-translationally since {approx}40 residues of a nascent chain are sequestered within the exit channel of the ribosome and are not available for folding (4). A direct consequence of this limitation in cellular folding is that during translation incomplete domains will exist in partially-folded states that tend to expose hydrophobic residues that are prone to aggregation and/or mislfolding. Thus it is not surprising that, in cells, the protein folding process is error prone and organisms have evolved ''editing'' or quality control (QC) systems to assist in the folding, maintenance and, when necessary, selective removal of damaged proteins. In fact, there is growing evidence that failure of these QC-systems contributes to a number of disease states (5-8). This chapter describes our current understanding of the nature and mechanisms of the protein quality control systems in the cytosol of bacteria. Parallel systems are exploited in the cytosol and mitochondria of eukaryotes to prevent the accumulation of misfolded proteins.

FLANAGAN,J.M.BEWLEY,M.C.

2002-10-01T23:59:59.000Z

159

PROTEIN QUALITY CONTROL IN BACTERIAL CELLS: INTEGRATED NETWORKS OF CHAPERONES AND ATP-DEPENDENT PROTEASES.  

SciTech Connect (OSTI)

It is generally accepted that the information necessary to specify the native, functional, three-dimensional structure of a protein is encoded entirely within its amino acid sequence; however, efficient reversible folding and unfolding is observed only with a subset of small single-domain proteins. Refolding experiments often lead to the formation of kinetically-trapped, misfolded species that aggregate, even in dilute solution. In the cellular environment, the barriers to efficient protein folding and maintenance of native structure are even larger due to the nature of this process. First, nascent polypeptides must fold in an extremely crowded environment where the concentration of macromolecules approaches 300-400 mg/mL and on average, each ribosome is within its own diameter of another ribosome (1-3). These conditions of severe molecular crowding, coupled with high concentrations of nascent polypeptide chains, favor nonspecific aggregation over productive folding (3). Second, folding of newly-translated polypeptides occurs in the context of their vehtorial synthesis process. Amino acids are added to a growing nascent chain at the rate of -5 residues per set, which means that for a 300 residue protein its N-terminus will be exposed to the cytosol {approx}1 min before its C-terminus and be free to begin the folding process. However, because protein folding is highly cooperative, the nascent polypeptide cannot reach its native state until a complete folding domain (50-250 residues) has emerged from the ribosome. Thus, for a single-domain protein, the final steps in folding are only completed post-translationally since {approx}40 residues of a nascent chain are sequestered within the exit channel of the ribosome and are not available for folding (4). A direct consequence of this limitation in cellular folding is that during translation incomplete domains will exist in partially-folded states that tend to expose hydrophobic residues that are prone to aggregation and/or misfolding. Thus it is not surprising that, in cells, the protein folding process is error prone and organisms have evolved ''editing'' or quality control (QC) systems to assist in the folding, maintenance and, when necessary, selective removal of damaged proteins. In fact, there is growing evidence that failure of these QC-systems contributes to a number of disease states (5-8). This chapter describes our current understanding of the nature and mechanisms of the protein quality control systems in the cytosol of bacteria. Parallel systems are exploited in the cytosol and mitochondria of eukaryotes to prevent the accumulation of misfolded proteins.

FLANAGAN,J.M.; BEWLEY,M.C.

2001-12-03T23:59:59.000Z

160

Data quality assurance controls through the WIPP (Waste Isolation Pilot Plant) In Situ Data Acquisition, Analysis, and Management System  

SciTech Connect (OSTI)

Assurance of data quality for the in situ tests fielded at the Waste Isolation Pilot Plant is of critical importance. These tests supply the information for development and verification of the technology required for construction of a radioactive waste repository in bedded salt. The tests are some of the largest ever fielded in an underground facility. To assure that the extensive output generated by the tests is compatible with the high standards of quality required, a major project task was undertaken for the acquisition, control, and preservation of the all the associated in situ test databases, with the principal emphasis on the very large thermal/structural in situ tests. In order to accomplish this task the WIPP In Situ Data Acquisition, Analysis, and Management (WISDAAM) System was put into place. The system provides for quality control of the test databases and certified test data throughout the duration of the tests. 13 refs., 14 figs., 3 tabs.

Munson, D.E. (Sandia National Labs., Albuquerque, NM (USA)); Ball, J.R. (RE/SPEC, Inc., Albuquerque, NM (USA)); Jones, R.L. (Tech. Reps., Inc., Albuquerque, NM (USA))

1990-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Results of The Excreta Bioassay Quality Control Program For April 1, 2010 Through March 31, 2011  

SciTech Connect (OSTI)

A total of 76 urine samples and 10 spiked fecal samples were submitted during the report period (April 1, 2010 through March 31, 2011) to GEL Laboratories, LLC in South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for 14C, Sr, for 238Pu, 239Pu, 241Am, 243Am, 235U, 238U, 238U-mass and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.1% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 31% of the analyses processed by GEL during the first year of contract 112512 were quality control samples. GEL tested the performance of 23 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty except the slightly elevated relative bias for 243,244Cm (Table 4).

Antonio, Cheryl L.

2012-07-19T23:59:59.000Z

162

Pilot Quality Control Program for Audit RT External Beams at Mexican Hospitals  

SciTech Connect (OSTI)

A pilot quality control program for audit 18 radiotherapy RT external beams at 13 Mexican hospitals is described--for eleven {sup 60}Co beams and seven photon beams of 6, 10 and 15 MV from accelerators. This program contains five parts: a) Preparation of the TLD-100 powder: washing, drying and annealing (one hour 400 deg. C plus 24 hrs 80 deg. C). b) Sending two IAEA type capsules to the hospitals for irradiation at the hospital to a nominal D{sub W} = 2 Gy{center_dot}c) Preparation at the SSDL of ten calibration curves CC in the range of 0.5 Gy to 6 Gy in terms of absorbed dose to water D{sub W} for {sup 60}Co with traceability to primary laboratory NRC (Canada), according to a window irradiation: 26/10/2007-7/12/2007. d) Reading all capsules that match their hospital time irradiation and the SSDL window irradiation. f) Evaluation of the Dw imparted by the hospitals.

Alvarez R, J T; Tovar M, V M [Secondary Standard Dosimetry Laboratory SSDL, Ionizing Radiation Metrology Department, ININ Carretera Federal Mexico Toluca S/N, La Marquesa, Ocoyoacac, Estado de Mexico 52 750 (Mexico)

2008-08-11T23:59:59.000Z

163

Procedures for Public Release of Data | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Procedures for Public Release of Data Procedures for Public Release of Data Procedures for Public Release of Data Procedures for Public Release of Data All Department of Energy (DOE) data owners should follow the procedures outlined below in preparing a data collection for public release. Legislative requirements, Office of Management and Budget (OMB) guidance, and DOE directives related to data quality and data control are referenced in the procedures steps. Step 1 Data owners and/or managers identify a data collection for possible public release. The following initial reviews are performed at the Administration or Program Office level by data owners in conjunction with appropriate staff (classifiers, records managers, privacy managers, and General Counsel among others) to determine if the data collection is

164

A Protocol for Quality Control Testing for Contrast-Enhanced Dual Energy Mammography Systems  

Science Journals Connector (OSTI)

Physics and radiographer QC procedures are urgently needed as the first few contrast-enhanced dual energy systems have been installed in the U.K. Preliminary work on one commercially available system has enabl...

Jennifer Oduko; Peter Homolka; Vivienne Jones; David Whitwam

2014-01-01T23:59:59.000Z

165

Economically Efficient Operation of CO2 Capturing Process Part I: Self-optimizing Procedure for Selecting the Best Controlled Variables  

E-Print Network [OSTI]

the greenhouse gas CO2 that causes global warming. Due to the effect of CO2 emissions on global warming consider an absorption/stripping amine process to remove most of the CO2 from the combustion flue gas Efficient Operation of CO2 Capturing Process Part I: Self-optimizing Procedure for Selecting the Best

Skogestad, Sigurd

166

Data Quality Assessment and Control for the ARM Climate Research Facility  

SciTech Connect (OSTI)

The mission of the Atmospheric Radiation Measurement (ARM) Climate Research Facility is to provide observations of the earth climate system to the climate research community for the purpose of improving the understanding and representation, in climate and earth system models, of clouds and aerosols as well as their coupling with the Earth's surface. In order for ARM measurements to be useful toward this goal, it is important that the measurements are of a known and reasonable quality. The ARM data quality program includes several components designed to identify quality issues in near-real-time, track problems to solutions, assess more subtle long-term issues, and communicate problems to the user community.

Peppler, R

2012-06-26T23:59:59.000Z

167

Factors controlling reservoir quality in tertiary sandstones and their significance to geopressured geothermal production  

SciTech Connect (OSTI)

Variable intensity of diagenesis is the factor primarily responsible for contrasting regional reservoir quality of Tertiary sandstones from the upper and lower Texas coast. Detailed comparison of Frio sandstone from the Chocolate Bayou/Danbury Dome area, Brazoria County, and Vicksburg sandstones from the McAllen Ranch Field area, Hidalgo County, reveals that extent of diagenetic modification is most strongly influenced by (1) detrital mineralogy and (2) regional geothermal gradients. The regional reservoir quality of Frio sandstones from Brazoria County is far better than that characterizing Vicksburg sandstones from Hidalgo County, especially at depths suitable for geopressured geothermal energy production. However, in predicting reservoir quality on a site-specific basis, locally variable factors such as relative proportions for porosity types, pore geometry as related to permeability, and local depositional environment must also be considered. Even in an area of regionally favorable reservoir quality, such local factors can significantly affect reservoir quality and, hence, the geothermal production potential of a specific sandstone unit.

Loucks, R.G.; Richmann, D.L.; Milliken, K.L.

1981-01-01T23:59:59.000Z

168

Multi-level feedback control for Quality of Service Management Tommaso Cucinotta, Giuseppe Lipari  

E-Print Network [OSTI]

Palopoli and Luca Abeni are with Universit`a di Trento, Trento, Italy §Rodrigo Santos is with Universidad {t.cucinotta, g.lipari}@sssup.it Luigi Palopoli, Luca Abeni {l.palopoli, l.abeni}@unitn.it Rodrigo Santos§ ierms@criba.edu.ar Abstract We consider the problem of power-aware Quality of Ser- vice (Qo

Lipari, Giuseppe

169

Analysis of results obtained using the automatic chemical control of the quality of the water heat carrier in the drum boiler of the Ivanovo CHP-3 power plant  

Science Journals Connector (OSTI)

Results of industrial tests of the new method used for the automatic chemical control of the quality of boiler water of the drum-type power boiler (P d = 13.8 MPa) are described. The possibility o...

A. B. Larin; A. V. Kolegov

2012-10-01T23:59:59.000Z

170

An automatic acquisition/quality control/fast delivery software for real time follow-up of data coming from a tide gauge network  

E-Print Network [OSTI]

software Sensors survey is already operational on the LEGOS intranet Web site. Quality control will soon characteristics #12;Processing program is based on modules written in Perl language. It gives the possibility

171

Optimal control of investments for quality of supply improvement in electrical energy distribution networks  

Science Journals Connector (OSTI)

This paper considers the problem of deciding multi-period investments for maintenance and upgrade of electrical energy distribution networks. After describing the network as a constrained hybrid dynamical system, optimal control theory is applied to ... Keywords: Hybrid systems, Investment planning, Mixed-integer programming, Optimal control, Stochastic systems

A. Bemporad; D. Muñoz de la Peña; P. Piazzesi

2006-08-01T23:59:59.000Z

172

Experiences on the Implementation of the 'Energy Balance' Methodology as a Data Quality Control Tool: Application to the Building Energy Consumption of a Large University Campus  

E-Print Network [OSTI]

EXPERIENCES ON THE IMPLEMENTATION OF THE “ENERGY BALANCE” METHODOLOGY AS A DATA QUALITY CONTROL TOOL: APPLICATION TO THE BUILDING ENERGY CONSUMPTION OF A LARGE UNIVERSITY CAMPUS Juan-Carlos Baltazar 1 , Ph.D. Research Associate Daniel... allow the engineers to identify and assess commissioning opportunities confidently. This paper presents the application of an innovative data screening methodology as a data quality control tool for energy consumption data. The methodology has...

Baltazar-Cervantes, J. C.; Sakurai, Y.; Masuda, H.; Feinauer, D.; Liu, J.; Ji, J.; Claridge, D. E.; Deng, S.; Bruner, H.

2007-01-01T23:59:59.000Z

173

The mineral content of water as a variable in the quality control of reconstituted non-fat dry milk products  

E-Print Network [OSTI]

LibK?ARr '< A 4 M CuLLEftE ?F TEXAf. THE MINERAL CONTENT OF WATER AS A VARIABLE IN THE QUALITY CONTROL OF RECONSTITUTED NONFAT DRY MILK PRODUCTS By JOHN 0. KAPSAUS A Dissertation Submitted to the Graduate School of the Agricultural...). This is the CO2 evolved in the milk, which has been reconstituted with the respective level of bicarbonate water, in the uninoculated tube. (E) CO2 produced from the action of the apparent milk acidity on the bicarbonate. This is the CO2 calculated from...

Kapsalis, John G.

2013-10-04T23:59:59.000Z

174

Power Quality/Harmonic Detection: Harmonic Control in Electric Power Systems for the Telecommunications Industry  

E-Print Network [OSTI]

The control of harmonics in power systems continues to be a major concern in the telecommunications industry. AC/DC telecommunication conversion equipment has rarely been thought of as playing a major role in the harmonic interaction problem. Yet...

Felkner, L. J.; Waggoner, R. M.

175

Development of Data Quality Control Limits for Data Screening through the "Energy Balance" Method  

E-Print Network [OSTI]

over/underestimation in energy use and increase accuracy in further analysis. It allows engineers and administrators to make more confident and low-risk decisions. This paper proposes a methodology to construct statistical control limits for data...

Masuda, H.; Baltazar, J. C.; Ji, J.; Claridge, D.

176

Controlling Small Fixed Wing UAVs to Optimize Image Quality from On-Board Cameras  

E-Print Network [OSTI]

1.3.2 Arduino Autopilot . . . . . . . . . 1.3.3 HILsafe location to loiter. Arduino Autopilot The Ardupilot isis a variation of the Arduino Mega micro controller, with a

Jackson, Stephen Phillip

2011-01-01T23:59:59.000Z

177

Apparatus and procedure to characterize the surface quality of conductors by measuring the rate of cathode emission as a function of surface electric field strength  

DOE Patents [OSTI]

A device and method for characterizing quality of a conducting surface. The device including a gaseous ionizing chamber having centrally located inside the chamber a conducting sample to be tested to which a negative potential is applied, a plurality of anode or "sense" wires spaced regularly about the central test wire, a plurality of "field wires" at a negative potential are spaced regularly around the sense, and a plurality of "guard wires" at a positive potential are spaced regularly around the field wires in the chamber. The method utilizing the device to measure emission currents from the conductor.

Mestayer, Mac; Christo, Steve; Taylor, Mark

2014-10-21T23:59:59.000Z

178

Purchasing Policy and Procedures Page 1 Purchasing Policy and Procedures  

E-Print Network [OSTI]

Controller Responsible Offices: Purchasing Resource Services Controller's Office Origination Date: December 1Purchasing Policy and Procedures Page 1 4-1-2010 Purchasing Policy and Procedures Policy Statement are followed. Purchasing Resource Services (PRS), which is part of University Services, is the single point

Shahriar, Selim

179

Procedural Safeguards  

Science Journals Connector (OSTI)

Procedural Safeguards are protections afforded by the Individuals with...2004...(IDEIA) to each student with a disability and to his or her parents to ensure that the student receives a free and appropriate publi...

Debra Dunn Esq.

2013-01-01T23:59:59.000Z

180

Influences of Additives on Steam Gasification of Biomass. 1. Pyrolysis Procedure  

Science Journals Connector (OSTI)

To remove tar and upgrade the quality of gaseous product, researchers have extensively studied the influences of various additives(2-6) and diverse reactors(7-9) on biomass gasification. ... For the pyrolysis procedure, there are two effectual methods, improving operating conditions and adding additives into reactors, to control the formations of tar and CnHm. ... The chemical components of additives added in the related pyrolysis procedure are shown in Table 2. ...

Yu R. Xie; Lai H. Shen; Jun Xiao; Da X. Xie; Jing Zhu

2009-09-23T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Quality-Controlled Upper-Air Sounding Dataset for DYNAMO/CINDY/AMIE: Development and Corrections  

SciTech Connect (OSTI)

The upper-air sounding network for DYNAMO (Dynamics of the Madden-Julian Oscillation or MJO) has provided an unprecedented set of observations for studying the MJO over the Indian Ocean (IO) where coupling of this oscillation with deep convection first occurs. With 72 sounding sites and dropsonde data from 13 aircraft mission, the sonde network covers the tropics from Eastern African to the West Pacific. In total nearly 26,000 sondes were collected from this network during the experiment’s 6-month extended observing period (from October 2011 to March 2012). Slightly more than half of the sondes, collected from 33 sites, are at high vertical resolution. Rigorous post-field phase processing of the sonde data included several levels of quality checks and a variety of corrections which address a number of issues (e.g., daytime dry bias, baseline surface data errors, ship deck-heating effects, artificial dry spikes in slow ascent sondes). Because of the importance of an accurate description of the moisture field in meeting the scientific goals of the experiments, particular attention is given to humidity correction and its validation. The humidity corrections, though small relative to some previous field campaigns, produced high fidelity moisture analyses in which sonde precipitable water compared well with independent estimates. An assessment of model operational analyses moisture using corrected sonde data shows an overall good agreement with the exception at upper-levels where model moisture and clouds are more abundant than the sounding data would indicate.

Ciesielski, Paul; Yu, Hungjui; Johnson, Richard; Yoneyama, Kunio; Katsumata, Masaki; Long, Charles N.; Wang, Junhong; Loehrer, Scot; Young, Kate; Williams, S.; Brown, William; Braun, John; Van Hove, Terese

2014-04-01T23:59:59.000Z

182

Surface photovoltage method for the quality control of silicon epitaxial layers on sapphire  

SciTech Connect (OSTI)

The surface photovoltage method is used to study “silicon-on-sapphire” epitaxial layers with a thickness of 0.3–0.6 ?m, which are used to fabricate p-channel MOS (metal—oxide-semiconductor) transistors with improved radiation hardness. It is shown that the manner in which the photoconductivity of the epitaxial layer decays after the end of a light pulse generated by a light-emitting diode (wavelength ?400 nm) strongly depends on the density of structural defects in the bulk of the structure. This enables control over how a “silicon-on-sapphire” structure is formed to provide the manufacturing of MOS structures with optimal operating characteristics.

Yaremchuk, A. F.; Starkov, A. V.; Zaikin, A. V., E-mail: lynch0000@gmail.com [National Rsearch University MIET (Russian Federation); Alekseev, A. V. [ZAO “Telekom-STV” (Russian Federation); Sokolov, E. M. [ZAO “Epiel” (Russian Federation)

2014-12-15T23:59:59.000Z

183

Scanning ARM Cloud Radars Part II: Data Quality Control and Processing  

SciTech Connect (OSTI)

The Scanning ARM Cloud Radars (SACR’s) are the primary instruments for documenting the four-dimensional structure and evolution of clouds within a 20-30 km radius from the ARM fixed and mobile sites. Here, the post-processing of the calibrated SACR measurements is discussed. First, a feature mask algorithm that objectively determines the presence of significant radar returns is described. The feature mask algorithm is based on the statistical properties of radar receiver noise. It accounts for atmospheric emission and is applicable even for SACR profiles with few or no signal-free range gates. Using the nearest-in-time atmospheric sounding, the SACR radar reflectivities are corrected for gaseous attenuation (water vapor and oxygen) using a line-by-line absorption model. Despite having a high pulse repetition frequency, the SACR has a narrow Nyquist velocity limit and thus Doppler velocity folding is commonly observed. An unfolding algorithm that makes use of a first guess for the true Doppler velocity using horizontal wind measurements from the nearest sounding is described. The retrieval of the horizontal wind profile from the Hemispherical Sky – Range Height Indicator SACR scan observations and/or nearest sounding is described. The retrieved horizontal wind profile can be used to adaptively configure SACR scan strategies that depend on wind direction. Several remaining challenges are discussed, including the removal of insect and second-trip echoes. The described algorithms significantly enhance SACR data quality and constitute an important step towards the utilization of SACR measurements for cloud research.

Kollias, Pavlos; Jo, Ieng; Borque, Paloma; Tatarevic, Aleksandra; Lamer, Katia; Bharadwaj, Nitin; Widener, Kevin B.; Johnson, Karen; Clothiaux, Eugene E.

2014-03-01T23:59:59.000Z

184

The Effects of Quality Control on Decreasing Error Propagation in the LandScan USA Population Distribution Model: A Case Study of Philadelphia County  

SciTech Connect (OSTI)

Landscan USA is a high resolution dasymetric model incorporating multiple ancillary variables to distribute populations. LandScan USA is a valuable tool in determining the population at risk during emergency response situations. However, a critical evaluation is necessary to produce user confidence regarding model accuracy through the verification and validation of model outputs. Unfortunately, dynamic models, such as population distribution, are often not validated due to the difficulty of having multiple input datasets and lack of validated data. A validated dataset allows analysis of model accuracy, as well as quantifying the benefits and costs of improving input datasets compared to find a balance for producing the best model. This paper examines inaccuracies present within the input variables of two national school datasets incorporated in the model. Schools were chosen since a validated school dataset exists for Philadelphia County, Pennsylvania. Quality control efforts utilized throughout the LandScan USA process are quantified to determine the degree of quality control necessary to have a statistically significant effect on model output. Typical LandScan USA quality control resulted in 43% of school enrollment values changed, compared to 89% for the validated dataset. Normal quality control methods resulted in 36% of schools being spatially relocated compared to 87% for the validated dataset. However, the costs of increasing quality control from normal to the validated dataset equated to a 600% increase in manual labor time for statistically insignificant improvements in LandScan USA daytime. This study enabled validation verification of not only the quality control process for LandScan USA, but also provides confidence in model output and use for policy issues, planning and emergency situations.

Patterson, Lauren [University of North Carolina, Chapel Hill; Urban, Marie L [ORNL; Myers, Aaron T [ORNL; Bhaduri, Budhendra L [ORNL; Bright, Eddie A [ORNL; Coleman, Phil R [ORNL

2009-01-01T23:59:59.000Z

185

ARM - Data Quality Program  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Quality Program Quality Program DQ Resources Data Quality Assessment and Control Report (PDF, 747KB) Data Quality Office Data Quality Problem Reporting (DQPR) Contact Us Submit Data Quality Findings Randy Peppler, Data Quality Manager Ken Kehoe, Data Quality Specialist Justin Monroe, Data Quality Specialist Adam Theisen, Data Quality Specialist Sean Moore, Data Quality Consultant Instrument and Site Contacts Instrument Mentors AAF Contacts AMF Contacts NSA Site Contacts SGP Site Contacts TWP Site Contacts Data Quality Program Introduction One of the goals of the ARM Climate Research Facility is to provide datastreams of quality suitable for scientific research. Maintaining data quality for an organization program of the size and complexity of the ARM Facility is a significant challenge; efforts toward this end have matured

186

Procedures - 88-Inch Cyclotron  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Procedures Procedures (You must be logged in with your Berkeley Lab LDAP to view the procedures) PUB-3000...

187

Department of EneDepartment of Energy Quality Assurance: Design Control for the Waste Treatment and Immobilization Plant at the Hanford Sitergy  

Broader source: Energy.gov (indexed) [DOE]

Department of Energy Quality Department of Energy Quality Assurance: Design Control for the Waste Treatment and Immobilization Plant at the Hanford Site DOE/IG-0894 September 2013 U.S. Department of Energy Office of Inspector General Office of Audits and Inspections Department of Energy Washington, DC 20585 September 30, 2013 MEMORANDUM FOR THE SECRETARY FROM: Gregory H. Friedman Inspector General SUBJECT: INFORMATION: Audit Report on "Department of Energy Quality Assurance: Design Control for the Waste Treatment and Immobilization Plant at the Hanford Site" INTRODUCTION AND OBJECTIVE The Department of Energy is constructing the $12.2 billion Waste Treatment and Immobilization Plant (WTP) to vitrify approximately 56 million gallons of radioactive and chemically hazardous

188

Test Procedure Conducted Energy Weapons  

E-Print Network [OSTI]

Test Procedure for Conducted Energy Weapons Version 1.1 2010/07/31 #12;Contents Page 0.0 Disclaimer A TASER M26 13 Appendix B TASER X26 23 #12;1 Test Procedure for Conducted Energy Weapons 0.0 Disclaimer Energy Weapons ("CEWs") in a controlled and repeatable manner across jurisdictions. The consistent

Adler, Andy

189

Evaluation of Quality-Assurance/Quality-Control Data Collected by the U.S. Geological Survey from Wells and Springs between the Southern Boundary of the Idaho National Engineering and Environmental Laboratory and the Hagerman Area, Idaho, 1989 through 1995  

SciTech Connect (OSTI)

The U.S. Geological (USGS) and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, collected and analyzed water samples to monitor the water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area, Idaho. Concurrently, replicate samples and blank samples were collected and analyzed as part of the quality-assurance/quality-control program. Samples were analyzed from inorganic constituents, gross radioactivity and radionuclides, organic constituents, and stable isotopes. To evaluate the precision of field and laboratory methods, analytical results of the water-quality and replicate samples were compared statistically for equivalence on the basis of the precision associated with each result. Statistical comparisons of the data indicated that 95 percent of the results of the replicate pairs were equivalent. Blank-sample analytical results indicated th at the inorganic blank water and volatile organic compound blank water from the USGS National Water Quality Laboratory and the distilled water from the Idaho Department of Water Resources were suitable for blanks; blank water from other sources was not. Equipment-blank analytical results were evaluated to determine if a bias had been introduced and possible sources of bias. Most equipment blanks were analyzed for trace elements and volatile organic compounds; chloroform was found in one equipment blank. Two of the equipment blanks were prepared after collection and analyses of the water-quality samples to determine whether contamination had been introduced during the sampling process. Results of one blank indicated that a hose used to divert water away from pumps and electrical equipment had contaminated the samples with some volatile organic compounds. Results of the other equipment blank, from the apparatus used to filter dissolved organic carbon samples, indicated that the filtering apparatus did not affect water-quality samples.

Williams, L.M.; Bartholomay, R.C.; Campbell, L.J.

1998-10-01T23:59:59.000Z

190

On the use of 127Xe standards for the quality control of CTBTO noble gas stations and support laboratories  

Science Journals Connector (OSTI)

Abstract 127Xe has a longer half-life than 131mXe, it can be easily purely produced and it is present in the environment at very low level. For these reasons, 127Xe is supposed to be a convenient quality control radionuclide for remote noble gas stations of the International Monitoring System (IMS) network. As CEA/DAM has recently developed two new photon/electron setups for low-level detection of 131mXe, 133mXe, 133Xe and 135Xe, we took the opportunity to test these setups for the measurement of a 127Xe standard. The results and a detailed description of these measurements are presented in this paper. They illustrate the complexity of 127Xe decay, emitting simultaneously several ?, X-rays, conversion electrons and Auger electrons; this results in highly summated coincidence spectra. The measurements performed provide precise electron energy calibration of the setups. The count rate of electrons in coincidence with iodine K? X-rays was found to be surprisingly low, leading to the study of electron-gated photon spectrum. Finally, a comparison of three photon/electron coincidence spectra obtained with three different setups is given. The use of 127Xe as a standard for energy calibration of IMS noble gas station is possible, but it appears to be quite complicated for efficiency check of noble gas station equipped with ?/? detectors.

A. Cagniant; G. Le Petit; B. Nadalut; P. Gross; H. Richard-Bressand; J.-P. Fontaine; G. Douysset

2014-01-01T23:59:59.000Z

191

Forrestal Garage Parking Procedures, Revised August 12, 2010  

Broader source: Energy.gov [DOE]

Forrestal Garage Parking Procedures - The Forrestal Facility Parking Guide was created to define policies and procedures governing the assignment, use, and management of parking spaces controlled...

192

Ex H (Rev. 7) Exhibit H Quality Assurance Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ex H (Rev. 7) Exhibit H Quality Assurance Requirements Ex H (Rev. 7) Exhibit H Quality Assurance Requirements Dated: 3-25-13 Subcontract No. 241314 Page 1 of 6 EXHIBIT "H" QUALITY ASSURANCE REQUIREMENTS TABLE OF CONTENTS QC Title Page QC-02 DESIGN/CHANGE CONTROL FOR SUBCONTRACTOR PROVIDED DESIGN (May 2008) . 2 QC-06 CERTIFICATE OF CONFORMANCE (Standard) (May 2012) .................................................. 2 QC-07 MANUFACTURING, INSPECTION AND TEST PROCEDURES (Jun 2011) ........................... 2 QC-08 INSPECTION, EXAMINATION, AND TEST REPORTS (Sept 2011) ....................................... 2 QC-11 ENGINEERING DRAWINGS (Sept 2011) ................................................................................. 2

193

Plutonium Immobilization Project, Project Office Quality Assurance Program Description Revision 1  

SciTech Connect (OSTI)

''The quality assurance activity involves the establishment and implementation of the Quality Assurance Program and the development of a Quality Assurance Plan and Procedures. Quality Assurance provides the plans, procedures and controls that are required for repository acceptance and the immobilization plant licensing and design activities.'' The Plutonium Immobilization Project (PIP) has a policy that all development, testing and operational activities be planned and performed in accordance with its customer's needs and expectations, and with a commitment to excellence and continuous improvement. The Immobilization Development and Testing (D&T) Quality Assurance Program establishes implementation requirements which, when completed, will ensure that the program development and test activities conform to the appropriate QA requirements. In order for the program to be effective, a designated quality lead must be in place at the Project Office and each participating site.

Kan, T.

1998-04-30T23:59:59.000Z

194

NSF ITR Project General Notes on Trypsin Test Procedure  

E-Print Network [OSTI]

NSF ITR Project Fall 2004 General Notes on Trypsin Test Procedure: Automated performance procedure the assay still work"?) Calculation of the Z' ­ Factor (quality criteria) Manual performance procedure: (Uses/purpose of procedure: Setup a new assay. Use as basis for comparison with automated version

Kaber, David B.

195

Texas Surface Water Quality Standards  

E-Print Network [OSTI]

1 Texas Surface Water Quality Standards 30 TAC Chapter 307 Lori Hamilton Water Quality Standards of the water quality standards for a water body will be conducted Types of UAAs Aquatic Life Use (ALU) UAAs 2 procedures in conjunction with Standards revision Before Conducting a UAA Coordinate with your TCEQ project

196

Buffer Tank Design for Acceptable Control Performance  

E-Print Network [OSTI]

Buffer Tank Design for Acceptable Control Performance Audun Faanes and Sigurd Skogestad for the design of buffer tanks. We consider mainly the case where the objective of the buffer tank is to dampen- trol system. We consider separately design procedures for (I) mixing tanks to dampen quality

Skogestad, Sigurd

197

Delegation Procedures - DOE Directives, Delegations, and Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Delegation Procedures Text Delegation Procedures Delegation Template Text Redelegation Procedures Redelegation Template Delegation Procedures Redelegation Procedures...

198

Chemical analysis quality assurance at the ICPP  

SciTech Connect (OSTI)

This document discusses the chemical analysis quality assurance program at the ICPP which involves records management, analytical methods quality control, analysis procedures and training and qualification. Since 1979, the major portion of the quality assurance program has been implemented on a central analytical computer system. The individual features provided by the system are storage, retrieval, and search capabilities over all general request and sample analysis information, automatic method selection for all process streams, automation of all method calculations, automatic assignment of bias and precision estimates at all analysis levels, with-method-use requalification, untrained or unqualified analyst method lockout, statistical testing of all process stream results for replicate agreement, automatic testing of process results against pre- established operating, safety, or failure limits at varying confidence levels, and automatic transfer and report of all analysis data plus all statistical testing to the Production Department.

Hand, R.L.

1990-01-01T23:59:59.000Z

199

Chemical analysis quality assurance at the ICPP  

SciTech Connect (OSTI)

This document discusses the chemical analysis quality assurance program at the ICPP which involves records management, analytical methods quality control, analysis procedures and training and qualification. Since 1979, the major portion of the quality assurance program has been implemented on a central analytical computer system. The individual features provided by the system are storage, retrieval, and search capabilities over all general request and sample analysis information, automatic method selection for all process streams, automation of all method calculations, automatic assignment of bias and precision estimates at all analysis levels, with-method-use requalification, untrained or unqualified analyst method lockout, statistical testing of all process stream results for replicate agreement, automatic testing of process results against pre- established operating, safety, or failure limits at varying confidence levels, and automatic transfer and report of all analysis data plus all statistical testing to the Production Department.

Hand, R.L.

1990-12-31T23:59:59.000Z

200

222-S Laboratory Quality Assurance Plan. Revision 1  

SciTech Connect (OSTI)

This Quality Assurance Plan provides,quality assurance (QA) guidance, regulatory QA requirements (e.g., 10 CFR 830.120), and quality control (QC) specifications for analytical service. This document follows the U.S Department of Energy (DOE) issued Hanford Analytical Services Quality Assurance Plan (HASQAP). In addition, this document meets the objectives of the Quality Assurance Program provided in the WHC-CM-4-2, Section 2.1. Quality assurance elements required in the Guidelines and Specifications for Preparing Quality Assurance Program Plans (QAMS-004) and Interim Guidelines and Specifications for Preparing Quality Assurance Project Plans (QAMS-005) from the US Environmental Protection Agency (EPA) are covered throughout this document. A quality assurance index is provided in the Appendix A. This document also provides and/or identifies the procedural information that governs laboratory operations. The personnel of the 222-S Laboratory and the Standards Laboratory including managers, analysts, QA/QC staff, auditors, and support staff shall use this document as guidance and instructions for their operational and quality assurance activities. Other organizations that conduct activities described in this document for the 222-S Laboratory shall follow this QA/QC document.

Meznarich, H.K.

1995-07-31T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Microbiological, Geochemical and Hydrologic Processes Controlling Uranium Mobility: An Integrated Field-Scale Subsurface Research Challenge Site at Rifle, Colorado, Quality Assurance Project Plan  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) is cleaning up and/or monitoring large, dilute plumes contaminated by metals, such as uranium and chromium, whose mobility and solubility change with redox status. Field-scale experiments with acetate as the electron donor have stimulated metal-reducing bacteria to effectively remove uranium [U(VI)] from groundwater at the Uranium Mill Tailings Site in Rifle, Colorado. The Pacific Northwest National Laboratory and a multidisciplinary team of national laboratory and academic collaborators has embarked on a research proposed for the Rifle site, the object of which is to gain a comprehensive and mechanistic understanding of the microbial factors and associated geochemistry controlling uranium mobility so that DOE can confidently remediate uranium plumes as well as support stewardship of uranium-contaminated sites. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by the Rifle Integrated Field-Scale Subsurface Research Challenge Project.

Fix, N. J.

2008-01-07T23:59:59.000Z

202

Analytical laboratory quality audits  

SciTech Connect (OSTI)

Analytical Laboratory Quality Audits are designed to improve laboratory performance. The success of the audit, as for many activities, is based on adequate preparation, precise performance, well documented and insightful reporting, and productive follow-up. Adequate preparation starts with definition of the purpose, scope, and authority for the audit and the primary standards against which the laboratory quality program will be tested. The scope and technical processes involved lead to determining the needed audit team resources. Contact is made with the auditee and a formal audit plan is developed, approved and sent to the auditee laboratory management. Review of the auditee's quality manual, key procedures and historical information during preparation leads to better checklist development and more efficient and effective use of the limited time for data gathering during the audit itself. The audit begins with the opening meeting that sets the stage for the interactions between the audit team and the laboratory staff. Arrangements are worked out for the necessary interviews and examination of processes and records. The information developed during the audit is recorded on the checklists. Laboratory management is kept informed of issues during the audit so there are no surprises at the closing meeting. The audit report documents whether the management control systems are effective. In addition to findings of nonconformance, positive reinforcement of exemplary practices provides balance and fairness. Audit closure begins with receipt and evaluation of proposed corrective actions from the nonconformances identified in the audit report. After corrective actions are accepted, their implementation is verified. Upon closure of the corrective actions, the audit is officially closed.

Kelley, William D.

2001-06-11T23:59:59.000Z

203

Council on Environmental Quality - Regulations for Implementing...  

Open Energy Info (EERE)

LibraryAdd to library Legal Document- StatuteStatute: Council on Environmental Quality - Regulations for Implementing the Procedural Provisions of the NEPALegal Abstract...

204

Quality engineering as a profession.  

SciTech Connect (OSTI)

Over the course of time, the profession of quality engineering has witnessed significant change, from its original emphasis on quality control and inspection to a more contemporary focus on upholding quality processes throughout the organization and its product realization activities. This paper describes the profession of quality engineering, exploring how today's quality engineers and quality professionals are certified individuals committed to upholding quality processes and principles while working with different dimensions of product development. It also discusses the future of the quality engineering profession and the future of the quality movement as a whole.

Kolb, Rachel R.; Hoover, Marcey L.

2012-12-01T23:59:59.000Z

205

Standard guide for establishing a quality assurance program for uranium conversion facilities  

E-Print Network [OSTI]

1.1 This guide provides guidance and recommended practices for establishing a comprehensive quality assurance program for uranium conversion facilities. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate health and safety practices and determine the applicability of regulatory limitations prior to use. 1.3 The basic elements of a quality assurance program appear in the following order: FUNCTION SECTION Organization 5 Quality Assurance Program 6 Design Control 7 Instructions, Procedures & Drawings 8 Document Control 9 Procurement 10 Identification and Traceability 11 Processes 12 Inspection 13 Control of Measuring and Test Equipment 14 Handling, Storage and Shipping 15 Inspection, Test and Operating Status 16 Control of Nonconforming Items 17 Corrective Actions 18 Quality Assurance Records 19 Audits 20 TABLE 1 NQA-1 Basic Requirements Relat...

American Society for Testing and Materials. Philadelphia

2004-01-01T23:59:59.000Z

206

Student Policies & Procedures  

E-Print Network [OSTI]

Student Policies & Procedures summer.uci.edu #12;STUDENT POLICIES AND PROCEDURES Rev. 04/2014 1 ...................................................................................... 9 #12;STUDENT POLICIES AND PROCEDURES Rev. 04/2014 2 Who Summer Session Serves Current UCI Students

Barrett, Jeffrey A.

207

Contract and Procedure  

E-Print Network [OSTI]

This paper examines both the theoretical underpinnings and empirical picture of procedural contracts. Procedural contracts may be understood as contracts in which parties regulate not merely their commercial relations but also the procedures...

Drahozal, Christopher R.

2011-01-01T23:59:59.000Z

208

NEWNHAM COLLEGE Procedures for solving problems (complaints from students)  

E-Print Network [OSTI]

NEWNHAM COLLEGE CAMBRIDGE Procedures for solving problems (complaints from students) Overview What is a Complaints Procedure For? Newnham College is committed to a high quality of educational and other provision individual or general matters. A complaints procedure provides a background safeguard for students

Lasenby, Joan

209

INDOOR AIR QUALITY MEASUREMENTS IN ENERGY EFFICIENT BUILDINGS  

E-Print Network [OSTI]

of Engineering, Coordinating Committee of Air QualityStandards: Air Quality and Automobile Emission Control, Vol.of ilitrogen Dioxide Air Quality Standards. Paper tlo. 76-

Hollowell, C.D.

2011-01-01T23:59:59.000Z

210

IDEAReauthorized Statute PROCEDURAL SAFEGUARDS  

E-Print Network [OSTI]

IDEA­Reauthorized Statute PROCEDURAL SAFEGUARDS: SURROGATES, NOTICE AND CONSENT (See also Changes addresses only the changes to IDEA provisions regarding procedural safeguards related to notice to parents the provision of procedural safeguards notices to parents. A copy of the procedural safeguards available

211

Writer`s guide for technical procedures  

SciTech Connect (OSTI)

A primary objective of operations conducted in the US Department of Energy (DOE) complex is safety. Procedures are a critical element of maintaining a safety envelope to ensure safe facility operation. This DOE Writer`s Guide for Technical Procedures addresses the content, format, and style of technical procedures that prescribe production, operation of equipment and facilities, and maintenance activities. The DOE Writer`s Guide for Management Control Procedures and DOE Writer`s Guide for Emergency and Alarm Response Procedures are being developed to assist writers in developing nontechnical procedures. DOE is providing this guide to assist writers across the DOE complex in producing accurate, complete, and usable procedures that promote safe and efficient operations that comply with DOE orders, including DOE Order 5480.19, Conduct of Operations for DOE Facilities, and 5480.6, Safety of Department of Energy-Owned Nuclear Reactors.

NONE

1998-12-01T23:59:59.000Z

212

HUMAN RELIABILITY ANALYSIS FOR COMPUTERIZED PROCEDURES  

SciTech Connect (OSTI)

This paper provides a characterization of human reliability analysis (HRA) issues for computerized procedures in nuclear power plant control rooms. It is beyond the scope of this paper to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper provides a review of HRA as applied to traditional paper-based procedures, followed by a discussion of what specific factors should additionally be considered in HRAs for computerized procedures. Performance shaping factors and failure modes unique to computerized procedures are highlighted. Since there is no definitive guide to HRA for paper-based procedures, this paper also serves to clarify the existing guidance on paper-based procedures before delving into the unique aspects of computerized procedures.

Ronald L. Boring; David I. Gertman; Katya Le Blanc

2011-09-01T23:59:59.000Z

213

Quality Assurance: Quality Policy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Policy Policy It is the policy of the Department of Energy to establish quality requirements to ensure that risks and environmental impacts are minimized and that safety, reliability, and performance are maximized through the application of effective management systems commensurate with the risks posed by the facility or activity and its work. The Department implements this policy through the QA Order and the QA rule directives to ensure quality assurance requirements are clearly specified for the broad spectrum of work performed by DOE and its contractors. Objective The objective of the QA requirements are to establish an effective management system (i.e., quality assurance programs) using the performance requirements coupled technical standards where appropriate that ensure:

214

Sampling and Analysis Procedures for Gas, Condensate, Brine, and Solids: Pleasant Bayou Well Test, 1988-Present  

SciTech Connect (OSTI)

This section covers analyses performed on gas. Chemical analyses can only be related to well performance if the quantity of the various fluids are known. The IGT on-line data computer system measures the flowrate, the pressures, and the temperatures every 10 seconds. These values are automatically recorded over operator selected intervals both on magnetic media and on paper. This allows review of samples versus operating conditions. This paper covers analyses performed on gas, including: An approximate sampling schedule during flow tests; On-site sample handling and storage of gas samples; Addresses of laboratories that perform off site analyses; Sample shipping instructions; Data archiving; and Quality Control/Quality Assurance. It is expected that the above procedures will change as the flow test progresses, but deviations from the written procedures should be approved by C. Hayden of IGT and noted on the results of the analysis.

Hayden, Chris

1988-01-01T23:59:59.000Z

215

Using internet GIS technology for early warning, response and controlling the quality of the public health sector  

Science Journals Connector (OSTI)

Recent EU and Greek Government legislation highlights the need for the modernisation of the public health management system and the improvement of the overall health of EU citizens. In addition, the effusion of epidemics even in developed countries makes the need for the enhancement of public health services imperative. In order to best confront the above-described challenges, the National Technical University of Athens, in cooperation with the Greek Ministry of Health and Welfare and the European Commission (EC), designed and developed an integrated public health information network, named GEPIMI (Integrated Geographical System for EPIdemiological and other Medical Information), in the framework of a three-year pilot project. This pilot project, funded by Greek Ministry of Health and Welfare and the EC supported the Programme INTERREG II to establish an advanced and integrated web-based information system that can process and move information in real time, allowing public health authorities to monitor events at hundreds or thousands of public health facilities at once. The system is established among hospitals, primary healthcare authorities and health agents in Greece, Bulgaria, Albania, Fyrom, and Turkey. The project aims at demonstrating the best practices, prospects, applications and high potential of Telematics Healthcare Networks in Europe, with a view to promoting cooperation and interconnection between European communities in the field of Telematics Healthcare Applications. The GEPIMI System, implemented via an innovative web based system, constitutes a replication of a highly effective mechanism. It incorporates state-of-the-art technologies such as Geographic Information Systems (G.I.S.), web based databases, GPS, and Smart Card Technology and supports a variety of health-related web applications including early warning and response of epidemics, remote management of medical records, seamless healthcare coverage, comprehensive statistical analysis of data, decision-making procedures, inter-communication between international scientific fora and other.

Dimitrios Ptochos; Dimitrios Panopoulos; Kostas Metaxiotis; Dimitrios Askounis; John Psarras

2004-01-01T23:59:59.000Z

216

E-Print Network 3.0 - analytical quality assurance Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

for NRDA followed standard operating procedure (SOP), water sampling plans, Summary: procedures, and NOAA's Analytical Quality Assurance Project Plan (QAPP). Samples were sent...

217

HEALTH AND SAFETY PROCEDURES -Major Projects  

E-Print Network [OSTI]

HEALTH AND SAFETY PROCEDURES - Major Projects HEALTH & SAFETY UNIT SPRING 2006 #12;CONTENTS of this document is to provide the University with a summary of the principle activities in construction projects the reliance on physical controls and use of personnel protective equipment. The procedures that consider

218

Water Quality (Oklahoma)  

Broader source: Energy.gov [DOE]

The Water Quality Act establishes cumulative remedies to prevent, abate and control the pollution of the waters of the state. The act establishes responsibilities of the Oklahoma Department of...

219

Regulations and Procedures Manual  

E-Print Network [OSTI]

Quality Assurance and Conduct of Operations requirements forassurance and conduct- of-operations principles. These

Young, Lydia J.

2014-01-01T23:59:59.000Z

220

Verification and Monitoring: Requirements and Procedures  

Science Journals Connector (OSTI)

When a cleanroom is first installed or any significant changes ... and control. Many of the procedures for cleanroom monitoring are described in IES RP-006,...Recommended Practice for Testing Clean Ro...

Alvin Lieberman

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Project 1640 Palomar Procedures  

E-Print Network [OSTI]

Project 1640 Palomar Procedures Version 0.1 7/7/08 2:11:08 PM #12;2 Project 1640 Design and Operations Table of Contents Project 1640..................................................................................................................... 1 Palomar Procedures

222

Federal Agency NEPA Procedures  

Broader source: Energy.gov [DOE]

Each Federal agency is required to develop NEPA procedures that supplement the CEQ Regulations. Developed in consultation with CEQ, Federal agency NEPA procedures must meet the standards in the CEQ...

223

Standard guide for establishing a quality assurance program for analytical chemistry laboratories within the nuclear industry  

E-Print Network [OSTI]

1.1 This guide covers the establishment of a quality assurance (QA) program for analytical chemistry laboratories within the nuclear industry. Reference to key elements of ANSI/ISO/ASQC Q9001, Quality Systems, provides guidance to the functional aspects of analytical laboratory operation. When implemented as recommended, the practices presented in this guide will provide a comprehensive QA program for the laboratory. The practices are grouped by functions, which constitute the basic elements of a laboratory QA program. 1.2 The essential, basic elements of a laboratory QA program appear in the following order: Section Organization 5 Quality Assurance Program 6 Training and Qualification 7 Procedures 8 Laboratory Records 9 Control of Records 10 Control of Procurement 11 Control of Measuring Equipment and Materials 12 Control of Measurements 13 Deficiencies and Corrective Actions 14

American Society for Testing and Materials. Philadelphia

2006-01-01T23:59:59.000Z

224

Users manual for SERI QC software assessing the quality of solar radiation data  

SciTech Connect (OSTI)

This manual describes the procedures and software for assessing the quality of solar radiation data. This does not constitute quality control because quality control must take place during the preparations for data collection (selection, calibration, and installation of instruments), during the measurement process, and during the transmission (if any) and recording of the numerical values. Once the data are recorded, only quality assessment can be performed. If quality assessment is performed in real time or soon after the measurement process is completed, it can provide input to control the quality of future measurements. Furthermore, quality assessment can be used for quality control if data judged to be bad are deleted and/or modified. We do not subscribe to these actions because the deletion or modification of data destroys information that might be useful to the user. For example, if an instrument has gone through a gradual failure and all of the data that fail quality assessment criteria are deleted or modified, the user of the data may not be able to detect what was happening and will not question the accuracy of other data collected before the instrument completely failed. Therefore, the SERI QC procedures and software do not delete or modify data. Instead, flags are set to inform the user of any departure of the data from expected values. These flags indicate the magnitude and direction of such departures. For the flags to communicate as much information as possible, this manual attempts to identify and explain the probable causes of various flags. However, we cannot overemphasize the following: Flags only indicate that data do or do not fall within expected ranges. This does not mean that the data that the data are or are not valid.

none,

1993-12-01T23:59:59.000Z

225

Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor  

DOE Patents [OSTI]

A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

Van Berkel, Gary J. (Clinton, TN); Kertesz, Vilmos (Knoxville, TN)

2012-02-21T23:59:59.000Z

226

Focus groups: impact of quality and process capability factors on the silicon wafer slicing process  

Science Journals Connector (OSTI)

Silicon wafer slicing is a highly complex manufacturing process, complicating efforts to monitor individual product type process stability and quality control effectively. Specifically, silicon wafer slicing involves multiple quality characteristics that occur synchronously. However, quantitative methods, such as process capability indices (PCIs) and statistical process control (SPC) charts, for monitoring slicing problems are limited. Therefore, this study presents a focus group procedure that explores engineering knowledge and expertise. Organisations can use focus groups to create knowledge of stable processes, optimal settings and quality control. Interactive discussions indicate that focus groups can improve productivity and decision making effectiveness either by accelerating the decision making or by increasing decision quality. Moreover, the proposed procedure enables an engineer to rapidly adjust a manufacturing system to eliminate problems related to slicing process instability phenomena and improve slicing quality and process capability. Finally, the SPC chart and the exponential weighted moving average (EWMA) control chart are presented to demonstrate and verify the feasibility and effectiveness of the proposed methods.

Chin-Tsai Lin; Che-Wei Chang; Chie-Bein Chen

2004-01-01T23:59:59.000Z

227

EV America Skid Test Procedure  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

6 6 Revision 2 Effective October 1, 2007 Braking Test Prepared by Electric Transportation Applications Prepared by: _______________________________ Date: _________ Roberta Brayer Approved by: _________________________________________________ Date: _______________ Donald Karner Procedure ETA-HTP06 Revision 2 i TABLE OF CONTENTS 1. Objectives 1 2. Purpose 1 3. Documentation 1 4. Initial Conditions and Prerequisites 1 5. Testing Activity Requirements 3 5.3 Dry Controlled Test 4 6. Glossary 5 7. References 7 Appendices Appendix A - Handling Pad Test Data Sheet 8

228

Safeguards management inspection procedures  

SciTech Connect (OSTI)

The objective of this inspection module is to independently assess the contributions of licensee management to overall safeguards systems performance. The inspector accomplishes this objective by comparing the licensee's safeguards management to both the 10 CFR, parts 70 and 73, requirements and to generally accepted management practices. The vehicle by which this comparison is to be made consists of assessment questions and key issues which point the inspector to areas of primary concern to the NRC and which raise additional issues for the purpose of exposing management ineffectiveness. Further insight into management effectiveness is obtained through those assessment questions specifically directed toward the licensee's safeguards system performance. If the quality of the safeguards is poor, then the inspector should strongly suspect that management's role is ineffective and should attempt to determine management's influence (or lack thereof) on the underlying safeguards deficiencies. (The converse is not necessarily true, however.) The assessment questions in essence provide an opportunity for the inspector to identify, to single out, and to probe further, questionable management practices. Specific issues, circumstances, and concerns which point to questionable or inappropriate practices should be explicitly identified and referenced against the CFR and the assessment questions. The inspection report should also explain why the inspector feels certain management practices are poor, counter to the CFR, and/or point to ineffecive management. Concurrent with documenting the inspection results, the inspector should provide recommendations for alleviating observed management practices that are detrimental to effective safeguards. The recommendations could include: specific changes in the practices of the licensee, followup procedures on the part of NRC, and proposed license changes.

Barth, M.J.; Dunn, D.R.

1984-08-01T23:59:59.000Z

229

U.A.C. R317-9: Administrative Procedures | Open Energy Information  

Open Energy Info (EERE)

RegulationRegulation: U.A.C. R317-9: Administrative ProceduresLegal Abstract This section states that administrative procedures under the Utah Water Quality Act are governed by...

230

The evaluation of two extraction procedures for the recovery of organic chemicals from spiked soils  

E-Print Network [OSTI]

procedure to desorb and remove contaminants from a sample matrix prior to analysis. The recovery efficiency of an extraction procedure will indeed affect the quality of analytical data and may influence waste site assessments. The objective of this study...

Huebner, Henry Joseph

1993-01-01T23:59:59.000Z

231

Regulations and Procedures Manual  

E-Print Network [OSTI]

Quality Assurance and Conduct of Operations requirements forquality assurance/conduct of operations performanceassurance and conduct of operations principles. These

Young, Lydia

2014-01-01T23:59:59.000Z

232

Reporting Cooperating Agencies in Implementing the Procedural Requirements  

Broader source: Energy.gov (indexed) [DOE]

Reporting Cooperating Agencies in Implementing the Procedural Reporting Cooperating Agencies in Implementing the Procedural Requirements of the National Environmental Policy Act Reporting Cooperating Agencies in Implementing the Procedural Requirements of the National Environmental Policy Act The purpose of this Council on Environmental Quality Memorandum is to establish a revised report to ensure that all Federal agencies are consistently reporting designation of Federal and non-federal cooperating agencies in the preparation of analyses and documentation required by the National Environmental Policy Act (NEPA). REPORTING COOPERATING AGENCIES IN IMPLEMENTING THE PROCEDURAL REQUIREMENTS OF THE NATIONAL ENVIRONMENTAL POLICY ACT More Documents & Publications Cooperating Agencies in Implementing the Procedural Requirements of the

233

Reporting Cooperating Agencies in Implementing the Procedural Requirements  

Broader source: Energy.gov (indexed) [DOE]

Reporting Cooperating Agencies in Implementing the Procedural Reporting Cooperating Agencies in Implementing the Procedural Requirements of the National Environmental Policy Act Reporting Cooperating Agencies in Implementing the Procedural Requirements of the National Environmental Policy Act The purpose of this Council on Environmental Quality Memorandum is to establish a revised report to ensure that all Federal agencies are consistently reporting designation of Federal and non-federal cooperating agencies in the preparation of analyses and documentation required by the National Environmental Policy Act (NEPA). REPORTING COOPERATING AGENCIES IN IMPLEMENTING THE PROCEDURAL REQUIREMENTS OF THE NATIONAL ENVIRONMENTAL POLICY ACT More Documents & Publications Cooperating Agencies in Implementing the Procedural Requirements of the

234

Cable Measuring Engine Operation Procedures  

E-Print Network [OSTI]

MEASURING ENGINE OPERATION PROCEDURES LBNL-40565 SC-MAG-597MEASURING ENGINE OPERATION PROCEDURES INDEX IN T ROD U C TCALIBRATION PROCEDURE . .

Authors, Various

2011-01-01T23:59:59.000Z

235

E-Print Network 3.0 - air quality handbook Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of Engineering, Solar Energy Program Collection: Renewable Energy ; Engineering 13 Air Quality: Asbestos Notification Procedure Department: Chemical and General Safety...

236

Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System - 1997 Notice of Violation Consent Order  

SciTech Connect (OSTI)

This Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA- 731 Caustic and Acid Storage Tank System is one of two documents that comprise the Sampling and Analysis Plan for the HWMA/RCRA closure certification of the TRA-731 caustic and acid storage tank system at the Idaho National Engineering and Environmental Laboratory. This plan, which provides information about the project description, project organization, and quality assurance and quality control procedures, is to be used in conjunction with the Field Sampling Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System. This Quality Assurance Project Plan specifies the procedures for obtaining the data of known quality required by the closure activities for the TRA-731 caustic and acid storage tank system.

Evans, S.K.

2002-01-31T23:59:59.000Z

237

Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System - 1997 Notice of Violation Consent Order  

SciTech Connect (OSTI)

This Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System is one of two documents that comprise the Sampling and Analysis Plan for the HWMA/RCRA closure certification of the TRA-731 caustic and acid storage tank system at the Idaho National Engineering and Environmental Laboratory. This plan, which provides information about the project description, project organization, and quality assurance and quality control procedures, is to be used in conjunction with the Field Sampling Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System. This Quality Assurance Project Plan specifies the procedures for obtaining the data of known quality required by the closure activities for the TRA-731 caustic and acid storage tank system.

Evans, Susan Kay; Orchard, B. J.

2002-01-01T23:59:59.000Z

238

Systems Design and Applications Branch (SDAB) Hayden Menzel ( Prins) Key Advanced Satellite Products Branch (ASPB) Timothy J. Schmit validating and improving GOES (Imager & Sounder) products -GOES calibration and quality control  

E-Print Network [OSTI]

. White} {Richard A. Frank} {John V. Byrne} {Anthony J. Calio} {William Evans} {John A. Knauss} {D. James calibration and quality control - developing prototypes for future GOES products - GOES-R - promoting future of Research and Applications (ORA) {Harold Yates} { P. K. Rao} {James F. W. Purdom, Jr } {Marie C. Colton

Kuligowski, Bob

239

Geiger M., Diabat L., Mnard L., Wald L., 2002. A web service for controlling the quality of measurements of global solar irradiation. Solar Energy, Vol. 73, No 6, pp. 475-480  

E-Print Network [OSTI]

sensitive sensors measure the downward solar radiation flux on a horizontal surface during a given time of measurements of global solar irradiation. Solar Energy, Vol. 73, No 6, pp. 475-480 Copyright Ecole des Mines de Paris -Armines - UFAE 1 A WEB SERVICE FOR CONTROLLING THE QUALITY OF MEASUREMENTS OF GLOBAL SOLAR

Paris-Sud XI, Université de

240

Diesel fuel qualities  

SciTech Connect (OSTI)

As a result of rising fuel costs, many ship operators are turning to less expensive, heavier grade fuels for their diesel engines. Use of these lower quality fuels without adequate preparation can cause increased engine wear and damage to fuel systems. The oil properties which affect pretreatment and cleaning requirements, specifications that should be used when purchasing these fuels, and procedures for confirming that bought fuels meet purchase specifications are discussed. (LCL)

Blenkey, N.

1981-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Optimization Online - A Factorization with Update Procedures for a ...  

E-Print Network [OSTI]

Nov 11, 2009 ... A Factorization with Update Procedures for a KKT Matrix Arising in Direct Optimal Control. Christian Kirches (christian.kirches ***at*** ...

Christian Kirches

2009-11-11T23:59:59.000Z

242

Policy and Procedures for the Review of Federal Actions Impacting the Environment  

Broader source: Energy.gov [DOE]

This manual establishes polices and procedures for carrying out the EPA's responsibilities to review and comment on Federal actions affecting the quality of the environment. 

243

Policy and Procedures for the Review of Federal Actions Impacting the Environment  

Broader source: Energy.gov [DOE]

This manual establishes policies and procedures for carrying out the Environmental Protection Agency's responsibilities to review and comment on Federal actions affecting the quality of the environment.

244

ARM - Publications Procedures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

govPublicationsPublications Procedures Page Contents Types of ARM Publications Process for Publishing Planning Documents Science Reports Conference Documents Public Information...

245

TRANSPARENCY RECYCLING PROGRAM PROCEDURES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

used overhead transparencies RECYCLE them for REUSE. It's Easy Follow these simple procedures: 1.) COLLECT used transparencies to be recycled. 2.) SEPARATE the transparencies...

246

PROCEDURES FOR ARC PROJECTS  

E-Print Network [OSTI]

PROCEDURES FOR ARC PROJECTS Revised - May 2013 Agricultural Research Center Washington State University #12;Table of Contents THE PROJECT SYSTEM, AN INTRODUCTION................................................................................. 5 DEVELOPING AN ARC PROJECT

Collins, Gary S.

247

Teaching Physician Guidelines for Surgical Procedures Minor Surgical Procedures  

E-Print Network [OSTI]

Teaching Physician Guidelines for Surgical Procedures Minor Surgical Procedures: § Procedures, the teaching physician must be present for the entire procedure § Teaching physician or resident may document the teaching physician's presence for the entire procedure High Risk and Complex Surgical Procedures

Goldman, Steven A.

248

Appropriateness Criteria and Elective Procedures — Total Joint Arthroplasty  

Science Journals Connector (OSTI)

...the importance of such criteria and have already started developing them as guidelines for other orthopedic procedures. Second, accountable care organizations and other institutions pursuing similar health care delivery models are becoming influential, and as they move away from procedure-based payments... The implementation of appropriateness criteria that help to identify the patients likely to benefit most from a given procedure could help to combat increasing health care costs while enhancing access and quality. Total joint arthroplasty offers a prime example.

Ghomrawi H.M.K.Schackman B.R.Mushlin A.I.

2012-12-27T23:59:59.000Z

249

EERE Quality Control Workshop Agenda  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Consultant, formerly of GE Primestar Panelist: David Gotthold, PNNL Panelist: Ron Sinton, Sinton Instruments 12:00 Lunch 1:00 Breakout 1: QC challenges by technology area 1:50...

250

Information Incident Response Procedure  

E-Print Network [OSTI]

Information Incident Response Procedure Authority The Information Incident Response Procedure (IIRP) is authorized under the UWM Information Security Policy S59; section III-D (http://www4.uwm Information Security Office, and UWM Internal Audit. This document will be reviewed and updated annually

Saldin, Dilano

251

Text Redelegation Procedures - DOE Directives, Delegations, and...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Text Redelegation Procedures by Website Administrator Delegation Procedures Redelegation Procedures Redelegation Procedures for Functional Area Managers This page contains...

252

Procedures and Instructions | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Records Management Procedures and Instructions Procedures and Instructions Records Management Processes Procedure for Conducting a Records Inventory (PDF) Procedure for...

253

Redelegation Procedures - DOE Directives, Delegations, and Requirement...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Redelegation Procedures by Website Administrator Text version available here. Delegation Procedures Re-Delegation Procedures Document Actions Redelegation Procedures Redelegating...

254

Well control procedures for extended reach wells  

E-Print Network [OSTI]

been found to be critical to the success of ERD are torque and drag, drillstring design, wellbore stability, hole cleaning, casing design, directional drilling optimization, drilling dynamics and rig sizing.4 Other technologies of vital importance... are the use of rotary steerable systems (RSS) together with measurement while drilling (MWD) and logging while drilling (LWD) to geosteer the well into the geological target.5 Many of the wells drilled at Wytch Farm would not have been possible to drill...

Gjorv, Bjorn

2004-09-30T23:59:59.000Z

255

NEPA Implementation Procedures; Appendices I, II, and III  

Broader source: Energy.gov (indexed) [DOE]

_ _ _ _ _ _ _ _ ~ - Friday December 21, 1984 DOE Note: Some contact information may be outdated. Refer to the current edition of Directory o f Potential Stakeholders for Department of Energy Actions under the National Environmental Policy Act (updated annually). Part 11 Council on Environmental Quality 40 CFR Ch. V National Environmental Policy Act (NEPA) Implementation Procedures; Appendices I, II, and 111; Final Rule 49750 Federal Register I Vol. 49, No. 247 / Friday, December 21, 1984 I Rules and Regulations COUNCIL ON ENVIRONMENTAL QUALITY 40 CFRCh. V National Envircnmental Policy Act (NEPA) Implementation Procedures; Appendices I, I!, and lli AGENCY: Council on Environmental Quality, Executive Office of the President. ACTION: Appendices to regulations,

256

Pilot Implementation of a Field Study Design to Evaluate the Impact of Source Control Measures on Indoor Air Quality in High Performance Homes  

SciTech Connect (OSTI)

To improve the indoor air quality in new, high performance homes, a variety of standards and rating programs have been introduced to identify building materials that are designed to have lower emission rates of key contaminants of concern and a number of building materials are being introduced that are certified to these standards. For example, the U.S. Department of Energy (DOE) Zero Energy Ready Home program requires certification under the U.S. Environmental Protection Agency (EPA) Indoor airPLUS (IaP) label, which requires the use of PS1 or PS2 certified plywood and OSB; low-formaldehyde emitting wood products; low- or no-VOC paints and coatings as certified by Green Seal Standard GS-11, GreenGuard, SCS Indoor Advantage Gold Standard, MPI Green Performance Standard, or another third party rating program; and Green Label-certified carpet and carpet cushions. However, little is known regarding the efficacy of the IAP requirements in measurably reducing contaminant exposures in homes. The goal of this project is to develop a robust experimental approach and collect preliminary data to support the evaluation of indoor air quality (IAQ) measures linked to IAP-approved low-emitting materials and finishes in new residential homes. To this end, the research team of Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) developed a detailed experimental plan to measure IAQ constituents and other parameters, over time, in new homes constructed with materials compliant with IAP’s low-emitting material and ventilation requirements (i.e., section 6.1, 6.2, 6.3, and 7.2) and similar homes constructed to the state building code with conventional materials. The IAQ in IAP and conventional homes of similar age, location, and construction style is quantified as the differences in the speciated VOC and aldehyde concentrations, normalized to dilution rates. The experimental plan consists of methods to evaluate the difference between low-emitting and “conventional” materials as installed in newly constructed residential homes using both (1) highly controlled, short-term active samples to precisely characterize the building-related chemical emissions and building contents and (2) a week-long passive sample designed to capture the impact of occupant behavior and related activities on measured IAQ contaminant levels indoors. The combination of detailed short-term measurements with the home under controlled/consistent conditions during pre- and post-occupancy and the week-long passive sampling data provide the opportunity to begin to separate the different emission sources and help isolate and quantify variability in the monitored homes. Between April and August 2014, the research team performed pre-occupancy and post-occupancy sampling in one conventional home and two homes built with low-emitting materials that were generally consistent with EPA’s Indoor airPLUS guidelines. However, for a number of reasons, the full experimental plan was not implemented. The project was intended to continue for up to three years to asses long-term changes in IAQ but the project was limited to one calendar year. As a result, several of the primary research questions related to seasonal impacts and the long-term trends in IAQ could not be addressed. In addition, there were several unexpected issues related to recruiting, availability of home types, and difficulty coordinating with builders/realtors/homeowners. Several field monitoring issues also came up that provide “lessons learned” that led to improvements to the original monitoring plan. The project produced a good experimental plan that is expected to be be useful for future efforts collecting data to support answering these same or similar research questions.

Widder, Sarah H.; Chamness, Michele A.; Petersen, Joseph M.; Singer, Brett C.; Maddalena, Randy L.; Destaillats, Hugo

2014-10-20T23:59:59.000Z

257

SOPP-43, EM-23 Quality Assurance Oversight  

Broader source: Energy.gov [DOE]

Procedure to describe the process that will be utilized by the EM Office of Standards and Quality Assurance to guide its activities related to oversight and audit of the EM Field/site, project, and...

258

Xerostomia and quality of life after intensity-modulated radiotherapy vs. conventional radiotherapy for early-stage nasopharyngeal carcinoma: Initial report on a randomized controlled clinical trial  

SciTech Connect (OSTI)

Purpose: To compare directly the effect of intensity-modulated radiotherapy (IMRT) vs. conventional radiotherapy (CRT) on salivary flow and quality of life (QoL) in patients with early-stage nasopharyngeal carcinoma (NPC). Methods and Materials: Fifty-one patients with T2, N0/N1, M0 NPC took part in a randomized controlled clinical study and received IMRT or CRT. Stimulated whole (SWS) and parotid (SPS) saliva flow were measured and Medical Outcomes Short Form 36 (SF-36), European Organization for Research and Treatment of Cancer (EORTC) core quetionnaire, and EORTC head-and-neck module (QLQ-H and N35) were completed at baseline and 2, 6, and 12 months after radiotherapy. Results: Forty-six patients (88%) were in disease remission 12 months after radiotherapy. At 12 months postradiotherapy, 12 (50.0%) and 20 patients (83.3%) in the IMRT group had recovered at least 25% of preradiotherapy SWS and SPS flow respectively, compared with 1 (4.8%) and 2 patients (9.5%), respectively, in the CRT group. Global health scores showed continuous improvement in QoL after both treatments (p < 0.001). However, after 12 months subscale scores for role-physical, bodily pain, and physical function were significantly higher in the IMRT group, indicating a better condition (p < 0.05). Dry mouth and sticky saliva were problems in both groups 2 months after treatment. In the IMRT group, there was consistent improvement over time with xerostomia-related symptoms significantly less common than in the CRT group at 12 months postradiotherapy. Conclusions: IMRT was significantly better than CRT in terms of parotid sparing and improved QoL for early-stage disease. The findings support the case for assessment of health-related QoL in relation to head-and-neck cancer using a site-specific approach.

Pow, Edmond [Oral Rehabilitation, Faculty of Dentistry, University of Hong Kong, Hong Kong (China); Kwong, Dora [Department of Clinical Oncology, Faculty of Medicine, University of Hong Kong, Queen Mary Hospital, Hong Kong (China); McMillan, Anne S. [Oral Rehabilitation, Faculty of Dentistry, University of Hong Kong, Hong Kong (China)]. E-mail: annemcmillan@hku.hk; Wong, May [Periodontology and Dental Public Health, Faculty of Dentistry, University of Hong Kong, Hong Kong (China); Sham, Jonathan [Department of Clinical Oncology, Faculty of Medicine, University of Hong Kong, Queen Mary Hospital, Hong Kong (China); Leung, Lucullus [Department of Clinical Oncology, Faculty of Medicine, University of Hong Kong, Queen Mary Hospital, Hong Kong (China); Leung, W. Keung [Periodontology and Dental Public Health, Faculty of Dentistry, University of Hong Kong, Hong Kong (China)

2006-11-15T23:59:59.000Z

259

The dynamics, prediction, and control of wing rock in high–performance aircraft  

Science Journals Connector (OSTI)

...parameter and the simple procedure developed to predict...produce the undesirable handling quality of wing rock...accepted techniques often applied to stability and control...Air Force Institute of Technology (AU), Wright-Patterson...Air Force Institute of Technology (AU), Wright-Patterson...

1998-01-01T23:59:59.000Z

260

Procedures in Modules (1) Including all procedures within modules  

E-Print Network [OSTI]

Procedures in Modules (1) Including all procedures within modules works very well in almost all designing these if possible #12;Procedures in Modules (2) These are very much like internal procedures Works very well in almost all programs Everything accessible in the module can also be used in the procedure

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

E-Print Network 3.0 - air quality conformity Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: OKComponent Comments 200 Indoor Air Quality Forms Control sequence conforms to designspecifications? (describe changes... Indoor Air Quality...

262

Computerized operating procedures for shearing and dissolution of segments from LWBR (Light Water Breeder Reactor) fuel rods  

SciTech Connect (OSTI)

This report presents two detailed computerized operating procedures developed to assist and control the shearing and dissolution of irradiated fuel rods. The procedures were employed in the destructive analysis of end-of-life fuel rods from the Light Water Breeder Reactor (LWBR) that was designed by the Westinghouse Electric Corporation Bettis Atomic Power Laboratory. Seventeen entire fuel rods from the end-of-life core of the LWBR were sheared into 169 precisely characterized segments, and more than 150 of these segments were dissolved during execution of the LWBR Proof-of-Breeding (LWBR-POB) Analytical Support Project at Argonne National Laboratory. The procedures illustrate our approaches to process monitoring, data reduction, and quality assurance during the LWBR-POB work.

Osudar, J.; Deeken, P.G.; Graczyk, D.G.; Fagan, J.E.; Martino, F.J.; Parks, J.E.; Levitz, N.M.; Kessie, R.W.; Leddin, J.M.

1987-05-01T23:59:59.000Z

263

NFRC Procedures for Laminates  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Laminates Laminates Last update: 12/10/2013 07:29 PM NFRC now has a procedure for making laminates in Optics5 and importing those laminate constructions into WINDOW5 to be used in a whole product calculation. The information presented below is provided to help simulators with this process. Feel free to contact us at WINDOWHelp@lbl.gov with questions or comments. NFRC Laminate Procedure Laminate Procedures (approved by NFRC) (PDF file) Approved Interlayer List (IGDB 33.0) (PDF file) NFRC Laminate Procedure Training Powerpoint with Examples (This Powerpoint presentation was used in the NFRC web based training sessions in December 2006 and January 2007) PowerPoint Presentation (PPT file) PowerPoint Presentation (PDF file) Help and Troubleshooting Error Messages The table below contains common warnings and error messages that may appear in Optics5 when calculating a laminate. Some of the messages can be ignored, and some are significant, which is indicated in the table.

264

Quiz Policies and Procedures  

E-Print Network [OSTI]

Quiz Policies and Procedures. 1. Studying the lesson notes and completing most of the homework problems prior to class is the best way to prepare for a quiz. 2.

Bailey, Charlotte M

2014-08-19T23:59:59.000Z

265

PROCEDURE FOR PREPARING  

Broader source: Energy.gov (indexed) [DOE]

PROCEDURE FOR PREPARING PROCEDURE FOR PREPARING RECORDS INVENTORY AND DISPOSITION SCHEDULES (RIDS) Revision 1 November 1, 2007 Records Management Division, IM-23 PROCEDURE FOR PREPARING RECORDS INVENTORY AND DISPOSITION SCHEDULES (RIDS) 1. If the records have not yet been inventoried, see "Procedure for Conducting a Records Inventory." An inventory must be completed prior to preparing the RIDS. 2. The Records Inventory and Disposition Schedules (RIDS) should be reviewed and updated at least annually on DOE F 1324.10 and DOE F 1324.9. The RIDS covers all record, administrative and programmatic, as well as non- record material. The RIDS must include: a. Complete and detailed information identifying the organization (s) responsible for the records.

266

Statistical simulation procedures  

E-Print Network [OSTI]

. Ringer This thesis investicates methods for estimating statistical distribution functions which cannot be easily solved by theoretical techniques. The stratified Ilonte Carlo procedure of Ringer and Suharto [11j is extended to the multivariate case... and applied to two probIems, one practical, the other theoretical. This procedure Is shown to be more precise than simple Monte Carlo simula- t. i on. numerical method proposed by Soserville [12j is also extended to the multivariate case, and compared...

Tremelling, Robert Norman

2012-06-07T23:59:59.000Z

267

Ceramic fabricator quality revolution: A case study  

SciTech Connect (OSTI)

This case study discusses statistical process control and other quality tools in the application of continuous improvement and total quality management programs to a mature ceramic parts manufacturing operation that had been producing quality'' products for many years. By applying these tools, significant incremental improvements in process performance and product quality were achieved.

Martin, S.C. (Advanced Refractory Technologies, Inc., Buffalo, NY (United States))

1993-11-01T23:59:59.000Z

268

E-Print Network 3.0 - air quality simulation Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: Commission on Environmental Quality, Saffett Tanrikulu Bay Area Air Quality Control District, Jon Pleim- EPA... for SIPs and air quality forecasting Problem to be...

269

Assessment of compliance costs resulting from implementation of the proposed Great Lakes water quality guidance  

SciTech Connect (OSTI)

The primary purpose of the study was to develop an estimate of the incremental cost to direct dischargers resulting from the implementation of the proposed Great Lakes Water Quality Guidance (GLWQG). This estimate reflects the incremental cost of complying with permit requirements developed using the Implementation Procedures and water quality criteria proposed in the GLWQG versus permit requirements based on existing State water quality standards. Two secondary analyses were also performed, one to develop a preliminary estimate of the costs that would be incurred by indirect dischargers to publicly owned treatment works (POTWs), and another to evaluate the cost-effectiveness of the GLWQG. Finally, several sensitivity analyses were performed to evaluate the impact of several major assumptions on the estimated compliance costs. To estimate compliance costs, permit limitations and conditions based on existing State water quality standards were compared to water quality-based limitations and conditions based on the proposed GLWQG criteria and Implementation Procedures for a sample of plants. The control measures needed to comply with the proposed GLWQG-based effluent limitations were evaluated. Individual plant compliance costs were estimated for these control measures based on information on treatment technology and cost analyses available in the literature. An overall compliance cost was projected from the sample based on statistical methods.

Fenner, K.; Podar, M.; Snyder, B.

1993-04-16T23:59:59.000Z

270

Quality Assurance Program Plan | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Quality Assurance Program Plan Quality Assurance Program Plan Quality Assurance Program Plan The achievement of quality in LM activities and products requires implementation of a formal Quality Assurance (QA) Program. This program establishes principles, requirements, practices, and methods for integrating quality into the daily operations of our programs and projects. The QA Program functions as a management tool to ensure that quality objectives are achieved throughout LM's technical, administrative, and operational functions. Achieving quality is the responsibility of managers as well as those who perform the work. Each employee is expected to do the job in accordance with procedures and other requirements. The name LM must represent quality to us, our customers, our service providers, and our

271

Consistency of FMEA used in the validation of analytical procedures  

Science Journals Connector (OSTI)

In order to explore the consistency of the outcome of a Failure Mode and Effects Analysis (FMEA) in the validation of analytical procedures, an FMEA was carried out by two different teams. The two teams applied two separate \\{FMEAs\\} to a High Performance Liquid Chromatography–Diode Array Detection–Mass Spectrometry (HPLC–DAD–MS) analytical procedure used in the quality control of medicines. Each team was free to define their own ranking scales for the probability of severity (S), occurrence (O), and detection (D) of failure modes. We calculated Risk Priority Numbers (RPNs) and we identified the failure modes above the 90th percentile of RPN values as failure modes needing urgent corrective action; failure modes falling between the 75th and 90th percentile of RPN values were identified as failure modes needing necessary corrective action, respectively. Team 1 and Team 2 identified five and six failure modes needing urgent corrective action respectively, with two being commonly identified. Of the failure modes needing necessary corrective actions, about a third were commonly identified by both teams. These results show inconsistency in the outcome of the FMEA. To improve consistency, we recommend that FMEA is always carried out under the supervision of an experienced FMEA-facilitator and that the FMEA team has at least two members with competence in the analytical method to be validated. However, the \\{FMEAs\\} of both teams contained valuable information that was not identified by the other team, indicating that this inconsistency is not always a drawback.

M.T. Oldenhof; J.F. van Leeuwen; M.J. Nauta; D. de Kaste; Y.M.C.F. Odekerken-Rombouts; M.J. Vredenbregt; M. Weda; D.M. Barends

2011-01-01T23:59:59.000Z

272

Quality Assurance  

Broader source: Energy.gov [DOE]

QUALITY ASSURANCE IN THE DEPARTMENT OF ENERGY DOE has established Quality Policy, Principles and Value Added Requirement Attributes that apply to all work and are focused on performance, customer expectations, and improvement. When properly implemented, the principles and requirements form a management system to plan, perform, assess, and improve work. The requirements are performance oriented and offer unlimited implementation flexibility.

273

Awardee Share Procedures  

Broader source: Energy.gov (indexed) [DOE]

Awardee Share Procedures Awardee Share Procedures Procedures for Correctly Reporting Awardee Share on the FAADS/FAADS Plus reporting screen in STRIPES To ensure proper reporting by DOE to USASpending.gov, you must enter the awardee share (also known as the cost share, recipient share, and non-federal share) manually on the FAADS/FAADS Plus reporting screen in STRIPES. The FAADS/FAADS Plus file is the financial assistance equivalent of the FPDS-NG data entry for acquisition awards. The awardee share amount is not system generated on the FAADS/FAADS Plus reporting screen like the obligation amount is. The fields on the FAADS/FAADS Plus form which must be entered when reporting a Cost-share Financial Assistance Award are: Field #17 Non-Federal Funding Sign Choose 'Obligation', which refers to a positive amount (sign), or 'Deobligation', which refers to a

274

Radiation Emergency Procedure Demonstrations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Managing Radiation Emergencies Managing Radiation Emergencies Procedure Demonstrations Procedure Demonstrations Note: RealPlayer is needed for listening to the narration that accompany these demonstrations. Real Player Dressing To Prevent the Spread of Radioactive Contamination This demonstration shows how your team can dress to prevent the spread of radioactive contamination. Click to begin presentation on dressing to prevent the spread of radioactive contamination. Preparing The Area This demonstration shows basic steps you can take to gather equipment and prepare a room to receive a patient who may be contaminated with radioactive material. Click to begin presentation on preparing a room to receive a radioactive contaminated patient. Removing Contaminated Clothing This demonstration shows the procedure for removing clothing from a patient who may be contaminated with radioactive material.

275

Evidence in European Asylum Procedures.  

E-Print Network [OSTI]

??This thesis explores the particular framework of evidentiary assessment of three selected appellate national asylum procedures in Europe and discusses the relationship between these procedures,… (more)

Staffans, Ida

2011-01-01T23:59:59.000Z

276

Karen Nunez, Procedures Center Manager  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Karen Nunez, Procedures Center Manager Print Procedures Center Manager Karen Nunez has been working somewhat "behind the scenes" at the ALS for the past seven years, ensuring that...

277

Policy Procedure Administrative Directive Title: _____________________________________  

E-Print Network [OSTI]

Policy ­ Procedure ­ Administrative Directive Title: _____________________________________ Policy-President _____________ See also: Related Policies, Procedures and Agreements: Relevant Legislation and Regulations: ____________________________________________________________________________ Background and Purpose: ____________________________________________________________________________ Policy

Northern British Columbia, University of

278

Emergency Procedures | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Services Employee Services Safety and Health Emergency Procedures Emergency Procedures Note: This page is pending deletion, please refer to the Safety and health main page...

279

Wind Power Quality Test for Comparison of Power Quality Standards  

SciTech Connect (OSTI)

Power quality testing is important to wind power applications for several reasons. The nature of wind turbine generation is different from conventional power plants. Although windfarms are growing in capacity and diversifying in nature in the U.S. and throughout the globe, there is no standard that addresses the power quality of wind turbines or wind farms. The International Electrotechnical Committee (IEC) has convened Working Group 10 (WG10) to address testing and assessment of power quality characteristics of wind turbines. A IEEE task force has been appointed to reconsider flicker measurement procedures in the U.S. Lastly, power quality tests are now required as part of the certification process for wind turbines. NREL began this work both in response to industry request and in support of the IEC working group. (Mr. Gregory is a member of the IEC working group) This paper presents the NREL Certification Testing Team's effort in developing procedures and equipment for power quality testing for wind turbine certification. Summaries of several power quality standards that are applicable to this process are also presented in this paper.

Jacobson, R.; Gregory, B. (National Wind Technology Center)

1999-09-09T23:59:59.000Z

280

Plutonium immobilization project development and testing quality assurance program description - February 1999  

SciTech Connect (OSTI)

Lawrence Livermore National Laboratory Immobilization Development and Testing organization (LLNL ID and T) is a Participant in the Plutonium Immobilization Project (PIP). The LLNL D and T has lead responsibilities for form characterization and qualification, ceramic form development, process/equipment development with plutonium, and process systems testing and validation for both conversion and immobilization. This work must be performed in accordance with the graded approach of a Quality Assurance (QA) Program. A QA Program has been developed at LLNL to meet the requirements of the DOE/MD Quality Assurance Requirements. The LLNL QA Program consists of a Quality Assurance Program Description (QAPD) and Quality Implementing Procedures. These documents interface and are a subset of the overall PIP QA Program Documents. The PIP QA Program is described in the PIP ID and T QA Plan, PIP QAPD, and QA Procedures. Other Participant Organizations also must document and describe their PIP compliant QA Programs in a QAPD and implementing procedures. The purpose of this LLNL QAPD is to describe the organization, management processes, QA Controls for Grading, functional responsibilities, levels of authority, and interfaces for those managing, performing, and assessing the adequacy of work.

MacLean, L M; Ziemba, J

1999-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

POLICY AND PROCEDURE MANUAL DENTAL HYGIENE STUDENT  

E-Print Network [OSTI]

Page | 1 POLICY AND PROCEDURE MANUAL FOR THE DENTAL HYGIENE STUDENT DENTAL HYGIENE PROGRAM SCHOOL............................................................................. 14 Notice for Students to File Complaints With the Commission on Dental Accreditation ....................................................................................................18 Policy for the Control and Use of Ionizing Radiation GUIDELINES FOR RADIOLOGY PATIENT

Nickrent, Daniel L.

282

Chemical analysis quality assurance at the Idaho Chemical Processing Plant  

SciTech Connect (OSTI)

The Idaho Chemical Processing Plant (ICPP) is a uranium reprocessing facility operated by Westinghouse Idaho Nuclear Company for the Department of Energy at the Idaho National Engineering Laboratory (INEL). The chemical analysis support required for the plant processes is provided by a chemical analysis staff of 67 chemists, analysts, and support personnel. The documentation and defense of the chemical analysis data at the ICPP has evolved into a complete chemical analysis quality assurance program with training/qualification and requalification, chemical analysis procedures, records management and chemical analysis methods quality control as major elements. The quality assurance procedures are implemented on a central analytical computer system. The individual features provided by the computer system are automatic method selection for process streams, automation of method calculations, automatic assignment of bias and precision estimates at analysis levels to all method results, analyst specific daily requalification or with-method-use requalification, untrained or unqualified analyst method lockout, statistical testing of process stream results for replicate agreement, automatic testing of process results against pre-established operating, safety, or failure limits at varying confidence levels, and automatic transfer and report of analysis data plus the results of all statistical testing to the Production Department.

Hand, R.L.; Anselmo, R.W.; Black, D.B.; Jacobson, J.J.; Lewis, L.C.; Marushia, P.C.; Spraktes, F.W.; Zack, N.R.

1985-01-01T23:59:59.000Z

283

Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities  

SciTech Connect (OSTI)

This Quality Assurance Project Plan addresses the quality assurance requirements for the Facility Monitoring Plans of the overall site-wide environmental monitoring plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of individual Facility Effluent Monitoring Plans. This document is intended to be a basic road map to the Facility Effluent Monitoring Plan documents (i.e., the guidance document for preparing Facility Effluent Monitoring Plans, Facility Effluent Monitoring Plan determinations, management plan, and Facility Effluent Monitoring Plans). The implementing procedures, plans, and instructions are appropriate for the control of effluent monitoring plans requiring compliance with US Department of Energy, US Environmental Protection Agency, state, and local requirements. This Quality Assurance Project Plan contains a matrix of organizational responsibilities, procedural resources from facility or site manuals used in the Facility Effluent Monitoring Plans, and a list of the analytes of interest and analytical methods for each facility preparing a Facility Effluent Monitoring Plan. 44 refs., 1 figs., 2 tabs.

Nickels, J.M.

1991-06-01T23:59:59.000Z

284

EMERGENCY PLANNING AND PROCEDURES  

E-Print Network [OSTI]

EMERGENCY PLANNING AND PROCEDURES HANDBOOK FOR CWRU EMPLOYEES August 2013 #12;CWRU EMERGENCY innovation, technology, teamwork, public- private co- operation and vigilance. Mission Statement We increase appropriately to any crisis or emergency. This handbook is comprehensive and provides employees with information

Cavusoglu, Cenk

285

EMERGENCY PLANNING AND PROCEDURES  

E-Print Network [OSTI]

EMERGENCY PLANNING AND PROCEDURES HANDBOOK FOR CWRU STUDENTS August 2013 #12;CWRU EMERGENCY innovation, technology, teamwork, public- private co- operation and vigilance. Mission Statement We increase. This handbook is comprehensive and provides studetns with information on how to prepare for and respond

Cavusoglu, Cenk

286

BOMB THREAT CALL PROCEDURES  

E-Print Network [OSTI]

THREAT CALL PROCEDURES BOMB THREAT CHECKLIST Date: Time: Time Caller Phone Number Where Hung Up: Call Received:Most bomb threats are received by phone. Bomb threats are serious until proven otherwise. Act threat is received by phone: 1. Remain calm. Keep the caller on the line for as long as possible. DO

Guo, Ting

287

BOMB THREAT CALL PROCEDURES  

E-Print Network [OSTI]

BOMB THREAT CALL PROCEDURES WHO TO CONTACT (select one) · Follow your local guidelines · Federal Protective Service (FPS) Police 1-877-4-FPS-411 (1-877-437-7411) · 911 Most bomb threats are received by phone. Bomb threats are serious until proven otherwise. Act quickly, but remain calm and obtain

Boyce, Richard L.

288

Building Programming List Procedures  

E-Print Network [OSTI]

1 6.090 Building Programming Experience Lecture 4 1/16/2007 Outline · List Procedures · Compound)) (define (reverse-helper l r) (if (null? l) r (reverse-helper (cdr l) (cons (car l) r)))) list-ref · Write

289

EMERGENCY PROCEDURES --2013 INFORMATION  

E-Print Network [OSTI]

quickly, remain calm. Take personal items (keys, purse, wallet, coat, shoes) Secure any hazardous procedures. SHOOTING INCIDENT If shooter is outside building: Turn off lights, lock windows and doors, close police. If shooter is inside the building: If safe to exit, flee. Call 9-1-1 to give location. Do

290

EMERGENCY PROCEDURES --2014 INFORMATION  

E-Print Network [OSTI]

hazardous materials. Close door when you exit. Go to evacuation assembly point designated by evacu- ation procedures. SHOOTING INCIDENT If shooter is outside building: Turn off lights, lock windows and doors, close of uniformed police. If shooter is inside the building: If safe to exit, flee. Call 9-1-1 to give location

291

Quality Policy  

Broader source: Energy.gov [DOE]

Quality Policy It is the policy of the Department of Energy to establish quality requirements to ensure that risks and environmental impacts are minimized and that safety, reliability, and performance are maximized through the application of effective management systems commensurate with the risks posed by the facility or activity and its work. The Department implements this policy through the QA Order and the QA rule directives to ensure quality assurance requirements are clearly specified for the broad spectrum of work performed by DOE and its contractors.

292

Relationship of the HACCP system to Total Quality Management  

Science Journals Connector (OSTI)

Webster’s Dictionary (1989) defines quality as ‘a degree of excellence or superiority in kind’. The American Society for Quality Control (ASQC, 1987) specifies that quality is ‘the totality of feat...

N. B. Webb; J. L. Marsden

1995-01-01T23:59:59.000Z

293

Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

What We Monitor & Why » What We Monitor & Why » Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data monitoring for particulate matter An air monitoring field team member tests one of LANL's tapered element oscillating microbalance samplers, which collects real-time particulate matter data. Contact Environmental Communication & Public Involvement P.O. Box 1663 MS M996 Los Alamos, NM 87545 (505) 667-0216 Email LANL monitors air quality 24 hours a day, 365 days a year. Why we monitor air LANL monitors many different pathways in order to assess their impact on workers, the public, animals, and plants. We monitor the air around the Laboratory to ensure our operations are not affecting the air of nearby

294

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To establish an effective management system [i.e., quality assurance programs (QAPs)] using the performance requirements of this Order, coupled with technical standards where appropriate. Cancels DOE O 414.1.

1999-09-29T23:59:59.000Z

295

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order defines roles and responsibilities for providing quality assurance for DOE products and services. Cancels DOE O 414.1C. Admin Chg 1, dated 5-8-13, cancels DOE O 414.1D.

2011-04-25T23:59:59.000Z

296

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Order ensures that the quality of DOE/NNSA products and services meets or exceeds the customers' expectations. Cancels DOE O 414.1B and DOE N 411.1. Canceled by DOE O 414.1D.

2005-06-17T23:59:59.000Z

297

Louisiana Air Control Law (Louisiana)  

Broader source: Energy.gov [DOE]

This law states regulations for air quality control and states the powers and duties of the secretary of environmental quality. It provides information about permits and licenses, air quality...

298

Procedures for Departing Employees | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Procedures for Departing Employees Procedures for Departing Employees RM Exit Procedures (2)3.12.12.pdf More Documents & Publications Procedures for Departing Employees Records...

299

Procedures for Departing Employees | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Procedures for Departing Employees Procedures for Departing Employees RM Exit Procedures.doc More Documents & Publications Procedures for Departing Employees Records Management...

300

Regulations for Air Quality (Quebec, Canada)  

Broader source: Energy.gov [DOE]

This Regulation establishes emission standards for particulates and gases, emission opacity standards, standards of air quality and control measures to prevent, eliminate or reduce the emission of...

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

DOE Order on Quality Assurance  

Broader source: Energy.gov (indexed) [DOE]

INITIATED BY: INITIATED BY: www.directives.doe.gov Office of Health, Safety and Security U.S. Department of Energy ORDER Washington, D.C. Approved: 4-25-2011 SUBJECT: QUALITY ASSURANCE 1. PURPOSE. a. To ensure that Department of Energy (DOE), including National Nuclear Security Administration (NNSA), products and services meet or exceed customers' requirements and expectations. b. To achieve quality for all work based upon the following principles: (1) All work, as defined in this Order, is conducted through an integrated and effective management system; (2) Management support for planning, organization, resources, direction, and control is essential to quality assurance (QA); (3) Performance and quality improvement require thorough, rigorous

302

TRANSPARENCY RECYCLING PROGRAM PROCEDURES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

TRANSPARENCY RECYCLING Don't throw out your used overhead transparencies! RECYCLE them for REUSE. It's Easy! Follow these simple procedures: 1.) COLLECT used transparencies to be recycled. 2.) SEPARATE the transparencies from ringed binders, plastic or paper folders, envelopes, and/or files. 3.) PLACE the transparencies (only) into an intra-laboratory mail envelope. 4.) SEND the envelope to: Terri Schneider, Building 201, 1D-10. Terri will prepare a

303

Nuclear Safety: Software Quality Assurance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Nuclear Safety: Software Quality Assurance Nuclear Safety: Software Quality Assurance cd Welcome to the Department of Energy's Office of Health, Safety and Security (HSS) Software Quality Assurance (SQA) homepage. The purpose of this Web site is to promote continuous improvement and the sharing of knowledge of safety software quality assurance among interested parties across the DOE complex. It consolidates information and contains links to subject matter experts, procedures, training material, program descriptions, good practices, lessons learned and the Central Registry Toolbox Codes. The Portal also provides capabilities for member collaboration in product development and threaded discussions. Central Registry: The Central Registry provides a library of DOE "Toolbox" Codes covering site boundary accident dose consequences, fire accident source terms, leakpath factors, chemical release/dispersion and consequence, and radiological dispersion and consequence.

304

Urban and Regional Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

equipment equipment Urban and Regional Air Quality Research in this area is concerned with regional air quality issues such as: Controlling nitrogen oxides (NOx) and volatile organic compounds, to manage tropospheric ozone pollution. Hazardous air pollutants: using science to base standards on rigorously studied risks. Air quality and climate: how does climate influence air quality at a regional or local level? Current modeling practices often do not capture variations in pollutants such as ozone-they represent a limited sample of the diverse meteorology and human behavior that affect air pollution. Improved modeling of regional air quality will help understand variability, reveal patterns of behavior, and pollutant transport issues. Controlled experiments in lab and field can help validate improved models.

305

CRITIQUING TEAM PROCEDURE EXECUTION Stephanie Guerlain Peter Bullemer  

E-Print Network [OSTI]

3-515 CRITIQUING TEAM PROCEDURE EXECUTION Stephanie Guerlain Peter Bullemer University of Virginia a single person performing a static, non time-critical task. We have now' developed a critiquing system in the more dynamic world of process control. Specifically, we support the execution of complex procedures

Virginia, University of

306

DOE NEPA Implementing Procedures: Final Rule (61 Fed Reg 64603) |  

Broader source: Energy.gov (indexed) [DOE]

NEPA Implementing Procedures: Final Rule (61 Fed Reg 64603) NEPA Implementing Procedures: Final Rule (61 Fed Reg 64603) DOE NEPA Implementing Procedures: Final Rule (61 Fed Reg 64603) DOE amended its regulations governing compliance with the National Environmental Policy Act (NEPA). These amendments incorporate changes primarily related to DOE's power marketing activities, based on DOE's experience in applying the current NEPA regulations. The revised regulations are intended to improve DOE's efficiency in implementing NEPA requirements by reducing costs and preparation time, while maintaining quality, consistent with the DOE Secretarial Policy Statement on NEPA issued in June 1994. 61 Fed Reg 64603: DOE NEPA Implementing Procedures-Final Rule More Documents & Publications DOE NEPA Implementing Procedures: Final Rule (61 Fed Reg 36222)

307

EM Quality Assurance Policy, Revision 0  

Broader source: Energy.gov (indexed) [DOE]

Office of Environmental Management Corporate Quality Policy Office of Environmental Management Corporate Quality Policy The Office of Environmental Management recognizes that individuals performing work determine whether it is done correctly in accordance with all requirements and therefore achieves quality. Although "do work safely" is our first priority, we understand it is also essential to "do work correctly" or both safety and quality are jeopardized. While plans, procedures, and instructions are commonly understood elements of any quality program, people make quality happen and allow us to deliver on our commitments. As the Assistant Secretary for Environmental Management (EM), I am responsible to achieve quality within my organization. It is EM policy that doing work correctly is not

308

Property:FieldProcedures | Open Energy Information  

Open Energy Info (EERE)

FieldProcedures FieldProcedures Jump to: navigation, search Property Name FieldProcedures Property Type Text Description Description of actions, equipment and footprint of the exploration activity Subproperties This property has the following 39 subproperties: A Active Seismic Techniques Airborne Gravity Survey Audio-Magnetotellurics C Controlled Source Audio MT Cross-Dipole Acoustic Log D DC Resistivity Survey (Dipole-Dipole Array) DC Resistivity Survey (Mise-Á-La-Masse) DC Resistivity Survey (Pole-Dipole Array) DC Resistivity Survey (Schlumberger Array) DC Resistivity Survey (Wenner Array) Development Drilling Direct-Current Resistivity Survey Drilling Techniques E Earth Tidal Analysis Electrical Profiling Configurations Electromagnetic Techniques Exploration Drilling F FMI Log Frequency-Domain Electromagnetic Survey

309

The Association between Postdiagnosis Dietary Supplement Use and Total Mortality Differs by Diet Quality among Older Female Cancer Survivors  

Science Journals Connector (OSTI)

...730: A prototype device for quality control of cancer specimens...A Fluorescence Resonance Energy Transfer (FRET)-based SPTAN1...platform dedicated to specimen quality control. This foundational...Vortmeyer. A prototype device for quality control of cancer specimens...

Maki Inoue-Choi; Heather Greenlee; Sarah J. Oppeneer; and Kim Robien

2014-05-01T23:59:59.000Z

310

Review article Tomato fruit quality in relation  

E-Print Network [OSTI]

Review article Tomato fruit quality in relation to water and carbon fluxes Soraya GUICHARDa, Nadia in the formation of tomato fruit quality. This approach has provided new insights that help in understanding and controlling some of the major variables of fruit quality. Variations in the concentration of dry matter

Paris-Sud XI, Université de

311

Rough Ride Test Procedure  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

NTP005 NTP005 Revision 2 Effective December 1, 2004 Electric Vehicle Rough Road Course Test Prepared by Electric Transportation Applications Prepared by: _______________________________ Date:__________ Ryan Harkins Approved by: _________________________________________________ Date: _______________ Donald B. Karner ©2004 Electric Transportation Applications All Rights Reserved Procedure ETA-NTP005 Revision 2 2 TABLE OF CONTENTS 1.0 Objectives 3 2.0 Purpose 3 3.0 Documentation 3 4.0 Initial Conditions and Prerequisites 4 5.0 Testing Activity Requirements 6 6.0 Glossary 12 7.0 References 14 Appendices Appendix A - Electric Vehicle Rough Road Test Data Sheet 15

312

Energy Metering Audit Procedure  

E-Print Network [OSTI]

Energy Meterilg Audtt Procedure Wiliam S Whitaker Engineering Specialist T X E INC. laPorte Texas INTROOUCI'ION This paper describes the recent audit of the utility distriooticn meters in a petrochanica1 plant. These meters measure the steam..., cx:ndensate, natural gas, water, nitrogen and air flCMS to the different process units within the plant. This audit started as an attellPt to resolve discrepan::ies between the 650 PSIG steam distriootion and supply meters. Theoretically the sum...

Whitaker, W. S.

313

Surface cleanliness measurement procedure  

DOE Patents [OSTI]

A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.

Schroder, Mark Stewart (Hendersonville, NC); Woodmansee, Donald Ernest (Simpsonville, SC); Beadie, Douglas Frank (Greenville, SC)

2002-01-01T23:59:59.000Z

314

Quality assurance program plan fuel supply shutdown  

SciTech Connect (OSTI)

This Quality Assurance Program plan (QAPP) describes how the Fuel Supply Shutdown (FSS) project organization implements the quality assurance requirements of HNF-MP-599, Project Hanford Quality Assurance Program Description (QAPD) and the B and W Hanford Company Quality Assurance Program Plan (QAPP), FSP-MP-004. The QAPP applies to facility structures, systems, and components and to activities (e.g., design, procurement, testing, operations, maintenance, etc.) that could affect structures, systems, and components. This QAPP also provides a roadmap of applicable Project Hanford Policies and Procedures (PHPP) which may be utilized by the FSS project organization to implement the requirements of this QAPP.

Metcalf, I.L.

1998-09-21T23:59:59.000Z

315

ECOLOGIC REGRESSION ANALYSIS AND THE STUDY OF THE INFLUENCE OF AIR QUALITY ON MORTALITY  

E-Print Network [OSTI]

Control II Variables Air Quality Regression CoefficientsAppendices A. Sources of Air Quality and 11 Control" Data B.The relationship of air quality to disease has been

Selvin, S.

2014-01-01T23:59:59.000Z

316

ON CONSISTENCY OF BAYES PROCEDURES  

Science Journals Connector (OSTI)

ON CONSISTENCY OF BAYES PROCEDURES Loraine Schwartz DEPARTMENT OF MATHEMATICS, UNIVERSITY OF BRITISH COLUMBIA...COLUMBIA. | Journal Article ON CONSISTENCY OF BAYES PROCEDURES BY LORAINE SCHWARTZ DEPARTMENT OF MATHEMATICS, UNIVERSITY OF BRITISH COLUMBIA...

Loraine Schwartz

1964-01-01T23:59:59.000Z

317

Quality Assurance: Underlying Quality Principles  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Underlying Quality Principles Underlying Quality Principles These principles are consistent with Integrated Safety Management Policy, P 450.4A and support ISM implementation. Define Policies and Objectives--Ensure they are Understood and Accepted. Management must set expectations for the organization as a whole before employees can do their jobs, satisfy their customers, and strive to improve the quality of their work. This is accomplished by developing and implementing specific policies and objectives that reflect the operating philosophy of the facility's management. Once these policies and objectives have been established, all managers must take the necessary actions to ensure that each employee shares their vision of the organization's purpose. Specify Roles and Responsibilities--Ensure they are Understood and Accepted.

318

Improving Stormwater Quality  

E-Print Network [OSTI]

it alters what and how stormwater flows in each watershed. Construction activities inherent to urbanization replace natural groundcover with impervious surfaces such as buildings, roads, and parking lots that do not allow rainfall to penetrate the soil... Stormwater QualityStory by Raul L. Garcia tx H2O | pg. 18 The City of Houston, Harris County, theHarris County Flood Control District and the Texas Department of Transportation have teamed up through a Joint Task Force (JTF) to address Houston...

Garcia, Raul

2005-01-01T23:59:59.000Z

319

Shrinking Procedures and Optimal Algorithms  

E-Print Network [OSTI]

Jun 18, 2012 ... Optimal Stochastic Approximation Algorithms for Strongly Convex Stochastic Composite Optimization, II: Shrinking Procedures and Optimal ...

Saeed Ghadimi

2012-06-18T23:59:59.000Z

320

Patient radiation dose audits for fluoroscopically guided interventional procedures  

SciTech Connect (OSTI)

Purpose: Quality management for any use of medical x-ray imaging should include monitoring of radiation dose. Fluoroscopically guided interventional (FGI) procedures are inherently clinically variable and have the potential for inducing deterministic injuries in patients. The use of a conventional diagnostic reference level is not appropriate for FGI procedures. A similar but more detailed quality process for management of radiation dose in FGI procedures is described. Methods: A method that takes into account both the inherent variability of FGI procedures and the risk of deterministic injuries from these procedures is suggested. The substantial radiation dose level (SRDL) is an absolute action level (with regard to patient follow-up) below which skin injury is highly unlikely and above which skin injury is possible. The quality process for FGI procedures collects data from all instances of a given procedure from a number of facilities into an advisory data set (ADS). An individual facility collects a facility data set (FDS) comprised of all instances of the same procedure at that facility. The individual FDS is then compared to the multifacility ADS with regard to the overall shape of the dose distributions and the percent of instances in both the ADS and the FDS that exceed the SRDL. Results: Samples of an ADS and FDS for percutaneous coronary intervention, using the dose metric of reference air kerma (K{sub a,r}) (i.e., the cumulative air kerma at the reference point), are used to illustrate the proposed quality process for FGI procedures. Investigation is warranted whenever the FDS is noticeably different from the ADS for the specific FGI procedure and particularly in two circumstances: (1) When the facility's local median K{sub a,r} exceeds the 75th percentile of the ADS and (2) when the percent of instances where K{sub a,r} exceeds the facility-selected SRDL is greater for the FDS than for the ADS. Conclusions: Analysis of the two data sets (ADS and FDS) and of the percent of instances that exceed the SRDL provides a means for the facility to better manage radiation dose (and therefore both deterministic and stochastic radiation risk) to the patient during FGI procedures.

Balter, Stephen; Rosenstein, Marvin; Miller, Donald L.; Schueler, Beth; Spelic, David [Department of Radiology and Department of Medicine, Columbia University, New York, New York 10032 (United States); Clarksburg, Maryland 20871 (United States); Department of Radiology, F. Edward Hebert School of Medicine, Uniformed Services University, Bethesda, Maryland 20814 (United States); Department of Radiology, Mayo Clinic and Foundation, Rochester, Minnesota 55905 (United States); Division of Mammography Quality and Radiation Programs, Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland 20903 (United States)

2011-03-15T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Handbook of Academic Requirements & Procedures  

E-Print Network [OSTI]

Handbook of Academic Requirements & Procedures for the Chemistry/Biotechnology Graduate Program. A detailed account of the academic requirements and procedures is provided for graduate students in chemistry; to promote consistency in procedures and standards; and to provide a basis for communication between

Kounaves, Samuel P.

322

Postgraduate Admissions Policy and Procedures  

E-Print Network [OSTI]

1 Postgraduate Admissions Policy and Procedures SCOPE OF POLICY This policy applies to all to both staff and applicants on the University's procedures for admitting postgraduate students PROCEDURES 5 3.1 Making an application 5 3.2 Application deadlines 5 3.3 Accreditation of Prior Learning (APL

323

PROCEDURES FOR THE APPOINTMENT AND  

E-Print Network [OSTI]

1 PROCEDURES FOR THE APPOINTMENT AND RE-APPOINTMENT OF THE UNIVERSITY LIBRARIAN University Policy PURPOSE 1.00 The following procedures define the method by which the appointment, or review and re-appointment, of the university librarian will be conducted. SCOPE 2.00 These procedures apply to: the appointment of a new

Victoria, University of

324

PROCEDURES FOR THE APPOINTMENT AND  

E-Print Network [OSTI]

Page | 1 PROCEDURES FOR THE APPOINTMENT AND RE-APPOINTMENT OF ACADEMIC ASSOCIATE VICE Review: February, 2018 PURPOSE 1.00 The following procedures define the method by which the appointment.00 These procedures apply to the appointment and reappointment of academic Associate Vice-Presidents. An Academic

Victoria, University of

325

PROCEDURES FOR THE APPOINTMENT AND  

E-Print Network [OSTI]

Page | 1 PROCEDURES FOR THE APPOINTMENT AND RE-APPOINTMENT OF DEANS University Policy No: GV0450 procedures define the method by which the appointment, or review and re-appointment, of deans will be conducted. SCOPE 2.00 These procedures apply to: the appointments of new deans, the review and re

Victoria, University of

326

Handbook of Academic Requirements & Procedures  

E-Print Network [OSTI]

Handbook of Academic Requirements & Procedures for the Chemistry Graduate Program PLEASE NOTE and procedures is provided. The intent is to describe the programs and explain the rationale behind them of the Department; to promote consistency in procedures and standards; and to provide a basis for communication

Kounaves, Samuel P.

327

PROCEDURES FOR THE APPOINTMENT AND  

E-Print Network [OSTI]

Page 1 PROCEDURES FOR THE APPOINTMENT AND RE-APPOINTMENT OF THE ASSOCIATE DEAN ACADEMIC ADVISING Last Editorial Change: Mandated Review: May, 2018 PURPOSE 1.00 The following procedures define (Faculties of Science, Social Sciences and Humanities) will be conducted. SCOPE 2.00 These procedures apply

Victoria, University of

328

Capital Projects Delivery Procedures Manual  

E-Print Network [OSTI]

1 Capital Projects Delivery Procedures Manual September 4, 2008 Office of the CFO #12;2 Page I of the Capital Budget 11 B. Budget Approval 12 C. Setting Up Capital Projects 13 III. Procedures for Design ­ Office of the Chief Financial Officer Financial Policies and Procedures for the Capital Project Delivery

Alpay, S. Pamir

329

Factors controlling reservoir quality in tertiary sandstones and their significance to geopressured geothermal production. Annual report, May 1, 1979-May 31, 1980  

SciTech Connect (OSTI)

Differing extents of diagenetic modification is the factor primarily responsible for contrasting regional reservoir quality of Tertiary sandstones from the Upper and Lower Texas Gulf Coast. Detailed comparison of Frio sandstones from the Chocolate Bayou/Danbury Dome area, Brazoria County, and Vicksburg sandstones from the McAllen Ranch Field area, Hidalgo County, reveals that extent of diagenetic modification is most strongly influenced by (1) detrital mineralogy and (2) regional geothermal gradients. Vicksburg sandstones from the McAllen Ranch Field area are less stable, chemically and mechanically, than Frio sandstones from the Chocolate Bayou/Danbury dome area. Vicksburg sandstones are mineralogically immature and contain greater proportions of feldspars and rock fragments than do Frio sandstones. Thr reactive detrital assemblage of Vicksubrg sandstones is highly susceptible to diagenetic modification. Susceptibility is enhanced by higher than normal geothermal gradients in the McAllen Ranch Field area. Thus, consolidation of Vicksburg sandstones began at shallower depth of burial and precipitation of authigenic phases (especially calcite) was more pervasive than in Frio sandstones. Moreover, the late-stage episode of ferroan calcite precipitation that occluded most secondary porosity in Vicksburg sandstones did not occur significantly in Frio sandstones. Therefore, regional reservoir quality of Frio sandstones from Brazoria County is far better than that characterizing Vicksburg sandstones from Hidalgo County, especially at depths suitable for geopressured geothermal energy production.

Loucks, R.G.; Richmann, D.L.; Milliken, K.L.

1980-07-01T23:59:59.000Z

330

Records Management Exit Procedures  

Broader source: Energy.gov (indexed) [DOE]

Exit Procedures For Departing Federal and contractor Employees PRESERVATION OF FEDERAL RECORDS The Federal Records Act requires the Department of Energy (DOE) Records Officer to remind departing Federal and contractor employees that Federal records may not be removed from Government custody nor may they be destroyed except in accordance with a records disposition schedule that has been approved by the Archivist of the United States. The creation of adequate documentation and the preservation of Federal records are required by law and regulation (contained in 36 CFR Chapter XII). As Federal and contractor employees, you have Federal record-keeping responsibilities that are regulated by the National Archives and Records Administration (NARA) to ensure the retention and

331

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To establish an effective management system [i.e., quality assurance programs(QAPs)] using the performance requirements of this Order, coupled with technical standards where appropriate. Change 1, dated 7/12/01, facilitates the Department's organizational transition necessitated by establishment of the NNSA. (Attachment 2 of this Order is canceled by DOE O 470.2B.) Cancels: DOE O 414.1

2001-07-12T23:59:59.000Z

332

NEPA Implementation Procedures: Appendices I, II, and III | Department of  

Broader source: Energy.gov (indexed) [DOE]

NEPA Implementation Procedures: Appendices I, II, and III NEPA Implementation Procedures: Appendices I, II, and III NEPA Implementation Procedures: Appendices I, II, and III These appendices are intended to improve public participation and facilitate agency compliance with the National Environmental Policy Act (NEPA) and the Council on Environmental Quality's NEPA Regulations, the last version appeared in the Federal Register of Friday, December 21,1984 (49 FR 49754). Note: The specfic contact information is outdated and should not be used for consultation or outreach. Appendix I - Federal and Federal-State Agency NEPA Contacts Appendix II - Federal and Federal- State Agencies With Jurisdiction by Law or Special Expertise on Environmental Quality Issues Appendix III - Federal and Federal-State Agency Offices for

333

Applying Infrared Thermography as a Quality-Control Tool for the Rapid Detection of Proton-Electrolyte-Membrane-Fuel-Cell Catalyst-Layer-Thickness Variations  

SciTech Connect (OSTI)

As fuel cells become more prominent, new manufacturing and production methods are needed to enable increased volumes with high quality. One necessary component of this industrial growth will be the accurate measurement of the variability of a wide range of material properties during the manufacturing process. In this study, a method to detect defects in fuel cell catalyst layers is investigated through experiment and mathematical simulation. The method uses infrared thermography and direct-current electronic-excitation methods to detect variations in platinum-containing catalyst-layer thickness with high spatial and temporal resolution. Data analysis, operating-condition impacts, and detection limits are explored, showing the measurement of defects on the millimeter length scale. Overall, the experimental and modeling results demonstrate great potential of this technique as a nondestructive method to measure defects that is amenable to use on roll-to-roll manufacturing lines.

Aieta, N. V.; Das, P. K.; Perdue, A.; Bender, G.; Herring, A. M.; Weber, A. Z.; Ulsh, M. J.

2012-08-01T23:59:59.000Z

334

The Meaning of Quality in Kinship Foster Care: Caregiver, Child, and Worker Perspectives  

E-Print Network [OSTI]

Though principles, guidelines, and procedures for assessing the quality of foster care in kinship settings have been introduced, research on the factors that mediate the quality and outcome of kinship care has been ...

Chipman, Robert; Wells, Susan J.; Johnson, Michelle A.

2002-01-01T23:59:59.000Z

335

Conditional Depletion of the Chlamydomonas Chloroplast ClpP Protease Activates Nuclear Genes Involved in Autophagy and Plastid Protein Quality Control  

Science Journals Connector (OSTI)

...intense peaks. Four different search engines were employed to achieve spectra-to-peptide...could be recognized by all four search engines. Protein abundance was quantified using...control in noncoding RNA biogenesis. Cold Spring Harb. Symp. Quant. Biol. 71 : 505-511...

Silvia Ramundo; David Casero; Timo Mühlhaus; Dorothea Hemme; Frederik Sommer; Michèle Crèvecoeur; Michèle Rahire; Michael Schroda; Jannette Rusch; Ursula Goodenough; Matteo Pellegrini; Maria Esther Perez-Perez; José Luis Crespo; Olivier Schaad; Natacha Civic; Jean David Rochaix

2014-05-30T23:59:59.000Z

336

Construction quality assurance report  

SciTech Connect (OSTI)

This report provides a summary of the construction quality assurance (CQA) observation and test results, including: The results of the geosynthetic and soil materials conformance testing. The observation and testing results associates with the installation of the soil liners. The observation and testing results associated with the installation of the HDPE geomembrane liner systems. The observation and testing results associated with the installation of the leachate collection and removal systems. The observation and testing results associated with the installation of the working surfaces. The observation and testing results associated with in-plant manufacturing process. Summary of submittal reviews by Golder Construction Services, Inc. The submittal and certification of the piping material specifications. The observation and verification associated of the Acceptance Test Procedure results of the operational equipment functions. Summary of the ECNs which are incorporated into the project.

Roscha, V.

1994-09-08T23:59:59.000Z

337

NETL: IEP - Air Quality Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Home > Technologies > Coal & Power Systems > Innovations for Existing Plants > Air Quality Research Home > Technologies > Coal & Power Systems > Innovations for Existing Plants > Air Quality Research Innovations for Existing Plants Air Quality Research Ambient Monitoring Emissions Characterization Predictive Modeling & Evaluation Health Effects Regulatory Drivers Air Quality Research Reference Shelf The NETL Air Quality Research program is designed to resolve the scientific uncertainties associated with the atmospheric formation, distribution, and chemical transformation of pollutant emissions from today's coal-fired power plants, and to obtain a realistic assessment of the human health impacts of these emissions. Results of this research will help the DOE Office of Fossil Energy address policy questions regarding coal plant emissions and provide guidance for future emissions control R&D programs at

338

Procedures for Interagency Consultation to Avoid or Mitigate Adverse Effects on Rivers in the Nationwide Inventory  

Broader source: Energy.gov [DOE]

These Council on Environmental Quality (CEQ) procedures are designed to assist federal officials in complying with the President's directive to protect rivers in the Nationwide Inventory through the normal environmental analysis process.

339

Current Human Reliability Analysis Methods Applied to Computerized Procedures  

SciTech Connect (OSTI)

Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no US nuclear power plant has implemented CPs in its main control room (Fink et al., 2009). Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of enhanced ease of use and easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

Ronald L. Boring

2012-06-01T23:59:59.000Z

340

PHYSICAL PLANT POLICY & PROCEDURE  

E-Print Network [OSTI]

network and power type oil filled transformers), E-33 (high voltage network and power dry type switches, transformers, and associated equipment. RESPONSIBILITY ACTION DIRECTOR Ensure that all related transformers), E-34 (disconnects), E-34A (disconnects), E-35 (motor control center and motor starters), E-37

Fernandez, Eduardo

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Waste Management Quality Assurance Plan  

SciTech Connect (OSTI)

The WMG QAP is an integral part of a management system designed to ensure that WMG activities are planned, performed, documented, and verified in a manner that assures a quality product. A quality product is one that meets all waste acceptance criteria, conforms to all permit and regulatory requirements, and is accepted at the offsite treatment, storage, and disposal facility. In addition to internal processes, this QA Plan identifies WMG processes providing oversight and assurance to line management that waste is managed according to all federal, state, and local requirements for waste generator areas. A variety of quality assurance activities are integral to managing waste. These QA functions have been identified in the relevant procedures and in subsequent sections of this plan. The WMG QAP defines the requirements of the WMG quality assurance program. These requirements are derived from Department of Energy (DOE) Order 414.1C, Quality Assurance, Contractor Requirements Document, the LBNL Operating and Assurance Program Plan (OAP), and other applicable environmental compliance documents. The QAP and all associated WMG policies and procedures are periodically reviewed and revised, as necessary, to implement corrective actions, and to reflect changes that have occurred in regulations, requirements, or practices as a result of feedback on work performed or lessons learned from other organizations. The provisions of this QAP and its implementing documents apply to quality-affecting activities performed by the WMG; WMG personnel, contractors, and vendors; and personnel from other associated LBNL organizations, except where such contractors, vendors, or organizations are governed by their own WMG-approved QA programs.

Waste Management Group

2006-08-14T23:59:59.000Z

342

Statistical procedures for addressing nondetect results in environmental analyses  

SciTech Connect (OSTI)

Censor data sets, those containing observations that are less than the analytical chemistry limit of detection (LOD) value, are becoming more common as regulatory agencies and dischargers strive to reduce concentrations of trace organic contaminants in treated effluent. The recently reissued Technical Support Document For Water quality Based Toxics Control,'' a frequently used reference during NPDES permit development, states that the mean and variance of censored data sets may be determined by assuming the data conform to what EPA has termed the delta log-normal distribution'' (D-LOG). The US EPA D-LOG statistical procedure along with two commonly used alternatives (Cohen's MLE and regression of normal order scores) are described, illustrated with example calculations and evaluated using Monte Carlo simulation experiments. Using minimal absolute bias as the evaluation criteria, Cohen's method had superior predictive capability overall, particularly for real world data sets. For mean and standard deviation estimators, Cohen's method was at least 2.5 and 1.2 times less biased than those of the EPA recommended methodology, respectively.

Hinton, S.W. (Tufts Univ., Medford, MA (United States). Civil Engineering Dept.)

1994-04-01T23:59:59.000Z

343

Implementation of an Enhanced Measurement Control Program for handling nuclear safety samples at WSRC  

SciTech Connect (OSTI)

In the separation and purification of nuclear material, nuclear criticality safety (NCS) is of primary concern. The primary nuclear criticality safety controls utilized by the Savannah River Site (SRS) Separations Facilities involve administrative and process equipment controls. Additional assurance of NCS is obtained by identifying key process hold points where sampling is used to independently verify the effectiveness of production control. Nuclear safety measurements of samples from these key process locations provide a high degree of assurance that processing conditions are within administrative and procedural nuclear safety controls. An enhanced procedure management system aimed at making improvements in the quality, safety, and conduct of operation was implemented for Nuclear Safety Sample (NSS) receipt, analysis, and reporting. All procedures with nuclear safety implications were reviewed for accuracy and adequate detail to perform the analytical measurements safely, efficiently, and with the utmost quality. Laboratory personnel worked in a Deliberate Operating'' mode (a systematic process requiring continuous expert oversight during all phases of training, testing, and implementation) to initiate the upgrades. Thus, the effort to revise and review nuclear safety sample procedures involved a team comprised of a supervisor, chemist, and two technicians for each procedure. Each NSS procedure was upgraded to a Use Every Time'' (UET) procedure with sign-off steps to ensure compliance with each step for every nuclear safety sample analyzed. The upgrade program met and exceeded both the long and short term customer needs by improving measurement reliability, providing objective evidence of rigid adherence to program principles and requirements, and enhancing the system for independent verification of representative sampling from designated NCS points.

Boler-Melton, C.; Holland, M.K.

1991-01-01T23:59:59.000Z

344

SAPHIRE 8 Software Quality Assurance Oversight  

SciTech Connect (OSTI)

The software quality assurance oversight consists of updating and maintaining revision control of the SAPHIRE 8 quality assurance program documentation and of monitoring revision control of the SAPHIRE 8 source code. This report summarizes the oversight efforts through description of the revision control system (RCS) setup, operation and contents. Documents maintained under revision control include the Acceptance Test Plan (ATP), Configuration Management Plan, Quality Assurance Plan, Software Project Plan, Requirements Traceability Matrix (RTM), System Test Plan, SDP Interface Training Manual, and the SAPHIRE 8, 'New Features and Capabilities Overview'.

Kurt G. Vedros

2011-09-01T23:59:59.000Z

345

Department of Energy Technical Standards Procedures | Department...  

Broader source: Energy.gov (indexed) [DOE]

Department of Energy Technical Standards Procedures Department of Energy Technical Standards Procedures The following procedures should be used to write, revise, or maintain a DOE...

346

Federal Agency NEPA Procedures | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Federal Agency NEPA Procedures Federal Agency NEPA Procedures Each Federal agency is required to develop NEPA procedures that supplement the CEQ Regulations. Developed in...

347

Records Management Exit Procedures | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Exit Procedures Records Management Exit Procedures The purpose of this brochure is to provide records exit procedures for Federal and contractor employees who are departing on a...

348

Chapter 13 - Simplified Acquisition Procedures | Department of...  

Broader source: Energy.gov (indexed) [DOE]

13 - Simplified Acquisition Procedures Chapter 13 - Simplified Acquisition Procedures 13.1 - Purchase Card Policy and Operating Procedures 13.2PurchaseOrders0.pdf More Documents...

349

Ordering Procedures for Contract Audit Services | Department...  

Broader source: Energy.gov (indexed) [DOE]

Ordering Procedures for Contract Audit Services Ordering Procedures for Contract Audit Services Contract Audit Services Ordering Procedures for Contract Audit Services More...

350

An electronic procedure system for WSRC fuel material facility  

SciTech Connect (OSTI)

The production of naval fuel, like many production processes within the Westinghouse complex, depends very heavily on strict procedure compliance. Thus operators need to have quick access to procedures and they need to have some assurance that they are using the most current revision. This is often both difficult and time consuming on a production floor. In order to resolve some of these problems two members of the Naval Fuel Product Team are currently developing an electronic procedure system. It is the intent of the system to have workstations on the production floor. These workstations will be networked to a centralized computer used exclusively as a file server for holding the current revision of each procedure. By simply clicking a mouse on the appropriate icon, a user will be able to access any procedure required in his portion of the process. In this user friendly environment the operator can either read the procedure on the workstation screen or print a copy of the procedure at a nearby printer. Since it is often the case that a graphic is used in one procedure is also used in other procedures, we plan to store individual graphics separately from a given procedure. In this way when a graphic changes, only one correction needs to be made in order for that graphic to be automatically updated in every procedure in which it is used. In the future we plan to expand the system so that the operator will be able to enter procedure data into the procedure. We have plans for this to be a platform for both the Distributive Control and Nuclear Accountability Systems. Farther down the road we envision operating in a real-time environment were the workstation would be able to read data directly from equipment in the process. 14 figs.

Derr, S.M.; Sloan, C.W.

1989-01-01T23:59:59.000Z

351

Identifying Non-Federal Cooperating Agencies in Implementing the Procedural  

Broader source: Energy.gov (indexed) [DOE]

Identifying Non-Federal Cooperating Agencies in Implementing the Identifying Non-Federal Cooperating Agencies in Implementing the Procedural Requirements of NEPA Identifying Non-Federal Cooperating Agencies in Implementing the Procedural Requirements of NEPA The purpose of this Council on Environmental Quality Memorandum is to ensure that all federal and non-federal cooperating agencies are identified on the cover sheet of each Environmental Impact Statement (EIS) prepared by your agency. G-CEQ-IdentnonfedCooperatingAgencies.pdf More Documents & Publications Designation of Non-Federal Agencies as Cooperating Agencies Cooperating Agencies in Implementing the Procedural Requirements of the National Environmental Policy Act Reporting Cooperating Agencies in Implementing the Procedural Requirements of the National Environmental Policy Act

352

The Multi-Scale Mass Transfer Processes Controlling Natural Attenuation and Engineered Remediation: An IFC Focused on Hanford’s 300 Area Uranium Plume Quality Assurance Project Plan  

SciTech Connect (OSTI)

The purpose of the project is to conduct research at an Integrated Field-Scale Research Challenge Site in the Hanford Site 300 Area, CERCLA OU 300-FF-5 (Figure 1), to investigate multi-scale mass transfer processes associated with a subsurface uranium plume impacting both the vadose zone and groundwater. The project will investigate a series of science questions posed for research related to the effect of spatial heterogeneities, the importance of scale, coupled interactions between biogeochemical, hydrologic, and mass transfer processes, and measurements/approaches needed to characterize a mass-transfer dominated system. The research will be conducted by evaluating three (3) different hypotheses focused on multi-scale mass transfer processes in the vadose zone and groundwater, their influence on field-scale U(VI) biogeochemistry and transport, and their implications to natural systems and remediation. The project also includes goals to 1) provide relevant materials and field experimental opportunities for other ERSD researchers and 2) generate a lasting, accessible, and high-quality field experimental database that can be used by the scientific community for testing and validation of new conceptual and numerical models of subsurface reactive transport.

Fix, N. J.

2008-01-31T23:59:59.000Z

353

Stanford University HRPP Continuous Quality Improvement (CQI) Program  

E-Print Network [OSTI]

/13 Research Compliance Office STANFORD measures and improves, when necessary, compliance with organizational measures and improves, when necessary, the quality, effectiveness, and efficiency of the Human Research to assess compliance with organizational policies and procedures and applicable laws, regulations, codes

Puglisi, Joseph

354

Academic Quality Handbook Appendix 5.18a  

E-Print Network [OSTI]

Academic Quality Handbook Appendix 5.18a UNIVERSITY OF ABERDEEN POLICY AND PROCEDURES ON STUDENT or disagree with a CAS mark awarded. Academic judgement is a matter solely for the relevant School

Levi, Ran

355

Academic Quality Handbook Appendix 5.18a  

E-Print Network [OSTI]

1 Academic Quality Handbook Appendix 5.18a UNIVERSITY OF ABERDEEN POLICY AND PROCEDURES ON STUDENT exercised. For example, a student cannot appeal simply because they are unhappy or disagree with a CAS mark

Levi, Ran

356

Academic Quality Handbook Appendix 5.18a  

E-Print Network [OSTI]

1 Academic Quality Handbook Appendix 5.18a UNIVERSITY OF ABERDEEN POLICY AND PROCEDURES ON STUDENT, a student cannot appeal simply because they are unhappy or disagree with a CAS mark awarded. Academic

Levi, Ran

357

Procedures for Students seeking accommodations.  

E-Print Network [OSTI]

This document outlines the procedures to be followed by students seeking accommodations in the following mathematics courses during Fall and Spring ...

358

Does context matter in quality evaluation of mobile television?  

Science Journals Connector (OSTI)

Subjective quality evaluation is used to optimize the produced audiovisual quality from fundamental signal processing algorithms to consumer services. These studies typically follow the basic principles of controlled psychoperceptual experiments. However, ... Keywords: context, ecological validity, evaluation, mobile TV, mobile television, subjective quality, transmission quality

Satu Jumisko-Pyykkö; Miska M. Hannuksela

2008-09-01T23:59:59.000Z

359

Appendix C of the UF Chemical Hygiene Plan Standard Operating Procedures  

E-Print Network [OSTI]

1 Appendix C of the UF Chemical Hygiene Plan Standard Operating Procedures Principal Investigator of our emergency equipment: The following are the spill control and decontamination procedures: The following are the waste disposal procedures: #12;2 Appendix C of the UF Chemical Hygiene Plan Standard

Slatton, Clint

360

ACCESS CONTROL  

Broader source: Energy.gov (indexed) [DOE]

TERMS/DEFINITIONS FROM DOE M 470.4-7 TERMS/DEFINITIONS FROM DOE M 470.4-7 ACCESS CONTROL. The process of permitting access or denying access to information, facilities, nuclear materials, resources, or designated security areas. ACCESS CONTROL MEASURES. Hardware and software features, physical controls, operating procedures, administrative procedures, and various combinations of these designed to detect or prevent unauthorized access to classified information; special nuclear materials; Government property; automated information systems, facilities, or materials; or areas containing the above and to enforce use of these measures to protect Departmental security and property interests. CRITICAL PATH SCENARIO. An adversary-based scenario that is generated during the conduct of a vulnerability assessment and accounts for adversary tactics that

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Procedure for Planning and Conducting  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Lift Plan Procedure Lift Plan Procedure Stanford Synchrotron Radiation Laboratory Lead Author __________________________________ Date 07/13/2005___________ David A. Ernst Mechanical Service Group Approvals: __________________ Date _____________________ Matt Padilla SSRL Safety Officer __________________ Date _____________________ Robert Hettel Accelerator System Department Head __________________ Date _____________________ Piero Pianetta Beam Line System Department Head Hoist and Rigging Panel Member _______________________________________ Date ______________________

362

Fuel Station Procedure Applicability All  

E-Print Network [OSTI]

Fuel Station Procedure Applicability All Last Revised 11/20/12 Procedure Owner Andrew Grant agrant for the purchasing and distribution of fuel for vehicles owned by Bowling Green State University (BGSU). This centralization is important to ensure compliance for BGSU employees who use the centralized fuel station and fuel

Moore, Paul A.

363

LOCKOUT/TAGOUT Policy & Procedure  

E-Print Network [OSTI]

LOCKOUT/TAGOUT Policy & Procedure Office of Environmental Health and Safety 5425 Woodward, Suite This procedure establishes the Wayne State University requirements for the lockout of energy isolating devices that employee's duties include performing service or maintenance covered under this section. Lockout

Berdichevsky, Victor

364

Procedure to Measure Indoor Lighting Energy Performance  

SciTech Connect (OSTI)

This document provides standard definitions of performance metrics and methods to determine them for the energy performance of building interior lighting systems. It can be used for existing buildings and for proposed buildings. The primary users for whom these documents are intended are building energy analysts and technicians who design, install, and operate data acquisition systems, and who analyze and report building energy performance data. Typical results from the use of this procedure are the monthly and annual energy used for lighting, energy savings from occupancy or daylighting controls, and the percent of the total building energy use that is used by the lighting system. The document is not specifically intended for retrofit applications. However, it does complement Measurement and Verification protocols that do not provide detailed performance metrics or measurement procedures.

Deru, M.; Blair, N.; Torcellini, P.

2005-10-01T23:59:59.000Z

365

Safeguarding indoor air quality  

SciTech Connect (OSTI)

California has created and implemented the first state program devoted exclusively to the investigation of nonindustrial indoor air quality. The program is responsible for promoting and conducting research on the determining factors of healthful indoor environments and is structured to obtain information about emission sources, ventilation effects, indoor concentrations, human activity patterns, exposures, health risks, control measures and public policy options. Data are gathered by a variety of methods, including research conducted by staff members, review of the available scientific literature, participation in technical meetings, contractual agreements with outside agencies, cooperative research projects with other groups and consultation with experts. 23 references, 1 figure, 1 table.

Sexton, K.; Wesolowski, J.J.

1985-01-01T23:59:59.000Z

366

E-Print Network 3.0 - air quality implementation Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Commission on Environmental Quality, Saffett Tanrikulu Bay Area Air Quality Control District, Jon Pleim- EPA... for SIPs and air ... Source: Jacob, Daniel J. - School of...

367

E-Print Network 3.0 - air quality strategy Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Commission on Environmental Quality, Saffett Tanrikulu Bay Area Air Quality Control District, Jon Pleim- EPA... for SIPs and air ... Source: Jacob, Daniel J. - School of...

368

E-Print Network 3.0 - air quality research Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Commission on Environmental Quality, Saffett Tanrikulu Bay Area Air Quality Control District, Jon Pleim- EPA... for SIPs ... Source: Jacob, Daniel J. - School of...

369

Quality management system and accreditation of the in vivo monitoring laboratory at Karslruhe Institue of Technology  

Science Journals Connector (OSTI)

......Laboratory, Institute for Radiation Research, Karlsruhe Institute...Development Quality Control Radiation Monitoring methods standards Radiation Protection methods standards...Radiometry methods standards Safety Software Total Quality Management......

B. Breustedt; U. Mohr; N. Biegard; G. Cordes

2011-03-01T23:59:59.000Z

370

E-Print Network 3.0 - assessing health-related quality Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

trials in Summary: issues in assessing health-related quality of life of colorectal cancer patients in randomised controlled... , Molica S , Holzner B . Health-related quality...

371

Automatic Control Technology in the HVAC System  

Science Journals Connector (OSTI)

In the field of VAV air-conditioning system (Variable Air Volume, VAV) control theory and practical study, the paper analyzed the methods used by the China's VAV control procedures including Static Pressure Control, Variable Pressure Control and Total ...

Ren Tao; Gao Jingmin; Jia Wenwen

2009-01-01T23:59:59.000Z

372

Ionising Radiation emitters Spill Procedure Page 1 of 3 Version: 3.2, 5/02/2013  

E-Print Network [OSTI]

as necessary to reduce contamination close to background levels. For spills involving radioactive iodine, use.......................................................................................................3 1. Purpose and Scope Immediate control procedures for radioactive spillages of gamma Procedure Instructions In the Event of a Radioactive Spill in this Room Immediate control procedures

New South Wales, University of

373

FIELD TEST OF THE FLAME QUALITY INDICATOR  

SciTech Connect (OSTI)

The flame quality indicator concept was developed at BNL specifically to monitor the brightness of the flame in a small oil burner and to provide a ''call for service'' notification when the brightness has changed from its setpoint, either high or low. In prior development work BNL has explored the response of this system to operational upsets such as excess air changes, fouled atomizer nozzles, poor fuel quality, etc. Insight Technologies, Inc. and Honeywell, Inc. have licensed this technology from the U.S. Department of Energy and have been cooperating to develop product offerings which meet industry needs with an optimal combination of function and price. Honeywell has recently completed the development of the Flame Quality Monitor (FQM or Honeywell QS7100F). This is a small module which connects via a serial cable to the burners primary operating control. Primary advantages of this approach are simplicity, cost, and ease of installation. Call-for-service conditions are output in the form of front panel indicator lights and contact closure which can trigger a range of external communication options. Under this project a field test was conducted of the FQM in cooperation with service organizations in Virginia, Pennsylvania, New Jersey, New York, and Connecticut. At total of 83 field sites were included. At each site the FQM was installed in parallel with another embodiment of this concept--the Insight AFQI. The AFQI incorporates a modem and provides the ability to provide detailed information on the trends in the flame quality over the course of the two year test period. The test site population was comprised of 79.5% boilers, 13.7% warm air furnaces, and 6.8% water heaters. Nearly all were of residential size--with firing rates ranging from 0.6 gallons of oil per hour to 1.25. During the course of the test program the monitoring equipment successfully identified problems including: plugged fuel lines, fouled nozzles, collapsed combustion chambers, and poor fuel pump cut-off. Service organizations can use these early indications to reduce problems and service costs. There were also some ''call-for-service'' indications for which problems were not identified. The test program also showed that monitoring of the flame can provide information on burner run times and this can be used to estimate current oversize factors and to determine actual fuel usage, enabling more efficient fuel delivery procedures.

Andrew M. Rudin; Thomas Butcher; Henry Troost

2003-02-04T23:59:59.000Z

374

Building Technologies Office: Current Test Procedure Waivers  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Test Procedure Test Procedure Waivers to someone by E-mail Share Building Technologies Office: Current Test Procedure Waivers on Facebook Tweet about Building Technologies Office: Current Test Procedure Waivers on Twitter Bookmark Building Technologies Office: Current Test Procedure Waivers on Google Bookmark Building Technologies Office: Current Test Procedure Waivers on Delicious Rank Building Technologies Office: Current Test Procedure Waivers on Digg Find More places to share Building Technologies Office: Current Test Procedure Waivers on AddThis.com... About Standards & Test Procedures Implementation, Certification & Enforcement Rulemakings & Notices Current Rulemakings & Notices Test Procedure Waivers Recent Federal Register Notices How to Participate or Comment

375

Up-Stream Dissolved Oxygen TMDL Project Quality Assurance ProjectPlan  

SciTech Connect (OSTI)

A quality assurance project plan (QAPP) for the execution of an ecosystem level monitoring and research program examining algal ecology in highly impaired rivers. Procedures for executing both field and laboratory surface water quality and flow analysis are described. The procedures described here are compatible with the California Surface Water Ambient Monitoring program (SWAMP).

Stringfellow, William T.

2005-05-13T23:59:59.000Z

376

QualityAssurance&Testing  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Testing and Testing Manufacturing Technologies The Manufacturing Science & Technology Center provides customers with manufacturing quality requirements, testing standards and specifica- tions for new product designs, including the implementation of these requirements into final product acceptance complete with documenta- tion. Technical support and procedures are fur- nished for Interagency Product Acceptance. Capabilities * Will inspect printed circuit (PC) boards, wire wrap boards, boxes, chassis, cables, racks, systems, etc. * Work from sketches or formal drawings * Review drawings and requirements * Visual inspections for layout, markings, solder joints, components, mechanical assembly, general workmanship, safety * Point-to-point continuity checks

377

Speech quality in wireless systems  

Science Journals Connector (OSTI)

Modern wireless communication systems require a very sophisticated design from the electrical as well as from the acoustical point of view. Since the maximum of functionality needs to be integrated in designs—getting smaller with every new generation—not much space is left for the acoustical components. In addition such sets typically are used in noisy environments. In order to provide a minimum of speech quality a careful design of the acoustical components as well as of the according electrical components is required. Very often there is a strong interaction between those. The presentation will describe the typical types of signal processing and acoustical designs used in such sets and will give methodologies on how to assess the speech quality relevant parameters of such sets. Measurements for optimizing the acoustical design will be described. In addition system evaluation procedures for nonlinear and time?variant signal processing are discussed.

Hans Wilhelm Gierlich; Winfried Krebber; Frank Kettler

1999-01-01T23:59:59.000Z

378

NFRC Procedures for Applied Films  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Applied Films Applied Films Last update: 12/10/2013 07:29 PM NFRC now has a procedure for adding applied films to substrates in Optics5 and importing those applied film constructions into WINDOW5 to be used in a whole product calculation. The information presented below is provided to help simulators with this process. Feel free to contact us at WINDOWHelp@lbl.gov with questions or comments. NFRC Applied Film Procedure Applied Film Procedures (approved by NFRC) (PDF file) Approved Applied Film List (IGDB 33.0) (PDF file) NFRC Laminate Procedure Training Powerpoint with Examples (This Powerpoint presentation was used in the NFRC web based training sessions in December 2006 and January 2007) PowerPoint Presentation (PPT file) PowerPoint Presentation (PDF file) Help and Troubleshooting

379

29.01.03.M1.09 Information Resources Incident Management Page 1 of 3 STANDARD ADMINISTRATIVE PROCEDURE  

E-Print Network [OSTI]

, internet/intranet procedures, and acceptable use procedures. Definitions Information Resources (IR follow System Regulation 10.02.01, Control of Fraud, Waste and Abuse. 2.6 If there is a substantial

380

A high quality permanent-magnet wiggler for the Rocketdyne/Stanford infrared free electron laser  

Science Journals Connector (OSTI)

A high quality, variable gap, variable taper, permanent-magnet wiggler has been built for infrared free electron laser (FEL) experiments to be performed at the Stanford Photon Research Laboratory. The design and characterization procedure used to assemble the wiggler is discussed. A simulated annealing code was used to minimize field errors arising from variations in the individual magnets. The computed electron trajectories associated with the measured magnetic fields are presented for a range of different operating points of the wiggler. These plots indicate a very high quality field over a large range of different wiggler operating regimes. Resultant trajectory wander over the 2 m long wiggler for a 40 MeV electron at a wiggler gap corresponding to 3.3 kG was calculated to be less than 25 ?m. The ability to control trajectory wander and optical phase slip using the simulated annealing code suggests future extensions to extremely long wigglers.

Mark S. Curtin; Anup Bhowmik; Wayne A. McMullin; Stephen V. Benson; John M.J. Madey; Bruce A. Richman; Louis Vintro

1988-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

USEPA quality assurance auditor is scheduled for a visit: What can I expect  

SciTech Connect (OSTI)

Environmental studies involving data collection activities conducted by or for the United States Environmental Protection Agency (USEPA) are required to undergo a review of their data collection activities. This review is usually in the form of an independent quality assurance (QA) audit. Those studies involving open-path Fourier transform infrared (OP/FTIR) monitoring are also expected to meet this requirement. To help evaluate the effectiveness of QA programs designed for OP/FTIR studies, an audit questionnaire was developed. This questionnaire provides a meaningful tool in assessing the study`s compliance with Agency and laboratory QA requirements and currently accepted quality control (QC) procedures. This paper introduces this audit questionnaire and discusses the basis for its development.

Childers, L.O.

1995-12-31T23:59:59.000Z

382

Dyke quality assessment by remote sensing  

E-Print Network [OSTI]

1 RSDYK Dyke quality assessment by remote sensing and geological information Robert Hack Flood Solutions for smart flood control 15 Oct 2009 2Reeuwijk - Hack #12;2 RSDYKRSDYK Quality assessment of dykes from remote sensing in combination with l i l k l dgeological knowledge 15 Oct 2009 3Reeuwijk - Hack

Hack, Robert

383

International Awareness for Quality Seafoods: A Survey  

E-Print Network [OSTI]

International Awareness for Quality Seafoods: A Survey CARMINE GORGA and LOUIS J. RONSIVALLI be- ginnings, seafood quality control pro- grams throughout the world have shown varying degrees of seafood con- sumption and the growth of the seafood industry as a whole. This article is divided

384

Control of the rate of evaporation in protein crystallization by the `microbatch under oil' method  

Science Journals Connector (OSTI)

A procedure is presented for controlling the rate of evaporation during `microbatch under oil' protein crystallization.

Brumshtein, B.

2008-08-30T23:59:59.000Z

385

Graduate School of Journalism Interim Grievance Procedures  

E-Print Network [OSTI]

Graduate School of Journalism Interim Grievance Procedures Introduction The following procedures the Dean to conduct a hearing under the formal grievance procedures described in this statement. Those procedures, like the procedures of other schools, provide for a final appeal to the University Provost

Qian, Ning

386

Office of Quality Assurance  

Broader source: Energy.gov [DOE]

The Office of Quality Assurance establishes and maintains the quality assurance (QA) policies, requirements and guidance for the Department and serves as DOE's corporate resource to ensure that products and services meet or exceed the Department’s quality objectives.

387

Honeywell Modular Automation System Acceptance Test Procedure  

SciTech Connect (OSTI)

The purpose of this Acceptance Test Procedure (ATP) is to verify the operability of the three new furnaces as controlled by the new Honeywell Modular Automation System (MAS). The Honeywell MAS is being installed in PFP to control the three thermal stabilization furnaces in glovebox HA-211. The ATP provides instructions for testing the configuration of the Honeywell MAS at the Plutonium Finishing Plant(PFP). The test will be a field test of the analog inputs, analog outputs, and software interlocks. The interlock test will check the digital input and outputs. Field equipment will not be connected forth is test. Simulated signals will be used to test thermocouple, limit switch, and vacuum pump inputs to the PLUMAS.

STUBBS, A.M.

1999-09-21T23:59:59.000Z

388

Surface Water Quality Standards  

E-Print Network [OSTI]

SURFACE WATER QUALITY STANDARDS AAs part of the ongoing program to manage Texaswater quality, the Texas Commission onEnvironmental Quality (TCEQ) is currently review- ing the Texas Surface Water Quality Standards, including the standards... for contact recreation use. Preliminary public comment plus input from the Surface Water Quality Standards Advisory Work Group have provided guidance on options available for revising the standards, said Jim Davenport, leader of the TCEQ Water Quality...

Wythe, Kathy

2007-01-01T23:59:59.000Z

389

CHSP: HAZARD CONTROLS  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HYGIENE HYGIENE AND SAFETY PLAN CHSP SITE MAP HAZARD CONTROLS CONTROLS FOR HAZARDOUS MATERIALS arrow image WORK PRACTICE CONTROLS arrow image CHEMICAL STORAGE GUIDELINES DECOMISSIONING LAB AND SHOP SPACES SPECIFIC CONTROLS AND PROCEDURES arrow image EMERGENCY PROCEDURES AND EQUIPMENT arrow image APPENDICES arrow image FAQs QUESTIONS Search the CHSP: > Go spacer image EH&S Home PUB 3000 LBNL Home LBNL A-Z Index LBNL Search LBNL Phone Book Privacy & Security Notice spacer spacer image spacer image spacer image HAZARD CONTROLS This section discusses control procedures for limiting employee exposure to chemical hazards. Technical Areas Technical areas include laboratories, shops, workrooms, and similar areas where non-administrative activities are performed. For the purpose of the

390

Global Threat Reduction Initiative Fuel-Thermo-Physical Characterization Project Quality Assurance Plan  

SciTech Connect (OSTI)

The charter of the Fuel Thermo-Physical Characterization Project is to ready Pacific Northwest National Laboratory (PNNL) facilities and processes for the receipt of unirradiated and irradiated low enriched uranium (LEU) molybdenum (U-Mo) fuel element samples, and to perform analysis to support the Global Threat Reduction Initiative conversion program. PNNL’s support for the program will include the establishment of post-irradiation examination processes, including thermo-physical properties, unique to the U.S. Department of Energy laboratories. These processes will ultimately support the submission of the base fuel qualification (BFQ) to the U.S. Nuclear Regulatory Commission (NRC) and revisions to High Performance Research Reactor Safety Analysis Reports to enable conversion from highly enriched uranium to LEU fuel. This quality assurance plan (QAP) provides the quality assurance requirements and processes that support the NRC BFQ. This QAP is designed to be used by project staff, and prescribes the required management control elements that are to be met and how they are implemented. Additional controls are captured in Fuel Thermo-Physical Characterization Project plans, existing procedures, and procedures to be developed that provide supplemental information on how work is conducted on the project.

Pereira, Mario M.; Slonecker, Bruce D.

2012-06-01T23:59:59.000Z

391

Final Report Project Activity Task ORD-FY04-002 Nevada System of Higher Education Quality Assurance Program  

SciTech Connect (OSTI)

The principal purpose of DOE Cooperative Agreement DE-FC28-04RW12232 is to develop and continue providing the public and the U.S. Department of Energy’s (DOE) Office of Civilian Radioactive Waste Management (OCRWM) with an independently derived, unbiased body of scientific and engineering data concerning the study of Yucca Mountain as a potential high-level radioactive waste repository. Under this agreement, the Nevada System of Higher Education (NSHE), formerly the University and Community College System of Nevada (UCCSN), performs scientific or engineering research, and maintains and fosters collaborative working relationships between government and academic researchers. In performing these activities, the NSHE has already developed and implemented a Quality Assurance (QA) program, which was accepted by the DOE Office of Quality Assurance, under the previous Cooperative Agreement Number DE-FC28-98NV12081. The following describes the objectives of Project Activity 002 “Quality Assurance Program” under cooperative agreement DE-FC28-04RW12232. The objective of this QA program was to assure that data produced under the cooperative agreement met the OCRWM QA Requirements and Description (QARD) requirements for quality-affecting (Q) data. The QA Program was written to address specific QARD requirements historically identified and incorporated in Q activities to the degree appropriate for the nature, scope, and complexity of the activity. Additional QARD requirements were integrated into the program when required to complete a specific activity. NSHE QA staff developed a detailed matrix to address each QARD element, identifying the applicable requirements and specifying where each requirement is addressed in the QA program procedures, or identify requirements as “not applicable” to the QA program. Controlled documents were prepared in the form of QA procedures (QAPs) and implementing procedures (IPs). NSHE identified new QAPs and IPs when needed. NSHE PIs implemented the QA program and completed individual research project activities. PIs were also responsible for developing implementing procedures, conducting technical training, assuring that the QA program training was acquired by all task personnel, and participating in monitoring the QA program control for each individual research project activity. This project activity, which was an essential part of the program to enhance the collaborative ongoing research between the NSHE and ORD, was intended to support all quality-affecting activities funded during the five-year period of the cooperative agreement. However, the cooperative agreement was down-graded to non quality-affecting after 4 years.

Smiecinski, Amy; Keeler, Raymond; Bertoia, Julie; Mueller, Terry; Roosa, Morris; Roosa, Barbara

2008-03-07T23:59:59.000Z

392

Environmental Quality: Air (Louisiana)  

Broader source: Energy.gov [DOE]

The Department of Environmental Quality regulates air quality in Louisiana. The Department has an established a fee system for funding the monitoring, investigation and other activities required...

393

Quality Assurance Specialist  

Broader source: Energy.gov [DOE]

The selectee will serve as a Quality Assurance (QA) Specialist within the Department of Energy Idaho Operations Office (DOE-ID). The Quality Assurance Specialist (QAS) provides specialized...

394

Federal Agency NEPA Implementing Procedures  

Broader source: Energy.gov (indexed) [DOE]

Agency NEPA Implementing Procedures Agency NEPA Implementing Procedures Note: Some Departments' agencies have their own NEPA implementing procedures. To access Department-wide NEPA implementing procedures, click on the name of the Federal Department. To access NEPA implementing procedures for Department's agencies, click on the provided links. Department/ Agency: Division: Link: Department of Agriculture Agricultural Research Service http://www.ecfr.gov/cgi- in/text- idx?c=ecfr&SID=47c103e07fd64e933c7f74c 4b3c4ac9a&rgn=div5&view=text&node=7:6. 1 2 1 8&id 7 Animal and Plant Health Inspection Service http://www.ecfr.gov/cgi-bin/text- idx?c=ecfr&SID=47c103e07fd64e933c7f74c 4b3c4ac9a&rgn=div5&view=text&node=7:5. 1.1.1.21&idno=7 Farm Service Agency http://www.ecfr.gov/cgi-bin/text-

395

Data Quality of Quality Measurement Experiments  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Data Quality of Quality Measurement Experiments Data Quality of Quality Measurement Experiments S. Bottone and S. Moore Mission Research Corporation Santa Barbara, California Introduction Quality Measurement Experiments (QME) are a special class of Value-Added Products (VAP). QMEs add value to Atmospheric Radiation Measurement (ARM) Program datastreams by providing for continuous assessment of the quality of incoming data based on internal consistency checks, comparisons between independent similar measurements, or comparisons between measurements and modeled results. Like any datastream, QME datastreams need to be checked for data quality. For each QME, we analyze a representative sample of files from the ARM data archive to determine 'typical' values of the QME variables. We then design outlier tests, specific to each variable, to be applied to

396

POSTGRADUATE PROGRAMMES Procedures and Requirements  

E-Print Network [OSTI]

Engineering, Materials Science, Mechanical Engineering, Nuclear Engineering and Technology and Photonics Statistics), Mechanical Engineering, Nuclear Engineering and Technology, Photonics Science and Engineering and engineering manpower of the highest quality, to cater to the needs of industry, R & D organisations

Jagannatham, Aditya K.

397

UC Santa Barbara Policy and Procedure Implementing Procedures for the Whistleblower Policy  

E-Print Network [OSTI]

UC Santa Barbara Policy and Procedure Implementing Procedures for the Whistleblower Policy Contact: 8 Implementing Procedures for the Whistleblower Policy I. Purpose and Scope UC Santa Barbara's implementing procedure for the University of California Policy for Reporting and Investigating Allegations

Sideris, Thomas C.

398

DOE Technical Standards Program: Procedures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Department of Energy Technical Standards Procedures Department of Energy Technical Standards Procedures Office of Nuclear Safety The following procedures should be used to write, revise, or maintain a DOE technical standard. They are also used to convert a DOE technical standard to a non-government standard or to form a topical committee. Table of Contents (TSPP-00) Program Overview and Responsibilities (TSPP-01) Initiating DOE Technical Standards (TSPP-02) Use of Voluntary Consensus Standards and Interaction with Standards Development Organizations (TSPP-03) Developing DOE Technical Standard (TSPP-04) Coordination of Technical Standards (TSPP-05) - Draft In Concurrence Resolution - TSPP-06-2009 is the currently approved TSPP that addresses coordination of DOE Technical Standards. Approving and Issuing DOE Technical Standards (TSPP-06)

399

Building Technologies Office: Standards and Test Procedures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Standards and Test Standards and Test Procedures to someone by E-mail Share Building Technologies Office: Standards and Test Procedures on Facebook Tweet about Building Technologies Office: Standards and Test Procedures on Twitter Bookmark Building Technologies Office: Standards and Test Procedures on Google Bookmark Building Technologies Office: Standards and Test Procedures on Delicious Rank Building Technologies Office: Standards and Test Procedures on Digg Find More places to share Building Technologies Office: Standards and Test Procedures on AddThis.com... About Standards & Test Procedures Implementation, Certification & Enforcement Rulemakings & Notices Further Guidance ENERGY STAR® Popular Links Success Stories Previous Next Lighten Energy Loads with System Design. Learn More.

400

Administrative Billing Procedures (pbl/contracts)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

(Post-2006) Subscription Contracts IOUPublic Settlement Slice of the System Billing Procedures Firstgov Power Business Line (PBL) Administrative Billing Procedures This page has...

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

West Virginia University 1 Policies and Procedures  

E-Print Network [OSTI]

West Virginia University 1 Policies and Procedures In this Section: · Academic Integrity a Charge of Academic Dishonesty · Appeal Procedures for Cases Involving Academic Dishonesty Academic

Mohaghegh, Shahab

402

POLICY GUIDANCE MEMORANDUM #31 - Procedures for Regularizing...  

Broader source: Energy.gov (indexed) [DOE]

1 - Procedures for Regularizing Illegal Appointments POLICY GUIDANCE MEMORANDUM 31 - Procedures for Regularizing Illegal Appointments As part of the Department's ongoing effort to...

403

Postdoctoral Hiring Procedures | Argonne National Laboratory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hiring Procedures The Postdoctoral Office at DEP coordinates and facilitates the application, review, and hiring procedures for all postdoctoral candidates, following the...

404

Export Authorizations - Procedures | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Export Authorizations - Procedures Export Authorizations - Procedures Part II, Section 202(e) of the Federal Power Act (FPA) states that exports of electric energy should be...

405

Presidential Permits - Procedures | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Permits - Procedures Presidential Permits - Procedures Executive Order 12038 states that, before a Presidential permit may be issued, the action must be found to be consistent with...

406

Standards and Test Procedures | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Appliance & Equipment Standards Standards and Test Procedures Standards and Test Procedures The Department of Energy (DOE) establishes energy efficiency standards for certain...

407

SAFETY PROCEDURE SP-24 NATIONAL HIGH MAGNETIC  

E-Print Network [OSTI]

SAFETY PROCEDURE SP-24 NATIONAL HIGH MAGNETIC FIELD LABORATORY NHMFL FLORIDA STATE UNIVERSITY SAFETY PROCEDURE SP-24 VISITOR AND CONTRACTOR SAFETY DIRECTOR, ENVIRONMENTAL, HEALTH, SAFETY & SECURITY Angela Sutton

Weston, Ken

408

EERE Quality Control Workshop Final Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Co-Sponsored By: U.S. Department of Energy-Fuel Cell Technologies Office (FCTO), Solar Energy Technologies Office (SETO), Vehicle Technologies Office (VTO), Building...

409

EERE Quality Control Workshop Proceedings Released | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

College on August 15, 2014. | Energy Department file photo. Energy Department Trains Veterans in Advanced Manufacturing New Sensor Network Technology Increases...

410

EERE Quality Control Workshop Final Report  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

CO 80401 Co-Sponsored By: U.S. Department of Energy-Fuel Cell Technologies Office (FCTO), Solar Energy Technologies Office (SETO), Vehicle Technologies Office (VTO), Building...

411

Software Quality Assurance Control of Existing Systems  

Office of Environmental Management (EM)

SA Maysa Peterson LA Uma Reddi LL Edward Russell, Chair LL Leslie Schaffer PXAAO Nancy Smith SR Robert Smith INEEL Nancy Storch LL Debby Tate ANL-W Preface The current version of...

412

Wood Quality: The Effects  

E-Print Network [OSTI]

Wood Quality: The Effects of Planting Density and Thinning Eini C. Lowell PNW Research Station wood quality? By volume, characteristic, product? #12;http://jilldenton.files.wordpress.com/2007, faster #12;What is it that defines wood quality?What is it that defines wood quality? Density: earlywood

413

Track 9: Quality Assurance  

Broader source: Energy.gov [DOE]

ISM Workshop Presentations Knoxville Convention Center, Knoxville, TN August 2009 Track 9: Quality Assurance

414

Collector substystem heliostat targeting verification: Test Procedure 116  

SciTech Connect (OSTI)

The objectives of this test procedure are: (1) to demonstrate that the correct heliostat targeting data for the receiver has been incorporated into the Heliostat Array Controllers (HAC) software by visually observing heliostat beams on the receiver; (2) to demonstrate that the HAC Graphics CRT displays the correct aim-point array and corresponding x, y and z target values selected; and (3) to demonstrate the HAC capability to select, control and display up to 20 sets of aimpoint tracking arrays.

Rose, G.R.

1981-08-10T23:59:59.000Z

415

Safe Operating Procedure LOCKOUT/TAGOUT FOR MACHINES & EQUIPMENT  

E-Print Network [OSTI]

Safe Operating Procedure (5/11) LOCKOUT/TAGOUT FOR MACHINES & EQUIPMENT: TRAINING AND INSPECTIONS during maintenance and repair operations. In these situations, a Lockout/Tagout (LO/TO) program must "Control of Hazardous Energy: Lockout/Tagout (LO/TO) for Machines and Equipment." This course is available

Farritor, Shane

416

EV America Skid Test Procedure  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 3 Revision 1 Effective June 2008 Battery Capacity and Depth of Discharge Test Prepared by Electric Transportation Applications Prepared by: _______________________________ Date:__________ Garrett P. Beauregard Approved by: ______________________________________________ Date: _______________ Donald B. Karner Procedure ETA-GTP003 Revision 1 2 Table of Contents 1 Objective ..................................................................................................................... 3 2 Purpose........................................................................................................................ 3 3 Documentation............................................................................................................

417

EV America Skid Test Procedure  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2 2 Revision 1 Effective June 2008 Traction System Test Prepared by Electric Transportation Applications Prepared by: _______________________________ Date:__________ Garrett P. Beauregard Approved by: ______________________________________________ Date: _______________ Donald B. Karner Procedure ETA-GTP002 Revision 1 2 Table of Contents 1 Objective ..................................................................................................................... 3 2 Purpose........................................................................................................................ 3 3 Documentation............................................................................................................

418

EV America Skid Test Procedure  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

4 4 Revision 1 Effective June 2008 Electromagnetic Interference and Susceptibility Test Prepared by Electric Transportation Applications Prepared by: _______________________________ Date:__________ Garrett P. Beauregard Approved by: ______________________________________________ Date: _______________ Donald B. Karner Procedure ETA-GTP004 Revision 1 2 Table of Contents 1 Objective ..................................................................................................................... 3 2 Purpose........................................................................................................................ 3 3 Documentation............................................................................................................

419

Cooperative Education Detailed Operational Procedures  

E-Print Network [OSTI]

credits of Cooperative education for one of the required elective courses in the ME programME 3990 Cooperative Education Detailed Operational Procedures Overview Cooperative education and Aeronautical Engineering faculty. Cooperative education is not a required component of the ME program

de Doncker, Elise

420

EMISSIONS TO AIR OPERATIONAL PROCEDURE  

E-Print Network [OSTI]

EMISSIONS TO AIR OPERATIONAL PROCEDURE Swansea University Estates Services Singleton Park Swansea to Air Department: Estates and Facilities Site: All Author: Ambreen Jahangir Approved by: Mark Durdin PURPOSE: To minimise emissions and discharges to air from boilers, fume cupboards, air conditioning

Harman, Neal.A.

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Software Synthesis Procedures Viktor Kuncak  

E-Print Network [OSTI]

Software Synthesis Procedures Viktor Kuncak LARA, I&C Swiss Federal Institute of Technology (EPFL Institute of Technology (EPFL) Lausanne, Switzerland philippe.suter@epfl.ch ABSTRACT Automated synthesis. To integrate synthesis into programming languages, software synthesis algorithms should behave in a predictable

Kuncak, Viktor

422

Modern control strategies for vacuum arc remelting of segregation sensitive alloys  

SciTech Connect (OSTI)

There are several process variables which are crucial to the control of vacuum arc remelting of segregation sensitive alloys. These are: electrode gap, melt rate, cooling rate, furnace annulus, furnace atmosphere and electrode quality (i.e. cleanliness and integrity). Of these variables, active, closed loop control is usually applied only to electrode gap. Other variables are controlled by controlling furnace operational parameters to preset schedules (e.g. melting current is ramped or held constant to control melt rate in an open loop fashion), through proper maintenance and calibration of equipment (e.g. to ensure proper cooling water and gas flow rates, or to accomplish an acceptable vacuum leak rate), through proper practice of procedures, and by maintaining electrode quality control. Electrode gap control is accomplished by controlling an electrode gap indicator such as drip-short frequency (or period) to a specified set-point. This type of control, though often adequate, ignores information available from other electrode gap indicators and is susceptible to upsets. A multiple input electrode gap controller is described which uses optimal estimation techniques to address this problem.

Williamson, R.L.; Schlienger, M.E. [Sandia National Labs., Albuquerque, NM (United States); Hysinger, C.L.; Beaman, J.J. [Univ. of Texas, Austin, TX (United States)

1997-06-01T23:59:59.000Z

423

RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY  

E-Print Network [OSTI]

RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY UC Davis-Caltrans Air Avenue Davis, CA 95616 Prepared for The California Department of Transportation Mike Brady, Air Quality control measure. #12;RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY

Levinson, David M.

424

Air Quality: Acronym List Department: Chemical and General Safety  

E-Print Network [OSTI]

hazard analysis AQPM air quality program manager ARP accidental release prevention ATCM air toxic control Standard NESHAPs National Emissions Standards for Hazardous Air Pollutants NOx oxides of nitrogen NPOC nonAir Quality: Acronym List Department: Chemical and General Safety Program: Air Quality Owner

Wechsler, Risa H.

425

Factors affecting water quality in Cherokee Reservoir  

SciTech Connect (OSTI)

The purpose was to: (1) define reservoir problems related to water quality conditions; (2) identify the probable causes of these problems; and (3) recommend procedures for achieving needed reservoir water quality improvements. This report presents the project findings to date and suggests steps for upgrading the quality of Cherokee Reservoir. Section II presents background information on the characteristics of the basin, the reservoir, and the beneficial uses of the reservoir. Section III identifies the impacts of existing reservoir water quality on uses of the reservoir for water supply, fishery resources, recreation, and waste assimilation. Section IV presents an assessment of cause-effect relationships. The factors affecting water quality addressed in Section IV are: (1) reservoir thermal stratification and hydrodynamics; (2) dissolved oxygen depletion; (3) eutrophication; (4) toxic substances; and (5) reservoir fisheries. Section V presents a preliminary evaluation of alternatives for improving the quality of Cherokee Reservoir. Section VI presents preliminary conclusions and recommendations for developing and implementing a reservoir water quality management plan. 7 references, 22 figures, 21 tables.

Iwanski, M.L.; Higgins, J.M.; Kim, B.R.; Young, R.C.

1980-07-01T23:59:59.000Z

426

Policies, Procedures and Guidelines Complete Policy Title  

E-Print Network [OSTI]

Policies, Procedures and Guidelines Complete Policy Title: Procedures for Faculty Appeal Tribunals are used in these procedures: 1. `Appellant' means a faculty member who is entitled to appeal a tenure, within the Policy, Section IV, clauses 6(a) and 6(b). II Documents Governing Appeal Procedures

Hitchcock, Adam P.

427

Past DOE Technical Standards Program Procedures  

Broader source: Energy.gov [DOE]

Review past procedures used to write, revise, or maintain a Department of Energy (DOE) technical standard.

428

PUBLIC INTEREST DISCLOSURE (PID) POLICY AND PROCEDURES  

E-Print Network [OSTI]

i PUBLIC INTEREST DISCLOSURE (PID) POLICY AND PROCEDURES #12;PUBLIC INTEREST DISCLOSURE POLICY AND PROCEDURES 2 Contents 1. AUTHORISATION OF PROCEDURES 3 2. INTRODUCTION 3 2.1. Statement of commitment 3 2.2. Relationship to other Bureau policies 4 2.3. Application of procedures 4 3. RESPONSIBILITIES AND OBLIGATIONS 4

Greenslade, Diana

429

Policies, Procedures and Guidelines Complete Policy Title  

E-Print Network [OSTI]

Policies, Procedures and Guidelines Complete Policy Title: Faculty General Grievance Procedure. OBJECTIVE This Procedure is designed to provide McMaster faculty members with prompt and impartial by existing, specific review procedures. It is intended to facilitate and promote informal resolution

Haykin, Simon

430

Policies, Procedures and Guidelines Complete Policy Title  

E-Print Network [OSTI]

Policies, Procedures and Guidelines Complete Policy Title: Procedures for University Reviews copy held by the policy owner, the written copy prevails. #12;Procedures for University Reviews of Academic Departments April 28, 2005 1 Procedures for University Reviews of Academic Departments1 I

Haykin, Simon

431

Division of Human Resources University Grievance Procedures  

E-Print Network [OSTI]

Division of Human Resources University Grievance Procedures Employee Relations/ USF System Grievance Procedure Questions: (813) 974-2970 Rev. 12/2012 This procedure applies to Administration, Staff in this procedure are expressed in calendar days. If a deadline falls on a Saturday, Sunday or holiday, an action

Meyers, Steven D.

432

CSP Policies & Procedures Process for Grade Appeals  

E-Print Network [OSTI]

CSP Policies & Procedures Process for Grade Appeals Grade Appeals ­ Generally speaking, once grades

Leistikow, Bruce N.

433

Ris-R-1263(EN) Procedures for Determination of  

E-Print Network [OSTI]

Plutonium procedure for seaweed 9 Plutonium procedure for 1-2 g sediment or soil 10 Americium procedure

434

Urban Air Quality Management: Detecting and Improving Indoor Ambient Air Quality  

Science Journals Connector (OSTI)

Current air pollution management and air quality control are primarily focused on outdoor and ... which act as public spaces, contaminated indoor air could be public health hazards. In Singapore ... spend a subst...

T. L. Tan; Gissella B. Lebron

2011-01-01T23:59:59.000Z

435

Digital Control for Automation  

Science Journals Connector (OSTI)

GREATER YIELDS OF BETTER QUALITY PRODUCTS at reduced costs: That's one way to look at automations goal. And among instruments for automation are data reduction systems (others: continuous process analyzers, computer elements, and control mechanisms). ...

1956-04-02T23:59:59.000Z

436

FAQS Qualification Card - Quality Assurance | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Qualification Card - Quality Assurance Qualification Card - Quality Assurance FAQS Qualification Card - Quality Assurance A key element for the Department's Technical Qualification Programs is a set of common Functional Area Qualification Standards (FAQS) and associated Job Task Analyses (JTA). These standards are developed for various functional areas of responsibility in the Department, including oversight of safety management programs identified as hazard controls in Documented Safety Analyses (DSA). For each functional area, the FAQS identify the minimum technical competencies and supporting knowledge and skills for a typical qualified individual working in the area. FAQC-QualityAssurance.docx Description Quality Assurance Qualification Card More Documents & Publications FAQS Gap Analysis Qualification Card - Quality Assurance

437

Radiation Safety Policy and Procedures Committee  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

RSPPC Meeting Minutes APS only RSPPC Meeting Minutes APS only Radiation Safety Policy and Procedures Committee Charter 1. Purpose The committee reviews functional changes to the Access Control Interlock System (ACIS) and Personnel Protection System (PSS) used to provide personnel protection and area exclusion related to APS accelerators, storage ring and other radiation handling areas. The RSPP Committee advises APS management on radiation safety matters. At the request of APS Management the committee reviews projects, recommends radiation safety policy, and evaluates accident investigation conclusions. 2. Membership Members are appointed by the APS Division Directors and APS Director for their knowledge and background in Interlock Systems, Radiation Safety, Accelerator Operations and Work on the Experiment Floor.

438

International Energy Agency design tool evaluation procedure  

SciTech Connect (OSTI)

Detailed state-of-the-art building energy simulation models from nations participating in International Energy Agency (IEA) Task VIII are used to develop a quantitative procedure to evaluate more simplified design tools. Simulations are performed with the detailed models on a series of cases that progress systematically from the extremely simple to the relatively realistic. Output values for the cases, such as annual loads, annual maximum and minimum temperatures, and peak loads, are used to set target ranges with which the results from more simplified design tools can be compared. The more realistic cases, although geometrically simple, test the ability of the design tools to model such combined effects as thermal mass, direct gain windows, overhangs, internally generated heat, and dead-band and set-back thermostat control strategies. 5 refs., 9 figs., 4 tabs.

Judkoff, R.; Barakat, S.; Bloomfield, D.; Poel, B.; Stricker, R.; van Haaster, P.; Wortman, D.

1988-07-01T23:59:59.000Z

439

A robust control strategy for combining DCV control with economizer control  

Science Journals Connector (OSTI)

Combining demand controlled ventilation (DCV) control and economizer control achieves acceptable and even better indoor air quality with minimum coil energy consumption. The control instability during the transition processes between different control modes are among the major difficulties faced when utilizing economizer control and when combining DCV control with economizer control in applications. A robust control strategy, using “freezing”, gain scheduling, integral term reset and feedback transition control for different transition processes, is developed for addressing these problems. They are evaluated on an air handling unit (AHU) using various simulation tests. The test results demonstrate that the robust control strategy allows stable and robust AHU control.

Shengwei Wang; Xinhua Xu

2002-01-01T23:59:59.000Z

440

CBFWA Wildlife Habitat Evaluation Procedures (HEP)CBFWA Wildlife Habitat Evaluation Procedures (HEP) (2006(2006--006006--00)00)  

E-Print Network [OSTI]

CBFWA Wildlife Habitat Evaluation Procedures (HEP)CBFWA Wildlife Habitat Evaluation Procedures (HEP 101HEP 101 Habitat Evaluation Procedures (HEP) developed byHabitat Evaluation Procedures (HEP

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

History of noise quality in the automotive industry  

Science Journals Connector (OSTI)

This paper will present a brief look at the emerging philosophy of sound quality as viewed from within the automotive engineering community. A few examples of the concepts of sound quality will be discussed focusing on their relevance to noise control in vehicles. The paper will be primarily historical in content relating how the ideas of sound quality came to be recognized as an important factor in noise control for automobiles.

Earl Geddes

1990-01-01T23:59:59.000Z

442

Assessment of geothermal development in the Imperial Valley of California. Volume 2. Environmental control technology  

SciTech Connect (OSTI)

Environmental control technologies are essential elements to be included in the overall design of Imperial Valley geothermal power systems. Environmental controls applicable to abatement of hydrogen sulfide emissions, cooling tower drift, noise, liquid and solid wastes, and induced subsidence and seismicity are assessed here. For optimum abatement of H{sub 2}S under a variety of plant operating conditions, removal of H{sub 2}S upstream of the steam turbine is recommended. The environmental impact of cooling tower drift will be closely tied to the quality of cooling water supplies. Conventional noise abatement procedures can be applied and no special research and development are needed. Injection technology constitutes the primary and most essential environmental control and liquid waste disposal technology for Imperial Velley geothermal operations. Subsurface injection of fluids is the primary control for managing induced subsidence. Careful maintenance of injection pressure is expected to control induced seismicity. (MHR)

Morris, W.; Hill, J. (eds.)

1980-07-01T23:59:59.000Z

443

OLYMPIC AIR QUALITY QUESTIONABLE  

Science Journals Connector (OSTI)

OLYMPIC AIR QUALITY QUESTIONABLE ... Athletes GOING FOR GOLD worry about Beijing’s air ... Atmospheric chemists say the air quality during the Beijing Games literally rests on which direction the winds blow. ...

RACHEL PETKEWICH

2008-07-28T23:59:59.000Z

444

Quality Assurance Program  

Broader source: Energy.gov [DOE]

Formal EM policy on the use of the corporate Quality Assurance Program (EM-QA-001 Rev. 1) to ensure all EM projects utilize a consistent quality assurance approach.

445

Active Aerodynamic Blade Distributed Flap Control Design Procedure  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Wind Energy Conference, Marseille, France, 16-19 March, 2009 I. Introduction Wind turbines are large, complex dynamically flexible structures that operate in turbulent and...

446

10 CFR Part 1021 National Environmental Policy Act Implementing Procedures  

Broader source: Energy.gov (indexed) [DOE]

21 21 Tuesday July 9, 1996 Part IV Department of Energy 10 CFR Part 1021 National Environmental Policy Act Implementing Procedures; Final Rule 36222 Federal Register / Vol. 61, No. 132 / Tuesday, July 9, 1996 / Rules and Regulations DEPARTMENT OF ENERGY 10 CFR Part 1021 RIN 1901-AA67 National Environmental Policy Act Implementing Procedures AGENCY: Department of Energy. ACTION: Final rule. SUMMARY: The Department of Energy (DOE) is amending its existing regulations governing compliance with the National Environmental Policy Act (NEPA). The amendments incorporate changes that improve DOE's efficiency in implementing NEPA requirements by reducing costs and preparation time while maintaining quality, consistent with the DOE Secretarial Policy Statement on NEPA issued in June 1994.

447

DOE NEPA Implementing Procedures: Final Rule (61 Fed Reg 36222) |  

Broader source: Energy.gov (indexed) [DOE]

61 Fed Reg 36222) 61 Fed Reg 36222) DOE NEPA Implementing Procedures: Final Rule (61 Fed Reg 36222) DOE amended its existing regulations governing compliance with the National Environmental Policy Act (NEPA). The amendments incorporate changes that improve DOE's efficiency in implementing NEPA requirements by reducing costs and preparation time while maintaining quality, consistent with the DOE Secretarial Policy Statement on NEPA issued in June 1994. These amendments also incorporate changes necessary to conform to recent changes in DOE's missions, programs, and policies that have evolved in response to changing national priorities since the current regulations were issued in 1992. 61 Fed Reg 36222: DOE NEPA Implementing Procedures-Final Rule More Documents & Publications

448

Use of line search in the Luus-Jaakola optimization procedure  

Science Journals Connector (OSTI)

A significant improvement in the rate of convergence of the Luus-Jaakola (LJ) optimization procedure is achieved by incorporating a simple line search. The line search is used to determine the best centre point after every pass, consisting of a number ... Keywords: LJ optimization procedure, line search, model reduction, optimal control, parameter estimation

Rein Luus

2007-07-01T23:59:59.000Z

449

University of Colorado Indoor Air Quality Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Image Courtesy of Ohio Image Courtesy of Ohio State University INDOOR AIR QUALITY Design Goals Design Goals Design Goals Design Goals Integrate technologically and economically innovative, low-energy strategies Minimize occupant distraction User-friendly controls Minimize pollutant sources Bio Bio Bio Bio- - - -S S S S ( ( ( (h h h h) ) ) ) ip ip ip ip indoor air quality features indoor air quality features indoor air quality features indoor air quality features Mechanical Systems Energy Recovery Ventilator Exhaust Fans Heating And Cooling Systems Passive Ventilation Low VOC materials Each of these features is described in more detail below. Mechanical Systems Energy Recovery Ventilator Knowing that our home has a tight envelope, due to our Bio-SIP construction, we needed to use mechanical ventilation to ensure suitable indoor air

450

EO 11514: Protection and Enhancement of Environmental Quality | Department  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

1514: Protection and Enhancement of Environmental Quality 1514: Protection and Enhancement of Environmental Quality EO 11514: Protection and Enhancement of Environmental Quality The Federal Government shall provide leadership in protecting and enhancing the quality of the Nation's environment to sustain and enrich human life. Federal agencies shall initiate measures needed to direct their policies, plans and programs so as to meet national environmental goals. The Council on Environmental Quality, through the Chairman, shall advise and assist the President in leading this national effort. EO 11514: Protection and Enhancement of Environmental Quality More Documents & Publications Regulations for Implementing the Procedural Provisions of NEPA The National Environmental Policy Act of 1969 Executive Order 11990-Protection Of Wetlands

451

Department of Energy Information Quality Guidelines | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

About this site » Department of Energy Information Quality About this site » Department of Energy Information Quality Guidelines Department of Energy Information Quality Guidelines Information Quality The Department of Energy's Information Quality Guidelines are developed in accordance with Section 515, Treasury and General Government Appropriations Act (Pub.L. 106-554). The law directed the Office of Management and Budget (OMB) to issue government-wide guidelines that "provide policy and procedural guidance to Federal Agencies for ensuring and maximizing the quality, objectivity, utility, and integrity of information (including statistical information) disseminated by Federal Agencies." OMB guidelines, published in the Federal Register on February 22, 2002 (67 FR 8452), direct agencies to issue their own implementing

452

Procedures for Preparing the Research Project Proposal (Revised: March 5, 2010) 1 PROCEDURES FOR A PROJECT  

E-Print Network [OSTI]

Procedures for Preparing the Research Project Proposal (Revised: March 5, 2010) 1 PROCEDURES FOR A PROJECT: for the Master of Science in Human-Computer Interaction, IN 46202 Indiana University - Purdue University, Indianapolis (IUPUI) #12;Procedures for Preparing

Zhou, Yaoqi

453

Control of electrostatic damage to electronic circuits  

SciTech Connect (OSTI)

Static is caused by the flow of materials and people within an environment. The static voltages generated by these movements can degrade or destroy many solid state devices currently being used in sophisticated electronic equipment. Discharge of static voltages through these sensitive devices during assembly operations can lead to a nonfunctional assembly fabricated from parts which previously were acceptable or to later failure of an assembly which was functional after fabrication. Sources of electrostatic charges, equipment and methods for minimizing the generation of electrostatic voltages during the production, assembly and packaging of solid state electronic equipment, and the sensitivity of solid state devices to electrostatic damage are discussed. It is concluded that static awareness is the key to an effective electrostatic damage (ESD) control program, and that production facilities must incorporate electrostatic protection facilities, materials, and processes so that workers can concentrate on producing a high-quality product without having to be overly concerned about ESD procedures. (LCL)

Kirk, W.J. Jr.

1980-03-01T23:59:59.000Z

454

UC Santa Barbara Academic Review Procedures  

E-Print Network [OSTI]

-Assessment .............................................. 5 D. Departmental Development Plan ........................................... 9 V. External Review plan; procedures for the selection of the External Review Committee (ERC); and guidelines for the ERCUC Santa Barbara Academic Review Procedures TABLE OF CONTENTS I. Purpose

Cappello, Peter

455

POLICY: A:VPFA # / Purchasing Policy PROCEDURES  

E-Print Network [OSTI]

POLICY: A:VPFA # / Purchasing Policy PROCEDURES: APPENDIX: Approved: April 1, 2013 Revised: Cross References: Purchasing Policy Capital Projects and Renovations Policy Conflict of Interest Policy Sustainability Policy Green Procurement Policy 1 of 9 PROCEDURES: Purchasing Policy AUTHORITY: University

Martin, Jeff

456

Current Test Procedure Waivers | Department of Energy  

Energy Savers [EERE]

Current Test Procedure Waivers Current Test Procedure Waivers The U.S. Department of Energy's (DOE) regulations for covered products permit a person to seek a waiver, or an interim...

457

Automated Operating Procedures for Transfer Limits  

E-Print Network [OSTI]

Automated Operating Procedures for Transfer Limits Final Project Report Power Systems Engineering · Illinois · Iowa State · Texas A&M · Washington State · Wisconsin Automated Operating Procedures

458

ADMINISTRATION AND FINANCE POLICIES AND PROCEDURES  

E-Print Network [OSTI]

ADMINISTRATION AND FINANCE POLICIES AND PROCEDURES Chapter 23 LEGAL PROCEDURES Approved by President: 9/3/03 23-1 TABLE OF CONTENTS 23.01 OVERVIEW.............................................................................................................................2 23.01.1 CURRENT POLICY

Rusu, Adrian

459

Delegation Procedures - DOE Directives, Delegations, and Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy's primary means of establishing policies, requirements, responsibilities, and procedures for Departmental elements and contractors. Directives Program Management Camille...

460

PROCEDURES and INSTRUCTIONS for SUBMITTING FINAL ...  

E-Print Network [OSTI]

Apr 16, 2010 ... PROCEDURES and INSTRUCTIONS for SUBMITTING FINAL GRADES. Please view rather than print this information. A version without ...

saerens

2010-04-16T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Cushioned centrifugation of stallion semen: factors impacting equine sperm recovery rate and quality  

E-Print Network [OSTI]

Centrifugation of stallion semen is an integral part of the cryopreservation procedure, primarily allowing for the concentration of sperm and removal of seminal plasma. In addition, centrifugation is required for maximizing spermatozoal quality...

Waite, Jessica Arlene

2008-10-10T23:59:59.000Z

462

Cushioned centrifugation of stallion semen: factors impacting equine sperm recovery rate and quality  

E-Print Network [OSTI]

Centrifugation of stallion semen is an integral part of the cryopreservation procedure, primarily allowing for the concentration of sperm and removal of seminal plasma. In addition, centrifugation is required for maximizing spermatozoal quality...

Waite, Jessica Arlene

2009-05-15T23:59:59.000Z

463

Remote quality monitoring in the banana chain  

Science Journals Connector (OSTI)

...bypassed the warehouse handling and directly transported...chain for bananas as applied in our field tests...prioritized for port handling. Palletloads which...development and monitoring technologies have to go hand...analyser; Control in applied Physiology (CP...i) Experimental procedure for banana storage...

2014-01-01T23:59:59.000Z

464

Faculty Code Chapter 28 Adjudication Filing Procedures  

E-Print Network [OSTI]

Faculty Code Chapter 28 Adjudication Filing Procedures Secretary of the Faculty 10/2014 #12;Page 1 |Adjudication Introduction| Chapter 28 of the Faculty Code sets forth the adjudicative procedures to be used resolution procedures are available at any time during the resolution process, including the time period

Van Volkenburgh, Elizabeth

465

Dartmouth College Employment Policies and Procedures Manual  

E-Print Network [OSTI]

Dartmouth College Employment Policies and Procedures Manual Policy last updated: April 25, 2008 Grievance Procedure, Equal Opportunity Applies to: All employees Policy Statement: Dartmouth College of the Equal Opportunity Policy may bring a complaint under the Equal Opportunity Grievance Procedure. In some

Myers, Lawrence C.

466

PROCEDURES FOR THE SEARCH, APPOINTMENT, OR REAPPOINTMENT  

E-Print Network [OSTI]

1 PROCEDURES FOR THE SEARCH, APPOINTMENT, OR REAPPOINTMENT OF THE PRESIDENT AND VICE- CHANCELLOR of Senate establish procedures for the recommendation and selection of the President and shall subsequently appoint the President. The following procedures determine the method by which the Board of Governors

Victoria, University of

467

UNIVERSITY OF FLORIDA RULES AND PROCEDURES  

E-Print Network [OSTI]

UNIVERSITY OF FLORIDA RULES AND PROCEDURES OF THE STUDENT SENATE ____________________________________________________________ Issued by the Office of the Student Senate Special Committee on Rules and Procedures October 2008 Amended through February, 2014 #12;#12;RULES AND PROCEDURES OF THE STUDENT SENATE TABLE OF CONTENTS

Roy, Subrata

468

Competency Patient Care Sub Domain Procedures  

E-Print Network [OSTI]

Competency Patient Care Sub Domain Procedures Learning Objective Understands informed consent and performs uncomplicated procedures on patients or in simulation Milestones Year I Year II Year III Year IV Mid End Mid End Mid End Mid End · Defines elements of informed consent for procedures · Explains

Leistikow, Bruce N.

469

Procedures and Standards for Residential Ventilation System  

E-Print Network [OSTI]

1 Procedures and Standards for Residential Ventilation System Commissioning: An Annotated, commissioning, procedures, standards, ASHRAE 62.2 Please use the following citation for this report: Stratton, J.C. and C.P. Wray. 2013. Procedures and Standards for Residential Ventilation System Commissioning

470

UCSD Implementing Procedures 36/Classification of Positions  

E-Print Network [OSTI]

UCSD Implementing Procedures (HR-S-1) 36/Classification of Positions I. REFERENCES AND RELATED POLICIES A. UCSD Implementing Procedures 20 ­ Recruitment B. UC PPSM 36 - Classification of Positions C shall be obtained prior to any commitment to the concerned individual. III. PROCEDURES A. New

Tsien, Roger Y.

471

Standards and Procedures for Promotion and Tenure  

E-Print Network [OSTI]

Appendix C Standards and Procedures for Promotion and Tenure I. Preamble This document sets forth standards and procedures for faculty promotions and appointments to tenure. These standards and procedures by university needs, plans, and resources. II. Standards The criteria outlined below are, of necessity

Heller, Barbara

472

DNFSB 2002-1 Software Quality Assurance Improvement Plan Commitment 4.2.1.2: Safety Quality Assurance Plan and Criteria for the Safety Analysis Toolbox Codes  

Broader source: Energy.gov (indexed) [DOE]

2-Criteria 2-Criteria Defense Nuclear Facilities Safety Board Recommendation 2002-1 Software Quality Assurance Improvement Plan Commitment 4.2.1.2: Software Quality Assurance Plan and Criteria for the Safety Analysis Toolbox Codes U.S. Department of Energy Office of Environment, Safety and Health 1000 Independence Ave., S.W. Washington, DC 20585-2040 November 2003 Software Quality Assurance Criteria for Safety Analysis Codes November 2003 INTENTIONALLY BLANK ii Software Quality Assurance Criteria for Safety Analysis Codes November 2003 FOREWORD This document discusses the Software Quality Assurance plan, and criteria and implementation procedures to be used to evaluate designated, safety-related computer software for the

473

Procedures for Collecting and Processing Streambed Sediment and Pore Water for Analysis of Mercury as  

E-Print Network [OSTI]

Procedures for Collecting and Processing Streambed Sediment and Pore Water for Analysis of Mercury Streambed Sediment and Pore Water for Analysis of Mercury as Part of the National Water-Quality Assessment for collecting and processing streambed sediment and pore water for analysis of mercury as part of the National

474

Rules to Ensure Good Scientific Practice at DESY Procedures in Case of Scientific Misconduct  

E-Print Network [OSTI]

resolution, and quality assurance to the scientific work units, and guarantee their implementation. SpecificRules to Ensure Good Scientific Practice at DESY and Procedures in Case of Scientific Misconduct Version: October 17, 2006 Preamble The directorate of DESY has adopted the rules decided upon by the HGF

475

Spent Nuclear Fuel Project document control and Records Management Program Description  

SciTech Connect (OSTI)

The Spent Nuclear Fuel (SNF) Project document control and records management program, as defined within this document, is based on a broad spectrum of regulatory requirements, Department of Energy (DOE) and Project Hanford and SNF Project-specific direction and guidance. The SNF Project Execution Plan, HNF-3552, requires the control of documents and management of records under the auspices of configuration control, conduct of operations, training, quality assurance, work control, records management, data management, engineering and design control, operational readiness review, and project management and turnover. Implementation of the controls, systems, and processes necessary to ensure compliance with applicable requirements is facilitated through plans, directives, and procedures within the Project Hanford Management System (PHMS) and the SNF Project internal technical and administrative procedures systems. The documents cited within this document are those which directly establish or define the SNF Project document control and records management program. There are many peripheral documents that establish requirements and provide direction pertinent to managing specific types of documents that, for the sake of brevity and clarity, are not cited within this document.

MARTIN, B.M.

2000-05-18T23:59:59.000Z

476

Quality assurance and data management  

SciTech Connect (OSTI)

This report contains graphs and tables relating to quality assurance and data management for environmental quality at Hanford Reservation.

Lockrem, L.L.

1998-01-12T23:59:59.000Z

477

Quality Manual-sample  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Q-001 Quality Manual 11_0329 Page 1 of 33 Q-001 Quality Manual 11_0329 Page 1 of 33 EOTA - Quality Manual Document Title: Quality Manual Document Number: Q-001 Rev. 11_0329 Document Owner: Elizabeth Sousa Backup Owner: Melissa Otero Approver(s): Melissa Otero Parent Document: N/A Notify of Changes: EOTA Employees Referenced Document(s): Various Q-001 Quality Manual 11_0329 Page 2 of 33 Revision History: Rev. Level Description of Change A Initial Release B Section V - added justification for exclusion "....because EOTA does not require the use of monitoring and measurement devices in the conduct of business." 07_1205 Added MGTP-004, Employee Satisfaction to Quality Manual 08_0818 Changed P-008 from Corrective Action and Preventive Action to read Corrective/Preventive Action & Improvement Opportunity

478

Downhole steam quality measurement  

DOE Patents [OSTI]

The present invention relates to an empirical electrical method for remote sensing of steam quality utilizing flow-through grids which allow measurement of the electrical properties of a flowing two-phase mixture. The measurement of steam quality in the oil field is important to the efficient application of steam assisted recovery of oil. Because of the increased energy content in higher quality steam it is important to maintain the highest possible steam quality at the injection sandface. The effectiveness of a steaming operation without a measure of steam quality downhole close to the point of injection would be difficult to determine. Therefore, a need exists for the remote sensing of steam quality.

Lee, D.O.; Montoya, P.C.; Muir, J.F.; Wayland, J.R. Jr.

1985-06-19T23:59:59.000Z

479

Chapter 10 Water Quality Standards (Kentucky) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

10 Water Quality Standards (Kentucky) 10 Water Quality Standards (Kentucky) Chapter 10 Water Quality Standards (Kentucky) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Kentucky Program Type Environmental Regulations Provider Department for Environmental Protection This administrative regulation establishes procedures to protect the

480

Analysis from robust control under environment constraint: application for traffic model  

Science Journals Connector (OSTI)

Traffic management solutions are increasingly called for to address problems of transport and mobility and nowadays, even to address the environmental impact. Traffic control uses strategies to reduce bottlenecks, travel time and costs. Although it is usually assumed that an improved traffic flow will result in lower vehicle emissions, little scientific research has been done concerning the effects of traffic control on emissions. Moreover, because changes in traffic flow do not necessarily influence travel times, noise and air quality in the same way, there is a clear need for a combined approach. The main idea was to apply control strategy on the road under the assumption of ensuring fluid traffic flow. In the following the gas emissions were evaluated as results of this regulation procedure. The proposed control approach is based on non-integer robust methodology. The chosen study case is a macroscopic traffic flow model.

Milka Uzunova; Mohamed Djemai

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality control procedures" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

FAQS Qualification Card - Weapon Quality Assurance | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Weapon Quality Assurance Weapon Quality Assurance FAQS Qualification Card - Weapon Quality Assurance A key element for the Department's Technical Qualification Programs is a set of common Functional Area Qualification Standards (FAQS) and associated Job Task Analyses (JTA). These standards are developed for various functional areas of responsibility in the Department, including oversight of safety management programs identified as hazard controls in Documented Safety Analyses (DSA). For each functional area, the FAQS identify the minimum technical competencies and supporting knowledge and skills for a typical qualified individual working in the area. FAQC-WeaponQualityAssurance.docx Description Weapon Quality Assurance Qualification Card More Documents & Publications DOE-STD-1025-2008

482

FAQS Qualification Card - Safety Software Quality Assurance | Department  

Broader source: Energy.gov (indexed) [DOE]

Safety Software Quality Assurance Safety Software Quality Assurance FAQS Qualification Card - Safety Software Quality Assurance A key element for the Department's Technical Qualification Programs is a set of common Functional Area Qualification Standards (FAQS) and associated Job Task Analyses (JTA). These standards are developed for various functional areas of responsibility in the Department, including oversight of safety management programs identified as hazard controls in Documented Safety Analyses (DSA). For each functional area, the FAQS identify the minimum technical competencies and supporting knowledge and skills for a typical qualified individual working in the area. FAQC-SafetySoftwareQualityAssurance.docx Description Safety Software Quality Assurance Qualification Card More Documents & Publications

483

Standard Operating Procedures Template for Highly Hazardous Chemicals Title of Procedure  

E-Print Network [OSTI]

1 Standard Operating Procedures Template for Highly Hazardous Chemicals Title of Procedure: Date or the procedure.) Examples include: 1) Chemical hazards such as carcinogenic, irritant, corrosive, acutely toxic 2 of exposure associated with the procedure such as inhalation, injection, skin/eye contact) Exposure Limit: (As

484

PROCEDURES FOR ACCESS TO AND CORRECTION OF INFORMATION Procedural Authority: University Secretary Effective Date: January, 2010  

E-Print Network [OSTI]

PROCEDURES FOR ACCESS TO AND CORRECTION OF INFORMATION Procedural Authority: University Secretary Effective Date: January, 2010 Procedural Officer: University Archivist Supersedes: New Last Editorial Change of these procedures is to set out how the university will manage: · freedom of information requests; · requests

Victoria, University of

485

Document Control Process  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

1 Document Control Process 11_0304 Page 1 of 7 1 Document Control Process 11_0304 Page 1 of 7 EOTA - Business Process Document Title: Document Control Process Document Number: P-001 Rev 11_0304 Document Owner: Elizabeth Sousa Backup Owner: Melissa Otero Approver(s): Melissa Otero Parent Document: Q-001, Quality Manual Notify of Changes: EOTA Employees Referenced Document(s): F-001 Document Control Template - Process, F-002 Document Control Template - Instruction, F-003 Document Control Template - Screenshot, F-004 Document Control Template - Form, F-005 Document Control Template - Form - Excel, MGTP-002 Skill Set Model, Q-003 EOTA Processes: Sequence and Interaction, P-003, Control of Records P-001 Document Control Process 11_0304 Page 2 of 7 Revision History: Rev. Description of Change

486

Sydney opera house glass walls: Colour measurement and control  

Science Journals Connector (OSTI)

One of the architectural requirements of the tinted laminated glass used in the construction of the Sydney Opera House glass walls was that it should be uniform in colour relative to an initially accepted colour standard. As the glass was manufactured in small batches over a two year period, stringent controls were needed to maintain the necessary colour quality of the laminate. The procedures adopted to check uniformity of colour are described and results are given of colorimetric analyses carried out on the colour standards and the production control specimens. The chromaticity data are interpreted in terms of subjective colour discrimination and are shown to be compatible with visual observations of the glass in situ.

J.A. Hooper; M.P. Wassall

1975-01-01T23:59:59.000Z

487

Quality Work Plan Update  

Energy Savers [EERE]

resources and quality assurance Improving long term sustainability by building the foundation of the national industry with WAP at the core 2 Responding to Network Concerns...

488

Safety & Quality Assurance  

Broader source: Energy.gov [DOE]

Together, our Facility Operations Division and Engineering, Safety and Quality Division work to ensure EM conducts its operations and cleanup safely through sound practices. These divisions ensure...

489

Air-Quality Regulations  

Science Journals Connector (OSTI)

n...Federal, state and/or local regulations constructed for the purpose of protecting air quality, e.g., low volatile organic compounds...

Jan W. Gooch

2011-01-01T23:59:59.000Z

490

Air-quality regulations  

Science Journals Connector (OSTI)

n....Federal, state and/or local regulations constructed for the purpose of protecting air quality, e.g., low volatile organic compounds...

2007-01-01T23:59:59.000Z

491

Section 22: Quality Assurance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Quality Assurance (40 CFR 194.22) United States Department of Energy Waste Isolation Pilot Plant Carlsbad Field Office Carlsbad, New Mexico Compliance Recertification...

492

SCIENTIFIC NOTE Variations in daily quality assurance dosimetry from device  

E-Print Network [OSTI]

SCIENTIFIC NOTE Variations in daily quality assurance dosimetry from device levelling, feet procedures are an essential part of radiotherapy medical physics. Devices such as the Sun Nuclear, DQA3 are effective tools for analysis of daily dosimetry including flatness, symmetry, energy, field size and central

Yu, K.N.

493

HUMAN RELIABILITY ANALYSIS FOR COMPUTERIZED PROCEDURES, PART TWO: APPLICABILITY OF CURRENT METHODS  

SciTech Connect (OSTI)

Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no U.S. nuclear power plant has implemented CPs in its main control room. Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

Ronald L. Boring; David I. Gertman

2012-10-01T23:59:59.000Z

494

CONSIDERATIONS FOR THE TREATMENT OF COMPUTERIZED PROCEDURES IN HUMAN RELIABILITY ANALYSIS  

SciTech Connect (OSTI)

Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no US nuclear power plant has implemented CPs in its main control room. Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

Ronald L. Boring; David I. Gertman

2012-07-01T23:59:59.000Z

495

EM Quality Assurance Program (EM-QA-001 Revision 0)  

Broader source: Energy.gov (indexed) [DOE]

I I ~ r h b 1tv2om m ~ e e of Environments1M a ~ f p ~ ~ ! n n t (EM) Snbjeet: E M Quality Asamnee Program (QBP) Policies, Procedures, APPROVED: and Plans Principal Deputy Secretary for Environmental Management 1.0 PURPOSE AND OBJECTIVE The purpose of this document is to describe the U.S. Department of Energy (DOE), Office of Environmental Management (EM) Quality Assurance Program (QAP). The QAP is the EM management system to ensure we "do work correctly." The QAP meets the requirements of DOE 0 414. IC, Quality Assurance, and 10 CFR 830 Subpart A "Quality Assurance Requirements." It is intended that the requirements of DOE 0 414.1C and 10 CFR 830 Subpart A are met by implementing this QAP. The QAP provides EM expectations for implementing quality assurance (QA) across the EM complex. The QAP

496

Signatures for Mass Spectrometry Data Quality  

SciTech Connect (OSTI)

Ensuring data quality and proper instrument functionality is a prerequisite for scientific investigation. Manual validation for quality assurance is time consuming, expensive and subjective. Metrics for describing various features of LC-MS data have been developed to assist operators in discriminating poor (out of control) and good (in control) datasets. However, the wide variety of instrument specifications and LC-MS configurations precludes applying a simple range of acceptable values or cutoffs for such metrics. We explored a variety of statistical modeling approaches to predict the quality of LC-MS data. Using 1164 manually classified quality control (QC) LC-MS datasets, we fit logistic regression classification models to the QC data to predict whether a dataset is in or out of control. Model parameters were optimized by minimizing a loss function that accounts for the tradeoff between false positive and false negative errors. The optimal logistic regression classifier models detected bad data sets with high sensitivity (i.e. low false negative rate) while maintaining high specificity (i.e. controlling the false positive rate). As an example, predictions for Velos-Orbitrap instrumentation data had a sensitivity of 93.7% in detecting out of control datasets with a false positive rate of 8.3%. In comparison, we investigated the performance of several single metrics in predicting dataset quality. While maintaining a sensitivity of 93.7%, the corresponding false positive rates for these single-metric models unacceptably ranged from 32% to 97.7%. Finally, we evaluated the performance of the

Amidan, Brett G.; Orton, Daniel J.; Lamarche, Brian L.; Monroe, Matthew E.; Moore, Ronald J.; Venzin, Alexander M.; Smith, Richard D.; Sego, Landon H.; Tardiff, Mark F.; Payne, Samuel H.

2014-03-10T23:59:59.000Z

497

Council on Environmental Quality | Open Energy Information  

Open Energy Info (EERE)

Environmental Quality Environmental Quality Jump to: navigation, search Logo: Council on Environmental Quality Name Council on Environmental Quality Address 722 Jackson Place Northwest Place Washington, DC Zip 20506 Year founded 1969 Phone number (202) 395-5750 Website http://www.whitehouse.gov/admi Coordinates 38.89943°, -77.0384009° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.89943,"lon":-77.0384009,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

498

Environmental Quality Improvement Act of 1970  

Broader source: Energy.gov (indexed) [DOE]

QUALITY IMPROVEMENT ACT OF 1970* QUALITY IMPROVEMENT ACT OF 1970* SHORT TITLE This title may be cited as the "Environmental Quality Improvement Act of 1970" Sec. 4371. Congressional findings, declarations, and purposes (a) The Congress finds - (1) that man has caused changes in the environment; (2) that many of these changes may affect the relationship between man and his environment; and (3) that population increases and urban concentration contribute directly to pollution and the degradation of our environment. (b)(1)The Congress declares that there is a national policy for the environment which provides for the enhancement of environmental quality. This policy is evidenced by statutes heretofore enacted relating to the prevention, abatement, and control of environmental pollution, water and land resources, transportation, and economic and

499

NETL: IEP - Air Quality Research: Regulatory Drivers  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Regulatory Drivers Regulatory Drivers DOE/NETL’s Air Quality Research Program is in direct response to the need to ensure that fossil-fuel-fired power systems continue to meet current and future environmental requirements. Specific environmental regulatory requirements driving this research are briefly summarized below: I. Clean Air Act (Including 1990 Amendments) Title I - Air Pollution Prevention and Control Part A - Air Quality and Emission Limitations Sect. 109 - National Ambient Air Quality Standards In July 1997 EPA promulgated new standards for particulate matter finer than 2.5 micrometers (PM2.5) and revised the ambient ozone standards. Sect. 111 - Standards of Performance for New Stationary Sources Part C - Prevention of Significant Deterioration of Air Quality

500

POLICY AND PROCEDURES REGARDING ALLEGATIONS OF RESEARCH MISCONDUCT  

E-Print Network [OSTI]

POLICY AND PROCEDURES REGARDING ALLEGATIONS OF RESEARCH MISCONDUCT Policy Statement Research.................................................................................................1 Policy/Procedures AND PROCEDURES REGARDING ALLEGATIONS OF RESEARCH MISCONDUCT 2 Contacts

Vertes, Akos