Powered by Deep Web Technologies
Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Quality Assurance Program Plan  

Broader source: Energy.gov [DOE]

The achievement of quality in LM activities and products requires implementation of a formal Quality Assurance (QA) Program. This program establishes principles, requirements, practices, and...

2

Quality Assurance Program Guide  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Guide provides information on principles, requirements, and practices used to establish and implement an effective Quality Assurance Program. Cancels DOE G 414.1-2A, DOE G 414.1-3 and DOE G 414.4-5. Admin Chg 1, dated 9-27-11. Admin Chg 2, dated 5-8-13.

2011-08-16T23:59:59.000Z

3

Quality Assurance Program Guide  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The directive provides guidance for DOE elements and contractors in developing and implementing an effective Quality Assurance Program. Cancels DOE G 414.1-2A, DOE G 414.1-3 and DOE G 414.1-5. Superseded by Admin Chg 1, 9-27-11.

2011-08-16T23:59:59.000Z

4

Quality Assurance Program Guide  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Guide provides information on principles, requirements, and practices used to establish and implement an effective Quality Assurance Program. Cancels DOE G 414.1-2A, DOE G 414.1-3 and DOE G 414.1-5. Admin Chg 1, dated 9-27-11. Admin Chg 2, dated 5-8-13.

2011-08-16T23:59:59.000Z

5

Quality Assurance for Residential Retrofit Programs | Department...  

Broader source: Energy.gov (indexed) [DOE]

Quality Assurance for Residential Retrofit Programs Quality Assurance for Residential Retrofit Programs Blue version of the EERE PowerPoint template, for use with PowerPoint 2007....

6

Quality Assurance Program Plan for FFTF effluent controls. Revision 1  

SciTech Connect (OSTI)

This Quality Assurance Program Plan is specific to environmental related activities within the FFTF Property Protected Area. The activities include effluent monitoring and Low Level Waste Certification.

Seamans, J.A.

1995-06-08T23:59:59.000Z

7

Transuranic Waste Characterization Quality Assurance Program Plan  

SciTech Connect (OSTI)

This quality assurance plan identifies the data necessary, and techniques designed to attain the required quality, to meet the specific data quality objectives associated with the DOE Waste Isolation Pilot Plant (WIPP). This report specifies sampling, waste testing, and analytical methods for transuranic wastes.

NONE

1995-04-30T23:59:59.000Z

8

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To establish an effective management system [i.e., quality assurance programs (QAPs)] using the performance requirements of this Order, coupled with technical standards where appropriate. Cancels DOE O 414.1.

1999-09-29T23:59:59.000Z

9

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To provide Department of Energy (DOE) policy, set forth principles, and assign responsibilities for establishing, implementing, and maintaining programs of plans and actions to assure quality achievement in DOE programs. Canceled by DOE O 5700.6A, dated 7-21-1981.

1981-01-16T23:59:59.000Z

10

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To provide Department of Energy (DOE) policy, set forth principles, and assign responsibilities for establishing, implementing, and maintaining programs of plans and actions to assure quality achievement in DOE programs. Cancels DOE O 5700.6, dated 1-16-1981. Canceled by DOE O 5700.6B, dated 9-23-1986.

1981-07-21T23:59:59.000Z

11

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To establish an effective management system [i.e., quality assurance programs(QAPs)] using the performance requirements of this Order, coupled with technical standards where appropriate. Change 1, dated 7/12/01, facilitates the Department's organizational transition necessitated by establishment of the NNSA. (Attachment 2 of this Order is canceled by DOE O 470.2B.) Cancels: DOE O 414.1

2001-07-12T23:59:59.000Z

12

External Quality Assurance Services (EQAS) Ethanol/Ammonia Program  

E-Print Network [OSTI]

External Quality Assurance Services (EQAS) Ethanol/Ammonia Program BC35 12 x 3 mL 2 Analytes QC35 12 x 3 mL Specimen Only ENGLISH INTENDED USE Bio-Rad EQAS Ethanol/Ammonia Program is designed

Rodriguez, Carlos

13

ERD UMTRA Project quality assurance program plan, Revision 7  

SciTech Connect (OSTI)

This document is the revised Quality Assurance Program Plan (QAPP) dated September, 1995 for the Environmental Restoration Division (ERD) Uranium Mill Tailings Remedial Action Project (UMTRA). Quality Assurance requirements for the ERD UMTRA Project are based on the criteria outlined in DOE Order 5700.6C or applicable sections of 10 CFR 830.120. QA requirements contained in this QAPP shall apply to all personnel, processes, and activities, including planning, scheduling, and cost control, performed by the ERD UMTRA Project and its contractors.

NONE

1995-09-01T23:59:59.000Z

14

Plutonium stabilization and handling quality assurance program plan  

SciTech Connect (OSTI)

This Quality Assurance Program Plan (QAPP) identifies project quality assurance requirements for all contractors involved in the planning and execution of Hanford Site activities for design, procurement, construction, testing and inspection for Project W-460, Plutonium Stabilization and Handling. The project encompasses procurement and installation of a Stabilization and Packaging System (SPS) to oxidize and package for long term storage remaining plutonium-bearing special nuclear materials currently in inventory at the Plutonium Finishing Plant (PFP), and modification of vault equipment to allow storage of resulting packages of stabilized SNM.

Weiss, E.V.

1998-04-22T23:59:59.000Z

15

Quality Assurance Specialist  

Broader source: Energy.gov [DOE]

Alternate Title(s):Quality Control Technician; Quality Assurance Inspector; Quality Assurance Representative

16

UMTRA Project Office quality assurance program plan. Revision 6  

SciTech Connect (OSTI)

The Uranium Mill Tailings Remedial Action (UMTRA) Project was established to accomplish remedial actions at inactive uranium mill tailings sites. The UMTRA Project`s mission is to stabilize and control the residual radioactive materials at designated sites in a safe and environmentally sound manner so as to minimize or eliminate radiation health hazards to the public. Because these efforts may involve possible risks to public health and safety, a quality assurance (QA) program that conforms to the applicable criteria has been established to control the quality of the work. This document, the Quality Assurance Program Plan (QAPP), brings into one document the essential criteria to be applied on a selective basis, depending upon the nature of the activity being conducted, and describes how those criteria shall be applied to the UMTRA Project. QA requirements contained in this QAPP shall apply to all personnel, processes, and activities, including planning, scheduling, and cost control, performed by the UMTRA Project Office and its contractors.

Not Available

1994-09-01T23:59:59.000Z

17

National Ignition Facility Quality Assurance Program Plan. Revision 1  

SciTech Connect (OSTI)

The National Ignition Facility (NIF) is a key constituent of the Department of Energy`s Stockpile Stewardship Program. The NIF will use inertial confinement fusion (ICF) to produce ignition and energy gain in ICF targets, and will perform weapons physics and high-energy- density experiments in support of national security and civilian objectives. The NIF Project is a national facility involving the collaboration of several DOE laboratories and subcontractors, including Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), and the University of Rochester Laboratory for Laser Energetics (UR/LLE). The primary mission of the NIF Project is the construction and start-up operation of laser-based facilities that will demonstrate fusion ignition in the laboratory to provide nuclear-weapons-related physics data, and secondarily, to propagate fusion burn aimed at developing a potential source of civilian energy. To support the accomplishment of this very important mission, the LLNL Laser Directorate created the NIF Project Office to organize and bring about the Project. The NIF Project Office has established this Quality Assurance Program to ensure its success. This issue of the Quality Assurance Program Plan (QAPP) adds the requirements for the conduct of Title 11 design, construction, procurement, and Title III engineering. This QAPP defines and describes the program-the management system-for specifying, achieving, and assuring the quality of all NIF Project work consistent with the policies of the Laboratory and the Laser Directorate.

Wolfe, C.R.; Yatabe, J.

1996-09-01T23:59:59.000Z

18

Quality assurance program plan for cesium legacy project  

SciTech Connect (OSTI)

This Quality Assurance Program Plan (QAPP) provides information on how the Quality Assurance Program is implemented for the Cesium Legacy Project. It applies to those items and tasks which affect the completion of activities identified in the work breakdown structure of the Project Management Plan (PMP). These activities include all aspects of cask transportation, project related operations within the 324 Building, and waste management as it relates to the specific activities of this project. General facility activities (i.e. 324 Building Operations, Central Waste Complex Operations, etc.) are covered in other appropriate QAPPs. The 324 Building is currently transitioning from being a Pacific Northwest National Laboratory (PNNL) managed facility to a B and W Hanford Company (BWHC) managed facility. During this transition process existing PNNL procedures and documents will be utilized until replaced by BWHC procedures and documents.

Tanke, J.M.

1997-05-22T23:59:59.000Z

19

Management and overview Quality Assurance Program Plan. Revision 2  

SciTech Connect (OSTI)

The Uranium Mill Tailings Remedial Action (UMTRA) Project Office (DOE/ UMTRA-PO) is the US Department of Energy (DOE) Albuquerque Operations Office (AL) organization charged with the responsibility of managing and coordinating the activities of the various participating organizations and support contractors working on the UMTRA Project. This Quality Assurance Program Plan (QAPP) describes how the DOE/UMTRA-PO, as assisted by the Technical Assistance Contractor (TAC), performs the quality assurance (QA) aspects of managing and coordinating UMTRA Project activities. This QAPP was developed to comply with DOE Order 5700.6A, August, 1981, and AL Order 5700.6B, April, 1984, which contain the criteria applicable to Project QA activities.

Not Available

1986-08-01T23:59:59.000Z

20

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Order ensures that the quality of DOE/NNSA products and services meets or exceeds the customer's expectations. This Order cancels DOE O 414.1A, Quality Assurance, dated 9-29-99, and Attachment 1, paragraph 8, and Attachment 2, paragraph 22, of DOE O 440.1A, Worker Protection Management for DOE Federal and Contractor Employees, dated 3-27-98. Cancels: DOE O 414.1A and DOE O 440.1A, parts as noted.

2004-04-29T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

UMTRA Project Office Quality Assurance Program Plan. Revision 5  

SciTech Connect (OSTI)

The Uranium Mill Tailings Remedial Action (UMTRA) Project was established to accomplish remedial actions at inactive uranium mill tailings sites in accordance with Public Law 95-604, the Uranium Mill Tailings Radiation Control Act of 1978 (UMTRCA). The UMTRA Project`s mission is to stabilize and control the residual radioactive materials at designated sites in a safe and environmentally sound manner so as to minimize or eliminate radiation health hazards to the public. The US Department of Energy (DOE) UMTRA Project Office directs the overall Project. Because these efforts may involve possible risks to public health and safety, a quality assurance (QA) program that conforms to the applicable criteria (set forth in the reference documents) has been established to control the quality of the work. This document, the Quality Assurance Program Plan (QAPP), brings into one document the essential criteria to be applied on a selective basis, depending upon the nature of the activity being conducted, and describes how those criteria shall be applied to the UMTRA Project. The UMTRA Project Office shall require each Project contractor to prepare and submit for approval a more detailed QAPP that is based on the applicable criteria of this QAPP and the referenced documents. All QAPPs on the UMTRA Project shall fit within the framework of this plan or an industry standard format that has been approved by the DOE Project Office.

Not Available

1993-11-01T23:59:59.000Z

22

Quality Assurance Program Plan (QAPP) Waste Management Project  

SciTech Connect (OSTI)

This document is the Quality Assurance Program Plan (QAPP) for Waste Management Federal Services of Hanford, Inc. (WMH), that implements the requirements of the Project Hanford Management Contract (PHMC), HNF-MP-599, Project Hanford Quality Assurance Program Description (QAPD) document, and the Hanford Federal Facility Agreement with Consent Order (Tri-Party Agreement), Sections 6.5 and 7.8. WHM is responsible for the treatment, storage, and disposal of liquid and solid wastes generated at the Hanford Site as well as those wastes received from other US Department of Energy (DOE) and non-DOE sites. WMH operations include the Low-Level Burial Grounds, Central Waste Complex (a mixed-waste storage complex), a nonradioactive dangerous waste storage facility, the Transuranic Storage Facility, T Plant, Waste Receiving and Processing Facility, 200 Area Liquid Effluent Facility, 200 Area Treated Effluent Disposal Facility, the Liquid Effluent Retention Facility, the 242-A Evaporator, 300 Area Treatment Effluent Disposal Facility, the 340 Facility (a radioactive liquid waste handling facility), 222-S Laboratory, the Waste Sampling and Characterization Facility, and the Hanford TRU Waste Program.

VOLKMAN, D.D.

1999-10-27T23:59:59.000Z

23

Quality Assurance of ARM Program Climate Research Facility Data  

SciTech Connect (OSTI)

This report documents key aspects of the Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) data quality assurance program as it existed in 2008. The performance of ACRF instruments, sites, and data systems is measured in terms of the availability, usability, and accessibility of the data to a user. First, the data must be available to users; that is, the data must be collected by instrument systems, processed, and delivered to a central repository in a timely manner. Second, the data must be usable; that is, the data must be inspected and deemed of sufficient quality for scientific research purposes, and data users must be able to readily tell where there are known problems in the data. Finally, the data must be accessible; that is, data users must be able to easily find, obtain, and work with the data from the central repository. The processes described in this report include instrument deployment and calibration; instrument and facility maintenance; data collection and processing infrastructure; data stream inspection and assessment; the roles of value-added data processing and field campaigns in specifying data quality and haracterizing the basic measurement; data archival, display, and distribution; data stream reprocessing; and engineering and operations management processes and procedures. Future directions in ACRF data quality assurance also are presented.

RA Peppler; KE Kehoe; KL Sonntag; CP Bahrmann; SJ Richardson; SW Christensen; RA McCord; DJ Doty; R Wagener; RC Eagan; JC Lijegren; BW Orr; DL Sisterson; TD Halter; NN Keck; CN Long; MC Macduff; JH Mather; RC Perez; JW Voyles; MD Ivey; ST Moore; DL Nitschke; BD Perkins; DD Turner

2008-03-01T23:59:59.000Z

24

Quality Assurance (QA) Program Plan Conceptual Design Phase of Project W-521 Waste Feed Delivery Systems [SUPERSEDED BY RPP-6649 Rev. 0  

SciTech Connect (OSTI)

The Quality Assurance Program Plan (QAPP) describes the quality assurance implementation strategy for Project W-521 during conceptual design.

WHITE, K.A.

2000-08-02T23:59:59.000Z

25

Waste Encapsulation and Storage Facility (WESF) Quality Assurance Program Plan (QAPP)  

SciTech Connect (OSTI)

This Quality Assurance Plan describes how the Waste Encapsulation and Storage Facility (WESF) implements the quality assurance (QA) requirements of the Quality Assurance Program Description (QAPD) (HNF-Mp-599) for Project Hanford activities and products. This QAPP also describes the organizational structure necessary to successfully implement the program. The QAPP provides a road map of applicable Project Hanford Management System Procedures, and facility specific procedures, that may be utilized by WESF to implement the requirements of the QAPD.

ROBINSON, P.A.

2000-04-17T23:59:59.000Z

26

Quality Assurance Program Plan for AGR Fuel Development and Qualification Program  

SciTech Connect (OSTI)

Quality Assurance Plan (QPP) is to document the Idaho National Engineering and Environmental Laboratory (INEEL) Management and Operating (M&O) Contractor’s quality assurance program for AGR Fuel Development and Qualification activities, which is under the control of the INEEL. The QPP is an integral part of the Gen IV Program Execution Plan (PEP) and establishes the set of management controls for those systems, structures and components (SSCs) and related quality affecting activities, necessary to provide adequate confidence that items will perform satisfactorily in service.

W. Ken Sowder

2004-02-01T23:59:59.000Z

27

Quality Assurance Exchange, December 2005  

Broader source: Energy.gov (indexed) [DOE]

the EM-HQ Quality Assur- ance Program Plan (QAPP), the benefits of having a DOE Order on QA, and the EM Quality Assurance goals. Describe your role as QA Administrator for...

28

Plutonium Immobilization Project, Project Office Quality Assurance Program Description Revision 1  

SciTech Connect (OSTI)

''The quality assurance activity involves the establishment and implementation of the Quality Assurance Program and the development of a Quality Assurance Plan and Procedures. Quality Assurance provides the plans, procedures and controls that are required for repository acceptance and the immobilization plant licensing and design activities.'' The Plutonium Immobilization Project (PIP) has a policy that all development, testing and operational activities be planned and performed in accordance with its customer's needs and expectations, and with a commitment to excellence and continuous improvement. The Immobilization Development and Testing (D&T) Quality Assurance Program establishes implementation requirements which, when completed, will ensure that the program development and test activities conform to the appropriate QA requirements. In order for the program to be effective, a designated quality lead must be in place at the Project Office and each participating site.

Kan, T.

1998-04-30T23:59:59.000Z

29

Quality Assurance Program Application for the Component Test Capability  

SciTech Connect (OSTI)

This paper documents the application of quality requirements to Component Test Capability (CTC) Project activities for each CTC alternative. Four alternatives are considered for quality program application: do nothing, vendor testing, existing testing facility modification, and Component Test Facility. It also describes the advantages and disadvantages of using the existing Next Generation Nuclear Plant Quality Program Plan with CTC modifications versus a stand-alone CTC Quality Program Plan.

Stephanin L. Austad

2009-06-01T23:59:59.000Z

30

Quality Assurance Program Plan for TRUPACT-II Gas Generation Test Program  

SciTech Connect (OSTI)

The Gas Generation Test Program (GGTP), referred to as the Program, is designed to establish the concentration of flammable gases and/or gas generation rates in a test category waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II). The phrase "gas generationtesting" shall refer to any activity that establishes the flammable gas concentration or the flammable gas generation rate. This includes, but is not limited to, measurements performed directly on waste containers or during tests performed on waste containers. This Quality Assurance Program Plan (QAPP) documents the quality assurance (QA) and quality control (QC) requirements that apply to the Program. The TRUPACT-II requirements and technical bases for allowable flammable gas concentration and gas generation rates are described in the TRUPACT-II Authorized Methods for Payload Control (TRAMPAC).

Carlsbad Field Office

2002-03-01T23:59:59.000Z

31

Westinghouse Hanford Company quality assurance program and implementation plan  

SciTech Connect (OSTI)

This is the first revision of the Quality AssurancePlan/Implementation Plan (QAP/IP) for nuclear facilities managedand operated by the Westinghouse Hanford Company (WHC).Development of the initial IP required review of the WHC qualityassurance program to the requirements of the 10 CFR 830.120, andcompletion of initial baseline assessments against the QAP toverify implementation of the program. Each WHC-managed nuclearfacility provided a stand-alone section to the QAP/IP, describingits mission and life-cycle status. WHC support organizationsalso performed assessments for their lead areas, and providedinputs to a separate stand-alone section with the initialbaseline assessment results. In this first revision, the initialbaseline matrixes for those facilities found to be in compliancewith the QAP have been removed. Tank Waste Remediation System(TWRS) and K Basins have modified their baseline matrixes to showcompletion of action items to date. With the followingexceptions, the WHC-managed nuclear facilities and their supportorganizations were found to have implemented QA programs thatsatisfy the requirements of 10 CFR 830.120. TWRS identifiedImplementation Plan Action Items having to do with: generationand revision of as-built drawings; updating TWRS organizationaland program documents; tracking the condition/age ofmaterials/equipment; and reconstitution of design bases forexisting, active facilities. No incremental funding needs wereidentified for FY95. For FY97, TWRS identified incrementalfunding in the amount of $65,000 for as-built drawings, and$100,000 for tracking the age/condition of materials/equipment.The K Basin Fuel Storage Facility identified Implementation PlanAction Items having to do with: training; updating procedures;establishing configuration management; reconstituting designbases; and providing darwings; and developing integrated,resource-loaded schedules. Incremental funding needs in theamount of $1.7 million were identified, over a time periodthrough March 1996, to implement the actions. The costs were allassociated with the actions on training ($300K) and configurationmanagement, design bases, and drawings ($1.4M). Schedulardetails and compensatory measures for the action items areprovided in Appendices A and D to this document.

Moss, S.S., Westinghouse Hanford

1996-07-01T23:59:59.000Z

32

Quality assurance program plan for the Site Physical and Electrical Calibration Services Lab. Revision 1  

SciTech Connect (OSTI)

This Quality Assurance Program Plan (QAPP) is organized to address WHC`s implementation of quality assurance requirements as they are presented as interpretive guidance endorsed by the Department of Energy (DOE) Field Office, Richland DOE Order 5700.6C Quality Assurance. The quality assurance requirements presented in this plan will assure Measuring and Test Equipment (M and TE) are in conformance with prescribed technical requirements and that data provided by testing, inspection, or maintenance are valid. This QAPP covers all activities and work elements that are variously called QA, quality control, and quality engineering regardless of the organization performing the work. This QAPP identifies the QA requirements for planning, control, and documentation of operations, modifications, and maintenance of the WHC Site Physical and Electrical Calibration Services Laboratory. The primary function of the WHC Site Physical and Electrical Calibration Services Laboratory is providing calibration, standardization, or repair service of M and TE.

Carpenter, C.A.

1995-03-02T23:59:59.000Z

33

Track 9: Quality Assurance  

Broader source: Energy.gov [DOE]

ISM Workshop Presentations Knoxville Convention Center, Knoxville, TN August 2009 Track 9: Quality Assurance

34

Quality assurance program plan for FRG sealed isotopic heat sources project (C-229)  

SciTech Connect (OSTI)

This QAPP implements the Quality Assurance Program Plan for the FRG Sealed Isotopic Heat Sources Project (C-229). The heat source will be relocated from the 324 Building and placed in interim storage at the Central Waste Complex (CWC).

Tanke, J.M.

1997-05-16T23:59:59.000Z

35

Standard guide for establishing a quality assurance program for uranium conversion facilities  

E-Print Network [OSTI]

1.1 This guide provides guidance and recommended practices for establishing a comprehensive quality assurance program for uranium conversion facilities. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate health and safety practices and determine the applicability of regulatory limitations prior to use. 1.3 The basic elements of a quality assurance program appear in the following order: FUNCTION SECTION Organization 5 Quality Assurance Program 6 Design Control 7 Instructions, Procedures & Drawings 8 Document Control 9 Procurement 10 Identification and Traceability 11 Processes 12 Inspection 13 Control of Measuring and Test Equipment 14 Handling, Storage and Shipping 15 Inspection, Test and Operating Status 16 Control of Nonconforming Items 17 Corrective Actions 18 Quality Assurance Records 19 Audits 20 TABLE 1 NQA-1 Basic Requirements Relat...

American Society for Testing and Materials. Philadelphia

2004-01-01T23:59:59.000Z

36

Office of Quality Assurance  

Broader source: Energy.gov [DOE]

The Office of Quality Assurance establishes and maintains the quality assurance (QA) policies, requirements and guidance for the Department and serves as DOE's corporate resource to ensure that products and services meet or exceed the Department’s quality objectives.

37

QUALITY ASSURANCE EXCHANGE July 2005 Volume 1 Issue 1  

Broader source: Energy.gov [DOE]

QUALITY ASSURANCE EXCHANGE July 2005 Volume 1 Issue 1 US Department of Energy, Office of Quality Assurance Programs (EH-31)

38

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Order ensures that the quality of DOE/NNSA products and services meets or exceeds the customers' expectations. Cancels DOE O 414.1B and DOE N 411.1. Canceled by DOE O 414.1D.

2005-06-17T23:59:59.000Z

39

Sandia National Laboratories, California Quality Assurance Project Plan for Environmental Monitoring Program.  

SciTech Connect (OSTI)

This Quality Assurance Project Plan (QAPP) applies to the Environmental Monitoring Program at the Sandia National Laboratories/California. This QAPP follows DOE Quality Assurance Management System Guide for Use with 10 CFR 830 Subpart A, Quality Assurance Requirements, and DOE O 414.1C, Quality Assurance (DOE G 414.1-2A June 17, 2005). The Environmental Monitoring Program is located within the Environmental Operations Department. The Environmental Operations Department is responsible for ensuring that SNL/CA operations have minimal impact on the environment. The Department provides guidance to line organizations to help them comply with applicable environmental regulations and DOE orders. To fulfill its mission, the department has groups responsible for waste management; pollution prevention, air quality; environmental planning; hazardous materials management; and environmental monitoring. The Environmental Monitoring Program is responsible for ensuring that SNL/CA complies with all Federal, State, and local regulations and with DOE orders regarding the quality of wastewater and stormwater discharges. The Program monitors these discharges both visually and through effluent sampling. The Program ensures that activities at the SNL/CA site do not negatively impact the quality of surface waters in the vicinity, or those of the San Francisco Bay. The Program verifies that wastewater and stormwater discharges are in compliance with established standards and requirements. The Program is also responsible for compliance with groundwater monitoring, and underground and above ground storage tanks regulatory compliance. The Program prepares numerous reports, plans, permit applications, and other documents that demonstrate compliance.

Holland, Robert C.

2005-09-01T23:59:59.000Z

40

Quality Assurance Program Undergoes Sound Changes to Ensure Safe, Correct Work  

Broader source: Energy.gov [DOE]

WASHINGTON, D.C. – Completing the world’s largest nuclear cleanup safely and correctly is EM’s priority. In support of that central mission, EM recently made changes that strengthen its corporate quality assurance program, marking the first revisions to the quality program since EM established it in 2008. The program provides the foundation for achieving quality through a consistent approach to all mission-related work across the EM complex.

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Quality Assurance Program Plan for the Waste Sampling and Characterization Facility  

SciTech Connect (OSTI)

The objective of this Quality Assurance Plan is to provide quality assurance (QA) guidance, implementation of regulatory QA requirements, and quality control (QC) specifications for analytical service. This document follows the Department of Energy (DOE)-issued Hanford Analytical Services Quality Assurance Plan (HASQAP) and additional federal [10 US Code of Federal Regulations (CFR) 830.120] QA requirements that HASQAP does not cover. This document describes how the laboratory implements QA requirements to meet the federal or state requirements, provides what are the default QC specifications, and/or identifies the procedural information that governs how the laboratory operates. In addition, this document meets the objectives of the Quality Assurance Program provided in the WHC-CM-4-2, Section 2.1. This document also covers QA elements that are required in the Guidelines and Specifications for Preparing Quality Assurance Program Plans (QAPPs), (QAMS-004), and Interim Guidelines and Specifications for Preparing Quality Assurance Product Plans (QAMS-005) from the Environmental Protection Agency (EPA). A QA Index is provided in the Appendix A.

Grabbe, R.R.

1995-03-02T23:59:59.000Z

42

Waste Management Quality Assurance Plan  

E-Print Network [OSTI]

Revision 6 Waste Management Quality Assurance Plan Waste6 WM QA Plan Waste Management Quality Assurance Plan LBNL/4 Management Quality Assurance

Waste Management Group

2006-01-01T23:59:59.000Z

43

Project Hanford management contract quality assurance program implementation plan for nuclear facilities  

SciTech Connect (OSTI)

During transition from the Westinghouse Hanford Company (WHC) Management and Operations (M and O) contract to the Fluor Daniel Hanford (FDH) Management and Integration (M and I) contract, existing WHC policies, procedures, and manuals were reviewed to determine which to adopt on an interim basis. Both WHC-SP-1131,Hanford Quality Assurance Program and Implementation Plan, and WHC-CM-4-2, Quality Assurance Manual, were adopted; however, it was recognized that revisions were required to address the functions and responsibilities of the Project Hanford Management Contract (PHMC). This Quality Assurance Program Implementation Plan for Nuclear Facilities (HNF-SP-1228) supersedes the implementation portion of WHC-SP-1 13 1, Rev. 1. The revised Quality Assurance (QA) Program is documented in the Project Hanford Quality Assurance Program Description (QAPD), HNF-MP-599. That document replaces the QA Program in WHC-SP-1131, Rev. 1. The scope of this document is limited to documenting the nuclear facilities managed by FDH and its Major Subcontractors (MSCS) and the status of the implementation of 10 CFR 830.120, Quality Assurance Requirements, at those facilities. Since the QA Program for the nuclear facilities is now documented in the QAPD, future updates of the information provided in this plan will be by letter. The layout of this plan is similar to that of WHC-SP-1 13 1, Rev. 1. Sections 2.0 and 3.0 provide an overview of the Project Hanford QA Program. A list of Project Hanford nuclear facilities is provided in Section 4.0. Section 5.0 provides the status of facility compliance to 10 CFR 830.120. Sections 6.0, 7.0, and 8.0 provide requested exemptions, status of open items, and references, respectively. The four appendices correspond to the four projects that comprise Project Hanford.

Bibb, E.K.

1997-10-15T23:59:59.000Z

44

Performance assurance program plan  

SciTech Connect (OSTI)

B and W Protec, Inc. (BWP) is responsible for implementing the Performance Assurance Program for the Project Hanford Management Contract (PHMC) in accordance with DOE Order 470.1, Safeguards and Security Program (DOE 1995a). The Performance Assurance Program applies to safeguards and security (SAS) systems and their essential components (equipment, hardware, administrative procedures, Protective Force personnel, and other personnel) in direct support of Category I and H special nuclear material (SNM) protection. Performance assurance includes several Hanford Site activities that conduct performance, acceptance, operability, effectiveness, and validation tests. These activities encompass areas of training, exercises, quality assurance, conduct of operations, total quality management, self assessment, classified matter protection and control, emergency preparedness, and corrective actions tracking and trending. The objective of the Performance Assurance Program is to capture the critical data of the tests, training, etc., in a cost-effective, manageable program that reflects the overall effectiveness of the program while minimizing operational impacts. To aid in achieving this objective, BWP will coordinate the Performance Assurance Program for Fluor Daniel Hanford, Inc. (FDH) and serve as the central point for data collection.

Rogers, B.H.

1997-11-06T23:59:59.000Z

45

Standard guide for establishing a quality assurance program for analytical chemistry laboratories within the nuclear industry  

E-Print Network [OSTI]

1.1 This guide covers the establishment of a quality assurance (QA) program for analytical chemistry laboratories within the nuclear industry. Reference to key elements of ANSI/ISO/ASQC Q9001, Quality Systems, provides guidance to the functional aspects of analytical laboratory operation. When implemented as recommended, the practices presented in this guide will provide a comprehensive QA program for the laboratory. The practices are grouped by functions, which constitute the basic elements of a laboratory QA program. 1.2 The essential, basic elements of a laboratory QA program appear in the following order: Section Organization 5 Quality Assurance Program 6 Training and Qualification 7 Procedures 8 Laboratory Records 9 Control of Records 10 Control of Procurement 11 Control of Measuring Equipment and Materials 12 Control of Measurements 13 Deficiencies and Corrective Actions 14

American Society for Testing and Materials. Philadelphia

2006-01-01T23:59:59.000Z

46

Quality Assurance 8-1 8. Quality Assurance  

E-Print Network [OSTI]

The overall goal of a well-designed and well-implemented sampling and analysis program is to measure of a quality assurance/quality control (QA/QC) program for environmental monitoring activities at the ORR sampling QA program and for incorporation of new procedures to reflect chang- ing technologies

Pennycook, Steve

47

Quality Assurance Plan for Heat Source/Radioisotope Thermoelectric Generator Programs  

SciTech Connect (OSTI)

The purpose of this document is to serve as the Quality Assurance Plan for Heat Source/Radioisotope Thermoelectric Generator (HS/RTG) programs performed at EG&G Mound Applied Technologies. As such, it identifies and describes the systems and activities in place to support the requirements contained in DOE Order 5700.6C as reflected in MD-10334, Mound Quality Policy and Responsibilities and the DOE/RPSD supplement, OSA/PQAR-1, Programmatic Quality Assurance Requirements for Space and Terrestrial Nuclear Power Systems. Unique program requirements, including additions, modifications, and exceptions to these quality requirements, are contained in the appendices of this plan. Additional appendices will be added as new programs and activities are added to Mound's HS/RTG mission assignment.

Gabriel, D. M.; Miller, G. D.; Bohne, W. A.

1995-03-16T23:59:59.000Z

48

Plutonium immobilization project development and testing quality assurance program description - February 1999  

SciTech Connect (OSTI)

Lawrence Livermore National Laboratory Immobilization Development and Testing organization (LLNL ID and T) is a Participant in the Plutonium Immobilization Project (PIP). The LLNL D and T has lead responsibilities for form characterization and qualification, ceramic form development, process/equipment development with plutonium, and process systems testing and validation for both conversion and immobilization. This work must be performed in accordance with the graded approach of a Quality Assurance (QA) Program. A QA Program has been developed at LLNL to meet the requirements of the DOE/MD Quality Assurance Requirements. The LLNL QA Program consists of a Quality Assurance Program Description (QAPD) and Quality Implementing Procedures. These documents interface and are a subset of the overall PIP QA Program Documents. The PIP QA Program is described in the PIP ID and T QA Plan, PIP QAPD, and QA Procedures. Other Participant Organizations also must document and describe their PIP compliant QA Programs in a QAPD and implementing procedures. The purpose of this LLNL QAPD is to describe the organization, management processes, QA Controls for Grading, functional responsibilities, levels of authority, and interfaces for those managing, performing, and assessing the adequacy of work.

MacLean, L M; Ziemba, J

1999-02-01T23:59:59.000Z

49

Quality Assurance Program Plan (QAPP) Waste Management Project  

SciTech Connect (OSTI)

The Waste Management Project (WMP) is committed to excellence in our work and to delivering quality products and services to our customers, protecting our employees and the public and to being good stewards of the environment. We will continually strive to understand customer requirements, perform services, and activities that meet or exceed customer expectations, and be cost-effective in our performance. The WMP maintains an environment that fosters continuous improvement in our processes, performance, safety and quality. The achievement of quality will require the total commitment of all WMP employees to our ethic that Quality, Health and Safety, and Regulatory Compliance must come before profits. The successful implementation of this policy and ethic requires a formal, documented management quality system to ensure quality standards are established and achieved in all activities. The following principles are the foundation of our quality system. Senior management will take full ownership of the quality system and will create an environment that ensures quality objectives are met, standards are clearly established, and performance is measured and evaluated. Line management will be responsible for quality system implementation. Each organization will adhere to all quality system requirements that apply to their function. Every employee will be responsible for their work quality, to work safely and for complying with the policies, procedures and instructions applicable to their activities. Quality will be addressed and verified during all phases of our work scope from proposal development through closeout including contracts or projects. Continuous quality improvement will be an ongoing process. Our quality ethic and these quality principles constantly guide our actions. We will meet our own quality expectations and exceed those of our customers with vigilance, commitment, teamwork, and persistence.

HORHOTA, M.J.

2000-12-21T23:59:59.000Z

50

Quality Assurance Guide for Project Management  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Guide provides acceptable approaches for implementing the Quality Assurance requirements and criteria of DOE O 413.3A related to the development and implementation of a Quality Assurance Program for the project. No cancellations.

2008-06-27T23:59:59.000Z

51

QUALITY ASSURANCE PROGRAM 1997 BNL Site Environmental Report 10 -1  

E-Print Network [OSTI]

, and improve implementation of the Division- wide QA program. 10.1 Environmental Surveillance Program The QA- prehensive QA program and are subject to audits by ES&HS Division personnel to ensure its implementation Management (QM) Office, headed by the QM Manager, coordinates and evaluates QA implementation

52

Quality Assurance 8-1 8. Quality Assurance  

E-Print Network [OSTI]

of a well-designed and well-implemented sampling and analysis program is to measure accurately what assurance/quality control (QA/QC) program for environmental monitoring activities at the ORR is essential Martin analytical laboratories have well-established QA/QC programs, well- trained and highly qualified

Pennycook, Steve

53

Software quality assurance handbook  

SciTech Connect (OSTI)

There are two important reasons for Software Quality Assurance (SQA) at Allied-Signal Inc., Kansas City Division (KCD): First, the benefits from SQA make good business sense. Second, the Department of Energy has requested SQA. This handbook is one of the first steps in a plant-wide implementation of Software Quality Assurance at KCD. The handbook has two main purposes. The first is to provide information that you will need to perform software quality assurance activities. The second is to provide a common thread to unify the approach to SQA at KCD. 2 figs.

Not Available

1990-09-01T23:59:59.000Z

54

Factors affecting binder properties between production and construction and their impact on quality assurance programs  

E-Print Network [OSTI]

FACTORS AFFECTING BINDER PROPERTIES BETWEEN PRODUCTION AND CONSTRUCTION AND THEIR IMPACT ON QUALITY ASSURANCE PROGRAMS A Thesis by EDITH ARAMBULA MERCADO Submitted to the Office of Graduate Studies of Texas A&M University in partial... ARAMBULA MERCADO Submitted to Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE Approved as to style and content by: Am Epps Martin (Chair of Committee) Roger ith (Member) l'Cl(fford Spiegelman...

Arambula Mercado, Edith

2002-01-01T23:59:59.000Z

55

Software Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

DOE N 251.40, dated 5/3/01, extends this directive until 12/31/01. To define requirements and responsibilities for software quality assurance (SQA) within the Department of Energy (DOE). Does not cancel other directives.

2000-10-02T23:59:59.000Z

56

Software Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To define requirements and responsibilities for software quality assurance (SQA) within the Department of Energy (DOE). DOE N 251.40, dated 5/3/01, extends this directive until 12/31/01.

2000-10-02T23:59:59.000Z

57

QUALITY ASSURANCE EXCHANGE December 2005 Volume 1 Issue 3  

Broader source: Energy.gov [DOE]

QUALITY ASSURANCE EXCHANGE December 2005 Volume 1 Issue 3 U.S. Department of Energy, Office of Corporate Performance Assessment Office of Quality Assurance Programs (EH-31)

58

Quality Assurance Exchange March 2006, Volume 2 Issue 1  

Broader source: Energy.gov [DOE]

Quality Assurance Exchange March 2006, Volume 2 Issue 1 U.S. Department of Energy, Office of Corporate Performance Assessment Office of Quality Assurance Programs (EH-31)

59

Quality Assurance Specialist (Safety Software Qualtiy Assurance)  

Broader source: Energy.gov [DOE]

A successful candidate in this position performs safety software quality assurance oversight of all activities that support the Waste Isolation Pilot Plant (WIPP) compliance with environmental,...

60

Management and overview Quality Assurance Program Plan. [Uranium Mill Tailings Remedial Action (UMTRA) Project  

SciTech Connect (OSTI)

The Uranium Mill Tailings Remedial Action (UMTRA) Project Office (DOE/ UMTRA-PO) is the US Department of Energy (DOE) Albuquerque Operations Office (AL) organization charged with the responsibility of managing and coordinating the activities of the various participating organizations and support contractors working on the UMTRA Project. This Quality Assurance Program Plan (QAPP) describes how the DOE/UMTRA-PO, as assisted by the Technical Assistance Contractor (TAC), performs the quality assurance (QA) aspects of managing and coordinating UMTRA Project activities. This QAPP was developed to comply with DOE Order 5700.6A, August, 1981, and AL Order 5700.6B, April, 1984, which contain the criteria applicable to Project QA activities.

Not Available

1986-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Implementation of an Integrated Quality Assurance Program for a CT-TPS Process.  

E-Print Network [OSTI]

??Systematic constancy and accuracy of a treatment planning system (TPS) are crucial for the entire radiation treatment planning process (TPP). The Quality Assurance (QA) of… (more)

Wu, Junqing

2002-01-01T23:59:59.000Z

62

Quality assurance and data management  

SciTech Connect (OSTI)

This report contains graphs and tables relating to quality assurance and data management for environmental quality at Hanford Reservation.

Lockrem, L.L.

1998-01-12T23:59:59.000Z

63

Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Quality Assurance Manual  

SciTech Connect (OSTI)

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment using a personal computer running the Microsoft Windows operating system. SAPHIRE is primarily funded by the U.S. Nuclear Regulatory Commission (NRC). The role of the INL in this project is that of software developer and tester. This development takes place using formal software development procedures and is subject to quality assurance (QA) processes. The purpose of this document is to describe how the SAPHIRE software QA is performed for Version 6 and 7, what constitutes its parts, and limitations of those processes.

C. L. Smith; R. Nims; K. J. Kvarfordt; C. Wharton

2008-08-01T23:59:59.000Z

64

Waste Management Quality Assurance Plan  

SciTech Connect (OSTI)

The WMG QAP is an integral part of a management system designed to ensure that WMG activities are planned, performed, documented, and verified in a manner that assures a quality product. A quality product is one that meets all waste acceptance criteria, conforms to all permit and regulatory requirements, and is accepted at the offsite treatment, storage, and disposal facility. In addition to internal processes, this QA Plan identifies WMG processes providing oversight and assurance to line management that waste is managed according to all federal, state, and local requirements for waste generator areas. A variety of quality assurance activities are integral to managing waste. These QA functions have been identified in the relevant procedures and in subsequent sections of this plan. The WMG QAP defines the requirements of the WMG quality assurance program. These requirements are derived from Department of Energy (DOE) Order 414.1C, Quality Assurance, Contractor Requirements Document, the LBNL Operating and Assurance Program Plan (OAP), and other applicable environmental compliance documents. The QAP and all associated WMG policies and procedures are periodically reviewed and revised, as necessary, to implement corrective actions, and to reflect changes that have occurred in regulations, requirements, or practices as a result of feedback on work performed or lessons learned from other organizations. The provisions of this QAP and its implementing documents apply to quality-affecting activities performed by the WMG; WMG personnel, contractors, and vendors; and personnel from other associated LBNL organizations, except where such contractors, vendors, or organizations are governed by their own WMG-approved QA programs.

Waste Management Group

2006-08-14T23:59:59.000Z

65

[Uranium Mill Tailings Remedial Action Project Office Quality Assurance Program Plan]. Revision 4  

SciTech Connect (OSTI)

The Uranium Mill Tailings Remedial Action (UMTRA) Project was established to accomplish remedial actions at inactive uranium mill tailings sites in accordance with Public Law 95-604, the Uranium Mill Tailings Radiation Control Act of 1978 (UMTRCA). The UMTRA Project`s mission is to stabilize and control the residual radioactive materials at designated sites in a safe and environmentally sound manner so as to minimize or eliminate radiation health hazards to the public. The US Department of Energy (DOE) UMTRA Project Office (UMTRA PO) directs the overall project. Since these efforts may involve possible risks to public health and safety, a quality assurance (QA) program that conforms to the applicable criteria (set forth in the reference documents) has been established to control the quality of the work. This document, the Quality Assurance Program Plan (QAPP), brings into one document the essential criteria to be applied on a selective basis, depending upon the nature of the activity being conducted, and describes how those criteria shall be applied to the UMTRA Project. The UMTRA PO shall require each Project contractor to prepare and submit for approval a more detailed QAPP that is based on the applicable criteria of this QAPP and the referenced documents. All QAPPs on the UMTRA Project shall fit within the framework of this plan.

Not Available

1992-06-01T23:59:59.000Z

66

[Uranium Mill Tailings Remedial Action Project Office Quality Assurance Program Plan  

SciTech Connect (OSTI)

The Uranium Mill Tailings Remedial Action (UMTRA) Project was established to accomplish remedial actions at inactive uranium mill tailings sites in accordance with Public Law 95-604, the Uranium Mill Tailings Radiation Control Act of 1978 (UMTRCA). The UMTRA Project's mission is to stabilize and control the residual radioactive materials at designated sites in a safe and environmentally sound manner so as to minimize or eliminate radiation health hazards to the public. The US Department of Energy (DOE) UMTRA Project Office (UMTRA PO) directs the overall project. Since these efforts may involve possible risks to public health and safety, a quality assurance (QA) program that conforms to the applicable criteria (set forth in the reference documents) has been established to control the quality of the work. This document, the Quality Assurance Program Plan (QAPP), brings into one document the essential criteria to be applied on a selective basis, depending upon the nature of the activity being conducted, and describes how those criteria shall be applied to the UMTRA Project. The UMTRA PO shall require each Project contractor to prepare and submit for approval a more detailed QAPP that is based on the applicable criteria of this QAPP and the referenced documents. All QAPPs on the UMTRA Project shall fit within the framework of this plan.

Not Available

1992-06-01T23:59:59.000Z

67

RUNWAY OPERATIONAL QUALITY ASSURANCE  

E-Print Network [OSTI]

RUNWAY OPERATIONAL QUALITY ASSURANCE MELANIE BAKER, DARIC MEGERSA & ALFONSO PANLILIO Sponsors: Dr Vortex Separation Rule, for a homogeneous fleet mix, is determined by the time between arriving aircraft Occupancy (SRO) rule, for a non- homogeneous fleet mix, MTC= 3600/ [ROT] [ROT]= = i (pi *ROTi) ROT (in sec

68

U.S. Department of Energy, Carlsbad Area Office quality assurance program document. Revision 1  

SciTech Connect (OSTI)

Mission of the Carlsbad Area Office (CAO) is to protect human health and the environment by opening and operating the Waste Isolation Pilot Plant (WIPP) for safe disposal of TRU waste, and establishing an effective system for management of TRU waste from generation to disposal. To help in fulfilling this mission and to ensure that risks and environmental impacts are identified and minimized, and that safety, reliability, and performance are optimized, CAO`s policy is to establish and maintain an effective quality assurance (QA) program that supports compliance with applicable Federal, State, and local regulations, and DOE orders and requirements. This document establishes QA program requirements for all programs, projects, and activities sponsored by CAO.

NONE

1996-04-01T23:59:59.000Z

69

Quality Assurance Exchange April 2009, Volume 5 Issue 1  

Broader source: Energy.gov [DOE]

Quality Assurance ExchangeA pril 2009, Volume 5 Issue 1 U.S. Department of Energy Office of Quality Assurance Policy and Assistance IN THE SPOTLIGHT: GEORGE DETSIS, PROGRAM MANAGER Analytical Services Program Office of Corporate Safety Programs

70

Software Quality Assurance Subcommittee : Guidelines for Requirements...  

Broader source: Energy.gov (indexed) [DOE]

Software Quality Assurance Subcommittee : Guidelines for Requirements Management Software Quality Assurance Subcommittee : Guidelines for Requirements Management Requirements...

71

Used Fuel Disposition Campaign Preliminary Quality Assurance...  

Energy Savers [EERE]

Used Fuel Disposition Campaign Preliminary Quality Assurance Implementation Plan Used Fuel Disposition Campaign Preliminary Quality Assurance Implementation Plan The primary...

72

Quality Assurance Corporate Board | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Assurance Corporate Board Quality Assurance Corporate Board The Office of Environmental Management (EM) Quality Assurance Corporate Board is an executive board that includes both...

73

Quality Assurance | Jefferson Lab  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert Southwest RegionatSearch Welcome to theNewsCenter forQuality Assurance Is A Key Focus

74

Data Driven Quality Assurance and Quality Control  

Broader source: Energy.gov [DOE]

"Data Driven Quality Assurance & Quality Control," Patrick Roche, Conservation Services Group. Provides an overview of data QA/QC system design.

75

Quality Assurance Exchange, January 2007  

Broader source: Energy.gov (indexed) [DOE]

third article of this series (Quality Assurance Exchange June, volume 2, Issue 2), the bulk of the comments derived from the factual accuracy review should be editorial. When...

76

Quality Assurance Exchange August 2011  

Office of Environmental Management (EM)

Editor: Debbie Rosano: 301-903-8177, debbie.rosano@hq.doe.gov Quality Assurance Web site: www.hss.energy.govnuclearsafetyqa Questions or Comments? Please submit to...

77

International Quality Assurance Standards (Presentation)  

SciTech Connect (OSTI)

Tests to make quantitative predictions about photovoltaic (PV) modules are needed. This presentation proposes the creation of international quality assurance standards for PV modules.

Kurtz, S.; Hacke, P.; Wohlgemuth, J.; Kempe, M.; Yamamichi, M.

2011-02-01T23:59:59.000Z

78

Quality Assurance Exchange, March 2006  

Broader source: Energy.gov (indexed) [DOE]

on Performing Assessments: Auditing Tools & Techniques 1 Lessons Learned: Quality Assurance Related to Fastener Torque Requirements 2 Washington Closure Hanford Safety Software...

79

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM | Department of...  

Broader source: Energy.gov (indexed) [DOE]

PROGRAM SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM Training Checklist SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM More Documents & Publications Quality Assurance Checklist...

80

Construction quality assurance report  

SciTech Connect (OSTI)

This report provides a summary of the construction quality assurance (CQA) observation and test results, including: The results of the geosynthetic and soil materials conformance testing. The observation and testing results associates with the installation of the soil liners. The observation and testing results associated with the installation of the HDPE geomembrane liner systems. The observation and testing results associated with the installation of the leachate collection and removal systems. The observation and testing results associated with the installation of the working surfaces. The observation and testing results associated with in-plant manufacturing process. Summary of submittal reviews by Golder Construction Services, Inc. The submittal and certification of the piping material specifications. The observation and verification associated of the Acceptance Test Procedure results of the operational equipment functions. Summary of the ECNs which are incorporated into the project.

Roscha, V.

1994-09-08T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Final Report Project Activity Task ORD-FY04-002 Nevada System of Higher Education Quality Assurance Program  

SciTech Connect (OSTI)

The principal purpose of DOE Cooperative Agreement DE-FC28-04RW12232 is to develop and continue providing the public and the U.S. Department of Energy’s (DOE) Office of Civilian Radioactive Waste Management (OCRWM) with an independently derived, unbiased body of scientific and engineering data concerning the study of Yucca Mountain as a potential high-level radioactive waste repository. Under this agreement, the Nevada System of Higher Education (NSHE), formerly the University and Community College System of Nevada (UCCSN), performs scientific or engineering research, and maintains and fosters collaborative working relationships between government and academic researchers. In performing these activities, the NSHE has already developed and implemented a Quality Assurance (QA) program, which was accepted by the DOE Office of Quality Assurance, under the previous Cooperative Agreement Number DE-FC28-98NV12081. The following describes the objectives of Project Activity 002 “Quality Assurance Program” under cooperative agreement DE-FC28-04RW12232. The objective of this QA program was to assure that data produced under the cooperative agreement met the OCRWM QA Requirements and Description (QARD) requirements for quality-affecting (Q) data. The QA Program was written to address specific QARD requirements historically identified and incorporated in Q activities to the degree appropriate for the nature, scope, and complexity of the activity. Additional QARD requirements were integrated into the program when required to complete a specific activity. NSHE QA staff developed a detailed matrix to address each QARD element, identifying the applicable requirements and specifying where each requirement is addressed in the QA program procedures, or identify requirements as “not applicable” to the QA program. Controlled documents were prepared in the form of QA procedures (QAPs) and implementing procedures (IPs). NSHE identified new QAPs and IPs when needed. NSHE PIs implemented the QA program and completed individual research project activities. PIs were also responsible for developing implementing procedures, conducting technical training, assuring that the QA program training was acquired by all task personnel, and participating in monitoring the QA program control for each individual research project activity. This project activity, which was an essential part of the program to enhance the collaborative ongoing research between the NSHE and ORD, was intended to support all quality-affecting activities funded during the five-year period of the cooperative agreement. However, the cooperative agreement was down-graded to non quality-affecting after 4 years.

Smiecinski, Amy; Keeler, Raymond; Bertoia, Julie; Mueller, Terry; Roosa, Morris; Roosa, Barbara

2008-03-07T23:59:59.000Z

82

Quality assurance of HDR prostate plans: Program implementation at a community hospital  

SciTech Connect (OSTI)

Adenocarcinoma of the prostate is currently the most commonly diagnosed cancer in men in the United States, and the second leading cause of cancer mortality. The utilization of radiation therapy is regarded as the definitive local therapy of choice for intermediate- and high-risk disease, in which there is increased risk for extracapsular extension, seminal vesicle invasion, or regional node involvement. High-dose-rate (HDR) brachytherapy is a logical treatment modality to deliver the boost dose to an external beam radiation therapy (EBRT) treatment to increase local control rates. From a treatment perspective, the utilization of a complicated treatment delivery system, the compressed time frame in which the procedure is performed, and the small number of large dose fractions make the implementation of a comprehensive quality assurance (QA) program imperative. One aspect of this program is the QA of the HDR treatment plan. Review of regulatory and medical physics professional publications shows that substantial general guidance is available. We provide some insight to the implementation of an HDR prostate plan program at a community hospital. One aspect addressed is the utilization of the low-dose-rate (LDR) planning system and the use of existing ultrasound image sets to familiarize the radiation therapy team with respect to acceptable HDR implant geometries. Additionally, the use of the LDR treatment planning system provided a means to prospectively determine the relationship between the treated isodose volume and the product of activity and time for the department's planning protocol prior to the first HDR implant. For the first 12 HDR prostate implants, the root-mean-square (RMS) deviation was 3.05% between the predicted product of activity and time vs. the actual plan values. Retrospective re-evaluation of the actual implant data reduced the RMS deviation to 2.36%.

Rush, Jennifer B. [Department of Radiation Oncology, High Point Regional Hospital, High Point, NC (United States); Thomas, Michael D. [Department of Radiation Oncology, High Point Regional Hospital, High Point, NC (United States)]. E-mail: mthomas@hprhs.com

2005-01-01T23:59:59.000Z

83

SAPHIRE 8 Software Quality Assurance Oversight  

SciTech Connect (OSTI)

The software quality assurance oversight consists of updating and maintaining revision control of the SAPHIRE 8 quality assurance program documentation and of monitoring revision control of the SAPHIRE 8 source code. This report summarizes the oversight efforts through description of the revision control system (RCS) setup, operation and contents. Documents maintained under revision control include the Acceptance Test Plan (ATP), Configuration Management Plan, Quality Assurance Plan, Software Project Plan, Requirements Traceability Matrix (RTM), System Test Plan, SDP Interface Training Manual, and the SAPHIRE 8, 'New Features and Capabilities Overview'.

Kurt G. Vedros

2011-09-01T23:59:59.000Z

84

QUALITY ASSURANCE/QUALITY CONTROL MANUAL FOR THE LOWER CAPE FEAR RIVER PROGRAM  

E-Print Network [OSTI]

Operating Procedures for Field Sampling..........................7 7 Chain of Custody Maintenance and Calibration" to "Multi-Parameter Water Quality Meter Operation". Page 1 - Introduction............................................................................1 5 Station Descriptions and Sampling Schedule.................................3 6 Standard

Mallin, Michael

85

Quality assurance for gamma knives  

SciTech Connect (OSTI)

This report describes and summarizes the results of a quality assurance (QA) study of the Gamma Knife, a nuclear medical device used for the gamma irradiation of intracranial lesions. Focus was on the physical aspects of QA and did not address issues that are essentially medical, such as patient selection or prescription of dose. A risk-based QA assessment approach was used. Sample programs for quality control and assurance are included. The use of the Gamma Knife was found to conform to existing standards and guidelines concerning radiation safety and quality control of external beam therapies (shielding, safety reviews, radiation surveys, interlock systems, exposure monitoring, good medical physics practices, etc.) and to be compliant with NRC teletherapy regulations. There are, however, current practices for the Gamma Knife not covered by existing, formalized regulations, standards, or guidelines. These practices have been adopted by Gamma Knife users and continue to be developed with further experience. Some of these have appeared in publications or presentations and are slowly finding their way into recommendations of professional organizations.

Jones, E.D.; Banks, W.W.; Fischer, L.E. [Lawrence Livermore National Lab., CA (United States)

1995-09-01T23:59:59.000Z

86

Highly Integrated Quality Assurance – An Empirical Case  

SciTech Connect (OSTI)

Highly Integrated Quality Assurance – An Empirical Case Drake Kirkham1, Amy Powell2, Lucas Rich3 1Quality Manager, Radioisotope Power Systems (RPS) Program, Idaho National Laboratory, P.O. Box 1625 M/S 6122, Idaho Falls, ID 83415-6122 2Quality Engineer, RPS Program, Idaho National Laboratory 3Quality Engineer, RPS Program, Idaho National Laboratory Contact: Voice: (208) 533-7550 Email: Drake.Kirkham@inl.gov Abstract. The Radioisotope Power Systems Program of the Idaho National Laboratory makes an empirical case for a highly integrated Quality Assurance function pertaining to the preparation, assembly, testing, storage and transportation of 238Pu fueled radioisotope thermoelectric generators. Case data represents multiple campaigns including the Pluto/New Horizons mission, the Mars Science Laboratory mission in progress, and other related projects. Traditional Quality Assurance models would attempt to reduce cost by minimizing the role of dedicated Quality Assurance personnel in favor of either functional tasking or peer-based implementations. Highly integrated Quality Assurance adds value by placing trained quality inspectors on the production floor side-by-side with nuclear facility operators to enhance team dynamics, reduce inspection wait time, and provide for immediate, independent feedback. Value is also added by maintaining dedicated Quality Engineers to provide for rapid identification and resolution of corrective action, enhanced and expedited supply chain interfaces, improved bonded storage capabilities, and technical resources for requirements management including data package development and Certificates of Inspection. A broad examination of cost-benefit indicates highly integrated Quality Assurance can reduce cost through the mitigation of risk and reducing administrative burden thereby allowing engineers to be engineers, nuclear operators to be nuclear operators, and the cross-functional team to operate more efficiently. Applicability of this case extends to any high-value, long-term project where traceability and accountability are determining factors.

Drake Kirkham; Amy Powell; Lucas Rich

2011-02-01T23:59:59.000Z

87

Quality Assurance: Are Laboratories Assuring, Assessing, or Assuming the Quality of Clinical Testing Today?  

E-Print Network [OSTI]

Abstract: Quality assurance implies making certain, guaranteeing the attainment of quality. Do laboratories actually guarantee the quality of testing services today? If not, what is the purpose of quality assurance plans, programs, and practices? Have laboratories even defined the quality to be achieved for each test? If not, how can quality be guaranteed? Do current efforts in assessing quality provide for real-time control that will guarantee quality? If not, are laboratories just assuming that measuring quality will somehow make it happen? Even analytical quality, which is fundamental for the core production processes of any laboratory, is mainly assessed and assumed, not assured. Problems include the lack of well defined quality requirements, inadequate method performance, poorly designed statistical control procedures, misguided quality control instructions and recommendations, insufficient technical quality management skills, reduced operator skills, and delays in implementing of laboratory regulations. Quality assurance should be understood, not as a component, but as the outcome of a quality management process that includes quality planning, quality laboratory practices, quality control, quality assessment, and quality improvement, all linked together and guided by quality goals and customer requirements, and applied to the total testing process. In the future, automation and computerization will be necessary to manage the quality of centralized and distributed laboratory testing. Analytical quality will be guaranteed through on-line or on-board quality control. Other critical quality characteristics will need real-time monitors and control mechanisms to guarantee quality if process failures cannot be prevented.

James O. Westgard, Ph.D.

88

Quality Assurance Exchange, October 2008  

Broader source: Energy.gov (indexed) [DOE]

do not reflect the current operating organization. 6. Based on the number and nature of the findings for this audit, it is evident the Quality Assurance Department is not...

89

Emergency Readiness Assurance Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To establish the requirements of the Emergency Readiness Assurance Program with a goal of assurting that the Department of Energy (DOE) Emergency Management System (EMS) is ready to respond promptly, efficiently, and effectively to any emergency involving DOE facilities or requiring DOE assistance. Cancels DOE O 5500.10 dated 4-30-91. Chg 1 dated 2-27-92. Change 1 canceled by DOE O 151.1 of 9-25-95.

1992-02-27T23:59:59.000Z

90

Applications of program understanding and rule-based quality assurance to Slam II simulation programs.  

E-Print Network [OSTI]

??With the advance of time, our inventory of simulation programs has and continues to accumulate. To maximize the return on our investment of time and… (more)

Wendt, N. Rodney.

2009-01-01T23:59:59.000Z

91

Surveillance Guides - QAS 2.6 Quality Assurance Records  

Broader source: Energy.gov (indexed) [DOE]

is to evaluate the effectiveness of the contractor's implementation of the program to identify, collect and maintain quality assurance records. The surveillance...

92

Quality Assurance Source Requirements Traceability Database  

SciTech Connect (OSTI)

At the Yucca Mountain Project the Project Requirements Processing System assists in the management of relationships between regulatory and national/industry standards source criteria, and Quality Assurance Requirements and Description document (DOE/R W-0333P) requirements to create compliance matrices representing respective relationships. The matrices are submitted to the U.S. Nuclear Regulatory Commission to assist in the commission's review, interpretation, and concurrence with the Yucca Mountain Project QA program document. The tool is highly customized to meet the needs of the Office of Civilian Radioactive Waste Management Office of Quality Assurance.

MURTHY, R., NAYDENOVA, A., DEKLEVER, R., BOONE, A.

2006-01-30T23:59:59.000Z

93

Quality assurance manual: Volume 1  

SciTech Connect (OSTI)

Stanford Linear Accelerator Center (SLAC) is a DOE-supported research facility that carries out experimental and theoretical research in high energy physics and developmental work in new techniques for particle acceleration and experimental instrumentation. The purpose of this manual is to describe SLAC quality assurance policies and practices in various parts of the Laboratory.

Oijala, J.E.

1988-06-01T23:59:59.000Z

94

A Basic Guide to EM's Quality Assurance Program | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energyon ArmedWaste and Materials2014 Chief FreedomServices » Program Management » Quality

95

Report: EM Quality Assurance  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power.pdf11-161-LNG |September 15,2015Department of Energy onACQUISITION ANDEMEM QUALITY

96

Section 22: Quality Assurance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administrationcontroller systemsBi (2) Sr (2)ScienceScientistsONDelivered5 Figurem DFigure9Quality

97

The Waste Management Quality Assurance Implementing Management Plan (QAIMP)  

E-Print Network [OSTI]

DIVISION Waste Management Quality Assurance ImplementingI I IMPLEMENTING MANAGEMENT QUALITY PLAN ASSURANCE I lilillI WM-QAIMP Waste Management Quality Assurance Implementing

Albert editor, R.

2009-01-01T23:59:59.000Z

98

Fuel Efficiency Automobile Test Quality Assurance Narrative  

E-Print Network [OSTI]

Fuel Efficiency Automobile Test Quality Assurance Narrative Standard Operating Procedures Help ........................................................................................................... 3 FEAT Standard Operating Procedures...................................................................................................................24 Maintenance Items

Denver, University of

99

Chemical analysis quality assurance at the ICPP  

SciTech Connect (OSTI)

This document discusses the chemical analysis quality assurance program at the ICPP which involves records management, analytical methods quality control, analysis procedures and training and qualification. Since 1979, the major portion of the quality assurance program has been implemented on a central analytical computer system. The individual features provided by the system are storage, retrieval, and search capabilities over all general request and sample analysis information, automatic method selection for all process streams, automation of all method calculations, automatic assignment of bias and precision estimates at all analysis levels, with-method-use requalification, untrained or unqualified analyst method lockout, statistical testing of all process stream results for replicate agreement, automatic testing of process results against pre- established operating, safety, or failure limits at varying confidence levels, and automatic transfer and report of all analysis data plus all statistical testing to the Production Department.

Hand, R.L.

1990-01-01T23:59:59.000Z

100

Chemical analysis quality assurance at the ICPP  

SciTech Connect (OSTI)

This document discusses the chemical analysis quality assurance program at the ICPP which involves records management, analytical methods quality control, analysis procedures and training and qualification. Since 1979, the major portion of the quality assurance program has been implemented on a central analytical computer system. The individual features provided by the system are storage, retrieval, and search capabilities over all general request and sample analysis information, automatic method selection for all process streams, automation of all method calculations, automatic assignment of bias and precision estimates at all analysis levels, with-method-use requalification, untrained or unqualified analyst method lockout, statistical testing of all process stream results for replicate agreement, automatic testing of process results against pre- established operating, safety, or failure limits at varying confidence levels, and automatic transfer and report of all analysis data plus all statistical testing to the Production Department.

Hand, R.L.

1990-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Quality assurance in small plating shops  

SciTech Connect (OSTI)

The potential for electroless nickel coatings in oilfield and petrochemical applications is quite high. The greatest obstacle to their use has been a reputation for poor quality due to a lack of quality control in many plating shops. To overcome this, electroless nickel shops should not only have a quality control program in their operation, but must also document its use and success. This article describes how a plating shoe can develop the necessary procedures, manuals, and paperwork trail to offer quality assurance and to satisfy customers.

McNabb, W.J. (Electroless Nickel Plating of Louisiana, Hammond, LA (United States))

1993-10-01T23:59:59.000Z

102

222-S Laboratory Quality Assurance Plan. Revision 1  

SciTech Connect (OSTI)

This Quality Assurance Plan provides,quality assurance (QA) guidance, regulatory QA requirements (e.g., 10 CFR 830.120), and quality control (QC) specifications for analytical service. This document follows the U.S Department of Energy (DOE) issued Hanford Analytical Services Quality Assurance Plan (HASQAP). In addition, this document meets the objectives of the Quality Assurance Program provided in the WHC-CM-4-2, Section 2.1. Quality assurance elements required in the Guidelines and Specifications for Preparing Quality Assurance Program Plans (QAMS-004) and Interim Guidelines and Specifications for Preparing Quality Assurance Project Plans (QAMS-005) from the US Environmental Protection Agency (EPA) are covered throughout this document. A quality assurance index is provided in the Appendix A. This document also provides and/or identifies the procedural information that governs laboratory operations. The personnel of the 222-S Laboratory and the Standards Laboratory including managers, analysts, QA/QC staff, auditors, and support staff shall use this document as guidance and instructions for their operational and quality assurance activities. Other organizations that conduct activities described in this document for the 222-S Laboratory shall follow this QA/QC document.

Meznarich, H.K.

1995-07-31T23:59:59.000Z

103

Quality Assurance/Quality Control (QA/QC) Summary for the California Rivers and Streams Study  

E-Print Network [OSTI]

APPENDIX 1 Quality Assurance/Quality Control (QA/QC) Summary for the California Rivers and Streams Ambient Monitoring Program (SWAMP) Quality Assurance Program Plan (QAPrP) are outlined in the Rivers QAPP may arise so that corrective actions can be implemented. Quality control samples prepared and analyzed

104

Quality Assurance | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems Engineering Research and DevelopmentDepartmentin DesignQuality Assurance forQuality

105

Quality Assurance | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems Engineering Research and DevelopmentDepartmentin DesignQuality Assurance

106

Quality assurance manual: Volume 2, Appendices  

SciTech Connect (OSTI)

This paper contains quality assurance information on departments of the Stanford Linear Accelerator Center. Particular quality assurance policies and standards discussed are on: Mechanical Systems; Klystron and Microwave Department; Electronics Department; Plant Engineering; Accelerator Department; Purchasing; and Experimental Facilities Department. (LSP)

Oijala, J.E.

1988-06-01T23:59:59.000Z

107

Quality Assurance Management System Guide for Use with 10 CFR 830 Subpart A, Quality Assurance Requirements, and DOE O 414.1C, Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Guide provides information on principles and practices used to establish and implement an effective quality assurance program or quality management system in accordance with the requirements of 10 CFR 830. Cancels DOE G 414.1-2. Canceled by DOE G 414.1-2B.

2005-06-17T23:59:59.000Z

108

Operating and Assurance Program Plan. Revision 4  

SciTech Connect (OSTI)

The LBL Operating and Assurance Program (OAP) is a management system and a set of requirements designed to maintain the level of performance necessary to achieve LBL`s programmatic and administrative objectives effectively and safely through the application of quality assurance and related conduct of operations and maintenance management principles. Implement an LBL management philosophy that supports and encourages continual improvement in performance and quality at the Laboratory. Provide an integrated approach to compliance with applicable regulatory requirements and DOE orders. The OAP is intended to meet the requirements of DOE Order 5700.6C, Quality Assurance. The Program also contains management system elements of DOE Orders 5480.19, Conduct of Operations Requirements for DOE Facilities; 5480.25, Safety of Accelerator Facilities; and 4330.4A, Maintenance Management Program, and is meant to integrate these elements into the overall LBL approach to Laboratory management. The requirements of this program apply to LBL employees and organizations, and to contractors and facility users as managed by their LBL sponsors. They are also applicable to external vendors and suppliers as specified in procurement documents and contracts.

Not Available

1994-07-01T23:59:59.000Z

109

A Comprehensive Quality Assurance Program for Personnel and Procedures in Radiation Oncology: Value of Voluntary Error Reporting and Checklists  

SciTech Connect (OSTI)

Purpose: This report describes the value of a voluntary error reporting system and the impact of a series of quality assurance (QA) measures including checklists and timeouts on reported error rates in patients receiving radiation therapy. Methods and Materials: A voluntary error reporting system was instituted with the goal of recording errors, analyzing their clinical impact, and guiding the implementation of targeted QA measures. In response to errors committed in relation to treatment of the wrong patient, wrong treatment site, and wrong dose, a novel initiative involving the use of checklists and timeouts for all staff was implemented. The impact of these and other QA initiatives was analyzed. Results: From 2001 to 2011, a total of 256 errors in 139 patients after 284,810 external radiation treatments (0.09% per treatment) were recorded in our voluntary error database. The incidence of errors related to patient/tumor site, treatment planning/data transfer, and patient setup/treatment delivery was 9%, 40.2%, and 50.8%, respectively. The compliance rate for the checklists and timeouts initiative was 97% (P<.001). These and other QA measures resulted in a significant reduction in many categories of errors. The introduction of checklists and timeouts has been successful in eliminating errors related to wrong patient, wrong site, and wrong dose. Conclusions: A comprehensive QA program that regularly monitors staff compliance together with a robust voluntary error reporting system can reduce or eliminate errors that could result in serious patient injury. We recommend the adoption of these relatively simple QA initiatives including the use of checklists and timeouts for all staff to improve the safety of patients undergoing radiation therapy in the modern era.

Kalapurakal, John A., E-mail: j-kalapurakal@northwestern.edu [Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States); Zafirovski, Aleksandar; Smith, Jeffery; Fisher, Paul; Sathiaseelan, Vythialingam [Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States)] [Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States); Barnard, Cynthia [Department of Quality Strategies, Northwestern Memorial Hospital, Chicago, Illinois (United States)] [Department of Quality Strategies, Northwestern Memorial Hospital, Chicago, Illinois (United States); Rademaker, Alfred W. [Department of Preventive Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States)] [Department of Preventive Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States); Rave, Nick [Department of Physicians Services, Northwestern Memorial Hospital, Chicago, Illinois (United States)] [Department of Physicians Services, Northwestern Memorial Hospital, Chicago, Illinois (United States); Mittal, Bharat B. [Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States)] [Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, Illinois (United States)

2013-06-01T23:59:59.000Z

110

Office of Civilian Radioactive Waste Management-Quality Assurance...  

Office of Environmental Management (EM)

Office of Civilian Radioactive Waste Management-Quality Assurance Requirements and Description Office of Civilian Radioactive Waste Management-Quality Assurance Requirements and...

111

Quality Assurance Exchange August 2009, Volume 5 Issue 2  

Broader source: Energy.gov [DOE]

Quality Assurance Exchange August 2009, Volume 5 Issue 2 U.S. Department of Energy Office of Quality Assurance Policy and Assistance

112

CRAD, Quality Assurance - Oak Ridge National Laboratory TRU ALPHA...  

Broader source: Energy.gov (indexed) [DOE]

Quality Assurance - Oak Ridge National Laboratory TRU ALPHA LLWT Project CRAD, Quality Assurance - Oak Ridge National Laboratory TRU ALPHA LLWT Project November 2003 A section of...

113

NMMSS Software Quality Assurance Plan | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Quality Assurance Plan The Software Quality Assurance Plan (SQAP) for the Nuclear Materials Management and Safeguard System (NMMSS) software upgrade project (an actual DOE...

114

Quality Assurance Exchange Winter 2010 Volume 6 Issue 1  

Broader source: Energy.gov [DOE]

Quality Assurance Exchange Winter 2010 Volume 6 Issue 1 U.S. Department of Energy Office of Quality Assurance Policy and Assistance

115

Quality Assurance Exchange October 2008 Volume 4 Issue 2  

Broader source: Energy.gov [DOE]

Quality Assurance Exchange October 2008 Volume 4 Issue 2 U.S. Department of Energy Office of Quality Assurance Policy and Assistance

116

2011 SAPHIRE 8 Software Quality Assurance Status Report  

SciTech Connect (OSTI)

The Software Quality Assurance engineer position was created in fiscal year 2011 to better maintain and improve the quality of the SAPHIRE 8 development program. This year's Software Quality Assurance tasks concentrated on developing the framework of the SQA program. This report reviews the accomplishments and recommendations for each of the subtasks set forth for JCN V6059: (1) Reviews, Tests, and Code Walkthroughs; (2) Data Dictionary; (3) Metrics; (4) Requirements Traceability Matrix; (5) Provide Oversight on SAPHIRE QA Activities; and (6) Support NRC Presentations and Meetings.

Kurt G. Vedros

2011-09-01T23:59:59.000Z

117

FAQS Reference Guide – Safety Software Quality Assurance  

Broader source: Energy.gov [DOE]

This reference guide has been developed to address the competency statements in the (March 2011) edition of DOE-STD-1172-2011, Safety Software Quality Assurance Functional Area Qualification Standard.

118

QUALITY ASSURANCE MANUAL Revised March 2009  

E-Print Network [OSTI]

. Guidelines 4-7 III. Standards of Care 8 IV. Standard of Care by Discipline Dental Hygiene 9 Endodontics 10 set forth in that paper. Quality assessment is a measure of quality and is a continuing function;GUIDELINES The following guidelines shall serve to guide the Quality Assurance Committee in the performance

119

E-Print Network 3.0 - assurance testing program Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Search Sample search results for: assurance testing program Page: << < 1 2 3 4 5 > >> 1 CSP 587: Software Quality Management S. Kan, Software Quality engineering, Addison-Wesley....

120

NIF Projects Controls and Information Systems Software Quality Assurance Plan  

SciTech Connect (OSTI)

Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

Fishler, B

2011-03-18T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Hanford analytical services quality assurance requirements documents  

SciTech Connect (OSTI)

Hanford Analytical Services Quality Assurance Requirements Document (HASQARD) is issued by the Analytical Services, Program of the Waste Management Division, US Department of Energy (US DOE), Richland Operations Office (DOE-RL). The HASQARD establishes quality requirements in response to DOE Order 5700.6C (DOE 1991b). The HASQARD is designed to meet the needs of DOE-RL for maintaining a consistent level of quality for sampling and field and laboratory analytical services provided by contractor and commercial field and laboratory analytical operations. The HASQARD serves as the quality basis for all sampling and field/laboratory analytical services provided to DOE-RL through the Analytical Services Program of the Waste Management Division in support of Hanford Site environmental cleanup efforts. This includes work performed by contractor and commercial laboratories and covers radiological and nonradiological analyses. The HASQARD applies to field sampling, field analysis, and research and development activities that support work conducted under the Hanford Federal Facility Agreement and Consent Order Tri-Party Agreement and regulatory permit applications and applicable permit requirements described in subsections of this volume. The HASQARD applies to work done to support process chemistry analysis (e.g., ongoing site waste treatment and characterization operations) and research and development projects related to Hanford Site environmental cleanup activities. This ensures a uniform quality umbrella to analytical site activities predicated on the concepts contained in the HASQARD. Using HASQARD will ensure data of known quality and technical defensibility of the methods used to obtain that data. The HASQARD is made up of four volumes: Volume 1, Administrative Requirements; Volume 2, Sampling Technical Requirements; Volume 3, Field Analytical Technical Requirements; and Volume 4, Laboratory Technical Requirements. Volume 1 describes the administrative requirements applicable to each of the other three volumes and is intended to be used in conjunction with the technical volumes.

Hyatt, J.E.

1997-09-25T23:59:59.000Z

122

SAPHIRE 8 Volume 6 - Quality Assurance  

SciTech Connect (OSTI)

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Version 8 is a software application developed for performing a complete probabilistic risk assessment using a personal computer running the Microsoft Windows™ operating system. SAPHIRE 8 is funded by the U.S. Nuclear Regulatory Commission (NRC). The role of the INL in this project is that of software developer and tester. This development takes place using formal software development procedures and is subject to quality assurance (QA) processes. The purpose of this document is to describe how the SAPHIRE software QA is performed for Version 8, what constitutes its parts, and limitations of those processes. In addition, this document describes the Independent Verification and Validation that was conducted for Version 8 as part of an overall QA process.

C. L. Smith; R. Nims; K. J. Kvarfordt

2011-03-01T23:59:59.000Z

123

The Groundwater Performance Assessment Project Quality Assurance Plan  

SciTech Connect (OSTI)

This document provides the quality assurance guidelines that will be followed by the groundwater project.

Walker, Thomas G.

2005-01-26T23:59:59.000Z

124

Legacy Management CERCLA Sites. Quality Assurance Project Plan  

SciTech Connect (OSTI)

S.M. Stoller Corporation is the contractor for the Technical Assistance Contract (TAC) for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) operations. Stoller employs a management system that applies to all programs, projects, and business management systems funded through DOE-LM task orders. The management system incorporates the philosophy, policies, and requirements of health and safety, environmental compliance, and quality assurance (QA) in all aspects of project planning and implementation. Health and safety requirements are documented in the Health and Safety Manual (STO 2), the Radiological Control Manual (STO 3), the Integrated Safety Management System Description (STO 10), and the Drilling Health and Safety Requirements (STO 14). Environmental compliance policy and requirements are documented in the Environmental Management Program Implementation Manual (STO 11). The QA Program is documented in the Quality Assurance Manual (STO 1). The QA Manual (STO 1) implements the specific requirements and philosophy of DOE Order 414.1C, Quality Assurance. This manual also includes the requirements of other standards that are regularly imposed by customers, regulators, or other DOE orders. Title 10 Code of Federal Regulations Part 830, “Quality Assurance Requirements,” ANSI/ASQC E4-2004, “Quality Systems for Environmental Data and Technology Programs – Requirements with Guidance for Use,” and ISO 14001-2004, “Environmental Management Systems,” have been included. These standards are similar in content. The intent of the QA Manual (STO 1) is to provide a QA management system that incorporates the requirements and philosophy of DOE and other customers within the QA Manual. Criterion 1, “Quality Assurance Program,” identifies the fundamental requirements for establishing and implementing the QA management system; QA Instruction (QAI) 1.1, “QA Program Implementation,” identifies the TAC organizations that have responsibility for implementing the QA program requirements; and Appendix C of the QA Manual provides comparison tables that identify where the requirements of other standards are addressed in the QA Manual.

None

2007-05-03T23:59:59.000Z

125

Static and Dynamic Quality Assurance by Aspect Oriented Techniques  

E-Print Network [OSTI]

The overall goal of the described research project was to create applicable quality assurance patterns for Java software systems using the aspect-oriented programming language extension AspectJ 5. We tried to develop aspects to check static quality criteria as a variable mutator convention and architectural layering rules. We successfully developed aspects for automating the following dynamic quality criteria: Parameterized Exception Chaining, Comfortable Declaration of Parameterized Exceptions, Not-Null Checking of Reference Variables.

Knabe, Christoph

2010-01-01T23:59:59.000Z

126

Quality Assurance Exchange, June 2006  

Broader source: Energy.gov (indexed) [DOE]

EXCELLENCE Submitted by Julianna Gallego, Strategic Petroleum Reserve The ANSIISOASQ Q9001-2000 Figure 1. Model of process-based quality management system Meeting the...

127

Skoll: A Process and Infrastructure for Distributed Continuous Quality Assurance  

E-Print Network [OSTI]

-house QA is that programs can be analyzed at a fine level of detail since QA teams have extensive knowledge of potential system configurations built from rapidly changing component implementations. Since today's quality assurance (QA) techniques do not scale to handle highly configurable systems, we are developing

Memon, Atif M.

128

CRAD, Quality Assurance- Idaho MF-628 Drum Treatment Facility  

Broader source: Energy.gov [DOE]

A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for a May 2007 readiness assessment of the Quality Assurance Program at the Advanced Mixed Waste Treatment Project.

129

CRAD, Quality Assurance- Idaho Accelerated Retrieval Project Phase II  

Broader source: Energy.gov [DOE]

A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for a February 2006 Commencement of Operations assessment of the Quality Assurance Program at the Idaho Accelerated Retrieval Project Phase II.

130

The Groundwater Performance Assessment Project Quality Assurance Plan  

SciTech Connect (OSTI)

U.S. Department of Energy (DOE) has monitored groundwater on the Hanford Site since the 1940s to help determine what chemical and radiological contaminants have made their way into the groundwater. As regulatory requirements for monitoring increased in the 1980s, there began to be some overlap between various programs. DOE established the Groundwater Performance Assessment Project (groundwater project) in 1996 to ensure protection of the public and the environment while improving the efficiency of monitoring activities. The groundwater project is designed to support all groundwater monitoring needs at the site, eliminate redundant sampling and analysis, and establish a cost-effective hierarchy for groundwater monitoring activities. This document provides the quality assurance guidelines that will be followed by the groundwater project. This QA Plan is based on the QA requirements of DOE Order 414.1C, Quality Assurance, and 10 CFR 830, Subpart A--General Provisions/Quality Assurance Requirements as delineated in Pacific Northwest National Laboratory’s Standards-Based Management System. In addition, the groundwater project is subject to the Environmental Protection Agency (EPA) Requirements for Quality Assurance Project Plans (EPA/240/B-01/003, QA/R-5). The groundwater project has determined that the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD, DOE/RL-96-68) apply to portions of this project and to the subcontractors. HASQARD requirements are discussed within applicable sections of this plan.

Luttrell, Stuart P.

2006-05-11T23:59:59.000Z

131

Quality Assurance Exchange, Winter 2010  

Office of Environmental Management (EM)

task of the ten quality criteria listed within 10 CFR 830 Subpart A 1 and DOE Order 414.1C 2 because of the many complexities and abstractions associated with design, and...

132

DOE Order on Quality Assurance  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Deliciouscritical_materials_workshop_presentations.pdf MoreProgram |DOEInfrastructure Working420.1B FACILITY

133

The development of the quality assurance program for PM2.5: The December 13, 1996 proposal, the July 18, 1997 regulations and the public comments concerning QA  

SciTech Connect (OSTI)

The Environmental Protection Agency (EPA) has developed a new National Ambient Air Quality Standard (NAAQS) standard for particles in the atmosphere with aerometric diameters of 2.5 micrometers or less. The EPA has also promulgated a new federal reference and equivalent method program to regulate the methods needed to monitor these particles. This federal reference method (FRM) is very complex and sensitive and requires enhanced quality assurance (QA) and quality control (QC) procedures to ensure that a valid sample is collected. The QA program for PM2.5 was first introduced in the December 13, 1996 proposal published in the Federal Register. This proposal outlined several QA procedures for the PM2.5 program. The precision of an existing monitoring network was to be determined with collocated monitors and flow checks. The bias of a monitoring network was to be determined with a new QA procedure that required bi-monthly audits on all PM2.5 monitors using a portable FRM audit sampler. Consistent with Agency policy, this proposal was open to public comment and review. The Agency received over 30,000 comments many of which concerned the QA program. The QA system was modified, based upon these comments, to reduce the logistical burden for the implementation of the program. The subsequent modifications were finalized in the July 18, 1997 regulations published in the Federal Register. This finalized QA program required 25% of the monitors to be collocated, quarterly flow audits on all PM2.5 monitors used in the SLAMS network, and 25% of all PM2.5 monitors to be independently audited with the new FRM audit sampler. Details of the QA system are found in 40 CFR Part 58, Appendix A.

Musick, D.; Papp, M.; Elkins, J. [Environmental Protection Agency (United States)

1998-12-31T23:59:59.000Z

134

Quality Assurance Exchange June 2006, Volume 2 Issue 2 | Department...  

Broader source: Energy.gov (indexed) [DOE]

2 More Documents & Publications DOE G 414.1-4, Safety Software Guide for Use with 10 CFR 830 Subpart A, Quality Assurance Requirements, and DOE O 414.1C, Quality Assurance...

135

CISC 327* Software Quality Assurance! Course Summary and Study Guide!  

E-Print Network [OSTI]

parameters. ! ! What is Quality Assurance? - software quality assurance, the three general principles of QA, design, implementation and testing, operation and ! ! ! maintenance, retirement. Drawbacks Oriented Development Model - phases: analysis, design, implementation. OO analysis - ! ! ! the essential

Cordy, James R.

136

Quality Assurance Exchange Setpebmer 2007, Volume 3 Issue 3  

Broader source: Energy.gov [DOE]

Quality Assurance Exchange Setpebmer 2007, Volume 3 Issue 3 U.S. Department of Energy Office of Corporate Safety Analysis

137

Quality Assurance Exchange August 2007, Volume 3 Issue 2  

Broader source: Energy.gov [DOE]

Quality Assurance Exchange August 2007, Volume 3 Issue 2 U.S. Department of Energy Office of Corporate Safety Analysis

138

Quality Assurance Exchange January 2007, Volume 3 Issue 1  

Broader source: Energy.gov [DOE]

Quality Assurance Exchange January 2007, Volume 3 Issue 1 U.S. Department of Energy Office of Corporate Safety Analysis

139

Model-based Quality Assurance of Automotive Software  

E-Print Network [OSTI]

Model-based Quality Assurance of Automotive Software Jan Jürjens1 , Daniel Reiss2 , David (Germany) #12;Jan Jürjens et al.: Model-based Quality Assurance of Automotive Software 2 The Problem (Meta. #12;Jan Jürjens et al.: Model-based Quality Assurance of Automotive Software 3 The Problem (Meta

Jurjens, Jan

140

UMTRA project technical assistance contractor quality assurance implementation plan  

SciTech Connect (OSTI)

The Uranium Mill Tailings Remedial Action (UMTRA) Project Technical Assistance contractor (TAC) Quality Assurance Implementation Plan (QAIP) outlines the primary requirements for integrating quality functions for TAC technical activities applied to the surface and ground water phases of the UMTRA Project. The QAIP is subordinate to the latest issue of the UMTRA Project TAC Quality Assurance Program Plan (QAPP) (DOE, 1993a), which was developed using US Department of Energy (DOE) Order 5700.6C quality assurance (QA) criteria. The QAIP addresses technical aspects of the TAC UMTRA Project surface and ground water programs. All QA issues in the QAIP shall comply with requirements contained in the TAC QAPP (DOE, 1933a). Because industry standards for data acquisition and data control are not addressed in DOE Order 5700.6C, the QAIP has been formatted to the 14 US Environmental Protection Agency (EPA) Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) QA requirements. DOE Order 5700.6C criteria that are not contained in the CERCLA requirements are added to the QAIP as additional requirements in Sections 15.0 through 18.0. Project documents that contain CERCLA requirements and 5700.6 criteria shall be referenced in this document to avoid duplication. Referenced documents are not included in this QAIP but are available through the UMTRA Project Document Control Center.

Not Available

1994-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Conduct of Operations and Quality Assurance Compliance  

SciTech Connect (OSTI)

The purpose of this document is to present and detail the deliverables for the Tiger Team Action Plan, Finding MF-11, and milestones in the FY92 Performance Appraisal for Conduct of Operations from Sandia National Laboratories to DOE. The ``Proposal for Reporting Conduct of Operations & Quality Assurance Compliance to DOE`` describes what the deliverables shall be. Five major steps that result in the development of line practices are covered in this document. These line practices specify what Sandia will do to comply with the above DOE management orders. The five steps include: hazard classification; programmatic risk classification; management grouping; compliance plan; and corporate reporting.

Andrews, N.S.

1992-06-01T23:59:59.000Z

142

Conduct of Operations and Quality Assurance Compliance  

SciTech Connect (OSTI)

The purpose of this document is to present and detail the deliverables for the Tiger Team Action Plan, Finding MF-11, and milestones in the FY92 Performance Appraisal for Conduct of Operations from Sandia National Laboratories to DOE. The Proposal for Reporting Conduct of Operations Quality Assurance Compliance to DOE'' describes what the deliverables shall be. Five major steps that result in the development of line practices are covered in this document. These line practices specify what Sandia will do to comply with the above DOE management orders. The five steps include: hazard classification; programmatic risk classification; management grouping; compliance plan; and corporate reporting.

Andrews, N.S.

1992-06-01T23:59:59.000Z

143

WIPP Documents - Quality Assurance and Safety  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert SouthwestTechnologies | Blandine Jerome VelenciaNewsNewsFederalQuality Assurance

144

Underground Test Area Quality Assurance Project Plan Nevada National Security Site, Nevada, Revision 0  

SciTech Connect (OSTI)

This Quality Assurance Project Plan (QAPP) provides the overall quality assurance (QA) program requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) Sub-Project (hereafter the Sub-Project) activities. The requirements in this QAPP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). The QAPP Revision 0 supersedes DOE--341, Underground Test Area Quality Assurance Project Plan, Nevada Test Site, Nevada, Revision 4.

Irene Farnham

2011-05-01T23:59:59.000Z

145

Large hadron collider (LHC) project quality assurance plan  

SciTech Connect (OSTI)

The LHC Quality Assurance Plan is a set of operating principles, requirements, and practices used to support Berkeley Lab's participation in the Large Hadron Collider Project. The LHC/QAP is intended to achieve reliable, safe, and quality performance in the LHC project activities. The LHC/QAP is also designed to fulfill the following objectives: (1) The LHC/QAP is Berkeley Lab's QA program document that describes the elements necessary to integrate quality assurance, safety management, and conduct of operations into the Berkeley Lab's portion of the LHC operations. (2) The LHC/QAP provides the framework for Berkeley Lab LHC Project administrators, managers, supervisors, and staff to plan, manage, perform, and assess their Laboratory work. (3) The LHC/QAP is the compliance document that conforms to the requirements of the Laboratory's Work Smart Standards for quality assurance (DOE O 414.1, 10 CFR 830.120), facility operations (DOE O 5480.19), and safety management (DOE P 450.4).

Gullo, Lisa; Karpenko, Victor; Robinson, Kem; Turner, William; Wong, Otis

2002-09-30T23:59:59.000Z

146

Quality assurance in the transport of UF{sub 6}  

SciTech Connect (OSTI)

Edlow International`s primary business is the international transportation of radioactive materials. Therefore, Edlow has the responsibility to ensure that shipments are performed in compliance with regulatory requirements. In this regard, Edlow maintains a Quality Assurance (QA) Program. A major part of this Program is the establishment and use of QA Procedures. This paper addresses QA procedural requirements and how they are applied to a routine international shipment of low enriched UF{sub 6}. Only the major requirements for scheduling shipments will be addressed.

Ravenscroft, N.L. [Edlow International Company, Washington, DC (United States)

1991-12-31T23:59:59.000Z

147

Quality Assurance 9 2009 Site environmental report9-  

E-Print Network [OSTI]

throughout the entire organization. The purpose of the BNL Quality Management (QM) System is to implement QM methodology throughout the various Laboratory management systems and associated processes, in order to: PlanQuality Assurance 9 2009 Site environmental report9- DRAFT Quality assurance is an integral part

148

Quality Assurance 9 2008 Site environmental report9-  

E-Print Network [OSTI]

throughout the entire organization. The purpose of the BNL Quality Management (QM) System is to implement QM methodology throughout the various Laboratory management systems and associated processes, in order to: PlanQuality Assurance 9 2008 Site environmental report9- DRAFT Quality assurance is an integral part

149

Geothermal: Sponsored by OSTI -- Quality Assurance of NUFT Code...  

Office of Scientific and Technical Information (OSTI)

Quality Assurance of NUFT Code for Underground Test Area (UGTA) Activities Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us HomeBasic Search About...

150

SAPHIRE 8 Software Quality Assurance Plan  

SciTech Connect (OSTI)

This Quality Assurance (QA) Plan documents the QA activities that will be managed by the INL related to JCN N6423. The NRC developed the SAPHIRE computer code for performing probabilistic risk assessments (PRAs) using a personal computer (PC) at the Idaho National Laboratory (INL) under Job Code Number (JCN) L1429. SAPHIRE started out as a feasibility study for a PRA code to be run on a desktop personal PC and evolved through several phases into a state-of-the-art PRA code. The developmental activity of SAPHIRE was the result of two concurrent important events: The tremendous expansion of PC software and hardware capability of the 90s and the onset of a risk-informed regulation era.

Curtis Smith

2010-02-01T23:59:59.000Z

151

E-Print Network 3.0 - assurance programs developed Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

4 hours Software Product vs. Software process Quality Assurance vs. Quality Control Quality... quality assurance, quality measures, and ... Source: Saniie, Jafar - Department of...

152

The Quality Assurance Manual and EPA`s acid rain data quality  

SciTech Connect (OSTI)

November 15, 1990 saw the passage of the Clean Air Act Amendments of 1990. Within this law was the requirements for all electric utility units greater than 25 megawatts of generated electrical capacity to monitor SO{sub 2}, NO{sub x}, CO{sub 2}, opacity, and volumetric flow of the stack gases. This paper summarizes the Acid Rain Program`s approach to Continuous Emissions Monitoring Systems (CEMS) Quality Control and Quality Assurance requirements and their use in the market based pollution control program of Title IV of the Clean Air Act Amendments of 1990. This paper attempts to present the perspective of the authors as to what is important for excellent monitoring system availability and ensuring accurate data acquisition. Emphasis is placed upon the Quality Assurance Manual required by the Acid Rain Regulations for affected unit`s to maintain and follow.

Bloomer, B.J. [EPA, Washington, DC (United States). Acid Rain Div.; Winkler, J.P. [EPA, Dallas, TX (United States)

1995-12-31T23:59:59.000Z

153

Guidance for the Quality Assurance of Fire Protection Systems  

Broader source: Energy.gov [DOE]

This quality assurance document is intended to provide guidance for the DOE fire protection community in the continuing effort to ensure the reliability of fire protection systems. This guidance document applies the concepts of DOE Order 5700.6C, Quality Assurance, to the management of fire protection systems.

154

Up-Stream Dissolved Oxygen TMDL Project Quality Assurance ProjectPlan  

SciTech Connect (OSTI)

A quality assurance project plan (QAPP) for the execution of an ecosystem level monitoring and research program examining algal ecology in highly impaired rivers. Procedures for executing both field and laboratory surface water quality and flow analysis are described. The procedures described here are compatible with the California Surface Water Ambient Monitoring program (SWAMP).

Stringfellow, William T.

2005-05-13T23:59:59.000Z

155

OG&E's Power Quality Program  

E-Print Network [OSTI]

Our commitment to reliable electric power does not stop at the meter, but extends all the way to the equipment that it operates. Through the Power Quality Program, we provide professional power consultants to assure that the customer has quality...

Davis, M.

156

Handbook of software quality assurance techniques applicable to the nuclear industry  

SciTech Connect (OSTI)

Pacific Northwest Laboratory is conducting a research project to recommend good engineering practices in the application of 10 CFR 50, Appendix B requirements to assure quality in the development and use of computer software for the design and operation of nuclear power plants for NRC and industry. This handbook defines the content of a software quality assurance program by enumerating the techniques applicable. Definitions, descriptions, and references where further information may be obtained are provided for each topic.

Bryant, J.L.; Wilburn, N.P.

1987-08-01T23:59:59.000Z

157

Software Quality Assurance Plan for GoldSim Models Supporting the Area 3 and Area 5 Radioactive Waste Management Sites Performance Assessment Program  

SciTech Connect (OSTI)

This Software Quality Assurance Plan (SQAP) applies to the development and maintenance of GoldSim models supporting the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) performance assessments (PAs) and composite analyses (CAs). Two PA models have been approved by the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) as of November 2006 for the PA maintenance work undertaken by National Security Technologies, LLC (NSTec). NNSA/NSO asked NSTec to assume the custodianship of the models for future development and maintenance. The models were initially developed by Neptune and Company (N&C).

Gregory J. Shott, Vefa Yucel

2007-01-03T23:59:59.000Z

158

The Columbia River Protection Supplemental Technologies Quality Assurance Project Plan  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) has conducted interim groundwater remedial activities on the Hanford Site since the mid-1990s for several groundwater contamination plumes. DOE established the Columbia River Protection Supplemental Technologies Project (Technologies Project) in 2006 to evaluate alternative treatment technologies. The objectives for the technology project are as follows: develop a 300 Area polyphosphate treatability test to immobilize uranium, design and test infiltration of a phosphate/apatite technology for Sr-90 at 100-N, perform carbon tetrachloride and chloroform attenuation parameter studies, perform vadose zone chromium characterization and geochemistry studies, perform in situ biostimulation of chromium studies for a reducing barrier at 100-D, and perform a treatability test for phytoremediation for Sr-90 at 100-N. This document provides the quality assurance guidelines that will be followed by the Technologies Project. This Quality Assurance Project Plan is based on the quality assurance requirements of DOE Order 414.1C, Quality Assurance, and 10 CFR 830, Subpart A--Quality Assurance Requirements as delineated in Pacific Northwest National Laboratory’s Standards-Based Management System. In addition, the technology project is subject to the Environmental Protection Agency (EPA) Requirements for Quality Assurance Project Plans (EPA/240/B-01/003, QA/R-5). The Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD, DOE/RL-96-68) apply to portions of this project and to the subcontractors. HASQARD requirements are discussed within applicable sections of this plan.

Fix, N. J.

2007-01-10T23:59:59.000Z

159

Chemical analysis quality assurance at the Idaho Chemical Processing Plant  

SciTech Connect (OSTI)

The Idaho Chemical Processing Plant (ICPP) is a uranium reprocessing facility operated by Westinghouse Idaho Nuclear Company for the Department of Energy at the Idaho National Engineering Laboratory (INEL). The chemical analysis support required for the plant processes is provided by a chemical analysis staff of 67 chemists, analysts, and support personnel. The documentation and defense of the chemical analysis data at the ICPP has evolved into a complete chemical analysis quality assurance program with training/qualification and requalification, chemical analysis procedures, records management and chemical analysis methods quality control as major elements. The quality assurance procedures are implemented on a central analytical computer system. The individual features provided by the computer system are automatic method selection for process streams, automation of method calculations, automatic assignment of bias and precision estimates at analysis levels to all method results, analyst specific daily requalification or with-method-use requalification, untrained or unqualified analyst method lockout, statistical testing of process stream results for replicate agreement, automatic testing of process results against pre-established operating, safety, or failure limits at varying confidence levels, and automatic transfer and report of analysis data plus the results of all statistical testing to the Production Department.

Hand, R.L.; Anselmo, R.W.; Black, D.B.; Jacobson, J.J.; Lewis, L.C.; Marushia, P.C.; Spraktes, F.W.; Zack, N.R.

1985-01-01T23:59:59.000Z

160

QAS 2.6 Quality Assurance Records 3/15/95 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

6 Quality Assurance Records 31595 QAS 2.6 Quality Assurance Records 31595 The objective of this surveillance is to evaluate the effectiveness of the contractor's implementation...

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Product Quality Assurance for Off-Grid Lighting in Africa  

SciTech Connect (OSTI)

Although the emergence of markets for high efficiency off-grid lighting technologies holds promise, realizing the potential of this opportunity on a long-term, sustainable basis requires careful attention to issues of product quality, consumer protection, and the potential for significant 'market spoiling', in anticipation of increases of sales of low cost, low performance off-grid lighting products. The goal of the Lighting Africa quality assurance workshop was to articulate strategies to mitigate the dangers of market spoiling and to explore ways to protect consumers from misleading advertising for sales of inferior, off-grid lighting products in the context of Lighting Africa's overarching objective to support the industry in developing a robust off-grid lighting market in Africa. The workshop resulted in the identification of two strategic approaches for meeting Lighting Africa quality assurance programmatic needs. The first strategy is intended to meet a short-term programmatic need for quality associated with requests for lighting products by bulk procurement agents, such as in a World Bank-financed project. The development of procurement specifications and test procedures that could be used in a quality/usability screening method in order to provide guidance for forthcoming large volume purchases emerged as the best solution to meet this need. Such approaches are used in World Bank-financed solar home systems (SHSs) projects in Bangladesh, Sri Lanka, and China, among others. However, unlike the SHSs which have multiple balance-of-system (BOS) components warranting the need for an array of specifications for individual components, stand alone lighting systems require specifications that are amenable to individual light points. To test this approach, Lighting Africa elected to use the technical specifications issued by the Photovoltaic Global Approval Program for solar lanterns that use CFL bulbs (PVRS11A) as the basis of qualifying such products. A contract has been competitively awarded to the Global Approval Program for Photovoltaics (PV GAP) under the Lighting Africa Program to select and test ten solar lantern product models. Lantern selection will be determined based on a number of criteria, among them, the ability to provide a daily duty cycle of at least 3 hours of light, the number of days of autonomy of battery, the volume of sales (especially in Africa), and whether or not the manufacturing facility is ISO 9000 certified. Those that are confirmed as meeting the specifications may be eligible to receive a PVGAP quality seal. The work is being carried out in partnership with the Photovoltaic and Wind Quality Test Center in Beijing, China and TUV Rhineland in Koeln, Germany. As off-grid LED-based stand-alone lighting products is in a nascent stage of development compared to CFL-based lanterns, Lighting Africa will support the development of a 'Quality Screening' approach to selecting LED lighting, in order not to delay consumers benefiting from such advances. The screening methodology could be used by procurement agencies to qualify LED lighting products for bulk or programmatic procurements. The main elements of this work comprises of developing a procurement specification and test procedure for undertaking a 'quick' quality/usability screening to be used for procuring LED lights and to test up to 30 LED-based lights to screen products that meet the requirement. The second strategy is intended to meet a longer-term need associated with creating a self-sustaining product quality assurance program that will effectively protect the African consumer, prevent significant market spoiling, adapt with expected technological advancements over the long-term--in other words, give consumers the ability to detect quality products and the information needed to find products that meet their specific needs from among the myriad of lighting products that become available commercially. Workshop discussions and the discussions evolving from the workshop led the Lighting Africa team to opt for an approach similar to that of th

World Bank; Mills, Evan; Mills, Evan

2008-07-13T23:59:59.000Z

162

Quality Assurance Protocol for AFCI Advanced Structural Materials Testing  

SciTech Connect (OSTI)

The objective of this letter is to inform you of recent progress on the development of advanced structural materials in support of advanced fast reactors and AFCI. As you know, the alloy development effort has been initiated in recent months with the procurement of adequate quantities of the NF616 and HT-UPS alloys. As the test alloys become available in the coming days, mechanical testing, evaluation of optimizing treatments, and screening of environmental effects will be possible at a larger scale. It is therefore important to establish proper quality assurance protocols for this testing effort in a timely manner to ensure high technical quality throughout testing. A properly implemented quality assurance effort will also enable preliminary data taken in this effort to be qualified as NQA-1 during any subsequent licensing discussions for an advanced design or actual prototype. The objective of this report is to describe the quality assurance protocols that will be used for this effort. An essential first step in evaluating quality protocols is assessing the end use of the data. Currently, the advanced structural materials effort is part of a long-range, basic research and development effort and not, as yet, involved in licensing discussions for a specific reactor design. After consultation with Mark Vance (an ORNL QA expert) and based on the recently-issued AFCI QA requirements, the application of NQA-1 quality requirements will follow the guidance provided in Part IV, Subpart 4.2 of the NQA-1 standard (Guidance on Graded Application of QA for Nuclear-Related Research and Development). This guidance mandates the application of sound scientific methodology and a robust peer review process in all phases, allowing for the data to be qualified for use even if the programmatic mission changes to include licensing discussions of a specific design or prototype. ORNL has previously implemented a QA program dedicated to GNEP activities and based on an appropriately graded application of NQA-1 requirements at the site. The current program is being revised to incorporate changes imposed through the recently revised AFCI Technical Integration Office QA requirements. Testing conducted under the AFCI QA program for the advanced structural materials effort shall incorporate the following quality assurance expectations: (1) personnel are adequately trained to perform assigned work; (2) activities are controlled to ensure consistency of results; (3) records necessary to substantiate how the work was performed are maintained (dedicated laboratory notebooks will be used); (4) the pedigree and traceability of the various tested materials are maintained throughout the described processes using consistent sample numbering and adequate record keeping; (5) equipment with the potential to affect the quality of the planned work is calibrated and maintained in accordance with applicable operating requirements. In addition, all reporting or related dissemination by ORNL personnel of the results of the work described in this subcontract shall be conducted in accordance with the requirements described or referenced in the ORNL Standards Based Management System subject area entitled Scientific and Technical Information. Reporting or publications at other institutions will be conducted in accordance with the requirements of that institution. Successful implementation of these protocols will provide a sound basis for future decisions and research. In addition, these steps will also help ensure that results can also be applied to licensing discussions at a future date.

Busby, Jeremy T [ORNL

2009-05-01T23:59:59.000Z

163

Master Pump Shutdown MPS Software Quality Assurance Plan (SQAP)  

SciTech Connect (OSTI)

The MPSS Software Quality Assurance (SQAP) describes the tools and strategy used in the development of the MPSS software. The document also describes the methodology for controlling and managing changes to the software.

BEVINS, R.R.

2000-09-20T23:59:59.000Z

164

Page 1 of 16 Quality Assurance Code of Practice  

E-Print Network [OSTI]

QA53 Page 1 of 16 Quality Assurance Code of Practice Examination and Assessment Offences 1. Purpose: · University Ordinances and Regulations; · QA28 Conduct of Examinations; · University Rule 2 : Conduct

Burton, Geoffrey R.

165

9-1 2002 SITE ENVIRONMENTAL REPORT CHAPTER 9: QUALITY ASSURANCE  

E-Print Network [OSTI]

. The purpose of the BNL Quality Management (QM) System is to implement QM methodology throughout the various9-1 2002 SITE ENVIRONMENTAL REPORT CHAPTER 9: QUALITY ASSURANCE Quality Assurance 9Quality assurance is an integral part of every activity at Brookhaven National Laboratory. BNLs Quality Assurance

Homes, Christopher C.

166

The Columbia River Protection Supplemental Technologies Quality Assurance Project Plan  

SciTech Connect (OSTI)

Pacific Northwest National Laboratory researchers are working on the Columbia River Protection Supplemental Technologies Project. This project is a U. S. Department of Energy, Office of Environmental Management-funded initiative designed to develop new methods, strategies, and technologies for characterizing, modeling, remediating, and monitoring soils and groundwater contaminated with metals, radionuclides, and chlorinated organics. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by the Technologies Project staff.

Fix, N. J.

2008-03-12T23:59:59.000Z

167

A pioneering application of NQA-1 quality assurance standards in the development of software  

SciTech Connect (OSTI)

One reason for systematically applying quality assurance to computer software is the extensive use of results from computer programs to characterize potential sited for nuclear waste repositories leading ultimately to important policy making decisions. Because data from these programs characterize the likely radioactivity profile for many hundreds of years, experimental validation is not feasible. The Sensitivity and Uncertainty Analysis Methods Development Project (SUAMDP) was developed to formulate and utilize efficient and comprehensive methods for determining sensitivities of calculated results with respect to changes in all input parameters. The computerized methodology was embodied in the Gradient Enhanced Software System (GRESS). Due to the fact that GRESS was to be used in the site characterization for waste storage, stringent NQA-1 requirements were imposed by the sponsor. A working relationship between the Oak Ridge National Laboratory (ORNL) Quality Department and the research scientists developing GRESS was essential in achieving understanding and acceptance of the quality assurance requirements as applied to the SUAMDP. The relationship resulted in the SUAMDP becoming the first software project at ORNL to develop a comprehensive NQA-1 Quality Assurance Plan; this plan now serves as a model for software quality assurance at ORNL. This paper describes the evolution of this plan and its impact on the application of quality assurance procedures to software. 2 refs.

Weisbin, A.N.

1988-01-01T23:59:59.000Z

168

Safety Software Guide for Use with 10 CFR 830, Subpart A, Quality Assurance Requirements, and DOE O 414.1C, Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Guide provides acceptable methods for implementing the safety software quality assurance requirements of draft DOE O 414.1C, Quality Assurance. Certified 11-3-10. No cancellation.

2005-06-17T23:59:59.000Z

169

Los Alamos National Laboratory transuranic waste quality assurance project plan. Revision 1  

SciTech Connect (OSTI)

This Transuranic (TRU) Waste Quality Assurance Project Plan (QAPjP) serves as the quality management plan for the characterization of transuranic waste in preparation for certification and transportation. The Transuranic Waste Characterization/Certification Program (TWCP) consists of personnel who sample and analyze waste, validate and report data; and provide project management, quality assurance, audit and assessment, and records management support, all in accordance with established requirements for disposal of TRU waste at the Waste Isolation Pilot Plant (WIPP) facility. This QAPjP addresses how the TWCP meets the quality requirements of the Carlsbad Area Office (CAO) Quality Assurance Program Description (QAPD) and the technical requirements of the Transuranic Waste Characterization Quality Assurance Program Plan (QAPP). The TWCP characterizes and certifies retrievably stored and newly generated TRU waste using the waste selection, testing, sampling, and analytical techniques and data quality objectives (DQOs) described in the QAPP, the Los Alamos National Laboratory Transuranic Waste Certification Plan (Certification Plan), and the CST Waste Management Facilities Waste Acceptance Criteria and Certification [Los Alamos National Laboratory (LANL) Waste Acceptance Criteria (WAC)]. At the present, the TWCP does not address remote-handled (RH) waste.

NONE

1997-04-14T23:59:59.000Z

170

Quality assurance for radioactive waste packages -- A general approach  

SciTech Connect (OSTI)

Radioactive waste packages must fulfill the requirements resulting from regulations concerning handling, treatment, conditioning, transportation, storage and disposal so that the goal of radioactive waste management can be achieved. Usually in different parts of waste management different quality systems are used, and different quality assurance measures are performed. In the paper, these problems ar elucidated and it is explained by means of the quality assurance performed for the disposal of radioactive waste in Germany how the fulfillment of the requirements of the repository can be ensured.

Martens, B.R. [Bundesamt fuer Strahlenschutz, Saltzgitter (Germany)

1993-12-31T23:59:59.000Z

171

Project Specific Quality Assurance Plan Project (QAPP) W-211 Initial Tank Retrieval Systems (ITRS)  

SciTech Connect (OSTI)

This Quality Assurance Program Plan (QAPP) provides information on how the Project Hanford Quality Assurance Program is implemented by CH2M HILL Hanford Group Inc (CHG) for managing the Initial Tank Retrieval Systems (ITRS), Project W-211. This QAPP is responsive to the CHG Quality Assurance Program Description (QAPD) (LMH-MP-599) which provides direction for compliance to 10 CFR 830 120, ''Nuclear Safety Management, Quality Assurance Requirements'', and DOE Order 5700 6C, ''Quality Assurance'' Project W-211 modifies existing facilities and provides systems for retrieval of radioactive wastes from selected double-shell tanks (DST). The contents of these tanks are a combination of supernatant liquids and settled solids. To retrieve waste from the tanks, it is first necessary to mix the liquid and solids prior to transferring the slurry to alternative storage or treatment facilities. The ITRS will provide systems to mobilize the settled solids and transfer the wastes out of the tanks. In so doing, ITRS provides feed for future processing plants, allows for consolidation of tank solids to manage space within existing DST storage capacity, and supports continued safe storage of tank waste. This project includes the design, procurement, construction, startup and turnover of these retrieval systems This QAPP identifies organizational structures and responsibilities. Implementing procedures used by CHG project management can be found in the CHG Quality Assurance Program (CHG QAP) Implementation Matrix located in HNF-IP-0842, Volume XI, Attachment Proposed verification and inspection activities for critical items within the scope of project W-211 are identified in Attachment 1 W-211. Project participants will identify the implementing procedures used by their organization within their QAF'Ps. This project specific QAPP is used to identify requirements in addition to the QAPD and provide, by reference, additional information to other project documents.

HALL, L.R.

2000-02-01T23:59:59.000Z

172

302:20130613.1452 Quality Assurance Group  

E-Print Network [OSTI]

the ISO 9001:2008 standard for quality systems. All elements of the ISO model are incorporated for critical spaceflight or commercial purposes, we design and implement quality plans adapted appropriately

Mojzsis, Stephen J.

173

IT Quality Assurance | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles »Exchange Visitors HistoryHybrid Wind and SolarITQuality Assurance

174

Quality assurance management plan (QAPP) special analytical support (SAS)  

SciTech Connect (OSTI)

It is the policy of Special Analytical Support (SAS) that the analytical aspects of all environmental data generated and processed in the laboratory, subject to the Environmental Protection Agency (EPA), U.S. Department of Energy or other project specific requirements, be of known and acceptable quality. It is the intention of this QAPP to establish and assure that an effective quality controlled management system is maintained in order to meet the quality requirements of the intended use(s) of the data.

LOCKREM, L.L.

1999-05-20T23:59:59.000Z

175

9-1 SITE ENVIRONMENTAL REPORT 2000 CHAPTER 9: QUALITY ASSURANCE  

E-Print Network [OSTI]

monitoring data are consistent with the requirements of 10 CFR 830 Subpart A, "Quality Assurance Requirements" and DOE Order 414.1 (1998), Quality Assurance. Responsibility for quality at BNL starts

Homes, Christopher C.

176

Isotopic power supplies for space and terrestrial systems: quality assurance by Sandia National Laboratories  

SciTech Connect (OSTI)

The Sandia National Laboratories participation in Quality Assurance (QA) programs for Radioisotopic Thermoelectric Generators which have been used in space and terrestrial systems over the past 15 years is summarized. Basic elements of the program are briefly described and recognition of assistance from other Sandia organizations is included. Descriptions of the various systems for which Sandia has had the QA responsibility are also presented. In addition, the outlook for Sandia participation in RTG programs for the next several years is noted.

Hannigan, R.L.; Harnar, R.R.

1981-09-01T23:59:59.000Z

177

9-1 2001 SITE ENVIRONMENTAL REPORT CHAPTER 9: QUALITY ASSURANCE  

E-Print Network [OSTI]

Environmental Laboratory Approval Program (potable and nonpotable water), BNL received a satisfactory rating and expectations. For environmental monitoring, QA is defined as an integrated system of management activities9-1 2001 SITE ENVIRONMENTAL REPORT CHAPTER 9: QUALITY ASSURANCE 2001 SITE ENVIRONMENTAL REPORT

Homes, Christopher C.

178

CRAD, Quality Assurance- Los Alamos National Laboratory Waste Characterization, Reduction, and Repackaging Facility  

Broader source: Energy.gov [DOE]

A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for an assessment of the Quality Assurance Program portion of an Operational Readiness Review at the Los Alamos National Laboratory Waste Characterization, Reduction, and Repackaging Facility.

179

CRAD, Quality Assurance- Oak Ridge National Laboratory TRU ALPHA LLWT Project  

Broader source: Energy.gov [DOE]

A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for a November 2003 assessment of the Quality Assurance Program portion of an Operational Readiness Review of the Oak Ridge National Laboratory TRU ALPHA LLWT Project.

180

CRAD, Quality Assurance- Oak Ridge National Laboratory High Flux Isotope Reactor  

Broader source: Energy.gov [DOE]

A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for a February 2007 assessment of the Quality Assurance Program in preparation for restart of the Oak Ridge National Laboratory High Flux Isotope Reactor.

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

CRAD, Quality Assurance- Los Alamos National Laboratory TA 55 SST Facility  

Broader source: Energy.gov [DOE]

A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for an assessment of the Quality Assurance Program at the Los Alamos National Laboratory TA 55 SST Facility.

182

Model-Based Quality Assurance of Automotive Software  

E-Print Network [OSTI]

Model-Based Quality Assurance of Automotive Software Jan Jürjens1 , Daniel Rei�2 , and David, Germany Abstract. Software in embedded (e.g. automotive) systems requires a high level of reliability to the automotive sector, characterized by strict safety requirements to com- ponents of a motor vehicle (see [5, 16

Jurjens, Jan

183

SCIENTIFIC NOTE Variations in daily quality assurance dosimetry from device  

E-Print Network [OSTI]

SCIENTIFIC NOTE Variations in daily quality assurance dosimetry from device levelling, feet procedures are an essential part of radiotherapy medical physics. Devices such as the Sun Nuclear, DQA3 are effective tools for analysis of daily dosimetry including flatness, symmetry, energy, field size and central

Yu, K.N.

184

Revenue Maximization with Quality Assurance for Composite Web Services  

E-Print Network [OSTI]

Revenue Maximization with Quality Assurance for Composite Web Services Dani¨el Worm, Miroslav Abstract--Service composition is one of the major approaches in service oriented architecture (SOA) based systems. Due to the inherent stochastic nature of services execution environment the issue of composite

van der Mei, Rob

185

Quality Assurance Procedures for ModCat Database Code Files  

SciTech Connect (OSTI)

The Quality Assurance procedures used for the initial phase of the Model Catalog Project were developed to attain two objectives, referred to as “basic functionality” and “visualization.” To ensure the Monte Carlo N-Particle model input files posted into the ModCat database meet those goals, all models considered as candidates for the database are tested, revised, and re-tested.

Siciliano, Edward R.; Devanathan, Ram; Guillen, Zoe C.; Kouzes, Richard T.; Schweppe, John E.

2014-04-01T23:59:59.000Z

186

UMTRA project technical assistance contractor quality assurance implementation plan for surface and ground water  

SciTech Connect (OSTI)

The Uranium Mill Tailings Remedial Action (UMTRA) Project Technical Assistance Contractor (TAC) Quality Assurance Implementation Plan (QAIP) outlines the primary requirements for integrating quality functions for TAC technical activities applied to the surface and ground water phases of the UMTRA Project. The QAIP is subordinate to the latest issue of the UMTRA Project TAC Quality Assurance Program Plan (QAPP). The QAIP addresses technical aspects of the TAC UMTRA Project surface and ground water programs. The QAIP is authorized and approved by the TAC Project Manager and QA manager. The QA program is designed to use monitoring, audit, and surveillance functions as management tools to ensure that all Project organization activities are carried out in a manner that will protect public health and safety, promote the success of the UMTRA Project and meet or exceed contract requirements.

Not Available

1994-09-01T23:59:59.000Z

187

SAPHIRE 8 Quality Assurance Software Metrics Report  

SciTech Connect (OSTI)

The purpose of this review of software metrics is to examine the quality of the metrics gathered in the 2010 IV&V and to set an outline for results of updated metrics runs to be performed. We find from the review that the maintenance of accepted quality standards presented in the SAPHIRE 8 initial Independent Verification and Validation (IV&V) of April, 2010 is most easily achieved by continuing to utilize the tools used in that effort while adding a metric of bug tracking and resolution. Recommendations from the final IV&V were to continue periodic measurable metrics such as McCabe's complexity measure to ensure quality is maintained. The four software tools used to measure quality in the IV&V were CodeHealer, Coverage Validator, Memory Validator, Performance Validator, and Thread Validator. These are evaluated based on their capabilities. We attempted to run their latest revisions with the newer Delphi 2010 based SAPHIRE 8 code that has been developed and was successful with all of the Validator series of tools on small tests. Another recommendation from the IV&V was to incorporate a bug tracking and resolution metric. To improve our capability of producing this metric, we integrated our current web reporting system with the SpiraTest test management software purchased earlier this year to track requirements traceability.

Kurt G. Vedros

2011-08-01T23:59:59.000Z

188

E-Print Network 3.0 - assurance program plan Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

, and early adoption. SOURCES Although we knew of no existing graduate degree programs in software assurance... for graduates of a software assurance program ... Source:...

189

Subject: Quality Assurance Letter To Whom It May Concern  

E-Print Network [OSTI]

program, appropriate facilities and equipment qualification to support quality services, as well and test qualification to ensure the quality of routine services. As part of our Quality System Management

Thomas, David D.

190

Software Quality Assurance Control of Existing Systems  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' Research |RegulationRenewable Energy (EERE)SmartRemarks Prepared for EnergyQuality

191

Introduction of Break-Out Session at the International PV Module Quality Assurance Forum (Presentation)  

SciTech Connect (OSTI)

This presentation outlines review requirements for quality assurance (QA) rating systems, logical design of QA systems, and specific tasks for break-out session 1 of the 2011 International PV Module Quality Assurance Forum.

Kurtz, S.; Wohlgemuth, J.; Yamamichi, M.; Sample, T.

2011-07-01T23:59:59.000Z

192

Security and Emergency Management Independent Oversight and Performance Assurance Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

Establishes the DOE Security and Emergency Management Independent Oversight and Performance Assurance Program. Cancels DOE O 470.2, Paragraph 5b(2) of DOE O 231.1 and Chapter IV of DOE M 231.1-1.

2000-03-01T23:59:59.000Z

193

Building commissioning: The key to quality assurance  

SciTech Connect (OSTI)

This Guide is written to aid building owners and retrofit project managers currently participating in the Rebuild America program. The Guide provides information on implementing building commissioning projects that will optimize the results of existing building equipment improvements and retrofits projects. It should be used in coordination with Rebuild America`s Community Partnership Handbook. The Handbook describes, in detail, eight important steps necessary for planning and carrying out a community-wide energy-efficiency program. In step number 7 of the Handbook, commissioning is shown to be an integral aspect of implementing a building retrofit. The commissioning process ensures that a facility is safe, efficient, comfortable, and conducive to the presumed activities for which it was constructed. Rebuild America strongly encourages its partners to incorporate commissioning into their retrofit projects. By verifying the correct installation, functioning, operation, and maintenance of equipment, the commissioning process ensures that efficiency measures will continue to deliver benefits over the long term. Although commissioning can take place after the equipment has been installed, it is more effective when it takes place over the entire equipment installation process.

NONE

1998-05-01T23:59:59.000Z

194

EECLP Webinar #2: Quality Assurance and Evaluation Monitoring Verification-- Text Version  

Broader source: Energy.gov [DOE]

Below is the text version of the EECLP Webinar #2: Quality Assurance and Evaluation Monitoring Verification, presented in December 2014.

195

The CHPRC Columbia River Protection Project Quality Assurance Project Plan  

SciTech Connect (OSTI)

Pacific Northwest National Laboratory researchers are working on the CHPRC Columbia River Protection Project (hereafter referred to as the Columbia River Project). This is a follow-on project, funded by CH2M Hill Plateau Remediation Company, LLC (CHPRC), to the Fluor Hanford, Inc. Columbia River Protection Project. The work scope consists of a number of CHPRC funded, related projects that are managed under a master project (project number 55109). All contract releases associated with the Fluor Hanford Columbia River Project (Fluor Hanford, Inc. Contract 27647) and the CHPRC Columbia River Project (Contract 36402) will be collected under this master project. Each project within the master project is authorized by a CHPRC contract release that contains the project-specific statement of work. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by the Columbia River Project staff.

Fix, N. J.

2008-11-30T23:59:59.000Z

196

2010 Quality Assurance Improvement Project Plan | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement Awardflash2007-42attachment1.pdfmodule 4Department0 Quality Assurance Improvement

197

2012 Quality Assurance Improvement Project Plan | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement Awardflash2007-42attachment1.pdfmodule(EE)2012 Nuclear Energy2012 Quality Assurance

198

Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities  

SciTech Connect (OSTI)

This Quality Assurance Project Plan addresses the quality assurance requirements for the Facility Monitoring Plans of the overall site-wide environmental monitoring plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of individual Facility Effluent Monitoring Plans. This document is intended to be a basic road map to the Facility Effluent Monitoring Plan documents (i.e., the guidance document for preparing Facility Effluent Monitoring Plans, Facility Effluent Monitoring Plan determinations, management plan, and Facility Effluent Monitoring Plans). The implementing procedures, plans, and instructions are appropriate for the control of effluent monitoring plans requiring compliance with US Department of Energy, US Environmental Protection Agency, state, and local requirements. This Quality Assurance Project Plan contains a matrix of organizational responsibilities, procedural resources from facility or site manuals used in the Facility Effluent Monitoring Plans, and a list of the analytes of interest and analytical methods for each facility preparing a Facility Effluent Monitoring Plan. 44 refs., 1 figs., 2 tabs.

Nickels, J.M.

1991-06-01T23:59:59.000Z

199

9 QUALITY ASSURANCE AND QUALITY CONTROL 9.1 Introduction  

E-Print Network [OSTI]

for their intended use. A quality system is a management system that describes the elements necessary to plan in the use of radioactive materials. There are self-imposed internal quality management systems (e.g., DOE an organization-specific quality system, there is no need to develop new quality management systems, to the extent

200

Quality Assurance for Critical Decision Reviews RM | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems Engineering Research and DevelopmentDepartmentin DesignQuality Assurance for

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Quality Assurance Exchange March 2011, Volume 7 Issue 1  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalancedDepartment ofColumbus HTS1, 2008 CompanyQTRQuality AssuranceQuality

202

Quality Assurance Project Plan for radioactive airborne emissions data compilation and reporting  

SciTech Connect (OSTI)

This Quality Assurance Project Plan addresses the quality assurance requirements for compiling data from radioactie aiborne emissions. These data will be reported to the US Environmental Protection Agency, the US Department of Energy, and the Washington State Department of Health. Hanford Site radioactive airborne emissions are reported to the US Environmental Protection Agency in compliance with Title 40, Protection of the Environment, Code of Federal Regulations, Part 61, ``National Emissions Standards for Hazardous Air Pollutants , ``Subpart H, ``National Emissions Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities`` (EPA 1989a). Reporting to US Department of Energy is performed in compliance with requirements of US Department of Energy Order 5400.1, General Environmental Protection Program (DOE 1988a).

Burris, S.A.; Thomas, S.P.

1994-02-01T23:59:59.000Z

203

UMTRA project technical assistance contractor quality assurance implementation plan for surface and ground water, Revision 2  

SciTech Connect (OSTI)

This document contains the Technical Assistance Contractor (TAC) Quality Assurance Implementation Plan (QAIP) for the Uranium Mill Tailings Remedial Action (UMTRA) Project. The QAIP outlines the primary requirements for integrating quality functions for TAC technical activities applied to the surface and ground water phases of the UMTRA Project. The QA program is designed to use monitoring, audit, and surveillance activities as management tools to ensure that UMTRA Project activities are carried out in amanner to protect public health and safety, promote the success of the UMTRA Project, and meet or exceed contract requirements.

NONE

1995-11-01T23:59:59.000Z

204

Quality Assurance Baseline Assessment Report to Los Alamos National Laboratory Analytical Chemistry Operations  

SciTech Connect (OSTI)

This report summarizes observations that were made during a Quality Assurance (QA) Baseline Assessment of the Nuclear Materials Technology Analytical Chemistry Group (NMT-1). The Quality and Planning personnel, for NMT-1, are spending a significant amount of time transitioning out of their roles of environmental oversight into production oversight. A team from the Idaho National Engineering and Environmental Laboratory Defense Program Environmental Surety Program performed an assessment of the current status of the QA Program. Several Los Alamos National Laboratory Analytical Chemistry procedures were reviewed, as well as Transuranic Waste Characterization Program (TWCP) QA documents. Checklists were developed and the assessment was performed according to an Implementation Work Plan, INEEL/EXT-98-00740.

Jordan, R. A.

1998-09-01T23:59:59.000Z

205

E-Print Network 3.0 - analytical quality assurance Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

for NRDA followed standard operating procedure (SOP), water sampling plans, Summary: procedures, and NOAA's Analytical Quality Assurance Project Plan (QAPP). Samples were sent...

206

Software quality assurance in the 1996 performance assessment for the Waste Isolation Pilot Plant  

SciTech Connect (OSTI)

The US Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP), located in southeast New Mexico, is a deep geologic repository for the permanent disposal of transuranic waste generated by DOE defense-related activities. Sandia National Laboratories (SNL), in its role as scientific advisor to the DOE, is responsible for evaluating the long-term performance of the WIPP. This risk-based Performance Assessment (PA) is accomplished in part through the use of numerous scientific modeling codes, which rely for some of their inputs on data gathered during characterization of the site. The PA is subject to formal requirements set forth in federal regulations. In particular, the components of the calculation fall under the configuration management and software quality assurance aegis of the American Society of Mechanical Engineers(ASME) Nuclear Quality Assurance (NQA) requirements. This paper describes SNL's implementation of the NQA requirements regarding software quality assurance (SQA). The description of the implementation of SQA for a PA calculation addresses not only the interpretation of the NQA requirements, it also discusses roles, deliverables, and the resources necessary for effective implementation. Finally, examples are given which illustrate the effectiveness of SNL's SQA program, followed by a detailed discussion of lessons learned.

FROEHLICH,GARY K.; OGDEN,HARVEY C.; BYLE,KATHLEEN A.

2000-05-23T23:59:59.000Z

207

Independent Oversight and Performance Assurance Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Independent Oversight Program is designed to enhance the DOE safeguards and security; cyber security; emergency management; and environment, safety, and health programs by providing DOE and contractor managers, Congress, and other stakeholders with an independent evaluation of the adequacy of DOE policy and the effectiveness of line management performance in safeguards and security; cyber security; emergency management; environment, safety, and health; and other critical functions as directed by the Secretary. Cancels DOE O 470.2A and Attachment 2 of DOE O 414.1A. Canceled by DOE O 227.1.

2002-10-31T23:59:59.000Z

208

Quality-Assurance and Data Management Plan for Groundwater Activities by the U.S. Geological  

E-Print Network [OSTI]

.....................................................................................................................................................1 Transition to Electronic Data ManagementQuality-Assurance and Data Management Plan for Groundwater Activities by the U.S. Geological Survey;#12;Quality-Assurance and Data Management Plan for Groundwater Activities by the U.S. Geological Survey

209

Quality Assurance Program | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' Research | DepartmentDepartmentHatch, Maryanne5 Updatescomments August 8,The

210

Quality Assurance 9 2010 SITE ENVIRONMENTAL REPORT9-1  

E-Print Network [OSTI]

Management (QM) System is to implement QM methodology throughout the various Laboratory management systems is de- ployed as an integrated system of management activities. These activities involve planning- ect manager for each environmental program determines the type, amount, and quality of data needed

211

Quality Assurance 9 2011 Site environmental report9-1  

E-Print Network [OSTI]

Management (QM) System is to implement QM methodology throughout the various Laboratory management systems is de- ployed as an integrated system of management activities. These activities involve planning- ect manager for each environmental program determines the type, amount, and quality of data needed

212

Quality Assurance 9 2012 SITE ENVIRONMENTAL REPORT9-1  

E-Print Network [OSTI]

Management (QM) System is to implement QM methodology throughout the various Laboratory management systems is de- ployed as an integrated system of management activities. These activities involve planning- ect manager for each environmental program determines the type, amount, and quality of data needed

213

Skoll: A Process and Infrastructure for Distributed Continuous Quality Assurance  

E-Print Network [OSTI]

configurations built from rapidly changing component implementations. Since today's quality as- surance (QA, on developer platforms, using developer-generated input workloads. One benefit of in-house QA is that programs software QA processes and tools that leverage the extensive computing resources of user and developer

Porter, Adam

214

Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179  

SciTech Connect (OSTI)

Purpose: Commercial CT-based image-guided radiotherapy (IGRT) systems allow widespread management of geometric variations in patient setup and internal organ motion. This document provides consensus recommendations for quality assurance protocols that ensure patient safety and patient treatment fidelity for such systems. Methods: The AAPM TG-179 reviews clinical implementation and quality assurance aspects for commercially available CT-based IGRT, each with their unique capabilities and underlying physics. The systems described are kilovolt and megavolt cone-beam CT, fan-beam MVCT, and CT-on-rails. A summary of the literature describing current clinical usage is also provided. Results: This report proposes a generic quality assurance program for CT-based IGRT systems in an effort to provide a vendor-independent program for clinical users. Published data from long-term, repeated quality control tests form the basis of the proposed test frequencies and tolerances.Conclusion: A program for quality control of CT-based image-guidance systems has been produced, with focus on geometry, image quality, image dose, system operation, and safety. Agreement and clarification with respect to reports from the AAPM TG-101, TG-104, TG-142, and TG-148 has been addressed.

Bissonnette, Jean-Pierre; Balter, Peter A.; Dong Lei; Langen, Katja M.; Lovelock, D. Michael; Miften, Moyed; Moseley, Douglas J.; Pouliot, Jean; Sonke, Jan-Jakob; Yoo, Sua [Task Group 179, Department of Radiation Physics, Princess Margaret Hospital, University of Toronto, Toronto, Ontario, M5G 2M9 (Canada); Department of Radiation Physics, University of Texas M.D. Anderson Cancer Center, Houston, Texas 77030 (United States); Department of Radiation Oncology, M. D. Anderson Cancer Center Orlando, Orlando, Florida 32806 (United States); Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York 10021 (United States); Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado 80045 (United States); Department of Radiation Physics, Princess Margaret Hospital, University of Toronto, Toronto, Ontario, M5G 2M9 (Canada); Department of Radiation Oncology, UCSF Comprehensive Cancer Center, 1600 Divisadero St., Suite H 1031, San Francisco, California 94143-1708 (United States); Department of Radiation Oncology, Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Radiation Oncology, Duke University, Durham, North Carolina 27710 (United States)

2012-04-15T23:59:59.000Z

215

Quality assurance (QA) plan for the transportation and receipt of transuranic (TRU) waste  

SciTech Connect (OSTI)

The Department of Energy (DOE) Albuquerque Operations (AL) Office of Projects and Energy Programs has been assigned the responsibility for administration of the disposal of Contact-Handled (CH) Transuranic (TRU) contaminated material (waste) from generator/storage sites of the United States defense programs that are operated by the DOE. This responsibility encompasses all activities associated with the certification of TRU waste and the transportation, receipt and disposal of that waste at the Waste Isolation Pilot Plant (WIPP). The WIPP is located near Carlsbad, New Mexico and is being developed under the management of the DOE WIPP Project Office (WPO). The DOE/WPO is a branch of the DOE/AL and has been delegated overall responsibility for all aspects of the WIPP program. This report describes the quality assurance plan for the TRU waste transportation and receipt of waste.

Not Available

1990-02-01T23:59:59.000Z

216

Recommended reforms in codes and standards, quality assurance, and engineering practices for competitive liquid metal nuclear power plants  

SciTech Connect (OSTI)

Recommendations are presented on LMFBR: codes and standards; quality assurance requirements and practices; and engineering practices. (JDB)

Harms, W.O. (comp.)

1986-04-01T23:59:59.000Z

217

Quality Assurance Needs for Modern Image-Based Radiotherapy: Recommendations From 2007 Interorganizational Symposium on 'Quality Assurance of Radiation Therapy: Challenges of Advanced Technology'  

SciTech Connect (OSTI)

This report summarizes the consensus findings and recommendations emerging from 2007 Symposium, 'Quality Assurance of Radiation Therapy: Challenges of Advanced Technology.' The Symposium was held in Dallas February 20-22, 2007. The 3-day program, which was sponsored jointly by the American Society for Therapeutic Radiology and Oncology (ASTRO), American Association of Physicists in Medicine (AAPM), and National Cancer Institute (NCI), included >40 invited speakers from the radiation oncology and industrial engineering/human factor communities and attracted nearly 350 attendees, mostly medical physicists. A summary of the major findings follows. The current process of developing consensus recommendations for prescriptive quality assurance (QA) tests remains valid for many of the devices and software systems used in modern radiotherapy (RT), although for some technologies, QA guidance is incomplete or out of date. The current approach to QA does not seem feasible for image-based planning, image-guided therapies, or computer-controlled therapy. In these areas, additional scientific investigation and innovative approaches are needed to manage risk and mitigate errors, including a better balance between mitigating the risk of catastrophic error and maintaining treatment quality, complimenting the current device-centered QA perspective by a more process-centered approach, and broadening community participation in QA guidance formulation and implementation. Industrial engineers and human factor experts can make significant contributions toward advancing a broader, more process-oriented, risk-based formulation of RT QA. Healthcare administrators need to appropriately increase personnel and ancillary equipment resources, as well as capital resources, when new advanced technology RT modalities are implemented. The pace of formalizing clinical physics training must rapidly increase to provide an adequately trained physics workforce for advanced technology RT. The specific recommendations of the Symposium included the following. First, the AAPM, in cooperation with other advisory bodies, should undertake a systematic program to update conventional QA guidance using available risk-assessment methods. Second, the AAPM advanced technology RT Task Groups should better balance clinical process vs. device operation aspects-encouraging greater levels of multidisciplinary participation such as industrial engineering consultants and use-risk assessment and process-flow techniques. Third, ASTRO should form a multidisciplinary subcommittee, consisting of physician, physicist, vendor, and industrial engineering representatives, to better address modern RT quality management and QA needs. Finally, government and private entities committed to improved healthcare quality and safety should support research directed toward addressing QA problems in image-guided therapies.

Williamson, Jeffrey F. [Virginia Commonwealth University, Richmond, VA (United States)], E-mail: jwilliamson@mcvh-vcu.edu; Dunscombe, Peter B. [University of Calgary, Calgary, AB (Canada); Sharpe, Michael B. [Princess Margaret Hospital, Toronto, ON (Canada); Thomadsen, Bruce R. [University of Wisconsin, Madison, WI (United States); Purdy, James A. [University of California-Davis, Sacramento, CA (United States); Deye, James A. [National Cancer Institute, Bethesda, MD (United States)

2008-05-01T23:59:59.000Z

218

The effect of job performance aids on quality assurance  

SciTech Connect (OSTI)

Job performance aids (JPAs) have been studied for many decades in a variety of disciplines and for many different types of tasks, yet this is the first known research experiment using JPAs in a quality assurance (QA) context. The objective of this thesis was to assess whether a JPA has an effect on the performance of a QA observer performing the concurrent dual verification technique for a basic assembly task. The JPA used in this study was a simple checklist, and the design borrows heavily from prior research on task analysis and other human factors principles. The assembly task and QA construct of concurrent dual verification are consistent with those of a high consequence manufacturing environment. Results showed that the JPA had only a limited effect on QA performance in the context of this experiment. However, there were three important and unexpected findings that may draw interest from a variety of practitioners. First, a novel testing methodology sensitive enough to measure the effects of a JPA on performance was created. Second, the discovery that there are different probabilities of detection for different types of error in a QA context may be the most far-reaching results. Third, these results highlight the limitations of concurrent dual verification as a control against defects. It is hoped that both the methodology and results of this study are an effective baseline from which to launch future research activities.

Fosshage, Erik

2014-06-01T23:59:59.000Z

219

Global Threat Reduction Initiative Fuel-Thermo-Physical Characterization Project Quality Assurance Plan  

SciTech Connect (OSTI)

The charter of the Fuel Thermo-Physical Characterization Project is to ready Pacific Northwest National Laboratory (PNNL) facilities and processes for the receipt of unirradiated and irradiated low enriched uranium (LEU) molybdenum (U-Mo) fuel element samples, and to perform analysis to support the Global Threat Reduction Initiative conversion program. PNNL’s support for the program will include the establishment of post-irradiation examination processes, including thermo-physical properties, unique to the U.S. Department of Energy laboratories. These processes will ultimately support the submission of the base fuel qualification (BFQ) to the U.S. Nuclear Regulatory Commission (NRC) and revisions to High Performance Research Reactor Safety Analysis Reports to enable conversion from highly enriched uranium to LEU fuel. This quality assurance plan (QAP) provides the quality assurance requirements and processes that support the NRC BFQ. This QAP is designed to be used by project staff, and prescribes the required management control elements that are to be met and how they are implemented. Additional controls are captured in Fuel Thermo-Physical Characterization Project plans, existing procedures, and procedures to be developed that provide supplemental information on how work is conducted on the project.

Pereira, Mario M.; Slonecker, Bruce D.

2012-06-01T23:59:59.000Z

220

Quality Jobs Program (Louisiana)  

Broader source: Energy.gov [DOE]

The Quality Jobs Program provides a cash rebate to companies that create well-paid jobs and promote economic development. Benefits include a 5-6% cash rebate of annual gross payroll for new,...

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM | Department of...  

Broader source: Energy.gov (indexed) [DOE]

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM System Maintenance Checklist SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM More...

222

Recommendations for a Software Quality Assurance Plan for the CMR Facility at LANL  

SciTech Connect (OSTI)

The Nuclear Materials Technology (NMT) organizations 1 and 3 within the Chemical and Metallurgical Research (CMR) facility at the Los Alamos National Laboratory are working to achieve Waste Isolation Pilot Plant (WIPP) certification to enable them to transport their TRU waste to WIPP. This document is intended to provide not only recommendations to address the necessary software quality assurance activities to enable the NMT-1 and NMT-3 organizations to be WIPP compliant but is also meant to provide a template for the final Software Quality Assurance Plan (SQAP). This document specifically addresses software quality assurance for all software used in support of waste characterization and analysis. Since NMT-1 and NMT-3 currently have several operational software products that are used for waste characterization and analysis, these software quality assurance recommendations apply to the operations, maintenance and retirement of the software and the creation and development of any new software required for waste characterization and analyses.

Adams, K.; Matthews, S. D.; McQueen, M. A.

1998-10-01T23:59:59.000Z

223

The Soils and Groundwater – EM-20 S&T Roadmap Quality Assurance Project Plan  

SciTech Connect (OSTI)

The Soils and Groundwater – EM-20 Science and Technology Roadmap Project is a U.S. Department of Energy, Office of Environmental Management-funded initiative designed to develop new methods, strategies and technology for characterizing, modeling, remediating, and monitoring soils and groundwater contaminated with metals, radionuclides, and chlorinated organics. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by EM-20 Roadmap Project staff.

Fix, N. J.

2008-02-11T23:59:59.000Z

224

Fluor Hanford, Inc. Groundwater and Technical Integration Support (Master Project) Quality Assurance Management Plan  

SciTech Connect (OSTI)

The scope of the Fluor Hanford, Inc. Groundwater and Technical Integration Support (Master Project) is to provide technical and integration support to Fluor Hanford, Inc., including operable unit investigations at 300-FF-5 and other groundwater operable units, strategic integration, technical integration and assessments, remediation decision support, and science and technology. This Quality Assurance Management Plan provides the quality assurance requirements and processes that will be followed by the Fluor Hanford, Inc. Groundwater and Technical Integration Support (Master Project).

Fix, N. J.

2008-02-20T23:59:59.000Z

225

E-Print Network 3.0 - assurance program argonne Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

argonne Search Powered by Explorit Topic List Advanced Search Sample search results for: assurance program argonne Page: << < 1 2 3 4 5 > >> 1 Summary Site Environmental Report for...

226

E-Print Network 3.0 - assurance program guidelines Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Grants Administration Summary: and interpretation of PHS Policy, supports educational programs, and monitors compliance with the Policy by Assured... guidelines for research funded...

227

Risk assessment in the DOE Assurance Program for Remedial Action  

SciTech Connect (OSTI)

This document provides information obtained during the performance of risk assessment tasks in support of the Assurance Program for Remedial Action (APRA) sponsored by the Office of Operational Safety of the Department of Energy. We have presented a method for the estimation of projected health effects at properties in the vicinity of uranium mill tailing piles due to transported tailings or emissions from the piles. Because radon and radon daughter exposure is identified as the principal factor contributing to health effects at such properties, the basis for estimating lung cancer risk as a result of such exposure is discussed in detail. Modeling of health risk due to a secondary pathway, ingestion of contaminated, home-grown food products, is also discussed since it is a potentially important additional source of exposure in certain geographic locations. Risk assessment methods used in various mill tailings reports are reviewed. The protocols for radiological surveys conducted in DOE-sponsored remedial action programs are critically reviewed with respect to their relevance to the needs of health risk estimation. The relevance of risk assessment to the APRA program is discussed briefly.

Marks, S.; Cross, F.T.; Denham, D.H.; Kennedy, W.E.; Stenner, R.D.

1985-08-01T23:59:59.000Z

228

Service Quality Assurance 08/08/08 INMGT 220 001  

E-Print Network [OSTI]

. Course Objectives An introduction to quality, quality systems, and quality management through a survey) in Technology Management from Indiana State Univ., specialization in manufacturing systems [planning to receive · Statistical Process Control (partial) Textbook The Management and Control of Quality by Evans and Lindsay 6th

Wu, Mingshen

229

Quality Assurance Plan for Field Activities at the Natural and Accelerated Bioremediation Research (NABIR) Field Research Center (FRC), Oak Ridge, Tennessee  

SciTech Connect (OSTI)

The Environmental Sciences Division (ESD) at Oak Ridge National Laboratory (ORNL) has established a Natural and Accelerated Bioremediation Research (NABIR) program Field Research Center (FRC) for the U.S. Department of Energy (DOE) Office of Biological and Environmental Research. The FRC is located in Bear Creek Valley within the Y-12 Plant area of responsibility on DOE's Oak Ridge Reservation in Tennessee. The NABIR program is a long-term effort designed to increase the understanding of fundamental biogeochemical processes that would allow the use of bioremediation approaches for cleaning up DOE's contaminated legacy waste sites. The FRC provides a site for investigators in the NABIR program to conduct research and obtain samples related to in situ bioremediation. The FRC is integrated with existing and future laboratory and field research and provides a means of examining the biogeochemical processes that influence bioremediation under controlled small-scale field conditions. This Quality Assurance Plan (QAP) documents the quality assurance protocols for field and laboratory activities performed by the FRC staff. It supplements the requirements in the ORNL Nuclear Quality Assurance Program and the ESD Quality Assurance Program. The QAP addresses the requirements in Title 10 CFR, Part 830 Subpart A, ''Quality Assurance Requirements'', using a graded approach appropriate for Research and Development projects based on guidance from ''Implementation Guide for Quality Assurance Programs for Basic and Applied Research'' (DOE-ER-STD-6001-92). It also supports the NABIR FRC Management Plan (Watson and Quarles 2000a) which outlines the overall procedures, roles and responsibilities for conducting research at the FRC. The QAP summarizes the organization, work activities, and qualify assurance and quality control protocols that will be used to generate scientifically defensible data at the FRC. The QAP pertains to field measurements and sample collection conducted by the FRC to characterize the site and in support of NABIR-funded investigations at the FRC. NABIR investigators who collect their own samples or measurements at the FRC will be responsible for developing their own data quality assurance protocol. Notably, this QAP will be of direct benefit to NABIR investigators who will be provided with and use the documented quality data about the FRC to support their investigations.

Brandt, C.C.

2002-02-28T23:59:59.000Z

230

Quality Jobs Investment Program (Oklahoma)  

Broader source: Energy.gov [DOE]

The Oklahoma Quality Jobs Program allows qualifying businesses which are creating new quality jobs to receive a special incentive to locate or expand in Oklahoma.

231

Approved Module Information for PH3704, 2014/5 Module Title/Name: Quality Assured Pharmaceutical  

E-Print Network [OSTI]

and processes, including the use of Standard Operating Procedures, Good Laboratory Practice, Good Pharmaceutical Technology Module Code: PH3704 School: Life and Health Sciences Module Type: Standard Module New Module of these materials. · To describe the role of quality assurance in the maintenance of the quality of pharmaceutical

Neirotti, Juan Pablo

232

Developing Quality Assurance Processes for Image-Guided Adaptive Radiation Therapy  

SciTech Connect (OSTI)

Quality assurance has long been implemented in radiation treatment as systematic actions necessary to provide adequate confidence that the radiation oncology service will satisfy the given requirements for quality care. The existing reports from the American Association of Physicists in Medicine Task Groups 40 and 53 have provided highly detailed QA guidelines for conventional radiotherapy and treatment planning. However, advanced treatment processes recently developed with emerging high technology have introduced new QA requirements that have not been addressed previously in the conventional QA program. Therefore, it is necessary to expand the existing QA guidelines to also include new considerations. Image-guided adaptive radiation therapy (IGART) is a closed-loop treatment process that is designed to include the individual treatment information, such as patient-specific anatomic variation and delivered dose assessed during the therapy course in treatment evaluation and planning optimization. Clinical implementation of IGART requires high levels of automation in image acquisition, registration, segmentation, treatment dose construction, and adaptive planning optimization, which brings new challenges to the conventional QA program. In this article, clinical QA procedures for IGART are outlined. The discussion focuses on the dynamic or four-dimensional aspects of the IGART process, avoiding overlap with conventional QA guidelines.

Yan Di [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States)], E-mail: dyan@beaumont.edu

2008-05-01T23:59:59.000Z

233

Suspect/Counterfeit Items Guide for Use with 10 CFR 830 Subpart A, Quality Assurance Requirements, and DOE O 414.1B, Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Guide provides guidance to assist DOE/NNSA and its contractors in mitigating the safety threat of suspect/counterfeit items (S/CIs). Cancels DOE G 440.1-6, Implementation Guide for use with Suspect/Counterfeit Items Requirements of DOE O 440.1, Worker Protection Management; 10 CFR 830.120; and DOE O 5700.6C, Quality Assurance, dated 6-30-97. Canceled by DOE G 414.1-2B.

2004-11-03T23:59:59.000Z

234

Pacific Northwest National Laboratory Apatite Investigation at the 100-NR-2 Quality Assurance Project Plan  

SciTech Connect (OSTI)

This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by staff working on the 100-NR-2 Apatite Project. The U.S. Department of Energy, Fluor Hanford, Inc., Pacific Northwest National Laboratory, and the Washington Department of Ecology agreed that the long-term strategy for groundwater remediation at 100-N would include apatite sequestration as the primary treatment, followed by a secondary treatment. The scope of this project covers the technical support needed before, during, and after treatment of the targeted subsurface environment using a new high-concentration formulation.

Fix, N. J.

2008-03-28T23:59:59.000Z

235

Application of EPA quality assurance procedures to a soil characterization study at the DOE Nevada Test Site  

SciTech Connect (OSTI)

The transfer, modification, and application of well formulated and tested quality assurance (QA) procedures from one project to another deserves consideration. The use of a proven QA program design could result in cost savings and the collection of data with a greater degree of confidence. To test this thesis, a QA program, originally developed for large nationwide Environmental Protection Agency (EPA) programs, was adapted and implemented in a site characterization study at the Department of Energy (DOE) Nevada Test Site to ensure that laboratory data satisfied pre-determined measurement quality objectives (MQOs). The QA Program was adapted from EPA programs such as the National Acid Precipitation Assessment Program, the Environmental Monitoring and Assessment Program, and to a lesser degree, the Comprehensive Environmental Recovery, Compensation and Liability Act (CERCLA) Program. The QA design adopted the batch or lot concept, in which samples are organized into groups of quality samples (non-blinds, blinds, and double-blinds), which were included in each batch to evaluate and control measurement uncertainty and to address sample preparation. Detectability was assessed using instrument detection limits and precision data for low-concentration samples. Precision was assessed using data from reference samples under a two-tiered system based on concentration ranges. Accuracy was investigated in terms of bias with respect to reference values. The results showed that QA concepts developed for previous nationwide EPA programs were successfully adapted for the site-specific DOE project.

Snyder, K.E.; Byers, G.E.; Van Remortel, R.D. [Lockheed-Martin Environmental Systems and Technologies Co., Las Vegas, NV (United States); Gustafson, D.L. [Raytheon Services Nevada, Las Vegas, NV (United States)

1995-12-01T23:59:59.000Z

236

The Waste Management Quality Assurance Implementing Management Plan (QAIMP)  

E-Print Network [OSTI]

QA Program, the applicable QA requirements, and the responsibility for the implementationQA capability as determined by evaluation of the facilities and implementation of the QA program.QA personnel and having line authority for the implementation of the QA program.

Albert editor, R.

2009-01-01T23:59:59.000Z

237

Implementation of test for quality assurance in nuclear medicine gamma camera  

SciTech Connect (OSTI)

In nuclear medicine (NM) over 90% of procedures are performed for diagnostic purposes. To ensure adequate diagnostic quality of images and the optimization of the doses received by patients originated from the radioactive material is essential for regular monitoring and equipment performance through a quality assurance program (QAP). The QAP consists of 15 proposed performance tomographic and not tomographic gamma camera (GC) tests, and is based on recommendations of international organizations. We describe some results of the performance parameters of QAP applied to a GC model e.cam Siemens, of the Department of NM of the National Cancer Institute of Mexico (INCan). The results were: (1) The average intrinsic spatial resolution (R{sub in}) was 4.67 {+-} 0.25 mm at the limit of acceptance criterion of 4.4 mm. (2) The sensitivity extrinsic (S{sub ext}), with maximum variations of 1.8% (less than 2% which is the criterion of acceptance). (3) Rotational Uniformity (U{sub rot}), with values of integral uniformity (IU) in the useful field of view detector (UFOV), with maximum percentage change of 0.97% and monthly variations equal angles, ranging from 0.13 to 0.99% less than 1%. (4) The displacement of the center of rotation (DCOR), indicated a maximum deviation of 0.155 {+-} 0.039 mm less than 4.795 mm, an absolute deviation of less than 0.5 where pixel 0.085 pixel is suggested, the criteria are assigned to low-energy collimator high resolution. (5) In tomographic uniformity (U{sub tomo}), UI values (%) and percentage noise level (rms%) were 7.54 {+-} 1.53 and 4.18 {+-} 1.69 which are consistent with the limits of acceptance of 7.0-12.0% and 3.0-6.0% respectively. The smallest cold sphere has a diameter of 11.4 mm. The implementation of a QAP allows for high quality diagnostic images, optimization of the doses given to patients, a reduction of exposure to occupationally exposed workers (POE, by its Spanish acronym), and generally improves the productivity of the service. This proposal can be used to develop a similar QAP in other facilities and may serve as a precedent for the proposed regulations for quality assurance (QA) teams in MN.

Montoya Moreno, A.; Rodriguez Laguna, A.; Trujillo Zamudio, Flavio E [Department of Nuclear Medicine, National Cancer Institute San Fernando Avenue No.22, Col. Section XVI (Mexico)

2012-10-23T23:59:59.000Z

238

Potsdam University's Approach to Quality Assurance in Higher Education A comprehensive and systematic quality management system is characteristic for education and  

E-Print Network [OSTI]

and systematic quality management system is characteristic for education and training at Potsdam the quality management system is undergoing institutional evaluation: the German "System of the university's quality assurance system. At the same time the faculties are accountable

Potsdam, Universität

239

ARM - Data Quality Program  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation InInformation InExplosionAnnouncements Media Contact Hanna Goss7, 2015Quality Program DQ

240

Quality Assurance 9 2005 Site environmental report9-  

E-Print Network [OSTI]

throughout the entire organization. The purpose of the BNL Quality Management (QM) System is to imple- ment QM methodology throughout the various Laboratory management systems and associated processes- ployed as an integrated system of management activities. These activities involve planning

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Quality assurance of solar thermal systems with the ISFH-Input/Output-Procedure  

E-Print Network [OSTI]

Quality assurance of solar thermal systems with the ISFH- Input/Output-Procedure Peter Paerisch different solar systems. The simulation model was validated with measured data. The deviation between meas * Tel. +49 (0)5151-999503, Fax: +49 (0)5151-999500, Email: paerisch@isfh.de Abstract Input/Output

242

Quality Assurance Guidelines for Superior Vena Cava Stenting in Malignant Disease  

SciTech Connect (OSTI)

Superior vena cava stenting for the treatment of malignant superior vena cava obstruction is now well established. It offers simple, rapid, and safe palliation of a distressing and potentially fatal complication of mediastinal malignant disease and compares very favorably with standard therapies such as chemotherapy and radiotherapy. The following are quality assurance guidelines for superior vena cava stenting.

Uberoi, Raman [John Radcliffe Hospital, Department of Radiology (United Kingdom)], E-mail: raman.uberoi@orh.nhs.uk

2006-06-15T23:59:59.000Z

243

Bio/Pharmaceutical Quality Assurance Supervisor/Manager Open Applicant Pool BioMARC/IDRC/OVPR/CSU  

E-Print Network [OSTI]

Bio/Pharmaceutical Quality Assurance Supervisor/Manager Open Applicant Pool Bio at the end of this document. The jobs covered in this pool include: LS0054 ­ Quality Assurance Supervisor/Manager Job description of the QA Supervisor/Manager position: This position requires strong knowledge

Stephens, Graeme L.

244

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Software Configuration...  

Broader source: Energy.gov (indexed) [DOE]

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Software Configuration Management Checklist SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Software Configuration Management...

245

Quality Assurance 9 2007 Site environmental report9-  

E-Print Network [OSTI]

governing work, and extends throughout the entire organization. The purpose of the BNL Quality Management (QM) System is to implement QM methodology throughout the various Laboratory management systems is de- ployed as an integrated system of management activities. These activities involve planning

246

Quality Assurance 9 2003 SITE ENVIRONMENTAL REPORT9-1  

E-Print Network [OSTI]

organization. The purpose of the BNL Quality Management (QM) System is to imple- ment QM methodology throughout the vari- ous BNL management systems and associated processes to: Plan and perform BNL operations is de-For environmental monitoring, QA ployed as an integrated system of management activities

Homes, Christopher C.

247

Quality Assurance 9 2004 SITE ENVIRONMENTAL REPORT9-1  

E-Print Network [OSTI]

of the BNL Quality Management (QM) System is to implement QM methodol- ogy throughout the various BNL management systems and associated processes, in order to: Plan and perform BNL operations in a reliable monitoring, QA is de- ployed as an integrated system of management activities. These activities involve

248

Quality Assurance 9 2006 Site environmental report9-  

E-Print Network [OSTI]

throughout the entire organization. The purpose of the BNL Quality Management (QM) System is to imple- ment QM methodology throughout the various Laboratory management systems and associated processes as an integrated system of management activities. These activities involve planning, implementation, control

249

Facility Software Quality Assurance for Capital Project Decisions RM  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power SystemsResourcesFLASH2011-11-OPAMFY 2007 Total System12 EEREFacility Software Quality

250

Impact of Quality Assurance Rounds in a Canadian Radiation Therapy Department  

SciTech Connect (OSTI)

Purpose: Quality assurance (QA) programs aim to identify inconsistencies that may compromise patient care. Radiation treatment planning is a well-documented source of variation in radiation oncology, leading many organizations to recommend the implementation of QA rounds in which radiation therapy plans are peer reviewed. This study evaluates the outcome of QA rounds that have been conducted by a radiation therapy department since 2004. Methods and Materials: Prospectively documented records of QA rounds, from 2004 to 2010, were obtained. During rounds, randomly selected radiation therapy plans were peer reviewed and assigned a grade of A (adequate), B (minor suggestions of change to a plan for a future patient), or C (significant change required before the next fraction). The proportion of plans that received each recommendation was calculated, and the relationship between recommendations for each plan, tumor site, and mean years of experience of the radiation oncologist (RO) were explored. Chart reviews were performed for each plan that received a C. Results: During the study period, 1247 plans were evaluated; 6% received a B and 1% received a C. The mean RO years of experience were lower for plans graded C versus those graded A (P=.02). The tumor sites with the highest proportion of plans graded B or C were gastrointestinal (14%), lung (13%), and lymphoma (8%). The most common reasons for plans to receive a grade of C were inadequate target volume coverage (36%), suboptimal dose or fractionation (27%), errors in patient setup (27%), and overtreatment of normal tissue (9%). Conclusions: This study demonstrated that QA rounds are feasible and an important element of a radiation therapy department's QA program. Through peer review, plans that deviate from a department's expected standard can be identified and corrected. Additional benefits include identifying patterns of practice that may contribute to inconsistencies in treatment planning and the continuing education of staff members who attend.

Lefresne, Shilo; Olivotto, Ivo A.; Joe, Howard; Blood, Paul A. [Radiotherapy Department, BC Cancer Agency, Vancouver Island Centre, Vancouver, British Columbia (Canada) [Radiotherapy Department, BC Cancer Agency, Vancouver Island Centre, Vancouver, British Columbia (Canada); Radiotherapy Department, University of British Columbia, Vancouver, British Columbia (Canada); Olson, Robert A., E-mail: rolson2@bccancer.bc.ca [Radiotherapy Department, University of British Columbia, Vancouver, British Columbia (Canada); Radiotherapy Department, BC Cancer Agency, Centre for the North, Prince George, British Columbia (Canada)

2013-03-01T23:59:59.000Z

251

PNNL Apatite Investigation at 100-NR-2 Quality Assurance Project Plan  

SciTech Connect (OSTI)

In 2004, the U.S. Department of Energy, Fluor Hanford, Inc., Pacific Northwest National Laboratory (PNNL), and the Washington Department of Ecology agreed that the long-term strategy for groundwater remediation at the 100-N Area would include apatite sequestration as the primary treatment, followed by a secondary treatment if necessary. Since then, the agencies have worked together to agree on which apatite sequestration technology has the greatest chance of reducing strontium-90 flux to the Columbia River. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by staff working on the PNNL Apatite Investigation at 100-NR-2 Project. The plan is designed to be used exclusively by project staff.

Fix, N. J.

2009-04-02T23:59:59.000Z

252

The CHPRC Groundwater and Technical Integration Support (Master Project) Quality Assurance Management Plan  

SciTech Connect (OSTI)

The scope of the CH2M Hill Plateau Remediation Company, LLC (CHPRC) Groundwater and Technical Integration Support (Master Project) is for Pacific Northwest National Laboratory staff to provide technical and integration support to CHPRC. This work includes conducting investigations at the 300-FF-5 Operable Unit and other groundwater operable units, and providing strategic integration, technical integration and assessments, remediation decision support, and science and technology. The projects under this Master Project will be defined and included within the Master Project throughout the fiscal year, and will be incorporated into the Master Project Plan. This Quality Assurance Management Plan provides the quality assurance requirements and processes that will be followed by the CHPRC Groundwater and Technical Integration Support (Master Project) and all releases associated with the CHPRC Soil and Groundwater Remediation Project. The plan is designed to be used exclusively by project staff.

Fix, N. J.

2009-04-03T23:59:59.000Z

253

Assessment of Quality Assurance Measures for Radioactive Material Transport Packages not Requiring Competent Authority Design Approval - 13282  

SciTech Connect (OSTI)

The majority of transports of radioactive materials are carried out in packages which don't need a package design approval by a competent authority. Low-active radioactive materials are transported in such packages e.g. in the medical and pharmaceutical industry and in the nuclear industry as well. Decommissioning of NPP's leads to a strong demand for packages to transport low and middle active radioactive waste. According to IAEA regulations the 'non-competent authority approved package types' are the Excepted Packages and the Industrial Packages of Type IP-1, IP-2 and IP-3 and packages of Type A. For these types of packages an assessment by the competent authority is required for the quality assurance measures for the design, manufacture, testing, documentation, use, maintenance and inspection (IAEA SSR 6, Chap. 306). In general a compliance audit of the manufacturer of the packaging is required during this assessment procedure. Their regulatory level in the IAEA regulations is not comparable with the 'regulatory density' for packages requiring competent authority package design approval. Practices in different countries lead to different approaches within the assessment of the quality assurance measures in the management system as well as in the quality assurance program of a special package design. To use the package or packaging in a safe manner and in compliance with the regulations a management system for each phase of the life of the package or packaging is necessary. The relevant IAEA-SSR6 chap. 801 requires documentary verification by the consignor concerning package compliance with the requirements. (authors)

Komann, Steffen; Groeke, Carsten; Droste, Bernhard [BAM Federal Institute for Materials Research and Testing, Unter den Eichen 44-46, 12203 Berlin (Germany)] [BAM Federal Institute for Materials Research and Testing, Unter den Eichen 44-46, 12203 Berlin (Germany)

2013-07-01T23:59:59.000Z

254

Total Quality Commissioning for HVAC Systems to Assure High Performance Throughout the Whole Life Cycle  

E-Print Network [OSTI]

TOTAL QUALITY COMMISSIONING FOR HVAC SYSTEMS TO ASSURE HIGH PERFORMANCE THROUGHOUT THE WHOLE LIFE CYCLE By: Grahame E. Maisey, P.E., and Beverly Milestone, LEED AP Building Services Consultants INTRODUCTION Current HVAC systems... are not coming close to approaching life cycle performance expectations for energy, operation and maintenance, occupant comfort and productivity and longevity. HVAC systems in buildings claiming to be sustainable, with integrated, energy conscious design...

Maisey, G.; Milestone, B.

2005-01-01T23:59:59.000Z

255

A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography  

SciTech Connect (OSTI)

Purpose: Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition, the dependence of objective Fourier-based IQ metrics on direction and position in 3D volumes was investigated for CBCT. Methods: The authors designed a dedicated QA phantom 10 cm in length consisting of five compartments, each with a diameter of 10 cm, and an optional extension ring 16 cm in diameter. A homogeneous section of water-equivalent material allows measuring CT value accuracy, image noise and uniformity, and multidimensional global and local noise power spectra (NPS). For the quantitative determination of 3D high-contrast spatial resolution, the modulation transfer function (MTF) of centrally and peripherally positioned aluminum spheres was computed from edge profiles. Additional in-plane and axial resolution patterns were used to assess resolution qualitatively. The characterization of low-contrast detectability as well as CT value linearity and artifact behavior was tested by utilizing sections with soft-tissue-equivalent and metallic inserts. For an automated QA procedure, a phantom detection algorithm was implemented. All tests used in the dedicated QA program were initially verified in simulation studies and experimentally confirmed on a clinical dental CBCT system. Results: The automated IQ evaluation of volume data sets of the dental CBCT system was achieved with the proposed phantom requiring only one scan for the determination of all desired parameters. Typically, less than 5 min were needed for phantom set-up, scanning, and data analysis. Quantitative evaluation of system performance over time by comparison to previous examinations was also verified. The maximum percentage interscan variation of repeated measurements was less than 4% and 1.7% on average for all investigated quality criteria. The NPS-based image noise differed by less than 5% from the conventional standard deviation approach and spatially selective 10% MTF values were well comparable to subjective results obtained with 3D resolution pattern. Determining only transverse spatial resolution and global noise behavior in the central field of measurement turned out to be insufficient. Conclusions: The proposed framework transfers QA routines employed in conventional CT in an advanced version to CBCT for fully automated and time-efficient evaluation of technical equipment. With the modular phantom design, a routine as well as an expert version for assessing IQ is provided. The QA program can be used for arbitrary CT units to evaluate 3D imaging characteristics automatically.

Steiding, Christian; Kolditz, Daniel; Kalender, Willi A., E-mail: willi.kalender@imp.uni-erlangen.de [Institute of Medical Physics, University of Erlangen-Nürnberg, Henkestraße 91, 91052 Erlangen, Germany and CT Imaging GmbH, 91052 Erlangen (Germany)

2014-03-15T23:59:59.000Z

256

Microsoft Word - INL MIS-12-25696 Fuels_LWRS_Program_Plan R1...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

QA Quality Assurance QAPD Quality Assurance Program Document R&D Research and Development RIA Reactivity Initiated Accident SAD Selected area diffraction SCC Stress Corrosion...

257

Introduction of Break-Out Session 2 of the 2011 International PV Module Quality Assurance Forum(Presentation)  

SciTech Connect (OSTI)

This presentation outlines the goals and specific tasks of break-out session 2 of the 2011 International PV Module Quality Assurance Forum, along with a review of accelerated stress tests used for photovoltaics (PV).

Wohlgemuth, J.; Kurtz, S.; Sample, T.; Yamamichi, M.

2011-07-01T23:59:59.000Z

258

Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The purpose of the Order is to ensure that DOE, including NNSA, products and services meet or exceed customers’ requirements and expectations. Cancels DOE O 414.1C. Adm Chg 1, 5-8-13

2011-04-25T23:59:59.000Z

259

Assurances - Non-Construction Programs | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energyon ArmedWaste andAccess to OUO Access toEnergy 5 BTOoftheA CaseTechnicalAssurances

260

Summary report on the Solar Consumer Assurance Network (SOLCAN) Program Planning Task in the southern region  

SciTech Connect (OSTI)

The goal of the SOLCAN Program Planning Task is to assist in the development, at the state and local levels, of consumer assurance approaches that will support the accelerated adoption and effective use of new products promoted by government incentives to consumers to meet our nation's energy needs. The task includes state-conducted evaluations and state SOLCAN meetings to identify consumer assurance mechanisms, assess their effectiveness, and identify and describe alternative means for strengthening consumer and industry assurance in each state. Results of the SOLCAN process are presented, including: a Solar Consumer Protection State Assessment Guide; State Solar Consumer Assurance Resources for Selected States; State Solar Consumer Protection Assessment Interviews for Florida; and state SOLCAN meeting summaries and participants. (LEW)

Browne, M. B. [comp.] [comp.

1981-03-15T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Distribution power quality measurement program  

SciTech Connect (OSTI)

This paper describes different facets of a distribution system power quality monitoring program with analysis of data from 222 different sites during the project`s first year. Information regarding the site selection process is provided. Preliminary results for voltage harmonic distortion and sags are presented from the project`s study population of feeders, including the use of novel power quality analysis techniques.

Sabin, D.D.; Grebe, T.E.; Melhorn, C.J. [Electrotek Concepts, Inc., Knoxville, TN (United States); Sundaram, A. [Electric Power Research Inst., Palo Alto, CA (United States)

1995-12-31T23:59:59.000Z

262

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Software Design...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Software Design Checklist SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Software Design Checklist This checklist is intended to...

263

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Preacceptance...  

Broader source: Energy.gov (indexed) [DOE]

PROGRAM: Preacceptance Checklist Security Issues SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Preacceptance Checklist Security Issues The following checklist is intended to...

264

assurance program description: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

workforce at LANL. DataImpacts LANL Funding: These Postdocs are paid from programmatic funding within 2 Program Description Queen's University Computer Technologies and...

265

Quality assurance guidance for TRUPACT-II (Transuranic Package Transporter-II) payload control  

SciTech Connect (OSTI)

The Transuranic Package Transporter-II (TRUPACT-II) Safety Analysis Report for Packaging (SARP) approved by the Nuclear Regulatory Commission (NRC), discusses authorized methods for payload control in Appendix 1.3.7 and the Quality Assurance (QA) requirements in Section 9.3. Subsection 9.3.2.1 covers maintenance and use of the TRUPACT-II and the specific QA requirements are given in DOE/WIPP 89-012. Subsection 9.3.2.2 covers payload compliance, for which this document was written. 6 refs.

Not Available

1989-10-01T23:59:59.000Z

266

Quality system for the educational activities at the University of Oslo (last update 6 July 2010) QUALITY ASSURANCE SYSTEM FOR THE EDUCATIONAL  

E-Print Network [OSTI]

Quality system for the educational activities at the University of Oslo (last update 6 July 2010) 1 QUALITY ASSURANCE SYSTEM FOR THE EDUCATIONAL ACTIVITIES AT THE UNIVERSITY OF OSLO (last update 6 July 2010............................................................................25 #12;Quality system for the educational activities at the University of Oslo (last update 6 July

Johansen, Tom Henning

267

The 300 Area Integrated Field Research Challenge Quality Assurance Project Plan  

SciTech Connect (OSTI)

Pacific Northwest National Laboratory and a group of expert collaborators are using the U.S. Department of Energy Hanford Site 300 Area uranium plume within the footprint of the 300-FF-5 groundwater operable unit as a site for an Integrated Field-Scale Subsurface Research Challenge (IFRC). The IFRC is entitled Multi-Scale Mass Transfer Processes Controlling Natural Attenuation and Engineered Remediation: An IFRC Focused on the Hanford Site 300 Area Uranium Plume Project. The theme is investigation of multi-scale mass transfer processes. A series of forefront science questions on mass transfer are posed for research that relate to the effect of spatial heterogeneities; the importance of scale; coupled interactions between biogeochemical, hydrologic, and mass transfer processes; and measurements/approaches needed to characterize and model a mass transfer-dominated system. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by the 300 Area IFRC Project. This plan is designed to be used exclusively by project staff.

Fix, N. J.

2009-04-29T23:59:59.000Z

268

Methodology guideline for risk-based application of quality assurance requirements  

SciTech Connect (OSTI)

Augmentation of traditional engineering and safety evaluation methods with probabilistic safety assessment (PSA) models can result in improved safety and more cost-effective operation of commercial nuclear power stations. The US Nuclear Regulatory Commission (NRC) staff has recently published an assessment of the potential for use of PSA methods to assist in focusing utility and NRC staff resources on the areas most critical to overall plant safety. This NRC assessment outlines the current state of PSA technology and its application to regulatory decision making, including the potential for use of PSA for implementation of graded quality assurance. During 1993, the Electric Power Research Institute (EPRI) began work on a project focused on the application of PSA to programmatic areas of nuclear power plant operations, maintenance, and regulation. The project is a broad-scope effort starting with identification of major cost drivers in the nuclear industry and culminating in the application of PSA to selected areas to reduce cost while maintaining or reducing the level of plant risk. This paper summarizes a portion of the EPRI project dealing with the risk ranking of nuclear plant systems, structures, and components (SSCs) and application of graded quality assurance (QA) based on risk significance. The graded QA task was jointly sponsored by EPRI and Entergy`s Grand Gulf nuclear power station.

Bouchey, G.D.; Parkinson, W.J.; Meisner, M.J.; Rahn, F.J.

1994-12-31T23:59:59.000Z

269

Quality assurance for the clinical implementation of kilovoltage intrafraction monitoring for prostate cancer VMAT  

SciTech Connect (OSTI)

Purpose: Kilovoltage intrafraction monitoring (KIM) is a real-time 3D tumor monitoring system for cancer radiotherapy. KIM uses the commonly available gantry-mounted x-ray imager as input, making this method potentially more widely available than dedicated real-time 3D tumor monitoring systems. KIM is being piloted in a clinical trial for prostate cancer patients treated with VMAT (NCT01742403). The purpose of this work was to develop clinical process and quality assurance (QA) practices for the clinical implementation of KIM. Methods: Informed by and adapting existing guideline documents from other real-time monitoring systems, KIM-specific QA practices were developed. The following five KIM-specific QA tests were included: (1) static localization accuracy, (2) dynamic localization accuracy, (3) treatment interruption accuracy, (4) latency measurement, and (5) clinical conditions accuracy. Tests (1)–(4) were performed using KIM to measure static and representative patient-derived prostate motion trajectories using a 3D programmable motion stage supporting an anthropomorphic phantom with implanted gold markers to represent the clinical treatment scenario. The threshold for system tolerable latency is <1 s. The tolerances for all other tests are that both the mean and standard deviation of the difference between the programmed trajectory and the measured data are <1 mm. The (5) clinical conditions accuracy test compared the KIM measured positions with those measured by kV/megavoltage (MV) triangulation from five treatment fractions acquired in a previous pilot study. Results: For the (1) static localization, (2) dynamic localization, and (3) treatment interruption accuracy tests, the mean and standard deviation of the difference are <1.0 mm. (4) The measured latency is 350 ms. (5) For the tests with previously acquired patient data, the mean and standard deviation of the difference between KIM and kV/MV triangulation are <1.0 mm. Conclusions: Clinical process and QA practices for the safe clinical implementation of KIM, a novel real-time monitoring system using commonly available equipment, have been developed and implemented for prostate cancer VMAT.

Ng, J. A. [School of Medicine, University of Sydney, NSW 2006, Australia and School of Physics, University of Sydney, NSW 2006 (Australia); Booth, J. T. [School of Physics, University of Sydney, NSW 2006, Australia and Northern Sydney Cancer Centre, Royal North Shore Hospital, NSW 2065 (Australia); O’Brien, R. T.; Huang, C.-Y.; Keall, P. J., E-mail: paul.keall@sydney.edu.au [School of Medicine, University of Sydney, NSW 2006 (Australia); Colvill, E. [School of Medicine, University of Sydney, NSW 2006, Australia and Northern Sydney Cancer Centre, Royal North Shore Hospital, NSW 2065 (Australia); Poulsen, P. R. [Department of Oncology, Aarhus University Hospital, Nørrebrogade 44, Aarhus C 8000 (Denmark)

2014-11-01T23:59:59.000Z

270

E-Print Network 3.0 - actinide measurement quality Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

4 LA-UR 09-03222 LOS ALAMOS NATIONAL LABORATORY Summary: assurance QAPD Quality Assurance Program Document SNL Sandia National Laboratories SOTERM Actinide Source... on the...

271

Quality Assurance Strategy for Existing Homes: Final Quality Management Primer for High Performing Homes  

SciTech Connect (OSTI)

This guide is designed to help Building America (BA) Teams understand quality management and its role in transitioning from conventional to high performance home building and remodeling. It explains what quality means, the value of quality management systems, the unique need for QMS when building high performing homes, and the first steps to a implementing a comprehensive QMS. This document provides a framework and context for BA teams when they encounter builders and remodelers.

Del Bianco, M.; Taggart, J.; Sikora, J.; Wood, A.

2012-12-01T23:59:59.000Z

272

Quality New Mexico recognizes Community Programs Office  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

CPO receives Pion recognition Quality New Mexico recognizes Community Programs Office LANL has received 14 Pion and Roadrunner recognitions from Quality New Mexico since 1997....

273

Quality Assurance for Residential Retrofit Programs (Text Version...  

Broader source: Energy.gov (indexed) [DOE]

with the contractor. So the next question is what's your opinion of the Home Performance Resource Center from Efficiency First. And I have to say I think highly of Efficiency...

274

EM Quality Assurance Program (EM-QA-001 Revision 0)  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProvedDecember 2005Department ofDOEDisabilityContractors forProcurementsEM-QA-001Office

275

FUEL CYCLE TECHNOLOGIES QUALITY ASSURANCE PROGRAM DOCUMENT | Department of  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA5 &of Energy memoCityTheDepartmentKey FTCPApril 7,

276

Quality Assurance Program Guide - DOE Directives, Delegations, and  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - SeptemberMicroneedlesAdvancedJanuary 13,PuttingEnergyDelegations,

277

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Project Planning...  

Broader source: Energy.gov (indexed) [DOE]

PROGRAM: Project Planning Checklist SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Project Planning Checklist The following checklist is intended to provide system owners, project...

278

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM : Acceptance Checklist...  

Broader source: Energy.gov (indexed) [DOE]

PROGRAM : Acceptance Checklist SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM : Acceptance Checklist The following checklist is intended to provide system owners, project managers,...

279

Quality New Mexico recognizes Community Programs Office  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Quality New Mexico recognizes Community Programs Office March 6, 2012 LOS ALAMOS, New Mexico, March 6, 2012-Los Alamos National Laboratory's Community Programs Office received...

280

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Requirements...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Requirements Management Checklist SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Requirements Management Checklist The following checklist is intended to provide system owners,...

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Quality assurance with the ISFH-Input/Output-Procedure 6-year-experience with 14 solar thermal systems  

E-Print Network [OSTI]

Quality assurance with the ISFH-Input/Output-Procedure 6-year-experience with 14 solar thermal the confidence in solar thermal energy. The so called Input/Output-Procedure is controlling the solar heat systems. The simulation model was validated with measured data and a lot of failures in 11 solar thermal

282

QA program plan plutonium stabilization and handling project W-460  

SciTech Connect (OSTI)

This Quality Assurance Program Plan (QAPP) identifies Project Quality Assurance (QA) program requirements for all parties participating in the design, procurement, demolition, construction, installation, inspection and testing for Project W-460.

SCHULTZ, J.W.

1999-09-02T23:59:59.000Z

283

E-Print Network 3.0 - assurance program description---dwpf Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Computer Technologies and Information Sciences 13 Software Assurance During Maintenance Paul E. Black Summary: Software Assurance During Maintenance Paul E. Black U.S....

284

Quality assurance of asymmetric jaw alignment using 2D diode array  

SciTech Connect (OSTI)

Purpose: A method using a 2D diode array is proposed to measure the junction gap (or overlap) and dose with high precision for routine quality assurance of the asymmetric jaw alignment.Methods: The central axis (CAX) of the radiation field was determined with a 15 × 15 cm{sup 2} photon field at four cardinal collimator angles so that the junction gap (or overlap) can be measured with respect to the CAX. Two abutting fields having a field size of 15 cm (length along the axis parallel to the junction) × 7.5 cm (width along the axis perpendicular to the junction) were used to irradiate the 2D diode array (MapCHECK2) with 100 MU delivered at the photon energy of 6 MV. The collimator was slightly rotated at 15° with respect to the beam central axis to increase the number of diodes effective on the measurement of junction gap. The junction gap and dose measured in high spatial resolution were compared to the conventional methods using an electronic portal imaging device (EPID) and radiochromic film, respectively. In addition, the reproducibility and sensitivity of the proposed method to the measurements of junction gap and dose were investigated.Results: The junction gap (or overlap) and dose measured by MapCHECK2 agreed well to those measured by the conventional methods of EPID and film (the differences ranged from ?0.01 to 0 cm and from ?1.34% to 0.6% for the gap and dose, respectively). No variation in the repeat measurements of the junction gap was found whereas the measurements of junction dose were found to vary in quite a small range over the days of measurement (0.21%–0.35%). While the sensitivity of the measured junction gap to the actual junction gap applied was the ideal value of 1 cm/cm as expected, the sensitivity of the junction dose to the actual junction gap increased as the junction gap (or overlap) decreased (maximum sensitivity: 201.7%/cm).Conclusions: The initial results suggest that the method is applicable for a comprehensive quality assurance of the asymmetric jaw alignment.

Kim, Sun Mo [Department of Medical Physics, Stronach Regional Cancer Centre, Southlake Regional Health Centre, Newmarket, Ontario L3Y 2P9, Canada and Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada)] [Department of Medical Physics, Stronach Regional Cancer Centre, Southlake Regional Health Centre, Newmarket, Ontario L3Y 2P9, Canada and Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada); Chmielewski, Renata; Abbas, Ahmar [Department of Medical Physics, Stronach Regional Cancer Centre, Southlake Regional Health Centre, Newmarket, Ontario L3Y 2P9 (Canada)] [Department of Medical Physics, Stronach Regional Cancer Centre, Southlake Regional Health Centre, Newmarket, Ontario L3Y 2P9 (Canada); Yeung, Ivan W. T.; Moseley, Douglas J. [Department of Medical Physics, Stronach Regional Cancer Centre, Southlake Regional Health Centre, Newmarket, Ontario L3Y 2P9 (Canada) [Department of Medical Physics, Stronach Regional Cancer Centre, Southlake Regional Health Centre, Newmarket, Ontario L3Y 2P9 (Canada); Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada); Department of Radiation Oncology, University of Toronto, Ontario M5G 2M9 (Canada)

2013-12-15T23:59:59.000Z

285

Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance  

SciTech Connect (OSTI)

In this study, a computer-based system for routine quality assurance (QA) of a linear accelerator (linac) was developed by using the dosimetric properties of an amorphous silicon electronic portal imaging device (EPID). An acrylic template phantom was designed such that it could be placed on the EPID and be aligned with the light field of the collimator. After irradiation, portal images obtained from the EPID were transferred in DICOM format to a computer and analyzed using a program we developed. The symmetry, flatness, field size, and congruence of the light and radiation fields of the photon beams from the linac were verified simultaneously. To validate the QA system, the ion chamber and film (X-Omat V2; Kodak, New York, NY) measurements were compared with the EPID measurements obtained in this study. The EPID measurements agreed with the film measurements. Parameters for beams with energies of 6 MV and 15 MV were obtained daily for 1 month using this system. It was found that our QA tool using EPID could substitute for the film test, which is a time-consuming method for routine QA assessment.

Lim, Sangwook, E-mail: medicalphysics@hotmail.com [Department of Radiation Oncology, Kosin University College of Medicine, Seo-gu, Busan (Korea, Republic of); Ma, Sun Young; Jeung, Tae Sig [Department of Radiation Oncology, Kosin University College of Medicine, Seo-gu, Busan (Korea, Republic of); Yi, Byong Yong [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States); Lee, Sang Hoon [Department of Radiation Oncology, Cheil General Hospital and Women's Healthcare Center, Kwandong University College of Medicine, Jung-gu, Seoul (Korea, Republic of); Lee, Suk [Department of Radiation Oncology, College of Medicine, Korea University, Seongbuk-gu, Seoul (Korea, Republic of); Cho, Sam Ju [Department of Radiation Oncology, Eulji University School of Medicine, Eulji General Hospital, Nowon-gu, Seoul (Korea, Republic of); Choi, Jinho [Department of Radiation Oncology, Gachon University of Medicine and Science, Namdong-gu, Incheon (Korea, Republic of)

2012-10-01T23:59:59.000Z

286

Construction quality assurance for Pit 6 landfill closure, Lawrence Livermore National Laboratory, Site 300  

SciTech Connect (OSTI)

Golder Construction Services, Inc. (GCS), under contract to the Regents of the University of California, Lawrence Livermore National Laboratory (LLNL), provided the construction quality assurance (CQA) observation and testing during the construction of the Site 300, Pit 6 landfill closure cover. The cap construction was performed as a CERCLA non-time-critical removal action from June 2 to August 29, 1997. the project site is located 18 miles east of Livermore on Tesla Road and approximately 10 miles southwest of Tracy on Corral Hollow Road in San Joaquin County, California. This report certifies that the LLNL, Site 300, Pit 6, Landfill Closure was constructed in accordance with the construction specifications and design drawings. This report documents construction activities and CQA monitoring and testing for construction of the Pit 6 Landfill Closure. Golder Associates, Inc. of Oakland, California was the design engineering firm responsible for preparation of the drawings and specifications. CQA services were provided by GCS, of Roseville, California, under supervision of a California registered civil Engineer.

NONE

1997-10-30T23:59:59.000Z

287

Quality Assurance of Radiation Therapy Planning Systems: Current Status and Remaining Challenges  

SciTech Connect (OSTI)

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both 'type' tests to be performed in the factory and 'site' tests to be performed in the clinic. The American Association of Physicists Task Group Report 67 described benchmark tests for the validation of dose calculation algorithms. Test data are being produced with the backing of the U.S. National Cancer Institute. However, significant challenges remain. Technology keeps evolving rapidly, thus requiring new quality assurance (QA) procedures. Intensity-modulated radiation therapy with its use of inverse optimization has added a new dimension to QA, because the results are not intuitively obvious. New technologies such as real-time ultrasound guidance for brachytherapy, TomoTherapy, and Cyberknife, require their own specialized RTPSs with unique QA requirements. On-line imaging allows for the generation of dose reconstructions using image warping techniques to determine the daily dose delivered to the patient. With increasing computer speeds, real-time reoptimization of treatment plans will become a reality. Gating technologies will require four-dimensional dose calculations to determine the actual dose delivered to tissue voxels. With these rapidly changing technologies, it is essential that a strong QA culture is invoked in every institution implementing these procedures and that new protocols are developed as a part of the clinical implementation process.

Van Dyk, Jacob [Department of Physics and Engineering, London Regional Cancer Program/London Health Sciences Centre, London, ON (Canada); Departments of Oncology, Medical Biophysics, Diagnostic Imaging and Nuclear Medicine, and Physics and Astronomy, University of Western Ontario, London, ON (Canada)], E-mail: jake.vandyk@lhsc.on.ca

2008-05-01T23:59:59.000Z

288

Quality assurance guidance for laboratory assessment plates in support of EM environmental sampling and analysis activities  

SciTech Connect (OSTI)

This document is one of several guidance documents developed to support the EM (DOE Environmental Restoration and Waste Management) Analytical Services program. Its purpose is to introduce assessment plates that can be used to conduct performance assessments of an organization`s or project`s ability to meet quality goals for analytical laboratory activities. These assessment plates are provided as non-prescriptive guidance to EM-support organizations responsible for collection of environmental data for remediation and waste management programs at DOE facilities. The assessments evaluate objectively all components of the analytical laboratory process to determine their proper selection and use.

Not Available

1994-05-01T23:59:59.000Z

289

Underground Test Area Fiscal Year 2013 Annual Quality Assurance Report Nevada National Security Site, Nevada, Revision 0  

SciTech Connect (OSTI)

This report is required by the Underground Test Area (UGTA) Quality Assurance Plan (QAP) and identifies the UGTA quality assurance (QA) activities for fiscal year (FY) 2013. All UGTA organizations—U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO); Desert Research Institute (DRI); Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); Navarro-Intera, LLC (N-I); National Security Technologies, LLC (NSTec); and the U.S. Geological Survey (USGS)—conducted QA activities in FY 2013. The activities included conducting assessments, identifying findings and completing corrective actions, evaluating laboratory performance, and publishing documents. In addition, integrated UGTA required reading and corrective action tracking was instituted.

Krenzien, Susan; Marutzky, Sam

2014-01-01T23:59:59.000Z

290

Underground Test Area Fiscal Year 2012 Annual Quality Assurance Report Nevada National Security Site, Nevada, Revision 0  

SciTech Connect (OSTI)

This report is mandated by the Underground Test Area (UGTA) Quality Assurance Project Plan (QAPP) and identifies the UGTA quality assurance (QA) activities for fiscal year (FY) 2012. All UGTA organizations—U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO); Desert Research Institute (DRI); Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); Navarro-Intera, LLC (N-I); National Security Technologies, LLC (NSTec); and the U.S. Geological Survey (USGS)—conducted QA activities in FY 2012. The activities included conducting assessments, identifying findings and completing corrective actions, evaluating laboratory performance, revising the QAPP, and publishing documents. In addition, processes and procedures were developed to address deficiencies identified in the FY 2011 QAPP gap analysis.

Farnham, Irene; Marutzky, Sam

2013-01-01T23:59:59.000Z

291

Water Quality Program, Volume 1 (Alabama)  

Broader source: Energy.gov [DOE]

This volume of the water quality program mainly deals with the National Pollutant Discharge Elimination System. National Pollutant Discharge Elimination System" or "(NPDES)" means the national...

292

Water Quality Program, Volume 2 (Alabama)  

Broader source: Energy.gov [DOE]

This volume of the water quality program mainly deals with Technical Standards, Corrective Action Requirements and Financial Responsibility for Owners and Operators of Underground Storage Tanks....

293

SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Project Tracking...  

Office of Environmental Management (EM)

Project Tracking Checklist SOFTWARE QUALITY & SYSTEMS ENGINEERING PROGRAM: Project Tracking Checklist The following checklist is intended to provide system owners, project...

294

Water Quality Trading Program (Ohio)  

Broader source: Energy.gov [DOE]

Water quality trading is a tool for achieving water quality improvements. Under the right circumstances, trading has the potential to yield both environmental and economic benefits, while...

295

Evaluation of methods, instrumentation and materials pertinent to quality assurance filter penetration testing  

SciTech Connect (OSTI)

Every high efficiency aerosol filter used in the Unites States Department of Energy (DOE) facilities is quality assurance (QA) tested at one of the DOE filter test facilities prior to installation. This testing presently includes measurement of filter penetration at rated airflow using a hot DOP aerosol generator, an Owl aerosol size analyzer, and a scattered-light photometer aerosol concentration monitor. Alternative penetration measurement methods for testing size 5 high efficiency aerosol filters which have rated airflow capacities of 1000 cubic feet/min (cfm, approx. 28 m/sup 3//min) are being studied at Los Alamos National Laboratory. These methods are intended to take advantage of commercially available aerosol instrumentation. A penetration test using a polydisperse aerosol produced with a modified Laskin nozzle aerosol generator was found to have promise as an alternative to the present test method. Such a test eliminates the difficulty in producing a monodisperse challenge aerosol, and takes advantage of state-of-the-art aerosol sizing instruments. Aerosol sizing and concentration measuring capabilities of a laser aerosol spectrometer (LAS) were evaluated with respect to the needs of QA filter penetration testing. An aerosol diluter was selected and evaluated for use with the LAS in making filter penetration measurements. Potential alternative test materials were scrutinized with respect to certain toxicological and physical criteria. Certain of these alternative materials were selected for further evaluation. Results of this evaluation and findings cited in the literature indicate that the selected materials could be easily adapted for use with the modified Laskin aerosol generator.

Scripsick, R.C.; Soderholm, S.C.; Tillery, M.I.

1984-01-01T23:59:59.000Z

296

Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy  

SciTech Connect (OSTI)

To develop a quality assurance (QA) of XVI cone beam system (XVIcbs) for its optimal imaging-guided radiotherapy (IGRT) implementation, and to construe prostate tumor margin required for intensity-modulated radiation therapy (IMRT) if IGRT is unavailable. XVIcbs spatial accuracy was explored with a humanoid phantom; isodose conformity to lesion target with a rice phantom housing a soap as target; image resolution with a diagnostic phantom; and exposure validation with a Radcal ion chamber. To optimize XVIcbs, rotation flexmap on coincidency between gantry rotational axis and that of XVI cone beam scan was investigated. Theoretic correlation to image quality of XVIcbs rotational axis stability was elaborately studied. Comprehensive QA of IGRT using XVIcbs has initially been explored and then implemented on our general IMRT treatments, and on special IMRT radiotherapies such as head and neck (H and N), stereotactic radiation therapy (SRT), stereotactic radiosurgery (SRS), and stereotactic body radiotherapy (SBRT). Fifteen examples of prostate setup accounted for 350 IGRT cone beam system were analyzed. IGRT accuracy results were in agreement {+-} 1 mm. Flexmap 0.25 mm met the manufacturer's specification. Films confirmed isodose coincidence with target (soap) via XVIcbs, otherwise not. Superficial doses were measured from 7.2-2.5 cGy for anatomic diameters 15-33 cm, respectively. Image quality was susceptible to rotational stability or patient movement. IGRT using XVIcbs on general IMRT treatments such as prostate, SRT, SRS, and SBRT for setup accuracy were verified; and subsequently coordinate shifts corrections were recorded. The 350 prostate IGRT coordinate shifts modeled to Gaussian distributions show central peaks deviated off the isocenter by 0.6 {+-} 3.0 mm, 0.5 {+-} 4.5 mm in the X(RL)- and Z(SI)-coordinates, respectively; and 2.0 {+-} 3.0 mm in the Y(AP)-coordinate as a result of belly and bladder capacity variations. Sixty-eight percent of confidence was within {+-} 4.5 mm coordinates shifting. IGRT using XVIcbs is critical to IMRT for prostate and H and N, especially SRT, SRS, and SBRT. To optimize this modality of IGRT, a vigilant QA program is indispensable. Prostate IGRT reveals treatment accuracy as subject to coordinates' adjustments; otherwise a 4.5-mm margin is required to allow for full dose coverage of the clinical target volume, notwithstanding toxicity to normal tissues.

Tsai, Jen-San, E-mail: jen-san.tsai@verizon.net [Department of Radiation Oncology, Temple University Hospital, Philadelphia, PA (United States); Micaily, Bizhan; Miyamoto, Curtis [Department of Radiation Oncology, Temple University Hospital, Philadelphia, PA (United States)

2012-10-01T23:59:59.000Z

297

Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System - 1997 Notice of Violation Consent Order  

SciTech Connect (OSTI)

This Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA- 731 Caustic and Acid Storage Tank System is one of two documents that comprise the Sampling and Analysis Plan for the HWMA/RCRA closure certification of the TRA-731 caustic and acid storage tank system at the Idaho National Engineering and Environmental Laboratory. This plan, which provides information about the project description, project organization, and quality assurance and quality control procedures, is to be used in conjunction with the Field Sampling Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System. This Quality Assurance Project Plan specifies the procedures for obtaining the data of known quality required by the closure activities for the TRA-731 caustic and acid storage tank system.

Evans, S.K.

2002-01-31T23:59:59.000Z

298

Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System - 1997 Notice of Violation Consent Order  

SciTech Connect (OSTI)

This Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System is one of two documents that comprise the Sampling and Analysis Plan for the HWMA/RCRA closure certification of the TRA-731 caustic and acid storage tank system at the Idaho National Engineering and Environmental Laboratory. This plan, which provides information about the project description, project organization, and quality assurance and quality control procedures, is to be used in conjunction with the Field Sampling Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System. This Quality Assurance Project Plan specifies the procedures for obtaining the data of known quality required by the closure activities for the TRA-731 caustic and acid storage tank system.

Evans, Susan Kay; Orchard, B. J.

2002-01-01T23:59:59.000Z

299

RELAP5/MOD3 code quality assurance plan for ORNL ANS narrow channel flow and heat transfer correlations  

SciTech Connect (OSTI)

Modifications have been made to REIAP5 to account for flow and heat transfer in narrow channels between fuel plates such as found in the cores of the Advanced Neutron Source (ANS) and High Flux Isotope Reactor (HFIR) reactors. These early models were supplied by Art Ruggles of Oak Ridge National Laboratory (ORNL) and Don Fletcher of the Idaho National Engineering Laboratory (INEL) and were adapted to and implemented into RELAP5 by Rich Riemke, Rex Shumway and Ken Katsma. The purpose of this report is to document the current status of these special models in the standard version of RELAP5/MOD3 and describe the quality assurance procedures.

MIller, C.S.; Shumway, R.W.

1992-11-01T23:59:59.000Z

300

Environmental Restoration Program quality system requirements for the Hanford Site. Revision 2  

SciTech Connect (OSTI)

This document defines the quality system requirements for the US Department of Energy, Richland Operations Office, Environmental Restoration Program at the Hanford Site. The Quality System Requirements (OSR) for the Hanford Site integrates quality assurance requirements from the US Department of Energy Orders, the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), and applicable industry standards into a single source document for the development of quality systems applicable to the Environmental Restoration Program activities. This document, based on fifteen criteria and divided intro three parts, provides user organizations with the flexibility to incorporate only those criteria and parts applicable to their specific scopes of work. The requirements of this document shall be applied to activities that affect quality based on a graded approach that takes into consideration the risk inherent in, as well as the importance of, specific items, services, and activities in terms of meeting ER Program objectives and customer expectations. The individual quality systems developed in accordance with this document are intended to provide an integrated management control system that assures the conduct of ER Program activities in a manner that protects human health and the environment.

Cote, R.F.

1993-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Independent Verification and Validation Of SAPHIRE 8 Software Quality Assurance Plan Project Number: N6423 U.S. Nuclear Regulatory Commission  

SciTech Connect (OSTI)

This report provides an evaluation of the Software Quality Assurance Plan. The Software Quality Assurance Plan is intended to ensure all actions necessary for the software life cycle; verification and validation activities; documentation and deliverables; project management; configuration management, nonconformance reporting and corrective action; and quality assessment and improvement have been planned and a systematic pattern of all actions necessary to provide adequate confidence that a software product conforms to established technical requirements; and to meet the contractual commitments prepared by the sponsor; the Nuclear Regulatory Commission.

Kent Norris

2010-02-01T23:59:59.000Z

302

Some Simple Principles in the Collection of Engineering and Quality Assurance Whether data are to be used to monitor process stability/performance or to guide changes  

E-Print Network [OSTI]

Some Simple Principles in the Collection of Engineering and Quality Assurance Data Whether data. (For example, a blanket "take a 10% sample" rule will sometimes over-sample and sometimes under presentation quality displays. 6. In order to be useful in indicating sources of variation in a data set, care

Vardeman, Stephen B.

303

Software archeology: a case study in software quality assurance and design  

SciTech Connect (OSTI)

Ideally, quality is designed into software, just as quality is designed into hardware. However, when dealing with legacy systems, demonstrating that the software meets required quality standards may be difficult to achieve. As the need to demonstrate the quality of existing software was recognized at Los Alamos National Laboratory (LANL), an effort was initiated to uncover and demonstrate that legacy software met the required quality standards. This effort led to the development of a reverse engineering approach referred to as software archaeology. This paper documents the software archaeology approaches used at LANL to document legacy software systems. A case study for the Robotic Integrated Packaging System (RIPS) software is included.

Macdonald, John M [Los Alamos National Laboratory; Lloyd, Jane A [Los Alamos National Laboratory; Turner, Cameron J [COLORADO SCHOOL OF MINES

2009-01-01T23:59:59.000Z

304

E-Print Network 3.0 - action quality assurance Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

that is developed, implemented... the management process for providing resources.) DOE Order 414.1, Attachment 2, Quality ... Source: Los Alamos National Laboratory, Theoretical...

305

Energy Savings Performance Contracts: Quality Assurance Over the Life of the Contract Webinar Transcript  

Broader source: Energy.gov [DOE]

Kurmit Rockwell:Welcome.  I'm Kurmit Rockwell, the ESPC Program Manager for DOE's Federal Energy Management Program.  In this presentation we will focus on what you need to know after your ESPC...

306

Quality assurance project plan for the Chestnut Ridge Fly Ash Pond Stabilization Project at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee  

SciTech Connect (OSTI)

The Chestnut Ridge Fly Ash Pond Stabilization (CRFAPS) Project will stabilize a 19-m-high (62-ft-high) earthen embankment across Upper McCoy Branch situated along the southern slope of Chestnut Ridge. This task will be accomplished by raising the crest of the embankment, reinforcing the face of the embankment, removing trees from the face and top of the embankment, and repairing the emergency spillway. The primary responsibilities of the team members are: Lockheed Martin Energy Systems, Inc., (Energy Systems) will be responsible for project integration, technical support, Title 3 field support, environmental oversight, and quality assurance (QA) oversight of the project; Foster Wheeler Environmental Corporation (FWENC) will be responsible for design and home office Title 3 support; MK-Ferguson of Oak Ridge Company (MK-F) will be responsible for health and safety, construction, and procurement of construction materials. Each of the team members has a QA program approved by the US Department of Energy (DOE) Oak Ridge Operations. This project-specific QA project plan (QAPP), which is applicable to all project activities, identifies and integrates the specific QA requirements from the participant`s QA programs that are necessary for this project.

NONE

1996-07-01T23:59:59.000Z

307

Evaluation of Quality-Assurance/Quality-Control Data Collected by the U.S. Geological Survey from Wells and Springs between the Southern Boundary of the Idaho National Engineering and Environmental Laboratory and the Hagerman Area, Idaho, 1989 through 1995  

SciTech Connect (OSTI)

The U.S. Geological (USGS) and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, collected and analyzed water samples to monitor the water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area, Idaho. Concurrently, replicate samples and blank samples were collected and analyzed as part of the quality-assurance/quality-control program. Samples were analyzed from inorganic constituents, gross radioactivity and radionuclides, organic constituents, and stable isotopes. To evaluate the precision of field and laboratory methods, analytical results of the water-quality and replicate samples were compared statistically for equivalence on the basis of the precision associated with each result. Statistical comparisons of the data indicated that 95 percent of the results of the replicate pairs were equivalent. Blank-sample analytical results indicated th at the inorganic blank water and volatile organic compound blank water from the USGS National Water Quality Laboratory and the distilled water from the Idaho Department of Water Resources were suitable for blanks; blank water from other sources was not. Equipment-blank analytical results were evaluated to determine if a bias had been introduced and possible sources of bias. Most equipment blanks were analyzed for trace elements and volatile organic compounds; chloroform was found in one equipment blank. Two of the equipment blanks were prepared after collection and analyses of the water-quality samples to determine whether contamination had been introduced during the sampling process. Results of one blank indicated that a hose used to divert water away from pumps and electrical equipment had contaminated the samples with some volatile organic compounds. Results of the other equipment blank, from the apparatus used to filter dissolved organic carbon samples, indicated that the filtering apparatus did not affect water-quality samples.

Williams, L.M.; Bartholomay, R.C.; Campbell, L.J.

1998-10-01T23:59:59.000Z

308

Implementation guide for use with suspect/counterfeit items: Requirements of DOE O 440.1, worker protection management; 10 CFR 830.120; and DOE 5700.6C, quality assurance  

SciTech Connect (OSTI)

Department of Energy (DOE) Order (O) 440.1, Worker Protection Management For DOE Federal and Contractors Employees, [7] sets forth requirements for DOE and its contractors to implement suspect and counterfeit items (S/CI) controls as part of the quality assurance (QA) programs required by 10 Code of Federal Regulations (CFR) 830.120 [8] or DOE 5700.6C, Quality Assurance [9]. DOE G-830.120, Implementation Guide for Use with 10 CFR Part 830.120, Quality Assurance, [10] provides additional guidance on establishing and implementing effective QA processes to control S/CIs. DOE O 232.1, Occurrence Reporting and Processing of Operations, [11] specifies requirements for reporting S/CIs under the DOE Occurrence Reporting and Processing System (ORPS). DOE promulgated the requirements and guidance to control or eliminate the hazards posed by S/CIs, which can lead to unexpected equipment failures and undue risks to the DOE mission, the environment, and personnel. This Guide is a compendium of information contained in the referenced DOE directives and other documents concerning S/CI controls. It incorporates, updates, and supersedes earlier guidance issued in Plan for the Suspect/Counterfeit Products Issue in the Department of Energy, dated October 1993, [4] and in memoranda issued by Defense Programs (DP) [12-16] and other DOE program offices. This guidance was developed to strengthen the procurement process, identify and eliminate S/CIs, and improve the reporting of S/CIs. The information in this Guide, when implemented by DOE and its contractors, will satisfy the S/CI requirements contained in the referenced DOE directives.

NONE

1997-06-01T23:59:59.000Z

309

QUALITY ASSURANCE / QUALITY CONTROL MANUAL FOR THE LOWER CAPE FEAR RIVER PROGRAM  

E-Print Network [OSTI]

Chain of Custody 4 9 Equipment Maintenance and Calibration 10 10 Standard Operating Procedures.1 Sampling Schedule Table 6.2 Station Map Figure 6.1 7 Standard Operating Procedures for Field Sampling 18 8 13 QA/QC Audits 32 14 Reports and Publications 4 Appendix I Standard Operating Procedures for State

Mallin, Michael

310

Safety Software Quality Assurance Functions, Responsibilities, and Authorities for Nuclear Facilities and Activities  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To assign roles and responsibilities for improving the quality of safety software. DOE N 411.2 (archived) extends this Notice until 01/31/2005. DOE N 411.3 extends this Notice until 1/31/06. Canceled by DOE O 414.1C. does not cancel other directives.

2003-08-27T23:59:59.000Z

311

Sasquatch Semantical Approach of Assuring high Data Quality by Applying Data Mining Techniques  

E-Print Network [OSTI]

be to delete those data, or to correct them by a domain expert or by the data quality management system itself in enterprises' data management systems. It utilizes two main ideas for its goal: On the one hand the given data schemas of one or more data management systems are mapped to the concepts and properties of an either

Appelrath, Hans-Jürgen

312

Morphological Analysis of Zirconium Nuclear Fuel Retaining Rods Braided with SiC: Quality Assurance and Defect Identification  

SciTech Connect (OSTI)

In the after-Fukushima world, the stability of materials under extreme conditions is an important issue for the safety of nuclear reactors. Among the methods explored currently to improve zircaloys’ thermal stability in off-normal conditions, using a protective coat of the SiC filaments is considered because silicon carbide is well known for its remarkable chemical inertness at high temperatures. A typical SiC fiber contains ~50,000 individual filaments of 5 – 10 µm in diameter. In this paper, an effort was made to develop and apply mathematical morphology to the process of automatic defect identification in Zircaloy-4 rods braided with the protective layer of the silicon carbide filament. However, the issues of the braiding quality have to be addressed to ensure its full protective potential. We present the original mathematical morphology algorithms that allow solving this problem of quality assurance successfully. In nuclear industry, such algorithms are used for the first time, and could be easily generalized to the case of automated continuous monitoring for defect identification in the future.

Michael V Glazoff; Robert Hiromoto; Akira Tokuhiro

2014-08-01T23:59:59.000Z

313

Expert systems: A new approach to radon mitigation training and quality assurance  

SciTech Connect (OSTI)

Training radon mitigators and ensuring that they provide high-quality work on the scale necessary to reduce radon to acceptable levels in the large number of homes and schools requiring some mitigation is a challenging problem. The US Environmental Protection Agency and several states have made commendable efforts to train mitigators and ensure that they provide quality services to the public. Expert systems could be used to extend and improve the effectiveness of these efforts. The purpose of this paper is to introduce the radon community to this promising new technology. The paper includes a description of a prototype system developed by Pacific Northwest Laboratory that illustrates several of the capabilities that expert systems can provide, a brief explanation of how the prototype works, and a discussion of the potential roles and benefits of fully-developed expert systems for radon mitigation. 4 refs., 3 figs.

Brambley, M.R.; Hanlon, R.L.; Parker, G.B.

1990-07-01T23:59:59.000Z

314

Implementation of a Geographic Information System for municipal water quality assurance  

E-Print Network [OSTI]

of Northwest Agencies with ARC/INFO Projects. . . . . . 64 I: INTRODUCTION The difficult task of watershed management involves maximizing the quality and quantity of wata for domestic, industrial, and transport uses while maintaining conditions favorable... to its ability to work with the AutoCAD drawings, the TPUW forester chose to have the Environmental Systems Research Institute's (ESRI) ARC/INFO coverages from WADNR converted to ArcCAD format. ArcCAD is a computer-aided design (CAD) system which...

Murphy, Eileen Marie

1996-01-01T23:59:59.000Z

315

Order Module--DOE O 414.1D, QUALITY ASSURANCE | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProvedDecemberInitiativesNationalNuclear Safety Officethe ChiefServices14.1D, QUALITY

316

DOE Order Self Study Modules - DOE O 414.1D Quality Assurance  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems EngineeringDepartmentSmartDepartment of1WIPP |Save05.1BIdaho |in Alaska14.1D QUALITY

317

The status of ceramic turbine component fabrication and quality assurance relevant to automotive turbine needs  

SciTech Connect (OSTI)

This report documents a study funded by the U.S. Department of Energy (DOE) Office of Transportation Technologies (OTT) with guidance from the Ceramics Division of the United States Automotive Materials Partnership (USAMP). DOE and the automotive companies have funded extensive development of ceramic materials for automotive gas turbine components, the most recent effort being under the Partnership for a New Generation of Vehicles (PNGV) program.

Richerson, D.W.

2000-02-01T23:59:59.000Z

318

Dosimetry quality assurance in Martin Marietta Energy Systems' centralized external dosimetry system  

SciTech Connect (OSTI)

External dosimetry needs at the four Martin Marietta Energy Systems facilities are served by Energy Systems Centralized External Dosimetry System (CEDS). The CEDS is a four plant program with four dosimeter distribution centers and two dosimeter processing centers. Each plant has its own distribution center, while processing centers are located at ORNL and the Y-12 Plant. The program has been granted accreditation by the Department of Energy Laboratory Accreditation Program (DOELAP). The CEDS is a TLD based system which is responsible for whole-body beta-gamma, neutron, and extremity monitoring. Beta-gamma monitoring is performed using the Harshaw/Solon Technologies model 8805 dosimeter. Effective October 1, 1992 the standard silver mylar has been replaced with an Avery mylar foil blackened on the underside with ink. This was done in an effort to reduce the number of light induced suspect readings. At this time we have little operational experience with the new blackened mylars-The CEDS neutron dosimeter is the Harshaw model 8806B. This card/holder configuration contains two TLD-600/TLD-700 chip pairs; one pair is located beneath a cadmium filter and one pair is located beneath a plastic filter. In routine personnel monitoring the CEDS neutron dosimeter is always paired with a CEDS beta-gamma dosimeter.The CEDS extremity dosimeter is composed of a Harshaw thin TLD-700 dosiclip placed inside a Teledyne RB-4 finger sachet. The finger sachet provides approximately 7 mg/cm[sup 2] filtration over the chip. A teflon ring surrounds the dosiclip to help prevent tearing of the vinyl sachet.

Souleyrette, M.L.

1992-10-23T23:59:59.000Z

319

Ava Holland Joins DOE Carlsbad Field Office As Quality Assurance Manager  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAboutScience Program Cumulus Humilis, 2014AutomatedAutomotiveAva Holland

320

NRC (Nuclear Regulatory Commission) perspective of software QA (quality assurance) in the nuclear history  

SciTech Connect (OSTI)

Computer technology has been a part of the nuclear industry since its inception. However, it is only recently that computers have been integrated into reactor operations. During the early history of commercial nuclear power in the United States, the US Nuclear Regulatory Commission (NRC) discouraged the use of digital computers for real-time control and monitoring of nuclear power plant operation. At the time, this position was justified since software engineering was in its infancy, and horror stories on computer crashes were plentiful. Since the advent of microprocessors and inexpensive computer memories, significant advances have been made in fault-tolerant computer architecture that have resulted in highly reliable, durable computer systems. The NRC's requirement for safety parameter display system (SPDS) stemmed form the results of studies and investigations conducted on the Three Mile Island Unit 2 (TMI-2) accident. An NRC contractor has prepared a handbook of software QA techniques applicable to the nuclear industry, published as NUREG/CR-4640 in August 1987. Currently, the NRC is considering development of an inspection program covering software QA. Future efforts may address verification and validation as applied to expert systems and artificial intelligence programs.

Weiss, S.H.

1988-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Final construction quality assurance report for the Y-12 Industrial Landfill V, Area 2, Oak Ridge, Tennessee  

SciTech Connect (OSTI)

Lockheed Martin Energy Systems (LMES) has finished construction of Area 2 of the Y-12 Plant Industrial Landfill (ILF-V), classified as a Class 2 Landfill. This final Construction Quality Assurance (CQA) Report provides documentation that Area 2 was constructed in substantial compliance with the Tennessee Department of Environment and Conservation (TDEC) approved design, as indicated and specified in the permit drawings, approved changes, and specifications. This report applies specifically to the Area 2 excavation, compacted clay soil liner, geomembrane liner, granular leachate collection layer, protective soil cover, and the leachate collection system. An ``As-Built`` survey was performed and is included. The drawings provide horizontal and vertical information for Area 2, the anchor trench, the leachate collection pipe, the temporary access road, and cross-sections of Area 2. This report provides documentation of the following items: the excavation activities of Area 2; the maximum recompacted coefficient of hydraulic conductivity or permeability of the soil is less than 1 {times} 10{sup {minus}7} centimeters per second (cm/sec); the total thickness of the compacted clay soil liner equals a minimum of 2 feet; a 40 mil impermeable geomembrane (polypropylene) flexible membrane liner (FML) and 16 oz. geotextile fabric was placed in direct contact with the compacted clay soil liner; a 12 inch granular leachate collection layer was installed and covered with a 8 oz. geotextile separation fabric; the installation of the leachate collection piping; and the two foot protective clay soil cover.

Bessom, W.H. [Lockheed Martin Energy Systems, Inc., Oak Ridge, TN (United States)

1996-11-01T23:59:59.000Z

322

Reliable detection of fluence anomalies in EPID-based IMRT pretreatment quality assurance using pixel intensity deviations  

SciTech Connect (OSTI)

Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of {>=}5% in {approx}1 mm{sup 2} areas and {>=}2% in {approx}20 mm{sup 2} areas. Conclusions: The ability to detect small dose differences ({<=}2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified.

Gordon, J. J.; Gardner, J. K.; Wang, S.; Siebers, J. V. [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan 48202 (United States); Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Department of Radiation Oncology, Weill Cornell Medical College, New York, New York 10095 (United States); Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States)

2012-08-15T23:59:59.000Z

323

Microbiological, Geochemical and Hydrologic Processes Controlling Uranium Mobility: An Integrated Field-Scale Subsurface Research Challenge Site at Rifle, Colorado, Quality Assurance Project Plan  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) is cleaning up and/or monitoring large, dilute plumes contaminated by metals, such as uranium and chromium, whose mobility and solubility change with redox status. Field-scale experiments with acetate as the electron donor have stimulated metal-reducing bacteria to effectively remove uranium [U(VI)] from groundwater at the Uranium Mill Tailings Site in Rifle, Colorado. The Pacific Northwest National Laboratory and a multidisciplinary team of national laboratory and academic collaborators has embarked on a research proposed for the Rifle site, the object of which is to gain a comprehensive and mechanistic understanding of the microbial factors and associated geochemistry controlling uranium mobility so that DOE can confidently remediate uranium plumes as well as support stewardship of uranium-contaminated sites. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by the Rifle Integrated Field-Scale Subsurface Research Challenge Project.

Fix, N. J.

2008-01-07T23:59:59.000Z

324

CRMAP Agenda at a Glance March 10, 2014 Combined Regional Measurement Assurance Program (CRMAP) 2014 Agenda  

E-Print Network [OSTI]

am to 12 N *Mass Uncertainties (NISTIR 5672, 6969 2014 Updates) @Quality Management System Reviews ^Proficiency Testing Statistics (ISO 13528) &Statistics ­ Top Q&A #Quality Management Topics %ProLab Plus ­ Coordinator and Analyst Training $Water Purification Systems Breakouts

325

Standard Review Plan for Environmental Restoration Program Quality Management Plans. Revision 2  

SciTech Connect (OSTI)

The Department of Energy, Richland Operations Office (RL) Manual Environmental Restoration Program Quality System Requirements (QSR) for the Hanford Site, defines all quality requirements governing Hanford Environmental Restoration (ER) Program activities. The QSR requires that ER Program participants develop Quality Management Plans (QMPs) that describe how the QSR requirements will be implemented for their assigned scopes of work. This standard review plan (SRP) describes the ER program participant responsibilities for submittal of QMPs to the RL Environmental Restoration Division for review and the RL methodology for performing the reviews of participant QMPS. The SRP serves the following functions: acts as a guide in the development or revision of QMPs to assure that the content is complete and adequate; acts as a checklist to be used by the RL staff in their review of participant QMPs; acts as an index or matrix between the requirements of the QSR and implementing methodologies described in the QMPs; decreases the time and subjectivity of document reviews; and provides a formal, documented method for describing exceptions, modifications, or waivers to established ER Program quality requirements.

Not Available

1993-12-01T23:59:59.000Z

326

Specified assurance level sampling procedure  

SciTech Connect (OSTI)

In the nuclear industry design specifications for certain quality characteristics require that the final product be inspected by a sampling plan which can demonstrate product conformance to stated assurance levels. The Specified Assurance Level (SAL) Sampling Procedure has been developed to permit the direct selection of attribute sampling plans which can meet commonly used assurance levels. The SAL procedure contains sampling plans which yield the minimum sample size at stated assurance levels. The SAL procedure also provides sampling plans with acceptance numbers ranging from 0 to 10, thus, making available to the user a wide choice of plans all designed to comply with a stated assurance level.

Willner, O.

1980-11-01T23:59:59.000Z

327

Quality and ES H Self-Appraisal Program at the Center for Applied Physics, Engineering and Testing  

SciTech Connect (OSTI)

This report describes the Quality and ES H Self-Appraisal Program at the Center for Applied Physics, Engineering and Testing, 9300 and explains how the program promotes good Conduct of Operations'' throughout the center and helps line managers improve efficiency and maintain a safe work environment. The program provides a means to identify and remove hazards and to ensure workers are following correct and safe procedures; but, most importantly, 9300's Self-Appraisal program uses DOE's Conduct of Operations'' and Quality Assurance'' guidelines to evaluate the manager's policies and decisions. The idea is to draw attention to areas for improvement in ES H while focusing on how well the organization's processes and programs are doing. A copy of the Administrative Procedure which establishes and defines the program, as well as samples of a Self-Appraisal Report and a Manager's Response to the Self-Appraisal Report are provided as appendixes.

Sullivan, J.J.; Zawadzkas, G.A.

1993-05-01T23:59:59.000Z

328

Quality and ES&H Self-Appraisal Program at the Center for Applied Physics, Engineering and Testing  

SciTech Connect (OSTI)

This report describes the Quality and ES&H Self-Appraisal Program at the Center for Applied Physics, Engineering and Testing, 9300 and explains how the program promotes good ``Conduct of Operations`` throughout the center and helps line managers improve efficiency and maintain a safe work environment. The program provides a means to identify and remove hazards and to ensure workers are following correct and safe procedures; but, most importantly, 9300`s Self-Appraisal program uses DOE`s ``Conduct of Operations`` and ``Quality Assurance`` guidelines to evaluate the manager`s policies and decisions. The idea is to draw attention to areas for improvement in ES&H while focusing on how well the organization`s processes and programs are doing. A copy of the Administrative Procedure which establishes and defines the program, as well as samples of a Self-Appraisal Report and a Manager`s Response to the Self-Appraisal Report are provided as appendixes.

Sullivan, J.J.; Zawadzkas, G.A.

1993-05-01T23:59:59.000Z

329

Quality Assurance REFERENCE GUIDE  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalancedDepartment ofColumbus HTS1, 2008 CompanyQTRQualityNOT MEASUREMENT

330

E-Print Network 3.0 - assurance program fcap Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

to checking satisfiability... and Programming 33rd International Colloquium, ICALP 2006, Venice : Italie (2006)" DOI : 10.100711787006 12 Source: Ecole Polytechnique, Centre de...

331

Use of treatment log files in spot scanning proton therapy as part of patient-specific quality assurance  

SciTech Connect (OSTI)

Purpose: The purpose of this work was to assess the monitor unit (MU) values and position accuracy of spot scanning proton beams as recorded by the daily treatment logs of the treatment control system, and furthermore establish the feasibility of using the delivered spot positions and MU values to calculate and evaluate delivered doses to patients. Methods: To validate the accuracy of the recorded spot positions, the authors generated and executed a test treatment plan containing nine spot positions, to which the authors delivered ten MU each. The spot positions were measured with radiographic films and Matrixx 2D ion-chambers array placed at the isocenter plane and compared for displacements from the planned and recorded positions. Treatment logs for 14 patients were then used to determine the spot MU values and position accuracy of the scanning proton beam delivery system. Univariate analysis was used to detect any systematic error or large variation between patients, treatment dates, proton energies, gantry angles, and planned spot positions. The recorded patient spot positions and MU values were then used to replace the spot positions and MU values in the plan, and the treatment planning system was used to calculate the delivered doses to patients. The results were compared with the treatment plan. Results: Within a treatment session, spot positions were reproducible within {+-}0.2 mm. The spot positions measured by film agreed with the planned positions within {+-}1 mm and with the recorded positions within {+-}0.5 mm. The maximum day-to-day variation for any given spot position was within {+-}1 mm. For all 14 patients, with {approx}1 500 000 spots recorded, the total MU accuracy was within 0.1% of the planned MU values, the mean (x, y) spot displacement from the planned value was (-0.03 mm, -0.01 mm), the maximum (x, y) displacement was (1.68 mm, 2.27 mm), and the (x, y) standard deviation was (0.26 mm, 0.42 mm). The maximum dose difference between calculated dose to the patient based on the plan and recorded data was within 2%. Conclusions: The authors have shown that the treatment log file in a spot scanning proton beam delivery system is precise enough to serve as a quality assurance tool to monitor variation in spot position and MU value, as well as the delivered dose uncertainty from the treatment delivery system. The analysis tool developed here could be useful for assessing spot position uncertainty and thus dose uncertainty for any patient receiving spot scanning proton beam therapy.

Li Heng; Sahoo, Narayan; Poenisch, Falk; Suzuki, Kazumichi; Li Yupeng; Li Xiaoqiang; Zhang Xiaodong; Gillin, Michael T.; Zhu, X. Ronald [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Lee, Andrew K. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

2013-02-15T23:59:59.000Z

332

E-Print Network 3.0 - assurance program pcap Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

et al. (2003) PCAP: a whole-genome assembly program... ), PCAP (Huang et al., 2003) and Atlas (Havlak et al., 2004)), in some cases after running the assemblers Source: Shapiro,...

333

Performance Assurance for Multi-Year Contracts Under the Utility Incentive Program  

SciTech Connect (OSTI)

This 4-page fact sheet provides guidance for federal energy and facility managers on participation in utility programs for the management of electricity demand, and energy and water conservation.

Not Available

2007-08-01T23:59:59.000Z

334

Program Academic Quality Plan Department of Construction Management  

E-Print Network [OSTI]

Program Academic Quality Plan Department of Construction Management Bowling Green State University://www.bgsu.edu/colleges/technology/undergraduate/cmt/index.html Integral in this effort is our Program Academic Quality Plan. I. Bowling Green State University Mission Bowling Green State University provides educational experiences inside and outside the classroom

Moore, Paul A.

335

Environmental sensor networks and continuous data quality assurance to manage salinity within a highly regulated river basin  

E-Print Network [OSTI]

and Drainage System for Drainage Water Quality Management,quality management using a novel software tool, Aquarius. Commercial turn-key monitoring systems

Quinn, N.W.T.

2010-01-01T23:59:59.000Z

336

Special Report on Review of "The Department of Energy's Quality Assurance Process for Prime Recipients' Reporting for the American Recovery and Reinvestment Act"  

SciTech Connect (OSTI)

The American Recovery and Reinvestment Act of 2009 (Recovery Act) was established to jumpstart the U.S. economy, create or save millions of jobs, spur technological advances in health and science, and invest in the Nation's energy future. The Department of Energy (Department) will receive an unprecedented $37 billion in Recovery Act funding to support a variety of science, energy, and environmental initiatives. The majority of the funding received by the Department will be allocated to various recipients through grants, cooperative agreements, contracts, and other financial instruments. To ensure transparency and accountability, the Office of Management and Budget (OMB) requires that recipients report on their receipt and use of Recovery Act funds on a quarterly basis to FederalReporting.gov. OMB also specifies that Federal agencies should develop and implement formal procedures to help ensure the quality of recipient reported information. Data that must be reported by recipients includes total funding received; funds expended or obligated; projects or activities for which funds were obligated or expended; and the number of jobs created and/or retained. OMB requires that Federal agencies perform limited data quality reviews of recipient data to identify material omissions and/or significant reporting errors and notify the recipients of the need to make appropriate and timely changes to erroneous reports. As part of a larger audit of recipient Recovery Act reporting and performance measurement and in support of a Government-wide review sponsored by the Recovery Accountability and Transparency Board, we completed an interim review to determine whether the Department had established a process to ensure the quality and accuracy of recipient reports. Our review revealed that the Department had developed a quality assurance process to facilitate the quarterly reviews of recipient data. The process included procedures to compare existing information from the Department's financial information systems with that reported to FederalReporting.gov by recipients. In addition, plans were in place to notify recipients of anomalies and/or errors exposed by the quality assurance process. While the Department has made a good deal of progress in this area, we did, however, identify several issues which could, if not addressed, impact the effectiveness of the quality assurance process.

None

2009-10-01T23:59:59.000Z

337

Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method  

SciTech Connect (OSTI)

Purpose: Pretreatment patient plan verification with gamma index (GI) metric analysis is standard procedure for intensity modulated radiation therapy (IMRT) treatment. The aim of this paper is to evaluate the variability of the local and global gamma index obtained during standard pretreatment quality assurance (QA) measurements for plans performed with Tomotherapy unit. The QA measurements were performed with a 3D diode array, using variable passing criteria: 3%/3 mm, 2%/2 mm, 1%/1 mm, each with both local and global normalization.Methods: The authors analyzed the pretreatment QA results for 73 verifications; 37 were prostate cancer plans, 16 were head and neck plans, and 20 were other clinical sites. All plans were treated using the Tomotherapy Hi-Art System. Pretreatment QA plans were performed with the commercially available 3D diode array ArcCHECK™. This device has 1386 diodes arranged in a helical geometry spaced 1 cm apart. The dose measurements were acquired on the ArcCHECK™ and then compared with the calculated dose using the standard gamma analysis method. The gamma passing rate (%GP), defined as the percentage of points satisfying the condition GI < 1, was calculated for different criteria (3%/3 mm, 2%/2 mm, 1%/1 mm) and for both global and local normalization. In the case of local normalization method, the authors set three dose difference threshold (DDT) values of 2, 3, and 5 cGy. Dose difference threshold is defined as the minimum absolute dose error considered in the analysis when using local normalization. Low-dose thresholds (TH) of 5% and 10% were also applied and analyzed.Results: Performing a paired-t-test, the authors determined that the gamma passing rate is independent of the threshold values for all of the adopted criteria (5%TH vs 10%TH, p > 0.1). Our findings showed that mean %GPs for local (or global) normalization for the entire study group were 93% (98%), 84% (92%), and 66% (61%) for 3%/3 mm, 2%/2 mm, and 1%/1 mm criteria, respectively. DDT was equal to 2 cGy for the local normalization analysis cases. The authors observed great variability in the resulting %GP. With 3%/3 mm gamma criteria, the overall passing rate with local normalization was 4.6% less on the average than with global one, as expected. The wide difference between %GP calculated with global or local approach is also confirmed by an unpaired t-test statistical analysis.Conclusions: The variability of %GP obtained confirmed the necessity to establish defined agreement criteria that could be universal and comparable between institutions. In particular, while the gamma passing rate does not depend on the choice of threshold, the choice of DDT strongly influences the gamma passing rate for local calculations. The difference between global and local %GP was statistically significant for prostate and other treatment sites when DDT was changed from 2 to 3 cGy.

Bresciani, Sara; Di Dia, Amalia; Maggio, Angelo; Cutaia, Claudia; Miranti, Anna; Infusino, Erminia; Stasi, Michele [Medical Physics Division, Institute for Cancer Research and Treatment (IRCCS), 10060 Candiolo (Italy)] [Medical Physics Division, Institute for Cancer Research and Treatment (IRCCS), 10060 Candiolo (Italy)

2013-12-15T23:59:59.000Z

338

Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy  

SciTech Connect (OSTI)

Purpose: In this study, the authors are evaluating a new, commercially available 2D array that offers 3D dose reconstruction for patient specific intensity modulated radiation therapy quality assurance (IMRT QA).Methods: The OCTAVIUS 4D system and its accompanying software (VERISOFT) by PTW were evaluated for the accuracy of the dose reconstruction for patient specific pretreatment IMRT QA. OCTAVIUS 4D measures the dose plane at the linac isocenter as the phantom rotates synchronously with the gantry, maintaining perpendicularity with the beam, by means of an inclinometer and a motor. The measurements collected during a volumetric modulated arc therapy delivery (VMAT) are reconstructed into a 3D dose volume. The VERISOFT application is used to perform the analysis, by comparing the reconstructed dose against the 3D dose matrix from the treatment planning system (TPS) that is computed for the same geometry and beam arrangement as that of the measurement. In this study, the authors evaluated the 3D dose reconstruction algorithm of this new system using a series of tests. Using the Octavius 4D phantom as the patient, dose distributions for various field sizes, beam orientations, shapes, and combination of fields were calculated using the Pinnacle3, TPS, and the respective DICOMRT dose was exported to the VERISOFT analysis software. Measurements were obtained by delivering the test treatment plans and comparisons were made based on gamma index, dose profiles, and isodose distribution analysis. In addition, output factors were measured and the dose linearity of the array was assessed. Those measurements were compared against measurements in water using a single, calibrated ionization chamber as well as calculations from Pinnacle for the same delivery geometries.Results: The number of voxels that met the 3%/3 mm criteria for the volumetric 3D gamma index analysis ranged from 92.3% to 98.9% for all the patient plans that the authors evaluated. 2D gamma analysis in the axial, sagittal, and coronal planes produced similar results to those in the 3D gamma analysis. The new detector system does not require an angular dependence correction because it rotates in synchrony with the gantry and the detector array maintains a constant SAD while always perpendicular to the beam axis. Output factors were within 2% when compared to ionization chamber measurements and Pinnacle calculations. Similar agreement was observed when testing the MU linearity (for MU values above 2) as well as dose rate effect.Conclusions: The OCTAVIUS 4D system has some unique characteristics that can potentially improve the patient specific pretreatment IMRT QA data collection and analysis. The ability of the software to reconstruct from the measurements the true 3D dose distribution in the phantom, provides a unique perspective for the medical physicist that evaluates a patient's QA plan.

Stathakis, Sotirios; Myers, Pamela; Esquivel, Carlos; Mavroidis, Panayiotis; Papanikolaou, Nikos [Department of Radiation Oncology, University of Texas Health Science Center at San Antonio, San Antonio, Texas 78229 (United States)

2013-07-15T23:59:59.000Z

339

An overview of the comprehensive proton therapy machine quality assurance procedures implemented at The University of Texas M. D. Anderson Cancer Center Proton Therapy Center-Houston  

SciTech Connect (OSTI)

The number of proton and carbon ion therapy centers is increasing; however, since the publication of the International Commission on Radiation Units and Measurements report, there has been no dedicated report dealing with proton therapy quality assurance. The purpose of this article is to describe the quality assurance procedures performed on the passively scattered proton therapy beams at The University of Texas M. D. Anderson Cancer Center Proton Therapy Center in Houston. The majorities of these procedures are either adopted from procedures outlined in the American Association of Physicists in Medical Task Group (TG) 40 report or are a modified version of the TG 40 procedures. In addition, new procedures, which were designed specifically to be applicable to the synchrotron at the author's center, have been implemented. The authors' procedures were developed and customized to ensure patient safety and accurate operation of synchrotron to within explicit limits. This article describes these procedures and can be used by others as a guideline for developing QA procedures based on particle accelerator specific parameters and local regulations pertinent to any new facility.

Arjomandy, Bijan; Sahoo, Narayan; Zhu, X. Ronald; Zullo, John R.; Wu, Richard Y.; Zhu Mingping; Ding Xiaoning; Martin, Craig; Ciangaru, George; Gillin, Michael T. [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1840 Old Spanish Trail, Houston, Texas 77025 (United States)

2009-06-15T23:59:59.000Z

340

Study of quality assurance regulations for linear accelerators in Korea: A comparison study between the current status in Korea and the international guidelines  

E-Print Network [OSTI]

Quality assurance (QA) for medical linear accelerators is indispensable for appropriate cancer treatment. Some international organizations and western advanced countries provide QA guidelines for linear accelerators. Currently, QA regulations for linear accelerators in Korean hospitals specify a system in which each hospital stipulates its independent hospital-based protocols for QA procedures (HP_QAPs) and conducts QA based on these HP_QAPs while regulatory authorities verify whether items under these HP_QAPs have been performed. However, because this regulatory method cannot guarantee the quality of universal treatment, and QA items with tolerance criteria are different in many hospitals, the presentation of standardized QA items and tolerance criteria is essential. In this study, QA items in HP_QAPs from various hospitals and those presented by international organizations. Concordance rates between QA items for linear accelerators that were presented by the aforementioned organizations and those currently ...

Lee, Hyunho; Jo, Yunhui; Yoon, Myonggeun

2015-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Quality Planning Handbook VERSION 1.0 November 22, 1999, 1998  

E-Print Network [OSTI]

Report DQOs Data Quality Objectives GIS Geographic Information System MSR Management Systems Review Performance Evaluation QA Quality Assurance QC Quality Control QSMP Quality Systems Management Plan PQMP Program Quality Management Plans QIWP Quality Integrated Work Plan QSSC Quality Systems Science Center R

342

EM Quality Assurance Program (EM-QA-001 Revision 0) | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: TopEnergy DOEDealingVehicle1:EnergyDecember 10, 2014 DOEEM-QA-001 Rev.

343

EM Quality Assurance Program (EM-QA-001 Revision 1) | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProvedDecember 2005Department ofDOEDisabilityContractors

344

Audit of the DOE's Commercial Laboratory Quality Assurance Evaluation Program, IG-0374  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3--Logistical5/08 Attendance List1-02Evaluation Report TheU.S.

345

Enforcement Guidance Supplement 99-01: Enforcement of 10 CFR Part 830.120 (Quality Assurance Rule) for Facilities below Hazard Category III  

Broader source: Energy.gov [DOE]

Section 1.3 of the Operational Procedures for Enforcement, published in June 1998, provides the opportunity for the Office of Enforcement and Investigation (EH Enforcement) periodically to issue clarifying guidance regarding the processes used in its enforcement activities. During the past 18 months, EH Enforcement has identified a number of examples in which both DOE and contractor organizations have incorrectly exempted activities from applicability of the DOE Quality Assurance Rule 10 CFR 830.120 (QA Rule). The contractors excluded these activities on the basis that the QA Rule did not apply if the activity was classified as less than a Hazard Category III under DOE Standard 1027-92 (Hazard Categorization and Accident Analysis Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports). Standard 1027 provides guidance for determining whether a facility, activity or area requires a Safety Analysis Report but it does not provide a basis for exclusion from the provisions of the QA Rule.

346

Enforcement Guidance Supplement 99-01:Enforcement of 10 CFR Part 830.120 (Quality Assurance Rule)for Facilities Below Hazard Category III  

Broader source: Energy.gov [DOE]

Section 1.3 of the Operational Procedures for Enforcement, published in June 1998, provides the opportunity for the Office of Enforcement and Investigation (EH Enforcement) periodically to issue clarifying guidance regarding the processes used in its enforcement activities. During the past 18 months, EH Enforcement has identified a number of examples in which both DOE and contractor organizations have incorrectly exempted activities fromapplicability of the DOE Quality Assurance Rule 10 CFR 830.120 (QA Rule). The contractors excluded these activities on the basis that the QA Rule did not apply if the activity was classified as less than a Hazard Category III under DOE Standard 1027-92 (Hazard Categorization and Accident Analysis Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports). Standard 1027 provides guidance for determining whether a facility, activity or area requires a Safety Analysis Report but it does not provide a basis for exclusion from the provisions of the QA Rule.

347

Petronas Gas Bhd experiences in accreditation of ISO 9002 quality assurance standard for its pipeline operations division in Malaysia  

SciTech Connect (OSTI)

Some companies seek ISO 9000 registration for competitive reasons or because customers require it. Petronas Gas Bhd, pipeline division company TOD or Transmission Operations Division, seek ISO 9000 registrations purely for the benefits since the management believes that a well designed and well implemented quality system has a process which tends to be lean, sensitive to customers needs, highly reactive and efficient. This paper informs how TOD sets out to put ISO 9002 international quality system to work in its operations. A Quality Steering Council was formed in Feb. 1994 and the HSE and Quality Management Manager was appointed as management representative. The current working system was first assessed. Next, an implementation plan was prepared. Training was provided and the quality manual prepared followed by all the necessary work procedures and instructions. Finally there was trial implementation and actual live implementation. In January 1995 TOD ISO 9002 registration was approved.

Mohamed, M.A.H. [Petronas Gas Bhd, Johor (Malaysia)

1996-12-31T23:59:59.000Z

348

TEAMS: Indoor Air Quality (IAR) Program  

E-Print Network [OSTI]

in place since April of 2002. Recognizing the need to expand the program in depth and breadth, we designed TEAMS. We were able to do this by assistance from Mike Miller and the EPA, who gave the District six “Tools for Schools” test kits (TfS Kit...

Melton, V.

349

Quality New Mexico recognizes Community Programs Office  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - SeptemberMicroneedlesAdvancedJanuaryNETL-2010/????Quality Management

350

Quality Assurance Management System Guide for Use with 10 CFR 830.120 and DOE O 414.1  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

DOE Elements and DOE contractors should consult this Guide in order to develop and implement effective management systems that are consistent with the Department's quality expectations and that support the Safety Management System Policy, DOE P 450.4. Canceled by DOE G 414.1-2A. Does not cancel other directives.

1999-06-17T23:59:59.000Z

351

Environmental sensor networks and continuous data quality assurance to manage salinity within a highly regulated river basin  

SciTech Connect (OSTI)

This paper describes a new approach to environmental decision support for salinity management in the San Joaquin Basin of California that focuses on web-based data sharing using YSI Econet technology and continuous data quality management using a novel software tool, Aquarius.

Quinn, N.W.T.; Ortega, R.; Holm, L.

2010-01-05T23:59:59.000Z

352

Protocol for EM Review/Field Self-Assessment of Site Specific Quality Assurance Programs/Quality Implementation Plans  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems Engineering Research and Development (PSEEnergyProjectProjectsDiffusion

353

E-Print Network 3.0 - airworthiness assurance validation Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

In line with the requirement in Joint Aviation... audit scheme as part of its quality assurance programme. Remarkably though, in spite of this safety... safety assurance programme...

354

Improving spot-scanning proton therapy patient specific quality assurance with HPlusQA, a second-check dose calculation engine  

SciTech Connect (OSTI)

Purpose: The purpose of this study was to validate the use of HPlusQA, spot-scanning proton therapy (SSPT) dose calculation software developed at The University of Texas MD Anderson Cancer Center, as second-check dose calculation software for patient-specific quality assurance (PSQA). The authors also showed how HPlusQA can be used within the current PSQA framework.Methods: The authors compared the dose calculations of HPlusQA and the Eclipse treatment planning system with 106 planar dose measurements made as part of PSQA. To determine the relative performance and the degree of correlation between HPlusQA and Eclipse, the authors compared calculated with measured point doses. Then, to determine how well HPlusQA can predict when the comparisons between Eclipse calculations and the measured dose will exceed tolerance levels, the authors compared gamma index scores for HPlusQA versus Eclipse with those of measured doses versus Eclipse. The authors introduce the ??? transformation as a way to more easily compare gamma scores.Results: The authors compared measured and calculated dose planes using the relative depth, z/R × 100%, where z is the depth of the measurement and R is the proton beam range. For relative depths than less than 80%, both Eclipse and HPlusQA calculations were within 2 cGy of dose measurements on average. When the relative depth was greater than 80%, the agreement between the calculations and measurements fell to 4 cGy. For relative depths less than 10%, the Eclipse and HPlusQA dose discrepancies showed a negative correlation, ?0.21. Otherwise, the correlation between the dose discrepancies was positive and as large as 0.6. For the dose planes in this study, HPlusQA correctly predicted when Eclipse had and had not calculated the dose to within tolerance 92% and 79% of the time, respectively. In 4 of 106 cases, HPlusQA failed to predict when the comparison between measurement and Eclipse's calculation had exceeded the tolerance levels of 3% for dose and 3 mm for distance-to-agreement.Conclusions: The authors found HPlusQA to be reasonably effective (79%± 10%) in determining when the comparison between measured dose planes and the dose planes calculated by the Eclipse treatment planning system had exceeded the acceptable tolerance levels. When used as described in this study, HPlusQA can reduce the need for patient specific quality assurance measurements by 64%. The authors believe that the use of HPlusQA as a dose calculation second check can increase the efficiency and effectiveness of the QA process.

Mackin, Dennis; Li, Yupeng; Taylor, Michael B.; Kerr, Matthew; Holmes, Charles; Sahoo, Narayan; Poenisch, Falk; Li, Heng; Lii, Jim; Amos, Richard; Wu, Richard; Suzuki, Kazumichi; Gillin, Michael T.; Zhu, X. Ronald; Zhang, Xiaodong [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)] [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

2013-12-15T23:59:59.000Z

355

Quality assessment: A performance-based approach to assessments  

SciTech Connect (OSTI)

Revision C to US Department of Energy (DOE) Order 5700.6 (6C) ``Quality Assurance`` (QA) brings significant changes to the conduct of QA. The Westinghouse government-owned, contractor-operated (GOCO) sites have updated their quality assurance programs to the requirements and guidance of 6C, and are currently implementing necessary changes. In late 1992, a Westinghouse GOCO team led by the Waste Isolation Division (WID) conducted what is believed to be the first assessment of implementation of a quality assurance program founded on 6C.

Caplinger, W.H.; Greenlee, W.D.

1993-08-01T23:59:59.000Z

356

In Vivo Monitoring Program Manual, PNL-MA-574, Rev 5.1  

SciTech Connect (OSTI)

The following sections provide an overview of the administration for the In Vivo Monitoring Program (IVMP) for Hanford. This includes the organizational structure and program responsibilities; coordination of in vivo measurements; scheduling measurements; performing measurements; reporting results; and quality assurance.

Lynch, Timothy P.

2011-09-12T23:59:59.000Z

357

Assuring the Quality of Test Results in the Field of Nuclear Techniques and Ionizing Radiation. The Practical Implementation of Section 5.9 of the EN ISO/IEC 17025 Standard  

SciTech Connect (OSTI)

The paper aims to present a practical approach for testing laboratories to ensure the quality of their test results. It is based on the experience gained in assessing a large number of testing laboratories, discussing with management and staff, reviewing results obtained in national and international PTs and ILCs and exchanging information in the EA laboratory committee.According to EN ISO/IEC 17025, an accredited laboratory has to implement a programme to ensure the quality of its test results for each measurand. Pre-analytical, analytical and post-analytical measures shall be applied in a systematic manner. They shall include both quality control and quality assurance measures.When designing the quality assurance programme a laboratory should consider pre-analytical activities (like personnel training, selection and validation of test methods, qualifying equipment), analytical activities ranging from sampling, sample preparation, instrumental analysis and post-analytical activities (like decoding, calculation, use of statistical tests or packages, management of results).Designed on different levels (analyst, quality manager and technical manager), including a variety of measures, the programme shall ensure the validity and accuracy of test results, the adequacy of the management system, prove the laboratory's competence in performing tests under accreditation and last but not least show the comparability of test results.Laboratory management should establish performance targets and review periodically QC/QA results against them, implementing appropriate measures in case of non-compliance.

Cucu, Daniela [Romanian Accreditation Body, RENAR, Bucharest (Romania); Woods, Mike [Ionising Radiation Metrology Consultants Ltd, Teddington, Middlesex TW 11 9PQ (United Kingdom)

2008-08-14T23:59:59.000Z

358

Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance  

SciTech Connect (OSTI)

To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatment sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.

Ali, Imad, E-mail: iali@ouhsc.edu [Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Ahmad, Salahuddin [Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

2013-10-01T23:59:59.000Z

359

Quality Assurance Exchange, April 2009  

Broader source: Energy.gov (indexed) [DOE]

as Six Sigma puts standardized statistical tools in the hands of the masses, Lean puts industrial engineering tools in the hands of those close to the work. 5. Choosing a...

360

CARD No. 22 Quality Assurance  

E-Print Network [OSTI]

in the public docket (Air Docket A-93-02) or from the addresses noted below: Ã? Three (3) standards for nuclear of Mechanical Engineers Service Center 22 Law Drive, P.O. Box 2900 Fairfield, New Jersey 07707-2900 (800) 843-2763 22-1 #12;Ã? NUREG-1297, Peer Review for High Level Nuclear Waste Repositories, is referenced in 40

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Quality Assurance Exchange April 2007  

Broader source: Energy.gov (indexed) [DOE]

to use our grading levels if they are different from those suggested in the Guide? DOE Order 414.1C requires grading levels to be established, documented, and approved in the QAP....

362

Weapons Quality Assurance Qualification Standard  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomen Owned SmallOf The 2012NuclearBradleyBudget Water PowerLast Saturday |the5-2008

363

Quality Assurance Exchange August 2011  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power.pdf11-161-LNG |September 15,2015 | DepartmentLoans | Department of-Director's Note The

364

Quality Assurance Policy, Revision 1  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems Engineering Research and DevelopmentDepartmentin Design Guidance

365

Quality Assurance Requirements and Description  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems Engineering Research and DevelopmentDepartmentin Design

366

Signed Quality Assurance Hub Memo  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power.pdf11-161-LNGInternational Energy Agency |AwardJohnson, Steve5,Shiprock ArchivedAction :I I!

367

E-Print Network 3.0 - assuring operational practicality Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Context Since the early 1990s there has been a much more overt focus on quality assurance... successor, the Quality Assurance Agency (QAA), created in 1997. In 2001, the...

368

EVALUATION OF LEACHATE QUALITY FROM PENTACHLOROPHENOL, CREOSOTE AND ACA  

E-Print Network [OSTI]

-chlorinated phenols, resin acids and f~h toxicity. A quality assurance and quality control (QA/QC) program#12;EVALUATION OF LEACHATE QUALITY FROM PENTACHLOROPHENOL, CREOSOTE AND ACA PRESERVED WOOD PRODUCTS, total organic carbon, ammonia, metals, polynuclear aromatic hydrocarbons (PAH), chlorinated and non

369

CR mammography: Design and implementation of a quality control program  

SciTech Connect (OSTI)

Despite the recent acquisition of significant quantities of computed radiography CR equipment for mammography, Mexican regulations do not specify the performance requirements for digital systems such as those of CR type. The design of a quality control program QCP specific for CR mammography systems was thus considered relevant. International protocols were taken as reference to define tests, procedures and acceptance criteria. The designed QCP was applied in three CR mammography facilities. Important deficiencies in spatial resolution, noise, image receptor homogeneity, artifacts and breast thickness compensation were detected.

Moreno-Ramirez, A.; Brandan, M. E.; Villasenor-Navarro, Y.; Galvan, H. A.; Ruiz-Trejo, C. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, DF 04510 (Mexico); Departamento de Radiodiagnostico, Instituto Nacional de Cancerologia, DF 14080 (Mexico); Instituto de Fisica, Universidad Nacional Autonoma de Mexico, DF 04510 (Mexico)

2012-10-23T23:59:59.000Z

370

The feasibility study and characterization of a two-dimensional diode array in “magic phantom” for high dose rate brachytherapy quality assurance  

SciTech Connect (OSTI)

Purpose: High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly {sup 192}Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 ?Gy m{sup 2}/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named “magic phantom.”Methods: The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array “magic plate” (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the {sup 192}Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a {sup 192}Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ.Results: The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm the relative response of the epitaxial diodes used in the MP is in good agreement (within 8%) with radial dose function measurements found within the TG-43 protocol, with SDD of up to 70 mm showing a 40% over response. A method for four-dimensional localization of the HDR source was developed, allowing the source dwell position to be derived within 0.50 mm of the expected position. An estimation of the average transit speed for varying step sizes was determined and was found to increase from (12.8 ± 0.3) up to (38.6 ± 0.4) cm/s for a step size of 2.5 and 50 mm, respectively.Conclusions: Our characterization of the designed QA “magic phantom” with MP in realistic HDR photon fields demonstrates the promising performance for real-time source position tracking in four dimensions and measurements of transit times. Further development of this system will allow a full suite for QA in HDR brachytherapy and analysis, and for future in vivo tracking.

Espinoza, A.; Beeksma, B.; Petasecca, M.; Fuduli, I.; Porumb, C.; Cutajar, D.; Lerch, M. L. F.; Rosenfeld, A. B. [Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522 (Australia)] [Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522 (Australia); Corde, S.; Jackson, M. [Department of Radiation Oncology, Prince of Wales Hospital, New South Wales 2031 (Australia)] [Department of Radiation Oncology, Prince of Wales Hospital, New South Wales 2031 (Australia)

2013-11-15T23:59:59.000Z

371

E-Print Network 3.0 - assurance implementation plan Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Collection: Computer Technologies and Information Sciences 14 Quality system for the educational activities at the University of Oslo (last update 6 July 2010) QUALITY ASSURANCE...

372

E-Print Network 3.0 - assurance division european Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

division european Page: << < 1 2 3 4 5 > >> 1 Standards and Guidelines for Quality Assurance in the European Higher Education Area Summary: Standards and Guidelines for Quality...

373

Space Telescope Programs Hubble Observatory  

E-Print Network [OSTI]

Assurance/Configuration Management Mr. Christopher Scholz EAG QA Manager #12;Space Telescope Programs Hubble · COS-UCB-002 QA Implementation Plan Released December 1, 1999 · COS-UCB-003 CM Plan released DecemberSpace Telescope Programs Hubble Observatory HST-COS FUV PER 11/8/00 FUV Detector System Quality

Colorado at Boulder, University of

374

EPA Tribal Training and Outreach Support for the American Indian Air Quality Training Program  

Broader source: Energy.gov [DOE]

The U.S. Environmental Protection Agency (EPA) is accepting applications to provide training, and technical and outreach support for the American Indian Air Quality Training Program.

375

Integrated Safety Management in QA Program Planning  

Broader source: Energy.gov [DOE]

Presenter: Sonya Barnette, Office of Quality Assurance Policy and Assistance, Office of Nuclear Safety, Quality Assurance and Environment Track 9-8

376

DOE-ER-STD-6001-92; Implementation Guide for Quality Assurance Programs for Basic and applied Research  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Deliciouscritical_materials_workshop_presentations.pdf MoreProgramofContractto Host aDesignDOE's Use

377

Annual Monitoring Results A REPORT OF THE REGIONAL MONITORING PROGRAM  

E-Print Network [OSTI]

Grainsize 33 Total Organic Carbon (TOC) and Total Nitrogen (TN)33 Trace Metals34 Trace Organics34 Quality Assurance / Quality Control (QA/QC) 37 QA/QC of Percent Solids37 QA/QC of Grain Size 37 QA/QC of TotalAnnual Monitoring Results 2012 A REPORT OF THE REGIONAL MONITORING PROGRAM FOR WATER QUALITY

378

Infrastructure Assurance Center  

E-Print Network [OSTI]

, the United States relied on natural gas to meet about 22% of its energy needs. Therefore, assuring efficient, natural gas processing plants, and other industrial customers, along with the changes in the utilizationInfrastructure Assurance Center NGReal-time: processing and analysis tool for natural gas delivery

379

ASSURANCES - NON-CONSTRUCTION PROGRAMS  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecemberSteam Coal Import CostsLiquids Reserve3.Revenue3 Oil and(Million OMB Number:

380

Assurances - Non-Construction Programs  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3--Logistical Challenges toReport | DepartmentAppropriationsAssociation of Home

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

66 USDA Forest Service Gen. Tech. Rep. PSW-GTR-155. 1996. Quality Assurance, Training, and Certification in Ozone Air Pollution Studies Schilling, Miller, and Takemoto  

E-Print Network [OSTI]

, and Certification in Ozone Air Pollution Studies Schilling, Miller, and Takemoto Air Resources Board. 1990 air quality standards--1990 Update. Mailout No. 90­ 68. Mobile Source Division, On­Road­Control data: summary of 1990 air quality data-- gaseous and particulate pollutants. Annual summary. Technical

Standiford, Richard B.

382

ACADEMIC SENATE POLICY #S06-238 INDICATORS AND STANDARDS OF GRADUATE PROGRAM QUALITY AND SUSTAINABILITY  

E-Print Network [OSTI]

AND SUSTAINABILITY An explicit goal of the University's 2005-2010 strategic plan is that the institution "offers high program quality and sustainability"2 and for the integration of those standards into a "revised process to demonstrate whether University-wide and program-specific indicators and standards of program sustainability

383

E-Print Network 3.0 - assurance systems engineering Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Information Sciences 7 STEM Degrees NOT Eligible for 17 Month Extension SU Program Name CIP Code Program Name on SEVIS I-20 Summary: and Information Scien Systems Assurance...

384

Corporate Sustainability Reporting: Investigation of Assurance Process, Assurance Characteristics and Assurance Frameworks Used  

E-Print Network [OSTI]

This dissertation is on assured sustainability reporting. It has three parts that are titled as follows: Part 1. Planning Assurance Services for Sustainability Reporting: An Analysis of Cost versus Assurance in Audit ...

Rao, Sunita

2012-08-31T23:59:59.000Z

385

assurance test method: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

assurance test method First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Quality Assurance of Test...

386

assurance plan revision: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

assurance plan revision First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 QUALITY ASSURANCE MANUAL...

387

E-Print Network 3.0 - automotive quality systems Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Quality Assurance of Automotive Software Jan Jrjens1 , Daniel Reiss2 , David... (Germany) 12;Jan Jrjens et al.: Model-based Quality Assurance of Automotive Software 2 The...

388

Notice of Intent to Revise DOE G 414.1-1B, Management and Independent Assessments Guide for Use with 10 CFR, Part 830, Subpart A, and DOE O 414.1C, Quality Assurance; DOE M 450.4-1, Integrated Safety Management System Manual; and DOE O 226.1A  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This memorandum provides justification for revising DOE G 414.1-1B, Management and Independent Assessments Guide for Use With 10 CFR, Part 830, Subpart A, and DOE O 414.1C, Quality Assurance; DOE M 450.4-1, Integrated Safety Management System Manual; and DOE O 226.1A, Implementation of Department of Energy Oversight Policy.

2013-04-18T23:59:59.000Z

389

A cost/benefit model for insertion of technological innovation into a total quality management program  

E-Print Network [OSTI]

This study provides economic justification for insertion of technological innovation into a total quality management (TQM) program in a remanufacturing environment. One of the core principles of TQM is continuous improvement. A preferred metric...

Ratliff, William L

1997-01-01T23:59:59.000Z

390

after-school program quality: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

system will help keep your water safe. For more information, visit the Virginia Household Water Quality Program website at www.wellwater.bse. vt.edu. unknown authors 25...

391

air quality program: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit 68 Predicting Air Quality: Current Status...

392

Building Air Quality Alliance Program fro Building Management  

E-Print Network [OSTI]

Indoor air quality (IAQ) has emerged as a major concern for building owners, managers, engineers and tenants. As the public recognizes the importance of healthy, comfortable. and productive indoor environments, their awareness and demand for good...

Kettler, G. J.

1998-01-01T23:59:59.000Z

393

Stanford University HRPP Continuous Quality Improvement (CQI) Program  

E-Print Network [OSTI]

/13 Research Compliance Office STANFORD measures and improves, when necessary, compliance with organizational measures and improves, when necessary, the quality, effectiveness, and efficiency of the Human Research to assess compliance with organizational policies and procedures and applicable laws, regulations, codes

Puglisi, Joseph

394

Foreign criteria and programs  

SciTech Connect (OSTI)

The concept of measurement quality assurance (MQA) as embodied in National Institute of Standards and Technology (NIST) programs is not generally used within European programs for testing or accreditation. Although the essential elements of quality control and quality assurance are in the European programs, the concept of testing the capability of the laboratory itself, in terms of its performance for the designated measurements, may not be included. Rather, the European programs use the concept of periodic calibration of laboratory reference standards against the next highest level of standards. Thus, they embody the concept of measurement traceability to appropriate primary standards. Within Europe a series of calibration accreditation programs has been established in the various countries tied together through a multilateral agreement. The radiation measurement programs are based on the International Organization for Standardization (ISO) 9000 series of standards. The purpose of this paper is to outline the overall operation of European Accreditation Programs in the radiation calibration and measurement areas. The operation of the radiation measurement programs of the National Measurement Accreditation Service (NAMAS) in the United Kingdom is described in detail along with other European programs. The manner in which these programs relate to individual dosimetry service programs is also described.

Swinth, K.L. [Pacific Northwest Lab., Richland, WA (United States); Thompson, I.M.G. [Thompson (I.M.G.), Glouchestershire (United Kingdom)

1993-03-01T23:59:59.000Z

395

Satellite Navigation Integrity Assurance: Lessons Learned  

E-Print Network [OSTI]

Satellite Navigation Integrity Assurance: Lessons Learned from Hurricane Katrina ION GNSS 2008 by the FAA Satellite Navigation Program Office #12;17 September 2008 Lessons Learned from Hurricane Katrina 2 for probabilistic modeling and analysis #12;17 September 2008 Lessons Learned from Hurricane Katrina 3 Key Sources

Stanford University

396

E-Print Network 3.0 - assurance sampling method Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

for NRDA followed standard operating procedure (SOP), water sampling plans, Summary: procedures, and NOAA's Analytical Quality Assurance Project Plan (QAPP). Samples were sent to...

397

E-Print Network 3.0 - assurance plan project Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

for NRDA followed standard operating procedure (SOP), water sampling plans, Summary: procedures, and NOAA's Analytical Quality Assurance Project Plan (QAPP). Samples were sent...

398

E-Print Network 3.0 - assurance requirements document Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Approval Documentation Due Diligence (Formerly APA1) Quality Management and Assurance... documentation Full Abridged Not required Required Not required Decision to be...

399

E-Print Network 3.0 - assurance working party Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Standards and Technology Collection: Chemistry 2 Standards and Guidelines for Quality Assurance in the European Higher Education Area Summary: . The credibility of the work of...

400

E-Print Network 3.0 - assurance electronic resource Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

for the risk. NIST's Software Assurance Metrics Source: Black, Paul E. - Software Quality Group, National Institute of Standards and Technology (NIST) Collection: Computer...

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

E-Print Network 3.0 - assuring blood safety Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dMedaicalSchoolBloodCenterPublicationFall2004 Summary: and patients safe. The Quality Assurance Department keeps the Stanford Blood Center in compliance with safety... equipment....

402

How to implement a quality program in a coking plant. The AHMSA experience  

SciTech Connect (OSTI)

AHMSA (Altos Hornos de Mexico) is the largest integrated Steel Plant in Mexico, with its 3.1 MMMT of Liquid Steel production program for 1995. AHMSA operates two coke plants which began operations in 1955 and 1976. Total coke monthly production capacity amounts to as much as 106,000 Metric Tons (MT). The coke plants working philosophy was discussed and established in 1986 as part of the Quality Improvement Program, where its ultimate goal is to give the best possible coke quality to its main client--the blast furnaces. With this goal in mind, a planned joint effort with their own coal mines was initiated. This paper deals with the implementation process of the Quality Program, and the results of this commitment at the coal mines, coke plants and blast furnaces. The coke quality improvement is shown since 1985 to 1994, as well as the impact on the blast furnace operation.

Reyes M, M.A.; Perez, J.L.; Garza, C. de la; Morales, M.

1995-12-01T23:59:59.000Z

403

A Report of the Regional Monitoring Program for Water Quality in the San Francisco Estuary pollutant effects on aquatic life  

E-Print Network [OSTI]

Program for Water Quality in the San Francisco Estuary 2011 pollutant effects on aquatic life pulse goals of Bay water quality managers is to ensure that pollutants do not interfere with the abilityA Report of the Regional Monitoring Program for Water Quality in the San Francisco Estuary

404

Infrastructure Assurance Center  

E-Print Network [OSTI]

and impact-analysis tool developed by Argonne National Laboratory. This powerful tool allows for rapid, first in which flooding of the Savannah River along the South Carolina/Georgia border caused a 25% reduction Assurance Center Our nation relies on natural gas to meet about 22% of its energy needs. Within the next 10

Kemner, Ken

405

Hybrid Vehicle Program. Final report  

SciTech Connect (OSTI)

This report summarizes the activities on the Hybrid Vehicle Program. The program objectives and the vehicle specifications are reviewed. The Hybrid Vehicle has been designed so that maximum use can be made of existing production components with a minimum compromise to program goals. The program status as of the February 9-10 Hardware Test Review is presented, and discussions of the vehicle subsystem, the hybrid propulsion subsystem, the battery subsystem, and the test mule programs are included. Other program aspects included are quality assurance and support equipment. 16 references, 132 figures, 47 tables.

None

1984-06-01T23:59:59.000Z

406

The Multi-Scale Mass Transfer Processes Controlling Natural Attenuation and Engineered Remediation: An IFC Focused on Hanford’s 300 Area Uranium Plume Quality Assurance Project Plan  

SciTech Connect (OSTI)

The purpose of the project is to conduct research at an Integrated Field-Scale Research Challenge Site in the Hanford Site 300 Area, CERCLA OU 300-FF-5 (Figure 1), to investigate multi-scale mass transfer processes associated with a subsurface uranium plume impacting both the vadose zone and groundwater. The project will investigate a series of science questions posed for research related to the effect of spatial heterogeneities, the importance of scale, coupled interactions between biogeochemical, hydrologic, and mass transfer processes, and measurements/approaches needed to characterize a mass-transfer dominated system. The research will be conducted by evaluating three (3) different hypotheses focused on multi-scale mass transfer processes in the vadose zone and groundwater, their influence on field-scale U(VI) biogeochemistry and transport, and their implications to natural systems and remediation. The project also includes goals to 1) provide relevant materials and field experimental opportunities for other ERSD researchers and 2) generate a lasting, accessible, and high-quality field experimental database that can be used by the scientific community for testing and validation of new conceptual and numerical models of subsurface reactive transport.

Fix, N. J.

2008-01-31T23:59:59.000Z

407

A study of auditing methodologies for the Energy Information Administration data collection and processing system quality assessment program  

SciTech Connect (OSTI)

Since FY83 the Oak Ridge National Laboratory (ORNL) has assisted the Department of Energy's (DOE's) Energy Information Administration (EIA) Quality Assurance Division, Office of Statistical Standards (OSS), with assessments of the quality of EIA's automated data collection and processing systems. These assessments have had three objectives: to determine whether the survey systems collect, process, and publish accurate and reliable information; to ensure that the system documentation is current and adequate; and to evaluate the systems' compliance with applicable EIA standards. By the end of CY89 over 40 different EIA data survey systems will have been audited. This will complete the first round of EIA auditing. 17 refs.

Truett, L.F.; Yow, T.G.

1989-11-01T23:59:59.000Z

408

A Generic Environment for COTS Testing and Quality Prediction  

E-Print Network [OSTI]

they inherit. Quality assurance (QA) characteristics of component systems, and the life cycle of component a QA model for CBSD. The model covers the eight main processes in component-based software systems (CBS) development. A Component-based Program Analysis and Reliability Evaluation (ComPARE) environment

Lyu, Michael R.

409

In Cooperation with the National Park Service Water Quality Program Biogeochemical Processes in an Urban, Restored  

E-Print Network [OSTI]

In Cooperation with the National Park Service Water Quality Program Biogeochemical Processes in an Urban, Restored Wetland of San Francisco Bay, California, 2007­ 2009: Methods and Data for Plant, Sediment, and Water Parameters By Lisamarie Windham-Myers, Mark C. Marvin-DiPasquale, Jennifer L. Agee, Le

410

Quality Managment Program (QMP) report: A review of quality management programs developed in response to Title 10, Section 35.32 of the Code of Federal Regulations  

SciTech Connect (OSTI)

In July of 1991, the Nuclear Regulatory Commission published a Final Rule in the Federal Register amending regulations governing medical therapeutic administrations of byproduct material and certain uses of radioactive sodium iodide. These amendments required implementation of a Quality Management Program (QMP) to provide high confidence that the byproduct material -- or radiation from byproduct material -- will be administered as directed by an authorized user physician. Herein, this rule is referred to as the QM rule. The Final Rule was published after two proposed rules had been published in the Federal Register.

Witte, M.C.

1994-10-01T23:59:59.000Z

411

EM Quality Assurance Policy, Revision 0  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProvedDecember 2005Department ofDOEDisabilityContractors forProcurementsEM-QA-001Office of

412

Quality Assurance - DOE Directives, Delegations, and Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassive Solar HomePromising Science for1 2011 Publications Wood,Quadrennial4.1D Admin

413

Quality assurance | Princeton Plasma Physics Lab  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassive Solar HomePromising Science for1 2011 Publications Wood,Quadrennial4.1DQuality

414

Quality Assurance Checklist | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Careerlumens_placard-green.epsEnergy1.pdfMarket37963 Vol.Department ofchecklist is intended to

415

Quality Assurance Functional Area Qualification Standard  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Careerlumens_placard-green.epsEnergy1.pdfMarket37963 Vol.Department ofchecklist isEnergyNOT

416

Quality Assurance for Critical Decision Reviews RM  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power.pdf11-161-LNG |September 15,2015 | DepartmentLoans | Department of-Director'sPolicy

417

Report: Acquisition, Project Management, and Quality Assurance  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power.pdf11-161-LNG |September 15,2015Department of Energy on Separate

418

Safety & Quality Assurance | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 -the Mid-Infrared0 ResourceAwardsSafeguards and Security Systems SHARESafer

419

Quality assurance in the Brenham Residue Lab  

E-Print Network [OSTI]

the methylene chloride layer through sodium sulfate into a 588 mL Kurdina-Danish flask with a 18 mL Mills Tube. Add 1 or 2 Carborundum boiling chips and attach a Snyder column and evaporate on a steam bath to about 2 mL. Take this to dzyness on a N...

Jackson, Jerry

1988-01-01T23:59:59.000Z

420

2012 Quality Assurance Improvement Project Plan  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems Engineering ResearchServices4/08VirginiaOsuna- FLIGHTTEPPDepartment2012 NuclearDOE

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Software Quality Assurance Control of Existing Systems  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energyof the Americas |DOEEnergy Smooth Brome MonitoringSoftware

422

Quality Assurance Corporate Board | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' Research | DepartmentDepartmentHatch, Maryanne5 Updatescomments August 8, 2014Office

423

Quality Assurance Requirements | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' Research | DepartmentDepartmentHatch, Maryanne5 Updatescomments August 8,TheThe QARD

424

Quality Assurance Rule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' Research | DepartmentDepartmentHatch, Maryanne5 Updatescomments August 8,TheThe

425

Performance and Quality Assurance | National Nuclear Security  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofofOxfordVeteransAdministration MayLifeOverviewpaperEvaluations

426

SOPP-43, EM-23 Quality Assurance Oversight  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l LPROJECTS IN7 Roadmap forDKT.Awards andeere.energy.gov| POLICY: The

427

EM Quality Assurance Assessment Schedule FY 2010  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power SystemsResources DOE ZeroThreeEnergyDepartment0: DOE512: AlaskaDR. STFDlN L. KRAHN

428

Princeton Plasma Physics Lab - Quality assurance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - SeptemberMicroneedles for4-16 FOR Primary Author

429

Quality Assurance - DOE Directives, Delegations, and Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - SeptemberMicroneedlesAdvancedJanuary 13,PuttingEnergy QER1

430

Quality Assurance Functional Area Qualification Standard - DOE  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - SeptemberMicroneedlesAdvancedJanuary 13,PuttingEnergy QER1Directives,

431

Quality Assurance Functional Area Qualification Standard - DOE  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - SeptemberMicroneedlesAdvancedJanuary 13,PuttingEnergy

432

2010 Quality Assurance Improvement Project Plan  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems Engineering ResearchServices4/08VirginiaOsuna- FLIGHT - -July05 WaysSmart0

433

FAQS Job Task Analyses- Quality Assurance  

Broader source: Energy.gov [DOE]

FAQS Job Task Analyses are performed on the Function Area Qualification Standards. The FAQS Job Task Analyses consists of: Developing a comprehensive list of tasks that define the job such as the duties and responsibilities which include determining their levels of importance and frequency. Identifying and evaluating competencies. Last step is evaluating linkage between job tasks and competencies.

434

2014 Florida NRCS Programs Environmental Quality Incentives Program (EQIP) provides financial and technical  

E-Print Network [OSTI]

and technical assistance to help plan and implement conservation practices to improve soil, water, plant, animal wildlife habitat of National, State, Tribal, or local significance. Conservation Stewardship Program (CSP

Watson, Craig A.

435

OIA: Office of Contractor Assurance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

for science, best management practices, and continuous improvement are achieved at LBNL. The OCA is an internal independent assurance organization, and is authorized to have...

436

Deep in the Forests: Program works to protect water quality through forestry practices  

E-Print Network [OSTI]

20 tx H2O Winter 2011 Story by Kathy Wythe The Texas Forest Service works with forestry professionals to implement best management practices to help protect water quality, which is critical for people and wildlife to survive. Photo courtesy... of Texas Forest Service. Deep in the forests Program works to protect water quality through forestry practices Winter 2011 tx H2O 21 ] Deep in the forests of East Texas and sca#27;ered in pockets of other parts of the state are more than...

Wythe, Kathy

2011-01-01T23:59:59.000Z

437

Deep in the forests: Program works to protect water quality through forestry practices  

E-Print Network [OSTI]

20 tx H2O Winter 2011 Story by Kathy Wythe The Texas Forest Service works with forestry professionals to implement best management practices to help protect water quality, which is critical for people and wildlife to survive. Photo courtesy... of Texas Forest Service. Deep in the forests Program works to protect water quality through forestry practices Winter 2011 tx H2O 21 ] Deep in the forests of East Texas and sca#27;ered in pockets of other parts of the state are more than...

Wythe, Kathy

2011-01-01T23:59:59.000Z

438

Multifamily Quality Control Inspector Job/Task Analysis and Report: September 2013  

SciTech Connect (OSTI)

The development of job/task analyses (JTAs) is one of three components of the Guidelines for Home Energy Professionals project and will allow industry to develop training resources, quality assurance protocols, accredited training programs, and professional certifications. The Multifamily Quality Control Inspector JTA identifies and catalogs all of the tasks performed by multifamily quality control inspectors, as well as the knowledge, skills, and abilities (KSAs) needed to perform the identified tasks.

Owens, C. M.

2013-09-01T23:59:59.000Z

439

Semi-annual report of the Department of Energy, Office of Environmental Management, Quality Assessment Program  

SciTech Connect (OSTI)

This Quality Assessment Program (QAP) is designed to test the quality of the environmental measurements being reported to the Department of Energy by its contractors. Since 1976, real or synthetic environmental samples that have been prepared and thoroughly analyzed at the Environmental Measurements Laboratory (EML) have been distributed at first quarterly and then semi-annually to these contractors. Their results, which are returned to EML within 90 days, are compiled with EML`s results and are reported back to the participating contractors 30 days later. A summary of the reported results is available to the participants 4 days after the reporting deadline via the Internet at www.eml.doe.gov. This report presents the results from the analysis of the 47th set of environmental quality assessment samples (QAP XLVII) that were received on or before December 1, 1997.

Greenlaw, P.D.

1998-01-01T23:59:59.000Z

440

Semi-annual report of the Department of Energy, Office of Environmental Management, Quality Assessment Program  

SciTech Connect (OSTI)

This Quality Assessment Program (QAP) is designed to test the quality of the environmental measurements being reported to the Department of Energy by its contractors. Since 1976, real or synthetic environmental samples that have been prepared and thoroughly analyzed at the Environmental Measurements Laboratory (EML) have been distributed at first quarterly and then semi-annually to these contractors. Their results, which are returned to EML within 90 days, are compiled with EML`s results and are reported back to the participating contractors 30 days later. This report presents the results from the analysis of the 48th set of environmental quality assessment samples (QAP XLVIII) that were received on or before June 1, 1998.

Greenlaw, P.D.; Minick, S.K.

1998-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

The effect of an employee educational program on the bacteriological quality of blue crab meat  

E-Print Network [OSTI]

University Chairman of Advisory Committee: Dr. R. Nickelson II Employee educational programs were used in various food processing plants to improve the plant sanitation. Little 1;terature had been reported on the effect of sanitation workshops... on the sanitation prac- tices of employees, productivity of the plant, product. yields, and microbiological quality of the finished product. Two different blue crab processing plants along the Texas coast were monitored for aerobic plate counts (APC), coliforms...

Biediger, Catherine M

1978-01-01T23:59:59.000Z

442

Youth Water Camp: Ward County 4-H program educates students about water conservation, quality  

E-Print Network [OSTI]

tx H2O | pg. 24 A plant chemist directs Water Camp youth in basic water analysis at a local power plant during a tour. Story by Danielle Supercinski Ward County 4-H program educates students about water conservation, quality In January... 1991, a committee of the Texas Agricultural Extension Service (now Texas AgriLife Extension Service) and Upper Pecos Soil and Water Conservation District person- nel met on the development of a 4-H water camp educating youth on water issues...

Supercinski, Danielle

2008-01-01T23:59:59.000Z

443

In Vivo Monitoring Program Manual, PNL-MA-574  

SciTech Connect (OSTI)

An overview of the administration for the In Vivo Monitoring Program (IVMP) for Hanford. This includes organizational structure and program responsibilities; coordination of in vivo measurements; scheduling measurements; performing measurements; reporting results; and quality assurance. Overall responsibility for the management of the IVMP rests with the Program Manager (PM). The PM is responsible for providing the required in vivo counting services for Hanford Site contractor employees in accordance with Department of Energy (DOE) requirements and the specific statements of work.

Lynch, Timothy P.

2010-07-01T23:59:59.000Z

444

High-Assurance Software: LDRD Report.  

SciTech Connect (OSTI)

This report summarizes our work on methods for developing high-assurance digital systems. We present an approach for understanding and evaluating trust issues in digital systems, and for us- ing computer-checked proofs as a means for realizing this approach. We describe the theoretical background for programming with proofs based on the Curry-Howard correspondence, connect- ing the field of logic and proof theory to programs. We then describe a series of case studies, intended to demonstrate how this approach might be adopted in practice. In particular, our stud- ies elucidate some of the challenges that arise with this style of certified programming, including induction principles, generic programming, termination requirements, and reasoning over infinite state spaces.

Hulette, Geoffrey Compton

2014-06-01T23:59:59.000Z

445

Security Policy Testing via Automated Program Code Generation (Extended Abstract)  

E-Print Network [OSTI]

-language-specific coverage crite- ria [5, 6] and test generation algorithms [4, 5]. One limitation of these previous testingSecurity Policy Testing via Automated Program Code Generation (Extended Abstract) Ting Yu North's sophisticated access control policies. Similar to quality assurance of software systems, testing techniques [4

Xie, Tao

446

Organization as Innovation: China’s Human Spaceflight Program’s Efforts to Instill a Quality Management System  

E-Print Network [OSTI]

to Instill a Quality Management System Kevin Pollpeterthat China’s quality management system was not suitable to

Pollpeter, Kevin

2011-01-01T23:59:59.000Z

447

Hanford performance evaluation program for Hanford site analytical services  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) Order 5700.6C, Quality Assurance, and Title 10 of the Code of Federal Regulations, Part 830.120, Quality Assurance Requirements, states that it is the responsibility of DOE contractors to ensure that ``quality is achieved and maintained by those who have been assigned the responsibility for performing the work.`` Hanford Analytical Services Quality Assurance Plan (HASQAP) is designed to meet the needs of the Richland Operations Office (RL) for maintaining a consistent level of quality for the analytical chemistry services provided by contractor and commmercial analytical laboratory operations. Therefore, services supporting Hanford environmental monitoring, environmental restoration, and waste management analytical services shall meet appropriate quality standards. This performance evaluation program will monitor the quality standards of all analytical laboratories supporting the Hanforad Site including on-site and off-site laboratories. The monitoring and evaluation of laboratory performance can be completed by the use of several tools. This program will discuss the tools that will be utilized for laboratory performance evaluations. Revision 0 will primarily focus on presently available programs using readily available performance evaluation materials provided by DOE, EPA or commercial sources. Discussion of project specific PE materials and evaluations will be described in section 9.0 and Appendix A.

Markel, L.P.

1995-09-01T23:59:59.000Z

448

S/w Quality Assurance CAST-TX 1 Software Quality Assurance  

E-Print Network [OSTI]

and complexity massive user population · How to meet the new challenges: multiple QA alternatives selective/usage, technology, process, tools Formal verification (faults absent) · Removal of faults Inspection: faults One of the most important part of QA What: black vs. white box When to stop: coverage vs. usage

Tian, Jeff

449

Software Quality Assurance Guide for Use with DOE O 414.1D, Quality Assurance  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The revision to DOE G 414.1-4 will conform to the revised DOE O 414.1D and incorporate new information and lessons learned since 2005, including information gained as a result of the February 2011, Government Accountability Office (GAO) report, GAO-11-143 NUCLEAR WASTE: DOE Needs a Comprehensive Strategy and Guidance on Computer Models that Support Environmental Cleanup Decisions.

2015-02-04T23:59:59.000Z

450

Quality Assurance forQuality Assurance for Security-Critical SystemsSecurity-Critical Systems  

E-Print Network [OSTI]

Munich Extensive collaboration with industry (BMW,Extensive collaboration with industry (BMW, Hypo (rather than breaking) them.breaking) them. Assumptions on system context, physical environment.Assumptions on system context, physical environment. Attacker may use unintended/unnoticed functionalityAttacker may

Jurjens, Jan

451

Measurement Assurance Program for Wavelength Dependence of  

E-Print Network [OSTI]

and Selected MAP Results ...... 15 Appendix C, Qualification of Artifacts and Measurement System is intended for the calibration of PDL measurement equipment, and is not intended for the simulation of PDL

452

EMERGENCY READINESS ASSURANCE PLAN (ERAP) FOR FISCAL YEAR (FY) 2014  

SciTech Connect (OSTI)

This Emergency Readiness Assurance Plan (ERAP) for Fiscal Year (FY) 2014 in accordance with DOE O 151.1C, “Comprehensive Emergency Management System.” The ERAP documents the readiness of the INL Emergency Management Program using emergency response planning and preparedness activities as the basis. It describes emergency response planning and preparedness activities, and where applicable, summarizes and/or provides supporting information in tabular form for easy access to data. The ERAP also provides budget, personnel, and planning forecasts for FY-15. Specifically, the ERAP assures the Department of Energy Idaho Operations Office that stated emergency capabilities at INL are sufficient to implement PLN-114, “INL Emergency Plan/RCRA Contingency Plan.

Shane Bush

2014-09-01T23:59:59.000Z

453

Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Why Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data...

454

Environmental Technology Verification Coatings and Coating Equipment Program (ETV CCEP)  

E-Print Network [OSTI]

.2 Quality Assurance for the ETV CCEP.....................................................................1.................................................................11 2.2.12 Determination of Total Volatile Content of the UV-Curable Coating.......14 2.3 Schedule.0 QUALITY ASSURANCE OBJECTIVES.......................................

455

WE INVEST IN TECHNOLOGY. NOW LET US INVEST IN YOU. Leap Technology Program  

E-Print Network [OSTI]

WE INVEST IN TECHNOLOGY. NOW LET US INVEST IN YOU. Leap Technology Program Fidelity Investments innovation, and effective deployment of leading-edge technologies. Our entry-level technology training, Quality Assurance, Mainframe Development and Technology Infrastructure and Engineering (TIE). Upon

Virginia Tech

456

Office of Compliance Programs PRIVACY POLICY AND PROCEDURES Policy #: 2100.22  

E-Print Network [OSTI]

; · utilization review; · quality assurance; · billing; #12;Office of Compliance Programs PRIVACY POLICY and Accountability Act (HIPAA), Privacy, Security, Breach Notification, and Enforcement Rules at 45 CFR Part 160 and Part 164 ("HIPAA Rules") that relate to the disclosure of a patient's Protected Health Information

457

DOE CALiPER Program, Report 20.1 Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps  

SciTech Connect (OSTI)

This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members ranking of color quality did not always match the rank according to the color rendering index (CRI).

Royer, Michael P.; Poplawski, Michael E.; Miller, Naomi J.

2013-10-01T23:59:59.000Z

458

Residential Energy Efficiency Financing: Key Elements of Program Design  

Broader source: Energy.gov [DOE]

Presents key programmatic elements and context of financing initiatives, including contractor support, rebates, quality assurance, and more.

459

Results of The Excreta Bioassay Quality Control Program For April 1, 2010 Through March 31, 2011  

SciTech Connect (OSTI)

A total of 76 urine samples and 10 spiked fecal samples were submitted during the report period (April 1, 2010 through March 31, 2011) to GEL Laboratories, LLC in South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for 14C, Sr, for 238Pu, 239Pu, 241Am, 243Am, 235U, 238U, 238U-mass and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.1% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 31% of the analyses processed by GEL during the first year of contract 112512 were quality control samples. GEL tested the performance of 23 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty except the slightly elevated relative bias for 243,244Cm (Table 4).

Antonio, Cheryl L.

2012-07-19T23:59:59.000Z

460

Results of the Excreta Bioassay Quality Control Program For April 1, 2006 Through March 31, 2007  

SciTech Connect (OSTI)

A total of 66 urine samples, 6 blank fecal and 6 spiked artificial fecal samples were submitted during the report period (April 1, 2006 through March 31, 2007) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for tritium, Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.7% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 36% of the analyses processed by GEL during the second year of this contract were quality control samples. GEL tested the performance of 16 radioisotopes, all of which met or exceeded the specifications in the Statement of Work. IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved.

Antonio, Cheryl L.

2008-02-19T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Results of RCRA groundwater quality assessment program at the 216-U-12 crib  

SciTech Connect (OSTI)

The 216-U-12 crib has been in a Resource Conservation and Recovery Act of 1976 (RCRA) interim-status groundwater quality assessment program since the first quarter of 1993. Specific conductance measured in downgradient wells 299-W22-41 and 299-W22-42 exceeds its critical mean. This report presents the results and findings of Phases I and II of the assessment monitoring program, as required by 40 CFR 265.93. The elevated levels of specific conductance in the downgradient {open_quotes}triggering{close_quotes} wells are attributed to nitrate, the mobile anion released when nitric acid is diluted in water, and calcium which is released from the sediments as acid is neutralized. Technetium-99 levels have been elevated in these same downgradient wells since 1991. The source of these constituents is the 216-U-12 crib. Downward migration of nitrate and technetium-99 from the vadose zone (and continued elevated specific conductance in the two downgradient wells) is still occurring because the driving force is still present.

Williams, B.A.; Chou, C.J.

1997-05-01T23:59:59.000Z

462

Results of the Excreta Bioassay Quality Control Program for April 1, 2009 through March 31, 2010  

SciTech Connect (OSTI)

A total of 58 urine samples and 10 fecal samples were submitted during the report period (April 1, 2009 through March 31, 2010) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year as well as four tissue samples for 238Pu, 239Pu, 241Am and 241Pu. The number of QC urine samples submitted during the report period represented 1.3% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 33% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 21 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty (Table 4).

Antonio, Cheryl L.

2012-07-19T23:59:59.000Z

463

Quality Policy  

Broader source: Energy.gov [DOE]

Quality Policy It is the policy of the Department of Energy to establish quality requirements to ensure that risks and environmental impacts are minimized and that safety, reliability, and performance are maximized through the application of effective management systems commensurate with the risks posed by the facility or activity and its work. The Department implements this policy through the QA Order and the QA rule directives to ensure quality assurance requirements are clearly specified for the broad spectrum of work performed by DOE and its contractors.

464

DOE Vehicle Technologies Program 2009 Merit Review Report - Vehicle...  

Broader source: Energy.gov (indexed) [DOE]

benchmark test manual were developed and utilized. This comment is relevant to conduct of operations, data fidelity, test repeatability, quality control and quality assurance....

465

Hanford External Dosimetry Program  

SciTech Connect (OSTI)

This document describes the Hanford External Dosimetry Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy (DOE) and its Hanford contractors. Program services include administrating the Hanford personnel dosimeter processing program and ensuring that the related dosimeter data accurately reflect occupational dose received by Hanford personnel or visitors. Specific chapters of this report deal with the following subjects: personnel dosimetry organizations at Hanford and the associated DOE and contractor exposure guidelines; types, characteristics, and procurement of personnel dosimeters used at Hanford; personnel dosimeter identification, acceptance testing, accountability, and exchange; dosimeter processing and data recording practices; standard sources, calibration factors, and calibration processes (including algorithms) used for calibrating Hanford personnel dosimeters; system operating parameters required for assurance of dosimeter processing quality control; special dose evaluation methods applied for individuals under abnormal circumstances (i.e., lost results, etc.); and methods for evaluating personnel doses from nuclear accidents. 1 ref., 14 figs., 5 tabs.

Fix, J.J.

1990-10-01T23:59:59.000Z

466

Energy Assurance | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProvedDecember 2005DepartmentDecember 2011 EMAB MeetingInformation Center»EnergyAssurance

467

Power Assure | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth'sOklahoma/GeothermalOrangePeru:Job Corp JumpWind TurbinePoulsen Hybrid,Assure

468

Sandia National Laboratories: Energy Assurance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 -the Mid-Infrared0EnergySandiaConsortium forAmericanTribal EnergyEnergy Assurance

469

Safety and quality management and administration Fiscal Year 1995 site support program plan WBS 6.7.2.6  

SciTech Connect (OSTI)

The mission of the Emergency, Safety, and Quality Services (ESQ) management and Program Integration is to provide leadership for the ESQ Department, coordinate business management activities of the ESQ department, and the programs it supports, as well as to plan organize, direct, and control other activities that require department-wide coordination. Primary activities include providing strategic and business planning and reporting support to ESQ management; developing and documenting ESQ management systems and procedures; coordinating ESQ`s self-assessment and Award Fee self evaluation efforts; coordinating the ESQ departments`s communication, total quality, cost savings, and productivity efforts; and tracking ESQ commitments and staffing data. This program element also provides program direction and performance assessment for the ESH&Q division of ICF KH. The ESH&Q Division educates ICF KH management and employees to protect personnel and the environment; identifies, interprets and inspects to requirements; provides administrative and field support; performs final acceptance of construction; assesses effectiveness of ICF KH programs and processes, and performs baseline ESH&Q assessments.

Hagan, J.W.

1994-09-01T23:59:59.000Z

470

The ARRA EAP Energy Assurance Planning Bulletin  

Broader source: Energy.gov (indexed) [DOE]

Efficiency Standards Energy Assurance Success Stories Heber Light & Power Takes Lead on Local EA Planning Upcoming Events NASEONARUC Environmental Protection & Clean, Reliable...

471

Energy Assurance Daily (EAD): July 2012  

Broader source: Energy.gov [DOE]

Energy Assurance Daily provides a summary of public information concerning current energy issues. Published Monday through Friday to inform stakeholders of developments affecting energy systems,...

472

The ARRA EAP Energy Assurance Planning Bulletin  

Broader source: Energy.gov (indexed) [DOE]

of State EA Plans Exercise and Reporting Deadlines Energy Assurance Success Stories West Virginia News from the States California is Top Renewable State Upcoming Events NMU...

473

Energy Assurance Daily (EAD): April 2012  

Broader source: Energy.gov [DOE]

Energy Assurance Daily provides a summary of public information concerning current energy issues. Published Monday through Friday to inform stakeholders of developments affecting energy systems,...

474

Energy Assurance Daily (EAD): June 2012  

Broader source: Energy.gov [DOE]

Energy Assurance Daily provides a summary of public information concerning current energy issues. Published Monday through Friday to inform stakeholders of developments affecting energy systems,...

475

BUILDING VENTILATION AND INDOOR AIR QUALITY PROGRAM. CHAPTER FROM ENERGY AND ENVIRONMENT DIVISION ANNUAL REPORT 1978  

E-Print Network [OSTI]

Critical Analysis of Nitrogen Dioxide Air Quality Standards.22 Gaseous Emissions: Nitrogen Dioxide, Carbon Monoxide,3- 4 GASEOUS EMISSIONS: NITROGEN DIOXIDE, CARBON MONOXIDE,

Cairns, Elton J.

2011-01-01T23:59:59.000Z

476

EIS-0127: New Energy-Efficient Homes Programs, Assessing Indoor Air Quality Options  

Broader source: Energy.gov [DOE]

The Bonneville Power Administration developed this EIS to explore whether different building techniques will control indoor air quality and still maintain cost-effective energy savings.

477

Quality Counts Certificate  

E-Print Network [OSTI]

This certificate accompanies the Quality Counts program. 1 page. It comes in packages of 25 certificates....

Chilek, Kevin

2007-01-31T23:59:59.000Z

478

Final project report on arsenic biogeochemistry in the Clinch River and Watts Bar Reservoir: Volume 2, Quality assurance/quality control summary report for arsenic biogeochemistry in the Clinch River and Watts Bar Reservoir. Environmental Restoration Program  

SciTech Connect (OSTI)

Arsenic contamination was studied in the Clinch River/Watts Bar Reservoir (CR/WBR) system downstream from the US Department of Energy`s Oak Ridge Reservation (ORR). Arsenic is of particular interest and concern because (1) it occurs commonly in coal-bearing rock and waste products such as fly ash associated with the burning of coal, (2) it is classified as a Class A carcinogen by the US Environmental Protection Agency, and (3) disposal of fly ash, both on and off the ORR, may have contaminated surface water and sediments in the Clinch River and Watts Bar Reservoir. The present study dffers from previous reports on arsenic concentrations in the CR/WBR system in the use of much more sensitive and precise processing and analytical techniques to measure arsenic species (arsenate, arsenite, and organic arsenic) at levels well below the ecological and human health risk screening criteria. The absolute detection limits using these techniques are approximately 20 to 40 pmol/L or 0.0015 to 0.003 {mu}g/L.

Newman, K.A.; Ford, C.J.; Byrd, J.T.

1995-04-01T23:59:59.000Z

479

Tank waste remediation system characterization project quality policies  

SciTech Connect (OSTI)

This quality plan describes the system used by Characterization Project management to achieve quality. This plan is comprised of eleven quality policies which, when taken together, form a management system deployed to achieve quality. This quality management system is based on the customer`s quality requirements known as the `RULE`, 10 CFR 830.120, Quality Assurance.

Board, D.C.

1997-09-24T23:59:59.000Z

480

Tank waste remediation system characterization project quality policies  

SciTech Connect (OSTI)

This quality plan describes the system used by Characterization Project management to achieve quality. This plan is comprised on eleven quality policies which, when taken together, form a management system deployed to achieve quality. This quality management system is based on the customer`s quality requirements known as the `RULE`, 10 CFR 830.120, Quality Assurance.

Trible, T.C., Westinghouse Hanford

1996-07-31T23:59:59.000Z

Note: This page contains sample records for the topic "quality assurance program" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Elements of a nuclear criticality safety program  

SciTech Connect (OSTI)

Nuclear criticality safety programs throughout the United States are quite successful, as compared with other safety disciplines, at protecting life and property, especially when regarded as a developing safety function with no historical perspective for the cause and effect of process nuclear criticality accidents before 1943. The programs evolved through self-imposed and regulatory-imposed incentives. They are the products of conscientious individuals, supportive corporations, obliged regulators, and intervenors (political, public, and private). The maturing of nuclear criticality safety programs throughout the United States has been spasmodic, with stability provided by the volunteer standards efforts within the American Nuclear Society. This presentation provides the status, relative to current needs, for nuclear criticality safety program elements that address organization of and assignments for nuclear criticality safety program responsibilities; personnel qualifications; and analytical capabilities for the technical definition of critical, subcritical, safety and operating limits, and program quality assurance.

Hopper, C.M.

1995-07-01T23:59:59.000Z

482

OIA: Office of Contract Assurance: Assurance Systems: Cyber Security...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

(QA) It is the policy of the Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) to carry out all activities in a reliable, safe and quality manner. To help fulfill...

483

Maintaining Quality in a Decommissioning Environment  

SciTech Connect (OSTI)

The decommissioning of AECL's Whiteshell Laboratories is Canada's largest nuclear decommissioning project to date. This research laboratory has operated for forty years since it was set up in 1963 in eastern Manitoba as the Whiteshell Nuclear Research Establishment, complete with 60 MW(Th) test reactor, hot cells, particle accelerators, and multiple large-scale research programs. Returning the site to almost complete green state will require several decades of steady work in combination with periods of storage-with-surveillance. In this paper our approach to maintaining quality during the long decommissioning period is explained. In this context, 'quality' includes both regulatory aspects (compliance with required standards) and business aspects (meeting the customers' needs and exceeding their expectations). Both aspects are discussed, including examples and lessons learned. The five years of development and implementation of a quality assurance program for decommissioning the WL site have led to a number of lessons learned. Many of these are also relevant to other decommissioning projects, in Canada and elsewhere: - Early discussions with the regulator can save time and effort later in the process; - An iterative process in developing documentation allows for steady improvements and input throughout the process; - Consistent 2-way communication with staff regarding the benefits of a quality program assists greatly in adoption of the philosophy and procedures; - Top-level management must lead in promoting quality; - Field trials of procedures ('beta testing') ensures they are easy to use as well as useful. Success in decommissioning the Whiteshell Laboratories depends on the successful implementation of a rigorous quality program. This will help to ensure both safety and efficiency of all activities on site, from planning through execution and reporting. The many aspects of maintaining this program will continue to occupy quality practitioners in AECL, reaping steady benefits to AECL and to its customers, the people of Canada.

Attas, Michael [Atomic Energy of Canada Limited, Whiteshell Laboratories, Pinawa, Manitoba, R0E 1L0 (Canada)

2008-01-15T23:59:59.000Z

484

DATA MONITORING AND ANALYSIS PROGRAM MANUAL  

E-Print Network [OSTI]

Requirements" · DOE Order 414.1C, Quality Assurance · DOE O 5480.19, Conduct of Operations Requirements for DOE

485

Using Formal Models to Objectively Judge Quality of Multi-Threaded Programs in Empirical Studies  

E-Print Network [OSTI]

properties in the Finite State Processes (FSP) notation and use the Labeled Transition System Analyzer (LTSA-1-60558-025-8/08/05 ...$5.00. lyzer (LTSA), quality assessment of code, synchronization analy- sis 1. Introduction

Stirewalt, Kurt

486

Standards, Guidance and Practices for Improved Data Quality  

SciTech Connect (OSTI)

Since the mid 1980s, the Idaho National Laboratory (INL) has been involved with numerous projects to collect operational reactor data, develop data tools, and trend and analyze that data for the U.S. Nuclear Regulatory Commission (NRC). Because the data are used in subsequent risk analyses, the NRC must have confidence in the quality of the data delivered. The NRC tasked the INL to establish a comprehensive data quality assurance program. A key element of that effort was to establish a set of requirements based on industry and government standards, guidance and good practices. This paper discusses where these were found, the process of extracting the requirements and recommendations from the source materials, and the consolidation of them into a concise set of 22 standards, guidance and practices for technical data quality. While this set was created specifically for the data programs within the NRC’s Office of Research, they have broad application to many high-technology industries.

Martin B. Sattison

2010-06-01T23:59:59.000Z

487

Efficacy of an integrated continuing medical education (CME) and quality improvement (QI) program on radiation oncologist (RO) clinical practice  

SciTech Connect (OSTI)

Purpose: There has been little radiation oncologist (RO)-specific research in continuing medical education (CME) or quality improvement (QI) program efficacy. Our aim was to evaluate a CME/QI program for changes in RO behavior, performance, and adherence to department protocols/studies over the first 12 months of the program. Methods and Materials: The CME/QI program combined chart audit with feedback (C-AWF), simulation review AWF (SR-AWF), reminder checklists, and targeted CME tutorials. Between April 2003 and March 2004, management of 75 patients was evaluated by chart audit with feedback (C-AWF) and 178 patients via simulation review audit (SR-AWF) using a validated instrument. Scores were presented, and case management was discussed with individualized educational feedback. RO behavior and performance was compared over the first year of the program. Results: Comparing the first and second 6 months, there was a significant improvement in mean behavior (12.7-13.6 of 14, p = 0.0005) and RO performance (7.6-7.9 of 8, p = 0.018) scores. Protocol/study adherence significantly improved from 90.3% to 96.6% (p = 0.005). A total of 50 actions were generated, including the identification of learning needs to direct CME tutorials, the systematic change of suboptimal RO practice, and the alteration of deficient management of 3% of patients audited during the program. Conclusion: An integrated CME/QI program combining C-AWF, SR-AWF, QI reminders, and targeted CME tutorials effectively improved targeted RO behavior and performance over a 12-month period. There was a corresponding increase in departmental protocol and study adherence.

Leong, Cheng Nang [Department of Radiation Oncology, Cancer Institute, National University Hospital (Singapore) and Department of Radiation Oncology, Cancer Institute, Tan Tock Seng Hospital (Singapore)]. E-mail: Cheng_Nang_Leong@mail.nhg.com.sg; Shakespeare, Thomas Philip [Department of Radiation Oncology, Cancer Institute, National University Hospital (Singapore); North Coast Cancer Institute, Coffs Harbour (Australia); Mukherjee, Rahul K. [Department of Radiation Oncology, Cancer Institute, National University Hospital (Singapore); Department of Radiation Oncology, Cancer Institute, Tan Tock Seng Hospital (Singapore); Back, Michael F. [Department of Radiation Oncology, Cancer Institute, National University Hospital (Singapore); Department of Radiation Oncology, Cancer Institute, Tan Tock Seng Hospital (Singapore); Lee, Khai Mun [Department of Radiation Oncology, Cancer Institute, National University Hospital (Singapore); Department of Radiation Oncology, Cancer Institute, Tan Tock Seng Hospital (Singapore); Lu, Jiade Jay [Department of Radiation Oncology, Cancer Institute, National University Hospital (Singapore); Department of Radiation Oncology, Cancer Institute, Tan Tock Seng Hospital (Singapore); Wynne, Christopher J. [Department of Radiation Oncology, Cancer Institute, National University Hospital (Singapore); Lim, Keith [Department of Radiation Oncology, The Cancer Institute, National University Hospital (Singapore); Tang, Johann [Department of Radiation Oncology, Cancer Institute, National University Hospital (Singapore); Department of Radiation Oncology, Cancer Institute, Tan Tock Seng Hospital (Singapore); Zhang Xiaojian [Department of Radiation Oncology, Cancer Hospital, Fudan Hospital, Shanghai (China)

2006-12-01T23:59:59.000Z

488

RESULTS OF THE EXCRETA BIOASSAY QUALITY CONTROL PROGRAM FOR APRIL 1, 2011 THROUGH MARCH 31, 2012  

SciTech Connect (OSTI)

The performance statistics for the Hanford excreta radiobioassay program are presented and discussed. The performance period covers the second contract year of Contract 112512 - April 2011 to March 2012.

Antonio, Cheryl L.; MacLellan, Jay A.

2012-10-31T23:59:59.000Z

489

Project Hanford management contract quality improvement project management plan  

SciTech Connect (OSTI)

On July 13, 1998, the U.S. Department of Energy, Richland Operations Office (DOE-RL) Manager transmitted a letter to Fluor Daniel Hanford, Inc. (FDH) describing several DOE-RL identified failed opportunities for FDH to improve the Quality Assurance (QA) Program and its implementation. In addition, DOE-RL identified specific Quality Program performance deficiencies. FDH was requested to establish a periodic reporting mechanism for the corrective action program. In a July 17, 1998 response to DOE-RL, FDH agreed with the DOE concerns and committed to perform a comprehensive review of the Project Hanford Management Contract (PHMC) QA Program during July and August, 1998. As a result, the Project Hanford Management Contract Quality Improvement Plan (QIP) (FDH-3508) was issued on October 21, 1998. The plan identified corrective actions based upon the results of an in-depth Quality Program Assessment. Immediately following the scheduled October 22, 1998, DOE Office of Enforcement and Investigation (EH-10) Enforcement Conference, FDH initiated efforts to effectively implement the QIP corrective actions. A Quality Improvement Project (QI Project) leadership team was assembled to prepare a Project Management Plan for this project. The management plan was specifically designed to engage a core team and the support of representatives from FDH and the major subcontractors (MSCs) to implement the QIP initiatives; identify, correct, and provide feedback as to the root cause for deficiency; and close out the corrective actions. The QI Project will manage and communicate progress of the process.

ADAMS, D.E.

1999-03-25T23:59:59.000Z

490

Designing and Implementing Effective Performance Assurance Plans  

Broader source: Energy.gov [DOE]

Presentation—given at the Fall 2012 Federal Utility Partnership Working Group (FUPWG) meeting— covers performance assurance planning and process, including performance-based contracts, and measurement and verification protocols.

491

Groundwater quality monitoring well installation for Waste Area Grouping at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program  

SciTech Connect (OSTI)

This report documents the drilling and installation of 18 groundwater quality monitoring (GQM) wells on the perimeter of Waste Area Grouping (WAG) 11. WAG 11 (White Wing Scrap Yard) is located on the west end of East Fork Ridge between White Wing Road and the Oak Ridge Turnpike. The scrap yard is approximately 25 acres in size. The wells at WAG 11 were drilled and developed between January 1990 and October 1990. These wells were installed to characterize and assess the WAG in accordance with applicable Department of Energy, state, and Environmental Protection Agency regulatory requirements. The wells at WAG 11 were drilled with auger or air rotary rigs. Depending on the hydrogeologic conditions present at each proposed well location, one of four basic installation methods was utilized. Detailed procedures for well construction were specified by the Engineering Division to ensure that the wells would provide water samples representative of the aquifer. To ensure conformance with the specifications, Energy Systems Construction Engineering and ERCE provided continuous oversight of field activities. The purpose of the well installation program was to install GQM wells for groundwater characterization at WAG 11. Data packages produced during installation activities by the ERCE hydrogeologists are an important product of the program. These packages document the well drilling, installation, and development activities and provide valuable data for well sampling and WAG characterization. The forms contained in the packages include predrilling and postdrilling checklists, drilling and construction logs, development and hydraulic conductivity records, and quality control-related documents.

Mortimore, J.A.; Lee, T.A.

1994-09-01T23:59:59.000Z

492

Energy Assurance Daily (EAD): January - March 2012 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana.Program - LibbyofThisStatementNOTElectricityofWaterMapProductivityAssurance

493

The role of combustion diagnostics in coal quality impact and NO{sub x} emissions field test programs  

SciTech Connect (OSTI)

Many utilities are examining low sulfur coal or coal blending options to comply with the Clean Air Act Amendment SO{sub 2} emission limits. Test burns have been conducted with the more promising candidate coals to characterize the potential impact of a change in coal quality on boiler operation and performance. Utilities are also under considerable pressure to evaluate NO{sub x} control options and develop a compliance plan to meet strict NO{sub x} regulations, particularly in high population density metropolitan areas on the Eastern seaboard. Field test programs have been conducted to characterize baseline NO{sub x} emissions, evaluate the NO{sub x} reduction potential of combustion modifications, and assess the potential of combustion tuning as an alternative to burner replacement. Coal quality impacts (slagging, fouling, heat absorption, ash removal) and NO{sub x} emissions are both strongly dependent upon the coal combustion process and site-specific boiler firing practices. Non-uniform combustion in the burner region can result in adverse ash deposition characteristics, carbon carryover problems, high furnace exit gas temperatures, and NO{sub x}emission characteristics that are not representative of the coal or the combustion equipment. Advanced combustion diagnostic test procedures have been developed to evaluate and improve burner zone combustion uniformity, even in cases where the coal flow to the individual burners may be non-uniform. The paper outlines a very practical solving approach to identifying combustion related problems that affect ash deposition and NO{sub x} emissions. The benefits of using advanced diagnostic instrumentation to identify problems and tune combustion conditions is illustrated using test data from recent quality field test programs.

Thompson, R.E. [Fossil Energy Research Corp., Laguna Hills, CA (United States); Dyas, B. [New England Power Company, Westborough, MA (United States)

1995-03-01T23:59:59.000Z

494

Technical resource document for assured thermal processing of wastes  

SciTech Connect (OSTI)

This document is a concise compendium of resource material covering assured thermal processing of wastes (ATPW), an area in which Sandia aims to develop a large program. The ATPW program at Sandia is examining a wide variety of waste streams and thermal processes. Waste streams under consideration include municipal, chemical, medical, and mixed wastes. Thermal processes under consideration range from various incineration technologies to non-incineration processes such as supercritical water oxidation or molten metal technologies. Each of the chapters describes the element covered, discusses issues associated with its further development and/or utilization, presents Sandia capabilities that address these issues, and indicates important connections to other ATPW elements. The division of the field into elements was driven by the team`s desire to emphasize areas where Sandia`s capabilities can lead to major advances and is therefore somewhat unconventional. The report will be valuable to Sandians involved in further ATPW program development.

Farrow, R.L.; Fisk, G.A.; Hartwig, C.M.; Hurt, R.H.; Ringland, J.T.; Swansiger, W.A.

1994-06-01T23:59:59.000Z

495

Playing it safe: Program improves quality of athletic fields and parks  

E-Print Network [OSTI]

. Who knew that water conservation and athletes? safety were interconnected? Since #26;#19;#19;#21;, the Sports Athletic Field Education program (SAFE) has been evaluating athletic #18;elds and parks across Texas to determine ways to make them...;#19;#19;#21; with the help of Ron Woolley, now regional program director of Agriculture and Natural Resources for AgriLife Extension, said Dr. James McAfee, associate professor and Extension turfgrass specialist at the Texas AgriLife Research and Extension Center...

Orth, Melanie

2011-01-01T23:59:59.000Z

496

What is the VITAL-EQA Program? The maintenance of high quality laboratories  

E-Print Network [OSTI]

are as follows: · Build laboratory capacity through technical support, training, and technology transfer IMMPaCt program (International Micronutrient Malnutrition Prevention and Control Team). Through IMMPa for biochemical indicators for B-vitamins, CRP, iron, and vitamin A. #12;International Activities of the Global

497

Unit 10: Software Quality To introduce software quality management and  

E-Print Network [OSTI]

. ¥ ISO 9001 Quality Systems - Model for Quality Assurance in Design/Development, Production, Installation intervals by management to ensure its continuing suitability, effectiveness and conformance with ISO 9001 with particular reference to the requirements of ISO 9000 and associated standards. Ð To introduce QFD

Finkelstein, Anthony

498

Montana Air Quality Program Laws & Rules Webpage | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to:46 -Energieprojekte3 Climate Zone Subtype A. PlacesEnergyProgram Laws & Rules

499

Quality assurance flood source and method of making  

DOE Patents [OSTI]

Disclosed is a is an improved flood source, and method of making the same, which emits an evenly distributed flow of energy from a gamma emitting radionuclide dispersed throughout the volume of the flood source. The flood source is formed by filling a bottom pan with a mix of epoxy resin with cobalt-57, preferably at 10 to 20 millicuries and then adding a hardener. The pan is secured to a flat, level surface to prevent the pan from warping and to act as a heat sink for removal of heat from the pan during the curing of the resin-hardener mixture.

Fisher, Darrell R [Richland, WA; Alexander, David L [West Richland, WA; Satz, Stanley [Surfside, FL

2002-12-03T23:59:59.000Z

500

Giant Leap Forward Toward Quality Assurance of PV Modules (Presentation)  

SciTech Connect (OSTI)

The presentation describes the composition of and motivation for the International PV QA Task Force, then describes the presentations and discussion that occurred at the workshop on Feb. 29th, 2012.

Kurtz, S.; Wohlgemuth, J.; Sample, T.; Yamamichi, M.

2012-03-01T23:59:59.000Z