Powered by Deep Web Technologies
Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

The Reliability Investigation on ACSR Splice Connector Systems Used in Overhead Power transmission Lines  

SciTech Connect

Due to material discontinuity and inherited forming mechanism from a crimped-type splice connector, the associated conductor-connector system is highly sensitive to system components aging, especially during high-temperature operations. Furthermore, due to the increase in power demand and limited investment in new infrastructure, existing overhead power transmission lines often need to operate at temperatures higher than the original designed values. This has led to the accelerated aging and degradation of conductor-connector systems. The implications of connector aging are two-fold: (1) significant increase in resistivity of the splice connector and (2) significant reduction in the connector clamping strength. Therefore, splice connectors are one of the weakest links in the electric power transmission infrastructure. In this paper we will discuss the reliability of splice connector systems, including both single stage and two stage splice connectors, used in ACSR conductor of transmission lines under high temperature operations.

Wang, Jy-An John [ORNL] [ORNL; Jiang, Hao [ORNL] [ORNL; Ren, Fei [ORNL] [ORNL

2012-01-01T23:59:59.000Z

2

Medium Voltage Overhead Power-line Broadband Communications; Transmission Capacity and Electromagnetic Interference  

E-Print Network (OSTI)

and Electromagnetic Interference P. Amirshahi and M. Kavehrad (FIEEE) The Pennsylvania State University, Department distribution networks for broadband power-line communications applications. Electromagnetic interference

Kavehrad, Mohsen

3

Reliability of lightning resistant overhead distribution lines  

SciTech Connect

An assessment of the 32 year historical reliability of the 13.8 kV electrical distribution system at the Oak Ridge National Laboratory (ORNL) in Tennessee has yielded several conclusions useful In the planning of Industrial power Systems. The system configuration at ORNL has essentially remained unchanged in the last 32 years which allows a meaningful comparison of reliability trends for the plant`s eight overhead distribution lines, two of which were built in the 1960`s with lightning resistant construction techniques. Meticulous records indicating the cause, duration, and location of 135 electric outages in the plant`s distribution system have allowed a reliability assessment to be performed. The assessment clearly shows how differences in voltage construction class, length, age, and maximum elevation above a reference elevation influence the reliability of overhead power distribution lines. Comparisons are also made between the ORNL historical data and predicted failure rates from ANSI and IEEE industry surveys.

Tolbert, L.M.; Cleveland, J.T.; Degenhardt, L.J.

1995-04-01T23:59:59.000Z

4

Nondestructive Testing of Overhead Transmission Lines: Numerical and Experimental Investigation  

E-Print Network (OSTI)

Overhead transmission lines are periodically inspected using both on-ground and helicopter-aided visual inspection. Factors including sun glare, cloud cover, close proximity to power lines and the rapidly changing visual circumstances make airborne...

Kulkarni, Salil Subhash

2011-02-22T23:59:59.000Z

5

Overhead electric power transmission line jumpering system for bundles of five or more subconductors  

DOE Patents (OSTI)

Jumpering of electric power transmission lines at a dead end tower. Two transmission line conductor bundles each contain five or more spaced apart subconductors (5) arranged in the shape of a cylinder having a circular cross section. The ends of each bundle of subconductors are attached with insulators to a dead end tower (1). Jumpering allows the electric current to flow between the two bundles of subconductors using jumper buses, internal jumper conductors, and external jumper conductors. One or more current collecting jumper buses (37) are located inside each bundle of subconductors with each jumper bus being attached to the end of a subconductor. Small-diameter internal jumper conductors (33) are located in the inherently electrically shielded area inside each bundle of subconductors with each subconductor (except ones having an attached jumper bus) having one internal jumper conductor connected between that subconductor's end and a jumper bus. Large-diameter external jumper conductors (9) are located outside each bundle of subconductors with one or more external jumper conductors being connected between the jumper buses in one bundle of subconductors and the jumper buses in the other bundle.

Winkelman, Paul F. (Beaverton, OR)

1982-01-01T23:59:59.000Z

6

POWER-EFFICIENT OFDM WITH REDUCED COMPLEXITY AND FEEDBACK OVERHEAD  

E-Print Network (OSTI)

to the transmitter. Our design exploits the correlation among sub-carriers in order to re- duce feedback overheadPOWER-EFFICIENT OFDM WITH REDUCED COMPLEXITY AND FEEDBACK OVERHEAD Antonio G. Marques Dept. of TSC subscriber lines (DSL), digital audio and video broadcasting (DAB/DVB) standards and wireless local area

Marques, Antonio Garcia

7

System Design Considerations for High data Rate Communications Over Multi-wire Overhead Power-  

E-Print Network (OSTI)

System Design Considerations for High data Rate Communications Over Multi-wire Overhead Power communications, multi-wire overhead lines, capacity, OFDM, coding. I. INTRODUCTION The increasing interest, and severe narrowband interference [1]. The channel characteristics of medium voltage overhead power-line

Kavehrad, Mohsen

8

High voltage overhead long transmission line design and fault analysis.  

E-Print Network (OSTI)

??The goal of this project is to design a reliable high voltage overhead long transmission line that satisfies specific design criteria including voltage regulation, efficiency, (more)

Elzain, Mohamed Ali

2011-01-01T23:59:59.000Z

9

Objective determination of optimal power line designs.  

E-Print Network (OSTI)

??Includes abstract. The thesis investigated the possibility of overhead power line designs being decided by using an objective rather thana subjective method. Power lines are (more)

Stephen, Robert G.

2010-01-01T23:59:59.000Z

10

Assessment and analysis of indirect lightning performance of overhead lines  

Science Journals Connector (OSTI)

Abstract This paper presents an efficient method for the assessment of the indirect lightning performance of overhead power lines and analyses the influence of some relevant parameters on the flashover rate. The method is based on a formula to calculate the peak value of lightning-induced voltages in overhead lines over a lossy ground, which considers the front-time of the channel-base current. The results of the method are validated by comparison with results available in the literature. The method is then used to investigate the effect of subsequent strokes on the line flashover rate, leading to the conclusion that their contribution is negligible, as long as no correlation is assumed between front-time and peak value of the strokes (first and subsequent). In the following, the method is used to analyze the influence of some parameters on the lightning performance of overhead lines. The results show that the stroke current front-time influence decreases as the soil resistivity increases, and that a higher front-time leads to a lower flashover rate. It is shown that the use of a fixed front-time T=5.63?s for the first strokes leads to results that match well the results obtained from Cigrs front-time probabilistic distribution. Regarding the return stroke velocity, the results show that, for soils with resistivity higher than 100?m, the flashover rate increases as the return stroke velocity increases. The results also show that a relative velocity vr=0.4 leads to flashover rates that match well the results obtained considering some correlations between return stroke velocity and peak current proposed in the literature. The influence of the correlation between current peak value and front-time for first strokes is also analyzed and it is shown that the correlation reduces the flashover rate. It is also shown that considering this correlation for first strokes and not for subsequent strokes increases the contribution of the latter to the flashover rate, especially for good conducting soils.

J.O.S. Paulino; C.F. Barbosa; I.J.S. Lopes; W.C. Boaventura

2015-01-01T23:59:59.000Z

11

Analysis of Lightning-induced Voltages in Overhead Transmission Lines  

Science Journals Connector (OSTI)

Abstract In this work we study the coupling of lightning induced voltages in Overhead Transmission Lines .The study is led directly in the time domain with hold in account the effect of a finite conductivity of the soil. After discretization by the method so-called FDTD (Finite Difference Time Domain) of the lines equations excited by a lightning wave and the application in every node of the network in current and voltage, we deduct a equations system, of which the resolution permits us to deduct the induced electric quantities in every node of the network. In order to confirm our theoretical work, we present a set of applications that allows validating this study.

Mostefa. Boumaiza; Djamel. Labed

2014-01-01T23:59:59.000Z

12

Design of overhead transmission lines subject to localized high intensity wind.  

E-Print Network (OSTI)

??Wind loading considered in the design of overhead transmission lines is based on extreme values of synoptic wind, i.e. boundary layer wind originating from largescale (more)

Langlois, Sbastien, 1981-

2007-01-01T23:59:59.000Z

13

E-Print Network 3.0 - aerial transmission lines Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

Overhead Power-line Broadband Communications; Transmission Capacity and Electromagnetic Interference Summary: Medium Voltage Overhead Power-line Broadband Communications;...

14

A new expression for the ground transient resistance matrix elements of multiconductor overhead transmission lines  

E-Print Network (OSTI)

transmission lines F. Rachidi a, *, S.L. Loyka b , C.A. Nucci c , M. Ianoz a a Swiss Federal Institute The ground impedance matrix elements of a multiconductor overhead transmission line do not have analytical-singular, and which describe, within the limits of transmission line theory, both the early-time and late

Loyka, Sergey

15

Increasing the reliability of the shutdown of 500 - 750-kV overhead lines equipped with shunt reactors in an unsuccessful three-phase automatic repeated closure cycle  

SciTech Connect

The reasons for circuit-breaker failures during repeated disconnection of 500 - 750 kV overhead lines with shunt reactors in a cycle of unsuccessful three-phase automatic reconnection (TARC) are analyzed. Recommendations are made for increasing the operating reliability of power transmission lines with shunt reactors when there is unsuccessful reconnection.

Kuz'micheva, K. I.; Merzlyakov, A. S.; Fokin, G. G. [JSC 'R and D Center at Federal Grid Company of the United Power System' (Russian Federation)

2013-05-15T23:59:59.000Z

16

Meteorological conditions associated with the full-span galloping oscillations of overhead transmission lines  

E-Print Network (OSTI)

transmission lines J. C.R. Hunt, M.A., Ph.D., A.F.I.M.A., and M.D. Rowbottom,B.Sc., PhJD., A.F.I.M.A. Indexing transmission lines over a 7-year period have been correlated in the form of histograms of number of faults-span galloping oscillations of ice-accreted bundled overhead transmission lines. The main assumption made

Hunt, Julian

17

IMPEE PhD Opportunity Project title: LightFoot PhD A PhD Investigation Lightning Protection of HV Overhead Lines with Non-Ideal  

E-Print Network (OSTI)

to simulate this behaviour. This is to provide guidance to overhead line design engineers on lightening Overhead Lines with Non-Ideal Tower Footing Resistance Supervisor(s): Dr Jonathan Swingler j.swingler@hw.ac.uk Abstract LightFoot PhD ­ A PhD Investigation Lightning Protection of HV Overhead Lines with Non-Ideal Tower

Greenaway, Alan

18

Monitoring the magnetic field in houses under 50 Hz high-voltage overhead transmission lines  

Science Journals Connector (OSTI)

This paper deals with a one-week monitoring of the 50 Hz magnetic field on the ground floor and the first floor of houses under 150, 220 and 380 kV high-voltage overhead three-phase AC transmission lines. The field strength varied with the current intensity, the conductor height, and the storey of the house. Because current intensity varies with time the magnetic field depended on the time of day and the day of the week. The recorded magnetic field ranged from 0.1 T to 4.5 T. The maximum value was at least 20 times weaker than the 100 T exposure level recommended by the guidelines of the International Radiation Protection Association (IRPA) and about 140 times smaller than the 640 T of the European Prestandard (CENELEC). The B-field was, for 99.9% of the measuring time, larger than the 0.2 T cut-off point used to define categories of exposed and unexposed subjects in EMF epidemiological studies and, for 99.3% of the time, was greater than the 0.3 T level used by US private engineering companies as the 'prudent avoidance' exposure limit. The weakest average magnetic field was at least 40 times larger than the 0.02 T background value.

G. Decat; J. Van Tongerloo

1998-01-01T23:59:59.000Z

19

Estimation of the minimum shielding failure flashover current for first and subsequent lightning strokes to overhead transmission lines  

Science Journals Connector (OSTI)

Abstract ATP-EMTP simulations are performed to estimate the minimum shielding failure current causing flashover in overhead transmission lines with operating voltage in the range of 66kV up to 735kV. This critical current, affecting shielding failure flashover rate, is of great importance for assessing the insulation coordination of overhead transmission lines and the connected substations. The minimum shielding failure current causing flashover of line insulation is highly dependent upon insulator string flashover modelling and, also, markedly higher than that calculated according to the relevant IEEE Std 1243-1997 simplified expression. A modification of the latter is suggested by using multiplication factors of 1.5 and 1.65 for first and subsequent lightning strokes, respectively, so as to account for the increased dielectric strength of line insulator strings under non-standard lightning overvoltage surges. Alternatively, the critical currents can be respectively estimated by using average negative breakdown gradients per unit length of insulator string of 680kV/m and 750kV/m. The shielding failure flashover rate of the overhead transmission lines, being greatly influenced by insulator string flashover modelling, is lower than that obtained based on the critical current according to IEEE Std 1243-1997.

Zacharias G. Datsios; Pantelis N. Mikropoulos; Thomas E. Tsovilis

2014-01-01T23:59:59.000Z

20

DAMAGE DETECTION STRATEGIES IN STRUCTURAL HEALTH MONITORING OF OVERHEAD POWER TRANSMISSION SYSTEM  

E-Print Network (OSTI)

part of T&D System that goes from the power plant to substations near demand points. "Distribution" refers to the low voltage part of T&D System that connects substations and consumers' switchgear boxes of 245 HV lines that gives a total of 13 053 km of HV lines distributed on the area of 312 679 km2

Boyer, Edmond

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Design and fault analysis of a 345KV 220 mile overhead transmission line.  

E-Print Network (OSTI)

??Efficient and reliable transmission of bulk power economically benefits both the power company and consumer. This report gives clarification to concept and procedure in design (more)

Clawson, Greg

2012-01-01T23:59:59.000Z

22

New Imperial Valley power line  

SciTech Connect

The Imperial Irrigation District placed its new 104-mile, 230kV transmission line in service in the Imperial Valley on September 14, 1988. The power line, with a rated capacity of 600 megawatts, transmits electricity generated at geothermal power plants. The transmission line was financed by 14 geothermal companies, whose participation was based on the amount of line-capacity they expect to use.

Not Available

1988-12-01T23:59:59.000Z

23

Power Line Calculator for DOS  

SciTech Connect

The Power Line Calculator (PLC) for DOS, version 1.0, is a program that describes the electrical characteristics of a transmission or distribution system given user-defined input. This input may consist of a combination of operating currents and phases, symmetric components, power factor, and real or reactive power. The program also allows the user to designate whether currents are present on the system neutral or in the ground. The PLC assumes that any value entered by the user remains fixed (e.g., phase current, power factor), and for underdetermined systems, basic default assumptions are incorporated: the power factor is held at or near 1.0, the net phase current is kept at or near zero, and the phase conductor currents are kept balanced. The program operates under PC/MS-DOS version 3.3 or later, and the output is available in both tabular and graphic formats.

Silva, J.M. (Enertech Consultants, Campbell, CA (United States))

1992-11-01T23:59:59.000Z

24

Power-aware node-disjoint multipath source routing with low overhead in MANET  

Science Journals Connector (OSTI)

With the advance of wireless communication technologies, small-size and high-performance computing and communication devices like laptops and personal digital assistants are increasingly used in daily life. After the success of second generation mobile system, more interest was started in wireless communications. This interest had led to two types of the wireless networks such as infrastructure wireless network and infrastructure less wireless network, also called mobile ad hoc network (MANET). The research challenges in MANET are related to the routing, security, reliability, scalability, quality of services, internetworking, power consumption and multimedia applications. All the mobile nodes of MANET operate on the battery power; hence power consumption becomes an important issue in MANET. It proposes a power-aware node-disjoint multipath source routing (PNDMSR) for real-time traffic, which balances the node energy utilisation to increase the network lifetime. It takes the network congestion into account to reduce the routing delay across the network, and increases the reliability of the data packets reaching the destination.

M. Bheemalingaiah; M.M. Naidu; D. Sreenivasa Rao; G. Varaprasad

2009-01-01T23:59:59.000Z

25

Power Lines, Cancer, and Fear  

Science Journals Connector (OSTI)

...hypothesized cause was exposure to extremely-low-frequency magnetic fields generated by the electrical current in power lines. Physicists understand these invisible fields well, but most physicians, parents, and patients do not. The movement of any electrical charge creates a magnetic field that can be measured... Over the past 18 years, there has been considerable interest in the possible link between electromagnetic fields and cancer, especially leukemia. The story of this highly publicized research has been marked by mystery, contradiction, and confusion. When ...

Campion E.W.

1997-07-03T23:59:59.000Z

26

Trees and Power Lines: Minimizing Conflicts between Electric Power  

E-Print Network (OSTI)

Trees and Power Lines: Minimizing Conflicts between Electric Power Infrastructure and the Urban Forest By William Brock Most 1 and Steven Weissman 2 March 10, 2012 #12;iiTrees and Power Lines Trees and Power Lines 5 5. Benefits of the Urban Forest 6 a. Carbon Sequestration 6 b. Property Value 6

Kammen, Daniel M.

27

Computing Criticality of Lines in Power Systems  

E-Print Network (OSTI)

Computing Criticality of Lines in Power Systems Ali P?narto identify critical lines, failure of which can causecriticality measure for all lines at a time, as opposed to

Pinar, Ali; Reichert, Adam; Lesieutre, Bernard

2006-01-01T23:59:59.000Z

28

Construction of Central Ferry-Lower Monumental Transmission Line...  

NLE Websites -- All DOE Office Websites (Extended Search)

power line capabilities include transmission, overhead and underground distribution and substation projects. BPA also will be holding two "Meet the Builder" open-houses in late...

29

Intelligent fault diagnosis of power transmission line; -.  

E-Print Network (OSTI)

??This dissertation presents the application of recent intelligent newlinetechniques for fault diagnosis in electrical power transmission line Fault newlinesection identification classification and location are the (more)

Malathi, V

2014-01-01T23:59:59.000Z

30

Ames Lab 101: Next Generation Power Lines  

SciTech Connect

Ames Laboratory scientist Alan Russell discusses the need to develop new power lines that are stronger and more conductive as a way to address the problem of the nation's aging and inadequate power grid.

Russell, Alan

2010-01-01T23:59:59.000Z

31

Street Trees, Overhead Utlitly Distribution, and Physical Infrastructure  

E-Print Network (OSTI)

Street Trees, Overhead Utlitly Distribution, and Physical Infrastructure: Design Implictions of overhead lines for electric transmission to the customer is common in most communities, and is most likely and mission Research and Responsibilities Design considerations Ecological Considerations Budgeting

Schweik, Charles M.

32

Requirements for Power Plant and Power Line Development (Wisconsin) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Requirements for Power Plant and Power Line Development (Wisconsin) Requirements for Power Plant and Power Line Development (Wisconsin) Requirements for Power Plant and Power Line Development (Wisconsin) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Wind Solar Program Info State Wisconsin Program Type Siting and Permitting Provider Public Service Commission of Wisconsin

33

Magnetic field exposure assessment for adult residents of Maine who live near and far away from overhead transmission lines  

SciTech Connect

Sixty-Hz magnetic field exposures were measured for 45 adult residents of Maine. Thirty of the subjects resided near rights-of-way (ROWs) with either 345- and 115-kV transmission lines, or ROWs with only 115-kV transmission lines; fifteen resided far from any transmission lines. Personal exposure data for a single 24-hour period was acquired with the EMDEX. The EMDEX's event-marker button was used to partition exposures into Home and Away components. Also, three area measurements were taken for each subject during the personal exposure measurement period: (1) 24-hr fixed-site bedroom measurement with a second EMDEX; (2) Spot measurements in at least three rooms of every residence; and (3) Spot measurements outside each residence. Residence near transmission lines highly loaded during the measurement period was associated with increased Home and Total exposure relative to a far-away population. Average exposure level while away from home was uniform (at about 2 mG) throughout the study population. On a quantitative level, Home exposure was correlated equivalently with Spot-In (r = .70) and the 24-hr fixed site measurement (r = .68). Correlations of area measurements with Total exposure were weaker because of the dilution effect of Away exposure (r = .64 for Spot-In; r = .61 for 24-h Bedroom). Away and Home exposures were not correlated (r = .14), which reinforced our confidence that the participants used the EMDEX correctly. The data suggest the need for caution before inferences are drawn about total personal exposure from area measurements. The study demonstrates the feasibility of obtaining valid measures of magnetic-field exposure with the personal exposure monitors that have been developed.

Kavet, R.; Silva, J.M.; Thornton, D. (Enertech Consultants, Campbell, CA (United States))

1992-01-01T23:59:59.000Z

34

House Rejects Southern Idaho Power Line  

Science Journals Connector (OSTI)

The House of Representatives has refused to go along with the Bonneville Power Administration's plans to build a power transmission line into southern Idaho, where Monsanto hopes to use part of the power in a planned expansion of its elemental phosphorus ...

1964-06-22T23:59:59.000Z

35

Reducing Execution Overhead in a Data Stream Manager , Uur etintemel  

E-Print Network (OSTI)

is designed to take advantage of our overhead reducing techniques. We also discuss the specific overheads1 Reducing Execution Overhead in a Data Stream Manager Don Carney , Uur ?etintemel , Alex Rasin applications include sensor networks, position tracking, fabrication line management, network management

Cherniack, Mitch

36

Power line communications for smart grid applications  

Science Journals Connector (OSTI)

Power line communication, that is, using the electricity infrastructure for data transmission, is experiencing a renaissance in the context of Smart Grid. Smart Grid objectives include the integration of intermittent renewable energy sources into the ...

Lars Torsten Berger; Andreas Schwager; J. Joaqun Escudero-Garzs

2013-01-01T23:59:59.000Z

37

factsheet - trees and power lines - July 2008  

NLE Websites -- All DOE Office Websites (Extended Search)

Trees and power lines July 2008 This summer, BPA maintenance crews are inspecting and clearing high-growing vegetation from all 8,500- miles (15,000 circuit miles) of our...

38

New live line tester for porcelain suspension insulators on high-voltage power lines  

SciTech Connect

Suspension insulator assemblies known as insulator strings are used in overhead power transmission lines to mechanically support high-voltage conductors while providing adequate insulation to withstand switching and lightning overvoltages. Since the useful life in service of the individual insulator elements making up these strings is hard to predict, they must be verified periodically to insure that adequate line reliability is maintained at all times. Over the years many testing methods have been used for this purpose, each one with its own advantages and disadvantages. Until now at Hydro-Quebec, porcelain insulators had been tested by the buzz method which simply consists of applying a short-circuit to each insulator in a string and listening for a buzz-like sound indicating a good insulator. However, safety considerations that preclude short-circuiting insulators and other disadvantages of that method have led Hydro-Quebec to undertake and complete the development of a new insulator tester. The working principle of this new device is based on the automatic measurement and recording of the electric field along the insulator string which decreases considerably in front of an internally-shorted insulator. The tester is slid along the string while the insulators are counted automatically. The information from tests on up to 200 strings can be stored in the device to be later transferred in a host computer for interpretation and/or permanent storage. The new tester also gives information on voltage distribution along the insulator strings which can be useful for the design of future power transmission lines.

Vaillancourt, G.H.; St-Jean, M. (Hydro-Quebec, Varennes, Quebec (Canada)); Bellerive, J.P. (Hydro-Quebec, Montreal, Quebec (Canada)); Jean, C. (Positron Inc., Montreal, Quebec (Canada))

1994-01-01T23:59:59.000Z

39

Axial power loss along open field lines  

SciTech Connect

Studies are underway to evaluate the linear mirror geometry as a candidate for a high-fluence, neutron irradiation facility. This steady-state, low-Q design is currently perceived to comprise a two-component plasma driven by neutral beams with mirror confinement of the hot ions and with no electrostatic axial reduction in the warm ion end losses. Warm-ion fueling and end-wall power density will require substantial cold plasma exterior to the mirror cell and neutral gas near the end wall. In this paper, we evaluate to what extent the loss power parallel to the axial magnetic field along open field lines is a function of the escaping plasma and end-wall parameters. By allowing the source power to depend directly on the plasma density and electron temperature, several new conclusions may be pertinent to closed field-line geometries with open field-line divertors.

Correll, D.L.

1987-08-01T23:59:59.000Z

40

SMB Host Processor Overhead  

NLE Websites -- All DOE Office Websites (Extended Search)

SMB SMB SMB Description There are two benchmarks included here. The msg_rate test measures the sustained MPI message rate using a communication pattern found in many real applications. For a complete explanation of the routine refer to http://www.cs.sandia.gov/smb/msgrate.html. The mpi_overhead test uses a post-work-wait method using MPI non-blocking send and receive calls to measure the user level overhead of the respective MPI calls. For a complete explanation of the routine refer to http://www.cs.sandia.gov/smb/overhead.html. Download SMB tar file How to Build The source files are in the src directory, in smb_1.0-1/src/mpi_overhead and smb_1.0-1/src/msgrate. Edit the Makefile for your environment and type 'make.' How to Run The executables run a single message at a time. The "run_script" scripts

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Power Line Calculator for Windows[trademark  

SciTech Connect

The Power Line Calculator (PLC) for Windows [trademark], version 1.0, is a program that describes the electrical characteristics of a transmission or distribution system given user-defined input. This input may consist of a combination of operating currents and phases, symmetric components, power factor, and real or reactive power. The program also allows the user to designate whether currents are present on the system neutral or in the ground. The PLC assumes that any value entered by the user remains fixed (e.g., phase current, power factor), and for underdetermined systems, basic default assumptions are incorporated: the power factor is held at or near 1.0, the net phase current is kept at or near zero, and the phase conductor currents are kept balanced. The program operates through a graphical user interface provided by Microsoft[reg sign] Windows [trademark] (version 3.1 or higher required), and the output is available in both tabular and graphic formats.

Silva, J.M. (Enertech Consultants, Campbell, CA (United States))

1992-12-01T23:59:59.000Z

42

A Bandwidth-Based Power-Aware Routing Protocol with Low Route Discovery Overhead in Mobile Ad hoc Networks  

Science Journals Connector (OSTI)

......protocol, where the power consumed by listening to the transmission of a packet is represented...equipped with the IEEE 802.11b wireless device. Measuring the distance-to-bandwidth...equipped with the IEEE 802.11b wireless device. However, if a specific distance is......

Chuan-Chi Weng; Ching-Wen Chen; Chang-Jung Ku; Shiow-Fen Hwang

2010-09-01T23:59:59.000Z

43

Numerical Optimization Methodology for the Design of Power Equipment  

E-Print Network (OSTI)

health effects from overhead power line conductors [6,7]. Even though no conclusive evidence has been of utility companies have been involved in a redesign of their overhead transmission lines to avoid potentialNumerical Optimization Methodology for the Design of Power Equipment Gaurav Tewari* My M. Hua

Mamishev, Alexander

44

1068 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 25, NO. 4, APRIL 2010 Modeling and Control Design for a Very  

E-Print Network (OSTI)

- generative decentralized sources and the continuous replacement of overhead power lines by subterraneous decentralized sources and the continuous re- placement of overhead power lines by subterraneous distribu- tion1068 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 25, NO. 4, APRIL 2010 Modeling and Control Design

Paderborn, Universität

45

Increasing the Capacity of Existing Power Lines | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Increasing the Capacity of Existing Power Lines Increasing the Capacity of Existing Power Lines The capacity of the grid has been largely unchanged for decades and needs to expand...

46

EIS-0465: Mid-Atlantic Power Pathway Transmission Line Project...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: Mid-Atlantic Power Pathway Transmission Line Project in Maryland and Delaware EIS-0465: Mid-Atlantic Power Pathway Transmission Line Project in Maryland and Delaware March 4,...

47

INVESTIGATION OF A DYNAMIC POWER LINE RATING CONCEPT FOR IMPROVED WIND ENERGY INTEGRATION OVER COMPLEX TERRAIN  

SciTech Connect

Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of power line to be based on real-time conductor temperature dependent on local weather conditions. In current practice overhead power lines are generally given a conservative rating based on worst case weather conditions. Using historical weather data collected over a test bed area, we demonstrate there is often additional transmission capacity not being utilized with the current static rating practice. We investigate a new dynamic line rating methodology using computational fluid dynamics (CFD) to determine wind conditions along transmission lines at dense intervals. Simulated results are used to determine conductor temperature by calculating the transient thermal response of the conductor under variable environmental conditions. In calculating the conductor temperature, we use both a calculation with steady-state assumption and a transient calculation. Under low wind conditions, steady-state assumption predicts higher conductor temperatures that could lead to curtailments, whereas transient calculations produce conductor temperatures that are significantly lower, implying the availability of additional transmission capacity.

Jake P. Gentle; Kurt S Myers; Tyler B Phillips; Inanc Senocak; Phil Anderson

2014-08-01T23:59:59.000Z

48

Green Power Transmission Line Given New Life | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Green Power Transmission Line Given New Life Green Power Transmission Line Given New Life Green Power Transmission Line Given New Life March 11, 2010 - 4:34pm Addthis Poles for the Montana-Alberta Tie Line are unloaded outside Shelby, Mont. | Photo courtesy of Tonbridge Power Poles for the Montana-Alberta Tie Line are unloaded outside Shelby, Mont. | Photo courtesy of Tonbridge Power Stephen Graff Former Writer & editor for Energy Empowers, EERE Thanks to funds from the American Recovery and Reinvestment Act, construction of a green power transmission line stretching from Lethbridge, Alberta in Canada, down to Great Falls, Mont., was put back on track after a bank failure. Currently under construction, the Montana-Alberta Tie Line, which is owned by Toronto-based Tonbridge Power, will connect the electricity markets of

49

Power line harmonic radiation: A systematic study using DEMETER spacecraft  

E-Print Network (OSTI)

Power line harmonic radiation: A systematic study using DEMETER spacecraft F. Nemec a,b,*, O of a systematic survey of Power line harmonic radiation (PLHR) observed by the DEMETER spacecraft. DEME- TER frequency spacing corresponds well to the power system frequency at anticipated source locations. Moreover

Santolik, Ondrej

50

Power line harmonic radiation (PLHR) observed by the DEMETER spacecraft  

E-Print Network (OSTI)

Power line harmonic radiation (PLHR) observed by the DEMETER spacecraft F. Nemec,1,2 O. Santoli´k,3 January 2006; published 22 April 2006. [1] Results of a systematic survey of Power Line Harmonic Radiation from the electric power systems which are magnetically conjugated with the place of observation

Santolik, Ondrej

51

Analysis of magnetic fields produced far from electric power lines  

SciTech Connect

In this paper, the authors develop a simple and general method for analyzing the magnetic fields produced by power lines at far distances, that is, at distances large in comparison to the spacing between the line's phase conductors. Magnetic fields produced far from conventional power lines have remarkably simple properties. The authors present formulae for the fields produced by various conventional and unconventional power line configurations; included are line designs characterized by reduced magnetic-field levels. Errors in the formulae are less than [plus minus]10% at the edge of a typical transmission right-of-way.

Kaune, W.T. (Enertech Consultants Campbell, CA (United States)); Zaffanella, L.E. (High Voltage Transmission Research Center, Lenox, MA (United States))

1992-10-01T23:59:59.000Z

52

EIS-0447: Champlain Hudson Power Express Transmission Line Project, New  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7: Champlain Hudson Power Express Transmission Line Project, 7: Champlain Hudson Power Express Transmission Line Project, New York EIS-0447: Champlain Hudson Power Express Transmission Line Project, New York Summary This EIS evaluates the potential environmental impacts of a DOE proposal to grant a Presidential permit to Champlain Hudson Power Express, Inc., to construct, operate, maintain, and connect a new 1000-megawatt (MW) electric transmission system across the U.S.-Canada border in northeastern New York State. The proposed transmission line would run from the Canadian Province of Quebec to New York City. Public Comment Opportunities None available at this time. Documents Available for Download December 6, 2013 EIS-0447: DOE Notice of Availability of Draft Environmental Impact Statement Champlain Hudson Power Express Transmission Line Project, New York

53

Computing Criticality of Lines in Power Systems Computational Research Div.  

E-Print Network (OSTI)

Computing Criticality of Lines in Power Systems Ali Pinar Computational Research Div. Lawrence critical lines, failure of which can cause severe blackouts. Our method computes criticality measure for all lines at a time, as opposed to detecting a single vulnerability, providing a global view

Geddes, Cameron Guy Robinson

54

Differential GPS Measurement of Overhead Conductor Sag: Software Implementation  

E-Print Network (OSTI)

that can measure the sag of overhead transmission conductors for 69 kV circuits and above. The instrument rating of a transmission-line conductor. The software can be used in an on-line energy manage- ment line near the conductors that effectively measures the electric field. A typical GUI screen is shown

55

Increasing the Capacity of Existing Power Lines  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

works with Idaho Power engineers to train system operators in the use of weather station data and software tools to generate transmission capacity operat- ing limits. The ability...

56

Abstract--Power Line Communications (PLC) is used for information exchange over the lines  

E-Print Network (OSTI)

Abstract-- Power Line Communications (PLC) is used for information exchange over the lines installed for delivering the electrical power. Inhome PLC is a technology which delivers telecom services to every corner of a household through already existing electrical wiring. In recent years, PLC has emerged

Boyer, Edmond

57

EIS-0447: Champlain Hudson Power Express Transmission Line Project, New  

NLE Websites -- All DOE Office Websites (Extended Search)

447: Champlain Hudson Power Express Transmission Line Project, 447: Champlain Hudson Power Express Transmission Line Project, New York EIS-0447: Champlain Hudson Power Express Transmission Line Project, New York Summary This EIS evaluates the environmental impacts of a DOE proposal to grant a Presidential permit to Champlain Hudson Power Express, Inc., to construct, operate, maintain, and connect a new 1000-megawatt (MW) electric transmission system across the U.S.-Canada border in northeastern New York State. The proposed transmission line will run from the Canadian Province of Quebec to New York City. DOE also published a notice correcting the location of the public hearing that was held on November 19, 2013. Public Comment Opportunities As of December 6, 2013 - Comment Period Extended through 1/15/14 Written comments must be received by January 15, 2014. Comments submitted

58

Power Line Plan of Development Outline | Open Energy Information  

Open Energy Info (EERE)

navigation, search OpenEI Reference LibraryAdd to library Legal Document- OtherOther: Power Line Plan of Development OutlineLegal Published NA Year Signed or Took Effect 2005...

59

Living and Working Safely Around High-Voltage Power Lines.  

SciTech Connect

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

United States. Bonneville Power Administration.

2001-06-01T23:59:59.000Z

60

Definition: Transmission Line | Open Energy Information  

Open Energy Info (EERE)

Line Line (Redirected from Definition:Transmission lines) Jump to: navigation, search Dictionary.png Transmission Line A system of structures, wires, insulators and associated hardware that carry electric energy from one point to another in an electric power system. Lines are operated at relatively high voltages varying from 69 kV up to 765 kV, and are capable of transmitting large quantities of electricity over long distances.[1] View on Wikipedia Wikipedia Definition An overhead power line, also known as a "pylon" in some areas, is a structure used in electric power transmission and distribution to transmit electrical energy along large distances. It consists of one or more conductors (most often three or four) suspended by towers or utility poles. Since most of the insulation is provided by air, overhead power lines are

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Rural electrification using overhead HVDC transmission lines.  

E-Print Network (OSTI)

??One of mankinds greatest modern challenges is poverty alleviation. The provision of electricity can greatly assist in this regard. The tapping of small amounts of (more)

Ijumba, Nelson M.

2012-01-01T23:59:59.000Z

62

Definition: Transmission Line | Open Energy Information  

Open Energy Info (EERE)

Transmission Line Transmission Line Jump to: navigation, search Dictionary.png Transmission Line A system of structures, wires, insulators and associated hardware that carry electric energy from one point to another in an electric power system. Lines are operated at relatively high voltages varying from 69 kV up to 765 kV, and are capable of transmitting large quantities of electricity over long distances.[1] View on Wikipedia Wikipedia Definition An overhead power line, also known as a "pylon" in some areas, is a structure used in electric power transmission and distribution to transmit electrical energy along large distances. It consists of one or more conductors (most often three or four) suspended by towers or utility poles. Since most of the insulation is provided by air, overhead power lines are

63

Tucson Electric Power Company Sahuarita-Nogales Transmission Line  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Appendix A Appendix A Consultation Letters Appendix A- Consultation Letters A-1 APPENDIX A CONTENTS A-2 Letter from the State Historic Preservation Office regarding Certificate of Environmental Compatibility Case No. 111: The Proposed Tucson Electric Power Company (TEP) South Substation to Nogales Transmission Line, Pima and Santa Cruz Counties, Arizona A-6 Letter from Tetra Tech, Inc. to El Paso Natural Gas, regarding the Proposed Tucson Electric Power Transmission Line Adjacent to an El Paso Natural Gas Company Pipeline A-8 Letter from Tetra Tech, Inc. to the Drug Enforcement Administration, regarding the Proposed Tucson Electric Power Transmission Line near Nogales, Arizona A-10 Letter from Tetra Tech, Inc. to the U.S. Immigration and Naturalization Service, regarding the

64

Snow accretion on overhead wires  

Science Journals Connector (OSTI)

...Growing process of a snow sleeve for dry-type accretion. Because snow accretion...under sub-freezing temperatures (dry-type snow accretion) will be limited...Mizushima, K. & Kawanishi, S. 1990 Dry type snow accretion on overhead wire...

2000-01-01T23:59:59.000Z

65

Methods of Using Existing Wire Lines (power lines, phone lines, internet lines) for Totally Secure Classical Communication Utilizing Kirchoff's Law and Johnson-like Noise  

E-Print Network (OSTI)

We outline some general solutions to use already existing and currently used wire lines, such as power lines, phone lines, internet lines, etc, for the unconditionally secure communication method based on Kirchoff's Law and Johnson-like Noise (KLJN). Two different methods are shown. One is based on filters used at single wires and the other one utilizes a common mode voltage superimposed on a three-phase powerline.

Laszlo B. Kish

2006-10-02T23:59:59.000Z

66

Vidyut: exploiting power line infrastructure for enterprise wireless networks  

Science Journals Connector (OSTI)

Global synchronization across time and frequency domains significantly benefits wireless communications. Multi-Cell (Network) MIMO, interference alignment solutions, opportunistic routing techniques in ad-hoc networks, OFDMA etc. all necessitate synchronization ... Keywords: frequency synchronization, network mimo, power line communications, time synchronization, wireless networks

Vivek Yenamandra, Kannan Srinivasan

2014-08-01T23:59:59.000Z

67

Public Opinions of Building Additional High-Voltage Electric Power Lines  

E-Print Network (OSTI)

to build new power lines. Residents living in counties with planned routes for new transmission linesPublic Opinions of Building Additional High-Voltage Electric Power Lines A Report to the National-Voltage Electric Power Lines: A Report to the National Science Foundation and the Electric Power Research Center

Tesfatsion, Leigh

68

Power line carrier interference from HVDC converter terminals  

SciTech Connect

Power line carrier (PLC) equipment typically operates in the frequency range from 25 kHz to 300 kHz. Interference studies for HVDC converters usually concentrate on interference from noise sources within this frequency range. However, operating experience at the Sandy Pond converter terminal has indicated that PLC equipment is also susceptible to interference from sources of power system harmonics below the PLC frequency range. Extensive field testing and analytical studies have shown that each PLC circuit has a resonant frequency below the operating frequency. If excited at this resonant frequency, high voltages may exist within the PLC circuit. The resulting saturation of PLC components leads to local generation of radio frequency (RF) noise that interferes with proper operation of PLC circuits. Sources of power system harmonics in the 3-10 kHz range, such as line commutated dc converters, are potential sources of this type of interference.

Tatro, P.J.; Adamson, K.A. (New England Power Service Co., Westborough, MA (United States)); Eitzmann, M.A.; Smead, M. (GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.)

1993-07-01T23:59:59.000Z

69

MECCA: A Robust Low-Overhead PUF Using Embedded Memory Array  

E-Print Network (OSTI)

process variations. Existing PUFs suffer from increased overhead to the original design due using a pro- grammable word line duty cycle controller. Since most modern designs already haveMECCA: A Robust Low-Overhead PUF Using Embedded Memory Array Aswin Raghav Krishna, Seetharam

Bhunia, Swarup

70

Power Development in Turkey  

Science Journals Connector (OSTI)

... 000 kw. steam power station, and the provision of switchgear, overhead lines and three substations for a transmission system about 16 km. in length. Provision is to be made ... will also be provided for stand-by service to the station auxiliaries. Transmission to the substation will be at 66,000 volts, the station output being stepped up to this ...

1940-06-08T23:59:59.000Z

71

Regression-Based RTL Power Modeling ALESSANDRO BOGLIOLO  

E-Print Network (OSTI)

introduce a low overhead on-line characterization method for enhancing the accuracy of off-line estimation is a key feature for synthesis-based design flows. The main challenge in establishing a sound RTL-up off-line characterization of regression-based power macromodels is discussed in detail. Moreover, we

De Micheli, Giovanni

72

Fuel Cell Transit Buses: ThunderPower Bus Evaluation at SunLine...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Transit Buses: ThunderPower Bus Evaluation at SunLine Transit Agency Fuel Cell Transit Buses: ThunderPower Bus Evaluation at SunLine Transit Agency Report details the six-month...

73

3D Reconstruction of 138 KV Power-lines from Airborne LiDAR Data.  

E-Print Network (OSTI)

??Due to infrequent and imprecise maintenance inspection in power-line corridors, accidents can be caused by interferences, for instance, surrounding trees. Transmission power-line inspection conventionally relies (more)

Xiang, Qing

2014-01-01T23:59:59.000Z

74

Number and propagation of line outages in cascading events in electric power transmission systems  

E-Print Network (OSTI)

Number and propagation of line outages in cascading events in electric power transmission systems of transmission lines. We estimate from observed utility data how transmission line outages propagate, and obtain of transmission lines. The multiple mechanisms involved these cascading outages are many and varied, and the power

Dobson, Ian

75

Analysis of the UHV Tie Line Active Power Peak Value of Weak Interconnected Grids Following Power Shortage Disturbance in China Power System  

Science Journals Connector (OSTI)

An ultra high voltage (UHV) AC tie line that connects North China ... peak value of active power oscillation of the UHV AC tie line following power shortage disturbance. ... The typical process of the oscillation...

Feng Hong; Jinfu Chen; Xianzhong Duan

2012-01-01T23:59:59.000Z

76

EIS-0256: Sierra Pacific Power Company Alturas Transmission Line Project (adopted from BLM)  

Energy.gov (U.S. Department of Energy (DOE))

This EIS evaluates the environmental setting and consequences of the construction and operation of the proposal Alturas Transmission Line Project. Sierra Pacific Power Company (SPPCO) has proposed this electric power transmission line to improve the existing operational capacity and reliability of its power transmission system and provide for anticipated growth in demand for electric power.

77

Tucson Electric Power Company Sahuarita-Nogales Transmission Line  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Office of Fossil Energy U.S. Department of Energy 1000 Independence Avenue, S.W. Washington, DC 20585 Cooperating Agencies: U.S. Department of the Interior Bureau of Land Management U.S. Department of Agriculture Forest Service COVER SHEET Responsible Agency: U.S. Department of Energy (DOE), Office of Fossil Energy (FE) Cooperating Agencies: U.S. Department of Agriculture Forest Service (USFS), U.S. Department of the Interior Bureau of Land Management (BLM) Title: Tucson Electric Power Company (TEP) Sahuarita-Nogales Transmission Line Final Environmental Impact Statement (EIS) Location: Pima and Santa Cruz Counties, Arizona Contacts: For additional information on this Final Environmental Impact Statement (EIS), contact: For general information on the DOE

78

Tucson Electric Power Company Sahuarita-Nogales Transmission Line  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SUMMARY Office of Fossil Energy U.S. Department of Energy 1000 Independence Avenue, S.W. Washington, DC 20585 Cooperating Agencies: U.S. Department of the Interior Bureau of Land Management U.S. Department of Agriculture Forest Service Tucson Electric Power Company Sahuarita-Nogales Transmission Line Final Environmental Impact Statement January 2005 DOE/EIS - 0336 BLM Reference No. AZA 31746 SUMMARY Office of Fossil Energy U.S. Department of Energy 1000 Independence Avenue, S.W. Washington, DC 20585 Cooperating Agencies: U.S. Department of the Interior Bureau of Land Management U.S. Department of Agriculture Forest Service COVER SHEET Responsible Agency: U.S. Department of Energy (DOE), Office of Fossil Energy (FE)

79

Power Capture (PowCap) Board for Non Intrusive Load Monitoring and Power Line Communication Exploration and Development  

E-Print Network (OSTI)

PowCap with PLC: Lookingti] Power Line Communication (PLC) Solutions. http://overview.page? DCMP=plc&HQS=plc. [Tsu99] K. Tsuda. Subspace

Balakrishnan, Vikram

2013-01-01T23:59:59.000Z

80

Power line communications (PLC) using impulse ultra wideband (UWB) in a microprocessor had been  

E-Print Network (OSTI)

Abstract Power line communications (PLC) using impulse ultra wideband (UWB) in a microprocessor had data to sensors and for on-line testing. Power line communications (PLC), patented in the early 1920's]. As noted in [1]-[2], PLC in a microprocessor faces a totally different set of technical challenges from

Ha, Dong S.

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Power line harmonic radiation observed by satellite: Properties and propagation through the ionosphere  

E-Print Network (OSTI)

Power line harmonic radiation observed by satellite: Properties and propagation through of power line harmonic radiation events observed by the low-altitude DEMETER spacecraft. Altogether, 88 with the largest intensities often occur off exact multiples of base power system frequency. This can be explained

Santolik, Ondrej

82

EIS-0077-S: Bonneville Power Administration Crow Butte Slough Crossing  

Energy.gov (U.S. Department of Energy (DOE))

The Bonneville Power Administration developed this SEIS to evaluate potential impacts resulting from construction of a 4,700 -foot segment of the Ashe-Slatt transmission line at Crow Butte Slough, overhead on towers on the existing right-of-way. This SEIS is a supplement to DOE/EIS-0077, Ashe-Slatt (Pebble Springs) 500-kilovolt Transmission Line.

83

Power Lines and Crops Can Be Good Neighbors  

SciTech Connect

Two of the Pacific Northwests greatest economic assets are its wealth of agriculture and its clean and reliable electricity fueled largely by hydropower. Sometimes the two intersect. Transmission lines carrying electricity to the regions farms, businesses and homes must, of necessity, span large areas where people grow crops and orchards. To ensure a safe and reliable flow of electricity across these expanses, trees and other vegetation must be managed to certain standards. At the same time, the Bonneville Power Administration which owns and operates three-quarters of the regions high-voltage transmission recognizes the importance of our regions agricultural bounty. We are committed to working with individuals and agricultural communities to facilitate ongoing land-use activities in transmission rights-of-way as long as those uses are compatible with transmission safety and reliability standards. Our goal with vegetation management is to keep you and your property safe while protecting the reliability of our regions electricity system. By working together, BPA and landowners can protect the system and public safety.

none,

2010-08-01T23:59:59.000Z

84

Lovell-Yellowtail transmission line rebuild project, Western Area Power  

NLE Websites -- All DOE Office Websites (Extended Search)

Lovell-Yellowtail Transmission Line Rebuild Project Lovell-Yellowtail Transmission Line Rebuild Project Project overview LVYT-1_158_092512 A contractor crew worked out of the bucket truck, Sept. 25, 2012, to perform dead-ending operations as part of phase 1 of the Lovell-to-Yellowtail transmission line rebuild. (Photo by Bob Kemp) See more photos of phase 1 and 2 constuction on Flickr. Western is rebuilding the Lovell-to-Yellowtail No. 1 and No. 2 115-kV transmission lines. The 94-circuit-miles of lines are located between Lovell, Wyo., and Yellowtail Dam, Mont. The rebuilt transmission lines are needed because the original lines were built by the Bureau of Reclamation in 1956 and 1966. The project will: Ensure reliability and safety of the transmission lines Improve capability to transmit full output from Yellowtail

85

Fuel Cell Transit Buses: ThunderPower Bus Evaluation at SunLine Transit Agency  

Energy.gov (U.S. Department of Energy (DOE))

Report details the six-month evaluation of the ThunderPower hydrogen fuel cell bus demonstrated at SunLine Transit Agency.

86

Monte Carlo estimation of the rates of lightning strikes on power lines  

Science Journals Connector (OSTI)

This paper reports the development of a general method for estimating the rates of lightning strikes on transmission lines using Monte Carlo simulation. Effects of towers, cross-arms, non-level ground, conductor sags and nearby structures are directly represented in the 3-dimension electrogeometric model (EGM). The method developed is a general one that is applicable to any transmission line configuration and is independent of the EGM used. Tedious analytical derivation of more than 100 equations for each configuration as required by analytical methods is avoided altogether. The formulation and a flow chart are detailed in the paper. The shortest distances from the lightning leader tip to individual structures that may be struck are evaluated and then compared with striking distances. The outcome of the comparison identifies the structure which will be struck in each simulation. The exposure area adopted in the simulation is determined on the basis of the transmission line route length and the maximum possible striking distance to ensure that the simulation results in a maximum possible number of strikes on the overhead line. Strokes outside the exposure area will always miss the transmission line and, therefore, have no effects on the results. The method proposed and its software implementation are verified on the basis of results from analytical methods of earlier work, and from field data.

Roger Holt; Tam T. Nguyen

1999-01-01T23:59:59.000Z

87

SunLine Transit Agency Hydrogen-Powered Transit Buses: Third...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

system with a UTC Power PureMotion 1 120 Fuel Cell Power System and ZEBRA batteries for energy storage. SunLine has also been operating a prototype hydrogen hybrid internal...

88

Transmission Line Structure Spotting and Optimization within a Defined Transmission Line Routing Centerline Using Non-Linear Programming Models  

E-Print Network (OSTI)

and optimize structure heights for overhead transmission lines. The modeling tool will address common problems in determining overhead transmission line structure heights and locations. Some of the common problems consist of structure locations often having...

Cockrum, Joshua W.

2010-05-14T23:59:59.000Z

89

Review Article: Power line communication technologies for smart grid applications: A review of advances and challenges  

Science Journals Connector (OSTI)

This paper investigates the use of Power Line Communication (PLC) for Smart Grid (SG) applications. Firstly, an overview is done to define the characteristics of PLC and PLC-based SG applications are addressed to define the compatibility of PLC. Then, ... Keywords: PLC-based smart grid applications, Power line communication, Smart grid

Melike Yigit, V. Cagri Gungor, Gurkan Tuna, Maria Rangoussi, Etimad Fadel

2014-09-01T23:59:59.000Z

90

Electric currents in power transmission line induced by auroral activity  

Science Journals Connector (OSTI)

... the induced current in the Healy-Fairbanks transmission line at one of the transformer sites (substations) in Fairbanks. We show here the simultaneous H component magnetic record and the induced ... approximately the total current flowing in the Healy-Fairbanks line from our measurement at the substation. On the basis of our measurement and the model study, it is indicated that ...

S.-I. AKASOFU; R. P. MERRITT

1979-05-24T23:59:59.000Z

91

Tucson Electric Power Company Sahuarita-Nogales Transmission Line  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

TEP Sahuarita-Nogales Transmission Line Final EIS TEP Sahuarita-Nogales Transmission Line Final EIS 2-4 Figure 2.1-1. Close-up of Alternative Study Corridors Near Sahuarita and Green Valley. Chapter 2- Proposed Action and Alternatives 2-5 Figure 2.1-2. Close-up of Alternative Study Corridors Near Amado. TEP Sahuarita-Nogales Transmission Line Final EIS 2-6 Figure 2.1-3. Close-up of Alternative Study Corridors Near Nogales. TEP Sahuarita-Nogales Transmission Line Final EIS 2-8 Figure 2.1-4. Western Corridor on the Coronado National Forest. Chapter 2-Proposed Action and Alternatives 2-13 Figure 2.1-5. Central Corridor on the Coronado National Forest. Chapter 2-Proposed Action and Alternatives 2-15 Figure 2.1-6. Crossover Corridor on the Coronado National Forest. TEP Sahuarita-Nogales Transmission Line Final EIS

92

Efficient Macromodeling of Power Distribution Planes using Delay Extraction based Transmission Line Representation  

E-Print Network (OSTI)

Efficient Macromodeling of Power Distribution Planes using Delay Extraction based Transmission Line plane structures are based on discretization of the plane into a grid of transmission lines [3]-[6]. Macromodeling the transmission line network using conventional lumped RLGC elements [4]- [6] can provide

Roy, Sourajeet

93

Provisioning of dynamic traffic in mixed-line-rate optical networks with launch power determination  

Science Journals Connector (OSTI)

In mixed-line-rate (MLR) networks, different line rates on different wavelengths can coexist on the same fiber. MLR architectures can be built over transparent optical networks, where the transmitted signals remain in the optical domain along the entire ... Keywords: Dynamic lightpath provisioning, Impairment-aware provisioning, Launch power determination, Mixed-line-rate optical WDM networks

Haydar Cukurtepe, Massimo Tornatore, Aysegul Yayimli, Biswanath Mukherjee

2014-06-01T23:59:59.000Z

94

Investigation of broadband over power line channel capacity of shipboard power system cables for ship communications networks  

E-Print Network (OSTI)

Broadband over Power Line (BPL) technology has garnered significant attention lately due to recent advancements in solid state technologies and channel coding schemes. The successful application of BPL technology for in-home automation...

Akinnikawe, Ayorinde

2009-05-15T23:59:59.000Z

95

Intercontinental cross-linking of power supply - calculating an optimal power line corridor from North Africa to Central Europe  

Science Journals Connector (OSTI)

An oversupply of solar radiation in Northern Africa as well as high energy consumption in the economic centers of Central ... power lines. By this means only, the energy can be economically transferred from the s...

Katrin Walter; Stephan Bosch

2013-07-01T23:59:59.000Z

96

Distribution lines overload control to increase reliability and power loss reduction  

Science Journals Connector (OSTI)

The Indian Power sector is currently undergoing sea change. The pace of economic development along with increasing power demand would require additional generating capacity. Simultaneously increased efficiency in the sector can help in the task of achieving ... Keywords: ASCR conductor, controlling carbon emission, distribution lines, overload, power losses, reliability

Shrirang Karandikar; Ashok Ghatol

2008-04-01T23:59:59.000Z

97

Programme A. Nuclear Power Subprogramme A.4 Technology Development for Advanced Reactor Lines  

E-Print Network (OSTI)

Programme A. Nuclear Power Subprogramme A.4 Technology Development for Advanced Reactor Lines the databases that will be produced in the course of the CRP and make them accessible through the IAEA's nuclear-Electrical Applications of Nuclear Power Project A.5.02: Nuclear hydrogen production CRP Title: Advances in nuclear power

De Cindio, Fiorella

98

Electric Power Lines : Questions and Answers on Research into Health Effects.  

SciTech Connect

Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the electric and magnetic fields (EMF) produced by power lines and other electrical devices cause health effects. The purpose of this booklet is to answer some common questions that the Bonneville Power Administration (BPA) receives about the possible effects of power lines on health. First, some basic electrical terms are defined, and electric and magnetic fields are debed. Next, answers are given to several questions about recent scientific studies. Some important information about electrical safety follows. We then describe how BPA is addressing public concerns about potential health effects of power lines. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this booklet.

United States. Bonneville Power Administration.

1994-05-01T23:59:59.000Z

99

Adaptive neurofuzzy inference system-based pollution severity prediction of polymeric insulators in power transmission lines  

Science Journals Connector (OSTI)

This paper presents the prediction of pollution severity of the polymeric insulators used in power transmission lines using adaptive neurofuzzy inference system (ANFIS) model. In this work, laboratory-based pollution performance tests were carried out ...

C. Muniraj; S. Chandraseka

2011-01-01T23:59:59.000Z

100

Calculation methods and detection techniques for electric and magnetic fields from power lines with measurement verification  

E-Print Network (OSTI)

An accurate determination and characterization of electric and magnetic fields produced by power lines is a complex task. Different models must be used for far fields and for near fields. This study is centered on computation and measurement aspects...

Mamishev, Alexander V

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Electric Power Lines : Questions and Answers on Research into Health Effects.  

SciTech Connect

Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the electric and magnetic fields (EMF) produced by power lines and other electrical devices cause health effects. The purpose of this pamphlet is to answer some common questions that the Bonneville Power Administration (BPA) receives about the possible effects of power lines on health. (BPA is the Pacific Northwest`s Federal electric power marketing agency.) First, some basic electrical terms are defined, and electric and magnetic fields are described. Next, answers are given to several questions about recent scientific studies. We then describe how BPA is addressing public concerns raised by these studies. Some important information about electrical safety follows. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this pamphlet.

United States. Bonneville Power Administration.

1993-11-01T23:59:59.000Z

102

A method for calculating wide band electromagnetic interference from power line corona  

SciTech Connect

An algorithm for calculating electromagnetic interference from power line corona for a range of frequencies from 100 kHz to 30 MHz is demonstrated. It can be used for calculations at any distance or direction from the line. The algorithm incorporates an existing generation function which has been optimized by comparison to long term electromagnetic interference measurements.

Olsen, R.G. [Washington State Univ., Pullman, WA (United States). School of Electrical Engineering and Computer Science] [Washington State Univ., Pullman, WA (United States). School of Electrical Engineering and Computer Science; Schennum, S.D. [Gonzaga Univ., Spokane, WA (United States)] [Gonzaga Univ., Spokane, WA (United States)

1995-07-01T23:59:59.000Z

103

MATCASC: A tool to analyse cascading line outages in power grids  

E-Print Network (OSTI)

Blackouts in power grids typically result from cascading failures. The key importance of the electric power grid to society encourages further research into sustaining power system reliability and developing new methods to manage the risks of cascading blackouts. Adequate software tools are required to better analyze, understand, and assess the consequences of the cascading failures. This paper presents MATCASC, an open source MATLAB based tool to analyse cascading failures in power grids. Cascading effects due to line overload outages are considered. The applicability of the MATCASC tool is demonstrated by assessing the robustness of IEEE test systems and real-world power grids with respect to cascading failures.

Ko, Yakup; Araujo, Nuno A M; Warnier, Martijn

2013-01-01T23:59:59.000Z

104

High average power fundamental input couplers for the Cornell University ERL: requirements, design challenges and first ideas  

E-Print Network (OSTI)

. Therefore the buncher cavity coupling to a transmission line is determined only by the cavity wall losses of 120 kV. It turns out that the best choice would be to detune the buncher cavity halfway [2]. This reduces the required power to 6 kW at 120 kV and leaves enough power overhead to raise the cavity voltage

105

EA-0962: Construction and Routine Operation of a 12-kilovolt Overhead  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

62: Construction and Routine Operation of a 12-kilovolt 62: Construction and Routine Operation of a 12-kilovolt Overhead Powerline and Formal Authorization for a 10-inch and 8-inch Fresh Water Pipeline Right-of-Way at Naval Petroleum Reserve No. 1, Kern County, California EA-0962: Construction and Routine Operation of a 12-kilovolt Overhead Powerline and Formal Authorization for a 10-inch and 8-inch Fresh Water Pipeline Right-of-Way at Naval Petroleum Reserve No. 1, Kern County, California SUMMARY This EA evaluates the environmental impacts of the proposal to install an overhead powerline extension from the U.S. Department of Energy's Naval Petroleum Reserve No. 1 (NPR-1) power source to the WKWD Station A, which will significantly reduce NPR-1's overall utility costs. NPR-1 is known as Elk Hills oil field and is located in the southern San Joaquin Valley,

106

A Testing Platform for Validation of Overhead Conductor Aging Models and Understanding Thermal Limits  

SciTech Connect

Power system equipment manufacturers and researchers continue to experiment with novel overhead electric conductor designs that support better conductor performance and address congestion issues. To address the technology gap in testing these novel designs, Oak Ridge National Laboratory constructed the Powerline Conductor Accelerated Testing (PCAT) facility to evaluate the performance of novel overhead conductors in an accelerated fashion in a field environment. Additionally, PCAT has the capability to test advanced sensors and measurement methods for accessing overhead conductor performance and condition. Equipped with extensive measurement and monitoring devices, PCAT provides a platform to improve/validate conductor computer models and assess the performance of novel conductors. The PCAT facility and its testing capabilities are described in this paper.

Irminger, Philip [ORNL; Starke, Michael R [ORNL; Dimitrovski, Aleksandar D [ORNL; Young II, Marcus Aaron [ORNL; Rizy, D Tom [ORNL; Stovall, John P [ORNL; Overholt, Philip N [U.S. Department of Energy, Office of Electricity Delivery and Energy Reliability (OE)

2014-01-01T23:59:59.000Z

107

Nonlinear Free Vibrations of Coupled Spans of Overhead Transmission Lines  

E-Print Network (OSTI)

. In wintertime when the cable is covered by snow or ice, the cables are vulnerable to large scale vertical enough for the air-insulation to break down, causing a short-circuit and structural damage to the cables

Rienstra, Sjoerd W.

108

Wallula-McNary Transmission Line Project and Wallula Power Project EIS (DOE/EIS-0030)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

RECORD OF DECISION for the Wallula-McNary Transmission Line Project and Wallula Power Project THE DECISION The Bonneville Power Administration (BPA) has decided to implement its portion of the proposed action identified in the Wallula Power Project and Wallula-McNary Transmission Line Project Final Environmental Impact Statement (DOE/EIS-0330, August 2002). The proposed action includes construction of the Wallula Power Project (Wallula Project) that has been proposed by Wallula Generation, LLC (Wallula LLC). The proposed Wallula Project is a 1,300- megawatt (MW) natural-gas-fired, combined-cycle turbine power plant that Wallula LLC is planning to construct on a site near the Columbia River in Walla Walla County, Washington, approximately eight miles south of the City of Pasco. BPA's portion of the proposed action

109

Electric Power Lines : Questions and Answers on Research into Health Effects.  

SciTech Connect

Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the EMF (electric and magnetic fields) produced by power lines and other electrical devices affect our health. Although no adverse health effects of electric power EMF have been confirmed, there is continued scientific uncertainty about this issue. Research on EMF is ongoing throughout the world. The purpose of this booklet is to answer some common questions that the BPA (Bonneville Power Administration) receives about the possible effects of power lines on health. First, some basic electrical terms are defined, and electric and magnetic fields are debed. Next, answers are given to several questions about recent scientific studies. Some important information about electrical safety follows. We then describe how BPA is addressing public concerns about potential health effects of power lines. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this booklet.

United States. Bonneville Power Administration.

1995-06-01T23:59:59.000Z

110

Power Line Communication as a Transmission Medium for OpenADR Signals  

NLE Websites -- All DOE Office Websites (Extended Search)

Power Line Communication as a Transmission Medium for OpenADR Signals Power Line Communication as a Transmission Medium for OpenADR Signals Speaker(s): Javier Matanza Domingo Date: December 14, 2011 - 1:30pm Location: 90-3075 Seminar Host/Point of Contact: Maya Minamihara Power Line Communication (PLC) is currently considered an emerging technology and is attracting the attention of the scientific community due to the promise of new ways to transmit information. Since this transmission path reaches wherever electricity is present, one of the main motivations is its use in all kinds of energy-related applications. Some examples are: remote-metering, remote-control and demand management. However, not everything about PLC is advantageous, due to the fact that it uses a physical media, which was not designed for transmit information, and it

111

Microsoft Word - Broadband Over Power Lines_FINAL.06.01.10.doc  

NLE Websites -- All DOE Office Websites (Extended Search)

Broadband over Powerlines Can Accelerate the Transmission Smart Grid Broadband over Powerlines Can Accelerate the Transmission Smart Grid May 25, 2010 DOE/NETL-2010/1418 Broadband Over Power Lines Could Accelerate the Transmission Smart Grid Broadband Over Power Lines Could Accelerate the Transmission Smart Grid 1 Prepared by: Booz Allen Hamilton (BAH) Bruce Renz Renz Consulting, LLC DOE Contract number: DE-FE000400 Broadband Over Power Lines Could Accelerate the Transmission Smart Grid 2 Acknowledgements This report was prepared by Booz Allen Hamilton, Inc. (BAH) for the United States Department of Energy's National Energy Technology Laboratory. This work was completed under DOE NETL Contract Number DE-FE000400, and performed under BAH Task 430.04. The authors wish to acknowledge the excellent guidance, contributions, and cooperation of the

112

A system for tranmitting low frequency analog signals over ac power lines  

DOE Patents (OSTI)

A system for transmitting low frequency analog signals over ac power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an ac power line. The modulation signal frequency range is selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the ac power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal. 4 figs.

Baker, S.P.; Durall, R.L.; Haynes, H.D.

1987-07-30T23:59:59.000Z

113

System for transmitting low frequency analog signals over AC power lines  

DOE Patents (OSTI)

A system for transmitting low frequency analog signals over AC power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an AC power line. The modulation signal frequency range in selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the AC power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal.

Baker, Steven P. (Powell, TN); Durall, Robert L. (Lenoir City, TN); Haynes, Howard D. (Knoxville, TN)

1989-01-01T23:59:59.000Z

114

Breaking the ice: de-icing power transmission lines with high-frequency, high-voltage excitation  

E-Print Network (OSTI)

Breaking the ice: de-icing power transmission lines with high-frequency, high-voltage excitation of this work in other works must be obtained from the IEEE. #12;CING OF POWER TRANSMISSION lines during winter that applies 33-kV, 100-kHz power. TheoverallsystemisillustratedinFigure1.Itcouldbede- ployed in two different

115

Wallula Power Project and Wallula - McNary Transmission Line Project Final Environmental Impact Statement  

SciTech Connect

Wallula Generation, LLC proposes to construct a 1,300-megawatt (MW) natural gas-fired combined-cycle combustion gas turbine facility (the Wallula Power Project). The project would be located in the northwestern portion of Walla Walla County, Washington, approximately 8 miles south of the City of Pasco, 2 miles north of the unincorporated community of Wallula, and 7 miles southeast of the unincorporated community of Burbank. The purpose of the proposed power project is to provide energy to meet the needs of the Northwest and other interconnected electric transmission areas where electrical energy is needed. Firm transmission of the power generated by the Wallula Power Project would require construction of a new 500-kilovolt (kV) transmission line and construction of a new switchyard near Smiths Harbor. Approximately 5.1 miles of new transmission line from the proposed generation plant to the new switchyard would be completed. An additional 28 miles of new transmission line from the Smiths Harbor Switchyard to the McNary Substation would be constructed adjacent to the existing Lower Monumental-McNary transmission line and upgrades completed to the existing McNary Substation if loads are exceeded on the existing line. Wallula Generation, LLC, would construct and operate the generation plant and associated facilities, including the makeup water supply line. Bonneville would design, construct, and operate the two 500 kV transmission line segments and switchyard. To supply natural gas to the plant site, a 5.9-mile pipeline interconnection would be engineered, constructed, owned, and operated by PG&E Gas Transmission-Northwest (GTN). This EIS evaluates the environmental impacts of the proposed action, which includes the proposed power plant and 33-mile transmission line. It also evaluates an alternative using taller towers and longer spans between towers along part of the transmission line, and the use of an alternative approach for the transmission line where it would enter the McNary Substation. The No Action Alternative is also addressed.

N /A

2002-08-16T23:59:59.000Z

116

Using Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage  

E-Print Network (OSTI)

capable of exciting a 1 m test line to 30 kV has been tested and show to be capable of removing a 7 mm iceUsing Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage Excitation J DIELECTRIC LOSSES TO DE-ICE POWER TRANSMISSION LINES . . . 1 Using Dielectric Losses to De-Ice Power

117

HHFW Power Flow Along Magnetic Field Lines In The Scrape-off Layer of NSTX  

SciTech Connect

A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast wave heating and current drive.

Rory Perkins, et. al.

2012-02-27T23:59:59.000Z

118

2014 NSERC USRA Summer Projects Power Line Communications for Electric Vehicles  

E-Print Network (OSTI)

2014 NSERC USRA Summer Projects Power Line Communications for Electric Vehicles Prof. Victor C become significant, especially in electric vehicles (EVs) of the future, which are highly sophisticated.M. Leung (vleung@ece.ubc.ca) 1. Project description In today's electric and conventional combustion engine

Leung, Victor C.M.

119

Power Transmission Lines: A New Interconnect Design to Eliminate Simultaneous Switching Noise A. Ege Engin and Madhavan Swaminathan  

E-Print Network (OSTI)

Power Transmission Lines: A New Interconnect Design to Eliminate Simultaneous Switching Noise A occurs at discontinuities of the transmission line, wherever there is an interruption of the current that is connected to a transmission line. To reduce this discontinuity, current designs try to maintain a low

Swaminathan, Madhavan

120

650 IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 26, NO. 2, APRIL 2011 Hourly Scheduling of DC Transmission Lines in  

E-Print Network (OSTI)

Transmission Lines in SCUC With Voltage Source Converters Azim Lotfjou, Mohammad Shahidehpour, Fellow, IEEE transmission lines, se- curity-constrained unit commitment, voltage-source converters. NOMENCLATURE Index of ac;LOTFJOU et al.: HOURLY SCHEDULING OF DC TRANSMISSION LINES 651 , Vector of real and reactive power

Fu, Yong

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Wallula Power Project and Wallula - McNary Transmission Line Project, Final Environmental Impact Statement  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and and Wallula - McNary Transmission Line Project Final Environmental Impact Statement DOE/EIS-0330 Lead Agencies Bonneville Power Administration Washington State Energy Facility Site Evaluation Council Cooperating Agencies Bureau of Land Management U.S. Fish and Wildlife Service August 2002 EFSEC Washington State Energy Facility Site Evaluation Council August 2002 Dear Reader: Enclosed for your reference is the abbreviated form Final Environmental Impact Statement (FEIS) for the proposed Wallula Power Project and Wallula-McNary Transmission Line Project. This document is designed to supplement or correct information provided in the Draft Environmental Impact Statement (DEIS). The proponent, Wallula Generation, LLC, has requested to build a 1,300-megawatt, gas-fired

122

A Fast, Robust Algorithm for Power Line Interference Cancellation in Neural Recording  

E-Print Network (OSTI)

Power line interference may severely corrupt neural recordings at 50/60 Hz and harmonic frequencies. In this paper, we present a robust and computationally efficient algorithm for removing power line interference from neural recordings. The algorithm includes four steps. First, an adaptive notch filter is used to estimate the fundamental frequency of the interference. Subsequently, based on the estimated frequency, harmonics are generated by using discrete-time oscillators, and then the amplitude and phase of each harmonic are estimated through using a modified recursive least squares algorithm. Finally, the estimated interference is subtracted from the recorded data. The algorithm does not require any reference signal, and can track the frequency, phase, and amplitude of each harmonic. When benchmarked with other popular approaches, our algorithm performs better in terms of noise immunity, convergence speed, and output signal-to-noise ratio (SNR). While minimally affecting the signal bands of interest, the a...

Keshtkaran, Mohammad Reza

2014-01-01T23:59:59.000Z

123

Termination for a superconducting power transmission line including a horizontal cryogenic bushing  

DOE Patents (OSTI)

A termination for a superconducting power transmission line is disclosed which is comprised of a standard air entrance insulated vertical bushing with an elbow, a horizontal cryogenic bushing linking the pressurized cryogenic cable environment to the ambient temperature bushing and a stress cone which terminates the cable outer shield and transforms the large radial voltage gradient in the cable dielectric into a much lower radial voltage gradient in the high density helium coolant at the cold end of the cryogenic bushing.

Minati, Kurt F. (Northport, NY); Morgan, Gerry H. (Patchogue, NY); McNerney, Andrew J. (Shoreham, NY); Schauer, Felix (Upton, NY)

1984-01-01T23:59:59.000Z

124

Route selection and detailed line design  

Science Journals Connector (OSTI)

The requirements for route selection and detailed line design of a high-voltage overhead line are established by the preparatory work, studies ... the required starting and terminal point of a transmission connec...

Dr.-Ing. Friedrich Kiessling; Dipl.-Ing. Peter Nefzger

2003-01-01T23:59:59.000Z

125

DATA-DRIVEN ON-LINE PREDICTION OF THE AVAILABLE RECOVERY TIME IN NUCLEAR POWER PLANT FAILURE SCENARIOS  

E-Print Network (OSTI)

1 DATA-DRIVEN ON-LINE PREDICTION OF THE AVAILABLE RECOVERY TIME IN NUCLEAR POWER PLANT FAILURE-XADS). Key Words: Recovery Time, Emergency Accident Management, Nuclear Power Plant, Lead- Bismuth Eutectic e-26Jul2012 Author manuscript, published in "ESREL 2010 (2010) 1 - 8" #12;2 1. Introduction Nuclear Power

Boyer, Edmond

126

Determination of High-Frequency Current Distribution Using EMTP-Based Transmission Line Models with Resulting Radiated Electromagnetic Fields  

SciTech Connect

Application of BPL technologies to existing overhead high-voltage power lines would benefit greatly from improved simulation tools capable of predicting performance - such as the electromagnetic fields radiated from such lines. Existing EMTP-based frequency-dependent line models are attractive since their parameters are derived from physical design dimensions which are easily obtained. However, to calculate the radiated electromagnetic fields, detailed current distributions need to be determined. This paper presents a method of using EMTP line models to determine the current distribution on the lines, as well as a technique for using these current distributions to determine the radiated electromagnetic fields.

Mork, B; Nelson, R; Kirkendall, B; Stenvig, N

2009-11-30T23:59:59.000Z

127

Lossless fault-tolerant data structures with additive overhead  

E-Print Network (OSTI)

We develop the first dynamic data structures that tolerate ? memory faults, lose no data, and incur only an O(? ) additive overhead in overall space and time per operation. We obtain such data structures for arrays, linked ...

Christiano, Paul F.

128

A comparative analysis of the technical and economic indicators characterizing independent small-capacity power installations for supplying power to trunk gas lines and gas distribution stations  

Science Journals Connector (OSTI)

Results obtained from a feasibility study of different independent sources of energy are presented, using which one can select them on a sound basis for supplying heat and power for trunk gas lines and gas distri...

G. A. Fokin

2010-11-01T23:59:59.000Z

129

Transmission line modeling with explicit grounding representation  

Science Journals Connector (OSTI)

This paper presents a new model of an overhead transmission line for electromagnetic transient computations. The unique feature of the model is the explicit representation of the tower grounding configuration and terminal substation grounds. Other properties of the model are: (1) accurate frequency dependent parameter representation from DC to several MHz; (2) explicit modeling of line asymmetries; and (3) high numerical efficiency. The model implementation is based on the solution of the transmission line differential equations resulting in a set of step response functions, forming a matrix. The step response matrix is utilized in a time domain simulation of electric power networks by a linear convolution scheme. The transmission line model is validated with actual system test data. The model is useful for computing the ground potential rise of transmission towers due to lightning or switching surges, insulation stress, etc. Typical applications are described in the paper.

G.J. Cokkinides; A.P.Sakis Meliopoulos

1988-01-01T23:59:59.000Z

130

On-line Decentralized Charging of Plug-In Electric Vehicles in Power Systems  

E-Print Network (OSTI)

Plug-in electric vehicles (PEV) are gaining increasing popularity in recent years, due to the growing societal awareness of reducing greenhouse gas (GHG) emissions and the dependence on foreign oil or petroleum. Large-scale implementation of PEVs in the power system currently faces many challenges. One particular concern is that the PEV charging can potentially cause significant impact on the existing power distribution system, due to the increase in peak load. As such, this work tries to mitigate the PEV charging impact by proposing a decentralized smart PEV charging algorithm to minimize the distribution system load variance, so that a 'flat' total load profile can be obtained. The charging algorithm is on-line, in that it controls the PEV charging processes in each time slot based entirely on the current power system state. Thus, compared to other forecast based smart charging approaches in the literature, the charging algorithm is robust against various uncertainties in the power system, such as random PE...

Li, Qiao; Negi, Rohit; Franchetti, Franz; Ilic, Marija D

2011-01-01T23:59:59.000Z

131

Network interface active messages for low overhead communication on SMP PC clusters  

Science Journals Connector (OSTI)

Keywords: active messages, barrier synchronization, cluster computing, latency hiding, low-overhead communication

Motohiko Matsuda; Yoshio Tanaka; Kazuto Kubota; Mitsuhisa Sato

2000-03-01T23:59:59.000Z

132

Treatment of biodiversity issues in impact assessment of electricity power transmission lines: A Finnish case review  

Science Journals Connector (OSTI)

The Environmental Impact Assessment (EIA) process concerning the route of a 400 kV power transmission line between Loviisa and Hiki in southern Finland was reviewed in order to assess how biodiversity issues are treated and to provide suggestions on how to improve the effectiveness of treatment of biodiversity issues in impact assessment of linear development projects. The review covered the whole assessment process, including interviews of stakeholders, participation in the interest group meetings and review of all documents from the project. The baseline studies and assessment of direct impacts in the case study were detailed but the documentation, both the assessment programme and the assessment report, only gave a partial picture of the assessment process. All existing information, baseline survey and assessment methods should be addressed in the scoping phase in order to promote interaction between all stakeholders. In contrast to the assessment of the direct effects, which first emphasized impacts on the nationally important and protected flying squirrel but later expanded to deal with the assessment of impacts on ecologically important sites, the indirect and cumulative impacts of the power line were poorly addressed. The public was given the opportunity to become involved in the EIA process. However, they were more concerned with impacts on their properties and less so on biodiversity and species protection issues. This suggests that the public needs to become more informed about locally important features of biodiversity.

Tarja Sderman

2006-01-01T23:59:59.000Z

133

Sensor, method and system of monitoring transmission lines  

SciTech Connect

An apparatus, method, and system for measuring the magnetic field produced by phase conductors in multi-phase power lines. The magnetic field measurements are used to determine the current load on the conductors. The magnetic fields are sensed by coils placed sufficiently proximate the lines to measure the voltage induced in the coils by the field without touching the lines. The x and y components of the magnetic fields are used to calculate the conductor sag, and then the sag data, along with the field strength data, can be used to calculate the current load on the line and the phase of the current. The sag calculations of this invention are independent of line voltage and line current measurements. The system applies a computerized fitter routine to measured and sampled voltages on the coils to accurately determine the values of parameters associated with the overhead phase conductors.

Syracuse, Steven J.; Clark, Roy; Halverson, Peter G.; Tesche, Frederick M.; Barlow, Charles V.

2012-10-02T23:59:59.000Z

134

DOE-HDBK-1141-2001; Radiological Assessor Training, Overheads  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

13.1 13.1 Overhead 13.1 DOE-HDBK-1141-2001 Radiological Aspects of Accelerators Objectives: * Identify the general characteristics of accelerators. * Identify the types of particles accelerated. * Identify the two basic types of accelerators. * Identify uses for accelerators. * Define prompt radiation. * Identify prompt radiation sources. OT 13.2 Overhead 13.2 DOE-HDBK-1141-2001 Radiological Aspects of Accelerators (cont.) Objectives: * Define radioactivation. * Explain how contaminated material differs from activated material with regard to radiological concerns. * Identify activation sources. OT 13.3 Overhead 13.3 DOE-HDBK-1141-2001 Radiological Aspects of Accelerators (cont.) Objectives: * Identify engineered and administrative controls at accelerator facilities. * Identify the special

135

Tucson Electric Power Company Sahuarita-Nogales Transmission Line Draft Environmental Impact Statement  

SciTech Connect

Tucson Electric Power Company (TEP) has applied to the U.S. Department of Energy (DOE) for a Presidential Permit to construct and operate a double-circuit, 345,000-volt (345-kV) electric transmission line across the United States border with Mexico. Under Executive Order (EO) 10485 of September 3, 1953, as amended by EO 12038 of February 3, 1978, a Presidential Permit is required to construct, connect, operate, or maintain facilities at the U.S. international border for the transmission of electric energy between the United States and a foreign country. DOE has determined that the issuance of a Presidential Permit to TEP for the proposed project would constitute a major Federal action that may have a significant impact on the environment within the meaning of the ''National Environmental Policy Act of 1969'' (NEPA) 42 United States Code (U.S.C.) {section}4321 et seq. For this reason, DOE has prepared this Draft Environmental Impact Statement (EIS) to evaluate potential environmental impacts from the proposed Federal action (granting a Presidential Permit for the proposed transmission facilities) and reasonable alternatives, including the No Action Alternative. This EIS was prepared in accordance with Section 102(2)(c) of NEPA, Council of Environmental Quality (CEQ) regulations (40 Code of Federal Regulations [CFR] 1500-1508), and DOE NEPA Implementing Procedures (10 CFR 1021). DOE is the lead Federal Agency, as defined by 40 CFR 1501.5. The U.S. Department of Agriculture Forest Service (USFS), the Bureau of Land Management (BLM) of the U.S. Department of the Interior, and the U.S. Section of the International Boundary and Water Commission, U.S. and Mexico (USIBWC), are cooperating agencies. Each of these organizations will use the EIS for its own NEPA purposes, as described in the Federal Agencies' Purpose and Need and Authorizing Actions section of this summary. The 345-kV double-circuit transmission line would consist of twelve transmission line wires, or conductors, and two neutral ground wires that would provide both lightning protection and fiber optic communications, on a single set of support structures. The transmission line would originate at TEP's existing South Substation (which TEP would expand), in the vicinity of Sahuarita, Arizona, and interconnect with the Citizens Communications (Citizens) system at a Gateway Substation that TEP would construct west of Nogales, Arizona. The double-circuit transmission line would continue from the Gateway Substation south to cross the U.S.-Mexico border and extend approximately 60 miles (mi) (98 kilometers [km]) into the Sonoran region of Mexico, connecting with the Comision Federal de Electricidad (CFE, the national electric utility of Mexico) at CFE's Santa Ana Substation.

N /A

2003-08-27T23:59:59.000Z

136

ANUEADflM-31 Electric Power High-Voltage Transmission Lines:  

Office of Scientific and Technical Information (OSTI)

ANUEADflM-31 ANUEADflM-31 Electric Power High-Voltage Transmission Lines: Design Options, Cost, and Electric and Magnetic Field Levels by J.B. Stoffel,' E.D. Pentecost, R.D. Roman, and P.A. Traczyk Environmental Assessment Division, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 November 1994 Work sponsored by United States Department of Energy, Assistant Secretary for Fossil Energy, Office of Fuels Program Stoffel is affiliated with Argonne's Electronics and Computing Technologies Division. D4SlRlBUTlON OF THIS DOCUMENT IS UNLiMltEb - . - . - . - . ... - , . ^ ~ .. , . . . , . . _ I T h i s report i s printed on recycled paper. @ . . .. . ' . . . A :_ - .. ., . . DISCLAIMER This report was .prepared as an account of work sponsored by an agency of the United States Government. Neither

137

Wallula Power Project and Wallula - McNary Transmission Line Project, Final Environmental Impact Statement  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Final EIS Appendix A: Revised Mitigation Measures Final EIS Appendix A: Revised Mitigation Measures August 2002 Page A-1 Appendix A Revised Mitigation Measures The proposed project includes measures that would limit construction and operation impacts to elements of the natural and human environment. These measures are presented for each element of the environment identified as a potential concern by Bonneville and EFSEC based on preliminary environmental review and public and regulatory agency input. Updates to the mitigation table below are in response to comments on the Draft EIS or to incorporate new information included in the Settlement Agreements. Mitigation Measure Power Plant Pipelines Bonneville T-Line EARTH Seismicity Facilities would be designed to meet regional seismic design criteria as presented in the Uniform Building Code (UBC). X X

138

Nuclear power plant on-line sensor calibration monitoring implementation issues  

Science Journals Connector (OSTI)

The use of empirical models for on-line monitoring (OLM) of safety-critical instrumentation for calibration reduction has been investigated for over a decade. To help support the regulatory review of possible licence amendments for US nuclear power plants, a series of three NUREG/CRs is being developed for the US Nuclear Regulatory Commission. The third of these volumes, entitled 'Limiting Case Studies', presents the results of applying OLM models to a wide variety of plant data. Specifically, Volume III summarises seven case studies investigating the effects of model development and data assumptions on model performance, and offers recommendations for identifying and handling these limiting cases. This paper discusses the seven case studies. Although this study is not an exhaustive review of the many issues in OLM system development, it provides a base set of considerations that must be accounted for and a method for testing these considerations with other model architectures.

Jamie Garvey; Dustin Garvey; Rebecca Seibert; J. Wesley Hines

2007-01-01T23:59:59.000Z

139

On-line mechanical tube cleaning for steam electric power plants. Final report  

SciTech Connect

In July 1991, Superior I.D. Tube Cleaners, Inc. (SIDTEC{trademark}) received a grant through the Department of Energy and the Energy Related Invention Program to conduct a long term demonstration of a proprietary technology for on-line mechanical condenser tube cleaning in thermal Power plants on open or once-through cooling water systems where the warmed condenser cooling water is discharged through a canal. The purpose of the demonstration was to confirm and establish the use of this mechanical method as an alternative to the application of chemical biocides in condenser cooling water for the control of biofouling, the growth of micro-organisms which can reduce a unit`s operating efficiency. The SIDTEC on-line mechanical tube cleaner, the Rocket{trademark}, is used to physically remove accumulated deposits on the water side of the main steam condenser, and the non-intrusive tube cleaner recovery system, the Skimmer{trademark}, is used to recover and recirculate tube cleaners. The periodic circulation of tube cleaners can maintain optimum condenser cleanliness and improve unit heat rate. Thermal power plants which discharge condenser cooling water through a canal now have a viable alternative to the chemical treatment of condenser cooling water, whether the principal foulant is biofouling, chemical scaling, silting, or a combination of the three. At prices competitive with scale inhibitors, and a fraction of competing mechanical systems, this technology is provided as a service requiring no capital investment; minimal retrofit modifications to plant structures or equipment; can be installed and maintained without a unit shutdown; does not add any restrictions in the cooling water system; and is environmentally benign.

Not Available

1994-02-18T23:59:59.000Z

140

Total compensation of line-side switching harmonics in converter-fed ac locomotives  

SciTech Connect

PWM controlled line-side converters of modern ac traction locomotives inject harmonic currents into the feeding overhead line. This causes problems of electromagnetic interference. Passive or active filters are usually provided for a partial reduction of the line harmonics. A novel and superior approach employs a switched electronic compensator. It generates an exact replica of the harmonic current, feeding it to the high-voltage transformer to produce a harmonic counter MMF. The transformer main flux is then forced to be sinusoidal, and so is the induced voltage in the primary. The line current, being low-pass filtered by the transformer leakage inductance, assumes a pure sinusoidal waveform. The compensator operates in the low switching frequency range of the main power converters. Its installed power is only 1% of the traction power. Operation, control, and design considerations are described. Results from laboratory tests at full power level are presented.

Krah, J.O.; Holtz, J. [Univ. of Wuppertal (Germany)] [Univ. of Wuppertal (Germany)

1995-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Microsoft PowerPoint - [5] Le Tang - ABB Presentation at DOE HVDC Workshop  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVDC Technologies & ABB Experience HVDC Technologies & ABB Experience DOE Workshop - Applications for High-Voltage Direct Current Transmission Technologies Le Tang, ABB , April 22, 2013 In cable > 50 km (>30 miles), most of AC current is needed to charge and discharge In overhead lines > 200 km (>120 miles), most of AC voltage is needed to G G load I C = ωCU 0 U L = ωLI 0 I 0 U 0 I = I 0 - I C U=U 0 -U L Cable Overhead Line C load L Why is DC important in the Transmission Grid ? Capacitance and Inductance of Power Line © ABB Group April 22, 2013 | Slide 2 current is needed to charge and discharge the "C" (capacitance) of the cable most of AC voltage is needed to overcome the "L" (inductance) of the line ⇒ C& L can be compensated by reactors/capacitors or FACTS ⇒ or by use of DC, which means

142

Mode Initialization for On-line Estimation of Power System Electromechanical Modes  

SciTech Connect

Measurement-based mode estimation methods are utilized to estimate electromechanical modes of a power system using phasor measurement units (PMU) data. These methods need to extract a certain amount of information before they can give useable mode estimation. Traditionally, the information is gathered solely from measurement data. Priori mode information from other resources (e.g. model eigenvalue analysis, engineering knowledge) are not fully utilized. For real time application, this means that mode estimation takes time to converge. By adding a mode regularization term in the objective function, this paper proposes a mode initialization method to include priori mode information in a regularized robust recursive least squares (R3LS) algorithm for on-line mode estimation. The proposed method is tested using a simple model, a 17 machine model and is shown to be able to shorten the convergence period of the R3LS algorithm. The proposed method is also applied on the measurement data recorded right before a major power outage in the western North American Grid on August 10th 1996 to show its potential applica-tion in detecting an approaching small signal stability problem.

Zhou, Ning; Trudnowski, Daniel; Pierre, John W.

2009-03-18T23:59:59.000Z

143

Reducing Diff Overhead in Software DSM Systems using  

E-Print Network (OSTI)

Reducing Diff Overhead in Software DSM Systems using RDMA Operations in InfiniBand Ranjit Noronha;Introduction and Motivation Software DSM Modern computer networks Design and Implementation Diff creation and Future Work Outline #12;Software DSM Software DSM (SDSM) HLRC/VIA (Rutgers), TreadMarks (Rice) Depends

Panda, Dhabaleswar K.

144

On-line partial discharge monitoring system and data processing using WTST-NST filter for high voltage power cable  

Science Journals Connector (OSTI)

Defects inside insulation of HV XLPE cable accessories can lead to partial discharge (PD) activity. When PD activity happens, leakage current may flow through the grounded line. To acquire the PD current signal, one practicable and effective method is ... Keywords: MRD-MRR algorithm, adaptive WTST-NST filter, condition based maintenance(CBM), on-line monitoring, partial discharge, power cable, stationary noise interference

Hui Wang; Chengjun Huang; Li Zhang; Yong Qian; Junhua Liu; Linpeng Yao; Canxin Guo; Xiuchen Jiang

2009-07-01T23:59:59.000Z

145

INTEGRATED VERTICAL AND OVERHEAD DECONTAMINATION (IVOD) SYSTEM  

SciTech Connect

The deactivation and decommissioning of 1200 buildings within the U.S. Department of Energy-Office of Environmental Management complex will require the disposition of a large quantity of contaminated concrete and metal surfaces. It has been estimated that 23 million cubic meters of concrete and over 600,000 tons of metal will need disposition. The disposition of such large quantities of material presents difficulties in the area of decontamination and characterization. The final disposition of this large amount of material will take time and money as well as risk to the D&D work force. A single automated system that would decontaminate and characterize surfaces in one step would not only reduce the schedule and decrease cost during D&D operations but would also protect the D&D workers from unnecessary exposures to contaminated surfaces. This report summarizes the activities performed during FY00 and describes the planned activities for FY01. Accomplishments for FY00 include the following: Development and field-testing of characterization system; Completion of Title III design of deployment platform and decontamination unit; In-house testing of deployment platform and decontamination unit; Completion of system integration design; Identification of deployment site; and Completion of test plan document for deployment of IVOD at Rancho Seco nuclear power facility.

M.A. Ebadian, Ph.D.

2001-01-01T23:59:59.000Z

146

Bonneville Power Administration Grand Coulee-Bell 500-kV Transmission Line Project Record of Decision  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Grand Coulee-Bell 500-kV Transmission Line Project Grand Coulee-Bell 500-kV Transmission Line Project Record of Decision Decision The Bonneville Power Administration (BPA) has decided to construct the proposed Grand Coulee-Bell 500-kV Transmission Line Project in Douglas, Grant, Lincoln, and Spokane Counties, Washington. BPA has decided to implement the proposed action identified in the Grand Coulee-Bell 500-kV Transmission Line Project Final Environmental Impact Statement (DOE/EIS-0344, December 2002). The proposed action consists of constructing a new 500- kilovolt (kV) transmission line between the Bureau of Reclamation's (BOR) Grand Coulee 500- kV Switchyard near Grand Coulee, Washington, and BPA's Bell Substation near Spokane, a distance of 84 miles. The proposed action involves removing an existing 115-kV transmission

147

Amended Application for Presidential Permit OE Docket No. PP-398 Minnesota Power- Great Northern Transmission Line: Federal Register Notice, Volume 79, No. 222- Nov. 18, 2014  

Energy.gov (U.S. Department of Energy (DOE))

Minnesota Power, Great Northern Transmission Line has submitted an amended application for a Presidential Permit to construct, operate, maintain and connect an electric transmission line across the United States border with Canada.

148

Developing Effective Continuous On-Line Monitoring Technologies to Manage Service Degradation of Nuclear Power Plants  

SciTech Connect

Recently, there has been increased interest in using prognostics (i.e, remaining useful life (RUL) prediction) for managing and mitigating aging effects in service-degraded passive nuclear power reactor components. A vital part of this philosophy is the development of tools for detecting and monitoring service-induced degradation. Experience with in-service degradation has shown that rapidly-growing cracks, including several varieties of stress corrosion cracks (SCCs), can grow through a pipe in less than one fuel outage cycle after they initiate. Periodic inspection has limited effectiveness at detecting and managing such degradation requiring a more versatile monitoring philosophy. Acoustic emission testing (AET) and guided wave ultrasonic testing (GUT) are related technologies with potential for on-line monitoring applications. However, harsh operating conditions within NPPs inhibit the widespread implementation of both technologies. For AET, another hurdle is the attenuation of passive degradation signals as they travel though large components, relegating AET to targeted applications. GUT is further hindered by the complexity of GUT signatures limiting its application to the inspection of simple components. The development of sensors that are robust and inexpensive is key to expanding the use of AET and GUT for degradation monitoring in NPPs and improving overall effectiveness. Meanwhile, the effectiveness of AET and GUT in NPPs can be enhanced through thoughtful application of tandem AET-GUT techniques.

Meyer, Ryan M.; Ramuhalli, Pradeep; Bond, Leonard J.; Cumblidge, Stephen E.

2011-09-30T23:59:59.000Z

149

High-Harmonic Fast-Wave Power Flow along Magnetic Field Lines in the Scrape-Off Layer of NSTX  

Science Journals Connector (OSTI)

A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast-wave heating and current drive.

R. J. Perkins; J. C. Hosea; G. J. Kramer; J.-W. Ahn; R. E. Bell; A. Diallo; S. Gerhardt; T. K. Gray; D. L. Green; E. F. Jaeger; M. A. Jaworski; B. P. LeBlanc; A. McLean; R. Maingi; C. K. Phillips; L. Roquemore; P. M. Ryan; S. Sabbagh; G. Taylor; J. R. Wilson

2012-07-27T23:59:59.000Z

150

High-Harmonic Fast-Wave Power Flow Along Magnetic Field Lines in the Scrape-Off Layer of NSTX  

SciTech Connect

A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast-wave heating and current drive.

Perkins, R. J. [Princeton Plasma Physics Laboratory (PPPL); Hosea, J. [Princeton Plasma Physics Laboratory (PPPL); Kramer, G. [Princeton Plasma Physics Laboratory (PPPL); Ahn, Joonwook [ORNL; Bell, R. E. [Princeton Plasma Physics Laboratory (PPPL); Diallo, A. [Princeton Plasma Physics Laboratory (PPPL); Gerhardt, S. [Princeton Plasma Physics Laboratory (PPPL); Gray, T. K. [Oak Ridge National Laboratory (ORNL); Green, David L [ORNL; Jaeger, Erwin Frederick [ORNL; Jaworski, M. A. [Princeton Plasma Physics Laboratory (PPPL); LeBlanc, B [Princeton Plasma Physics Laboratory (PPPL); McLean, Adam G [ORNL; Maingi, Rajesh [ORNL; Phillips, C. K. [Princeton Plasma Physics Laboratory (PPPL); Roquemore, L. [Princeton Plasma Physics Laboratory (PPPL); Ryan, Philip Michael [ORNL; Sabbagh, S. A. [Columbia University; Taylor, G. [Princeton Plasma Physics Laboratory (PPPL); Wilson, J. R. [Princeton Plasma Physics Laboratory (PPPL)

2012-01-01T23:59:59.000Z

151

A technical note about Phidel: a new software for evaluating magnetic induction field generated by power lines  

Science Journals Connector (OSTI)

......measurements collected near two 380 kV power lines(10) (Figure 7) using the LINDA system, made by an EMDEX II field meter (by Enertech Consultants) fixed on a mobile support, supplied with an odometer. This simultaneously records the field values, the time......

M. Comelli; M. Benes; A. Bampo; R. Villalta

2007-02-01T23:59:59.000Z

152

CEM 2010, April 7-9 2010, Limoges France 1 Abstract--Power Line Communication (PLC) is a technique  

E-Print Network (OSTI)

CEM 2010, April 7-9 2010, Limoges France 1 Abstract-- Power Line Communication (PLC) is a technique used to deliver information over the electrical networks. The capacity and performance of PLC has PLC systems and radio broadcasters. Due to their dispersive nature, the PLC channels offer a rich

Brest, Université de

153

Technical and environmental aspects of electric power transmission  

SciTech Connect

This document summarizes the salient aspects of power systems and transmission-line technology and the effects of power-line construction and operation on human health and the environment. Major components of power systems are identified from the level of the individual consumer to that of the power pool, including the distribution, subtransmission, transmission, and power pool levels. This is followed by descriptions of the constituent parts and construction of power lines and the operational requirements and features of power lines and systems. Examples of topics include structure and conductor types, design, and selection; switching station and substation design and operation; and transmission line construction and upgrading. Emphasis is on the operational characteristics of transmission lines and of power systems and pools, including conductor and line parameters, insulation, faults, fault protection, electromagnetic field phenomena, corona phenomena, conductor motion, undesirable voltage levels, compensation, system protection, and system stability, reliability, and adequacy. Overhead dc lines, underground lines, and regulations and safety codes pertaining to power lines are briefly discussed. Environmental effects discussed include those stemming from route selection, clearing and construction, power-line operation, right-of-way maintenance, and the physical presence of structures. Examples of specific topics include visual and ecological criteria for route selection; right-of-way acquisition and land-use rights; effects of construction on soils, vegetation, and wildlife; impacts of right-of-way maintenance with herbicides or by cutting; types and use of herbicides; and power-line structure interference with TV reception and bird migration. Finally, the environmental impacts of the construction and operation of ac and dc underground lines are discussed.

Kroodsma, R.L.; Van Dyke, J.W.

1985-05-01T23:59:59.000Z

154

Recommended U-factors for swinging, overhead, and revolving doors  

SciTech Connect

Doors are often an overlooked component in the thermal integrity of the building envelope. Although swinging doors represent a small portion of the shell in residential buildings, their U-factor is usually many times higher than those of walls or ceilings. In some commercial buildings, loading (overhead) doors represent a significant area of high heat loss. Contrary to common perception, there is a wide range in the design, type, and therefore thermal performance of doors. The 1997 ASHRAE Handbook of Fundamentals will contain expanded tables of door U-factors to account for these product variations. This paper presents the results of detailed computer simulations of door U-factors. Recommended U-factors for glazed and unglazed residential and commercial swinging doors and commercial/industrial overhead and revolving doors are presented.

Carpenter, S.C. [Enermodal Engineering Ltd., Waterloo, Ontario (Canada); Hogan, J. [Seattle Dept. of Construction and Land Use, WA (United States)

1996-11-01T23:59:59.000Z

155

Line-Fault Ride-Through (LFRT) Capabilities of DFIG Wind Turbine Connected to the Power System  

Science Journals Connector (OSTI)

Abstract With increased penetration of wind power into electrical grids, DFIG wind turbines are largely deployed due to their variable speed feature and hence influencing system dynamics. According to grid codes issued by utilities, tripping of wind turbines following power system faults is not allowed. Besides, to provide voltage support to the grid, reactive current supply is necessary. This paper studies the power flow (PF) of two different networks, the first is a transmission network and the second is a distribution one, A wind Doubly-Fed Induction Generator (DFIG) turbine is injected to these different networks. A line fault right through (LFRT) is applied on each network and the power flow results are given and compared, then a new solution is proposed to connect the wind turbine to the distribution network with a down transformer to not disconnect the wind turbine during the LFRT, the power system analysis toolbox (PSAT) is used in this work.

A. Khattara; M. Bahri; A. Aboubou; M. Becherif; M.Y. Ayad

2013-01-01T23:59:59.000Z

156

EA-1679: Grand Coulee's Third Powerplant 500-kV Transmission Line  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

79: Grand Coulee's Third Powerplant 500-kV Transmission Line 79: Grand Coulee's Third Powerplant 500-kV Transmission Line Replacement Project, Grant and Okanogon Counties, Washington EA-1679: Grand Coulee's Third Powerplant 500-kV Transmission Line Replacement Project, Grant and Okanogon Counties, Washington Summary This EA evaluates potential environmental impacts from the construction and operation of six new 500-kV overhead transmission lines to replace six existing underground lines at Grand Coulee Dam. DOE's Bonneville Power Administration (BPA), a cooperating agency, was asked by the U. S. Department of the Interior's Bureau of Reclamation to design and construct the proposed new transmission lines. A Finding of No Significant Impact was issued by BPA in December 2011. BPA website: http://efw.bpa.gov/environmental_services/Document_Library/Grand_Coulee/

157

SunLine Transit Agency Hydrogen-Powered Transit Buses: Evaluation Results Update  

Energy.gov (U.S. Department of Energy (DOE))

This report provides an update on the evaluation results for hydrogen and CNG-fueled buses opertating at SunLine Transit Agency in California.

158

Fast-wave power flow along SOL field lines in NSTX and the associated power deposition profile across the SOL in front of the antenna  

Science Journals Connector (OSTI)

Fast-wave heating and current drive efficiencies can be reduced by a number of processes in the vicinity of the antenna and in the scrape-off layer (SOL). On NSTX from around 25% to more than 60% of the high-harmonic fast-wave power can be lost to the SOL regions, and a large part of this lost power flows along SOL magnetic field lines and is deposited in bright spirals on the divertor floor and ceiling. We show that field-line mapping matches the location of heat deposition on the lower divertor, albeit with a portion of the heat outside of the predictions. The field-line mapping can then be used to partially reconstruct the profile of lost fast-wave power at the midplane in front of the antenna, and the losses peak close to the last closed flux surface as well as the antenna. This profile suggests a radial standing-wave pattern formed by fast-wave propagation in the SOL, and this hypothesis will be tested on NSTX-U. RF codes must reproduce these results so that such codes can be used to understand this edge loss and to minimize RF heat deposition and erosion in the divertor region on ITER.

R.J. Perkins; J.-W. Ahn; R.E. Bell; A. Diallo; S. Gerhardt; T.K. Gray; D.L. Green; E.F. Jaeger; J.C. Hosea; M.A. Jaworski; B.P. LeBlanc; G.J. Kramer; A. McLean; R. Maingi; C.K. Phillips; M. Podest; L. Roquemore; P.M. Ryan; S. Sabbagh; F. Scotti; G. Taylor; J.R. Wilson

2013-01-01T23:59:59.000Z

159

Fast-wave Power Flow Along SOL Field Lines In NSTX nd The Associated Power Deposition Profile Across The SOL In Front Of The Antenna  

SciTech Connect

Fast-wave heating and current drive efficiencies can be reduced by a number of processes in the vicinity of the antenna and in the scrape off layer (SOL). On NSTX from around 25% to more than 60% of the high-harmonic fast-wave power can be lost to the SOL regions, and a large part of this lost power flows along SOL magnetic field lines and is deposited in bright spirals on the divertor floor and ceiling. We show that field-line mapping matches the location of heat deposition on the lower divertor, albeit with a portion of the heat outside of the predictions. The field-line mapping can then be used to partially reconstruct the profile of lost fast-wave power at the midplane in front of the antenna, and the losses peak close to the last closed flux surface (LCFS) as well as the antenna. This profile suggests a radial standing-wave pattern formed by fast-wave propagation in the SOL, and this hypothesis will be tested on NSTX-U. Advanced RF codes must reproduce these results so that such codes can be used to understand this edge loss and to minimize RF heat deposition and erosion in the divertor region on ITER.

Perkins, Roy

2013-06-21T23:59:59.000Z

160

On-line monitoring of power curves Andrew Kusiak*, Haiyang Zheng, Zhe Song  

E-Print Network (OSTI)

. The power coefficient indicates the effi- ciency of a turbine capturing the wind energy, and it is optimized and Industrial Engineering, 3131 Seamans Center, The University of Iowa, Iowa City, IA 52242 ­ 1527, USA a r t i of wind turbines is presented. Turbine performance is captured with a power curve. The power curves

Kusiak, Andrew

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Numerical investigation of the physical model of a high-power electromagnetic wave in a magnetically insulated transmission line  

SciTech Connect

An efficient numerical code for simulating the propagation of a high-power electromagnetic pulse in a vacuum transmission line is required to study the physical phenomena occurring in such a line, to analyze the operation of present-day megavolt generators at an {approx}10-TW power level, and to design such new devices. The main physical theoretical principles are presented, and the stability of flows in the near-threshold region at the boundary of the regime of magnetic self-insulation is investigated based on one-dimensional telegraph equations with electron losses. Numerical (difference) methods-specifically, a method of characteristics and a finite-difference scheme-are described and their properties and effectiveness are compared by analyzing the high-frequency modes.

Samokhin, A. A. [Troitsk Institute for Innovation and Fusion Research (Russian Federation)

2010-02-15T23:59:59.000Z

162

Path-sensitive analysis for reducing rollback overheads  

DOE Patents (OSTI)

A mechanism is provided for path-sensitive analysis for reducing rollback overheads. The mechanism receives, in a compiler, program code to be compiled to form compiled code. The mechanism divides the code into basic blocks. The mechanism then determines a restore register set for each of the one or more basic blocks to form one or more restore register sets. The mechanism then stores the one or more register sets such that responsive to a rollback during execution of the compiled code. A rollback routine identifies a restore register set from the one or more restore register sets and restores registers identified in the identified restore register set.

O'Brien, John K.P.; Wang, Kai-Ting Amy; Yamashita, Mark; Zhuang, Xiaotong

2014-07-22T23:59:59.000Z

163

ANUEADflM-31 Electric Power High-Voltage Transmission Lines:  

Office of Scientific and Technical Information (OSTI)

formulated fluid that is kept under high pressure. This fluid helps to dissipate the power loss heat generated by the conductors. The construction costs in 1991 dollars for...

164

LS Power Associates (ON Line - formerly known as SWIP-S) | Department...  

Office of Environmental Management (EM)

Impact ON Line is viewed as part of the transmission backbone that will bring wind and solar resources from Wyoming, Idaho, and Nevada to California and other major-load areas....

165

Effects of un-transposed UHV transmission line on fault analysis of power systems  

Science Journals Connector (OSTI)

The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method...

Anning Wang ???; Qing Chen ? ?; Zhanping Zhou ???

2008-06-01T23:59:59.000Z

166

SunLine Transit Agency Hydrogen-Powered Transit Buses: Third Evaluation Report and Appendices  

Energy.gov (U.S. Department of Energy (DOE))

This report describes operations at SunLine Transit Agency for a protoype fuel cell bus, a prototype hydrogen hybrid interal combustion engine bus, and five new compressed natural gas buses.

167

Notice of Intent to Prepare an Environmental Impact Statement for the Proposed Sutter Power Plant and Transmission Line Project, California  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 2 Federal Register / Vol. 63, No. 30 / Friday, February 13, 1998 / Notices taken, but will not serve to make protestants parties to the proceeding. Any person wishing to become a party must file a motion to intervene. Copies of his filing are on file with the Commission and are available for public inspection in the Public Reference Room. David P. Boergers, Acting Secretary. [FR Doc. 98-3659 Filed 2-12-98; 8:45 am] BILLING CODE 6717-01-M DEPARTMENT OF ENERGY Western Area Power Administration Notice of Intent To Prepare an Environmental Impact Statement for the Proposed Sutter Power Plant and Transmission Line Project, California AGENCY: Western Area Power Administration, DOE. ACTION: Notice of intent to prepare an Environmental Impact Statement. SUMMARY: In accordance with Section

168

446 IEEE JOURNAL OF SOLID-STATE CIRCUITS, VOL. 43, NO. 2, FEBRUARY 2008 A Low-Power SRAM Using Bit-Line  

E-Print Network (OSTI)

propose a new low-power SRAM using bit-line Charge Recycling (CR-SRAM) for the write operation to invert the state of the internal nodes of the SRAM cell in write operation. A low-power SRAM using446 IEEE JOURNAL OF SOLID-STATE CIRCUITS, VOL. 43, NO. 2, FEBRUARY 2008 A Low-Power SRAM Using Bit

Mahmoodi, Hamid

169

ELF field in the proximity of complex power line configuration measurement procedures  

Science Journals Connector (OSTI)

......This was intended to set out the basic principles for promotion of scientific research...continuous area monitor station, powered by photovoltaic cells and remotely queried using a GSM...Radiation Dosage Radiation Monitoring methods...

M. Benes; M. Comelli; R. Villalta

2006-06-01T23:59:59.000Z

170

DOE-HDBK-1143-2001; Radiological Control Training for Supervisors - Overheads  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Control Training for Supervisors Control Training for Supervisors DOE-HDBK-1143-2001 Overheads Office of Environment, Safety & Health U.S. Department of Energy Radiological Control Training for Supervisors DOE-HDBK-1143-2001 Overheads This page intentionally left blank. ii OT 1.1 DOE-HDBK-1143-2001 Overhead 1.1 Regulatory Documents Objectives: * Identify the hierarchy of regulatory documents. * Define the purposes of 10 CFR Parts 820, 830 and 835. * Define the purpose of the DOE Radiological Control Standard. OT 1.2 DOE-HDBK-1143-2001 Overhead 1.2 Regulatory Documents (cont.) Objectives: * Define the terms

171

Ecological benefits of dc power transmission  

SciTech Connect

The environmental effects of dc overhead transmission lines are examined. The major effects of ac and dc transmission lines are compared. Dc lines have advantages compared to ac lines in terms of electrical safety for people under the lines, biological effects, corona losses, and clearance width.

Kutuzova, N. B. [JSC 'NIIPT' (Russian Federation)

2011-05-15T23:59:59.000Z

172

Effective Methods in Reducing Communication Overheads in Solving  

NLE Websites -- All DOE Office Websites (Extended Search)

0/2002 Yun (Helen) He, GHC2002 1 0/2002 Yun (Helen) He, GHC2002 1 Effective Methods in Reducing Communication Overheads in Solving PDE Problems on Distributed-Memory Computer Architectures Chris Ding and Yun (Helen) He Lawrence Berkeley National Laboratory 10/10/2002 Yun (Helen) He, GHC2002 2 Outline n Introduction n Traditional Method n Ghost Cell Expansion (GCE) Method n GCE Algorithm n Diagonal Communication Elimination (DCE) Technique n Analysis of GCE Method n Message Volume n Communication Time n Memory Usage and Computational Cost n Performance n Test Problem n Test Results n Conclusions 10/10/2002 Yun (Helen) He, GHC2002 3 Background n On a distributed system, each processor holds a problem

173

Tests with a line-commutated converter as a variable inductive load on the Bonneville Power Administration transmission system  

SciTech Connect

A twelve-pulse, line-commutated converter, with a steady-state rating of 2.5 kV and 5.5 kA, formerly used for charging and discharging a superconducting magnet, was reconfigured as a static reactive power load. Tests staged at the Tacoma, WA, substation of the Bonneville Power Administration (BPA) revealed that the converter could be used as a variable inductive load, provided a stable current controller was installed. The unit was modulated as a variable VAR load following a sinusoidal VAR demand signal with an amplitude up to 14.8 MVAR. The total losses at maximum VAR output were 370 kW. This paper explains the necessary modifications of the converter to operate as a variable reactive load. Measured current waveshapes are analyzed. The effects of such a load on the BPA transmission system are presented.

Boenig, H.J.; Hauer, J.F.; Nielsen, R.G.

1986-01-01T23:59:59.000Z

174

Bonneville Power Administration Kangley-Echo Lake Transmission Line Project Record of Decision (DOE/EIS-0317) (7/21/03)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Bonneville Power Administration Bonneville Power Administration Kangley-Echo Lake Transmission Line Project Record of Decision Decision The Bonneville Power Administration (BPA) has decided to construct the proposed Kangley-Echo Lake Transmission Line Project in King County, Washington. BPA has decided to implement the Proposed Action (Alternative 1) identified in the Kangley-Echo Lake Transmission Line Project Final Environmental Impact Statement (DOE/EIS-0317-S1, June 2003). This decision is made thirty (30) days after publication of the notice for a final EIS (June 20, 2003) in the Federal Register. The Proposed Action consists of constructing a new 500-kilovolt (kV) transmission line from a tap point on an existing 500-kV line near Kangley, Washington, to BPA's Echo Lake

175

Application for Presidential Permit OE Docket No. PP-398 Minnesota Power- Great Northern Transmission Line: Amended Letter to New Border Crossing  

Energy.gov (U.S. Department of Energy (DOE))

Minnesota Power, an operating division of ALLETE, Inc., has submitted an amended application for a Presidential permit to construct, operate, maintain, and connect an electric transmission line across the United States border with Canada.

176

Modelling of a smart micro grid with renewable energy for rural area based on power line communication  

Science Journals Connector (OSTI)

Renewable energy conversion systems are main factor driving research on smart grid technology. Smart grid represents the paradigm to enable highly efficient power generation, transmission, distribution and consumption from the source to consumer. Bangladesh is facing energy crisis like other developing countries. High energy demands and environmental concerns force the transformation of existing power grid into smart micro grid. This paper proposes power line communication-based (PLC) platform on dynamic demand response and distributed generation including renewable power generation management approach in the context of smart micro grid model for residential and industrial consumptions. The implementation of smart micro grid to a rural area promotes the utilisation of renewable resources such as solar and wind energy. In this model, deployed PLC networks, data management system to integrate sensors, switchgears, transformers and other utility devices are used to interconnect smart homes to smart grids. Analytical results show the effectiveness of the proposed system to optimise residential renewable energy generation and smart meters to improve electrical grid control and energy conservation system.

Md. Atikur Rahman Sarker; Ken Nagasaka

2013-01-01T23:59:59.000Z

177

EIS-0005-FS: Bonneville Power Administration Proposed FY 1979 Program, Facility Location on Supplement, Southwest Oregon Area Service, Buckley-Summer Lake 500 kV Line, Supplemental  

Energy.gov (U.S. Department of Energy (DOE))

This Bonneville Power Administration document assesses the environmental impacts of constructing transmission facilities, which will coordinate with the Midpoint-Malin 500-kV line to be constructed by the Pacific Power and Light (PP&L) Company. The proposed action includes the construction of the 1.56-mile Buckley-Summer Lake 500-kV transmission line; the proposed Buckley Substation near Maupin, Oregon; and the proposed Summer Lake Substation near Silver Lake, Oregon.

178

Record of Decision for the Interconnection of the Sutter Power Project With the Western Area Power Administration's Keswick-Elverta/Olinda-Elverta 230-Kilovolt Double-Circuit Transmission Line, June 15, 1999  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

41 41 Federal Register / Vol. 64, No. 114 / Tuesday, June 15, 1999 / Notices DEPARTMENT OF ENERGY Western Area Power Administration Record of Decision for the Interconnection of the Sutter Power Project With the Western Area Power Administration's Keswick-Elverta/ Olinda-Elverta 230-Kilovolt Double- Circuit Transmission Line AGENCY: Western Area Power Administration, DOE. ACTION: Record of decision. SUMMARY: The Western Area Power Administration (Western) prepared this Record of Decision in response to a request submitted to Western for a direct interconnection of Calpine Corporation's (Calpine) proposed Sutter Power Project (SPP) with Western's electric transmission system. In response to this request, Western completed an Interconnection Feasibility Study that determined that

179

A power line impedance spectrum analyzer using real-time digital signal processing  

E-Print Network (OSTI)

. The subscript on each source corresponds to the harmonic generated by that source and all sources were set to an amplitude of O. lmA. The output files obtained from a transient analysis were then transferred to Matlab, and impedance spectrums were generated... Harmonic Number Figure 12 Simulated lmH Load Next the power network was simulated both with and without the attachment of the non-linear load. The voltage across the linear load was measured and plotted in the frequency domain using Matlab. Figure 13...

Margolis, Michael G

2012-06-07T23:59:59.000Z

180

Methodology for Preparing an Oral Presentation of a Scientific Paper (I assume the talk is organized around slides/overheads)  

E-Print Network (OSTI)

is organized around slides/overheads) 1) Read the paper 2) Take whatever steps necessary to ensure that you constraints on your talk (time, method of presentation, etc.) 5) Determine how many slides/overheads you can use (The ACS recommends spending at least 2 minutes on each slide/overhead)) 6) Determine the levels

Dibble, Theodore

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Demonstrating Heat Changes on the Overhead Projector with a Projecting Thermometer  

Science Journals Connector (OSTI)

Demonstrating Heat Changes on the Overhead Projector with a Projecting Thermometer ... Demonstrations that provide dramatic heat changes aredescribed, including chemical reactions , dissolving of solutes andsimulation of flameless ration heaters and commercial hot and cold packs. ...

Chinhyu Hur; Sally Solomon; Christy Wetzel

1998-01-01T23:59:59.000Z

182

Combined isomerization of overhead cuts of straight-run naphtha and reformate  

Science Journals Connector (OSTI)

Technology was developed for combined isomerization of IBP-85C overhead cuts of straight-run naphtha and reformate to reduce the benzene content in automotive gasolines. In comparison to the traditional technolo...

Nguen Van Ty

2008-07-01T23:59:59.000Z

183

The EOP Visualization Module Integrated into the Plasma On-Line Nuclear Power Plant Safety Monitoring and Assessment System  

SciTech Connect

An ambitious project to replace the unit information systems (UISs) at the Hungarian Paks nuclear power plant was started in 1998-99. The basic aim of the reconstruction project is to install a modern, distributed UIS architecture on all four Paks VVER-440 units. The new UIS includes an on-line plant safety monitoring and assessment system (PLASMA), which contains a critical safety functions monitoring module and provides extensive operator support during the execution of the new, symptom-oriented emergency operating procedures (EOPs). PLASMA includes a comprehensive EOP visualization module, based on the COPMA-III procedure-handling software developed by the Organization for Economic Cooperation and Development, Halden Reactor Project. Intranet technology is applied for the presentation of the EOPs with the use of a standard hypertext markup language (HTML) browser as a visualization tool. The basic design characteristics of the system, with a detailed description of its user interface and functions of the new EOP display module, are presented.

Hornaes, Arne [Organization for Economic Cooperation and Development (France); Hulsund, John Einar [Organization for Economic Cooperation and Development (France); Vegh, Janos [KFKI Atomic Energy Research Institute (Hungary); Major, Csaba [KFKI Atomic Energy Research Institute (Hungary); Horvath, Csaba [KFKI Atomic Energy Research Institute (Hungary); Lipcsei, Sandor [KFKI Atomic Energy Research Institute (Hungary); Kapocs, Gyoergy [Paks Nuclear Power Plant Ltd. (Hungary)

2001-08-15T23:59:59.000Z

184

EIS-0442: Reauthorization of Permits, Maintenance, and Vegetation Management on Western Area Power Administration Transmission Lines on Forest Service Lands, Colorado, Nebraska, and Utah  

Energy.gov (U.S. Department of Energy (DOE))

This EIS is being prepared jointly by DOEs Western Area Power Administration and the U.S. Forest Service. The EIS evaluates the potential environmental impacts of Westerns proposed changes to vegetation management along its transmission line rights-of-way on National Forest System lands in Colorado, Utah, and Nebraska.

185

EIS-0032: 500 kV International Transmission Line NSP-TR-1, Forbes, Minnesota to Manitoba, Canada, Northern States Power Company  

Energy.gov (U.S. Department of Energy (DOE))

The Economic Regulatory Administration developed this EIS to evaluate the environmental impacts of a 500-kilovolt transmission line proposed by the Northern States Power Company to provide a transmission facility for the exchange of electrical energy between Canada and the United States.

186

The Bottom Line Space@Penn Upgrade  

E-Print Network (OSTI)

The Bottom Line Space@Penn Upgrade Coming Soon! A project is underway to upgrade the current that allows designated users in the field to update certain elements of their space. This project, whose: Grants & Projects ­ Used for invoice generation, overhead and revenue recognition, and award and project

Sharp, Kim

187

Configurability of performance and overheads in flash management  

Science Journals Connector (OSTI)

Flash memory has been widely considered as a good alternative for storage system implementations because it offers superior vibration tolerance and power efficiency, compared to hard-disks. Because of its unique characteristics, direct applications of ...

Tei-Wei Kuo; Jen-Wei Hsieh; Li-Pin Chang; Yuan-Hao Chang

2006-01-01T23:59:59.000Z

188

Nonlinear control of a coupled PDE/ODE system modeling a switched power converter with a transmission line  

E-Print Network (OSTI)

with a transmission line Jamal Daafouz, Marius Tucsnak and Julie Valein Avril 2014 Abstract We consider an infinite dimensional system modeling a boost converter connected to a load via a transmission line. The governing.tucsnak@univ-lorraine.fr, julie.valein@univ-lorraine.fr 1 #12;converters connected to transmission lines is a very difficult task

Valein, Julie - Institut de Mathématiques ?lie Cartan, Université Henri Poincaré

189

Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments  

SciTech Connect

Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global thermal and mixed-field thermal neutron sensitivities derived from measurements performed at the RA-6 were compared and no significant differences were found. Global RA-6-based thermal neutron sensitivity showed agreement with pure thermal neutron sensitivity measurements performed in the RA-3 spectrum. Additionally, the detector response proved nearly unchanged by differences in neutron spectra from real (RA-6 BNCT beam) and ideal (considered for calibration calculations at RA-3) neutron source descriptions. The results confirm that the special design of the Rh SPND can be considered as having a pure thermal response for neutron spectra with epithermal-to-thermal flux ratios up to 12%. In addition, the linear response of the detector to thermal flux allows the use of a mixed-field thermal neutron sensitivity of 1.95 {+-} 0.05 x 10{sup -21} A n{sup -1}{center_dot}cm{sup 2}{center_dot}s. This sensitivity can be used in spectra with up to 21% epithermal-to-thermal flux ratio without significant error due to epithermal neutron and gamma induced effects. The values of the measured fluxes in clinical applications had discrepancies with calculated results that were in the range of -25% to +30%, which shows the importance of a local on-line independent measurement as part of a treatment planning quality control system. Conclusions: The usefulness of the CNEA Rh SPND for the on-line local measurement of thermal neutron flux on BNCT patients has been demonstrated based on an appropriate neutron spectra calibration and clinical applications.

Miller, Marcelo E.; Sztejnberg, Manuel L.; Gonzalez, Sara J.; Thorp, Silvia I.; Longhino, Juan M.; Estryk, Guillermo [Comision Nacional de Energia Atomica, Av. del Libertador 8250, Ciudad de Buenos Aires 1429 (Argentina); Comision Nacional de Energia Atomica, Av. del Libertador 8250, Ciudad de Buenos Aires 1429, Argentina and CONICET, Av. Rivadavia 1917, Ciudad de Buenos Aires 1033 (Argentina); Comision Nacional de Energia Atomica, Av. del Libertador 8250, Ciudad de Buenos Aires 1429 (Argentina)

2011-12-15T23:59:59.000Z

190

Economics of design and operation of overhead electric distribution systems  

E-Print Network (OSTI)

failures where bare conductors have been used, than on lines under the same operating conditions built of weather-proof conductor. k9 The area of the conductor exoosed to viind and ice, loading nas been re- duced by, omitting the insulation without... ? dead end, galvanized, zith cotter key. This clevis must, fit both $506 and O. B. X. H. strain insulators under 10, 000 pound tension. 19. Connectors ? 3 ? bolt, solderless, bronze clamp. 20. Connectors ? aluminum, 2" clamp. 21. Ground rods...

Cox, Carl Clarence

2012-06-07T23:59:59.000Z

191

Solar aided power generation of a 300MW lignite fired power plant combined with line-focus parabolic trough collectors field  

Science Journals Connector (OSTI)

Abstract Nowadays, conventional coal or gas fired power plants are the dominant way to generate electricity in the world. In recent years there is a growth in the field of renewable energy sources in order to avoid the threat of climate change from fossil fuel combustion. Solar energy, as an environmental friendly energy source, may be the answer to the reduction of global CO2 emissions. This paper presents the concept of Solar Aided Power Generation (SAPG), a combination of renewable and conventional energy sources technologies. The operation of the 300MW lignite fired power plant of Ptolemais integrated with a solar field of parabolic trough collectors was simulated using TRNSYS software in both power boosting and fuel saving modes. The power plant performance, power output variation, fuel consumption and CO2 emissions were calculated. Furthermore, an economic analysis was carried out for both power boosting and fuel saving modes of operation and optimum solar contribution was estimated.

G.C. Bakos; Ch. Tsechelidou

2013-01-01T23:59:59.000Z

192

Summit-Watertown transmission line project, South Dakota. Final Environmental Assessment  

SciTech Connect

The Western Area Power Administration (Western) needs to rebuild the existing Summit-Watertown 115-kV transmission line, located in northeastern South Dakota, and western Minnesota. Nearly 60 percent of the existing facility was replaced in 1965 after severe ice-loading broke structures and wires. Because of the extensive loss of the line, surplus poles had to be used to replace the damaged H-frame structures. These were of varying sizes, causing improper structure loading. Additionally, the conductors and overhead shield wires have been spliced in numerous places. This provides additional space on these wires for icing and wind resistance, which in turn create problems for reliability. Finally, a progressive fungal condition has weakened the poles and, along with the improper loading, has created an unsafe condition for maintenance personnel and the general public.

Not Available

1993-12-01T23:59:59.000Z

193

Geotechnical, Geological, and Hydrologic Characterization of a 52km Electrical Power Transmission Line Alignment Route in Southeastern Nigeria  

Science Journals Connector (OSTI)

A 132 kVA electrical transmission line has been proposed to connect the towns ... hydrological study was performed to geotechnically characterize the route alignment and to provide data for design of the foundati...

A. O. Ilori; N. U. Essien; A. E. Edet

2010-11-01T23:59:59.000Z

194

Measuring the Overhead of Intel C++ CnC over TBB for Gauss-Jordan Elimination  

E-Print Network (OSTI)

Measuring the Overhead of Intel C++ CnC over TBB for Gauss-Jordan Elimination Peiyi Tang Department only by the data dependencies be- tween the tasks. Both Intel C++ Concurrent Col- lections (CnC algorithm and implemented it in TBB. We compare the performances of TBB and CnC, which is built on top

Tang, Peiyi

195

A Novel Low-overhead Delay Testing Technique for Arbitrary Two-Pattern Test Application  

E-Print Network (OSTI)

in manufacturing test to complement stuck-at-fault testing. Design- for-testability techniques, such as enhanced as an alternative to the enhanced scan based delay fault testing method, with significantly less design overhead testing, transition in the state inputs is induced by shifting the scan values by one bit position

Paris-Sud XI, Université de

196

A NegativeOverhead, SelfTimed Pipeline Brian D. Winters and Mark R. Greenstreet  

E-Print Network (OSTI)

A Negative­Overhead, Self­Timed Pipeline Brian D. Winters and Mark R. Greenstreet Department a novel variation of wave pipelining that we call ``surfing.'' In previous wave pipelined designs, timing variation of wave pipelin­ ing called ``surfing.'' In surfing pipelines, a timing pulse is propagated along

Greenstreet, Mark

197

In-line continuous sizing of biomass particles in gas-solid two-phase flow at a biomass-fired power plant  

Science Journals Connector (OSTI)

Gas-solid two-phase flows are widely seen in many industrial processes. A good exampleis the pneumatically conveyed pulverised fuel flow in the power generation industry. As a significant renewable fuel source biomass has been widely adopted in electrical power generation. The particle size distribution of pneumatically conveyed biomass correlates closely with combustion efficiency and pollutant emissions and should therefore be monitored on anin-line continuous basis. In this paper an integrated instrumentation system using both a piezoelectric sensorand anelectrostatic sensor arrayis proposed to measure the size distribution and flow velocity of biomass particles. A prototype system was tested on a 250mm bore pipe at a biomass-fired power plantand its performance has been evaluated under industrial conditions.

2014-01-01T23:59:59.000Z

198

Coordination of Transmission Line Transfer Capabilities  

E-Print Network (OSTI)

Coordination of Transmission Line Transfer Capabilities Final Project Report Power Systems since 1996 PSERC #12;Power Systems Engineering Research Center Coordination of Transmission Line Summary The maximum power that can be transferred over any transmission line, called the transfer capacity

199

Design and Validation of a Mobile Robot for PowerDesign and Validation of a Mobile Robot for PowerDesign and Validation of a Mobile Robot for PowerDesign and Validation of a Mobile Robot for Power Line Inspection and MaintenanceLine Inspection and Mainten  

E-Print Network (OSTI)

of the prototype thorough validation. Working on live lines, up to 735 kV and 1,000 A, means that the technology inspection and maintenance on its transmission lines [9]. From the very beginning, the key objectiveSystem RequirementsSystem RequirementsSystem Requirements A complete review of transmission line components

Paris-Sud XI, Université de

200

Development of a hybrid intelligent system for on-line real-time monitoring of nuclear power plant operations  

E-Print Network (OSTI)

A nuclear power plant (NPP) has an intricate operational domain involving systems, structures and components (SSCs) that vary in scale and complexity. Many of the large scale SSCs contribute to the lost availability in the ...

Yildiz, Bilge, 1976-

2003-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Design of a laser-induced breakdown spectroscopy system for on-line quality analysis of pulverized coal in power plants  

SciTech Connect

It is vitally important for a power plant to determine the chemical composition of coal prior to combustion in order to obtain optimal boiler control. In this work, a fully software-controlled laser-induced breakdown spectroscopy (LIBS) system comprising a LIBS apparatus and sampling equipment has been designed for possible application to power plants for on-line quality analysis of pulverized coal. Special attention was given to the LIBS system, the data processing methods (especially the normalization with Bode Rule/DC Level) and the specific settings (the software-controlled triggering source, high-pressure gas cleaning device, sample preparation module, sampling module, etc.), which gave the best direct measurement for C, H, Si, Na, Mg, Fe, Al, and Ti with measurement errors less than 10% for pulverized coal. Therefore, the apparatus is accurate enough to be applied to industries for on-line monitoring of pulverized coal. The method of proximate analysis was also introduced and the experimental error of A(ad) (Ash, 'ad' is an abbreviation for 'air dried') was shown in the range of 2.29 to 13.47%. The programmable logic controller (PLC) controlled on-line coal sampling equipment, which is designed based upon aerodynamics, and is capable of performing multipoint sampling and sample-preparation operation.

Yin, W.B.; Zhang, L.; Dong, L.; Ma, W.G.; Jia, S.T. [Shanxi Agricultural University, Taiyuan (China)

2009-08-15T23:59:59.000Z

202

Wojciech.Wiechowski@wtwps.com POWER SYSTEM TECHNICAL PERFORMANCE ISSUES  

E-Print Network (OSTI)

underground transmission project are identified. Cable line modeling and model verification techniques of new overhead lines (OHL), transmission utilities consider installation of HV/EHV AC underground cables compensation installed along the route. At present, the longest 500 kV AC cable line is operated in Japan (40

Bak, Claus Leth

203

Western Area Power Administration, Desert Southwest Region Parker-Gila 161-kV Transmission Line Maintenance, Cross Arm  

NLE Websites -- All DOE Office Websites (Extended Search)

Parker-Gila 161-kV Transmission Line Maintenance, Cross Arm Parker-Gila 161-kV Transmission Line Maintenance, Cross Arm Replacements at Structure 0/7 - Continuation Sheet Special Conditions Biological Resources 1. To avoid impacts to nesting birds, project activities will be scheduled between August 1 and February 15, as feasible. Crews shall not cause injury or death to nesting birds, active nests, eggs, or nestlings. If evidence of a nesting bird is found in the project area, crews shall immediately stop work in that area until Western's Environmental Group has been contacted. 2. A qualified biologist will be present during all project activities and serve as the project's Biological Monitor. The Biological Monitor will be authorized by Western to temporarily halt construction activity if needed to prevent harm to desert tortoise. The Biological Monitor's

204

PEV-based P-Q Control in Line Distribution Networks with High Requirement for Reactive Power Compensation  

E-Print Network (OSTI)

impact of distribution level wind turbines. Our design is based on a nonlinear power flow analysis of wind turbines to support their induction load to avoid generator voltage excursion. Note that, although-sized wind turbines in large wind farms [1], the smaller wind turbines that are used at the distribution

Huang, Jianwei

205

Characterization Results For The 2013 HTF 3H Evaporator Overhead Samples  

SciTech Connect

This report tabulates the radiochemical analysis of the 3H evaporator overhead sample for {sup 137}Cs, {sup 90}Sr, and {sup 129}I to meet the requirements in the Effluent Treatment Project (ETP) Waste Acceptance Criteria (WAC) (rev. 6). This report identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. All data was found to be within the ETP WAC (rev. 6) specification for the Waste Water Collection Tanks (WWCT).

Washington, A. L. II

2013-12-04T23:59:59.000Z

206

Utility Lines and Facilities (Montana)  

Energy.gov (U.S. Department of Energy (DOE))

These regulations apply to the construction of utility and power lines and facilities. They address the use of public right-of-ways for such construction, underground power lines, and construction...

207

1. This research was supported by General Motors R&D Center. Digest of Papers: IEEE International On-Line Testing Workshop, 1996, pp. 164-167.  

E-Print Network (OSTI)

of this technique. 1 Introduction There are four primary parameters to be considered in the design of any on-line overhead. On-line BIST is usually implemented with the goals of complete error coverage, near-minimal error On-Line Testing Workshop, 1996, pp. 164-167. Abstract This paper briefly reviews on-line built

Al-Asaad, Hussain

208

Demonstration of a Novel Synchrophasor-based Situational Awareness System: Wide Area Power System Visualization, On-line Event Replay and Early Warning of Grid Problems  

SciTech Connect

Since the large North Eastern power system blackout on August 14, 2003, U.S. electric utilities have spent lot of effort on preventing power system cascading outages. Two of the main causes of the August 14, 2003 blackout were inadequate situational awareness and inadequate operator training In addition to the enhancements of the infrastructure of the interconnected power systems, more research and development of advanced power system applications are required for improving the wide-area security monitoring, operation and planning in order to prevent large- scale cascading outages of interconnected power systems. It is critically important for improving the wide-area situation awareness of the operators or operational engineers and regional reliability coordinators of large interconnected systems. With the installation of large number of phasor measurement units (PMU) and the related communication infrastructure, it will be possible to improve the operators situation awareness and to quickly identify the sequence of events during a large system disturbance for the post-event analysis using the real-time or historical synchrophasor data. The purpose of this project was to develop and demonstrate a novel synchrophasor-based comprehensive situational awareness system for control centers of power transmission systems. The developed system named WASA (Wide Area Situation Awareness) is intended to improve situational awareness at control centers of the power system operators and regional reliability coordinators. It consists of following main software modules: Wide-area visualizations of real-time frequency, voltage, and phase angle measurements and their contour displays for security monitoring. Online detection and location of a major event (location, time, size, and type, such as generator or line outage). Near-real-time event replay (in seconds) after a major event occurs. Early warning of potential wide-area stability problems. The system has been deployed and demonstrated at the Tennessee Valley Authority (TVA) and ISO New England system using real-time synchrophasor data from openPDC. Apart from the software product, the outcome of this project consists of a set of technical reports and papers describing the mathematical foundations and computational approaches of different tools and modules, implementation issues and considerations, lessons learned, and the results of lidation processes.

Rosso, A.

2012-12-31T23:59:59.000Z

209

Wind Power  

NLE Websites -- All DOE Office Websites (Extended Search)

Wind Power As the accompanying map of New Mexico shows, the best wind power generation potential near WIPP is along the Delaware Mountain ridge line of the southern Guadalupe...

210

Fiber optic sensors for nuclear power plant applications  

SciTech Connect

Studies have been carried out for application of Raman Distributed Temperature Sensor (RDTS) in Nuclear Power Plants (NPP). The high temperature monitoring in sodium circuits of Fast Breeder Reactor (FBR) is important. It is demonstrated that RDTS can be usefully employed in monitoring sodium circuits and in tracking the percolating sodium in the surrounding insulation in case of any leak. Aluminum Conductor Steel Reinforced (ACSR) cable is commonly used as overhead power transmission cable in power grid. The suitability of RDTS for detecting defects in ACSR overhead power cable, is also demonstrated.

Kasinathan, Murugesan; Sosamma, Samuel; BabuRao, Chelamchala; Murali, Nagarajan; Jayakumar, Tammana [Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamil Nadu-603102 (India)

2012-05-17T23:59:59.000Z

211

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers  

E-Print Network (OSTI)

Total Power for Server Power Cooling Module Power (kW) (Cooling is the amount of cooling power removed from the dataratio of total cooling power to the cooling transported by

Xu, TengFang T.

2009-01-01T23:59:59.000Z

212

E-Print Network 3.0 - ac transmission lines Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

lines Search Powered by Explorit Topic List Advanced Search Sample search results for: ac transmission lines...

213

E-Print Network 3.0 - astrocytoma cell lines Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

lines Search Powered by Explorit Topic List Advanced Search Sample search results for: astrocytoma cell lines...

214

E-Print Network 3.0 - adenocarcinoma cell lines Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

lines Search Powered by Explorit Topic List Advanced Search Sample search results for: adenocarcinoma cell lines...

215

E-Print Network 3.0 - ac transmission line Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

line Search Powered by Explorit Topic List Advanced Search Sample search results for: ac transmission line...

216

Application for Presidential Permit OE Docket No. PP-362 Champlain Hudson Power Express, Inc.: Record of Decision for Issuing a Presidential Permit for the CHPE Transmission Line Project: Federal Register Notice, Volume 79, No. 190- Oct. 1, 2014  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy (DOE) announces its decision to issue a Presidential permit to Champlain Hudson Power Express, Inc. (CHPEI), to construct, operate, maintain, and connect an electric transmission line across the U.S./Canada border in the northeastern New York State.

217

Proposed amendment for Presidential Permit PP-63 and associated modifications to 500 kV international transmission line, Forbes, Minnesota to Manitoba, Canada Northern States Power Company. Final Environmental Assessment  

SciTech Connect

Northern States Power Company, (NSP), a Minnesota investor owned utility has applied to the Office of Fossil Energy, United States Department of Energy, to amend Presidential Permit PP-63 to allow for alterations to the 500 kV transmission line and as sedated facilities currently regulated by this permit. The alterations proposed for the 500 kV line owned by NSP are part of a long term effort sponsored by NSP to upgrade the existing NSP transmission system to allow for increased exchange of electricity with the Manitoba Hydro-Electric Board. Presidential Permit PP-63 authorized NSP to construct, connect, operate and maintain a 500 kV line at the United States/Canadian border approximately seven-and-a-half miles west of Warroad in Roseau County, Minnesota. This line connects with a 500 kV line owned and operated by the Manitoba Hydro-Electric Board (MHEB), which extends from Dorsey, Manitoba, Canada to the United States/Canadian border. NSP proposes to increase the electricity transfer capability of this transmission facility by constructing a new 80-acre substation on the existing 500 kV line in Roseau County, Minnesota, and upgrading the existing substation at Forbes, Minnesota. The proposed Roseau substation would contain two 41.5 ohm series capacitor banks. In addition, static VAR compensators are to be installed at the existing Forbes Substation. Approximately 5 acres would be added to the 30-acre Forbes site to house the additional equipment. No new lines would enter or exit the facility. NSP proposes to place the new Roseau Substation in service in May 1993 and to complete the upgrading of the Forbes Substation in March 1994. The primary, initial purpose of these modifications is to enable NSP to import 400 megawatts of electric power from MHEB during the summer months to meet peak electrical demand in the Minneapolis-St. Paul area. It is expected that this power transfer would begin in 1993.

Not Available

1992-02-01T23:59:59.000Z

218

Appointed BrOadcast (ABO): Reducing Routing Overhead in IEEE 802.11 Mobile Ad Hoc Networks  

E-Print Network (OSTI)

1 Appointed BrOadcast (ABO): Reducing Routing Overhead in IEEE 802.11 Mobile Ad Hoc Networks Chun-enhanced and standard IEEE 802.11 nodes can coexist in a MANET is also discussed. Keywords: mobile ad hoc network, promiscuous mode, broadcast, IEEE 802.11, routing. #12;2 1. Introduction In mobile ad hoc networks (MANETs

Chen, Sheng-Wei

219

Development and modification of a single overhead camshaft 4-valve 4-stroke 135 cc formula varsity race car engine  

Science Journals Connector (OSTI)

The engine that was chosen to be developed and modified is Yamaha LC 135 Single Overhead Camshaft (SOHC) 4-valve 4-stroke 135cc liquid-cooled engine. The engine selection is based on the specification, rule and regulation in UTeM Formula Varsity 2012 (FV 2012). The engine performance is determined by engine operating characteristics. The engine air flow affects the filtration, intake and exhaust systems. The heat from the engine rejected to the surrounding through the active cooling system which has radiator and fan. The selection of the engine is based on weighted decision matrix which consists of reliability, operating and maintenance cost, fuel consumption and weight. The score of the matrix is formulated based on relative weighted factor among the selections. It been compared between Yamaha LC 135 Single Overhead Camshaft (SOHC) 4-valve 4-stroke 135cc liquid-cooled engine, Honda Wave 125 X Air Cooled, 4 Cycle Engine Overhead Camshaft (OHC) and Suzuki Shogun RR 4 stroke air cooled Single Overhead Camshaft (SOHC). The modification is applied to the engine through the simulation and tuning of Capacitor Discharge Ignition (CDI).

M A Abdullah; N Tamaldin; H Rusnandi; T Manoharan; M A Samsir

2013-01-01T23:59:59.000Z

220

Notice of Intent to Prepare an Environmental Impact Statement for the proposed Griffith Power Plant and Transmission Line Project, Mojave County, AZ  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

96 96 Federal Register / Vol. 63, No. 64 / Friday, April 3, 1998 / Notices Metered Entities the ISO and Alta Power Generation, L.L.C., for acceptance by the Commission. The ISO states that this filing has been served on all parties listed on the official service list in Docket Nos. EC96- 19-003 and ER96-1663-003, including the California Public Service Commission. Comment date: April 9, 1998, in accordance with Standard Paragraph E at the end of this notice. 16. Allegheny Power Service Corp., on Behalf of Monongahela Power The Potomac Edison Company, and West Penn Power Company (Allegheny Power) [Docket No. ER98-2307-000] Take notice that on March 24, 1998, Allegheny Power Service Corporation on behalf of Monongahela Power Company, The Potomac Edison Company and West Penn Power

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Power blackouts likely  

Science Journals Connector (OSTI)

... generating stations switch off if they cannot transmit their power. As power stations and transmission substations were knocked out, power was shifted to lines further down the network, causing them ... a map of the United States containing more than 14,000 generating, transmission and distribution substations, and over 19,000 connecting power lines. ...

Philip Ball

2004-01-20T23:59:59.000Z

222

Line Projects  

NLE Websites -- All DOE Office Websites (Extended Search)

(PDCI) Upgrade Project Whistling Ridge Energy Project Line Rebuild, Relocation and Substation Projects Wind Projects Line Projects BPA identifies critical infrastructure and...

223

Proposed Project: Plains & Eastern Clean Line | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Section 1222 of the Energy Policy Act 2005 » Proposed Project: Plains & Section 1222 of the Energy Policy Act 2005 » Proposed Project: Plains & Eastern Clean Line Proposed Project: Plains & Eastern Clean Line On June 10, 2010, the Department of Energy published in the Federal Register a Request for Proposals (RFP) for New or Upgraded Transmission Line Projects Under Section 1222 of the Energy Policy Act (EPAct) of 2005. In response, Clean Line Energy Partners, LLC submitted an application for its Plains & Eastern Clean Line project. DOE has concluded that Clean Line's proposal was responsive to the RFP, and it is currently under consideration. The proposed Plains & Eastern Clean Line project (the proposed project) would include an overhead +/- 600 kV direct current electric transmission system and associated facilities with the capacity to deliver approximately

224

NEW ACCURATE FAULT LOCATION ALGORITHM FOR PARALLEL TRANSMISSION LINES.  

E-Print Network (OSTI)

??Electric power systems have been in existence for over a century. Electric power transmission line systems play an important role in carrying electrical power to (more)

Chaiwan, Pramote

2011-01-01T23:59:59.000Z

225

Dynamic Line Rating: Research and Policy Evaluation  

SciTech Connect

Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of electrical conductors to be increased based on local weather conditions. Overhead lines are conventionally given a conservative rating based on worst case scenarios. We demonstrate that observing the conditions in real time leads to additional capacity and safer operation. This paper provides a report of a pioneering scheme in the United States of America in which DLR has been applied. Thereby, we demonstrate that observing the local weather conditions in real time leads to additional capacity and safer operation. Secondly, we discuss limitations involved. In doing so, we arrive at novel insights which will inform and improve future DLR projects. Third, we provide a policy background and discussion to clarify the technologys potential and identifies barriers to the imminent adoption of dynamic line rating systems. We provide suggestions for regulatory bodies about possible improvements in policy to encourage adoption of this beneficial technology.

Jake P. Gentle; Kurt S. Myers; Michael R. West

2014-07-01T23:59:59.000Z

226

Help Line  

NLE Websites -- All DOE Office Websites (Extended Search)

Help Line Help Line Ombuds Help Line Committed to the fair and equitable treatment of all employees, contractors, and persons doing business with the Laboratory. Contact Ombuds Office (505)665-2837 Email Help Line (505) 667-9370 Fax (505) 667-3119 Map & Hours Help Line: (505) 667-9370 As an option to visiting the Ombuds office, we provide service through a telephone Help Line and email. The telephone Help Line is useful for individuals who have concerns and want advice or referral while preserving confidentiality and anonymity. Callers may remain anonymous and the Help Line does not have caller ID or other methods of identifying callers. The Help Line maintains the same level of confidentiality and neutrality as the other Ombuds services. The Ombuds Help Line is not for reporting emergencies or officially

227

Electric Transmission Line Flashover Prediction System  

E-Print Network (OSTI)

Center since 1996 PSERC #12;Power Systems Engineering Research Center Electric Transmission LineElectric Transmission Line Flashover Prediction System Ph.D. Thesis and Final Project Report Power@asu.edu Power Systems Engineering Research Center This is a project report from the Power Systems Engineering

228

Accident Investigation of the July 30, 2013, Electrical Fatality on the Bandon-Rogue No. 1 115kV Line at the Bonneville Power Administration  

Energy.gov (U.S. Department of Energy (DOE))

This report is an independent product of the Level I Accident Investigation Board appointed by Brad Bea, Chief Safety Officer, Bonneville Power Administration. The Board was appointed to perform a Level I Accident Investigation and to prepare an investigation report in accordance with Bonneville Power Administration Manual, Chapter 181, Accident Investigation and Reporting.

229

PROCEEDINGS THE INSTITUTION OF ELECTRICAL ENGINEERS  

E-Print Network (OSTI)

Introduction Despite new designs of pylons for overhead lines, and other innovations, the windPROCEEDINGS THE INSTITUTION OF ELECTRICAL ENGINEERS PowerVolume 116 Overhead-line oscillations of overhead lines, usually known as 'galloping'. The energy per cycle dissipated by the aerodynamic drag

Hunt, Julian

230

EIS-0486: Plains & Eastern Clean Line Transmission Project  

Energy.gov (U.S. Department of Energy (DOE))

This EIS will evaluate the potential environmental impacts of participating with Clean Line Energy Partners LLC (Clean Line) in the proposed Plains & Eastern Project. The proposed project would include an overhead 600 kilovolt (kV) high voltage direct current (HVDC) electric transmission system and associated facilities with the capacity to deliver approximately 3,500 megawatts (MW) primarily from renewable energy generation facilities in the Oklahoma Panhandle region to load-serving entities in the Mid-South and Southeast via an interconnection with the Tennessee Valley Authority (TVA).

231

On-line Self Error Detection with Equal Protection Against All Errors Mark G. Karpovsky, Konrad J. Kulikowski, Zhen Wang  

E-Print Network (OSTI)

On-line Self Error Detection with Equal Protection Against All Errors Mark G. Karpovsky, Konrad J and storage. We also present several design techniques for memories with self-error-detection based on the pro. The proposed robust codes require slightly larger overhead than standard and widely-used linear codes

Karpovsky, Mark

232

TITLE III EVALUATION REPORT FOR THE SURFACE AND SUBSURFACE POWER SYSTEM  

SciTech Connect

The objective of this evaluation is to provide recommendations to ensure consistency between the technical baseline requirements, baseline design, and the alternate constructed power system. Recommendations for resolving discrepancies between the alternate constructed power system, the technical baseline requirements, and the baseline design are included in this report. Cost and schedule estimates are provided for all recommended modifications. This report does not address items which do not meet current safety or code requirements. These items are identified to the CMO and immediate action is taken to correct the situation. The report does identify safety and code items for which the A/E is recommending improvements. The recommended improvements will exceed the minimum requirements of applicable code and safety guidelines. These recommendations are intended to improve and enhance the operation and maintenance of the facility. This Title III Evaluation Report (TER) does not include evaluation of surface electrical construction support facilities used to provide temporary construction power where the intent to remove such facilities when construction is completed such as tent storage buildings, shop buildings, fuel storage area etc. Furthermore, this TER does not include the extension of the existing overhead power lines to the booster pump station that was designed, installed, and is maintained by Nevada Test Site (NTS).

W.J. REED

1999-08-16T23:59:59.000Z

233

PF-OLA: A High-Performance Framework for Parallel On-Line Aggregation  

E-Print Network (OSTI)

On-line aggregation provides estimates to the final result of a computation during the actual processing. The user can stop the computation as soon as the estimate is accurate enough, typically early in the execution. This allows for the interactive data exploration of the largest datasets. In this paper we introduce the first framework for parallel on-line aggregation in which the estimation does not incur any overhead on top of the actual execution. We define a generic interface to express any estimation model that abstracts completely the execution details. We design a novel estimator specifically targeted at parallel on- line aggregation. When executed by the framework over an 8TB TPC-H instance, the estimator provides accurate confidence bounds early in the execution even when the cardinality of the final result is seven orders of magnitude smaller than the dataset size and without incurring any overhead.

Qin, Chengjie

2012-01-01T23:59:59.000Z

234

EIS-0502: Hot Springs to Anaconda Transmission Line Rebuild Project...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Hot Springs to Anaconda Transmission Line Rebuild Project, Montana EIS-0502: Hot Springs to Anaconda Transmission Line Rebuild Project, Montana SUMMARY DOE's Bonneville Power...

235

EA-1891: Alvey-Fairview Transmission Line Rebuild Project, Oregon...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: Alvey-Fairview Transmission Line Rebuild Project, Oregon EA-1891: Alvey-Fairview Transmission Line Rebuild Project, Oregon Summary Bonneville Power Administration prepared an EA...

236

Northwest, the Bonneville Power  

NLE Websites -- All DOE Office Websites (Extended Search)

by a similar event. Overgrown trees came in contact with high-voltage transmission lines, causing a protective shutdown that created cascading power outages across the...

237

Ultra-scale vehicle tracking in low spatial-resolution and low frame-rate overhead video  

SciTech Connect

Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery either in real-time or quickly on-demand is very desirable. With this ability we can begin to answer a number of interesting questions such as, what are normal traffic patterns in a particular region or where did that truck come from? There are many challenges associated with processing this type of data, some of which we will address in the paper. Wide-field image sequences are very large with many thousands of pixels on a side and are characterized by lower resolutions (e.g. worse than 0.5 meters/pixel) and lower frame rates (e.g. a few Hz or less). The objects in the scenery can vary in size, density, and contrast with respect to the background. At the same time the background scenery provides a number of clutter sources both man-made and natural. We describe our current implementation of an ultrascale capable multiple-vehicle tracking algorithm for overhead persistent surveillance imagery as well as discuss the tracking and timing performance of the currently implemented algorithm which is aimed at utilizing grayscale electrooptical image sequences alone for the track segment generation.

Carrano, C J

2009-05-20T23:59:59.000Z

238

Savings Through Power Quality  

E-Print Network (OSTI)

. Harmonics can be cause of inefficient distribution of power, power line carrier (PLC), egg. Clocks and Energy Management Systems (EMS). Finally, harmonics can cause utility meters, KW Demand and KWH consumption, to register false readings. Electro...

Mehrdad, M.

2005-01-01T23:59:59.000Z

239

Preventing power outages Power system contingency analysis on the GPU  

E-Print Network (OSTI)

problem. Moreover, the power system has to keep functioning properly even when a transmission line failsPreventing power outages Power system contingency analysis on the GPU To provide electricity generators, nuclear power plants, wind turbines, etc.) and a network of lines and cables to transmit

Vuik, Kees

240

2005 clean coal and power conference. Conference proceedings  

SciTech Connect

The theme of the conference was 'The paradox: today's coal technologies versus tomorrow's promise'. The sessions covered: today's technologies, tomorrow's potential; economic stability; energy security; transition to sustainable energy future; new coal power technologies leading to zero emission coal; existing power plants - improved performance through use of new technology; and carbon capture and storage R & D - challenges and opportunities. Some of the papers only consist of the viewgraphs/overheads.

NONE

2005-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

line, Pinal County, Arizona RECORD OF CATEGORICAL EXCLUSION DETERMINATION  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

along the existing along the existing Empire-EDS 11S-kV transmission line, Pinal County, Arizona RECORD OF CATEGORICAL EXCLUSION DETERMINATION A. Proposed Action: Western proposes to replace structures and upgrade to a double circuit 230-kV transmission line on its Empire-ED5 115-kV transmission line, within Western's existing right-of-way. This will include the rebuild of 9.2 miles of transmission line, replacing the H-frame structures with steel monopole structures with foundations, hardware and insulator replacement and adding a overhead ground-wire over the entire length of the project. Western will access the structure using crew trucks along the existing access roads. This work is necessary to maintain the safety and reliability of the bulk electrical system.

242

Big Bend-Witten Transmission Line Project  

NLE Websites -- All DOE Office Websites (Extended Search)

Big Bend-Witten Transmission Line Project The Western Area Power Administration (Western), an agency of the Department of Energy (DOE), has prepared a draft environmental...

243

Williston to Stateline Transmission Line Project  

NLE Websites -- All DOE Office Websites (Extended Search)

Williston to Stateline Transmission Line Project, ND The Western Area Power Administration (Western), an agency of the Department of Energy (DOE), has prepared an environmental...

244

Transmission line capital costs  

SciTech Connect

The displacement or deferral of conventional AC transmission line installation is a key benefit associated with several technologies being developed with the support of the U.S. Department of Energy`s Office of Energy Management (OEM). Previous benefits assessments conducted within OEM have been based on significantly different assumptions for the average cost per mile of AC transmission line. In response to this uncertainty, an investigation of transmission line capital cost data was initiated. The objective of this study was to develop a database for preparing preliminary estimates of transmission line costs. An extensive search of potential data sources identified databases maintained by the Bonneville Power Administration (BPA) and the Western Area Power Administration (WAPA) as superior sources of transmission line cost data. The BPA and WAPA data were adjusted to a common basis and combined together. The composite database covers voltage levels from 13.8 to 765 W, with cost estimates for a given voltage level varying depending on conductor size, tower material type, tower frame type, and number of circuits. Reported transmission line costs vary significantly, even for a given voltage level. This can usually be explained by variation in the design factors noted above and variation in environmental and land (right-of-way) costs, which are extremely site-specific. Cost estimates prepared from the composite database were compared to cost data collected by the Federal Energy Regulatory Commission (FERC) for investor-owned utilities from across the United States. The comparison was hampered because the only design specifications included with the FERC data were voltage level and line length. Working within this limitation, the FERC data were not found to differ significantly from the composite database. Therefore, the composite database was judged to be a reasonable proxy for estimating national average costs.

Hughes, K.R.; Brown, D.R.

1995-05-01T23:59:59.000Z

245

Reactive power compensating system  

DOE Patents (OSTI)

The reactive power of an induction machine is compensated by providing fixed capacitors on each phase line for the minimum compensation required, sensing the current on one line at the time its voltage crosses zero to determine the actual compensation required for each phase, and selecting switched capacitors on each line to provide the balance of the compensation required.

Williams, Timothy J. (Redondo Beach, CA); El-Sharkawi, Mohamed A. (Renton, WA); Venkata, Subrahmanyam S. (Seattle, WA)

1987-01-01T23:59:59.000Z

246

Underground Power Transmission  

Science Journals Connector (OSTI)

...The type of transmission line for a particular...will force rt transmission lines to be ground near...history of power transmission shows that d-c...characteristics of a d-c line, it is easy to...Best data fit III II I...

P. H. Rose

1970-10-16T23:59:59.000Z

247

Muehrcke's Lines  

Science Journals Connector (OSTI)

Figure 1. A 46-year-old woman with metastatic sarcoma who had been treated with five cycles of doxorubicin, ifosfamide, and mesna chemotherapy presented with two symmetrical, horizontal white lines on all of her fingernails but not on her toenails. A diagnosis of ...

Morrison-Bryant M.; Gradon J.D.

2007-08-30T23:59:59.000Z

248

Beau's Lines  

Science Journals Connector (OSTI)

Figure 1. A 62-year-old woman received six cycles of docetaxel chemotherapy during a six-month period for recurrent metastatic breast cancer. She had completed treatment four weeks before this photograph was taken. Six evenly spaced, transverse lines were noted on ...

Mortimer N.J.; Mills J.

2004-10-21T23:59:59.000Z

249

Power Projects  

NLE Websites -- All DOE Office Websites (Extended Search)

Power Projects Power Projects Contact SN Customers Environmental Review-NEPA Operations & Maintenance Planning & Projects Power Marketing Rates You are here: SN Home page > About SNR Power Projects Central Valley: In California's Central Valley, 18 dams create reservoirs that can store 13 million acre-feet of water. The project's 615 miles of canals irrigate an area 400 miles long and 45 miles wide--almost one third of California. Powerplants at the dams have an installed capacity of 2,099 megawatts and provide enough energy for 650,000 people. Transmission lines total about 865 circuit-miles. Washoe: This project in west-central Nevada and east-central California was designed to improve the regulation of runoff from the Truckee and Carson river systems and to provide supplemental irrigation water and drainage, as well as water for municipal, industrial and fishery use. The project's Stampede Powerplant has a maximum capacity of 4 MW.

250

Low Power BIST Based on Scan Partitioning Jinkyu Lee and Nur A. Touba  

E-Print Network (OSTI)

, touba}@ece.utexas.edu Abstract A built-in self-test (BIST) scheme is presented which both reduces while also significantly reducing the power dissipation. Weighted pattern testing has been well studied reduce hardware overhead for weighted random test and increase fault coverage compared

Touba, Nur A.

251

Exploiting Coarse-Grain Verification Parallelism for Power-Efficient Fault Tolerance  

E-Print Network (OSTI)

scaled, mi- croprocessors are becoming increasingly vulnerable to the impact of undesired energy exacerbate the already severe problem of power consumption and heat dissipation given a certain through- put that significantly reduces the energy overhead of replication without unduly impacting performance. Our approach

Albonesi, David H.

252

BEAM LINE  

NLE Websites -- All DOE Office Websites (Extended Search)

BEAM LINE BEAM LINE 45 W ILHELM ROENTGEN'S INITIAL DISCOVERY of X-radiation in 1895 led immediately to practical applications in medicine. Over the next few decades X rays proved to be an invaluable tool for the investigation of the micro-world of the atom and the development of the quantum theory of matter. Almost a century later, telescopes designed to detect X-radiation are indispensable for understanding the structure and evolution of the macro-world of stars, galaxies, and the Universe as a whole. The X-Ray Universe by WALLACE H. TUCKER X-ray images of the Universe are strikingly different from the usual visible-light images. 46 SUMMER 1995 did not think: I investigated." Undeterred by NASA's rejection of a proposal to search for cosmic X-radiation, Giacconi persuaded the

253

The Decline and Fall of Nuclear Power  

Science Journals Connector (OSTI)

The Decline and Fall of Nuclear Power ... As adults, as a nation, haven't we applied this same line of reasoning to our nuclear power industry? ...

LESLIE S. RAMSEY

1989-02-20T23:59:59.000Z

254

Designing AC Power Grids using Integer Linear Programming  

E-Print Network (OSTI)

A power grid is a transmission network transporting electrical energy from power ... cost factor for the active power losses, Re the line resistance, and Xe the...

2011-02-18T23:59:59.000Z

255

> REPLACE THIS LINE WITH YOUR PAPER IDENTIFICATION NUMBER (DOUBLE-CLICK HERE TO EDIT) < 1 Abstract--This paper presents techniques to reduce energy  

E-Print Network (OSTI)

energy, they also introduce errors that affect the performance quality. To compensate for these errors reduction and dynamic reduction for Discrete Cosine Transform shows, on average, 33% to 46% reduction overhead and achieve significant energy reduction with little quality degradation. Index Terms--low-power

Kambhampati, Subbarao

256

A distributed on-line HV transmission condition monitoring information system  

SciTech Connect

China Light and Power Company Ltd. (CLP) is responsible for supplying electricity to the whole of Hong Kong except Hong Kong Island and Lamma Island. In CLP`s Castle Peak power plant, 19 kV and 23 kV electric supplies are generated. The voltage is then stepped up to 400 kV for transmission. The intermediate control between those transformers and the major 400 kV overhead transmission system lies with a standard One and a half Breaker Configuration switch substations. The substation houses single phase encapsulated SF{sub 6} circuit breakers. In the urban centers, 400 kV substations are installed to step down 400 kV to 132 kV or further to 11 kV for distribution. This paper describes the development of a on-line distributed information system for monitoring the conditions of the whole HV transmission system. The system continuously monitors status of each circuit breaker (CB) together with important operational parameters, such as duration during making and breaking, operations of hydraulic pumps and SF{sub 6} gas pressure etc. Each group of CBs is monitored by a standalone microcontroller using a local area network with a baud rate of 9,600. The information can be recorded on the harddisk of an on-site microcomputer and further transmitted back to a remote computer for alarm generation and multi-station supervision. The CLP 400 kV substation and the Tsz Wan Shan 400 kV substation are among the first targets for development.

Chan, W.L. [Hong Kong Polytechnic Univ., Kowloon (Hong Kong)] [Hong Kong Polytechnic Univ., Kowloon (Hong Kong); Pang, S.L.; Chan, T.M. [China Light and Power Co. Ltd., Hong Kong (Hong Kong)] [China Light and Power Co. Ltd., Hong Kong (Hong Kong); So, A.T.P. [City Univ. of Hong Kong, Kowloon (Hong Kong)] [City Univ. of Hong Kong, Kowloon (Hong Kong)

1997-04-01T23:59:59.000Z

257

Reactive Power Compensator.  

DOE Patents (OSTI)

A system and method for determining and providing reactive power compensation for an inductive load. A reactive power compensator (50,50') monitors the voltage and current flowing through each of three distribution lines (52a, 52b, 52c), which are supplying three-phase power to one or more inductive loads. Using signals indicative of the current on each of these lines when the voltage waveform on the line crosses zero, the reactive power compensator determines a reactive power compensator capacitance that must be connected to the lines to maintain a desired VAR level, power factor, or line voltage. Alternatively, an operator can manually select a specific capacitance for connection to each line, or the capacitance can be selected based on a time schedule. The reactive power compensator produces control signals, which are coupled through optical fibers (102/106) to a switch driver (110, 110') to select specific compensation capacitors (112) for connections to each line. The switch driver develops triggering signals that are supplied to a plurality of series-connected solid state switches (350), which control charge current in one direction in respect to ground for each compensation capacitor. During each cycle, current flows from ground to charge the capacitors as the voltage on the line begins to go negative from its positive peak value. The triggering signals are applied to gate the solid state switches into a conducting state when the potential on the lines and on the capacitors reaches a negative peak value, thereby minimizing both the potential difference and across the charge current through the switches when they begin to conduct. Any harmonic distortion on the potential and current carried by the lines is filtered out from the current and potential signals used by the reactive power compensator so that it does not affect the determination of the required reactive compensation. 26 figs.

El-Sharkawi, M.A.; Venkata, S.S.; Chen, M.; Andexler, G.; Huang, T.

1992-07-28T23:59:59.000Z

258

Reactive power compensator  

DOE Patents (OSTI)

A system and method for determining and providing reactive power compensation for an inductive load. A reactive power compensator (50,50') monitors the voltage and current flowing through each of three distribution lines (52a, 52b, 52c), which are supplying three-phase power to one or more inductive loads. Using signals indicative of the current on each of these lines when the voltage waveform on the line crosses zero, the reactive power compensator determines a reactive power compensator capacitance that must be connected to the lines to maintain a desired VAR level, power factor, or line voltage. Alternatively, an operator can manually select a specific capacitance for connection to each line, or the capacitance can be selected based on a time schedule. The reactive power compensator produces control signals, which are coupled through optical fibers (102/106) to a switch driver (110, 110') to select specific compensation capacitors (112) for connections to each line. The switch driver develops triggering signals that are supplied to a plurality of series-connected solid state switches (350), which control charge current in one direction in respect to ground for each compensation capacitor. During each cycle, current flows from ground to charge the capacitors as the voltage on the line begins to go negative from its positive peak value. The triggering signals are applied to gate the solid state switches into a conducting state when the potential on the lines and on the capacitors reaches a negative peak value, thereby minimizing both the potential difference and across the charge current through the switches when they begin to conduct. Any harmonic distortion on the potential and current carried by the lines is filtered out from the current and potential signals used by the reactive power compensator so that it does not affect the determination of the required reactive compensation.

El-Sharkawi, Mohamed A. (Renton, WA); Venkata, Subrahmanyam S. (Woodinville, WA); Chen, Mingliang (Kirkland, WA); Andexler, George (Everett, WA); Huang, Tony (Seattle, WA)

1992-01-01T23:59:59.000Z

259

Adaptive Placement and Migration Policy for an STT-RAM-Based Hybrid Cache Daniel A. Jimnez  

E-Print Network (OSTI)

power of STT-RAM and low write overhead of SRAM. Such a hybrid cache design relies on an intelligent benefit from the high density and low leakage power of STT-RAM lines as well as the low write overhead portion of STT-RAM lines and a small portion of SRAM lines. Hybrid cache design depends on an intelli

Jiménez, Daniel A.

260

CADRE: Cycle-Accurate Deterministic Replay for Hardware DebuggingReplay for Hardware Debugging  

E-Print Network (OSTI)

OverheadPerformance Overhead Smruti R. Sarangi 4 #12;Design Bugs An example of a design bug in IBM G3 Power-Determinism Handling Non-Determinism in Busesg CADRE Architecture EvaluationEvaluation Space Overhead PerformanceAND L2 is being invalidated All the L2 lines might not be invalidated Two FeaturesTwo Features

Torrellas, Josep

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Connecticut ponders fuel cells for rail line  

Science Journals Connector (OSTI)

The Connecticut Department of Transportation is studying how fuel cell technology could be used to power trains and stations on Metro-North Railroad's New Haven Line. According to a report in The Stamford Advocate, the DOT wants to determine whether a fuel cell power station could replace some of the electric substations now used, taking the strain off Fairfield County's power grid.

2007-01-01T23:59:59.000Z

262

Auroral effects on power transmission line systems  

Science Journals Connector (OSTI)

... -south direction ( 166 km), is terminated at an autotransformer at the Gold Hill substation which is located just outside the city of Fairbanks. Aurora-induced current fluctuations in ... voltage developed across a 62.5 ?,O resistor inserted between the autotransformer neutral and substation ground.

S.-I. Akasofu; J. D. Aspnes

1982-01-14T23:59:59.000Z

263

On Line Power Plant Performance Monitoring  

E-Print Network (OSTI)

in achieving the best operation of the plant 3. To evaluate component performance and deterioration for use in a maintenance program 4. To develop cost data and incremental cost characteristics for the economic operation or dispatch of the unit... ? Analyze current plant?eQuipment status and diagnostics for preventive maintenance and equipment damage ? Provide current energy management and system dispatch operation information ? Capability for plant and equipment acceptance and periodic...

Ahner, D. J.; Priestley, R. R.

264

Thermal and air quality acceptability in buildings that reduce energy by reducing minimun airflow from overhead diffusers  

E-Print Network (OSTI)

controls system is an Automated Logic Controls system. Thisout that the existing Automated Logic U-line controllers diddatabase native to the Automated Logic control system and

2012-01-01T23:59:59.000Z

265

EIS-0486: Plains & Eastern Clean Line Transmission Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

86: Plains & Eastern Clean Line Transmission Project 86: Plains & Eastern Clean Line Transmission Project EIS-0486: Plains & Eastern Clean Line Transmission Project SUMMARY This EIS will evaluate the potential environmental impacts of participating with Clean Line Energy Partners LLC (Clean Line) in the proposed Plains & Eastern Project. The proposed project would include an overhead ± 600 kilovolt (kV) high voltage direct current (HVDC) electric transmission system and associated facilities with the capacity to deliver approximately 3,500 megawatts (MW) primarily from renewable energy generation facilities in the Oklahoma Panhandle region to load-serving entities in the Mid-South and Southeast via an interconnection with the Tennessee Valley Authority (TVA). PUBLIC COMMENT OPPORTUNITIES None available at this time.

266

Efficient Power System State Estimation  

E-Print Network (OSTI)

measure the data from the system components such as transmission line power flows, bus power injections monitoring of power systems. 2. Background Power systems have four main components: transmission, sub-transmission failure or generator outages. In the normal insecure state, a system may not be able to handle

Lavaei, Javad

267

Adaptive three-phase power-flow solutions for smart grids with plug-in hybrid electric vehicles  

Science Journals Connector (OSTI)

Abstract This paper introduces an adaptive three-phase power flow method for smart grids with plug-in hybrid electric vehicles (PHEVs). The proposed method is developed based on the loop frame of reference. The operations of smart grids are inherently unbalanced because of the incomplete three-phase feeder arrangements, nonsymmetrical conductor spacing of three-phase underground cables and overhead lines, unbalanced loads, and a variety of distributed energy resources (DERs). Therefore, the proposed method was developed based on the actual phase (abc) frame, rather than the sequence-component frame. To adapt the network topologies of smart grids, two solution strategies are used, one for radial smart grids and the other for non-radial smart grids. To demonstrate the validity and capability of the proposed algorithm, four IEEE feeder systems and an actual Taiwan Power Company (Taipower) distribution system are used as benchmarks for comparison purposes. The test results show that the proposed method is accurate, efficient, and adaptable, and it therefore has good potential for smart grid energy management system (EMS) applications.

Nien-Che Yang; Wei-Chih Tseng

2015-01-01T23:59:59.000Z

268

E-Print Network 3.0 - advanced intercross lines Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

intercross lines Search Powered by Explorit Topic List Advanced Search Sample search results for: advanced intercross lines Page: << < 1 2 3 4 5 > >> 1 Genet. Res., Camb. (1999),...

269

E-Print Network 3.0 - argon spectral lines Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

spectral lines Search Powered by Explorit Topic List Advanced Search Sample search results for: argon spectral lines Page: << < 1 2 3 4 5 > >> 1 Characterization of argon arc...

270

E-Print Network 3.0 - auroral emission lines Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

emission lines Search Powered by Explorit Topic List Advanced Search Sample search results for: auroral emission lines Page: << < 1 2 3 4 5 > >> 1 Annales Geophysicae, 23,...

271

E-Print Network 3.0 - avian lymphocyte lines Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

lymphocyte lines Search Powered by Explorit Topic List Advanced Search Sample search results for: avian lymphocyte lines Page: << < 1 2 3 4 5 > >> 1 Hematology and Immunology:...

272

Synthesis of Lumped Transmission-Line Analogs  

E-Print Network (OSTI)

Transmission lines and their lumped approximating networks have long been incorporated into radio-frequency power amplifiers to improve efficiency and shape circuit waveforms and are beginning to perform a similar roles ...

Phinney, Joshua W.

273

Data Collection for the Bonneville Power Administration Project on Wind Loading of Transmission Conductors  

Science Journals Connector (OSTI)

ABSTRACT The Bonneville Power Administration (BPA) project, Wind Effects on Conductors for Span Factors was established to determine the relationship between actual and theoretical wind loads on overhead transmission conductors. This study aims to improve BPA transmission line design methods and criteria as they relate to wind conditions in the Pacific Northwest. For the past seven years, BPA has collected data from seven sites in the Pacific Northwest. Measurements of wind speeds and directions, ambient temperatures and barometric pressures, and conductor swing angles enable engineers to compare measured wind loads on conductors to theoretical values. Impact of such variables as height of conductor, span lengths and conductor diameter are also investigated. Three sites were instrumented with vertically arranged anemometers to measure wind speed as a function of height above ground. This paper covers site determination, instrumentation, data collection, and some site maintenance and operation challenges. The maintenance and manipulation of the very large data base that has been collected is discussed. As data analysis is not yet finished, final results are not included.

H.W. VOLPE

1987-01-01T23:59:59.000Z

274

Secretary Chu Thanks Utility Staff and Line Workers For Their...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

facts? Utility companies have deployed 64,000 linemen and utility staff to the front lines to repair downed power lines and bring electricity back online. As they finish up in...

275

Power Plant Power Plant  

E-Print Network (OSTI)

Basin Center for Geothermal Energy at University of Nevada, Reno (UNR) 2 Nevada Geodetic LaboratoryStillwater Power Plant Wabuska Power Plant Casa Diablo Power Plant Glass Mountain Geothermal Area Lassen Geothermal Area Coso Hot Springs Power Plants Lake City Geothermal Area Thermo Geothermal Area

Tingley, Joseph V.

276

Power Factor Reactive Power  

E-Print Network (OSTI)

power: 130 watts Induction motor PSERC Incandescent lights 0 0.002 0.004 0.006 0.008 0.01 0.012 0.014 0 power: 150 watts #12;Page 4 PSERC Incandescent Lights PSERC Induction motor with no load #12;Page 5 Incandescent Lights #12;Page 7 PSERC Incandescent lights power: Power = 118 V x 1.3 A = 153 W = 0.15 kW = power

278

A TEM horn radiator for a nonlinear transmission line.  

E-Print Network (OSTI)

??A nonlinear transmission line (NLTL) provides a solid-state means of generating high power, microwave pulses. Although the design and construction of an NLTL is rather (more)

Simmons, Christopher

2014-01-01T23:59:59.000Z

279

second line of defense | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

second line of defense | National Nuclear Security Administration Facebook Twitter Youtube Flickr RSS People Mission Managing the Stockpile Preventing Proliferation Powering the...

280

Pulse power linac  

DOE Patents (OSTI)

A linear acceleration for charged particles is constructed of a plurality of transmission line sections that extend between a power injection region and an accelerating region. Each line section is constructed of spaced plate-like conductors and is coupled to an accelerating gap located at the accelerating region. Each gap is formed between a pair of apertured electrodes, with all of the electrode apertures being aligned along a particle accelerating path. The accelerating gaps are arranged in series, and at the injection region the line sections are connected in parallel. At the injection region a power pulse is applied simultaneously to all line sections. The line sections are graduated in length so that the pulse reaches the gaps in a coordinated sequence whereby pulse energy is applied to particles as they reach each of the gaps along the accelerating path.

Villa, Francesco (Alameda, CA)

1990-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Transmission Line Security Monitor: Final Report  

SciTech Connect

The Electric Power Transmission Line Security Monitor System Operational Test is a project funded by the Technical Support Working Group (TSWG). TSWG operates under the Combating Terrorism Technical Support Office that functions under the Department of Defense. The Transmission Line Security Monitor System is based on technology developed by Idaho National Laboratory. The technology provides a means for real-time monitoring of physical threats and/or damage to electrical transmission line towers and conductors as well as providing operational parameters to transmission line operators to optimize transmission line operation. The end use is for monitoring long stretches of transmission lines that deliver electrical power from remote generating stations to cities and industry. These transmission lines are generally located in remote transmission line corridors where security infrastructure may not exist. Security and operational sensors in the sensor platform on the conductors take power from the transmission line and relay security and operational information to operations personnel hundreds of miles away without relying on existing infrastructure. Initiated on May 25, 2007, this project resulted in pre-production units tested in realistic operational environments during 2010. A technology licensee, Lindsey Manufacturing of Azusa California, is assisting in design, testing, and ultimately production. The platform was originally designed for a security monitoring mission, but it has been enhanced to include important operational features desired by electrical utilities.

John Svoboda

2011-04-01T23:59:59.000Z

282

New Means of Transmitting Electricity: A Three-Way Race  

Science Journals Connector (OSTI)

...transmitting it-namely, an overhead power line-needs serious examination...studied as a possibility for power transmission in the future...trans-mission capacity). The Bonneville Power Administration has an 850-mile-long d-c...

William D. Metz

1972-12-01T23:59:59.000Z

283

Parallel Lines II: Construction of Parallel Lines  

Science Journals Connector (OSTI)

Situations are frequently encountered in which two lines, determined by linear regression, are theoretically...m 1 and m 2.

Ronald J. Tallarida Ph. D.; Rodney B. Murray Ph. D.

1987-01-01T23:59:59.000Z

284

Miter bend loss and higher order mode content measurements in overmoded millimeter-wave transmission lines  

E-Print Network (OSTI)

High power applications require an accurate calculation of the losses on overmoded corrugated cylindrical transmission lines. Previous assessments of power loss on these lines have not considered beam polarization or higher ...

Kowalski, Elizabeth J. (Elizabeth Joan)

2010-01-01T23:59:59.000Z

285

Line Extension Analysis | Open Energy Information  

Open Energy Info (EERE)

Line Extension Analysis Line Extension Analysis Jump to: navigation, search When a prospective electric customer requests service for a home or facility that is not currently serviced by the electric grid, the customer usually must pay a distance-based fee for the cost of extending power lines to the home or facility. In many cases, it is cheaper to use an on-site renewable energy system to meet a prospective customer’s electricity needs. Certain states require utilities to provide information regarding renewable energy options when prospective customers request a line extension. [1] Line Extension Analysis Incentives CSV (rows 1 - 12) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Authorization of Line Extension (Nebraska) Line Extension Analysis Nebraska Agricultural

286

Estes-Flatiron Transmission Line Rebuild  

NLE Websites -- All DOE Office Websites (Extended Search)

Estes-Flatiron Transmission Line Rebuild Estes-Flatiron Transmission Line Rebuild Skip Navigation Links Transmission Functions Infrastructure projects Interconnection OASIS OATT Estes-Flatiron Transmission Line Rebuild Project Western Area Power Administration proposes to rebuild approximately 32 miles of double wood-pole structure 115-kilovolt transmission line that exists between Estes Park and Flatiron Reservoir in Larimer County, Colo. The proposal would remove 16 miles of transmission line, and modernize 16 miles to steel-pole double-circuit 115-kV transmission line. The reduction and modernizing of transmission lines will occur on Federal, state and private lands. The public parcels are administered by the Arapaho and Roosevelt National Forest, which is a cooperating agency in the project.

287

Final joint environmental assessment for the construction and routine operation of a 12-kilovolt (KV) overhead powerline right-of-way, and formal authorization for a 10-inch and 8-inch fresh water pipeline right-of-way, Naval Petroleum Reserve No. 1, Kern County, California  

SciTech Connect

The purpose and need of the proposed action, which is the installation of an overhead powerline extension from an Naval Petroleum Reserve No. 1 (NPR-1) power source to the WKWD Station A, is to significantly reduce NPR-1`s overall utility costs. While the proposed action is independently justified on its own merits and is not tied to the proposed NPR-1 Cogeneration Facility, the proposed action would enable DOE to tie the NPR-1 fresh water pumps at Station A into the existing NPR-1 electrical distribution system. With the completion of the cogeneration facility in late 1994 or early 1995, the proposed action would save additional utility costs. This report deals with the environmental impacts of the construction of the powerline and the water pipeline. In addition, information is given about property rights and attaining permission to cross the property of proposed affected owners.

Not Available

1994-10-01T23:59:59.000Z

288

DOE/EA-1366; Environmental Assessment Santiam-Bethel Transmission Line Project (09/2001)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Preliminary Environmental Assessment Preliminary Environmental Assessment Santiam-Bethel Transmission Line Project Bonneville Power Administration September 2001 Santiam-Bethel Transmission Line Project Responsible Agency: U.S. Department of Energy, Bonneville Power Administration (BPA) Name of Proposed Project: Santiam-Bethel Transmission Line Project Abstract: Bonneville Power Administration proposes to rebuild the first 17 miles of the Santiam-Chemawa transmission line from Santiam Substation to the line's connection to Portland General Electric's Bethel Substation. BPA would replace the existing single-circuit 230-kilovolt (kV) line with towers that could support two circuits. The existing line supplies both Bethel Substation and BPA's Chemawa Substation. The new lines would eliminate

289

Microsoft PowerPoint - anderson_epri.ppt  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

control and power HIL experiments * Additional off-line simulation tools, i.e.: EMTDC, Matlab, PSSE * Established expertise in understanding the details of novel and legacy power...

290

Homeowners: Respond to Power Outages | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

work to restore power to critical infrastructure like power plants and transmission lines, water treatment facilities, and telecommunications networks, and also to hospitals,...

291

Indiana Michigan Power Co (Indiana) | Open Energy Information  

Open Energy Info (EERE)

Indiana) Indiana) Jump to: navigation, search Name Indiana Michigan Power Co Place Indiana Utility Id 9324 References EIA Form EIA-861 Final Data File for 2010 - File2_2010[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png COGEN/SPP - Cogeneration and/or Small Power Production Service CS-IRP2 - Contract Service Interruptible Power Industrial Cogeneration and/or Small Power Production - Standard Meter Industrial Cogeneration and/or Small Power Production - TOD Industrial ECLS - 100 watt HPS Lighting ECLS - 100 watt HPS - Overhead Circuitry Lighting ECLS - 100 watt HPS - Post-Top Lighting ECLS - 100 watt HPS - Underground Circuitry Lighting

292

Advance Funding and Development Agreement: Plains & Eastern Clean Line  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Advance Funding and Development Agreement: Plains & Eastern Clean Advance Funding and Development Agreement: Plains & Eastern Clean Line Transmission Project (September 20, 2012) Advance Funding and Development Agreement: Plains & Eastern Clean Line Transmission Project (September 20, 2012) Advance Funding and Development Agreement: Plains & Eastern Clean Line Transmission Project (September 20, 2012) More Documents & Publications Plains & Eastern Clean Line Project Proposal for New or Upgraded Transmission Line Projects Under Section 1222 of the Energy Policy Act of 2005 Letter from Deputy Secretary Poneman to Clean Line Energy Regarding the Plains & Eastern Clean Line Project Under Section 1222 of EPAct 2005 (April 5, 2012) 2013 Annual Planning Summary for the Southwestern Area Power Administration

293

Southwestern Power Administration  

NLE Websites -- All DOE Office Websites (Extended Search)

News Items News Items Skip Navigation Links December 7, 2012 Southwestern Helps Restore Power After Hurricane Sandy September 27, 2012 New Administrator April 27, 2012 Table Rock Visitor Center April 24, 2012 WFEC Earth Day Publications Skip Navigation Links Annual Performance Plan Annual Report Newsletters Press Releases Strategic Plan SWPA - Overview Video System Map December 7, 2012 Southwestern Helps Restore Power After Hurricane Sandy Southwestern Aids Sandy Recovery Line crews from Southwestern repair distribution lines in Tom's River, New Jersey, following Hurricane Sandy. In the aftermath of Hurricane Sandy in early November 2012, Southwestern Power Administration sent several line, substation, and right-of-way brush crews and 30 pieces of heavy equipment to help restore the electrical grid

294

Moving Toward Product Line Engineering in a Nuclear Industry Consortium  

E-Print Network (OSTI)

Moving Toward Product Line Engineering in a Nuclear Industry Consortium Sana Ben Nasr, Nicolas line engineering, variability mining 1. INTRODUCTION Nuclear power plants are some of the most.ben-nasr, nicolas.sannier, mathieu.acher, benoitbaudry}@inria.fr ABSTRACT Nuclear power plants are some of the most

Boyer, Edmond

295

Single transmission line data acquisition system  

DOE Patents (OSTI)

A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

Fasching, George E. (Morgantown, WV)

1984-01-01T23:59:59.000Z

296

Investigation of the sources of residential power frequency magnetic field exposure in the  

Science Journals Connector (OSTI)

There is an unexplained association between exposure to the magnetic fields arising from the supply and use of electricity, and increase in risk of childhood leukaemia. The UK Childhood Cancer Study (UKCCS) provides a large and unique source of information on residential magnetic field exposure in the UK. The purpose of this supplementary study was to investigate a sample of UKCCS homes in order to identify the particular sources that contribute to elevated time-averaged exposure. In all, 196 homes have been investigated, 102 with exposures estimated on the basis of the original study to be above 0.2??T, and 21 higher than 0.4??T, a threshold above which a raised risk has been observed. First, surveys were carried out outside the property boundaries of all 196 study homes, and then, where informed consent had been obtained, assessments were conducted inside the properties of 19 homes. The study found that low-voltage (LV) sources associated with the final electricity supply accounted together for 77% of exposures above 0.2??T, and 57% of those above 0.4??T. Most of these exposures were linked to net currents in circuits inside and/or around the home. High-voltage (HV) sources, including the HV overhead power lines that are the focus of public concern, accounted for 23% of the exposures above 0.2??T, and 43% of those above 0.4??T. Public health interest has focused on the consideration of precautionary measures that would reduce exposure to power frequency magnetic fields. Our study provides a basis for considering the options for exposure mitigation in the UK. For instance, in elevated-exposure homes where net currents are higher than usual, if it is possible to reduce the net currents, then the exposure could be reduced for a sizeable proportion of these homes. Further investigations would be necessary to determine whether this is feasible.

M P Maslanyj; T J Mee; D C Renew; J Simpson; P Ansell; S G Allen; E Roman

2007-01-01T23:59:59.000Z

297

Automated Surface Observing System: Standby Power Options  

Energy Savers (EERE)

for pilot briefing, air traffic control, & weather forecasters Public access dial phone lines Initially UPS designed to back 3 options under consideration to extend backup power to...

298

POWER GRID DYNAMICS: ENHANCING POWER SYSTEM OPERATION THROUGH PRONY ANALYSIS  

SciTech Connect

Prony Analysis is a technique used to decompose a signal into a series consisting of weighted complex exponentials and promises to be an effi cient way of recognizing sensitive lines during faults in power systems such as the U.S. Power grid. Positive Sequence Load Flow (PSLF) was used to simulate the performance of a simple two-area-four-generator system and the reaction of the system during a line fault. The Dynamic System Identifi cation (DSI) Toolbox was used to perform Prony analysis and use modal information to identify key transmission lines for power fl ow adjustment to improve system damping. The success of the application of Prony analysis methods to the data obtained from PSLF is reported, and the key transmission line for adjustment is identifi ed. Future work will focus on larger systems and improving the current algorithms to deal with networks such as large portions of the Western Electricity Coordinating Council (WECC) power grid.

Ray, C.; Huang, Z.

2007-01-01T23:59:59.000Z

299

DSW Power Projects  

NLE Websites -- All DOE Office Websites (Extended Search)

Power Projects Contact DSW Customers Customer Meetings Environmental Review-NEPA Operations & Maintenance Planning & Projects Power Marketing Power Projects Contact DSW Customers Customer Meetings Environmental Review-NEPA Operations & Maintenance Planning & Projects Power Marketing Rates DSW Power Projects Boulder Canyon: Straddling the Colorado River near the Arizona-Nevada border, Hoover Dam in Boulder Canyon creates Lake Mead. River waters turning turbines at Hoover Powerplant produce about 2,074 MW--enough electricity for nearly 8 million people. Western markets this power to public utilities in Arizona, California and Nevada over 53.30 circuit-miles of transmission line. Central Arizona: Authorized in 1968, the Central Arizona Project in Arizona and western New Mexico was built to improve water resources in the Colorado River Basin. Segments of the authorization allowed for Federal participation in the Navajo Generating Station. The Federal share of the powerplant's combined capacity is 547 MW.

300

North Australian Cloud Lines  

Science Journals Connector (OSTI)

A satellite classification and climatology of propagating mesoscale cloud fines in northern Australia is presented. These cloud fines range from long, narrow lines of shallow convection to extensive deep convective squall lines with mesoscale ...

W. Drosdowsky; G. J. Holland

1987-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Environmental Assessment and Finding of No Significant Impact: Western's Hoover Dam Bypass Project Phase II (Double-Circuiting a Portion of the Hoover-Mead No.5 and No.7 230-kV Transmission Lines with the Henderson-Mead No.1 230-kV Transmission Line, Clark County, Nevada)  

SciTech Connect

The U.S. Highway 93 (U.S. 93) Hoover Dam Bypass Project calls for the U.S. Department of Energy (DOE) Western Area Power Administration (Western) to remove its Arizona and Nevada (A&N) Switchyard. As a result of this action, Western must reconfigure its existing electrical transmission system in the Hoover Dam area. Western proposes to double-circuit a portion of the Hoover-Mead No.5 and No.7 230-kV Transmission Lines with the Henderson-Mead No.1 Transmission Line (see Figure 1-1). Double-circuiting is the placement of two separate electrical circuits, typically in the form of three separate conductors or bundles of conductors, on the same set of transmission line structures. The old Henderson-Hoover 230-kV Transmission Line would become the new Henderson-Mead No.1 and would extend approximately eight miles to connect with the Mead Substation. Western owns, operates, and maintains the Hoover-Mead No.5 and No.7, and Henderson-Hoover electrical power transmission lines. Additionally, approximately 0.25 miles of new right-of-way (ROW) would be needed for the Henderson-Mead No.1 when it transfers from double-circuiting with the Hoover-Mead No.7 to the Hoover-Mead No.5 at the Boulder City Tap. The proposed project would also involve a new transmission line ROW and structures where the Henderson-Mead No.1 will split from the Hoover-Mead No.5 and enter the northeast corner of the Mead Substation. Lastly, Western has proposed adding fiber optic overhead ground wire from the Hoover Power Plant to the Mead Substation on to the Henderson-Mead No.1, Hoover-Mead No.5 and No.7 Transmission Lines. The proposed project includes replacing existing transmission line tower structures, installing new structures, and adding new electrical conductors and fiber optic cables. As a consequence of these activities, ground disturbance may result from grading areas for structure placement, constructing new roads, improving existing roads for vehicle and equipment access, and from installing structures, conductors, and fiber optic cables. Project construction activities would be conducted within the existing 200-foot transmission line ROW and 50-foot access road ROW, although new spur access roads could occur outside of existing ROWs. As lead Federal agency for this action under National Environmental Policy Act (NEPA), Western must ensure that adverse environmental effects on Federal and non-Federal lands and resources are avoided or minimized. This Environmental Assessment (EA) is intended to be a concise public document that assesses the probable and known impacts to the environment from Western's Proposed Action and alternatives, and reaches a conclusion about the significance of the impacts. This EA was prepared in compliance with NEPA regulations published by the Council on Environmental Quality (40 CFR 1500-1508) and implementing procedures of the Department of Energy (10 CFR 1021).

N /A

2003-10-27T23:59:59.000Z

302

North American Power Symposium NAPS, San Luis Obispo, California, October 1999. EMTP Studies of UPFC Power Oscillation Damping  

E-Print Network (OSTI)

transmission sys- tems, rather then on building new transmission lines and power stations, for economical and reactive power on transmission lines to allow for their secure loading, to full thermal capability in some of power systems 3 . A 100 Mvar, 161 kV STATCOM prototype is already in service at TVA's power system 4

Cañizares, Claudio A.

303

Infrastructure systems, such as buildings, schools, roads, bridges, water lines, sewage systems, communication systems, and power plants, are a fundamental part of daily life. Both rapid and gradual climate changes can affect  

E-Print Network (OSTI)

and gradual climate changes can affect these systems and have significant impacts on society. Extreme weather infrastructure sector make practical decisions in order to adapt to climate changes and variations systems, communication systems, and power plants, are a fundamental part of daily life. Both rapid

304

Development of power facility management services using RFID/USN  

Science Journals Connector (OSTI)

In the electric power industry, there are many research projects to stabilise the power and increase the efficiency using ubiquitous technology. Many power utilities control and supervise the transmission line of energy to avoid power failures. In this ... Keywords: #, 47, RFID, RFID&, USN, cable joint, electric power industry, power facility management, radio frequency identification, service framework, ubiquitous sensor networks, wireless networks

Young-Il Kim; Jae-Ju Song; Jin-Ho Shin; Bong-Jae Yi; Hoon Choi

2009-03-01T23:59:59.000Z

305

Geothermal electric power plant status  

SciTech Connect

A status summary of the activity for the 44 proposed geothermal electric power plants in the United States as of March 31, 1981 is presented, as well as the power on-line electric plants to date. The information comes from the Department of Energy Geothermal Progress Monitor System (DOE, 1981).

Murphy, M.; Entingh, D.J.

1981-10-01T23:59:59.000Z

306

Authorization of Line Extension (Nebraska) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Authorization of Line Extension (Nebraska) Authorization of Line Extension (Nebraska) Authorization of Line Extension (Nebraska) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Nebraska Program Type Line Extension Analysis Provider Nebraska Public Power District Any entity permitted to establish an electric light and power plant, and/or

307

High power  

Science Journals Connector (OSTI)

... 1970s technomanic projects such as nuclear power stations were still in vogue. Environmentalists argued that solar power seemed a far safer, cheaper and reassuringly low-tech power source. The technomaniacs ... tech power source. The technomaniacs, fearing that they were losingthis argument, sought to hijack solar power themselves. They proposed an enormously expensive and complicated ...

David Jones

1994-03-03T23:59:59.000Z

308

Germ-line Allele  

NLE Websites -- All DOE Office Websites (Extended Search)

Germ-line Allele Germ-line Allele Name: Rachel Location: N/A Country: N/A Date: N/A Question: Can you please explain a "germ-line allele" to me! It is very important for a research paper I am writing about breast cancer. Replies: Mutations in genes are only able to be passed to the offspring if they are found in gametes (egg, sperm) mutations that occur in body cells other than gametes are usually not important because the cells can be replaced and they die eventually. The only way a characteristic can be passed to the offspring is through the eggs and sperm, so if there is a mutation in one these cells, the offspring can inherit the mutation. So a germ-line cell is a gamete. And a germ line allele is a version of the trait that is passed to the offspring through the germ line cell (or gamete).

309

Saguargo Solar Power Plant Solar Power Plant | Open Energy Information  

Open Energy Info (EERE)

Saguargo Solar Power Plant Solar Power Plant Saguargo Solar Power Plant Solar Power Plant Jump to: navigation, search Name Saguargo Solar Power Plant Solar Power Plant Facility Saguargo Solar Power Plant Sector Solar Facility Type Concentrating Solar Power Facility Status In Service Developer Solargenix Location Red Rock, Arizona Coordinates 32.54795°, -111.292887° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":32.54795,"lon":-111.292887,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

310

Flex power perspectives of indirect power system control through dynamic  

Open Energy Info (EERE)

Flex power perspectives of indirect power system control through dynamic Flex power perspectives of indirect power system control through dynamic power price (Smart Grid Project) Jump to: navigation, search Project Name Flex power perspectives of indirect power system control through dynamic power price Country Denmark Coordinates 56.26392°, 9.501785° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":56.26392,"lon":9.501785,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

311

Nematostatics of triple lines  

Science Journals Connector (OSTI)

The Landaude Gennes model for nematic liquid crystal bulk and interfaces has been extended to nematic triple lines involving the intersection of two isotropic fluids and one nematic liquid crystalline phase. A complete set of bulk, interface, and triple line force and torque balance equations has been formulated. The triple line force and torque balance equations have linear, interfacial, and bulk contributions. The bulk contributions appear as junction integrals, the surface contributions as junctions sums, and the line contributions as gradients of stresses. Reduction of dimensionality from three to one dimensional creates the following effects: (a) bulk terms enter interfacial balances as surface jumps and line balances as junction integrals, and (b) surface terms enter linear balances as junction sums. Line stress and torque equations are derived using classical liquid crystal models. The correspondence between line stress and line torque and their surface and bulk analogs is established. The triple line force and torque balance equations are use to analyze the contact angle in a nematic lens lying at the interface between two isotropic fluids, when the prefered surface orientation is tangential. The effect of anisotropy and long range elasticity on triple line phases is established. Under weak anchoring the contact angle is shown to be a function of the anchoring energy at the nematic-isotropic interface, while under strong anchoring conditions the contact angle is a function of the Peach-Koehler force that originates from bulk long range elasticity and acts on the triple line. The use of the complete set of balance equations removes the classical inconsistency in force balances at a contact line by properly taking into account long range (bulk gradient elasticity) and anisotropic (interfacial anchoring elasticity) effects.

Alejandro D. Rey

2003-01-30T23:59:59.000Z

312

Series Transmission Line Transformer  

DOE Patents (OSTI)

A series transmission line transformer is set forth which includes two or more of impedance matched sets of at least two transmissions lines such as shielded cables, connected in parallel at one end ans series at the other in a cascading fashion. The cables are wound about a magnetic core. The series transmission line transformer (STLT) which can provide for higher impedance ratios and bandwidths, which is scalable, and which is of simpler design and construction.

Buckles, Robert A. (Livermore, CA); Booth, Rex (Livermore, CA); Yen, Boris T. (El Cerrito, CA)

2004-06-29T23:59:59.000Z

313

Power Marketing  

NLE Websites -- All DOE Office Websites (Extended Search)

UGPS' Marketing Service Area Power Marketing As a marketer of Federal power in the Upper Great Plains Region, the Power Marketing staff provides a variety of services for customers...

314

Fiber optic sensors for monitoring sodium circuits and power grid cables  

SciTech Connect

At Kalpakkam, India, a programme on development of Raman Distributed Temperature sensor (RDTS) for Fast Breeder Reactors (FBR) application is undertaken. Leak detection in sodium circuits of FBR is critical for the safety and performance of the reactors. It is demonstrated that RDTS can be usefully employed in monitoring sodium circuits and in tracking the percolating sodium in case of any leak. Aluminum Conductor Steel Reinforced (ACSR) cable is commonly used as overhead power transmission cable in power grid. A second application demonstrates the suitability of using RDTS to monitor this transmission cable for any defect. (authors)

Kasinathan, M.; Sosamma, S.; Pandian, C.; Vijayakumar, V.; Chandramouli, S.; Nashine, B. K.; Rao, C. B.; Murali, N.; Rajan, K. K.; Jayakumar, T. [IGCAR, Kalpakkam (India)

2011-07-01T23:59:59.000Z

315

EA-1896: Williston to Stateline Transmission Line Project, Mountrail  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

96: Williston to Stateline Transmission Line Project, 96: Williston to Stateline Transmission Line Project, Mountrail Williams Electric Cooperative, Williston, North Dakota EA-1896: Williston to Stateline Transmission Line Project, Mountrail Williams Electric Cooperative, Williston, North Dakota Summary DOE's Western Area Power Administration is preparing this EA to evaluate the environmental impacts of interconnecting the proposed Stateline I transmission line, in Williston, North Dakota, to Western's transmission system. Public Comment Opportunities No public comment opportunities available at this time. Documents Available for Download May 4, 2012 EA-1896: Finding of No Significant Impact Williston to Stateline Transmission Line Project, Mountrail Williams Electric Cooperative, Williams County, North Dakota

316

Re-lining of scrubbers in flue gas desulfurization plants  

SciTech Connect

Rubber lining is used as corrosion protection material in scrubbers, tanks, pipe systems etc of European flue gas desulfurization plants. Although these rubber linings show in cases more than 15 years life, re-rubber lining is still necessary. Due to the expected higher availability of the power station units the time scale of such replacement must be kept to a minimum. As an efficient method for removal of the old lining the high pressure water systems has proven successful. Based on one such case of re-lining the working steps and time scale are demonstrated.

Fenner, J. [Keramchemie GmbH, Siershahn (Germany)

1999-11-01T23:59:59.000Z

317

Corona losses in HVdc bipolar lines  

SciTech Connect

The problem related to the prediction of corona losses in HVdc bipolar lines has been solved, in the past, by means of semi-empirical monomial formulae. However, the proposed formulae that are simpler to use do not always give adequate calculation precision, while the formulae that provide the closest results require implicit functions of different complexity, which are difficult to apply; moreover, it is not possible to understand clearly what influence the variations of the different line parameters have on the losses themselves. The new monomial semi-empirical relationship, proposed to predict the corona losses in HVdc bipolar lines, is very simple to use; it highlights the dependence of power losses due to the corona effect by the different line parameters. The formula has been developed by elaborating a considerable amount of available experimental data.

Corbellini, U.; Pelacchi, P. [Univ. of Pisa (Italy). Dept. of Electric Systems and Automation] [Univ. of Pisa (Italy). Dept. of Electric Systems and Automation

1996-07-01T23:59:59.000Z

318

EA-1891: Alvey-Fairview Transmission Line Rebuild Project, Oregon  

Energy.gov (U.S. Department of Energy (DOE))

This EA evaluates the environmental impacts of a proposal to rebuild DOEs Bonneville Power Administrations Alvey-Fairview No. 1 230-kV transmission line located between Eugene, Oregon, and Coquille, Oregon.

319

EIS-0106: Great Falls-Conrad Transmission Line Project, Montana  

Energy.gov (U.S. Department of Energy (DOE))

The Western Area Power Administration prepared this EIS to evaluate the environmental impacts of the construction and operation of a 230-kilovolt transmission line from Great Falls, Montana, to Conrad, Montana.

320

Use of refractory coatings on linings of electric resistance furnaces  

Science Journals Connector (OSTI)

Results of experimental and theoretical studies of the reduction of power consumption in furnaces with a lining covered by IVAKS-2 and IVA-2 intensifying refractory coatings are presented. The heating curves o...

A. V. Aksenov; V. A. Belyakov

1997-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Geodesic Lines, . . . Covariant . . .  

E-Print Network (OSTI)

Geodesic Lines, . . . Covariant . . . Home Page Title Page Page 781 of 818 Go Back Full Screen Close Quit 14.11. Geodesic Lines, Local Gauss-Bonnet Theorem Geodesics play a very important role in surface theory and in dynamics. One of the main reasons why geodesics are so important

Gallier, Jean

322

Transmission Line Security Monitor  

SciTech Connect

The Transmission Line Security Monitor is a multi-sensor monitor that mounts directly on high-voltage transmission lines to detect, characterize and communicate terrorist activity, human tampering and threatening conditions around support towers. For more information about INL's critical infrastructure protection research, visit http://www.facebook.com/idahonationallaboratory.

None

2011-01-01T23:59:59.000Z

323

Transmission Line Security Monitor  

ScienceCinema (OSTI)

The Transmission Line Security Monitor is a multi-sensor monitor that mounts directly on high-voltage transmission lines to detect, characterize and communicate terrorist activity, human tampering and threatening conditions around support towers. For more information about INL's critical infrastructure protection research, visit http://www.facebook.com/idahonationallaboratory.

None

2013-05-28T23:59:59.000Z

324

Two Line Subject Title One Line Title  

NLE Websites -- All DOE Office Websites (Extended Search)

- - Regional University Alliance (NETL-RUA) Grid Technologies Collaborative (GTC) Gregory Reed, PhD - University of Pittsburgh - GTC Lead (Director, Electric Power Initiative; Associate Director, Center for Energy; and Assoc. Professor, ECE Dept. - Swanson School of Engineering, PITT) * The Grid Technologies Collaborative (GTC) is an integrated industry-university-government research and development group that advances the state-of-the-art in transmission and distribution system level power electronics technologies. * Participants in the collaborative include industry partners and researchers from the U.S. Dept. of Energy's National Energy Technology Laboratory Regional University Alliance (NETL-

325

PowerPoint Presentation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

FACTS Control for Long- and Short- FACTS Control for Long- and Short- Term Energy Storage Mehdi Ferdowsi Missouri University of Science and Technology Funded by the Energy Storage Systems Program of the U.S. Department Of Energy (DOE/ESS) through Sandia National Laboratories (SNL). Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration, under contract DE-AC04-94AL85000. Issues * Short- and Long-Term Energy Storage * Storage Integration * Cyber Security 33 v v Transmission Line Generation FACTS Wind Power Energy Storage Solar Power Energy Storage FACTS Device Distributed Decisions Power Electronics Communications Sensing and monitoring Inputs Power Electronics

326

E-Print Network 3.0 - auroral field lines Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

field lines Search Powered by Explorit Topic List Advanced Search Sample search results for: auroral field lines Page: << < 1 2 3 4 5 > >> 1 Annales Geophysicae, 23, 15231531, 2005...

327

E-Print Network 3.0 - atomic absorption lines Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

lines Search Powered by Explorit Topic List Advanced Search Sample search results for: atomic absorption lines Page: << < 1 2 3 4 5 > >> 1 An output coupler for Bose condensed...

328

E-Print Network 3.0 - atomic carbon lines Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

lines Search Powered by Explorit Topic List Advanced Search Sample search results for: atomic carbon lines Page: << < 1 2 3 4 5 > >> 1 Gas Phase Reaction with FT-ICR and Molecular...

329

E-Print Network 3.0 - accelerator dump lines Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

dump lines Search Powered by Explorit Topic List Advanced Search Sample search results for: accelerator dump lines Page: << < 1 2 3 4 5 > >> 1 2005 ALCPG & ILC Workshops -Snowmass,...

330

E-Print Network 3.0 - atomic lines isotope Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

lines isotope Search Powered by Explorit Topic List Advanced Search Sample search results for: atomic lines isotope Page: << < 1 2 3 4 5 > >> 1 Isotope selectivity in laser cooling...

331

E-Print Network 3.0 - anomalously strong lines Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

lines Search Powered by Explorit Topic List Advanced Search Sample search results for: anomalously strong lines Page: << < 1 2 3 4 5 > >> 1 2942 VOLUME 58J O U R N A L O F T H E A...

332

PSO (FU 2101) Ensemble-forecasts for wind power  

E-Print Network (OSTI)

PSO (FU 2101) Ensemble-forecasts for wind power Analysis of the Results of an On-line Wind Power Ensemble- forecasts for wind power (FU2101) a demo-application producing quantile forecasts of wind power correct) quantile forecasts of the wind power production are generated by the application. However

333

Signature analysis of the primary components of the Koeberg nuclear power station / J.A. Bezuidenhout.  

E-Print Network (OSTI)

??In line with its commitment to safe nuclear power generation, the Koeberg Nuclear Power Station (KNPS) replaced the outdated vibration monitoring system with a modern (more)

Bezuidenhout, Jandr Albert

2010-01-01T23:59:59.000Z

334

Western Area Power Administration  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

v*Zy- i , . v*Zy- i , . r ,v * -i S # Af [, (e- . - o -A tl }r- 0 v-" l^~4~S J l ^-)^ I^U^ck iM clti ^ Power Administration Follow-up to Nov. 25, 2008 Transition Meeting Undeveloped Transmission Right-of-Way Western has very little undeveloped transmission right-of-way. There is a 7-mile right- of-way between Folsom, CA and Roseville, CA where Western acquired a 250' wide right-of-way but is only using half of it. Another line could be built parallel to Western's line to relieve congestion in the Sacramento area. In addition, Western has rights-of- way for many transmission lines that could be rebuilt to increase transmission capacity. For example, Western's Tracy-Livermore 230-kV line is a single circuit line but the existing towers could support a double circuit line. These rights-of-way would have to

335

Water Power Development in Canada and Malaya  

Science Journals Connector (OSTI)

... engineering skill in the Far East. The photographs shown of 66-kilovolt overhead wires and substations are very similar to corresponding systems in Europe.

1929-12-14T23:59:59.000Z

336

Z-Pinch Inertial Fusion Energy Fusion Power Associates Annual  

E-Print Network (OSTI)

@sandia.gov) LTD Cavity Recyclable Transmission Line Hohlraum #12;2 Outline · Refurbished Z · Pulsed power fusion 82 kV #12;7 Outline · Refurbished Z · Pulsed power fusion · Advances in pulsed power technology · Z Ray Lemke Strip-line geometry: S ~ Strip Width + AK "equivalent" AK gap d(t) from 1-D simulatio

337

EIS-0101: Thermopolis, Alcova, Casper Transmission Line Project  

Energy.gov (U.S. Department of Energy (DOE))

The Western Area Power Administration developed this statement to evaluate the environmental impacts of constructing, operating and maintaining a 230-kilovolt transmission line between Thermopolis, Wyoming, and Alcova, Wyoming, and a 230/345-kilovolt transmission line between Alcova, Wyoming, and Casper, Wyoming.

338

Delmarva Power Light Company Delmarva Power | Open Energy Information  

Open Energy Info (EERE)

Power Light Company Delmarva Power Power Light Company Delmarva Power Jump to: navigation, search Name Delmarva Power & Light Company (Delmarva Power) Place Wilmington, Delaware Zip 19886 Product Delmarva Power, a subsidiary of Pepco Holdings, is an electricity and natural gas provider. Coordinates 42.866922°, -72.868494° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.866922,"lon":-72.868494,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

339

New Jersey Solar Power LLC NJ Solar Power | Open Energy Information  

Open Energy Info (EERE)

Solar Power LLC NJ Solar Power Solar Power LLC NJ Solar Power Jump to: navigation, search Name New Jersey Solar Power LLC (NJ Solar Power) Place New Jersey Sector Solar Product A photovoltaic engineering firm which offers and installs a complete line of solar electric products for residential, commercial, and institutional customers. References New Jersey Solar Power LLC (NJ Solar Power)[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. New Jersey Solar Power LLC (NJ Solar Power) is a company located in New Jersey . References ↑ "New Jersey Solar Power LLC (NJ Solar Power)" Retrieved from "http://en.openei.org/w/index.php?title=New_Jersey_Solar_Power_LLC_NJ_Solar_Power&oldid=349171

340

Microsoft Word - Deering Lake-Eckley 115-kV Transmission Line...  

NLE Websites -- All DOE Office Websites (Extended Search)

Deering Lake-Eckley 115-kV Transmission Line Structure Replacements Yuma County, Colorado 1 A. Brief Description of Proposal: Western Area Power Administration (Western) proposes...

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Holes in Spectral Lines  

E-Print Network (OSTI)

The decay of an atom in the presence of a static perturbation is investigated. The perturbation couples a decaying state with a nondecaying state. A "hole" appears in the emission line at a frequency equal to the frequency ...

Fontana, Peter R.; Srivastava, Rajendra P.

1973-06-01T23:59:59.000Z

342

Electric Transmission Lines (Iowa)  

Energy.gov (U.S. Department of Energy (DOE))

Electric transmission lines capable of operating at 69 kV or greater cannot be constructed along, across, or over any public highways or grounds outside of cities without a franchise from the...

343

Lifting by Convergence Lines  

Science Journals Connector (OSTI)

The lifting depth of a convergence line in an unstratified boundary layer beneath a stably stratified atmosphere is examined with both analytical and numerical models. Cases are considered with and without flow in the layer above the convergence ...

N. Andrew Crook; Joseph B. Klemp

2000-03-01T23:59:59.000Z

344

DC powerline communication system using a transmission line transformer for high degree of freedom applications  

E-Print Network (OSTI)

A new type of powerline communication is developed to reduce cable requirements for robotic, electromechanical, and vehicular systems. A DC power bus line connecting a DC power supply to motor drives and sensor units is ...

Wade, Eric R. (Eric Randolph), 1978-

2004-01-01T23:59:59.000Z

345

Snow accretion on overhead wires  

Science Journals Connector (OSTI)

...the accreted snow and solar radiation, but these...Since the Japanese utilities experienced severe damage...positive air temperature, solar radiation or rain after...carried by the wire, solar radiation, temperature...France, CRIEPI and the utilities of Japan that have participated...

2000-01-01T23:59:59.000Z

346

Type B Accident Investigation Board Report on the July 25, 1997, Contract Brush Cutter Injury on the Ashe-Marion #2 500 kV Line  

Energy.gov (U.S. Department of Energy (DOE))

On July 25, 1997, at 1205 hours, a contract hand brush cutter was seriously injured when he felled a tree close to a Bonneville Power Administration energized transmission power line, located within a BPA transmission-line corridor.

347

1 INTRODUCTION We consider network protection (NP) by line switch-  

E-Print Network (OSTI)

framework applied to a realistic case study, i.e. the Italian 380kV power transmission grid, are summa as a network of N nodes (substations or buses) and K edges (transmission lines). Two types of buses that minimizes the consequences of cascading failures on an electrical grid. The 380 kV Italian power

Paris-Sud XI, Université de

348

Line tension vector thermodynamics of anisotropic contact lines  

Science Journals Connector (OSTI)

Multiphase materials with intersecting diving surfaces give rise to contact lines. A line tension vector thermodynamics formalism is developed and used to analyze contact line problems in the presence of anisotropy, taking into account two elastic modes: change in contact line length and change in contact line orientation. Using this formalism, the contact line-shape equation is derived, and the renormalization of the line tension due to anisotropy is characterized. The correspondence and analogies between the shape equation for anisotropic surfaces (Herring equation) and the shape equation for contact lines is established. Line energies for nematic liquid crystals, representative of generic anisotropic contact lines, are used to derive a shape equation that takes into account ambient orientation effects. It is found that anisotropic line tension may promote bending and chiral modes to avoid unfavorable orientations of the contact line with respect to the ambient nematic ordering.

Alejandro D. Rey

2004-04-30T23:59:59.000Z

349

Transmission planning for Indian power grid: a mixed integer programming approachp  

E-Print Network (OSTI)

) time-block (peak, intermediate, base) l index for transmission line voltage level (400, 220 and 132 kV transmission line, Rs/km LCAP power carrying capacity of an inter-state tie line for a particular voltage class, MW LF transmission loss factor per unit power transfer per km line length, MWh/MWh- km LGTH length

Dragoti-?ela, Eranda

350

Transformer modeling in power systems  

SciTech Connect

A practical and accurate method of modeling various transformers in power systems using a general circuit model approach is described in this paper. The advantage of the new approach is that it can model transformers along with a complex circuit network, while avoiding the use of symmetrical components, unlike other approaches. The transformer modeling technique introduced in this paper is very useful to accurately determine fault current distribution in a power system and electromagnetic interference on pipelines and communication lines installed in a right-of-way consisting of transmission lines operating at different voltages.

Ma, J.; Dawalibi, F.P. [Safe Engineering Services and Technologies Ltd., Montreal, Quebec (Canada)

1999-11-01T23:59:59.000Z

351

New Construction of Distribution Lines, Service Lines, and Appurtenant  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New Construction of Distribution Lines, Service Lines, and New Construction of Distribution Lines, Service Lines, and Appurtenant Facilities in Certain Visually Significant Resources Outside Residential Subdivisions (New York) New Construction of Distribution Lines, Service Lines, and Appurtenant Facilities in Certain Visually Significant Resources Outside Residential Subdivisions (New York) < Back Eligibility Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State New York Program Type Environmental Regulations Provider New York State Public Service Commission Any proposed construction of distribution lines, service lines, and appurtenant facilities to electric utilities located near scenic areas of

352

Definition: Line Transformer Monitors | Open Energy Information  

Open Energy Info (EERE)

Transformer Monitors Transformer Monitors Jump to: navigation, search Dictionary.png Line Transformer Monitors Transformer Monitoring System can monitor different aspects of transformers, including oil levels and multiple temperatures within the transformer. This allows for analysis of the health of either individual key power transformers or multiple power transformers networked in the system. For example, the transformer monitors provide transformer oil dissolved gas analysis (DGA), oil temperature, ambient temperature, and moisture in oil measurements. These measurements are made in relation to transformer load.[1] Related Terms transformer, system, transformer References ↑ https://www.smartgrid.gov/category/technology/line_transformer_monitors [[Cat LikeLike UnlikeLike You like this.Sign Up to see what your friends like.

353

Concentrating Solar Power  

Science Journals Connector (OSTI)

Concentrating Solar Power (CSP) has the potential to contribute significantly to the generation of electricity by renewable energy resources in the U.S.. Thermal storage can extend the duty cycle of CSP beyond daytime hours to early evening where the value of electricity is often the highest. The potential solar resource for the southwest U.S. is identified along with the need to add power lines to bring the power to consumers. CSP plants in the U.S. and abroad are described. The CSP cost of electricity at the busbar is discussed. With current incentives CSP is approaching competiveness with conventional gas?fired systems during peak?demand hours when the price of electricity is the highest. It is projected that a mature CSP industry of over 4 GWe will be able to reduce the energy cost by about 50% and that U.S. capacity could be 120 GW by 2050.

Mark Mehos

2008-01-01T23:59:59.000Z

354

An Introduction to Electric Power Transmission | Open Energy...  

Open Energy Info (EERE)

An Introduction to Electric Power Transmission Abstract An introduction to transmission lines including topics: electricity generation and delivery, ownership and funding, anatomy...

355

How a Geothermal Power Plant Works (Simple) - Text Version |...  

Energy Savers (EERE)

Lines Deliver Electricity Electrical current from the generator is sent to a step-up transformer outside the power plant. Voltage is increased in the transformer and electrical...

356

Electricity for road transport, flexible power systems and wind power  

Open Energy Info (EERE)

road transport, flexible power systems and wind power road transport, flexible power systems and wind power (Smart Grid Project) Jump to: navigation, search Project Name Electricity for road transport, flexible power systems and wind power Country Denmark Coordinates 56.26392°, 9.501785° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":56.26392,"lon":9.501785,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

357

Alluvial Gold Dredging in the Gold Coast Colony  

Science Journals Connector (OSTI)

... which the gold is recovered. The dredges are electrically operated and are supplied from individual substations fed by a 55 kv. overhead transmission line from the power station of Ankobra ...

1940-06-08T23:59:59.000Z

358

CX-012232: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Swan Valley-Teton Overhead Fiber Line Install CX(s) Applied: B4.6 Date: 06/02/2014 Location(s): Idaho Offices(s): Bonneville Power Administration

359

Apparent ridges for line drawing  

E-Print Network (OSTI)

Non-photorealistic line drawing depicts 3D shapes through the rendering of feature lines. A number of characterizations of relevant lines have been proposed but none of these definitions alone seem to capture all ...

Judd, Tilke (Tilke M.)

2007-01-01T23:59:59.000Z

360

Nuclear Powers Benefits  

Science Journals Connector (OSTI)

Nuclear Powers Benefits ... Using nuclear power in place of fossil-fuel energy sources, such as coal, has prevented some 1.8 million air-pollution-related deaths and 64 gigatons of carbon emissions globally over the past four decades, a study concludes. ... These estimates suggest policymakers should continue to rely on and expand nuclear power in place of fossil fuels to mitigate climate change, the authors say (Environ. ...

MARK SCHROPE

2013-04-08T23:59:59.000Z

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS--II: EXPRESS BRIEFS, VOL. 55, NO. 9, SEPTEMBER 2008 927 Using Transmission Line Outage Data to  

E-Print Network (OSTI)

Using Transmission Line Outage Data to Estimate Cascading Failure Propagation in an Electric Power transmission line outages recorded over nine years in an electric power system with approx- imately 200 lines. The average amount of propagation of the line outages is estimated from the data. The distribution

Dobson, Ian

362

Xtreme Power | Open Energy Information  

Open Energy Info (EERE)

Power Power Jump to: navigation, search Name Xtreme Power Place Kyle, Texas Zip 78640 Product Xtreme Power designs and manufactures power systems using power electronics and efficient storage technologies. Coordinates 29.98837°, -97.877369° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":29.98837,"lon":-97.877369,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

363

Harry: Between the Lines  

E-Print Network (OSTI)

I 5. ; ..v^-rr>.>-'- j??!*f fefi ( -??;r' ,, ;rl&.i:-??t**rK&d t ? -?, .- 'c-y. ~ :'y$???M .'??. ??.v-'-/i / ' , *? I te / - 5- MAGNUM FORCE: HARRY Between The Lines by Ruth Kurz Seeing Harry, instead of The Callahan... Image. (1973) Special thanks to Teri White for the original "first time"*scene. Further thanks JL MW AW DMc A production of AD NAUSEUM PRESS 3613 West Park Road Cleveland, Ohio 44111 MAGNUM FORCE: HARRY Between The Lines by ruth kurz ' "I...

Kurz, R.; White, T.

1982-01-01T23:59:59.000Z

364

A new time-frequency approach for hybrid differential and impedance protection of transmission lines  

Science Journals Connector (OSTI)

A new current differential protection of transmission lines is presented in this paper using an S-transform variant having very fast computational speed suitable for real-time applications. The conventional S-transform used earlier for transmission line protection has large computational overhead and thus is not suitable for generating decisions regarding the occurrence of a fault and its type on a transmission line. The new S-transform variant is based on different types of frequency scaling, band pass filtering, and interpolation techniques to achieve a significant reduction of computation time in comparison to the original S-transform. For wide area protection as in the case of smart grid the current differential protection is realised by extracting the relevant features from the current signals at both the sending end and receiving end terminals from the new S-transform generated contours. This paper focuses on the fault detection, classification, and location aspects using a new S-transform variant applied to synchronised measurement of the differential and average energy of current signals. Digital simulation results using EMTP for a long distance transmission line show the computational speed and efficiency of this new algorithm.

S.K. Swain; P.K. Dash

2014-01-01T23:59:59.000Z

365

Electric Power Generation and Transmission (Iowa)  

Energy.gov (U.S. Department of Energy (DOE))

Electric power generating facilities with a combined capacity greater than 25 MW, as well as associated transmission lines, may not be constructed or begin operation prior to the issuance of a...

366

Design of the ILC RTML Extraction Lines  

SciTech Connect

The ILC [1] Damping Ring to the Main Linac beamline (RTML) contains three extraction lines (EL). Each EL can be used both for an emergency abort dumping of the beam and tune-up continual train-by-train extraction. Two of the extraction lines are located downstream of the first and second stages of the RTML bunch compressor, and must accept both compressed and uncompressed beam with energy spreads of 2.5% and 0.15%, respectively. In this paper we report on an optics design that allowed minimizing the length of the extraction lines while offsetting the beam dumps from the main line by the distance required for acceptable radiation levels in the service tunnel. The proposed extraction lines can accommodate beams with different energy spreads while at the same time providing the beam size acceptable for the aluminum dump window. The RTML incorporates three extraction lines, which can be used for either an emergency beam abort or for a train-by-train extraction. The first EL is located downstream of the Damping Ring extraction arc. The other two extraction lines are located downstream of each stage of the two-stage bunch compressor. The first extraction line (EL1) receives 5GeV beam with an 0.15% energy spread. The extraction line located downstream of the first stage of bunch compressor (ELBC1) receives both compressed and uncompressed beam, and therefore must accept beam with both 5 and 4.88GeV energy, and 0.15% and 2.5% energy spread, respectively. The extraction line located after the second stage of the bunch compressor (ELBC2) receives 15GeV beam with either 0.15 or 1.8% energy spread. Each of the three extraction lines is equipped with the 220kW aluminum ball dump, which corresponds to the power of the continuously dumped beam with 5GeV energy, i.e., the beam trains must be delivered to the ELBC2 dump at reduced repetition rate.

Seletskiy, S.; Tenenbaum, P.; Walz, D.; /SLAC; Solyak, N.; /Fermilab

2011-10-17T23:59:59.000Z

367

Variable-Width Datapath for On-Chip Network Static Power Reduction  

SciTech Connect

With the tight power budgets in modern large-scale chips and the unpredictability of application traffic, on-chip network designers are faced with the dilemma of designing for worst- case bandwidth demands and incurring high static power overheads, or designing for an average traffic pattern and risk degrading performance. This paper proposes adaptive bandwidth networks (ABNs) which divide channels and switches into lanes such that the network provides just the bandwidth necessary in each hop. ABNs also activate input virtual channels (VCs) individually and take advantage of drowsy SRAM cells to eliminate false VC activations. In addition, ABNs readily apply to silicon defect tolerance with just the extra cost for detecting faults. For application traffic, ABNs reduce total power consumption by an average of 45percent with comparable performance compared to single-lane power-gated networks, and 33percent compared to multi-network designs.

Michelogiannakis, George; Shalf, John

2013-11-13T23:59:59.000Z

368

70 Home Power #64 April / May 1998 Code Corner  

E-Print Network (OSTI)

strikes. Utility- interactive inverters are subjected to surges on the power line. Systems using PV power-insulated conductor in power cords for ac-operated portable equipment is another example of an equipment grounding70 Home Power #64 · April / May 1998 Code Corner Grounding John Wiles Sponsored By The Photovoltaic

Johnson, Eric E.

369

Nuclear Power  

Science Journals Connector (OSTI)

Nuclear Power ... THIS WEEKS issue contains six letters on nuclear power, a representative sample of the letters C&EN received in response to the editorial, Resist Hysteria, I wrote shortly after the earthquake and tsunami in Japan devastated the Fukushima Daiichi Nuclear Power Station (C&EN, March 21, page 5). ... Four of the six letters take sharp issue with the primary point I made in the editorial, which was that, despite the severity of the situation in Japan, nuclear power remains an essential component of our overall energy mix for the near to mid-term because it will help us avert the worst impacts of global climate disruption. ...

RUDY M. BAUM

2011-05-09T23:59:59.000Z

370

Power LCAT  

SciTech Connect

POWER LCAT is a software tool used to compare elements of efficiency, cost, and environmental effects between different sources of energy.

Drennen, Thomas

2012-08-15T23:59:59.000Z

371

Yakama Power  

NLE Websites -- All DOE Office Websites (Extended Search)

Power Administration FROM: J.D. Williams Attorney RE: Initial Comments on Draft Load Following Regional Dialogue Contract Template Dear Mark, Please allow these comments...

372

Power LCAT  

ScienceCinema (OSTI)

POWER LCAT is a software tool used to compare elements of efficiency, cost, and environmental effects between different sources of energy.

Drennen, Thomas

2014-06-27T23:59:59.000Z

373

Kangley - Echo Lake Transmission Line Project, Final Environmental Impact Statement  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

STATEMENT STATEMENT Kangley-Echo Lake Transmission Line Project Final Environmental Impact Statement Responsible Agency: U.S. Department of Energy, Bonneville Power Administration (BPA) Cooperating Agency: U.S. Department of Agriculture, Forest Service (USFS) Title of Proposed Project: Kangley-Echo Lake Transmission Line Project State Involved: Washington Abstract: BPA is proposing to build a new transmission line to accommodate increasing demand for electricity and ensure reliability in the Puget Sound area. The Proposed Action would construct a new line that would connect to an existing transmis- sion line near the community of Kangley, and then connect with BPA's existing Echo Lake Substation. The major purpose of this proposal is to improve system reliability in the King County area. An outage on an existing line during times of heavy use, such as

374

EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project,  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3: Estes to Flatiron Substation Transmission Lines Rebuild 3: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO SUMMARY DOE's Western Area Power Administration (Western) owns and operates two 16-mile, 115-kilovolt transmission lines on separate rights-of-way between Flatiron Reservoir (near Loveland, Colorado) and the town of Estes Park, Colorado. Western is preparing this EIS to evaluate the environmental impacts of a proposal to upgrade and co-locate these transmission lines, by removing one and abandoning its right-of-way, and rebuilding the other along the existing right-of-way as a double-circuit line (i.e., six conductors per pole). The USDA Forest Service, Arapaho and Roosevelt National Forest, is a cooperating agency in preparing the EIS to support

375

EA-1960: Townsite Solar Project Transmission Line, Clark County, Nevada |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

60: Townsite Solar Project Transmission Line, Clark County, 60: Townsite Solar Project Transmission Line, Clark County, Nevada EA-1960: Townsite Solar Project Transmission Line, Clark County, Nevada SUMMARY The Bureau of Land Management, with Western Area Power Administration as a cooperating agency, prepared an EA to evaluate potential impacts of a proposal to build and operate a 180-MW photovoltaic facility; a 220, 230, or 500 kV transmission line; and associated facilities in Clark County, Nevada. PUBLIC COMMENT OPPORTUNITIES None available at this time. DOCUMENTS AVAILABLE FOR DOWNLOAD October 28, 2013 EA-1960: Finding of No Significant Impact Townsite Solar Project Transmission Line, Clark County, Nevada June 28, 2013 EA-1960: Final Environmental Assessment Townsite Solar Project Transmission Line, Clark County, Nevada

376

Printed circuit dispersive transmission line  

DOE Patents (OSTI)

A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other. 5 figures.

Ikezi, H.; Lin-Liu, Y.R.; DeGrassie, J.S.

1991-08-27T23:59:59.000Z

377

Printed circuit dispersive transmission line  

DOE Patents (OSTI)

A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other.

Ikezi, Hiroyuki (Rancho Santa Fe, CA); Lin-Liu, Yuh-Ren (San Diego, CA); DeGrassie, John S. (Encinitas, CA)

1991-01-01T23:59:59.000Z

378

After the Storm Immediately report downed power lines and  

E-Print Network (OSTI)

blizzards, heavy snows, or extreme cold, check to see that no physical damage has occurred and that water of overexertion and exhaustion. Shoveling snow in extreme cold causes many heart attacks. Set your priorities Weather Service winter weather advisories mean: Winter weather advisory ­ severe weather conditions exist

379

Power Business Line Decision Forums, as of March 14, 2005  

NLE Websites -- All DOE Office Websites (Extended Search)

Conservation Program Budget and Capital PFR PFR 4 5 Renewable Rate Credit Structure Renewables Workgroup, PFR, and Rate Case Structure - Renewables Workgroup Implementation - Rate...

380

Sierra Pacific Power Company Alturas Transmission Line Project...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

to mitigate significant visd impacts in Secret Valley along U.S. 395 and at the Tule Patch Spring Rest Stop. Alternative Segment ESVA: 23.0 es Proposed Segments L, N: 21.1...

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Multistability in nonlinear left-handed transmission lines David A. Powell,a  

E-Print Network (OSTI)

Multistability in nonlinear left-handed transmission lines David A. Powell,a Ilya V. Shadrivov; published online 2 July 2008 Employing a nonlinear left-handed transmission line as a model system, we, which at higher power may result in chaotic dynamics of the transmission line. © 2008 American Institute

382

Scha's Parallel Lines Bernhard Nickel  

E-Print Network (OSTI)

Scha's Parallel Lines Bernhard Nickel May 10, 2010 1 Introduction Scha (1981) has a famous example) The single lines run parallel to the double lines. 3 Code for Figure 1 \\begin{figure} \\centering \\setlength{\\unitlength}{.5in} \\begin{picture}(6,4) % first square \\put(0,4){\\line(1,0){4}}% \\put(0,1){\\line(1,0){4}}% \\put(0

Nickel, Bernhard

383

Drill string transmission line  

DOE Patents (OSTI)

A transmission line assembly for transmitting information along a downhole tool comprising a pin end, a box end, and a central bore traveling between the pin end and the box end, is disclosed in one embodiment of the invention as including a protective conduit. A transmission line is routed through the protective conduit. The protective conduit is routed through the central bore and the ends of the protective conduit are routed through channels formed in the pin end and box end of the downhole tool. The protective conduit is elastically forced into a spiral or other non-linear path along the interior surface of the central bore by compressing the protective conduit to a length within the downhole tool shorter than the protective conduit.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David S. (Lehi, UT); Bradford, Kline (Orem, UT); Fox, Joe (Spanish Fork, UT)

2006-03-28T23:59:59.000Z

384

Secretary Chu Thanks Utility Staff and Line Workers For Their Efforts to  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Thanks Utility Staff and Line Workers For Their Thanks Utility Staff and Line Workers For Their Efforts to Restore Power in the Wake of Hurricane Sandy Secretary Chu Thanks Utility Staff and Line Workers For Their Efforts to Restore Power in the Wake of Hurricane Sandy November 2, 2012 - 11:32am Addthis Secretary Chu meets with Pepco line workers in Maryland on November 1, 2012. | Photo by Sarah Gerrity Secretary Chu meets with Pepco line workers in Maryland on November 1, 2012. | Photo by Sarah Gerrity Jen Stutsman Press Secretary, Office of Public Affairs What are the key facts? Utility companies have deployed 64,000 linemen and utility staff to the front lines to repair downed power lines and bring electricity back online. As they finish up in one area, workers move on to continue assisting other areas still recovering from the storm.

385

Solar Power  

NLE Websites -- All DOE Office Websites (Extended Search)

Solar Power Solar Power Project Opportunities Abound in the Region The WIPP site is receives abundant solar energy with 6-7 kWh/sq meter power production potential As the accompanying map of New Mexico shows, the WIPP site enjoys abundant year-round sunshine. With an average solar power production potential of 6-7 kWh/sq meter per day, one exciting project being studied for location at WIPP is a 30-50 MW Solar Power Tower: The American Solar Energy Society (ASES) is is a national trade association promoting solar energy as a clean source of electricity, and provides a comprehensive resource for additional information. DOE's Office of Energy Efficiency and Renewable Energy is also a comprehensive resource for more information on renewable energy.

386

Power system  

DOE Patents (OSTI)

A power system includes a prime mover, a transmission, and a fluid coupler having a selectively engageable lockup clutch. The fluid coupler may be drivingly connected between the prime mover and the transmission. Additionally, the power system may include a motor/generator drivingly connected to at least one of the prime mover and the transmission. The power-system may also include power-system controls configured to execute a control method. The control method may include selecting one of a plurality of modes of operation of the power system. Additionally, the control method may include controlling the operating state of the lockup clutch dependent upon the mode of operation selected. The control method may also include controlling the operating state of the motor/generator dependent upon the mode of operation selected.

Hickam, Christopher Dale (Glasford, IL)

2008-03-18T23:59:59.000Z

387

New Construction of Distribution Lines, Service Lines, and Appurtenant  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Construction of Distribution Lines, Service Lines, and Construction of Distribution Lines, Service Lines, and Appurtenant Facilities in Residential Subdivisions (New York) New Construction of Distribution Lines, Service Lines, and Appurtenant Facilities in Residential Subdivisions (New York) < Back Eligibility Commercial Installer/Contractor Institutional Investor-Owned Utility Low-Income Residential Multi-Family Residential Municipal/Public Utility Residential Rural Electric Cooperative Schools Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Home Weatherization Water Buying & Making Electricity Solar Wind Program Info State New York Program Type Siting and Permitting Provider New York State Public Service Commission Any proposed construction of electricity-related facilities in residential

388

Perfect Power | Open Energy Information  

Open Energy Info (EERE)

Perfect Power Perfect Power Jump to: navigation, search Name Perfect Power Place Phoenix, Arizona Zip 85028 Sector Solar Product Perfect Power operates the worldâ€(tm)s largest solar power community, GreenWood Ranch Estates, 520 five-acre lots in Arizona. Coordinates 33.44826°, -112.075774° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":33.44826,"lon":-112.075774,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

389

Clean Coal Power Initiative  

SciTech Connect

This report is the fifth quarterly Technical Progress Report submitted by NeuCo, Incorporated, under Award Identification Number, DE-FC26-04NT41768. This award is part of the Clean Coal Power Initiative (''CCPI''), the ten-year, $2B initiative to demonstrate new clean coal technologies in the field. This report is one of the required reports listed in Attachment B Federal Assistance Reporting Checklist, part of the Cooperative Agreement. The report covers the award period January 1, 2006 - March 31, 2006 and NeuCo's efforts within design, development, and deployment of on-line optimization systems during that period.

Doug Bartlett; Rob James; John McDermott; Neel Parikh; Sanjay Patnaik; Camilla Podowski

2006-03-31T23:59:59.000Z

390

Optimized Jacobian Matrix Solution of a generalized electric power network  

E-Print Network (OSTI)

and transmission lines as well as power rcqui emcnts at specified points of the network. A , ample e' cctrical network i depicted in I'igure 1. The different types of nodal points are described in Appendix $. Electrical power companies use power flow analysis...'icient precision for analyzing power los, es on transmission lines. At this point, power industiy personnel began to look a, t the capabilities of auto- mat, ic d' gi tal computers for the solution oi' power system problems. Ir. Gctober of 1955, J. B. lard...

Moore, Jimmie Archer

2012-06-07T23:59:59.000Z

391

Biennial Assessment of the Fifth Power Plan Transmission Issues  

E-Print Network (OSTI)

by the partners in the Colstrip 500 kV transmission lines (Northwestern Energy, Puget Sound Energy, Portland unscheduled electricity flows over transmission lines leading to increased risks to electric systemBiennial Assessment of the Fifth Power Plan Transmission Issues INTRODUCTION The Fifth Power Plan

392

Power Systems Engineering Research Center PSERC Background Paper  

E-Print Network (OSTI)

the shortest route from the generator to the load. Instead, electric power flows through the transmission system based on the relative resistance to power flows of each transmission line across the system. For example, just like an extension cord from the local hardware store, each transmission line has a maximum

393

Strathclyde powerS ahead  

E-Print Network (OSTI)

Strathclyde powerS ahead the future of renewable energy SHARING AND ENHANCING RESEARCH Discover the vision of Principal Professor Jim McDonald THE FUTURE OF ENERGY Strathclyde pioneers renewableEdicinE Snapshot the reSearcher Following a decade of environmental research in her native egypt, nabila saleem

Mottram, Nigel

394

Design Enablement and Design-Centric Assessment of Future Semiconductor Technologies  

E-Print Network (OSTI)

line STDP compatible designs showing negligible area overhead. . . . . . . . . . . . . . . . . . . . . . .line STDP compatible designs showing negligible area overhead.design implementation of STDP at the poly-line layer is achieved with 1.8 pitch relaxation with virtually no area overhead;

Abou Ghaida, Rani

2012-01-01T23:59:59.000Z

395

Power America  

Energy.gov (U.S. Department of Energy (DOE))

Power America will focus on wide bandgap (WBG) semiconductors - the same materials used in LED light fixtures and many flat screen TVs. The Institute will use $70 million provided by the U.S. Department of Energy's Advanced Manufacturing Office to support and manage its programs over the next five years. This Institute is one of three new innovation hubs announced by President Obama in his 2013 State of the Union address and part of the National Network for Manufacturing Innovation (NNMI). Power America was formerly called the Next Generation Power Electronics National Manufacturing Innovation Institute.

396

Supply of geothermal power from hydrothermal sources: A study of the cost of power in 20 and 40 years  

SciTech Connect

This study develops estimates for the amount of hydrothermal geothermal power that could be on line in 20 and 40 years. This study was intended to represent a snapshot'' in 20 and 40 years of the hydrothermal energy available for electric power production should a market exist for this power. This does not represent the total or maximum amount of hydrothermal power, but is instead an attempt to estimate the rate at which power could be on line constrained by the exploration, development and support infrastructure available to the geothermal industry, but not constrained by the potential market for power.

Petty, S. (Petty (Susan) Consulting, Solano Beach, CA (United States)); Livesay, B.J. (Livesay Consultants, Inc., Encinitas, CA (United States)); Long, W.P. (Carlin Gold Co., Inc., Grass Valley, CA (United States)); Geyer, J. (Geyer (John) and Associates, Vancouver, WA (United States))

1992-11-01T23:59:59.000Z

397

Neural net application to transmission line fault detection and classification  

E-Print Network (OSTI)

NEURAL NET APPLICATION TO TRANSMISSION LINE FAULT DETECTION AND CLASSIFICATION A Thesis by IGOR RIKALO Submitted to Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE Approve as to style... Applicanon to Transmission Line Fault Detection and Classification. (December 1994) Igor Rikalo, B. S. University of Sarajevo Chair of Advisory Committee: Dr. Mladen Kezunovic Today, in electric power systems, a large amount of data is made readily...

Rikalo, Igor

2012-06-07T23:59:59.000Z

398

EIS-0507: Boardman-Hemingway Transmission Line, Oregon and Idaho  

Energy.gov (U.S. Department of Energy (DOE))

The Bureau of Land Management and the U.S. Forest Service are preparing, with DOEs Bonneville Power Administration (BPA) as a cooperating agency, an EIS that evaluates the potential environmental impacts of a proposal to construct about 305 miles of 500-kV transmission line from northeast Oregon to southwest Idaho. BPAs proposed action is to partially fund part the transmission line. Additional information is available at www.boardmantohemingway.com.

399

Categorical Exclusion Determinations: Southwestern Power Administration |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Southwestern Power Southwestern Power Administration Categorical Exclusion Determinations: Southwestern Power Administration Categorical Exclusion Determinations issued by Southwestern Power Administration. DOCUMENTS AVAILABLE FOR DOWNLOAD August 6, 2013 CX-010879: Categorical Exclusion Determination Transmission Line 3005, Structure 290 Replacement CX(s) Applied: B4.6 Date: 08/06/2013 Location(s): Oklahoma Offices(s): Southwestern Power Administration July 25, 2013 CX-010880: Categorical Exclusion Determination Transmission Line 3016, Access Road Acquisition Project CX(s) Applied: B1.24 Date: 07/25/2013 Location(s): Oklahoma Offices(s): Southwestern Power Administration July 22, 2013 CX-010716: Categorical Exclusion Determination Short Mountain Access Road Easement Acquisition CX(s) Applied: B1.24

400

Northern States Power Co - Minnesota (North Dakota) | Open Energy  

Open Energy Info (EERE)

3781 3781 References EIA Form EIA-861 Final Data File for 2010 - File2_2010[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png D01 Residential Overhead Standard Residential D02 Residential Time of Day Service Residential D12 Small General Service Commercial D14 Small General Time of Day Service Commercial D16 General service Commercial D17 General Time of Day Service Commercial Average Rates Residential: $0.0814/kWh Commercial: $0.0713/kWh Industrial: $0.0564/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File2_2010" Retrieved from "http://en.openei.org/w/index.php?title=Northern_States_Power_Co_-_Minnesota_(North_Dakota)&oldid=412731

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Northern States Power Co - Minnesota (North Dakota) | Open Energy  

Open Energy Info (EERE)

Energy North Dakota) Energy North Dakota) Jump to: navigation, search Name Northern States Power Co - Minnesota Place North Dakota Utility Id 13781 References EIA Form EIA-861 Final Data File for 2010 - File2_2010[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png D01 Residential Overhead Standard Residential D02 Residential Time of Day Service Residential D12 Small General Service Commercial D14 Small General Time of Day Service Commercial D16 General service Commercial D17 General Time of Day Service Commercial Average Rates Residential: $0.0814/kWh Commercial: $0.0713/kWh Industrial: $0.0564/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File2_2010"

402

Power Struggle  

Science Journals Connector (OSTI)

Disparate forces such as hydraulic fracturing, or fracking, in the U.S.; the phaseout of nuclear power in Germany; and renewable energy promotion in Europe are conspiring to lessen ... ...

ALEX SCOTT

2013-12-09T23:59:59.000Z

403

Prepping Power Engineers for the Smart Grid | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Prepping Power Engineers for the Smart Grid Prepping Power Engineers for the Smart Grid Prepping Power Engineers for the Smart Grid June 19, 2012 - 4:01pm Addthis This video examines electrostatic induction, a phenomenon that means a conductive object in the vicinity of a power line may have energy coupled to it even if it's not connected to the line. Check out the other videos created by the partnership Bonneville Power Administration, Washington State University and the Northwest Workforce Training Center for Electric Power Engineering on their Smart Grid YouTube playlist. Joel Scruggs Public Affairs Specialist, Bonneville Power Administration BPA's High Voltage Lab: Ever wonder why electricity makes power lines sag? This video explains why. Check out the Smart Grid Workforce playlist for other videos from

404

a 115-line MATLAB implementation  

E-Print Network (OSTI)

Apr 15, 2013 ... Alternating active-phase algorithm for multimaterial topology optimization problems -- a 115-line MATLAB implementation. Rouhollah Tavakoli...

Rouhollah Tavakoli

2013-04-15T23:59:59.000Z

405

Transmission Line Circuit Alexander Glasser  

E-Print Network (OSTI)

Chaos in a Transmission Line Circuit Alexander Glasser Marshal Miller With... Prof. Edward Ott Prof times become shorter, circuit connections behave more and more like transmission lines. Theoretical(t) - Transmission Line (Zo, T) #12;5 Cf/Cr 1000 Vf Capacitance Voltage Cf Cr Model for Nonlinear Capacitor

Anlage, Steven

406

CORONAL EMISSION LINES AS THERMOMETERS  

SciTech Connect

Coronal emission-line intensities are commonly used to measure electron temperatures using emission measure and/or line ratio methods. In the presence of systematic errors in atomic excitation calculations and data noise, the information on underlying temperature distributions is fundamentally limited. Increasing the number of emission lines used does not necessarily improve the ability to discriminate between different kinds of temperature distributions.

Judge, Philip G., E-mail: judge@ucar.ed [High Altitude Observatory, National Center for Atmospheric Research , P.O. Box 3000, Boulder CO 80307-3000 (United States)

2010-01-10T23:59:59.000Z

407

Why Neutrino Lines are Hypersharp  

E-Print Network (OSTI)

It was recently pointed out that mono-energetic neutrino lines from the 2-body decay of tritium (tau ~ 18-y) can be emitted, a significant fraction, with natural line width (~10-24 eV) for hypersharp resonance transitions 3H--> line broadening in resonances of short lived (tau ~ microsec) states.

R. S. Raghavan

2009-08-20T23:59:59.000Z

408

Coronal emission lines as thermometers  

E-Print Network (OSTI)

Coronal emission line intensities are commonly used to measure electron temperatures using emission measure and/or line ratio methods. In the presence of systematic errors in atomic excitation calculations and data noise, the information on underlying temperature distributions is fundamentally limited. Increasing the number of emission lines used does not necessarily improve the ability to discriminate between different kinds of temperature distributions.

Judge, Philip G

2009-01-01T23:59:59.000Z

409

NNSA's Second Line of Defense Program Receives Capability Award |  

NLE Websites -- All DOE Office Websites (Extended Search)

Second Line of Defense Program Receives Capability Award | Second Line of Defense Program Receives Capability Award | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > NNSA's Second Line of Defense Program Receives ... NNSA's Second Line of Defense Program Receives Capability Award Posted By Office of Public Affairs NNSA's Second Line of Defense (SLD) was awarded the 2013 Non-Conventional

410

Second Line of Defense Program | National Nuclear Security Administration  

NLE Websites -- All DOE Office Websites (Extended Search)

Line of Defense Program | National Nuclear Security Administration Line of Defense Program | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Second Line of Defense Program Home > About Us > Our Programs > Nonproliferation > International Materials Protection and Cooperation > Second Line of Defense Program Second Line of Defense Program In April 2009, President Obama called the danger of a terrorist acquiring

411

Second Line of Defense Program | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Line of Defense Program | National Nuclear Security Administration Line of Defense Program | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Second Line of Defense Program Home > About Us > Our Programs > Nonproliferation > International Materials Protection and Cooperation > Second Line of Defense Program Second Line of Defense Program In April 2009, President Obama called the danger of a terrorist acquiring

412

On-line Monitoring [Laser Applications Laboratory] - Nuclear Engineering  

NLE Websites -- All DOE Office Websites (Extended Search)

On-line Monitoring On-line Monitoring Capabilities Engineering Experimentation Reactor Safety Experimentation Aerosol Experiments System Components Laser Applications Overview Laser Oil & Gas Well Drilling Laser Heat Treatment Laser Welding of Metals On-line Monitoring Laser Beam Delivery Laser Glazing of Railroad Rails High Power Laser Beam Delivery Decontamination and Decommissioning Refractory Alloy Welding Robots Applications Other Facilities Other Capabilities Work with Argonne Contact us For Employees Site Map Help Join us on Facebook Follow us on Twitter NE on Flickr Laser Applications Laboratory On-line Monitoring Project description: On-line process monitoring for laser-beam welding. Category: Project with industrial partner (USCAR) Bookmark and Share Simulated defects and associated responses from a weld sensor developed at Argonne

413

A reactor core on-line monitoring program - COMP  

SciTech Connect

A program named COMP is developed for on-line monitoring PWRs' in-core power distribution in this paper. Harmonics expansion method is used in COMP. The Unit 1 reactor of Daya Bay Nuclear Power Plant (Daya Bay NPP) in China is considered for verification. The numerical results show that the maximum relative error between measurement and reconstruction results from COMP is less than 5%, and the computing time is short, indicating that COMP is capable for online monitoring PWRs. (authors)

Wang, C. [State Nuclear Power Software Development Center, Beijing, 100029 (China); School of Nuclear Science and Technology, Xi'an Jiaotong Univ. (China); Building 1, Compound No.29, North Third Ring Road, Xicheng District, Beijing, 100029 (China); Wu, H.; Cao, L. [School of Nuclear Science and Technology, Xi'an Jiaotong Univ. (China)

2012-07-01T23:59:59.000Z

414

TGI Solar Power Group | Open Energy Information  

Open Energy Info (EERE)

TGI Solar Power Group TGI Solar Power Group Jump to: navigation, search Name TGI Solar Power Group Place New York, New York Zip 10001 Sector Solar Product TGI Solar Power Group specialises in the manufacture and integration of thin film PV fabrication lines, PV thin film manufacturing equipment, as well as project development. References TGI Solar Power Group[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. TGI Solar Power Group is a company located in New York, New York . References ↑ "TGI Solar Power Group" Retrieved from "http://en.openei.org/w/index.php?title=TGI_Solar_Power_Group&oldid=352158" Categories: Clean Energy Organizations Companies Organizations

415

Prognostic Control and Load Survivability in Shipboard Power Systems  

E-Print Network (OSTI)

, etc. Transmission systems consist of transformers, circuit breakers, and transmission lines to deliver power from the generation power plants to distribution systems. Commercial, residential, and industrial customers are the types of loads served... cannot supply power to it, then it should be powered through its alternate path. The process of restoring, balancing, and minimizing power losses to loads is called network reconfiguration. Prognostics is the ability to predict precisely and accurately...

Thomas, Laurence J.

2011-02-22T23:59:59.000Z

416

Transmission line route selection by goal programming  

Science Journals Connector (OSTI)

A two-stage solution for transmission line route selection is presented. The generalized double-sweep method has been used to select the K least costly routes. The selected routes are subjected to social and environmental constraints (SEC). The SEC problem is formulated as a zero-one goal-programming model and solved by the implicit enumeration method. The two-stage solution algorithm has been applied to two problems. The results indicate the suitability of the method for route selection provided that acceptable SEC criteria can be found. The results also indicate the viability of the goal-programming technique for choosing power network interconnection concepts.

I.M. Elamin; S.O. Duffuaa; H.A. Yassein

1990-01-01T23:59:59.000Z

417

Power inverters  

DOE Patents (OSTI)

Power inverters include a frame and a power module. The frame has a sidewall including an opening and defining a fluid passageway. The power module is coupled to the frame over the opening and includes a substrate, die, and an encasement. The substrate includes a first side, a second side, a center, an outer periphery, and an outer edge, and the first side of the substrate comprises a first outer layer including a metal material. The die are positioned in the substrate center and are coupled to the substrate first side. The encasement is molded over the outer periphery on the substrate first side, the substrate second side, and the substrate outer edge and around the die. The encasement, coupled to the substrate, forms a seal with the metal material. The second side of the substrate is positioned to directly contact a fluid flowing through the fluid passageway.

Miller, David H. (Redondo Beach, CA); Korich, Mark D. (Chino Hills, CA); Smith, Gregory S. (Woodland Hills, CA)

2011-11-15T23:59:59.000Z

418

Bauer Power | Open Energy Information  

Open Energy Info (EERE)

Bauer Power Bauer Power Jump to: navigation, search Logo: Bauer Power Name Bauer Power Address 1657 12th Street Place Martin, Michigan Zip 49070 Product Solar, Wind Year founded 2004 Phone number (269) 672-9620 Website http://www.bauerpower.com/inde Coordinates 42.5411327°, -85.6622567° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.5411327,"lon":-85.6622567,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

419

Metso Power | Open Energy Information  

Open Energy Info (EERE)

Metso Power Metso Power Jump to: navigation, search Logo: Metso Power Name Metso Power Address 3430 Toringdon Way, Suite 201 Place Charlotte, North Carolina Zip 28277 Sector Biofuels Product Boilers for waste and biofuels Phone number 1-877-311-0101 Website http://www.metsopowerservice.c Coordinates 35.068081°, -80.84282° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":35.068081,"lon":-80.84282,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

420

Makani Power | Open Energy Information  

Open Energy Info (EERE)

Makani Power Makani Power Jump to: navigation, search Name Makani Power Address 2175 Monarch Street Place Alameda, California Zip 94501 Sector Wind energy Product High-altitude wind power generation Website http://www.makanipower.com/ Coordinates 37.7831775°, -122.3086191° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.7831775,"lon":-122.3086191,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

CMNA Power | Open Energy Information  

Open Energy Info (EERE)

CMNA Power CMNA Power Jump to: navigation, search Name CMNA Power Address 12303 Technology Blvd Place Austin, Texas Zip 78727 Sector Wind energy Product Developing non-turbine wind power technology Website http://www.cmnapower.com/ Coordinates 30.434942°, -97.759544° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":30.434942,"lon":-97.759544,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

422

Element Power | Open Energy Information  

Open Energy Info (EERE)

Power Power Jump to: navigation, search Logo: Element Power Name Element Power Address 421 SW Sixth Avenue, Suite 1000 Place Portland, Oregon Zip 97204 Sector Wind energy Product uility-scale solar and wind projects Website http://www.elpower.com/ Coordinates 45.520812°, -122.67791° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":45.520812,"lon":-122.67791,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

423

Silent Power | Open Energy Information  

Open Energy Info (EERE)

Silent Power Silent Power Jump to: navigation, search Logo: Silent Power Name Silent Power Address 8175 Industrial Park Rd Place Baxter, Minnesota Zip 56425 Sector Efficiency Product OnDemand Energy Appliance Year founded 2002 Number of employees 11-50 Phone number 2184543030 Website http://www.silentpwr.com/ Coordinates 46.3493314°, -94.2337496° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":46.3493314,"lon":-94.2337496,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

424

Celestial Power | Open Energy Information  

Open Energy Info (EERE)

Celestial Power Celestial Power Jump to: navigation, search Logo: Celestial Power Name Celestial Power Address 1012 Hermitage Drive Place Austin, Texas Zip 78753 Sector Solar Product Solar energy contractor Number of employees 1-10 Website http://celestialpower.biz/ Coordinates 30.34801°, -97.688504° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":30.34801,"lon":-97.688504,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

425

People Power | Open Energy Information  

Open Energy Info (EERE)

People Power People Power Jump to: navigation, search Logo: People Power Name People Power Address 620 Lowell Street Place East Palo Alto, California Zip 94301 Sector Efficiency Product Home Area Network Year founded 2009 Number of employees 11-50 Phone number 415-902-8395 Website http://www.peoplepowerco.com/ Coordinates 37.4403239°, -122.142355° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.4403239,"lon":-122.142355,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

426

Regrid Power | Open Energy Information  

Open Energy Info (EERE)

Regrid Power Regrid Power Jump to: navigation, search Name Regrid Power Place Campbell, California Zip 95008 Sector Renewable Energy, Services, Solar Product REgrid Power is a renewable energy design, installation, and services company which is specialised in solar photovoltaic systems. Coordinates 33.14919°, -95.951444° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":33.14919,"lon":-95.951444,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

427

QM Power | Open Energy Information  

Open Energy Info (EERE)

QM Power QM Power Jump to: navigation, search Name QM Power Place Boston, Massachusetts Zip 2115 Product QM Power is a developer of motors, generators and actuators for electromagnetic applications. Coordinates 42.358635°, -71.056699° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.358635,"lon":-71.056699,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

428

JJR Power | Open Energy Information  

Open Energy Info (EERE)

JJR Power JJR Power Jump to: navigation, search Name JJR Power Place Excelsior, Minnesota Zip 55331 Sector Solar, Wind energy Product Engaged in solar and wind power financing and development. Coordinates 44.902825°, -93.568644° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":44.902825,"lon":-93.568644,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

429

Power County | Open Energy Information  

Open Energy Info (EERE)

County County Jump to: navigation, search Name Power County Facility Power County Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Owner CG Power Solutions Developer CG Power Solutions Energy Purchaser PacifiCorp Location American Falls ID Coordinates 42.66135774°, -112.9727554° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.66135774,"lon":-112.9727554,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

430

Allegheny Power | Open Energy Information  

Open Energy Info (EERE)

Power Power Jump to: navigation, search Name Allegheny Power Address 800 Cabin Hill Drive Place Greensburg, Pennsylvania Zip 15601 Sector Services Product Green Power Marketer Website http://www.alleghenypower.com/ Coordinates 40.3178006°, -79.5457953° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.3178006,"lon":-79.5457953,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

431

Power Flow Controller for Renewables: Transformer-less Unified Power Flow Controller for Wind and Solar Power Transmission  

SciTech Connect

GENI Project: MSU is developing a power flow controller to improve the routing of electricity from renewable sources through existing power lines. The fast, innovative, and lightweight circuitry that MSU is incorporating into its controller will eliminate the need for a separate heavy and expensive transformer, as well as the construction of new transmission lines. MSUs controller is better suited to control power flows from distributed and intermittent wind and solar power systems than traditional transformer-based controllers are, so it will help to integrate more renewable energy into the grid. MSUs power flow controller can be installed anywhere in the existing grid to optimize energy transmission and help reduce transmission congestion.

None

2012-02-08T23:59:59.000Z

432

Clean Power at Home  

E-Print Network (OSTI)

this report is to describe and analyze net metering as a mechanism to support the deployment of small-scale, distributed electricity technologies in British Columbia based on renewable energy sources. These are referred to as "distributed renewables" throughout the report. The deployment of distributed renewables offers several environmental, economic, and social benefits that are described in this paper. Net metering enables individual utility customers to connect on-site generation to the utility grid, feeding excess power back to the grid when it is not needed, and utilizing grid power when consumption exceeds local renewable energy supply. In most programs, a single meter measures the customer's net consumption of grid power in a billing period, and they are charged for that consumption under regular retail rates. If production exceeds consumption, the customer's bill is essentially zero. In some instances, utilities may refund customers for excess production in a billing period based on wholesale market prices or avoided production costs. Net metering programs can make self-generation more attractive for customers by eliminating the need to size systems to meet customers' exact power needs or install on-site storage and power conditioning devices. Utilities may, depending upon the type of systems installed, benefit from improvements in local area load factors, and receive credit for various social or environmental benefits of such resources (e.g., greenhouse gas reductions). However, utilities have raised concerns about worker safety (e.g., the possibility that net metering sites may continue to feed electricity into the local distribution grid when the rest of the network is down, putting line workers at risk) and possible financial cross-subsidies from other rate...

May Author Andrew; Andrew E. Pape

433

Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Power Right. Power Smart. Efficient Computer Power Supplies and Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. March 10, 2009 - 6:00am Addthis John Lippert Power supplies convert the AC power that you get from your electric company into the DC power consumed by most electronics, including your computer. We expect our power supplies to be safe, reliable, and durable. If they meet those criteria, then they're all alike, except for cost, right? Well, not exactly. You see, there's one other important feature that sets them apart: efficiency. And I don't know about you, but I believe waste is bad. For me, high efficiency is one important feature that's needed for something to be high quality. So isn't it ridiculous that most power

434

Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Power Right. Power Smart. Efficient Computer Power Supplies and Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. Power Right. Power Smart. Efficient Computer Power Supplies and Monitors. March 10, 2009 - 6:00am Addthis John Lippert Power supplies convert the AC power that you get from your electric company into the DC power consumed by most electronics, including your computer. We expect our power supplies to be safe, reliable, and durable. If they meet those criteria, then they're all alike, except for cost, right? Well, not exactly. You see, there's one other important feature that sets them apart: efficiency. And I don't know about you, but I believe waste is bad. For me, high efficiency is one important feature that's needed for something to be high quality. So isn't it ridiculous that most power

435

Star Power  

SciTech Connect

The U.S. Department of Energy's Princeton Plasma Physics Laboratory has released ''Star Power,'' a new informational video that uses dramatic and beautiful images and thought-provoking interviews to highlight the importance of the Laboratory's research into magnetic fusion.

None

2014-10-17T23:59:59.000Z

436

Solar Power  

Science Journals Connector (OSTI)

...of desert solar energy farm with 30 percent conversion...85 percent of the solar farm energy now reflected back...Washington, D.C. 20550. Wind Power Martin Wolf (19...counting the cost of the offshore platforms, would thus...15 billion. If these wind generators were placed...

Paul E. Damon

1974-08-09T23:59:59.000Z

437

Star Power  

ScienceCinema (OSTI)

The U.S. Department of Energy's Princeton Plasma Physics Laboratory has released ''Star Power,'' a new informational video that uses dramatic and beautiful images and thought-provoking interviews to highlight the importance of the Laboratory's research into magnetic fusion.

None

2014-11-18T23:59:59.000Z

438

Solar Power | Open Energy Information  

Open Energy Info (EERE)

Solar Power Solar Power (Redirected from Solar energy) Jump to: navigation, search Solar Energy Companies Loading map... {"format":"googlemaps3","type":"SATELLITE","types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"limit":1000,"offset":0,"link":"all","sort":[""],"order":[],"headers":"show","mainlabel":"","intro":"","outro":"","searchlabel":"\u2026 further results","default":"","geoservice":"google","zoom":false,"width":"99%","height":"300px","centre":false,"layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":true,"searchmarkers":"","icon":"","visitedicon":"","forceshow":true,"showtitle":true,"hidenamespace":false,"template":false,"title":"","label":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"locations":[{"text":"

439

Solar Power | Open Energy Information  

Open Energy Info (EERE)

Solar Power Solar Power Jump to: navigation, search Solar Energy Companies Loading map... {"format":"googlemaps3","type":"SATELLITE","types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"limit":1000,"offset":0,"link":"all","sort":[""],"order":[],"headers":"show","mainlabel":"","intro":"","outro":"","searchlabel":"\u2026 further results","default":"","geoservice":"google","zoom":false,"width":"99%","height":"300px","centre":false,"layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":true,"searchmarkers":"","icon":"","visitedicon":"","forceshow":true,"showtitle":true,"hidenamespace":false,"template":false,"title":"","label":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"locations":[{"text":"

440

Hydrogen Power Inc formerly Hydrogen Power International and Equitex Inc |  

Open Energy Info (EERE)

Power Inc formerly Hydrogen Power International and Equitex Inc Power Inc formerly Hydrogen Power International and Equitex Inc Jump to: navigation, search Name Hydrogen Power, Inc. (formerly Hydrogen Power International and Equitex Inc.) Place Englewood, Colorado Zip 80111 Sector Hydro, Hydrogen Product Holding company operating through its majority owned subsidiaries, Hydrogen Power International, FastFunds Financial Corp and Denaris Corp. Coordinates 35.425805°, -84.487497° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":35.425805,"lon":-84.487497,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

A Merged two-stage power conversion architecture with switched capacitor circuit for an LED driver module  

E-Print Network (OSTI)

In a power converter specified to convert from wide-range and high-level DC voltage or AC line voltage to low-level DC voltage, satisfying high efficiency, high power density, and high power factor is challenging because ...

Lim, Seungbum

2012-01-01T23:59:59.000Z

442

2005 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE  

U.S. Energy Information Administration (EIA) Indexed Site

Page 1 Page 1 2012 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE Kerosene Line No. Sold directly to consumers for: 1 Residential Use (Non-Farm): * Backup generator * Home heating and cooking * Personal lawn equipment * EXCLUDE: Apartment buildings and Farmhouses 2 Commercial Use: * Apartment building * Bank * Casino * Church * College/School/Institution * Department/Retail store * Environmental clean-up service * Flushing fuel lines * Forestry service * Golf course * Government (Federal, State, local, and district; INCLUDE fuel used in vehicles) * Hazardous waste company * Hospital * Hotel/Motel * Landfill site government owned * Landscaping * Laundry company * Lumber yard that sells the lumber * Medical service * Port Authority/publicly owned port or loading dock

443

2013 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE  

Annual Energy Outlook 2012 (EIA)

waste company * Hospital * HotelMotel * Landfill site government owned (exclude private landfill, see Off-highway, as defined on page 3 for Lines 41 through 43) *...

444

112 Home Power #72 August / September 1999 Code Corner  

E-Print Network (OSTI)

and ungrounded electrical systems can be safe. Europeans have a 100 year tradition of operating ungrounded electrical power systems, and European codes reflect this. The European Community also makes use of double subjected to surges on utility power lines. In addition, systems using PV power to run computers

Johnson, Eric E.

445

Programming Project : Admittance Matrix and Power/Load-Flow  

E-Print Network (OSTI)

Programming Project : Admittance Matrix and Power/Load-Flow EE 581 April 19, 2012 1 Introduction This project will be to develop your own power-flow (also known as load-flow) solver to study balanced, three-phase power systems in sinusoidal steady-state. The program will read in data from three files (bus, line

Wedeward, Kevin

446

PowerSystemsSimulation NSERC Industrial Research Chair in  

E-Print Network (OSTI)

, Aalborg Univ. and Univ. of Manitoba, email:skc@et.aau.dk A 400MW offshore wind power plant has been an offshore wind power plant to an onshore grid. To develop a PSCAD/EMTDC simulation model of an offshore WPP Faults in the Offshore Wind Power Grid System Layout and Single Line Diagram Main Objectives: VSC

Chaudhary, Sanjay

447

Power Factor Compensation (PFC) Power Factor Compensation  

E-Print Network (OSTI)

Power Factor Compensation (PFC) Power Factor Compensation The power factor (PF) is defined as the ratio between the active power and the apparent power of a system. If the current and voltage are periodic with period , and [ ), then the active power is defined by ( ) ( ) (their inner product

Knobloch,Jürgen

448

PowerPoint Presentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Year 5/13-5/14 2003 Year 5/13-5/14 2003 Jim Irby MIT-PSFC 5 Year 5/13-5/14 2003 Outline * Alcator C-Mod Facility * Recent accomplishments - Mods/Upgrades - Inspections - MIT Support * Five Year Plan - Upgrades - Data system - Diagnostics * Statistics * Summary 5 Year 5/13-5/14 2003 Alcator C-Mod Facility Power Sources * 13.8 kV, 24 MVA line from NSTAR - Alternator drive - ICRF transmitters - LH sources - EFC, EF2 magnets * Alternator - 125 ton, 4 pole rotor - 1800 RPM - 2 GJ stored energy (72 ton flywheel) - 200 MW loads with 500 MJ extracted 5 Year 5/13-5/14 2003 5 Year 5/13-5/14 2003 ICRF Systems * 2 transmitters at 80 MHz, 2 MW CW each * 2 transmitters tunable from 40 to 80 MHz, 2 MW CW each * 2 two-strap antennas, 1.5 MW each * 1 four-strap antenna, 3 MW 5 Year 5/13-5/14 2003 Other Major Systems * 11 power supplies power 14 magnets

449

Powerful glow discharge excilamp  

DOE Patents (OSTI)

A powerful glow discharge lamp comprising two coaxial tubes, the outer tube being optically transparent, with a cathode and anode placed at opposite ends of the tubes, the space between the tubes being filled with working gas. The electrodes are made as cylindrical tumblers placed in line to one other in such a way that one end of the cathode is inserted into the inner tube, one end of the anode coaxially covers the end of the outer tube, the inner tube penetrating and extending through the anode. The increased electrodes' surface area increases glow discharge electron current and, correspondingly, average radiation power of discharge plasma. The inner tube contains at least one cooling liquid tube placed along the axis of the inner tube along the entire lamp length to provide cathode cooling. The anode has a circumferential heat extracting radiator which removes heat from the anode. The invention is related to lighting engineering and can be applied for realization of photostimulated processes under the action of powerful radiation in required spectral range.

Tarasenko, Victor F. (Tomsk, RU); Panchenko, Aleksey N. (Tomsk, RU); Skakun, Victor S. (Tomsk, RU); Sosnin, Edward A. (Tomsk, RU); Wang, Francis T. (Danville, CA); Myers, Booth R. (Livermore, CA); Adamson, Martyn G. (Danville, CA)

2002-01-01T23:59:59.000Z

450

GEOTHERMAL POWER GENERATION PLANT  

SciTech Connect

Oregon Institute of Technology (OIT) drilled a deep geothermal well on campus (to 5,300 feet deep) which produced 196oF resource as part of the 2008 OIT Congressionally Directed Project. OIT will construct a geothermal power plant (estimated at 1.75 MWe gross output). The plant would provide 50 to 75 percent of the electricity demand on campus. Technical support for construction and operations will be provided by OITs Geo-Heat Center. The power plant will be housed adjacent to the existing heat exchange building on the south east corner of campus near the existing geothermal production wells used for heating campus. Cooling water will be supplied from the nearby cold water wells to a cooling tower or air cooling may be used, depending upon the type of plant selected. Using the flow obtained from the deep well, not only can energy be generated from the power plant, but the waste water will also be used to supplement space heating on campus. A pipeline will be construction from the well to the heat exchanger building, and then a discharge line will be construction around the east and north side of campus for anticipated use of the waste water by facilities in an adjacent sustainable energy park. An injection well will need to be drilled to handle the flow, as the campus existing injection wells are limited in capacity.

Boyd, Tonya

2013-12-01T23:59:59.000Z

451

Millihertz QPOs and broad iron line from LMC X-1  

E-Print Network (OSTI)

We study the temporal and energy spectral characteristics of the persistent black hole X-ray binary LMC X-1 using two XMM-Newton and a Suzaku observation. We report the discovery of low frequency (~ 26-29 mHz) quasi-periodic oscillations (QPOs). We also report the variablity of the broad iron K-alpha line studied earlier with Suzaku. The QPOs are found to be weak with fractional rms amplitude in the ~ 1-2 % range and quality factor Q~2-10 . They are accompanied by weak red noise or zero-centered Lorentzian components with rms variability at the ~ 1-3 % level. The energy spectra consists of three varying components - multicolour disk blackbody (kT_{in} ~ 0.7-0.9 keV), high energy power-law tail (Gamma ~ 2.4 - 3.3) and a broad iron line at 6.4-6.9 keV. The broad iron line, the QPO and the strong power-law component are not always present. The QPOs and the broad iron line appear to be clearly detected in the presence of a strong power-law component. The broad iron line is found to be weaker when the disk is like...

Alam, Md Shah; Belloni, T; Mukherjee, D; Jhingan, S

2014-01-01T23:59:59.000Z

452

Bipolar pulse forming line  

DOE Patents (OSTI)

A bipolar pulse forming transmission line module for linear induction accelerators having first, second, third, fourth, and fifth planar conductors which form an interleaved stack with dielectric layers between the conductors. Each conductor has a first end, and a second end adjacent an acceleration axis. The first and second planar conductors are connected to each other at the second ends, the fourth and fifth planar conductors are connected to each other at the second ends, and the first and fifth planar conductors are connected to each other at the first ends via a shorting plate adjacent the first ends. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short a high voltage from the first end of the third planar conductor to the first end of the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

Rhodes, Mark A. (Pleasanton, CA)

2008-10-21T23:59:59.000Z

453

EIS-0124: Conrad-Shelby Transmission Line Project, Montana  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy's Western Area Power Administration developed this statement to assess the environmental impact of adding a 230 kV transmission line between Conrad and Shelby, Montana and a new substation near Shelby to update the stressed electrical transmission system.

454

EIS-0499: Great Northern Transmission Line Project, Minnesota  

Energy.gov (U.S. Department of Energy (DOE))

This EIS will evaluate the potential environmental impacts of a DOE proposal to grant a Presidential permit to Minnesota Power to construct, operate, maintain, and connect a new 750-megawatt electric transmission system across the U.S.-Canada border. The proposed 220 mile transmission line would cross the border near Roseau, Minnesota, and continue to Grand Rapids, Minnesota.

455

Homeowners: Respond to Power Outages | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Power Outages Power Outages Homeowners: Respond to Power Outages Homeowners: Respond to Power Outages After a disaster, electric utilities and government officials will first work to restore power to critical infrastructure like power plants and transmission lines, water treatment facilities, and telecommunications networks, and also to hospitals, critical care facilities, and emergency response agencies. It may take several days or even weeks to restore power to individual homeowners, but here's what you can do to help prepare and recover power more quickly: Charge mobile devices-If you have power, charge your cell phones, laptops, and other mobile devices so they'll have the maximum amount of battery power stored in the event of a power outage. These devices will help you communicate with your power company, and they'll help you stay

456

Situ soil sampling probe system with heated transfer line  

DOE Patents (OSTI)

The present invention is directed both to an improved in situ penetrometer probe and to a heated, flexible transfer line. The line and probe may be implemented together in a penetrometer system in which the transfer line is used to connect the probe to a collector/analyzer at the surface. The probe comprises a heater that controls a temperature of a geologic medium surrounding the probe. At least one carrier gas port and vapor collection port are located on an external side wall of the probe. The carrier gas port provides a carrier gas into the geologic medium, and the collection port captures vapors from the geologic medium for analysis. In the transfer line, a flexible collection line that conveys a collected fluid, i.e., vapor, sample to a collector/analyzer. A flexible carrier gas line conveys a carrier gas to facilitate the collection of the sample. A system heating the collection line is also provided. Preferably the collection line is electrically conductive so that an electrical power source can generate a current through it so that the internal resistance generates heat.

Robbat, Jr., Albert (Andover, MA)

2002-01-01T23:59:59.000Z

457

Grand Valley Rrl Pwr Line, Inc | Open Energy Information  

Open Energy Info (EERE)

Pwr Line, Inc Pwr Line, Inc Jump to: navigation, search Name Grand Valley Rrl Pwr Line, Inc Place Colorado Utility Id 7563 Utility Location Yes Ownership C NERC Location WECC NERC WECC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial and Small Power Service, Three Phase Schedule (25)-CSP-1 Commercial Farm and Home (Residential) Service Schedule (10)-FH-1 Residential Industrial Service Schedule (50) -IND-1 Industrial Irrigation Service Schedule (40)-I-1 Commercial Large Power Service Schedule (30) -LP-1 Industrial Nonresidential - General Schedule (20)-NRG-1 Commercial

458

Libby-Troy Line Rebuild Project - July 25, 2008  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Libby to Troy Rebuild Project 1 Libby to Troy Rebuild Project 1 Record of Decision July 2008 Bonneville Power Administration Rebuild of the Libby (FEC) to Troy Section of BPA's Libby to Bonners Ferry 115-kilovolt Transmission Line Project Record of Decision July 2008 Decision The Bonneville Power Administration (BPA) has decided to implement the Proposed Action with the Kootenai River Crossing realignment option that was identified in the Rebuild of the Libby (FEC) to Troy Section of BPA's Libby to Bonners Ferry 115-kilovolt Transmission Line Project Final Environmental Impact Statement (DOE/EIS-0379, May 2008). To implement this alternative, BPA will rebuild the 17-mile-long Libby-Troy section of the existing transmission line at the same voltage (115 kilovolt (kV)) with the same number of circuits (one). BPA will

459

Analysis of interconnect microstrip lines  

E-Print Network (OSTI)

System C. Dyadic Green's Functions 1. TM and TE Decomposition 2. Transmission-Line Green's Functions . NUiVIERICAL PROCEDURES . A. Basis functions and testing procedure . 1. Interconnect of Microstrip Lines 2. Slot-Coupled Microstrip Dipole . 3... data of return loss on the 20 GHz slot-coupled rect- angular patch antenna. . FIG URE Pa. ge 28 Typical transmission line section containing a 1A current source. . . 68 CHAPTER I INTRODUCTION Many studies on slot-coupled microstrip antennas have...

Luong, Giam-Minh

2012-06-07T23:59:59.000Z

460

Power superconducting power transmission cable  

DOE Patents (OSTI)

The present invention is for a compact superconducting power transmission cable operating at distribution level voltages. The superconducting cable is a conductor with a number of tapes assembled into a subconductor. These conductors are then mounted co-planarly in an elongated dielectric to produce a 3-phase cable. The arrangement increases the magnetic field parallel to the tapes thereby reducing ac losses.

Ashworth, Stephen P. (Cambridge, GB)

2003-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Testing in Software Product Lines.  

E-Print Network (OSTI)

??This thesis presents research aimed at investigating different activities involved in software product lines testing process and possible improvements towards achieving developing high quality software (more)

Odia, Osaretin

2007-01-01T23:59:59.000Z

462

NETL LINES OF DEMARCATION 09282012  

NLE Websites -- All DOE Office Websites (Extended Search)

LINES OF DEMARCATION September 28, 2012 Contact: Site Operations Division or ESS&H Division with Questions The oversight, upkeep, and segregation of NETL infrastructure components,...

463

Power Search  

NLE Websites -- All DOE Office Websites (Extended Search)

You are here: Find a Car Home > Power Search You are here: Find a Car Home > Power Search Power Search Expand any feature by selecting its title bar. Choose as many or as few features as you like. Model Year From: 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 2005 2004 2003 2002 2001 2000 1999 1998 1997 1996 1995 1994 1993 1992 1991 1990 1989 1988 1987 1986 1985 1984 To: 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 2005 2004 2003 2002 2001 2000 1999 1998 1997 1996 1995 1994 1993 1992 1991 1990 1989 1988 1987 1986 1985 1984 MSRP Under $15,000 $15,000-$20,000 $20,000-$25,000 $25,000-$30,000 $30,000-$35,000 $35,000-$40,000 $40,000-$45,000 $45,000-$50,000 $50,000-$55,000 $55,000-$60,000 $60,000-$65,000 $65,000-$70,000 $70,000-$75,000 $75,000-$80,000 $80,000-$85,000 Over $85,000 - OR - Minimum: Select... $5,000 $6,000 $7,000 $8,000 $9,000 $10,000 $11,000

464

Village Power `97. Proceedings  

SciTech Connect

It is estimated that two billion people live without electricity and its services. In addition, there is a sizable number of rural villages that have limited electrical service, with either part-day operation by diesel gen-sets or partial electrification (local school or community center and several nearby houses). For many villages connected to the grid, power is often sporadically available and of poor quality. The U.S. National Renewable Energy Laboratory (NREL) in Golden, Colorado, has initiated a program to address these potential electricity opportunities in rural villages through the application of renewable energy (RE) technologies. The objective of this program is to develop and implement applications that demonstrate the technical performance, economic competitiveness, operational viability, and environmental benefits of renewable rural electric solutions, compared to the conventional options of line extension and isolated diesel mini-grids. These four attributes foster sustainability; therefore, the program is entitled Renewables for Sustainable Village Power (RSVP). The RSVP program is a multi-disciplinary, multi-technology, multi-application program composed of six key activities, including village application development, computer model development, systems analysis, pilot project development, technical assistance, and an Internet-based village power project database. The current program emphasizes wind, photovoltaics (PV), and their hybrids with diesel gen-sets. NREL`s RSVP team is currently involved in rural electricity projects in thirteen countries, with U.S., foreign, and internationally based agencies and institutions. This document contains reports presented at the Proceedings of Village Power, 1997. Individual projects have been processed separately for the United States Department of Energy databases.

Cardinal, J.; Flowers, L.; Taylor, R.; Weingart, J. [eds.

1997-09-01T23:59:59.000Z

465

Power Right. Power Smart. Efficient Computer Power Supplies and...  

Energy Savers (EERE)

lot of the electricity they consume? Higher efficiency power supplies reduce energy consumption, thus cutting your electricity bill. They reduce power consumption, helping your...

466

Productivity Improvement of a Manual Assembly Line  

E-Print Network (OSTI)

or re-configuring an assembly system, which is the key step in improving the overall performance of an assembly line. Following this approach, two manual assembly line configurations (single stage parallel line and five-stage serial line...

Yerasi, Pranavi

2012-10-19T23:59:59.000Z

467

Comments on RFI on Permitting of Transmission Lines Available | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Comments on RFI on Permitting of Transmission Lines Available Comments on RFI on Permitting of Transmission Lines Available Comments on RFI on Permitting of Transmission Lines Available April 3, 2012 - 2:12pm Addthis On October 5, 2011, the White House announced the creation of a Rapid Response Team for Transmission (RRTT). In support of the RRTT the Department of Energy's Office of Electricity Delivery and Energy Reliability released a Federal Register Notice seeking information on questions related to permitting of transmission lines. The Request for Information focused on making the development times for generation and transmission more commensurate with one another. Public comments received from the following organizations are now available for review and downloading. - Allegheny Highlands Alliance - American Electric Power

468

Single transmission line interrogated multiple channel data acquisition system  

DOE Patents (OSTI)

A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensor circuits each monitors a specific process variable and each transmits measurement values over a single transmission line to a master interrogating station when addressed by said master interrogating station. Typically, as many as 330 remote stations may be parallel connected to the transmission line which may exceed 7,000 feet. The interrogation rate is typically 330 stations/second. The master interrogating station samples each station according to a shared, charging transmit-receive cycle. All remote station address signals, all data signals from the remote stations/sensors and all power for all of the remote station/sensors are transmitted via a single continuous terminated coaxial cable. A means is provided for periodically and remotely calibrating all remote sensors for zero and span. A provision is available to remotely disconnect any selected sensor station from the main transmission line.

Fasching, George E. (Morgantown, WV); Keech, Jr., Thomas W. (Morgantown, WV)

1980-01-01T23:59:59.000Z

469

20120131 DOE Congestion Study Clean Line Comments 2012  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

UNITED STATES DEPARTMENT OF ENERGY UNITED STATES DEPARTMENT OF ENERGY OFFICE OF ELECTRICITY DELIVERY AND ENERGY RELIABILITY 2012 NATIONAL ELECTRIC TRANSMISSION CONGESTION STUDY COMMENTS OF CLEAN LINE ENERGY PARTNERS LLC January 31, 2012 Clean Line Energy Partners LLC ("Clean Line") respectfully submits these comments in response to the Department of Energy's ("DOE") Plan for Conduct of 2012 Electric Transmission Congestion Study ("Congestion Study") as published in the Federal Register on November 11, 2011. Clean Line appreciates the DOE's renewed efforts to gather and review existing and new transmission data across the nation (as per 76 FR 70122) to develop a list of congestion areas that may be eligible for backstop authority under 216a of the Federal Power

470

A Partitioning Approach for Parallel Simulation of AC-Radial Shipboard Power Systems  

E-Print Network (OSTI)

be used. That is, a transmission line of sufficient physical length must exist in order to partition power systems. If said line does not exist in the power system being modeled, short-lines (stublines [27]) with one time step delay can be used... the electrical network equations using modified nodal analysis, use Bergeron?s travelling-wave transmission line model to create subsystems, and to parallelize the simulation using a distributed computer. In this work, an SPS was formulated using loop...

Uriarte, Fabian Marcel

2011-08-08T23:59:59.000Z

471

EIS-0159: Flatiron-Erie 115-kV Transmission Line  

Energy.gov (U.S. Department of Energy (DOE))

"The Western Area Power Administration proposes to build 27 new wood H-frame structures along the line, to replace or modify 45 of the existing structures and to remove 11 of them."

472

EA-1952: Lane-Wendson No. 1 Transmission Line Rebuild Project; Lane County, Oregon  

Energy.gov (U.S. Department of Energy (DOE))

Bonneville Power Administration is preparing an EA to assess the potential environmental impacts of the proposed rebuild of the 41.3-mile Lane-Wendson No. 1 transmission line between Eugene and Florence, Oregon.

473

EIS-0078: Jonesboro-Hergett 161-kV Transmission Line  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy's Southwestern Power Administration developed this statement to assess the environmental and socioeconomic impacts of a 161-kilovolt transmission line in Craighead County, Arkansas, including its proposed and alternate routes.

474

Polarizer with Nonrectangular Grooves in the HE11 Mode Transmission Line  

Science Journals Connector (OSTI)

This paper presents experimental results on polarizers with nonrectangular grooves to be used in high power millimeter wave transmission lines for electron cyclotron heating (ECH) of fusion plasmas. A low-powe...

K. Nagasaki; Y. Itoh; H. Morioka; T. Obiki

1999-05-01T23:59:59.000Z

475

PowerPoint Presentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Neutron Scattering Neutron Scattering Bruce D. Gaulin * Magnetism and Neutron Scattering - A Killer Application * Magnetism in Solids * Bottom lines on magnetic neutron scattering * Examples C. G. Shull et al, 1951 Magnetic Structure of MnO Paramagnet Ferromagnet Antiferromagnet T>T C Tpowerful probe of magnetism in solids! d-electrons: 10 levels to fill 4f 14 levels 5f Magnetism = Net Angular Momentum e g orbitals t 2g orbitals e g orbitals t 2g orbitals 3d 5 : Mn 2+ e g orbitals t 2g orbitals 3d 9 : Cu 2+ Superexchange Interactions in Magnetic Insulators RKKY exchange in Itinerant Magnets (eg. Rare Earth Metals)

476

PowerPoint Presentation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tribal Leader Forum Series Feb 7-8 2012 Tribal Leader Forum Series Feb 7-8 2012 Transmission Basics Facilities, Interconnection and Permitting Laurie A. Woodall Esq. Laurie.Woodall@URS.com 602 648 2385 Office 480 291 3522 Mobile 2 Tribal Leader Forum Series Feb 7-8 2012 Overview * Basics regarding electrical system * Basics of transmission planning * Basics regarding interconnection * Basics of typical siting/state permitting processes for transmission lines 3 Tribal Leader Forum Series Feb 7-8 2012 Useful Links * EEI siting directory of agencies http://www.eei.org/ourissues/ElectricityTransmission/Documents/ State_Generation_Transmission_Siting_Directory.pdf * OSHA illustrated glossary of electrical components http://www.osha.gov/SLTC/etools/electric_power/illustrated_gloss ary/index.html

477

PowerPoint Presentation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ISO New England Comments on the ISO New England Comments on the National Electric Transmission Congestion Study Department of Energy Workshop Philadelphia, PA December 6, 2011 Michael I. Henderson Director Regional Planning and Coordination, System Planning DOE Workshop - December 6, 2011 © 2011 ISO New England Inc. Key Facts About New England's Electric Power System and Wholesale Electricity Markets 2 6.5 million households and businesses; population 14 million Over 300 generators totaling 32,000 MW of capacity Over 8,000 miles of transmission lines 13 interconnections to electricity systems in New York and Canada 2,035 MW of demand-resources All-time peak demand of 28,130 MW, set on August 2, 2006 More than 450 participants in the marketplace (those who generate, buy, sell, transport, and use wholesale

478

SunLine Transit Agency  

Energy.gov (U.S. Department of Energy (DOE))

SunLine Transit Agency provides public transit and community services to California's Coachella Valley. The service area is more than 1,100 square miles and includes nine member cities, as well as Riverside County. Over the years, SunLine has pursued an aggressive strategy for implementing clean technologies into its fleet.

479

8th International Conference on Probability Methods Applied to Power Systems, Ames Iowa, September 2004 Estimating Failure Propagation in Models of  

E-Print Network (OSTI)

and a power systems blackout model of cascading transmission line overloads. The comparisons suggest stage. OPA is a power system blackout model that represents probabilistic cascading line outages. The initial disturbance is generated by random line outages and load variations. Overloaded lines outage

480

Wind power and Wind power and  

E-Print Network (OSTI)

Wind power and the CDM #12; Wind power and the CDM Emerging practices in developing wind power 2005 Jyoti P. Painuly, Niels-Erik Clausen, Jørgen Fenhann, Sami Kamel and Romeo Pacudan #12; WIND POWER AND THE CDM Emerging practices in developing wind power projects for the Clean Development Mechanism Energy

Note: This page contains sample records for the topic "overhead power lines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Power Recovery  

E-Print Network (OSTI)

) - 2,870,000 x 0.8 6 W - 3414 = 70 kw (or 900 hp). When recovering power from an expanding gas, consideration should be given to the final gas temperature. This tem;:>f'rature can be estimated by the formula: T 2 Final temperature, oR. Other... with the requirements make generation fqr more useful. Presently a recovery level of around 500 kw (or 657 hp) appears to be the minimum level which will support an in stallation. In order to achieve reasonable effi ciency, quality equipment with good control...

Murray, F.

482

Nth Power | Open Energy Information  

Open Energy Info (EERE)

Nth Power Nth Power Jump to: navigation, search Name Nth Power Address One Embarcadero Center Place San Francisco, California Zip 94111 Region Bay Area Product Cleantech venture fund Website http://www.nthpower.com/ Coordinates 37.794891°, -122.397901° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.794891,"lon":-122.397901,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

483

IW Power | Open Energy Information  

Open Energy Info (EERE)

IW Power IW Power Jump to: navigation, search Name IW Power Place Hangzhou, Zhejiang Province, China Zip 310007 Sector Wind energy Product Joint venture wind project development firm. Coordinates 30.252501°, 120.165024° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":30.252501,"lon":120.165024,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

484

Primus Power | Open Energy Information  

Open Energy Info (EERE)

Primus Power Primus Power Jump to: navigation, search Name Primus Power Place Alameda, California Product California based energy storage company focusing on low-cost battery technology. Coordinates 37.766585°, -122.244739° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.766585,"lon":-122.244739,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

485

Achates Power | Open Energy Information  

Open Energy Info (EERE)

Achates Power Achates Power Jump to: navigation, search Name Achates Power Address 4060 Sorrento Valley Boulevard Place San Diego, California Zip 92121 Sector Vehicles Product Developing a fuel-efficient, cleaner-burning diesel engine Website http://www.achatespower.com/ Coordinates 32.904435°, -117.218137° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":32.904435,"lon":-117.218137,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

486

Plankton Power | Open Energy Information  

Open Energy Info (EERE)

Plankton Power Plankton Power Jump to: navigation, search Name Plankton Power Place Wellfleet, Massachusetts Product Massachusetts-based algae biofuel start-up company. Coordinates 40.752775°, -100.725684° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.752775,"lon":-100.725684,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

487

Tenderland Power | Open Energy Information  

Open Energy Info (EERE)

Tenderland Power Tenderland Power Jump to: navigation, search Name Tenderland Power Place Seattle, Washington Zip 98101 Sector Biomass, Hydro, Renewable Energy, Solar, Wind energy Product Utility which provides electricity, generated from renewable energy sources such as wind, solar, biomass and hydroelectric. Coordinates 47.60356°, -122.329439° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":47.60356,"lon":-122.329439,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

488

Concentrating Solar Power: Technology Overview  

SciTech Connect

Concentrating Solar Power (CSP) has the potential to contribute significantly to the generation of electricity by renewable energy resources in the U.S.. Thermal storage can extend the duty cycle of CSP beyond daytime hours to early evening where the value of electricity is often the highest. The potential solar resource for the southwest U.S. is identified, along with the need to add power lines to bring the power to consumers. CSP plants in the U.S. and abroad are described. The CSP cost of electricity at the busbar is discussed. With current incentives, CSP is approaching competiveness with conventional gas-fired systems during peak-demand hours when the price of electricity is the highest. It is projected that a mature CSP industry of over 4 GWe will be able to reduce the energy cost by about 50%, and that U.S. capacity could be 120 GW by 2050.

Mehos, M.

2008-01-01T23:59:59.000Z

489

Georgia Power | Open Energy Information  

Open Energy Info (EERE)

Power Power Jump to: navigation, search Name Georgia Power Place Atlanta, Georgia Zip 30308 Product An investor-owned utility that serves 2.25m customers in 155 counties of Georgia, USA. Coordinates 33.748315°, -84.391109° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":33.748315,"lon":-84.391109,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

490

A Cycle-Based Formulation and Valid Inequalities for DC Power ...  

E-Print Network (OSTI)

Dec 19, 2014 ... Abstract: It is well-known that optimizing network topology by switching on and off transmission lines improves the efficiency of power delivery in...

Burak Kocuk

2014-12-19T23:59:59.000Z

491

Rev. August 2013 Curriculum Vitae  

E-Print Network (OSTI)

-criteria optimization of the parameters of the Nurek-Regar 500-kV power transmission line" · 1972, High School # 29 and AC Overhead Transmission Lines", Member, 2012-present · Steering Committee of the International Performance of Distribution Lines, Member, 1999-present · International Commission on Atmospheric Electricity

Florida, University of

492

Brawley Power Plant Abandoned | Open Energy Information  

Open Energy Info (EERE)

Abandoned Abandoned Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Brawley Power Plant Abandoned Abstract N/A Authors California Division of Oil, Gas and and Geothermal Resources Published Journal Geothermal Hot Line, 1985 DOI Not Provided Check for DOI availability: http://crossref.org Online Internet link for Brawley Power Plant Abandoned Citation California Division of Oil, Gas, and Geothermal Resources. 1985. Brawley Power Plant Abandoned. Geothermal Hot Line. 15(2):76-77. Retrieved from "http://en.openei.org/w/index.php?title=Brawley_Power_Plant_Abandoned&oldid=682727" Categories: References Uncited References Geothermal References What links here Related changes Special pages Printable version Permanent link Browse properties

493

Categorical Exclusion Determinations: Bonneville Power Administration |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 12, 2012 June 12, 2012 CX-008698: Categorical Exclusion Determination Poorman Ponds Property Funding CX(s) Applied: B1.25 Date: 06/12/2012 Location(s): Washington Offices(s): Bonneville Power Administration June 12, 2012 CX-008697: Categorical Exclusion Determination Sale of Line Mile 1 of the 115 Kilovolt (kV) Tanner Tap to Snoqualmie-Lake Tradition #1 Transmission Line CX(s) Applied: B1.24 Date: 06/12/2012 Location(s): Washington Offices(s): Bonneville Power Administration June 12, 2012 CX-008696: Categorical Exclusion Determination Power Circuit Breaker Replacement Project CX(s) Applied: B4.6 Date: 06/12/2012 Location(s): Washington, Oregon, Idaho, Montana, Wyoming Offices(s): Bonneville Power Administration June 5, 2012 CX-008702: Categorical Exclusion Determination Forest Grove-McMinnville #1 Wood Pole Replacement Projects

494

Terahertz Quantum-Cascade Transmission-Line Metamaterials  

E-Print Network (OSTI)

Terahertz Transmission-Line Metamaterials . . . . . . .CRLH Transmission Lines . . . . . . . . . . . . . . . .Terahertz CRLH Transmission-Line Metamaterials . . . . . . .

Tavallaee, Amir Ali

2012-01-01T23:59:59.000Z

495

Preventing Electrical Shock  

E-Print Network (OSTI)

was electrocuted when a hay elevator he was moving contacted a 7,200-volt power line almost 22 feet above the ground. The farmer had often moved the 45-foot hay elevator by himself, manually or by tractor, without mishap. On this occasion, a neighbor and a... the lines buried underground. ? Do not allow children to climb any tree near a power line. Ask your power company for help trimming tree branches that could touch power lines. ? Never attempt to raise or move a power line. Treat all overhead power lines...

Smith, David

2004-09-16T23:59:59.000Z

496

Using a Balun Transformer Combiner for High Power Microwave Experiments  

SciTech Connect

A novel coaxial power combiner design has been duplicated that has distinct advantages over other combiner geometries that can handle high power. This design is being applied to combine four 3 kW power supplies to obtain a 10 kW, 5 MHz system for an ICRF antenna on HSX. In the past, Wilkinson type combiners have had limited application to high power systems because of the lack of non-inductive, high power, 100 Omega balance loads. With this new design, standard 50 Omega dummy loads can be used instead for the balance load. The cost is considerably lower than lumped element combiner designs which are dominated by capacitor costs. At such a relatively low frequency, a 3-dB quarter-wave coupled-line coupler becomes impractically long, and a conventional branch-line hybrid requires 35 Omega-line, which is commercially unavailable. The balun combiner uses less transmission line than a ring hybrid and has good bandwidth characteristics even away from its best line impedance. Theoretical calculations and modeling were performed for line impedances from 65 Omega to 75 Omega. Measurements from a low-power test device show excellent agreement with theory, and construction of the high power system is underway.

Kaufman, Michael C [ORNL; Pesavento, Philip V [ORNL

2011-01-01T23:59:59.000Z

497

New protection method for HVDC lines including cables  

SciTech Connect

For the third project of the Hokkaido-Honshu HVDC Link in Japan, called the HVDC Link III project (rated at 250 kVdc-1,200 A-300 MW), the authors developed an HVDC transmission line protection method based on a new working principle that allows high-speed and highly sensitive detection of faults, enhancing reliability in the supply of electric power. In general, increasing the sensitivity of relays will lead to an increased likelihood of undesired operation whereas lowering the sensitivity will impair the responsiveness of the relays. The proposed method meets these apparently incompatible requirements very well. Basically classified as a differential scheme, the HVDC transmission line protection method compensates for a charging and discharging current that flows through the line-to-ground capacitance at times of voltage variations caused by a line fault or by the operation of dc power systems. The developed protection method is also characterized in that it uses current changes induced by voltage variations to restrain the operation of a relay. This configuration has made the proposed method far superior in responsiveness and sensitivity to the conventional protection method. A simulation using an EMTP (Electro-Magnetic Transients Program) was conducted on this method. Developed relay equipment embodying the new protection method was subjected to various verification tests, where this equipment was connected to a power system simulator, before being delivered to the HVDC Link III facility.

Takeda, H.; Ayakawa, H.; Tsumenaga, N.; Sanpei, M.

1995-10-01T23:59:59.000Z

498

Power transaction issues in deregulated power systems  

E-Print Network (OSTI)

With the introduction of the deregulation in the power industry, it becomes possible to wheel power across the transmission network. Hence, some issues involving the network's physical capability to transfer power and the allocation of the network...

Roycourt, Henrik

2012-06-07T23:59:59.000Z

499

Keeler-to-Tillamook Transmission Line Rebuild Project Draft Environmental Assessment  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Keeler-to-Tillamook Transmission Line Keeler-to-Tillamook Transmission Line Rebuild Project Draft Environmental Assessment October 2013 This page deliberately left blank. Bonneville Power Administration i Contents Chapter 1 Purpose and Need for Action ............................................................................................ 1-1 1.1 Introduction ................................................................................................................................. 1-1 1.2 Need for Action ............................................................................................................................ 1-1 1.3 Purposes of Action ....................................................................................................................... 1-2

500

High Precision Load Current Sensing using On-Line Calibration of Trace Resistance  

E-Print Network (OSTI)

-line specification. This and high-bandwidth measurement of the load current in the allows the converter to follow pose unprecedented demands on DC-DC power converters, it could be very difficult to follow the loadHigh Precision Load Current Sensing using On-Line Calibration of Trace Resistance in VRM

Sanders, Seth