Powered by Deep Web Technologies
Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Overhead Line Worker Practices Survey: 2012  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) has undertaken a multiyear research project to identify and describe leading industry overhead line worker practices. This effort is intended to identify and document industry overhead distribution line work practices of note, identify shortterm products (such as practices guidelines) that EPRI can ...

2012-08-23T23:59:59.000Z

2

IPF Overhead Line Uprating Wizard  

Science Conference Proceedings (OSTI)

The Increased Power Flow (IPF) Wizard ranks various line uprating methods available on the basis of a series of relatively simple questions about the rating increase needed, the condition of the line, regulatory restrictions, and basic design parameters of the existing line. The Wizard’s knowledge base contains 17 different uprating methods selected and defined by the contractors. A series of 22 questions concerning such variables as line rating assumptions, physical condition, and permitting were define...

2009-03-17T23:59:59.000Z

3

HVDC Overhead Line Performance Study  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) is documenting the various factors that should be considered when designing and building new high-voltage direct current (HVDC) lines or when converting AC lines to HVDC. Given the limited number of HVDC lines that have been designed and built around the world, even some basic factors (for example, insulator flashover in severely contaminated regions) are not completely understood. This report concerns a crucial first step in better understanding and improving...

2011-08-02T23:59:59.000Z

4

Overhead Transmission Line Inspector Workshop Proceedings - 2012  

Science Conference Proceedings (OSTI)

 This report presents the proceedings of the Electric Power Research Institute (EPRI) Overhead Transmission Line Inspector Workshop, which was held Monday, July 30, through Wednesday, August 1, 2012, at the Hyatt Place Hotel and at Georgia Power’s Klondike Training Center in Lithonia, Georgia.The first half day of the workshop focused on inspection and assessment, with a participant roundtable discussion, followed by utility, vendor and EPRI presentations on the ...

2012-11-14T23:59:59.000Z

5

Bimetallic steel/aluminum wire for overhead telecommunication lines  

Science Conference Proceedings (OSTI)

for power transmission and overhead telecommunication lines and other .... " Method of manufacture of bimetallic wire for, e.g., trolley-bus cable or rods, n Inven-.

6

Emerging and Future Inspection of Overhead Transmission Lines  

Science Conference Proceedings (OSTI)

This technical update report describes research by the Electric Power Research Institute (EPRI) into emerging and future overhead electric transmission line inspection and assessment technologies. In 2008, EPRI published a report entitled Future Inspection of Overhead Transmission Lines (product 1016921) that documented scenarios and viable technologies that could be applied for the inspection of transmission lines over a multi-decade timeframe. That document was intended to provide a roadmap for near- a...

2011-12-22T23:59:59.000Z

7

Guide for Selection of Overhead Line Components and Design Parameters  

Science Conference Proceedings (OSTI)

This report outlines the contents for the Electric Power Research Institute (EPRI) report Guide for Selection of Overhead Line Components and Design Parameters that is to be developed under the Design and Construction—Approach and Practice project. It identifies the topics to be covered and the scope to be developed for each topic. New topics will be added to the list whenever such needs arise. Detailed information suitable for use in the design of overhead lines on a few topics will be ...

2012-12-31T23:59:59.000Z

8

Nondestructive Testing of Overhead Transmission Lines: Numerical and Experimental Investigation  

E-Print Network (OSTI)

Overhead transmission lines are periodically inspected using both on-ground and helicopter-aided visual inspection. Factors including sun glare, cloud cover, close proximity to power lines and the rapidly changing visual circumstances make airborne inspection of power lines a particularly hazardous task. In this research, a finite element model is developed that can be used to create the theoretical dispersion curves of an overhead transmission line. The complex geometry of the overhead transmission line is the primary reason for absence of a theoretical solution to get the analytical dispersion curves. The numerical results are then verified with experimental tests using a non-contact and broadband laser detection technique. The methodology developed in this study can be further extended to a continuous monitoring system and be applied to other cable monitoring applications, such as bridge cable monitoring, which would otherwise put human inspectors at risk.

Kulkarni, Salil Subhash

2009-12-01T23:59:59.000Z

9

Overhead Transmission Line Lightning and Grounding Reference Book 2012  

Science Conference Proceedings (OSTI)

In North America and many other parts of the world, lightning remains the primary cause of transmission line outages, momentary interruptions, and reliability and maintenance problems. The lightning performance of transmission lines may be improved by applying overhead ground wires, providing a low impedance connection to ground, and selecting appropriate insulation levels for the phase conductors. The success of these measures is not always ...

2012-12-12T23:59:59.000Z

10

Overhead Line Loading Program (OHLOAD) Version 2.0  

Science Conference Proceedings (OSTI)

OHLOAD allows the user to calculate thermal ratings and conductor temperatures for overhead power transmission lines. EPRI's Overhead Line Loading Program (OHLOAD 2.0) calculates bare conductor temperatures and thermal ratings based on user-specified weather parameters and user-specified electrical load. The calculation methods available in OHLOAD are based on various CIGRE, IEEE, and EPRI documents. WindowsXP, Vista, and Windows 7. The PC must have at least 20 MB of free disk space and a Pentium II proc...

2012-05-01T23:59:59.000Z

11

Future Inspection of Overhead Transmission Lines  

Science Conference Proceedings (OSTI)

This report documents scenarios and technologies that can be applied in the future for the inspection of transmission lines. Scenarios describe the utilization of a range of concepts, including distributed sensors, unmanned airborne vehicles, RF communication, and robotics. An approach to performing demonstration projects using currently available technologies is provided and will be implemented in the following phases of the project.

2008-06-23T23:59:59.000Z

12

HVDC Overhead Line Design Guide: 2013 Interim Report  

Science Conference Proceedings (OSTI)

This report is an updated version of the Electric Power Research Institute (EPRI) report HVDC Overhead Line Design Guide (1024326). An outline developed in 2012 identified all of the topics to be covered by the report. A draft for high-voltage, direct-current (HVDC) ground electrodes and another for HVDC conductor selection were also included in the 2012 version. These topics were finalized in 2013, and the topics of HVDC line performance and insulation were added to the report. All four ...

2013-12-23T23:59:59.000Z

13

Thermal Models of Overhead Transmission Lines Operating at High Temperatures  

Science Conference Proceedings (OSTI)

Bare stranded overhead transmission line conductorsreferred to as aluminum conductor steel reinforced ACSRtypically consist of at least two layers of aluminum strands, helically stranded around a core consisting of steel wires. The current that flows through such conductors is located predominantly in the aluminum layers while the steel core provides mechanical strength and limits sag at high temperature. The lack of new line construction combined with the decoupling of transmission from power generatio...

2010-12-23T23:59:59.000Z

14

Guide for High Temperature Operation of Overhead Lines: 2012 Updates  

Science Conference Proceedings (OSTI)

This Guide assists users in raising the capacities of overhead transmission lines by increasing the conductor temperature. It is based on a wealth of knowledge accumulated from extensive research conducted internally at the Electric Power Research Institute (EPRI), information from manufacturers, and results from research conducted outside of EPRI. The Guide has evolved from a collection of numerous EPRI reports published in the past, including Effect of High-Temperature Cycling on Conductor ...

2012-12-12T23:59:59.000Z

15

Guide for Operating Overhead Lines at High Temperatures  

Science Conference Proceedings (OSTI)

This Guide assists users in raising the capacities of overhead transmission lines by increasing the conductor temperature. It is based on a wealth of knowledge accumulated from extensive research conducted internally at the Electric Power Research Institute (EPRI), information from manufacturers, and results from research conducted outside of EPRI. The Guide evolved from a collection of numerous EPRI reports published in the past, for example, Effect of High-Temperature Cycling on Conductor Systems (EPRI...

2010-12-13T23:59:59.000Z

16

Overhead Transmission Line Inspection - Online Training (OTLOT) Version 9.0  

Science Conference Proceedings (OSTI)

The EPRI Overhead Transmission Line Inspection - Online Training is a CD-based application for training on how to complete overhead transmission line inspections.It contains fourteen modules of instruction on overhead transmission line inspections. A browser interface helps the user navigate through the interactive training. As the user moves through the module, it provides instruction, application practice, and review questions.Benefits & ...

2013-12-16T23:59:59.000Z

17

PRE-SW EPRI Overhead Transmission Line Inspection - Online Training (OTLOT) Version 9.0, Beta  

Science Conference Proceedings (OSTI)

The EPRI Overhead Transmission Line Inspection - Online Training is a CD-based application for training on how to complete overhead transmission line inspections.It contains fourteen modules of instruction on overhead transmission line inspections. A browser interface helps the user navigate through the interactive training. As the user moves through the module, it provides instruction, application practice, and review questions.    Benefits ...

2013-08-25T23:59:59.000Z

18

Life-Cycle Cost Analysis Overhead Transmission Lines (LCCA) Version 1.1  

Science Conference Proceedings (OSTI)

The LCCA software is a tool to assist transmission line designers in selecting the optimized design for an overhead line by comparing the life-cycle cost of various design options. Windows2000, XP, and Vista Excel 2003 and 2007

2011-12-15T23:59:59.000Z

19

Assessment of Environmental Effects of Current Underground and Overhead Transmission Line Construction and Maintenance in the United States  

Science Conference Proceedings (OSTI)

This report assesses environmental effects of current underground and overhead transmission line construction and maintenance in the United States.

2008-12-18T23:59:59.000Z

20

Live Working Considerations in Design and Construction of Overhead Transmission Lines  

Science Conference Proceedings (OSTI)

Live working (LW) on overhead transmission lines is the performance of maintenance, construction, and inspection of equipment and circuits that are energized or that may become energized. This report discusses aspects of design and construction of overhead transmission lines that are important to (LW) and examines design modifications that can significantly impact the safe, efficient, and cost-effective performance of LW. This guidance should help line designers identify ways to incorporate the ...

2013-12-02T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Dynamic Simulation of Lightning Attachment to Earthed Overhead Transmission Line Structures  

Science Conference Proceedings (OSTI)

In this paper a novel method is presented to investigate lightning stroke attachment to earthed overhead transmission line structures. This method is based on the dynamic simulation of lightning downward leader movement toward the ground in three dimensions. ... Keywords: charge simulation method, downward leader, lightning, transmission line, upward leader

Mohammad Reza Bank Tavakoli; Behrooz Vahidi

2010-07-01T23:59:59.000Z

22

EPRI-GTC Overhead Electric Transmission Line Siting Methodology  

Science Conference Proceedings (OSTI)

This report explains and documents a standardized process that utilities could use to improve the way transmission line routes are evaluated and selected.

2006-02-06T23:59:59.000Z

23

Proceedings of the Inspection and Assessment of Overhead Transmission Line Equipment Workshop: 13 – 15 May 2003, Monterey, CA  

Science Conference Proceedings (OSTI)

This report contains papers and materials presented at the Inspection and Assessment of Overhead Transmission Line Equipment Workshop held in Monterey, California in May of 2003.

2003-12-15T23:59:59.000Z

24

Interaction Between AM Radio Broadcast Antennas and Overhead Power Lines  

Science Conference Proceedings (OSTI)

Metallic structures, power lines or otherwise, can affect the operation of AM radio broadcast station antennas if the dimensions of those structures are related to the wavelength of the radio signal at the station's operating frequency. For power lines, the dimensions of interest can be either the height of the support structures themselves or the length of a loop formed by adjacent structures, the shield wires connecting them, and the return path in the earth. When resonance occurs between the power lin...

2012-05-10T23:59:59.000Z

25

Evaluation of Instrumentation and Dynamic Thermal Ratings for Overhead Lines  

Science Conference Proceedings (OSTI)

In 2010, a project was initiated through a partnership between the Department of Energy (DOE) and the New York Power Authority (NYPA) to evaluate EPRI?s rating technology and instrumentation that can be used to monitor the thermal states of transmission lines and provide the required real-time data for real-time rating calculations. The project included the installation and maintenance of various instruments at three 230 kV line sites in northern New York. The instruments were monitored, and data collection and rating calculations were performed for about a three year period.

Phillips, A.

2013-01-31T23:59:59.000Z

26

EPRI Overhead Transmission Line Inspection - Online Training (OTLOT) Version 8.0  

Science Conference Proceedings (OSTI)

This course describes the different types of compression connectors for overhead transmission lines and their application, construction, degradation and failure modes, inspection and assessment methods, and remediation techniques.    Benefits & Value:Proper Construction and Installation of Compression Connectors will allow for the following:Self-paced learning opportunityReduced cost of travel and time outside the ...

2012-11-13T23:59:59.000Z

27

Thermal and Corona Models of Overhead Transmission Lines Operating at High Temperatures  

Science Conference Proceedings (OSTI)

In an attempt to meet increasing demand by pushing more power through existing lines, the power industry has frequently resorted to operating overhead transmission lines at higher temperatures than ever before. There is reason to believe that the empirical models developed in the past for determining conductor temperature and corona performance are in error at these elevated temperatures. In an effort to safely and reliably push more power, it will be important for utilities to understand the temperature...

2007-12-11T23:59:59.000Z

28

Electrical and mechanical design criteria for EHV and UHV: overhead transmission lines  

Science Conference Proceedings (OSTI)

The results are presented of a program devoted to the selection of electrical and mechanical design criteria and parameters for overhead power transmission lines for ac systems rated at from 345 to 1100 kV and for dc systems rated at from 600 to 1200 kV. Information is included on the environmental effects, i.e., audible noise and electric fields, of the lines, mechanical and economic requirements, safety, failures, grounding, and lightning protection. (LCL)

Not Available

1980-06-01T23:59:59.000Z

29

Survey of Utility Practices for Rating Overhead Transmission Line and Component Condition: Survey Results  

Science Conference Proceedings (OSTI)

Utilities have expressed an interest in using analytical tools and methods for evaluating the condition of their overhead transmission facilities and line components. These analytical techniques are intended to provide a systematic approach to ensure that planned expenditures for inspection and maintenance programs are being applied in the most cost-effective way that benefits the organization and public as a whole. Prescriptive or time-based methods used by the utilities for many years might not be ...

2013-12-22T23:59:59.000Z

30

Proceedings of the First Overhead Transmission Line Equipment and Maintenance Practices Conference: 14-16 May 2002, Monterey, CA  

Science Conference Proceedings (OSTI)

This report contains the presentation material and papers from the 1st Overhead Transmission Line Equipment and Maintenance Practices Conference held in Monterey, California, May 14-16, 2002.

2002-07-29T23:59:59.000Z

31

Inspection and Assessment of Overhead Transmission Line Hardware, Conductors and Shield Wires: Technology Overview of Conductor Inspection Tools  

Science Conference Proceedings (OSTI)

This report summarizes in detail the theory and operation of technologies for the inspection of overhead transmission line conductors and evaluates their effectiveness. It covers existing technologies and technologies that are commercially available but have the promise of becoming effective screening and, in some cases, predictive tools in the future. Technologies described and assessed include:The Cormon overhead line corrosion detectorThe Cross-Checker ...

2013-12-22T23:59:59.000Z

32

The Reliability Investigation on ACSR Splice Connector Systems Used in Overhead Power transmission Lines  

SciTech Connect

Due to material discontinuity and inherited forming mechanism from a crimped-type splice connector, the associated conductor-connector system is highly sensitive to system components aging, especially during high-temperature operations. Furthermore, due to the increase in power demand and limited investment in new infrastructure, existing overhead power transmission lines often need to operate at temperatures higher than the original designed values. This has led to the accelerated aging and degradation of conductor-connector systems. The implications of connector aging are two-fold: (1) significant increase in resistivity of the splice connector and (2) significant reduction in the connector clamping strength. Therefore, splice connectors are one of the weakest links in the electric power transmission infrastructure. In this paper we will discuss the reliability of splice connector systems, including both single stage and two stage splice connectors, used in ACSR conductor of transmission lines under high temperature operations.

Wang, Jy-An John [ORNL; Jiang, Hao [ORNL; Ren, Fei [ORNL

2012-01-01T23:59:59.000Z

33

Optimizing the replacement of overhead lines in rural distribution systems with respect to reliability and customer value  

E-Print Network (OSTI)

In this paper we present a method for establishing the value of a network’s components from a reliability worth perspective. The method can be applied to a general distribution system i.e. both for radial and meshed network systems. Moreover, this paper shows results from an application study for a rural network system that is dominated by overhead lines. The purpose of the study was to establish the value of a secondary feeding point. Further, the method is used to establish the best replacement strategy for the concerned overhead lines.

Patrik Hilber; Bengt Hällgren; Lina Bertling

2005-01-01T23:59:59.000Z

34

Distribution Library--Wood Poles  

Science Conference Proceedings (OSTI)

EPRI has sponsored research and published information on a wide variety of topics related to wood poles for overhead lines. Many of these resources, particularly older publications, are difficult for EPRI members to find and use. To help ensure retention of this valuable knowledge base, EPRI sponsored the project reported herein to capture this information and make it accessible in an easy-to-use electronic media (E-Media) repository.

2005-12-22T23:59:59.000Z

35

Mutual Design Considerations for Overhead AC Transmission Lines and Gas Transmission Pipelines, Volume 1: Engineering Analysis  

Science Conference Proceedings (OSTI)

This reference book presents data on an investigation into the mutual effects of electric power transmission lines and natural gas transmission pipelines sharing rights-of-way. Information is useful to both power and pipeline industry users.

1978-09-01T23:59:59.000Z

36

Proposed Norton-Tesuque 115 kV overhead transmission line and substation in Sante Fe, New Mexico  

SciTech Connect

Construction is proposed of a 115/12.5-kilovolt (kV), 10/12.5-megavolt-ampere (MVA) substation in the Tesuque area and of 9.02 miles of 115-kV overhead transmission line from the Norton Station to the new substation in an area approximately three miles north of Sante Fe, New Mexico. The project would involve the granting of a 100-foot width right-of-way by the Tesuque Pueblo, the construction of the substation on the Tesuque Pueblo Indian Reservation between the Rio Tesuque and New Mexico 85, the addition of a 115-kV breaker bay at Norton Station, and the installation of two underground 12.47-kV distribution feeders to connect to existing ones in the Tesuque area. In addition, the station would be designed to accommodate one future underground 12.47-kV feeder that would terminate at a future distribution line in the Tesuque area. The preferred transmission line route would originate at the Norton Station and proceed east-northeast up Calabasa Arroyo to a point approximately 1.1 miles north of the southwest corner of the Tesuque Pueblo boundary. From this point the route would proceed east to the proposed substation site.

1985-06-01T23:59:59.000Z

37

Field Guide: Construction and Inspection of Compression Connectors for Overhead Transmission Lines  

Science Conference Proceedings (OSTI)

This field guide provides a general, field-deployable resource for utility professionals who are engaged in the construction and installation of compression connectors, as well as those who are involved with in-service inspection and assessment of this line component. It describes typical applications, compression connector basics, construction methods, common assembly errors, and inspection methods. In addition, it provides a list of relevant technical and training resources.The ...

2013-08-15T23:59:59.000Z

38

Thermal and Corona Models of Overhead Transmission Lines Operating at High Temperatures  

Science Conference Proceedings (OSTI)

In order to provide electric power to a society that is continuously increasing its power consumption, without having to sustain huge capital expenditures for new infrastructure, the power industry is pushing more power through existing lines. Although this results in conductors operating at higher temperatures, which in turn results in higher thermal and mechanical losses, the industry is finding it to be a cost-effective approach when compared to alternatives. The demand for electric power over transmi...

2008-12-23T23:59:59.000Z

39

Overhead electric power transmission line jumpering system for bundles of five or more subconductors  

DOE Patents (OSTI)

Jumpering of electric power transmission lines at a dead end tower. Two transmission line conductor bundles each contain five or more spaced apart subconductors (5) arranged in the shape of a cylinder having a circular cross section. The ends of each bundle of subconductors are attached with insulators to a dead end tower (1). Jumpering allows the electric current to flow between the two bundles of subconductors using jumper buses, internal jumper conductors, and external jumper conductors. One or more current collecting jumper buses (37) are located inside each bundle of subconductors with each jumper bus being attached to the end of a subconductor. Small-diameter internal jumper conductors (33) are located in the inherently electrically shielded area inside each bundle of subconductors with each subconductor (except ones having an attached jumper bus) having one internal jumper conductor connected between that subconductor's end and a jumper bus. Large-diameter external jumper conductors (9) are located outside each bundle of subconductors with one or more external jumper conductors being connected between the jumper buses in one bundle of subconductors and the jumper buses in the other bundle.

Winkelman, Paul F. (Beaverton, OR)

1982-01-01T23:59:59.000Z

40

HVDC Overhead Transmission Guide  

Science Conference Proceedings (OSTI)

This report is the initial version of a new EPRI publication, the HVDC Overhead Line Design Guide. The main objective of the report is to present a proposed outline for the guide so that users can review and discuss the content. The outline will then be fine-tuned with users to meet their needs. Topics unique to high-voltage direct current (HVDC) systems have been identified and included in the outline. The topics will be addressed and design information added each year. The ultimate goal ...

2012-12-12T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Magnetic field exposure assessment for adult residents of Maine who live near and far away from overhead transmission lines  

Science Conference Proceedings (OSTI)

Sixty-Hz magnetic field exposures were measured for 45 adult residents of Maine. Thirty of the subjects resided near rights-of-way (ROWs) with either 345- and 115-kV transmission lines, or ROWs with only 115-kV transmission lines; fifteen resided far from any transmission lines. Personal exposure data for a single 24-hour period was acquired with the EMDEX. The EMDEX's event-marker button was used to partition exposures into Home and Away components. Also, three area measurements were taken for each subject during the personal exposure measurement period: (1) 24-hr fixed-site bedroom measurement with a second EMDEX; (2) Spot measurements in at least three rooms of every residence; and (3) Spot measurements outside each residence. Residence near transmission lines highly loaded during the measurement period was associated with increased Home and Total exposure relative to a far-away population. Average exposure level while away from home was uniform (at about 2 mG) throughout the study population. On a quantitative level, Home exposure was correlated equivalently with Spot-In (r = .70) and the 24-hr fixed site measurement (r = .68). Correlations of area measurements with Total exposure were weaker because of the dilution effect of Away exposure (r = .64 for Spot-In; r = .61 for 24-h Bedroom). Away and Home exposures were not correlated (r = .14), which reinforced our confidence that the participants used the EMDEX correctly. The data suggest the need for caution before inferences are drawn about total personal exposure from area measurements. The study demonstrates the feasibility of obtaining valid measures of magnetic-field exposure with the personal exposure monitors that have been developed.

Kavet, R.; Silva, J.M.; Thornton, D. (Enertech Consultants, Campbell, CA (United States))

1992-01-01T23:59:59.000Z

42

Overhead Lineworker Practices: Lincoln Electric System  

Science Conference Proceedings (OSTI)

This report describes the findings of an overhead distribution line worker practices immersion conducted by the Electric Power Research Institute (EPRI) with the Lincoln Electric System (LES). The immersion was conducted as part of a multiyear effort by EPRI to identify noteworthy line worker practices related to the management of overhead distribution systems. More specifically, this report profiles the practices (the people, processes, and technology) in place at LES, a Lincoln, Nebraskabased utility. ...

2011-12-21T23:59:59.000Z

43

SMB Host Processor Overhead  

NLE Websites -- All DOE Office Websites (Extended Search)

SMB SMB SMB Description There are two benchmarks included here. The msg_rate test measures the sustained MPI message rate using a communication pattern found in many real applications. For a complete explanation of the routine refer to http://www.cs.sandia.gov/smb/msgrate.html. The mpi_overhead test uses a post-work-wait method using MPI non-blocking send and receive calls to measure the user level overhead of the respective MPI calls. For a complete explanation of the routine refer to http://www.cs.sandia.gov/smb/overhead.html. Download SMB tar file How to Build The source files are in the src directory, in smb_1.0-1/src/mpi_overhead and smb_1.0-1/src/msgrate. Edit the Makefile for your environment and type 'make.' How to Run The executables run a single message at a time. The "run_script" scripts

44

Measurements of a crenelated iron pole tip for the VLHC transmission line magnet  

E-Print Network (OSTI)

The Very Large Hadron Collider (VLHC) is under conceptual design in Fermilab. One option under development is a 2-Tesla warm iron 2-in-1 single turn superferric magnet built around an 80 kA superconducting transmission line. A normal-conducting test stand was built to optimize the iron lamination shape for this magnet. It uses a water- cooled copper winding to provide the 100 kA-turns needed to generate 2 Tesla fields in both 20 mm air gaps of the magnet. A magnetic measurement facility has been set up for magnetic field mapping, which includes a flat measurement coil, precision stage for coil motion and integrator. Results from a first test of the "crenelation" technique to mitigate the saturation sextupole in iron magnets are described and future plans are discussed. (5 refs).

Di Marco, J; Kashikhin, V V; Makarov, A A; Schlabach, P; MacKay, W W

1999-01-01T23:59:59.000Z

45

Method for decreasing arbitration overhead  

SciTech Connect

This invention is a method for decreasing the arbitration overhead required to transfer messages on a shared multiprocessor bus.

Bergey, A.L. Jr.; Coale, J.L.

1983-12-01T23:59:59.000Z

46

Overhead Distribution Vegetation Challenges  

Science Conference Proceedings (OSTI)

It is not uncommon for overhead distribution conductors to make contact with trees. While these incidental contacts can be either intermittent or relatively persistent, they are typically not detectable by overcurrent protection systems and do not result in interruptions on distribution circuits. This report focuses on the levels of fault currents and voltage gradients found along the fault pathway provided by trees from point of contact to earth. The purpose of this investigation was to measure the volt...

2008-12-18T23:59:59.000Z

47

Guide for Transmission Line Grounding  

Science Conference Proceedings (OSTI)

Electrical utilities have a duty to provide effective grounding for managing steady-state and fault currents, whether near a large generating station or at a remote distribution pole ground. For transmission lines, this imperative is usually met with investment in overhead ground wires and grounding electrodes. Effective grounding at each tower improves reliability8212by providing low path impedance to lightning strokes8212and contributes to safety. However, the fundamental physical parameters in ground ...

2007-12-20T23:59:59.000Z

48

Definition: Transmission Line | Open Energy Information  

Open Energy Info (EERE)

Line Line (Redirected from Definition:Transmission lines) Jump to: navigation, search Dictionary.png Transmission Line A system of structures, wires, insulators and associated hardware that carry electric energy from one point to another in an electric power system. Lines are operated at relatively high voltages varying from 69 kV up to 765 kV, and are capable of transmitting large quantities of electricity over long distances.[1] View on Wikipedia Wikipedia Definition An overhead power line, also known as a "pylon" in some areas, is a structure used in electric power transmission and distribution to transmit electrical energy along large distances. It consists of one or more conductors (most often three or four) suspended by towers or utility poles. Since most of the insulation is provided by air, overhead power lines are

49

Overhead Transmission Inspection and Assessment Guidelines -- 2011  

Science Conference Proceedings (OSTI)

The emphasis within the transmission arena has shifted from designing and building new transmission facilities to optimizing the use, performance, and life of existing facilities. In the early 1990s, EPRI established an initiative to examine the capabilities and limitations of existing inspection and assessment methods and technology. One of the key needs identified was information on methods and technologies for inspecting/assessing the conditions and life expectancy of overhead transmission line compon...

2011-12-23T23:59:59.000Z

50

Overhead Transmission Inspection and Assessment Guidelines - 2012  

Science Conference Proceedings (OSTI)

The emphasis within the transmission arena has shifted from designing and building new transmission facilities to optimizing the use, performance, and life of existing facilities. In the early 1990s, EPRI established an initiative to examine the capabilities and limitations of existing inspection and assessment methods and technology. One of the key needs identified was information on methods and technologies for inspecting/assessing the conditions and life expectancy of overhead transmission line ...

2012-12-20T23:59:59.000Z

51

Sizing of Overhead Ground Wires for Lightning  

Science Conference Proceedings (OSTI)

Overhead ground wires, or shield wires, are placed on transmission lines as air terminals for lightning strikes to shield the phase conductors from direct strikes. Although of short duration, lightning strikes to ground wires may result in significant damage. Utilities are increasingly using optical fiber ground wires (OPGWs), and severe damage to the OPGWs could result in failure of the communication link. There is renewed interest in the dimensioning and testing of ground wires for improved ...

2012-12-12T23:59:59.000Z

52

Mutual Design Considerations for Overhead AC Transmission Lines and Gas Transmission Pipelines: Volume 1: Engineering Analysis; Volu me 2: Prediction and Mitigation Procedures  

Science Conference Proceedings (OSTI)

This joint-effort project between Pipeline Research Committee of the A.G.A. and EPRI was initiated to develop analytical techniques for determining the induced potential on pipelines that parallel electric transmission lines. Its purpose was to develop analytical methods for prediction and mitigation of voltages induced on pipelines by nearby ac transmission lines. Required analytical techniques were developed and supported by field test results. New mitigation methods were developed and old ones evaluat...

1978-10-01T23:59:59.000Z

53

Definition: Transmission Line | Open Energy Information  

Open Energy Info (EERE)

Transmission Line Transmission Line Jump to: navigation, search Dictionary.png Transmission Line A system of structures, wires, insulators and associated hardware that carry electric energy from one point to another in an electric power system. Lines are operated at relatively high voltages varying from 69 kV up to 765 kV, and are capable of transmitting large quantities of electricity over long distances.[1] View on Wikipedia Wikipedia Definition An overhead power line, also known as a "pylon" in some areas, is a structure used in electric power transmission and distribution to transmit electrical energy along large distances. It consists of one or more conductors (most often three or four) suspended by towers or utility poles. Since most of the insulation is provided by air, overhead power lines are

54

Application Guide for Determining Maximum Switching Transient Overvoltages of Overhead Lines Rated 100 kV and Above Using the Electr omagnetic Transients Program (EMTP)  

Science Conference Proceedings (OSTI)

In recent years, through attrition and in other ways, utilities have lost many of the engineers that once performed time-domain (transient) simulations of their power systems. As a result, using the electromagnetic transients program (EMTP) to perform time-domain simulations of the power system has become a lost art; and, as a consequence, such tasks as being able to easily determine the maximum transient overvoltage for a particular transmission line have become arduous for some utilities. At the same t...

2011-11-30T23:59:59.000Z

55

Categorical Exclusion for Wood Pole  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Wood Pole Wood Pole Replacement at two structures (11/6 & 11/9) located along the Oracle-Tucson 115-kV Transmission Line, in Oro Valley, Pima County, Arizona. RECORD OF CATEGORICAL EXCLUSION DETERMINATION A. Proposed Action: Western plans to replace deteriorated wood poles, cross arms and X-braces at two existing H-frame structures (11/6 & 1119) located along the Oracle Tucson 115-kV Transmission Line in Pima, Arizona (Figure 1). Built in 1943, its aging components are beyond repair and require replacement. These poles performed poorly during structural tests, and we consider them unstable. This replacement project will ensure the safety of Western's workers and the public as well as reliability of the bulk electric system. Western will accomplish the work by clearing vegetation and blading a level pad at

56

Transport Devices for Overhead Conductors: State of the Art Review and Promising Technologies  

Science Conference Proceedings (OSTI)

This report summarizes activities surrounding the possible development of a transmission line inspection robot as a transport device for overhead conductors. EPRI research on technologies for inspection of transmission line conductors had identified the need for a highly automated transport device to apply available inspection technologies along the length of a transmission line with minimal human intervention. A literature search was performed to identify past robotics work applied to overhead power lin...

2003-12-11T23:59:59.000Z

57

Radial Temperature Gradients of Overhead Conductors: Impact on Sag and Rating Calculations  

Science Conference Proceedings (OSTI)

It is critical for power companies to have a good understanding of the temperatures at which the bare phase conductors in their overhead transmission lines operate, particularly during system emergencies. Overhead lines are designed to have adequate clearance and normal aging for a maximum allowable conductor temperature (MACT). At or near the MACT, the electrical clearances to people, objects, buildings, and other lower-voltage conductors are at their minimum, and the design limit on loss of ...

2012-12-12T23:59:59.000Z

58

Parameters that Influence the Aging and Degradation of Overhead Conductors  

Science Conference Proceedings (OSTI)

EPRI has been investigating degradation mechanisms, inspection methods, and condition assessment methods for overhead line conductors for a few years. This report identifies conductor failure modes and discusses the associated degradation mechanisms. It further discusses methods of inspection and assessment that may be used to establish the current condition of conductors. Finally, it discusses how this data can be used to develop end-of-life criteria and estimate remaining useful life for conductors.

2003-12-22T23:59:59.000Z

59

Big George to Carter Mountain 115-kV transmission line project, Park and Hot Springs Counties, Wyoming. Environmental Assessment  

SciTech Connect

The Western Area Power Administration (Western) is proposing to rebuild, operate, and maintain a 115-kilovolt (kV) transmission line between the Big George and Carter Mountain Substations in northwest Wyoming (Park and Hot Springs Counties). This environmental assessment (EA) was prepared in compliance with the National Environmental Policy Act (NEPA) and the regulations of the Council on Environmental Quality (CEQ) and the Department of Energy (DOE). The existing Big George to Carter Mountain 69-kV transmission line was constructed in 1941 by the US Department of Interior, Bureau of Reclamation, with 1/0 copper conductor on wood-pole H-frame structures without an overhead ground wire. The line should be replaced because of the deteriorated condition of the wood-pole H-frame structures. Because the line lacks an overhead ground wire, it is subject to numerous outages caused by lightning. The line will be 54 years old in 1995, which is the target date for line replacement. The normal service life of a wood-pole line is 45 years. Under the No Action Alternative, no new transmission lines would be built in the project area. The existing 69-kV transmission line would continue to operate with routine maintenance, with no provisions made for replacement.

1994-02-01T23:59:59.000Z

60

Magnet pole tips  

DOE Patents (OSTI)

An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

Thorn, Craig E. (Wading River, NY); Chasman, Chellis (Setauket, NY); Baltz, Anthony J. (Coram, NY)

1984-04-24T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Magnet pole tips  

DOE Patents (OSTI)

An improved magnet more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

Thorn, C.E.; Chasman, C.; Baltz, A.J.

1981-11-19T23:59:59.000Z

62

Treated Wood Pole Management  

Science Conference Proceedings (OSTI)

This document characterizes similarities and differences in international wood pole and wood pole preservative management. The research team identified practices for selection, regulation, and disposition of utility poles outside the United States. Most information is based on interviews and website and published literature searches. Additional research will clarify regulatory positions in other countries and generate improved understanding, which will support strategic planning for U.S. utilities. Utili...

2008-10-29T23:59:59.000Z

63

Path specialization: reducing phased execution overheads  

Science Conference Proceedings (OSTI)

As garbage collected languages become widely used, the quest for reducing collection overheads becomes essential. In this paper, we propose a compiler optimization called path specialization that shrinks the cost of memory barriers for a wide ... Keywords: c#, garbage collection, memory management, read barriers, write barriers

Filip Pizlo; Erez Petrank; Bjarne Steensgaard

2008-06-01T23:59:59.000Z

64

Reducing memory sharing overheads in distributed JVMs  

Science Conference Proceedings (OSTI)

Distributed JVM systems by supporting Java’s shared-memory model enable concurrent Java applications to run transparently on clusters of computers. Aiming to reduce the overheads associated to memory coherence enforcement mechanisms required in ... Keywords: JVM, Java, cluster computing, concurrent Java applications, distributed shared memory, high-performance computing

Marcelo Lobosco; Orlando Loques; Claudio L. de Amorim

2005-09-01T23:59:59.000Z

65

Optimal Design of Overhead Distribution Systems  

Science Conference Proceedings (OSTI)

It is not uncommon for overhead distribution conductors to make contact with trees. These incidental contacts can be either intermittent or relatively persistent, are typically not detectable by overcurrent protection systems, and typically do not result in interruptions on distributions circuits. This project focuses on assessing voltage gradients and fault currents created when trees come into contact with distribution conductors, allowing current to flow through the tree from point of contact to earth...

2007-12-19T23:59:59.000Z

66

Summit-Watertown transmission line project, South Dakota. Final Environmental Assessment  

SciTech Connect

The Western Area Power Administration (Western) needs to rebuild the existing Summit-Watertown 115-kV transmission line, located in northeastern South Dakota, and western Minnesota. Nearly 60 percent of the existing facility was replaced in 1965 after severe ice-loading broke structures and wires. Because of the extensive loss of the line, surplus poles had to be used to replace the damaged H-frame structures. These were of varying sizes, causing improper structure loading. Additionally, the conductors and overhead shield wires have been spliced in numerous places. This provides additional space on these wires for icing and wind resistance, which in turn create problems for reliability. Finally, a progressive fungal condition has weakened the poles and, along with the improper loading, has created an unsafe condition for maintenance personnel and the general public.

1993-12-01T23:59:59.000Z

67

Demonstration of Advanced Conductors for Overhead Transmission Lines  

Science Conference Proceedings (OSTI)

This report describes a collaborative research project to evaluate the operational performance of advanced High-Temperature, Low-Sag (HTLS) conductors through approximately three years of field experience. The results of the project provide general information on installing, sagging, and clipping HTLS conductors and about their long-term behavior at different electrical current levels and in various geographical locales. Key information is provided on design, installation, operation, and maintenance of s...

2008-07-29T23:59:59.000Z

68

The Adiabatic Pole-to-Pole Overturning Circulation  

Science Conference Proceedings (OSTI)

The adiabatic pole-to-pole cell of the residual overturning circulation (ROC) is studied in a two-hemisphere, semienclosed basin, with a zonally reentrant channel occupying the southernmost eighth of the domain. Three different models of ...

Christopher L. Wolfe; Paola Cessi

2011-09-01T23:59:59.000Z

69

Single phase two pole/six pole motor  

DOE Patents (OSTI)

A single phase alternating current two pole/six pole motor is provided with a main stator winding having six coils disposed unequally around the periphery of the machine. These coils are divided into two groups. When these groups are connected such that their magnetomotive forces are additive, two pole motor operation results. When the polarity of one of the groups is then reversed, six pole motor operation results. An auxiliary stator winding which is similar to the main stator winding is displaced from the main stator winding by 90 electrical degrees on a two pole basis.

Kirschbaum, Herbert S. (Asheville, NC)

1984-01-01T23:59:59.000Z

70

Single phase two pole/six pole motor  

DOE Patents (OSTI)

A single phase alternating current two pole/six pole motor is provided with a main stator winding having six coils disposed unequally around the periphery of the machine. These coils are divided into two groups. When these groups are connected such that their magnetomotive forces are additive, two pole motor operation results. When the polarity of one of the groups is then reversed, six pole motor operation results. An auxiliary stator winding which is similar to the main stator winding is displaced from the main stator winding by 90 electrical degrees on a two pole basis. 12 figs.

Kirschbaum, H.S.

1984-09-25T23:59:59.000Z

71

Overhead elimination mechanisms in real-time systems  

Science Conference Proceedings (OSTI)

The OEM (Overhead Elimination Mechanism), a scheduler for finding minimal overheads with reduced context switches in real-time systems, was developed using procedural methods. Software produced by these methods has often proven to be inflexible and difficult ... Keywords: Real-time scheduling, context switches, object-oriented, procedural, rate monotonic algorithm

Ilhyun Lee; Haesun K. Lee; Narayan Debnath

2006-04-01T23:59:59.000Z

72

Microsoft Word - CX-CowlitzTaptoChehalis-CovingtonWoodPoles_WEB...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8, 2011 REPLY TO ATTN OF: KEPR-Covington SUBJECT: Environmental Clearance Memorandum Clay Grande Line Foreman III - TFCF-Covington Proposed Action: Wood pole replacement at...

73

Microsoft Word - CX-BigEddy-RedmondWoodPoles_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Clearance Memorandum Darrell Aaby Line Foreman III - TFDF-Redmond Proposed Action: Wood pole replacements at select locations along the Big Eddy-Redmond and Redmond-Pilot...

74

Power outages often spur questions around burying power lines ...  

U.S. Energy Information Administration (EIA)

Despite the cost, underground power lines are often found in urban areas, where the density of the required overhead wire would cause significant obstructions.

75

The South Pole Telescope  

E-Print Network (OSTI)

A new 10 meter diameter telescope is being constructed for deployment at the NSF South Pole research station. The telescope is designed for conducting large-area millimeter and sub-millimeter wave surveys of faint, low contrast emission, as required to map primary and secondary anisotropies in the cosmic microwave background. To achieve the required sensitivity and resolution, the telescope design employs an off-axis primary with a 10m diameter clear aperture. The full aperture and the associated optics will have a combined surface accuracy of better than 20 microns rms to allow precision operation in the submillimeter atmospheric windows. The telescope will be surrounded with a large reflecting ground screen to reduce sensitivity to thermal emission from the ground and local interference. The optics of the telescope will support a square degree field of view at 2mm wavelength and will feed a new 1000-element micro-lithographed planar bolometric array with superconducting transition-edge sensors and frequency-multiplexed readouts. The first key project will be to conduct a survey over approximately 4000 degrees for galaxy clusters using the Sunyaev-Zel'dovich Effect. This survey should find many thousands of clusters with a mass selection criteria that is remarkably uniform with redshift. Armed with redshifts obtained from optical and infrared follow-up observations, it is expected that the survey will enable significant constraints to be placed on the equation of state of the dark energy.

SPT Collaboration; J. E. Ruhl; P. A. R. Ade; J. E. Carlstrom; H. M. Cho; T. Crawford; M. Dobbs; C. H. Greer; N. W. Halverson; W. L. Holzapfel; T. M. Lantin; A. T. Lee; J. Leong; E. M. Leitch; W. Lu; M. Lueker; J. Mehl; S. S. Meyer; J. J. Mohr; S. Padin; T. Plagge; C. Pryke; D. Schwan; M. K. Sharp; M. C. Runyan; H. Spieler; Z. Staniszewski; A. A. Stark

2004-11-04T23:59:59.000Z

76

Microsoft Word - CX-Driscoll-NaselleWood PolesFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Memorandum Ryan Brady Line Foreman III - TFOK-Chehalis Proposed Action: In-kind wood pole replacements as needed on the Driscoll-Naselle No. 1 115-kV transmission line...

77

Tools and Methods to Perform Live Work on Reduced-Clearance Facilities: Electrical Performance of Pole Wraps and Guards: Electrical Performance of Pole Wraps and Guards  

Science Conference Proceedings (OSTI)

To ensure that transmission lines remain in service every day of the year, transmission owners are increasingly turning to live-line working techniques as standard practice. Earlier EPRI research showed that the ac performance of pole wraps and guards holds promise for use above stated ratings in live-line work. This report summarizes the results obtained from recent tests on pole wraps using ac and switching impulse voltages.

2003-11-19T23:59:59.000Z

78

Six pole/eight pole single-phase motor  

DOE Patents (OSTI)

A single phase alternating current electric motor is provided with a main stator winding having two coil groups which are connected to form eight poles for eight-pole operation and to form six poles for six-pole operation. Each group contains four series connected coil elements with each element spanning approximately one-seventh of the periphery of the machine. The coil groups are spaced 180 mechanical degrees apart such that each end coil of one group overlaps one of the end coils of the other group. An auxiliary stator winding having two coil groups with the same relative angular displacement as the main stator winding coil groups is included. 10 figs.

Kirschbaum, H.S.

1984-07-31T23:59:59.000Z

79

Kentucky Transmission Line Siting Methodology  

Science Conference Proceedings (OSTI)

EPRI, in conjunction with Georgia Transmission Corporation (GTC) and Photo Science, Inc. (PSI), developed a standardized methodology for siting overhead electric transmission lines. EPRI report 1013080, EPRI-GTC Overhead Electric Transmission Line Siting Methodology, published February 2006, provides additional information. This methodology has been applied in Georgia and currently is being applied to projects in Kentucky by East Kentucky Power Cooperative and E.ON U.S. on behalf of Louisville Gas and El...

2007-12-18T23:59:59.000Z

80

DOE-HDBK-1141-2001; Radiological Assessor Training, Overheads  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

13.1 13.1 Overhead 13.1 DOE-HDBK-1141-2001 Radiological Aspects of Accelerators Objectives: * Identify the general characteristics of accelerators. * Identify the types of particles accelerated. * Identify the two basic types of accelerators. * Identify uses for accelerators. * Define prompt radiation. * Identify prompt radiation sources. OT 13.2 Overhead 13.2 DOE-HDBK-1141-2001 Radiological Aspects of Accelerators (cont.) Objectives: * Define radioactivation. * Explain how contaminated material differs from activated material with regard to radiological concerns. * Identify activation sources. OT 13.3 Overhead 13.3 DOE-HDBK-1141-2001 Radiological Aspects of Accelerators (cont.) Objectives: * Identify engineered and administrative controls at accelerator facilities. * Identify the special

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Single phase four pole/six pole motor  

DOE Patents (OSTI)

A single phase alternating current electric motor is provided with a main stator winding having two coil groups each including the series connection of three coils. These coil groups can be connected in series for six pole operation and in parallel for four pole operation. The coils are approximately equally spaced around the periphery of the machine but are not of equal numbers of turns. The two coil groups are identically wound and spaced 180 mechanical degrees apart. One coil of each group has more turns and a greater span than the other two coils. 10 figs.

Kirschbaum, H.S.

1984-10-09T23:59:59.000Z

82

The Importance of Non-Data-Communication Overheads in MPI  

Science Conference Proceedings (OSTI)

With processor speeds no longer doubling every 18â??24 months owing to the exponential increase in power consumption and heat dissipation, modern high-end computing systems tend to rely less on the performance of single processing units and instead ... Keywords: Blue Gene/P, MPI, non-data-communication overheads

Pavan Balaji; Anthony Chan; William Gropp; Rajeev Thakur; Ewing Lusk

2010-02-01T23:59:59.000Z

83

Overhead reduction in a distributed path management system  

Science Conference Proceedings (OSTI)

CEAS (cross entropy ant system) is a distributed, robust and adaptive swarm intelligence system for path management in communication networks. This paper focuses on strategies for handling the overhead in terms of processing cycles, memory storage, and ... Keywords: Cross entropy, Path management, Swarm intelligence

Poul E. Heegaard; Otto J. Wittner

2010-04-01T23:59:59.000Z

84

--No Title--  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

D & R two utility pole(s) (K1239 K1242) and the overhead electrical line running from southwest of 184-K to existing utility pole K1238, and to install one new utility pole...

85

Structural Repairs for Transmission Structures: Anchors, Poles, and Lattice Construction  

Science Conference Proceedings (OSTI)

This document provides a brief overview of repair methods for transmission line lattice and pole structures and provides guidance on the complex financial issue of how to determine whether a corrosion repair should be accounted for as capital or expense.   BackgroundAs the North American electrical transmission system ages, many issues have to be addressed to keep the system functioning. The high voltage ...

2012-12-12T23:59:59.000Z

86

An Approach for Reduction of the Security Overhead in Smart Grid Communication Infrastructure Employing Dedicated Encryption  

E-Print Network (OSTI)

An Approach for Reduction of the Security Overhead in Smart Grid Communication Infrastructure for data secu- rity within the Smart Grid communications infrastructure. A significant part communication channels. Keywords--Smart Grid; information-communication infras- tructure; overheads; data

Kavcic, Aleksandar

87

Bounding Communication Energy Overhead in Parallel Networks with Power-Delay Scalability  

Science Conference Proceedings (OSTI)

We propose the energy scalability and power-delay product scalability as new metrics for calculating and estimating boundaries on the energy overhead of parallel processing systems. Because both properties consider network topology and the algorithm ... Keywords: energy overhead, communication overhead, energy scalability, power-delay scalability

James S. Tandon; Steven E. Butner

2008-12-01T23:59:59.000Z

88

CLOMP: Accurately Characterizing OpenMP Application Overheads  

SciTech Connect

Despite its ease of use, OpenMP has failed to gain widespread use on large scale systems, largely due to its failure to deliver sufficient performance. Our experience indicates that the cost of initiating OpenMP regions is simply too high for the desired OpenMP usage scenario of many applications. In this paper, we introduce CLOMP, a new benchmark to characterize this aspect of OpenMP implementations accurately. CLOMP complements the existing EPCC benchmark suite to provide simple, easy to understand measurements of OpenMP overheads in the context of application usage scenarios. Our results for several OpenMP implementations demonstrate that CLOMP identifies the amount of work required to compensate for the overheads observed with EPCC. Further, we show that CLOMP also captures limitations for OpenMP parallelization on NUMA systems.

Bronevetsky, G; Gyllenhaal, J; de Supinski, B

2008-02-11T23:59:59.000Z

89

Wood Poles Population with Testing  

Science Conference Proceedings (OSTI)

EPRI's asset management research focuses on developing a rational basis for selecting repair or replacement options for specific classes of equipment by balancing the risks of equipment failure against the costs of continued maintenance or capital replacement. This Model User Guide is a companion to Guidelines for Intelligent Asset Replacement: Volume 4Wood Poles (Expanded Edition), EPRI, Palo Alto, CA: 2006. 1012500, the fourth report on guidelines for asset replacement, which discusses methods for maki...

2006-12-18T23:59:59.000Z

90

Report on Wood Pole and Crossarm Degradation Modes  

Science Conference Proceedings (OSTI)

This report covers the typical types of wood used in transmission line construction. The species can be categorized by their level of corrosion resistance, the type of preservative treatment that is appropriate and the type of decay that is predominant. This market has the benefit of experience and training gained through years of pole maintenance practices, research and the techniques that migrate directly to crossarm maintenance.

2009-12-23T23:59:59.000Z

91

WindPole Ventures LLC | Open Energy Information  

Open Energy Info (EERE)

WindPole Ventures LLC WindPole Ventures LLC Jump to: navigation, search Logo: WindPole Ventures LLC Name WindPole Ventures LLC Address 48 Pleasant Street Place Lexington, Massachusetts Zip 02421 Sector Wind energy Product Will create, develop and operate commercial-scale wind powered electric generating facilities Website http://www.windpoleventures.co Coordinates 42.423694°, -71.207449° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.423694,"lon":-71.207449,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

92

Achieving Robustness and Minimizing Overhead in Parallel Algorithms Through Overlapped Communication/Computation  

Science Conference Proceedings (OSTI)

One of the major goals in the design of parallel processing machines and algorithms is to achieve robustness and reduce the effects of the overhead introduced when a given problem is parallelized or a fault occurs. A key contributor to overhead is communication ... Keywords: Proteus Parallel Computer System, communication overhead, complete exchange, fault tolerance, overlapping computing and communication, partitioning and scheduling for high-performance

Arun K. Somani; Allen M. Sansano

2000-05-01T23:59:59.000Z

93

DOE-HDBK-1143-2001; Radiological Control Training for Supervisors - Overheads  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Control Training for Supervisors Control Training for Supervisors DOE-HDBK-1143-2001 Overheads Office of Environment, Safety & Health U.S. Department of Energy Radiological Control Training for Supervisors DOE-HDBK-1143-2001 Overheads This page intentionally left blank. ii OT 1.1 DOE-HDBK-1143-2001 Overhead 1.1 Regulatory Documents Objectives: * Identify the hierarchy of regulatory documents. * Define the purposes of 10 CFR Parts 820, 830 and 835. * Define the purpose of the DOE Radiological Control Standard. OT 1.2 DOE-HDBK-1143-2001 Overhead 1.2 Regulatory Documents (cont.) Objectives: * Define the terms

94

Evaluation of Connector Mitigation Measures for Lines Operating at High Temperatures  

Science Conference Proceedings (OSTI)

Test results from a previous research conducted by the Electric Power Research Institute (EPRI) indicated that connectors on overhead lines operated above 100°C may fail from high temperatures. To allow an overhead line to operate at a temperature higher than the limit imposed by the connectors, research was initiated in 2009 to develop mitigation measures for the compression connectors that have a “high ...

2012-11-14T23:59:59.000Z

95

Simulation of atmospheric overvoltages on 400kV power lines in transmission system  

Science Conference Proceedings (OSTI)

External overvoltages are unambiguously caused by atmospheric overvoltages on overhead lines an emerges during storms. The paper presents simulation results of atmospheric overvoltages in slovak transmission system, which were realized in purpose of ... Keywords: overhead power lines, overvoltages, power system, surge arrester

Martin Mucha; Žaneta Eleschová; Anton Belá?; František Janí?ek; Peter Szathmáry

2006-09-01T23:59:59.000Z

96

Effective Methods in Reducing Communication Overheads in Solving  

NLE Websites -- All DOE Office Websites (Extended Search)

0/2002 Yun (Helen) He, GHC2002 1 0/2002 Yun (Helen) He, GHC2002 1 Effective Methods in Reducing Communication Overheads in Solving PDE Problems on Distributed-Memory Computer Architectures Chris Ding and Yun (Helen) He Lawrence Berkeley National Laboratory 10/10/2002 Yun (Helen) He, GHC2002 2 Outline n Introduction n Traditional Method n Ghost Cell Expansion (GCE) Method n GCE Algorithm n Diagonal Communication Elimination (DCE) Technique n Analysis of GCE Method n Message Volume n Communication Time n Memory Usage and Computational Cost n Performance n Test Problem n Test Results n Conclusions 10/10/2002 Yun (Helen) He, GHC2002 3 Background n On a distributed system, each processor holds a problem

97

A Negative-Overhead, Self-Timed Pipeline  

E-Print Network (OSTI)

This' paper presents' a novel variation of wave pipelining that we call "surfing." In previous wave pipelined designs, timing uncertainty grows' monotonically as events' propagate through gates or other logic elements'. We bound this dispersion by propagating a timing pulse along with the data values. Our logic elements have delays' that are smaller in the presence of the pulse than in its' absence. This' produces a "surfing " effect: events' are bound in close proximity to the timing pulse. We demonstrate this approach with the design of a 4x12 multiplier. Spice simulations from the extracted layout indicate that this design is robust in the presence of fabrication parameter variation and power supply noise. Because timing is' maintained by accelerating the logic, our designs achieve lower latency than their purely combinational equivalents'. Thus, the control overhead for these designs is' indeed negative.

Brian D. Winters; Mark R. Greenstreet

2002-01-01T23:59:59.000Z

98

Experience Based Seismic Verification Guidelines for Overhead Crane Systems: Volume I - Seismic Review Procedure; Volume II - Performance of Overhead Cranes in Strong Motion Earthquakes  

Science Conference Proceedings (OSTI)

This report provides guidelines that can be used to perform an experience-based seismic capability verification of overhead cranes systems at nuclear power plants. The report summarizes seismic experience data from strong-motion earthquakes for these systems and identifies the characteristics of systems that could lead to failure or unacceptable behavior in an earthquake. The seismic experience data show that overhead crane systems exhibit extremely good performance under strong-motion seismic loading, w...

2005-06-08T23:59:59.000Z

99

North Pole, Alaska: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Pole, Alaska: Energy Resources Pole, Alaska: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 64.7511111°, -147.3494444° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":64.7511111,"lon":-147.3494444,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

100

An analytical model for input-buffered optical packet switches with reconfiguration overhead  

Science Conference Proceedings (OSTI)

The overhead associated with reconfiguring a switch fabric in optical packet switches is an important issue in relation to the packet transmission time and can adversely affect switch performance. The reconfiguration overhead increases the mean waiting ... Keywords: Batch arrival, Discrete-time system, Optical communication, Stochastic analysis, Stochastic decomposition

Kuan-Hung Chou; Woei Lin

2011-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Cost-free scan: a low-overhead scan path design methodology  

Science Conference Proceedings (OSTI)

Conventional scan design imposes considerable area and delay overhead by using larger scan flip-flops and additional scan wires without utilizing the functionality of the combinational logic. We propose a novel low-overhead scan design methodology, called ... Keywords: Scan design, DFT, Testing

Chih-Chang Lin; Mike Tien-Chien Lee; Malgorzata Marek-Sadowska; Kuang-Chien Chen

1995-12-01T23:59:59.000Z

102

Transmission Line Design and Construction  

Science Conference Proceedings (OSTI)

The power industry wants to construct reliable and cost-effective overhead lines. A reliable and cost effective line requires not only that the line and structures meet design criteria for strength, clearances, and electrical considerations, but also that it be designed for safe and easy construction and maintenance. Design and construction practices should therefore go hand in hand. Information among various departments within a utility has to be shared for mutual benefit. Communication is a key ...

2012-12-31T23:59:59.000Z

103

Femtosecond second-harmonic generation in periodically poled lithium niobate  

E-Print Network (OSTI)

Femtosecond second-harmonic generation in periodically poled lithium niobate waveguides poled lithium niobate waveguides under large conversion conditions. Strong saturation of the SHG detailed experi- mental data on femtosecond SHG in periodically poled lithium niobate (PPLN) waveguides

Purdue University

104

Definition: DC Resistivity Survey (Pole-Dipole Array) | Open...  

Open Energy Info (EERE)

Pole-Dipole Array) Jump to: navigation, search Dictionary.png DC Resistivity Survey (Pole-Dipole Array) The Pole-Dipole array is a type of electrode configuration for a DC...

105

Microsoft Word - CX-AlveyDistWoodPoles_FY13_WEB.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alvey District Wood Pole Replacement Projects Alvey District Wood Pole Replacement Projects PP&A Project No.: 2663 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Various transmission lines located in Douglas, Linn, and Lane counties, Oregon. Refer to Project Location Attachment for transmission lines and corresponding structure locations. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace deteriorating wood poles and associated structural/electrical components (e.g. cross arms, insulators, guy anchors, etc.) along the subject transmission lines. Replacement will be in-kind and will utilize the existing holes to minimize ground disturbance. If necessary, an auger will be used to remove any loose soil from

106

Microsoft Word - CX-NorthBendWoodPoles_FY13_WEB.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

North Bend District Wood Pole Replacement Projects North Bend District Wood Pole Replacement Projects PP&A Project No.: 2658 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Various transmission lines located in Douglas, Linn, and Lane counties, Oregon. Refer to Project Location Attachment for transmission lines and corresponding structure locations. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace deteriorating wood poles and associated structural/electrical components (e.g. cross arms, insulators, guy anchors, etc.) along the subject transmission lines. Replacement will be in-kind and will utilize the existing holes to minimize ground disturbance. If necessary, an auger will be used to remove any loose soil from

107

Environmental Profile of Utility Distribution Poles  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) and member utilities requested Battelle to customize and demonstrate their streamlined, life cycle, environmental profile screening tool called LCPROFILESM as a decision support tool for utilities to compare the life cycle environmental impact potential associated with different types of distribution poles. In order to demonstrate that the screening tool can evaluate the full range of utility pole types, 16 environmental criteria were selected to evaluate the ...

2005-10-18T23:59:59.000Z

108

Practical on-line dvs scheduling for fixed-priority real-time systems  

E-Print Network (OSTI)

We present an on-line Dynamic Voltage Scaling (DVS) algorithm for preemptive fixed-priority real-time systems called low power Limited Demand Analysis with Transition overhead (lpLDAT). It is the first algorithm in its class to explicitly account for transition overhead, and can reduce the energy consumption by as much as 40 % when compared to previous methods. 1.

Bren Mochocki; Xiaobo Sharon Hu

2005-01-01T23:59:59.000Z

109

Inspection and Assessment of Overhead Transmission Line Hardware: State of Art Technologies and Future Development  

Science Conference Proceedings (OSTI)

This report provides background on the mechanisms of atmospheric corrosion and the environmental factors that affect it and describes an on-going research effort to develop  new field methods based on electrochemical impedance spectroscopy (EIS) and capacitance discharge rate (CDR) to assess the status of coating systems.BackgroundCoating systems provide a highly resistive barrier that prevents the environment from ...

2012-12-12T23:59:59.000Z

110

Field Guide: Daytime Discharge Inspection of Transmission and Distribution Overhead Lines and Substations – Guide with Video  

Science Conference Proceedings (OSTI)

This EPRI visual guide, one of a series of field guides designed to support inspection and assessment of transmission components, is devoted to the subject of daytime discharge inspection. Although technology for viewing corona and arcing discharges during the day has been available for a number of years, it can be rather difficult to interpret the images produced by this technology. This systematically organized document was prepared to help overcome some of these difficulties. It is intended for ...

2013-01-31T23:59:59.000Z

111

Microsoft Word - CX-Murray-CusterWoodPoles_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Covington Covington SUBJECT: Environmental Clearance Memorandum Steve Scott Line Foreman III - TFNF-Snohomish Proposed Action: Wood pole replacement at selected locations along the Murray-Custer #1 transmission line right-of-way (ROW). PP&A Project No.: 1963 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights-of-way, infrastructures such as roads, equipment... routine maintenance activities, corrective...are required to maintain...infrastructures...in a condition suitable for a facility to be used for its designed purpose. Location: The proposed project is located in Snohomish and Skagit Counties, Washington, in Bonneville Power Administration's (BPA) Snohomish District.

112

DOE/EA-1636: Albany-Burnt Woods and Santiam-Toledo Pole Replacement Project Mitigation Action Plan (March 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Burnt Woods and Santiam-Toledo Pole Replacement Project Burnt Woods and Santiam-Toledo Pole Replacement Project DOE/EA-1636 Summary This Mitigation Action Plan (MAP) is part of the Finding of No Significant Impact (FONSI) for the Albany-Burnt Woods and Santiam-Toledo Pole Replacement Project. The project involves replacing wood pole structures on about 26 miles of the Albany-Burnt Woods single-circuit, 115- kilovolt (kV) transmission line and about 21 miles of the Santiam-Toledo single circuit, 230-kV transmission line in Linn, Benton and Lincoln counties, Oregon. This MAP is for the Proposed Action and includes all of the integral elements and commitments made in the Environmental Assessment (EA) to mitigate any potential adverse environmental impacts. The purpose of this MAP is to explain how the mitigation measures will be

113

Microsoft Word - CX-WenatcheeDistrictPoleReplacementFY13_WEB.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2, 2013 2, 2013 REPLY TO ATTN OF: KEPR/Pasco SUBJECT: Environmental Clearance Memorandum Joseph Lauer Lineman Foreman III - TFWF-SCHULTZ Proposed Action: Wood pole replacement and minor access road maintenance along various transmission line right-of-ways in Bonneville Power Administration's (BPA) Wenatchee District. The following lines will have pole change-outs in 2013: Grandview-Red Mountain #1 and Columbia-Valhalla #2. PP&A Project No.: 2604 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities. Location: Various transmission lines located within the Wenatchee District. See Project Location Attachment for structure locations and corresponding transmission lines.

114

Causes and Effects of Microshocks Under Transmission Lines  

Science Conference Proceedings (OSTI)

Because the effect of a voltage on an overhead wire extends into the surrounding space, electric fields occur beneath overhead electric power transmission lines; and voltages are induced on nearby electrically conducting objects, whether vehicles, buildings, people, animals, or other similarly sized objects. Electric field induction can result in a current flow from the affected object to ground. This current flows to earth through the object's capacitance to ground and any parallel conducting ...

2013-10-07T23:59:59.000Z

115

CX-005487: Categorical Exclusion Determination | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

487: Categorical Exclusion Determination 487: Categorical Exclusion Determination CX-005487: Categorical Exclusion Determination D&R Two Utility Poles and Overhead Line and Install One Utility Pole and Overhead Line CX(s) Applied: B1.3 Date: 03/04/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office D&R two utility pole(s) (K1239/ K1242) and the overhead electrical line running from southwest of 184-K to existing utility pole K1238, and to install one new utility pole K1238A, Install a new overhead electrical line running from utility pole K1238 north to existing (UNIDENTIFIED) utility pole, then east to utility pole K1258, and install guywire(s), located south and southwest of 151-2K. DOCUMENT(S) AVAILABLE FOR DOWNLOAD CX-005487.pdf

116

Microsoft Word - CX-HillsCreek-LookoutPointWoodPolesFY12_WEB.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

REPLY TO ATTN OF: KEP-Alvey SUBJECT: Environmental Clearance Memorandum Chad Hamel Project Manager - TEP-TPP-1 Proposed Action: Hills Creek-Lookout Point No. 1 wood pole replacements PP&A Project No.: 2315 (WO# 297311) Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Lane County, Oregon Proposed by: Bonneville Power Administration (BPA), Alvey District Description of the Proposed Action: BPA proposes to replace four deteriorating wood pole structures and associated structural/electrical components (e.g. cross arms, insulators, guy anchors) along the subject transmission line. The poles are located on private residential and US Forest Service land. Landowners will be notified prior to replacement activities. Replacement will be in-

117

Microsoft Word - CX-PilotButte-LaPineWoodPoleFY12_WEB.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

30, 2012 30, 2012 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Richard Heredia Project Manager - TEP-TPP-1 Proposed Action: Pilot Butte-La Pine No. 1 Wood Pole Replacement Project PP&A Project No.: 2188 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6 Additions and modifications to transmission facilities ... include ... replacement of wood poles. Location: Pilot Butte-La Pine No. 1 transmission line located in Deschutes County, Oregon, at the following structures: Mile Structure 5 7 6 5 7 4 16 7 16 8 17 5 18 1 18 3 21 3 21 8 25 3 30 5 Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA is proposing to replace 12 deteriorating wood pole

118

EA-0962: Construction and Routine Operation of a 12-kilovolt Overhead  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

62: Construction and Routine Operation of a 12-kilovolt 62: Construction and Routine Operation of a 12-kilovolt Overhead Powerline and Formal Authorization for a 10-inch and 8-inch Fresh Water Pipeline Right-of-Way at Naval Petroleum Reserve No. 1, Kern County, California EA-0962: Construction and Routine Operation of a 12-kilovolt Overhead Powerline and Formal Authorization for a 10-inch and 8-inch Fresh Water Pipeline Right-of-Way at Naval Petroleum Reserve No. 1, Kern County, California SUMMARY This EA evaluates the environmental impacts of the proposal to install an overhead powerline extension from the U.S. Department of Energy's Naval Petroleum Reserve No. 1 (NPR-1) power source to the WKWD Station A, which will significantly reduce NPR-1's overall utility costs. NPR-1 is known as Elk Hills oil field and is located in the southern San Joaquin Valley,

119

A Neural Network Model for Construction Projects Site Overhead Cost Estimating in Egypt  

E-Print Network (OSTI)

Estimating of the overhead costs of building construction projects is an important task in the management of these projects. The quality of construction management depends heavily on their accurate cost estimation. Construction costs prediction is a very difficult and sophisticated task especially when using manual calculation methods. This paper uses Artificial Neural Network (ANN) approach to develop a parametric cost-estimating model for site overhead cost in Egypt. Fifty-two actual real-life cases of building projects constructed in Egypt during the seven year period 2002-2009 were used as training materials. The neural network architecture is presented for the estimation of the site overhead costs as a percentage from the total project price.

ElSawy, Ismaail; Razek, Mohammed Abdel

2011-01-01T23:59:59.000Z

120

Demonstration of Decision Tool for Selection of Distribution Poles  

Science Conference Proceedings (OSTI)

This report describes a Comprehensive Screening Tool (CST) for comparing different types of utility distribution poles. The completed tool permits utilities to evaluate distribution pole options using 26 criteria divided into engineering/technical performance, life cycle cost/economics, and environmental profile groups. The decision tool allows utilities to make a comprehensive evaluation of distribution pole options in an organized and semi-quantitative fashion across the full life cycle of the poles, i...

2006-10-30T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Demonstration of Decision Tool for Screening Eight Distribution Poles  

Science Conference Proceedings (OSTI)

This report updates the previously developed Poles Decision Tool (PDT) and demonstrates its use for eight distribution poles. The completed decision tool permits utilities to evaluate distribution pole options using 26 criteria divided between three evaluation groups for engineering/technical performance, life cycle cost/economics, and environmental profile. The decision tool allows utilities to make a comprehensive evaluation of distribution pole options in an organized and semi-quantitative fashion acr...

2008-09-02T23:59:59.000Z

122

Microsoft Word - CX-AlveyWoodPolesA-LE-AE-LH-AC-TBRT-FY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2012 Alvey District Wood Pole Replacement Projects 2012 Alvey District Wood Pole Replacement Projects PP&A Project No.: 2307 (Albany-Lebanon #1), 2309 (Blue River Tap), 2311 (Cougar- Thurston #1), 2312 (Eugene-Alvey #2), 2313 (Eugene-Lane #1), 2314 (Hawkins-Alvey #1) Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Various transmission lines located in Linn and Lane counties, Oregon. Refer to Project Location Attachment for transmission lines and corresponding structure locations. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace deteriorating wood poles and associated structural/electrical components (e.g. cross arms, insulators, guy anchors, etc.) along the subject transmission lines. Replacement will be in-kind and will utilize the existing holes to

123

Microsoft Word - CX-ChemawaWoodPolesCT-KFG12-KOCFGT-FY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2012 Chemawa District Wood Pole Replacement Projects 2012 Chemawa District Wood Pole Replacement Projects PP&A Project No.: 2325 (Carlton-Tillamook #1, Keeler-Forest Grove #2, Keeler-Oregon City #2, Keeler-Forest Grove #1, Forest Grove-Tillamook #1) Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Various transmission lines located in Washington, Yamhill, and Tillamook counties, Oregon. Refer to Project Location Attachment for transmission lines and corresponding structure locations. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace deteriorating wood poles and associated structural/electrical components (e.g. cross arms, insulators, guy anchors, etc.) along the subject transmission lines. Replacement will be in-kind and will utilize the existing holes to

124

Tracking down penguins at the poles  

E-Print Network (OSTI)

QCD penguins are responsible for about 2/3 of the Delta I=1/2 rule in K to pi pi decays, as inferred from a combined analysis of K to pi pi and KL to gamma gamma. Further tests based on the decays KS to pi0 gamma gamma and K+ to pi+ gamma gamma are proposed. New insights into the treatment of pi0, eta, eta' pole amplitudes are also reported.

Jean-Marc Gerard; Christopher Smith; Stephanie Trine

2006-05-14T23:59:59.000Z

125

Reduce Overhead, Implement Energy Efficiency in Water/Wastewater  

E-Print Network (OSTI)

Through the Focus on Energy program in the State of Wisconsin we have been able to identify savings for industries in their water/wastewater treatment or distribution systems. Modifications required to realize savings resulted in reduced energy consumption and reduced cost to industry. Reduced cost is a pleasant benefit when the cost of utility bills comes off the bottom line and if the industry is working on a 5 percent margin the actual value of the savings could be considered to be 20 times its actual savings. Modifications can be made in wastewater treatment applications by adjusting dissolved oxygen (DO) levels in treatment process, modifying aeration system blowers, changing diffusers, and considering a DO automatic control system. In water systems, changes in pump operations by not throttling valves for control, adding variable speed drives to constant speed operations, and reducing pressure on systems where it will not adversely impact the process.

Cantwell, J. C.

2007-01-01T23:59:59.000Z

126

Overhead energy considerations for efficient routing in wireless sensor networks q  

E-Print Network (OSTI)

Energy is the most critical resource in the life of a wireless sensor node. Therefore, its usage must be optimized to maximize the network life. It is known that for higher path loss exponent values, utilizing shorter communication links reduces the transmitter energy, whenever the radio equipment has power adjustment capability. Although the transmitter energy is one of the major factors of total energy dissipation, neglecting the overhead energy could result in suboptimal energy usage. Routing algorithms should also be concerned about the overhead energy which is wasted at each hop of data transfer. In this paper, we investigate the use of multi-hop communication links and compare the amount of energy gain upon alternative routes using analytical techniques. We show that employing multi-hop links does not always result in energy gain, and try to quantify situations when it is advantageous. The analytical results are used in routing decisions and their effect in energy efficiency is validated using simulations. Moreover, we also quantify the gain achieved in terms of lifetime by considering overhead energy on power adjustable sensors for different environmental conditions. We show that the network lifetime can dramatically decrease, if the overhead energy component is neglected during routing decisions.

E. Ilker Oyman; Cem Ersoy

2004-01-01T23:59:59.000Z

127

Multi-stage programming with functors and monads: Eliminating abstraction overhead from generic code  

Science Conference Proceedings (OSTI)

We use multi-stage programming, monads and Ocaml's advanced module system to demonstrate how to eliminate all abstraction overhead from generic programs, while avoiding any inspection of the resulting code. We demonstrate this clearly with Gaussian Elimination ... Keywords: Functor, Generative, Genericity, Linear algebra, MetaOCaml, Staging, Symbolic

Jacques Carette; Oleg Kiselyov

2011-05-01T23:59:59.000Z

128

Predicting energy and performance overhead of real-time operating systems  

Science Conference Proceedings (OSTI)

We present a high-level method for rapidly and accurately estimating energy and performance overhead of Real-Time Operating Systems. Unlike most other approaches, which rely on Transaction-Level Modeling (TLM), we infer the information we need directly ...

Sandro Penolazzi; Ingo Sander; Ahmed Hemani

2010-03-01T23:59:59.000Z

129

On-line Task Granularity Adaptation for Dynamic Grid Applications  

E-Print Network (OSTI)

On-line Task Granularity Adaptation for Dynamic Grid Applications Nithiapidary Muthuvelu1, Ian Chai by adjusting the task granularity at the grid scheduler. We propose an on-line scheduling algorithm which@csse.unimelb.edu.au Abstract. Deploying lightweight tasks on grid resources would let the commu- nication overhead dominate

Buyya, Rajkumar

130

Microsoft Word - CX-Redmond-PilotButte-WoodPoleFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3, 2012 3, 2012 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Richard Heredia Project Manager - TEP-TPP-1 Proposed Action: Redmond-Pilot Butte No. 1 Wood Pole Replacement Project PP&A Project No.: 2189 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6 Additions and modifications to transmission facilities Location: Redmond-Pilot Butte No. 1 transmission line in Deschutes County, Oregon at structures 4/7 and 11/6. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA is proposing to replace two deteriorating wood pole structures along its Redmond-Pilot Butte No. 1 230-kV transmission line located in Deschutes County, Oregon. The two structures

131

Microsoft Word - CX-TheDalles-DiscoveryWoodPolesFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3, 2012 3, 2012 REPLY TO ATTN OF: KEP-Alvey SUBJECT: Environmental Clearance Memorandum Richard Heredia Project Manager - TEP-TPP-1 Proposed Action: Wood Pole Replacement on The Dalles-Discovery #1 transmission line PP&A Project No.: 2323 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Project activities would take place in Wasco County, Oregon Line Corridor Structures TRS County, State The Dalles-Discovery #1 2/4, 2/5, 2/6, 2/9, 2/10 2N, 13E, Section 28 Wasco, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace deteriorating wood poles and associated structural/electrical components (e.g. cross arms, insulators, guy anchors, etc.) along the

132

Microsoft Word - CX Mid Way - Grand View Wood Pole Replacement-KEP.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

27, 2010 27, 2010 REPLY TO ATTN OF: KEP-4 SUBJECT: Environmental Clearance Memorandum Terry Kugler Lineman Foreman III - TFWF/Schultz Proposed Action: Replacing 11 wood pole structures on the Midway - Grandview transmission line and 12 wood pole structures on the Grandview - Red Mountain transmission line. PP&A Project No.: 1522 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): * B1.3 Routine maintenance activities for structures, rights-of-way, infrastructures (such as roads), are required to maintain infrastructures in a condition suitable for a facility to be used for its designed purpose. Routine maintenance may result in replacement to the extent that replacement is in kind and is not a substantial upgrade or improvement. In kind

133

Microsoft Word - CX-FY11PascoDistrictWoodPoleReplacement_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1, 2011 1, 2011 REPLY TO ATTN OF: KEPR-PASCO SUBJECT: Environmental Clearance Memorandum Toby Cossairt Lineman Foreman III - TFPF-PASCO Proposed Action: Wood pole replacement and minor access road maintenance along various transmission line rights-of-way (ROW) in the Pasco District. The following lines will have pole change-outs in 2011: Benton-Scooteney #1, Benton-Othello #1, Franklin-Hedges #1, Franklin-Walla Walla #1, Grandview-Red Mountain #1, Franklin-Badger Canyon #2, Kennewick Tap to Franklin- Badger Canyon #2, McNary-Franklin #2, and White Bluffs-Richland #1. Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights-of-way, infrastructures such as roads,

134

Microsoft Word - CX-ChemawaDistrictWoodPoles2013_FY13.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3 3 REPLY TO ATTN OF: KEP-Alvey SUBJECT: Environmental Clearance Memorandum Chad Hamel Project Manager - TEP-TPP-1 Proposed Action: 2013 Chemawa District Wood Pole Replacement Projects PP&A Project No.: 2736 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Various transmission lines located in Douglas, Linn and Lane counties, Oregon. Refer to Project Location Attachment for transmission lines and corresponding structure locations. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace deteriorating wood poles and associated structural/electrical components (e.g. cross arms, insulators, guy anchors, etc.) along the

135

Microsoft Word - CX-FY11WenatcheeDistrictWoodPoleReplacement_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4, 2011 4, 2011 REPLY TO ATTN OF: KEPR-PASCO SUBJECT: Environmental Clearance Memorandum Terry Kugler Lineman Foreman III - TFWF-SCHULTZ Proposed Action: Wood pole replacement and minor access road maintenance along various transmission line rights-of-way (ROW) in the Wenatchee District. The following lines will have pole change-outs in 2011: Chandler Tap, Grandview-Red Mt. #1 and Midway-Moxee #1. Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights-of-way, infrastructures such as roads, equipment... routine maintenance activities, corrective....are required to maintain... infrastructures...in a condition suitable for a facility to be used for its designed purpose.

136

Microsoft Word - CX-PilotButte-LaPine-WoodPoles-FY13_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3, 2013 3, 2013 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Richard Heredia Project Manager - TEP-TPP-1 Proposed Action: Wood pole replacements on Bonneville Power Administration's (BPA) Pilot Butte-La Pine No. 1 transmission line PP&A Project No.: 2484 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine Maintenance Location: Deschutes County, Oregon, at the following structures: Mile Structure 3 1 3 2 7 3 7 5 9 2 11 3 13 5 13 8 14 1 15 1 16 3 16 5 21 7 21 9 22 2 22 4 22 5 23 5 27 2 Proposed by: BPA Description of the Proposed Action: BPA is proposing to replace 19 deteriorating wood pole structures along its Pilot Butte-La Pine No. 1, 230-kilovolt transmission line located in Deschutes County, Oregon. The 19 structures

137

Microsoft Word - CX-RossDistrictWoodPolesFY13_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

9, 2013 9, 2013 REPLY TO ATTN OF: KEP-Alvey SUBJECT: Environmental Clearance Memorandum Stacie Hensley Realty Specialist - TEP-TPP-4 Proposed Action: 2013 Ross District Wood Pole Replacement Projects PP&A Project No.: 2737 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Various transmission lines located in Clark and Cowlitz counties, Washington, and , Columbia, Clatsop, and Washington counties, Oregon. Refer to Project Location Attachment for transmission lines and corresponding structure locations. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace deteriorating wood poles and associated structural/electrical components (e.g. cross arms, insulators, guy anchors, etc.) along the

138

Design of a portable CAT scanner for utility pole inspection  

SciTech Connect

Work is under way at the University of Missouri, Columbia (UMC) to design, build, and test a portable computerized axial tomography (CAT) device for the nondestructive, field imaging of wooden utility poles. CAT is a well-established medical technology that has recently been applied to a number of industrial applications. Wooden utility poles are prone to rot and decay at ground level; current techniques to assess this loss of strength are relatively primitive, i.e., tapping the pole (hitting the pole with a hammer) or boring into the pole for samples and then testing inside the bore hole with an electrical pulse device. The accuracy in identifying poles needing replacement using these techniques is approx. 70%. Since the cost of replacing a pole ranges from hundreds to thousands of dollars, an accurate, nondestructive method is needed. CAT can accurately image a wooden utility pole (since the size, density, and atomic elements of a pole are similar to the human head to torso), as was confirmed by imaging poles using the UMC nuclear engineering EMI-1010 medical scanner. Detailed images have been produced showing the ring structure of the wood and voids due to rot or decay. Images approaching this quality have also been produced on living trees using semiportable systems by other researchers.

Miller, W.H.

1986-01-01T23:59:59.000Z

139

Microsoft Word - CX-Alvey-FairviewAlvey-MartinCreek-DrainWoodPolesFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Wood pole replacements on the Alvey-Fairview No. 1 230-kV, Alvey- Wood pole replacements on the Alvey-Fairview No. 1 230-kV, Alvey- Martin Creek 115-kV, and Martin Creek-Drain #1 115-kV transmission line rights-of-way (ROW) PP&A Project No.: 2308 (WO# 297303), 2310 (WO# 297305), 2319 (WO# 297996) Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Alvey and Douglas counties, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace 18 deteriorating wood poles and associated structural/electrical components (e.g. cross arms, insulators, guy anchors, etc.) as well as cross arms on three other structures along the subject transmission lines. Replacement will be in-kind and will utilize the existing holes to minimize ground disturbance. If necessary, an auger

140

Honeybees and Power Line EMF Environments  

Science Conference Proceedings (OSTI)

This Resource Paper reviews research relevant to potential interactions between electric and magnetic field environments in the vicinity of high voltage overhead transmission lines. The paper deals first, with a description of a series of electric field studies conducted in a power line environment followed by mechanism studies under controlled conditions; second, with studies of the ability of bees to discriminate static and alternating magnetic fields; and third, with a study of native bees in a power ...

2010-12-06T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Demonstration of Decision Tool for Selection of Transmission Poles  

Science Conference Proceedings (OSTI)

EPRI and member utilities requested Battelle to develop a comprehensive screening tool (CST) for comparing different types of utility transmission poles by modifying the decision tool previously demonstrated on distribution poles. The completed decision tool permits utilities to evaluate transmission pole options using 26 criteria divided among three evaluation groups for engineering/technical performance, life-cycle cost/economics, and environmental profile. The decision tool allows utilities to evaluat...

2007-11-05T23:59:59.000Z

142

EPRI Transmission Line Reference Book: 115-345 kV Compact Line Design, The Blue Book  

Science Conference Proceedings (OSTI)

This report is an updated edition of the industry standard on overhead line compaction, the EPRI Transmission Line Reference Book: 115-138 kV Compact Line Design, commonly known as the "Blue Book," which was last published in 1978. Publication of this new edition is the culmination of three years of research by a team of experts in the field. The report includes the latest information on research, technology, materials, and utility experience with compact lines.

2008-11-05T23:59:59.000Z

143

Structural Behavior of FRP Lighting Pole System - Programmaster.org  

Science Conference Proceedings (OSTI)

Most of the lighting pole is made with steel and it is vulnerable to corrosion due to its hazardous surrounding environment. To mitigate such corrosion problems, ...

144

DOE/EA-1636: Finding of No Significant Impact for the Albany-Burnt Woods and Santiam-Toledo Pole Replacement Project EA (March 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Albany-Burnt Woods and Santiam-Toledo Pole Replacement Project Albany-Burnt Woods and Santiam-Toledo Pole Replacement Project Finding of No Significant Impact (FONSI) and Floodplain Statement of Findings DOE/EA-1636 Summary The Bonneville Power Administration (BPA) announces its environmental findings on the Albany- Burnt Woods and Santiam-Toledo Pole Replacement Project. This project involves replacing wood pole structures on the existing Albany-Burnt Woods single-circuit, 115-kilovolt (kV) transmission line and along a portion of the existing Santiam-Toledo single circuit, 230-kV transmission line. BPA has prepared an environmental assessment (DOE/EA-1636) evaluating the proposed project and its alternative. Based on the analysis in the EA, BPA has determined that the Proposed Action is not a major federal action significantly affecting the quality of the human environment, within the

145

Improved power transfer during single pole switching: A symmetrical sequence filtering approach  

Science Conference Proceedings (OSTI)

An innovative compensation scheme which allows three-phase AC transmission lines to be operated with one phase open, on a permanent basis, has been developed. Generally, the detrimental effects associated with the high levels of negative and zero sequence currents, generated during the single pole opening condition (SPO), preclude permanent operation of a line in only two phases. This new compensation strategy, also referred to as selective sequence filtering, confines the undesired sequence components of the current, produced during an SPO condition, to flow in a restricted region of the system.

Ciniglio, O.A. (Idaho Power Co., Boise (United States)); Carroll, D.P. (Univ. of Florida, Gainesville (United States))

1993-01-01T23:59:59.000Z

146

Evaluation of Emerging Line Inspection Technologies: Results of 2012 Outdoor Laboratory Tests  

Science Conference Proceedings (OSTI)

This report describes outdoor laboratory testing performed in 2012 to evaluate different approaches to establish conductor temperature during a helicopter-based Lidar field survey of an existing overhead transmission line. Establishing conductor temperature during Lidar surveys is necessary to assemble a line model to determine line sags, and thus clearances, under full rating and specified environmental conditions. ...

2013-09-26T23:59:59.000Z

147

Microsoft Word - CX_Maupin-TyghValley_PoleReplacement_FY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

, 2012 , 2012 REPLY TO ATTN OF: KEP-4 SUBJECT: Environmental Clearance Memorandum Richard Heredia Supervisory Civil Engineer - TEP-TPP-1 Proposed Action: Maupin-Tygh Valley #1 Pole Replacement Project Budget Information: Work Order #00297894 PP&A Project No.: 2196 Categorical Exclusions Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3, Routine maintenance Proposed by: Bonneville Power Administration (BPA) Location: Project activities would take place in Wasco County, Oregon, T04S R14E S20 Description of the Proposed Action: BPA proposes to replace one aged and unsound wood pole structure (structure 3/2) on the BPA Maupin-Tygh Valley #1 transmission line. The new structure would be placed in the same location and have the same appearance as the old

148

High-Voltage Direct Current Line Conductor Optimization  

Science Conference Proceedings (OSTI)

Overhead transmission lines are designed to last for 40 years. Many ac lines in service today in North America are 70 or more years old. This survival rate is a result of conservative utility design practices and detailed product specifications. This reliability record has occurred despite a wide range of conductor types and sizes. In the present transmission system, there are far fewer high-voltage direct current (HVDC) lines, but those that have been designed and built have been similarly successful in...

2011-12-21T23:59:59.000Z

149

Microsoft Word - CX-PacificCoWAWoodPolesFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6, 2012 6, 2012 REPLY TO ATTN OF: KEPR/Olympia SUBJECT: Environmental Clearance Memorandum Ryan Brady Line Foreman III - TFOK-Chehalis Proposed Action: Wood pole replacements as needed on the Naselle-Tarlett No. 1, Holcomb- Naselle No. 1, and Raymond-Willapa River No. 1, 115-kV transmission lines PP&A Project No.: 2367, 2368, and 2369; Work Order #: 298132, 298134, and 298133 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities Location: The subject transmission lines are located in Pacific County, Washington, in Bonneville Power Administration's (BPA) Chehalis Maintenance District. The transmission line right-of-way corridors cross public and privately-owned lands that include industrial

150

Microsoft Word - CX-PascoDistrictPoleReplacement_FY13_WEB.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3 3 REPLY TO ATTN OF: KEPR/Pasco SUBJECT: Environmental Clearance Memorandum Greg Wilfong Lineman Foreman III - TFPF-PASCO Proposed Action: Wood pole replacement and minor access road maintenance along the Franklin-Badger Canyon #2 and Walla Walla-Pendleton #1 transmission line rights-of-way in the Pasco District. PP&A Project No.: 2655 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities Location: Franklin-Badger Canyon #2 and Walla Walla-Pendleton #1 transmission lines located within the Pasco District. See table below for structure locations on the corresponding transmission lines: Transmission Line/ROW Structure # Township Range Section County, State Franklin-Badger Canyon

151

Microsoft Word - CX-Chehalis-CentraliaNo2WoodPolesFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0, 2012 0, 2012 REPLY TO ATTN OF: KEPR/Olympia SUBJECT: Environmental Clearance Memorandum Ryan Brady Line Foreman III - TFOK-Chehalis Proposed Action: Wood pole structure replacements on the Chehalis-Centralia No. 2 115-kV transmission line PP&A Project No.: 2372, WO# 298136 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities... Location: The subject transmission line is located in Lewis County, Washington, in Bonneville Power Administration's (BPA) Olympia Maintenance District. The transmission line ROW corridors cross public and privately-owned lands that are mostly rural residential property. No U.S. Forest service or tribal lands are within the project boundaries.

152

Microsoft Word - CX-Shelton-Fairmount-WoodPolesFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4, 2012 4, 2012 REPLY TO ATTN OF: KEPR/Olympia SUBJECT: Environmental Clearance Memorandum Lee Web Line Foreman III - TFOF-Olympia Proposed Action: Wood pole replacements as needed on the Shelton-Fairmount No. 1, 115-kV transmission line PP&A Project No.: 2371; Work Order # 298004 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities Location: The subject transmission line is located in Mason and Jefferson counties, Washington, in Bonneville Power Administration's (BPA) Olympia Maintenance District. The transmission line ROW corridors cross public and privately-owned lands that include industrial forestlands and rural residential property. Four structures requiring replacement including 43/1,

153

Estes-Flatiron Transmission Line Rebuild  

NLE Websites -- All DOE Office Websites (Extended Search)

Estes-Flatiron Transmission Line Rebuild Estes-Flatiron Transmission Line Rebuild Skip Navigation Links Transmission Functions Infrastructure projects Interconnection OASIS OATT Estes-Flatiron Transmission Line Rebuild Project Western Area Power Administration proposes to rebuild approximately 32 miles of double wood-pole structure 115-kilovolt transmission line that exists between Estes Park and Flatiron Reservoir in Larimer County, Colo. The proposal would remove 16 miles of transmission line, and modernize 16 miles to steel-pole double-circuit 115-kV transmission line. The reduction and modernizing of transmission lines will occur on Federal, state and private lands. The public parcels are administered by the Arapaho and Roosevelt National Forest, which is a cooperating agency in the project.

154

DC Resistivity Survey (Pole-Dipole Array) | Open Energy Information  

Open Energy Info (EERE)

Pole-Dipole Array) Pole-Dipole Array) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: DC Resistivity Survey (Pole-Dipole Array) Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Geophysical Techniques Exploration Sub Group: Electrical Techniques Parent Exploration Technique: Electrical Profiling Configurations Information Provided by Technique Lithology: Rock composition, mineral and clay content Stratigraphic/Structural: Detection of permeable pathways, fracture zones, faults Hydrological: Resistivity influenced by porosity, grain size distribution, permeability, fluid saturation, fluid type and phase state of the pore water Thermal: Resistivity influenced by temperature Dictionary.png

155

Managing Transmission Line Steel Structures, Version 2  

Science Conference Proceedings (OSTI)

Utilities are under more pressure than ever to efficiently utilize existing overhead lines by optimizing their life and reliability. A key issue involves the question of how to efficiently inspect and maintain transmission systems. In light of aging transmission and distribution infrastructures, resources are needed to design and implement cost-effective assessment and maintenance programs. This valuable reference provides an in-depth look at all facets of an inspection, assessment, and maintenance progr...

2004-12-02T23:59:59.000Z

156

EPRI Transmission Line Reference Book (Blue Book): 115-345 kV Compact Line Design  

Science Conference Proceedings (OSTI)

This report is an updated edition of the industry standard on overhead line compaction, the EPRI Transmission Line Reference Book: 115-138 kV Compact Line Design, commonly known as the Blue Book, which was last published in 1978. Publication of this new edition is the culmination of three years of research by a team of experts in the field. The report includes the latest information on research, technology, materials, and utility experience with compact lines. Note that this electronic report is being pu...

2007-12-13T23:59:59.000Z

157

Degradation Modes of Composite Crossarms and Poles, Desk Study  

Science Conference Proceedings (OSTI)

Lighting poles made entirely of Fiberglass Reinforced Polymer (FRP) material have been used since the 1960s; composite crossarm products are a relatively recent development for distribution circuits. This report provides background on various Fiberglass Reinforced Polymer (FRP) composite utility poles and crossarms, listing the available products and their associated attributes and identifying the causes of the degradation of these components. Product data and testing information for specific FRP ...

2012-12-12T23:59:59.000Z

158

A New Air Cerenkov Array at the South Pole  

E-Print Network (OSTI)

A New Air­ Ÿ Cerenkov Array at the South Pole J.E. Dickinson a J.R. Gill a S.P. Hart b;a G.C. Hill@sun.leeds.ac.uk) PACS codes: 96.40 (cosmic rays) 29.40.K ( Ÿ Cerenkov detectors) Abstract VULCAN comprises a 9 element array of air­ Ÿ Cerenkov radiation detectors estab­ lished at the South Pole. VULCAN operates

Delaware, University of

159

Microsoft Word - CX-AlveyDistrict_2011WoodPoles_No1957_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0, 2011 0, 2011 REPLY TO ATTN OF: KEP-Alvey SUBJECT: Environmental Clearance Memorandum Nick Wenzl John Carter Line Foreman III-TFE-Alvey Line Foreman I-TFE-Alvey Proposed Action: Wood pole replacements and minor access road maintenance along portions of the Eugene-Lane #1, Eugene-Alvey #2, and Hawkins-Alvey #1 transmission line rights-of- way (ROW) PP&A Project No: 1957 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights of way, infrastructures such as roads, equipment... routine maintenance activities, corrective....are required to maintain...infrastructures...in a condition suitable for a facility to be used for its designated purpose. Location: The project area is located in Lane County, Oregon, in Bonneville Power

160

Microsoft Word - CX-NBendFY11WoodPolesWEND-TAHK_TAHK-RDSPT_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 1 REPLY TO ATTN OF: KEP-Alvey SUBJECT: Environmental Clearance Memorandum Andy Crosby Todd Stringer Line Foreman III - TFEP-North Bend Line Foreman I - TFEP-North Bend Proposed Action: Wood pole replacement and minor access road maintenance along the Wendson-Tahkenitch #1 and the Tahkenitch-Reedsport #1 transmission line rights-of-way. PP&A Project No: 1960 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights-of-way, infrastructures such as roads, equipment... routine maintenance activities, corrective....are required to maintain...infrastructures...in a condition suitable for a facility to be used for its designated purpose. Location: The project area is located in Lane and Coos counties, Oregon, in Bonneville Power

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Microsoft Word - CX-GrandCoulee-ChiefJoseph_ARandWood Poles_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

REPLY TO ATTN OF: KEPR-Bell-1 SUBJECT: Environmental Cleareance Memorandum Todd Wehner Road Engineer - TELF-TPP-3 Robert Keudell Line Foreman III - TFWK-Grand Coulee Robert Zellar Line Foreman I - TFWK-Grand Coulee Proposed Action: Wood pole replacement, equipment landing construction and access road construction/maintenance along portions of the Grand Coulee-Chief Joseph #1 and #2 230-kV transmission line rights-of-way. PP&A Project No: 1777 Work Order No.: 275582 and 275583 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021):  B1.13 Construction, acquisition, and relocation of onsite pathways and short onsite access roads and railroads.  B1.3 Routine maintenance activities...for structures, rights-of-way, infrastructures such

162

Microsoft Word - CX-BadgerCanyon-RichlandNo1_WoodPoles_FY13.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7, 2013 7, 2013 REPLY TO ATTN OF: KEPR/Pasco SUBJECT: Environmental Clearance Memorandum Walker Miller Electrical Engineer - TPCF-W RICHLAND Proposed Action: Wood pole replacements on the Badger Canyon-Richland #1 transmission line PP&A Project No.: 2670 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities. Location: City of Richland, Benton County, WA Transmission Line/ROW Structure # Township Range Section County, State Badger Canyon-Richland #1 4/9 and 4/10 9N 28E 26 Benton, WA Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA, at the expense of the City of Richland, proposes to raise structures 4/9 and 4/10 of the Badger Canyon-Richland #1 115-kilovolt transmission line to

163

Beam-line cryopump  

DOE Green Energy (OSTI)

A cryopumping module using metallic surfaces at liquid helium temperature for condensation of hydrogen and deuterium gas has been constructed. This pump, a prototype of four units which will provide pumping for the Livermore 200 kV test stand, will be used to verify the concept and establish engineering parameters. Upon completion of engineering tests and evaluation the pump will be installed in an operating beam line. The design point pumping capacity is 80,000 liters per second for hydrogen and deuterium at 10$sup -4$ torr based on sticking coefficients of 0.15 and 0.25, respectively. Both the liquid helium temperature pumping surface and the liquid nitrogen temperature radiation shields are constructed of quilted double wall cylindrical shells. The pumping shell dimensions are 1.5 meters dia. x 0.6 meters long. Cryogen circulation is convection current driven in both cases. Liquid helium is supplied from an overhead Dewar through bayonet coupling. In the 200 kV beam line, pumping modules will be supplied via transfer lines from a central Dewar. Voltage standoff will be accomplished in the transfer lines. (auth)

Duffy, T.J.; Oddon, L.D.

1975-11-12T23:59:59.000Z

164

Mutual Design Considerations for Overhead AC Transmission Lines and Gas Transmission Pipelines, Volume 2: Prediction and Mitigation Procedures  

Science Conference Proceedings (OSTI)

Presents concise information on the prediction and mitigation of voltages and currents that were electromagnetically induced in pipelines.

1978-09-01T23:59:59.000Z

165

LPAT: An interactive simulation tool for assessing the lightning performance of Hellenic high voltage transmission lines  

Science Conference Proceedings (OSTI)

The paper presents the Lightning Performance Assessment Tool (LPAT), an interactive simulation tool which assesses the lightning performance of high voltage transmission lines. The LPAT design was based on a recently published methodology that has been ... Keywords: Lightning performance, Optical transient density, Overhead transmission lines, Simulation, Software tool, User interface

P. Karampelas; L. Ekonomou; S. Panetsos; G. E. Chatzarakis

2011-01-01T23:59:59.000Z

166

CX-006706: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

line from (existing) pole 99 to the Ten Sleep location for a new generator. The transformer bank at the WDF will be dismantled, the line extended overhead, across 5 new power...

167

Study of Vehicle Front Structure Crashworthiness Based on Pole Impact with Different Position  

Science Conference Proceedings (OSTI)

Because of occupant injury severity in frontal pole impact, this paper conducted a computer simulation study on the frontal pole impact of passenger car. Three types of frontal pole impact FE analysis models were developed according to different impact ... Keywords: Frontal pole impact, Impact position, Vehicle Structure Deformation, Crashworthiness

Qihui Li, Jikuang Yang

2013-01-01T23:59:59.000Z

168

Electric power high-voltage transmission lines: Design options, cost, and electric and magnetic field levels  

SciTech Connect

This report provides background information about (1) the electric and magnetic fields (EMFs) of high-voltage transmission lines at typical voltages and line configurations and (2) typical transmission line costs to assist on alternatives in environmental documents. EMF strengths at 0 {+-} 200 ft from centerline were calculated for ac overhead lines, and for 345 and 230-kV ac underground line and for a {+-}450-kV dc overhead line. Compacting and height sensitivity factors were computed for the variation in EMFs when line conductors are moved closer or raised. Estimated costs for the lines are presented and discussed so that the impact of using alternative strategies for reducing EMF strengths and the implications of implementing the strategies can be better appreciated.

Stoffel, J.B.; Pentecost, E.D.; Roman, R.D.; Traczyk, P.A.

1994-11-01T23:59:59.000Z

169

Guide for Operating Lines at High Temperatures: 2013 Update  

Science Conference Proceedings (OSTI)

Faced with difficulties in acquiring rights-of-way and reduced capital budgets for new transmission lines, many electric energy companies are seeking ways to extract more capacity from existing systems. One option for increasing power flow is to operate overhead transmission lines at higher temperatures than originally designed, an inexpensive option that can be accomplished quickly. It is, however, important that utilities understand the short- and long-term effects of high operating temperatures ...

2013-12-09T23:59:59.000Z

170

Guide for the Application of Transmission Line Surge Arrestors  

Science Conference Proceedings (OSTI)

Lightning flashovers are the most frequent cause of transmission line outages, resulting in a direct cost to utilities of more than $1 billion per year in damaged or destroyed equipment. There are also substantial indirect costs involved due to the reduction in power quality caused by frequent lightning outages. The lightning performance of transmission lines is usually improved by installing overhead ground or shield wires or by increasing the tower footing resistance; however, in some cases, these meas...

2009-12-21T23:59:59.000Z

171

Strategy for Updating EPRI's Transmission Line Reference Book: 115-138-kV Compact Line Design ("The Blue Book")  

Science Conference Proceedings (OSTI)

EPRI is sponsoring development of a new, updated edition of the Transmission Line Reference Book: 115-138 kV Compact Line Design, commonly known as the "Blue Book," which was originally published in 1978. The new edition will provide the most up-to-date technical information and practices on the design and maintenance of compact overhead lines. It will enable energy companies to construct cost-effective compact lines that produce optimal performances and to address the ability to maintain compact lines w...

2006-10-30T23:59:59.000Z

172

Predicting the Failure of Line Post Insulator Mounting Studs Due to Aeolian Vibrations  

Science Conference Proceedings (OSTI)

This report provides experimental and numerical investigations of the line post insulator stud failures experienced by APS (Arizona Public Service) on its 69kV and 22 kV overhead power lines. The project developed a numerical model conforming to the dynamics of a line post insulator and the coupling between neighboring spans. This model can be used in estimating the dynamic loads induced on a line post insulator from Aeolian (wind-induced) vibration.

2006-06-07T23:59:59.000Z

173

Microsoft Word - CX-LaPine-ChiloquinWoodPoleFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 2 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Richard Heredia Project Manager - TEP-TPP-1 Proposed Action: La Pine-Chiloquin No. 1 Wood Pole Replacement Project PP&A Project No.: 2236 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6, Additions and modifications to transmission facilities Location: La Pine-Chiloquin No. 1 230-kV transmission line in Klamath County, Oregon, at the following structure locations: 11/5, 16/1, 16/4, 17/3, 17/8, 18/2, 18/3, 20/4, 22/2, 22/5, 28/1, 42/3, 43/6, 44/4, and 45/1. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA is proposing to replace 15 deteriorating wood pole structures along its La Pine-Chiloquin 230-kV transmission line located in Klamath County,

174

Microsoft Word - CX-Drummond-MacksInn-WoodPoleReplacementFY13_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

29, 2012 29, 2012 REPLY TO ATTN OF: KEP-CELILO SUBJECT: Environmental Clearance Memorandum Mark Hadley Lineman Foreman III - TFIF-Idaho Falls Proposed Action: Wood pole replacements along the Drummond-Macks Inn, Macks Inn- Madison, and Swan Valley-Teton 115-kilovolt (kV) transmission line rights-of-way. PP&A Project Number: 2486 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities Location: The project area is located in Bonneville Power Administration's (BPA) Idaho Falls District. Project locations are listed below: Project Location Township Range Section(s) County Line Name Structures Use Ownership 3N 44E 28 Teton Swan Valley - Teton 10/6 Forest Forest Service 14S 5E 19 Fremont

175

Microsoft Word - CX-Cardwell-Cowlitz2011WoodPoles_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 1 REPLY TO ATTN OF: KEP-4 SUBJECT: Environmental Clearance Memorandum Erich Orth Project Manager - TEP-TPP-3 Proposed Action: Replacement of all aging wood pole transmission line support structures along the Cardwell-Cowlitz No. 1, 115-kilovolt (kV) transmission line Budget Information: Work Order #00279267 PP&A Project No.: 2021 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities... for...rights of way, infrastructures (e.g.. structures)... routine maintenance activities, corrective...are required to maintain and preserve infrastructures...in a condition suitable for the facility to be used for its designated purpose. Location: The project area is located along Bonneville Power Administration's (BPA)

176

Microsoft Word - CX-Drummond-MacksInn_WoodPoleReplacementFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

10, 2012 10, 2012 REPLY TO ATTN OF: KEP-CELILO SUBJECT: Environmental Clearance Memorandum Mark Hadley Lineman Foreman III - TFIF-Idaho Falls Proposed Action: Wood pole replacements along the Drummond-Macks Inn, Macks Inn- Madison, and Targhee Tap 115-kV transmission line rights-of-way. PP&A Project Number: 2191 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities... Location: The project area is located in Bonneville Power Administration's (BPA) Idaho Falls District. Project locations are listed below: Project Location Township Range Section(s) County Line Name Structures Use Ownership 4N 45E 11 Teton Targhee Tap 8/8 Agriculture Private 14N 44E 22 Fremont Macks Inn- Madison

177

Microsoft Word - CX-EllensburgTLMDistrictFY11WoodPoleReplacement_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Clearance Memorandum Clearance Memorandum Terry Kugler Lineman Foreman III - TFWF-Schultz Joe Lauer Line Foreman I - TFWF-Schultz Proposed Action: Wood pole replacement and minor access road maintenance along portions of the Columbia-Valhalla #1 and #2 transmission line rights-of-way. PP&A Project No: 1851 (Columbia-Valhalla #1), 1852 (Columbia-Valhalla #2) Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights of way, infrastructures such as roads, equipment... routine maintenance activities, corrective....are required to maintain...infrastructures...in a condition suitable for a facility to be used for its designed purpose. Location: The project area is located in Douglas and Chelan counties, Washington. Project

178

Microsoft Word - CX-RedmondWoodPoles_multiSub_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

15, 2011 15, 2011 REPLY TO ATTN OF: KEP-Celilo SUBJECT: Environmental Clearance Memorandum Darrell Aaby Line Foreman III - TFDF-Redmond Proposed Action: Wood pole replacement at selected locations along the La Pine - Chiloquin and Brasada - Harney No. 1 transmission line right-of-ways. PP&A Project No.: 1930 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights-of-way, infrastructures such as roads, equipment... routine maintenance activities, corrective...are required to maintain...infrastructures...in a condition suitable for a facility to be used for its designed purpose. Location: The proposed project is located in Klamath, Deschutes, and Harney counties,

179

Microsoft Word - CX-Chehalis-OlympiaChehalis-MayfieldLewisCoWoodPolesFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 2 REPLY TO ATTN OF: KEPR/Olympia SUBJECT: Environmental Clearance Memorandum Lee Webb Ryan Brady Line Foreman III - TFOF-Olympia TFOK-Chehalis - Line Foreman III Proposed Action: Wood pole structure replacements on the Chehalis-Olympia No. 1 and Chehalis-Mayfield No. 1, 115-kV transmission lines PP&A Project No.: 2370 & 2373, Work Order # 298130, 298138, and 297997 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities... Location: The subject transmission lines are located in Lewis and Thurston counties, Washington, in Bonneville Power Administration's (BPA) Olympia Maintenance District. The transmission line right-of-way (ROW) corridors cross public and privately-owned lands that

180

The extensions of gravitational soliton solutions with real poles  

E-Print Network (OSTI)

We analyse vacuum gravitational "soliton" solutions with real poles in the cosmological context. It is well known that these solutions contain singularities on certain null hypersurfaces. Using a Kasner seed solution, we demonstrate that these may contain thin sheets of null matter or may be simple coordinate singularities, and we describe a number of possible extensions through them.

J. B. Griffiths; S. Micciche

1998-11-02T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Comparison of prediction and measurement of negative sequence currents of generators connected to 345-kV asymmetrical transmission lines  

Science Conference Proceedings (OSTI)

This paper is used to evaluate the negative sequence currents (NSC) of two generators in a generation plant, which are connected to the power pool through four over-head asymmetrical 345-kV transmission lines. The simulation results by using PSS/E and ... Keywords: EMTP, PSS/E, asymmetrical transmission lines, negative sequence current, unbalance

Chi-Jui Wu; Ping-Heng Ho

2011-03-01T23:59:59.000Z

182

EA-1931: Keeler-Forest Grove, Forest Grove-Tillamook Line No. 1 Line Rebuild Project, Washington and Tillamook Counties, Oregon  

Energy.gov (U.S. Department of Energy (DOE))

This EA will evaluate the potential environmental impacts of a BPA proposal to rebuild its 58 mile long, 115 kilovolt (kV) wood pole Keeler-Forest Grove and Forest Grove-Tillamook transmission lines. The deteriorated transmission line structures (wood pole structures, switches, cross arms, braces, guys, anchors, insulator assemblies and conductor) need to be replaced in order to maintain reliable electrical service, avoid risks to the public, and ensure worker safety.

183

Motion planning of inspection robot suspended on overhead ground wires for obstacle-navigation  

Science Conference Proceedings (OSTI)

The purpose of inspection robot for power transmission lines is to check running state and find damages of extra-high voltage (EHV) power transmission lines equipment. The key of the control design is how to design a robot for obstacles navigation. This ... Keywords: centroid adjustment, inspection robot, obstacles navigation automatically, power transmission line

Ren Zhi-Bin; Ruan Yi; Li Zheng; Yang Yong

2009-06-01T23:59:59.000Z

184

EGGS (Guide for Transmission Line Grounding: A Roadmap for Design Testing and Remediation), Version 2.1  

Science Conference Proceedings (OSTI)

The EPRI Grounding Guide Software (EGGS), Version 2.1, is calculation/modeling software for transmission line grounding. EGGS Version 2.1, is a set of applets to assist technical staff in the design and implementation of effective grounding of transmission lines and is intended for users who need simple methods to evaluate new or existing transmission line grounding electrode designs. When ordering EGGS 2.1, included will be product 1018973, EPRIs Overhead Transmission Line Lightning and Grounding Refere...

2008-12-22T23:59:59.000Z

185

An Assessment of the Potential for Remanufacturing Out-of-Service Southern Pine Utility Poles  

Science Conference Proceedings (OSTI)

EPRI engaged The Beck Group (BECK), a forest products consulting firm located in Portland, Oregon, to estimate the supply and quality of out-of-service Southern Pine utility poles and to assess the potential for remanufacturing/reusing and marketing out-of-service utility poles into various solid, roundwood and other products. This report principally identifies the potential volumes and condition of out-of-service utility poles from cooperating utilities that use primarily Southern Pine poles. The report...

2007-03-09T23:59:59.000Z

186

APPLICATION OF A CATEGORICAL EXCLUSION  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

American Electric Power (AEP) for the installation and maintenance of an overhead 7.2kv electrical power line from an existing AEP power pole located on U S Department of Energy...

187

CX-007786: Categorical Exclusion Determination | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

of a permit to American Electric Power (AEP) for the installation and maintenance of an overhead 7.2 kilovolt electrical power line from an existing AEP power pole located on U S...

188

Coded excitation of broadband terahertz using optical rectification in poled lithium niobate  

E-Print Network (OSTI)

Coded excitation of broadband terahertz using optical rectification in poled lithium niobate T optical rectification of femtosecond laser pulses in poled lithium niobate patterned with a 53-bit binary forms can be generated by optical rectification in poled lithium niobate PLN . A femtosecond laser pulse

Buma, Takashi

189

High-repetition-rate femtosecond optical parametric oscillator based on periodically poled lithium niobate  

E-Print Network (OSTI)

High-repetition-rate femtosecond optical parametric oscillator based on periodically poled lithium periodically poled lithium niobate is described. This optical parametric oscillator is continuously tunable American Institute of Physics. S0003-6951 97 04325-8 Periodically poled lithium niobate PPLN has emerged

Fejer, Martin M.

190

Green Power Transmission Line Given New Life | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Green Power Transmission Line Given New Life Green Power Transmission Line Given New Life Green Power Transmission Line Given New Life March 11, 2010 - 4:34pm Addthis Poles for the Montana-Alberta Tie Line are unloaded outside Shelby, Mont. | Photo courtesy of Tonbridge Power Poles for the Montana-Alberta Tie Line are unloaded outside Shelby, Mont. | Photo courtesy of Tonbridge Power Stephen Graff Former Writer & editor for Energy Empowers, EERE Thanks to funds from the American Recovery and Reinvestment Act, construction of a green power transmission line stretching from Lethbridge, Alberta in Canada, down to Great Falls, Mont., was put back on track after a bank failure. Currently under construction, the Montana-Alberta Tie Line, which is owned by Toronto-based Tonbridge Power, will connect the electricity markets of

191

Ga-based passive loop optimization for magnetic field mitigation of transmission lines  

Science Conference Proceedings (OSTI)

This paper presents a systematic method to assist in the design of passive loops with the aim of mitigating the magnetic field generated by overhead transmission lines. The procedure is based on a two-dimensional (2D) modeling of the magnetic field, ... Keywords: Compensated loop, Genetic algorithm, Magnetic field, Mitigation, Passive loop, Reduction factor

Pedro Cruz; Jesús M. Riquelme; Antonio de la Villa; José L. Martínez

2007-10-01T23:59:59.000Z

192

Microsoft Word - CX-Big Eddy-Redmond-WoodPolesFY13_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4, 2013 4, 2013 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Richard Heredia Project Manager - TEP-TPP-1 Proposed Action: Big Eddy-Redmond No. 1 Wood Pole Replacement Project PP&A Project No.: 2500 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Big Eddy-Redmond No. 1 transmission line in Deschutes County, Oregon, at the following locations: Mile Structure Township Range Section 35 6 5 14 24 36 6 5 14 25 36 7 5 14 25 36 8 5 14 25 37 6 5 14 36 40 9 6 15 18 43 2 6 15 29 48 4 7 1 21 49 1 7 1 21 50 6 7 15 33 51 8 8 15 5 52 8 8 15 8 53 3 8 15 8 54 2 8 15 17 56 1 8 1 30 58 2 9 14 1

193

Microsoft Word - CX-Brasada-Harney-WoodPoles_FY13_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2, 2013 2, 2013 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Richard Heredia Project Manager - TEP-TPP-1 Proposed Action: Brasada-Harney No. 1 Wood Pole Replacement Project PP&A Project No.: 2187 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Brasada-Harney No. 1 transmission line in Deschutes and Harney counties, Oregon, at the following locations: Mile Structure Landowner Township Range Section 23 8 Private 19 16 22 26 6 BLM 19 17 30 28 1 BLM 19 17 32 29 2 Private 19 17 4 29 5 Private 19 17 4 29 7 BLM 19 17 4 30 8 Private 19 17 10 31 5 BLM 19 17 11 46 5 DSL 21 19 13 49 8 BLM 21 20 21

194

Microsoft Word - CX-KalispellTLMDistrictFY11WoodPoleReplacement_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cleareance Memorandum Cleareance Memorandum Michael Stolfus Lineman Foreman III - TFKF-Kalispell Kurt Marsh Lineman Foreman I - TFKF-Kalispell Proposed Action: Wood pole replacement and minor access road maintenance along various transmission line rights-of-way in Bonneville Power Administration's (BPA) Kalispell District. PP&A Project No: 1839 (Garrison-Anaconda #1), 1840 (Hot Springs-Rattlesnake #1), 1841 (Rattlesnake-Garrison #1), 1842 (Columbia Falls-Kalispell #1), 1843 (Kalispell-Kerr #1), 1844 (Libby-Bonners Ferry #1), 1845 (Columbia Falls-Trego #1) Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights of way, infrastructures such as roads, equipment... routine maintenance activities, corrective....are required to maintain...infrastructures...in a

195

Microsoft Word - CX-CentraliaTap_Chehalis-Covington_TransAlta_WoodPoles_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6, 2011 6, 2011 REPLY TO ATTN OF: KEP-4 SUBJECT: Environmental Clearance Memorandum Chad Caldwell Customer Service Engineer - TPC-Olympia Proposed Action: Replace aging wood poles on Trans Alta's Centralia Tap to Chehalis- Covington No. 1 230-kV transmission line. Budget Information: As per agreement with Trans Alta PP&A Project No.: N/A Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities... for...rights-of-way, infrastructures (e.g.. roads)... routine maintenance activities, corrective...are required to maintain and preserve infrastructures...in a condition suitable for the facility to be used for its designated purpose. Location: The project is located on Trans Alta's Centralia Tap to Chehalis-Covington No. 1

196

Microsoft Word - CX-FY10_Kalispell_District_Wood_Pole_Replacement_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6, 2010 6, 2010 REPLY TO ATTN OF: KEPR-Bell-1 SUBJECT: Environmental Cleareance Memorandum Michael Stolfus Lineman Foreman III - TFKF-Kalispell Proposed Action: Wood pole replacement and minor access road maintenance along various transmission line right-of-ways in the Kalispell District PP&A Project No: 1536 (Columbia Falls-Kalispell #1), 1537 (Anaconda-Silver Bow #1), 1538 (Columbia Falls-Trego #1), 1541 (Libby-Bonners Ferry #1), 1542 (Rattlesnake-Garrison #1) Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights-of-way, infrastructures such as roads, equipment... routine maintenance activities, corrective....are required to maintain...infrastructures...in a

197

Microsoft Word - CX-Minidoka-Unity_Wood PoleReplacementFY12_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

, 2012 , 2012 REPLY TO ATTN OF: KEP-CELILO SUBJECT: Environmental Clearance Memorandum Mark Hadley Lineman Foreman III - TFIF-Idaho Falls Proposed Action: Wood pole replacement along the Minidoka Power House-Unity No. 1 and Unity-Heyburn No. 1, 138-kV transmission line rights-of-way. PP&A Project No.: 2192 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights-of-way, infrastructures such as roads, equipment... routine maintenance activities, corrective....are required to maintain... infrastructures...in a condition suitable for a facility to be used for its designated purpose. Location: The project area is located in Cassia County, Idaho, in Bonneville Power

198

Evaluation of Member-Supplied Crossarms and Poles  

Science Conference Proceedings (OSTI)

Very little information pertaining to the design, installation, troubleshooting, and maintenance of fiberglass-reinforced polymer (FRP) poles and crossarms is available. This report summarizes an industry literature review, an Electric Power Research Institute (EPRI) member survey, and a survey of manufacturers in order to identify gaps in each of the critical areas that support the use of FRP materials in power utility distribution and transmission ...

2012-12-12T23:59:59.000Z

199

Atmospheric neutrino flux at INO, South Pole and Pyhäsalmi  

E-Print Network (OSTI)

We present the calculation of the atmospheric neutrino fluxes for the neutrino experiments proposed at INO, South Pole and Pyh\\"asalmi. Neutrino fluxes have been obtained using ATMNC, a simulation code for cosmic ray in the atmosphere. Even using the same primary flux model and the interaction model, the calculated atmospheric neutrino fluxes are different for the different sites due to the geomagnetic field. The prediction of these fluxes in the present paper would be quite useful in the experimental analysis.

M. Sajjad Athar; M. Honda; T. Kajita; K. Kasahara; S. Midorikawa

2012-10-18T23:59:59.000Z

200

Means and method for nonuniform poling of piezoelectric transducers  

DOE Patents (OSTI)

An apparatus and method for nonuniform poling of piezoelectric transducers includes machining one or more indentation into an end of a piezoelectric rod and cutting the rod to present a thickened disk shape. Highly electrically conductive material is deposited on at least the indentations in the one end and on at least portions of the opposite face of the member. One or more electrodes are configured to matingly fit within the indentations on the one face of the disk, with a like number of electrodes being positionable on the opposite face of the material. Electrical power is then applied to the electrodes in desired amounts, polarity, and duration. The indentations vary the electrical field produced within the piezoelectric material to produce nonuniform poling in the material. The thick disk is then cut to remove the indentations and to present a thin, flat two sided disk for installation in a conventional piezoelectric transducer probe. The indentations are selected to produce poling in accordance with desired transducer response profiles such as Gaussian or Bessel functions.

Hsu, David K. (Ames, IA); Margetan, Frank J. (Ames, IA); Hasselbusch, Michael D. (Ames, IA); Wormley, Samuel J. (Ames, IA); Hughes, Michael S. (Ames, IA); Thompson, Donald O. (Ames, IA)

1990-10-09T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Optimization of Transmission Line Design Using Life Cycle Costing  

Science Conference Proceedings (OSTI)

When an overhead line is designed, all costs incurred during the expected life of the line should be considered. The total cost during the life or life-cycle cost of a transmission line is a combination of the initial capital cost, operation and maintenance (O&M) cost, cost of electrical losses over its entire life, and dependability associated costs. The option that has the lowest life-cycle cost is selected as the optimized design. A tool is required by utility engineers to help them readily select an ...

2009-12-22T23:59:59.000Z

202

Optimization of Transmission Line Design Using Life-Cycle Costing  

Science Conference Proceedings (OSTI)

When an overhead line is designed, all costs incurred during the expected life of the line should be considered. The total cost during the life, or life-cycle cost, of a transmission line is a combination of the initial capital cost, operation and maintenance (O&M) cost, cost of electrical losses over its entire life, and dependability-associated costs. The option that has the lowest life-cycle cost is selected as the optimized design. A tool is required by utility engineers to help them readily select a...

2008-12-09T23:59:59.000Z

203

Ratings of Transmission Lines: Applications, Computations, and Thermal Models  

Science Conference Proceedings (OSTI)

The thermal rating of overhead transmission lines can be complex, because there is no way to directly measure the line rating and because high current load events occur only rarely in most parts of the power system. A thermal line rating is a prediction of how the conductor will behave thermally, mechanically, and electrically in the event of a high electrical current. It is possible to calculate ratings incorrectly and not discover that this is true until a most inopportune timeduring a system emergency...

2011-12-16T23:59:59.000Z

204

North Pole's Holiday Wish for An Energy Efficient 2012 | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

North Pole's Holiday Wish for An Energy Efficient 2012 North Pole's Holiday Wish for An Energy Efficient 2012 North Pole's Holiday Wish for An Energy Efficient 2012 December 23, 2011 - 4:20pm Addthis The city of North Pole, Alaska, is hoping to use $100,000 in Energy Efficiency and Conservation Block Grant funds to improve the energy efficiency of several key city facilities.| Photo courtesy of the a href"http://www.northpolefire.org/">North Pole Fire Department. The city of North Pole, Alaska, is hoping to use $100,000 in Energy Efficiency and Conservation Block Grant funds to improve the energy efficiency of several key city facilities.| Photo courtesy of the a href"http://www.northpolefire.org/">North Pole Fire Department. Chris Galm Marketing & Communications Specialist, Office of Energy Efficiency &

205

Proposed Project: Plains & Eastern Clean Line | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Section 1222 of the Energy Policy Act 2005 » Proposed Project: Plains & Section 1222 of the Energy Policy Act 2005 » Proposed Project: Plains & Eastern Clean Line Proposed Project: Plains & Eastern Clean Line On June 10, 2010, the Department of Energy published in the Federal Register a Request for Proposals (RFP) for New or Upgraded Transmission Line Projects Under Section 1222 of the Energy Policy Act (EPAct) of 2005. In response, Clean Line Energy Partners, LLC submitted an application for its Plains & Eastern Clean Line project. DOE has concluded that Clean Line's proposal was responsive to the RFP, and it is currently under consideration. The proposed Plains & Eastern Clean Line project (the proposed project) would include an overhead +/- 600 kV direct current electric transmission system and associated facilities with the capacity to deliver approximately

206

Field Guide: Transmission Line Aerial Marking and Lighting  

Science Conference Proceedings (OSTI)

Electric transmission lines and wild birds must co-exist. Power lines traverse birds' flight routes, birds commonly roost on lines and poles, and birds make their nests—the largest of which weigh thousands of pounds—on transmission structures. Some avian activities can have deleterious effects on outdoor structures and transmission—for example, nests have been known to collapse and span critical clearances during storms, resulting in outages. Accordingly, it is important for ...

2013-11-22T23:59:59.000Z

207

Microsoft Word - CX-Snohomish-MurrayWoodPoles_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 1 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Joyce Vaughn Project Manager - TELP-TPP-3 Proposed Action: Snohomish-Murray No.1 structure 9/4 modification PP&A Project No.: 1990 Budget Information: Work Order 00251084, Task 03 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6: Additions or modifications to electric power transmission facilities that would not affect the environment beyond the previously developed facility area including, but not limited to, switchyard rock grounding upgrades, secondary containment projects, paving projects, seismic upgrading, tower modifications, changing insulators, replacement of poles, circuit breakers, conductors, transformers, and crossarms.

208

Electron muon scattering in the exotic Z(0)' pole  

SciTech Connect

The search for new physics in the future Internacional Linear Collider ILC, implies the existence of new particles, among them, the Z(0)' particle. In this regard, we calculate the e{sup +}+e{sup -}{yields}{mu}{sup +}+{mu}{sup -} scattering cross section near the Z(0)' pole, whitin the contex of the SU(3){sub L}xU(1){sub Y} weak model, which contains exotic leptons, quarks, and bosons (E,J,U,V) with the finality of obtain constraints in the parameters of the model.

Diaz, H.; Ravinez, O.; Romero, D.; Reyes, J. [Instituto de Fisica Universidad Nacional de Ingenieria (Peru)

2009-04-30T23:59:59.000Z

209

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers  

Science Conference Proceedings (OSTI)

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

Xu, TengFang T.

2009-05-01T23:59:59.000Z

210

Two-Pole Caustic Model for High-Energy Lightcurves of Pulsars  

E-Print Network (OSTI)

We present a new model of high-energy lightcurves from rotation powered pulsars. The key ingredient of the model is the gap region (i.e. the region where particle acceleration is taking place and high-energy photons originate) which satisfies the following assumptions: i) the gap region extends from each polar cap to the light cylinder; ii) the gap is thin and confined to the surface of last open magnetic-field lines; iii) photon emissivity is uniform within the gap region. The model lightcurves are dominated by strong peaks (either double or single) of caustic origin. Unlike in other pulsar models with caustic effects, the double peaks arise due to crossing two caustics, each of which is associated with a different magnetic pole. The generic features of the lightcurves are consistent with the observed characteristics of pulsar lightcurves: 1) the most natural (in terms of probability) shape consists of two peaks (separated by 0.4 to 0.5 in phase for large viewing angles); 2) the peaks posess well developed wings; 3) there is a bridge (inter-peak) emission component; 4) there is a non-vanishing off-pulse emission level; 5) the radio pulse occurs before the leading high-energy peak. The model is well suited for four gamma-ray pulsars - Crab, Vela, Geminga and B1951+32 - with double-peak lightcurves exhibiting the peak separation of 0.4 to 0.5 in phase. Hereby, we apply the model to the Vela pulsar. Moreover, we indicate the limitation of the model in accurate reproducing of the lightcurves with single pulses and narrowly separated (about 0.2 in phase) pulse peaks. We also discuss the optical polarization properties for the Crab pulsar in the context of the two-pole caustic model.

J. Dyks; B. Rudak

2003-03-01T23:59:59.000Z

211

Evidence of water ice near the lunar poles  

DOE Green Energy (OSTI)

Lunar Prospector epithermal neutron data were studied to evaluate the probable chemical state of enhanced hydrogen, [H], reported previously to be near both lunar poles [1,2]. Improved versions of thermal and epithermal neutron data were developed for this purpose. Most important is the improved spatial resolution obtained by using shortened integration times. A new data set was created, Epi* = [Epithermal - 0.057 x Thermal], to reduce effects of composition variations other than those due to hydrogen. The Epi* counting rates are generally low near both lunar poles and high over terrane near recent impact events such as Tycho and Jackson. However, other lunar features are also associated with high Epi* rates, which represent a wide range of terrane types that seem to have little in common. If we postulate that one property all bright Epi* features do have in common is low [H], then measured Epi* counting rates appear to be quantitatively self consistent. If we assume that [H]=O above the top 98th percentile of Epi* counting rates at 2{sup o} x 2{sup o} spatial resolution, then [H]{sub ave} = 55 ppm for latitudes equatorward of [75{sup o}]. This value is close to the average found in returned lunar soil samples, [H]{sub ave} {approx} 50 ppm [3]. Using the foregoing physical interpretation of Epi* counting rates, we find that the Epi* counts within most of the large craters poleward of {+-}70{sup o} are higher, and therefore [H] is lower, than that in neighboring inter-crater plains, as shown in Figure 1. Fourteen of these craters that have areas larger than the LP epithermal spatial resolution (55 km diameter at 30 km altitude), were singled out for study. [H] is generally found to increase with decreasing distance from the poles (hence decreasing temperature). However, quantitative estimates of the diffusivity of hydrogen at low temperature show that diffusion can not be an important factor in explaining the difference between the relatively low [H] observed within the large sunlit polar craters and the relatively high [H] in neighboring inter-crater plains. A closer look at the 'inter-crater' plains near the poles, shows that they are covered by many small craters that harbor permanent shade [4]. The temperatures within many of these craters are low enough [5] that they can disable sublimation as a viable loss process of [H{sub 2}O]. It is therefore tempting to postulate that the enhanced hydrogen within most regions of permanent shade is in the form of water molecules. This postulate is certainly viable within the bottoms of several large, permanently shaded craters near the south pole. Predicted temperatures within them [5] fall well below the 100 K temperature that is needed to stabilize water ice for aeons. The picture is different near the north pole. Here, there are relatively few permanently-shaded craters that are large enough to harbor temperatures that are sufficiently low to stabilize water ice indefinitely against sublimation [5]. Instead, the 'inter-crater' polar plains are a jumble of many permanently-shaded craters that have diameters less than 10 km [4]. Although simulations of temperatures within this class of craters show they are only marginally cold enough to indefinitely stabilize water ice [5], this terrane appears to have the highest [H]. Nevertheless, predicted temperatures are close enough to that needed to permanently stabilize [H{sub 2}O] to suggest that sublimation is indeed the process that discriminates between polar terrane that contains enhanced [H] and those that do not (see, e.g., the temperature estimates for doubly-shaded craters [6]). If correct, then an important fraction of the hydrogen near the north pole must be in the form of H{sub 2}O, which then resides within these small craters. Estimates using our improved data set of [H] within craters near the south pole remain unchanged from those derived from our previous analysis [2], [H] = 1700{+-}900 ppm. This translates to [H{sub 2}O]=1.5{+-}0.8%. If all of the enhanced hydrogen in the north is in the form of H{sub 2}O and is confin

Feldman, W. C. (William C.); Maurice, S. (Sylvestre); Lawrence, David J. (David Jeffery),; Little, R. C. (Robert C.); Lawrence, S. L. (Stefanie L.); Gasnault, O. M. (Olivier M.); Wiens, R. C. (Roger C.); Barraclough, B. L. (Bruce L.); Elphic, Richard C.,; Prettyman, T. H. (Thomas H.); Steinberg, John Tyree; Binder, A. B.

2001-01-01T23:59:59.000Z

212

Sensor, method and system of monitoring transmission lines  

SciTech Connect

An apparatus, method, and system for measuring the magnetic field produced by phase conductors in multi-phase power lines. The magnetic field measurements are used to determine the current load on the conductors. The magnetic fields are sensed by coils placed sufficiently proximate the lines to measure the voltage induced in the coils by the field without touching the lines. The x and y components of the magnetic fields are used to calculate the conductor sag, and then the sag data, along with the field strength data, can be used to calculate the current load on the line and the phase of the current. The sag calculations of this invention are independent of line voltage and line current measurements. The system applies a computerized fitter routine to measured and sampled voltages on the coils to accurately determine the values of parameters associated with the overhead phase conductors.

Syracuse, Steven J.; Clark, Roy; Halverson, Peter G.; Tesche, Frederick M.; Barlow, Charles V.

2012-10-02T23:59:59.000Z

213

Fiber Optic Cables in Overhead Transmission Corridors: A State-of-the-Art Review  

Science Conference Proceedings (OSTI)

Many electric utilities are installing high capacity fiber optic cables and wires on their high voltage lines to satisfy their own internal communication needs and to gain additional revenues by leasing excess capacity to telecommunication network providers. This report presents a review and evaluation of the state-of-the-art in using fiber optic technology in high voltage corridors.

1997-11-26T23:59:59.000Z

214

Help Line  

NLE Websites -- All DOE Office Websites (Extended Search)

Help Line Help Line Ombuds Help Line Committed to the fair and equitable treatment of all employees, contractors, and persons doing business with the Laboratory. Contact Ombuds Office (505)665-2837 Email Help Line (505) 667-9370 Fax (505) 667-3119 Map & Hours Help Line: (505) 667-9370 As an option to visiting the Ombuds office, we provide service through a telephone Help Line and email. The telephone Help Line is useful for individuals who have concerns and want advice or referral while preserving confidentiality and anonymity. Callers may remain anonymous and the Help Line does not have caller ID or other methods of identifying callers. The Help Line maintains the same level of confidentiality and neutrality as the other Ombuds services. The Ombuds Help Line is not for reporting emergencies or officially

215

EIS-0486: Plains & Eastern Clean Line Transmission Project  

Energy.gov (U.S. Department of Energy (DOE))

This EIS will evaluate the potential environmental impacts of participating with Clean Line Energy Partners LLC (Clean Line) in the proposed Plains & Eastern Project. The proposed project would include an overhead ± 600 kilovolt (kV) high voltage direct current (HVDC) electric transmission system and associated facilities with the capacity to deliver approximately 3,500 megawatts (MW) primarily from renewable energy generation facilities in the Oklahoma Panhandle region to load-serving entities in the Mid-South and Southeast via an interconnection with the Tennessee Valley Authority (TVA).

216

High Voltage Direct Current Live Line and Insulator Testing  

Science Conference Proceedings (OSTI)

This report has two main parts. The focus of the first part is on live work in overhead high-voltage direct current (HVDC) lines operating above 100 kV dc. It does not address issues related to lines for electric transport that typically operate below 60 kV dc worldwide. In addition, this first part of the report is not a detailed treatise on live work but, rather, addresses the main issues related to dc live work. More detailed information on the general topic of live work can be found in the references...

2011-12-23T23:59:59.000Z

217

Assessment of Treated Wood and Alternate Materials for Utility Distribution Poles  

Science Conference Proceedings (OSTI)

This report provides salient facts about common and potential alternative wood pole preservatives and common and potential alternative wood pole materials for use in the electrical distribution setting. Relevant organizations are also discussed. The report presents a brief history of the development and use of each preservative and pole material. It characterizes, qualifies, and quantifies (where possible) the potential impacts of shifts from common preservatives to alternative preservatives and from sou...

2010-10-11T23:59:59.000Z

218

Microsoft Word - CX-GrandCouleeDistrictWoodPoleReplacementsAccessRoadsFY13_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

KEPR-Bell-1 SUBJECT: Environmental Clearance Memorandum Todd Wehner Civil Design/Access Roads - TELF-TPP-3 James Semrau Project Manager - TEP-TPP-1 Proposed Action: Wood pole replacement, equipment landing construction, and access road improvements along various transmission lines in Bonneville Power Administration's (BPA) Grand Coulee District. PP&A Project No.: 2152 (Grand Coulee-Chief Joseph No. 1), 2151 (Grand Coulee-Chief Joseph No. 2), 2121 (Grand Coulee-Foster Creek No. 1) and 1776 (Grand Coulee-Okanogan No. 2) Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Location: Douglas and Okanogan counties, Washington. Refer to table below for project locations: Line Name Structure Township Range Section County

219

An Examination of Temporal Trends in Electricity Reliability Based on Reports from U.S. Electric Utilities  

E-Print Network (OSTI)

and distribution lines are overhead versus underground), andand distribution lines are overhead versus underground), and

Eto, Joseph H.

2013-01-01T23:59:59.000Z

220

Evaluation of Heat Stress and Strain in Electric Utility Workers  

E-Print Network (OSTI)

inside vaults or on overhead lines. Their typical activitiestogether or to overhead transmission lines. Installing watt-

Brown, Eric Nicholas

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Application of Dixon resultant to satellite trajectory control by pole placement  

Science Conference Proceedings (OSTI)

Control system design process based on pole placement frequently requires to solve underdetermined multivariate polynomial systems. Since only the real solutions can be accepted for hardware implementation, we are looking for exclusively these roots. ... Keywords: Dixon resultant, Multivariate polynomial system, Pole placement, Satellite control, Symbolic-numeric computation

B. PaláNcz

2013-03-01T23:59:59.000Z

222

Creosote-Treated Wood Poles and Crossarms: Toxicity Characteristic Leaching Procedure (TCLP) Results  

Science Conference Proceedings (OSTI)

If creosote-treated wood poles and crossarms are classified as hazardous waste by the EPA's revised toxicity characteristic rule, disposal costs will rise dramatically. However, when the rule is applied to data obtained from this EPRI study, creosote-treated utility wood poles and crossarms receive a nonhazardous classification.

1992-08-06T23:59:59.000Z

223

Pentachlorophenol (PCP)-Treated Wood Poles and Crossarms: Toxicity Characteristic Leaching Procedure (TCLP) Results  

Science Conference Proceedings (OSTI)

If pentachlorophenol (PCP)-treated wood poles and crossarms are classified as hazardous waste by the revised toxicity characteristic (TC) rule, disposal costs will rise dramatically. However, when the ruling is applied to data obtained during this study, PCP-treated utility wood poles and crossarms receive a nonhazardous classification.

1991-01-03T23:59:59.000Z

224

Pioneering the New Grid: Pole-mounted Solar | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pioneering the New Grid: Pole-mounted Solar Pioneering the New Grid: Pole-mounted Solar Pioneering the New Grid: Pole-mounted Solar May 7, 2010 - 10:54am Addthis SunWave solar power systems are attached to utility poles, where they can gather sun power as well as provide a point of data gathering for utility companies to monitor the grid. | Photo courtesy Petra Solar SunWave solar power systems are attached to utility poles, where they can gather sun power as well as provide a point of data gathering for utility companies to monitor the grid. | Photo courtesy Petra Solar Joshua DeLung What does this mean for me? About 25,000 SunWave panels -- which generate energy for the grid as well as communicate an energy snapshot at that point -- are already in operation, with a further expected 200,000 installations.

225

Pioneering the New Grid: Pole-mounted Solar | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pioneering the New Grid: Pole-mounted Solar Pioneering the New Grid: Pole-mounted Solar Pioneering the New Grid: Pole-mounted Solar May 7, 2010 - 10:54am Addthis SunWave solar power systems are attached to utility poles, where they can gather sun power as well as provide a point of data gathering for utility companies to monitor the grid. | Photo courtesy Petra Solar SunWave solar power systems are attached to utility poles, where they can gather sun power as well as provide a point of data gathering for utility companies to monitor the grid. | Photo courtesy Petra Solar Joshua DeLung What does this mean for me? About 25,000 SunWave panels -- which generate energy for the grid as well as communicate an energy snapshot at that point -- are already in operation, with a further expected 200,000 installations.

226

Transmission Line Protection Support Tools: Fault Location Algorithms and the Potential of Using Intelligent Electronic Device Data for Protection Applications  

Science Conference Proceedings (OSTI)

Overhead transmission lines experience short-circuit faults due to lightning, stormy weather conditions, animal or tree contact, and insulation failure in power system equipment. To ensure continuity of electric service, utilities try to quickly determine the location of the fault, perform maintenance or repair, and return the line to service. Due to advances in modern technology, locating faults in a networked transmission system is now possible with substantial accuracy. Voltage and current ...

2013-12-23T23:59:59.000Z

227

Determination of High-Frequency Current Distribution Using EMTP-Based Transmission Line Models with Resulting Radiated Electromagnetic Fields  

SciTech Connect

Application of BPL technologies to existing overhead high-voltage power lines would benefit greatly from improved simulation tools capable of predicting performance - such as the electromagnetic fields radiated from such lines. Existing EMTP-based frequency-dependent line models are attractive since their parameters are derived from physical design dimensions which are easily obtained. However, to calculate the radiated electromagnetic fields, detailed current distributions need to be determined. This paper presents a method of using EMTP line models to determine the current distribution on the lines, as well as a technique for using these current distributions to determine the radiated electromagnetic fields.

Mork, B; Nelson, R; Kirkendall, B; Stenvig, N

2009-11-30T23:59:59.000Z

228

Cosmic String constraints from WMAP and the South Pole Telescope  

E-Print Network (OSTI)

The predictions of the inflationary LCDM paradigm match today's high-precision measurements of the cosmic microwave background anisotropy extremely well. The same data put tight limits on other sources of anisotropy. Cosmic strings are a particularly interesting alternate source to constrain. Strings are topological defects, remnants of inflationary-era physics that persist after the big bang. They are formed in a variety of models of inflation, including string theory models such as brane inflation. We assume a "Nambu-Goto" model for strings, approximated by a collection of unconnected segments with zero width, and show that measurements of temperature anisotropy by the South Pole Telescope break a parameter degeneracy in the WMAP data, permitting us to place a strong upper limit on the possible string contribution to the CMB anisotropy: the power sourced by zero-width strings must be <1.75% (95% CL) of the total or the string tension Gmu <1.7x10^{-7}. These limits imply that the best hope for detecting strings in the CMB will come from B-mode polarization measurements at arcminute scales rather than the degree scale measurements pursued for gravitational wave detection.

Cora Dvorkin; Mark Wyman; Wayne Hu

2011-09-22T23:59:59.000Z

229

line, Pinal County, Arizona RECORD OF CATEGORICAL EXCLUSION DETERMINATION  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

along the existing along the existing Empire-EDS 11S-kV transmission line, Pinal County, Arizona RECORD OF CATEGORICAL EXCLUSION DETERMINATION A. Proposed Action: Western proposes to replace structures and upgrade to a double circuit 230-kV transmission line on its Empire-ED5 115-kV transmission line, within Western's existing right-of-way. This will include the rebuild of 9.2 miles of transmission line, replacing the H-frame structures with steel monopole structures with foundations, hardware and insulator replacement and adding a overhead ground-wire over the entire length of the project. Western will access the structure using crew trucks along the existing access roads. This work is necessary to maintain the safety and reliability of the bulk electrical system.

230

Microtubule tethers at kinetochores and spindle poles : essential mitotic components  

E-Print Network (OSTI)

cells. Mol Biol Cell 14, Lewandoski, M. , Wassarman, K. M. ,458. Meyers, E. N. , Lewandoski, M. , and Martin, G. R. (in the female germ line (Lewandoski et al. , 1997) produced

Silk, Alain Daniel

2008-01-01T23:59:59.000Z

231

Sidney-North Yuma 230-kV Transmission Line Project, Colorado and Nebraska  

SciTech Connect

This report describes the need for a 230-kV overhead transmission line to supply power from Sidney, Nebraska to eastern Colorado. The alternative scenario compared to construction of the line is No Action. Rejected alternatives include underground lines and different routing paths, with a possible extension to the Sterling area. Both scenarios are evaluated for environmental effects, cost, and consequences for the eastern Colorado region. The proposed route is determined to be the environmentally preferred choice. 120 refs., 6 figs., 13 tabs. (MHB)

1991-06-01T23:59:59.000Z

232

Old Y-12 utility poles put to use for recreation and training | National  

National Nuclear Security Administration (NNSA)

Old Y-12 utility poles put to use for recreation and training | National Old Y-12 utility poles put to use for recreation and training | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Old Y-12 utility poles put to use ... Old Y-12 utility poles put to use for recreation and training Posted By Office of Public Affairs Logs and trucks Maintenance Support and Utilities Management personnel at NNSA's Y-12

233

Radiosonde Observations from the Former Soviet “North Pole” Series of Drifting Ice Stations, 1954–90  

Science Conference Proceedings (OSTI)

An historical archive of over 25 000 radiosonde observations from the former Soviet "North Pole" series of drifting ice stations has been compiled and made available to interested researchers. This archive is the only long-term set of ...

Jonathan D. W. Kahl; Nina A. Zaitseva; V. Khattatov; R. C. Schnell; Dina M. Bacon; Jason Bacon; V. Radionov; M. C. Serreze

1999-10-01T23:59:59.000Z

234

Geek-Up[12.23.2010]: Muons at the South Pole and Dr. Nick Holoynak |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2.23.2010]: Muons at the South Pole and Dr. Nick Holoynak 2.23.2010]: Muons at the South Pole and Dr. Nick Holoynak Geek-Up[12.23.2010]: Muons at the South Pole and Dr. Nick Holoynak December 23, 2010 - 12:05pm Addthis Illustration of the IceCube neutrino observatory. Source: LBNL Illustration of the IceCube neutrino observatory. Source: LBNL Niketa Kumar Niketa Kumar Public Affairs Specialist, Office of Public Affairs Earlier today, the Energy Blog featured Los Alamos National Lab's system to track Santa. However, while there is a lot of attention focused on the North Pole right now, the Geek-Up[date] team is taking a look at the opposite end of the Earth. This past weekend, a collaborative group of 40 institutions from around the world, including DOE's Lawrence Berkeley National Lab, celebrated the completion of the IceCube Neutrino Observatory

235

Recent Interannual Variations in Solar Radiation, Cloudiness, and Surface Temperature at the South Pole  

Science Conference Proceedings (OSTI)

Incoming global solar irradiance measured at the surface at the South Pole unexpectedly decreased steadily by 15% from 1976 through 1987 during the late austral summer season, whereas no trend is apparent for September through December. February'...

Ellsworth G. Dutton; Robert S. Stone; Donald W. Nelson; Bernard G. Mendonca

1991-08-01T23:59:59.000Z

236

Lidar Determinations of Atmospheric Ice Crystal Layers at South Pole during Clear-Sky Precipitation  

Science Conference Proceedings (OSTI)

Results of lidar measurements of atmospheric ice crystal layers during 36 clear-sky precipitation events at South Pole (2850 m MSL) during the winter over the period March-November 1975 are presented and correlated with ice crystal replicator, ...

Vern N. Smiley; Bruce M. Whitcomb; Bruce M. Morley; Joseph A. Warburton

1980-09-01T23:59:59.000Z

237

Old Y-12 utility poles put to use for recreation and training...  

NLE Websites -- All DOE Office Websites (Extended Search)

trucks Maintenance Support and Utilities Management personnel at NNSA's Y-12 National Security Complex have taken steps to make sure old utility poles aren't sent to the...

238

Soliton Solutions with Real Poles in the Alekseev formulation of the Inverse-Scattering method  

E-Print Network (OSTI)

A new approach to the inverse-scattering technique of Alekseev is presented which permits real-pole soliton solutions of the Ernst equations to be considered. This is achieved by adopting distinct real poles in the scattering matrix and its inverse. For the case in which the electromagnetic field vanishes, some explicit solutions are given using a Minkowski seed metric. The relation with the corresponding soliton solutions that can be constructed using the Belinskii-Zakharov inverse-scattering technique is determined.

S. Micciche; J. B. Griffiths

1999-09-22T23:59:59.000Z

239

Options for Prevention, Mitigation, and Remediation at Wood Poles Storage Sites  

Science Conference Proceedings (OSTI)

As part of the maintenance of the electrical transmission and distribution networks in the United States, electric utilities store treated wood poles and cross arms at storage facilities. During this storage, chemicals of concern (COCs) used in preservative formulations can drip and leach during precipitation events from the treated wood poles and cross arms, potentially impacting site soils, groundwater, and nearby surface water bodies. These COCs will vary depending on the types of treated wood stored ...

2006-03-06T23:59:59.000Z

240

Managing Transmission Line Wood Structures  

Science Conference Proceedings (OSTI)

The objective of this project is to reduce capital cost by extending life expectancy of overhead transmission wood structures through inspection and assessment procedures and through aging mitigation techniques and tools.

2005-11-29T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

CHAPTER III OVERHEAD ORGANIZATION  

Science Conference Proceedings (OSTI)

... These positions frequently pay well and are political sinecures, eagerly ... of the personnel from political domination, the stimulation of applications ...

2010-03-19T23:59:59.000Z

242

Overhead Conductor Management Guide  

Science Conference Proceedings (OSTI)

As transmission systems age, utilities are increasingly concerned about the reliability of aging conductors, especially ACSR conductors, which cannot be assessed visually because of the layers of aluminum strand that cover their cores. Utilities wishing to determine how much core strength remains in these conductors can only do so by sampling the conductor and subsequently subjecting it to tensile testing or by looking at the significant circuits that pose a reliability risk using the Cormon Device or El...

2010-12-23T23:59:59.000Z

243

EA-1679: Grand Coulee's Third Powerplant 500-kV Transmission Line  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

79: Grand Coulee's Third Powerplant 500-kV Transmission Line 79: Grand Coulee's Third Powerplant 500-kV Transmission Line Replacement Project, Grant and Okanogon Counties, Washington EA-1679: Grand Coulee's Third Powerplant 500-kV Transmission Line Replacement Project, Grant and Okanogon Counties, Washington Summary This EA evaluates potential environmental impacts from the construction and operation of six new 500-kV overhead transmission lines to replace six existing underground lines at Grand Coulee Dam. DOE's Bonneville Power Administration (BPA), a cooperating agency, was asked by the U. S. Department of the Interior's Bureau of Reclamation to design and construct the proposed new transmission lines. A Finding of No Significant Impact was issued by BPA in December 2011. BPA website: http://efw.bpa.gov/environmental_services/Document_Library/Grand_Coulee/

244

EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project,  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3: Estes to Flatiron Substation Transmission Lines Rebuild 3: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO SUMMARY DOE's Western Area Power Administration (Western) owns and operates two 16-mile, 115-kilovolt transmission lines on separate rights-of-way between Flatiron Reservoir (near Loveland, Colorado) and the town of Estes Park, Colorado. Western is preparing this EIS to evaluate the environmental impacts of a proposal to upgrade and co-locate these transmission lines, by removing one and abandoning its right-of-way, and rebuilding the other along the existing right-of-way as a double-circuit line (i.e., six conductors per pole). The USDA Forest Service, Arapaho and Roosevelt National Forest, is a cooperating agency in preparing the EIS to support

245

BEAM LINE  

NLE Websites -- All DOE Office Websites (Extended Search)

BEAM LINE BEAM LINE 45 W ILHELM ROENTGEN'S INITIAL DISCOVERY of X-radiation in 1895 led immediately to practical applications in medicine. Over the next few decades X rays proved to be an invaluable tool for the investigation of the micro-world of the atom and the development of the quantum theory of matter. Almost a century later, telescopes designed to detect X-radiation are indispensable for understanding the structure and evolution of the macro-world of stars, galaxies, and the Universe as a whole. The X-Ray Universe by WALLACE H. TUCKER X-ray images of the Universe are strikingly different from the usual visible-light images. 46 SUMMER 1995 did not think: I investigated." Undeterred by NASA's rejection of a proposal to search for cosmic X-radiation, Giacconi persuaded the

246

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network (OSTI)

Horizontal lines indicate location of overhead luminaires.horizontal lines indicate location of overhead luminaires.overhead electrical lighting was at full output. The horizontal line

Konis, Kyle Stas

2011-01-01T23:59:59.000Z

247

Aspects of the Biology and the Effects of Traditional and Non-Traditional Insecticides on Citrus Thrips and Avocado Thrips with the Objective of Improving Integrated Pest Management  

E-Print Network (OSTI)

rows where the overhead sprinkler line was turned off. Therows where the overhead sprinkler line was turned off. Thealone versus (2) drip-line with overhead sprinkler, because

Zahn, Deane K.

2011-01-01T23:59:59.000Z

248

Sierra Pacific Power Company Alturas Transmission Line Project, Final Environmental Impact Report/Environmental Impact Statement. Volume 3: Appendices  

Science Conference Proceedings (OSTI)

Sierra Pacific Power Company has proposed the construction and operation of a 345,000 volt overhead electric power transmission line from Alturas, California to Reno, Nevada. This Environmental Impact Report/Environmental Impact Statement will assess the potential environmental impacts of the proposed project and alternatives. This report contains Appendices A--I which contain the following: glossary/abbreviations; scoping report; structure coordinate summary; air quality; biological resources; geology; noise; visual contrast rating forms; and cultural resources.

NONE

1995-11-01T23:59:59.000Z

249

Pilot Study for the Replication of the Draper Study of Leukemia, Brain Tumors, and Distance to Power Lines in California  

Science Conference Proceedings (OSTI)

In 2005, a study in the United Kingdom, referred to in this report as the Draper study, reported a positive association between residential proximity to overhead transmission lines and childhood leukemia. This report describes a pilot study that was performed to determine the feasibility of replicating this study in California. The purpose of this pilot study was to identify potential difficulties with performing this type of an evaluation in California and to design a rigorous and cost-effective methodo...

2008-02-28T23:59:59.000Z

250

Prospective Outlook on Long-Term Energy Systems (POLES) | Open Energy  

Open Energy Info (EERE)

Prospective Outlook on Long-Term Energy Systems (POLES) Prospective Outlook on Long-Term Energy Systems (POLES) Jump to: navigation, search LEDSGP green logo.png FIND MORE DIA TOOLS This tool is part of the Development Impacts Assessment (DIA) Toolkit from the LEDS Global Partnership. Tool Summary LAUNCH TOOL Name: Prospective Outlook on Long-Term Energy Systems (POLES) Agency/Company /Organization: European Commission, Enerdata, in collaboration with LEPII Sector: Climate, Energy Focus Area: Renewable Energy, Greenhouse Gas Topics: Low emission development planning Resource Type: Software/modeling tools Complexity/Ease of Use: Advanced Website: www.enerdata.net/docssales/press-office-20th-world-energy-congress.pdf Cost: Free Related Tools Modular Applied General Equilibrium Tool (MAGNET) WorldScan SEAGA Intermediate Level Handbook

251

Instrument for analysis of electric motors based on slip-poles component  

DOE Patents (OSTI)

A new instrument for monitoring the condition and speed of an operating electric motor from a remote location. The slip-poles component is derived from a motor current signal. The magnitude of the slip-poles component provides the basis for a motor condition monitor, while the frequency of the slip-poles component provides the basis for a motor speed monitor. The result is a simple-to-understand motor health monitor in an easy-to-use package. Straightforward indications of motor speed, motor running current, motor condition (e.g., rotor bar condition) and synthesized motor sound (audible indication of motor condition) are provided. With the device, a relatively untrained worker can diagnose electric motors in the field without requiring the presence of a trained engineer or technician.

Haynes, Howard D. (Knoxville, TN); Ayers, Curtis W. (Clinton, TN); Casada, Donald A. (Knoxville, TN)

1996-01-01T23:59:59.000Z

252

Instrument for analysis of electric motors based on slip-poles component  

DOE Patents (OSTI)

A new instrument is described for monitoring the condition and speed of an operating electric motor from a remote location. The slip-poles component is derived from a motor current signal. The magnitude of the slip-poles component provides the basis for a motor condition monitor, while the frequency of the slip-poles component provides the basis for a motor speed monitor. The result is a simple-to-understand motor health monitor in an easy-to-use package. Straightforward indications of motor speed, motor running current, motor condition (e.g., rotor bar condition) and synthesized motor sound (audible indication of motor condition) are provided. With the device, a relatively untrained worker can diagnose electric motors in the field without requiring the presence of a trained engineer or technician. 4 figs.

Haynes, H.D.; Ayers, C.W.; Casada, D.A.

1996-11-26T23:59:59.000Z

253

Microsoft Word - CX-VeraTap_WoodPoles_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

10, 2011 10, 2011 REPLY TO ATTN OF: KEPR-Bell-1 SUBJECT: Environmental Clearance Memorandum Erich Orth Project Manager - TEP-TPP-3 Proposed Action: Modify two structures along the Vera Tap to Trentwood-Valley Way #1, 115-kV transmission line PP&A Project No: 1669 Work Order No: 259751 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021):  B1.3 Routine maintenance activities...for structures, rights of way, infrastructures such as roads, equipment...routine maintenance activities, corrective....are required to maintain...infrastructures...in a condition suitable for a facility to be used for its designed purpose.  B4.6 Additions or modifications to electric power transmission facilities that would not affect the environment beyond the previously developed facility area

254

Microsoft Word - CX-WhiteBluffs_pole_work_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

August 9, 2010 August 9, 2010 REPLY TO ATTN OF: KEP-4 SUBJECT: Environmental Clearance Memorandum Alan Kjosness Civil Engineering Technician - TELP-TPP-3 Proposed Action: Swapping substation bay terminals of Bonneville Power Administration's (BPA) White Bluffs-Richland #1 and DOE B3-S4-White Bluffs #1 transmission lines Budget Information: Work Order # 242562 and 242567 PP&A Project No.: PP&A 1331 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3, Routine maintenance activities...for structures, rights-of-way, infrastructures such as roads, equipment...routine maintenance activities, corrective....are required to maintain... infrastructures... in a condition suitable for a facility to be used for its designed purpose.

255

Differences Between the Pole and On-Shell Masses and Widths of the Higgs Boson  

E-Print Network (OSTI)

The differences between the on-shell mass and width of the Higgs boson and their pole counterparts are evaluated in leading order. For a heavy Higgs boson, they are found to be sensitive functions of the gauge parameter and become numerically large over a class of gauges that includes the unitary gauge. For a light Higgs boson, the differences remain small in all gauges. The pinch-technique mass and width are found to be close to their pole counterparts over a large range of Higgs boson masses.

B. A. Kniehl; A. Sirlin

1998-05-20T23:59:59.000Z

256

Microsoft Word - CX-AlveyMaintenanceHQ_PoleStorageUpgrade_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4 4 SUBJECT: Environmental Clearance Memorandum Brett Sherer Project Manager - KEP-4 Proposed Action: Environmental protection system upgrades at pole storage facility at Alvey Maintenance Headquarters. Budget Information: Work Order #00283226 Categorical Exclusion Applied (Appendix B to Subpart D, 10 C.F.R. Part 1021): B4.6: Additions or modifications to electric power transmission facilities that would not affect the environment beyond the previously developed facility area including, but not limited to, switchyard rock grounding upgrades, secondary containment projects, paving projects, seismic upgrading, tower modifications, changing insulators, and replacement of poles, circuit breakers, conductors, transformers, and crossarms.

257

DOE/EA-1967: Hills Creek-Lookout Point Transmission Line Rebuild, Lane County, Oregon  

Energy.gov (U.S. Department of Energy (DOE))

Bonneville Power Administration is preparing an EA to assess potential environmental impacts of the proposed rebuild of its 26-mile 115 kilovolt (kV) wood-pole Hills Creek-Lookout Point transmission line, which is generally located between Lowell and Oakridge, in Lane County, Oregon.

258

EA-1961: Kalispell-Kerr Transmission Line Rebuild Project, Kalispell and Polson, Montana  

Energy.gov (U.S. Department of Energy (DOE))

Bonneville Power Administration is preparing an EA to evaluate potential environmental impacts of rebuilding its 41-mile long 115 kilovolt (kV) wood-pole Kalispell-Kerr transmission line between Kalispell and Polson, Montana. Additional information is available on the project website, http://efw.bpa.gov/environmental_services/Document_Library/KALISPELL_KERR/.

259

EIS-0486: Plains & Eastern Clean Line Transmission Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

86: Plains & Eastern Clean Line Transmission Project 86: Plains & Eastern Clean Line Transmission Project EIS-0486: Plains & Eastern Clean Line Transmission Project SUMMARY This EIS will evaluate the potential environmental impacts of participating with Clean Line Energy Partners LLC (Clean Line) in the proposed Plains & Eastern Project. The proposed project would include an overhead ± 600 kilovolt (kV) high voltage direct current (HVDC) electric transmission system and associated facilities with the capacity to deliver approximately 3,500 megawatts (MW) primarily from renewable energy generation facilities in the Oklahoma Panhandle region to load-serving entities in the Mid-South and Southeast via an interconnection with the Tennessee Valley Authority (TVA). PUBLIC COMMENT OPPORTUNITIES None available at this time.

260

Modeling and experimental validation of internal faults in salient pole synchronous machines including space harmonics  

Science Conference Proceedings (OSTI)

Considering the space harmonics caused by the faulted windings, a simulation model of internal faults in salient pole synchronous machines is proposed in this paper. The model is based on the winding function approach, which makes no assumption for sinusoidal ... Keywords: Internal faults, Space harmonics, Synchronous machines, Winding function

X. Tu; L. -A. Dessaint; M. El Kahel; A. Barry

2006-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Intercepts and residues of Regge poles in a stochastic-field multiparticle theory  

SciTech Connect

A dynamical theory of multiparticle amplitudes, based on a functional integral representation embodying collective long-range correlations, is applied to the calculation of Regge intercepts and residues. Poles arising in conventional multiperipheral models will characteristically be modified in three ways: promotion, renormalization, and a proliferation of dynamical secondary trajectories, reminiscent of dual models. (auth)

Arnold, R.C.

1976-01-01T23:59:59.000Z

262

Application of ring lasers to determine the directions to the poles of Earth's rotation  

Science Conference Proceedings (OSTI)

Application of a ring laser to determine the directions to the poles of Earth's rotation is considered. The maximum accuracy of determining the directions is calculated, physical and technical mechanisms that limit the accuracy are analysed, and the instrumental errors are estimated by the example of ring He - Ne lasers with Zeeman biasing. (laser applications and other topics in quantum electronics)

Golyaev, Yu D; Kolbas, Yu Yu [Open Joint-Stock Company 'M.F. Stel'makh Polyus Research and Development Institute', Moscow (Russian Federation)

2012-10-31T23:59:59.000Z

263

Testing and Analysis of the Single-Phase Written-Pole Motor  

Science Conference Proceedings (OSTI)

The Written-Pole Motor (WPM) is a new development in the area of electrical machines that have been designed for relatively high powers from a low-voltage, single-phase supply. A 20-hp WPM has been tested in the laboratory to confirm the manufacturer's performance claims.

1998-12-31T23:59:59.000Z

264

Pole-Zero Placement Technique Based Hydro Turbine Speed Governor Design  

Science Conference Proceedings (OSTI)

According to different structure of hydraulic systems combined with hydro-turbine for hydropower plant, the 5order nonlinear control model of hydro turbine speed governor system for hydraulic system which composed of reservoir-tunnel-surge-penstock-generator ... Keywords: Hydro turbine speed governor system, pole-zero placement, Nonlinear control, PID

Fan-Nie Kong; Xiao-Cong Li

2012-04-01T23:59:59.000Z

265

Creosote-treated wood poles and crossarms: Toxicity Characteristic Leaching Procedure (TCLP) results  

Science Conference Proceedings (OSTI)

The objective of this study was to develop a quantitative database on leachable concentrations of cresols (i.e., m-, o- and p-cresol isomers) from a population of creosote-treated utility wood poles and crossarms by application of the Toxicity Characteristic Leaching Procedure (TCLP). The TCLP was promulgated by the US Environmental Protection Agency (EPA) in March 1990 (55FR 11798). Data generated in this study indicate that creosote-treated utility poles and crossarms are non-hazardous. Measured concentrations of total cresols and other semi-volatile organic compounds, from wood subjected to TCLP analysis, were an order of magnitude or more below their current Toxicity Characteristic (TC) regulatory levels. The wood analyzed in this study consisted of 54 samples of wood poles and 6 crossarms. Subsamples, removed from full cross sectional slices of poles and crossarms, were prepared according to EPA procedures, subjected to the TCLP, and the resultant leachates analyzed for the presence of cresols and other semi-volatile compounds.

Horn, M.E. (Environmental Management Services, Waupaca, WI (United States)); Holcombe, L.; Owens, J.B. (Radian Corp., Austin, TX (United States))

1992-07-01T23:59:59.000Z

266

Microphysical and Optical Properties of Atmospheric Ice Crystals at South Pole Station  

Science Conference Proceedings (OSTI)

In early February 2001 (during the austral summer), over 900 000 digital images of ice crystals were recorded at the South Pole using two ground-based cloud particle imagers (CPIs). Of these, 721 572 crystals >50 ?m were classified into crystal ...

R. Paul Lawson; Brad A. Baker; Patrick Zmarzly; Darren O’Connor; Qixu Mo; Jean-Francois Gayet; Valery Shcherbakov

2006-11-01T23:59:59.000Z

267

Measurements of Secodary Cosmic Microwave Background Anisotropies with the South Pole Telescope  

E-Print Network (OSTI)

Measuring L SQ . . . . . . . . 4.3 Transmission lines: 4K tolike system. . . . Transmission line resonances in the 4Kpoorly matched to the transmission lines connecting them to

Lueker, Martin Van

2010-01-01T23:59:59.000Z

268

Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska  

SciTech Connect

The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA).

NONE

1995-05-01T23:59:59.000Z

269

Power Line-Induced AC Potential on Natural Gas Pipelines for Complex Rights-of-Way Configurations, Volume 1: Engineering Analysis  

Science Conference Proceedings (OSTI)

This report addresses complex common corridor coupling problems for overhead electric power transmission lines and buried natural gas pipelines. Volume 1 describes the development of analytic methods for solving such problems and presents field data used in verification efforts. Volume 2 is a handbook for graphic analysis designed for use by field personnel or others without access to a computer. Volume 3 is a user's guide for the PIPELINE computer code.

1983-05-01T23:59:59.000Z

270

Sierra Pacific Power Company Alturas Transmission Line Project, Final Environmental Impact Report/Environmental Impact Statement. Volume 2: Comments and responses  

Science Conference Proceedings (OSTI)

Sierra Pacific Power Company has proposed the construction and operation of a 345,000 volt overhead electric power transmission line from Alturas, California to Reno, Nevada. This Environmental Impact Report/Environmental Impact Statement will assess the potential environmental impacts of the proposed project and alternatives. This report contains public comments which were received on the Draft EIR/S. Significant issues may be identified through public and agency comments.

NONE

1995-11-01T23:59:59.000Z

271

South Pole Telescope helps Argonne scientists study earliest ages of the  

NLE Websites -- All DOE Office Websites (Extended Search)

Related Content Related Content Employee Spotlight: Clarence Chang South Pole Telescope helps Argonne scientists study earliest ages of the universe By Louise Lerner * October 28, 2013 Tweet EmailPrint For physicist Clarence Chang at the U.S. Department of Energy's (DOE) Argonne National Laboratory, looking backward in time to the earliest ages of the universe is all in a day's work. Chang helped design and operate part of the South Pole Telescope, a project that aims a giant telescope at the night sky to track tiny bits of radiation that are still traveling across the universe from the period just after it was born. "Basically, what we're looking at is the afterglow light of the Big Bang," Chang said. In the wake of the Big Bang, all the matter in the universe was just hot,

272

Microsoft Word - CX-FY10_Ross-VanShip_Wood_Pole_Replacement_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Clearance Memorandum Clearance Memorandum Troy Dalrymple Lineman Foreman I - TFVK-LMT Proposed Action: Wood pole replacement of Ross-Vancouver Shipyard No. 1, Structure 2/3 in Fog Chamber Dump Area #2 PP&A Project No: 1721 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance activities...for structures, rights-of-way, infrastructures such as roads, equipment... routine maintenance activities, corrective....are required to maintain...infrastructures...in a condition suitable for a facility to be used for its designed purpose. Location: Ross Complex, Vancouver, WA. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace deteriorating wood poles and associated structural/electrical components (e.g. cross arms, insulators, guy anchors) on

273

Financing, Overhead, and Profit: An In-Depth Discussion of Costs Associated with Third-Party Financing of Residential and Commercial Photovoltaic Systems  

SciTech Connect

Previous work quantifying the non-hardware balance-of-system costs -- or soft costs -- associated with building a residential or commercial photovoltaic (PV) system has left a significant portion unsegmented in an 'other soft costs' category. This report attempts to better quantify the 'other soft costs' by focusing on the financing, overhead, and profit of residential and commercial PV installations for a specific business model. This report presents results from a bottom-up data-collection and analysis of the upfront costs associated with developing, constructing, and arranging third-party-financed residential and commercial PV systems. It quantifies the indirect corporate costs required to install distributed PV systems as well as the transactional costs associated with arranging third-party financing.

Feldman, D.; Friedman, B.; Margolis, R.

2013-10-01T23:59:59.000Z

274

Bound, virtual, and resonance S-matrix poles from the Schroedinger equation  

SciTech Connect

A general method, which we call the potential S-matrix pole method, is developed for obtaining the S-matrix pole parameters for bound, virtual, and resonant states based on numerical solutions of the Schroedinger equation. This method is well known for bound states. In this work we generalize it for resonant and virtual states, although the corresponding solutions increase exponentially when r->infinity. Concrete calculations are performed for the 1{sup +} ground state of {sup 14}N, the resonance {sup 15}F states (1/2{sup +}, 5/2{sup +}), low-lying states of {sup 11}Be and {sup 11}N, and the subthreshold resonance in the proton-proton system. We also demonstrate that in the case of broad resonances, their energy and width can be found from the fitting the experimental phase shifts using the analytical expression for the elastic-scattering S matrix. We compare the S-matrix pole and the R matrix methods for broad resonances in the {sup 14}O-p and in {sup 26}Mg-n systems.

Mukhamedzhanov, A. M.; Goldberg, V. Z. [Cyclotron Institute, Texas A and M University, College Station, Texas 77843 (United States); Irgaziev, B. F.; Qazi, I. [GIK Institute of Engineering Sciences and Technology, Topi (Pakistan); Orlov, Yu. V. [Institute of Nuclear Physics, Moscow State University, Moscow (Russian Federation)

2010-05-15T23:59:59.000Z

275

Whitney Poling  

Science Conference Proceedings (OSTI)

... Mechanical Metallurgy, Failure of metals and characterization of fracture surfaces, Quartz Crystal Microbalance, Electron Microscopy ...

2012-10-01T23:59:59.000Z

276

Elimination of PZT thin film breakage caused by electric current arcing and intrinsic differential strains during poling  

E-Print Network (OSTI)

Historically, substrate breakage during the poling process has been responsible for a 2% yield loss for a contract manufacturer specializing in volume production of lead zirconate titatate (PZT) thin film devices. In this ...

AlSaeed, Abdulelah (Abdulelah Ibrahim)

2012-01-01T23:59:59.000Z

277

Utilizing the connected power electronic converter for improved condition monitoring of induction motors and claw-pole generators.  

E-Print Network (OSTI)

??This dissertation proposes several simple, robust, and non-intrusive condition monitoring methods for induction motors fed by closed-loop inverters and claw-pole generators with built-in rectifiers. While… (more)

Cheng, Siwei

2012-01-01T23:59:59.000Z

278

A Comparison of Meteorological Observations from South Pole Station before and after Installation of a New Instrument Suite  

Science Conference Proceedings (OSTI)

The Amundsen–Scott South Pole surface meteorological instrument suite was upgraded in 2004. To ensure that the new and old instruments were recording similar information, the two suites of instruments ran simultaneously for a year. Statistical ...

L. M. Keller; K. A. Baker; M. A. Lazzara; J. Gallagher

2009-08-01T23:59:59.000Z

279

Discrete-Time Poles and Dynamics of Discontinuous Mode Boost and Buck Converters Under Various Control Schemes  

E-Print Network (OSTI)

Nonlinear systems, such as switching DC-DC boost or buck converters, have rich dynamics. A simple one-dimensional discrete-time model is used to analyze the boost or buck converter in discontinuous conduction mode. Seven different control schemes (open-loop power stage, voltage mode control, current mode control, constant power load, constant current load, constant-on-time control, and boundary conduction mode) are analyzed systematically. The linearized dynamics is obtained simply by taking partial derivatives with respect to dynamic variables. In the discrete-time model, there is only a single pole and no zero. The single closed-loop pole is a linear combination of three terms: the open-loop pole, a term due to the control scheme, and a term due to the non-resistive load. Even with a single pole, the phase response of the discrete-time model can go beyond -90 degrees as in the two-pole average models. In the boost converter with a resistive load under current mode control, adding the compensating ramp has no effect on the pole location. Increasing the ramp slope decreases the DC gain of control-to-output transfer function and increases the audio-susceptibility. Similar analysis is applied to the buck converter with a non-resistive load or variable switching frequency. The derived dynamics agrees closely with the exact switching model and the past research results.

Chung-Chieh Fang

2012-11-19T23:59:59.000Z

280

Best Practices in the Control Center  

Science Conference Proceedings (OSTI)

In this EPRI Whitepaper, CenterPoint Energy Inc. and EPRI personnel discuss the cyber security practices developed and deployed at CenterPoint's control center over the last decade. Founded in 1882, CenterPoint Energy Inc. owns 27,603 pole miles of overhead distribution lines and 3,727 circuit miles of overhead transmission lines, 19,690 circuit miles of underground distribution lines, 26 circuit miles of underground transmission lines, and 229 substation sites with a capacity of 51,400 megavolt amperes ...

2009-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Transmission of a quantum state in a periodically poled nonlinear crystal  

E-Print Network (OSTI)

Theoretical calculations on transmission of quantum states such as Schr\\"{o}dinger cat (SC) states are considered in a periodically poled nonlinear crystal (PPNC). Combinations of various initial states (SC, coherent (C),and vacuum (V)) of light waves at frequencies $\\omega_{e}$ and $3\\omega_{e}$ at the input of a PPNC are studied. It is shown that the transmission and interference between superposition of macroscopically distinguishable states can be achieved by using a PPNC. Visualization and analyzes of transmission and interference processes are demonstrated with the help of reduced Wigner quasi-probability distribution functions of considered light waves.

Ranjit Singh

2010-05-03T23:59:59.000Z

282

Image Gallery from the AMANDA Experiment, the Predecessor of IceCube at the South Pole  

DOE Data Explorer (OSTI)

IceCube is a neutrino observatory for astrophysics, with parts buried below the surface of the ice at the South Pole and an air-shower detector array exposed above. Its predecessor detector and experiment, AMANDA, pioneered neutrino detection in ice. This image gallery is maintained at the University of Wisconsin. Also provided are links to related galleries concerning construction of optical modules, ice coring and drilling, and the U.S. Antarctic Program Photo Library. See also the library of videos, computer animations, and audio files

Abbasi, R. et al

283

Polarimeter Receiver Prototyping and Testing for the South Pole Telescope Upgrade  

E-Print Network (OSTI)

Experimental evidence has so far been supportive for the inflationary Big Bang model of cosmology, while imposing other mysteries, such as the fact that dark matter and dark energy actually consist of 95 % of the observable universe. The forthcoming upgrade of the South Pole Telescope, planned for 2010, will include a polarimeter with increased sensitivity. Measurements of the CMB polarization anisotropy to a high accuracy will describe the angular power spectrum of the B-mode polarization, which will help unravel some of the mysteries. We prototype and test a digital frequency multiplexed readout system for the SPT upgrade. The digital system has the advantage of being able to reconstruct the phase of the signals. We characterize the performance of the readout and we compare it to the theoretical expectations. The noise is found to be statistically insignificant (insert quantitative proof), and the system performs as expected, significantly better than the previous implementation. We conclude that the digital fMux readout system should be sent to the South Pole Telescope. 1

Constantinos Melachrinos

2009-01-01T23:59:59.000Z

284

Mechanical design and analysis of an eight-pole superconducting vector magnet for soft x-ray magnetic dichroism measurements  

Science Conference Proceedings (OSTI)

An eight-pole superconducting magnet is being developed for soft x-ray magnetic dichroism (XMD) experiments at the Advanced Light Source, Lawrence Berkley National Laboratory (LBNL). Eight conical Nb{sub 3}Sn coils with Holmium poles are arranged in octahedral symmetry to form four dipole pairs that provide magnetic fields of up to 5 T in any direction relative to the incoming x-ray beam. The dimensions of the magnet yoke as well as pole taper, diameter, and length were optimized for maximum peak field in the magnet center using the software package TOSCA. The structural analysis of the magnet is performed using ANSYS with the coil properties derived using a numerical homogenization scheme. It is found that the use of orthotropic material properties for the coil has an important influence in the design of the magnet.

Arbelaez, D.; Black, A.; Prestemon, S.O.; Wang, S.; Chen, J.; Arenholz, E.

2010-01-13T23:59:59.000Z

285

Nuclear reactor overflow line  

DOE Patents (OSTI)

The overflow line for the reactor vessel of a liquid-metal-cooled nuclear reactor includes means for establishing and maintaining a continuous bleed flow of coolant amounting to 5 to 10% of the total coolant flow through the overflow line to prevent thermal shock to the overflow line when the reactor is restarted following a trip. Preferably a tube is disposed concentrically just inside the overflow line extending from a point just inside the reactor vessel to an overflow tank and a suction line is provided opening into the body of liquid metal in the reactor vessel and into the annulus between the overflow line and the inner tube.

Severson, Wayne J. (Pittsburgh, PA)

1976-01-01T23:59:59.000Z

286

The use of Ixaru's method in locating the poles of the S-matrix in strictly finite-range potentials  

Science Conference Proceedings (OSTI)

Energies of the S-matrix poles are calculated by solving the radial Schroedinger equation numerically by using Ixaru's CPM(2) method. The trajectories of the poles in the complex wave number plane are determined for two nuclear potentials that are zero beyond finite distances. These are the Woods-Saxon form with cutoff and the Salamon-Vertse potential, which goes to zero smoothly at a finite distance. Properties of the trajectories are analyzed for real and complex values of the depths of the corresponding potentials.

Vertse, Tamas; Lovas, R. G.; Racz, A.; Salamon, P. [University of Debrecen, Faculty of Informatics, Chair of Applied Mathematics and Probability, Debrecen, Hungary and Institute of Nuclear Research of the Hungarian Academy of Sciences, Debrecen (Hungary); Institute of Nuclear Research of the Hungarian Academy of Sciences, Debrecen (Hungary); University of Debrecen, Faculty of Informatics, Chair of Applied Mathematics and Probability, Debrecen (Hungary); Institute of Nuclear Research of the Hungarian Academy of Sciences, Debrecen (Hungary)

2012-09-26T23:59:59.000Z

287

DOE/EA-1636: Albany-Burnt Woods and Santiam-Toledo Pole Replacement Project Preliminary Environmental Assessment (March 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Albany-Burnt Woods and Albany-Burnt Woods and Santiam-Toledo Pole Replacement Project Preliminary Environmental Assessment DOE/EA-1636 March 2009 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Albany-Burnt Woods and Santiam-Toledo Pole Replacement Project Preliminary Environmental Assessment DOE/EA-1636 Bonneville Power Administration March 2009 Bonneville Power Administration i Table of Contents Chapter 1 Need for and Purpose of Action ............................................................... 1-1 1.1 Introduction .....................................................................................................

288

Functional design criteria exploratory shaft power line and substation Project B-417  

SciTech Connect

This project will provide a 13.8-KV, 3-phase electrical power line from substation B-251 to the ES site. The power line will be sized to carry the 6000 KVA power required to meet the construction and operations power requirements of the facility. The line will originate at an existing circuit breaker at the 13.8 KV switch gear at substation B-251 and will terminate at fused cutouts at the ES site. Wood poles will be used for the aerial support of the {approximately}4.7 mile transmission line. Joint use of the line by project B-316 is being considered. The substation will provide transformation from 13.8 KV to 2.4 KV, transformer mounting, grounding grid for the entire substation, the substation fence, and connection between the primary side of the transformer and the 13.8 KV electrical line (last pole) provided by Part 1. Switching stations, protective devices, and metering, which are normally part of a substation, will be provided by the ES Project, B-314. 10 refs.

Schroeder, B.K.

1981-12-01T23:59:59.000Z

289

Conceptual Design Report, Exploratory Shaft Power Line and Substation, Project B-417  

SciTech Connect

This project will provide a 13.8-KV, 3-phase electrical power line from substation B-251 to the ES site. The power line will be sized to carry the 6000 KVA power required to meet the construction and operations power requirements of the facility. The line will originate at an existing circuit breaker at the 13.8 KV switch gear at substation B-251 and will terminate at fused cutouts at the ES site. Wood poles will be used for the aerial support of the {approximately}4.7 mi. transmission line. Joint use of the line by project B-316 is being considered. This part will provide transformation from 13.8 KV to 2.4 KV, transformer mounting, grounding grid for the entire substation, the substation fence, and connection between the primary side of the transformer and the 13.8 KV electrical line (last pole) provided by Part I. Switching stations, protective devices, and metering, which are normally part of a substation, will be provided by the ES project, B-314. This report includes drawings, cost estimates and schedules.

Schroeder, B.K. (Kaiser Engineers Hanford Co., Richland, WA (USA))

1982-03-01T23:59:59.000Z

290

BlackLining Demo BlackLining Demo  

E-Print Network (OSTI)

BlackLining Demo BlackLining Demo BlackLining Demo YOUR PAYCHECKPAYROLL TAXES AND EMPLOYMENT LAW BY SPONSORED BY #12;BlackLining Demo e BlackLining Demo e BlackLining Demo e AMERICAN PAYROLL ASSOCIATION i Design by PRIWORKS.com. Images from Thinkstock.com. #12;BlackLining Demo BlackLining Demo Black

Harms, Kyle E.

291

ANALYSIS OF CORONAL GREEN LINE PROFILES: EVIDENCE OF EXCESS BLUESHIFTS  

SciTech Connect

Coronal green line (Fe XIV 5303 A) profiles were obtained from Fabry-Perot interferometric observations of the solar corona during the total solar eclipse of 2001 June 21 from Lusaka, Zambia. The instrumental width is about 0.2 A and the spectral resolution is about 26,000. About 300 line profiles were obtained within a radial range of 1.0-1.5 R{sub sun} and a position angle coverage of about 240{sup 0}. The line profiles were fitted with single Gaussians, and their intensities, Doppler velocities, and line widths were obtained. Also obtained were the centroids of the line profiles, which give a measure of line asymmetry. The histograms of Doppler velocity show excess blueshifts, while the centroids reveal a predominant blue wing in the line profiles. It was found that the centroids and the Doppler velocities are highly correlated. This points to the presence of multiple components in the line profiles, with an excess of blueshifted components. We then obtained the (Blue-Red) wing intensities, which clearly reveal the secondary components, the majority of which are blueshifted. This confirms that the coronal green line profiles often contain multicomponents with excess blueshifts, which also depend on the solar activity. The magnitude of the Doppler velocity of the secondary components is in the range of 20-40 km s{sup -1} and shows an increase toward the poles. Possible explanations of the multicomponents are the type II spicules that were recently found to be important to coronal heating or the nascent solar wind flow, but the cause of the blue asymmetry in the coronal lines above the limb remains unclear.

Raju, K. P. [Indian Institute of Astrophysics, Bangalore (India); Chandrasekhar, T.; Ashok, N. M., E-mail: kpr@iiap.res.in, E-mail: chandra@prl.res.in, E-mail: ashok@prl.res.in [Physical Research Laboratory, Ahmedabad (India)

2011-08-01T23:59:59.000Z

292

Microsoft Word - CX-ForestGrove-McMinnvilleWoodPolesFY12_WEB.docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5, 2012 5, 2012 REPLY TO ATTN OF: KEP-Alvey SUBJECT: Environmental Clearance Memorandum James Semrau Project Manager - TEP-TPP-1 Proposed Action: Forest Grove-McMinnville #1 Wood Pole Replacement Projects PP&A Project No.: 2326 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Proposed by: Bonneville Power Administration (BPA) Location: The project is located in Washington and Yamhill counties, Oregon, in BPA's Salem District. Structure locations are as follows: Structure Legal Description County, State 2\5 1S, 3W, Sec. 6 Washington, OR 3\3 1S, 3W, Sec. 7 Washington, OR 3\6, 4\3 1S. 4W, Sec. 12 Washington, OR 4\8, 4\9, 5\3 1S, 4W, Sec. 14 Washington, OR 6\2, 6\5 1S, 4W, Sec. 23 Washington, OR

293

Microsoft Word - CX-SpokaneDistrictWoodPoleReplacementsFY13_WEB.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1, 2013 1, 2013 REPLY TO ATTN OF: KEPR-Bell-1 SUBJECT: Environmental Clearance Memorandum Amanda Williams Project Manager - TEP-TPP-1 Proposed Action: 2013 Spokane District Wood Pole Replacement Projects PP&A Project No.: 2131 (Albeni Falls-Sand Creek No. 1), 2132 (Bronx-Sand Creek No. 1), 2492 (Albeni Falls-Pine Street No. 1), 2133 (Bell-Boundary No. 3), 2134 (Bell-Addy No. 1), 2135 (Bell-Trentwood No. 1), 2136 (Bell-Trentwood No. 2), 2137 (Libby-Bonners Ferry No. 1), 2493 (Boundary-Nelway #1), 2494 (Colville-Boundary #1), 1547 (Four Lakes Tap), 2138 (Green Bluff Tap), 2495 (Sand Creek-Bonners Ferry No. 1 and No. 2), and 1929 (Spirit Tap) Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance

294

Generation of polarization entangled photons using type-II doubly periodically poled lithium niobate waveguides  

E-Print Network (OSTI)

In this paper, we address the issue of the generation of non-degenerate cross-polarization entangled photon-pairs using type-II periodically poled lithium niobate. We show that, by an appropriate engineering of the quasi-phase-matching grating, it is possible to simultaneously satisfy the conditions for two spontaneous parametric down-conversion processes, namely ordinary pump photon down-conversion to either extraordinary signal and ordinary idler paired photons, or to ordinary signal and extraordinary idler paired photons. In contrast to single type-II phase-matching, these two processes, when enabled together, can lead to the direct production of cross-polarization entangled state for non degenerate signal and idler wavelengths. Such a scheme should be of great interest in applications requiring polarization entangled non degenerate paired photons with, for instance, one of the entangled photons at an appropriate wavelength being used for local operation or for quantum storage in an atomic ensemble, and th...

Thyagarajan, K; Lugani, J; Ghosh, S; Martin, A; Ostrowsky, D B; Alibart, O; Tanzilli, S

2009-01-01T23:59:59.000Z

295

Final environmental assessment for vegetation control at VHF stations, microwave stations, electrical substations, and pole yards  

Science Conference Proceedings (OSTI)

Southwestern Power Adm. operates very high frequency (VHF) and microwave radio stations, electrical substations, and pole yards for electric power transmission throughout AR, MO, and OK. Vegetation growth at the stations must be suppressed for safety of operation and personnel. Southwestern has been using a combination of mechanical/manual and herbicide control for this purpose; Federally- mandated reductions in staff and budgetary resources require Southwestern to evaluate all potentially efficient methods for vegetation control. Three alternatives were examined: no action, mechanical/manual control, and (proposed) a combination of mechanical/manual and herbicide control. Environmental impacts on air and water quality, wetlands, wildlife, endangered species, archaeological and other resources, farmland, human health, transportation, etc. were evaluated.

NONE

1995-10-13T23:59:59.000Z

296

North Australian Cloud Lines  

Science Conference Proceedings (OSTI)

A satellite classification and climatology of propagating mesoscale cloud fines in northern Australia is presented. These cloud fines range from long, narrow lines of shallow convection to extensive deep convective squall lines with mesoscale ...

W. Drosdowsky; G. J. Holland

1987-11-01T23:59:59.000Z

297

The cost of service quality improvements: tracking the flow of funds in social franchise networks in Myanmar  

E-Print Network (OSTI)

administrative overhead to the various lines of service. Thelines and across administrative work vs. quality supervision. Allocating overhead

2013-01-01T23:59:59.000Z

298

Characterization of Planar Transmission Lines  

Science Conference Proceedings (OSTI)

... References on: On-Wafer Measurement and Calibration, Planar Transmission Line Characterization and Multiconductor Transmission Lines. ...

2011-12-15T23:59:59.000Z

299

Application of a Comprehensive Bias-Correction Model to Precipitation Measured at Russian North Pole Drifting Stations  

Science Conference Proceedings (OSTI)

An improved bias correction is applied to daily precipitation measured at Russian North Pole drifting stations during the period from the early 1950s through 1990. The bias-correction method is based on a model accounting for all main systematic ...

Esfir G. Bogdanova; Boris M. Ilyin; Irina V. Dragomilova

2002-12-01T23:59:59.000Z

300

Performance of Weather Forecast Models in the Rescue of Dr. Ronald Shemenski from the South Pole in April 2001  

Science Conference Proceedings (OSTI)

In late April 2001, an unprecedented late-season flight to Amundsen–Scott South Pole Station was made in the evacuation of Dr. Ronald Shemenski, a medical doctor seriously ill with pancreatitis. This case study analyzes the performance of four of ...

Andrew J. Monaghan; David H. Bromwich; He-Lin Wei; Arthur M. Cayette; Jordan G. Powers; Ying-Hwa Kuo; Matthew A. Lazzara

2003-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Cloud Cover over the South Pole from Visual Observations, Satellite Retrievals, and Surface-Based Infrared Radiation Measurements  

Science Conference Proceedings (OSTI)

Estimates of cloud cover over the South Pole are presented from five different data sources: routine visual observations (1957–2004; Cvis), surface-based spectral infrared (IR) data (2001; CPAERI), surface-based broadband IR data (1994–2003; Cpyr)...

Michael S. Town; Von P. Walden; Stephen G. Warren

2007-02-01T23:59:59.000Z

302

Germ-line Allele  

NLE Websites -- All DOE Office Websites (Extended Search)

Germ-line Allele Germ-line Allele Name: Rachel Location: N/A Country: N/A Date: N/A Question: Can you please explain a "germ-line allele" to me! It is very important for a research paper I am writing about breast cancer. Replies: Mutations in genes are only able to be passed to the offspring if they are found in gametes (egg, sperm) mutations that occur in body cells other than gametes are usually not important because the cells can be replaced and they die eventually. The only way a characteristic can be passed to the offspring is through the eggs and sperm, so if there is a mutation in one these cells, the offspring can inherit the mutation. So a germ-line cell is a gamete. And a germ line allele is a version of the trait that is passed to the offspring through the germ line cell (or gamete).

303

Series Transmission Line Transformer  

DOE Patents (OSTI)

A series transmission line transformer is set forth which includes two or more of impedance matched sets of at least two transmissions lines such as shielded cables, connected in parallel at one end ans series at the other in a cascading fashion. The cables are wound about a magnetic core. The series transmission line transformer (STLT) which can provide for higher impedance ratios and bandwidths, which is scalable, and which is of simpler design and construction.

Buckles, Robert A. (Livermore, CA); Booth, Rex (Livermore, CA); Yen, Boris T. (El Cerrito, CA)

2004-06-29T23:59:59.000Z

304

New Construction of Distribution Lines, Service Lines, and Appurtenant...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Resources Outside Residential Subdivisions (New York) New Construction of Distribution Lines, Service Lines, and Appurtenant Facilities in Certain Visually Significant...

305

Microsoft Word - CX-OregonCity-ChemawaWoodPolesFY12_WEB .docx  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alvey Alvey SUBJECT: Environmental Clearance Memorandum James Semrau Project Manager - TEP-TPP-1 Proposed Action: Oregon City-Chemawa #2 Wood Pole Replacement Projects PP&A Project No.: 2327 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.3 Routine maintenance Proposed by: Bonneville Power Administration (BPA) Location: The project is located in Clackamas and Marion counties, Oregon, in BPA's Salem District. Structure locations are as follows: Structure Legal Description County, State 3\14 3S, 1W, Sec. 14 Clackamas, OR 16\12 5S, 2W, Sec. 15 Marion, OR 17\6 5S, 2W, Sec. 22 Marion, OR 20\9 5S, 2W, Sec. 32 Marion, OR 21\3 6S, 2W, Sec. 5 Marion, OR 21\13 - 21\15 6S, 2W, Sec. 6 Marion, OR 21\16 - 22\25 6S, 2W, Sec. 7 Marion, OR

306

Lunar South Pole ice as heat sink for Lunar cryofuel production system  

SciTech Connect

Recent Clementine bistatic radar data suggest that water ice may be present in a {open_quotes}forever shaded{close_quotes} depression or crater at the South Pole of the Moon. The ice is a feedstock for the electrolysis production of cryogenic oxygen and hydrogen rocket fuels for a transportation system on the moon and for leaving and descending on to the moon. The ice also provides a convective heat sink critical to the practical implementation of high throughput electric power generators and refrigerators that liquefy and cool the oxygen and hydrogen into cryogenic rocket fuel. This brief analysis shows that about a hundred tonnes of hardware delivered to the lunar surface can produce tens of thousands of tonnes of rocket fuel per year, on the moon. And it makes the point that if convective cooling is used instead of radiative cooling, then power and processing systems can be used that exist and have been tested already. This shortens the time by an order of magnitude to develop lunar operations. Quick deployment of a chemical cryofuel energy source is a key factor in the economics of lunar development.

Zuppero, A.; Stanley, M.; Modro, S.M. [Idaho National Engineering Lab., Idaho Falls, ID (United States); Whitman, P. [Univ. of Southwestern Louisiana, Lafayette, LA (United States)

1995-03-01T23:59:59.000Z

307

Accelerating Atomic Orbital-based Electronic Structure Calculation via Pole Expansion plus Selected Inversion  

SciTech Connect

We describe how to apply the recently developed pole expansion plus selected inversion (PEpSI) technique to Kohn-Sham density function theory (DFT) electronic structure calculations that are based on atomic orbital discretization. We give analytic expressions for evaluating charge density, total energy, Helmholtz free energy and atomic forces without using the eigenvalues and eigenvectors of the Kohn-Sham Hamiltonian. We also show how to update the chemical potential without using Kohn-Sham eigenvalues. The advantage of using PEpSI is that it has a much lower computational complexity than that associated with the matrix diagonalization procedure. We demonstrate the performance gain by comparing the timing of PEpSI with that of diagonalization on insulating and metallic nanotubes. For these quasi-1D systems, the complexity of PEpSI is linear with respect to the number of atoms. This linear scaling can be observed in our computational experiments when the number of atoms in a nanotube is larger than a few hundreds. Both the wall clock time and the memory requirement of PEpSI is modest. This makes it even possible to perform Kohn-Sham DFT calculations for 10,000-atom nanotubes on a single processor. We also show that the use of PEpSI does not lead to loss of accuracy required in a practical DFT calculation.

Lin, Lin; Chen, Mohan; Yang, Chao; He, Lixin

2012-02-10T23:59:59.000Z

308

Lunar south pole ice as heat sink for lunar cryofuel production system  

DOE Green Energy (OSTI)

Recent Clementine bistatic radar data suggest that water ice may be present in a ``forever shaded`` depression or crater at the South Pole of the Moon. The ice is a feedstock for the electrolysis production of cryogenic oxygen and hydrogen rocket fuel for a transportation system on the moon and for leaving and descending on the moon. The ice also provides a convective heat sink critical to the practical implementation of high throughput electric power generators and refrigerators that liquefy and cool the oxyen and hydrogen into cryogenic rocket fuel. This brief analysis shows that about a hundred tonnes of hardware delivered to the lunar surface can produce tens of thousands of tonnes of rocket fuel per year, on the moon. And it makes the point that if convective cooling is used instead of radiative cooling, then power and processing systems can be used that exist and have been tested already. This shortens the time by an order of magnitude to develop lunar operations. Quick deployment of a chemical cryofuel energy source is a key factor in the economics of lunar development. {copyright}American Institute of Physics 1995

Zuppero, A.; Stanley, M.; Modro, S.M. [PO Box 1625, Idaho National Engineering Laboratory, Idaho Falls, Idaho 83415 (United States); Whitman, P. [University of Southwestern Louisiana, Physics Dept., Center for Accessible Resources, Box 4210, Lafayette, Louisiana 70504 (United States)

1995-01-20T23:59:59.000Z

309

Generation of polarization entangled photons using type-II doubly periodically poled lithium niobate waveguides  

E-Print Network (OSTI)

In this paper, we address the issue of the generation of non-degenerate cross-polarization-entangled photon pairs using type-II periodically poled lithium niobate. We show that, by an appropriate engineering of the quasi-phase-matching grating, it is possible to simultaneously satisfy the conditions for two spontaneous parametric down-conversion processes, namely ordinary pump photon down-conversion to either extraordinary signal and ordinary idler paired photons, or to ordinary signal and extraordinary idler paired photons. In contrast to single type-II phase-matching, these two processes, when enabled together, can lead to the direct production of cross-polarization-entangled state for non degenerate signal and idler wavelengths. Such a scheme should be of great interest in applications requiring polarization-entangled non degenerate paired photons with, for instance, one of the entangled photons at an appropriate wavelength being used for local operation or for quantum storage in an atomic ensemble, and the other one at the typical wavelength of 1550 nm for propagation through an optical fiber.

K. Thyagarajan; K. Sinha; J. Lugani; S. Ghosh; A. Martin; D. B. Ostrowsky; O. Alibart; S. Tanzilli

2009-10-30T23:59:59.000Z

310

Biaxial Flexural Strength of Poled Lead Zirconate Titanate under High Electric Field with Extended Field Range  

Science Conference Proceedings (OSTI)

In the present work, as-received poled lead zirconate titanate, or PZT 5A, was examined using ball-on-ring (BoR) mechanical testing coupled with an electric field. Electric fields in the range of 4Ec (Ec, coercive field) with controlled loading paths were applied, and mechanical tests at a substantial number of characteristic electric field levels were conducted. Commercial electronic liquid FC-40 was used to prevent the setup from dielectric breakdown under a high electric field. Weibull strength distribution was used to interpret the mechanical strength data. The data showed that the strength levels of the PZT-5A tested under OC (open circuit) in air and in FC-40 were almost the same. It was further revealed that , for the studied cases, the effect of loading history on the biaxial flexural strength of the PZT was significant in -Ec, but not in OC or zero field as well as 4Ec . An asymmetry V curve was observed for the characteristic strength-electric field graph, and the bottom of V curve was located near the negative coercive field. Microscopy analysis showed that surface-located volume-distributed flaws were the strength limiter and responsible for the failure of the tested PZT under electromechanical loadings.

Zhang, Kewei [ORNL; Zeng, Fan W [ORNL; Wang, Hong [ORNL; Lin, Hua-Tay [ORNL

2013-01-01T23:59:59.000Z

311

Measurements of Secondary Cosmic Microwave Background Anisotropies with the South Pole Telescope  

E-Print Network (OSTI)

We report cosmic microwave background (CMB) power spectrum measurements from the first 100 sq. deg. field observed by the South Pole Telescope (SPT) at 150 and 220 GHz. On angular scales where the primary CMB anisotropy is dominant, ell ~ 50 at both frequencies. We combine the 150 and 220 GHz data to remove the majority of the point source power, and use the point source subtracted spectrum to detect Sunyaev-Zel'dovich (SZ) power at 2.6 sigma. At ell=3000, the SZ power in the subtracted bandpowers is 4.2 +/- 1.5 uK^2, which is significantly lower than the power predicted by a fiducial model using WMAP5 cosmological parameters. This discrepancy may suggest that contemporary galaxy cluster models overestimate the thermal pressure of intracluster gas. Alternatively, this result can be interpreted as evidence for lower values of sigma8. When combined with an estimate of the kinetic SZ contribution, the measured SZ amplitude shifts sigma8 from the primary CMB anisotropy derived constraint of 0.794 +/- 0.028 down t...

Lueker, M; Schaffer, K K; Zahn, O; Ade, P A R; Aird, K A; Benson, B A; Bleem, L E; Carlstrom, J E; Chang, C L; Cho, H M; Crawford, T M; Crites, A T; de Haan, T; Dobbs, M A; George, E M; Hall, N R; Halverson, N W; Holder, G P; Holzapfel, W L; Hrubes, J D; Joy, M; Keisler, R; Knox, L; Lee, A T; Leitch, E M; McMahon, J J; Mehl, J; Meyer, S S; Mohr, J J; Montroy, T E; Padin, S; Plagge, T; Pryke, C; Ruhl, J E; Shaw, L; Shirokoff, E; Spieler, H G; Staniszewski, Z; Stark, A A; Vanderlinde, K; Vieira, J D; Williamson, R

2009-01-01T23:59:59.000Z

312

EA-1950: Grand Coulee-Creston Transmission Line Rebuild; Grant and Lincoln  

NLE Websites -- All DOE Office Websites (Extended Search)

50: Grand Coulee-Creston Transmission Line Rebuild; Grant and 50: Grand Coulee-Creston Transmission Line Rebuild; Grant and Lincoln Counties, Washington EA-1950: Grand Coulee-Creston Transmission Line Rebuild; Grant and Lincoln Counties, Washington SUMMARY Bonneville Power Administration is preparing this EA to assess the potential environmental impacts of the proposed rebuild of approximately 28 miles of transmission line between the cities of Coulee Dam in Grant County and Creston in Lincoln County, Washington. The proposed project would include replacing all wood pole structures and conductor, improving existing access roads, and developing temporary access roads. Additional information is available at the project website: http://www.bpa.gov/goto/CouleeCrestonRebuild. PUBLIC COMMENT OPPORTUNITIES Draft EA: Comment Period Ends 2/3/14.

313

EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO  

Energy.gov (U.S. Department of Energy (DOE))

DOE’s Western Area Power Administration (Western) owns and operates two 16-mile, 115-kilovolt transmission lines on separate rights-of-way between Flatiron Reservoir (near Loveland, Colorado) and the town of Estes Park, Colorado. Western is preparing this EIS to evaluate the environmental impacts of a proposal to upgrade and co-locate these transmission lines, by removing one and abandoning its right-of-way, and rebuilding the other along the existing right-of-way as a double-circuit line (i.e., six conductors per pole). The USDA Forest Service, Arapaho and Roosevelt National Forest, is a cooperating agency in preparing the EIS to support its decision on whether to grant a Special Use Permit for parts of the transmission line located on National Forest lands.

314

Two-point gauge invariant quark Green's functions with polygonal phase factor lines  

E-Print Network (OSTI)

Polygonal lines are used for the paths of the gluon field phase factors entering in the definition of gauge invariant quark Green's functions. This allows classification of the Green's functions according to the number of segments the polygonal lines contain. Functional relations are established between Green's functions with polygonal lines with different numbers of segments. An integrodifferential equation is obtained for the quark two-point Green's function with a path along a single straight line segment where the kernels are represented by a series of Wilson loop averages along polygonal contours. The equation is exactly and analytically solved in the case of two-dimensional QCD in the large-$N_c$ limit. The solution displays generation of an infinite number of dynamical quark masses accompanied with branch point singularities that are stronger than simple poles. An approximation scheme, based on the counting of functional derivatives of Wilson loops, is proposed for the resolution of the equation in four dimensions.

H. Sazdjian

2013-10-24T23:59:59.000Z

315

Weld-Windsor 115-kV Transmission Line Project, Weld County, Colorado  

Science Conference Proceedings (OSTI)

The Western Area Power Administration is proposing to rebuild a 3.0 mile segment of the existing Flatiron-Weld 115-kV transmission line in Weld County. The line would be reconductored with new conductor on new wood pole double circuit structures. The new structures would support a double circuit transmission line configuration. The first circuit would be owned by Western and the second by Public Service Company of Colorado (PSCO). Alternatives considered included no action, constructing PSCO`s circuit on new right-of-way, and reconductoring Western`s existing line on the same structures. The proposed action was selected because it provided an opportunity to share structures with PSCO and, overall, would minimize costs and environmental impacts. The environmental assessment identifies minor effects on existing natural or human resources and minor benefits for agricultural operations.

NONE

1996-05-01T23:59:59.000Z

316

Wireless Sensor Network for Electric Transmission Line Monitoring  

SciTech Connect

Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and cost effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications. On such a platform, it has been demonstrated in this project that wireless monitoring units can effectively deliver real-time transmission line power flow information for less than $500 per monitor. The data delivered by such a monitor has during the course of the project been integrated with a national grid situational awareness visualization platform developed by Oak Ridge National Laboratory. Novel vibration energy scavenging methods based on piezoelectric cantilevers were also developed as a proposed method to power such monitors, with a goal of further cost reduction and large-scale deployment. Scavenging methods developed during the project resulted in 50% greater power output than conventional cantilever-based vibrational energy scavenging devices typically used to power smart sensor nodes. Lastly, enhanced and new methods for electromagnetic field sensing using multi-axis magnetometers and infrared reflectometry were investigated for potential monitoring applications in situations with a high density of power lines or high levels of background 60 Hz noise in order to isolate power lines of interest from other power lines in close proximity. The goal of this project was to investigate and demonstrate the feasibility of using small form factor, highly optimized, low cost, low power, non-contact, wireless electric transmission line monitors for delivery of real-time, independent power line monitoring for the US power grid. The project was divided into three main types of activity as follows; (1) Research into expanding the range of applications for non-contact power line monitoring to enable large scale low cost sensor network deployments (Tasks 1, 2); (2) Optimization of individual sensor hardware components to reduce size, cost and power consumption and testing in a pilot field study (Tasks 3,5); and (3) Demonstration of the feasibility of using the data from the network of power line monitors via a range of custom developed alerting and data visualization applications to deliver real-time information to federal agencies and others tasked with grid reliability (Tasks 6,8)

Alphenaar, Bruce

2009-06-30T23:59:59.000Z

317

Jordan blocks and Gamow-Jordan eigenfunctions associated to a double pole of the S-matrix  

E-Print Network (OSTI)

An accidental degeneracy of resonances gives rise to a double pole in the scattering matrix, a double zero in the Jost function and a Jordan chain of length two of generalized Gamow-Jordan eigenfunctions of the radial Schroedinger equation. The generalized Gamow-Jordan eigenfunctions are basis elements of an expansion in bound and resonant energy eigenfunctions plus a continuum of scattering wave functions of complex wave number. In this biorthonormal basis, any operator which is a regular function of the Hamiltonian is represented by a complex matrix which is diagonal except for a Jordan block of rank two. The occurrence of a double pole in the Green's function, as well as the non-exponential time evolution of the Gamow-Jordan generalized eigenfunctions are associated to the Jordan block in the complex energy representation.

E. Hernandez; A. Jauregui; A. Mondragon

2002-04-15T23:59:59.000Z

318

 

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pole 178 and the H2A/H2B 13.8-kV overhead line disconnect switch were installed in the early 1950s, and are located southwest of Building 292-H. Pole 178 and the H2A/H2B 13.8-kV overhead line disconnect switch were installed in the early 1950s, and are located southwest of Building 292-H. Replacement of both pieces is proposed because the switch malfunctions each time it operates and the pole is bent which presents a safety hazard. Polychlorinated biphenyls (PCB's) are not an issue because there are no liquids/oils associated with the switch. A Radiological Buffer Area (RBA) will be established prior to start of proposed pole removal activities. Radiological Control Operations (RCO) will survey the pole as it is being removed from hole. After survey, RCO will remove the RBA and the new pole will be placed in the existing hole. The new switch will then be installed on the new pole.

319

 

NLE Websites -- All DOE Office Websites (Extended Search)

Pole 178 and the H2A/H2B 13.8-kV overhead line disconnect switch were installed in the early 1950s, and are located southwest of Building 292-H. Pole 178 and the H2A/H2B 13.8-kV overhead line disconnect switch were installed in the early 1950s, and are located southwest of Building 292-H. Replacement of both pieces is proposed because the switch malfunctions each time it operates and the pole is bent which presents a safety hazard. Polychlorinated biphenyls (PCB's) are not an issue because there are no liquids/oils associated with the switch. A Radiological Buffer Area (RBA) will be established prior to start of proposed pole removal activities. Radiological Control Operations (RCO) will survey the pole as it is being removed from hole. After survey, RCO will remove the RBA and the new pole will be placed in the existing hole. The new switch will then be installed on the new pole.

320

Proposal for the award of a contract for the supply of pole-face windings for the Ps main magnets  

E-Print Network (OSTI)

This document concerns the award of a contract for the supply of 244 pole-face windings for the PS main magnets. Following a market survey carried out among 58 firms in twelve Member States, a call for tenders (IT-3277/AT) was sent on 25 March 2004 to eight firms in seven Member States. By the closing date, CERN had received three tenders from three firms in three Member States. The Finance Committee is invited to agree to the negotiation of a contract with SIGMAPHI (FR), the lowest bidder, for the supply of 244 pole-face windings for a total amount of 1 122 268 euros (1 753 544 Swiss francs), not subject to revision, with an option for up to 240 additional pole-face windings for an amount not exceeding 1 101 299 euros (1 720 780 Swiss francs), not subject to revision, bringing the total amount to 2 223 567 euros (3 474 324 Swiss francs), not subject to revision. The firm has indicated the following distribution by country of the contract value covered by this adjudication proposal: FR - 98%; IT - 2%.

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Investigation of magnetic-pole-enhanced inductively coupled nitrogen-argon plasmas  

SciTech Connect

This article presented the features of the mixed mode and H mode in magnetic pole enhanced, inductively coupled Ar-N{sub 2} plasmas using RF-compensated Langmuir probe measurements. To fully characterize plasma parameters and electron energy probability functions (EEPFs), the gas pressure and argon content were varied. It was observed that with increasing the nitrogen content and gas pressure, the critical RF power to sustain H mode increases; this increase was more prominent for pure nitrogen discharge at higher pressure. The electron number density (n{sub e}) shows increasing trend with increasing RF power, while at higher gas pressures, the electron number density decreases at fixed RF power. Mostly, the EEPFs show a Maxwellian distribution even at low RF power (for higher argon content in the discharge) and at moderate RF power (for higher or pure nitrogen content in the discharge) for pressures of 15-60 mTorr. With increasing the nitrogen content in the mixture, the low energy part of the EEPF is more Druyvesteyn with a distorted high energy tail at low RF power. At fixed RF power, the slope of EEPF changes sharply with increasing pressure. It was observed that in hybrid mode, the EEPF at higher gas pressure (75 mTorr) in a pure nitrogen discharge shows a flat hole near the average electron energy of 3 eV and changes to Maxwellian distribution in H mode. The skin depth versus RF power shows that the skin depth is smaller than the critical dimension of the chamber, regardless of the gas type and the gas pressure.

Jan, F.; Zakaullah, M. [Department of Physics, Quaid-i-Azam University Islamabad, Islamabad 45320 (Pakistan); Khan, A. W.; Saeed, A. [National Centre for Physics, Quaid-i-Azam University Campus Islamabad, Islamabad 45320 (Pakistan)

2012-09-15T23:59:59.000Z

322

Power line detection system  

DOE Patents (OSTI)

A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard. 4 figs.

Latorre, V.R.; Watwood, D.B.

1994-09-27T23:59:59.000Z

323

Electric Transmission Lines (Iowa)  

Energy.gov (U.S. Department of Energy (DOE))

Electric transmission lines capable of operating at 69 kV or greater cannot be constructed along, across, or over any public highways or grounds outside of cities without a franchise from the...

324

Power line detection system  

DOE Patents (OSTI)

A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard.

Latorre, Victor R. (Tracy, CA); Watwood, Donald B. (Tracy, CA)

1994-01-01T23:59:59.000Z

325

Transmission Line Grounding  

Science Conference Proceedings (OSTI)

In 2008, the Electric Power Research Institute (EPRI) published a comprehensive grounding report. Published in two parts, the report covered the theoretical and practical aspects of transmission line grounding practices. To further improve the tools available for grounding analysis, an investigation into practical ways to calculate the fault current distribution and ground potential rise of the transmission line grounding system was conducted. Furthermore, a survey of utilities has documented industry pr...

2011-12-23T23:59:59.000Z

326

Transmission line capital costs  

Science Conference Proceedings (OSTI)

The displacement or deferral of conventional AC transmission line installation is a key benefit associated with several technologies being developed with the support of the U.S. Department of Energy`s Office of Energy Management (OEM). Previous benefits assessments conducted within OEM have been based on significantly different assumptions for the average cost per mile of AC transmission line. In response to this uncertainty, an investigation of transmission line capital cost data was initiated. The objective of this study was to develop a database for preparing preliminary estimates of transmission line costs. An extensive search of potential data sources identified databases maintained by the Bonneville Power Administration (BPA) and the Western Area Power Administration (WAPA) as superior sources of transmission line cost data. The BPA and WAPA data were adjusted to a common basis and combined together. The composite database covers voltage levels from 13.8 to 765 W, with cost estimates for a given voltage level varying depending on conductor size, tower material type, tower frame type, and number of circuits. Reported transmission line costs vary significantly, even for a given voltage level. This can usually be explained by variation in the design factors noted above and variation in environmental and land (right-of-way) costs, which are extremely site-specific. Cost estimates prepared from the composite database were compared to cost data collected by the Federal Energy Regulatory Commission (FERC) for investor-owned utilities from across the United States. The comparison was hampered because the only design specifications included with the FERC data were voltage level and line length. Working within this limitation, the FERC data were not found to differ significantly from the composite database. Therefore, the composite database was judged to be a reasonable proxy for estimating national average costs.

Hughes, K.R.; Brown, D.R.

1995-05-01T23:59:59.000Z

327

A MEASUREMENT OF SECONDARY COSMIC MICROWAVE BACKGROUND ANISOTROPIES WITH TWO YEARS OF SOUTH POLE TELESCOPE OBSERVATIONS  

SciTech Connect

We present the first three-frequency South Pole Telescope (SPT) cosmic microwave background (CMB) power spectra. The band powers presented here cover angular scales 2000 < l < 9400 in frequency bands centered at 95, 150, and 220 GHz. At these frequencies and angular scales, a combination of the primary CMB anisotropy, thermal and kinetic Sunyaev-Zel'dovich (SZ) effects, radio galaxies, and cosmic infrared background (CIB) contributes to the signal. We combine Planck/HFI and SPT data at 220 GHz to constrain the amplitude and shape of the CIB power spectrum and find strong evidence for nonlinear clustering. We explore the SZ results using a variety of cosmological models for the CMB and CIB anisotropies and find them to be robust with one exception: allowing for spatial correlations between the thermal SZ effect and CIB significantly degrades the SZ constraints. Neglecting this potential correlation, we find the thermal SZ power at 150 GHz and l = 3000 to be 3.65 {+-} 0.69 {mu}K{sup 2}, and set an upper limit on the kinetic SZ power to be less than 2.8 {mu}K{sup 2} at 95% confidence. When a correlation between the thermal SZ and CIB is allowed, we constrain a linear combination of thermal and kinetic SZ power: D{sup tSZ}{sub 3000} + 0.5D{sub 3000}{sup kSZ} = 4.60 {+-} 0.63 {mu}K{sup 2}, consistent with earlier measurements. We use the measured thermal SZ power and an analytic, thermal SZ model calibrated with simulations to determine {sigma}{sub 8} = 0.807 {+-} 0.016. Modeling uncertainties involving the astrophysics of the intracluster medium rather than the statistical uncertainty in the measured band powers are the dominant source of uncertainty on {sigma}{sub 8}. We also place an upper limit on the kinetic SZ power produced by patchy reionization; a companion paper uses these limits to constrain the reionization history of the universe.

Reichardt, C. L.; George, E. M.; Holzapfel, W. L. [Department of Physics, University of California, Berkeley, CA 94720 (United States); Shaw, L. [Department of Physics, Yale University, P.O. Box 208210, New Haven, CT 06520-8120 (United States); Zahn, O. [Berkeley Center for Cosmological Physics, Department of Physics, University of California, and Lawrence Berkeley National Labs, Berkeley, CA 94720 (United States); Aird, K. A. [University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Benson, B. A.; Bleem, L. E.; Carlstrom, J. E.; Chang, C. L.; Crawford, T. M.; Crites, A. T.; Hoover, S. [Kavli Institute for Cosmological Physics, University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Cho, H. M. [NIST Quantum Devices Group, 325 Broadway Mailcode 817.03, Boulder, CO 80305 (United States); De Haan, T.; Dobbs, M. A.; Dudley, J.; Holder, G. P. [Department of Physics, McGill University, 3600 Rue University, Montreal, Quebec H3A 2T8 (Canada); Halverson, N. W. [Department of Astrophysical and Planetary Sciences and Department of Physics, University of Colorado, Boulder, CO 80309 (United States); Hou, Z., E-mail: cr@bolo.berkeley.edu [Department of Physics, University of California, One Shields Avenue, Davis, CA 95616 (United States); and others

2012-08-10T23:59:59.000Z

328

New Construction of Distribution Lines, Service Lines, and Appurtenant  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New Construction of Distribution Lines, Service Lines, and New Construction of Distribution Lines, Service Lines, and Appurtenant Facilities in Certain Visually Significant Resources Outside Residential Subdivisions (New York) New Construction of Distribution Lines, Service Lines, and Appurtenant Facilities in Certain Visually Significant Resources Outside Residential Subdivisions (New York) < Back Eligibility Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State New York Program Type Environmental Regulations Provider New York State Public Service Commission Any proposed construction of distribution lines, service lines, and appurtenant facilities to electric utilities located near scenic areas of

329

2005 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE  

U.S. Energy Information Administration (EIA)

2010 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE. Kerosene. ... • Geothermal energy drilling company • Logging company •Privately owned port or loading dock

330

Nanoscale SRAM Variability and Optimization  

E-Print Network (OSTI)

area overhead required for short read bit-lines, dual word-word-line samplers contribute to a 16% array area overhead.bit-lines. Although this requires more area overhead, this

Toh, Seng Oon

2011-01-01T23:59:59.000Z

331

Suburban citizenship  

E-Print Network (OSTI)

Powerlink involved overhead lines to be strung from one endthan the planned overhead lines would have been. They arguesaw the overhead high tension power lines as a threat to

Vandehey, Scott Lawrence

2009-01-01T23:59:59.000Z

332

SPEAR3 Beam Line Availability  

NLE Websites -- All DOE Office Websites (Extended Search)

Beam Line Support | Floor Support | Administrative Support SPEAR3 Beam Line Availability Beam Line BL Type Technique(s) Status 1-4 X-ray Small and Wide Angle X-ray Scattering Open...

333

Utility Line Inspections and Audits  

Science Conference Proceedings (OSTI)

Utility Line Inspections and Audits provides utility engineers with a concise reference for the pros, cons, and how to related to performing various line inspections and audits.

2007-03-21T23:59:59.000Z

334

Omega Transmission Lines  

E-Print Network (OSTI)

In this paper, we show how bi-anisotropic media with omega-type response can be realized using periodically loaded transmission lines. General conditions for the needed unit cell circuit block are derived. Also, an implementation is shown and analyzed.

Vehmas, Joni

2013-01-01T23:59:59.000Z

335

On line course organization  

Science Conference Proceedings (OSTI)

In order to help users access on-line materials with more specific questions, we build a learning portal named Fusion. First we develop Fusion-Crawler, a link classification focused crawler, to download potential course pages. We then use a binary classifier ... Keywords: focused crawling, learning object management, metadata extraction, ontology

Ming Zhang; Weichun Wang; Yi Zhou; Yu Yang; Yuhong Xiong; Xiaoming Li

2007-08-01T23:59:59.000Z

336

NEPA COMPLIANCE SURVEY Project Information Project Title:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New power Line for new generator at ten sleep New power Line for new generator at ten sleep Dat e: 12114/10 DOE Code: Contractor Code: Project Lead: Mike Preston Project Overview 1. Brief project description (include Extend 3 phase power line from (existing) pole 99 to the Ten Sleep location for a new generator. The anything that could impact the transformer bank at the WDF will be dismantled, the line extended overhead, across 5 new power poles, to environment) the Ten Sleep Battery and the bank will be reassembled there. The new guy anchor at pole 99 will be located outside Palustrine wetlands. The line will be 34.5/19.920 KV, approximately 1,200 feet in length. 2. Legal location Ground disturbance will be minimal and have very little potential to affect the environment. 3. Duration of the project

337

Stereoscopic 3D line drawing  

Science Conference Proceedings (OSTI)

This paper discusses stereoscopic 3D imaging based on line drawing of 3D shapes. We describe the major issues and challenges in generating stereoscopic 3D effects using lines only, with a couple of relatively simple approaches called each-eye-based and ... Keywords: binocular rivalry, line drawing, line stylization, non-photorealism, stereo coherence, stereoscopy

Yongjin Kim; Yunjin Lee; Henry Kang; Seungyong Lee

2013-07-01T23:59:59.000Z

338

Printed circuit dispersive transmission line  

DOE Patents (OSTI)

A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other. 5 figures.

Ikezi, H.; Lin-Liu, Y.R.; DeGrassie, J.S.

1991-08-27T23:59:59.000Z

339

Printed circuit dispersive transmission line  

DOE Patents (OSTI)

A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other.

Ikezi, Hiroyuki (Rancho Santa Fe, CA); Lin-Liu, Yuh-Ren (San Diego, CA); DeGrassie, John S. (Encinitas, CA)

1991-01-01T23:59:59.000Z

340

Printed circuit dispersive transmission line  

DOE Patents (OSTI)

A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission lines between two adjacent periodic intersections to be longer than the other. 5 figs.

Ikezi, Hiroyuki; Lin-Liu, Yuh-Ren; deGrassie, J.S.

1990-03-02T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Ultrabroadband optical parametric chirped-pulse amplifier using a fan-out periodically poled crystal with spectral spatial dispersion  

Science Conference Proceedings (OSTI)

Based on the full two-dimensional characteristics of the quasi-phase-matched fan-out periodically poled crystal, a scalable and engineerable scheme for ultrabroadband optical parametric chirped-pulse amplification is proposed, which can significantly broaden the gain bandwidth by the spatial separation of different frequency components of the signal pulse and manipulation of the distribution of the pump beam along the fan-out direction of the crystal. The theoretical analysis shows that the signal pulse can be amplified with minimal spectrum narrowing, and the initial spectrum can be broadened considerably if needed. Based on this scheme, using a fan-out periodically poled 5% mol MgO-doped congruent lithium niobate with a configuration of 5x0.5x5 mm{sup 3} and two pump beams, the 3.3-{mu}m middle-infrared ultrabroadband optical parametric chirped-pulse amplifier is designed. The numerical computation results confirm that the -3 dB gain bandwidth of this amplifier exceeds 320 nm and can be further broadened.

Chen Liezun; Wang Youwen [Key Laboratory for Micro/Nano Optoelectronic Devices of Ministry of Education, School of Information Science and Engineering, Hunan University, Changsha 410082 (China); Department of Physics and Electronic Information Science, Hengyang Normal University, Hengyang 421008 (China); Wen Shuangchun; Fan Dianyuan [Key Laboratory for Micro/Nano Optoelectronic Devices of Ministry of Education, School of Information Science and Engineering, Hunan University, Changsha 410082 (China); You Kaiming [Department of Physics and Electronic Information Science, Hengyang Normal University, Hengyang 421008 (China); Qian Liejia [Department of Optical Science and Engineering, Fudan University, Shanghai 200433 (China)

2010-10-15T23:59:59.000Z

342

Drill string transmission line  

DOE Patents (OSTI)

A transmission line assembly for transmitting information along a downhole tool comprising a pin end, a box end, and a central bore traveling between the pin end and the box end, is disclosed in one embodiment of the invention as including a protective conduit. A transmission line is routed through the protective conduit. The protective conduit is routed through the central bore and the ends of the protective conduit are routed through channels formed in the pin end and box end of the downhole tool. The protective conduit is elastically forced into a spiral or other non-linear path along the interior surface of the central bore by compressing the protective conduit to a length within the downhole tool shorter than the protective conduit.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David S. (Lehi, UT); Bradford, Kline (Orem, UT); Fox, Joe (Spanish Fork, UT)

2006-03-28T23:59:59.000Z

343

Nonlinear magnetoinductive transmission lines  

E-Print Network (OSTI)

Power transmission in one-dimensional nonlinear magnetic metamaterials driven at one end is investigated numerically and analytically in a wide frequency range. The nonlinear magnetic metamaterials are composed of varactor-loaded split-ring resonators which are coupled magnetically through their mutual inductances, forming thus a magnetoiductive transmission line. In the linear limit, significant power transmission along the array only appears for frequencies inside the linear magnetoinductive wave band. We present analytical, closed form solutions for the magnetoinductive waves transmitting the power in this regime, and their discrete frequency dispersion. When nonlinearity is important, more frequency bands with significant power transmission along the array may appear. In the equivalent circuit picture, the nonlinear magnetoiductive transmission line driven at one end by a relatively weak electromotive force, can be modeled by coupled resistive-inductive-capacitive (RLC) circuits with voltage-dependent cap...

Lazarides, Nikos; Tsironis, G P

2011-01-01T23:59:59.000Z

344

PROCEEDINGS OF THE THIRD BERKELEY WORKSHOP ON DISTRIBUTED DATA MANAGEMENT AND COMPUTER NETWORKS  

E-Print Network (OSTI)

throughput and line utilization include overhead (i,e,overhead is application dependent, and a simulation model (perhaps along the lines

Authors, Various

2011-01-01T23:59:59.000Z

345

Optimization and Performance Modeling of Stencil Computations on Modern Microprocessors  

E-Print Network (OSTI)

cache line from main memory requires a higher overhead (C fcache line from main memory, C f irst , by the overhead of

Datta, Kaushik

2009-01-01T23:59:59.000Z

346

Power Efficient Scheduling for Network Applications on Multicore Architecture  

E-Print Network (OSTI)

the overhead for Stop&Go and task migration (line 8-15 inthe least overhead and take appropriate action. (line 8-15)

Kuang, Jilong

2011-01-01T23:59:59.000Z

347

PROCEEDINGS OF FOURTH BERKELEY CONFERENCE ON DISTRIBUTED DATA MANAGEMENT AND COMPUTER NETWORKS.  

E-Print Network (OSTI)

H. Opderbeck "A Study of Line Overhead in the ARPANET"overhead software, an important consideration in memory limited microprocessors. The logic design of the line

Hall, Dennis

2011-01-01T23:59:59.000Z

348

PROCEEDINGS OF THE FIFTH BERKELEY WORKSHOP ON DISTRIBUTED DATA MANAGEMENT AND COMPUTER NETWORKS  

E-Print Network (OSTI)

Opderbeck, "A study of line overhead in the ARPANET," Comm.features [2]: the line overhead is less than one percent and

Johnson, R.R.

2011-01-01T23:59:59.000Z

349

A Debugging System for Sensor Networks  

E-Print Network (OSTI)

more to the left a line is the less overhead, and the morevertical a line is the less overhead. As expected, the 9

Nithya Ramanathan; Kevin Chang; Rahul Kapur; Lewis Girod; Eddie Kohler; Deborah Estrin

2005-01-01T23:59:59.000Z

350

New Construction of Distribution Lines, Service Lines, and Appurtenant  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Construction of Distribution Lines, Service Lines, and Construction of Distribution Lines, Service Lines, and Appurtenant Facilities in Residential Subdivisions (New York) New Construction of Distribution Lines, Service Lines, and Appurtenant Facilities in Residential Subdivisions (New York) < Back Eligibility Commercial Installer/Contractor Institutional Investor-Owned Utility Low-Income Residential Multi-Family Residential Municipal/Public Utility Residential Rural Electric Cooperative Schools Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Home Weatherization Water Buying & Making Electricity Solar Wind Program Info State New York Program Type Siting and Permitting Provider New York State Public Service Commission Any proposed construction of electricity-related facilities in residential

351

The Imaging and Medical Beam Line at the Australian Synchrotron  

Science Conference Proceedings (OSTI)

As a result of the enthusiastic support from the Australian biomedical, medical and clinical communities, the Australian Synchrotron is constructing a world-class facility for medical research, the 'Imaging and Medical Beamline'. The IMBL began phased commissioning in late 2008 and is scheduled to commence the first clinical research programs with patients in 2011. It will provide unrivalled x-ray facilities for imaging and radiotherapy for a wide range of research applications in diseases, treatments and understanding of physiological processes. The main clinical research drivers are currently high resolution and sensitivity cardiac and breast imaging, cell tracking applied to regenerative and stem cell medicine and cancer therapies. The beam line has a maximum source to sample distance of 136 m and will deliver a 60 cm by 4 cm x-ray beam1 - monochromatic and white - to a three storey satellite building fully equipped for pre-clinical and clinical research. Currently operating with a 1.4 Tesla multi-pole wiggler, it will upgrade to a 4.2 Tesla device which requires the ability to handle up to 21 kW of x-ray power at any point along the beam line. The applications envisaged for this facility include imaging thick objects encompassing materials, humans and animals. Imaging can be performed in the range 15-150 keV. Radiotherapy research typically requires energies between 30 and 120 keV, for both monochromatic and broad beam.

Hausermann, Daniel; Hall, Chris; Maksimenko, Anton; Campbell, Colin [Australian Synchrotron Company, 800 Blackburn Road, Clayton, Victoria 3168 (Australia)

2010-07-23T23:59:59.000Z

352

Commercial Lining Products  

Science Conference Proceedings (OSTI)

Table 1   Comparative ranking of rubber lining materials...Heat Oxidation Ultraviolet Abrasion Weathering Oil Motor fuels Acid Alkali Flame Natural rubber NR 5 4 4 4 4 6 6 3 3 6 Styrene-butadiene SBR 4 3 3 2 4 5 6 3 3 6 Nitrile NBR 3 3 3 2 3 1 6 4 4 6 Chloroprene CR 2 2 2 3 2 2 3 1 2 2 Chlorosulfonylpolyethylene CSM 2 2 2 3 2 2 2 2 2 3 Isobutylene-isoprene...

353

Accelerated line-search and trust-region methods  

E-Print Network (OSTI)

Apr 3, 2008 ... funded by the Interuniversity Attraction Poles Programme, initiated by the Belgian State, Science Policy Office. The scientific responsibility rests ...

354

Utility Lines and Facilities (Montana)  

Energy.gov (U.S. Department of Energy (DOE))

These regulations apply to the construction of utility and power lines and facilities. They address the use of public right-of-ways for such construction, underground power lines, and construction...

355

A MEASUREMENT OF THE CORRELATION OF GALAXY SURVEYS WITH CMB LENSING CONVERGENCE MAPS FROM THE SOUTH POLE TELESCOPE  

Science Conference Proceedings (OSTI)

We compare cosmic microwave background lensing convergence maps derived from South Pole Telescope (SPT) data with galaxy survey data from the Blanco Cosmology Survey, WISE, and a new large Spitzer/IRAC field designed to overlap with the SPT survey. Using optical and infrared catalogs covering between 17 and 68 deg{sup 2} of sky, we detect a correlation between the SPT convergence maps and each of the galaxy density maps at >4{sigma}, with zero correlation robustly ruled out in all cases. The amplitude and shape of the cross-power spectra are in good agreement with theoretical expectations and the measured galaxy bias is consistent with previous work. The detections reported here utilize a small fraction of the full 2500 deg{sup 2} SPT survey data and serve as both a proof of principle of the technique and an illustration of the potential of this emerging cosmological probe.

Bleem, L. E.; Becker, M. R.; Benson, B. A.; Carlstrom, J. E.; Chang, C. L.; Crawford, T. M.; Crites, A. T. [Kavli Institute for Cosmological Physics, University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Van Engelen, A.; Holder, G. P.; De Haan, T.; Dobbs, M. A. [Department of Physics, McGill University, 3600 Rue University, Montreal, Quebec H3A 2T8 (Canada); Aird, K. A. [University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Armstrong, R. [National Center for Supercomputing Applications, University of Illinois, 1205 West Clark Street, Urbana, IL 61801 (United States); Ashby, M. L. N. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Biesiadzinski, T. [Department of Physics, University of Michigan, 450 Church Street, Ann Arbor, MI 48109 (United States); Brodwin, M. [Department of Physics and Astronomy, University of Missouri, 5110 Rockhill Road, Kansas City, MO 64110 (United States); Busha, M. T. [Institute for Theoretical Physics, University of Zuerich, Zuerich (Switzerland); Cho, H. M. [NIST Quantum Devices Group, 325 Broadway, Mailcode 817.03, Boulder, CO 80305 (United States); Desai, S. [Department of Physics, Ludwig-Maximilians-Universitaet, Scheinerstr. 1, 81679 Muenchen (Germany); Dore, O. [Division of Physics, Mathematics, and Astronomy, California Institute of Technology, MS 249-17, 1216 East California Blvd., Pasadena, CA 91125 (United States); and others

2012-07-01T23:59:59.000Z

356

Strong Lines of Mercury ( Hg )  

Science Conference Proceedings (OSTI)

... Mercury (Hg) Homepage - Introduction Finding list Select element by name. Select element by atomic number. ... Strong Lines of Mercury ( Hg ). ...

357

Strong Lines of Plutonium ( Pu )  

Science Conference Proceedings (OSTI)

... Plutonium (Pu) Homepage - Introduction Finding list Select element by name. Select element by atomic number. ... Strong Lines of Plutonium ( Pu ). ...

358

Strong Lines of Hydrogen ( H )  

Science Conference Proceedings (OSTI)

... Hydrogen (H) Homepage - Introduction Finding list Select element by name. Select element by atomic number. ... Strong Lines of Hydrogen ( H ). ...

359

Strong Lines of Tungsten ( W )  

Science Conference Proceedings (OSTI)

... Tungsten (W) Homepage - Introduction Finding list Select element by name. Select element by atomic number. ... Strong Lines of Tungsten ( W ). ...

360

Modeling Interregional Transmission Congestion in the National Energy  

E-Print Network (OSTI)

Standard for digital optical transmission (bit pipe) q Developed originally by Bellcore. Standardized Overhead 90 Columns Synchronous Payload Envelope 9 Rows Line Overhead 6 Rows #12;Raj JainThe Ohio State Overhead 3 Rows Path Overhead 270 Columns Synchronous Payload Envelope 9 Rows Line Overhead 6 Rows #12;Raj

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Deployment of a Tethered-Balloon System for Microphysics and Radiative Measurements in Mixed-Phase Clouds at Ny-Ålesund and South Pole  

Science Conference Proceedings (OSTI)

A tethered-balloon system capable of making microphysical and radiative measurements in clouds is described and examples of measurements in boundary layer stratus clouds in the Arctic and at the South Pole are presented. A 43-m3 helium-filled ...

R. Paul Lawson; Knut Stamnes; Jakob Stamnes; Pat Zmarzly; Jeff Koskuliks; Chris Roden; Qixu Mo; Michael Carrithers; Geoffrey L. Bland

2011-05-01T23:59:59.000Z

362

CX-005674: Categorical Exclusion Determination | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

674: Categorical Exclusion Determination 674: Categorical Exclusion Determination CX-005674: Categorical Exclusion Determination Portland General Electric Overhead Line Crossing of Keeler-Oregon City CX(s) Applied: B4.9 Date: 04/15/2011 Location(s): Willamette Meridian, Oregon Office(s): Bonneville Power Administration Portland General Electric (PGE) is planning to construct an overhead transmission line to tap into their existing Saint Mary?s Substation from their newly built Cornell Substation. PGE?s new 115-kilovolt transmission line would cross over Bonneville Power Administration's (BPA) Keeler-Oregon City # 2 transmission line at the junction of the line and Oregon State Highway 26. Their plan includes installation of a two-pole H-Frame structure to control conductor height at the crossing. BPA is proposing to

363

Plasma Modes Along the Open Field Lines of a Neutron Star  

E-Print Network (OSTI)

We consider electrostatic plasma modes along the open field lines of a rotating neutron star. Goldreich-Julian charge density in general relativity is analyzed for the neutron star with zero inclination. It is found that the charge density is maximum at the polar cap and it remains almost same in certain extended region of the pole. For a steady state Goldreich-Julian charge density we found the usual plasma oscillation along the field lines; plasma frequency resembles to the gravitational redshift close to the Schwarzschild radius. We study the nonlinear plasma mode along the field lines. From the system of equations under general relativity, a second order differential equation is derived. The equation contains a term which describes the growing plasma modes near Schwarzschild radius in a black hole environment. The term vanishes with the distance far away from the gravitating object. For initially zero potential and field on the surface of a neutron star, Goldreich-Julian charge density is found to create the plasma mode, which is enhanced and propagates almost without damping along the open field lines. We briefly outline our plan to extend the work for studying soliton propagation along the open field lines of strongly gravitating objects.

U. A. Mofiz; B. J. Ahmedov

2007-05-30T23:59:59.000Z

364

EC Transmission Line Materials  

SciTech Connect

The purpose of this document is to identify materials acceptable for use in the US ITER Project Office (USIPO)-supplied components for the ITER Electron cyclotron Heating and Current Drive (ECH&CD) transmission lines (TL), PBS-52. The source of material property information for design analysis shall be either the applicable structural code or the ITER Material Properties Handbook. In the case of conflict, the ITER Material Properties Handbook shall take precedence. Materials selection, and use, shall follow the guidelines established in the Materials Assessment Report (MAR). Materials exposed to vacuum shall conform to the ITER Vacuum Handbook. [Ref. 2] Commercial materials shall conform to the applicable standard (e.g., ASTM, JIS, DIN) for the definition of their grade, physical, chemical and electrical properties and related testing. All materials for which a suitable certification from the supplier is not available shall be tested to determine the relevant properties, as part of the procurement. A complete traceability of all the materials including welding materials shall be provided. Halogenated materials (example: insulating materials) shall be forbidden in areas served by the detritiation systems. Exceptions must be approved by the Tritium System and Safety Section Responsible Officers.

Bigelow, Tim S [ORNL

2012-05-01T23:59:59.000Z

365

2005 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE  

U.S. Energy Information Administration (EIA) Indexed Site

Page 1 Page 1 2012 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE Kerosene Line No. Sold directly to consumers for: 1 Residential Use (Non-Farm): * Backup generator * Home heating and cooking * Personal lawn equipment * EXCLUDE: Apartment buildings and Farmhouses 2 Commercial Use: * Apartment building * Bank * Casino * Church * College/School/Institution * Department/Retail store * Environmental clean-up service * Flushing fuel lines * Forestry service * Golf course * Government (Federal, State, local, and district; INCLUDE fuel used in vehicles) * Hazardous waste company * Hospital * Hotel/Motel * Landfill site government owned * Landscaping * Laundry company * Lumber yard that sells the lumber * Medical service * Port Authority/publicly owned port or loading dock

366

CX-006936: Categorical Exclusion Determination | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6: Categorical Exclusion Determination 6: Categorical Exclusion Determination CX-006936: Categorical Exclusion Determination Replace Pole 178 and 13.8 Kilovolt Disconnect Switch in H-Area CX(s) Applied: B1.3 Date: 10/11/2011 Location(s): Aiken, South Carolina Office(s): Environmental Management, Savannah River Operations Office Pole 178 and the H2A/H2B 13.8-kilovolt overhead line disconnect switch were installed in the early 1950s, and are located southwest of Building 292-H. Replacement of both pieces is proposed because the switch malfunctions each time it operates and the pole is bent which presents a safety hazard. Polychlorinated biphenyls (PCB's) are not an issue because there are no liquids/oils associated with the switch. A Radiological Buffer Area (RBA) will be established prior to start of proposed pole removal activities.

367

The Pulse Line Ion Accelerator Concept  

E-Print Network (OSTI)

be modeled as a transmission line with equivalent inductancez , t ) (see Fig. 1), the transmission line equations in thethese elementary transmission line equations are traveling

Briggs, Richard J.

2006-01-01T23:59:59.000Z

368

LINE-ABOVE-GROUND ATTENUATOR  

DOE Patents (OSTI)

The line-above-ground attenuator provides a continuously variable microwave attenuator for a coaxial line that is capable of high attenuation and low insertion loss. The device consists of a short section of the line-above- ground plane type transmission lime, a pair of identical rectangular slabs of lossy material like polytron, whose longitudinal axes are parallel to and indentically spaced away from either side of the line, and a geared mechanism to adjust amd maintain this spaced relationship. This device permits optimum fineness and accuracy of attenuator control which heretofore has been difficult to achieve.

Wilds, R.B.; Ames, J.R.

1957-09-24T23:59:59.000Z

369

The Effect of Shock Stress and Field Strength on Shock-Induced Depoling of Normally Poled PZT 95/5  

Science Conference Proceedings (OSTI)

Shock-induced depoling of the ferroelectric ceramic PZT 95/5 is utilized in a number of pulsed power devices. Several experimental and theoretical efforts are in progress in order to improve numerical simulations of these devices. In this study we have examined the shock response of normally poled PZT 95/5 under uniaxial strain conditions. On each experiment the current produced in an external circuit and the transmitted waveform at a window interface were recorded. The peak electrical field generated within the PZT sample was varied through the choice of external circuit resistance. Shock pressures were varied from 0.6 to 4.6 GPa, and peak electrical fields were varied from 0.2 to 37 kV/cm. For a 2.4 GPa shock and the lowest peak field, a nearly constant current governed simply by the remanent polarization and the shock velocity was recorded. Both decreasing the shock pressure and increasing the electrical field resulted in reduced current generation, indicating a retardation of the depoling kinetics.

CHHABILDAS,LALIT C.; FURNISH,MICHAEL D.; MONTGOMERY,STEPHEN T.; SETCHELL,ROBERT E.

1999-09-01T23:59:59.000Z

370

Applications of Line Profile Analysis  

Science Conference Proceedings (OSTI)

Feb 16, 2010 ... Neutron and X-Ray Studies of Advanced Materials III : Applications of Line Profile ... Science: Robert Von Dreele1; 1APS/Argonne National Laboratory .... using an X-ray synchrotron beam line of the Advanced Photon Source.

371

Software Tackles Production Line Machine ?Cyclic Jitters?  

Science Conference Proceedings (OSTI)

Software Tackles Production Line Machine 'Cyclic ... products, even shutting down assembly lines. ... high-speed data transmission characteristics of ...

2011-07-18T23:59:59.000Z

372

Scientific Computing Kernels on the Cell Processor  

E-Print Network (OSTI)

200 lines of common code. The programming overhead of theselines results in high bandwidth utiliza- tion and su?ciently amortizes the omnipresent 1000 cycle DMA latency overhead,

Williams, Samuel W.; Shalf, John; Oliker, Leonid; Kamil, Shoaib; Husbands, Parry; Yelick, Katherine

2008-01-01T23:59:59.000Z

373

U.S. Department of Energy Categorical Exclusion Determination Form  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Provide Electrical Power for New Tool Storage Building and Portable Crew Shacks Provide Electrical Power for New Tool Storage Building and Portable Crew Shacks Savannah River Site Aiken/Aiken/South Carolina Provide power source for the New Tool Storage Building 217-6H and the Portable Crew Shacks located in the H-Tank Farm area. Provides design for a new transformer bank consisting of (3) three - 13.8kV-208Y/120, 1-Phase, 50 kVA pole mounted transformers to provide such power. A new pole will be placed in line with the existing 13.8kV line, feeder 3B, near pole H3B548. A secondary feeder pole will be placed beside the transformer pole to mount the unistrut built rack, 600 amp disconnect and watthour meter can. There will be a secondary pole placed near the Tool Shed and Crew Shacks to support the overhead secondary feeder cables. The pole being place near the Shed will have a unistrut

374

INTEGRATED VERTICAL AND OVERHEAD DECONTAMINATION (IVOD) SYSTEM  

Science Conference Proceedings (OSTI)

The deactivation and decommissioning of 1200 buildings within the U.S. Department of Energy-Office of Environmental Management complex will require the disposition of a large quantity of contaminated concrete and metal surfaces. It has been estimated that 23 million cubic meters of concrete and over 600,000 tons of metal will need disposition. The disposition of such large quantities of material presents difficulties in the area of decontamination and characterization. The final disposition of this large amount of material will take time and money as well as risk to the D&D work force. A single automated system that would decontaminate and characterize surfaces in one step would not only reduce the schedule and decrease cost during D&D operations but would also protect the D&D workers from unnecessary exposures to contaminated surfaces. This report summarizes the activities performed during FY00 and describes the planned activities for FY01. Accomplishments for FY00 include the following: Development and field-testing of characterization system; Completion of Title III design of deployment platform and decontamination unit; In-house testing of deployment platform and decontamination unit; Completion of system integration design; Identification of deployment site; and Completion of test plan document for deployment of IVOD at Rancho Seco nuclear power facility.

M.A. Ebadian, Ph.D.

2001-01-01T23:59:59.000Z

375

Electric Transmission Line Siting Compact  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electric Transmission Line Siting Compact Electric Transmission Line Siting Compact 1 ______________________________________________________________________________ 2 ARTICLE I 3 PURPOSE 4 5 Siting electric transmission lines across state borders and federal lands is an issue for states, the 6 federal government, transmission utilities, consumers, environmentalists, and other stakeholders. 7 The current, multi-year application review process by separate and equal jurisdictions constitutes 8 a sometimes inefficient and redundant process for transmission companies and complicates the 9 efforts of state and federal policy-makers and other stakeholders to develop more robust 10 economic opportunities, increase grid reliability and security, and ensure the consumers have the 11 lowest cost electricity possible. 12

376

Electrical transmission line diametrical retainer  

DOE Patents (OSTI)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within down hole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to with stand the tension and compression of drill pipe during routine drilling cycles.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT); Fox, Joe (Spanish Fork, UT)

2004-12-14T23:59:59.000Z

377

Pulse shaping with transmission lines  

DOE Patents (OSTI)

A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

Wilcox, R.B.

1985-08-15T23:59:59.000Z

378

Pulse shaping with transmission lines  

DOE Patents (OSTI)

A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

Wilcox, Russell B. (Oakland, CA)

1987-01-01T23:59:59.000Z

379

U.S. Department of Energy Categorical Exclusion Determination Form  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Communication Line Installation Between Manhole F-39 and Building 221-12F Communication Line Installation Between Manhole F-39 and Building 221-12F Savannah River Site Aiken/Aiken/South Carolina MOX Services proposes to install a communication cable beginning at the existing Manhole F-39 and ending at the southwest corner of Building 221-12F. Beginning at the manhole, 4-inch-diameter conduit will be installed in a 25-foot-long, 30-inch-deep trench to the existing Pole F3B059. After conduit installation and cable routing, the conduit will be capped with concrete and the trench will be backfilled with excavated soil. The communication cable will be routed from the manhole to the pole through the conduit, up the pole, and overhead to 221-12F. The area proposed for trenching was surveyed and determined to be free of radiological contamination.

380

Terahertz Quantum-Cascade Transmission-Line Metamaterials  

E-Print Network (OSTI)

Terahertz Transmission-Line Metamaterials . . . . . . .CRLH Transmission Lines . . . . . . . . . . . . . . . .Terahertz CRLH Transmission-Line Metamaterials . . . . . . .

Tavallaee, Amir Ali

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Shape optimization using reflection lines  

Science Conference Proceedings (OSTI)

Many common objects have highly reflective metallic or painted finishes. Their appearance is primarily defined by the distortion the curved shape of the surface introduces in the reflections of surrounding objects. Reflection lines are commonly used ...

E. Tosun; Y. I. Gingold; J. Reisman; D. Zorin

2007-07-01T23:59:59.000Z

382

fault diagnosis of a high voltage transmission line using waveform ...  

E-Print Network (OSTI)

Oct 4, 2013 ... FAULT DIAGNOSIS OF A HIGH VOLTAGE TRANSMISSION LINE USING ... Fault types such as single line to ground, line to line, double line to ...

383

Two terminal line voltage thermostat  

Science Conference Proceedings (OSTI)

A two terminal line voltage thermostat includes a switch which effectively connects line voltage to a heater load. The entire process is controlled by an integrated circuit microcontroller which is powered by a rectified voltage from a transformer secondary connected to a primary which is in series with the heater load. Backup battery power is provided to maintain limited functions of the microcontroller in the event of overall power loss. The microcontroller is programmed to meet the temperature sensing and control requirements specific to a two terminal electric baseboard heating installation. 7 figs.

Stalsberg, K.J.; Ingalls, J.E.; Hoglund, S.R.

1995-10-10T23:59:59.000Z

384

Sympathy for the Sensor Network Debugger  

E-Print Network (OSTI)

tios represent less overhead, so lines towards the left areoverhead correlates with how often nodes send metrics. Each line

Ramanathan, Nithya; Chang, Kevin; Kapur, Rahul; Girod, Lewis; Kohler, Eddie; Estrin, D

2005-01-01T23:59:59.000Z

385

--No Title--  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Install two new steam line poles to replace poles K164 and K165 in 105-K Area. Excavations for new poles will be as close possible to the existing poles (2 to 4 feet). Old poles...

386

Coiled transmission line pulse generators  

DOE Patents (OSTI)

Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

McDonald, Kenneth Fox (Columbia, MO)

2010-11-09T23:59:59.000Z

387

Analysis of the Use of Wind Energy to Supplement the Power Needs at McMurdo Station and Amundsen-Scott South Pole Station, Antarctica (Poster)  

DOE Green Energy (OSTI)

This poster summarizes the analysis of the inclusion of wind-driven power generation technology into the existing diesel power plants at two U.S. Antarctic research stations, McMurdo and Amundsen-Scott South Pole Station. Staff at the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the analysis. Available data were obtained on the wind resources, power plant conditions, load, and component cost. We then used NREL's Hybrid2 power system modeling software to analyze the potential and cost of using wind turbine generators at the two aforementioned facilities.

Baring-Gould, E. I.; Robichaud, R.; McLain, K.

2005-05-01T23:59:59.000Z

388

MATERIALS DEGRADATION ANALYSIS AND DEVELOPMENT TO ENABLE ULTRA LOW COST, WEB-PROCESSED WHITE P-OLED FOR SSL  

SciTech Connect

Progress over Phase II of DE-FG02-07ER86293 'Materials Degradation Analysis and Development to Enable Ultra Low Cost, Web-Processed White P-OLED for SSL' was initially rapid in terms of device performance improvements. We exceeded our device luminance lifetime goals for printed flexible white OLEDs as laid out in our project proposal. Our Phase II performance target was to demonstrate >1500 hours luminance lifetime at 100 Cd/m2 from a printed flexible device. We now have R&D devices well in excess of 8000 hrs lifetime at 100 Cd/m2, tested in air. We also were able to produce devices which met the voltage target of >1500 hours below 15V operation. After completing the initial performance milestones, we went on to focus on color-related degradation issues which were cited as important to commercialization of the technology by our manufacturing partners. We also put additional focus on cathode work as the active material development that occurred over the STTR time period required an adaptation of the cathode from the original cathode formulations which were developed based on previous generation active layer materials. We were able to improve compatibility of the cathode with some of the newer generation active layer materials and improve device yield and voltage behavior. An additional objective of the initial Phase II was to further develop the underlying manufacturing technology and real-life product specifications. This is a key requirement that must be met to ensure eventual commercialization of this DOE-funded technology. The link between commercial investment for full commercialization and R&D efforts in OLED solid State Lighting is often a large one. Add-Vision's lower cost, printed OLED manufacturing approach is an attraction, but close engagement with manufacturing partners and addressing customer specifications is a very important link. Manufacturing technology encompasses development of moisture reduction encapsulation technology, improved cost performance, and reductions in operating voltage through thinner and higher uniformity active device layers. We have now installed a pilot encapsulation system at AVI for controlled, high throughput lamination encapsulation of flexible OLEDs in a novel process. Along with this, we have developed, with our materials supply partners, adhesives, barrier films and other encapsulation materials and we are showing total air product lifetimes in the 2-4 years range from a process consistent with our throughput goals of {approx}1M device per month ({approx}30,000 sq. ft. of processed OLEDs). Within the last year of the project, we have been working to introduce the manufacturing improvements made in our LEP deposition and annealing process to our commercial partners. Based on the success of this, a pilot scale-up program was begun. During this process, Add-Vision was acquired by a strategic partner, in no small part, because of the promise of future success of the technology as evidenced by our commercial partners pilot scale-up plans. Overall, the performance, manufacturing and product work in this project has been successful. Additional analysis and device work at LBL has also shown a unique adhesion change with device bias stressing which may result from active layer polymer cross-linking during bias stressing of device. It was shown that even small bias stresses, as a fraction of a full device lifetime stress period, result in measurable chemical change in the device. Further work needs to be conducted to fully understand the chemical nature of this interaction. Elucidation of this effect would enable doped OLED formulation to be engineered to suppress this effect and further extend lifetimes and reduce voltage climb.

DR. DEVIN MACKENZIE

2011-12-13T23:59:59.000Z

389

Zigzag Survey Designs in Line Transect Sampling  

E-Print Network (OSTI)

survey lines are frequently used in shipboard and aerial line transect surveys of animal populations; Systematic designs; Zigzag designs. 1. INTRODUCTION Shipboard and aerial line transect surveys are widelyZigzag Survey Designs in Line Transect Sampling Samantha STRINDBERG and Stephen T. BUCKLAND Zigzag

Buckland, Steve

390

Beam line windows at LAMPF  

Science Conference Proceedings (OSTI)

The A-6 main beam-line window at LAMPF separates the vacuum of the main beam line from the isotope production station, proton irradiation ports, and the beam stop, which operate in air. This window must withstand the design beam current of 1 mA at 800 MeV for periods of at least 3000 hours without failure. The window is water cooled and must be strong enough to withstand the 2.1 MPa (300 psig) cooling water pressure, as well as beam-induced thermal stresses. Two designs have been used to meet these goals, a stepped-plate window and a hemispherical window, both made from a precipitation-hardened nickel base alloy, Alloy 718. Calculations of the temperatures and stresses in each of these windows are presented.

Brown, R.D.; Grisham, D.L.; Lambert, J.E.

1985-01-01T23:59:59.000Z

391

BOREAS Survey On-Line  

NLE Websites -- All DOE Office Websites (Extended Search)

FF33"> FF33"> BOREAS Survey On-Line To improve the BOREAS and BOREAS Follow-On data sets and to meet users' needs, we are conducting a survey. The BOREAS and BOREAS Follow-On data sets continue to be important products at the ORNL DAAC. To date we have provided over 8,000 data products from these projects to nearly 1,500 users. We invite you to fill out this survey, identifying any problems you had with the data and documentation or any difficulties you experienced in finding and acquiring the data sets. Information you provide will enable us to address problems that need attention. It will also help us determine which aspects of the BOREAS and BOREAS Follow-On information need to be expanded. You can complete the survey at the BOREAS Home Page. After you complete the on-line survey, submit your answers to the ORNL

392

Managing Transmission Line Wood Structures  

Science Conference Proceedings (OSTI)

Transmission and distribution infrastructures throughout the world are aging. As such, inspection, assessment, and maintenance of existing facilities have become increasingly important topics. This valuable reference provides an in-depth look at all facets of an inspection, assessment, and maintenance program for transmission line wood structures to help utilities develop and refine individual maintenance programs. The report is part of a broader multi-year effort by EPRI to develop a comprehensive handb...

2006-09-28T23:59:59.000Z

393

Analysis of the Use of Wind Energy to Supplement the Power Needs at McMurdo Station and Amundsen-Scott South Pole Station, Antarctica  

DOE Green Energy (OSTI)

This report summarizes an analysis of the inclusion of wind-driven power generation technology into the existing diesel power plants at two U.S. Antarctic research stations, McMurdo and Amundsen-Scott South Pole Station. Staff at the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the analysis. Raytheon Polar Services, which currently holds the private sector support contract for the two research stations, was a major contributor to this report. To conduct the analysis, available data were obtained on the wind resources, power plant conditions, load, and component cost. Whenever possible, we validated the information. We then used NREL's Hybrid2 power system modeling software to analyze the potential and cost of using wind turbine generators at the two aforementioned facilities. Unfortunately, the power systems and energy allocations at McMurdo and South Pole Station are being redeveloped, so it is not possible to validate future fuel use. This report is an initial assessment of the potential use of wind energy and should be followed by further, more detailed analysis if this option is to be considered further.

Baring-Gould, I.; Robichaud, R.; McLain, K.

2005-05-01T23:59:59.000Z

394

Nucleon pole contributions in $J/?\\to N \\bar{N} ?$, $p \\bar{p} ?$, $p \\bar{p} ?^{\\prime}$ and $p \\bar{p} ?$ decays  

E-Print Network (OSTI)

Nucleon pole contributions in $J/\\psi \\to N \\bar N \\pi$, $p \\bar p \\eta$, $p \\bar p \\eta^{\\prime}$ and $p \\bar{p} \\omega$ decays are re-studied. Different contributions due to PS-PS and PS-PV couplings in the $\\pi$-N interaction and the effects of $NN\\pi$ form factors are investigated in the $J/\\psi \\to N \\bar N \\pi$ decay channel. It is found that when the ratio of $|F_0| /|F_M|$ takes small value, without considering the $NN\\pi$ form factor, the difference between PS-PS and PS-PV couplings are negligible. However, when the $NN\\pi$ form factor is included, this difference is greatly enlarged. The resultant decay widths are sensitive to the form factors. As a conclusion, the nucleon-pole contribution as a background is important in the $J/\\psi\\to N\\bar{N}\\pi$ decay and must be accounted. In the $J/\\psi\\to N\\bar{N}\\eta$ and $N\\bar{N}\\eta'$ decays, its contribution is less than 0.1% of the data. In the $J/\\psi\\to N\\bar{N}\\omega$ decay, it provides rather important contribution without considering form factors. But the contribution is suppressed greatly when adding the off-shell form factors. Comparing these results with data would help us to select a proper form factor for such kind of decay.

Wei-Hong Liang; Peng-Nian Shen; Bing-Song Zou; Amand Faessler

2004-04-08T23:59:59.000Z

395

THE FIRST PUBLIC RELEASE OF SOUTH POLE TELESCOPE DATA: MAPS OF A 95 deg{sup 2} FIELD FROM 2008 OBSERVATIONS  

SciTech Connect

The South Pole Telescope (SPT) has nearly completed a 2500 deg{sup 2} survey of the southern sky in three frequency bands. Here, we present the first public release of SPT maps and associated data products. We present arcminute-resolution maps at 150 GHz and 220 GHz of an approximately 95 deg{sup 2} field centered at R.A. 82.{sup 0}7, decl. -55 Degree-Sign . The field was observed to a depth of approximately 17 {mu}K arcmin at 150 GHz and 41 {mu}K arcmin at 220 GHz during the 2008 austral winter season. Two variations on map filtering and map projection are presented, one tailored for producing catalogs of galaxy clusters detected through their Sunyaev-Zel'dovich effect signature and one tailored for producing catalogs of emissive sources. We describe the data processing pipeline, and we present instrument response functions, filter transfer functions, and map noise properties. All data products described in this paper are available for download at http://pole.uchicago.edu/public/data/maps/ra5h30dec-55 and from the NASA Legacy Archive for Microwave Background Data Analysis server. This is the first step in the eventual release of data from the full 2500 deg{sup 2} SPT survey.

Schaffer, K. K.; Crawford, T. M.; Benson, B. A.; Bleem, L. E.; Carlstrom, J. E.; Chang, C. L.; Crites, A. T.; Hoover, S.; Keisler, R. [Kavli Institute for Cosmological Physics, University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Aird, K. A.; Hrubes, J. D. [University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Cho, H. M. [NIST Quantum Devices Group, 325 Broadway Mailcode 817.03, Boulder, CO 80305 (United States); De Haan, T.; Dobbs, M. A.; Holder, G. P. [Department of Physics, McGill University, 3600 Rue University, Montreal, Quebec H3A 2T8 (Canada); George, E. M.; Holzapfel, W. L. [Department of Physics, University of California, Berkeley, CA 94720 (United States); Halverson, N. W. [Department of Astrophysical and Planetary Sciences and Department of Physics, University of Colorado, Boulder, CO 80309 (United States); Joy, M. [Department of Space Science, VP62, NASA Marshall Space Flight Center, Huntsville, AL 35812 (United States); Knox, L., E-mail: kschaf2@saic.edu [Department of Physics, University of California, One Shields Avenue, Davis, CA 95616 (United States); and others

2011-12-10T23:59:59.000Z

396

In-Line Thermoelectric Module  

DOE Patents (OSTI)

A thermoelectric module with a plurality of electricity generating units each having a first end and a second end, the units being arranged first end to second end along an-in-line axis. Each unit includes first and second elements each made of a thermoelectric material, an electrically conductive hot member arranged to heat one side of the first element, and an electrically conductive cold member arranged to cool another side of the first element and to cool one side of the second element. The hot member, the first element, the cold member and the second element are supported in a fixture, are electrically connected respectively to provide an electricity generating unit, and are arranged respectively in positions along the in-line axis. The individual components of each generating unit and the respective generating units are clamped in their in-line positions by a loading bolt at one end of the fixture and a stop wall at the other end of the fixture. The hot members may have a T-shape and the cold members an hourglass shape to facilitate heat transfer. The direction of heat transfer through the hot members may be perpendicular to the direction of heat transfer through the cold members, and both of these heat transfer directions maybe perpendicular to the direction-of current flow through the module.

Pento, Robert; Marks, James E.; Staffanson, Clifford D.

1998-07-28T23:59:59.000Z

397

In-line thermoelectric module  

DOE Patents (OSTI)

A thermoelectric module with a plurality of electricity generating units each having a first end and a second end, the units being arranged first end to second end along an in-line axis. Each unit includes first and second elements each made of a thermoelectric material, an electrically conductive hot member arranged to heat one side of the first element, and an electrically conductive cold member arranged to cool another side of the first element and to cool one side of the second element. The hot member, the first element, the cold member and the second element are supported in a fixture, are electrically connected respectively to provide an electricity generating unit, and are arranged respectively in positions along the in-line axis. The individual components of each generating unit and the respective generating units are clamped in their in-line positions by a loading bolt at one end of the fixture and a stop wall at the other end of the fixture. The hot members may have a T-shape and the cold members an hourglass shape to facilitate heat transfer. The direction of heat transfer through the hot members may be perpendicular to the direction of heat transfer through the cold members, and both of these heat transfer directions may be perpendicular to the direction of current flow through the module.

Pento, Robert (Algonquin, IL); Marks, James E. (Glenville, NY); Staffanson, Clifford D. (S. Glens Falls, NY)

2000-01-01T23:59:59.000Z

398

THE ROLE OF THE INVARIANT LINE IN THE SEARCH FOR AN OPTIMUM INTERPHASE BOUNDARY BY O-LATTICE THEORY  

E-Print Network (OSTI)

3-jrJdcx pole~;) and hcp lattice (4-index poles). CoincidentINTERPHASE BOUNDARY BY 0-LATTICE THEORY U. Dahmen NovemberInterphase Boundary by 0-Lattice Tl1eory rmaly~;Pd In a

Dahmen, U.

2013-01-01T23:59:59.000Z

399

Overview: Physical & DataLink LayersOverview: Physical & DataLink Layers How are frames assembled and transmitted ?  

E-Print Network (OSTI)

is SONET?What is SONET? q Synchronous optical network q Standard for digital optical transmission (bit pipe Section Overhead 3 Rows Path Overhead 90 Columns Synchronous Payload Envelope 9 Rows Line Overhead 6 Rows Line Overhead 6 Rows #12;Raj JainThe Ohio State University 13 Location of SPE in STS-1Location of SPE

Murphy, John

400

On-chip interconnect architectures : perspectives of layout, circuits, and systems  

E-Print Network (OSTI)

dissipation overhead of the transmission line shunts is onlyk vias aligned in a line, the track overhead on the middleoverhead = 9 Figure II.17: Via tunnels with vias aligned in a line

Chen, Hongyu

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Large-Scale Variability Characterization and Robust Design Techniques for Nanoscale SRAM  

E-Print Network (OSTI)

The overall area overhead of the bit-line switch network inlow overhead, the proposed direct bit- line characterizationoverhead can be further reduced with an optimized layout of the bit-line

Guo, Zheng

2009-01-01T23:59:59.000Z

402

Checking the Data Sharing Strategies of Concurrent Systems Level Code  

E-Print Network (OSTI)

lines of applica- tion and benchmark code, and observe manageable overheadssmall (about 400k lines) Linux kernel. Overhead incurred byover 500k lines of code. Runtime overhead av- eraged 11%

Anderson, Zachary Ryan

2010-01-01T23:59:59.000Z

403

Environmental Assessment for Central Power and Light Company`s proposed Military Highway-CFE tie 138/69-kV transmission line project Brownsville, Cameron County, Texas  

SciTech Connect

Central Power and Light Company (CPL) intends to upgrade its existing transmission line ties with the Commision Federal de Electricidad (CFE) system in Mexico. CPL currently has a single 69-kilovolt (kV) transmission line in the Brownsville area which connects CPL`s system with the system of CFE. This existing line runs between the Brownsville Switching Station, located on Laredo Road in Brownsville, Cameron County, Texas, and an existing CFE 69-kV line at the Rusteberg Bend of the Rio Grande in Cameron County. Under current conditions of need, the existing 69-kV line does not possess sufficient capability to engage in appropriate power exchanges. Therefore, CPL is proposing to build a new line to link up with CFE. This proposed line would be a double-circuit line, which would (1) continue (on a slightly relocated route) the existing 69-kV tie from CPL`s Brownsville Switching Station to CFE`s facilities, and (2) add a 138-kV tie from the Military Highway Substation, located on Military Highway (US Highway 281), to CFE`s facilities. The proposed 138/69-kV line, which will be constructed and operated by CPL, will be built primarily on steel single-pole structures within an average 60-foot (ft) wide right-of-way (ROW). It will be approximately 6900--9200 ft (1.3--1.7 miles) in length, depending on the alternative route constructed.

1992-04-01T23:59:59.000Z

404

Tropical Squall Lines of the Arizona Monsoon  

Science Conference Proceedings (OSTI)

Squall lines possessing nearly all the characteristics of tropical squall lines occasionally develop during the summer monsoon over southern Arizona and northwestern Mexico. Initial thunderstorm formation is over the Continental Divide in the ...

Walter P. Smith; Robert L. Gall

1989-07-01T23:59:59.000Z

405

Squall-Line Intensification via Hydrometeor Recirculation  

Science Conference Proceedings (OSTI)

Many studies have demonstrated the intimate connection between microphysics and deep moist convection, especially for squall lines via cold pool pathways. The present study examines four numerically simulated idealized squall lines using the ...

Robert B. Seigel; Susan C. van den Heever

2013-07-01T23:59:59.000Z

406

A Computer Package for Transmission Line Analysis  

Science Conference Proceedings (OSTI)

A computer program, LIGNE, has been developed as a comprehensive teaching aid for the section on transmission line theory in an electromagnetics course. The program assists the student in the analysis of transmission lines, enabling him to quickly assess ...

Georges-Andre Chaudron; Manfred Nachman

1987-11-01T23:59:59.000Z

407

Potential Vorticity Anomalies Associated with Squall Lines  

Science Conference Proceedings (OSTI)

This study involves observations and model simulations of potential vorticity anomalies in the wake of midlatitude squall lines. Using data from the Oklahoma–Kansas PRE-STORM experiment, we analyze potential vorticity fields near two squall lines—...

Rolf F. A. Hertenstein; Wayne H. Schubert

1991-07-01T23:59:59.000Z

408

Methods of Using Existing Wire Lines (power lines, phone lines, internet lines) for Totally Secure Classical Communication Utilizing Kirchoff's Law and Johnson-like Noise  

E-Print Network (OSTI)

We outline some general solutions to use already existing and currently used wire lines, such as power lines, phone lines, internet lines, etc, for the unconditionally secure communication method based on Kirchoff's Law and Johnson-like Noise (KLJN). Two different methods are shown. One is based on filters used at single wires and the other one utilizes a common mode voltage superimposed on a three-phase powerline.

Laszlo B. Kish

2006-10-02T23:59:59.000Z

409

Capillary electrophoresis-fluorescence line narrowing system (CE-FLNS) for on-line structural characterization  

DOE Patents (OSTI)

Capillary electrophoresis (CE) is interfaced with low temperature fluorescence line-narrowing (FLN) spectroscopy for on-line structural characterization of separated molecular analytes.

Jankowiak, Ryszard J. (Ames, IA); Small, Gerald J. (Ames, IA); Shields, Peter A. (Reading, MA)

1999-04-27T23:59:59.000Z

410

Practical pairwise testing for software product lines  

Science Conference Proceedings (OSTI)

One key challenge for software product lines is efficiently managing variability throughout their lifecycle. In this paper, we address the problem of variability in software product lines testing. We (1) identify a set of issues that must be addressed ... Keywords: feature modelling, software product lines, variability management

Dusica Marijan, Arnaud Gotlieb, Sagar Sen, Aymeric Hervieu

2013-08-01T23:59:59.000Z

411

Visualizing DIII-D Tokamak magnetic field lines  

Science Conference Proceedings (OSTI)

Keywords: graphics hardware, haloed lines, illuminated lines, interactive visualization, magentic field, plasma physics, tokamak

Greg Schussman; Kwan-Liu Ma; David Schissel; Todd Evans

2000-10-01T23:59:59.000Z

412

Neutron Drip-Line Topography  

Science Conference Proceedings (OSTI)

The development of microscopic mass models is a crucial ingredient for the understanding of how most of the elements of our world were fabricated. Confidence in drip-line predictions of such models requires their comparison with new mass data for nuclides far from stability. We combine theory and experiment using results that are state of the art: the latest mass measurements from the Penning-trap spectrometer ISOLTRAP at CERN-ISOLDE are used to confront the predictions of the latest Skyrme-Hartree-Fock-Bogoliubov (HFB) microscopic mass models. In addition, we compare the new data to predictions of other types of mass models and the extrapolative behavior of the various models is analyzed to highlight topographical trends along the shores of the nuclear chart.

Ramirez, E. Minaya; Audi, G.; Lunney, D.; Naimi, S. [Centre de Spectrometrie Nucleaire et de Spectrometrie de Masse, Universite Paris Sud, Orsay (France); Beck, D.; Herfurth, F. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Blaum, K.; Borgmann, C.; George, S.; Kellerbauer, A. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Boehm, Ch.; Neidherr, D. [Institut fuer Physik, Johannes-Gutenberg-Universitaet, Mainz (Germany); Breitenfeldt, M.; Rosenbusch, M.; Schweikhard, L. [Institut fuer Physik, Ernst-Moritz-Arndt-Universitaet, Greifswald (Germany); Chamel, N.; Goriely, S. [Institut d'Astronomie et d'Astrophysique, Universite Libre de Bruxelles (Belgium); Herlert, A.; Kowalska, M. [Physics Department, Centre European de Recherche Nucleaire, Geneva (Switzerland); Pearson, J. M. [Department of Physics, Universite de Montreal, Montreal, Quebec (Canada)] (and others)

2009-08-26T23:59:59.000Z

413

Gamma-Ray Burst Lines  

E-Print Network (OSTI)

The evidence for spectral features in gamma-ray bursts is summarized. As a guide for evaluating the evidence, the properties of gamma-ray detectors and the methods of analyzing gamma-ray spectra are reviewed. In the 1980's, observations indicated that absorption features below 100 keV were present in a large fraction of bright gamma-ray bursts. There were also reports of emission features around 400 keV. During the 1990's the situation has become much less clear. A small fraction of bursts observed with BATSE have statistically significant low-energy features, but the reality of the features is suspect because in several cases the data of the BATSE detectors appear to be inconsistent. Furthermore, most of the possible features appear in emission rather than the expected absorption. Analysis of data from other instruments has either not been finalized or has not detected lines.

Michael S. Briggs

1999-10-20T23:59:59.000Z

414

Superconducting transmission line particle detector  

DOE Patents (OSTI)

A microvertex particle detector for use in a high energy physic collider including a plurality of parallel superconducting thin film strips separated from a superconducting ground plane by an insulating layer to form a plurality of superconducting waveguides. The microvertex particle detector indicates passage of a charged subatomic particle by measuring a voltage pulse measured across a superconducting waveguide caused by the transition of the superconducting thin film strip from a superconducting to a non- superconducting state in response to the passage of a charged particle. A plurality of superconducting thin film strips in two orthogonal planes plus the slow electromagnetic wave propagating in a superconducting transmission line are used to resolve N/sup 2/ ambiguity of charged particle events. 6 figs.

Gray, K.E.

1988-07-28T23:59:59.000Z

415

Magnetically insulated transmission line oscillator  

DOE Patents (OSTI)

A magnetically insulated transmission line oscillator employs self-generated magnetic fields to generate microwave energy. An anode of the oscillator includes slow-wave structures which are formed of a plurality of thin conductive vanes defining cavities therebetween, and a gap is formed between the anode and a cathode of the oscillator. In response to a pulsed voltage applied to the anode and cathode, self-generated magnetic fields arfe produced in a cross-field orientation with respect to the orientation of the electric field between the anode and the cathode. The cross-field magnetic fields insulate the flow of electrons in the gap and confine the flow of electrons within the gap.

Bacon, Larry D. (Albuquerque, NM); Ballard, William P. (Albuquerque, NM); Clark, M. Collins (Albuquerque, NM); Marder, Barry M. (Albuquerque, NM)

1988-01-01T23:59:59.000Z

416

Superconducting transmission line particle detector  

DOE Patents (OSTI)

A microvertex particle detector for use in a high energy physic collider including a plurality of parallel superconducting thin film strips separated from a superconducting ground plane by an insulating layer to form a plurality of superconducting waveguides. The microvertex particle detector indicates passage of a charged subatomic particle by measuring a voltage pulse measured across a superconducting waveguide caused by the transition of the superconducting thin film strip from a superconducting to a non-superconducting state in response to the passage of a charged particle. A plurality of superconducting thin film strips in two orthogonal planes plus the slow electromagnetic wave propogating in a superconducting transmission line are used to resolve N.sup.2 ambiguity of charged particle events.

Gray, Kenneth E. (Naperville, IL)

1989-01-01T23:59:59.000Z

417

Power Line Calculator for DOS  

Science Conference Proceedings (OSTI)

The Power Line Calculator (PLC) for DOS, version 1.0, is a program that describes the electrical characteristics of a transmission or distribution system given user-defined input. This input may consist of a combination of operating currents and phases, symmetric components, power factor, and real or reactive power. The program also allows the user to designate whether currents are present on the system neutral or in the ground. The PLC assumes that any value entered by the user remains fixed (e.g., phase current, power factor), and for underdetermined systems, basic default assumptions are incorporated: the power factor is held at or near 1.0, the net phase current is kept at or near zero, and the phase conductor currents are kept balanced. The program operates under PC/MS-DOS version 3.3 or later, and the output is available in both tabular and graphic formats.

Silva, J.M. (Enertech Consultants, Campbell, CA (United States))

1992-11-01T23:59:59.000Z

418

Magnetically insulated transmission line oscillator  

DOE Patents (OSTI)

A magnetically insulated transmission line oscillator employs self-generated magnetic fields to generate microwave energy. An anode of the oscillator includes slow-wave structures which are formed of a plurality of thin conductive vanes defining cavities therebetween, and a gap is formed between the anode and a cathode of the oscillator. In response to a pulsed voltage applied to the anode and cathode, self-generated magnetic fields are produced in a cross-field orientation with respect to the orientation of the electric field between the anode and the cathode. The cross-field magnetic fields insulate the flow of electrons in the gap and confine the flow of electrons within the gap. 11 figs.

Bacon, L.D.; Ballard, W.P.; Clark, M.C.; Marder, B.M.

1987-05-19T23:59:59.000Z

419

On-line transformer monitoring  

Science Conference Proceedings (OSTI)

There are presently many different approaches to transformer monitoring, either on the market or under development. There are also, many different opinions about how on-line monitoring should be accomplished. On the one hand, efforts are being made to develop expert systems that monitor all transformer parameters and generate an estimate of overall transformer condition. On the other hand, a large number of transformer monitors, designed to monitor one or two specific parameters are already on the market. Another important factor to consider in choosing a monitor is who receives the information and how it is transmitted. The ultimate transformer monitor should feed into the supervisory control and data acquisition (Scada) system. This paper discusses the various aspects of this issue including asset protection, cost control, dissolved gases, pinpointing bad bushings and current transformers, hot spot measurement partial discharge, and water-in-oil measurements. 10 figs.

NONE

1995-10-01T23:59:59.000Z

420

Separation of magnetic field lines  

SciTech Connect

The field lines of magnetic fields that depend on three spatial coordinates are shown to have a fundamentally different behavior from those that depend on two coordinates. Unlike two-coordinate cases, a flux tube in a magnetic field that depends on all three spatial coordinates that has a circular cross section at one location along the tube characteristically has a highly distorted cross section at other locations. In an ideal evolution of a magnetic field, the current densities typically increase. Crudely stated, if the current densities increase by a factor {sigma}, the ratio of the long to the short distance across a cross section of a flux tube characteristically increases by e{sup 2{sigma}}, and the ratio of the longer distance to the initial radius increases as e{sup {sigma}}. Electron inertia prevents a plasma from isolating two magnetic field structures on a distance scale shorter than c/{omega}{sub pe}, which is about 10 cm in the solar corona, and reconnection must be triggered if {sigma} becomes sufficiently large. The radius of the sun, R{sub Circled-Dot-Operator }=7 Multiplication-Sign 10{sup 10}cm is about e{sup 23} times larger, so when {sigma} Greater-Than-Or-Equivalent-To 23, two lines separated by c/{omega}{sub pe} at one location can be separated by the full scale of any magnetic structures in the corona at another. The conditions for achieving a large exponentiation, {sigma}, are derived, and the importance of exponentiation is discussed.

Boozer, Allen H. [Department of Applied Physics and Applied Mathematics, Columbia University, New York, New York 10027 (United States)

2012-11-15T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Marine surveys aid gas line  

Science Conference Proceedings (OSTI)

Detailed marine surveys helped B.C. Hydro, a Canadian gas distribution utility, select the submarine route portion of the proposed Vancouver Island gas pipeline system. In 1984, after a series of government hearings, B.C. Hydro's route selection was adopted by the British Columbia Provincial Government. Vancouver Island is the last major population center in Western Canada not supplied with natural gas. In fact, studies of a gas pipeline to the island have been carried out periodically over the past 30 years. But until recently, all schemes have appeared unattractive because of a combination of technical, economic, and political factors. The proposed Vancouver Island project which is awaiting funding, consists of a dual 52.7-km marine transmission pipeline link from the mainland to the island. Diameter of this portion of line will be either 12 of 16-in. Also, part of the proposed system will be an 18.5-km line on the mainland, a 280-km transmission pipeline on the island, compression facilities, and distribution systems in the major population centers. Diameters for the land portions will vary between 6 and 24 in. For several months in late 1983 and early 1984, the project was the subject of public hearings held by the British Columbia Utilities Commission. This process was complicated when two companies applied to construct and operate the marine pipeline link to the island using completely different routes and techniques. In July 1984, the commission recommended to the Provincial Government that B.C. Hydro's proposal for the marine pipeline be accepted. It further recommended that an Energy Project Certificate for construction of the pipeline link to the island be awarded to B.C. Hydro. The recommendation was accepted by the Provincial Government and the project now awaits a funding agreement between the Federal and Provincial Governments.

Park, C.A.; Baines, F.A. Koenig, H.L.

1986-05-05T23:59:59.000Z

422

Computing criticality of lines in power systems  

E-Print Network (OSTI)

Abstract — We propose a computationally efficient method based on nonlinear optimization to identify critical lines, failure of which can cause severe blackouts. Our method computes criticality measure for all lines at a time, as opposed to detecting a single vulnerability, providing a global view of the system. This information on criticality of lines can be used to identify multiple contingencies by selectively exploring multiple combinations of broken lines. The effectiveness of our method is demonstrated on the IEEE 30 and 118 bus systems, where we can very quickly detect the most critical lines in the system and identify severe multiple contingencies. I.

Ali P?nar; Adam Reichert; Bernard Lesieutre

2007-01-01T23:59:59.000Z

423

Line Extension Alternatives | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Line Extension Alternatives Line Extension Alternatives Line Extension Alternatives < Back Eligibility Utility Savings Category Energy Sources Buying & Making Electricity Solar Wind Program Info State Vermont Program Type Line Extension Analysis Provider Vermont Department of Public Service The Public Service Board (PSB) of Vermont developed rules regarding utility line extension requests. While the majority of the rules focus on the procedure followed (and associated fees) for the actual line extensions, the PSB also included a provision that requires the electric utilities to provide written information to customers about off-grid electricity generators as an alternative to line extensions. The PSB recognized that in many cases off-grid electricity generators are less expensive than

424

Line Extension Analysis | Open Energy Information  

Open Energy Info (EERE)

Line Extension Analysis Line Extension Analysis Jump to: navigation, search When a prospective electric customer requests service for a home or facility that is not currently serviced by the electric grid, the customer usually must pay a distance-based fee for the cost of extending power lines to the home or facility. In many cases, it is cheaper to use an on-site renewable energy system to meet a prospective customer’s electricity needs. Certain states require utilities to provide information regarding renewable energy options when prospective customers request a line extension. [1] Line Extension Analysis Incentives CSV (rows 1 - 12) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Authorization of Line Extension (Nebraska) Line Extension Analysis Nebraska Agricultural

425

St-Onge, G., and J.S. Stoner. 2011. Paleomagnetism near the North Magnetic Pole: A unique vantage point for understanding the dynamics of the geomagnetic field and its secular  

E-Print Network (OSTI)

vantage point for understanding the dynamics of the geomagnetic field and its secular variationsOmagNeTiSm Near The NOrTh magNeTiC pOle a unique Vantage point for understanding the Dynamics of the geomagnetic Field and its Secular Variations abSTraCT. Along with the dramatic decrease in global geomagnetic field

426

Final joint environmental assessment for the construction and routine operation of a 12-kilovolt (KV) overhead powerline right-of-way, and formal authorization for a 10-inch and 8-inch fresh water pipeline right-of-way, Naval Petroleum Reserve No. 1, Kern County, California  

SciTech Connect

The purpose and need of the proposed action, which is the installation of an overhead powerline extension from an Naval Petroleum Reserve No. 1 (NPR-1) power source to the WKWD Station A, is to significantly reduce NPR-1`s overall utility costs. While the proposed action is independently justified on its own merits and is not tied to the proposed NPR-1 Cogeneration Facility, the proposed action would enable DOE to tie the NPR-1 fresh water pumps at Station A into the existing NPR-1 electrical distribution system. With the completion of the cogeneration facility in late 1994 or early 1995, the proposed action would save additional utility costs. This report deals with the environmental impacts of the construction of the powerline and the water pipeline. In addition, information is given about property rights and attaining permission to cross the property of proposed affected owners.

1994-10-01T23:59:59.000Z

427

Single transmission line data acquisition system  

DOE Patents (OSTI)

A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

Fasching, George E. (Morgantown, WV)

1984-01-01T23:59:59.000Z

428

NSLS-II Transport Line Progress  

SciTech Connect

The National Synchrotron Light Source II (NSLS-II) is a state-of-the-art 3-GeV third generation light source currently under construction at Brookhaven National Laboratory. The NSLS-II injection system consists of a 200 MeV linac, a 3-GeV booster synchrotron and associated transfer lines. The first part of the Linac to Booster Transport (LBT) line has been installed for linac commissioning. This part includes all components necessary to commission the NSLS-II linac. The second part of this transport line is undergoing installation. Initial results of hardware commissioning will be discussed. The Booster to Storage Ring (BSR) transport line underwent a design review. The first part of the BSR transport line, consisting of all components necessary to commission the booster will be installed in 2012 for booster commissioning. We report on the final design of the BSR line along with the plan to commission the booster.

Fliller R. P.; Wahl, W.; Anderson, A.; Benish, B.; DeBoer, W.; Ganetis, G.; Heese, R.; Hseuh, H.-C.; Hu, J.-P.; Johanson, M.P.; Kosciuk, B.N.; Padrazo, D.; Roy, K.; Shaftan, T.; Singh, O.; Tuozzolo, J.; Wang, G.

2012-05-20T23:59:59.000Z

429

Magnetic Materials for Broadband Transmission Line  

E-Print Network (OSTI)

The author’s series of articles on broadband transmission line transformers (TLTs) concludes with these notes on magnetic materials and the properties that are important for best performance Ferrite and iron powder magnetic materials were developed to support a wide range of components, including inductors, EMI suppressors, conventional transformers and transmission line transformers (TLTs). This article deals with transmission line transformers, presenting the observations and conclusions of the author, reached after extensive experimental research into the behavior and performance of these devices in broadband applications. Figure 1 · The three transformers used in comparing the performance of the autotransformer and the transmission line transformer. At the top left is an autotransformer; at the top right is the transmission line transformer, while at the bottom is a transmission line transformer without a ferrite core. All transformers had a total of 10 turns.

Jerry Sevick

2005-01-01T23:59:59.000Z

430

Data:62ae1d6e-7810-4ed8-b75a-5a2af752d571 | Open Energy Information  

Open Energy Info (EERE)

ae1d6e-7810-4ed8-b75a-5a2af752d571 ae1d6e-7810-4ed8-b75a-5a2af752d571 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Tipmont Rural Elec Member Corp Effective date: 2010/01/22 End date if known: Rate name: SCHEDULE SL: 400W Mercury Vapor Flood Overhead service(metered) Sector: Lighting Description: 1. AVAILABILITY Available for overhead street lighting in the towns of Battle Ground, Linden, New Richmond, Wingate, and Romney, in accordance with contracts which may be signed by each municipality or by the sponsoring organization. 2. CHARACTER OF SERVICE Tipmont Rural Electric Membership Corporation (REMC) will furnish all necessary equipment to operate and maintain an overhead street lighting system in conjunction with and as a part of its general overhead electric distribution system, and the REMC will furnish all electric power required for the purpose of furnishing overhead street lighting service to the member. The municipalities shall pay all installation, labor and material of additional poles and conductor required to extend existing lines to the proposed street light locations. The lighting hours for the said overhead street lighting system shall be on a "dusk to dawn" schedule, which provides that lamps are to be lighted approximately one-half hour after sunset until approximately one-half hour before sunrise each day in the year.

431

Data:C19e6de5-22ac-44c3-a62f-1e08e5070be5 | Open Energy Information  

Open Energy Info (EERE)

e6de5-22ac-44c3-a62f-1e08e5070be5 e6de5-22ac-44c3-a62f-1e08e5070be5 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Tipmont Rural Elec Member Corp Effective date: 2010/01/22 End date if known: Rate name: SCHEDULE SL: 175W Mercury Vapor Flood Overhead service(metered) Sector: Lighting Description: 1. AVAILABILITY Available for overhead street lighting in the towns of Battle Ground, Linden, New Richmond, Wingate, and Romney, in accordance with contracts which may be signed by each municipality or by the sponsoring organization. 2. CHARACTER OF SERVICE Tipmont Rural Electric Membership Corporation (REMC) will furnish all necessary equipment to operate and maintain an overhead street lighting system in conjunction with and as a part of its general overhead electric distribution system, and the REMC will furnish all electric power required for the purpose of furnishing overhead street lighting service to the member. The municipalities shall pay all installation, labor and material of additional poles and conductor required to extend existing lines to the proposed street light locations. The lighting hours for the said overhead street lighting system shall be on a "dusk to dawn" schedule, which provides that lamps are to be lighted approximately one-half hour after sunset until approximately one-half hour before sunrise each day in the year.

432

Evaluation of Emerging Line Inspection Technologies  

Science Conference Proceedings (OSTI)

This report describes field tests to examine various technologies available to establish conductor temperature during lidar field surveys of existing transmission lines. This is critical to assembling a proper line model to determine accurate sags and clearances. Lidar surveys are intended to demonstrate whether transmission lines have required clearances under full rating and specified environmental conditions. Typically, the technique used to establish conductor temperature at the ...

2012-11-28T23:59:59.000Z

433

Electrical Effects of HVDC Transmission Lines  

Science Conference Proceedings (OSTI)

High-voltage direct current (HVDC) transmission lines are used to transmit large amounts of power over long distances. The Electric Power Research Institute (EPRI) and others have produced many publications over approximately the past three decades, expounding on this topic. Several HVDC transmission lines have been built and have been in operation around the world over that period, and recently, there has been increased interest in the advantages that HVDC transmission affords. HVDC lines, like high-vol...

2010-12-23T23:59:59.000Z

434

Plains & Eastern Clean Line Project Proposal for New or Upgraded...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Plains & Eastern Clean Line Project Proposal for New or Upgraded Transmission Line Projects Under Section 1222 of the Energy Policy Act of 2005 Plains & Eastern Clean Line Project...

435

20120131 DOE Congestion Study Clean Line Comments 2012  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Line is an independent developer of four long-haul, high voltage direct current ("HVDC") transmission lines across the United States. Clean Line focuses exclusively on connecting...

436

Point-line spaces related to Jordan pairs.  

E-Print Network (OSTI)

??A point-line space is an abstract geometric object that consists of a set of points and a set of lines such that on each line… (more)

Huggenberger, Simon

2009-01-01T23:59:59.000Z

437

Fermilab | Take Five for Goal Zero | Gloves | Lined Leather Gloves  

NLE Websites -- All DOE Office Websites (Extended Search)

Lined Leather Gloves Lined Leather Gloves Description Color Finish Uses FNAL Stock Number Fleece lined for warmth Keystone Thumb Shirred Elastic Back Color coded cuff indicates...

438

NIST: Atomic Spectros. - Spectral Line Shapes, etc.  

Science Conference Proceedings (OSTI)

... For a Maxwellian velocity distribution, the line shape is Gaussian; the full width at ... Shapes are often approximately Lorentzian, ie, I(?) ? {1 + [(? - ? 0 ...

439

Transmission Line Security Monitor: Final Report  

SciTech Connect

The Electric Power Transmission Line Security Monitor System Operational Test is a project funded by the Technical Support Working Group (TSWG). TSWG operates under the Combating Terrorism Technical Support Office that functions under the Department of Defense. The Transmission Line Security Monitor System is based on technology developed by Idaho National Laboratory. The technology provides a means for real-time monitoring of physical threats and/or damage to electrical transmission line towers and conductors as well as providing operational parameters to transmission line operators to optimize transmission line operation. The end use is for monitoring long stretches of transmission lines that deliver electrical power from remote generating stations to cities and industry. These transmission lines are generally located in remote transmission line corridors where security infrastructure may not exist. Security and operational sensors in the sensor platform on the conductors take power from the transmission line and relay security and operational information to operations personnel hundreds of miles away without relying on existing infrastructure. Initiated on May 25, 2007, this project resulted in pre-production units tested in realistic operational environments during 2010. A technology licensee, Lindsey Manufacturing of Azusa California, is assisting in design, testing, and ultimately production. The platform was originally designed for a security monitoring mission, but it has been enhanced to include important operational features desired by electrical utilities.

John Svoboda

2011-04-01T23:59:59.000Z

440

Northern Pass Transmission Line Project Environmental Impact...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Northern Pass Transmission Line Project Environmental Impact Statement: Announcement of Change in Public Meeting Location: Federal Register Notice Volume 78, No. 181 - September...

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Emergency Management Lines of Inquiry, April 2008  

NLE Websites -- All DOE Office Websites (Extended Search)

3, 2008 EMERGENCY MANAGEMENT Inspection Criteria, Activities, and Lines of Inquiry Functional Area: Hazards Survey (HS) and Emergency Planning Hazards Assessment (EPHA) Inspection...

442

Gila to North Gila Transmission Line Rebuild  

NLE Websites -- All DOE Office Websites (Extended Search)

Western proposes to rebuild and upgrade two, parallel, 4.8-mile-long transmission lines located between Gila and North Gila Substations and take land actions...

443

Estes-Flatiron Transmission Line Rebuild  

NLE Websites -- All DOE Office Websites (Extended Search)

which is a cooperating agency in the project. The proposed project would: Rebuild aging and deteriorating transmission lines Reduce the number of linear miles of transmission...

444

Nonthermal effects on hydrogen-line profiles  

DOE Green Energy (OSTI)

Experimentally determined level populations of hydrogen excited states from a low-density Z pinch are used as initial conditions in a simulation to derive electron-velocity distributions. These velocity distributions show excess electrons in the high velocity end of the distribution when compared to a Maxwellian velocity distribution. The non-Maxwellian velocity distributions are used to find the nonequilibrium structure factors which are a main component in the plasma line broadening of hydrogen lines. The line profiles generated using the structure factors show plasmon satellites on the wings of the Balmer-..cap alpha..- and -..beta..-line profiles.

Lee, R.W.; Morgan, W.L.

1985-07-01T23:59:59.000Z

445

Line Heat-Source Guarded Hot Plate  

Science Conference Proceedings (OSTI)

Line Heat-Source Guarded Hot Plate. Description: The 1-meter guarded hot-plate apparatus measures thermal conductivity of building insulation. ...

2012-03-06T23:59:59.000Z

446

Emergency Management Lines of Inquiry, April 2008  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

23, 2008 EMERGENCY MANAGEMENT Inspection Criteria, Activities, and Lines of Inquiry Functional Area: Hazards Survey (HS) and Emergency Planning Hazards Assessment (EPHA) Inspection...

447

Effects of line shifts and the ion quadrupole contribution of spectral line asymmetries.  

SciTech Connect

Line asymmetries and the corresponding shift of spectral lines due to the electron penetration of the radiator orbitals and the ion quadrupole contribution become more significant with increasing principal quantum number and increasing electron density. The mean field static shift due to electron penetration of the orbitals gives rise to an overall shift of the line to lower energy and a significant asymmetry near line center, but does not generate much redhlue far wing asymmetry. The ion quadrupole contribution results in a small blue shift of the spectral line and a small change in asymmetry near line center, but it gives rise to a significant redhlue wing asymmetry in the far wings of the line. Experimental data fiom recent spherical implosion experiments on OMEGA shows evidence of the mean field static shift and may also show the effects of level interactions between the Ar Lyman -{gamma}, -{delta}, -{var_epsilon} lines and also the Ar He -{gamma}, -{delta} lines.

Gunderson, M. A. (Mark A.); Delamater, N. D. (Norman D.); Kilcrease, D. P. (David P.); Haynes, D. A. (Donald A.)

2002-01-01T23:59:59.000Z

448

Theoretical Atomic Physics code development IV: LINES, A code for computing atomic line spectra  

SciTech Connect

A new computer program, LINES, has been developed for simulating atomic line emission and absorption spectra using the accurate fine structure energy levels and transition strengths calculated by the (CATS) Cowan Atomic Structure code. Population distributions for the ion stages are obtained in LINES by using the Local Thermodynamic Equilibrium (LTE) model. LINES is also useful for displaying the pertinent atomic data generated by CATS. This report describes the use of LINES. Both CATS and LINES are part of the Theoretical Atomic PhysicS (TAPS) code development effort at Los Alamos. 11 refs., 9 figs., 1 tab.

Abdallah, J. Jr.; Clark, R.E.H.

1988-12-01T23:59:59.000Z

449

Neutrino Data from the Antarctic Muon and Neutrino Detector Array (AMANDA), the Predecessor of IceCube at the South Pole  

DOE Data Explorer (OSTI)

IceCube is a neutrino observatory for astrophysics with parts buried below the surface of the ice at the South Pole and an air-shower detector array exposed above. The international group of sponsors, led by the National Science Foundation (NSF), that designed and implemented the experiment intends for IceCube to operate and provide data for 20 years. Beginning in 2011, IceCube will record the interactions produced by astrophysical neutrinos with energies above 100 GeV, observing the Cherenkov radiation from charged particles produced in neutrino interactions. Its goal is to discover the sources of high-energy cosmic rays. These sources may be active galactic nuclei (AGNs) or massive, collapsed stars where black holes have formed.[Taken from http://www.icecube.wisc.edu/] The data currently available are from AMANDA, IceCube’s predecessor detector and experiment. AMANDA pioneered neutrino detection in ice. Over a period of years in the 1990s, detecting “strings” were buried and activated and by 2000, AMANDA was successfully recording an average of 1,000 neutrino events per year. IceCube will be a bigger and better version of AMANDA. Collected data have to be analyzed and processed, including a challenging process known as event reconstruction. The publicly available data are released after the main analyses are completed and results are published by the international AMANDA/IceCube Collaboration. The first set of data are from 2000 – 2006 and contain 6595 neutrino events.

Abbasi, R. et al

450

The Swinburne on-line education project  

Science Conference Proceedings (OSTI)

Many universities throughout the world are exploring the possibilities of on-line delivery of educational programs. These developments have the potential to significantly change the face of higher education as we know it today. In order to compete in ... Keywords: WWW, on-line education

C. J. Pilgrim; M. J. Creek

1998-08-01T23:59:59.000Z

451

results and benefits... The Bittern Line Carbon  

E-Print Network (OSTI)

results and benefits... The Bittern Line Carbon Neutral Stations Transport Regeneration Ltd. June 2008 c a s e s t u d yCRed carbon reduction Project Summary Our client, Transport Regeneration Ltd., aims to make nine stations on the Bittern Line between Norwich and Sheringham carbon neutral

Everest, Graham R

452

Requirements Uncertainty in a Software Product Line  

Science Conference Proceedings (OSTI)

A complex system's requirements almost always remain uncertain late into its software development. In gas turbine engine control systems at Rolls-Royce, for a traditional project (non-product line) typically 50% of requirements will change between Critical ... Keywords: Requirements, Uncertainty, Software Product Lines

Andy J. Nolan; Silvia Abrahao; Paul C. Clements; Andy Pickard

2011-08-01T23:59:59.000Z

453

Product Line Pricing in a Supply Chain  

Science Conference Proceedings (OSTI)

A vertically integrated channel would prefer to coordinate the pricing of its products. In this paper, we investigate drivers of product line pricing decisions in a bilateral monopoly where a manufacturer produces and sells two substitutable or complementary ... Keywords: complement, equilibrium, marketing, product line pricing, substitute, vertical strategic interaction

Lingxiu Dong; Chakravarthi Narasimhan; Kaijie Zhu

2009-10-01T23:59:59.000Z

454

Transmission line protection based on travelling waves  

Science Conference Proceedings (OSTI)

Major problem of tripping signal of a relay based on steady state component does not warranty faster tripping schemes for protection of extra high voltage transmission lines. Proposed work has made an attempt to find solution to the problem of fault ... Keywords: postfault voltage, relaying signals, surge impedence, transmission line protection, travelling waves

Anuradha S. Deshpande; Grishma S. Shah

2011-12-01T23:59:59.000Z

455

Base line estimation using sparse nonlinear operators  

Science Conference Proceedings (OSTI)

Efficient nonlinear operators for base line estimation of high energy physics detector signals are introduced. Due to the high processing rate requirements the operators are simplified using sparse input sequences. The operators are a sparse order statistic ... Keywords: base line estimation, filter training, order statistic filter

Sami J. Inkinen; Yrjö Neuvo

2002-05-01T23:59:59.000Z

456

Separation axioms and the fuzzy real lines  

Science Conference Proceedings (OSTI)

We show that for each lattice L which is completely distributive and equipped with an order-reversing involution, the canonical topology of the fuzzy real line @?(L) is uniformizable in the sense of Hutton; furthermore, this uniformity induces a pseudometric ... Keywords: ?-Hausdorff, Fuzzy subspace, Fuzzy topology, Product L-fuzzy real line, Pseudometrizable, Quasi-uniformity, Suitable, Uniformity

S. E. Rodabaugh

1983-01-01T23:59:59.000Z

457

Accelerating line extraction based on GPU  

Science Conference Proceedings (OSTI)

A new line extraction accelerating algorithm based upon graphics processing units (GPUs) is presented. Several techniques are proposed to optimize the GPU computation. Among those improvements, the most important one is the use of "seed pixels", which ... Keywords: GPU, line extraction, parallel processing, phase-based grouping

Li Yu; Xiao'an Tang; Bo Tang

2011-12-01T23:59:59.000Z

458

A Fast Line-by-Line Method for Atmospheric Absorption Computations: The Automatized Atmospheric Absorption Atlas  

Science Conference Proceedings (OSTI)

A computationally fast line-by-line method for the determination of atmospheric absorption is described. This method is based on the creation of an Automatized Atmospheric Absorption Atlas (4A) covering all possible plausible atmospheric ...

N. A. Scott; A. Chedin

1981-07-01T23:59:59.000Z

459

Interfacial Electrical Conductivity Enhancement of Aluminum ...  

Science Conference Proceedings (OSTI)

... are commonly used as conductor materials on overhead power transmission systems. ... temperature that endangers the reliability of power line components.

460

Actuation Methods for Enhanced Coverage  

E-Print Network (OSTI)

line explanation of the problem to be s olved • Full-featured robotic capabilities have high resource and energy overhead:

Aman Kansal; William Kaiser; Greg Pottie; Mani Srivastava

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Application Filling Requirements for Transmission Line and Substation...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Application Filling Requirements for Transmission Line and Substation Construction Projects (Wisconsin) Application Filling Requirements for Transmission Line and Substation...

462

Coupled Lines/Multiport Measurement/Orthogonal Calibration  

Science Conference Proceedings (OSTI)

... understanding of lossy multiconductor transmission lines and modal cross powers. These theoretical developments in coupled line theory have led ...

2012-05-25T23:59:59.000Z

463

Kangley - Echo Lake Transmission Line Project, Final Environmental...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Selleck Kangley North Bend Cedar Falls Existing Transmission Lines Proposed Transmission Line Alternatives Under Consideration BPA Substation Alternative * * * * * * ...

464

LineScout technology: from inspection to robotic maintenance on live transmission power lines  

Science Conference Proceedings (OSTI)

Power line inspection and maintenance practices are evolving as changing market regulations, significantly increased line loading and system availability requirements put pressure on grid owners to innovate. Robotics is thus making its debut in that ... Keywords: field robotics, mechanical design, power line inspection robot, telerobotics

Nicolas Pouliot; Serge Montambault

2009-05-01T23:59:59.000Z

465

UPDATE TO PLAINS & EASTERN CLEAN LINE PROPOSAL FOR NEW OR UPGRADED TRANSMISSION LINE PROJECTS  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

UPDATE TO PLAINS & EASTERN CLEAN LINE PROPOSAL UPDATE TO PLAINS & EASTERN CLEAN LINE PROPOSAL FOR NEW OR UPGRADED TRANSMISSION LINE PROJECTS UNDER SECTION 1222 OF THE ENERGY POLICY ACT OF 2005 AUGUST 2011 Table of Contents 1. Executive Summary .......................................................................................................... 1 2. Project Update .................................................................................................................. 2 a. Jobs and Economic Development ........................................................................................................... 5 b. Interconnection Studies ............................................................................................................................. 6 c. Routing and Public Outreach ................................................................................................................... 7

466

Continuous-wave quasi-phase-matched generation of 60thinspthinspmW at 465thinspthinspnm by single-pass frequency doubling of a laser diode in backswitch-poled lithium niobate  

Science Conference Proceedings (OSTI)

We report continuous-wave single-pass second-harmonic generation (SHG) in 4-{mu}m -period 0.5-mm-thick backswitch-poled lithium niobate. Pump sources at 920{endash}930thinspthinspnm include both Ti:sapphire and diode-oscillator{endash}amplifier lasers. SHG of a Ti:sapphire laser at 6.1{percent}/W efficiency, producing 61thinspthinspmW of power at 460thinspthinspnm, is demonstrated in 50-mm-long periodically poled lithium niobate samples with a nonlinear coefficient d{sub eff}{approx}9 pm/V , and 60thinspthinspmW at 465thinspthinspnm and 2.8{percent}/W efficiency is obtained by SHG of a laser-diode source. {copyright} {ital 1999} {ital Optical Society of America}

Batchko, R.G.; Fejer, M.M.; Byer, R.L. [Ginzton Laboratory, Stanford University, Stanford, California 94305-4085 (United States); Woll, D.; Wallenstein, R. [Fachbereich Physik, Universitaet Kaiserslautern, Erwin-Schroedinger-Strasse 46, D-67663 Kaiserslautern (Germany); Shur, V.Y. [Institute of Physics and Applied Mathematics, Ural State University, Ekaterinburg 620083 (Russia); Erman, L. [Coherent Laser Group, 5100 Patrick Henry Drive, Santa Clara, California 95054 (United States)

1999-09-01T23:59:59.000Z

467

Productivity Improvement of a Manual Assembly Line  

E-Print Network (OSTI)

The current project addresses the productivity improvement of a manual assembly line by making use of operations analysis in the framework of Lean production. A methodology is proposed that helps to improve the productivity of any production process. The methodology consists of selecting a product or product family to be studied followed by current process study. Once the existing process is documented, all the assembly tasks involved must be timed using time study techniques. Operations analysis enables the reduction of non-productive tasks and results in a set of standardized work elements along with the set of standard procedures for performing the operations. Assembly line balancing along with the associated operations analysis assists in constructing or re-configuring an assembly system, which is the key step in improving the overall performance of an assembly line. Following this approach, two manual assembly line configurations (single stage parallel line and five-stage serial line) are constructed for a case study. The results show that by changing over to the single stage assembly line configuration the operator productivity is doubled when compared to the existing assembly method.

Yerasi, Pranavi

2011-08-01T23:59:59.000Z

468

The effects of non-hydrostatic compression and applied electric field on the electromechanical behavior of poled PZT 95/5-2Nb ceramic during the F{sub R1} {yields} A{sub 0} polymorphic phase transformation  

SciTech Connect

We conducted hydrostatic and constant-stress-difference (CSD) experiments at room temperature on two different sintered batches of poled, niobium-doped lead-zirconate-titanate ceramic (PZT 95/5-2Nb). The objective of this test plan was to quantify the effects of nonhydrostatic stress on the electromechanical behavior of the ceramic during the ferroelectric, rhombohedral {yields} antiferroelectric, orthorhombic (FE {yields} AFE) phase transformation. We also performed a series of hydrostatic and triaxial compression experiments in which a 1000 V potential was applied to poled specimens to evaluate any effect of a sustained bias on the transformation. As we predicted from earlier tests on unpoled PZT 95/5-2Nb, increasing the stress difference up to 200 MPa (corresponding to a maximum resolved shear stress of 100 MPa) decreases the mean stress and confining pressure at which the transformation occurs by 25--33%, for both biased and unbiased conditions. This same stress difference also retards the rate of transformation at constant pressurization rate, resulting in reductions of up to an order of magnitude in the rate of charge release and peak voltage attained in our tests. This shear stress-voltage effect offers a plausible, though qualitative explanation for certain systematic failures that have occurred in neutron generator power supplies when seemingly minor design changes have been made. Transformation strains in poled ceramic are anisotropic (differing by up to 33%) in hydrostatic compression, and even more anisotropic under non-hydrostatic stress states. Application of a 1000 V bias appears to slightly increase (by {le}2%) the transformation pressure for poled ceramic, but evidence for this conclusion is weak.

Zeuch, D.H.; Montgomery, S.T.; Zimmerer, D.J.

1995-10-01T23:59:59.000Z

469

pi. pi. scattering by pole extrapolation methods. [2. 67 GeV/c, angular distribution, Chew-Low and Durr-Pilkum methods, OPE model, isospin  

SciTech Connect

A 25-inch hydrogen bubble chamber was used at the Lawrence Berkeley Laboratory Bevatron to produce 300,000 pictures of ..pi../sup +/p interactions at an incident momentum of the ..pi../sup +/ of 2.67 GeV/c. The 2-prong events were processed using the FSD and the FOG-CLOUDY-FAIR data reduction system. Events of the nature ..pi../sup +/p ..-->.. ..pi../sup +/p..pi../sup 0/ and ..pi../sup +/p ..-->.. ..pi../sup +/..pi../sup +/n with values of momentum transfer to the proton of -t less than or equal to 0.238 GeV/sup 2/ were selected. These events were used to extrapolate to the pion pole (t = m/sub ..pi..//sup 2/) in order to investigate the ..pi.. ..pi.. interaction with isospins of both T = 1 and T = 2. Two methods were used to do the extrapolation: the original Chew-Low method developed in 1959 and the Durr-Pilkuhn method developed in 1965 which takes into account centrifugal barrier penetration factors. At first it seemed that, while the Durr-Pilkuhn method gave better values for the total ..pi.. ..pi.. cross section, the Chew-Low method gave better values for the angular distribution. Further analysis, however, showed that if the requirement of total OPE (one-pion-exchange) were dropped, then the Durr-Pilkuhn method gave more reasonable values of the angular distribution as well as for the total ..pi.. ..pi.. cross section.

Lott, F.W. III

1977-12-09T23:59:59.000Z

470

Definition: Tie Line | Open Energy Information  

Open Energy Info (EERE)

Authority Area, smart grid References Glossary of Terms Used in Reliability Standards An in LikeLike UnlikeLike You like this.Sign Up to see what your friends like. line...

471

Definition: Tie Line Bias | Open Energy Information  

Open Energy Info (EERE)

Line Bias Line Bias Jump to: navigation, search Dictionary.png Tie Line Bias A mode of Automatic Generation Control that allows the Balancing Authority to maintain its Interchange Schedule and respond to Interconnection frequency error.[1] Related Terms Balancing Authority, Automatic Generation Control, frequency error, smart grid References ↑ Glossary of Terms Used in Reliability Standards An inl LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ine Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Tie_Line_Bias&oldid=502569" Categories: Definitions ISGAN Definitions What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load)

472

Insulate Steam Distribution and Condensate Return Lines  

Science Conference Proceedings (OSTI)

This revised ITP tip sheet on insulating steam distribution and condensate return lines provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

473

On the Generation of African Squall Lines  

Science Conference Proceedings (OSTI)

Squall lines (SLs) form an important component of the meteorology of northern Africa, and in particular, contribute substantially to rainfall totals. Their generation requires the existence of a potentially unstable low-level supply of moisture ...

David P. Rowell; James R. Milford

1993-06-01T23:59:59.000Z

474

Clean Lines: Strategies for Reducing Your Environmental ...  

Science Conference Proceedings (OSTI)

... Flow restrictors to prevent the flow in a water-supply pipe from exceeding a ... On manual lines, racks can be hung on bars over process baths to allow ...

2013-08-16T23:59:59.000Z

475

Momentum Transport by a Line of Cumulonimbus  

Science Conference Proceedings (OSTI)

The vertical transport of horizontal momentum normal to a line of cumulonimbus observed during GATE on 14 September 1974 is against the vertical momentum gradient, contrary to the predictions of mixing-length theory. Data from repeated aircraft ...

Margaret A. LeMone

1983-07-01T23:59:59.000Z

476

Mesoscale Structure of an Oklahoma Squall Line  

Science Conference Proceedings (OSTI)

A squall line, which passed through the National Severe Storms Laboratory measonetwork in Oklahoma on 26 April 1969, is analyzed to determine the mesoscale structure. The analyses are based on data from 23 rawinsonde ascents, 29 automatically ...

Judith Stokes Bradberry

1981-05-01T23:59:59.000Z

477

Corona losses in HVdc bipolar lines  

SciTech Connect

The problem related to the prediction of corona losses in HVdc bipolar lines has been solved, in the past, by means of semi-empirical monomial formulae. However, the proposed formulae that are simpler to use do not always give adequate calculation precision, while the formulae that provide the closest results require implicit functions of different complexity, which are difficult to apply; moreover, it is not possible to understand clearly what influence the variations of the different line parameters have on the losses themselves. The new monomial semi-empirical relationship, proposed to predict the corona losses in HVdc bipolar lines, is very simple to use; it highlights the dependence of power losses due to the corona effect by the different line parameters. The formula has been developed by elaborating a considerable amount of available experimental data.

Corbellini, U.; Pelacchi, P. [Univ. of Pisa (Italy). Dept. of Electric Systems and Automation

1996-07-01T23:59:59.000Z

478

Electrical Transmission Line Diametrical Retention Mechanism  

DOE Patents (OSTI)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT); Fox, Joe (Spanish Fork, UT)

2006-01-03T23:59:59.000Z

479

Electrical Characterization of Textile Transmission Lines  

E-Print Network (OSTI)

In this paper, electrical characterization and modeling of conductive textiles are presented. A dedicated measurement setup has been developed to allow reliable connection of the textile samples with the equipment cables. Geometrical fabric structures and fabrication tolerances as well as high frequency properties up to 6 GHz for four types of textiles have been determined. Transmission lines with controlled characteristic impedance have been realized enabling the characterization of typical line attenuation factors. This work shows that textile transmission lines can be used for frequencies up to 1.2 GHz and 120 MHz with the maximal lengths of 10 and 100 cm, respectively. Index Terms---Attenuation constants, characteristic impedance, conductive textiles, transmission lines, wearable computing.

Didier Cottet; Janusz Grzyb; Student Member; Student Member; Tünde Kirstein; Gerhard Tröster; Senior Member

2003-01-01T23:59:59.000Z

480

On-line Condenser Fouling Monitor Development  

Science Conference Proceedings (OSTI)

This newly developed, innovative, on-line fouling monitor can continuously display the cleanliness factor of an operating condenser. The monitor facilitates optimization of cooling water treatment and condenser cleaning schedules.

1998-03-17T23:59:59.000Z

Note: This page contains sample records for the topic "overhead lines poles" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Claw-free graphs and line graphs.  

E-Print Network (OSTI)

??The research of my dissertation is motivated by the conjecture ofThomassen that every 4-connected line graph is hamiltonian and by the conjecture ofTutte that every… (more)

Shao, Yehong, 1976-

2005-01-01T23:59:59.000Z

482

Power line communications for smart grid applications  

Science Conference Proceedings (OSTI)

Power line communication, that is, using the electricity infrastructure for data transmission, is experiencing a renaissance in the context of Smart Grid. Smart Grid objectives include the integration of intermittent renewable energy sources into the ...

Lars Torsten Berger, Andreas Schwager, J. Joaquín Escudero-Garzás

2013-01-01T23:59:59.000Z

483

Design of the ILC RTML Extraction Lines  

SciTech Connect

The ILC [1] Damping Ring to the Main Linac beamline (RTML) contains three extraction lines (EL). Each EL can be used both for an emergency abort dumping of the beam and tune-up continual train-by-train extraction. Two of the extraction lines are located downstream of the first and second stages of the RTML bunch compressor, and must accept both compressed and uncompressed beam with energy spreads of 2.5% and 0.15%, respectively. In this paper we report on an optics design that allowed minimizing the length of the extraction lines while offsetting the beam dumps from the main line by the distance required for acceptable radiation levels in the service tunnel. The proposed extraction lines can accommodate beams with different energy spreads while at the same time providing the beam size acceptable for the aluminum dump window. The RTML incorporates three extraction lines, which can be used for either an emergency beam abort or for a train-by-train extraction. The first EL is located downstream of the Damping Ring extraction arc. The other two extraction lines are located downstream of each stage of the two-stage bunch compressor. The first extraction line (EL1) receives 5GeV beam with an 0.15% energy spread. The extraction line located downstream of the first stage of bunch compressor (ELBC1) receives both compressed and uncompressed beam, and therefore must accept beam with both 5 and 4.88GeV energy, and 0.15% and 2.5% energy spread, respectively. The extraction line located after the second stage of the bunch compressor (ELBC2) receives 15GeV beam with either 0.15 or 1.8% energy spread. Each of the three extraction lines is equipped with the 220kW aluminum ball dump, which corresponds to the power of the continuously dumped beam with 5GeV energy, i.e., the beam trains must be delivered to the ELBC2 dump at reduced repetition rate.

Seletskiy, S.; Tenenbaum, P.; Walz, D.; /SLAC; Solyak, N.; /Fermilab

2011-10-17T23:59:59.000Z

484

Electrical Effects of HVDC Transmission Lines--2012  

Science Conference Proceedings (OSTI)

Electrical effects may constrain the design of prospective high-voltage direct current (HVDC) lines, when either alone or sharing the same structures with high-voltage alternating current (HVAC) lines. In 2012, the Electric Power Research Institute (EPRI) research focused on electric field and ion density at ground level. The ultimate goal is to calculate with confidence these electrical effects. The work built on research previously performed, including pioneering research performed at EPRI’s ...

2012-12-12T23:59:59.000Z

485

500-kV Transmission Line Design  

Science Conference Proceedings (OSTI)

The design of an extrahigh-voltage (EHV) transmission line involves an integrated analysis and comparison of influencing factors to develop a structure configuration and conductor/shieldwire system that will provide safe, reliable, and economic service. Many of the parameters in design have varied impacts on the performance characteristics of a transmission line: safety, reliability, capital cost, and lifetime cost. The interdependencies are many and technical in nature. Having a solid knowledge of the p...

2011-02-04T23:59:59.000Z

486

Perspective: Power Lines and Motor Vehicle Electronics  

Science Conference Proceedings (OSTI)

Recent news reports have suggested that the operation of automotive electronic systems (including sudden acceleration) could be affected by the electric and magnetic fields associated with power transmission lines. Based on electromagnetic fundamentals and knowledge of the levels of electric fields, magnetic fields and RF fields from transmission lines, one can evaluate the possibility of an interaction between these exposures and the electronic systems within automobiles, both electric and conventional.

2010-06-06T23:59:59.000Z

487

Electrical Effects of HVDC Transmission Lines  

Science Conference Proceedings (OSTI)

Electrical effects can constrain the design of prospective high-voltage direct current (HVDC) lines operating either alone or sharing the same rights of way structures with high-voltage alternate current (HVAC) lines. In 2013, the Electric Power Research Institute (EPRI) research on HVDC electrical effects focused on electric field and ion density at ground level. The ultimate goal of the project is to calculate with confidence these electrical effects. The algorithms on which the software currently ...

2013-11-08T23:59:59.000Z

488

Central Georgia El Member Corp | Open Energy Information  

Open Energy Info (EERE)

Georgia El Member Corp Georgia El Member Corp Place Georgia Utility Id 3248 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Outdoor Lighting Overhead Wiring HPS 100 W Existing Pole Lighting Outdoor Lighting Overhead Wiring HPS 100 W No Exisitng Pole Lighting Outdoor Lighting Overhead Wiring HPS 250 W Existing Pole Lighting Outdoor Lighting Overhead Wiring HPS 250 W No Existing Pole Lighting Outdoor Lighting Underground Wiring 100 W Lighting Outdoor Lighting Underground Wiring 250 W Lighting

489

Dissolution of FB-Line Cabinet Sweepings  

DOE Green Energy (OSTI)

Three FB-Line samples were received by the Savannah River National Laboratory (SRNL) for characterization and evaluation for suitability for HB-Line dissolution. These samples are part of a larger sampling/evaluation program in support of FB-Line deinventory efforts. The samples studied were identified as MC04-147- HBL, MC04-148-HBL, and FBL-SWP-04-016-HBL (N). The first sample, MC04-147-HBL, is a portion of FB-Line Packaging and Stabilization (P&S) materials. The second sample, MC04-148-HBL, is a sweeping from Cabinet 6-8, which is not representative of the mechanical line. The third sample, FBL-SWP-04-016-HBL (N), is an FB-Line North cabinet sweeping. The samples were described by FB-Line personnel as containing plutonium oxide (PuO{sub 2}) which had not been high-fired. This description was generally confirmed by solids analysis and off gas measurements. All three samples were dissolved in 8 M HNO{sub 3}/0.1 M KF at 90-100 C leaving minor amounts of solid residue. During dissolution, sample MC04-147 did not generate hydrogen gas. Sample MC04-148 generated modest amounts of gas, which contained 4.0 to 4.7 volume percent (vol %) hydrogen (H{sub 2}) at a ratio of up to 8.4 x 10{sup -5} mol H{sub 2}/g sample. Sample FBL-SWP-04-016-HBL (N) was nearly completely soluble in 8 M HNO{sub 3}and produced a very small amount of gas. Apparently, the CaF{sub 2} in that sample dissolves and provides sufficient fluoride to support the dissolution of other components.

Crowder, Mark L.

2005-06-14T23:59:59.000Z

490

Relationship between System Slope and Updraft Intensity in Squall Lines  

Science Conference Proceedings (OSTI)

In recent years there has been debate about whether squall lines have an “optimal state.” It has been repeatedly demonstrated that the slope of a squall line’s convective region is related to the comparative magnitudes of the squall line’s cold ...

Matthew D. Parker

2010-09-01T23:59:59.000Z

491

Modeling and analysis of electrical power lines for broadband power line communications.  

E-Print Network (OSTI)

??This research seeks to expand the knowledge in the characteristics of power lines and to develop a channel model that can be used for designing… (more)

Meng, Han.

2008-01-01T23:59:59.000Z

492

Double Bottom Line Project Report:Assessing Social Impact In Double Bottom Line Ventures  

E-Print Network (OSTI)

of Key Characteristics Glossary Method Summaries Theories ofin double bottom line ventures methods catalog glossary ofterms glossary of terms This glossary defines the variables

Rosenzweig, William

2004-01-01T23:59:59.000Z

493

MCP Upgrade: Transmission Line and Pore Importance  

E-Print Network (OSTI)

In order to take advantage of all of the benefits of Multi-Channel Plate Photo-Multiplier Tubes (MCPs) a fast and efficient readout scheme must be implemented. One scheme that appears very promising is that of a transmission line coupled to a digital sampling readout. Transmission line readout allows for 2D position reconstruction, as well as an extremely fast response time, allowing for an exceptional timing resolution. I will be discussing the development of a method to connect the transmission line readout to the anode of the MCP, as well as testing the resultant MCP-transmission line readout system. This testing occurred at Argonnes laser lab, which featured a tunable fast rise time laser as well as a data acquisition system with a low noise level. A study to determine the importance of the pore size of the MCP was also carried out at Argonnes laser lab. In this study two MCPs which differed only in pore size (25µm and 10µm) were tested and their timing resolutions were compared. The objective of the following discussion is to quantify the effectiveness of the transmission line readout, learn more about the nature of the MCP and its signals, and look for ways in which to improve upon the present readout technique. 2 Tyler Natoli 1

Tyler Natoli; Advisor Henry Frisch

2009-01-01T23:59:59.000Z

494

A high accuracy computed water line list  

E-Print Network (OSTI)

A computed list of H$_{2}$$^{16}$O infra-red transition frequencies and intensities is presented. The list, BT2, was produced using a discrete variable representation two-step approach for solving the rotation-vibration nuclear motions. It is the most complete water line list in existence, comprising over 500 million transitions (65% more than any other list) and it is also the most accurate (over 90% of all known experimental energy levels are within 0.3 cm$^{-1}$ of the BT2 values). Its accuracy has been confirmed by extensive testing against astronomical and laboratory data. The line list has been used to identify individual water lines in a variety of objects including: comets, sunspots, a brown dwarf and the nova-like object V838 Mon. Comparison of the observed intensities with those generated by BT2 enables physical values to be derived for these objects. The line list can also be used to provide an opacity for models of the atmospheres of M-dwarf stars and assign previously unknown water lines in laboratory spectra.

R. J. Barber; J. Tennyson; G. J. Harris; R. N. Tolchenov

2006-01-11T23:59:59.000Z

495

Visual Aspects of the Flanking Line in Severe Thunderstorms  

Science Conference Proceedings (OSTI)

Photographs are presented that illustrate the various forms in which “flanking lines” exist in nature. Flanking lines may appear not only as the commonly observed sloping line of cumulus congestus, but also as erect towers with a vertical face, ...

Howard B. Bluestein

1986-04-01T23:59:59.000Z

496