Powered by Deep Web Technologies
Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Outdoor Lighting Resources  

Energy.gov (U.S. Department of Energy (DOE))

DOE offers a variety of resources to guide municipalities, utilities, and others in their evaluation of LED street lighting products.

2

High Performance Outdoor Lighting Accelerator  

Energy.gov (U.S. Department of Energy (DOE))

Hosted by the U.S. Department of Energy (DOE)’s Weatherization and Intergovernmental Programs Office (WIPO), this webinar covered the expansion of the Better Buildings platform to include the newest initiative for the public sector: the High Performance Outdoor Lighting Accelerator (HPOLA).

3

Pedestrian Friendly Outdoor Lighting  

SciTech Connect

This GATEWAY report discusses the problems of pedestrian lighting that occur with all technologies with a focus on the unique optical options and opportunities offered by LEDs through the findings from two pedestrian-focused projects, one at Stanford University in California, and one at the Chautauqua Institution in upstate New York. Incorporating user feedback this report reviews the tradeoffs that must be weighed among visual comfort, color, visibility, efficacy and other factors to stimulate discussion among specifiers, users, energy specialists, and in industry in hopes that new approaches, metrics, and standards can be developed to support pedestrian-focused communities, while reducing energy use.

Miller, Naomi J.; Koltai, Rita; McGowan, Terry

2013-12-31T23:59:59.000Z

4

Outdoor Solar Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Outdoor Solar Lighting Outdoor Solar Lighting Outdoor Solar Lighting July 29, 2012 - 6:34pm Addthis Outdoor solar lights use solar cells, which convert sunlight into electricity, and are easy to install and virtually maintenance free. | Photo courtesy of ©iStockphoto.com/ndejan Outdoor solar lights use solar cells, which convert sunlight into electricity, and are easy to install and virtually maintenance free. | Photo courtesy of ©iStockphoto.com/ndejan What does this mean for me? Outdoor solar lights are easy to install and virtually maintenance free They work in most areas of the United States Find out if replacement bulbs or batteries are available before you buy them Outdoor solar lights are easy to install and virtually maintenance free. Best of all, using them won't increase your electric bill. Popular home

5

Outdoor Solar Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Outdoor Solar Lighting Outdoor Solar Lighting Outdoor Solar Lighting July 29, 2012 - 6:34pm Addthis Outdoor solar lights use solar cells, which convert sunlight into electricity, and are easy to install and virtually maintenance free. | Photo courtesy of ©iStockphoto.com/ndejan Outdoor solar lights use solar cells, which convert sunlight into electricity, and are easy to install and virtually maintenance free. | Photo courtesy of ©iStockphoto.com/ndejan What does this mean for me? Outdoor solar lights are easy to install and virtually maintenance free They work in most areas of the United States Find out if replacement bulbs or batteries are available before you buy them Outdoor solar lights are easy to install and virtually maintenance free. Best of all, using them won't increase your electric bill. Popular home

6

Outdoor Solid-State Lighting Technology Deployment | Department...  

Energy Savers (EERE)

Parking Lot Lighting FEMP Acquisition Guidance for Lighting Products (Powered by LED Lighting Facts) FEMP Outdoor Solid-State Lighting Initiative: Resources for Outdoor SSL...

7

TAP Webinar: High Performance Outdoor Lighting Accelerator  

Energy.gov (U.S. Department of Energy (DOE))

Hosted by the Technical Assistance Program (TAP), this webinar will cover the recently announced expansion of the Better Buildings platform —the High Performance Outdoor Lighting Accelerator (HPOLA).

8

Big Savings on Outdoor Lighting | Department of Energy  

Energy Savers (EERE)

take the time to upgrade outdoor lighting to save even more energy and money. Outdoor solar lighting is an energy saving and aesthetically pleasing way to light around your...

9

Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting Webcast  

Energy.gov (U.S. Department of Energy (DOE))

In this October 8, 2009 webcast, ENERGY STAR Program Manager Richard Karney gave an overview of ENERGY STAR criteria covering SSL-based outdoor area and roadway lighting, outdoor wall packs,...

10

Outdoor Solid-State Lighting Technology Deployment | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technologies » Technology Deployment » Outdoor Solid-State Technologies » Technology Deployment » Outdoor Solid-State Lighting Technology Deployment Outdoor Solid-State Lighting Technology Deployment October 7, 2013 - 9:10am Addthis Outdoor solid-state lighting (SSL) technology has the potential to reduce U.S. lighting energy usage by nearly one half and contribute significantly to our nation's climate change solutions. The U.S. Department of Energy's (DOE) Buildings Technologies Office offers a wealth of information on its Solid-State Lighting website. Visit the site to find: SSL Basics Studies and Reports CALiPER Summary Reports Tools SSL Webcasts. Also see: FEMP Outdoor SSL Initiative: Resources for Outdoor SSL Applications outlines resources available for outdoor solid-state lighting projects. Better Buildings Alliance: This DOE initiative is driven and managed

11

Summer Loving-Energy-Efficient Outdoor Lighting! | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Summer Loving-Energy-Efficient Outdoor Lighting! Summer Loving-Energy-Efficient Outdoor Lighting! Summer Loving-Energy-Efficient Outdoor Lighting! June 20, 2013 - 9:47am Addthis Outdoor solar lights use solar cells, which convert sunlight into electricity, and are easy to install and virtually maintenance free. | Photo courtesy of ©iStockphoto.com/ndejan Outdoor solar lights use solar cells, which convert sunlight into electricity, and are easy to install and virtually maintenance free. | Photo courtesy of ©iStockphoto.com/ndejan Erin Connealy Communications Specialist, Office of Energy Efficiency and Renewable Energy How can I participate? Check to see if energy-efficient or solar lighting can fit your outdoor lighting needs this summer. One of the best things about summer to me is all the time I get to spend

12

Model Specification for Networked Outdoor Lighting Control Systems  

Energy.gov (U.S. Department of Energy (DOE))

The DOE Municipal Solid-State Street Lighting Consortium's Model Specification for Networked Outdoor Lighting Control Systems is a tool designed to help cities, utilities, and other local agencies...

13

19CHALLENGE Summer 2006 OUTDOOR LIGHTING, INSECTS & BIRDS  

E-Print Network (OSTI)

-whocomplainofthevisualintrusion causedbysecuritylightsandinsensitivestreetlighting. It is common knowledge that street and security lights attract insects: indeed, 2000-watt light that the increasing numbers of urban street and security lights must have a measurable impact on the environment19CHALLENGE Summer 2006 OUTDOOR LIGHTING, INSECTS & BIRDS Is light pollution killing our birds

14

Solid-State Lighting: Hitting the Target: ENERGY STAR® SSL Outdoor Area  

NLE Websites -- All DOE Office Websites (Extended Search)

Hitting the Target: ENERGY Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting Webcast to someone by E-mail Share Solid-State Lighting: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting Webcast on Facebook Tweet about Solid-State Lighting: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting Webcast on Twitter Bookmark Solid-State Lighting: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting Webcast on Google Bookmark Solid-State Lighting: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting Webcast on Delicious Rank Solid-State Lighting: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting Webcast on Digg Find More places to share Solid-State Lighting: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting Webcast on AddThis.com...

15

Text-Alternative Version: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting  

Energy.gov (U.S. Department of Energy (DOE))

Below is the text-alternative version of the Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting Webcast.

16

Energy Department Announces Outdoor Winners of Next Generation Luminaires™ Solid-State Lighting Design Competition  

Office of Energy Efficiency and Renewable Energy (EERE)

The 2013 Next Generation LuminairesTM (NGL) Design Competition outdoor lighting category winners were announced Wednesday night at the Strategies in Light conference in Santa Clara, California. The...

17

The Municipal Solid-State Street Lighting Consortium Public Outdoor Lighting Inventory: Phase I: Survey Results  

SciTech Connect

This document presents the results of a voluntary web-based inventory survey of public street and area lighting across the U.S. undertaken during the latter half of 2013.This survey attempts to access information about the national inventory in a “bottoms-up” manner, going directly to owners and operators. Adding to previous “top down” estimates, it is intended to improve understanding of the role of public outdoor lighting in national energy use.

Kinzey, Bruce R.; Smalley, Edward; Haefer, R.

2014-09-30T23:59:59.000Z

18

A system with a tracking concentrating heliostat for lighting underground spaces with beams of sunlight  

Science Journals Connector (OSTI)

The results of the introduction of a solar-power installation for lighting and creating light effects in an underground room using mirror-concentrating systems are described.

Zh. Z. Akhadov; A. A. Abdurakhmanov; Yu. B. Sobirov; Sh. R. Kholov…

2014-04-01T23:59:59.000Z

19

FEMP Outdoor Solid-State Lighting Intiative: Resources for Outdoor SSL Applications  

Energy.gov (U.S. Department of Energy (DOE))

Fact sheet describes the Federal Energy Management Program's (FEMP) solid-state lighting (SSL) initiatives that provide information and resources for the application of SSL lighting in exterior spaces.

20

Light weight underground pipe or cable installing device  

SciTech Connect

This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.

Schosek, W. O.

1985-01-08T23:59:59.000Z

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

FEMP Outdoor Solid State Lighting Intiative: Resources for Outdoor SSL Applications  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Municipal Solid-State Street Lighting Municipal Solid-State Street Lighting Consortium Fact Sheet - The Consortium shares technical information and experi- ences related to LED street and area light- ing demonstrations. The Consortium also serves as an objective resource for evalu- ating new products on the market intended for street and area lighting applications. http://apps1.eere.energy.gov/buildings/ publications/pdfs/ssl/consortium_fs.pdf DOE SSL GATEWAY Demonstration Project Results - DOE GATEWAY dem- onstrations showcase high-performance LED products for general illumination in a variety of commercial and residential applications. Demonstration results pro- vide real-world experience and data on state-of-the-art SSL product performance and cost effectiveness. DOE CALiPER Test Results - The DOE

22

Permit Parking Emergency Blue Light  

E-Print Network (OSTI)

P P P P P P P P P P P P P P P P P PP P P P P P Permit Parking Food P P Emergency Blue Light underground Emergency Blue Light outdoors Wheelchair Wheelchair prior arrangements necessary Telephone Visitor 144 Albert Street 21 152 Albert Street 20 154 Albert Street 94 34 Barrie Street 91 68 Barrie Street 90

Abolmaesumi, Purang

23

Online Tracking of Outdoor Lighting Variations for Augmented Reality with Moving Cameras  

E-Print Network (OSTI)

and Xavier Granier Fig. 1. Resulting integration of a virtual teapot into the building video sequence with moving viewpoints. The virtual teapot is lighted using a illumination model composed of sunlight to frame between the real scene and the teapot. Abstract--In augmented reality, one of key tasks to achieve

Paris-Sud XI, Université de

24

Outdoor Manners  

NLE Websites -- All DOE Office Websites (Extended Search)

Outdoor Manners Outdoor Manners Nature Bulletin No. 683-A June 10, 1978 Forest Preserve District of Cook County George W. Dunne, President Roland F. Eisenbeis, Supt. of Conservation OUTDOOR MANNERS I AM AN OLD TIME COUNTRY LANE -- just a plain dirt road with a lot of ups and downs, built by the pioneers who settled this region. I was abandoned, thank goodness, after those tin Lizzies began to honk and rattle through the country. They didn't like me and I didn't like them. For more than a century, people went this way on foot, on horseback, and in vehicles drawn by horses or mules. I became well acquainted with many of them and some of their great-grandchildren. They became acquainted with my trees, my wildflowers, the birds and all of my wild creatures. In those days most folks were friendly, neighborly people. They had time to stop, visit, look and listen.

25

Outdoor Cooking.  

E-Print Network (OSTI)

................................ ALUMINUM FOIL COOKERY 11 ..................................... OTHER OUTDOOR FOODS 12 Appetizers ................................................................. 1: Breads ....................................................................... 13... for coals ialt md pepw ,s&kers and special seasonings 1 board : slicing knives i sprinkler wndled skillets and saucman MAKING THE FIRE Line the bottom of the fire box with heavy duty aluminum foil. Then make a fire base of gravel or similar...

Douglas, Jenoyce; Reasonover, Frances

1967-01-01T23:59:59.000Z

26

Next Generation Luminaires Design Competition Announces 2013 Outdoor Winners  

Energy.gov (U.S. Department of Energy (DOE))

The 2013 winners in the outdoor category of the Next Generation Luminaires Solid-State Lighting Design Competition were announced at the Strategies in Light conference in Santa Clara, CA.

27

Lighting Test Facilities  

NLE Websites -- All DOE Office Websites (Extended Search)

Custom Projects Lighting Test Facilities SSL Guidelines Industrial Federal Agriculture LED Street and Area Lighting Field Test of Exterior LED Down Lights Abstract Outdoor...

28

Underground Exploration  

E-Print Network (OSTI)

Underground Exploration and Testing A Report to Congress and the Secretary of Energy Nuclear Waste Technical Review Board October 1993 Yucca Mountain at #12;Nuclear Waste Technical Review Board Dr. John E and Testing #12;Executive Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Introduction

29

Covered Product Category: Exterior Lighting | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Workbook: A how-to guide for outdoor lighting developed by the National Park Service and DOE. Outdoor Solid State Lighting Technology Deployment: FEMP encourages Federal agencies...

30

Outdoor Recreation welcomes new director  

E-Print Network (OSTI)

Outdoor Recreation welcomes new director Outdoor Recreation welcomed the program's new director Liz, Outdoor Recreation hosted its 5th annual Carolina Crush Climbing Competition at the Strom Thurmond with the Make-A-Wish Foundation, Outdoor Recreation collaborated with the Make-A- Wish Club at USC to fundraise

Almor, Amit

31

Survey of tar sand deposits, heavy oil fields, and shallow light oil fields of the United States for underground coal gasification applications  

SciTech Connect

A literature survey was conducted to identify areas of the United States where tar sand deposits, heavy oil fields, or shallow light oil fields might be suitably associated with coal deposits for production of oil by in situ thermal recovery methods using heat derived from underground coal gasification (UCG) processes. The survey is part of a Department of Energy-sponsored program to develop new applications for UCG technology in utilizing coal resources that are unattractive for mining. Results from the survey indicate tar sand deposits, heavy oil fields, or light oil fields are probably or possibly located within 5 miles of suitable coal in 17 states (Table 1). Especially promising areas are in the Uinta Basin of Utah; the North Slope of Alaska; the San Miguel deposit in southwest Texas; the Illinois-Eastern Interior Basin area of western Kentucky, southwestern Indiana and Illinois; the tri-state area of Missouri, Kansas and Oklahoma; and the northern Appalachian Basin in eastern Ohio and northwestern Pennsylvania. The deposits in these areas warrant further evaluation. 30 refs., 4 figs., 1 tab.

Trudell, L.G.

1986-06-01T23:59:59.000Z

32

Outdoor PV Degradation Comparison  

SciTech Connect

As photovoltaic (PV) penetration of the power grid increases, it becomes vital to know how decreased power output; may affect cost over time. In order to predict power delivery, the decline or degradation rates must be determined; accurately. At the Performance and Energy Rating Testbed (PERT) at the Outdoor Test Facility (OTF) at the; National Renewable Energy Laboratory (NREL) more than 40 modules from more than 10 different manufacturers; were compared for their long-term outdoor stability. Because it can accommodate a large variety of modules in a; limited footprint the PERT system is ideally suited to compare modules side-by-side under the same conditions.

Jordan, D. C.; Smith, R. M.; Osterwald, C. R.; Gelak, E.; Kurtz, S. R.

2011-02-01T23:59:59.000Z

33

Use of the Modified Light Duty Utility Arm to Perform Nuclear Waste Cleanup of Underground Waste Storage Tanks at Oak Ridge National Laboratory  

SciTech Connect

The Modified Light Duty Utility Arm (MLDUA) is a selectable seven or eight degree-of-freedom robot arm with a 16.5 ft (5.03 m) reach and a payload capacity of 200 lb. (90.72 kg). The utility arm is controlled in either joystick-based telerobotic mode or auto sequence robotics mode. The MLDUA deployment system deploys the utility arm vertically into underground radioactive waste storage tanks located at Oak Ridge National Laboratory. These tanks are constructed of gunite material and consist of two 25 ft (7.62 m) diameter tanks in the North Tank Farm and six 50 ft (15.24 m) diameter tanks in the South Tank Farm. After deployment inside a tank, the utility arm reaches and grasps the confined sluicing end effecter (CSEE) which is attached to the hose management arm (HMA). The utility arm positions the CSEE within the tank to allow the HMA to sluice the tank's liquid and solid waste from the tank. The MLDUA is used to deploy the characterization end effecter (CEE) and gunite scarifying end effecter (GSEE) into the tank. The CEE is used to survey the tank wall's radiation levels and the physical condition of the walls. The GSEE is used to scarify the tank walls with high-pressure water to remove the wall scale buildup and a thin layer of gunite which reduces the radioactive contamination that is embedded into the gunite walls. The MLDUA is also used to support waste sampling and wall core-sampling operations. Other tools that have been developed for use by the MLDUA include a pipe-plugging end effecter, pipe-cutting end effecter, and pipe-cleaning end effecter. Washington University developed advance robotics path control algorithms for use in the tanks. The MLDUA was first deployed in June 1997 and has operated continuously since then. Operational experience in the first four tanks remediated is presented in this paper.

Blank, J.A.; Burks, B.L.; DePew, R.E.; Falter, D.D.; Glassell, R.L.; Glover, W.H.; Killough, S.M.; Lloyd, P.D.; Love, L.J.; Randolph, J.D.; Van Hoesen, S.D.; Vesco, D.P.

1999-04-01T23:59:59.000Z

34

Comparing Accelerated Testing and Outdoor Exposure | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Comparing Accelerated Testing and Outdoor Exposure Comparing Accelerated Testing and Outdoor Exposure Presented at the PV Module Reliability Workshop, February 26 - 27 2013,...

35

Underground Layout Configuration  

SciTech Connect

The purpose of this analysis was to develop an underground layout to support the license application (LA) design effort. In addition, the analysis will be used as the technical basis for the underground layout general arrangement drawings.

A. Linden

2003-09-25T23:59:59.000Z

36

CALIFORNIA ENERGY California Outdoor Lighting Baseline  

E-Print Network (OSTI)

design, construction, and operation of building systems. The Integrated Energy Systems: Productivity Design of Commercial Building Ceiling Systems Integrated Design of Residential Ducting & Air Flow Systems of a larger research effort called Integrated Energy Systems: Productivity and Building Science Program

37

CALIFORNIA ENERGY Outdoor Lighting Survey Reports  

E-Print Network (OSTI)

efficiency is improved through the integrated design, construction, and operation of building systems of Small Commercial HVAC Systems Integrated Design of Commercial Building Ceiling Systems Integrated Design. The Integrated Energy Systems: Productivity and Building Science Program research addressed six areas

38

Science @WIPP: Underground Laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

WIPP WIPP Underground Laboratory Double Beta Decay Dark Matter Biology Repository Science Renewable Energy Underground Laboratory The deep geologic repository at WIPP provides an ideal environment for experiments in many scientific disciplines, including particle astrophysics, waste repository science, mining technology, low radiation dose physics, fissile materials accountability and transparency, and deep geophysics. The designation of the Carlsbad Department of Energy office as a "field" office has allowed WIPP to offer its mine operations infrastructure and space in the underground to researchers requiring a deep underground setting with dry conditions and very low levels of naturally occurring radioactive materials. Please contact Roger Nelson, chief scientist of the Department of

39

Underground Injection Control (Louisiana)  

Energy.gov (U.S. Department of Energy (DOE))

The Injection and Mining Division (IMD) has the responsibility of implementing two major federal environmental programs which were statutorily charged to the Office of Conservation: the Underground...

40

Pedestrian-Friendly Nighttime Lighting  

Energy.gov (U.S. Department of Energy (DOE))

This November 19, 2013 webinar presented issues and considerations related to pedestrian-friendly nighttime lighting, such as color rendering, safety, and adaptation. When it comes to outdoor...

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Lighting Design | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Design Design Lighting Design July 29, 2012 - 6:28pm Addthis Energy-efficient indoor and outdoor lighting design focuses on ways to improve both the quality and efficiency of lighting. | Photo courtesy of ©iStockphoto.com/chandlerphoto. Energy-efficient indoor and outdoor lighting design focuses on ways to improve both the quality and efficiency of lighting. | Photo courtesy of ©iStockphoto.com/chandlerphoto. How does it work? Buy ENERGY STAR-rated lighting for the highest quality, energy-efficient lighting. Use timers and other controls to turn lights on and off. Use outdoor solar lighting. Energy-efficient indoor and outdoor lighting design focuses on ways to improve both the quality and efficiency of lighting. If you're constructing a new house, consider lighting as part of your whole-house design -- an

42

Underground Power Cables  

Science Journals Connector (OSTI)

...1973 research-article Underground Power Cables J. D. Endacott Up to the present, effectively...particular, in recent years, the oil-filled cable system using cellulose paper impregnated...design of supertension underground power cable systems are considered. The limitations...

1973-01-01T23:59:59.000Z

43

Usability of Outdoor Spaces in Children's Hospitals  

E-Print Network (OSTI)

Researchers have studied the positive effect of healing outdoor environments on hospitalized children, their family members and staff's health and mood. Consequently many modern hospitals dedicate portions of their space to healing outdoor...

Pasha, Samira

2012-07-16T23:59:59.000Z

44

Mobile Phones and Outdoor Advertising: Measurable Advertising  

E-Print Network (OSTI)

Television and newspapers sit at the top of many agency marketing plans, while outdoor advertising stays at the

Quercia, Daniele

45

Oil shale retorted underground  

Science Journals Connector (OSTI)

Oil shale retorted underground ... Low-temperature underground retorting of oil shale produces a crude oil with many attractive properties, Dr. George R. Hill of the University of Utah told a meeting of the American Institute of Mining, Metallurgical, and Petroleum Engineers last week in Los Angeles. ... Typical above-ground retorting of oil shale uses temperatures of 900° to 1100° F. because of the economic need ... ...

1967-02-27T23:59:59.000Z

46

Marine Corps Base Quantico Achieves 85% Savings in Parking Lighting...  

Office of Environmental Management (EM)

by conducting a major overhaul of its outdoor lighting (replacing 2,000 fixtures with LED lights), while boosting safety and security throughout the site. mcbquantico2014.pdf...

47

Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting Basics Lighting Basics Lighting Basics August 15, 2013 - 5:12pm Addthis Text Version There are many different types of artificial lights, all of which have different applications and uses. Types of lighting include: Fluorescent Lighting High-intensity Discharge Lighting Incandescent Lighting LED Lighting Low-pressure Sodium Lighting. Which type is best depends on the application. See the chart below for a comparison of lighting types. Lighting Comparison Chart Lighting Type Efficacy (lumens/watt) Lifetime (hours) Color Rendition Index (CRI) Color Temperature (K) Indoors/Outdoors Fluorescent Straight Tube 30-110 7000-24,000 50-90 (fair to good) 2700-6500 (warm to cold) Indoors/outdoors Compact Fluorescent 50-70 10,000 65-88 (good) 2700-6500 (warm to cold) Indoors/outdoors

48

Reducing Indoor Residential Exposures to Outdoor Pollutants  

NLE Websites -- All DOE Office Websites (Extended Search)

Reducing Indoor Residential Exposures to Outdoor Pollutants Reducing Indoor Residential Exposures to Outdoor Pollutants Title Reducing Indoor Residential Exposures to Outdoor Pollutants Publication Type Journal Article LBNL Report Number LBNL-51758 Year of Publication 2003 Authors Sherman, Max H., and Nance Matson Start Page Chapter Abstract Basic strategy for providing indoor air quality in residences is to dilute indoor sources with outdoor air. This strategy assumes that the outdoor air does not have pollutants at harmful levels or that the outdoor air is, at least, less polluted than the indoor air. When this is not the case, different strategies need to be employed to ensure adequate air quality in the indoor environment. These strategies include ventilation systems, filtration and other measures. These strategies can be used for several types of outdoor pollution, including smog, particulates and toxic air pollutants. This report reviews the impacts that typical outdoor air pollutants can have on the indoor environment and provides design and operational guidance for mitigating them. Poor quality air cannot be used for diluting indoor contaminants, but more generally it can become an indoor contaminant itself. This paper discusses strategies that use the building as protection against potentially hazardous outdoor pollutants, including widespread pollutants, accidental events, and potential attacks

49

Environment - Giant outdoor lab ... | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Environment - Giant outdoor lab ... With the recent completion of a 40-meter observation tower in the nearby Walker Branch Watershed, Oak Ridge National Laboratory researchers are...

50

Animals that Hide Underground  

NLE Websites -- All DOE Office Websites (Extended Search)

Animals that Hide Underground Animals that Hide Underground Nature Bulletin No. 733 November 23, 1963 Forest Preserve District of Cook County Seymour Simon, President David H. Thompson, Senior Naturalist ANIMALS THAT HIDE UNDERGROUND A hole in the ground has an air of mystery about it that rouses our curiosity. No matter whether it is so small that only a worm could squeeze into it, or large enough for a fox den, our questions are much the same. What animal dug the hole? Is it down there now? What is it doing? When will it come out? An underground burrow has several advantages for an animal. In it, many kinds find safety from enemies for themselves and their young. For others, it is an air-conditioned escape from the burning sun of summer and a snug retreat away from the winds and cold of winter. The moist atmosphere of a subterranean home allows the prolonged survival of a wide variety of lower animals which, above the surface, would soon perish from drying.

51

Outdoor Recreation Participation Trends in Texas  

E-Print Network (OSTI)

Outdoor recreation is a popular pastime in Texas. This publication reports on the participation and trends in outdoor recreation in the U.S. and Texas revealed in the National Survey on Recreation and the Environment conducted by the U.S. Forest...

Schuett, Michael A.; Shafer, Carl Scott; Lu, Jiaying

2009-01-06T23:59:59.000Z

52

Princeton University Outdoor Action Sustainability Guide  

E-Print Network (OSTI)

Princeton University Outdoor Action Sustainability Guide #12;Over the past thirty-five years students in the outdoors and how to facilitate team building and positive group interaction. In addition Itinerary ·Defining sustainability ·Princeton's Sustainability Plan ·Focus: fresh water and climate change

53

Thurmont Municipal Light Co | Open Energy Information  

Open Energy Info (EERE)

Thurmont Municipal Light Co Thurmont Municipal Light Co Jump to: navigation, search Name Thurmont Municipal Light Co Place Maryland Utility Id 18901 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png LARGE GENERAL SERVICE Primary Voltage Industrial LARGE GENERAL SERVICE Secondary Voltage Industrial MEDIUM GENERAL SERVICE Industrial OUTDOOR LIGHTING SERVICE(11,000) Lighting OUTDOOR LIGHTING SERVICE(20,000) Lighting OUTDOOR LIGHTING SERVICE(400w) Lighting OUTDOOR LIGHTING SERVICE(7,000) Lighting RESIDENTIAL SERVICE Residential

54

Solid-State Lighting: Text-Alternative Version: Hitting the Target: ENERGY  

NLE Websites -- All DOE Office Websites (Extended Search)

Text-Alternative Version: Text-Alternative Version: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting to someone by E-mail Share Solid-State Lighting: Text-Alternative Version: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting on Facebook Tweet about Solid-State Lighting: Text-Alternative Version: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting on Twitter Bookmark Solid-State Lighting: Text-Alternative Version: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting on Google Bookmark Solid-State Lighting: Text-Alternative Version: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting on Delicious Rank Solid-State Lighting: Text-Alternative Version: Hitting the Target: ENERGY STAR® SSL Outdoor Area Lighting on Digg Find More places to share Solid-State Lighting: Text-Alternative

55

OUTDOOR RECREATION DEMAND AND EXPENDITURES: LOWER SNAKE RIVER RESERVOIRS  

E-Print Network (OSTI)

i OUTDOOR RECREATION DEMAND AND EXPENDITURES: LOWER SNAKE RIVER RESERVOIRS John R. Mc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v SECTION ONE - OUTDOOR RECREATION DEMAND . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Recreation Demand Methods

O'Laughlin, Jay

56

Underground waste barrier structure  

DOE Patents (OSTI)

Disclosed is an underground waste barrier structure that consists of waste material, a first container formed of activated carbonaceous material enclosing the waste material, a second container formed of zeolite enclosing the first container, and clay covering the second container. The underground waste barrier structure is constructed by forming a recessed area within the earth, lining the recessed area with a layer of clay, lining the clay with a layer of zeolite, lining the zeolite with a layer of activated carbonaceous material, placing the waste material within the lined recessed area, forming a ceiling over the waste material of a layer of activated carbonaceous material, a layer of zeolite, and a layer of clay, the layers in the ceiling cojoining with the respective layers forming the walls of the structure, and finally, covering the ceiling with earth.

Saha, Anuj J. (Hamburg, NY); Grant, David C. (Gibsonia, PA)

1988-01-01T23:59:59.000Z

57

Lighting  

SciTech Connect

The lighting section of ASHRAE standard 90.1 is discussed. It applies to all new buildings except low-rise residential, while excluding specialty lighting applications such as signage, art exhibits, theatrical productions, medical and dental tasks, and others. In addition, lighting for indoor plant growth is excluded if designed to operate only between 10 p.m. and 6 a.m. Lighting allowances for the interior of a building are determined by the use of the system performance path unless the space functions are not fully known, such as during the initial stages of design or for speculative buildings. In such cases, the prescriptive path is available. Lighting allowances for the exterior of all buildings are determined by a table of unit power allowances. A new addition the exterior lighting procedure is the inclusion of facade lighting. However, it is no longer possible to trade-off power allotted for the exterior with the interior of a building or vice versa. A significant change is the new emphasis on lighting controls.

McKay, H.N. (Hayden McKay Lighting Design, New York, NY (US))

1990-02-01T23:59:59.000Z

58

Bull Outdoor Products: Order (2015-CE-14014)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered Bull Outdoor Products, Inc. to pay a $8,000 civil penalty after finding Bull had failed to certify that refrigerator basic model BC-130 complies with the applicable energy conservation standards.

59

Underground Injection Control Rule (Vermont)  

Energy.gov (U.S. Department of Energy (DOE))

This rule regulates injection wells, including wells used by generators of hazardous or radioactive wastes, disposal wells within an underground source of drinking water, recovery of geothermal...

60

Underground Storage Tank Program (Vermont)  

Energy.gov (U.S. Department of Energy (DOE))

These rules are intended to protect public health and the environment by establishing standards for the design, installation, operation, maintenance, monitoring, and closure of underground storage...

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Underground Injection Control Regulations (Kansas)  

Energy.gov (U.S. Department of Energy (DOE))

This article prohibits injection of hazardous or radioactive wastes into or above an underground source of drinking water, establishes permit conditions and states regulations for design,...

62

Regulated underground storage tanks  

SciTech Connect

This guidance package is designed to assist DOE Field operations by providing thorough guidance on the underground storage tank (UST) regulations. (40 CFR 280). The guidance uses tables, flowcharts, and checklists to provide a roadmap'' for DOE staff who are responsible for supervising UST operations. This package is tailored to address the issues facing DOE facilities. DOE staff should use this guidance as: An overview of the regulations for UST installation and operation; a comprehensive step-by-step guidance for the process of owning and operating an UST, from installation to closure; and a quick, ready-reference guide for any specific topic concerning UST ownership or operation.

Not Available

1992-06-01T23:59:59.000Z

63

Regulated underground storage tanks  

SciTech Connect

This guidance package is designed to assist DOE Field operations by providing thorough guidance on the underground storage tank (UST) regulations. [40 CFR 280]. The guidance uses tables, flowcharts, and checklists to provide a ``roadmap`` for DOE staff who are responsible for supervising UST operations. This package is tailored to address the issues facing DOE facilities. DOE staff should use this guidance as: An overview of the regulations for UST installation and operation; a comprehensive step-by-step guidance for the process of owning and operating an UST, from installation to closure; and a quick, ready-reference guide for any specific topic concerning UST ownership or operation.

Not Available

1992-06-01T23:59:59.000Z

64

Saving an Underground Reservoir  

E-Print Network (OSTI)

significant part of the region?s agricultural economy. Though the area has few rivers and lakes, underneath it lies a supply of water that has provided groundwater for developing this economy. This underground water, the Ogallala Aquifer, is a finite.... ?We have already seen isolat- ed areas that have no irrigation water remaining and the economy has been crushed.? The region produces about 4 percent of the nation?s corn, 25 percent of the hard red winter wheat, 23 per- cent of the grain sorghum...

Wythe, Kathy

2006-01-01T23:59:59.000Z

65

Underground Gasification of Coal Reported  

Science Journals Connector (OSTI)

Underground Gasification of Coal Reported ... RESULTS of a first step taken toward determining the feasibility of the underground gasification of coal were reported recently to the Interstate Oil Compact Commission by Milton H. Fies, manager of coal operations for the Alabama Power Co. ...

1947-05-12T23:59:59.000Z

66

California Working Natural Gas Underground Storage Capacity ...  

Gasoline and Diesel Fuel Update (EIA)

Working Natural Gas Underground Storage Capacity (Million Cubic Feet) California Working Natural Gas Underground Storage Capacity (Million Cubic Feet) Year Jan Feb Mar Apr May Jun...

67

California Working Natural Gas Underground Storage Capacity ...  

U.S. Energy Information Administration (EIA) Indexed Site

Working Natural Gas Underground Storage Capacity (Million Cubic Feet) California Working Natural Gas Underground Storage Capacity (Million Cubic Feet) Decade Year-0 Year-1 Year-2...

68

Underground—and the City of the Future  

Science Journals Connector (OSTI)

... , warehouses and other public service buildings, as well as traffic routes for vehicles and pedestrians, would be constructed in this way. Already there exists a plan for the diversion ... in the well-known École spéciale d'Architecture, on the lighting of underground traffic and pedestrian routes. He reviews the practice exemplified in some of the short subways in Paris, ...

1940-01-06T23:59:59.000Z

69

Design and Field Testing of an Autonomous Underground Tramming System  

E-Print Network (OSTI)

-haul-dump (LHD) machine is often used to excavate fragmented rock, haul it to an assigned location, and then dump, the hazardous nature of underground envi- ronments, driver safety and fatigue, labor costs, and the cyclic" attempts worked by outfitting the mine with signal- emitting cables [2], light-emitting ropes [1

Paris-Sud XI, Université de

70

Hagerstown Light Department | Open Energy Information  

Open Energy Info (EERE)

Hagerstown Light Department Hagerstown Light Department Jump to: navigation, search Name Hagerstown Light Department Place Maryland Utility Id 7908 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png GENERAL AND COMMERCIAL SERVICE Commercial LIGHT AND POWER SERVICE (HIGH LOAD FACTOR) Industrial LIGHT AND POWER SERVICE (Low Load Factor) Commercial OUTDOOR LIGHTING SERVICE (200 Watts)Fluorescent luminaire Lighting OUTDOOR LIGHTING SERVICE(100 Watts)Fluorescent luminaire Lighting OUTDOOR LIGHTING SERVICE(175 Watts MV)) Lighting

71

Terrain sensing and estimation for dynamic outdoor mobile robots  

E-Print Network (OSTI)

In many applications, mobile robots are required to travel on outdoor terrain at high speed. Compared to traditional low-speed, laboratory-based robots, outdoor scenarios pose increased perception and mobility challenges ...

Ward, Christopher Charles

2007-01-01T23:59:59.000Z

72

Base Natural Gas in Underground Storage (Summary)  

U.S. Energy Information Administration (EIA) Indexed Site

Citygate Price Residential Price Commercial Price Industrial Price Electric Power Price Gross Withdrawals Gross Withdrawals From Gas Wells Gross Withdrawals From Oil Wells Gross Withdrawals From Shale Gas Wells Gross Withdrawals From Coalbed Wells Repressuring Nonhydrocarbon Gases Removed Vented and Flared Marketed Production NGPL Production, Gaseous Equivalent Dry Production Imports By Pipeline LNG Imports Exports Exports By Pipeline LNG Exports Underground Storage Capacity Gas in Underground Storage Base Gas in Underground Storage Working Gas in Underground Storage Underground Storage Injections Underground Storage Withdrawals Underground Storage Net Withdrawals Total Consumption Lease and Plant Fuel Consumption Pipeline & Distribution Use Delivered to Consumers Residential Commercial Industrial Vehicle Fuel Electric Power Period:

73

Investigating leaking underground storage tanks  

E-Print Network (OSTI)

INVESTIGATING LEAKING UNDERGROUND STORAGE TANKS A Thesis by DAVID THOMPSON UPTON Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE August 1989... Major Subject: Geology INVESTIGATING LEAKING UNDERGROUND STORAGE TANKS A Thesis by DAVID THOMPSON UPTON Approved as to sty)e and content by: P. A, Domenico (Chair of Committee) jj K. W. Brown (Member) C. C Mathewson (Member) J. H. S ng Head...

Upton, David Thompson

1989-01-01T23:59:59.000Z

74

Underground pumped hydroelectric storage  

SciTech Connect

Underground pumped hydroelectric energy storage was conceived as a modification of surface pumped storage to eliminate dependence upon fortuitous topography, provide higher hydraulic heads, and reduce environmental concerns. A UPHS plant offers substantial savings in investment cost over coal-fired cycling plants and savings in system production costs over gas turbines. Potential location near load centers lowers transmission costs and line losses. Environmental impact is less than that for a coal-fired cycling plant. The inherent benefits include those of all pumped storage (i.e., rapid load response, emergency capacity, improvement in efficiency as pumps improve, and capacity for voltage regulation). A UPHS plant would be powered by either a coal-fired or nuclear baseload plant. The economic capacity of a UPHS plant would be in the range of 1000 to 3000 MW. This storage level is compatible with the load-leveling requirements of a greater metropolitan area with population of 1 million or more. The technical feasibility of UPHS depends upon excavation of a subterranean powerhouse cavern and reservoir caverns within a competent, impervious rock formation, and upon selection of reliable and efficient turbomachinery - pump-turbines and motor-generators - all remotely operable.

Allen, R.D.; Doherty, T.J.; Kannberg, L.D.

1984-07-01T23:59:59.000Z

75

Underground Facilities, Technological Challenges  

E-Print Network (OSTI)

This report gives a summary overview of the status of international under- ground facilities, in particular as relevant to long-baseline neutrino physics and neutrino astrophysics. The emphasis is on the technical feasibility aspects of creating the large underground infrastructures that will be needed in the fu- ture to house the necessary detectors of 100 kton to 1000 kton scale. There is great potential in Europe to build such a facility, both from the technical point of view and because Europe has a large concentration of the necessary engi- neering and geophysics expertise. The new LAGUNA collaboration has made rapid progress in determining the feasibility for a European site for such a large detector. It is becoming clear in fact that several locations are technically fea- sible in Europe. Combining this with the possibility of a new neutrino beam from CERN suggests a great opportunity for Europe to become the leading centre of neutrino studies, combining both neutrino astrophysics and neutrino beam stu...

Spooner, N

2010-01-01T23:59:59.000Z

76

Light  

Science Journals Connector (OSTI)

Sunlight contains energy which can be directly converted into electricity in solar cells of various types. This is an example of what is called 'direct conversion', involving no moving parts or heat conversion processes. This chapter looks at photovoltaic and photoelectric devices and also at other ideas for using light energy, some of which operate in the infrared part of the spectrum. Solar electric power is a rapidly developing field, opening up many opportunities for novel applications, as well as requirements, including for storage, with one idea being solar-powered hydrogen production and then direct conversion to electricity in fuel cells. Direct conversion is not always efficient, and this chapter introduces the concept of 'energy return on energy invested'. In speculative mood this chapter also looks at the idea of a global grid, allowing daytime solar generation to be used on the night side of the planet.

David Elliott ? Pages 4-1 to 4-20

77

Underground Coal Thermal Treatment  

SciTech Connect

The long-term objective of this work is to develop a transformational energy production technology by insitu thermal treatment of a coal seam for the production of substitute natural gas (SNG) while leaving much of the coalâ??s carbon in the ground. This process converts coal to a high-efficiency, low-GHG emitting gas fuel. It holds the potential of providing environmentally acceptable access to previously unusable coal resources. This topical report discusses the development of experimental capabilities, the collection of available data, and the development of simulation tools to obtain process thermo-chemical and geo-thermal parameters in preparation for the eventual demonstration in a coal seam. It also includes experimental and modeling studies of CO{sub 2} sequestration. Efforts focused on: â?¢ Constructing a suite of three different coal pyrolysis reactors. These reactors offer the ability to gather heat transfer, mass transfer and kinetic data during coal pyrolysis under conditions that mimic in situ conditions (Subtask 6.1). â?¢ Studying the operational parameters for various underground thermal treatment processes for oil shale and coal and completing a design matrix analysis for the underground coal thermal treatment (UCTT). This analysis yielded recommendations for terms of targeted coal rank, well orientation, rubblization, presence of oxygen, temperature, pressure, and heating sources (Subtask 6.2). â?¢ Developing capabilities for simulating UCTT, including modifying the geometry as well as the solution algorithm to achieve long simulation times in a rubblized coal bed by resolving the convective channels occurring in the representative domain (Subtask 6.3). â?¢ Studying the reactive behavior of carbon dioxide (CO{sub 2}) with limestone, sandstone, arkose (a more complex sandstone) and peridotite, including mineralogical changes and brine chemistry for the different initial rock compositions (Subtask 6.4). Arkose exhibited the highest tendency of participating in mineral reactions, which can be attributed to the geochemical complexity of its initial mineral assemblage. In experiments with limestone, continuous dissolution was observed with the release of CO{sub 2} gas, indicated by the increasing pressure in the reactor (formation of a gas chamber). This occurred due to the lack of any source of alkali to buffer the solution. Arkose has the geochemical complexity for permanent sequestration of CO{sub 2} as carbonates and is also relatively abundant. The effect of including NH{sub 3} in the injected gas stream was also investigated in this study. Precipitation of calcite and trace amounts of ammonium zeolites was observed. A batch geochemical model was developed using Geochemists Workbench (GWB). Degassing effect in the experiments was corrected using the sliding fugacity model in GWB. Experimental and simulation results were compared and a reasonable agreement between the two was observed.

P. Smith; M. Deo; E. Eddings; A. Sarofim; K. Gueishen; M. Hradisky; K. Kelly; P. Mandalaparty; H. Zhang

2011-10-30T23:59:59.000Z

78

Underground Storage Technology Consortium  

NLE Websites -- All DOE Office Websites (Extended Search)

U U U N N D D E E R R G G R R O O U U N N D D G G A A S S S S T T O O R R A A G G E E T T E E C C H H N N O O L L O O G G Y Y C C O O N N S S O O R R T T I I U U M M R R & & D D P P R R I I O O R R I I T T Y Y R R E E S S E E A A R R C C H H N N E E E E D D S S WORKSHOP PROCEEDINGS February 3, 2004 Atlanta, Georgia U U n n d d e e r r g g r r o o u u n n d d G G a a s s S S t t o o r r a a g g e e T T e e c c h h n n o o l l o o g g y y C C o o n n s s o o r r t t i i u u m m R R & & D D P P r r i i o o r r i i t t y y R R e e s s e e a a r r c c h h N N e e e e d d s s OVERVIEW As a follow up to the development of the new U.S. Department of Energy-sponsored Underground Gas Storage Technology Consortium through Penn State University (PSU), DOE's National Energy Technology Center (NETL) and PSU held a workshop on February 3, 2004 in Atlanta, GA to identify priority research needs to assist the consortium in developing Requests for Proposal (RFPs). Thirty-seven

79

Kingston Field Underground  

E-Print Network (OSTI)

Walter Light Hall 23 Watson Hall, John 76 Unnamed Buildings 96 Albert Street 63 144 Albert Street 92 148 Albert Street 91 152 Albert Street 90 18 Barrie Street 44 78 Barrie Street 41 82-84 Barrie Street 39 98-102 Barrie Street 36 144 Barrie Street 34 146 Barrie Street 33 162-164 Barrie Street 24 51 Queen's Crescent

Ellis, Randy

80

A Cost Benefit Analysis of California's Leaking Underground Fuel Tanks  

E-Print Network (OSTI)

s Leaking Underground Fuel Tanks (LUFTs)”. Submitted to theCalifornia’s Underground Storage Tank Program”. Submitted tos Leaking Underground Fuel Tanks” by Samantha Carrington

Carrington-Crouch, Robert

1996-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

The TAMU Outdoors Program: a case study  

E-Print Network (OSTI)

for weekend outings. The ORC became a catalyst for bringing students with different skills and experiences together and letting them cooperatively initiate, plan, and implement trips of their choice. By the fiscal year 1979-80, thirty-two trips were taken... with 26 receiving an outdoor leadership certification. A number of these students began leading trips for the ORC. With the arrival of a restrictive financial outlook in all university programs receiving student service fees in fiscal year 1984...

Kott, Patsy L

2012-06-07T23:59:59.000Z

82

Determining Outdoor CPV Cell Temperature: Preprint  

SciTech Connect

An accurate method is needed for determining cell temperature when measuring CPV modules outdoors. It has been suggested that cell temperature can be calculated though a procedure that shutters sunlight to the cells while measuring the transients in open-circuit voltage (Voc) and heat sink temperature. This paper documents application of this shutter procedure to multiple CPV modules at NREL. The challenges and limitations are presented along with an alternate approach to measuring CPV cell operating temperature.

Muller, M.; Deline, C.; Marion, B.; Kurtz, S.; Bosco, N.

2011-07-01T23:59:59.000Z

83

Logistics background study: underground mining  

SciTech Connect

Logistical functions that are normally associated with US underground coal mining are investigated and analyzed. These functions imply all activities and services that support the producing sections of the mine. The report provides a better understanding of how these functions impact coal production in terms of time, cost, and safety. Major underground logistics activities are analyzed and include: transportation and personnel, supplies and equipment; transportation of coal and rock; electrical distribution and communications systems; water handling; hydraulics; and ventilation systems. Recommended areas for future research are identified and prioritized.

Hanslovan, J. J.; Visovsky, R. G.

1982-02-01T23:59:59.000Z

84

Underground Storage Tanks: New Fuels and Compatibility  

Energy.gov (U.S. Department of Energy (DOE))

Breakout Session 1C—Fostering Technology Adoption I: Building the Market for Renewables with High Octane Fuels Underground Storage Tanks: New Fuels and Compatibility Ryan Haerer, Program Analyst, Alternative Fuels, Office of Underground Storage Tanks, Environmental Protection Agency

85

Top 5 Things You Didn't Know About Holiday Lights | Department...  

Office of Environmental Management (EM)

product used in outdoor street and parking lot lighting. While small, this chip is the heart of the light and as of June 2012 was brighter than a 60-watt light bulb. | Photo...

86

High Temperature Superconducting Underground Cable  

SciTech Connect

The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the world’s first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

Farrell, Roger, A.

2010-02-28T23:59:59.000Z

87

Use of Personal-Indoor-Outdoor Sulfur Concentrations to Estimate the Infiltration Factor and Outdoor Exposure Factor for Individual Homes and Persons  

Science Journals Connector (OSTI)

Use of Personal-Indoor-Outdoor Sulfur Concentrations to Estimate the Infiltration Factor and Outdoor Exposure Factor for Individual Homes and Persons ...

Lance Wallace; Ron Williams:?

2005-05-12T23:59:59.000Z

88

Lighting and Dark Sky Regulations  

E-Print Network (OSTI)

.........................................................................................................2 C. Cherokee County, Georgia's Outdoor Lighting and Road Glare Ordinance visited Apr. 0, 2008) (providing links to ordinances throughout the United States). 2 See, e.g. Cherokee Protection Ordinance (Dec. , 200). 5 See, e.g. Model Lighting Section for Zoning Ordinances and Cherokee

Rosemond, Amy Daum

89

Ideal balance of work, play makes outdoor enthusiast's James...  

NLE Websites -- All DOE Office Websites (Extended Search)

balance of work, play makes outdoor enthusiast's James Miller life enviable Nuclear engineer graduate research assistant gets valueable experience while taking advantage of local...

90

ACCESS America's Great Outdoors: Public Lands Are for Everyone!1  

E-Print Network (OSTI)

Universal Access to Outdoor Recreation: A Design Guide. This state-of-the-art design guide is breaking new ground in the area of accessibility by focusing on integrating universal design into all outdoor experience are limited. Historically, recreation facilities and programs were created by traditional design

Standiford, Richard B.

91

NIST Technical Note 1666 Modeling the Effects of Outdoor Gasoline  

E-Print Network (OSTI)

NIST Technical Note 1666 Modeling the Effects of Outdoor Gasoline Powered Generator Use on Indoor Technical Note 1666 Modeling the Effects of Outdoor Gasoline Powered Generator Use on Indoor Carbon Monoxide and Technology (NIST) conducted a study for CDC to examine the impact of distance of gasoline-powered portable

92

Outdoor Outfitter Gets Greener With Solar Water Heater | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater October 8, 2010 - 12:51pm Addthis L.L. Bean’s flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | L.L. Bean's flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | Lindsay Gsell L.L. Bean is known for its outdoor apparel- jackets, backpacks and cozy winter sweaters. However, the company does more than just dress for the outdoors, it also works to protect and preserve it. For nearly 100 years, L.L. Bean has been committed to environmental conservation and

93

Conservation and Outdoor Education in the Schools  

NLE Websites -- All DOE Office Websites (Extended Search)

Education in the Schools Education in the Schools Nature Bulletin No. 374-A March 21, 1970 Forest Preserve District of Cook County George W. Dunne, President Roland F. Eisenbeis, Supt. of Conservation CONSERVATION AND OUTDOOR EDUCATION IN THE SCHOOLS Given a favorable climate, two things make and keep a nation great: its people and its natural resources. The well-being of our nation depends upon the wise use of those resources. They provide our basic requirements -- food, clothing and shelter. There is ample evidence that a very large portion of all teachers recognize the need for conservation and the importance of environmental education. Leading educators say that teachers realize the why of conservation but need help with the what, when, where and how -- how to teach the topic so that it hooks onto the personal lives of their students and is translated into behavior -- how to bring conservation home to all pupils in terms of day-to-day living.

94

Midwest Underground Technology | Open Energy Information  

Open Energy Info (EERE)

Underground Technology Underground Technology Jump to: navigation, search Name Midwest Underground Technology Facility Midwest Underground Technology Sector Wind energy Facility Type Small Scale Wind Facility Status In Service Owner Midwest Underground Technology Energy Purchaser Midwest Underground Technology Location Champaign IL Coordinates 40.15020987°, -88.29149723° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.15020987,"lon":-88.29149723,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

95

Predictive clothing insulation model based on outdoor air and indoor operative temperatures  

E-Print Network (OSTI)

2012) Predictive clothing insulation model based on outdoorPredictive clothing insulation model based on outdoor airpredictive models of clothing insulation have been developed

Schiavon, Stefano; Lee, Kwang Ho

2012-01-01T23:59:59.000Z

96

Might underground waste repositories blow up?  

SciTech Connect

Some writers have presented possible scenarios in which a subcritical underground deposit of plutonium or other fissile material might be changed into a critical configuration. The underground criticalities that occurred in Gabon some 1.7 billion years ago in deposits of natural uranium is cited. Other scientists assert that it is virtually impossible that such a configuration could develop in an underground repository. The author presents the pros and cons of these views. 5 refs.

Hippel, F. von [Princeton Univ., NJ (United States)

1996-03-01T23:59:59.000Z

97

Underground Storage Tank Regulations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Underground Storage Tank Regulations Underground Storage Tank Regulations Underground Storage Tank Regulations < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Program Info State Mississippi Program Type Environmental Regulations Siting and Permitting Provider Department of Environmental Quality The Underground Storage Tank Regulations is relevant to all energy projects

98

Unsteady heat losses of underground pipelines  

Science Journals Connector (OSTI)

Analytic expressions are presented for the unsteady temperature distribution of the ground and heat losses of an underground pipeline for an arbitrary...

B. L. Krivoshein; V. M. Agapkin

1977-08-01T23:59:59.000Z

99

,"Underground Natural Gas Storage - All Operators"  

U.S. Energy Information Administration (EIA) Indexed Site

Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","Underground Natural Gas Storage - All Operators",8,"Monthly","102014","1151973" ,"Release...

100

Pipelines and Underground Gas Storage (Iowa)  

Energy.gov (U.S. Department of Energy (DOE))

These rules apply to intrastate transport of natural gas and other substances via pipeline, as well as underground gas storage facilities. The construction and operation of such infrastructure...

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

,"California Underground Natural Gas Storage - All Operators...  

U.S. Energy Information Administration (EIA) Indexed Site

Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","California Underground Natural Gas Storage - All Operators",3,"Annual",2013,"6301967"...

102

,"California Underground Natural Gas Storage Capacity"  

U.S. Energy Information Administration (EIA) Indexed Site

Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","California Underground Natural Gas Storage Capacity",12,"Annual",2013,"6301988" ,"Release...

103

Cryogenic slurry for extinguishing underground fires  

DOE Patents (OSTI)

A cryogenic slurry comprising a mixture of solid carbon dioxide particles suspended in liquid nitrogen is provided which is useful in extinguishing underground fires.

Chaiken, Robert F. (Pittsburgh, PA); Kim, Ann G. (Pittsburgh, PA); Kociban, Andrew M. (Wheeling, WV); Slivon, Jr., Joseph P. (Tarentum, PA)

1994-01-01T23:59:59.000Z

104

,"New York Underground Natural Gas Storage Capacity"  

U.S. Energy Information Administration (EIA) Indexed Site

Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","New York Underground Natural Gas Storage Capacity",11,"Annual",2013,"6301988" ,"Release...

105

Hawaii Underground Injection Control Permitting Webpage | Open...  

Open Energy Info (EERE)

Webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Hawaii Underground Injection Control Permitting Webpage Author State of Hawaii Department of...

106

,"Colorado Underground Natural Gas Storage - All Operators"  

U.S. Energy Information Administration (EIA) Indexed Site

"Sourcekey","N5030CO2","N5010CO2","N5020CO2","N5070CO2","N5050CO2","N5060CO2" "Date","Colorado Natural Gas Underground Storage Volume (MMcf)","Colorado Natural Gas in Underground...

107

,"Underground Natural Gas Storage by Storage Type"  

U.S. Energy Information Administration (EIA) Indexed Site

Sourcekey","N5030US2","N5010US2","N5020US2","N5070US2","N5050US2","N5060US2" "Date","U.S. Natural Gas Underground Storage Volume (MMcf)","U.S. Total Natural Gas in Underground...

108

Carbon Allocation in Underground Storage Organs  

E-Print Network (OSTI)

Carbon Allocation in Underground Storage Organs Studies on Accumulation of Starch, Sugars and Oil Cover: Starch granules in cells of fresh potato tuber visualised by iodine staining. #12;Carbon By increasing knowledge of carbon allocation in underground storage organs and using the knowledge to improve

109

Utah Underground Storage Tank Installation Permit | Open Energy...  

Open Energy Info (EERE)

Underground Storage Tank Installation Permit Jump to: navigation, search OpenEI Reference LibraryAdd to library Form: Utah Underground Storage Tank Installation Permit Form Type...

110

Colorado Working Natural Gas Underground Storage Capacity (Million...  

Annual Energy Outlook 2012 (EIA)

Working Natural Gas Underground Storage Capacity (Million Cubic Feet) Colorado Working Natural Gas Underground Storage Capacity (Million Cubic Feet) Year Jan Feb Mar Apr May Jun...

111

Progress Continues Toward Closure of Two Underground Waste Tanks...  

Office of Environmental Management (EM)

Progress Continues Toward Closure of Two Underground Waste Tanks at Savannah River Site Progress Continues Toward Closure of Two Underground Waste Tanks at Savannah River Site...

112

The Simulation Analysis of Fire Feature on Underground Substation  

Science Journals Connector (OSTI)

Underground transformer substations constructed with non-dwelling buildings have a ... out simulation analysis of fire feature on underground substation. The corresponding fire protection strategy is also...

Xin Han; Xie He; Beihua Cong

2012-01-01T23:59:59.000Z

113

California Natural Gas Count of Underground Storage Capacity...  

U.S. Energy Information Administration (EIA) Indexed Site

Count of Underground Storage Capacity (Number of Elements) California Natural Gas Count of Underground Storage Capacity (Number of Elements) Decade Year-0 Year-1 Year-2 Year-3...

114

DOE - Office of Legacy Management -- Hoe Creek Underground Coal...  

Office of Legacy Management (LM)

Hoe Creek Underground Coal Gasification Site - 045 FUSRAP Considered Sites Site: Hoe Creek Underground Coal Gasification Site (045) Designated Name: Alternate Name: Location:...

115

Solar lighting | Open Energy Information  

Open Energy Info (EERE)

lighting lighting Jump to: navigation, search Introductory Facts About Solar Lights It is not just a normal light bulb.The solar light consists of a LED or Light Emitting Diode, which draw little power. Coupled with constantly recharging batteries, you will never run out of light! They will save the customer money. By Replacing all outdoor lighting with solar lights there is no need to plug in to the electrical system. The lights will automatically turn on at dusk and will be charged during the day. They help out the environment.Not only does not plugging in to the power system save money but also energy, therefore protecting the Earth. Easy to Install No wires necessary, just pop in the battery. They come in all designs Just because they are solar lights doesn't

116

EXPERIMENTS, CONCEPTUAL DESIGN, PRELIMINARY COST ESTIMATES AND SCHEDULES FOR AN UNDERGROUND RESEARCH FACILITY  

E-Print Network (OSTI)

surface and underground facilities as we11 as operation andconstruction of the underground facility. However, because

Korbin, G.

2010-01-01T23:59:59.000Z

117

Seismic verification of underground explosions  

SciTech Connect

The first nuclear test agreement, the test moratorium, was made in 1958 and lasted until the Soviet Union unilaterally resumed testing in the atmosphere in 1961. It was followed by the Limited Test Ban Treaty of 1963, which prohibited nuclear tests in the atmosphere, in outer space, and underwater. In 1974 the Threshold Test Ban Treaty (TTBT) was signed, limiting underground tests after March 1976 to a maximum yield of 250 kt. The TTBT was followed by a treaty limiting peaceful nuclear explosions and both the United States and the Soviet Union claim to be abiding by the 150-kt yield limit. A comprehensive test ban treaty (CTBT), prohibiting all testing of nuclear weapons, has also been discussed. However, a verifiable CTBT is a contradiction in terms. No monitoring technology can offer absolute assurance that very-low-yield illicit explosions have not occurred. The verification process, evasion opportunities, and cavity decoupling are discussed in this paper.

Glenn, L.A.

1985-06-01T23:59:59.000Z

118

Depleted Argon from Underground Sources  

SciTech Connect

Argon is a strong scintillator and an ideal target for Dark Matter detection; however {sup 39}Ar contamination in atmospheric argon from cosmic ray interactions limits the size of liquid argon dark matter detectors due to pile-up. Argon from deep underground is depleted in {sup 39}Ar due to the cosmic ray shielding of the earth. In Cortez, Colorado, a CO{sub 2} well has been discovered to contain approximately 600 ppm of argon as a contamination in the CO{sub 2}. We first concentrate the argon locally to 3% in an Ar, N{sub 2}, and He mixture, from the CO{sub 2} through chromatographic gas separation, and then the N{sub 2} and He will be removed by continuous distillation to purify the argon. We have collected 26 kg of argon from the CO{sub 2} facility and a cryogenic distillation column is under construction at Fermilab to further purify the argon.

Back, H. O.; Galbiati, C.; Goretti, A.; Loer, B.; Montanari, D.; Mosteiro, P. [Department of Physics, Princeton University, Jadwin Hall, Princeton, NJ 08544 (United States); Alexander, T.; Alton, A.; Rogers, H. [Augustana College, Physics Department, 2001 South Summit Ave., Sioux Fall, SD 57197 (United States); Kendziora, C.; Pordes, S. [Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, IL 60510 (United States)

2011-04-27T23:59:59.000Z

119

Airborne Particles in Outdoor Air: Atmospheric Dust  

Science Journals Connector (OSTI)

For industrial products, in addition to the harmful effect like usual particles, the particular harmful effect of atmospheric dust especially metal particles is very large. For example, the light metal element...

Zhonglin Xu

2014-01-01T23:59:59.000Z

120

Use of Personal-Indoor-Outdoor Sulfur Concentrations to Estimate the Infiltration Factor and Outdoor Exposure Factor for Individual Homes and Persons  

Science Journals Connector (OSTI)

Use of Personal-Indoor-Outdoor Sulfur Concentrations to Estimate the Infiltration Factor and Outdoor Exposure Factor for Individual Homes and Persons ... Indoor?outdoor comparisons of sulfur concentrations thus provide a direct way to estimate Finf for each individual home. ... Of 36 homes, 22 had intercepts not significantly different from zero, indicating no apparent source of sulfur in the home. ...

Lance Wallace; Ron Williams

2005-01-26T23:59:59.000Z

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Natural Gas Withdrawals from Underground Storage (Annual Supply &  

U.S. Energy Information Administration (EIA) Indexed Site

Citygate Price Residential Price Commercial Price Industrial Price Electric Power Price Gross Withdrawals Gross Withdrawals From Gas Wells Gross Withdrawals From Oil Wells Gross Withdrawals From Shale Gas Wells Gross Withdrawals From Coalbed Wells Repressuring Nonhydrocarbon Gases Removed Vented and Flared Marketed Production NGPL Production, Gaseous Equivalent Dry Production Imports By Pipeline LNG Imports Exports Exports By Pipeline LNG Exports Underground Storage Capacity Gas in Underground Storage Base Gas in Underground Storage Working Gas in Underground Storage Underground Storage Injections Underground Storage Withdrawals Underground Storage Net Withdrawals Total Consumption Lease and Plant Fuel Consumption Pipeline & Distribution Use Delivered to Consumers Residential Commercial Industrial Vehicle Fuel Electric Power Period: Monthly Annual

122

Underground Coal Gasification in the USSR  

Science Journals Connector (OSTI)

By accomplishing in a single operation the extraction of coal and its conversion into a gaseous fuel, underground gasification makes it possible to avoid the heavy capital investments required for coal gasification

1983-01-01T23:59:59.000Z

123

Best practices for underground diesel emissions  

SciTech Connect

The US NIOSH and the Coal Diesel Partnership recommend practices for successfully using ceramic filters to control particulate emitted from diesel-powered equipment used in underground coal mines. 3 tabs.

Patts, L.; Brnich, M. Jr. [NIOSH Pittsburgh Research Laboratory, Pittsburgh, PA (United States)

2007-08-15T23:59:59.000Z

124

Underground Storage of Natural Gas (Kansas)  

Energy.gov (U.S. Department of Energy (DOE))

Any natural gas public utility may appropriate for its use for the underground storage of natural gas any subsurface stratum or formation in any land which the commission shall have found to be...

125

UEME : the underground electronic music experience  

E-Print Network (OSTI)

The global electronic music scene has remained underground for its entire lifespan, momentarily materializing during an event, a place defined by the music performed and the people who desire the experience. As festivals ...

Ciraulo, Christopher Samuel

2005-01-01T23:59:59.000Z

126

Underground Natural Gas Storage Capacity  

Gasoline and Diesel Fuel Update (EIA)

. . Underground Natural Gas Storage Capacity by State, December 31, 1996 (Capacity in Billion Cubic Feet) Table State Interstate Companies Intrastate Companies Independent Companies Total Number of Active Fields Capacity Number of Active Fields Capacity Number of Active Fields Capacity Number of Active Fields Capacity Percent of U.S. Capacity Alabama................. 0 0 1 3 0 0 1 3 0.04 Arkansas ................ 0 0 3 32 0 0 3 32 0.40 California................ 0 0 10 470 0 0 10 470 5.89 Colorado ................ 4 66 5 34 0 0 9 100 1.25 Illinois ..................... 6 259 24 639 0 0 30 898 11.26 Indiana ................... 6 16 22 97 0 0 28 113 1.42 Iowa ....................... 4 270 0 0 0 0 4 270 3.39 Kansas ................... 16 279 2 6 0 0 18 285 3.57 Kentucky ................ 6 167 18 49 0 0 24 216 2.71 Louisiana................ 8 530 4 25 0 0 12 555 6.95 Maryland ................ 1 62

127

Depleted argon from underground sources  

SciTech Connect

Argon is a powerful scintillator and an excellent medium for detection of ionization. Its high discrimination power against minimum ionization tracks, in favor of selection of nuclear recoils, makes it an attractive medium for direct detection of WIMP dark matter. However, cosmogenic {sup 39}Ar contamination in atmospheric argon limits the size of liquid argon dark matter detectors due to pile-up. The cosmic ray shielding by the earth means that Argon from deep underground is depleted in {sup 39}Ar. In Cortez Colorado a CO{sub 2} well has been discovered to contain approximately 500ppm of argon as a contamination in the CO{sub 2}. In order to produce argon for dark matter detectors we first concentrate the argon locally to 3-5% in an Ar, N{sub 2}, and He mixture, from the CO{sub 2} through chromatographic gas separation. The N{sub 2} and He will be removed by continuous cryogenic distillation in the Cryogenic Distillation Column recently built at Fermilab. In this talk we will discuss the entire extraction and purification process; with emphasis on the recent commissioning and initial performance of the cryogenic distillation column purification.

Back, H.O.; /Princeton U.; Alton, A.; /Augustana U. Coll.; Calaprice, F.; Galbiati, C.; Goretti, A.; /Princeton U.; Kendziora, C.; /Fermilab; Loer, B.; /Princeton U.; Montanari, D.; /Fermilab; Mosteiro, P.; /Princeton U.; Pordes, S.; /Fermilab

2011-09-01T23:59:59.000Z

128

Underground ventilation remote monitoring and control system  

SciTech Connect

This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system.

Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.

1995-12-31T23:59:59.000Z

129

Marine Corps Base Quantico Achieves 85% Savings in Parking Lighting  

Energy.gov (U.S. Department of Energy (DOE))

Document provides an overview of how the Marine Corps Base Quantico (MCBQ) achieved 85% energy savings in parking lighting by conducting a major overhaul of its outdoor lighting (replacing 2,000 fixtures with LED lights), while boosting safety and security throughout the site.

130

Light and sound underground: a study of rave culture  

E-Print Network (OSTI)

-before-seen level of hedonistic insanity. Illegal sampling grew to a rampant height, the hardcore scene introducing a cut-up outlaw culture of bootleg music and pirate radio. Prodigy's 1991 smash "Charly, '* with its samples from kids TV shows, embodied... of the scene surrounding the music took place in Britain (and other European countries) was rave itsell imported back to the U. S. The states did have an early Ecstasy scene in Austin and Dallas nightclubs, where patrons could buy the drug until made illegal...

Harrison, Summer Gioia

2013-02-22T23:59:59.000Z

131

Indoor and Outdoor Spectroradiometer Intercomparison for Spectral Irradiance Measurement  

SciTech Connect

This report details the global spectral irradiance intercomparison using spectroradiometers that was organized by the National Renewable Energy Laboratory's Solar Radiation Research Laboratory. The intercomparison was performed both indoors and outdoors on September 17, 2013. Five laboratories participated in the intercomparison using 10 spectroradiometers, and a coordinated measurement setup and a common platform were employed to compare spectral irradiances under both indoor and outdoor conditions. The intercomparison aimed to understand the performance of the different spectroradiometers and to share knowledge in making spectral irradiance measurements. This intercomparison was the first of its kind in the United States.

Habte, A.; Andreas, A.; Ottoson, L.; Gueymard, C.; Fedor, G.; Fowler, S.; Peterson, J.; Naranen, R.; Kobashi, T.; Akiyama, A.; Takagi, S.

2014-05-01T23:59:59.000Z

132

Information Resources: Pedestrian-Friendly Nighttime Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

Pedestrian-Friendly Nighttime Lighting Pedestrian-Friendly Nighttime Lighting This November 19, 2013 webinar presented issues and considerations related to pedestrian-friendly nighttime lighting, such as color rendering, safety, and adaptation. When it comes to outdoor lighting, the industry has understandably focused on footcandles and uniformity, efficacy, pole spacing, and cutoff-but those are not the chief criteria for all neighborhoods. Presenter Naomi Miller of Pacific Northwest National Laboratory discussed the types of communities and spaces that should consider pedestrian-friendly outdoor lighting, what pedestrian-friendly lighting looks like, the basic principles of glare control, color and visibility, and metrics. View the presentation slides View the text-alternative version

133

A Comparison of Popular Remedial Technologies for Petroleum Contaminated Soils from Leaking Underground Storage Tanks  

E-Print Network (OSTI)

Underground Storage Tanks. Chelsea: Lewis Publishers.and Underground Storage Tank Sites. Database on-line.Michigan Underground Storage Tank Rules. Database on-line.

Kujat, Jonathon D.

1999-01-01T23:59:59.000Z

134

Assessing the Effectiveness of California's Underground Storage Tank Annual Inspection Rate Requirements  

E-Print Network (OSTI)

Leaks from Underground Storage Tanks by Media Affected Soilfrom Underground Storage Tank Facilities Cities CountiesCities Counties Leaks per Underground Storage Tank Facility

Cutter, W. Bowman

2008-01-01T23:59:59.000Z

135

E-Print Network 3.0 - amchitka underground nuclear Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

underground nuclear Search Powered by Explorit Topic List Advanced Search Sample search results for: amchitka underground nuclear Page: << < 1 2 3 4 5 > >> 1 Underground Nuclear...

136

SEARCH FOR UNDERGROUND OPENINGS FOR IN SITU TEST FACILITIES IN CRYSTALLINE ROCK  

E-Print Network (OSTI)

Helms Underground Powerhouse - Pumped storage project Figurelayout of underground powerhouse complex—Helms Pumped57. Helms Underground Powerhouse Pumped Storage Project

Wallenberg, H.A.

2010-01-01T23:59:59.000Z

137

The Basics of Underground Natural Gas Storage  

Gasoline and Diesel Fuel Update (EIA)

Analysis > The Basics of Underground Natural Gas Storage Analysis > The Basics of Underground Natural Gas Storage The Basics of Underground Natural Gas Storage Latest update: August 2004 Printer-Friendly Version Natural gas-a colorless, odorless, gaseous hydrocarbon-may be stored in a number of different ways. It is most commonly held in inventory underground under pressure in three types of facilities. These are: (1) depleted reservoirs in oil and/or gas fields, (2) aquifers, and (3) salt cavern formations. (Natural gas is also stored in liquid form in above-ground tanks. A discussion of liquefied natural gas (LNG) is beyond the scope of this report. For more information about LNG, please see the EIA report, The Global Liquefied Natural Gas Market: Status & Outlook.) Each storage type has its own physical characteristics (porosity, permeability, retention capability) and economics (site preparation and maintenance costs, deliverability rates, and cycling capability), which govern its suitability to particular applications. Two of the most important characteristics of an underground storage reservoir are its capacity to hold natural gas for future use and the rate at which gas inventory can be withdrawn-its deliverability rate (see Storage Measures, below, for key definitions).

138

The Measured Energy Impact of Infiltration in an Outdoor Test Cell  

E-Print Network (OSTI)

of these studies quantified energy loss reduction under a variety of outdoor weather conditions. The energy performance was investigated in an outdoor test cell with different leakage configurations and air flow rates under both infiltration and exfiltration...

Liu, M.; Claridge, D. E.

139

Assessing Sheltering-In-Place Responses to Outdoor Toxic Releases  

NLE Websites -- All DOE Office Websites (Extended Search)

Assessing Sheltering-In-Place Responses to Outdoor Toxic Releases Assessing Sheltering-In-Place Responses to Outdoor Toxic Releases Title Assessing Sheltering-In-Place Responses to Outdoor Toxic Releases Publication Type Conference Proceedings Year of Publication 2005 Authors Sohn, Michael D., Richard G. Sextro, and David M. Lorenzetti Conference Name 10th International Conference on Indoor Air Quality and Climate - Indoor Air 2005 Volume 2(6) Pagination 1792-1796 Date Published Sept. 4-9, 2005 Publisher Tsinghua University Press Conference Location Beijing, China Keywords airflow and pollutant transport group, airflow modeling, comis, countermeasures to chemical and biological threats, emergency response, exposure, indoor environment department, shelter-in-place Abstract An accidental or intentional outdoor release of pollutants can produce a hazardous plume, potentially contaminating large portions of a metropolitan area as it disperses downwind. To minimize health consequences on the populace, government and research organizations often recommend sheltering in place when evacuation is impractical. Some reports also recommend "hardening" an indoor shelter, for example by applying duct tape to prevent leakage into a bathroom. However, few studies have quantified the perceived beneficial effects of sheltering and hardening, or examined the limits of their applicability. In this paper, we examine how sheltering and hardening might reduce exposure levels under different building and meteorological conditions (e.g., wind direction). We predict concentrations and exposure levels for several conditions, and discuss the net benefits from several sheltering and hardening options

140

Outdoor Virtual Reality Bruce H. Thomas and Wayne Piekarski  

E-Print Network (OSTI)

Outdoor Virtual Reality Bruce H. Thomas and Wayne Piekarski Wearable Computer Laboratory University of South Australia Mawson Lakes, SA 5095 Australia Bruce.Thomas@unisa.edu.au Wayne@cs.unisa.edu.au ABSTRACT or augmented beyond the user's normal experience, and increase understanding 226Copyright held by the author

Thomas, Bruce

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

OUTDOOR EDUCATION SUBJECT GUIDE -I/S STORY TELLING  

E-Print Network (OSTI)

OUTDOOR EDUCATION SUBJECT GUIDE - I/S Books: STORY TELLING: A to Zoo: subject access to picture ­ sustainable forestry) #12;EcoKids: raising children who care for the earth/ Dan Chiras GE70 .C52 2005 (The: a comprehensive guide to global issues and sustainable solutions NewTexts: GE70 . W54 2005 Multimedia: Videos

Abolmaesumi, Purang

142

Long-Term Observations of Indoor and Outdoor Radon Concentrations  

Science Journals Connector (OSTI)

......Radiation Protection Dosimetry Article Long-Term Observations of Indoor and Outdoor...Lapere Two sets of data obtained by long-term observations of radon concentration...phosphogypsum was used. Around a nuclear waste storage place containing radium, 22 dosemeters......

J. Uyttenhove; R. Lapere

1988-08-01T23:59:59.000Z

143

Stereo-Vision-Based Obstacle Avoidance in Rough Outdoor Terrain  

E-Print Network (OSTI)

on chemical or nuclear plants are only a few possible scenarios. Unmanned vehicles could patrol frontiers and powerful robot navigation system for rough and vegetated outdoor terrain. Vegetation in that context of natural disasters, large-scale accidents and terrorism. Fire infernos, hurricanes, air crashes and attacks

Berns, Karsten

144

The Basics of Underground Natural Gas Storage  

Gasoline and Diesel Fuel Update (EIA)

The Basics of Underground Natural Gas Storage The Basics of Underground Natural Gas Storage Latest update: August 2004 Natural gas-a colorless, odorless, gaseous hydrocarbon-may be stored in a number of different ways. It is most commonly held in inventory underground under pressure in three types of facilities. These are: (1) depleted reservoirs in oil and/or gas fields, (2) aquifers, and (3) salt cavern formations. (Natural gas is also stored in liquid form in above-ground tanks. A discussion of liquefied natural gas (LNG) is beyond the scope of this report. For more information about LNG, please see the EIA report, The Global Liquefied Natural Gas Market: Status & Outlook.) Each storage type has its own physical characteristics (porosity, permeability, retention capability) and economics (site preparation and

145

Method for making generally cylindrical underground openings  

DOE Patents (OSTI)

A rapid, economical and safe method for making a generally cylindrical underground opening such as a shaft or a tunnel is described. A borehole is formed along the approximate center line of where it is desired to make the underground opening. The borehole is loaded with an explodable material and the explodable material is detonated. An enlarged cavity is formed by the explosive action of the detonated explodable material forcing outward and compacting the original walls of the borehole. The enlarged cavity may be increased in size by loading it with a second explodable material, and detonating the second explodable material. The process may be repeated as required until the desired underground opening is made. The explodable material used in the method may be free-flowing, and it may be contained in a pipe.

Routh, J.W.

1983-05-26T23:59:59.000Z

146

DOE Science Showcase - Light-emitting Diode (LED) Lighting Research | OSTI,  

Office of Scientific and Technical Information (OSTI)

Science Showcase - Light-emitting Diode (LED) Lighting Research Science Showcase - Light-emitting Diode (LED) Lighting Research Light-emitting diode (LED) lighting is a type of solid-state lighting that uses a semiconductor to convert electricity to light. LED lighting products are beginning to appear in a wide variety of home, business, and industrial products such as holiday lighting, replacement bulbs for incandescent lamps, street lighting, outdoor area lighting and indoor ambient lighting. Over the past decade, LED technology research and development supported by the U.S. Department of Energy (DOE) has yielded impressive improvements in the cost, color performance, light output, efficacy, reliability, lifetime, and manufacturability of LED products and this upward trend is expected to continue. Read about the latest DOE research, the technology behind LEDs,

147

Underground Facilities Information (Iowa) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Facilities Information (Iowa) Facilities Information (Iowa) Underground Facilities Information (Iowa) < Back Eligibility Agricultural Commercial Construction Fuel Distributor Industrial Installer/Contractor Institutional Investor-Owned Utility Low-Income Residential Multi-Family Residential Municipal/Public Utility Residential Transportation Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Solar Wind Program Info State Iowa Program Type Environmental Regulations Provider Iowa Utilities Board This section applies to any excavation which may impact underground facilities, including those used for the conveyance of electricity or the transportation of hazardous liquids or natural gas. Excavation is prohibited unless notification takes place, as described in this chapter

148

Underground Injection Control Permits and Registrations (Texas) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Underground Injection Control Permits and Registrations (Texas) Underground Injection Control Permits and Registrations (Texas) < Back Eligibility Utility Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Installer/Contractor Rural Electric Cooperative Fuel Distributor Savings Category Buying & Making Electricity Program Info State Texas Program Type Environmental Regulations Safety and Operational Guidelines Provider Texas Commission on Environmental Quality Chapter 27 of the Texas Water Code (the Injection Well Act) defines an "injection well" as "an artificial excavation or opening in the ground made by digging, boring, drilling, jetting, driving, or some other

149

Notification for Underground Storage Tanks (EPA Form 7530-1)...  

Open Energy Info (EERE)

Notification for Underground Storage Tanks (EPA Form 7530-1) Jump to: navigation, search OpenEI Reference LibraryAdd to library Form: Notification for Underground Storage Tanks...

150

Visit to the Deep Underground Science and Engineering Laboratory  

ScienceCinema (OSTI)

U.S. Department of Energy scientists and administrators join members of the National Science Foundation and South Dakotas Sanford Underground Laboratory for the deepest journey yet to the proposed site of the Deep Underground Science and Engineering Laboratory (DUSEL).

None

2010-01-08T23:59:59.000Z

151

Ground Motions from and House Response to Underground Aggregate Mining  

E-Print Network (OSTI)

interest because many urban quarries have gone underground or are considering doing so. Three cracks were to determine future blasting controls for a underground aggregate quarry near Franklin, KY (Revey, 2005

152

Rectifiers used on the London Underground Railways  

Science Journals Connector (OSTI)

... Lunn to the Institution of Electrical Engftieers on November 7, a description of the rectifier substations is given and also much useful information of the working of these rectifiers for traction ... there is little vibration; but in these respects the rectifier is much superior. The substation buildings for operating the traction system of the London Underground are in very densely populated ...

1935-11-30T23:59:59.000Z

153

Underground natural gas storage reservoir management  

SciTech Connect

The objective of this study is to research technologies and methodologies that will reduce the costs associated with the operation and maintenance of underground natural gas storage. This effort will include a survey of public information to determine the amount of natural gas lost from underground storage fields, determine the causes of this lost gas, and develop strategies and remedial designs to reduce or stop the gas loss from selected fields. Phase I includes a detailed survey of US natural gas storage reservoirs to determine the actual amount of natural gas annually lost from underground storage fields. These reservoirs will be ranked, the resultant will include the amount of gas and revenue annually lost. The results will be analyzed in conjunction with the type (geologic) of storage reservoirs to determine the significance and impact of the gas loss. A report of the work accomplished will be prepared. The report will include: (1) a summary list by geologic type of US gas storage reservoirs and their annual underground gas storage losses in ft{sup 3}; (2) a rank by geologic classifications as to the amount of gas lost and the resultant lost revenue; and (3) show the level of significance and impact of the losses by geologic type. Concurrently, the amount of storage activity has increased in conjunction with the net increase of natural gas imports as shown on Figure No. 3. Storage is playing an ever increasing importance in supplying the domestic energy requirements.

Ortiz, I.; Anthony, R.

1995-06-01T23:59:59.000Z

154

The Public Perceptions of Underground Coal Gasification (UCG)  

E-Print Network (OSTI)

The Public Perceptions of Underground Coal Gasification (UCG): A Pilot Study Simon Shackley #12;The Public Perceptions of Underground Coal Gasification (UCG): A Pilot Study Dr Simon Shackley of Underground Coal Gasification (UCG) in the United Kingdom. The objectives were to identify the main dangers

Watson, Andrew

155

Detection of Underground Marlpit Quarries Using High Resolution Seismic  

E-Print Network (OSTI)

Detection of Underground Marlpit Quarries Using High Resolution Seismic B. Piwakowski* (Ecole of high resolution reflection seismic for the detection and location of underground marlpit quarries of the geological structure, the results show that the detection of marlpit underground quarries, often considered

Boyer, Edmond

156

Health Relevant Outdoor Air Change Rates in Homes  

NLE Websites -- All DOE Office Websites (Extended Search)

Health Relevant Outdoor Air Change Rates in Homes Health Relevant Outdoor Air Change Rates in Homes Speaker(s): Jan Sundell Date: February 6, 2003 - 12:00pm Location: Bldg. 90 The Damp Building and Health (DBH) study started as a cross-sectional questionnaire study of all 14000 children, 1-6 years of age in Värmland, Sweden. The response rate on the questionnaire (year 2001) was 79%, meaning that basic data exists on almost 12,000 children and their homes. In a second step a case-control study on 200 sick (wheezing, asthma, excema), and 200 healthy children, extensive measurements in the home, as well as clinical examinations of the children has been conducted during 2002. Ventilation has been measured with a passive tracer gas method during one week. The results will be presented in this seminar-- seemingly sick

157

National Parks Move Transportation Forward in America's Great Outdoors |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Parks Move Transportation Forward in America's Great Parks Move Transportation Forward in America's Great Outdoors National Parks Move Transportation Forward in America's Great Outdoors March 28, 2013 - 3:00pm Addthis Together, the five newest National Parks Initiative projects will save the equivalent of nearly 10,000 gallons of gasoline and 71 tons of greenhouse gas emissions per year. | Infographic by Sarah Gerrity, Energy Department. Together, the five newest National Parks Initiative projects will save the equivalent of nearly 10,000 gallons of gasoline and 71 tons of greenhouse gas emissions per year. | Infographic by Sarah Gerrity, Energy Department. Shannon Brescher Shea Communications Manager, Clean Cities Program What are the key facts? The five new National Parks Initiative projects will save the

158

From rhetoric to knowledge based actions – Challenges for outdoor recreation management in Sweden  

Science Journals Connector (OSTI)

Abstract This paper investigates how outdoor recreation is considered in the context of strong biodiversity conservation ambitions, and discusses the challenges associated with outdoor recreation management in two protected areas in Sweden. The research employs qualitative techniques such as interviews with key actors and examinations of documents. The results show that while the two planning processes show a sincere engagement and effort spent on outdoor recreation management, no clear strategies for or systematic treatment of outdoor recreation became apparent. Worse, clear deficits in knowledge and relevant competences have been identified, and generally available scientific knowledge about outdoor recreation has not been utilized. Concerns of outdoor recreation are typically addressed by biologists, instead of professionals with training in any of the social sciences or planning disciplines. Apparently these fundamental deficiencies with regards to outdoor recreation can only be improved if it is recognized as a land use interest in its own right. In order to improve management and planning processes, outdoor recreation needs to be institutionalized, and receive its own management guidelines and formal process agendas. Management implications The consideration of outdoor recreation in Sweden’s landscapes and protected areas lacks behind international standards. Currently it is not considered as a separate land use or planning objective, and modern recreational benefits of provision for health and wellbeing and the high esteem of outdoor recreation by the general population are ignored. Improvements would require a professional implementation process which should consider: – Area specific databases on outdoor recreation activities, including their spatial distribution; – A dedicated training and education in outdoor recreation planning and management (instead of it being an additional task for ecologically trained managers); – A strengthening of outdoor recreation research; – The mandated development and implementation of outdoor recreation related guidelines and monitoring plans; and – The development of specific frameworks sensitive to various ecological conditions (e.g. water based landscapes or forests).

Marie Stenseke; Anderas S. Hansen

2014-01-01T23:59:59.000Z

159

Indoor-outdoor air leakage of apartments and commercial buildings.  

NLE Websites -- All DOE Office Websites (Extended Search)

Indoor-outdoor air leakage of apartments and commercial buildings. Indoor-outdoor air leakage of apartments and commercial buildings. Title Indoor-outdoor air leakage of apartments and commercial buildings. Publication Type Report Year of Publication 2006 Authors Price, Phillip N., Arman Shehabi, Wanyu R. Chan, and Ashok J. Gadgil Publisher Lawrence Berkeley National Laboratory Abstract We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

160

Outdoor airflow into HVAC systems: An evaluation of measurement  

NLE Websites -- All DOE Office Websites (Extended Search)

Outdoor airflow into HVAC systems: An evaluation of measurement Outdoor airflow into HVAC systems: An evaluation of measurement technologies Title Outdoor airflow into HVAC systems: An evaluation of measurement technologies Publication Type Report LBNL Report Number LBNL-53834 Year of Publication 2003 Authors Fisk, William J., David Faulkner, Douglas P. Sullivan, and William W. Delp Abstract During the last few years, new technologies have been introduced for measuring the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for controlled evaluation of these measurement technologies. The results of tests of three measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The test results indicate that one measurement technology can measure OA flow rates with errors of 20% or less without a field-based calibration, as long as the OA velocities are sufficient to provide an accurately measurable pressure signal. The test results for a second measurement technology are similar; however, a difficult field-based calibration relating the OA flow rate with the pressure signal would be required to reduce errors below approximately 30%. The errors in OA flow rates measured with the third measurement technology, that uses six electronic airspeed sensors downstream of the OA inlet louver, exceeded 100%; however, these errors could be substantially reduced through a difficult field based calibration. The effects of wind on the accuracy of these measurement technologies still needs to be evaluated

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Minimizing Variation in Outdoor CPV Power Ratings (Presentation)  

SciTech Connect

Module data from NREL's CPV test bed is used to examine methods for calculating outdoor CPV power ratings. IEC 62670 and ASTM E2527 are used as a starting point for determining a module power rating on a monthly basis. Monthly power ratings vary by more than desired using existing methods. The presentation examines modifications to existing methods as well as spectral corrections to reduce variation in monthly module power ratings.

Muller, M.

2011-02-01T23:59:59.000Z

162

Estimated environmental radionuclide transfer and deposition into outdoor swimming pools  

Science Journals Connector (OSTI)

Abstract In 2011, a large radioactive discharge occurred at the Fukushima Daiichi nuclear power plant. This plant is located within a climatically temperate region where outdoor swimming pools are popular. Although it is relatively easy to decontaminate pools by refilling them with fresh water, it is difficult to maintain safe conditions given highly contaminated diurnal dust falls from the surrounding contaminated ground. Our objectives in this paper were to conduct daily radioactivity measurements, to determine the quantity of radioactive contaminants from the surrounding environment that invade outdoor pools, and to investigate the efficacy of traditional pool cleaners in removing radioactive contaminants. The depositions in the paper filterable particulates ranged from 0 to 62,5 Bq/m2/day, with the highest levels found in the southern Tohoku District containing Fukushima Prefecture and in the Kanto District containing Tokyo Metro. They were approximately correlated with the ground contamination. Traditional pool cleaners eliminated 99% of contaminants at the bottom of the pool, reducing the concentration to 41 Bq/m2 after cleaning. Authors recommended the deposition or the blown radionuclides into outdoor swimming pools must be considered into pool regulations when the environments exactly polluted with radionuclides.

Kazumi Tagami; Izumi Nagata; Keisuke Sueki

2014-01-01T23:59:59.000Z

163

Georgia Underground Storage Tank Act (Georgia) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Underground Storage Tank Act (Georgia) Underground Storage Tank Act (Georgia) Georgia Underground Storage Tank Act (Georgia) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State Georgia Program Type Environmental Regulations Siting and Permitting Provider Georgia Department of Natural Resources The Georgia Underground Storage Act (GUST) provides a comprehensive program to prevent, detect, and correct releases from underground storage tanks

164

DOE - Office of Legacy Management -- Hoe Creek Underground Coal  

NLE Websites -- All DOE Office Websites (Extended Search)

Hoe Creek Underground Coal Hoe Creek Underground Coal Gasification Site - 045 FUSRAP Considered Sites Site: Hoe Creek Underground Coal Gasification Site (045) Designated Name: Alternate Name: Location: Evaluation Year: Site Operations: Site Disposition: Radioactive Materials Handled: Primary Radioactive Materials Handled: Radiological Survey(s): Site Status: The Hoe Creek Underground Gasification site occupies 80 acres of land located in Campbell County, Wyoming. The site was used to investigate the process and environmental parameters of underground coal gasification technologies in the 1970s. The Department of Energy¿s (DOE) current mission is limited to completing environmental remediation activities at the site. This property is owned by the Bureau of Land Management (BLM),

165

Underground Storage Tank Regulations for the Certification of Persons Who  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Underground Storage Tank Regulations for the Certification of Underground Storage Tank Regulations for the Certification of Persons Who Install, Alter, and Remove Underground Storage Tanks (Mississippi) Underground Storage Tank Regulations for the Certification of Persons Who Install, Alter, and Remove Underground Storage Tanks (Mississippi) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells

166

LED Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

LED Lighting Basics LED Lighting Basics LED Lighting Basics August 16, 2013 - 10:07am Addthis Light-emitting diodes (LEDs) are light sources that differ from more traditional sources of light in that they are semiconductor devices that produce light when an electrical current is applied. Applying electrical current causes electrons to flow from the positive side of a diode to the negative side. Then, at the positive/negative junction of the diode, the electrons slow down to orbit at a lower energy level. The electrons emit the excess energy as photons of light. LEDs are often used as small indicator lights on various electronic devices. Because of their long life, durability, and efficiency, LEDs are becoming more common in residential, commercial, and outdoor area lighting

167

Exploring relationships between outdoor air particulate-associated  

NLE Websites -- All DOE Office Websites (Extended Search)

Exploring relationships between outdoor air particulate-associated Exploring relationships between outdoor air particulate-associated polycyclic aromatic hydrocarbon and PM2.5: A case study of benzo(a)pyrene in California metropolitan regions Title Exploring relationships between outdoor air particulate-associated polycyclic aromatic hydrocarbon and PM2.5: A case study of benzo(a)pyrene in California metropolitan regions Publication Type Journal Article LBNL Report Number LBNL-514E Year of Publication 2008 Authors Lobscheid, Agnes B., Thomas E. McKone, and D. A. Valleroc Journal Atmospheric Environment Volume 41 Start Page Chapter Pagination 5659-5672 Abstract Polycyclic aromatic hydrocarbons (PAHs) and particulate matter (PM) are co-pollutants emitted as by-products of combustion processes. Convincing evidence exists for PAHs as a primary toxic component of fine PM (PM2.5). Because PM2.5 is listed by the US EPA as a "Criteria Pollutant," it is monitored regularly at sites nationwide. In contrast, very limited data is available on measured ambient air concentrations of PAHs. However, between 1999-2001, ambient air concentrations of PM2.5 and benzo(a)pyrene (BaP) are available for California locations. We use multivariate linear regression models (MLRMs) to predict ambient air levels of BaP in four air basins based on reported PM2.5 concentrations and spatial, temporal and meteorological variables as variates. We obtain an R2 ranging from 0.57-0.72 among these basins. Significant variables (p<0.05) include the average daily PM2.5 concentration, wind speed, temperature and relative humidity, and the coastal distance as well as season, and holiday or weekend. Combining the data from all sites and using only these variables to estimate ambient BaP levels, we obtain an R2 of 0.55. These R2-values, combined with analysis of the residual error and cross validation using the PRESS-statistic, demonstrate the potential of our method to estimate reported outdoor air PAH exposure levels in metropolitan regions. These MLRMs provide a first step towards relating outdoor ambient PM2.5 and PAH concentrations for epidemiological studies when PAH measurements are unavailable, or limited in spatial coverage, based on publicly available meteorological and PM2.5 data

168

Outdoor testing of advanced optical materials for solar thermal electric applications  

SciTech Connect

The development of low-cost, durable advanced optical materials is an important element in making solar energy viable for electricity production. It is important to determine the expected lifetime of candidate reflector materials in real-world service conditions. The demonstration of the optical durability of such materials in outdoor environments is critical to the successful commercialization of solar thermal electric technologies. For many years optical performance data have been collected and analyzed by the National Renewable Energy Laboratory (NREL) for candidate reflector materials subjected to simulated outdoor exposure conditions. Much of this testing is accelerated in order to predict service durability. Some outdoor testing has occurred but not in a systematic manner. To date, simulated/accelerated testing has been limited correlation with actual outdoor exposure testing. Such a correlation is desirable to provide confidence in lifetime predictions based upon accelerated weathering methods. To obtain outdoor exposure data for realistic environments and to establish a data base for correlating simulated/accelerated outdoor exposure data with actual outdoor exposure data, the development of an expanded outdoor testing program has recently been initiated by NREL. Several outdoor test sites will be selected based on the solar climate, potential for solar energy utilization by industry, and cost of installation. Test results are site dependent because exposure conditions vary with geographical location. The importance of this program to optical materials development is outlined, and the process used to determine and establish the outdoor test sites is described. Candidate material identification and selection is also discussed. 10 refs.

Wendelin, T.J.; Jorgensen, G.; Goggin, R.M.

1992-05-01T23:59:59.000Z

169

Underground Natural Gas Working Storage Capacity - Methodology  

Gasoline and Diesel Fuel Update (EIA)

Summary Prices Exploration & Reserves Production Imports/Exports Pipelines Storage Consumption All Natural Gas Data Reports Analysis & Projections Most Requested Consumption Exploration & Reserves Imports/Exports & Pipelines Prices Production Projections Storage All Reports ‹ See All Natural Gas Reports Underground Natural Gas Working Storage Capacity With Data for November 2012 | Release Date: July 24, 2013 | Next Release Date: Spring 2014 Previous Issues Year: 2013 2012 2011 2010 2009 2008 2007 2006 Go Methodology Demonstrated Peak Working Gas Capacity Estimates: Estimates are based on aggregation of the noncoincident peak levels of working gas inventories at individual storage fields as reported monthly over a 60-month period ending in November 2012 on Form EIA-191, "Monthly Natural Gas Underground Storage

170

The Sanford underground research facility at Homestake  

SciTech Connect

The former Homestake gold mine in Lead, South Dakota is being transformed into a dedicated laboratory to pursue underground research in rare-process physics, as well as offering research opportunities in other disciplines such as biology, geology and engineering. A key component of the Sanford Underground Research Facility (SURF) is the Davis Campus, which is in operation at the 4850-foot level (4300 m.w.e) and currently hosts three projects: the LUX dark matter experiment, the MAJORANA DEMONSTRATOR neutrinoless double-beta decay experiment and the CUBED low-background counter. Plans for possible future experiments at SURF are well underway and include long baseline neutrino oscillation experiments, future dark matter experiments as well as nuclear astrophysics accelerators. Facility upgrades to accommodate some of these future projects have already started. SURF is a dedicated facility with significant expansion capability.

Heise, J. [Sanford Underground Research Facility, 630 East Summit Street, Lead, SD 57754 (United States)

2014-06-24T23:59:59.000Z

171

Central Georgia El Member Corp | Open Energy Information  

Open Energy Info (EERE)

Georgia El Member Corp Georgia El Member Corp Place Georgia Utility Id 3248 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Outdoor Lighting Overhead Wiring HPS 100 W Existing Pole Lighting Outdoor Lighting Overhead Wiring HPS 100 W No Exisitng Pole Lighting Outdoor Lighting Overhead Wiring HPS 250 W Existing Pole Lighting Outdoor Lighting Overhead Wiring HPS 250 W No Existing Pole Lighting Outdoor Lighting Underground Wiring 100 W Lighting Outdoor Lighting Underground Wiring 250 W Lighting

172

Orcas Power & Light Coop | Open Energy Information  

Open Energy Info (EERE)

Orcas Power & Light Coop Orcas Power & Light Coop Jump to: navigation, search Name Orcas Power & Light Coop Place Washington Utility Id 14170 Utility Location Yes Ownership C NERC Location WECC NERC WECC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png TARIFF CS-12 COMMERCIAL SERVICE Industrial TARIFF LR-12 LINE RETENTION Commercial TARIFF M-12 MARINA SERVICE Commercial TARIFF NM-12 UNMETERED SERVICE Commercial TARIFF P-12 PUMP SERVICE Industrial TARIFF POL-12 PRIVATE OUTDOOR LIGHTING 100 Watts Lighting TARIFF POL-12 PRIVATE OUTDOOR LIGHTING 200 Watts Lighting

173

Outdoor unit construction for an electric heat pump  

DOE Patents (OSTI)

The outdoor unit for an electric heat pump is provided with an upper portion containing propeller fan means for drawing air through the lower portion containing refrigerant coil means in the form of four discrete coils connected together in a subassembly forming a W shape, the unit being provided with four adjustable legs which are retracted in shipment, and are adjusted on site to elevate the unit to a particular height suitable for the particular location in which the unit is installed. 4 figs.

Draper, R.; Lackey, R.S.

1984-09-11T23:59:59.000Z

174

Outdoor polymeric insulators long-term exposed to HVDC  

SciTech Connect

Field experience from outdoor polymeric insulators exposed to HVDC under natural contamination conditions is presented. This paper summarizes the peak leakage current statistics, the hydrophobicity and the surface material conditions studied by electron spectroscopy for chemical analysis (ESCA) and attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The results show a strong interrelation between the surface conditions and the performance with respect to leakage currents. Moreover, the results show that the surface conditions and the performance of the insulators exposed to HVDC are rather similar to those of the insulators exposed to HVAC.

Soerqvist, T.; Vlastos, A.E. [Chalmers Univ. of Technology, Gothenburg (Sweden)] [Chalmers Univ. of Technology, Gothenburg (Sweden)

1997-04-01T23:59:59.000Z

175

OUTDOOR RECREATION USE AND VALUE: SNAKE RIVER BASIN OF CENTRAL IDAHO  

E-Print Network (OSTI)

OUTDOOR RECREATION USE AND VALUE: SNAKE RIVER BASIN OF CENTRAL IDAHO John R. McKean Agricultural . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Recreation Demand Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Recreation Demand Survey

O'Laughlin, Jay

176

Assessment of motivation and interest in outdoor recreation activities facilitated by a campus recreation center.  

E-Print Network (OSTI)

?? This study assessed the motivation and interest in outdoor recreation activities as facilitated by a campus recreation center. The sample consisted of college students… (more)

Rayburn, Pamela J.

2014-01-01T23:59:59.000Z

177

Dynamic predictive clothing insulation models based on outdoor air and indoor operative temperatures  

E-Print Network (OSTI)

predictive clothing insulation models based on outdoor airrange of the clothing insulation calculated for eachbuilding). Figure 8 Clothing insulation versus dress code [

Schiavon, Stefano; Lee, Kwang Ho

2012-01-01T23:59:59.000Z

178

E-Print Network 3.0 - asthma outdoor air Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Sample search results for: asthma outdoor air Page: << < 1 2 3 4 5 > >> 1 About the Air Pollution and Respiratory Health Program The Air Pollution and Respiratory Health...

179

Arkansas Underground Injection Control Code (Arkansas) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Arkansas Underground Injection Control Code (Arkansas) Arkansas Underground Injection Control Code (Arkansas) Arkansas Underground Injection Control Code (Arkansas) < Back Eligibility Commercial Construction Industrial Utility Program Info State Arkansas Program Type Environmental Regulations Siting and Permitting Provider Department of Environmental Quality The Arkansas Underground Injection Control Code (UIC code) is adopted pursuant to the provisions of the Arkansas Water and Air Pollution Control Act (Arkansas Code Annotated 8-5-11). It is the purpose of this UIC Code to adopt underground injection control (UIC) regulations necessary to qualify the State of Arkansas to retain authorization for its Underground Injection Control Program pursuant to the Safe Drinking Water Act of 1974, as amended; 42 USC 300f et seq. In order

180

Wells, Borings, and Underground Uses (Minnesota) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Wells, Borings, and Underground Uses (Minnesota) Wells, Borings, and Underground Uses (Minnesota) Wells, Borings, and Underground Uses (Minnesota) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State Minnesota Program Type Siting and Permitting This section regulates wells, borings, and underground storage with regards to protecting groundwater resources. The Commissioner of the Department of Health has jurisdiction, and can grant permits for proposed activities,

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Utah Division of Environmental Response and Remediation Underground...  

Open Energy Info (EERE)

Division of Environmental Response and Remediation Underground Storage Tank Branch Webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Utah...

182

Idaho Underground Injection Control Program Webpage | Open Energy...  

Open Energy Info (EERE)

Program Webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Idaho Underground Injection Control Program Webpage Author Idaho Department of...

183

,"Underground Natural Gas Storage - Storage Fields Other than...  

U.S. Energy Information Administration (EIA) Indexed Site

Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","Underground Natural Gas Storage - Storage Fields Other than Salt Caverns",8,"Monthly","102014","115...

184

All of Hanford's underground waste tanks generate hydrogen gas...  

NLE Websites -- All DOE Office Websites (Extended Search)

of Hanford's underground waste tanks generate hydrogen gas to some degree since the radioactivity in the waste releases hydrogen from basic nuclear reactions. The routine release...

185

Title 18 Alaska Administrative Code Chapter 78 Underground Storage...  

Open Energy Info (EERE)

Underground Storage Tanks Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- RegulationRegulation: Title 18 Alaska Administrative Code Chapter 78...

186

Hawaii Department of Health Underground Storage Tank Webpage...  

Open Energy Info (EERE)

Abstract This webpage provides information on the regulation of underground storage tanks. Author State of Hawaii Department of Health Published State of Hawaii, Date Not...

187

Hawaii Underground Injection Control Program Webpage | Open Energy...  

Open Energy Info (EERE)

Program Webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Hawaii Underground Injection Control Program Webpage Author State of Hawaii...

188

NNSA Commemorates the 20th Anniversary of the Last Underground...  

National Nuclear Security Administration (NNSA)

Commemorates the 20th Anniversary of the Last Underground Nuclear Test | National Nuclear Security Administration People Mission Managing the Stockpile Preventing Proliferation...

189

,"New York Underground Natural Gas Storage - All Operators"  

U.S. Energy Information Administration (EIA) Indexed Site

Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","New York Underground Natural Gas Storage - All Operators",3,"Annual",2013,"6301967" ,"Release...

190

Underground coal gasification : overview of an economic and environmental evaluation.  

E-Print Network (OSTI)

??This paper examines an overview of the economic and environmental aspects of Underground Coal Gasification (UCG) as a viable option to the above ground Surface… (more)

Kitaka, Richard Herbertson

2012-01-01T23:59:59.000Z

191

EPA - Ground Water Discharges (EPA's Underground Injection Control...  

Open Energy Info (EERE)

EPA - Ground Water Discharges (EPA's Underground Injection Control Program) webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: EPA - Ground Water...

192

Underground Storage Tanks (New Jersey) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Underground Storage Tanks (New Jersey) Underground Storage Tanks (New Jersey) Underground Storage Tanks (New Jersey) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State New Jersey Program Type Safety and Operational Guidelines This chapter constitutes rules for all underground storage tank facilities- including registration, reporting, permitting, certification, financial responsibility and to protect human health and the environment

193

Contributions of artificial lighting sources on light pollution in Hong Kong measured through a night sky brightness monitoring network  

E-Print Network (OSTI)

Light pollution is a form of environmental degradation in which excessive artificial outdoor lighting, such as street lamps, neon signs, and illuminated signboards, affects the natural environment and the ecosystem. Poorly designed outdoor lighting not only wastes energy, money, and valuable Earth resources, but also robs us of our beautiful night sky. Effects of light pollution on the night sky can be evaluated by the skyglow caused by these artificial lighting sources, through measurements of the night sky brightness (NSB). The Hong Kong Night Sky Brightness Monitoring Network (NSN) was established to monitor in detail the conditions of light pollution in Hong Kong. Monitoring stations were set up throughout the city covering a wide range of urban and rural settings to continuously measure the variations of the NSB. Over 4.6 million night sky measurements were collected from 18 distinct locations between May 2010 and March 2013. This huge dataset, over two thousand times larger than our previous survey, for...

Pun, Chun Shing Jason; Leung, Wai Yan; Wong, Chung Fai

2014-01-01T23:59:59.000Z

194

Outdoor recreation – A necessity or a luxury? Estimation of Engel curves for Sweden  

Science Journals Connector (OSTI)

Abstract Income constitutes one important constraint for the degree of participation in outdoor recreation. The effect of this constraint can be measured by the income elasticity of outdoor recreation demand, which is of policy interest when the distribution of recreation opportunities across socioeconomic groups is a concern. This study investigated income elasticity of expenditures for three types of outdoor recreation in Sweden, at the individual level: outdoor recreation as an aggregated composite good, outdoor recreation close to home (less than 100 km away from the permanent residence), and hunting. The findings indicated that outdoor recreation as a composite is a luxury good with elasticity in excess of unity (i.e. a relative increase in income will lead to a greater relative increase in demand). The elasticities of the specific activities were found to be lower. Outdoor recreation close to home was characterized as a necessity with elasticity less than unity (i.e. a relative increase in income will lead to a smaller relative increase in demand). The results further suggested that an increase in income could lead to either a decrease or an increase in the demand for hunting, indicating that hunting might be an inferior good or possibly a necessity. Management implications Based on data from national surveys in Sweden, this paper explores the relationship between income and demand for different types of outdoor recreation activities. The analysis reveals that: • The total demand for outdoor recreation opportunities can be expected to increase with increasing income levels in society. An increase in total demand does, however, not imply that demand for all types of outdoor recreation will increase simultaneously. • The relationship between income and outdoor recreation demand differs among various types of recreation activities. Outdoor recreation close to home and hunting provided two examples of such diverging patterns in this paper. This, in turn, leads to different policy implications. • Policy measures should, therefore, be adapted to the specific type of outdoor recreation under consideration. • Managers need to be aware of the underlying factors affecting demand, such as socioeconomic characteristics, substitutability, motivations and different types of constraints. • Future analysis should consider also the following factors potentially affecting outdoor recreation demand: - The distinction between recreation enjoyed during overnight trips (i.e. tourism related), as opposed to day based recreation activities where income may be less important. - The time available for outdoor recreation and the family situation. - Recreational activities must be regarded within the regulatory national framework. For example hunting in Sweden is guided by bag limits, reduced mobility because of limited access to specific hunting grounds, and specific national management of hunting opportunities.

Mattias Boman; Peter Fredman; Linda Lundmark; Göran Ericsson

2013-01-01T23:59:59.000Z

195

Key tests set for underground coal gasification  

SciTech Connect

Underground coal gasification (UCG) is about to undergo some tests. The tests will be conducted by Lawrence Livermore National Laboratory (LLNL) in a coal seam owned by Washington Irrigation and Development Co. A much-improved UCG system has been developed by Stephens and his associates at LLNL - the controlled retracting injection point (CRIP) method. Pritchard Corp., Kansas City, has done some conceptual process design and has further studied the feasibility of using the raw gas from a UCG burn as a feedstock for methanol synthesis and/or MTG gasoline. Each method was described. (DP)

Haggin, J.

1983-07-18T23:59:59.000Z

196

Peak Underground Working Natural Gas Storage Capacity  

Gasoline and Diesel Fuel Update (EIA)

Methodology Methodology Methodology Demonstrated Peak Working Gas Capacity Estimates: Estimates are based on aggregation of the noncoincident peak levels of working gas inventories at individual storage fields as reported monthly over a 60-month period ending in April 2010 on Form EIA-191M, "Monthly Natural Gas Underground Storage Report." The months of measurement for the peak storage volumes by facilities may differ; i.e., the months do not necessarily coincide. As such, the noncoincident peak for any region is at least as big as any monthly volume in the historical record. Data from Form EIA-191M, "Monthly Natural Gas Underground Storage Report," are collected from storage operators on a field-level basis. Operators can report field-level data either on a per reservoir basis or on an aggregated reservoir basis. It is possible that if all operators reported on a per reservoir basis that the demonstrated peak working gas capacity would be larger. Additionally, these data reflect inventory levels as of the last day of the report month, and a facility may have reached a higher inventory on a different day of the report month, which would not be recorded on Form EIA-191M.

197

Underground coal gasification using oxygen and steam  

SciTech Connect

In this paper, through model experiment of the underground coal gasification, the effects of pure oxygen gasification, oxygen-steam gasification, and moving-point gasification methods on the underground gasification process and gas quality were studied. Experiments showed that H{sub 2} and CO volume fraction in product gas during the pure oxygen gasification was 23.63-30.24% and 35.22-46.32%, respectively, with the gas heating value exceeding 11.00 MJ/m{sup 3}; under the oxygen-steam gasification, when the steam/oxygen ratio stood at 2: 1, gas compositions remained virtually stable and CO + H{sub 2} was basically between 61.66 and 71.29%. Moving-point gasification could effectively improve the changes in the cavity in the coal seams or the effects of roof inbreak on gas quality; the ratio of gas flowing quantity to oxygen supplying quantity was between 3.1:1 and 3.5:1 and took on the linear changes; on the basis of the test data, the reasons for gas quality changes under different gasification conditions were analyzed.

Yang, L.H.; Zhang, X.; Liu, S. [China University of Mining & Technology, Xuzhou (China)

2009-07-01T23:59:59.000Z

198

Effects of network-average magnitude bias on yield estimates for underground nuclear explosions  

Science Journals Connector (OSTI)

......yield estimates for underground nuclear explosions R. A. Clark Department...ISC, of presumed underground nuclear explosions in Kazakhstan...on estimates for underground nuclear explosions 553 explosions...utilizing a more extensive dataset, including more sources and......

R. A. Clark

1983-11-01T23:59:59.000Z

199

Seasonal thermal signatures of heat transfer by water exchange in an underground vault  

Science Journals Connector (OSTI)

......also to the long-term temperature...underground waste storage and contaminant...underground nuclear waste storage sites is...2000), the long-term impact and...Concerning the long-term temperature...underground waste storage, underlying......

Frédéric Perrier; Pierre Morat; Toshio Yoshino; Osam Sano; Hisashi Utada; Olivier Gensane; Jean-Louis Le Mouël

2004-07-01T23:59:59.000Z

200

Permanent Closure of the TAN-664 Underground Storage Tank  

SciTech Connect

This closure package documents the site assessment and permanent closure of the TAN-664 gasoline underground storage tank in accordance with the regulatory requirements established in 40 CFR 280.71, 'Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.'

Bradley K. Griffith

2011-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Overall requirements for an advanced underground coal extraction system  

SciTech Connect

This report presents overall requirements on underground mining systems suitable for coal seams exploitable in the year 2000, with particular relevance to the resources of Central Appalachia. These requirements may be summarized as follows: (1) Production Cost: demonstrate a return on incremental investment of 1.5 to 2.5 times the value required by a low-risk capital project. (2) Miner Safety: achieve at least a 50% reduction in deaths and disabling injuries per million man-hours. (3) Miner Health: meet the intent of all applicable regulations, with particular attention to coal dust, carcinogens, and mutagens; and with continued emphasis on acceptable levels of noise and vibration, lighting, humidity and temperature, and adequate work space. (4) Environmental Impact: maintain the value of mined and adjacent lands at the pre-mining value following reclamation; mitigation of off-site impacts should not cost more than the procedures used in contemporary mining. (5) Coal Conservation: the recovery of coal from the seam being mined should be at least as good as the best available contemporary technology operating in comparable conditions. No significant trade-offs between production cost and other performance indices were found.

Goldsmith, M.; Lavin, M.L.

1980-10-15T23:59:59.000Z

202

Thermosyphon coil arrangement for heat pump outdoor unit  

DOE Patents (OSTI)

For a heat pump, the outdoor unit is provided with a coil and a refrigerant flow arrangement there for which is such that in the heating mode of operation of the heat pump they operate in a thermosyphon fashion. The coil has a feed portion and an exit portion leading to a separator drum from which liquid refrigerant is returned through downcomer line for recirculation to the feed portion. The coil is tilted upwardly from entry to exit by the angle alpha to enhance the clearance of the two phases of refrigerant from each other in the heating mode of operation. There is no thermosyphon function in the cooling mode of operation. 9 figs.

Draper, R.

1984-05-22T23:59:59.000Z

203

Alabama Underground Storage Tank And Wellhead Protection Act (Alabama) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alabama Underground Storage Tank And Wellhead Protection Act Alabama Underground Storage Tank And Wellhead Protection Act (Alabama) Alabama Underground Storage Tank And Wellhead Protection Act (Alabama) < Back Eligibility Commercial Construction Industrial Municipal/Public Utility Savings Category Buying & Making Electricity Water Home Weatherization Program Info State Alabama Program Type Environmental Regulations The department, acting through the commission, is authorized to promulgate rules and regulations governing underground storage tanks and is authorized to seek the approval of the United States Environmental Protection Agency to operate the state underground storage tank program in lieu of the federal program. In addition to specific authorities provided by this chapter, the department is authorized, acting through the commission, to

204

The Strip and Underground Mine Reclamation Act (Montana) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Strip and Underground Mine Reclamation Act (Montana) The Strip and Underground Mine Reclamation Act (Montana) The Strip and Underground Mine Reclamation Act (Montana) < Back Eligibility Utility Investor-Owned Utility Industrial Construction Municipal/Public Utility Installer/Contractor Rural Electric Cooperative Program Info State Montana Program Type Siting and Permitting Provider Montana Department of Environmental Quality The policy of the state is to provide adequate remedies to protect the environmental life support system from degradation and to prevent unreasonable depletion and degradation of natural resources from strip and underground mining. This Act imposes permitting and operating restrictions on strip and underground mining activities for coal and uranium, and authorizes the Department of Environmental Quality to administer a

205

Indoor-Outdoor Concentrations and Correlations of PM10-Associated Mutagenic Activity in Nonsmokers' and Asthmatics' Homes  

Science Journals Connector (OSTI)

Indoor-Outdoor Concentrations and Correlations of PM10-Associated Mutagenic Activity in Nonsmokers' and Asthmatics' Homes ...

Norman Y. Kado; Steven D. Colome; Michael T. Kleinman; Dennis P. H. Hsieh; Peter. Jaques

1994-06-01T23:59:59.000Z

206

Head of EM Visits Waste Isolation Pilot Plant for First Underground...  

Office of Environmental Management (EM)

Head of EM Visits Waste Isolation Pilot Plant for First Underground Tour Since February Incidents Head of EM Visits Waste Isolation Pilot Plant for First Underground Tour Since...

207

E-Print Network 3.0 - advanced underground gas Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

Mulder1 Summary: where all current underground activities take place except for oil and gas extraction and mining... with reluctant public perception still hamper such underground...

208

The Remote Video Monitoring System Design and Development for Underground Substation Construction Process  

Science Journals Connector (OSTI)

From the current situation of underground substation construction in China, we design and development ... image enhancement technology, the construction of underground substation can be clearly and accurately tra...

Siguo Zheng; Yugan You; Fanguang Li; Gang Liu

2012-01-01T23:59:59.000Z

209

E-Print Network 3.0 - american underground science Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

underground science Search Powered by Explorit Topic List Advanced Search Sample search results for: american underground science Page: << < 1 2 3 4 5 > >> 1 Studying the Universe...

210

Peak Underground Working Natural Gas Storage Capacity  

Gasoline and Diesel Fuel Update (EIA)

Definitions Definitions Definitions Since 2006, EIA has reported two measures of aggregate capacity, one based on demonstrated peak working gas storage, the other on working gas design capacity. Demonstrated Peak Working Gas Capacity: This measure sums the highest storage inventory level of working gas observed in each facility over the 5-year range from May 2005 to April 2010, as reported by the operator on the Form EIA-191M, "Monthly Underground Gas Storage Report." This data-driven estimate reflects actual operator experience. However, the timing for peaks for different fields need not coincide. Also, actual available maximum capacity for any storage facility may exceed its reported maximum storage level over the last 5 years, and is virtually certain to do so in the case of newly commissioned or expanded facilities. Therefore, this measure provides a conservative indicator of capacity that may understate the amount that can actually be stored.

211

Surface effects of underground nuclear explosions  

SciTech Connect

The effects of nuclear explosions have been observed and studied since the first nuclear test (code named Trinity) on July 16, 1945. Since that first detonation, 1,053 nuclear tests have been conducted by the US, most of which were sited underground at the Nevada Test Site (NTS). The effects of underground nuclear explosions (UNEs) on their surroundings have long been the object of much interest and study, especially for containment, engineering, and treaty verification purposes. One aspect of these explosion-induced phenomena is the disruption or alteration of the near-surface environment, also known as surface effects. This report was prepared at the request of the Los Alamos National Laboratory (LANL), to bring together, correlate, and preserve information and techniques used in the recognition and documentation of surface effects of UNEs. This report has several main sections, including pertinent background information (Section 2.0), descriptions of the different types of surface effects (Section 3.0), discussion of their application and limitations (Section 4.0), an extensive bibliography and glossary (Section 6.0 and Appendix A), and procedures used to document geologic surface effects at the NTS (Appendix C). Because a majority of US surface-effects experience is from the NTS, an overview of pertinent NTS-specific information also is provided in Appendix B. It is not within the scope of this report to explore new relationships among test parameters, physiographic setting, and the types or degree of manifestation of surface effects, but rather to compile, summarize, and capture surface-effects observations and interpretations, as well as documentation procedures and the rationale behind them.

Allen, B.M.; Drellack, S.L. Jr.; Townsend, M.J.

1997-06-01T23:59:59.000Z

212

System Architecture Directions for a Software-Defined Lighting Infrastructure  

E-Print Network (OSTI)

spectrum of an outdoor environment and a typical fluorescent tube-lit office space. Indoor spectrum to incandescent and fluorescent lights. Unfortunately, the remarkable march of semiconductor technology a renaissance. The staple of illumi- nation for one and a half centuries, the incandescent bulb, is being phased

Dutta, Prabal

213

Text-Alternative Version of TAP Webinar: High Performance Outdoor Lighting Accelerator  

Energy.gov (U.S. Department of Energy (DOE))

Nebiat Solomon ? We are going to give other attendees a few minutes to get on, and then we’ll be ready to start.  Just so you know, if you have questions along the way, just type them into the...

214

DOE Announces Webinars on Successful Project Financing Mechanisms, the High Performance Outdoor Lighting Accelerator, and More  

Office of Energy Efficiency and Renewable Energy (EERE)

EERE offers webinars to the public on a range of subjects, from adopting the latest energy efficiency and renewable energy technologies, to training for the clean energy workforce. Webinars are free; however, advanced registration is typically required. You can also watch archived webinars and browse previously aired videos, slides, and transcripts.

215

Salt River Electric Coop Corp | Open Energy Information  

Open Energy Info (EERE)

Salt River Electric Coop Corp Salt River Electric Coop Corp Place Kentucky Utility Id 16587 Utility Location Yes Ownership C NERC Location RFC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 (Decorative Underground) HPS 48 kWh Outdoor Lighting Lighting 100 Watt HPS 48 kWh Outdoor Lighting Lighting 175 Watt MV 75 kWh Outdoor Lighting Lighting 175 Wattage (Underground) MV 75 kWh (without pole) Lighting 250 Watt HPS 104 kWh Outdoor Lighting Lighting 400 Watt HPS 165 kWh Outdoor Lighting Lighting Cogeneration and small power production power purchase rate schedule less

216

Learning Visual Feature Descriptors for Dynamic Lighting Conditions Nicholas Carlevaris-Bianco and Ryan M. Eustice  

E-Print Network (OSTI)

Learning Visual Feature Descriptors for Dynamic Lighting Conditions Nicholas Carlevaris, the success or failure of feature-based image registration is largely determined by changes in lighting conditions are presented for a challenging indoor-outdoor dataset spanning 27 mapping sessions over a period

Eustice, Ryan

217

Underground Storage Tank Act (West Virginia) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Act (West Virginia) Act (West Virginia) Underground Storage Tank Act (West Virginia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State West Virginia Program Type Siting and Permitting Provider Department of Environmental Protection New underground storage tank construction standards must include at least the following requirements: (1) That an underground storage tank will prevent releases of regulated substances stored therein, which may occur as

218

Fire Simulation, Evacuation Analysis and Proposal of Fire Protection Systems Inside an Underground Cavern  

E-Print Network (OSTI)

Fire Simulation, Evacuation Analysis and Proposal of Fire Protection Systems Inside an Underground Cavern

Stella, Carlo

219

A study of the feasibility of construction of underground storage structures in soft soil  

E-Print Network (OSTI)

Introduction Page 44 46 Construction Procedure for an Underground Storage Structure for Liquid Materials Construction Procedure for an Underground Storage Structure for Solid Materials 46 48 Geotechnical Considerations in the Construction Procedure... Introduction Page 44 46 Construction Procedure for an Underground Storage Structure for Liquid Materials Construction Procedure for an Underground Storage Structure for Solid Materials 46 48 Geotechnical Considerations in the Construction Procedure...

Rosner, Stephen Anthony

2012-06-07T23:59:59.000Z

220

Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings  

SciTech Connect

We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

Price, P.N.; Shehabi, A.; Chan, R.W.; Gadgil, A.J.

2006-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

The acoustics of the outdoor Shakespeare theater—Rutland, UK  

Science Journals Connector (OSTI)

The outdoor Shakespeare Amphitheatre at Tolethorpe (Rutland UK) is an unusual form of theater in that the actors perform in the open air while the audience is enclosed in a lightweight Teflon fabric auditorium. This unique format produces some unusual acoustic properties and problems. The early reflection patterns from and around the stage are quite different from a normal enclosed proscenium theater. The Teflon walls and roof while effectively acoustically transparent at low and lower midfrequencies become highly reflective at high frequencies. This not only impacts the transmission of sound through the structure but also speech transmission and intelligibility within the auditorium. The hyperbolic curved?roof surfaces and flat parallel walls were found to cause undesirable sound focusing and reflections detrimental to speech intelligibility. The acoustics of the space was investigated by means of both directional and binaural time?domain spectrometry techniques as well as more traditional acoustic measures. The paper presents the results of these measurements and outlines the remedial treatments adopted.

2000-01-01T23:59:59.000Z

222

Outdoor airflow into HVAC systems: An evaluation of measurement technologies  

SciTech Connect

During the last few years, new technologies have been introduced for measuring the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for controlled evaluation of these measurement technologies. The results of tests of three measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The test results indicate that one measurement technology can measure OA flow rates with errors of 20% or less without a field-based calibration, as long as the OA velocities are sufficient to provide an accurately measurable pressure signal. The test results for a second measurement technology are similar; however, a difficult field-based calibration relating the OA flow rate with the pressure signal would be required to reduce errors below approximately 30%. The errors in OA flow rates measured with the third measurement technology, that uses six electronic airspeed sensors downstream of the OA inlet louver, exceeded 100%; however, these errors could be substantially reduced through a difficult field based calibration. The effects of wind on the accuracy of these measurement technologies still needs to be evaluated.

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.; Delp, Woody

2003-09-01T23:59:59.000Z

223

SITEWIDE CATEGORICAL EXCLUSION FOR OUTDOOR TESTS ON MATERIALS AND COMPONENTS, PACIFIC NORTHWEST NATIONAL  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SITEWIDE CATEGORICAL EXCLUSION FOR OUTDOOR TESTS ON SITEWIDE CATEGORICAL EXCLUSION FOR OUTDOOR TESTS ON MATERIALS AND COMPONENTS, PACIFIC NORTHWEST NATIONAL LABORATORY, RICHLAND, WASHINGTON Proposed AetioD: The U.S. Department of Energy (DOE) Pacific Northwest Site Office (PNSO) proposes to conduct outdoor tests and experiments on materials and equipment components under controlled conditions. No source, special nuclear, or byproduct materials would be involved, but encapsulated radioactive sources manufactured to applicable standards or other radiological materials could be used in activities under this categorical exclusion (eX). LoeatioD of Action: The locations would include DOE property at the Pacific Northwest National Laboratory (PNNL) Site and other offsite outdoor locations. Description of the Proposed Action:

224

Ideal balance of work, play makes outdoor enthusiast's James Miller life  

NLE Websites -- All DOE Office Websites (Extended Search)

Ideal balance of work, play makes outdoor enthusiast's life enviable Ideal balance of work, play makes outdoor enthusiast's life enviable Ideal balance of work, play makes outdoor enthusiast's James Miller life enviable Nuclear engineer graduate research assistant gets valueable experience while taking advantage of local outdoor recreational activities. August 2, 2012 James Miller Miller first came to the Laboratory in 2006 as a summer student. His college advisor, a former LANL employee, found him an internship through the student programs office. Miller highly recommends LANL as a place to start a career, "The student programs are very mentor-driven, allowing you to gain phenomenal experience and build a professional network that will set you up for the rest of your life." "I have access to top-level scientists in the world, doing some of the best

225

Inter-group relationships and networks in an outdoor recreation setting  

E-Print Network (OSTI)

This exploratory study examined the information sharing processes between groups of recreationists at two outdoor recreation settings in Sam Houston National Forest. The primary objective of this study was to develop theory that will explain...

Bajc, Vida

2012-06-07T23:59:59.000Z

226

Analysis of a Dedicated Outdoor Air System and Low Temperature Supply Air Conditioning System  

E-Print Network (OSTI)

This paper presents the principles and the characteristics of a dedicated outdoor air system (DOAS) and low temperature supply air system. DOAS is offered based on the demands of indoor air quality and the low temperature supply air system...

Guang, L.; Li, R.

2006-01-01T23:59:59.000Z

227

Bourdieuian Analysis on African Americans’ Under-representation at Parks and Outdoor Recreation  

E-Print Network (OSTI)

This study used Pierre Bourdieu’s theory of practice and analyzed African Americans’ under-representation at parks and in outdoor recreation. It focused on Cedar Hill State Park (CHSP) located in Cedar Hill, Texas and investigated local African...

Lee, KangJae

2013-07-18T23:59:59.000Z

228

Measurement of indoor-outdoor carbonyls at four residential homes in Mexico City metropolitan area  

Science Journals Connector (OSTI)

Formaldehyde, acetaldehyde, acetone, propionaldehyde and butyraldehyde were measured in indoor and outdoor air at three houses and one apartment in the Mexico city metropolitan area (MCMA). Formaldehyde presented the highest concentration in indoor and outdoor air, followed by acetone and acetaldehyde. Indoor carbonyl concentrations were higher than outdoor concentrations at all sampling sites. Indoor exposure factors were estimated for formaldehyde and acetaldehyde, ranging from 202 µg dayâ??1 to 554 µg dayâ??1 for formaldehyde and from 82 µg dayâ??1 to 202 µg dayâ??1 for acetaldehyde. Indoor-outdoor correlations were significant at all sites. However, these correlations were the highest in the Miguel Hidalgo house, which was naturally well ventilated, and where very few activities like cooking, were done. Concerning the Tlalnepantla house, although it was also well ventilated, the correlations were not as high as those observed at the Miguel Hidalgo house, possibly because its inhabitants cook a lot more and throughout the whole day.

Armando P. Baez; Hugo Padilla; Rocio Garcia; Raul Belmont; Ma. Del Carmen Torres

2006-01-01T23:59:59.000Z

229

Architecture for environmental learning : a National Outdoor Leadership School in Baja, Mexico  

E-Print Network (OSTI)

An understanding of people, program, and place establishes a foundation from which to make architectural decisions. The focus of this thesis is to understand the needs of those involved in an outdoor education school in ...

Galyean, Taylor

1994-01-01T23:59:59.000Z

230

Hybrid Self Localization for a Mobile Robotic Platform for Indoor and Outdoor Environments  

E-Print Network (OSTI)

associated with the motion state estimate. As Robotics Research: The DOE University Research Program Platform in Indoor and Outdoor Environments," in Transactions of the American Nuclear Society, Vol. 92, San

Abidi, Mongi A.

231

Net Withdrawals of Natural Gas from Underground Storage (Summary)  

U.S. Energy Information Administration (EIA) Indexed Site

Pipeline and Distribution Use Price Citygate Price Residential Price Commercial Price Industrial Price Vehicle Fuel Price Electric Power Price Proved Reserves as of 12/31 Reserves Adjustments Reserves Revision Increases Reserves Revision Decreases Reserves Sales Reserves Acquisitions Reserves Extensions Reserves New Field Discoveries New Reservoir Discoveries in Old Fields Estimated Production Number of Producing Gas Wells Gross Withdrawals Gross Withdrawals From Gas Wells Gross Withdrawals From Oil Wells Gross Withdrawals From Shale Gas Wells Gross Withdrawals From Coalbed Wells Repressuring Nonhydrocarbon Gases Removed Vented and Flared Marketed Production Natural Gas Processed NGPL Production, Gaseous Equivalent Dry Production Imports By Pipeline LNG Imports Exports Exports By Pipeline LNG Exports Underground Storage Capacity Underground Storage Injections Underground Storage Withdrawals Underground Storage Net Withdrawals LNG Storage Additions LNG Storage Withdrawals LNG Storage Net Withdrawals Total Consumption Lease and Plant Fuel Consumption Lease Fuel Plant Fuel Pipeline & Distribution Use Delivered to Consumers Residential Commercial Industrial Vehicle Fuel Electric Power Period: Monthly Annual

232

EIA - Natural Gas Pipeline Network - Underground Natural Gas Storage  

U.S. Energy Information Administration (EIA) Indexed Site

Storage Storage About U.S. Natural Gas Pipelines - Transporting Natural Gas based on data through 2007/2008 with selected updates Underground Natural Gas Storage Overview | Regional Breakdowns Overview Underground natural gas storage provides pipelines, local distribution companies, producers, and pipeline shippers with an inventory management tool, seasonal supply backup, and access to natural gas needed to avoid imbalances between receipts and deliveries on a pipeline network. There are three principal types of underground storage sites used in the United States today. They are: · depleted natural gas or oil fields (326), · aquifers (43), or · salt caverns (31). In a few cases mine caverns have been used. Most underground storage facilities, 82 percent at the beginning of 2008, were created from reservoirs located in depleted natural gas production fields that were relatively easy to convert to storage service, and that were often close to consumption centers and existing natural gas pipeline systems.

233

Prince George's County Underground Storage Act (Maryland) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Prince George's County Underground Storage Act (Maryland) Prince George&#039;s County Underground Storage Act (Maryland) Prince George's County Underground Storage Act (Maryland) < Back Eligibility Commercial Retail Supplier Tribal Government Program Info State Maryland Program Type Environmental Regulations Provider Maryland Department of the Environment A gas storage company may invoke eminent domain to acquire property in Prince George's County for underground gas storage purposes. The area acquired must lie not less than 800 feet below the surface of a maximum of 12,000 acres of land, and may be owned by a public body. A permit from the Department of the Environment, along with an order from the Public Service Commission, is required prior to the use of eminent domain. The Act contains further information on eminent domain, landowner, and property

234

DOE - Office of Legacy Management -- Los Alamos Underground Med Pipelines -  

NLE Websites -- All DOE Office Websites (Extended Search)

Los Alamos Underground Med Los Alamos Underground Med Pipelines - NM 02 FUSRAP Considered Sites Site: Los Alamos Underground Med Pipelines ( NM.02 ) Eliminated - Remedial action being performed by the Los Alamos Area Office of the DOE Albuquerque Operations Office Designated Name: Not Designated Alternate Name: Los Alamos County Industrial Waste Lines NM.02-1 Location: Los Alamos , New Mexico NM.02-1 Evaluation Year: 1986 NM.02-1 Site Operations: From 1952 to 1965, underground pipelines or industrial waste lines were used at Los Alamos Scientific Laboratory to transport liquid wastes from Technical Areas 1, 3, 48, and 43 to a chemical waste treatment plant (Technical Area 45). NM.02-1 Site Disposition: Eliminated - Remedial action being performed by another DOE office NM.02-1

235

Georgia Underground Gas Storage Act of 1972 (Georgia) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Georgia Underground Gas Storage Act of 1972 (Georgia) Georgia Underground Gas Storage Act of 1972 (Georgia) Georgia Underground Gas Storage Act of 1972 (Georgia) < Back Eligibility Commercial Construction Developer General Public/Consumer Industrial Investor-Owned Utility Municipal/Public Utility Retail Supplier Rural Electric Cooperative Utility Program Info State Georgia Program Type Environmental Regulations Siting and Permitting Provider Georgia Department of Natural Resources The Georgia Underground Gas Storage Act, which permits the building of reserves for withdrawal in periods of peak demand, was created to promote the economic development of the State of Georgia and provide for more economical distribution of gas to the domestic, commercial, and industrial consumers of the State. Any gas utility desiring to utilize or operate an

236

Underground Storage of Natural Gas and Liquefied Petroleum Gas (Nebraska) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Underground Storage of Natural Gas and Liquefied Petroleum Gas Underground Storage of Natural Gas and Liquefied Petroleum Gas (Nebraska) Underground Storage of Natural Gas and Liquefied Petroleum Gas (Nebraska) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State Nebraska Program Type Siting and Permitting Provider Nebraska Oil and Gas Conservation Commission This statute declares underground storage of natural gas and liquefied petroleum gas to be in the public interest if it promotes the conservation

237

Rules and Regulations for Underground Storage Facilities Used for Petroleum  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Rules and Regulations for Underground Storage Facilities Used for Rules and Regulations for Underground Storage Facilities Used for Petroleum Products and Hazardous Materials (Rhode Island) Rules and Regulations for Underground Storage Facilities Used for Petroleum Products and Hazardous Materials (Rhode Island) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Multi-Family Residential Municipal/Public Utility Nonprofit Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State Rhode Island Program Type Environmental Regulations Provider Department of Environmental Management These regulations apply to underground storage facilities for petroleum and

238

Appendix E: Underground Storage Annual Site Environmental Report  

E-Print Network (OSTI)

Appendix E: Underground Storage Tank Data #12;Annual Site Environmental Report Appendix E identification service Contents Status ( ) date to Corrective action Tank Out-of- assessment number date regulatory Installation Capacity Preliminary date (gallons) investigation Environmental agency Petroleum USTs

Pennycook, Steve

239

NM Underground Storage Tank Registration | Open Energy Information  

Open Energy Info (EERE)

OpenEI Reference LibraryAdd to library Legal Document- OtherOther: NM Underground Storage Tank RegistrationLegal Published NA Year Signed or Took Effect 2012 Legal Citation...

240

Colorado Natural Gas in Underground Storage (Base Gas) (Million...  

Annual Energy Outlook 2012 (EIA)

Base Gas) (Million Cubic Feet) Colorado Natural Gas in Underground Storage (Base Gas) (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 39,062 39,062...

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

,"Colorado Natural Gas Underground Storage Net Withdrawals (MMcf...  

U.S. Energy Information Administration (EIA) Indexed Site

,,"(202) 586-8800",,,"1302015 12:57:42 PM" "Back to Contents","Data 1: Colorado Natural Gas Underground Storage Net Withdrawals (MMcf)" "Sourcekey","N5070CO2"...

242

ARM 17-56 - Underground Storage Tanks Petroleum and Chemical...  

Open Energy Info (EERE)

Underground Storage Tanks Petroleum and Chemical Substance Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- RegulationRegulation: ARM 17-56 -...

243

Alaska Underground Storage Tanks Website | Open Energy Information  

Open Energy Info (EERE)

Tanks Website Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Alaska Underground Storage Tanks Website Author Division of Spill Prevention and Response...

244

30 TAC, part 1, chapter 334 Underground storage tanks general...  

Open Energy Info (EERE)

Underground storage tanks general provisions Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- RegulationRegulation: 30 TAC, part 1, chapter 334...

245

Investigating dynamic underground coal fires by means of numerical simulation  

Science Journals Connector (OSTI)

......available within the combustion centre. Combustion will only proceed whenever...controls the overall combustion rate. For numerical...transport-only and a chemistry-only part. Common...rate of underground coal fires by oxygen transport......

S. Wessling; W. Kessels; M. Schmidt; U. Krause

2008-01-01T23:59:59.000Z

246

,"New York Natural Gas Underground Storage Net Withdrawals (MMcf...  

U.S. Energy Information Administration (EIA) Indexed Site

,,"(202) 586-8800",,,"182015 12:49:33 PM" "Back to Contents","Data 1: New York Natural Gas Underground Storage Net Withdrawals (MMcf)" "Sourcekey","N5070NY2"...

247

,"New York Natural Gas Underground Storage Net Withdrawals (MMcf...  

U.S. Energy Information Administration (EIA) Indexed Site

,,"(202) 586-8800",,,"182015 12:49:32 PM" "Back to Contents","Data 1: New York Natural Gas Underground Storage Net Withdrawals (MMcf)" "Sourcekey","N5070NY2"...

248

Underground helium travels to the Earth's surface via aquifers...  

NLE Websites -- All DOE Office Websites (Extended Search)

carried to the surface with the flow of water. The only place where helium is made on Earth is underground, where deep veins of uranium and thorium give off atoms of helium as...

249

ANALYSIS OF METHANE PRODUCING COMMUNITIES WITHIN UNDERGROUND COAL BEDS  

E-Print Network (OSTI)

ANALYSIS OF METHANE PRODUCING COMMUNITIES WITHIN UNDERGROUND COAL BEDS by Elliott Paul Barnhart ..................................................................................14 Ability of the Consortium to Produce Methane from Coal and Metabolites ................16.............................................................................................21 Coal and Methane Production

Maxwell, Bruce D.

250

Physical security of cut-and-cover underground facilities  

SciTech Connect

To aid designers, generic physical security objectives and design concepts for cut-and-cover underground facilities are presented. Specific aspects addressing overburdens, entryways, security doors, facility services, emergency egress, security response force, and human elements are discussed.

Morse, W.D.

1998-08-01T23:59:59.000Z

251

Microsoft Word - WIPP Updates_Underground Recovery Process Begins  

NLE Websites -- All DOE Office Websites (Extended Search)

5DR0314 002NWPR0314 NWP Media Contacts: Donavan Mager Nuclear Waste Partnership LLC (575) 234-7586 www.wipp.energy.gov For Immediate Release WIPP UPDATES: Underground Recovery...

252

P-wave Spectra from Underground Nuclear Explosions  

Science Journals Connector (OSTI)

......three underground explosions at the Nevada Test Site and three earthquakes recorded...nuclear explosions detonated in Nevada (Jorum and Handley) and for a...spectra from two explosions at the Nevada Test Site (Jorum and Handley) and a presumed......

Peter Molnar

1971-08-01T23:59:59.000Z

253

,"New York Natural Gas Underground Storage Capacity (MMcf)"  

U.S. Energy Information Administration (EIA) Indexed Site

,,"(202) 586-8800",,,"1162014 3:07:28 PM" "Back to Contents","Data 1: New York Natural Gas Underground Storage Capacity (MMcf)" "Sourcekey","N5290NY2"...

254

,"New York Natural Gas Underground Storage Withdrawals (MMcf...  

U.S. Energy Information Administration (EIA) Indexed Site

,,"(202) 586-8800",,,"1162014 3:06:47 PM" "Back to Contents","Data 1: New York Natural Gas Underground Storage Withdrawals (MMcf)" "Sourcekey","N5060NY2"...

255

,"New York Natural Gas Underground Storage Withdrawals (MMcf...  

U.S. Energy Information Administration (EIA) Indexed Site

,,"(202) 586-8800",,,"1162014 3:06:48 PM" "Back to Contents","Data 1: New York Natural Gas Underground Storage Withdrawals (MMcf)" "Sourcekey","N5060NY2"...

256

,"New York Natural Gas Underground Storage Capacity (MMcf)"  

U.S. Energy Information Administration (EIA) Indexed Site

,,"(202) 586-8800",,,"1162014 3:07:27 PM" "Back to Contents","Data 1: New York Natural Gas Underground Storage Capacity (MMcf)" "Sourcekey","N5290NY2"...

257

Underground Salt Haul Truck Fire at the Waste Isolation Pilot...  

Office of Environmental Management (EM)

Underground Salt Haul Truck Fire at the Waste Isolation Pilot Plant February 5, 2014 March 2014 Salt Haul Truck Fire at the Waste Isolation Pilot Plant Salt Haul Truck Fire at the...

258

One-man video verite: thoughts on Scenes from underground  

E-Print Network (OSTI)

This thesis considers the making of a documentary videotape on the Red Line Subway Extension project in Cambridge and Somerville, Massachusetts entitled Scenes From Underground. It traces my initial plans for an expository ...

Strongin, Barry

1984-01-01T23:59:59.000Z

259

Recreation motivators and facility factors as relative determinants of urban outdoor recreation behavior and satisfaction  

E-Print Network (OSTI)

RECREATION MOTIVATORS AND FACILITY FACTORS AS RELATIVE DETERMINANTS OF URBAN OUTDOOR RECREATION BEHAVIOR AND SATISFACTION A Thesis by JEFFREY STEPHEN MILKES Submitted to the Graduate College of Texas A8M University in partial fulfillment... of the requirement for the degree of MASTER OF SCIENCE August 1987 Major Subject: Recreation and Resource Development RECREATION MOTIVATORS AND FACILITY FACTORS AS RELATIVE DETERMINANTS OF URBAN OUTDOOR RECREATION BEHAVIOR AND SATISFACTION A Thesis...

Milkes, Jeffrey Stephen

2012-06-07T23:59:59.000Z

260

Economizer control assembly for regulating the volume flow of outdoor ambient air  

SciTech Connect

An economizer assembly is disclosed wherein a sliding door is utilized for covering an outdoor ambient air opening allowing outdoor ambient air flow into a space to be conditioned. A motor shaft arrangement connected via a rotating drive rod is utilized to slidably displace the door to any position necessary to effectively regulate air flow. The utilization of this economizer control arrangement with a rooftop type air conditioning unit is further disclosed.

Michaels, D.D. Jr.

1984-10-23T23:59:59.000Z

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

A comparative study of selected agencies providing outdoor adventure programs for youth-at-risk  

E-Print Network (OSTI)

and guidance in the midst of growing up. Outdoor adventure programs instill an appreciation for the wilderness, provide an acceptable way for the participants to make use of leisure time, challenge themselves and experience "risk" in a socially acceptable... and guidance in the midst of growing up. Outdoor adventure programs instill an appreciation for the wilderness, provide an acceptable way for the participants to make use of leisure time, challenge themselves and experience "risk" in a socially acceptable...

Keck, Mary A.

2012-06-07T23:59:59.000Z

262

Waste package and underground facility design  

SciTech Connect

The design of the waste package and the underground facility for radioactive waste disposal presents many challenges never before addressed in an engineering design effort. The designs must allow for handling and emplacement of the waste and must ensure that the waste will be isolated over time periods that extend beyond those normally dealt with in engineering solutions. Once developed, these designs must be defended in a licensing arena to allow construction and operation of the disposal system. The design of the waste package and the repository is being conducted iteratively. Each iteration of the design is accompanied by an assessment of the performance of the design and an assessment of remaining design issues. These assessments are used to establish the basis for the next design phase. Design requirements are assessed and revised as necessary before the initiation of each design phase. In addition, the design effort is being closely integrated with the siting effort through the application of an issue identification and resolution strategy.

Frei, M.W.; Dayem, N.J.

1988-01-01T23:59:59.000Z

263

Experiences and prospects of nuclear astrophysics in underground laboratories  

SciTech Connect

Impressive progress has been made in the course the last decades in understanding astrophysical objects. Increasing precision of nuclear physics data has contributed significantly to this success, but now a better understanding of several important findings is frequently limited by uncertainties related to the available nuclear physics data. Consequently it is desirable to improve significantly the quality of these data. An important step towards higher precision is an excellent signal to background ratio of the data. Placing an accelerator facility inside an underground laboratory reducing the cosmic ray induced background by six orders of magnitude is a powerful method to reach this goal, even though careful reduction of environmental and beam induced background must still be considered. Experience in the field of underground nuclear astrophysics has been gained since 20 years due to the pioneering work of the LUNA Collaboration (Laboratory for Underground Nuclear Astrophysics) operating inside the underground laboratories of the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. Based on the success of this work presently also several other projects for underground laboratories dedicated to nuclear astrophysics are being pursued worldwide. This contribution will give a survey of the past experience in underground nuclear astrophysics as well as an outlook on future developments.

Junker, M. [INFN - Laboratori Nazionali del Gran Sasso, Via Acitelli, 22, 67100 L'Aquila, Località Assergi (Italy)

2014-05-09T23:59:59.000Z

264

Safety of Hydrogen Systems Installed in Outdoor Enclosures  

SciTech Connect

The Hydrogen Safety Panel brings a broad cross-section of expertise from the industrial, government, and academic sectors to help advise the U.S. Department of Energy’s (DOE) Fuel Cell Technologies Office through its work in hydrogen safety, codes, and standards. The Panel’s initiatives in reviewing safety plans, conducting safety evaluations, identifying safety-related technical data gaps, and supporting safety knowledge tools and databases cover the gamut from research and development to demonstration and deployment. The Panel’s recent work has focused on the safe deployment of hydrogen and fuel cell systems in support of DOE efforts to accelerate fuel cell commercialization in early market applications: vehicle refueling, material handling equipment, backup power for warehouses and telecommunication sites, and portable power devices. This paper resulted from observations and considerations stemming from the Panel’s work on early market applications. This paper focuses on hydrogen system components that are installed in outdoor enclosures. These enclosures might alternatively be called “cabinets,” but for simplicity, they are all referred to as “enclosures” in this paper. These enclosures can provide a space where a flammable mixture of hydrogen and air might accumulate, creating the potential for a fire or explosion should an ignition occur. If the enclosure is large enough for a person to enter, and ventilation is inadequate, the hydrogen concentration could be high enough to asphyxiate a person who entered the space. Manufacturers, users, and government authorities rely on requirements described in codes to guide safe design and installation of such systems. Except for small enclosures used for hydrogen gas cylinders (gas cabinets), fuel cell power systems, and the enclosures that most people would describe as buildings, there are no hydrogen safety requirements for these enclosures, leaving gaps that must be addressed. This paper proposes that a technical basis be developed to enable code bodies to write requirements for the range of enclosures from the smallest to the largest.

Barilo, Nick F.

2013-11-06T23:59:59.000Z

265

College of Agricultural Sciences Cooperative Extension Growing Herbs Outdoors  

E-Print Network (OSTI)

to be grown based on the light exposure of the site they will be planted in. This information can be found, horticultural sand, vermiculite, and/or compost in with the soil, backfill the area, and then level the soil

Guiltinan, Mark

266

Text-Alternative Version of TAP Webinar: High Performance Outdoor...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

and light trespass, and it functions well in cold temperatures, not affected by vibration. I've invited one of our colleagues from the labs to join us on the call in the...

267

Underground physics without underground labs: large detectors in solution-mined salt caverns  

E-Print Network (OSTI)

A number of current physics topics, including long-baseline neutrino physics, proton decay searches, and supernova neutrino searches, hope to someday construct huge (50 kiloton to megaton) particle detectors in shielded, underground sites. With today's practices, this requires the costly excavation and stabilization of large rooms in mines. In this paper, we propose utilizing the caverns created by the solution mining of salt. The challenge is that such caverns must be filled with pressurized fluid and do not admit human access. We sketch some possible methods of installing familiar detector technologies in a salt cavern under these constraints. Some of the detectors discussed are also suitable for deep-sea experiments, discussed briefly. These sketches appear challenging but feasible, and appear to force few major compromises on detector capabilities. This scheme offers avenues for enormous cost savings on future detector megaprojects.

Benjamin Monreal

2014-09-30T23:59:59.000Z

268

Underground physics without underground labs: large detectors in solution-mined salt caverns  

E-Print Network (OSTI)

A number of current physics topics, including long-baseline neutrino physics, proton decay searches, and supernova neutrino searches, hope to someday construct huge (50 kiloton to megaton) particle detectors in shielded, underground sites. With today's practices, this requires the costly excavation and stabilization of large rooms in mines. In this paper, we propose utilizing the caverns created by the solution mining of salt. The challenge is that such caverns must be filled with pressurized fluid and do not admit human access. We sketch some possible methods of installing familiar detector technologies in a salt cavern under these constraints. Some of the detectors discussed are also suitable for deep-sea experiments, discussed briefly. These sketches appear challenging but feasible, and appear to force few major compromises on detector capabilities. This scheme offers avenues for enormous cost savings on future detector megaprojects.

Monreal, Benjamin

2014-01-01T23:59:59.000Z

269

Low-Pressure Sodium Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Low-Pressure Sodium Lighting Basics Low-Pressure Sodium Lighting Basics Low-Pressure Sodium Lighting Basics August 16, 2013 - 10:17am Addthis Low-pressure sodium lighting provides more energy-efficient outdoor lighting than high-intensity discharge lighting, but it has very poor color rendition. Typical applications include highway and security lighting, where color is not important. Low-pressure sodium lamps work somewhat like fluorescent lamps. Like high-intensity discharge lighting, low-pressure sodium lamps require up to 10 minutes to start and have to cool before they can restart. Therefore, they are most suitable for applications in which they stay on for hours at a time. They are not suitable for use with motion detectors. The chart below compares low-pressure sodium lamps and high-intensity

270

The effects of outdoor heat exchanger hydrophobic treatment on the performance of an air source heat pump.  

E-Print Network (OSTI)

??The effects of outdoor heat exchanger hydrophobic treatment on the performance of an air source heat pump were investigated. The base case tests used a… (more)

Parker, Brandon DeWayne

2012-01-01T23:59:59.000Z

271

New Texas Oil Project Will Help Keep Carbon Dioxide Underground |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Texas Oil Project Will Help Keep Carbon Dioxide Underground Texas Oil Project Will Help Keep Carbon Dioxide Underground New Texas Oil Project Will Help Keep Carbon Dioxide Underground February 5, 2013 - 12:05pm Addthis The Air Products and Chemicals hydrogen production facilities in Port Arthur, Texas, is funded by the Energy Department through the 2009 Recovery Act. It is managed by the Office of Fossil Energy’s National Energy Technology Laboratory. | Photo credit Air Products and Chemicals hydrogen production facilities. The Air Products and Chemicals hydrogen production facilities in Port Arthur, Texas, is funded by the Energy Department through the 2009 Recovery Act. It is managed by the Office of Fossil Energy's National Energy Technology Laboratory. | Photo credit Air Products and Chemicals hydrogen

272

New Texas Oil Project Will Help Keep Carbon Dioxide Underground |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New Texas Oil Project Will Help Keep Carbon Dioxide Underground New Texas Oil Project Will Help Keep Carbon Dioxide Underground New Texas Oil Project Will Help Keep Carbon Dioxide Underground February 5, 2013 - 12:05pm Addthis The Air Products and Chemicals hydrogen production facilities in Port Arthur, Texas, is funded by the Energy Department through the 2009 Recovery Act. It is managed by the Office of Fossil Energy’s National Energy Technology Laboratory. | Photo credit Air Products and Chemicals hydrogen production facilities. The Air Products and Chemicals hydrogen production facilities in Port Arthur, Texas, is funded by the Energy Department through the 2009 Recovery Act. It is managed by the Office of Fossil Energy's National Energy Technology Laboratory. | Photo credit Air Products and Chemicals hydrogen

273

Underground Injection Control (West Virginia) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Injection Control (West Virginia) Injection Control (West Virginia) Underground Injection Control (West Virginia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State West Virginia Program Type Siting and Permitting Provider Department of Environmental Protection This rule set forth criteria and standards for the requirements which apply to the State Underground Injection Control Program (U.I.C.). The UIC permit program regulates underground injections by 5 classes of wells. All owners

274

Solid Waste Disposal, Hazardous Waste Management Act, Underground Storage  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Disposal, Hazardous Waste Management Act, Underground Disposal, Hazardous Waste Management Act, Underground Storage Act (Tennessee) Solid Waste Disposal, Hazardous Waste Management Act, Underground Storage Act (Tennessee) < Back Eligibility Agricultural Commercial Construction Developer Fuel Distributor Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Municipal/Public Utility Nonprofit Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Tribal Government Utility Program Info State Tennessee Program Type Environmental Regulations Siting and Permitting Provider Tennessee Department Of Environment and Conservation The Solid Waste Disposal Laws and Regulations are found in Tenn. Code 68-211. These rules are enforced and subject to change by the Public Waste Board (PWB), which is established by the Division of Solid and Hazardous

275

Western Consuming Region Natural Gas Working Underground Storage (Billion  

Gasoline and Diesel Fuel Update (EIA)

Western Consuming Region Natural Gas Working Underground Storage (Billion Cubic Feet) Western Consuming Region Natural Gas Working Underground Storage (Billion Cubic Feet) Western Consuming Region Natural Gas Working Underground Storage (Billion Cubic Feet) Year-Month Week 1 Week 2 Week 3 Week 4 Week 5 End Date Value End Date Value End Date Value End Date Value End Date Value 1993-Dec 12/31 341 1994-Jan 01/07 331 01/14 316 01/21 303 01/28 290 1994-Feb 02/04 266 02/11 246 02/18 228 02/25 212 1994-Mar 03/04 206 03/11 201 03/18 205 03/25 202 1994-Apr 04/01 201 04/08 201 04/15 202 04/22 210 04/29 215 1994-May 05/06 225 05/13 236 05/20 242 05/27 256

276

Underground storage of natural gas, liquid hydrocarbons, and carbon dioxide  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

storage of natural gas, liquid hydrocarbons, and carbon storage of natural gas, liquid hydrocarbons, and carbon dioxide (Louisiana) Underground storage of natural gas, liquid hydrocarbons, and carbon dioxide (Louisiana) < Back Eligibility Commercial Construction Industrial Investor-Owned Utility Municipal/Public Utility Utility Program Info State Louisiana Program Type Environmental Regulations Siting and Permitting The Louisiana Department of Environmental Quality regulates the underground storage of natural gas or liquid hydrocarbons and carbon dioxide. Prior to the use of any underground reservoir for the storage of natural gas and prior to the exercise of eminent domain by any person, firm, or corporation having such right under laws of the state of Louisiana, the commissioner, shall have found all of the following:

277

Nonsalt Producing Region Natural Gas Working Underground Storage (Billion  

Gasoline and Diesel Fuel Update (EIA)

Nonsalt Producing Region Natural Gas Working Underground Storage (Billion Cubic Feet) Nonsalt Producing Region Natural Gas Working Underground Storage (Billion Cubic Feet) Nonsalt Producing Region Natural Gas Working Underground Storage (Billion Cubic Feet) Year-Month Week 1 Week 2 Week 3 Week 4 Week 5 End Date Value End Date Value End Date Value End Date Value End Date Value 2006-Dec 12/29 841 2007-Jan 01/05 823 01/12 806 01/19 755 01/26 716 2007-Feb 02/02 666 02/09 613 02/16 564 02/23 538 2007-Mar 03/02 527 03/09 506 03/16 519 03/23 528 03/30 550 2007-Apr 04/06 560 04/13 556 04/20 568 04/27 590 2007-May 05/04 610 05/11 629 05/18 648 05/25 670

278

Office of Enforcement Final Notice of Violation to Pacific Underground  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Enforcement Final Notice of Violation to Pacific Enforcement Final Notice of Violation to Pacific Underground Construction, Inc. September 3, 2009 Office of Enforcement Final Notice of Violation to Pacific Underground Construction, Inc. September 3, 2009 Pursuant to section 234C of the Atomic Energy Act, as amended, 42 U.S.C. § 2282c, and the Department of Energy's (DOE) regulations at 10 C.F.R. Part 851, Worker Safety and Health Program, DOE is issuing this Final Notice of Violation (FNOV) to Pacific Underground Construction, Inc. (PUC). The FNOV finds PUC liable for violating DOE's worker safety and health requirements. The FNOV is based upon the Office of Enforcement's July 23, 2008, Investigation Report and a careful and thorough review of all evidence presented to DOE by PUC, including your response to the Preliminary Notice

279

Underground radio technology saves miners and emergency response personnel  

NLE Websites -- All DOE Office Websites (Extended Search)

Underground radio technology saves miners and emergency response Underground radio technology saves miners and emergency response personnel Underground radio technology saves miners and emergency response personnel Founded through LANL, Vital Alert Technologies, Inc. (Vital Alert) has launched a wireless, two-way real-time voice communication system that is effective through 1,000+ feet of solid rock. April 3, 2012 Vital Alert's C1000 mine and tunnel radios use magnetic induction, advanced digital communications techniques and ultra-low frequency transmission to wirelessly provide reliable 2-way voice, text, or data links through rock strata and other solid media. Vital Alert's C1000 mine and tunnel radios use magnetic induction, advanced digital communications techniques and ultra-low frequency transmission to wirelessly provide reliable 2-way voice, text, or data links through rock

280

Producing Region Natural Gas Working Underground Storage (Billion Cubic  

Gasoline and Diesel Fuel Update (EIA)

Producing Region Natural Gas Working Underground Storage (Billion Cubic Feet) Producing Region Natural Gas Working Underground Storage (Billion Cubic Feet) Producing Region Natural Gas Working Underground Storage (Billion Cubic Feet) Year-Month Week 1 Week 2 Week 3 Week 4 Week 5 End Date Value End Date Value End Date Value End Date Value End Date Value 1993-Dec 12/31 570 1994-Jan 01/07 532 01/14 504 01/21 440 01/28 414 1994-Feb 02/04 365 02/11 330 02/18 310 02/25 309 1994-Mar 03/04 281 03/11 271 03/18 284 03/25 303 1994-Apr 04/01 287 04/08 293 04/15 308 04/22 334 04/29 353 1994-May 05/06 376 05/13 399 05/20 429 05/27 443

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Ningbo Liaoyuan Lighting Co | Open Energy Information  

Open Energy Info (EERE)

Liaoyuan Lighting Co Liaoyuan Lighting Co Jump to: navigation, search Name Ningbo Liaoyuan Lighting Co Place Yuyao, Zhejiang Province, China Zip 315408 Sector Solar, Wind energy Product Engaged in outdoor LED lighting manufacture and design including street lamps and solar/wind hybrid street lamps. Coordinates 30.047501°, 121.151222° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":30.047501,"lon":121.151222,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

282

Underground Storage Tanks (West Virginia) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tanks (West Virginia) Tanks (West Virginia) Underground Storage Tanks (West Virginia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State West Virginia Program Type Siting and Permitting Provider Department of Environmental Protection This rule governs the construction, installation, upgrading, use, maintenance, testing, and closure of underground storage tanks, including certification requirements for individuals who install, repair, retrofit,

283

Underground Gas Storage Reservoirs (West Virginia) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Gas Storage Reservoirs (West Virginia) Gas Storage Reservoirs (West Virginia) Underground Gas Storage Reservoirs (West Virginia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State West Virginia Program Type Safety and Operational Guidelines Provider West Virginia Department of Commerce Lays out guidelines for the conditions under which coal mining operations must notify state authorities of intentions to mine where underground gas

284

Control Surveys for Underground Construction of the Superconducting Super Collider  

SciTech Connect

Particular care had to be taken in the design and implementation of the geodetic control systems for the Superconducting Super Collider (SSC) due to stringent accuracy requirements, the demanding tunneling schedule, long duration and large size of the construction effort of the project. The surveying requirements and the design and implementation of the surface and underground control scheme for the precise location of facilities which include approximately 120 km of bored tunnel are discussed. The methodology used for the densification of the surface control networks, the technique used for the transfer of horizontal and vertical control into the underground facilities, and the control traverse scheme employed in the tunnels is described.

Greening, W.J.Trevor; Robinson, Gregory L.; /Measurment Science Inc.; Robbins, Jeffrey S.; Ruland, Robert E.; /SLAC

2005-08-16T23:59:59.000Z

285

Sudden stratospheric warmings seen in MINOS deep underground muon data  

SciTech Connect

The rate of high energy cosmic ray muons as measured underground is shown to be strongly correlated with upper-air temperatures during short-term atmospheric (10-day) events. The effects are seen by correlating data from the MINOS underground detector and temperatures from the European Centre for Medium Range Weather Forecasts during the winter periods from 2003-2007. This effect provides an independent technique for the measurement of meteorological conditions and presents a unique opportunity to measure both short and long-term changes in this important part of the atmosphere.

Osprey, S.; /Oxford U.; Barnett, J.; /Oxford U.; Smith, J.; /Oxford U.; Adamson, P.; /Fermilab; Andreopoulos, C.; /Rutherford; Arms, K.E.; /Minnesota U.; Armstrong, R.; /Indiana U.; Auty, D.J.; /Sussex U.; Ayres, D.S.; /Argonne; Baller, B.; /Fermilab; Barnes, P.D., Jr.; /LLNL, Livermore /Oxford U.

2009-01-01T23:59:59.000Z

286

Microsoft Word - Outdoor Small- and Pilot-Scale Research and Development 3768X_final  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Outdoor, Small- and Pilot-Scale Research and Development (3768X) Outdoor, Small- and Pilot-Scale Research and Development (3768X) Program or Field Office: Office of Science - ORNL Location(s) (City/County/State): Oak Ridge, Tennessee Proposed Action Description: The U.S. Department of Energy Oak Ridge National Laboratory (ORNL) Site Office (DOE-OSO) proposes to conduct outdoor, small- and pilot-scale research and development activities and associated transfer, lease, disposition or acquisition of interests in personal or real property involving advanced materials, biological and ecological systems, energy science, and national security including but not limited to collecting samples and analyzing ecosystem and atmospheric field data; developing, evaluating and testing equipment, materials and components; and

287

Solar Decathlon Design Places People and the Outdoors at its Heart |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Decathlon Design Places People and the Outdoors at its Heart Solar Decathlon Design Places People and the Outdoors at its Heart Solar Decathlon Design Places People and the Outdoors at its Heart May 26, 2011 - 5:57pm Addthis Members of Team New Zealand | Courtesy of the New Zealand team's Flickr photostream Members of Team New Zealand | Courtesy of the New Zealand team's Flickr photostream Erin R. Pierce Erin R. Pierce Digital Communications Specialist, Office of Public Affairs How can I participate? The next Solar Decathlon will be held Sept. 23-Oct. 2, 2011, at the National Mall's West Potomac Park in Washington, D.C. In honor of the U.S Department of Energy's Solar Decathlon -- which challenges 20 collegiate teams to design, build and operate solar-powered houses that are cost-effective, energy-efficient and attractive -- we are

288

B3.11 SWCX for Outdoor Tests, Experiments on Materials and Equipment Components-  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 SWCX for Outdoor Tests, Experiments on Materials and Equipment Components- 1 SWCX for Outdoor Tests, Experiments on Materials and Equipment Components- Revision 0 Sitewide Categorical Exclusion for Outdoor Tests, Experiments on Materials and Equipment Components Introduction .A .. s defined in the U.S. Department of Energy's (DOE) Richland Operations Office Integrated Management System Procedure, NEPA Analysis at Hanford, a sitewide categorical exclusion is: An application of DOE categorical exclusions described in 10 CFR 1021, Appendices A and B, which may apply to Hanford Site proposed actions (activities) that are "sitewide" in nature and extent, which the cognizant DOE Hanford NCO has determined fit within the scope (i.e., same n

289

Solar Decathlon Design Places People and the Outdoors at its Heart |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Decathlon Design Places People and the Outdoors at its Heart Solar Decathlon Design Places People and the Outdoors at its Heart Solar Decathlon Design Places People and the Outdoors at its Heart May 26, 2011 - 5:57pm Addthis Members of Team New Zealand | Courtesy of the New Zealand team's Flickr photostream Members of Team New Zealand | Courtesy of the New Zealand team's Flickr photostream Erin R. Pierce Erin R. Pierce Digital Communications Specialist, Office of Public Affairs How can I participate? The next Solar Decathlon will be held Sept. 23-Oct. 2, 2011, at the National Mall's West Potomac Park in Washington, D.C. In honor of the U.S Department of Energy's Solar Decathlon -- which challenges 20 collegiate teams to design, build and operate solar-powered houses that are cost-effective, energy-efficient and attractive -- we are

290

Indoor and Outdoor in Situ High-Resolution Gamma Radiation Measurements in Urban Areas of Cyprus  

E-Print Network (OSTI)

In situ, high-resolution, gamma-ray spectrometry of a total number of 70 outdoor and 20 indoor representative measurements were performed in preselected, common locations of the main urban areas of Cyprus. Specific activities and gamma absorbed dose rates in air due to the naturally occurring radionuclides of Th-232 and U-238 series, and K-40 are determined and discussed. Effective dose rate to the Cyprus population due to terrestrial gamma radiation is derived directly from this work. The results obtained outdoors match very well with those derived previously by high-resolution gamma spectrometry of soil samples, which were collected from the main island bedrock surface. This implies that the construction and building materials in urban areas do not affect the external gamma dose rate; thus they are mostly of local origin. Finally, the indoor/outdoor gamma dose ratio was found to be 1.4 +- 0.5.

E. Svoukis; H. Tsertos

2006-10-02T23:59:59.000Z

291

H.A.R. 11-281 - Underground Storage Tanks | Open Energy Information  

Open Energy Info (EERE)

1 - Underground Storage Tanks Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- RegulationRegulation: H.A.R. 11-281 - Underground Storage...

292

Horizontal Hydraulic Conductivity Estimates for Intact Coal Barriers Between Closed Underground Mines  

Science Journals Connector (OSTI)

...discharges were obtained from industry reports stored at the Consol...mining beneath surface water and waste impoundments: In Proceedings...associated with underground coal gasification: Canadian Geotechnical Journal...underground mining United States waste disposal water quality West...

KURT J. McCOY; JOSEPH J. DONOVAN; BRUCE R. LEAVITT

293

C.R.S. 37-90 - Underground Water | Open Energy Information  

Open Energy Info (EERE)

StatuteStatute: C.R.S. 37-90 - Underground WaterLegal Abstract This article governs the management of underground water in Colorado. Published NA Year Signed or Took Effect 2014...

294

Assessment of seawater intrusion into underground oil storage cavern and prediction of its sustainability  

Science Journals Connector (OSTI)

Operation of underground oil (gas) storage cavern in coastal area can induce seawater intrusion because excavation of underground storage cavern causes the groundwater level decrease of coastal aquifer. Seawater ...

Eunhee Lee; Jeong-Won Lim; Hee Sun Moon; Kang-Kun Lee

2014-07-01T23:59:59.000Z

295

Managing expert-information uncertainties for assessing collapse susceptibility of abandoned underground structures  

E-Print Network (OSTI)

by the vast number of quarries and marl pits, but also for various other reasons resulting in underground be sufficiently violent to cause human loss. Thus, in 1961, the collapse of an underground chalk quarry

Boyer, Edmond

296

Swedish spatial planning: A blunt instrument for the protection of outdoor recreation  

Science Journals Connector (OSTI)

Abstract Outdoor recreation opportunities are in great demand across Europe—so much so that for many citizens it affects their choice of where to live. National authorities, for example the Swedish Environmental Protection Agency (2005), have stressed that municipal spatial planning (i.e. local land use planning) should be used to protect outdoor recreation. However, the circumstances under which outdoor recreation is integrated into spatial planning remain unclear. The study draws on a survey of Swedish citizens, and another survey of planning officials representing all 290 Swedish municipalities, qualitative interviews with ten municipal planning officials, and analyses of comprehensive planning documents in eleven municipalities. Based on a discussion of the supply of and demand for urban and peri-urban nature, the results show that in Sweden spatial planning is an important, but somewhat blunt instrument for the protection of nature areas suitable for outdoor recreation. It is argued that, a combination of the following planning measures would make it more effective: (i) increased public participation in the planning process; (ii) greater use of research-based knowledge of outdoor recreation; (iii) umbrella legislation for outdoor recreation; (iv) changes to the wording of the legislation; and (v) research on providing clearer definitions and their implementation to planning. Management implications This case study about the position of outdoor recreation in Swedish planning processes bears relevance for an international audience of practitioners and researchers. In Sweden, outdoor recreation as public interest carries very high rhetorical value, but both the spatial planning practice and the planning legislation carry notable weaknesses in defense of these interests. The following strategies are proposed to alleviate this situation: – Knowledge about public recreation and suitable natural areas in and around urban areas needs to be communicated at all levels of spatial planning, to support the required trade-offs between competing interests. – The high demand for recreational opportunities close to people?s homes is one particularly strong argument for defending the public interest. – In order to strengthen public participation, the planning process should be made more transparent, public meetings should be made more inviting, and be held at suitable times. Participation and knowledge transfer can also be enhanced by new methods such as geographic information systems (Soft GIS) that allow residents to share their knowledge of their living environment with urban planners and researchers.

Lena Petersson-Forsberg

2014-01-01T23:59:59.000Z

297

Dynamic thermal simulation of a glass-covered semi-outdoor space with roof evaporative cooling  

Science Journals Connector (OSTI)

In the hot season solar radiation impinging on a glass roofing may overheat the underneath space to temperature values which may generate a high stress environment. To moderate the extreme microclimate which may occur in a glass covered semi-outdoor space, evaporative cooling to be applied to the glass roof is suggested. The analysis is performed under both the thermal and the energetic point of view, by accounting for the actual climate of the considered location. The results point out that roof evaporative cooling coupled with glass sheet high solar radiation absorptivity may offer an attractive way for the control of a semi-outdoor environment.

G. Pagliarini; S. Rainieri

2011-01-01T23:59:59.000Z

298

Benefits and costs of tourism and outdoor recreation in the Natural Park of the Ampezzo Dolomites (Veneto-Italy)  

E-Print Network (OSTI)

1 Benefits and costs of tourism and outdoor recreation in the Natural Park of the Ampezzo Dolomites economy. The Alps Agreement too, with particular regard to Tourism Protocol has underlined that tourism development has to be sustainable. Therefore, we need to know tourism and outdoor recreation benefits

Tempesta, Tiziano

299

STUDY OF FROST GROWTH ON HEAT EXCHANGERS USED AS OUTDOOR COILS IN AIR SOURCE HEAT PUMP SYSTEMS  

E-Print Network (OSTI)

STUDY OF FROST GROWTH ON HEAT EXCHANGERS USED AS OUTDOOR COILS IN AIR SOURCE HEAT PUMP SYSTEMS OF FROST GROWTH ON HEAT EXCHANGERS USED AS OUTDOOR COILS IN AIR SOURCE HEAT PUMP SYSTEMS Dissertation . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 3.5.3 Air Side Heat Transfer Rates . . . . . . . . . . . . . . . . . . 43 3.5.4 Fluid Side Heat

300

2008 ITE Data Collection Project Proposal Project Type: Outdoor Sport Field Trip and Parking Generation Data Collection  

E-Print Network (OSTI)

2008 ITE Data Collection Project Proposal Project Type: Outdoor Sport Field Trip and Parking Generation Data Collection The Portland State University ITE Chapter proposes to collect multimodal trip and parking generation data for an outdoor school sport field. This effort is intended to complement

Bertini, Robert L.

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Lower 48 States Natural Gas Underground Storage Withdrawals (Million Cubic  

U.S. Energy Information Administration (EIA) Indexed Site

Gas Underground Storage Withdrawals (Million Cubic Feet) Gas Underground Storage Withdrawals (Million Cubic Feet) Lower 48 States Natural Gas Underground Storage Withdrawals (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2011 849,115 666,248 313,952 100,096 58,314 80,472 115,649 125,989 55,418 51,527 183,799 473,674 2012 619,332 515,817 205,365 126,403 73,735 90,800 129,567 133,919 66,652 85,918 280,933 489,707 2013 791,849 646,483 480,032 134,680 48,945 68,117 98,141 101,568 66,273 - = No Data Reported; -- = Not Applicable; NA = Not Available; W = Withheld to avoid disclosure of individual company data. Release Date: 12/12/2013 Next Release Date: 1/7/2014 Referring Pages: Withdrawals of Natural Gas from Underground Storage - All Operators

302

Appendix C: Underground Storage Annual Site Environmental Report  

E-Print Network (OSTI)

Appendix C: Underground Storage Tank Data #12;#12;Annual Site Environmental Report Appendix C identification service Contents Status ( ) date to Corrective action Tank Out-of- assessment number date regulatory Installation Capacity Preliminary date (gallons) investigation Environmental agency Petroleum USTs

Pennycook, Steve

303

Coal properties and system operating parameters for underground coal gasification  

SciTech Connect

Through the model experiment for underground coal gasification, the influence of the properties for gasification agent and gasification methods on underground coal gasifier performance were studied. The results showed that pulsating gasification, to some extent, could improve gas quality, whereas steam gasification led to the production of high heating value gas. Oxygen-enriched air and backflow gasification failed to improve the quality of the outlet gas remarkably, but they could heighten the temperature of the gasifier quickly. According to the experiment data, the longitudinal average gasification rate along the direction of the channel in the gasifying seams was 1.212 m/d, with transverse average gasification rate 0.069 m/d. Experiment indicated that, for the oxygen-enriched steam gasification, when the steam/oxygen ratio was 2:1, gas compositions remained stable, with H{sub 2} + CO content virtually standing between 60% and 70% and O{sub 2} content below 0.5%. The general regularities of the development of the temperature field within the underground gasifier and the reasons for the changes of gas quality were also analyzed. The 'autopneumatolysis' and methanization reaction existing in the underground gasification process were first proposed.

Yang, L. [China University of Mining & Technology, Xuzhou (China)

2008-07-01T23:59:59.000Z

304

Effect of repository underground ventilation on emplacement drift temperature control  

SciTech Connect

The repository advanced conceptual design (ACD) is being conducted by the Civilian Radioactive Waste Management System, Management & Operating Contractor. Underground ventilation analyses during ACD have resulted in preliminary ventilation concepts and design methodologies. This paper discusses one of the recent evaluations -- effects of ventilation on emplacement drift temperature management.

Yang, H.; Sun, Y.; McKenzie, D.G.; Bhattacharyya, K.K. [Morrison Knudson Corporation, Las Vegas, NV (United States)

1996-02-01T23:59:59.000Z

305

Case study of groundwater impact caused by underground mining  

SciTech Connect

An investigative methodology is presented to assist mining and regulatory personnel in determining the effect underground mining can have on local aquifers in the Appalachian coal region. The impact of underground mining on groundwater may be more extensive than first realized by the mining industry and regulatory agencies. The primary reason for this possible under-assessment of deep mining's influence on groundwater is the methods used to calculate groundwater movement. Since groundwater calculations are based on primary hydraulic conductivity, i.e. the conductivity through solid rock measured from rock core samples, erroneous results may be expected. In many cases, groundwater flow times and the corresponding areas of influence are much greater than those assumed since water is rapidly moved through fractured zones that commonly occur throughout Appalachia. A case study illustrating this phenomenon is drawn from underground mining operations in Pike County. A survey of 144 wells was conducted to determine if any loss of water supply and/or quality was found. This was correlated to the extent and time progression of underground mining operations. Other parameters qualified are water level fluctuations, groundwater quality, precipitation, seasonal effects, geology, and mine dewatering. The analysis includes a comprehensive compilation of a well inventory of domestic water supplies. The case study draws conclusions regarding cause and effect relationships.

Sloan, P.; Warner, R.C.

1984-12-01T23:59:59.000Z

306

Underground test area subproject waste management plan. Revision No. 1  

SciTech Connect

The Nevada Test Site (NTS), located in southern Nevada, was the site of 928 underground nuclear tests conducted between 1951 and 1992. The tests were performed as part of the Atomic Energy Commission and U.S. Department of Energy (DOE) nuclear weapons testing program. The NTS is managed by the DOE Nevada Operations Office (DOE/NV). Of the 928 tests conducted below ground surface at the NTS, approximately 200 were detonated below the water table. As an unavoidable consequence of these testing activities, radionuclides have been introduced into the subsurface environment, impacting groundwater. In the few instances of groundwater sampling, radionuclides have been detected in the groundwater; however, only a very limited investigation of the underground test sites and associated shot cavities has been conducted to date. The Underground Test Area (UGTA) Subproject was established to fill this void and to characterize the risk posed to human health and the environment as a result of underground nuclear testing activities at the NTS. One of its primary objectives is to gather data to characterize the deep aquifer underlying the NTS.

NONE

1996-08-01T23:59:59.000Z

307

Grounding Analysis in Heterogeneous Soil Models: Application to Underground Substations  

E-Print Network (OSTI)

Grounding Analysis in Heterogeneous Soil Models: Application to Underground Substations Ignasi category includes all step- up and step-down transmission substations, as well as a number of distribution substations indeed. Nevertheless, the current trend in electric power Engineering moves in another direction

Colominas, Ignasi

308

,"New York Underground Natural Gas Storage - All Operators"  

U.S. Energy Information Administration (EIA) Indexed Site

"Sourcekey","N5030NY2","N5010NY2","N5020NY2","N5070NY2","N5050NY2","N5060NY2" "Date","New York Natural Gas Underground Storage Volume (MMcf)","New York Natural Gas in...

309

Radon concentrations in three underground lignite mines in Turkey  

Science Journals Connector (OSTI)

......being operated by the Aegean Lignite Enterprise (Ege Linyitleri...determined in three underground lignite mines, namely Tuncbilek...which is the main state body of lignite coal production, processing...of TKi. GLi Tuncbilek coal reserve, which is located on the mid-west......

S. Çile; N. Altinsoy; N. Çelebi

2010-01-01T23:59:59.000Z

310

EARLY DEVELOPMENT OF THE UNDERGROUND SNO LABORATORY IN CANADA  

E-Print Network (OSTI)

EARLY DEVELOPMENT OF THE UNDERGROUND SNO LABORATORY IN CANADA by G.T. Ewan and W.F. Davidson Council of Canada, Ottawa, Ontario Fundamental physics measurements can be made by many different of high energy cos- mic rays, solar neutrino measure- ments, and searches for rare process- es

Abolmaesumi, Purang

311

Lower 48 States Total Natural Gas Injections into Underground Storage  

U.S. Energy Information Administration (EIA) Indexed Site

Total Natural Gas Injections into Underground Storage (Million Cubic Feet) Total Natural Gas Injections into Underground Storage (Million Cubic Feet) Lower 48 States Total Natural Gas Injections into Underground Storage (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2011 50,130 81,827 167,632 312,290 457,725 420,644 359,267 370,180 453,548 436,748 221,389 90,432 2012 74,854 56,243 240,351 263,896 357,965 323,026 263,910 299,798 357,109 327,767 155,554 104,953 2013 70,592 41,680 99,330 270,106 465,787 438,931 372,458 370,471 418,848 - = No Data Reported; -- = Not Applicable; NA = Not Available; W = Withheld to avoid disclosure of individual company data. Release Date: 12/12/2013 Next Release Date: 1/7/2014 Referring Pages: Injections of Natural Gas into Underground Storage - All Operators

312

Underground storage tank 511-D1U1 closure plan  

SciTech Connect

This document contains the closure plan for diesel fuel underground storage tank 511-D1U1 and appendices containing supplemental information such as staff training certification and task summaries. Precision tank test data, a site health and safety plan, and material safety data sheets are also included.

Mancieri, S.; Giuntoli, N.

1993-09-01T23:59:59.000Z

313

Growth and lipid accumulation characteristics of Scenedesmus obliquus in semi-continuous cultivation outdoors for biodiesel feedstock production  

Science Journals Connector (OSTI)

Abstract In an effort to identify suitable microalgal species for biodiesel production, seven species were isolated from various habitats and their growth characteristics were compared. The results demonstrated that a green alga Scenedesmus obliquus could grow more rapidly and synthesize more lipids than other six microalgal strains. S. obliquus grew well both indoors and outdoors, and reached higher ?max indoors than that outdoors. However, the cells achieved higher dry weight (4.36 g L?1), lipid content (49.6%) and productivity (183 mg L?1 day?1) outdoors than in indoor cultures. During the 61 days semi-continuous cultivation outdoors, high biomass productivities (450–550 mg L?1 day?1) and ?max (1.05–1.44 day?1) were obtained. The cells could also achieve high lipid productivities (151–193 mg L?1 day?1). These results indicated that S. obliquus was promising for lipids production in semi-continuous cultivation outdoors.

Pingzhong Feng; Kang Yang; Zhongbin Xu; Zhongming Wang; Lu Fan; Lei Qin; Shunni Zhu; Changhua Shang; Peng Chai; Zhenhong Yuan; Lei Hu

2014-01-01T23:59:59.000Z

314

Factors affecting the indoor concentrations of carbonaceous aerosols of outdoor origin  

SciTech Connect

A field study was conducted in an unoccupied single story residence in Clovis, California to provide data to address issues important to assess the indoor exposure to particles of outdoor origin. Measurements of black and organic carbonaceous aerosols were performed using a variety of methods, resulting in both near real-time measurements as well as integrated filter based measurements. Comparisons of the different measurement methods show that it is crucial to account for gas phase adsorption artifacts when measuring organic carbon (OC). Measured concentrations affected by the emissions of organic compounds sorbed to indoor surfaces imply a higher degree of infiltration of outdoor organic carbon aerosols into the indoor environment for our unoccupied house. Analysis of the indoor and outdoor data for black carbon (BC) aerosols show that, on average, the indoor concentration of black carbon aerosols behaves in a similar manner to sulfate aerosols. In contrast, organic carbon aerosols are subject to chemical transformations indoors that, for our unoccupied home, resulted in lower indoor OC concentrations than would be expected by physical loss mechanisms alone. These results show that gas to particle partitioning of organic compounds, as well as gas to surface interactions within the residence, are an important process governing the indoor concentration to OC aerosols of outdoor origin.

Lunden, Melissa M.; Kirchstetter, Thomas W.; Thatcher, Tracy L.; Hering, Susanne V.; Brown, Nancy J.

2007-06-25T23:59:59.000Z

315

RIS-M-2234 A NOTE ON THE RELATIONSHIP BETWEEN OUTDOOR AND INDOOR  

E-Print Network (OSTI)

POLLUTION OP OUTDOOR ORIGIN H.L. Gjørup and Jørn Roed Health Physics Department Abstract. Beryllium-7-descriotors; AIR POLLUTION, BERYLLIUM 7, BUILDINGS, INHALATION, IODINE 131, MEASURING METHODS, RADIATION DOSES from its counterpart in Danish dated Hay 1979. 2. GENERAL INFORMATION Any pollution of inhaled air

316

Positioning by Tree Detection Sensor and Dead Reckoning for Outdoor Navigation of a Mobile Robot  

E-Print Network (OSTI)

, it is dicult to navi- gate robot in the environment shown in Fig.1, which has no walls, no painted lines norPositioning by Tree Detection Sensor and Dead Reckoning for Outdoor Navigation of a Mobile Robot Shoichi MAEYAMA, Akihisa OHYA and Shin'ichi YUTA Intelligent Robot Laboratory, Institute of Information

Ohya, Akihisa

317

Reductions in Urban Outdoor Water Use as an Adaptation to Rising  

E-Print Network (OSTI)

Supplies in Southern California ENVIRONMENTAL AREA RESEARCH PIER Environmental Research www.energy and tree planting--are being used to evaluate both the effects on total outdoor water usage as well California Energy Commission PIER Program, Environmental Area Phone: 9163272201 Email: SPittigl@energy

318

Economic Value of Outdoor Recreation Activities in Iowa Daniel Otto, KristinTylka, and  

E-Print Network (OSTI)

Economic Value of Outdoor Recreation Activities in Iowa Daniel Otto, KristinTylka, and Susan Erickson Department of Economics Iowa State University Extension and Outreach Center for Agricultural Otto is a professor in the Department of Economics at Iowa State University, Kristin Tylka

Chen, Tsing-Chang "Mike"

319

Outdoor Scene Synthesis in the Infrared Range for Remote Sensing Applications  

E-Print Network (OSTI)

Outdoor Scene Synthesis in the Infrared Range for Remote Sensing Applications Thierry Poglio Eric under remote sensing applications, like meteorology, farming, or military information are concerned. Yet. The solar forcing leads to an increase in temperature, while heat transfer due to strong cold wind decreases

Boyer, Edmond

320

Application of the Transmission Line Matrix method for outdoor sound propagation modelling Part 2  

E-Print Network (OSTI)

Application of the Transmission Line Matrix method for outdoor sound propagation modelling ­ Part 2 propagation model. The time-domain acoustic model is based on the Transmission Line Matrix method. Its.apacoust.2013.07.015 #12;Part 1, the presentation and evaluation of the Transmission Line Matrix method showed

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

The effect of agrochemicals on indicator bacteria densities in outdoor mesocosmsemi_2287 3150..3158  

E-Print Network (OSTI)

The effect of agrochemicals on indicator bacteria densities in outdoor mesocosmsemi_2287 3150, including patho- gens. Agrochemicals may influence the survival of these microorganisms in water bodies were used to investigate the response of Escherichia coli and enterococci to agrochemicals. Replicate

Rohr, Jason

322

GRR/Section 14-HI-c - Underground Injection Control Permit | Open Energy  

Open Energy Info (EERE)

GRR/Section 14-HI-c - Underground Injection Control Permit GRR/Section 14-HI-c - Underground Injection Control Permit < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 14-HI-c - Underground Injection Control Permit 14HIC - UndergroundInjectionControlPermit (1).pdf Click to View Fullscreen Contact Agencies Hawaii Department of Health Safe Drinking Water Branch Regulations & Policies Hawaii Administrative Rules Title 11, Chapter 23 Triggers None specified Click "Edit With Form" above to add content 14HIC - UndergroundInjectionControlPermit (1).pdf 14HIC - UndergroundInjectionControlPermit (1).pdf Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Flowchart Narrative The developer must receive an Underground Injection Control Permit from the

323

Numerical Simulations of Leakage from Underground LPG Storage Caverns  

SciTech Connect

To secure a stable supply of petroleum gas, underground storage caverns for liquified petroleum gas (LPG) are commonly used in many countries worldwide. Storing LPG in underground caverns requires that the surrounding rock mass remain saturated with groundwater and that the water pressure be higher than the liquid pressure inside the cavern. In previous studies, gas containment criteria for underground gas storage based on hydraulic gradient and pressure have been discussed, but these studies do not consider the physicochemical characteristics and behavior of LPG such as vaporization and dissolution in groundwater. Therefore, while these studies are very useful for designing storage caverns, they do not provide better understanding of the either the environmental effects of gas contamination or the behavior of vaporized LPG. In this study, we have performed three-phase fluid flow simulations of gas leakage from underground LPG storage caverns, using the multiphase multicomponent nonisothermal simulator TMVOC (Pruess and Battistelli, 2002), which is capable of solving the three-phase nonisothermal flow of water, gas, and a multicomponent mixture of volatile organic chemicals (VOCs) in multidimensional heterogeneous porous media. A two-dimensional cross-sectional model resembling an actual underground LPG facility in Japan was developed, and gas leakage phenomena were simulated for three different permeability models: (1) a homogeneous model, (2) a single-fault model, and (3) a heterogeneous model. In addition, the behavior of stored LPG was studied for the special case of a water curtain suddenly losing its function because of operational problems, or because of long-term effects such as clogging of boreholes. The results of the study indicate the following: (1) The water curtain system is a very powerful means for preventing gas leakage from underground storage facilities. By operating with appropriate pressure and layout, gas containment can be ensured. (2) However , in highly heterogeneous media such as fractured rock and fault zones, local flow paths within which the gas containment criterion is not satisfied could be formed. To eliminate such zones, treatments such as pre/post grouting or an additional installment of water-curtain boreholes are essential. (3) Along highly conductive features such as faults, even partially saturated zones possess certain effects that can retard or prevent gas leakage, while a fully unsaturated fault connected to the storage cavern can quickly cause a gas blowout. This possibility strongly suggests that ensuring water saturation of the rock surrounding the cavern is a very important requirement. (4) Even if an accident should suddenly impair the water curtain, the gas plume does not quickly penetrate the ground surface. In these simulations, the plume takes several months to reach the ground surface.

Yamamoto, Hajime; Pruess, Karsten

2004-09-01T23:59:59.000Z

324

Oconee Electric Member Corp | Open Energy Information  

Open Energy Info (EERE)

Oconee Electric Member Corp Oconee Electric Member Corp Jump to: navigation, search Name Oconee Electric Member Corp Place Georgia Utility Id 13962 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service Commercial Large Power Service Commercial Large Power Service* Industrial Outdoor Lighting MV 175 W Overhead Lighting Outdoor Lighting MV 175 W Underground Lighting Outdoor Lighting S 100 W Overhead Lighting Outdoor Lighting S 100 W Underground Lighting Residential and Farm Service Residential

325

Snapping Shoals El Member Corp | Open Energy Information  

Open Energy Info (EERE)

Snapping Shoals El Member Corp Snapping Shoals El Member Corp Jump to: navigation, search Name Snapping Shoals El Member Corp Place Georgia Utility Id 17832 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Outdoor Lighting Overhaed No Existing Pole HPS 100 W Lighting Outdoor Lighting Overhead Exisiting Pole HPS 100 W Lighting Outdoor Lighting Underground HPS 150 W Lighting Outdoor Lighting Underground HPS 70 W Lighting Residential Electric Rate Residential

326

Department of Energy Announces 15 Projects Aimed at Secure Underground  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

15 Projects Aimed at Secure 15 Projects Aimed at Secure Underground Storage of CO2 Department of Energy Announces 15 Projects Aimed at Secure Underground Storage of CO2 August 11, 2010 - 1:00pm Addthis Washington, DC - U.S. Energy Secretary Steven Chu announced today the selection of 15 projects to develop technologies aimed at safely and economically storing carbon dioxide (CO2) in geologic formations. Funded at $21.3 million over three years, today's selections will complement existing DOE initiatives to help develop the technology and infrastructure to implement large-scale CO2 storage in different geologic formations across the Nation. The projects selected today will support the goals of helping reduce U.S. greenhouse gas emissions, developing and deploying near-zero-emission coal technologies, and making the U.S. a leader in

327

Underground Natural Gas Working Storage Capacity - Energy Information  

Gasoline and Diesel Fuel Update (EIA)

Underground Natural Gas Working Storage Capacity Underground Natural Gas Working Storage Capacity With Data for November 2012 | Release Date: July 24, 2013 | Next Release Date: Spring 2014 Previous Issues Year: 2013 2012 2011 2010 2009 2008 2007 2006 Go Overview Natural gas working storage capacity increased by about 2 percent in the Lower 48 states between November 2011 and November 2012. The U.S. Energy Information Administration (EIA) has two measures of working gas storage capacity, and both increased by similar amounts: Demonstrated maximum volume increased 1.8 percent to 4,265 billion cubic feet (Bcf) Design capacity increased 2.0 percent to 4,575 Bcf Maximum demonstrated working gas volume is an operational measure of the highest level of working gas reported at each storage facility at any time

328

one mile underground into a deep saline formation. The injection  

NLE Websites -- All DOE Office Websites (Extended Search)

mile underground into a deep saline formation. The injection, mile underground into a deep saline formation. The injection, which will occur over a three-year period and is slated to start in early 2010, will compress up to 1 million metric tonnes of CO 2 from the ADM ethanol facility into a liquid-like, dense phase. The targeted rock formation, the Mt. Simon Sandstone, is the thickest and most widespread saline reservoir in the Illinois Basin, with an estimated CO 2 storage capacity of 27 to 109 billion metric tonnes. A comprehensive monitoring program, which will be evaluated yearly, will be implemented after the injection to ensure the injected CO 2 is stored safely and permanently. The RCSP Program was launched by the Office of Fossil Energy (FE)

329

Westinghouse Earns Mine Safety Award for Exceptional Underground Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Westinghouse Earns Mine Safety Award Westinghouse Earns Mine Safety Award For Exceptional Underground Operations CARLSBAD, N.M., October 5, 2000 - For the 14 th consecutive year, the Westinghouse Waste Isolation Division (WID) has been recognized for "excellence in underground operations" at the U.S. Department of Energy's (DOE) Waste Isolation Pilot Plant (WIPP). On September 19, New Mexico State Inspector of Mines Gilbert Miera and the New Mexico Mining Association presented Westinghouse with the "Mine Operator of the Year" award. The presentation took place at the New Mexico Mining Association's annual convention in Farmington. The "Mine Operator of the Year" award recognizes Westinghouse's close attention to safety in a mining environment. WID received the award in the category of "non-producing

330

Advanced Underground Gas Storage Concepts Refrigerated-Mined Cavern Storage  

NLE Websites -- All DOE Office Websites (Extended Search)

UNDERGROUND GAS STORAGE CONCEPTS UNDERGROUND GAS STORAGE CONCEPTS REFRIGERATED-MINED CAVERN STORAGE FINAL REPORT DOE CONTRACT NUMBER DE-AC26-97FT34349 SUBMITTED BY: PB-KBB INC. 11757 KATY FREEWAY, SUITE 600 HOUSTON, TX 77079 SEPTEMBER 1998 Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily

331

Underground coal gasification: a brief review of current status  

SciTech Connect

Coal gasification is a promising option for the future use of coal. Similarly to gasification in industrial reactors, underground coal gasification (UCG) produces syngas, which can be used for power generation or for the production of liquid hydrocarbon fuels and other valuable chemical products. As compared with conventional mining and surface gasification, UCG promises lower capital/operating costs and also has other advantages, such as no human labor underground. In addition, UCG has the potential to be linked with carbon capture and sequestration. The increasing demand for energy, depletion of oil and gas resources, and threat of global climate change lead to growing interest in UCG throughout the world. In this article, we review the current status of this technology, focusing on recent developments in various countries.

Shafirovich, E.; Varma, A. [Purdue University, West Lafayette, IN (United States). School of Chemical Engineering

2009-09-15T23:59:59.000Z

332

DIANA - A deep underground accelerator for nuclear astrophysics experiments  

SciTech Connect

DIANA (Dakota Ion Accelerator for Nuclear Astrophysics) is a proposed facility designed to be operated deep underground. The DIANA collaboration includes nuclear astrophysics groups from Lawrence Berkeley National Laboratory, Michigan State University, Western Michigan University, Colorado School of Mines, and the University of North Carolina, and is led by the University of Notre Dame. The scientific goals of the facility are measurements of low energy nuclear cross-sections associated with sun and pre-supernova stars in a laboratory setup at energies that are close to those in stars. Because of the low stellar temperatures associated with these environments, and the high Coulomb barrier, the reaction cross-sections are extremely low. Therefore these measurements are hampered by small signal to background ratios. By going underground the background due to cosmic rays can be reduced by several orders of magnitude. We report on the design status of the DIANA facility with focus on the 3 MV electrostatic accelerator.

Winklehner, Daniel; Leitner, Daniela [Michigan State University, 640 S Shaw Lane, East Lansing MI 48824 (United States); Lemut, Alberto; Hodgkinson, Adrian [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley CA 94720 (United States); Couder, Manoel; Wiescher, Michael [University of Notre Dame, Notre Dame, IN 46556 (United States)

2013-04-19T23:59:59.000Z

333

200-Area plateau inactive miscellaneous underground storage tanks locations  

SciTech Connect

Fluor Daniel Northwest (FDNW) has been tasked by Lockheed Martin Hanford Corporation (LMHC) to incorporate current location data for 64 of the 200-Area plateau inactive miscellaneous underground storage tanks (IMUST) into the centralized mapping computer database for the Hanford facilities. The IMUST coordinate locations and tank names for the tanks currently assigned to the Hanford Site contractors are listed in Appendix A. The IMUST are inactive tanks installed in underground vaults or buried directly in the ground within the 200-East and 200-West Areas of the Hanford Site. The tanks are categorized as tanks with a capacity of less than 190,000 liters (50,000 gal). Some of the IMUST have been stabilized, pumped dry, filled with grout, or may contain an inventory or radioactive and/or hazardous materials. The IMUST have been out of service for at least 12 years.

Brevick, C.H.

1997-12-01T23:59:59.000Z

334

depleted underground oil shale for the permanent storage of carbon  

NLE Websites -- All DOE Office Websites (Extended Search)

depleted underground oil shale for the permanent storage of carbon depleted underground oil shale for the permanent storage of carbon dioxide (CO 2 ) generated during the oil shale extraction process. AMSO, which holds a research, development, and demonstration (RD&D) lease from the U.S. Bureau of Land Management for a 160-acre parcel of Federal land in northwest Colorado's oil-shale rich Piceance Basin, will provide technical assistance and oil shale core samples. If AMSO can demonstrate an economically viable and environmentally acceptable extraction process, it retains the right to acquire a 5,120-acre commercial lease. When subject to high temperatures and high pressures, oil shale (a sedimentary rock that is rich in hydrocarbons) can be converted into oil. Through mineralization, the CO 2 could be stored in the shale

335

Underground Injection Control Fee Schedule (West Virginia) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Injection Control Fee Schedule (West Virginia) Injection Control Fee Schedule (West Virginia) Underground Injection Control Fee Schedule (West Virginia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State West Virginia Program Type Fees Provider Department of Environmental Protection This rule establishes schedules of permit fees for state under-ground injection control permits issued by the Chief of the Office of Water Resources. This rule applies to any person who is required to apply for and

336

Methodology for EIA Weekly Underground Natural Gas Storage Estimates  

Weekly Natural Gas Storage Report (EIA)

Methodology for EIA Weekly Underground Natural Gas Storage Estimates Methodology for EIA Weekly Underground Natural Gas Storage Estimates Latest Update: November 25, 2008 This report consists of the following sections: Survey and Survey Processing - a description of the survey and an overview of the program Sampling - a description of the selection process used to identify companies in the survey Estimation - how the regional estimates are prepared from the collected data Computing the 5-year Averages, Maxima, Minima, and Year-Ago Values for the Weekly Natural Gas Storage Report - the method used to prepare weekly data to compute the 5-year averages, maxima, minima, and year-ago values for the weekly report Derivation of the Weekly Historical Estimates Database - a description of the process used to generate the historical database for the

337

Rating underground pipeline tape and shrink sleeve coating systems  

SciTech Connect

A rating system was developed for several coating types used for underground pipeline systems. Consideration included soil stress, adhesion, surface preparation, cathodic protection (CP) shielding, CP requirements, handling and construction, repair, field joint system, bends and other components, and the application process. Polyethylene- and polyvinyl chloride-backed tapes, woven polyolefin geotextile fabric (WGF)-backed tapes, hot-applied tapes, petrolatum- and wax-based tapes, and shrink sleeves were evaluated. WGF-backed tapes had the highest rating.

Norsworthy, R.

1999-11-01T23:59:59.000Z

338

Building a predictive model of indoor concentrations of outdoor PM-2.5 for  

NLE Websites -- All DOE Office Websites (Extended Search)

Building a predictive model of indoor concentrations of outdoor PM-2.5 for Building a predictive model of indoor concentrations of outdoor PM-2.5 for a residential research house in Clovis, California Title Building a predictive model of indoor concentrations of outdoor PM-2.5 for a residential research house in Clovis, California Publication Type Report Year of Publication 2002 Authors Fischer, Marc L., Melissa M. Lunden, Tracy L. Thatcher, David Littlejohn, Thomas W. Kirchstetter, Susanne V. Hering, Richard G. Sextro, and Nancy J. Brown Abstract The prevalence of relocatable classrooms (RCs) at schools is rising due to federal and state initiatives to reduce K-3 class size, and limited capital resources. Concerns regarding inadequate ventilation and indoor air and environmental quality (IEQ) in RCs have been raised. Adequate ventilation is an important link between improved IEQ and energy efficiency for schools. Since students and teachers spend the majority of a 7-8 hour school day inside classrooms, indoor contaminant concentrations are assumed to drive personal school-day exposures. We conducted a demonstration project in new relocatable classrooms (RCs) during the 2001-02 school year to address these issues. Four new 24' x 40' (960 ft2) RCs were constructed and sited in pairs at an elementary school campus in each of two participant school districts (SD) in Northern California. Each RC was equipped with two heating, ventilation, and air conditioning (HVAC) systems, one per module. The two HVAC systems were a standard heat pump with intermittent 25-50% outdoor air ventilation and an energy-efficient advanced system, based on indirect-direct evaporative cooling with an integrated natural gas-fired hydronic heating loop and improved particle filtration, providing continuous 100% outdoor air ventilation at = 15 ft3 min-1 occupant-1. Alternate carpets, wall panels, and ceiling panels were installed in two classrooms -- one in each pair -- based on the results of a laboratory study of VOC emissions from standard and alternate materials. Numerous IEQ and outdoor air quality and meteorological parameters were measured either continuously over the school year or as integrated school day samples during the fall cooling and winter heating seasons. Details of the RC designs, the field monitoring methodology including handling, storage, transport and management of chemical samples and data, and analyses to be conducted are presented

339

Iowa Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Iowa Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 228,019 220,410 215,229 215,377 219,838 224,572 230,226 236,154 239,871 243,782 241,829 227,519 1991 225,964 215,495 211,852 213,588 218,084 228,720 234,297 240,868 252,335 263,855 255,740 241,570 1992 221,741 209,087 205,548 208,105 217,022 225,236 236,833 247,704 258,372 267,472 258,308 237,797 1993 218,826 208,027 205,378 210,868 217,693 225,793 236,688 247,032 259,649 265,238 258,580 240,957 1994 222,694 213,205 210,208 212,114 217,678 224,185 234,433 245,426 257,120 266,215 261,645 243,875 1995 223,356 212,480 208,011 207,340 211,295 219,417 229,558 244,448 256,135 263,260 252,590 237,557

340

Utah Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Utah Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 59,806 56,937 55,229 54,606 57,328 55,249 67,314 75,921 83,365 86,778 66,668 58,461 1991 61,574 54,369 50,745 51,761 54,314 60,156 66,484 70,498 74,646 75,367 70,399 63,453 1992 59,541 59,119 59,059 60,896 64,403 67,171 70,690 75,362 78,483 79,756 74,021 67,181 1993 61,308 56,251 52,595 52,028 58,713 65,349 69,968 75,120 80,183 85,406 79,818 75,184 1994 70,826 63,733 66,678 68,028 74,061 78,089 83,551 89,773 98,223 102,035 99,841 94,306 1995 86,450 83,059 79,507 80,647 84,154 90,012 97,005 100,430 101,993 102,510 103,779 93,925

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

New York Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) New York Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 124,150 116,994 113,349 121,215 131,103 139,757 148,861 155,592 158,419 160,981 150,947 1991 127,051 118,721 114,190 117,571 124,275 132,029 140,317 149,058 157,799 163,054 158,736 151,036 1992 146,171 131,831 119,880 122,969 132,698 142,107 153,543 163,508 169,298 172,708 169,361 158,828 1993 145,521 129,184 118,756 122,771 133,838 144,835 154,895 162,969 172,642 174,589 171,253 161,801 1994 143,310 129,129 120,675 129,563 138,273 150,582 159,688 168,628 173,584 174,977 172,352 163,470 1995 149,768 135,478 129,570 130,077 138,659 150,010 156,744 165,026 173,947 175,635 165,945 148,196

342

Iowa Natural Gas Injections into Underground Storage (Million Cubic Feet)  

Gasoline and Diesel Fuel Update (EIA)

Injections into Underground Storage (Million Cubic Feet) Injections into Underground Storage (Million Cubic Feet) Iowa Natural Gas Injections into Underground Storage (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 1,740 243 1,516 3,236 5,817 8,184 5,657 5,928 4,903 4,971 1,423 854 1991 1,166 155 231 1,829 4,897 8,985 6,518 8,058 11,039 10,758 2,782 860 1992 488 43 1,246 3,184 7,652 7,568 11,453 11,281 11,472 9,000 1,228 1,203 1993 0 0 733 5,547 6,489 7,776 10,550 10,150 12,351 8,152 2,437 0 1994 0 75 1,162 3,601 7,153 7,638 11,999 12,405 13,449 10,767 2,678 0 1995 0 0 251 1,041 5,294 9,889 12,219 17,805 13,756 8,855 1,283 391 1996 2 2 0 40 1,921 7,679 12,393 13,168 12,537 10,556 2,760 0

343

Oklahoma Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Oklahoma Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 296,629 281,511 286,917 279,978 298,202 307,083 317,720 325,432 332,591 338,392 353,804 327,277 1991 283,982 278,961 284,515 298,730 313,114 323,305 324,150 328,823 338,810 342,711 317,072 306,300 1992 288,415 280,038 276,287 282,263 290,192 301,262 318,719 326,705 339,394 346,939 330,861 299,990 1993 275,054 253,724 246,989 257,844 277,833 296,860 311,870 325,201 341,207 348,646 330,986 316,146 1994 285,115 259,794 257,148 273,797 298,007 311,154 327,281 340,312 349,174 353,630 350,671 334,502 1995 310,835 297,169 287,302 291,768 308,245 320,842 327,910 326,131 338,685 351,385 343,918 320,269

344

Montana Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Montana Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 293,785 290,491 289,197 288,193 293,815 288,808 290,947 293,015 295,663 296,921 295,421 290,602 1991 289,270 287,858 286,548 286,491 287,718 288,959 290,667 292,107 292,226 290,844 288,112 284,559 1992 281,148 279,325 278,909 279,042 280,038 280,751 281,777 282,543 282,117 280,760 277,412 271,811 1993 266,711 262,291 259,532 257,822 256,665 255,940 257,149 257,450 257,904 257,816 253,710 250,503 1994 246,679 239,940 238,777 237,993 238,931 240,738 242,090 243,176 244,948 245,981 244,275 241,603 1995 238,103 236,109 235,420 236,218 237,498 239,637 242,554 245,760 246,856 246,301 243,255 238,004

345

AGA Western Consuming Region Natural Gas Underground Storage Volume  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) AGA Western Consuming Region Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1994 888,010 816,597 813,746 830,132 876,457 908,444 941,985 966,686 1,002,402 1,021,144 997,644 956,234 1995 902,782 884,830 865,309 860,012 897,991 945,183 975,307 986,131 1,011,948 1,032,357 1,033,363 982,781 1996 896,744 853,207 837,980 849,221 885,715 916,778 929,559 928,785 946,748 949,983 939,649 899,689 1997 833,239 796,139 788,601 801,955 844,880 890,703 923,845 947,277 969,170 980,388 967,286 880,627 1998 828,658 780,476 768,264 773,053 823,311 872,913 900,181 925,287 965,846 1,001,548 1,009,978 953,379

346

Indiana Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Indiana Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 96,943 93,233 91,600 91,945 93,696 95,361 97,632 101,323 105,497 108,028 108,772 105,317 1991 99,409 90,625 87,381 86,706 88,659 89,700 93,022 97,673 102,161 119,470 106,066 101,121 1992 94,379 89,893 85,767 85,259 86,457 88,999 94,154 98,267 103,478 106,422 103,871 100,288 1993 95,109 90,016 87,368 88,414 89,388 91,515 95,971 100,516 104,709 106,058 104,160 101,505 1994 95,846 92,274 90,200 89,473 89,417 91,870 97,002 101,310 105,300 109,518 110,149 107,215 1995 101,661 95,902 93,464 92,724 93,156 94,955 97,862 101,470 106,201 110,610 111,401 106,609

347

Illinois Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Illinois Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 806,109 754,941 721,785 717,863 749,618 782,498 812,054 847,731 881,760 900,526 903,640 870,265 1991 801,635 753,141 727,699 720,275 751,641 781,883 810,535 844,477 877,485 904,206 885,341 851,258 1992 791,129 743,484 716,909 709,150 742,812 774,578 805,097 843,543 878,334 905,597 887,454 844,108 1993 783,875 735,236 710,377 713,214 746,899 779,762 810,546 844,320 882,456 907,957 898,655 854,691 1994 781,826 737,719 723,108 722,735 746,576 776,189 808,832 843,372 880,762 907,622 898,872 866,846 1995 803,422 745,457 721,311 716,886 745,970 774,803 804,912 837,002 868,941 899,868 885,665 841,580

348

Ohio Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Ohio Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 439,384 418,280 409,494 412,498 435,089 454,844 474,266 493,301 510,714 521,774 518,006 489,515 1991 477,781 454,923 439,191 448,258 461,362 490,259 505,168 523,544 538,399 546,343 533,483 506,672 1992 463,200 428,363 392,474 394,514 420,383 452,412 478,259 500,938 516,378 527,568 522,419 491,542 1993 452,510 407,121 368,376 371,641 401,431 433,291 462,741 490,248 515,994 522,961 510,471 470,120 1994 413,475 378,216 361,279 377,103 406,526 438,293 471,603 498,156 519,996 530,505 526,490 498,597 1995 448,479 410,867 391,082 385,953 413,796 445,322 472,162 495,448 513,913 522,766 498,715 455,782

349

Kansas Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Kansas Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 245,145 234,971 229,066 227,002 227,589 232,695 244,279 256,395 272,036 278,715 307,106 283,959 1991 247,980 246,067 240,702 238,606 244,878 254,222 257,114 260,728 271,373 282,551 273,225 274,836 1992 267,254 254,115 244,632 239,589 241,818 244,415 248,599 260,231 270,362 273,183 262,414 247,855 1993 229,148 213,533 208,832 213,112 235,850 247,585 253,023 261,780 276,136 278,233 268,816 259,719 1994 243,371 229,217 228,379 229,034 240,066 245,355 256,229 268,820 278,655 283,143 276,402 266,198 1995 251,176 239,135 228,409 230,202 239,892 252,703 252,472 252,461 269,034 280,066 272,406 255,483

350

Kentucky Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Kentucky Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 167,899 166,624 167,576 172,320 177,680 185,467 192,473 199,674 202,983 198,545 192,581 1991 183,697 180,169 176,535 181,119 183,491 186,795 192,143 195,330 198,776 198,351 191,831 189,130 1992 189,866 188,587 183,694 182,008 180,781 182,342 185,893 187,501 191,689 202,391 200,871 197,857 1993 192,736 181,774 172,140 171,465 177,888 185,725 193,275 198,075 204,437 205,524 199,683 188,970 1994 170,283 157,974 153,378 158,141 167,847 177,200 186,856 193,717 197,308 200,665 200,993 192,700 1995 179,376 166,756 162,223 165,687 178,354 185,982 192,799 196,645 203,357 205,882 196,585 185,704

351

Salt Producing Region Natural Gas Working Underground Storage (Billion  

Gasoline and Diesel Fuel Update (EIA)

Salt Producing Region Natural Gas Working Underground Storage (Billion Cubic Feet) Salt Producing Region Natural Gas Working Underground Storage (Billion Cubic Feet) Salt Producing Region Natural Gas Working Underground Storage (Billion Cubic Feet) Year-Month Week 1 Week 2 Week 3 Week 4 Week 5 End Date Value End Date Value End Date Value End Date Value End Date Value 2006-Dec 12/29 101 2007-Jan 01/05 109 01/12 107 01/19 96 01/26 91 2007-Feb 02/02 78 02/09 63 02/16 52 02/23 54 2007-Mar 03/02 59 03/09 58 03/16 64 03/23 70 03/30 78 2007-Apr 04/06 81 04/13 80 04/20 80 04/27 83 2007-May 05/04 85 05/11 88 05/18 92 05/25 97 2007-Jun 06/01 100 06/08 101 06/15 102 06/22 102 06/29 102

352

AGA Eastern Consuming Region Natural Gas Injections into Underground  

Gasoline and Diesel Fuel Update (EIA)

Gas Injections into Underground Storage (Million Cubic Feet) Gas Injections into Underground Storage (Million Cubic Feet) AGA Eastern Consuming Region Natural Gas Injections into Underground Storage (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1994 7,862 17,834 34,190 160,946 247,849 262,039 269,285 244,910 208,853 134,234 47,094 16,471 1995 13,614 4,932 36,048 85,712 223,991 260,731 242,718 212,493 214,385 160,007 37,788 12,190 1996 12,276 39,022 32,753 130,232 233,717 285,798 303,416 270,223 247,897 166,356 39,330 28,875 1997 16,058 14,620 25,278 93,501 207,338 258,086 250,776 252,129 233,730 152,913 53,097 10,338 1998 21,908 13,334 48,068 139,412 254,837 234,427 234,269 207,026 178,129 144,203 52,518 28,342

353

Lower 48 States Natural Gas Working Underground Storage (Billion Cubic  

Gasoline and Diesel Fuel Update (EIA)

Lower 48 States Natural Gas Working Underground Storage (Billion Cubic Feet) Lower 48 States Natural Gas Working Underground Storage (Billion Cubic Feet) Lower 48 States Natural Gas Working Underground Storage (Billion Cubic Feet) Year-Month Week 1 Week 2 Week 3 Week 4 Week 5 End Date Value End Date Value End Date Value End Date Value End Date Value 1993-Dec 12/31 2,322 1994-Jan 01/07 2,186 01/14 2,019 01/21 1,782 01/28 1,662 1994-Feb 02/04 1,470 02/11 1,303 02/18 1,203 02/25 1,149 1994-Mar 03/04 1,015 03/11 1,004 03/18 952 03/25 965 1994-Apr 04/01 953 04/08 969 04/15 1,005 04/22 1,085 04/29 1,161 1994-May 05/06 1,237 05/13 1,325 05/20 1,403 05/27 1,494

354

Mississippi Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Mississippi Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 79,285 79,603 80,373 85,161 89,985 93,156 99,475 104,348 108,323 111,705 112,191 106,545 1991 91,368 86,763 86,679 92,641 96,297 98,701 100,991 103,104 108,211 112,270 104,184 98,741 1992 89,008 87,873 85,498 85,665 89,979 94,898 99,555 100,116 106,504 107,770 107,015 100,433 1993 94,466 86,908 80,802 83,305 90,316 94,786 99,933 103,264 109,076 109,790 108,869 101,774 1994 92,881 89,305 92,689 97,058 101,796 102,770 109,298 114,566 116,697 120,326 121,207 115,933 1995 107,126 102,620 98,569 103,285 110,250 111,888 116,039 116,791 123,081 125,717 116,280 109,906

355

Texas Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Texas Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 456,385 449,625 443,662 508,009 518,658 531,197 544,212 538,450 539,191 556,768 562,961 526,092 1991 444,671 436,508 436,440 453,634 468,302 487,953 491,758 497,878 513,315 517,099 502,004 486,831 1992 455,054 440,895 435,515 438,408 456,948 469,532 491,515 508,950 511,787 516,598 496,232 459,458 1993 414,216 388,921 376,731 396,804 423,544 444,755 453,961 466,560 450,853 457,581 445,059 431,719 1994 381,924 342,046 350,039 374,226 407,219 419,997 446,215 462,725 485,146 495,417 500,640 478,036 1995 465,108 443,908 434,564 455,756 479,313 497,829 498,982 490,940 510,646 520,173 509,944 463,202

356

Colorado Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Colorado Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 66,554 61,757 56,567 52,684 52,375 56,614 62,829 68,028 73,035 74,259 80,053 1991 71,524 69,768 62,807 61,367 62,448 66,425 70,705 75,800 80,506 82,065 83,134 82,145 1992 78,319 74,888 68,199 64,030 63,685 65,682 69,830 76,095 82,007 84,134 81,041 78,303 1993 73,838 68,733 66,224 62,799 65,511 70,157 73,322 77,155 81,457 81,981 79,475 78,303 1994 72,798 67,880 65,147 60,034 65,538 67,050 71,639 76,943 82,093 82,347 80,736 77,356 1995 73,047 69,545 64,567 59,852 62,142 70,945 73,047 77,326 80,150 81,357 82,831 77,475

357

Maryland Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Maryland Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 50,980 47,820 48,924 49,656 52,214 53,271 55,370 58,030 60,465 61,702 59,577 58,586 1991 55,450 52,159 50,537 51,458 52,941 54,594 55,998 58,233 60,342 61,017 61,304 61,207 1992 56,350 51,413 48,752 47,855 51,162 53,850 55,670 58,057 60,123 61,373 61,882 59,775 1993 56,503 52,155 50,240 49,746 51,939 53,114 54,206 55,924 58,423 61,103 61,504 58,605 1994 52,059 49,590 50,127 51,375 53,420 54,885 56,985 58,443 59,992 61,761 60,987 59,854 1995 57,642 53,398 53,293 53,049 55,049 57,080 56,891 58,074 60,121 61,273 60,740 57,798

358

Arkansas Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Arkansas Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 27,878 27,848 27,810 27,846 27,946 28,419 28,946 29,427 29,707 29,734 29,656 29,429 1991 27,498 27,132 26,811 26,616 26,747 27,086 27,573 27,587 27,587 27,587 26,958 26,294 1992 25,642 25,124 24,681 24,523 24,507 25,016 25,868 26,532 26,966 26,770 26,404 25,781 1993 25,148 24,276 23,798 23,676 22,852 22,866 22,856 22,856 22,856 22,731 22,096 21,239 1994 19,771 18,729 17,426 17,116 17,647 18,199 18,762 19,566 19,776 19,712 19,354 18,757 1995 17,752 16,999 16,460 16,330 16,541 17,854 19,348 20,738 20,895 20,815 20,197 18,048

359

Pennsylvania Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Pennsylvania Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 516,257 477,783 453,124 462,399 511,406 619,401 671,431 711,942 717,828 719,002 665,421 1991 543,808 501,265 471,608 482,628 527,550 545,866 569,927 607,093 651,148 669,612 658,358 627,857 1992 559,416 497,895 441,187 445,158 485,227 535,829 579,713 622,943 665,414 690,920 692,280 650,707 1993 580,189 479,149 417,953 444,095 494,680 547,289 592,762 632,195 680,452 695,718 689,050 639,761 1994 532,216 455,494 434,081 475,107 527,242 583,595 634,007 677,221 700,758 716,066 696,721 656,431 1995 590,100 497,162 469,515 481,690 525,118 578,640 611,291 648,080 695,988 713,882 669,744 594,750

360

Eastern Consuming Region Natural Gas Working Underground Storage (Billion  

Gasoline and Diesel Fuel Update (EIA)

Eastern Consuming Region Natural Gas Working Underground Storage (Billion Cubic Feet) Eastern Consuming Region Natural Gas Working Underground Storage (Billion Cubic Feet) Eastern Consuming Region Natural Gas Working Underground Storage (Billion Cubic Feet) Year-Month Week 1 Week 2 Week 3 Week 4 Week 5 End Date Value End Date Value End Date Value End Date Value End Date Value 1993-Dec 12/31 1,411 1994-Jan 01/07 1,323 01/14 1,199 01/21 1,040 01/28 958 1994-Feb 02/04 838 02/11 728 02/18 665 02/25 627 1994-Mar 03/04 529 03/11 531 03/18 462 03/25 461 1994-Apr 04/01 465 04/08 475 04/15 494 04/22 541 04/29 593 1994-May 05/06 636 05/13 690 05/20 731 05/27 795

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Louisiana Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Louisiana Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 377,554 379,627 371,519 372,188 379,245 393,418 407,240 421,000 435,705 450,886 459,955 452,883 1991 405,740 373,892 361,085 367,797 387,769 411,591 425,349 435,719 453,303 477,425 464,906 433,184 1992 387,456 358,639 345,049 348,097 369,129 388,728 403,713 413,375 432,171 452,989 447,115 411,919 1993 365,128 321,651 298,841 302,181 340,366 375,731 402,638 430,431 466,345 481,609 468,227 421,634 1994 376,035 357,247 343,892 365,948 400,035 421,714 451,504 474,085 497,428 506,525 502,477 463,847 1995 412,075 372,991 364,320 374,312 392,968 420,738 441,510 442,655 466,060 480,119 455,669 408,882

362

California Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) California Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 369,842 350,519 355,192 376,146 401,513 414,633 418,894 421,696 426,235 440,326 397,785 1991 376,267 376,879 359,926 380,826 407,514 431,831 445,387 448,286 448,383 448,081 441,485 417,177 1992 374,166 357,388 341,665 355,718 382,516 404,547 418,501 431,069 445,438 455,642 446,085 390,868 1993 357,095 337,817 348,097 356,320 385,972 399,994 423,027 433,552 448,573 461,473 446,120 411,943 1994 372,605 328,438 327,546 346,463 374,574 394,821 412,465 421,818 438,754 450,997 434,260 408,636 1995 377,660 373,010 365,068 362,271 388,641 414,650 428,646 426,927 442,131 460,286 462,316 436,346

363

Tennessee Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Tennessee Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1997 0 0 0 0 0 0 0 0 0 0 0 0 1998 799 683 623 539 539 539 673 807 919 1,022 1,126 1,127 1999 996 872 741 661 658 802 909 985 1,089 1,194 1,251 1,195 2000 1,031 855 792 729 711 711 711 711 711 760 874 959 2001 963 903 830 761 865 978 1,009 1,072 1,118 1,180 938 937 2002 987 988 990 990 965 962 949 945 942 940 852 852 2003 744 634 566 519 554 630 705 800 803 848 848 787 2004 684 633 621 652 685 731 794 849 854 879 867 826 2005 784 704 605 524 483 466 466 466 428 419 413 400

364

Nebraska Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Nebraska Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 82,538 81,491 81,181 82,095 83,472 85,002 83,477 83,923 85,020 84,918 81,317 1991 79,407 78,372 77,653 78,788 81,843 83,985 83,721 83,657 84,562 84,253 83,847 81,475 1992 79,888 78,880 78,837 79,448 81,080 83,708 85,758 86,968 88,154 87,853 85,260 81,824 1993 78,414 76,448 75,412 76,380 79,328 82,649 85,226 87,084 88,593 88,564 86,793 84,418 1994 81,833 79,100 79,242 80,202 82,339 83,239 85,362 85,709 87,835 88,765 88,935 86,932 1995 84,820 83,825 82,895 82,697 83,340 84,206 35,388 35,566 35,950 35,183 33,585 31,992

365

Light Portal  

Science Journals Connector (OSTI)

The Light Portal was designed to organize and mark the pedestrian paths that circumnavigate the rectangle of the...

2006-01-01T23:59:59.000Z

366

Light's twist  

Science Journals Connector (OSTI)

...equal to the optical power divided by the speed of light, and hence go unnoticed in our everyday lives...approaching object equal to the power in the light beam (P) divided by the speed of light. The movement of the approaching object does...

2014-01-01T23:59:59.000Z

367

Light Properties Light travels at the speed of light `c'  

E-Print Network (OSTI)

LIGHT!! #12;Light Properties Light travels at the speed of light `c' C = 3 x 108 m/s Or 190.nasa.gov #12;The speed of light The speed of light `c' is equal to the frequency ` times the wavelength,000 miles/second!! Light could travel around the world about 8 times in one second #12;What is light?? Light

Mojzsis, Stephen J.

368

GOING UNDERGROUND IN FINLAND: DESIGN OF ONKALO IN PROGRESS  

SciTech Connect

The long-term program aimed at selection of a site for a deep repository was initiated in Finland in 1983. This program has come to end in 2001 and a new phase aimed at implementation of the geological disposal of spent fuel has been started. In this new phase the first milestone is the application for a construction license for the disposal facility around 2010. To fulfill the needs for detailed design of the disposal system, an underground rock characterization facility (URCF) will be constructed at the representative depth at Olkiluoto. The excavation of this facility will start the work for underground characterization, testing and demonstration, which is planned to be a continuous activity throughout the whole life cycle of the deep repository. The overall objectives for the underground site characterization are (1) verification of the present conclusions on site suitability, (2) definition and identification of suitable rock volumes for repository space and (3) characterization of planned host rock for detailed design, safety assessment and construction planning. The objective for verification aims at assessing that the Olkiluoto site meets the basic criteria for long-term safety and as well the basic requirements for construction and thus justifies the site selection. The two other main objectives are closely related to design of the repository and assessing the long-term safety of the site-specific disposal system. The most important objective of ONKALO should allow an in-depth investigation of the geological environment and to provide the opportunity to allow validation of models at more appropriate scales and conditions than can be achieved from the surface. In some areas, such as in demonstrating operational safety, in acquiring geological information at a repository scale and in constructional and operational feasibility, the ONKALO will provide the only reliable source of in situ data. The depth range envisaged for URCF called ONKALO is between 400 and 600 m. The location and underground geometry of access ramp is of significance. Development of ONKALO will begin in 2003 and it consists of surface facilities, access ramp and vertical shaft to the depth of 500 meters and characterization and demonstration facilities. Total volume of the ONKALO underground facilities is approximately 250 000 m3. The development will be completed around 2010. The reconciliation of construction and investigations plays an important role through the project. Other major issues will be the management of groundwater conditions, workplace safety and documentation of the work.

Dikds, T.; Ikonen, A.; Niiranen, S.; Hansen, J.

2003-02-27T23:59:59.000Z

369

Factors affecting the indoor concentrations of carbonaceous aerosols of outdoor origin  

NLE Websites -- All DOE Office Websites (Extended Search)

Factors affecting the indoor concentrations of carbonaceous aerosols of Factors affecting the indoor concentrations of carbonaceous aerosols of outdoor origin Melissa M. Lunden 1 ∗ , Thomas W. Kirchstetter 1 , Tracy L. Thatcher 2 , Susanne V. Hering 3 , and Nancy J. Brown 1 1 Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd., Berkeley, CA 94720, USA 2 Department of Civil and Environmental Engineering, California Polytechnic State University, San Luis Obispo, CA 93407, USA 2 Aerosol Dynamics Inc., 2329 4th Street, Berkeley, CA 94710, USA Abstract A field study was conducted in an unoccupied single story residence in Clovis, California to provide data to address issues important to assess the indoor exposure to particles of outdoor origin. Measurements of black and organic carbonaceous aerosols were performed using a

370

Outdoor Performance of a Thin-Film Gallium-Arsenide Photovoltaic Module  

SciTech Connect

We deployed a 855 cm2 thin-film, single-junction gallium arsenide (GaAs) photovoltaic (PV) module outdoors. Due to its fundamentally different cell technology compared to silicon (Si), the module responds differently to outdoor conditions. On average during the test, the GaAs module produced more power when its temperature was higher. We show that its maximum-power temperature coefficient, while actually negative, is several times smaller in magnitude than that of a Si module used for comparison. The positive correlation of power with temperature in GaAs is due to temperature-correlated changes in the incident spectrum. We show that a simple correction based on precipitable water vapor (PWV) brings the photocurrent temperature coefficient into agreement with that measured by other methods and predicted by theory. The low operating temperature and small temperature coefficient of GaAs give it an energy production advantage in warm weather.

Silverman, T. J.; Deceglie, M. G.; Marion, B.; Cowley, S.; Kayes, B.; Kurtz, S.

2013-06-01T23:59:59.000Z

371

A plan for teaching waste management education at an outdoor education center  

E-Print Network (OSTI)

A PLAN FOR TEACHING WASTE MANAGEMENT EDUCATION AT AN OUTDOOR EDUCATION CENTER A PROFESSIONAL PAPER BY JOE DON ARMSTRONG Submitted to the College of Agriculture and Life Sciences of Texas A&M University in partial fulfillment... by JOE DON ARMSTRONG Approved as to style and content by: DR, LOUIS H DGES (CHAIRMAN OF ADVISORY COMMITTEE) DR. EDWARD HEATH (COMMITTEE MEMBER) DR. CAMILL G (COMMITTEE MBER) DR. R WITT (DEPARTMENT HEAD) MAY 1994 1 1. l. ABSTRACT A Plan...

Armstrong, Joe Don

1994-01-01T23:59:59.000Z

372

Monitoring and simulation of the thermal performance of solar heated outdoor swimming pools  

SciTech Connect

Based on detailed measurements of two outdoor swimming pools (at Leonberg and Moehringen) a computer model has been developed and validated for the simulation of the thermal behaviour of such pools. The subroutine is compatible to TRNSYS 13.1. Correlations for the heat losses due to evaporation, convection, and radiation were taken from literature and tested in the model. It was not possible to select one optimal correlation for the description of the evaporative heat losses of both swimming pools due to the different exposure to wind. Using the most suitable correlation for the evaporative heat losses of each pool allowed for the simulation of the pool temperature with less than 0.5 K standard deviation between measured and simulated temperature. the major problem was the measurement of the relevant wind speed to be used in the correlations describing the evaporative heat losses under real outdoor conditions. A method is described detailing how to calibrate the model using the heating energy requirement and the measured pool temperature during actual operation periods. The analysis of the measured data of two different outdoor swimming pools under the same climatic conditions showed differences of a factor 2 and more in the heat demand per unit pool area. This was mainly caused by the difference in local wind speed which differed by more than a factor 4. The two pools investigated were heated by solar energy with a fraction of 28% and 14%, respectively, and the seasonal efficiency of the solar systems was 37.7% and 33.4%. Simulations show that a reduction of the water temperature from 24[degrees]C to 22[degrees]C during periods with low outdoor temperatures and few visitors, reduces the fuel consumption to less than half and increases the solar fraction from 28% to 50% in one pool.

Hahne, E.; Kuebler, R. (Universitaet Stuttgart (Germany))

1994-07-01T23:59:59.000Z

373

Lighting Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Purple LED lamp Purple LED lamp Lighting Systems Lighting research is aimed at improving the energy efficiency of lighting systems in buildings and homes across the nation. The goal is to reduce lighting energy consumption by 50% over twenty years by improving the efficiency of light sources, and controlling and delivering illumination so that it is available, where and when needed, and at the required intensity. Research falls into four main areas: Sources and Ballasts, Light Distribution Systems, Controls and Communications, and Human Factors. Contacts Francis Rubinstein FMRubinstein@lbl.gov (510) 486-4096 Links Lighting Research Group Batteries and Fuel Cells Buildings Energy Efficiency Applications Commercial Buildings Cool Roofs and Heat Islands Demand Response Energy Efficiency Program and Market Trends

374

Nearby Outdoor Environmental Support of Older Adults' Yard Activities, Neighborhood Walking and Independent Living in the Community  

E-Print Network (OSTI)

to remain healthy and gives them the ability to access daily-life services, and thus extend their independent years at home. Nearby outdoor environments on residential sites and in the neighborhoods may influence older adults' independent living through...

Wang, Zhe

2011-02-22T23:59:59.000Z

375

Urban Energy Balance Obtained from the Comprehensive Outdoor Scale Model Experiment. Part I: Basic Features of the Surface Energy Balance  

Science Journals Connector (OSTI)

The objective of this study is to examine the basic features of the surface energy balance (SEB) using the data obtained from the Comprehensive Outdoor Scale Model (COSMO). COSMO is an idealized miniature city that has no vegetation, no human ...

Toru Kawai; Manabu Kanda

2010-07-01T23:59:59.000Z

376

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers Title Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers Publication Type Report LBNL Report Number LBNL-4951E Year of Publication 2011 Authors Coles, Henry C., Tae Won Han, Phillip N. Price, Ashok J. Gadgil, and William F. Tschudi Date Published 03/2011 Abstract There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: "closed" and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percentage of the recirculation air is "make-up" air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both "closed" and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups:

377

The energy saving potential of precooling incoming outdoor air by indirect evaporative cooling  

SciTech Connect

This paper investigates the energy saving potentials of using indirect evaporative coolers to precool incoming outdoor air as the first stage of a standard cooling system. For dry and moderately humid locations, either exhaust room air or outdoor air can be used as the secondary air to the indirect evaporative precooler with similar energy savings. Under these conditions, the use of outdoor air is recommended due to the simplicity in installing the duct system. For humid locations, the use of exhaust room air is recommended because the precooling capacity and energy savings will be greatly increased. For locations with short cooling seasons, the use of indirect evaporative coolers for precooling may not be worthwhile. The paper also gives some simplified indices for easily predicting the precooling capacity, energy savings and water consumption of an indirect evaporative precooler. These indices can be used for cooling systems with continuous operation, but further work is needed to determine whether the same indices are also suitable for cooling systems with intermittent operations.

Chen, P.; Qin, H.; Huang, Y.J.; Wu, H.; Blumstein, C.

1992-09-01T23:59:59.000Z

378

Estimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin  

Science Journals Connector (OSTI)

Abstract This work uses 194 outdoor particle size distributions (PSDs) from the literature to estimate single-pass heating, ventilating, and air-conditioning (HVAC) filter removal efficiencies for PM2.5 and ultrafine particles (UFPs: HVAC filters identified in the literature. Filters included those with a minimum efficiency reporting value (MERV) of 5, 6, 7, 8, 10, 12, 14, and 16, as well as HEPA filters. We demonstrate that although the MERV metric defined in ASHRAE Standard 52.2 does not explicitly account for UFP or PM2.5 removal efficiency, estimates of filtration efficiency for both size fractions increased with increasing MERV. Our results also indicate that outdoor PSD characteristics and assumptions for particle density and typical size-resolved infiltration factors (in the absence of HVAC filtration) do not drastically impact estimates of HVAC filter removal efficiencies for PM2.5. The impact of these factors is greater for UFPs; however, they are also somewhat predictable. Despite these findings, our results also suggest that MERV alone cannot always be used to predict UFP or PM2.5 removal efficiency given the various size-resolved removal efficiencies of different makes and models, particularly for MERV 7 and MERV 12 filters. This information improves knowledge of how the MERV designation relates to PM2.5 and UFP removal efficiency for indoor particles of outdoor origin. Results can be used to simplify indoor air quality modeling efforts and inform standards and guidelines.

Parham Azimi; Dan Zhao; Brent Stephens

2014-01-01T23:59:59.000Z

379

Worldwide outdoor round robin study of organic photovoltaic devices and modules  

Science Journals Connector (OSTI)

Abstract Accurate characterization and reporting of organic photovoltaic (OPV) device performance remains one of the important challenges in the field. The large spread among the efficiencies of devices with the same structure reported by different groups is significantly caused by different procedures and equipment used during testing. The presented article addresses this issue by offering a new method of device testing using “suitcase sample” approach combined with outdoor testing that limits the diversity of the equipment, and a strict measurement protocol. A round robin outdoor characterization of roll-to-roll coated OPV cells and modules conducted among 46 laboratories worldwide is presented, where the samples and the testing equipment were integrated in a compact suitcase that served both as a sample transportation tool and as a holder and test equipment during testing. In addition, an internet based coordination was used via plasticphotovoltaics.org that allowed fast and efficient communication among participants and provided a controlled reporting format for the results that eased the analysis of the data. The reported deviations among the laboratories were limited to 5% when compared to the Si reference device integrated in the suitcase and were up to 8% when calculated using the local irradiance data. Therefore, this method offers a fast, cheap and efficient tool for sample sharing and testing that allows conducting outdoor measurements of OPV devices in a reproducible manner.

Morten V. Madsen; Suren A. Gevorgyan; R. Pacios; J. Ajuria; I. Etxebarria; Jeff Kettle; Noel D. Bristow; Marios Neophytou; Stelios A. Choulis; Lucimara Stolz Roman; Teketel Yohannes; Andrea Cester; Pei Cheng; Xiaowei Zhan; Jiang Wu; Zhiyuan Xie; Wei-Chen Tu; Jr-Hau He; Christopher J Fell; Kenrick Anderson; Martin Hermenau; Davide Bartesaghi; L. Jan Anton Koster; Florian Machui; Irene González-Valls; Monica Lira-Cantu; Petr P. Khlyabich; Barry C. Thompson; Ritu Gupta; Kiruthika Shanmugam; Giridhar U. Kulkarni; Yulia Galagan; Antonio Urbina; Jose Abad; Roland Roesch; Harald Hoppe; P. Morvillo; E. Bobeico; Eugen Panaitescu; Latika Menon; Qun Luo; Zhenwu Wu; Changqi Ma; Artak Hambarian; Varuzhan Melikyan; M. Hambsch; Paul L. Burn; Paul Meredith; Thomas Rath; Sebastian Dunst; Gregor Trimmel; Giorgio Bardizza; Harald Müllejans; A.E. Goryachev; Ravi K. Misra; Eugene A. Katz; Katsuhiko Takagi; Shinichi Magaino; Hidenori Saito; Daisuke Aoki; Paul M. Sommeling; Jan M. Kroon; Tim Vangerven; Jean Manca; Jurgen Kesters; Wouter Maes; Olga D. Bobkova; Vasily A. Trukhanov; Dmitry Yu. Paraschuk; Fernando A. Castro; James Blakesley; Sachetan M Tuladhar; Jason Alexander Röhr; Jenny Nelson; Jiangbin Xia; Elif Alturk Parlak; Tülay Asl? Tumay; Hans-Joachim Egelhaaf; David M. Tanenbaum; Gretta Mae Ferguson; Robert Carpenter; Hongzheng Chen; Birger Zimmermann; Lionel Hirsch; Guillaume Wantz; Ziqi Sun; Pradeep Singh; Chaitnya Bapat; Ton Offermans; Frederik C. Krebs

2014-01-01T23:59:59.000Z

380

On approximate reasoning and minimal models for the development of robust outdoor vehicle navigation schemes  

SciTech Connect

Outdoor sensor-based operation of autonomous robots has revealed to be an extremely challenging problem, mainly because of the difficulties encountered when attempting to represent the many uncertainties which are always present in the real world. These uncertainties are primarily due to sensor imprecisions and unpredictability of the environment, i.e., lack of full knowledge of the environment characteristics and dynamics. Two basic principles, or philosophies, and their associated methodologies are proposed in an attempt to remedy some of these difficulties. The first principle is based on the concept of ``minimal model`` for accomplishing given tasks and proposes to utilize only the minimum level of information and precision necessary to accomplish elemental functions of complex tasks. This approach diverges completely from the direction taken by most artificial vision studies which conventionally call for crisp and detailed analysis of every available component in the perception data. The paper will first review the basic concepts of this approach and will discuss its pragmatic feasibility when embodied in a behaviorist framework. The second principle which is proposed deals with implicit representation of uncertainties using Fuzzy Set Theory-based approximations and approximate reasoning, rather than explicit (crisp) representation through calculation and conventional propagation techniques. A framework which merges these principles and approaches is presented, and its application to the problem of sensor-based outdoor navigation of a mobile robot is discussed. Results of navigation experiments with a real car in actual outdoor environments are also discussed to illustrate the feasibility of the overall concept.

Pin, F.G.

1993-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Variability of chlorination by-product occurrence in water of indoor and outdoor swimming pools  

Science Journals Connector (OSTI)

Swimming is one of the most popular aquatic activities. Just like natural water, public pool water may contain microbiological and chemical contaminants. The purpose of this study was to study the presence of chemical contaminants in swimming pools, in particular the presence of disinfection by-products (DBPs) such as trihalomethanes (THMs), haloacetic acids (HAAs) and inorganic chloramines (CAMi). Fifty-four outdoor and indoor swimming pools were investigated over a period of one year (monthly or bi-weekly sampling, according to the type of pool) for the occurrence of DBPs. The results showed that DBP levels in swimming pools were greater than DBP levels found in drinking water, especially for HAAs. Measured concentrations of \\{THMs\\} (97.9 vs 63.7 ?g/L in average) and \\{HAAs\\} (807.6 vs 412.9 ?g/L in average) were higher in outdoor pools, whereas measured concentrations of \\{CAMi\\} (0.1 vs 0.8 mg/L in average) were higher in indoor pools. Moreover, outdoor pools with heated water contained more \\{DBPs\\} than unheated pools. Finally, there was significant variability in tTHM, HAA9 and \\{CAMi\\} levels in pools supplied by the same municipal drinking water network, suggesting that individual pool characteristics (number of swimmers) and management strategies play a major role in DBP formation.

Sabrina Simard; Robert Tardif; Manuel J. Rodriguez

2013-01-01T23:59:59.000Z

382

The effects of outdoor heat exchanger hydrophobic treatment on the performance of an air source heat pump  

E-Print Network (OSTI)

THE EFFECTS OF OUTDOOR HEAT EXCHANGER HYDROPHOBIC TREATMENT ON THE PERFORMANCE OF AN AIR SOURCE HEAT PUMP A Thesis by BRANDON DEWAYNE PARKER Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment... of the requirements for the degree of MASTER OF SCIENCE May 1995 Major Subject: Mechanical Engineering THE EFFECTS OF OUTDOOR HEAT EXCHANGER HYDROPHOBIC TREATMENT ON THE PERFORMANCE OF AN AIR SOURCE HEAT PUMP A Thesis by BRANDON DEWAYNE PARKER Submitted...

Parker, Brandon DeWayne

2012-06-07T23:59:59.000Z

383

Texas A&M AgriLife Extension Service Procedures 24.01.01.X0.09 Outdoor Burning  

E-Print Network (OSTI)

during cold weather. 2.3 Domestic waste burning at a private residence when collection is not providedTexas A&M AgriLife Extension Service Procedures 24.01.01.X0.09 Outdoor Burning Approved: October 5 Review: August 27, 2014 Texas A&M AgriLife Extension Service Procedure 24.01.01.X0.09 Outdoor Burning

384

Texas A&M AgriLife Research Procedures 24.01.01.A0.09 Outdoor Burning  

E-Print Network (OSTI)

during cold weather. 2.3 Domestic waste burning at a private residence when collection is not providedTexas A&M AgriLife Research Procedures 24.01.01.A0.09 Outdoor Burning Approved: October 5, 2000: August 27, 2014 Texas A&M AgriLife Research Procedure 24.01.01.A0.09 Outdoor Burning Page 1 of 2

385

Revitalized Board Lays Out New Path amid EM's Recent Underground Tank  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Revitalized Board Lays Out New Path amid EM's Recent Underground Revitalized Board Lays Out New Path amid EM's Recent Underground Tank Waste Successes Revitalized Board Lays Out New Path amid EM's Recent Underground Tank Waste Successes August 20, 2012 - 12:00pm Addthis Cement trucks transport a specially formulated grout that is pumped into two underground waste tanks at the Savannah River Site as part of work to close the massive structures. Cement trucks transport a specially formulated grout that is pumped into two underground waste tanks at the Savannah River Site as part of work to close the massive structures. A view of the interior of the Integrated Waste Treatment Unit at the Idaho site. A view of the interior of the Integrated Waste Treatment Unit at the Idaho site. Cement trucks transport a specially formulated grout that is pumped into two underground waste tanks at the Savannah River Site as part of work to close the massive structures.

386

GRR/Elements/14-CA-c.12 - Does the DOGGR Approve the Underground Injection  

Open Energy Info (EERE)

- Does the DOGGR Approve the Underground Injection - Does the DOGGR Approve the Underground Injection Project < GRR‎ | Elements Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections 14-CA-c.12 - Does the DOGGR Approve the Underground Injection Project After the end of the comment period and after reviewing any proposed revisions furnished by the Regional Board, the State Board decides whether to approve the Underground Injection Project. Logic Chain No Parents \V/ GRR/Elements/14-CA-c.12 - Does the DOGGR Approve the Underground Injection Project (this page) \V/ No Dependents Under Development Add.png Add an Element Retrieved from "http://en.openei.org/w/index.php?title=GRR/Elements/14-CA-c.12_-_Does_the_DOGGR_Approve_the_Underground_Injection_Project&oldid=539630

387

GRR/Section 14-WA-c - Underground Injection Control Permit | Open Energy  

Open Energy Info (EERE)

GRR/Section 14-WA-c - Underground Injection Control Permit GRR/Section 14-WA-c - Underground Injection Control Permit < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 14-WA-c - Underground Injection Control Permit 14-WA-c - Underground Injection Control Permit.pdf Click to View Fullscreen Contact Agencies Washington State Department of Ecology Regulations & Policies Chapter 173-218 WAC Non-endangerment Standard Triggers None specified The Safe Drinking Water Act requires Washington to implement technical criteria and standards to protect underground sources of drinking water from contamination. Under Chapter 173-218 WAC, the Washington State Department of Ecology (WSDE) regulates and permits underground injection control (UIC) wells in Washington. The Environmental Protection Agency

388

GRR/Section 18-WA-a - Underground Storage Tank Process | Open Energy  

Open Energy Info (EERE)

GRR/Section 18-WA-a - Underground Storage Tank Process GRR/Section 18-WA-a - Underground Storage Tank Process < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 18-WA-a - Underground Storage Tank Process 18-WA-a - Underground Storage Tank Process.pdf Click to View Fullscreen Contact Agencies Washington State Department of Ecology Regulations & Policies Revised Code of Washington Chapter 90.76 Washington Administrative Code Chapter 173-360 Triggers None specified Washington has a federally-approved state Underground Storage Tank (UST) program regulated by the Washington State Department of Ecology (WSDE) under Revised Code of Washington Chapter 90.76 and Washington Administrative Code Chapter 173-360. Washington defines an "Underground

389

GRR/Section 18-OR-a - State Underground Storage Tank | Open Energy  

Open Energy Info (EERE)

GRR/Section 18-OR-a - State Underground Storage Tank GRR/Section 18-OR-a - State Underground Storage Tank < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 18-OR-a - State Underground Storage Tank 18ORAStateUndergroundStorageTank (1).pdf Click to View Fullscreen Contact Agencies Oregon Department of Environmental Quality Regulations & Policies OAR 340-150: Underground Storage Tank Rules Triggers None specified Click "Edit With Form" above to add content 18ORAStateUndergroundStorageTank (1).pdf Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Flowchart Narrative _ 18-OR-a.1 - Application for General Permit Registration Certificate, EPA

390

Like City Lights, Receding: ANSi Artwork and the Digital Underground, 1985-2000.  

E-Print Network (OSTI)

??The rise of the Internet has obscured knowledge of the modes of mass online interaction that preceded it. Foremost amongst these was the Bulletin Board… (more)

Hargadon, Michael A

2011-01-01T23:59:59.000Z

391

Understanding motivations of potential partners to develop a public outdoor recreation center in an urban area  

Science Journals Connector (OSTI)

Abstract Participation in traditional outdoor activities has declined in recent decades, causing concern for agencies involved in managing areas where citizens can pursue these activities. With limited resources to address this complex challenge, collaboration among several stakeholders seems to provide a win–win solution. An outdoor center that offers activities such as fishing, hunting, trapping and canoeing is one collaborative option. The purpose of this study is to better understand the motivations of organizations to collaborate in the development and operation of an outdoor center in the U.S. state of Michigan. Expectancy theory and social exchange theory provided a unique approach to understanding potential partners? expectations regarding positive outcomes and costs of collaboration. Through semi-structured interviews with potential partners, researchers found that a prevalent expected benefit of collaboration is the presence of a venue near diverse, urban populations at which to conduct outdoor programming. In addition, patterns emerged in the anticipated benefits from (and contributions to) the partnership based on the types of organizations interviewed. Insights into organizations? motivations to collaborate, based on these two theoretical frameworks, will aid recreation providers in creating appropriate selection criteria for partners and strategies for engaging them in collaborative projects to enhance outdoor recreation participation. Management implications When planning a new recreation center, it is important to identify potential collaborating organizations, and to integrate and coordinate the expectations of those organizations as early as possible. In order to balance the varying interests, it is helpful for managers: • To categorize potential collaborators based on the nature of their relationship with the initiating organization (e.g., participant-focused, activity-focused, education-focused, manufacturers/retailers), as these classifications are typically characterized by different motivations and expectations; • To understand individual preferences and agendas of each of the respective future partners; • To emphasize the increasing efficiencies associated with cooperation; • To increase their awareness of both benefits and costs anticipated by the potential partners; and • To consider the various types of potential contributions, beyond financial support, that partners can provide. These may include: equipment, experts, participants and volunteers.

Christine Carmichael; Dan McCole

2014-01-01T23:59:59.000Z

392

E-Print Network 3.0 - aging underground reinforced Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

University Summary: -Infrastructure Developments in Southeast Asia: Case Study of Thailand Underground Suchatvee Suwansawat Dean of Engineering... is the second phase...

393

Site Characterization, Sustainability Evaluation and Life Cycle Emissions Assessment of Underground Coal Gasification.  

E-Print Network (OSTI)

??Underground Coal Gasification (UCG), although not a new concept, is now attracting considerable global attention as a viable process to provide a âcleanâ and economic… (more)

Hyder, Zeshan

2012-01-01T23:59:59.000Z

394

You've got that Sinking Feeling: Measuring Subsidence above Abandoned Underground Mines in Ohio, USA.  

E-Print Network (OSTI)

??As a result of more than 200 years of underground coal mining, many urbanized areas throughout Ohio, USA, are susceptible to land subsidence. Approximately 6,000… (more)

Siemer, Kyle W

2013-01-01T23:59:59.000Z

395

Electromagnetic full wave modal analysis of frequency-dependent underground cables.  

E-Print Network (OSTI)

??In this thesis, a new method has been proposed for calculating the frequencydependent parameters of underground cables. The method uses full wave formulation for calculating… (more)

Habib, Md. Shahnoor

2011-01-01T23:59:59.000Z

396

Alabama Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Alabama Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1995 1,379 1,377 1,113 1,113 1,140 1,182 1,218 1,436 2,028 1,955 1,766 1,365 1996 1,311 1,014 852 1,006 1,373 2,042 2,247 2,641 3,081 3,198 3,069 2,309 1997 1,778 1,594 1,619 1,749 2,020 2,113 2,156 2,443 2,705 2,956 2,713 2,713 1998 1,963 1,775 1,527 1,772 1,917 2,540 2,531 2,730 2,329 2,942 2,943 2,805 1999 1,992 1,878 1,566 1,703 2,173 2,383 2,618 2,699 3,101 3,024 3,158 2,969 2000 2,055 2,053 2,368 2,302 2,392 2,999 3,080 3,080 2,970 2,828 2,624 2,539 2001 2,210 2,451 1,847 2,041 1,997 2,574 2,728 2,841 2,859 2,739 5,527 5,538

397

Michigan Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Michigan Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 706,889 648,325 624,515 616,656 665,124 729,161 807,726 878,119 930,596 949,922 938,864 867,940 1991 743,402 679,102 654,930 682,092 729,387 786,753 845,224 891,823 911,554 952,843 894,499 818,602 1992 733,877 658,347 592,859 592,608 637,515 705,740 780,590 849,043 917,537 946,090 899,631 810,348 1993 710,139 607,908 543,589 559,454 637,732 723,706 807,040 889,450 955,444 989,143 937,100 847,136 1994 702,694 613,074 582,416 623,584 696,448 770,914 845,328 922,211 987,829 1,019,096 999,421 936,290 1995 830,235 717,515 666,164 665,004 718,094 783,569 857,995 914,295 966,578 998,665 931,432 813,622

398

West Virginia Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) West Virginia Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 406,358 395,084 390,792 397,000 415,841 433,111 451,251 467,272 480,567 484,278 484,868 464,807 1991 434,160 413,996 410,940 418,771 433,924 450,027 464,274 474,984 483,421 487,004 475,927 453,446 1992 423,942 396,889 367,681 369,328 393,606 411,353 433,399 452,065 465,496 478,316 472,378 449,402 1993 417,527 374,171 344,142 349,414 388,771 415,925 435,814 454,993 475,298 482,458 468,770 435,687 1994 379,825 347,246 330,957 352,059 377,614 406,195 433,763 456,009 476,854 482,830 475,145 450,055 1995 406,251 364,959 352,876 358,628 383,018 407,328 422,458 431,357 449,075 463,546 440,460 401,144

399

AGA Western Consuming Region Natural Gas Underground Storage Withdrawals  

Gasoline and Diesel Fuel Update (EIA)

Gas Underground Storage Withdrawals (Million Cubic Feet) Gas Underground Storage Withdrawals (Million Cubic Feet) AGA Western Consuming Region Natural Gas Underground Storage Withdrawals (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1994 58,880 70,469 16,774 11,878 2,078 1,522 2,158 2,524 1,024 3,314 29,483 47,719 1995 56,732 27,801 27,857 15,789 4,280 2,252 3,265 11,858 5,401 6,025 14,354 53,469 1996 89,320 52,624 24,847 9,346 4,785 4,298 12,886 21,661 6,866 14,578 24,096 48,438 1997 73,240 41,906 22,756 15,182 4,297 3,613 5,381 8,030 7,770 12,343 22,625 88,975 1998 54,800 50,704 27,864 16,746 3,265 2,619 6,278 6,049 5,822 4,599 14,013 62,377 1999 54,762 45,467 35,081 31,196 7,773 3,792 4,982 14,342 6,642 10,488 15,128 54,531

400

AGA Western Consuming Region Natural Gas Injections into Underground  

Gasoline and Diesel Fuel Update (EIA)

Gas Injections into Underground Storage (Million Cubic Feet) Gas Injections into Underground Storage (Million Cubic Feet) AGA Western Consuming Region Natural Gas Injections into Underground Storage (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1994 2,449 542 13,722 29,089 48,055 33,801 35,146 27,858 45,903 22,113 5,766 6,401 1995 2,960 9,426 8,840 10,680 42,987 47,386 37,349 22,868 31,053 25,873 15,711 3,003 1996 2,819 8,696 9,595 20,495 41,216 36,086 25,987 20,787 24,773 17,795 13,530 9,122 1997 6,982 4,857 15,669 28,479 47,040 49,438 38,542 31,080 29,596 23,973 10,066 1,975 1998 5,540 1,847 14,429 21,380 49,816 48,423 30,073 34,243 31,710 34,744 26,456 6,404 1999 4,224 3,523 10,670 17,950 41,790 42,989 40,381 26,942 30,741 20,876 18,806 4,642

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Virginia Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Virginia Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1997 0 0 0 0 0 0 0 0 0 0 0 0 1998 3,654 3,215 2,903 3,108 3,416 3,720 3,906 4,241 4,507 4,731 4,691 4,330 1999 4,004 3,548 3,215 3,397 3,666 3,872 4,078 4,280 4,691 4,792 4,599 4,118 2000 3,398 3,283 3,289 3,456 3,735 3,941 4,160 4,366 4,357 4,785 4,434 3,720 2001 3,183 3,135 2,844 3,275 3,788 4,180 4,424 4,728 4,988 5,013 5,073 4,875 2002 4,401 3,728 3,339 3,462 4,014 4,285 4,568 4,709 5,017 5,225 4,945 4,451 2003 3,429 2,933 2,754 3,047 3,494 3,969 4,381 5,469 6,083 6,035 6,003 5,458 2004 4,324 3,958 3,647 3,806 4,539 4,866 5,121 5,915 6,379 7,223 7,191 6,185

402

Oregon Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Oregon Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 6,996 5,657 4,959 6,140 7,648 8,892 9,656 10,292 10,664 10,853 10,808 10,057 1991 8,982 8,017 6,250 5,271 5,985 7,539 8,997 10,089 10,763 11,102 11,125 10,638 1992 9,070 7,530 5,944 5,502 7,074 8,614 9,809 10,819 11,272 11,445 10,346 9,766 1993 7,848 6,452 5,724 5,298 6,942 8,240 9,421 10,463 11,041 11,531 10,800 9,697 1994 8,436 7,309 6,364 5,544 6,754 8,253 9,449 10,524 11,208 11,462 11,025 10,388 1995 8,710 8,325 7,885 8,752 9,932 10,965 11,661 11,661 12,147 12,147 12,090 11,268 1996 10,016 9,076 8,424 8,293 9,015 10,188 11,321 11,758 11,862 11,655 11,103 9,863

403

AGA Producing Region Natural Gas Underground Storage Withdrawals (Million  

Gasoline and Diesel Fuel Update (EIA)

Gas Underground Storage Withdrawals (Million Cubic Feet) Gas Underground Storage Withdrawals (Million Cubic Feet) AGA Producing Region Natural Gas Underground Storage Withdrawals (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1994 201,567 147,250 61,339 23,149 9,789 29,178 13,371 19,352 10,151 24,102 52,809 137,962 1995 166,242 120,089 100,955 31,916 17,279 19,712 35,082 62,364 16,966 33,762 102,735 181,097 1996 223,932 157,642 141,292 36,788 27,665 26,393 32,861 27,599 20,226 34,000 116,431 142,519 1997 204,601 103,715 43,894 54,285 24,898 34,122 65,631 42,757 30,579 32,257 113,422 180,582 1998 143,042 69,667 97,322 25,555 30,394 38,537 33,314 37,034 51,903 17,812 60,078 168,445 1999 189,816 77,848 104,690 44,930 22,829 26,085 58,109 60,549 25,888 43,790 66,980 165,046

404

AGA Eastern Consuming Region Natural Gas Underground Storage Withdrawals  

Gasoline and Diesel Fuel Update (EIA)

Gas Underground Storage Withdrawals (Million Cubic Feet) Gas Underground Storage Withdrawals (Million Cubic Feet) AGA Eastern Consuming Region Natural Gas Underground Storage Withdrawals (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1994 530,741 349,007 159,102 30,353 9,093 4,218 8,493 5,462 6,537 22,750 119,120 256,340 1995 419,951 414,116 196,271 76,470 8,845 14,449 13,084 9,496 3,715 25,875 247,765 398,851 1996 435,980 333,314 236,872 66,149 12,958 4,261 2,804 5,141 5,152 24,515 213,277 269,811 1997 474,777 267,717 218,640 76,956 11,974 4,401 7,277 5,503 5,269 39,662 165,807 309,399 1998 339,858 244,813 256,560 37,278 8,764 11,317 14,830 15,207 16,026 23,854 94,110 287,801 1999 437,182 261,305 244,041 43,642 13,904 11,738 17,499 14,984 9,984 37,822 122,731 385,958

405

AGA Producing Region Natural Gas Injections into Underground Storage  

Gasoline and Diesel Fuel Update (EIA)

Gas Injections into Underground Storage (Million Cubic Feet) Gas Injections into Underground Storage (Million Cubic Feet) AGA Producing Region Natural Gas Injections into Underground Storage (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1994 20,366 29,330 55,297 93,538 129,284 83,943 104,001 98,054 88,961 65,486 49,635 27,285 1995 24,645 25,960 57,833 78,043 101,019 100,926 77,411 54,611 94,759 84,671 40,182 33,836 1996 34,389 48,922 38,040 76,100 98,243 88,202 88,653 109,284 125,616 91,618 37,375 48,353 1997 45,327 35,394 89,625 83,137 107,821 99,742 71,360 95,278 116,634 117,497 49,750 33,170 1998 41,880 59,324 73,582 119,021 128,323 96,261 107,136 94,705 87,920 129,117 58,026 47,924 1999 35,830 50,772 49,673 80,879 110,064 100,132 72,348 67,286 103,587 79,714 66,465 32,984

406

New Mexico Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) New Mexico Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 32,289 31,416 31,096 32,921 25,403 33,699 37,281 40,474 42,033 45,200 46,210 43,675 1991 40,230 38,226 36,059 39,127 42,052 45,061 46,102 44,144 46,786 46,696 46,457 47,414 1992 45,395 44,683 43,948 42,349 42,253 42,795 40,695 42,640 43,838 46,401 45,364 45,776 1993 43,130 38,966 38,843 35,916 38,621 39,842 40,111 37,793 38,782 40,310 37,597 37,680 1994 34,718 33,061 33,341 31,698 33,727 34,304 34,155 34,287 38,474 40,591 40,040 39,500 1995 37,356 37,353 37,790 38,013 39,236 40,341 40,358 39,269 39,788 39,823 38,746 37,256

407

AGA Eastern Consuming Region Natural Gas Underground Storage Volume  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) AGA Eastern Consuming Region Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1994 3,605,263 3,281,694 3,164,033 3,297,696 3,531,074 3,786,195 4,043,225 4,279,875 4,477,279 4,588,167 4,522,088 4,292,649 1995 3,905,789 3,514,201 3,360,765 3,369,823 3,576,559 3,812,014 3,968,751 4,159,006 4,362,855 4,483,271 4,279,539 3,905,710 1996 3,483,209 3,190,123 2,987,233 3,052,606 3,272,105 3,557,334 3,859,973 4,122,060 4,364,848 4,508,821 4,334,814 4,094,033 1997 3,630,708 3,381,047 3,190,271 3,205,661 3,398,322 3,660,850 3,905,985 4,151,456 4,379,374 4,493,802 4,383,068 4,084,339 1998 3,774,740 3,544,699 3,335,505 3,436,983 3,680,419 3,909,517 4,166,130 4,309,452 4,461,762 4,580,963 4,542,742 4,295,021

408

Minnesota Natural Gas Underground Storage Volume (Million Cubic Feet)  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) Minnesota Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 6,363 5,796 5,866 6,343 6,672 6,784 6,916 6,964 7,025 7,052 7,050 6,662 1991 6,206 5,968 5,862 6,017 6,274 6,586 6,878 6,869 6,962 6,928 6,846 6,789 1992 6,341 6,211 5,883 5,675 6,064 6,371 6,668 6,848 6,974 6,970 6,962 6,759 1993 6,363 5,945 5,527 5,479 5,796 6,140 6,549 6,678 6,916 6,999 6,923 6,612 1994 6,085 5,890 5,700 5,543 5,892 6,265 6,634 6,836 6,985 6,983 6,979 6,907 1995 6,394 5,917 5,660 5,613 5,944 6,207 6,513 6,744 6,985 6,991 6,988 6,733 1996 5,952 5,692 5,470 5,558 5,924 6,219 6,506 6,716 6,918 6,951 6,920 6,693

409

AGA Producing Region Natural Gas Underground Storage Volume (Million Cubic  

U.S. Energy Information Administration (EIA) Indexed Site

Underground Storage Volume (Million Cubic Feet) Underground Storage Volume (Million Cubic Feet) AGA Producing Region Natural Gas Underground Storage Volume (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1994 1,433,462 1,329,400 1,322,914 1,388,877 1,498,496 1,553,493 1,643,445 1,714,361 1,785,350 1,819,344 1,810,791 1,716,773 1995 1,601,428 1,510,175 1,467,414 1,509,666 1,586,445 1,662,195 1,696,619 1,688,515 1,768,189 1,818,098 1,757,160 1,613,046 1996 1,436,765 1,325,994 1,223,139 1,264,513 1,334,894 1,395,779 1,443,970 1,525,797 1,631,006 1,686,652 1,614,154 1,519,539 1997 1,379,108 1,303,888 1,356,678 1,385,616 1,461,221 1,536,339 1,542,480 1,596,011 1,683,987 1,770,002 1,707,810 1,559,636 1998 1,456,136 1,442,993 1,420,644 1,515,050 1,610,474 1,666,304 1,739,745 1,803,097 1,840,984 1,950,772 1,945,897 1,807,163

410

Lighting Renovations  

Energy.gov (U.S. Department of Energy (DOE))

When undertaking a lighting renovation in a Federal building, daylighting is the primary renewable energy opportunity. Photovoltaics (PV) also present an excellent opportunity. While this guide...

411

Cerenkov Light  

ScienceCinema (OSTI)

The bright blue glow from nuclear reactors is Cerenkov light. Karl Slifer describes how nuclear physicists can use this phenomenon to study the nucleus of the atom.

Slifer, Karl

2014-05-22T23:59:59.000Z

412

Time correlations of high energy muons in an underground detector  

E-Print Network (OSTI)

We present the result of a search for correlations in the arrival times of high energy muons collected from 1995 till 2000 with the streamer tube system of the complete MACRO detector at the underground Gran Sasso Lab. Large samples of single muons (8.6 million), double muons (0.46 million) and multiple muons with multiplicities from 3 to 6 (0.08 million) were selected. These samples were used to search for time correlations of cosmic ray particles coming from the whole upper hemisphere or from selected space cones. The results of our analyses confirm with high statistics a random arrival time distribution of high energy cosmic rays.

Y. Becherini; S. Cecchini; T. Chiarusi; M. Cozzi; H. Dekhissi; J. Derkaoui; L. S. Esposito; G. Giacomelli; M. Giorgini; N. Giglietto; F. Maaroufi; G. Mandrioli; A. Margiotta; S. Manzoor; A. Moussa; L. Patrizii; V. Popa; M. Sioli; G. Sirri; M. Spurio; V. Togo

2005-02-12T23:59:59.000Z

413

Cosmic Ray Sun Shadow in Soudan 2 Underground Muon Flux  

E-Print Network (OSTI)

The absorption of cosmic rays by the sun produces a shadow at the earth. The angular offset and broadening of the shadow are determined by the magnitude and structure of the interplanetary magnetic field (IPMF) in the inner solar system. We report the first measurement of the solar cosmic ray shadow by detection of deep underground muon flux in observations made during the entire ten-year interval 1989 to 1998. The sun shadow varies significantly during this time, with a $3.3\\sigma$ shadow observed during the years 1995 to 1998.

Soudan 2 Collaboration

1999-05-24T23:59:59.000Z

414

SUNLAB - The Project of a Polish Underground Laboratory  

SciTech Connect

The project of the first Polish underground laboratory SUNLAB, in the Polkowice-Sieroszowice copper mine, belonging to the KGHM Polska Miedz S.A. holding, is presented. Two stages of the project are foreseen: SUNLAB1 (a small laboratory in the salt layer exhibiting extremely low level of natural radioactivity) and SUNLAB2 (a big laboratory in the anhydrite layer, able to host the next generation liquid argon detector - GLACIER, which is considered within the LAGUNA FP7 project). The results of the natural radioactivity background measurements performed in the Polkowice-Sieroszowice salt cavern are also briefly summarized.

Kisiel, J.; Dorda, J.; Konefall, A.; Mania, S.; Szeglowski, T. [Institute of Physics, University of Silesia, Universytecka 4, 40-007 Katowice (Poland); Budzanowski, M.; Haranczyk, M.; Kozak, K.; Mazur, J.; Mietelski, J. W.; Puchalska, M.; Szarska, M.; Tomankiewicz, E.; Zalewska, A. [Institute of Nuclear Physics PAN, Radzikowskiego 152, Krakow (Poland); Chorowski, M.; Polinski, J. [Wroclaw University of Technology, Wroclaw (Poland); Cygan, S.; Hanzel, S.; Markiewicz, A.; Mertuszka, P. [KGHM CUPRUM CBR, Wroclaw (Poland)

2010-11-24T23:59:59.000Z

415

Method for maximizing shale oil recovery from an underground formation  

DOE Patents (OSTI)

A method for maximizing shale oil recovery from an underground oil shale formation which has previously been processed by in situ retorting such that there is provided in the formation a column of substantially intact oil shale intervening between adjacent spent retorts, which method includes the steps of back filling the spent retorts with an aqueous slurry of spent shale. The slurry is permitted to harden into a cement-like substance which stabilizes the spent retorts. Shale oil is then recovered from the intervening column of intact oil shale by retorting the column in situ, the stabilized spent retorts providing support for the newly developed retorts.

Sisemore, Clyde J. (Livermore, CA)

1980-01-01T23:59:59.000Z

416

Superconducting gravity gradiometers for underground target recognition. Final report  

SciTech Connect

One of the most formidable intelligence challenges existing in the non-proliferation community is the detection of buried targets. The physical parameter that all buried targets share, whether the target is buried armaments, a tunnel or a bunker, is mass. In the case of buried armaments, there is an excess mass (higher density) compared to the surrounding area; for a tunnel or bunker, the mass is missing. In either case, this difference in mass generates a distinct gravitational signature. The Superconducting Gravity Gradiometer project at Sandia worked toward developing an airborne device for the detection of these underground structures.

Adriaans, M.J.

1998-01-01T23:59:59.000Z

417

Coalbed methane production enhancement by underground coal gasification  

SciTech Connect

The sub-surface of the Netherlands is generally underlain by coal-bearing Carboniferous strata at greater depths (at many places over 1,500 m). These coal seams are generally thinner than 3 meter, occur in groups (5--15) within several hundred meters and are often fairly continuous over many square kilometers. In many cases they have endured complex burial history, influencing their methane saturation. In certain particular geological settings, a high, maximum coalbed methane saturation, may be expected. Carboniferous/Permian coals in the Tianjin-region (China) show many similarities concerning geological settings, rank and composition. Economical coalbed methane production at greater depths is often obstructed by the (very) low permeabilities of the coal seams as with increasing depth the deformation of the coal reduces both its macro-porosity (the cleat system) and microporosity. Experiments in abandoned underground mines, as well as after underground coal gasification tests indicate ways to improve the prospects for coalbed methane production in originally tight coal reservoirs. High permeability areas can be created by the application of underground coal gasification of one of the coal seams of a multi-seam cycle with some 200 meter of coal bearing strata. The gasification of one of the coal seams transforms that seam over a certain area into a highly permeable bed, consisting of coal residues, ash and (thermally altered) roof rubble. Additionally, roof collapse and subsidence will destabilize the overburden. In conjunction this will permit a better coalbed methane production from the remaining surrounding parts of the coal seams. Moreover, the effects of subsidence will influence the stress patterns around the gasified seam and this improves the permeability over certain distances in the coal seams above and below. In this paper the effects of the combined underground coal gasification and coalbed methane production technique are regarded for a single injection well. Known geotechnical aspects are combined with results from laboratory experiments on compaction of thermally treated rubble. An axi-symmetric numerical model is used to determine the effects induced by the gasified coal seam. The calculation includes the rubble formation, rubble compaction and induced stress effects in the overlying strata. Subsequently the stress effects are related to changes in coal permeability, based on experimental results of McKee et al.

Hettema, M.H.H.; Wolf, K.H.A.A.; Neumann, B.V.

1997-12-31T23:59:59.000Z

418

Northern Lights  

NLE Websites -- All DOE Office Websites (Extended Search)

Northern Lights Northern Lights Nature Bulletin No. 178-A February 6, 1965 Forest Preserve District of Cook County Seymour Simon, President Roland F. Eisenbeis, Supt. of Conservation NORTHERN LIGHTS To a person seeing the Aurora Borealis or "northern lights" for the first time, it is an uncanny awe-inspiring spectacle. Sometimes it begins as a glow of red on the northern horizon, ominously suggesting a great fire, gradually changing to a curtain of violet-white, or greenish-yellow light extending from east to west. Some times this may be transformed to appear as fold upon fold of luminous draperies that march majestically across the sky; sometimes as a vast multitude of gigantic flaming swords furiously slashing at the heavens; sometimes as a flowing crown with long undulating colored streamers fanning downward and outward.

419

Evaluation of energy system analysis techniques for identifying underground facilities  

SciTech Connect

This report describes the results of a study to determine the feasibility and potential usefulness of applying energy system analysis techniques to help detect and characterize underground facilities that could be used for clandestine activities. Four off-the-shelf energy system modeling tools were considered: (1) ENPEP (Energy and Power Evaluation Program) - a total energy system supply/demand model, (2) ICARUS (Investigation of Costs and Reliability in Utility Systems) - an electric utility system dispatching (or production cost and reliability) model, (3) SMN (Spot Market Network) - an aggregate electric power transmission network model, and (4) PECO/LF (Philadelphia Electric Company/Load Flow) - a detailed electricity load flow model. For the purposes of most of this work, underground facilities were assumed to consume about 500 kW to 3 MW of electricity. For some of the work, facilities as large as 10-20 MW were considered. The analysis of each model was conducted in three stages: data evaluation, base-case analysis, and comparative case analysis. For ENPEP and ICARUS, open source data from Pakistan were used for the evaluations. For SMN and PECO/LF, the country data were not readily available, so data for the state of Arizona were used to test the general concept.

VanKuiken, J.C.; Kavicky, J.A.; Portante, E.C. [and others

1996-03-01T23:59:59.000Z

420

Active control of underground stresses through rock pressurization  

SciTech Connect

To significantly increase the stability of underground excavations while exploiting the full advantages of confined rock strength, methods must be developed to actively control the distribution of stresses near the excavation. This US Bureau of Mines study examines theoretical and practical aspects of rock pressurization, an active stress control concept that induces compressive stress in the wall rock through repeated hydraulic fracturing with a settable fluid. Numerical analyses performed by incorporating the rock pressurization concept into a variety of boundary-element models indicate that rock pressurization has the potential to improve underground excavation stability in three ways: (1) by relocating stress concentrations away from the weak opening surface to stronger, confined wall rock; (2) by inducing additional stresses in a biaxial stress field to reduce the difference between the principal stress components near the surface of the opening, and (3) by counteracting the tensile stresses induced in the rock around internally loaded openings. Practical aspects of the rock pressurization concept were investigated through a series of hydraulic fracturing experiments. The use of sulfur as a settable fluid for hydraulic fracturing was demonstrated, although problems related to sulfur viscosity suggest that other molten materials, such as wax, may be better suited to practical field application of the rock pressurization concept.

Vandergrift, T.L.

1995-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Underground engineering at the Basalt Waste Isolation Project  

SciTech Connect

A special task group was organized by the US National Committee for Rock Mechanics and the Board on Radioactive Waste Management of the National Research Council to address issues relating to the geotechnical site characterization program for an underground facility to house high-level radioactive waste of the Basalt Waste Isolation Project (BWIP). Intended to provide an overview of the geotechnical program, the study was carried out by a task group consisting of ten members with expertise in the many disciplines required to successfully complete such a project. The task group recognized from the outset that the short time frame of this study would limit its ability to address all geotechnical issues in detail. Geotechnical issues were considered to range from specific technical aspects such as in-situ testing for rock mass permeability; rock hardness testing in the laboratory; or geologic characterizations and quantification of joints, to broader aspects of design philosophy, data collection, and treatment of uncertainty. The task group chose to focus on the broader aspects of underground design and construction, recognizing that the BWIP program utilizes a peer review group on a regular basis which reviews the specific technical questions related to geotechnical engineering. In this way, it was hoped that the review provided by the task group would complement those prepared by the BWIP peer review group.

Not Available

1987-01-01T23:59:59.000Z

422

RCRA closure plan for underground storage tank 105-C  

SciTech Connect

A Reactor Department program for repairing heat exchangers created a low level radioactive waste, which was held in underground storage tank (UST) 105-C, hereafter referred to as the tank. According to Procedures used at the facility, the waste`s pH was adjusted to the 8.0--12.0 range before shipping it to the SRS Waste Management Department. For this reason, area personnel did not anticipate that the waste which is currently contained in the tank would have corrosive hazardous characteristic. However, recent analysis indicates that waste contained in the tank has a pH of greater than 12.5, thereby constituting a hazardous waste. Because the Department of Energy-Savannah River Office (DOE-SR) could not prove that the hazardous waste had been stored in the tank for less than 90 days, the State of South Carolina Department of Health and Environmental Control (SCDHEC) alleged that DOE-SR was in violation of the 1976 Code of Laws of South Carolina. As agreed in Settlement Agreement 90-74-SW between the DOE and SCDHEC, this is the required closure plan for Tank 105-C. The purpose of this document is to present SCDHEC with an official plan for closing the underground storage tank. Upon approval by SCDHEC, the schedule for closure will be an enforceable portion of this agreement.

Miles, W.C. Jr.

1990-10-01T23:59:59.000Z

423

Using Daylight to Light the Access Zone of Road Tunnels  

NLE Websites -- All DOE Office Websites (Extended Search)

Using Daylight to Light the Access Zone of Road Tunnels Using Daylight to Light the Access Zone of Road Tunnels Speaker(s): Eliyahu Ne'eman Date: March 4, 2003 - 12:00pm Location: Bldg. 90 Lighting guides for roadway tunnels specify relatively high luminances for the "access zone" into the tunnel. They are needed to allow the eyes of the driver sufficient time to adapt during the short period of the transition from the outdoor natural daylight levels to the fairly low luminances along the main length of the tunnel. Usually, the necessary high luminances are provided by rows of costly luminaries which consume a lot of electricity during peak use periods and need a good deal of maintenance. To save some electric power, controls are used to dim the lighting on cloudy hours. Daylight has been used for the access zone in several tunnels around the

424

Chemical and physical controls on waters discharged from abandoned underground coal mines  

Science Journals Connector (OSTI)

...abandoned underground coal mines D. L. Lopez M...mines in high-sulphur coal are a major source of acid mine drainage in Appalachia. Studies of mines in...abandoned underground coal mines, tailing deposits...1995, with records of mining dating to as early as...

D. L. López; M. W. Stoertz

425

AHIGHLY INSTRUMENTED UNDERGROUND RESEARCH GALLERY AS A MONITORING CONCEPT FOR RADIOACTIVE WASTE CELLS -DATA  

E-Print Network (OSTI)

AHIGHLY INSTRUMENTED UNDERGROUND RESEARCH GALLERY AS A MONITORING CONCEPT FOR RADIOACTIVE WASTE monitoring system of underground disposal for the French long-lived, intermediate and high level radioactive is a concrete liner in a tunnel aiming at support the mechanical pressure of the host rock. A 3.6 meter long

Boyer, Edmond

426

Permanent Closure of MFC Biodiesel Underground Storage Tank 99ANL00013  

SciTech Connect

This closure package documents the site assessment and permanent closure of the Materials and Fuels Complex biodiesel underground storage tank 99ANL00013 in accordance with the regulatory requirements established in 40 CFR 280.71, “Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.”

Kerry L. Nisson

2012-10-01T23:59:59.000Z

427

Hydrologic resources management program and underground test area operable unit fy 1997  

SciTech Connect

This report present the results of FY 1997 technical studies conducted by the Lawrence Livermore National Laboratory (LLNL) as part of the Hydrology and Radionuclide Migration Program (HRMP) and Underground Test Area Operable Unit (UGTA). The HRMP is sponsored by the US Department of Energy to assess the environmental (radiochemical and hydrologic) consequences of underground nuclear weapons testing at the Nevada Test Site.

Smith, D. F., LLNL

1998-05-01T23:59:59.000Z

428

Supersonic Air Jets Preserve Tree Roots in Underground Pipeline Installation1  

E-Print Network (OSTI)

Supersonic Air Jets Preserve Tree Roots in Underground Pipeline Installation1 Rob Gross 2 trenching operations for pipeline installation. Although mechanical soil excavation using heavy equipment are routinely installed, repaired, and replaced underground. During soil excavation, tree and other plant roots

Standiford, Richard B.

429

State of the art analysis of online fault location on AC cables in underground transmission systems  

E-Print Network (OSTI)

, such as 400 kV transmission lines, will also be undergrounded gradually as more experience is gath- ered of underground cables for the transmission level. In Denmark, as a leading country, the entire 150 kV and 132 kV on transmission level fault location methods have been focused on overhead lines. Because of the very different

Bak, Claus Leth

430

Simultaneous Sampling of Indoor and Outdoor Airborne Radioactivity after the Fukushima Daiichi Nuclear Power Plant Accident  

Science Journals Connector (OSTI)

Simultaneous Sampling of Indoor and Outdoor Airborne Radioactivity after the Fukushima Daiichi Nuclear Power Plant Accident ... Large amts. of radioactive substances were released into the environment from the Fukushima Dai-ichi Nuclear Power Plants in eastern Japan as a consequence of the great earthquake (M 9.0) and tsunami of 11 March 2011. ... Proceedings of the International Symposium on Environmental Monitoring and Dose Estimation of Residents after Accident of TEPCO’s Fukushima Daiichi Nuclear Power Station; Shiran Hall, Kyoto, Japan, Dec 14, 2012; http://www.rri.kyoto-u.ac.jp/anzen_kiban/outcome/. ...

Tetsuo Ishikawa; Atsuyuki Sorimachi; Hideki Arae; Sarata Kumar Sahoo; Miroslaw Janik; Masahiro Hosoda; Shinji Tokonami

2014-01-22T23:59:59.000Z

431

Long-Term Characterization of Indoor and Outdoor Ultrafine Particles at a Commercial Building  

Science Journals Connector (OSTI)

Particle size distributions between 10 and 500 nm were measured both indoor and outdoor simultaneously using a wide-range particle spectrometer (WPS, model M-1000XP, MSP Inc.). ... This work was supported by the U.S. Environmental Protection Agency (EPA) through Science to Achieve Results (STAR) grant RD83107801, a Syracuse Center of Excellence CARTI project award, which is supported by a grant from the U.S. Environmental Protection Agency [award X-83232501-0], the Electric Power Research Institute under agreement W06325, and the New York State Energy Research and Development Authority (NYSERDA) through contracts 8650 and 10604. ...

Yungang Wang; Philip K. Hopke; David C. Chalupa; Mark J. Utell

2010-06-30T23:59:59.000Z

432

A life cycle comparison of greenhouse emissions for power generation from coal mining and underground coal gasification  

Science Journals Connector (OSTI)

For the emissions from energy and equipment use of underground coal mining, the data from the office of Energy Efficiency and Renewable Energy’s (EERE) hypothetical eastern U.S. underground coalmine is used (EERE

Zeshan Hyder; Nino S. Ripepi…

2014-05-01T23:59:59.000Z

433

Evaluating the Effects of Underground Nuclear Testing Below the Water Table on Groundwater and Radionuclide Migration in the  

E-Print Network (OSTI)

Evaluating the Effects of Underground Nuclear Testing Below the Water Table on Groundwater, using FEHM, evaluate perturbed groundwater behavior associated with underground nuclear tests to an instantaneous pressurization event caused by a nuclear test when different permeability and porosity

434

GRR/Section 18-UT-a - Underground Storage Tank | Open Energy Information  

Open Energy Info (EERE)

GRR/Section 18-UT-a - Underground Storage Tank GRR/Section 18-UT-a - Underground Storage Tank < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 18-UT-a - Underground Storage Tank 18UTAUndergroundStorageTank (1).pdf Click to View Fullscreen Contact Agencies Utah Department of Environmental Quality Regulations & Policies Utah Underground Storage Tank Act Triggers None specified Click "Edit With Form" above to add content 18UTAUndergroundStorageTank (1).pdf Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Flowchart Narrative Utah Department of Environmental Quality Division of Environmental Response and Remediation oversees the underground storage tank (UST) program in

435

The Strip and Underground Mine Siting Act (Montana) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Strip and Underground Mine Siting Act (Montana) The Strip and Underground Mine Siting Act (Montana) The Strip and Underground Mine Siting Act (Montana) < Back Eligibility Utility Investor-Owned Utility Industrial Construction Municipal/Public Utility Installer/Contractor Rural Electric Cooperative Program Info State Montana Program Type Siting and Permitting Provider Montana Department of Environmental Quality The policy of the state is to provide adequate remedies to protect the environmental life support system from degradation and to prevent unreasonable depletion and degradation of natural resources from strip and underground mining. This Act grants the Department of Environmental Quality the authority to review and approve or disapprove new strip-mine and new underground-mine site locations and reclamation plans and to adopt relevant

436

GRR/Section 18-TX-a - Underground Storage Tank Process | Open Energy  

Open Energy Info (EERE)

TX-a - Underground Storage Tank Process TX-a - Underground Storage Tank Process < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 18-TX-a - Underground Storage Tank Process 18TXAUndergroundStorageTanks (1).pdf Click to View Fullscreen Contact Agencies Texas Commission on Environmental Quality Regulations & Policies 30 Texas Administrative Code 334 - Underground and Aboveground Storage Tanks 30 Texas Administrative Code 37 - Financial Assurance for Petroleum Underground Storage Tanks Triggers None specified Click "Edit With Form" above to add content 18TXAUndergroundStorageTanks (1).pdf Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range.

437

Last U.S. Underground Nuclear Test Conducted | National Nuclear Security  

NLE Websites -- All DOE Office Websites (Extended Search)

U.S. Underground Nuclear Test Conducted | National Nuclear Security U.S. Underground Nuclear Test Conducted | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > About Us > Our History > NNSA Timeline > Last U.S. Underground Nuclear Test Conducted Last U.S. Underground Nuclear Test Conducted September 23, 1992 USA Last U.S. Underground Nuclear Test Conducted

438

Last U.S. Underground Nuclear Test Conducted | National Nuclear Security  

National Nuclear Security Administration (NNSA)

U.S. Underground Nuclear Test Conducted | National Nuclear Security U.S. Underground Nuclear Test Conducted | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > About Us > Our History > NNSA Timeline > Last U.S. Underground Nuclear Test Conducted Last U.S. Underground Nuclear Test Conducted September 23, 1992 USA Last U.S. Underground Nuclear Test Conducted

439

A Large Underground Liquid Argon Detector without a Cryostat? Kirk T McDonald (kirkmcd@princeton.edu)  

E-Print Network (OSTI)

, fabrication of this type of tank in an underground cavern is likely to be prohibitively expensive. Here, we

McDonald, Kirk

440

Solid-State Lighting: LED Lighting Facts  

NLE Websites -- All DOE Office Websites (Extended Search)

Market-Based Programs Printable Version Share this resource Send a link to Solid-State Lighting: LED Lighting Facts to someone by E-mail Share Solid-State Lighting: LED Lighting Facts on Facebook Tweet about Solid-State Lighting: LED Lighting Facts on Twitter Bookmark Solid-State Lighting: LED Lighting Facts on Google Bookmark Solid-State Lighting: LED Lighting Facts on Delicious Rank Solid-State Lighting: LED Lighting Facts on Digg Find More places to share Solid-State Lighting: LED Lighting Facts on AddThis.com... LED Lighting Facts CALiPER Program Standards Development Technical Information Network Gateway Demonstrations Municipal Consortium Design Competitions LED Lighting Facts LED lighting facts - A Program of the U.S. DOE DOE's LED Lighting Facts® program showcases LED products for general

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Performance Stabilization of CdTe PV Modules using Bias and Light  

SciTech Connect

Reversible performance changes due to light exposure frustrate repeatable performance measurements on CdTe PV modules. It is common to use extended light-exposure to ensure that measurements are representative of outdoor performance. We quantify the extent to which such a light-exposed state depends on module temperature and consider bias in the dark to aid in stabilization. We evaluate the use of dark forward bias to bring about a performance state equivalent to that obtained with light exposure, and to maintain a light-exposed state prior to STC performance measurement. Our results indicate that the most promising method for measuring a light-exposed state is to use light exposure at controlled temperature followed by prompt STC measurement with a repeatable time interval between exposure and the STC measurement.

Silverman, T. J.; Deceglie, M. G.; Marion, B.; Kurtz, S. R.

2014-07-01T23:59:59.000Z

442

Experiment Profile: COUPP NAME: Chicagoland Observatory for Underground Particle  

NLE Websites -- All DOE Office Websites (Extended Search)

COUPP COUPP NAME: Chicagoland Observatory for Underground Particle Physics, or COUPP WHAT WILL THIS TELL US ABOUT THE WORLD? Everything you see, visible matter, makes up 4 percent of the universe. Dark matter and dark energy makes up the rest of the universe. Physicists understand that dark matter acts as an invisible source of gravity, but little more. COUPP seeks to pinpoint what particles make up dark matter, which will help explain how the universe came to exist. Without the added gravitational attraction of dark matter, stars and galaxies would never have formed. The expansion of the universe after the Big Bang would have dispersed visible matter too quickly. WHY IS THIS EXPERIMENT NEEDED NOW? Physicists have narrowed the hunt for what particles constitute dark

443

Thermophysical models of underground coal gasification and FEM analysis  

SciTech Connect

In this study, mathematical models of the coupled thermohydromechanical process of coal rock mass in an underground coal gasification panel are established. Combined with the calculation example, the influence of heating effects on the observed values and simulated values for pore water pressure, stress, and displacement in the gasification panel are fully discussed and analyzed. Calculation results indicate that 38, 62, and 96 days after the experiment, the average relative errors for the calculated values and measured values for the temperature and water pressure were between 8.51-11.14% and 3-10%, respectively; with the passage of gasification time, the calculated errors for the vertical stress and horizontal stress gradually declined, but the simulated errors for the horizontal and vertical displacements both showed a rising trend. On the basis of the research results, the calculated values and the measured values agree with each other very well.

Yang, L.H. [China University of Mining & Technology, Xuzhou (China)

2007-11-15T23:59:59.000Z

444

Diesel exhaust emissions from engines for use in underground mines  

SciTech Connect

Experimental data were obtained from two medium-duty diesel engines derated to qualify for use in underground mines. Gaseous and particulate emissions from these engines were measured and results provide information on the effect of exhaust treatment devices on the emissions. The devices in the study were a catalyst, a particulate trap, and an exhaust gas cooler of the water scrubber type. Emission levels of carbon monoxide and hydrocarbons were observed to be very low in comparison with emission levels of comparable engines in full-rated operation. Oxides of nitrogen and benzo(a)pyrene content of the exhaust also were found to be somewhat low in comparison with previous findings. For particulate reduction, the combination of a particulate trap and a scrubber was observed to be the most effective combination tried; in some cases, over 60% particulate reduction was effected by the trap-scrubber combination.

Eccleston, B.H.; Seizinger, D.E.; Clingenpeel, J.M.

1981-04-01T23:59:59.000Z

445

Proceedings of the ninth annual underground coal gasification symposium  

SciTech Connect

The Ninth Underground Coal Gasification Symposium was held August 7 to 10, 1983 at the Indian Lakes Resort and Conference Center in Bloomingdale, Illinois. Over one-hundred attendees from industry, academia, National Laboratories, State Government, and the US Government participated in the exchange of ideas, results and future research plans. Representatives from six countries including France, Belgium, United Kingdom, The Netherlands, West Germany, and Brazil also participated by presenting papers. Fifty papers were presented and discussed in four formal sessions and two informal poster sessions. The presentations described current and future field testing plans, interpretation of field test data, environmental research, laboratory studies, modeling, and economics. All papers were processed for inclusion in the Energy Data Base.

Wieber, P.R.; Martin, J.W.; Byrer, C.W. (eds.)

1983-12-01T23:59:59.000Z

446

Underground Storage Tank Integrated Demonstration (UST-ID). Technology summary  

SciTech Connect

The DOE complex currently has 332 underground storage tanks (USTs) that have been used to process and store radioactive and chemical mixed waste generated from weapon materials production. Very little of the over 100 million gallons of high-level and low-level radioactive liquid waste has been treated and disposed of in final form. Two waste storage tank design types are prevalent across the DOE complex: single-shell wall and double-shell wall designs. They are made of stainless steel, concrete, and concrete with carbon steel liners, and their capacities vary from 5000 gallons (19 m{sup 3}) to 10{sup 6} gallons (3785 m{sup 3}). The tanks have an overburden layer of soil ranging from a few feet to tens of feet. Responding to the need for remediation of tank waste, driven by Federal Facility Compliance Agreements (FFCAs) at all participating sites, the Underground Storage Tank Integrated Demonstration (UST-ID) Program was created by the US DOE Office of Technology Development in February 1991. Its mission is to focus the development, testing, and evaluation of remediation technologies within a system architecture to characterize, retrieve, treat to concentrate, and dispose of radioactive waste stored in USTs at DOE facilities. The ultimate goal is to provide safe and cost-effective solutions that are acceptable to the public and the regulators. The UST-ID has focused on five DOE locations: the Hanford Site, which is the host site, in Richland, Washington; the Fernald Site in Fernald, Ohio; the Idaho National Engineering Laboratory near Idaho Falls, Idaho; the Oak Ridge Reservation in Oak Ridge, Tennessee, and the Savannah River Site in Savannah River, South Carolina.

Not Available

1994-02-01T23:59:59.000Z

447

Using the recreation opportunity spectrum to evaluate the temporal impacts of timber harvesting on outdoor recreation settings  

Science Journals Connector (OSTI)

Abstract Sustainable forest management certification is an important development in forestry. It requires the evaluation of forest management plans, including recreation outcomes, to assess their performance over time. This poses a challenge for jurisdictions that do not have reliable data about outdoor recreation participation. In the absence of such data, and in management environments constrained by limited resources, a pragmatic tool is needed to measure and forecast outdoor recreation settings and opportunities. We quantify the impact of forest management activities on recreation opportunities based on the use of an existing management tool, the recreation opportunity spectrum (ROS). We describe the development and testing of a new GIS-based approach to delineate ROS classes from potential timber harvesting activities, and identify potential impacts of forest harvesting activities on recreation settings. This application of a temporally dynamic, spatially explicit approach allows us to measure the diversity of recreation settings and to evaluate the impacts of timber harvesting on recreation opportunities. A comparison of two forest management scenarios suggests that, without a priori identification and protection of vulnerable ROS classes, primitive settings may be systematically lost over time. Management implications This paper presents a novel method for assessing the diversity of outdoor recreation settings in a commercial forest using a temporally dynamic application of the recreation opportunity spectrum (ROS). The advantages for management are the following:• The method enables the evaluation of different forest management scenarios and their effects on outdoor recreation for various defined planning horizons. • It enables managers to integrate outdoor recreation settings into planning at a very early stage. • It facilitates the integration of outdoor recreation into certification processes such as SFM. • The method is particularly useful in large areas of managed forests that lack quality data about outdoor recreation use and characteristics, but are committed to the maintenance of backcountry condition, because the approach is able to quantify and forecast outdoor recreation settings and associated opportunities. The addition of the temporal element achieves this and addresses one of the main criticisms of the ROS.

H.W. Harshaw; S.R.J. Sheppard

2013-01-01T23:59:59.000Z

448

Relationships between forest management policies and outdoor recreation opportunities supplied on private forest lands in East Texas  

E-Print Network (OSTI)

RKLAT10NSHIPS BET( EEN FOyugST K'. NAGENENT POLICIES AND OUTDOOR P"CREATION OPPORTUNITIES SUPPLIED ON PRIVATE FOREST IJNDS IN EAST TEXAS A Thcsi. s RENNETIi NAFNE PRESTR13GE Submitted to the Graduate College of the Texas A&N Un i ve rs ity... in partial fulfillment of the require sents for the degree of BASTER OF SCIENCF, Nay 1968 Najor Subject: Range Sc! ence (Recreation and Parks) RELATIONSHIPS BETWEEN FOREST MANAGEMENT POLICIES AND OUTDOOR RECREATION OPPORTUNITIES SUPPLIED ON PRIVATE...

Prestridge, Kenneth Wayne

1968-01-01T23:59:59.000Z

449

Direct Analysis of JV-Curves Applied to an Outdoor-Degrading CdTe Module (Presentation)  

SciTech Connect

We present the application of a phenomenological four parameter equation to fit and analyze regularly measured current density-voltage JV curves of a CdTe module during 2.5 years of outdoor operation. The parameters are physically meaningful, i.e. the short circuit current density Jsc, open circuit voltage Voc and differential resistances Rsc, and Roc. For the chosen module, the fill factor FF degradation overweighs the degradation of Jsc and Voc. Interestingly, with outdoor exposure, not only the conductance at short circuit, Gsc, increases but also the Gsc(Jsc)-dependence. This is well explained with an increase in voltage dependent charge carrier collection in CdTe.

Jordan, D; Kurtz, S.; Ulbrich, C.; Gerber, A.; Rau, U.

2014-03-01T23:59:59.000Z

450

Lai, D., Guo, D., Hou, Y., Lin, C., and Chen, Q. 2014. "Studies of Outdoor Thermal Comfort in Northern China," Building and Environment, 77, 110-118  

E-Print Network (OSTI)

. In addition, revitalizing outdoor spaces will lead to energy saving inside buildings. As people spend more in Northern China," Building and Environment, 77, 110-118 Studies of Outdoor Thermal Comfort in Northern China comfort, while the Predicted Mean Vote (PMV) overestimated it. The neutral Physiological Equivalent

Chen, Qingyan "Yan"

451

,"AGA Producing Region Natural Gas Underground Storage Volume (MMcf)"  

U.S. Energy Information Administration (EIA) Indexed Site

Region Natural Gas Underground Storage Volume (MMcf)" Region Natural Gas Underground Storage Volume (MMcf)" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","AGA Producing Region Natural Gas Underground Storage Volume (MMcf)",1,"Monthly","9/2013" ,"Release Date:","12/12/2013" ,"Next Release Date:","1/7/2014" ,"Excel File Name:","n5030872m.xls" ,"Available from Web Page:","http://tonto.eia.gov/dnav/ng/hist/n5030872m.htm" ,"Source:","Energy Information Administration" ,"For Help, Contact:","infoctr@eia.doe.gov"

452

,"AGA Eastern Consuming Region Natural Gas Underground Storage Volume (MMcf)"  

U.S. Energy Information Administration (EIA) Indexed Site

Eastern Consuming Region Natural Gas Underground Storage Volume (MMcf)" Eastern Consuming Region Natural Gas Underground Storage Volume (MMcf)" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","AGA Eastern Consuming Region Natural Gas Underground Storage Volume (MMcf)",1,"Monthly","9/2013" ,"Release Date:","12/12/2013" ,"Next Release Date:","1/7/2014" ,"Excel File Name:","n5030882m.xls" ,"Available from Web Page:","http://tonto.eia.gov/dnav/ng/hist/n5030882m.htm" ,"Source:","Energy Information Administration" ,"For Help, Contact:","infoctr@eia.doe.gov"

453

,"AGA Western Consuming Region Natural Gas Underground Storage Volume (MMcf)"  

U.S. Energy Information Administration (EIA) Indexed Site

Western Consuming Region Natural Gas Underground Storage Volume (MMcf)" Western Consuming Region Natural Gas Underground Storage Volume (MMcf)" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","AGA Western Consuming Region Natural Gas Underground Storage Volume (MMcf)",1,"Monthly","9/2013" ,"Release Date:","12/12/2013" ,"Next Release Date:","1/7/2014" ,"Excel File Name:","n5030892m.xls" ,"Available from Web Page:","http://tonto.eia.gov/dnav/ng/hist/n5030892m.htm" ,"Source:","Energy Information Administration" ,"For Help, Contact:","infoctr@eia.doe.gov"

454

Thermal characterisation of a lightweight mortar containing expanded perlite for underground insulation  

Science Journals Connector (OSTI)

This paper aims to investigate the use of expanded perlite in mortar, for further application of shotcrete to thermal insulation of underground mines. Mixes were designed according to the typical proportions of underground shotcrete, with the sand volumetrically substituted by expanded perlite. Tests of samples were conducted at four ages. Transient plane source technique was utilised to measure the thermal properties. The results showed reduced weight, decreased thermal conductivity, deteriorated thermal diffusivity, and sacrificed mechanical strength with perlite addition. Experimental data analysis and explanation in this paper would establish useful fundamentals for further application of expanded perlite to underground shotcrete.

W.V. Liu; D.B. Apel; V. Bindiganavile

2011-01-01T23:59:59.000Z

455

,"U.S. Working Natural Gas Total Underground Storage Capacity (MMcf)"  

U.S. Energy Information Administration (EIA) Indexed Site

Total Underground Storage Capacity (MMcf)" Total Underground Storage Capacity (MMcf)" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","U.S. Working Natural Gas Total Underground Storage Capacity (MMcf)",1,"Annual",2012 ,"Release Date:","12/12/2013" ,"Next Release Date:","1/7/2014" ,"Excel File Name:","nga_epg0_sacw0_nus_mmcfa.xls" ,"Available from Web Page:","http://tonto.eia.gov/dnav/ng/hist/nga_epg0_sacw0_nus_mmcfa.htm" ,"Source:","Energy Information Administration" ,"For Help, Contact:","infoctr@eia.doe.gov"

456

Light's twist  

Science Journals Connector (OSTI)

...Glasgow G12 8QQ, UK An invited Perspective to mark the election of Miles Padgett to the fellowship of the Royal Society in 2014. That...energy and momentum flow within light beams can twist to form vortices such as eddies in a stream. These...

2014-01-01T23:59:59.000Z

457

Trial Demonstration of Area Lighting Retrofit: Yuma Border Patrol, Yuma Arizona  

SciTech Connect

The Yuma Sector Border Patrol Area is a high flux lighting application in a high temperature environment, presenting a formidable challenge for light-emitting diodes (LEDs). This retrofit is an Energy Savings Performance Contract ENABLE project under the U.S. Department of Energy (DOE) Federal Energy Management Program. If high flux LED technology performs well in a region with high ambient temperature and solar radiation, it can perform well in most outdoor environments. The design process for the Yuma retrofit has already provided valuable knowledge to CBP and DOE. The LED lighting system selected for the retrofit is expected to reduce energy consumption 69% compared to the incumbent quartz metal halide (QMH) lighting system. If the LED lighting system is installed, GATEWAY will continue to document and disseminate information regarding the installation and long-term performance so that others may also gain valuable knowledge from the Yuma Sector Border Patrol Area lighting retrofit.

Wilkerson, Andrea M.; McCullough, Jeffrey J.

2014-12-30T23:59:59.000Z

458

Piazza del Marchese Paolo: An architectural and soundscape design to redevelop an outdoor public space  

Science Journals Connector (OSTI)

This paper will report about a design procedure regarding the redevelopment of an open square located in the historical center of Città di Castello Italy. The square has five entrances and it is surrounded by old buildings. The Public Library of the town is also located at this place. Currently the square is used as a parking lot. The goal of the design is to redevelop this square matching the given context. For the design procedure first the visual and acoustical status of the place will be described. Second binaural recordings will be carried out to measure the acoustical climate and third soundwalks will be conducted to help to detect the soundmarks of the area. Moreover the idea is to transform the space in a pedestrian area and to consider the square as an acoustical “outdoor floor” for the library. The design process will be focused on the preservation of the genuine Soundscape.

Achille Sberna; Francesco Asdrubali; Brigitte Schulte-Fortkamp

2011-01-01T23:59:59.000Z

459

Measuring the Optical Performance of Evacuated Receivers via an Outdoor Thermal Transient Test: Preprint  

SciTech Connect

Modern parabolic trough solar collectors operated at high temperatures to provide the heat input to Rankine steam power cycles employ evacuated receiver tubes along the collector focal line. High performance is achieved via the use of a selective surface with a high absorptance for incoming short-wave solar radiation and a low emittance for outgoing long-wave infrared radiation, as well as the use of a hard vacuum to essentially eliminate convective and conductive heat losses. This paper describes a new method that determines receiver overall optical efficiency by exposing a fluid-filled, pre-cooled receiver to one sun outdoors and measuring the slope of the temperature curve at the point where the receiver temperature passes the glass envelope temperature (that is, the point at which there is no heat gain or loss from the absorber). This transient test method offers the potential advantages of simplicity, high accuracy, and the use of the actual solar spectrum.

Kutscher, C.; Burkholder, F.; Netter, J.

2011-08-01T23:59:59.000Z

460

Measurement and analysis of evaporation from an inactive outdoor swimming pool  

SciTech Connect

Evaporation rates and total energy loads from an unoccupied, heated, outdoor pool in Fort Collins, Colorado were investigated. Pool and air temperatures, humidity, thermal radiation, wind speed, and water loss due to evaporation were measured over 21 test periods ranging from 1.1 to 16.2 hours during August and September, 1992. Data were analyzed and compared to commonly used evaporation rate equations, most notably that used in the ASHRAE Applications Handbook. Measured evaporation was 72% of the ASHRAE calculated value with near-zero wind velocity, and 82% of the ASHRAE value at 2.2 m/s wind velocity. A modified version of the ASHRAE equation was developed. Two overnight tests showed energy loss of 56% by evaporation, 26% by radiation, and 18% by convection. A correlation between radiation loss and temperatures was also found for the range of test conditions.

Smith, C.C.; Loef, G. (Colorado State Univ., Fort Collins, CO (United States)); Jones, R. (Department of Energy, Golden (United States))

1994-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Outdoor field evaluation of passive tritiated water vapor samplers at Canadian power reactor sites  

SciTech Connect

Tritium is one of several radioactive nuclides routinely monitored in and around CANDU{reg_sign} (CANada Deuterium Uranium) power reactor facilities. Over the last ten years, passive samplers have replaced active sampling devices for sampling tritiated water vapor in the workplace at many CANDU stations. The potential of passive samplers for outdoor monitoring has also been realized. This paper presents the result of a 1-y field trial carried out at all five Canadian CANDU reactor sites. The results indicate that passive samplers can be used at most sampling locations to measure tritiated water vapor in air concentrations as low as 1 Bq m{sup -3} over a 30-d sampling period. Only in one of the five sampling locations was poor agreement observed between active and passive monitoring data. This location, however, was very windy and it is suspected that the gusty winds were the source of the discrepancies observed. 15 refs., 8 figs., 1 tab.

Wood, M.J. [Chalk River Lab., Chalk River, Ontario (Canada)

1996-02-01T23:59:59.000Z

462

Hybrid Indoor and Outdoor Tracking for Mobile 3D Mixed Reality Wayne Piekarski, Ben Avery, Bruce H. Thomas, Pierre Malbezin  

E-Print Network (OSTI)

Hybrid Indoor and Outdoor Tracking for Mobile 3D Mixed Reality Wayne Piekarski, Ben Avery, Bruce H@tinmith.net, bruce.thomas@unisa.edu.au, pierre@tinmith.net Abstract This paper describes a new hybrid tracking system, in most cases an arrow navigation cue and a hand held World-in-Miniature model are used to provide

Thomas, Bruce

463

A Mechanically Stable, Low Profile, Omni-Directional Solar-Cell Integrated Antenna for Outdoor Wireless Sensor Nodes  

E-Print Network (OSTI)

A Mechanically Stable, Low Profile, Omni-Directional Solar-Cell Integrated Antenna for Outdoor nodes have been integrated with solar cells to increase the robustness of the network [2]. To boost under the solar cell circuitry. Several solar antenna integration methods have been published

Tentzeris, Manos

464

Field Results from Application of the Outdoor-Air/Economizer Diagnostician for Commissioning and O&M  

SciTech Connect

This paper presents results of field testing an automated diagnostician for outdoor-air-supply and economizer systems that can be used for commissioning purposes. The fundamental capabilities of the tool are described and key results of its application on six air handlers in a large hotel building are discussed. Ancillary issues pertinent to the development and application of such tools are also presented.

Pratt, Robert G.; Katipamula, Srinivas; Brambley, Michael R.; Blanc, Steven L.

2000-05-31T23:59:59.000Z

465

Application of the Transmission Line Matrix method for outdoor sound propagation modelling Part 2: Experimental validation using  

E-Print Network (OSTI)

Application of the Transmission Line Matrix method for outdoor sound propagation modelling ­ Part 2 Received in revised form 9 July 2013 Accepted 23 July 2013 Keywords: Meso-NH Transmission Line Matrix model-domain acoustic model is based on the Transmission Line Matrix method. Its develop- ment has also been promoted

Ribes, Aurélien

466

Texas Electric Lighting Report  

NLE Websites -- All DOE Office Websites (Extended Search)

electric lighting electric lighting The SNAP House's lighting design aims for elegant simplicity in concept, use, and maintenance. Throughout the house, soft, ambient light is juxtaposed with bright, direct task lighting. All ambient and most task lighting is integrated directly into the architectural design of the house. An accent light wall between the bedroom and bathroom provides a glowing light for nighttime navigation.

467

Mapping cultural ecosystem services: A framework to assess the potential for outdoor recreation across the EU  

Science Journals Connector (OSTI)

Abstract Research on ecosystem services mapping and valuing has increased significantly in recent years. However, compared to provisioning and regulating services, cultural ecosystem services have not yet been fully integrated into operational frameworks. One reason for this is that transdisciplinarity is required to address the issue, since by definition cultural services (encompassing physical, intellectual, spiritual interactions with biota) need to be analysed from multiple perspectives (i.e. ecological, social, behavioural). A second reason is the lack of data for large-scale assessments, as detailed surveys are a main source of information. Among cultural ecosystem services, assessment of outdoor recreation can be based on a large pool of literature developed mostly in social and medical science, and landscape and ecology studies. This paper presents a methodology to include recreation in the conceptual framework for EU wide ecosystem assessments (Maes et al., 2013), which couples existing approaches for recreation management at country level with behavioural data derived from surveys and population distribution data. The proposed framework is based on three components: the ecosystem function (recreation potential), the adaptation of the Recreation Opportunity Spectrum framework to characterise the ecosystem service and the distribution of potential demand in the EU. Results show that 38% of the EU is characterised by a high outdoor recreation potential, which is easily accessible, and that such areas can host about 35.4% of potential demand for close-to-home trips (recreation potential as an ecosystem service to EU citizens, to describe through country profiles differences in ecosystem service provision at regional level, and can be used as an input to land use planning processes.

Maria Luisa Paracchini; Grazia Zulian; Leena Kopperoinen; Joachim Maes; Jan Philipp Schägner; Mette Termansen; Marianne Zandersen; Marta Perez-Soba; Paul A. Scholefield; Giovanni Bidoglio

2014-01-01T23:59:59.000Z

468

GRR/Elements/14-CA-c.3 - Application For Proposed Underground Injection  

Open Energy Info (EERE)

CA-c.3 - Application For Proposed Underground Injection CA-c.3 - Application For Proposed Underground Injection Project < GRR‎ | Elements Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections 14-CA-c.3 - Application For Proposed Underground Injection Project Under the Memorandum of Agreement Between State Water Resources Control Board and DOGGR geothermal operators must file an application for underground geothermal wastewater injection with the appropriate DOGGR district office. The application must include: A chemical analysis to characterize the proposed injection fluid; A chemical analysis from the proposed zone of injection considering the characteristics of the zone; and The depth, location, and injection formation of the proposed well. Logic Chain

469

GRR/Section 18-CO-a - Underground Storage Tank Permit | Open Energy  

Open Energy Info (EERE)

GRR/Section 18-CO-a - Underground Storage Tank Permit GRR/Section 18-CO-a - Underground Storage Tank Permit < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 18-CO-a - Underground Storage Tank Permit 18COAUndergroundStorageTankPermit (1).pdf Click to View Fullscreen Contact Agencies Colorado Department of Labor and Employment Regulations & Policies Solid Waste Disposal Act 7 CCR 1101-14 Article 2 Underground Storage Tanks Triggers None specified Click "Edit With Form" above to add content 18COAUndergroundStorageTankPermit (1).pdf Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Flowchart Narrative The design, installation, registration, construction, and operation of

470

Underground Storage of Carbon Dioxide-as a Solid | U.S. DOE Office of  

NLE Websites -- All DOE Office Websites (Extended Search)

Underground Storage of Carbon Dioxide-as a Solid Underground Storage of Carbon Dioxide-as a Solid Advanced Scientific Computing Research (ASCR) ASCR Home About Research Facilities Science Highlights Benefits of ASCR Funding Opportunities Advanced Scientific Computing Advisory Committee (ASCAC) News & Resources Contact Information Advanced Scientific Computing Research U.S. Department of Energy SC-21/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-7486 F: (301) 903-4846 E: sc.ascr@science.doe.gov More Information » July 2012 Underground Storage of Carbon Dioxide-as a Solid Nanoscale features in rocks enable more carbon dioxide to be trapped as a solid carbonate material underground. Print Text Size: A A A Subscribe FeedbackShare Page Click to enlarge photo. Enlarge Photo Image courtesy of Lawrence Berkeley National Laboratory

471

NNSA Commemorates the 20th Anniversary of the Last Underground Nuclear Test  

NLE Websites -- All DOE Office Websites (Extended Search)

the 20th Anniversary of the Last Underground Nuclear Test the 20th Anniversary of the Last Underground Nuclear Test | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > Media Room > Video Gallery > NNSA Commemorates the 20th Anniversary of the ... NNSA Commemorates the 20th Anniversary of the Last Underground Nuclear Test NNSA Commemorates the 20th Anniversary of the Last Underground Nuclear Test

472

GRR/Section 18-NV-a - Underground Storage Tank | Open Energy Information  

Open Energy Info (EERE)

a - Underground Storage Tank a - Underground Storage Tank < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 18-NV-a - Underground Storage Tank 18NVAUndergroundStorageTank.pdf Click to View Fullscreen Contact Agencies Nevada Division of Environmental Protection Regulations & Policies Nevada Revised Statutes (NRS) Nevada Administrative Code (NAC) Triggers None specified Click "Edit With Form" above to add content 18NVAUndergroundStorageTank.pdf Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Flowchart Narrative The Nevada Division of Environmental Protection (NDEP) administers the Underground Storage Tank (UST) Program for the State of Nevada.

473

DOE to host workshop to explore use of WIPP as 'next generation' underground laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

Workshop to Explore Use of WIPP Workshop to Explore Use of WIPP As 'Next Generation' Underground Laboratory CARLSBAD, N.M., June 9, 2000 - The U.S. Department of Energy's (DOE) Carlsbad Area Office is sponsoring the "Workshop on the Next Generation U.S. Underground Science Facility" June 12-14 at the Pecos River Village Conference Center, 711 Muscatel, in Carlsbad. The purpose of the workshop is to explore the potential use of the DOE's Waste Isolation Pilot Plant (WIPP) underground as a next generation laboratory for conducting nuclear and particle astrophysics and other basic science research, and how that might be accomplished. "WIPP's underground environment represents one of only a few choices open to the research community for siting experiments that require shielding from cosmic rays," said Dr.

474

,"U.S. Underground Natural Gas Storage Capacity"  

U.S. Energy Information Administration (EIA) Indexed Site

3,"Monthly","9/2013","1/15/1989" 3,"Monthly","9/2013","1/15/1989" ,"Release Date:","12/12/2013" ,"Next Release Date:","1/7/2014" ,"Excel File Name:","ng_stor_cap_dcu_nus_m.xls" ,"Available from Web Page:","http://www.eia.gov/dnav/ng/ng_stor_cap_dcu_nus_m.htm" ,"Source:","Energy Information Administration" ,"For Help, Contact:","infoctr@eia.gov" ,,"(202) 586-8800",,,"12/12/2013 7:03:21 PM" "Back to Contents","Data 1: U.S. Underground Natural Gas Storage Capacity" "Sourcekey","N5290US2","NGA_EPG0_SACW0_NUS_MMCF","NA1394_NUS_8" "Date","U.S. Total Natural Gas Underground Storage Capacity (MMcf)","U.S. Working Natural Gas Total Underground Storage Capacity (MMcf)","U.S. Natural Gas Count of Underground Storage Capacity (Count)"

475

GRR/Section 18-MT-a - Underground Storage Tanks | Open Energy Information  

Open Energy Info (EERE)

MT-a - Underground Storage Tanks MT-a - Underground Storage Tanks < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 18-MT-a - Underground Storage Tanks 18MTAUndergroundStorageTanks (2).pdf Click to View Fullscreen Contact Agencies Montana Department of Environmental Quality Regulations & Policies Montana Code Annotated 75-11-501 Administrative Rules of Montana 17-56 Triggers None specified Click "Edit With Form" above to add content 18MTAUndergroundStorageTanks (2).pdf Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Flowchart Narrative A developer must obtain an Underground Storage Tank Installation Permit

476

GRR/Section 18-ID-a - Underground Storage Tank Systems | Open Energy  

Open Energy Info (EERE)

GRR/Section 18-ID-a - Underground Storage Tank Systems GRR/Section 18-ID-a - Underground Storage Tank Systems < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 18-ID-a - Underground Storage Tank Systems 18IDAUndergroundStorageTankSystems.pdf Click to View Fullscreen Contact Agencies Idaho Department of Environmental Quality Regulations & Policies IDAPA 58.01.07 Rules Regulating Underground Storage Tank Systems Triggers None specified Click "Edit With Form" above to add content 18IDAUndergroundStorageTankSystems.pdf Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Flowchart Narrative The Idaho Department of Environmental Quality (DEQ) requires notification

477

IDAPA 58.01.07 - Rules Regulating Underground Storage Tank Systems...  

Open Energy Info (EERE)

Rules Regulating Underground Storage Tank Systems Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- StatuteStatute: IDAPA 58.01.07 - Rules...

478

UC 19-6-401 et seq. - Utah Underground Storage Tank Act | Open...  

Open Energy Info (EERE)

UC 19-6-401 et seq. - Utah Underground Storage Tank Act Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- StatuteStatute: UC 19-6-401 et seq. -...

479

Field Study on PM1 Air Pollution in a Residential Underground Parking Lot  

Science Journals Connector (OSTI)

PM1 (fine particles with a diameter smaller than 1 ?m) number concentrations are more straightforward compared with particle mass concentrations for air quality assessment in underground parking lots. PM1 ... PM1...

Yu Zhao; Jianing Zhao

2014-01-01T23:59:59.000Z

480

Preliminary Notice of Violation, Pacific Underground Construction, Inc.- WEA-2009-02  

Energy.gov (U.S. Department of Energy (DOE))

Issued to Pacific Underground Construction, Inc. related to a polyvinyl chloride (PVC) pipe explosion that occurred in Sector 30 of the linear accelerator facility at the SLAC National Accelerator Laboratory (SLAC).

Note: This page contains sample records for the topic "outdoor lighting underground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

MCA 75-11-501 et seq. - Montana Underground Storage Tank Act...  

Open Energy Info (EERE)

ActLegal Abstract Sets forth statutory requirements for regulating underground storage tanks. Published NA Year Signed or Took Effect 1997 Legal Citation 75-11-501 et seq., MCA...

482

7 C.C.R. 1101-14 - Underground Storage Tanks and Aboveground...  

Open Energy Info (EERE)

1101-14 - Underground Storage Tanks and Aboveground Storage tanks Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- RegulationRegulation: 7 C.C.R....

483

OAR 340-150 - DEQ Underground Storage Tank Rules | Open Energy...  

Open Energy Info (EERE)

Storage Tank RulesLegal Abstract Provide for the regulation of underground storage tanks. Published NA Year Signed or Took Effect 2003 Legal Citation OAR 340-150 (1990) DOI...

484

Modelling rock–water interactions in flooded underground coal mines, Northern Appalachian Basin  

Science Journals Connector (OSTI)

...Office of Surface Mining 3 Parkway Center...flooded underground coal mines in northern Appalachia, USA. In early...the Effects of Coal Mining, Greene County...Seam of Northern Appalachia. In: Proceedings Eastern Coal Mine Geomechanics...

Eric F. Perry

485

Head of EM Visits Waste Isolation Pilot Plant for First Underground...  

Office of Environmental Management (EM)

Secretary Mark Whitney today visited the Waste Isolation Pilot Plant (WIPP) near Carlsbad, N.M., where he became the first non-WIPP employee to tour the underground facility...

486

EA-1219: Hoe Creek Underground Coal Gasification Test Site Remediation, Campbell County, Wyoming  

Energy.gov (U.S. Department of Energy (DOE))

This EA evaluates the environmental impacts for the proposed Hoe Creek Underground Coal Gasification Test Site Remediation that would be performed at the Hoe Creek site in Campbell County, Wyoming.

487

Thermal Imaging of Vegetation to Detect CO2 Gas Leaking From Underground  

Science Journals Connector (OSTI)

Thermal imaging of vegetation has been used to detect CO2 gas leaking from an underground gas reservoir. Plant stress caused by increased soil gas concentration results in warmer...

Shaw, Joseph A; Johnson, Jennifer E; Lawrence, Rick; Nugent, Paul W

488

Assessment of ground subsidence hazard near an abandoned underground coal mine using GIS  

Science Journals Connector (OSTI)

This study constructs a hazard map for ground subsidence around abandoned underground coal mines (AUCMs) at Samcheok City in ... ) model, and a Geographic Information System (GIS). To evaluate the factors related...

Ki-Dong Kim; Saro Lee; Hyun-Joo Oh; Jong-Kuk Choi; Joong-Sun Won

2006-09-01T23:59:59.000Z

489

INDUCED SEISMICITY MONITORING OF AN UNDERGROUND SALT CAVITY UNDER A TRANSIENT PRESSURE EXPERIMENT  

E-Print Network (OSTI)

to 125 m in cemented boreholes drilled in thé vicinity of thé study area. The underground cavity under and Monitoring, Seismic Introduction A large research project within thé GISOS1 program has been launched

Paris-Sud XI, Université de

490

Tectonic Strain Release by Underground Nuclear Explosions and its Effect on Seismic Discrimination  

Science Journals Connector (OSTI)

......patterns to geologic structure in Yucca Flats Nevada Test Site, in Nevada Test Site, ed. Eckel E. B., Geol. Soc. Am. Mem...of the Benham underground nuclear explosion, Nevada Test Site, Bull. seism. Soc. Am., 59, 2209-2220......

M. Nafi Toksöz; Harold H. Kehrer

1972-12-01T23:59:59.000Z

491

SURVEY OF EXISTING UNDERGROUND OPENINGS FOR IN-SITU EXPERIMENTAL FACILITIES  

E-Print Network (OSTI)

layouts of underground powerhouse Figure 2. Figure 3. FigureG' adit accessible fro? powerhouse deck, through 4 x 7 f tU.S. Corps of Engineers powerhouse facilities offer possible

Wollenberg, H.

2010-01-01T23:59:59.000Z

492

Dynamic underground stripping: steam and electric heating for in situ decontamination of soils and groundwater  

DOE Patents (OSTI)

A dynamic underground stripping process removes localized underground volatile organic compounds from heterogeneous soils and rock in a relatively short time. This method uses steam injection and electrical resistance heating to heat the contaminated underground area to increase the vapor pressure of the contaminants, thus speeding the process of contaminant removal and making the removal more complete. The injected steam passes through the more permeable sediments, distilling the organic contaminants, which are pumped to the surface. Large electrical currents are also applied to the contaminated area, which heat the impermeable subsurface layers that the steam has not penetrated. The condensed and vaporized contaminants are withdrawn by liquid pumping and vacuum extraction. The steam injection and electrical heating steps are repeated as necessary. Geophysical imaging methods can be used to map the boundary between the hot, dry, contamination-free underground zone and the cool, damp surrounding areas to help monitor the dynamic stripping process. 4 figs.

Daily, W.D.; Ramirez, A.L.; Newmark, R.L.; Udell, K.; Buetnner, H.M.; Aines, R.D.

1995-09-12T23:59:59.000Z

493

Measurement of Cosmic Ray Flux in China JinPing underground Laboratory  

E-Print Network (OSTI)

China JinPing underground Laboratory (CJPL) is the deepest underground laboratory presently running in the world. In such a deep underground laboratory, the cosmic ray flux is a very important and necessary parameter for rare event experiments. A plastic scintillator telescope system has been set up to measure the cosmic ray flux. The performance of the telescope system has been studied using the cosmic ray on the ground laboratory near CJPL. Based on the underground experimental data taken from November 2010 to December 2011 in CJPL, which has effective live time of 171 days, the cosmic ray muon flux in CJPL is measured to be (2.0+-0.4)*10^(-10)/(cm^2)/(s). The ultra-low cosmic ray background guarantees CJPL's ideal environment for dark matter experiment.

Wu, Yu-Cheng; Yue, Qian; LI, Yuan-Jing; Cheng, Jian-Ping; Kang, Ke-Jun; Chen, Yun-Hua; Li, Jin; Li, Jian-Min; Li, Yu-Lan; Liu, Shu-Kui; Ma, Hao; Ren, Jin-Bao; Shen, Man-Bin; Wang, Ji-Min; Wu, Shi-Yong; Xue, Tao; YI, Nan; Zeng, Xiong-Hui; Zeng, Zhi; Zhu, Zhong-Hua

2013-01-01T23:59:59.000Z

494

Measurement of cosmic ray flux in the China JinPing underground laboratory  

Science Journals Connector (OSTI)

The China JinPing underground Laboratory (CJPL) is the deepest underground laboratory running in the world at present. In such a deep underground laboratory, the cosmic ray flux is a very important and necessary parameter for rare-event experiments. A plastic scintillator telescope system has been set up to measure the cosmic ray flux. The performance of the telescope system has been studied using the cosmic rays on the ground laboratory near the CJPL. Based on the underground experimental data taken from November 2010 to December 2011 in the CJPL, which has an effective live time of 171 days, the cosmic ray muon flux in the CJPL is measured to be (2.0±0.4)?10?10/(cm2s). The ultra-low cosmic ray background guarantees an ideal environment for dark matter experiments at the CJPL.

Wu Yu-Cheng (???); Hao Xi-Qing (???); Yue Qian (??); Li Yuan-Jing (???); Cheng Jian-Ping (???); Kang Ke-Jun (???); Chen Yun-Hua (???); Li Jin (??); Li Jian-Min (???); Li Yu-Lan (???); Liu Shu-Kui (???); Ma Hao (??); Ren Jin-Bao (???); Shen Man-Bin (???); Wang Ji-Min (???); Wu Shi-Yong (???); Xue Tao (??); Yi Nan (??); Zeng Xiong-Hui (???); Zeng Zhi (??); Zhu Zhong-Hua (???)

2013-01-01T23:59:59.000Z

495

U.S. Underground Natural Gas Storage Developments: 1998-2005  

U.S. Energy Information Administration (EIA) Indexed Site

S. Underground Natural Gas Storage Developments: 1998-2005 S. Underground Natural Gas Storage Developments: 1998-2005 Energy Information Administration, Office of Oil and Gas, October 2006 1 This special report examines the current status of the underground natural gas storage sector in the United States and how it has changed since 1998, particularly in regards to deliverability from storage, working gas capacity, ownership, and operational capabilities. In addition, it includes a discussion and an analysis of underground natural gas storage expansions in 2005 and an examination of the level of proposed additional storage expansions over the next several years. Questions or comments on the contents of this article should be directed to James Tobin at james.tobin@eia.doe.gov or (202) 586-4835.

496

NNSA Commemorates the 20th Anniversary of the Last Underground Nuclear Test  

National Nuclear Security Administration (NNSA)

the 20th Anniversary of the Last Underground Nuclear Test the 20th Anniversary of the Last Underground Nuclear Test | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > Media Room > Video Gallery > NNSA Commemorates the 20th Anniversary of the ... NNSA Commemorates the 20th Anniversary of the Last Underground Nuclear Test NNSA Commemorates the 20th Anniversary of the Last Underground Nuclear Test

497

Light duty utility arm deployment in Hanford tank T-106  

SciTech Connect

An existing gap in the technology for the remediation of underground waste storage tanks filled by the Light Duty Utility Arm (LDUA) System. On September 27 and 30, 1996, the LDUA System was deployed in underground storage tank T-106 at Hanford. The system performed successfully, satisfying all objectives of the in-tank operational test (hot test); performing close-up video inspection of features of tank dome, risers, and wall; and grasping and repositioning in-tank debris. The successful completion of hot testing at Hanford means that areas of tank structure and waste surface that were previously inaccessible are now within reach of remote tools for inspection, waste analysis, and small-scale retrieval. The LDUA System has become a new addition to the arsenal of technologies being applied to solve tank waste remediation challenges.

Kiebel, G.R.

1997-07-01T23:59:59.000Z

498

Characterizing a lignite formation before and after an underground coal gasification experiment  

E-Print Network (OSTI)

CHARACTERIZING A LIGNITE FORMATION BEFORE AND AFTER AN UNDERGROUND COAL GASIFICATION EXPERIMENT A Thesis by USMAN AHMED Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree... of MASTER OF SCIENCE Nay, 1981 Major Subject: Petrol eum Engineering CHARACTERIZING A LIGNITE FORMATION BEFORE AND AFTER AN UNDERGROUND COAL GASIFICATION EXPERIMENT A Thesis by USMAN AHMED approved as to sty1e and content by: airma o i ee Head f...

Ahmed, Usman

2012-06-07T23:59:59.000Z

499

California Natural Gas in Underground Storage (Base Gas) (Million Cubic  

U.S. Energy Information Administration (EIA) Indexed Site

Base Gas) (Million Cubic Feet) Base Gas) (Million Cubic Feet) California Natural Gas in Underground Storage (Base Gas) (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 243,944 243,944 243,944 243,944 243,944 243,944 243,944 243,944 243,944 243,944 243,944 243,944 1991 243,944 243,944 243,944 243,944 243,944 243,944 243,944 243,944 248,389 248,389 248,389 248,389 1992 248,389 248,389 248,389 248,389 248,389 248,389 248,389 248,389 248,389 248,389 248,389 250,206 1993 250,206 250,206 247,228 246,345 247,699 247,950 247,109 248,215 248,944 251,050 247,420 247,425 1994 251,384 251,384 251,384 251,384 251,384 251,384 251,384 251,384 247,435 247,435 247,435 247,435 1995 247,419 247,419 247,419 247,419 247,419 247,419 247,419 247,419 247,419 247,419 247,419 247,419

500

Montana Natural Gas in Underground Storage (Working Gas) (Million Cubic  

U.S. Energy Information Administration (EIA) Indexed Site

Working Gas) (Million Cubic Feet) Working Gas) (Million Cubic Feet) Montana Natural Gas in Underground Storage (Working Gas) (Million Cubic Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1990 184,212 180,918 178,620 181,242 179,235 181,374 183,442 187,348 185,848 181,029 1991 179,697 178,285 176,975 176,918 178,145 179,386 181,094 182,534 182,653 181,271 178,539 174,986 1992 111,256 109,433 109,017 109,150 110,146 110,859 111,885 112,651 112,225 110,868 107,520 101,919 1993 96,819 92,399 89,640 87,930 86,773 86,048 87,257 87,558 88,012 87,924 85,137 81,930 1994 78,106 72,445 71,282 70,501 71,440 73,247 74,599 75,685 77,456 78,490 76,784 74,111 1995 70,612 68,618 67,929 68,727 70,007 72,146 75,063 78,268 79,364 78,810 75,764 70,513