Sample records for operating ratios energy-management

  1. ENERGY MANAGEMENT OPERATIONAL PROCEDURE MANUAL

    E-Print Network [OSTI]

    Harman, Neal.A.

    ENERGY MANAGEMENT OPERATIONAL PROCEDURE MANUAL Swansea University Estates Services Singleton Park Swansea SA2 8PP Tel 01792 295819 Fax 01792 295820 #12;Swansea University Energy Management Operational ......................................................................................11 #12;Swansea University Energy Management Operational Procedural Manual Estates Services April 2008

  2. Energy Management of Chiller Plant for Improved Efficiency and Operation

    E-Print Network [OSTI]

    Alexander, D. P.; Rice, L. S.

    while meeting the operational requirements of plant chillers. The chiller energy management is an integrated part of total energy management system including the boilers. A uniform display is used for boilers, chillers, compressors, etc. Specific... displayed and organized so that the plant is easily manageable. With the outdated equipment, a major control system failure could generate discomfort. Furthermore, more manual observation and adjustments were required to provide a trouble-free operation...

  3. Using Energy Management Control Systems for HVAC Operational Diagnostics

    E-Print Network [OSTI]

    Stum, K.

    1998-01-01T23:59:59.000Z

    USING ENERGY MANAGEMENT CONTROL SYSTEMS FOR HVAC OPERATIONAL DIAGNOSTICS Karl Stum, P.E. Portland Energy Conservation, Inc. 92 1 SW Washington, Suite 3 12 Portland, OR 97205 503-248-4636 Fax 503-295-0820 ABSTRACT The power and flexibility... Proceedings, June 1997. Meyers, S.; E. Mills; A. Chen; L. Demsetz "Building Data Visualization for Diagnostics," ASHRAE Journal, June 1996. PECl (Portland Energy Conservation, Inc.). Energy Management C0ntrof Systems-A Practical Guiak, 1997. Sparks, R...

  4. Effective Energy Management Through Better Operator Training

    E-Print Network [OSTI]

    Shah, G. C.

    1979-01-01T23:59:59.000Z

    A majority of the energy conservation programs in the chemical process industry aims at gaining cooperation and motivation from the operators or technicians. These programs are useful but they seem to lack an important aspect: "Operator training...

  5. Energy Management in Mobile Devices with the Cinder Operating System

    E-Print Network [OSTI]

    Levis, Philip

    Energy Management in Mobile Devices with the Cinder Operating System Arjun Roy, Stephen M. Rumble and applications to con- trol and manage limited device resources such as energy. Cinder introduces two new hoarding unused energy. Cinder additionally institutes a global half-life to prevent malicious applications

  6. Energy Management in Mobile Devices with the Cinder Operating System

    E-Print Network [OSTI]

    Roy, Arjun

    We argue that controlling energy allocation is an increasingly useful and important feature for operating systems, especially on mobile devices. We present two new low-level abstractions in the Cinder operating system, ...

  7. Energy management in mobile devices with the cinder operating system

    E-Print Network [OSTI]

    Roy, Arjun

    We argue that controlling energy allocation is an increasingly useful and important feature for operating systems, especially on mobile devices. We present two new low-level abstractions in the Cinder operating system, ...

  8. Post-Retrocommissioning HVAC Operations Monitoring Using Enterprise-Wide energy Management System

    E-Print Network [OSTI]

    Amarnani, N.; Roberts, B.; Choy, H.

    2007-01-01T23:59:59.000Z

    components/systems to diagnose and resolve root causes of operational deficiencies. During the implementation phase, new energy efficiency measures were installed, sequence of operations were optimized and functionally tested. System-level benchmark models...

  9. Operation Diagnosis for Buildings Connecting Building Management Systems with Energy Management Systems 

    E-Print Network [OSTI]

    Mehler, G.

    2008-01-01T23:59:59.000Z

    8th International Conference for Enhanced Building Operations - ICEBO?08 Conference Center of the Federal Ministry of Economics and Technology Berlin, October 20 - 22, 2008 Dipl.-Ing. G?nther Mehler Johnson Controls Systems & Service Gmb...

  10. Operation Diagnosis for Buildings Connecting Building Management Systems with Energy Management Systems

    E-Print Network [OSTI]

    Mehler, G.

    2008-01-01T23:59:59.000Z

    Reducing energy consumption of buildings is a good contribution to protect the environment and to reduce costs. The first and most important step to operate a building most efficiently is to make aware of most of the technical parameters. Connecting...

  11. High Compression Ratio Turbo Gasoline Engine Operation Using...

    Broader source: Energy.gov (indexed) [DOE]

    Compression Ratio Turbo Gasoline Engine Operation Using Alcohol Enhancement PI: John B. Heywood Sloan Automotive Laboratory Massachusetts Institute of Technology June 19, 2014...

  12. Behavioral Energy Management: Improving Conservation Behavior and Attitudes with Operant Conditioning

    E-Print Network [OSTI]

    Eibes, T.; Jedlicka, A.

    , institutional and cOlnmercial sectors in the ECM model.' This link is traditionally are reporting "slippage" of the accomplishments referred to as Operant Conditioning and is part and support established early-on in the of a general area of psychology called... of these theories are dlfferent, but careful review reveals that consistently laced throughout these theories are three common and necessary elements. These elements are Meaningfulness, Responsibility, and Feedback. (For a more detailed explanation...

  13. Top Operations and Maintenance (O&M) Efficiency Opportunities at DoD/Army Sites - A Guide for O&M/Energy Managers and Practitioners

    SciTech Connect (OSTI)

    Sullivan, Gregory P.; Dean, Jesse D.; Dixon, Douglas R.

    2007-05-25T23:59:59.000Z

    This report, sponsored the Army's Energy Engineering Analysis Program, provides the Operations and Maintenance (O&M) Energy manager and practitioner with useful information about the top O&M opportunities consistently found across the DoD/Army sector. The target is to help the DoD/Army sector develop a well-structured and organized O&M program.

  14. Facilities Automation and Energy Management

    E-Print Network [OSTI]

    Jen, D. P.

    1983-01-01T23:59:59.000Z

    Computerized facilities automation and energy management systems can be used to maintain high levels of facilities operations efficiencies. The monitoring capabilities provides the current equipment and process status, and the analysis...

  15. Wind Energy Management System EMS Integration Project: Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.; Ma, Jian; Guttromson, Ross T.; Subbarao, Krishnappa; Chakrabarti, Bhujanga B.

    2010-01-01T23:59:59.000Z

    The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind and solar power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation), and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind/solar forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. To improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. Currently, uncertainties associated with wind and load forecasts, as well as uncertainties associated with random generator outages and unexpected disconnection of supply lines, are not taken into account in power grid operation. Thus, operators have little means to weigh the likelihood and magnitude of upcoming events of power imbalance. In this project, funded by the U.S. Department of Energy (DOE), a framework has been developed for incorporating uncertainties associated with wind and load forecast errors, unpredicted ramps, and forced generation disconnections into the energy management system (EMS) as well as generation dispatch and commitment applications. A new approach to evaluate the uncertainty ranges for the required generation performance envelope including balancing capacity, ramping capability, and ramp duration has been proposed. The approach includes three stages: forecast and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence levels. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis, incorporating all sources of uncertainties of both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures) nature. A new method called the “flying brick” technique has been developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation algorithm has been developed to validate the accuracy of the confidence intervals.

  16. Energy Management Working Group: Accelerating Energy Management

    E-Print Network [OSTI]

    Scheihing, P.

    2014-01-01T23:59:59.000Z

    for Standardization (ISO) published the ISO 50001 energy management standard in 2011. ISO 50001 provides industrial companies with guidelines for integrating energy efficiency into their management practices— including fine-tuning production processes... efficiency. GSEP’s Energy Management Working Group (EMWG) advocates the increased adoption of EnMS or ISO 50001 in industry and commercial buildings. It goal is to accelerate the adoption and use of energy management systems in industrial facilities...

  17. Benchmarking Corporate Energy Management

    E-Print Network [OSTI]

    Norland, D. L.

    BENCHMARKING CORPORATE ENERGY MANAGEMENT Dr. Douglas L. Norland Director of Research and Industrial Programs Alliance to Save Energy Washington, DC ABSTRACT There is growing interest among energy managers in finding out how their company...'s energy management procedures and perfonnance compare to that of other companies. Energy management involves everything from setting goals and targets to implementing best maintenance practices. This paper, however, discusses benchmarking energy...

  18. Reduce Building Energy Consumption by Improving the Supply Air Temperature Schedule and Recommissioning the Terminal Boxes, Submitted to the Energy Management and Operations Division at the M.D. Anderson Cancer Center

    E-Print Network [OSTI]

    Liu, M.; Athar, A.; Zhu, Y.; Claridge, D. E.

    1995-01-01T23:59:59.000Z

    At the request of the Energy Management and Operations Department at M.D. Anderson Cancer Center, the Energy Systems Laboratory of Texas A&M University performed a study of optimizing the HVAC operation at its Basic Research Building. The Basic...

  19. Energy Management Working Group: Accelerating Energy Management 

    E-Print Network [OSTI]

    Scheihing, P.

    2014-01-01T23:59:59.000Z

    Countries participating in the Global Superior Energy Performance (GSEP) Energy Management Working Group (EMWG) are leveraging their resources and taking collective action to strengthen national and international efforts to facilitate the adoption...

  20. Office of Inspector General report on audit of Department of Energy management and operating contractor available fees

    SciTech Connect (OSTI)

    NONE

    1996-05-01T23:59:59.000Z

    The Office of Procurement and Assistance Management has proposed changes to the method used to annually calculate and negotiate ``for profit`` management and operating contractor available fees. This proposal will increase contractor fees in exchange for the contractor`s purported assumption of additional risk. In 1991, the Department, through the Accountability Rule, increased contractor fees as an incentive to improve contractor performance and accountability. Despite the lack of measurable benefits of this effort, the Department is crafting a new fee policy which will, depending upon how it is executed, increase fees above the amount provided through the Accountability Rule as an incentive to the Department`s management and operating contractors. The objective of the audit was to determine whether the Department`s proposed change to the fee structure for determining management and operating contractor fees will be cost effective. This report describes the study`s approach, its findings and recommendations, management and auditor comments, and includes appendices with further data.

  1. Sustainable Energy Management Programs

    E-Print Network [OSTI]

    Hanner, S.

    2014-01-01T23:59:59.000Z

    Sustainable Energy Management Programs Steve Hanner Allen ISD/TEMA . ESL-KT-14-11-45 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 Starting an Energy Management Program • Recognize need, Elicit District Commitment... • Appoint Energy Manager • Analyze Existing Conditions • Develop Plan • Implement and Monitor Program ESL-KT-14-11-45 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 Sustainable Programs Feature – District Commitment...

  2. Energy Management Systems

    E-Print Network [OSTI]

    Ferland, K.

    2007-01-01T23:59:59.000Z

    This presentation will address results from a pilot project with 10 chemical plants on energy management systems and the development of an energy efficiency plant certification program....

  3. Wind Energy Management System Integration Project Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.; Ma, Jian; Guttromson, Ross T.; Subbarao, Krishnappa; Chakrabarti, Bhujanga B.

    2010-09-01T23:59:59.000Z

    The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation) and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. In order to improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively, by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. In this report, a new methodology to predict the uncertainty ranges for the required balancing capacity, ramping capability and ramp duration is presented. Uncertainties created by system load forecast errors, wind and solar forecast errors, generation forced outages are taken into account. The uncertainty ranges are evaluated for different confidence levels of having the actual generation requirements within the corresponding limits. The methodology helps to identify system balancing reserve requirement based on a desired system performance levels, identify system “breaking points”, where the generation system becomes unable to follow the generation requirement curve with the user-specified probability level, and determine the time remaining to these potential events. The approach includes three stages: statistical and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence intervals. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis incorporating all sources of uncertainty and parameters of a continuous (wind forecast and load forecast errors) and discrete (forced generator outages and failures to start up) nature. Preliminary simulations using California Independent System Operator (California ISO) real life data have shown the effectiveness of the proposed approach. A tool developed based on the new methodology described in this report will be integrated with the California ISO systems. Contractual work is currently in place to integrate the tool with the AREVA EMS system.

  4. Energy Management Webinar Series

    Broader source: Energy.gov [DOE]

    Boost your knowledge on how to implement an energy management system through this four-part webinar series from the Superior Energy Performance program. Each webinar introduces various elements of the ISO 50001 energy management standard—based on the Plan-Do-Check-Act approach—and the associated steps of DOE's eGuide for ISO 50001 software tool.

  5. Integrating Concurrency Control and Energy Management in Device Drivers

    E-Print Network [OSTI]

    Levis, Philip

    Integrating Concurrency Control and Energy Management in Device Drivers Kevin Klues , Vlado@cs.berkeley.edu dgay@intel-research.net Abstract Energy management is a critical concern in wireless sensornets. De- spite its importance, sensor network operating systems today pro- vide minimal energy management support

  6. Successes in School Energy Management

    E-Print Network [OSTI]

    Brown, J.

    2012-01-01T23:59:59.000Z

    - Master Plan ? Knows where the energy is going ? Benchmarking - Smart Metering ? Refines operations to match current needs ? M&O - RetroCommissioning - Behavioral ? Never stops looking for ways to improve ? Continuous Auditing...CATEE 2012 ?Successes in School Energy Management? Jim Brown, P.E. Principal ? Facilities Division Regional Manager 512-258-0547 jwbrown@terracon.com The Successful Energy Department ---- ? Always has a PLAN ? Energy Policy - Energy Plan...

  7. Energy Management Programs- Monitoring Performance

    E-Print Network [OSTI]

    Pauls, S. P.; Shamy, M. D.

    ENERGY MANAGEMENT PROGRAMS - MONITORING PERFORMANCE Stanley P. Pauls Mustafa D. Shamy Merck & Co., Inc. Rahway, N. J. ABSTRACT of the historical energy consumption records. Energy use standards have been established to Steam Model monitor... energy conservation performance in bulk pharmaceutical plants. The model considers The basic steam model for most industrial process, comfort heating, and fixed loads. operations is made up of the following components: As the oil crisis developed...

  8. Corporate Energy Management Process

    E-Print Network [OSTI]

    Geiger, T.

    2013-01-01T23:59:59.000Z

    . May 21-24, 2013 Corporate Energy Management Process 2 ?Brief introduction to BASF ? BASF Corporate Energy Management ? Management Support ? Goals ? Continuous Improvement ? Best Practices ? Recognition ?Summary ESL-IE-13-05-25 Proceedings...-value products ? Intelligent, sustainable system solutions ? 2012 Sales: ?72.1 Billion ? Employees: 110,000 Company overview BASF ? The Chemical Company ESL-IE-13-05-25 Proceedings of the Thrity-Fifth Industrial Energy Technology Conference New Orleans, LA...

  9. Harrison Radiator Division's Energy Management, Reporting and Accounting System

    E-Print Network [OSTI]

    Goubeaux, R. J.

    HARRISON RADIATOR DIVISION'S ENERGY MANAGEMENT, REPORTING and ACCOUNTING SYSTEM Ronald J. Goubeaux Harrison Radiator Division Lockport, New York ABSTRACT Energy management is essential for obtaining the lowest possible product..., farm equipment, small aircraft and other types of vehicles. The energy management, reporting and accounting system that is covered in this paper is operating in Harrison's West Complex of the New York Operations located in Lockport, Western...

  10. Strategies for Successful Energy Management

    Broader source: Energy.gov [DOE]

    This presentation, given through the DOE's Technical Assitance Program (TAP), provides information on energy management for the portfolio manager initiative

  11. Energy Management and Conservation Plan

    E-Print Network [OSTI]

    Energy Management and Conservation Plan December 2005 #12;Texas Transportation Institute December 2005 Energy Management and Conservation Plan Page 2 of 24 Table of Contents Section One: Executive: Reporting Progress #12;Texas Transportation Institute December 2005 Energy Management and Conservation Plan

  12. Energy Management Issued: June 2010

    E-Print Network [OSTI]

    Energy Management Policy Issued: June 2010 Revised: Responsible Administrative Unit: Finance.0 BACKGROUND AND PURPOSE The Engineering and Energy Management division of the Department of Facilities Management at the Colorado School of Mines ("Mines" or "the school") has developed an Energy Management

  13. Energy Management Curriculum Starter Kit

    SciTech Connect (OSTI)

    Turner, W.C.

    1987-02-01T23:59:59.000Z

    The Energy Management Curriculum Starter Kit was designed to help engineering educators develop and teach energy management courses. Montana State University and Oklahoma State University courses are embodied in the model curriculum given. The curricula offered at many other universities throughout the United States are also presented. The kit was designed specifically to train engineering students to be good energy managers. Courses at both the undergraduate and postgraduate level are presented.

  14. Energy manager design for microgrids

    SciTech Connect (OSTI)

    Firestone, Ryan; Marnay, Chris

    2005-01-01T23:59:59.000Z

    On-site energy production, known as distributed energy resources (DER), offers consumers many benefits, such as bill savings and predictability, improved system efficiency, improved reliability, control over power quality, and in many cases, greener electricity. Additionally, DER systems can benefit electric utilities by reducing congestion on the grid, reducing the need for new generation and transmission capacity, and offering ancillary services such as voltage support and emergency demand response. Local aggregations of distributed energy resources (DER) that may include active control of on-site end-use energy devices can be called microgrids. Microgrids require control to ensure safe operation and to make dispatch decisions that achieve system objectives such as cost minimization, reliability, efficiency and emissions requirements, while abiding by system constraints and regulatory rules. This control is performed by an energy manager (EM). Preferably, an EM will achieve operation reasonably close to the attainable optimum, it will do this by means robust to deviations from expected conditions, and it will not itself incur insupportable capital or operation and maintenance costs. Also, microgrids can include supervision over end-uses, such as curtailing or rescheduling certain loads. By viewing a unified microgrid as a system of supply and demand, rather than simply a system of on-site generation devices, the benefits of integrated supply and demand control can be exploited, such as economic savings and improved system energy efficiency.

  15. Equivalence Ratio-EGR Control of HCCI Engine Operation and the Potential for Transition to Spark-Ignited Operation

    SciTech Connect (OSTI)

    Martinez-Frias, J; Aceves, S M; Flowers, D L; Smith, J R; Dibble, R

    2001-07-31T23:59:59.000Z

    This research investigates a control system for HCCI engines, where equivalence ratio, fraction of EGR and intake pressure are adjusted as needed to obtain satisfactory combustion. HCCI engine operation is analyzed with a detailed chemical kinetics code, HCT (Hydrodynamics, Chemistry and Transport), that has been extensively modified for application to engines. HCT is linked to an optimizer that determines the operating conditions that result in maximum brake thermal efficiency, while meeting the peak cylinder pressure restriction. The results show the values of the operating conditions that yield optimum efficiency as a function of torque and rpm. The engine has high NO{sub x} emissions for high power operation, so the possibility of switching to stoichiometric operation for high torque conditions is considered. Stoichiometric operation would allow the use of a three-way catalyst to reduce NO{sub x} emissions to acceptable levels. Finally, the paper discusses the possibility of transitioning from HCCI operation to SI operation to achieve high power output.

  16. Demand Control Utilizing Energy Management Systems - Report of Field Tests

    E-Print Network [OSTI]

    Russell, B. D.; Heller, R. P.; Perry, L. W.

    1984-01-01T23:59:59.000Z

    Energy Management systems and particularly demand controllers are becoming more popular as commercial and light industrial operations attempt to reduce their electrical usage and demand. Numerous techniques are used to control energy use and demand...

  17. Process and Energy Optimization Revitalizes Energy Management at Eastman

    E-Print Network [OSTI]

    Greenwaldt, W. C.

    2007-01-01T23:59:59.000Z

    In 2005, the Eastman-Texas Operations Energy Management Team (EMT), in response to rapidly increasing energy prices, initiated a new energy optimization program to optimize the site’s energy intensity. This new program utilized a process and energy...

  18. Energy Management Report November 2014

    E-Print Network [OSTI]

    Energy Management Report November 2014 #12; TAMU Energy Management Report it established for reducing its usage of electricity, gasoline, and natural gas: Energy consumption per period from FY02 ­ FY14. The goal in the 2005 Energy Conservation Plan was to achieve an EUI of 275

  19. Industrial Energy Management: Doing More with Less 

    E-Print Network [OSTI]

    Sheppard, J.; Tisot, A.

    2006-01-01T23:59:59.000Z

    INDUSTRIAL ENERGY MANAGEMENT: DOING MORE WITH LESS Jason Sheppard, Industrial Market Segment Manager Anthony Tisot, Communications Manager Power Monitoring and Control SCHNEIDER ELECTRIC Victoria, BC, Canada ABSTRACT The cost of doing... and quality of electricity can significantly affect operations and profits, it has traditionally been accepted as a non-negotiable business expense — the utility bill is paid each month without question, and the cost goes unchallenged. But energy is not a...

  20. Linking Continuous Energy Management and Open Automated Demand Response

    E-Print Network [OSTI]

    Piette, Mary Ann

    2009-01-01T23:59:59.000Z

    Linking Continuous Energy Management and Open AutomatedKeywords: Continuous Energy Management, Automated Demandlinking continuous energy management and continuous

  1. Energy Management at SMARTboard

    E-Print Network [OSTI]

    Jagen, P. R.

    2008-01-01T23:59:59.000Z

    of operations. Whenever a metric is underperforming, links appear that take the user to other displays, such as corrective action, operating procedures, and diagnostic tools. Summary data from area-based SMARTboards can be linked into a site display for plant...

  2. Federal Energy Management Program (FEMP) Technical Assistance...

    Energy Savers [EERE]

    Federal Energy Management Program (FEMP) Technical Assistance Request Portal User Guide Federal Energy Management Program (FEMP) Technical Assistance Request Portal User Guide...

  3. Interagency Energy Management Task Force Members

    Broader source: Energy.gov [DOE]

    The Interagency Energy Management Task Force is led by the Federal Energy Management Program director. Members include energy and sustainability managers from federal agencies.

  4. Implementing a Corporate Energy Management System

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Implementing a Corporate Energy Management System" Steve Schultz Corporate Energy Manager 3M Presented at the U.S. Department of Energy Industrial Technologies Program June 3, 2010...

  5. Energy manager design for microgrids

    E-Print Network [OSTI]

    Firestone, Ryan; Marnay, Chris

    2005-01-01T23:59:59.000Z

    signals to a building energy management system already inStadler. 2003 “Distributed Energy Resources in Practice: Aof µGrid Distributed Energy Resource Potential Using DER-CAM

  6. Communications and the Energy Manager

    E-Print Network [OSTI]

    Cooper, J. I.

    developed to aid in the communications needs of such diverse groups. Each group has specific informational requirements that must be fulfilled for the Energy Management Program to be successful. This paper presents some of the methods that the author has...

  7. EWEB- Energy Management Services Loan

    Broader source: Energy.gov [DOE]

    The Eugene Water & Electric Board (EWEB) offers cash incentives and low interest loans to businesses as part of the Energy Management Services program for the installation of solar domestic,...

  8. EWEB- Energy Management Services Rebate

    Broader source: Energy.gov [DOE]

    The Eugene Water & Electric Board (EWEB) offers cash incentives and low interest loans to businesses as part of the Energy Management Services program for the installation of solar domestic,...

  9. Deere & Company Energy Management Program 

    E-Print Network [OSTI]

    Darby, D. F.

    1981-01-01T23:59:59.000Z

    An overview of the Deere & Company Energy Management Program is discussed. A review is made of seven key elements which have contributed to the success of the program. Installed projects and established programs are identified and discussed...

  10. Global Energy Management System

    E-Print Network [OSTI]

    Eidt, B. D.

    2005-01-01T23:59:59.000Z

    Exxon Mobil Corporation has undertaken voluntary actions to continuously improve energy efficiency in our operations for many years. From 1973 to 1999, we improved the energy efficiency of our refineries and chemical plants by over 35 percent...

  11. Noise Sensitivity of Teager-Kaiser Energy Operators and Their Ratios

    E-Print Network [OSTI]

    Banerjee, Pradeep Kr

    2015-01-01T23:59:59.000Z

    The Teager-Kaiser energy operator (TKO) belongs to a class of autocorrelators and their linear combination that can track the instantaneous energy of a nonstationary sinusoidal signal source. TKO-based monocomponent AM-FM demodulation algorithms work under the basic assumption that the operator outputs are always positive. In the absence of noise, this is assured for pure sinusoidal inputs and the instantaneous property is also guaranteed. Noise invalidates both of these, particularly under small signal conditions. Post-detection filtering and thresholding are of use to reestablish these at the cost of some time to acquire. Key questions are: (a) how many samples must one use and (b) how much noise power at the detector input can one tolerate. Results of study of the role of delay and the limits imposed by additive Gaussian noise are presented along with the computation of the cumulants and probability density functions of the individual quadratic forms and their ratios.

  12. Energy Management in Wireless Sensor Network Operations 

    E-Print Network [OSTI]

    Mohapatra, Arupa Kumar

    2013-07-26T23:59:59.000Z

    problem (Case I), we consider minimizing energy and node replacement costs in underwater wireless sensor networks for seismic monitoring application. In this case, we introduce mixed-integer programming (MIP) formulations based on a combined routing...

  13. Oklahoma Industrial Energy Management Program

    E-Print Network [OSTI]

    Turner, W. C.; Webb, R. E.; Phillips, J. M.; Viljoen, T. A.

    1979-01-01T23:59:59.000Z

    The need for sound energy management is no longer worthy of debate. Action is necessary and much is being done by U.S. industry. Unfortunately, however, the majority of the work is being done by the few large energy intensive industries throughout...

  14. Oklahoma Industrial Energy Management Program

    E-Print Network [OSTI]

    Turner, W. C.; Estes, C. B.

    1982-01-01T23:59:59.000Z

    In Oklahoma, industry consumes about 35% of the total energy consumed. While it is true that much work has been done in the larger companies, most small to medium sized companies have yet to undertake a substantial energy management program. Often...

  15. Energy Management at Deere & Company 

    E-Print Network [OSTI]

    Boyd, M. P.

    1979-01-01T23:59:59.000Z

    Deere & Company appreciates the opportunity to discuss energy management and conservation with you. Energy is a topic that will occupy our thoughts for many years to come and certainly will be in the forefront in the near future. It is a subject...

  16. Microstructural Design for Stress Wave Energy Management /

    E-Print Network [OSTI]

    Tehranian, Aref

    2013-01-01T23:59:59.000Z

    Nemat-Nasser, Stress-wave energy management through materialNasser, S. , 2010. Stress-wave energy management throughconstitute pressure wave energy and/or shear wave energy.

  17. Establishing and Maintaining Effective Energy Management Practices

    E-Print Network [OSTI]

    Giffin, T. M.

    2008-01-01T23:59:59.000Z

    SAIC has developed, and has delivered over the past 4 years, training and tools to industry for them to implement energy management practices. Practical Energy Management (PEM) has been delivered to over 1000 industry professionals, arming them...

  18. Programs of the Governor's Energy Management Center

    E-Print Network [OSTI]

    Verdict, M.

    1988-01-01T23:59:59.000Z

    The 70th Texas Legislature transferred the Energy Efficiency Division of the Public Utility Commission to the Governor's Office in September 1987 and directed the Governor's Energy Management Center (GEMC) to perform energy management services...

  19. EPRI's Industrial Energy Management Program

    E-Print Network [OSTI]

    Mergens, E.; Niday, L.

    EPRI's INDUSTRIAL ENERGY MANAGEMENT PROGRAM ED MERGENS MANAGER EPRI's CHEMICALS & PETROLEUM OFFICE HOUSTON, TEXAS ABSTRACT The loss of American industry jobs to foreign competition is made worse by national concerns over fuels combustion... are funded at a level in excess of SlO million annually. By providing technical guidance and sponsoring research and development projects, these Centers and Offices are a key element in EPRI's role of improving the value of electricity to consumers...

  20. BASF Corporate Energy Management Process

    E-Print Network [OSTI]

    Geiger, T.

    2014-01-01T23:59:59.000Z

    Process 2 2 ? Brief introduction to BASF ? BASF Corporate Energy Management ? Management Support ? Goals ? Continuous Improvement ? Knowledge Sharing ? Recognition ESL-IE-14-05-30 Proceedings of the Thrity-Sixth Industrial Energy Technology Conference... • 2013 Sales: €74 Billion • Employees: 112,000 Company overview BASF – The Chemical Company 3 ESL-IE-14-05-30 Proceedings of the Thrity-Sixth Industrial Energy Technology Conference New Orleans, LA. May 20-23, 2014 Structure of BASF’s segments...

  1. Office of Legacy Management FY 2009 Energy Management Data Report...

    Office of Environmental Management (EM)

    Office of Legacy Management FY 2009 Energy Management Data Report Office of Legacy Management FY 2009 Energy Management Data Report FY 2009 Energy Management Performance Summary...

  2. Effects of operating conditions, compression ratio, and gasoline reformate on SI engine knock limits

    E-Print Network [OSTI]

    Gerty, Michael D

    2005-01-01T23:59:59.000Z

    A set of experiments was performed to investigate the effects of air-fuel ratio, inlet boost pressure, hydrogen rich fuel reformate, and compression ratio on engine knock behavior. For each condition the effect of spark ...

  3. Trends in Energy Management Technology - Part 3: State of Practice of Energy Management, Control, and Information Systems

    E-Print Network [OSTI]

    Yee, Gaymond; Webster, Tom

    2004-01-01T23:59:59.000Z

    November 2000. Trends in Energy Management TechnologyTrends in Energy Management Technology FEMP/NTDP TechnicalT. L. , "Trends in Energy Management Technology - Enabling

  4. Performance Directed Energy Management for Main Memory and Disks #

    E-Print Network [OSTI]

    Zhou, Yuanyuan

    in the design of computing systems. For battery­operated mobile devices, energy consumption directly affects]. The storage hierarchy, which includes memory and disks, is a major energy consumer in computer systemsPerformance Directed Energy Management for Main Memory and Disks # Xiaodong Li, Zhenmin Li, Francis

  5. The Role of Analog Instrumentation in Energy Management

    E-Print Network [OSTI]

    Moore, J. A.

    1979-01-01T23:59:59.000Z

    that will pay back material and installation costs in an acceptable period of time. The owner or operator becomes the decision making portion of the system in this case. Three categories of Energy Management are identified in analog instrumentation: Auditing... are "find out what has to be done, do it, then check to see that it is performing as it was intended to." AUDIT Auditing is the first step. What does auditing mean in the context of Energy Management? If we define a system as an area in which activities...

  6. Blazing the energy trail: The Municipal Energy Management Program

    SciTech Connect (OSTI)

    Not Available

    1994-12-01T23:59:59.000Z

    The Urban Consortium Energy Task Force pioneers energy and environmental solutions for US cities and counties. When local officials participate in the task force, they open the door to many resources for their communities. The US is entering a period of renewed interest in energy management. Improvements in municipal energy management allow communities to free up energy operating funds to meet other needs. These improvements can even keep energy dollars in the community through the purchase of services and products used to save energy. With this idea in mind, the US Department of Energy Municipal Energy Management Program has funded more than 250 projects that demonstrate innovative energy technologies and management tools in cities and counties through the Urban Consortium Energy Task Force (UCETF). UCETF helps the US Department of Energy foster municipal energy management through networks with cities and urbanized counties and through links with three national associations of local governments. UCETF provides funding for projects that demonstrate innovative and realistic technologies, strategies, and methods that help urban America become more energy efficient and environmentally responsible. The task force provides technical support to local jurisdictions selected for projects. UCETF also shares information about successful energy management projects with cities and counties throughout the country via technical reports and project papers. The descriptions included here capsulize a sample of UCETF`s demonstration projects around the country.

  7. Predictive energy management for hybrid electric vehicles -Prediction horizon and

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Predictive energy management for hybrid electric vehicles - Prediction horizon and battery capacity of a combined hybrid electric vehicle. Keywords: Hybrid vehicles, Energy Management, Predictive control, Optimal predictive energy management realistic. This energy management strategy uses a dynamic programming algorithm

  8. Linac Energy Management for LCLS

    SciTech Connect (OSTI)

    Chu, Chungming; /SLAC; Iverson, Richard; /SLAC; Krejcik, Patrick; /SLAC; Rogind, Deborah; /SLAC; White, Greg; /SLAC; Woodley, Mark; /SLAC

    2012-07-05T23:59:59.000Z

    Linac Energy Management (LEM) is a control system program that scales magnet field set-point settings following a change in beam energy. LEM is necessary because changes in the number, phase, and amplitude of the active klystrons change the beam's rigidity, and therefore, to maintain constant optics, one has to change focusing gradients and bend fields accordingly. This paper describes the basic process, the control system application programs we developed for LEM, and some of the implementation lessons learned at the Linac Coherent Light Source (LCLS).

  9. Federal Energy Management Success Stories

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers New Training on Energy6 Federal Energy Management Success Stories en FEMP and

  10. Lead by Example with Smart Energy Management

    SciTech Connect (OSTI)

    Not Available

    2006-07-01T23:59:59.000Z

    The Lead by Example with Smart Energy Management brochure describes FEMP's services, namely financing and acquisition support, technical assistance and policy, and outreach and coordination.

  11. PHEV Engine Control and Energy Management Strategy

    Broader source: Energy.gov (indexed) [DOE]

    Oak Ridge National Laboratory PHEV Engine Control and Energy Management Strategy This presentation does not contain any proprietary, confidential, or otherwise restricted...

  12. Predictive Technology Development and Crash Energy Management...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2009 -- Washington D.C. lm09kia.pdf More Documents & Publications ACC100 Crash Energy Management Advanced Materials and Processing of Composites for High Volume Applications...

  13. Energy management handbook. Second edition

    SciTech Connect (OSTI)

    Turner, W.C.

    1993-01-01T23:59:59.000Z

    Separate abstracts were prepared for 25 chapters of this book. Written by a team of professionals in response to steadily accelerating energy costs, this fact-packed guide is designed as a practical, stand alone reference for those responsible for managing energy costs. The second edition has been completely updated, and is published in an expanded format for easier reference. In it is all the data and information needed to design and implement a successful energy management program for businesses, commercial buildings and industrial plants. By applying the simple principles and techniques contained in the handbook, it is possible to realize a cost savings of 15-30% and some companies have achieved as much as 60% savings.

  14. The Part-time MBA Energy Management Our MBA Energy Management Mission

    E-Print Network [OSTI]

    Levi, Ran

    The Part-time MBA Energy Management Our MBA Energy Management Mission To deliver high quality, energy industry focussed, graduate management education that prepares individuals for their future Management for? The part-time MBA Energy Management programme at the Graduate Business School is designed

  15. Analysis of Energy Management System Control Philosophies Utilizing Collected Field Data

    E-Print Network [OSTI]

    Russell, B. D.; Gerloff, G. W.; Heller; R. P.; Perry, L. W.

    1983-01-01T23:59:59.000Z

    Small commercial and light industrial operations are turning to low-cost energy management controllers in efforts to reduce their electrical usage and demand. These controllers offer a variety of techniques to obtain this goal. To study the effects...

  16. PV Integration by Building Energy Management System

    E-Print Network [OSTI]

    Boyer, Edmond

    stands for any variable that could be PV, grid power, or load power if calculation is valid for allPV Integration by Building Energy Management System Rim.Missaoui¹, Ghaith.Warkozek¹, Seddik. BachaLab.grenoble-inp.fr Abstract- This paper focuses on Energy Management System (EMS) applied to the residential sector. The EMS

  17. Synthesised Constraint Models for Distributed Energy Management

    E-Print Network [OSTI]

    Reif, Wolfgang

    generation [1], demand-side manage- ment, or building control software. In a producer-based view, supplySynthesised Constraint Models for Distributed Energy Management Alexander Schiendorfer, Jan frequently encountered in energy management systems such as the coordination of power generators in a virtual

  18. Avoidance behavior in a fixed-ratio three free-operant avoidance situation

    E-Print Network [OSTI]

    King, Thomas Michael

    1971-01-01T23:59:59.000Z

    discrimination. The results did not lend support to the Conditioned Aversive Temporal Stimuli theory of reinforcement in free-operant avoidance proposed by Anger (1963). The notion that a response-contingent stimulus, in a free-operant avoidance situation... 37 38 40 42 CHAPTER I INTRODUCTION In discriminative avoidance procedures, a warning signal increases the probability of a response which allows the sub]ect to avoid a noxious stimulus (Kimble, 1961). Reinforcement of this avoidance behavior...

  19. Predictive energy Optimization: The Next Generation of Energy Management 

    E-Print Network [OSTI]

    Dickinson, P.

    2013-01-01T23:59:59.000Z

    energy management systems. A quantum leap in building intelligence is required to close the gap between the current state of building operations and the needs of smart grids and smart cities. Unfortunately for the building HVAC controls industry... information and other information and make informed decisions. These informed decisions present the quantum leap required to bridge the gap between buildings run on rules of thumb to the smart buildings required by smart grids and smart cities. Figure...

  20. Predictive energy Optimization: The Next Generation of Energy Management

    E-Print Network [OSTI]

    Dickinson, P.

    2013-01-01T23:59:59.000Z

    energy management systems. A quantum leap in building intelligence is required to close the gap between the current state of building operations and the needs of smart grids and smart cities. Unfortunately for the building HVAC controls industry... information and other information and make informed decisions. These informed decisions present the quantum leap required to bridge the gap between buildings run on rules of thumb to the smart buildings required by smart grids and smart cities. Figure...

  1. Energy Management and Control System: Desired Capabilities and Functionality

    SciTech Connect (OSTI)

    Hatley, Darrel D.; Meador, Richard J.; Katipamula, Srinivas; Brambley, Michael R.; Wouden, Carl

    2005-04-29T23:59:59.000Z

    This document discusses functions and capabilities of a typical building/facility energy management and control systems (EMCS). The overall intent is to provide a building operator, manager or engineer with basic background information and recommended functions, capabilities, and good/best practices that will enable the control systems to be fully utilized/optimized, resulting in improved building occupant quality of life and more reliable, energy efficient facilities.

  2. Strategic Energy Management Plan for the 1990's 

    E-Print Network [OSTI]

    Fiorino, D. P.; Priest, J. W.

    1987-01-01T23:59:59.000Z

    This paper describes the strategic energy management plan implemented by the Defense Systems and Electronics Group (DSEG) of Texas Instruments (TI) to enable it to meet its energy management challenge into the 1990's. The strategic energy management...

  3. Strategic Energy Management Plan for the 1990's

    E-Print Network [OSTI]

    Fiorino, D. P.; Priest, J. W.

    1987-01-01T23:59:59.000Z

    This paper describes the strategic energy management plan implemented by the Defense Systems and Electronics Group (DSEG) of Texas Instruments (TI) to enable it to meet its energy management challenge into the 1990's. The strategic energy management...

  4. FEMP (Federal Energy Management Program) Update, Spring 1989

    SciTech Connect (OSTI)

    Not Available

    1989-04-01T23:59:59.000Z

    The FEMP Update, published quarterly by the Federal Energy Management Program (FEMP), provides information that will assist federal managers in their energy management responsibilities. The Update is distributed primarily to federal facility and energy management personnel.

  5. System design and dynamic signature identification for intelligent energy management in residential buildings.

    E-Print Network [OSTI]

    Jang, Jaehwi

    2008-01-01T23:59:59.000Z

    for Intelligent Energy Management in Residential Buildingsfor Intelligent Energy Management in Residential Buildingsthat can provide autonomous energy management to residential

  6. The Second US-China Energy Efficiency Forum: Energy Management...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    The Second US-China Energy Efficiency Forum: Energy Management Standards and Implementation The Second US-China Energy Efficiency Forum: Energy Management Standards and...

  7. Better Buildings Workforce Guidelines for Facility Energy Manager...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Guidelines for Facility Energy Manager - 2014 BTO Peer Review Better Buildings Workforce Guidelines for Facility Energy Manager - 2014 BTO Peer Review Presenter: Phil Coleman,...

  8. Automated Home Energy Management (AHEM) Standing Technical Committee...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Home Energy Management (AHEM) Standing Technical Committee Strategic Plan - February 2012 Automated Home Energy Management (AHEM) Standing Technical Committee Strategic Plan -...

  9. Introducing Energy Management Systems into Smaller Facilities

    E-Print Network [OSTI]

    Lawrence, J. A.

    1983-01-01T23:59:59.000Z

    INTRODUCING ENERGY MANAGEMENT SYSTEMS INTO SMALLER FACILITIES John A. Lawrence Tenneco Inc. Houston, Texas ABSTRACT Many small and medium sized commercial buildings are energy hogs. Typically they were designed and built to meet low first...

  10. Model and control for cooperative energy management

    E-Print Network [OSTI]

    Ranade, Vinayak V

    2010-01-01T23:59:59.000Z

    Proto/Amorphous Cooperative Energy Management (PACEM) aims to build and deploy a highly scalable system for smart power grids that will enable efficient demand shaping for small-user networks. Two key problems are to provide ...

  11. Total Energy Management in General Motors

    E-Print Network [OSTI]

    DeKoker, N.

    1979-01-01T23:59:59.000Z

    This paper presents an overview of General Motors' energy management program with special emphasis on energy conservation. Included is a description of the total program organization, plant guidelines, communication and motivation techniques...

  12. Deere and Company Energy Management Program

    E-Print Network [OSTI]

    Boyd, P. M.

    1980-01-01T23:59:59.000Z

    An overview of the Deere & Company energy management program is discussed. A review is made of seven key elements which have contributed to the success of the program. Installed projects and established programs are identified and discussed...

  13. Strategies for Enterprise-Wide Energy Management 

    E-Print Network [OSTI]

    Victor, A.

    2005-01-01T23:59:59.000Z

    Energy management is becoming more and more critical for the process industries, as rising energy prices and increasing emissions constraints continue to be the norm. This paper provides an assessment of the current energy situation in the process...

  14. Energy Management: Back to the Basics

    E-Print Network [OSTI]

    Diamond, S.

    2007-01-01T23:59:59.000Z

    energy management system with “top-down” support • Conversion of 2 boilers to a CO control strategy • Using combustion analysis metrics to drive boiler pre-heater cleanings • Deaerator optimization • Utility leak repair program • Steam trap management...

  15. General Purpose Microcomputers in Energy Management

    E-Print Network [OSTI]

    Schmidt, P. S.

    1981-01-01T23:59:59.000Z

    these may be implemented in energy management. A project at the University of Texas at Austin to develop a package of energy conservation software is described, and examples are given of other commercially available software suitable for energy conservation...

  16. Energy Management Standards (EnMS)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Management Standards (EnMS) Paul Scheihing U.S. DOE January, 2009 2 Why an Energy Management Standard? Most energy efficiency in industry is achieved through changes in how energy...

  17. Functional Facilities Management Energy Management Structure

    E-Print Network [OSTI]

    Gulliver, Robert

    Functional Facilities Management Energy Management Structure Jerome Malmquist Director Erick Van Controls Systems Jeff Davis Assistant Director, Facilities Engineering & Energy Efficiency Gene Husted Principal Engineer / Commissioning Emily Robin-Abbott St. Paul Energy Engineer & Technicians Supervisor Dan

  18. Rule-Based Energy Management System

    E-Print Network [OSTI]

    Thomasson, F. Y.; Childress, R. L.

    Real time pricing of electricity and rising fossil fuel costs are causing renewed interest in energy management systems (EMS). This paper describes a rule-based EMS which has been implemented at several large industrial powerhouses. It is a PC...

  19. Deere and Company Energy Management Program 

    E-Print Network [OSTI]

    Boyd, P. M.

    1980-01-01T23:59:59.000Z

    An overview of the Deere & Company energy management program is discussed. A review is made of seven key elements which have contributed to the success of the program. Installed projects and established programs are identified and discussed...

  20. Successes in School Energy Management - Energy Monitoring

    E-Print Network [OSTI]

    Corbitt, C.

    2012-01-01T23:59:59.000Z

    Successes in School Energy Management ? Energy Monitoring Chad Corbitt, CEM, ATEM Energy Manager, Klein ISD jcorbitt1@kleinisd.net Wednesday, October 10, 2012 Keys to Energy Monitoring ? Develop an Energy Monitoring plan ? Define... the why, what, how and who of the plan ? Implement the Energy Monitoring plan ? Personnel, data system, reporting ? One Experience in Energy Monitoring Developing an Energy Monitoring Plan ? Why do we need to monitor energy? ? What information...

  1. Real-Time Demand Side Energy Management

    E-Print Network [OSTI]

    Victor, A.; Brodkorb, M.

    2006-01-01T23:59:59.000Z

    Real-Time Demand Side Energy Management Annelize Victor Michael Brodkorb Sr. Business Consultant Business Development Manager Aspen Technology, Inc. Aspen Technology España, S.A. Houston, TX Barcelona, Spain ABSTRACT To remain... competitive, manufacturers must capture opportunities to increase bottom-line profitability. The goal of this paper is to present a new methodology for reducing energy costs – “Demand-Side Energy Management.” Learn how process manufacturers assess energy...

  2. Trends in Energy Management Technology - Part 4: Review of Advanced Applications in Energy Management, Control, and Information Systems

    E-Print Network [OSTI]

    Yee, Gaymond; Webster, Tom

    2003-01-01T23:59:59.000Z

    L. , “State of Practice of Energy Management, Control, andResearch to Practice , Pacific Energy Center, San Francisco,pdf Trends in Energy Management Technology

  3. Trends in Energy Management Technology - Part 4: Review of Advanced Applications in Energy Management, Control, and Information Systems

    E-Print Network [OSTI]

    Yee, Gaymond; Webster, Tom

    2003-01-01T23:59:59.000Z

    ExcelSyus - Excel Energy Technologies, Ltd. http://pdf Trends in Energy Management TechnologyTrends in Energy Management Technology Fault Detection and

  4. The Energy Manager - Should He Be Working Himself Out Of A Job?

    E-Print Network [OSTI]

    Hogeland, A. W.

    1983-01-01T23:59:59.000Z

    and pumping systems, as compared to operating costs including energy costs. This was certainly true of chemi cal, mechanical, electrical, and civil engineers, as well as more specialized types, as they came along. ENERG Y COSTS During that period and up... for the Energy Manager. SUMWlRY I hope that during this discussion we have: 1. Provoked your thinking. 2. Highlighted the need for greater awareness and understanding of energ y parameters by all managers, not just the Energy Manager. 3. Emphasized...

  5. Lifecycle Energy Management in the Tohoku Electric Power headquarters building-APCBC

    E-Print Network [OSTI]

    Yuzawa, H.

    2014-01-01T23:59:59.000Z

    Lifecycle Energy Management in the Tohoku Electric Power Company Head Office Building Hideki Yuzawa (NIKKEN SEKKEI Research Institute) Takeshi Kondo (NIKKEN SEKKEI Research Institute) Shinji Okuda (Tohoku Electric Power) APCBC presentation...th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 ICEBO2014 NSRI Hideki Yuzawa ?2014 yuzawa@nikken.jp Passion for sustainable cities 4 What is “Lifecycle energy management” ? 4 #1 Defined the energy...

  6. Smart Energy Management of Multiple Full Cell Powered Applications

    SciTech Connect (OSTI)

    MOhammad S. Alam

    2007-04-23T23:59:59.000Z

    In this research project the University of South Alabama research team has been investigating smart energy management and control of multiple fuel cell power sources when subjected to varying demands of electrical and thermal loads together with demands of hydrogen production. This research has focused on finding the optimal schedule of the multiple fuel cell power plants in terms of electric, thermal and hydrogen energy. The optimal schedule is expected to yield the lowest operating cost. Our team is also investigating the possibility of generating hydrogen using photoelectrochemical (PEC) solar cells through finding materials for efficient light harvesting photoanodes. The goal is to develop an efficient and cost effective PEC solar cell system for direct electrolysis of water. In addition, models for hydrogen production, purification, and storage will be developed. The results obtained and the data collected will be then used to develop a smart energy management algorithm whose function is to maximize energy conservation within a managed set of appliances, thereby lowering O/M costs of the Fuel Cell power plant (FCPP), and allowing more hydrogen generation opportunities. The Smart Energy Management and Control (SEMaC) software, developed earlier, controls electrical loads in an individual home to achieve load management objectives such that the total power consumption of a typical residential home remains below the available power generated from a fuel cell. In this project, the research team will leverage the SEMaC algorithm developed earlier to create a neighborhood level control system.

  7. Seamless Energy Management Systems Part I: Assessment of Energy

    E-Print Network [OSTI]

    Seamless Energy Management Systems Part I: Assessment of Energy Management Systems and Key to Engineer the Future Electric Energy System #12;#12;Seamless Energy Management Systems Part I: Assessment of Energy Management Systems and Key Technological Requirements Final Project Report Project Faculty Team

  8. Operations and Maintenance Program Structure

    Broader source: Energy.gov [DOE]

    The Federal Energy Management Program recommends Federal operations and maintenance (O&M) programs comprise of five distinct functions: operations, maintenance, engineering, training, and...

  9. Performance Auditing of Energy Management Programs 

    E-Print Network [OSTI]

    White, J. A.

    1988-01-01T23:59:59.000Z

    With the oil crisis of the 1970's, energy management programs became important to both the private and public sectors. But with the decrease of oil prices in the mid 1980's, interest in energy conservation programs has declined. Nevertheless, energy...

  10. IN THIS ISSUE... Energy Management Welcomes Two

    E-Print Network [OSTI]

    Webb, Peter

    July 2003 IN THIS ISSUE... Energy Management Welcomes Two Sign Shop Employees Embark on Adventure U of M Solar Car Team Takes Second July Safety Team HR Assignments Brief Moves to E-mail Format Only reorganization, the Business and Application Support Unit has been reduced to four staff members. Grant Clavelle

  11. Demonstration project in Energy Management programs

    SciTech Connect (OSTI)

    Not Available

    1989-10-01T23:59:59.000Z

    This part of the final report is provided to summarize with more definitive data, the savings realized by the implementation of the Energy Conservation Opportunities (ECOs) identified in the Energy Management Plan (EMP), and for those measures implemented by the Energy Service Company (ESCO).

  12. 2011 IBM Corporation Computer system energy management

    E-Print Network [OSTI]

    Shi, Weisong

    level EnergyScale Microcontroller IBM Systems Director · Policy management · Power & performance© 2011 IBM Corporation Computer system energy management Charles Lefurgy 28 July 2011 #12;© 2011 IBM Corporation2 Outline A short history of server power management POWER7 EnergyScale AMESTER power

  13. Performance Auditing of Energy Management Programs

    E-Print Network [OSTI]

    White, J. A.

    1988-01-01T23:59:59.000Z

    With the oil crisis of the 1970's, energy management programs became important to both the private and public sectors. But with the decrease of oil prices in the mid 1980's, interest in energy conservation programs has declined. Nevertheless, energy...

  14. Lead By Example with Smart Energy Management (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2009-07-01T23:59:59.000Z

    Brochure outlining the mission and activities of the Department of Energy's Federal Energy Management Program, which facilitates the Federal Government's implementation of sound, cost-effective energy management and investment practices to enhance the nation's energy security and environmental stewardship.

  15. "Turn-Key" Open Source Software Solutions for Energy Management...

    Energy Savers [EERE]

    "Turn-Key" Open Source Software Solutions for Energy Management of Small to Medium Sized Buildings (DE-FOA-0000822) "Turn-Key" Open Source Software Solutions for Energy Management...

  16. Energy Management - What Is Its Role in 1984?

    E-Print Network [OSTI]

    Hogeland, A. W.

    1984-01-01T23:59:59.000Z

    This paper explores the situation, as industry enters 1984, of energy management and the energy manager as compared to the 1973-83 period. It examines the trend toward local management responsibility for energy and appropriate goals in energy...

  17. Implementing an Energy Management Strategy for a Houston Refinery

    E-Print Network [OSTI]

    Wood, S. C.; Agrawal, R. K.; Canon, D.

    and maintained energy management program translates to PROFIT added directly to the BOTTOM LINE. Woodward-Clyde Consultants (WCC) recently implemented and energy management program at the Lyondell-Citgo Refinery in Houston, Texas. The basis of the program...

  18. federal energy management prog | netl.doe.gov

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Federal Energy Management Program The U.S. Department of Energy's Federal Energy Management Program (FEMP) plays a critical role in reducing energy use and increasing the use of...

  19. VA Energy Management Action Plan | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    VA Energy Management Action Plan VA Energy Management Action Plan Presentation covers the FUPWG Meeting, held on May 1-2, 2007 in Cape Canaveral, Florida. fupwgccdemers.pdf More...

  20. Web-Based Services for Building Energy Management - WEBE

    E-Print Network [OSTI]

    Paiho, S.; Pietilainen, J.; Ala-Juusela, M.

    2004-01-01T23:59:59.000Z

    Nowadays, internet can be accessed anywhere, and www-based applications are widespread. Utilizing internet also for energy management and commissioning purposes will be a future trend. A web-based service for building energy management, called Web...

  1. Facilitating Sound, Cost-Effective Federal Energy Management (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-12-01T23:59:59.000Z

    This fact sheet is an overview of the U.S. Department of Energy's Federal Energy Management Program (FEMP).

  2. Federal Energy Management Program Procedure for Notifying Congress...

    Broader source: Energy.gov (indexed) [DOE]

    Document displays the Federal Energy Management Program's Procedure for notifying Congress prior to awarding energy savings performance contracts (ESPCs) espccongressionalnotific...

  3. Partnering to achieve success in energy management

    SciTech Connect (OSTI)

    Scott, T.C.; Caldwell, S.J.

    1997-06-01T23:59:59.000Z

    The Army National Guard (ARNG) has over 110,000,000 square feet of heated, cooled and lighted facilities in all 50 States and the District of Columbia, Puerto Rico, the Virgin Islands, and Guam. Facilities mix runs the gamut from aviation hangers to weekend use armories. Utility costs are paid by Federal, State, and local agencies, and sometimes with different agencies sharing costs in the same facility. Facilities ages range from early 1900s converted horse stables to current ultra-modern office buildings. Each ARNG State energy manager has a formidable challenge and many innovative ideas for reducing energy costs have evolved. These ideas can be summed up in a concept referred to as {open_quotes}Partnering.{close_quotes} This concept of partnering at all levels of government has enabled the National Guard to lower its overall utility costs by 10% in the last three years. In its {open_quotes}Road Map to Facilities Energy Management,{close_quotes} an ARNG Handbook developed for Energy Managers, Partnering has a separate chapter with a mission statement of `Developing partnerships is to encourage agencies to work together to maximize energy savings and promote energy conservation awareness.` This presentation will cover how the Army National Guard has partnered with Federal, State, Regional, and local government agencies to achieve its Facility Energy Management Successes. Examples will be presented showing successful partnering with government agencies and partnerships with manufacturers and Energy Service Companies in conducting audits and ESPC contracting. The projects performed range from Eskimo Scout Armories in Alaska, installing Solar Hot Water heating in Colorado, and Waste Oil burners in Maine, developing plans for wind energy generators in Utah. and conducting lighting projects in Mississippi. Inventive partnering has allowed the Army National Guard to really stretch its utility dollars.

  4. Energy Management Strategies for Existing Buildings 

    E-Print Network [OSTI]

    Gilmer, L.

    2009-01-01T23:59:59.000Z

    Energy Management Strategies for Existing Buildings Energy efficiency in the built environment: in the United States, we have over 5 million existing buildings. These buildings consume a large percentage of our resources, one of which is energy.... In the coming years, as our demands increase, our infrastructure ages, and we set goals to reduce our green house gas emissions, building energy use plays a vital role. Our success in reducing our carbon footprint lies in our ability to determine energy use...

  5. Federal Energy Management Program Report Template

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport in RepresentativeDepartmentEnergyEnergy Management Program

  6. Examining Synergies between Energy Management and Demand Response: A

    E-Print Network [OSTI]

    LBNL-5719E Examining Synergies between Energy Management and Demand Response: A Case Study at Two Summary #12;Introduction Energy Management · · · · · · · · · · #12;Demand Response #12;#12;Bentley Prince-Project Personnel Changes #12;Enablement of Demand Response Capabilities due to Energy Management Improvement

  7. A MINIMAL MODEL OF ENERGY MANAGEMENT IN THE BRAIN

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    a minimal model of energy management inside a single cortical area, featuring local energy storage a simple model for energy man- agement within a single cortical area. By energy management, we mean a setA MINIMAL MODEL OF ENERGY MANAGEMENT IN THE BRAIN Florian A. Dehmelt, Christian K. Machens Group

  8. Optimal Energy Management Strategy including Battery Health through Thermal

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Optimal Energy Management Strategy including Battery Health through Thermal Management for Hybrid: Energy management strategy, Plug-in hybrid electric vehicles, Li-ion battery aging, thermal management, Pontryagin's Minimum Principle. 1. INTRODUCTION The interest for energy management strategy (EMS) of Hybrid

  9. IBM Systems Director Active Energy Manager Installation and User's Guide

    E-Print Network [OSTI]

    instructions for using IBM® Systems Director Active Energy Manager software to monitor and manage where powerIBM Systems Director Active Energy Manager Installation and User's Guide Version 4.3 #12;#12;IBM Systems Director Active Energy Manager Installation and User's Guide Version 4.3 #12;ii IBM Systems

  10. Seamless Energy Management Systems Part II: Development of Prototype

    E-Print Network [OSTI]

    Seamless Energy Management Systems Part II: Development of Prototype Core Elements Final Project System #12;#12;Seamless Energy Management Systems Part II: Development of Prototype Core Elements Final Center (PSERC) research project entitled "Seamless Energy Management Systems" (S-53G for 2013

  11. Examining Synergies between Energy Management and Demand Response: A Case Study at Two California Industrial Facilities

    E-Print Network [OSTI]

    Olsen, Daniel

    2013-01-01T23:59:59.000Z

    Capabilities due to Energy Management Improvement inSummary Introduction Energy Management Demand Responseand Processes Energy Management and Demand Response History

  12. Collecting Occupant Presence Data for Use in Energy Management of Commercial Buildings

    E-Print Network [OSTI]

    Rosenblum, Benjamin Tarr

    2012-01-01T23:59:59.000Z

    of fit between each energy management strategy and eachWayne Turner. 2009. Energy management handbook. 7th ed. TheData Needed for Energy Management Strategies .23

  13. Thinking Globally: How ISO 50001 - Energy Management can make industrial energy efficiency standard practice

    E-Print Network [OSTI]

    McKane, Aimee

    2010-01-01T23:59:59.000Z

    Comparison of National Energy Management Standards, prepared2007, Industrial Energy Management: Issues Paper, preparedMeeting: Using Energy Management Standards to stimulate

  14. Occupancy-Based Energy Management in Buildings: Final Report to Sponsors

    E-Print Network [OSTI]

    Sohn, Michael D.

    2010-01-01T23:59:59.000Z

    2009. Payne FW. Energy management control system handbook.5] F. W. Payne. Energy management control system hand- book.Occupancy- Based Energy Management Systems for Buildings:

  15. Strategic Energy Management Plan For Fort Buchanan, Puerto Rico

    SciTech Connect (OSTI)

    Parker, Steven A.; Hunt, W. D.

    2001-10-31T23:59:59.000Z

    This document reports findings and recommendations as a result of a design assistance project with Fort Buchanan with the goals of developing a Strategic Energy Management Plan for the Site. A strategy has been developed with three major elements in mind: 1) development of a strong foundation from which to build, 2) understanding technologies that are available, and 3) exploring financing options to fund the implementation of improvements. The objective of this report is to outline a strategy that can be used by Fort Buchanan to further establish an effective energy management program. Once a strategy is accepted, the next step is to take action. Some of the strategies defined in this Plan may be implemented directly. Other strategies may require the development of a more sophisticated tactical, or operational, plan to detail a roadmap that will lead to successful realization of the goal. Similarly, some strategies are not single events. Rather, some strategies will require continuous efforts to maintain diligence or to change the culture of the Base occupants and their efforts to conserve energy resources.

  16. Optimal Energy Management for a Hybrid Energy Storage System Combining Batteries and Double

    E-Print Network [OSTI]

    Paderborn, Universität

    Optimal Energy Management for a Hybrid Energy Storage System Combining Batteries and Double Layer storage for operation. High demands concerning power and energy density, small volume and weight is to combine storage technologies with complementary characteristics as a hybrid energy storage system. Thus

  17. DEMAND SIDE ENERGY MANAGEMENT AND CONSERVATION PROGRAM Measurement and Verification Program

    E-Print Network [OSTI]

    Hofmann, Hans A.

    DEMAND SIDE ENERGY MANAGEMENT AND CONSERVATION PROGRAM Measurement and Verification Program 4 operating hours for the lights in each room a. Assign a usage category to each room in all buildings (e electrical usage and savings in room by room spreadsheet d. Subtotal savings by building

  18. Conservation - The Keystone of Energy Management

    E-Print Network [OSTI]

    Read, R. C.

    1981-01-01T23:59:59.000Z

    THESE TECHNIQUES. INTRODUCTION THANK YOU FOR AFFORDING ME THE OPPORTUNITY TO PRESENT THE IH ENERGY MANAGEMENT PRO GRA~,.:. I BELIEVE IT IS THROUGH THIS TYPE OF FREE AND OPEN EXCHANGE THAT THE CAUSE OF ENERG Y MANAGEMENT IS MOST EFFICIENTLY ADVANCED... IN OURS. THE IH PROGRAt-.l INCLUDES: - SUPPORT OF TOP l\\llANAGEMENT DEFI1'iITE GOAL - PLANT SPECIFIC PLAN - PLANT ENERG Y COORDINATOR - $16 MILLION BUDGET NO PROGRAM CAN BE SUCCESSFUL IF NOT SUP PORTED BY THE BOSS. A PROGRAM WITHOUT A GOAL...

  19. Federal Energy Management Program | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers New Training on Energy ManagementAugustin2012)4EnergyEnergyFederal

  20. Federal Energy Management Program: BLCC5 Registration

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport in RepresentativeDepartmentEnergyEnergy Management ProgramFederal

  1. Optimization of the design and mode of operation of a QD laser for reducing the heat-to-bitrate ratio

    SciTech Connect (OSTI)

    Zhukov, A. E., E-mail: zhukale@gmail.com; Savelyev, A. V. [Russian Academy of Sciences, St. Petersburg Academic University-Nanotechnology Research and Education Center (Russian Federation)] [Russian Academy of Sciences, St. Petersburg Academic University-Nanotechnology Research and Education Center (Russian Federation); Maximov, M. V. [Russian Academy of Sciences, Ioffe Physical-Technical Institute (Russian Federation)] [Russian Academy of Sciences, Ioffe Physical-Technical Institute (Russian Federation); Kryzhanovskaya, N. V. [Russian Academy of Sciences, St. Petersburg Academic University-Nanotechnology Research and Education Center (Russian Federation)] [Russian Academy of Sciences, St. Petersburg Academic University-Nanotechnology Research and Education Center (Russian Federation); Gordeev, N. Yu.; Shernyakov, Yu. M. [Russian Academy of Sciences, Ioffe Physical-Technical Institute (Russian Federation)] [Russian Academy of Sciences, Ioffe Physical-Technical Institute (Russian Federation); Payusov, A. S.; Nadtochiy, A. M.; Zubov, F. I.; Korenev, V. V. [Russian Academy of Sciences, St. Petersburg Academic University-Nanotechnology Research and Education Center (Russian Federation)] [Russian Academy of Sciences, St. Petersburg Academic University-Nanotechnology Research and Education Center (Russian Federation)

    2013-08-15T23:59:59.000Z

    Heat dissipation under the high-speed modulation of quantum dot edge-emitting lasers is considered. It is shown that, for a given laser diode, there is a bias current at which the heat-to-bitrate ratio is minimized. Moreover, there exists a certain optimal optical loss of the laser cavity at which the lowest heat-to-bitrate ratio is provided for any design of edge-emitting lasers that can be fabricated from an epitaxial structure. The heat-to-bitrate ratio and the corresponding bitrate are numerically calculated and analytical expressions are derived. It is demonstrated that the heat-to-bitrate ratio of quantum dot edge-emitting lasers can be less than 0.4 pJ/bit at a bitrate exceeding 10 Gbit/s.

  2. An Operational Excellence Approach to Sustainable Energy Management

    E-Print Network [OSTI]

    McMullan, A.

    With the advent of persistently high energy costs, many organizations have renewed efforts to reduce energy use. Historically, energy cost reduction efforts have been run on a campaign basis, receiving priority in times of high energy prices, while...

  3. An Operational Excellence Approach to Sustainable Energy Management 

    E-Print Network [OSTI]

    McMullan, A.

    2009-01-01T23:59:59.000Z

    With the advent of persistently high energy costs, many organizations have renewed efforts to reduce energy use. Historically, energy cost reduction efforts have been run on a campaign basis, receiving priority in times of high energy prices, while...

  4. 2008 Federal Energy Management Program (FEMP) Market Report

    SciTech Connect (OSTI)

    Tremper, C.

    2009-07-01T23:59:59.000Z

    This report assesses the market for Federal Energy Management Program (FEMP) services as it existed in FY 2008. It discusses Federal energy management goal progress in FY 2008, and examines the environment in which agencies implemented energy management projects over the last three years. The report also discusses some recent events that will increase the market for FEMP services, and outlines FEMP's major strategies to address these changes in FY 2009 and beyond.

  5. Trip Prediction and Route-Based Vehicle Energy Management

    Broader source: Energy.gov (indexed) [DOE]

    Trip Prediction and Route-Based Vehicle Energy Management 2014 DOE Hydrogen Program and Vehicle Technologies Annual Merit Review June 18 th , 2014 Dominik Karbowski (PI), Aymeric...

  6. Lead by Example with Smart Energy Management FEMP (Revised Brochure)

    SciTech Connect (OSTI)

    Not Available

    2008-07-01T23:59:59.000Z

    This brochure provides the primary audience of Federal facility and energy managers with an accurate understanding of the services and assistance available through FEMP.

  7. Driving Water and Wastewater Utilities to More Sustainable Energy Management

    E-Print Network [OSTI]

    Ferrel, L.; Liner, B.

    2013-01-01T23:59:59.000Z

    . Finding alternative financial models such as Energy Services Performance Contracts (ESPC) is a good option to accomplish energy management goals in a timely and financially responsible method....

  8. Energy Management Strategies for Fast Battery Temperature Rise...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Very Cold Conditions Energy Management Strategies for Fast Battery Temperature Rise and Engine Efficiency Improvement at Very Cold Conditions 2010 DOE Vehicle Technologies and...

  9. Ocean Energy Technology Overview: Federal Energy Management Program (FEMP)

    SciTech Connect (OSTI)

    Not Available

    2009-07-01T23:59:59.000Z

    Introduction to and overview of ocean renewable energy resources and technologies prepared for the U.S. Department of Energy Federal Energy management Program.

  10. Federal Energy Management Program Contacts | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Contact information is available for Federal Energy Management Program (FEMP) leadership and staff members. The program is directed by Dr. Timothy Unruh. General Information...

  11. Sandia National Laboratories: real-time residential energy management...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    residential energy management and control Sandia Has Signed a Memorandum of Understanding with Case Western Reserve University On January 28, 2014, in Computational Modeling &...

  12. Sandia National Laboratories: real-time industrial energy management...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    grid integration of renewable-energy resources, real-time residential and industrial energy management and control, lifetime degradation and science and various forms of advanced...

  13. Federal Energy Management Program Procedure for Notifying Congress...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Federal Energy Management Program's Procedure for Notifying Congress Prior to Award of Energy Savings Performance Contracts (ESPCs) Although the Energy Independence and Security...

  14. Anaheim Public Utilities- Small Business Energy Management Assistance Program

    Broader source: Energy.gov [DOE]

    The Small Business Energy Management System Program provides participating customers with free electrical energy use evaluations, retrofit funding, and installation assistance. Anaheim Public...

  15. Federal Energy Management Program eTraining Core Courses

    Broader source: Energy.gov [DOE]

    Video summarizes the Federal Energy Management Program's (FEMP) eTraining courses available anytime online on the Whole Building Design Guide website.

  16. Federal Energy Management Program Training Offers IACET Continuing Education Units

    Broader source: Energy.gov [DOE]

    Video explains how the Federal Energy Management Program offers International Association for Continuing Education and Training (IACET) continuing education units for eTraining core courses.

  17. VOLTTRONTM as an Open Source Platform for Energy Management Applicatio...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Virginia Tech VOLTTRON TM as an Open Source Platform for Energy Management Applications HVAC Controllers Lighting Controllers Lighting circuit(s) Plug load Controllers July 23,...

  18. The Department of Homeland Security Energy Management Program

    Energy Savers [EERE]

    2, 2007 4 Structure The Energy Program is managed through the Energy Management Council (EMC) Formally established by Charter signed June 11, 2004 Reports to Chief...

  19. Save Energy Now Assessment Helps Expand Energy Management Program...

    Broader source: Energy.gov (indexed) [DOE]

    identify significant energy savings opportunities in their Dalton, Georgia, plant's steam system. Save Energy Now Assessment Helps Expand Energy Management Program at Shaw...

  20. DOE's New Checklist Helps Plants Assess Energy Management Activities...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    simple checklist can help a facility assess whether Superior Energy Performance (SEP) or ISO 50001 are practical next steps, or if foundational energy management activities...

  1. Energy Management and Information Systems Study - 2014 BTO Peer...

    Energy Savers [EERE]

    Management and Information Systems Study - 2014 BTO Peer Review Energy Management and Information Systems Study - 2014 BTO Peer Review Presenter: Jessica Granderson, Lawrence...

  2. Demonstration project in Energy Management Programs

    SciTech Connect (OSTI)

    Not Available

    1989-05-01T23:59:59.000Z

    The Energy Management Plan of the campuses developed under this project showed that there were a number of low-cost Energy Conservation Opportunities (ECO's) with a payback of under one year, (Short term Opportunities, STO). There were also other ECO's identified that had paybacks of more than one year. By combining these ECO's into one contract with the ESCO and paying for the costs of the ECO's by the savings resulting in the reduced energy bills, the University enhanced it's ability to carry out its mission of providing higher educational opportunities without spending money on non-educational activities. The low cost projects subsidize'' or provide leverage for the capital intensive, longer payback projects, to make an overall package that lends itself to innovative financing. JC Smith's contract also guarantees that the annual energy levels will not be increased.

  3. The Seven Keys to Success in Energy Management and Conservation

    E-Print Network [OSTI]

    Darby, D. F.

    1984-01-01T23:59:59.000Z

    This paper is a summary of the seven key elements of the Deere & Company Energy Management and Conservation Program. These elements have been found to be essential for the ultimate success of any company-wide energy management program. The process...

  4. Ph.D. Positions in "ICT for Sustainable Energy Management"

    E-Print Network [OSTI]

    Teschner, Matthias

    -edge applications for energy efficiency. We are developing and evaluating distributed systems for monitoring of complex systems Background in energy management and power systems is considered a plus Interest Ph.D. Positions in "ICT for Sustainable Energy Management" Key words: distributed information

  5. Energy management system for a rotary machine and method therefor

    DOE Patents [OSTI]

    Bowman, Michael John; Sinha, Gautam (NMN); Sheldon, Karl Edward

    2004-11-09T23:59:59.000Z

    In energy management system is provided for a power generating device having a working fluid intake in which the energy management system comprises an electrical dissipation device coupled to the power generating device and a dissipation device cooling system configured to direct a portion of a working fluid to the electrical dissipation device so as to provide thermal control to the electrical dissipation device.

  6. Maximizing Thermal Efficiency and Optimizing Energy Management (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-03-01T23:59:59.000Z

    Researchers at the Thermal Test Facility (TTF) on the campus of the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) in Golden, Colorado, are addressing maximizing thermal efficiency and optimizing energy management through analysis of efficient heating, ventilating, and air conditioning (HVAC) strategies, automated home energy management (AHEM), and energy storage systems.

  7. Trends in Energy Management Technology - Part 4: Review ofAdvanced Applications in Energy Management, Control, and InformationSystems

    SciTech Connect (OSTI)

    Yee, Gaymond; Webster, Tom

    2003-08-01T23:59:59.000Z

    In this article, the fourth in a series, we provide a review of advanced applications in Energy Management, Control, and Information Systems (EMCIS). The available features for these products are summarized and analyzed with regard to emerging trends in EMCIS and potential benefits to the Federal sector. The first article [1] covered enabling technologies for emerging energy management systems. The second article [2] serves as a basic reference for building control system (BCS) networking fundamentals and includes an assessment of current approaches to open communications. The third article [3] evaluated several products that exemplify the current state of practice in EMCIS. It is important for energy managers in the Federal sector to have a high level of knowledge and understanding of these complex energy management systems. This series of articles provides energy practitioners with some basic informational and educational tools to help make decisions relative to energy management systems design, specification, procurement, and energy savings potential.

  8. Facilitating Sound, Cost-Effective Federal Energy Management (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-03-01T23:59:59.000Z

    This fact sheet is an overview of the U.S. Department of Energy's Federal Energy Management Program (FEMP). The Federal Government, as the nation's largest energy consumer, has a tremendous opportunity and acknowledged responsibility to lead by example. The U.S. Department of Energy's (DOE's) Federal Energy Management Program (FEMP) plays a critical role in this effort. FEMP facilitates the Federal Government's implementation of sound, cost-effective energy management and investment practices to enhance the nation's energy security and environmental stewardship. FEMP does this by focusing on the needs of its Federal customers, delivering an array of services across a variety of program areas.

  9. Trends in Energy Management Technology: BCS Integration Technologies - Open Communications Networking

    E-Print Network [OSTI]

    Webster, Tom

    2002-01-01T23:59:59.000Z

    223. Trends in Energy Management Technology CBE/UC BerkeleyTrends in Energy Management Technology CBE/UC Berkeley FEMP/p. 6. Trends in Energy Management Technology CBE/UC Berkeley

  10. Multi-mode Energy Management for Multi-tier Server Tibor Horvath

    E-Print Network [OSTI]

    Skadron, Kevin

    Multi-mode Energy Management for Multi-tier Server Clusters Tibor Horvath tibor Charlottesville, VA 22904 ABSTRACT This paper presents an energy management policy for recon- figurable clusters General Terms Algorithms, Design, Experimentation, Management, Perfor- mance Keywords energy management

  11. What`s new in federal energy management: FEMP program overview. Federal Energy Management Program

    SciTech Connect (OSTI)

    NONE

    1996-08-01T23:59:59.000Z

    The US government has an enormous cost-saving opportunity as the largest energy user in the world. In 1994, the government spent $8 billion for its 500,000 buildings, it vehicles, and process energy. The US Department of Energy (DOE), Federal Energy Management Program (FEMP) reduces the cost of government and makes it work better through energy efficiency, use of renewable energy, and water conservation. FEMP leads Federal energy efficiency efforts and helps Federal energy managers identify and procure the best, most cost-effective energy-saving projects. It does this through proactive problem solving; an aggressive emphasis on increasing the number and quality of projects; and effective partnerships among agencies, utilities, the private sector, and states. Partnerships lead to increased motivation and education and reduced barriers to successful procurement. As the lead organization implementing legislation and Presidential direction for Federal energy efficiency, FEMP administers an interagency energy committee and task force and collaborates with the DOE national energy laboratories. FEMP works with energy service companies, energy savings product manufacturers, and utilities. This partnership will lead to a $1 billion investment by companies willing to invest in return for a share of the energy cost savings. With FEMP project financing, audits, training and technical assistance, and new technology demonstrations, agencies overcome obstacles to achieving widespread energy efficiency.

  12. Federal Government Energy Management Conservation Programs Reports...

    Office of Environmental Management (EM)

    Policy Act (NECPA, Pub. L. No. 95-619), as amended, and provide information on energy consumption in Federal buildings, operations, and vehicles. Compiled by the Federal...

  13. Peer Review of the Federal Energy Management Program Energy-Efficient...

    Broader source: Energy.gov (indexed) [DOE]

    Peer Review of the Federal Energy Management Program Energy-Efficient Product Procurement Portfolio Peer Review of the Federal Energy Management Program Energy-Efficient Product...

  14. Thinking Globally: How ISO 50001 - Energy Management can make industrial energy efficiency standard practice

    E-Print Network [OSTI]

    McKane, Aimee

    2010-01-01T23:59:59.000Z

    Thinking Globally: How ISO 50001 – Energy Management canThinking Globally: How ISO 50001 – Energy Management canOrganization for Standardization (ISO) has identified energy

  15. Incremental Implementation of Energy Management at Industrial Facilities

    E-Print Network [OSTI]

    Brown, M.; Key, G.

    2005-01-01T23:59:59.000Z

    The essential elements of a sustainable energy management program at industrial facilities are defined in the ANSI/MSE 2000 Management System for Energy standard document. Although many organizations have expressed interest in improving their energy...

  16. Design of a Computerized Energy Management System for Marine Applications 

    E-Print Network [OSTI]

    Russell, B. D.; Perry, L. W.; Gerloff, G. W.; Heller, R. P.; Pankonien, G.

    1982-01-01T23:59:59.000Z

    A computer-based energy management system for marine applications is presented. The problem of fuel-management for large diesel engines on board ship is discussed. The design of the computer hardware and software are presented including...

  17. Automated Home Energy Management Standing Technical Committee Presentation

    Broader source: Energy.gov [DOE]

    This presentation outlines the goals of the Automated Home Energy Management Standing Technical Committee, as presented at the Building America Spring 2012 Stakeholder meeting on February 29, 2012, in Austin, Texas.

  18. Corporate Energy Management: A Survey of Large Manufacturing Companies

    E-Print Network [OSTI]

    Norland, D. L.; Lind, L.

    Corporate practices regarding energy management vary substantially from one company to another. Some companies pay close attention to energy use throughout the corporation while others pay scant attention. This paper first describes what we call...

  19. Interactive Energy Management Tool (IEMT) for Arkansas Companies

    E-Print Network [OSTI]

    Pidugu, S. B.; Menhart, S.; Midturi, S.

    2005-01-01T23:59:59.000Z

    To benefit small and medium industries located in Arkansas, the Engineering Technology Department at the University of Arkansas at Little Rock (UALR) is currently developing an Interactive Energy Management Tool (IEMT) for Arkansas Companies...

  20. The Role of Benchmarking in Promoting Strong Energy Management Systems

    E-Print Network [OSTI]

    Tunnessen, W.

    2010-01-01T23:59:59.000Z

    The significance of formalized energy management practices and programs in driving and sustaining energy efficiency improvements within the industrial sector has become more widely recognized over the past several years. The release of the ISO 50001...

  1. Energy Management Degree Specialization at Texas A&M University

    E-Print Network [OSTI]

    Murphy, W. E.; O'Neal, D. L.; Heffington, W. M.; Turner, W. D.; Somasundaram, S.; Holmes, R. E.

    The Department of Mechanical Engineering at Texas A&M offers unique degree programs with a specialization in energy management. The most popular of the degree offered is a professional degree, the Master of Engineering, which blends technical...

  2. Linking Continuous Energy Management and Open Automated Demand Response

    E-Print Network [OSTI]

    Piette, Mary Ann

    2009-01-01T23:59:59.000Z

    building electric load management concepts and faster scale dynamic DR using open automation systems.systems are being designed to be compatible with existing open building automationbuilding controls, weather sensitivity and occupancy patterns. Automation - Historically many energy management systems

  3. Harrison Radiator Division's Energy Management, Reporting and Accounting System 

    E-Print Network [OSTI]

    Goubeaux, R. J.

    1986-01-01T23:59:59.000Z

    Energy management is essential for obtaining the lowest possible product manufacturing cost. Many systems have been created over the years to manage the energy used in manufacturing. However, for a variety of reasons, most of them never reached...

  4. Energy Management Services for the Industrial Market Segment at TVA

    E-Print Network [OSTI]

    Hamby, R. E.; Knight, V. R.

    1984-01-01T23:59:59.000Z

    The Tennessee Valley Authority has provided energy management surveys (EMSs) to commercial and industrial power consumers since 1979. A significant number of EMSs have been performed to a variety of industry types and sizes. As in all developmental...

  5. Intelligent energy management agent for a parallel hybrid vehicle 

    E-Print Network [OSTI]

    Won, Jong-Seob

    2004-09-30T23:59:59.000Z

    This dissertation proposes an Intelligent Energy Management Agent (IEMA) for parallel hybrid vehicles. A key concept adopted in the development of an IEMA is based on the premise that driving environment would affect fuel ...

  6. The Role of Benchmarking in Promoting Strong Energy Management Systems 

    E-Print Network [OSTI]

    Tunnessen, W.

    2010-01-01T23:59:59.000Z

    The significance of formalized energy management practices and programs in driving and sustaining energy efficiency improvements within the industrial sector has become more widely recognized over the past several years. ...

  7. Design of a Computerized Energy Management System for Marine Applications

    E-Print Network [OSTI]

    Russell, B. D.; Perry, L. W.; Gerloff, G. W.; Heller, R. P.; Pankonien, G.

    1982-01-01T23:59:59.000Z

    A computer-based energy management system for marine applications is presented. The problem of fuel-management for large diesel engines on board ship is discussed. The design of the computer hardware and software are presented including...

  8. Contract Management Using Industrial Energy Management & Reporting Systems

    E-Print Network [OSTI]

    Robinson, J. E.

    2011-01-01T23:59:59.000Z

    Energy Management and Reporting Systems (EMRS) are rule-based control systems with a record of reducing energy usage and CO2e emissions while optimizing electrical generation in a real time environment. The rule set successfully optimizes energy...

  9. Development of an International Standard for Energy Management

    E-Print Network [OSTI]

    Meffert, B.; McKane, A.

    International interest in energy management is driving the development of an ISO management standard. The U.S. DOE is leading this effort in partnership with other countries. The speakers will describe the development of an international management...

  10. Energy Use Analysis for the Federal Energy Management Program 

    E-Print Network [OSTI]

    Mazzucchi, R. P.; Devine, K. D.

    1988-01-01T23:59:59.000Z

    -efficient, the Federal Energy Management Program (FEMP) endeavors to improve the technical basis for such performance-based contracting. Specific tasks include the development of improved energy use baselining methods, refinement of a simplified energy analysis method...

  11. Leading by Example with Smart Energy Management (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-12-01T23:59:59.000Z

    The Federal Energy Management Program facilitates the Federal Government?s implementation of sound, cost-effective energy management and investment practices to enhance the nation?s energy security and environmental stewardship. FEMP does this by focusing on the needs of its Federal customers, delivering an array of products grouped into project transaction services, applied technology services, and decision support services. This document outlines FEMP services and programs.

  12. Annual report to Congress on Federal Government Energy Management and Conservation Programs

    SciTech Connect (OSTI)

    Not Available

    1994-02-01T23:59:59.000Z

    This report on Federal Energy Management for Fiscal year (FY) 1992 provides information on energy consumption in Federal buildings and operations and documents activities conducted by Federal agencies to meet the statutory requirements of Title V, Part 3, of the National Energy Conservation Policy Act (NECPA), as amended, 42 U.S.C. 8251-8261, and Title VIII of NECPA, 42 U.S.C. 8287-8287b. This report also describes the energy conservation and management activities of the Federal Government under the authorization of section 381 of the Energy Policy and Conservation Act (EPCA), as amended, 42 U.S.C. 6361. Implementation activities undertaken during FY 1992 by the Federal agencies under Executive Order 12759 on Federal Energy Management are also described in this report.

  13. Energy Management Strategies for Existing Buildings

    E-Print Network [OSTI]

    Gilmer, L.

    to improve, and how the future work force will need to prepare itself to respond. ESL-IC-09-11-11 Proceedings of the Ninth International Conference for Enhanced Building Operations, Austin, Texas, November 17 - 19, 2009 ...

  14. Energy Management Experience in Public Schools

    E-Print Network [OSTI]

    McClure, J. D.

    1984-01-01T23:59:59.000Z

    Public schools have a continuing dilemma of escalating energy costs, deferred maintenance, and enrollment shift. Schools have experienced difficulty in dealing with budgeting and subsequent control of maintenance and operating costs. It is essential...

  15. Energy Management Experience in Public Schools 

    E-Print Network [OSTI]

    McClure, J. D.

    1984-01-01T23:59:59.000Z

    Public schools have a continuing dilemma of escalating energy costs, deferred maintenance, and enrollment shift. Schools have experienced difficulty in dealing with budgeting and subsequent control of maintenance and operating costs. It is essential...

  16. Diss. ETH No. 21036 Optimal Energy Management

    E-Print Network [OSTI]

    Lygeros, John

    Federal Office of Energy and Siemens Schweiz AG for the co-funding of my project. I am further indebted for their support and helpful discussions, namely Ivan L¨otscher, Markus Gwerder and Bruno Illi of Siemens Building and operating constraints are transformed into mixed-integer linear in- equalities to integrate them

  17. Final Scientific/Technical Report: Context-Aware Smart Home Energy Manager (CASHEM)

    SciTech Connect (OSTI)

    Foslien, Wendy K; Curtner, Keith L

    2013-01-15T23:59:59.000Z

    Because of growing energy demands and shortages, residential home owners are turning to energy conservation measures and smart home energy management devices to help them reduce energy costs and live more sustainably. In this context, the Honeywell team researched, developed, and tested the Context Aware Smart Home Energy Manager (CASHEM) as a trusted advisor for home energy management. The project focused on connecting multiple devices in a home through a uniform user interface. The design of the user interface was an important feature of the project because it provided a single place for the homeowner to control all devices and was also where they received coaching. CASHEM then used data collected from homes to identify the contexts that affect operation of home appliances. CASHEM�s goal was to reduce energy consumption while keeping the user�s key needs satisfied. Thus, CASHEM was intended to find the opportunities to minimize energy consumption in a way that fit the user�s lifestyle.

  18. Driving Energy Performance with Energy Management Teams 

    E-Print Network [OSTI]

    Younghein, M.; Tunnessen, W.

    2006-01-01T23:59:59.000Z

    Washington, DC forms of energy-related risks should not be discounted as an issue only affecting companies where energy is a major percentage of total costs. As the International Energy Agency underscores in its 2004 World Energy Outlook, “short... to achieve their annual average 4% reduction in energy intensity. The 3M energy team includes members from the facility engineering, finance, environmental, plant operations, and research & development divisions, as well as their suppliers and vendors...

  19. Integrating Energy Management and Lean Manufacturing

    E-Print Network [OSTI]

    Stocki, M.

    Reduced Building Energy through Lean Case Study Facility floor space typically must be heated, ventilated, and illuminated. When space runs outs, a facility usually looks to expand by adding floor space. A farm equipment manufacturer was facing just... Procedures to optimize operational and production tasks ? Encouraging energy efficiency through the use of Visual Dashboards (sample in Figure 3). ? Root cause analysis to determine the underlying causes (and possible solutions) of energy wastes in a...

  20. Local Area Networks - Applications to Energy Management

    E-Print Network [OSTI]

    Bakken, B. M.

    1984-01-01T23:59:59.000Z

    resources with ott and controls a handling unit. 1 control fans. But with, or use infor operations. When r* it will comunicate part. of a distributed ra pr * v. cur rrrbsgr a*=" oJ.a*rlu, with a "head endw computer (as system), but its..., and other types of control. When Unit Two detects a change in outdoor ail- temperature, it stores the new temperature in its memory, and also sends a message to Unit One letting it know the new value of outdoor air temperature. This allows Unit One...

  1. Total Energy Management in General Motors 

    E-Print Network [OSTI]

    DeKoker, N.

    1979-01-01T23:59:59.000Z

    these and any other conditions. PLANNING FOR THE FUTURE GM is also deeply involved in trying to develop effective energy planning guidelines to meet the long term planning needs of our plants. One approach has been to review the energy outlook projections... by a number of organizations and agencies and apply these pro jections to GM operations. Table IV contains the energy outlook projections to 1990 by Exxon, Shell and the U.S. Department of Energy. Also shown is the actual energy consumed by form...

  2. Intelligent energy management agent for a parallel hybrid vehicle

    E-Print Network [OSTI]

    Won, Jong-Seob

    2004-09-30T23:59:59.000Z

    INTELLIGENT ENERGY MANAGEMENT AGENT FOR A PARALLEL HYBRID VEHICLE A Dissertation by JONG-SEOB WON Submitted to the O ce of Graduate Studies of Texas A&M University in partial ful llment of the requirements for the degree of DOCTOR OF PHILOSOPHY May... 2003 Major Subject: Mechanical Engineering INTELLIGENT ENERGY MANAGEMENT AGENT FOR A PARALLEL HYBRID VEHICLE A Dissertation by JONG-SEOB WON Submitted to Texas A&M University in partial ful llment of the requirements for the degree of DOCTOR...

  3. Optimal Privacy-Preserving Energy Management for Smart Meters

    E-Print Network [OSTI]

    Reisslein, Martin

    Optimal Privacy-Preserving Energy Management for Smart Meters Lei Yang, Xu Chen, Junshan Zhang Abstract--Smart meters, designed for information collection and system monitoring in smart grid, report a tradeoff between the smart meter data privacy and the electricity bill. In general, a major challenge

  4. Driving Water and Wastewater Utilities to More Sustainable Energy Management 

    E-Print Network [OSTI]

    Ferrel, L.; Liner, B.

    2013-01-01T23:59:59.000Z

    conservation and focus on overall energy management. This roadmap leverages the framework developed in the electric power sector to move to smart grid technology: the smart grid maturity model (SGMM). The basis of this material originated at a workshop of water...

  5. 190 India Infrastructure Report 2006 URBAN ENERGY MANAGEMENT

    E-Print Network [OSTI]

    Columbia University

    to reach you news about your city and your area, especially to gauge when electricity might be restored190 India Infrastructure Report 2006 URBAN ENERGY MANAGEMENT Prem K. Kalra and Rajiv Shekhar 9 I ndia's cities are the engines of her economic growth. To provide an environment conducive to the buzz

  6. advanced energy management: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    energy management First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Graduate Catalog 2013-2014 Advanced...

  7. New Technology Demonstration Program FEMPFederal Energy Management Program

    E-Print Network [OSTI]

    Efficiency and Renewable Energy, Federal Energy Management Program, of the U.S. Department of Energy under federal facilities, the fastest growing end-use of electric energy is found in concentrations of computing to their agency mission will present a serious challenge to meeting the aggressive new energy efficiency goals

  8. Joint Energy Management and Resource Allocation in Rechargeable Sensor Networks

    E-Print Network [OSTI]

    Sinha, Prasun

    Joint Energy Management and Resource Allocation in Rechargeable Sensor Networks Ren-Shiou Liu CSE, The Ohio State University Email: rsliu@cse.ohio-state.edu Prasun Sinha CSE, The Ohio State University Email: prasun@cse.ohio-state.edu Can Emre Koksal ECE, The Ohio State University Email: koksal

  9. Selection and Evaluation of Energy Management and Control Systems

    E-Print Network [OSTI]

    Moderow, R. R.

    1982-01-01T23:59:59.000Z

    1. Why have many Energy Management and Control (EMC) systems failed to be truly cost effective? 2. What are the inherent problems in the selection of an EMC system? 3. What should an EMC system have to offer before being seriously considered...

  10. Leveraging residential energy management through the Internet of Things

    E-Print Network [OSTI]

    Leveraging residential energy management through the Internet of Things Markus Weiss Engineering into the residential environment contribute significantly to today's energy consumption. However, there exists a lack be achieved with adequate information at hand. Thus, conserving energy in residential spaces requires making

  11. Home Energy Management as a Service over Networking Platforms

    E-Print Network [OSTI]

    Al Faruque, Mohammad Abdullah

    for the residential sector (22% of the U.S. primary energy). Moreover, towards this goal, U.S. Department of Energy Energy Management (HEM) may be used to improve the energy consumption in the residential buildings and existing residential and commercial buildings to reduce the national energy consumption [3]. Therefore

  12. ESSES 2003 2003, Carla Schlatter Ellis Energy Management

    E-Print Network [OSTI]

    Ellis, Carla

    1 ESSES 2003© 2003, Carla Schlatter Ellis Energy Management at Upper Levels of System Design Carla Schlatter Ellis Systems & Architecture Milly Watt Project 2ESSES 2003© 2003, Carla Schlatter Ellis Energy Watt Project #12;2 3ESSES 2003© 2003, Carla Schlatter Ellis Energy should be a "first class" resource

  13. Power and Energy Management for Server Systems Ricardo Bianchini

    E-Print Network [OSTI]

    Bianchini, Ricardo

    , of servers and supporting cooling infrastructures. Research on power and energy management for servers can requests coming from remote clients or other servers. Common examples are Web and application servers consumption have become key concerns in data centers. The peak power consumption dictates the required cooling

  14. Energy Management for an Electric Vehicle Based on Combinatorial Modeling

    E-Print Network [OSTI]

    Boyer, Edmond

    energy sources (fuel cells, photovoltaic panels, batteries, supercapacitors) with different of the energy system The energy chain of the vehicle concerned is composed of a Fuel Cell System (FCS) using Toulouse, France Abstract This paper describes the process of electrical energy management and optimization

  15. Energy Management Practices at Dalls/Fort Worth International Airport

    E-Print Network [OSTI]

    Dennis, J. R.

    2013-01-01T23:59:59.000Z

    of the Airport?s energy conservation building codes and standards. Proposed Street Light for Southgate Fanwall AHU (TRIP) Energy Management Practices at DFW Airport, October 9, 2013 Demand-Side Management (cont.) ? Continuous Commissioning? ? Optimizes... Management Section ? Structure & Mission ? Supply-Side Management ? Reliability ? Cost (Risk) mitigation ? Environmental stewardship ? Demand-Side Management ? Energy monitoring ? Energy audits ? Energy standards ? Continuous Commissioning...

  16. Our Favorite Energy Management Opportunities: A Review of Over 150 Energy Audits of Industrial Firms

    E-Print Network [OSTI]

    Webb, R. E.; Lewis, M.; Spivey, V.; Knight, N.; Turner, W. C.

    For five years the Oklahoma Industrial Energy Management Program at Oklahoma State University has been serving industry by offering energy audits and energy management conferences. To date, more than 50 conferences and 170 energy audits have been...

  17. Job Task Analysis: Energy Manager; November 2013 - December 2014

    SciTech Connect (OSTI)

    Woodley, C. D.

    2015-01-01T23:59:59.000Z

    This report describes the process for and results of a comprehensive job task analysis of Energy Managers. This study was performed by Professional Testing on behalf of the National Renewable Energy Laboratory (NREL). The competency (domains, tasks and associated knowledge) list, which defines the work performed by practitioners, was initially developed by a representative panel of practitioners during a meeting held on January 22?24, 2014 in Orlando Florida. Following the identification of the job tasks and associated knowledge and skills, a validation survey was conducted of the finding of the JTA and the results of the validation study were reviewed by a representative panel of practitioners during a conference call held on June 2, 2014. The committee finalized the JTA and examination blueprints for the Energy Manager credential scheme based on the survey results.

  18. Peer Review of the Federal Energy Management Program Energy-Efficient Product Procurement Portfolio

    Broader source: Energy.gov [DOE]

    Document details the peer review of the Federal Energy Management Program Energy-Efficient Product Procurement portfolio.

  19. Federal Energy Management Program Recovery Act Project Stories | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport in RepresentativeDepartmentEnergyEnergy Management Program Technicalof

  20. Near Optimal Demand-Side Energy Management Under Real-time Demand-Response Pricing

    E-Print Network [OSTI]

    Boutaba, Raouf

    Near Optimal Demand-Side Energy Management Under Real-time Demand-Response Pricing Jin Xiao, Jae--In this paper, we present demand-side energy manage- ment under real-time demand-response pricing as a task, demand-response, energy management I. INTRODUCTION The growing awareness of global climate change has

  1. A real time neural energy management strategy for a hybrid pneumatic engine

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    A real time neural energy management strategy for a hybrid pneumatic engine Guillaume Colin G.bloch@esstin.uhp-nancy.fr} Abstract: Various energy management strategies for a hybrid pneumatic engine are reviewed and a real time Recognition. Keywords: energy management strategy, fuel saving, hybrid vehicle, hybrid pneumatic engine

  2. Division of IT Convergence Engineering Optimal Demand-Side Energy Management Under

    E-Print Network [OSTI]

    Boutaba, Raouf

    Division of IT Convergence Engineering Optimal Demand-Side Energy Management Under Real-time Demand of appliance specific adapters. Designed and implemented GHS Modeled the demand-side energy management problem (NP-hard) Designed a scheduling algorithm for demand side energy management Showed that our

  3. Stochastic Modeling and Optimization for Energy Management in Multi-Core Systems

    E-Print Network [OSTI]

    Tasiran, Serdar

    1 Stochastic Modeling and Optimization for Energy Management in Multi-Core Systems: A Video and optimization framework which leads to effective energy management policies. At the heart of this framework lie to obtain optimal energy management policies. These policies minimize the average energy consumption using

  4. Efficient Energy Management Policies for Networks with Energy Harvesting Sensor Nodes

    E-Print Network [OSTI]

    Sharma, Vinod

    Efficient Energy Management Policies for Networks with Energy Harvesting Sensor Nodes Vinod Sharma at that time at the node. For such networks we develop efficient energy management policies. First for the largest possible data rate. Next we obtain energy management policies which minimize the mean delay

  5. On The Design and Implementation of a Home Energy Management System

    E-Print Network [OSTI]

    Boutaba, Raouf

    energy management at home is key and an integral part of the future Smart Grid. In this paper, we present the key issues of home energy management in Smart Grid: a holistic management solution, improved device energy management and show the results in simulation studies. Index Terms--smart grid, home energy

  6. Energy management of HEV to optimize fuel consumption and pollutant emissions

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    AVEC'12 Energy management of HEV to optimize fuel consumption and pollutant emissions Pierre Michel, several energy management strategies are proposed to optimize jointly the fuel consumption and pollutant-line strategy are given. Keywords: Hybrid Electric Vehicle (HEV), energy management, pollution, fuel consumption

  7. Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

    E-Print Network [OSTI]

    Stadler, Michael

    2010-01-01T23:59:59.000Z

    Issue on Microgrids and Energy Management 3. Marnay, C. , G.Issue on Microgrids and Energy Management 15. PG&E tariffs (Issue on Microgrids and Energy Management Figures Figure 1.

  8. Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

    E-Print Network [OSTI]

    Stadler, Michael

    2010-01-01T23:59:59.000Z

    Deru, D. Crawley (2006), “Zero Energy Buildings: A Criticaland Energy Management in Zero-Net-Energy Buildings Michaeland Energy Management in Zero-Net-Energy Buildings 1 Michael

  9. The Wide-area Energy Management System Phase 2 Final Report

    SciTech Connect (OSTI)

    Lu, Ning; Makarov, Yuri V.; Weimar, Mark R.

    2010-08-31T23:59:59.000Z

    The higher penetration of intermittent generation resources (including wind and solar generation) in the Bonneville Power Administration (BPA) and California Independent System Operator (CAISO) balancing authorities (BAs) raises issue of requiring expensive additional fast grid balancing services in response to additional intermittency and fast up and down power ramps in the electric supply system. The overall goal of the wide-area energy management system (WAEMS) project is to develop the principles, algorithms, market integration rules, a functional design, and a technical specification for an energy storage system to help cope with unexpected rapid changes in renewable generation power output. The resulting system will store excess energy, control dispatchable load and distributed generation, and utilize inter-area exchange of the excess energy between the California ISO and Bonneville Power Administration control areas. A further goal is to provide a cost-benefit analysis and develop a business model for an investment-based practical deployment of such a system. There are two tasks in Phase 2 of the WAEMS project: the flywheel field tests and the battery evaluation. Two final reports, the Wide-area Energy Management System Phase 2 Flywheel Field Tests Final Report and the Wide-area Energy Storage and Management System Battery Storage Evaluation, were written to summarize the results of the two tasks.

  10. Wireless Sensor Network for Advanced Energy Management Solutions

    SciTech Connect (OSTI)

    Peter J. Theisen; Bin Lu, Charles J. Luebke

    2009-09-23T23:59:59.000Z

    Eaton has developed an advanced energy management solution that has been deployed to several Industries of the Future (IoF) sites. This demonstrated energy savings and reduced unscheduled downtime through an improved means for performing predictive diagnostics and energy efficiency estimation. Eaton has developed a suite of online, continuous, and inferential algorithms that utilize motor current signature analysis (MCSA) and motor power signature analysis (MPSA) techniques to detect and predict the health condition and energy usage condition of motors and their connect loads. Eaton has also developed a hardware and software platform that provided a means to develop and test these advanced algorithms in the field. Results from lab validation and field trials have demonstrated that the developed advanced algorithms are able to detect motor and load inefficiency and performance degradation. Eaton investigated the performance of Wireless Sensor Networks (WSN) within various industrial facilities to understand concerns about topology and environmental conditions that have precluded broad adoption by the industry to date. A Wireless Link Assessment System (WLAS), was used to validate wireless performance under a variety of conditions. Results demonstrated that wireless networks can provide adequate performance in most facilities when properly specified and deployed. Customers from various IoF expressed interest in applying wireless more broadly for selected applications, but continue to prefer utilizing existing, wired field bus networks for most sensor based applications that will tie into their existing Computerized Motor Maintenance Systems (CMMS). As a result, wireless technology was de-emphasized within the project, and a greater focus placed on energy efficiency/predictive diagnostics. Commercially available wireless networks were only utilized in field test sites to facilitate collection of motor wellness information, and no wireless sensor network products were developed under this project. As an outgrowth of this program, Eaton developed a patented energy-optimizing drive control technology that is complementary to a traditional variable frequency drives (VFD) to enable significant energy savings for motors with variable torque applications, such as fans, pumps, and compressors. This technology provides an estimated energy saving of 2%-10% depending on the loading condition, in addition to the savings obtained from a traditional VFD. The combination of a VFD with the enhanced energy-optimizing controls will provide significant energy savings (10% to 70% depending on the load and duty cycle) for motors that are presently connected with across the line starters. It will also provide a more favorable return on investment (ROI), thus encouraging industries to adopt VFDs for more motors within their facilities. The patented technology is based on nonintrusive algorithms that estimate the instantaneous operating efficiency and motor speed and provide active energy-optimizing control of a motor, using only existing voltage and current sensors. This technology is currently being commercialized by Eaton’s Industrial Controls Division in their next generation motor control products. Due to the common nonintrusive and inferential nature of various algorithms, this same product can also include motor and equipment condition monitoring features, providing the facility owner additional information to improve process uptime and the associated energy savings. Calculations estimated potential energy savings of 261,397GWh/Yr ($15.7B/yr), through retrofitting energy-optimizing VFDs into existing facilities, and incorporating the solution into building equipment sold by original equipment manufacturers (OEMs) and installed by mechanical and electrical contractors. Utilizing MCSA and MPSA for predictive maintenance (PM) of motors and connected equipment reduces process downtime cost and the cost of wasted energy associated with shutting down and restarting the processes. Estimated savings vary depending on the industry segment and equi

  11. Federal Energy Management Program (FEMP) Technical Assistance Request

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers New Training on Energy ManagementAugustin2012)4 News5Management CasePortal

  12. Federal Energy Management Program Technical Assistance | Department of

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers New Training on Energy ManagementAugustin2012)4EnergyEnergy Technical

  13. Federal Energy Management: Helping Agencies Achieve Savings | Department of

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers New Training on Energy6 Federal Energy Management Success Stories en

  14. Energy Management Company Association EMCA | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJump to:Emminol Jump to:EnergEnergy 21EnergyEnergy Management

  15. Federal Energy Management Program Recovery Act Technical Assistance

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport in RepresentativeDepartmentEnergyEnergy Management Program TechnicalofProjects

  16. Federal Energy Management Program Report Template | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport in RepresentativeDepartmentEnergyEnergy Management ProgramFederal Energy

  17. Interagency Energy Management Task Force | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking of BlytheDepartmentEnergyDemonstration DomesticEnergy Management Task

  18. ACC100 Crash Energy Management | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: The Future of1 A Strategic Framework for SMRA View from00 Crash Energy Management

  19. What`s new in federal energy management: FEMP program overview. Federal energy saver showcases

    SciTech Connect (OSTI)

    NONE

    1996-08-01T23:59:59.000Z

    To promote widespread Federal energy efficiency, agencies are showcasing their best energy efficiency, water conserving, and solar and other renewable energy technologies. To highlight these successful energy-efficient projects, Executive Order 12902 directs agencies to designate at least one newly constructed or existing building as a showcase facility. At existing facilities, agencies must also try to incorporate cogeneration and indoor air quality improvements. Agencies are directed to develop and implement effective plans to make these showcase projects happen. Project successes will show the strength of partnering with other agencies, energy services companies, utilities, and national laboratories, and of using the US Department of Energy Federal Energy Management Program (FEMP) as a resource. The goal is Federal facilities operating at peak efficiency. A Federal Energy Saver Showcase plaque is prominently displayed at each showcase site, notifying visitors they are entering a government building that successfully conserves energy and water and saves taxpayer dollars.

  20. California Federal Facilities: Rate-Responsive Buidling Operating for Deeper Cost and Energy Savings

    Broader source: Energy.gov [DOE]

    Fact sheet from the Federal Energy Management Program (FEMP) describes rate-responsive building operations for cost and energy savings in California federal facilities.

  1. Facilities Operations, Planning, and Engineering Services

    E-Print Network [OSTI]

    McLaughlin, Richard M.

    Facilities Operations, Planning, and Design Engineering Services Energy Management & Water and In- house Engineering Mechanical Electrical Engineering Data Analysis Construction Services In Conservation Capital Project-Bldg Systems Review Commissioning BSL3/DLAM Engineer Building Systems Engineering

  2. Engine optimal operation lines for power-split hybrid electric vehicles

    E-Print Network [OSTI]

    Papalambros, Panos

    . Keywords: hybrid electric vehicle, power split, energy management strategy, optimal operation lineEngine optimal operation lines for power-split hybrid electric vehicles Kukhyun Ahn* and P Y of degrees of freedom in energy management. Optimization problems for the two operation modes are formulated

  3. Energy Management A Program of Energy Conservation for the Community College Facility

    E-Print Network [OSTI]

    Authors, Various

    2011-01-01T23:59:59.000Z

    I [] c== l-~~-~ Energy Conservation Checklist and BuildingFREEZERS Some important energy conservation principles thatEnergy Management and Energy Conservation Practices for the

  4. Federal Energy Management Program Procedure for Notifying Congress Prior to Award of ESPCs

    Broader source: Energy.gov [DOE]

    Document displays the Federal Energy Management Program’s Procedure for notifying Congress prior to awarding energy savings performance contracts (ESPCs)

  5. Thinking Globally: How ISO 50001 - Energy Management can make industrial energy efficiency standard practice

    E-Print Network [OSTI]

    McKane, Aimee

    2010-01-01T23:59:59.000Z

    integration of energy management into business practices. ItIndustrial Energy Efficiency The principal business of anIn addition, business metrics such as energy performance

  6. Urban energy management: a course on the administration of public energy programs. An instructor's guide

    SciTech Connect (OSTI)

    Mandelbaum, Dr., Len; Olsen, Dr., Marvin; Hyman, Dr., Barry; Sheridan, Mimi; Dahlberg, Judy; O'Brien, Jeremy

    1980-12-01T23:59:59.000Z

    The course provides local government administrators, staff, and students with the background knowledge to deal with a broad range of energy management concerns and is not to train technical energy conservation specialists. Section II contains the Instructor's Guide and Section III provides the Student Outlines and Handouts on the following subjects: The Energy Problem; National Energy Politics and Programs; State and Local Energy Programs; Techniques of Energy Planning; Techniques of Energy Conservation; Techniques of Renewable Energy Production; Strategies for Voluntary Energy Management; Strategies for Finan. Energy Management; and Strategies for Mandatory Energy Management. (MCW)

  7. Dynamic Programming Applied to Investigate Energy Management Strategies for a Plug-in HEV

    SciTech Connect (OSTI)

    O'Keefe. M. P.; Markel, T.

    2006-11-01T23:59:59.000Z

    This paper explores two basic plug-in hybrid electric vehicle energy management strategies: an electric vehicle centric control strategy and an engine-motor blended control strategy.

  8. Strategic Energy Management Plan for the Santa Ynez Band of Chumash...

    Office of Scientific and Technical Information (OSTI)

    Strategic Energy Management Plan for the Santa Ynez Band of Chumash Indians Re-direct Destination: This plan outlines the Santa Ynez Band of Chumash Indians' comprehensive energy...

  9. FEMP (Federal Energy Management Program) presents alternative financing guidance memoranda

    SciTech Connect (OSTI)

    NONE

    1998-06-01T23:59:59.000Z

    Utility financing of energy efficient measures becomes easier to accomplish with the two new alternative financing guidance memoranda, released April 17, 1998, that address the use of utility incentives for Federal facilities. The memoranda have been approved by the Alternative Financing Guidance Committee on the Interagency Energy Management Task Force. The memoranda include: (1) Policy Statement No. 001: Authority to Sole Source Utility Service Contracts as Referenced in Section 152 of the Energy Policy Act (EPACT) of 1992; and (2) Policy Statement No. 002: Congressional Notification for Utility Projects Under the Authority of Section 152 of the Energy Policy Act (EPACT) of 1992. The purpose for developing the financing memoranda was to address specific issues within current Federal procurement regulations that require clarification or guidance. This new guidance will allow for increased use of utility incentives as a means of financing energy efficient and life cycle cost-effective projects in Federal facilities.

  10. Energy Management Strategy for Commercial Buildings Integrating PV and Storage Systems

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Energy Management Strategy for Commercial Buildings Integrating PV and Storage Systems He ZHANG1 by using the solution proposed. Keywords: Photovoltaic (PV) systems, fuzzy logic, storage system, energy connected to the power network and associated to photovoltaic and storage system. Some energy management

  11. Optimal Energy Management for a Hybrid Energy Storage System for Electric Vehicles Based on

    E-Print Network [OSTI]

    Paderborn, Universität

    Optimal Energy Management for a Hybrid Energy Storage System for Electric Vehicles Based are used as energy storage. The size of the battery depends not only on the driving range, but also Deterministic Dynamic Programming. To determine an energy management to control the power flows to the storage

  12. Distributed Wireless Control for Building Energy Management Alan Marchiori and Qi Han

    E-Print Network [OSTI]

    Han, Qi "Chee"

    Distributed Wireless Control for Building Energy Management Alan Marchiori and Qi Han Department building energy management systems are es- sential to enabling the development of mass-market, low- energy to the total energy efficiency. As building technologies and materi- als improve, the relative impact

  13. Energy Management Strategy for a Parallel Hybrid Electric Truck Chan-Chiao Lin1

    E-Print Network [OSTI]

    Grizzle, Jessy W.

    Energy Management Strategy for a Parallel Hybrid Electric Truck Chan-Chiao Lin1 , Jun-Mo Kang2 , J efficiency. This paper presents a procedure for improving the energy management strategy for a parallel, control strategies based on engineering intuition frequently fail to achieve satisfactory overall system

  14. Incorporating Drivability Metrics into Optimal Energy Management Strategies for Hybrid Vehicles

    E-Print Network [OSTI]

    Grizzle, Jessy W.

    Incorporating Drivability Metrics into Optimal Energy Management Strategies for Hybrid Vehicles fuel economy performance is highly sensitive to the energy management strategy used to select among are characterized by multiple energy sources; the control strategy to select among these multiple energy sources

  15. Project Information Form Project Title Advanced Energy Management Strategy Development for Plug-in Hybrid

    E-Print Network [OSTI]

    California at Davis, University of

    Project Information Form Project Title Advanced Energy Management Strategy Development for Plug management strategy, which determines how energy flows in a hybrid powertrain should be managed in response for PHEVs using connected vehicle technology. Different energy management strategies will be developed

  16. Avoiding the Rush Hours: WiFi Energy Management via Traffic Isolation

    E-Print Network [OSTI]

    Shihada, Basem

    Avoiding the Rush Hours: WiFi Energy Management via Traffic Isolation Justin Manweiler Duke.rc@duke.edu ABSTRACT WiFi continues to be a prime source of energy consumption in mobile devices. This paper observes that, despite a rich body of research in WiFi energy management, there is room for improvement. Our key

  17. Energy Management and Task Scheduling of an Energy Harvesting, Structural Health Monitoring System

    E-Print Network [OSTI]

    Simunic, Tajana

    1 Energy Management and Task Scheduling of an Energy Harvesting, Structural Health Monitoring of a structure is referred to as Structural Health Monitoring (SHM). SHiMmer, a solar-powered wireless SHM system an energy management simulation that will prove to be important in SHiMmer's future. We test the three task

  18. A Communication-Based Appliance Scheduling Scheme for Consumer-Premise Energy Management Systems

    E-Print Network [OSTI]

    Snyder, Larry

    of electricity prices and distributed wind power uncertainty. We model the evolution of the protocol as a two is an energy management controller that incorporates prices and user preferences to providA Communication-Based Appliance Scheduling Scheme for Consumer-Premise Energy Management Systems

  19. An Energy Management Controller to Optimally Trade Off Fuel Economy and Drivability for Hybrid Vehicles

    E-Print Network [OSTI]

    Grizzle, Jessy W.

    An Energy Management Controller to Optimally Trade Off Fuel Economy and Drivability for Hybrid Abstract--Hybrid Vehicle fuel economy performance is highly sensitive to the energy management strategy used to regulate power flow among the various energy sources and sinks. Optimal non-causal solutions

  20. An Efficient Energy Management System for Android Phone Using Bayesian Networks

    E-Print Network [OSTI]

    Cho, Sung-Bae

    An Efficient Energy Management System for Android Phone Using Bayesian Networks Young-Seol Lee, proximity, light and orientation sensors for context-awareness. Energy-efficient battery management systems, it becomes an issue to develop the techniques for efficient energy management on a mobile phone [2, 3, 4

  1. Statistical Learning Controller for the energy management in a Fuel Cell Electric Vehicle

    E-Print Network [OSTI]

    Statistical Learning Controller for the energy management in a Fuel Cell Electric Vehicle M a high efficiency energy management control strategy for a hybrid fuel cell vehicle. The proposed the model of a real hybrid car, "Smile" developed by FAAM, using a stack of fuel cells as the primary power

  2. Wireless Sensors and Networks for Advanced Energy Management

    SciTech Connect (OSTI)

    Hardy, J.E.

    2005-05-06T23:59:59.000Z

    Numerous national studies and working groups have identified low-cost, very low-power wireless sensors and networks as a critical enabling technology for increasing energy efficiency, reducing waste, and optimizing processes. Research areas for developing such sensor and network platforms include microsensor arrays, ultra-low power electronics and signal conditioning, data/control transceivers, and robust wireless networks. A review of some of the research in the following areas will be discussed: (1) Low-cost, flexible multi-sensor array platforms (CO{sub 2}, NO{sub x}, CO, humidity, NH{sub 3}, O{sub 2}, occupancy, etc.) that enable energy and emission reductions in applications such as buildings and manufacturing; (2) Modeling investments (energy usage and savings to drive capital investment decisions) and estimated uptime improvements through pervasive gathering of equipment and process health data and its effects on energy; (3) Robust, self-configuring wireless sensor networks for energy management; and (4) Quality-of-service for secure and reliable data transmission from widely distributed sensors. Wireless communications is poised to support technical innovations in the industrial community, with widespread use of wireless sensors forecasted to improve manufacturing production and energy efficiency and reduce emissions. Progress being made in wireless system components, as described in this paper, is helping bring these projected improvements to reality.

  3. Energy Management: Best Practice Approach in a Carbon Constrained World 

    E-Print Network [OSTI]

    Spates, C. N.

    2008-01-01T23:59:59.000Z

    . A boiler control system, where appropriate, is developed to help monitor and control the boiler operation more efficiently. In the heavy metals and glass industries furnace and annealing operations are scrutinized to determine and install best...

  4. Energy Management Workbook for Local Governments : Workbook 1, Electrical Energy, 1981.

    SciTech Connect (OSTI)

    None

    1981-02-01T23:59:59.000Z

    Descriptions are presented for 20 major categories of energy actions providing background information needed for communities to implement energy management programs and explaining where financial and technical help may be available. Chapter 1 provides background on the energy problem, discusses Federal, state and local roles, and outlines the planning process. Chapter 2 is a list of 20 questions to help identify a range of potential actions that could become part of the energy management plan. Chapter 3 will help evaluate each of the twenty potential activities, and chapters 4 and 5 discuss implementing and monitoring the energy management plan. (MCW)

  5. IEEE TRANSACTIONS ON SMART GRID, VOL. 4, NO. 4, DECEMBER 2013 2139 Dynamic Energy Management for the Smart Grid

    E-Print Network [OSTI]

    Fu, Yong

    IEEE TRANSACTIONS ON SMART GRID, VOL. 4, NO. 4, DECEMBER 2013 2139 Dynamic Energy Management for the Smart Grid With Distributed Energy Resources Sergio Salinas, Student Member, IEEE, Ming Li, Student- lenges for energy management in the system. In this paper, we in- vestigate optimal energy management

  6. Characterizing and Exploiting Task-Load Variability and Correlation for Energy Management in Multi-Core Systems

    E-Print Network [OSTI]

    Tasiran, Serdar

    Characterizing and Exploiting Task-Load Variability and Correlation for Energy Management in Multi) Istanbul, Turkey Lausanne, Switzerland Abstract-- We present a hybrid energy management technique of the application. We use the stochastic models in formulating and solving the energy management prob- lem

  7. A Cyber Security Study of a SCADA Energy Management System: Stealthy Deception Attacks on the State Estimator

    E-Print Network [OSTI]

    Teixeira, André; Sandberg, Henrik; Johansson, Karl H

    2010-01-01T23:59:59.000Z

    The electrical power network is a critical infrastructure in today's society, so its safe and reliable operation is of major concern. State estimators are commonly used in power networks, for example, to detect faulty equipment and to optimally route power flows. The estimators are often located in control centers, to which large numbers of measurements are sent over unencrypted communication channels. Therefore cyber security for state estimators becomes an important issue. In this paper we analyze the cyber security of state estimators in supervisory control and data acquisition (SCADA) for energy management systems (EMS) operating the power network. Current EMS state estimation algorithms have bad data detection (BDD) schemes to detect outliers in the measurement data. Such schemes are based on high measurement redundancy. Although these methods may detect a set of basic cyber attacks, they may fail in the presence of an intelligent attacker. We explore the latter by considering scenarios where stealthy de...

  8. The use of energy management and control systems to monitor the energy performance of commercial buildings

    SciTech Connect (OSTI)

    Heinemeier, K E [Univ. of California, Berkeley, CA (United States). Dept. of Architecture

    1994-12-01T23:59:59.000Z

    Monitored data play a very important part in the implementation and evaluation of energy conservation technologies and programs. However, these data can be expensive to collect, so there is a need for lower-cost alternatives. In many situations, using the computerized Energy Management and Control Systems (EMCSs)--already installed in many buildings--to collect these commercial building performance data has advantages over more conventional methods. This method provides data without installing incremental hardware, and the large amounts of available operational data can be a very rich resource for understanding building performance. This dissertation addresses several of these issues. One specific objective is to describe a monitoring-project planning process that includes definition of objectives, constraints, resources and approaches for the monitoring. The choice of tools is an important part of this process. The dissertation goes on to demonstrate, through eight case studies, that EMCS monitoring is possible, and to identify and categorize the problems and issues that can be encountered. These issues lead to the creation, use, and testing of a set of methods for evaluation of EMCS monitoring, in the form of guidelines. Finally, EMCS monitoring is demonstrated and compared with conventional monitoring more methodically in a detailed case study.

  9. Occupancy-Based Energy Management in Buildings: Final Report to Sponsors

    SciTech Connect (OSTI)

    Sohn, Michael D.; Black, Douglas R.; Price, Phillip N.; Lin, Yiqing; Brahme, Rohini; Surana, Amit; Narayanan, Satish; Cerpa, Alberto; Ericson, Varick; Kamthe, Ankur

    2010-07-01T23:59:59.000Z

    The Lawrence Berkeley National Laboratory (LBNL), the University of California Merced (UCM), and the United Technologies Research Center (UTRC) conducted field studies and modeling analyses in the Classroom and Office Building (COB) and the Science and Engineering Building (S&E) at the University of California, Merced. In the first year, of a planned multiyear project, our goal was to study the feasibility and efficacy of occupancy-based energy management. The first-year research goals were twofold. The first was to explore the likely energy savings if we know the number and location of building occupants in a typical commercial building. The second was to model and estimate people movement in a building. Our findings suggest that a 10-14percent reduction in HVAC energy consumption is possible over typical HVAC operating conditions when we know occupancy throughout the building. With the conclusion of the first-year tasks, we plan to review these results further before this group pursues follow-on funding.

  10. Sustainable approach to achieving energy efficiency in manufacturing operations

    E-Print Network [OSTI]

    McKenney, Kurtis G. (Kurtis Gifford), 1979-

    2012-01-01T23:59:59.000Z

    Energy management in industrial facilities is becoming increasingly popular as firms attempt to become more environmentally responsible and reduce cost by improving operational efficiency. Raytheon is a leader in their ...

  11. System design and dynamic signature identification for intelligent energy management in residential buildings.

    E-Print Network [OSTI]

    Jang, Jaehwi

    2008-01-01T23:59:59.000Z

    Drewer and D. Gann, Smart buildings, Journal of Facilities ,smart energy management system specically for residential buildings.buildings is rooted in relative eectiveness per system by a smart

  12. Why Energy Audits Aren't Enough: An Energy Management System is Required 

    E-Print Network [OSTI]

    Haft, A. J.

    1980-01-01T23:59:59.000Z

    An evaluation of the energy systems in a plant can be accomplished by different techniques which require different levels of effort. Three alternatives are described: Rational Analysis, Energy Audits and Energy Management by Utility Systems Metering...

  13. Energy Management: A Corporate Objective in the Five-Year Business Plan 

    E-Print Network [OSTI]

    Mulhern, T. A.

    1982-01-01T23:59:59.000Z

    This paper presents the Energy Management Program developed by the Western Electric Company. The program includes managerial accountabilities; administrative and technical activities; and a most recently implemented comprehensive five-year energy...

  14. Continuous Controls: Lighting Energy Management for Retrofit and New Construction Projects

    E-Print Network [OSTI]

    Schuett, R.

    1985-01-01T23:59:59.000Z

    The rising interest of specifiers and end-users in Lighting Energy Management (LEM) control equipment has led to an increased need for further education in the selection, capabilities and applications of such equipment. This paper addresses...

  15. Research on Commercial Patterns of China Existing Building Energy Retrofit Based on Energy Management Contract 

    E-Print Network [OSTI]

    Han, Z.; Liu, C.; Sun, J.

    2006-01-01T23:59:59.000Z

    Existing building energy retrofit is one of the keys of building energy efficiency in China. According to experience in developed countries, implementation of energy management contract (EMC) is crucial to promote existing building energy retrofit...

  16. Why Energy Audits Aren't Enough: An Energy Management System is Required

    E-Print Network [OSTI]

    Haft, A. J.

    1980-01-01T23:59:59.000Z

    An evaluation of the energy systems in a plant can be accomplished by different techniques which require different levels of effort. Three alternatives are described: Rational Analysis, Energy Audits and Energy Management by Utility Systems Metering...

  17. An energy management IC for bio-implants using ultracapacitors for energy storage

    E-Print Network [OSTI]

    Sanchez, William R.

    We present the first known energy management IC to allow low-power systems, such as biomedical implants, to optimally use ultracapacitors instead of batteries as their chief energy storage elements. The IC, fabricated in ...

  18. Energy Management and RD & D Activities for Energy Conservation in TEPCO

    E-Print Network [OSTI]

    Ohmori, M.; Yoshihama, K.

    1981-01-01T23:59:59.000Z

    The followings are mentioned on the experiences and results through performance of energy management and RD & D activities for energy conservation in TEPCO. - Public Relations and Energy Audit Activities. - RD & D Activities (1) Demand...

  19. Energy Management: A Corporate Objective in the Five-Year Business Plan

    E-Print Network [OSTI]

    Mulhern, T. A.

    1982-01-01T23:59:59.000Z

    This paper presents the Energy Management Program developed by the Western Electric Company. The program includes managerial accountabilities; administrative and technical activities; and a most recently implemented comprehensive five-year energy...

  20. Research on Commercial Patterns of China Existing Building Energy Retrofit Based on Energy Management Contract

    E-Print Network [OSTI]

    Han, Z.; Liu, C.; Sun, J.

    2006-01-01T23:59:59.000Z

    Existing building energy retrofit is one of the keys of building energy efficiency in China. According to experience in developed countries, implementation of energy management contract (EMC) is crucial to promote existing building energy retrofit...

  1. Forecasting and Capturing Emission Reductions Using Industrial Energy Management and Reporting Systems 

    E-Print Network [OSTI]

    Robinson, J.

    2010-01-01T23:59:59.000Z

    The Mandatory 2010 Green House Gas (GHG) Reporting Regulations and pending climate change legislation has increased interest in Energy Management and Reporting Systems (EMRS) as a means of both reducing and reporting GHG ...

  2. Forecasting and Capturing Emission Reductions Using Industrial Energy Management and Reporting Systems

    E-Print Network [OSTI]

    Robinson, J.

    2010-01-01T23:59:59.000Z

    The Mandatory 2010 Green House Gas (GHG) Reporting Regulations and pending climate change legislation has increased interest in Energy Management and Reporting Systems (EMRS) as a means of both reducing and reporting GHG emissions. This paper...

  3. Rule Based Energy Management and Reporting System (EMRS) Applied to a Large Utility Power Station Complex

    E-Print Network [OSTI]

    Bamber, D.; Childress, R.; Robinson, J.

    2004-01-01T23:59:59.000Z

    Deregulation of electricity and rising fuel costs are causing renewed interest in Energy Management Systems (EMS) to service both the utility and private sectors. This paper details a case study of the successful integration of a new class of rule...

  4. Rule-Based Energy Management System Applied to Large Industrial Facilities

    E-Print Network [OSTI]

    Gauthier, M.; Childress, R. L.

    Deregulation of electricity and rising fuel costs are causing renewed interest in Energy Management Systems (EMS). This paper details the results of integrating a rule-based EMS controller at a Pulp and Paper Mill and additional findings from...

  5. A Unified and Integrated Energy Management System for HVAC Spaces and Power House 

    E-Print Network [OSTI]

    Kaya, A.; Debban, G. D.

    1988-01-01T23:59:59.000Z

    This paper describes a totally integrated energy management system throughout the plant and facilities. The equipment involves: the power plant (boilers, cogeneration turbines, chillers); HVAC of buildings; air handling and other distribution...

  6. Report on Audit of Department of Energy Management and Operating Contractor Available Fees, IG-0390

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn April 23, 2014, an OHASeptemberAssessments | Department ofSouthernof theServiceJune 6,8,

  7. Extension of DOE O 430.2, In-House Energy Management

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2000-12-13T23:59:59.000Z

    This Notice extends DOE O 430.2, IN-HOUSE ENERGY MANAGEMENT, dated 6-13-96 until 6-13-01, unless sooner rescinded. The Order is being revised to implement Executive Order 13123, Greening of the Government Through Efficient Energy Management, and a Secretarial Memorandum, Pollution Prevention and Energy Efficiency Leadership Goals, and to include the acquisition, planning and management of utilities. Does not cancel other directives.

  8. Creating Reliable Data and Reporting to Support Strategic Energy Management at Corning Incorporated

    E-Print Network [OSTI]

    Garforth, P.

    2014-01-01T23:59:59.000Z

    Creating Reliable Data & Reporting to Support Strategic Energy Management at Corning Incorporated Industrial Energy Technology Conference May 20th, 2014 New Orleans, Louisiana Peter Garforth Garforth International llc Energy Managers’ Workshop ESL... relevant energy data to support Corporate performance targets ESL-IE-14-05-29 Proceedings of the Thrity-Sixth Industrial Energy Technology Conference New Orleans, LA. May 20-23, 2014 Performance Reporting Totals – Usage, Cost, GHG-Emissions Corp Division...

  9. Plant Wide Energy Management and Reporting Systems Provide Sustainable Results

    E-Print Network [OSTI]

    Robinson, J. E.

    2007-01-01T23:59:59.000Z

    different steam production rates and operating conditions. Figure 3 - FFE Performance Calculation Basis TARGET PROFILE - PB#4 and PB#5 REMOVED Previous Advanced Control System - 1/1 to 12/31/2004 - 7,382 Hours 2004 Power Boiler PB#1, PB#2, and PB#3... of O p er at i o n Best 75th Ptile Poor Hours of Operation TARGET PROFILE - PB4 and PB5 Removed Previous Advanced Control Operational 1/1 to 12/31/2004-7,382 Hours Power Boiler PB#1, PB#2, and PB#3 - Excluding PB#4 and PB#5 Fossil Fuel Effectiveness...

  10. Energy Management Program at Atlanta Postal Service Distribution Center

    E-Print Network [OSTI]

    Brown, M.; Ansari, A.

    2001-01-01T23:59:59.000Z

    The US Postal Service operates more than 38,000 post offices across the country and spends $350 million annually on utilities (1). Driven by President Clinton's 1999 Executive Order that mandates a 35 percent reduction in federal energy consumption...

  11. Energy Management in a Multi-Industry Organization

    E-Print Network [OSTI]

    Lawrence, J.

    1981-01-01T23:59:59.000Z

    Tenneco operates in seven of the nation's ten most energy intensive industries: Petroleum Refining, Chemicals Manufacturing, Pulp and Paper, Transportation Equipment, Primary Metals, Food Processing, and Machinery. This diversification...

  12. 1 A Centralized Optimal Energy Management System for Microgrids

    E-Print Network [OSTI]

    Daniel E. Olivares; Claudio A. Cañizares; Mehrdad Kazerani; Senior Member

    Abstract — The issue of controlled and reliable integration of distributed energy resources into microgrids and large power grids has recently gained considerable attention. The microgrid concept, which basically corresponds to the coordinated operation of a cluster of loads, distributed generators

  13. Performance Directed Energy Management for Main Memory and Disks

    E-Print Network [OSTI]

    Zhou, Yuanyuan

    grant, a gift from Intel Corp., and the National Science Foundation under Grant No. CCR-0096126, EIA in the design of computing systems. For battery-operated mobile devices, energy consumption directly affects]. The storage hierarchy, which includes memory and disks, is a major energy consumer in computer systems

  14. What is Energy Management and why is it important?

    E-Print Network [OSTI]

    Little, Tony

    currently affecting the sector. The companies involved include Wood Mackenzie, the leading energy research and consultancy organisation to manufacturing companies, energy suppliers and even the UK Nuclear Decommissioning about the operation of solar PV systems and biomass boilers. We learned, not only about different types

  15. Incremental Implementation of Energy Management at Industrial Facilities 

    E-Print Network [OSTI]

    Brown, M.; Key, G.

    2005-01-01T23:59:59.000Z

    corporate decision to reduce the environmental impact of operations. Although reduction of environmental impacts is an internal decision, it is often dictated by the organizational desire to appease external environmental pressures. While the desire... Coverings (C&A), Dalton and Yamaha Motor Company, Newnan, Georgia. While cost control is important at each of these locations, the deciding factor for MSE 2000 implementation at both locations was reduced environmental impact. These companies...

  16. Comprehensive Energy Management and CC® at DFW Airport

    E-Print Network [OSTI]

    Kramer, L.

    2011-01-01T23:59:59.000Z

    - 174 gates ? 685,000 operations annually ? 60 million passengers annually ? $26.5 MM energy budget ? ~200 electric accounts ? 20 natural gas accounts 7.7 miles 8 .1 mi le s Continuous Commissioning? of DFW International Airport, ICEBO... October 20, 2011 3 Continuous Commissioning? - Consolidated Rent-A-Car Center ? Opened in 2000, First CC in 2004 and a follow up in 2010 ? Excessive outside air ? Duct static pressure too high ? Economizer cycle was not optimized ? Space...

  17. Energy Management in a Large Refining-Petrochemical Complex

    E-Print Network [OSTI]

    Jones, K. C.

    1981-01-01T23:59:59.000Z

    if it has no alternate disposition) and the stream's value as fuel to the boiler. In this latter calculation you need to consider not only the value of the di sp 1aced fuel but also any detri menta 1 effects that wi 11 be caused by burni ng the waste... the plan and the better trained the operating personne1, the more one can decrease surpl\\.1s and, thereby, improve efficiency witholit hurting reliability. Through the Utilities Distribution Department and the team approach, DPMC has achieved a...

  18. FEMP Update: Federal Energy Management activities, July 1985

    SciTech Connect (OSTI)

    Not Available

    1985-01-01T23:59:59.000Z

    Since early 1984, FEMP has examined a number of innovative techniques for financing energy efficiency improvements in Federal facilities. Having identified a number of legal and procurement barriers to shared savings contracting by Federal agencies, FEMP set out to identify and explore possible solutions. Currently, it has narrowed in on three specific options which represent potentially viable approaches to Federal energy financing: (1) removing regulatory and institutional barriers to energy services contracts with the private sector; (2) implementing energy services agreements at Government Owned Contractor Operated (GOCO) facilities; and (3) establishing a government financial corporation to fund agency energy conservation investments. These possible solutions are discussed in the report. The third possibility is regarded as unlikely.

  19. Tripol condensate polishing - operational experience

    SciTech Connect (OSTI)

    Swainsbury, D. [Mission Energy Management Australia, Victoria (Australia)

    1995-01-01T23:59:59.000Z

    This paper gives a brief outline of the Mission Energy Management Australia Company who operate and maintain the Loy Yang B Power Station in the Latrobe Valley, Victoria, Australia. Details of the plant configuration, the water/steam circuit and cycle chemistry are discussed. The arrangement of the TRIPOL Condensate Polishing Plant and it`s operational modes are examined. Results of the first twelve months operation of the TRIPOL plant are detailed. Levels of crud removal during early commissioning phases employing the pre-filter are presented. Typical parameters achieved during a simulated condenser leak and an operational run beyond the ammonia break point are also documented.

  20. Energy Management for an Onboard Storage System Based on Multi-Objective Optimization

    E-Print Network [OSTI]

    Paderborn, Universität

    Energy Management for an Onboard Storage System Based on Multi-Objective Optimization Tobias Knoke an onboard energy storage, the overhead line peak power and energy consumption can be reduced. The storage. This can be achieved by using an onboard energy storage, which recuperates the power during the braking

  1. Energy Management for Real-Time Embedded Applications with Compiler Support

    E-Print Network [OSTI]

    Melhem, Rami

    Energy Management for Real-Time Embedded Applications with Compiler Support Nevine Abou device energy has become one of the most impor- tant challenges to embedded systems designers. Processors supported by the Defense Advanced Research Projects Agency through Power Aware Real- Time Systems (PARTS

  2. OPTIMIZATION WITH ENERGY MANAGEMENT OF PV BATTERY STAND-ALONE SYSTEMS OVER THE ENTIRE LIFE CYCLE

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    of both the installed PV power and storage capacity (lead-acid battery technology for purposes). Keywords: Battery storage and control, Lifetime simulation, PV system. 1. INTRODUCTION Given the sizableOPTIMIZATION WITH ENERGY MANAGEMENT OF PV BATTERY STAND-ALONE SYSTEMS OVER THE ENTIRE LIFE CYCLE

  3. The Case for Efficient Renewable Energy Management in Smart Binghamton University

    E-Print Network [OSTI]

    Shenoy, Prashant

    they produce back to the utility company--to offset their cost relative to grid energy. DG is a much lessThe Case for Efficient Renewable Energy Management in Smart Homes Ting Zhu Binghamton University (DG) uses many small on-site en- ergy sources deployed at individual buildings to generate electricity

  4. Efficiency improvement of a ground coupled heat pump system from energy management

    E-Print Network [OSTI]

    Fernández de Córdoba, Pedro

    Efficiency improvement of a ground coupled heat pump system from energy management N. Pardo a,*, Á coupled heat pump Energy efficiency Numerical simulation a b s t r a c t The installed capacity of an air to improve the efficiency of a ground coupled heat pump air conditioning system by adapting its produced

  5. A Compilation Framework for Power and Energy Management on Mobile Computers

    E-Print Network [OSTI]

    Kremer, Ulrich

    . Initial experiments show that energy consumption can be reduced signifi­ cantly, in some cases up to oneA Compilation Framework for Power and Energy Management on Mobile Computers Ulrich Kremer #3; Jamey in mobile environments. Image processing can be used in autonomous robot navigation, target acquisition

  6. Efficient Energy Management and Data Recovery in Sensor Networks using Latent Variables Based Tensor

    E-Print Network [OSTI]

    Simunic, Tajana

    Efficient Energy Management and Data Recovery in Sensor Networks using Latent Variables Based factor in a successful sensor network deployment is finding a good balance between maximizing the number of measurements taken (to maintain a good sampling rate) and minimizing the overall energy consumption (to extend

  7. Extension of DOE O 430.2, In-House Energy Management

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2000-06-13T23:59:59.000Z

    The Order is in the process of being revised to implement E.O. 13123, Greening of the Government Through Efficient Energy Management, and a Secretarial Memorandum, Pollution Prevention and Energy Efficiency Leadership Goals. The revision will also include the acquisition, planning and management of utilities. Does not cancel other directives.

  8. Comfort-Aware Home Energy Management Under Market-Based Demand-Response

    E-Print Network [OSTI]

    Boutaba, Raouf

    pricing and consumption data in South Korea. Index Terms--smart grid, demand-response, energy management I-based pricing. In peak capping, each home is allocated an energy quota. In market-based pricing, the price-term viable way of regulating energy consumptions. We work with day-ahead market pricing in this paper

  9. Balance of Power: Energy Management for Server Clusters Je rey S. Chase

    E-Print Network [OSTI]

    terawatt-hours TWh of electricity in the US in 1999, more than the Internet switching infrastructure itself, the Internet service infrastructure contin- ues to grow rapidly, adding to strains on the global power gridBalance of Power: Energy Management for Server Clusters Je rey S. Chase Department of Computer

  10. Self-Optimization Energy Management Considering Stochastic Influences for a Hybrid

    E-Print Network [OSTI]

    Paderborn, Universität

    Self-Optimization Energy Management Considering Stochastic Influences for a Hybrid Energy Storage--Electric and hybrid-electric vehicles place high de- mands for peak power, energy content and efficiency on the en management, hybrid energy storage system, self-optimization I. INTRODUCTION TODAY'S electric and hybrid

  11. Performance Comparison of Hybrid Vehicle Energy Management Controllers on Real-World Drive Cycle Data

    E-Print Network [OSTI]

    Grizzle, Jessy W.

    Performance Comparison of Hybrid Vehicle Energy Management Controllers on Real-World Drive Cycle. Hybrid vehicles are characterized by multiple energy sources; the strategy to control the energy flow Data Daniel F. Opila, Xiaoyong Wang, Ryan McGee, Jeffrey A. Cook, and J.W. Grizzle Abstract-- Hybrid

  12. Energy Management System for an Hybrid Electric Vehicle, Using Ultracapacitors and Neural Networks

    E-Print Network [OSTI]

    Catholic University of Chile (Universidad Católica de Chile)

    Energy Management System for an Hybrid Electric Vehicle, Using Ultracapacitors and Neural Networks and specific energy contained in most electric batteries compared to that of gasoline, is resolved in hybrid to accept energy from regenerative braking. For this reason, hybrid systems use an auxiliary energy system

  13. Incorporating Drivability Metrics into Optimal Energy Management Strategies for Hybrid Vehicles Part 1: Model, Methods, and

    E-Print Network [OSTI]

    Grizzle, Jessy W.

    Incorporating Drivability Metrics into Optimal Energy Management Strategies for Hybrid Vehicles-parallel configuration considered here. Hybrid vehicles are characterized by multiple energy sources; the strategy Gillespie, Jeffrey A. Cook, and J.W. Grizzle Abstract--Hybrid Vehicle fuel economy performance is highly

  14. Department of Energy and Mineral Engineering Spring 2013 Solar Innovations, Inc. Energy Management Program

    E-Print Network [OSTI]

    Demirel, Melik C.

    Management Program Overview A team of six energy engineering students was assigned the task of developing an energy management program in order to reduce the client's energy use. The team had 14 weeks (1 semesterPENNSTATE Department of Energy and Mineral Engineering Spring 2013 Solar Innovations, Inc. Energy

  15. Using a Practical Approach to Energy Management to Get it Done

    E-Print Network [OSTI]

    Nicol, J.; Dantoin, T.

    2008-01-01T23:59:59.000Z

    The Wisconsin Focus on Energy program saw a need in 2002 to develop a template for energy management so that companies could easily implement a systematic and continual improvement approach to manage their energy. To meet this need the Focus program...

  16. A Supply-Demand Model Based Scalable Energy Management System for Improved Energy

    E-Print Network [OSTI]

    Bhunia, Swarup

    energy generation and consumption parameters. The system uses economics inspired supply-demand modelA Supply-Demand Model Based Scalable Energy Management System for Improved Energy Utilization Western Reserve University, *Cleveland State University, +Rockwell Automation, Cleveland, OR, USA Email

  17. Power and Energy Management for Server Systems Ricardo Bianchini + and Ram Rajamony #

    E-Print Network [OSTI]

    Bianchini, Ricardo

    , of servers and supporting cooling infrastructures. Research on power and energy management for servers can requests coming from remote clients or other servers. Common examples are Web and application servers consumption have become key concerns in data centers. The peak power consumption dictates the required cooling

  18. ISO launches a project committee to develop an International Standard for energy management

    Broader source: Energy.gov [DOE]

    American National Standards Institute (ANSI) approved the formation of a U.S. Technical Advisory Group (US TAG) to the ISO Project Committee 242. The TAG is a mechanism for identifying issues and developing national consensus regarding energy management. Read this announcement for more details about the group's charge and how to participate.

  19. DEMAND SIDE ENERGY MANAGEMENT AND CONSERVATION PROGRAM Measurement and Verification Program

    E-Print Network [OSTI]

    Hofmann, Hans A.

    DEMAND SIDE ENERGY MANAGEMENT AND CONSERVATION PROGRAM Measurement and Verification Program 4 Works Association Research Foundation (AwwaRF) and building demographics for savings calculations 4-retrofit; calculate savings in room by room spreadsheet 5. Pre-retrofit (Process water audit) ­ Walk buildings

  20. PROACTIVE ENERGY MANAGEMENT FOR NEXT-GENERATION BUILDING Victor M. Zavala1, Jianhui Wang2, Sven Leyffer1

    E-Print Network [OSTI]

    Anitescu, Mihai

    PROACTIVE ENERGY MANAGEMENT FOR NEXT-GENERATION BUILDING SYSTEMS Victor M. Zavala1, Jianhui Wang2 S Cass Ave, Argonne, IL 60439 ABSTRACT We present a proactive energy management framework that integrates predictive dynamic building models and day-ahead forecasts of disturbances affecting efficiency and costs

  1. Cascadia Supercycles: Evidence of Clustering and Holocene History of Energy Management from the Long Cascadia Paleoseismic Record

    E-Print Network [OSTI]

    Goldfinger, Chris

    Cascadia Supercycles: Evidence of Clustering and Holocene History of Energy Management from attempt to address the issue of energy management over multiple earthquake cycles through the temporal earthquakes is assumed to increase elastic strain energy in proportion to interevent time. We propose

  2. Energy Management in IaaS Clouds: A Holistic Eugen Feller, Cyril Rohr, David Margery, Christine Morin

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Energy Management in IaaS Clouds: A Holistic Approach Eugen Feller, Cyril Rohr, David Margery and experimentally evaluated in a realistic environment. In this paper we present the energy management algorithms and mechanisms of a novel holistic energy-aware VM manage- ment framework for private clouds called Snooze. We

  3. An ANFIS Based Sensor Network for a Residential Energy Management System D. Senthilkumar, S. Kumar, Y. Ozturk and G. Lee

    E-Print Network [OSTI]

    Kumar, Sunil

    An ANFIS Based Sensor Network for a Residential Energy Management System D. Senthilkumar, S. Kumar management system project, an Integrated and Cognitive Home Energy Management System for Demand Response (DR management system which addresses demand response with efficient energy consumption. 1. Introduction State

  4. Process management principles for increasing the energy efficiency of manufacturing operations

    E-Print Network [OSTI]

    Espindle, L. P. (Leo P.)

    2011-01-01T23:59:59.000Z

    Energy usage is a significant operating cost for manufacturing facilities in the United States, and interest in energy management has been rising of late, 2, 3]. One approach, recommended by the Environmental Protection ...

  5. Intelligent Building Energy Information and Control Systems for Low-Energy Operations and Optimal Demand Response

    E-Print Network [OSTI]

    Piette, Mary Ann

    2014-01-01T23:59:59.000Z

    Systems for  Energy Management and Demand Response in 7.  Linking energy efficiency and demand response.   In for Low-Energy Operations and Optimal Demand Response Mary

  6. A Methodology for Optimizing Boiler Operating Strategy

    E-Print Network [OSTI]

    Jones, K. C.

    1983-01-01T23:59:59.000Z

    Among the many ways by which an energy manager can conserve energy is the establishment of a strategy for operation of fired boilers. In particular, he can effect total fuel consumption by his decision on how much on-line boiler surplus is required...

  7. 2001 ''You Have the Power'' campaign [Federal Energy Management Program]. Final technical report

    SciTech Connect (OSTI)

    NONE

    2002-01-01T23:59:59.000Z

    The Tasks of 2001 ''You Have the Power'' campaign by the Federal Energy Management Program (FEMP) are: Task 1--Interagency Planning Meetings; Task 2--Ear Day Event; Task 3--Earth Day and Energy Awareness Month Activities; Task 4--Regional Target; Task 5--Outreach Tools and Campaign Products; Task 6--Private Sector Participation; Task 7--''You Have the Power'' on the FEMP Web Site; and Task 8--Effective Communications.

  8. Energy Management of Steam Distribution Systems Through Energy Audits and Computerized Reporting Programs

    E-Print Network [OSTI]

    Rivers, N.; Mandzuk, N.

    ENERGY KANAGEKBNT OF STEAM DISTRIBUTION SYSTEMS THROUGH BNKRGY AUDITS AND COItPlTl'ERIZED REPORTING PROGRAtIS NORMAN J. RIVERS and HARTIN MANDZUK Armstrong Machine Works, Inc. Three Rivers, Michigan ABSTRACT This presentation will highlight... the economic losses associated with steam distribution systems and how to establish good energy management programs to reduce energy cost by 15 to 25 percent. Recognizing energy losses in steam systems involves I 1. Steam lost through defective valves...

  9. Energy Management System Lowers U.S. Navy Energy Costs Through PV System Interconnection (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-04-01T23:59:59.000Z

    To meet the U.S. Navy's energy goals, the National Renewable Energy Laboratory (NREL) and the Naval Facilities Engineering Command (NAVFAC) spent two years collaborating on demonstrations that tested market-ready energy efficiency measures, renewable energy generation, and energy systems integration. One such technology - an energy management system - was identified as a promising method for reducing energy use and costs, and can contribute to increasing energy security.

  10. Federal Energy Management Program (FEMP) Technical Assistance Request Portal User Guide

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport in RepresentativeDepartmentEnergyEnergy Management Program Technical

  11. Energy Management

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8, 2000Consumption Survey (CBECS) Data 210 Available in4LiBNEnergy

  12. Next-generation building energy management systems and implications for electricity markets.

    SciTech Connect (OSTI)

    Zavala, V. M.; Thomas, C.; Zimmerman, M.; Ott, A. (Mathematics and Computer Science); (Citizens Utility Board); (BuildingIQ Pty Ltd, Australia); (PJM Interconnection LLC)

    2011-08-11T23:59:59.000Z

    The U.S. national electric grid is facing significant changes due to aggressive federal and state targets to decrease emissions while improving grid efficiency and reliability. Additional challenges include supply/demand imbalances, transmission constraints, and aging infrastructure. A significant number of technologies are emerging under this environment including renewable generation, distributed storage, and energy management systems. In this paper, we claim that predictive energy management systems can play a significant role in achieving federal and state targets. These systems can merge sensor data and predictive statistical models, thereby allowing for a more proactive modulation of building energy usage as external weather and market signals change. A key observation is that these predictive capabilities, coupled with the fast responsiveness of air handling units and storage devices, can enable participation in several markets such as the day-ahead and real-time pricing markets, demand and reserves markets, and ancillary services markets. Participation in these markets has implications for both market prices and reliability and can help balance the integration of intermittent renewable resources. In addition, these emerging predictive energy management systems are inexpensive and easy to deploy, allowing for broad building participation in utility centric programs.

  13. Smart Energy Management and Control for Fuel Cell Based Micro-Grid Connected Neighborhoods

    SciTech Connect (OSTI)

    Dr. Mohammad S. Alam

    2006-03-15T23:59:59.000Z

    Fuel cell power generation promises to be an efficient, pollution-free, reliable power source in both large scale and small scale, remote applications. DOE formed the Solid State Energy Conversion Alliance with the intention of breaking one of the last barriers remaining for cost effective fuel cell power generation. The Alliance’s goal is to produce a core solid-state fuel cell module at a cost of no more than $400 per kilowatt and ready for commercial application by 2010. With their inherently high, 60-70% conversion efficiencies, significantly reduced carbon dioxide emissions, and negligible emissions of other pollutants, fuel cells will be the obvious choice for a broad variety of commercial and residential applications when their cost effectiveness is improved. In a research program funded by the Department of Energy, the research team has been investigating smart fuel cell-operated residential micro-grid communities. This research has focused on using smart control systems in conjunction with fuel cell power plants, with the goal to reduce energy consumption, reduce demand peaks and still meet the energy requirements of any household in a micro-grid community environment. In Phases I and II, a SEMaC was developed and extended to a micro-grid community. In addition, an optimal configuration was determined for a single fuel cell power plant supplying power to a ten-home micro-grid community. In Phase III, the plan is to expand this work to fuel cell based micro-grid connected neighborhoods (mini-grid). The economic implications of hydrogen cogeneration will be investigated. These efforts are consistent with DOE’s mission to decentralize domestic electric power generation and to accelerate the onset of the hydrogen economy. A major challenge facing the routine implementation and use of a fuel cell based mini-grid is the varying electrical demand of the individual micro-grids, and, therefore, analyzing these issues is vital. Efforts are needed to determine the most appropriate means of implementing micro-grids and the costs and processes involved with their extended operation. With the development and availability of fuel cell based stand-alone power plants, an electrical mini-grid, encompassing several connected residential neighborhoods, has become a viable concept. A primary objective of this project is to define the parameters of an economically efficient fuel cell based mini-grid. Since pure hydrogen is not economically available in sufficient quantities at the present time, the use of reforming technology to produce and store excess hydrogen will also be investigated. From a broader perspective, the factors that bear upon the feasibility of fuel cell based micro-grid connected neighborhoods are similar to those pertaining to the electrification of a small town with a localized power generating station containing several conventional generating units. In the conventional case, the town or locality would also be connected to the larger grid system of the utility company. Therefore, in the case of the fuel cell based micro-grid connected neighborhoods, this option should also be available. The objectives of this research project are: To demonstrate that smart energy management of a fuel cell based micro-grid connected neighborhood can be efficient and cost-effective;To define the most economical micro-grid configuration; and, To determine how residential micro-grid connected fuel cell(s) can contribute to America's hydrogen energy future.

  14. by the ratio of biogas production to organic matter input : 0.20 to 0.3 M3/kg organic When considering the period of steady operation, i.e. without technical problems such

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    by the ratio of biogas production to organic matter input : 0.20 to 0.3 M3/kg organic matter. When of digestible amino acids. The definition of availability is recalled and the methods used to estimate it briefly examined ; that based on measurements of the apparent digestibility being apparently the most

  15. US Air Force Facility Energy Management Program - How Industry Can Help the Air Force Meet Its Objectives

    E-Print Network [OSTI]

    Holden, P. C.; Kroop, R. H.

    1983-01-01T23:59:59.000Z

    This paper describes the Air Force's facility energy management program including how industry can help the Air Force meet its facility energy objectives. Background information on energy use and energy conservation efforts are presented to give...

  16. Improving Unit Operations-Test Station Performance

    E-Print Network [OSTI]

    Filak, J. J. Jr.

    IMPROVING UNIT OPERATIONS - TEST STATION PERFORMANCE JosqIb 1. Filak. Jr, ? Corporate Energy Manager. Park.er?Hannafin COfpontioo- Cleveland. Oh ABSTRACT: This program's basic concept deals with the possibilities for reducing energy efficiency... requirements, control operation test performance functions more successfully, and retain peak load surges from reaching higher utility rate expense levels. 142 ESL-IE-95-04-23 Proceedings from the Seventeenth Industrial Energy Technology Conference...

  17. Use of EMCS Recorded Data to Identify Potential Savings Due to Improved HVAC Operations & Maintenance (O&M)

    E-Print Network [OSTI]

    Liu, M.; Zhu, Y.; Claridge, D. E.

    1996-01-01T23:59:59.000Z

    In most chiller and boiler central plants, the energy management and control systems (EMCS) monitor and record key operation parameters and energy production continuously. A method was developed to identify potential O&M savings by using the EMCS...

  18. Thinking Globally: How ISO 50001 - Energy Management can make industrial energy efficiency standard practice

    SciTech Connect (OSTI)

    McKane, Aimee; Desai, Deann; Matteini, Marco; Meffert, William; Williams, Robert; Risser, Roland

    2009-08-01T23:59:59.000Z

    Industry utilizes very complex systems, consisting of equipment and their human interface, which are organized to meet the production needs of the business. Effective and sustainable energy efficiency programs in an industrial setting require a systems approach to optimize the integrated whole while meeting primary business requirements. Companies that treat energy as a manageable resource and integrate their energy program into their management practices have an organizational context to continually seek opportunities for optimizing their energy use. The purpose of an energy management system standard is to provide guidance for industrial and commercial facilities to integrate energy efficiency into their management practices, including fine-tuning production processes and improving the energy efficiency of industrial systems. The International Organization for Standardization (ISO) has identified energy management as one of its top five priorities for standards development. The new ISO 50001 will establish an international framework for industrial, commercial, or institutional facilities, or entire companies, to manage their energy, including procurement and use. This standard is expected to achieve major, long-term increases in energy efficiency (20percent or more) in industrial, commercial, and institutional facilities and to reduce greenhouse gas (GHG) emissions worldwide.This paper describes the impetus for the international standard, its purpose, scope and significance, and development progress to date. A comparative overview of existing energy management standards is provided, as well as a discussion of capacity-building needs for skilled individuals to assist organizations in adopting the standard. Finally, opportunities and challenges are presented for implementing ISO 50001 in emerging economies and developing countries.

  19. The FEMP Awards Program: Fostering Institutional Change and Energy Management Excellence

    SciTech Connect (OSTI)

    McDermott, Christa; Malone, Elizabeth L.

    2014-05-20T23:59:59.000Z

    This report assesses the use of institutional change principles and the institutional impact of award-winning projects through interviews with 22 Department of Energy Federal Energy Management Program (DOE FEMP) award winners. Award winners identified institutional facilitators and barriers in their projects and programs as well as factors in their implementation processes, thus providing information that can guide other efforts. We found that award winners do use strategies based on eight principles of institutional change, most frequently in terms of making changes to infrastructure, engaging leadership, and capitalizing on multiple motivations for making an energy efficiency improvement. The principles drawn on the least often were commitment and social empowerment. Award winners also faced five major types of obstacles that were institutional in nature: lack of resources, constraints of rules, psychological barriers, lack of information, and communication problems. We also used the seven categories of Energy Management Excellence (EME) as a lens to interpret the interview data and assess whether these categories relate to established institutional change principles. We found that the eight principles reflect strategies that have been found to be useful in improving energy efficiency in organizations, whereas the EME categories capture more of a blend of social contextual factors and strategies. The EME categories fill in some of the social context gaps that facilitate institutional change and energy management excellence, for example, personal persistence, a culture that supports creativity and innovation, regular engagement with tenants, contractors, and staff at all levels. Taking together the use of principles, EME criteria, and obstacles faced by interviewees, we make recommendations for how FEMP can better foster institutional change in federal agencies.

  20. Case Study: Continuous Commissioning and Energy Management at Alamo Colleges, San Antonio, TX

    E-Print Network [OSTI]

    Martinez, J. T.

    2014-01-01T23:59:59.000Z

    : Superintendents Facilities Foreman HVAC Foreman Energy Systems Laboratory Joseph Martinez Norma L. Rangel, PhD Ian Nelson, PhD Ahmet Ugursal, PhD Agnes Almeida (MSc student) Data Analysis: Juan-Carlos Baltazar, PhD Alaina Jones (PhD student) Energy Management...Workshop on the Continuous Commissioning® Process Joseph T. Martinez, PCC Carlos Yagua, PE Hiroko Masuda, Juan-Carlos Baltazar, PhD, PE Ahmet Ugursal, PhD Clean Air Through Energy Efficiency (CATEE) Conference, Dallas, Texas. November 18, 2014...

  1. Electric Energy Management in the Smart Home: Perspectives on Enabling Technologies and Consumer Behavior: Preprint

    SciTech Connect (OSTI)

    Zipperer, A.; Aloise-Young, P. A.; Suryanarayanan, S.; Roche, R.; Earle, L.; Christensen, D.; Bauleo, P.; Zimmerle. D.

    2013-08-01T23:59:59.000Z

    Smart homes hold the potential for increasing energy efficiency, decreasing costs of energy use, decreasing the carbon footprint by including renewable resources, and transforming the role of the occupant. At the crux of the smart home is an efficient electric energy management system that is enabled by emerging technologies in the electric grid and consumer electronics. This article presents a discussion of the state-of-the-art in electricity management in smart homes, the various enabling technologies that will accelerate this concept, and topics around consumer behavior with respect to energy usage.

  2. Web-based energy information systems for energy management and demand response in commercial buildings

    SciTech Connect (OSTI)

    Motegi, Naoya; Piette, Mary Ann; Kinney, Satkartar; Herter, Karen

    2003-04-18T23:59:59.000Z

    Energy Information Systems (EIS) for buildings are becoming widespread in the U.S., with more companies offering EIS products every year. As a result, customers are often overwhelmed by the quickly expanding portfolio of EIS feature and application options, which have not been clearly identified for consumers. The object of this report is to provide a technical overview of currently available EIS products. In particular, this report focuses on web-based EIS products for large commercial buildings, which allow data access and control capabilities over the Internet. EIS products combine software, data acquisition hardware, and communication systems to collect, analyze and display building information to aid commercial building energy managers, facility managers, financial managers and electric utilities in reducing energy use and costs in buildings. Data types commonly processed by EIS include energy consumption data; building characteristics; building system data, such as heating, ventilation, and air-conditioning (HVAC) and lighting data; weather data; energy price signals; and energy demand-response event information. This project involved an extensive review of research and trade literature to understand the motivation for EIS technology development. This study also gathered information on currently commercialized EIS. This review is not an exhaustive analysis of all EIS products; rather, it is a technical framework and review of current products on the market. This report summarizes key features available in today's EIS, along with a categorization framework to understand the relationship between EIS, Energy Management and Control Systems (EMCSs), and similar technologies. Four EIS types are described: Basic Energy Information Systems (Basic-EIS); Demand Response Systems (DRS); Enterprise Energy Management (EEM); and Web-based Energy Management and Control Systems (Web-EMCS). Within the context of these four categories, the following characteristics of EIS are discussed: Metering and Connectivity; Visualization and Analysis Features; Demand Response Features; and Remote Control Features. This report also describes the following technologies and the potential benefits of incorporating them into future EIS products: Benchmarking; Load Shape Analysis; Fault Detection and Diagnostics; and Savings Analysis.

  3. LESSONS LEARNED FROM CYBER SECURITY ASSESSMENTS OF SCADA AND ENERGY MANAGEMENT SYSTEMS

    SciTech Connect (OSTI)

    Ray Fink

    2006-10-01T23:59:59.000Z

    The results from ten cyber security vulnerability assessments of process control, SCADA and energy management systems, or components of those systems were reviewed to identify common problem areas. The common vulnerabilities ranged from conventional IT security issues to specific weaknesses in control system protocols. In each vulnerability category, relative measures were assigned to the severity of the vulnerability and ease with which an attacker could exploit the vulnerability. Suggested mitigations are identified in each category. Recommended mitigations having the highest impact on reducing vulnerability are listed for asset owners and system vendors.

  4. Federal Energy Management Program FY 2015 Budget At-A-Glance | Department

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers New Training on Energy ManagementAugustin2012)4 News5ManagementContactsof

  5. Federal Energy Management Program FY 2016 Budget At-A-Glance

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers New Training on Energy ManagementAugustin2012)4

  6. Federal Energy Management Program FY14 Budget At-a-Glance | Department of

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers New Training on Energy ManagementAugustin2012)4Energy Federal Energy

  7. Federal Energy Management Program FY14 Budget At-a-Glance | Department of

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers New Training on Energy ManagementAugustin2012)4Energy Federal

  8. O&M Best Practices - A Guide to Achieving Operational Efficiency (Release 2.0)

    SciTech Connect (OSTI)

    Sullivan, Gregory P.; Pugh, Ray; Melendez, Aldo P.; Hunt, W. D.

    2004-07-31T23:59:59.000Z

    This guide, sponsored by DOE's Federal Energy Management Program, highlights operations and maintenance (O&M) programs targeting energy efficiency that are estimated to save 5% to 20% on energy bills without a significant capital investment. The purpose of this guide is to provide the federal O&M energy manager and practitioner with useful information about O&M management, technologies, energy efficiency and cost-reduction approaches.

  9. Life-cycle costing manual for the federal energy management programs

    SciTech Connect (OSTI)

    Ruegg, R.T.

    1982-05-01T23:59:59.000Z

    This manual is a guide to understanding the life-cycle costing method and an aid to calculating the measures required for evaluating energy conservation and renewable energy investments in all Federal buildings. It expands upon the life-cycle costing criteria contained in the Program Rules of the Federal Energy Management Program (Subpart A of Part 436, Title 10, U.S. Code of Federal Regulations) and is consistent with those criteria. Its purpose is to facilitate the implementation of the Program Rules by explaining the life-cycle costing method, defining the measures, describing the assumptions and procedures to follow in performing evaluations, and giving examples. It provides worksheets, a computer program, and instructions for calculating the required measurements. The life-cycle costing method and evaluation procedures set forth in the Federal Energy Management Program Rules and described in greater detail in this guide are to be followed by all Federal agenecies for all energy conservation and renewable energy projects undertaken in new and existing buildings and facilities owned or leased by the Federal government, unless specifically exempted. The establishment of the methods and procedures and their use by Federal agencies to evaluate energy conservation and solar energy investments are required by Section 381(a)(2) of the Energy Policy and Conservation Act, as amended, 42 U.S.C. 6361(a)(2); by Section 10 of Presidential Executive Order 11912, amended; and by Title V of the National Energy Conservation Policy Act, 92 Stat. 3275.

  10. The decommodified security ratio

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    are currently experiencing: changing patterns of work, the phenom- enon she calls the "breakdown in the wage furthered by the work of the International Labour Office. In particular, the programme of researchThe decommodified security ratio: A tool for assessing European social protection systems Georges

  11. Energy Information Handbook: Applications for Energy-Efficient Building Operations

    E-Print Network [OSTI]

    Granderson, Jessica

    2013-01-01T23:59:59.000Z

    an energy management and energy audit; Chapter 8 Energyan energy management and energy audit; Chapter 8 Energyan energy management and energy audit; Chapter 8 Energy

  12. Multi-ratio transmission

    SciTech Connect (OSTI)

    Polak, J.C.

    1987-07-14T23:59:59.000Z

    A preselected multi-ratio power transmission is described comprising: input means for transmitting drive forces; output means; first, second and third friction clutch means each selectively engageable with the input means for accepting drive forces. First input gear means drivingly connects with the first friction clutch means; second input gear means drivingly connects with the second friction clutch means; third input gear means drivingly connects with the third clutch means; first output gear means drivingly connects with the first input gear means; second output gear means drivingly connects with the first and second input gear means; third output means drivingly connects between the third input gear means and the output means; and one double-acting synchronizer clutch for selectively engaging the first output gear means with the output means and alternately the second output gear means with the output means. The first friction clutch means and the one double-acting synchronizer clutch cooperates during engagement to establish two forward drive ratios between the input and output means. The second friction clutch means and the one double-acting synchronizer clutch cooperates during engagement to establish two other forward drive ratios between the input and output means. The third friction clutch means is engageable to provide another forward drive ratio between the input means and the output means; and the one double-acting synchronizer clutch is relieved of transmitting drive forces during the engagement of the third friction clutch means and being manipulable for alternate connection with either the first output gear or the second output gear while the third friction clutch means is engaged.

  13. Super Energy Savings Performance Contracts: Federal Energy Management Program (FEMP) Program Overview (revision)

    SciTech Connect (OSTI)

    Pitchford, P.

    2001-07-05T23:59:59.000Z

    This four-page publication describes the U.S. Department of Energy's (DOE's) streamlined energy savings performance contracting, or ''Super ESPC,'' process, which is managed by DOE's Federal Energy Management Program (FEMP). Under a Super ESPC, a qualifying energy service company (ESCO) from the private sector pays for energy efficiency improvements or advanced renewable energy technologies (e.g., photovoltaic systems, wind turbines, or geothermal heat pumps, among others) for a facility of a government agency. The ESCO is then repaid over time from the agency's resulting energy cost savings. Delivery orders under these contracts specify the level of performance (energy savings) and the repayment schedule; the contract term can be up to 25 years, although many Super ESPCs are for about 10 years or less.

  14. Domestic Water Conservation Technologies: Federal Energy Management Program (FEMP) Federal Technology Alert (Booklet)

    SciTech Connect (OSTI)

    Not Available

    2002-10-01T23:59:59.000Z

    Executive Order 13123 calls for the Federal government to conserve water as well as energy in its 500,000 facilities. To help set priorities among water-saving measures, the Federal Energy Management Program conducted a study of Federal water use in 1997. The study indicated that the government consumes more than 50% of its water in just three types of Federal facilities: housing, hospitals, and office buildings. These facilities have enough kitchens, rest rooms, and laundry areas to provide facility managers with many opportunities to begin reducing their water use (and utility costs) with appropriate water-saving fixtures and products. Therefore, this Federal Technology Alert focuses on domestic technologies, products, and appliances such as water-efficient faucets, showerheads, toilets, urinals, washing machines, and dishwashers. Conserving water also saves the energy needed to treat, pump, and heat that water in homes, businesses, and other buildings.

  15. Managing Server Energy and Operational Costs in Hosting Centers

    E-Print Network [OSTI]

    Lu, Jiaheng

    is the growing importance of energy/power consumption of these servers at the hosting centers, in termsManaging Server Energy and Operational Costs in Hosting Centers Yiyu Chen Dept. of IE Penn State.00. General Terms: Design, Performance Keywords: Energy Management, Performance Modeling, Feed- back Control

  16. ARM - Measurement - Isotope ratio

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadap Documentation TDMADAP : XDC documentationBarrow,ice particleSizegovMeasurementsIsotope ratio

  17. Stress-wave energy management through material anisotropy Alireza V. Amirkhizi, Aref Tehranian, Sia Nemat-Nasser

    E-Print Network [OSTI]

    Nemat-Nasser, Sia

    Stress-wave energy management through material anisotropy Alireza V. Amirkhizi, Aref Tehranian, Sia the required anisotropy, and to experimentally demonstrate the management of stress-wave energy in a desired that if this axis initially coincides with the stress-wave vector, then the energy of the plane waves would closely

  18. A near-Zero Run-time Energy Overhead within a Computation Outsourcing Framework for Energy Management in Mobile Devices

    E-Print Network [OSTI]

    Helal, Abdelsalam

    with a run-time monitoring system that consumes an extremely low amount of energy (near-Zero). This near Monitor, Battery Monitor. 1. Introduction Energy/Power management in mobile devices has been and continues incurring a near-Zero run-time overhead. Key Words- Energy Management, Outsourcing, Smart Spaces, Energy

  19. Energy management of power-split plug-in hybrid electric vehicles based on simulated annealing and Pontryagin's minimum principle

    E-Print Network [OSTI]

    Mi, Chunting "Chris"

    Energy management of power-split plug-in hybrid electric vehicles based on simulated annealing Accepted 14 August 2014 Available online 27 August 2014 Keywords: Plug-in hybrid electric vehicles Fuel-rate Pontryagin's minimum principle Simulated annealing State of health a b s t r a c t In this paper, an energy

  20. Managed by UT-Battelle for the U. S. Department of EnergyManaged by UT-Battelle

    E-Print Network [OSTI]

    Dasgupta, Dipankar

    Managed by UT-Battelle for the U. S. Department of EnergyManaged by UT-Battelle for the Department of Energy #12;Managed by UT-Battelle for the U. S. Department of Energy Outline · Motivation and Background by UT-Battelle for the U. S. Department of Energy Ultra ScienceNet: Motivation · Large-scale science

  1. What`s new in federal energy management: FEMP program overview. FEMP Renewable Energy Program

    SciTech Connect (OSTI)

    NONE

    1996-08-01T23:59:59.000Z

    As the owner or manager of more than 500,000 facilities, the US government has a superb opportunity to reduce fuel imports and improve environmental quality by using renewable sources of energy. In many Federal applications -- such as irrigation, water heating, indoor and outdoor lighting, or communications -- commercially available renewable technologies are often the most cost-effective option for supplying the needed energy, and they are environmentally friendly. The US Department of Energy, Federal Energy Management Program (FEMP) helps Federal agencies take advantage of the benefits offered by renewable technologies and apply the renewable provisions of the Energy Policy Act (EPAct) and Executive Order 12902. FEMP`s Renewable Energy Program educates Federal agencies about renewable opportunities and helps agencies implement successful renewable projects. And the opportunities are abundant. In new construction projects, for example, planners can optimize facility energy performance by incorporating renewable energy and energy efficiency measures early in the design process. Renewables are cost-effective in many retrofit projects. They are the clear choice for many remote sites that utility-supplied power does not reach. Their environmental advantages include either zero or reduced air emissions compared with conventional energy sources and no risk of fuel spills.

  2. An Effective EMS Hardware and Software Interface- The Trained Operator

    E-Print Network [OSTI]

    Cherry, C. L.

    AN EFFECTIVE EMS HARDWARE AND SOFTWARE THE TRAINED OPER~TQR Christene ~. Cherry Johnson Controls Institute INTERFACE Milwaukee, ABSTRAC'l' A computerized Energy Management Sys tem (EMS) is a tool that allows the user to moni tor... the importance of proper system design, installation and program application. The importance of having a trained EMS operator is less recognized. The purpose of this paper is to focus on structured training programs and how they can improve the EMS...

  3. Benefits and Drawbacks of Compression Ratio Reduction in PCCI...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    effect of compression ratio on performance of light duty diesel operating with PCCI calibration, near EURO6Tier 2 Bin 5 NOx limits. deer08beatrice.pdf More Documents &...

  4. Occupancy-Based Energy Management in Buildings: Final Report to Sponsors

    E-Print Network [OSTI]

    Sohn, Michael D.

    2010-01-01T23:59:59.000Z

    are goals used in energy efficient designs. For example, 1commitment to energy efficient building design and operation

  5. NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Maximizing Thermal Efficiency and

    E-Print Network [OSTI]

    and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Maximizing Thermal Efficiency energy management (AHEM), and energy storage systems, scientists uncover solutions for cost vehicle energy storage components and systems. Addressing Industry Challenges Industry seeks performance

  6. Net energy ratio of photobiohydrogen generation G. Burgessa

    E-Print Network [OSTI]

    Net energy ratio of photobiohydrogen generation G. Burgessa and J.G. Fernández the energy content, the operational energy inputs, and the net energy ratio (NER) of an industrial tubular photobioreactor used for the photosynthetic production of H2 by microalgae. The calculated H2 output

  7. High compression ratio turbo gasoline engine operation using alcohol enhancement

    E-Print Network [OSTI]

    Lewis, Raymond (Raymond A.)

    2013-01-01T23:59:59.000Z

    Gasoline - ethanol blends were explored as a strategy to mitigate engine knock, a phenomena in spark ignition engine combustion when a portion of the end gas is compressed to the point of spontaneous auto-ignition. This ...

  8. The New Energy Management Frontier: The Critical Role of a Systematic Management Approach in Making Technology Improvements Successful

    E-Print Network [OSTI]

    Feldman, J.

    The New Energy Management Frontier: The Critical Role of a Systematic Management Approach in Making Technology Improvements Successful Jon Feldman Senior Consultant Hatch Consulting Mississauga, Ontario, Canada ABSTRACT Improvements... in technology certainly playa pivotal role in the quest for increased energy efficiency. However, sophisticated industrial energy users are increasingly learning that technology alone cannot drive long-tenn, sustainable reductions in energy cost. The role...

  9. Energy Management in Small Commercial Buildings: A Look at How HVAC Contractors Can Deliver Energy Efficiency to this Segment

    SciTech Connect (OSTI)

    Hult, Erin; Granderson, Jessica; Mathew, Paul

    2014-07-01T23:59:59.000Z

    While buildings smaller than 50,000 sq ft account for nearly half of the energy used in US commercial buildings, energy efficiency programs to-date have primarily focused on larger buildings. Interviews with stakeholders and a review of the literature indicate interest in energy efficiency from the small commercial building sector, provided solutions are simple and low-cost. An approach to deliver energy management to small commercial buildings via HVAC contractors and preliminary demonstration findings are presented. The energy management package (EMP) developed includes five technical elements: benchmarking and analysis of monthly energy use; analysis of interval electricity data (if available), a one-hour onsite walkthrough, communication with the building owner, and checking of results. This data-driven approach tracks performance and identifies low-cost opportunities, using guidelines and worksheets for each element to streamline the delivery process and minimize the formal training required. This energy management approach is unique from, but often complementary to conventional quality maintenance or retrofit-focused programs targeting the small commercial segment. Because HVAC contractors already serve these clients, the transaction cost to market and deliver energy management services can be reduced to the order of hundreds of dollars per year. This business model, outlined briefly in this report, enables the offering to benefit the contractor and client even at the modest expected energy savings in small buildings. Results from a small-scale pilot of this approach validated that the EMP could be delivered by contractors in 4-8 hours per building per year, and that energy savings of 3-5percent are feasible through this approach.

  10. Mining Building Energy Management System Data Using Fuzzy Anomaly Detection and Linguistic Descriptions

    SciTech Connect (OSTI)

    Dumidu Wijayasekara; Ondrej Linda; Milos Manic; Craig Rieger

    2014-08-01T23:59:59.000Z

    Building Energy Management Systems (BEMSs) are essential components of modern buildings that utilize digital control technologies to minimize energy consumption while maintaining high levels of occupant comfort. However, BEMSs can only achieve these energy savings when properly tuned and controlled. Since indoor environment is dependent on uncertain criteria such as weather, occupancy, and thermal state, performance of BEMS can be sub-optimal at times. Unfortunately, the complexity of BEMS control mechanism, the large amount of data available and inter-relations between the data can make identifying these sub-optimal behaviors difficult. This paper proposes a novel Fuzzy Anomaly Detection and Linguistic Description (Fuzzy-ADLD) based method for improving the understandability of BEMS behavior for improved state-awareness. The presented method is composed of two main parts: 1) detection of anomalous BEMS behavior and 2) linguistic representation of BEMS behavior. The first part utilizes modified nearest neighbor clustering algorithm and fuzzy logic rule extraction technique to build a model of normal BEMS behavior. The second part of the presented method computes the most relevant linguistic description of the identified anomalies. The presented Fuzzy-ADLD method was applied to real-world BEMS system and compared against a traditional alarm based BEMS. In six different scenarios, the Fuzzy-ADLD method identified anomalous behavior either as fast as or faster (an hour or more), that the alarm based BEMS. In addition, the Fuzzy-ADLD method identified cases that were missed by the alarm based system, demonstrating potential for increased state-awareness of abnormal building behavior.

  11. Specification of an Information Delivery Tool to Support Optimal Holistic Environmental and Energy Management in Buildings

    E-Print Network [OSTI]

    O'Donnell, James

    2008-01-01T23:59:59.000Z

    Laboratory Buildings. ” Energy and Buildings 34 Geoghegan,consumption data. ” Energy and Buildings 24, Hampton, Dave.building operations. ” Energy and Buildings 33, (8):783–791.

  12. IEEE COMMUNICATIONS SURVEYS & TUTORIALS, ACCEPTED FOR PUBLICATION 1 Energy Management Techniques in

    E-Print Network [OSTI]

    Hand, Steven

    . However, the state of the art of lithium-ion batteries clearly indicates that energy efficiency must are powered by lithium- ion batteries that can provide many times the energy of other types of batteries the battery life of mobile handhelds to few hours of operation. The research community, and operating system

  13. Use of Metering for Facility and Whole Building Energy Analysis by the U.S. Depratment of Energy Federal Energy Management Program

    E-Print Network [OSTI]

    Devine, K. D.; Mazzucchi, R. P.

    1989-01-01T23:59:59.000Z

    This paper details how the U.S. Department of Energy, Federal Energy Management Program (FEMP) is applying metering technology to conduct empirically based analyses o f energy use by federal agencies. Continuing developments in sensors, data...

  14. Control and Optimization Meet the Smart Power Grid - Scheduling of Power Demands for Optimal Energy Management

    E-Print Network [OSTI]

    Koutsopoulos, Iordanis

    2010-01-01T23:59:59.000Z

    The smart power grid aims at harnessing information and communication technologies to enhance reliability and enforce sensible use of energy. Its realization is geared by the fundamental goal of effective management of demand load. In this work, we envision a scenario with real-time communication between the operator and consumers. The grid operator controller receives requests for power demands from consumers, with different power requirement, duration, and a deadline by which it is to be completed. The objective is to devise a power demand task scheduling policy that minimizes the grid operational cost over a time horizon. The operational cost is a convex function of instantaneous power consumption and reflects the fact that each additional unit of power needed to serve demands is more expensive as demand load increases.First, we study the off-line demand scheduling problem, where parameters are fixed and known. Next, we devise a stochastic model for the case when demands are generated continually and sched...

  15. Relative Investment Risks and Returns of Energy Management and Production Projects

    E-Print Network [OSTI]

    Gaffney, B. J.; Inyard, F. H.

    1983-01-01T23:59:59.000Z

    Engineering managers must routinely make decisions on how to allocate limited resources to achieve the most benefit. Energy conservation and increased or new productivity are two areas which compete for operating and capital budgets. This paper...

  16. The Role of Advanced Process Control in Your Energy Management Solution

    E-Print Network [OSTI]

    Johnson, K.; Van Wyk, L.

    2010-01-01T23:59:59.000Z

    "According to Aberdeen Group, Operational Excellence in the Process Industries - Driving Performance Through Real-time Visibility, the most striking advantage Best-in-Class companies have is being able to compare performance across a portfolio...

  17. A Practical Approach to Energy Management in a Large Petrochemical Manufacturing Facility

    E-Print Network [OSTI]

    Ackley, A.

    2005-01-01T23:59:59.000Z

    Plant is a highly integrated petrochemical complex on over 1000 acres, which operates seven process units, one olefins unit, two alpha olefins units, one poly alpha olefins unit, and three polyethylene units as well as a central utilities unit...

  18. Annual report to Congress on Federal Government Energy Management and Conservation Programs, Fiscal Year 1997

    SciTech Connect (OSTI)

    none,

    1999-08-13T23:59:59.000Z

    In fulfillment of statutory requirements, this report provides information on energy consumption in Federal buildings and operations and also documents activities conducted by Federal agencies in fulfilling those requirements during Fiscal Year 1997.

  19. Add me to your mailing list for future information about energy management courses.

    E-Print Network [OSTI]

    California at Davis, University of

    : energy economics, metering, performance contracting and financing with demand response, measurement and products, project management, fleet operation and maintenance, verification of energy savings, and best practices. Prerequisite: Introduction to Energy Resource Management Enroll now through Sept. 21 and complete

  20. The Role of Advanced Process Control in Your Energy Management Solution 

    E-Print Network [OSTI]

    Johnson, K.; Van Wyk, L.

    2010-01-01T23:59:59.000Z

    "According to Aberdeen Group, Operational Excellence in the Process Industries - Driving Performance Through Real-time Visibility, the most striking advantage Best-in-Class companies have is being able to compare performance ...

  1. Emissions and Energy: An Integral Approach Using an Online Energy Management and Optimization Model 

    E-Print Network [OSTI]

    Ruiz, D.; Ruiz, C.; Santollani, O.; Reitmeier, T.

    2010-01-01T23:59:59.000Z

    With the expected legislation on the horizon in the U.S., the cost of CO2 emissions will have significant impact on industrial plant operations in the near future. Our purpose in this presentation is to show real industrial ...

  2. Annual report to Congress on Federal Government Energy Management and Conservation Programs, Fiscal Year 1998

    SciTech Connect (OSTI)

    none,

    2000-03-20T23:59:59.000Z

    In fulfillment of statutory requirements, this report provides information on energy consumption in Federal buildings and operations and also documents activities conducted by Federal agencies in fulfilling those requirements during Fiscal Year 1998.

  3. High ratio recirculating gas compressor

    DOE Patents [OSTI]

    Weinbrecht, J.F.

    1989-08-22T23:59:59.000Z

    A high ratio positive displacement recirculating rotary compressor is disclosed. The compressor includes an integral heat exchanger and recirculation conduits for returning cooled, high pressure discharge gas to the compressor housing to reducing heating of the compressor and enable higher pressure ratios to be sustained. The compressor features a recirculation system which results in continuous and uninterrupted flow of recirculation gas to the compressor with no direct leakage to either the discharge port or the intake port of the compressor, resulting in a capability of higher sustained pressure ratios without overheating of the compressor. 10 figs.

  4. Operational costs induced by fluctuating wind power production in Germany and Scandinavia

    E-Print Network [OSTI]

    Operational costs induced by fluctuating wind power production in Germany and Scandinavia Peter Christoph Weber, Chair of Energy Management, University Duisburg-Essen, Germany Rüdiger Barth & Heike Brand, Institute of Energy Economics and the Rational Use of Energy, University of Stuttgart, Germany Abstract

  5. Augmented reality building operations tool

    DOE Patents [OSTI]

    Brackney, Larry J.

    2014-09-09T23:59:59.000Z

    A method (700) for providing an augmented reality operations tool to a mobile client (642) positioned in a building (604). The method (700) includes, with a server (660), receiving (720) from the client (642) an augmented reality request for building system equipment (612) managed by an energy management system (EMS) (620). The method (700) includes transmitting (740) a data request for the equipment (612) to the EMS (620) and receiving (750) building management data (634) for the equipment (612). The method (700) includes generating (760) an overlay (656) with an object created based on the building management data (634), which may be sensor data, diagnostic procedures, or the like. The overlay (656) is configured for concurrent display on a display screen (652) of the client (642) with a real-time image of the building equipment (612). The method (700) includes transmitting (770) the overlay (656) to the client (642).

  6. A Unified and Integrated Energy Management System for HVAC Spaces and Power House

    E-Print Network [OSTI]

    Kaya, A.; Debban, G. D.

    sense operations. Some of the are: control of lighting; shedding the loads on increase, electrical demand; operating the air moving fan intermittently to save energy. The interest here is 0 control and optimization methods to improve energ...", Bailey Controls Co., Wickliffe, Ohiq, U.S.A. 5. Matski, T.N., et ai, "Optimal Boiler Load Allocatior in Distributed Control", Proc. of 1962 ACq, Arlington, VA, USA. 6. Kaya, A., et ai, .. Load Control for Energ;y Converters", U.S. Patents 4, 412...

  7. Continuous Commissioning® and Energy Management Control Strategies at Alamo Community College District 

    E-Print Network [OSTI]

    Martinez, J.; Verdict, M.; Baltazar, J.C.

    2008-01-01T23:59:59.000Z

    optimization Limited boiler controls were available. They are staged on and off based of supply water temperature and are operated 24 hours a day. The simplest way to reduce energy consumption was to turn the boilers off when the outside air temperature... optimization Limited boiler controls were available. They are staged on and off based of supply water temperature and are operated 24 hours a day. The simplest way to reduce energy consumption was to turn the boilers off when the outside air temperature...

  8. Measuring savings in energy savings performance contracts using in-place energy management systems -- A case study

    SciTech Connect (OSTI)

    Heinemeier, K.E.; Akbari, H.; Kromer, S. [Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.

    1996-08-01T23:59:59.000Z

    Energy Management Control Systems (EMCSs) have been used in many projects as a monitoring device to provide information necessary for estimating savings from efficiency measures. This paper discusses a case study that looked in great depth at that use for evaluating savings in Energy Savings Performance Contracting (ESPC). ESPC is one of the increasingly important mechanisms for profiting from energy efficiency in commercial buildings. With ESPC, a contractor finances and installs energy-conversion measures, and the resulting savings in energy bills are shared between the contractor and the building owner. Hence, the method used for determining savings is key to the success of this financing scheme. As a part of their effort to establish measurement and verification methods, the Federal Energy Management Program (FEMP) carried out a pilot study of ESPC, and the EMCS was used in the savings verification for this ESPC contract. This case study also serves as a detailed and quantitative comparison of EMCS and conventional monitoring techniques, according to the guidelines developed in earlier work. This paper discusses the concept of different levels of monitoring savings for ESPC and presents an assessment of the use of EMCS for these levels of monitoring.

  9. Energy Management for Hypervisor-Based Virtual Machines Jan Stoess Christian Lang Frank Bellosa

    E-Print Network [OSTI]

    Yang, Junfeng

    data acquisition system demonstrate that our framework accurately controls and stipulates the power or energy constraints. A monolithic kernel also controls the whole execution flow in the system. It can Current approaches to power management are based on operating systems with full knowledge of and full

  10. Fuzzy Based Energy Management Control of A Hybrid Fuel Cell Auxiliary Power System

    E-Print Network [OSTI]

    Simões, Marcelo Godoy

    battery auxiliary power unit (APU) for remote applications where a fuel cell is the main energy source for decentralized or distributed energy production, such as telecom, remote sites or even for military applications by hydrogen cartridges a fuel cell has nearly no noise operation, providing electricity and heat with water

  11. Corporate Energy Management- Book II or What To Do For An Encore

    E-Print Network [OSTI]

    Spencer, R. J.

    reminder that energy efficiency is important. New Technology General Motors is moving into new technology by installation of several circulating fluidized bed boilers and also cogeneration equipment. Construction of a 300,000 pound per hour... circulating fluidized bed boiler is near ingcompletion at the Pontiac Motors Division at Pontiac, Michigan. The new boiler operates at 1450 psigpressure supplying steam to a 27 megawatt turbine generator which represents about 30% of electrical usage. A...

  12. Operations & Maintenance

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Operations and Maintenance Operations OASIS: OATI (Note: this site is not hosted by Western and requires a digital certificate and login for full access.) Contact Information...

  13. Operations & Maintenance

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rates Operations & Maintenance Operations OASIS: WACM (Note: this site is not hosted by Western and requires a digital certificate and login for full access.) wesTTrans Common...

  14. Operations & Maintenance Best Practices - A Guide to Achieving Operational Efficiency (Release 3)

    SciTech Connect (OSTI)

    Sullivan, Greg; Pugh, Ray; Melendez, Aldo P.; Hunt, W. D.

    2010-08-04T23:59:59.000Z

    This guide highlights operations and maintenance programs targeting energy and water efficiency that are estimated to save 5% to 20% on energy bills without a significant capital investment. The purpose of this guide is to provide you, the Operations and Maintenance (O&M)/Energy manager and practitioner, with useful information about O&M management, technologies, energy and water efficiency, and cost-reduction approaches. To make this guide useful and to reflect your needs and concerns, the authors met with O&M and Energy managers via Federal Energy Management Program (FEMP) workshops. In addition, the authors conducted extensive literature searches and contacted numerous vendors and industry experts. The information and case studies that appear in this guide resulted from these activities. It needs to be stated at the outset that this guide is designed to provide information on effective O&M as it applies to systems and equipment typically found at Federal facilities. This guide is not designed to provide the reader with step-by-step procedures for performing O&M on any specific piece of equipment. Rather, this guide first directs the user to the manufacturer's specifications and recommendations. In no way should the recommendations in this guide be used in place of manufacturer's recommendations. The recommendations in this guide are designed to supplement those of the manufacturer, or, as is all too often the case, provide guidance for systems and equipment for which all technical documentation has been lost. As a rule, this guide will first defer to the manufacturer's recommendations on equipment operation and maintenance.

  15. DuPont Approach to Energy Management: A System Wide Approach to Energy Efficiency 

    E-Print Network [OSTI]

    Stewart, J. W.

    1998-01-01T23:59:59.000Z

    the Twentieth National Industrial Energy Technology Conference, Houston, TX, April 22-23, 1998 DuPont is a major industrial consumer of energy in the form of fuels and electricity. In fact, DuPont's global annual energy spending is about $1.5 billion which has... three equal components (Figure 5): ? Purchased electricity ? Purchased fuels ? Operating and maintenance Like all large energy consumers, DuPont worked very hard to improve energy efficiency following the 1974 OPEC oil embargo and the "oil shocks...

  16. Denver Federal Center Saves Energy, Forges Partnerships Through Super ESPC. Federal Energy Management Program (FEMP) ESPC Case Study

    SciTech Connect (OSTI)

    Not Available

    2002-01-01T23:59:59.000Z

    The General Services Administration is not just replacing aging heating and cooling equipment and reducing maintenance costs at the 670-acre Denver Federal Center (DFC). The GSA is also helping the government save about $450,000 in annual energy costs, conserve nearly 11 million gallons of water per year, and reduce annual carbon dioxide emissions by 15.9 million pounds, all by making use of the Department of Energy's Super Energy Savings Performance Contracts (Super ESPCs) at the DFC. Under these contracts, an energy services provider pays the up-front project costs and is then repaid over the contracts term out of the resulting energy cost savings. This two-page case study, prepared by NREL for the DOE Federal Energy Management Program (FEMP), demonstrates how the GSA forged new project partnerships, improved the DFCs boiler plant, and acquired efficient new chillers, motors, controls, and lighting by placing two delivery orders for this work under FEMPs Central Region Super ESPC.

  17. An Evaluation of the Federal Energy Management Program Technical Assistance Workshops: Results of a 1998 Customer Survey

    SciTech Connect (OSTI)

    G. B. Gordon; N. Hall

    1999-04-01T23:59:59.000Z

    This report presents the results of a customer telephone survey of the participants of six workshops provided by the U. S. Department of Energy Federal Energy Management Program (FEMP) during calendar years 1995 and 1996. The primary purpose for the survey was to provide the Team Leader for FEMP Technical Assistance and members of the team with detailed customer feedback pertaining to how well selected FEMP workshops are doing and to identify areas for improvement. The information presented enables managers to see both the strengths of their workshops, as well as workshop components that can be improved. In addition, the report identifies the questions included in the survey that were the most productive for obtaining customers experiences, opinions and recommendations. The experiences gained during this survey provide a platform from which to launch an annual FEMP customer survey.

  18. Advanced Hybrid Propulsion and Energy Management System for High Efficiency, Off Highway, 240 Ton Class, Diesel Electric Haul Trucks

    SciTech Connect (OSTI)

    Richter, Tim; Slezak, Lee; Johnson, Chris; Young, Henry; Funcannon, Dan

    2008-12-31T23:59:59.000Z

    The objective of this project is to reduce the fuel consumption of off-highway vehicles, specifically large tonnage mine haul trucks. A hybrid energy storage and management system will be added to a conventional diesel-electric truck that will allow capture of braking energy normally dissipated in grid resistors as heat. The captured energy will be used during acceleration and motoring, reducing the diesel engine load, thus conserving fuel. The project will work towards a system validation of the hybrid system by first selecting an energy storage subsystem and energy management subsystem. Laboratory testing at a subscale level will evaluate these selections and then a full-scale laboratory test will be performed. After the subsystems have been proven at the full-scale lab, equipment will be mounted on a mine haul truck and integrated with the vehicle systems. The integrated hybrid components will be exercised to show functionality, capability, and fuel economy impacts in a mine setting.

  19. Audits and Implementation of Plant Wide Energy Management and Reporting Systems

    E-Print Network [OSTI]

    Robinson, J.; Moore, D.

    2006-01-01T23:59:59.000Z

    on the FFE Performance Chart. TARGET PROFILE - PB#4 and PB#5 REMOVED Previous Advanced Control System - 1/1 to 12/31/2004 - 7,382 Hours 2004 Power Boiler PB#1, PB#2, and PB#3 - Ex PB#4, and PB#5 Fossil Fuel Effectiveness (FFE) Performance Analysis 0... - PB4 and PB5 Removed Previous Advanced Control Operational 1/1 to 12/31/2004-7,382 Hours Power Boiler PB#1, PB#2, and PB#3 - Excluding PB#4 and PB#5 Fossil Fuel Effectiveness (FFE) Relative to Steam Generation 0.000 0.200 0.400 0.600 0.800 1.000 1...

  20. Annual report to Congress on Federal Government energy management and conservation programs, Fiscal year 1994

    SciTech Connect (OSTI)

    NONE

    1995-10-06T23:59:59.000Z

    This report provides sinformation on energy consumption in Federal buildings and operations and documents activities conducted by Federal agencies to meet statutory requirements of the National Energy Conservation Policy Act. It also describes energy conservation and management activities of the Federal Government under section 381 of the Energy Policy and Conservation Act. Implementation activities undertaken during FY94 by the Federal agencies under the Energy Policy Act of 1992 and Executive Orders 12759 and 12902 are also described. During FY94, total (gross) energy consumption of the US Government, including energy consued to produce, process, and transport energy, was 1.72 quadrillion Btu. This represents {similar_to}2.0% of the total 85.34 quads used in US.

  1. Hydraulic system for a ratio change transmission

    DOE Patents [OSTI]

    Kalns, Ilmars (Northville, MI)

    1981-01-01T23:59:59.000Z

    Disclosed is a drive assembly (10) for an electrically powered vehicle (12). The assembly includes a transaxle (16) having a two-speed transmission (40) and a drive axle differential (46) disposed in a unitary housing assembly (38), an oil-cooled prime mover or electric motor (14) for driving the transmission input shaft (42), an adapter assembly (24) for supporting the prime mover on the transaxle housing assembly, and a hydraulic system (172) providing pressurized oil flow for cooling and lubricating the electric motor and transaxle and for operating a clutch (84) and a brake (86) in the transmission to shift between the two-speed ratios of the transmission. The adapter assembly allows the prime mover to be supported in several positions on the transaxle housing. The brake is spring-applied and locks the transmission in its low-speed ratio should the hydraulic system fail. The hydraulic system pump is driven by an electric motor (212) independent of the prime mover and transaxle.

  2. A Light-weight Approach to Reducing Energy Management Delays in Disks Guanying Wang, Ali R. Butt, Chris Gniady, Puranjoy Bhattacharjee

    E-Print Network [OSTI]

    Butt, Ali R.

    systems overnight [6] to reduce energy costs. Setups such as academic institutions and businesses, where- end applications. These computers consume a lot of energy whose monetary cost accounts techniques such as turning machines off overnight and dynamic energy management during the business hours

  3. Sustainability Dashboard Quick Start Guide The Sustainability Dashboard is a web based energy management system that allows users to track a

    E-Print Network [OSTI]

    energy management system that allows users to track a building's performance, generate reports individual meters, click on Meter Displays under the main menu item, Graphics & Displays. Then select, energy log and time period parameters to generate custom reports. Figure 9: Utility Report Wizard To use

  4. Fuzzy-PID control for multisource energy management in buildings Benjamin Paris (1), Julien Eynard (1), Frdrik Thiry (1), Adama Traor (1), Thierry Talbert (1)

    E-Print Network [OSTI]

    Boyer, Edmond

    the reactivity, and avoids energy waste: just a few of electricity is consummated to heat the mock-up. Thus facilities to achieve energy savings, especially concerning heating installations. Thus, energy management entails reducing fossil energy consumption and enhancing renewable energy supply using different heating

  5. Envera Variable Compression Ratio Engine

    SciTech Connect (OSTI)

    Charles Mendler

    2011-03-15T23:59:59.000Z

    Aggressive engine downsizing, variable compression ratio and use of the Atkinson cycle are being combined to improve fuel economy by up to 40 percent relative to port fuel injected gasoline engines, while maintaining full engine power. Approach Engine downsizing is viewed by US and foreign automobile manufacturers as one of the best options for improving fuel economy. While this strategy has already demonstrated a degree of success, downsizing and fuel economy gains are currently limited. With new variable compression ratio technology however, the degree of engine downsizing and fuel economy improvement can be greatly increased. A small variable compression ratio (VCR) engine has the potential to return significantly higher vehicle fuel economy while also providing high power. Affordability and potential for near term commercialization are key attributes of the Envera VCR engine. VCR Technology To meet torque and power requirements, a smaller engine needs to do more work per stroke. This is typically accomplished by boosting the incoming charge with either a turbo or supercharger so that more energy is present in the cylinder per stroke to do the work. With current production engines the degree of engine boosting (which correlates to downsizing) is limited by detonation (combustion knock) at high boost levels. Additionally, the turbo or supercharger needs to be responsive and efficient while providing the needed boost. VCR technology eliminates the limitation of engine knock at high load levels by reducing compression ratio to {approx}9:1 (or whatever level is appropriate) when high boost pressures are needed. By reducing the compression ratio during high load demand periods there is increased volume in the cylinder at top dead center (TDC) which allows more charge (or energy) to be present in the cylinder without increasing the peak pressure. Cylinder pressure is thus kept below the level at which the engine would begin to knock. When loads on the engine are low the compression ratio can be raised (to as much as 18:1) providing high engine efficiency. It is important to recognize that for a well designed VCR engine cylinder pressure does not need to be higher than found in current production turbocharged engines. As such, there is no need for a stronger crankcase, bearings and other load bearing parts within the VCR engine. The Envera VCR mechanism uses an eccentric carrier approach to adjust engine compression ratio. The crankshaft main bearings are mounted in this eccentric carrier or 'crankshaft cradle' and pivoting the eccentric carrier 30 degrees adjusts compression ratio from 9:1 to 18:1. The eccentric carrier is made up of a casting that provides rigid support for the main bearings, and removable upper bearing caps. Oil feed to the main bearings transits through the bearing cap fastener sockets. The eccentric carrier design was chosen for its low cost and rigid support of the main bearings. A control shaft and connecting links are used to pivot the eccentric carrier. The control shaft mechanism features compression ratio lock-up at minimum and maximum compression ratio settings. The control shaft method of pivoting the eccentric carrier was selected due to its lock-up capability. The control shaft can be rotated by a hydraulic actuator or an electric motor. The engine shown in Figures 3 and 4 has a hydraulic actuator that was developed under the current program. In-line 4-cylinder engines are significantly less expensive than V engines because an entire cylinder head can be eliminated. The cost savings from eliminating cylinders and an entire cylinder head will notably offset the added cost of the VCR and supercharging. Replacing V6 and V8 engines with in-line VCR 4-cylinder engines will provide high fuel economy at low cost. Numerous enabling technologies exist which have the potential to increase engine efficiency. The greatest efficiency gains are realized when the right combination of advanced and new technologies are packaged together to provide the greatest gains at the least cost. Aggressive engine downsiz

  6. The impact of equivalence ratio oscillations on combustion dynamics in a backward-facing step combustor

    SciTech Connect (OSTI)

    Murat Altay, H.; Speth, Raymond L.; Hudgins, Duane E.; Ghoniem, Ahmed F. [Massachusetts Institute of Technology, Department of Mechanical Engineering, Cambridge, MA 02139 (United States)

    2009-11-15T23:59:59.000Z

    The combustion dynamics of propane-air flames are investigated in an atmospheric pressure, atmospheric inlet temperature, lean, premixed backward-facing step combustor. We modify the location of the fuel injector to examine the impact of equivalence ratio oscillations arriving at the flame on the combustion dynamics. Simultaneous pressure, velocity, heat-release rate and equivalence ratio measurements and high-speed video from the experiments are used to identify and characterize several distinct operating modes. When the fuel is injected far upstream from the step, the equivalence ratio arriving at the flame is steady and the combustion dynamics are controlled only by flame-vortex interactions. In this case, different dynamic regimes are observed depending on the operating parameters. When the fuel is injected close to the step, the equivalence ratio arriving at the flame exhibits oscillations. In the presence of equivalence ratio oscillations, the measured sound pressure level is significant across the entire range of lean mean equivalence ratios even if the equivalence ratio oscillations arriving at the flame are out-of-phase with the pressure oscillations. The combustion dynamics are governed primarily by the flame-vortex interactions, while the equivalence ratio oscillations have secondary effects. The equivalence ratio oscillations could generate variations in the combustion dynamics in each cycle under some operating conditions, destabilize the flame at the entire range of the lean equivalence ratios, and increase the value of the mean equivalence ratio at the lean blowout limit. (author)

  7. Variable ratio regenerative braking device

    DOE Patents [OSTI]

    Hoppie, Lyle O. (Birmingham, MI)

    1981-12-15T23:59:59.000Z

    Disclosed is a regenerative braking device (10) for an automotive vehicle. The device includes an energy storage assembly (12) having a plurality of rubber rollers (26, 28) mounted for rotation between an input shaft (36) and an output shaft (42), clutches (38, 46) and brakes (40, 48) associated with each shaft, and a continuously variable transmission (22) connectable to a vehicle drivetrain and to the input and output shafts by the respective clutches. The rubber rollers are torsionally stressed to accumulate energy from the vehicle when the input shaft is clutched to the transmission while the brake on the output shaft is applied, and are torsionally relaxed to deliver energy to the vehicle when the output shaft is clutched to the transmission while the brake on the input shaft is applied. The transmission ratio is varied to control the rate of energy accumulation and delivery for a given rotational speed of the vehicle drivetrain.

  8. Continuous Energy Management of the HVAC&R System in an Office Building System Operation and Energy Consumption for the Eight Years after Building Completion

    E-Print Network [OSTI]

    Akashi, Y.; Shinozaki, M.; Kusuda, R.; Ito, S.

    2006-01-01T23:59:59.000Z

    setting was detected, and the system performance improved significantly as a result of correcting the fault. Recently, however, problematic issues, such as the malfunction of chillers and deteriorated performance of the heat exchangers, have emerged...

  9. Weather-Corrected Performance Ratio

    SciTech Connect (OSTI)

    Dierauf, T.; Growitz, A.; Kurtz, S.; Cruz, J. L. B.; Riley, E.; Hansen, C.

    2013-04-01T23:59:59.000Z

    Photovoltaic (PV) system performance depends on both the quality of the system and the weather. One simple way to communicate the system performance is to use the performance ratio (PR): the ratio of the electricity generated to the electricity that would have been generated if the plant consistently converted sunlight to electricity at the level expected from the DC nameplate rating. The annual system yield for flat-plate PV systems is estimated by the product of the annual insolation in the plane of the array, the nameplate rating of the system, and the PR, which provides an attractive way to estimate expected annual system yield. Unfortunately, the PR is, again, a function of both the PV system efficiency and the weather. If the PR is measured during the winter or during the summer, substantially different values may be obtained, making this metric insufficient to use as the basis for a performance guarantee when precise confidence intervals are required. This technical report defines a way to modify the PR calculation to neutralize biases that may be introduced by variations in the weather, while still reporting a PR that reflects the annual PR at that site given the project design and the project weather file. This resulting weather-corrected PR gives more consistent results throughout the year, enabling its use as a metric for performance guarantees while still retaining the familiarity this metric brings to the industry and the value of its use in predicting actual annual system yield. A testing protocol is also presented to illustrate the use of this new metric with the intent of providing a reference starting point for contractual content.

  10. Federal Energy Management Program technical assistance case study: The Forrestal Building relighting project saves $400K annually

    SciTech Connect (OSTI)

    NONE

    1997-01-01T23:59:59.000Z

    The US Department of Energy (DOE) believes energy efficiency begins at home -- in this case the James A. Forrestal Building in Washington, D.C. Since 1969, the 1.7 million-square-foot Forrestal Building has served as DOE Headquarters. In 1989, a team of in-house energy specialists began searching for opportunities to make the Forrestal Building more energy efficient. The team, on which personnel from the Federal Energy Management Program (FEMP) served, identified lighting as an area in which energy use could be reduced substantially. A monitoring program showed that the building`s more than 34,000 1-foot by 4-foot fluorescent lighting fixtures were responsible for 33% of the building`s total annual electric energy use, which represents more than 9 million kilowatt-hours (kWh) per year. In initiating the relighting program, DOE hoped to achieve these broad goals: Reduce energy use and utility bills, and improve lighting quality by distributing the light more uniformly. Funding was also an important consideration. DOE sought financing alternatives through which the lighting retrofit is paid for without using government-appropriated capital funds. DOE cut lighting costs more than 50% and paid for the project with the money saved on energy bills.

  11. Use of Energy Management and Control Systems for Performance Monitoring of Retrofit Projects: Final Summary Report for USDOE Office of Conservation and Energy, Final Revision, March 1993

    E-Print Network [OSTI]

    Claridge, D. E.; Haberl, J. S.; Sparks, R. J.; Bryant, J.; Poyner, B.; Belur, R.; Bryant, J.; Akbari, H.; Heinemeier, K. E.; Lippman, R.; McBride, J.

    1991-01-01T23:59:59.000Z

    for Appropriate Technology, Butte, Montana September 1991, First Revision March 1992, Final Revision March 1993 USDOE EMCS Report p. i 1.0 Executive Summary Traditionally, Energy Management and Control Systems (EMCSs) have been used to control HVAC, lighting, fire... of utilizing existing systems for energy monitoring at LoanSTAR sites. Energy Systems Laboratory, Texas A&M University March 1993 USDOE EMCS Report p. ii This EMCS Performance Monitoring project consists of three major tasks: (1) review the monitoring...

  12. Implementing an Energy Management System at TOTAL Prot Arthur Refinery: The process to improving and sustaining energy efficiency performance at a facility.

    E-Print Network [OSTI]

    Hoyle, A.

    2013-01-01T23:59:59.000Z

    PROPRIETARY INFORMATION? 2011 KBC Advanced Technologies plc. All Rights Reserved. Implementing an Energy Management System at TOTAL Port Arthur Refinery: The process to improving and sustaining energy efficiency performance at a facility May... Improvements ? Cost-savings initiatives ? Increasing environmental awareness ? Increasing throughput by debottlenecking processes ? Increasing government mandates 2May 2013 Energy Costs for a 200kBPD Complex refinery Typically, energy efficiency programs...

  13. Strategic Energy Management

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy (DOE) See Action Network and Weatherization and Intergovernmental Program Technical Assistance Program sponsored this webinar about strategic management in the public sector on November 7, 2012.

  14. Puddle Dynamics and Air-to-Fuel Ratio Compensation for Gasoline-Ethanol Blends in

    E-Print Network [OSTI]

    Stefanopoulou, Anna

    1 Puddle Dynamics and Air-to-Fuel Ratio Compensation for Gasoline-Ethanol Blends in Flex-Fuel flexible fuel vehicles (FFVs) can operate on a blend of gasoline and ethanol in any concentration of up for gasoline-ethanol blends is, thus, necessary for the purpose of air-to-fuel ratio control. In this paper, we

  15. GRID INDEPENDENT FUEL CELL OPERATED SMART HOME

    SciTech Connect (OSTI)

    Dr. Mohammad S. Alam

    2003-12-07T23:59:59.000Z

    A fuel cell power plant, which utilizes a smart energy management and control (SEMaC) system, supplying the power need of laboratory based ''home'' has been purchased and installed. The ''home'' consists of two rooms, each approximately 250 sq. ft. Every appliance and power outlet is under the control of a host computer, running the SEMaC software package. It is possible to override the computer, in the event that an appliance or power outage is required. Detailed analysis and simulation of the fuel cell operated smart home has been performed. Two journal papers has been accepted for publication and another journal paper is under review. Three theses have been completed and three additional theses are in progress.

  16. Operating Costs

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1997-03-28T23:59:59.000Z

    This chapter is focused on capital costs for conventional construction and environmental restoration and waste management projects and examines operating cost estimates to verify that all elements of the project have been considered and properly estimated.

  17. Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

    E-Print Network [OSTI]

    Stadler, Michael

    2010-01-01T23:59:59.000Z

    heat exchangers, solar thermal collectors, absorptionunits in operation or heat from solar thermal systems may bein the case of PV or solar thermal equipment, by available

  18. Currentcy: A Unifying Abstraction for Expressing Energy Management Heng Zeng, Carla S. Ellis, Alvin R. Lebeck, and Amin Vahdat

    E-Print Network [OSTI]

    Vahdat, Amin

    ,carla,alvy,vahdat}@cs.duke.edu Abstract The global nature of energy creates challenges and opportunities for developing operating system carry out this exploration in ECOSystem, an "energy- centric" Linux-based operating system. We extend Energy is an increasingly important system resource. This is most evident in battery-powered mobile com

  19. Energy Management and Control Systems and their Use for Performance Monitoring in the LoanSTAR Program, Technical Report prepared for the Lawrence Berkeley Laboratory, University of California, Energy and Environment Division

    E-Print Network [OSTI]

    Heinemeier, K. E.; Akbari, H.

    1993-01-01T23:59:59.000Z

    ESL-TR-93/06-02 LBL-33114 UC-350 LAWRENCE BERKELEY LABORATORY UNIVERSITY OF CALIFORNIA ENERGY AND ENVIRONMENT DIVISION ENERGY MANAGEMENT AND CONTROL SYSTEMS AND THEIR USE FOR PERFORMANCE MONITORING IN THE LOANSTAR PROGRAM Final Report Prepared...

  20. Operations Videos

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)IntegratedSpeeding access toTest and EvaluationOperational ManagementCenterOperations

  1. Eccentric crank variable compression ratio mechanism

    DOE Patents [OSTI]

    Lawrence, Keith Edward (Kobe, JP); Moser, William Elliott (Peoria, IL); Roozenboom, Stephan Donald (Washington, IL); Knox, Kevin Jay (Peoria, IL)

    2008-05-13T23:59:59.000Z

    A variable compression ratio mechanism for an internal combustion engine that has an engine block and a crankshaft is disclosed. The variable compression ratio mechanism has a plurality of eccentric disks configured to support the crankshaft. Each of the plurality of eccentric disks has at least one cylindrical portion annularly surrounded by the engine block. The variable compression ratio mechanism also has at least one actuator configured to rotate the plurality of eccentric disks.

  2. Abundance Ratios in Early-Type Galaxies

    E-Print Network [OSTI]

    Reynier Peletier

    1999-04-21T23:59:59.000Z

    Although evidence is accumulating that abundance ratios in galaxies are often non-solar, they are far from understood. I resume the current evidence for non-solar abundance ratios, supplementing the recent review by Worthey (1998) with some new results. It appears that the Mg/Fe abundance ratio only depends on the mass of the galaxy, not on the formation time-scale. For massive galaxies [Mg/Fe] > 0, while small galaxies show solar abundance ratios. Information about abundances of other element is scarce, but new evidence is given that [Ca/Fe] is solar, or slightly lower than solar, contrary to what is expected for an alpha-element.

  3. Allowable pillar to diameter ratio for strategic petroleum reserve caverns.

    SciTech Connect (OSTI)

    Ehgartner, Brian L.; Park, Byoung Yoon

    2011-05-01T23:59:59.000Z

    This report compiles 3-D finite element analyses performed to evaluate the stability of Strategic Petroleum Reserve (SPR) caverns over multiple leach cycles. When oil is withdrawn from a cavern in salt using freshwater, the cavern enlarges. As a result, the pillar separating caverns in the SPR fields is reduced over time due to usage of the reserve. The enlarged cavern diameters and smaller pillars reduce underground stability. Advances in geomechanics modeling enable the allowable pillar to diameter ratio (P/D) to be defined. Prior to such modeling capabilities, the allowable P/D was established as 1.78 based on some very limited experience in other cavern fields. While appropriate for 1980, the ratio conservatively limits the allowable number of oil drawdowns and hence limits the overall utility and life of the SPR cavern field. Analyses from all four cavern fields are evaluated along with operating experience gained over the past 30 years to define a new P/D for the reserve. A new ratio of 1.0 is recommended. This ratio is applicable only to existing SPR caverns.

  4. Ratio model serves suprathreshold color luminance discrimination

    E-Print Network [OSTI]

    Mullen, Kathy T.

    Ratio model serves suprathreshold color­ luminance discrimination Marcel J. Sankeralli and Kathy T quadrants of the red­ green/luminance and blue­yellow/luminance planes of cardinal color space. We showed model of suprathreshold color­luminance dis- crimination, in which discrimination depends on a ratio

  5. Operation Poorman

    SciTech Connect (OSTI)

    Pruvost, N.; Tsitouras, J.

    1981-03-18T23:59:59.000Z

    The objectives of Operation Poorman were to design and build a portable seismic system and to set up and use this system in a cold-weather environment. The equipment design uses current technology to achieve a low-power, lightweight system that is configured into three modules. The system was deployed in Alaska during wintertime, and the results provide a basis for specifying a mission-ready seismic verification system.

  6. Operating Strategies

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for RenewableSpeeding accessSpeedingOctoberResearchOpen→ globalOPERATING PLAN

  7. Operations Office

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for RenewableSpeeding accessSpeedingOctoberResearchOpen→ globalOPERATING

  8. High Transformer ratios in collinear wakefield accelerators.

    SciTech Connect (OSTI)

    Power, J. G.; Conde, M.; Yusof, Z.; Gai, W.; Jing, C.; Kanreykin, A.; Schoessow, P.; High Energy Physics; Euclid Techlabs, LLC

    2008-01-01T23:59:59.000Z

    Based on our previous experiment that successfully demonstrated wakefield transformer ratio enhancement in a 13.625 GHz dielectric-loaded collinear wakefield accelerator using the ramped bunch train technique, we present here a redesigned experimental scheme for even higher enhancement of the efficiency of this accelerator. Design of a collinear wakefield device with a transformer ratio R2, is presented. Using a ramped bunch train (RBT) rather than a single drive bunch, the enhanced transformer ratio (ETR) technique is able to increase the transformer ratio R above the ordinary limit of 2. To match the wavelength of the fundamental mode of the wakefield with the bunch length (sigmaz=2 mm) of the new Argonne wakefield accelerator (AWA) drive gun (where the experiment will be performed), a 26.625 GHz dielectric based accelerating structure is required. This transformer ratio enhancement technique based on our dielectric-loaded waveguide design will result in a compact, high efficiency accelerating structures for future wakefield accelerators.

  9. An operational analysis of flashing traffic signal operation

    E-Print Network [OSTI]

    Benz, Robert Joseph

    1993-01-01T23:59:59.000Z

    AN OPERATIONAL ANALYSIS OF FLASHING TRAFFIC SIGNAL OPERATION A Thesis by ROBERT JOSEPH BENZ Submitted to the Office of Graduate Studies of Texas AEcM University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE... street volumes are below 250 vph per approach and for main street volume of 500 vph per approach when the main/minor street volume ratio is above two. The volume range exceeds the Warrant 1 the minimum volume warrant for traffic signal installation...

  10. Operational Excellence

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItemResearch > TheNuclear Astrophysics One ofSpeedingthis site » OpenOperational

  11. Operations Information

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for RenewableSpeeding accessSpeedingOctoberResearchOpen→ globalOPERATING Who We

  12. Periodic equivalence ratio modulation method and apparatus for controlling combustion instability

    DOE Patents [OSTI]

    Richards, George A. (Morgantown, WV); Janus, Michael C. (Baltimore, MD); Griffith, Richard A. (Morgantown, WV)

    2000-01-01T23:59:59.000Z

    The periodic equivalence ratio modulation (PERM) method and apparatus significantly reduces and/or eliminates unstable conditions within a combustion chamber. The method involves modulating the equivalence ratio for the combustion device, such that the combustion device periodically operates outside of an identified unstable oscillation region. The equivalence ratio is modulated between preselected reference points, according to the shape of the oscillation region and operating parameters of the system. Preferably, the equivalence ratio is modulated from a first stable condition to a second stable condition, and, alternatively, the equivalence ratio is modulated from a stable condition to an unstable condition. The method is further applicable to multi-nozzle combustor designs, whereby individual nozzles are alternately modulated from stable to unstable conditions. Periodic equivalence ratio modulation (PERM) is accomplished by active control involving periodic, low frequency fuel modulation, whereby low frequency fuel pulses are injected into the main fuel delivery. Importantly, the fuel pulses are injected at a rate so as not to affect the desired time-average equivalence ratio for the combustion device.

  13. Control system and method for a power delivery system having a continuously variable ratio transmission

    DOE Patents [OSTI]

    Frank, A.A.

    1984-07-10T23:59:59.000Z

    A control system and method for a power delivery system, such as in an automotive vehicle, having an engine coupled to a continuously variable ratio transmission (CVT). Totally independent control of engine and transmission enable the engine to precisely follow a desired operating characteristic, such as the ideal operating line for minimum fuel consumption. CVT ratio is controlled as a function of commanded power or torque and measured load, while engine fuel requirements (e.g., throttle position) are strictly a function of measured engine speed. Fuel requirements are therefore precisely adjusted in accordance with the ideal characteristic for any load placed on the engine. 4 figs.

  14. Control system and method for a power delivery system having a continuously variable ratio transmission

    DOE Patents [OSTI]

    Frank, Andrew A. (1034 Hillside Ave., Madison, WI 53705)

    1984-01-01T23:59:59.000Z

    A control system and method for a power delivery system, such as in an automotive vehicle, having an engine coupled to a continuously variable ratio transmission (CVT). Totally independent control of engine and transmission enable the engine to precisely follow a desired operating characteristic, such as the ideal operating line for minimum fuel consumption. CVT ratio is controlled as a function of commanded power or torque and measured load, while engine fuel requirements (e.g., throttle position) are strictly a function of measured engine speed. Fuel requirements are therefore precisely adjusted in accordance with the ideal characteristic for any load placed on the engine.

  15. Practical method and device for enhancing pulse contrast ratio for lasers and electron accelerators

    DOE Patents [OSTI]

    Zhang, Shukui; Wilson, Guy

    2014-09-23T23:59:59.000Z

    An apparatus and method for enhancing pulse contrast ratios for drive lasers and electron accelerators. The invention comprises a mechanical dual-shutter system wherein the shutters are placed sequentially in series in a laser beam path. Each shutter of the dual shutter system has an individually operated trigger for opening and closing the shutter. As the triggers are operated individually, the delay between opening and closing first shutter and opening and closing the second shutter is variable providing for variable differential time windows and enhancement of pulse contrast ratio.

  16. Department of Energy's Pantex Plant Saves $10 Million in Energy Costs. Federal Energy Management Program (FEMP) ESPC Case Study Fact Sheet

    SciTech Connect (OSTI)

    Ward, C.

    2001-11-20T23:59:59.000Z

    This two-page case study describes how the U.S. Department of Energy's Pantex Plant in Amarillo, Texas, will save approximately $10 million in energy costs over the next 18 years, thanks to a DOE Super Energy Savings Performance Contract (Super ESPC) delivery order for energy efficiency improvements. The delivery order is the largest to date for a DOE facility. Primarily, the delivery order calls for a new, state-of-the-art energy management control system and a new water/steam piping system, which will be purchased and installed by the contracting energy services company (ESCO). The ESCO will then be repaid over the life of the contract out of the plant's resulting energy cost savings.

  17. Radioactive anomaly discrimination from spectral ratios

    DOE Patents [OSTI]

    Maniscalco, James; Sjoden, Glenn; Chapman, Mac Clements

    2013-08-20T23:59:59.000Z

    A method for discriminating a radioactive anomaly from naturally occurring radioactive materials includes detecting a first number of gamma photons having energies in a first range of energy values within a predetermined period of time and detecting a second number of gamma photons having energies in a second range of energy values within the predetermined period of time. The method further includes determining, in a controller, a ratio of the first number of gamma photons having energies in the first range and the second number of gamma photons having energies in the second range, and determining that a radioactive anomaly is present when the ratio exceeds a threshold value.

  18. Fission Product Ratios as Treaty Monitoring Discriminants

    SciTech Connect (OSTI)

    Miley, Harry S.; Bowyer, Ted W.; Greenwood, Lawrence R.; Arthur, Richard J.

    2008-05-15T23:59:59.000Z

    The International Monitoring System (IMS) of the Comprehensive Test Ban Treaty Organization (CTBTO) is currently under construction. The IMS is intended for monitoring of nuclear explosions. The radionuclide branch of the IMS monitors the atmosphere for short-lived radioisotopes indicative of a nuclear weapon test, and includes field collection and measurement stations, as well as laboratories to provide reanalysis of the most important samples and a quality control function. The Pacific Northwest National Laboratory in Richland, Washington hosts the United States IMS laboratory, with the designation “RL16.” Since acute reactor containment failures and chronic reactor leakage may also produce similar isotopes, it is tempting to compute ratios of detected isotopes to determine the relevance of an event to the treaty or agreement in question. In this paper we will note several shortcomings of simple isotopic ratios: (1) fractionation of different chemical species, (2) difficulty in comparing isotopes within a single element, (3) the effect of unknown decay times. While these shortcomings will be shown in the light of an aerosol sample, several of the problems extend to xenon isotopic ratios. The result of the difficulties listed above is that considerable human expertise will be required to convert a simple mathematical ratio into a criterion which will reliably categorize an event as ‘reactor’ or ‘weapon’.

  19. Viscosity to entropy ratio at extremality

    E-Print Network [OSTI]

    Sayan K. Chakrabarti; Sachin Jain; Sudipta Mukherji

    2010-01-19T23:59:59.000Z

    Assuming gauge theory realization at the boundary, we show that the viscosity to entropy ratio is 1/(4 pi) where the bulk is represented by a large class of extremal black holes in anti-de Sitter space. In particular, this class includes multiple R-charged black holes in various dimensions.

  20. Ratio method of measuring $w$ boson mass

    SciTech Connect (OSTI)

    Guo, Feng; /SUNY, Stony Brook

    2010-08-01T23:59:59.000Z

    This dissertation describes an alternative method of measuring the W boson mass in D0 experiment. Instead of extracting M{sub W} from the fitting of W {yields} e{nu} fast Monte Carlo simulations to W {yields} e{nu} data as in the standard method, we make the direct fit of transverse mass between W {yields} e{nu} data and Z {yields} ee data. One of the two electrons from Z boson is treated as a neutrino in the calculation of transverse mass. In ratio method, the best fitted scale factor corresponds to the ratio of W and Z boson mass (M{sub W}/M{sub Z}). Given the precisely measured Z boson mass, W mass is directly fitted from W {yields} e{nu} and Z {yields} ee data. This dissertation demonstrates that ratio method is a plausible method of measuring the W boson mass. With the 1 fb{sup -1} D0 Run IIa dataset, ratio method gives M{sub W} = 80435 {+-} 43(stat) {+-} 26(sys) MeV.

  1. Audit of the Department of Energy`s management of field contractor employees assigned to headquarters and other federal agencies

    SciTech Connect (OSTI)

    NONE

    1997-12-05T23:59:59.000Z

    The Department of Energy (Department) has spent at least $76 million annually for field contractor employee support in Headquarters and other Federal agencies. The employees were to provide technical expertise and experience critical to Department operations and programs. Overall, the audit was performed to determine if the Department was managing the use of field contractor employees assigned to Headquarters and other Federal agencies. Specifically, it was to determine whether the Department reviews and evaluates the costs for the use of contractor employees, is reimbursed for contractors working at other Federal agencies, and had implemented corrective actions proposed as the result of a prior audit report on this subject. The Department did not effectively manage the use of field contractor employees assigned to Headquarters and other Federal agencies. Specifically, the Department was unable to identify all contractor employees assigned to the Washington, DC area or determine the total cost of maintaining them; some employees were providing routine support and administrative services rather than unique program expertise; and several of the Department`s contractors had assigned their employees to work in other agencies without receiving full reimbursement for their services. In addition, the Department did not fully implement the corrective actions it agreed to in the prior audit report. Recommendations were made for the Deputy Secretary based on the audit findings. 3 tabs.

  2. Blowing Ratio Effects on Film Cooling Effectiveness

    E-Print Network [OSTI]

    Liu, Kuo-Chun

    2010-01-14T23:59:59.000Z

    cooling Rib turbulators Shaped internal cooling passage Trailing edge ejection Cooling air 3 Among the variety of film cooling hole designs, compound angle and shaped holes are generally considered in modern high pressure and high temperature gas turbine... ratio of 1.85. As compared to cylindrical hole, both shaped holes showed significant improved thermal protection of the surface downstream of the ejection location. Yu et al. [7] studied film cooling effectiveness and heat transfer distributions on a...

  3. Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

    SciTech Connect (OSTI)

    Stadler, Michael; Siddiqui, Afzal; Marnay, Chris; Aki, Hirohisa; Lai, Judy

    2009-08-10T23:59:59.000Z

    The U.S. Department of Energy has launched the commercial building initiative (CBI) in pursuit of its research goal of achieving zero-net-energy commercial buildings (ZNEB), i.e. ones that produce as much energy as they use. Its objective is to make these buildings marketable by 2025 such that they minimize their energy use through cutting-edge, energy-efficiency technologies and meet their remaining energy needs through on-site renewable energy generation. This paper examines how such buildings may be implemented within the context of a cost- or CO2-minimizing microgrid that is able to adopt and operate various technologies: photovoltaic modules (PV) and other on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and passive/demand-response technologies. A mixed-integer linear program (MILP) that has a multi-criteria objective function is used. The objective is minimization of a weighted average of the building's annual energy costs and CO2 emissions. The MILP's constraints ensure energy balance and capacity limits. In addition, constraining the building's energy consumed to equal its energy exports enables us to explore how energy sales and demand-response measures may enable compliance with the ZNEB objective. Using a commercial test site in northernCalifornia with existing tariff rates and technology data, we find that a ZNEB requires ample PV capacity installed to ensure electricity sales during the day. This is complemented by investment in energy-efficient combined heat and power (CHP) equipment, while occasional demand response shaves energy consumption. A large amount of storage is also adopted, which may be impractical. Nevertheless, it shows the nature of the solutions and costs necessary to achieve a ZNEB. Additionally, the ZNEB approach does not necessary lead to zero-carbon (ZC) buildings as is frequently argued. We also show a multi-objective frontier for the CA example, whichallows us to estimate the needed technologies and costs for achieving a ZC building or microgrid.

  4. Role of performance measures in reengineering U.S. Department of Energy`s management of environmental management programs

    SciTech Connect (OSTI)

    Murthy, K.S.; Harroun, W.P.

    1996-06-01T23:59:59.000Z

    The Rocky Flats Environmental Technology Site (Rocky Flats) contributed to America`s defense up to the end of the Cold War. It is one of several large US Department of Energy (DOE) nuclear industrial facilities, currently undergoing cleanup and closure. The Site was constructed in a sparsely populated area along the Rocky Mountain Foothills, near Denver, in 1952. In the 45 years since, Denver has grown to a major metropolitan area. Over 2 million people live within the Site`s 50-mile radius. The Site is directly upstream of water supplies that serve over 300,000 people. As a result, accelerated cleanup, consolidation, reuse, and closure of the Site are the current essentials. The Site has had three management and operating (M and O) contractors since inception. In keeping with the shift in the Site`s paradigm from one of weapon-parts production program to cleanup and closure project, DOE changed its contracting philosophy for the Site from the M and O type of contract to a Performance-based Incentive Fee Integrating Management contract (PBIF IMC). Doe selected the Site`s fourth contractor as an IMC contractor in July 1995. Kaiser-Hill Company L.L.C. was awarded the contract and assumed IMC responsibility for the Site on July 1, 1995. Integral to this contract is the establishment and implementation of a performance measures system. Performance measures are the bases for incentives that motivate the IMC and the subcontractors working at Rocky Flats. This paper provides an overview of Performance Measures system practiced at Rocky Flats from July 1995 to December 1995. Also described are the developments in reengineering during the July 1995--March 1996 interval.

  5. aspect ratio wings: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  6. aspect ratios numerical: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  7. aspect ratio microstructuring: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  8. aspect ratio: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  9. average aspect ratios: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  10. aspect ratio tori: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  11. aspect ratio ion: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  12. aspect ratio su-8: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  13. aspect ratio micro: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  14. aspect ratio domains: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  15. aspect ratio electrodes: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  16. aspect ratio plasmas: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  17. Potential Operation and Maintenance (O&M) Savings in the John Sealy South Building at UTMB

    E-Print Network [OSTI]

    Liu, M.; Athar, A.; Reddy, T. A.; Houcek, J. K.; Claridge, D. E.; Haberl, J. S.

    1993-01-01T23:59:59.000Z

    that annual savings of $174,000 can be realized by changing the EMCS control program and calibrating the temperature sensors of the cold deck. The majority of energy savings occur because the optimized operation schedule reduces reheat substantially. Our.... These systems pre-cool outdoor air before mixing with return air. Chilled water and steam are supplied by the central plant. An Energy Management and Control System (EMCS) was supposed to maintain the outdoor air cold deck temperature at 60 ?F and the main cold...

  18. Third-party/shared savings initiatives at DOE's government-owned/contractor-operated sites

    SciTech Connect (OSTI)

    Petrolati, V.P.

    1986-03-01T23:59:59.000Z

    To promote energy conservation at its government owned/contractor operated (GOCO) facilities, DOE implemented the In-house Energy Management (IHEM) Program. In early FY 1984, the IHEM program became interested in the concept of third-party financing as a potential supplement for its appropriated budget. The basic approach to this activity is discussed, including some of the initial concerns of third-party/shared savings financing at DOE facilities. The legal and procurement issues involved are discussed in detail. Planned initiatives are also discussed.

  19. Vehicle Technologies Office Merit Review 2014: High Compression Ratio Turbo Gasoline Engine Operation Using Alcohol Enhancement

    Broader source: Energy.gov [DOE]

    Presentation given by Massachusetts Institute of Technology at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high...

  20. "Table A15. Selected Energy Operating Ratios for Total Energy Consumption for"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocksa. AppliancesTotal" "(Data1.30. Total

  1. "Table A45. Selected Energy Operating Ratios for Total Energy Consumption"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocksa. AppliancesTotal"1" " (Estimates5. Selected

  2. "Table A46. Selected Energy Operating Ratios for Total Energy Consumption"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocksa. AppliancesTotal"1" " (Estimates5.

  3. "Table A47. Selected Energy Operating Ratios for Total Energy Consumption for"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocksa. AppliancesTotal"1" " (Estimates5.6. Total7.7.

  4. "Table A48. Selected Energy Operating Ratios for Total Energy Consumption for"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocksa. AppliancesTotal"1" " (Estimates5.6.

  5. "Table A50. Selected Energy Operating Ratios for Total Energy Consumption for"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocksa. AppliancesTotal"1" " (Estimates5.6.8.

  6. "Table A51. Selected Energy Operating Ratios for Total Energy Consumption for"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocksa. AppliancesTotal"1" " (Estimates5.6.8.1.

  7. "Table A8. Selected Energy Operating Ratios for Total Energy Consumption for"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocksa. AppliancesTotal"1" "Shell Storage Capacity

  8. air-fuel ratio: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    was performed to investigate the effects of air-fuel ratio, inlet boost pressure, hydrogen rich fuel reformate, and compression ratio on engine knock behavior. For each...

  9. Disentangling Dimension Six Operators through Di-Higgs Boson Production

    E-Print Network [OSTI]

    Pierce, Aaron; Thaler, Jesse; Wang, Lian-Tao

    2008-01-01T23:59:59.000Z

    Six Operators through Di-Higgs Boson Production Aaron Piercethe production rate and branching ratios of the Higgs boson.Here, we show how Higgs boson pair production can yield

  10. High load operation in a homogeneous charge compression ignition engine

    DOE Patents [OSTI]

    Duffy, Kevin P. (Metamora, IL); Kieser, Andrew J. (Morton, IL); Liechty, Michael P. (Chillicothe, IL); Hardy, William L. (Peoria, IL); Rodman, Anthony (Chillicothe, IL); Hergart, Carl-Anders (Peoria, IL)

    2008-12-23T23:59:59.000Z

    A homogeneous charge compression ignition engine is set up by first identifying combinations of compression ratio and exhaust gas percentages for each speed and load across the engines operating range. These identified ratios and exhaust gas percentages can then be converted into geometric compression ratio controller settings and exhaust gas recirculation rate controller settings that are mapped against speed and load, and made available to the electronic

  11. Case studies of energy information systems and related technology: Operational practices, costs, and benefits

    SciTech Connect (OSTI)

    Motegi, Naoya; Piette, Mary Ann; Kinney, Satkartar; Dewey, Jim

    2003-09-02T23:59:59.000Z

    Energy Information Systems (EIS), which can monitor and analyze building energy consumption and related data throughout the Internet, have been increasing in use over the last decade. Though EIS developers describe the capabilities, costs, and benefits of EIS, many of these descriptions are idealized and often insufficient for potential users to evaluate cost, benefit and operational usefulness. LBNL has conducted a series of case studies of existing EIS and related technology installations. This study explored the following questions: (1) How is the EIS used in day-to-day operation? (2) What are the costs and benefits of an EIS? (3) Where do the energy savings come from? This paper reviews the process of these technologies from installation through energy management practice. The study is based on interviews with operators and energy managers who use EIS. Analysis of energy data trended by EIS and utility bills was also conducted to measure the benefit. This paper explores common uses and findings to identify energy savings attributable to EIS, and discusses non-energy benefits as well. This paper also addresses technologies related to EIS that have been demonstrated and evaluated by LBNL.

  12. REAL TIME SYSTEM OPERATIONS 2006-2007

    E-Print Network [OSTI]

    Eto, Joseph H.

    2008-01-01T23:59:59.000Z

    and Data Acquisition (SCADA) data and off?line model?based California ISO’s current SCADA/Energy Management System  (Monitoring System  RTSO  RTVSA  SCADA/EMS  SCE  SDG&E  TRP 

  13. Implications of Fast Reactor Transuranic Conversion Ratio

    SciTech Connect (OSTI)

    Steven J. Piet; Edward A. Hoffman; Samuel E. Bays

    2010-11-01T23:59:59.000Z

    Theoretically, the transuranic conversion ratio (CR), i.e. the transuranic production divided by transuranic destruction, in a fast reactor can range from near zero to about 1.9, which is the average neutron yield from Pu239 minus 1. In practice, the possible range will be somewhat less. We have studied the implications of transuranic conversion ratio of 0.0 to 1.7 using the fresh and discharge fuel compositions calculated elsewhere. The corresponding fissile breeding ratio ranges from 0.2 to 1.6. The cases below CR=1 (“burners”) do not have blankets; the cases above CR=1 (“breeders”) have breeding blankets. The burnup was allowed to float while holding the maximum fluence to the cladding constant. We graph the fuel burnup and composition change. As a function of transuranic conversion ratio, we calculate and graph the heat, gamma, and neutron emission of fresh fuel; whether the material is “attractive” for direct weapon use using published criteria; the uranium utilization and rate of consumption of natural uranium; and the long-term radiotoxicity after fuel discharge. For context, other cases and analyses are included, primarily once-through light water reactor (LWR) uranium oxide fuel at 51 MWth-day/kg-iHM burnup (UOX-51). For CR<1, the heat, gamma, and neutron emission increase as material is recycled. The uranium utilization is at or below 1%, just as it is in thermal reactors as both types of reactors require continuing fissile support. For CR>1, heat, gamma, and neutron emission decrease with recycling. The uranium utilization exceeds 1%, especially as all the transuranic elements are recycled. exceeds 1%, especially as all the transuranic elements are recycled. At the system equilibrium, heat and gamma vary by somewhat over an order of magnitude as a function of CR. Isotopes that dominate heat and gamma emission are scattered throughout the actinide chain, so the modest impact of CR is unsurprising. Neutron emitters are preferentially found among the higher actinides, so the neutron emission varies much stronger with CR, about three orders of magnitude.

  14. High aspect ratio, remote controlled pumping assembly

    DOE Patents [OSTI]

    Brown, Steve B. (Livermore, CA); Milanovich, Fred P. (Lafayette, CA)

    1995-01-01T23:59:59.000Z

    A miniature dual syringe-type pump assembly which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor.

  15. Energy Balance Bowen Ratio Station (EBBR) Handbook

    SciTech Connect (OSTI)

    Cook, DR

    2011-02-23T23:59:59.000Z

    The energy balance Bowen ratio (EBBR) system produces 30-minute estimates of the vertical fluxes of sensible and latent heat at the local surface. Flux estimates are calculated from observations of net radiation, soil surface heat flux, and the vertical gradients of temperature and relative humidity (RH). Meteorological data collected by the EBBR are used to calculate bulk aerodynamic fluxes, which are used in the Bulk Aerodynamic Technique (BA) EBBR value-added product (VAP) to replace sunrise and sunset spikes in the flux data. A unique aspect of the system is the automatic exchange mechanism (AEM), which helps to reduce errors from instrument offset drift.

  16. Meteorological Effects on Air/Fuel Ratio

    E-Print Network [OSTI]

    Ferri, J. L.

    1984-01-01T23:59:59.000Z

    ) where subscript 1 indicates at condition 1 and subsc 1pt 2 Indicates at condition 2. Solving for E gives 2 100. (E . 13) Example 1 A furnace with a pressure type ratio control sys~em is calibrated at 10% excess air with 30 of air. If the air... of ... 30 of ... 460? 590 oR Substituting in Equation 13 and solving for E gives 2 E = (100 ... 10) (:;~)II, - 100 = 3.3% excess ir. 2 If the furnace had been calibrated to 10% excess air with iOO of air, the % excess air with 30 of air would bJI 590 II...

  17. High aspect ratio, remote controlled pumping assembly

    DOE Patents [OSTI]

    Brown, S.B.; Milanovich, F.P.

    1995-11-14T23:59:59.000Z

    A miniature dual syringe-type pump assembly is described which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor. 4 figs.

  18. Operator Objective Function Guidance for a Real-time Unmanned Vehicle Scheduling Algorithm

    E-Print Network [OSTI]

    Clare, A.S.

    Advances in autonomy have made it possible to invert the typical operator-to-unmanned-vehicle ratio so that asingle operator can now control multiple heterogeneous unmanned vehicles. Algorithms used in unmanned-vehicle ...

  19. Ratios of heavy hadron semileptonic decay rates

    E-Print Network [OSTI]

    Michael Gronau; Jonathan L. Rosner

    2010-12-27T23:59:59.000Z

    Ratios of charmed meson and baryon semileptonic decay rates appear to be satisfactorily described by considering only the lowest-lying (S-wave) hadronic final states and assuming the kinematic factor describing phase space suppression is the same as that for free quarks. For example, the rate for $D_s$ semileptonic decay is known to be $(17.0 \\pm 5.3)%$ lower than those for $D^0$ or $D^+$, and the model accounts for this difference. When applied to hadrons containing $b$ quarks, this method implies that the $B_s$ semileptonic decay rate is about 1% higher than that of the nonstrange $B$ mesons. This small difference thus suggests surprisingly good local quark-hadron duality for $B$ semileptonic decays, complementing the expectation based on inclusive quark-hadron duality that these differences in rates should not exceed a few tenths of a percent. For $\\Lambda_b$ semileptonic decay, however, the inclusive rate is predicted to be about 13% greater than that of the nonstrange $B$ mesons. This value, representing a considerable departure from a calculation using a heavy quark expansion, is close to the corresponding experimental ratio $\\Gamma(\\Lambda_b)/ \\bar \\Gamma(B) = 1.13 \\pm 0.03$ of total decay rates.

  20. Flexible Conversion Ratio Fast Reactor Systems Evaluation

    SciTech Connect (OSTI)

    Neil Todreas; Pavel Hejzlar

    2008-06-30T23:59:59.000Z

    Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores reated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcme the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better themal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor.

  1. Operations and compositions in transrecursive operators

    SciTech Connect (OSTI)

    Burgin, M.S.; Borodyanskii, Yu.M.

    1995-03-01T23:59:59.000Z

    The present study is a continuation of a study focusing on introduction and analysis of operations on transrecursive operators, which are similar to the operators considered in the theory of algorithms. Such operations may be standard product of algorithms) or special ({alpha}-disjunction and {alpha}-iteration. In some respects, these operations in the class of transrecursive operators are similar to their traditional analogs. In other respects, however, they are essentially different. For instance, they may have different types and modes. Specific features of operations on transrecursive operators are attributable to explicit omission of some restrictions on their construction compared with the construction of algorithms. The standard approaches to mathematical modeling of the concept of algorithm assume a number of essential restrictions. Specifically, they assume finiteness of (1) the input data arriving during a finite time interval; (2) the list of rules underlying the operations of the algorithm; (3) the transformations executed by a single operation; (4) the description of each rule; (5) the time to execute one operation; (6) the time to execute one operation; (7) the number of cycles that the algorithm executes in order to realize the mapping. In application to Turing machines, these restrictions imply finiteness of the initial word, finiteness of the command table of the read head, and ultimate stopping when the result is obtained after finitely many steps. Various classes of transrecursive operators are constructed by dropping various combinations of the {open_quotes}finiteness{close_quotes} restrictions. Two classes of transrecursive operators - the limit (inductive) Turing machines and transalgorithms - have been obtained by dropping respectively the assumption of finiteness of the number of execution cycles and the assumption of finiteness of the list of rules.

  2. An Advanced Framework for Improving Situational Awareness in Electric Power Grid Operation

    SciTech Connect (OSTI)

    Chen, Yousu; Huang, Zhenyu; Zhou, Ning

    2011-10-17T23:59:59.000Z

    With the deployment of new smart grid technologies and the penetration of renewable energy in power systems, significant uncertainty and variability is being introduced into power grid operation. Traditionally, the Energy Management System (EMS) operates the power grid in a deterministic mode, and thus will not be sufficient for the future control center in a stochastic environment with faster dynamics. One of the main challenges is to improve situational awareness. This paper reviews the current status of power grid operation and presents a vision of improving wide-area situational awareness for a future control center. An advanced framework, consisting of parallel state estimation, state prediction, parallel contingency selection, parallel contingency analysis, and advanced visual analytics, is proposed to provide capabilities needed for better decision support by utilizing high performance computing (HPC) techniques and advanced visual analytic techniques. Research results are presented to support the proposed vision and framework.

  3. Operating Permits (New Jersey)

    Broader source: Energy.gov [DOE]

    The owner or operator of a facility subject to this article shall obtain and maintain an operating permit for the facility. The owner or operator of a facility subject to this article shall ensure...

  4. Cogeneration Operational Issues

    E-Print Network [OSTI]

    Williams, M.

    operations. Other operational issues also include utility transmission planning, generation planning and fuel mix decisions. All of these operational problems have an impact on the ratepayer in regard to quality of electric service and future rates. Both...

  5. Heat Transfer Operators Associated with Quantum Operations

    E-Print Network [OSTI]

    Ç. Aksak; S. Turgut

    2011-04-14T23:59:59.000Z

    Any quantum operation applied on a physical system is performed as a unitary transformation on a larger extended system. If the extension used is a heat bath in thermal equilibrium, the concomitant change in the state of the bath necessarily implies a heat exchange with it. The dependence of the average heat transferred to the bath on the initial state of the system can then be found from the expectation value of a hermitian operator, which is named as the heat transfer operator (HTO). The purpose of this article is the investigation of the relation between the HTOs and the associated quantum operations. Since, any given quantum operation on a system can be realized by different baths and unitaries, many different HTOs are possible for each quantum operation. On the other hand, there are also strong restrictions on the HTOs which arise from the unitarity of the transformations. The most important of these is the Landauer erasure principle. This article is concerned with the question of finding a complete set of restrictions on the HTOs that are associated with a given quantum operation. An answer to this question has been found only for a subset of quantum operations. For erasure operations, these characterizations are equivalent to the generalized Landauer erasure principle. For the case of generic quantum operations however, it appears that the HTOs obey further restrictions which cannot be obtained from the entropic restrictions of the generalized Landauer erasure principle.

  6. Building Operator Certification

    E-Print Network [OSTI]

    Lilley, D.

    2013-01-01T23:59:59.000Z

    Building Operator Certification Energy Efficiency through Operator Training CATEE December 18, 2013 – San Antonio, TX Dennis Lilley, CEM, PMP ESL-KT-13-12-49 CATEE 2013: Clean Air Through Energy Efficiency Conference, San Antonio, Texas Dec. 16...-18 Building Operator Certification Energy Efficiency through Operator Training What is Building Operator Certification? Industry-recognized credential in energy efficient building operation practices Created with 100 industry experts Launched in 1996 9...

  7. Abundance ratios in hierarchical galaxy formation

    E-Print Network [OSTI]

    D. Thomas

    1999-01-18T23:59:59.000Z

    The chemical enrichment and stellar abundance ratios of galaxies which form in a hierarchical clustering scheme are calculated. For this purpose I adopt the star formation histories (SFH) as they are delivered by semi-analytic models in Kauffmann (1996}. It turns out that the average SFH of cluster ellipticals does not yield globally alpha-enhanced stellar populations. The star burst that occurs when the elliptical forms in the major merger plays therefore a crucial role in producing alpha-enhancement. Only under the assumption that the IMF is significantly flattened with respect to the Salpeter value during the burst, a Mg/Fe overabundant population can be obtained. In particular for the interpretation of radial gradients in metallicity and alpha-enhancement, the mixing of global and burst populations are of great importance. The model predicts bright field galaxies to be less alpha-enhanced than their counterparts in clusters.

  8. Operation and Maintenance

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Operations and Maintenance Operations OASIS: WALC-DSW (Note: this site is not hosted by Western and requires a digital certificate and login for full access.) Contact Information...

  9. Operations Information for Studies

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Operations Information for Studies This page contains historical information about hydropower operations. Reclamation UC Region 24-Month Studies FY2009 Load Information (pdf) SLIP...

  10. Operations Cost Allocation Project

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Operations Consolidation Project Operations Consolidation Project (OCP) Cost Allocation Presentation - September 20, 2011 OCP Cost Allocation Customer Presentation List of Acronyms...

  11. Operations Research Analyst

    Broader source: Energy.gov [DOE]

    The incumbent in this position will serve as an Operations Research Analyst in the Generation Scheduling (PGS). The Operations Research Analyst is responsible for analytical work that involves...

  12. Analysis on burnup step effect for evaluating reactor criticality and fuel breeding ratio

    SciTech Connect (OSTI)

    Saputra, Geby; Purnama, Aditya Rizki; Permana, Sidik [Nuclear Physics and Biophysics Research Division, Physics Department, Institut Teknologi Bandung (Indonesia); Suzuki, Mitsutoshi [Department of Science and Technology for Nuclear Material Management (STNM), Japan Atomic Energy Agency (JAEA) (Japan)

    2014-09-30T23:59:59.000Z

    Criticality condition of the reactors is one of the important factors for evaluating reactor operation and nuclear fuel breeding ratio is another factor to show nuclear fuel sustainability. This study analyzes the effect of burnup steps and cycle operation step for evaluating the criticality condition of the reactor as well as the performance of nuclear fuel breeding or breeding ratio (BR). Burnup step is performed based on a day step analysis which is varied from 10 days up to 800 days and for cycle operation from 1 cycle up to 8 cycles reactor operations. In addition, calculation efficiency based on the variation of computer processors to run the analysis in term of time (time efficiency in the calculation) have been also investigated. Optimization method for reactor design analysis which is used a large fast breeder reactor type as a reference case was performed by adopting an established reactor design code of JOINT-FR. The results show a criticality condition becomes higher for smaller burnup step (day) and for breeding ratio becomes less for smaller burnup step (day). Some nuclides contribute to make better criticality when smaller burnup step due to individul nuclide half-live. Calculation time for different burnup step shows a correlation with the time consuming requirement for more details step calculation, although the consuming time is not directly equivalent with the how many time the burnup time step is divided.

  13. Energy Information Handbook: Applications for Energy-Efficient Building Operations

    SciTech Connect (OSTI)

    New Buildings Institute; Pacific Northwest National Laboratory; Granderson, Jessica; Piette, Mary Ann; Rosenblum, Ben; Hu, Lily; Harris, Daniel; Mathew, Paul; Price, Phillip; Bell, Geoffrey; Katipamula, Srinivas; Brambley, Michael

    2011-10-01T23:59:59.000Z

    This handbook will give you the information you need to plan an energy-management strategy that works for your building, making it more energy efficient.

  14. S. 417: This Act may be cited as the Federal Energy Management Amendments Act of 1991, introduced in the Senate of the United States, One Hundred Second Congress, First Session, February 7, 1991

    SciTech Connect (OSTI)

    Not Available

    1991-01-01T23:59:59.000Z

    This bill would establish energy conservation and clean energy requirements for Federal buildings. The goals are to increase the energy efficiency of existing technologies; ensure that Federal agencies adopt cost-effective energy conservation measures; encourage investment in clean alternative energy resources (including fuel cells, solar, wind); and encourage investment in energy efficient equipment and technology. The bill describes energy management goals; fuel cells joint ventures; and a study on life cycle cost methods and procedures.

  15. Energy manager design for microgrids

    E-Print Network [OSTI]

    Firestone, Ryan; Marnay, Chris

    2005-01-01T23:59:59.000Z

    Predictive Algorithms for Microturbine Performance for BCHPnatural gas engine, and a microturbine is xv Energy Managera reciprocating engine, a microturbine, photovoltaics, or a

  16. Oklahoma Industrial Energy Management Program 

    E-Print Network [OSTI]

    Estes, C. B.; Turner, W. C.

    1980-01-01T23:59:59.000Z

    usage continues to rise. With this informa tion, Oklahoma embarked upon a program to help indus try (particularly small to medium sized ones) meet the challenge. Program Objectives The primary objective of the program can be stated simply as: "To... for the country and necessary for her to be competitive in the International marketplace. PROGRAM DESCRIPTION The first step was to develop a symbol that year tenure of the.program. The conferences have concentrated on the industrialized areas of Tulsa...

  17. Energy Management and Information Systems

    E-Print Network [OSTI]

    Conraud, J.

    2013-01-01T23:59:59.000Z

    ?maintain?new?assets,?pay?for? software?fees,?coordinating?activities,? etc. ? Hardware?and?software?doesn?t?forgo? the?need?for?brain?power lessons?learned On?the?Roadmap ? Finish?implementing?revised? HVAC?schedules ? Address?occupancy?detection,? ventilation...

  18. Energy Management Through Innovative Rates

    E-Print Network [OSTI]

    Williams, M. L.

    1982-01-01T23:59:59.000Z

    of energy efficiency in the industrial sector and specific rate design alternatives for doing so....

  19. Energy Management at Deere & Company

    E-Print Network [OSTI]

    Boyd, M. P.

    1979-01-01T23:59:59.000Z

    that has become increasingly complex. Fuel availability is a fluctuating phenomenon. Technology to enable energy conservation and to supply efficient alternate non-depleting sources is complex. Government intervention is becoming increasingly pervasive...

  20. Energy Management in Olefins Units 

    E-Print Network [OSTI]

    Wells, T. A.

    1982-01-01T23:59:59.000Z

    to the point where waste heat from pyrolysis generates more than enough steam to power the olefins unit recovery section. Furthermore, incorporating gas turbine driven electrical generators or process compressors adds to the utility export potential of the unit...