Powered by Deep Web Technologies
Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Experimental performance analysis of a solar assisted ground source heat pump system under different heating operation modes  

Science Journals Connector (OSTI)

Abstract This paper presents an experimental study on the influence of operation modes on the heating performance of a solar assisted ground source heat pump system (SAGSHPS). Through experiments conducted in January, the characteristics of the SAGSHPS were investigated under different heating operation modes. The results indicate that the solar thermal could be used to accelerate the soil recovery when the heat pump unit is turned off, but the duration of solar use to recharge boreholes should be optimized according to the water temperature in the solar heat storage water tank to avoid unnecessary power consumption of the circulation pump. In addition, the solar heat storage water tank is beneficial for the stable operation of the SAGSHPS. The volumetric flow rate in the water tank has a significant impact on the electricity consumption of the SAGSHPS. From comprehensive analysis of the integral effect of the SAGSHPS under different modes, the mode in which the water tank is connected with the ground heat exchangers (GHES) in series is the recommended mode for the SAGSHPS in the coldest month in Dalian.

Lanhua Dai; Sufen Li; Lin DuanMu; Xiangli Li; Yan Shang; Ming Dong

2015-01-01T23:59:59.000Z

2

Measured Performance and Analysis of Ground Source Heat Pumps for Space Conditioning and for Water Heating in a Low-Energy Test House Operated under Simulated Occupancy Conditions  

SciTech Connect (OSTI)

In this paper we present measured performance and efficiency metrics of Ground Source Heat Pumps (GSHPs) for space conditioning and for water heating connected to a horizontal ground heat exchanger (GHX) loop. The units were installed in a 345m2 (3700ft2) high-efficiency test house built with structural insulated panels (SIPs), operated under simulated occupancy conditions, and located in Oak Ridge, Tennessee (USA) in US Climate Zone 4 . The paper describes distinctive features of the building envelope, ground loop, and equipment, and provides detailed monthly performance of the GSHP system. Space conditioning needs of the house were completely satisfied by a nominal 2-ton (7.0 kW) water-to-air GSHP (WA-GSHP) unit with almost no auxiliary heat usage. Recommendations for further improvement through engineering design changes are identified. The comprehensive set of data and analyses demonstrate the feasibility and practicality of GSHPs in residential applications and their potential to help achieve source energy and greenhouse gas emission reduction targets set under the IECC 2012 Standard.

Ally, Moonis Raza [ORNL] [ORNL; Munk, Jeffrey D [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL; Gehl, Anthony C [ORNL] [ORNL

2012-01-01T23:59:59.000Z

3

Exergy Analysis and Operational Efficiency of a Horizontal Ground Source Heat Pump System Operated in a Low-Energy Test House under Simulated Occupancy Conditions  

SciTech Connect (OSTI)

This paper presents data, analyses, measures of performance, and conclusions for a ground-source heat pump (GSHP) providing space conditioning to a 345m2 house whose envelope is made of structural insulated panels (SIP). The entire thermal load of this SIP house with RSI-3.7 (RUS-21) walls, triple pane windows with a U-factor of 1.64 W/m2 K (0.29 Btu/h ft2 oF) and solar heat gain coefficient (SHGC) of 0.25, a roof assembly with overall thermal resistance of about RSI-8.8 (RUS-50) and low leakage rates of 0.74 ACH at 50Pa was satisfied with a 2.16-Ton (7.56 kW) GSHP unit consuming negligible (9.83kWh) auxiliary heat during peak winter season. The highest and lowest heating COP achieved was 4.90 (October) and 3.44 (February), respectively. The highest and lowest cooling COP achieved was 6.09 (April) and 3.88 (August). These COPs are calculated on the basis of the total power input (including duct, ground loop, and control power losses ). The second Law (Exergy) analysis provides deep insight into how systemic inefficiencies are distributed among the various GSHP components. Opportunities for design and further performance improvements are identified. Through Exergy analysis we provide a true measure of how closely actual performance approaches the ideal, and it unequivocally identifies, better than energy analysis does, the sources and causes of lost work, the root cause of system inefficiencies.

Ally, Moonis Raza [ORNL; Baxter, Van D [ORNL; Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL

2012-01-01T23:59:59.000Z

4

Ground Gravity Survey At Under Steamboat Springs Area (Warpinski...  

Open Energy Info (EERE)

Area (Warpinski, Et Al., 2004) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Gravity Survey At Under Steamboat Springs Area (Warpinski,...

5

Apparatus and method for grounding compressed fuel fueling operator  

DOE Patents [OSTI]

A safety system for grounding an operator at a fueling station prior to removing a fuel fill nozzle from a fuel tank upon completion of a fuel filling operation is provided which includes a fuel tank port in communication with the fuel tank for receiving and retaining the nozzle during the fuel filling operation and a grounding device adjacent to the fuel tank port which includes a grounding switch having a contact member that receives physical contact by the operator and where physical contact of the contact member activates the grounding switch. A releasable interlock is included that provides a lock position wherein the nozzle is locked into the port upon insertion of the nozzle into the port and a release position wherein the nozzle is releasable from the port upon completion of the fuel filling operation and after physical contact of the contact member is accomplished.

Cohen, Joseph Perry (Bethlehem, PA); Farese, David John (Riegelsville, PA); Xu, Jianguo (Wrightstown, PA)

2002-06-11T23:59:59.000Z

6

The MER/CIP Portal for Ground Operations Louise Chan*  

E-Print Network [OSTI]

The MER/CIP Portal for Ground Operations Louise Chan* Sanjay Desai* Matthew D'Ortenzio Robert E Portal We developed the Mars Exploration Rover/Collaborative Information Portal (MER/CIP) to facilitate MER operations. MER/CIP provides a cen- tralized, one-stop delivery platform integrating science

Filman, Robert E.

7

Aircraft energy conservation during airport ground operations. Final report  

SciTech Connect (OSTI)

This study identifies and assesses potential fuel conservation options which are available for use during ground operations at Dulles International (IAD) and Washington National (DCA) airports. The study also identifies and analyzes ground operations fuel savings options which have been considered and/or implemented by the various airlines operating at IAD and/or DCA since 1971. In addition, an evaluation of computer models which could be used for analyzing these fuel conservation options at other airports is included. The impact of socio/economic factors such as safety, environment, limitation on expansion and restrictions on accommodating forecast activity at DCA and IAD were considered during the analysis of each option.

Bauchspies, J.S.; Costello, F.A.; Felder, J.; Hilliard, H.; Thompson, J.K.

1982-03-01T23:59:59.000Z

8

Ground-water contribution to dose from past Hanford Operations  

SciTech Connect (OSTI)

The Hanford Environmental Dose Reconstruction (HEDR) Project is being conducted to estimate radiation doses that populations and individuals could have received from Hanford Site operations from 1944 to the present. Four possible pathways by which radionuclides migrating in ground water on the Hanford Site could have reached the public have been identified: (1) through contaminated ground water migrating to the Columbia River; (2) through wells on or adjacent to the Hanford Site; (3) through wells next to the Columbia River downstream of Hanford that draw some or all of their water from the river (riparian wells); and (4) through atmospheric deposition resulting in contamination of a small watershed that, in turn, results in contamination of a shallow well or spring by transport in the ground water. These four pathways make up the ground-water pathway,'' which is the subject of this study. Assessment of the ground-water pathway was performed by (1) reviewing the existing extensive literature on ground water and ground-water monitoring at Hanford and (2) performing calculations to estimate radionuclide concentrations where no monitoring data were collected. Radiation doses that would result from exposure to these radionuclides were calculated.

Freshley, M.D.; Thorne, P.D.

1992-08-01T23:59:59.000Z

9

GROUND-WATER CONTRIBUTION TO DOSE FROM PAST HANFORD OPERATIONS  

SciTech Connect (OSTI)

The Hanford Environmental Dose Reconstruction (HEOR) Project is being conducted to estimate radiation doses that populations and individuals could have received from Hanford Site operations from 1944 to the present. Four possible pathways by which radionuclides originating in ground water on the Hanford Site could have reached the public have been identified: 1) through contaminated ground water migrating to the Columbia River; 2) through wells on or adjacent to the Hanford Site; 3) through wells that draw some or all of their water from the Columbia River (riparian wells); and 4) through atmospheric deposition resulting in the contamination of a small watershed that, in turn, results in contamination of a shallow well or spring. These four pathways make up the "ground-water pathway ," which is the subject of this study. The objective of the study was to assess the extent to which the groundwater pathway contributed to radiation doses that populations or individuals may have received from past operations at Hanford. The assessment presented in this report was performed by 1) reviewing the extensive ?literature on ground water and ground-water monitoring at Hanford and 2) performing simple calculations to estimate radionuclide concentrations in ground water and the Columbia River resulting from ground-water discharge. Radiation doses that would result from exposure to this ground water and surface water were calculated. The study conclusion is that the ground-water pathways did not contribute significantly to dose. Compared with background radiation in the TriCities {300 mrem/yr), estimated doses are small: 0.02 mrem/yr effective dose equivalent from discharge of contaminated ground water to the Columbia River; 1 mrem/yr effective dose equivalent from Hanford Site wells; 11 mrem/yr effective dose equivalent from riparian wells; and 1 mrem/yr effective dose equivalent from the watershed. Because the estimated doses are so small, the recommendation is that further work on the ground-water pathway be limited to tracking ongoing ground-water studies at the Hanford Site.

Freshley, M. D.; Thorne, P. D.

1992-01-01T23:59:59.000Z

10

Analysis and Modeling of Ground Operations at Hub Airports  

E-Print Network [OSTI]

constraint in the departure process at busy airports like Boston Logan International airport. For example1 Analysis and Modeling of Ground Operations at Hub Airports Kari Andersson1 , Francis Carr2 , Eric Feron3 and William D. Hall4 Abstract: Building simple and accurate models of hub airports can

Feron, Eric

11

On Aerodynamic Optimization Under a Range of Operating Conditions  

E-Print Network [OSTI]

On Aerodynamic Optimization Under a Range of Operating Conditions David W. Zingg, and Samy Elias In aerodynamic design, good performance is generally required under a range of oper- ating conditions, including aerodynamic shape optimization.1­6 The designer specifies an objective, operating conditions, constraints

Zingg, David W.

12

Ground Gravity Survey At Under Steamboat Springs Area (Warpinski, Et Al.,  

Open Energy Info (EERE)

Ground Gravity Survey At Under Steamboat Springs Area (Warpinski, Et Al., Ground Gravity Survey At Under Steamboat Springs Area (Warpinski, Et Al., 2002) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Gravity Survey At Under Steamboat Springs Area (Warpinski, Et Al., 2002) Exploration Activity Details Location Under Steamboat Springs Area Exploration Technique Ground Gravity Survey Activity Date Usefulness useful DOE-funding Unknown Notes This project consisted of (1) a 3-D surface seismic survey conducted in the fall of 2000, (2) a micro-seismic survey run from November 2000 to April 200 1, and (3) a gravity survey conducted in April and May 2001. The 3-D surface seismic data are still being processed at this time, but initial results indicate that there are two major lineations of high velocity

13

DOE Orders Mirant Power Plant to Operate Under Limited Circumstances |  

Broader source: Energy.gov (indexed) [DOE]

Orders Mirant Power Plant to Operate Under Limited Orders Mirant Power Plant to Operate Under Limited Circumstances DOE Orders Mirant Power Plant to Operate Under Limited Circumstances Docket No. EO-05-01. Order No. 202-05-3: Secretary of Energy Samuel W. Bodman today issued an order requiring Mirant Corporation's Potomac River Generating Station in Alexandria, Virginia (Mirant) to immediately resume limited operation. The order will help provide electric reliability for Washington, D.C., and will do so at the lowest reasonable impact to the environment. DOE Orders Mirant Power Plant to Operate Under Limited Circumstances More Documents & Publications Comments on Department of Energy's Emergency Order To Resume Limited Operation at Mirant's Potomac River Generating Station and Proposed Mirant Compliance Plan

14

Ground-water contribution to dose from past Hanford Operations. Hanford Environmental Dose Reconstruction Project  

SciTech Connect (OSTI)

The Hanford Environmental Dose Reconstruction (HEDR) Project is being conducted to estimate radiation doses that populations and individuals could have received from Hanford Site operations from 1944 to the present. Four possible pathways by which radionuclides migrating in ground water on the Hanford Site could have reached the public have been identified: (1) through contaminated ground water migrating to the Columbia River; (2) through wells on or adjacent to the Hanford Site; (3) through wells next to the Columbia River downstream of Hanford that draw some or all of their water from the river (riparian wells); and (4) through atmospheric deposition resulting in contamination of a small watershed that, in turn, results in contamination of a shallow well or spring by transport in the ground water. These four pathways make up the ``ground-water pathway,`` which is the subject of this study. Assessment of the ground-water pathway was performed by (1) reviewing the existing extensive literature on ground water and ground-water monitoring at Hanford and (2) performing calculations to estimate radionuclide concentrations where no monitoring data were collected. Radiation doses that would result from exposure to these radionuclides were calculated.

Freshley, M.D.; Thorne, P.D.

1992-08-01T23:59:59.000Z

15

1997 annual ground control operating plan for the Waste Isolation Pilot Plant  

SciTech Connect (OSTI)

This plan presents background information and a working guide to assist Mine Operations and Engineering in developing strategies for addressing ground control issues at the Waste Isolation Pilot Plant (WIPP). With the anticipated receipt of waste in late 1997, this document provides additional detail to Panel 1 activities and options. The plan also serves as a foundation document for development and revision of the annual long-term ground control plan. Section 2.0 documents the current status of all underground excavations with respect to location, geology, geometry, age, ground support, operational use, projected life, and physical conditions. Section 3.0 presents the methods used to evaluate ground conditions, including visual observations of the roof, ribs, and floor, inspection of observation holes, and review of instrumentation data. Section 4.0 lists several ground support options and specific applications of each. Section 5.0 discusses remedial ground control measures that have been implemented to date. Section 6.0 presents projections and recommendations for ground control actions based on the information in Sections 2.0 through 5.0 of this plan and on a rating of the critical nature of each specific area. Section 7.0 presents a summary statement, and Section 8.0 includes references. Appendix A provides an overview and critique of ground control systems that have been, or may be, used at the site. Because of the dynamic nature of the underground openings and associated geotechnical activities, this plan will be revised as additional data are incorporated.

NONE

1997-02-01T23:59:59.000Z

16

Large mobile mining equipment operating on soft ground T.G. Joseph  

E-Print Network [OSTI]

1 Large mobile mining equipment operating on soft ground T.G. Joseph School of Mining & Petroleum. The toll on large mobile mining equipment such as > 327 tonne capacity haulers and > 46 m3 electric for large mobile units, a discussion on the extension of the process to shovel undercarriage and carbody

Joseph, Tim Grain

17

Aerodynamic Optimization Under a Range of Operating Conditions  

E-Print Network [OSTI]

Aerodynamic Optimization Under a Range of Operating Conditions David W. Zingg and Samy Elias. This can be achieved through multipoint optimization. The desired performance objective and operating conditions must be speci ed, and the resulting optimization problem must be solved in such a manner

Zingg, David W.

18

DOE Orders Mirant Power Plant to Operate Under Limited Circumstances |  

Broader source: Energy.gov (indexed) [DOE]

DOE Orders Mirant Power Plant to Operate Under Limited DOE Orders Mirant Power Plant to Operate Under Limited Circumstances DOE Orders Mirant Power Plant to Operate Under Limited Circumstances December 20, 2005 - 11:44am Addthis DOE finds emergency; determines plant will help electric reliability WASHINGTON, D.C. - Secretary of Energy Samuel W. Bodman today issued an order requiring Mirant Corporation's Potomac River Generating Station in Alexandria, Virginia (Mirant) to immediately resume limited operation. The order will help provide electric reliability for Washington, D.C., and will do so at the lowest reasonable impact to the environment. "After weighing all of the information, I believe an emergency situation exists, and that issuance of this order is in the public interest. This order will provide the level of electricity reliability necessary to keep

19

DOE Orders Mirant Power Plant to Operate Under Limited Circumstances |  

Broader source: Energy.gov (indexed) [DOE]

Orders Mirant Power Plant to Operate Under Limited Orders Mirant Power Plant to Operate Under Limited Circumstances DOE Orders Mirant Power Plant to Operate Under Limited Circumstances December 20, 2005 - 11:44am Addthis DOE finds emergency; determines plant will help electric reliability WASHINGTON, D.C. - Secretary of Energy Samuel W. Bodman today issued an order requiring Mirant Corporation's Potomac River Generating Station in Alexandria, Virginia (Mirant) to immediately resume limited operation. The order will help provide electric reliability for Washington, D.C., and will do so at the lowest reasonable impact to the environment. "After weighing all of the information, I believe an emergency situation exists, and that issuance of this order is in the public interest. This order will provide the level of electricity reliability necessary to keep

20

Exergy and Energy analysis of a ground-source heat pump for domestic water heating under simulated occupancy conditions  

SciTech Connect (OSTI)

This paper presents detailed analysis of a water to water ground source heat pump (WW-GSHP) to provide all the hot water needs in a 345 m2 house located in DOE climate zone 4 (mixed-humid). The protocol for hot water use is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which aims to capture the living habits of the average American household and its impact on energy consumption. The entire house was operated under simulated occupancy conditions. Detailed energy and exergy analysis provides a complete set of information on system efficiency and sources of irreversibility, the main cause of wasted energy. The WW-GSHP was sized at 5.275 kW (1.5-ton) for this house and supplied hot water to a 303 L (80 gal) water storage tank. The WW-GSHP shared the same ground loop with a 7.56 kW (2.1-ton) water to air ground source heat pump (WA-GSHP) which provided space conditioning needs to the entire house. Data, analyses, and measures of performance for the WW-GSHP in this paper complements the results of the WA-GSHP published in this journal (Ally, Munk et al. 2012). Understanding the performance of GSHPs is vital if the ground is to be used as a viable renewable energy resource.

Ally, Moonis Raza [ORNL; Munk, Jeffrey D [ORNL; Baxter, Van D [ORNL; Gehl, Anthony C [ORNL

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

''Fraud, abuse, or similar grounds'' exception under Section 601(c)(2) of the NGPA  

SciTech Connect (OSTI)

The determination of what constitutes ''fraud, abuse, or similar grounds'' under the Natural Gas Policy Act has been the subject of extensive litigation before the Federal Energy Regulatory Commission (FERC). Although FERC has consistently held that these grounds do not include imprudence, it has also held that ''the same type of actions of a pipeline can be imprudent or abusive.'' A finding of abuse will result in denial of the pipeline's pass through of gas costs to the extent they are excess due to abuse, and a finding of imprudence may result in denial of the pipeline's recovery of fixed costs. The author analyzes the development of FERC's position, and shows that it may be difficult in some cases for an interstate pipeline to be certain it is in compliance with FERC standards.

Puckett, K.T.

1985-01-01T23:59:59.000Z

22

Measured Performance of Residential Dehumidifiers Under Cyclic Operation  

SciTech Connect (OSTI)

Residential construction practices are progressing toward higher levels of energy efficiency. A proven strategy to save energy is to simultaneously increase building insulation levels and reduce outdoor air infiltration. Tight homes require intentional mechanical ventilation to ensure healthy indoor air. Overall, this strategy results in a shift in the mix of latent and sensible space conditioning loads, requiring proportionally more moisture to be removed compared to standard homes. There is currently not sufficient information available at a wide enough range of operating points to design dehumidification systems for high performance homes in hot-humid climates. The only industry information available on dehumidifier moisture removal and energy consumption are performance ratings conducted at a single test condition, which does not provide a full representation of dehumidifier operation under real-world conditions. Winkler et al. (2011) developed steady state performance maps to predict dehumidifier performance at a variety of indoor conditions. However, installed heating, ventilating, and air-conditioning (HVAC) equipment rarely operates at steady state. Part load performance testing of residential dehumidifiers is not mandated by current test standards. Therefore, we tested the part load performance of four residential dehumidifiers in the National Renewable Energy Laboratory's (NREL) Advanced HVAC Systems Laboratory . The part load efficiency of each dehumidifier was measured under 13 cycling scenarios, and combined with NREL field data to develop part load fraction (PLF) performance curves under realistic cycling scenarios.

Winkler, J.; Christensen, D.; Tomerlin, J.

2014-01-01T23:59:59.000Z

23

Focusing of Rayleigh waves generated by high-speed trains under the condition of ground vibration boom  

E-Print Network [OSTI]

In the present paper, the effects of focusing of Rayleigh waves generated by high speed trains in the supporting ground under the condition of ground vibration boom are considered theoretically. These effects are similar to the effects of focusing of sound waves radiated by aircraft under the condition of sonic boom. In particular, if a railway track has a bend to provide the possibility of changing direction of train movement, the Rayleigh surface waves generated by high-speed trains under the condition of ground vibration boom may become focused. This results in concentration of their energy along a simple caustic line at one side of the track and in the corresponding increase in ground vibration amplitudes. The effect of focusing of Rayleigh waves may occur also if a train moves along a straight line with acceleration and its current speed is higher than Rayleigh wave velocity in the ground. The obtained results are illustrated by numerical calculations.

Krylov, Victor V

2015-01-01T23:59:59.000Z

24

Corrosion-induced degradation of GaAs PHEMTs under operation in high humidity conditions  

E-Print Network [OSTI]

We have comprehensively investigated the degradation mechanism of AlGaAs/InGaAs pseudomorphic high-electron-mobility transistors (PHEMTs) under operation in high humidity conditions. PHEMTs degradation under high humidity ...

Hisaka, Takayuki

25

Biogeochemical Processes Responsible for the Enhanced Transport of Plutonium Under transient Unsaturated Ground Water Conditions  

SciTech Connect (OSTI)

To better understand longer-term vadose zone transport in southeastern soils, field lysimeter experiments were conducted at the Savannah River Site (SRS) near Aiken, SC, in the 1980s. Each of the three lysimeters analyzed herein contained a filter paper spiked with different Pu solutions, and they were left exposed to natural environmental conditions (including the growth of annual weed grasses) for 11 years. The resulting Pu activity measurements from each lysimeter core showed anomalous activity distributions below the source, with significant migration of Pu above the source. Such results are not explainable by adsorption phenomena alone. A transient variably saturated flow model with root water uptake was developed and coupled to a soil reactive transport model. Somewhat surprisingly, the fully transient analysis showed results nearly identical to those of a much simpler steady flow analysis performed previously. However, all phenomena studied were unable to produce the upward Pu transport observed in the data. This result suggests another transport mechanism such as Pu uptake by roots and upward transport due to transpiration. Thus, the variably saturated flow and reactive transport model was extended to include uptake and transport of Pu within the root xylem, along with computational methodology and results. In the extended model, flow velocity in the soil was driven by precipitation input along with transpiration and drainage. Water uptake by the roots determined the flow velocity in the root xylem, and this along with uptake of Pu in the transpiration stream drove advection and dispersion of the two Pu species in the xylem. During wet periods with high potential evapotranspiration, maximum flow velocities through the xylem would approached 600 cm/hr, orders of magnitude larger that flow velocities in the soil. Values for parameters and the correct conceptual viewpoint for Pu transport in plant xylem was uncertain. This motivated further experiments devoted to Pu uptake by corn roots and xylem transport. Plants were started in wet paper wrapped around each corn seed. When the tap roots were sufficiently long, the seedlings were transplanted to a soil container with the tap root extending out the container bottom. The soil container was then placed over a nutrient solution container, and the solution served as an additional medium for root growth. To conduct an uptake study, a radioactive substance, such as Pu complexed with the bacterial siderophore DFOB, was added to the nutrient solution. After a suitable elapsed time, the corn plant was sacrificed, cut into 10 cm lengths, and the activity distribution measured. Experimental results clarified the basic nature of Pu uptake and transport in corn plants, and resulting simulations suggested that each growing season Pu in the SRS lysimeters would move into the plant shoots and be deposited on the soil surface during the Fall dieback. Subsequent isotope ratio analyses showed that this did happen. OVERALL RESULTS AND CONCLUSIONS - (1) Pu transport downward from the source is controlled by advection, dispersion and adsorption, along with surface-mediated REDOX reactions. (2) Hysteresis, extreme root distribution functions, air-content dependent oxidation rate constants, and large evaporation rates from the soil surface were not able to explain the observed upward migration of Pu. (3) Small amounts of Pu uptake by plant roots and translocation in the transpiration stream creates a realistic mechanism for upward Pu migration (4) Realistic xylem cross-sectional areas imply high flow velocities under hot, wet conditions. Such flow velocities produce the correct shape for the observed activity distributions in the top 20 cm of the lysimeter soil. (5) Simulations imply that Pu should have moved into the above-ground grass tissue each year during the duration of the experiments, resulting in an activity residual accumulating on the soil surface. An isotope ratio analysis showed that the observed surface Pu residue was from the buried sources, not atmospheric fallout. (6) The

Fred J. Molz, III

2010-05-28T23:59:59.000Z

26

Optimal design and operation of energy systems under uncertainty  

Science Journals Connector (OSTI)

Abstract This paper is concerned with integrated design and operation of energy systems that are subject to significant uncertainties. The problem is cast as a two-stage stochastic programming problem, which can be transformed into a large-scale nonconvex mixed-integer nonlinear programming problem (MINLP). The MINLP exhibits a decomposable structure that can be exploited by nonconvex generalized Benders decomposition (NGBD) for efficient global optimization. This paper extends the NGBD method developed by the authors recently, such that the method can handle non-separable functions and integer operational decisions. Both the standard NGBD algorithm and an enhanced one with piecewise convex relaxations are discussed. The advantages of the proposed formulation and solution method are demonstrated through case studies of two industrial energy systems, a natural gas production network and a polygeneration plant. The first example shows that the two-stage stochastic programming formulation can result in better expected economic performance than the deterministic formulation, and that NGBD is more efficient than a state-of-the-art global optimization solver. The second example shows that the integration of piecewise convex relaxations can improve the efficiency of NGBD by at least an order of magnitude.

Xiang Li; Paul I. Barton

2014-01-01T23:59:59.000Z

27

1 Grounding Symbolic Operations in the Brain's M,odal Systems  

E-Print Network [OSTI]

['edications further support high-level cogni tIve operations, such as deCISion makll1g (e.g., purchaslllg:l gas), they have also been central throughout accounts of human cognition (e.g., Barsalou, 1992; Barsalou & Hale

Barsalou, Lawrence W.

28

Performance of an experimental ground-coupled heat pump system for heating, cooling and domestic hot-water operation  

Science Journals Connector (OSTI)

Abstract The ground-coupled heat pump (GCHP) system is a type of renewable energy technology providing space heating and cooling as well as domestic hot water. However, experimental studies on GCHP systems are still insufficient. This paper first presents an energy-operational optimisation device for a GCHP system involving insertion of a buffer tank between the heat pump unit and fan coil units and consumer supply using quantitative adjustment with a variable speed circulating pump. Then, the experimental measurements are used to test the performance of the GCHP system in different operating modes. The main performance parameters (energy efficiency and CO2 emissions) are obtained for one month of operation using both classical and optimised adjustment of the GCHP system, and a comparative analysis of these performances is performed. In addition, using TRNSYS (Transient Systems Simulation) software, two simulation models of thermal energy consumption in heating, cooling and domestic hot-water operation are developed. Finally, the simulations obtained using TRNSYS are analysed and compared to experimental data, resulting in good agreement and thus the simulation models are validated.

Calin Sebarchievici; Ioan Sarbu

2015-01-01T23:59:59.000Z

29

START-3: Operational Evaluations of the ISUS Engine Ground Demonstration Thermionic Power System  

SciTech Connect (OSTI)

START-3 was a test program conducted in order to demonstrate and characterize the operational performance of the prototype Integrated Solar Upper Stage (ISUS) thermionic power system. The test device consisted of a graphite thermal storage uni~ multilayer foil insulation, and sixteen thermionic converters electrically connected in a series array. Several thermal input conditions were achieved during the test, which resulted in measuring converter performance at average converter hot shoe temperatures in the range of 1600 K to 2000 K. Results indicate that the ;hermionic converter; did not perform as weil as expected in the array individual sixteen converters is currently being performed.

Luchau, D.W.; Luke, J.R.; Wyant, F.J.

1998-10-08T23:59:59.000Z

30

START-3: Operational evaluations of the ISUS engine ground demonstration thermionic power system  

SciTech Connect (OSTI)

START-3 was a test program conducted in order to demonstrate and characterize the operational performance of the prototype Integrated Solar Upper Stage (ISUS) thermionic power system. The test device consisted of a graphite thermal storage unit, multilayer foil insulation, and sixteen thermionic converters electrically connected in a series array. Several thermal input conditions were achieved during the test, which resulted in measuring converter performance at average converter hot shoe temperatures in the range of 1600 K to 2000 K. Results indicate that the thermionic converters did not perform as well as expected in the array configuration. Follow-on testing of the individual sixteen converters is currently being performed. {copyright} {ital 1999 American Institute of Physics.}

Wyant, Francis J. [Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185 (United States)] Luke, James R. [New Mexico Engineering Research Institute, 901 University Blvd., SE, Albuquerque, New Mexico 87106 (United States)] Luchau, David W. [TEAM Specialty Services, Inc., 11030 Cochiti Rd., SE, Albuquerque, New Mexico 87123 (United States)

1999-01-01T23:59:59.000Z

31

Analysis of photovoltaic module energy output under operating conditions in South Africa  

SciTech Connect (OSTI)

South Africa does not have any industry standard methodology to evaluate photovoltaic (PV) modules for energy production. The aim of this study is to characterize the energy production of PV modules deployed outdoors at the University of Port Elizabeth (UPE), Summerstrand, South Africa with the view of facilitating such a standard. The system developed for this study was designed to monitor the energy production of seven PV modules under normal operating conditions. An analysis of energy production of three of the PV modules under test, while operating under prevailing outdoor conditions, is given. Measured energy output is also compared with that predicted using an energy model.

Dyk, E.E. van; Meyer, E.L.; Scott, B.J.; O`Connor, D.A.; Wessels, J.B. [Univ. of Port Elizabeth (South Africa). Dept. of Physics

1997-12-31T23:59:59.000Z

32

A Modified Analytical Method for Simulating Cyclic Operation of Vertical U-Tube Ground-Coupled Heat Pumps  

E-Print Network [OSTI]

A modified analytical model is presented which discretizes the ground-coupled heat exchanger of a ground-coupled heat pump and utilized a separate cylindrical source solution for each element. First law expressions are utilized for each element...

Dobson, M. K.; O'Neal, D. L.; Aldred, W.

1994-01-01T23:59:59.000Z

33

ANEMOS: A computer code to estimate air concentrations and ground deposition rates for atmospheric nuclides emitted from multiple operating sources  

SciTech Connect (OSTI)

This code estimates concentrations in air and ground deposition rates for Atmospheric Nuclides Emitted from Multiple Operating Sources. ANEMOS is one component of an integrated Computerized Radiological Risk Investigation System (CRRIS) developed for the US Environmental Protection Agency (EPA) for use in performing radiological assessments and in developing radiation standards. The concentrations and deposition rates calculated by ANEMOS are used in subsequent portions of the CRRIS for estimating doses and risks to man. The calculations made in ANEMOS are based on the use of a straight-line Gaussian plume atmospheric dispersion model with both dry and wet deposition parameter options. The code will accommodate a ground-level or elevated point and area source or windblown source. Adjustments may be made during the calculations for surface roughness, building wake effects, terrain height, wind speed at the height of release, the variation in plume rise as a function of downwind distance, and the in-growth and decay of daughter products in the plume as it travels downwind. ANEMOS can also accommodate multiple particle sizes and clearance classes, and it may be used to calculate the dose from a finite plume of gamma-ray-emitting radionuclides passing overhead. The output of this code is presented for 16 sectors of a circular grid. ANEMOS can calculate both the sector-average concentrations and deposition rates at a given set of downwind distances in each sector and the average of these quantities over an area within each sector bounded by two successive downwind distances. ANEMOS is designed to be used primarily for continuous, long-term radionuclide releases. This report describes the models used in the code, their computer implementation, the uncertainty associated with their use, and the use of ANEMOS in conjunction with other codes in the CRRIS. A listing of the code is included in Appendix C.

Miller, C.W.; Sjoreen, A.L.; Begovich, C.L.; Hermann, O.W.

1986-11-01T23:59:59.000Z

34

Evaluation of the ISUS power management and distribution system under operational conditions  

Science Journals Connector (OSTI)

An operational evaluation of the Integrated Solar Upper Stage (ISUS) power management and distribution (PMAD) system was conducted as part of the Engine Ground Demonstration thermionic power system test program—START-3. START-3 testing took place at the Baikal Test Stand located in the University of New Mexico’s Energy Conversion Research Laboratory at the New Mexico Engineering Research Institute in Albuquerque NM. One objective of this test was to evaluate the operational performance of the ISUS PMAD system developed by the NASA Lewis Research Center. Tests of the PMAD with the ISUS diode string demonstrated that the PMAD could regulate the output of an array of thermionic converters within the design requirements and could be modified to optimize performance for diode strings of fewer than 16 diodes.

S. Michael Luker; F. J. Wyant; R. C. Nelson; Robert M. Button

1999-01-01T23:59:59.000Z

35

Invariance Under Stuttering in a Temporal Logic without the "Until" Operator  

Science Journals Connector (OSTI)

We show that a stutter-invariant property is expressible in propositional temporal logic without the "until" operator if and only if it is expressible in the Generalized Temporal Logic of Actions. Keywords: Propositional temporal logic, invariance under stuttering, temporal interpretations

Michael Kaminski

2008-07-01T23:59:59.000Z

36

JOIDES Resolution Ship Security Plan The JOIDES Resolution is operating under the International Ship &  

E-Print Network [OSTI]

JOIDES Resolution Ship Security Plan The JOIDES Resolution is operating under the International or the Ship Security Plan is not followed. The JOIDES Resolution's Ship Security Plan has been approved by its and personnel will be searched as required in accordance with the ISPS code, the Ship Security Plan

37

Covanta Begins Operating Nation's First Energy-from-Waste Unit under the EPA's New Source Performance Standards  

E-Print Network [OSTI]

Covanta Begins Operating Nation's First Energy-from-Waste Unit under the EPA's New Source in the development and operation of large scale Energy-from-Waste and renewable energy projects, today announced it has begun operating the first energy-from-waste unit built under the U.S. Environmental Protection

Columbia University

38

Temperature limits for LMFBR fuel cladding under upset and emergency operating conditions  

SciTech Connect (OSTI)

LMFBR fuel pin cladding tube is subjected to high transient temperatures during incidents such as pump trip, pump to grid plate pipe rupture etc. It is required to know temperature limits under such transient operating conditions for components involved while analyzing such incidents. A methodology for deriving such limits for fuel clad tube is worked out in this paper by making use of the transient damage correlation proposed by W.F. Brizes et. al.

Govindarajan, S.; Chetal, S.C. [Indira Gandhi Centre for Atomic Research, Kalpakkam Tamilnadu (India). Nuclear Systems Division

1996-07-01T23:59:59.000Z

39

Investigation of MEA degradation in a passive direct methanol fuel cell under different modes of operation  

Science Journals Connector (OSTI)

Abstract Direct methanol fuel cell (DMFC) durability tests were conducted in three different operational modes: continuous operation with constant load (LT1), on–off operation with constant load (LT2) and on–off operation with variable load (LT3). Porous carbon nanofiber (CNF) anode layers were employed in three sets of single passive DMFCs; each membrane electrode assembly (MEA) was run continuously in durability testing for 3000 h. The objective of this study is to investigate the degradation mechanisms in an MEA with a porous CNF anode layer under different modes of operation. The polarization curves of single passive \\{DMFCs\\} before and after durability tests were compared. The degradation of DMFC performance under the cyclic LT1 mode was much more severe than that of LT2 and LT3 operation. The loss of maximum power density after degradation tests was 49.5%, 28.4% and 43.7% for LT1, LT2 and LT3, respectively. TEM, SEM and EDS mapping were used to investigate the causes of degradation. The lower power loss for LT2 was mainly attributed to the reversible degradation caused by poor water discharge, which thus reduced the air supply. Catalyst agglomeration was especially observed in LT1 and LT3 and is related to carbon corrosion due to possible fuel starvation. The loss of active catalyst area was a major cause of performance degradation in LT1 and LT3. In addition to this, the dissolution and migration of Ru catalyst from the anode to cathode was identified and correlated with degraded cell performance. In the DMFC, the carbon nanofiber anode catalyst support exhibited higher performance stability with less catalyst agglomeration than the cathode catalyst support, carbon black. This study helps understand and elucidate the failure mechanism of MEAs, which could thus help to increase the lifetime of DMFCs.

A.M. Zainoodin; S.K. Kamarudin; M.S. Masdar; W.R.W. Daud; A.B. Mohamad; J. Sahari

2014-01-01T23:59:59.000Z

40

Superfund record of decison (EPA Region 3): Aberdeen Proving Ground (Edgewood Area), J-field soil operable unit, Aberdeen Proving Ground, MD, September 27, 1996  

SciTech Connect (OSTI)

This Operable Unit (OU) consists of two main burn pits (the Northern Main Burn Pit and Southern Main Burn Pit). It also includes the Pushout Area, which consists of the O-ethyl-S-(2-iisoprop ylaminoethyl)methyl phosphonothiolate (VX) Burn Pit, the Mustard Burn Pit, and the Liquid Smoke Disposal Pit. This decision document addresses the actions to be taken toward remediating the principal threats provided by high levels of arsenic, lead, and PCBs at the J-Field SOU: (1) the removal of isolated hot spots of contamination from the SOU followed by (2) the construction of a Protective Soil Blanket (PSB) over the J-Field SOU.

NONE

1996-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Investigation of the recoverable degradation of PEM fuel cell operated under drive cycle and different humidities  

Science Journals Connector (OSTI)

Abstract Recoverable degradation of a proton exchange membrane fuel cell (PEMFC) under different relative humidities (RHs) after a whole night rest was investigated. A single cell was operated under drive cycle to simulate the working conditions of fuel cell vehicle. It was found that the cell performance decreased after 5 h operation and recovered mostly after one night rest at higher humidities, i.e. 100%, 75% and 50% RH for both cathode and anode sides; while continuous decrease took place at lower humidity, 35%RH. Polarization curve, electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and linear sweep voltammetry (LSV) were conducted before and after every 5 h drive cycle for investigating the mechanism of the recoverable degradation. It was found that water content, current density and thermal management might be the main contributions to the performance degradation, by impacting the membrane conductivity, internal resistance, electrode kinetics, and catalyst utilization. A good understanding of voltage recovery phenomenon after several hours rest and its effect on durability will be helpful in improving the reliability and durability of PEMFC.

Feijie Wang; Daijun Yang; Bing Li; Hao Zhang; Chuanpu Hao; Fengrui Chang; Jianxin Ma

2014-01-01T23:59:59.000Z

42

Accumulated photon echo in ruby under hydrostatic pressure: Ground-state splitting and spontaneous decay of 2A¯(2E)  

Science Journals Connector (OSTI)

The technique of accumulated photon echo is used in combination with a high-pressure diamond anvil cell to measure the splitting of the 4A2 ground state and the one-phonon spontaneous decay rate of the 2A¯(2E) level at 1.5 K in ruby up to 4.3 GPa of hydrostatic pressure. The 4A2 ground-state splitting is found to be 0.383±0.001 cm-1 at ambient pressure, and increases with a slope of +(6±1)×10-3 cm-1/GPa. The spontaneous decay rate of 2A¯(2E) increases only weakly with pressure. The pressure dependences of both quantities are accounted for in terms of the trigonal-field and spin-orbit-coupling parameters.

M. H. F. Overwijk; J. I. Dijkhuis; H. W. de Wijn; R. Vreeker; R. Sprik; A. Lagendijk

1991-06-01T23:59:59.000Z

43

Study of combustion noise mechanism under accelerating operation of a naturally aspirated diesel engine  

Science Journals Connector (OSTI)

This paper studies combustion noise mechanism during transient operation of naturally aspirated-DI-Diesel engines by developing testing techniques and methods. By testing and analysing four load conditions, the mechanism that governs the differences between transient and steady-state combustion noise is studied. The analysis demonstrates that during transients, the combustion chamber wall temperature, fuel injection pressure, maximum needle lift and unseal standing time of needle lift are higher than those under steady-state conditions for the same speed and load; a fact causing differences in ignition delay, start point of combustion and fuel injection quantity during transient conditions with a low acceleration rate. It is shown that the differences between the combustion chamber wall temperature, fuel injection pressure and ignition delay, as well as high-frequency oscillation of combustion pressure develop during transients in a different pattern compared to the respective steady-state conditions, thus resulting in different combustion noise emissions.

Gequn Shu; Haiqiao Wei

2007-01-01T23:59:59.000Z

44

Experimental and numerical study of the behavior of three-way catalytic converters under different engine operation conditions  

E-Print Network [OSTI]

The thesis reports the studies on how the three-way catalytic converters behave under different operation conditions. The main focus of the work is in the oxygen storage capacity of the three-way catalyst. Rich-to-lean ...

Zhang, Yuetao

2005-01-01T23:59:59.000Z

45

Ion engineering techniques for the preparation of the highly effective TiO2 photocatalysts operating under visible light irradiation  

Science Journals Connector (OSTI)

The successful application of ion engineering techniques for the development of TiO2...photocatalysts operating under visible and/or solar light irradiations has been summarized in this review article. First, we ...

Masato Takeuchi; Masaya Matsuoka; Masakazu Anpo

2012-04-01T23:59:59.000Z

46

Work attitudes and intention to quit among workers in private child welfare agencies operating under performance-based contracts  

E-Print Network [OSTI]

Not much is currently known about how employment in child welfare agencies operating under performance-based contracts affects worker attitudes related to retention. This study focuses on the relationship of job satisfaction, ...

Levy, Michelle; Poertner, John; Lieberman, Alice

2012-02-01T23:59:59.000Z

47

Estimation of Ground-Level Reflectivity Factor in Operational Weather Radar Networks Using VPR-Based Correction Ensembles  

Science Journals Connector (OSTI)

An operational method is presented that corrects the bias of radar-based quantitative precipitation estimations (QPE) in radar networks that is due to the vertical profile of reflectivity (VPR) factor. It is used in both rain and snowfall. ...

Jarmo Koistinen; Heikki Pohjola

2014-10-01T23:59:59.000Z

48

Operation Castle. Project 7. 1. Electromagnetic radiation calibration, Pacific )roving ground. Report for March-May 1954  

SciTech Connect (OSTI)

A total of 17 stations, one close-in (320 km from Bikini and 23 km from Eniwetok) and the balance at distances, were operated for the electromagnetic experimental effort. Seventy-four sets of data were obtained from a possible total of 102. Of the remaining 28 sets, no data were obtained because equipment was not in operation, records were not readable, the alert notifications were not received, signals were not discernible, or equipment malfunctioned.

Olseon, M.H.

1984-08-31T23:59:59.000Z

49

A dynamic model for air-based photovoltaic thermal systems working under real operating conditions  

Science Journals Connector (OSTI)

Abstract In this paper a dynamic model suitable for simulating real operating conditions of air-based photovoltaic thermal (PVT) systems is presented. The performance of the model is validated by using the operational data collected from the building integrated photovoltaic (PVT) systems installed in two unique buildings. The modelled air outlet temperature and electrical power match very well with the experimental data. In Solar Decathlon house PVT, the average (RMS) error in air outlet temperatures was 4.2%. The average (RMS) error in electrical power was also 4.2%. In the Sustainable Buildings Research Centre PVT, the average errors (RMS) of PV and air temperatures were 3.8% and 2.2%, respectively. The performance of the PVT system under changing working condition is also analysed in this paper. The analysis includes the effect of ambient air temperature, air inlet temperature, air flow rate and solar irradiation on thermal, electrical, first law and second law efficiencies. Both the thermal and the 1st law efficiencies almost linearly increased with the increase of the ambient temperature. However, the PVT electrical efficiency and the second law efficiency decreased with the increase of the ambient temperature. All efficiencies expect the second law efficiency decreased with increase of the PVT air inlet temperature. The second law efficiency first increased and then reduced. With increasing the air flow rate all the efficiencies increased. The electrical and second law efficiencies become less sensitive when the air flow rate exceeded 300 l/s. Both the thermal and the 1st law efficiencies decreased while the electrical efficiency and the second law efficiency increased with the increase of the solar irradiation. The efficiencies found to be very sensitive for low level of solar irradiations. At about 400 W m?2 irradiation efficiencies became less sensitive.

M. Imroz Sohel; Zhenjun Ma; Paul Cooper; Jamie Adams; Robert Scott

2014-01-01T23:59:59.000Z

50

1981). Their basic solution is to find a suitable backfilling material to minimize the contact resistance and to maintain high ground thermal conductivity around the cable even under very  

E-Print Network [OSTI]

#12;1981). Their basic solution is to find a suitable backfilling material to minimize the contact resistance and to maintain high ground thermal conductivity around the cable even under very dry ground contact resistance or soil dry-out or both. This paper presents a mathematical model describing

Oak Ridge National Laboratory

51

Neutronics and Fuel Performance Evaluation of Accident Tolerant Fuel under Normal Operation Conditions  

SciTech Connect (OSTI)

This report details the analysis of neutronics and fuel performance analysis for enhanced accident tolerance fuel, with Monte Carlo reactor physics code Serpent and INL’s fuel performance code BISON, respectively. The purpose is to evaluate two of the most promising candidate materials, FeCrAl and Silicon Carbide (SiC), as the fuel cladding under normal operating conditions. Substantial neutron penalty is identified when FeCrAl is used as monolithic cladding for current oxide fuel. From the reactor physics standpoint, application of the FeCrAl alloy as coating layer on surface of zircaloy cladding is possible without increasing fuel enrichment. Meanwhile, SiC brings extra reactivity and the neutron penalty is of no concern. Application of either FeCrAl or SiC could be favorable from the fuel performance standpoint. Detailed comparison between monolithic cladding and hybrid cladding (cladding + coating) is discussed. Hybrid cladding is more practical based on the economics evaluation during the transition from current UO2/zircaloy to Accident Tolerant Fuel (ATF) system. However, a few issues remain to be resolved, such as the creep behavior of FeCrAl, coating spallation, inter diffusion with zirconium, etc. For SiC, its high thermal conductivity, excellent creep resistance, low thermal neutron absorption cross section, irradiation stability (minimal swelling) make it an excellent candidate materials for future nuclear fuel/cladding system.

Xu Wu; Piyush Sabharwall; Jason Hales

2014-07-01T23:59:59.000Z

52

Assessing the Role of Operating, Passenger, and Infrastructure Costs in Fleet Planning under Fuel Price Uncertainty  

E-Print Network [OSTI]

ICKET . Aircraft Category Fuel Price (FP) Coefficient SL*FPin Fleet Planning under Fuel Price Uncertainty Megan Smirti,in Fleet Planning under Fuel Price Uncertainty Megan Smirti,

Smirti, Megan; Hansen, Mark

2009-01-01T23:59:59.000Z

53

Eigenvalue Analysis of a DFIG Based Wind Power System under Different Modes of Operations  

Science Journals Connector (OSTI)

This chapter discussed the various mode of operation of the Doubly Fed Induction Generator (DFIG) based wind farm system. The impact ... on the different modes of operation for the DFIG based wind generation syst...

Y. Mishra; S. Mishra; Fangxing Li; Z. Y. Dong

2010-01-01T23:59:59.000Z

54

A computational framework for risk-based power systems operations under uncertainty. Part I: Theory  

Science Journals Connector (OSTI)

Abstract With larger penetrations of wind power, the uncertainty increases in power systems operations. The wind power forecast errors must be accounted for by adapting existing operating tools or designing new ones. A switch from the deterministic framework used today to a probabilistic one has been advocated. This two-part paper presents a framework for risk-based operations of power systems. This framework builds on the operating risk defined as the probability of the system to be outside the stable operation domain, given probabilistic forecasts for the uncertainty (load and wind power generation levels) and outage rates of chosen elements of the system (generators and transmission lines). This operating risk can be seen as a probabilistic formulation of the N ? 1 criterion. The stable operation domain is defined by voltage-stability limits, small-signal stability limits, thermal stability limits and other operating limits. In Part I of the paper, a previous method for estimating the operating risk is extended by using a new model for the joint distribution of the uncertainty. This new model allows for a decrease in computation time of the method, which allows for the use of later and more up-to-date forecasts. In Part II, the accuracy and the computation requirements of the method using this new model will be analyzed and compared to the previously used model for the uncertainty. The method developed in this paper is able to tackle the two challenges associated with risk-based real-time operations: accurately estimating very low operating risks and doing so in a very limited amount of time.

Camille Hamon; Magnus Perninge; Lennart Söder

2015-01-01T23:59:59.000Z

55

Substation grounding.  

E-Print Network [OSTI]

??Designing a proper substation grounding system is quite complicating. Many parameters affect its design. In order for a grounding design to be safe, it needs… (more)

Baleva, Inna

2012-01-01T23:59:59.000Z

56

Memorandum requesting a clarification of the circumstances under which a DOE Government Owned Contractor Operated (GOCO) facility  

Broader source: Energy.gov [DOE]

Memorandum requesting a clarification of the circumstances under which a DOE Government Owned Contractor Operated (GOCO) facility may be considered a laser manufacturer and subject to FDA laser manufacturer requirements and other points of interpretation of the FDA Exemption Letter, 78EL-01DOE (DOE exemption or exemption) by the LSSG for GOCG facilities.

57

Voltage Oscillations in Single-Chamber Fuel Cells operating under a C3H8 / O2 mixture.  

E-Print Network [OSTI]

1 Voltage Oscillations in Single-Chamber Fuel Cells operating under a C3H8 / O2 mixture. Geoffroy : Jean-Paul Viricelle, viricelle@emse.fr Phone : 33 4 77 42 02 52 Abstract : Single-Chamber Fuel Cells this behaviour. Keywords: Single Chamber Fuel Cell, Propane, Oscillation, Anode. 1. Introduction Solid Oxide Fuel

Paris-Sud XI, Université de

58

The torsional vibrations of marine Diesel engines under fault operation of its cylinders  

Science Journals Connector (OSTI)

The torsional vibrations calculation of Diesel engines is usually performed for different speeds of revolutions but for uniform operation and behaviour of each cylinder. This condition is true only for new of ...

Dr.-Ing. Ioannis E. Margaronis

1992-01-01T23:59:59.000Z

59

Thermal Performance Characteristics of a Combined External Insulation System under Simulated Space Vehicle Operating Conditions  

Science Journals Connector (OSTI)

The main purpose of this investigation was to determine the long-term thermal performance characteristics, with liquid hydrogen, of an externally applied combined foam/multilayer insulation system under simulated...

F. J. Muller; P. L. Klevatt

1995-01-01T23:59:59.000Z

60

Ionization interferences under various operating conditions in a 9, 27 and 50 \\{MHz\\} ICP, and a study of shifts in level populations of calcium through simultaneous absorption-emission measurements in a 9 \\{MHz\\} ICP  

Science Journals Connector (OSTI)

Radially resolved absorption and emission measurements were employed for a better understanding of the excitation mechanism of nebulized species operating under conditions favourable for the occurrence of ionization interferences in an atmospheric pressure 9 \\{MHz\\} ICP. Three monitored spectral lines of calcium were used to observe changes in ground and excited level populations of atoms and ions, in ion excitation temperatures using the two-line method. Observations were made at a fixed height, namely 25 mm above the rf coil and varying carrier gasflows from 2 to 51 min?1 and were correlated with the position of the “initial radiation zone” (IRZ) in the plasma. Ionization interferences occurring only inside the IRZ indicate an excitation mechanism depleting ion ground level population and populating excited atom and ion levels. No changes in atom absorbances or excitation temperatures were observed ruling out ionization suppression as dominating mechanism. Indications are that increased collisional excitation for Ca ions and ambipolar diffusion may be the dominant excitation mechanism operating in the analyte channel. Recombination reactions (three body or radiative) or charge transfer reactions may be responsible for an increase of excited atom level populations. It is obvious that non-thermal processes are operating under conditions favourable for ionization interferences occurring in the ICP.

W. Gunter; K. Visser; P.B. Zeeman

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Design and construction of uniform glow discharge plasma system operating under atmospheric condition  

SciTech Connect (OSTI)

The design of a uniform glow discharge plasma system operating without vacuum is presented. A full-bridge switching circuit was used to switch the transformers. The primary windings of transformers were connected in parallel, but in opposite phase to double the output voltage. Theoretically, 20 000 V{sub pp} was obtained. Rectangle copper electrodes were used, and placed parallel to each other. To prevent the spark production that is, to obtain uniformity, two 2 mm Teflon sheets were glued to the electrodes. However, it was observed that the operating frequency also affected the uniformity. For the system presented here, the frequency at which more uniformity was obtained was found to be 14 kHz.

Kocum, C.; Ayhan, H. [Biomedical Engineering Department, Baskent University, Ankara 06530 (Turkey); Chemistry Department, Biochemistry Division, Mugla University, Faculty of Science, Koetekli, 48170 Mugla (Turkey)

2007-06-15T23:59:59.000Z

62

Operation of mixed conducting metal oxide membrane systems under transient conditions  

DOE Patents [OSTI]

Method of operating an oxygen-permeable mixed conducting membrane having an oxidant feed side, an oxidant feed surface, a permeate side, and a permeate surface, which method comprises controlling the differential strain between the permeate surface and the oxidant feed surface at a value below a selected maximum value by varying the oxygen partial pressure on either or both of the oxidant feed side and the permeate side of the membrane.

Carolan, Michael Francis (Allentown, PA)

2008-12-23T23:59:59.000Z

63

Fission Product Transport in TRISO Particle Layers under Operating and Off-Normal Conditions  

SciTech Connect (OSTI)

The objective of this project is to determine the diffusivity and chemical behavior of key fission products (ag, Cs, I. Te, Eu and Sr) through SiC and PyC both thermally, under irradiation, and under stress using FP introduction techniques that avoid the pitfalls of past experiments. The experimental approach is to create thin PyC-SiC couples containing the fission product to be studied embedded in the PyC layer. These samples will then be subjected to high temperature exposures in a vacuum and also to irradiation at high temperature, and last, to irradiation under stress at high temperature. The PyC serves as a host layer, providing a means of placing the fission product close to the SiC without damaging the SiC layer by its introduction or losing the FP during heating. Experimental measurements of grain boundary structure and distribution (EBSD, HRTEM, APT) will be used in the modeling effort to determine the qualitative dependence of FP diffusion coefficients on grain boundary orientation, temperature and stress.

Van der Ven, Anton; Was, Gary; Wang, Lumin; Taheri, Mitra

2014-07-07T23:59:59.000Z

64

Ground Water Ground Sky Sky Water Vegetation Ground Vegetation Water  

E-Print Network [OSTI]

Bear Snow Vegetation RhinoWater Vegetation Ground Water Ground Sky Sky Rhino Water Vegetation Ground Vegetation Water Rhino Water Vegetation Ground Rhino Water Rhino Water Ground Ground Vegetation Water Rhino Vegetation Rhino Vegetation Ground Rhino Vegetation Ground Sky Rhino Vegetation Ground Sky

Chen, Tsuhan

65

Integral energy performance characterization of semi-transparent photovoltaic elements for building integration under real operation conditions  

Science Journals Connector (OSTI)

Abstract In this paper, a methodology for the integral energy performance characterization (thermal, daylighting and electrical behavior) of semi-transparent photovoltaic modules (STPV) under real operation conditions is presented. An outdoor testing facility to analyze simultaneously thermal, luminous and electrical performance of the devices has been designed, constructed and validated. The system, composed of three independent measurement subsystems, has been operated in Madrid with four prototypes of a-Si STPV modules, each one corresponding to a specific degree of transparency. The extensive experimental campaign, continued for a whole year rotating the modules under test, has validated the reliability of the testing facility under varying environmental conditions. The thermal analyses show that both the solar protection and insulating properties of the laminated prototypes are lower than those achieved by a reference glazing whose characteristics are in accordance with the Spanish Technical Building Code. Daylighting analysis shows that STPV elements have an important lighting energy saving potential that could be exploited through their integration with strategies focused to reduce illuminance values in sunny conditions. Finally, the electrical tests show that the degree of transparency is not the most determining factor that affects the conversion efficiency.

L. Olivieri; E. Caamaño-Martin; F .Olivieri; J. Neila

2014-01-01T23:59:59.000Z

66

CFD Simulation of the CANDU-6 Moderator Circulation Under Normal Operating Conditions  

SciTech Connect (OSTI)

A steady-state 3D simulation for predicting the local subcooling of the moderator in the vicinity of the calandria tubes in a CANDU-6 reactor is performed. For the current simulation, a set of grid structures with the same geometry as the CANDU-6 moderator tank, called 'calandria vessel', is generated and the momentum, heat and continuity equations are solved by CFX-4.3, a CFD code developed by AEA technology. The standard k-{epsilon} turbulence model associated with logarithmic wall treatment is used to model turbulence generation and dissipation within the vessel. The moderator fluid is heavy water. Buoyancy forces are modeled using the Boussinesq approximation in which density is assumed to be a linear function of temperature. The matrix of the calandria tubes in the center region of the calandria vessel is simplified by the porous media approach. The anisotropic hydraulic impedance of the calandria tubes is modeled using the frictional pressure drop correlations suggested by Idelchik and Szymanski. The heat load in this steady-state simulation is conservatively set as 103 MW of 103% full power, consisting of 96.7 MW to the core region and 6.3 MW to the reflector region. The total volumetric flow rate through eight inlet nozzles is 940 L/s and the outlet temperature is constantly 71.0 deg. C. The thermal boundary condition of the circumferential vessel wall is assumed a little heat flux out. As a result, the velocity field and temperature distribution of a CANDU-6 moderator in the operating condition are presented. The flow pattern identified in this simulation is the weak jet momentum-dominated flow, which is generated by the interaction between the buoyancy force by heating and the dominant momentum forces by inlet jets. The calculated maximum temperature of the moderator is 83.0 deg. C at the lower center region of the core, which corresponds to the minimum subcooling of 33.0 deg. C considering the boiling point increase due to the hydrostatic pressure change. (authors)

Bo Wook Rhee; Churl Yoon; Byung-Joo Min [Korea Atomic Energy Research Institute, 150, Dukjin-Dong, Yusong-Gu, Taejon 305-353 (Korea, Republic of)

2002-07-01T23:59:59.000Z

67

Ground Water Management Regulations (Louisiana)  

Broader source: Energy.gov [DOE]

The rules and regulations apply to the management of the state's ground water resources. In addition, the Commissioner of Conservation has recommended that oil and gas operators with an interest...

68

Rational analysis of mass, momentum, and heat transfer phenomena in liquid storage tanks under realistic operating conditions: 1. Basic formulation  

SciTech Connect (OSTI)

This paper presents a computer code that analyses the performance of storage tanks using water as the working fluid. The new aspects of the authors work include the following items: (a) the transient Navier-Stokes equations are expressed in two-dimensional Cartesian and cylindrical coordinates, under the assumption of the Boussinesq approximation, (b) the effective viscosity and thermal diffusivity are evaluated by using a simplified form of the Deardorff turbulence model, (c) the energy equation is solved over a domain which includes the tank and a large portion of the surrounding soil, (d) some properly defined source terms have been introduced in the governing equations to describe inlet/outlet devices inside the tank, and localized friction losses, and (e) the boundary conditions are time-dependent to correctly describe the daily heat exchanges between tank, solar collectors and heat pumps for space conditioning. The Finite Differences (FD) technique and an improved formulation of the Marker and Cell (MAC) method are used to solve the conservation equations. Comparisons with literature studies indicate discrepancies between 0.02 and 0.5%. The results of several tests simulating realistic operating conditions will be shown in the second part of the paper.

Parrini, F.; Vitale, S.; Alabiso, M. (ENEL-Italian National Electricity Board-CRTN, Milan (Italy)); Castellano, L. (MATEC S.r.l., Milan (Italy))

1992-08-01T23:59:59.000Z

69

DOE - Office of Legacy Management -- Naval Proving Ground - VA 0-01  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Proving Ground - VA 0-01 Proving Ground - VA 0-01 FUSRAP Considered Sites Site: NAVAL PROVING GROUND (VA.0-01 ) Eliminated from further consideration under FUSRAP - Referred to DOD Designated Name: Not Designated Alternate Name: None Location: Dahlgren , Virginia VA.0-01-1 Evaluation Year: 1987 VA.0-01-1 Site Operations: Site operations were not specified; this site was identified on the 1954 Accountable Station Lists. VA.0-01-1 VA.0-01-2 Site Disposition: Eliminated - Referred to DOD VA.0-01-1 Radioactive Materials Handled: None Indicated Primary Radioactive Materials Handled: None Radiological Survey(s): None Indicated Site Status: Eliminated from further consideration under FUSRAP - Referred to DOD VA.0-01-1 Also see Documents Related to NAVAL PROVING GROUND VA.0-01-1 - DOE Letter; Fiore to Schafer; Referral of DOD or Former

70

A stochastic programming approach for optimal microgrid economic operation under uncertainty using 2m?+?1 point estimate method  

Science Journals Connector (OSTI)

By increasing concern over climate change and the security of energy supplies wind power and photovoltaic are emerging as important sources of electrical energy throughout the world. The wind speed at a given location is continuously varying. There are changes in the annual mean wind speed from year to year (annual) changes with season (seasonal) with passing weather systems (synoptic) on a daily basis (diurnal) and from second to second (turbulence). Common sense tells us that irradiation varies regionally with the changing seasons and hourly with the daily variation of the sun's evaluation. This paper proposes a new method for optimal management of MicroGrids under uncertain environments. In this study the 2m?+?1 point estimate method is used to model the uncertainty in the load demands the market prices and the electric power generation of the wind farms and the photovoltaic systems. The Weibull Beta and normal distributions are used to handle the uncertain input variables in this study. Moreover a Self-Adaptive Bee Swarm Optimization algorithm is presented to achieve an optimal-operational planning with regard to the cost minimization. In the proposed framework four different moving patterns are suggested in order to make an adaptive and robust optimization algorithm for different problems with different fitness landscape. In the devised method each bee self-adaptively chooses one of the proposed moving patterns according to a probability model to update its position. The proposed probability model is based on the ability of each strategy to generate more optimal solutions in the past generations. The efficiency of the method is validated on a typical microgrid.

2013-01-01T23:59:59.000Z

71

Reduction of Hexavalent Chromium in Soil and Ground Water Using Zero-Valent Iron Under Batch and Semi-Batch Conditions  

Science Journals Connector (OSTI)

Chemical remediation of soil and groundwater containing hexavalent chromium (Cr(VI)) was carried out under batch and semi-batch conditions using different iron species: (Fe(II) (sulphate solution); Fe0 ...

Débora V. Franco; Leonardo M. Da Silva; Wilson F. Jardim

2009-02-01T23:59:59.000Z

72

Heat and Mass Transfer in a Wetted Thermal Insulation of hot Water Pipes Operating Under Flooding Conditions  

Science Journals Connector (OSTI)

We present the results of numerical simulation of the thermal regimes of hot water pipes under flooding conditions with account for evaporation and diffusion ... modeling thermal regimes of hot water pipes under

V. Yu. Polovnikov; E. V. Gubina

2014-09-01T23:59:59.000Z

73

The National Radio Astronomy Observatory is a facility of the National Science Foundation operated under a cooperative agreement by Associated Universities, Inc. Astronomy: The Visible and Invisible Universe  

E-Print Network [OSTI]

The National Radio Astronomy Observatory is a facility of the National Science Foundation operated under a cooperative agreement by Associated Universities, Inc. Astronomy: The Visible and Invisible Universe #12;The National Radio Astronomy Observatory is a facility of the National Science Foundation

Groppi, Christopher

74

The effect of thermal treatment on structure and surface composition of PtCo electro-catalysts for application in PEMFCs operating under automotive applications  

E-Print Network [OSTI]

characteristics of carbon-supported PtCo cathode electro-catalysts were investigated to evaluate their performance. Both catalysts showed good performance under PEMFC operation; however, the catalyst characterised, the electrochemical processes involved in PEMFCs need Pt-based electro-catalysts to occur at significant rates [3

Paris-Sud XI, Université de

75

A Stochastic Unit-Commitment Model to Estimate the Costs of Changing Power Plant Operation under High Amounts of Intermittent Wind Power  

E-Print Network [OSTI]

) a market for district heating and process heat. Time series for the wind power production rely on timeA Stochastic Unit-Commitment Model to Estimate the Costs of Changing Power Plant Operation under High Amounts of Intermittent Wind Power Integration Meibom, P.1 , Brand, H.2 , Barth, R.2 and Weber, C

76

On LHCb muon MWPC grounding  

E-Print Network [OSTI]

My goal is to study how a big MWPC system, in particular the LHCb muon system, can be protected against unstable operation and multiple spurious hits, produced by incorrect or imperfect grounding in the severe EM environment of the LHCb experiment. A mechanism of penetration of parasitic current from the ground loop to the input of the front-end amplifier is discussed. A new model of the detector cell as the electrical bridge is considered. As shown, unbalance of the bridge makes detector to be sensitive to the noise in ground loop. Resonances in ground loop are specified. Tests of multiple-point and single-point grounding conceptions made on mock-up are presented.

Kashchuk, A

2006-01-01T23:59:59.000Z

77

Performance analysis of supply and return fans for HVAC systems under different operating strategies of economizer dampers  

Science Journals Connector (OSTI)

HVAC systems and associated equipment consume a relatively large fraction of total building energy consumption, a significant portion of which is attributed to fan operation. The operation of economizer dampers when installed can cause high energy consumption in fans if they are not functioning in proper and optimal manner. This will mainly be due to the potential high pressure drops through those dampers and associated high total pressures that should be developed by supply and/or return fans. It is then necessary to ensure that a proper strategy to operate optimally the economizer dampers is implemented with minimum fan energy use. The paper examines several operation strategies of the economizer dampers and investigates their effects on the performance of both the supply and return fans in HVAC system. It also discusses a new operating strategy for economizer dampers that can lead to lower fan energy use. The strategies are evaluated by simulations for a typically existing HVAC system. Several factors such as the building locations, system characteristics, resistance in the duct where the dampers are installed, supply air temperature and economizer control, and minimum ventilation requirements are also considered during the evaluations. The results show that the way of the economizer dampers been controlled has a significant effect on fan performance and its energy use. The proposed strategy if properly implemented can provide fan energy saving in the range of 5–30%, depending mainly on the number of hours when the system operates in the free cooling mode, damper characteristics, and minimum outdoor air.

Nabil Nassif

2010-01-01T23:59:59.000Z

78

Control of a DFIG-based wind energy conversion system operating under harmonically distorted unbalanced grid voltage along with nonsinusoidal rotor injection conditions  

Science Journals Connector (OSTI)

Abstract In this study, novel hybrid proportional-integral-harmonic resonant (PI-R) controllers implemented in the both (dq)+ and rotor (?r?r) reference frames are presented to control a doubly fed induction generator (DFIG)-based wind power generation system operating simultaneously under the three conditions which are nonsinusoidal rotor voltage injection, harmonically distorted grid voltage, and unbalanced grid voltage. The contribution of this work is to present a novel control scheme implemented in the both (dq)+ and rotor (?r?r) reference frames by considering all the three mentioned conditions (no one or two of them). It will be shown that the proposed control scheme keeps the DFIG in an acceptable operation margin and furthermore, it eliminates all harmonics and pulsations components from the stator and the rotor circuits when the DFIG operates under harmonically distorted unbalanced grid voltage along with quasi-sine rotor injection conditions. The proposed control scheme is simulated in MATLAB/Simulink and simulated results are presented to validate the theoretical results. Although this work is carried out under the three mentioned conditions and other related works have been reported under only one condition, comparison between the results of this work and other works is performed to prove the excellent performances of the proposed control scheme.

Hassan Fathabadi

2014-01-01T23:59:59.000Z

79

A novel control strategy of a distributed generator operating in seven modes for ancillary services under grid faults  

Science Journals Connector (OSTI)

This study was interested in a renewable distributed generator (RDG) made up of a wind turbine used as a principal source and a supercapacitor (SC) considered as a storage system. The studied RDG is associated with loads to constitute a micro-grid (MG) which can operate in grid connected mode, stand alone mode or synchronization mode. The objective of this work is to investigate a novel control scheme for MG integrated into power electrical system in order to maintain the voltage and the frequency of the grid in an allowable range and to ensure the continuity of power supply in case of grid failure. This control strategy made up of two parts: the first one is the power management algorithm used to detect islanding in case of defect and to monitor the RDG into seven operating modes. The second one is the droop control used to control the exported or imported active and reactive powers transferred with the grid ensuring its stability by adjusting the frequency and amplitude of its output voltage. The system is simulated using MATLAB software and results are provided in order to show the feasibility of this control strategy.

Mouna Rekik; Achraf Abdelkafi; Lotfi Krichen

2013-01-01T23:59:59.000Z

80

Case study of underground pipe ground coupled heat pump system  

Science Journals Connector (OSTI)

Aiming to give some advices on the ground coupled heat pump system design in Sichuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year,...

Min Zheng ??; Bai-yi Li ???; Zheng-yong Qiao ???

2012-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Experimental investigation of DI diesel engine operating with eucalyptus biodiesel/natural gas under dual fuel mode  

Science Journals Connector (OSTI)

Abstract With the gradual depletion of petroleum and environmental degradation, intensive research activity has been addressed to the utilization of alternative fuels in internal combustion engines. In the present work, an experimental investigation is carried out to study the effect of eucalyptus biodiesel and natural gas under dual fuel combustion mode on the performance and the exhaust emissions of a single cylinder DI diesel engine. The natural gas (NG) is inducted with the intake air through the inlet manifold. The liquid pilot fuel (eucalyptus biodiesel or diesel fuel) is injected into the combustion chamber to cover approximately 10% of the maximum power output. Then, keeping constant the pilot fuel flow rate, the power output is further increased using only natural gas. The combustion characteristics (cylinder pressure, ignition delay and heat release rate), performance and exhaust emissions of the dual fuel mode (NG–diesel fuel and NG–biodiesel) are compared with those of conventional diesel engine mode at various load conditions. The combustion analysis has shown that biodiesel as pilot fuel exhibits similar pressure–time history, with highest peak, as diesel fuel in conventional and dual fuel modes. The performance and pollutant emission results show that, compared to diesel fuel in dual fuel mode, the use of eucalyptus biodiesel as pilot fuel reduces the high emission levels of unburned hydrocarbon (HC), carbon monoxide (CO) and carbon dioxide (CO2) particularly at high engine loads. However this is accompanied by an increase in the brake specific fuel consumption (BSFC) and the nitrogen oxide (NOx) emissions, which can be explained by the lower calorific value and the oxygen presence in the molecule of the eucalyptus biodiesel, respectively.

L. Tarabet; K. Loubar; M.S. Lounici; K. Khiari; T. Belmrabet; M. Tazerout

2014-01-01T23:59:59.000Z

82

Solid waste retrieval. Phase 1, Operational basis  

SciTech Connect (OSTI)

This Document describes the operational requirements, procedures, and options for execution of the retrieval of the waste containers placed in buried storage in Burial Ground 218W-4C, Trench 04 as TRU waste or suspect TRU waste under the activity levels defining this waste in effect at the time of placement. Trench 04 in Burial Ground 218W-4C is totally dedicated to storage of retrievable TRU waste containers or retrievable suspect TRU waste containers and has not been used for any other purpose.

Johnson, D.M.

1994-09-30T23:59:59.000Z

83

Dynamic Analysis of Hybrid Energy Systems under Flexible Operation and Variable Renewable Generation -- Part I: Dynamic Performance Analysis and Part II: Dynamic Cost  

SciTech Connect (OSTI)

Dynamic analysis of hybrid energy systems (HES) under flexible operation and variable renewable generation is considered in order to better understand various challenges and opportunities associated with the high system variability arising from the integration of renewable energy into the power grid. Unique consequences are addressed by devising advanced HES solutions in which multiple forms of energy commodities, such as electricity and chemical products, may be exchanged. Dynamic models of various unit operations are developed and integrated within two different HES options. One HES option, termed traditional, produces electricity only and consists of a primary heat generator (PHG) (e.g., a small modular reactor), a steam turbine generator, a wind farm, and a battery storage. The other HES option, termed advanced, includes not only the components present in the traditional option but also a chemical plant complex to repurpose excess energy for non-electricity services, such as for the production of chemical goods (e.g., transportation fuel). In either case, a given HES is connected to the power grid at a point of common coupling and requested to deliver a certain electricity generation profile as dictated by a regional power grid operator based on a predicted demand curve. Dynamic analysis of these highly-coupled HES are performed to identify their key dynamical properties and limitations and to prescribe solutions for best managing and mitigating the high variability introduced from incorporating renewable energy into the energy mix. A comparative dynamic cost analysis is also conducted to determine best HES options. The cost function includes a set of metrics for computing fixed costs, such as fixed operations and maintenance (O&M) and overnight capital costs, and also variable operational costs, such as cost of variability, variable O&M cost, and cost of environmental impact, together with revenues. Assuming different options for implementing PHG (e.g., natural gas, coal, nuclear), preliminary results identify the level of renewable penetration at which a given advanced HES option (e.g., a nuclear hybrid) becomes increasingly more economical than a traditional electricity-only generation solution. Conditions are also revealed under which carbon resources may be better utilized as carbon sources for chemical production rather than as combustion material for electricity generation.

Humberto E. Garcia; Amit Mohanty; Wen-Chiao Lin; Robert S. Cherry

2013-04-01T23:59:59.000Z

84

Ground water and energy  

SciTech Connect (OSTI)

This national workshop on ground water and energy was conceived by the US Department of Energy's Office of Environmental Assessments. Generally, OEA needed to know what data are available on ground water, what information is still needed, and how DOE can best utilize what has already been learned. The workshop focussed on three areas: (1) ground water supply; (2) conflicts and barriers to ground water use; and (3) alternatives or solutions to the various issues relating to ground water. (ACR)

Not Available

1980-11-01T23:59:59.000Z

85

Direct observation of bias-dependence potential distribution in metal/HfO{sub 2} gate stack structures by hard x-ray photoelectron spectroscopy under device operation  

SciTech Connect (OSTI)

Although gate stack structures with high-k materials have been extensively investigated, there are some issues to be solved for the formation of high quality gate stack structures. In the present study, we employed hard x-ray photoelectron spectroscopy in operating devices. This method allows us to investigate bias dependent electronic states, while keeping device structures intact. Using this method, we have investigated electronic states and potential distribution in gate metal/HfO{sub 2} gate stack structures under device operation. Analysis of the core levels shifts as a function of the bias voltage indicated that a potential drop occurred at the Pt/HfO{sub 2} interface for a Pt/HfO{sub 2} gate structure, while a potential gradient was not observed at the Ru/HfO{sub 2} interface for a Ru/HfO{sub 2} gate structure. Angle resolved photoelectron spectroscopy revealed that a thicker SiO{sub 2} layer was formed at the Pt/HfO{sub 2} interface, indicating that the origin of potential drop at Pt/HfO{sub 2} interface is formation of the thick SiO{sub 2} layer at the interface. The formation of the thick SiO{sub 2} layer at the metal/high-k interface might concern the Fermi level pinning, which is observed in metal/high-k gate stack structures.

Yamashita, Y. [National Institute for Materials Science, Advanced Electric Materials Center, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); National Institute for Materials Science, NIMS Beamline Station at SPring-8, 1-1-1 Kôto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Yoshikawa, H.; Kobayashi, K. [National Institute for Materials Science, NIMS Beamline Station at SPring-8, 1-1-1 Kôto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Chikyo, T. [National Institute for Materials Science, Advanced Electric Materials Center, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan)

2014-01-28T23:59:59.000Z

86

Consulting, Construction and Operating Results of a Full-Scale Biotechnological Plant for the Oxidation of Iron and Manganese with Simultaneous Elimination of Volatile Chlorinated Hydrocarbons from Ground Water  

Science Journals Connector (OSTI)

The ground water in the south part of Hannover, known ... Südstadt”, is partially polluted with volatile chlorinated hydrocarbons (C1HC). This contamination originated from a ... the factory stands as well as the...

V. Quentmeier; M. Saake

1990-01-01T23:59:59.000Z

87

Economics of design and operation of overhead electric distribution systems  

E-Print Network [OSTI]

failures where bare conductors have been used, than on lines under the same operating conditions built of weather-proof conductor. k9 The area of the conductor exoosed to viind and ice, loading nas been re- duced by, omitting the insulation without... ? dead end, galvanized, zith cotter key. This clevis must, fit both $506 and O. B. X. H. strain insulators under 10, 000 pound tension. 19. Connectors ? 3 ? bolt, solderless, bronze clamp. 20. Connectors ? aluminum, 2" clamp. 21. Ground rods...

Cox, Carl Clarence

2012-06-07T23:59:59.000Z

88

Ground Vibration Measurement  

Science Journals Connector (OSTI)

Measurement of ground vibration is important for checking of amplitudes of ... confirmation of efficiency of control measures of ground vibration. The properties of measuring instruments used can affect the resul...

Dr. Milutin Srbulov

2010-01-01T23:59:59.000Z

89

Intermittent experimental study of a vertical ground source heat pump system  

Science Journals Connector (OSTI)

Abstract In this paper, the intermittent experiment of a vertical ground source heat pump (GSHP) system is investigated and the corresponding geo-temperature variations are studied. The performance of the GSHP system under intermittent operation and the comparisons of different intermittent modes are presented in the paper. The parameters of soil backfill material, air temperature and inlet volume flow rate are also investigated. Experimental results suggest that, due to the recovery in ground thermal energy in intermittent time, the heat exchange rate and the operation performance coefficient (COP) of the heat pump increases, and the compressor power decreases in the successive working. But an insufficient soil recovery time leads to a rapid decline of the performance parameters and the soil temperature. The temperature transports faster under large soil thermal conductivity conditions and the soil temperature decreases more quickly and recovers more slowly with larger inlet flow rate and lower weather temperature for different soil thermal diffusivities. Through multiple nonlinear regression analysis, a curve formula can be fitted to predict the soil temperature variations under intermittent operation of the ground source heat pump in winter, Dalian. It can be found that the soil temperature increases at an exponential function with each factor.

Yan Shang; Ming Dong; Sufen Li

2014-01-01T23:59:59.000Z

90

Little Climates -- Weather Just Above The Ground  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Weather Just Above The Ground Weather Just Above The Ground Nature Bulletin No. 481-A February 17, 1973 Forest Preserve District of Cook County George W, Dunne, President Roland F. Eisenbeis, Supt. of Conservation LITTLE CLIMATES -- Weather Just Above the Ground In a previous bulletin we talked about little climates, underground, resulting from weather conditions in the soil. Just above the ground there is another "little climate" equally important. We frequently see evidences of it without realizing how and why they were produced. Just above the earth, there lies a narrow layer of changeable weather that is affected at both surfaces by its mighty neighbors: the land below and the restless air in the atmosphere above it. Under the spell of gravity, it clings to the ground in spite of all but the swiftest winds. In this layer there are special weather conditions overlooked by nearly everyone.

91

Substation grounding optimization.  

E-Print Network [OSTI]

??Substation grounding is a critical part of the overall electric power system. It is designed to not only provide a path to dissipate electric currents… (more)

Balev, Vadim

2014-01-01T23:59:59.000Z

92

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 3, is a users manual and an installation and validation manual for the computer program SGSYS (Substation Grounding SYStem Analysis Program). This program analyzes the substation ground field given the total electric current injected into the ground field and the design of the grounding system. Standard outputs of the program are (1) total ground resistance, (2) step voltage, (3) touch voltage, (4) voltages on a grid of points, (5) voltage profile along straight lines, (6) transfer voltages, (7) ground potential rise, (8) body currents, (9) step voltage profile along straight lines, and (10) touch voltage profile along straight lines. This program can be utilized in an interactive or batch mode. In the interactive mode, the user defines the grounding system geometry, soil parameters, and output requests interactively, with the use of a user friendly conversational program. The users manual describes data requirements and data preparation procedures. An appendix provides forms which facilitate data collection procedures. The installation and validation manual describes the computer files which make up the program SGSYS and provides a test case for validation purposes.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

93

Petroleum contaminated ground-water: Remediation using activated carbon  

Science Journals Connector (OSTI)

Ground-water contamination resulting from the leakage of crude oil and refined petroleum products during extraction and processing operations is a serious and a growing environmental problem in Nigeria. Consequently, a study of the use of activated carbon (AC) in the clean up was undertaken with the aim of reducing the water contamination to a more acceptable level. In the experiments described, crude-oil contamination of ground water was simulated under laboratory conditions using ground-water samples collected from existing hand-dug wells at Eagle Island, Port Harcourt, Nigeria. Different masses of the absorbent (i.e., activated carbon) were then added to the samples of ground water. The so treated water samples were left to equilibrate for 7 days, after which the total petroleum hydrocarbon (TPH) contents of the samples were measured. Adsorption isotherms were derived for the two forms of activated carbon used, namely granular activated-carbon (GAC) and powdered activated-carbon (PAC). Results of the TPH analyses showed that activated carbon is an excellent means for the stripping-off of the contaminant: there were decreases in contaminant concentration from an initial concentration of 9304.70 mg/l to average final concentrations of 361.00 and 12.37 mg/l, that is, 96% and 99.9% resulting from the same amounts of GAC and PAC applications respectively. The results of this study revealed that the powdered form of AC would be very effective in the remediation of petroleum-hydrocarbon contaminated ground water and its use is therefore recommended.

M.J. Ayotamuno; R.B. Kogbara; S.O.T. Ogaji; S.D. Probert

2006-01-01T23:59:59.000Z

94

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. It can be used to compute transient ground potential rise due to lightning or switching, and the ground impedance (i.e. resistance and reactance) at specified frequencies. This report, Volume 4, is a users manual and an installation and validation manual for the computer program TGRND (Transient GRouNDing System Analysis Program). This program computes transient ground potential rise resulting from lightning, switching, or other transient electric currents injected to a grounding system. The program also computes the impedance (i.e. resistance and reactance) of a grounding system as a function of frequency. This program can be utilized in an interactive or batch mode. The users manual describes data requirements and data preparation procedures. The installation and validation manual describes the computer files which make up the program TGRND and provides a test case for validation purposes.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

95

Definition: Ground Source Heat Pumps | Open Energy Information  

Open Energy Info (EERE)

Pumps Pumps Jump to: navigation, search Dictionary.png Ground Source Heat Pumps A Ground Source Heat Pump is a central building heating and/or cooling system that takes advantage of the relatively constant year-round ground temperature to pump heat to or from the ground.[1][2][3] View on Wikipedia Wikipedia Definition A geothermal heat pump or ground source heat pump (GSHP) is a central heating and/or cooling system that pumps heat to or from the ground. It uses the earth as a heat source (in the winter) or a heat sink (in the summer). This design takes advantage of the moderate temperatures in the ground to boost efficiency and reduce the operational costs of heating and cooling systems, and may be combined with solar heating to form a geosolar system with even greater efficiency. Ground source heat pumps

96

Ground Motion Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2nd Advanced ICFA Beam Dynamics Workshop 2nd Advanced ICFA Beam Dynamics Workshop on Ground Motion in Future Accelerators November 6 - 9, 2000 SLAC Coordinators: Andrei Seryi & Tor Raubenheimer Proceedings Updated June 26, 2001 Agenda and Presentations Workshop photos Summaries Useful links Poster Goals Introduction to the problems Structure Registration Registered participants Committees Location, Accommodations and Travel Workshop on Ground Motion in Future Accelerators A workshop was held at SLAC that was devoted to ground motion and its effects on future accelerators. Ground motion and vibration can be a limiting effect in synchrotron light sources, hadron circular colliders, and electron/positron linear colliders. Over the last several years, there has been significant progress in the understanding of the ground motion and its effects, however, there are

97

Closure Operators and Galois Connections 1. A collection C of subsets of a set A is a closure system if it is closed under arbitrary intersections  

E-Print Network [OSTI]

(C(B)). Show : For every closure system C, C(B) = {M|M B, M C} is a closure operator, and for every closure operator C, the system C = {M|M = C(M)} is a closure system and this defines a bijection between closure systems and closure operators. 2. Let (S, ) and (T, ) be posets. A pair (g, d) of functions g : S T, d

Kaiser, Klaus

98

Hanford Site environmental data for calendar year 1990 -- Ground water  

SciTech Connect (OSTI)

This report tabulates ground-water radiological and chemical data for calendar year 1990 by the Ground-Water Surveillance Project, reported Resource Conservation and Recovery Act (RCRA) Monitoring, and Operational Monitoring. The Ground-Water Surveillance Project is conducted by the Pacific Northwest Laboratory and the RCRA and Operational Monitoring Projects are conducted by the Westinghouse Hanford Company. This document supplements the reports Hanford Site Ground-Water Monitoring for 1990 (Evans et al. 1992) and mental Report for Calendar Year 1990 (Woodruff and Hanf 1991). The data listings provided here were generated from the Hanford Environmental Information System database.

Dresel, P.E.; Bates, D.J.; Merz, J.K.

1993-03-01T23:59:59.000Z

99

Assessment of ground subsidence using GIS and the weights-of-evidence model  

Science Journals Connector (OSTI)

The weights-of-evidence model, one of the Bayesian probability models was applied in evaluating a ground subsidence spatial hazard near abandoned underground coal mines (AUCMs) at Magyori area, Samcheok City in Korea using GIS. Using ground subsidence location and a spatial database containing information such as mining tunnel, borehole, topography, geology, and land use, the weights-of-evidence model was applied to calculate each relevant factor's rating for the Magyori area in Korea. Seven major factors controlling or related to ground subsidence were determined from the probability analysis of the existing ground subsidence area; depth of drift and distance from drift from the mining tunnel map, slope gradient obtained from the topographical map, ground water level and permeability from borehole data, geology and land use. Tests of conditional independence were performed for the selection of factors, allowing 6 combinations of factors to be analyzed. For the analysis of mapping ground subsidence spatial hazard, the contrast values, W+ and W?, of each factor's rating were overlaid spatially. The results of the analysis were validated using receiver operating characteristic (ROC) with the previous ground subsidence locations. In the case of all factor used, the area under the ROC curve (AUC) showed 0.9667, which corresponds to an accuracy of 96.67%. In the case of the combinations, the case of distance from drift, depth of ground water and land use used, showed the 90.71% (AUC: 0.9071) accuracy which is the best result produced in this analysis. The results can be used for hazard prevention and land-use planning near AUCM areas.

Hyun-Joo Oh; Saro Lee

2010-01-01T23:59:59.000Z

100

Engine ground demonstration test approach  

SciTech Connect (OSTI)

The hardware portion of the current phase of the Integrated Solar Upper Stage (ISUS) program culminates in a system ground demonstration test. The potential application of ISUS technology to a wide array of future missions complicates the process of selecting from among demonstration system design options and test approaches. The approach to this system demonstration has been to maximize system technology readiness level for the entire array of potential missions within the constraints of the program. To this end, system design and test operations planning has been carried out with a premium on demonstrating those elements of the system common to all missions. In addition, test planning has been managed to allow margin for testing those portions of the system envelope needed to confirm acceptable operation for scenarios within the mission set that are specific to a given mission or mission type. Examples drawn from the specific Engine Ground Demonstration (EGD) design selections are used to illuminate this approach, with the result that the EGD system design is not only described, but the reasons for its particular characteristics are made evident.

Kudija, C.T. [Rockwell Aerospace, Canoga Park, CA (United States). Rocketdyne Div.

1996-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Ground Water Management Act (Virginia) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Ground Water Management Act (Virginia) Ground Water Management Act (Virginia) Ground Water Management Act (Virginia) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Municipal/Public Utility Nonprofit Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Tribal Government Utility Savings Category Water Buying & Making Electricity Home Weatherization Program Info State Virginia Program Type Environmental Regulations Siting and Permitting Provider Virginia Department of Environmental Quality Under the Ground Water Management Act of 1992, Virginia manages ground water through a program regulating the withdrawals in certain areas called

102

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 2, is a users manual and an installation and validation manual for the computer program SMECC (Substation Maximum Earth Current Computation Program). This program analyzes the electric current distribution among grounded structures inside and outside a substation for different fault conditions. The fault conditions are automatically selected by the program, or they may be specified by the user, or both. The fault condition resulting in maximum substation earth current is identified and reported. Data requirements for this program are: ground impedance, transformer data, transmission line data, transmission line grounding impedances, etc. The program provides four types of standard outputs: (1) a report of voltages and current flow in the unfaulted system, (2) a brief report of the maximum ground potential rise (worst fault condition), (3) a summary report of all fault conditions which have been analyzed by the program, and (4) a detailed report of voltages and current flow for a selected set of fault conditions.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

103

Semiconductor converters of electric energy electromagnetic and electromechanical processes in an electric drive under frequency converter parallel operation to induction motor  

Science Journals Connector (OSTI)

The processes occurring in the two PWM-controlled frequency converters operating in parallel to an induction motor in the high-power electric drive’s start and self-start modes ... current consumed from the suppl...

D. V. Belyaev; A. M. Veinger; G. B. Lazarev…

2007-05-01T23:59:59.000Z

104

Cleanup Verification Package for the 618-8 Burial Ground  

SciTech Connect (OSTI)

This cleanup verification package documents completion of remedial action for the 618-8 Burial Ground, also referred to as the Solid Waste Burial Ground No. 8, 318-8, and the Early Solid Waste Burial Ground. During its period of operation, the 618-8 site is speculated to have been used to bury uranium-contaminated waste derived from fuel manufacturing, and construction debris from the remodeling of the 313 Building.

M. J. Appel

2006-08-10T23:59:59.000Z

105

Development of an integrated building load and ground source heat pump model to assess heat pump and ground loop design and performance in a commercial office building.  

E-Print Network [OSTI]

??Ground source heat pumps (GSHPs) offer an efficient method for cooling and heating buildings, reducing energy usage and operating cost. In hot, arid regions such… (more)

Blair, Jacob Dale

2014-01-01T23:59:59.000Z

106

Insights from the Nogales Predator Crash for the Integration of UAV's into the US National Airspace System under FAA Interim Operational Approval Guidance 08-01  

E-Print Network [OSTI]

Insights from the Nogales Predator Crash for the Integration of UAV's into the US National Airspace Traffic Management. Abstract In April 2006, an Unmanned Aerial Vehicle (UAV) crashed near Nogales, Arizona whether a process that enables the same agency to act as regulator and operator of a UAV can be justified

Johnson, Chris

107

Ground-Based Microwave Radiometer Measurements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ground-Based Microwave Radiometer Measurements Ground-Based Microwave Radiometer Measurements and Radiosonde Comparisons During the WVIOP2000 Field Experiment D. Cimini University of L'Aquila L'Aquil, Italy E. R. Westwater Cooperative Institute for Research in the Environmental Sciences University of Colorado National Oceanic and Atmospheric Administration Environmental Technology Laboratory Boulder, Colorado Y. Han Science System Applications National Aeronautics Space Administration Goddard Space Flight Center Greenbelt, Maryland S. Keihm Jet Propulsion Laboratory California Institute of Technology Pasadena, California Introduction During September to October 2000, a water vapor intensive operational period (WVIOP) was conducted at the Atmospheric Radiation Measurement (ARM) Program's Southern Great Plains (SGP) Cloud and

108

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 5, is an applications guide of the three computer programs. SOMIP, SMECC, and SGSYS, for the purpose of designing a safe substation grounding system. The applications guide utilizes four example substation grounding systems for the purpose of illustrating the application of the programs, SOMIP, SMECC, and SGSYS. The examples are based on data provided by four contributing utilities, namely, Houston Lighting and Power Company, Southern Company Services, Puget Sound Power and Light Company, and Arizona Public Service Company. For the purpose of illustrating specific capabilities of the computer programs, the data have been modified. As a result, the final designs of the four systems do not necessarily represent actual grounding system designs by these utilities. The example system 1 is a 138 kV/35 kV distribution substation. The example system 2 is a medium size 230 kV/115 kV transmission substation. The third example system is a generation substation while the last is a large 525 kV/345 kV/230 kV transmission substation. The four examples cover most of the practical problems that a user may encounter in the design of substation grounding systems.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

109

Damage and collapse of double hull tankers in groundings  

SciTech Connect (OSTI)

This paper will discuss and analyze the mechanics of ships in groundings on rock. A damage estimate model in grounding of ships is proposed. The accuracy and applicability of the model are verified by a comparison of experimental results. The progressive collapse analysis of damaged hull sections, under vertical bending moments by use of the ALPS/ISUM computer code, is described. The procedure is applied to grounding simulation of a double hull tanker with transverseless system.

Paik, J.K.; Lee, T.K. [Pusan National Univ. (Korea, Republic of). Dept. of Naval Architecture and Ocean Engineering

1995-12-31T23:59:59.000Z

110

Cleanup Verification Package for the 118-F-1 Burial Ground  

SciTech Connect (OSTI)

This cleanup verification package documents completion of remedial action for the 118-F-1 Burial Ground on the Hanford Site. This burial ground is a combination of two locations formerly called Minor Construction Burial Ground No. 2 and Solid Waste Burial Ground No. 2. This waste site received radioactive equipment and other miscellaneous waste from 105-F Reactor operations, including dummy elements and irradiated process tubing; gun barrel tips, steel sleeves, and metal chips removed from the reactor; filter boxes containing reactor graphite chips; and miscellaneous construction solid waste.

E. J. Farris and H. M. Sulloway

2008-01-10T23:59:59.000Z

111

Substation grounding programs  

SciTech Connect (OSTI)

The five volume report comprises the user manual, installation, and validation manual and an applications guide for the SGA (Substation Grounding Analysis) software package. SGA consists of four computer programs: (1) SOMIP, (2) SMECC, (3) SGSYS, and (4) TGRND. The first three programs provide a comprehensive analysis tool for the design of substation grounding systems to meet safety standards. The fourth program, TGRND, provides a state of the art analysis tool for computing transient ground potential rise and ground system impedance. This part of the report, Volume 1, is a users manual and an installation and validation manual for the computer program SOMIP (SOil Measurement Interpretation Program). This program computes the best estimate of the parameters of a two layer soil model from usual soil resistivity measurements. Four pin or three pin soil measurements can be accommodated. In addition, it provides error bounds on the soil parameters for a given confidence level. The users manual describes data requirements and data preparation procedures. The installation and validation manual describes the computer files which make up the program SOMIP and provides two test cases for validation purposes. 4 refs.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). School of Electrical Engineering)

1992-05-01T23:59:59.000Z

112

SPECTRAL THEORY FOR JACOBI OPERATORS A Dissertation  

E-Print Network [OSTI]

of a given semi-bounded back- ground Jacobi operator and the double commutation method which inserts eigen- values into arbitrary spectral gaps. Moreover, we prove unitary equivalence of the commuted operators

Teschl, Gerald

113

Rational analysis of mass, momentum, and heat transfer phenomena in liquid storage tanks under realistic operating conditions: 2. Application to a feasibility study  

Science Journals Connector (OSTI)

This is the second part of a two-part paper that deals with modelling the thermal performances of storage tanks of liquid water coupled with solar-assisted heatpump systems. The computer code THESTA, described in detail in the first part, has been applied to compare configurations which differ from one another in the distribution and thickness of the insulating panels. These numerical experiments show very clearly the capability of the code in simulating realistic operating conditions. The validity of the present release is also discussed. The results obtained have been assumed to be a reliable theoretical support to the definition of the features of the storage device of a pilot plant.

F. Parrini; S. Vitale; L. Castellano

1992-01-01T23:59:59.000Z

114

New balanced mode of operation for TMX-U  

SciTech Connect (OSTI)

Under certain, esily reproduced conditions during the January, 1984, period of Tandem Mirror Experiment-Upgrade (TMX-U) operation, relatively dense (approx. 2 x 10/sup 12/ central cell density), well confined plasmas (phi/sub c//T/sub c/ approx. = 1.7 to 2.7) have been produced. Under these conditions, the central cell potential appeared to be near ground. We present a scenario to explain this plugging and the axial profile. Simple experimental tests in the future should show whether or not the implied potential profile is correct.

Nexsen, W.E.

1985-01-30T23:59:59.000Z

115

Verification of Active and Passive Ground-Water Contamination Remediation Efforts  

Science Journals Connector (OSTI)

The verification of ground-water contamination remediation efforts requires thorough documentation of subsurface conditions ... comprehensive approach to the design and operation of remediation efforts with an em...

M. J. Barcelona

1995-01-01T23:59:59.000Z

116

Land use requirements for ground-mounted solar power facilities. | OpenEI  

Open Energy Info (EERE)

Land use requirements for ground-mounted solar power facilities. Land use requirements for ground-mounted solar power facilities. Dataset Summary Description This dataset is part of a larger internal dataset at the National Renewable Energy Laboratory (NREL) that explores various characteristics of large solar electric (both PV and CSP) facilities around the United States. This dataset focuses on the land use characteristics for solar facilities that are either under construction or currently in operation. Source Land-Use Requirements for Solar Power Plants in the United States Date Released June 25th, 2013 (5 months ago) Date Updated Unknown Keywords acres area average concentrating solar power csp Density electric hectares km2 land land requirements land use land-use mean photovoltaic photovoltaics PV solar statistics Data application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon Master Solar Land Use Spreadsheet (xlsx, 1.5 MiB)

117

Ground Squirrels and Gophers  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Squirrels and Gophers Squirrels and Gophers Nature Bulletin No. 224-A April 2, 1966 Forest Preserve District of Cook County Seymour Simon, President Roland F. Eisenbeis, Supt. of Conservation GROUND SQUIRRELS AND GOPHERS On sunny summer days, a dusty-colored animal with yellowish and brown stripes, about the size of a small rat, often may be noticed creeping through the grass of prairies, pastures, golf courses or lawns. Watch him. He pauses every few feet to sit up, look and listen for a moment. Nervous and timid, he crouches low at every distant sound or passing shadow. Startle him and he scurries away, and then may suddenly halt and freeze, bolt upright, as stiff and straight as a stake driven in the ground. If approached, he gives a loud shrill trilling whistle and, with a flip of his tail, pops out of sight. Watch that spot closely and, in less than a minute, a snaky head appears. Be quiet. He has many enemies above ground and he also has a lot of curiosity. Presently he sits up upon his haunches again.

118

Field Test of High Efficiency Residential Buildings with Ground-source and Air-source Heat Pump Systems  

SciTech Connect (OSTI)

This paper describes the field performance of space conditioning and water heating equipment in four single-family residential structures with advanced thermal envelopes. Each structure features a different, advanced thermal envelope design: structural insulated panel (SIP); optimum value framing (OVF); insulation with embedded phase change materials (PCM) for thermal storage; and exterior insulation finish system (EIFS). Three of the homes feature ground-source heat pumps (GSHPs) for space conditioning and water heating while the fourth has a two-capacity air-source heat pump (ASHP) and a heat pump water heater (HPWH). Two of the GCHP-equipped homes feature horizontal ground heat exchange (GHX) loops that utillize the existing foundation and utility service trenches while the third features a vertical borehole with vertical u-tube GHX. All of the houses were operated under the same simulated occupancy conditions. Operational data on the house HVAC/Water heating (WH) systems are presented and factors influencing overall performance are summarized.

Ally, Moonis Raza [ORNL] [ORNL; Munk, Jeffrey D [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL

2011-01-01T23:59:59.000Z

119

Ground Water Recovery and Treatment  

Science Journals Connector (OSTI)

Until the environmental revolution, the only ground water that was routinely treated to remove contamination was the impacted ground water that was extracted for beneficial use. With ... the recognition that cont...

Tie Li Ph.D.; Raaj U. Patel P.G.; David K. Ramsden Ph.D.…

2003-01-01T23:59:59.000Z

120

Ground-source Heat Pumps Applied to Commercial Buildings  

SciTech Connect (OSTI)

Ground-source heat pumps can provide an energy-efficient, cost-effective way to heat and cool commercial facilities. While ground-source heat pumps are well established in the residential sector, their application in larger, commercial-style, facilities is lagging, in part because of a lack of experience with the technology by those in decision-making positions. Through the use of a ground-coupling system, a conventional water-source heat pump design is transformed to a unique means of utilizing thermodynamic properties of earth and groundwater for efficient operation throughout the year in most climates. In essence, the ground (or groundwater) serves as a heat source during winter operation and a heat sink for summer cooling. Many varieties in design are available, so the technology can be adapted to almost any site. Ground-source heat pump systems can be used widely in commercial-building applications and, with proper installation, offer great potential for the commercial sector, where increased efficiency and reduced heating and cooling costs are important. Ground-source heat pump systems require less refrigerant than conventional air-source heat pumps or air-conditioning systems, with the exception of direct-expansion-type ground-source heat pump systems. This chapter provides information and procedures that an energy manager can use to evaluate most ground-source heat pump applications. Ground-source heat pump operation, system types, design variations, energy savings, and other benefits are explained. Guidelines are provided for appropriate application and installation. Two case studies are presented to give the reader a sense of the actual costs and energy savings. A list of manufacturers and references for further reading are included for prospective users who have specific or highly technical questions not fully addressed in this chapter. Sample case spreadsheets are provided in Appendix A. Additional appendixes provide other information on the ground-source heat pump technology.

Parker, Steven A.; Hadley, Donald L.

2009-07-14T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Ground-Source Heat Pumps Applied to Commercial Buildings  

SciTech Connect (OSTI)

Ground-source heat pumps can provide an energy-efficient, cost-effective way to heat and cool commercial facilities. While ground-source heat pumps are well established in the residential sector, their application in larger, commercial-style, facilities is lagging, in part because of a lack of experience with the technology by those in decision-making positions. Through the use of a ground-coupling system, a conventional water-source heat pump design is transformed to a unique means of utilizing thermodynamic properties of earth and groundwater for efficient operation throughout the year in most climates. In essence, the ground (or groundwater) serves as a heat source during winter operation and a heat sink for summer cooling. Many varieties in design are available, so the technology can be adapted to almost any site. Ground-source heat pump systems can be used widely in commercial-building applications and, with proper installation, offer great potential for the commercial sector, where increased efficiency and reduced heating and cooling costs are important. Ground-source heat pump systems require less refrigerant than conventional air-source heat pumps or air-conditioning systems, with the exception of direct-expansion-type ground-source heat pump systems. This chapter provides information and procedures that an energy manager can use to evaluate most ground-source heat pump applications. Ground-source heat pump operation, system types, design variations, energy savings, and other benefits are explained. Guidelines are provided for appropriate application and installation. Two case studies are presented to give the reader a sense of the actual costs and energy savings. A list of manufacturers and references for further reading are included for prospective users who have specific or highly technical questions not fully addressed in this chapter. Sample case spreadsheets are provided in Appendix A. Additional appendixes provide other information on the ground-source heat pump technology.

Parker, Steven A.; Hadley, Donald L.

2006-12-31T23:59:59.000Z

122

Photovoltaic ground fault and blind spot electrical simulations.  

SciTech Connect (OSTI)

Ground faults in photovoltaic (PV) systems pose a fire and shock hazard. To mitigate these risks, AC-isolated, DC grounded PV systems in the United States use Ground Fault Protection Devices (GFPDs), e.g., fuses, to de-energize the PV system when there is a ground fault. Recently the effectiveness of these protection devices has come under question because multiple fires have started when ground faults went undetected. In order to understand the limitations of fuse-based ground fault protection in PV systems, analytical and numerical simulations of different ground faults were performed. The numerical simulations were conducted with Simulation Program with Integrated Circuit Emphasis (SPICE) using a circuit model of the PV system which included the modules, wiring, switchgear, grounded or ungrounded components, and the inverter. The derivation of the SPICE model and the results of parametric fault current studies are provided with varying array topologies, fuse sizes, and fault impedances. Closed-form analytical approximations for GFPD currents from faults to the grounded current carrying conductor-known as %E2%80%9Cblind spot%E2%80%9D ground faults-are derived to provide greater understanding of the influence of array impedances on fault currents. The behavior of the array during various ground faults is studied for a range of ground fault fuse sizes to determine if reducing the size of the fuse improves ground fault detection sensitivity. The results of the simulations show that reducing the amperage rating of the protective fuse does increase fault current detection sensitivity without increasing the likelihood of nuisance trips to a degree. Unfortunately, this benefit reaches a limit as fuses become smaller and their internal resistance increases to the point of becoming a major element in the fault current circuit.

Flicker, Jack David; Johnson, Jay

2013-06-01T23:59:59.000Z

123

NGWA.org Ground Water Monitoring & Remediation 31, no. 3/ Summer 2011/pages 111118 111 2011, The Author(s)  

E-Print Network [OSTI]

NGWA.org Ground Water Monitoring & Remediation 31, no. 3/ Summer 2011/pages 111­118 111 © 2011, The Author(s) Ground Water Monitoring & Remediation © 2011, National Ground Water Association. doi: 10.1111/j under- ground storage tank containing biofuel blends. Benzene is of particular concern due to its

Alvarez, Pedro J.

124

Guide to ground water remediation at CERCLA response action and RCRA corrective action sites  

SciTech Connect (OSTI)

This Guide contains the regulatory and policy requirements governing remediation of ground water contaminated with hazardous waste [including radioactive mixed waste (RMW)], hazardous substances, or pollutants/contaminants that present (or may present) an imminent and substantial danger. It was prepared by the Office of Environmental Policy and Assistance, RCRA/CERCLA Division (EH-413), to assist Environmental Program Managers (ERPMs) who often encounter contaminated ground water during the performance of either response actions under CERCLA or corrective actions under Subtitle C of RCRA. The Guide begins with coverage of the regulatory and technical issues that are encountered by ERPM`s after a CERCLA Preliminary Assessment/Site Investigation (PA/SI) or the RCRA Facility Assessment (RFA) have been completed and releases into the environment have been confirmed. It is based on the assumption that ground water contamination is present at the site, operable unit, solid waste management unit, or facility. The Guide`s scope concludes with completion of the final RAs/corrective measures and a determination by the appropriate regulatory agencies that no further response action is necessary.

NONE

1995-10-01T23:59:59.000Z

125

The LOFT Ground Segment  

E-Print Network [OSTI]

LOFT, the Large Observatory For X-ray Timing, was one of the ESA M3 mission candidates that completed their assessment phase at the end of 2013. LOFT is equipped with two instruments, the Large Area Detector (LAD) and the Wide Field Monitor (WFM). The LAD performs pointed observations of several targets per orbit (~90 minutes), providing roughly ~80 GB of proprietary data per day (the proprietary period will be 12 months). The WFM continuously monitors about 1/3 of the sky at a time and provides data for about ~100 sources a day, resulting in a total of ~20 GB of additional telemetry. The LOFT Burst alert System additionally identifies on-board bright impulsive events (e.g., Gamma-ray Bursts, GRBs) and broadcasts the corresponding position and trigger time to the ground using a dedicated system of ~15 VHF receivers. All WFM data are planned to be made public immediately. In this contribution we summarize the planned organization of the LOFT ground segment (GS), as established in the mission Yellow Book 1 . We...

Bozzo, E; Argan, A; Barret, D; Binko, P; Brandt, S; Cavazzuti, E; Courvoisier, T; Herder, J W den; Feroci, M; Ferrigno, C; Giommi, P; Götz, D; Guy, L; Hernanz, M; Zand, J J M in't; Klochkov, D; Kuulkers, E; Motch, C; Lumb, D; Papitto, A; Pittori, C; Rohlfs, R; Santangelo, A; Schmid, C; Schwope, A D; Smith, P J; Webb, N A; Wilms, J; Zane, S

2014-01-01T23:59:59.000Z

126

Operations Information  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Standards BPA Operations Information (OPI) Transmission Services operates and plans for regional and national system needs. Transmission Services coordinates system operation and...

127

Building Energy Software Tools Directory: Ground Loop Design  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ground Loop Design Ground Loop Design Ground Loop Design logo Ground Loop Design is a versatile ground source heat pump system design program that helps the trained geothermal HVAC designer/engineer size equipment, determine the correct lengths of bore or pipe required for commercial projects, optimize the piping configuration for balanced flow and optimal heat transfer, and calculate the annual and lifetime energy/operating/emissions costs associated with the design. The modular program enhances design productivity and permits flexibility in the designing process and customization based on designer preferences. It also has an English/metric conversion engine and is available in many languages, providing applicability to the widest range of equipment and customers. Screen Shots

128

Ground potential rise monitor  

DOE Patents [OSTI]

A device and method for detecting ground potential rise (GPR) comprising positioning a first electrode and a second electrode at a distance from each other into the earth. The voltage of the first electrode and second electrode is attenuated by an attenuation factor creating an attenuated voltage. The true RMS voltage of the attenuated voltage is determined creating an attenuated true RMS voltage. The attenuated true RMS voltage is then multiplied by the attenuation factor creating a calculated true RMS voltage. If the calculated true RMS voltage is greater than a first predetermined voltage threshold, a first alarm is enabled at a local location. If user input is received at a remote location acknowledging the first alarm, a first alarm acknowledgment signal is transmitted. The first alarm acknowledgment signal is then received at which time the first alarm is disabled.

Allen, Zachery W. (Mandan, ND); Zevenbergen, Gary A. (Arvada, CO)

2012-04-03T23:59:59.000Z

129

Safe Chain Saw Operation.  

E-Print Network [OSTI]

Z TA24S.7 8873 NO.1409 B-1409 SAFE CHAIN SAW OPERATION Gary S. Nelson* A chain saw is a portable power cutting machine. Used properly, it will trim or cut down trees, clear land or cut fireplace wood. Improperly used, a chain saw can... ground level , losing balance, shifting chain saw weight while cutting at or above waist level or ex periencing chain saw kickback. Often, loss of balance causes an operator to reach into the running saw blade as he grabs to steady himself. Other...

Nelson, Gary S.

1982-01-01T23:59:59.000Z

130

Monticello Mill Tailings, Operable Unit III Surface and Ground...  

Office of Legacy Management (LM)

use of the contaminated alluvial aquifer as a primary drinking water source fails, then Alternative 4 will have the greatest short-term effectiveness because it has the shortest...

131

Longevity of Emplacement Drift Ground Support Materials  

SciTech Connect (OSTI)

The purpose of this analysis is to evaluate the factors affecting the longevity of emplacement drift ground support materials and to develop a basis for the selection of materials for ground support that will function throughout the preclosure period of a potential repository at Yucca Mountain. REV 01 ICN 01 of this analysis is developed in accordance with AP-3.10Q, Analyses and Models, Revision 2, ICN 4, and prepared in accordance with the Technical Work Plan for Subsurface Design Section FY 01 Work Activities (CRWMS M&O 2001a). The objective of this analysis is to update the previous analysis (CRWMS M&O 2000a) to account for related changes in the Ground Control System Description Document (CRWMS M&O 2000b), the Monitored Geologic Repository Project Description Document, which is included in the Requirements and Criteria for Implementing a Repository Design that can be Operated Over a Range of Thermal Modes (BSC 2001), input information, and in environmental conditions, and to provide updated information on candidate ground support materials. Candidate materials for ground support are carbon steel and cement grout. Steel is mainly used for steel sets, lagging, channel, rock bolts, and wire mesh. Cement grout is only considered in the case of grouted rock bolts. Candidate materials for the emplacement drift invert are carbon steel and granular natural material. Materials are evaluated for the repository emplacement drift environment based on the updated thermal loading condition and waste package design. The analysis consists of the following tasks: (1) Identify factors affecting the longevity of ground support materials for use in emplacement drifts. (2) Review existing documents concerning the behavior of candidate ground support materials during the preclosure period. (3) Evaluate impacts of temperature and radiation effects on mechanical and thermal properties of steel. Assess corrosion potential of steel at emplacement drift environment. (4) Evaluate factors affecting longevity of cement grouts for fully grouted rock bolt system. Provide updated information on cement grout mix design for fully grouted rock bolt system. (5) Evaluate longevity of materials for the emplacement drift invert.

D.H.Tang

2001-05-30T23:59:59.000Z

132

Cleaning Up the Hanford River Corridor and Improving Site Operations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

operations * Continue River Corridor cleanup, including remediation of 618-10 Burial Ground * Continue Plutonium Finishing Plant deactivation, decommissioning and demolition *...

133

Protection Program Operations  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Order establishes requirements for the management and operation of the Department of Energy (DOE) Federal Protective Forces (FPF), Contractor Protective Forces (CPF), and the Physical Security of property and personnel under the cognizance of DOE.

2014-10-14T23:59:59.000Z

134

Probing Solid Catalysts Under Operating Conditions  

Science Journals Connector (OSTI)

...J.W., TRACING THE CONVERSION OF AURICHALCITE TO A COPPER CATALYST BY COMBINED X-RAY...synthetic variants of the mineral phase aurichalcite [Cu5, Zn,(OH)6(CO3)21...stages of the thermal treatment of the aurichalcite, no significant changes occur in the...

John Meurig Thomas; G. Neville Greaves

1994-09-16T23:59:59.000Z

135

Probing Solid Catalysts Under Operating Conditions  

Science Journals Connector (OSTI)

...3355 ( 1993 ). BACHRACH, R.Z., SYNCHROTON RAD RES 1 : ( 1992 ). BACHRACH, R.Z., SYNCHROTON RAD RES 2 : ( 1992 ). BECK, J.S...1993). 2. R. Z. Bachrach, Ed., Synchroton Radiation Re-search (Plenum, New...

John Meurig Thomas; G. Neville Greaves

1994-09-16T23:59:59.000Z

136

Department of Veterans Affairs, FONSI - Ground mounted solar photovoltaic  

Broader source: Energy.gov (indexed) [DOE]

Ground mounted solar Ground mounted solar photovoltaic power at San Joaquin National Cemetery Department of Veterans Affairs, FONSI - Ground mounted solar photovoltaic power at San Joaquin National Cemetery An Environmental Assessment (EA) has been prepared under the direction of an interdisciplinary team analyzing theproposed construction of a Photovoltaic System at the San Joaquin National Cemetery (SNC) in San Joaquin,Calofornia. CX rulemaking files More Documents & Publications Department of Veterans Affairs, FONSI - Rooftop solar PV power at Calverton National Cemetery Department of Energy Technical Support Document National Environmental Policy Act Implementing Procedures Supplement to Notice of Proposed Rulemaking Proposed Changes and Supplemental Supporting Basis

137

Posters Ground-Based Radiometric Observations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

7 7 Posters Ground-Based Radiometric Observations of Atmospheric Water for Climate Research J. B. Snider, D. A. Hazen, A. J. Francavilla, W. B. Madsen, and M. D. Jacobson National Oceanic and Atmospheric Administration Environmental Technology Laboratory Boulder, Colorado Introduction Surface-based microwave and infrared radiometers have been employed by the National Oceanic and Atmospheric Administration's Environmental Technology Laboratory (NOAA/ETL) in climate research since 1987. The ability of these systems to operate continuously and unattended for extended periods of time has provided significant new information on atmospheric water vapor and cloud liquid. These data are being employed to improve our understanding of cloud-radiation feedback mechanisms, an understanding

138

Ground Ring Of Two Dimensional String Theory  

E-Print Network [OSTI]

String theories with two dimensional space-time target spaces are characterized by the existence of a ``ground ring'' of operators of spin $(0,0)$. By understanding this ring, one can understand the symmetries of the theory and illuminate the relation of the critical string theory to matrix models. The symmetry groups that arise are, roughly, the area preserving diffeomorphisms of a two dimensional phase space that preserve the fermi surface (of the matrix model) and the volume preserving diffeomorphisms of a three dimensional cone. The three dimensions in question are the matrix eigenvalue, its canonical momentum, and the time of the matrix model.

Edward Witten

1991-08-16T23:59:59.000Z

139

EPA Final Ground Water Rule  

Broader source: Energy.gov (indexed) [DOE]

Office of Nuclear Safety and Environment Office of Nuclear Safety and Environment Nuclear Safety and Environment Information Brief HS-20-IB-2007-02 (March 2007) EPA Final Ground Water Rule Safe Drinking Water Act: National Primary Drinking Water Regulations Ground Water Rule - 40 CFR Parts 9, 141 and 142 Final Rule: 71 FR 65574 Effective Date: January 8, 2007 1 RULE SYNOPSIS On November 8, 2006, the U.S. Environmental Protection Agency (EPA) published a final Ground Water Rule (GWR) to promote increased protection against microbial pathogens that may be present in public water systems (PWSs) that use ground water sources for their supply (these systems are known as ground water systems). This Rule establishes a risk-targeted approach

140

Regional analysis of ground and above-ground climate  

SciTech Connect (OSTI)

The regional suitability of underground construction as a climate control technique is discussed with reference to (1) a bioclimatic analysis of long-term weather data for 29 locations in the United States to determine appropriate above ground climate control techniques, (2) a data base of synthesized ground temperatures for the coterminous United States, and (3) monthly dew point ground temperature comparisons for identifying the relative likelihood of condensation from one region to another. It is concluded that the suitability of earth tempering as a practice and of specific earth-sheltered design stereotypes varies geographically; while the subsurface almost always provides a thermal advantage on its own terms when compared to above ground climatic data, it can, nonetheless, compromise the effectiveness of other, regionally more important climate control techniques. Also contained in the report are reviews of above and below ground climate mapping schemes related to human comfort and architectural design, and detailed description of a theoretical model of ground temperature, heat flow, and heat storage in the ground. Strategies of passive climate control are presented in a discussion of the building bioclimatic analysis procedure which has been applied in a computer analysis of 30 years of weather data for each of 29 locations in the United States.

Not Available

1981-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Hanford Site ground-water monitoring for 1994  

SciTech Connect (OSTI)

This report presents the results of the Ground-Water Surveillance Project monitoring for calendar year 1994 on the Hanford Site, Washington. Hanford Site operations from 1943 onward produced large quantities of radiologic and chemical waste that have impacted ground-water quality on the Site. Monitoring of water levels and ground-water chemistry is performed to track the extent of contamination and trends in contaminant concentrations. The 1994 monitoring was also designed to identify emerging ground-water quality problems. The information obtained is used to verify compliance with applicable environmental regulations and to evaluate remedial actions. Data from other monitoring and characterization programs were incorporated to provide an integrated assessment of Site ground-water quality. Additional characterization of the Site`s geologic setting and hydrology was performed to support the interpretation of contaminant distributions. Numerical modeling of sitewide ground-water flow also supported the overall project goals. Water-level monitoring was performed to evaluate ground-water flow directions, to track changes in water levels, and to relate such changes to changes in site disposal practices. Water levels over most of the Hanford Site continued to decline between June 1993 and June 1994. These declines are part of the continued response to the cessation of discharge to U Pond and other disposal facilities. The low permeability in this area which enhanced mounding of waste-water discharge has also slowed the response to the reduction of disposal.

Dresel, P.E.; Thorne, P.D.; Luttrell, S.P. [and others

1995-08-01T23:59:59.000Z

142

Pantex breaks ground on renewable energy project | National Nuclear  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

breaks ground on renewable energy project | National Nuclear breaks ground on renewable energy project | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex breaks ground on renewable energy project Pantex breaks ground on renewable energy project Posted By Office of Public Affairs Today was a rare windless day on the plains of the Texas Panhandle, but

143

Pantex breaks ground on renewable energy project | National Nuclear  

National Nuclear Security Administration (NNSA)

breaks ground on renewable energy project | National Nuclear breaks ground on renewable energy project | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex breaks ground on renewable energy project Pantex breaks ground on renewable energy project Posted By Office of Public Affairs Today was a rare windless day on the plains of the Texas Panhandle, but

144

DOE Under Secretary Kristina Johnson Visits INL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DOE Under Secretary Kristina Johnson Visits INL Idaho National Laboratory Nuclear Science and Technology Operations Manager Mike Goff discusses operations at the INL Hot Fuel...

145

Pacific Northwest National Laboratory Grounds Maintenance  

Broader source: Energy.gov (indexed) [DOE]

Pacific Pacific Northwest National Laboratory (PNNL) operates an award-winning grounds maintenance program that comprises a comprehensive landscape and irrigation management program. The program has helped the laboratory reduce its water use for irrigation by 30%. PNNL is located in Richland, Washington, and is managed and operated by Battelle for the U.S. Department of Energy (DOE). PNNL scientists and engineers perform research on a variety of subjects, including energy and national security. PNNL has more than 4,200 staff members, sits on 600 acres, and houses 2 million square feet of facilities. The laboratory is located in an arid region of the state, receiving only eight inches of precipitation annually. It has more than 100 acres of turf and landscaped areas and

146

NLS ground states on graphs  

E-Print Network [OSTI]

We investigate the existence of ground states for the subcritical NLS energy on metric graphs. In particular, we find out a topological assumption that guarantees the nonexistence of ground states, and give an example in which the assumption is not fulfilled and ground states actually exist. In order to obtain the result, we introduce a new rearrangement technique, adapted to the graph where it applies. Owing to such a technique, the energy level of the rearranged function is improved by conveniently mixing the symmetric and monotone rearrangement procedures.

Riccardo Adami; Enrico Serra; Paolo Tilli

2014-06-16T23:59:59.000Z

147

Calibrating Pesticide Application Ground Equipment  

E-Print Network [OSTI]

This pocket-sized guide gives step-by-step instructions for calibrating ground sprayers. Tables provide instructions, examples and sample formulas for determining speed of application, flow rate and the amount of pesticide to add to the tank....

Shaw, Bryan W.

2000-07-05T23:59:59.000Z

148

Cleanup Verification Package for the 118-F-6 Burial Ground  

SciTech Connect (OSTI)

This cleanup verification package documents completion of remedial action for the 118-F-6 Burial Ground located in the 100-FR-2 Operable Unit of the 100-F Area on the Hanford Site. The trenches received waste from the 100-F Experimental Animal Farm, including animal manure, animal carcasses, laboratory waste, plastic, cardboard, metal, and concrete debris as well as a railroad tank car.

H. M. Sulloway

2008-10-02T23:59:59.000Z

149

BehaviorGrounded Representation of Tool Affordances Alexander Stoytchev  

E-Print Network [OSTI]

such as welding, cutting, and painting, but these operations are carefully scripted by a human programmer. RobotBehavior­Grounded Representation of Tool Affordances Alexander Stoytchev Mobile Robot Laboratory introduces a novel approach to rep­ resenting and learning tool affordances by a robot. The tool

150

The Ground State Energy of Heavy Atoms: the Leading Correction  

E-Print Network [OSTI]

For heavy atoms (large atomic number $Z$) described by no-pair operators in the Furry picture we find the ground state's leading energy correction. We compare the result with (semi-)empirical values and Schwinger's prediction showing more than qualitative agreement.

Michael Handrek; Heinz Siedentop

2014-11-21T23:59:59.000Z

151

Marketing Ground Source Heat Pump Advanced Applications that  

E-Print Network [OSTI]

Solar Thermal n Real World Examples Overview #12;n High First Cost n Incompetent Contractor n Operating Wallace President, Energy Environmental Corporation October 9, 2013 #12;Within the United States, what is the fastest growing market with the available capital and need for the benefits of ground source heat pumps

152

EA-1203: Trench 33 Widening in 218-W-5 Low-level Burial Ground, Hanford  

Broader source: Energy.gov (indexed) [DOE]

3: Trench 33 Widening in 218-W-5 Low-level Burial Ground, 3: Trench 33 Widening in 218-W-5 Low-level Burial Ground, Hanford Site, Richland, Washington EA-1203: Trench 33 Widening in 218-W-5 Low-level Burial Ground, Hanford Site, Richland, Washington SUMMARY This EA evaluates the environmental impacts for the proposal to widen and operate the unused Trench 33 in the 218-W-5 Low-Level Burial Ground at the U.S. Department of Energy's Richland Operations Office. PUBLIC COMMENT OPPORTUNITIES None available at this time. DOCUMENTS AVAILABLE FOR DOWNLOAD July 28, 1997 EA-1203: Finding of No Significant Impact Trench 33 Widening in 218-W-5 Low-level Burial Ground, Hanford Site, Richland, Washington July 28, 1997 EA-1203: Final Environmental Assessment Trench 33 Widening in 218-W-5 Low-level Burial Ground, Hanford Site, Richland, Washington

153

Questa Baseline and Pre-Mining Ground-Water Quality Investigation. 3. Historical Ground-Water  

E-Print Network [OSTI]

............................................................................................................................................................... 9 Mine history and ground-water development ....................................................................................................................................................... 11 Ground-water quality database.......................................................................................................................................................... 29 Compilation of complete database

154

Analysis of accidents during flashing operations  

E-Print Network [OSTI]

occurred at intersections under flashing operation compared to those operating in the normal mode. A statistical analysis was conducted to determine the safety of flashing signal operation. No significant increases in accidents or accident severity were...

Obermeyer, Michael Edward

2012-06-07T23:59:59.000Z

155

192 ASHRAE Transactions: Research Ground-source heat pumps for cooling-dominated  

E-Print Network [OSTI]

192 ASHRAE Transactions: Research ABSTRACT Ground-source heat pumps for cooling- tion of the heat pump performance is avoided by offsetting the annual load imbalance in the borefield operating and control strategies in a hybrid ground-source heat pump application using an hourly system

Ghajar, Afshin J.

156

Cleanup Verification Package for the 118-C-1, 105-C Solid Waste Burial Ground  

SciTech Connect (OSTI)

This cleanup verification package documents completion of remedial action for the 118-C-1, 105-C Solid Waste Burial Ground. This waste site was the primary burial ground for general wastes from the operation of the 105-C Reactor and received process tubes, aluminum fuel spacers, control rods, reactor hardware, spent nuclear fuel and soft wastes.

M. J. Appel and J. M. Capron

2007-07-25T23:59:59.000Z

157

On Some Movements of the Ground in Geneva  

Science Journals Connector (OSTI)

......construction and alignment of the 25 GeV proton synchroton at CERN. On Some Movements of the Ground...and align- ment of the 25 GeV proton synchroton at CERN. The 25000 million electron volt synchroton (the Eurotron) that has been under construction......

A. Decae

1960-03-01T23:59:59.000Z

158

Ground Magnetics | Open Energy Information  

Open Energy Info (EERE)

Ground Magnetics Ground Magnetics Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Ground Magnetics Details Activities (15) Areas (12) Regions (0) NEPA(1) Exploration Technique Information Exploration Group: Geophysical Techniques Exploration Sub Group: Magnetic Techniques Parent Exploration Technique: Magnetic Techniques Information Provided by Technique Lithology: Presence of magnetic minerals such as magnetite. Stratigraphic/Structural: Mapping of basement structures, horst blocks, fault systems, fracture zones, dykes and intrusions. Hydrological: The circulation of hydrothermal fluid may impact the magnetic susceptibility of rocks. Thermal: Rocks lose their magnetic properties at the Curie temperature (580° C for magnetite) [1] and, upon cooling, remagnetize in the present magnetic field orientation. The Curie point depth in the subsurface may be determined in a magnetic survey to provide information about hydrothermal activity in a region.

159

Operating Guidelines Narrative.DOC  

Broader source: Energy.gov (indexed) [DOE]

Competitive Sourcing Program Operating Guidelines Issued under authority of: Competitive Sourcing Executive Steering Group July 1, 2004 DOE Competitive Sourcing Program OPERATING GUIDELINES (CS-OG-01) i COMPETITIVE SOURCING PROGRAM OPERATING GUIDELINES Table of Contents 1. REFERENCES ................................................................................................................................... 1 2. PURPOSE ........................................................................................................................................... 1 3. APPLICABILITY AND SCOPE ......................................................................................................

160

Operating Guidelines Narrative.DOC  

Broader source: Energy.gov (indexed) [DOE]

Competitive Sourcing Program Operating Guidelines Issued under authority of: Competitive Sourcing Executive Steering Group July 1, 2004 DOE Competitive Sourcing Program OPERATING GUIDELINES (CS-OG-01) i COMPETITIVE SOURCING PROGRAM OPERATING GUIDELINES Table of Contents 1. REFERENCES ................................................................................................................................... 1 2. PURPOSE ........................................................................................................................................... 1 3. APPLICABILITY AND SCOPE ......................................................................................................

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

OPERATIONS (OPS)  

Broader source: Energy.gov (indexed) [DOE]

OPS) OPS) OBJECTIVE OPS.1 The formality and discipline of operations is adequate to conduct work safely and programs are in place to maintain this formality and discipline. (CR 13) Scope: The Conduct of Operations Program was evaluated during the recent KE Basin FTS ORR and was found to be adequately implemented. Based on this result and the subsequent program enhancements, the scope of the review is to be limited to the SWS operating and maintenance evolutions. Criteria * Programmatic elements of conduct of operations are in place for SWS operations. (DOE Order 5480.19) * The SWS operations personnel adequately demonstrate the principles of conduct of operations requirements during the shift performance period. (DOE Order 5480.19)

162

Broadband Ground-Plane Cloak  

Science Journals Connector (OSTI)

...automated design process. The ground-plane...Maxwell's equations implies that...number of simulations of the metamaterial...cloak-design process and makes...Jacobian matrix {lambda...Jacobian matrix). In our...retrieval process, modified...numerical simulation. A regression...a single Matlab program...Adobe Acrobat PDF format...

R. Liu; C. Ji; J. J. Mock; J. Y. Chin; T. J. Cui; D. R. Smith

2009-01-16T23:59:59.000Z

163

Cooking with Ground Pork (Spanish)  

E-Print Network [OSTI]

? 10 minutos, o hasta que las tiras de tortilla est?n suaves. S?rvalo caliente. Adaptado de Commodity Fact Sheet for USDA Household Programs: Frozen Ground Pork (folleto de informaci?n sobre productos preparado para los Programas del Hogar del...

Anding, Jenna

2008-12-09T23:59:59.000Z

164

SPEAR Operations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Interface 1113 N. Kurita J. Langton Vacuum TSP's 1120 J. Corbett A. Terebilo MATLAB Applications - Basics 1121 F. Rafael Booster Kicker Upgrade, Operation Manual 1121...

165

operations center  

National Nuclear Security Administration (NNSA)

1%2A en Operations Center http:nnsa.energy.govaboutusourprogramsemergencyoperationscounterterrorismoperationscenter

...

166

Efficient, Portable, and Robust Extension of Operating System Functionality  

E-Print Network [OSTI]

Efficient, Portable, and Robust Extension of Operating System Functionality Amin Vahdat, Douglas, operating systems are not chosen for underlying system features, but rather for the performance of the underlying hardware, available application programs, and system stability. Consequently, operating system

Newhall, Tia

167

Energy Department Training Breaks New Ground | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Training Breaks New Ground Training Breaks New Ground Energy Department Training Breaks New Ground December 3, 2013 - 1:00pm Addthis The Federal Energy Management Program is now an authorized provider of continuing education units from the International Association for Continuing Education and Training. Watch the video above to learn more. Timothy Unruh FEMP Program Manager High quality education for federal government employees helps streamline operations, improve services, and ensure that taxpayer dollars are spent wisely. This is why I am pleased to announce the Energy Department's Federal Energy Management Program (FEMP) has earned the designation as an "Authorized Provider" of continuing education units (CEUs) by the prestigious International Association for Continuing Education and Training

168

Optimal Design of Grounding System for HV / EHV Substations in Two Layered Soil  

E-Print Network [OSTI]

Abstract — Successful operation of entire power system depends to a considerable extent on efficient and satisfactory performance of substations. Hence substations in general can be considered as heart of overall power system. In any substation, a well designed grounding plays an important role. Since absence of safe and effective grounding system can result in mal-operation or non-operation of control and protective devices, grounding system design deserves considerable attention for all the substations. Grounding system has to be safe as it is directly concerned with safety of persons working within the substation. Main purpose of this work is designing safe and cost effective grounding systems for HV / EHV substations situated at such locations where soil of the substation site is not uniform. Here soil is considered to be horizontally stratified into two layers. Initially significance of two layered soil model is introduced and design methodology for design of substation grounding system is discussed. Next, two design problems have been solved by using newly developed software and results obtained here are verified with the help of Ground Grid Systems module of ETAP – professional software. Comparison of the results obtained by both the software shows nice agreement of the results given by ESGSD with those obtained from ETAP. Hence this software is found to be quite satisfactory tool in the field of design of grounding system for HV / EHV substations.

unknown authors

169

CONSTRUCTION OF KEY CLEANUP PROJECT GAINS GOOD GROUND AT SRS | Department  

Broader source: Energy.gov (indexed) [DOE]

CONSTRUCTION OF KEY CLEANUP PROJECT GAINS GOOD GROUND AT SRS CONSTRUCTION OF KEY CLEANUP PROJECT GAINS GOOD GROUND AT SRS CONSTRUCTION OF KEY CLEANUP PROJECT GAINS GOOD GROUND AT SRS June 1, 2010 - 12:00pm Addthis CONSTRUCTION OF KEY CLEANUP PROJECT GAINS GOOD GROUND AT SRS Aiken, SC - Construction of a key cleanup facility at the Savannah River Site (SRS) is gaining some serious ground given the remarkable building progress since Fall 2009. Construction and operation of the Salt Waste Processing Facility (SWPF) is among the U.S. Department of Energy's (DOE) highest cleanup priorities. When operational, SWPF will treat millions of gallons of salt waste currently stored in 49 underground tanks at SRS by removing radioactive constituents for vitrification at the nearby Defense Waste Processing Facility. Disposition of the salt waste inventory is a

170

CONSTRUCTION OF KEY CLEANUP PROJECT GAINS GOOD GROUND AT SRS | Department  

Broader source: Energy.gov (indexed) [DOE]

CONSTRUCTION OF KEY CLEANUP PROJECT GAINS GOOD GROUND AT SRS CONSTRUCTION OF KEY CLEANUP PROJECT GAINS GOOD GROUND AT SRS CONSTRUCTION OF KEY CLEANUP PROJECT GAINS GOOD GROUND AT SRS June 1, 2010 - 12:00pm Addthis CONSTRUCTION OF KEY CLEANUP PROJECT GAINS GOOD GROUND AT SRS Aiken, SC - Construction of a key cleanup facility at the Savannah River Site (SRS) is gaining some serious ground given the remarkable building progress since Fall 2009. Construction and operation of the Salt Waste Processing Facility (SWPF) is among the U.S. Department of Energy's (DOE) highest cleanup priorities. When operational, SWPF will treat millions of gallons of salt waste currently stored in 49 underground tanks at SRS by removing radioactive constituents for vitrification at the nearby Defense Waste Processing Facility. Disposition of the salt waste inventory is a

171

Hanford Site ground-water monitoring for 1993  

SciTech Connect (OSTI)

This report presents the results of the Ground-Water Surveillance Project monitoring for calendar year 1993 on the Hanford Site, Washington. Hanford Site operations from 1943 onward produced large quantities of radiological and chemical waste that have impacted ground-water quality on the Site. Monitoring of water levels and ground-water chemistry is performed to track the extent of contamination and trends in contaminant concentrations. The 1993 monitoring was also designed to identify emerging ground-water quality problems. The information obtained is used to verify compliance with applicable environmental regulations and to evaluate remedial actions. Data from other monitoring and characterization programs were incorporated to provide an integrated assessment of Site ground-water quality. Additional characterization of the Site`s geologic setting and hydrology was performed to support the interpretation of contaminant distributions. Numerical modeling of sitewide ground-water flow also supported the overall project goals. Water-level monitoring was performed to evaluate ground-water flow directions, to track changes in water levels, and to relate such changes to changes in site disposal practices. Water levels over most of the Hanford Site continued to decline between June 1992 and June 1993. The greatest declines occurred in the 200-West Area. These declines are part of the continued response to the cessation of discharge to U Pond and other disposal facilities. The low permeability in this area which enhanced mounding of waste-water discharge has also slowed the response to the reduction of disposal. Water levels remained nearly constant in the vicinity of B Pond, as a result of continued disposal to the pond. Water levels measured from wells in the unconfined aquifer north and east of the Columbia River indicate that the primary source of recharge is irrigation practices.

Dresel, P.E.; Luttrell, S.P.; Evans, J.C. [and others

1994-09-01T23:59:59.000Z

172

Ground Motion Studies at NuMI  

SciTech Connect (OSTI)

Ground motion can cause significant deterioration in the luminosity of a linear collider. Vibration of numerous focusing magnets causes continuous misalignments, which makes the beam emittance grow. For this reason, understanding the seismic vibration of all potential LC sites is essential and related efforts in many sites are ongoing. In this document we summarize the results from the studies specific to Fermilab grounds as requested by the LC project leader at FNAL, Shekhar Mishra in FY04-FY06. The Northwestern group focused on how the ground motion effects vary with depth. Knowledge of depth dependence of the seismic activity is needed in order to decide how deep the LC tunnel should be at sites like Fermilab. The measurements were made in the NuMI tunnel, see Figure 1. We take advantage of the fact that from the beginning to the end of the tunnel there is a height difference of about 350 ft and that there are about five different types of dolomite layers. The support received allowed to pay for three months of salary of Michal Szleper. During this period he worked a 100% of his time in this project. That include one week of preparation: 2.5 months of data taking and data analysis during the full period of the project in order to guarantee that we were recording high quality data. We extended our previous work and made more systematic measurements, which included detailed studies on stability of the vibration amplitudes at different depths over long periods of time. As a consequence, a better control and more efficient averaging out of the daytime variation effects were possible, and a better study of other time dependences before the actual depth dependence was obtained. Those initial measurements were made at the surface and are summarized in Figure 2. All measurements are made with equipment that we already had (two broadband seismometers KS200 from GEOTECH and DL-24 portable data recorder). The offline data analysis took advantage of the full Fourier spectra information and the noise was properly subtracted. The basic formalism is summarized if Figure 3. The second objective was to make a measurement deeper under ground (Target hall, Absorber hall and Minos hall - 150 ft to 350 ft), which previous studies did not cover. All results are summarized in Figure 3 and 4. The measurements were covering a frequency range between 0.1 to 50 Hz. The data was taken continuously for at least a period of two weeks in each of the locations. We concluded that the dependence on depth is weak, if any, for frequencies above 1 Hz and not visible at all at lower frequencies. Most of the attenuation (factor of about 2-3) and damping of ground motion that is due to cultural activity at the surface is not detectable once we are below 150 ft underground. Therefore, accelerator currently under consideration can be build at the depth and there is no need to go deeper underground is built at Fermi National Laboratory.

Mayda M. Velasco; Michal Szleper

2012-02-20T23:59:59.000Z

173

Ground Magnetics (Nannini, 1986) | Open Energy Information  

Open Energy Info (EERE)

Ground Magnetics (Nannini, 1986) Ground Magnetics (Nannini, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Magnetics (Nannini, 1986) Exploration Activity Details Location Unspecified Exploration Technique Ground Magnetics Activity Date Usefulness not indicated DOE-funding Unknown Notes Detection and quantitative assessment of such intrusive events can be facilitated by magnetic surveys (ground or aerial magnetic field measurements). These surveys are based on the magnetic susceptibility contrast between magmatic rocks at depth and the sedimentary formations above. References Raffaello Nannini (1986) Some Aspects Of Exploration In Non-Volcanic Areas Retrieved from "http://en.openei.org/w/index.php?title=Ground_Magnetics_(Nannini,_1986)&oldid=388291

174

Equipment Operational Requirements  

SciTech Connect (OSTI)

The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

2009-06-11T23:59:59.000Z

175

Variable pressure operation: An assessment  

SciTech Connect (OSTI)

This report summarizes the benefits, drawbacks, and technical issues of variable pressure operation (VPO) retrofit. Under VPO, turbine throttle pressure is reduced at low loads. This operating mode offers several significant advantages for units that cycle or operate at low loads for extended periods. Information used in the report was assembled from published sources, from major equipment manufacturers, and from utilities operating units under VPO in the US, Europe and Japan. The report also contains statistics of VPO use in this country and abroad. Design features of new units using VPO in Europe and Japan are presented to identify potential directions for future US designs incorporating VPO.

Kimel, E.; Kemeny, P.; Bierman, E.; Lagomarsino, J.; Clarke, D. (Burns and Roe, Inc., Oradell, NJ (USA))

1990-03-01T23:59:59.000Z

176

Design operators  

E-Print Network [OSTI]

Design operators is a thesis that investigates the nature and characteristics of the design process by examining the interaction of computation with architectural design. The effects of the introduction of these media in ...

Dritsas, Stylianos, 1978-

2004-01-01T23:59:59.000Z

177

Business Operations  

Office of Energy Efficiency and Renewable Energy (EERE)

The Office of Business Operations is the central organization for all Office of Energy Efficiency and Renewable Energy (EERE) business products, processes, and systems. The three main offices of...

178

Operating Costs  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This chapter is focused on capital costs for conventional construction and environmental restoration and waste management projects and examines operating cost estimates to verify that all elements of the project have been considered and properly estimated.

1997-03-28T23:59:59.000Z

179

Ground-water characterization field activities for 1995--1996 Laboratory for Energy-Related Health Research, University of California, Davis  

SciTech Connect (OSTI)

This report documents ground-water characterization field activities completed from August to December 1995 and in January 1996 at the Laboratory for Energy-Related Health Research (LEHR) in Davis, California. The ground water at LEHR is one of several operable units under investigation by Pacific Northwest National Laboratory for the US Department of Energy. The purpose of this work was to further characterize the hydrogeology beneath the LEHR site, with the primary focus on ground water. The objectives were to estimate hydraulic properties for the two uppermost saturated hydrogeologic units (i.e., HSU-1 and HSU-2), and to determine distributions of contaminants of concern in these units. Activities undertaken to accomplish these objectives include well installation, geophysical logging, well development, ground-water sampling, slug testing, Westbay ground-water monitoring system installation, continuous water-level monitoring, Hydropunch installation, and surveying. Ground-water samples were collected from 61 Hydropunch locations. Analytical results from these locations and the wells indicate high chloroform concentrations trending from west/southwest to east/northeast in the lower portion of HSU-1 and in the upper and middle portions of HSU-2. The chloroform appears to originate near Landfill 2. Tritium was not found above the MCL in any of the well or Hydropunch samples. Hexavalent chromium was found at four locations with concentrations above the MCL in HSU-1 and at one location in HSU-2. One well in HSU-1 had a total chromium concentration above the MCL. Nitrate-nitrogen above the MCL was found at several Hydropunch locations in both HSU-1 and HSU-2.

Liikala, T.L.; Lanigan, D.C.; Last, G.V. [and others

1996-05-01T23:59:59.000Z

180

A Ground Systems Template for Remote Sensing Systems  

Science Journals Connector (OSTI)

Spaceborne remote sensing using gamma and X?ray spectrometers requires particular attention to the design and development of reliable systems. These systems must ensure the scientific requirements of the mission within the challenging technical constraints of operating instrumentation in space. The Near Earth Asteroid Rendezvous (NEAR) spacecraft included X?ray and gamma?ray spectrometers (XGRS) whose mission was to map the elemental chemistry of the 433 Eros asteroid. A remote sensing system template similar to a blackboard systems approach used in artificial intelligence was identified in which the spacecraft instrument and ground system was designed and developed to monitor and adapt to evolving mission requirements in a complicated operational setting. Systems were developed for ground tracking of instrument calibration instrument health data quality orbital geometry solar flux as well as models of the asteroid’s surface characteristics requiring an intensive human effort. In the future missions such as the Autonomous Nano?Technology Swarm (ANTS) program will have to rely heavily on automation to collectively encounter and sample asteroids in the outer asteroid belt. Using similar instrumentation ANTS will require information similar to data collected by the NEAR X?ray/Gamma?Ray Spectrometer (XGRS) ground system for science and operations management. The NEAR XGRS systems will be studied to identify the equivalent subsystems that may be automated for ANTS. The effort will also investigate the possibility of applying blackboard style approaches to automated decision making required for ANTS.

Timothy P. McClanahan; Jacob I. Trombka; Samuel R. Floyd; Walter Truskowski; Richard D. Starr; Pamela E. Clark; Larry G. Evans

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Worldwide Occurrences of Arsenic in Ground Water  

Science Journals Connector (OSTI)

...decision-making process of water managers, remediation specialists, and...The geologic and ground-water conditions that promote...water managers, remediation specialists, and...The geologic and ground-water conditions that promote...

D. Kirk Nordstrom

2002-06-21T23:59:59.000Z

182

Montana Ground Water Assessment Act (Montana)  

Broader source: Energy.gov [DOE]

This statute establishes a program to systematically assess and monitor the state's ground water and to disseminate the information to interested persons in order to improve the quality of ground...

183

Warm or Steaming Ground | Open Energy Information  

Open Energy Info (EERE)

Warm or Steaming Ground Warm or Steaming Ground Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Warm or Steaming Ground Dictionary.png Warm or Steaming Ground: An area where geothermal heat is conducted to the earth's surface, warming the ground and sometimes causing steam to form when water is present. Other definitions:Wikipedia Reegle Modern Geothermal Features Typical list of modern geothermal features Hot Springs Fumaroles Warm or Steaming Ground Mudpots, Mud Pools, or Mud Volcanoes Geysers Blind Geothermal System Steam rising from the ground at Eldvorp, a 10 km row of craters, in Southwestern Iceland. http://www.visiticeland.com/SearchResults/Attraction/eldvorp Warm or steaming ground is often an indicator of a geothermal system beneath the surface. In some cases a geothermal system may not show any

184

Ground Source Heat Pump Demonstration Projects  

Broader source: Energy.gov [DOE]

Below are the project presentations and respective peer review results for Ground Source Heat Pump Demonstration Projects.

185

Ground Source Heat Pump Subprogram Overview  

Broader source: Energy.gov [DOE]

This overview of GTP's Ground Source Heat Pump subprogram was given at GTP's Program Peer Review on May 18, 2010.

186

North Village Ground Source Heat Pumps  

Broader source: Energy.gov [DOE]

Overview: Installation of Ground Source Heat Pumps. Replacement of Aging Heat Pumps. Alignment with Furmans Sustainability Goals.

187

Stability of ice-sheet grounding lines  

Science Journals Connector (OSTI)

...81 73 Stability of ice-sheet grounding lines Richard F. Katz 1 * M. Grae Worster 2...ice sheets are sensitive to grounding-line position and variation, characteristics...models. We present a theory for grounding-line dynamics in three spatial dimensions and...

2010-01-01T23:59:59.000Z

188

Situational Awareness of a Ground Robot from an Unmanned Aerial Vehicle  

E-Print Network [OSTI]

possible without the support of the Defense Threat Reduction Agency and the partnership of Savannah River an Unmanned Aerial Vehicle Daniel Hager ABSTRACT In the operation of unmanned vehicles, safety is a primary system that allows for safe deployment and operation of a ground robot from an unmanned aerial vehicle

Kochersberger, Kevin

189

BOREAS Operations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Study Area Operations/Thompson Airport (NSA-Ops) Study Area Operations/Thompson Airport (NSA-Ops) NSA Operations (NSA-Ops) The Keewatin Air Hanger: site of BOREAS Ops 1994 Dr. Piers Sellers working in Ops, 1994 BOREAS "Air Force" The NASA C-130 The University of Wyoming King Air The NASA Helicopter The NRC Twin Otter The NCAR Electra The Ontario Chieftain Back to the BOREAS Photo Page Index Other Sites: NSA Photos ||NSA-BP Photos | NSA-Fen Photos | NSA-OA Photos | NSA-OBS Photos | NSA-OJP Photos | NSA-UBS Photos | NSA-YJP Photos | NSA-Ops Photos SSA Photos || SSA-Airport Photos | SSA-Fen Photos | SSA-Mix Photos | SSA-OA Photos | SSA-OBS Photos | SSA-OJP Photos | SSA-YA Photos | SSA-YJP Photos | SSA-Ops Photos | ORNL DAAC Home || ORNL Home || NASA || Privacy, Security, Notices || Data Citation || Rate Us || Help |

190

SSA Operations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Area Operations (SSA-Ops) Area Operations (SSA-Ops) "BOREAS Ops" was located at the Snodrifters Lodge, in Candle Lake, Saskatchewan. Radiosonde balloon launch at Ops The NASA Helicopter lands at Ops A meeting at the Snodrifter's Lodge Release of a radiosonde at the SSA operations center in Candle Lake. Back to the BOREAS Photo Page Index Other Sites: NSA Photos ||NSA-BP Photos | NSA-Fen Photos | NSA-OA Photos | NSA-OBS Photos | NSA-OJP Photos | NSA-UBS Photos | NSA-YJP Photos | NSA-Ops Photos SSA Photos || SSA-Airport Photos | SSA-Fen Photos | SSA-Mix Photos | SSA-OA Photos | SSA-OBS Photos | SSA-OJP Photos | SSA-YA Photos | SSA-YJP Photos | SSA-Ops Photos | ORNL DAAC Home || ORNL Home || NASA || Privacy, Security, Notices || Data Citation || Rate Us || Help | User Services - Tel: +1 (865) 241-3952 or E-mail: uso@daac.ornl.gov

191

Interim site characterization report and ground-water monitoring program for the Hanford site solid waste landfill  

SciTech Connect (OSTI)

Federal and state regulations governing the operation of landfills require utilization of ground-water monitoring systems to determine whether or not landfill operations impact ground water at the point of compliance (ground water beneath the perimeter of the facility). A detection-level ground-water monitoring system was designed, installed, and initiated at the Hanford Site Solid Waste Landfill (SWL). Chlorinated hydrocarbons were detected at the beginning of the ground-water monitoring program and continue to be detected more than 1 year later. The most probable source of the chlorinated hydrocarbons is washwater discharged to the SWL between 1985 and 1987. This is an interim report and includes data from the characterization work that was performed during well installation in 1987, such as field observations, sediment studies, and geophysical logging results, and data from analyses of ground-water samples collected in 1987 and 1988, such as field parameter measurements and chemical analyses. 38 refs., 27 figs., 8 tabs.

Fruland, R.M.; Hagan, R.A.; Cline, C.S.; Bates, D.J.; Evans, J.C.; Aaberg, R.L.

1989-07-01T23:59:59.000Z

192

Connecting the second exhaust-heat boiler to the operating first one under the conditions of flow circuits of combined-cycle plants with two gas-turbine units and one steam turbine  

Science Journals Connector (OSTI)

Problems arising with connecting the second exhaust-heat boiler to the first exhaust-heat boiler under load in the case of flow circuits of combined-cycle plants of type PGU-450 are considered. Similar problem...

Yu. A. Radin; I. A. Grishin; T. S. Kontorovich…

2006-03-01T23:59:59.000Z

193

Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.  

E-Print Network [OSTI]

, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL) University of New Mexico, Albuquerque, NM, USA 13) General Atomics, San Diego, CA, USA 14) Mission Research

194

Atlas SCT/Pixel Grounding and Shielding ATLAS SCT/Pixel Grounding and Shielding Note  

E-Print Network [OSTI]

Atlas SCT/Pixel Grounding and Shielding 1 ATLAS SCT/Pixel Grounding and Shielding Note November 22 mostly connects existing mechanical electrical conductive #12; Atlas SCT/Pixel Grounding and Shielding 2 that equivalent. The barrel outer heat shield (150 aluminum) main element shield. #12; Atlas SCT/Pixel Grounding

California at Santa Cruz, University of

195

Substation Operation  

Science Journals Connector (OSTI)

... THIS book is intended to help the workman to understand the principles of substation operation. It is a good attempt at giving somewhat advanced technical knowledge in such ... ." We are told not to use water to put out a fire at a substation before the station has been made completely " dead." The reason given for this ...

1925-08-01T23:59:59.000Z

196

EA-1276: Widening Trench 36 of the 218-E-12B Low-level Burial Ground,  

Broader source: Energy.gov (indexed) [DOE]

76: Widening Trench 36 of the 218-E-12B Low-level Burial 76: Widening Trench 36 of the 218-E-12B Low-level Burial Ground, Hanford Site, Richland, Washington EA-1276: Widening Trench 36 of the 218-E-12B Low-level Burial Ground, Hanford Site, Richland, Washington SUMMARY This EA evaluates the environmental impacts for the proposal to widen and operate unused Trench 36 in the 218-E-12B Low-Level Burial Ground for disposal of low-level waste at the U.S. Department of Energy Hanford Site. PUBLIC COMMENT OPPORTUNITIES None available at this time. DOCUMENTS AVAILABLE FOR DOWNLOAD February 11, 1999 EA-1276: Finding of No Significant Impact Widening Trench 36 of the 218-E-12B Low-level Burial Ground, Hanford Site, Richland, Washington February 11, 1999 EA-1276: Final Environmental Assessment Widening Trench 36 of the 218-E-12B Low-level Burial Ground, Hanford Site,

197

Ground Water Surveillance Monitoring Implementation Guide for Use with DOE O 450.1, Environmental Protection Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Guide assists DOE sites in establishing and maintaining surveillance monitoring programs to detect future impacts on ground water resources from site operations, to track existing ground water contamination, and to assess the potential for exposing the general public to site releases. Canceled by DOE N 251.82.

2004-06-24T23:59:59.000Z

198

Ground motion modeling of Hayward fault scenario earthquakes II:Simulation of long-period and broadband ground motions  

SciTech Connect (OSTI)

We simulate long-period (T > 1.0-2.0 s) and broadband (T > 0.1 s) ground motions for 39 scenarios earthquakes (Mw 6.7-7.2) involving the Hayward, Calaveras, and Rodgers Creek faults. For rupture on the Hayward fault we consider the effects of creep on coseismic slip using two different approaches, both of which reduce the ground motions compared with neglecting the influence of creep. Nevertheless, the scenario earthquakes generate strong shaking throughout the San Francisco Bay area with about 50% of the urban area experiencing MMI VII or greater for the magnitude 7.0 scenario events. Long-period simulations of the 2007 Mw 4.18 Oakland and 2007 Mw 4.5 Alum Rock earthquakes show that the USGS Bay Area Velocity Model version 08.3.0 permits simulation of the amplitude and duration of shaking throughout the San Francisco Bay area, with the greatest accuracy in the Santa Clara Valley (San Jose area). The ground motions exhibit a strong sensitivity to the rupture length (or magnitude), hypocenter (or rupture directivity), and slip distribution. The ground motions display a much weaker sensitivity to the rise time and rupture speed. Peak velocities, peak accelerations, and spectral accelerations from the synthetic broadband ground motions are, on average, slightly higher than the Next Generation Attenuation (NGA) ground-motion prediction equations. We attribute at least some of this difference to the relatively narrow width of the Hayward fault ruptures. The simulations suggest that the Spudich and Chiou (2008) directivity corrections to the NGA relations could be improved by including a dependence on the rupture speed and increasing the areal extent of rupture directivity with period. The simulations also indicate that the NGA relations may under-predict amplification in shallow sedimentary basins.

Aagaard, B T; Graves, R W; Rodgers, A; Brocher, T M; Simpson, R W; Dreger, D; Petersson, N A; Larsen, S C; Ma, S; Jachens, R C

2009-11-04T23:59:59.000Z

199

Operation Poorman  

SciTech Connect (OSTI)

The objectives of Operation Poorman were to design and build a portable seismic system and to set up and use this system in a cold-weather environment. The equipment design uses current technology to achieve a low-power, lightweight system that is configured into three modules. The system was deployed in Alaska during wintertime, and the results provide a basis for specifying a mission-ready seismic verification system.

Pruvost, N.; Tsitouras, J.

1981-03-18T23:59:59.000Z

200

Surfactants for ground water remediation  

Science Journals Connector (OSTI)

Ground water contamination is a most intractable form of pollution. Spilled solvent or fuel liquids are trapped below the water table by colloidal forces. Surfactants may be used to dramatically improve contaminated aquifer remediation rates. Principal remediation mechanisms include micellar solubilization and mobilization of the trapped liquids by lowering of the oil/water interfacial tension. Surfactant selection is a key to the successful design of a remediation effort, and involves consideration of factors including Krafft Point, surfactant adsorption onto the aquifer solids, and the phase behavior of the oil/water/surfactant system. Successful field demonstrations have occurred in recent months and the technology is moving rapidly toward commercialization. Critical research issues remain including acceptable clean-up levels, surfactant/contaminant in situ biodegradation rates, and surfactant decontamination and reuse.

Jeffrey H. Harwell; David A. Sabatini; R.C. Knox

1999-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Ground movements associated with gas hydrate production. Final report  

SciTech Connect (OSTI)

This report deals with a study directed towards a modeling effort on production related ground movements and subsidence resulting from hydrate dissociation. The goal of this research study was to evaluate whether there could be subsidence related problems that could be an impediment to hydrate production. During the production of gas from a hydrate reservoir, it is expected that porous reservoir matrix becomes more compressible which may cause reservoir compression (compaction) under the influence of overburden weight. The overburden deformations can propagate its influence upwards causing subsidence near the surface where production equipment will be located. In the present study, the reservoir compaction is modeled by using the conventional ``stress equilibrium`` approach. In this approach, the overburden strata move under the influence of body force (i.e. self weight) in response to the ``cavity`` generated by reservoir depletion. The present study is expected to provide a ``lower bound`` solution to the subsidence caused by hydrate reservoir depletion. The reservoir compaction anticipated during hydrate production was modeled by using the finite element method, which is a powerful computer modeling technique. The ground movements at the reservoir roof (i.e. reservoir compression) cause additional stresses and disturbance in the overburden strata. In this study, the reservoir compaction was modeled by using the conventional ``stress equilibrium`` approach. In this approach, the overburden strata move under the influence of body force (i.e. self weight) in response to the ``cavity`` generated by reservoir depletion. The resulting stresses and ground movements were computed by using the finite element method. Based on the parameters used in this investigation, the maximum ground subsidence could vary anywhere from 0.50 to 6.50 inches depending on the overburden depth and the size of the depleted hydrate reservoir.

Siriwardane, H.J.; Kutuk, B.

1992-03-01T23:59:59.000Z

202

AUTHORIZATION TO CONTINUE OPERATION OF  

Broader source: Energy.gov (indexed) [DOE]

Contract Competition] Contract Competition] AUTHORIZATION TO CONTINUE OPERATION OF THE_[insert the name of the laboratory/site/facility]___ UNDER A MANAGEMENT AND OPERATING CONTRACT The _[insert the name of the laboratory/site/facility]_ is currently managed and operated by _[insert the name of the contractor]_ for the Department of Energy under a Management and Operating (M&O) contract as defined in Federal Acquisition Regulation (FAR) Subpart 17.6. The current contract and the determination authorizing the M&O form of contract expire on _[insert the expiration date]_. _[In one or two sentences, briefly describe the laboratory/site/facility mission]_. A new contract is currently being procured by the DOE _[insert DOE office name]_, under Request for Proposals (RFP) number _[insert RFP number]_. The resultant

203

Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.  

E-Print Network [OSTI]

, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL with high-number wire arrays The conversion of Sandia's Particle Beam Fusion Accelerator II (PBFA II output ~1.6 MJ ~200 TW Marx 11.4 MJ water vacuum Electrical to x-ray energy Conversion efficiency ~ 15

204

TEX-A-SYST: Reducing the Risk of Ground Water Contamination by Improving Livestock Holding Pen Management  

E-Print Network [OSTI]

Open lots or holding pens for feeding or holding livestock can be sources of ground water contamination. The safety of such operations depends on their separation from water wells, characteristics of the site, and proper management. This publication...

Harris, Bill L.; Hoffman, D.; Mazac Jr., F. J.

1997-08-29T23:59:59.000Z

205

P ORNiiTM-7004 Results of Ground Level Radiation  

Office of Legacy Management (LM)

ORNiiTM-7004 ORNiiTM-7004 Results of Ground Level Radiation Measurements in Support of the 1978 Aerial Survey of the Lake Ontario Ordnance W o rks, Lewiston, New York _ ict~~.. By A, grven _, ,_~ ~.~ _,. :::;(' ~. . ' -- .- ,. R. W . Doane F. F. Haywood W . H. Shinpaugh ORNL/TM-7004 Dist. Category UC-41 Contract No. W-7405eng-26 RESULTS OF GROUND LEVEL RADIATION MEASUREMENTS IN SUPPORT OF THE 1978 AERIAL SURVEY OF THE LAKE ONTARIO ORDNANCE WORKS, LEWISTON, NEW YORK B. A. Berven F. F. Haywood R. W. Doane W. H. Shinpaugh Work performed by Health and Safety Research Division Date Published: September 1979 Oak Ridge National Laboratory Oak Ridge, Tennessee 37830 operated by UNION CARBIDE CORPORATION for the DEPARTMENT OF ENERGY as part of the Formerly Utilized Sites -

206

Long-Term Planning for Nuclear Energy Systems Under Deep Uncertainty  

E-Print Network [OSTI]

Uranium is mined from the earth’s crust through a variety of methods – under- ground mining, open-pit mining,

Kim, Lance Kyungwoo

2011-01-01T23:59:59.000Z

207

Testing of a loop heat pipe experimental apparatus under varied acceleration.  

E-Print Network [OSTI]

??An experimental apparatus was designed and fabricated to test a Loop Heat Pipe under varied acceleration. The experiment consisted of both flight and ground testing… (more)

Kurwitz, Richard Cable

2012-01-01T23:59:59.000Z

208

Ground Electromagnetic Techniques | Open Energy Information  

Open Energy Info (EERE)

Ground Electromagnetic Techniques Ground Electromagnetic Techniques (Redirected from Ground Electromagnetic Methods) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Ground Electromagnetic Techniques Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Geophysical Techniques Exploration Sub Group: Electrical Techniques Parent Exploration Technique: Electromagnetic Techniques Information Provided by Technique Lithology: Rock composition, mineral and clay content Stratigraphic/Structural: Detection of permeable pathways, fracture zones, faults Hydrological: Resistivity influenced by porosity, grain size distribution, permeability, fluid saturation, fluid type and phase state of the pore water Thermal: Resistivity influenced by temperature

209

Earth resistivity measurement near substation ground grids  

SciTech Connect (OSTI)

Proper substation grounding grid design requires good, accurate soil resistivity measurements. This data is essential to model the substation ground grid to design a safe ground grid with a satisfactory ground grid resistance at minimum cost. For substations with several decades of service, there is some concern that a grid may have deteriorated, been damaged during equipment installation or excavation, or that initial soil resistivity measurements were lost or may not have been correctly performed. Ground grid conductors change the substation surface voltage distribution. Any voltage measurements taken at the complete substation will also vary from the tests made without conductors present. During testing, current was injected in the soil by probes placed near the ground grid. The current tends to follow the ground grid conductors since copper is a far better conductor than the soil it is placed in. Resistance readings near grids will be lower than readings in undisturbed soil. Since computer models were unavailable for many years, analyzing the effect of the grid conductors on soil resistivity measurements was very difficult. As a result, soil resistivity measurements made close to substations were of little use to the engineer unless some means of correcting the measured values could be developed. This paper will present results of soil resistivity measurements near a substation ground grid before and after a ground grid has been installed and describes a means of calculating the undisturbed soil model.

Lodwig, S.G.; Mateja, S.A. [ComEd, Chicago, IL (United States)

1996-11-01T23:59:59.000Z

210

Design of AC substation grounding system.  

E-Print Network [OSTI]

??The purpose for this paper is to understand the basic foundation used to safely design a substation grounding system for AC systems. The following criteria… (more)

Meas, Ra

2014-01-01T23:59:59.000Z

211

118-K-1 Burial Ground - Hanford Site  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Receiving and Processing Facility Waste Sampling and Characterization Facility Waste Treatment Plant 118-K-1 Burial Ground Email Email Page | Print Print Page |Text Increase...

212

White House budget to ground SOFIA  

Science Journals Connector (OSTI)

... in to make up the difference, the cuts would ground the aeroplane, a modified Boeing 747 that carries a 2.5-metre telescope. ...

Alexandra Witze

2014-03-04T23:59:59.000Z

213

Programmatic Environmental Impact Statement for Ground Water...  

Broader source: Energy.gov (indexed) [DOE]

Environmental Impact Statement for Ground Water Volumes I & II (October 1996) Optical character recognition has been applied to these files, but full search capabilities...

214

Final Environmental Assessment of Ground Water Compliance at the Slick Rock, Colorado, UMTRA Project Site  

Broader source: Energy.gov (indexed) [DOE]

58 58 Environmental Assessment of Ground Water Compliance at the Slick Rock, Colorado, UMTRA Project Sites Final February 2003 Prepared by U.S. Department of Energy Grand Junction Office Grand Junction, Colorado Work Performed Under DOE Contract No. DE-AC13-02GJ79491 DOE Grand Junction Office EA of Ground Water Compliance at the Slick Rock Sites February 2003 Final Page iii Contents Page Acronyms and Abbreviations...........................................................................................................v Executive Summary...................................................................................................................... vii 1.0 Introduction.............................................................................................................................1

215

Ground Gravity Survey At Coso Geothermal Area (1990) | Open Energy  

Open Energy Info (EERE)

Coso Geothermal Area (1990) Coso Geothermal Area (1990) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Gravity Survey At Coso Geothermal Area (1990) Exploration Activity Details Location Coso Geothermal Area Exploration Technique Ground Gravity Survey Activity Date 1990 Usefulness not indicated DOE-funding Unknown Exploration Basis To identify features related to the heat source and to seek possible evidence for an underlying magma chamber Notes 2D and 3D gravity modeling was done using gridded Bouguer gravity data covering a 45 by 45 km region over the Coso geothermal area. Isostatic and terrain corrected Bouguer gravity data for about 1300 gravity stations were obtained from the US Geological Survey. After the data were checked, the gravity values were gridded at 1 km centers for the area of interest

216

GLAST and Ground-Based Gamma-Ray Astronomy  

SciTech Connect (OSTI)

The launch of the Gamma-ray Large Area Space Telescope (GLAST) in 2007 will open the possibility of combined studies of astrophysical sources with existing ground-based VHE {gamma}-ray experiments such as H.E.S.S., VERITAS and MAGIC. Ground-based {gamma}-ray observatories provide complementary capabilities for spectral, temporal, spatial and population studies of high-energy {gamma}-ray sources. Joint observations cover a huge energy range, from 20 MeV to over 50 TeV. The LAT will survey the entire sky every three hours, allowing us to perform long-term monitoring of variable sources under uniform observation conditions and to detect flaring sources promptly. Imaging atmospheric Cherenkov telescopes (IACTs) will complement these observations with high-sensitivity pointed observations on regions of interest.

Funk, S.; Carson, J.E.; Giebels, B.; Longo, F.; McEnery, J.E.; Paneque, D.; Reimer, O.; Reyes, L.C.

2007-10-10T23:59:59.000Z

217

10 years of operation of the Upper Tuloma hydroelectric plant  

Science Journals Connector (OSTI)

1. The high quality of the construction work and the fact that the structures were placed in operation under exc...

K. P. Bogoyavlenskii; G. I. Zhelvakov; A. S. Zabara

1975-03-01T23:59:59.000Z

218

Ground water contamination in the United States  

Science Journals Connector (OSTI)

...volume of ground water in storage exceeds the vol-ume...geo-thermal water; intruded seawater; water affected by evapotranspiration...pressure and the volume in storage may fluctuate according...Estimates of ground water in storage in the United States...communities have over-pumped their freshwater aquifers...

VI Pye; R Patrick

1983-08-19T23:59:59.000Z

219

Ground Turkey and Potato Plate Ingredients  

E-Print Network [OSTI]

Ground Turkey and Potato Plate Ingredients: 1 onion 1/2 pound ground turkey 1 cup ketchup, low sodium 4 medium potatoes 4 ounces cheddar cheese, low-fat Directions 1. Cut the ends off of the onion. Meanwhile pierce potatoes in several places with fork. Place on baking dish in microwave oven. Microwave

Liskiewicz, Maciej

220

Ground water provides drinking water, irrigation for  

E-Print Network [OSTI]

Ground water provides drinking water, irrigation for crops and water for indus- tries. It is also connected to surface waters, and maintains the flow of rivers and streams and the level of wetlands- tion of those along Lake Michigan, most communi- ties, farms and industries still rely on ground water

Saldin, Dilano

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Ground Source Heat Pumps | Open Energy Information  

Open Energy Info (EERE)

Ground Source Heat Pumps Ground Source Heat Pumps Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Ground Source Heat Pumps Geothermal Technologies There are many types of Geothermal Technologies that take advantage of the earth's heat: Hydrothermal Systems Enhanced Geothermal Systems (EGS) Sedimentary Geothermal Systems Co-Produced Geothermal Systems Geothermal Direct Use Ground Source Heat Pumps GSHP Links Related documents and websites An Information Survival Kit for the Prospective Geothemral Heat Pump Owner List of Heat Pumps Incentives List of Ground Source Heat Pumps Incentives Policy Makers' Guidebook for Geothermal Heating and Cooling Various ways to configure a geothermal heat pump system. (Source: The Geo-Heat Center's Survival Kit for the Prospective Geothemral Heat Pump

222

Ground Source Heat Pumps | Open Energy Information  

Open Energy Info (EERE)

Ground Source Heat Pumps Ground Source Heat Pumps (Redirected from Geothermal Heat Pumps) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Ground Source Heat Pumps Geothermal Technologies There are many types of Geothermal Technologies that take advantage of the earth's heat: Hydrothermal Systems Enhanced Geothermal Systems (EGS) Sedimentary Geothermal Systems Co-Produced Geothermal Systems Geothermal Direct Use Ground Source Heat Pumps GSHP Links Related documents and websites An Information Survival Kit for the Prospective Geothemral Heat Pump Owner List of Heat Pumps Incentives List of Ground Source Heat Pumps Incentives Policy Makers' Guidebook for Geothermal Heating and Cooling Various ways to configure a geothermal heat pump system. (Source: The Geo-Heat Center's Survival Kit for the Prospective Geothemral Heat Pump

223

San Francisco Operations Office  

Office of Legacy Management (LM)

San Francisco Operations Office San Francisco Operations Office 1333 Broadway Oakland, California 94612 Dr. Joseph 0. Ward, Chief Radiological Health Section Department of Health Services 744 P Street Sacramento, California, 95814 SUBJECT: Certification Docket of Gilman Hall Dear Dr. Ward: The Department of Energy (DOE) has completed and reviewed the remedial ac- tions of Gilman Hall located at the University of California, Berkeley, California. Based on this review, DOE certifies that the condition of Gilman Hall is radiologically acceptable for restricted use under the con- trols of the University of California's State General License 1333-62 pro- vided that the University's Office of Environmental Health and Safety con- tinues to survey Gilman Hall and monitor whenever remodeling or renovation

224

AUTHORIZATION TO CONTINUE OPERATION OF  

Broader source: Energy.gov (indexed) [DOE]

Non-competitive Extension] Non-competitive Extension] AUTHORIZATION TO CONTINUE OPERATION OF THE_[insert the name of the laboratory/site/facility]___ UNDER A MANAGEMENT AND OPERATING CONTRACT The _[insert the name of the laboratory/site/facility]_ is currently managed and operated by _[insert the name of the contractor]_ for the Department of Energy under DOE contract _[insert contract number]._This contract is a Management and Operating (M&O) contract as defined in Federal Acquisition Regulation (FAR) Subpart 17.6. The current contract and the determination authorizing the M&O form of contract expire on _[insert the expiration date]_. A non-competitive extension is currently being pursued in accordance with FAR 6.301. [In one or two sentences, briefly describe the

225

Protection Program Operations  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order establishes requirements for the management and operation of the DOE Federal Protective Forces (FPF), Contractor Protective Forces (CPF), and the Physical Security of property and personnel under the cognizance of DOE. Cancels DOE M 470.4-2A, DOE M 470.4-3A, and DOE M 470.4-8. Appendix C Safeguards and Security Alarm Management and Control Systems, of DOE M 470.4-2A, is retained and incorporated into this Order as Attachment 3, Annex 1.

2011-06-29T23:59:59.000Z

226

Ground Source Heat Pump Data Mining Research Project | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Ground Source Heat Pump Data Mining Ground Source Heat Pump Data Mining Research Project Ground Source Heat Pump Data Mining Research Project The U.S. Department of Energy is currently conducting research into ground source heat pump (GSHP) data mining. This project seeks to build public awareness of GSHP technology through the development of case studies outlining costs and benefits. Project Description This project seeks to produce in-depth case studies on the costs and benefits of American Recovery and Reinvestment Act -funded GSHP demonstration projects, including cross-cutting summaries of lessons learned and best practices for design, installation, and operation. Project Partners Research is being undertaken between the Department of Energy and Oak Ridge National Laboratory. Project Goals

227

National Aeronautics and Space Administration Human Exploration & Operations  

E-Print Network [OSTI]

)/Ground Operations. · Continue strong momentum on Commercial activities. · Conduct remaining launches in LaunchNational Aeronautics and Space Administration Human Exploration & Operations Reorganization Status capabilities to conduct NASA's aeronautics and space activities. 6. Share NASA with the public, educators

Waliser, Duane E.

228

Definition: Ground Electromagnetic Techniques | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Ground Electromagnetic Techniques Jump to: navigation, search Dictionary.png Ground Electromagnetic Techniques Ground electromagnetic techniques measure electromagnetic fields in order to determine subsurface electrical resistivity with the earth surface as the observation point.[1] View on Wikipedia Wikipedia Definition The electromagnetic force is one of the four fundamental interactions in nature, the other three being the strong interaction, the weak interaction, and gravitation. This force is described by electromagnetic fields, and has innumerable physical instances including the interaction of electrically charged particles and the interaction of uncharged magnetic force fields with electrical conductors. The word

229

Ground Electromagnetic Techniques | Open Energy Information  

Open Energy Info (EERE)

Ground Electromagnetic Techniques Ground Electromagnetic Techniques Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Ground Electromagnetic Techniques Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Geophysical Techniques Exploration Sub Group: Electrical Techniques Parent Exploration Technique: Electromagnetic Techniques Information Provided by Technique Lithology: Rock composition, mineral and clay content Stratigraphic/Structural: Detection of permeable pathways, fracture zones, faults Hydrological: Resistivity influenced by porosity, grain size distribution, permeability, fluid saturation, fluid type and phase state of the pore water Thermal: Resistivity influenced by temperature Dictionary.png

230

Ground-Based and Airborne (PMS 2-D Probe Canister-Mounted) 183 GHz Water  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ground-Based and Airborne (PMS 2-D Probe Canister-Mounted) 183 GHz Water Ground-Based and Airborne (PMS 2-D Probe Canister-Mounted) 183 GHz Water Vapor Radiometer Pazmany, Andrew ProSensing Inc. Category: Instruments ProSensing Inc. has developed a G-band (183 GHz, 1.5 mm wavelength) water vapor radiometer (GVR) for the measurement of low concentrations of atmospheric water vapor and liquid water. The instrument's precipitable water vapor measurement precision is approximately 0.01 mm in dry (<2 mm vapor column) conditions. The ground-based version of the instrument was first deployed at ProSensing's facility in Amherst, MA in February 2005, then at the North Slope of Alaska DOE ARM site in Barrow AK in April 2005, where it has been continuously operating since. An airborne version, designed to operate from a standard PMS 2-D probe canister, is now being

231

Grounded Renewable Energy | Open Energy Information  

Open Energy Info (EERE)

Grounded Renewable Energy Grounded Renewable Energy Jump to: navigation, search Name Grounded Renewable Energy Place Carbondale, Colorado Zip 81623 Sector Renewable Energy, Solar Product Grounded Renewable Energy designs turn-key solar systems for homes and businesses in Colorado. Coordinates 41.573959°, -75.501361° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.573959,"lon":-75.501361,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

232

Ground Insulation Measurement in AC IT Systems  

Science Journals Connector (OSTI)

In the chapter there is presented general information on physical nature of network-to-ground insulation. Sense of “insulation equivalent resistance” parameter is explained. A method of insulation resistances-to-...

Piotr Olszowiec

2013-01-01T23:59:59.000Z

233

Superfund record of decision (EPA Region 6): Double Eagle Refinery Site, operable unit 2, Oklahoma City, OK, April 19, 1994  

SciTech Connect (OSTI)

The decision document presents the selected remedial action for the Double Eagle Refinery Site (DER site), in Oklahoma City, Oklahoma, for the Ground Water Operable Unit. Principal threat wastes include `pools` of dense non-aqueous phase liquids (DNAPLs) submerged beneath the ground water or in fractured bedrock. The Ground Water Operable Unit (GOU) addresses the principal threat at the site by monitoring the ground water to ensure that the contaminant levels are reduced with time due to natural attenuation, once the surface contamination is addressed, so that the surface contamination will no longer provide a source of contamination to the ground water.

NONE

1995-02-01T23:59:59.000Z

234

Shielding and grounding in large detectors  

SciTech Connect (OSTI)

Prevention of electromagnetic interference (EMI), or ``noise pickup,`` is an important design aspect in large detectors in accelerator environments. Shielding effectiveness as a function of shield thickness and conductivity vs the type and frequency of the interference field is described. Noise induced in transmission lines by ground loop driven currents in the shield is evaluated and the importance of low shield resistance is emphasized. Some measures for prevention of ground loops and isolation of detector-readout systems are discussed.

Radeka, V.

1998-09-01T23:59:59.000Z

235

Baseline risk assessment of ground water contamination at the Uranium Mill Tailings Site near Riverton, Wyoming  

SciTech Connect (OSTI)

This Risk Assessment evaluated potential impacts to public health or the environment caused by ground water contamination at the former uranium mill processing site. In the first phase of the U.S. Department of Energy`s Uranium Mill Tailings Remedial Action (UMTRA) Project, the tailing and other contaminated material at this site were placed in a disposal cell near the Gas Hills Plant in 1990. The second phase of the UMTRA Project is to evaluate ground water contamination. This risk assessment is the first site-specific document to evaluate potential health and environmental risks for the Riverton site under the Ground Water Project; it will help determine whether remedial actions are needed for contaminated ground water at the site.

Not Available

1994-09-01T23:59:59.000Z

236

Calculation of ground state energy of harmonically confined two dipolar fermions  

E-Print Network [OSTI]

We calculate the ground state energies of a system of two dipolar fermions trapped in a harmonic oscillator potential. The dipoles are assumed to be aligned parallel to each other. We perform the calculations of ground state energy as a function of strength of interaction between two fermions by employing variational method with Hylleraas-like explicitly correlated wave function. Furthermore, we perform calculations of ground state energy within Hartree-Fock approximation and the magnitude of correlation energy is estimated by subtracting these results from the corresponding wave function based results. We also carry out calculations of ground state energies within the realm of density functional theory by using recently reported expressions for exchange and correlation energies under local density approximation. By comparing correlated wave function based results with those obtained using density functional theory approach we examine the role of fermion-fermion correlation and assess the accuracy of local de...

Das, Amit K

2014-01-01T23:59:59.000Z

237

Superfund record of decision (EPA Region 8): Ellsworth Air Force Base, Operable Unit 1, Rapid City, SD, May 10, 1996  

SciTech Connect (OSTI)

This ROD is for remedial action at OU-1. The selected alternative, source area soil and ground-water treatment, includes: Continued operation of the interim remedial action (IRA) which consisted of contaminated ground-water removal, soil vapor extraction (SVE), and treatment; Installation of additional SVE wells within the historical burn-pit area to be added to the existing IRA SVE system; Removal of contaminated ground water using additional ground-water wells and collection trenches to be added to the IRA ground-water recovery system; Treatment of ground water at the existing IRA treatment plant; and Institutional controls for the area.

NONE

1996-10-01T23:59:59.000Z

238

Feasibility study of a nonequilibrium MHD accelerator concept for hypersonic propulsion ground testing  

SciTech Connect (OSTI)

A National Aeronautics and Space Administration (NASA) funded research study to evaluate the feasibility of using magnetohydrodynamic (MHD) body force accelerators to produce true air simulation for hypersonic propulsion ground testing is discussed in this paper. Testing over the airbreathing portion of a transatmospheric vehicle (TAV) hypersonic flight regime will require high quality air simulation for actual flight conditions behind a bow shock wave (forebody, pre-inlet region) for flight velocities up to Mach 16 and perhaps beyond. Material limits and chemical dissociation at high temperature limit the simulated flight Mach numbers in conventional facilities to less than Mach 12 for continuous and semi-continuous testing and less than Mach 7 for applications requiring true air chemistry. By adding kinetic energy directly to the flow, MHD accelerators avoid the high temperatures and pressures required in the reservoir region of conventional expansion facilities, allowing MHD to produce true flight conditions in flight regimes impossible with conventional facilities. The present study is intended to resolve some of the critical technical issues related to the operation of MHD at high pressure. Funding has been provided only for the first phase of a three to four year feasibility study that would culminate in the demonstration of MHD acceleration under conditions required to produce true flight conditions behind a bow shock wave to flight Mach numbers of 16 or greater. MHD critical issues and a program plan to resolve these are discussed.

Lee, Ying-Ming; Simmons, G.A.; Nelson, G.L. [MSE Inc., Butte, MT (United States)

1995-12-31T23:59:59.000Z

239

Idaho Operations Office | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Idaho Operations Idaho Operations Office Idaho Operations Office Idaho Operations Office INL combines the expertise of government, industry and academia in a single laboratory under the leadership of Battelle Energy Alliance (BEA), a team comprised of Battelle Memorial Institute, Washington Group International, BWXT Services, Inc., the Electric Power Research Institute and Massachusetts Institute of Technology. BEA manages the laboratory under a Management and Operating contract. This contract requires: Safe and efficient operation of all INL facilities. Cost reduction by better use of existing facilities and elimination of under-utilized or unneeded facilities. More cost effective accomplishment of mission objectives by use of upgraded and new infrastructure. The ongoing effort needed to maintain federal facilities and infrastructure

240

Formal Specification of Operating System Operations  

E-Print Network [OSTI]

Formal Specification of Operating System Operations Dan Zhou Department of Computer Science.black@nist.gov This paper describes the development of a formal specification for a secure operating system architecture operations. We also provide a uniform environment for system commands that change the security state

Black, Paul E.

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

GROUND PLANE INSULATION FAILURE IN THE FIRST TPC SUPERCONDUCTING COIL  

E-Print Network [OSTI]

is WIUUTEO GROUND PLANE INSULATION FAILURE IN THE FIRST TPCOn August 27, 1980, an insulation failure occurred dt-ringby a failure uf ground plane insulation. ACKNOWLEDGMENTS The

Green, M.A.

2010-01-01T23:59:59.000Z

242

Ground heat exchanger design for direct geothermal energy systems .  

E-Print Network [OSTI]

??Direct geothermal energy systems use the ground to heat and cool buildings. Ground-source heat pump (GSHP) systems are the most widespread form of direct geothermal… (more)

COLLS, STUART

2013-01-01T23:59:59.000Z

243

Recovery Act - Geothermal Technologies Program:Ground Source...  

Broader source: Energy.gov (indexed) [DOE]

Recovery Act - Geothermal Technologies Program:Ground Source Heat Pumps Recovery Act - Geothermal Technologies Program:Ground Source Heat Pumps A detailled description of the...

244

Water Quality Surface and Ground | Open Energy Information  

Open Energy Info (EERE)

Ground Jump to: navigation, search Retrieved from "http:en.openei.orgwindex.php?titleWaterQualitySurfaceandGround&oldid612197" Category: NEPA Resources...

245

EPA - Ground Water Discharges (EPA's Underground Injection Control...  

Open Energy Info (EERE)

EPA - Ground Water Discharges (EPA's Underground Injection Control Program) webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: EPA - Ground Water...

246

Hybrid Ground Source System Analysis and Tool Development | Department...  

Broader source: Energy.gov (indexed) [DOE]

Hybrid Ground Source System Analysis and Tool Development Hybrid Ground Source System Analysis and Tool Development Project objectives: 1. Compile filtered hourly data for three...

247

Heat pumps and under floor heating as a heating system for Finnish low-rise residential buildings.  

E-Print Network [OSTI]

??In bachelor’s thesis the study of under floor heating system with ground source heat pump for the heat transfers fluid heating is considered. The case… (more)

Chuduk, Svetlana

2010-01-01T23:59:59.000Z

248

Remedial investigation work plan for Bear Creek Valley Operable Unit 1 (S-3 Ponds, Boneyard/Burnyard, Oil Landfarm, Sanitary Landfill 1, and the Burial Grounds, including Oil Retention Ponds 1 and 2) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Volume 1, Main text  

SciTech Connect (OSTI)

The intent and scope of the work plan are to assemble all data necessary to facilitate selection of remediation alternatives for the sites in Bear Creek Valley Operable Unit 1 (BCV OU 1) such that the risk to human health and the environment is reduced to acceptable levels based on agreements with regulators. The ultimate goal is to develop a final Record Of Decision (ROD) for all of the OUs in BCV, including the integrator OU. However, the initial aim of the source OUs is to develop a ROD for interim measures. For source OUs such as BCV OU 1, data acquisition will not be carried out in a single event, but will be carried out in three stages that accommodate the schedule for developing a ROD for interim measures and the final site-wide ROD. The three stages are as follows: Stage 1, Assemble sufficient data to support decisions such as the need for removal actions, whether to continue with the remedial investigation (RI) process, or whether no further action is required. If the decision is made to continue the RI/FS process, then: Stage 2, Assemble sufficient data to allow for a ROD for interim measures that reduce risks to the human health and the environment. Stage 3, Provide input from the source OU that allows a final ROD to be issued for all OUs in the BCV hydrologic regime. One goal of the RI work plan will be to ensure that sampling operations required for the initial stage are not repeated at later stages. The overall goals of this RI are to define the nature and extent of contamination so that the impact of leachate, surface water runoff, and sediment from the OU I sites on the integrator OU can be evaluated, the risk to human health and the environment can be defined, and the general physical characteristics of the subsurface can be determined such that remedial alternatives can be screened.

Not Available

1993-09-01T23:59:59.000Z

249

Ground Water Compliance Action Plan for the Old Rifle, Colorado, UMTRA Project Site  

Office of Legacy Management (LM)

GJO-2000-177-TAR GJO-2000-177-TAR MAC-GWRFL 1.9 Ground Water Compliance Action Plan for the Old Rifle, Colorado, UMTRA Project Site December 2001 Work Performed Under DOE Contract No. DE-AC13-96GJ87335 for the U.S. Department of Energy Approved for public release; distribution is unlimited. GJO-2000-177-TAR MAC-GWRFL 1.9 Ground Water Compliance Action Plan for the Old Rifle, Colorado, UMTRA Project Site December 2001 Prepared by U.S. Department of Energy Grand Junction Office Grand Junction, Colorado Project Number UGW-511-0017-12-000 Document Number U0066302 Work Performed under DOE Contract No. DE-AC13-96GJ87335 Document Number U0066302 Contents DOE/Grand Junction Office Ground Water Compliance Action Plan for Old Rifle, Colorado

250

(sanitary) landfill operator  

Science Journals Connector (OSTI)

(sanitary) landfill operator, Müllkippenbetreiber m, Mülldeponiebetreiber, Kippenbetreiber, Deponiebetreiber

2014-08-01T23:59:59.000Z

251

Operations Directorate (OPS Directorate)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Operations Directorate (OPS Directorate) Operations Directorate (OPS Directorate) Purpose A group chartered by the Associate Laboratory Director for the Advanced Photon Source that includes the responsible Division Directors and other appropriate APS operations personnel. The Operations Directorate collectively coordinates operating decisions that affect the facility as a whole and establishes both long- and short-term schedules, including scheduled maintenance and facility improvement periods. The Operations Directorate is the APS forum in which decisions regarding operations are discussed: These include, but are not limited to: Safety issues related to operations Operational Schedule Global operating parameters within the defined and approved operational and safety envelopes, such as energy, maximum circulating beam

252

A review of solar photovoltaic panel cooling systems with special reference to Ground coupled central panel cooling system (GC-CPCS)  

Science Journals Connector (OSTI)

Abstract The efficiency of wafer-based crystalline as well as Thin film Solar photovoltaic cells get reduced with increase of panel temperature. It is noted that the efficiency drops by about 0.5% for increase of 1 °C of panel temperature. It is necessary to operate them at low temperatures in order to keep the PV module electrical efficiency at acceptable level. Therefore need for a low-cost cooling system for the Solar panels is felt. The cooling of Solar PV panels is a problem of great practical significance. It has the potential to reduce the cost of solar energy in three ways. First, cooling can improve the electrical production of standard flat plate PV modules. Second, cooling makes possible the use of concentrating PV systems. Finally, the heat removed by the PV cooling system can be used for domestic or industrial use. Various Solar PV panel cooling systems have been developed in past. A new system for cooling of Solar PV panels called the Ground-Coupled Central Panel Cooling System (GC-CPCS) is installed and operational at the Energy Park of Rajiv Gandhi Proudyogiki Vishwavidyalaya (RGPV), Bhopal, India. This paper discusses various Solar PV panel cooling technologies and the testing and performance of the newly developed Ground-Coupled Central Panel Cooling System (GC-CPCS). This study is unique in three ways. First, it introduces the concept of Central cooling of Solar PV panels. Second, Ground Coupled Heat Exchanger is used for the first time in any Solar PV Panel Cooling System. Third, the testing is done on site under actual solar irradiance.

Amit Sahay; V.K. Sethi; A.C. Tiwari; Mukesh Pandey

2015-01-01T23:59:59.000Z

253

Hermitian Young operators  

SciTech Connect (OSTI)

Starting from conventional Young operators, we construct Hermitian operators which project orthogonally onto irreducible representations of the (special) unitary group.

Keppeler, Stefan, E-mail: stefan.keppeler@uni-tuebingen.de [Mathematisches Institut, Universität Tübingen, Auf der Morgenstelle 10, 72076 Tübingen (Germany)] [Mathematisches Institut, Universität Tübingen, Auf der Morgenstelle 10, 72076 Tübingen (Germany); Sjödahl, Malin, E-mail: malin.sjodahl@thep.lu.se [Department of Astronomy and Theoretical Physics, Lund University, Sölvegatan 14A, 223 62 Lund (Sweden)] [Department of Astronomy and Theoretical Physics, Lund University, Sölvegatan 14A, 223 62 Lund (Sweden)

2014-02-15T23:59:59.000Z

254

Groundwater transport modeling of constituents originating from the Burial Grounds Complex  

SciTech Connect (OSTI)

The Savannah River Site (SRS), operates a number of sites for the land disposal of various leachable radionuclide, organic, and inorganic wastes. Located within the General Separations Area (GSA) of SRS are the Low Level Radioactive Waste Disposal Facility (LLRWDF) and the Old Burial Ground (OBG). A portion of the LLRWDF has been designated as the Mixed Waste Management Facility (MWMF). The OBG began receiving waste in 1952 and was closed in 1974. Various wastes, including transuranic, intermediate and low level beta-gamma, and solvents, were received during this period of operation. In 1969, prior to the closing of the OBG, a portion of the MWMF/LLRWDF (the MWMF) began receiving waste. GeoTrans, Inc. was contracted by WSRC to conduct a numerical modeling study to assess groundwater flow and contaminant transport in the vicinity of the MWMF in support of an Alternate Concentration Limits demonstration for the Part B permit. The project was divided into two phases: development of a groundwater flow model of the hydrogeologic system underlying the MWMF which includes the entire GSA, and development of a solute transport model to assess migration of 19 designated constituents of concern (COCs) over a period 30 years into the future. The first phase was completed in May of 1992 and the results documented in GeoTrans (1992). That report serves as the companion volume to the present contaminant transport modeling report. The transport study is intended to develop predictions of concentration and mass flux of the 19 COCs at downgradient exposure points over the 30 year period of interest. These results are to be used in human health and ecological risk assessments which are also being performed in support of the Part B permit.

Andersen, P.F.; Shupe, M.G.; Spalding, C.P. [GeoTrans, Inc., Sterling, VA (US)

1992-10-30T23:59:59.000Z

255

WestSolarGroundMount City of Phoenix/ASU West  

E-Print Network [OSTI]

Fletcher WestSolarGroundMount Lawn Field City of Phoenix/ASU West South Fields Community Park Lecture Hall KIVA 3E Las Casas Residence Hall CASA 3C · Student Housing · Student Housing Sands Classroom for exact locations. N S W E Z Under Construction WC PTS CSC South Zone Park Zone South Zone South Zone

256

Definition: Ground Gravity Survey | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Ground Gravity Survey Jump to: navigation, search Dictionary.png Ground Gravity Survey The ground gravitational method is the study of the distribution of mass in the subsurface with the observation point at the earth's surface.[1] View on Wikipedia Wikipedia Definition A gravity anomaly is the difference between the observed acceleration of a planet's gravity and a value predicted from a model. A location with a positive anomaly exhibits more gravity than predicted, while a negative anomaly exhibits a lower value than predicted. References ↑ http://www.amazon.com/Geophysical-Field-Theory-Three-Volume-Gravitational/dp/0124020410 Ret Like Like You like this.Sign Up to see what your friends like.

257

GroundedPower Inc | Open Energy Information  

Open Energy Info (EERE)

GroundedPower Inc GroundedPower Inc Jump to: navigation, search Name GroundedPower Inc Place Gloucester, Massachusetts Zip 1930 Product Massachusetts-based company developing home and building energy management systems via IP-based software. Coordinates 37.413962°, -76.526305° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.413962,"lon":-76.526305,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

258

Ground Gravity Survey | Open Energy Information  

Open Energy Info (EERE)

Ground Gravity Survey Ground Gravity Survey Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Ground Gravity Survey Details Activities (48) Areas (34) Regions (2) NEPA(2) Exploration Technique Information Exploration Group: Geophysical Techniques Exploration Sub Group: Gravity Techniques Parent Exploration Technique: Gravity Techniques Information Provided by Technique Lithology: Distribution of density in the subsurface enables inference of rock type. Stratigraphic/Structural: Delineation of steeply dipping formations, geological discontinuities and faults, intrusions and large-scale deposition of silicates due to hydrothermal activity. Hydrological: Density of sedimentary rocks are strongly influenced by fluid contained within pore space. Dry bulk density refers to the rock with no moisture, while the wet bulk density accounts for water saturation; fluid content may alter density by up to 30%.(Sharma, 1997)

259

Appendix B Ground Water Management Policy  

Office of Legacy Management (LM)

Ground Water Management Policy Ground Water Management Policy for the Monticello Mill Tailings Site and Adjacent Areas This page intentionally left blank Docun~ent Number Q0029500 Appendix B State of Utah DEPARTblENT OF NATURAL RESOURCES DIVISION OF WATER RIGHTS Ground-Water Management Policy for the Mot~ticello Mill Tailings Site and Adjacent Areas The Monticello Mill Tailings Site is on the southeast portion of the tovm of Monticello in Sectton 36, T33S, K23E and Section 31, i33S. R24E, SLB&M. The mill site was used from 1942 to 1960 in the processing of uranium and vanadium. The U.S. Department of Energy (DOE) is currently cleaning up the site. The site is in the small canyon that forms the drainage for South Creek. The general direction of water flow, of both surface streams and the shallow

260

Transmission line modeling with explicit grounding representation  

Science Journals Connector (OSTI)

This paper presents a new model of an overhead transmission line for electromagnetic transient computations. The unique feature of the model is the explicit representation of the tower grounding configuration and terminal substation grounds. Other properties of the model are: (1) accurate frequency dependent parameter representation from DC to several MHz; (2) explicit modeling of line asymmetries; and (3) high numerical efficiency. The model implementation is based on the solution of the transmission line differential equations resulting in a set of step response functions, forming a matrix. The step response matrix is utilized in a time domain simulation of electric power networks by a linear convolution scheme. The transmission line model is validated with actual system test data. The model is useful for computing the ground potential rise of transmission towers due to lightning or switching surges, insulation stress, etc. Typical applications are described in the paper.

G.J. Cokkinides; A.P.Sakis Meliopoulos

1988-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Corrective Action Investigation Plan for Corrective Action Unit 406: Area 3 Building 03-74 and Building 03-58 Under ground Discharge Points and Corrective Action Unit 429: Area 3 Building 03-55 and Area 9 Building 09-52 Underground Discharge Points, Tonopah Test Range, Nevada  

SciTech Connect (OSTI)

This Corrective Action Investigation Plan (CAIP) has been developed in accordance with the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the US Department of Energy, Nevada Operations Office (DOE/NV); the State of Nevada Division of Environmental Protection (NDEP); and the US Department of Defense (FFACO, 1996). The CAIP is a document that provides or references all of the specific information for investigation activities associated with Corrective Action Units (CAUs) or Corrective Action Sites (CASs). According to the FFACO (1996), CASs are sites potentially requiring corrective action(s) and may include solid waste management units or individual disposal or release sites. Corrective Action Units consist of one or more CASs grouped together based on geography, technical similarity, or agency responsibility for the purpose of determining corrective actions. This CAIP contains the environmental sample collection objectives and the criteria for conducting site investigation activities at the Underground Discharge Points (UDPs) included in both CAU 406 and CAU 429. The CAUs are located in Area 3 and Area 9 of the Tonopah Test Range (TTR). The TTR, included in the Nellis Air Force Range, is approximately 255 kilometers (km) (140 miles [mi]) northwest of Las Vegas, Nevada.

DOE/NV

1999-05-20T23:59:59.000Z

262

Albuquerque Operations Office  

Office of Legacy Management (LM)

%r © J~4 %r © J~4 aDepartment of Energy Albuquerque Operations Office P.O. Box 5400 Albuquerue. New Mexico 87118 JUIl 0 198 Vicinity Property No. CA-401 _ U l Address; Mayer Street Bridgeville, Pennsylvania Cyclops Corporation 650 Washington Road Pittsburgh, Pennsylvania 15228 Dear Sir: Under the Uranium Mill Tailings Radiation Control Act of 1978, Public Law 95-604, the Department of Energy (DOE) is authorized to conduct remedial action at properties contaminated with residual radioactive material from inactive uranium mill sites. Evaluation of your property identified above has revealed the presence of residual radioactive material in excess of standards established by the Environmental Protection Agency (EPA). Therefore, your property has been formally included by DOE for remedial action in the Uranium Mill Tailings

263

Direct and indirect capture of carriers into the lasing ground state and the light-current characteristic of quantum dot lasers  

SciTech Connect (OSTI)

We calculate the light-current characteristic (LCC) of a quantum dot (QD) laser under the conditions of both direct and indirect capture of carriers from the optical confinement layer into the lasing ground state in QDs. We show that direct capture is a dominant process determining the ground-state LCC. Only when direct capture is slow, the role of indirect capture (capture into the QD excited state and subsequent intradot relaxation to the ground state) becomes important.

Wu, Yuchang, E-mail: yuchangw@vt.edu; Asryan, Levon V., E-mail: asryan@vt.edu [Virginia Polytechnic Institute and State University, Blacksburg, Virginia 24061 (United States)

2014-03-14T23:59:59.000Z

264

Simulation and Optimization of Wind Farm Operations under Stochastic Conditions  

E-Print Network [OSTI]

generation model, wind speed model, and maintenance model. We provide practical insights gained by examining di erent maintenance strategies. To the best of our knowledge, our simulation model is the rst discrete-event simulation model for wind farm...

Byon, Eunshin

2011-08-08T23:59:59.000Z

265

Operation Planning of Multiparcel Tankers under Fuel Price Uncertainty  

Science Journals Connector (OSTI)

They may deviate slightly from their normal voyage plans, incur necessary port dues, or even delay the transit through a canal to refuel at a port with attractively priced fuel. ... Most commercial marine vessels use fuels with 180 cst, 380 cst, and 500 cst viscosities with 380 cst being the most common. ... The fuel prices for these options are uncertain except at the end of leg 0. Since the tanker may be at a port, or will reach the next port shortly after time zero, it is reasonable to assume that the fuel price of each refueling option after leg 0 is fixed and known. ...

H. C. Oh; I. A. Karimi

2010-05-26T23:59:59.000Z

266

Seismic fragility formulations for segmented buried pipeline systems including the impact of differential ground subsidence  

SciTech Connect (OSTI)

Though Differential Ground Subsidence (DGS) impacts the seismic response of segmented buried pipelines augmenting their vulnerability, fragility formulations to estimate repair rates under such condition are not available in the literature. Physical models to estimate pipeline seismic damage considering other cases of permanent ground subsidence (e.g. faulting, tectonic uplift, liquefaction, and landslides) have been extensively reported, not being the case of DGS. The refinement of the study of two important phenomena in Mexico City - the 1985 Michoacan earthquake scenario and the sinking of the city due to ground subsidence - has contributed to the analysis of the interrelation of pipeline damage, ground motion intensity, and DGS; from the analysis of the 48-inch pipeline network of the Mexico City's Water System, fragility formulations for segmented buried pipeline systems for two DGS levels are proposed. The novel parameter PGV{sup 2}/PGA, being PGV peak ground velocity and PGA peak ground acceleration, has been used as seismic parameter in these formulations, since it has shown better correlation to pipeline damage than PGV alone according to previous studies. By comparing the proposed fragilities, it is concluded that a change in the DGS level (from Low-Medium to High) could increase the pipeline repair rates (number of repairs per kilometer) by factors ranging from 1.3 to 2.0; being the higher the seismic intensity the lower the factor.

Pineda Porras, Omar Andrey [Los Alamos National Laboratory; Ordaz, Mario [UNAM, MEXICO CITY

2009-01-01T23:59:59.000Z

267

Optimal operating strategy for a storage facility  

E-Print Network [OSTI]

In the thesis, I derive the optimal operating strategy to maximize the value of a storage facility by exploiting the properties in the underlying natural gas spot price. To achieve the objective, I investigate the optimal ...

Zhai, Ning

2008-01-01T23:59:59.000Z

268

Designing, selecting and installing a residential ground-source heat pump system  

SciTech Connect (OSTI)

It's a compelling proposition: Use the near-constant-temperature heat underground to heat and cool your home and heat domestic water, slashing your energy bills. Yet despite studies demonstrating significant energy savings from ground-source heat pump (GSHP) systems, their adoption has been hindered by high upfront costs. Fewer than 1% of US homes use a GSHP system. However, compared to a minimum-code-compliant conventional space-conditioning system, when properly designed and installed, a GSHP retrofit at current market prices offers simple payback of 4.3 years on national average, considering existing federal tax credits. Most people understand how air-source heat pumps work: they move heat from indoor air to outdoor air when cooling and from outdoor air to indoor air when heating. The ground-source heat pump operates on the same principle, except that it moves heat to or from the ground source instead of outdoor air. The ground source is usually a vertical or horiontal ground heat exchanger. Because the ground usually has a more favorable temperature than ambient air for the heating and cooling operation of the vapor-compression refrigeration cycle, GSHP sysems can operate with much higher energy efficiencies than air-source heat pump systems when properly designed and installed. A GSHP system used in a residual building typically provides space conditioning and hot water and comprises three major components: a water-source heat pump unit designed to operate at a wider range of entering fluid temperatures (typically from 30 F to 110 F, or 1 C to 43 C) than a conventional water-source heat pump unit; a ground heat exchanger (GHX); and distribution systems to deliver hot water to the storage tank and heating or cooling to the conditioned rooms. In most residual GSHP systems, the circulation pumps and associated valves are integrated with the heat pump to circulate the heat-carrier fluid (water or aqueous antifreeze solution) through the heat pump and the GHX. A recent assessment indicates that if 20% of US homes replaced their existing space-conditioning and water-heating systems with properly designed, installed and operated state-of-the-art GSHP systems, it would yield significant benefits each year. These include 0.8 quad British thermal units (Btu) of primary energy savings, 54.3 million metric tons of CO{sub 2} emission reductions, $10.4 billion in energy cost savings and 43.2 gigawatts of reduction in summer peak electrical demand.

Hughes, Patrick [ORNL; Liu, Xiaobing [ORNL; Munk, Jeffrey D [ORNL

2010-01-01T23:59:59.000Z

269

Protection from ground faults in the stator winding of generators at power plants in the Siberian networks  

SciTech Connect (OSTI)

The experience of many years of experience in developing and utilization of ground fault protection in the stator winding of generators in the Siberian networks is generalized. The main method of protection is to apply a direct current or an alternating current with a frequency of 25 Hz to the primary circuits of the stator. A direct current is applied to turbo generators operating in a unit with a transformer without a resistive coupling to the external grid or to other generators. Applying a 25 Hz control current is appropriate for power generation systems with compensation of a capacitive short circuit current to ground. This method forms the basis for protection of generators operating on busbars, hydroelectric generators with a neutral grounded through an arc-suppression reactor, including in consolidated units with generators operating in parallel on a single low-voltage transformer winding.

Vainshtein, R. A., E-mail: vra@tpu.ru [Tomsk Polytechnical University (Russian Federation); Lapin, V. I. [ODU Sibiri (Integrated Dispatcher Control for Siberia), branch of JSC 'SO EES' (Russian Federation); Naumov, A. M.; Doronin, A. V. [JSC NPP 'EKRA' (Russian Federation); Yudin, S. M. [Tomsk Polytechnical University (Russian Federation)

2010-05-15T23:59:59.000Z

270

Store-operate-coherence-on-value  

DOE Patents [OSTI]

A system, method and computer program product for performing various store-operate instructions in a parallel computing environment that includes a plurality of processors and at least one cache memory device. A queue in the system receives, from a processor, a store-operate instruction that specifies under which condition a cache coherence operation is to be invoked. A hardware unit in the system runs the received store-operate instruction. The hardware unit evaluates whether a result of the running the received store-operate instruction satisfies the condition. The hardware unit invokes a cache coherence operation on a cache memory address associated with the received store-operate instruction if the result satisfies the condition. Otherwise, the hardware unit does not invoke the cache coherence operation on the cache memory device.

Chen, Dong; Heidelberger, Philip; Kumar, Sameer; Ohmacht, Martin; Steinmacher-Burow, Burkhard

2014-11-18T23:59:59.000Z

271

Electric Vehicle Site Operator Program  

SciTech Connect (OSTI)

Kansas State University, with funding support from federal, state, public, and private companies, is participating in the Department of Energy's Electric Vehicle Site Operator Program. Through participation is this program, Kansas State is demonstrating, testing, and evaluating electric or hybrid vehicle technology. This participation will provide organizations the opportunity to examine the latest EHV prototypes under actual operating conditions. KSU proposes to purchase one (1) electric or hybrid van and four (4) electric cars during the first two years of this five year program. KSU has purchased one G-Van built by Conceptor Industries, Toronto, Canada and has initiated a procurement order to purchase two (2) Soleq 1992 Ford EVcort stationwagons.

Not Available

1992-01-01T23:59:59.000Z

272

Wideband noise observed at ground level in the auroral region  

SciTech Connect (OSTI)

A sideband noise event was detected at ground level from the Andoya Rocket Range in Norway in January 1989. The signals were observed on four commercial communication receivers (tuned to 159, 515, 905, and 1200 kHz), an ionosonde (200-kHz to 3.5-MHz interference-free observations) and a riometer (32.5 MHz). The event, which occurred during a period of magnetic disturbance near magnetic midnight, was the only one observed during nearly 3 weeks of operations. This low frequency-of-occurrence is attributed partly to high local noise levels. The ease with which this event was identified on the ionograms produced by the local ionosonde suggests that routine ionosonde recordings should be inspected in search for such events. Such an effort would enhance existing research directed toward developing techniques for identifying quiet communication channels and help to identify the origin and frequency-of-occurrence of high-latitude wideband noise events. 20 refs.

Benson, R.F.; Desch, M.D. (NASA, Goddard Space Flight Center, Greenbelt, MD (United States))

1991-08-01T23:59:59.000Z

273

Above Ground Storage Tank (AST) Inspection Form  

E-Print Network [OSTI]

Above Ground Storage Tank (AST) Inspection Form Petroleum Bulk Storage Form Facility Name: ______________________ Tank No:_______________ Date:_____________ Inspection Parameter Result Comments/Corrective Actions 1. Is there leaking in the interstitial space (not DRY)? YES/NO/NA 2. Tank surface shows signs of leakage? YES/NO/NA 3

Pawlowski, Wojtek

274

Recent Ground Motion Studies at SLAC  

SciTech Connect (OSTI)

Studies of slow ground motion have recently been performed at SLAC using the linac laser alignment system over a period of one month. Two significant effects responsible for the observed motion have been identified, namely tidal forces and variation of external atmospheric pressure. The latter is of particular interest as it may result in misalignments with rather short wavelength.

Seryi, Andrei

2000-06-28T23:59:59.000Z

275

Ground Vibration Measurements at LHC Point 4  

SciTech Connect (OSTI)

Ground vibration was measured at Large Hadron Collider (LHC) Point 4 during the winter shutdown in February 2012. This report contains the results, including power and coherence spectra. We plan to collect and analyze vibration data from representative collider halls to inform specifications for future linear colliders, such as ILC and CLIC. We are especially interested in vibration correlations between final focus lens locations.

Bertsche, Kirk; /SLAC; Gaddi, Andrea; /CERN

2012-09-17T23:59:59.000Z

276

CONFERENCE -CALL FOR PAPERS & PRESENTATIONS Mainstreaming Co-operation: An Alternative for the 21st  

E-Print Network [OSTI]

-operatives have also been important in promoting ethical and equitable development in some of the poorest parts would a renewed vision of co-operation for the 21st century, grounded in the creativity, energy and interested in co-operative practice, organisation, ideals, ethics and philosophy. We welcome the experiences

277

Extremal covariant quantum operations and POVM's  

E-Print Network [OSTI]

We consider the convex sets of QO's (quantum operations) and POVM's (positive operator valued measures) which are covariant under a general finite-dimensional unitary representation of a group. We derive necessary and sufficient conditions for extremality, and give general bounds for ranks of the extremal POVM's and QO's. Results are illustrated on the basis of simple examples.

Giacomo Mauro D'Ariano

2003-10-03T23:59:59.000Z

278

DOE/EA-1388: Environmental Assessment of Ground Water Compliance at the Shiprock Uranium Mill Tailings Site (September 2001)  

Broader source: Energy.gov (indexed) [DOE]

388 388 Environmental Assessment of Ground Water Compliance at the Shiprock Uranium Mill Tailings Site Final September 2001 Prepared by U.S. Department of Energy Grand Junction Office Grand Junction, Colorado Work Performed Under DOE Contract No. DE-AC13-96GJ87335 This Page Intentionally Blank DOE Grand Junction Office EA of Ground Water Compliance at the Shiprock Site September 2001 Final Page iii Contents Page Acronyms and Abbreviations ........................................................................................................ vii Executive Summary ....................................................................................................................... ix 1.0 Introduction .............................................................................................................................1

279

Reservoir Operation in Texas  

E-Print Network [OSTI]

Effective management of its surface water resources is essential to the continued growth and prosperity of the state of Texas. Rapid population and economic growth combined with depleting ground water reserves are resulting in ever increasing...

Wurbs, Ralph A.

280

CLEANING UP MILL TAILINGS AND GROUND WATER AT THE MOAB UMTRA PROJECT SITE |  

Broader source: Energy.gov (indexed) [DOE]

CLEANING UP MILL TAILINGS AND GROUND WATER AT THE MOAB UMTRA CLEANING UP MILL TAILINGS AND GROUND WATER AT THE MOAB UMTRA PROJECT SITE CLEANING UP MILL TAILINGS AND GROUND WATER AT THE MOAB UMTRA PROJECT SITE August 2, 2010 - 12:00pm Addthis A sheep’s foot roller compacts the tailings in the disposal cell. A sheep's foot roller compacts the tailings in the disposal cell. Moab, UT MILL TAILINGS REMOVAL Sixteen million tons of uranium mill tailings 80 feet high stood on the banks of the Colorado River near Moab in southeast Utah, as a legacy to the former ore-processing site that operated for nearly three decades beginning in the mid-1950s. That is until April 2009, when the U.S. Department of Energy began moving the tailings by rail to an engineered disposal cell constructed 30 miles north near Crescent Junction, Utah. The mill tailings,

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

The Surveillance And Reconnaissance Ground Equipment (SARGE), real robots for real soldiers  

SciTech Connect (OSTI)

The Joint Program Office for Unmanned Ground Vehicles and Sandia National Laboratories are developing the Surveillance And Reconnaissance Ground Equipment (SARGE) robot. The SARGE system is a second generation refinement of Sandia`s Dixie robot. A comparison of Dixie`s actual performance and the expected SARGE performance characteristics will be given. The SARGE design philosophy embraces proven technology, low power consumption, and modular sensor packages designed to meet specific mission needs. A major aspect of the SARGE program is obtaining user acceptance through ownership of the prototype hardware. A total of ten systems are being fabricated with at least eight being given to infantry battalions for their use in day to day operations. The SARGE robot is a prototype system that is not intended to meet all the needs of the infantry soldier but will provide a reliable platform which will enable the soldier to determine first hand the required capabilities for future unmanned ground vehicles on the battlefield.

Pletta, J.B.

1994-04-01T23:59:59.000Z

282

Ground-state cooling of a trapped ion using long-wavelength radiation  

E-Print Network [OSTI]

We demonstrate ground-state cooling of a trapped ion using long-wavelength radiation. This is a powerful tool for the implementation of quantum operations, where long-wavelength radiation instead of lasers is used for motional quantum state engineering. We measure a mean phonon number of $\\overline{n} = 0.13(4)$ after sideband cooling, corresponding to a ground-state occupation probability of 88(7)\\%. After preparing in the vibrational Fock state $\\left|n=0\\right\\rangle$, we implement sideband Rabi oscillations which last for more than 10 ms, demonstrating the long coherence time of our system. We also use the ability to ground-state cool to accurately measure the motional heating rate and report a reduction by almost two orders of magnitude compared to our previously measured result, which we attribute to carefully eliminating sources of electrical noise in the system.

Weidt, S; Webster, S C; Standing, E D; Rodriguez, A; Webb, A E; Lekitsch, B; Hensinger, W K

2015-01-01T23:59:59.000Z

283

Ground-state cooling of a trapped ion using long-wavelength radiation  

E-Print Network [OSTI]

We demonstrate ground-state cooling of a trapped ion using long-wavelength radiation. This is a powerful tool for the implementation of quantum operations, where long-wavelength radiation instead of lasers is used for motional quantum state engineering. We measure a mean phonon number of $\\overline{n} = 0.13(4)$ after sideband cooling, corresponding to a ground-state occupation probability of 88(7)\\%. After preparing in the vibrational Fock state $\\left|n=0\\right\\rangle$, we implement sideband Rabi oscillations which last for more than 10 ms, demonstrating the long coherence time of our system. We also use the ability to ground-state cool to accurately measure the motional heating rate and report a reduction by almost two orders of magnitude compared to our previously measured result, which we attribute to carefully eliminating sources of electrical noise in the system.

S. Weidt; J. Randall; S. C. Webster; E. D. Standing; A. Rodriguez; A. E. Webb; B. Lekitsch; W. K. Hensinger

2015-01-07T23:59:59.000Z

284

GRR/Section 14-TX-e - Ground Water Discharge Permit | Open Energy  

Open Energy Info (EERE)

GRR/Section 14-TX-e - Ground Water Discharge Permit GRR/Section 14-TX-e - Ground Water Discharge Permit < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 14-TX-e - Ground Water Discharge Permit 14TXEGroundWaterDischargePermit (1).pdf Click to View Fullscreen Contact Agencies Railroad Commission of Texas United States Environmental Protection Agency Regulations & Policies 16 TAC 3.8 (Rule 8) Triggers None specified Click "Edit With Form" above to add content 14TXEGroundWaterDischargePermit (1).pdf 14TXEGroundWaterDischargePermit (1).pdf Error creating thumbnail: Page number not in range. Error creating thumbnail: Page number not in range. Flowchart Narrative Pits are used in drilling operations to contain drilling related fluids and

285

Ground-water sample collection and analysis plan for the ground-water surveillance project  

SciTech Connect (OSTI)

The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy`s (DOE`s) Hanford Site in support of DOE`s environmental surveillance responsibilities. The purpose of this document is to translate DOE`s General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives.

Bryce, R.W.; Evans, J.C.; Olsen, K.B.

1991-12-01T23:59:59.000Z

286

Ground-water sample collection and analysis plan for the ground-water surveillance project  

SciTech Connect (OSTI)

The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy's (DOE's) Hanford Site in support of DOE's environmental surveillance responsibilities. The purpose of this document is to translate DOE's General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives.

Bryce, R.W.; Evans, J.C.; Olsen, K.B.

1991-12-01T23:59:59.000Z

287

Optical Particle Counter Operating Procedures, Calibration and Correlation Methods  

Science Journals Connector (OSTI)

Data from any OPC are derived on the basis of a number of OPC design and operating parameters. Most operators assume that the data produced are valid for any material and under any circumstances. However, it must...

Alvin Lieberman

1992-01-01T23:59:59.000Z

288

JLF Conduct of Operations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Jupiter Laser Facility (JLF) Conduct Of Operations The Conduct of Operations is a set of procedures and guidelines that are put in place to ensure operational safety and security...

289

Heat Transfer Operators Associated with Quantum Operations  

E-Print Network [OSTI]

Any quantum operation applied on a physical system is performed as a unitary transformation on a larger extended system. If the extension used is a heat bath in thermal equilibrium, the concomitant change in the state of the bath necessarily implies a heat exchange with it. The dependence of the average heat transferred to the bath on the initial state of the system can then be found from the expectation value of a hermitian operator, which is named as the heat transfer operator (HTO). The purpose of this article is the investigation of the relation between the HTOs and the associated quantum operations. Since, any given quantum operation on a system can be realized by different baths and unitaries, many different HTOs are possible for each quantum operation. On the other hand, there are also strong restrictions on the HTOs which arise from the unitarity of the transformations. The most important of these is the Landauer erasure principle. This article is concerned with the question of finding a complete set of restrictions on the HTOs that are associated with a given quantum operation. An answer to this question has been found only for a subset of quantum operations. For erasure operations, these characterizations are equivalent to the generalized Landauer erasure principle. For the case of generic quantum operations however, it appears that the HTOs obey further restrictions which cannot be obtained from the entropic restrictions of the generalized Landauer erasure principle.

Ç. Aksak; S. Turgut

2011-04-14T23:59:59.000Z

290

DOE-Idaho Operations Summary For May 17 to June 6, 2011  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Idaho Cleanup Project May 19: Liquid nitrogen from tank venting flowed under the work boots of an operator at the Integrated Waste Treatment Unit site, freezing the operator's...

291

Ground-State Structures of Ice at High-Pressures  

E-Print Network [OSTI]

\\textit{Ab initio} random structure searching based on density functional theory is used to determine the ground-state structures of ice at high pressures. Including estimates of lattice zero-point energies, ice is found to adopt three novel crystal phases. The underlying sub-lattice of O atoms remains similar among them, and the transitions can be characterized by reorganizations of the hydrogen bonds. The symmetric hydrogen bonds of ice X and $Pbcm$ are initially lost as ice transforms to structures with symmetries $Pmc2_1$ (800 - 950 GPa) and $P2_1$ (1.17 TPa), but they are eventually regained at 5.62 TPa in a layered structure $C2/m$. The $P2_1 \\rightarrow C2/m$ transformation also marks the insulator-to-metal transition in ice, which occurs at a significantly higher pressure than recently predicted.

McMahon, Jeffrey M

2011-01-01T23:59:59.000Z

292

Office of Headquarters Security Operations  

Broader source: Energy.gov [DOE]

The Office of Headquarters Security Operations strengthens national security by protecting personnel, facilities, property, classified information, and sensitive unclassified information for DOE Headquarters facilities in the National Capital Area under normal and abnormal (i.e., emergency) conditions; managing access authorization functions for Headquarters; ensuring that executives and dignitaries are fully protected, and supporting efforts to ensure the continuity of government in all circumstances as mandated by Presidential Decision Directive.

293

Uncertainty propagation in a model for the estimation of the1 ground level concentration of dioxin/furans emitted from a waste2  

E-Print Network [OSTI]

Uncertainty propagation in a model for the estimation of the1 ground level concentration of dioxin concentration of dioxin/furans emitted from a waste gasification plant. Under the17 condition of insufficient

Paris-Sud XI, Université de

294

System for detecting and limiting electrical ground faults within electrical devices  

DOE Patents [OSTI]

An electrical ground fault detection and limitation system for employment with a nuclear reactor utilizing a liquid metal coolant. Elongate electromagnetic pumps submerged within the liquid metal coolant and electrical support equipment experiencing an insulation breakdown occasion the development of electrical ground fault current. Without some form of detection and control, these currents may build to damaging power levels to expose the pump drive components to liquid metal coolant such as sodium with resultant undesirable secondary effects. Such electrical ground fault currents are detected and controlled through the employment of an isolated power input to the pumps and with the use of a ground fault control conductor providing a direct return path from the affected components to the power source. By incorporating a resistance arrangement with the ground fault control conductor, the amount of fault current permitted to flow may be regulated to the extent that the reactor may remain in operation until maintenance may be performed, notwithstanding the existence of the fault. Monitors such as synchronous demodulators may be employed to identify and evaluate fault currents for each phase of a polyphase power, and control input to the submerged pump and associated support equipment.

Gaubatz, Donald C. (Cupertino, CA)

1990-01-01T23:59:59.000Z

295

40 CFR 265 interim-status ground-water monitoring plan for the 2101-M pond  

SciTech Connect (OSTI)

This report outlines a ground-water monitoring plan for the 2101-M pond, located in the southwestern part of the 200-East Area on the Hanford Site in south-central Washington State. It has been determined that hazardous materials may have been discharged to the pond. Installation of an interim-status ground-water monitoring system is required under the Resource Conservation and Recovery Act to determine if hazardous chemicals are moving out of the pond. This plan describes the location of new wells for the monitoring system, how the wells are to be completed, the data to be collected, and how those data can be used to determine the source and extent of any ground-water contamination from the 2101-M pond. Four new wells are planned, one upgradient and three downgradient. 35 refs., 12 figs., 9 tabs.

Chamness, M.A.; Luttrell, S.P.; Dudziak, S.

1989-03-01T23:59:59.000Z

296

Remedial investigation/feasibility study work plan for the 100-BC-2 operable unit, Hanford Site, Richland, Washington  

SciTech Connect (OSTI)

This work plan and attached supporting project plans establish the operable unit setting and the objectives, procedures, tasks, and schedule for conducting the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) remedial investigation/feasibility study (RI/FS) for the 100-BC-2 operable unit in the 100 Area of the Hanford Site. The 100 Area is one of four areas at the Hanford Site that are on the US Environmental Protection Agency`s (EPA) National Priorities List under CERCLA. The 100-BC-2 operable unit is one of two source operable units in the 100-B/C Area (Figure ES-1). Source operable units are those that contain facilities and unplanned release sites that are potential sources of hazardous substance contamination. The 100-BC-2 source operable unit contains waste sites that were formerly in the 100-BC-2, 100-BC-3, and 100-BC-4 operable units. Because of their size and geographic location, the waste sites from these two operable units were added to 100-BC-2. This allows for a more efficient and effective investigation of the remaining 100-B/C Reactor area waste sites. The investigative approach to waste sites associated with the 100-BC-2 operable unit are listed in Table ES-1. The waste sites fall into three general categories: high priority liquid waste disposal sites, low priority liquid waste disposal sites, and solid waste burial grounds. Several sites have been identified as candidates for conducting an IRM. Two sites have been identified as warranting additional limited field sampling. The two sites are the 116-C-2A pluto crib, and the 116-C-2C sand filter.

Not Available

1993-05-01T23:59:59.000Z

297

Optimization of solar assisted ground source heat pump system for space heating application by Taguchi method and utility concept  

Science Journals Connector (OSTI)

Abstract In the present research, a methodology is proposed to optimize the solar collector area and ground heat exchanger length for achieving higher COP of Solar Assisted Ground Source Heat Pump (SAGSHP) system using Taguchi method and utility concept. Four operating parameters for solar collector and four parameters for ground heat exchanger have been selected with mixed level variation using an L18 (21, 37) orthogonal array. The key parameters such as solar collector area, ground heat exchanger length and COP of the SAGSHP system are optimized to predict the best levels of operating parameters for maximum COP of SAGSHP system. Lower the better concept has been used for the solar collector area and ground heat exchanger length whereas higher the better concept has been employed for the COP of SAGSHP system and the results have been analyzed for the optimum conditions using signal-to-noise (SN) ratio and ANOVA method. Computations were carried out for 18 experimental trial runs by considering 2 ton heating load in winter season. The optimum COP for SAGSHP was estimated to be 4.23 from the utility concept, which is 8.74% higher than the optimum COP predicted by Taguchi optimization. Optimization of solar collector area and ground heat exchanger length by the utility concept has shown only about 2.3% reduction in area and 1.6% reduction in length respectively compared to those values optimized by the Taguchi method.

Vikas Verma; K. Murugesan

2014-01-01T23:59:59.000Z

298

Definition: Operating Reserve | Open Energy Information  

Open Energy Info (EERE)

Operating Reserve Operating Reserve Jump to: navigation, search Dictionary.png Operating Reserve That capability above firm system demand required to provide for regulation, load forecasting error, equipment forced and scheduled outages and local area protection. It consists of spinning and non-spinning reserve.[1] View on Wikipedia Wikipedia Definition In electricity networks, the operating reserve is the generating capacity available to the system operator within a short interval of time to meet demand in case a generator goes down or there is another disruption to the supply. Most power systems are designed so that, under normal conditions, the operating reserve is always at least the capacity of the largest generator plus a fraction of the peak load. The operating reserve

299

Electricity market clearing price forecasting under a deregulated electricity market.  

E-Print Network [OSTI]

??Under deregulated electric market, electricity price is no longer set by the monopoly utility company rather it responds to the market and operating conditions. Offering… (more)

Yan, Xing

2010-01-01T23:59:59.000Z

300

Ground-Source Heat Pumps Applied to Federal Facilities, Second Edition  

Broader source: Energy.gov (indexed) [DOE]

and exterior to the facility, are typically less and exterior to the facility, are typically less than those for conventional systems. Potential Application The technology has been shown to be techni- cally valid and economically attractive in many applications. It is efficient and effective. This Federal Technology Alert reports on the collec- tive experience of heat pump users and evalua- tors and provides application guidance. An estimated 400,000 ground-source heat pumps are operating in the private and public sector, although most of these systems operate in resi- dential applications. A ground-source heat pump system can be applied in virtually any category of climate or building. The large num- ber of installations testifies to the stability of this technology. The reported problems can usually be attributed to faulty design or

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Ground-Source Heat Pumps Applied to Federal Facilities, Second Edition  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

E E N E R G Y M A N A G E M E N T P R O G R A M and exterior to the facility, are typically less than those for conventional systems. Potential Application The technology has been shown to be techni- cally valid and economically attractive in many applications. It is efficient and effective. This Federal Technology Alert reports on the collec- tive experience of heat pump users and evalua- tors and provides application guidance. An estimated 400,000 ground-source heat pumps are operating in the private and public sector, although most of these systems operate in resi- dential applications. A ground-source heat pump system can be applied in virtually any category of climate or building. The large num- ber of installations testifies to the stability of this technology. The reported problems can

302

Texas Tech University GROUNDS USE / SOLICITATION REQUEST  

E-Print Network [OSTI]

be Coke products Plywood under grill Bring trash bags Dispose of coals off-campus Have water turned off

Rock, Chris

303

Ground Source Heat Pump System Data Analysis  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Peer Review Peer Review GSHP System Data Analysis Xiaobing Liu, Ph.D. Oak Ridge National Laboratory liux2@ornl.gov (865-574-2593) 4/3/2013 - GSHP Data Analysis in 1 st phase of U.S.-China CERC-BEE - GSHP ARRA Grantee Data Mining 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: High first cost of ground heat exchangers (GHXs) and lack of knowledge/trust in achievable benefits are major barriers preventing

304

Ground Source Heat Pump System Data Analysis  

Broader source: Energy.gov (indexed) [DOE]

Peer Review Peer Review GSHP System Data Analysis Xiaobing Liu, Ph.D. Oak Ridge National Laboratory liux2@ornl.gov (865-574-2593) 4/3/2013 - GSHP Data Analysis in 1 st phase of U.S.-China CERC-BEE - GSHP ARRA Grantee Data Mining 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: High first cost of ground heat exchangers (GHXs) and lack of knowledge/trust in achievable benefits are major barriers preventing

305

Sprites, elf transients, and positive ground strokes  

SciTech Connect (OSTI)

In two summertime mesoscale convective systems (MCSs), mesospheric optical sprite phenomena were often coincident with both large-amplitude positive cloud-to-ground lightning and transient Schumann resonance excitations of the entire Earth-ionosphere cavity. These observations, together with earlier studies of MCS electrification, suggest that sprites are triggered when the rapid removal of large quantities of positive charge from an areally extensive charge layer stresses the mesosphere to dielectric breakdown. 46 refs., 7 figs., 1 tab.

Boccippio, D.J.; Boldi, R.; Williams, E.R. [Massachusetts Inst. of Technology, Cambridge, MA (United States)] [and others

1995-08-25T23:59:59.000Z

306

External breaking of ground-state symmetry  

Science Journals Connector (OSTI)

Ground-state symmetry can be broken by an external field. The threshold value of the symmetry-breaking field may be roughly estimated by comparing experimentally the behavior of two identical physical quantities, as functions of the field, for the set of field directions equivalent, with respect to the action, to a group generator. The kinetic coefficients as the functions of magnetic induction B are used as an illustration.

S. Malinowski

1994-01-01T23:59:59.000Z

307

R/Blkstripe CTB Ground Strap  

E-Print Network [OSTI]

5 5 4 4 3 3 2 2 1 1 D D C C B B A A Orange Black Yellow Blue R/Blkstripe Tan Red CTB Ground Strap Title Size Document Number R ev Date: Sheet o f ? ToFr 2003_S Run 4 L.V Setup Rice. U. Bonner Lab B 1 1, Limited (picoFuse) @ 3.0 A 7x"VNTC"#14awgrated17A Actualoperating=7.7Amax. LOW VOLTAGE SUPPLY SETTINGS

Llope, William J.

308

Mission Operations & Data Systems  

E-Print Network [OSTI]

Mission Operations & Data Systems The LASP Mission Operations & Data Systems (MO&DS) group staffs and instruments. Operational software acts like the health systems in a body, ensuring that temperature, energy. The software monitors the health of on-board systems; anything unusual is flagged and sent to mission operators

Mojzsis, Stephen J.

309

ARM - SGP Operations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Operations Operations SGP Related Links Facilities and Instruments Central Facility Boundary Facility Extended Facility Intermediate Facility Radiometric Calibration Facility Geographic Information ES&H Guidance Statement Operations Science Field Campaigns Visiting the Site Fact Sheet Images Information for Guest Scientists Contacts SGP Operations Routine Operations SGP central facility offices. SGP central facility offices. The overwhelming majority of the measurements with the highest priority, on which the existing experimental designs are based, are regular routine observations, as specified in the ARM Program Plan, 1990 (U.S. Department of Energy 1990). Scientifically and logistically, routine operations also serve as the basis and background for all nonroutine operations, including

310

Definition: Operating Voltage | Open Energy Information  

Open Energy Info (EERE)

Voltage Voltage Jump to: navigation, search Dictionary.png Operating Voltage The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related; also, the effective (root-mean-square) potential difference between any two conductors or between a conductor and the ground. The actual voltage of the circuit may vary somewhat above or below this value.[1] Related Terms system References ↑ Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Operating_Voltage&oldid=480559" Categories: Definitions ISGAN Definitions What links here Related changes

311

Hydraulic pump with in-ground filtration and monitoring capability  

DOE Patents [OSTI]

A hydraulically operated pump is described for in-ground filtering and monitoring of wells or other fluid sources, including a hollow cylindrical pump housing with an inlet and an outlet, filtering devices positioned in the inlet and the outlet, a piston that fits slidably within the pump housing, and an optical cell in fluid communication with the pump housing. A conduit within the piston allows fluid communication between the exterior and one end of the piston. A pair of O-rings form a seal between the inside of the pump housing and the exterior of the piston. A flow valve positioned within the piston inside the conduit allows fluid to flow in a single direction. In operation, fluid enters the pump housing through the inlet, flows through the conduit and towards an end of the pump housing. The piston then makes a downward stroke closing the valve, thus forcing the fluid out from the pump housing into the optical cell, which then takes spectrophotometric measurements of the fluid. A spring helps return the piston back to its starting position, so that a new supply of fluid may enter the pump housing and the downward stroke can begin again. The pump may be used independently of the optical cell, as a sample pump to transport a sample fluid from a source to a container for later analysis.

Hopkins, C.D.; Livingston, R.R.; Toole, W.R. Jr.

1995-01-01T23:59:59.000Z

312

Hanford facility dangerous waste permit application, low-level burial grounds  

SciTech Connect (OSTI)

The Hanford Facility Dangerous Plaste Permit Application is considered to be a single application organized into a General Information Portion (document number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion is limited to Part B permit application documentation submitted for individual, `operating` treatment, storage, and/or disposal units, such as the Low-Level Burial Grounds (this document, DOE/RL-88-20).

Engelmann, R.H.

1997-08-12T23:59:59.000Z

313

Engineering assessment of low-level liquid waste disposal caisson locations at the 618-11 Burial Grounds  

SciTech Connect (OSTI)

Rockwell Hanford Operations is currently involved in an extensive effort to perform interim ground surface stabilization activities at retired low-level waste burial grounds located at the Hanford Site, Richland, Washington. The principal objective of these activities is to promote increased occupational and radiological safety at burial grounds. Interim stabilization activities include: (1) load testing (traversing burial ground surfaces with heavy equipment to promote incipient collapse of void spaces within the disposal structure and overburden), (2) barrier placement (placement of a {ge} 0.6 m soil barrier over existing overburden), and (3) revegetation (establishment of shallow rooted vegetation on the barrier to mitigate deep rooted plant growth and to reduce erosion). Low-level waste disposal caissons were used in 300 Area Burial Grounds as internment structures for containerized liquid wastes. These caissons, by virtue of their contents, design and methods of closure, require long-term performance evaluation. As an initial activity to evaluate long-term performance, the accurate location of these structures is required. This topical report summarizes engineering activities used to locate caissons in the subsurface environment at the Burial Ground. Activities were conducted to locate caissons during surface stabilization activities. The surface locations were marked, photographed, and recorded on an as built engineering drawing. The recorded location of these caissons will augment long-term observations of confinement structure and engineered surface barrier performance. In addition, accurate caisson location will minimize occupational risk during monitoring and observation activities periodically conducted at the burial ground.

Phillips, S.J.; Fischer, D.D.; Crawford, R.C. [Westinghouse Hanford Co., Richland, WA (United States); Rising, J.L. [Pacific Northwest Lab., Richland, WA (United States)

1982-06-01T23:59:59.000Z

314

Application of decision tree model for the ground subsidence hazard mapping near abandoned underground coal mines  

Science Journals Connector (OSTI)

Abstract Subsidence of ground caused by underground mines poses hazards to human life and property. This study analyzed the hazard to ground subsidence using factors that can affect ground subsidence and a decision tree approach in a geographic information system (GIS). The study area was Taebaek, Gangwon-do, Korea, where many abandoned underground coal mines exist. Spatial data, topography, geology, and various ground-engineering data for the subsidence area were collected and compiled in a database for mapping ground-subsidence hazard (GSH). The subsidence area was randomly split 50/50 for training and validation of the models. A data-mining classification technique was applied to the GSH mapping, and decision trees were constructed using the chi-squared automatic interaction detector (CHAID) and the quick, unbiased, and efficient statistical tree (QUEST) algorithms. The frequency ratio model was also applied to the GSH mapping for comparing with probabilistic model. The resulting GSH maps were validated using area-under-the-curve (AUC) analysis with the subsidence area data that had not been used for training the model. The highest accuracy was achieved by the decision tree model using CHAID algorithm (94.01%) comparing with QUEST algorithms (90.37%) and frequency ratio model (86.70%). These accuracies are higher than previously reported results for decision tree. Decision tree methods can therefore be used efficiently for GSH analysis and might be widely used for prediction of various spatial events.

Saro Lee; Inhye Park

2013-01-01T23:59:59.000Z

315

Air–ground interaction effects in the propagation of low?frequency impulse noise  

Science Journals Connector (OSTI)

Four large?scale sound propagation experiments performed in Norway from 1994 to 1996 under both summer and winter conditions clearly demonstrate that air–ground interaction has a significant effect on the propagation of low?frequency impulse noise. During the experiments specific measurements were made for detailed investigation of this interaction. The paper will present the instrumentation used and some typical measured data. Various numerical simulations of the experiments are made covering both poro?elastic and visco?elastic description of the ground. Based on the measured data theoretical considerations and the numerical simulations the paper will discuss mechanisms for acoustic energy loss from the air into the ground. Special emphasis will be put on the effect of the interaction of the propagating air pressure with the slow p?waves and with the dispersive Rayleigh waves in the ground. The relative importance of these two interaction mechanisms on the energy loss and thus on the sound attenuation will be examined for various ground conditions.

Christian Madshus; Amir M. Kaynia; Lars R. Hole

1999-01-01T23:59:59.000Z

316

Ground states and dynamics of spin-orbit-coupled Bose-Einstein condensates  

E-Print Network [OSTI]

We study analytically and asymptotically as well as numerically ground states and dynamics of two-component spin-orbit-coupled Bose-Einstein condensates (BECs) modeled by the coupled Gross-Pitaevskii equations (CGPEs). In fact, due to the appearance of the spin-orbit (SO) coupling in the two-component BEC with a Raman coupling, the ground state structures and dynamical properties become very rich and complicated. For the ground states, we establish the existence and non-existence results under different parameter regimes, and obtain their limiting behaviors and/or structures with different combinations of the SO and Raman coupling strengths. For the dynamics, we show that the motion of the center-of-mass is either non-periodic or with different frequency to the trapping frequency when the external trapping potential is taken as harmonic and the initial data is chosen as a stationary state (e.g. ground state) with a shift, which is completely different from the case of a two-component BEC without the SO coupling, and obtain the semiclassical limit of the CGPEs in the linear case via the Wigner transform method. Efficient and accurate numerical methods are proposed for computing the ground states and dynamics, especially for the case of box potentials. Numerical results are reported to demonstrate the efficiency and accuracy of the numerical methods and show the rich phenomenon in the SO-coupled BECs.

Weizhu Bao; Yongyong Cai

2014-07-22T23:59:59.000Z

317

Baseline risk assessment of ground water contamination at the Monument Valley uranium mill tailings site Cane Valley, Arizona  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project consists of the Surface Project (Phase I) and the Ground Water Project (Phase II). Under the UMTRA Surface Project, tailings, radioactive contaminated soil, equipment, and materials associated with the former uranium ore processing at UMTRA Project sites are placed into disposal cells. The cells are designed to reduce radon and other radiation emissions and to minimize further contamination of ground water. Surface cleanup at the Monument Valley UMTRA Project site near Cane Valley, Arizona, was completed in 1994. The Ground Water Project evaluates the nature and extent of ground water contamination that resulted from the uranium ore processing activities. The Ground Water Project is in its beginning stages. Human health may be at risk from exposure to ground water contaminated by uranium ore processing. Exposure could occur by drinking water pumped out of a hypothetical well drilled in the contaminated areas. Adverse ecological and agricultural effects may also result from exposure to contaminated ground water. For example, livestock should not be watered with contaminated ground water. A risk assessment describes a source of contamination, how that contamination reaches people and the environment, the amount of contamination to which people or the ecological environment may be exposed, and the health or ecological effects that could result from that exposure. This risk assessment is a site-specific document that will be used to evaluate current and potential future impacts to the public and the environment from exposure to contaminated ground water. The results of this evaluation and further site investigations will be used to determine a compliance strategy to comply with the UMTRA ground water standards.

NONE

1996-03-01T23:59:59.000Z

318

Headquarters Security Operations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Headquarters Security Operations Headquarters Security Operations Headquarters Security Operations Mission The Office of Headquarters Security Operations strengthens national security by protecting personnel, facilities, property, classified information, and sensitive unclassified information for DOE Headquarters facilities in the National Capital Area under normal and abnormal (i.e., emergency) conditions; managing access authorization functions; ensuring that executives and dignitaries are fully protected, and supporting efforts to ensure the continuity of government in all circumstances as mandated by Presidential Decision Directive. The Office is the database owner for the principal personnel security information processing activities of the Department and personnel security administrative review process.

319

Federal Energy Management Program: Covered Product Category: Ground-Source  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ground-Source Heat Pumps to someone by E-mail Ground-Source Heat Pumps to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Ground-Source Heat Pumps on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Ground-Source Heat Pumps on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Ground-Source Heat Pumps on Google Bookmark Federal Energy Management Program: Covered Product Category: Ground-Source Heat Pumps on Delicious Rank Federal Energy Management Program: Covered Product Category: Ground-Source Heat Pumps on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Ground-Source Heat Pumps on AddThis.com... Energy-Efficient Products Federal Requirements Covered Product Categories

320

New and Underutilized Technology: Commercial Ground Source Heat Pumps |  

Broader source: Energy.gov (indexed) [DOE]

Commercial Ground Source Heat Commercial Ground Source Heat Pumps New and Underutilized Technology: Commercial Ground Source Heat Pumps October 8, 2013 - 2:59pm Addthis The following information outlines key deployment considerations for commercial ground source heat pumps within the Federal sector. Benefits Commercial ground source heat pumps are ground source heat pump with loops that feed multiple packaged heat pumps and a single ground source water loop. Unit capacity is typically 1-10 tons and may be utilized in an array of multiple units to serve a large load. Application Condensing boilers are appropriate for housing, service, office, and research and development applications. Key Factors for Deployment FEMP has made great progress with commercial ground source heat pump technology deployment within the Federal sector. Primary barriers deal with

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Category:Ground Electromagnetic Techniques | Open Energy Information  

Open Energy Info (EERE)

Ground Electromagnetic Techniques Ground Electromagnetic Techniques Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Geothermalpower.jpg Looking for the Ground Electromagnetic Techniques page? For detailed information on Ground Electromagnetic Techniques, click here. Category:Ground Electromagnetic Techniques Add.png Add a new Ground Electromagnetic Techniques Technique Subcategories This category has the following 2 subcategories, out of 2 total. E [×] Electromagnetic Profiling Techniques‎ 1 pages [+] Electromagnetic Sounding Techniques‎ (1 categories) 2 pages Pages in category "Ground Electromagnetic Techniques" The following 2 pages are in this category, out of 2 total. E Electromagnetic Profiling Techniques Electromagnetic Sounding Techniques Retrieved from "http://en.openei.org/w/index.php?title=Category:Ground_Electromagnetic_Techniques&oldid=689834"

322

The Design of Ground-Coupled Heat Pump Systems  

E-Print Network [OSTI]

Ground-coupled heat pumps are being installed in increasing numbers due to proven performance and economy. The overall thermal resistance between the ground coupling fluid and a given type of surrounding soil is affected by pipe material, wall...

Parker, J. D.

1985-01-01T23:59:59.000Z

323

Analysis of Contaminant Rebound in Ground Water in Extraction...  

Office of Environmental Management (EM)

Analysis of Contaminant Rebound in Ground Water in Extraction Wells at the Tuba City, Arizona, Site Analysis of Contaminant Rebound in Ground Water in Extraction Wells at the Tuba...

324

Diffusion Multilayer Sampling of Ground Water in Five Wells at...  

Office of Environmental Management (EM)

Diffusion Multilayer Sampling of Ground Water in Five Wells at the Tuba City, Arizona, Site Diffusion Multilayer Sampling of Ground Water in Five Wells at the Tuba City, Arizona,...

325

Response of continuous pipelines to tunnel induced ground deformations  

E-Print Network [OSTI]

This thesis develops analytical solutions for estimating the bending moments and axial loads in a buried pipeline due to ground movements caused by tunnel construction in soft ground. The solutions combine closed-form, ...

Ieronymaki, Evangelia S

2011-01-01T23:59:59.000Z

326

165 F ... Poultry, ground poultry Stuffing with poultry, meat & fish  

E-Print Network [OSTI]

165° F ... Poultry, ground poultry Stuffing with poultry, meat & fish Microwave cooking & reheating Reheating leftovers 155° F ... Ground meat & fish Injected meat (i.e. tenderized) 145° F ... Meat, fish

327

Building Technologies Office: Ground Source Heap Pump Data Mining Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ground Source Heap Pump Ground Source Heap Pump Data Mining Research Project to someone by E-mail Share Building Technologies Office: Ground Source Heap Pump Data Mining Research Project on Facebook Tweet about Building Technologies Office: Ground Source Heap Pump Data Mining Research Project on Twitter Bookmark Building Technologies Office: Ground Source Heap Pump Data Mining Research Project on Google Bookmark Building Technologies Office: Ground Source Heap Pump Data Mining Research Project on Delicious Rank Building Technologies Office: Ground Source Heap Pump Data Mining Research Project on Digg Find More places to share Building Technologies Office: Ground Source Heap Pump Data Mining Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities

328

ATM 10561 B GROUND OPERATIONS AND SAFETY PLAN j_:P~A~G:_E==l=_  

E-Print Network [OSTI]

::'~~-I & C 1 s 4. 11 Assembly of Live EP's 4. 12 A,, sembly of Handling Model EPTM 4. 13 W tlk Thru of EPTM Explosivf Devices and Inert Equivalents 5. 2 Functional Diagram of E&SA and Interfacing Test Set,. 6. 0 of the Bendix Corporation, Aerospace Systems Division (BxA). E'ufficient background material has been included

Rathbun, Julie A.

329

Background: Most seismometers detect ground motion using a mass that is suspended in some fashion by a spring. When the ground moves the seismometer's frame also moves. The mass  

E-Print Network [OSTI]

by a spring. When the ground moves the seismometer's frame also moves. The mass tends to remain relatively, a galvanometer, or a magnet and coil assembly. Seismometers are usually sensitive to one component (direction the seismic signals. The magnet and coil sensor (the type we will be building) operates by measuring

Smith-Konter, Bridget

330

Appendix E Supporting Information for Ground Water Modeling  

Office of Legacy Management (LM)

Supporting Information for Ground Water Modeling Supporting Information for Ground Water Modeling This page intentionally left blank Contents Section Geologic Map of Site Area ........................................................................................................ E1.O Stream Flow Measurements ...................................................................................................... E2.0 Estimates of Ground Water Flow .............................................................................................. E3.0 .......................................... MODFLOW Flow Budget Analysis for OU 1 1 1 Model Subregions E4.0 ............................................................................ Burro Canyon Aquifer Ground Water Model E5.0 This page intentionally left blank

331

Recommendation 195: Mitigation of Contamination in Bear Creek Burial Grounds  

Broader source: Energy.gov [DOE]

The ORSSAB requests DOE provide possible remedial actions to mitigate releases of contamination from Bear Creek Burial Grounds.

332

GEO Down Under The Ground Source Industry in Australia and New Zealand  

E-Print Network [OSTI]

: 22.2 million § GDP: $987 billion § Per capita GDP: $43 300 per capita § Popula8on: 4.4 million § GDP: $134 billion § Per capita GDP: $30 200 rocks and energy genera8on to most § North side of house has greatest solar

333

Overcoming Barriers to Ground Source Heat Pumps in California  

E-Print Network [OSTI]

Overcoming Barriers to Ground Source Heat Pumps in California Geothermal Resources Development Account http://www.energy.ca.gov/geothermal/ grda.html May 2011 The Issue Ground source heat pumps can far made little impact in California. Estimates are that adoption of ground source heat pumps

334

Remediation of a uranium-contamination in ground water  

SciTech Connect (OSTI)

The former production site of NUKEM where nuclear fuel-elements were developed and handled from 1958 to 1988 was situated in the centre of an industrial park for various activities of the chemical and metallurgical industry. The size of the industrially used part is about 300.000 m{sup 2}. Regulatory routine controls showed elevated CHC (Chlorinated Hydro-Carbons) values of the ground water at the beginning of the 1990's in an area which represented about 80.000 m{sup 2} down-gradient of locations where CHC compounds were stored and handled. Further investigations until 1998 proved that former activities on the NUKEM site, like the UF{sub 6} conversion process, were of certain relevance. The fact that several measured values were above the threshold values made the remediation of the ground water mandatory. This was addressed in the permission given by the Ministry for Nuclear Installations and Environment of Hesse according to chap. 7 of the German atomic law in October 2000. Ground water samples taken in an area of about 5.000 m{sup 2} showed elevated values of total Uranium activity up to between 50 and 75 Bq/l in 2002. Furthermore in an area of another 20.000 m{sup 2} the samples were above threshold value. In this paper results of the remediation are presented. The actual alpha-activities of the ground waters of the remediation wells show values of 3 to 9 Bq/l which are dominated by 80 to 90 % U-234 activity. The mass-share of total Uranium for this nuclide amounts to 0,05% on average. The authority responsible for conventional water utilisation defined target values for remediation: 20 {mu}g/l for dissolved Uranium and 10 {mu}g/l for CHC. Both values have not yet been reached for an area of about 10.000 m{sup 2}. The remediation process by extracting water from four remediation wells has proved its efficiency by reduction of the starting concentrations by a factor of 3 to 6. Further pumping will be necessary especially in that area of the site where the contaminations were found later during soil remediation activities. Only two wells have been in operation since July 2002 when the remediation technique was installed and an apparatus for direct gamma-spectroscopic measurement of the accumulated activities on the adsorbers was qualified. Two further remediation wells have been in operation since August 2006, when the installed remediation technique was about to be doubled from a throughput of 5 m{sup 3}/h to 10 m{sup 3}/h. About 20.000 m{sup 3} of ground water have been extracted since from these two wells and the decrease of their Uranium concentrations behaves similar to that of the two other wells being extracted since the beginning of remediation. Both, total Uranium-concentrations and the weight-share of the nuclides U-234, U-235 and U-238 are measured by ICP-MS (Inductively Coupled Plasma - Mass Spectrometry) besides measurements of Uranium-Alpha-Activities in addition to the measurement of CHC components of which PCE (Per-chlor-Ethene) is dominant in the contaminated area. CHC compounds are measured by GC (Gas Chromatography). Down-gradient naturally attenuated products are detected in various compositions. Overall 183.000 m{sup 3} of ground water have been extracted. Using a pump and treat method 11 kg Uranium have been collected on an ion-exchange material based on cellulose, containing almost 100 MBq U-235 activity, and almost 15 kg of CHC, essentially PCE, were collected on GAC (Granules of Activated Carbon). Less than 3% of the extracted Uranium have passed the adsorber-system of the remediation plant and were adsorbed by the sewage sludge of the industrial site's waste water treatment. The monthly monitoring of 19 monitoring wells shows that an efficient artificial barrier was built up by the water extraction. The Uranium contamination of two ground water plumes has drastically been reduced by the used technique dependent on the amounts of extracted water. The concentration of the CHC contamination has changed depending on the location of temporal pumping. Thereby maximum availability of this contaminan

Woerner, Joerg; Margraf, Sonja; Hackel, Walter [RD Hanau GmbH (Germany)

2007-07-01T23:59:59.000Z

335

Evaluating the Potential Impact of Using the Transport, Aging and Disposal (TAD) Canister on Yucca Mountain Pre-Closure Operations  

SciTech Connect (OSTI)

The development and preliminary use of an integrated model to explore the impact of various operational scenarios of the pre-closure waste management system of Yucca Mountain (YM) is described. The capabilities of the model are illustrated by applying it to a simplified operational scenario using Transport, Aging, and Disposal (TAD) Canisters. The application uses existing data on spent nuclear fuel to model the effect on above ground aging at YM by varying four parameters: (1) utility loading behavior, (2) thermal limit for transportation casks, (3) thermal limit for emplacement, and (4) emplacement capacity at YM. Results show that the thermal limit for emplacement is the most important parameter with respect to above ground aging demands at YM. Transportation heat limit is also important, but less so if the capacity of YM is expanded or if older fuel is sent first. Easing the constraint of the emplacement limit, if feasible, would be a preferable method of reducing aging demands, especially under an expanded emplacement capacity. Consequently, there may be incentive for Department of Energy (DOE) to either specify a lower transportation limit or a higher emplacement limit if it wishes to reduce the potential demands on the Aging Facility at YM. (authors)

Spradley, L. [Research Assistant, Civil and Environmental Engineering, Vanderbilt University, VU Station, Nashville, TN (United States); Abkowitz, M. [Civil and Environmental Engineering, Vanderbilt University (United States); Clarke, J.H. [Civil and Environmental Engineering, Vanderbilt University (United States)

2008-07-01T23:59:59.000Z

336

Testing of a loop heat pipe experimental apparatus under varied acceleration  

E-Print Network [OSTI]

An experimental apparatus was designed and fabricated to test a Loop Heat Pipe under varied acceleration. The experiment consisted of both flight and ground testing as well as comparisons to a model developed from models found in literature...

Kurwitz, Richard Cable

1997-01-01T23:59:59.000Z

337

Materials Under Extremes | ORNL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Home | Science & Discovery | Advanced Materials | Research Areas | Materials Under Extremes SHARE Materials Under Extremes Materials that can withstand extreme conditions such...

338

Limiting factors in ground water remediation  

Science Journals Connector (OSTI)

If one is charged with restoring a contaminated aquifer today, the procedure of pumping contaminated water to the surface for treatment and discharge is most often the state-of-practice technology. The perceived success of pump-and-treat technology can be misleading if the hydrology and contaminant characteristics at the site are not adequately understood. A failure to understand the processes controlling contaminant transport can result in extremely long pumping periods and, consequently, costly and inefficient remediation. Effects of tailing, sorption, and residual immiscible fluids on time required for pump-and-treat remediation of ground water are discussed.

Clinton W. Hall; Jeffrey A. Johnson

1992-01-01T23:59:59.000Z

339

Best Possible Strategy for Finding Ground States  

SciTech Connect (OSTI)

Finding the ground state of a system with a complex energy landscape is important for many physical problems including protein folding, spin glasses, chemical clusters, and neural networks. Such problems are usually solved by heuristic search methods whose efficacy is judged by empirical performance on selected examples. We present a proof that, within the large class of algorithms that simulate a random walk on the landscape, threshold accepting is the best possible strategy. In particular, it can perform better than simulated annealing and Tsallis statistics. Our proof is the first example of a provably optimal strategy in this area.

Franz, Astrid; Hoffmann, Karl Heinz; Salamon, Peter

2001-06-04T23:59:59.000Z

340

Geometric renormalization below the ground state  

E-Print Network [OSTI]

The caloric gauge was introduced by Tao with studying large data energy critical wave maps mapping from $\\mathbf{R}^{2+1}$ to hyperbolic space $\\mathbf{H}^m$ in view. In \\cite{BIKT} Bejenaru, Ionescu, Kenig, and Tataru adapted the caloric gauge to the setting of Schr\\"odinger maps from $\\mathbf{R}^{d + 1}$ to the standard sphere $S^2 \\hookrightarrow \\mathbf{R}^3$ with initial data small in the critical Sobolev norm. Here we develop the caloric gauge in a bounded geometry setting with a construction valid up to the ground state energy.

Paul Smith

2011-12-06T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Provincial Operating Standards (Ontario) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Provincial Operating Standards (Ontario) Provincial Operating Standards (Ontario) Provincial Operating Standards (Ontario) < Back Eligibility Construction Developer Fuel Distributor Industrial Installer/Contractor Investor-Owned Utility Municipal/Public Utility Utility Program Info Start Date 1/24/2002 State Ontario Program Type Environmental Regulations Fees Safety and Operational Guidelines Siting and Permitting Provider Ontario Ministry of Natural Resources The Provincial Operating Standards set the technical minimum requirements for cover wells and works regulated under the Oil, Gas and Salt Resources Act. These standards are the minimum requirements for the design, installation, operation, abandonment and safety of wells and works, but are not intended for use as a design handbook. In addition, the Standards outline the permitting process for injection

342

Simulation and Optimization on Power Plant Operation Using SEGA's EOP Program  

E-Print Network [OSTI]

operation under different conditions was investigated. Further more, (online) operational optimization is made possible by load re-assignment according to EOP's calculation. Other researches on plant operation, such as the impact of utility rates...

Zhou, J.; Deng, S.; Turner, W. D.; Liu, M.

343

Simulation and Optimization on Power Plant Operation Using Sega's EOP Program  

E-Print Network [OSTI]

operation under different conditions was investigated. Further more, (online) operational optimization is made possible by load reassignment according to EOP's calculation. Other researches on plant operation, such as the impact of utility rates...

Zhou, J.; Deng, S.; Turner, W. D.; Liu, M.

2000-01-01T23:59:59.000Z

344

120 Ground Water Monitoring & Remediation 32, no. 1/ Winter 2012/pages 120130 NGWA.org Ground Water Monitoring & Remediation  

E-Print Network [OSTI]

120 Ground Water Monitoring & Remediation 32, no. 1/ Winter 2012/pages 120­130 NGWA.org Ground Water Monitoring & Remediation © 2011, National Ground Water Association. Published 2011. This article known as emerging contaminants (ECs) to surrounding groundwater and surface water. ECs consist

345

CONDUCT OF OPERATIONS (CO)  

Broader source: Energy.gov (indexed) [DOE]

CONDUCT OF OPERATIONS (CO) CONDUCT OF OPERATIONS (CO) OBJECTIVE TA-55 SST Facility NNSA ORR Implementation Plan 1 1 CO.1 The formality and discipline of operations is adequate to conduct work safely and programs are inplace to maintain this formality and discipline. (Core Requirement 13) Criteria 1. Programmatic elements of conduct of operations are in place for TA-55 SST operations. 2. The TA-55 SST operations personnel adequately demonstrate the principles of conduct ofoperations requirements during the shift performance period. Approach Record Reviews: Review procedures and other facility documents to verify compliance with conduct of operations principles. Interviews: Interview a sampling of the TA-55 SST associated personnel to validate their understanding of the conduct of operations principles (e.g., procedure usage,

346

U.S. Department of Energy UMTRA Ground Water Project Ground Water Pumping and Monitoring Plan  

Office of Legacy Management (LM)

GWMON 1.12-1 GWMON 1.12-1 U.S. Department of Energy UMTRA Ground Water Project Ground Water Pumping and Monitoring Plan for the Land Farm Pilot Test Monument Valley, Arizona August 2000 Prepared by U.S. Department of Energy Grand Junction Ofice Grand Junction, Colorado Project Number UGW-5 1 1-001 5-21-000 Document Number U0106701 This page intentionally left blank Document Number U0106701 Contents Contents 1.0 Introduction ....................................................................................................................... 1 2.0 Purpose and Scope ........................................................................................................... 1 3.0 Pilot-Test Extraction Wellfield 2 4.0 Water Elevation Measurements and Monitoring ............... 4

347

TEX-A-SYST: Reducing the Risk of Ground Water Contamination by Improving Household Wastewater Treatment  

E-Print Network [OSTI]

. This publication covers the following topics: 1. Septic tanks/soil absorption systems 2. Quantity of wastewater 3. Quality of wastewater 4. Collection of wastewater 5. Treatment systems 6. Disposal system 7. Assistance with failing systems or new designs 8.... Evaluation table Septic Tanks/Soil Absorption Systems The most common form of on-site waste- water treatment is a septic tank/soil absorption system. In this system, wastewater flows from the household sewage lines into an under- ground septic tank...

Harris, Bill L.; Hoffman, D.; Mazac Jr., F. J.

1997-08-29T23:59:59.000Z

348

Transuranic element uptake and cycling in a forest over an old burial ground  

SciTech Connect (OSTI)

The consequences of returning the Savannah River Site (SRS) burial ground area to general public access at the time of completion of the SRS mission is being investigated. This study includes evaluation of the radiological impact to inhabitants of the area under a number of scenarios that include the return of the land to farming or forestry use with or without exhumation of the buried waste.

Murphy, C.E. Jr.; Tuckfield, J.C.

1992-07-01T23:59:59.000Z

349

Transuranic element uptake and cycling in a forest over an old burial ground  

SciTech Connect (OSTI)

The consequences of returning the Savannah River Site (SRS) burial ground area to general public access at the time of completion of the SRS mission is being investigated. This study includes evaluation of the radiological impact to inhabitants of the area under a number of scenarios that include the return of the land to farming or forestry use with or without exhumation of the buried waste.

Murphy, C.E. Jr.; Tuckfield, J.C.

1992-01-01T23:59:59.000Z

350

Transforming Commercial Building Operations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transforming Commercial Building Operations Transforming Commercial Building Operations Transforming Commercial Building Operations Ron Underhill Pacific Northwest National Laboratory ronald.underhill@pnnl.gov (509)375-9765 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Most buildings are not commissioned (Cx) before occupancy, including HVAC and lighting systems * Buildings often are poorly operated and maintained leading to significant energy waste of 5 to 20%, even when they have building automation systems (BASs)

351

Transforming Commercial Building Operations  

Broader source: Energy.gov (indexed) [DOE]

Transforming Commercial Building Operations Transforming Commercial Building Operations Transforming Commercial Building Operations Ron Underhill Pacific Northwest National Laboratory ronald.underhill@pnnl.gov (509)375-9765 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Most buildings are not commissioned (Cx) before occupancy, including HVAC and lighting systems * Buildings often are poorly operated and maintained leading to significant energy waste of 5 to 20%, even when they have building automation systems (BASs)

352

Quantum Operations and Measurement  

E-Print Network [OSTI]

the Stinespring dilation form of E . 6 #12; II: operator­sum representation E(#) = Tr env # U(## # env )U

Seevinck, Michiel

353

Challenge # 3 ? Operational Issues  

Broader source: Energy.gov [DOE]

Fernando Preto presentation on May 9, 2012, at the Pyrolysis Oil Workshop on Challenge #3 Operational Issues.

354

Operations and maintenance philosophy  

SciTech Connect (OSTI)

This Operations and Maintenance (O&M) Philosophy document is intended to establish a future O&M vision, with an increased focus on minimizing worker exposure, ensuring uninterrupted retrieval operations, and minimizing operation life-cycle cost. It is intended that this document would incorporate O&M lessons learned into on-going and future project upgrades.

DUNCAN, G.P.

1999-10-28T23:59:59.000Z

355

Operating System Resource Management  

E-Print Network [OSTI]

Operating System Resource Management Date: Monday, September 27, 2010 Time: 2:00 ­ 3:00 pm Location allocation and de-allocation by an operating system of processor cores, memory pages, and various types constrained. This talk will propose a scheme for addressing the operating system resource management problem

356

Ground Robot Navigation using Uncalibrated Cameras  

E-Print Network [OSTI]

Precise calibration of camera intrinsic and extrinsic parameters, while often useful, is difficult to obtain during field operation and presents scaling issues for multi-robot systems. We demonstrate a vision-based approach ...

Teller, Seth

357

Performance Assessment Monitoring Plan for the Hanford Site Low-Level Burial Grounds  

SciTech Connect (OSTI)

The U.S. Department of Energy Order 435.1, Radioactive Waste Management, requires a disposal authorization statement authorizing operation (or continued operation) for low-level waste disposal facilities. In fulfillment of these requirements, a disposal authorization statement was issued on October 25, 1999, authorizing the Hanford Site to transfer, receive, possess, and dispose of low-level radioactive waste at the 200 East Area burial grounds and the 200 West Area burial grounds. One of the conditions is that monitoring plans for the 200 East Area and 200 West Area low-level burial grounds be written and approved by the Richland Operations Office. As a result of a record of decision for the Hanford Site Solid Waste Program and acceptance of the Hanford Site Solid Waste Environmental Impact Statement, the use of the low-level burial ground (LLBG) as a disposal facility for low-level and mixed low-level wastes has been restricted to lined trenches and the Navy reactor-compartment trench only. Hence, as of July 2004, only the two lined trenches in burial ground 218-W-5 (trenches 31 and 34, see Appendix A) and the Navy reactor-compartment trench in burial ground 218 E 12B (trench 94) are allowed to receive waste. When the two lined trenches are filled, the LLBG will cease to operate except for reactor compartment disposal at trench 94. Remaining operational lifetime of the LLBG is dependent on waste volume disposal rates. Existing programs for air sampling and analyses and subsidence monitoring are currently adequate for performance assessment at the LLBG. The waste disposal authorization for the Hanford Site is based (in part) on the post-closure performance assessments for the LLBG. In order to maintain a useful link between operational monitoring (e.g., Resource Conservation and Recovery Act [RCRA], Comprehensive Environmental Response, Compensation, and Liability Act, and State Waste Discharge Permits), constituents, monitoring frequencies, and boundaries require regular review and comparison. The annual reports discussed here are the primary sources for these reviews. The pathways of interest are air and groundwater for both operational and post-closure conditions at the LLBG, with groundwater considered to be the most significant long-term exposure pathway. Constituents that contributed at least 0.1% of the total relative hazard were selected as target analytes for monitoring. These are technetium-99, uranium, and iodine-129. Because of its environmental unavailability, carbon 14 was removed from the list of constituents. Given the potential uncertainties in inventories at the 200 Area LLBG and the usefulness of tritium as a contaminant indicator, tritium will be monitored as a constituent of concern at all burial grounds. Preexisting contamination plumes in groundwater beneath low-level waste management areas are attributed to other past-practice liquid waste disposal sites. Groundwater and air will be sampled and analyzed for radiogenic components. Subsidence monitoring will also be performed on a regular basis. The existing near-facility and surveillance air monitoring programs are sufficient to satisfy the performance assessment monitoring. Groundwater monitoring will utilize the existing network of wells at the LLBG, and co-sampling with RCRA groundwater monitoring, to be sampled semiannually. Installation of additional wells is currently underway to replace wells that have gone dry.

None

2006-03-30T23:59:59.000Z

358

Atmospheric bromine flux from the coastal Abu Dhabi sabkhat: A ground-water mass-balance investigation  

E-Print Network [OSTI]

2007; published 31 July 2007. [1] A solute mass-balance study of ground water of the 3000 km2 coastal area of active salt flats then it is a significant, and generally under recognized, input to the global., 2000; Keppler et al., 2000]. More relevant to this study area are reports in which bromide appears

359

hal-00283932,version1-1Jun2008 Operating an atom interferometer beyond its linear range  

E-Print Network [OSTI]

associated to the auxiliary measurement of external vibrations, can be operated beyond its linear range vibration isolation, the use of a low noise seismometer for the measurement of ground vibrations allows our of the measurement to large vibration noise is also demonstrated by the ability of our gravimeter to operate during

Paris-Sud XI, Université de

360

Data Assimilation of Lightning in WRF 3/4-D VAR Using Observation Operators  

E-Print Network [OSTI]

@fsu.edu Abstract Compared to other types of satellite-derived data, assimilating lightning data into operationalData Assimilation of Lightning in WRF 3/4-D VAR Using Observation Operators Razvan S¸tefanescu1. The early stages of our research will utilize existing ground-based lightning data that can be assimilated

Navon, Michael

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Definition: Ground Magnetics | Open Energy Information  

Open Energy Info (EERE)

Magnetics Magnetics Jump to: navigation, search Dictionary.png Ground Magnetics The surface magnetic method is the study of the distribution of magnetic minerals in the upper 20-30km of the earth's crust, recorded at an observation point on the earth's surface.[1][2] View on Wikipedia Wikipedia Definition A magnetometer, (pronounced mag-ne-TOM-e-ter), is a measuring instrument used to measure the strength and/or direction of the magnetic field, produced either in the laboratory or existing in nature. Some countries such as the USA, Canada and Australia classify the more sensitive magnetometers as military technology, and control their distribution. The International System of Units unit of measure for the strength of a magnetic field is the Tesla. This is a very large unit of magnetic field.

362

Wide band stepped frequency ground penetrating radar  

DOE Patents [OSTI]

A wide band ground penetrating radar system (10) embodying a method wherein a series of radio frequency signals (60) is produced by a single radio frequency source (16) and provided to a transmit antenna (26) for transmission to a target (54) and reflection therefrom to a receive antenna (28). A phase modulator (18) modulates those portion of the radio frequency signals (62) to be transmitted and the reflected modulated signal (62) is combined in a mixer (34) with the original radio frequency signal (60) to produce a resultant signal (53) which is demodulated to produce a series of direct current voltage signals (66) the envelope of which forms a cosine wave shaped plot (68) which is processed by a Fast Fourier Transform unit 44 into frequency domain data (70) wherein the position of a preponderant frequency is indicative of distance to the target (54) and magnitude is indicative of the signature of the target (54).

Bashforth, Michael B. (Buellton, CA); Gardner, Duane (Santa Maria, CA); Patrick, Douglas (Santa Maria, CA); Lewallen, Tricia A. (Ventura, CA); Nammath, Sharyn R. (Santa Barbara, CA); Painter, Kelly D. (Goleta, CA); Vadnais, Kenneth G. (Alexandria, VA)

1996-01-01T23:59:59.000Z

363

Quality Assurance: Underlying Quality Principles  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Underlying Quality Principles Underlying Quality Principles These principles are consistent with Integrated Safety Management Policy, P 450.4A and support ISM implementation. Define Policies and Objectives--Ensure they are Understood and Accepted. Management must set expectations for the organization as a whole before employees can do their jobs, satisfy their customers, and strive to improve the quality of their work. This is accomplished by developing and implementing specific policies and objectives that reflect the operating philosophy of the facility's management. Once these policies and objectives have been established, all managers must take the necessary actions to ensure that each employee shares their vision of the organization's purpose. Specify Roles and Responsibilities--Ensure they are Understood and Accepted.

364

Methods of minimizing ground-water contamination from in situ leach uranium mining. Final report  

SciTech Connect (OSTI)

This is the final report of a research project designed to study methods of minimizing ground-water contamination from in situ leach uranium mining. Fieldwork and laboratory experiments were conducted to identify excursion indicators for monitoring purposes during mining, and to evaluate effective aquifer restoration techniques following mining. Many of the solution constituents were found to be too reactive with the aquifer sediments to reliably indicate excursion of leaching solution from the ore zone; however, in many cases, the concentrations of chloride and sulfate and the total dissolved solids level of the solution were found to be good excursion indicators. Aquifer restoration by ground-water sweeping consumed large quantities of ground water and was not effective for the redox-sensitive contaminants often present in the ore zone. Surface treatment methods such as reverse osmosis and electrodialysis were effective in reducing the amount of water used, but also had the potential for creating conditions in the aquifer under which the redox-sensitive contaminants would be mobile. In situ restoration by chemical reduction, in which a reducing agent is added to the solution recirculated through the ore zone during restoration, can restore the ore-zone sediment as well as the ground water. This method could lead to a stable chemical condition in the aquifer similar to conditions before mining. 41 figures.

Deutsch, W.J.; Martin, W.J.; Eary, L.E.; Serne, R.J.

1985-03-01T23:59:59.000Z

365

Lossless anomalous dispersion and an inversionless gain doublet via dressed interacting ground states  

SciTech Connect (OSTI)

Transparent media exhibiting anomalous dispersion have been of considerable interest since Wang, Kuzmich, and Dogariu [Nature 406, 277 (2000)] first observed light propagate with superluminal and negative group velocities without absorption. Here, we propose an atomic model exhibiting these properties, based on a generalization of amplification without inversion in a five-level dressed interacting ground-state system. The system consists of a {Lambda} atom prepared as in standard electromagnetically induced transparency (EIT), with two additional metastable ground states coupled to the {Lambda} atom ground states by two rf-microwave fields. We consider two configurations by which population is incoherently pumped into the ground states of the atom. Under appropriate circumstances, we predict a pair of new gain lines with tunable width, separation, and height. Between these lines, absorption vanishes but dispersion is large and anomalous. The system described here is a significant improvement over other proposals in the anomalous dispersion literature in that it permits additional coherent control over the spectral properties of the anomalous region, including a possible 10{sup 4}-fold increase over the group delay observed by Wang, Kuzmich, and Dogariu.

Weatherall, James Owen [Department of Physics and Engineering Physics, Stevens Institute of Technology, Castle Point on Hudson, Hoboken, New Jersey 07030 (United States); Department of Mathematical Sciences, Stevens Institute of Technology, Castle Point on Hudson, Hoboken, New Jersey 07030 (United States); Department of Logic and Philosophy of Science, University of California Irvine, 3151 Social Science Plaza A, Irvine, California 92697 (United States); Search, Christopher P. [Department of Physics and Engineering Physics, Stevens Institute of Technology, Castle Point on Hudson, Hoboken, New Jersey 07030 (United States)

2010-02-15T23:59:59.000Z

366

Independent Specific Administrative Controls Review, Richland Operations  

Broader source: Energy.gov (indexed) [DOE]

Independent Specific Administrative Controls Review, Richland Independent Specific Administrative Controls Review, Richland Operations Office - December 2010 Independent Specific Administrative Controls Review, Richland Operations Office - December 2010 December 2010 Specific Administrative Controls Review with the Office of Environmental Management at DOE-Richland Operations Office The U.S. Department of Energy (DOE) Office of Independent Oversight, within the Office of Health, Safety and Security, participated in the Office of Environmental Management Office of Standards and Quality Assurance, EM-23, review of Specific Administrative Controls (SAC) at the Hanford Site. The EM-23 review included selected programs at the Hanford Site that are under the auspices of the DOE Richland Operations Office. Independent Specific Administrative Controls Review, Richland Operations

367

Definition: Operating Reserve - Spinning | Open Energy Information  

Open Energy Info (EERE)

Reserve - Spinning Reserve - Spinning Jump to: navigation, search Dictionary.png Operating Reserve - Spinning The portion of Operating Reserve consisting of: Generation synchronized to the system and fully available to serve load within the Disturbance Recovery Period following the contingency event; or, Load fully removable from the system within the Disturbance Recovery Period following the contingency event.[1] View on Wikipedia Wikipedia Definition In electricity networks, the operating reserve is the generating capacity available to the system operator within a short interval of time to meet demand in case a generator goes down or there is another disruption to the supply. Most power systems are designed so that, under normal conditions, the operating reserve is always at least the capacity of the

368

Definition: Operating Reserve - Supplemental | Open Energy Information  

Open Energy Info (EERE)

Supplemental Supplemental Jump to: navigation, search Dictionary.png Operating Reserve - Supplemental The portion of Operating Reserve consisting of: Generation (synchronized or capable of being synchronized to the system) that is fully available to serve load within the Disturbance Recovery Period following the contingency event; or, Load fully removable from the system within the Disturbance Recovery Period following the contingency event.[1] View on Wikipedia Wikipedia Definition In electricity networks, the operating reserve is the generating capacity available to the system operator within a short interval of time to meet demand in case a generator goes down or there is another disruption to the supply. Most power systems are designed so that, under normal conditions, the operating reserve is always at least the capacity of the

369

Building Operator Certification  

E-Print Network [OSTI]

programmed settings review ? Verify damper settings ? Check static pressure sensor calibration ? Review occupant complaint records and remedies ? Review established temperature set points HVAC Controls Operational Review ESL-KT-13-12-49 CATEE 2013: Clean... Operator Certification Energy Efficiency through Operator Training BOC Has Two Levels • Level I: Building Systems Maintenance ? Two or more years experience (5 yrs avg) ? Outcome: Basic understanding of electrical, HVAC and lighting systems...

Lilley, D.

2013-01-01T23:59:59.000Z

370

Operations Cost Allocation Project  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Operations Consolidation Project Operations Consolidation Project Operations Consolidation Project (OCP) Cost Allocation Presentation - September 20, 2011 OCP Cost Allocation Customer Presentation List of Acronyms OCP Cost Allocation Spreadsheets OCP Cost Allocation Customer Presentation - Questions and Answers - September 19 - 20, 2011 Additional Questions and Answers Customer Comments/Questions and Answers: Arizona Municipal Power Users Association Arizona Power Authority Central Arizona Project Colorado River Commission Colorado River Energy Distributors Association City of Gilbert, AZ Irrigation and Electrical Districts Association of Arizona Town of Marana, AZ City of Mesa, AZ Town of Wickenburg, AZ Western's Final Decision Regarding the Long-Term Cost Allocation Methodology for Operations Staff Costs

371

Business Operations Contacts  

Office of Energy Efficiency and Renewable Energy (EERE)

If you have a question for the Office of Business Operations, you can use this contact information to reach the office you're interested in:

372

Semicausal operations are semilocalizable  

E-Print Network [OSTI]

We prove a conjecture by DiVincenzo, which in the terminology of Preskill et al. [quant-ph/0102043] states that ``semicausal operations are semilocalizable''. That is, we show that any operation on the combined system of Alice and Bob, which does not allow Bob to send messages to Alice, can be represented as an operation by Alice, transmitting a quantum particle to Bob, and a local operation by Bob. The proof is based on the uniqueness of the Stinespring representation for a completely positive map. We sketch some of the problems in transferring these concepts to the context of relativistic quantum field theory.

Eggeling, T; Werner, R F

2002-01-01T23:59:59.000Z

373

Fermilab | Tevatron | Tevatron Operation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Operation Fermilab's Accelerator Complex Fermilab's Accelerator Complex has 10 accelerators. The Tevatron, which shuts down on Sept. 30, is one of those accelerators. The...

374

Pipeline Operations Program (Louisiana)  

Broader source: Energy.gov [DOE]

The Pipeline Operations Program regulates the construction, acquisition, abandonment and interconnection of natural gas pipelines, as well as, the transportation and use of natural gas supplies.

375

Richland Operations Office  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

treatment and the data should be available by the end of next week. * Status Conduct of Operations There have been several small incidents recently where observations of work...

376

Challenge # 3 ? Operational Issues  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Potential for a renewable heating oil substitution Challenge 3 - Operational Issues What are the most significant barriers to overcome in each market segment? Fernando Preto The...

377

A Highly Agile Ground Assessment Robot (HAGAR) for military battlefield and support missions  

SciTech Connect (OSTI)

A mobile robotic vehicle with potential for use in military field applications is described. Based on a Sandia design intended for use in exploration of the Lunar surface, the Highly Agile Ground Assessment Robot (HAGAR) is a four wheeled all-wheel-drive dual-body vehicle. A uniquely simple method of chassis articulation is employed which allows all four wheels to remain in contact with the ground, even while operating in very rough terrain and climbing over obstacles as large as a wheel diameter. Skid steering and modular construction are used to produce a simple, rugged, lightweight, highly agile mobility chassis with a reduction in the number of parts required when compared to conventional vehicle designs for military battlefield and support missions. The design configuration, mobility parameters, potential mission configurations, and performance of existing and proposed HAGAR prototypes are discussed.

Klarer, P.

1994-04-01T23:59:59.000Z

378

Ground Magnetics At Marysville Mt Area (Blackwell) | Open Energy  

Open Energy Info (EERE)

Ground Magnetics At Marysville Mt Area (Blackwell) Ground Magnetics At Marysville Mt Area (Blackwell) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Magnetics At Marysville Mt Area (Blackwell) Exploration Activity Details Location Marysville Mt Area Exploration Technique Ground Magnetics Activity Date Usefulness not useful DOE-funding Unknown Notes A ground magnetic survey located no anomaly with an amplitude of more than 20 or 30 gammas that could be associated with the thermal anomaly, however the magnetic data did outline the Cretaceous stock in great detail and allow the removal from the gravity field of the effect of the stock. References D. D. Blackwell (Unknown) Exploration In A Blind Geothermal Area Near Marysville, Montana, Usa Retrieved from "http://en.openei.org/w/index.php?title=Ground_Magnetics_At_Marysville_Mt_Area_(Blackwell)&oldid=389390"

379

Sun--Grounding Social Sciences in Cognitive Sciences I Introduction  

E-Print Network [OSTI]

G Sun--Grounding Social Sciences in Cognitive Sciences I Introduction Sun_8928_001_main.indd 1 1/10/2012 6:35:15 PM #12;G Sun--Grounding Social Sciences in Cognitive Sciences Sun_8928_001_main.indd 2 1/10/2012 6:35:15 PM #12;G Sun--Grounding Social Sciences in Cognitive Sciences 1 Prolegomenato

Sun, Ron

380

Exceptional Ground Accelerations and Velocities Caused by Earthquakes  

SciTech Connect (OSTI)

This project aims to understand the characteristics of the free-field strong-motion records that have yielded the 100 largest peak accelerations and the 100 largest peak velocities recorded to date. The peak is defined as the maximum magnitude of the acceleration or velocity vector during the strong shaking. This compilation includes 35 records with peak acceleration greater than gravity, and 41 records with peak velocities greater than 100 cm/s. The results represent an estimated 150,000 instrument-years of strong-motion recordings. The mean horizontal acceleration or velocity, as used for the NGA ground motion models, is typically 0.76 times the magnitude of this vector peak. Accelerations in the top 100 come from earthquakes as small as magnitude 5, while velocities in the top 100 all come from earthquakes with magnitude 6 or larger. Records are dominated by crustal earthquakes with thrust, oblique-thrust, or strike-slip mechanisms. Normal faulting mechanisms in crustal earthquakes constitute under 5% of the records in the databases searched, and an even smaller percentage of the exceptional records. All NEHRP site categories have contributed exceptional records, in proportions similar to the extent that they are represented in the larger database.

Anderson, John

2008-01-17T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

A GROUND-BASED 21 cm BARYON ACOUSTIC OSCILLATION SURVEY  

SciTech Connect (OSTI)

Baryon acoustic oscillations (BAO) provide a robust standard ruler with which to measure the acceleration of the universe. The BAO feature has so far been detected in optical galaxy surveys. Intensity mapping of neutral hydrogen emission with a ground-based radio telescope provides another promising window for measuring BAO at redshifts of order unity for relatively low cost. While the cylindrical radio telescope (CRT) proposed for these measurements will have excellent redshift resolution, it will suffer from poor angular resolution (arcminutes at best). We investigate the effect of angular resolution on the standard ruler test with BAO, using the Dark Energy Task Force Figure of Merit (FoM) as a benchmark. We then extend the analysis to include variations in the parameters characterizing the telescope and the underlying physics. Finally, we optimize the survey parameters (holding total cost fixed) and present an example of a CRT BAO survey that is competitive with Stage III dark energy experiments. The tools developed here form the backbone of a publicly available code that can be used to obtain estimates of cost and FoM for any set of survey parameters.

Seo, Hee-Jong; Dodelson, Scott; Marriner, John; Mcginnis, Dave; Stebbins, Albert; Stoughton, Chris; Vallinotto, Alberto, E-mail: sheejong@fnal.go [Center for Particle Astrophysics, Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, IL 60510-5011 (United States)

2010-09-20T23:59:59.000Z

382

Ground Gravity Survey At Dixie Valley Geothermal Area (Schaefer...  

Open Energy Info (EERE)

Area (Schaefer, 1983) Exploration Activity Details Location Dixie Valley Geothermal Area Exploration Technique Ground Gravity Survey Activity Date 1983 - 1983 Usefulness...

383

5-MW Dynamometer Ground Breaking | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Energy Laboratory in Golden, Colorado, broke ground for a new 5-MW dynamometer test facility. When complete, the new facility will more than double the wind turbine...

384

Española entrepreneur breaks ground; expansion will create 50...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Espaola entrepreneur breaks ground; expansion will create 50 new jobs Community Connections: Your link to news and opportunities from Los Alamos National Laboratory Latest Issue:...

385

Posters Preliminary Analysis of Ground-Based Microwave and Infrared...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 Posters Preliminary Analysis of Ground-Based Microwave and Infrared Radiance Observations During the Pilot Radiation OBservation Experiment E. R. Westwater, Y. Han, J. H....

386

Hybrid Ground Source System Analysis and Tool Development  

Broader source: Energy.gov (indexed) [DOE]

Development Principal Investigator Scott Hackel, Energy Center of Wisconsin Ground Source Heat Pumps Demonstration Projects May 18, 2010 This presentation does not contain any...

387

Building America Case Study: Ground Source Heat Pump Research...  

Energy Savers [EERE]

a home during design and carefully sizing expensive systems such as ground source heat pumps (GSHPs) will result in a closer correlation between modeled and actual energy...

388

EVALUATION AND OPTIMIZATION RESEARCH OF GROUND SOURCE HEAT PUMP.  

E-Print Network [OSTI]

??Nowadays energy efficiency and environmental protection have got particular attention. After the sustainable development theory had been put forward decades ago. Ground source heat pump… (more)

Zhou, Taian

2011-01-01T23:59:59.000Z

389

Trimming of a ground source heat pump system in Saltsjöbaden.  

E-Print Network [OSTI]

?? The real performance of ground source heat pumps systems are not precisely highlighted in most cases, especially when it comes to installations older than… (more)

Garnier, Michel

2014-01-01T23:59:59.000Z

390

Monitoring SERC Technologies —Geothermal/Ground Source Heat Pumps  

Broader source: Energy.gov [DOE]

A webinar by National Renewable Energy Laboratory Project Leader Dave Peterson about Geothermal/Ground Source Heat Pumps and how to properly monitor its installation.

391

LANL breaks ground on key sediment control project  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Sediment control project LANL breaks ground on key sediment control project Called "grade-control" structures, the approximately 2 million features are up to eight feet high and...

392

BURNING GROUND RD CDV-SMA-2.3  

E-Print Network [OSTI]

GROUND BUNKER 430 ANCHORRANCH V-SITE 260 332 RESTHOUSE 410 360 PLASTICS Cañon de Valle S-Site Canyon Fish

393

Ground Gravity Survey At Long Valley Caldera Geothermal Area...  

Open Energy Info (EERE)

Battaglia, Et Al., 2003) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Gravity Survey At Long Valley Caldera Geothermal Area (Battaglia,...

394

Ground Magnetics At Cove Fort Area - Vapor (Warpinski, Et Al...  

Open Energy Info (EERE)

Vapor (Warpinski, Et Al., 2004) Exploration Activity Details Location Cove Fort Geothermal Area Exploration Technique Ground Magnetics Activity Date Usefulness useful DOE-funding...

395

Ground Gravity Survey At Cove Fort Area - Vapor (Warpinski, Et...  

Open Energy Info (EERE)

Vapor (Warpinski, Et Al., 2004) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Gravity Survey At Cove Fort Area - Vapor (Warpinski, Et...

396

Ground Water Management District Rules | Open Energy Information  

Open Energy Info (EERE)

District Rules Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Ground Water Management District Rules Abstract This webpage provides information...

397

.JETEQUIPMENT &TOOLS OPERATOR'S MANUAL  

E-Print Network [OSTI]

.JETEQUIPMENT &TOOLS OPERATOR'S MANUAL JDP-14J/14M/17M/14JF/14 MF/17MF DRILL PRESS Stock No. .JET-6000 FAX[253] 939-8001 #12;OPERATINGINSTRUCTIONS Before operating the unit, please read this manual workpiece. 7. MAINTAIN TOOLS WITH CARE. Keep tools sharp and clean for the best and safest performance

Kleinfeld, David

398

Operability and Emissions from a Medium-Duty Fleet Operating...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Operability and Emissions from a Medium-Duty Fleet Operating with GTL Fuel and Catalyzed DPFs Operability and Emissions from a Medium-Duty Fleet Operating with GTL Fuel and...

399

Fracture-zone dewatering to control ground water inflow in underground coal mines. Report of Investigations/1985  

SciTech Connect (OSTI)

The Bureau of Mines investigation focuses on the identification and control of ground-water inflow problems that occur in the active sections of underground Appalachian coal mines. A fracture inflow survey of eight underground mines was conducted. Three types of mine fracture intercepts were identified, which are typical of wet section mining conditions. A mine in Preston County, WV was selected as the site for a fracture-zone dewatering experiment. Fracture trace analysis was used to site dewatering wells in a fracture valley setting ahead of mine development. The design, implementation, and results of the dewatering experiment are presented. The investigation suggests that fracture zones are responsible for the sudden release of stored ground water, which often occurs as mining sections advance beneath fracture valley topography. It is concluded, therefore, that dewatering operations that are designed to intercept the component of ground water that is stored in fracture zones will be most effective in controlling infiltration to active mine sections.

Schmidt, R.D.

1985-01-01T23:59:59.000Z

400

Ground-Based Microwave Study of LWP Spatial Anisotropy in Winter Clouds  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ground-Based Microwave Study of LWP Spatial Ground-Based Microwave Study of LWP Spatial Anisotropy in Winter Clouds A. V. Koldaev, E. A. Miller, V. E. Kadygrov, and A. I. Gusev Central Aerological Observatory Moscow, Russia A. V. Troitsky Radio Physics Institute of Nigny Novgorod, Russia W. Strapp Meteorological Service of Canada Cloud Physics Research Division Ottawa, Canada Introduction The role of horizontal anisotropy of the cloud field in the radiation transfer is under investigation of Atmospheric Radiation Measurement (ARM) science team since the beginning of the program. It was recognized within last few years that the inhomogeneity of clouds could lead to large errors in heat fluxes calculations. It was calculated and experimentally proved (Gorchakova, Golitsyn et al. 2001) that

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Application Analysis of Ground Source Heat Pumps in Building Space Conditioning  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Application Analysis of Ground Source Heat Application Analysis of Ground Source Heat Pumps in Building Space Conditioning Hua Qian 1,2 , Yungang Wang 2 1 School of Energy and Environment Southeast University Nanjing, 210096, China 2 Environmental Energy Technologies Division Lawrence Berkeley National Laboratory Berkeley, CA 94720, USA July 2013 The project was supported by National Key Technology Supported Program of China (2011BAJ03B10-1) and by the U.S. Department of Energy under Contract No. DE-AC02- 05CH11231. Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the

402

Ground Gravity Survey At Valles Caldera - Redondo Area (Wilt & Haar, 1986)  

Open Energy Info (EERE)

Gravity Survey At Valles Caldera - Redondo Area (Wilt & Haar, 1986) Gravity Survey At Valles Caldera - Redondo Area (Wilt & Haar, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Gravity Survey At Valles Caldera - Redondo Area (Wilt & Haar, 1986) Exploration Activity Details Location Valles Caldera - Redondo Area Exploration Technique Ground Gravity Survey Activity Date Usefulness not indicated DOE-funding Unknown Notes A computer program capable of two-dimensional modeling of gravity data was used in interpreting gravity observations along profiles A--A' and B--B' (Talwani et al., 1959). Densities of 2.12, 2.40, and 2.65 g/cm a were used for modeling the near-surface caldera fill, the underlying volcanics, and the basement sections, respectively (Fig. 8). Although correlation with

403

Ground Gravity Survey At Valles Caldera - Sulphur Springs Area (Wilt &  

Open Energy Info (EERE)

Valles Caldera - Sulphur Springs Area (Wilt & Valles Caldera - Sulphur Springs Area (Wilt & Haar, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Gravity Survey At Valles Caldera - Sulphur Springs Area (Wilt & Haar, 1986) Exploration Activity Details Location Valles Caldera - Sulphur Springs Area Exploration Technique Ground Gravity Survey Activity Date Usefulness not indicated DOE-funding Unknown Notes A computer program capable of two-dimensional modeling of gravity data was used in interpreting gravity observations along profiles A--A' and B--B' (Talwani et al., 1959). Densities of 2.12, 2.40, and 2.65 g/cm a were used for modeling the near-surface caldera fill, the underlying volcanics, and the basement sections, respectively (Fig. 8). Although correlation with

404

Introduction Application of numerical models of ground water flow  

E-Print Network [OSTI]

(Portniaguine and Solomon 1998), and ground water temperature (Doussan et al. 1994). Compared to calibration depended on calibration methodology; models calibrated with multiple targets simulated q more accurately of Calibration Methodology on Ground Water Flow Predictions by James E. Saiers1, David P. Genereux2, and Carl H

Saiers, James

405

A ROUGHENING TRANSITION INDICATED BY THE BEHAVIOUR OF GROUND STATES  

E-Print Network [OSTI]

A ROUGHENING TRANSITION INDICATED BY THE BEHAVIOUR OF GROUND STATES R. Koteck´y and S. Miracle of classical lattice models, one may meet some interesting and non-trivial structures. Keywords: Roughening for the stability of rigid ground states has been conjectured hal-00706981,version1-11Jun2012 #12;Roughening

Paris-Sud XI, Université de

406

Ground-Source Heat Pumps in Cold Climates  

E-Print Network [OSTI]

Ground-Source Heat Pumps in Cold Climates The Current State of the Alaska Industry, a Review-Source Heat Pumps in Cold Climates The Current State of the Alaska Industry, a Review of the Literature and contributions from individuals and organizations involved in ground-source heat pump installation around Alaska

Wagner, Diane

407

Ground-Coupled Heat Pump Applications and Case Studies  

E-Print Network [OSTI]

to a similar bank building with air-conditioning and gas for heat revealed a 22 percent reduction in utility costs for the ground-coupled building. In a retrofit application of ground-coupled heat pumps to replace air-conditioning and electric heal...

Braud, H. J.

1989-01-01T23:59:59.000Z

408

Elastic Properties of Jet-Grouted Ground and Applications  

E-Print Network [OSTI]

consists in using injection pressures of the same order of magnitude as in hydro-fracturing. The ground heave resulting from the increase of pore pressure in the cracks is expected to compensate the settlements occurring in the cracked ground. Compaction...-2-4 Compensation Grouting ................................................................................ 9 2-2-5 Compaction Grouting.................................................................................... 9 2-2-6 Permeation Grouting...

Juge, Benjamin

2012-07-16T23:59:59.000Z

409

Description of ground motion data processing codes: Volume 3  

SciTech Connect (OSTI)

Data processing codes developed to process ground motion at the Nevada Test Site for the Weapons Test Seismic Investigations Project are used today as part of the program to process ground motion records for the Nevada Nuclear Waste Storage Investigations Project. The work contained in this report documents and lists codes and verifies the ``PSRV`` code. 39 figs.

Sanders, M.L.

1988-02-01T23:59:59.000Z

410

Integrated Water Management Options in the Nebraska Ground Water Management &  

E-Print Network [OSTI]

Integrated Water Management Options in the Nebraska Ground Water Management & Protection Act by J of the Nebraska Ground Water Management & Protection Act (GMPA) 2. the special GMPA integrated water management a correlative rights framework, and 5. what additional water management tools are needed to effectively deal

Nebraska-Lincoln, University of

411

Possible Ground-State Octupole Deformation in Pa229  

Science Journals Connector (OSTI)

Evidence is presented for the occurrence of a 52± parity doublet as the ground state of Pa229, in agreement with a previous theoretical prediction. The doublet splitting energy is measured to be 0.22±0.05 keV. The relation of this doublet to ground-state octupole deformation is discussed.

I. Ahmad; J. E. Gindler; R. R. Betts; R. R. Chasman; A. M. Friedman

1982-12-13T23:59:59.000Z

412

Cost Benefit Analysis Modeling Tool for Electric vs. ICE Airport Ground Support Equipment – Development and Results  

SciTech Connect (OSTI)

This report documents efforts to develop a computer tool for modeling the economic payback for comparative airport ground support equipment (GSE) that are propelled by either electric motors or gasoline and diesel engines. The types of GSE modeled are pushback tractors, baggage tractors, and belt loaders. The GSE modeling tool includes an emissions module that estimates the amount of tailpipe emissions saved by replacing internal combustion engine GSE with electric GSE. This report contains modeling assumptions, methodology, a user’s manual, and modeling results. The model was developed based on the operations of two airlines at four United States airports.

James Francfort; Kevin Morrow; Dimitri Hochard

2007-02-01T23:59:59.000Z

413

Ground-truth aerosol lidar observations: can the Klett solutions obtained from ground and space be equal for the same aerosol case?  

Science Journals Connector (OSTI)

Upcoming multiyear satellite lidar aerosol observations need strong support by a worldwide ground-truth lidar network. In this context the question arises as to whether the ground...

Ansmann, Albert

2006-01-01T23:59:59.000Z

414

Ground Magnetics At Alum Area (DOE GTP) | Open Energy Information  

Open Energy Info (EERE)

Ground Magnetics At Alum Area (DOE GTP) Ground Magnetics At Alum Area (DOE GTP) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Magnetics At Alum Geothermal Area (DOE GTP) Exploration Activity Details Location Alum Geothermal Area Exploration Technique Ground Magnetics Activity Date Usefulness not indicated DOE-funding Unknown References (1 January 2011) GTP ARRA Spreadsheet Retrieved from "http://en.openei.org/w/index.php?title=Ground_Magnetics_At_Alum_Area_(DOE_GTP)&oldid=402978" Categories: Exploration Activities DOE Funded Activities ARRA Funded Activities What links here Related changes Special pages Printable version Permanent link Browse properties About us Disclaimers Energy blogs Linked Data Developer services OpenEI partners with a broad range of international organizations to grow

415

Operations Research Analysts  

U.S. Energy Information Administration (EIA) Indexed Site

Operations Research Analysts Operations Research Analysts The U.S. Energy Information Administration (EIA) within the Department of Energy has forged a world-class information program that stresses quality, teamwork, and employee growth. In support of our program, we offer a variety of profes- sional positions, including the Operations Research Analyst, whose work is associated with the development and main- tenance of energy modeling systems. Responsibilities: Operations Research Analysts perform or participate in one or more of the following important functions: * Develop, design, perform, and document a broad range of analyses and studies involving current and projected energy pricing, production, supply, and distribution, and consumption * Using computer programming skills and knowledge of energy industries and markets, designs and develops math-

416

Field Operations Program  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

688 688 May 1999 Field Operations Program Activities Status Report Fiscal Years 1997 through mid-1999 J. E. Francfort D. V. O'Hara L. A. Slezak DOE/ID-10688 Field Operations Program Activities Status Report Fiscal Years 1997 through mid-1999 J. E. Francfort 1 D. V. O'Hara 2 L. A. Slezak 2 Published May 1999 Idaho National Engineering and Environmental Laboratory Automotive Systems and Technology Department Lockheed Martin Idaho Technologies Company Idaho Falls, Idaho 83415 Prepared for the U.S. Department of Energy Idaho Operations Office 1 INEEL/Lockheed Martin Idaho Technologies Co. 2 U.S. Department of Energy iii EXECUTIVE SUMMARY The Field Operations Program is an electric vehicle testing and evaluation program sponsored by U.S. Department of Energy and managed by the Idaho National Engineering and Environmental

417

Operational Area Monitoring Plan  

Office of Legacy Management (LM)

' ' SECTION 11.7B Operational Area Monitoring Plan for the Long -Term H yd rol og ical M o n i to ri ng - Program Off The Nevada Test Site S . C. Black Reynolds Electrical & Engineering, Co. and W. G. Phillips, G. G. Martin, D. J. Chaloud, C. A. Fontana, and 0. G. Easterly Environmental Monitoring Systems Laboratory U. S. Environmental Protection Agency October 23, 1991 FOREWORD This is one of a series of Operational Area Monitoring Plans that comprise the overall Environmental Monitoring Plan for the DOE Field Office, Nevada (DOEINV) nuclear and non- nuclear testing activities associated with the Nevada Test Site (NTS). These Operational Area Monitoring Plans are prepared by various DOE support contractors, NTS user organizations, and federal or state agencies supporting DOE NTS operations. These plans and the parent

418

Operations Research Analyst  

Broader source: Energy.gov [DOE]

A successful candidate in this position will serve as an Operations Research Analyst assigned to CEPE, in Washington, DC and is responsible for conducting independent cost and schedule estimates of...

419

Oak Ridge Operations.  

Office of Legacy Management (LM)

4s - 22 Department of Energy Oak Ridge Operations. SI9J>liB P.O. Box 2001 Oak Ridge. Tennessee 37831-8723 October 21, 1994 Mr. Charles A. Duritsa Regional Director...

420

Operating Oak Ridge's "Calutrons"  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

RIDGE'S CALUTRONS: In this oral history, Theodore Rockwell talks about the Y-12 plant at Oak Ridge where the calutrons were operated by young women, many just out of high school....

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Oak Ridge Operations YTO  

Office of Legacy Management (LM)

ed States Government Department of Energy Oak Ridge Operations YTO r , , EM-93:Hartman I - CATEGORICAL EXCLUSION (CX) DETERMINATION - RMOVAL ACTION AT M E SPRINGDALE r SITE I -a...

422

Operations Security Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To establish policies, responsibilities and authorities for implementing and sustaining the Department of Energy (DOE) Operations Security (OPSEC) Program. Cancels DOE O 5632.3B. Canceled by DOE O 471.2 of 9-28-1995.

1992-04-30T23:59:59.000Z

423

Operations and Maintenance  

Broader source: Energy.gov [DOE]

Lower operations and maintenance (O&M) costs are critical to reducing a solar system's lifecycle cost of ownership. O&M costs are influenced by up-front investments in design, engineering,...

424

Operating plan FY 1998  

SciTech Connect (OSTI)

This document is the first edition of Argonne`s new Operating Plan. The Operating Plan complements the strategic planning in the Laboratory`s Institutional Plan by focusing on activities that are being pursued in the immediate fiscal year, FY 1998. It reflects planning that has been done to date, and it will serve in the future as a resource and a benchmark for understanding the Laboratory`s performance. The heart of the Institutional Plan is the set of major research initiatives that the Laboratory is proposing to implement in future years. In contrast, this Operating Plan focuses on Argonne`s ongoing R&D programs, along with cost-saving measures and other improvements being implemented in Laboratory support operations.

NONE

1997-10-01T23:59:59.000Z

425

CH Packaging Operations Manual  

SciTech Connect (OSTI)

This procedure provides instructions for assembling the CH Packaging Drum payload assembly, Standard Waste Box (SWB) assembly, Abnormal Operations and ICV and OCV Preshipment Leakage Rate Tests on the packaging seals, using a nondestructive Helium (He) Leak Test.

Washington TRU Solutions LLC

2005-06-13T23:59:59.000Z

426

Cogeneration Operational Issues  

E-Print Network [OSTI]

important, however, are the operational Issues which impact the utility and the cogenerator. This paper addresses the utility perspective in regard to possible impact of cogeneration systems on utility service to other customer, safety and substation...

Williams, M.

427

Idaho Operations Office  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

adverse impacts 40 CFR 1508.27 (b)(l): The selected action establishes a capability to conduct outdoor linac operations at higher power and greater standoff distances. The SOX...

428

Crane Operation Training  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

remove power from the crane and inform the facility management or CAMD safety. Place a lockout tag on the remote control unit. All CAMD crane operations are conducted using the...

429

Plant Operations Executive Director  

E-Print Network [OSTI]

Campus North Campus Recycling Operations Materials Human Resources Payroll Misc Svs Special Projects Planning Spray Shop Glass Shop Upholstery Shop Plant IT Painting Services G. Weincouff Human Resources Business Services Estimating Shutdown Coordination Scheduling L. Rastique Human Resources 67398 M

Awtar, Shorya

430

Corporate Operating Experience Program  

Broader source: Energy.gov [DOE]

The DOE Corporate Operating Experience Program helps to prevent the recurrence of significant adverse events/trends by sharing performance information, lessons learned and good practices across the DOE complex.

431

Essays on Retail Operations  

E-Print Network [OSTI]

-fraction and all-or-none inspection. We further perform a case study to identify deficiencies of store operating practices given different risk preferences. Our findings provide practical guidelines for managers to design cost-efficient inspection policy...

Chuang, Hao-Chun

2013-03-12T23:59:59.000Z

432

Transmission and Storage Operations  

Energy Savers [EERE]

to see minimal to none in static or dynamic mode) - Rates are dependent on size, mechanical wear and operating pressures * PM * PdM 5 Methane Release Reduction Can the gas be...

433

Development of Operation System  

Science Journals Connector (OSTI)

We are gradually developing a total hospital information system known as GUNMAS (Gunma University Network for Medical-Hospital- Information Archiving System). an operation system is also being developed as part o...

Seiji Kato M.D.; Yasuharu Kitani M.D.…

1992-01-01T23:59:59.000Z

434

Pipeline operation and safety  

SciTech Connect (OSTI)

Safety is central to the prosperity of the pipeline industry and the need to maintain high standards of the safety at all times is of paramount importance. Therefore, a primary concern of pipeline operator is adequate supervision and the control of the operation of pipelines. Clearly defined codes of practice, standards and maintenance schedules are necessary if protection is to be afforded to the pipeline system employees, the public at large, and the environment.

Tadors, M.K. [Petroleum Pipelines Co., Cairo (Egypt)

1996-12-31T23:59:59.000Z

435

Document Number Q0029500 Ground Water Model 3.0 Ground Water...  

Office of Legacy Management (LM)

Creek. Each boundary is described under the following headings. U.S. Department of Energy st Grand Junction MMTS OU 111 Remedial Investigation AddendundFacirsed Feasibility...

436

Above-ground antineutrino detection for nuclear reactor monitoring  

Science Journals Connector (OSTI)

Abstract Antineutrino monitoring of nuclear reactors has been demonstrated many times (Klimov et al., 1994 [1]; Bowden et al., 2009 [2]; Oguri et al., 2014 [3]), however the technique has not as of yet been developed into a useful capability for treaty verification purposes. The most notable drawback is the current requirement that detectors be deployed underground, with at least several meters-water-equivalent of shielding from cosmic radiation. In addition, the deployment of liquid-based detection media presents a challenge in reactor facilities. We are currently developing a detector system that has the potential to operate above ground and circumvent deployment problems associated with a liquid detection media: the system is composed of segments of plastic scintillator surrounded by 6LiF/ZnS:Ag. ZnS:Ag is a radio-luminescent phosphor used to detect the neutron capture products of 6Li. Because of its long decay time compared to standard plastic scintillators, pulse-shape discrimination can be used to distinguish positron and neutron interactions resulting from the inverse beta decay (IBD) of antineutrinos within the detector volume, reducing both accidental and correlated backgrounds. Segmentation further reduces backgrounds by identifying the positron?s annihilation gammas, a signature that is absent for most correlated and uncorrelated backgrounds. This work explores different configurations in order to maximize the size of the detector segments without reducing the intrinsic neutron detection efficiency. We believe that this technology will ultimately be applicable to potential safeguards scenarios such as those recently described by Huber et al. (2014) [4,5].

M. Sweany; J. Brennan; B. Cabrera-Palmer; S. Kiff; D. Reyna; D. Throckmorton

2015-01-01T23:59:59.000Z

437

Applicability of Related Data, Algorithms, and Models to the Simulation of Ground-Coupled Residential Hot Water Piping in California  

SciTech Connect (OSTI)

Residential water heating is an important consideration in California?s building energy efficiency standard. Explicit treatment of ground-coupled hot water piping is one of several planned improvements to the standard. The properties of water, piping, insulation, backfill materials, concrete slabs, and soil, their interactions, and their variations with temperature and over time are important considerations in the required supporting analysis. Heat transfer algorithms and models devised for generalized, hot water distribution system, ground-source heat pump and ground heat exchanger, nuclear waste repository, buried oil pipeline, and underground electricity transmission cable applications can be adapted to the simulation of under-slab water piping. A numerical model that permits detailed examination of and broad variations in many inputs while employing a technique to conserve computer run time is recommended.

Warner, J.L.; Lutz, J.D.

2006-01-01T23:59:59.000Z

438

Atlas SCT/Pixel Grounding and Shielding Note 1 ATLAS SCT/Pixel Grounding and Shielding Note  

E-Print Network [OSTI]

Atlas SCT/Pixel Grounding and Shielding Note 1 ATLAS SCT/Pixel Grounding and Shielding Note for SCT. This proposal mostly connects existing mechanical and electrical conductive #12;Atlas SCT. The barrel outer heat shield (150 µm aluminum) is the main element of the shield. #12;Atlas SCT

California at Santa Cruz, University of

439

Remedial Design/Remedial Action Work Plan for Operable Units 6-05 and 10-04, Phase IV  

SciTech Connect (OSTI)

This Phase IV Remedial Design/Remedial Action Work Plan addresses the remediation of areas with the potential for UXO at the Idaho National Laboratory. These areas include portions of the Naval Proving Ground, the Arco High-Altitude Bombing Range, and the Twin Buttes Bombing Range. Five areas within the Naval Proving Ground that are known to contain UXO include the Naval Ordnance Disposal Area, the Mass Detonation Area, the Experimental Field Station, The Rail Car Explosion Area, and the Land Mine Fuze Burn Area. The Phase IV remedial action will be concentrated in these five areas. For other areas, such as the Arco High-Altitude Bombing Range and the Twin Buttes Bombing Range, ordnance has largely consisted of sand-filled practice bombs that do not pose an explosion risk. Ordnance encountered in these areas will be addressed under the Phase I Operations and Maintenance Plan that allows for the recovery and disposal of ordnance that poses an imminent risk to human health or the environment.

R. P. Wells

2006-11-14T23:59:59.000Z

440

(Environmental investigation of ground water contamination at Wright-Patterson Air Force Base, Ohio)  

SciTech Connect (OSTI)

In April 1990, Wright-Patterson Air Force Base (WPAFB), initiated an investigation to evaluate a potential Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) removal action to prevent, to the extent practicable, the offsite migration of contaminated ground water from WPAFB. WPAFB retained the services of the Environmental Management Operations (EMO) and its principle subcontractor, International Technology Corporation (IT) to complete Phase 1 of the environmental investigation of ground-water contamination at WPAFB. Phase 1 of the investigation involves the short-term evaluation and potential design for a program to remove ground-water contamination that appears to be migrating across the western boundary of Area C, and across the northern boundary of Area B along Springfield Pike. Primarily, Task 4 of Phase 1 focuses on collection of information at the Area C and Springfield Pike boundaries of WPAFB. This Sampling and Analysis Plan (SAP) has been prepared to assist in completion of the Task 4 field investigation and is comprised of the Quality Assurance Project Plan (QAPP) and the Field Sampling Plan (FSP).

Not Available

1991-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

BigBOSS: The Ground-Based Stage IV Dark Energy Experiment  

E-Print Network [OSTI]

The BigBOSS experiment is a proposed DOE-NSF Stage IV ground-based dark energy experiment to study baryon acoustic oscillations (BAO) and the growth of structure with an all-sky galaxy redshift survey. The project is designed to unlock the mystery of dark energy using existing ground-based facilities operated by NOAO. A new 4000-fiber R=5000 spectrograph covering a 3-degree diameter field will measure BAO and redshift space distortions in the distribution of galaxies and hydrogen gas spanning redshifts from 0.2merit (DETF FoM) for this experiment is expected to be equal to that of a JDEM mission for BAO with the lower risk and cost typical of a ground-based experiment. This project will enable an unprecedented multi-object spectroscopic capability for the U.S. community through an existing NOAO facility. The U.S. community would have access directly to this instrument/telescope combination, as well as access to the legacy archives that will be created by the ...

Schlegel, David J; Heetderks, Henry; Ho, Shirley; Lampton, Michael; Levi, Michael; Mostek, Nick; Padmanabhan, Nikhil; Perlmutter, Saul; Roe, Natalie; Sholl, Michael; Smoot, George; White, Martin; Dey, Arjun; Abraham, Tony; Jannuzi, Buell; Joyce, Dick; Liang, Ming; Merrill, Mike; Olsen, Knut; Salim, Samir

2009-01-01T23:59:59.000Z

442

Static properties and the Stark effect of the ground state of the HD molecular ion  

Science Journals Connector (OSTI)

We have calculated the static properties of the ground state of the HD+ ion and its lowest-lying P state without making use of the Born-Oppenheimer approximation, as was done in the case of H2+ and D2+ [A. K. Bhatia, Phys. Rev. A 58, 2787 (1998)]. The ion is treated as a three-body system whose ground state is spherically symmetric. The wave function is of generalized Hylleraas type, but it is necessary to include high powers of the internuclear distance to localize the nuclear motion. We obtain good values of the energies of the ground S state and lowest P state and compare them with earlier calculations. Expectation values are obtained for various operators, the Fermi contact parameters, and the permanent quadrupole moment. The cusp conditions are also calculated. The polarizability is then calculated using second-order perturbation theory with intermediate P pseudostates. Since the nuclei in HD+ are not of equal mass there is dipole coupling between the lowest two rotational states, which are almost degenerate. This situation is carefully analyzed, and the Stark shift is calculated variationally as a function of the applied electric field.

A. K. Bhatia and Richard J. Drachman

2000-02-10T23:59:59.000Z

443

Energy San Francisco Operations Office  

Office of Legacy Management (LM)

Depariment of ' Depariment of ' Energy San Francisco Operations Office 1333 Broadway Oakland, California 94612 FEB 6 1984 Mr. c:c. canners Energy Systems Group Rockwell International Corporation Post Office BOX 309 Canoga Park Dear 8 a CA 91304 G ers : Remedial action was taken to decontaminate the Hot Cave (Building 003) and Sodium Reactor Experiment (SRE) under Contract No. DE-AT03-76SF75008. The report of the post remedial survey, performed by Argonne National Laboratory, indicates that the levels of contamination are below the decontamination criteria agreed to between the State of California and DOE/SAN. Based on- this report and the enclosed letter from J. E. Baublitz to Dr. Wynveen, DOE/SAN is releasing for unrestricted use Building 003 and the SRE. Sincerely,

444

STANDARD OPERATING PROTOCOLS FOR DECOMMISSIONING  

SciTech Connect (OSTI)

Decommissioning projects at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites are conducted under project-specific decision documents, which involve extensive preparation time, public comment periods, and regulatory approvals. Often, the decision documents must be initiated at least one year before commencing the decommissioning project, and they are expensive and time consuming to prepare. The Rocky Flats Environmental Technology Site (RFETS) is a former nuclear weapons production plant at which hazardous substances and wastes were released or disposed during operations. As a result of the releases, RFETS was placed on the National Priorities List in 1989, and is conducting cleanup activities under a federal facilities compliance agreement. Working closely with interested stakeholders and state and federal regulatory agencies, RFETS has developed and implemented an improved process for obtaining the approvals. The key to streamlining the approval process has been the development of sitewide decision documents called Rocky Flats Cleanup Agreement Standard Operating Protocols or ''RSOPs.'' RSOPs have broad applicability, and could be used instead of project-specific documents. Although no two decommissioning projects are exactly the same and they may vary widely in contamination and other hazards, the basic steps taken for cleanup are usually similar. Because of this, using RSOPs is more efficient than preparing a separate project-specific decision documents for each cleanup action. Over the Rocky Flats cleanup life cycle, using RSOPs has the potential to: (1) Save over 5 million dollars and 6 months on the site closure schedule; (2) Eliminate preparing one hundred and twenty project-specific decision documents; and (3) Eliminate writing seventy-five closure description documents for hazardous waste unit closure and corrective actions.

Foss, D. L.; Stevens, J. L.; Gerdeman, F. W.

2002-02-25T23:59:59.000Z

445

Multidisciplinary University Research Initiative: High Operating Temperature Fluids  

Broader source: Energy.gov [DOE]

In August 2012, DOE announced two awards under the Multidisciplinary University Research Initiative (MURI) to develop high-operating temperature heat-transfer fluids for concentrating solar power (CSP) applications, managed by the SunShot Initiative.

446

The bunkering industry and its effect on shipping tanker operations  

E-Print Network [OSTI]

The bunkering industry provides the shipping industry with the fuel oil that the vessels consume. The quality of the fuel oil provided will ensure the safe operation of vessels. Shipping companies under their fuel oil ...

Boutsikas, Angelos

2004-01-01T23:59:59.000Z

447

Fast ground-state cooling of mechanical resonators with time-dependent optical cavities  

SciTech Connect (OSTI)

We propose a feasible scheme to cool down a mechanical resonator (MR) in a three-mirror cavity optomechanical system with controllable external optical driving fields. Under the Born-Oppenheimer approximation, the whole dynamics of the mechanical resonator and cavities is reduced to that of a time-dependent harmonic oscillator, whose effective frequency can be controlled through the optical driving fields. The fast cooling of the MR can be realized by controlling the amplitude of the optical driving fields. Significantly, we further show that the ground-state cooling may be achieved via the three-mirror cavity optomechanical system without the resolved sideband condition.

Li Yong [Department of Physics and Center of Theoretical and Computational Physics, University of Hong Kong, Pokfulam Road (Hong Kong); Beijing Computational Science Research Center, Beijing 100084 (China); Wu Lianao [Department of Theoretical Physics and History of Science, The Basque Country University (EHU/UPV), P.O. Box 644, ES-48080 Bilbao (Spain); IKERBASQUE, Basque Foundation for Science, ES-48011 Bilbao (Spain); Wang, Z. D. [Department of Physics and Center of Theoretical and Computational Physics, University of Hong Kong, Pokfulam Road (Hong Kong)

2011-04-15T23:59:59.000Z

448

Ground movements associated with gas hydrate production. Progress report, October 1--December 31, 1992  

SciTech Connect (OSTI)

The grantee will evaluate the influence of hydrate production on ground subsidence near the wellbore and the surface. The objective of this research will be achieved by using computer simulations of what is expected in a hydrate reservoir during the production stage as reported by hydrate production models and available data. The model will be based on theories of continuum mechanics, thermomechanics of hydrate production, principles of rock mechanics and geomechanics, and special features of geomaterials under cold temperatures such as those found in permafrost regions. The research work involved in the proposed investigation will be divided into three major tasks; mechanics of subsidence in permafrost regions, modeling of subsidence, and parametric studies.

Siriwardane, H.J.

1992-12-31T23:59:59.000Z

449

Revised ground-water monitoring compliance plan for the 300 area process trenches  

SciTech Connect (OSTI)

This document contains ground-water monitoring plans for process-water disposal trenches located on the Hanford Site. These trenches, designated the 300 Area Process Trenches, have been used since 1973 for disposal of water that contains small quantities of both chemicals and radionuclides. The ground-water monitoring plans contained herein represent revision and expansion of an effort initiated in June 1985. At that time, a facility-specific monitoring program was implemented at the 300 Area Process Trenches as part of a regulatory compliance effort for hazardous chemicals being conducted on the Hanford Site. This monitoring program was based on the ground-water monitoring requirements for interim-status facilities, which are those facilities that do not yet have final permits, but are authorized to continue interim operations while engaged in the permitting process. The applicable monitoring requirements are described in the Resource Conservation and Recovery Act (RCRA), 40 CFR 265.90 of the federal regulations, and in WAC 173-303-400 of Washington State's regulations (Washington State Department of Ecology 1986). The program implemented for the process trenches was designed to be an alternate program, which is required instead of the standard detection program when a facility is known or suspected to have contaminated the ground water in the uppermost aquifer. The plans for the program, contained in a document prepared by the US Department of Energy (USDOE) in 1985, called for monthly sampling of 14 of the 37 existing monitoring wells at the 300 Area plus the installation and sampling of 2 new wells. 27 refs., 25 figs., 15 tabs.

Schalla, R.; Aaberg, R.L.; Bates, D.J.; Carlile, J.V.M.; Freshley, M.D.; Liikala, T.L.; Mitchell, P.J.; Olsen, K.B.; Rieger, J.T.

1988-09-01T23:59:59.000Z

450

Optical Communication System for Remote Monitoring and Adaptive Control of Distributed Ground Sensors Exhibiting Collective Intelligence  

SciTech Connect (OSTI)

Comprehensive management of the battle-space has created new requirements in information management, communication, and interoperability as they effect surveillance and situational awareness. The objective of this proposal is to expand intelligent controls theory to produce a uniquely powerful implementation of distributed ground-based measurement incorporating both local collective behavior, and interoperative global optimization for sensor fusion and mission oversight. By using a layered hierarchal control architecture to orchestrate adaptive reconfiguration of autonomous robotic agents, we can improve overall robustness and functionality in dynamic tactical environments without information bottlenecks. In this concept, each sensor is equipped with a miniaturized optical reflectance modulator which is interactively monitored as a remote transponder using a covert laser communication protocol from a remote mothership or operative. Robot data-sharing at the ground level can be leveraged with global evaluation criteria, including terrain overlays and remote imaging data. Information sharing and distributed intelli- gence opens up a new class of remote-sensing applications in which small single-function autono- mous observers at the local level can collectively optimize and measure large scale ground-level signals. AS the need for coverage and the number of agents grows to improve spatial resolution, cooperative behavior orchestrated by a global situational awareness umbrella will be an essential ingredient to offset increasing bandwidth requirements within the net. A system of the type described in this proposal will be capable of sensitively detecting, tracking, and mapping spatial distributions of measurement signatures which are non-stationary or obscured by clutter and inter- fering obstacles by virtue of adaptive reconfiguration. This methodology could be used, for example, to field an adaptive ground-penetrating radar for detection of underground structures in urban environments and to detect chemical species concentrations in migrating plumes. Given is our research in these areas and a status report of our progress.

Cameron, S.M.; Stantz, K.M.; Trahan, M.W.; Wagner, J.S.

1998-11-01T23:59:59.000Z

451

Colorado Wind Resource at 50 Meters Above Ground Level  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Wind Resource at 50 Meters Above Ground Level Wind Resource at 50 Meters Above Ground Level Metadata also available as Metadata: Identification_Information Data_Quality_Information Spatial_Data_Organization_Information Spatial_Reference_Information Entity_and_Attribute_Information Distribution_Information Metadata_Reference_Information Identification_Information: Citation: Citation_Information: Originator: AWS TrueWind/NREL Publication_Date: December 2003 Title: Colorado Wind Resource at 50 Meters Above Ground Level Geospatial_Data_Presentation_Form: vector digital data Online_Linkage: Description: Abstract: Annual average wind resource potential for the state of Colorado,

452

Ground Water Protection (North Dakota) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Ground Water Protection (North Dakota) Ground Water Protection (North Dakota) Ground Water Protection (North Dakota) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State North Dakota Program Type Siting and Permitting North Dakota has a degradation prevention program for groundwater protection, with standards established by the Department of Health. This section addresses groundwater standards, quality monitoring, notification

453

Technology, Safety and Costs of Decommissioning a Reference Low-Level Waste Burial Ground Environmental Surveillance Programs  

SciTech Connect (OSTI)

This Addendum supplements, and to some extent replaces, the preliminary description of environmental radiological surveillance programs for low-level waste burial grounds (LLWBG) used in the parent document, 11 Technology, Safety and Costs of DecolliTlissioning a Reference Low-Level Waste Burial Ground, 11 NUREG/ CR-0570. The Addendum provides additional detail and rationale for the environmental radiological surveillance programs for the two referenced sites and inventories described in NUREG/CR-0570. The rationale and performance criteria herein are expected to be useful in providing guidance for determining the acceptability of environmental surveillance programs for other inventories and other LLWBG sites. Two generic burial grounds, one located on an arid western site and the other located on a humid eastern site, are reference facilities considered in this Addendum, and as described in the parent document (NUREG/CR-0570). The two sites are assumed to have the same capacity for waste, the same radioactive waste inventory, and similar trench characteristics and operating procedures. The climate, geology, and hydrology of the two reference sites are typical of existing western and eastern sites, altnough a single population distribution was chosen for both. Each reference burial ground occupies about 70 hectares and includes 180 trenches filled with a total of 1.5 x 10{sup 6} m{sup 3} of radioactive waste. In acldition, there are 10 slit trenches containing about 1.5 x 10{sup 3} m{sup 3} of high beta-gamma activity waste. In this Addendum environmental surveillance programs are described for the several periods in the life of a LLWBG: preoperational (prior to nuclear waste receipt); operational (including interim trench closures); post-operational (after all nuclear waste is received), for both short-term {up to three years) and long-term (up to 100 years) storage and custodial care; and decommissioning (only for the special case of waste removal). The specific environmental monitoring requirements for final site characterization and certification surveys are beyond the scope of this Addendum. Data collection associated with site reconnaissance and preselection is not specifically addressed, but it is recognized that such data may be useful in designing the preoperational program. Predisposal control measures, quality assurance, and record-keeping (other than inventory records) associated with waste disposal operations are also not addressed. The primary intent of routine environmental surveillance at a LLWBG is to help ensure that site activities do not cause significant transport of radioactivity from the site, resulting in an unacceptable health hazard to people. Preoperational environmental surveillance serves to determine for later comparison the background radioactivity levels, either naturally occurring or the result of man's activities (e.g. world-wide fallout or an adjacent nuclear facility), in and around the proposed burial ground site. The operational environmental surveillance program is used to estimate radiological conditions, both onsite and offsite as a possible result of burial ground activities, including trench closure(s). These data help to determine LLWBG compliance with regulatory requirements. During the post-operational period environmental surveillance should normally be an extension of the program carried out during operations, with appropriate deletions (or modifications) to account for the differences between operational and post-operational activities at the site. During the long-term storage and custodial care period, environmental surveillance serves to verify the radionuclide confinement capability of the burial ground and to identify problem situations requiring remedial action. For waste removal (exhumation), the environmental surveillance program is again modified to account for the greatly increased potential for direct radiation and contamination spread. At the time of decommissioning, "environmental surveillance" takes on a new meaning, from that of an ongoing prog

Denham, D. H.; Eddy, P. A.; Hawley, K. A.; Jaquish, R. E.; Corley, J. P.

1981-07-01T23:59:59.000Z

454

Increase of entanglement by local PT -symmetric operations  

E-Print Network [OSTI]

Entanglement plays a central role in the field of quantum information science. It is well known that the degree of entanglement cannot be increased under local operations. Here, we show that the concurrence of a bipartite entangled state can be increased under the local PT -symmetric operation. This violates the property of entanglement monotonicity. We also use the Bell-CHSH and steering inequalities to explore this phenomenon.

Shin-Liang Chen; Guang-Yin Chen; Yueh-Nan Chen

2014-10-17T23:59:59.000Z

455

Operations Information for Studies  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Operations Information for Studies Operations Information for Studies This page contains historical information about hydropower operations. Reclamation UC Region 24-Month Studies FY2009 Load Information (pdf) SLIP total customer loads for Fiscal Year 2009 (Oct, 2008-Sept, 2009) FY2010 Load Information (pdf) SLIP total customer loads for Fiscal Year 2010 (Oct, 2009-Sept, 2010) FY2011 Load Information (pdf) SLIP total customer loads for Fiscal Year 2011 (Oct, 2010-Sept, 2011) FY2012 Load Information (pdf) SLIP total customer loads for Fiscal Year 2012 (Oct, 2011-Sept, 2012) FY2013 Load Information (pdf) SLIP total customer loads for Fiscal Year 2013 (Oct, 2012-Sept, 2013) CRSP Projected Power Releases From USBR (Excel) The most recent file of projected future power releases from CRSP Dams, median projection

456

Storage Ring Operation Modes  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Longitudinal bunch profile and Up: APS Storage Ring Parameters Longitudinal bunch profile and Up: APS Storage Ring Parameters Previous: Source Parameter Table Storage Ring Operation Modes Standard Operating Mode, top-up Fill pattern: 102 mA in 24 singlets (single bunches) with a nominal current of 4.25 mA and a spacing of 153 nanoseconds between singlets. Lattice configuration: Low emittance lattice with effective emittance of 3.1 nm-rad and coupling of 1%. Bunch length (rms): 33.5 ps. Refill schedule: Continuous top-up with single injection pulses occurring at a minimum of two minute intervals, or a multiple of two minute intervals. Special Operating Mode - 324 bunches, non top-up Fill pattern: 102 mA in 324 uniformly spaced singlets with a nominal single bunch current of 0.31 mA and a spacing of 11.37 nanoseconds between singlets.

457

Evidence for ground-water circulation in the brine-filled aquitard, Oak Ridge, Tennessee  

SciTech Connect (OSTI)

Various geologic, hydrologic, and geochemical methods were used to assess active ground-water circulation in a brine-filled, deep (> 50 m below land surface) aquitard underlying the Oak Ridge Reservation, Tennessee. In places, the brine which was presumed to be stagnant in the past, contains various contaminants. If ground-water circulation is viable in the brine-containing formations, then remediation or containment of the deep-seated contaminants should be considered a high priority. Data used to determine this included (1) spatial and temporal pressures and hydraulic heads measured in the aquitard, (2) hydraulic parameters of the formations in question, (3) vertical temperature gradients, and (4) spatial and temporal chemical and isotopic composition of the saline ground water. Conclusions suggest that the saline water contained at depth is not isolated (in terms of recharge and discharge) from the overlying active and fresh-water-(< 500 mg/l) bearing units. Consequently, influx of young water (and contamination) from land surface does occur. Potential discharge into the shallow aquifers was assumed where the hydraulic head of the saline water was higher than that in the shallow aquifers, accounting for temperature and salinity anomalies observed close to land surface. The confined water (and dissolved solutes) move along open conduits at relatively high velocity into adjacent, more permeable units.

Nativ, R. [Hebrew Univ. of Jerusalem (Israel). Dept. of Soil and Water Sciences; Halleran, A.; Hunley, A. [Oak Ridge National Lab., TN (United States). Environmental Sciences Div.

1997-07-01T23:59:59.000Z

458

Testing sand used in hydraulic fracturing operations  

SciTech Connect (OSTI)

Recommended practices for testing sand used in hydraulic fracturing operations are outlined as developed by the Task Group on Evaluation of Hydraulic Fracturing Sand under the API Subcommittee on Evaluation of Well Completion Materials. The tests recommended were developed to improve the quality of frac sand delivered to the well site, and are for use in evaluating certain physical properties of sand used in hydraulic fracturing operations. The tests suggested enable users to compare physical characteristics of various sands and to select materials most useful for such applications. Parameters to be tested include turbidity, clay and soft particle content, crush resistance, and mineralogic analysis.

Not Available

1983-03-01T23:59:59.000Z

459

Visualizing operators of coupled spin systems  

E-Print Network [OSTI]

The state of quantum systems, their energetics, and their time evolution is modeled by abstract operators. How can one visualize such operators for coupled spin systems? A general approach is presented which consists of several shapes representing linear combinations of spherical harmonics. It is applicable to an arbitrary number of spins and can be interpreted as a generalization of Wigner functions. The corresponding visualization transforms naturally under non-selective spin rotations as well as spin permutations. Examples and applications are illustrated for the case of three spins 1/2.

Ariane Garon; Robert Zeier; Steffen J. Glaser

2014-09-18T23:59:59.000Z

460

Updated July 2009 Operations Organization  

E-Print Network [OSTI]

All-Hands, Brown Bags, and COO Open-Door sessions Ongoing Conduct Operations Employee Climate SurveysOperations Strategic Plan Updated July 2009 #12;Operations Organization Chief Operating Officer deliver exceptional operational services in support of the scientific mission of Berkeley Lab. goals

Eisen, Michael

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Facility Operations | Department of Energy  

Office of Environmental Management (EM)

e-mail GTNFacOpsHelpdesk@hq.doe.gov Grounds and Elevator Maintenance Heating and Air Conditioning Inquiries regarding heating and air conditioning should be made to the...

462

Ground magnetic survey in the Coso Range, California | Open Energy  

Open Energy Info (EERE)

Ground magnetic survey in the Coso Range, California Ground magnetic survey in the Coso Range, California Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Ground magnetic survey in the Coso Range, California Details Activities (1) Areas (1) Regions (0) Abstract: A ground magnetic study was completed in the Coso volcanic field to investigate faulting and associated hydrothermal alteration patterns. The magnetic intensity contours match general geologic patterns in varying rock types. Hydrothermally altered rocks along intersecting fault zones show up as strong magnetic lows that form a triangular-shaped area. This area is centered in an area of highest heat flow and is a site of concentrated fumarolic activity. In the Coso volcanic field the combination of high heat flow, fumarolic activity, magnetic lows, and hydrothermal

463

SB Electronics Breaks Ground on New Factory | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

SB Electronics Breaks Ground on New Factory SB Electronics Breaks Ground on New Factory SB Electronics Breaks Ground on New Factory April 29, 2010 - 5:22pm Addthis U.S. Rep. Peter Welch (from left), Vermont Lt. Gov. Brian Dubie, SBE board member Win Hunter, SBE board chair Stan Fishkin, Assi U.S. Rep. Peter Welch (from left), Vermont Lt. Gov. Brian Dubie, SBE board member Win Hunter, SBE board chair Stan Fishkin, Assi Paul Lester Communications Specialist, Office of Energy Efficiency and Renewable Energy A Vermont company broke ground on a new factory that will produce cutting-edge technology for electric and hybrid cars and create more than 100 jobs. The event ushering in SB Electronics' power ring capacitor facility in Barre was attended by Vermont Gov. Jim Douglas and federal, state and local

464

Breaking Ground in Miami-Dade | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Breaking Ground in Miami-Dade Breaking Ground in Miami-Dade Breaking Ground in Miami-Dade October 15, 2010 - 4:28pm Addthis Existing Miami-Dade county water treatment facility. Existing Miami-Dade county water treatment facility. Andy Oare Andy Oare Former New Media Strategist, Office of Public Affairs Officials from Miami-Dade County and the U.S. Department of Energy were on hand Wednesday, October 13th to formally break ground on an innovative project that will help improve the energy efficiency of one of the county's major water treatment facilities. The project will upgrade and expand the existing power generation system at the water plant which generates electricity from digester gas produced at the plant. Landfill gas, which is produced from the Solid Waste Department's South Dade Landfill, will be collected and piped across a

465

Digging Begins at Hazardous Hanford Burial Ground - River Corridor  

Broader source: Energy.gov (indexed) [DOE]

Digging Begins at Hazardous Hanford Burial Ground - River Corridor Digging Begins at Hazardous Hanford Burial Ground - River Corridor Contractor Spent Two Years Preparing to Remediate 618-10 Digging Begins at Hazardous Hanford Burial Ground - River Corridor Contractor Spent Two Years Preparing to Remediate 618-10 August 3, 2011 - 12:00pm Addthis Media Contacts Cameron Hardy, DOE Cameron.Hardy@rl.doe.gov 509-376-5365 Todd Nelson, Washington Closure media@wch-rcc.com 509-372-9097 RICHLAND, WASH. - After careful preparation and characterization, the Department of Energy's (DOE) River Corridor contractor, Washington Closure Hanford, has begun remediation of one of the most hazardous burial grounds tackled to date on the Hanford Site's River Corridor. The $57 million American Recovery and Reinvestment Act project began with nearly two years of preparation and characterization before reaching their

466

411 / 2011 / 01 fp Grounds RFP v6  

E-Print Network [OSTI]

OF THE UNIVERSITY'S GROUNDS AND OUTDOOR SPORTS FACILITIES MAINTENANCE AND RELATED ANCILLARY AND COMPLEMENTARY....................................................................................... 5 2.4. MAINTENANCE CONTRACT one or more suitably qualified and experienced landscape and turf grass contractors to manage

467

A Stochastic Ground?Motion Model for Switzerland  

Science Journals Connector (OSTI)

...Rietbrock, 2009) stress parameters. Figure 9. Aerial view of fault and simulation directions. Note in...Irikura, H. K. Thio, P. G. Somerville, Y. Fukushima, and Y. Fukushima (2006). Attenuation relations of strong ground...

Benjamin Edwards; Donat Fäh

468

A roughening transition indicated by the behaviour of ground states  

E-Print Network [OSTI]

We present some illustrations for the claim that already by looking at the ground states of classical lattice models, one may meet some interesting and non-trivial structures.

Salvador Miracle-Sole

2012-06-17T23:59:59.000Z

469

Effectiveness of aquamag ground brucite in water treatment processes  

Science Journals Connector (OSTI)

We present the results of laboratory tests of the physical and chemical properties of two size fractions of Aquamag ground brucite (particle sizes 0–45 µm and ... acid), as well as the effectiveness of brucite fo...

A. N. Belevtsev; S. A. Baikova; V. I. Zhavoronkova; N. N. Mel’nikova…

2007-05-01T23:59:59.000Z

470

Combined permeable pavement and ground source heat pump systems   

E-Print Network [OSTI]

The PhD thesis focuses on the performance assessment of permeable pavement systems incorporating ground source heat pumps (GSHP). The relatively high variability of temperature in these systems allows for the survival of pathogenic organisms within...

Grabowiecki, Piotr

2010-01-01T23:59:59.000Z

471

Optimal Design for a Hybrid Ground-Source Heat Pump  

E-Print Network [OSTI]

Although the advantages of ground-source heat pumps over their conventional alternatives make these systems a very attractive choice for air conditioning, not only for residential buildings but increasingly also for institutional and commercial...

Yu, Z.; Yuan, X.; Wang, B.

2006-01-01T23:59:59.000Z

472

Effect of ground corn steeping on starch properties  

Science Journals Connector (OSTI)

Pasting and thermal properties, and microstructure of starch from ground corn (GS) steeped at 52 °C in ... were investigated. The isolated starch obtained by wet milling was characterised by determining pasting p...

Monica Haros; Wioletta Blaszczak; Oscar E. Perez…

2006-01-01T23:59:59.000Z

473

Control and waypoint navigation of an autonomous ground vehicle  

E-Print Network [OSTI]

This thesis describes the initial development of the Texas A&M Autonomous Ground Vehicle test platform and waypoint following software, including the associated controller design. The original goal of the team responsible for the development...

Massey, James Patrick

2006-08-16T23:59:59.000Z

474

Improvable upper bounds to the piezoelectric polaron ground state energy  

E-Print Network [OSTI]

It was shown that an infinite sequence of improving non-increasing upper bounds to the ground state energy (GSE) of a slow-moving piezoeletric polaron can be devised.

A. V. Soldatov

2014-12-31T23:59:59.000Z

475

EPA Final Ground Water Rule Available Online, 3/07  

Broader source: Energy.gov [DOE]

On November 8, 2006, the U.S. Environmental Protection Agency (EPA) published a final Ground Water Rule (GWR) to promote increased protection against microbial pathogens that may be present in...

476

Natural Remediation Potential of Arsenic-Contaminated Ground Water  

Science Journals Connector (OSTI)

Migration of leachate from a municipal landfill in Saco, Maine has resulted in arsenic concentrations in ground water as high as 647 ?g/L.... Laboratory experimental data indicate the primary source of arsenic to...

Kenneth G. Stollenwerk; John A. Colman

2003-01-01T23:59:59.000Z

477

Remedial Costs for MTBE in Soil and Ground Water  

Science Journals Connector (OSTI)

The contamination of MTBE in ground water has introduced concerns about the increased cost of remediating MTBE/BTEX releases compared to remediating sites with BTEX only contamination. In an attempt to evaluat...

Barbara H. Wilson; John T. Wilson Ph.D.

2003-01-01T23:59:59.000Z

478

Analysis of Ground-Water Remediation During a Pesticide Application  

Science Journals Connector (OSTI)

Pesticides are widely used in the pest management. More than one hundred pesticides and their degradation products have been identified as potential ground-water contaminants (Miles, 1992) and many of these pe...

Richard Tykva

1996-01-01T23:59:59.000Z

479

Preparation and probing of the ground state coherence in Rubidium  

E-Print Network [OSTI]

We demonstrate the preparation and probing of the coherence between the hyperfine ground states |5S_{1/2}, F=1> and |5S_{1/2}, F=2> of the Rubidium 87 isotope. The effect of various coherence control techniques, i.e. fractional Stimulated Raman Adiabatic Passage and Coherent Population Return on the coherence are investigated. These techniques are implemented using nearly degenerate pump and Stokes lasers at 795nm (Rubidium D1 transition) which couple the two hyperfine ground states via the excited state |5P_{1/2}, F=1> through a resonant two-photon process, in which a coherent superposition of the two hyperfine ground states is established. The medium is probed by an additional weak laser, which generates a four-wave mixing signal proportional to the ground state coherence, and allows us to monitor its evolution in time. The experimental data are compared with numerical simulations.

Martin Oberst; Frank Vewinger; A. I. Lvovsky

2007-01-31T23:59:59.000Z

480

Mk12A/W78 ground test project (u)  

SciTech Connect (OSTI)

The slides present the scope, objectives and status of the Mk12A1W78 Ground Test Project for the purpose of updating the ICBM Project Officers Group. In addition, project constraints and risks are discussed.

Stokes, Kyle R [Los Alamos National Laboratory

2010-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "operate under ground" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

LWDA Ground Screen Performance Report July 23, 2007  

E-Print Network [OSTI]

is in the notching and maneuvering of the wire underneath the antenna. The weather on the day of installation ranged the antenna. The metrics of interest are total antenna loss (due mismatch and ground losses) for a given

Ellingson, Steven W.

482

Ground facilities for a VTOL intercity air transportation system  

E-Print Network [OSTI]

Introduction: This study covers the design of ground facilities, or metroports, for a future form of short haul intercity air transportation, the VTOL Airbus system as described by previous M.I.T. Flight Transportation ...

Allen Edward

1970-01-01T23:59:59.000Z

483

Ground Breaking of Blythe Solar Power Project | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Ground Breaking of Blythe Solar Power Project Ground Breaking of Blythe Solar Power Project Ground Breaking of Blythe Solar Power Project June 20, 2011 - 2:16pm Addthis Secretary Chu Secretary Chu Former Secretary of Energy What will the project do? Blythe Solar Power Project will generate 1,000 megawatts of solar power, enough to power more than 300,000 single-family homes a year. Back in April, I had the pleasure of announcing that the Department of Energy had extended our largest conditional loan guarantee for a solar project - $2.1 billion to support a concentrating solar thermal power plant near Blythe, California. Last Friday, the Blythe Solar Power Project broke ground, beginning construction of a project that upon completion will generate 1,000 megawatts of solar power, enough to power more than 300,000

484

Ground states of lattice gases with ``almost'' convex repulsive interactions  

E-Print Network [OSTI]

the feature known as the complete devil's staircase. KEY WORDS: Classical lattice­gas models; ground states; nonconvex interactions; most homogeneous configurations; devil's staircase. \\Lambda Pl. Maksa Borna 9, 50

485

Universal patterns underlying ongoing wars and terrorism  

E-Print Network [OSTI]

We report a remarkable universality in the patterns of violence arising in three high-profile ongoing wars, and in global terrorism. Our results suggest that these quite different conflict arenas currently feature a common type of enemy, i.e. the various insurgent forces are beginning to operate in a similar way regardless of their underlying ideologies, motivations and the terrain in which they operate. We provide a microscopic theory to explain our main observations. This theory treats the insurgent force as a generic, self-organizing system which is dynamically evolving through the continual coalescence and fragmentation of its constituent groups.

Johnson, N F; Restrepo, J A; Becerra, O; Bohorquez, J C; Suárez, N; Restrepo, E M; Zarama, R; Johnson, Neil F.; Spagat, Mike; Restrepo, Jorge A.; Becerra, Oscar; Bohorquez, Juan Camilo; Suarez, Nicolas; Restrepo, Elvira Maria; Zarama, Roberto

2006-01-01T23:59:59.000Z

486

Project Profile: High Operating Temperature Liquid Metal Heat Transfer Fluids  

Broader source: Energy.gov [DOE]

The University of California, Los Angeles (UCLA), along with partners at the University of California, Berkeley, and Yale University, under the 2012 Multidisciplinary University Research Initiative (MURI): High Operating Temperature (HOT) Fluids funding opportunity, is investigating the use of metal alloys as a heat transfer fluid (HTF) in concentrating solar power (CSP) systems operating at temperatures in excess of 800°C. By allowing higher temperature operation, CSP systems can achieve greater efficiencies and thereby reduce the overall cost of electricity production.

487

Development of Optimization Tool for Air Conditioning System Operation  

E-Print Network [OSTI]

Operations, Berlin, Germany, October 20-22, 2008 Outside air temperature and the absolute air humidity are predicted by the Auto-regressive Integrated Moving Average (ARIMA) model [1],[2]. The solar radiation on a horizontal surface... of the error margin Energy Consumption (set value A) Energy Consumption (set value B) ESL-IC-08-10-55 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 J VAV unit is also operated under...

Sumiyoshi, D.; Akashi, Y.

488

Hoyte Phifer Facilities Operations  

E-Print Network [OSTI]

battery operated clocks in offices. #12;#12;·Last year, UNCG produced over 1973 tons of solid waste. · 1. , corner of Highland Ave. and Oakland ­ red brick building #12;#12; "All State agencies, universities, and community colleges that have State-owned vehicle fleets shall develop and implement plans to improve

Saidak, Filip

489

Concept of Operations: Essence  

SciTech Connect (OSTI)

This concept of operations is designed to give the reader a brief overview of the National Rural Electric Cooperative Association’s Essence project and a description of the Essence device design. The data collected by the device, how the data are used, and how the data are protected are also discussed in this document.

Hutton, William J.

2014-04-01T23:59:59.000Z

490

Conduct of Operations  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Order defines the requirements for establishing and implementing Conduct of Operations Programs at Department of Energy (DOE), including National Nuclear Security Administration (NNSA), facilities and projects. Cancels DOE O 5480.19. Admin Chg 2, dated 12-3-14, cancels Admin Chg 1.

2010-06-29T23:59:59.000Z

491

RUNWAY OPERATIONAL QUALITY ASSURANCE  

E-Print Network [OSTI]

RUNWAY OPERATIONAL QUALITY ASSURANCE MELANIE BAKER, DARIC MEGERSA & ALFONSO PANLILIO Sponsors: Dr Vortex Separation Rule, for a homogeneous fleet mix, is determined by the time between arriving aircraft Occupancy (SRO) rule, for a non- homogeneous fleet mix, MTC= 3600/ [ROT] [ROT]= = i (pi *ROTi) ROT (in sec

492

Protection of ground and surface waters, January 1982-August 1987: Citations from AGRICOLA (Agricultural Online Access) concerning diseases and other environmental considerations. Final report  

SciTech Connect (OSTI)

The citations in this bibliography are selected from English-language material from the international literature on the agricultural aspects of the pollution of ground and surface water by chemicals. Some of the subject areas include: Agricultural operations; Pesticides; Legislation; Land use; Urban hydrology and pollution; Food processing wastes; and Waste treatment.

Bebee, C.N.

1987-07-01T23:59:59.000Z

493

Ground Source Integrated Heat Pump (GS-IHP) Development  

SciTech Connect (OSTI)

Between October 2008 and May 2013 ORNL and ClimateMaster, Inc. (CM) engaged in a Cooperative Research and Development Agreement (CRADA) to develop a groundsource integrated heat pump (GS-IHP) system for the US residential market. A initial prototype was designed and fabricated, lab-tested, and modeled in TRNSYS (SOLAR Energy Laboratory, et al, 2010) to predict annual performance relative to 1) a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of air-source heat pump (ASHP) and resistance water heater) and 2) a state-of-the-art (SOA) two-capacity ground-source heat pump with desuperheater water heater (WH) option (GSHPwDS). Predicted total annual energy savings, while providing space conditioning and water heating for a 2600 ft{sup 2} (242 m{sup 2}) house at 5 U.S. locations, ranged from 52 to 59%, averaging 55%, relative to the minimum efficiency suite. Predicted energy use for water heating was reduced 68 to 78% relative to resistance WH. Predicted total annual savings for the GSHPwDS relative to the same baseline averaged 22.6% with water heating energy use reduced by 10 to 30% from desuperheater contributions. The 1st generation (or alpha) prototype design for the GS-IHP was finalized in 2010 and field test samples were fabricated for testing by CM and by ORNL. Two of the alpha units were installed in 3700 ft{sup 2} (345 m{sup 2}) houses at the ZEBRAlliance site in Oak Ridge and field tested during 2011. Based on the steady-state performance demonstrated by the GS-IHPs it was projected that it would achieve >52% energy savings relative to the minimum efficiency suite at this specific site. A number of operational issues with the alpha units were identified indicating design changes needed to the system before market introduction could be accomplished. These were communicated to CM throughout the field test period. Based on the alpha unit test results and the diagnostic information coming from the field test experience, CM developed a 2nd generation (or beta) prototype in 2012. Field test verification units were fabricated and installed at the ZEBRAlliance site in Oak Ridge in May 2012 and at several sites near CM headquarters in Oklahoma. Field testing of the units continued through February 2013. Annual performance analyses of the beta unit (prototype 2) with vertical well ground heat exchangers (GHX) in 5 U.S. locations predict annual energy savings of 57% to 61%, averaging 59% relative to the minimum efficiency suite and 38% to 56%, averaging 46% relative to the SOA GSHPwDS. Based on the steady-state performance demonstrated by the test units it was projected that the 2nd generation units would achieve ~58% energy savings relative to the minimum efficiency suite at the Zebra Alliance site with horizontal GHX. A new product based on the beta unit design was announced by CM in 2012 – the Trilogy 40® Q-mode™ (http://cmdealernet.com/trilogy_40.html). The unit was formally introduced in a March 2012 press release (see Appendix A) and was available for order beginning in December 2012.

Baxter, V. D. [ORNL; Rice, K. [ORNL; Murphy, R. [ORNL; Munk, J. [ORNL; Ally, Moonis [ORNL; Shen, Bo [ORNL; Craddick, William [ORNL; Hearn, Shawn A. [ClimateMaster, Inc.

2013-05-24T23:59:59.000Z

494

Ground state hyperfine structure in muonic lithium ions  

E-Print Network [OSTI]

On the basis of perturbation theory in fine structure constant alpha and the ratio of electron to muon masses we calculate one-loop vacuum polarization, electron vertex corrections, nuclear structure and recoil corrections to hyperfine splitting of the ground state in muonic lithium ions $(\\mu\\ e\\ ^6_3Li)^+$ and $(\\mu\\ e\\ ^7_3Li)^+$. We obtain total results for the ground state small hyperfine splittings in $(\\mu\\ e\\ ^6_3Li)^+$ $\\Delta\

Martynenko, A P

2014-01-01T23:59:59.000Z

495

Ground state hyperfine structure in muonic lithium ions  

E-Print Network [OSTI]

On the basis of perturbation theory in fine structure constant alpha and the ratio of electron to muon masses we calculate one-loop vacuum polarization, electron vertex corrections, nuclear structure and recoil corrections to hyperfine splitting of the ground state in muonic lithium ions $(\\mu\\ e\\ ^6_3Li)^+$ and $(\\mu\\ e\\ ^7_3Li)^+$. We obtain total results for the ground state small hyperfine splittings in $(\\mu\\ e\\ ^6_3Li)^+$ $\\Delta\

A. P. Martynenko; A. A. Ulybin

2014-11-12T23:59:59.000Z

496

Emergency Operations Training Academy | National Nuclear Security...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Emergency Operations Training Academy Emergency Operations Training Academy Emergency Operations Training Academy The Office of Emergency Operations, NA-40-The Emergency Operations...

497

CRAD, Conduct of Operations - Y-12 Enriched Uranium Operations Oxide  

Broader source: Energy.gov (indexed) [DOE]

Conduct of Operations - Y-12 Enriched Uranium Operations Conduct of Operations - Y-12 Enriched Uranium Operations Oxide Conversion Facility CRAD, Conduct of Operations - Y-12 Enriched Uranium Operations Oxide Conversion Facility January 2005 A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for a January, 2005 assessment of Conduct of Operations program at the Y-12 - Enriched Uranium Operations Oxide Conversion Facility. CRADs provide a recommended approach and the types of information to gather to assess elements of a DOE contractor's programs. CRAD, Conduct of Operations - Y-12 Enriched Uranium Operations Oxide Conversion Facility More Documents & Publications CRAD, DOE Oversight - Y-12 Enriched Uranium Operations Oxide Conversion

498

A Review of Ground Coupled Heat Pump Models Used in Whole-Building Computer Simulation Programs  

E-Print Network [OSTI]

Increasingly, building owners are turning to ground source heat pump (GSHP) systems to improve energy efficiency. Ground-coupled heat pump (GCHP) systems with a vertical closed ground loop heat exchanger are one of the more widely used systems. Over...

Do, S. L.; Haberl, J. S.

499

Cable Measuring Engine Operation Procedures  

E-Print Network [OSTI]

MEASURING ENGINE OPERATION PROCEDURES LBNL-40565 SC-MAG-597MEASURING ENGINE OPERATION PROCEDURES INDEX IN T ROD U C TCALIBRATION PROCEDURE . .

Authors, Various

2011-01-01T23:59:59.000Z

500

Operations and Maintenance Program Structure  

Broader source: Energy.gov [DOE]

The Federal Energy Management Program recommends Federal operations and maintenance (O&M) programs comprise of five distinct functions: operations, maintenance, engineering, training, and...