National Library of Energy BETA

Sample records for non-networked single station

  1. FIBER-OPTIC BUS-ORIENTED SINGLE-HOP INTERCONNECTIONS AMONG MULTI-TRANSCEIVER STATIONS

    E-Print Network [OSTI]

    ,ooffer substantial advantages in power budget and the maximum number of stations that can be interconnected withoutFIBER-OPTIC BUS-ORIENTED SINGLE-HOP INTERCONNECTIONS AMONG MULTI-TRANSCEIVER STATIONS Yitzhak Birk among a set of stations, each equipped with multiple, say c, transmitters and receivers. It employs cz

  2. E cient Layout of a Passive, Single-Hop, Fiber-Optic Interconnection (among N stations)

    E-Print Network [OSTI]

    E cient Layout of a Passive, Single-Hop, Fiber-Optic Interconnection (among N stations-hop, ber-optic interconnection among n stations, each with two trans- mitters and one receiver, and a round, but the layout of this interconnection poses a challenge both in terms of wiring complex- ity and power budget

  3. Station for X-ray structural analysis of materials and single crystals (including nanocrystals) on a synchrotron radiation beam from the wiggler at the Siberia-2 storage ring

    SciTech Connect (OSTI)

    Kheiker, D. M. Kovalchuk, M. V.; Korchuganov, V. N.; Shilin, Yu. N.; Shishkov, V. A.; Sulyanov, S. N.; Dorovatovskii, P. V.; Rubinsky, S. V.; Rusakov, A. A.

    2007-11-15

    The design of the station for structural analysis of polycrystalline materials and single crystals (including nanoobjects and macromolecular crystals) on a synchrotron radiation beam from the superconducting wiggler of the Siberia-2 storage ring is described. The wiggler is constructed at the Budker Institute of Nuclear Physics of the Siberian Division of the Russian Academy of Sciences. The X-ray optical scheme of the station involves a (1, -1) double-crystal monochromator with a fixed position of the monochromatic beam and a sagittal bending of the second crystal, segmented mirrors bent by piezoelectric motors, and a (2{theta}, {omega}, {phi}) three-circle goniometer with a fixed tilt angle. Almost all devices of the station are designed and fabricated at the Shubnikov Institute of Crystallography of the Russian Academy of Sciences. The Bruker APEX11 two-dimensional CCD detector will serve as a detector in the station.

  4. M Station, Austin 

    E-Print Network [OSTI]

    Mathon, S.

    2011-01-01

    $300 ID LL SS WE EA MR EQ AE LEED Platinum (Standard) 90 ID LL SS WE EA MR EQ AE LEED Platinum (Standard) LEED Platinum (M Station) 9081 ID LL SS WE EA MR EQ AE LEED Platinum (Standard) LEED Platinum (M Station) M Station 9081 108 ID LL... SS WE EA MR EQ AE LEED Platinum (Standard) LEED Platinum (M Station) M Station 9081 10849 $0.00/sf Planning ID LL SS WE EA MR EQ AE LEED Platinum (Standard) LEED Platinum (M Station) M Station 9081 10849 $0.00/sf Planning Location ID...

  5. Single transmission line interrogated multiple channel data acquisition system

    DOE Patents [OSTI]

    Fasching, George E. (Morgantown, WV); Keech, Jr., Thomas W. (Morgantown, WV)

    1980-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensor circuits each monitors a specific process variable and each transmits measurement values over a single transmission line to a master interrogating station when addressed by said master interrogating station. Typically, as many as 330 remote stations may be parallel connected to the transmission line which may exceed 7,000 feet. The interrogation rate is typically 330 stations/second. The master interrogating station samples each station according to a shared, charging transmit-receive cycle. All remote station address signals, all data signals from the remote stations/sensors and all power for all of the remote station/sensors are transmitted via a single continuous terminated coaxial cable. A means is provided for periodically and remotely calibrating all remote sensors for zero and span. A provision is available to remotely disconnect any selected sensor station from the main transmission line.

  6. Single transmission line data acquisition system

    DOE Patents [OSTI]

    Fasching, George E. (Morgantown, WV)

    1984-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

  7. Hydrogen Filling Station

    SciTech Connect (OSTI)

    Boehm, Robert F; Sabacky, Bruce; Anderson II, Everett B; Haberman, David; Al-Hassin, Mowafak; He, Xiaoming; Morriseau, Brian

    2010-02-24

    Hydrogen is an environmentally attractive transportation fuel that has the potential to displace fossil fuels. The Freedom CAR and Freedom FUEL initiatives emphasize the importance of hydrogen as a future transportation fuel. Presently, Las Vegas has one hydrogen fueling station powered by natural gas. However, the use of traditional sources of energy to produce hydrogen does not maximize the benefit. The hydrogen fueling station developed under this grant used electrolysis units and solar energy to produce hydrogen fuel. Water and electricity are furnished to the unit and the output is hydrogen and oxygen. Three vehicles were converted to utilize the hydrogen produced at the station. The vehicles were all equipped with different types of technologies. The vehicles were used in the day-to-day operation of the Las Vegas Valley Water District and monitoring was performed on efficiency, reliability and maintenance requirements. The research and demonstration utilized for the reconfiguration of these vehicles could lead to new technologies in vehicle development that could make hydrogen-fueled vehicles more cost effective, economical, efficient and more widely used. In order to advance the development of a hydrogen future in Southern Nevada, project partners recognized a need to bring various entities involved in hydrogen development and deployment together as a means of sharing knowledge and eliminating duplication of efforts. A road-mapping session was held in Las Vegas in June 2006. The Nevada State Energy Office, representatives from DOE, DOE contractors and LANL, NETL, NREL were present. Leadership from the National hydrogen Association Board of Directors also attended. As a result of this session, a roadmap for hydrogen development was created. This roadmap has the ability to become a tool for use by other road-mapping efforts in the hydrogen community. It could also become a standard template for other states or even countries to approach planning for a hydrogen future. Project partners also conducted a workshop on hydrogen safety and permitting. This provided an opportunity for the various permitting agencies and end users to gather to share experiences and knowledge. As a result of this workshop, the permitting process for the hydrogen filling station on the Las Vegas Valley Water District’s land was done more efficiently and those who would be responsible for the operation were better educated on the safety and reliability of hydrogen production and storage. The lessons learned in permitting the filling station and conducting this workshop provided a basis for future hydrogen projects in the region. Continuing efforts to increase the working pressure of electrolysis and efficiency have been pursued. Research was also performed on improving the cost, efficiency and durability of Proton Exchange Membrane (PEM) hydrogen technology. Research elements focused upon PEM membranes, electrodes/catalysts, membrane-electrode assemblies, seals, bipolar plates, utilization of renewable power, reliability issues, scale, and advanced conversion topics. Additionally, direct solar-to-hydrogen conversion research to demonstrate stable and efficient photoelectrochemistry (PEC) hydrogen production systems based on a number of optional concepts was performed. Candidate PEC concepts included technical obstacles such as inefficient photocatalysis, inadequate photocurrent due to non-optimal material band gap energies, rapid electron-hole recombination, reduced hole mobility and diminished operational lifetimes of surface materials exposed to electrolytes. Project Objective 1: Design, build, operate hydrogen filling station Project Objective 2: Perform research and development for utilizing solar technologies on the hydrogen filling station and convert two utility vehicles for use by the station operators Project Objective 3: Increase capacity of hydrogen filling station; add additional vehicle; conduct safety workshop; develop a roadmap for hydrogen development; accelerate the development of photovoltaic components Project Objective 4:

  8. Strawberries at Troupe Station

    E-Print Network [OSTI]

    Green, Edward C.

    1904-01-01

    THE TEXAS A&M UNIVERSITY SYSTEM DANIEL C. PFANNSTIEL, DIRECTOR COLLEGE STATION, TEXAS I COVER Kenneth Hoffman, Extension demonstrator, and Hollis Duke, Atascosa County Extension agent, inspect a field of Fresno strawberries in Poteet. as Strawberries... George Ray McEachern and Bluefford G. Hancock* ery vigorous plant and can r a wide range of conditions. However, a profitable crop, definite practices are strawberry plant has three basic parts-tlle wn, and leaves. The roots are shallow and rbing...

  9. Transit Infrastructure Finance Through Station Location Auctions

    E-Print Network [OSTI]

    Ian Carlton

    2009-01-01

    Numerous route and station options Strong real estate marketreal estate market Transit friendly constituents Numerous route and station options

  10. Oriel UV Exposure Station

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration wouldMass mapSpeeding access toOctoberConsumption (Million CubicLSDOriel UV Exposure Station

  11. UIC/HALSTED CTA STATION

    E-Print Network [OSTI]

    Illinois at Chicago, University of

    UIC/HALSTED CTA STATION TAYLOR STREET ROOSEVELT ROAD POLK STREET MILLERSTREET CARPENTERSTREET VERNON PARK HARRISON STREET EISENHOWER EXPRESSWAY I-290 DANRYANEXPRESSWAYI-90/94 POLK STREET MORGANSTREET

  12. PacificSouthwestResearchStationPrograms Pacific Southwest Research Station

    E-Print Network [OSTI]

    PacificSouthwestResearchStationPrograms Pacific Southwest Research Station Publications List Air Pollution and Global Change Impacts on Western Forest Ecosystems Center for Urban Forest Research Chemical branch of the USDA Forest Service in the states of California and Hawaii and the U.S.-affiliat- ed

  13. Alan a. Blggs Agriculture Canada, Research Station, Vineland Station, Ontario

    E-Print Network [OSTI]

    Biggs, Alan R.

    Alan a. Blggs Agriculture Canada, Research Station, Vineland Station, Ontario IntegratedApproach to Controlling LeucostomaCankerof Peachin Ontario Peach (Prunuspersica (L.) Batsch) is the third most valuable fruit crop in Ontario, Canada, following appIes (Matus domestica Barkh.) and grapes (Vizisspp.). In 1988

  14. Energy Department Launches Alternative Fueling Station Locator...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Launches Alternative Fueling Station Locator App Energy Department Launches Alternative Fueling Station Locator App November 7, 2013 - 11:16am Addthis As part of the Obama...

  15. Hydrogen Refueling Station Costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, Joan M; Jianxin, Ma

    2006-01-01

    04 Hydrogen Refueling Station Costs in Shanghai Jonathan X.Hydrogen Refueling Station Costs in Shanghai Jonathan X.voltage connections) Capital costs for this equipment must

  16. Hydrogen refueling station costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, Joan M; Jianxin, Ma

    2007-01-01

    Kingdom; 2004. [8] Amos W. Costs of storing and transportingcon- nections). Capital costs for this equipment must bein an analysis of station costs. Total station construction

  17. Robust bearing estimation for 3-component stations

    SciTech Connect (OSTI)

    CLAASSEN,JOHN P.

    2000-02-01

    A robust bearing estimation process for 3-component stations has been developed and explored. The method, called SEEC for Search, Estimate, Evaluate and Correct, intelligently exploits the inherent information in the arrival at every step of the process to achieve near-optimal results. In particular the approach uses a consistent framework to define the optimal time-frequency windows on which to make estimates, to make the bearing estimates themselves, to construct metrics helpful in choosing the better estimates or admitting that the bearing is immeasurable, and finally to apply bias corrections when calibration information is available to yield a single final estimate. The algorithm was applied to a small but challenging set of events in a seismically active region. It demonstrated remarkable utility by providing better estimates and insights than previously available. Various monitoring implications are noted from these findings.

  18. Types of Stations and Activities at Each: 1) Short Station

    E-Print Network [OSTI]

    ) from starboard A-Frame­ Hydro Team · Fe CTD cast (1) at some locations - Wu · VPR cast (1) from stern A camera deployed from ice-Cooper/Grebmier team · If necessary, small boat work to access ice- Gradinger small boat ­ Moran At 5-6 Open Water Stations: · Van Veen Grab sampling from stern A-frame, 3/8" wire, 3

  19. LIQUIDSLIQUIDS GISAXSGISAXSGISAXS/WAXS station

    E-Print Network [OSTI]

    Ohta, Shigemi

    LIQUIDSLIQUIDS GISAXSGISAXSGISAXS/WAXS station: * Energy range: 2.1 to 24 keV * Low divergence mode 60m 55m 50m 45m 40m 35m 30m SAXS SAXS SCD SSA VFM HFM DCMKB's Gi-SAXS/WAXS sample Liquids sample Gi

  20. NOAA PMEL Station Chemistry Data

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Quinn, Patricia

    Submicron and supermicron samples are analyzed by ion chromatography for Cl-, NO3-, SO4-2, Na+, NH4+, K+, Mg2+, and Ca+2. The analysis of MSA-, Br-, and oxalate has been added to some stations. Samples also are analyzed for total mass by gravimetric analysis at 55 +/- 5% RH.

  1. Mobile Alternative Fueling Station Locator

    SciTech Connect (OSTI)

    Not Available

    2009-04-01

    The Department of Energy's Alternative Fueling Station Locator is available on-the-go via cell phones, BlackBerrys, or other personal handheld devices. The mobile locator allows users to find the five closest biodiesel, electricity, E85, hydrogen, natural gas, and propane fueling sites using Google technology.

  2. NOAA PMEL Station Chemistry Data

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Quinn, Patricia

    2008-04-04

    Submicron and supermicron samples are analyzed by ion chromatography for Cl-, NO3-, SO4-2, Na+, NH4+, K+, Mg2+, and Ca+2. The analysis of MSA-, Br-, and oxalate has been added to some stations. Samples also are analyzed for total mass by gravimetric analysis at 55 +/- 5% RH.

  3. COMPARATIVE COSTS OF CALIFORNIA CENTRAL STATION ELECTRICITY

    E-Print Network [OSTI]

    Laughlin, Robert B.

    CALIFORNIA ENERGY COMMISSION COMPARATIVE COSTS OF CALIFORNIA CENTRAL STATION ELECTRICITY GENERATION and Anitha Rednam, Comparative Costs of California Central Station Electricity Generation Technologies................................................................................................... 1 CHAPTER 1: Summary of Technology Costs

  4. Envelope amplifier design for wireless base-station power amplifiers

    E-Print Network [OSTI]

    Hsia, Chin

    2010-01-01

    Base Station Power Amplifiers . . . . . . . . . . . .for High Efficiency Bbase Station Power Amplifiers,” in IEEEfor Wireless Base-Station Power Amplifiers A dissertation

  5. Rocky Mountain Research Station 20142017 Strategic Framework

    E-Print Network [OSTI]

    Rocky Mountain Research Station 2014­2017 Strategic Framework #12;Rocky Mountain Research Station 240 West Prospect Fort Collins, CO 80526 (970) 498-1100 www.fs.fed.us/rmrs High mountain lake at GLEES (Glacier Lakes Ecosystem Experiments Site) #12;1ROCKY MOUNTAIN RESEARCH STATION -- 2014­2017 STRATEg

  6. Modeling pedestrian flows in train stations: The example of Lausanne railway station

    E-Print Network [OSTI]

    Bierlaire, Michel

    Modeling pedestrian flows in train stations: The example of Lausanne railway station Flurin S, April 15 ­ 17, 2015 #12;Modeling pedestrian flows in train stations: The example of Lausanne railway Engineering EPFL ­ Ecole Polytechnique Fédérale de Lausanne Modeling pedestrian flows in train stations

  7. LambdaStation: Exploiting Advance Networks In Data Intensive High Energy Physics Applications

    SciTech Connect (OSTI)

    Harvey B. Newman

    2009-09-11

    Lambda Station software implements selective, dynamic, secure path control between local storage & analysis facilities, and high bandwidth, wide-area networks (WANs). It is intended to facilitate use of desirable, alternate wide area network paths which may only be intermittently available, or subject to policies that restrict usage to specified traffic. Lambda Station clients gain awareness of potential alternate network paths via Clarens-based web services, including path characteristics such as bandwidth and availability. If alternate path setup is requested and granted, Lambda Station will configure the local network infrastructure to properly forward designated data flows via the alternate path. A fully functional implementation of Lambda Station, capable of dynamic alternate WAN path setup and teardown, has been successfully developed. A limited Lambda Station-awareness capability within the Storage Resource Manager (SRM) product has been developed. Lambda Station has been successfully tested in a number of venues, including Super Computing 2008. LambdaStation software, developed by the Fermilab team, enables dynamic allocation of alternate network paths for high impact traffic and to forward designated flows across LAN. It negotiates with reservation and provisioning systems of WAN control planes, be it based on SONET channels, demand tunnels, or dynamic circuit networks. It creates End-To-End circuit between single hosts, computer farms or networks with predictable performance characteristics, preserving QoS if supported in LAN and WAN and tied security policy allowing only specific traffic to be forwarded or received through created path. Lambda Station project also explores Network Awareness capabilities.

  8. Taipei terminal rail station : casting an urban gateway

    E-Print Network [OSTI]

    Tsai, May Deanna

    1991-01-01

    Access is a key issue in the design of railway stations. The evolution of the train station typology, has resulted in many types of stations based on the development of the stations' access. Since rail travel on a larger ...

  9. Timber Mountain Precipitation Monitoring Station

    SciTech Connect (OSTI)

    Lyles, Brad; McCurdy, Greg; Chapman, Jenny; Miller, Julianne

    2012-01-01

    A precipitation monitoring station was placed on the west flank of Timber Mountain during the year 2010. It is located in an isolated highland area near the western border of the Nevada National Security Site (NNSS), south of Pahute Mesa. The cost of the equipment, permitting, and installation was provided by the Environmental Monitoring Systems Initiative (EMSI) project. Data collection, analysis, and maintenance of the station during fiscal year 2011 was funded by the U.S. Department of Energy, National Nuclear Security Administration, Nevada Site Office Environmental Restoration, Soils Activity. The station is located near the western headwaters of Forty Mile Wash on the Nevada Test and Training Range (NTTR). Overland flows from precipitation events that occur in the Timber Mountain high elevation area cross several of the contaminated Soils project CAU (Corrective Action Unit) sites located in the Forty Mile Wash watershed. Rain-on-snow events in the early winter and spring around Timber Mountain have contributed to several significant flow events in Forty Mile Wash. The data from the new precipitation gauge at Timber Mountain will provide important information for determining runoff response to precipitation events in this area of the NNSS. Timber Mountain is also a groundwater recharge area, and estimation of recharge from precipitation was important for the EMSI project in determining groundwater flowpaths and designing effective groundwater monitoring for Yucca Mountain. Recharge estimation additionally provides benefit to the Underground Test Area Sub-project analysis of groundwater flow direction and velocity from nuclear test areas on Pahute Mesa. Additionally, this site provides data that has been used during wild fire events and provided a singular monitoring location of the extreme precipitation events during December 2010 (see data section for more details). This letter report provides a summary of the site location, equipment, and data collected in fiscal year 2011.

  10. Pilgrim Station | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIXsourceII JumpQuarterly SmartDB-2, Blue Mountain GeothermalPilger Estates HotStation Jump

  11. Hydrogen refueling station costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, Joan M; Jianxin, Ma

    2007-01-01

    station and equipment costs Capital equipment costs Non-a function of capital cost and is therefore represented intechnology and therefore capital cost and maintenance cost

  12. Reference Designs for Hydrogen Fueling Stations

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and piping & instrumentation diagrams * Ancillary Results - Near-term FCEV rollout scenario analysis year-by-year - Near-term hydrogen station rollout analysis year-by-year...

  13. Illinois Nuclear Profile - Byron Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Byron Generating Station" ,"Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration date"...

  14. Illinois Nuclear Profile - Dresden Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Dresden Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration...

  15. Illinois Nuclear Profile - Braidwood Generation Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Braidwood Generation Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License...

  16. Kansas Nuclear Profile - Wolf Creek Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    April 2012" "Next Release Date: February 2013" "Wolf Creek Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor...

  17. Illinois Nuclear Profile - Clinton Power Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Clinton Power Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration date"...

  18. Washington Nuclear Profile - Columbia Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Columbia Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration...

  19. Massachusetts Nuclear Profile - Pilgrim Nuclear Power Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Pilgrim Nuclear Power Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer cpacity factor (percent)","Type","Commercial operation date","License...

  20. Hydrogen Refueling Station Costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, J; Jianxin, Ma

    2006-01-01

    production equipment (e.g. electrolyzer, steam reformer) (iffeedstock costs differences. Electrolyzer stations yield theuses an alkaline electrolyzer powered by grid electricity to

  1. Hydrogen refueling station costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, Joan M; Jianxin, Ma

    2007-01-01

    production equipment (e.g. electrolyzer, steam reformer) (iffeedstock costs differences. Electrolyzer stations yield theuses an alkaline electrolyzer powered by grid electricity to

  2. Hydrogen Fueling Infrastructure Research and Station Technology...

    Broader source: Energy.gov (indexed) [DOE]

    An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project" held on November 18, 2014. Hydrogen Fueling Infrastructure Research and...

  3. Station Footprint: Separation Distances, Storage Options, and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    & Publications Light Duty Fuel Cell Electric Vehicle Hydrogen Fueling Protocol H2FIRST Reference Station Design Task: Project Deliverable 2-2 On-Board Storage Systems Analysis...

  4. NREL Dedicates Advanced Hydrogen Fueling Station | Community...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    NREL Dedicates Advanced Hydrogen Fueling Station Ceremony Coincides With National Hydrogen and Fuel Cell Day October 8, 2015 The Energy Department's National Renewable Energy...

  5. Reference Designs for Hydrogen Fueling Stations Webinar

    Broader source: Energy.gov [DOE]

    Access the recording and download the presentation slides from the Fuel Cell Technologies Office webinar "Reference Designs for Hydrogen Fueling Stations" held on October 13, 2015.

  6. Rocky Mountain Research Station Publishing Services Categories of Serial Station Publications

    E-Print Network [OSTI]

    Rocky Mountain Research Station ­ Publishing Services Categories of Serial Station Publications forestry public Information of a technical nature, but not necessarily an original report. Computer (Proc.) Forestry technicians/ practitioners, landowners, homeowners, general public Compilation

  7. Geotechnical Engineering at the Waterways Experiment Station

    E-Print Network [OSTI]

    motions, advanced methods of site characterization, liquefaction po tentia l of fine-grained and gra vellyGEOSPEC Geotechnical Engineering at the Waterways Experiment Station The Geotechnical Laboratory at the U.S. Army Engineer Waterways Experi ment Station (WES) was founded in 1932 and currently

  8. Station GPS permanente IPG Paris DGF Uchile

    E-Print Network [OSTI]

    Vigny, Christophe

    and autonomous energy (battery and solar panel). HISTORIC Semi-permanent GPS station installed since 08­DEC- 2007.08295 - 68.92680 DESCRIPTION North Chile II region, semipermanent GPS station from IPGP / DGF network telephone nearby NONO Electric power nearby NONO equipment storage available YESYES possibility of leaving

  9. Forest and Range Experiment Station

    E-Print Network [OSTI]

    wider range of suppliers. As working circles beyond the size of a single National Forest have recently. Alternatives for expansion of working circles must be assessed in light of present Forest Service timber management policy and the impacts of timber supply. These alternates include (a) combination of National

  10. LNG to CNG refueling stations

    SciTech Connect (OSTI)

    Branson, J.D. [ECOGAS Corp., Austin, TX (United States)

    1995-12-31

    While the fleet operator is concerned about the environment, he or she is going to make the choice based primarily on economics. Which fuel provides the lowest total operating cost? The calculation of this costing must include the price-per-gallon of the fuel delivered, as well as the tangible and intangible components of fuel delivery, such as downtime for vehicles during the refueling process, idle time for drivers during refueling, emissions costings resulting from compressor oil blow-by, inclusion of non-combustible constituents in the CNG, and energy consumption during the refueling process. Also, the upfront capital requirement of similar delivery capabilities must be compared. The use of LNG as the base resource for the delivered CNG, in conjunction with the utilization of a fully temperature-compressed LNG/CNG refueling system, eliminates many of the perceived shortfalls of CNG. An LNG/CNG refueling center designed to match the capabilities of the compressor-based station will have approximately the same initial capital requirement. However, because it derives its CNG sales product from the {minus}260 F LNG base product, thus availing itself of the natural physical properties of the cryogenic product, all other economic elements of the system favor the LNG/CNG product.

  11. High speed imager test station

    DOE Patents [OSTI]

    Yates, G.J.; Albright, K.L.; Turko, B.T.

    1995-11-14

    A test station enables the performance of a solid state imager (herein called a focal plane array or FPA) to be determined at high image frame rates. A programmable waveform generator is adapted to generate clock pulses at determinable rates for clock light-induced charges from a FPA. The FPA is mounted on an imager header board for placing the imager in operable proximity to level shifters for receiving the clock pulses and outputting pulses effective to clock charge from the pixels forming the FPA. Each of the clock level shifters is driven by leading and trailing edge portions of the clock pulses to reduce power dissipation in the FPA. Analog circuits receive output charge pulses clocked from the FPA pixels. The analog circuits condition the charge pulses to cancel noise in the pulses and to determine and hold a peak value of the charge for digitizing. A high speed digitizer receives the peak signal value and outputs a digital representation of each one of the charge pulses. A video system then displays an image associated with the digital representation of the output charge pulses clocked from the FPA. In one embodiment, the FPA image is formatted to a standard video format for display on conventional video equipment. 12 figs.

  12. High speed imager test station

    DOE Patents [OSTI]

    Yates, George J. (Santa Fe, NM); Albright, Kevin L. (Los Alamos, NM); Turko, Bojan T. (Moraga, CA)

    1995-01-01

    A test station enables the performance of a solid state imager (herein called a focal plane array or FPA) to be determined at high image frame rates. A programmable waveform generator is adapted to generate clock pulses at determinable rates for clock light-induced charges from a FPA. The FPA is mounted on an imager header board for placing the imager in operable proximity to level shifters for receiving the clock pulses and outputting pulses effective to clock charge from the pixels forming the FPA. Each of the clock level shifters is driven by leading and trailing edge portions of the clock pulses to reduce power dissipation in the FPA. Analog circuits receive output charge pulses clocked from the FPA pixels. The analog circuits condition the charge pulses to cancel noise in the pulses and to determine and hold a peak value of the charge for digitizing. A high speed digitizer receives the peak signal value and outputs a digital representation of each one of the charge pulses. A video system then displays an image associated with the digital representation of the output charge pulses clocked from the FPA. In one embodiment, the FPA image is formatted to a standard video format for display on conventional video equipment.

  13. Burner balancing Salem Harbor Station

    SciTech Connect (OSTI)

    Sload, A.W.; Dube, R.J.

    1995-12-31

    The traditional method of burner balancing is first to determine the fuel distribution, then to measure the economizer outlet excess oxygen distribution and to adjust the burners accordingly. Fuel distribution is typically measured by clean and dirty air probing. Coal pipe flow can then be adjusted, if necessary, through the use of coal pipe orificing or by other means. Primary air flow must be adjusted to meet the design criteria of the burner. Once coal pipe flow is balanced to within the desired criteria, secondary air flow to individual burners can be changed by adjusting windbox dampers, burner registers, shrouds or other devices in the secondary air stream. This paper discusses problems encountered in measuring excess O{sub 2} at the economizer outlet. It is important to recognize that O{sub 2} measurements at the economizer outlet, by themselves, can be very misleading. If measurement problems are suspected or encountered, an alternate approach similar to that described should be considered. The alternate method is not only useful for burner balancing but also can be used to help in calibrating the plant excess O{sub 2} instruments and provide an on line means of cross-checking excess air measurements. Balanced burners operate closer to their design stoichiometry, providing better NO{sub x} reduction. For Salem Harbor Station, this means a significant saving in urea consumption.

  14. Fuel Station of the Future- Innovative Approach to Fuel Cell...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Station of the Future- Innovative Approach to Fuel Cell Technology Unveiled in California Fuel Station of the Future- Innovative Approach to Fuel Cell Technology Unveiled in...

  15. Trona Injection Tests: Mirant Potomac River Station, Unit 1,...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Trona Injection Tests: Mirant Potomac River Station, Unit 1, November 12 to December 23, 2005, Summary Report Trona Injection Tests: Mirant Potomac River Station, Unit 1, November...

  16. The Status of Renewable Hydrogen and Energy Station Technologies...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    The Status of Renewable Hydrogen and Energy Station Technologies and Policy Recommendations The Status of Renewable Hydrogen and Energy Station Technologies and Policy...

  17. Puge County Gongdefang Hydropower Station Investment and Development...

    Open Energy Info (EERE)

    Puge County Gongdefang Hydropower Station Investment and Development Co Ltd Jump to: navigation, search Name: Puge County Gongdefang Hydropower Station Investment and Development...

  18. Hydrogen Fueling Station in Honolulu, Hawaii Feasibility Analysis...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fueling Station in Honolulu, Hawaii Feasibility Analysis Hydrogen Fueling Station in Honolulu, Hawaii Feasibility Analysis This feasibility report assesses the technical and...

  19. License Amendment Request for Storing Exelon Sister Nuclear Stations...

    Office of Scientific and Technical Information (OSTI)

    License Amendment Request for Storing Exelon Sister Nuclear Stations Class BC LLRW in the LaSalle Station Interim Radwaste Storage Facility - 13620 Citation Details In-Document...

  20. Alternative Fueling Station Locator App Provides Info at Your...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    stations that offer electricity, natural gas, biodiesel, E85, propane, or hydrogen. | Energy Department The Alternative Fueling Station Locator iPhone app helps you find...

  1. Hydrogen Refueling Station Costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, J; Jianxin, Ma

    2006-01-01

    Well-to-wheels analysis of hydrogen based fuel-cell vehicleJP, et al. Distributed Hydrogen Fueling Systems Analysis,”Year 2006 UCD—ITS—RR—06—04 Hydrogen Refueling Station Costs

  2. COMPARATIVE COSTS OF CALIFORNIA CENTRAL STATION ELECTRICITY

    E-Print Network [OSTI]

    CALIFORNIA ENERGY COMMISSION COMPARATIVE COSTS OF CALIFORNIA CENTRAL STATION ELECTRICITY GENERATIONCann Please use the following citation for this report: Klein, Joel. 2009. Comparative Costs of California............................................................................................................................1 Changes in the Cost of Generation Model

  3. (Surveying isolated diesel power stations in Guatemala)

    SciTech Connect (OSTI)

    Waddle, D.B.

    1990-02-26

    I travelled to Guatemala City, Guatemala, to lead a team of specialists to study the operating, administrative, and management efficiency of isolated diesel power plants, operated by Instituto Nacional de Electrificacion (INDE). The study is part of a global initiative managed jointly by the Agency for International Development and the World Bank. The power plants were audited, including INDE's largest isolated diesel station, and two, much smaller municipal and privately owned stations. I returned to Oak Ridge on February 22, 1990.

  4. Wintering Steer Calves at the Spur Station

    E-Print Network [OSTI]

    Jones, J. H.; Fisher, C. E.; Marion, P. T.

    1956-01-01

    at the Spur Station SUMMARY Winter maintenance experiments were conducted with 1,034 steer calves at the Spur station dur. ing the 14-year period from the fall of 1941 to the spring of 1955. Results of these comparative trials, in most instances, were... made approximately the same gain during the winter as heavy calves averaging 466 pounds. Wheat pasture provided the lowest cost of winter maintenance for calves. Sorghum fields and na- tive grass supplemented with cottonseed cake were intermediate...

  5. Solar and Infrared Radiation Station (SIRS) Handbook

    SciTech Connect (OSTI)

    Stoffel, T

    2005-07-01

    The Solar Infrared Radiation Station (SIRS) provides continuous measurements of broadband shortwave (solar) and longwave (atmospheric or infrared) irradiances for downwelling and upwelling components. The following six irradiance measurements are collected from a network of stations to help determine the total radiative flux exchange within the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Climate Research Facility: • Direct normal shortwave (solar beam) • Diffuse horizontal shortwave (sky) • Global horizontal shortwave (total hemispheric) • Upwelling shortwave (reflected) • Downwelling longwave (atmospheric infrared) • Upwelling longwave (surface infrared)

  6. Utilities respond to nuclear station blackout rule

    SciTech Connect (OSTI)

    Rubin, A.M.; Beasley, B.; Tenera, L.P

    1990-02-01

    The authors discuss how nuclear plants in the United States have taken actions to respond to the NRC Station Blackout Rule, 10CFR50.63. The rule requires that each light water cooled nuclear power plant licensed to operate must be able to withstand for a specified duration and recover from a station blackout. Station blackout is defined as the complete loss of a-c power to the essential and non-essential switch-gear buses in a nuclear power plant. A station blackout results from the loss of all off-site power as well as the on-site emergency a-c power system. There are two basic approaches to meeting the station blackout rule. One is to cope with a station blackout independent of a-c power. Coping, as it is called, means the ability of a plant to achieve and maintain a safe shutdown condition. The second approach is to provide an alternate a-c power source (AAC).

  7. Optimal Base Station Density for Power Efficiency in Cellular Networks

    E-Print Network [OSTI]

    Haenggi, Martin

    Optimal Base Station Density for Power Efficiency in Cellular Networks Sanglap Sarkar, Radha, power consumption, power efficiency, optimal base station density. I. INTRODUCTION Cell size reduction by increasing the number of macro base stations or adding tiers of low powered base stations. There are two

  8. Competitive Charging Station Pricing for Plug-in Electric Vehicles

    E-Print Network [OSTI]

    Huang, Jianwei

    Competitive Charging Station Pricing for Plug-in Electric Vehicles Wei Yuan, Member, IEEE, Jianwei considers the problem of charging station pricing and station selection of plug-in electric vehicles (PEVs). Every PEV needs to select a charging station by con- sidering the charging prices, waiting times

  9. Hydrogen Fueling - Coming Soon to a Station Near You (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2009-04-01

    Fact sheet providing information useful to local permitting officials facing hydrogen fueling station proposals.

  10. Station GPS permanente IPG Paris DGF Uchile UNAP Iquique

    E-Print Network [OSTI]

    Vigny, Christophe

    Colocated with seismic station. Pilar constructed in reinforced concrete. Inox 12 cm rod (Delmont type

  11. Technology, Safety and Costs of Decommissioning Nuclear Reactors At Multiple-Reactor Stations

    SciTech Connect (OSTI)

    Wittenbrock, N. G.

    1982-01-01

    Safety and cost information is developed for the conceptual decommissioning of large (1175-MWe) pressurized water reactors (PWRs) and large (1155-MWe) boiling water reactors {BWRs) at multiple-reactor stations. Three decommissioning alternatives are studied: DECON (immediate decontamination), SAFSTOR (safe storage followed by deferred decontamination), and ENTOMB (entombment). Safety and costs of decommissioning are estimated by determining the impact of probable features of multiple-reactor-station operation that are considered to be unavailable at a single-reactor station, and applying these estimated impacts to the decommissioning costs and radiation doses estimated in previous PWR and BWR decommissioning studies. The multiple-reactor-station features analyzed are: the use of interim onsite nuclear waste storage with later removal to an offsite nuclear waste disposal facility, the use of permanent onsite nuclear waste disposal, the dedication of the site to nuclear power generation, and the provision of centralized services. Five scenarios for decommissioning reactors at a multiple-reactor station are investigated. The number of reactors on a site is assumed to be either four or ten; nuclear waste disposal is varied between immediate offsite disposal, interim onsite storage, and immediate onsite disposal. It is assumed that the decommissioned reactors are not replaced in one scenario but are replaced in the other scenarios. Centralized service facilities are provided in two scenarios but are not provided in the other three. Decommissioning of a PWR or a BWR at a multiple-reactor station probably will be less costly and result in lower radiation doses than decommissioning an identical reactor at a single-reactor station. Regardless of whether the light water reactor being decommissioned is at a single- or multiple-reactor station: • the estimated occupational radiation dose for decommissioning an LWR is lowest for SAFSTOR and highest for DECON • the estimated cost of decommissioning a PWR is lowest for ENTOMB and highest for SAFSTOR • the estimated cost of decommissioning a BWR is lowest for OECON and highest for SAFSTOR. In all cases, SAFSTOR has the lowest occupational radiation dose and the highest cost.

  12. Station blackout transients in the semiscale facility

    SciTech Connect (OSTI)

    Chapman, J.C.

    1985-12-01

    The test results of station blackout transients conducted in the Semiscale MOD-2B facility are discussed in this report. The Semiscale MOD-2B facility simulates a pressurized water reactor (PWR) power plant. The experiments were initiated from conditions typical of PWR plant operating conditions (primary pressure of 15.2 MPa (2205 psi) and cold leg fluid temperature of 550 K (530F)). Five station blackout experiments were conducted, Three tests in the Power Loss (PL) Test Series and the two Primary Boil-off (PBO) Tests. The responses of these tests were analyzed and compared. However, only one test response (S-PL-2) is presented and discussed in detail. The S-PL-2 experiment is characterized by examining the responses of the primary and secondary pressures and fluid temperatures, the pressurizer liquid level, the primary fluid distribution, and the core thermal behavior. The mechanisms driving the S-PL-2 responses, the main elements of the station blackout transient, the influences of initial and boundary conditions and other transient that may appear similar to a station blackout are also discussed. Information pertinent to station blackout nuclear safety issues is presented in the report. 13 refs., 44 figs.

  13. Technological advancements in NGV station design

    SciTech Connect (OSTI)

    Ledbetter, G.S.; Grimmer, J.E.; Ketcham, E.T.

    1995-12-31

    Hurricane Compressors` SPRINT System (patent pending) is designed to increase the rate of flow from compressed natural gas (CNG) fuel stations and provide greater utilization of stored CNG than is available from traditional compressor stations. Using a novel method of adapting compressor operation to changes in CNG storage system pressures, this advanced technology provides an alternative mechanism for fuel delivery when demand for fuel is high. Transfer of CNG may be made at higher rates of flow than would be possible either from a pressure depleted storage system or directly from the compressor.

  14. Refueling stations for natural gas vehicles

    SciTech Connect (OSTI)

    Blazek, C.F.; Kinast, J.A.; Biederman, R.T.; Jasionowski, W.

    1991-01-01

    The unavailability of natural gas vehicle (NGV) refueling stations constitutes one of the major barriers to the wide spread utilization of natural gas in the transportation market. The purpose of this paper is to review and evaluate the current technical and economic status of compressed natural gas vehicle refueling stations and to identify the components or design features that offer the greatest potential for performance improvements and/or cost reductions. Both fast-fill- and slow-fill-type refueling systems will be discussed. 4 refs., 10 figs., 6 tabs.

  15. Pump station for radioactive waste water

    DOE Patents [OSTI]

    Whitton, John P.; Klos, Dean M.; Carrara, Danny T.; Minno, John J.

    2003-11-18

    A pump station for transferring radioactive particle containing waste water, includes: (a.) an enclosed sump having a vertically elongated right frusto conical wall surface and a bottom surface and (b.) a submersible volute centrifugal pump having a horizontally rotating impeller and a volute exterior surface. The sump interior surface, the bottom surface and the volute exterior surface are made of stainless steel having a 30 Ra or finer surface finish. A 15 Ra finish has been found to be most cost effective. The pump station is used for transferring waste water, without accumulation of radioactive fines.

  16. Real Time (20 Second) Data Base Single Loop (Packed into 3 bytes)

    E-Print Network [OSTI]

    ) Data Base Single Loop (Packed into 3 bytes) ------------------------------------------- Data Element;------------------------------------------------------------------------- --- Real Time (20 Second) Data Base Station (Packed into 3 bytes Loops | 3 | [0]|Data Present, 0=No Data | |Scan Cnt| 11 | [0]|

  17. The Village Base Station Kurtis Heimerl

    E-Print Network [OSTI]

    California at Berkeley, University of

    deployment due to low power requirements that enable local generation via solar or wind; · explicit support. At around 20W, its power consumption is low enough to avoid diesel genera- tors and the corresponding damaging equipment [2]. We propose operating the entire base station on solely wind or solar power, which

  18. City of College Station's Thermographic Mobile Scan 

    E-Print Network [OSTI]

    Shear, C. K.

    1986-01-01

    During the first quarter of 1986, the City of College Station conducted a thermographic mobile scan of the entire city. A thermographic mobile scan is a process by which heat loss/heat gain data is accumulated by a vehicle traveling the city...

  19. Technical Design Report, Second Target Station

    SciTech Connect (OSTI)

    Galambos, John D.; Anderson, David E.; Bechtol, D.; Bethea, Katie L.; Brown, N.; Carden, W. F.; Chae, Steven M.; Clark, A.; Counce, Deborah M.; Craft, K.; Crofford, Mark T.; Collins, Richard M.; Cousineau, Sarah M.; Curry, Douglas E.; Cutler, Roy I.; Dayton, Michael J.; Dean, Robert A.; Deibele, Craig E.; Doleans, Marc; Dye, T.; Eason, Bob H.; Eckroth, James A.; Fincrock, C.; Fritts, S.; Gallmeier, Franz X.; Gawne, Ken R.; Hartman, Steven M.; Herwig, Kenneth W.; Hess, S.; Holmes, Jeffrey A.; Horak, Charlie M.; Howell, Matthew P.; Iverson, Erik B.; Jacobs, Lorelei L.; Jones, Larry C.; Johnson, B.; Johnson, S.; Kasemir, Kay; Kim, Sang-Ho; Laughon, Gregory J.; Lu, W.; Mahoney, Kelly L.; Mammosser, John; McManamy, T.; Michilini, M.; Middendorf, Mark E.; O'Neal, Ed; Nemec, B.; Peters, Roy Cecil; Plum, Michael A.; Reagan, G.; Remec, Igor; Rennich, Mark J.; Riemer, Bernie; Saethre, Robert B.; Schubert, James Phillip; Shishlo, Andrei P.; Smith, C. Craig; Strong, William Herb; Tallant, Kathie M.; Tennant, David Alan; Thibadeau, Barbara M.; Trumble, S.; Trotter, Steven M.; Wang, Z.; Webb, Steven B.; Williams, Derrick C.; White, Karen S.; Zhao, Jinkui

    2015-01-01

    The Second Target Station (STS) is a proposed upgrade for SNS. It includes a doubling of the accelerator power and an additional instrument hall. The new instrument hall will receive a 467 kW 10 Hz beam. The parameters and preliminary design aspects of the STS are presented for the accelerator, target systems, instrument hall, instruments and civil construction aspects.

  20. COMPARATIVE COSTS OF CALIFORNIA CENTRAL STATION ELECTRICITY

    E-Print Network [OSTI]

    CALIFORNIA ENERGY COMMISSION COMPARATIVE COSTS OF CALIFORNIA CENTRAL STATION ELECTRICITY GENERATION in this paper. #12;ABSTRACT In this 2007 report of the cost of generation of electricity for California located technologies, California Energy Commission staff provides levelized costs, including the cost assumptions

  1. TEST STATION SALE OF PERFORMANCE TESTED BULLS

    E-Print Network [OSTI]

    Tennessee, University of

    in the test had to meet minimum performance requirements. Those were: CREEP NON-CREEP Adj 205 day wt. 560 520AS-B428 U T BULL TEST STATION SALE OF PERFORMANCE TESTED BULLS THURSDAY, MARCH 8, 2012 12:00 NOON IN GREENEVILLE AND KNOXVILLE LIVESTOCK CENTER http://animalscience.ag.utk.edu/ (For video) #12;UT BULL TEST

  2. Economic Analysis of Hydrogen Energy Station Concepts: Are "H 2E-Stations" a Key Link to a Hydrogen Fuel Cell Vehicle Infrastructure?

    E-Print Network [OSTI]

    Lipman, Timothy E.; Edwards, Jennifer L.; Kammen, Daniel M.

    2002-01-01

    ECONOMIC ANALYSIS OF HYDROGEN ENERGY STATION CONCEPTS: ARE 'Economic Analysis of Hydrogen Energy Station Concepts: Are “the concept of the “hydrogen energy station”(H 2 E-Station).

  3. Extended Edited Synoptic Cloud Reports from Ships and Land Stations Over the Globe, 1952-1996

    SciTech Connect (OSTI)

    Hahn, C.J.; Warren, S.G.

    1999-08-01

    Surface synoptic weather reports for the entire globe, gathered from various available data sets, were processed, edited, and rewritten to provide a single data set of individual observations of clouds, spanning the 44 years 1952-1995 for ship data and the 26 years 1971-1996 for land station data. In addition to the cloud portion of the synoptic report, each edited report also includes the associated pressure, present weather, wind, air temperature, and dew point (and sea surface temperature over oceans).

  4. An Assessment of the Near-Term Costs of Hydrogen Refueling Stations and Station Components

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Lipman, Timothy

    2006-01-01

    economics. Summary of Results Costs are calculated for sevenTable ES-1. Station costs are presented both individually (was selected because the costs provided by Fuel Cell Energy

  5. VELO[city] : rethinking the multi-modal urban station

    E-Print Network [OSTI]

    Dickson, Amanda, 1974-

    2003-01-01

    Train travel was once integral to the urban condition. Railway stations and rural depots were designed as machines for efficiency and it was within the station that one could escape the chaos of the city to become a part ...

  6. Fact #816: February 10, 2014 Natural Gas Refueling Stations Grow...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    6: February 10, 2014 Natural Gas Refueling Stations Grow Over the Last Ten Years Fact 816: February 10, 2014 Natural Gas Refueling Stations Grow Over the Last Ten Years In 2003...

  7. Webinar October 13: Reference Designs for Hydrogen Fueling Stations...

    Broader source: Energy.gov (indexed) [DOE]

    titled "Reference Designs for Hydrogen Fueling Stations" on Tuesday, October 13, from 12 to 1 p.m. Eastern Daylight Time (EDT). The goal of the H2FIRST Reference Station Design...

  8. H2FIRST Reference Station Design Task: Project Deliverable 2...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Reference Station Design Task: Project Deliverable 2-2 H2FIRST Reference Station Design Task: Project Deliverable 2-2 This H2FIRST project report, published in April 2015, presents...

  9. Which way is up : towards accessible wayfinding in transit stations

    E-Print Network [OSTI]

    Leven, Dalia (Dalia Beth)

    2006-01-01

    Passengers' most frequent interaction with a rail transit system is at its stations, which represent the beginning, the end and sometimes the middle of transit trips. The design of these stations can greatly affect a user's ...

  10. Station GPS permanente IPG Paris DGF Uchile UNAP Iquique

    E-Print Network [OSTI]

    Vigny, Christophe

    .691 DESCRIPTION Permanent GPS station North Chili I region. MONUMENTATION Inox 12 cm rod (Delmont type) scealed

  11. Station GPS permanente IPG Paris DGF Uchile UNAP Iquique

    E-Print Network [OSTI]

    Vigny, Christophe

    Colocated with seismic station. Bedrock. Inox 12 cm rod (Delmont type) scealed in bedrock. PG-A1 antena

  12. Hydrogen Energy Stations: Poly-Production of Electricity, Hydrogen, and Thermal Energy

    E-Print Network [OSTI]

    Lipman, Timothy; Brooks, Cameron

    2006-01-01

    shaving and backup power, and the station is expected toor “onsite power”), energy stations offer a potentially moreCharacteristics of Energy Station Power Technologies Low/

  13. Plug-In Electric Vehicle Handbook for Public Charging Station Hosts

    SciTech Connect (OSTI)

    2012-04-01

    This handbook answers basic questions about plug-in electric vehicles, charging stations, charging equipment, and considerations for station owners, property owners, and station hosts.

  14. Plug-In Electric Vehicle Handbook for Public Charging Station Hosts (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2012-04-01

    This handbook answers basic questions about plug-in electric vehicles, charging stations, charging equipment, and considerations for station owners, property owners, and station hosts.

  15. Central Station DHC Phase 1 feasibility

    SciTech Connect (OSTI)

    Henderson, H.L.

    1992-03-01

    This project assisted a private real estate developer in technically assessing the feasibility of integrating a central DHC system into a proposed 72 acre area mixed-use Planned Development (Central Station) just south of the Chicago Central Business District (Loop). The technical assessment concluded that a district heating and cooling system for Central Station will be feasible, provided that a major anchor load can be connected to the system. The system conceived for the site employs a modular approach that adjusts production capacity to actual load growth. The design concept includes gas-fired boilers for heating, gas turbine driven chillers for base loading, electric motor driven chillers for peaking, steam turbines for peak power and back pressure operation, and chilled water storage. Energy will be supplied to the users in the form of steam or low temperature hot water for heating, and low temperature chilled water for cooling.

  16. BIOMASS COGASIFICATION AT POLK POWER STATION

    SciTech Connect (OSTI)

    John McDaniel

    2002-05-01

    Part of a closed loop biomass crop was recently harvested to produce electricity in Tampa Electric's Polk Power Station Unit No.1. No technical impediments to incorporating a small percentage of biomass into Polk Power Station's fuel mix were identified. Appropriate dedicated storage and handling equipment would be required for routine biomass use. Polk Unit No.1 is an integrated gasification combined cycle (IGCC) power plant. IGCC is a new approach to generating electricity cleanly from solid fuels such as coal, petroleum coke, The purpose of this experiment was to demonstrate the Polk Unit No.1 could process biomass as a fraction of its fuel without an adverse impact on availability and plant performance. The biomass chosen for the test was part of a crop of closed loop Eucalyptus trees.

  17. Fort Collins CSU Campus Weather Station Commemoration and Open House

    E-Print Network [OSTI]

    Collett Jr., Jeffrey L.

    Fort Collins CSU Campus Weather Station Commemoration and Open House Please join us in celebrating the fascinating history and important scientific contributions of the Campus Weather Station to Colorado State, July 28, 2014 from 3 - 6 p.m. with remarks at 3:30 p.m. At the Campus Weather Station*** Community Open

  18. Power-aware Base Station Positioning for Sensor Networks

    E-Print Network [OSTI]

    Bogdanov, Andrej

    Power-aware Base Station Positioning for Sensor Networks Andrej Bogdanov Elitza Maneva Samantha station, where the data can be processed. There are several power metrics that one can consider optimizing consider the problem of positioning data collecting base stations in a sensor network. We show

  19. Xcel Energy Comanche Station: Pueblo, Colorado (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Stoffel, T.; Andreas, A.

    A partnership with industry and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

  20. Xcel Energy Comanche Station: Pueblo, Colorado (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Stoffel, T.; Andreas, A.

    2007-06-20

    A partnership with industry and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

  1. Reykjanes Geothermal Power Station | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onRAPID/Geothermal/Exploration/ColoradoRemsenburg-Speonk, New York: EnergyOpenReykjanes Geothermal Power Station Jump to:

  2. Alternative Fueling Station Locator | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematics And StatisticsProgram ManagerCorridor Designations in 11Alternative Fueling Station Locator

  3. Antenna unit and radio base station therewith

    DOE Patents [OSTI]

    Kuwahara, Mikio; Doi, Nobukazu; Suzuki, Toshiro; Ishida, Yuji; Inoue, Takashi; Niida, Sumaru

    2007-04-10

    Phase and amplitude deviations, which are generated, for example, by cables connecting an array antenna of a CDMA base station and the base station, are calibrated in the baseband. The base station comprises: an antenna apparatus 1; couplers 2; an RF unit 3 that converts a receive signal to a baseband signal, converts a transmit signal to a radio frequency, and performs power control; an A/D converter 4 for converting a receive signal to a digital signal; a receive beam form unit 6 that multiplies the receive signal by semi-fixed weight; a despreader 7 for this signal input; a time-space demodulator 8 for demodulating user data; a despreader 9 for probe signal; a space modulator 14 for user data; a spreader 13 for user signal; a channel combiner 12; a Tx calibrater 11 for controlling calibration of a signal; a D/A converter 10; a unit 16 for calculation of correlation matrix for generating a probe signal used for controlling an Rx calibration system and a TX calibration system; a spreader 17 for probe signal; a power control unit 18; a D/A converter 19; an RF unit 20 for probe signal; an A/D converter 21 for signal from the couplers 2; and a despreader 22.

  4. Radio Frequency Station - Beam Dynamics Interaction in Circular Accelerators

    SciTech Connect (OSTI)

    Mastoridis, Themistoklis; /Stanford U., Elect. Eng. Dept. /SLAC

    2011-03-01

    The longitudinal beam dynamics in circular accelerators is mainly defined by the interaction of the beam current with the accelerating Radio Frequency (RF) stations. For stable operation, Low Level RF (LLRF) feedback systems are employed to reduce coherent instabilities and regulate the accelerating voltage. The LLRF system design has implications for the dynamics and stability of the closed-loop RF systems as well as for the particle beam, and is very sensitive to the operating range of accelerator currents and energies. Stability of the RF loop and the beam are necessary conditions for reliable machine operation. This dissertation describes theoretical formalisms and models that determine the longitudinal beam dynamics based on the LLRF implementation, time domain simulations that capture the dynamic behavior of the RF station-beam interaction, and measurements from the Positron-Electron Project (PEP-II) and the Large Hadron Collider (LHC) that validate the models and simulations. These models and simulations are structured to capture the technical characteristics of the system (noise contributions, non-linear elements, and more). As such, they provide useful results and insight for the development and design of future LLRF feedback systems. They also provide the opportunity to study diverse longitudinal beam dynamics effects such as coupled-bunch impedance driven instabilities and single bunch longitudinal emittance growth. Coupled-bunch instabilities and RF station power were the performance limiting effects for PEP-II. The sensitivity of the instabilities to individual LLRF parameters, the effectiveness of alternative operational algorithms, and the possible tradeoffs between RF loop and beam stability were studied. New algorithms were implemented, with significant performance improvement leading to a world record current during the last PEP-II run of 3212 mA for the Low Energy Ring. Longitudinal beam emittance growth due to RF noise is a major concern for LHC. Simulations studies and measurements were conducted that clearly show the correlation between RF noise and longitudinal bunch emittance, identify the major LLRF noise contributions, and determine the RF component dominating this effect. With these results, LHC upgrades and alternative algorithms are evaluated to reduce longitudinal emittance growth during operations. The applications of this work are described with regard to future machines and analysis of new technical implementations, as well as to possible future work which would continue the directions of this dissertation.

  5. Hanna Franberg-Delahaye SPIRAL 2 production station 4th HPTW 2011 Page 1 SPIRAL 2 production station

    E-Print Network [OSTI]

    McDonald, Kirk

    Hanna Franberg-Delahaye SPIRAL 2 production station ­ 4th HPTW 2011 Page 1 SPIRAL 2 production station Hanna Frånberg Delahaye Radioactive beam production GANIL-SPIRAL 2, Caen, France May 3, 2011 #12;Hanna Franberg-Delahaye SPIRAL 2 production station ­ 4th HPTW 2011 Page 2 Lay out of the presentation

  6. Polk power station syngas cooling system

    SciTech Connect (OSTI)

    Jenkins, S.D.

    1995-01-01

    Tampa Electric Company (TEC) is in the site development and construction phase of the new Polk Power Station Unit No. 1. This will be the first unit at a new site and will use Integrated Gasification Combined Cycle (IGCC) Technology. The unit will utilize Texaco`s oxygen-blown, entrained-flow coal gasification, along with combined cycle power generation, to produce nominal 260MW. Integral to the gasification process is the syngas cooling system. The design, integration, fabrication, transportation, and erection of this equipment have provided and continue to provide major challenges for this project.

  7. Repowering of the Midland Nuclear Station 

    E-Print Network [OSTI]

    Gatlin, C. E. Jr.; Vellender, G. C.; Mooney, J. A.

    1988-01-01

    , Michigan The conversion of the Midland Nuclear Station to a combined cycle power facility is the first of its kind. The eXisting nuclear steam turbine, combined with new, natural-gas-fired gas turbines, will create the largest cogeneration facility... in the midst of a repa..'erin;J that will convert it to a natural gas-fired carbined cycle cogeneration plant. 'Ihe nuclear project started in 1967 as a two unit plant utilizin;J pressurized water reactors to supply 1,357 MW of electric generatin...

  8. Farinello Geothermal Power Station | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTIONRobertsdale, AlabamaETEC GmbHFarinello Geothermal Power Station Jump to: navigation, search

  9. Nesjavellir Geothermal Power Station | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPI Ventures Ltd JumpNesjavellir Geothermal Power Station Jump to: navigation,

  10. Boyd Station LLC | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LISTStar Energy LLC JumpBiossence JumpJersey Logo: BostonStation LLC Jump to:

  11. Alternative Fuels Data Center: Biodiesel Fueling Stations

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home Page on Digg FindPortsas a Vehicle FuelFueling Stations to

  12. Alternative Fuels Data Center: Ethanol Fueling Stations

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home Page on Digg FindPortsas aEthanol Benefits andFueling Stations

  13. 50,000-Watt AM Stations IA | MB | MI | MN | NE | ND | ON | SD | WI | Station News | Owners | TV Captures | Links

    E-Print Network [OSTI]

    Allen, Gale

    that broadcast with a power of 50,000 Watts day and night. Some of these stations are what was once known50,000-Watt AM Stations IA | MB | MI | MN | NE | ND | ON | SD | WI | Station News | Owners | TV Captures | Links 50,000-Watt AM stations This list includes AM stations in the United States and Canada

  14. SHORT COMMUNICATION Metabolic oxygen consumption measurement with a single-cell

    E-Print Network [OSTI]

    Brenner, David Jonathan

    SHORT COMMUNICATION Metabolic oxygen consumption measurement with a single-cell biosensor after Ó Springer-Verlag Berlin Heidelberg 2014 Abstract A noninvasive, self-referencing biosensor Microbeam II end station. A single-cell oxygen consumption measurement has been conducted with this type

  15. The AP1000{sup R} nuclear power plant innovative features for extended station blackout mitigation

    SciTech Connect (OSTI)

    Vereb, F.; Winters, J.; Schulz, T.; Cummins, E.; Oriani, L. [Westinghouse Electric Company LLC, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2012-07-01

    Station Blackout (SBO) is defined as 'a condition wherein a nuclear power plant sustains a loss of all offsite electric power system concurrent with turbine trip and unavailability of all onsite emergency alternating current (AC) power system. Station blackout does not include the loss of available AC power to buses fed by station batteries through inverters or by alternate AC sources as defined in this section, nor does it assume a concurrent single failure or design basis accident...' in accordance with Reference 1. In this paper, the innovative features of the AP1000 plant design are described with their operation in the scenario of an extended station blackout event. General operation of the passive safety systems are described as well as the unique features which allow the AP1000 plant to cope for at least 7 days during station blackout. Points of emphasis will include: - Passive safety system operation during SBO - 'Fail-safe' nature of key passive safety system valves; automatically places the valve in a conservatively safe alignment even in case of multiple failures in all power supply systems, including normal AC and battery backup - Passive Spent Fuel Pool cooling and makeup water supply during SBO - Robustness of AP1000 plant due to the location of key systems, structures and components required for Safe Shutdown - Diverse means of supplying makeup water to the Passive Containment Cooling System (PCS) and the Spent Fuel Pool (SFP) through use of an engineered, safety-related piping interface and portable equipment, as well as with permanently installed onsite ancillary equipment. (authors)

  16. Recovery sequences for a station blackout accident at the Grand Gulf Nuclear Station

    SciTech Connect (OSTI)

    Carbajo, J.J. [Martin Marietta Energy Systems, Oak Ridge, TN (United States)

    1995-12-31

    Recovery sequences for a low-pressure, short term, station blackout severe accident at the Grand Gulf power plant have been investigated using the computer code MELCOR, version 1.8.3 PN. This paper investigates the effect of reflood timing and mass flow rate on accident recovery.

  17. Re: Potomac River Generating Station Department of Energy, Case...

    Office of Environmental Management (EM)

    PEPCO is providing you with information regarding the planned transmission maintenance outage Notification of Planned 230kV Outage at Potomac River Generating Station Comments and...

  18. Re: Potomac River Generating Station Department of Energy Case...

    Energy Savers [EERE]

    PEPCO is providing you with information regarding the planned transmission maintenance outage Re: Potomac River Generating Station Department of Energy Case No. EO-05-01: PEPCO is...

  19. Sandia Energy - More California Gas Stations Can Provide Hydrogen...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    More California Gas Stations Can Provide Hydrogen than Previously Thought, Sandia Study Says Home Infrastructure Security Energy Transportation Energy CRF Facilities News News &...

  20. Webinar May 12: Overview of Station Analysis Tools Developed...

    Energy Savers [EERE]

    Daylight Time. This webinar will provide a basic introduction to two new models-the Hydrogen Refueling Station Analysis Model (HRSAM) and the Hydrogen Financial Analysis Scenario...

  1. New York Nuclear Profile - Nine Mile Point Nuclear Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Nine Mile Point Nuclear Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License...

  2. New Jersey Nuclear Profile - PSEG Salem Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    PSEG Salem Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License...

  3. New Jersey Nuclear Profile - PSEG Hope Creek Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    PSEG Hope Creek Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License...

  4. California Nuclear Profile - San Onofre Nuclear Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    San Onofre Nuclear Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License...

  5. Illinois Nuclear Profile - LaSalle Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    LaSalle Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration...

  6. Microgrid V2G Charging Station Interconnection Testing (Presentation)

    SciTech Connect (OSTI)

    Simpson, M.

    2013-07-01

    This presentation by Mike Simpson of the National Renewable Energy Laboratory (NREL) describes NREL's microgrid vehicle-to-grid charging station interconnection testing.

  7. H2FIRST Reference Station Design Task: Project Deliverable 2...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    98 List of Tables Table ES-1. Station Types Selected for Detailed Reference Design Development ... v Table 1. Changed Input Parameters...

  8. College Station Utilities- Residential Energy Back II Rebate Program

    Broader source: Energy.gov [DOE]

    College Station Utilities offers an incentive for residential customers to install energy efficient HVAC equipment through the Energy Back II Program. Rebates only apply for replacements in...

  9. EECBG Success Story: Police Station Triples Solar Power - and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    the North Community Police Substation in Henderson, Nevada installed new, roof-top photovoltaic panels that provide almost 40% of the station's electricity, up from 12.5%....

  10. NREL Dedicates Advanced Hydrogen Fueling Station - News Releases...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Dedicates Advanced Hydrogen Fueling Station Ceremony Coincides With National Hydrogen and Fuel Cell Day October 8, 2015 The Energy Department's National Renewable Energy Laboratory...

  11. 20,000 and Counting: Alternative Fueling and Charging Stations...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    or by vehicle technology. Shannon Shea Clean Cities Communications Manager Thanks to the Energy Department's Alternative Fueling Station Locator tool, it's easier than ever for...

  12. Distributed Hydrogen Fueling Station Based on GEGR SCPO Technology...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fueling Station Based on GEGR SCPO Technology (Presentation) Presented at the 2007 Bio-Derived Liquids to Hydrogen Distributed Reforming Working Group held November 6, 2007 in...

  13. Solar Powered Radioactive Air Monitoring Stations

    SciTech Connect (OSTI)

    Barnett, J. M.; Bisping, Lynn E.; Gervais, Todd L.

    2013-10-30

    Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

  14. Project X Energy Station Workshop Report. Report by the Organizers and Co-Conveners of the Project X Energy Station Workshop

    SciTech Connect (OSTI)

    Asner, David M.; Hurh, Patrick; Brady Raap, Michaele C.; Gohar, Yoursy; Peterson, Mary E.; Pithcer, Eric; Riemer, Bernie; Senor, David J.; Wootan, David W.

    2013-06-14

    Project X Energy Station Workshop Report Report by the Organizers and Co-Conveners of the Project X Energy Station Workshop

  15. Relocating a Cluster of Earthquakes Using a Single Seismic Station by David J. Robinson,*

    E-Print Network [OSTI]

    Snieder, Roel

    location accu- racy than determining whether an Mw 7.5 earthquake occurs offshore for tsunami warning on the application. For example, imaging the structure of a fracture system from microseismicity requires greater

  16. A continuous network location problem for a single refueling station Jose A. Ventura n

    E-Print Network [OSTI]

    Kincaid, Rex K.

    trucks are mainly powered by conventional fossil fuels such as gasoline or diesel. In order to respond to environmental and economic sustainability in the transportation sector, many logistics companies have a consider, or hydrogen [6,10,14,33]. For example, Fedex, one of the major logistics companies, plans to replace 30

  17. Grad Princeton Lakeside Lawrence Wegmans Walmart Trader Lawrence Lakeside Princeton College Station Apts Apts Joe's Apts Apts Station

    E-Print Network [OSTI]

    Rowley, Clarence W.

    Grad Princeton Lakeside Lawrence Wegmans Walmart Trader Lawrence Lakeside Princeton College Station:53 PM Grad Princeton Lakeside Lawrence Wegmans Walmart Trader Lawrence Lakeside Princeton College

  18. The Smithsonian Marine Station welcomes research scientists who wish to conduct studies at the Marine Station on a space-available basis. The following is a list of fees for laboratory space and use of Station

    E-Print Network [OSTI]

    Miller, Scott

    The Smithsonian Marine Station welcomes research scientists who wish to conduct studies at the Marine Station on a space-available basis. The following is a list of fees for laboratory space and use of Station equipment. Smithsonian Marine Station at Fort Pierce Fees for 2014 Tyson House lodging

  19. Modeling Advanced Neutron Source reactor station blackout accident using RELAP5

    SciTech Connect (OSTI)

    Chen, N.C.J. (Oak Ridge National Lab., TN (USA)); Fletcher, C.D. (EG and G Idaho, Inc., Idaho Falls, ID (USA))

    1990-01-01

    The Advanced Neutron Source (ANS) system model using RELAP5 has been developed to perform loss-of-coolant accident (LOCA) and non-LOCA transients as safety-related input for early design considerations. The transients studies include LOCA, station blackout, and reactivity insertion accidents. The small-, medium-, and large-break LOCA results were presented and documented. This paper will focus on the station blackout scenario. The station blackout analyses have concentrated on thermal-hydraulic system response with and without accumulators. Five transient calculations were performed to characterize system performance using various numbers and sizes of accumulators at several key sites. The main findings will be discussed with recommendations for conceptual design considerations. ANS is a state-of-the-art research reactor to be built and operated at high heat flux, high mass flux, and high coolant subcooling. To accommodate these features, three ANS-specific changes were made in the RELAP5 code by adding: the Petukhov heat transfer correlation for single-phase forced convection in the thin coolant channel; the Gambill additive method with the Weatherhead wall superheat for the critical heat flux; and the Griffith drift flux model for the interfacial drag in the slug flow regime. 7 refs., 6 figs., 1 tab.

  20. Evaluation of Station Post Porcelain Insulators with Room Temperature

    E-Print Network [OSTI]

    Evaluation of Station Post Porcelain Insulators with Room Temperature Vulcanized (RTV) Silicone to Engineer the Future Electric Energy System #12;Evaluation of Station Post Porcelain Insulators with Room and analysis of porcelain post insulators that were coated with a room temperature vulcanized (RTV) silicone

  1. General Information Relating to the Texas Agricultural Experiment Station

    E-Print Network [OSTI]

    Curtis, Geo. W. (George Washington)

    1891-01-01

    EXPERIMENT STATION. BULLETIN NO. 17. AUGUST, 1891. GENERAL INFORMATION RELATING TO THE n Texas Ae;ricuItural C Experiment Station: LAWS BUTFIORIZISG ESTABLISHPIIEKT; ORGANIZATIOS ASD OF- FICERS; RESULTS TO DATE; IITORK UNDER WAY; ISVENTORP.... ............................................... Horticultnrist. ................ n. ADRIAXCE, 31. S. .Meteorologist, Asst. Chemist. ............................. J. \\lt. C~RSON,. Assistant to Director. ........................... J. M. CARSOX.. .Assistant Agriculturist. ........... P. S. TILSON, B. S. A...

  2. Upcoming H2USA Workshop: Hydrogen Fueling Station Component Listings

    Broader source: Energy.gov [DOE]

    H2USA will host an online workshop about hydrogen fueling station component listings on April 22 from 2 to 3:30 p.m. Eastern Daylight Time. This workshop will focus on the need for components for hydrogen fueling stations to be listed by Nationally Recognized Testing Laboratories (NRTLs).

  3. DEVELOPMENT OF A TURNKEY COMMERCIAL HYDROGEN FUELING STATION

    E-Print Network [OSTI]

    NREL/CP-610-32405 #12;Approach Within this program, the development efforts are expected to build evaluations for each major sub-system in the Fueling Station will be completed. In Phase 2, sub-system R&D will be performed to test the concepts put forth in Phase 1. Also, the technical viability and Fueling Station costs

  4. Validation of an Integrated Hydrogen Energy Station

    SciTech Connect (OSTI)

    Edward C. Heydorn

    2012-10-26

    This report presents the results of a 10-year project conducted by Air Products and Chemicals, Inc. (Air Products) to determine the feasibility of coproducing hydrogen with electricity. The primary objective was to demonstrate the technical and economic viability of a hydrogen energy station using a high-temperature fuel cell designed to produce power and hydrogen. This four-phase project had intermediate go/no-go decisions and the following specific goals: �¢���¢ Complete a technical assessment and economic analysis of the use of high-temperature fuel cells, including solid oxide and molten carbonate, for the co-production of power and hydrogen (energy park concept). �¢���¢ Build on the experience gained at the Las Vegas H2 Energy Station and compare/contrast the two approaches for co-production. �¢���¢ Determine the applicability of co-production from a high-temperature fuel cell for the existing merchant hydrogen market and for the emerging hydrogen economy. �¢���¢ Demonstrate the concept on natural gas for six months at a suitable site with demand for both hydrogen and electricity. �¢���¢ Maintain safety as the top priority in the system design and operation. �¢���¢ Obtain adequate operational data to provide the basis for future commercial activities, including hydrogen fueling stations. Work began with the execution of the cooperative agreement with DOE on 30 September 2001. During Phase 1, Air Products identified high-temperature fuel cells as having the potential to meet the coproduction targets, and the molten carbonate fuel cell system from FuelCell Energy, Inc. (FuelCell Energy) was selected by Air Products and DOE following the feasibility assessment performed during Phase 2. Detailed design, construction and shop validation testing of a system to produce 250 kW of electricity and 100 kilograms per day of hydrogen, along with site selection to include a renewable feedstock for the fuel cell, were completed in Phase 3. The system also completed six months of demonstration operation at the wastewater treatment facility operated by Orange County Sanitation District (OCSD, Fountain Valley, CA). As part of achieving the objective of operating on a renewable feedstock, Air Products secured additional funding via an award from the California Air Resources Board. The South Coast Air Quality Management District also provided cost share which supported the objectives of this project. System operation at OCSD confirmed the results from shop validation testing performed during Phase 3. Hydrogen was produced at rates and purity that met the targets from the system design basis, and coproduction efficiency exceeded the 50% target set in conjunction with input from the DOE. Hydrogen production economics, updated from the Phase 2 analysis, showed pricing of $5 to $6 per kilogram of hydrogen using current gas purification systems. Hydrogen costs under $3 per kilogram are achievable if next-generation electrochemical separation technologies become available.

  5. Irradiation Environment of the Materials Test Station

    SciTech Connect (OSTI)

    Pitcher, Eric John

    2012-06-21

    Conceptual design of the proposed Materials Test Station (MTS) at the Los Alamos Neutron Science Center (LANSCE) is now complete. The principal mission is the irradiation testing of advanced fuels and materials for fast-spectrum nuclear reactor applications. The neutron spectrum in the fuel irradiation region of MTS is sufficiently close to that of fast reactor that MTS can match the fast reactor fuel centerline temperature and temperature profile across a fuel pellet. This is an important characteristic since temperature and temperature gradients drive many phenomena related to fuel performance, such as phase stability, stoichiometry, and fission product transport. The MTS irradiation environment is also suitable in many respects for fusion materials testing. In particular, the rate of helium production relative to atomic displacements at the peak flux position in MTS matches well that of fusion reactor first wall. Nuclear transmutation of the elemental composition of the fusion alloy EUROFER97 in MTS is similar to that expected in the first wall of a fusion reactor.

  6. Severe Accident Test Station Activity Report

    SciTech Connect (OSTI)

    Pint, Bruce A.; Terrani, Kurt A.

    2015-06-01

    Enhancing safety margins in light water reactor (LWR) severe accidents is currently the focus of a number of international R&D programs. The current UO2/Zr-based alloy fuel system is particularly susceptible since the Zr-based cladding experiences rapid oxidation kinetics in steam at elevated temperatures. Therefore, alternative cladding materials that offer slower oxidation kinetics and a smaller enthalpy of oxidation can significantly reduce the rate of heat and hydrogen generation in the core during a coolant-limited severe accident. In the U.S. program, the high temperature steam oxidation performance of accident tolerant fuel (ATF) cladding solutions has been evaluated in the Severe Accident Test Station (SATS) at Oak Ridge National Laboratory (ORNL) since 2012. This report summarizes the capabilities of the SATS and provides an overview of the oxidation kinetics of several candidate cladding materials. A suggested baseline for evaluating ATF candidates is a two order of magnitude reduction in the steam oxidation resistance above 1000ºC compared to Zr-based alloys. The ATF candidates are categorized based on the protective external oxide or scale that forms during exposure to steam at high temperature: chromia, alumina, and silica. Comparisons are made to literature and SATS data for Zr-based alloys and other less-protective materials.

  7. Conceptual design of a submerged power station

    SciTech Connect (OSTI)

    Herring, J.S. )

    1992-01-01

    Providing safe and sustainable energy to the world's increasing population will be one of the major challenges of the 21st century. Idaho National Engineering Laboratory is developing the concept of a submerged power stations (SPS). The reactor is located in the forward part of the vessel, while the turbine and generator are in the midsection, and the control and crew quarters are located at the opposite end of the vessel. The current design of the SPS has a 22.5-m o.d., is 146 m long, and has a total mass, including seawater in the annular region between the hulls, of 47,000 t. The SPS would be operated in 20 to 100 m of water at a distance of 10 to 30 km from the shore and would generate 300 to 600 MW(electric) transmitted to shore by undersea cables. The SPS has the advantages of centralized fabrication and maintenance. The author believes that the SPS has significant safety and environmental advantages.

  8. Economic Analysis of Hydrogen Energy Station Concepts: Are "H 2E-Stations" a Key Link to a Hydrogen Fuel Cell Vehicle Infrastructure?

    E-Print Network [OSTI]

    Lipman, Timothy E.; Edwards, Jennifer L.; Kammen, Daniel M.

    2002-01-01

    California location for the energy station concepts, and we include electricity and natural gas costs

  9. Solar-Assisted Electric Vehicle Charging Station Interim Report

    SciTech Connect (OSTI)

    Lapsa, Melissa Voss; Durfee, Norman; Maxey, L Curt; Overbey, Randall M

    2011-09-01

    Oak Ridge National Laboratory (ORNL) has been awarded $6.8 million in the Department of Energy (DOE) American Recovery and Reinvestment Act (ARRA) funds as part of an overall $114.8 million ECOtality grant with matching funds from regional partners to install 125 solar-assisted Electric Vehicle (EV) charging stations across Knoxville, Nashville, Chattanooga, and Memphis. Significant progress has been made toward completing the scope with the installation of 25 solar-assisted charging stations at ORNL; six stations at Electric Power Research Institute (EPRI); and 27 stations at Nissan's Smyrna and Franklin sites, with three more stations under construction at Nissan's new lithium-ion battery plant. Additionally, the procurement process for contracting the installation of 34 stations at Knoxville, the University of Tennessee Knoxville (UTK), and Nashville sites is underway with completion of installation scheduled for early 2012. Progress is also being made on finalizing sites and beginning installations of 30 stations in Nashville, Chattanooga, and Memphis by EPRI and Tennessee Valley Authority (TVA). The solar-assisted EV charging station project has made great strides in fiscal year 2011. A total of 58 solar-assisted EV parking spaces have been commissioned in East and Middle Tennessee, and progress on installing the remaining 67 spaces is well underway. The contract for the 34 stations planned for Knoxville, UTK, and Nashville should be underway in October with completion scheduled for the end of March 2012; the remaining three Nissan stations are under construction and scheduled to be complete in November; and the EPRI/TVA stations for Chattanooga, Vanderbilt, and Memphis are underway and should be complete by the end of March 2012. As additional Nissan LEAFs are being delivered, usage of the charging stations has increased substantially. The project is on course to complete all 125 solar-assisted EV charging stations in time to collect meaningful data by the end of government fiscal year 2012. Lessons learned from the sites completed thus far are being incorporated and are proving to be invaluable in completion of the remaining sites.

  10. Bridging the Gap Between Transportation and Stationary Power: Hydrogen Energy Stations and their Implications for the Transportation Sector

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Lipman, Timothy; Unnasch, Stephen

    2005-01-01

    and Stationary Power: Hydrogen Energy Stations and theirand Stationary Power: Hydrogen Energy Stations and their2004) for power parks & energy stations. (10) DESIGNS/

  11. Bridging the Gap Between Transportation and Stationary Power: Hydrogen Energy Stations and their Implications for the Transportation Sector

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Lipman, Timothy; Unnasch, Stephen

    2005-01-01

    Economic Analysis of Hydrogen Energy Station Concepts,E 2 Four Potential Types of Hydrogen Energy Stations VehicleOperational Toronto Hydrogen Energy Station Stationary PEMFC

  12. Envelope amplifier for broadband base-station envelope tracking power amplifier

    E-Print Network [OSTI]

    Zhu, Qiuyao

    2011-01-01

    Therefore, today’s base-station power amplifiers need to bethis chapter, the base-station power amplifier will be firstin section 1.3. Base-station Power Amplifiers Fig.1.1

  13. mathematics single cycle

    E-Print Network [OSTI]

    ?umer, Slobodan

    47 mathematics education single cycle master's study programme #12;48 single cycle master's study program in Mathematics Education #12;49 single cycle master's study program in Mathematics Education MATHEMATICS EDUCATION The program is in tune with the principles of the Bologna Declaration. · Academic title

  14. Buried waste integrated demonstration human engineered control station. Final report

    SciTech Connect (OSTI)

    Not Available

    1994-09-01

    This document describes the Human Engineered Control Station (HECS) project activities including the conceptual designs. The purpose of the HECS is to enhance the effectiveness and efficiency of remote retrieval by providing an integrated remote control station. The HECS integrates human capabilities, limitations, and expectations into the design to reduce the potential for human error, provides an easy system to learn and operate, provides an increased productivity, and reduces the ultimate investment in training. The overall HECS consists of the technology interface stations, supporting engineering aids, platform (trailer), communications network (broadband system), and collision avoidance system.

  15. SOARCA Peach Bottom Atomic Power Station Long-Term Station Blackout Uncertainty Analysis: Knowledge Advancement.

    SciTech Connect (OSTI)

    Gauntt, Randall O.; Mattie, Patrick D.; Bixler, Nathan E.; Ross, Kyle; Cardoni, Jeffrey N; Kalinich, Donald A.; Osborn, Douglas M.; Sallaberry, Cedric Jean-Marie; Ghosh, S. Tina

    2014-02-01

    This paper describes the knowledge advancements from the uncertainty analysis for the State-of- the-Art Reactor Consequence Analyses (SOARCA) unmitigated long-term station blackout accident scenario at the Peach Bottom Atomic Power Station. This work assessed key MELCOR and MELCOR Accident Consequence Code System, Version 2 (MACCS2) modeling uncertainties in an integrated fashion to quantify the relative importance of each uncertain input on potential accident progression, radiological releases, and off-site consequences. This quantitative uncertainty analysis provides measures of the effects on consequences, of each of the selected uncertain parameters both individually and in interaction with other parameters. The results measure the model response (e.g., variance in the output) to uncertainty in the selected input. Investigation into the important uncertain parameters in turn yields insights into important phenomena for accident progression and off-site consequences. This uncertainty analysis confirmed the known importance of some parameters, such as failure rate of the Safety Relief Valve in accident progression modeling and the dry deposition velocity in off-site consequence modeling. The analysis also revealed some new insights, such as dependent effect of cesium chemical form for different accident progressions. (auth)

  16. Survey Results and Analysis of the Cost and Efficiency of Various Operating Hydrogen Fueling Stations

    SciTech Connect (OSTI)

    Cornish, John

    2011-03-05

    Existing Hydrogen Fueling Stations were surveyed to determine capital and operational costs. Recommendations for cost reduction in future stations and for research were developed.

  17. Vision for Rollout of Fuel Cell Vehicles and Hydrogen Fuel Stations...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Vision for Rollout of Fuel Cell Vehicles and Hydrogen Fuel Stations Vision for Rollout of Fuel Cell Vehicles and Hydrogen Fuel Stations This document establishes the California...

  18. Where the Rubber Meets the Road-- the Alternative Fuel Station Locator

    Broader source: Energy.gov [DOE]

    To use the Alternative Fuel Station Locator, travelers with alternative fuel vehicles just enter their address alternative fuel station locator mobile and pick their fuel.

  19. Strategy for international cooperation in planning the Chinese Space Station

    E-Print Network [OSTI]

    Foley, Jordan J. (Jordan James)

    2014-01-01

    After ten years of planning and pre-development, the Chinese government approved the space station project on September 25, 2010. In October 2010, the People's Republic of China (PRC) officially announced its independent ...

  20. Optimal command generation for maneuvering the space station 

    E-Print Network [OSTI]

    Bryson, Amy Louise

    2001-01-01

    The objective of this research is to obtain near minimum-fuel and minimum-time maneuver commands for large-angle maneuvers for the international space station. Attitude and angular velocity waypoints are generated using the method of differential...

  1. Waiting for TOD : developing in the Millbrae BART Station Area

    E-Print Network [OSTI]

    Shih, Janet Wei

    2012-01-01

    The suburban terminus station dedicates large amounts of land for parking in order to cater to its driving riders, and causes a trade-off tension between attracting ridership through providing park-and-rides and building ...

  2. Enhancing the energy efficiency of radio base stations 

    E-Print Network [OSTI]

    Holtkamp, Hauke Andreas

    2014-06-30

    This thesis is concerned with the energy efficiency of cellular networks. It studies the dominant power consumer in future cellular networks, the Long Term Evolution (LTE) radio Base Station (BS), and proposes mechanisms ...

  3. Re: Potomac River Generating Station Department of Energy, Case...

    Office of Environmental Management (EM)

    2005 ("DOE Potomac River Order") Pepco hereby files this revised notice of the planned outage of the 230 kV circuits serving the Potomac River Substation, and through that station,...

  4. STDS08.COD: Climate Data from Weather Stations

    E-Print Network [OSTI]

    Whiting, John W. M.

    1986-01-01

    STDS08.COD: CLIMATE DATA FROM WEATHER STATIONS John W. M.84:279-298 (1982). The weather data are cited as coming fromFischer. Keywords: Climate. Weather. SCCS Codes. STDS08.CSV

  5. Development of a Turnkey Hydrogen Fueling Station Final Report

    SciTech Connect (OSTI)

    David E. Guro; Edward Kiczek; Kendral Gill; Othniel Brown

    2010-07-29

    The transition to hydrogen as a fuel source presents several challenges. One of the major hurdles is the cost-effective production of hydrogen in small quantities (less than 1MMscf/month). In the early demonstration phase, hydrogen can be provided by bulk distribution of liquid or compressed gas from central production plants; however, the next phase to fostering the hydrogen economy will likely include onsite generation and extensive pipeline networks to help effect a pervasive infrastructure. Providing inexpensive hydrogen at a fleet operator’s garage or local fueling station is a key enabling technology for direct hydrogen Fuel Cell Vehicles (FCVs). The objective of this project was to develop a comprehensive, turnkey, stand-alone, commercial hydrogen fueling station for FCVs with state-of-the-art technology that is cost-competitive with current hydrocarbon fuels. Such a station would promote the advent of the hydrogen fuel economy for buses, fleet vehicles, and ultimately personal vehicles. Air Products, partnering with the U.S. Department of Energy (DOE), The Pennsylvania State University, Harvest Energy Technology, and QuestAir, developed a turnkey hydrogen fueling station on the Penn State campus. Air Products aimed at designing a station that would have 65% overall station efficiency, 82% PSA (pressure swing adsorption) efficiency, and the capability of producing hydrogen at $3.00/kg (gge) H2 at mass production rates. Air Products designed a fueling station at Penn State from the ground up. This project was implemented in three phases. The first phase evaluated the various technologies available in hydrogen generation, compression, storage, and gas dispensing. In the second phase, Air Products designed the components chosen from the technologies examined. Finally, phase three entailed a several-month period of data collection, full-scale operation, maintenance of the station, and optimization of system reliability and performance. Based on field data analysis, it was determined by a proprietary hydrogen-analysis model that hydrogen produced from the station at a rate of 1500 kg/day and when produced at 1000 stations per year would be able to deliver hydrogen at a price of $3.03/kg (gge) H2. The station’s efficiency was measured to be 65.1%, and the PSA was tested and ran at an efficiency of 82.1%, thus meeting the project targets. From the study, it was determined that more research was needed in the area of hydrogen fueling. The overall cost of the hydrogen energy station, when combined with the required plot size for scaled-up hydrogen demands, demonstrated that a station using steam methane reforming technology as a means to produce on–site hydrogen would have limited utility in the marketplace. Alternative hydrogen supplies, such as liquid or pipeline delivery to a refueling station, need to be included in the exploration of alternative energy site layouts. These avenues need to be explored before a definitive refueling station configuration and commercialization pathway can be determined.

  6. Transfer stations and long-haul transport systems

    SciTech Connect (OSTI)

    Walsh, P.; Pferdehirt, W.; O'Leary, P. (Univ. of Wisconsin, Madison, WI (United States). Solid and Hazardous Waste Education Center)

    1993-12-01

    Transfer stations can be an important link between pickup at the curb and ultimate disposal, often allowing significant savings in the total costs to move wastes from the generator to the disposal site. A transfer station is simply a facility where collection trucks bring collected materials for loading into larger vehicles and subsequent shipment, usually to a landfill, waste-to-energy plant, or composting facility. Transferred wastes are typically shipped out in large trailers, but barges and railroad cars are also transport options. Although modern transfer stations usually include some provisions for handling recyclables, solid waste transfer dominates the operation of most facilities. Some communities have begun experimenting with transferring commingled, source-separated recyclables to regional processing centers. Transfer facilities can be as simple as a pavement slab and a front-end loader. Alternatively, transfer stations can cost millions of dollars and move thousands of tons of waste each day.

  7. Effective Load Management for the City of College Station 

    E-Print Network [OSTI]

    Hecox, O. D.; Bauer, V.

    1985-01-01

    A successful electrical demand management program for the City of College Station in 1984 employed techniques proven in the industrial and commercial sectors that have seldom been used at the community level. The program, with technical assistance...

  8. Determination of station blackout frequency-duration relationships

    SciTech Connect (OSTI)

    Griggs, D.P.; Riggs, B.K.; Balakrishna, S.

    1986-01-01

    Station blackout is the loss of all alternating current (ac) power to the essential and nonessential electrical buses in a nuclear power plant. This generally involves the loss of redundant off-site power sources and the failure of two or more emergency diesel generators (EDGs). The US Nuclear Regulatory Commission (NRC) has proposed requiring all commercial reactors to have the capability of coping with a station blackout of a specified duration. The NRC has also proposed 4 or 8 h as acceptable durations, depending on plant susceptibility to the occurrence of station blackout events. Analyses were performed to determine expected station blackout frequencies representative of a majority of domestic nuclear power plants. A methodology based on that developed by the NRC was used. Representative industry data for loss of off-site power (LOOP) events and EDG reliability were used in the analyses.

  9. Field Stations Compliance CommitteesAdministrative Units Research Units

    E-Print Network [OSTI]

    Alvarez-Cohen, Lisa

    of the Environment Berkeley Nanosciences & Nanoengineering Institute California Institute for Energy for the Study of Sexual Culture Center for Tebtunis Papyri Energy Biosciences Institute (EBI) Field Station & Social Research Institute of Slavic, East European, and Eurasian Studies Institute of Transportation

  10. (Survey of three isolated diesel power stations in Guatemala)

    SciTech Connect (OSTI)

    Chronowski, R.A.

    1990-03-15

    I traveled to Guatemala City, Guatemala to participate with a team of specialists to study the operating, administrative, and management efficiency of isolated diesel power plants, operated by Instituto Nacional de Electrificacion (INDE). The study is part of a global initiative managed jointly by the Agency for International Development and the World Bank. The power plants were audited, including INDE's largest isolated diesel station, and two much smaller municipal and privately owned stations. I returned to the USA on February 20, 1990.

  11. Southwest Region Experiment Station - Final Technical Report

    SciTech Connect (OSTI)

    Rosenthal, A

    2011-08-19

    Southwest Technology Development Institute (SWTDI), an independent, university-based research institute, has been the operator of the Southwest Region Photovoltaic Experiment Station (SWRES) for almost 30 years. The overarching mission of SWTDI is to position PV systems and solar technologies to become cost-effective, major sources of energy for the United States. Embedded in SWTDI's general mission has been the more-focused mission of the SWRES: to provide value added technical support to the DOE Solar Energy Technologies Program (SETP) to effectively and efficiently meet the R&D needs and targets specified in the SETP Multi-Year Technical Plan. : The DOE/SETP goals of growing U.S. PV manufacturing into giga-watt capacities and seeing tera-watt-hours of solar energy production in the U.S. require an infrastructure that is under development. The staff of the SWRES has supported DOE/SETP through a coherent, integrated program to address infrastructural needs inhibiting wide-scale PV deployment in three major technical categories: specialized engineering services, workforce development, and deployment facilitation. The SWRES contract underwent three major revisions during its five year period-of- performance, but all tasks and deliverables fell within the following task areas: Task 1: PV Systems Assistance Center 1. Develop a Comprehensive multi-year plan 2. Provide technical workforce development materials and workshops for PV stakeholder groups including university, professional installers, inspectors, state energy offices, Federal agencies 3. Serve on the NABCEP exam committee 4. Provide on-demand technical PV system design reviews for U.S. PV stakeholders 5. Provide PV system field testing and instrumentation, technical outreach (including extensive support for the DOE Market Transformation program) Task 2: Design-for-Manufacture PV Systems 1. Develop and install 18 kW parking carport (cost share) and PV-thermal carport (Albuquerque) deriving and publishing lessons learned Task 3: PV Codes and Standards 1. Serve as the national lead for development and preparation of all proposals (related to PV) to the National Electrical Code 2. Participate in the Standards Technical Panels for modules (UL1703) and inverters (UL1741) Task 4: Assess Inverter Long Term Reliability 1. Install and monitor identical inverters at SWRES and SERES 2. Operate and monitor all inverters for 5 years, characterizing all failures and performance trends Task 5: Test and Evaluation Support for Solar America Initiative 1. Provide test and evaluation services to the National Laboratories for stage gate and progress measurements of SAI TPP winners

  12. An Intelligent Solar Powered Battery Buffered EV Charging Station with Solar Electricity Forecasting and EV Charging Load Projection Functions

    E-Print Network [OSTI]

    Zhao, Hengbing; Burke, Andrew

    2014-01-01

    eliminate the charging station peak power demand for EVcan lower the station’s peak power demand and reduce thefor a workplace charging station, solar PV power cannot be

  13. Uncertainties in source term estimates for a station blackout accident in a BWR with Mark I containment

    SciTech Connect (OSTI)

    Lee, M.; Cazzoli, E.; Liu, Y.; Davis, R.; Nourbakhsh, H.; Schmidt, E.; Unwin, S.; Khatib-Rahbar, M.

    1988-01-01

    In this paper, attention is limited to a single accident progression sequence, namly a station blackout accident in a BWR with a Mark I containment building. Identified as an important accident in the draft version of NUREG-1150 a station blackout involves loss of both off-site power and dc power resulting in failure of the diesels to start and in the unavailability of the high pressure injection and core isolation cooling systems. This paper illustrates the calculated uncertainties (Probability Density Functions) associated with the radiological releases into the environment for the nine fission product groups at 10 hours following the initiation of core-concrete interactions. Also shown are the results ofthe STCP base case simulation. 5 refs., 1 fig., 1 tab.

  14. ARM: Broadband Radiometer Station (BRS) broadband shortwave and longwave 1-min radiation data with Dutton correction

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Laura Riihimaki

    1993-09-01

    Broadband Radiometer Station (BRS) broadband shortwave and longwave 1-min radiation data with Dutton correction

  15. Power-Optimal Scheduling for a Green Base Station with Delay Constraints

    E-Print Network [OSTI]

    Sharma, Vinod

    Power-Optimal Scheduling for a Green Base Station with Delay Constraints Anusha Lalitha, Santanu with average delay constraint on the downlink of a Green Base- station. A Green Base-station is powered by both Terms--Power-optimal, Green Base station, Delay con- straint, multi-user. I. INTRODUCTION The main

  16. Planning and Installation Guide: North Carolina Compressed Natural Gas Fueling Stations

    E-Print Network [OSTI]

    Introduction Are you considering installing a compressed natural gas (CNG) fueling station for your fleet of important items to consider when planning for a CNG station. Natural gas infrastructure, which is commonly - Others interested in installing a natural gas fueling station CNG fueling station under construction

  17. ARM: Broadband Radiometer Station (BRS) broadband shortwave and longwave 1-min radiation data with Dutton correction

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Laura Riihimaki

    Broadband Radiometer Station (BRS) broadband shortwave and longwave 1-min radiation data with Dutton correction

  18. AEC Lowman Station - coal switching and magnesium-enhanced lime scrubbing to lower operating costs

    SciTech Connect (OSTI)

    Inkenhaus, W.; Babu, M.; Smith, K. [Dravo Lime Co., Pittsburgh, PA (United States); Loper, L. [Alabama Electric Coopreative, Leroy, AL (United States)

    1997-12-31

    AEC`s Lowman Station is located in Leroy, Alabama. There are three coal-fired boilers at this station. Unit 1 is capable of generating 85 MW without a flue gas desulfurization, FGD, system. Units 2 and 3, with a total of 516 MW output capacity, are equipped with FGD systems. The FGD plant was designed for wet limestone FGD with natural oxidation. Lowman Station burned low sulfur, 1.3 to 1.8% sulfur, coal. In January of 1996 AEC switched Units 2 and 3 from limestone to magnesium-enhanced lime FGD operation. It was determined that the plant could take advantage of the higher SO{sub 2} removal efficiency of the magnesium-enhanced lime system. Major benefits resulting from this conversion were AEC`s ability to switch to a lower cost high sulfur coal while meeting the stringent SO{sub 2} emission requirements. Power cost savings resulted from the lower liquid to gas ratio required by the magnesium-enhanced lime process. Three recirculation pumps per module were reduced to a single operating pump per module, lowering the scrubber pressure drop. Significant cost reduction in the operating costs of the ball mill was realized due to modifications made to slake lime instead of grinding limestone. Prior to switching, personnel from AEC and Dravo Lime Company ran a four week test on magnesium-enhanced lime to obtain scrubber performance data including SO{sub 2} removal efficiencies on the modules while burning a 1.8% sulfur coal. This paper discusses the plant modifications that were needed to make the switch, cost justifications due to coal switching, and AEC`s operating experiences to date. AEC and Dravo Lime Company working together as a team conducted detailed cost studies, followed by extensive field tests and implemented the plant modifications. This plant continues to operate burning higher sulfur coal with the magnesium-enhanced lime FGD system.

  19. Loss of pressurizer water level during station blackout

    SciTech Connect (OSTI)

    Griggs, D.P.; Riggs, B.K.

    1986-01-01

    Station blackout is the loss of all alternating current (ac) power to both the essential and nonessential electrical buses in a nuclear power plant. The US Nuclear Regulatory Commission (NRC) has proposed a requirement that all plants be capable of maintaining adequate core cooling during station blackout events lasting a specified duration. The NRC has also suggested acceptable specified durations of four or eight hours, depending on individual plant susceptibility to blackout events. In a pressurized water reactor (PWR), the occurrence of a station blackout event results in the functional loss of many plant components, including main feedwater, reactor coolant pumps, the emergency core cooling system, and pressurizer heaters and spray. Nevertheless, PWRs have the capability of removing decay heat for some period of time using steam-driven auxiliary feedwater pumps and the natural-circulation capability of the primary system. The purpose of this investigation is to determine the early response of a PWR to station blackout conditions. In particular, the effect of primary coolant shrinkage and inventory loss on pressurizer level is examined to gain insight into the operational and analytical issues associated with the proposed station blackout coping requirement.

  20. PV powering a weather station for severe weather

    SciTech Connect (OSTI)

    Young, W. Jr. [Florida Solar Energy Center, Cocoa, FL (United States); Schmidt, J. [Joe Schmidt, Inc., Miami, FL (United States)

    1997-12-31

    A natural disaster, such as Hurricane Andrew, destroys thousands of homes and businesses. The destruction from this storm left thousands of people without communications, potable water, and electrical power. This prompted the Florida Solar Energy Center to study the application of solar electric power for use in disasters. During this same period, volunteers at the Tropical Prediction Center at the National Hurricane Center (NHC), Miami, Florida and the Miami Office of the National Weather Service (NWS) were working to increase the quantity and quality of observations received from home weather stations. Forecasters at NHC have found surface reports from home weather stations a valuable tool in determining the size, strength and course of hurricanes. Home weather stations appear able to record the required information with an adequate level of accuracy. Amateur radio, utilizing the Automatic Packet Report System, (APRS) can be used to transmit this data to weather service offices in virtually real time. Many weather data collecting stations are at remote sites which are not readily serviced by dependable commercial power. Photovoltaic (solar electric) modules generate electricity and when connected to a battery can operate as a stand alone power system. The integration of these components provides an inexpensive standalone system. The system is easy to install, operates automatically and has good communication capabilities. This paper discusses the design criteria, operation, construction and deployment of a prototype solar powered weather station.

  1. Locating PHEV Exchange Stations in V2G

    E-Print Network [OSTI]

    Pan, Feng; Berscheid, Alan; Izraelevitz, David

    2010-01-01

    Plug-in hybrid electric vehicles (PHEVs) are an environmentally friendly technology that is expected to rapidly penetrate the transportation system. Renewable energy sources such as wind and solar have received considerable attention as clean power options for future generation expansion. However, these sources are intermittent and increase the uncertainty in the ability to generate power. The deployment of PHEVs in a vehicle-to-grid (V2G) system provide a potential mechanism for reducing the variability of renewable energy sources. For example, PHEV supporting infrastructures like battery exchange stations that provide battery service to PHEV customers could be used as storage devices to stabilize the grid when renewable energy production is fluctuating. In this paper, we study how to best site these stations in terms of how they can support both the transportation system and the power grid. To model this problem we develop a two-stage stochastic program to optimally locate the stations prior to the realizat...

  2. EIS-0210: Tampa Electric Company-Polk Power Station (Adopted)

    Broader source: Energy.gov [DOE]

    The U.S. Environmental Protection Agency prepared this statement to fulfill its National Environmental Policy Act requirements with respect to the potential issuance of a permit to the Tampa Electric Company under the National Pollutant Discharge Elimination System for the 1,150-MW Polk Power Station, a new pollutant source. The U.S. Department of Energy served as a cooperating agency in the development of this document due to its potential role to provide cost-shared financial assistance for a 260-MW Integrated Gasification Combined Cycle unit at the Power Station under its Clean Coal Technology Demonstration Project, and adopted the document by August 1994.

  3. Design of photovoltaic central power station concentrator array

    SciTech Connect (OSTI)

    Not Available

    1984-02-01

    A design for a photovoltaic central power station using tracking concentrators has been developed. The 100 MW plant is assumed to be located adjacent to the Saguaro Power Station of Arizona Public Service. The design assumes an advanced Martin Marietta two-axis tracking fresnel lens concentrator. The concentrators are arrayed in 5 MW subfields, each with its own power conditioning unit. The photovoltaic plant output is connected to the existing 115 kV switchyard. The site specific design allows detailed cost estimates for engineering, site preparation, and installation. Collector and power conditioning costs have been treated parametrically.

  4. Characterization of ash cenospheres in fly ash from Australian power stations

    SciTech Connect (OSTI)

    Ling-ngee Ngu; Hongwei Wu; Dong-ke Zhang

    2007-12-15

    Ash cenospheres in fly ashes from five Australian power stations have been characterized. The experimental data show that ash cenosphere yield varies across the power stations. Ash partitioning occurred in the process of ash cenosphere formation during combustion. Contradictory to conclusions from the literature, iron does not seem to be essential to ash cenosphere formation in the cases examined in the present work. Further investigation was also undertaken on a series of size-fractioned ash cenosphere samples from Tarong power station. It is found that about 70 wt% of ash cenospheres in the bulk sample have sizes between 45 and 150 {mu}m. There are two different ash cenosphere structures, that is, single-ring structure and network structure. The percentage of ash cenospheres of a network structure increases with increasing ash cenosphere size. Small ash cenospheres (in the size fractions {lt}150 {mu}m) have a high SiO{sub 2}/Al{sub 2}O{sub 3} ratio, and the majority of the ash cenospheres are spherical and of a single-ring structure. Large ash cenosphere particles (in the size fractions of 150-250 {mu}m and {gt}250 {mu}m) have a low SiO{sub 2}/Al{sub 2}O{sub 3} ratio, and a high proportion of the ash cenospheres are nonspherical and of a network structure. A novel quantitative technique has been developed to measure the diameter and wall thickness of ash cenospheres on a particle-to-particle basis. A monolayer of size-fractioned ash cenospheres was dispersed on a pellet, which was then polished carefully before being examined using a scanning electron microscope and image analysis. The ash cenosphere wall thickness broadly increases with increasing ash cenosphere size. The ratios between wall thickness and diameter of ash cenospheres are limited between an upper bound of about 10.5% and a lower bound of about 2.5%, irrespective of the ash cenosphere size. 52 refs., 9 figs., 4 tabs.

  5. Single casing reheat turbine

    SciTech Connect (OSTI)

    Matsushima, Tatsuro; Nishimura, Shigeo

    1999-07-01

    For conventional power plants, regenerative reheat steam turbines have been accepted as the most practical method to meet the demand for efficient and economical power generation. Recently the application of reheat steam turbines for combined cycle power plant began according to the development of large-capacity high temperature gas turbine. The two casing double flow turbine has been applied for this size of reheat steam turbine. The single casing reheat turbine can offer economical and compact power plant. Through development of HP-LP combined rotor and long LP blading series, Mitsubishi Heavy Industries, Ltd. had developed a single casing reheat steam turbine series and began to use it in actual plants. Six units are already in operation and another seven units are under manufacturing. Multiple benefits of single casing reheat turbine are smaller space requirements, shorter construction and erection period, equally good performance, easier operation and maintenance, shorter overhaul period, smaller initial investment, lower transportation expense and so on. Furthermore, single exhaust steam turbine makes possible to apply axial exhaust type, which will lower the height of T/G foundation and T/G housing. The single casing reheat turbine has not only compact and economical configuration itself but also it can reduce the cost of civil construction. In this paper, major developments and design features of the single casing reheat turbine are briefly discussed and operating experience, line-up and technical consideration for performance improvement are presented.

  6. Source terms released into the environment for a station blackout severe accident at the Peach Bottom Atomic Power Station

    SciTech Connect (OSTI)

    Carbajo, J.J.

    1995-07-01

    This study calculates source terms released into the environment at the Peach Bottom Atomic Power Station after containment failure during a postulated low-pressure, short-term station blackout severe accident. The severe accident analysis code MELCOR, version 1.8.1, was used in these calculations. Source terms were calculated for three different containment failure modes. The largest environmental releases occur for early containment failure at the drywell liner in contact with the cavity by liner melt-through. This containment failure mode is very likely to occur when the cavity is dry during this postulated severe accident sequence.

  7. The PICO-NARE Station Project Description and Initial Observations

    E-Print Network [OSTI]

    Honrath, Richard E.

    that air qual- ity measurements at Pico are needed, and Section 3 de- scribes the station itself. Initial.S. National Oceanic and Atmospheric Administration Portugal Foundation for Science and Technology U.S. Air was developed to study the impacts that air pollutant emissions from the surrounding continents have

  8. Colorado State University, Fort Collins, CO Weather Station

    E-Print Network [OSTI]

    normal (151% of normal). This remains the 3rd snowiest season (Sept-June) in the 122 year record. The topColorado State University, Fort Collins, CO Weather Station Monthly Summary Report Month: June Year for the month. This ranks as the 29th warmest in the 122 year record (1889-2010). The most recent year

  9. Mississippi Agricultural and Forestry Experiment Station Vehicle Rental Request Form

    E-Print Network [OSTI]

    Ray, David

    Mississippi Agricultural and Forestry Experiment Station Vehicle Rental Request Form Driver Name Date: Travel Destination: Account #: Vehicle Information 1995 Crown Victoria 1995 Crown Victoria 1995 with the MSU Authorized Vehicle Use Policy. You further acknowledge that you have executed the Mississippi

  10. Warkworth 12m VLBI Station: WARK12M - 2014

    E-Print Network [OSTI]

    Weston, Stuart; Woodburn, Lewis; Hart, Ben; Gulyaev, Sergei

    2015-01-01

    The Warkworth Radio Astronomical Observatory is operated by the Institute for Radio Astronomy and Space Research (IRASR), AUT University, Auckland, New Zealand. Here we review the characteristics of the VLBI station facilities and report on a number of activities and technical developments in 2014.

  11. Neutrinos from Stored Muons STORM Target Station Conceptualg p

    E-Print Network [OSTI]

    McDonald, Kirk

    beamline chase with adequate shielding · Active beamline elements include: - Production target Focusing Supply Lines OOuter Conductor Water Scavenge Tank #12;STORM Target Station Conceptual Design Approach techniques T h hi ldi l ld b l i· Target chase shielding steel would be mostly comprise of relatively

  12. Achieving High Chilled Water Delta T Without Blending Station 

    E-Print Network [OSTI]

    Wang, Z.; Wang, G.; Xu, K.; Yu, Y.; Liu, M.

    2007-01-01

    Typically a blending station is designed to ensure that its user is able to avoid low chilled water return temperature in the district cooling system. When the chilled water return temperature drops to a low limit, building return water is blended...

  13. Station GPS permanente IPG Paris DGF Uchile UNAP Iquique

    E-Print Network [OSTI]

    Vigny, Christophe

    NetRS, Antenna TRIMBLE Zephyr geodetic and autonomous energy (battery and solar panel). HISTORIC Semi.71476292 - 69.82727839 1675.36 DESCRIPTION North Chile II region, semi-permanent GPS station IPGP / DGF network in the nature telephone nearby NONO Electric power nearby NONO equipment storage available YESYES possibility

  14. Station GPS permanente IPG Paris DGF Uchile UNAP Iquique

    E-Print Network [OSTI]

    Vigny, Christophe

    -glue. Receptor TRIMBLE NetRS, Antenna TRIMBLE Zephyr geodetic and autonomous energy (battery and solar panel IPGP / DGF network installed during Dec- 2007. MONUMENTATION Station located in the coastal platform nearby NONO Electric power nearby NONO equipment storage available YESYES possibility of leaving

  15. Tampa Electric Company Polk Power Station IGCC Project -- Project status

    SciTech Connect (OSTI)

    Berry, T.E.

    1998-12-31

    The Tampa Electric Company Polk Power Station is a nominal 25 MW (net) Integrated Gasification Combined Cycle (IGCC) power plant located southeast of Tampa in Polk County, Florida. This project is being partially funded under the Department of Energy`s Clean Coal Technology Program pursuant to a Round III award. The Polk Power Station uses oxygen-blown, entrained-flow coal gasification technology licensed from Texaco Development Corporation in conjunction with a General Electric combined cycle with an advanced combustion turbine. This IGCC configuration demonstrates significant reductions of SO{sub 2} and NOx emissions when compared to existing and future conventional coal-fired power plants. The Polk Power Station achieved ``first fire`` of the gasification system on schedule in mid-July, 1996. It was placed into commercial operation on September 30, 1996. Since that time, significant advances have occurred in the operation of the entire IGCC train. The presentation features an up-to-the-minute update of actual performance parameters achieved by the Polk Power Station. These parameters include overall capacity, heat rate, and availability. Tests of four alternate feedstocks were conducted, and the resulting performance is compared to that achieved on their base coal. This paper also provides an update of the general operating experiences and shutdown causes of the gasification facility throughout 1997. Finally, the future plans for improving the reliability and efficiency of the Unit will be addressed, as well as plans for future additional alternate fuel test burns.

  16. Tampa Electric Company, Polk Power Station IGCC Project: Project Status

    SciTech Connect (OSTI)

    Berry, T.E.; Shelnut, C.A.; McDaniel, J.E.

    1999-07-01

    Over the last ten years, Tampa Electric Company (TEC) has taken the Polk Power Station from a concept to a reality. The Tampa Electric Company Polk Power Station is a nominal 250 MW (net) Integrated Gasification Combined Cycle (IGCC) power plant located to the southeast of Tampa, Florida in Polk County, Florida. This project is being partially funded under the Department of Energy Clean Coal Technology Program pursuant to a Round III award. The Polk Power Station achieved first fire of the gasification system on schedule in mid-July, 1996. It was placed in commercial operation on September 30, 1996. Since start-up in July, 1996, significant advances have occurred in the design and operation of the entire IGCC train. This presentation will feature an up-to-the-minute update of actual performance parameters achieved by the Polk Power Station. These parameters include overall capacity, heat rate, and availability. Several different coal feedstocks have been tested and the resulting performance will be compared to that achieved on the base coal. This paper also provides an update of the general operating experiences and shutdown causes of the gasification facility. Finally, the future plans for improving the reliability and efficiency of the Unit will be addressed, as well as plans for future additional alternate fuel test burns.

  17. Daily temperature and precipitation data for 223 USSR Stations

    SciTech Connect (OSTI)

    Razuvaev, V.N.; Apasova, E.G.; Martuganov, R.A.; Vose, R.S.; Steurer, P.M.

    1993-11-01

    On- May 23, 1972, the United States and the USSR established a bilateral initiative known as the Agreement on Protection of the Environment. Given recent interest in possible greenhouse gas-induced climate change, Working Group VIII (Influence of Environmental Changes on Climate) has become particularly useful to the scientific communities of both nations. Among its many achievements, Working Group VIII has been instrumental in the exchange of climatological information between the principal climate data centers of each country [i.e., the National Climatic Data Center (NCDC) in Asheville, North Carolina, and the Research Institute of Hydrometeorological Information in Obninsk, Russia]. Considering the relative lack of climate records previously available for the USSR, data obtained via this bilateral exchange are particularly valuable to researchers outside the former Soviet Union. To expedite the dissemination of these data, NOAA`s Climate and Global Change Program funded the Carbon Dioxide Information Analysis Center (CDIAC) and NCDC to distribute one of the more useful archives acquired through this exchange: a 223-station daily data set covering the period 1881-1989. This data set contains: (1) daily mean, minimum, and maximum temperature data; (2) daily precipitation data; (3) station inventory information (WMO No., name, coordinates, and elevation); (4) station history information (station relocation and rain gauge replacement dates); and (5) quality assurance information (i.e., flag codes that were assigned as a result of various data checks). The data set is available, free of charge, as a Numeric Data Package (NDP) from CDIAC. The NDP consists of 18 data files and a printed document which describes both the data files and the 223-station network in detail.

  18. A Clustering Approach to Planning Base Station and Relay Station Locations in IEEE 802.16j Multi-hop

    E-Print Network [OSTI]

    Murphy, Liam

    can be developed at significantly lower cost than Base Stations (BSs). This standard is expected not yet occurred, providing a lower cost coverage solution is very attractive. While relay technologies are in their early stages. The community is an area which continues to innovate in many ways, one of which

  19. Single Atom Plasmonic Switch

    E-Print Network [OSTI]

    Emboras, Alexandros; Ma, Ping; Haffner, Christian; Luisier, Mathieu; Hafner, Christian; Schimmel, Thomas; Leuthold, Juerg

    2015-01-01

    The atom sets an ultimate scaling limit to Moores law in the electronics industry. And while electronics research already explores atomic scales devices, photonics research still deals with devices at the micrometer scale. Here we demonstrate that photonic scaling-similar to electronics-is only limited by the atom. More precisely, we introduce an electrically controlled single atom plasmonic switch. The switch allows for fast and reproducible switching by means of the relocation of an individual or at most - a few atoms in a plasmonic cavity. Depending on the location of the atom either of two distinct plasmonic cavity resonance states are supported. Experimental results show reversible digital optical switching with an extinction ration of 10 dB and operation at room temperature with femtojoule (fJ) power consumption for a single switch operation. This demonstration of a CMOS compatible, integrated quantum device allowing to control photons at the single-atom level opens intriguing perspectives for a fully i...

  20. Single-exciton nanocrystal laser

    DOE Patents [OSTI]

    Klimov, Victor I. (Los Alamos, NM); Ivanov, Sergei A. (Albuquerque, NM)

    2012-01-17

    A laser system employing amplification via a single exciton regime and to optical gain media having single exciton amplification is provided.

  1. Single crystalline mesoporous silicon nanowires

    E-Print Network [OSTI]

    Hochbaum, A.I.

    2010-01-01

    effects in highly porous crystalline silicon, Nature 1991,J. , Fabrication of single-crystalline silicon nanowires bySingle crystalline mesoporous silicon nanowires Allon I.

  2. Single crystalline mesoporous silicon nanowires

    E-Print Network [OSTI]

    Hochbaum, Allon

    2010-01-01

    Quantum Dots: A General crystalline silicon, Nature 1991,1998, 31, 1927-1949. single-crystalline silicon nanowires byof their facilities. Single crystalline mesoporous silicon

  3. AVTA: GE Energy WattStation AC Level 2 Charging System Testing...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy WattStation AC Level 2 Charging System Testing Results AVTA: GE Energy WattStation AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced...

  4. Fact #832: August 4, 2014 Over Half of the Refueling Stations...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2: August 4, 2014 Over Half of the Refueling Stations in the U.S. and Canada Sell Diesel Fuel Fact 832: August 4, 2014 Over Half of the Refueling Stations in the U.S. and Canada...

  5. Fact #717: March 5, 2012 Availability of Electric Charging Stations Has Increased Dramatically in Recent Years

    Broader source: Energy.gov [DOE]

    At the end of September 2009, there were just 465 electric vehicle charging stations nationwide. By the end of January 2012, the number of charging stations had grown to 6,033. California has...

  6. Tri-Generation Success Story: World's First Tri-Gen EnergyStation...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Tri-Generation Success Story: World's First Tri-Gen Energy Station-Fountain Valley Tri-Generation Success Story: World's First Tri-Gen Energy Station-Fountain Valley This Fuel Cell...

  7. Fact #874: May 25, 2015 Number of Electric Stations and Electric Charging Units Increasing

    Office of Energy Efficiency and Renewable Energy (EERE)

    There are more electric stations than any other alternative fuel (10,710 stations). The number of charging units is of particular importance for electric vehicles due to the length of time it takes...

  8. Fact #816: February 10, 2014 Natural Gas Refueling Stations Grow Over the Last Ten Years

    Broader source: Energy.gov [DOE]

    In 2003 there were 1,097 natural gas refueling stations nationwide. By 2013, that number increased by about 25% to a total of 1,374 natural gas refueling stations. In 2003, there were six states...

  9. Thermal Characteristics and Systems of Residential Construction in College Station, Texas: 1981-1986 

    E-Print Network [OSTI]

    Claridge, D. E.; Neidinger, P.; Schrock, D.

    1987-01-01

    This paper examines the energy efficiency of residential construction in College Station from 1981-1986. Housing sizes, location, and construction activity by various contractors are described using data summarized from the College Station building...

  10. Report of the Director on the Establishment of the New State Stations

    E-Print Network [OSTI]

    Harrington, H. H. (Henry Hill)

    1910-01-01

    ................................................... ................................................... JAMES CRAYENS Houston f' ................................................ WALTON PETEET F ort Worth E. R. KOKE ......................................................... ustin .................................................... A. R. MCCOLLUII Wac0... ............................................ W. P. SERASTIAR-. Breckenridge I President of College. \\ ............................. ............ R. T. MILNER.. ;. .College Station Station Officers. i ............................................... H. H. HARRTSGTOS .Director...

  11. World's First Tri-Generation Fuel Cell and Hydrogen Fueling Station...

    Energy Savers [EERE]

    World's First Tri-Generation Fuel Cell and Hydrogen Fueling Station World's First Tri-Generation Fuel Cell and Hydrogen Fueling Station April 18, 2013 - 12:00am Addthis EERE...

  12. Hydrogen Energy Stations: Poly-Production of Electricity, Hydrogen, and Thermal Energy

    E-Print Network [OSTI]

    Lipman, Timothy; Brooks, Cameron

    2006-01-01

    the potential of hydro- gen energy stations as a source ofVegas energy station that has a lower electricity to hydro-hydro- gen roadmap” in an effort led by the New York State Energy

  13. NuMI Target Station AHIPA09 10/19/09

    E-Print Network [OSTI]

    McDonald, Kirk

    MI Target Station AHIPA09 10/19/09 Jim Hylen/FNAL Page 11Remote 5-axis lift table Numi target+baffle on liftNuMI Target Station AHIPA09 10/19/09 Jim Hylen/FNAL Page 1 Target Station Infrastructure: The Nu slide overview of NuMI #12;NuMI Target Station AHIPA09 10/19/09 Jim Hylen/FNAL Page 2 NuMI produces

  14. SNL Issues a Request for Quotation for a Hydrogen Station Test Device

    Broader source: Energy.gov [DOE]

    Sandia National Laboratories (SNL) has issued a Request for Quotation (RFQ) for hydrogen station equipment performance testing device fabrication.

  15. Navajo Generating Station and Air Visibility Regulations: Alternatives and Impacts

    SciTech Connect (OSTI)

    Hurlbut, D. J.; Haase, S.; Brinkman, G.; Funk, K.; Gelman, R.; Lantz, E.; Larney, C.; Peterson, D.; Worley, C.; Liebsch, E.

    2012-01-01

    Pursuant to the Clean Air Act, the U.S. Environmental Protection Agency (EPA) announced in 2009 its intent to issue rules for controlling emissions from Navajo Generating Station that could affect visibility at the Grand Canyon and at several other national parks and wilderness areas. The final rule will conform to what EPA determines is the best available retrofit technology (BART) for the control of haze-causing air pollutants, especially nitrogen oxides. While EPA is ultimately responsible for setting Navajo Generating Station's BART standards in its final rule, it will be the U.S. Department of the Interior's responsibility to manage compliance and the related impacts. This study aims to assist both Interior and EPA by providing an objective assessment of issues relating to the power sector.

  16. stations PLIG and YAIG displays the same symmetries as the theoretical Green tensor

    E-Print Network [OSTI]

    Cohen, Barbara Anne

    that is generated repeatedly at the coast by the conversion of oceanic waves and that propagates in the direction station PLIG and station YAIG, there is a preferential direc- tion of transport of diffuse energy- ered a couple of stations along the coast (fig. S2A) for which the distribution of epicenters is more

  17. THE ELECTRIC VEHICLE CHARGING STATION LOCATION PROBLEM: A PARKING-BASED ASSIGNMENT METHOD FOR SEATTLE

    E-Print Network [OSTI]

    Kockelman, Kara M.

    ABSTRACT Access to electric vehicle (EV) charging stations will impact EV adoption rates, use decisions programming problem, developed here for optimal EV-charging-station location assignments. The algorithm As electric vehicles (EVs) enter the market, there is rising demand for public charging stations

  18. Aalborg Universitet Two-Level Control for Fast Electrical Vehicle Charging Stations with Multi Flywheel

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    . Keywords--EV charging station; flywheel energy storage system; distributed bus signaling I. INTRODUCTIONAalborg Universitet Two-Level Control for Fast Electrical Vehicle Charging Stations with Multi Vehicle Charging Stations with Multi Flywheel Energy Storage System. In IEEE ICDCM 2015. IEEE. General

  19. Aalborg Universitet Reactive Power Support of Electrical Vehicle Charging Station Upgraded with Flywheel

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Aalborg Universitet Reactive Power Support of Electrical Vehicle Charging Station Upgraded of Electrical Vehicle Charging Station Upgraded with Flywheel Energy Storage System," in Proc. IEEE PowerTech, 2015. Reactive Power Support of Electrical Vehicle Charging Station Upgraded with Flywheel Energy

  20. Challenges and Opportunities for Compound Semiconductor Devices in Next Generation Wireless Base Station Power Amplifiers

    E-Print Network [OSTI]

    Asbeck, Peter M.

    Station Power Amplifiers Lawrence Larson, Peter Asbeck, and Donald Kimball Center for Wireless Communications, Dept of ECE, UCSD, La Jolla, CA 92093 Abstract -- Power Amplifiers for cellular base stations their networks to 3G services in the coming years, it is expected that the market for base station power

  1. Cooperative Base Stations for Green Cellular Networks Choungmo Fofack Nicaise Eric

    E-Print Network [OSTI]

    the the base stations of an operator's network. 2.1 Power saving-oriented network and capacity planning model with no power saving. Methodology: the constraint (i) defines the minimum number of base stations to cover all represents a limitation on the power that can be saved by turning off some base stations completely

  2. Improving the Capacity in Wireless Networks Through Integrated Channel Base Station and Power Assignment

    E-Print Network [OSTI]

    Tassiulas, Leandros

    Improving the Capacity in Wireless Networks Through Integrated Channel Base Station and Power Allocation Algorithm (JRAA) that makes the channel base station and power assignment in a wireless net­ work base station and power assign­ ment. Finally several versions of the two­way channel assignment problem

  3. Observations of Earth space by self-powered stations in Antarctica S. B. Mende,1

    E-Print Network [OSTI]

    Mende, Stephen B.

    Observations of Earth space by self-powered stations in Antarctica S. B. Mende,1 W. Rachelson,1 R is the generation of power and heat for a sizable ground station that can accommodate an optical imaging instrument-coil magnetometers, and ELF/VLF and LM/MF/HF receivers. Originally these stations were powered by propane fuelled

  4. Joint Optimal Channel Base Station and Power Assignment for Wireless Access \\Lambda

    E-Print Network [OSTI]

    Tassiulas, Leandros

    Joint Optimal Channel Base Station and Power Assignment for Wireless Access \\Lambda Symeon powers, forward (downstream) and reverse (upstream) channels, and base stations such that every mobile the transmission powers both of the base stations and the users will be controllable. This great flexibility

  5. This memorandurn defines the manner in which central station heaters, power dumps and experilnent standby

    E-Print Network [OSTI]

    Rathbun, Julie A.

    This memorandurn defines the manner in which central station heaters, power dumps and experilnent power in the central station by an equally powerful heater during non-operating periods. It is s!VIS!ON ANN. PdUH:::~,ti\\JCH,. t~OATM- 453 lrltiV~MO. Gentral'Station Power and t

  6. AMS - a magnetic spectrometer on the international space station

    E-Print Network [OSTI]

    Arruda, Luísa; Barão, Fernando; Barreira, Gaspar; Borges, João; Gonçalves, Patrícia; Pimenta, Mário

    2008-01-01

    The Alpha Magnetic Spectrometer (AMS) is a particle detector, designed to search for cosmic antimatter and dark matter and to study the elemental and isotopic composition of primary cosmic rays, that will be installed on the International Space Station (ISS) in 2008 to operate for at least three years. The detector will be equipped with a ring imaging Cherenkov detector (RICH) enabling measurements of particle electric charge and velocity with unprecedented accuracy. Physics prospects and test beam results are shortly presented.

  7. AMS - a magnetic spectrometer on the international space station

    E-Print Network [OSTI]

    Luísa Arruda; Rui Pereira; Fernando Barão; Gaspar Barreira; João Borges; Patrícia Gonçalves; Mário Pimenta

    2008-01-31

    The Alpha Magnetic Spectrometer (AMS) is a particle detector, designed to search for cosmic antimatter and dark matter and to study the elemental and isotopic composition of primary cosmic rays, that will be installed on the International Space Station (ISS) in 2008 to operate for at least three years. The detector will be equipped with a ring imaging Cherenkov detector (RICH) enabling measurements of particle electric charge and velocity with unprecedented accuracy. Physics prospects and test beam results are shortly presented.

  8. Lowry Range Solar Station: Arapahoe County, Colorado (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Yoder, M.; Andreas, A.

    A partnership with industry and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

  9. Nevada Power: Clark Station; Las Vegas, Nevada (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Stoffel, T.; Andreas, A.

    A partnership with the University of Nevada and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

  10. Lowry Range Solar Station: Arapahoe County, Colorado (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Yoder, M.; Andreas, A.

    2008-05-30

    A partnership with industry and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

  11. Nevada Power: Clark Station; Las Vegas, Nevada (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Stoffel, T.; Andreas, A.

    2006-03-27

    A partnership with the University of Nevada and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

  12. Tampa Electric Company Polk Power Station IGCC project: Project status

    SciTech Connect (OSTI)

    McDaniel, J.E.; Carlson, M.R.; Hurd, R.; Pless, D.E.; Grant, M.D.

    1997-12-31

    The Tampa Electric Company Polk Power Station is a nominal 250 MW (net) Integrated Gasification Combined Cycle (IGCC) power plant located to the southeast of Tampa, Florida in Polk County, Florida. This project is being partially funded under the Department of Energy`s Clean Coal Technology Program pursuant to a Round II award. The Polk Power Station uses oxygen-blown, entrained-flow IGCC technology licensed from Texaco Development Corporation to demonstrate significant reductions of SO{sub 2} and NO{sub x} emissions when compared to existing and future conventional coal-fired power plants. In addition, this project demonstrates the technical feasibility of commercial scale IGCC and Hot Gas Clean Up (HGCU) technology. The Polk Power Station achieved ``first fire`` of the gasification system on schedule in mid-July, 1996. Since that time, significant advances have occurred in the operation of the entire IGCC train. This paper addresses the operating experiences which occurred in the start-up and shakedown phase of the plant. Also, with the plant being declared in commercial operation as of September 30, 1996, the paper discusses the challenges encountered in the early phases of commercial operation. Finally, the future plans for improving the reliability and efficiency of the Unit in the first quarter of 1997 and beyond, as well as plans for future alternate fuel test burns, are detailed. The presentation features an up-to-the-minute update on actual performance parameters achieved by the Polk Power Station. These parameters include overall Unit capacity, heat rate, and availability. In addition, the current status of the start-up activities for the HGCU portion of the plant is discussed.

  13. Alternative Fuels Data Center: About the Alternative Fueling Station Data

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home Page on Digg FindPorts USAEthanolStateLocate Stations Printable

  14. Alternative Fuels Data Center: Ethanol Fueling Station Locations

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home PageBlender Pump Dispensers toStation Locations to someone by

  15. Alternative Fuels Data Center: Hydrogen Fueling Station Locations

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home PageBlender Pump Dispensers toStationNaturalSchoolsHydrogen

  16. Alternative Fuels Data Center: Natural Gas Fueling Station Locations

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home PageBlender Pump DispensersEmergingMinneapolisStation Locations

  17. Locating PHEV exchange stations in V2G

    SciTech Connect (OSTI)

    Pan, Feng; Bent, Russell; Berscheid, Alan; Izraelevitz, David

    2010-01-01

    Plug-in hybrid electric vehicle (PREV) is an environment friendly modem transportation method and has been rapidly penetrate the transportation system. Renewable energy is another contributor to clean power but the associated intermittence increases the uncertainty in power generation. As a foreseen benefit of a vchicle-to-grid (V2G) system, PREV supporting infrastructures like battery exchange stations can provide battery service to PREV customers as well as being plugged into a power grid as energy sources and stabilizer. The locations of exchange stations are important for these two objectives under constraints from both ,transportation system and power grid. To model this location problem and to understand and analyze the benefit of a V2G system, we develop a two-stage stochastic program to optimally locate the stations prior to the realizations of battery demands, loads, and generation capacity of renewable power sources. Based on this model, we use two data sets to construct the V2G systems and test the benefit and the performance of these systems.

  18. IQ-Station: A Low Cost Portable Immersive Environment

    SciTech Connect (OSTI)

    Eric Whiting; Patrick O'Leary; William Sherman; Eric Wernert

    2010-11-01

    The emergence of inexpensive 3D TV’s, affordable input and rendering hardware and open-source software has created a yeasty atmosphere for the development of low-cost immersive environments (IE). A low cost IE system, or IQ-station, fashioned from commercial off the shelf technology (COTS), coupled with a targeted immersive application can be a viable laboratory instrument for enhancing scientific workflow for exploration and analysis. The use of an IQ-station in a laboratory setting also has the potential of quickening the adoption of a more sophisticated immersive environment as a critical enabler in modern scientific and engineering workflows. Prior work in immersive environments generally required either a head mounted display (HMD) system or a large projector-based implementation both of which have limitations in terms of cost, usability, or space requirements. The solution presented here provides an alternative platform providing a reasonable immersive experience that addresses those limitations. Our work brings together the needed hardware and software to create a fully integrated immersive display and interface system that can be readily deployed in laboratories and common workspaces. By doing so, it is now feasible for immersive technologies to be included in researchers’ day-to-day workflows. The IQ-Station sets the stage for much wider adoption of immersive environments outside the small communities of virtual reality centers.

  19. The ALTCRISS project on board the International Space Station

    E-Print Network [OSTI]

    M. Casolino; F. Altamura; M. Minori; P. Picozza; C. Fuglesang; A. Galper; A. Popov; V. Benghin; V. M. Petrov; A. Nagamatsu; T. Berger; G. Reitz; M. Durante; M. Pugliese; V. Roca; L. Sihver F. Cucinotta; E. Semones; M. Shavers; V. Guarnieri; C. Lobascio; D. Castagnolo; R. Fortezza

    2007-08-20

    The Altcriss project aims to perform a long term survey of the radiation environment on board the International Space Station. Measurements are being performed with active and passive devices in different locations and orientations of the Russian segment of the station. The goal is to perform a detailed evaluation of the differences in particle fluence and nuclear composition due to different shielding material and attitude of the station. The Sileye-3/Alteino detector is used to identify nuclei up to Iron in the energy range above 60 MeV/n. Several passive dosimeters (TLDs, CR39) are also placed in the same location of Sileye-3 detector. Polyethylene shielding is periodically interposed in front of the detectors to evaluate the effectiveness of shielding on the nuclear component of the cosmic radiation. The project was submitted to ESA in reply to the AO in the Life and Physical Science of 2004 and data taking began in December 2005. Dosimeters and data cards are rotated every six months: up to now three launches of dosimeters and data cards have been performed and have been returned with the end of expedition 12 and 13.

  20. The ALTCRISS project on board the International Space Station

    E-Print Network [OSTI]

    Casolino, M; Minori, M; Picozza, P; Fuglesang, C; Galper, A; Popov, A; Benghin, V; Petrov, V M; Nagamatsu, A; Berger, T; Reitz, G; Durante, M; Pugliese, M; Roca, V; Cucinotta, L Sihver F; Semones, E; Shavers, M; Guarnieri, V; Lobascio, C; Castagnolo, D; Fortezza, R

    2007-01-01

    The Altcriss project aims to perform a long term survey of the radiation environment on board the International Space Station. Measurements are being performed with active and passive devices in different locations and orientations of the Russian segment of the station. The goal is to perform a detailed evaluation of the differences in particle fluence and nuclear composition due to different shielding material and attitude of the station. The Sileye-3/Alteino detector is used to identify nuclei up to Iron in the energy range above 60 MeV/n. Several passive dosimeters (TLDs, CR39) are also placed in the same location of Sileye-3 detector. Polyethylene shielding is periodically interposed in front of the detectors to evaluate the effectiveness of shielding on the nuclear component of the cosmic radiation. The project was submitted to ESA in reply to the AO in the Life and Physical Science of 2004 and data taking began in December 2005. Dosimeters and data cards are rotated every six months: up to now three lau...

  1. Analysis of clear hour solar irradiation for seven Canadian stations

    SciTech Connect (OSTI)

    Garrison, J.; Sahami, K.

    1995-12-31

    Hourly global and diffuse irradiation and corresponding surface meteorological data have been analyzed for the seven Canadian stations at Edmonton, Goose Bay, Montreal, Port Hardy, Resolute, Toronto, and Winnipeg. The variation of the most probable clear hour values of clearness index k{sub t}, diffuse index k{sub d}, direct beam index k{sub b}, and Angstrom turbidity coefficient {beta} with solar elevation, atmospheric precipitable water, and snow depth are obtained. Values of these quantities are presented which are consistent with the attenuation and scattering of solar radiation by the atmosphere which is expected. The most probable values of {beta} tend to be lower than the average values of {beta} recently reported by Gueymard. The data indicate a drift in the calibration of the instruments used for measurements of the irradiation data for the stations at Goose Bay and Resolute. The data for the other five stations indicate that the instrument calibration is maintained over the years of the data. 4 refs., 8 figs., 5 tabs.

  2. Geothermal energy at Long Beach Naval Shipyard and Naval Station and at Seal Beach Naval Weapons Station, California. Final report

    SciTech Connect (OSTI)

    Higgins, C.T.; Chapman, R.H.

    1984-01-01

    The purpose of this project was to determine and evaluate sources of geothermal energy at two military bases in southern California, the Long Beach Naval Shipyard and Naval Station and the Seal Beach Naval Weapons Station. One part of the project focused on the natural geothermal characteristics beneath the naval bases. Another part focused on the geothermal energy produced by oilfield operations on and adjacent to each base. Results of the study are presented here for the US Department of the Navy to use in its program to reduce its reliance on petrolem by the development of different sources of energy. The study was accomplished under a cooperative agreement between the US Department of Energy's San Francisco Operations Office and the Department of the Navy's Naval Weapons Center, China Lake, California, for joint research and development of geothermal energy at military installations.

  3. Single rotor turbine engine

    DOE Patents [OSTI]

    Platts, David A. (Los Alamos, NM)

    2002-01-01

    There has been invented a turbine engine with a single rotor which cools the engine, functions as a radial compressor, pushes air through the engine to the ignition point, and acts as an axial turbine for powering the compressor. The invention engine is designed to use a simple scheme of conventional passage shapes to provide both a radial and axial flow pattern through the single rotor, thereby allowing the radial intake air flow to cool the turbine blades and turbine exhaust gases in an axial flow to be used for energy transfer. In an alternative embodiment, an electric generator is incorporated in the engine to specifically adapt the invention for power generation. Magnets are embedded in the exhaust face of the single rotor proximate to a ring of stationary magnetic cores with windings to provide for the generation of electricity. In this alternative embodiment, the turbine is a radial inflow turbine rather than an axial turbine as used in the first embodiment. Radial inflow passages of conventional design are interleaved with radial compressor passages to allow the intake air to cool the turbine blades.

  4. NGV stations based on mobile tube trailers: An economic analysis. Final report, June 1994-January 1995

    SciTech Connect (OSTI)

    Keder, J.; Darrow, K.

    1995-01-01

    This report assesses the technical and economic issues associated with the use of mobile tube trailers for Natural Gas Vehicle (NGV) refueling stations. Specifically, this report examines the mobile tube trailer concept developed by Pacific Cryongenics, Inc. and Pacific Gas and Electric. Mobile tube trailers are filled with compressed natural gas (CNG) at an underutilized compressor station and transported to satellite station locations. NGVs are filled at the satellite stations usig compressed gas from the tube trailer. Results of the economic analysis show that, under various operating conditions, the mobile tube trailer concept provides a cost effective alternative to NGV refueling stations with permanent compressors. In addition, the tube trailers were found to provide a substantial load for undertutilized compressor stations, resulting in reduced CNG costs at existing stations.

  5. Comment on "Single Crystals of Single-Walled Carbon Nanotubes

    E-Print Network [OSTI]

    Natelson, Douglas

    Comment on "Single Crystals of Single-Walled Carbon Nanotubes Formed by Self-Assembly" Schlittler) by the thermolysis of nano- patterned structures of alternating layers of C60 and nickel. Electron diffraction, high

  6. First Report of Nectria galligena Causing European Canker of Apple Trees in Ontario. A. R. Biggs, Agriculture Canada Research Station, Vineland Station, Ontario LOR 2EO. Plant

    E-Print Network [OSTI]

    Biggs, Alan R.

    First Report of Nectria galligena Causing European Canker of Apple Trees in Ontario. A. R. Biggs, Agriculture Canada Research Station, Vineland Station, Ontario LOR 2EO. Plant Disease 69:1007, 1985. Accepted galligena Bres. was first observed in Wentworth County, Ontario, Canada, in March 1985. The fungus had been

  7. Vehicles and E85 Stations Needed to Achieve Ethanol Goals

    SciTech Connect (OSTI)

    Greene, David L [ORNL

    2008-01-01

    This paper presents an analysis of the numbers of stations and vehicles necessary to achieve future goals for sales of ethanol fuel (E85). The paper does not analyze issues related to the supply of ethanol which may turn out to be of even greater concern. A model of consumers decisions to purchase E85 versus gasoline based on prices, availability, and refueling frequency is derived and preliminary results for 2010, 2017 and 2030 consistent with the President s 2007 biofuels program goals are presented (1). A limited sensitivity analysis is carried out to indicate key uncertainties in the trade-off between the number of stations and fuels. The analysis indicates that to meet a 2017 goal of 26 billion gallons of E85 sold, on the order of 30% to 80% of all stations may need to offer E85, and that 125 to 200 million flexible fuel vehicles (FFVs) may need to be on the road, even if oil prices remain high. These conclusions are tentative for three reasons: (1) there is considerable uncertainty about key parameter values, such as the price elasticity of choice between E85 and gasoline, (2) the future prices of E85 and gasoline are uncertain; and (3) the method of analysis used is highly aggregated; it does not consider the potential benefits of regional strategies nor the possible existence of market segments predisposed to purchase E85. Nonetheless, the preliminary results indicate that the 2017 biofuels program goals are ambitious and will require a massive effort to produce FFVs and insure widespread availability of E85.

  8. Analysis of allowed outage times at the Byron Generating Station

    SciTech Connect (OSTI)

    Cho, N.Z.; Chu, T.L.; Xue, D.; Bozoki, G.E.; Youngblood, R.W.

    1986-06-01

    This report provides a critical review of the methods used in WCAP-10526 which proposed that allowed outage times (AOTs) for a number of safety systems in the Byron Generating Station be increased from 3 to 7 days, and presents an independent estimate of the change in risk involved in the AOT extension. It also presents results of several sensitivity studies. Also included are a survey of methods that can be used to evaluate nuclear power plant technical specifications and a description of pairwise importance measures. 53 tabs.

  9. Hydrogen Fueling Station in Honolulu, Hawaii Feasibility Analysis

    SciTech Connect (OSTI)

    Porter Hill; Michael Penev

    2014-08-01

    The Department of Energy Hydrogen & Fuel Cells Program Plan (September 2011) identifies the use of hydrogen for government and fleet electric vehicles as a key step for achieving “reduced greenhouse gas emissions; reduced oil consumption; expanded use of renewable power …; highly efficient energy conversion; fuel flexibility …; reduced air pollution; and highly reliable grid-support.” This report synthesizes several pieces of existing information that can inform a decision regarding the viability of deploying a hydrogen (H2) fueling station at the Fort Armstrong site in Honolulu, Hawaii.

  10. Insights from Hydrogen Refueling Station Manufacturing Competitiveness Analysis

    SciTech Connect (OSTI)

    Mayyas, Ahmad

    2015-12-18

    In work for the Clean Energy Manufacturing Analysis Center (CEMAC), NREL is currently collaborating with Great Lakes Wind Network in conducting a comprehensive hydrogen refueling stations manufacturing competitiveness and supply chain analyses. In this project, CEMAC will be looking at several metrics that will facilitate understanding of the interactions between and within the HRS supply chain, such metrics include innovation potential, intellectual properties, learning curves, related industries and clustering, existing supply chains, ease of doing business, and regulations and safety. This presentation to Fuel Cell Seminar and Energy Exposition 2015 highlights initial findings from CEMAC's analysis.

  11. No loss fueling station for liquid natural gas vehicles

    SciTech Connect (OSTI)

    Cieslukowski, R.E.

    1992-06-16

    This patent describes a no loss fueling station for delivery of liquid natural gas (LNG) to a use device such as a motor vehicle. It comprises: a pressure building tank holding a quantity of LNG and gas head; means for delivering LNG to the pressure building tank; means for selectively building the pressure in the pressure building tank; means for selectively reducing the pressure in the pressure building tank; means for controlling the pressure building and pressure reducing means to maintain a desired pressure in the pressure building tank without venting natural gas to the atmosphere; and means for delivering the LNG from the pressure building tank to the use device.

  12. The Alpha Magnetic Spectrometer on the International Space Station

    E-Print Network [OSTI]

    Carmen Palomares

    2005-05-20

    The Alpha Magnetic Spectrometer (AMS) is a particle physics detector designed to operate on the International Space Station (ISS). The aim of AMS is the direct detection of charged particles in the rigidity range from 0.5 GV to few TV to perform high statistics studies of cosmic rays in space and search for antimatter and dark matter. This will be possible because of the large geometrical acceptance, a very accurate energy determination and a very precise particle identification through redundant measurements of its energy, velocity and electric charge. AMS is scheduled to be placed on the ISS at the beginning of 2008 for a 3 year exposure.

  13. Huntington Station, New York: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History View NewTexas: Energy Resources JumpNewTexas: EnergyHunterdon County, NewHuntingStation, New York:

  14. Ottawa Generating Station Biomass Facility | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio Program | OpenWisconsin:New York:Policy JumpGenerating Station

  15. List of Refueling Stations Incentives | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIXsource History ViewInformationWindsCompressedList of Refueling Stations Incentives

  16. Archbald Power Station Biomass Facility | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop IncIowaWisconsin: EnergyYork Jump| OpenExploration AtArchbald Power Station

  17. Measuring single-cell density

    E-Print Network [OSTI]

    Grover, William H.

    We have used a microfluidic mass sensor to measure the density of single living cells. By weighing each cell in two fluids of different densities, our technique measures the single-cell mass, volume, and density of ...

  18. Hybrid Enrichment Assay Methods for a UF6 Cylinder Verification Station: FY10 Progress Report

    SciTech Connect (OSTI)

    Smith, Leon E.; Jordan, David V.; Orton, Christopher R.; Misner, Alex C.; Mace, Emily K.

    2010-08-01

    Pacific Northwest National Laboratory (PNNL) is developing the concept of an automated UF6 cylinder verification station that would be located at key measurement points to positively identify each cylinder, measure its mass and enrichment, store the collected data in a secure database, and maintain continuity of knowledge on measured cylinders until the arrival of International Atomic Energy Agency (IAEA) inspectors. At the center of this unattended system is a hybrid enrichment assay technique that combines the traditional enrichment-meter method (based on the 186 keV peak from 235U) with non-traditional neutron-induced high-energy gamma-ray signatures (spawned primarily by 234U alpha emissions and 19F(alpha, neutron) reactions). Previous work by PNNL provided proof-of-principle for the non-traditional signatures to support accurate, full-volume interrogation of the cylinder enrichment, thereby reducing the systematic uncertainties in enrichment assay due to UF6 heterogeneity and providing greater sensitivity to material substitution scenarios. The work described here builds on that preliminary evaluation of the non-traditional signatures, but focuses on a prototype field system utilizing NaI(Tl) and LaBr3(Ce) spectrometers, and enrichment analysis algorithms that integrate the traditional and non-traditional signatures. Results for the assay of Type-30B cylinders ranging from 0.2 to 4.95 wt% 235U, at an AREVA fuel fabrication plant in Richland, WA, are described for the following enrichment analysis methods: 1) traditional enrichment meter signature (186 keV peak) as calculated using a square-wave convolute (SWC) algorithm; 2) non-traditional high-energy gamma-ray signature that provides neutron detection without neutron detectors and 3) hybrid algorithm that merges the traditional and non-traditional signatures. Uncertainties for each method, relative to the declared enrichment for each cylinder, are calculated and compared to the uncertainties from an attended HPGe verification station at AREVA, and the IAEA’s uncertainty target values for feed, tail and product cylinders. A summary of the major findings from the field measurements and subsequent analysis follows: • Traditional enrichment-meter assay using specially collimated NaI spectrometers and a Square-Wave-Convolute algorithm can achieve uncertainties comparable to HPGe and LaBr for product, natural and depleted cylinders. • Non-traditional signatures measured using NaI spectrometers enable interrogation of the entire cylinder volume and accurate measurement of absolute 235U mass in product, natural and depleted cylinders. • A hybrid enrichment assay method can achieve lower uncertainties than either the traditional or non-traditional methods acting independently because there is a low degree of correlation in the systematic errors of the two individual methods (wall thickness variation and 234U/235U variation, respectively). This work has indicated that the hybrid NDA method has the potential to serve as the foundation for an unattended cylinder verification station. When compared to today’s handheld cylinder-verification approach, such a station would have the following advantages: 1) improved enrichment assay accuracy for product, tail and feed cylinders; 2) full-volume assay of absolute 235U mass; 3) assay of minor isotopes (234U and 232U) important to verification of feedstock origin; single instrumentation design for both Type 30B and Type 48 cylinders; and 4) substantial reduction in the inspector manpower associated with cylinder verification.

  19. Title: Dormant Smokestacks and Silent Turbines: The Adaptive Reuse of Early to Mid-twentieth century Power Stations

    E-Print Network [OSTI]

    -twentieth century Power Stations Author: Aliza Ross Advisor: Carol Clark The early to mid-century central station, identified today as a power station or power plant, has intrigued communities, architectural historians industrial buildings. Sited in historic industrial zones once discrete from city?s downtowns, power stations

  20. Experimental Single-Photon Transmission from Satellite to Earth

    E-Print Network [OSTI]

    Juan Yin; Yuan Cao; Shu-Bin Liu; Ge-Sheng Pan; Jin-Hong Wang; Tao Yang; Zhong-Ping Zhang; Fu-Min Yang; Yu-Ao Chen; Cheng-Zhi Peng; Jian-Wei Pan

    2013-06-04

    Free-space quantum communication with satellites opens a promising avenue for global secure quantum network and large-scale test of quantum foundations. Recently, numerous experimental efforts have been carried out towards this ambitious goal. However, one essential step - transmitting single photons from the satellite to the ground with high signal-to-noise ratio (SNR) at realistic environments - remains experimental challenging. Here, we report a direct experimental demonstration of the satellite-ground transmission of a quasi-single-photon source. In the experiment, single photons (~0.85 photon per pulse) are generated by reflecting weak laser pulses back to earth with a cube-corner retro-reflector on the satellite Champ, collected by a 600-mm diameter telescope at the ground station, and finally detected by single-photon counting modules (SPCMs) after 400-km free-space link transmission. With the help of high accuracy time synchronization, narrow receiver field-of-view (FOV) and high-repetition-rate pulses (76 MHz), a SNR of better than 16:1 is obtained, which is sufficient for a secure quantum key distribution. Our experimental results represent an important step towards satellite-ground quantum communication.

  1. Sibley station low-sulfur coal conversion program

    SciTech Connect (OSTI)

    Rupinskas, R.L. [Sargent & Lundy LLC, Chicago, IL (United States); Rembold, D.F. [Missouri Public Service, Kansas City, MO (United States)

    1995-03-01

    After embarking on an upgrade project in 1986 that was designed to allow efficient and reliable operation of its coal-fired Sibley station through 2010, Missouri Public Service (MPS) faced the uncertainty of impending acid-rain legislation. To protect its investment in the Sibley Rebuild Program, the utility evaluated compliance options based on the emerging legislation and concluded that switching to low-sulfur coal offered the least-cost compliance approach. Compared to installing a scrubber, switching to a low-sulfur coal was also more straightforward, although not without challenges and complications. This paper reviews the Sibley low-sulfur coal conversion program. At Sibley, fuel switching was chosen only after numerous internal and external studies; it withstood late challenges from natural gas and allowance trading. Switching demanded additional equipment to blend Power River Basin coals and other coals, and demanded additional and upgraded protective equipment in the areas of fire protection, dust collection, and explosion prevention. In the year since the coal conversion project was completed the facility has operated reliably, the economic benefits of the lower cost Powder River Basin coals have been realized, and the station has also met the requirements of both phases of the acid rain legislation. Fuel switching at Sibley required a team approach and careful analysis. The coal conversion project also required attention and dedication by team members in order to minimize fuel costs while maintaining optimum plant efficiency and availability.

  2. Fire Protection Engineering Design Brief Template. Hydrogen Refueling Station.

    SciTech Connect (OSTI)

    LaFleur, Angela Christine; Muna, Alice Baca; Groth, Katrina M.

    2015-08-01

    Building a hydrogen infrastructure system is critical to supporting the development of alternate- fuel vehicles. This report provides a methodology for implementing a performance-based design of an outdoor hydrogen refueling station that does not meet specific prescriptive requirements in NFPA 2, The Hydrogen Technologies Code . Performance-based designs are a code-compliant alternative to meeting prescriptive requirements. Compliance is demonstrated by comparing a prescriptive-based fueling station design with a performance-based design approach using Quantitative Risk Assessment (QRA) methods and hydrogen risk assessment tools. This template utilizes the Sandia-developed QRA tool, Hydrogen Risk Analysis Models (HyRAM), which combines reduced-order deterministic models that characterize hydrogen release and flame behavior with probabilistic risk models to quantify risk values. Each project is unique and this template is not intended to account for site-specific characteristics. Instead, example content and a methodology are provided for a representative hydrogen refueling site which can be built upon for new hydrogen applications.

  3. Tampa Electric Company`s Polk Power Station IGCC project

    SciTech Connect (OSTI)

    Jenkins, S.D.

    1995-12-31

    Tampa Electric Company (TEC) is in the construction phase of its new Polk Power Station Unit No. 1. This unique project incorporates the use of Integrated Gasification Combined Cycle (IGCC) technology for electric power production. The project is being partially funded by the US Department of Energy (DOE), as part of the Clean Coal Technology Program. This will help to demonstrate this state-of-the-art technology, providing utilities with the ability to use a wide range of coals in an efficient, environmentally superior manner. During the summer of 1994, TEC began site development at the new Polk Power Station. Since that time, most of the Site work has been completed, and erection and installation of the power plant equipment is well underway. This is the first time that IGCC technology will be installed at a new unit at a greenfield site. This is a major endeavor for TEC in that Polk Unit No. 1 is a major addition to the existing generating capacity and it involves the demonstration of technology new to utility power generation. As a part of the Cooperative Agreement with the DOE, TEC will also be demonstrating the use of a new Hot Gas Clean-Up System which has a potential for greater IGCC efficiency.

  4. Thermohydraulic and Safety Analysis for CARR Under Station Blackout Accident

    SciTech Connect (OSTI)

    Wenxi Tian; Suizheng Qiu; Guanghui Su; Dounan Jia [Xi'an Jiaotong University, 28 Xianning Road, Xi'an 710049 (China); Xingmin Liu - China Institute of Atomic Energy

    2006-07-01

    A thermohydraulic and safety analysis code (TSACC) has been developed using Fortran 90 language to evaluate the transient thermohydraulic behaviors and safety characteristics of the China Advanced Research Reactor(CARR) under Station Blackout Accident(SBA). For the development of TSACC, a series of corresponding mathematical and physical models were considered. Point reactor neutron kinetics model was adopted for solving reactor power. All possible flow and heat transfer conditions under station blackout accident were considered and the optional models were supplied. The usual Finite Difference Method (FDM) was abandoned and a new model was adopted to evaluate the temperature field of core plate type fuel element. A new simple and convenient equation was proposed for the resolution of the transient behaviors of the main pump instead of the complicated four-quadrant model. Gear method and Adams method were adopted alternately for a better solution to the stiff differential equations describing the dynamic behaviors of the CARR. The computational result of TSACC showed the enough safety margin of CARR under SBA. For the purpose of Verification and Validation (V and V), the simulated results of TSACC were compared with those of Relap5/Mdo3. The V and V result indicated a good agreement between the results by the two codes. Because of the adoption of modular programming techniques, this analysis code is expected to be applied to other reactors by easily modifying the corresponding function modules. (authors)

  5. Adjusting flow station job to remote Nigerian location yields savings

    SciTech Connect (OSTI)

    Wooten, R.; Williams, E.C. (OPI International Inc., Houston, TX (United States))

    1994-05-02

    In September 1991, Chevron Nigeria Ltd. and Nigerian National Petroleum Crop. contracted Offshore Pipelines to design, procure, construct, install, and commission the Opuekeba 30,000 b/d crude-oil flow station on an offshore platform near Olero Creek, Nigeria, approximately 22 miles from the nearest deepwater access. Chevron's original project plan included bringing the flow station to the site in small packages and then assembling it in a lengthy field hook-up process. Offshore Pipelines developed a plan early in the project to maximize construction and hook-up in the fabrication yard, then transport the nearly complete structures to site by way of a newly dredged canal. What proved to be most difficult was the site location in Nigeria. Job planning and communication were important in the successful completion of the project. Keeping the components of the large and complex facility simple proved to be effective and efficient and played a key role in completing the project on time and within budget. The paper discusses overcoming obstacles, lift and depth constraints, dredging, fabrication, installation, and large-time problems.

  6. A prototype station for ARIANNA: a detector for cosmic neutrinos

    SciTech Connect (OSTI)

    Gerhardt, L.; Klein, S.; Stezelberger, T.; Barwick, S.; Dookayka, K.; Hanson, J.; Nichol, R.

    2010-05-27

    The Antarctic Ross Iceshelf Antenna Neutrino Array (ARIANNA) is a proposed detector for ultra-high energy astrophysical neutrinos. It will detect coherent radio Cherenkov emission from the particle showers produced by neutrinos with energies above about 1017 eV. ARIANNA will be built on the Ross Ice Shelf just off the coast of Antarctica, where it will eventually cover about 900 km2 in surface area. There, the ice-water interface below the shelf reflects radio waves, giving ARIANNA sensitivity to downward going neutrinos and improving its sensitivity to horizontally incident neutrinos. ARIANNA detector stations will each contain 4-8 antennas which search for brief pulses of 50 MHz to 1 GHz radio emission from neutrino interactions. We describe a prototype station for ARIANNA which was deployed in Moore's Bay on the Ross Ice Shelf in December 2009, discuss the design and deployment, and present some initial figures on performance. The ice shelf thickness was measured to be 572 +- 6 m at the deployment site.

  7. Indistinguishability of independent single photons

    E-Print Network [OSTI]

    F. W. Sun; C. W. Wong

    2009-02-02

    The indistinguishability of independent single photons is presented by decomposing the single photon pulse into the mixed state of different transform limited pulses. The entanglement between single photons and outer environment or other photons induces the distribution of the center frequencies of those transform limited pulses and makes photons distinguishable. Only the single photons with the same transform limited form are indistinguishable. In details, the indistinguishability of single photons from the solid-state quantum emitter and spontaneous parametric down conversion is examined with two-photon Hong-Ou-Mandel interferometer. Moreover, experimental methods to enhance the indistinguishability are discussed, where the usage of spectral filter is highlighted.

  8. Regulations, Codes, and Standards (RCS) Template for California Hydrogen Dispensing Stations

    SciTech Connect (OSTI)

    Rivkin, C.; Blake, C.; Burgess, R.; Buttner, W.; Post, M.

    2012-11-01

    This report explains the Regulations, Codes, and Standards (RCS) requirements for hydrogen dispensing stations in the State of California. The reports shows the basic components of a hydrogen dispensing station in a simple schematic drawing; the permits and approvals that would typically be required for the construction and operation of a hydrogen dispensing station; and a basic permit that might be employed by an Authority Having Jurisdiction (AHJ).

  9. Electron and Positron Fluxes in Primary Cosmic Rays Measured with the Alpha Magnetic Spectrometer on the International Space Station

    E-Print Network [OSTI]

    Aguilar, M; Alvino, A; Ambrosi, G; Andeen, K; Arruda, L; Attig, N; Azzarello, P; Bachlechner, A; Barao, F; Barrau, A; Barrin, L; Bartoloni, A; Basara, L; Battarbee, M; Battiston, R; Bazo, J; Becker, U; Behlmann, M; Beischer, B; Berdugo, J; Bertucci, B; Bigongiari, G; Bindi, V; Bizzaglia, S; Bizzarri, M; Boella, G; de Boer, W; Bollweg, K; Bonnivard, V; Borgia, B; Borsini, S; Boschini, M J; Bourquin, M; Burger, J; Cadoux, F; Cai, X D; Capell, M; Caroff, S; Casaus, J; Cascioli, V; Castellini, G; Cernuda, I; Cervelli, F; Chae, M J; Chang, Y H; Chen, A I; Chen, H; Cheng, G M; Chen, H S; Cheng, L; Chikanian, A; Chou, H Y; Choumilov, E; Choutko, V; Chung, C H; Clark, C; Clavero, R; Coignet, G; Consolandi, C; Contin, A; Corti, C; Coste, B; Cui, Z; Dai, M; Delgado, C; Della Torre, S; Demirköz, M B; Derome, L; Di Falco, S; Di Masso, L; Dimiccoli, F; Díaz, C; von Doetinchem, P; Du, W J; Duranti, M; D’Urso, D; Eline, A; Eppling, F J; Eronen, T; Fan, Y Y; Farnesini, L; Feng, J; Fiandrini, E; Fiasson, A; Finch, E; Fisher, P; Galaktionov, Y; Gallucci, G; García, B; García-López, R; Gast, H; Gebauer, I; Gervasi, M; Ghelfi, A; Gillard, W; Giovacchini, F; Goglov, P; Gong, J; Goy, C; Grabski, V; Grandi, D; Graziani, M; Guandalini, C; Guerri, I; Guo, K H; Habiby, M; Haino, S; Han, K C; He, Z H; Heil, M; Hoffman, J; Hsieh, T H; Huang, Z C; Huh, C; Incagli, M; Ionica, M; Jang, W Y; Jinchi, H; Kanishev, K; Kim, G N; Kim, K S; Kirn, Th; Kossakowski, R; Kounina, O; Kounine, A; Koutsenko, V; Krafczyk, M S; Kunz, S; La Vacca, G; Laudi, E; Laurenti, G; Lazzizzera, I; Lebedev, A; Lee, H T; Lee, S C; Leluc, C; Li, H L; Li, J Q; Li, Q; Li, Q; Li, T X; Li, W; Li, Y; Li, Z H; Li, Z Y; Lim, S; Lin, C H; Lipari, P; Lippert, T; Liu, D; Liu, H; Lomtadze, T; Lu, M J; Lu, Y S; Luebelsmeyer, K; Luo, F; Luo, J Z; Lv, S S; Majka, R; Malinin, A; Mañá, C; Marín, J; Martin, T; Martínez, G; Masi, N; Maurin, D; Menchaca-Rocha, A; Meng, Q; Mo, D C; Morescalchi, L; Mott, P; Müller, M; Ni, J Q; Nikonov, N; Nozzoli, F; Nunes, P; Obermeier, A; Oliva, A; Orcinha, M; Palmonari, F; Palomares, C; Paniccia, M; Papi, A; Pedreschi, E; Pensotti, S; Pereira, R; Pilo, F; Piluso, A; Pizzolotto, C; Plyaskin, V; Pohl, M; Poireau, V; Postaci, E; Putze, A; Quadrani, L; Qi, X M; Rancoita, P G; Rapin, D; Ricol, J S; Rodríguez, I; Rosier-Lees, S; Rozhkov, A; Rozza, D; Sagdeev, R; Sandweiss, J; Saouter, P; Sbarra, C; Schael, S; Schmidt, S M; Schuckardt, D; Schulz von Dratzig, A; Schwering, G; Scolieri, G; Seo, E S; Shan, B S; Shan, Y H; Shi, J Y; Shi, X Y; Shi, Y M; Siedenburg, T; Son, D; Spada, F; Spinella, F; Sun, W; Sun, W H; Tacconi, M; Tang, C P; Tang, X W; Tang, Z C; Tao, L; Tescaro, D; Ting, Samuel C C; Ting, S M; Tomassetti, N; Torsti, J; Türko?lu, C; Urban, T; Vagelli, V; Valente, E; Vannini, C; Valtonen, E; Vaurynovich, S; Vecchi, M; Velasco, M; Vialle, J P; Wang, L Q; Wang, Q L; Wang, R S; Wang, X; Wang, Z X; Weng, Z L; Whitman, K; Wienkenhöver, J; Wu, H; Xia, X; Xie, M; Xie, S; Xiong, R Q; Xin, G M; Xu, N S; Xu, W; Yan, Q; Yang, J; Yang, M; Ye, Q H; Yi, H; Yu, Y J; Yu, Z Q; Zeissler, S; Zhang, J H; Zhang, M T; Zhang, X B; Zhang, Z; Zheng, Z M; Zhuang, H L; Zhukov, V; Zichichi, A; Zimmermann, N; Zuccon, P; Zurbach, C

    2014-01-01

    Precision measurements by the Alpha Magnetic Spectrometer on the International Space Station of the primary cosmic-ray electron flux in the range 0.5 to 700 GeV and the positron flux in the range 0.5 to 500 GeV are presented. The electron flux and the positron flux each require a description beyond a single power-law spectrum. Both the electron flux and the positron flux change their behavior at ?30??GeV but the fluxes are significantly different in their magnitude and energy dependence. Between 20 and 200 GeV the positron spectral index is significantly harder than the electron spectral index. The determination of the differing behavior of the spectral indices versus energy is a new observation and provides important information on the origins of cosmic-ray electrons and positrons.

  10. Hydrogen Energy Stations: Poly-Production of Electricity, Hydrogen, and Thermal Energy

    E-Print Network [OSTI]

    Lipman, Timothy; Brooks, Cameron

    2006-01-01

    is fuel cells for stationary applications (Connecticut Cleanof stationary fuel cells in energy station applications inenergy applications of hydrogen and fuel cell technologies.

  11. Next Generation Hydrogen Station Composite Data Products: Data through Quarter 2 of 2013

    SciTech Connect (OSTI)

    Sprik, S.; Kurtz, J.; Ainscough, C.; Post, M.; Saur, G.; Peters, M.

    2013-11-01

    This report includes 18 composite data products (CDPs) produced for next generation hydrogen stations, with data through quarter 2 of 2013.

  12. Hydrogen Energy Stations: Poly-Production of Electricity, Hydrogen, and Thermal Energy

    E-Print Network [OSTI]

    Lipman, Timothy; Brooks, Cameron

    2006-01-01

    Partnership Finalizes Hydrogen Energy Roadmap,” World WideCommercialization Strategy for Hydrogen Energy Technologies,Economic Analysis of Hydrogen Energy Station Concepts: Are “

  13. Next Generation Hydrogen Stations: All Composite Data Products through Fall 2012

    SciTech Connect (OSTI)

    Sprik, S.; Wipke, K.; Ramsden, T.; Ainscough, C.; Kurtz, J.

    2012-10-01

    This presentation from the U.S. Department of Energy's National Renewable Energy Laboratory includes 14 composite data products (CDPs) for next generation hydrogen stations.

  14. Converting Limbo Lands to Energy-Generating Stations: Renewable Energy Technologies on Underused, Formerly Contaminated Sites

    SciTech Connect (OSTI)

    Mosey, G.; Heimiller, D.; Dahle, D.; Vimmerstedt, L.; Brady-Sabeff, L.

    2007-10-01

    This report addresses the potential for using 'Limbo Lands' (underused, formerly contaminated sites, landfills, brownfields, abandoned mine lands, etc. ) as sites for renewable energy generating stations.

  15. Case Study - The Challenge: Saving Energy at a Sewage Lift Station...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Through Pump System Modifications This case study explores how the City of Milford, Connecticut saved energy at the Welches Point sewage lift station. By adding a small booster...

  16. Next Generation Hydrogen Station Composite Data Products: Data through Quarter 4 of 2013

    SciTech Connect (OSTI)

    Sprik, S.; Kurtz, J.; Peters, M.

    2014-05-01

    This report includes 25 composite data products (CDPs) produced for next generation hydrogen stations, with data through quarter 4 of 2013.

  17. Clean Cities Launches iPhone App for Alternative Fueling Station...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Addthis iPhone users now have access to a free app that locates fueling stations offering alternative fuels, including electricity, natural gas, biodiesel, E85, propane, and...

  18. Low-Cost Methane Liquefaction Plant and Vehicle Refueling Station

    SciTech Connect (OSTI)

    B. Wilding; D. Bramwell

    1999-01-01

    The Idaho National Engineering and Environmental Laboratory (INEEL) is currently negotiating a collaborative effort with Pacific Gas and Electric (PG&E) that will advance the use of liquefied natural gas (LNG) as a vehicle fuel. We plan to develop and demonstrate a small-scale methane liquefaction plant (production of 5,000 to 10,000 gallons per day) and a low-cost ($150,000) LNG refueling station to supply fuel to LNG-powered transit buses and other heavy-duty vehicles. INEEL will perform the research and development work. PG&E will deploy the new facilities commercially in two demonstration projects, one in northern California, and one in southern California.

  19. Monitoring and optimization of energy consumption of base transceiver stations

    E-Print Network [OSTI]

    Spagnuolo, Antonio; Vetromile, Carmela; Formosi, Roberto; Lubritto, Carmine

    2015-01-01

    The growth and development of the mobile phone network has led to an increased demand for energy by the telecommunications sector, with a noticeable impact on the environment. Monitoring of energy consumption is a great tool for understanding how to better manage this consumption and find the best strategy to adopt in order to maximize reduction of unnecessary usage of electricity. This paper reports on a monitoring campaign performed on six Base Transceiver Stations (BSs) located central Italy, with different technology, typology and technical characteristics. The study focuses on monitoring energy consumption and environmental parameters (temperature, noise, and global radiation), linking energy consumption with the load of telephone traffic and with the air conditioning functions used to cool the transmission equipment. Moreover, using experimental data collected, it is shown, with a Monte Carlo simulation based on power saving features, how the BS monitored could save energy.

  20. Natural gas vehicle fueling station dispenser meter evaluations

    SciTech Connect (OSTI)

    Rowley, P.F.; Kriha, K.; Blazek, C.F. [Inst. of Gas Technology, Chicago, IL (United States)

    1995-12-31

    The Institute of Gas Technology (IGT) has constructed a multi-purpose meter evaluation facility capable of testing metering technologies for high flow rate and high pressure NGV dispenser applications. The objective of IGT`s meter evaluation program, sponsored by IGT`s Sustaining Membership Program and the Gas Research Institute, is to assist the industry in evaluating the performance and accuracy of currently available flowmeters that are being used or could be applied to CNG gas dispensing. These meters are tested at various flow rates and pressures to determine their performance under NGV fueling station operating conditions and to identify the performance characteristics and limitations for each meter. The metering technologies which are being evaluated under this program include Coriolis meter, sonic nozzle meter, and turbine meter designs.

  1. EIS-0215: Pinon Pine Power Project, Tracy Station, NV

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy (DOE) prepared this statement to assess the environmental and human health issues associated with the Pinon Pine Power Project, a proposed demonstration project that would be cost-shared by DOE and the Sierra Pacific Power Company (SPPCo.) under DOE's Clean Coal Technology Program. The proposed Federal action is for DOE to provide cost-shared funding support for the construction and operation of the Pinon Pine Power Project, a coal-fired power generating facility, which would be a nominal, 800-ton-per-day (104 megawatt (MW) gross generation) air-blown, Integrated Gasification Combined-Cycle plant proposed by SPPCo. at its Tracy Power Station near Reno, Nevada.

  2. Summary of monitoring station component evaluation project 2009-2011.

    SciTech Connect (OSTI)

    Hart, Darren M.

    2012-02-01

    Sandia National Laboratories (SNL) is regarded as a center for unbiased expertise in testing and evaluation of geophysical sensors and instrumentation for ground-based nuclear explosion monitoring (GNEM) systems. This project will sustain and enhance our component evaluation capabilities. In addition, new sensor technologies that could greatly improve national monitoring system performance will be sought and characterized. This work directly impacts the Ground-based Nuclear Explosion Monitoring mission by verifying that the performance of monitoring station sensors and instrumentation is characterized and suitable to the mission. It enables the operational monitoring agency to deploy instruments of known capability and to have confidence in operational success. This effort will ensure that our evaluation capabilities are maintained for future use.

  3. Ridge station eases Florida's waste-disposal problems

    SciTech Connect (OSTI)

    Swanekamp, R.

    1994-10-01

    Two results of Florida's continuing population growth are (1) a critical need for electricity, and (2) a solid-waste disposal crisis. During a recent winter cold snap, electric demand in one service territory surged 25% over generating capacity and 10% over net system capability. Rolling blackouts ensued. At the same time, Florida's fragile wetlands environment is suffering from years of unfettered development. Groundwater sources are contaminated, landfill space is scarce, and illegal tire dumps blight the landscape. The recently constructed Ridge generating station in Polk County, Fla. is addressing both the state's electrical and environmental needs. Ridge, which entered commercial operation in May, burns a unique mix of urban woodwaste and scrap tires to provide 45 MW of critically needed electricity while keeping large quantities of solid waste out of landfills. When pipeline construction at an adjacent landfill is completed, the facility also will burn the methane gases produced when garbage decomposes.

  4. Potential failure of steam generator tubes following a station blackout

    SciTech Connect (OSTI)

    Ward, L.W.; Palmrose, D.E.

    1994-12-31

    The U.S. Nuclear Regulatory Commission is considering changes to pressurized water reactor (PWR) requirements relating to steam generator tube plugging and repair criteria, including leakage monitoring. The proposed changes are known as the alternate tube plugging criteria (APC) and are intended to permit PWRs to operate with through-wall cracks in steam generator tubes subject to meeting a specified limit on predicted primary to secondary leakage under accident conditions. To assess the consequences of the alternate plugging criteria, analyses were performed for a station blackout sequence in which the reactor core melts while the reactor coolant system (RCS) remains at high pressure. Evaluations were conducted to investigate the potential for tube failure with and without secondary system depressurization. The excessive heat coupled with the high-pressure differentials across the steam generator tubes could result in creep rupture failure of the tubes during a severe accident, which could lead to a radiological release directly to the environment. In order to assess the safety significance of the APC, it is important to identify the level of steam generator tube leakage that can occur without challenging the previous study conclusions that steam generator creep failure will not occur prior to a surge line or hot-leg failure. To assess the effect of leakage on steam generator tube integrity during a core melt sequence with the RCS at high pressure and the secondary side of the steam generators pressurized and depressurized, an analysis was performed for a core melt event resulting from an unmitigated station blackout to identify the total steamenerator and tube leakage flow rates that could induce tube ruptures prior to other RCS boudary faliures that could depressurize the RCS.

  5. How to use Electric Vehicle (EV) Charging Stations at Mason Charging stations are located in the visitor section of the Mason Pond, Shenandoah, and Rappahannock

    E-Print Network [OSTI]

    these instructions to be able to use the charging stations here on campus. 1) You must register with ChargePoint. https://www.chargepoint.com/ 2) EVs must be registered under your account and you must have a valid

  6. License Amendment Request for Storing Exelon Sister Nuclear Stations Class B/C LLRW in the LaSalle Station Interim Radwaste Storage Facility - 13620

    SciTech Connect (OSTI)

    Azar, Miguel; Gardner, Donald A.; Taylor, Edward R.

    2013-07-01

    Exelon Nuclear (Exelon) designed and constructed an Interim Radwaste Storage Facility (IRSF) in the mid-1980's at LaSalle County Nuclear Station (LaSalle). The facility was designed to store low-level radioactive waste (LLRW) on an interim basis, i.e., up to five years. The primary reason for the IRSF was to offset lack of disposal in case existing disposal facilities, such as the Southeast Compact's Barnwell Disposal Facility in Barnwell, South Carolina, ceased accepting radioactive waste from utilities not in the Southeast Compact. Approximately ninety percent of the Radwaste projected to be stored in the LaSalle IRSF in that period of time was Class A, with the balance being Class B/C waste. On July 1, 2008 the Barnwell Disposal Facility in the Southeast Compact closed its doors to out of- compact Radwaste, which precluded LaSalle from shipping Class B/C Radwaste to an outside disposal facility. Class A waste generated by LaSalle is still able to be disposed at the 'Envirocare of Utah LLRW Disposal Complex' in Clive, Utah. Thus the need for utilizing the LaSalle IRSF for storing Class B/C Radwaste for an extended period, perhaps life-of-plant or more became apparent. Additionally, other Exelon Midwest nuclear stations located in Illinois that did not build an IRSF heretofore also needed extended Radwaste storage. In early 2009, Exelon made a decision to forward Radwaste from the Byron Nuclear Station (Byron), Braidwood Nuclear Station (Braidwood), and Clinton Nuclear Station (Clinton) to LaSalle's IRSF. As only Class B/C Radwaste would need to be forwarded to LaSalle, the original volumetric capacity of the LaSalle IRSF was capable of handling the small number of additional expected shipments annually from the Exelon sister nuclear stations in Illinois. Forwarding Class B/C Radwaste from the Exelon sister nuclear stations in Illinois to LaSalle would require an amendment to the LaSalle Station operating license. Exelon submitted the License Amendment Request (LAR) to NRC on January 6, 2010; NRC approved the LAR on July 21, 2011. A similar decision was made by Exelon in early 2009 to forward Radwaste from Limerick Nuclear Station to its sister station, the Peach Bottom Atomic Power Station; both in Pennsylvania. A LAR submittal to the NRC was also provided and NRC approval was received in 2011. (authors)

  7. SOARCA Peach Bottom Atomic Power Station Long-Term Station Blackout Uncertainty Analysis: Convergence of the Uncertainty Results

    SciTech Connect (OSTI)

    Bixler, Nathan E.; Osborn, Douglas M.; Sallaberry, Cedric Jean-Marie; Eckert-Gallup, Aubrey Celia; Mattie, Patrick D.; Ghosh, S. Tina

    2014-02-01

    This paper describes the convergence of MELCOR Accident Consequence Code System, Version 2 (MACCS2) probabilistic results of offsite consequences for the uncertainty analysis of the State-of-the-Art Reactor Consequence Analyses (SOARCA) unmitigated long-term station blackout scenario at the Peach Bottom Atomic Power Station. The consequence metrics evaluated are individual latent-cancer fatality (LCF) risk and individual early fatality risk. Consequence results are presented as conditional risk (i.e., assuming the accident occurs, risk per event) to individuals of the public as a result of the accident. In order to verify convergence for this uncertainty analysis, as recommended by the Nuclear Regulatory Commission’s Advisory Committee on Reactor Safeguards, a ‘high’ source term from the original population of Monte Carlo runs has been selected to be used for: (1) a study of the distribution of consequence results stemming solely from epistemic uncertainty in the MACCS2 parameters (i.e., separating the effect from the source term uncertainty), and (2) a comparison between Simple Random Sampling (SRS) and Latin Hypercube Sampling (LHS) in order to validate the original results obtained with LHS. Three replicates (each using a different random seed) of size 1,000 each using LHS and another set of three replicates of size 1,000 using SRS are analyzed. The results show that the LCF risk results are well converged with either LHS or SRS sampling. The early fatality risk results are less well converged at radial distances beyond 2 miles, and this is expected due to the sparse data (predominance of “zero” results).

  8. EIS-0435: Modification of the Groton Generation Station Interconnection Agreement, Brown County, South Dakota

    Broader source: Energy.gov [DOE]

    This EIS evaluates the environmental impacts of a proposal for DOE's Western Area Power Administration to modify its Large Generator Connection Agreement for the Groton Generation Station in Brown County, South Dakota. The modification would allow Basin Electric Power Cooperative, which operates the generation station, to produce power above the current operating limit of 50 average megawatts.

  9. Summer 2009 CULHAM STATION 0708 0739 0815 0902 1001 1601 1702 1732 1831 1932 2032 2202

    E-Print Network [OSTI]

    Summer 2009 CULHAM STATION 0708 0739 0815 0902 1001 1601 1702 1732 1831 1932 2032 2202 BANBURY / OXFORD / CULHAM / DIDCOT / READING / LONDON PADDINGTON CULHAM STATION 0617 0647 0712 0731 0806 0917 1517 money whilst also protecting the environment, Culham Science Centre has teamed up with Lift

  10. PRACTICAL SNOW DEPTH SAMPLING AROUND SIX SNOW TELEMETRY (SNOTEL) STATIONS IN COLORADO AND WYOMING, UNITED STATES

    E-Print Network [OSTI]

    Anderson, Charles W.

    THESIS PRACTICAL SNOW DEPTH SAMPLING AROUND SIX SNOW TELEMETRY (SNOTEL) STATIONS IN COLORADO Laituri Mazdak Arabi #12;ii ABSTRACT PRACTICAL SNOW DEPTH SAMPLING AROUND SIX SNOW TELEMETRY (SNOTEL. These stations measure snow depth (SD), snow water equivalent (SWE), air temperature and precipitation. To assess

  11. Pressures on Arizona Water and Energy Policy: Case Study of the Navajo Generating Station

    E-Print Network [OSTI]

    Fay, Noah

    , the Navajo Generating Station (NGS), that is among the dirtiest coal power plants in the country1 Pressures on Arizona Water and Energy Policy: Case Study of the Navajo Generating Station Sonya largest user of energy in the state of Arizona. It is powered by a coal plant in Northern Arizona

  12. Aalborg Universitet Flexible Local Load Controller for Fast ElectricVehicle Charging Station Supplemented

    E-Print Network [OSTI]

    Schaltz, Erik

    the charging patterns of EV batteries, thus prolonging their lifetime and increasing the drivers' comfort levelAalborg Universitet Flexible Local Load Controller for Fast ElectricVehicle Charging Station Controller for Fast ElectricVehicle Charging Station Supplemented with Flywheel Energy Storage System

  13. Aalborg Universitet Distributed Bus Signaling Control for a DC Charging Station with Multi Paralleled

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    been reported in order to verify the validity of proposed approach. Keywords--EV charging; flywheelAalborg Universitet Distributed Bus Signaling Control for a DC Charging Station with Multi., & Savaghebi, M. (2015). Distributed Bus Signaling Control for a DC Charging Station with Multi Paralleled

  14. Analysis of Cost-Effective Off-Board Hydrogen Storage and Refueling Stations

    SciTech Connect (OSTI)

    Ted Barnes; William Liss

    2008-11-14

    This report highlights design and component selection considerations for compressed gas hydrogen fueling stations operating at 5000 psig or 350 bar. The primary focus is on options for compression and storage – in terms of practical equipment options as well as various system configurations and how they influence delivery performance and station economics.

  15. Variability of Large Particle (>100 m) Export Around Station ALOHA: The C-MORE OPEREX Cruise

    E-Print Network [OSTI]

    Highlight Variability of Large Particle (>100 µm) Export Around Station ALOHA: The C-MORE OPEREX the formation and evolution of these bloom around Station ALOHA and their impact on particle export. Low wind was widespread, export production was localized. Optical measurements from an Underwater Video Profiler (UVP

  16. Pullman's Weather and Air Quality Station James O'Malley, Brian Lamb, Tom Jobson

    E-Print Network [OSTI]

    Collins, Gary S.

    Pullman's Weather and Air Quality Station James O'Malley, Brian Lamb, Tom Jobson Thanks, and to Dr. Shelley N. Pressley. To monitor air quality in Pullman, the Laboratory for Atmospheric Research at Washington State University has operated a combined air monitoring and weather station located on the roof

  17. Sei Vojany Station repowering reconstruction-assessment feasibility study. Volume 1. Export trade information

    SciTech Connect (OSTI)

    Not Available

    1992-01-01

    The feasibility study conducted for Slovensky Energeticky Podnik (Slovak Energy Production Company) (SEP) evaluates reconstruction, repowering, and expansion of SEP's Vojany Station (EVO). Previous evaluations, studies, station records, and technical data were reviewed and utilized as a part of the feasibility analysis. The study results recommend a time-phased implementation for the recommended solutions.

  18. Humanoid robots as a passive-social medium -a field experiment at a train station

    E-Print Network [OSTI]

    Kanda, Takayuki

    Humanoid robots as a passive-social medium - a field experiment at a train station ­ Kotaro Hayashi Ishiguro1&3 , Tsukasa Ogasawara1&2 , Norihiro Hagita1 1 ATR Intelligent Robotics and Communication Labs. 2-shiomi}@atr.jp, {satoshi, ishiguro}@ams.eng.osaka-u.ac.jp, ogasawar@is.naist.jp ABSTRACT (a) Robots as medium in station (b

  19. Control of Nonlinear Distributed Parameter Systems Goong Chen, Texas A&M University, College Station, Texas

    E-Print Network [OSTI]

    Zhou, Jianxin

    Control of Nonlinear Distributed Parameter Systems edited by Goong Chen, Texas A&M University, College Station, Texas Irena Lasiecka, University of Virginia, Charlottesville, Virginia Jianxin Zhou, Texas A&M University, College Station, Texas #12;iii Preface This volume is an outgrowth

  20. Fuel Retrieval Sub Project (FRS) Stuck Fuel Station Performance Test Data Report

    SciTech Connect (OSTI)

    THIELGES, J.R.

    2000-02-23

    This document provides the test data report for Stuck Fuel Station Performance Testing in support of the Fuel Retrieval Sub-Project. The stuck fuel station was designed to provide a means of cutting open a canister barrel to release fuel elements, etc.

  1. Angle stations in or for endless conveyor belts

    DOE Patents [OSTI]

    Steel, Alan (Glasgow, GB6)

    1987-04-07

    In an angle station for an endless conveyor belt, there are presented to each incoming run of the belt stationary curved guide members (18, 19) of the shape of a major segment of a right-circular cylinder and having in the part-cylindrical portion (16 or 17) thereof rectangular openings (15) arranged in parallel and helical paths and through which project small freely-rotatable rollers (14), the continuously-changing segments of the curved surfaces of which projecting through said openings (15) are in attitude to change the direction of travel of the belt (13) through 90.degree. during passage of the belt about the part-cylindrical portion (16 or 17) of the guide member (18 or 19). The rectangular openings (15) are arranged with their longer edges lengthwise of the diagonals representing the mean of the helix but with those of a plurality of the rows nearest to each end of the part-cylindrical portion (16 or 17) slightly out of axial symmetry with said diagonals, being slightly inclined in a direction about the intersections (40) of the diagonals of the main portion of the openings, to provide a "toe-in" attitude in relation to the line of run of the endless conveyor belt.

  2. Renewable Energy Optimization Report for Naval Station Newport

    SciTech Connect (OSTI)

    Robichaud, R.; Mosey, G.; Olis, D.

    2012-02-01

    In 2008, the U.S. Environmental Protection Agency (EPA) launched the RE-Powering America's Land initiative to encourage the development of renewable energy (RE) on potentially contaminated land and mine sites. As part of this effort, EPA is collaborating with the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory (NREL) to evaluate RE options at Naval Station (NAVSTA) Newport in Newport, Rhode Island. NREL's Renewable Energy Optimization (REO) tool was utilized to identify RE technologies that present the best opportunity for life-cycle cost-effective implementation while also serving to reduce energy-related carbon dioxide emissions and increase the percentage of RE used at NAVSTA Newport. The technologies included in REO are daylighting, wind, solar ventilation preheating (SVP), solar water heating, photovoltaics (PV), solar thermal (heating and electric), and biomass (gasification and cogeneration). The optimal mix of RE technologies depends on several factors including RE resources; technology cost and performance; state, utility, and federal incentives; and economic parameters (discount and inflation rates). Each of these factors was considered in this analysis. Technologies not included in REO that were investigated separately per NAVSTA Newport request include biofuels from algae, tidal power, and ground source heat pumps (GSHP).

  3. Biomechanics of single cortical neurons

    E-Print Network [OSTI]

    Bernick, Kristin B.

    This study presents experimental results and computational analysis of the large strain dynamic behavior of single neurons in vitro with the objective of formulating a novel quantitative framework for the biomechanics of ...

  4. Estimates of Energy Cost Savings Achieved from 2009 IECC Code-Compliant, Single Family Residences in Texas 

    E-Print Network [OSTI]

    Kim, H.; Baltazar, J. C.; Haberl, J.

    2011-01-01

    -01-01 ESTIMATES OF ENERGY COST SAVINGS ACHIEVED FROM 2009 IECC CODE-COMPLIANT, SINGLE-FAMILY RESIDENCES IN TEXAS Hyojin Kim Juan-Carlos Baltazar, Ph.D. Jeff Haberl, Ph.D., P.E. January 2011 (Revised...) ENERGY SYSTEMS LABORATORY Texas Engineering Experiment Station Texas A&M University System 2009 IECC Cost Savings Report, p.i January 2011 Energy Systems Laboratory, Texas A&M University EXECUTIVE SUMMARY This report presents estimates...

  5. Single nanoparticle tracking spectroscopic microscope

    DOE Patents [OSTI]

    Yang, Haw (Moraga, CA); Cang, Hu (Berkeley, CA); Xu, Cangshan (Berkeley, CA); Wong, Chung M. (San Gabriel, CA)

    2011-07-19

    A system that can maintain and track the position of a single nanoparticle in three dimensions for a prolonged period has been disclosed. The system allows for continuously imaging the particle to observe any interactions it may have. The system also enables the acquisition of real-time sequential spectroscopic information from the particle. The apparatus holds great promise in performing single molecule spectroscopy and imaging on a non-stationary target.

  6. Abstract--In Universal Mobile Telecommunication System (UMTS), the downlink capacity is limited by the base station

    E-Print Network [OSTI]

    by the base station transmission power. Therefore, power control plays an important role to minimize the available power resources of UMTS base stations to MBMS sessions running in the network. Furthermore stations to support many simultaneous MBMS sessions. MBMS transmissions have increased power requirements

  7. BEAM-POWER DEPOSITION IN A 4-MW TARGET STATION FOR A MUON COLLIDER OR A NEUTRINO FACTORY

    E-Print Network [OSTI]

    McDonald, Kirk

    BEAM-POWER DEPOSITION IN A 4-MW TARGET STATION FOR A MUON COLLIDER OR A NEUTRINO FACTORY (IPAC11 with shielding out to 1.2 m radius. W-C shielding likely needed beyond the target station, where ~ 800 kW power-carbide + water shielding of superconducting magnets for the target station at a Muon Collider or Neutrino Factory

  8. Electrical transient stability and underfrequency load shedding analysis for a large pump station

    SciTech Connect (OSTI)

    Shilling, S.R. [Saudi Aramco, Dhahran (Saudi Arabia)

    1995-12-31

    Electrical transients from faults, loss of generation, and load swings can disrupt pump station operations. Isolated stations with no utility tie and those with weak utility ties are especially at risk. Relative to this problem, the following four main issues are addressed: (1) Analyze the methods that use high-speed underfrequency load shedding to maintain system stability and preserve station operations. (2) Analyze combustion gas turbine generator and diesel generator transient responses, as they pertain to the Electrical Engineer. (3) Discuss system component modeling and the use of low voltage circuit switching devices to shed loads. (4) Compare two computer analysis program outputs for underfrequency load shedding responses.

  9. Electrical transient stability and underfrequency load shedding analysis for a large pump station

    SciTech Connect (OSTI)

    Shilling, S.R. [Saudi Aramco, Dhahran (Saudi Arabia)] [Saudi Aramco, Dhahran (Saudi Arabia)

    1997-01-01

    Electrical transients from faults, loss of generation, and load swings can disrupt pump station operations. Isolated stations with no utility tie, and those with weak utility ties, are especially at risk. Relative to this problem, the following four main issues are addressed: (1) analyze the methods that use high-speed underfrequency load shedding to maintain system stability and preserve station operations; (2) analyze combustion gas turbine generator and diesel generator transient responses, as they pertain to the electrical engineer; (3) discuss system component modeling and the use of low voltage circuit switching devices to shed loads; (4) compare two computer analysis program outputs for underfrequency load shedding responses.

  10. Integrated TRAC/MELPROG analyses of a PWR station blackout

    SciTech Connect (OSTI)

    Henninger, R.; Dearing, J.F.

    1987-01-01

    The first complete, coupled, and largely mechanistic analysis of the entire reactor-coolant system during a station blackout (TMLB') core-meltdown accident has been made with MELPROG/TRAC. The calculation was initiated at the start of the transient and ended with a late recovery of cooling. Additional cooling provided by water from the primary system delayed events relative to a standalone MELPROG calculation. Natural circulation within the vessel was established and primary-relief-valve action did little to disturb this flow. In addition, it was calculated directly that the hot leg reached a failure temperature long before vessel failure. Beyond relocation of the core, we have calculated the boiloff of the water in the lower head and have estimated the time of vessel failure to be at about 14,700 s into the transient. For ''nominal'' corium-water heat transfer, the boiloff process (steam-production rate) is slow enough that the relief valves prevent pressurization beyond 17.5 MPa. Parametric cases with increased corium-water heat transfer resulted in steaming rates beyond the capability of the relief valves, leading to pressures in excess of 19.2 MPa. Natural convection flow around the loop, if started by removing the water in the loop seal, was blocked by a relatively less-dense hydrogen/steam mixture that flowed to the top of the steam generator. Emergency core-cooling system activation late in the transient (after core slump) resulted in rapid cooling of the periphery of the debris region but slower cooling in the interior regions because of poor water penetration.

  11. Enhancement of NRC station blackout requirements for nuclear power plants

    SciTech Connect (OSTI)

    McConnell, M. W.

    2012-07-01

    The U.S. Nuclear Regulatory Commission (NRC) established a Near-Term Task Force (NTTF) in response to Commission direction to conduct a systematic and methodical review of NRC processes and regulations to determine whether the agency should make additional improvements to its regulatory system and to make recommendations to the Commission for its policy direction, in light of the accident at the Fukushima Dai-ichi Nuclear Power Plant. The NTTF's review resulted in a set of recommendations that took a balanced approach to defense-in-depth as applied to low-likelihood, high-consequence events such as prolonged station blackout (SBO) resulting from severe natural phenomena. Part 50, Section 63, of Title 10 of the Code of Federal Regulations (CFR), 'Loss of All Alternating Current Power,' currently requires that each nuclear power plant must be able to cool the reactor core and maintain containment integrity for a specified duration of an SBO. The SBO duration and mitigation strategy for each nuclear power plant is site specific and is based on the robustness of the local transmission system and the transmission system operator's capability to restore offsite power to the nuclear power plant. With regard to SBO, the NTTF recommended that the NRC strengthen SBO mitigation capability at all operating and new reactors for design-basis and beyond-design-basis external events. The NTTF also recommended strengthening emergency preparedness for prolonged SBO and multi-unit events. These recommendations, taken together, are intended to clarify and strengthen US nuclear reactor safety regarding protection against and mitigation of the consequences of natural disasters and emergency preparedness during SBO. The focus of this paper is on the existing SBO requirements and NRC initiatives to strengthen SBO capability at all operating and new reactors to address prolonged SBO stemming from design-basis and beyond-design-basis external events. The NRC initiatives are intended to enhance core and spent fuel pool cooling, reactor coolant system integrity, and containment integrity. (authors)

  12. Study of a Station Blackout Event in the PWR Plant

    SciTech Connect (OSTI)

    Ching-Hui Wu; Tsu-Jen Lin; Tsu-Mu Kao [Institute of Nuclear Energy Research P.O. Box 3-3, Longtan, 32500, Taiwan (China)

    2002-07-01

    On March 18, 2001, a PWR nuclear power plant located in the Southern Taiwan occurred a Station Blackout (SBO) event. Monsoon seawater mist caused the instability of offsite power grids. High salt-contained mist caused offsite power supply to the nuclear power plant very unstable, and forced the plant to be shutdown. Around 24 hours later, when both units in the plant were shutdown, several inadequate high cycles of bus transfer between 345 kV and 161 kV startup transformers degraded the emergency 4.16 kV switchgears. Then, in the Train-A switchgear room of Unit 1 occurred a fire explosion, when the degraded switchgear was hot shorted at the in-coming 345 kV breaker. Inadequate configuration arrangement of the offsite power supply to the emergency 4.16 kV switchgears led to loss of offsite power (LOOP) events to both units in the plant. Both emergency diesel generators (EDG) of Unit 1 could not be in service in time, but those of Unit 2 were running well. The SBO event of Unit 1 lasted for about two hours till the fifth EDG (DG-5) was lined-up to the Train-B switchgear. This study investigated the scenario of the SBO event and evaluated a risk profile for the SBO period. Guidelines in the SBO event, suggested by probabilistic risk assessment (PRA) procedures were also reviewed. Many related topics such as the re-configuration of offsite power supply, the addition of isolation breakers of the emergency 4.16 kV switchgears, the betterment of DG-5 lineup design, and enhancement of the reliability of offsite power supply to the PWR plant, etc., will be in further studies. (authors)

  13. Corrective Action Decision Document for Corrective Action Unit 321: Area 22 Weather Station Fuel Storage, Nevada Test Site, Nevada

    SciTech Connect (OSTI)

    U.S. Department of Energy, Nevada Operations Office

    1999-07-22

    This Corrective Action Decision Document identifies and rationalizes the U.S. Department of Energy, Nevada Operations Office's selection of a recommended corrective action alternative appropriate to facilitate the closure of Corrective Action Unit (CAU) 321, Weather Station Fuel Storage, under the Federal Facility Agreement and Consent Order. Corrective Action Unit 321 is located at the Nevada Test Site (NTS) in Area 22, and consists of a single Corrective Action Site (CAS) 22-99-05, Fuel Storage Area. This CAS contains a fuel storage area approximately 325 by 540 feet, which was used to store fuel and other petroleum products necessary for motorized operations at the historical Camp Desert Rock facility, which was operational from 1951 to 1958. The corrective action investigation conducted in February 1999 found the only contaminant of concern above preliminary action levels to be total petroleum hydrocarbons as diesel-range organics at two sample locations. During this investigation, the two corrective action objectives identified were (1) to prevent or mitigate exposure to near-surface soil containing contaminants of concern, and (2) to prevent spread of contaminants of concern beyond the corrective action unit. Based on the corrective action objectives, the two corrective action alternatives developed for consideration were: Alternative 1 - No Further Action; and Alternative 2 - Clean Closure by Excavation and Disposal. The two alternatives were evaluated based on four general corrective action standards and five remedy selection decision factors, and the preferred corrective action alternative chosen on technical merit, focusing on performance, reliability, feasibility, and safety was Alternative 2. This alternative meets all applicable state and federal regulations for closure of the site and will eliminate potential future exposure pathways to the contaminated soils at the Weather Station Fuel Storage site.

  14. Analysis of the Use of Wind Energy to Supplement the Power Needs at McMurdo Station and Amundsen-Scott South Pole Station, Antarctica (Poster)

    SciTech Connect (OSTI)

    Baring-Gould, E. I.; Robichaud, R.; McLain, K.

    2005-05-01

    This poster summarizes the analysis of the inclusion of wind-driven power generation technology into the existing diesel power plants at two U.S. Antarctic research stations, McMurdo and Amundsen-Scott South Pole Station. Staff at the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the analysis. Available data were obtained on the wind resources, power plant conditions, load, and component cost. We then used NREL's Hybrid2 power system modeling software to analyze the potential and cost of using wind turbine generators at the two aforementioned facilities.

  15. Design and installation of continuous flow and water quality monitoring stations to improve water quality forecasting in the lower San Joaquin River

    E-Print Network [OSTI]

    Quinn, Nigel W.T.

    2007-01-01

    CONTINUOUS FLOW, EC AND TEMPERATURE MONITORING STATIONS FORMonitoring Group Name Your Name Date Parameter Temperature onutrients, temperature) 4. Existing monitoring stations

  16. Retrofit of Tehran City Gate Station C.G.S. No. 2 by Using Turboexpander 

    E-Print Network [OSTI]

    Seresht, R. T.; Ja, H. K.

    2010-01-01

    air components. 6. Liquefaction gases (like Helium). 7. Separating condensable components of natural gas. 8. Power generation from geothermal energy. Retrofit of Tehran City Gate Station C.G.S. No.2 by Using Turboexpander Yasun Farayand Company...

  17. ETM (Distribution Network Automation on 10 kV cable line stations...

    Open Energy Info (EERE)

    ETM (Distribution Network Automation on 10 kV cable line stations) (Smart Grid Project) Jump to: navigation, search Project Name ETM (Distribution Network Automation on 10 kV cable...

  18. Design principles for the development of space technology maturation laboratories aboard the International Space Station

    E-Print Network [OSTI]

    Saenz Otero, Alvar, 1975-

    2005-01-01

    This thesis formulates seven design principles for the development of laboratories which utilize the International Space Station (ISS) to demonstrate the maturation of space technologies. The principles are derived from ...

  19. A lean safety review process for payloads on the International Space Station

    E-Print Network [OSTI]

    Luis, Javier de

    2003-01-01

    The International Space Station has the potential to serve as a unique test platform to enable technologies for a wide array of manned and unmanned NASA missions. In order to live up to its promise, the resources required ...

  20. Webinar: Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project

    Broader source: Energy.gov [DOE]

    Text version and video recording of the webinar titled "An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project," originally presented on November 18, 2014.

  1. Hydrogen Energy Stations: Poly-Production of Electricity, Hydrogen, and Thermal Energy

    E-Print Network [OSTI]

    Lipman, Timothy; Brooks, Cameron

    2006-01-01

    y d r o g e n Energy Stations New York State Energy Researchin an effort led by the New York State Energy Research andNYSERDA) (2005), “New York Hydrogen Energy Roadmap,” NYSERDA

  2. Pollen Dispersion in Relation to Meteorological Conditions, Seasonality, Location and Elevation in College Station, Texas, USA 

    E-Print Network [OSTI]

    Huang, Kristen

    2012-04-30

    meteorological factors, including temperature, relative humidity, solar radiation, pressure, rain, wind speed and wind direction. A biological microscope was used for identification of possible common species in College Station, Texas. Insight into the vertical...

  3. Overview of Station Analysis Tools Developed in Support of H2USA

    Broader source: Energy.gov [DOE]

    Access the recording and download presentation slides from the Fuel Cell Technologies Office webinar "Overview of Station Analysis Tools Developed in Support of H2USA" held on May 12, 2015.

  4. 2013/2014 Biennial Report Smithsonian Marine Station at Fort Pierce

    E-Print Network [OSTI]

    Miller, Scott

    , a thermocycler for DNA amplification, high-performance liquid chromatographs, a gas chromatograph/ mass spect The facility is a field station of the Smithsonian Institution, administered by the National Museum of Natural

  5. Fact #874: May 25, 2015 Number of Electric Stations and Electric...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    fuel (10,710 stations). The number of charging units is of particular importance for electric vehicles due to the length of time it takes vehicles to charge compared to other...

  6. A chondrule-like object captured by space-exposed aerogel on the international space station

    E-Print Network [OSTI]

    Meyers, Stephen R.

    A chondrule-like object captured by space-exposed aerogel on the international space station T (Bradley, 2004; Brownlee, 1985). On the other hand, MMs are collected by melting and filtering of Antarctic

  7. Radiological characterization of main cooling reservoir bottom sediments at The South Texas Project Electrical Generating Station 

    E-Print Network [OSTI]

    Blankinship, David Randle

    1993-01-01

    The South Texas Project Electrical Generating Station (STPEGS operating license directs that an effective radiological environmental monitoring program be established. Site- specific data should then augment the generation of an accurate dose model...

  8. Near optimal design of fixture layouts in multi-station assembly processes 

    E-Print Network [OSTI]

    Kim, Pansoo

    2004-11-15

    annealing, genetic algorithm, the data-mining method performs the best and the revised exchange algorithm performs comparably to simulated annealing, but better than the others. A four-station assembly process for a sport utility vehicle (SUV) side frame...

  9. Hydrogen Energy Stations: Poly-Production of Electricity, Hydrogen, and Thermal Energy

    E-Print Network [OSTI]

    Lipman, Timothy; Brooks, Cameron

    2006-01-01

    www.cleanegroup.org. Connecticut Clean Energy Fund (2004),NETL-2002/1179, November. Clean Energy Group l 29 l H y de n Energy Stations Clean Energy Group (CEG) is a nonprofit

  10. Hydrogen Energy Stations: Poly-Production of Electricity, Hydrogen, and Thermal Energy

    E-Print Network [OSTI]

    Lipman, Timothy; Brooks, Cameron

    2006-01-01

    www.cleanegroup.org. Connecticut Clean Energy Fund (2004),DOE/NETL-2002/1179, November. Clean Energy Group l 29 l H yd r o g e n Energy Stations Clean Energy Group (CEG) is a

  11. Fuel Cell Demonstration at the U.S. Coast Guard Air Station Cape Cod

    SciTech Connect (OSTI)

    Halverson, Mark A.; Chvala, William D.; Herrera, Shawn

    2005-07-30

    Journal article reporting on the 250-kW fuel cell combined heat and power plant located at the U.S. Coast Guard Air Station Cape Code in Bourne, Massachusetts.

  12. Webinar: An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project

    Broader source: Energy.gov [DOE]

    The Energy Department will present a live webinar entitled "An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project" on Tuesday, November 18, from 12:00...

  13. PLC Software Program for Leak Detector Station A1 SALW-LD-ST-A1

    SciTech Connect (OSTI)

    KOCH, M.R.

    2001-01-25

    This document describes the software program for the programmable logic controller for the leak detector station ''SALW-LD-ST-A1''. The appendices contains a copy of the printout of the software program.

  14. A performance-driven experiment framework for space technology development using the International Space Station

    E-Print Network [OSTI]

    Hilton, Andrew Robert

    2015-01-01

    Space systems are inherently difficult to verify prior to launch due to the challenges of replicating the space environment through ground testing. The SPHERES testbed on the International Space Station has provided a ...

  15. Analysis of Energy Consumption of Duplex Residences in College Station, Texas 

    E-Print Network [OSTI]

    Kim, S. B.; Woods, P. K.

    1998-01-01

    This paper characterizes the variability of energy consumption due to a series of construction, occupant, and weather-related effects in duplex residences in College Station, Texas. In this paper, spline regression was used to estimate cooling...

  16. Between stations and habitations : the architecture of French science at the shore, 1830-1900

    E-Print Network [OSTI]

    Eigen, Edward

    2000-01-01

    This dissertation introduces a group of mutable institutions of research which emerged along the coast of France in the nineteenth century. The setting of these stations gave rise to a manner of occupation, both in the ...

  17. Sei Vojany Station repowering reconstruction assessment feasibility study. Volume 3. Export trade information

    SciTech Connect (OSTI)

    Not Available

    1992-01-01

    The feasibility study conducted for Slovensky Energeticky Podnik(Slovak Energy Production Company) (SEP) evaluates reconstruction, repowering, and expansion of SEP's Vojany Station(EVO). The study recommends a training program for government and plant officials.

  18. Acceptance and operability test report for the 327 building retention process sewer diverter station

    SciTech Connect (OSTI)

    Olander, A.R.

    1996-09-04

    This test report includes the results of acceptance and operability testing of the 327 building diverter station. The test included steps for flushing, calibrating, and operating the system on backup power.

  19. Acceptance {ampersand} operability test report for the 324 building retention process sewer diverter station

    SciTech Connect (OSTI)

    Olander, A.R.

    1996-09-04

    This test report includes the results of acceptance and operability testing of the 324 building diverter station. The test included steps for flushing, calibrating, and operating the system on backup power.

  20. After the gas station : redevelopment opportunities from rethinking America's vehicle refueling infrastructure

    E-Print Network [OSTI]

    Turco, Andrew

    2014-01-01

    Gas stations are found throughout the US, but their ubiquity causes them to go largely unnoticed. Because their purpose - refueling vehicles - is so uniform and so integral to the existing automotive transportation system, ...

  1. Environmental design guidelines for a second generation, LEO, permanently manned space station

    E-Print Network [OSTI]

    Johnson, David Michael, 1960-

    1987-01-01

    This thesis is a continuation of the thoughts and efforts of the author's participation and co-organization of the Space Station Design Workshop (SSDW). The SSDW was a student run event whose inception surfaced in the ...

  2. Determination of a peak benzene exposure to consumers at typical self-service gasoline stations 

    E-Print Network [OSTI]

    Carapezza, Ted

    1977-01-01

    DETERMINATION OF A PEAK BENZENE EXPOSURE TO CONSUMERS AT TYPICAL SELF-SERVICE GASOLINE STATIONS A Thesis by TED CARAPEZZA Submitted to the Graduate College of Texas A8M University in Partial fulfillment of the requirement for the degree... of MASTER OF SCIENCE December 1977 Major Subject: Industrial Hygiene DETERMINATION OF A PEAK BENZENE EXPOSURE TO CONSUMERS AT TYPICAL SELF-SERVICE GASOLINE STATIONS A Thesis by TED CARAPEZZA Approved as to style and content by: (. (iL, &? Chairman...

  3. Investigation of waste rag generation at Naval Station Mayport. Project report, May 1990-July 1993

    SciTech Connect (OSTI)

    1995-08-01

    The report presents the results of an investigation examining pollution prevention alternatives for reducing the volume of waste rags generated at Naval Station Mayport, located near Jacksonville Beach, Florida. The report recommends five specific pollution prevention alternatives: better operating practices, installation of equipment cleaning stations to remove contaminants normally removed with rags; replacement of SERVE MART rags with disposable wipers; use of recyclable rats for oil and great removal; and confirmation that used rags are fully contaminated prior to disposal.

  4. Evaluation of moisture sensors for NGV fueling station applications. Topical report, November 1994-April 1996

    SciTech Connect (OSTI)

    Rowley, P.F.; Maniquis, V.T.; Hunecke, D.E.; Blazek, C.F.

    1996-08-01

    Moisture content in natural gas has become an important issue for compressed natural gas (CNG) fueling stations. The objective of this project was to evaluate the performance of four hygrometer technologies and identify the most cost effective designs suitable for CNG fueling station applications. The four technologies evaluated were: aluminum oxide, ceramic dewpoint, electrolytic, and silicon chip sensors. The hygrometer performance was evaluated with respect to accuracy, response time, repeatability, operating conditions, maintenance requirements, and cost.

  5. Design, Modeling and Testing of the Askaryan Radio Array South Pole Autonomous Renewable Power Stations

    E-Print Network [OSTI]

    Besson, D Z; Ratzlaff, K; Young, R

    2014-01-01

    We describe the design, construction and operation of the Askaryan Radio Array (ARA) Autonomous Renewable Power Stations, initially installed at the South Pole in December, 2010 with the goal of providing an independently operating 100 W power source capable of year-round operation in extreme environments. In addition to particle astrophysics applications at the South Pole, such a station can easily be, and has since been, extended to operation elsewhere, as described herein.

  6. A Study of Municipal Funding of Nonprofit Agencies for the City of College Station, Texas 

    E-Print Network [OSTI]

    Dempsey, Sarah; Finegan, Kyle; Joong Kim, Dae; Li, Ying; Manna, Susan; Williamson, Michael Eli

    2009-01-01

    services (nonprofits) according to Department of Housing and Urban Development (HUD) regulations. City of College Station Nonprofit Contracting and Accountability The City of College Station enters into formal contracts with agencies approved... generally result in changes to nonprofit funding. CDBG contracting operates based solely upon HUD guidelines and is therefore subject to federally designated reporting and performance 8 measures. The City must adhere to all HUD regulations...

  7. Fuel Retrieval Sub (FRS) Project Decapping Station Performance Test Data Report

    SciTech Connect (OSTI)

    THIELGES, J.R.

    2000-01-13

    This document is to provide the test data report for Decapping Station Performance Testing. These performance tests were full scale and viewed as a continuation of development testing performed earlier (SNF-2710). A prototype decapping station confinement box was tested, along with some special tools required for the process, providing assurance that the fuel handling equipment will operate as designed, allowing for release of the FRS equipment for installation.

  8. Single-photon decision maker

    E-Print Network [OSTI]

    Naruse, Makoto; Drezet, Aurelien; Huant, Serge; Aono, Masashi; Hori, Hirokazu; Kim, Song-Ju

    2015-01-01

    Decision making is critical in our daily lives and for society in general and is finding evermore practical applications in information and communication technologies. Herein, we demonstrate experimentally that single photons can be used to make decisions in uncertain, dynamically changing environments. Using a nitrogen-vacancy in a nanodiamond as a single-photon source, we demonstrate the decision-making capability by solving the multi-armed bandit problem. This capability is directly and immediately associated with single-photon detection in the proposed architecture, leading to adequate and adaptive autonomous decision making. This study makes it possible to create systems that benefit from the quantum nature of light to perform practical and vital intelligent functions.

  9. Single-Photon Molecular Cooling

    E-Print Network [OSTI]

    Edvardas Narevicius; S. Travis Bannerman; Mark G. Raizen

    2009-01-04

    We propose a general method to cool the translational motion of molecules. Our method is an extension of single photon atomic cooling which was successfully implemented in our laboratory. Requiring a single event of absorption followed by a spontaneous emission, this method circumvents the need for a cycling transition and can be applied to any paramagnetic or polar molecule. In our approach, trapped molecules would be captured near their classical turning points in an optical dipole or RF-trap following an irreversible transition process.

  10. Single-cycle nonlinear optics

    E-Print Network [OSTI]

    Goulielmakis, E.; Max-Planck-Institut fur Quantenoptik

    2008-01-01

    g l e - C y c l e Nonlinear Optics E. G o u l i e l m a k iSingle-Cycle Nonlinear Optics E. Goulielmakis *, M.D-85748 Garching. Center for X-Ray Optics, Lawrence Berkeley

  11. Single element laser beam shaper

    DOE Patents [OSTI]

    Zhang, Shukui (Yorktown, VA); Michelle D. Shinn (Newport News, VA)

    2005-09-13

    A single lens laser beam shaper for converting laser beams from any spatial profile to a flat-top or uniform spatial profile. The laser beam shaper includes a lens having two aspheric surfaces. The beam shaper significantly simplifies the overall structure in comparison with conventional 2-element systems and therefore provides great ease in alignment and reduction of cost.

  12. A single-molecule approach to ZnO defect studies: Single photons and single defects

    SciTech Connect (OSTI)

    Jungwirth, N. R.; Pai, Y. Y.; Chang, H. S.; MacQuarrie, E. R.; Nguyen, K. X.; Fuchs, G. D.

    2014-07-28

    Investigations that probe defects one at a time offer a unique opportunity to observe properties and dynamics that are washed out of ensemble measurements. Here, we present confocal fluorescence measurements of individual defects in ZnO nanoparticles and sputtered films that are excited with sub-bandgap energy light. Photon correlation measurements yield both antibunching and bunching, indicative of single-photon emission from isolated defects that possess a metastable shelving state. The single-photon emission is in the range of ?560–720?nm and typically exhibits two broad spectral peaks separated by ?150?meV. The excited state lifetimes range from 1 to 13?ns, consistent with the finite-size and surface effects of nanoparticles and small grains. We also observe discrete jumps in the fluorescence intensity between a bright state and a dark state. The dwell times in each state are exponentially distributed and the average dwell time in the bright (dark) state does (may) depend on the power of the exciting laser. Taken together, our measurements demonstrate the utility of a single-molecule approach to semiconductor defect studies and highlight ZnO as a potential host material for single-defect based applications.

  13. TEM study of PM2.5 emitted from coal and tire combustion in a thermal power station

    SciTech Connect (OSTI)

    Reto Giere; Mark Blackford; Katherine Smith

    2006-10-15

    The research presented here was conducted within the scope of an experiment investigating technical feasibility and environmental impacts of tire combustion in a coal-fired power station. Previous work has shown that combustion of a coal + tire blend rather than pure coal increased bulk emissions of various elements (e.g., Zn, As, Sb, Pb). The aim of this study is to characterize the chemical and structural properties of emitted single particles with dimensions <2.5 {mu}m (PM2.5). This transmission electron microscope (TEM)-based study revealed that, in addition to phases typical of coal fly ash (e.g., aluminum-silicate glass, mullite), the emitted PM2.5 contains amorphous selenium particles and three types of crystalline metal sulfates never reported before from stack emissions. Anglesite, PbSO{sub 4}, is ubiquitous in the PM2.5 derived from both fuels and contains nearly all Pb present in the PM. Gunningite, ZnSO{sub 4}H{sub 2}O, is the main host for Zn and only occurs in the PM derived from the coal + tire blend, whereas yavapaiite, KFe{sup 3+}(SO{sub 4}){sub 2}, is present only when pure coal was combusted. It is concluded that these metal sulfates precipitated from the flue gas may be globally abundant aerosols and have, through hydration or dissolution, a major environmental and health impact. 66 refs., 2 figs., 1 tab.

  14. On Deployment of Multiple Base Stations for Energy-Efficient Communication in Wireless Sensor Networks

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Lin, Yunyue; Wu, Qishi; Cai, Xiaoshan; Du, Xiaojiang; Kwon, Ki-Hyeon

    2010-01-01

    Data transmission from sensor nodes to a base station or a sink node often incurs significant energy consumption, which critically affects network lifetime. We generalize and solve the problem of deploying multiple base stations to maximize network lifetime in terms of two different metrics under one-hop and multihop communication models. In the one-hop communication model, the sensors far away from base stations always deplete their energy much faster than others. We propose an optimal solution and a heuristic approach based on the minimal enclosing circle algorithm to deploy a base station at the geometric center of each cluster. In themore »multihop communication model, both base station location and data routing mechanism need to be considered in maximizing network lifetime. We propose an iterative algorithm based on rigorous mathematical derivations and use linear programming to compute the optimal routing paths for data transmission. Simulation results show the distinguished performance of the proposed deployment algorithms in maximizing network lifetime.« less

  15. Single Top production at CMS

    E-Print Network [OSTI]

    Thomas Speer

    2011-10-11

    A first measurement of the cross section of single top quark production in the t channel in pp collision at sqrt(s)=7 TeV is presented. The measurement is performed on a data sample corresponding to an integrated luminosity of 35.9 pb^-1 recorded at the LHC with the CMS detector. Leptonic decay channels with an electron or a muon in the final state are considered. After a selection optimized for the t-channel mode, two different and complementary analyses have been performed. Both analyses confirm the Tevatron's observation of single top, and their combination measures a cross section of sigma = 83.6 +/- 29.8(stat.+syst.) +/- 3.3 (lumi.) pb, which is consistent with the Standard Model prediction.

  16. Construction and installation summary for fiscal year 1992 of the hydraulic head monitoring stations at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    SciTech Connect (OSTI)

    Dreier, R.B.; Switek, J.; Couzens, B.A.

    1992-12-01

    During FY 1992, as part of the Hydraulic Head Monitoring Station (HHMS) Project, three multiport wells (HHMS 12, 13, and 14) were constructed along or near the boundaries of Waste Area Grouping (WAG) 2 at Haw Ridge water gap. The purpose of this report is to document well construction and multiport component installation activities. The hydraulic head monitoring stations (HHMS) are well clusters and single multiport wells that provide data required for evaluation of the transition between shallow and deep groundwater systems and of the nature of these systems. This information is used for required characterization of the hydrologic framework as dictated by state and federal regulatory agencies. Groundwater contaminants may move laterally across WAG boundaries or offsite; they may also move in a vertical direction. Because the HHMS Project was designed to address otential contamination problems, the project provides a means for defining the bounds of the uppermost aquifer; identifying potential pathways for offsite contamination for shallow; intermediate, and deep groundwater flow; and evaluating the capacity for contaminant transport in intermediate and deep groundwater flow systems.

  17. Construction and installation summary for fiscal year 1992 of the hydraulic head monitoring stations at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    SciTech Connect (OSTI)

    Dreier, R.B.; Switek, J.; Couzens, B.A.

    1992-12-01

    During FY 1992, as part of the Hydraulic Head Monitoring Station (HHMS) Project, three multiport wells (HHMS 12, 13, and 14) were constructed along or near the boundaries of Waste Area Grouping (WAG) 2 at Haw Ridge water gap. The purpose of this report is to document well construction and multiport component installation activities. The hydraulic head monitoring stations (HHMS) are well clusters and single multiport wells that provide data required for evaluation of the transition between shallow and deep groundwater systems and of the nature of these systems. This information is used for required characterization of the hydrologic framework as dictated by state and federal regulatory agencies. Groundwater contaminants may move laterally across WAG boundaries or offsite; they may also move in a vertical direction. Because the HHMS Project was designed to address otential contamination problems, the project provides a means for defining the bounds of the uppermost aquifer; identifying potential pathways for offsite contamination for shallow; intermediate, and deep groundwater flow; and evaluating the capacity for contaminant transport in intermediate and deep groundwater flow systems.

  18. 14th Annual international meeting of wind turbine test stations: Proceedings

    SciTech Connect (OSTI)

    Not Available

    1994-11-01

    These proceedings are of the 14th Annual International Meeting of Test Stations. As the original charter states these meetings are intended to be an international forum for sharing wind turbine testing experiences. By sharing their experiences they can improve testing skills and techniques. As with all new industries the quality of the products is marked by how well they learn from their experiences and incorporate this learning into the next generation of products. The test station`s role in this process is to provide accurate information to the companies they serve. This information is used by designers to conform and improve their designs. It is also used by certification agencies for confirming the quality of these designs. By sharing of experiences they are able to accomplished these goals, serve these customers better and ultimately improve the international wind energy industry.

  19. CNG fueling stations: The dispenser and control benefits of a systems design

    SciTech Connect (OSTI)

    Sullivan, C.D.

    1995-12-31

    A CNG station is composed of many varied pieces of equipment. It is the combined functionality and compatibility of this equipment that distinguishes a CNG fueling system from a CNG fueling station. Components include: dryer, compressor, driver, cooler, blow-down system, priority/sequencing/bypass system; storage; dispenser; and controls. Whether its a system or a station, the objective is the same: to disperse the proper amount of clean dry compressed natural gas into a vehicle quickly. This objective is sometimes overshadowed by the focus on the compressor. It is big, tangible and usually costs the most. The compressor, however is only responsible for compressing the gas, not dispensing it into the vehicle. While there are many different types of compressors on the market, some of which are very good, this paper focuses on the system design and control and its specific effects on the dispensing system.

  20. An in situ measurement of the radio-frequency attenuation in ice at Summit Station, Greenland

    E-Print Network [OSTI]

    J. Avva; J. M. Kovac; C. Miki; D. Saltzberg; A. G. Vieregg

    2014-09-30

    We report an in situ measurement of the electric field attenuation length at radio frequencies for the bulk ice at Summit Station, Greenland, made by broadcasting radio-frequency signals vertically through the ice and measuring the relative power in the return ground bounce signal. We find the depth-averaged field attenuation length to be 947 +92/-85 meters at 75 MHz. While this measurement has clear radioglaciological applications, the radio clarity of the ice also has implications for the detection of ultra-high energy (UHE) astrophysical particles via their radio emission in dielectric media such as ice. The measured attenuation length at Summit Station is comparable to previously measured radio-frequency attenuation lengths at candidate particle detector sites around the world, and strengthens the case for Summit Station as the most promising northern site for UHE neutrino detection.

  1. An in situ measurement of the radio-frequency attenuation in ice at Summit Station, Greenland

    E-Print Network [OSTI]

    J. Avva; J. M. Kovac; C. Miki; D. Saltzberg; A. G. Vieregg

    2015-12-02

    We report an in situ measurement of the electric field attenuation length at radio frequencies for the bulk ice at Summit Station, Greenland, made by broadcasting radio-frequency signals vertically through the ice and measuring the relative power in the return ground bounce signal. We find the depth-averaged field attenuation length to be 947 +92/-85 meters at 75 MHz. While this measurement has clear radioglaciological applications, the radio clarity of the ice also has implications for the detection of ultra-high energy (UHE) astrophysical particles via their radio emission in dielectric media such as ice. Assuming a reliable extrapolation to higher frequencies, the measured attenuation length at Summit Station is comparable to previously measured radio-frequency attenuation lengths at candidate particle detector sites around the world, and strengthens the case for Summit Station as a promising northern site for UHE neutrino detection.

  2. Saltwell Leak Detector Station Programmable Logic Controller (PLC) Software Configuration Management Plan (SCMP)

    SciTech Connect (OSTI)

    WHITE, K.A.

    2000-11-28

    This document provides the procedures and guidelines necessary for computer software configuration management activities during the operation and maintenance phases of the Saltwell Leak Detector Stations as required by HNF-PRO-309, Rev. 1, Computer Software Quality Assurance, Section 2.4, Software Configuration Management. The software configuration management plan (SCMP) integrates technical and administrative controls to establish and maintain technical consistency among requirements, physical configuration, and documentation for the Saltwell Leak Detector Station Programmable Logic Controller (PLC) software during the Hanford application, operations and maintenance. This SCMP establishes the Saltwell Leak Detector Station PLC Software Baseline, status changes to that baseline, and ensures that software meets design and operational requirements and is tested in accordance with their design basis.

  3. Control system for, and a method of, heating an operator station of a work machine

    DOE Patents [OSTI]

    Baker, Thomas M.; Hoff, Brian D.; Akasam, Sivaprasad

    2005-04-05

    There are situations in which an operator remains in an operator station of a work machine when an engine of the work machine is inactive. The present invention includes a control system for, and a method of, heating the operator station when the engine is inactive. A heating system of the work machine includes an electrically-powered coolant pump, a power source, and at least one piece of warmed machinery. An operator heat controller is moveable between a first and a second position, and is operable to connect the electrically-powered coolant pump to the power source when the engine is inactive and the operator heat controller is in the first position. Thus, by deactivating the engine and then moving the operator heat controller to the first position, the operator may supply electrical energy to the electrically-powered coolant pump, which is operably coupled to heat the operator station.

  4. Modeling and Simulation of the Longitudinal Beam Dynamics - RF Station Interaction in the LHC Rings

    SciTech Connect (OSTI)

    Mastorides, T; Rivetta, C.; Fox, J.D.; Winkle, D.Van; /SLAC; Baudrenghien, P.; Tuckmantel, J.; /CERN

    2008-07-07

    A non-linear time-domain simulation has been developed to study the interaction between longitudinal beam dynamics and RF stations in the LHC rings. The motivation for this tool is to determine optimal LLRF configurations, to study system sensitivity on various parameters, and to define the operational and technology limits. It will be also used to study the effect of RF station noise, impedance, and perturbations on the beam life time and longitudinal emittance. It allows the study of alternative LLRF implementations and control algorithms. The insight and experience gained from our PEP-II simulation is important for this work. In this paper we discuss properties of the simulation tool that will be helpful in analyzing the LHC RF system and its initial results. Partial verification of the model with data taken during the LHC RF station commissioning is presented.

  5. Utility perspective on station blackout rule implementation with NUMARC 87-00

    SciTech Connect (OSTI)

    Maracek, J.

    1990-01-01

    The development of the station blackout rule involved an unusually high level of cooperation between the industry and the Nuclear Regulatory Commission (NRC). The industry developed an approach to implementation of the rule in the form of the Nuclear Management and Resources Council's (NUMARC's) Guidelines and Technical Bases for NUMARC Initiatives Addressing Station Blackout at Light Water Reactors (NUMARC 87-00). This document was reviewed and accepted by the NRC staff as a means for meeting the requirements of the station blackout rule. Yet difficulties still arose when individual utilities used the NUMARC 87-00 approach to respond to the rule. This presentation examines the development process and subsequent difficulties and identifies potential improvements for development and implementation of new rules in the future.

  6. The IQ-wall and IQ-station -- harnessing our collective intelligence to realize the potential of ultra-resolution and immersive visualization

    SciTech Connect (OSTI)

    Eric A. Wernert; William R. Sherman; Chris Eller; David Reagan; Patrick D. Beard; Eric T. Whiting; Patrick O'Leary

    2012-03-01

    We present a pair of open-recipe, affordably-priced, easy-to-integrate, and easy-to-use visualization systems. The IQ-wall is an ultra-resolution tiled display wall that scales up to 24 screens with a single PC. The IQ-station is a semi-immersive display system that utilizes commodity stereoscopic displays, lower cost tracking systems, and touch overlays. These systems have been designed to support a wide range of research, education, creative activities, and information presentations. They were designed to work equally well as stand-alone installations or as part of a larger distributed visualization ecosystem. We detail the hardware and software components of these systems, describe our deployments and experiences in a variety of research lab and university environments, and share our insights for effective support and community development.

  7. DESIGNING AND OPPORTUNITY FUEL WITH BIOMASS AND TIRE-DERIVED FUEL FOR COFIRING AT WILLOW ISLAND GENERATING STATION AND COFIRING SAWDUST WITH COAL AT ALBRIGHT GENERATING STATION

    SciTech Connect (OSTI)

    K. Payette; D. Tillman

    2004-06-01

    During the period July 1, 2000-March 31, 2004, Allegheny Energy Supply Co., LLC (Allegheny) conducted an extensive demonstration of woody biomass cofiring at its Willow Island and Albright Generating Stations. This demonstration, cofunded by USDOE and Allegheny, and supported by the Biomass Interest Group (BIG) of EPRI, evaluated the impacts of sawdust cofiring in both cyclone boilers and tangentially-fired pulverized coal boilers. The cofiring in the cyclone boiler--Willow Island Generating Station Unit No.2--evaluated the impacts of sawdust alone, and sawdust blended with tire-derived fuel. The biomass was blended with the coal on its way to the combustion system. The cofiring in the pulverized coal boiler--Albright Generating Station--evaluated the impact of cofiring on emissions of oxides of nitrogen (NO{sub x}) when the sawdust was injected separately into the furnace. The demonstration of woody biomass cofiring involved design, construction, and testing at each site. The results addressed impacts associated with operational issues--capacity, efficiency, and operability--as well as formation and control of airborne emissions such as NO{sub x}, sulfur dioxide (SO{sub 2}2), opacity, and mercury. The results of this extensive program are detailed in this report.

  8. Next Generation Hydrogen Station Composite Data Products: Data through Quarter 4 of 2014; NREL (National Renewable Energy Laboratory)

    SciTech Connect (OSTI)

    Sprik, S.; Kurtz, J.; Ainscough, C.; Peters, M.

    2015-05-14

    This publication includes 43 composite data products (CDPs) produced for next generation hydrogen stations, with data through the fourth quarter of 2014.

  9. An Intelligent Solar Powered Battery Buffered EV Charging Station with Solar Electricity Forecasting and EV Charging Load Projection Functions

    E-Print Network [OSTI]

    Zhao, Hengbing; Burke, Andrew

    2014-01-01

    power source from inherent intermittent solar PV power.B. Solar PV Electricity Forecasting Fig. 1. Charging stationForecasting Power Output of Solar Photovoltaic System Using

  10. Cost of Adding E85 Fueling Capability to Existing Gasoline Stations: NREL Survey and Literature Search (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-03-01

    Fact sheet provides framework for gas station owners to access what a reasonable cost would be to install E85 infrastructure.

  11. Device to facilitate moving an electrical cable of an electric vehicle charging station and method of providing the same

    DOE Patents [OSTI]

    Karner, Donald B

    2014-04-29

    Some embodiments include a device to facilitate moving an electrical cable of an electric vehicle charging station. Other embodiments of related systems and methods are also disclosed.

  12. Installation of River and Drain Instrumentation Stations to Monitor Flow and Water Quality and Internet Data Sharing 

    E-Print Network [OSTI]

    Sheng, Z.; Brown, C.; Creel, B.; Srinivasan, R.; Michelsen, A.; Fahy, M. P.

    2008-01-01

    IMS, data sharing and transfer, user needs assessment, Rio Grande, Rio Grande Project, gage station, surface water flow, groundwater, downloadable Microsoft Access database....

  13. Perspective on occupational radiation exposures at a hypothetical fusion power station

    SciTech Connect (OSTI)

    Easterly, C.E.; Cannon, J.B.

    1983-01-01

    If current technology were used, several major sources of potential occupational radiation exposure at fusion power stations would be quite similar to those at current light water reactor power stations. Based upon this similarity, crude estimates of doses received from various maintenance operations at fusion power reactors are made. The dose estimates reinforce the need for concurrent development of sophisticated remote maintenance devices and low-activation materials for fusion reactors. It is concluded that minimization of occupational doses can be best achieved by developing an overall maintenance strategy that combines the best features of remote techniques and low activation materials as opposed to developing one or the other exclusively.

  14. The response of BWR Mark II containments to station blackout severe accident sequences

    SciTech Connect (OSTI)

    Greene, S.R.; Hodge, S.A.; Hyman, C.R.; Tobias, M.L. (Oak Ridge National Lab., TN (USA))

    1991-05-01

    This report describes the results of a series of calculations conducted to investigate the response of BWR Mark 2 containments to short-term and long-term station blackout severe accident sequences. The BWR-LTAS, BWRSAR, and MELCOR codes were employed to conduct quantitative accident sequence progression and containment response analyses for several station blackout scenarios. The accident mitigation effectiveness of automatic depressurization system actuation, drywell flooding via containment spray operation, and debris quenching in Mark 2 suppression pools is assessed. 27 refs., 16 figs., 21 tabs.

  15. Stratigraphic Profiles for Selected Hanford Site Seismometer Stations and Other Locations

    SciTech Connect (OSTI)

    Last, George V.

    2014-02-01

    Stratigraphic profiles were constructed for eight selected Hanford Site seismometer stations, five Hanford Site facility reference locations, and seven regional three-component broadband seismometer stations. These profiles provide interpretations of the subsurface layers to support estimation of ground motions from past earthquakes, and the prediction of ground motions from future earthquakes. In most cases these profiles terminated at the top of the Wanapum Basalt, but at selected sites profiles were extended down to the top of the crystalline basement. The composite one-dimensional stratigraphic profiles were based primarily on previous interpretations from nearby boreholes, and in many cases the nearest deep borehole is located kilometers away.

  16. Design of a photovoltaic central power station: flat-plate array

    SciTech Connect (OSTI)

    Not Available

    1984-02-01

    A design for a photovoltaic central power station using fixed flat-panel arrays has been developed. The 100 MW plant is assumed to be located adjacent to the Saguaro Power Station of Arizona Public Service. The design assumes high-efficiency photovoltaic modules using dendritic web cells. The modules are arranged in 5 MW subfields, each with its own power conditioning unit. The photovoltaic output is connected to the existing 115 kV utility switchyard. The site specific design allows detailed cost estimates for engineering, site preparation, and installation. Collector and power conditioning costs have been treated parametrically.

  17. http://www.sord.nv.doe.gov/meda_wind_roses_by_station_numbe.htm

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefield Municipal GasAdministration Medal01 Sandia4)9 FederalRivers andMEDA Station Wind Roses STATION

  18. SINGLE HEATER TEST FINAL REPORT

    SciTech Connect (OSTI)

    J.B. Cho

    1999-05-01

    The Single Heater Test is the first of the in-situ thermal tests conducted by the U.S. Department of Energy as part of its program of characterizing Yucca Mountain in Nevada as the potential site for a proposed deep geologic repository for the disposal of spent nuclear fuel and high-level nuclear waste. The Site Characterization Plan (DOE 1988) contained an extensive plan of in-situ thermal tests aimed at understanding specific aspects of the response of the local rock-mass around the potential repository to the heat from the radioactive decay of the emplaced waste. With the refocusing of the Site Characterization Plan by the ''Civilian Radioactive Waste Management Program Plan'' (DOE 1994), a consolidated thermal testing program emerged by 1995 as documented in the reports ''In-Situ Thermal Testing Program Strategy'' (DOE 1995) and ''Updated In-Situ Thermal Testing Program Strategy'' (CRWMS M&O 1997a). The concept of the Single Heater Test took shape in the summer of 1995 and detailed planning and design of the test started with the beginning fiscal year 1996. The overall objective of the Single Heater Test was to gain an understanding of the coupled thermal, mechanical, hydrological, and chemical processes that are anticipated to occur in the local rock-mass in the potential repository as a result of heat from radioactive decay of the emplaced waste. This included making a priori predictions of the test results using existing models and subsequently refining or modifying the models, on the basis of comparative and interpretive analyses of the measurements and predictions. A second, no less important, objective was to try out, in a full-scale field setting, the various instruments and equipment to be employed in the future on a much larger, more complex, thermal test of longer duration, such as the Drift Scale Test. This ''shake down'' or trial aspect of the Single Heater Test applied not just to the hardware, but also to the teamwork and cooperation between multiple organizations performing their part in the test.

  19. Photon tunnelling microscopy of polyethylene single crystals

    E-Print Network [OSTI]

    Srinivasarao, Mohan

    Photon tunnelling microscopy of polyethylene single crystals Mohan Srinivasarao* and Richard S:photon tunnellingmicroscopy;single crystals; polyethylene) INTRODUCTION The study of morphology of polymers is an area

  20. U.S.DOE Global Monthly Station Temperature and Precipitation, 1738-1980

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    The global monthly station temperature and precipitation data from the U.S. Department of Energy, a dataset hosted at, covers the time period from January, 1738 to December, 1980. The air temperature and precipitation levels are platform observations from ground and water surfaces. The data are maintained in the Research Data Archive at the National Center for Atmospheric Research.

  1. Rate Adaptation and Base Station Reconfiguration for Battery Efficient Video Download

    E-Print Network [OSTI]

    Dey, Sujit

    dynamically depending on battery and buffer levels of the mobile device, the channel conditions experienced conditions so as to avoid stalling, and do not consider the effect of video download on mobile device batteryRate Adaptation and Base Station Reconfiguration for Battery Efficient Video Download Ranjini

  2. Lambda Station: On-demand flow based routing for data intensive Grid applications over multitopology networks

    SciTech Connect (OSTI)

    Bobyshev, A.; Crawford, M.; DeMar, P.; Grigaliunas, V.; Grigoriev, M.; Moibenko, A.; Petravick, D.; Rechenmacher, R.; Newman, H.; Bunn, J.; Van Lingen, F.; Nae, D.; Ravot, S.; Steenberg, C.; Su, X.; Thomas, M.; Xia, Y.; /Caltech

    2006-08-01

    Lambda Station is an ongoing project of Fermi National Accelerator Laboratory and the California Institute of Technology. The goal of this project is to design, develop and deploy network services for path selection, admission control and flow based forwarding of traffic among data-intensive Grid applications such as are used in High Energy Physics and other communities. Lambda Station deals with the last-mile problem in local area networks, connecting production clusters through a rich array of wide area networks. Selective forwarding of traffic is controlled dynamically at the demand of applications. This paper introduces the motivation of this project, design principles and current status. Integration of Lambda Station client API with the essential Grid middleware such as the dCache/SRM Storage Resource Manager is also described. Finally, the results of applying Lambda Station services to development and production clusters at Fermilab and Caltech over advanced networks such as DOE's UltraScience Net and NSF's UltraLight is covered.

  3. The Alpha Magnetic Spectrometer (AMS): search for antimatter and dark matter on the International Space Station

    E-Print Network [OSTI]

    R. Battiston

    1997-08-27

    The AMS is a state of the art detector for extraterrestrial study of antimatter, matter and missing matter. After a precursor flight on STS91 in May 1998, AMS will be installed on the International Space Station where it will operate for three years. In this paper the AMS experiment is described and is physics potential reviewed.

  4. Cosmic-Ray Studies with an Alpha Magnetic Spectrometer (AMS Detector) on the International Space Station

    SciTech Connect (OSTI)

    Plyaskin, V.V. [Institute of Theoretical and Experimental Physics, Bol'shaya Cheremushkinskaya ul. 25, Moscow, 117259 (Russian Federation)

    2005-01-01

    A brief description of the physics research program implemented with an alpha magnetic spectrometer (AMS detector) by a large-scale international collaboration on board the International Space Station is presented. The features of the experimental facility under construction are given, along with some results obtained during the test flight of the prototype spectrometer on board a space shuttle.

  5. THE AMS-02 TRANSITION RADIATION DETECTOR FOR THE INTERNATIONAL SPACE STATION

    E-Print Network [OSTI]

    Roma "La Sapienza", Università di

    The Alpha Magnetic Spectrometer (AMS-02) is a large experiment in the International Space Station (ISS is presented 1. Introduction The Alpha Magnetic Spectrometer is an experiment which will be mounted composite/aluminum honeycomb octagonal support, fixed by an M-structure to the AMS-02 magnet flange. A space

  6. The status and prospective of environmental radiation monitoring stations in Saudi Arabia

    SciTech Connect (OSTI)

    Al-Kheliewi, Abdullah S.; Holzheimer, Clous

    2014-09-30

    The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS’s) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS’s. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS)

  7. Station-keeping Analysis for the Terrestrial Planet Formation in Halo Orbit

    E-Print Network [OSTI]

    Born, George

    nd Sun-Earth Libration Point OD Orbit Determination SKM Station-keeping Maneuver t0 A given initial: An Earth drift-away orbit, and a halo orbit about the second Sun-Earth libration point, EL2. This paper geometrically in a plane: four collectors evenly spaced in a line and one combiner offset perpendicularly from

  8. Webinar: Overview of Station Analysis Tools Developed in Support of H2USA

    Broader source: Energy.gov [DOE]

    This webinar will provide a basic introduction to the Hydrogen Refueling Stations Analysis Model (HRSAM) and the Hydrogen Financial Analysis Scenario Tool (H2FAST), developed by Argonne National Laboratory and the National Renewable Energy Laboratory, respectively, to address key technical and financial barriers to hydrogen fueling infrastructure deployment.

  9. Invariant Manifolds for the Station Keeping of Solar Sails Ariadna Farres, AJ

    E-Print Network [OSTI]

    Boyer, Edmond

    Invariant Manifolds for the Station Keeping of Solar Sails Ariadna Farr´es, AJ Universitat de 2 / 45 inria-00585612,version1-14Apr2011 #12;Background What is a Solar Sail ? Solar Sails are a new concept of spacecraft propulsion that takes ad- vantage of the Solar radiation pressure to propel

  10. STANFORD AMATEUR RADIO STATION W6YX PRESS RELEASE June 19, 2008

    E-Print Network [OSTI]

    Straight, Aaron

    Relay League (ARRL, www.arrl.org), the national association for Amateur Radio (a.k.a. "ham radio was designed to test operators' abilities to set up and operate portable stations under emergency conditions, fire, the Red Cross, and other agencies." Field Day is a serious test of skill, but it is also

  11. STATION KEEPING CLOSE TO UNSTABLE EQUILIBRIUM POINTS WITH A SOLAR SAIL

    E-Print Network [OSTI]

    Barcelona, Universitat de

    AAS 07-347 STATION KEEPING CLOSE TO UNSTABLE EQUILIBRIUM POINTS WITH A SOLAR SAIL Ariadna Farr´es and `Angel Jorba We have considered the movement of a solar sail in the Sun - Earth system. Using the Circular RTBP adding the solar radiation pressure as a model we have a 2D family of equilibrium points

  12. A dynamical systems approach for the station keeping of a Solar Sail

    E-Print Network [OSTI]

    Barcelona, Universitat de

    A dynamical systems approach for the station keeping of a Solar Sail Ariadna Farr´es and `Angel considered the movement of a solar sail in the Sun - Earth system. As a model we have used the RTBP adding the solar radiation pressure. It can be seen that we have a 2D family of equilibria parametrised by the two

  13. DEVELOPMENT OF A NATURAL GAS TO HYDROGEN FUEL STATION William E. Liss

    E-Print Network [OSTI]

    for compressed natural gas vehicles. The integrated natural gas-to-hydrogen system includes a high efficiency on leveraging of developments in the stationary PEM fuel cell and compressed natural gas vehicle market sectorsDEVELOPMENT OF A NATURAL GAS TO HYDROGEN FUEL STATION William E. Liss P: 847-768-0753; E: william

  14. SPATIAL VARIABILITY OF SNOW DEPTH MEASUREMENTS AT TWO MOUNTAIN PASS SNOW TELEMETRY STATIONS

    E-Print Network [OSTI]

    Anderson, Charles W.

    THESIS SPATIAL VARIABILITY OF SNOW DEPTH MEASUREMENTS AT TWO MOUNTAIN PASS SNOW SPATIAL VARIABILITY OF SNOW DEPTH MEASUREMENTS AT TWO MOUNTAIN PASS SNOW TELEMETRY STATIONS Much of the Western United States relies heavily on spring snow melt runoff to meet its industrial, agricultural

  15. Solar Radiation Monitoring Station (SoRMS): Humboldt State University, Arcata, California (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Wilcox, S.; Andreas, A.

    A partnership with HSU and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location.

  16. Modeling and Control of Flexible HEV Charging Station upgraded with Flywheel Energy Storage

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    1 Modeling and Control of Flexible HEV Charging Station upgraded with Flywheel Energy Storage reserves. A power balancing strategy based on a local energy storage system (ESS) is proposed in this paper], [8]. The aim of this paper is to address the problem by intro- ducing a dedicated energy storage

  17. Short-term irradiance variability: Preliminary estimation of station pair correlation as a function of distance

    E-Print Network [OSTI]

    Review Short-term irradiance variability: Preliminary estimation of station pair correlation the irradiance variability observed at two neighboring sites as a function of their distance of the considered time scale. Ó 2012 Elsevier Ltd. All rights reserved. Keywords: Irradiance; Variability; High

  18. PacificSouthwestResearchStationPrograms Air Pollution and Global Change

    E-Print Network [OSTI]

    PacificSouthwestResearchStationPrograms Air Pollution and Global Change Impacts on Western Forest branch of the USDA Forest Service in the states of California and Hawaii and the U.S.-affiliat- ed economy in the world) and Hawaii (a strategic location in the Pacific Rim economies and tourism). We

  19. PacificSouthwestResearchStationPrograms Air Pollution and Global Change

    E-Print Network [OSTI]

    PacificSouthwestResearchStationPrograms Air Pollution and Global Change Impacts on Western Forest of the USDA Forest Service in the states of California and Hawaii and the U.S.-affiliat- ed Pacific Islands in the world) and Hawaii (a strategic location in the Pacific Rim economies and tourism). We develop

  20. EIS-0080: Decommissioning of the Shippingport Atomic Power Station, Hanford Site, Richland, Washington

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy's Remedial Actions Program Office developed this statement to assess the impacts of decommissioning the Shippingport Atomic Power Station as well as analyze possible decommissioning alternatives, evaluate potential environmental impacts associated with each alternative, and present cost estimates for each alternative.

  1. Assessing the viability of level III electric vehicle rapid-charging stations

    E-Print Network [OSTI]

    Gogoana, Radu

    2010-01-01

    This is an analysis of the feasibility of electric vehicle rapid-charging stations at power levels above 300 kW. Electric vehicle rapid-charging (reaching above 80% state-of-charge in less than 15 minutes) has been ...

  2. Natural Gas Compressor Stations on the Interstate Pipeline Network: Developments Since 1996

    Reports and Publications (EIA)

    2007-01-01

    This special report looks at the use of natural gas pipeline compressor stations on the interstate natural gas pipeline network that serves the lower 48 states. It examines the compression facilities added over the past 10 years and how the expansions have supported pipeline capacity growth intended to meet the increasing demand for natural gas.

  3. Asian emissions of CO and NOx: Constraints from aircraft and Chinese station data

    E-Print Network [OSTI]

    Palmer, Paul

    Asian emissions of CO and NOx: Constraints from aircraft and Chinese station data Yuxuan X. Wang to constrain estimates of Asian emissions of CO and NOx. A priori emissions are based on a detailed bottom emissions of CO and NOx, respectively, distributed heterogeneously, with the largest adjustments required

  4. Laser-free inter-networking hybrid base stations towards convergence of wireless

    E-Print Network [OSTI]

    Bakaul, Masuduzzaman

    direction, the uplink electrical signals from wireless and wired customers are electrically combinedLaser-free inter-networking hybrid base stations towards convergence of wireless and wired access with an optical network unit for overlaying the transport of wireless signals in an optical access network

  5. Solar Radiation Monitoring Station (SoRMS): Humboldt State University, Arcata, California (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Wilcox, S.; Andreas, A.

    2007-05-02

    A partnership with HSU and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location.

  6. INHERENT WATER OPTICAL PROPERTIES AT THE CARIBBEAN TIME SERIES STATION (CaTS)

    E-Print Network [OSTI]

    Gilbes, Fernando

    INHERENT WATER OPTICAL PROPERTIES AT THE CARIBBEAN TIME SERIES STATION (CaTS) Fernando Gilbes Rico 00681 ABSTRACT The temporal variability of the inherent water optical properties at the Caribbean wavelengths, but in all cases, the values were less than one. The correlation between bio-optical properties

  7. Call Completion Probability in Heterogeneous Networks with Energy Harvesting Base Stations

    E-Print Network [OSTI]

    Durrani, Salman

    energy consumption model and using tools from stochastic geometry, we derive very tight upper and lower. INTRODUCTION Base stations that can harvest renewable energy sources, such as solar and wind, are being% of which are powered by solar energy [1] and Nokia-Siemens has built `green' (i.e., renewable energy

  8. Seismic tomography of Taiwan: Improved constraints from a dense network of strong motion stations

    E-Print Network [OSTI]

    Wu, Yih-Min

    Seismic tomography of Taiwan: Improved constraints from a dense network of strong motion stations. [1] In this study, a large collection of 41,141 S-P times from the untapped records of the Taiwan from the Taiwan Central Weather Bureau Seismic Network (CWBSN) to image the Vp and Vp/Vs structures

  9. SCDAP severe core-damage studies: BWR ATWS and PWR station blackout

    SciTech Connect (OSTI)

    Laats, E.T.; Chambers, R.; Driskell, W.E.

    1983-01-01

    The Severe Accident Sequence Analysis (SASA) Program, sponsored by the US Nuclear Regulatory Commission (NRC), is addressing a number of accident scenarios that potentially pose a health hazard to the public. Two of the scenarios being analyzed in detail at the Idaho National Engineering Laboratory (INEL) are the station blackout at the Bellefonte nuclear plant and the anticipated transient without scram (ATWS) at the Browns Ferry-1 plant. The INEL analyses of the station blackout and ATWS have been divided into four parts, which represent the sequence being followed in this study. First, the evaluation of long term irradiation effects prior to the station blackout or ATWS was conducted using the FRAPCON-2 fuel rod behavior code; second, the reactor primary and secondary coolant system behavior is being analyzed with the RELAP5 code; third, the degradation of the core is being analyzed with the SCDAP code; and finally, the containment building response is being analyzed with the CONTEMPT code. This paper addresses only the SCDAP/MODO degraded core analyses for both the station blackout and ATWS scenarios.

  10. EMERGENCY PROCEDURES * Activate the nearest fire alarm pull station and call

    E-Print Network [OSTI]

    Arnold, Elizabeth A.

    EMERGENCY PROCEDURES FIRE * Activate the nearest fire alarm pull station and call 568 a fire alarm is activated, even if there are no obvious signs of an emergency! * DO NOT use the elevator by emergency personnel and respond to location designated by your building coordinator outside the structure

  11. Malm Hydrogen and CNG/Hydrogen filling station and Hythane bus project

    E-Print Network [OSTI]

    Malmö Hydrogen and CNG/Hydrogen filling station and Hythane bus project Bengt Ridell Carl Bro and the Municipality of Malmö started a long- term co-operation regarding conversion from diesel to CNG on the city busses. Now in the region Skåne more than 330 buses, 80 trucks and about 1000 cars are running on CNG

  12. The effects of solar-geomagnetically induced currents on electrical systems in nuclear power stations

    SciTech Connect (OSTI)

    Subudhi, M. [Brookhaven National Lab., Upton, NY (United States)] [Brookhaven National Lab., Upton, NY (United States); Carroll, D.P. [Florida Univ., Gainesville, FL (United States)] [Florida Univ., Gainesville, FL (United States); Kasturi, S. [MOS, Inc., Melville, NY (United States)] [MOS, Inc., Melville, NY (United States)

    1994-01-01

    This report presents the results of a study to evaluate the potential effects of geomagnetically induced currents (GICs) caused by the solar disturbances on the in-plant electrical distribution system and equipment in nuclear power stations. The plant-specific electrical distribution system for a typical nuclear plant is modeled using the ElectroMagnetic Transient Program (EMTP). The computer model simulates online equipment and loads from the station transformer in the switchyard of the power station to the safety-buses at 120 volts to which all electronic devices are connected for plant monitoring. The analytical model of the plant`s electrical distribution system is studied to identify the transient effects caused by the half-cycle saturation of the station transformers due to GIC. This study provides results of the voltage harmonics levels that have been noted at various electrical buses inside the plant. The emergency circuits appear to be more susceptible to high harmonics due to the normally light load conditions. In addition to steady-state analysis, this model was further analyzed simulating various plant transient conditions (e.g., loss of load or large motor start-up) occurring during GIC events. Detail models of the plant`s protective relaying system employed in bus transfer application were included in this model to study the effects of the harmonic distortion of the voltage input. Potential harmonic effects on the uniterruptable power system (UPS) are qualitatively discussed as well.

  13. Sei Vojany Station repowering reconstruction assessment feasibility study. Volume 2. Export trade information

    SciTech Connect (OSTI)

    Not Available

    1992-01-01

    Six technologies are considered for application to the proposed Vojany Power Station EVO III. These technologies are: Conventional pulverized coal (PC) with SOx and NOx control; Atmospheric circulating fluidized bed (CFB); Atmospheric bubbling fluidized bed (BFB); Pressurized fluidized bed combustion combined cycle (PFBC-CC); Integrated coal gasification combined cycle (IGCC); and Gas fired combustion turbine combined cycle (CTCC).

  14. Guide for Identifying and Converting High-Potential Petroleum Brownfield Sites to Alternative Fuel Stations

    SciTech Connect (OSTI)

    Johnson, C.; Hettinger, D.; Mosey, G.

    2011-05-01

    Former gasoline stations that are now classified as brownfields can be good sites to sell alternative fuels because they are in locations that are convenient to vehicles and they may be seeking a new source of income. However, their success as alternative fueling stations is highly dependent on location-specific criteria. First, this report outlines what these criteria are, how to prioritize them, and then applies that assessment framework to five of the most popular alternative fuels--electricity, natural gas, hydrogen, ethanol, and biodiesel. The second part of this report delves into the criteria and tools used to assess an alternative fuel retail site at the local level. It does this through two case studies of converting former gasoline stations in the Seattle-Eugene area into electric charge stations. The third part of this report addresses steps to be taken after the specific site has been selected. This includes choosing and installing the recharging equipment, which includes steps to take in the permitting process and key players to include.

  15. Symposium in Honor of Dr. Richard Arnowitt Texas A&M, College Station, Texas

    E-Print Network [OSTI]

    Allen, Roland E.

    Symposium in Honor of Dr. Richard Arnowitt Texas A&M, College Station, Texas September 19, Texas A&M University 9:30 a.m. ­ 10:15 a.m. A OneWorld formulation of quantum mechanics Charles Pran Nath, Northeastern University 11:00 a.m. ­ 11:30 a.m. Break Chair: Wolfgang Schleich, Texas A

  16. RELAP5/MOD3 simulation of the station blackout experiment conducted at the IIST facility

    SciTech Connect (OSTI)

    Ferng, Y.M.; Liu, T.J.; Lee, C.H. [Inst. of Nuclear Energy Research, Lung-Tan (Taiwan, Province of China)

    1996-10-01

    Thermal-hydraulic responses in the station blackout experiment conducted at the IIST facility are simulated through the use of the advanced system code RELAP5/MOD3. Typical behaviors occurring in the IIST station blackout transient are characterized by secondary boiloff, primary saturation and pressurization, and subsequent core uncovery and heatup. As the coolant inventory within the steam generator secondary system boils dry, the primary system pressure increases as a result of degradation of the heat removal ability of the steam generator secondary side. This pressurization phenomenon causes the pressurizer safety valve to open and the primary coolant to deplete through the valve, causing the core to eventually become uncovered. The same response can be exactly simulated by the current model. The current calculated results show fairly good agreement with the experimental data, but the timing of the events occurring in the station blackout transient is calculated earlier than the measured value. The overall comparison of key parameters between the calculated results and IIST test data, however, reveals that the current RELAP5/MOD3 model can provide reasonable station blackout modeling for simulating long-term system behavior.

  17. Seventh annual report of the Texas Agricultural Experiment Station for the year 1894. 

    E-Print Network [OSTI]

    Connell, J. H.; Harrington, H. H.; Francis, M.; Price, R. H.; Adriance, Duncan; Clayton, James

    1895-01-01

    . ............................................... J. H. CONNELL, M. SC Director. ......................................... H. H. HARRINGTON, M. SC.. Chemist. ......................................... M. FRANCIS, D. V. 3f ..Veterinarian. .......................................... R. H. PRICE, B... submitted, M. FRANCIS, Veterinar ian. REPORT OF THE HORTICULTURIST. 1 COLTXGE STATION, TEXAS, January 12, 1895. J. H. Connell, Directo: : DEAR SIR-In accordance with your request, I present herewith the report of the Department of Horticulture...

  18. Wind Climate Analyses for National Weather Service Stations in the Southeast

    SciTech Connect (OSTI)

    Weber, A.H.

    2003-02-10

    Wind speed and direction data have been collected by National Weather Service (NWS) Stations in the U.S. for a number of years and presented in various forms to help depict the climate for different regions. The Savannah River Technology Center (SRTC) is particularly interested in the Southeast since mesoscale models using NWS wind observations are run on a daily basis for emergency response and other operational purposes at the Savannah River Site (SRS). Historically, wind roses have been a convenient method to depict the predominant wind speeds and directions at measurement sites. Some typical applications of wind rose data are for climate and risk assessment; air pollution exposure and dose calculations; siting industrial plants, wind turbine generators, businesses, and homes; city planning; and air stagnation and high ozone concentration studies. The purpose of this paper is to demonstrate the overall relationships of wind patterns for NWS stations in the Southeast. Since organized collection of wind data records in the NWS developed rapidly in conjunction with the expansion of commercial aviation after World War II there are now about 50 years of wind speed and direction data available for a large number of NWS stations in this area. In this study we used wind roses for relatively short time scales to show the progression of winds diurnally and monthly to span a typical year. The date used here consist of wind records from 13 National Weather Service Stations in the Southeastern U.S. for approximately 50-year periods.

  19. Institute of Industrial Science, The University of Tokyo Chiba Experiment Station

    E-Print Network [OSTI]

    Tokyo, University of

    years some 30 laboratories have been engaged in approximately 60 projects at the Station. Outline Experimental Intersection Geothermal HVAC System Laboratory 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 experimental facilities such as model domes, geothermal air- conditioning system employing a ground heat

  20. IV. STATION CONFIGURATION AND SENSOR COMPARISONS Comparison of solar radiation data gathered at

    E-Print Network [OSTI]

    Oregon, University of

    8 IV. STATION CONFIGURATION AND SENSOR COMPARISONS Comparison of solar radiation data gathered of the instruments used to monitor the incident solar radiation. Five types of so- lar sensors and several different data loggers have been used to gather the solar radiation data presented in this data book

  1. Nanoscale Calorimetry of Isolated Polyethylene Single Crystals

    E-Print Network [OSTI]

    Allen, Leslie H.

    Nanoscale Calorimetry of Isolated Polyethylene Single Crystals A. T. KWAN, M. YU. EFREMOV, E. A-film differential scanning calorimetry to investigate the melt- ing of isolated polyethylene single crystals of lamellar single crystals of polyethylene (PE). We obtain thickness, diffraction, and calorimetry data

  2. Supplementary Figures Figure S1. Ambient seismic noise levels in dB relative to velocity power at two stations,

    E-Print Network [OSTI]

    Jackson, Jennifer M.

    Supplementary Figures Figure S1. Ambient seismic noise levels in dB relative to velocity power at two stations, HFN3 and BFN1, (Figure 1B). Both stations have three components (East, North, Vertical; or ENZ) but different types of instruments (EP, HH). The drop in power at frequencies less than 2 Hz

  3. BEAM-POWER DEPOSITION IN A 4-MW TARGET STATION FOR A MUON COLLIDER OR A NEUTRINO FACTORY

    E-Print Network [OSTI]

    McDonald, Kirk

    BEAM-POWER DEPOSITION IN A 4-MW TARGET STATION FOR A MUON COLLIDER OR A NEUTRINO FACTORY N of simulated power deposition in a y-z (vertical) section of the target station is shown in Fig. 2, and some, Coventry CV4 7AL, UK Abstract We present the results of power deposition in various components

  4. Thermal Modeling of NUHOMS HSM-15 and HSM-1 Storage Modules at Calvert Cliffs Nuclear Power Station ISFSI

    SciTech Connect (OSTI)

    Suffield, Sarah R.; Fort, James A.; Adkins, Harold E.; Cuta, Judith M.; Collins, Brian A.; Siciliano, Edward R.

    2012-10-01

    As part of the Used Fuel Disposition Campaign of the Department of Energy (DOE), visual inspections and temperature measurements were performed on two storage modules in the Calvert Cliffs Nuclear Power Station’s Independent Spent Fuel Storage Installation (ISFSI). Detailed thermal models models were developed to obtain realistic temperature predictions for actual storage systems, in contrast to conservative and bounding design basis calculations.

  5. Proceedings of Student/Faculty Research Day, CSIS, Pace University, May 7th, 2004 Pace University Weather Station Website

    E-Print Network [OSTI]

    Tappert, Charles

    people with minimal web browser experience can use to its fullest capacity. Any student from any school purchased and installed a Davis Vantage Pro Wireless Weather Station. It is housed at the Pace Environmental, barometer, temperature, solar incidence) is received at the base station and some calculations are performed

  6. Seasonal and diurnal dependence of Pc 3-5 magnetic pulsation power at geomagnetically conjugate stations in the auroral zones

    SciTech Connect (OSTI)

    Saito, Hiroaki (Univ. of Electro-Communications, Tokyo (Japan) National Institute of Polar Research, Tokyo (Japan)); Sato, Natsuo (National Institute of Polar Research, Tokyo (Japan)); Tonegawa, Yutaka (Tokai Univ., Hiratsuka (Japan)); Yoshino, Takeo (Univ. of Electro-Communications, Tokyo (Japan)); Saemundsson, T. (Univ. of Iceland, Reykjavik (Iceland))

    1989-06-01

    Seasonal and diurnal variations of Pc 3-5 magnetic pulsation powers have been examined using 2 years of magnetic data from geomagnetically conjugate stations, Syowa in Antarctica and Husafell and Tjoernes in Iceland. The magnetic pulsation powers are found to be relatively higher at the winter hemisphere station than at the summer station. The pulsations observed during equinox show a diurnal dependence, i.e., that the power density is higher in the geomagnetic morning at the stations in Iceland than at Syowa, and this relationship is reversed in the afternoon. The power density ratio of Pc 3 pulsations between the conjugate stations, which is associated with the seasons and with local time, is higher than that of Pc 5. These characteristics can be attributed to the effects of sunlight in the ionosphere, i.e., Pc 3-5 pulsations are shielded when the waves propagate from the magnetosphere to the ground through the sunlit ionosphere.

  7. Applications of the RELAP5 code to the station blackout transients at the Browns Ferry Unit One Plant

    SciTech Connect (OSTI)

    Schultz, R.R.; Wagoner, S.R.

    1983-01-01

    As a part of the charter of the Severe Accident Sequence Analysis (SASA) Program, station blackout transients have been analyzed using a RELAP5 model of the Browns Ferry Unit 1 Plant. The task was conducted as a partial fulfillment of the needs of the US Nuclear Regulatory Commission in examining the Unresolved Safety Issue A-44: Station Blackout (1) the station blackout transients were examined (a) to define the equipment needed to maintain a well cooled core, (b) to determine when core uncovery would occur given equipment failure, and (c) to characterize the behavior of the vessel thermal-hydraulics during the station blackout transients (in part as the plant operator would see it). These items are discussed in the paper. Conclusions and observations specific to the station blackout are presented.

  8. Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

    SciTech Connect (OSTI)

    John Pavlish; Jeffrey Thompson; Christopher Martin; Mark Musich; Lucinda Hamre

    2009-01-07

    The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During the time that enhanced AC was injected, the average mercury removal for the month long test was approximately 74% across the test baghouse module. ACI was interrupted frequently during the month long test because the test baghouse module was bypassed frequently to relieve differential pressure. The high air-to-cloth ratio of operations at this unit results in significant differential pressure, and thus there was little operating margin before encountering differential pressure limits, especially at high loads. This limited the use of sorbent injection as the added material contributes to the overall differential pressure. This finding limits sustainable injection of AC without appropriate modifications to the plant or its operations. Handling and storage issues were observed for the TOXECON ash-AC mixture. Malfunctioning equipment led to baghouse dust hopper plugging, and storage of the stagnant material at flue gas temperatures resulted in self-heating and ignition of the AC in the ash. In the hoppers that worked properly, no such problems were reported. Economics of mercury control at Big Brown were estimated for as-tested scenarios and scenarios incorporating changes to allow sustainable operation. This project was funded under the U.S. Department of Energy National Energy Technology Laboratory project entitled 'Large-Scale Mercury Control Technology Field Testing Program--Phase II'.

  9. Comparison of MELCOR modeling techniques and effects of vessel water injection on a low-pressure, short-term, station blackout at the Grand Gulf Nuclear Station

    SciTech Connect (OSTI)

    Carbajo, J.J.

    1995-06-01

    A fully qualified, best-estimate MELCOR deck has been prepared for the Grand Gulf Nuclear Station and has been run using MELCOR 1.8.3 (1.8 PN) for a low-pressure, short-term, station blackout severe accident. The same severe accident sequence has been run with the same MELCOR version for the same plant using the deck prepared during the NUREG-1150 study. A third run was also completed with the best-estimate deck but without the Lower Plenum Debris Bed (BH) Package to model the lower plenum. The results from the three runs have been compared, and substantial differences have been found. The timing of important events is shorter, and the calculated source terms are in most cases larger for the NUREG-1150 deck results. However, some of the source terms calculated by the NUREG-1150 deck are not conservative when compared to the best-estimate deck results. These results identified some deficiencies in the NUREG-1150 model of the Grand Gulf Nuclear Station. Injection recovery sequences have also been simulated by injecting water into the vessel after core relocation started. This marks the first use of the new BH Package of MELCOR to investigate the effects of water addition to a lower plenum debris bed. The calculated results indicate that vessel failure can be prevented by injecting water at a sufficiently early stage. No pressure spikes in the vessel were predicted during the water injection. The MELCOR code has proven to be a useful tool for severe accident management strategies.

  10. Ion crystal transducer for strong coupling between single ions and single photons

    E-Print Network [OSTI]

    L. Lamata; D. R. Leibrandt; I. L. Chuang; J. I. Cirac; M. D. Lukin; V. Vuletic; S. F. Yelin

    2011-07-11

    A new approach for realization of a quantum interface between single photons and single ions in an ion crystal is proposed and analyzed. In our approach the coupling between a single photon and a single ion is enhanced via the collective degrees of freedom of the ion crystal. Applications including single-photon generation, a memory for a quantum repeater, and a deterministic photon-photon, photon-phonon, or photon-ion entangler are discussed.

  11. Fact #832: August 4, 2014 Over Half of the Refueling Stations in the U.S. and Canada Sell Diesel Fuel

    Broader source: Energy.gov [DOE]

    A 2014 survey of over 110,000 refueling stations in the U.S. and Canada shows that over half of all refueling stations sell diesel fuel. The survey results are shown for five different regions of...

  12. Single-Chain Antibody Library

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Baird, Cheryl

    Researchers at Pacific Northwest National Laboratory (PNNL) have constructed a nonimmune library consisting of 109 human antibody scFv fragments, which have been cloned and expressed on the surface of yeast. Nanomolar-affinity scFvs are routinely obtained by magnetic bead screening and flow cytometric sorting. The yeast library can be amplified 1010 fold without measurable loss of clonal diversity. This allows for indefinite expansion of the library. All scFv clones can be assessed directly on the yeast cell surface by immunofluorescent labeling and flow cytometry, obviating separate subcloning, expression, and purification steps. The ability to use multiplex library screening demonstrates the utility of this approach for high-throughput antibody isolation for proteomic applications. The yeast library may be used for research projects or teaching performed for U.S. Government purposes only. If you would like to request an aliquot of the single-chain antibody library for your research, please print and fill out the Materials Transfer Agreement (MTA) [PDF, 20K]. The website provides the contact information for mailing the MTA. [copied from http://www.sysbio.org/dataresources/singlechain.stm

  13. Bent Diamond Crystals and Multilayer Based Optics at the new 5-Station Protein Crystallography Beamline 'Cassiopeia' at MAX-lab

    SciTech Connect (OSTI)

    Mammen, Christian B.; Als-Nielsen, Jens; Ursby, Thomas; Thunnissen, Marjolein

    2004-05-12

    A new 5-station beamline for protein crystallography is being commissioned at the Swedish synchrotron light source MAX-II at Lund University. Of the 2K/{gamma} = 14 mrad horizontal wiggler fan, the central 2 mrad are used and split in three parts. The central 1 mrad will be used for a station optimized for MAD experiments and on each side of the central fan, from 0.5 mrad to 1 mrad, there are two fixed energy stations using different energies of the same part of the beam. These, in total five stations, can be used simultaneously and independently for diffraction data collection. The two upstream monochromators for the side stations are meridionally bent asymmetric diamond(111) crystals in Laue transmission geometry. The monochromators for the downstream side stations are bent Ge(111) crystals in asymmetric Bragg reflection geometry. Curved multilayer mirrors inserted in the monochromatic beams provide focusing in the vertical plane. The first side station is under commissioning, and a preliminary test protein data set has been collected.

  14. Characterization of Single Barrier Microrefrigerators at Cryogenic Temperatures

    E-Print Network [OSTI]

    2009-01-01

    at Springerlink.com Characterization of Single Barriercooling) at 100 K. Characterization of Single BarrierThe experimental characterization of single barrier

  15. Qualitative Risk Assessment for an LNG Refueling Station and Review of Relevant Safety Issues

    SciTech Connect (OSTI)

    Siu, N.; Herring, J.S.; Cadwallader, L.; Reece, W.; Byers, J.

    1998-02-01

    This report is a qualitative assessment of the public and worker risk involved with the operation of a liquefied natural gas (LNG) vehicle refueling facility. This study includes facility maintenance and operations, tank truck deliveries, and end-use vehicle fueling; it does not treat the risks of LNG vehicles on roadways. Accident initiating events are identified by using a Master Logic Diagram, a Failure Modes and Effects Analysis, and historical operating experiences. The event trees were drawn to depict possible sequences of mitigating events following the initiating events. The phenomenology of LNG and other vehicle fuels is discussed to characterize the hazard posed by LNG usage. Based on the risk modeling and analysis, recommendations are given to improve the safety of LNG refueling stations in the areas of procedures and training, station design, and the dissemination of ``best practice`` information throughout the LNG community.

  16. Interim qualitative risk assessment for an LNG refueling station and review of relevant safety issues

    SciTech Connect (OSTI)

    Siu, N.; Herring, S.; Cadwallader, L.; Reece, W.; Byers, J.

    1997-07-01

    This report is a qualitative assessment of the public and worker risk involved with the operation of a liquefied natural (LNG) vehicle refueling facility. This study includes facility maintenance and operations, tanker truck delivers and end-use vehicle fueling; it does not treat the risks of LNG vehicles on roadways. Accident initiating events are identified by using a Master Logic Diagram, a Failure Modes and Effects analysis and historical operating experiences. The event trees were drawn to depict possible sequences of mitigating events following the initiating events. The phenomenology of LNG and other vehicle fuels is discussed to characterize the hazard posed by LNG usage. Based on the risk modeling and analysis, recommendations are given to improve the safety of LNG refueling stations in the areas of procedures and training, station design, and the dissemination of best practice information throughout the LNG community.

  17. Evaluation of sensors for NGV and fueling station applications. Topical report, November 1994-January 1996

    SciTech Connect (OSTI)

    Huebler, J.E.; Blazek, C.F.

    1996-05-01

    The commercial success of the Natural Gas Vehicles (NGV) requires the availability of sensors to make critical measurements, such as mass flow, gas composition, temperature, pressure, moisture, density, engine load, strain, etc. Engine, engine control, compressor, and dispenser manufacturers and fueling station packagers were surveyed to determine sensor use and needs. Their general comments on needed sensor improvements, detailed sensor specifications, and sensor priorities are given. Exhaust oxygen, mass flow, and gas composition were identified as the sensors of most concern. Because they deal with issues unique to NGV technology, evaluation of sensor technologies was limited to gas composition sensors. Sensor of principal concern for this application included: (1) on-board, in-line, feed forward devices and (2) fueling station monitors. Through an extensive survey, a baseline of information on gas composition sensors and emerging technologies for the NGV community was developed.

  18. Heat flows and energetic behavior of a telecommunication radio base station

    E-Print Network [OSTI]

    Petraglia, Antonio; Vetromile, Carmela; D'Onofrio, Antonio; Lubritto, Carmine

    2015-01-01

    This paper shows a study on energetic consumption of BTSs (Base Transceiver Stations) for mobile communication, related to conditioning functions. An energetic "thermal model" of a telecommunication station is proposed and studied. The results have been validated with a BTS in central Italy, showing good agreement. Findings show a substantial high internal-external temperature difference in the containing shelter, particularly during daytime and warm months, due to sources of heat (equipment, external temperature and sun radiation) and to the difficulty in spread the warmth out. The necessity to keep the operating temperatures within a given range for the correct functioning of the electronic equipment requires the use of conditioning setups, and this significantly increases the energetic demand of the whole system. The analysis of thermal flows across the shelter can help to gather further data on its temperature behavior and to devise practical measures to lower the power demand, while keeping the operating...

  19. Establishment of a Background Environmental Monitoring Station for the PNNL Campus

    SciTech Connect (OSTI)

    Fritz, Brad G.; Snyder, Sandra F.; Barnett, J. M.; Bisping, Lynn E.; Rishel, Jeremy P.

    2014-12-18

    The environmental surveillance of background levels of radionuclides and, in particular, the siting of a background environmental surveillance (monitoring) station are examined. Many published works identify and stress the need for background monitoring; however, little definitive and comprehensive information for siting a station exists. A definition of an ideal background monitoring location and the generic criteria recommended for use in establishing such a background monitoring location are proposed. There are seven primary (mandatory) criteria described with two additional, optional criteria. The criteria are applied to the Richland, Washington (WA), Pacific Northwest National Laboratory (PNNL) Campus, which currently uses background monitoring data from the nearby Hanford Site. Eleven potential background monitoring sites were identified, with one location in Benton City, WA found to meet all of the mandatory and optional criteria. It is expected that the new sampler will be installed and operating by the end of June, 2015.

  20. Development of criteria used to establish a background environmental monitoring station

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Fritz, Brad G.; Barnett, J. Matthew; Snyder, Sandra F.; Bisping, Lynn E.; Rishel, Jeremy P.

    2015-03-02

    It is generally considered necessary to measure concentrations of contaminants-of-concern at a background location when conducting atmospheric environmental surveillance. This is because it is recognized that measurements of background concentrations can enhance interpretation of environmental monitoring data. Despite the recognized need for background measurements, there is little published guidance available that describes how to identify an appropriate atmospheric background monitoring location. This paper develops generic criteria that can guide the decision making process for identifying suitable locations for background atmospheric monitoring station. Detailed methods for evaluating some of these criteria are also provided and a case study for establishment ofmore »an atmospheric background surveillance station as part of an environmental surveillance program is described. While the case study focuses on monitoring for radionuclides, the approach is equally valid for any airborne constituent being monitored. The case study shows that implementation of the developed criteria can result in a good, defensible choice for a background atmospheric monitoring location.« less

  1. Nuclear and in-source laser spectroscopy with the ISAC yield station

    SciTech Connect (OSTI)

    Kunz, Peter Bricault, Pierre; Dombsky, Marik; Lassen, Jens; Teigelhöfer, Andrea; Heggen, Henning; Andreoiu, Corina; Wong, Fiona

    2014-05-15

    A new decay station has been built for the ISAC facility at TRIUMF for the rapid and reliable characterization of radioactive ion beam (RIB) compositions and intensities with the capability of simultaneously collecting ?, ?, and ? decay data from RIB with intensities between a few and ?10{sup 11} ions per second. It features user-friendly control, data acquisition, and analysis software. The analysis of individual decay time structures allows the unambiguous assignment of ? and ? lines even with substantial isobaric contamination present. The capability for accurate half-life measurements is demonstrated with the example of {sup 46}K. The coupling of the yield station to the laser ion source, TRILIS, allows the correlation of radiometric data with automated laser frequency scans. First results of in-source laser spectroscopy measurements on astatine are discussed.

  2. Meteorological data for water years 1988-94 from five weather stations at Yucca Mountain, Nevada

    SciTech Connect (OSTI)

    Flint, A.L.; Davies, W.J.

    1997-11-01

    This report describes meteorological data collected from five weather stations at Yucca Mountain, Nevada, from as early as April 1987 through September 1994. The measurements include solar radiation, temperature, relative humidity, wind speed, wind vector magnitude, wind direction, wind vector direction, barometric pressure, and precipitation. Measurements were made very 10 seconds and averaged every 15 minutes. The data were collected as part of the geologic and hydrologic site-characterization studies of Yucca Mountain, a potential repository for high-level radioactive waste. Precipitation at the site ranged from a low of 12 millimeters total for water year 1989 to a high of 312 millimeters total for water year 1993. Air temperature ranged from a low of 15.1 degrees Celsius in December 1990 (water year 1991) to a high of 41.9 degrees Celsius in July 1989 (water year 1989). The weather station network also provides information on the spatial variability of precipitation and temperature.

  3. Report of Beeville Station (Number 4) Cabbage -- Fertilixers, Varieties, Shipping, Cauliflower -- Varities, Shipping. 

    E-Print Network [OSTI]

    Pittuck, B. C; McHenry, S. A.

    1900-01-01

    . - c 2d 3% .>a QG " gs 5 8 -? 1.75 1.70 1.59 2.83 3.49 3.31 3.38 3.45 3.53 3.81 ES i.$s e,.$ acs 0 C j cL v; %k- dsi % 107 133 133 144 154 154 153 155 155 15.1 w, : - F4 9 g ' 3 - 13618 13726 12819 23491...TEXAS AGR!-CULTU~LC%S~RI.M~ENT STATIONS. BULLETIN NO. 57. REPORT OF BEEVILLE STATION (NUMBER 4.) 1 CABBAGE-Fertilizers, Varieties, S hipping, CAULIFLOWER-Varieties, Shipping. I LC' FROTSCHER'S SUPERIQR LARG1 LATE FLAT DUTCH. f POSTOBBICE...

  4. Optical Precursor of a Single Photon

    SciTech Connect (OSTI)

    Zhang Shanchao; Chen, J. F.; Liu, Chang; Loy, M. M. T.; Wong, G. K. L.; Du, Shengwang [Department of Physics, Hong Kong University of Science and Technology, Clear Water Bay, Kowloon (Hong Kong)

    2011-06-17

    We report the direct observation of optical precursors of heralded single photons with step- and square-modulated wave packets passing through cold atoms. Using electromagnetically induced transparency and the slow-light effect, we separate the single-photon precursor, which always travels at the speed of light in vacuum, from its delayed main wave packet. In the two-level superluminal medium, our result suggests that the causality holds for a single photon.

  5. IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, VOL. 44, NO. 3, PAGES 638--644, AUGUST 1995 1 Integrated Power Control and Base Station

    E-Print Network [OSTI]

    Yates, Roy

    Power Control and Base Station Assignment Roy D. Yates and Ching­Yao Huang Abstract--- In cellular integrate power control and base station assignment. In the context of a CDMA system, we consider mobile. This minimization occurs over the set of power vectors and base station assignments. We show

  6. Natural radiation in fly ashes from coal thermal power stations in Spain

    SciTech Connect (OSTI)

    Baro, J.; Sanchez-Reyes, A.; Chinchon, J.S.; Lopez-Soler, A.; Vazquez, E.; Yague, A.

    1988-01-01

    Specific activity in samples of fly ashes from Spanish coal thermal power stations at Abono (Asturias), Andorra (Teruel), Alcudia (Mallorca) and Cercs (Barcelona) was analysed by gamma ray spectrometry. The values obtained permit us to quantify the presence of different natural radionuclides from /sup 232/Th, /sup 238/U, /sup 235/U series and /sup 40/K. The models are defined on the basis of these data to calculate the dosimetric impact caused by the use of fly ashes in the concrete.

  7. Biology and control of thrips attacking cotton in the vicinity of College Station, Texas 

    E-Print Network [OSTI]

    Pfrimmer, Theodore Roscoe

    1953-01-01

    Advisor) May 1953 BIOLOGY AND CONTROL OF THRIE3 ATTACKING COTTON IK THE VICINITY OF COLIEGE STATION, TEXAS By THEODORE ROSCCE P iE M fR t \\ \\ A Dissertation Submitted, to the Graduate School of the Agricultural and Mechanical College of Texas... cages during 1950 . . . . . . . . . 69 3. Comparison of the dosage-mortality curves for the toxicities of several compounds, applied as dusts, against Frankliniella tritici and F. exigua in large cages during 1950 ............................ 70 4...

  8. The effects of the Cedar Bayou Electric Generating Station on phytoplankton in adjacent waters 

    E-Print Network [OSTI]

    Smith, Jay Montgomery

    1983-01-01

    . ~pa e 1 Sampling, Hydrology, and Sample Treatment. Chlorophyll a Concentrati. ons Primary Productivity . Bioassay Studies 9 11 12 ~ ~ 13 RESULTS, 15 Temperature. Salinity . Chlorophyll a Concentrations Primary Productivity Bioassay... Studies DISCUSSION CONCLUSION REFERENCES APPENDIX 15 15 ~ ? 21 27 33 57 70 71 75 125 LIST OF TABLES Table Page 1 Surface water temperature ranges and means at sample stations from February 1978 through June 1979 . 17 2 Surface water...

  9. SPECKLE INTERFEROMETRY AT THE USNO FLAGSTAFF STATION: OBSERVATIONS OBTAINED IN 2008 AND NINE NEW ORBITS

    SciTech Connect (OSTI)

    Hartkopf, William I.; Mason, Brian D. E-mail: bdm@usno.navy.mil

    2011-08-15

    Results are presented for 299 speckle interferometric observations of double stars, obtained in 2008 at the USNO Flagstaff Station using the 1.55 m Kaj Strand Astrometric Reflector. Separations range from 0.''15 to 9.''88, with a median of 2.''22. This observing run concentrated on neglected systems, as well as systems in need of improved orbital elements; new orbital solutions have been determined for nine systems as a result.

  10. Functional Description of PIC16F877A Functions and Interfaces to GBT RFI Monitor Station

    E-Print Network [OSTI]

    Groppi, Christopher

    Functional Description of PIC16F877A Functions and Interfaces to GBT RFI Monitor Station. Detailed descriptions of the PIC16C877A can be found in two product references: "PIC16H878XA Data Sheet device on the www.microchip.com web site or as pic16F877.pdf and midrange mcu ref.pdf files in my project

  11. On the station keeping of a Solar sail in the Elliptic Sun-Earth system

    E-Print Network [OSTI]

    Barcelona, Universitat de

    On the station keeping of a Solar sail in the Elliptic Sun-Earth system Ariadna Farr´es and `Angel on the dynamics of a Solar sail in the Sun- Earth Elliptic Restricted Three-Body Problem with Solar radiation that the sail is perpendicular to the Sun-sail line, we find an equilibrium point in the Earth-Sun line closer

  12. MELCOR calculations for a low-pressure short-term station blackout in a BWR-6

    SciTech Connect (OSTI)

    Carbajo, J.J. [Martin Marietta Energy Systems, Oak Ridge, TN (United States)

    1995-12-31

    A postulated, low-pressure, short term station blackout severe accident has been analyzed using the MELCOR code for the Grand Gulf nuclear power plant. Different versions have been used with three different models of the plant. This paper presents results of the effects of different plant models and versions of MELCOR on the calculated results and to present the best-estimating timing of events for this transient.

  13. MHK ISDB/Instruments/Automatic Weather Station AWS 2700 | Open Energy

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History View NewTexas:Montezuma, Arizona:Oregon:LowellMHKInformation Automatic Weather Station AWS 2700

  14. H2FIRST Reference Station Design Task: Project Deliverable 2-2

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12,ExecutiveFinancing Programs |Reference Station Design Task Project Deliverable

  15. H2FIRST Reference Station Design Task: Stand-Alone Piping and Instrumentation Diagrams

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12,ExecutiveFinancing Programs |Reference Station Design Task Project

  16. Press Pass - Press Release - Single top quark

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Higgs." Discovering the single top quark production presents challenges similar to the Higgs boson search in the need to extract an extremely small signal from a very large...

  17. Metagenomics, metatranscriptomics and single cell genomics reveal...

    Office of Scientific and Technical Information (OSTI)

    and single cell genomics reveal functional response of active Oceanospirillales to Gulf oil spill Citation Details In-Document Search Title: Metagenomics, metatranscriptomics and...

  18. Cape Canaveral Air Force Station integrated resource assessment. Volume 2, Baseline detail

    SciTech Connect (OSTI)

    Wahlstrom, R.R.; McMordie, K.L.; Parker, S.A.; King, D.A.; Sandusky, W.F.

    1993-12-01

    The US Air Force (USAF) has tasked the Pacific Northwest Laboratory (PNL), in support of the US Department of Energy (DOE) Federal Energy Management Program (FEMP), to assess energy use at Cape Canaveral Air Force Station (AFS). The information obtained from this assessment will be used in identifying energy resource opportunities to reduce overall energy consumption by the station. The primary focus of this report is to assess the current baseline energy consumption at Cape Canaveral AFS. It is A companion report to Volume 1, the Executive Summary, and Volume 3, the Resource Assessment. This assessment requires that information be obtained and characterized for buildings, utilities, energy sources, energy uses, and load profiles to be used to improve the current energy system on the station. The characteristics of electricity, diesel fuel, No. 2 fuel oil, and motor vehicle gasoline (MOGAS) are analyzed for on-base facilities. The assessment examines basic regional information used to determine energy-use intensity (EUI) values for Cape Canaveral AFS facilities by building, fuel type, and energy end use. It also provides a summary of electricity consumption from Florida Power and Light Company (FPL) metered data for 1985--1991. Load profile information obtained from FPL data is presented for the North, South, and Titan Substations for the four seasons of the year, including weekdays and weekends.

  19. Six- and three-hourly meteorological observations from 223 USSR stations

    SciTech Connect (OSTI)

    Razuvaev, V.N.; Apasova, E.B.; Martuganov, R.A.; Kaiser, D.P.

    1995-04-01

    This document describes a database containing 6- and 3-hourly meteorological observations from a 223-station network of the former Soviet Union. These data have been made available through cooperation between the two principal climate data centers of the United States and Russia: the National Climatic Data Center (NCDC), in Asheville, North Carolina, and the All-Russian Research Institute of Hydrometeorological Information -- World Data Centre (RIHMI-WDC) in Obninsk. Station records consist of 6- and 3-hourly observations of some 24 meteorological variables including temperature, weather type, precipitation amount, cloud amount and type, sea level pressure, relative humidity, and wind direction and speed. The 6-hourly observations extend from 1936 to 1965; the 3-hourly observations extend from 1966 through the mid-1980s (1983, 1984, 1985, or 1986; depending on the station). These data have undergone extensive quality assurance checks by RIHMI-WDC, NCDC, and the Carbon Dioxide Information Analysis Center (CDIAC). The database represents a wealth of meteorological information for a large and climatologically important portion of the earth`s land area, and should prove extremely useful for a wide variety of regional climate change studies. These data are available free of charge as a numeric data package (NDP) from CDIAC. The NDP consists of this document and 40 data files that are available via the Internet or on 8mm tape. The total size of the database is {approximately}2.6 gigabytes.

  20. Design and early development of a UAV terminal and a ground station for laser communications

    E-Print Network [OSTI]

    Carrasco-Casado, Alberto; Sanchez-Pena, Jose M

    2015-01-01

    A free-space laser communication system has been designed and partially developed as an alternative to standard RF links from UAV to ground stations. This project belongs to the SINTONIA program (acronym in Spanish for low environmental-impact unmanned systems), led by BR&TE (Boeing Research and Technology Europe) with the purpose of boosting Spanish UAV technology. A MEMS-based modulating retroreflector has been proposed as a communication terminal onboard the UAV, allowing both the laser transmitter and the acquisition, tracking and pointing subsystems to be eliminated. This results in an important reduction of power, size and weight, moving the burden to the ground station. In the ground station, the ATP subsystem is based on a GPS-aided two-axis gimbal for tracking and coarse pointing, and a fast steering mirror for fine pointing. A beacon-based system has been designed, taking advantage of the retroreflector optical principle, in order to determine the position of the UAV in real-time. The system man...

  1. Darlington tritium removal facility and station upgrading plant dynamic process simulation

    SciTech Connect (OSTI)

    Busigin, A. [NITEK USA, Inc., 6405 NW 77 PL, Parkland, FL 33067 (United States); Williams, G. I. D.; Wong, T. C. W.; Kulczynski, D.; Reid, A. [Ontario Power Generation Nuclear, Box 4000, Bowmanville, ON L1C 3Z8 (Canada)

    2008-07-15

    Ontario Power Generation Nuclear (OPGN) has a 4 x 880 MWe CANDU nuclear station at its Darlington Nuclear Div. located in Bowmanville. The station has been operating a Tritium Removal Facility (TRF) and a D{sub 2}O station Upgrading Plant (SUP) since 1989. Both facilities were designed with a Distributed Control System (DCS) and programmable logic controllers (PLC) for process control. This control system was replaced with a DCS only, in 1998. A dynamic plant simulator was developed for the Darlington TRF (DTRF) and the SUP, as part of the computer control system replacement. The simulator was used to test the new software, required to eliminate the PLCs. The simulator is now used for operator training and testing of process control software changes prior to field installation. Dynamic simulation will be essential for the ITER isotope separation system, where the process is more dynamic than the relatively steady-state DTRF process. This paper describes the development and application of the DTRF and SUP dynamic simulator, its benefits, architecture, and the operational experience with the simulator. (authors)

  2. Regulatory/backfit analysis for the resolution of Unresolved Safety Issue A-44, Station Blackout

    SciTech Connect (OSTI)

    Rubin, A.M.

    1988-06-01

    Station blackout is the complete loss of alternating current (ac) electric power to the essential and nonessential buses in a nuclear power plant; it results when both offsite power and the onsite emergency ac power systems are unavailable. Because many safety systems required for reactor core decay heat removal and containment heat removal depend on ac power, the consequences of a station blackout could be severe. Because of the concern about the frequency of loss of offsite power, the number of failures of emergency diesel generators, and the potentially severe consequences of a loss of all ac power, ''Station Blackout'' was designated as Unresolved Safety Issue (USI) A-44. This report presents the regulatory/backfit analysis for USI A-44. It includes (1) a summary of the issue, (2) the recommended technical resolution, (3) alternative resolutions considered by the Nuclear Regulatory Commission (NRC) staff, (4) an assessment of the benefits and costs of the recommended resolution, (5) the decision rationale, (6) the relationship between USI A-44 and other NRC programs and requirements, and (7) a backfit analysis demonstrating that the resolution of USI A-44 complies with the backfit rule (10 CFR 50.109).

  3. Regulatory analysis for the resolution of Unresolved Safety Issue A-44, Station Blackout. Draft report

    SciTech Connect (OSTI)

    Rubin, A.M.

    1986-01-01

    ''Station Blackout'' is the complete loss of alternating current (ac) electric power to the essential and nonessential buses in a nuclear power plant; it results when both offsite power and the onsite emergency ac power systems are unavailable. Because many safety systems required for reactor core decay heat removal and containment heat removal depend on ac power, the consequences of a station blackout could be severe. Because of the concern about the frequency of loss of offsite power, the number of failures of emergency diesel generators, and the potentially severe consequences of a loss of all ac power, ''Station Blackout'' was designated as Unresolved Safety Issue (USI) A-44. This report presents the regulatory analysis for USI A-44. It includes: (1) a summary of the issue, (2) the proposed technical resolution, (3) alternative resolutions considered by the Nuclear Regulatory Commission (NRC) staff, (4) an assessment of the benefits and costs of the recommended resolution, (5) the decision rationale, and (6) the relationship between USI A-44 and other NRC programs and requirements.

  4. VALIDATION OF MERCURY CEMS WHEN COFIRING BIOMASS AT MADISON ELECTRIC'S BLOUNT STATION

    SciTech Connect (OSTI)

    Dennis L. Laudal; Jeffrey S. Thompson

    2000-09-30

    The state of Wisconsin has been concerned about mercury deposition into its lakes and streams and has been evaluating strategies to reduce mercury emissions. As part of this effort, the Blount Station, owned and operated by Madison Gas and Electric Company (MGE), has undergone a project to evaluate the effects and potential mercury emissions reduction of cofiring preconsumer waste. MGE owns and operates the Blount Generating Station located in central Madison, Wisconsin. At present, Blount operates with nine boilers and six turbine generators. The two largest boilers at Blount produce 400,000 pounds of steam per hour at 950 F and 1250 psi. These larger boilers, MGE's Boiler Nos. 8 and 9, have the capability of cofiring both paper and plastic. MGE's Blount Generating Station was one of the first electric generating stations in the United States to retrofit its existing steam boilers to successfully burn refuse-derived fuel and other alternate fuels including waste paper and wood. It is the No. 9 boiler that was the focus of this project to determine the effect of cofiring PDF (plastic- and paper-derived fuel) on speciated mercury emissions. The project was laid out to compare four different fuel combinations: (1) coal feed only, (2) coal with plastic, (3) coal with paper, and (4) coal with paper and plastic. The design was to run the boiler for 2 days at each condition, thus allowing four samples to be taken at each condition. This plan was aimed at getting at least three representative samples at each condition and allowed for difficulties in sampling and boiler operation. The following objectives were accomplished as part of the project to determine the effects of cofiring PDF on mercury emissions and speciation at MGE Blount Station: Successfully completed all of the mercury sampling for each of the four boiler/PDF conditions using the Ontario Hydro (OH) mercury speciation method; Determined mercury concentrations at the stack location using mercury continuous emission monitors (CEMs) for each of the four boiler/PDF conditions; Calculated the overall mercury mass balance for each of the runs; Determined chlorine concentrations at the stack location using EPA Method 26A for each of the four boiler/PDF conditions; and Calculated speciated mercury flow to determine removal and/or transformations before its exiting the unit at the stack for each of the four boiler/PDF conditions.

  5. Radio Astronomy Data Model for Single-Dish Multiple-Feed Telescopes, and Robledo Archive Architecture

    E-Print Network [OSTI]

    Santander-Vela, J D; Gómez, J F; Verdes-Montenegro, L; Leon, S; Gutíerrez, R; Rodrigo, C; Morata, O; Solano, E; Suárez, O

    2008-01-01

    All the effort that the astrophysical community has put into the development of the Virtual Observatory (VO) has surpassed the non-return point: the VO is a reality today, and an initiative that will self-sustain, and to which all archival projects must adhere. We have started the design of the scientific archive for the DSS-63 70-m antenna at NASA's DSN station in Robledo de Chavela (Madrid). Here we show how we can use all VO proposed data models to build a VO-compliant single-dish, multiple-feed, radio astronomical archive data model (RADAMS) suitable for the archival needs of the antenna. We also propose an exhaustive list of Universal Content Descriptors (UCDs) and FITS keywords for all relevant metadata. We will further refine this data model with the experience that we will gain from that implementation.

  6. Radio Astronomy Data Model for Single-Dish Multiple-Feed Telescopes, and Robledo Archive Architecture

    E-Print Network [OSTI]

    J. D. Santander-Vela; E. Garcia; J. F. Gomez; L. Verdes-Montenegro; S. Leon; R. Gutierrez; C. Rodrigo; O. Morata; E. Solano; O. Suarez

    2008-10-02

    All the effort that the astrophysical community has put into the development of the Virtual Observatory (VO) has surpassed the non-return point: the VO is a reality today, and an initiative that will self-sustain, and to which all archival projects must adhere. We have started the design of the scientific archive for the DSS-63 70-m antenna at NASA's DSN station in Robledo de Chavela (Madrid). Here we show how we can use all VO proposed data models to build a VO-compliant single-dish, multiple-feed, radio astronomical archive data model (RADAMS) suitable for the archival needs of the antenna. We also propose an exhaustive list of Universal Content Descriptors (UCDs) and FITS keywords for all relevant metadata. We will further refine this data model with the experience that we will gain from that implementation.

  7. Banding in single crystals during plastic deformation

    E-Print Network [OSTI]

    Mahesh, Sivasambu

    Banding in single crystals during plastic deformation M. Arul Kumar a Sivasambu Mahesh a,b a. India. Abstract A rigid-plastic rate-independent crystal plasticity model capable of capturing band- ing such as dense dislocation walls. Key words: crystal plasticity, single crystal, macroscopic shear band, regular

  8. Computer Science BSc (Single Honours Degree)

    E-Print Network [OSTI]

    Brierley, Andrew

    72 Computer Science BSc (Single Honours Degree) Computer Science BSc (Joint Honours Degrees) Computer Science and one of: Economics Logic and Philosophy of Science Management Management Science MSci (Single Honours Degree) Computer Science Entry Requirements (see also pages 152-189) The likely grades

  9. Dissecting a Single-Use Film Camera

    E-Print Network [OSTI]

    Zanibbi, Richard

    Dissecting a Single- Use Film Camera RIT Center for Imaging Science #12;WARNING · The single use the BACK of the camera. Leave the front in place. · Remove the AA battery on the left side. You can use this battery in any electronic device that requires a AA battery. BATTERY FILM FILM CANNISTER VIEWFINDER FILM

  10. Ames Lab 101: Single Crystal Growth

    ScienceCinema (OSTI)

    Schlagel, Deborah

    2014-06-04

    Ames Laboratory scientist Deborah Schlagel talks about the Lab's research in growing single crystals of various metals and alloys. The single crystal samples are vital to researchers' understanding of the characteristics of a materials and what gives these materials their particular properties.

  11. State of Connecticut Single Audit Report

    E-Print Network [OSTI]

    Alpay, S. Pamir

    State of Connecticut Single Audit Report For the Fiscal Year Ended June 30, 2014 AUDITORS OF PUBLIC ACCOUNTS JOHN C. GERAGOSIAN ROBERT M. WARD #12;STATE OF CONNECTICUT Single Audit Report For the Year Ended ..................................................................................................1 State of Connecticut Financial Statements Independent Auditors' Report

  12. How to get to the Victory Room Cross the Bourke Street Pedestrian Bridge from Southern Cross Station until you reach

    E-Print Network [OSTI]

    Liley, David

    Cross Station until you reach Gate 2. Turn to your left, walk to Gate 9 and follow the signs. Take the lift to Level 1 and follow the signs to the Victory Room. By Taxi Direct the taxi to stop

  13. 2015 Hydrogen Student Design Contest Challenges Students to Develop Innovative Hydrogen Fueling Station Business and Financing Models

    Broader source: Energy.gov [DOE]

    The Hydrogen Education Foundation announced the 11th annual Hydrogen Student Design Contest, which will challenge student teams to develop business and financing models for hydrogen fueling stations. Registration for the Contest is open until January 16, 2015.

  14. Webinar November 18: An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project

    Broader source: Energy.gov [DOE]

    The Energy Department will present a live webinar entitled "An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project" on Tuesday, November 18, from 12:00 to 1:00 Eastern Standard Time (EST).

  15. Computer software design description for the Treated Effluent Disposal Facility (TEDF), Project L-045H, Operator Training Station (OTS)

    SciTech Connect (OSTI)

    Carter, R.L. Jr.

    1994-11-07

    The Treated Effluent Disposal Facility (TEDF) Operator Training Station (OTS) is a computer-based training tool designed to aid plant operations and engineering staff in familiarizing themselves with the TEDF Central Control System (CCS).

  16. CHOOSING A CHARGING STATION USING SOUND IN COLONY ROBOTICS GARY PARKER, CONNECTICUT COLLEGE, USA, PARKER@CONNCOLL.EDU

    E-Print Network [OSTI]

    Parker, Gary B.

    CHOOSING A CHARGING STATION USING SOUND IN COLONY ROBOTICS GARY PARKER, CONNECTICUT COLLEGE, USA, PARKER@CONNCOLL.EDU OZGUR IZMIRLI, CONNECTICUT COLLEGE, USA, OIZM@CONNCOLL.EDU ABSTRACT This research

  17. Single superpartner production at Tevatron Run II

    E-Print Network [OSTI]

    F. Deliot; G. Moreau; C. Royon

    2000-07-25

    We study the single productions of supersymmetric particles at Tevatron Run II which occur in the $2 \\to 2-body$ processes involving R-parity violating couplings of type $\\l'_{ijk} L_i Q_j D_k^c$. We focus on the single gaugino productions which receive contributions from the resonant slepton productions. We first calculate the amplitudes of the single gaugino productions. Then we perform analyses of the single gaugino productions based on the three charged leptons and like sign dilepton signatures. These analyses allow to probe supersymmetric particles masses beyond the present experimental limits, and many of the $\\l'_{ijk}$ coupling constants down to values smaller than the low-energy bounds. Finally, we show that the studies of the single gaugino productions offer the opportunity to reconstruct the $\\tilde \\chi^0_1$, $\\tilde \\chi^{\\pm}_1$, $\\tilde \

  18. The effect of weather and climate on traffic accidents, crime, and mortality in Bryan-College Station, Texas 

    E-Print Network [OSTI]

    Campbell, Timothy Richard

    1973-01-01

    THE EFFECT OF WEATHER AND CLIMATE ON TRAFFIC ACCIDENTS, CRIME, AND MORTALITY IN BRYAN-COLLEGE STATION, TEXAS A Thesis by TIMOTHY RICHARD CAMPBELL Submitted to the Graduate College of Texas A&M University in partial fulfillment... of the requirements for the degree of MASTER OF SCIENCE December 1973 Major Subject: Meteorology THE EFFECT OF HEATHER AND CLIMATE ON TRAFFIC ACCIDENTS, CRIME, AND MORTALITY IN BRYAN-COLLEGE STATION, TEXAS. A Thesis by TIMOTHY RICHARD CAMPBELL Approved...

  19. Reliability and optimization studies of nuclear and solar powered systems utilizing a Stirling engine for the space station 

    E-Print Network [OSTI]

    Schmitz, Paul Charles

    1990-01-01

    RELIABILITY AND OPTIMIZATION STUDIES OF NUCLEAR AND SOLAR POWERED SYSTEMS UTILIZING A STIRLING ENGINE FOR THE SPACE STATION A Thesis by PAUL CHARLES SCHMITZ Submitted to the Office of Graduate Studies of Texas A&M University in partial... fulfillment of the requirements for the degree of MASTER OF SCIENCE August 1990 Major Subject: Nuclear Engineering RELIABILITY AND OPTIMIZATION STUDIES OF NUCLEAR AND SOLAR POWERED SYSTEMS UTILIZING A STIRLING ENGINE FOR THE SPACE STATION A Thesis...

  20. Single atom as a macroscopic entanglement source 

    E-Print Network [OSTI]

    Zhou, Ling; Xiong, Han; Zubairy, M. Suhail.

    2006-01-01

    as a macroscopic entanglement source Ling Zhou,1,2 Han Xiong,1 and M. Suhail Zubairy1 1Institute for Quantum Studies and Department of Physics, Texas A&M University, College Station, Texas 77843-4242, USA 2Department of Physics, Dalian University... losses. DOI: 10.1103/PhysRevA.74.022321 PACS number?s?: 03.67.Mn, 42.50.Dv I. INTRODUCTION Quantum entanglement lies at the heart of quantum com- puting and quantum information science. Cavity quantum electrodynamics ?QED? provides an important...

  1. Assessment of Radio-Frequency Radiation Exposure Level from Selected Mobile Base Stations (MBS) in Lokoja, Kogi State, Nigeria

    E-Print Network [OSTI]

    Victor, U J Nwankwo; Dada, S S; Onugba, A A; Ushie, P

    2012-01-01

    The acquisition and use of mobile phone is tremendously increasing especially in developing countries, but not without a concern. The greater concern among the public is principally over the proximity of mobile base stations (MBS) to residential areas rather than the use of handsets. In this paper, we present an assessment of Radio-Frequency (RF) radiation exposure level measurements and analysis of radiation power density (in \\mu W/sq m) from mobile base stations relative to radial distance (in metre). The minimum average power density from individual base station in the town was about 47\\mu W/sq m while the average maximum was about 1.5mW/sq m. Our result showed that average power density of a base station decreases with increase in distance (from base station) and that radiation intensity varies from one base station to another even at the same distance away. Our result (obtained signature of power density variation) was also compared with the 'expected' signature. It was found that radiation from external...

  2. Fast recognition of single molecules based on single event photon statistics

    E-Print Network [OSTI]

    Shuangli Dong; Tao Huang; Yuan Liu; Jun Wang; Guofeng Zhang; Liantuan Xiao+; Suotang Jia

    2007-08-02

    Mandel Q-parameter, which is determined from single event photon statistics, provides an alternative to differentiate single-molecule with fluorescence detection. In this work, by using the Q-parameter of the sample fluorescence compared to that of an ideal double-molecule system with the same average photon number, we present a novel and fast approach for identifying single molecules based on single event photon statistics analyses, compared with commonly used two-time correlation measurements. The error estimates for critical values of photon statistics are also presented for single-molecule determination.

  3. Intrinsic chirp of single-cycle pulses

    SciTech Connect (OSTI)

    Lin Qiang; Zheng Jian [Institute of Optics, Department of Physics, Zhejiang University, Hangzhou 310027 (China); Dai Jianming; Ho, I-Chen; Zhang, X.-C. [Center for Terahertz Research, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States)

    2010-04-15

    The Fourier transform-limited electromagnetic pulse has been regarded to be free of chirps for a long time. This is no longer true if the pulse duration goes down to or less than one optical cycle. We report the experimental observation of intrinsic chirps in such pulses with the sub-single-cycle terahertz (THz) waveforms obtained with a standard THz time-domain spectroscopy system. The results confirm the break down of the carrier-envelope (CE) expression for single-cycle optical pulses, and may influence the experimental measurements and theoretical modeling with single-cycle pulses.

  4. Alpha Magnetic Spectrometer (AMS02) experiment on the International Space Station (ISS)

    E-Print Network [OSTI]

    Behcet Alpat

    2003-08-27

    The Alpha Magnetic Spectrometer experiment is realized in two phases. A precursor flight (STS-91) with a reduced experimental configuration (AMS01) has successfully flown on space shuttle Discovery in June 1998. The final version (AMS02) will be installed on the International Space Station (ISS) as an independent module in early 2006 for an operational period of three years. The main scientific objectives of AMS02 include the searches for the antimatter and dark matter in cosmic rays. In this work we will discuss the experimental details as well as the improved physics capabilities of AMS02 on ISS.

  5. The ARM Best Estimate Station-based Surface (ARMBESTNS) Data set

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Qi,Tang; Xie,Shaocheng

    The ARM Best Estimate Station-based Surface (ARMBESTNS) data set merges together key surface measurements from the Southern Great Plains (SGP) sites. It is a twin data product of the ARM Best Estimate 2-dimensional Gridded Surface (ARMBE2DGRID) data set. Unlike the 2DGRID data set, the STNS data are reported at the original site locations and show the original information, except for the interpolation over time. Therefore, users have the flexibility to process the data with the approach more suitable for their applications.

  6. NGV fueling station technology program: CNG dispenser development goals. Interim report, February-June 1994

    SciTech Connect (OSTI)

    Svedeman, S.J.; Buckingham, J.C.; Behring, K.A.; McKee, R.J.

    1994-09-01

    The objective of the project is to investigate improvements to the CNG dispensers used at fueling stations. CNG dispensers perform similar functions to gasoline dispensers in that they control the fuel flow, measure the amount of fuel dispensed into the vehicle, and compute the sale amount. The specific areas where improvements are required include: reducing the dispenser cost, improving the dispensed gas flow measurement accuracy, reducing the time required to fill the vehicle, and increasing the level of fill provided by the dispenser control system.

  7. The ARM Best Estimate Station-based Surface (ARMBESTNS) Data set

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Qi,Tang; Xie,Shaocheng

    2015-08-06

    The ARM Best Estimate Station-based Surface (ARMBESTNS) data set merges together key surface measurements from the Southern Great Plains (SGP) sites. It is a twin data product of the ARM Best Estimate 2-dimensional Gridded Surface (ARMBE2DGRID) data set. Unlike the 2DGRID data set, the STNS data are reported at the original site locations and show the original information, except for the interpolation over time. Therefore, users have the flexibility to process the data with the approach more suitable for their applications.

  8. Cirrus cloud-temperature interactions over a tropical station, Gadanki from lidar and satellite observations

    SciTech Connect (OSTI)

    S, Motty G, E-mail: mottygs@gmail.com; Satyanarayana, M., E-mail: mottygs@gmail.com; Krishnakumar, V., E-mail: mottygs@gmail.com; Dhaman, Reji k., E-mail: mottygs@gmail.com [Department of Optoelectronics, University of Kerala, Kariavattom, Trivandrum-695 581, Kerala (India)

    2014-10-15

    The cirrus clouds play an important role in the radiation budget of the earth's atmospheric system and are important to characterize their vertical structure and optical properties. LIDAR measurements are obtained from the tropical station Gadanki (13.5{sup 0} N, 79.2{sup 0} E), India, and meteorological indicators derived from Radiosonde data. Most of the cirrus clouds are observed near to the tropopause, which substantiates the strength of the tropical convective processes. The height and temperature dependencies of cloud height, optical depth, and depolarization ratio were investigated. Cirrus observations made using CALIPSO satellite are compared with lidar data for systematic statistical study of cirrus climatology.

  9. Irish Potatoes: Results of Experiments at Troupe Sub-station, Smith County. 

    E-Print Network [OSTI]

    Green, Edward C.

    1904-01-01

    considerably by rot, and had to replant. The absence of rot in the Station field was probably due to the previous treatment of the seed. The potatoes had been cut to two-eye pieces, sprinkled with fine air-slaked lime, and exposed to sun and air for several... days before planting. They were turned over each day and an occasional sifting of air-slaked lime given them. As a result of this treatment the cut surfaces were dry and well cured before planting. All plats were cultivated an equal number of times...

  10. Sandia National Laboratories land use permit for operations at Oliktok Alaska Long Range Radar Station.

    SciTech Connect (OSTI)

    Catechis, Christopher Spyros

    2013-02-01

    The property subject to this Environmental Baseline Survey (EBS) is located at the Oliktok Long Range Radar Station (LRRS). The Oliktok LRRS is located at 70%C2%B0 30' W latitude, 149%C2%B0 53' W longitude. It is situated at Oliktok Point on the shore of the Beaufort Sea, east of the Colville River. The purpose of this EBS is to document the nature, magnitude, and extent of any environmental contamination of the property; identify potential environmental contamination liabilities associated with the property; develop sufficient information to assess the health and safety risks; and ensure adequate protection for human health and the environment related to a specific property.

  11. Tampa Electric Company`s Polk Power Station Integrated Gasification Combined Cycle Project

    SciTech Connect (OSTI)

    Jenkins, S.D.; Shafer, J.R.

    1994-12-31

    Tampa Electric Company (TEC) is in the construction phase for the new Polk Power Station, Unit {number_sign}1. This will be the first unit at a new site and will use Integrated Gasification Combined Cycle (IGCC) technology for power generation. The unit will utilize oxygen-blown entrained-flow coal gasification, along with combined cycle technology, to provide nominal net 26OMW of generation. As part of the environmental features of this process, the sulfur species in the coal will be recovered as a commercial grade sulfuric acid by-product. The sulfur will be removed from the synthesis gas utilizing a cold gas clean-up system (CGCU).

  12. https://mi3.ncdc.noaa.gov/mi3report/MISC/asos-stations.txt

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefield Municipal GasAdministration Medal01 Sandia4)9 FederalRivers andMEDA Station WindSelect aNCDCID WBAN

  13. Single Amplifies Whole Genome Shotgun- Applications

    SciTech Connect (OSTI)

    Pelletier, Eric [Genoscope

    2010-06-04

    Eric Pelletier of Genoscope discusses new sequencing technology developments to study a single cell at a large scale on June 4, 2010 at the "Sequencing, Finishing, Analysis in the Future" meeting in Santa Fe, NM

  14. Asymmetric Architecture for Heralded Single Photon Sources

    E-Print Network [OSTI]

    Luca Mazzarella; Francesco Ticozzi; Alexander V. Sergienko; Giuseppe Vallone; Paolo Villoresi

    2013-02-15

    Single photon source represent a fundamental building block for optical implementations of quantum information tasks ranging from basic tests of quantum physics to quantum communication and high-resolution quantum measurement. In this paper we investigate the performance of a multiplexed system based on asymmetric configuration of multiple heralded single photon sources. {To compare the effectiveness of different designs we introduce a single-photon source performance index that is based on the value of single photon probability required to achieve a guaranteed signal to noise ratio.} The performance and scalability comparison with both currently existing multiple-source architectures and faint laser configurations reveals an advantage the proposed scheme offers in realistic scenarios. This analysis also provides insights on the potential of using such architectures for integrated implementation.

  15. Press Pass - Press Release - Single Top

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    DZero finds evidence of rare single top quark; Observation marks a step closer to finding Higgs boson Batavia, Ill.--Scientists of the DZero collaboration at the Department of...

  16. Light a Single Candle: Studying Supernovae

    E-Print Network [OSTI]

    O'Leary, Dianne P.

    Light a Single Candle: Studying Supernovae Dianne P. O'Leary Supernovae are exploding stars study, following a paper by Rust, O'Leary, and Mullen (2009), how well the acceleration hypothesis fits

  17. Spin effects in single-electron transistors

    E-Print Network [OSTI]

    Granger, Ghislain

    2005-01-01

    Basic electron transport phenomena observed in single-electron transistors (SETs) are introduced, such as Coulomb-blockade diamonds, inelastic cotunneling thresholds, the spin-1/2 Kondo effect, and Fano interference. With ...

  18. Single mode pulsed dye laser oscillator

    DOE Patents [OSTI]

    Hackel, Richard P. (Livermore, CA)

    1992-01-01

    A single mode pulsed dye laser oscillator is disclosed. The dye laser oscillator provides for improved power efficiency by reducing the physical dimensions of the overall laser cavity, which improves frequency selection capability.

  19. Singles correlation energy contributions in solids

    E-Print Network [OSTI]

    Klimeš, Ji?í; Maggio, Emanuele; Kresse, Georg

    2015-01-01

    The random phase approximation to the correlation energy often yields highly accurate results for condensed matter systems. However, ways how to improve its accuracy are being sought and here we explore the relevance of singles contributions for prototypical solid state systems. We set out with a derivation of the random phase approximation using the adiabatic connection and fluctuation dissipation theorem, but contrary to the most commonly used derivation, the density is allowed to vary along the coupling constant integral. This yields results closely paralleling standard perturbation theory. We re-derive the standard singles of G\\"orling-Levy perturbation theory [G\\"orling and Levy, Phys. Rev. A {\\bf 50}, 196 (1994)], highlight the analogy of our expression to the renormalized singles introduced by Ren and coworkers [Ren, Tkatchenko, Rinke, and Scheffler, Phys. Rev. Lett. {\\bf 106}, 153003 (2011)], and introduce a new approximation for the singles using the density matrix in the random phase approximation. ...

  20. North Shore Gas- Single Family Direct Install

    Broader source: Energy.gov [DOE]

    Owners of single-family homes, condos, townhomes and two-flats may be eligible for a free installation of new programmable thermostats, pipe insulation, showerheads, Compact Fluorescent Bulbs (CFLs...