Powered by Deep Web Technologies
Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Property:Nominal Voltage | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy ResourcesLoadingPenobscot County,ContAddr2 JumpNbrInjWells Jump to: navigation, search PropertyNominal

2

Flexible method for monitoring fuel cell voltage  

DOE Patents [OSTI]

A method for equalizing the measured voltage of each cluster in a fuel cell stack wherein at least one of the clusters has a different number of cells than the identical number of cells in the remaining clusters by creating a pseudo voltage for the different cell numbered cluster. The average cell voltage of the all of the cells in the fuel cell stack is calculated and multiplied by a constant equal to the difference in the number of cells in the identical cell clusters and the number of cells in the different numbered cell cluster. The resultant product is added to the actual voltage measured across the different numbered cell cluster to create a pseudo voltage which is equivalent in cell number to the number of cells in the other identical numbered cell clusters.

Mowery, Kenneth D. (Noblesville, IN); Ripley, Eugene V. (Russiaville, IN)

2002-01-01T23:59:59.000Z

3

Electronic circuit for measuring series connected electrochemical cell voltages  

DOE Patents [OSTI]

An electronic circuit for measuring voltage signals in an energy storage device is disclosed. The electronic circuit includes a plurality of energy storage cells forming the energy storage device. A voltage divider circuit is connected to at least one of the energy storage cells. A current regulating circuit is provided for regulating the current through the voltage divider circuit. A voltage measurement node is associated with the voltage divider circuit for producing a voltage signal which is proportional to the voltage across the energy storage cell.

Ashtiani, Cyrus N. (West Bloomfield, MI); Stuart, Thomas A. (Toledo, OH)

2000-01-01T23:59:59.000Z

4

Electrochemical Characterization of Voltage Fade in LMR-NMC cells...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electrochemical Characterization of Voltage Fade in LMR-NMC cells 2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer...

5

Modeling the operating voltage of liquid metal battery cells  

E-Print Network [OSTI]

A one-dimensional, integrative model of the voltage during liquid metal battery operation has been developed to enhance the understanding of performance at the cell level. Two liquid metal batteries were studied: Mg-Sb for ...

Newhouse, Jocelyn Marie

2014-01-01T23:59:59.000Z

6

Design & Fabrication of a High-Voltage Photovoltaic Cell  

SciTech Connect (OSTI)

Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

Felder, Jennifer; /North Carolina State U. /SLAC

2012-09-05T23:59:59.000Z

7

Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells  

DOE Patents [OSTI]

Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl[sub 2] and SO[sub 2]Cl[sub 2] electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl[sub 2] and Li/SO[sub 2]Cl[sub 2] batteries.

Delnick, F.M.

1993-04-13T23:59:59.000Z

8

Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells  

DOE Patents [OSTI]

Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl.sub.2 and SO.sub.2 Cl.sub.2 electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl.sub.2 and Li/SO.sub.2 Cl.sub.2 batteries.

Delnick, Frank M. (Albuquerque, NM)

1993-01-01T23:59:59.000Z

9

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided into high voltage  

E-Print Network [OSTI]

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided than one subtype of channel. A new subfamily of voltage-dependent calcium channel á1 subunit genes. 1999), having four domains, each with a voltage sensor and a pore-forming P loop. However

Dolphin, Annette C.

10

Fuel Cell Technology Status - Voltage Degradation (Presentation)  

SciTech Connect (OSTI)

This presentation describes an independent assessment of fuel cell durability status and discusses the project's relevance to the Department of Energy Hydrogen and Fuel Cells Program; NREL's analysis approach; the FY12 technical accomplishments including the fourth annual publication of results; and project collaborations and future work.

Kurtz, J.; Wipke,; Sprik, S.; Saur, G.

2012-06-01T23:59:59.000Z

11

Analysis of Solar Cell Quality Using Voltage Metrics: Preprint  

SciTech Connect (OSTI)

The highest efficiency solar cells provide both excellent voltage and current. Of these, the open-circuit voltage (Voc) is more frequently viewed as an indicator of the material quality. However, since the Voc also depends on the band gap of the material, the difference between the band gap and the Voc is a better metric for comparing material quality of unlike materials. To take this one step further, since Voc also depends on the shape of the absorption edge, we propose to use the ultimate metric: the difference between the measured Voc and the Voc calculated from the external quantum efficiency using a detailed balance approach. This metric is less sensitive to changes in cell design and definition of band gap. The paper defines how to implement this metric and demonstrates how it can be useful in tracking improvements in Voc, especially as Voc approaches its theoretical maximum.

Toberer, E. S.; Tamboli, A. C.; Steiner, M.; Kurtz, S.

2012-06-01T23:59:59.000Z

12

Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal  

E-Print Network [OSTI]

is too low to be used directly for many practical applications. For example, a single light emitting diode (LED) requires a minimum voltage of 2 V.2 Thus, effective methods of boosting MFC voltages

13

Journal of Power Sources 167 (2007) 1117 Voltage reversal during microbial fuel cell stack operation  

E-Print Network [OSTI]

Journal of Power Sources 167 (2007) 11­17 Voltage reversal during microbial fuel cell stack February 2007; accepted 9 February 2007 Available online 20 February 2007 Abstract Microbial fuel cells Elsevier B.V. All rights reserved. Keywords: Microbial fuel cell; Voltage reversal; Stack; Direct electron

2007-01-01T23:59:59.000Z

14

Electrochemical Characterization of Voltage Fade in LMR-NMC cells  

Broader source: Energy.gov (indexed) [DOE]

the extent of Voltage Fade December 2012 * Establish baseline data on standard materials to facilitate comparison of various datasets March 2013 * Obtain data to determine...

15

State-of-the-Art Fuel Cell Voltage Durability Status: Spring 2013 Composite Data Products  

SciTech Connect (OSTI)

This presentation from the U.S. Department of Energy's National Renewable Energy Laboratory includes composite data products (CDPs) produced in 2013 for state-of-the-art fuel cell voltage durability status.

Kurtz, J.; Sprik, S.; Saur, G.; Peters, M.; Post, M.; Ainscough, C.

2013-05-01T23:59:59.000Z

16

RASRAFMEK-dependent oxidative cell death involving voltage-dependent anion channels  

E-Print Network [OSTI]

LETTERS RAS­RAF­MEK-dependent oxidative cell death involving voltage-dependent anion channels J. Fridman1 , Adam J. Wolpaw1 , Inese Smukste1 , John M. Peltier3 , J. Jay Boniface3 , Richard Smith that discriminate between the genetic makeup of normal cells and tumour cells are valuable for treating and under

Stockwell, Brent R.

17

Method for reducing fuel cell output voltage to permit low power operation  

DOE Patents [OSTI]

Fuel cell performance is degraded by recycling a portion of the cathode exhaust through the cells and, if necessary, also reducing the total air flow to the cells for the purpose of permitting operation below a power level which would otherwise result in excessive voltage.

Reiser, Carl A. (Glastonbury, CT); Landau, Michael B. (West Hartford, CT)

1980-01-01T23:59:59.000Z

18

Electrolytes and Separators for High Voltage Li Ion Cells  

Broader source: Energy.gov [DOE]

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

19

Boosting the voltage of a salinity-gradient-power electrochemical cell by means of complex-forming solutions  

E-Print Network [OSTI]

the diaphragm constitutes a waste of free energy, which impairs the voltage generation of the concentration cell-based light-emitting electrochemical cells J. Appl. Phys. 116, 104504 (2014); 10.1063/1.4895060 Decoupled luminance decay and voltage drift in polymer light-emitting electrochemical cells: Forward bias vs. reverse

Carati, Andrea

20

Effect of voltage dynamics on response properties in a model of sensory hair cell  

E-Print Network [OSTI]

Sensory hair cells in auditory and vestibular organs rely on active mechanisms to achieve high sensitivity and frequency selectivity. Recent experimental studies have documented self-sustained oscillations in hair cells of lower vertebrates on two distinct levels. First, the hair bundle can undergo spontaneous mechanical oscillations. Second, somatic electric voltage oscillations across the baso-lateral membrane of the hair cell have been observed. We develop a biophysical model of the bullfrog's saccular hair cell consisting of two compartments, mechanical and electrical, to study how the mechanical and the voltage oscillations interact to produce coherent self-sustained oscillations and how this interaction contributes to the overall sensitivity and selectivity of the hair cell. The model incorporates nonlinear mechanical stochastic hair bundle system coupled bi-directionally to a Hodgkin-Huxley type system describing somatic ionic currents. We isolate regions of coherent spontaneous oscillations in the par...

Amro, Rami

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Monolithically interconnected GaAs solar cells: A new interconnection technology for high voltage solar cell output  

SciTech Connect (OSTI)

Photovoltaic linear concentrator arrays can benefit from high performance solar cell technologies being developed at AstroPower. Specifically, these are the integration of thin GaAs solar cell and epitaxial lateral overgrowth technologies with the application of monolithically interconnected solar cell (MISC) techniques. This MISC array has several advantages which make it ideal for space concentrator systems. These are high system voltage, reliable low cost monolithically formed interconnections, design flexibility, costs that are independent of array voltage, and low power loss from shorts, opens, and impact damage. This concentrator solar cell will incorporate the benefits of light trapping by growing the device active layers over a low-cost, simple, PECVD deposited silicon/silicon dioxide Bragg reflector. The high voltage-low current output results in minimal 12R losses while properly designing the device allows for minimal shading and resistance losses. It is possible to obtain open circuit voltages as high as 67 volts/cm of solar cell length with existing technology. The projected power density for the high performance device is 5 kW/m for an AMO efficiency of 26% at 1 5X. Concentrator solar cell arrays are necessary to meet the power requirements of specific mission platforms and can supply high voltage power for electric propulsion systems. It is anticipated that the high efficiency, GaAs monolithically interconnected linear concentrator solar cell array will enjoy widespread application for space based solar power needs. Additional applications include remote man-portable or ultra-light unmanned air vehicle (UAV) power supplies where high power per area, high radiation hardness and a high bus voltage or low bus current are important. The monolithic approach has a number of inherent advantages, including reduced cost per interconnect and increased reliability of array connections. There is also a high potential for a large number of consumer products.

Dinetta, L.C.; Hannon, M.H.

1995-10-01T23:59:59.000Z

22

Amorphous silicon/polyaniline heterojunction solar cells: Fermi levels and open-circuit voltages  

E-Print Network [OSTI]

these open-circuit voltages are lower than for the best a-Si:H cells utilizing nanocrystalline Si or a reports on conducting polymer/ amorphous silicon (a-Si:H) structures [1­4] and conduct- ing polymer/crystalline silicon (c-Si) structures [5,6]. In this paper, we report our research on polyaniline (PANI)/a-Si:H

Schiff, Eric A.

23

Quadratic voltage profiles in lead acid cells during slow, steady processes  

E-Print Network [OSTI]

It is standard lore that the voltage profile varies linearly in space within the electrolyte of a lead acid cell under slow, steady discharge. However, this hypothesis has never been put to the test. A recent theory predicts a uniform, non...

Haaser, Robert Anthony

1999-01-01T23:59:59.000Z

24

Abrupt Decline in the Open-Circuit Voltage of Direct Methanol Fuel Cells at Critical Oxygen Feed Rate  

E-Print Network [OSTI]

Abrupt Decline in the Open-Circuit Voltage of Direct Methanol Fuel Cells at Critical Oxygen Feed and Technology, Clear Water Bay, Kowloon, Hong Kong, China The open-circuit voltage OCV of a direct methanol fuel cell DMFC was measured by varying the cathode oxygen flow rate OFR while keeping the methanol

Zhao, Tianshou

25

Automatic voltage imbalance detector  

DOE Patents [OSTI]

A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

1984-01-01T23:59:59.000Z

26

Effect of voltage dynamics on response properties in a model of sensory hair cell  

E-Print Network [OSTI]

Sensory hair cells in auditory and vestibular organs rely on active mechanisms to achieve high sensitivity and frequency selectivity. Recent experimental studies have documented self-sustained oscillations in hair cells of lower vertebrates on two distinct levels. First, the hair bundle can undergo spontaneous mechanical oscillations. Second, somatic electric voltage oscillations across the baso-lateral membrane of the hair cell have been observed. We develop a biophysical model of the bullfrog's saccular hair cell consisting of two compartments, mechanical and electrical, to study how the mechanical and the voltage oscillations interact to produce coherent self-sustained oscillations and how this interaction contributes to the overall sensitivity and selectivity of the hair cell. The model incorporates nonlinear mechanical stochastic hair bundle system coupled bi-directionally to a Hodgkin-Huxley type system describing somatic ionic currents. We isolate regions of coherent spontaneous oscillations in the parameter space of the model and then study how coupling between compartments affect sensitivity of the hair cell to external mechanical perturbations. We show that spontaneous electrical oscillations may enhance significantly the sensitivity and selectivity of the hair cell.

Rami Amro; Alexander B. Neiman

2012-09-27T23:59:59.000Z

27

Voltage Dependent Carrier Collection in CdTe Solar Cells D.L. Btzner1  

E-Print Network [OSTI]

Voltage Dependent Carrier Collection in CdTe Solar Cells D.L. Bätzner1 , Guido Agostinelli2 , A to 1000nm, i.e. the band edge region of CdTe. Region I is further divided in a `blue' part between 300 nm III is as well subdivided in region IIIa from about 800 nm to the band gap of CdTe (~850 nm

Romeo, Alessandro

28

High open circuit voltages of solar cells based on quantum dot and dye hybrid-sensitization  

SciTech Connect (OSTI)

A type of solar cell based on quantum dot (QD) and dye hybrid-sensitized mesoporous TiO{sub 2} film electrode was designed and reported. The electrode was consisted of a TiO{sub 2} nanoparticle (NP) thin film layer sensitized with CdS quantum dot (QD) and an amorphous TiO{sub 2} coated TiO{sub 2} NP thin film layer that sensitized with C106 dye. The amorphous TiO{sub 2} layer was obtained by TiCl{sub 4} post-treatment to improve the properties of solar cells. Research showed that the solar cells fabricated with as-prepared hybrid-sensitized electrode exhibited excellent photovoltaic performances and a fairly high open circuit voltage of 796?mV was achieved.

Zhao, Yujie; Zhao, Wanyu; Chen, Jingkuo; Li, Huayang; Fu, Wuyou, E-mail: hari@hpu.edu.cn, E-mail: fuwy56@163.com; Sun, Guang; Cao, Jianliang; Zhang, Zhanying [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China)] [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China); Bala, Hari, E-mail: hari@hpu.edu.cn, E-mail: fuwy56@163.com [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China) [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China); College of Chemistry and Chemical Engineering, Inner Mongolia University for the Nationalities, Tongliao 028043 (China)

2014-01-06T23:59:59.000Z

29

Modified design of radioisotope thermophotovoltaic generator to mitigate adverse effect of measured cell voltage  

SciTech Connect (OSTI)

A preceding OSC paper described a number of changes in the data base and in the methods--considerably more rigorous than those employed in the past--for analyzing the performance of Radioisotope Thermophotovoltaic (RTPV) converters. As shown, some of those changes were beneficial, but others--particularly the use of EDTEK`s experimentally measured open-circuit voltages and fill factors instead of previously used theoretical equations--had a substantial adverse effect on the predicted converter performance. EDTEK is continuing work on improved PV cells to more closely approach theoretical voltage predictions. In parallel with that effort, OSC has been investigating a number of generator design modifications to achieve additional improvements in system performance. Specifically, OSC found that the converter`s performance could be significantly improved by increasing the heat flux incident on the PV cells. As will be explained, OSC`s preferred design, which entails placing the TPV converters on the housing`s end covers instead of its side walls, not only improves the generator`s performance but also offers important programmatic, fabrication, and processing advantages.

Schock, A.; Or, C.T.; Kumar, V. [Orbital Sciences Corp., Germantown, MD (United States)

1996-12-31T23:59:59.000Z

30

Josh Beale Candidate Statement Nominators  

E-Print Network [OSTI]

Josh Beale ­ Candidate Statement Nominators: Rosa Nobarni Audrey Chan Since I started my university

New South Wales, University of

31

FINE-GRAINED NANOCRYSTALLINE SILICON P-LAYER FOR HIGH OPEN CIRCUIT VOLTAGE A-SI:H SOLAR CELLS  

E-Print Network [OSTI]

FINE-GRAINED NANOCRYSTALLINE SILICON P-LAYER FOR HIGH OPEN CIRCUIT VOLTAGE A-SI:H SOLAR CELLS of Michigan, Ann Arbor, MI 48109, USA ABSTRACT Hydrogenated amorphous silicon (a-Si:H) single- junction solar). It is found that the p-layer that leads to high Voc a-Si:H solar cells is a mixed-phase material that contains

Deng, Xunming

32

contingency Nominal loading margin  

E-Print Network [OSTI]

is estimated. First a nose curve is computed by continuation to obtain a nominal loading margin. Then linear and the very fast computation of the linear estimates. Keywords: Power system security, contingency analy- sis formulas derived in [4]. The computations are summarized: 1 A pattern of load increase, generator dispatch

33

The correlation of open-circuit voltage with bandgap in amorphous silicon-based {ital pin} solar cells  

SciTech Connect (OSTI)

We briefly review the correlation of open-circuit voltages {ital V}{sub OC} with the bandgap of the intrinsic layer in amorphous silicon based {ital pin} solar cells. We discuss two mechanisms which limit {ital V}{sub OC}: intrinsic layer recombination, and the built-in potential {ital V}{sub BI}. In particular we discuss Li{close_quote}s proposal that the open-circuit voltages in higher bandgap cells ({ital E}{sub G}{gt}1.9 eV) are {ital V}{sub BI}-limited. Based on computer simulations of {ital pin} solar cells we propose that {ital V}{sub BI} limitation occurs when the recombination limit to {ital V}{sub OC} exceeds the cell{close_quote}s field-reversal voltage {ital V}{sub R}. For {ital a}-Si:H based cells this field-reversal voltage occurs at about {ital V}{sub BI}-0.3 V. This proposal would account for the observation that {ital V}{sub BI} limitation occurs for {ital V}{sub OC} significantly smaller than {ital V}{sub BI}. {copyright} {ital 1996 American Institute of Physics.}

Crandall, R.S. [National Renewable Energy Laboratory, Golden, Colorado 80401 (United States); Schiff, E.A. [Department of Physics, Syracuse University, Syracuse, New York 13244-1130 (United States)

1996-01-01T23:59:59.000Z

34

Built-in voltage of organic bulk heterojuction p-i-n solar cells measured by electroabsorption spectroscopy  

SciTech Connect (OSTI)

We investigate the influence of the built-in voltage on the performance of organic bulk heterojuction solar cells that are based on a p-i-n structure. Electrical doping in the hole and the electron transport layer allows to tune their work function and hence to adjust the built-in voltage: Changing the doping concentration from 0.5 to 32 wt% induces a shift of the work function towards the transport levels and increases the built-in voltage. To determine the built-in voltage, we use electroabsorption spectroscopy which is based on an evaluation of the spectra caused by a change in absorption due to an electric field (Stark effect). For a model system with a bulk heterojunction of BF-DPB and C{sub 60}, we show that higher doping concentrations in both the electron and the hole transport layer increase the built-in voltage, leading to an enhanced short circuit current and solar cell performance.

Siebert-Henze, E., E-mail: ellen.siebert@iapp.de; Lyssenko, V. G.; Fischer, J.; Tietze, M.; Brueckner, R.; Schwarze, M.; Vandewal, K.; Ray, D.; Riede, M.; Leo, K. [Institut für Angewandte Photophysik, Technische Universität Dresden, D-01062 Dresden (Germany)] [Institut für Angewandte Photophysik, Technische Universität Dresden, D-01062 Dresden (Germany)

2014-04-15T23:59:59.000Z

35

Correlations of Capacitance-Voltage Hysteresis with Thin-Film CdTe Solar Cell Performance During Accelerated Lifetime Testing  

SciTech Connect (OSTI)

In this paper we present the correlation of CdTe solar cell performance with capacitance-voltage hysteresis, defined presently as the difference in capacitance measured at zero-volt bias when collecting such data with different pre-measurement bias conditions. These correlations were obtained on CdTe cells stressed under conditions of 1-sun illumination, open-circuit bias, and an acceleration temperature of approximately 100 degrees C.

Albin, D.; del Cueto, J.

2011-03-01T23:59:59.000Z

36

Open-circuit voltage, fill factor, and efficiency of a CdS/CdTe solar cell  

SciTech Connect (OSTI)

The dependences of the open-circuit voltage, fill factor, and efficiency of the thin-film CdS/CdTe solar cell on the resistivity {rho} and carrier lifetime {tau} in the absorbing CdTe layer were studied. In the common case in which the uncompensated acceptor concentration and the electron lifetime in the CdTe layer are within 10{sup 15}-10{sup 16} cm{sup -3} and 10{sup -10}-10{sup -9} s, the calculation results correspond to the achieved efficiency of the best thin-film CdS/CdTe solar cells. It was shown that, by decreasing {rho} and increasing {tau} in the absorbing CdTe layer, the open-circuit voltage, fill factor, and efficiency can be substantially increased, with their values approaching the theoretical limit for such devices.

Kosyachenko, L. A., E-mail: lakos@chv.ukrpack.net; Grushko, E. V. [Yuriy Fedkovych Chernivtsi National University (Ukraine)

2010-10-15T23:59:59.000Z

37

Effects of n-type doping in InAs/GaAs quantum dot layer on current-voltage characteristic of intermediate band solar cells  

E-Print Network [OSTI]

We investigated the current-voltage characteristic of InAs/GaAs quantum dot intermediate band solar cells (QD IBSCs) with different n-type doping density in the QD layer. The n-type doping evidently increases the open circuit voltage, meanwhile decreases the short circuit current density, and leads to the conversion efficiency approaching that of the control solar cell, that is the major role of n-type doping is to suppress the effects of QDs on the current-voltage characteristic. Our model adopts practical parameters for simulation rather than those from detailed balanced method, so that the results in our simulation are not overestimated.

Gu, Yong-Xian; Ji, Hai-Ming; Xu, Peng-Fei; Yang, Tao

2013-01-01T23:59:59.000Z

38

Effects of applied voltages and dissolved oxygen on sustained power generation by microbial fuel cells  

E-Print Network [OSTI]

Effects of applied voltages and dissolved oxygen on sustained power generation by microbial fuel), Faculty of Advanced Technology, University of Glamorgan, Pontypridd RCT CF37 1DL, UK Oxygen intrusion chamber MFCs at the end of a cycle when the substrate is depleted. A slight increase in dissolved oxygen

39

Comparison of 3 Self-Starting Step-Up DC:DC Converter Topologies for Harvesting Energy from Low-Voltage and Low-Power Microbial Fuel Cells  

E-Print Network [OSTI]

-Voltage and Low-Power Microbial Fuel Cells Nicolas Degrenne1, Bruno Allard2, François Buret1, Florent Morel1.surname@ec-lyon.fr, 2firstname.surname@insa-lyon.fr Keywords «Fuel cell system», , «switched-mode power supply are made according to specifications issued from the stringent characteristics of microbial fuel cells

Paris-Sud XI, Université de

40

Superconducting Coil fed by PEM Fuel Cell M. Hinaje, K. Berger, J. Lvque, B. Davat  

E-Print Network [OSTI]

Superconducting Coil fed by PEM Fuel Cell M. Hinaje, K. Berger, J. Lévêque, B. Davat Université de, 54516 Vandoeuvre-lès-Nancy, France Melika.Hinaje@univ-lorraine.fr Abstract- Fuel cells and around 0.6 V in nominal conditions of power generation. Fuel cells are then by essence low voltage

Boyer, Edmond

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Characterization of Voltage Fade in Lithium-ion Cells with Layered...  

Broader source: Energy.gov (indexed) [DOE]

4.65 V charge peak Technical Accomplishments and Progress 2.2 2.6 3 3.4 3.8 4.2 4.6 dQdV Equivalent Voltage vs. LiLi + , V 3.15 3.5 3.8 4.65 3.9 2.95 4.4 4.4 After activation 100...

42

WYSS TECHNOLOGY DEVELOPMENT FELLOWSHIP NOMINATION FORM  

E-Print Network [OSTI]

WYSS TECHNOLOGY DEVELOPMENT FELLOWSHIP NOMINATION FORM 1. Biographical Sketch _____________________________________________ ________________________________________ Wyss Enabling Technology Platform Focus research plans relative to Wyss Enabling Technology Platform. 3. Enclose supporting letter from nominator

43

Agency Energy Coordinators for Award Nominations  

Broader source: Energy.gov [DOE]

Federal agency energy coordinators handle all nominations for the Federal Energy and Water Management Awards.

44

Study of band bending effect in Dye Sensitized Solar Cell through Constant-Current-Discharging Voltage Decay  

E-Print Network [OSTI]

A measurement method of constant-current-discharging voltage decay is established to characterize the band bending effect in the heterojunction of conducting glass/TiO2 for typical dye-sensitized solar cells. Furthermore, a dark-state electron transport regarding the TiO2 conduction band bending is proposed based upon the viewpoints of thermionic emission mechanism, which suggests an origin of the band bending effect in a theoretical model. This model quantitatively agrees well with our experimental results and indicates that both the Fermi level decay in TiO2 and the potential difference across the heterojunction will lead to the TiO2 conduction band bending downwards.

Wang, Xiaoqi

2012-01-01T23:59:59.000Z

45

International Phenomenological Society On Nominalism  

E-Print Network [OSTI]

International Phenomenological Society On Nominalism Author(s): Geoffrey Hellman Source: Philosophy and Phenomenological Research, Vol. 62, No. 3 (May, 2001), pp. 691-705 Published by: International Phenomenological contact support@jstor.org. . International Phenomenological Society is collaborating with JSTOR

Hellman, Geoffrey

46

Federal Energy and Water Management Awards: Nomination Quick...  

Energy Savers [EERE]

Nomination Quick Reference Federal Energy and Water Management Awards: Nomination Quick Reference Document offers a checklist of items needed to complete a nomination for the 2015...

47

2015 Federal Energy and Water Management Awards: Nomination Quick...  

Energy Savers [EERE]

Nomination Quick Reference 2015 Federal Energy and Water Management Awards: Nomination Quick Reference Document offers a checklist of items needed to complete a nomination for the...

48

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2012 DOE Hydrogen and Fuel Cells Program and...

49

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Broader source: Energy.gov (indexed) [DOE]

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2013 DOE Hydrogen and Fuel Cells Program and...

50

W. ROBERT NIX ART EDUCATION SCHOLARSHIP NOMINATION  

E-Print Network [OSTI]

W. ROBERT NIX ART EDUCATION SCHOLARSHIP NOMINATION 2014-2015 Please return completed form to Courtney Baron in room C301H by April 15, 2014. The Art Education Area nominates_____________________________________________ for the W. Robert Nix Art Education Scholarship for ______________________ semester

Arnold, Jonathan

51

210 nature neuroscience volume 5 no 3 march 2002 Calcium entry into cells through voltage-gated Ca2+ channels  

E-Print Network [OSTI]

voltage-gated Ca2+ channels initiates a wide range of cellular processes including protein phosphorylation, gene expression and neurotransmitter release1. Neuronal Ca2+ channels consist of a pore-forming 1 by neurotransmitters inhibits Cav2.1 and Cav2.2 channels, which mediate P/Q-type and N- type Ca2+ currents

Palczewski, Krzysztof

52

Development of a technique for ex-reactor heating of electrodes and for obtaining voltage-current characteristics of multi-cell thermionic fuel elements  

SciTech Connect (OSTI)

This paper presents results of development of a technique for ex-reactor heating with simultaneous recording of voltage-current characteristics of multi-cell thermionic fuel elements (TFE). Heating pulses were applied to electrodes of a thermionic energy converter (TIC), and between these pulses in the antiphase to them there were applied shorter pulses. The TIC emitter was heated by energy of an electric current flowing from the collector (back current heating). Comparison of TIC voltage-current characteristics, obtained for direct (using electric heater) and back current (current from the collector) heating, shows that for the same conditions they differ only slightly. Significant difference may be observed in the case of different profiles along the collector working surface. Results are given of the investigation of multi-cell thermionic fuel assemblies conducted using this technique. The developed technique of the TFE diagnostics can be successfully employed to assess the device quality. Pre-loop testing of multi-cell TFE by the method of back currents allows for cost effective and expeditious thermovacuum treatment of the TFE on thermal stands and for checking of its serviceability prior to its mounting into an irradiation loop or reactor-converter, enables improvements to the TFE design, monitoring of its electric parameters, for example, after vibration testing, and TFE accelerated testing in the most arduous conditions (thermocycling, loss of vacuum, etc.).

Kalandarishvili, A.G.; Mailov, G.M.; Igumnov, B.N.; Bisko, V.A. [I.N. Vekua Sukhumi Inst. for Physics and Engineering, Tbilisi (Georgia)

1995-12-31T23:59:59.000Z

53

Theoretical Analysis of Effects of Deep Level, Back Contact, and Absorber Thickness on Capacitance-Voltage Profiling of CdTe Thin-Film Solar Cells  

SciTech Connect (OSTI)

The apparent carrier density profile measured by the capacitance-voltage technique in CdTe thin-film solar cells frequently displays a distinctive U-shape. We show that, even assuming a uniform carrier density, such a U-shape may arise from deep levels, a non-ohmic back-contact, and a thin absorber, which are commonly present in practical CdTe thin-film solar cells. A thin CdTe absorber contributes to the right branch of the U-shape due to a punch-through effect at reverse or zero biases, when the CdTe absorber is nearly fully depleted. A rectifying back-contact contributes to both branches of the U-shape due to voltage sharing with the front junction under a forward bias and early punch-through under a reverse bias. Deep levels contribute to the right branch, but also raise the bottom of the U-shape, leading to an overestimate of carrier density.

Li, J. V.; Halverson, A. F.; Sulima, O. V.; Bansal, S.; Burst, J. M.; Barnes, T. M.; Gessert, T. A.; Levi, D. H.

2012-05-01T23:59:59.000Z

54

Additions to list of Nominating Bodies Organisation Website and Address Qualifications for nominating  

E-Print Network [OSTI]

Annex A Additions to list of Nominating Bodies Organisation Website and Address Qualifications plc is the world's leading semiconductor intellectual property supplier. Instead of bearing the costs

Glasgow, University of

55

Understanding S-shaped current-voltage characteristics of organic solar cells: Direct measurement of potential distributions by scanning Kelvin probe  

SciTech Connect (OSTI)

We present a comparison of the potential distribution along the cross section of bilayer poly(3-hexylthiophene)/1-(3-methoxycarbonyl)propyl-1-phenyl[6,6]C61 (P3HT/PCBM) solar cells, which show normal and anomalous, S-shaped current-voltage (IV) characteristics. We expose the cross sections of the devices with a focussed ion beam and measure them with scanning Kelvin probe microscopy. We find that in the case of S-shaped IV-characteristics, there is a huge potential drop at the PCBM/Al top contact, which does not occur in solar cells with normal IV-characteristics. This behavior confirms the assumption that S-shaped curves are caused by hindered charge transport at interfaces.

Saive, Rebecca, E-mail: rebecca.saive@innovationlab.de; Kowalsky, Wolfgang [InnovationLab GmbH, 69115 Heidelberg (Germany) [InnovationLab GmbH, 69115 Heidelberg (Germany); Institut für Hochfrequenztechnik, TU Braunschweig, 38106 Braunschweig (Germany); Kirchhoff-Institute for Physics, Heidelberg University, 69120 Heidelberg (Germany); Mueller, Christian [InnovationLab GmbH, 69115 Heidelberg (Germany) [InnovationLab GmbH, 69115 Heidelberg (Germany); Kirchhoff-Institute for Physics, Heidelberg University, 69120 Heidelberg (Germany); Schinke, Janusz; Lovrincic, Robert [InnovationLab GmbH, 69115 Heidelberg (Germany) [InnovationLab GmbH, 69115 Heidelberg (Germany); Institut für Hochfrequenztechnik, TU Braunschweig, 38106 Braunschweig (Germany)

2013-12-09T23:59:59.000Z

56

Cerebellar Purkinje cell death in the P/Q -type voltage-gated calcium ion channel mutant mouse, leaner  

E-Print Network [OSTI]

inducing an inflammatory response in the tissue surrounding the affected cell (Sastry and Rao, 2000; Yuan and Yankner, 2000; Yuan, et al., 2003). Programmed cell death is an essential requirement for normal neurodevelopment and a key component of many...

Frank-Cannon, Tamy Catherine

2006-04-12T23:59:59.000Z

57

Vehicle Technologies Office Merit Review 2014: Characterization of Voltage Fade in Lithium-ion Cells with Layered Oxides  

Broader source: Energy.gov [DOE]

Presentation given by Argonne National Laboratory at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about characterization...

58

Neurodegeneration in cerebellar granule cells of p/q type voltage gated calcium channel mutant leaner mice  

E-Print Network [OSTI]

the extent of neuronal cell death, basal intracellular calcium and mitochondrial (dys)function in cerebellar granule cells (CGC) of adult leaner mice; 2) to analyze the role of the leaner calcium channel mutation on postnatal development of CGCs; and 3...

Bawa, Bhupinder

2009-05-15T23:59:59.000Z

59

The effects of fabrication temperature on current-voltage characteristics and energy efficiencies of quantum dot sensitized ZnOH-GO hybrid solar cells  

SciTech Connect (OSTI)

The effects of fabrication temperature are investigated on the performance of CdSe quantum dot (QD)-sensitized hybrid solar cells of the composite material of zinc (hydr)oxide (ZnOH-GO)with 2?wt.?% graphite oxide. The current-voltage (I-V) and photo-current measurements show that higher fabrication temperatures yield greater photovoltaic power conversion efficiencies that essentially indicate more efficient solar cells. Two Photon Fluorescence images show the effects of temperature on the internal morphologies of the solar devices based on such materials. The CdSe-QD sensitized ZnOH-GO hybrid solar cells fabricated at 450?°C showing conversion of ?10.60% under a tungsten lamp (12.1 mW/cm{sup 2}) are reported here, while using potassium iodide as an electrolyte. The output photocurrent, I (?A) with input power, P (mW/cm{sup 2}) is found to be superlinear, showing a relation of I?=?P{sup n}, where n?=?1.4.

Islam, S. M. Z. [IUSL, Department of Physics, The City College of New York, 160 Convent Ave., New York, New York 10031 (United States); Department of Physics and Engineering Physics, Fordham University, 441 E. Fordham Road, Bronx, New York 10458 (United States); Department of Electrical Engineering, The City College of New York, 160 Convent Ave., New York, New York 10031 (United States); Gayen, Taposh [IUSL, Department of Physics, The City College of New York, 160 Convent Ave., New York, New York 10031 (United States); Department of Physics and Engineering Physics, Fordham University, 441 E. Fordham Road, Bronx, New York 10458 (United States); Tint, Naing; Alfano, Robert, E-mail: ralfano@sci.ccny.cuny.edu [IUSL, Department of Physics, The City College of New York, 160 Convent Ave., New York, New York 10031 (United States); Department of Electrical Engineering, The City College of New York, 160 Convent Ave., New York, New York 10031 (United States); Shi, Lingyan [IUSL, Department of Physics, The City College of New York, 160 Convent Ave., New York, New York 10031 (United States); Department of Biomedical Engineering, The City College of New York, 160 Convent Ave., New York, New York 10031 (United States); Seredych, Mykola; Bandosz, Teresa J. [Department of Chemistry, The City College of New York, 160 Convent Ave., New York, New York 10031 (United States)

2014-11-07T23:59:59.000Z

60

Concrete Domains and Nominals United Carlos Areces  

E-Print Network [OSTI]

Concrete Domains and Nominals United Carlos Areces University of Amsterdam The Netherlands carlos(D), the extension of ALC with concrete domains, is known to be PSpace-complete, in this article we show on the concrete domain D used). The proof is by a reduction of a NExpTime-complete variant of the domino problem

Lutz, Carsten

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

NOMINAL RISK Development or Equipment Acquisition Grants  

E-Print Network [OSTI]

NOMINAL RISK Development or Equipment Acquisition Grants Land Grants Planning Grants Required and at the grant's closeout. The FAA audit recommended develop- ing a risk-based approach to monitoring grant levels of risk are identified to rank each sponsor, and the rank deter- mines the level of grant

Minnesota, University of

62

Full Abstraction for Nominal General References  

E-Print Network [OSTI]

}. For each m (MA \\ IA): iA A m1 A · · · A mi A m Initial moves are P-Answers,and whenever m1 A m2, m1, m2 The -calculus is a functional calculus with nominal references. TY A, B ::= ½ | � | [A] | A B | A B TE M, N ::= x | x.M | M N -term | skip return | n | pred M | succ N arithmetic | if0 M then N1 else N2

63

Nominal Performance Biosphere Dose Conversion Factor Analysis  

SciTech Connect (OSTI)

The purpose of this report was to document the process leading to development of the Biosphere Dose Conversion Factors (BDCFs) for the postclosure nominal performance of the potential repository at Yucca Mountain. BDCF calculations concerned twenty-four radionuclides. This selection included sixteen radionuclides that may be significant nominal performance dose contributors during the compliance period of up to 10,000 years, five additional radionuclides of importance for up to 1 million years postclosure, and three relatively short-lived radionuclides important for the human intrusion scenario. Consideration of radionuclide buildup in soil caused by previous irrigation with contaminated groundwater was taken into account in the BDCF development. The effect of climate evolution, from the current arid conditions to a wetter and cooler climate, on the BDCF values was evaluated. The analysis included consideration of different exposure pathway's contribution to the BDCFs. Calculations of nominal performance BDCFs used the GENII-S computer code in a series of probabilistic realizations to propagate the uncertainties of input parameters into the output. BDCFs for the nominal performance, when combined with the concentrations of radionuclides in groundwater allow calculation of potential radiation doses to the receptor of interest. Calculated estimates of radionuclide concentration in groundwater result from the saturated zone modeling. The integration of the biosphere modeling results (BDCFs) with the outcomes of the other component models is accomplished in the Total System Performance Assessment (TSPA) to calculate doses to the receptor of interest from radionuclides postulated to be released to the environment from the potential repository at Yucca Mountain.

Wasiolek, Maryla A.

2000-12-21T23:59:59.000Z

64

High Voltage Safety Act  

Broader source: Energy.gov [DOE]

The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage...

65

DOE Encourages Utility Sector Nominations to the Federal Communication...  

Broader source: Energy.gov (indexed) [DOE]

the Federal Communications Commission's Communications, Security, Reliability, and Interoperability Council DOE Encourages Utility Sector Nominations to the Federal Communications...

66

2015 Federal Energy and Water Management Awards: Nomination Quick Reference  

Broader source: Energy.gov [DOE]

Document offers a checklist of items needed to complete a nomination for the 2015 Federal Energy and Water Management Awards.

67

High voltage photovoltaic power converter  

DOE Patents [OSTI]

An array of independently connected photovoltaic cells on a semi-insulating substrate contains reflective coatings between the cells to enhance efficiency. A uniform, flat top laser beam profile is illuminated upon the array to produce electrical current having high voltage. An essentially wireless system includes a laser energy source being fed through optic fiber and cast upon the photovoltaic cell array to prevent stray electrical signals prior to use of the current from the array. Direct bandgap, single crystal semiconductor materials, such as GaAs, are commonly used in the array. Useful applications of the system include locations where high voltages are provided to confined spaces such as in explosive detonation, accelerators, photo cathodes and medical appliances.

Haigh, Ronald E. (Arvada, CO); Wojtczuk, Steve (Cambridge, MA); Jacobson, Gerard F. (Livermore, CA); Hagans, Karla G. (Livermore, CA)

2001-01-01T23:59:59.000Z

68

ccsd-00014522,version1-5Oct2006 Co-transport-induced instability of membrane voltage in tip-growing cells  

E-Print Network [OSTI]

ccsd-00014522,version1-5Oct2006 Co-transport-induced instability of membrane voltage in tip at the same time. It is shown that these co-transporters destabilize generically the membrane voltage- tive dynamics and activity of membrane ion channels. Action potential and cardiac excitation spiral

Paris-Sud XI, Université de

69

Vehicle Technologies Office Merit Review 2014: Voltage Fade,...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Voltage Fade, an ABR Deep Dive Project: Status and Outcomes Presentation given by Argonne National Laboratory at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle...

70

Optical voltage reference  

DOE Patents [OSTI]

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

71

Voltage Control Technical Conference  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Intro Voltage Control Conference - BPA Active Power Control in Wind Parks - Siemens Interconnection Criteria for Frequency Response Requirements - NERC Model Validation...

72

Multilevel Cascade H-bridge Inverter DC Voltage Estimation Through Output Voltage Sensing  

E-Print Network [OSTI]

system as the inverter power supply may vary. For example, interface of solar panels or fuel cell. The output voltage is then processed by a DSP unit that uses the signals that command the switches

Tolbert, Leon M.

73

A Multiattribute Utility Analysis of Sites Nominated For Characterizat...  

Broader source: Energy.gov (indexed) [DOE]

A Multiattribute Utility Analysis of Sites Nominated For Characterization For the First Radioactive Waste Repository - A Decision Aiding Methodology A Multiattribute Utility...

74

Open Nominations Call - Energy Department Employees, Join the...  

Broader source: Energy.gov (indexed) [DOE]

Nominations Call - Energy Department Employees, Join the Women @ Energy Series Dot Harris Dot Harris Director, Office of Economic Impact and Diversity In honor of Women's...

75

Voltage verification unit  

DOE Patents [OSTI]

A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

Martin, Edward J. (Virginia Beach, VA)

2008-01-15T23:59:59.000Z

76

Voltage balanced multilevel voltage source converter system  

DOE Patents [OSTI]

A voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

77

Voltage balanced multilevel voltage source converter system  

DOE Patents [OSTI]

Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-07-01T23:59:59.000Z

78

NOMINATION FORM 2010 Distinguished Texan in Agriculture Award  

E-Print Network [OSTI]

NOMINATION FORM 2010 Distinguished Texan in Agriculture Award Texas A&M AgriLife The Texas A/her contributions on behalf of the Texas agricultural industry and community (information may be submitted:__________________________________________________________ ________________________________________________________________________ RETURN NOMINATIONS TO 2010 Distinguished Texan in Agriculture Selection Advisory Committee c/o Office

79

High voltage DC power supply  

DOE Patents [OSTI]

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

Droege, T.F.

1989-12-19T23:59:59.000Z

80

High voltage DC power supply  

DOE Patents [OSTI]

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

Droege, Thomas F. (Batavia, IL)

1989-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

2011 NOMINATIONS REPORT As Past President of the University of Saskatchewan Alumni Association, Chair of the Nominations Committee and Chair  

E-Print Network [OSTI]

2011 NOMINATIONS REPORT As Past President of the University of Saskatchewan Alumni Association of Saskatchewan Alumni Association Board of Directors: The Nominations Committee hereby recommends of Saskatchewan Alumni Association's 95th Annual General Meeting on June 16, 2011: For one year terms to begin

Saskatchewan, University of

82

Distinguished Alumni Awards Nomination Form 2008  

E-Print Network [OSTI]

________________________________________________________ Business Phone ______________________ Home Phone _____________________ Cell Phone _________________E Drive Salt Lake City, UT 84112 Phone: 581-6995 FAX: 581-3711 Nominee Information Name _______________________________________ Phone_______________________________ Company

Capecchi, Mario R.

83

ABBGroup-1-High voltage lab  

E-Print Network [OSTI]

oscillations are due to travelling waves in the heating volume. #12;©ABBGroup-9- 3-Sep-07 2. High voltage phase interrupts the injected current, it is stressed by the transient recovery voltage (TRV) oscillating©ABBGroup-1- 3-Sep-07 High voltage lab Research on high voltage gas circuit breakers Nils P. Basse

Basse, Nils Plesner

84

Electron launching voltage monitor  

DOE Patents [OSTI]

An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors. 5 figs.

Mendel, C.W.; Savage, M.E.

1992-03-17T23:59:59.000Z

85

Voltage controlled current source  

DOE Patents [OSTI]

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, Gregory M. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

86

Statement from Energy Secretary Samuel W. Bodman on the Nomination...  

Energy Savers [EERE]

of Thomas P. D'Agostino as Under Secretary for Nuclear Security and Administrator of NNSA Statement from Energy Secretary Samuel W. Bodman on the Nomination of Thomas P....

87

A Review Of Water Contents Of Nominally Anhydrous Natural Minerals...  

Open Energy Info (EERE)

Water Contents Of Nominally Anhydrous Natural Minerals In The Mantles Of Earth, Mars And The Moon Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal...

88

Do parties still matter? : the politics of gubernatorial nominations  

E-Print Network [OSTI]

Who controls the nomination in gubernatorial elections? This dissertation seeks to answer this simple question. Parties have classically been the organizations held responsible for throwing their collective effort behind ...

Cobb, Rachael V

2006-01-01T23:59:59.000Z

89

Section IV.D.3 for DOE 2013 Annual Report: Novel Phosphazene-based Compounds to Enhance Safety and Stability of Cell Chemistries for High Voltage Applications (INL)  

SciTech Connect (OSTI)

Electrolytes play a central role in performance and aging in most electrochemical systems. As automotive and grid applications place a higher reliance on electrochemical stored energy, it becomes more urgent to have electrolyte components that enable optimal battery performance while promoting battery safety and longevity. Safety remains a foremost concern for widespread utilization of Li-ion technology in electric-drive vehicles, especially as the focus turns to higher voltage systems (5V). This work capitalizes on the long established INL expertise regarding phosphazene chemistry, aimed at battery-viable compounds for electrolytes and electrodes that are highly tolerant to abusive conditions. This report showcases our 2013 work for the DOE applied battery research (ABR) program, wherein testing results are summarized for INL electrolytes and alternative anode materials.

Kevin L. Gering; Mason K. Harrup; Eric J. Dufek; Sergiy V. Sazhin; Harry W. Rollins; David K. Jamison; Fred F. Stewart; John Burba

2013-09-01T23:59:59.000Z

90

High voltage pulse conditioning  

DOE Patents [OSTI]

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

1990-01-01T23:59:59.000Z

91

Charge-pump voltage converter  

DOE Patents [OSTI]

A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

Brainard, John P. (Albuquerque, NM); Christenson, Todd R. (Albuquerque, NM)

2009-11-03T23:59:59.000Z

92

INTEGRATED GHz VOLTAGE CONTROLLED OSCILLATORS  

E-Print Network [OSTI]

INTEGRATED GHz VOLTAGE CONTROLLED OSCILLATORS Peter Kinget Bell Labs - Lucent Technologies Murray Hill, NJ (USA) Abstract The voltage controlled oscillator (VCO) is a critical sub. We focus on the de- sign of a critical sub-block: the voltage controlled oscillator (VCO). We review

Kinget, Peter

93

Peculiarities of a method for ex-reactor heating of electrodes and obtaining voltage-current characteristics of multi-cell thermionic fuel elements  

SciTech Connect (OSTI)

The paper discusses principle of operation and applications of a pulse method of heating multi-cell thermionic fuel elements. Some experimental results are given for a cylindrical single-cell thermionic energy converter that simulates conditions close to that of multi-cell TFE operation. Basic requirements for technical parameters are stated that should be observed when testing TFE on thermal facilities. The means to improve the method are described, including both a computer-aided experiment and modifications in individual components of the test facility. {copyright} {ital 1996 American Institute of Physics.}

Kalandarishvili, A.G. [Sukhumi Institute of Physics and Engineering, Tbilisi 380008 Republic of (Georgia); Drozdov, A.A. [RRC ``Kurchatov Institute``, Moscow 123182 (Russia); Stepennov, B.S. [INERTEK, Moscow 123182 (Russia)

1996-03-01T23:59:59.000Z

94

Vehicle Technologies Office Merit Review 2014: High Energy Density Li-ion Cells for EV’s Based on Novel, High Voltage Cathode Material Systems  

Broader source: Energy.gov [DOE]

Presentation given by Farasis Energy, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high energy density Li...

95

Analysis of Hippocampal Cell Proliferation, Survival, and Neuronal Morphology in P/Q-Type Voltage-Gated Calcium Channel Mutant Mice  

E-Print Network [OSTI]

regulates important Ca2+-dependent neuronal processes including neurotransmitter release and synaptogenesis, we assessed effects of these mutations on hippocampus volume, neuronal density, neuronal morphology of hippocampal pyramidal cells in adult (six...

Nigussie, Fikru

2013-01-16T23:59:59.000Z

96

Ignition distributor voltage generator  

SciTech Connect (OSTI)

This patent describes a voltage pulse generator and ignition distributor comprising, a base, a shaft rotatably supported by the base, a distributor cap supported by the base having a center electrode and circumferentially spaced outer electrodes. The pulse generator and ignition distribution also include a first rotor driven by the shaft formed of electrical insulating material having electrically conductive means connected to the center terminal and a portion that rotates past the outer electrodes. The portion of the electrically conductive means that rotates past the outer electrodes is spaced from the outer electrodes to form a gap therebetween. A voltage pulse generator comprises a second rotor driven by the shaft, at least one permanent magnet and an annular pickup coil supported by the base. The pickup coil has inner turns and outer turns, the beginning turn of the inner turns connected to a first lead and the last turn of the outer turns connected to a second lead, the outer turns enclosing the inner turns. The pickup coil also has a circuit connected directly between the second lead and ground which is operative to provide a direct conductive path to ground for high frequency energy capacitively coupled to the outer turns from the gap discharge between the electrically conductive means of the first rotor and an outer electrode, the outer turns forming a grounded shield for the inner turns.

Boyer, J.A.

1986-11-04T23:59:59.000Z

97

STUDENT EMPLOYEE OF THE YEAR AWARD NOMINATION FORM  

E-Print Network [OSTI]

STUDENT EMPLOYEE OF THE YEAR AWARD NOMINATION FORM Nominees must be full-time, undergraduate, degree-seeking students and have at least one semester of employment as a student worker) for the University of Memphis as paid, student assistants. Generally student workers may be classified as "Work

Dasgupta, Dipankar

98

UNIVERSITY OF SASKATCHEWAN NOMINATION TO THE UNIVERSITY OF SASKATCHEWAN SENATE  

E-Print Network [OSTI]

UNIVERSITY OF SASKATCHEWAN NOMINATION TO THE UNIVERSITY OF SASKATCHEWAN SENATE The University of Saskatchewan Act 1995 (24.3) provides for membership on the University of Saskatchewan Senate by professional to the social, economic and cultural welfare of Saskatchewan; and (b) have a demonstrated interest in furthering

Saskatchewan, University of

99

Spark-safe low-voltage detonator  

DOE Patents [OSTI]

A column of explosive in a low-voltage detonator which makes it spark-safe ncludes an organic secondary explosive charge of HMX in the form of a thin pad disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to an electrical ignition device at one end of the bore. The pad of secondary charge has an axial thickness within the range of twenty to thirty percent of its diameter. The explosive column also includes a first explosive charge of CP disposed in the housing bore in the ignition region of the explosive column next to the secondary charge pad on a side opposite from the ignition device. The first CP charge is loaded under sufficient pressure, 25 to 40 kpsi, to provide mechanical confinement of the pad of secondary charge and physical coupling thereof with the ignition device. The explosive column further includes a second explosive charge of CP disposed in the housing bore in a transition region of the explosive column next to the first CP charge on a side opposite from the pad of secondary charge. The second CP charge is loaded under sufficient pressure, about 10 kpsi, to allow occurrence of DDT. The first explosive CP charge has an axial thickness within the range of twenty to thirty percent of its diameter, whereas the second explosive CP charge contains a series of increments (nominally 4) each of which has an axial thickness-to-diameter ratio of one to two.

Lieberman, Morton L. (Albuquerque, NM)

1989-01-01T23:59:59.000Z

100

Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect (OSTI)

An update is given on the work of the PV Quality Assurance Task Force; Group 3: studying the effects of humidity, temperature, and voltage bias.

Wohlgemuth, J.

2012-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

The role of linear and voltage-dependent ionic currents in the generation of slow wave oscillations  

E-Print Network [OSTI]

The role of linear and voltage-dependent ionic currents in the generation of slow wave oscillations voltages, re- spectively. Oscillations are created by inward currents driving the cell away from rest voltages and one outward current that repolarizes the cell. Such currents have traditionally been assumed

Bose, Amitabha

102

Transient voltage oscillations in coils  

SciTech Connect (OSTI)

Magnet coils may be excited into internal voltage oscillations by transient voltages. Such oscillations may electrically stress the magnet's dielectric components to many times its normal stress. This may precipitate a dielectric failure, and the attendant prolonged loss of service and costly repair work. Therefore, it is important to know the natural frequencies of oscillations of a magnet during the design stage, and to determine whether the expected switching transient voltages can excite the magnet into high-voltage internal oscillations. The series capacitance of a winding significantly affects its natural frequencies. However, the series capacitance is difficult to calculate, because it may comprise complex capacitance network, consisting of intra- and inter-coil turn-to-turn capacitances of the coil sections. A method of calculating the series capacitance of a winding is proposed. This method is rigorous but simple to execute. The time-varying transient voltages along the winding are also calculated.

Chowdhuri, P.

1985-01-01T23:59:59.000Z

103

Nominal symbols and their contribution to selected Guardian essays  

E-Print Network [OSTI]

: Dr. Harry P. Kroitor Nominal symbols were commonly used in periodical essays during the seventeenth and eighteenth centuries and the Guardian, written primarily by Sir Richard Steele and Joseph Addison, is no exception. Characters... times, to eighteenth-century British essayists, the name often made the man. In the Guardian, a series of 175 essays presented by the controlling persona Nestor Ironside and written by Sir Richard Steele, Joseph Addison, and some...

Dunsford, Deborah Williams

1987-01-01T23:59:59.000Z

104

Process Options for Nominal 2-K Helium Refrigeration System Designs  

SciTech Connect (OSTI)

Nominal 2-K helium refrigeration systems are frequently used for superconducting radio frequency and magnet string technologies used in accelerators. This paper examines the trade-offs and approximate performance of four basic types of processes used for the refrigeration of these technologies; direct vacuum pumping on a helium bath, direct vacuum pumping using full or partial refrigeration recovery, cold compression, and hybrid compression (i.e., a blend of cold and warm sub-atmospheric compression).

Peter Knudsen, Venkatarao Ganni

2012-07-01T23:59:59.000Z

105

Quantitative and qualitative productivity in nominal brainstorming groups  

E-Print Network [OSTI]

. A. , Lorna Linda University Chair of Committee: Dr. Charles Samuelson This research investigated the effects of evaluation apprehension and social comparison feedback on the quantitative and qualitative productivity of brainstorming. Both... with these characteristics. However, this study goes one step further and uses truly nominal groups in order to isolate the effects of evaluation apprehension and social comparison feedback. One hundred three undergraduate students were used to investigate the following...

Selivanoff, Sophia G

1989-01-01T23:59:59.000Z

106

Low voltage nonprimary explosive detonator  

DOE Patents [OSTI]

A low voltage, electrically actuated, nonprimary explosive detonator is disclosed wherein said detonation is achieved by means of an explosive train in which a deflagration-to-detonation transition is made to occur. The explosive train is confined within a cylindrical body and positioned adjacent to low voltage ignition means have electrical leads extending outwardly from the cylindrical confining body. Application of a low voltage current to the electrical leads ignites a self-sustained deflagration in a donor portion of the explosive train which then is made to undergo a transition to detonation further down the train.

Dinegar, Robert H. (Los Alamos, NM); Kirkham, John (Newbury, GB2)

1982-01-01T23:59:59.000Z

107

Voltage tunable microwave ferrite resonator  

E-Print Network [OSTI]

A novel method of implementing a tunable resonator using an applied voltage is presented. Stress is used to tune a microstrip resonator fabricated on a polycrystalline ferrite substrate. The stress was applied either ...

Oates, Daniel E.

108

Saving Megawatts with Voltage Optimization  

E-Print Network [OSTI]

that had been installed at several electric utility distribution substations in the U.S. and Canada. These systems, being operated in Conservation Voltage Regulation mode, have provided significant energy conservation where they have been installed...

Wilson, T.; Bell, D.

2010-01-01T23:59:59.000Z

109

Spark-safe low-voltage detonator  

DOE Patents [OSTI]

A column of explosive in a low-voltage detonator which makes it spark-safe includes an organic secondary explosive charge of HMX in the form of a thin pad disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to an electrical ignition device at one end of the bore. The pad of secondary charge has an axial thickness within the range of twenty to thirty percent of its diameter. The explosive column also includes a first explosive charge of CP disposed in the housing bore in the ignition region of the explosive column next to the secondary charge pad on a side opposite from the ignition device. The first CP charge is loaded under sufficient pressure, 25 to 40 kpsi, to provide mechanical confinement of the pad of secondary charge and physical coupling thereof with the ignition device. The explosive column further includes a second explosive charge of CP disposed in the housing bore in a transition region of the explosive column next to the first CP charge on a side opposite from the pad of secondary charge. The second CP charge is loaded under sufficient pressure, about 10 kpsi, to allow occurrence of DDT. The first explosive CP charge has an axial thickness within the range of twenty to thirty percent of its diameter, whereas the second explosive CP charge contains a series of increments (nominally 4), each of which has an axial thickness-to-diameter ratio of one to two. 2 figs.

Lieberman, M.L.

1988-07-01T23:59:59.000Z

110

Multilevel cascade voltage source inverter with seperate DC sources  

DOE Patents [OSTI]

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

111

Multilevel cascade voltage source inverter with separate DC sources  

DOE Patents [OSTI]

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-06-24T23:59:59.000Z

112

Multilevel cascade voltage source inverter with seperate DC sources  

DOE Patents [OSTI]

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

Peng, Fang Zheng (Knoxville, TN); Lai, Jih-Sheng (Blacksburg, VA)

2002-01-01T23:59:59.000Z

113

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents [OSTI]

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components.

Duckworth, Douglas C. (Knoxville, TN); Marcus, R. Kenneth (Clemson, SC); Donohue, David L. (Vienna, AT); Lewis, Trousdale A. (Oak Ridge, TN)

1994-01-01T23:59:59.000Z

114

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents [OSTI]

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

1994-06-28T23:59:59.000Z

115

Classification : Original Article VOLTAGE-GATED SODIUM CHANNELS POTENTIATE THE INVASIVE  

E-Print Network [OSTI]

- gated sodium channels in non-small-cell lung cancer cell lines. Functional voltage-gated sodium channels cancerous cell lines H23, H460 and Calu-1 possess functional sodium channels while normal and weakly metastatic cell lines do not. While all the cell lines expressed mRNA for numerous sodium channel isoforms

Boyer, Edmond

116

Voltage, energy and power in electric circuits  

E-Print Network [OSTI]

Voltage, energy and power in electric circuits Science teaching unit #12;Disclaimer The Department-2008DVD-EN Voltage, energy and power in electric circuits #12;#12;© Crown copyright 2008 1The National Strategies | Secondary Voltage, energy and power in electric circuits 00094-2008DVD-EN Contents Voltage

Berzins, M.

117

Ancillary service details: Voltage control  

SciTech Connect (OSTI)

Voltage control is accomplished by managing reactive power on an alternating-current power system. Reactive power can be produced and absorbed by both generation and transmission equipment. Reactive-power devices differ substantially in the magnitude and speed of response and in their capital costs. System operators, transmission owners, generators, customers, power marketers, and government regulators need to pay close attention to voltage control as they restructure the U.S. electricity industry. Voltage control can affect reliability and commerce in three ways: (1) Voltages must be maintained within an acceptable range for both customer and power-system equipment to function properly. (2) The movement of reactive power consumes transmission resources, which limits the ability to move real power and worsens congestion. (3) The movement of reactive power results in real-power losses. When generators are required to supply excessive amounts of reactive power, their real-power production must be curtailed. These opportunity costs are not currently compensated for in most regions. Current tariffs are based on embedded costs. These embedded-cost tariffs average about $0.51/MWh, equivalent to $1.5 billion annually for the United States as a whole. Although this cost is low when compared with the cost of energy, it still aggregates to a significant amount of money. This report takes a basic look at why the power system requires reactive power (an appendix explains the fundamentals of real and reactive power). The report then examines the various types of generation and transmission resources used to supply reactive power and to control voltage. Finally it discusses how these resources are deployed and paid for in several reliability regions around the country. As the U.S. electricity industry is restructured, the generation, transmission, and system-control equipment and functions that maintain voltages within the appropriate ranges are being deintegrated.

Kirby, B.; Hirst, E.

1997-12-01T23:59:59.000Z

118

Power flow analysis for DC voltage droop controlled DC microgrids  

E-Print Network [OSTI]

loss, such as photovoltaic panels, batteries, fuel cells, LEDs, and electronic loads, DC microgrids sharing and secondary voltage regulation can now be analytically studied, and specialized optimization of the DC microgrid, in term of systematic analysis, protection coordination design, network optimization

Chaudhary, Sanjay

119

La morphologie du pluriel nominal du persan d’après la théorie Whole Word Morphology.  

E-Print Network [OSTI]

??Ce mémoire présente une étude de la morphologie de ce qui est généralement appelé le pluriel nominal du persan (parler de Téhéran) dans le cadre… (more)

Faghiri, Pegah

2010-01-01T23:59:59.000Z

120

Modulated voltage metastable ionization detector  

SciTech Connect (OSTI)

Metastable ionization detectors used for chromatographic analysis usually employa fixed high voltage for the ionization potential. For this reason, the operating range is limited to about three orders of magnitude. By use of the technique disclosed in the instant invention, operating ranges of about nine orders of magnitude are obtained. The output current from a metastable ionization detector (MID) is applied to a modulation voltage circuit. An adjustment is made to balance out the background current, and an output current, above background, is applied to an input of a strip chart recorder. For low level concentrations, i.e., low detected output current, the ionization potential will be at a maximum and the metastable ionization detector will operate at its most sensitive level. When the detected current from the metastable ionization detector increases above a predetermined threshold level, a voltage control circuit is activated which turns on a high voltage transistor which acts to reduce the ionization potential. The ionization potential applied to the metastable ionization detector is then varied so as to maintain the detected signal level constant. The variation in ionization potential is now related to the concentration fo the constituent and a representative amplitude is applied to another input of said strip chart recorder.

Carle, G. C.; Humphry, D. E.; Kojiro, D. R.

1985-08-27T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Onset voltage of corona on coated conductors  

SciTech Connect (OSTI)

This paper is aimed for investigating the effect of surface coating on the positive and negative onset voltages of corona from stressed conductor as a pre-requisite for onset-voltage calculation. The electric field is accurately calculated by the charge simulation technique. The calculated onset voltages agreed satisfactorily with those measured experimentally for bare conductors. The effect of coating-layer thickness and permittivity as well as conductor radius and height on the onset-voltage values is discussed.

Abdel-Salam, M. [Assiut Univ. (Egypt). Electrical Engineering Dept.; Abo-Shal, Y. [SCECO-East, Dammam (Saudi Arabia). Electrical Engineering Div.

1995-12-31T23:59:59.000Z

122

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Broader source: Energy.gov [DOE]

Presentation given by Seeo, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high-voltage solid polymer...

123

Low power, scalable multichannel high voltage controller  

DOE Patents [OSTI]

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

2006-03-14T23:59:59.000Z

124

Low power, scalable multichannel high voltage controller  

DOE Patents [OSTI]

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

2008-03-25T23:59:59.000Z

125

Dynamic Voltage Regulation Using Distributed Energy Resources  

SciTech Connect (OSTI)

Many distributed energy resources (DE) are near load centres and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide ancillary services such as voltage regulation, nonactive power compensation, and power factor correction. A synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Voltage control schemes of the inverter and the synchronous condenser are developed. The experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously, while the dynamic response of the inverter is faster than the synchronous condenser; and that integrated voltage regulation (multiple DE perform voltage regulation) can increase the voltage regulation capability, increase the lifetime of the equipment, and reduce the capital and operation costs.

Xu, Yan [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL

2007-01-01T23:59:59.000Z

126

Spring Creek Project for Ideas, Nature, and the Written Word Call for Nominations: Graduate Student Research and Writing Retreat  

E-Print Network [OSTI]

Spring Creek Project for Ideas, Nature, and the Written Word Call for Nominations: Graduate Student on a collaborative project or two graduate students who each have individual projects are invited to nominate graduate students in the humanities or environmental sciences

Grünwald, Niklaus J.

127

Voltage Vehicles | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:Seadov PtyInformationSEDS data Jump to: navigation, search ToolVoith HydroVoltage

128

Dynamic photorefractivity guided by single-pulse voltage  

SciTech Connect (OSTI)

The dynamic photorefractivity in a cell with photoconducting orienting layers, filled with a nematic liquid crystal (LC) 6CHBT and a mixture of anthraquinone dyes AD1 and AD2, has been investigated. The single-pulse mode, in which the polarity and amplitude of a dc electric field applied to an LC cell are switched for a fixed time interval, has been used. The scheme of dynamic self-diffraction of low-power laser beams was used in the experiment. The dependences of the width and intensity of diffraction pulses on the bias and switching voltages have been investigated. It is established that the width and intensity of the diffraction pulse arising after initial voltage recovery depends also on the switching pulse width. At the optimal width of the control pulse, the diffraction efficiency increases by two orders of magnitude.

Agashkov, A. V., E-mail: agashkov@inel.bas.net.by; Kovalev, A. A. [National Academy of Sciences of Belarus, Institute of Electronics (Belarus); Parka, J. [Military University of Technology, Institute of Applied Physics (Poland)

2008-03-15T23:59:59.000Z

129

Wind Power Plant Voltage Stability Evaluation: Preprint  

SciTech Connect (OSTI)

Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

Muljadi, E.; Zhang, Y. C.

2014-09-01T23:59:59.000Z

130

High voltage load resistor array  

DOE Patents [OSTI]

A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

Lehmann, Monty Ray (Smithfield, VA)

2005-01-18T23:59:59.000Z

131

Group 3: Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect (OSTI)

Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-05-01T23:59:59.000Z

132

High Voltage Electrolyte for Lithium Batteries  

Broader source: Energy.gov (indexed) [DOE]

battery using high voltage high energy cathode materials to enable large-scale, cost competitive production of the next generation of electric-drive vehicles. To...

133

Method to improve reliability of a fuel cell system using low performance cell detection at low power operation  

DOE Patents [OSTI]

A system and method for detecting a low performing cell in a fuel cell stack using measured cell voltages. The method includes determining that the fuel cell stack is running, the stack coolant temperature is above a certain temperature and the stack current density is within a relatively low power range. The method further includes calculating the average cell voltage, and determining whether the difference between the average cell voltage and the minimum cell voltage is greater than a predetermined threshold. If the difference between the average cell voltage and the minimum cell voltage is greater than the predetermined threshold and the minimum cell voltage is less than another predetermined threshold, then the method increments a low performing cell timer. A ratio of the low performing cell timer and a system run timer is calculated to identify a low performing cell.

Choi, Tayoung; Ganapathy, Sriram; Jung, Jaehak; Savage, David R.; Lakshmanan, Balasubramanian; Vecasey, Pamela M.

2013-04-16T23:59:59.000Z

134

The Constant Voltage Transformer (CVT) for Mitigating Effects of Voltage Sags on Industrial Equipment  

E-Print Network [OSTI]

) an increase in loads that use power electronics in some type of power conversion configuration [1][2]. This paper presents applications of the constant-voltage transformer (CVT) for mitigating the effects of electric service voltage sags on industrial...

Ferraro, R. J.; Osborne, R.; Stephens, R.

135

Variable current-voltage TPV device for use in a thermophotovoltaic energy conversion system  

DOE Patents [OSTI]

A front-side or back-side illuminated variable current-voltage thermophotovoltaic device comprises a support substrate; isolation layers disposed on the support substrate; a plurality of cells disposed on the isolation layers, each of the cells including a base layer and an emitter layer; an insulating member disposed between each of the cells configured to isolate each cell from adjacent cells; an ohmic contact configured to connect each cell to another cell in series; and a spectral control device disposed on top of the cells and/or on the bottom surface of the support substrate.

Charache, Greg W. (Clifton Park, NY); Baldasaro, Paul F. (Clifton Park, NY); Campbell, Brian C. (Scotia, NY)

2000-01-01T23:59:59.000Z

136

Voltage Collapse SimulationVoltage Collapse Simulation (Eastern Interconnection(Eastern Interconnection  

E-Print Network [OSTI]

PSERC Voltage Collapse SimulationVoltage Collapse Simulation (Eastern Interconnection(Eastern Interconnection Scenario)Scenario) Simulation Prepared by Dennis J. RaySimulation Prepared by Dennis J. Ray Interconnection based on a series of generator and line outages. An actual voltage collapse may not occur due

137

DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION  

E-Print Network [OSTI]

1 DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION In this paper the design and implementation of a fuzzy logic-based controller is described for regulating the output voltage of a synchronous generator. An automated fuzzy logic-based control strategy is presented

LaMeres, Brock J.

138

Optimal Power Flow Incorporating Voltage Collapse Constraints  

E-Print Network [OSTI]

Optimal Power Flow Incorporating Voltage Collapse Constraints William Rosehart Claudio Ca on the current operating con- ditions is presented. Second, an Optimal Power Flow formulation that incorporates: Voltage Collapse, Optimal Power Flow, Bifur- cations. I. Introduction As open-access market principles

Cañizares, Claudio A.

139

Voltage regulation in linear induction accelerators  

DOE Patents [OSTI]

Improvement in voltage regulation in a Linear Induction Accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance.

Parsons, William M. (Santa Fe, NM)

1992-01-01T23:59:59.000Z

140

Voltage regulation in linear induction accelerators  

DOE Patents [OSTI]

Improvement in voltage regulation in a linear induction accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core is disclosed. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance. 4 figs.

Parsons, W.M.

1992-12-29T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Non-contact current and voltage sensor  

SciTech Connect (OSTI)

A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

2014-03-25T23:59:59.000Z

142

Wide-range voltage modulation  

SciTech Connect (OSTI)

The Superconducting Super Collider`s Medium Energy Booster Abort (MEBA) kicker modulator will supply a current pulse to the abort magnets which deflect the proton beam from the MEB ring into a designated beam stop. The abort kicker will be used extensively during testing of the Low Energy Booster (LEB) and the MEB rings. When the Collider is in full operation, the MEBA kicker modulator will abort the MEB beam in the event of a malfunction during the filling process. The modulator must generate a 14-{mu}s wide pulse with a rise time of less than 1 {mu}s, including the delay and jitter times. It must also be able to deliver a current pulse to the magnet proportional to the beam energy at any time during ramp-up of the accelerator. Tracking the beam energy, which increases from 12 GeV at injection to 200 GeV at extraction, requires the modulator to operate over a wide range of voltages (4 kV to 80 kV). A vacuum spark gap and a thyratron have been chosen for test and evaluation as candidate switches for the abort modulator. Modulator design, switching time delay, jitter and pre-fire data are presented.

Rust, K.R.; Wilson, J.M.

1992-06-01T23:59:59.000Z

143

PH-315 A. La Rosa VOLTAGE-CONTROLLED OSCILLATOR  

E-Print Network [OSTI]

PH-315 A. La Rosa VOLTAGE-CONTROLLED OSCILLATOR 1. PURPOSE: An integrator and a Schmitt Trigger voltage; hence its name "voltage-controlled oscillator." 2. VOLTAGE-CONTROLLED OSCILLATOR Figure 1 shows voltage. An unusual feature of the circuit is its operation using a single positive supply.1 #12;- + 50k V

144

EERE Efficiency Expert Nominated for American Service Award | Department of  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: TopEnergy DOEDealingVehicle1 ClosingAInnovations in Fuel CellMay 30,Energy

145

Electro-optical voltage sensor head  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID)

1998-01-01T23:59:59.000Z

146

Z .Bioelectrochemistry and Bioenergetics 45 1998 316 Time course of transmembrane voltage induced by time-varying electric  

E-Print Network [OSTI]

Z .Bioelectrochemistry and Bioenergetics 45 1998 3­16 Time course of transmembrane voltage induced.rBioelectrochemistry and Bioenergetics 45 1998 3­164 Fig. 1. The model on which the calculations were based. The cell is a sphere

Ljubljana, University of

147

Researchers map atomic movements that trigger voltage fade in...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

map atomic movements that trigger voltage fade in high-energy-density batteries January 22, 2015 Voltage and capacity curves from an LMR-NMC high-energy cathode show voltage fade...

148

Modular high voltage power supply for chemical analysis  

DOE Patents [OSTI]

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2008-07-15T23:59:59.000Z

149

Modular high voltage power supply for chemical analysis  

SciTech Connect (OSTI)

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2010-05-04T23:59:59.000Z

150

Modular high voltage power supply for chemical analysis  

DOE Patents [OSTI]

A high voltage power supply for use in a system such as a microfluidics system, uses a DC--DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC--DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2007-01-09T23:59:59.000Z

151

Electro-optic high voltage sensor  

DOE Patents [OSTI]

A small sized electro-optic voltage sensor capable of accurate measurement of high voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation. A polarization beam displacer separates the input beam into two beams with orthogonal linear polarizations and causes one linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels effect elliptically polarizes the beam as it travels through the crystal. A reflector redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization. The system may include a detector for converting the output beams into electrical signals and a signal processor for determining the voltage based on an analysis of the output beams.

Davidson, James R.; Seifert, Gary D.

2003-09-16T23:59:59.000Z

152

Voltage Management of Networks with Distributed Generation.   

E-Print Network [OSTI]

At present there is much debate about the impacts and benefits of increasing the amount of generation connected to the low voltage areas of the electricity distribution network. The UK government is under political ...

O'Donnell, James

2008-01-01T23:59:59.000Z

153

Low voltage arc formation in railguns  

DOE Patents [OSTI]

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, R.S.

1985-08-05T23:59:59.000Z

154

Low voltage arc formation in railguns  

DOE Patents [OSTI]

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile. 2 figs.

Hawke, R.S.

1987-11-17T23:59:59.000Z

155

Low voltage arc formation in railguns  

DOE Patents [OSTI]

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, Ronald S. (Livermore, CA)

1987-01-01T23:59:59.000Z

156

Group 3: Humidity, Temperature, and Voltage  

Broader source: Energy.gov [DOE]

This PowerPoint presentation, focused on humidity, temperature and voltage testing, was originally presented by John Wohlgemuth at the NREL 2013 PV Module Reliability Workshop on Feb. 26-27, 2013 in Denver, CO. It summarizes the activities of a working group chartered to develop accelerated stress tests that can be used as comparative predictors of module life versus stresses associated with humidity, temperature and voltage.

157

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2013 DOE...

158

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2012 DOE Hydrogen and...

159

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid...  

Broader source: Energy.gov (indexed) [DOE]

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...

160

High voltage overhead long transmission line design and fault analysis.  

E-Print Network [OSTI]

??The goal of this project is to design a reliable high voltage overhead long transmission line that satisfies specific design criteria including voltage regulation, efficiency,… (more)

Elzain, Mohamed Ali

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Australian Academy of Science Consent to Nomination for Fellowship of the Australian Academy of Science  

E-Print Network [OSTI]

July 2012 Australian Academy of Science Consent to Nomination for Fellowship of the Australian Academy of Science I, Prof. Anatoli Kheifets acknowledge that I have been proposed by Prof. Vladimir Bazhanov, FAAS for Ordinary Election to Fellowship of the Australian Academy of Science. I declare that I

Kheifets, Anatoli

162

Formalising the -calculus using Nominal Logic Jesper Bengtson and Joachim Parrow  

E-Print Network [OSTI]

of Information Technology, University of Uppsala, Sweden Abstract. We formalise the pi-calculus using the nominal an implementation in Isabelle/HOL. The purpose is to derive powerful induction rules for the semantics in order. This is a normal strategy for manual proofs about the pi-calculus, but that kind of hand waving has previously been

Flener, Pierre

163

UWMadison Campus Nomination Process for Rhodes, Marshall and Mitchell Scholarships Information for Recommenders  

E-Print Network [OSTI]

UWMadison Campus Nomination Process for Rhodes, Marshall and Mitchell Scholarships Information to the Rhodes Scholarship, Marshall Scholarship, and/or Mitchell Scholarship from UWMadison. These scholarships fund postbaccalaureate study at the University of Oxford (Rhodes), any university in the UK (Marshall

Liblit, Ben

164

A Nominal Filter for Web Search Snippets: Using the Web to Identify Members of Latin  

E-Print Network [OSTI]

A Nominal Filter for Web Search Snippets: Using the Web to Identify Members of Latin America. This paper presents efforts aimed at using Natural Language Engineering (NLE) techniques to solve of three Latin American countries: Uruguay, Argentina and Colombia. An NLE system is under construction

Turner, William

165

arXiv:1003.5447v2[cs.LO]14May2010 Relating Nominal and Higher-order  

E-Print Network [OSTI]

, nominal logic, higher-order abstract syn- tax This work has been supported by INRIA through the "Equipes]. Formalizing speci- fication based on higher-order abstract syntax requires a frame- work with devicesarXiv:1003.5447v2[cs.LO]14May2010 Relating Nominal and Higher-order Abstract Syntax Specifications

Paris-Sud XI, Université de

166

Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics  

SciTech Connect (OSTI)

This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

Liu, E.; Bebic, J.

2008-02-01T23:59:59.000Z

167

A Charge Pump that Generates Negative High Voltage with Variable Voltage , Eugene Ivanova,  

E-Print Network [OSTI]

A Charge Pump that Generates Negative High Voltage with Variable Voltage Gain Jun Zhaob, , Eugene, Massachusetts 02115, U.S.A. Abstract A cross-coupled structure based charge pump that generates negative high. The proposed negative charge pump is designed to deliver 40 uA with a wide supply range from 2.5V to 5.5V using

Ayers, Joseph

168

Distributed Voltage and Current Control of Multi-Terminal High-Voltage Direct  

E-Print Network [OSTI]

}@kth.se.) Abstract: High-voltage direct current (HVDC) is a commonly used technology for long-distance power for multi-terminal HVDC (MTDC) systems is proposed. Under certain conditions on the controller gains factor behind long-distance power transmission. High-voltage direct current (HVDC) is a commonly used

Dimarogonas, Dimos

169

Experimental validation of a high voltage pulse measurement method.  

SciTech Connect (OSTI)

This report describes X-cut lithium niobate's (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps - 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensor's U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

Cular, Stefan; Patel, Nishant Bhupendra; Branch, Darren W.

2013-09-01T23:59:59.000Z

170

Compact high voltage solid state switch  

DOE Patents [OSTI]

A compact, solid state, high voltage switch capable of high conduction current with a high rate of current risetime (high di/dt) that can be used to replace thyratrons in existing and new applications. The switch has multiple thyristors packaged in a single enclosure. Each thyristor has its own gate drive circuit that circuit obtains its energy from the energy that is being switched in the main circuit. The gate drives are triggered with a low voltage, low current pulse isolated by a small inexpensive transformer. The gate circuits can also be triggered with an optical signal, eliminating the trigger transformer altogether. This approach makes it easier to connect many thyristors in series to obtain the hold off voltages of greater than 80 kV.

Glidden, Steven C.

2003-09-23T23:59:59.000Z

171

System Voltage Potential-Induced Degradation Mechanisms in PV Modules and Methods for Test  

SciTech Connect (OSTI)

Over the past decade, degradation and power loss have been observed in PV modules resulting from the stress exerted by system voltage bias. This is due in part to qualification tests and standards that do not adequately evaluate for the durability of modules to the long-term effects of high voltage bias experienced in fielded arrays. High voltage can lead to module degradation by multiple mechanisms. The extent of the voltage bias degradation is linked to the leakage current or culombs passed from the silicon active layer through the encapsulant and glass to the grounded module frame, which can be experimentally determined; however, competing processes make the effect non-linear and history-dependent. Appropriate testing methods and stress levels are described that demonstrate module durability to system voltage potential-induced degradation (PID) mechanisms. This information, along with outdoor testing that is in progress, is used to estimate the acceleration factors needed to evaluate the durability of modules to system voltage stress. Na-rich precipitates are observed on the cell surface after stressing the module to induce PID in damp heat with negative bias applied to the active layer.

Hacke, P.; Terwilliger, K.; Smith, R.; Glick, S.; Pankow, J.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-01-01T23:59:59.000Z

172

System Voltage Potential-Induced Degradation Mechanisms in PV Modules and Methods for Test: Preprint  

SciTech Connect (OSTI)

Over the past decade, degradation and power loss have been observed in PV modules resulting from the stress exerted by system voltage bias. This is due in part to qualification tests and standards that do not adequately evaluate for the durability of modules to the long-term effects of high voltage bias experienced in fielded arrays. High voltage can lead to module degradation by multiple mechanisms. The extent of the voltage bias degradation is linked to the leakage current or coulombs passed from the silicon active layer through the encapsulant and glass to the grounded module frame, which can be experimentally determined; however, competing processes make the effect non-linear and history-dependent. Appropriate testing methods and stress levels are described that demonstrate module durability to system voltage potential-induced degradation (PID) mechanisms. This information, along with outdoor testing that is in progress, is used to estimate the acceleration factors needed to evaluate the durability of modules to system voltage stress. Na-rich precipitates are observed on the cell surface after stressing the module to induce PID in damp heat with negative bias applied to the active layer.

Hacke, P.; Terwilliger, K.; Smith, R.; Glick, S.; Pankow, J.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-07-01T23:59:59.000Z

173

SiGe BiCMOS Topologies for Low-Voltage Millimeter-Wave Voltage Controlled Oscillators and Frequency Dividers  

E-Print Network [OSTI]

SiGe BiCMOS Topologies for Low-Voltage Millimeter-Wave Voltage Controlled Oscillators and Frequency-mail: tod@eecg.toronto.edu Abstract -- BiCMOS topologies for mm-wave voltage- controlled oscillators operation for mm-wave applications. II. BICMOS VOLTAGE-CONTROLLED OSCILLATOR The Colpitts topology

Voinigescu, Sorin Petre

174

Physical simulation study of dynamic voltage instability  

SciTech Connect (OSTI)

This paper presents a physical simulation of the dynamic behavior of voltage instability in an interconnected multimachine environment. The dynamic evolving process leading to eventual voltage collapse, the scenario of the progressive reactive support reduction resulting from the MXL protection relays, the OLTC operation, and the effect of switched-in capacitor banks are examined using physical facilities in the laboratory. The physical simulation results are also compared with digital simulation results. This physical investigation provides a reliable foundation for the effective development of assessment approaches and countermeasures.

Tso, S.K.; Zhu, T.X. [Univ. of Hong Kong (Hong Kong); Zeng, Q.Y. [Electric Power Research Inst., Beijing (China); Lo, K.L. [Univ. of Strathclyde, Glasgow (United Kingdom). Dept. of Electrical and Electrical Engineering

1995-12-31T23:59:59.000Z

175

Voltage-gated Ion Channels and Gating Modifier Toxins William A. Catterall,* Sandrine Cestle,  

E-Print Network [OSTI]

;2 Abstract Voltage-gated sodium, calcium, and potassium channels generate electrical signals required and a pore loop. Their pores are formed by the S5/S6 segments and the pore loop between them and are gated and participate in calcium signaling pathways in nonexcitable cells. Because of their importance in many aspects

Paris-Sud XI, Université de

176

Electro-optic voltage sensor for sensing voltage in an E-field  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID); Renak, Todd W. (Idaho Falls, ID)

1999-01-01T23:59:59.000Z

177

Electro-optic voltage sensor for sensing voltage in an E-field  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages is disclosed. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam`s polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured. 18 figs.

Woods, G.K.; Renak, T.W.

1999-04-06T23:59:59.000Z

178

Group 3: Humidity, Temperature and Voltage (Presentation)  

SciTech Connect (OSTI)

This is a summary of the work of Group 3 of the International PV QA Task Force. Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-09-01T23:59:59.000Z

179

Voltage control on a train system  

DOE Patents [OSTI]

The present invention provides methods for preventing low train voltages and managing interference, thereby improving the efficiency, reliability, and passenger comfort associated with commuter trains. An algorithm implementing neural network technology is used to predict low voltages before they occur. Once voltages are predicted, then multiple trains can be controlled to prevent low voltage events. Further, algorithms for managing inference are presented in the present invention. Different types of interference problems are addressed in the present invention such as "Interference During Acceleration", "Interference Near Station Stops", and "Interference During Delay Recovery." Managing such interference avoids unnecessary brake/acceleration cycles during acceleration, immediately before station stops, and after substantial delays. Algorithms are demonstrated to avoid oscillatory brake/acceleration cycles due to interference and to smooth the trajectories of closely following trains. This is achieved by maintaining sufficient following distances to avoid unnecessary braking/accelerating. These methods generate smooth train trajectories, making for a more comfortable ride, and improve train motor reliability by avoiding unnecessary mode-changes between propulsion and braking. These algorithms can also have a favorable impact on traction power system requirements and energy consumption.

Gordon, Susanna P.; Evans, John A.

2004-01-20T23:59:59.000Z

180

Electro-optic high voltage sensor  

DOE Patents [OSTI]

A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal having at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

Davidson, James R. (Idaho Falls, ID); Seifert, Gary D. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

CSI ELECTIONS 2006-2007 / 2006-2008 We thank you for electing us to work together on the CSI Nominations Committee 2005-06. We  

E-Print Network [OSTI]

Nominations Committee 2005-06. We believe the Nominations Committee has a significant role to play in ensuring of IT for Elections. Nominations Committee 2005-06, CSI Satish Doshi (Chairman) M D Agrawal (Member) Dr Nirmal Jain Conference on IT for Defence-.orce Multiplier 35 Executive Committee (2005-06/2007) 36 CONMICRO 2005

Melbourne, University of

182

Distribution System Voltage Regulation by Distributed Energy Resources  

SciTech Connect (OSTI)

This paper proposes a control method to regulate voltages in 3 phase unbalanced electrical distribution systems. A constrained optimization problem to minimize voltage deviations and maximize distributed energy resource (DER) active power output is solved by harmony search algorithm. IEEE 13 Bus Distribution Test System was modified to test three different cases: a) only voltage regulator controlled system b) only DER controlled system and c) both voltage regulator and DER controlled system. The simulation results show that systems with both voltage regulators and DER control provide better voltage profile.

Ceylan, Oguzhan [ORNL; Liu, Guodong [ORNL; Xu, Yan [ORNL; Tomsovic, Kevin [University of Tennessee, Knoxville (UTK)

2014-01-01T23:59:59.000Z

183

Electrical system architecture having high voltage bus  

DOE Patents [OSTI]

An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

2011-03-22T23:59:59.000Z

184

Reactive Support and Voltage Control Service: Key Issues and Challenges  

E-Print Network [OSTI]

reactive support and voltage control services. Keywords ­ Competitive Electricity Markets, Reactive PowerReactive Support and Voltage Control Service: Key Issues and Challenges George Gross^, Paolo Marannino° and Gianfranco Chicco* ^ Department of Electrical and Computer Engineering, University

Gross, George

185

Low Voltage White Phosphorescent OLED Achievements  

Broader source: Energy.gov [DOE]

Universal Display Corporation (UDC) and its research partners at Princeton University and the University of Southern California have succeeded in developing a white phosphorescent OLED (PHOLED™) that achieved a record efficiency of 20 lumens per watt. This achievement is the result of the team's collaborative efforts to increase the efficiency of PHOLED lighting by focusing on two critical factors: lowering the drive voltages and increasing the amount of light extracted.

186

High Voltage Electrolyte for Lithium Batteries  

Broader source: Energy.gov (indexed) [DOE]

5.0E-04 1.0E-03 2 2.2 2.4 2.6 2.8 Voltage (V) dQdV (AhV) 1 st Charge 1.2M LiPF 6 ECEMC 37 1 st Charge 1.0M LiPF 6 TMS1NM3 55 with 2% and 4% VC 1 st Charge 1.0M LiPF 6 TMS...

187

Electro-optic voltage sensor head  

DOE Patents [OSTI]

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers.

Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Woods, Gregory K. (Cornelius, OR)

1999-01-01T23:59:59.000Z

188

Electro-optic voltage sensor head  

DOE Patents [OSTI]

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers. 6 figs.

Crawford, T.M.; Davidson, J.R.; Woods, G.K.

1999-08-17T23:59:59.000Z

189

Electrostatically screened, voltage-controlled electrostatic chuck  

DOE Patents [OSTI]

Employing an electrostatically screened, voltage-controlled electrostatic chuck particularly suited for holding wafers and masks in sub-atmospheric operations will significantly reduce the likelihood of contaminant deposition on the substrates. The electrostatic chuck includes (1) an insulator block having a outer perimeter and a planar surface adapted to support the substrate and comprising at least one electrode (typically a pair of electrodes that are embedded in the insulator block), (2) a source of voltage that is connected to the at least one electrode, (3) a support base to which the insulator block is attached, and (4) a primary electrostatic shield ring member that is positioned around the outer perimeter of the insulator block. The electrostatic chuck permits control of the voltage of the lithographic substrate; in addition, it provides electrostatic shielding of the stray electric fields issuing from the sides of the electrostatic chuck. The shielding effectively prevents electric fields from wrapping around to the upper or front surface of the substrate, thereby eliminating electrostatic particle deposition.

Klebanoff, Leonard Elliott (San Ramon, CA)

2001-01-01T23:59:59.000Z

190

Analysis and design of an electronic voltage ratchet  

E-Print Network [OSTI]

and decay. Impulse voltages are produced through the discharging of 0, capacitor into a shaping network consisting of resistors and a. capacitor as is shown in Figure 2. 9. The operation of the impulse generator is as follows. Capacitor Ci is charged from... voltage shaping network. as possible in order to reduce oscillations in the wavefront and wavetail portions of the impulse voltage [1). The impulse voltage generator requires a, highly charged capacitor or bank of capacitors. Capacitors may be charged...

Menendez, Jorge Carlos

2012-06-07T23:59:59.000Z

191

Selective compensation of voltage harmonics in grid-connected microgrids  

E-Print Network [OSTI]

1 Selective compensation of voltage harmonics in grid-connected microgrids Mehdi Savaghebia , Juan is proposed for selective compensation of main voltage harmonics in a grid- connected microgrid. The aim level. Keywords Distributed Generator (DG); microgrid; grid-connected; voltage harmonics compensation. 1

Vasquez, Juan Carlos

192

Structural Optimization of High Voltage Transmission Line Towers considering  

E-Print Network [OSTI]

Structural Optimization of High Voltage Transmission Line Towers considering Continuum and Discrete/or to common designs largely repeated (e.g. automotive compo- nents), and high voltage transmission towers can than conventional designs of high voltage transmission line towers. The optimization model proposed

Colominas, Ignasi

193

LM2907LM2917FrequencytoVoltageConverter February 1995  

E-Print Network [OSTI]

TL H 7942 LM2907LM2917FrequencytoVoltageConverter February 1995 LM2907 LM2917 Frequency to Voltage Converter General Description The LM2907 LM2917 series are monolithic frequency to voltage converters doubling for low ripple full input protection in two versions (LM2907-8 LM2917-8) and its output swings

Wedeward, Kevin

194

Characterized ideal LC circuit Charge, current and voltage vary sinusoidally  

E-Print Network [OSTI]

resistance to LC circuit Oscillations become damped Charge, current and voltage still vary sinusoidally Oscillations Draw phasors for voltages of R, C and L at same time t Orient VR, VL, & VC phasors relativeReview Characterized ideal LC circuit Charge, current and voltage vary sinusoidally Added

Bertulani, Carlos A. - Department of Physics and Astronomy, Texas A&M University

195

Accurately measuring current-voltage characteristics of tunnel diodes  

E-Print Network [OSTI]

of the bias voltage range of oscillations in the I–V curve.and the bias voltage range of oscillation in the I–V curve.or to know the exact voltage range of oscillation in the I–V

Bao, Mingqiang; Wang, Kang L

2006-01-01T23:59:59.000Z

196

DCS1800/WCDMA ADAPTIVE VOLTAGE-CONTROLLED OSCILLATOR  

E-Print Network [OSTI]

DCS1800/WCDMA ADAPTIVE VOLTAGE-CONTROLLED OSCILLATOR Aleksandar Tasiü, Wouter A. Serdijn and John R, an adaptive 2G/3G voltage-controlled oscillator (VCO) is described in this paper. For the DCS1800 operation with this reasoning, an adaptive 2G/3G voltage- controlled oscillator, meant for a dual-standard adaptive front

Serdijn, Wouter A.

197

System for increasing corona inception voltage of insulating oils  

DOE Patents [OSTI]

The Corona Inception Voltage of insulating oils is increased by repetitive cycles of prestressing the oil with a voltage greater than the corona inception voltage, and either simultaneously or serially removing byproducts of corona by evacuation and heating the oil. 5 figs.

Rohwein, G.J.

1998-05-19T23:59:59.000Z

198

Price of Cameron, LA Natural Gas LNG Imports (Nominal Dollars per Thousand  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2007 10,998 9,933 10,998 10,643 10,998through 1996)DecadeYear Jan670,174per(Nominal Dollars per

199

Price of Cameron, LA Natural Gas LNG Imports from Qatar (Nominal Dollars  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2007 10,998 9,933 10,998 10,643 10,998through 1996)DecadeYear Jan670,174per(Nominal Dollars perper Thousand

200

Price of Cove Point, MD Natural Gas LNG Imports from Egypt (Nominal Dollars  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2007 10,998 9,933 10,998 10,643 10,998through 1996)DecadeYear Jan670,174per(NominalThousand Cubicper

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Nomination & Selection Guidelines | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched5 Industrial CarbonArticlesHuman Resources HumanOffice ofNP User TheNewsNomination

202

Nominations open for $250,000 Multimedia Clean Energy prizes | OpenEI  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth's HeatMexico:Community Nominations open for $250,000 Multimedia Clean Energy

203

Voltage-matched multijunction solar cell architectures for integrating PV  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500IIVasudhaSurface. | EMSLVisualizing

204

Electrochemical Characterization of Voltage Fade in LMR-NMC cells |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE: ECM SummaryandandElectrosynthesis withDepartment of

205

Pattern recognition monitoring of PEM fuel cell  

DOE Patents [OSTI]

The CO-concentration in the H.sub.2 feed stream to a PEM fuel cell stack is monitored by measuring current and voltage behavior patterns from an auxiliary cell attached to the end of the stack. The auxiliary cell is connected to the same oxygen and hydrogen feed manifolds that supply the stack, and discharges through a constant load. Pattern recognition software compares the current and voltage patterns from the auxiliary cell to current and voltage signature determined from a reference cell similar to the auxiliary cell and operated under controlled conditions over a wide range of CO-concentrations in the H.sub.2 fuel stream.

Meltser, Mark Alexander (Pittsford, NY)

1999-01-01T23:59:59.000Z

206

Pattern recognition monitoring of PEM fuel cell  

DOE Patents [OSTI]

The CO-concentration in the H{sub 2} feed stream to a PEM fuel cell stack is monitored by measuring current and voltage behavior patterns from an auxiliary cell attached to the end of the stack. The auxiliary cell is connected to the same oxygen and hydrogen feed manifolds that supply the stack, and discharges through a constant load. Pattern recognition software compares the current and voltage patterns from the auxiliary cell to current and voltage signature determined from a reference cell similar to the auxiliary cell and operated under controlled conditions over a wide range of CO-concentrations in the H{sub 2} fuel stream. 4 figs.

Meltser, M.A.

1999-08-31T23:59:59.000Z

207

Method of Controlling Corona Effects and Breakdown Voltage of Small Air Gaps Stressed by Impulse Voltages  

E-Print Network [OSTI]

This paper investigates the influence of a resistor on the dielectric behavior of an air gap. The resistor is connected in series with the air gap and the latter is stressed by impulse voltage. Air gap arrangements of different geometry with either the rod or the plate grounded are stressed with impulse voltages of both positive and negative polarity. The resistor is connected in series with the air gap in the return circuit connecting the gap with the impulse generator. The method followed involves the investigation of the graphs of the charging time concerning the air gaps capacitances, in connection to the value of the resistor, the geometry of the gap, the effect of grounding and the polarity effect. It is determined that the charging time of the air gap increases, as the value of the resistor increases. It is also determined that the peak voltage value of the fully charged air gap decreases as the value of the resistor increases. The results of the mathematical and simulation analysis are compared with the results of the oscillograms taken from experimental work. In addition and consequently to the above results it is concluded from the experimental work that the in series connection of the resistor in the circuit has significant influence on corona pulses (partial discharges) occurring in the gap and on the breakdown voltage of the gap. A new method of controlling the corona effects and consequently the breakdown voltage of small air gaps stressed by impulse voltage of short duration in connection to the ground effect and the polarity effect has arisen. Furthermore through mathematical analysis of the charging graphs obtained from simulation and experimental oscillograms there was a calculation of the values of the capacitance of the air gaps in relation to their geometry and the results were compared to the values calculated with mathematical analysis.

Athanasios Maglaras; Trifon Kousiouris; Frangiskos Topalis; Dimitrios Katsaros; Leandros A. Maglaras; Konstantina Giannakopoulou

2014-10-15T23:59:59.000Z

208

Transient recovery voltage considerations in the application of medium voltage circuit breakers  

SciTech Connect (OSTI)

Medium Voltage Circuit Breakers can fail to interrupt 3-phase fault currents when power systems have Transient Recovery Voltage (TRV) characteristics which exceed the rating of the circuit breaker. This paper examines the application of 13.8kV generation and load switchgear for an oil refinery in which circuit parameters as originally designed would have exceeded the 13.8kV circuit breakers TRV ratings had corrective measures not been taken. This paper illustrates this case and discusses the basis of TRV, how TRV is assessed, and alternative actions taken to bring circuits to within the 13.8 kV circuit breaker ratings.

Swindler, D.L.; Schwartz, P.; Hamer, P.S.; Lambert, S.R.

1995-12-31T23:59:59.000Z

209

Dependence of Band Offset and Open-Circuit Voltage on the Interfacial Interaction between TiO2 and Carboxylated Polythiophenes  

E-Print Network [OSTI]

the open-circuit voltage. An attractive approach for making low-cost photovoltaic (PV) cells is to use bulk, 2005 The interface of planar TiO2/polymer photovoltaic cells was modified with two carboxylated to titania surfaces in photovoltaic cells. If the density of attachment groups is just enough to attach

McGehee, Michael

210

Safe epoxy encapsulant for high voltage magnetics  

SciTech Connect (OSTI)

This paper describes the use of Formula 456, an aliphatic amine cured epoxy for impregnating coils and high voltage transformers. Sandia has evaluated a number of MDA-free epoxy encapsulants which relied on either anhydride or other aromatic amine curing agents. The use of aliphatic amine curing agents was more recently evaluated and has resulted in the definition of Formula 456 resin. Methylene dianiline (MDA) has been used for more than 20 years as the curing agent for various epoxy formulations throughout the Department of Energy and much of industry. Sandia National Laboratories began the process of replacing MDA with other formulations because of regulations imposed by OSHA on the use of MDA. OSHA has regulated MDA because it is a suspect carcinogen. Typically the elimination of OSHA-regulated materials provides a rare opportunity to qualify new formulations in a range of demanding applications. It was important to take full advantage of that opportunity, although the associated materials qualification effort was costly. Small high voltage transformers are one of those demanding applications. The successful implementation of the new formulation for high reliability transformers will be described. The test results that demonstrate the parts are qualified for use in DOE weapon systems will be presented.

Sanchez, R.O.; Archer, W.E.

1998-01-01T23:59:59.000Z

211

Effect of intracellular diffusion on current-voltage curves in potassium channels  

E-Print Network [OSTI]

We study the effect of intracellular ion diffusion on ionic currents permeating through the cell membrane. Ion flux across the cell membrane is mediated by special proteins forming specific channels. The structure of potassium channels have been widely studied in recent years with remarkable results: very precise measurements of the true current across a single channel are now available. Nevertheless, a complete understanding of the behavior of the channel is still lacking, though molecular dynamics and kinetic models have provided partial insights. In this paper we demonstrate, by analyzing the KcsA current-voltage currents via a suitable lattice model, that intracellular diffusion plays a crucial role in the permeation phenomenon. The interplay between the selectivity filter behavior and the ion diffusion in the intracellular side allows a full explanation of the current-voltage curves.

Andreucci, D; Cirillo, E N M; Marconi, S

2015-01-01T23:59:59.000Z

212

Chemical detection and laser wavelength stabilization employing spectroscopic absorption via laser compliance voltage sensing  

DOE Patents [OSTI]

Systems and methods are disclosed that provide a direct indication of the presence and concentration of an analyte within the external cavity of a laser device that employ the compliance voltage across the laser device. The systems can provide stabilization of the laser wavelength. The systems and methods can obviate the need for an external optical detector, an external gas cell, or other sensing region and reduce the complexity and size of the sensing configuration.

Taubman, Matthew S; Phillips, Mark C

2014-03-18T23:59:59.000Z

213

Satellite power system (SPS). Rectenna siting: availability and distribution of nominally eligible sites  

SciTech Connect (OSTI)

Siting of 60 ground receiving stations (rectennas) for the SPS may pose a problem due to the large area per rectenna (15,000 hectares, 38,000 acres) and numerous siting constraints. This study analyzes areas potentially eligible for rectenna sites by mapping, at a national scale, those conditions which would preclude rectenna construction. These exclusion variables which reflect restricted lands, topography, safety, national policy and electromagnetic (microwave) effects, have been computer encoded and tabulated. Subsequent analysis of the nine electric power planning regions that make up the contiguous states indicate an apparently adequate number of nominally eligible sites in all regions in comparison to projected electrical generation. Eligibility in this context means only that areas were not excluded in this national level analysis; more detailed investigation may reveal purely local constraints or smaller scale exclusions. A second major qualification relates to small isolated eligible areas. Eliminating individual eligible clusters with less than nine times the area of one rectenna eliminates much of the Eastern US; a four-to-one adjacent eligible area test poses no such problem. An independant study of the placement of 60 nominal sites in relation to projected load centers reveals that, even with modest transmission distances, the supply of eligible areas is not a key constraint, except perhaps in the Mid-Atlantic (Electric Reliability) Council Region. Even when several less critical (potential) exclusions are considered, more than 19% of the US is eligible; every region except Mid-Atlantic has at least 50 times an many eligible sites as are required.

Not Available

1980-11-01T23:59:59.000Z

214

Design and applications of a flicker voltage generator  

SciTech Connect (OSTI)

In this paper, a 200W flicker voltage generator is made by using microcomputers and linear amplification circuits. The modulation amplitudes and frequencies based on the UIE {Delta}V{sub 10} evaluation can be arbitrarily assigned by software with high accuracy. The flicker voltage signals measured at the customer side also can be re-generated. Some applications, such as evaluating the effects of flicker voltage on incandescent and compact fluorescent lamps (CFLs), are also made. From experimental tests by use of the flicker voltage generator, the properties of some compact fluorescent lamps and incandescent lamps are compared. Those properties describe the relation between input voltage variation and output flux of lamps, such that there is direct description of influences of flicker voltages on lamps.

Chang, W.N.; Wu, C.J. [National Taiwan Inst. of Tech., Peitow-Taipei (Taiwan, Province of China). Dept. of Electrical Engineering

1995-12-31T23:59:59.000Z

215

Sequential circuit design for radiation hardened multiple voltage integrated circuits  

DOE Patents [OSTI]

The present invention includes a radiation hardened sequential circuit, such as a bistable circuit, flip-flop or other suitable design that presents substantial immunity to ionizing radiation while simultaneously maintaining a low operating voltage. In one embodiment, the circuit includes a plurality of logic elements that operate on relatively low voltage, and a master and slave latches each having storage elements that operate on a relatively high voltage.

Clark, Lawrence T. (Phoenix, AZ); McIver, III, John K. (Albuquerque, NM)

2009-11-24T23:59:59.000Z

216

Voltage controlled MESFET pulse shape generator  

SciTech Connect (OSTI)

A programmable pulse shape generator capable of producing pulse shapes for Nova and Beamlet has been designed and simulated using the circuit code SPICE. The design utilizes power MESFETS, which are commonly used in microwave amplifiers. The pulse shape is varied by setting a bias voltage on each in a chain of MESFETS with a 200 ps temporal resolution. The electrical pulse then drives an integrated electro-optic modulator similar to what is on Beamlet. Pulse shapes 22 and 25, used on Nova, have been generated by this design. There is no fundamental barrier to making such a pulse generator for use on the National Ignition Facility. In fact, the longer time scales on the NIF pulse will ease the high speed requirements of the pulse shape generator allowing the use of less expensive components. The next step will be to build a prototype circuit for initial testing on Beamlet and Nova.

Burkhart, S.C.

1994-10-26T23:59:59.000Z

217

Method for voltage-gated protein fractionation  

DOE Patents [OSTI]

We report unique findings on the voltage dependence of protein exclusion from the pores of nanoporous polymer exclusion membranes. The pores are small enough that proteins are excluded from passage with low applied electric fields, but increasing the field enables proteins to pass through. The requisite field necessary for a change in exclusion is protein-specific with a correlation to protein size. The field-dependence of exclusion is important to consider for preconcentration applications. The ability to selectively gate proteins at exclusion membranes is also a promising means for manipulating and characterizing proteins. We show that field-gated exclusion can be used to selectively remove proteins from a mixture, or to selectively trap protein at one exclusion membrane in a series.

Hatch, Anson (Tracy, CA); Singh, Anup K. (Danville, CA)

2012-04-24T23:59:59.000Z

218

High Temperature, High Voltage Fully Integrated Gate Driver Circuit  

Broader source: Energy.gov (indexed) [DOE]

driver circuit, 5-V on- chip voltage regulator, short-circuit protection, undervoltage lockout, bootstrap capacitor, dead time controller and temperature sensor * 0.8-micron,...

219

Nanoscale Morphological and Chemical Changes of High Voltage...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Nanoscale Morphological and Chemical Changes of High Voltage Lithium-Manganese Rich NMC Composite Cathodes with Cycling Friday, August 29, 2014 Renewable energy is critical for the...

220

active capacitive voltage: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Khoman 5 Discrete Steps in the Capacitance-Voltage Characteristics of GaInNGaN Light Emitting Diode Structures Materials Science Websites Summary: Discrete Steps in the...

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

High Voltage Electrolytes for Li-ion Batteries  

Broader source: Energy.gov (indexed) [DOE]

or otherwise restricted information High Voltage Electrolytes for Li-ion Batteries Vehicle Technologies Program 2 Overview * Start: Sep 2008 * End: Sep 2011 * 20 %...

222

Triple voltage dc-to-dc converter and method  

DOE Patents [OSTI]

A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

Su, Gui-Jia (Knoxville, TN)

2008-08-05T23:59:59.000Z

223

Vehicle Technologies Office Merit Review 2014: The Voltage Fade Project, A New Paradigm for Applied Battery Research  

Broader source: Energy.gov [DOE]

Presentation given by the Department of Energy's Energy Storage area at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about a new approach to the challenge of voltage fade in batteries for plug-in electric vehicles.

224

Down-State Model of the Voltage-Sensing Domain of a Potassium Channel Eric V. Schow,  

E-Print Network [OSTI]

traveling along nerve cells are propagated via action potentials generated by sodium and potassium ionsDown-State Model of the Voltage-Sensing Domain of a Potassium Channel Eric V. Schow, J. Alfredo changes upon membrane depolarization, from a down state when the channel is at rest to an up state, all

White, Stephen

225

Novel Nonflammable Electrolytes for Secondary Magnesium Batteries and High Voltage Electrolytes for Electrochemcial Supercapacitors  

SciTech Connect (OSTI)

Magnesium has been used successfully in primary batteries, but its use in rechargeable cells has been stymied by the lack of suitable non-aqueous electrolyte that can conduct Mg+2 species, combined with poor stripping and plating properties. The development of a suitable cathode material for rechargeable magnesium batteries has also been a roadblock, but a nonflammable electrolyte is key. Likewise, the development of safe high voltage electrochemical supercapaitors has been stymied by the use of flammable solvents in the liquid electrolyte; to wit, acetonitrile. The purpose of the research conducted in this effort was to identify useful compositions of magnesium salts and polyphosphate solvents that would enable magnesium ions to be cycled within a secondary battery design. The polyphosphate solvents would provide the solvent for the magnesium salts while preventing the electrolyte from being flammable. This would enable these novel electrolytes to be considered as an alternative to THF-based electrolytes. In addition, we explored several of these solvents together with lithium slats for use as high voltage electrolytes for carbon-based electrochemical supercapacitors. The research was successful in that: 1) Magnesium imide dissolved in a phosphate ester solvent that contains a halogented phosphate ester appears to be the preferred electrolyte for a rechargeable Mg cell. 2) A combination of B-doped CNTs and vanadium phosphate appear to be the cathode of choice for a rechargeable Mg cell by virtue of higher voltage and better reversibility. 3) Magnesium alloys appear to perform better than pure magnesium when used in combination with the novel polyphosphate electrolytes. Also, this effort has established that Phoenix Innovationâ??s family of phosphonate/phosphate electrolytes together with specific lithium slats can be used in supercapacitor systems at voltages of greater than 10V.

Dr. Brian Dixon

2008-12-30T23:59:59.000Z

226

Simple Method Quantifies Recombination Pathways in Solar Cells (Fact Sheet)  

SciTech Connect (OSTI)

NREL's analytic equation uses open-circuit voltage data to determine how much recombination occurs via different channels in a solar cell.

Not Available

2013-09-01T23:59:59.000Z

227

Local Dynamic Reactive Power for Correction of System Voltage Problems  

SciTech Connect (OSTI)

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

Kueck, John D [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Xu, Yan [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Adhikari, Sarina [ORNL; Irminger, Philip [ORNL

2008-12-01T23:59:59.000Z

228

Posted on April 4, 2014 St. Francis Xavier University intends to nominate an exceptional individual for the Tier 2 Canada  

E-Print Network [OSTI]

for the Tier 2 Canada Research Chair in Bioinformatics. The CRC in Bioinformatics will be located students and to mentor future researchers. The Canada Research Chair will be expected to contribute article of the Collective Agreement. The nomination will be at the Tier 2 level of Canada Research Chair

229

The Long-Run Relationship between Money, Nominal GDP, and the Price Level in Venezuela: 1950 to 1996  

E-Print Network [OSTI]

that structural breaks may be important. Since the economy depends heavily on oil revenue, oil price shocks haveThe Long-Run Relationship between Money, Nominal GDP, and the Price Level in Venezuela: 1950 and the price level in the Venezuelan economy. We apply time-series econometric techniques to annual data

Ahmad, Sajjad

230

NOMINATIONS INVITED The Executive Director of the Karl W. Ber Solar Energy Medal of Merit Trust, Prof. Michael T. Klein  

E-Print Network [OSTI]

NOMINATIONS INVITED · The Executive Director of the Karl W. Böer Solar Energy Medal of Merit Trust will be awarded to an individual who has made significant pioneering contributions in solar energy, wind energy to the fields of solar energy, wind energy, or other forms of renewable energy in other ways. PANEL OF JUDGES

Firestone, Jeremy

231

Keys, Nominals, and Concrete Domains Carsten Lutz 1 Carlos Areces 2 Ian Horrocks 3 Ulrike Sattler 1  

E-Print Network [OSTI]

Keys, Nominals, and Concrete Domains Carsten Lutz 1 Carlos Areces 2 Ian Horrocks 3 Ulrike Sattler 1 on an abstract, logical level with an interface to ``concrete'' domains such as numbers and strings. We propose combine powerful logical languages with an interface to concrete do­ mains (e.g., integers, reals, strings

Lutz, Carsten

232

Measurement of high voltage using Rutherford backscattering spectrometry  

E-Print Network [OSTI]

A novel variation of Rutherford Backscattering Spectrometry (RBS) has been utilized to measure a high voltage collected on an aluminum target by Direct Energy Conversion. The maximum high voltage on the target was measured to be 97.5 kV +/- 2 k...

Abrego, Celestino Pete

2007-04-25T23:59:59.000Z

233

A LOW-VOLTAGE TEMPERATURE-STABLE MICROMECHANICAL PIEZOELECTRIC OSCILLATOR  

E-Print Network [OSTI]

A LOW-VOLTAGE TEMPERATURE-STABLE MICROMECHANICAL PIEZOELECTRIC OSCILLATOR Reza Abdolvand, Hossein polarization voltages (5-20V) for operation, which complicates the design of the oscillator circuit in today reference oscillator that utilizes a temperature-stable thin- film piezoelectric-on-silicon resonator

Ayazi, Farrokh

234

REFINED RFP LOOP VOLTAGE CALCULATION J.C. Sprott  

E-Print Network [OSTI]

is the stored magnetic energy, Up is the plasma energy, and 'E is the global energy confinement time, which-of-merit for RFP devices is the loop voltage. Low loop voltage implies high plasma temperature and long energy is smallest if the loop is as close to the outside of the shell and as far from the primary windings

Sprott, Julien Clinton

235

LOW VOLTAGE ANALOG CIRCUITS USING STANDARD CMOS TECHNOLOGY  

E-Print Network [OSTI]

LOW VOLTAGE ANALOG CIRCUITS USING STANDARD CMOS TECHNOLOGY Phillip E. Allen, Benjamin J. Blalock, and Gabriel A. Rincon School of Electrical and Computer Engineering Georgia Institute of Technology Atlanta supply voltages in CMOS integrated circuits. As the channel lengths of CMOS technology decrease

Rincon-Mora, Gabriel A.

236

Power Grid Voltage Integrity Verification Department of ECE  

E-Print Network [OSTI]

Power Grid Voltage Integrity Verification Maha Nizam Department of ECE University of Toronto devgan@magma-da.com ABSTRACT Full-chip verification requires one to check if the power grid is safe, i.e., if the voltage drop on the grid does not exceed a cer- tain threshold. The traditional simulation-based solution

Najm, Farid N.

237

AUSTRALIAN ACADEMY OF SCIENCE-IN-CONFIDENCE The closing date for nomination of a Candidate for Ordinary Election is 31 July each year  

E-Print Network [OSTI]

AUSTRALIAN ACADEMY OF SCIENCE-IN-CONFIDENCE The closing date for nomination of a Candidate for Ordinary Election is 31 July each year Page 1 Certificate revision June 2014 AUSTRALIAN ACADEMY OF SCIENCE will not be circulated by the candidate #12;AUSTRALIAN ACADEMY OF SCIENCE-IN-CONFIDENCE The closing date for nomination

Kheifets, Anatoli

238

Living and Working Safely Around High-Voltage Power Lines.  

SciTech Connect (OSTI)

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

United States. Bonneville Power Administration.

2001-06-01T23:59:59.000Z

239

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1996-01-01T23:59:59.000Z

240

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

Shimer, D.W.; Lange, A.C.

1996-10-15T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Bonfire-safe low-voltage detonator  

DOE Patents [OSTI]

A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half.

Lieberman, Morton L. (Albuquerque, NM)

1990-01-01T23:59:59.000Z

242

Bonfire-safe low-voltage detonator  

DOE Patents [OSTI]

A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half. 2 figs.

Lieberman, M.L.

1988-07-01T23:59:59.000Z

243

High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

Shimer, D.W.; Lange, A.C.

1995-05-23T23:59:59.000Z

244

High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1995-01-01T23:59:59.000Z

245

Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis  

E-Print Network [OSTI]

Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis Claudio A. Ca|Thispaper describesseveralapplica- tions of optimization for voltage stability analysis VSA of power systems. Voltage stability prob

Cañizares, Claudio A.

246

Electro-optic voltage sensor with Multiple Beam Splitting  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID)

2000-01-01T23:59:59.000Z

247

Electro-optic voltage sensor with beam splitting  

DOE Patents [OSTI]

The invention is a miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware typically found in the prior art. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

248

Optically triggered high voltage switch network and method for switching a high voltage  

DOE Patents [OSTI]

An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

1993-01-19T23:59:59.000Z

249

Laser beam apparatus and method for analyzing solar cells  

DOE Patents [OSTI]

A laser beam apparatus and method for analyzing, inter alia, the current versus voltage curve at the point of illumination on a solar cell and the open circuit voltage of a solar cell. The apparatus incorporates a lock-in amplifier, and a laser beam light chopper which permits the measurement of the AC current of the solar cell at an applied DC voltage at the position on the solar cell where the cell is illuminated and a feedback scheme which permits the direct scanning measurements of the open circuit voltage. The accuracy of the measurement is a function of the intensity and wavelength of the laser light with respect to the intensity and wavelength distribution of sunlight and the percentage the dark current is at the open circuit voltage to the short circuit current of the solar cell.

Staebler, David L. (Lawrenceville, NJ)

1980-01-01T23:59:59.000Z

250

Fabrication and transmission measurements of liquid crystal cells  

E-Print Network [OSTI]

between two transparent conducting glass plates. Because of the anisotropic properties of the liquid crystals, their orientation with respect to the polarization of the incident light can be controlled by applying sui. table voltages to the cell. LC... coeffi- cients of the dye molecules with respect to the polarization of the incident light, the transmission can be controlled with the applica- tion of voltage. With no voltage applied to the cell, the dye molecules are aligned...

Yoon, Dae Won

1984-01-01T23:59:59.000Z

251

A capacitor-less low drop-out voltage regulator with fast transient response  

E-Print Network [OSTI]

. Most systems incorporate several voltage regulators which supply various subsystems and provide isolation among such subsystems. Low dropout (LDO) voltage regulators are generally used to supply low voltage, low noise analog circuitry. Each LDO...

Milliken, Robert Jon

2006-04-12T23:59:59.000Z

252

A Multiattribute Utility Analysis of Sites Nominated For Characterization For the First Radioactive Waste Repository- A Decision Aiding Methodology  

Broader source: Energy.gov [DOE]

In December 1984, the Department of Energy (DOE) published draft environmental assessments (EAs) to support the proposed nomination of five sites and the recommendation of three sites for characterization for the first radioactive-waste repository. A chapter common to all the draft EAs (Chapter 7) presented rankings of the five sites against the postclosure and the preclosure technical siting guidelines. To determine which three sites appeared most favorable for recommendation for characterization, three simple quantitative methods were used to aggregate the rankings assigned to each site for the various technical guidelines. In response to numerous comments on the methods, the DOE has undertaken a formal application of one of them (hereafter referred to as the decision-aiding methodology) for the purpose of obtaining a more rigorous evaluation of the nominated sites.

253

Membrane Purification Cell for Aluminum Recycling  

SciTech Connect (OSTI)

Recycling mixed aluminum scrap usually requires adding primary aluminum to the scrap stream as a diluent to reduce the concentration of non-aluminum constituents used in aluminum alloys. Since primary aluminum production requires approximately 10 times more energy than melting scrap, the bulk of the energy and carbon dioxide emissions for recycling are associated with using primary aluminum as a diluent. Eliminating the need for using primary aluminum as a diluent would dramatically reduce energy requirements, decrease carbon dioxide emissions, and increase scrap utilization in recycling. Electrorefining can be used to extract pure aluminum from mixed scrap. Some example applications include producing primary grade aluminum from specific scrap streams such as consumer packaging and mixed alloy saw chips, and recycling multi-alloy products such as brazing sheet. Electrorefining can also be used to extract valuable alloying elements such as Li from Al-Li mixed scrap. This project was aimed at developing an electrorefining process for purifying aluminum to reduce energy consumption and emissions by 75% compared to conventional technology. An electrolytic molten aluminum purification process, utilizing a horizontal membrane cell anode, was designed, constructed, operated and validated. The electrorefining technology could also be used to produce ultra-high purity aluminum for advanced materials applications. The technical objectives for this project were to: - Validate the membrane cell concept with a lab-scale electrorefining cell; - Determine if previously identified voltage increase issue for chloride electrolytes holds for a fluoride-based electrolyte system; - Assess the probability that voltage change issues can be solved; and - Conduct a market and economic analysis to assess commercial feasibility. The process was tested using three different binary alloy compositions (Al-2.0 wt.% Cu, Al-4.7 wt.% Si, Al-0.6 wt.% Fe) and a brazing sheet scrap composition (Al-2.8 wt.% Si-0.7 wt.% Fe-0.8 wt.% Mn),. Purification factors (defined as the initial impurity concentration divided by the final impurity concentration) of greater than 20 were achieved for silicon, iron, copper, and manganese. Cell performance was measured using its current and voltage characteristics and composition analysis of the anode, cathode, and electrolytes. The various cells were autopsied as part of the study. Three electrolyte systems tested were: LiCl-10 wt. % AlCl3, LiCl-10 wt. % AlCl3-5 wt.% AlF3 and LiF-10 wt.% AlF3. An extended four-day run with the LiCl-10 wt.% AlCl3-5 wt.% AlF3 electrolyte system was stable for the entire duration of the experiment, running at energy requirements about one third of the Hoopes and the conventional Hall-Heroult process. Three different anode membranes were investigated with respect to their purification performance and survivability: a woven graphite cloth with 0.05 cm nominal thickness & > 90 % porosity, a drilled rigid membrane with nominal porosity of 33%, and another drilled rigid graphite membrane with increased thickness. The latter rigid drilled graphite was selected as the most promising membrane design. The economic viability of the membrane cell to purify scrap is sensitive to primary & scrap aluminum prices, and the cost of electricity. In particular, it is sensitive to the differential between scrap and primary aluminum price which is highly variable and dependent on the scrap source. In order to be economically viable, any scrap post-processing technology in the U.S. market must have a total operating cost well below the scrap price differential of $0.20-$0.40 per lb to the London Metal Exchange (LME), a margin of 65%-85% of the LME price. The cost to operate the membrane cell is estimated to be < $0.24/lb of purified aluminum. The energy cost is estimated to be $0.05/lb of purified aluminum with the remaining costs being repair and maintenance, electrolyte, labor, taxes and depreciation. The bench-scale work on membrane purification cell process has demonstrated technological advantages and subs

David DeYoung; James Wiswall; Cong Wang

2011-11-29T23:59:59.000Z

254

A Comparison of High-Voltage Switches  

SciTech Connect (OSTI)

This report summarizes our work on high-voltage switches during the past few years. With joint funding from the Department of Energy (DOE) and the Department of Defense (DOD), we tested a wide variety of switches to a common standard. This approach permitted meaningful comparisons between disparate switches. Most switches were purchased from commercial sources, though some were experimental devices. For the purposes of this report, we divided the switches into three generic types (gas, vacuum, and semiconductor) and selected data that best illustrates important strengths and weaknesses of each switch type. Test techniques that indicate the state of health of the switches are emphasized. For example, a good indicator of residual gas in a vacuum switch is the systematic variation of the switching delay in response to changes in temperature and/or operating conditions. We believe that the presentation of this kind of information will help engineers to select and to test switches for their particular applications. Our work was limited to switches capable of driving slappers. Also known as exploding-foil initiators, slappers are detonators that initiate a secondary explosive by direct impact with a small piece of matter moving at the detonation velocity (several thousands of meters per second). A slapper is desirable for enhanced safety (no primary explosive), but it also places extra demands on the capacitor-discharge circuit to deliver a fast-rising current pulse (greater than 10 A/ns) of several thousand amperes. The required energy is substantially less than one joule; but this energy is delivered in less than one microsecond, taking the peak power into the megawatt regime. In our study, the switches operated in the 1 kV to 3 kV range and were physically small, roughly 1 cm{sup 3} or less. Although a fuze functions only once in actual use, multiple-shot capability is important for production testing and for research work. For this reason, we restricted this report to multiple-shot switches. Furthermore, our work included only switches with submicrosecond timing precision, thereby excluding mechanical switches.

Chu, K.W.; Scott, G.L.

1999-02-01T23:59:59.000Z

255

A Process and Supply Variation Tolerant Nano-CMOS Low Voltage, High Speed, A/D Converter for System-on-Chip  

E-Print Network [OSTI]

variations of 10.5% and 5.7% in the INL and DNL respectively, with nominal INL = 0.344LSB and nominal DNL = 0

Mohanty, Saraju P.

256

Unravelling the Performance Degradation Mechanisms in High-voltage...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Unravelling the Performance Degradation Mechanisms in High-voltage Lithium-ion Battery Composite Oxide Electrodes Apr 11 2014 02:00 PM - 03:00 PM Debasish Mohanty, ORNL, Oak Ridge...

257

Stability issues in IC Low Drop Out voltage regulators  

E-Print Network [OSTI]

Performance issues of IC Low Drop Out (LDO) voltage regulators, with specific reference to stability, are discussed in this thesis. Evaluation of existing frequency compensation schemes and their performances across operating loads is presented...

Chava, Krishna Chaitanya

2002-01-01T23:59:59.000Z

258

Operation of buck regulator with ultra-low input voltage  

E-Print Network [OSTI]

Based on the LTC3621 and LTC3624, the designed buck regulator proposed in this thesis aims to lower the allowed input voltage and increase efficiency compared to the original part without making significant changes to ...

Harris, Cory Angelo

2014-01-01T23:59:59.000Z

259

Voltage Dependent Charge Storage Modes and Capacity in Subnanometer Pores  

SciTech Connect (OSTI)

Using molecular dynamics simulations, we show that charge storage in subnanometer pores follows a distinct voltage-dependent behavior. Specifically, at lower voltages, charge storage is achieved by swapping co-ions in the pore with counterions in the bulk electrolyte. As voltage increases, further charge storage is due mainly to the removal of co-ions from the pore, leading to a capacitance increase. The capacitance eventually reaches a maximum when all co-ions are expelled from the pore. At even higher electrode voltages, additional charge storage is realized by counterion insertion into the pore, accompanied by a reduction of capacitance. The molecular mechanisms of these observations are elucidated and provide useful insight for optimizing energy storage based on supercapacitors.

Qiao, Rui [Clemson University; Meunier, V. [Rensselaer Polytechnic Institute (RPI); Huang, Jingsong [ORNL; Wu, Peng [ORNL; Sumpter, Bobby G [ORNL

2012-01-01T23:59:59.000Z

260

An Adaptive Voltage Control Algorithm with Multiple Distributed Energy  

SciTech Connect (OSTI)

Distributed energy resources (DE) with power electronics (PE) interfaces with the right control are capable of providing reactive power related ancillary services. Voltage regulation in particular has drawn much attention. In this paper the challenges to control multiple DEs to regulate the local voltage in distribution systems is addressed and a decentralized adaptive voltage control method is proposed. The simulation results in different system conditions show that this adaptive voltage control method is capable of satisfying the fast response speed requirement without causing oscillation or instability of the system. Since this method has high tolerance to the shortage of the system parameters and can be widely adaptive to the variable operation situations of the power systems, it is very suited for the utility application.

Li, Huijuan [University of Tennessee, Knoxville (UTK); Li, Fangxing [ORNL; Adhikari, Sarina [ORNL; Xu, Yan [ORNL; Rizy, D Tom [ORNL; Kueck, John D [ORNL

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

High frequency AC power converter for low voltage circuits  

E-Print Network [OSTI]

This thesis presents a novel AC power delivery architecture that is suitable for VHF frequency (50-100MHz) polyphase AC/DC power conversion in low voltage integrated circuits. A complete AC power delivery architecture was ...

Salazar, Nathaniel Jay Tobias

2012-01-01T23:59:59.000Z

262

Planar LTCC transformers for high voltage flyback converters: Part II.  

SciTech Connect (OSTI)

This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

Schofield, Daryl (NASCENTechnology, Inc., Watertown, SD); Schare, Joshua M., Ph.D.; Slama, George (NASCENTechnology, Inc., Watertown, SD); Abel, David (NASCENTechnology, Inc., Watertown, SD)

2009-02-01T23:59:59.000Z

263

Secondary Control for Voltage Unbalance Compensation in an Islanded Microgrid  

E-Print Network [OSTI]

coupling (PCC). Unbalance compensation is achieved by proper control of distributed generators (DGs unbalance. Keywords-distributed generation; microgrid; secondary control; voltage unbalance compensation I. INTRODUCTION Distributed Generators (DGs) may be connected individually to the utility grid or be integrated

Vasquez, Juan Carlos

264

IMPACT OF DYNAMIC VOLTAGE SCALING (DVS) ON CIRCUIT OPTIMIZATION  

E-Print Network [OSTI]

Circuit designers perform optimization procedures targeting speed and power during the design of a circuit. Gate sizing can be applied to optimize for speed, while Dual-VT and Dynamic Voltage Scaling (DVS) can be applied to optimize for leakage...

Esquit Hernandez, Carlos A.

2010-01-16T23:59:59.000Z

265

High-voltage air-core pulse transformers  

SciTech Connect (OSTI)

General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

Rohwein, G. J.

1981-01-01T23:59:59.000Z

266

Time varying voltage combustion control and diagnostics sensor  

DOE Patents [OSTI]

A time-varying voltage is applied to an electrode, or a pair of electrodes, of a sensor installed in a fuel nozzle disposed adjacent the combustion zone of a continuous combustion system, such as of the gas turbine engine type. The time-varying voltage induces a time-varying current in the flame which is measured and used to determine flame capacitance using AC electrical circuit analysis. Flame capacitance is used to accurately determine the position of the flame from the sensor and the fuel/air ratio. The fuel and/or air flow rate (s) is/are then adjusted to provide reduced flame instability problems such as flashback, combustion dynamics and lean blowout, as well as reduced emissions. The time-varying voltage may be an alternating voltage and the time-varying current may be an alternating current.

Chorpening, Benjamin T. (Morgantown, WV); Thornton, Jimmy D. (Morgantown, WV); Huckaby, E. David (Morgantown, WV); Fincham, William (Fairmont, WV)

2011-04-19T23:59:59.000Z

267

Sinusoidal voltage controlled oscillators using operational transconductance amplifiers  

E-Print Network [OSTI]

SINUSOIDAI. VOLTAGE CONTROLLED OSCILLATORS I. SING OPERATIONAL TRANSCONDUCTANCE AMPLIFIERS A Thesis JAVIFB . IOAQUIN HOYI. K I'ASSANO Suhndtted to the Graduate College ol' 'I'exes A8cM University in partial fulfillment of the requirement... for the degree of MASTER OF SCIENCE May 1985 Major Subject: Electrical Engineering SINUSOIDAL VOLTAGE CONTROLLED OSCILLATORS USING OPERATIONAI, TRANSCONDUCTANCE AMPLIFIERS A Thesis by JAVIER JOAQUIN HOYLE PASSANO Approved as to style and content by: o...

Hoyle Passano, Javier Joaquin

1985-01-01T23:59:59.000Z

268

Image-line voltage controlled oscillators and grating antennas  

E-Print Network [OSTI]

IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Submitted to the Office of Graduate Studies of Texas ABM University in partial fulfillment of the requirements for the degree of MASTER... OF SCIENCE May 1991 Major Subject: Electrical Engineering IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Approved as to style and content by: Kai Chang (Chair of Committee) Robert D. Nevels...

Kirk, Alexander MacDonald

1991-01-01T23:59:59.000Z

269

Design issues for high voltage converters for ion engines  

SciTech Connect (OSTI)

A design strategy is presented for a power converter for a high voltage ion engine for a spacecraft application. Various design issues such as appropriate topologies and control methods are considered. In this particular instance it was determined that a full bridge converter with phase shift gating and voltage mode control provided an efficient system with a minimum of electromagnetic interference. This system can be implemented in a straightforward manner, and it is relatively easy to protect from faults at the output.

King, R.J.; Stuart, T.A. [Univ. of Toledo, OH (United States)

1995-12-31T23:59:59.000Z

270

LM111/LM211/LM311 Voltage Comparator  

E-Print Network [OSTI]

LM111/LM211/LM311 Voltage Comparator 1.0 General Description The LM111, LM211 and LM311 are voltage comparators that have input currents nearly a thousand times lower than devices like the LM106 or LM710A. Both the inputs and the outputs of the LM111, LM211 or the LM311 can be isolated from system ground

Lanterman, Aaron

271

Measuring Helical FCG Voltage with an Electric Field Antenna  

SciTech Connect (OSTI)

A method of measuring the voltage produced by a helical explosive flux compression generator using a remote electric field antenna is described in detail. The diagnostic has been successfully implemented on several experiments. Measured data from the diagnostic compare favorably with voltages predicted using the code CAGEN, validating our predictive modeling tools. The measured data is important to understanding generator performance, and is measured with a low-risk, minimally intrusive approach.

White, A D; Anderson, R A; Javedani, J B; Reisman, D B; Goerz, D A; Ferriera, A J; Speer, R D

2011-08-01T23:59:59.000Z

272

Centralized wind power plant voltage control with optimal power flow algorithm.  

E-Print Network [OSTI]

??This thesis presents a method of controlling the reactive power injected into a medium-voltage collection system by multiple wind turbine generators such that the voltage… (more)

Kline, Jared Andrew

2011-01-01T23:59:59.000Z

273

High voltage electrical amplifier having a short rise time  

DOE Patents [OSTI]

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

1991-01-01T23:59:59.000Z

274

Effect of interfacial oxide layers on the current-voltage characteristics of Al-Si contacts  

E-Print Network [OSTI]

reported (24). Silicon- Schottky-barrier solar cells having a carefully grown oxide layer in- creased the open-circuit voltage. Also, the minority-carrier injection efficiency of silicon-Schottky diodes were increased by a similar thin-oxide film (25...: Dr. W, A. Porter An experimental study has been made of aluminum-silicon contacts D with very thin interfacial oxide layers (15-100A) and various surface 16 20 impurity concentrations (10 ? 10 atoms/cm ) for both n and p-type silicon...

Nishizono, Taira

1976-01-01T23:59:59.000Z

275

Enhanced sheath heating in capacitively coupled discharges due to non-sinusoidal voltage waveforms  

SciTech Connect (OSTI)

Through the use of particle-in-cell simulations, we demonstrate that the power deposition in capacitively coupled discharges (in argon) can be increased by replacing sinusoidal waveforms with Gaussian-shaped voltage pulses (with a repetition frequency of 13.56 MHz). By changing the Gaussian pulse width, electron heating can be directly controlled, allowing for an increased plasma density and ion flux for the same gas pressure and geometrical operating conditions. Analysis of the power deposition profiles and electron distribution functions shows that enhanced electron-sheath heating is responsible for the increased power absorption.

Lafleur, T. [Johannesburg (South Africa); Boswell, R. W. [Space Plasma, Power and Propulsion Group, Research School of Physics and Engineering, Australian National University, Canberra ACT 0200 (Australia); Booth, J. P. [LPP-CNRS, Ecole Polytechnique, 91128 Palaiseau (France)

2012-05-07T23:59:59.000Z

276

The genera)on and survival of nerve cells  

E-Print Network [OSTI]

the helix-loop-helix transcrip)on factor path Ectodermal cells Proneural region and notch at similar levels Feedback loop Notch signaling Neuronal fate #12 voltage activated calcium channels Schwann cell #12;Astrocytes Protoplasmic astrocytes: gray matter

Alford, Simon

277

Proton Exchange Membrane Fuel Cell degradation prediction based on Adaptive Neuro Fuzzy Inference Systems  

E-Print Network [OSTI]

Proton Exchange Membrane Fuel Cell degradation prediction based on Adaptive Neuro Fuzzy Inference online XX XX XXXX Keywords: Proton Exchange Membrane fuel cell degradation, Prognostic and Health nominal operating condition of a PEM fuel cell stack. It proposes a methodology based on Adaptive Neuro

Paris-Sud XI, Université de

278

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

Shimer, D.W.; Lange, A.C.

1997-03-11T23:59:59.000Z

279

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1997-01-01T23:59:59.000Z

280

Fuel cell CO sensor  

DOE Patents [OSTI]

The CO concentration in the H.sub.2 feed stream to a PEM fuel cell stack is monitored by measuring current and/or voltage behavior patterns from a PEM-probe communicating with the reformate feed stream. Pattern recognition software may be used to compare the current and voltage patterns from the PEM-probe to current and voltage telltale outputs determined from a reference cell similar to the PEM-probe and operated under controlled conditions over a wide range of CO concentrations in the H.sub.2 fuel stream. A CO sensor includes the PEM-probe, an electrical discharge circuit for discharging the PEM-probe to monitor the CO concentration, and an electrical purging circuit to intermittently raise the anode potential of the PEM-probe's anode to at least about 0.8 V (RHE) to electrochemically oxidize any CO adsorbed on the probe's anode catalyst.

Grot, Stephen Andreas (Rochester, NY); Meltser, Mark Alexander (Pittsford, NY); Gutowski, Stanley (Pittsford, NY); Neutzler, Jay Kevin (Rochester, NY); Borup, Rodney Lynn (East Rochester, NY); Weisbrod, Kirk (Los Alamos, NM)

1999-12-14T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Nanosecond pulsed electric fields (nsPEFs) low cost generator design using power MOSFET and Cockcroft-Walton multiplier circuit as high voltage DC source  

SciTech Connect (OSTI)

Purpose: Non-ionizing radiation therapy for cancer using pulsed electric field with high intensity field has become an interesting field new research topic. A new method using nanosecond pulsed electric fields (nsPEFs) offers a novel means to treat cancer. Not like the conventional electroporation, nsPEFs able to create nanopores in all membranes of the cell, including membrane in cell organelles, like mitochondria and nucleus. NsPEFs will promote cell death in several cell types, including cancer cell by apoptosis mechanism. NsPEFs will use pulse with intensity of electric field higher than conventional electroporation, between 20–100 kV/cm and with shorter duration of pulse than conventional electroporation. NsPEFs requires a generator to produce high voltage pulse and to achieve high intensity electric field with proper pulse width. However, manufacturing cost for creating generator that generates a high voltage with short duration for nsPEFs purposes is highly expensive. Hence, the aim of this research is to obtain the low cost generator design that is able to produce a high voltage pulse with nanosecond width and will be used for nsPEFs purposes. Method: Cockcroft-Walton multiplier circuit will boost the input of 220 volt AC into high voltage DC around 1500 volt and it will be combined by a series of power MOSFET as a fast switch to obtain a high voltage with nanosecond pulse width. The motivation using Cockcroft-Walton multiplier is to acquire a low-cost high voltage DC generator; it will use capacitors and diodes arranged like a step. Power MOSFET connected in series is used as voltage divider to share the high voltage in order not to damage them. Results: This design is expected to acquire a low-cost generator that can achieve the high voltage pulse in amount of ?1.5 kV with falltime 3 ns and risetime 15 ns into a 50? load that will be used for nsPEFs purposes. Further detailed on the circuit design will be explained at presentation.

Sulaeman, M. Y.; Widita, R. [Department of Physics, Nuclear Physics and Biophysics Research Division, Faculty of Mathematics and Natural Science, Institut Teknologi Bandung, Bandung (Indonesia)

2014-09-30T23:59:59.000Z

282

Voltage control in pulsed system by predict-ahead control  

DOE Patents [OSTI]

A method and apparatus for predict-ahead pulse-to-pulse voltage control in a pulsed power supply system is disclosed. A DC power supply network is coupled to a resonant charging network via a first switch. The resonant charging network is coupled at a node to a storage capacitor. An output load is coupled to the storage capacitor via a second switch. A de-Q-ing network is coupled to the resonant charging network via a third switch. The trigger for the third switch is a derived function of the initial voltage of the power supply network, the initial voltage of the storage capacitor, and the present voltage of the storage capacitor. A first trigger closes the first switch and charges the capacitor. The third trigger is asserted according to the derived function to close the third switch. When the third switch is closed, the first switch opens and voltage on the node is regulated. The second trigger may be thereafter asserted to discharge the capacitor into the output load. 4 figs.

Payne, A.N.; Watson, J.A.; Sampayan, S.E.

1994-09-13T23:59:59.000Z

283

DATE04 SPECIAL SECTION Overhead-conscious voltage selection for dynamic  

E-Print Network [OSTI]

combination with dynamic voltage scaling indispensable for energy-efficient designs in the foreseeable future

Marchal, Loris

284

Requirements for a Standard Test to Rate the Durability of PV Modules at System Voltage (Presentation)  

SciTech Connect (OSTI)

Degradation modes in photovoltaic modules under system bias voltage stress are described and classified.

Hacke, P.; Terwilliger, K.; Glick, S.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-02-01T23:59:59.000Z

285

Concept of Quasi-Capacitive Tapping of Bipolar Voltage-Controlled Oscillators  

E-Print Network [OSTI]

Concept of Quasi-Capacitive Tapping of Bipolar Voltage-Controlled Oscillators Aleksandar Tasic the active part of the oscillator and the LC-tank, as proposed in this paper, the voltage swing over the tank of high- performance bipolar voltage-controlled oscillators (VCO's). As the voltage-controlled oscillators

Serdijn, Wouter A.

286

Neurocomputing 69 (2006) 10621065 Dependence of the spike-triggered average voltage on  

E-Print Network [OSTI]

.V. All rights reserved. Keywords: Spike-triggered voltage; h-current; Damped voltage oscillations 1 oscillations. The model comprises a variable v for the membrane voltage, with time-scale tv and a secondNeurocomputing 69 (2006) 1062­1065 Dependence of the spike-triggered average voltage on membrane

Gerstner, Wulfram

2006-01-01T23:59:59.000Z

287

Radio-Frequency Interference (RFI) From Extra-High-Voltage (EHV) Transmission Lines  

E-Print Network [OSTI]

-current (HVAC) transmission lines; high-voltage direct-current (HVDC) transmission lines will be addressed

Ellingson, Steven W.

288

NOMINATION FOR THE PROJECT MANAGEMENT INSTITUTE (PMI) PROJECT OF THE YEAR AWARD INTEGRATED DISPOSAL FACILITY (IDF)  

SciTech Connect (OSTI)

CH2M HILL Hanford Group, Inc. (CH2M HILL) is pleased to nominate the Integrated Disposal Facility (IDF) project for the Project Management Institute's consideration as 2007 Project of the Year, Built for the U.S, Department of Energy's (DOE) Office of River Protection (ORP) at the Hanford Site, the IDF is the site's first Resource Conservation and Recovery Act (RCRA)-compliant disposal facility. The IDF is important to DOE's waste management strategy for the site. Effective management of the IDF project contributed to the project's success. The project was carefully managed to meet three Tri-Party Agreement (TPA) milestones. The completed facility fully satisfied the needs and expectations of the client, regulators and stakeholders. Ultimately, the project, initially estimated to require 48 months and $33.9 million to build, was completed four months ahead of schedule and $11.1 million under budget. DOE directed construction of the IDF to provide additional capacity for disposing of low-level radioactive and mixed (i.e., radioactive and hazardous) solid waste. The facility needed to comply with federal and Washington State environmental laws and meet TPA milestones. The facility had to accommodate over one million cubic yards of the waste material, including immobilized low-activity waste packages from the Waste Treatment Plant (WTP), low-level and mixed low-level waste from WTP failed melters, and alternative immobilized low-activity waste forms, such as bulk-vitrified waste. CH2M HILL designed and constructed a disposal facility with a redundant system of containment barriers and a sophisticated leak-detection system. Built on a 168-area, the facility's construction met all regulatory requirements. The facility's containment system actually exceeds the state's environmental requirements for a hazardous waste landfill. Effective management of the IDF construction project required working through highly political and legal issues as well as challenges with permitting, scheduling, costs, stakeholders and technical issues. To meet the customer's needs and deadlines, the project was managed with conscientious discipline and application of sound project management principles in the Project Management Institute's Project Management Body of Knowledge. Several factors contributed to project success. Extensive planning and preparation were conducted, which was instrumental to contract and procurement management. Anticipating issues and risks, CH2M HILL prepared well defined scope and expectations, particularly for safety. To ensure worker safety, the project management team incorporated CH2M HILL's Integrated Safety Management System (ISMS) into the project and included safety requirements in contracting documents and baseline planning. The construction contractor DelHur Industries, Inc. adopted CH2M HILL's safety program to meet the procurement requirement for a comparable ISMS safety program. This project management approach contributed to an excellent safety record for a project with heavy equipment in constant motion and 63,555 man-hours worked. The project manager worked closely with ORP and Ecology to keep them involved in project decisions and head off any stakeholder or regulatory concerns. As issues emerged, the project manager addressed them expeditiously to maintain a rigorous schedule. Subcontractors and project contributors were held to contract commitments for performance of the work scope and requirements for quality, budget and schedule. Another element of project success extended to early and continual involvement of all interested in the project scope. Due to the public sensitivity of constructing a landfill planned for radioactive waste as well as offsite waste, there were many stakeholders and it was important to secure their agreement on scope and time frames. The project had multiple participants involved in quality assurance surveillances, audits and inspections, including the construction contractor, CH2M HILL, ORP, the Washington State Department of Ecology, and independent certified quality assurance an

MCLELLAN, G.W.

2007-02-07T23:59:59.000Z

289

High voltage stability performance of a gamma ray detection device  

SciTech Connect (OSTI)

An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

Abdullah, Nor Arymaswati; Lombigit, Lojius; Rahman, Nur Aira Abd [Technical Support Division, Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)

2014-02-12T23:59:59.000Z

290

Voltage Impacts of Utility-Scale Distributed Wind  

SciTech Connect (OSTI)

Although most utility-scale wind turbines in the United States are added at the transmission level in large wind power plants, distributed wind power offers an alternative that could increase the overall wind power penetration without the need for additional transmission. This report examines the distribution feeder-level voltage issues that can arise when adding utility-scale wind turbines to the distribution system. Four of the Pacific Northwest National Laboratory taxonomy feeders were examined in detail to study the voltage issues associated with adding wind turbines at different distances from the sub-station. General rules relating feeder resistance up to the point of turbine interconnection to the expected maximum voltage change levels were developed. Additional analysis examined line and transformer overvoltage conditions.

Allen, A.

2014-09-01T23:59:59.000Z

291

National Fuel Cell Research Center  

E-Print Network [OSTI]

National Fuel Cell Research Center www.nfcrc.uci.edu SOFC AND PEMFC COMPARISON Efficiency ­ Higher operating voltages and temperatures and reduced fuel processing requirements give SOFCs an efficiency FOR OPTIMIZATION · Fuel Cell · Compressor · Combustor · Turbine · Storage Tank · Heat Exchanger·Battery · Motor

Mease, Kenneth D.

292

Voltage and pressure scaling of streamer dynamics in a helium plasma jet with N{sub 2} co-flow  

SciTech Connect (OSTI)

Positive polarity applied voltage and gas pressure dependent scaling of cathode directed streamer propagation properties in helium gas flow guided capillary dielectric barrier discharge have been quantified from streamer velocity, streamer current, and streamer optical diameter measurements. All measurements of the non-stochastic streamer properties have been performed in a variable gas pressure glass cell with N{sub 2} co-flow and under self-consistent Poisson electric field dominated conditions to permit data comparison with 2-D streamer dynamics models in air/nitrogen. The streamer optical diameter was found to be nearly independent of both gas pressures, from 170?Torr up to 760?Torr, and also for applied voltages from 6 to 11?kV at 520?Torr. The streamer velocity was found to increase quadratically with increased applied voltage. These observed differences in the 2-D scaling properties of ionization wave sustained cathode directed streamer propagation in helium flow channel with N{sub 2} annular co-flow compared to the streamer propagation in air or nitrogen have been shown to be caused by the remnant ionization distribution due to large differences in the dissociative recombination rates of He{sub 2}{sup +} versus N{sub 4}{sup +} ions, for this 5?kHz repetition rate applied voltage pulse generated streamers.

Leiweke, Robert J. [UES, Inc., 4401 Dayton-Xenia Road, Dayton, Ohio 45432 (United States); Ganguly, Biswa N.; Scofield, James D. [Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433-7919 (United States)

2014-08-15T23:59:59.000Z

293

A study of temperature compensating circuits for voltage references which use negative temperature coefficient zener diodes  

E-Print Network [OSTI]

Character- istics in Breakdown Region . 13 3f. 1N 751 Zener Diode Voltage vs Current Character- istics in Breakdown Region . 14 3g, lN752 Zener Diode Voltage vs Current Character- istics in Breakdown Region 15 4a. 1N746 Zener Diode Ambient Temperature... vs Voltage Characteristics in Breakdown Region. . . . . . . . . . 16 4b. IN747 Zener Diode Ambient Temperature vs Voltage Characteristics in Breakdown Region. . . . . . . . . . 17 4c. 1N748 Zener Diode Ambient Temperature vs Voltage...

Coleman, Spencer Delano

1961-01-01T23:59:59.000Z

294

Investigating the efficiency of Silicon Solar cells at  

E-Print Network [OSTI]

Investigating the efficiency of Silicon Solar cells at different temperatures and wavelengths to study the characteristics of silicon photovoltaic cells (solar cells). We vary the wavelength of light as well as the temperature of the solar cell to investigate how the open voltage across the cell varies

Attari, Shahzeen Z.

295

Reduction of interference on substation low voltage wiring  

SciTech Connect (OSTI)

This paper describes test results and mitigation methods of electromagnetic interference (EMI) on control and low voltage circuits in substations caused by air disconnect switch operation. The tests are focused on a comparison between unshielded and shielded circuits from capacitively coupled voltage transformers (CCVT) and other equipment circuits in the vicinity. New test data are presented comparing unshielded and shielded cables and transient currents on all connections to the CCVT including the pedestal and ground strap. The paper gives a practical and understandable explanation of the causes of EMI in substations and how shielded cable and parallel ground conductors reduce interference. Design guidelines are listed in the Conclusion.

Gavazza, R.J. [Pacific Gas and Electric Co., San Francisco, CA (United States)] [Pacific Gas and Electric Co., San Francisco, CA (United States); Wiggins, C.M. [Carl M. Wiggins and Associates, Friendswood, TX (United States)] [Carl M. Wiggins and Associates, Friendswood, TX (United States)

1996-07-01T23:59:59.000Z

296

Experimental characterization of faults on low-voltage systems  

E-Print Network [OSTI]

arcing ground faults '10'. The first scheme is very similar to the Ground Sensor Protection scheme described in i8j. The second scheme employs the fact that the voltage waveshape at the 1'suit point is flat topped. Harmonic analysis shows that... value when an arcing fault takes place. Continued presence of a, relatively high third- harmonic component in the bus voltage is a definite sign that there is an arcing fault in the system, Kusko and Peeran recommended the use of a, third harmonic...

Ahmed, Jubayer

1992-01-01T23:59:59.000Z

297

Conditions for Capacitor Voltage Regulation in a Five-Level Cascade Multilevel Inverter: Application to Voltage-Boost in a PM Drive  

E-Print Network [OSTI]

Conditions for Capacitor Voltage Regulation in a Five-Level Cascade Multilevel Inverter Abstract-- A cascade multilevel inverter is a power electronic device built to synthesize a desired AC voltage from several levels of DC voltages. Such inverters have been the subject of research in the last

Tolbert, Leon M.

298

Chapter 24: Alternating-Current Circuits 2. The voltage in the European wall socket oscillates between the positive and negative peak voltages, resulting in an rms  

E-Print Network [OSTI]

1 Chapter 24: Alternating-Current Circuits 2. The voltage in the European wall socket oscillates 240 V 340 VV V 6. A light bulb dissipates power as the voltage oscillates across its filament.0 V 1.32 A 15.2 V I X 13. An oscillating voltage drives an alternating current through a capacitor

Kioussis, Nicholas

299

Voltage Sequence Control Based High-Current Rectifier System  

E-Print Network [OSTI]

of transformer. A passive filter is added at the primary side to achieve power factor improvement over the range of output voltage. This scheme is optimized to determine optimum turns ratio of the transformer and optimum not enforce unity power factor operation and guidelines provided by harmonic standards such as IEEE-519

Paderborn, Universität

300

Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids  

E-Print Network [OSTI]

Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids Mehdi@et.aau.dk Abstract-- The concept of microgrid hierarchical control is presented, recently. In this paper, a hierarchical scheme which includes primary and secondary control levels is proposed for islanded microgrids

Vasquez, Juan Carlos

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

ORIGINAL ARTICLES Induced Transmembrane Voltage and Its Correlation  

E-Print Network [OSTI]

to investigate the correlation between DWm and molecular transport through an elec- troporated membrane to a voltage (electric potential difference) caused by a system of ion pumps and channels in the membrane, or electropermea- bilization, and permits transmembrane transport of mole- cules for which an intact membrane

Ljubljana, University of

302

Topical Review Voltage Dependence of the Na/K Pump  

E-Print Network [OSTI]

or ``ion well'' hy- pothesis. There are only two ways that net transport can be voltage dependent. Either of the external Na+ and K+ bind- ing sites within the membrane field. This access channel or ``ion well produced by applying a blocking Key words: Na,K-ATPase -- Membrane potential -- Access channel -- Ion well

Gadsby, David

303

Current isolating epitaxial buffer layers for high voltage photodiode array  

DOE Patents [OSTI]

An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

2002-01-01T23:59:59.000Z

304

Ultra LowVoltage Delay Locked Loop Using Carbon Nanotubes  

E-Print Network [OSTI]

Ultra LowVoltage Delay Locked Loop Using Carbon Nanotubes J.S. Ajit Northeastern University Dept, MA 02115 E-mail: ybk@ece.neu.edu AbstractCarbon Nanotube FET technology is investigated for both the shrinking process to continue, and for the development of novel architectures, is the carbon

Ayers, Joseph

305

Memory Power Management via Dynamic Voltage/Frequency Scaling  

E-Print Network [OSTI]

years. In the data center environment, thermal management and power budgeting have become significant transitions [10, 23], or scal- ing active server power proportionally to load [2]. In this paper, we focusMemory Power Management via Dynamic Voltage/Frequency Scaling Howard David, Chris Fallin§, Eugene

McGaughey, Alan

306

Memory Power Management via Dynamic Voltage/Frequency Scaling  

E-Print Network [OSTI]

years. In the data center environment, thermal management and power budgeting have become significant sleep transitions [10, 23], or scal- ing active server power proportionally to load [2]. In this paperMemory Power Management via Dynamic Voltage/Frequency Scaling Howard David, Chris Fallin§, Eugene

Mutlu, Onur

307

The Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions  

E-Print Network [OSTI]

that generates variable magnitude variable frequency output voltage from the ac utility line. It has high power conversion device, the disturbances at the ac utility grid (line) side are immediately reflected to the load and large capacitor associated with it, there is no stored energy in the MC. As a result, the utility line

Hava, Ahmet

308

Way to reduce arc voltage losses in hybrid thermionic converters  

SciTech Connect (OSTI)

Experimental results are reported concerning the output and emission characteristics of the arc and hybrid regimes in a plane-parallel thermionic converter with Pt--Zr--O electrode pair. It is shown that arc voltage losses can be reduced to values below those obtainable in ordinary arc thermionic converters.

Tskhakaya, V.K.; Yarygin, V.I.

1982-03-01T23:59:59.000Z

309

Field Optimization of Three Dimensional High Voltage C. Trinitis  

E-Print Network [OSTI]

Field Optimization of Three Dimensional High Voltage Equipment C. Trinitis Lehrstuhl f The goal of finding an optimal electric field strength distribution for arbitrary three di­ mensional­ cal optimization algorithm. The package ob­ tained from these three components is then able

Stamatakis, Alexandros

310

High Voltage DC Transmission 1.0 Introduction  

E-Print Network [OSTI]

1 High Voltage DC Transmission 1.0 Introduction HVDC has been applied in electric power systems for many years now. Figure 1 illustrates worldwide many of the HVDC applications [1]. Fig. 1 ABB provides a webpage which summarizes HVDC projects by type and capacity or by commissioning year [2]. Wikipedia [3

McCalley, James D.

311

High Voltage DC Transmission 2 1.0 Introduction  

E-Print Network [OSTI]

1 High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires on use of switching devices collectively referred to in the HVDC community as valves. Valves may be non. Fig. 1 There have been three types of devices for implementing HVDC converter circuits: mercury

McCalley, James D.

312

Smart Grid Voltage Sag Detection using Instantaneous Features Extraction  

E-Print Network [OSTI]

Smart Grid Voltage Sag Detection using Instantaneous Features Extraction Yassine Amirat, Mohamed Benbouzid, Tianzhen Wang and Sylvie Turri Abstract--Smart grids have initiated a radical reappraisal, and effective use of the network are indexed as the most important keys for smart grid expansion and deployment

Boyer, Edmond

313

Low Beam Voltage, 10 MW, L-Band Cluster Klystron  

SciTech Connect (OSTI)

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

Teryaev, V.; /Novosibirsk, IYF; Yakovlev, V.P.; /Fermilab; Kazakov, S.; /KEK, Tsukuba; Hirshfield, J.L.; /Yale U. /Omega-P, New Haven

2009-05-01T23:59:59.000Z

314

Addition and subtraction of spin pumping voltages in magnetic hybrid structures  

SciTech Connect (OSTI)

We report an investigation of the spin pumping voltage generated in bilayers of ferromagnetic/normal metal in which the ferromagnetic layer is yttrium iron garnet or Permalloy and the normal-metal layer is Pt or Ta. We also investigated a special case in which the voltage is detected in single layer of Permalloy under ferromagnetic resonance condition. It is shown that the spin pumping voltage generated in metallic bilayers have contributions from both layers and the resulting voltage depends on the relative signs of charge currents generated by the inverse spin Hall effect. For instance, the spin pumping voltage generated in Ta has the same sign as the one generate in single layer of Permalloy, but contrary to the voltage generated in Pt. When the voltage is measured in shunted metallic bilayers, the resulting voltage can be a sum or a subtraction of the voltages generated in both layers.

Azevedo, A., E-mail: aac@df.ufpe.br; Alves Santos, O.; Cunha, R. O.; Rezende, S. M. [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Rodríguez-Suárez, R. [Facultad de Física, Pontificia Universidad Católica de Chile, Casilla 306, Santiago (Chile)

2014-04-14T23:59:59.000Z

315

Coupling between the voltage-sensing and pore domains in a voltage-gated potassium channel  

E-Print Network [OSTI]

-dependent potassium (Kv), sodium (Nav), and calcium channels open and close in response to changes in transmembrane (TM) potential, thus regulating cell excitability by controlling ion flow across the membrane, but it is generally accepted that, when the channel is closed, the VSDs adopt a "down-state" configuration in which

White, Stephen

316

DC BUFFERING AND FLOATING CURRENT FOR A HIGH VOLTAGE IMB APPLICATION  

SciTech Connect (OSTI)

An interface technique for the latest generation of the Impedance Measurement Box (IMB) has been conceived to enable measurement of impedance spectra for battery modules up to 300V. A 300V capable or higher IMB is an enabling technology for in-situ diagnostics within electric vehicle charging stations or battery back-ups within power distribution sub-stations. It is possible that the existing IMB can be adapted via a 300V interface module to a test battery with voltage significantly greater than 50V. Recently a new concept was conceived for the calibration, algorithm and electronics of the IMB. That algorithm and calibration for that concept have been physically validated. The principal feature of the new electronics is the floating current source excitation of the battery under test. The single ended current excitation of the battery under test, used in the 50V IMB, requires that the negative terminal of the test battery must be the analog ground for the IMB. The new floating current technique allows the test battery to be fully high impedance isolated for a measurement. That isolation will improve IMB noise immunity and enable interrogation of cells internal to a battery module. All these techniques still use the same rapid concept for impedance measurement with the IMB. The purpose of this disclosure is to provide an overview of the analytical validation for three concepts to interface the floating current excitation to a high voltage battery. Recursive simulation models were used in different test scenarios to validate the various new concepts. The analysis will show that it is possible to interface the floating signal current to obtain an impedance measurement on a high voltage test battery. Additionally, the analysis will investigate stress seen by electronics while testing a 300V battery.

J.L. Morrison

2014-08-01T23:59:59.000Z

317

EELE408 Photovoltaics Lecture 11: Solar Cell Parameters  

E-Print Network [OSTI]

mV ­ Commercial silicon solar cells 500-600 mV 11 Power & IV Curve · Power (Watts) is the rate · The power output by a source is the product of the current supplied and the voltage at which the current was supplied 12 · Power output = Source voltage x Source current ­ P=V x I (Watts = Joules/second) = (Volts

Kaiser, Todd J.

318

Tonotopic map of potassium currents in chick auditory hair cells using an intact basilar papilla  

E-Print Network [OSTI]

electrical properties of the hair cells. Tall hair cells show membrane voltage oscillations in response membrane voltage oscillations that arise from the in- trinsic membrane conductances. This property of hair at the resonant frequency. These oscillations and the underlying currents have been studied in enzymatically

Rubel, Edwin

319

Optimal Distributed Voltage Regulation in Power Distribution Networks  

E-Print Network [OSTI]

In this paper, we address the problem of voltage regulation in power distribution networks with deep-penetration of distributed energy resources (DERs), e.g., renewable-based generation, and storage-capable loads such as plug-in hybrid electric vehicles. We cast the problem as an optimization program, where the objective is to minimize the losses in the network subject to constraints on bus voltage magnitudes, limits on active and reactive power injections, transmission line thermal limits and losses. We provide sufficient conditions under which the optimization problem can be solved via its convex relaxation. Using data from existing networks, we show that the conditions are expected to be satisfied by most networks. We also provide an efficient distributed algorithm to solve the problem. The algorithm is asynchronous, with a communication topology that is the same as the electrical network topology. We illustrate the algorithm's performance in the IEEE 34-bus and the 123-bus feeder test systems.

Lam, Albert Y S; Dominguez-Garcia, Alejandro; Tse, David

2012-01-01T23:59:59.000Z

320

Evaluation of Conservation Voltage Reduction (CVR) on a National Level  

SciTech Connect (OSTI)

Conservation Voltage Reduction (CVR) is a reduction of energy consumption resulting from a reduction of feeder voltage. While there have been numerous CVR systems deployed in North America there has been little substantive analytic analysis of the effect; the majority of the published results are based on empirical field measurements. Since these results are based on empirical measurements it is difficult to extrapolate how this technology will behave on the various types of distribution feeders found throughout the nation. This report has utilized the Taxonomy of Prototypical feeder developed under the Modern Grid Initiative (MGI), now the Modern Grid Strategy (MGS), in order to estimate the benefits of CVR on multiple distribution feeder types. This information will then be used to determine an estimate of the national benefits of a wide scale deployment of CVR.

Schneider, Kevin P.; Fuller, Jason C.; Tuffner, Francis K.; Singh, Ruchi

2010-09-29T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Interline photovoltaic (I-PV) power plants for voltage unbalance compensation  

E-Print Network [OSTI]

This paper proposes a stationary-frame control method for voltage unbalance compensation using Interline Photovoltaic (I-PV) power system. I-PV power systems are controlled to compensate voltage unbalance autonomously. The ...

Moawwad, Ahmed

322

A low-voltage zero-crossing-based delta-sigma analog-to-digital converter  

E-Print Network [OSTI]

A zero-crossing-based (ZCB) switched-capacitor technique is presented for operation under low power supply voltages without gate boosting. Voltage ramp generators maintain common-mode level at each integrator output. ...

Guyton, Matthew C. (Matthew Christopher)

2010-01-01T23:59:59.000Z

323

E-Print Network 3.0 - applied voltages ii Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dc-link voltage error is applied to the fun... --In this paper, a new hybrid active power filter topology is presented. A higher-voltage, low-switching fre... - quency...

324

E-Print Network 3.0 - ac voltage standard Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

"volts, AC"), the "secondary" voltage is roughly 6 VAC. We shall use the "Universal Transformer... :" conversion of AC to DC You can use a diode to convert the AC voltage of the...

325

Low Voltage Reversible Electrowetting Exploiting Lubricated Polymer Honeycomb Substrates  

E-Print Network [OSTI]

Low-voltage electrowetting-on-dielectric scheme realized with lubricated honeycomb polymer surfaces is reported. Polycarbonate honeycomb reliefs manufactured with the breath-figures self-assembly were impregnated with silicone and castor oils. The onset of the reversible electrowetting for silicone oil impregnated substrates occurred at 35 V, whereas for castor oil impregnated ones it took place at 80 V. The semi-quantitative analysis of electrowetting of impregnated surfaces is proposed.

Edward Bormashenko; Roman Pogreb; Yelena Bormashenko; Roman Grynyov; Oleg Gendelman

2014-06-16T23:59:59.000Z

326

Process for measuring degradation of sulfur hexafluoride in high voltage systems  

DOE Patents [OSTI]

This invention is a method of detecting the presence of toxic and corrosive by-products in high voltage systems produced by electrically induced degradation of SF/sub 6/ insulating gas in the presence of certain impurities. It is an improvement over previous methods because it is extremely sensitive, detecting by-products present in parts per billion concentrations, and because the device employed is of a simple design and takes advantage of the by-products natural affinity for fluoride ions. The method employs an ion-molecule reaction cell in which negative ions of the by-products are produced by fluorine attachment. These ions are admitted to a negative ion mass spectrometer and identified by their spectra. This spectrometry technique is an improvement over conventional techniques because the negative ion peaks are strong and not obscured by a major ion spectra of the SF/sub 6/ component as is the case in positive ion mass spectrometry.

Sauers, I.

1985-04-23T23:59:59.000Z

327

Advanced Gate Drive for the SNS High Voltage Converter Modulator  

SciTech Connect (OSTI)

SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

328

Linear inductive voltage adders (IVA) for advanced hydrodynamic radiography  

SciTech Connect (OSTI)

The electron beam which drifts through the multiple cavities of conventional induction linacs (LIA) is replaced in an IVA by a cylindrical metal conductor which extends along the entire length of the device and effectuates the addition of the accelerator cavity voltages. In the approach to radiography, the linear inductive voltage adder drives a magnetically immersed electron diode with a millimeter diameter cathode electrode and a planar anode/bremsstrahlung converter. Both anode and cathode electrodes are immersed in a strong (15--50 T) solenoidal magnetic field. The electron beam cross section is approximately of the same size as the cathode needle and generates a similar size, very intense x-ray beam when it strikes the anode converter. An IVA driven diode can produce electron beams of equal size and energy as a LIA but with much higher currents (40--50 kA versus 4--5 kA), simpler hardware and thus lower cost. The authors present here first experimental validations of the technology utilizing HERMES 3 and SABRE IVA accelerators. The electron beam voltage and current were respectively of the order of 10 MV and 40 kA. X-ray doses of up to 1 kR {at} 1 m and spot sizes as small as 1.7 mm (at 200 R doses) were measured.

Mazarakis, M.G.; Boyes, J.D.; Johnson, D.L. [and others

1998-09-01T23:59:59.000Z

329

Electrochimica Acta 51 (2006) 39243933 Dynamics of polymer electrolyte fuel cells undergoing load changes  

E-Print Network [OSTI]

in a substantial drop in cell voltage and hence temporary power loss. Under extreme situations such as dry anode reverse, resulting in not only power loss but also cell degradation. Finally, the dynamics of current

2006-01-01T23:59:59.000Z

330

The vertical voltage termination technique characterizations of single die multiple 600V power  

E-Print Network [OSTI]

The vertical voltage termination technique ­ characterizations of single die multiple 600V power.grenoble-inp.fr Abstract-- Deep trench terminations are commonly known as a technique to achieve ideal breakdown voltages for high voltage devices. This paper presents the use of deep trench terminations as an original concept

Paris-Sud XI, Université de

331

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power Filter Applications  

E-Print Network [OSTI]

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power voltage-source inverters connected in series (known as cascaded hybrid asymmetric multilevel inverter scheme is developed to allow the operation of the inverter modules at different voltages and switching

Catholic University of Chile (Universidad Católica de Chile)

332

Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines  

E-Print Network [OSTI]

Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines: State-of-the-Art Review deals with low-voltage ride-through (LVRT) capability of wind turbines (WTs) and in particular those as to index some emerging solutions. Index Terms--Wind turbine, doubly-fed induction generator, low voltage

Paris-Sud XI, Université de

333

Re-Dispatching Generation to Increase Power System Security Margin and Support Low Voltage Bus  

E-Print Network [OSTI]

Re-Dispatching Generation to Increase Power System Security Margin and Support Low Voltage Bus by re-dispatching generator outputs, using a normal vector found at a voltage collapse boundary or a low voltage boundary (LVB). This method uses the normal vector as an indicator to change the generation

334

Parameter Variation Analysis for Voltage Controlled Oscillators in Phase-Locked Loops  

E-Print Network [OSTI]

Parameter Variation Analysis for Voltage Controlled Oscillators in Phase-Locked Loops Igor Vytyaz), the oscillation frequency of a voltage-controlled oscillator (VCO) is specified by the reference frequency on the oscillation frequency as the PLL adjusts the control voltage to keep the frequency unchanged. More importantly

Moon, Un-Ku

335

1. ABSTRACT A 1.4-GHz LC voltage-controlled oscillator has  

E-Print Network [OSTI]

1. ABSTRACT A 1.4-GHz LC voltage-controlled oscillator has been implemented in a MOSIS 0.5-µm CMOS integrated, low noise, low power voltage-controlled oscillator (VCO). For higher quality receivers, an LC the overall phase noise. In this paper, we present such an LC voltage-controlled oscillator fabricated through

Lee, Thomas H.

336

EFFECTS OF SUBSTRATE ON PHASE-NOISE OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS  

E-Print Network [OSTI]

EFFECTS OF SUBSTRATE ON PHASE-NOISE OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS Aleksandar Tasic predict a dramatically different performance of the oscillators, being different phase-noise, voltage of quasi-tapped bipolar voltage-controlled oscillators [2], phase- noise being of most interest. Contrary

Serdijn, Wouter A.

337

Fast Optimization of Nano-CMOS Voltage-Controlled Oscillator using Polynomial Regression and Genetic Algorithm  

E-Print Network [OSTI]

Fast Optimization of Nano-CMOS Voltage-Controlled Oscillator using Polynomial Regression in a current-starved 50nm voltage-controlled oscillator (VCO). Accurate polynomial-regression based models have-CMOS), Voltage-Controlled Oscillator (VCO). 1. Introduction Digital design exploration and optimization is highly

Mohanty, Saraju P.

338

CONCEPT OF FREQUENCY-TRANSCONDUCTANCE TUNING OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS  

E-Print Network [OSTI]

CONCEPT OF FREQUENCY-TRANSCONDUCTANCE TUNING OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS Aleksandar-transconductance tuning, introduced in this paper, offers the possibility for voltage-controlled oscillators to trade-tank, the loop-gain, the voltage swing and the phase-noise of the oscillator are changed as well

Serdijn, Wouter A.

339

Understanding Pound-Drever-Hall locking using voltage controlled radio-frequency oscillators: An undergraduate experiment  

E-Print Network [OSTI]

Understanding Pound-Drever-Hall locking using voltage controlled radio-frequency oscillators. The three main pieces of equipment are a commercial voltage controlled oscillator, a resonating cavity of the voltage controlled oscillator. The cavity resonance is then observed by scanning the frequency

Le Roy, Robert J.

340

Milligram-Scale High-Voltage Power Electronics for Piezoelectric Microrobots  

E-Print Network [OSTI]

, the generation of high voltages for HMF actu- ators requires voltage conversion circuits with step-up ratios to the voltage step-up functionality, the power electronics circuitry must generate a time-varying signal ranging from 50 to 100. While there are a number of circuit topologies with high step-up ratios, many

Wood, Robert

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Application-Directed Voltage Scaling Johan Pouwelse, Koen Langendoen, and Henk Sips  

E-Print Network [OSTI]

--Clock (and voltage) scheduling is an important tech- nique to reduce the energy consumption of processors that sup- port voltage scaling. It is difficult, however, to achieve good re- sults using only statistics to the scheduler control- ling the clock speed and processor voltage. This paper describes our Energy Priority

Pouwelse, Johan

342

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares in the  

E-Print Network [OSTI]

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares high-voltage transformer spares throughout the electric grid to mitigate the risk of random transformer-voltage transformers are an integral part of the electric transmission system. A catas- trophic transformer failure

Powell, Warren B.

343

Voltage-Sensitivity of Motoneuron NMDA Receptor Channels Is Modulated by Serotonin in the Neonatal Rat Spinal Cord  

E-Print Network [OSTI]

isolated in tetrodotoxin, induces nonlinear membrane behavior that results in voltage oscillations which generate rhythmic voltage oscillations in the presence of NMDA and synaptic blockade (with tetrodotoxin application induces neither voltage oscillations (in synaptically isolated motoneurons) nor locomotor network

Manitoba, University of

344

Strategies for Voltage Control and Transient Stability Assessment  

SciTech Connect (OSTI)

As wind generation grows, its influence on power system performance will becoming increasingly noticeable. Wind generation di#11;ffers from traditional forms of generation in numerous ways though, motivating the need to reconsider the usual approaches to power system assessment and performance enhancement. The project has investigated the impact of wind generation on transient stability and voltage control, identifying and addressing issues at three distinct levels of the power system: 1) at the device level, the physical characteristics of wind turbine generators (WTGs) are quite unlike those of synchronous machines, 2) at the wind-farm level, the provision of reactive support is achieved through coordination of numerous dissimilar devices, rather than straightforward generator control, and 3) from a systems perspective, the location of wind-farms on the sub-transmission network, coupled with the variability inherent in their power output, can cause complex voltage control issues. The project has sought to develop a thorough understanding of the dynamic behaviour of type-3 WTGs, and in particular the WECC generic model. The behaviour of such models is governed by interactions between the continuous dynamics of state variables and discrete events associated with limits. It was shown that these interactions can be quite complex, and may lead to switching deadlock that prevents continuation of the trajectory. Switching hysteresis was proposed for eliminating deadlock situations. Various type-3 WTG models include control blocks that duplicate integrators. It was shown that this leads to non-uniqueness in the conditions governing steady-state, and may result in pre- and post-disturbance equilibria not coinciding. It also gives rise to a zero eigenvalue in the linearized WTG model. In order to eliminate the anomalous behaviour revealed through this investigation, WECC has now released a new generic model for type-3 WTGs. Wind-farms typically incorporate a variety of voltage control equipment including tapchanging transformers, switched capacitors, SVCs, STATCOMs and the WTGs themselves. The project has considered the coordinated control of this equipment, and has addressed a range of issues that arise in wind-farm operation. The #12;first concerns the ability of WTGs to meet reactive power requirements when voltage saturation in the collector network restricts the reactive power availability of individual generators. Secondly, dynamic interactions between voltage regulating devices have been investigated. It was found that under certain realistic conditions, tap-changing transformers may exhibit instability. In order to meet cost, maintenance, fault tolerance and other requirements, it is desirable for voltage control equipment to be treated as an integrated system rather than as independent devices. The resulting high-level scheduling of wind-farm reactive support has been investigated. In addressing this control problem, several forms of future information were considered, including exact future knowledge and stochastic predictions. Deterministic and Stochastic Dynamic Programming techniques were used in the development of control algorithms. The results demonstrated that while exact future knowledge is very useful, simple prediction methods yield little bene#12;fit. The integration of inherently variable wind generation into weak grids, particularly subtransmission networks that are characterized by low X=R ratios, aff#11;ects bus voltages, regulating devices and line flows. The meshed structure of these networks adds to the complexity, especially when wind generation is distributed across multiple nodes. A range of techniques have been considered for analyzing the impact of wind variability on weak grids. Sensitivity analysis, based on the power-flow Jacobian, was used to highlight sections of a system that are most severely a#11;ffected by wind-power variations. A continuation power flow was used to determine parameter changes that reduce the impact of wind-power variability. It was also used to explore interactions betw

Hiskens, Ian A.

2013-09-25T23:59:59.000Z

345

PHILOSOPHY HONORS NOMINATION FORM The Philosophy Department offers an honors program for outstanding students in the major. Majors who have a 3.7 GPA in  

E-Print Network [OSTI]

PHILOSOPHY HONORS NOMINATION FORM The Philosophy Department offers an honors program for outstanding students in the major. Majors who have a 3.7 GPA in philosophy (3.25 overall) at the end if philosophy honors are to be awarded. Honors students are expected to maintain an average of 3.7 or better

346

Brain Research Foundation: Scientific Innovations Award in Neuroscience The Brain Research Foundation has invited Wayne State University to nominate one senior faculty member  

E-Print Network [OSTI]

Brain Research Foundation: Scientific Innovations Award in Neuroscience The Brain Research Foundation has invited Wayne State University to nominate one senior faculty member to submit a Letter the LOI, it must be opened in Adobe Acrobat). To learn more about the Brain Research Foundation, click

Finley Jr., Russell L.

347

HERA-B Gas Systems The gas mixture, the gas volume of the corresponding detector and the required gas flow are given. All detectors are operating at nominal  

E-Print Network [OSTI]

HERA-B Gas Systems The gas mixture, the gas volume of the corresponding detector and the required gas flow are given. All detectors are operating at nominal pressure within a given tolerance p. The pipes connecting the external gas hut with the third floor of the electronics trailer are listed on page

348

Optimized Designs and Materials for Nanostructure Based Solar Cells  

E-Print Network [OSTI]

efficiency of solar panels and power to weight ratio insolar cells, there exist two basic processes to convert sunlight power topower to a load connected when charged by Sun. The typical output voltage of a silicon based solar

Shao, Qinghui

2009-01-01T23:59:59.000Z

349

Determining Outdoor CPV Cell Temperature: Preprint  

SciTech Connect (OSTI)

An accurate method is needed for determining cell temperature when measuring CPV modules outdoors. It has been suggested that cell temperature can be calculated though a procedure that shutters sunlight to the cells while measuring the transients in open-circuit voltage (Voc) and heat sink temperature. This paper documents application of this shutter procedure to multiple CPV modules at NREL. The challenges and limitations are presented along with an alternate approach to measuring CPV cell operating temperature.

Muller, M.; Deline, C.; Marion, B.; Kurtz, S.; Bosco, N.

2011-07-01T23:59:59.000Z

350

Voltage sensor with fiber Fabry-Perot interferometer  

E-Print Network [OSTI]

with smaller strain constants, a larger voltage must be applied to get a 2x round trip phase shift. Hence, a longer FFPI is needed to get higher resolution. 16 A plate type PZT was selected because it's more convenient to attach to a thermo-electric cooler... in electron-beam evaporation system, they can be spliced to uncoated fibers, which also have cleaved end surfaces. The basic configuration for this Siecor Model M 67 fusion splicer is shown in fig. 12. A electric arc is initiated between the electrodes...

Wann, Been-Huey

1992-01-01T23:59:59.000Z

351

Outdoor PV Module Degradation of Current-Voltage Parameters: Preprint  

SciTech Connect (OSTI)

Photovoltaic (PV) module degradation rate analysis quantifies the loss of PV power output over time and is useful for estimating the impact of degradation on the cost of energy. An understanding of the degradation of all current-voltage (I-V) parameters helps to determine the cause of the degradation and also gives useful information for the design of the system. This study reports on data collected from 12 distinct mono- and poly-crystalline modules deployed at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. Most modules investigated showed < 0.5%/year decrease in maximum power due to short-circuit current decline.

Smith, R. M.; Jordan, D. C.; Kurtz, S. R.

2012-04-01T23:59:59.000Z

352

Light-weight DC to very high voltage DC converter  

DOE Patents [OSTI]

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

1998-01-01T23:59:59.000Z

353

Light-weight DC to very high voltage DC converter  

DOE Patents [OSTI]

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

Druce, R.L.; Kirbie, H.C.; Newton, M.A.

1998-06-30T23:59:59.000Z

354

Light-induced voltage alteration for integrated circuit analysis  

DOE Patents [OSTI]

An apparatus and method are described for analyzing an integrated circuit (IC). The invention uses a focused light beam that is scanned over a surface of the IC to generate a light-induced voltage alteration (LIVA) signal for analysis of the IC. The LIVA signal may be used to generate an image of the IC showing the location of any defects in the IC; and it may be further used to image and control the logic states of the IC. The invention has uses for IC failure analysis, for the development of ICs, for production-line inspection of ICs, and for qualification of ICs. 18 figs.

Cole, E.I. Jr.; Soden, J.M.

1995-07-04T23:59:59.000Z

355

Methods, systems and apparatus for controlling third harmonic voltage when operating a multi-space machine in an overmodulation region  

SciTech Connect (OSTI)

Methods, system and apparatus are provided for controlling third harmonic voltages when operating a multi-phase machine in an overmodulation region. The multi-phase machine can be, for example, a five-phase machine in a vector controlled motor drive system that includes a five-phase PWM controlled inverter module that drives the five-phase machine. Techniques for overmodulating a reference voltage vector are provided. For example, when the reference voltage vector is determined to be within the overmodulation region, an angle of the reference voltage vector can be modified to generate a reference voltage overmodulation control angle, and a magnitude of the reference voltage vector can be modified, based on the reference voltage overmodulation control angle, to generate a modified magnitude of the reference voltage vector. By modifying the reference voltage vector, voltage command signals that control a five-phase inverter module can be optimized to increase output voltages generated by the five-phase inverter module.

Perisic, Milun; Kinoshita, Michael H; Ranson, Ray M; Gallegos-Lopez, Gabriel

2014-06-03T23:59:59.000Z

356

Low Voltage Operational Amplifier Design for Energy Harvesting Applications  

E-Print Network [OSTI]

: Background Power Management System Figure 1. A sediment microbial fuel cell (SMFC) with microbial anode.,"Batteryless, Wireless Sensor Powered by a Sediment Microbial Fuel Cell" Environ. Sci. Technol. 2008, vol. 42, pg 8591

Collins, Gary S.

357

Commercialization of Medium Voltage HTS Triax TM Cable Systems  

SciTech Connect (OSTI)

The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

Knoll, David

2012-12-31T23:59:59.000Z

358

Bi-directional power control system for voltage converter  

DOE Patents [OSTI]

A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals. 10 figs.

Garrigan, N.R.; King, R.D.; Schwartz, J.E.

1999-05-11T23:59:59.000Z

359

Bi-directional power control system for voltage converter  

DOE Patents [OSTI]

A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

Garrigan, Neil Richard (Niskayuna, NY); King, Robert Dean (Schenectady, NY); Schwartz, James Edward (Slingerlands, NY)

1999-01-01T23:59:59.000Z

360

Cathode Synthesis and Voltage Fade: Designed Solutions Based on Theory  

Broader source: Energy.gov [DOE]

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Broader source: Energy.gov [DOE]

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

362

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Broader source: Energy.gov (indexed) [DOE]

complete Timeline Budget Barriers Partners Overview * Barriers addressed: - A. Battery cost - C. Performance: Energy Density - E. Lifetime * Targets - prototype cells...

363

High Voltage Electrolytes for Li-ion Batteries  

Broader source: Energy.gov [DOE]

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

364

Over Voltage in a Multi-sectioned Solenoid during a Quenching  

SciTech Connect (OSTI)

Accurate analysis of over voltage in the superconducting solenoid during a quench is one of the bases for quench protection system design. Classical quench simulation methods can only give rough estimation of the over voltage within a magnet coil. In this paper, for multi-sectioned superconducting solenoid, based on the classical assumption of ellipsoidal normal zone, three-dimension al temperature results are mapped to the one-dimension of the wire, the temperature distribution along the wire and the resistances of each turn are obtained. The coil is treated as circuit comprised of turn resistances, turn self and mutual inductances. The turn resistive voltage, turn inductive voltage, and turn resultant voltage along the wire are calculated. As a result, maximum internal voltages, the layer-to-layer voltages and the turn-to-turn voltages are better estimated. Utilizing this method, the over voltage of a small solenoid and a large solenoid during quenching have been studied. The result shows that this method can well improve the over voltage estimate, especially when the coil is larger.

Guo, Xinglong; Wang, Li; Pan, Heng; Wu, Hong; Liu, Xiaokun; Chen, Anbin; Green, M.A.; Xu, F.Y.

2009-06-21T23:59:59.000Z

365

Control of Analyte Electrolysis in Electrospray Ionization Mass Spectrometry Using Repetitively Pulsed High Voltage  

SciTech Connect (OSTI)

Analyte electrolysis using a repetitively pulsed high voltage ion source was investigated and compared to that using a regular, continuously operating direct current high voltage ion source in electrospray ionization mass spectrometry. The extent of analyte electrolysis was explored as a function of the length and frequency of the high voltage pulse using the model compound reserpine in positive ion mode. Using +5 kV as the maximum high voltage amplitude, reserpine was oxidized to its 2, 4, 6 and 8-electron oxidation products when direct current high voltage was employed. In contrast, when using a pulsed high voltage, oxidation of reserpine was eliminated by employing the appropriate high voltage pulse length and frequency. This effect was caused by inefficient mass transport of the analyte to the electrode surface during the duration of the high voltage pulse and the subsequent relaxation of the emitter electrode/ electrolyte interface during the time period when the high voltage was turned off. This mode of ESI source operation allows for analyte electrolysis to be quickly and simply switched on or off electronically via a change in voltage pulse variables.

Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

2011-01-01T23:59:59.000Z

366

Experiment and Simulation of Dynamic Voltage Regulation in Multiple Distributed Energy Resources Systems  

SciTech Connect (OSTI)

Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction between the DEs is studied. The simulation results show the relationship between the voltages in the system and the reactive power required for the voltage regulation. Also, integrated voltage regulation (multiple DEs performing voltage regulation) can increase the voltage regulation capability of DEs and reduce the capital and operating costs.

Xu, Yan [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL; Rizy, D Tom [ORNL

2007-01-01T23:59:59.000Z

367

PEM fuel cell monitoring system  

DOE Patents [OSTI]

Method and apparatus for monitoring the performance of H.sub.2 --O.sub.2 PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H.sub.2 sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken.

Meltser, Mark Alexander (Pittsford, NY); Grot, Stephen Andreas (West Henrietta, NY)

1998-01-01T23:59:59.000Z

368

PEM fuel cell monitoring system  

DOE Patents [OSTI]

Method and apparatus are disclosed for monitoring the performance of H{sub 2}--O{sub 2} PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H{sub 2} sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken. 2 figs.

Meltser, M.A.; Grot, S.A.

1998-06-09T23:59:59.000Z

369

DECENTRALIZED CONTROL ARCHITECTURE FOR COUPLING MICROGRIDS INTO DISTRIBUTION NETWORKS 1 Task 1: Coupling Low-Voltage Microgrids into  

E-Print Network [OSTI]

DECENTRALIZED CONTROL ARCHITECTURE FOR COUPLING MICROGRIDS INTO DISTRIBUTION NETWORKS 1 Task 1: Coupling Low-Voltage Microgrids into Mid-Voltage Distribution Systems Zhao Wang, Student Member, IEEE-voltage (LV) microgrids. At the same time, reactive power is dispatched coordinatively so that voltage

Lemmon, Michael

370

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators  

E-Print Network [OSTI]

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators General Description The LM139 series consists of four independent precision voltage comparators with an offset voltage clock timers; multivibrators and high voltage digital logic gates. The LM139 series was designed

Lanterman, Aaron

371

Voltage-matched, monolithic, multi-band-gap devices  

SciTech Connect (OSTI)

Monolithic, tandem, photonic cells include at least a first semiconductor layer and a second semiconductor layer, wherein each semiconductor layer includes an n-type region, a p-type region, and a given band-gap energy. Formed within each semiconductor layer is a sting of electrically connected photonic sub-cells. By carefully selecting the numbers of photonic sub-cells in the first and second layer photonic sub-cell string(s), and by carefully selecting the manner in which the sub-cells in a first and second layer photonic sub-cell string(s) are electrically connected, each of the first and second layer sub-cell strings may be made to achieve one or more substantially identical electrical characteristics.

Wanlass, Mark W.; Mascarenhas, Angelo

2006-08-22T23:59:59.000Z

372

Voltage-Matched, Monolithic, Multi-Band-Gap Devices  

DOE Patents [OSTI]

Monolithic, tandem, photonic cells include at least a first semiconductor layer and a second semiconductor layer, wherein each semiconductor layer includes an n-type region, a p-type region, and a given band-gap energy. Formed within each semiconductor layer is a string of electrically connected photonic sub-cells. By carefully selecting the numbers of photonic sub-cells in the first and second layer photonic sub-cell string(s), and by carefully selecting the manner in which the sub-cells in a first and second layer photonic sub-cell string(s) are electrically connected, each of the first and second layer sub-cell strings may be made to achieve one or more substantially identical electrical characteristics.

Wanlass, M. W.; Mascarenhas, A.

2006-08-22T23:59:59.000Z

373

Control of fuel cell power output Federico Zenith, Sigurd Skogestad *  

E-Print Network [OSTI]

Control of fuel cell power output Federico Zenith, Sigurd Skogestad * Department of Chemical A simplified dynamic model for fuel cells is developed, based on the concept of instantaneous characteristic, which is the set of values of current and voltage that a fuel cell can reach instantaneously

Skogestad, Sigurd

374

SSRLUO EC Ballot Nominations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 -the Mid-Infrared0 ResourceAwards SAGE AwardsNA-00197-1USERS' ORGANIZATION CHARTER

375

COR Nomination Form  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 <Ones |Laboratory, JuneDid y ou knowofPRGMCOR

376

Fellows' Nominations and Selections  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-Series toESnet4:Epitaxial ThinFORFALL NEWS ROCKYGasDirectory Fellows

377

Fellows' Prize Nominations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-Series toESnet4:Epitaxial ThinFORFALL NEWS ROCKYGasDirectory

378

Pulsed voltage electrospray ion source and method for preventing analyte electrolysis  

DOE Patents [OSTI]

An electrospray ion source and method of operation includes the application of pulsed voltage to prevent electrolysis of analytes with a low electrochemical potential. The electrospray ion source can include an emitter, a counter electrode, and a power supply. The emitter can include a liquid conduit, a primary working electrode having a liquid contacting surface, and a spray tip, where the liquid conduit and the working electrode are in liquid communication. The counter electrode can be proximate to, but separated from, the spray tip. The power system can supply voltage to the working electrode in the form of a pulse wave, where the pulse wave oscillates between at least an energized voltage and a relaxation voltage. The relaxation duration of the relaxation voltage can range from 1 millisecond to 35 milliseconds. The pulse duration of the energized voltage can be less than 1 millisecond and the frequency of the pulse wave can range from 30 to 800 Hz.

Kertesz, Vilmos (Knoxville, TN); Van Berkel, Gary (Clinton, TN)

2011-12-27T23:59:59.000Z

379

Bright and fast voltage reporters across the visible spectrum via electrochromic FRET (eFRET)  

E-Print Network [OSTI]

We present a palette of brightly fluorescent genetically encoded voltage indicators (GEVIs) with excitation and emission peaks spanning the visible spectrum, sensitivities from 6 - 10% Delta F/F per 100 mV, and half-maximal response times from 1 - 7 ms. A fluorescent protein is fused to an Archaerhodopsin-derived voltage sensor. Voltage-induced shifts in the absorption spectrum of the rhodopsin lead to voltage-dependent nonradiative quenching of the appended fluorescent protein. Through a library screen, we identified linkers and fluorescent protein combinations which reported neuronal action potentials in cultured rat hippocampal neurons with a single-trial signal-to-noise ratio from 6.6 to 11.6 in a 1 kHz imaging bandwidth at modest illumination intensity. The freedom to choose a voltage indicator from an array of colors facilitates multicolor voltage imaging, as well as combination with other optical reporters and optogenetic actuators.

Zou, Peng; Douglass, Adam D; Hochbaum, Daniel R; Brinks, Daan; Werley, Christopher A; Harrison, D Jed; Campbell, Robert E; Cohen, Adam E

2014-01-01T23:59:59.000Z

380

Nanowire-based ternary transistor by threshold-voltage manipulation  

SciTech Connect (OSTI)

We report on a ternary device consisting of two nanowire channels that have different threshold voltage (V{sub th}) values and show that three current stages can be produced. A microscale laser-beam shot was utilized to selectively anneal the nanowire channel area to be processed, and the amount of V{sub th} shift could be controlled by adjusting the laser wavelength. Microscale laser annealing process could control V{sub th} of the individual nanowire transistors while maintaining the other parameters the constant, such as the subthreshold slope, on–off current ratio, and mobility. This result could provide a potential for highly integrated and high-speed ternary circuits.

Han, Junebeom; Lim, Taekyung; Bong, Jihye; Seo, Keumyoung; Ju, Sanghyun, E-mail: shju@kgu.ac.kr [Department of Physics, Kyonggi University, Suwon, Gyeonggi-Do 443-760 (Korea, Republic of); Kim, Sunkook [Department of Electronics and Radio Engineering, Kyung Hee University, Yongin, Gyeonggi-Do 446-701 (Korea, Republic of)

2014-04-07T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Probabilistic Vulnerability Assessment Based on Power Flow and Voltage Distribution  

SciTech Connect (OSTI)

Risk assessment of large scale power systems has been an important problem in power system reliability study. Probabilistic technique provides a powerful tool to solve the task. In this paper, we present the results of a study on probabilistic vulnerability assessment on WECC system. Cumulant based expansion method is applied to obtain the probabilistic distribution function (PDF) and cumulative distribution function (CDF) of power flows on transmission lines and voltage. Overall risk index based on the system vulnerability analysis is calculated using the WECC system. The simulation results based on WECC system is used to demonstrate the effectiveness of the method. The methodology can be applied to the risk analysis on large scale power systems.

Ma, Jian; Huang, Zhenyu; Wong, Pak C.; Ferryman, Thomas A.

2010-04-30T23:59:59.000Z

382

Voltage flicker prediction for two simultaneously operated ac arc furnaces  

SciTech Connect (OSTI)

An EMTP-based arc furnace model was developed for evaluation of flicker concerns associated with supplying a large integrated steel mill as they go from one to two furnace operation and as system changes are implemented that will affect the short circuit capacity at the 230 kV power supply substation. The model includes a dynamic arc representation which is designed to be characteristic of the initial portions of the melt cycle when the arc characteristics are the most variable (worst flicker conditions). The flicker calculations are verified using previous measurements with one furnace operation. Flicker simulations were then performed to evaluate a variety of different possible system strengths with both one and two furnaces in operation. The primary flicker measure used for this study is the unweighted rms value of the fluctuation envelope, expressed as a percentage of the rms line-to-ground voltage magnitude.

Tang, L. [ABB Power T and D Co., Inc., Raleigh, NC (United States)] [ABB Power T and D Co., Inc., Raleigh, NC (United States); Kolluri, S. [Entergy Services, New Orleans, LA (United States)] [Entergy Services, New Orleans, LA (United States); McGranaghan, M.F. [Electrotek Concepts, Inc., Knoxville, TN (United States)] [Electrotek Concepts, Inc., Knoxville, TN (United States)

1997-04-01T23:59:59.000Z

383

Voltage spike detection in high field superconducting accelerator magnets  

SciTech Connect (OSTI)

A measurement system for the detection of small magnetic flux changes in superconducting magnets, which are due to either mechanical motion of the conductor or flux jump, has been developed at Fermilab. These flux changes are detected as small amplitude, short duration voltage spikes, which are {approx}15mV in magnitude and lasts for {approx}30 {micro}sec. The detection system combines an analog circuit for the signal conditioning of two coil segments and a fast data acquisition system for digitizing the results, performing threshold detection, and storing the resultant data. The design of the spike detection system along with the modeling results and noise analysis will be presented. Data from tests of high field Nb{sub 3}Sn magnets at currents up to {approx}20KA will also be shown.

Orris, D.F.; Carcagno, R.; Feher, S.; Makulski, A.; Pischalnikov, Y.M.; /Fermilab

2004-12-01T23:59:59.000Z

384

Effect of high-voltage nanosecond pulses on complex plasmas  

SciTech Connect (OSTI)

Influence of high-voltage (1-11 kV) pulses of nanosecond (20 ns) duration on microparticles levitating in a rf plasma is studied. It is shown that the pulses produce significant influence on the plasma, causing perturbations with the relaxation time of the order of 10{sup -4} s. This time is sufficient for the microparticle to acquire significant kinetic energy. Application of repetitive pulses leads to the vertical oscillations of the microparticles. Clusters, consisting of small number of microparticles, exhibit parametric instabilities of horizontal modes under the effect of repetitive pulses. It was shown that the parametric instability is caused by the vertical oscillations of the microparticles in the nonuniform environment of the sheath.

Pustylnik, M. Y.; Ivlev, A. V.; Thomas, H. M.; Morfill, G. E. [Max-Planck-Institut fuer Extraterrestrische Physik, Giessenbachstrasse, 85741 Garching (Germany); Vasilyak, L. M.; Vetchinin, S. P.; Polyakov, D. N.; Fortov, V. E. [Joint Institute for High Temperatures, Russian Academy of Sciences, Izhorskaya 13/19, 125412 Moscow (Russian Federation)

2009-11-15T23:59:59.000Z

385

High-speed, sub-pull-in voltage MEMS switching.  

SciTech Connect (OSTI)

We have proposed and demonstrated MEMS switching devices that take advantage of the dynamic behavior of the MEMS devices to provide lower voltage actuation and higher switching speeds. We have explored the theory behind these switching techniques and have demonstrated these techniques in a range of devices including MEMS micromirror devices and in-plane parallel plate MEMS switches. In both devices we have demonstrated switching speeds under one microsecond which has essentially been a firm limit in MEMS switching. We also developed low-loss silicon waveguide technology and the ability to incorporate high-permittivity dielectric materials with MEMS. The successful development of these technologies have generated a number of new projects and have increased both the MEMS switching and optics capabilities of Sandia National Laboratories.

Spahn, Olga Blum; Brewer, Steven; Olsson, Roy H.; Bogart, Gregory R.; Luck, David L.; Watts, Michael R.; Shaw, Michael J.; Nielson, Gregory N.; Resnick, Paul James; Tigges, Christopher P.; Grossetete, Grant David

2008-01-01T23:59:59.000Z

386

High-voltage atmospheric breakdown across intervening rutile dielectrics.  

SciTech Connect (OSTI)

This report documents work conducted in FY13 on electrical discharge experiments performed to develop predictive computational models of the fundamental processes of surface breakdown in the vicinity of high-permittivity material interfaces. Further, experiments were conducted to determine if free carrier electrons could be excited into the conduction band thus lowering the effective breakdown voltage when UV photons (4.66 eV) from a high energy pulsed laser were incident on the rutile sample. This report documents the numerical approach, the experimental setup, and summarizes the data and simulations. Lastly, it describes the path forward and challenges that must be overcome in order to improve future experiments for characterizing the breakdown behavior for rutile.

Williamson, Kenneth Martin; Simpson, Sean; Coats, Rebecca Sue; Jorgenson, Roy Eberhardt; Hjalmarson, Harold Paul; Pasik, Michael Francis

2013-09-01T23:59:59.000Z

387

System and method for floating-substrate passive voltage contrast  

DOE Patents [OSTI]

A passive voltage contrast (PVC) system and method are disclosed for analyzing ICs to locate defects and failure mechanisms. During analysis a device side of a semiconductor die containing the IC is maintained in an electrically-floating condition without any ground electrical connection while a charged particle beam is scanned over the device side. Secondary particle emission from the device side of the IC is detected to form an image of device features, including electrical vias connected to transistor gates or to other structures in the IC. A difference in image contrast allows the defects or failure mechanisms be pinpointed. Varying the scan rate can, in some instances, produce an image reversal to facilitate precisely locating the defects or failure mechanisms in the IC. The system and method are useful for failure analysis of ICs formed on substrates (e.g. bulk semiconductor substrates and SOI substrates) and other types of structures.

Jenkins, Mark W. (Albuquerque, NM); Cole, Jr., Edward I. (Albuquerque, NM); Tangyunyong, Paiboon (Albuquerque, NM); Soden, Jerry M. (Placitas, NM); Walraven, Jeremy A. (Albuquerque, NM); Pimentel, Alejandro A. (Albuquerque, NM)

2009-04-28T23:59:59.000Z

388

Summary of multiterminal high-voltage direct current transmission technology  

SciTech Connect (OSTI)

This report summarizes the present state of multiterminal (MT) high-voltage direct current (HVDC) power transmission. The purpose is to reassess the need for HVDC circuit breakers and to identify needed research for MT HVDC. The fundamentals of this technology are presented, and previous research and development is reviewed. Although no MT HVDC systems have yet been built, many concepts have been proposed. Some require a dc breaker, and others do not. Both options have advantages and disadvantages for various applications, so the selection will depend on the proposed application. Research is needed to define operating characteristics of various MT HVDC systems. In some applications, dc breakers will be useful, so research into HVDC interruption should continue. Also, dc fault detection and control algorithms for MT systems should be studied.

Biggs, R.B.; Jewell, W.T.

1984-05-01T23:59:59.000Z

389

Sacramento Area Voltage Support Final Environmental Impact Statement  

SciTech Connect (OSTI)

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the National Environmental Policy Act (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: (1) Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; (2) Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and (3) Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2003-09-19T23:59:59.000Z

390

Sacramento Area Voltage Support Draft Environmental Impact Statement  

SciTech Connect (OSTI)

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the ''National Environmental Policy Act'' (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2002-11-15T23:59:59.000Z

391

Effect of Hysteresis on Measurements of Thin-Film Cell Performance  

SciTech Connect (OSTI)

Transient or hysteresis effects in polycrystalline thin film CdS/CdTe cells are a function of pre-measurement voltage bias and whether Cu is introduced as an intentional dopant during back contact fabrication. When Cu is added, the current-density (J) vs. voltage (V) measurements performed in a reverse-to-forward voltage direction will yield higher open-circuit voltage (Voc), up to 10 mV, and smaller short-circuit current density (Jsc), by up to 2 mA/cm2, relative to scanning voltage in a forward-to-reverse direction. The variation at the maximum power point, Pmax, is however small. The resulting variation in FF can be as large as 3%. When Cu is not added, hysteresis in both Voc and Jsc is negligible however Pmax hysteresis is considerably greater. This behavior corroborates observed changes in depletion width, Wd, derived from capacitance (C) vs voltage (V) scans. Measured values of Wd are always smaller in reverse-to-forward voltage scans, and conversely, larger in the forward-to-reverse voltage direction. Transient ion drift (TID) measurements performed on Cu-containing cells do not show ionic behavior suggesting that capacitance transients are more likely due to electronic capture-emission processes. J-V curve simulation using Pspice shows that increased transient capacitance during light-soak stress at 100 degrees C correlates with increased space-charge recombination. Voltage-dependent collection however was not observed to increase with stress in these cells.

Albin, D.; del Cueto, J.

2011-03-01T23:59:59.000Z

392

A new technique to reject dc-link voltage ripple in PWM inverters  

E-Print Network [OSTI]

to acknowledge the support of my husband and parents. TA. BLE OF CONTENTS CHAPTER I INTRODUCTION Page I. l Inverter Power Supplies 1. 2 Output Voltage Control 1. 2. 1 Control Of Voltage Supplied To The Inverter I. 2. 2 Control Of Voltage Within... and output of Stage 3 78 34 Exact solution of the switching angle trajectories for harmonic elimination with voltage control (M). 85 CHAPTER I INTRODUCTION Finding ways to control the flow of electricity has been a. goal of inventors and scientists...

Shireen, Wajiha

1990-01-01T23:59:59.000Z

393

The design of an A-C voltage regulator using a Wein Bridge detector  

E-Print Network [OSTI]

equipment, which in turn demands a mox'e closely regulated power supply. In satisfying these demands there have been many kinds of voltage regulators designed, constructed, and needs A voltage regulator oonsists essentially of two pax'ts, the "detectox...-V, 424-8, 470 3, 499-503 1950 4. Patchett, G. N. , "The Theory of Nonlinear Bridge Circuit Applied to Voltage Stabilizers, " J. I . E. E . , Vol. 93, Pt. III, p. 18 (1948). 5. Choudbury, J. K. t Das Gupta, S. C. , and Sen, P. C, , "An A-C Voltage...

Brown, Richard True

2012-06-07T23:59:59.000Z

394

High voltage bus and auxiliary heater control system for an electric or hybrid vehicle  

DOE Patents [OSTI]

A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

Murty, Balarama Vempaty (West Bloomfield, MI)

2000-01-01T23:59:59.000Z

395

February 2008 Rev 21 1/49 Very low drop voltage regulators with inhibit  

E-Print Network [OSTI]

. In the three terminal configuration the device has the same electrical performance, but is fixed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 4. Dropout voltage vs output current

Berns, Hans-Gerd

396

Integration of offshore wind farms through High Voltage Direct Current networks.  

E-Print Network [OSTI]

??The integration of offshore wind farms through Multi Terminal DC (MTDC) networks into the GB network was investigated. The ability of Voltage Source Converter (VSC)… (more)

Livermore, Luke

2013-01-01T23:59:59.000Z

397

Solid State NMR Studies and Local Structure of Voltage Fade Materials  

Broader source: Energy.gov (indexed) [DOE]

with the Voltage Fade Team Michael Slater, Jason Croy, Kevin Gallagher, Christopher Johnson, Yang Ren DOE Vehicle Technologies Program Annual Merit Review Arlington, VA May 13 -...

398

Consideration of 34. 5 KV as an in-plant voltage for a large industrial user  

SciTech Connect (OSTI)

Traditionally, the in-plant distribution voltage for a large refinery or petrochemical complex has been 13.8 kV. Selection of this voltage level was dictated primarily by economic factors, simply because in most cases the magnitude of the loads or the lengths of the feeders did not produce sufficient savings to compensate for the costlier higher voltage switchgear. This paper presents some engineering and cost considerations for distribution at 34.5 kV and attempts to show that this voltage level is both economically and technically feasible for large electrical systems.

Niculescu, T.D.; Regan, R.R.

1983-09-01T23:59:59.000Z

399

E-Print Network 3.0 - active load voltage Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Page: << < 1 2 3 4 5 > >> 41 Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power Filter Applications Summary: Performance Analysis of a...

400

Theory and practice of dynamic voltage/frequency scaling in the high performance computing environment.  

E-Print Network [OSTI]

?? This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We… (more)

Rountree, Barry Louis

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Electric Field Calculations on Dry-Type Medium Voltage Current Transformers.  

E-Print Network [OSTI]

??This research presents potential and electric field calculations on medium voltage (MV) epoxy insulated outdoor current transformers (CTs) using a numeri-cal calculation approach. Two designs… (more)

Lakshmichand Jain, Sandeep Kumar

2012-01-01T23:59:59.000Z

402

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage...  

Broader source: Energy.gov (indexed) [DOE]

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage Princeton Power Systems (TRL 5 6...

403

Sharp interface and voltage conservation in the phase field method  

E-Print Network [OSTI]

electrical wave is anisotropic, and cardiac tissue is made up of cells with ...... of the heart,” Proceedings of the 16th Annual Conference on Engineering in ...

2007-07-14T23:59:59.000Z

404

Method of improving fuel cell performance by removing at least one metal oxide contaminant from a fuel cell electrode  

DOE Patents [OSTI]

A method of removing contaminants from a fuel cell catalyst electrode. The method includes providing a getter electrode and a fuel cell catalyst electrode having at least one contaminant to a bath and applying a voltage sufficient to drive the contaminant from the fuel cell catalyst electrode to the getter electrode. Methods of removing contaminants from a membrane electrode assembly of a fuel cell and of improving performance of a fuel cell are also provided.

Kim, Yu Seung (Los Alamos, NM); Choi, Jong-Ho (Los Alamos, NM); Zelenay, Piotr (Los Alamos, NM)

2009-08-18T23:59:59.000Z

405

Energy Resolved High Resolution Dynamic E-Cell Materials Research. Final Report  

SciTech Connect (OSTI)

The purpose of this project was to develop in situ materials reaction observation capability in an intermediate voltage high resolution transmission electron microscope. To accomplish this we purchased a GATAN imaging energy filter system, a hot stage, and designed and constructed an environmental cell and real time television image recording system, and installed this equipment on our EM 430 intermediate voltage electron microscope.

Carpenter, Ray; Sharma, Renu; Mayer, James

2000-05-16T23:59:59.000Z

406

FUEL CELL R&D AND DEMONSTRATION Robert E. Fields, E. John Rowley,  

E-Print Network [OSTI]

) offered by fuel cells may more than compensate for higher cost and fuel supply issues. Figure 1. A Victory, active/passive PEM fuel cell stack and a 24-volt, 3.4 ampere-hour sealed lead acid battery pack (4 x LC Tank DC-DC Converter Batteries Speed Controller Traction Motor Fuel Cell Stack MAIN BOARD Cell Voltages

407

A LOW POWER SCHEDULING SCHEME WITH RESOURCES OPERATING AT MULTIPLE VOLTAGES  

E-Print Network [OSTI]

A LOW POWER SCHEDULING SCHEME WITH RESOURCES OPERATING AT MULTIPLE VOLTAGES Ali Manzak and Chaitali Tempe, AZ 85287­5706 istanbul@asu.edu, chaitali@asu.edu ABSTRACT This paper presents a new resource the resources operate at multi­ ple voltages. The scheduling scheme is list based. In each control cycle

Kambhampati, Subbarao

408

Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power System  

E-Print Network [OSTI]

Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power collapse will occurs in a wind power system is discussed next. The method of power flow calculation is the specific analysis of a given simplified wind power system. Keywords--voltage collapse; Newton

Lavaei, Javad

409

Voltage Control of Distribution Networks with Distributed Generation using Reactive Power  

E-Print Network [OSTI]

Voltage Control of Distribution Networks with Distributed Generation using Reactive Power to control voltage of distribution networks with DG using reactive power compensation approach. In this paper profile within the specified limits, it is essential to regulate the reactive power of the compensators

Pota, Himanshu Roy

410

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal Dutta  

E-Print Network [OSTI]

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal}@eecs.umich.edu culler@cs.berkeley.edu Abstract AC power meters require both voltage and current to be sampled physical proximity and fed into a single power metering de- vice. In this paper, we explore the viability

Dutta, Prabal

411

Mitigation of Voltage and Current Harmonics in Grid-Connected Microgrids  

E-Print Network [OSTI]

Mitigation of Voltage and Current Harmonics in Grid-Connected Microgrids Mehdi Savaghebi1 , Josep M-connected microgrids. Two modes of compensation are considered, i.e. voltage and current compensation modes-electronic interface converter to the utility grid or microgrid. Microgrid is a local grid consisting of DGs, energy

Vasquez, Juan Carlos

412

Wind Farm Reactive Support and Voltage Control Daniel F. Opila Abdi M. Zeynu Ian A. Hiskens  

E-Print Network [OSTI]

Wind Farm Reactive Support and Voltage Control Daniel F. Opila Abdi M. Zeynu Ian A. Hiskens Abstract--Wind farms typically contain a variety of voltage control equipment including tap or wind farm; it is desirable to treat all the equipment as an integrated system rather than independent

Hiskens, Ian A.

413

Supply Voltage Degradation Aware Analytical Placement Andrew B. Kahng Bao Liu Qinke Wang  

E-Print Network [OSTI]

% performance degradation, and the effect is super-linear [22]. Therefore, power/ground Work partially supported along a supply cur- rent path, and (2) adding large decoupling capacitors close to supply voltage supply voltage drop). For high frequency de- signs, a number of decoupling capacitors need to be added

Liu, Bao

414

LM386 Low Voltage Audio Power Amplifier Literature Number: SNAS545A  

E-Print Network [OSTI]

LM386 LM386 Low Voltage Audio Power Amplifier Literature Number: SNAS545A #12;LM386 Low Voltage Audio Power Amplifier General Description The LM386 is a power amplifier designed for use in low volt, making the LM386 ideal for battery operation. Features n Battery operation n Minimum external parts n

Ravikumar, B.

415

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators  

E-Print Network [OSTI]

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators General Description The LM clock timers; multivibrators and high voltage digital logic gates. The LM193 series was designed to directly interface with TTL and CMOS. When operated from both plus and minus power supplies, the LM193

Lanterman, Aaron

416

A New Bifurcation Analysis for Power System Dynamic Voltage Stability Studies  

E-Print Network [OSTI]

a specific system configuration and the operation condition. For a power system, the typical state variables are the time dependent generator voltages (For different generator models, the variables of generator voltages as the variables of the exciter, speed governor and so on; sometimes the dynamics of the load behavior will also

417

Impact of High Wind Penetration on the Voltage Profile of Distribution Systems  

E-Print Network [OSTI]

of wind generator the voltage of the system may become lower than acceptable voltage level due and wind generator is presented. Simulation results are given in Section III which shows the impact of high--In this paper, simulation results showing the effect of lower and higher penetration of distributed wind

Pota, Himanshu Roy

418

Energy Aware Dynamic Voltage and Frequency Selection for Real-Time Systems with Energy Harvesting  

E-Print Network [OSTI]

Energy Aware Dynamic Voltage and Frequency Selection for Real-Time Systems with Energy Harvesting}@binghamton.edu Abstract In this paper, an energy aware dynamic voltage and frequency selection (EA-DVFS) algorithm energy and the harvested energy in a future duration. Specifically, if the system has sufficient energy

Qiu, Qinru

419

A static voltage-current characteristic for the low current DC arc  

E-Print Network [OSTI]

in the literature. Evaluated using the F-statistic, the best model, with a standard error of less than 3V , was a voltage source, opposed to the system voltage, dependent only on arc length. Current only influenced arc lifetime. Varc=l3v+l68v/inch*arc length...

Moores, Gregory Lee

1998-01-01T23:59:59.000Z

420

A theoretical study of the incandescent filament lamp performance under voltage flicker  

SciTech Connect (OSTI)

Incandescent filament lamp flicker, produced by voltage fluctuation, is a power quality problem that caused engineering concern since the onset of electrical illumination technology. The flicker phenomenon was analyzed and explained in early studies. Standards dealing with acceptable flicker levels are well known, nevertheless, today the discussion about flicker continues to be a top priority topic due to the fact that steady-state and transient voltage waveform distortion is a growing problem in low and medium voltage systems. In many situations voltage flicker is caused by subharmonics and interharmonics of voltage. Cycloconverters, welders and arc furnaces, eccentrically operating tools and integral cycle controlled power equipment are notorious for producing voltage flicker. The goal of this paper is to provide solid mathematical basis for the analytical modeling of incandescent filament lamp flicker when the voltage is nonsinusoidal. A mathematical model that enables the evaluation of the luminous flux modulation caused by noninteger harmonics (subharmonics and interharmonics) is presented. Three situations are detailed: square-wave voltage modulation, sinusoidal modulation and the case of noninteger harmonics with nearly contiguous frequencies.

Peretto, L. [Univ. of Bologna (Italy)] [Univ. of Bologna (Italy); Emanuel, A.E. [Worcester Polytechnic Inst., MA (United States)] [Worcester Polytechnic Inst., MA (United States)

1997-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions  

E-Print Network [OSTI]

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 19-1 High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 1. DC Properties of Modern Filled Epoxy Insulation Academic and Research Staff Dr. Chathan Cooke Sponsor

422

VOLTAGE COLLAPSE AND TRANSIENT ENERGY FUNCTION ANALYSES OF AC/DC SYSTEMS  

E-Print Network [OSTI]

for power system dynamic models, including a third order representation of high voltage direct current (HVDC power limits, HVDC firing angle limits and voltage dependent current order limits (VDCOL) are shown the derivation of individual component Lyapunov functions for simplified models of HVDC links connected

Cañizares, Claudio A.

423

DECENTRALIZED VOLTAGE CONTROL TO MINIMIZE DISTRIBUTION LOSSES IN AN ISLANDED MICROGRID  

E-Print Network [OSTI]

power sources and energy storage systems such as batteries requires new power and voltage control-time voltage control algorithm that minimizes power losses for a microgrid supported by inverter based Microgrids can bring electricity power to rural communities or isolated military forward operation bases

Peng, Huei

424

A Smart Grid Voltage Sag Detector using an EEMD-Based Approach  

E-Print Network [OSTI]

A Smart Grid Voltage Sag Detector using an EEMD-Based Approach Yassine Amirat, Member, IEEE and Mohamed Benbouzid, Senior Member, IEEE Abstract--Smart grids have become a focal point in renewable energy detection in smart grids. Index Terms--Smart grid, voltage sag detection, power quality (PQ), ensemble

Paris-Sud XI, Université de

425

An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context  

E-Print Network [OSTI]

An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context Yassine Amirat1,2 , Mohamed Benbouzid2 , Tianzhen Wang3 and Sylvie Turri2 Abstract­Smart grids have become, using the instantaneous power for voltage sags detection in smart grids. Copyright © 2013 Praise Worthy

Brest, Université de

426

Evaluation of Insulation Systems for the Optimal Design of High Voltage Pulse Transformers  

E-Print Network [OSTI]

This paper presents a study for the design of the insulation systems of high voltage pulse transformer based on experimental tests and numerical simulations. Data of high voltage tests on solid and liquid insulation materials are presented and discussed. The understanding of each part of the insulation is supported by electrostatic fields simulations.

Sylvain, Candolfi; Davide, Aguglia; Philippe, Viarouge; Jürgen, Biela; Jerome, Cros

2015-01-01T23:59:59.000Z

427

A New Thermal-Conscious System-Level Methodology for Energy-Efficient Processor Voltage Selection  

E-Print Network [OSTI]

A New Thermal-Conscious System-Level Methodology for Energy-Efficient Processor Voltage Selection a thermal-conscious system-level methodology to make energy-efficient voltage selection (VS) for nanometer), thermal resistance, are integrated and considered in our system models, and their impacts on energy

Wang, Yu

428

Mechanisms of deflagration-to-detonation transition under initiation by high-voltage nanosecond discharges  

SciTech Connect (OSTI)

An experimental study of detonation initiation in a stoichiometric propane-oxygen mixture by a high-voltage nanosecond gas discharge was performed in a detonation tube with a single-cell discharge chamber. The discharge study performed in this geometry showed that three modes of discharge development were realized under the experimental conditions: a spark mode with high-temperature channel formation, a streamer mode with nonuniform gas excitation, and a transient mode. Under spark and transient initiation, simultaneous ignition inside the discharge channel occurred, forming a shock wave and leading to a conventional deflagration-to-detonation transition (DDT) via an adiabatic explosion. The DDT length and time at 1 bar of initial pressure in the square smooth tube with a 20-mm transverse size amounted to 50 mm and 50{mu}s, respectively. The streamer mode of discharge development at an initial pressure of 1 bar resulted in nonuniform mixture excitation and a successful DDT via a gradient mechanism, which was confirmed by high-speed time resolved ICCD imaging. The gradient mechanism implied a longer DDT time of 150{mu}s, a DDT run-up distance of 50 mm, and an initiation energy of 1 J, which is two orders of magnitude less than the direct initiation energy for a planar detonation under these conditions. (author)

Rakitin, Aleksandr E.; Starikovskii, Andrei Yu. [Physics of Nonequilibrium Systems Lab, Moscow Institute of Physics and Technology, 9 Institutski Lane, Dolgoprudny 141700 (Russian Federation)

2008-10-15T23:59:59.000Z

429

Characterization of Multicrystalline Silicon Modules with System Bias Voltage Applied in Damp Heat  

SciTech Connect (OSTI)

As it is considered economically favorable to serially connect modules to build arrays with high system voltage, it is necessary to explore potential long-term degradation mechanisms the modules may incur under such electrical potential. We performed accelerated lifetime testing of multicrystalline silicon PV modules in 85 degrees C/ 85% relative humidity and 45 degrees C/ 30% relative humidity while placing the active layer in either positive or negative 600 V bias with respect to the grounded module frame. Negative bias applied to the active layer in some cases leads to more rapid and catastrophic module power degradation. This is associated with significant shunting of individual cells as indicated by electroluminescence, thermal imaging, and I-V curves. Mass spectroscopy results support ion migration as one of the causes. Electrolytic corrosion is seen occurring with the silicon nitride antireflective coating and silver gridlines, and there is ionic transport of metallization at the encapsulant interface observed with damp heat and applied bias. Leakage current and module degradation is found to be highly dependent upon the module construction, with factors such as encapsulant and front glass resistivity affecting performance. Measured leakage currents range from about the same seen in published reports of modules deployed in Florida (USA) and is accelerated to up to 100 times higher in the environmental chamber testing.

Hacke, P.; Kempe, M.; Terwilliger, K.; Glick, S.; Call, N.; Johnston, S.; Kurtz, S.

2011-07-01T23:59:59.000Z

430

Switch contact device for interrupting high current, high voltage, AC and DC circuits  

DOE Patents [OSTI]

A high voltage switch contact structure capable of interrupting high voltage, high current AC and DC circuits. The contact structure confines the arc created when contacts open to the thin area between two insulating surfaces in intimate contact. This forces the arc into the shape of a thin sheet which loses heat energy far more rapidly than an arc column having a circular cross-section. These high heat losses require a dramatic increase in the voltage required to maintain the arc, thus extinguishing it when the required voltage exceeds the available voltage. The arc extinguishing process with this invention is not dependent on the occurrence of a current zero crossing and, consequently, is capable of rapidly interrupting both AC and DC circuits. The contact structure achieves its high performance without the use of sulfur hexafluoride.

Via, Lester C.; Witherspoon, F. Douglas; Ryan, John M.

2005-01-04T23:59:59.000Z

431

Performance of MicroLink Cells Developed Under Navy STTR: Cooperative Research and Development Final Report, CRADA Number CRD-11-426  

SciTech Connect (OSTI)

Evaluate MicroLink cells as a function of temperature and spectral irradiance following the teams' standard procedures. These measurements will include the standard procedures for evaluating multijunction cells including quantum efficiency measurements and current versus voltage measurements.

Emery, K.

2013-06-01T23:59:59.000Z

432

Low Voltage High Precision Spatial Light ModulatorsFinal Report  

SciTech Connect (OSTI)

The goal of this project was to make LLNL a leader in Spatial Light Modulators (SLMs) by developing the technology that will be needed by the next generation of SLMs. We would use new lower voltage actuators and bond those actuators directly to controlling circuitry to break the fundamental limitations that constrain current SLM technology. This three-year project was underfunded in the first year and not funded in the second year. With the funding that was available, we produced actuators and designs for the controlling circuitry that would have been integrated in the second year. Spatial light modulators (SLMs) are arrays of tiny movable mirrors that modulate the wave-fronts of light. SLMs can correct aberrations in incoming light for adaptive optics or modulate light for beam control, optical communication and particle manipulation. MicroElectroMechanical Systems (MEMS) is a technology that utilizes the microfabrication tools developed by the semiconductor industry to fabricate a wide variety of tiny machines. The first generation of MEMS SLMs have improved the functionality of SLMs while drastically reducing per pixel cost making arrays on the order of 1000 pixels readily available. These MEMS SLMs however are limited by the nature of their designs to be very difficult to scale above 1000 pixels and have very limited positioning accuracy. By co-locating the MEMS mirrors with CMOS electronics, we will increase the scalability and positioning accuracy. To do this we will have to make substantial advances in SLM actuator design, and fabrication.

Papavasiliou, A P

2005-02-09T23:59:59.000Z

433

High voltage power supply with modular series resonant inverters  

DOE Patents [OSTI]

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

Dreifuerst, Gary R. (Livermore, CA); Merritt, Bernard T. (Livermore, CA)

1995-01-01T23:59:59.000Z

434

High voltage power supply with modular series resonant inverters  

DOE Patents [OSTI]

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.

Dreifuerst, G.R.; Merritt, B.T.

1995-07-18T23:59:59.000Z

435

Electrolytes and Separators for High Voltage Li Ion Cells | Department of  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE: ECMConstruction andElectrolytes | DepartmentEnergy 2

436

Electrolytes and Separators for High Voltage Li Ion Cells | Department of  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE: ECMConstruction andElectrolytes | DepartmentEnergy

437

An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.  

SciTech Connect (OSTI)

References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

Litzenberger, Wayne; Lava, Val

1994-08-01T23:59:59.000Z

438

Electrochemical sensor for monitoring electrochemical potentials of fuel cell components  

DOE Patents [OSTI]

An electrochemical sensor comprised of wires, a sheath, and a conduit can be utilized to monitor fuel cell component electric potentials during fuel cell shut down or steady state. The electrochemical sensor contacts an electrolyte reservoir plate such that the conduit wicks electrolyte through capillary action to the wires to provide water necessary for the electrolysis reaction which occurs thereon. A voltage is applied across the wires of the electrochemical sensor until hydrogen evolution occurs at the surface of one of the wires, thereby forming a hydrogen reference electrode. The voltage of the fuel cell component is then determined with relation to the hydrogen reference electrode.

Kunz, Harold R. (Vernon, CT); Breault, Richard D. (Coventry, CT)

1993-01-01T23:59:59.000Z

439

Colloidal PbS Quantum Dot Solar Cells with High Fill Factor  

E-Print Network [OSTI]

much progress in improving the power conversion efficiency (PCE) of nano- structured solar cells is that the open-circuit voltage (VOC), an important metric that directly affects the PCE, is ex- pected

440

High Energy Density Li-ion Cells for EVs Based on Novel, High...  

Broader source: Energy.gov (indexed) [DOE]

Storage Systems Vehicle Technologies Annual Merit Review 6182014 1 High Energy Density Li-ion Cells for EV's Based on Novel, High Voltage Cathode Material Systems Keith D. Kepler...

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Effect of outer hair cell piezoelectricity on high-frequency receptor potentials  

E-Print Network [OSTI]

The low-pass voltage response of outer hair cells predicted by conventional equivalent circuit analysis, 1996; Ruggero, 1992 . Passive vibration of the basilar membrane and tecto- rial membrane in the cochlea

Popel, Aleksander S.

442

E-Print Network 3.0 - artificial dendritic cells Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Medicine 6 Active Dendrites Reduce Location-Dependent Variability of Synaptic Input Trains Summary: T R O D U C T I O N midal cell, the hypothesis that dendritic voltage-gated...

443

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

SciTech Connect (OSTI)

The purpose of this project was for Seeo to develop a high energy lithium based technology with targets of over 500 Wh/l and 325 Wh/kg. Seeo would leverage the work already achieved with its unique proprietary solid polymer DryLyteTM technology in cells which had a specific energy density of 220 Wh/kg. The development work was focused on establishing a dual electrolyte system, coated cathode particle techniques, various types of additives, and different conductive salts. The program had a duration of three years, with Seeo delivering the final cells at the end of 2014 for evaluation by a DOE laboratory.

Eitouni, Hany; Yang, Jin; Pratt, Russell; Wang, Xiao; Grape, Ulrik

2014-09-29T23:59:59.000Z

444

Intermediate Mirrors to Reach Theoretical Efficiency Limits of Multi-Bandgap Solar Cells  

E-Print Network [OSTI]

Creating a single bandgap solar cell that approaches the Shockley-Queisser limit requires a highly reflective rear mirror. This mirror enhances the voltage of the solar cell by providing photons with multiple opportunities for escaping out the front surface. Efficient external luminescence is a pre-requisite for high voltage. Intermediate mirrors in a multijunction solar cell can enhance the voltage for each cell in the stack. These intermediate mirrors need to have the added function of transmitting the below bandgap photons to the next cell in the stack. In this work, we quantitatively establish the efficiency increase possible with the use of intermediate selective reflectors between cells in a tandem stack. The absolute efficiency increase can be up to ~6% in dual bandgap cells with optimal intermediate and rear mirrors. A practical implementation of an intermediate selective mirror is an air gap sandwiched by antireflection coatings. The air gap provides perfect reflection for angles outside the escape c...

Ganapati, Vidya; Yablonovitch, Eli

2014-01-01T23:59:59.000Z

445

Princeton Power Systems (TRL 5 6 Component)- Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Broader source: Energy.gov [DOE]

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

446

Source of Sustained Voltage Difference between the Xylem of a Potted Ficus benjamina Tree and Its Soil  

E-Print Network [OSTI]

It has long been known that there is a sustained electrical potential (voltage) difference between the xylem of many plants

Mershin, Andreas

447

High-voltage crowbar protection for the large CDF axial drift chamber  

SciTech Connect (OSTI)

The Central Outer Tracker (COT) is a big cylindrical drift chamber that provides charged particle tracking for the Collider Detector at Fermilab experiment. To protect the COT, the large stored energy in the high voltage system needs to be removed quickly when a problem is sensed. For the high voltage switch, a special-order silicon-controlled-rectifier was chosen over more readily available integrated gate bipolar transistors because of layout and reliability questions. The considerations concerning the high voltage switch, the prototype performance, and the experience of more than two years of running are described.

Binkley, M.; Mukherjee, A.; Stuermer, W.; Wagner, R.L.; /Fermilab

2004-01-01T23:59:59.000Z

448

Characteristics of probe current harmonics based on various applied voltage waveforms in low temperature plasmas  

SciTech Connect (OSTI)

The characteristics of probe currents induced by applying various probe voltage waveforms, such as sinusoidal, sawtooth, square, and triangular, were investigated at a floating potential. It was found that the measured probe currents have many harmonics depending on the voltage waveforms. This was mainly due to the nonlinearity of the sheath in the plasma and was analyzed using the fast Fourier transform and a circuit model. By applying a triangular voltage waveform to a probe, plasma parameters such as electron temperature and plasma density could be obtained and compared to those of a single Langmuir probe and a floating harmonic method.

Kim, Young-Do; Kim, Yu-Sin; Lee, Hyo-Chang; Bang, Jin-Young; Chung, Chin-Wook [Department of Electrical Engineering, Hanyang University, 17 Heangdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of)

2011-03-15T23:59:59.000Z

449

High Power, High Voltage FETs in Linear Applications: A User's Perspective  

SciTech Connect (OSTI)

The specifications of the current crop of highpower, high-voltage field-effect transistors (FETs) can lure a designer into employing them in high-voltage DC equipment. Devices with extremely low on-resistance and very high power ratings are available from several manufacturers. However, our experience shows that high-voltage, linear operation of these devices at near-continuous duty can present difficult reliability challenges at stress levels well-below their published specifications. This paper chronicles the design evolution of a 600 volt, 8 ampere shunt regulator for use with megawatt-class radio transmitters, and presents a final design that has met its reliability criteria.

N. Greenough, E. Fredd, S. DePasquale

2009-09-21T23:59:59.000Z

450

EE580 Solar Cells Todd J. Kaiser  

E-Print Network [OSTI]

­ Unleashes electrical energy ­ Unpredictable ­ Destructive · Harnesses electrical energy for human· Harnesses of Electrical Principles · Electric Charge · Electric Current · Electric Fields · Electric Potential Difference University: Solar Cells Lecture 7: EE Fundamentals Electric Potential Difference (Voltage) · Charges

Kaiser, Todd J.

451

High Voltage Electrolytes for Li-ion Batteries  

Broader source: Energy.gov (indexed) [DOE]

0.992 0.994 0.996 0.998 1 0 100 200 300 400 500 600 700 Baseline: 1.2 M LiPF 6 in ECEMC (30:70) Baseline + 5 mM PFBP Baseline + 10 mM AFAC Cycle Number ANL LMNOGR Full Cells...

452

PAPER ACCEPTED TO IEEE TRANSACTIONS ON POWER SYSTEMS, Nov. 2008 1 Reactive Power and Voltage Control in Distribution  

E-Print Network [OSTI]

PAPER ACCEPTED TO IEEE TRANSACTIONS ON POWER SYSTEMS, Nov. 2008 1 Reactive Power and Voltage) problem associated with reactive power and voltage control in distribution systems to minimize daily--Distribution systems, reactive power control, voltage control, optimal switching operations, mixed integer nonlinear

Cañizares, Claudio A.

453

Control of current and voltage oscillations in a short dc discharge making use of external auxiliary electrode  

E-Print Network [OSTI]

Control of current and voltage oscillations in a short dc discharge making use of external://rsi.aip.org/about/rights_and_permissions #12;REVIEW OF SCIENTIFIC INSTRUMENTS 83, 103502 (2012) Control of current and voltage oscillations October 2012) A dc discharge with a hot cathode is subject to current and voltage plasma oscillations

Kaganovich, Igor

454

SP 23.6: A 1.8GHz CMOS Voltage-Controlled Oscillator BehzadRazavi  

E-Print Network [OSTI]

SP 23.6: A 1.8GHz CMOS Voltage-Controlled Oscillator BehzadRazavi University of California, Los that limit the tuning range of monolithic LC voltage-controlled oscillators (VCOs), especially at low supply voltages, and introduces circuit techniques that alle- viate this problem. Incorporating such techniques

Razavi, Behzad

455

>300GHz Fixed-Frequency and Voltage-Controlled Fundamental Oscillators in an InP DHBT Process  

E-Print Network [OSTI]

>300GHz Fixed-Frequency and Voltage-Controlled Fundamental Oscillators in an InP DHBT Process, 93106, USA Abstract -- We report fundamental fixed-frequency and voltage-controlled oscillators bandwidth. Index Terms -- Millimeter-wave oscillators, voltage-controlled oscillators, MMIC oscillators. I

Rodwell, Mark J. W.

456

Effect of Trapping on the Critical Voltage for Degradation in GaN High Electron Mobility Transistors  

E-Print Network [OSTI]

conditions, UV illumination decreases the critical voltage for the onset of degradation in gate current in Ga traps in the fresh state. Keywords­ GaN HEMTs, critical voltage, degradation, UV illuminationEffect of Trapping on the Critical Voltage for Degradation in GaN High Electron Mobility

del Alamo, Jesús A.

457

Offset voltage of Schottky-collector silicon-on-glass vertical PNP's G. Lorito, L. K. Nanver and N. Nenadovi  

E-Print Network [OSTI]

Offset voltage of Schottky-collector silicon-on-glass vertical PNP's G. Lorito, L. K. Nanver and N and investigated with respect to the influence of the collector design on the offset voltage. With Schottky collector contacts the offset voltage can be made both very low (

Technische Universiteit Delft

458

CRADA Final Report: Process development for hybrid solar cells  

SciTech Connect (OSTI)

TCF funding of a CRADA between LBNL and RSLE leveraged RSLE's original $1M investment in LBNL research and led to development of a solar cell fabrication process that will bring the high efficiency, high voltage hybrid tandem solar cell closer to commercialization. RSLE has already built a pilot line at its Phoenix, Arizona site.

Ager, Joel W

2011-02-14T23:59:59.000Z

459

In hippocampal CA1 pyramidal cells and in cerebellar Purkinje cells, transient depolarization by brief trains of  

E-Print Network [OSTI]

In hippocampal CA1 pyramidal cells and in cerebellar Purkinje cells, transient depolarization. This phenomenon, known as depolarization-induced suppression of inhibition (DSI), depends upon Ca2+ influx through voltage-activated Ca2+ channels (Lenz et al. 1998) and appears to involve the production of a retrograde

Zucker, Robert S.

460

Experiment for measurements of the gas breakdown statistics by ramp voltage pulses  

SciTech Connect (OSTI)

In the first part of this article the electronic automatic system for the measurements of dynamic breakdown voltages U{sub b} with linearly rising (ramp) pulses is presented. It generates the sequence of ramp pulses with subvoltage level U{sub sub}{approx_equal}0 during the relaxation time {tau} of the tube, and the ramp pulses start from the static breakdown voltage U{sub s}, thus enabling the correct study of electrical breakdowns and relaxation in gases. In the second part the measurements in argon with and without a voltage during the off period of the pulse are analyzed. The influence of the subvoltage on the mean value of the breakdown voltage U{sub b} as a function of the rise rate k, on the statistical U{sub b} distributions and on the afterglow kinetics is also discussed.

Markovic, V. Lj.; Stamenkovic, S. N.; Gocic, S. R.; Petrovic, Z. Lj. [Department of Physics, University of Nis, P.O. Box 224, 18001 Nis (Serbia and Montenegro); Institute of Physics, P.O. Box 68, 11080 Belgrade (Serbia and Montenegro)

2006-09-15T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Analysis of asset health : an approach to monitoring and diagnostics for medium voltage circuit breakers  

E-Print Network [OSTI]

The Medium Voltage Electric Industry is a very conservative and risk adverse sector that has undergone very little change in the past 30 years when compared to other technologically dependent activities; this reality is ...

Corona, Erick (Erick Gustavo)

2013-01-01T23:59:59.000Z

462

A SCR SWITCHED CAPACITOR VOLTAGE REGULATOR FOR 150 kV NEUTRAL BEAM POWER SUPPLY  

E-Print Network [OSTI]

et a1. , "150-kV, 80-A Solid State Power Supply for Neutral100% solid state and provides 1% regulation at power levelssolid state high voltage re- gulator. The block diagram of the power

Milnes, K.A.

2011-01-01T23:59:59.000Z

463

E-Print Network 3.0 - affects voltage-gated calcium Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

, 1115-1118 3 Dolphin, A.C. (2003) b subunits of voltage-gated calcium channels. J. Bioenerg. Biomembr... . 35, 599-620 4 Van Petegem, F. et al. (2004) Structure of a complex...

464

Voltage, Stability and Diffusion Barrier Differences between Sodium-ion and Lithium-ion Intercalation Materials  

E-Print Network [OSTI]

To evaluate the potential of Na-ion batteries, we contrast in this work the difference between Na-ion and Li-ion based intercalation chemistries in terms of three key battery properties—voltage, phase stability and diffusion ...

Ong, Shyue Ping

465

Spin-torque diode radio-frequency detector with voltage tuned resonance  

SciTech Connect (OSTI)

We report on a voltage-tunable radio-frequency (RF) detector based on a magnetic tunnel junction (MTJ). The spin-torque diode effect is used to excite and/or detect RF oscillations in the magnetic free layer of the MTJ. In order to reduce the overall in-plane magnetic anisotropy of the free layer, we take advantage of the perpendicular magnetic anisotropy at the interface between ferromagnetic and insulating layers. The applied bias voltage is shown to have a significant influence on the magnetic anisotropy, and thus on the resonance frequency of the device. This influence also depends on the voltage polarity. The obtained results are accounted for in terms of the interplay of spin-transfer-torque and voltage-controlled magnetic anisotropy effects.

Skowro?ski, Witold, E-mail: skowron@agh.edu.pl; Frankowski, Marek; Stobiecki, Tomasz [AGH University of Science and Technology, Department of Electronics, Al. Mickiewicza 30, 30-059 Kraków (Poland); Wrona, Jerzy [AGH University of Science and Technology, Department of Electronics, Al. Mickiewicza 30, 30-059 Kraków (Poland); Singulus Technologies, Kahl am Main 63796 (Germany); Ogrodnik, Piotr [Faculty of Physics, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warsaw (Poland); AGH University of Science and Technology, Department of Electronics, Al. Mickiewicza 30, 30-059 Kraków (Poland); Barna?, Józef [Faculty of Physics, Adam Mickiewicz University, ul. Umultowska 85, 61-614 Pozna? (Poland); Institute of Molecular Physics, Polish Academy of Sciences, Smoluchowskiego 17, 60-179 Pozna? (Poland)

2014-08-18T23:59:59.000Z

466

Current mode integrators and their applications in low-voltage high frequency CMOS signal processing  

E-Print Network [OSTI]

Low voltage CMOS fully differential integrators for high frequency continuous-time filters using current-mode techniques are presented.. Current mode techniques are employed to avoid the use of the floating differential pair, in order to achieve...

Smith, Sterling Lane

1993-01-01T23:59:59.000Z

467

Source of stray voltage and effect on cow health and performance  

SciTech Connect (OSTI)

In dairy cows, two distinct and important aspects of the interrelationship between stray voltage problems on the farm and dairy cow productivity can be identified. One is behavioral modification that increases in intensity when currents associated with neutral-to-earth voltages above .7 V find a pathway through the cow. The other is immediate endocrine response. Results of research are less clear on the current necessary for the latter to occur; it may require 8 mA or more. This implies, depending on the pathway and the cow's pathway resistance, that voltage difference between two cow contact points must exceed 3 V. Resistance of different cow pathways range from 350 to 1700 OMEGA. Milk production is more likely to be affected adversely when cows are subjected to shock patterns both intermittent and irregular. This paper identifies various sources of stray voltage problems and discusses appropriate procedures for correction.

Appleman, R.D.; Gustafson, R.J.

1985-01-01T23:59:59.000Z

468

Harmonic control of multiple-stator induction machines for voltage regulation  

E-Print Network [OSTI]

Small, one to a few horsepower, three-phase induction machines with three sets of electrically-isolated, magnetically-coupled stator winding circuits are described. A voltage inverter is developed and used to drive one set ...

Holloway, Jack Wade, 1980-

2004-01-01T23:59:59.000Z

469

Inverter Load Rejection Over-Voltage Testing: SolarCity CRADA...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Inverter Load Rejection Over-Voltage Testing SolarCity CRADA Task 1a Final Report A. Nelson, A. Hoke, and S. Chakraborty National Renewable Energy Laboratory J. Chebahtah, T. Wang,...

470

Coordination of Voltage and Frequency Feedback in Load-Frequency Control Capability of Wind Turbine  

E-Print Network [OSTI]

Coordination of Voltage and Frequency Feedback in Load-Frequency Control Capability of Wind Turbine-Frequency Control (LFC) is gradually shifted to Variable Speed Wind Turbines (VSWTs). In order to equip VSWT

Silva, Filipe Faria Da

471

High-Efficiency Multiple-Output DC-DC Conversion for Low-Voltage Systems  

E-Print Network [OSTI]

This versatile power converter controller provides dual outputs at a fixed switching frequency and can regulate either output voltage or target system delay (using an external -- filter). In the voltage regulation mode, the output voltage is monitored with an analog--digital (A/D) converter, and the feedback compensation network is implemented digitally. The generation of the pulsewidth modulation (PWM) signal is done with a hybrid delay line/counter approach, which saves power and area relative to previous implementations. Power devices are included on chip to create the two independently regulated output PWM signals. The key features of this design are its low-power dissipation, reconfigurability, use of either delay or voltage feedback, and multiple outputs.

Abram P. Dancy; Rajeevan Amirtharajah; Anantha P. Chandrakasan

2000-01-01T23:59:59.000Z

472

Manufacturing challenges of optical current and voltage sensors for utility applications  

SciTech Connect (OSTI)

Measurement of voltages and currents in power transmission and distribution systems are critical to the electric utility industry for both revenue metering and reliability. Nonconventional instrument transformers based on intensity modulation of optical signals have been reported in the literature for more than 20 years. Recently described devices using passive bulk optical sensor elements include the Electro-Optic Voltage Transducer (EOVT) and Magneto-Optic Current Transducer (MOCT). These technologies offer substantial advantages over conventional instrument transformers in accuracy, optical isolation bandwidth, environmental compatibility, weight and size. This paper describes design and manufacturing issues associated with the EOVT and the Optical Metering Unit (OMU) recently introduced by ABB with field installation results presented for prototype units in the 345 kV and 420 kV voltage classes. The OMU incorporates an EOVT and MOCT to monitor the voltage and current on power transmission lines using a single free-standing device.

Yakymyshyn, C.P. [Montana State Univ., Bozeman, MT (United States). Dept. of Electrical and Computer Engineering; Brubaker, M.A. [Los Alamos National Lab., NM (United States); Johnston, P.M. [Johnston (Paul M.), Raleigh, NC (United States); Reinbold, C. [ABB High Voltage Switchgear, Greensburg, PA (United States)

1997-12-01T23:59:59.000Z

473

Analysis of three-phase rectifiers with constant-voltage loads  

E-Print Network [OSTI]

This work presents a quantitative analysis of the operating characteristics of three-phase diode bridge rectifiers with AC-side reactance and constant-voltage loads. We focus on the case where the AC-side currents vary ...

Caliskan, Vahe

474

A multilevel energy buffer and voltage modulator for grid-interfaced micro-inverters  

E-Print Network [OSTI]

Micro-inverters operating into the single-phase grid from solar photovoltaic (PV) panels or other low-voltage sources must buffer the twice-line-frequency variations between the energy sourced by the PV panel and that ...

Chen, Minjie

475

A Multilevel Energy Buffer and Voltage Modulator for Grid-Interfaced Microinverters  

E-Print Network [OSTI]

Microinverters operating into the single-phase grid from solar photovoltaic (PV) panels or other low-voltage sources must buffer the twice-line-frequency variations between the energy sourced by the PV panel and that ...

Chen, Minjie

476

Arc voltage distribution skewness as an indicator of electrode gap during vacuum arc remelting  

DOE Patents [OSTI]

The electrode gap of a VAR is monitored by determining the skewness of a distribution of gap voltage measurements. A decrease in skewness indicates an increase in gap and may be used to control the gap.

Williamson, Rodney L. (Albuquerque, NM); Zanner, Frank J. (Sandia Park, NM); Grose, Stephen M. (Glenwood, WV)

1998-01-01T23:59:59.000Z

477

Arc voltage distribution skewness as an indicator of electrode gap during vacuum arc remelting  

DOE Patents [OSTI]

The electrode gap of a VAR is monitored by determining the skewness of a distribution of gap voltage measurements. A decrease in skewness indicates an increase in gap and may be used to control the gap. 4 figs.

Williamson, R.L.; Zanner, F.J.; Grose, S.M.

1998-01-13T23:59:59.000Z

478

Hybrid integrated active antennas, voltage-controlled oscillators and switchable & tunable CPW-slotline filters  

E-Print Network [OSTI]

HYBRID INTEGRATED ACTIVE ANTENNAS, VOLTAGE-CONTROLLED OSCILLATORS AND SWITCHABLE & TUNABLE CPW-SLOTLINE FILTERS A Thesis by JULIO ANGEL NAVARRO Submitted to the Office of Graduate Studies of Texas ARM University in partial fulfillment... of the requirements for the degree of MASTER OF SCIENCE December 1990 Major Subject: Electrical Engineering HYBRID INTEGRATED ACTIVE ANTENNAS, VOLTAGE-CONTROLLED OSCILLATORS AND SWITCHABLE 2 TUNABLE CPW-SLOTLINE FILTERS A Thesis by JULIO ANGEL NAVARRO...

Navarro, Julio A

1990-01-01T23:59:59.000Z

479

Non-transposed, three phase transmission lines: a study of their effect on load voltages.  

E-Print Network [OSTI]

TRANSMISSION LINES A S'PJDY OF THEIR EFFECT ON LOAD VOLTAGES A Thesis By Robert Dean Chenoweth August 1951 NON-TRANSPOSED~ THREE PHASE TRANSMISSION LINES A STUDY OF THEIR EFFECT ON LOAD VOLTAGES A Thesis Submitted to the Faculty of the Agricultural... all large blocks of alternating current power are transmitted from the generating station to the load by means of three phase transmission lines. With present day equipment this method is economical and when ~ properly designed gives very...

Chenoweth, Robert Dean

1951-01-01T23:59:59.000Z

480

Binary inorganic salt mixtures as high conductivity liquid electrolytes for .100 uC fuel cells{  

E-Print Network [OSTI]

Binary inorganic salt mixtures as high conductivity liquid electrolytes for .100 uC fuel cells cations (e.g. ammonium) as electrolytes in fuel cells operating in the temperature range 100­200 uC, where cell operating with optimized electrodes in the same temperature range, while open circuit voltages

Angell, C. Austen

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

TAS-2013-0043 1 Abstract--Fuel cells are electrochemical energy converters  

E-Print Network [OSTI]

of the perfectly direct current relies upon a fuel cell fed by hydrogen. The main advantages to be taken from fuelTAS-2013-0043 1 Abstract--Fuel cells are electrochemical energy converters which allow generation. Fuel cells are then by essence low voltage sources , so that for most practical applications

Boyer, Edmond

482

The design, construction, and operation of long-distance high-voltage electricity transmission technologies.  

SciTech Connect (OSTI)

This report focuses on transmission lines, which operate at voltages of 115 kV and higher. Currently, the highest voltage lines comprising the North American power grid are at 765 kV. The grid is the network of transmission lines that interconnect most large power plants on the North American continent. One transmission line at this high voltage was built near Chicago as part of the interconnection for three large nuclear power plants southwest of the city. Lines at this voltage also serve markets in New York and New England, also very high demand regions. The large power transfers along the West Coast are generally at 230 or 500 kV. Just as there are practical limits to centralization of power production, there are practical limits to increasing line voltage. As voltage increases, the height of the supporting towers, the size of the insulators, the distance between conductors on a tower, and even the width of the right-of-way (ROW) required increase. These design features safely isolate the electric power, which has an increasing tendency to arc to ground as the voltage (or electrical potential) increases. In addition, very high voltages (345 kV and above) are subject to corona losses. These losses are a result of ionization of the atmosphere, and can amount to several megawatts of wasted power. Furthermore, they are a local nuisance to radio transmission and can produce a noticeable hum. Centralized power production has advantages of economies of scale and special resource availability (for instance, hydro resources), but centralized power requires long-distance transfers of power both to reach customers and to provide interconnections for reliability. Long distances are most economically served at high voltages, which require large-scale equipment and impose a substantial footprint on the corridors through which power passes. The most visible components of the transmission system are the conductors that provide paths for the power and the towers that keep these conductors at a safe distance from each other and from the ground and the natural and built environment. Common elements that are generally less visible (or at least more easily overlooked) include the maintained ROW along the path of the towers, access roads needed for maintenance, and staging areas used for initial construction that may be restored after construction is complete. Also visible but less common elements along the corridor may include switching stations or substations, where lines of similar or different voltages meet to transfer power.

Molburg, J. C.; Kavicky, J. A.; Picel, K. C.

2008-03-03T23:59:59.000Z

483

Three-junction solar cell  

DOE Patents [OSTI]

A photovoltaic solar cell is formed in a monolithic semiconductor. The cell contains three junctions. In sequence from the light-entering face, the junctions have a high, a medium, and a low energy gap. The lower junctions are connected in series by one or more metallic members connecting the top of the lower junction through apertures to the bottom of the middle junction. The upper junction is connected in voltage opposition to the lower and middle junctions by second metallic electrodes deposited in holes 60 through the upper junction. The second electrodes are connected to an external terminal.

Ludowise, Michael J. (Cupertino, CA)

1986-01-01T23:59:59.000Z

484

Piezoelectric Microvalve for Flow Control in Polymer Electrolyte Fuel Cells  

SciTech Connect (OSTI)

Maldistribution of fuel across the cells of a fuel cell stack is an issue that can contribute to poor cell performance and possible cell failure. It has been proposed that an array of microvalves could promote even distribution of fuel across a fuel cell stack. A piezoelectric microvalve has been developed for this purpose. This valve can be tuned to a nominal flow rate (and failure position) from which the actuator would either increase or decrease the flow rate and fuel. The valve can successfully regulate the flow of fuel from 0.7 to 1.1 slpm of hydrogen in the range of temperatures from 80° to 100°C and has been tested over pressure drops from 0.5 to 1 psi. A bank of these valves is currently being tested in a four-cell stack at the U.S. Department of Energy National Energy Technology Laboratory.

Bucci, B.A. (Univ. of Pittsburgh); Vipperman, J.S. (Univ. of Pittsburgh); Clark, W. (Univ. of Pittsburgh); Hensel, J.P.; Thornton, J.D.; Kim. S. (LG Electronics Inc.)

2006-11-01T23:59:59.000Z

485

Layered electrodes for lithium cells and batteries  

DOE Patents [OSTI]

Lithium metal oxide compounds of nominal formula Li.sub.2MO.sub.2, in which M represents two or more positively charged metal ions, selected predominantly and preferably from the first row of transition metals are disclosed herein. The Li.sub.2MO.sub.2 compounds have a layered-type structure, which can be used as positive electrodes for lithium electrochemical cells, or as a precursor for the in-situ electrochemical fabrication of LiMO.sub.2 electrodes. The Li.sub.2MO.sub.2 compounds of the invention may have additional functions in lithium cells, for example, as end-of-discharge indicators, or as negative electrodes for lithium cells.

Johnson, Christopher S. (Naperville, IL); Thackeray, Michael M. (Naperville, IL); Vaughey, John T. (Elmhurst, IL); Kahaian, Arthur J. (Chicago, IL); Kim, Jeom-Soo (Naperville, IL)

2008-04-15T23:59:59.000Z

486

A Transformer-less Partial Power Boost Converter for PV Applications Using a Three-Level Switching Cell  

SciTech Connect (OSTI)

Photovoltaic architectures with distributed power electronics provide many advantages in terms of energy yield as well as system level optimization. As the power level of the solar farm increases it becomes more beneficial to increase the dc collection network voltage, which requires the use of power devices with higher voltage ratings, and thus making the design of efficient, low cost, distributed power converters more challenging. In this paper a simple partial power converter topology is proposed. The topology is implemented using a three-level switching cell, which allows the use of semiconductor devices with lower voltage rating; thus improving design and performance and reducing converter cost. This makes the converters suitable for use for medium to high power applications where dc-link voltages of 600V~1kV may be needed without the need for high voltage devices. Converter operation and experimental results are presented for two partial power circuit variants using three-level switching cells.

Mohammed Agamy; Maja Harfman-Todorovic; Ahmed Elasser; Somasundaram Essakiappan

2013-03-01T23:59:59.000Z

487

Method for forming a cell separator for use in bipolar-stack energy storage devices  

DOE Patents [OSTI]

An improved multi-cell electrochemical energy storage device, such as a battery, fuel cell, or double layer capacitor using a cell separator which allows cells to be stacked and interconnected with low electrical resistance and high reliability while maximizing packaging efficiency. By adding repeating cells, higher voltages can be obtained. The cell separator is formed by applying an organic adhesive on opposing surfaces of adjacent carbon electrodes or surfaces of aerogel electrodes of a pair of adjacent cells prior to or after pyrolysis thereof to form carbon aerogel electrodes. The cell separator is electronically conductive, but ionically isolating, preventing an electrolytic conduction path between adjacent cells in the stack.

Mayer, Steven T. (San Leandro, CA); Feikert, John H. (Livermore, CA); Kaschmitter, James L. (Pleasanton, CA); Pekala, Richard W. (Pleasant Hill, CA)

1994-01-01T23:59:59.000Z

488

Method for forming a cell separator for use in bipolar-stack energy storage devices  

DOE Patents [OSTI]

An improved multi-cell electrochemical energy storage device, such as a battery, fuel cell, or double layer capacitor using a cell separator which allows cells to be stacked and interconnected with low electrical resistance and high reliability while maximizing packaging efficiency. By adding repeating cells, higher voltages can be obtained. The cell separator is formed by applying an organic adhesive on opposing surfaces of adjacent carbon electrodes or surfaces of aerogel electrodes of a pair of adjacent cells prior to or after pyrolysis thereof to form carbon aerogel electrodes. The cell separator is electronically conductive, but ionically isolating, preventing an electrolytic conduction path between adjacent cells in the stack. 2 figs.

Mayer, S.T.; Feikert, J.H.; Kaschmitter, J.L.; Pekala, R.W.

1994-08-09T23:59:59.000Z

489

Cell separator for use in bipolar-stack energy storage devices  

DOE Patents [OSTI]

An improved multi-cell electrochemical energy storage device, such as a battery, fuel cell, or double layer capacitor using a cell separator which allows cells to be stacked and interconnected with low electrical resistance and high reliability while maximizing packaging efficiency. By adding repeating cells, higher voltages can be obtained. The cell separator is formed by applying an organic adhesive on opposing surfaces of adjacent carbon electrodes or surfaces of aerogel electrodes of a pair of adjacent cells prior to or after pyrolysis thereof to form carbon aerogel electrodes. The cell separator is electronically conductive, but ionically isolating, preventing an electrolytic conduction path between adjacent cells in the stack.

Mayer, Steven T. (San Leandro, CA); Feikert, John H. (Livermore, CA); Kachmitter, James L. (Pleasanton, CA); Pekala, Richard W. (Pleasant Hill, CA)

1995-01-01T23:59:59.000Z

490

Using Distributed Energy Resources to Supply Reactive Power for Dynamic Voltage Regulation  

SciTech Connect (OSTI)

Abstract Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a DE source with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction of multiple DE at different locations under different load levels may have an impact to the control parameter setting for each individual DE control system. Future research is needed to find out the interaction of DEs to identify the optimal control parameter settings with the consideration of many factors such as system configuration, load variation, and so on

Xu, Yan [ORNL; Li, Fangxing [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Rizy, D Tom [ORNL; Kueck, John D [ORNL

2008-01-01T23:59:59.000Z

491

An expert system for voltage control in a power system network  

SciTech Connect (OSTI)

This paper presents a prototype of an expert system for alleviation of voltage violations in the day-to-day operation of large power networks. Voltage control for varying load and generation conditions can be achieved by co-ordinated control of switchable shunt VAR compensating (SVC) devices and On load transformer taps (OLTC), while generator excitations are used in dynamic control of voltage profile. This paper deals with the development of an expert system for voltage corrections for base case and contingency conditions using switchable shunt reactive compensation and transformer tap settings. The performance of the expert system is compared with the conventional optimization technique of voltage control and concurrent results have been obtained. The proposed expert system has been tested with simulated conditions of a few practical power systems. Results obtained for a 24 bus EHV Indian power network have been included for illustration purpose. The expert system is found to be suitable for on-line application in Energy Control Center as the solution is obtained very fast.

Bansilal; Thukaram, D.; Parthasarathy, K. [Indian Inst. of Science, Bangalore (India). Dept. of Electrical Engineering

1995-12-31T23:59:59.000Z

492

A combined compensation method for the output voltage of an insulated core transformer power supply  

SciTech Connect (OSTI)

An insulated core transformer (ICT) power supply is an ideal high-voltage generator for irradiation accelerators with energy lower than 3 MeV. However, there is a significant problem that the structure of the segmented cores leads to an increase in the leakage flux and voltage differences between rectifier disks. A high level of consistency in the output of the disks helps to achieve a compact structure by improving the utilization of both the rectifier components and the insulation distances, and consequently increase the output voltage of the power supply. The output voltages of the disks which are far away from the primary coils need to be improved to reduce their inhomogeneity. In this study, by investigating and comparing the existing compensation methods, a new combined compensation method is proposed, which increases the turns on the secondary coils and employs parallel capacitors to improve the consistency of the disks, while covering the entire operating range of the power supply. This method turns out to be both feasible and effective during the development of an ICT power supply. The non-uniformity of the output voltages of the disks is less than 3.5% from no-load to full-load, and the power supply reaches an output specification of 350 kV/60 mA.

Yang, L.; Yang, J., E-mail: jyang@mail.hust.edu.cn; Liu, K. F.; Qin, B.; Chen, D. Z. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China)

2014-06-15T23:59:59.000Z

493

Design, conditioning, and performance of a high voltage, high brightness dc photoelectron gun with variable gap  

SciTech Connect (OSTI)

A new high voltage photoemission gun has been constructed at Cornell University which features a segmented insulator and a movable anode, allowing the cathode-anode gap to be adjusted. In this work, we describe the gun's overall mechanical and high voltage design, the surface preparation of components, as well as the clean construction methods. We present high voltage conditioning data using a 50 mm cathode-anode gap, in which the conditioning voltage exceeds 500 kV, as well as at smaller gaps. Finally, we present simulated emittance results obtained from a genetic optimization scheme using voltage values based on the conditioning data. These results indicate that for charges up to 100 pC, a 30 mm gap at 400 kV has equal or smaller 100% emittance than a 50 mm gap at 450 kV, and also a smaller core emittance, when placed as the source for the Cornell energy recovery linac photoinjector with bunch length constrained to be <3 ps rms. For 100 pC up to 0.5 nC charges, the 50 mm gap has larger core emittance than the 30 mm gap, but conversely smaller 100% emittance.

Maxson, Jared; Bazarov, Ivan; Dunham, Bruce; Dobbins, John; Liu, Xianghong; Smolenski, Karl [Cornell Laboratory for Accelerator-Based Sciences and Education, Cornell University, Ithaca, New York 14853 (United States)

2014-09-15T23:59:59.000Z

494

Fuel cell technology for prototype logistic fuel cell mobile systems  

SciTech Connect (OSTI)

Under the aegis of the Advanced Research Project Agency`s family of programs to develop advanced technology for dual use applications, International Fuel Cells Corporation (IFC) is conducting a 39 month program to develop an innovative system concept for DoD Mobile Electric Power (MEP) applications. The concept is to integrate two technologies, the phosphoric acid fuel cell (PAFC) with an auto-thermal reformer (ATR), into an efficient fuel cell power plant of nominally 100-kilowatt rating which operates on logistic fuels (JP-8). The ATR fuel processor is the key to meeting requirements for MEP (including weight, volume, reliability, maintainability, efficiency, and especially operation on logistic fuels); most of the effort is devoted to ATR development. An integrated demonstration test unit culminates the program and displays the benefits of the fuel cell system, relative to the standard 100-kilowatt MEP diesel engine generator set. A successful test provides the basis for proceeding toward deployment. This paper describes the results of the first twelve months of activity during which specific program aims have remained firm.

Sederquist, R.A.; Garow, J.

1995-08-01T23:59:59.000Z

495

Fiber-optic voltage sensor with cladded fiber and evanescent wave variation detection  

DOE Patents [OSTI]

A fiber optic voltage sensor is described which includes a source of light, a reference fiber for receiving a known percentage of the light and an electrostrictive element having terminals across which is applied, a voltage to be measured. The electrostrictive element is responsive to the applied voltage to assume an altered physical state. A measuring fiber also receives a known percentage of light from the light source and is secured about the electrostrictive element. The measuring fiber is provided with a cladding and exhibits an evanescent wave in the cladding. The measuring fiber has a known length which is altered when the electrostrictive element assumes its altered physical state. A differential sensor is provided which senses the intensity of light in both the reference fiber and the measuring fiber and provides an output indicative of the difference between the intensities. 3 figs.

Wood, C.B.

1992-12-15T23:59:59.000Z

496

Testing of High Voltage Surge Protection Devices for Use in Liquid Argon TPC Detectors  

E-Print Network [OSTI]

In this paper we demonstrate the capability of high voltage varistors and gas discharge tube arrestors for use as surge protection devices in liquid argon time projection chamber detectors. The insulating and clamping behavior of each type of device is characterized in air (room temperature), and liquid argon (90~K), and their robustness under high voltage and high energy surges in cryogenic conditions is verified. The protection of vulnerable components in liquid argon during a 150 kV high voltage discharge is also demonstrated. Each device is tested for argon contamination and light emission effects, and both are constrained to levels where no significant impact upon liquid argon time projection chamber functionality is expected. Both devices investigated are shown to be suitable for HV surge protection applications in cryogenic detectors.

J. Asaadi; J. M. Conrad; S. Gollapinni; B. J. P. Jones; H. Jostlein; J. M. St. John; T. Strauss; S. Wolbers; J. Zennamo

2014-06-23T23:59:59.000Z

497

Optimizing performance per watt on GPUs in High Performance Computing: temperature, frequency and voltage effects  

E-Print Network [OSTI]

The magnitude of the real-time digital signal processing challenge attached to large radio astronomical antenna arrays motivates use of high performance computing (HPC) systems. The need for high power efficiency (performance per watt) at remote observatory sites parallels that in HPC broadly, where efficiency is an emerging critical metric. We investigate how the performance per watt of graphics processing units (GPUs) is affected by temperature, core clock frequency and voltage. Our results highlight how the underlying physical processes that govern transistor operation affect power efficiency. In particular, we show experimentally that GPU power consumption grows non-linearly with both temperature and supply voltage, as predicted by physical transistor models. We show lowering GPU supply voltage and increasing clock frequency while maintaining a low die temperature increases the power efficiency of an NVIDIA K20 GPU by up to 37-48% over default settings when running xGPU, a compute-bound code used in radio...

Price, D C; Barsdell, B R; Babich, R; Greenhill, L J

2014-01-01T23:59:59.000Z

498

Multilevel-Dc-Bus Inverter For Providing Sinusoidal And Pwm Electrical Machine Voltages  

DOE Patents [OSTI]

A circuit for controlling an ac machine comprises a full bridge network of commutation switches which are connected to supply current for a corresponding voltage phase to the stator windings, a plurality of diodes, each in parallel connection to a respective one of the commutation switches, a plurality of dc source connections providing a multi-level dc bus for the full bridge network of commutation switches to produce sinusoidal voltages or PWM signals, and a controller connected for control of said dc source connections and said full bridge network of commutation switches to output substantially sinusoidal voltages to the stator windings. With the invention, the number of semiconductor switches is reduced to m+3 for a multi-level dc bus having m levels. A method of machine control is also disclosed.

Su, Gui-Jia [Knoxville, TN

2005-11-29T23:59:59.000Z

499

Design and validation of a high-voltage levitation circuit for electrostatic accelerometers  

SciTech Connect (OSTI)

A simple high-voltage circuit with a voltage range of 0 to 900 V and an open-loop bandwidth of 11 kHz is realized by using an operational amplifier and a MOSFET combination. The circuit is used for the levitation of a test mass of 71 g, suspended below the top-electrodes with a gap distance of 57 ?m, so that the performance of an electrostatic accelerometer can be tested on the ground. The translation noise of the accelerometer, limited by seismic noise, is about 4 × 10{sup ?8} m/s{sup 2}/Hz{sup 1/2} at 0.1 Hz, while the high-voltage coupling noise is one-order of magnitude lower.

Li, G.; Wu, S. C.; Zhou, Z. B.; Bai, Y. Z.; Hu, M.; Luo, J. [MOE Key Laboratory of Fundamental Physical Quantities Measurements, School of Physics, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China)] [MOE Key Laboratory of Fundamental Physical Quantities Measurements, School of Physics, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China)

2013-12-15T23:59:59.000Z

500

Interconnected High-Voltage Pulsed-Power Converters System Design for H? Ion Sources  

E-Print Network [OSTI]

This paper presents the design and experimental validations of a system of three new high-voltage (HV) pulsedpower converters for the H? sources. The system requires three pulsed voltages (50, 40, and 25 kV to ground) at 2-Hz repetition rate, for 700 ?s of usable flat-top. The solution presents ripplefree output voltages and minimal stored energy to protect the ion source from the consequences of arc events. Experimental results on the final full-scale prototype are presented. In case of short-circuit events, the maximal energy delivered to the source is in the Joule range. HV flat-top stability of 1% is experimentally achieved with a simple Proportional-Integral- Derivative regulation and preliminary tuned H? source (e.g., radio frequency control, gas injection, and so forth). The system is running since more than a year with no power converter failures and damage to the source.

Aguglia, D

2014-01-01T23:59:59.000Z