Powered by Deep Web Technologies
Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Property:Nominal Voltage | Open Energy Information  

Open Energy Info (EERE)

Nominal Voltage Nominal Voltage Jump to: navigation, search Property Name Nominal Voltage Property Type Number This is a property of type Number. Pages using the property "Nominal Voltage" Showing 22 pages using this property. D Distributed Generation Study/10 West 66th Street Corp + 480 + Distributed Generation Study/615 kW Waukesha Packaged System + 480 + Distributed Generation Study/Aisin Seiki G60 at Hooligans Bar and Grille + 240 + Distributed Generation Study/Arrow Linen + 480 + Distributed Generation Study/Dakota Station (Minnegasco) + 0 + Distributed Generation Study/Elgin Community College + 4,160 + Distributed Generation Study/Emerling Farm + 480 + Distributed Generation Study/Floyd Bennett + 480 + Distributed Generation Study/Harbec Plastics + 480 +

2

Device for monitoring cell voltage  

SciTech Connect

A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

Doepke, Matthias (Garbsen, DE); Eisermann, Henning (Edermissen, DE)

2012-08-21T23:59:59.000Z

3

Flexible method for monitoring fuel cell voltage  

DOE Patents (OSTI)

A method for equalizing the measured voltage of each cluster in a fuel cell stack wherein at least one of the clusters has a different number of cells than the identical number of cells in the remaining clusters by creating a pseudo voltage for the different cell numbered cluster. The average cell voltage of the all of the cells in the fuel cell stack is calculated and multiplied by a constant equal to the difference in the number of cells in the identical cell clusters and the number of cells in the different numbered cell cluster. The resultant product is added to the actual voltage measured across the different numbered cell cluster to create a pseudo voltage which is equivalent in cell number to the number of cells in the other identical numbered cell clusters.

Mowery, Kenneth D. (Noblesville, IN); Ripley, Eugene V. (Russiaville, IN)

2002-01-01T23:59:59.000Z

4

Dynamic Simulation of Cell Voltage Resonance Effect in Aluminum ...  

Science Conference Proceedings (OSTI)

Dubal Cell Voltage Drop Initiatives towards Low Energy High Amperage Cells · Dynamic Simulation of Cell Voltage Resonance Effect in Aluminum Electrolysis ...

5

Cell Voltage Noise Reduction Based on Wavelet in Aluminum ...  

Science Conference Proceedings (OSTI)

Presentation Title, Cell Voltage Noise Reduction Based on Wavelet in Aluminum ... cell voltage signals collected in aluminium electrolysis process are with high ...

6

Electronic circuit for measuring series connected electrochemical cell voltages  

DOE Patents (OSTI)

An electronic circuit for measuring voltage signals in an energy storage device is disclosed. The electronic circuit includes a plurality of energy storage cells forming the energy storage device. A voltage divider circuit is connected to at least one of the energy storage cells. A current regulating circuit is provided for regulating the current through the voltage divider circuit. A voltage measurement node is associated with the voltage divider circuit for producing a voltage signal which is proportional to the voltage across the energy storage cell.

Ashtiani, Cyrus N. (West Bloomfield, MI); Stuart, Thomas A. (Toledo, OH)

2000-01-01T23:59:59.000Z

7

Nominal rewriting  

Science Conference Proceedings (OSTI)

Nominal rewriting is based on the observation that if we add support for @a-equivalence to first-order syntax using the nominal-set approach, then systems with binding, including higher-order reduction schemes such as @l-calculus beta-reduction, can ... Keywords: ?-Conversion, Binders, Confluence, First and higher-order rewriting

Maribel Fernández; Murdoch J. Gabbay

2007-06-01T23:59:59.000Z

8

Dubal Cell Voltage Drop Initiatives towards Low Energy High ...  

Science Conference Proceedings (OSTI)

About this Abstract. Meeting, 2014 TMS Annual Meeting & Exhibition. Symposium , Aluminum Reduction Technology. Presentation Title, DUBAL CELL VOLTAGE ...

9

Design & Fabrication of a High-Voltage Photovoltaic Cell  

DOE Green Energy (OSTI)

Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

Felder, Jennifer; /North Carolina State U. /SLAC

2012-09-05T23:59:59.000Z

10

Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells  

DOE Patents (OSTI)

Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl{sub 2} and SO{sub 2}Cl{sub 2} electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl{sub 2} and Li/SO{sub 2}Cl{sub 2} batteries.

Delnick, F.M.

1991-04-05T23:59:59.000Z

11

Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells  

DOE Patents (OSTI)

Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl.sub.2 and SO.sub.2 Cl.sub.2 electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl.sub.2 and Li/SO.sub.2 Cl.sub.2 batteries.

Delnick, Frank M. (Albuquerque, NM)

1993-01-01T23:59:59.000Z

12

Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells  

DOE Patents (OSTI)

Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl[sub 2] and SO[sub 2]Cl[sub 2] electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl[sub 2] and Li/SO[sub 2]Cl[sub 2] batteries.

Delnick, F.M.

1993-04-13T23:59:59.000Z

13

Fuel Cell Technology Status - Voltage Degradation (Presentation)  

DOE Green Energy (OSTI)

This presentation describes an independent assessment of fuel cell durability status and discusses the project's relevance to the Department of Energy Hydrogen and Fuel Cells Program; NREL's analysis approach; the FY12 technical accomplishments including the fourth annual publication of results; and project collaborations and future work.

Kurtz, J.; Wipke,; Sprik, S.; Saur, G.

2012-06-01T23:59:59.000Z

14

Methods for improving solar cell open circuit voltage  

DOE Patents (OSTI)

A method for producing a solar cell having an increased open circuit voltage. A layer of cadmium sulfide (CdS) produced by a chemical spray technique and having residual chlorides is exposed to a flow of hydrogen sulfide (H.sub.2 S) heated to a temperature of 400.degree.-600.degree. C. The residual chlorides are reduced and any remaining CdCl.sub.2 is converted to CdS. A heterojunction is formed over the CdS and electrodes are formed. Application of chromium as the positive electrode results in a further increase in the open circuit voltage available from the H.sub.2 S-treated solar cell.

Jordan, John F. (El Paso, TX); Singh, Vijay P. (El Paso, TX)

1979-01-01T23:59:59.000Z

15

Analysis of Solar Cell Quality Using Voltage Metrics: Preprint  

DOE Green Energy (OSTI)

The highest efficiency solar cells provide both excellent voltage and current. Of these, the open-circuit voltage (Voc) is more frequently viewed as an indicator of the material quality. However, since the Voc also depends on the band gap of the material, the difference between the band gap and the Voc is a better metric for comparing material quality of unlike materials. To take this one step further, since Voc also depends on the shape of the absorption edge, we propose to use the ultimate metric: the difference between the measured Voc and the Voc calculated from the external quantum efficiency using a detailed balance approach. This metric is less sensitive to changes in cell design and definition of band gap. The paper defines how to implement this metric and demonstrates how it can be useful in tracking improvements in Voc, especially as Voc approaches its theoretical maximum.

Toberer, E. S.; Tamboli, A. C.; Steiner, M.; Kurtz, S.

2012-06-01T23:59:59.000Z

16

Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal  

E-Print Network (OSTI)

is too low to be used directly for many practical applications. For example, a single light emitting diode (LED) requires a minimum voltage of 2 V.2 Thus, effective methods of boosting MFC voltages

17

2013 Call for Nominations  

NLE Websites -- All DOE Office Websites (Extended Search)

2013 - Nominations are open for the 2013 NERSC Award for Innovative Use of High Performance Computing and the 2013 NERSC Award for High Impact Scientific Achievement. These are...

18

Nomination Form DEPARTMENT / UNIT  

E-Print Network (OSTI)

Nomination Form DEPARTMENT / UNIT: CAMPUS ADDRESS: JOB TITLE: DEPARTMENT EMAIL ADDRESS: DEPARTMENT TELEPHONE: 2014 FRANKLIN STAFF EXCELLENCE AWARDS START DATE IN DEPARTMENT / UNIT: Nominee Information NAME / RESEARCHPROFESSIONAL Signature of Head / Director of Nominee's Unit: NOMINATION PACKET DEADLINE: MARCH 7, 2014 PLEASE

Arnold, Jonathan

19

Nomination Form DEPARTMENT / UNIT  

E-Print Network (OSTI)

Nomination Form DEPARTMENT / UNIT: CAMPUS ADDRESS: JOB TITLE: DEPARTMENT EMAIL ADDRESS: DEPARTMENT TELEPHONE: 2012 FRANKLIN STAFF EXCELLENCE AWARDS START DATE IN DEPARTMENT / UNIT: Nominee Information NAME / RESEARCHPROFESSIONAL Signature of Head / Director of Nominee's Unit: NOMINATION PACKET DEADLINE: FRIDAY MARCH 2, 2012

Arnold, Jonathan

20

Nomination Form DEPARTMENT / UNIT  

E-Print Network (OSTI)

Nomination Form DEPARTMENT / UNIT: CAMPUS ADDRESS: JOB TITLE: DEPARTMENT EMAIL ADDRESS: DEPARTMENT TELEPHONE: 2011 FRANKLIN STAFF EXCELLENCE AWARDS START DATE IN DEPARTMENT / UNIT: Nominee Information NAME / RESEARCHPROFESSIONAL Signature of Head / Director of Nominee's Unit: NOMINATION PACKET DEADLINE: FRIDAY MARCH 4, 2011

Arnold, Jonathan

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Nomination Form DEPARTMENT / UNIT  

E-Print Network (OSTI)

Nomination Form DEPARTMENT / UNIT: CAMPUS ADDRESS: JOB TITLE: DEPARTMENT EMAIL ADDRESS: DEPARTMENT TELEPHONE: 2013 FRANKLIN STAFF EXCELLENCE AWARDS START DATE IN DEPARTMENT / UNIT: Nominee Information NAME / RESEARCHPROFESSIONAL Signature of Head / Director of Nominee's Unit: NOMINATION PACKET DEADLINE: MARCH 5, 2013 PLEASE

Arnold, Jonathan

22

Nomination Form DEPARTMENT / UNIT  

E-Print Network (OSTI)

Nomination Form DEPARTMENT / UNIT: CAMPUS ADDRESS: CLASSIFICATION / TITLE: DEPARTMENT EMAIL ADDRESS: DEPARTMENT TELEPHONE: 2011 FRANKLIN STAFF SERVICE AWARDS START DATE IN DEPARTMENT / UNIT: ACTUAL NUMBER MEMBER DEADLINE: FRIDAY MARCH 4, 2011 ADDITIONAL COMMENTS: Signature of Head / Director of Nominee's Unit

Arnold, Jonathan

23

Nomination Form DEPARTMENT / UNIT  

E-Print Network (OSTI)

Nomination Form DEPARTMENT / UNIT: CAMPUS ADDRESS: CLASSIFICATION / TITLE: DEPARTMENT EMAIL ADDRESS: DEPARTMENT TELEPHONE: 2013 FRANKLIN STAFF SERVICE AWARDS START DATE IN DEPARTMENT / UNIT: ACTUAL NUMBER MEMBER DEADLINE: MARCH 5, 2013 ADDITIONAL COMMENTS: Signature of Head / Director of Nominee's Unit

Arnold, Jonathan

24

Nomination Form DEPARTMENT / UNIT  

E-Print Network (OSTI)

Nomination Form DEPARTMENT / UNIT: CAMPUS ADDRESS: CLASSIFICATION / TITLE: DEPARTMENT EMAIL ADDRESS: DEPARTMENT TELEPHONE: 2012 FRANKLIN STAFF SERVICE AWARDS START DATE IN DEPARTMENT / UNIT: ACTUAL NUMBER MEMBER DEADLINE: FRIDAY MARCH 2, 2012 ADDITIONAL COMMENTS: Signature of Head / Director of Nominee's Unit

Arnold, Jonathan

25

Nomination Form DEPARTMENT / UNIT  

E-Print Network (OSTI)

Nomination Form DEPARTMENT / UNIT: CAMPUS ADDRESS: CLASSIFICATION / TITLE: DEPARTMENT EMAIL ADDRESS: DEPARTMENT TELEPHONE: 2014 FRANKLIN STAFF SERVICE AWARDS START DATE IN DEPARTMENT / UNIT: ACTUAL NUMBER MEMBER DEADLINE: MARCH 7, 2014 ADDITIONAL COMMENTS: Signature of Head / Director of Nominee's Unit

Arnold, Jonathan

26

Secretarial Award Nomination Form  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Secretary's Awards Program Nomination Form Secretary's Awards Program Nomination Form 1. Type of Award (Check Applicable Box) Secretary's Honor Awards Secretary's Departure Awards Secretary's James R. Schlesinger Award Exceptional Service Award Appreciation Award Excellence Award Distinguished Service Award Achievement Award Meritorious Service Award 2. Nominee (Full) Name Check if Group list is attached (As it is to appear on the certificate) For Departure and Appreciation Awards Only 3. Certificate Date 4. Award Presentation Date 5. Current Position Title 6. Award Justification: Continue on blank sheet of paper and attach if you need more space. 7. Award Citation: A citation of no more than 20 lines must be attached to nomination form. 8 . Requesting Office : 9a. Local Approvals: One or more signatures is typical but not required

27

State-of-the-Art Fuel Cell Voltage Durability Status: Spring 2013 Composite Data Products  

DOE Green Energy (OSTI)

This presentation from the U.S. Department of Energy's National Renewable Energy Laboratory includes composite data products (CDPs) produced in 2013 for state-of-the-art fuel cell voltage durability status.

Kurtz, J.; Sprik, S.; Saur, G.; Peters, M.; Post, M.; Ainscough, C.

2013-05-01T23:59:59.000Z

28

Nomination Letter for Gale Warshawsky  

Science Conference Proceedings (OSTI)

February 12, 1996. I nominate Gale Warshawsky of Lawrence Livermore National Laboratories (LLNL) for the FISSEA Educator of the Year. ...

29

Performance of Dynamic Voltage Restorer (DVR) against Voltage Sags and Swells Using Space Vector PWM Technique  

Science Conference Proceedings (OSTI)

Due to increasing complexity in the power system, voltage sags are now becoming one of the most significant power quality problems. Voltage sag is a short reduction voltage from nominal voltage, occurs in a short time. Short-lived voltage sags may not ... Keywords: Custom power, power quality, voltage sag, SPWM, SVPWM, DVR, PSCAD/EMTDC.

Palaparthi Ananthababu; Burle Trinadha; K. Ram Charan

2009-12-01T23:59:59.000Z

30

Differential voltage analyses of high-power lithium-ion cells 4. Cells containing NMC.  

DOE Green Energy (OSTI)

Cells with and without a LiC{sub 2}O{sub 4}BF{sub 2} electrolyte additive and that contained Li{sub 1.05}(Mn{sub 1/3}Co{sub 1/3}Ni{sub 1/3}){sub 0.95}O{sub 2} (NMC) positive electrodes were tested for calendar and cycle life at 60% state of charge. The temperatures used in these tests were 25 and 45 C (cycle life) and 45 and 55 C (calendar life). An analysis of the C/25 capacity data shows that the C/25 capacity decreases with the square root of time. The additive slowed down the rate of capacity decline. The C/25 data were subjected to differential voltage analysis to determine the possible cause of the capacity decrease and at which electrode the capacity decrease was occurring. Data from full cells and half-cells were compared to elucidate individual electrode contributions. This analysis indicated that lithium-capacity-consuming side reactions were occurring primarily at the negative electrode.

Bloom, I.; Walker, L. K.; Basco, J. K.; Abraham, D. P.; Christophersen, J. P.; Ho, C. D.; Chemical Sciences and Engineering Division; INL

2010-02-01T23:59:59.000Z

31

Automatic voltage imbalance detector  

DOE Patents (OSTI)

A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

1984-01-01T23:59:59.000Z

32

Effect of voltage dynamics on response properties in a model of sensory hair cell  

E-Print Network (OSTI)

Sensory hair cells in auditory and vestibular organs rely on active mechanisms to achieve high sensitivity and frequency selectivity. Recent experimental studies have documented self-sustained oscillations in hair cells of lower vertebrates on two distinct levels. First, the hair bundle can undergo spontaneous mechanical oscillations. Second, somatic electric voltage oscillations across the baso-lateral membrane of the hair cell have been observed. We develop a biophysical model of the bullfrog's saccular hair cell consisting of two compartments, mechanical and electrical, to study how the mechanical and the voltage oscillations interact to produce coherent self-sustained oscillations and how this interaction contributes to the overall sensitivity and selectivity of the hair cell. The model incorporates nonlinear mechanical stochastic hair bundle system coupled bi-directionally to a Hodgkin-Huxley type system describing somatic ionic currents. We isolate regions of coherent spontaneous oscillations in the parameter space of the model and then study how coupling between compartments affect sensitivity of the hair cell to external mechanical perturbations. We show that spontaneous electrical oscillations may enhance significantly the sensitivity and selectivity of the hair cell.

Rami Amro; Alexander B. Neiman

2012-09-27T23:59:59.000Z

33

A Novel Dynamic Voltage Restorer with Outage Handling Capability Using Fuzzy Logic Controler  

Science Conference Proceedings (OSTI)

This paper presents a novel dynamic voltage restorer (DVR) capable of handling deep sags including outage on a low voltage distribution system. The DVR recovers sags up to 10% of nominal voltage; otherwise, it will operate as an uninterruptible power ...

M. Ashari; T. Hiyama; M. Pujiantara; H. Suryoatmojo; M. Hery Purnomo

2007-09-01T23:59:59.000Z

34

National Defense University (NDU) Nomination Package Checklist  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

- November 2012 - November 2012 National Defense University (NDU) Nomination Package Checklist SEND 2 COPIES OF THE NOMINATION PACKAGE TO THE NDU UNIVERSITY REGISTRAR'S OFFICE Each student nomination package must include the following items: NDU Student Nomination Form One official transcript (highest degree earned) One-page student biography or résumé (include education and career history) Two Letters of Recommendation World-Wide Travel Statement Statement of Purpose (No more than two pages) Signed National Defense University Privacy Act Statement Signed Education Release Form (if nominating agency requires copies of final student evaluation and/or transcript) SAC students must also include: Senior Acquisition Course Nomination Form

35

Full abstraction for nominal Scott domains  

Science Conference Proceedings (OSTI)

We develop a domain theory within nominal sets and present programming language constructs and results that can be gained from this approach. The development is based on the concept of orbit-finite subset, that is, a subset of a nominal sets that is ... Keywords: denotational semantics, domain theory, full abstraction, nominal sets, symmetry

Steffen Lösch; Andrew M. Pitts

2013-01-01T23:59:59.000Z

36

Automatic voltage-imbalance detector  

DOE Patents (OSTI)

A device is described for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, R.E.; McCormick, J.B.; Kerwin, W.J.

1981-05-20T23:59:59.000Z

37

A nominally second-order accurate finite volume cell-centered scheme for anisotropic diffusion on two-dimensional unstructured grids  

Science Conference Proceedings (OSTI)

In this paper, we describe a second-order accurate cell-centered finite volume method for solving anisotropic diffusion on two-dimensional unstructured grids. The resulting numerical scheme, named CCLAD (Cell-Centered LAgrangian Diffusion), is characterized ... Keywords: Anisotropic diffusion, Cell-centered scheme, Cylindrical geometry, Isotropic diffusion, Second-order accurate finite volume method, Two-dimensional unstructured grid

Pierre-Henri Maire; Jérôme Breil

2012-03-01T23:59:59.000Z

38

Nominations Open for 2013 NERSC HPC Achievement Awards  

NLE Websites -- All DOE Office Websites (Extended Search)

Nominations Open for 2013 NERSC HPC Achievement Awards Nominations Open for 2013 NERSC HPC Achievement Awards January 1, 2013 by Richard Gerber (0 Comments) Nominations are open...

39

An efficient CMOS rectifier with low-voltage operation for RFID tags  

Science Conference Proceedings (OSTI)

A high-efficiency CMOS rectifier for radio-frequency identification (RFID) applications is presented. Using an on-chip generated clock signal, a new switching scheme is proposed to enhance the power efficiency of the conventional 4 transistor (4T)-cell ... Keywords: frequency 950 MHz, efficient CMOS rectifier, low-voltage operation, RFID tags, radio-frequency identification applications, on-chip generated clock signal, power efficiency, conventional 4 transistor-cell rectifier, charge-transfer transistors, small leakage current, external gate-boosting technique, nominal standard threshold voltage, MOS transistors, CMOS technology, power conversion efficiency

P. Kamalinejad; S. Mirabbasi; V. C. M. Leung

2011-07-01T23:59:59.000Z

40

2014 Call for HPC Achievement Award Nominations  

NLE Websites -- All DOE Office Websites (Extended Search)

Award Nominations are open for the 2014 NERSC Award for Innovative Use of High Performance Computing and the 2014 NERSC Award for High Impact Scientific Achievement. NERSC...

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Correlations of Capacitance-Voltage Hysteresis with Thin-Film CdTe Solar Cell Performance During Accelerated Lifetime Testing  

SciTech Connect

In this paper we present the correlation of CdTe solar cell performance with capacitance-voltage hysteresis, defined presently as the difference in capacitance measured at zero-volt bias when collecting such data with different pre-measurement bias conditions. These correlations were obtained on CdTe cells stressed under conditions of 1-sun illumination, open-circuit bias, and an acceleration temperature of approximately 100 degrees C.

Albin, D.; del Cueto, J.

2011-03-01T23:59:59.000Z

42

High power impulse magnetron sputtering: Current-voltage-time ...  

pauses between pulses !typically 20 ms". The nominal volt-age of the pulser was adjustable up to 1000 V. The arc threshold was set to 120 A. If the current exceeded this

43

Motor voltage asymmetry influence to the efficient energy usage  

Science Conference Proceedings (OSTI)

Analysis of the effect of unbalanced voltages on the three-phase induction motor is presented in the paper. Since the unbalanced voltage of 2%, 3.5% and 5% increase in losses could reach, in the same order, the amount of 8%, 25% and 50% of nominal power ... Keywords: asymetry, energy efficiency, induction motor, power losses, standard

Miloje Kostic; Aleksandar Nikolic

2010-07-01T23:59:59.000Z

44

A Bidirectional, Triple-Voltage DC-DC Converter for Hybrid and Fuel Cell Vehicle Power Systems  

Science Conference Proceedings (OSTI)

Electrical power systems in future hybrid and fuel cell vehicles may employ three voltage (14V, 42V and high voltage (HV)) nets. These will be necessary to accommodate existing 14V loads as well as efficiently handle new heavy loads at the 42V net and an electrical traction drive on the HV bus. A low-cost bi-directional dc-dc converter was proposed in (10) for connecting the three voltage nets. The converter consists of two half-bridges and a high-frequency transformer; thus minimizing the number of switching devices and their associated gate driver components. One salient feature is that the half-bridge on the 42V bus is also utilized to provide the 14V bus by operating its duty ratio around an atypical value of 1/3. This eliminates the need for an additional 14V/42V converter. Moreover, it makes use of the parasitic capacitance of the switches and the transformer leakage inductance for soft-switching; no extra active switches or passive resonant components are required. The use of half-bridges makes the topology suitable for interleaved multi-phase configurations as a means to increase the power level because the capacitor legs can be shared. This paper presents simulation and experimental results on an interleaved two-phase arrangement rated at 4.5 kW. Also discussed are the benefits of operating with the atypical duty ratio on the transformer and a preferred multi-phase configuration to minimize capacitor ripple currents.

Su, Gui-Jia [ORNL; Tang, Lixin [ORNL

2007-01-01T23:59:59.000Z

45

Aviation Management Professional Award Nomination for:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Professional Nomination for Professional Nomination for Managerial/Official Award: Joseph M. Ginanni Aviation Manager US Department of Energy/National Nuclear Security Administration, Nevada Site Office Bio Joseph M. Ginanni Aviation Manager National Nuclear Security Administration Nevada Site Office Mr. Ginanni has worked for the Nevada Site Office (NSO) since 1991. For the past five years, he has served as the NSO Aviation Manager, managing and overseeing the Management and Operating contractor's aviation services department and their operation and maintenance of NSO's five aircraft (3 Beechcraft King Airs and 2 Bell 412s) which are stationed at both Nellis AFB, NV and Andrews AFB, MD. Prior to his position as Aviation Manager, he was the team leader for the Radioactive Waste

46

Polymer solar cells with enhanced open-circuit voltage and efficiency  

E-Print Network (OSTI)

was then added to the solutions and stirred before use. The solutions were spin-coated on indium tin oxide (ITO.77%, as certified by the National Renewable Energy Laboratory. Polymer solar cells (PSCs) have attracted much measured PCE being 7.73%. Devices were then encapsulated and sent to the National Renewable Energy

Ismagilov, Rustem F.

47

Low circumferential voltage gradient self supporting electrode for solid oxide fuel cells  

DOE Patents (OSTI)

The porous, self-supporting, elongated electrode is made, having at least two chambers through its axial length, the chambers separated by an electronically conductive member. This electrode can be an air electrode of a fuel cell, having a superimposed solid electrolyte and fuel electrode.

Reichner, Philip (Plum Boro, PA)

1989-01-01T23:59:59.000Z

48

Price of Cameron, LA Natural Gas LNG Imports (Nominal Dollars...  

U.S. Energy Information Administration (EIA) Indexed Site

(Nominal Dollars per Thousand Cubic Feet) Price of Cameron, LA Natural Gas LNG Imports (Nominal Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5...

49

FinalTestimonyLaneNominationStatement.pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

JEFF LANE, NOMINEE TO BE AN ASSISTANT JEFF LANE, NOMINEE TO BE AN ASSISTANT SECRETARY OF ENERGY, CONGRESSIONAL AND INTERGOVERNMENTAL AFFAIRS, DEPARTMENT OF ENERGY MARCH 17, 2010 Chairman Bingaman, Ranking Member Murkowski, and distinguished Members of the Committee, it is an honor and a privilege to appear before you today as President Obama's nominee for Assistant Secretary of Energy for Congressional and Intergovernmental Affairs. I want to thank Secretary Chu for recommending me to the President and thank the Committee for holding this hearing. As you consider my nomination for this position, I hope you will take into account my record, my experiences and my commitment of service to the Congress and to the important mission of the Department of Energy. I have spent most of my professional life - almost 16 years - serving in senior staff positions in

50

Specifying a Low-Voltage Dynamic Sag Corrector  

Science Conference Proceedings (OSTI)

Voltage sags are the most frequent and costly of power quality problems for industrial customers. A number of non-battery-based technologies have emerged in the market to mitigate the effects of voltage sags on industrial processes. Among these, the low-voltage dynamic sag corrector (DySC) can provide ride-through during sags to 50 percent of nominal voltage for up to 12 cycles with no energy storage; for longer ride-through or deeper sags, energy storage capacitors are available as an option. This repor...

2000-11-07T23:59:59.000Z

51

Lowering Power using the Voltage Identification Bit  

E-Print Network (OSTI)

Voltage identification is a form of adaptive voltage scaling (AVS). The voltage-identification technique described in this application note enables certain devices in the Virtex®-7 family to be operated at a lower voltage of 0.9V while delivering the same specified performance as that of a device operating at the nominal supply voltage of 1.0V. Voltage identification capable devices consume approximately 30 % lower worst case (maximum) static power and correspondingly dissipate less heat. Reduced power consumption is a desirable characteristic and one that Xilinx 7 series FPGAs fulfill in multiple ways. The primary purpose of the voltage-identification technique is to reduce the worst-case power consumption of-1C devices. However, the significance of the voltage-identification technique goes beyond an individual device dissipating less energy, it also can lower the overall system cost. Power supplies and thermal management requirements are normally specified based on the worst-case power demands of all the system’s components. Although the 7 series FPGAs-1C devices are the most cost-effective, the total cost of a product is the sum of all parts, and costs associated with the power supply and thermal management can be significant. The voltage-identification technique specifically reduces worst-case power consumption, which reduces the overall costs associated with specifying a larger power supply, requiring a heat sink, adding forced air cooling, or including similar devices. This application note shows the technical aspects of implementing the voltage-identification technique and introduces a reference design for the VC707 evaluation kit. It also explains how voltage identification fits into the complete power portfolio of Virtex-7 FPGAs and highlights the benefits of using the voltage-identification technique to reduce power consumption and system costs.

Ken Chapman; Jameel Hussein

2012-01-01T23:59:59.000Z

52

Unlikely Combination of Experiments With a Novel High-Voltage CIGS Photovoltaic Array: Preprint  

DOE Green Energy (OSTI)

A new high-voltage array comprising bipolar strings of copper indium gallium diselenide (CIGS) photovoltaic (PV) modules was inaugurated in 2005. It is equipped with a unique combination of tests, which likely have never before been deployed simultaneously within a single array: full current-voltage (I-V) traces, high-voltage leakage current measurements, and peak-power tracking or temporal stepped-bias profiling. The array nominally produces 1 kW power at 1 sun. The array's electrical characteristics are continuously monitored and controlled with a programmable electronic load interfaced to a data acquisition system (DAS), that also records solar and meteorological data. The modules are mounted with their frames electrically isolated from earth ground, in order to facilitate measurement of the leakage currents that arise between the high voltage bias developed in the series-connected cells and modules and their mounting frames. Because the DAS can perform stepped biasing of the array as a function of time, synchronous detection of the leakage current data with alternating bias is available. Leakage current data and their dependence on temperature and voltage are investigated. Array power data are analyzed across a wide range of varying illuminations and temperatures from the I-V traces. Array performance is also analyzed from an energy output perspective using peak-power tracking data.

del Cueto, J. A.; Sekulic, B. R.

2006-05-01T23:59:59.000Z

53

DOE General Counsel Nomination Announcement | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

General Counsel Nomination Announcement General Counsel Nomination Announcement DOE General Counsel Nomination Announcement March 18, 2009 - 12:00am Addthis WASHINGTON, DC - Today, President Barack Obama announced his intent to nominate the following individuals to key administration posts: Susan Burk, Special Representative of the President, with the rank of Ambassador, State Department; Raphael Bostic, Assistant Secretary for Policy Development and Research, Department of Housing and Urban Development; Michelle J. DePass, Assistant Administrator for International Affairs, Environmental Protection Agency; Cynthia J. Giles, Assistant Administrator for Enforcement and Compliance Assurance, Environmental Protection Agency; Michael L. Connor, Director, Bureau of Reclamation, Department of the Interior; Scott Blake

54

Optimization Online - Validation of Nominations in Gas Network ...  

E-Print Network (OSTI)

Nov 30, 2012... the validation of nomination problem: Given a gas transmission network consisting of passive pipelines and active, controllable elements and ...

55

A Review Of Water Contents Of Nominally Anhydrous Natural Minerals...  

Open Energy Info (EERE)

A Review Of Water Contents Of Nominally Anhydrous Natural Minerals In The Mantles Of Earth, Mars And The Moon Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal...

56

NETL: News Release - DOE Opens Nomination Process for 2002 Homer...  

NLE Websites -- All DOE Office Websites (Extended Search)

Nomination Process For 2002 Homer Lowry Award Award Honors Outstanding Achievement By Fossil Fuels Scientist or Engineer WASHINGTON, DC - Homer H. Lowry Award The U.S....

57

Follicle-stimulating hormone receptor-mediated uptake of sup 45 Ca sup 2+ by proteoliposomes and cultured rat sertoli cells: Evidence for involvement of voltage-activated and voltage-independent calcium channels  

Science Conference Proceedings (OSTI)

We have previously reported incorporation into liposomes of Triton X-100-solubilized FSH receptor-G-protein complexes derived from purified bovine calf testis membranes. In the present study we have used this model system to show that FSH induces flux of 45Ca2+ into such proteoliposomes in a hormone-specific concentration-dependent manner. FSH, inactivated by boiling, had no stimulatory effect on 45Ca2+ flux, nor did isolated alpha- or beta-subunits of FSH. Addition of GTP (or its analogs 5'-guanylylimidodiphosphate and guanosine-5'-O-(3-thiotriphosphate)) or sodium fluoride (in the presence or absence of GTP or its analogs) failed to induce 45Ca2+ flux into proteoliposomes, suggesting that the uptake of 45Ca2+ was receptor, and not G-protein, related. Voltage-independent (ruthenium red and gadolinium chloride) and voltage-activated (methyoxyverapamil and nifedipine) calcium channel-blocking agents reduced FSH-stimulated 45Ca2+ flux into proteoliposomes to control levels. FSH also induced uptake of 45Ca2+ by cultured rat Sertoli cells. Ruthenium red and gadolinium chloride had no effect on basal levels of 45Ca2+ uptake or estradiol secretion by cultured rat Sertoli cells, nor did methoxyverapamil or nifedipine. All four calcium channel blockers, however, were able to reduce FSH-induced 45Ca2+ uptake to basal levels and FSH-stimulated conversion of androstenedione to estradiol by up to 50%, indicating an involvement of Ca2+ in FSH-stimulated steroidogenesis. Our results suggest that the well documented changes in intracellular calcium levels consequent to FSH binding may be due, at least in part, to an influx of calcium through FSH receptor-regulated calcium channels.

Grasso, P.; Reichert, L.E. Jr. (Albany Medical College, NY (USA))

1989-12-01T23:59:59.000Z

58

Enhancing Open Circuit Voltage by Combining Thermoelectric ...  

Science Conference Proceedings (OSTI)

Enhancing Open Circuit Voltage by Combining Thermoelectric Materials and Dye -Sensitized Solar Cell in Series · Estimation of Compressive Strength of High ...

59

PQ Encyclopedia: Understanding Voltage Unbalance  

Science Conference Proceedings (OSTI)

This PQ Encyclopedia examines voltage unbalance, methods to calculate line voltages and the degree of voltage unbalance, and mitigation techniques.

2009-12-11T23:59:59.000Z

60

A Multiattribute Utility Analysis of Sites Nominated For Characterization  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

A Multiattribute Utility Analysis of Sites Nominated For A Multiattribute Utility Analysis of Sites Nominated For Characterization For the First Radioactive Waste Repository - A Decision Aiding Methodology A Multiattribute Utility Analysis of Sites Nominated For Characterization For the First Radioactive Waste Repository - A Decision Aiding Methodology Summary In December 1984, the Department of Energy (DOE) published draft environmental assessments (EAs) to support the proposed nomination of five sites and the recommendation of three sites for characterization for the first radioactive-waste repository. A chapter common to all the draft EAs (Chapter 7) presented rankings of the five sites against the postclosure and the preclosure technical siting guidelines. To determine which three sites appeared most favorable for recommendation for characterization,

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

DOE Under Secretary Nomination Announcement | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Under Secretary Nomination Announcement Under Secretary Nomination Announcement DOE Under Secretary Nomination Announcement March 12, 2009 - 12:00am Addthis WASHINGTON, DC - Today, President Barack Obama announced his intent to nominate the following individuals to key administration posts: Demetrios Marantis, Nominee for Deputy United States Trade Representative; Kristina M. Johnson, Nominee for Under Secretary of Energy; Gina McCarthy, Nominee for Assistant Administrator for Air and Radiation, Environmental Protection Agency; and Ronald H. Weich, Nominee for Assistant Attorney General, Office of Legislative Affairs, Department of Justice. President Obama said, "Each of these individuals brings a unique talent and dedication to the causes we are tackling everyday in my administration. Together they bring decades of public service and diverse backgrounds that

62

Agency Energy Coordinators for Award Nominations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Agency Energy Coordinators for Award Nominations Agency Energy Coordinators for Award Nominations Agency Energy Coordinators for Award Nominations October 7, 2013 - 4:41pm Addthis Federal agency energy coordinators handle all nominations for the Federal Energy and Water Management Awards. Contact your agency energy coordinator well in advance of all award deadlines to learn about internal submission processes. Don Juhasz Defense Logistics Agency 703-767-3537 Jerard Butler General Services Administration 202-401-0855 Mark Ewing General Services Administration 202-708-9296 Wayne Thalasinos National Aeronautics and Space Administration 202-358-3811 Mark Sprouse National Archives and Records Administration 301-837-3019 David Hauk Smithsonian Institution 202-633-1537 Leslie Ford Social Security Administration 410-594-0111

63

Nominate An Inspirational STEM Teacher for the Nation's Highest Honors |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nominate An Inspirational STEM Teacher for the Nation's Highest Nominate An Inspirational STEM Teacher for the Nation's Highest Honors Nominate An Inspirational STEM Teacher for the Nation's Highest Honors February 8, 2013 - 1:04pm Addthis President Barack Obama talks with Presidential Awards for Excellence in Mathematics and Science Teaching winners in the State Dining of the White House January 6, 2010. (Official White House Photo by Chuck Kennedy) President Barack Obama talks with Presidential Awards for Excellence in Mathematics and Science Teaching winners in the State Dining of the White House January 6, 2010. (Official White House Photo by Chuck Kennedy) How can I participate? The 2013 Awards will honor mathematics and science (including computer science) teachers working in grades 7-12. Nominations close on

64

EERE News: President Obama Nominates New Energy Department and...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

New Energy Department and EPA Heads President Obama on March 4 nominated Ernest Moniz to replace Steven Chu as Secretary of Energy, and Gina McCarthy to take over U.S....

65

Do parties still matter? : the politics of gubernatorial nominations  

E-Print Network (OSTI)

Who controls the nomination in gubernatorial elections? This dissertation seeks to answer this simple question. Parties have classically been the organizations held responsible for throwing their collective effort behind ...

Cobb, Rachael V

2006-01-01T23:59:59.000Z

66

Analysis of Hippocampal Cell Proliferation, Survival, and Neuronal Morphology in P/Q-Type Voltage-Gated Calcium Channel Mutant Mice  

E-Print Network (OSTI)

Tottering and leaner mutant mice carry mutations in the pore-forming subunit (?1A) of P/Q-type (CaV 2.1) voltage-gated calcium ion (Ca2+) channels that result in reduced Ca2+ current density. Since Ca2+ influx via voltage-dependent Ca2+ channels regulates important Ca2+-dependent neuronal processes including neurotransmitter release and synaptogenesis, we assessed effects of these mutations on hippocampus volume, neuronal density, neuronal morphology of hippocampal pyramidal cells in adult (six-month-old) mice, and adult neurogenesis in three-week-old and six-month-old mice. Hippocampal volume and neuronal density were assessed using hematoxylin and eosin stained serial sections. Neuronal morphology was assessed using Golgi-Cox staining as well as ultrastructural assessment using transmission electron microscopy. Adult hippocampal neurogenesis was assessed using standard 5-bromo-2’-deoxyuridine (BrdU) labeling with fluorescent immunohistochemistry (IHC) and proliferating cell nuclear antigen (PCNA) with diaminobenzidine IHC. To determine neuron and astrocyte survival, we used fluorescent double labeling for neurons with BrdU-neuronal nuclei IHC or astrocytes using BrdU-glial fibrillary acidic protein, respectively. Fluoro-Jade histochemistry was used to assess numbers of degenerating cells in the dentate gyrus subgranular zone. Decreased hippocampus volume was observed in tottering female mice and increased dentate hilar and CA1 cell density in mutant mice compared to wild type mice. Cell proliferation was increased in the hilus and combined CA3, CA2 and CA1 regions of mutant mice compared to wild type mice. Decreased total dendritic length and decreased number of dendritic intersections was observed in tottering mice compared to wild type mice. The decrease in dendritic arborization of tottering mice occurred at the concentric circles close to the neuronal cell body indicating that basal dendrites of CA1 pyramidal neurons are reduced. Taken together, P/Q-type voltage gated calcium channel mutation has age variable influence on adult hippocampal cell proliferation, and it altered neuronal morphology in terms of dendritic complexity in tottering mice, while the leaner mutation reduced mitochondrial density.

Nigussie, Fikru

2013-05-01T23:59:59.000Z

67

Theoretical Analysis of Effects of Deep Level, Back Contact, and Absorber Thickness on Capacitance-Voltage Profiling of CdTe Thin-Film Solar Cells  

Science Conference Proceedings (OSTI)

The apparent carrier density profile measured by the capacitance-voltage technique in CdTe thin-film solar cells frequently displays a distinctive U-shape. We show that, even assuming a uniform carrier density, such a U-shape may arise from deep levels, a non-ohmic back-contact, and a thin absorber, which are commonly present in practical CdTe thin-film solar cells. A thin CdTe absorber contributes to the right branch of the U-shape due to a punch-through effect at reverse or zero biases, when the CdTe absorber is nearly fully depleted. A rectifying back-contact contributes to both branches of the U-shape due to voltage sharing with the front junction under a forward bias and early punch-through under a reverse bias. Deep levels contribute to the right branch, but also raise the bottom of the U-shape, leading to an overestimate of carrier density.

Li, J. V.; Halverson, A. F.; Sulima, O. V.; Bansal, S.; Burst, J. M.; Barnes, T. M.; Gessert, T. A.; Levi, D. H.

2012-05-01T23:59:59.000Z

68

HIGH VOLTAGE GENERATOR  

DOE Patents (OSTI)

This patent relates to high voltage supply circuits adapted for providing operating voltages for GeigerMueller counter tubes, and is especially directed to an arrangement for maintaining uniform voltage under changing conditions of operation. In the usual power supply arrangement for counter tubes the counter voltage is taken from across the power supply output capacitor. If the count rate exceeds the current delivering capaciiy of the capacitor, the capacitor voltage will drop, decreasing the counter voltage. The present invention provides a multivibrator which has its output voltage controlled by a signal proportional to the counting rate. As the counting rate increases beyond the current delivering capacity of the capacitor, the rectified voltage output from the multivibrator is increased to maintain uniform counter voltage.

Zito, G.V.

1959-04-21T23:59:59.000Z

69

Mitigation of different type voltage sags in low voltage distribution systems using dynamic voltage restorer  

Science Conference Proceedings (OSTI)

The main problems of the voltage sag in low voltage distribution systems due to sensitive loads. Voltage sags can caused malfunction in the distribution system. In order to protect voltage sags in the network a device which called Dynamic Voltage Restorer ... Keywords: custom device, dynamic voltage restorer (DVR), low voltage, power injected, voltage sag

Rosli Omar

2010-03-01T23:59:59.000Z

70

4-28-09_Final_Testimony_(Triay)_(Nomination).pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8, 2009 8, 2009 Good morning, Mr. Chairman, Senator McCain, members of the Committee. It is a great honor to appear before you today as President Obama's nominee to be the Assistant Secretary for Environmental Management at the United States Department of Energy. I thank Secretary Chu and President Obama for their support and confidence in recommending and nominating me. I also thank the Committee for considering my nomination. I would like to introduce my husband of 24 years, Dr. John Hall, and his parents Mr. and Mrs. Harvey Hall, who are with me here today. In 1961, when my parents fled Cuba's Communist regime and went into exile with a three- year-old daughter and nothing but their dreams for a better life and their love for freedom, it would have been impossible to believe that their daughter would ever be nominated by the

71

The Effect of Operational Voltage on a Solid Oxide Fuel Cell Operating on Coal Syngas Containing Trace Amounts of Phosphine.  

E-Print Network (OSTI)

??Electrolyte-supported Solid Oxide Fuel Cells have been proven capable of generating usable electricity when supplied with various fuels, including a synthetic fuel (syngas) generated from… (more)

Kaufman, Brian A.

2011-01-01T23:59:59.000Z

72

DOE Encourages Utility Sector Nominations to the Federal Communications  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

the Federal the Federal Communications Commission's Communications, Security, Reliability, and Interoperability Council DOE Encourages Utility Sector Nominations to the Federal Communications Commission's Communications, Security, Reliability, and Interoperability Council March 29, 2011 - 5:22pm Addthis Because of the role communications technologies will play in the evolution toward a smarter national grid, DOE recommended in its October 2010 report, The Communications Requirements of Smart Grid Technologies, that members of the utility sector become more engaged in the federal advisory committees that consider key policy issues related to the Smart Grid, including the reliability of communications networks. Last week, the Federal Communications Commission announced that it is seeking nominations

73

Constant voltage ultracapacitor  

Science Conference Proceedings (OSTI)

Ultracapacitors have attracted lots of attention recently due to their growing use in hybrid vehicles and in energy storage applications for the smart grid. A very undesirable feature of ultracapacitors is the fact that the voltage drops as the capacitor is discharged. DC-DC converters are employed at present to convert the voltage of the ultracapacitor to constant voltage; however

Ezzat G. Bakhoum

2012-01-01T23:59:59.000Z

74

A novel approach for the improvement of open circuit voltage and fill factor of InGaAsSb/GaSb thermophotovoltaic cells  

DOE Green Energy (OSTI)

Heterojunction n-Al{sub 0.25}Ga{sub 0.75}As{sub 0.02}Sb{sub 098}/p-In{sub 0.16}Ga{sub 0.84}As{sub 0.04}Sb{sub 0.96} thermophotovoltaic (TPV) cells were grown by molecular-beam epitaxy on n-GaSb-substrates. In the spectral range from 1 {micro}m to 2.1 {micro}m these cells, as well as homojunction n-p-In{sub 0.16}Ga{sub 0.84}As{sub 0.04}Sb{sub 0.96} cells, have demonstrated internal quantum efficiencies exceeding 80%, despite about a 200 meV barrier in the conduction band at the heterointerface. Estimation shows that the thermal emission of the electrons photogenerated in p-region over this barrier can provide high efficiency for hetero-cells if the electron recombination time in p-In{sub 0.16}Ga{sub 0.84}As{sub 0.04}Sb{sub 0.96}is longer than 10 ns. Keeping the same internal efficiency as homojunction cells, hetero-cells provide a unique opportunity to decrease the dark forward current and thereby increase open circuit voltage (V{sub {proportional_to}}) and fill factor at a given illumination level. It is shown that the decrease of the forward current in hetero-cells is due to the lower recombination rate in n-type wider-bandgap space-charge region and to the suppression of the hole component of the forward current. The improvement in V{sub {proportional_to}} reaches 100% at illumination level equivalent to 1 mA/cm{sup 2} and it decreases to 5% at the highest illumination levels (2--3 A/cm{sup 2}), where the electron current component dominates in both the homo- and heterojunction cells. Values of V{sub {proportional_to}} as high as 310 meV have been obtained for a hetero-cell at illumination levels of 3 A/cm{sup 2}. Under this condition, the expected fill factor value is about 72% for a hetero-cell with improved series resistance. The heterojunction concept provides excellent prospects for further reduction of the dark forward current in TPV cells.

Garbuzov, D.Z.; Martinelli, R.U.; Khalfin, V.; Lee, H.; Morris, N.A.; Taylor, G.C.; Connolly, J.C. [Sarnoff Corp., Princeton, NJ (United States); Charache, G.W.; DePoy, D.M. [Lockheed-Martin, Inc., Schenectady, NY (United States)

1997-10-01T23:59:59.000Z

75

Nominal Position Controller for Permanent Magnet Synchronous Motor System  

Science Conference Proceedings (OSTI)

A nonlinear position controller for permanent magnet synchronous motor (PMSM) was designed to achieve position tracing control and robust control. The controller included two parts: the model controller and the robust controller. The former was designed ... Keywords: PMSM, nominal control, sliding mode control

Yuzeng Zhang; Fan Wang; Mingyin Yan

2010-05-01T23:59:59.000Z

76

Distribution of Local Open-Circuit Voltage on Amorphous and Nanocrystalline Mixed-Phase Si:H and SiGe:H Solar Cells: Preprint  

DOE Green Energy (OSTI)

Local open-circuit voltage (Voc) distributions on amorphous and nanocrystalline mixed-phase silicon solar cells were measured using a scanning Kelvin probe microscope (SKPM) on the p layer of an n-i-p structure without the top ITO contact. During the measurement, the sample was illuminated with a laser beam that was used for the atomic force microscopy (AFM). Therefore, the surface potential measured by SKPM is the sum of the local Voc and the difference in workfunction between the p layer and the AFM tip. Comparing the SKPM and AFM images, we find that nanocrystallites aggregate in the amorphous matrix with an aggregation size of {approx}0.5 ..mu..m in diameter, where many nanometer-size grains are clustered. The Voc distribution shows valleys in the nanocrystalline aggregation area. The transition from low to high Voc regions is a gradual change within a distance of about 1 ..mu..m. The minimum Voc value in the nanocrystalline clusters in the mixed-phase region is larger than the Voc of a nc-Si:H single-phase solar cell. These results could be due to lateral photo-charge redistribution between the two phases. We have also carried out local Voc measurements on mixed-phase SiGe:H alloy solar cells. The magnitudes of Voc in the amorphous and nanocrystalline regions are consistent with the J-V measurements.

Jiang, C.-S.; Moutinho, H. R.; Al-Jassim, M. M.; Kazmerski, L. L.; Yan, B.; Owens, J. M.; Yang, J.; Guha, S.

2006-05-01T23:59:59.000Z

77

Why is the open-circuit voltage of crystalline Si solar cells so critically dependent on emitter- and base-doping?  

DOE Green Energy (OSTI)

This paper discusses the critical dependence of the open-circuit voltage (VOC) of crystalline Si solar cells on the emitter and base doping levels. Contrary to conventional models that try to ascribe VOC-limitations to (independent) bulk and surface recombination losses, the authors suggest, as the dominant mechanism, the formation of a compensated ``buffer layer'' that is formed as phosphorus is diffused into the p-type (boron-doped) base. The only purpose of the base doping is to optimize the buffer layer. Their calculations show that this model makes the achievement of high VOC and good carrier collection (JSC, FF) interdependent. Sanyo's ``HIT'' solar cells are an example of a different method to implement this buffer layer concept for crystalline Si solar cells. The general principle for a VOC-enhancing buffer layer relies on using materials with high lifetimes and low carrier mobilities that are capable of reducing surface or junction recombination by reducing the flow of carriers into this loss-pathway.

Von Roedern, B.; Bauer, G.H.

1999-10-26T23:59:59.000Z

78

High voltage photovoltaic power converter  

DOE Patents (OSTI)

An array of independently connected photovoltaic cells on a semi-insulating substrate contains reflective coatings between the cells to enhance efficiency. A uniform, flat top laser beam profile is illuminated upon the array to produce electrical current having high voltage. An essentially wireless system includes a laser energy source being fed through optic fiber and cast upon the photovoltaic cell array to prevent stray electrical signals prior to use of the current from the array. Direct bandgap, single crystal semiconductor materials, such as GaAs, are commonly used in the array. Useful applications of the system include locations where high voltages are provided to confined spaces such as in explosive detonation, accelerators, photo cathodes and medical appliances.

Haigh, Ronald E. (Arvada, CO); Wojtczuk, Steve (Cambridge, MA); Jacobson, Gerard F. (Livermore, CA); Hagans, Karla G. (Livermore, CA)

2001-01-01T23:59:59.000Z

79

NREL: Measurements and Characterization - Current Versus Voltage  

NLE Websites -- All DOE Office Websites (Extended Search)

Current Versus Voltage Current Versus Voltage The National Renewable Energy Laboratory (NREL) Device Performance group uses current versus voltage (I-V) measurement systems to assess the main performance parameters for photovoltaic (PV) cells and modules. I-V measurement systems determine the output performance of devices, including: open-circuit voltage (Voc), short-circuit current (Isc), fill factor (FF), maximum power output of the device (Pmax), voltage at maximum power (Vmax), current at maximum power (Imax), and conversion efficiency of the device (η). Some I-V systems may also be used to perform dark I-V measurements to determine diode properties and series and shunt resistances. We use three I-V systems to measure performance of individual PV cells; and four for modules - two for measurements under simulated conditions; and

80

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.

Rankin, R.; Kotter, D.

1992-12-31T23:59:59.000Z

82

4-23-09_Final_Nomination_Testimony_(Triay).pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3, 2009 3, 2009 Good afternoon, Mr. Chairman, Senator Murkowski, members of the Committee. It is a great honor to appear before you today as President Obama's nominee to be the Assistant Secretary for Environmental Management at the United States Department of Energy. I thank Secretary Chu and President Obama for their support and confidence in recommending and nominating me. I also thank the Committee for considering my nomination. I would like to introduce my husband of 24 years, Dr. John Hall, and his parents Mr. and Mrs. Harvey Hall, who are with me here today. In 1961, when my parents fled Cuba's Communist regime and went into exile with a three- year-old daughter and nothing but their dreams for a better life and their love for freedom, it

83

4-23-09_Final_Nomination_Testimony_(Koonin).pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Steven E. Koonin Steven E. Koonin Under Secretary for Science Designee Senate Committee on Energy and Natural Resources April 23, 2009 Chairman Bingaman, Senator Murkowski, members of the Committee, I am honored to appear before you as President Obama's nominee for Under Secretary for Science in the Department of Energy. With me this afternoon are my wife Laurie, who has been my companion and support for 39 years, and the second of our three children, Alyson, a junior at the University of Richmond. As you consider my nomination, I thought it would be useful for me to say something about myself beyond the bare biographical facts, something about my perceptions of Science in the Department of Energy, and about what I hope to accomplish if my nomination is confirmed.

84

A FAILURE ACCOMMODATING BATTERY MANAGEMENT SYSTEM WITH INDIVIDUAL CELL EQUALIZERS AND STATE OF CHARGE OBSERVERS.  

E-Print Network (OSTI)

??Lithium-ion batteries are the most commonly chosen power source for many portable applications. Advantages like high energy density, high nominal voltage, less maintenance, and low… (more)

Annavajjula, Vamsi Krishna

2007-01-01T23:59:59.000Z

85

Automated Voltage Standard Ready  

Science Conference Proceedings (OSTI)

... “We wanted a standard that was ... as envisioned, then within our lifetimes there will no longer be a need for voltage transfer standards that have to be ...

2013-04-08T23:59:59.000Z

86

Common Information Model Meter Outage Nominal Interoperability Test Procedure  

Science Conference Proceedings (OSTI)

The CIM Meter Outage Nominal Interoperability Test Procedure is one in a series of EPRI CIM Interoperability Test Procedures (ETIPs) created by EPRI whose purpose is to thoroughly document the actors, interfaces, and test steps for the interoperability testing of specific parts of the International Electrotechnical Commission (IEC) Common Information Model (CIM) standard. The Test Procedures are initially being used for EPRI demonstration tests and are intended, over time, to form the basis of a set of C...

2011-12-16T23:59:59.000Z

87

High Voltage Safety Act | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High Voltage Safety Act High Voltage Safety Act High Voltage Safety Act < Back Eligibility Commercial Construction Developer General Public/Consumer Industrial Installer/Contractor Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Safety and Operational Guidelines Siting and Permitting The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage electric lines by providing that no work shall be done in the vicinity of such lines unless and until the owner or operator thereof has been notified of such work and has taken the appropriate safety measures. The Georgia Public Service Commission requires

88

Price of Gulf of Mexico Natural Gas LNG Imports (Nominal Dollars...  

Annual Energy Outlook 2012 (EIA)

(Nominal Dollars per Thousand Cubic Feet) Price of Gulf of Mexico Natural Gas LNG Imports (Nominal Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3 Year-4...

89

Price of Cameron, LA Natural Gas LNG Imports from Qatar (Nominal...  

Gasoline and Diesel Fuel Update (EIA)

from Qatar (Nominal Dollars per Thousand Cubic Feet) Price of Cameron, LA Natural Gas LNG Imports from Qatar (Nominal Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2...

90

Price of Everett, MA Natural Gas LNG Imports from Egypt (Nominal...  

Annual Energy Outlook 2012 (EIA)

Egypt (Nominal Dollars per Thousand Cubic Feet) Price of Everett, MA Natural Gas LNG Imports from Egypt (Nominal Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3...

91

Price of Cove Point, MD Natural Gas LNG Imports from Egypt (Nominal...  

U.S. Energy Information Administration (EIA) Indexed Site

Egypt (Nominal Dollars per Thousand Cubic Feet) Price of Cove Point, MD Natural Gas LNG Imports from Egypt (Nominal Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2...

92

Voltage Quality Improvement Using DVR  

Science Conference Proceedings (OSTI)

The problem of voltage sags and Swells and its severe impact on sensitive loads is well known. To solve this problem, custom power devices are used. One of those devices is the Dynamic Voltage Restorer (DVR), which is one of the most efficient and effective ... Keywords: Dynamic Voltage Restorer (DVR), Voltage sags, Voltage swells, Custom power, Power Quality

M. Arun Bhaskar; S. S. Dash; C. Subramani; M. Jagadeesh Kumar; P. R. Giresh; M. Varun Kumar

2010-03-01T23:59:59.000Z

93

Voltage balanced multilevel voltage source converter system  

SciTech Connect

A voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

94

Voltage balanced multilevel voltage source converter system  

SciTech Connect

Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-07-01T23:59:59.000Z

95

Substation voltage upgrading  

SciTech Connect

Substation voltage uprating, i.e., conversion of a substation from a lower rated voltage to a higher rated voltage without a complete substation rebuild, can lead to excellent economic benefits. Utilization of the old substation layout and/or the existing equipment, to some extent, is the practical objective of such an uprating. The objective of this project was to assess the opportunities for substation uprating in the industry, to establish feasibility for such uprating and to study methods for accomplishing it. The final aim of the project was to provide guidance to utilities interested in uprating. 56 refs., 41 figs., 18 tabs.

Panek, J.; Elahi, H.; Sublich, M. (General Electric Co., Schenectady, NY (USA). Systems Development and Engineering Dept.)

1989-08-01T23:59:59.000Z

96

Current-Voltage and Capacitance-Voltage characteristics of Pd ...  

Science Conference Proceedings (OSTI)

Presentation Title, Current-Voltage and Capacitance-Voltage characteristics of Pd ... Nonlocal Modeling in High Rate Deformation and Ductile Fracture of ...

97

Analysis of Laboratory Fuel Cell Technology Status Â… Voltage Degradation - DOE Hydrogen and Fuel Cells Program FY 2012 Annual Progress Report  

NLE Websites -- All DOE Office Websites (Extended Search)

FY 2012 Annual Progress Report DOE Hydrogen and Fuel Cells Program Jennifer Kurtz (Primary Contact), Keith Wipke, Sam Sprik, Genevieve Saur, Huyen Dinh National Renewable Energy Laboratory (NREL) 15013 Denver West Parkway Golden, CO 80401-3305 Phone: (303) 275-4061 Email: jennifer.kurtz@nrel.gov DOE Manager HQ: Kathi Epping Martin Phone: (202) 586-7425 Email: Kathi.Epping@ee.dog.gov Project Start Date: July 1, 2009 Project End Date: Project continuation and direction determined annually by DOE Fiscal Year (FY) 2012 Objectives Conduct an independent assessment to benchmark * state-of-the-art fuel cell durability in a non-proprietary method Leverage analysis experience from the Fuel Cell Electric * Vehicle Learning Demonstration project Collaborate with key fuel cell developers on the analysis

98

High voltage DC power supply  

DOE Patents (OSTI)

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

Droege, T.F.

1989-12-19T23:59:59.000Z

99

? Adjustable Output Voltage  

E-Print Network (OSTI)

The LM25010 features all the functions needed to implement a low cost, efficient, buck regulator capable of supplying in excess of 1A load current. This high voltage regulator integrates an N-Channel Buck Switch, and is available in thermally enhanced LLP-10 and TSSOP-14EP packages. The constant on-time regulation scheme requires no loop compensation resulting in fast load transient response and simplified circuit implementation. The operating frequency remains constant with line and load variations due to the inverse relationship between the input voltage and the on-time. The valley current limit detection is set at 1.25A. Additional features include: VCC under-voltage lock-out, thermal shutdown, gate drive under-voltage lock-out, and maximum duty cycle limiter.

Lmq Is Aec-q Grade

2008-01-01T23:59:59.000Z

100

Low-voltage gyrotrons  

SciTech Connect

For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5-10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%-2% in the submillimeter wavelength region).

Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S. [Institute of Applied Physics RAS, N. Novgorod 603600 (Russian Federation); Nusinovich, G. S. [IREAP, University of Maryland, College Park, Maryland 20742-3511 (United States)

2013-03-15T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Comparative High Voltage Impulse Measurement  

Science Conference Proceedings (OSTI)

... substrate and surrounded by insulating oil; the low ... the amplitudes of the voltage peaks that are ... The uncertainties in the peak output voltages for the ...

2013-04-19T23:59:59.000Z

102

Nomination & Selection Guidelines | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Nomination & Selection Guidelines Nomination & Selection Guidelines The Ernest Orlando Lawrence Award Lawrence Award Home Nomination & Selection Guidelines Award Laureates Ceremony The Life of Ernest Orlando Lawrence Contact Information The Ernest Orlando Lawrence Award U.S. Department of Energy SC-2/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-9395 E: lawrence.award@science.doe.gov Nomination & Selection Guidelines Print Text Size: A A A RSS Feeds FeedbackShare Page Jump to: Nomination Guidelines | Lawrence Award Category Descriptions | Lawrence Award Assessment Criteria, Merit Review, and Selection | Preparation of Nomination Materials | Additional Information The 2013 Ernest Orlando Lawrence Award Nomination Guidelines The Ernest Orlando Lawrence Award is bestowed by the Secretary of the U.S.

103

5_5_09_Daniel_Poneman_Nomination.pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Daniel B. Poneman Daniel B. Poneman Before the Committee on Energy and Natural Resources United States Senate May 5, 2009 Chairman Bingaman, Ranking Member Murkowski, and distinguished Members of the Committee, it is an honor and a privilege to appear before you today as President Obama's nominee to be Deputy Secretary of Energy. I would like to introduce my wife of nearly 25 years, Susan, and our sons, Michael and William. Our daughter, Claire, is away at college. I am grateful and humbled by the confidence that President Obama and Secretary Chu have expressed in me through this nomination. President Obama has articulated a clear and compelling vision of America's energy future - one that will transform our economy, protect our security, and save our planet from the worst impacts of climate change.

104

Electron launching voltage monitor  

DOE Patents (OSTI)

An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors.

Mendel, Clifford W. (Albuquerque, NM); Savage, Mark E. (Albuquerque, NM)

1992-01-01T23:59:59.000Z

105

Voltage controlled current source  

DOE Patents (OSTI)

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, Gregory M. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

106

High frequency breakdown voltage  

SciTech Connect

This report contains information about the effect of frequency on the breakdown voltage of an air gap at standard pressure and temperature, 76 mm Hg and O{degrees}C, respectively. The frequencies of interest are 47 MHz and 60 MHz. Additionally, the breakdown in vacuum is briefly considered. The breakdown mechanism is explained on the basis of collision and ionization. The presence of the positive ions produced by ionization enhances the field in the gap, and thus determines the breakdown. When a low-frequency voltage is applied across the gap, the breakdown mechanism is the same as that caused by the DC or static voltage. However, when the frequency exceeds the first critical value f{sub c}, the positive ions are trapped in the gap, increasing the field considerably. This makes the breakdown occur earlier; in other words, the breakdown voltage is lowered. As the frequency increases two decades or more, the second critical frequency, f{sub ce}, is reached. This time the electrons start being trapped in the gap. Those electrons that travel multiple times across the gap before reaching the positive electrode result in an enormous number of electrons and positive ions being present in the gap. The result is a further decrease of the breakdown voltage. However, increasing the frequency does not decrease the breakdown voltage correspondingly. In fact, the associated breakdown field intensity is almost constant (about 29 kV/cm).The reason is that the recombination rate increases and counterbalances the production rate, thus reducing the effect of the positive ions` concentration in the gap. The theory of collision and ionization does not apply to the breakdown in vacuum. It seems that the breakdown in vacuum is primarily determined by the irregularities on the surfaces of the electrodes. Therefore, the effect of frequency on the breakdown, if any, is of secondary importance.

Chu, Thanh Duy

1992-03-01T23:59:59.000Z

107

Nomination & Selection Guidelines | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Nomination & Selection Guidelines Nomination & Selection Guidelines The Enrico Fermi Award Fermi Award Home Nomination & Selection Guidelines Award Laureates Ceremony The Life of Enrico Fermi Contact Information The Enrico Fermi Award U.S. Department of Energy SC-2/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-9395 E: fermi.award@science.doe.gov Nomination & Selection Guidelines Print Text Size: A A A RSS Feeds FeedbackShare Page Jump to: Fermi Award Assessment Criteria, Merit Review, and Selection | Preparation of Nomination Materials The 2013 Enrico Fermi Award Nomination Guidelines The Enrico Fermi Award is bestowed by the President of the United States to an individual or individuals of international stature in recognition of exceptional scientific, technical, engineering, and/or management

108

High voltage pulse conditioning  

DOE Patents (OSTI)

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Stringfield, R.M.; Wheat, R.M. Jr.

1989-02-21T23:59:59.000Z

109

High voltage pulse conditioning  

DOE Patents (OSTI)

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

1990-01-01T23:59:59.000Z

110

HIGH VOLTAGE GENERATOR  

DOE Patents (OSTI)

A generator is presented for producing relatively large currents at high voltages. In general, the invention comprises a plurality of capacitors connected in series by a plurality of switches alternately disposed with the capacitors. The circuit is mounted for movement with respect to contact members and switch closure means so that a load device and power supply are connected across successive numbers of capacitors, while the other capacitors are successively charged with the same power supply.

Schwemin, A.J.

1959-03-17T23:59:59.000Z

111

HIGH VOLTAGE GENERATOR  

DOE Patents (OSTI)

A generator for producing relatively large currents at high voltages is described. In general, the invention comprises a plurality of capacitors connected in series by a plurality of switches alternately disposed with the capacitors. The above-noted circuit is mounted for movement with respect to contact members and switch closure means so that a load device and power supply are connected across successive numbers of capacitors, while the other capacitors are successively charged with the same power supply.

Schwemin, A.J.

1959-03-17T23:59:59.000Z

112

HIGH VOLTAGE ION SOURCE  

DOE Patents (OSTI)

A device is described for providing a source of molecular ions having a large output current and with an accelerated energy of the order of 600 kv. Ions are produced in an ion source which is provided with a water-cooled source grid of metal to effect maximum recombination of atomic ions to molecular ions. A very high accelerating voltage is applied to withdraw and accelerate the molecular ions from the source, and means are provided for dumping the excess electrons at the lowest possible potentials. An accelerating grid is placed adjacent to the source grid and a slotted, grounded accelerating electrode is placed adjacent to the accelerating grid. A potential of about 35 kv is maintained between the source grid and accelerating grid, and a potential of about 600 kv is maintained between the accelerating grid and accelerating electrode. In order to keep at a minimum the large number of oscillating electrons which are created when such high voltages are employed in the vicinity of a strong magnetic field, a plurality of high voltage cascaded shields are employed with a conventional electron dumping system being employed between each shield so as to dump the electrons at the lowest possible potential rather than at 600 kv.

Luce, J.S.

1960-04-19T23:59:59.000Z

113

High voltage variable diameter insulator  

DOE Patents (OSTI)

A high voltage feedthrough assembly (10) having a tubular insulator (15) extending between the ground plane ring (16) and the high voltage ring (30). The insulator (15) is made of Pyrex and decreases in diameter from the ground plane ring (16) to the high voltage ring (30), producing equipotential lines almost perpendicular to the wall (27) of the insulator (15) to optimize the voltage-holding capability of the feedthrough assembly (10).

Vanecek, David L. (Martinez, CA); Pike, Chester D. (Pinole, CA)

1984-01-01T23:59:59.000Z

114

Intelligent robust control of hybrid distributed generation system under voltage sag  

Science Conference Proceedings (OSTI)

In this paper, design of control strategy for hybrid fuel cell/energy storage distributed power generation system during voltage sag has been presented. The proposed control strategy allows hybrid distributed generation system works properly when a voltage ... Keywords: Energy storage, Fuel cell, Fuzzy sliding control, Hybrid distributed generation, Lyapanov, Neuro-fuzzy, Voltage sag

Amin Hajizadeh; Masoud Aliakbar Golkar

2010-12-01T23:59:59.000Z

115

Statement from Energy Secretary Samuel W. Bodman on the Nomination of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

the Nomination the Nomination of Thomas P. D'Agostino as Under Secretary for Nuclear Security and Administrator of NNSA Statement from Energy Secretary Samuel W. Bodman on the Nomination of Thomas P. D'Agostino as Under Secretary for Nuclear Security and Administrator of NNSA May 17, 2007 - 12:55pm Addthis "Today the President announced his intention to nominate Thomas P. D'Agostino as Under Secretary for Nuclear Security and Administrator of the National Nuclear Security Administration (NNSA). Tom served as NNSA's Acting Administrator for three months and as Deputy Administrator for Defense Programs for the past fourteen months. In these roles, Tom has done an outstanding job and has earned my full confidence. With this nomination, we are making NNSA even stronger and I am eager to

116

A Review Of Water Contents Of Nominally Anhydrous Natural Minerals In The  

Open Energy Info (EERE)

A Review Of Water Contents Of Nominally Anhydrous Natural Minerals In The A Review Of Water Contents Of Nominally Anhydrous Natural Minerals In The Mantles Of Earth, Mars And The Moon Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: A Review Of Water Contents Of Nominally Anhydrous Natural Minerals In The Mantles Of Earth, Mars And The Moon Details Activities (0) Areas (0) Regions (0) Abstract: Olivine, pyroxene and garnet are nominally anhydrous but can accommodate tens to hundreds of parts per million (ppm) H2O or "water" in the form of protons incorporated in defects in their mineral structure. This review concerns the amount of water in nominally anhydrous minerals from mantle and mantle-derived rocks: peridotites, eclogites, megacrysts, basalts and kimberlites. Trends between internal and external parameters

117

E. O. Lawrence Award Nominations | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

E. O. E. O. Lawrence Award Nominations News Featured Articles Science Headlines 2014 2013 2012 2011 2010 2009 2008 2007 2006 2005 Presentations & Testimony News Archives Contact Information Office of Science U.S. Department of Energy 1000 Independence Ave., SW Washington, DC 20585 P: (202) 586-5430 12.04.12 E. O. Lawrence Award Nominations The Office of Science is now accepting nominations for the 2013 E. O. Lawrence Award. Print Text Size: A A A Subscribe FeedbackShare Page Call for Nominations - 2013 E. O. Lawrence Award Nominations are sought for the 2013 E. O. Lawrence Awards beginning now through May 31, 2013. The outcome of the 2012 Lawrence Awards is anticipated to be announced soon. The Ernest Orlando Lawrence Award is bestowed by the Secretary of the U.S. Department of Energy to mid-career scientists and engineers in recognition

118

Enrico Fermi Award Nominations | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Enrico Fermi Enrico Fermi Award Nominations News Featured Articles Science Headlines 2014 2013 2012 2011 2010 2009 2008 2007 2006 2005 Presentations & Testimony News Archives Contact Information Office of Science U.S. Department of Energy 1000 Independence Ave., SW Washington, DC 20585 P: (202) 586-5430 12.04.12 Enrico Fermi Award Nominations The Office of Science is now accepting nominations for the 2013 Enrico Fermi Award. Print Text Size: A A A Subscribe FeedbackShare Page Call for Nominations - 2013 Enrico Fermi Award Nominations are sought for the 2013 Enrico Fermi Award beginning now through May 31, 2013. The outcome of the 2012 Fermi Award is anticipated to be announced soon. The Enrico Fermi Award is a Presidential award and one of the longest running and most prestigious science and technology awards given by the

119

Planning of distribution networks for medium voltage and low voltage.  

E-Print Network (OSTI)

??Determination of the placement and rating of transformers and feeders are the main objective of the basic distribution network planning. The bus voltage and the… (more)

Ziari, Iman

2011-01-01T23:59:59.000Z

120

3430 IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, VOL. 61, NO. 8, OCTOBER 2012 Experimental Validation of High-Voltage-Ratio  

E-Print Network (OSTI)

Validation of High-Voltage-Ratio Low-Input-Current-Ripple Converters for Hybrid Fuel Cell Supercapacitor

Simões, Marcelo Godoy

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

High voltage feedthrough bushing  

DOE Patents (OSTI)

A feedthrough bushing for a high voltage diode provides for using compression sealing for all sealing surfaces. A diode assembly includes a central conductor extending through the bushing and a grading ring assembly circumferentially surrounding and coaxial with the central conductor. A flexible conductive plate extends between and compressively seals against the central conductor and the grading ring assembly, wherein the flexibility of the plate allows inner and outer portions of the plate to axially translate for compression sealing against the central conductor and the grading ring assembly, respectively. The inner portion of the plate is bolted to the central conductor for affecting sealing. A compression beam is also bolted to the central conductor and engages the outer portion of the plate to urge the outer portion toward the grading ring assembly to obtain compression sealing therebetween.

Brucker, J.P.

1991-12-31T23:59:59.000Z

122

Substation voltage upgrading  

SciTech Connect

This report addresses specific issues to support sound yet not unduly conservative uprating practices for substations. The main parts of the report cover the insulation withstand and overvoltage protection aspects, environmental measurements, reliability criteria, and industry experience. First the insulation design concerns are addressed. Substation stress by a backflashover of the line insulation due to lightning in the vicinity of the substation is recognized as a critical stress. A representative part of a 550 kV BIL substation was erected at the EPRI High Voltage Transmission Research Center, where also a special test circuit was assembled to produce a fast front, slow tail (0.2/200 {mu}s) wave. The substation as well as some special configurations were tested for line-to-ground and line-to-line withstand. Computer studies were performed to complement the test results. A number of important conclusions was reached. The most prominent result in that the high frequency oscillations, as caused by reflections within the substation, do not effect the Critical Flashover Voltage (CFO). The present practice, based on the highest peak is therefore very conservative. The slow tail of the wave appears to dictate the CFO. An arrester model for computer studies to represent very fast as well as slow phenomena was derived. It is based on full scale arrester test data, made available in this project. The computer program to calculate arrester model parameters is also a part of the report. The electric environmental measurements are reported for the tested substation at the HVTRC and for the uprated substation of Public Service Company of Colorado, both before and after the uprating. The performance is satisfactory when corona free hardware is used. Insulation design criteria are analyzed based on substation reliability, the system viewpoint and consequences of the failure. Utility experience with uprated substations is reviewed.

Panek, J.; Elahi, H.; Lux, A.; Imece, A.F. (General Electric Co., Schenectady, NY (United States). Power Systems Engineering Dept.); LaPanse, R.A.; Stewart, J.R. (Public Service Co. of Colorado, Denver, CO (United States))

1992-04-01T23:59:59.000Z

123

High voltage series connected tandem junction solar battery  

DOE Patents (OSTI)

A high voltage series connected tandem junction solar battery which comprises a plurality of strips of tandem junction solar cells of hydrogenated amorphous silicon having one optical path and electrically interconnected by a tunnel junction. The layers of hydrogenated amorphous silicon, arranged in a tandem configuration, can have the same bandgap or differing bandgaps. The tandem junction strip solar cells are series connected to produce a solar battery of any desired voltage.

Hanak, Joseph J. (Lawrenceville, NJ)

1982-01-01T23:59:59.000Z

124

Voltage Vehicles | Open Energy Information  

Open Energy Info (EERE)

Sector Vehicles Product Voltage Vehicles is a nascent, full-service alternative fuel vehicle distributor specializing in the full spectrum of electric vehicles (EV) and...

125

Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect

An update is given on the work of the PV Quality Assurance Task Force; Group 3: studying the effects of humidity, temperature, and voltage bias.

Wohlgemuth, J.

2012-03-01T23:59:59.000Z

126

U.S. Nominal Cost per Natural Gas Well Drilled (Thousand Dollars...  

Annual Energy Outlook 2012 (EIA)

Natural Gas Well Drilled (Thousand Dollars per Well) U.S. Nominal Cost per Natural Gas Well Drilled (Thousand Dollars per Well) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5...

127

U.S. Nominal Cost per Foot of Natural Gas Wells Drilled (Dollars...  

Annual Energy Outlook 2012 (EIA)

Natural Gas Wells Drilled (Dollars per Foot) U.S. Nominal Cost per Foot of Natural Gas Wells Drilled (Dollars per Foot) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6...

128

U.S. Nominal Cost per Crude Oil Well Drilled (Thousand Dollars...  

Annual Energy Outlook 2012 (EIA)

Oil Well Drilled (Thousand Dollars per Well) U.S. Nominal Cost per Crude Oil Well Drilled (Thousand Dollars per Well) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6 Year-7...

129

U.S. Nominal Cost per Crude Oil, Natural Gas, and Dry Well Drilled...  

Annual Energy Outlook 2012 (EIA)

Oil, Natural Gas, and Dry Well Drilled (Thousand Dollars per Well) U.S. Nominal Cost per Crude Oil, Natural Gas, and Dry Well Drilled (Thousand Dollars per Well) Decade Year-0...

130

U.S. Nominal Cost per Foot of Crude Oil Wells Drilled (Dollars...  

Gasoline and Diesel Fuel Update (EIA)

Oil Wells Drilled (Dollars per Foot) U.S. Nominal Cost per Foot of Crude Oil Wells Drilled (Dollars per Foot) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6 Year-7 Year-8...

131

U.S. Nominal Cost per Dry Well Drilled (Thousand Dollars per...  

Annual Energy Outlook 2012 (EIA)

Dry Well Drilled (Thousand Dollars per Well) U.S. Nominal Cost per Dry Well Drilled (Thousand Dollars per Well) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6 Year-7...

132

U.S. Nominal Cost per Foot of Crude Oil, Natural Gas, and Dry...  

Annual Energy Outlook 2012 (EIA)

Oil, Natural Gas, and Dry Wells Drilled (Dollars per Foot) U.S. Nominal Cost per Foot of Crude Oil, Natural Gas, and Dry Wells Drilled (Dollars per Foot) Decade Year-0 Year-1...

133

University Academic Advising Awards Nomination Process Please follow the steps below in order to access and submit a nomination for the university advising awards.  

E-Print Network (OSTI)

" represents the search term(s) you entered. However, you will see the site you just joined if you click the My. If you'd like to join any of them, click . E. To search for a particular site or group of sites: 1. Enter your search terms in the Search box. In order to submit your advising nomination form you must find

Virginia Tech

134

Strain-optic voltage monitor  

DOE Patents (OSTI)

A voltage monitor which uses the shift in absorption edge of crystalline material to measure strain resulting from electric field-induced deformation of piezoelectric or electrostrictive material, providing a simple and accurate means for measuring voltage applied either by direct contact with the crystalline material or by subjecting the material to an electric field.

Weiss, J.D.

1995-12-31T23:59:59.000Z

135

Two terminal line voltage thermostat  

Science Conference Proceedings (OSTI)

A two terminal line voltage thermostat includes a switch which effectively connects line voltage to a heater load. The entire process is controlled by an integrated circuit microcontroller which is powered by a rectified voltage from a transformer secondary connected to a primary which is in series with the heater load. Backup battery power is provided to maintain limited functions of the microcontroller in the event of overall power loss. The microcontroller is programmed to meet the temperature sensing and control requirements specific to a two terminal electric baseboard heating installation. 7 figs.

Stalsberg, K.J.; Ingalls, J.E.; Hoglund, S.R.

1995-10-10T23:59:59.000Z

136

Distribution of Local Open-Circuit Voltage on Amorphous and Nanocrystalline Mixed-Phase Si:H and SiGe:H Solar Cells (Poster)  

DOE Green Energy (OSTI)

By combining SKPM and AFM, they have developed a method to measure the local V{sub oc} distribution in mixed-phase solar cells. The results clearly show the nanocrystalline aggregation. The V{sub oc} is smaller in the nanocrystalline aggregates than in the surrounding amorphous matrix, and the transition from the low to high V{sub oc} is a gradual change. Although there are some lateral charge redistributions, a clear distinction between the amorphous and nanocrystalline regions has been observed. The current SKPM results and previous C-AFM results provide extra support for the two-diode model for explaining the carrier transport in the mixed-phase solar cells.

Jiang, C.-S.; Moutinho, H. R.; Al-Jassim, M. M.; Kazmerski, L. L.; Yan, B.; Yang, J.; Guha, S.

2006-05-01T23:59:59.000Z

137

Definition: Automated Voltage Regulators | Open Energy Information  

Open Energy Info (EERE)

Regulators Regulators Jump to: navigation, search Dictionary.png Automated Voltage Regulators Voltage regulators are transformers that can increase or decrease the voltage on a distribution circuit to help keep the voltage within a pre-determined band. Unlike capacitor banks, voltage regulators cannot adjust power factor. These devices typically monitor the voltage at the location where they are connected, and compare it to a programmed set point. If the voltage deviates too far from the set point, the voltage regulator can increase or decrease its output voltage by moving the tap on the secondary side up or down. An automated voltage regulator can operate with remote control signals, or in concert with other area voltage control devices, to help regulate distribution voltage in a coordinated fashion.

138

High-voltage-compatible, fully depleted CCDs  

E-Print Network (OSTI)

result of this high-voltage requirement, we have taken a di?voltage is necessary in order to meet the PSF requirementsrequirements for SNAP have resulted in a need to operate at substrate bias voltages

2006-01-01T23:59:59.000Z

139

Chapter 4 - Understanding Voltage Sags  

Science Conference Proceedings (OSTI)

This chapter of the EPRI Solutions PQ Encyclopedia provides information for understanding the voltage sag, which is the single most potent cause of end user power quality (PQ) problems.

2005-12-31T23:59:59.000Z

140

Nominations open for $250,000 Multimedia Clean Energy prizes | OpenEI  

Open Energy Info (EERE)

Nominations open for $250,000 Multimedia Clean Energy prizes Nominations open for $250,000 Multimedia Clean Energy prizes Home > Groups > Utility Rate Graham7781's picture Submitted by Graham7781(1992) Super contributor 2 October, 2012 - 13:01 American Clean Skies Foundation clean energy Energy Visions Prize OpenEI WASHINGTON, D.C. (September 27, 2012) - Representatives of the $250,000 Energy Visions Prize (EVP) competition will attend the Cleanweb Hackathons in NYC, Houston and SXSW Eco in Austin to preview innovative clean energy apps and encourage nominations. The EVP rewards innovative software and video makers who advance clean energy solutions. Based on growing national interest in the competition, the prize sponsor, the American Clean Skies Foundation (ACSF), also announced that it has extended the submission deadline until December 14, 2012.

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

A CMOS threshold voltage reference source for very-low-voltage applications  

Science Conference Proceedings (OSTI)

This paper describes a CMOS voltage reference that makes use of weak inversion CMOS transistors and linear resistors, without the need for bipolar transistors. Its operation is analogous to the bandgap reference voltage, but the reference voltage is ... Keywords: Threshold voltage, Ultra-low-power, Very-low-voltage, Voltage reference

Luis H. C. Ferreira; Tales C. Pimenta; Robson L. Moreno

2008-12-01T23:59:59.000Z

142

Surge voltage suppression in residential power circuits  

Science Conference Proceedings (OSTI)

... Tran- sients in Low Voltage Supply Systems,'' The ... a high-voltage transformer for an oil furnace ... of service entrance SPD of 1960-1970 vintage were ...

2013-05-17T23:59:59.000Z

143

Automated Voltage Control in LHCb  

E-Print Network (OSTI)

LHCb is one of the 4 LHC experiments. In order to ensure the safety of the detector and to maximize efficiency, LHCb needs to coordinate its own operations, in particular the voltage configuration of the different subdetectors, according to the accelerator status. A control software has been developed for this purpose, based on the Finite State Machine toolkit and the SCADA system used for control throughout LHCb (and the other LHC experiments). This software permits to efficiently drive both the Low Voltage (LV) and High Voltage (HV) systems of the 10 different sub-detectors that constitute LHCb, setting each sub-system to the required voltage (easily configurable at run-time) based on the accelerator state. The control software is also responsible for monitoring the state of the Sub-detector voltages and adding it to the event data in the form of status-bits. Safe and yet flexible operation of the LHCb detector has been obtained and automatic actions, triggered by the state changes of the ...

Granado Cardoso, L; Jacobsson, R

2011-01-01T23:59:59.000Z

144

Multilevel cascade voltage source inverter with seperate DC sources  

SciTech Connect

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

145

Multilevel cascade voltage source inverter with seperate DC sources  

DOE Patents (OSTI)

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

Peng, Fang Zheng (Knoxville, TN); Lai, Jih-Sheng (Blacksburg, VA)

2002-01-01T23:59:59.000Z

146

Multilevel cascade voltage source inverter with separate DC sources  

DOE Patents (OSTI)

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-06-24T23:59:59.000Z

147

U.S. Nominal Cost per Foot of Dry Wells Drilled (Dollars per...  

Annual Energy Outlook 2012 (EIA)

Dry Wells Drilled (Dollars per Foot) U.S. Nominal Cost per Foot of Dry Wells Drilled (Dollars per Foot) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6 Year-7 Year-8 Year-9...

148

A Nominal Filter for Web Search Snippets: Using the Web to Identify Members of Latin  

E-Print Network (OSTI)

A Nominal Filter for Web Search Snippets: Using the Web to Identify Members of Latin America. This paper presents efforts aimed at using Natural Language Engineering (NLE) techniques to solve of three Latin American countries: Uruguay, Argentina and Colombia. An NLE system is under construction

Turner, William

149

Application / Nomination Form TIAA-CREF Ruth Simms Hamilton Graduate Merit Fellowship  

E-Print Network (OSTI)

Application / Nomination Form for TIAA-CREF Ruth Simms Hamilton Graduate Merit Fellowship 2013 the subject line reads "TIAA-CREF Fellowship Application ­ (applicant's name)". Questions? Please contact Dean Klomparens (kklompar@grd.msu.edu). The Fellowship award will be announced by mid-January, 2014. The TIAA

Liu, Taosheng

150

Portec Voltage Regulators: for Emergency Diesel Generators  

Science Conference Proceedings (OSTI)

This report contains information to help utilities address emergency diesel generator voltage regulator issues.

2004-12-15T23:59:59.000Z

151

Fiber-optic voltage sensor  

DOE Patents (OSTI)

A fiber optic voltage sensor is described which includes a source of light, a reference fiber for receiving a known percentage of the light and an electrostrictive element having terminals across which is applied, a voltage to be measured. The electrostrictive element is responsive to the applied voltage to assume an altered physical state. A measuring fiber also receives a known percentage of light from the light source and is secured about the electrostrictive element. The measuring fiber is provided with a cladding and exhibits an evanescent wave in the cladding. The measuring fiber has a known length which is altered when the electrostrictive element assumes its altered physical state. A differential sensor is provided which senses the intensity of light in both the reference fiber and the measuring fiber and provides an output indicative of the difference between the intensities.

Wood, C.B.

1990-12-31T23:59:59.000Z

152

A voltage controlled current source  

DOE Patents (OSTI)

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoampers to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, G.M.

1990-12-21T23:59:59.000Z

153

Fiber-optic voltage sensor  

DOE Patents (OSTI)

A fiber optic voltage sensor is described which includes a source of light, a reference fiber for receiving a known percentage of the light and an electrostrictive element having terminals across which is applied, a voltage to be measured. The electrostrictive element is responsive to the applied voltage to assume an altered physical state. A measuring fiber also receives a known percentage of light from the light source and is secured about the electrostrictive element. The measuring fiber is provided with a cladding and exhibits an evanescent wave in the cladding. The measuring fiber has a known length which is altered when the electrostrictive element assumes its altered physical state. A differential sensor is provided which senses the intensity of light in both the reference fiber and the measuring fiber and provides an output indicative of the difference between the intensities.

Wood, C.B.

1990-01-01T23:59:59.000Z

154

NOMINATION FORM  

Science Conference Proceedings (OSTI)

... secondary technical training model for public schools in cyber security, biomedical and engineering, including aerospace, biotech, digital, civil and ...

2013-04-17T23:59:59.000Z

155

Ancillary service details: Voltage control  

SciTech Connect

Voltage control is accomplished by managing reactive power on an alternating-current power system. Reactive power can be produced and absorbed by both generation and transmission equipment. Reactive-power devices differ substantially in the magnitude and speed of response and in their capital costs. System operators, transmission owners, generators, customers, power marketers, and government regulators need to pay close attention to voltage control as they restructure the U.S. electricity industry. Voltage control can affect reliability and commerce in three ways: (1) Voltages must be maintained within an acceptable range for both customer and power-system equipment to function properly. (2) The movement of reactive power consumes transmission resources, which limits the ability to move real power and worsens congestion. (3) The movement of reactive power results in real-power losses. When generators are required to supply excessive amounts of reactive power, their real-power production must be curtailed. These opportunity costs are not currently compensated for in most regions. Current tariffs are based on embedded costs. These embedded-cost tariffs average about $0.51/MWh, equivalent to $1.5 billion annually for the United States as a whole. Although this cost is low when compared with the cost of energy, it still aggregates to a significant amount of money. This report takes a basic look at why the power system requires reactive power (an appendix explains the fundamentals of real and reactive power). The report then examines the various types of generation and transmission resources used to supply reactive power and to control voltage. Finally it discusses how these resources are deployed and paid for in several reliability regions around the country. As the U.S. electricity industry is restructured, the generation, transmission, and system-control equipment and functions that maintain voltages within the appropriate ranges are being deintegrated.

Kirby, B.; Hirst, E.

1997-12-01T23:59:59.000Z

156

Probabilistic voltage assessment and VAR compensation  

SciTech Connect

The system voltage profile subject to system elements' forced outage is accessed. Two system voltage reliability indexes are evaluated: the loss of voltage probability, and the expected voltage violation. A similar set of two voltage reliability indexes are also calculated for every load bus in the system. A simple VAR compensation approach is introduced. It enhances the voltage profile assuming a maximum of three overlapping element outages can occur. For purposes of demonstration, the system and load bus voltage reliability indexes are calculated for the AEP 30-bus system. Results of applying the proposed VAR compensation scheme to the 30-bus system are also presented and discussed.

Sharaf, T.A.M.; Berg, G.J.

1988-01-01T23:59:59.000Z

157

Vehicle Details And Battery Specifications  

NLE Websites -- All DOE Office Websites (Extended Search)

Nominal Cell Voltage: 3.6 V Number of Electric Machines: 1 Nominal System Voltage: 144 V Motor: 17 kW (peak), Permanent Magnet, Liquid cooled Rated Pack Capacity: 4.7 Ah Maximum...

158

TRANSISTOR HIGH VOLTAGE POWER SUPPLY  

DOE Patents (OSTI)

High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

Driver, G.E.

1958-07-15T23:59:59.000Z

159

High Voltage Test Apparatus for a Neutron EDM Experiment and Lower Limit on the Dielectric Strength of Liquid Helium at Large Volumes  

E-Print Network (OSTI)

A new search for a permanent electric dipole moment (EDM) of the neutron is underway using ultracold neutrons produced and held in a bath of superfluid helium. Attaining the target sensitivity requires maintaining an electric field of several tens of kilovolts per centimeter across the experimental cell, which is nominally 7.5 cm wide and will contain about 4 liters of superfluid. The electrical properties of liquid helium are expected to be sufficient to meet the design goals, but little is known about these properties for volumes and electrode spacings appropriate to the EDM experiment. Furthermore, direct application of the necessary voltages from an external source to the experimental test cell is impractical. An apparatus to amplify voltages in the liquid helium environment and to test the electrical properties of the liquid for large volumes and electrode spacings has been constructed. The device consists of a large-area parallel plate capacitor immersed in a 200 liter liquid helium dewar. Preliminary results show the breakdown strength of normal state liquid helium is at least 90 kV/cm at these volumes, at the helium vapor pressure corresponding to 4.38 K. These fields hold for more than 11 hours with leakage currents less than 170 pA (about 20% of the maximum tolerable in the EDM experiment). The system is also found to be robust against anticipated radiation backgrounds. Preliminary results for superfluid show that fields of at least 30 kV/cm can be sustained at the volumes required for the EDM experiment, about 60% of the design goal. These results are likely limited by the low pressure that must be maintained above the superfluid bath.

J. C. Long; P. D. Barnes; J. G. Boissevain; D. J. Clark; M. D. Cooper; J. J. Gomez; S. K. Lamoreaux; R. E. Mischke; S. I. Penttila

2006-03-27T23:59:59.000Z

160

Voltage unbalance effects on induction motor performance  

Science Conference Proceedings (OSTI)

The reliability of electric drives and driven motors depends on the quality of the power supply voltage especially in the critical industrial process. In this work, a theoretical study of the effects of voltage unbalances, sags and swells on induction ... Keywords: efficiency, power losses and derating factor, sags, symmetrical components, voltage unbalance

L. Refoufi; H. Bentarzi; F. Z. Dekhandji

2006-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Influence of voltage drop to electric drive with induction motor and voltage sourced inverter  

Science Conference Proceedings (OSTI)

This paper solves problematic of immunity from the voltage drop of the power supply of the electric drive with induction motor with Voltage-Fed inverter. There are reflected opportune control algorithms for the quickly to change of working regime from ... Keywords: electric drive with induction motor, electric drive with voltage sourced inverter, voltage drop

P. Beneš; J. Fo?t; M. Pittermann

2011-09-01T23:59:59.000Z

162

High voltage RF feedthrough bushing  

DOE Patents (OSTI)

Described is a multi-element, high voltage radio frequency bushing for trmitting RF energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.

Grotz, Glenn F. (Huntington Station, NY)

1984-01-01T23:59:59.000Z

163

Low power, scalable multichannel high voltage controller  

DOE Patents (OSTI)

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

2006-03-14T23:59:59.000Z

164

Low power, scalable multichannel high voltage controller  

DOE Patents (OSTI)

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

2008-03-25T23:59:59.000Z

165

Dynamic Voltage Regulation Using Distributed Energy Resources  

Science Conference Proceedings (OSTI)

Many distributed energy resources (DE) are near load centres and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide ancillary services such as voltage regulation, nonactive power compensation, and power factor correction. A synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Voltage control schemes of the inverter and the synchronous condenser are developed. The experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously, while the dynamic response of the inverter is faster than the synchronous condenser; and that integrated voltage regulation (multiple DE perform voltage regulation) can increase the voltage regulation capability, increase the lifetime of the equipment, and reduce the capital and operation costs.

Xu, Yan [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL

2007-01-01T23:59:59.000Z

166

Nominal Exchange Rate Regimes and Relative Price Dispersion: On the Importance of Nominal Exchange Rate Volatility for the Width of the Border †  

E-Print Network (OSTI)

Based on a broad set of regional aggregated and disaggregated consumer price index (CPI) data from major industrialized countries in Asia, North America and Europe we are examining the role that national borders play for goods market integration. In line with the existing literature we find that intra-national markets are better integrated than international market. Additionally, our results show that there is a large ’ocean ’ effect, i.e., inter-continental markets are significantly more segmented than intra-continental markets. To examine the impact of the establishment of the European Monetary Union (EMU) on integration, we are splitting our sample in a pre-EMU and EMU sample. We find that border effects across EMU countries reduce by about 80 % to 90 % after 1999 whereas border estimates across non-EMU countries have basically not changed. Since globally effective factors have affected all countries in our sample similarly and major integration efforts across EMU countries were made before 1999, we suggest that most of the reduction in EMU border estimates has been ’nominal’. Panel unit root evidence shows that the observed large differences in integration across intra- and inter-continental markets remain valid in the longrun. This finding implies that real factors are responsible for the documented segmentations across our sample countries.

Guenter W. Beck

2003-01-01T23:59:59.000Z

167

Characterisation of the VELO High Voltage System  

E-Print Network (OSTI)

The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; verification of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence that the high voltage system can be safely used and demonstrate that low noise is produced by the power supplies. LHCb Public Note, LHCb-2008-009Contents 1

Barinjaka Rakotomiaramanana; Chris Parkes; Lars Eklund

2008-01-01T23:59:59.000Z

168

The effect of DVR location for enhancing voltage sag  

Science Conference Proceedings (OSTI)

Recently, Dynamic Voltage Restorer (DVR) has become a popular power electronic device as a protection for sensitive loads from voltage sag. Voltage sag widely known as one of the major problem in power quality, it is defined as a short reduction of voltage ... Keywords: dynamic voltage restorer, power quality, voltage sag

Rohanim Ibrahim; Ahmed M. A. Haidar; M. Zahim; Herbert Iu

2010-03-01T23:59:59.000Z

169

Definition: Operating Voltage | Open Energy Information  

Open Energy Info (EERE)

Voltage Voltage Jump to: navigation, search Dictionary.png Operating Voltage The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related; also, the effective (root-mean-square) potential difference between any two conductors or between a conductor and the ground. The actual voltage of the circuit may vary somewhat above or below this value.[1] Related Terms system References ↑ Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Operating_Voltage&oldid=480559" Categories: Definitions ISGAN Definitions What links here Related changes

170

Emergency Diesel Generator Voltage Regulator Guidelines  

Science Conference Proceedings (OSTI)

This product kit, containing six separate documents, provides information to help utilities address emergency diesel generator voltage regulator issues and maintenance.

2005-12-20T23:59:59.000Z

171

Characterisation of the VELO High Voltage System  

E-Print Network (OSTI)

The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; vercation of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence th...

Rakotomiaramanana, B; Eklund, L

2008-01-01T23:59:59.000Z

172

Characterisation of the VELO High Voltage System  

E-Print Network (OSTI)

The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; verification of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence...

Rakotomiaramanana, B; Eklund, L

2008-01-01T23:59:59.000Z

173

Group 3: Humidity, Temperature, and Voltage (Presentation)  

DOE Green Energy (OSTI)

Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-05-01T23:59:59.000Z

174

Voltage Source Converter Technology for Offshore Grids.  

E-Print Network (OSTI)

??This master thesis has investigated the possible application of voltage source converters (VSC) for the interconnection of offshore installations, i.e. wind farms and petroleum platforms,… (more)

Vormedal, Pål Kristian Myhrer

2010-01-01T23:59:59.000Z

175

Quantum Voltage System Development and Dissemination  

Science Conference Proceedings (OSTI)

... of the unit of electric potential difference, the volt, and precise techniques for measuring voltage are essential to the electrical ... Facilities/Tools Used: ...

2012-11-14T23:59:59.000Z

176

Advanced Voltage Control Strategies for High Penetration of Distributed Generation  

Science Conference Proceedings (OSTI)

This research addresses advanced voltage control strategies for inverter-connected distributed generation. The emphasis is on photovoltaic (PV) generation, and results also apply to distributed wind, fuel cells, micro-turbines, and battery systems that are connected to the grid through an inverter. In related work, the Electric Power Research Institute (EPRI) identified a set of high-priority functions for distributed generation. These included reactive power control such as intelligent and autonomous vo...

2010-12-31T23:59:59.000Z

177

Aalborg Universitet Mitigation of Voltage Sags in CIGRE Low Voltage Distribution Network  

E-Print Network (OSTI)

software version 15.0. Index Terms--Wind Turbine Generator (WTG), Photovoltaic (PV), Voltage Source of voltage sags. I. INTRODUCTION Power quality, reliability and stability are the prime requirement of modern

Bak-Jensen, Birgitte

178

Satellite power system (SPS). Rectenna siting: availability and distribution of nominally eligible sites  

DOE Green Energy (OSTI)

Siting of 60 ground receiving stations (rectennas) for the SPS may pose a problem due to the large area per rectenna (15,000 hectares, 38,000 acres) and numerous siting constraints. This study analyzes areas potentially eligible for rectenna sites by mapping, at a national scale, those conditions which would preclude rectenna construction. These exclusion variables which reflect restricted lands, topography, safety, national policy and electromagnetic (microwave) effects, have been computer encoded and tabulated. Subsequent analysis of the nine electric power planning regions that make up the contiguous states indicate an apparently adequate number of nominally eligible sites in all regions in comparison to projected electrical generation. Eligibility in this context means only that areas were not excluded in this national level analysis; more detailed investigation may reveal purely local constraints or smaller scale exclusions. A second major qualification relates to small isolated eligible areas. Eliminating individual eligible clusters with less than nine times the area of one rectenna eliminates much of the Eastern US; a four-to-one adjacent eligible area test poses no such problem. An independant study of the placement of 60 nominal sites in relation to projected load centers reveals that, even with modest transmission distances, the supply of eligible areas is not a key constraint, except perhaps in the Mid-Atlantic (Electric Reliability) Council Region. Even when several less critical (potential) exclusions are considered, more than 19% of the US is eligible; every region except Mid-Atlantic has at least 50 times an many eligible sites as are required.

Not Available

1980-11-01T23:59:59.000Z

179

Low voltage ride-through capability improvement of wind power generation using dynamic voltage restorer  

Science Conference Proceedings (OSTI)

Recently, the total amount of generation from wind power plants has been increased all over the world. In this situation, a large amount of disconnection of wind generation may give a serious influence in the power system. Consequently, Low Voltage Ride-Through ... Keywords: dynamic voltage restorer, energy storage, fault ride-through, fixed-speed induction generator, low voltage ride-through, voltage sag, wind power generation

Naohiro Hasegawa; Teruhisa Kumano

2010-02-01T23:59:59.000Z

180

Voltage Stability Studies for Southern Company Services  

Science Conference Proceedings (OSTI)

This report describes a study conducted under an EPRI Tailored Collaboration project to develop and demonstrate procedures for the assessment of voltage security of the Southern Electric System (SES). The contractor used EPRI steady-state analysis tools including VSTAB (Voltage STABility assessment program) to assess stability margins and verified them using EPRI dynamic tools including ETMSP (Extended Transient / Mid-term Stability Program).

1997-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Voltage regulation in linear induction accelerators  

DOE Patents (OSTI)

Improvement in voltage regulation in a Linear Induction Accelerator wherein a varistor, such as a metal oxide varistor when it is placed in parallel with the beam accelerating cavity and the magnetic core. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance.

Parsons, W.M.

1991-03-19T23:59:59.000Z

182

Voltage regulation in linear induction accelerators  

DOE Patents (OSTI)

Improvement in voltage regulation in a linear induction accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core is disclosed. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance. 4 figs.

Parsons, W.M.

1992-12-29T23:59:59.000Z

183

Capabilities of the High Voltage Stress Test System at the Outdoor Test Facility  

DOE Green Energy (OSTI)

We illustrate the capabilities of the High Voltage Stress Test (HVST) which operates continuously in the array field east of the Outdoor Test Facility at the National Renewable Energy Laboratory. Because we know that photovoltaic (PV) modules generating electrical power in both residential and utility-scale array installations will develop high-voltage biases approaching 600 VDC and 1,000 VDC, respectively, we expect such high voltages will result in current leakage between cells and ground, typically through the frames or mounts. We know that inevitably such leakage currents are capable of producing electrochemical corrosion that adversely impacts long-term module performance. With the HVST, we stress or operate PV modules under high-voltage bias, to characterize their leakage currents under all prevailing ambient conditions and assess performance changes emanating from high-voltage stress. We perform this test both on single modules and an active array.

del Cueto, J. A.; Trudell, D.; Sekulic, W.

2005-11-01T23:59:59.000Z

184

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents (OSTI)

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

1994-06-28T23:59:59.000Z

185

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents (OSTI)

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components.

Duckworth, Douglas C. (Knoxville, TN); Marcus, R. Kenneth (Clemson, SC); Donohue, David L. (Vienna, AT); Lewis, Trousdale A. (Oak Ridge, TN)

1994-01-01T23:59:59.000Z

186

Corona and Motor Voltage Interim Report  

SciTech Connect

It has been suggested that to meet the FreedomCAR objectives for cost, size, weight, efficiency, and reliability higher buss voltages be utilized in HEV and FC automotive applications. The reasoning is that since electric power is equal to the product of voltage and current for a given power a higher voltage and lower current would result in smaller cable and inverter switching components. Consequently, the system can be lighter and smaller. On the other hand, higher voltages are known to require better and thicker electrical insulation that reduce the available slot area for motor windings. One cause of slow insulation breakdown is corona that gradually erodes the insulation and shortens the life expectancy of the motor. This study reports on the results of a study on corona initiating voltages for mush-wound and bobbin-wound stators. A unique testing method is illustrated.

Hsu, J.S.

2005-05-06T23:59:59.000Z

187

Performance of a voltage peak detection-based flickermeter  

Science Conference Proceedings (OSTI)

Voltage fluctuations and rapid voltage changes lead to lamps flickering and disturbance of visual perception may occur consequently. For evaluation of the flicker severity level by means of voltage measurement there was developed an instrument called ... Keywords: Matlab Simulink, flickermeter, interharmonics, performance analysis, voltage fluctuation, voltage peak detection

Jiri Drapela

2009-12-01T23:59:59.000Z

188

SRAM leakage suppression by minimizing standby supply voltage  

E-Print Network (OSTI)

Suppressing the leakage current in memories is critical in low-power design. By reducing the standby supply voltage (VDD) to its limit, which is the Data Retention Voltage (DRV), leakage power can be substantially reduced. This paper explores how low DRV can be in a standard low leakage SRAM module and analyzes how DRV is affected by parameters such as process variations, chip temperature, and transistor sizing. An analytical model for DRV as a function of process and design parameters is presented, and forms the base for further design space explorations. This model is verified using simulations as well as measurements from a 4KB SRAM chip in a 0.13?m technology. It is demonstrated that an SRAM cell state can be preserved at sub-300mV standby V DD, with more than 90 % leakage power savings. 1.

Huifang Qin; Yu Cao; Dejan Markovic; Andrei Vladimirescu; Jan Rabaey

2004-01-01T23:59:59.000Z

189

Voltage controlled spintronics device for logic applications.  

SciTech Connect

We consider logic device concepts based on our previously proposed spintronics device element whose magnetization orientation is controlled by application of a bias voltage instead of a magnetic field. The basic building block is the voltage-controlled rotation (VCR) element that consists of a four-layer structure--two ferromagnetic layers separated by both nanometer-thick insulator and metallic spacer layers. The interlayer exchange coupling between the two ferromagnetic layers oscillates as a function of applied voltage. We illustrate transistor-like concepts and re-programmable logic gates based on VCR elements.

Bader, S. D.; You, C.-Y.

1999-09-03T23:59:59.000Z

190

Voltage controlled spintronic devices for logic applications  

SciTech Connect

We consider logic device concepts based on our previously proposed spintronics device element whose magnetization orientation is controlled by application of a bias voltage instead of a magnetic field. The basic building block is the voltage-controlled rotation (VCR) element that consists of a four-layer structure--two ferromagnetic layers separated by both nanometer-thick insulator and metallic spacer layers. The interlayer exchange coupling between the two ferromagnetic layers oscillates as a function of applied voltage. We illustrate transistorlike concepts and reprogrammable logic gates based on VCR elements. (c) 2000 American Institute of Physics.

You, Chun-Yeol [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Bader, S. D. [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

2000-05-01T23:59:59.000Z

191

Interphase power controller with voltage injection  

Science Conference Proceedings (OSTI)

This paper introduces a new family of Interphase Power Controllers (IPC) based on the principle of voltage injection commonly used in phase-shifting transformers (PST). The voltage injection IPC exhibits power (active and reactive) control characteristics similar to previously defined IPC's and retains their inherent qualities: passive control, short circuit limitation and voltage decoupling. It also provides more flexibility for the adjustment of the operating points. Two promising topologies are described in more detail. One of them offers the potential of retrofitting existing phase-shifting transformers into full-fledged IPC's.

Beauregard, F.; Brochu, J.; Morin, G.; Pelletier, P. (Centre d'Innovation sur le Transport d'Energie du Quebec, Varennes, Quebec (Canada))

1994-10-01T23:59:59.000Z

192

Social performance as a predictor of peer nominations in newly formed groups: a short-term longitudinal study  

E-Print Network (OSTI)

We assessed the predictive ability of social performance as measured by the Checklist of Adolescent Problem Situations (CAPS; Cavell & Kelley, 1995) for peer nominations of likability and four behavioral dimensions. The CAPS contains seven scales: Make Friends, Keep Friends, Parents, Siblings, School, work, and Problem Behavior. High scores on these scales are indicative of inadequacy in functioning in that area. Subjects were academically atrisk adolescents who participated in a university-based summer enhancement program. The subjects were previously unacquainted, allowing us to control for the effects of reputation. The CAPS was administered prior to the program and peer nominations were obtained at the end of 8 weeks. Subjects who received higher scores on the Keep Friends and Problem Behavior scales were more likely to receive fewer nominations of friendliness than were subjects whose scores were low on these scales. Social impact scores, determined by nominations of likability, were significantly positively correlated with scores on the Make Friends scale. Rejected adolescents had greater difficulty in work-related situations than either popular or neglected adolescents. The most interesting finding was an interaction effect between sociometric status and gender on the Sibling scale. The clinical and research implications of these findings are discussed.

Kinnee, Chandra Leigh Spencer

1995-01-01T23:59:59.000Z

193

Life of Plant Activity Estimates for a Nominal 1000 MWe Pressurized Water Reactor and Boiling Water Reactor  

Science Conference Proceedings (OSTI)

Decommissioning nuclear power plant and disposal site managers must understand the radioactive source term of a nuclear power plant to effectively manage disposition of these materials. This study estimates the radioactive source term from nominal 1000 MWe pressurized water and boiling water reactors to support decisions related to radioactive waste storage, processing, and disposal through decommissioning.BackgroundThis study examines the radionuclide ...

2012-12-05T23:59:59.000Z

194

System for increasing corona inception voltage of insulating oils  

DOE Patents (OSTI)

The Corona Inception Voltage of insulating oils is increased by repetitive cycles of prestressing the oil with a voltage greater than the corona inception voltage, and either simultaneously or serially removing byproducts of corona by evacuation and heating the oil.

Rohwein, Gerald J. (Albuquerque, NM)

1998-01-01T23:59:59.000Z

195

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, R.S.

1985-08-05T23:59:59.000Z

196

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, Ronald S. (Livermore, CA)

1987-01-01T23:59:59.000Z

197

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile. 2 figs.

Hawke, R.S.

1987-11-17T23:59:59.000Z

198

High-voltage-compatible, fully depleted CCDs  

SciTech Connect

We describe charge-coupled device (CCD) developmentactivities at the Lawrence Berkeley National Laboratory (LBNL).Back-illuminated CCDs fabricated on 200-300 mu m thick, fully depleted,high-resistivity silicon substrates are produced in partnership with acommercial CCD foundry.The CCDs are fully depleted by the application ofa substrate bias voltage. Spatial resolution considerations requireoperation of thick, fully depleted CCDs at high substrate bias voltages.We have developed CCDs that are compatible with substrate bias voltagesof at least 200V. This improves spatial resolution for a given thickness,and allows for full depletion of thicker CCDs than previously considered.We have demonstrated full depletion of 650-675 mu m thick CCDs, withpotential applications in direct x-ray detection. In this work we discussthe issues related to high-voltage operation of fully depleted CCDs, aswell as experimental results on high-voltage-compatible CCDs.

Holland, Stephen E.; Bebek, Chris J.; Dawson, Kyle S.; Emes, JohnE.; Fabricius, Max H.; Fairfield, Jessaym A.; Groom, Don E.; Karcher, A.; Kolbe, William F.; Palaio, Nick P.; Roe, Natalie A.; Wang, Guobin

2006-05-15T23:59:59.000Z

199

Assessment of Voltage Security Methods and Tools  

Science Conference Proceedings (OSTI)

To ensure voltage-secure operation of a power system, VAR control devices must be optimally placed and operated. This project assessed tools and methods that claim to help utilities meet these needs and recommended specific enhancements to these tools.

1995-10-26T23:59:59.000Z

200

Superconducting Low Voltage Direct Current (LVDC) Networks  

Science Conference Proceedings (OSTI)

A low voltage dc superconducting distribution network is a challenging future opportunity for power distribution. This report presents a scheme for a superconducting, parallel- connected, multiterminal dc transmission system.

1994-04-27T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Spark gap with low breakdown voltage jitter  

SciTech Connect

Novel spark gap devices and electrodes are disclosed. The novel spark gap devices and electrodes are suitable for use in a variety of spark gap device applications. The shape of the electrodes gives rise to local field enhancements and reduces breakdown voltage jitter. Breakdown voltage jitter of approximately 5% has been measured in spark gaps according the invention. Novel electrode geometries and materials are disclosed.

Rohwein, Gerald J. (Albuquerque, NM); Roose, Lars D. (Albuquerque, NM)

1996-01-01T23:59:59.000Z

202

Voltage Control Optimization to Improve Transmission Efficiency  

Science Conference Proceedings (OSTI)

An optimal power flow solution is unique from a conventional power flow solution in that an objective function and user-specified constraints are enforced and satisfied to reach a valid solution. This report presents an analytical study on the optimization of power flow in order to minimize reactive power losses via the modification of generator voltage schedules and transmission switched shunt status. The study examines the potential benefits and applicability of near-real-time voltage control ...

2012-11-08T23:59:59.000Z

203

Modular high voltage power supply for chemical analysis  

DOE Patents (OSTI)

A high voltage power supply for use in a system such as a microfluidics system, uses a DC--DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC--DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2007-01-09T23:59:59.000Z

204

Modular high voltage power supply for chemical analysis  

DOE Patents (OSTI)

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2008-07-15T23:59:59.000Z

205

Appendix C: California ISO Real Time Voltage Security Assessment...  

NLE Websites -- All DOE Office Websites (Extended Search)

C: California ISO Real Time Voltage Security Assessment (VSA) Prototype Functional SpecificationsPrototype Development Title Appendix C: California ISO Real Time Voltage Security...

206

Appendix B: California ISO Real Time Voltage Security Assessment...  

NLE Websites -- All DOE Office Websites (Extended Search)

B: California ISO Real Time Voltage Security Assessment (VSA) Summary Report Title Appendix B: California ISO Real Time Voltage Security Assessment (VSA) Summary Report Publication...

207

Appendix A: California ISO Real Time Voltage Security Assessment...  

NLE Websites -- All DOE Office Websites (Extended Search)

A: California ISO Real Time Voltage Security Assessment (VSA) Project: Summary of Survey Results on Methodologies for use in Real-Time Voltage Security Assessment Title Appendix A:...

208

Green Island Power Authority Transmission Voltage Support System...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Green Island Power Authority Transmission Voltage Support System Project Green Island Power Authority Transmission Voltage Support System Project Power point presentation...

209

SRAM write-ability improvement with transient negative bit-line voltage  

Science Conference Proceedings (OSTI)

Increasing variations in device parameters significantly degrades the write-ability of SRAM cells in deep sub-100 nm CMOS technology. In this paper, a transient negative bit-line voltage technique is presented to improve write-ability of SRAM cell. Capacitive ... Keywords: SRAM, capacitive coupling, variation, write-ability

Saibal Mukhopadhyay; Rahul M. Rao; Jae-Joon Kim; Ching-Te Chuang

2011-01-01T23:59:59.000Z

210

ENHANCEMENT OF ORGANIC PHOTOVOLTAIC CELL OPEN CIRCUIT ...  

enhancement of organic photovoltaic cell open circuit voltage using electron/hole blocking exciton blocking layers united states patent application

211

A multilevel voltage-source inverter with separate dc sources for static var generation  

SciTech Connect

A new multilevel voltage-source inverter with a separate dc sources is proposed for high-voltage, high-power applications, such as flexible ac transmission systems (FACTS) including static var generation (SVG), power line conditioning, series compensation, phase shifting, voltage balancing, fuel cell and photovoltaic utility systems interfacing, etc. The new M-level inverter consists of (M-1)/2 single phase full bridges in which each bridge has its own separate dc source. This inverter can generate almost sinusoidal waveform voltage with only one time switching per cycle as the number of levels increases. It can solve the problems of conventional transformer-based multipulse inverters and the problems of the multilevel diode-clamped inverter and the multilevel flying capacitor inverter. To demonstrate the superiority of the new inverter, a SVG system using the new inverter topology is discussed through analysis, simulation and experiment.

Peng, Fang Zheng [Tennessee Univ., Knoxville, TN (United States)]|[Oak Ridge National Lab., TN (United States); Lai, Jih-Sheng; McKeever, J.; VanCoevering, J. [Oak Ridge National Lab., TN (United States)

1995-09-01T23:59:59.000Z

212

Intelligent Machine Learning Analysis for Fuel Cell Operations  

SciTech Connect

A performance computational model for a 100 kW nominal solid oxide fuel cell generator system is described. The calculational methods are based on the FORTRAN programming language. Comprehensive parameter input options are presented, and constraints are identified. Example reactant, electrical, and efficiency outputs are demonstrated over the relevant operating ranges. A sample calculated output display at nominal operating conditions is given.

Murphy, R.W.; Hoyt, W.A.

2000-06-30T23:59:59.000Z

213

untitled  

NLE Websites -- All DOE Office Websites (Extended Search)

Battery Specifi cations Manufacturer: Sanyo Electric Co. Battery Type: Nickel Metal Hydride Rated Capacity: 5.5 Ahr Rated Power: NA Nominal Pack Voltage: 330.0 VDC Nominal Cell...

214

untitled  

NLE Websites -- All DOE Office Websites (Extended Search)

Battery Specifi cations Manufacturer: Sanyo Battery Type: Nickel Metal Hydride Rated Capacity: 6.0 Ahr Rated Power: Not Available Nominal Pack Voltage: 144.0 VDC Nominal Cell...

215

untitled  

NLE Websites -- All DOE Office Websites (Extended Search)

Battery Specifi cations Manufacturer: Panasonic Battery Type: Nickel Metal Hydride Rated Capacity: 5.5 Ahr Rated Power: Not Available Nominal Pack Voltage: 158.4 VDC Nominal Cell...

216

Manufacturer: Panasonic Battery Type: ...  

NLE Websites -- All DOE Office Websites (Extended Search)

Battery Specifi cations Manufacturer: Panasonic Battery Type: Nickel Metal Hydride Rated Capacity: 5.5 Ahr Rated Power: Not Available Nominal Pack Voltage: 158.4 VDC Nominal Cell...

217

An Electronic Voltage Transformer Based on WLAN Technology  

Science Conference Proceedings (OSTI)

An electronic voltage transformer based on WLAN technology is developed for adapting to the development trends of substations’ synthesis automation. The transformer is composed of voltage-to-current conversion unit, signal processing unit and data ... Keywords: electronic voltage transformer, voltage-to-current conversion, WLAN technology, digital interface, wireless communication

Jianqin Feng; Qingming Wang; Fen Niu; Guangzhao Cui; Anping Zheng

2010-03-01T23:59:59.000Z

218

Motor voltage high harmonics influence to efficient energy usage  

Science Conference Proceedings (OSTI)

Analysis of the effect of non-sinusoidal voltages on the three-phase induction motor is presented in the paper. When the induction motors are supplied by a rectangular shape of the voltage inverter with high levels of harmonic voltage (Uh,i ... Keywords: energy efficiency, harmonics, induction motor, non-sinusoidal voltage, power losses

Miloje M. Kostic; Branka B. Kostic

2011-07-01T23:59:59.000Z

219

Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics  

DOE Green Energy (OSTI)

This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

Liu, E.; Bebic, J.

2008-02-01T23:59:59.000Z

220

Optimal Compensation Algorithms for a Dynamic Voltage Restorer  

Science Conference Proceedings (OSTI)

The Dynamic Voltage Restorer (DVR) as an electronics based custom device, is used to protect sensitive loads from the voltage sags in the power distribution system. With the rapid technology advancement in industrial control processes, it is experiencing ... Keywords: Dynamic Voltage Restorer (DVR), power quality, voltage sag, Zero Active Power Compensation (ZAPC), Minimal Active Power Compensation (MAPC)

Deng Pan; Chen Zhongming; Jiang Peng; Abdelkrim Benchaib; Guillaume De Preville

2010-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Analysis of Voltage Rise Effect on Distribution Network with Distributed  

E-Print Network (OSTI)

appearance of hidden loads and affect the voltage profile of low voltage distribution network. To overcomeAnalysis of Voltage Rise Effect on Distribution Network with Distributed Generation M. A. Mahmud. This paper presents a detail analysis of how does voltage rise on distribution network due to the penetration

Pota, Himanshu Roy

222

Cascode buffer for monolithic voltage conversion operating at high input supply voltages  

E-Print Network (OSTI)

A high-to-low switching DC-DC converter that operates at input supply voltages up to two times as high as the maximum voltage permitted in a nanometer CMOS technology is proposed in this paper. The circuit technique is based on a cascode bridge that maintains the steady-state voltage differences among the terminals of all of the transistors within a range imposed by a specific fabrication technology. The proposed circuit technique permits the full integration of active and passive devices of a switching DC-DC converter with a high voltage conversion ratio in a standard low voltage CMOS process. An efficiency of 87.8 % is achieved for 3.6 volts to 0.9 volts conversion assuming

Volkan Kursun; Gerhard Schrom; Vivek K. De; Eby G. Friedman; Siva G. Narendra

2005-01-01T23:59:59.000Z

223

Reliability and Lifetime Testing of the DARHT Second Axis Induction Cells  

E-Print Network (OSTI)

pulse duration requirement. The higher voltages were definedrequirement of the cells has also been achieved. Without any scaling for increased voltage,

Waldron, W.L.; Nielsen, K.E.; Spence, P.W.

2005-01-01T23:59:59.000Z

224

Developments in line-voltage thermostats  

Science Conference Proceedings (OSTI)

A thermostat that provides reliable, accurate temperature control is the key to a comfortable, efficient space-heating system. The lack of a commercially available line-voltage thermostat that is affordable and performs well has been a significant factor in limiting the comfort and popularity of zoned residential electric heating systems. With EPRI support, two manufacturers have developed innovative, electronics-based line-voltage thermostats that offer a cost-effective control option for creating a comfortable environment with zoned electric heat. These thermostats also may help reduce energy consumption.

Kesselring, J.

1992-09-01T23:59:59.000Z

225

Group 3: Humidity, Temperature and Voltage (Presentation)  

SciTech Connect

This is a summary of the work of Group 3 of the International PV QA Task Force. Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-09-01T23:59:59.000Z

226

High voltage VLF testing of power cables  

SciTech Connect

This publication describes a laboratory test program conducted with the objective to develop a test that would replace the existing dc withstand test. The article describes the methodology used to establish the voltage duration and magnitude of VLF (0.1 Hz) high voltage field tests suitable for crosslinked polyethylene (XLPE) insulated power cable. The results show that the voltage breakdown of laboratory aged XLPE cable at 0.1 Hz is approximately equal to that at 60 Hz, that proof tests at 0.1 Hz is approximately equal to that at 60 Hz, that proof tests at 0.1 Hz cause very little damage to the cable, and that 0.1 Hz testing appears to be a satisfactory alternate to dc testing. Preliminary values are suggested for voltage magnitude and time duration of cable acceptance, maintenance and proof tests at 0.1 Hz for XLPE cable rated up to 35 kV. A program is underway to similarly evaluate samples of service-aged XLPE cable; as well as to demonstrate the use of the preliminary test values at typical utility installations.

Eager, G.S.; Katz, C.; Fryszczyn, B. [Cable Technology Labs., Inc., New Brunswick, NJ (United States); Densley, J. [Ontario Hydro, Toronto, Ontario (Canada); Bernstein, B.S. [EPRI, Washington, DC (United States)

1997-04-01T23:59:59.000Z

227

System Voltage Potential-Induced Degradation Mechanisms in PV Modules and Methods for Test: Preprint  

DOE Green Energy (OSTI)

Over the past decade, degradation and power loss have been observed in PV modules resulting from the stress exerted by system voltage bias. This is due in part to qualification tests and standards that do not adequately evaluate for the durability of modules to the long-term effects of high voltage bias experienced in fielded arrays. High voltage can lead to module degradation by multiple mechanisms. The extent of the voltage bias degradation is linked to the leakage current or coulombs passed from the silicon active layer through the encapsulant and glass to the grounded module frame, which can be experimentally determined; however, competing processes make the effect non-linear and history-dependent. Appropriate testing methods and stress levels are described that demonstrate module durability to system voltage potential-induced degradation (PID) mechanisms. This information, along with outdoor testing that is in progress, is used to estimate the acceleration factors needed to evaluate the durability of modules to system voltage stress. Na-rich precipitates are observed on the cell surface after stressing the module to induce PID in damp heat with negative bias applied to the active layer.

Hacke, P.; Terwilliger, K.; Smith, R.; Glick, S.; Pankow, J.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-07-01T23:59:59.000Z

228

NOMINATION FOR THE PROJECT MANAGEMENT INSTITUTE (PMI) PROJECT OF THE YEAR AWARD INTEGRATED DISPOSAL FACILITY (IDF)  

Science Conference Proceedings (OSTI)

CH2M HILL Hanford Group, Inc. (CH2M HILL) is pleased to nominate the Integrated Disposal Facility (IDF) project for the Project Management Institute's consideration as 2007 Project of the Year, Built for the U.S, Department of Energy's (DOE) Office of River Protection (ORP) at the Hanford Site, the IDF is the site's first Resource Conservation and Recovery Act (RCRA)-compliant disposal facility. The IDF is important to DOE's waste management strategy for the site. Effective management of the IDF project contributed to the project's success. The project was carefully managed to meet three Tri-Party Agreement (TPA) milestones. The completed facility fully satisfied the needs and expectations of the client, regulators and stakeholders. Ultimately, the project, initially estimated to require 48 months and $33.9 million to build, was completed four months ahead of schedule and $11.1 million under budget. DOE directed construction of the IDF to provide additional capacity for disposing of low-level radioactive and mixed (i.e., radioactive and hazardous) solid waste. The facility needed to comply with federal and Washington State environmental laws and meet TPA milestones. The facility had to accommodate over one million cubic yards of the waste material, including immobilized low-activity waste packages from the Waste Treatment Plant (WTP), low-level and mixed low-level waste from WTP failed melters, and alternative immobilized low-activity waste forms, such as bulk-vitrified waste. CH2M HILL designed and constructed a disposal facility with a redundant system of containment barriers and a sophisticated leak-detection system. Built on a 168-area, the facility's construction met all regulatory requirements. The facility's containment system actually exceeds the state's environmental requirements for a hazardous waste landfill. Effective management of the IDF construction project required working through highly political and legal issues as well as challenges with permitting, scheduling, costs, stakeholders and technical issues. To meet the customer's needs and deadlines, the project was managed with conscientious discipline and application of sound project management principles in the Project Management Institute's Project Management Body of Knowledge. Several factors contributed to project success. Extensive planning and preparation were conducted, which was instrumental to contract and procurement management. Anticipating issues and risks, CH2M HILL prepared well defined scope and expectations, particularly for safety. To ensure worker safety, the project management team incorporated CH2M HILL's Integrated Safety Management System (ISMS) into the project and included safety requirements in contracting documents and baseline planning. The construction contractor DelHur Industries, Inc. adopted CH2M HILL's safety program to meet the procurement requirement for a comparable ISMS safety program. This project management approach contributed to an excellent safety record for a project with heavy equipment in constant motion and 63,555 man-hours worked. The project manager worked closely with ORP and Ecology to keep them involved in project decisions and head off any stakeholder or regulatory concerns. As issues emerged, the project manager addressed them expeditiously to maintain a rigorous schedule. Subcontractors and project contributors were held to contract commitments for performance of the work scope and requirements for quality, budget and schedule. Another element of project success extended to early and continual involvement of all interested in the project scope. Due to the public sensitivity of constructing a landfill planned for radioactive waste as well as offsite waste, there were many stakeholders and it was important to secure their agreement on scope and time frames. The project had multiple participants involved in quality assurance surveillances, audits and inspections, including the construction contractor, CH2M HILL, ORP, the Washington State Department of Ecology, and independent certified quality assurance an

MCLELLAN, G.W.

2007-02-07T23:59:59.000Z

229

The Constant Voltage Transformer (CVT) for Mitigating Effects of Voltage Sags on Industrial Equipment  

E-Print Network (OSTI)

Electric quality problems associated with power interactions between distribution and industrial process control systems can be prevented. Surveys of large users that buy power at the transmission and distribution voltages turn up relatively few complaints about the quality of their incoming power, while surveys of small users connected at secondary voltages tum up numerous complaints about the quality of their incoming power. Three major changes in the characteristics of customer loads and power distribution systems have altered the nature of the power quality equation: (I) greater sensitivity of devices and equipment to electric power variations, (2) the interconnection of sensitive loads in extensive networks and automated processes, and (3) an increase in loads that use power electronics in some type of power conversion configuration [1][2]. This paper presents applications of the constant-voltage transformer (CVT) for mitigating the effects of electric service voltage sags on industrial equipment in an oil refinery. Unlike conventional transformers, the CVT or ferro-resonant transformer allows the core to become saturated with magnetic flux, which maintains a relatively constant output voltage during input voltage variations such as undervoltages, overvoltages, and harmonic distortion.

Ferraro, R. J.; Osborne, R.; Stephens, R.

2000-04-01T23:59:59.000Z

230

• Knowledge Center: The Learning Potential Is Limitless • Formulate and Present Effective Business Cases Honor Members by Nominating Them for Prestigious Awards  

E-Print Network (OSTI)

Help ISACA’s Board of Directors honor individuals who have made a difference in ISACA ® and the professions it supports by nominating an individual for the Harold Weiss or John Lainhart awards.

Read More; Read More; Read More; Read More; John Lainhart

2013-01-01T23:59:59.000Z

231

The Influence of Catalysts on Discharge and Charge Voltages of Rechargeable Li–Oxygen Batteries  

E-Print Network (OSTI)

This study revealed the strong influence of carbon, Au/C, and Pt/C catalysts on the charge and discharge voltages of rechargeable Li–O[subscript 2] batteries. Li–O[subscript 2] single-cell measurements showed that Au/C had ...

Gasteiger, Hubert A.

232

FEM analysis of voltage drop in the anode connector induced by steel stub diameter reduction  

Science Conference Proceedings (OSTI)

Primary aluminium production is a high-energy consumption process, and improving the energy efficiency of smelters could be economically viable. An issue in the Hall-Heroult prebake anode technology is the voltage drop in the anode connector caused by ... Keywords: Aluminium reduction cell, Carbon anode, Energy efficiency, Finite element method, Stub hole, Thermo-electro-mechanical modelling

Hugues Fortin; Nedeltcho Kandev; Mario Fafard

2012-05-01T23:59:59.000Z

233

Electrical system architecture having high voltage bus  

DOE Patents (OSTI)

An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

2011-03-22T23:59:59.000Z

234

Sacramento Area Voltage Support Environmental Impact Statement  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

E E R R A N E V A D A R E G I O N Sacramento Area Voltage Support DRAFT ENVIRONMENTAL IMPACT STATEMENT DRAFT ENVIRONMENTAL IMPACT STATEMENT DOE/EIS-0323 NOVEMBER 2002 COVER SHEET Title: Sacramento Area Voltage Support Draft Environmental Impact Statement (EIS) Lead Agency: Western Area Power Administration (Western) Location: Alameda, Contra Costa, Placer, Sacramento, San Joaquin, and Sutter Counties, State of California. EIS Number: DOE/EIS-0323 Contact: Ms. Loreen McMahon, Environmental Project Manager Western Area Power Administration Sierra Nevada Region 114 Parkshore Drive Folsom, CA 95630 (916) 353-4460 (916) 985-1936 fax email: mcmahon@wapa.gov Website: Information is also available on our website: www.wapa.gov Hotline: 1-877-913-4440 (toll-free) Abstract The Western Area Power Administration's Central Valley Project transmission system forms an integral part of

235

LOW VOLTAGE 14 Mev NEUTRON SOURCE  

DOE Patents (OSTI)

An apparatus yielding high-energy neutrons at the rate of 10/sup 8/ or more per second by the D,T or D,D reactions is described. The deuterium gas filling is ionized by electrons emitted from a filament, and the resulting ions are focused into a beam and accelerated against a fixed target. The apparatus is built in accordance with the relationship V/sub s/ = A--B log pd, where V/sub s/ is the sparking voltage, p the gas pressure, and d the gap length between the high voltage electrodes. Typical parameters to obtain the high neutron yields are 55 to 80 kv, 0.5 to 7.0 ma beam current, 5 to 12 microns D/sub 2/, and a gap length of 1 centimeter.

Little, R.N. Jr.; Graves, E.R.

1959-09-29T23:59:59.000Z

236

Low Swing Dual Threshold Voltage Domino Logic  

E-Print Network (OSTI)

A low swing domino logic technique is proposed to decrease power consumption without sacrificing noise immunity. With the proposed low swing domino logic circuit technique, active power consumption is reduced by up to 9.4% while improving the noise immunity by 2.6% as compared to standard domino logic circuits. It is also shown that by applying a low swing contention reduction technique, the power savings can be further increased by 6.7% while the delay can be improved by 8.6%. A simple and efficient dual threshold voltage (dual-V t ) circuit technique that incorporates low swing signals is also proposed. It is shown that the proposed dual-V technique reduces the standby leakage current by approximately 235 times while offering enhanced delay characteristics as compared to a standard low threshold voltage implementation.

Volkan Kursun; Eby G. Friedman

2002-01-01T23:59:59.000Z

237

HIGH VOLTAGE, HIGH CURRENT SPARK GAP SWITCH  

DOE Patents (OSTI)

A high voltage and current spark gap switch comprising two main electrodes insulatingly supported in opposed spaced relationship and a middle electrode supported medially between the main electrodes and symmetrically about the median line of the main electrodes is described. The middle electrode has a perforation aligned with the median line and an irradiation electrode insulatingly supported in the body of the middle electrode normal to the median line and protruding into the perforation. (AEC)

Dike, R.S.; Lier, D.W.; Schofield, A.E.; Tuck, J.L.

1962-04-17T23:59:59.000Z

238

Low-Voltage Cable Aging Management Guidance  

Science Conference Proceedings (OSTI)

This report, intended for use by power plant engineers and craft and administrative personnel who are responsible for cable system aging management, provides guidance on the effective and efficient application of current information and techniques related to aging and condition monitoring (CM) of low-voltage cables. The identification of cables that are prone to early aging and the timely replacement or repair of cables that are degraded will minimize unnecessary power losses, unplanned shutdowns, ...

2013-12-23T23:59:59.000Z

239

A compact high voltage pulse generator  

SciTech Connect

A compact, easily transportable, pulse generator has been developed for a variety of applications that require a pulse duration in the range of 1 {mu} sec., voltages from 150 to 300 KV and current levels from 2,000 to 3,000 amps. The generator has a simple cylindrical configuration and modular construction to facilitate assembly and service. The generator may be operated single-pulse or repetitively at pulse repetition rates to 50 Hz in a burst mode.

Rohwein, G.J.; Babcock, S.R.

1994-07-01T23:59:59.000Z

240

Electro-optic voltage sensor head  

DOE Patents (OSTI)

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers.

Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Woods, Gregory K. (Cornelius, OR)

1999-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Electro-optic voltage sensor head  

DOE Patents (OSTI)

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers. 6 figs.

Crawford, T.M.; Davidson, J.R.; Woods, G.K.

1999-08-17T23:59:59.000Z

242

Physical design with multiple on-chip voltages  

Science Conference Proceedings (OSTI)

Supply voltage is one of the dominant factors that determine the timing performance and power consumption of VLSI chips. For digital systems with a single supply voltage, some logic devices typically operate faster or more frequently than necessary, ...

Chunhong Chen

2002-04-01T23:59:59.000Z

243

NIST Online Museum of Quantum Voltage Standards, 1990s  

Science Conference Proceedings (OSTI)

... (Artifact 7, Citation: SP Benz, "Superconductor-normal-superconductor junctions for programmable voltage standards," Appl. Phys. Lett., vol. 67, pp. ...

2013-02-28T23:59:59.000Z

244

Activated Sintering, Spark Plasma Sintering and High Voltage ...  

Science Conference Proceedings (OSTI)

Mar 4, 2013 ... Novel Synthesis and Consolidation of Powder Materials : Activated Sintering, Spark Plasma Sintering and High Voltage Electric Discharge ...

245

Temperature Fitting Method Predicting Equidistant Voltage Drop of ...  

Science Conference Proceedings (OSTI)

High Temperature Compression Test to Determine the Anode Paste ... Temperature Fitting Method Predicting Equidistant Voltage Drop of Anode Nod in  ...

246

Development of the Platform-Mounted Dynamic Voltage Restorer (PMDVR)  

Science Conference Proceedings (OSTI)

The uninterrupted supply of electrical power is critical for many commercial utility customers with sensitive loads. A voltage sag of a few cycles could cause loss of many thousands of dollars due to lost production from process stoppage and associated clean-up issues. The Platform Mounted Dynamic Voltage Restorer (PMDVR) is a distribution voltage level device that compensates for changes in supply line voltage to maintain acceptable input power to customers.

1998-12-31T23:59:59.000Z

247

System for increasing corona inception voltage of insulating oils  

DOE Patents (OSTI)

The Corona Inception Voltage of insulating oils is increased by repetitive cycles of prestressing the oil with a voltage greater than the corona inception voltage, and either simultaneously or serially removing byproducts of corona by evacuation and heating the oil. 5 figs.

Rohwein, G.J.

1998-05-19T23:59:59.000Z

248

Research of Dynamic Voltage Restorer Based on Repetitive Control Strategy  

Science Conference Proceedings (OSTI)

This paper introduces a dynamic voltage restorer with independent three-phase structure, which is controlled on repetitive control strategy. Computer simulation of the whole repetitive control system is performed by Matlab/Simulink, and the results show ... Keywords: Dynamic Voltage Restorer, Repetitive Control, Voltage Sag

Tianyu Liu

2012-10-01T23:59:59.000Z

249

Distributed Generation Source Stiffness and Its Impact on Voltage Distortion  

Science Conference Proceedings (OSTI)

Distributed generators with loads that create high harmonics can cause excessive voltage distortion. This report's objective was to evaluate under controlled laboratory conditions voltage distortion resulting from application of nonlinear load for three different types of rotary generators and one inverter-based generator. Test results also were used to verify the analytical model for predicting voltage distortion from nonlinear load application.

2001-11-27T23:59:59.000Z

250

Selective compensation of voltage harmonics in grid-connected microgrids  

E-Print Network (OSTI)

1 Selective compensation of voltage harmonics in grid-connected microgrids Mehdi Savaghebia , Juan is proposed for selective compensation of main voltage harmonics in a grid- connected microgrid. The aim level. Keywords Distributed Generator (DG); microgrid; grid-connected; voltage harmonics compensation. 1

Vasquez, Juan Carlos

251

Secondary Control for Voltage Unbalance Compensation in an Islanded Microgrid  

E-Print Network (OSTI)

Secondary Control for Voltage Unbalance Compensation in an Islanded Microgrid Mehdi Savaghebi1 microgrid. The aim of the proposed control approach is to enhance the voltage quality at the point of common unbalance. Keywords-distributed generation; microgrid; secondary control; voltage unbalance compensation I

Vasquez, Juan Carlos

252

Capacitively coupled RF voltage probe having optimized flux linkage  

DOE Patents (OSTI)

An RF sensor having a novel current sensing probe and a voltage sensing probe to measure voltage and current. The current sensor is disposed in a transmission line to link all of the flux generated by the flowing current in order to obtain an accurate measurement. The voltage sensor is a flat plate which operates as a capacitive plate to sense voltage on a center conductor of the transmission line, in which the measured voltage is obtained across a resistance leg of a R-C differentiator circuit formed by the characteristic impedance of a connecting transmission line and a capacitance of the plate, which is positioned proximal to the center conductor.

Moore, James A. (Powell, TN); Sparks, Dennis O. (Maryville, TN)

1999-02-02T23:59:59.000Z

253

Low voltage operation of plasma focus  

SciTech Connect

Plasma foci of compact sizes and operating with low energies (from tens of joules to few hundred joules) have found application in recent years and have attracted plasma-physics scientists and engineers for research in this direction. We are presenting a low energy and miniature plasma focus which operates from a capacitor bank of 8.4 {mu}F capacity, charged at 4.2-4.3 kV and delivering approximately 52 kA peak current at approximately 60 nH calculated circuit inductance. The total circuit inductance includes the plasma focus inductance. The reported plasma focus operates at the lowest voltage among all reported plasma foci so far. Moreover the cost of capacitor bank used for plasma focus is nearly 20 U.S. dollars making it very cheap. At low voltage operation of plasma focus, the initial breakdown mechanism becomes important for operation of plasma focus. The quartz glass tube is used as insulator and breakdown initiation is done on its surface. The total energy of the plasma focus is approximately 75 J. The plasma focus system is made compact and the switching of capacitor bank energy is done by manual operating switch. The focus is operated with hydrogen and deuterium filled at 1-2 mbar.

Shukla, Rohit; Sharma, S. K.; Banerjee, P.; Das, R.; Deb, P.; Prabahar, T.; Das, B. K.; Adhikary, B.; Shyam, A. [Energetics and Electromagnetics Division, Facility for Electromagnetic Systems, Bhabha Atomic Research Center, Visakhapatanam, A.P. 530012 (India)

2010-08-15T23:59:59.000Z

254

High Voltage GaN Schottky Rectifiers  

SciTech Connect

Mesa and planar GaN Schottky diode rectifiers with reverse breakdown voltages (V{sub RB}) up to 550V and >2000V, respectively, have been fabricated. The on-state resistance, R{sub ON}, was 6m{Omega}{center_dot} cm{sup 2} and 0.8{Omega}cm{sup 2}, respectively, producing figure-of-merit values for (V{sub RB}){sup 2}/R{sub ON} in the range 5-48 MW{center_dot}cm{sup -2}. At low biases the reverse leakage current was proportional to the size of the rectifying contact perimeter, while at high biases the current was proportional to the area of this contact. These results suggest that at low reverse biases, the leakage is dominated by the surface component, while at higher biases the bulk component dominates. On-state voltages were 3.5V for the 550V diodes and {ge}15 for the 2kV diodes. Reverse recovery times were <0.2{micro}sec for devices switched from a forward current density of {approx}500A{center_dot}cm{sup -2} to a reverse bias of 100V.

CAO,X.A.; CHO,H.; CHU,S.N.G.; CHUO,C.-C.; CHYI,J.-I.; DANG,G.T.; HAN,JUNG; LEE,C.-M.; PEARTON,S.J.; REN,F.; WILSON,R.G.; ZHANG,A.P.

1999-10-25T23:59:59.000Z

255

System and method for charging electrochemical cells in series  

DOE Patents (OSTI)

A battery charging system capable of equalizing the charge of each individual cell at a selected full charge voltage includes means for regulating charger current to first increase current at a constant rate until a bulk charging level is achieved or until any cell reaches a safe reference voltage. A system controller then begins to decrease the charging rate as long as any cell exceeds the reference voltage until an equalization current level is reached. At this point, the system controller activates a plurality of shunt modules to permit shunting of current around any cell having a voltage exceeding the reference voltage. Leads extending between the battery of cells and shunt modules are time shared to permit alternate shunting of current and voltage monitoring without the voltage drop caused by the shunt current. After each cell has at one time exceeded the reference voltage, the charging current is terminated.

DeLuca, William H. (Naperville, IL); Hornstra, Jr, Fred (St. Charles, IL); Gelb, George H. (Rancho Palos Verdes, CA); Berman, Baruch (Rancho Palos Verdes, CA); Moede, Larry W. (Manhattan Beach, CA)

1980-01-01T23:59:59.000Z

256

Limitation of the Open-Circuit Voltage Due to Metastable Intrinsic Defects in Cu(In,Ga)Se2 and Strategies to Avoid These Defects: Preprint  

DOE Green Energy (OSTI)

This paper summarizes using first-principles defect theory to investigate the role of intrinsic point defects in the limitation of the open-circuit voltage (VOC) in Cu(In,Ga)Se2 solar cells.

Lany, S.; Zunger, A.

2008-05-01T23:59:59.000Z

257

Minimum Energy Compensation Strategy and Characteristic Analysis for Dynamic Voltage Restorer  

Science Conference Proceedings (OSTI)

The minimum energy compensation strategy and its characteristic for Dynamic Voltage Restorer (DVR) considering the equipment’s voltage limitation are discussed. The strategy when the injection voltage is under or especially above the voltage limitation ... Keywords: dynamic voltage restorer, minimum energy compensation, compensation strategy, compensation characteristic, voltage limitation

Yingying Liu; Xu Yonghai; Xiao Xiangning; Guo Chunlin

2009-10-01T23:59:59.000Z

258

Research on the SPLL based single phase voltage sag detection technique  

Science Conference Proceedings (OSTI)

The drop of voltage amplitude and the jump of phase angle are two important parameters of the voltage sag. The design of Dynamic Voltage Restorer (DVR) compensation voltage with voltage sag parameters is discussed and a single-phase sag parameter detection ... Keywords: SPLL, detection, single-phase, voltage sag

Xie Yue; Chen Le; Sun Jian; Gong Xu

2008-04-01T23:59:59.000Z

259

Planar LTCC transformers for high voltage flyback converters.  

SciTech Connect

This paper discusses the design and use of low-temperature (850 C to 950 C) co-fired ceramic (LTCC) planar magnetic flyback transformers for applications that require conversion of a low voltage to high voltage (> 100V) with significant volumetric constraints. Measured performance and modeling results for multiple designs showed that the LTCC flyback transformer design and construction imposes serious limitations on the achievable coupling and significantly impacts the transformer performance and output voltage. This paper discusses the impact of various design factors that can provide improved performance by increasing transformer coupling and output voltage. The experiments performed on prototype units demonstrated LTCC transformer designs capable of greater than 2 kV output. Finally, the work investigated the effect of the LTCC microstructure on transformer insulation. Although this paper focuses on generating voltages in the kV range, the experimental characterization and discussion presented in this work applies to designs requiring lower voltage.

Schofield, Daryl (NASCENT Technology Inc. , Watertown, SD); Schare, Joshua M.; Glass, Sarah Jill; Roesler, Alexander William; Ewsuk, Kevin Gregory; Slama, George (NASCENT Technology Inc. , Watertown, SD); Abel, Dave (NASCENT Technology Inc. , Watertown, SD)

2007-06-01T23:59:59.000Z

260

Sequential circuit design for radiation hardened multiple voltage integrated circuits  

DOE Patents (OSTI)

The present invention includes a radiation hardened sequential circuit, such as a bistable circuit, flip-flop or other suitable design that presents substantial immunity to ionizing radiation while simultaneously maintaining a low operating voltage. In one embodiment, the circuit includes a plurality of logic elements that operate on relatively low voltage, and a master and slave latches each having storage elements that operate on a relatively high voltage.

Clark, Lawrence T. (Phoenix, AZ); McIver, III, John K. (Albuquerque, NM)

2009-11-24T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Waveform Characteristics of Voltage Sags: Definition and Algorithm Development  

Science Conference Proceedings (OSTI)

Voltage disturbances lasting more than one cycle are normally characterized in terms of voltage magnitude and event duration. These parameters provide an easily understood means of characterizing these types of voltage disturbances. However, magnitude and duration are not the only characteristics that affect loads. Many types of loads, such as contactors, control systems, and ac/dc drives, are also affected by other factors, such as the waveshape, the point in the waveform at which the disturbance begins...

1999-08-05T23:59:59.000Z

262

Triple voltage dc-to-dc converter and method  

DOE Patents (OSTI)

A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

Su, Gui-Jia (Knoxville, TN)

2008-08-05T23:59:59.000Z

263

High Voltage Electric Discharge Consolidation of Tantalum Powders  

Science Conference Proceedings (OSTI)

Abstract Scope, The high voltage electric discharge consolidation (HVEDC) is a promising method of the volumetric-porous body manufacturing, which can be ...

264

The Current-voltage Characteristics of Grain Boundaries in Ionic ...  

Science Conference Proceedings (OSTI)

Presentation Title, The Current-voltage Characteristics of Grain Boundaries in Ionic ... A High-temperature Mössbauer Study of Iron-doped Ruddlesden-popper  ...

265

(SPS) and High Voltage Electric Discharge Consolidation (HVEDC  

Science Conference Proceedings (OSTI)

Presentation Title, Inter-Particle Contact Phenomena in Spark-Plasma Sintering ( SPS) and High Voltage Electric Discharge Consolidation (HVEDC). Author(s) ...

266

Spark-plasma Sintering vs. High Voltage Electric Discharge ...  

Science Conference Proceedings (OSTI)

High voltage electric discharge consolidation (HVEDC) includes high axial pressure and discharge of the electrical energy stored in capacitors, thus enabling a ...

267

Voltage Controlled Creep of a Nanoporous Gold/Electrolyte Hybrid ...  

Science Conference Proceedings (OSTI)

And the creep rate can also be controlled by the voltage (electrochemical ... CNT Reinforced Copper Composite for High Contact Pressure Electrodes by ...

268

(SPS) and High Voltage Electric Discharge Consolidation (HVEDC)  

Science Conference Proceedings (OSTI)

Presentation Title, Local Heat Balance in Spark-plasma Sintering (SPS) and High Voltage Electric Discharge Consolidation (HVEDC). Author(s), Eugene ...

269

Road to AC Voltage Standard Leads to Important Junction  

Science Conference Proceedings (OSTI)

Road to AC Voltage Standard Leads to Important Junction. ... Grumman in the mid-1990s.*** A number of innovations since then have led to the first ...

2013-08-13T23:59:59.000Z

270

Chronic Benzodiazepine Administration Potentiates High Voltage-Activated Calcium Currents  

E-Print Network (OSTI)

.aspetjournals.orgDownloadedfrom #12;other drugs of abuse has been reported to enhance high voltage-activated calcium channels (HVAs

Brand, Paul H.

271

fault diagnosis of a high voltage transmission line using waveform ...  

E-Print Network (OSTI)

Oct 4, 2013 ... FAULT DIAGNOSIS OF A HIGH VOLTAGE TRANSMISSION LINE USING ... Fault types such as single line to ground, line to line, double line to ...

272

Multi-winding Homopolar Electric Machine Offers Variable Voltage ...  

Wind Energy Industrial Technologies Multi-winding Homopolar Electric Machine Offers Variable Voltage at Low Rotational Speed Oak Ridge National Laboratory. Contact ...

273

Energy-Big voltage, little package... | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

News DOE Pulse Media Contacts Media Mentions RSS Feeds News Home | ORNL | News | Story Tips SHARE Energy-Big voltage, little package Oak Ridge National Laboratory's new Stinger...

274

A Step Towards Energy-Efficient Voltage Control of Magnetic ...  

Science Conference Proceedings (OSTI)

... By combining these two types of materials, it is possible to create low ... by electric fields (applied voltage) instead of less energy-efficient magnetic ...

2013-07-30T23:59:59.000Z

275

Medium Voltage Cable Aging Management Guide, Revision 1  

Science Conference Proceedings (OSTI)

Medium-voltage cables (5- to 35-kV rated cables) have provided reasonable service in nuclear power plants. However, there is a concern that cables that have experienced long periods of wet service might degrade and fail in service. Because most plants have had few problems with medium-voltage cable, little on-staff experience with medium-voltage cables exists at most sites. This report has been prepared to provide information that will be of practical use when questions concerning medium-voltage cable lo...

2010-11-29T23:59:59.000Z

276

Operating standby redundant controller to improve voltage source inverter reliability .  

E-Print Network (OSTI)

??This thesis presents a control architecture that achieves operating standby redundancy for a voltage source inverter controller. The system was designed to increase reliability by… (more)

Blevins, Stephen T.

2007-01-01T23:59:59.000Z

277

California ISO Real-Time Voltage Security Assessment (VSA) Project...  

NLE Websites -- All DOE Office Websites (Extended Search)

Arnold Schwarzenegger Governor REAL-TIME GRID RELIABILITY MANAGEMENT California ISO Real-Time Voltage Security Assessment (VSA) Project: Summary of Survey Results on Methodologies...

278

Patents and Perspective on Surge Protection for Low-Voltage ...  

Science Conference Proceedings (OSTI)

... In a high-voitage inverter the impedance is a resistor functioning to dampen voltage o\\ershoots and to im- plement a relay or solid state second ...

2013-05-17T23:59:59.000Z

279

Surge Protection in Low-Voltage AC Power Circuits  

Science Conference Proceedings (OSTI)

Surge Protection in Low-Voltage AC Power Circuits: An 8-part Anthology ... converting old and yellowing papers into 21st Century electronic files, and ...

2013-05-20T23:59:59.000Z

280

Voltage Unbalance: Power Quality Issues, Related Standards and Mitigation Techniques: Effect of Unbalanced Voltage on End Use Equipm ent Performance  

Science Conference Proceedings (OSTI)

Unbalanced voltages can result in adverse effects on equipment and the electric distribution system. Under unbalanced conditions the distribution system will incur more losses and heating effects, and be less stable. The effect of voltage unbalance can also be detrimental to equipment such as induction motors, power electronic converters, and adjustable speed drives (ASDs). The purpose of this study is to investigate the causes and effects of voltage unbalance as well as the related standards and mitigat...

2000-06-21T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Local Dynamic Reactive Power for Correction of System Voltage Problems  

SciTech Connect

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

Kueck, John D [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Xu, Yan [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Adhikari, Sarina [ORNL; Irminger, Philip [ORNL

2008-12-01T23:59:59.000Z

282

Design of programmable, low power, low dropout voltage regulators for portable applications  

E-Print Network (OSTI)

As portable electronics constantly find their way into the hands of eager consumers, the demands placed on these products and their circuits are ever increasing. More features and more performance are continuously demanded by consumers. This feature-driven market has brought with it several constraints on the type of circuits utilized in developing these portable devices. Cell-Phones, PDA's, MP3 players and various other portable electronics require different voltage levels to power different architectures that realize the many features within the device. This work demonstrates a technique to design Programmable Low Power Low Dropout Voltage Regulators (LDO). The LDO proposed in this research utilizes a fast-transient feedback loop in order to improve transient response and guarantee stability in all the programmable output levels. Specifically, the main parameters to be improved are stability over the entire load current range, reduced overshoot and undershoot variations in transient response, reduction of LDO deflection voltage, minimization of standby current and low voltage (Vin = 1.2V) operation.

Islas Ohlmaier, Abraham

2005-12-01T23:59:59.000Z

283

Low-voltage electroporation with fluidic microelectrodes  

Science Conference Proceedings (OSTI)

Electroporation is a widely used method for increasing the permeability of the cellular membrane. Impermeant exogenous substances (e.g., DNA, proteins, peptides, dyes) can thus be introduced into the cells. In this study, we have developed an electroporation ... Keywords: Cell electroporation, Fluidic electrodes, Hydrodynamic focusing

Isabella Guido; Chunyang Xiong; Jing Fang

2012-10-01T23:59:59.000Z

284

Robust Design of Basic Low Voltage CMOS Transconductors  

Science Conference Proceedings (OSTI)

Two new low voltage transconductors are introduced and the statistical design of these transconductors are presented. The circuits operate in the saturation region with fully balanced input signals. Initial circuit simulation results are given. Response surface ... Keywords: design of experiments, low voltage, response surface methodology, roboust design, yield enhancement

Tuna B. Tarim; H. Hakan Kuntman; Mohammed Ismail

1999-09-01T23:59:59.000Z

285

Analysis of Voltage Notching Concerns at a Petroleum Pumping Station  

Science Conference Proceedings (OSTI)

This report presents the results of a voltage notching investigation at a petroleum pumping station. The analysis in this paper focuses on a particular example system where the voltage notching caused significant oscillations at the distribution system level, resulting in equipment problems at another customer supplied from the same system.

2003-12-31T23:59:59.000Z

286

Compile-time dynamic voltage scaling settings: opportunities and limits  

Science Conference Proceedings (OSTI)

With power-related concerns becoming dominant aspects of hardware and software design, significant research effort has been devoted towards system power minimization. Among run-time power-management techniques, dynamic voltage scaling (DVS) has emerged ... Keywords: analytical model, compiler, dynamic voltage scaling, low power, mixed-integer linear programming

Fen Xie; Margaret Martonosi; Sharad Malik

2003-06-01T23:59:59.000Z

287

Real-time static voltage scaling on multiprocessors  

Science Conference Proceedings (OSTI)

We propose a real-time static voltage scaling (RT-SVS) technique called T-L plane transforming, which is an extension of LLREF, an optimal real-time scheduling algorithm for multiprocessor systems. We present two RT-SVS algorithms for different types ... Keywords: energy consumption, multiprocessor systems, real-time scheduling, real-time voltage scaling

Kenji Funaoka; Shinpei Kato; Nobuyuki Yamasaki

2007-11-01T23:59:59.000Z

288

Proceedings: EPRI/NERC Forum on Voltage Stability  

Science Conference Proceedings (OSTI)

As power systems are operated at increased stress, utilities are becoming more concerned about voltage collapse and consequent severe disruptions. This meeting, cosponsored by EPRI and NERC, provided a forum for a group of international experts to exchange information on voltage stability, including its physical understanding, operational practices, and application of available tools.

1993-06-01T23:59:59.000Z

289

Wind Farm Grid Voltage Stability Researching Based on Cascade STATCOM  

Science Conference Proceedings (OSTI)

Though most wind turbine use induction generator, when wind induction generator with power generation, it will produce a series of power quality problems such as voltage fluctuations. This paper discusses the mathematical model of the wind induction ... Keywords: Wind induction generator, Cascade STATCOM, Wind farm, Voltage stability

Li Shengqing, Xu Wenxiang, Li Weizhou, Zeng Huanyue

2013-01-01T23:59:59.000Z

290

Nominating Professor Form  

Science Conference Proceedings (OSTI)

Awards Program Mail Address: AOCS, P.O. Box 17190, Urbana, IL 61803-7190 USA Phone: +1 217-693-4804; Fax: +1 217-693-4849 Email: awards@aocs.org; Web: www.aocs.org/awards Student Name: ????? I have known the stud

291

2011 Nominating Professor Form  

Science Conference Proceedings (OSTI)

Awards Program Mail Address: AOCS, P.O. Box 17190, Urbana, IL 61803-7190 USA Phone: +1 217-693-4804; Fax: +1 217-693-4849 EMail: awards@aocs.org; Web: www.aocs.org/goto/awards Student Name: ????? I have known the

292

Award Nomination Form  

Science Conference Proceedings (OSTI)

DOCUMENTS TO: Awards & Recognition Specialist awards@tms.org. If you have any questions,. Contact Deborah Price at: Telephone (724) 776-9000 ext. 232.

293

SSRLUO EC Ballot Nominations  

NLE Websites -- All DOE Office Websites (Extended Search)

place via the web; newly elected members will be announced during the users meeting banquet on October 18th . Program | Workshops | Abstracts | Lytle Award | Vendor Exhibit |...

294

3. nominating committee bylaws  

Science Conference Proceedings (OSTI)

making a final determination. To respect the privacy of unsuccessful nominees for Board positions, a separate report will be prepared and maintained in ...

295

nvitation to Nominate  

The Lawrence Award was established in 1959 by the Atomic Energy Commission and President ... associate professor and in 1930, at the age of 29, he became

296

Nominalizations and aspect  

E-Print Network (OSTI)

Languages that have aspectually-conditioned ergativity splits generally oppose a "perfect" tense (often called perfective or aorist), with ergative-absolutive case pattern, to an imperfective where case marking follows the ...

Salanova, Andrés Pablo

2007-01-01T23:59:59.000Z

297

Reactive Power Management to Address Short-Term Voltage Stability Using Optimal Reactive Power Allocation Method  

Science Conference Proceedings (OSTI)

Voltage stability has attracted attention recently because power systems are increasingly operated under heavy loads and subjected to high levels of dynamic fast acting loads. Voltage instability under these conditions can be manifested as depressed voltage profiles, delayed voltage recovery at load buses following a major disturbance, and even fast voltage collapse. Single-phase, low-inertia induction motors can have adverse effect on voltage stability as they decelerate in the event of voltage ...

2012-11-28T23:59:59.000Z

298

Definition: Automated Voltage And Var Control | Open Energy Information  

Open Energy Info (EERE)

Voltage And Var Control Voltage And Var Control Jump to: navigation, search Dictionary.png Automated Voltage And Var Control Automated voltage and VAR control requires coordinated operation of reactive power resources such as capacitor banks, voltage regulators, transformer load-tap changers, and distributed generation (DG) with sensors, controls, and communications systems. These devices could operate autonomously in response to local events or in response to signals from a central control system.[1] View on Wikipedia Wikipedia Definition Also Known As Volt-VAR Control (VVC) Related Terms smart grid, Reactive Power References ↑ SmartGrid.gov 'Description of Functions' An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from

299

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1996-01-01T23:59:59.000Z

300

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

Shimer, D.W.; Lange, A.C.

1996-10-15T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Living and Working Safely Around High-Voltage Power Lines.  

Science Conference Proceedings (OSTI)

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

United States. Bonneville Power Administration.

2001-06-01T23:59:59.000Z

302

Novel Nonflammable Electrolytes for Secondary Magnesium Batteries and High Voltage Electrolytes for Electrochemcial Supercapacitors  

Science Conference Proceedings (OSTI)

Magnesium has been used successfully in primary batteries, but its use in rechargeable cells has been stymied by the lack of suitable non-aqueous electrolyte that can conduct Mg+2 species, combined with poor stripping and plating properties. The development of a suitable cathode material for rechargeable magnesium batteries has also been a roadblock, but a nonflammable electrolyte is key. Likewise, the development of safe high voltage electrochemical supercapaitors has been stymied by the use of flammable solvents in the liquid electrolyte; to wit, acetonitrile. The purpose of the research conducted in this effort was to identify useful compositions of magnesium salts and polyphosphate solvents that would enable magnesium ions to be cycled within a secondary battery design. The polyphosphate solvents would provide the solvent for the magnesium salts while preventing the electrolyte from being flammable. This would enable these novel electrolytes to be considered as an alternative to THF-based electrolytes. In addition, we explored several of these solvents together with lithium slats for use as high voltage electrolytes for carbon-based electrochemical supercapacitors. The research was successful in that: 1) Magnesium imide dissolved in a phosphate ester solvent that contains a halogented phosphate ester appears to be the preferred electrolyte for a rechargeable Mg cell. 2) A combination of B-doped CNTs and vanadium phosphate appear to be the cathode of choice for a rechargeable Mg cell by virtue of higher voltage and better reversibility. 3) Magnesium alloys appear to perform better than pure magnesium when used in combination with the novel polyphosphate electrolytes. Also, this effort has established that Phoenix Innovationâ??s family of phosphonate/phosphate electrolytes together with specific lithium slats can be used in supercapacitor systems at voltages of greater than 10V.

Dr. Brian Dixon

2008-12-30T23:59:59.000Z

303

Electrical Modeling of Polymer Solar Cell  

Science Conference Proceedings (OSTI)

A numerical model to predict the current-voltage curves of bilayer polymer solar cell. The model includes drift and diffusion currents, injection and extraction at ...

304

Improving the low voltage ride through of doubly fed induction generator during intermittent voltage source converter faults  

E-Print Network (OSTI)

on the low voltage ride through (LVRT) capability of the doubly fed induction generator (DFIG) is also) controller to mitigate the effects of these faults is proposed. The DFIG compliance with numerous and compared. Simulation results indicate that these types of faults have a severe impact on the DFIG voltage

Pota, Himanshu Roy

305

High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1995-01-01T23:59:59.000Z

306

High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

Shimer, D.W.; Lange, A.C.

1995-05-23T23:59:59.000Z

307

Using Radial Basis Functions to Approximate Battery Differential Capacity and Differential Voltage  

Science Conference Proceedings (OSTI)

As part of the Department of Energy’s Applied Battery Research Program, lithium-ion cells of various sizes and chemistries are aged with periodic reference performance tests to ascertain degradation rates. The reference tests included a very slow discharge and charge based on a constant current equal to 1/25th of the rated capacity to elucidate the true electrochemical capacity of the cell. A differential analysis of these data helps to identify the individual kinetic and thermodynamic contributions of the anode and cathode. However, differential curves are very noisy, and previous smoothing methods included simple data reduction and moving averages. This paper introduces an alternative method of finding the differential voltage and differential capacity curves based on radial basis functions. The voltage profile is fit with a number of Gaussian curves, and the resulting model is differentiated. This approach also has the added advantage of assessing model uncertainty based on a bootstrap analysis. The radial basis function method was successfully applied to various lithium-ion chemistries tested under the Applied Battery Research Program. The resulting differential capacity and differential voltage curves were generally smoother than the corresponding curves found by previous methods and also showed little variance, indicating a good model fit. These results imply that the radial basis function technique is a more robust tool for assessing differential data.

Jon P. Christophersen; Steven R. Shaw

2010-02-01T23:59:59.000Z

308

A Survey on the Principle and Control of Dynamic Voltage Restorer  

Science Conference Proceedings (OSTI)

With the development of information and automation techniques, dynamic voltage problems are once again in the spotlight. Dynamic voltage restorer (DVR) is a modern and important custom power device used for mitigating voltage sags in power distribution ... Keywords: voltage sag, dynamic voltage restorer (DVR), control strategy, power quality, optimized compensation, energy storage

Shuhong Kong; Zhongdong Yin; Renzhong Shan; Weidong Shang

2009-10-01T23:59:59.000Z

309

Low-voltage-swing Monolithic DC-DC Conversion  

E-Print Network (OSTI)

Abstract—A low-voltage-swing MOSFET gate drive technique is proposed in this paper for enhancing the efficiency characteristics of high-frequency-switching dc–dc converters. The parasitic power dissipation of a dc–dc converter is reduced by lowering the voltage swing of the power transistor gate drivers. A comprehensive circuit model of the parasitic impedances of a monolithic buck converter is presented. Closed-form expressions for the total power dissipation of a low-swing buck converter are proposed. The effect of reducing the MOSFET gate voltage swings is explored with the proposed circuit model. A range of design parameters is evaluated, permitting the development of a design space for full integration of active and passive devices of a low-swing buck converter on the same die, for a target CMOS technology. The optimum gate voltage swing of a power MOSFET that maximizes efficiency is lower than a standard full voltage swing. An efficiency of 88 % at a switching frequency of 102 MHz is achieved for a voltage conversion from 1.8 to 0.9 V with a low-swing dc–dc converter based on a 0.18- m CMOS technology. The power dissipation of a low-swing dc–dc converter is reduced by 27.9 % as compared to a standard full-swing dc–dc converter. Index Terms—Buck converter, dc–dc converters, enhanced efficiency, high frequency, low power, low swing, monolithic integration, on-chip voltage conversion, parameter optimization, parasitic impedances, power dissipation modeling, power supply, reduced energy dissipation, reduced voltage swing, switching voltage regulator. I.

Volkan Kursun; Siva G. Narendra; Vivek K. De; Eby G. Friedman

2004-01-01T23:59:59.000Z

310

Optically triggered high voltage switch network and method for switching a high voltage  

DOE Patents (OSTI)

An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

1993-01-19T23:59:59.000Z

311

Fault Detection and Isolation in Low-Voltage DC Distribution ...  

A University of Colorado research team led by Jae-Do Park has developed a fault detection and isolation scheme for a low-voltage DC-bus microgrid system, ...

312

NIST Online Museum of Quantum Voltage Standards, 1970s  

Science Conference Proceedings (OSTI)

... Metrologists wondered if they could connect several junctions in series to make a larger voltage, just as a 12-volt car battery is made up of six 2-volt ...

2011-03-30T23:59:59.000Z

313

Fusing strategies for the dual-voltage fault  

E-Print Network (OSTI)

This thesis focuses on the 42V - 14V fault in a dual voltage system and discusses the possibility of effective fusing. A simple model for the system had been created from technical documentation. Based on the model and the ...

Shrivastava, Rupam, 1981-

2005-01-01T23:59:59.000Z

314

Functionalized High Voltage Spinel Composite for High Power ...  

Science Conference Proceedings (OSTI)

Recently, spinel LiNi0.5Mn1.5O4 with high working voltage and long cycle life makes it become the one of most promising cathode for high power delivery.

315

ESS 2012 Peer Review - Low Cost, Manufacturable High Voltage...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Storage for Power Flow Management and Voltage Control on an 11kV UK Distribution Network", 20th International Conference on Electricity Distribution, June 2009. S1 S2 C1 C2...

316

Robust Design of Basic Low Voltage CMOS Transconductors  

Science Conference Proceedings (OSTI)

Two new low voltage transconductors are introduced and the statistical design of these transconductors are presented. The circuits operate in the saturation region with fully balanced input signals. Initial circuit simulation results are given. Response surface ...

Tuna B. Tarim; H. Hakan Kuntman; Mohammed Ismail

1999-09-01T23:59:59.000Z

317

High-voltage air-core pulse transformers  

SciTech Connect

General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

Rohwein, G. J.

1981-01-01T23:59:59.000Z

318

Quartz crystal microbalance based on passive frequency to voltage converter  

SciTech Connect

In dynamics of evaporation or drying of microdrops from a solid surface, a faster and precise quartz crystal microbalance (QCM) is needed. The fast QCM based on frequency to voltage converter is an attractive and powerful tool in the investigation of the dynamic regime of evaporation to translate the frequency shift in terms of a continuous voltage change. The frequency shift monitoring in fast QCM applications is a real challenge for electronic processing interface. Originally developed as a frequency shift processing interface, this novel passive frequency to voltage converter can produce faster, stable, and accurate results in regard to the QCM sensor behavior. In this article, the concept and circuit of passive frequency to voltage converter will be explained followed by static and dynamic characterization. Experimental results of microdrops evaporation will be given.

Burda, Ioan; Tunyagi, Arthur [Department of Physics, Babes-Bolyai University, Cluj-Napoca, 400084 (Romania)

2012-02-15T23:59:59.000Z

319

Planar LTCC transformers for high voltage flyback converters: Part II.  

Science Conference Proceedings (OSTI)

This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

Schofield, Daryl (NASCENTechnology, Inc., Watertown, SD); Schare, Joshua M., Ph.D.; Slama, George (NASCENTechnology, Inc., Watertown, SD); Abel, David (NASCENTechnology, Inc., Watertown, SD)

2009-02-01T23:59:59.000Z

320

Time varying voltage combustion control and diagnostics sensor  

DOE Patents (OSTI)

A time-varying voltage is applied to an electrode, or a pair of electrodes, of a sensor installed in a fuel nozzle disposed adjacent the combustion zone of a continuous combustion system, such as of the gas turbine engine type. The time-varying voltage induces a time-varying current in the flame which is measured and used to determine flame capacitance using AC electrical circuit analysis. Flame capacitance is used to accurately determine the position of the flame from the sensor and the fuel/air ratio. The fuel and/or air flow rate (s) is/are then adjusted to provide reduced flame instability problems such as flashback, combustion dynamics and lean blowout, as well as reduced emissions. The time-varying voltage may be an alternating voltage and the time-varying current may be an alternating current.

Chorpening, Benjamin T. (Morgantown, WV); Thornton, Jimmy D. (Morgantown, WV); Huckaby, E. David (Morgantown, WV); Fincham, William (Fairmont, WV)

2011-04-19T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Light Flicker in Compact Fluorescent Lamps Caused by Voltage Fluctuations  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the EPRI Power Electronics Applications Center (PEAC) Power Quality Test Facility to characterize the light output of an incandescent lamp and compact fluorescent lamps during voltage fluctuations.

2003-12-31T23:59:59.000Z

322

Elevated Neutral to Earth and Contact Voltages in Distribution Systems  

Science Conference Proceedings (OSTI)

Perceptible voltage potentials at publicly and privately accessible human and animal contact locations pose concerns for utilities, regulators, and the public. Each year since 2004, EPRI research in this area has considered the most important concerns associated with these perceptible voltages by promoting consistent and repeatable assessment methodologies, sponsoring workshops, and creating a repository of case studies and general information. These and other project efforts are geared toward expediting...

2008-12-18T23:59:59.000Z

323

INTENSITY OF BETATRON RADIATION AS FUNCTION OF INJECTION VOLTAGE  

SciTech Connect

The intensity of betatron radiation emission as a function of injection voltage was studied using a 25-Mev betatron with a 350-kw external electron injector. The injection voltage was measured every 20 to 30 kw from 50 to 250 kw. The results showed that up to 250 kw, emission intensity increases according to theory. It is suggested that an increase in injection intensity up to 1000 kw and over should result in a considerable rise in emission intensity. (R.V.J.)

Moskalev, V.A.; Okulov, B.V.

1962-09-01T23:59:59.000Z

324

Cable Aging Management Training Course for Low-Voltage Cables  

Science Conference Proceedings (OSTI)

The "EPRI PSE Cable Aging Training Course for Low-Voltage Cables" provides a basis for understanding of the aging of the insulation and jackets of electrical cables used in low-voltage systems. Practical techniques for determining which cables are prone to premature aging and for evaluating their condition are described. The course contains 11 modules. The first 9 modules describe the body of the cable aging management process. The last two modules, "Cable Failure Assessment" and "Performing a Walkdown o...

2003-11-24T23:59:59.000Z

325

Optical control system for high-voltage terminals  

DOE Patents (OSTI)

An optical control system for the control of devices in the terminal of an electrostatic accelerator includes a laser that is modulated by a series of preselected codes produced by an encoder. A photodiode receiver is placed in the laser beam at the high-voltage terminal of an electrostatic accelerator. A decoder connected to the photodiode decodes the signals to provide control impulses for a plurality of devices at the high voltage of the terminal.

Bicek, John J. (Tinley Park, IL)

1978-01-01T23:59:59.000Z

326

Measuring Helical FCG Voltage with an Electric Field Antenna  

SciTech Connect

A method of measuring the voltage produced by a helical explosive flux compression generator using a remote electric field antenna is described in detail. The diagnostic has been successfully implemented on several experiments. Measured data from the diagnostic compare favorably with voltages predicted using the code CAGEN, validating our predictive modeling tools. The measured data is important to understanding generator performance, and is measured with a low-risk, minimally intrusive approach.

White, A D; Anderson, R A; Javedani, J B; Reisman, D B; Goerz, D A; Ferriera, A J; Speer, R D

2011-08-01T23:59:59.000Z

327

High voltage electrical amplifier having a short rise time  

DOE Patents (OSTI)

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and the voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage. 8 figs.

Christie, D.J.; Dallum, G.E.

1989-12-07T23:59:59.000Z

328

High voltage electrical amplifier having a short rise time  

DOE Patents (OSTI)

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

1991-01-01T23:59:59.000Z

329

Pattern recognition monitoring of PEM fuel cell  

DOE Patents (OSTI)

The CO-concentration in the H.sub.2 feed stream to a PEM fuel cell stack is monitored by measuring current and voltage behavior patterns from an auxiliary cell attached to the end of the stack. The auxiliary cell is connected to the same oxygen and hydrogen feed manifolds that supply the stack, and discharges through a constant load. Pattern recognition software compares the current and voltage patterns from the auxiliary cell to current and voltage signature determined from a reference cell similar to the auxiliary cell and operated under controlled conditions over a wide range of CO-concentrations in the H.sub.2 fuel stream.

Meltser, Mark Alexander (Pittsford, NY)

1999-01-01T23:59:59.000Z

330

Pattern recognition monitoring of PEM fuel cell  

DOE Patents (OSTI)

The CO-concentration in the H{sub 2} feed stream to a PEM fuel cell stack is monitored by measuring current and voltage behavior patterns from an auxiliary cell attached to the end of the stack. The auxiliary cell is connected to the same oxygen and hydrogen feed manifolds that supply the stack, and discharges through a constant load. Pattern recognition software compares the current and voltage patterns from the auxiliary cell to current and voltage signature determined from a reference cell similar to the auxiliary cell and operated under controlled conditions over a wide range of CO-concentrations in the H{sub 2} fuel stream. 4 figs.

Meltser, M.A.

1999-08-31T23:59:59.000Z

331

Centralized wind power plant voltage control with optimal power flow algorithm.  

E-Print Network (OSTI)

??This thesis presents a method of controlling the reactive power injected into a medium-voltage collection system by multiple wind turbine generators such that the voltage… (more)

Kline, Jared Andrew

2011-01-01T23:59:59.000Z

332

Voltage stability limits for weak power systems with high wind penetration.  

E-Print Network (OSTI)

??Analysis of power system voltage stability has practical value in increasing wind penetration levels. As wind penetration levels increase in power systems, voltage stability challenges… (more)

Tamimi, Ala

2011-01-01T23:59:59.000Z

333

Improving the low voltage ride through of doubly fed induction generator during intermittent voltage source converter faults  

Science Conference Proceedings (OSTI)

The impact of different voltage source converter (VSC) faults on the low voltage ride through (LVRT) capability of the doubly fed induction generator (DFIG) is also investigated. Faults such as fire-through of the VSC switches and short circuit across the DC-link capacitor are considered in this paper. The impact of internal VSC faults when they occur within the grid side converter (GSC)

2013-01-01T23:59:59.000Z

334

A Multiphase, Modular, Bidirectional, Triple-Voltage DC-DC Converter Power Systems  

Science Conference Proceedings (OSTI)

Electrical power systems in future hybrid and fuel cell vehicles may employ three voltage [14 V, 42 V, and high voltage (HV)] nets. These will be necessary to accommodate existing 14-V loads as well as efficiently handle new heavy loads at the 42-V net and a traction drive on the HV bus. A low-cost DC-DC converter was proposed for connecting the three voltage nets. It minimizes the number of switches and their associated gate driver components by using two half-bridges and a high-frequency transformer. Another salient feature is that the half bridge on the 42-V bus is also utilized to provide the 14-V bus by operating at duty ratios around an atypical value of 1/3. Moreover, it makes use of the parasitic capacitance of the switches and the transformer leakage inductance for soft switching. The use of half bridges makes the topology well suited for interleaved multiphase modular configurations as a means to increase the power level because the capacitor legs can be shared. This paper presents simulation and experimental results on an interleaved two-phase arrangement rated at 4.5 kW. Also discussed are the benefits of operating with an atypical duty ratio on the transformer and a preferred multiphase configuration to minimize capacitor ripple currents.

Su, Gui-Jia [ORNL; Tang, Lixin [ORNL

2008-01-01T23:59:59.000Z

335

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1997-01-01T23:59:59.000Z

336

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

Shimer, D.W.; Lange, A.C.

1997-03-11T23:59:59.000Z

337

Interaction of Multiple Distributed Energy Resources in Voltage Regulation  

Science Conference Proceedings (OSTI)

Distributed energy resources (DE) with power electronics (PE) interfaces with the right control are capable of providing reactive power related ancillary services; voltage regulation in particular has drawn much attention. In this paper the problem of how to coordinate control multiple DEs to regulate the local voltage in the distribution system is addressed. A control method for voltage regulation using the DE PE controller is presented and based on the proposed control scheme; the voltage regulation of a distribution system with one DE and two DEs are tested, respectively. The factors affecting the gain parameters of the PE controller are investigated. The simulation results show that the parameters of the controller determine its dynamic response for voltage regulation and the factors associated with the network characteristics, such as locations of DEs and the amount of load, affect the impact range of the controller. The research work presented in this paper can be potentially used for the control system design of Smart Grid or Utility of the Future.

Li, Huijuan [University of Tennessee, Knoxville (UTK); Li, Fangxing [ORNL; Xu, Yan [ORNL; Rizy, D Tom [ORNL; Kueck, John D [ORNL

2008-01-01T23:59:59.000Z

338

Minimization of voltage deviation and power losses in power networks using Pareto optimization methods  

Science Conference Proceedings (OSTI)

Voltage regulation is an important task in electrical engineering for controlling node voltages in a power network. A widely used solution for the problem of voltage regulation is based on adjusting the taps in under load tap changers (ULTCs) power transformers ... Keywords: Multi-objective optimization, Power distribution network, Power losses, Under load tap changers, Voltage regulation

Francisco G. Montoya; Raúl Baños; Consolación Gil; Antonio Espín; Alfredo Alcayde; Julio Gómez

2010-08-01T23:59:59.000Z

339

Elevated voltage level I.sub.DDQ failure testing of integrated circuits  

DOE Patents (OSTI)

Burn in testing of static CMOS IC's is eliminated by I.sub.DDQ testing at elevated voltage levels. These voltage levels are at least 25% higher than the normal operating voltage for the IC but are below voltage levels that would cause damage to the chip.

Righter, Alan W. (Albuquerque, NM)

1996-01-01T23:59:59.000Z

340

Original article: Selective compensation of voltage harmonics in grid-connected microgrids  

Science Conference Proceedings (OSTI)

In this paper, a novel approach is proposed for selective compensation of main voltage harmonics in a grid-connected microgrid. The aim of compensation is to provide a high voltage quality at the point of common coupling (PCC). PCC voltage quality is ... Keywords: Distributed generator (DG), Grid-connected, Microgrid, Voltage harmonics compensation

Mehdi Savaghebi, Juan C. Vasquez, Alireza Jalilian, Josep M. Guerrero, Tzung-Lin Lee

2013-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Requirements for a Standard Test to Rate the Durability of PV Modules at System Voltage (Presentation)  

DOE Green Energy (OSTI)

Degradation modes in photovoltaic modules under system bias voltage stress are described and classified.

Hacke, P.; Terwilliger, K.; Glick, S.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-02-01T23:59:59.000Z

342

Voltage Stability/Security Assessment and On-Line Control: Volumes 1-4  

Science Conference Proceedings (OSTI)

To address growing utility concerns of voltage instability and possible voltage collapse, EPRI has developed a new voltage stability analysis package for large power systems, VSTAB. This off-line planning tool provides information on a utility power system's proximity to and mechanism of voltage instability.

1993-05-01T23:59:59.000Z

343

Impact of MOSFET's performance on its threshold voltage and its influence on design of MOS inverters  

Science Conference Proceedings (OSTI)

The aim of this paper is to research the impact of physical parameters which characterize the MOSFET transistors structure on the threshold voltage values and its influence on critical voltage values which characterize digital circuits that contain the ... Keywords: MOSFET parameters, critical values, doped density, enhancement-type NMOS, impurities, narrow-channel, propagation delay, short-channel, threshold voltage, voltage level

Milaim Zabeli; Nebi Caka; Myzafere Limani; Qamil Kabashi

2008-04-01T23:59:59.000Z

344

Experiment Hazard Class 13.0 - High Voltage  

NLE Websites -- All DOE Office Websites (Extended Search)

3.0 - High Voltage 3.0 - High Voltage Applicability This hazard classification applies to all experiments involving the use of High Voltage Equipment. Other hazard classifications and their associated hazard controls may also apply to experiments in this hazard class. The inspection of electric equipment is covered under the APS Policy For User Electric Equipment Inspections. NOTE: Unless required Argonne training has been completed, users are not authorized to perform electrical work. Experiment Category All Hazard Class 13 experiments are categorized as medium risk experiments. Experiment Hazard Control Verification Statements Engineered Controls - Determined by review and results of a DEEI inspection of the equipment. Procedural Controls - Determined by review and results of a DEEI

345

Dynamic Voltage Scaling on a Low-Power Microprocessor  

E-Print Network (OSTI)

Power consumption is the limiting factor for the functionality of future wearable devices. Since interactive applications like wireless information access generate bursts of activities, it is important to match the performance of the wearable device accordingly. This paper describes a system with a microprocessor whose speed can be varied (frequency scaling) as well as its input voltage. Voltage scaling is important for reducing power consumption to very low values when operating at low speeds. Measurements show that the energy per instruction at minimal speed (59 MHz) is 1/5 of the energy required at full speed (251 MHz). The frequency and voltage can be scaled dynamically from user space in only 140 ¡ s. This allows power-aware applications to quickly adjust the performance level of the processor whenever the workload changes. 1

Johan Pouwelse; Koen Langendoen; Henk Sips

2001-01-01T23:59:59.000Z

346

Proceedings: EPRI/NERC forum on voltage stability  

SciTech Connect

Over the past two decades, the interconnected electric systems serving North America have been increasingly subjected to reductions in generation and transmission capacity reserves, increasing complexity of load character, and the need for power transfer over longer distances. As a result, voltage stability limitations are becoming an important factor for utility personnel to consider when designing and operating an electric system. To address this situation, EPRI and NERC cosponsored a forum to exchange information between the various sectors of the utility industry on voltage control technology. The forum covered available tools and practices; utility operating practices, procedures, and experiences; planning and operating studies; and energy management system (EMS) vendor viewpoints. Participants agreed that a continuing coordinated effort involving all industry groups was needed in the voltage stability area. Attendees also identified specific subject areas of importance to help direct future studies. Individual papers are indexed separately.

Maratukulam, D. (ed.) (Kennedy (Thomas), Florissant, MO (United States))

1993-05-01T23:59:59.000Z

347

Phosphoric-acid fuel-cell stack and system development. Technical progress report, January 1-March 31, 1979  

DOE Green Energy (OSTI)

Primary emphasis during the period was on stack component development, Task I. However, effort is accelerating in the fuel processing sub-system area, Task II. Integrated system analysis, Task III, has begun, but the stack component scale-up effort, Task IV, will not start until later in 1979. Two three-cell stacks utilizing nominal 0.46 mg Pt/cm/sup 2/ electrodes were started on-test during the quarter. Routine electrolyte-additions were employed for one stack which exhibited good stability at 150 amp/ft/sup 2/ (161 ma/cm/sup 2/) over the 325 to 375/sup 0/F (163 to 191/sup 0/C) temperature range. Stack temperature was recently increased to 400/sup 0/F (204/sup 0/C), and this led to a noticeable decline in voltage. The second stack was subjected to shutdown/start-up cycles without electrolyte addition. CVD-upgraded reticulated vitreous carbon elements have shown good mechanical and electrical properties. Laminated matrix layers have served to lower the cell IR-losses substantially - to about 40 mv at 150 ma/ft/sup 2/.

Not Available

1979-01-01T23:59:59.000Z

348

Further Improvement of Aluminium Reduction Cell Resistance Slope ...  

Science Conference Proceedings (OSTI)

During the underfeeding regime from the lean side of the cell voltage vs alumina ... of Aluminum-alloy Welding Processes for Prediction of Hot Crack Formation.

349

Status of NexTech's Solid Oxide Fuel Cell Technology  

Science Conference Proceedings (OSTI)

Key demonstrations achieved to date include achieving targeted stack power outputs under conditions of high voltage (0.75 volts per cell) and high fuel ...

350

Simple Method Quantifies Recombination Pathways in Solar Cells (Fact Sheet)  

SciTech Connect

NREL's analytic equation uses open-circuit voltage data to determine how much recombination occurs via different channels in a solar cell.

Not Available

2013-09-01T23:59:59.000Z

351

Advancements of Dubal High Amperage Reduction Cell Technologies  

Science Conference Proceedings (OSTI)

Development of Low-Voltage Energy-Saving Aluminum Reduction Technology ... Energy Savings in Aluminum Electrolysis Cells: Effect of the Cathode Design.

352

Effects of Distributed Energy Resources on Conservation Voltage Reduction (CVR)  

SciTech Connect

Conservation Voltage Reduction (CVR) is one of the cheapest technologies which can be intelligently leveraged to provide considerable energy savings. The addition of renewables in the form of distributed resources can affect the entire power system, but more importantly, affects the traditional substation control schemes at the distribution level. This paper looks at the effect on energy consumption, peak load reduction, and voltage profile changes due to the addition of distributed generation in a distribution feeder using combinations of volt var control. An IEEE 13-node system is used to simulate the various cases. Energy savings and peak load reduction for different simulation scenarios are compared.

Singh, Ruchi; Tuffner, Francis K.; Fuller, Jason C.; Schneider, Kevin P.

2011-10-10T23:59:59.000Z

353

Voltage Control Devices on the IEEE 8500 Node Test Feeder  

SciTech Connect

The IEEE Test Cases provide researchers with distribution system models that can be used to validate new analytic methods. The newest of these models is the 8500-node test feeder which contains multiple devices for voltage control. In addition to a substation regulator there are multiple inline regulators as well as capacitor banks. This paper will discuss the detail in which voltage control devises should be modeled when examining large distribution systems. This discussion will include issues associated with power flow analysis for a single time step as well as for time series analysis.

Schneider, Kevin P.; Fuller, Jason C.

2010-01-06T23:59:59.000Z

354

Method of determining the open circuit voltage of a battery in a closed circuit  

SciTech Connect

The open circuit voltage of a battery which is connected in a closed circuit is determined without breaking the circuit or causing voltage upsets therein. The closed circuit voltage across the battery and the current flowing through it are determined under normal load and then a fractional change is made in the load and the new current and voltage values determined. The open circuit voltage is then calculated, according to known principles, from the two sets of values.

Brown, William E. (Walnut Creek, CA)

1980-01-01T23:59:59.000Z

355

Fuel cell system  

DOE Patents (OSTI)

A fuel cell system is comprised of a fuel cell module including sub-stacks of series-connected fuel cells, the sub-stacks being held together in a stacked arrangement with cold plates of a cooling means located between the sub-stacks to function as electrical terminals. The anode and cathode terminals of the sub-stacks are connected in parallel by means of the coolant manifolds which electrically connect selected cold plates. The system may comprise a plurality of the fuel cell modules connected in series. The sub-stacks are designed to provide a voltage output equivalent to the desired voltage demand of a low voltage, high current DC load such as an electrolytic cell to be driven by the fuel cell system. This arrangement in conjunction with switching means can be used to drive a DC electrical load with a total voltage output selected to match that of the load being driven. This arrangement eliminates the need for expensive voltage regulation equipment.

Early, Jack (Perth Amboy, NJ); Kaufman, Arthur (West Orange, NJ); Stawsky, Alfred (Teaneck, NJ)

1982-01-01T23:59:59.000Z

356

Fuel Cell Technical Team Roadmap  

NLE Websites -- All DOE Office Websites (Extended Search)

voltage degradation, as reported in K. Wipke et al., National Fuel Cell Electric Vehicle Learning Demonstration Final Report, NRELTP -5600-54860, July 2012, http:www.nrel.gov...

357

C17: Voltage Impulse Induced Bistable Magnetization Switching and ...  

Science Conference Proceedings (OSTI)

Non-violate dynamic magnetization switch was also realized by voltage impulse ... Concentric Nanoparticles Embedded in Low Temperature Synthesized TiO2 Films .... F2: Development of the On-Line Mechanical Property Prediction System for ... Sintered Nd-Fe-B Magnets by Transmission Electron Microscopy Analysis.

358

Ultra-compact Marx-type high-voltage generator  

DOE Patents (OSTI)

An ultra-compact Marx-type high-voltage generator includes individual high-performance components that are closely coupled and integrated into an extremely compact assembly. In one embodiment, a repetitively-switched, ultra-compact Marx generator includes low-profile, annular-shaped, high-voltage, ceramic capacitors with contoured edges and coplanar extended electrodes used for primary energy storage; low-profile, low-inductance, high-voltage, pressurized gas switches with compact gas envelopes suitably designed to be integrated with the annular capacitors; feed-forward, high-voltage, ceramic capacitors attached across successive switch-capacitor-switch stages to couple the necessary energy forward to sufficiently overvoltage the spark gap of the next in-line switch; optimally shaped electrodes and insulator surfaces to reduce electric field stresses in the weakest regions where dissimilar materials meet, and to spread the fields more evenly throughout the dielectric materials, allowing them to operate closer to their intrinsic breakdown levels; and uses manufacturing and assembly methods to integrate the capacitors and switches into stages that can be arranged into a low-profile Marx generator.

Goerz, David A. (Brentwood, CA); Wilson, Michael J. (Modesto, CA)

2000-01-01T23:59:59.000Z

359

High voltage gas insulated transmission line with continuous particle trapping  

DOE Patents (OSTI)

This invention provides a novel high voltage gas insulated transmission line utilizing insulating supports spaced at intervals with snap-in means for supporting a continuous trapping apparatus and said trapping apparatus having perforations and cutouts to facilitate trapping of contaminating particles and system flexibility.

Cookson, Alan H. (Pittsburgh, PA); Dale, Steinar J. (Monroeville, PA)

1983-01-01T23:59:59.000Z

360

Wire-Extrusion Process Disrupted By Voltage Sags  

Science Conference Proceedings (OSTI)

This PQTN Case Study investigates voltage sags originating from a utility distribution system at a wire-extrusion plant near Cleveland, Ohio that were causing a wire-drawing process to malfunction, resulting in broken tungsten wire and hours of time spent restarting the manufacturing process.

2003-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Smart Solar Home System with Safety Device Low Voltage Alert  

Science Conference Proceedings (OSTI)

For many reasons Bangladeshi people are now using renewable energy. So, solar energy is the best renewable energy till now, in respect of Bangladesh. So using of solar system is common nowadays. Bangladesh Government has taken some steps to make solar ... Keywords: Smart Solar Home System (SSHS), Rooftop, Safety Device, Low voltage alert

Tawheed Hasan; Md. Faysal Nayan; Md. Asif Iqbal; Monzurul Islam

2012-03-01T23:59:59.000Z

362

Current isolating epitaxial buffer layers for high voltage photodiode array  

DOE Patents (OSTI)

An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

2002-01-01T23:59:59.000Z

363

Design of Low Voltage Low Power Operational Amplifier  

Science Conference Proceedings (OSTI)

With the demand of low power applications, running circuits with reduced supply voltage can be of great advantage. Integrated circuit designers start to face a power wall as the most difficult constraints in new technology and circuit development are ... Keywords: Op Amp, CMOS, LVLP

Manju Sandhu; Manju Bala

2012-01-01T23:59:59.000Z

364

Rank based dynamic voltage and frequency scaling fortiled graphics processors  

Science Conference Proceedings (OSTI)

With increasing interest in sophisticated graphics capabilities in mobile systems, energy consumption of graphics hardware is becoming a major design concern in addition to the traditional performance enhancement criteria. Our study of various modern ... Keywords: dynamic voltage and frequency scaling, graphics processor, low power, workload prediction

B.V.N Silpa; Gummidipudi Krishnaiah; Preeti Ranjan Panda

2010-10-01T23:59:59.000Z

365

High voltage bipolar-CMOS structure using porous silicon  

DOE Patents (OSTI)

A method for integrating a silicon-on-insulator device and a bulk bipolar device on a semiconductor body. The invention simultaneously forms the two regions for the silicon-on-insulator device and the bipolar device. The invention enables a high voltage CMOS power device to be located on the same chip as a bipolar logic device enabling smart power devices.

Guilinger, T.R.; Kelly, M.J.; Tsao, S.S.

1990-01-01T23:59:59.000Z

366

Analysis on DFIG Wind Power System Low-Voltage Ridethrough  

Science Conference Proceedings (OSTI)

Due to the double fed induction generator’s (DFIG) advantage of controlling active and reactive power independently and partial power converter, DFIG is becoming a popular type of wind power generation system. Nowadays, the grid code demands that ... Keywords: VSCF, DFIG, LVRT, Crowbar, Voltage sags

Yulong Wang; Jianlin Li; Shuju Hu; Honghua Xu

2009-04-01T23:59:59.000Z

367

Power and Voltage Smooth Control of Doubly Fed Induction Generator  

Science Conference Proceedings (OSTI)

Doubly-fed induction generator (DFIG) is the leading in wind power technology currently. In this paper, decoupling control of DFIG is studied and a new energy storage device is used in the smooth control of DFIG system's power and voltage. This new method ... Keywords: Doubly fed induction generator, Energy storage device, Decoupling control

An-Ren Ma, Cai-Xia Wang, Zhi-Wen Zhou, Tao Wu

2012-07-01T23:59:59.000Z

368

Low-voltage cathodoluminescence of europium-activated yttrium orthovanadate  

Science Conference Proceedings (OSTI)

Emissive flat panel display systems operating in full color demand higher performance at low voltages (ca. 501000 V) from cathodoluminescent (CL) phosphors than cathode ray tubes require. Hydrothermal synthesis has been suggested as a route to phosphors with improved efficiencies, lower voltage thresholds, and increased saturation power. This hypothesis was tested in europium-doped yttrium orthovanadate (YVO{sub 4}:Eu), an efficient, red emitting CL phosphor. The CL efficiency of YVO{sub 4}:Eu crystallized from aqueous solution at 200{degrees}C is relatively low until it is annealed. The distribution of particle sizes in the low-temperature phosphor is similar to that in material made via a solid-state route, but crystallites remain much smaller (ca. 400 {Angstrom}) until they are annealed. These observations, along with the anomalously strong dependence of CL intensity on europium concentration, support a model in which efficiency principally depends on crystallite size. CL efficiency of both solid state and hydrothermal YVO{sub 4}:Eu increases with voltage at constant power. Surface-bound electrons are likely the dominant influence on efficiency at voltages near threshold. Saturation power is independent of synthetic route. It is apparent that the CL properties of hydrothermally synthesized YVO{sub 4}:Eu are essentially the same as those of YVO{sub 4}:Eu produced via conventional, high-temperature routes.

Phillips, M.L.F.

1995-03-01T23:59:59.000Z

369

Control Techniques to Eliminate Voltage Emergencies in High Performance Processors  

E-Print Network (OSTI)

negligible impact on perfor­ mance and energy. With the ITRS roadmap predicting aggres­ sive drops in supply. At present it is difficult to design a high quality, low impedance power supply system, and industry trends in current variability, often re­ ferred to as the dI/dt problem, can cause supply voltage fluc­ tuations

Martonosi, Margaret

370

Control Techniques to Eliminate Voltage Emergencies in High Performance Processors  

E-Print Network (OSTI)

negligible impact on perfor- mance and energy. With the ITRS roadmap predicting aggres- sive drops in supply. At present it is difficult to design a high quality, low impedance power supply system, and industry trends in current variability, often re- ferred to as the dI/dt problem, can cause supply voltage fluc- tuations

Gupta, Rajiv

371

High Voltage Laboratory Testing of Femtosecond Laser Lightning Diversion  

Science Conference Proceedings (OSTI)

Lightning strikes cost the electric power industry an estimated 1 billion dollars annually in damage and lost revenue. One possible way of protecting critical and susceptible facilities from lightning strikes is to use lasers to trigger and divert lightning along a predetermined path. This report describes laboratory research on the use of ultrashort UV pulses and near IR pulses to trigger high voltage discharge.

1998-12-09T23:59:59.000Z

372

Stability issues in IC Low Drop Out voltage regulators  

E-Print Network (OSTI)

Performance issues of IC Low Drop Out (LDO) voltage regulators, with specific reference to stability, are discussed in this thesis. Evaluation of existing frequency compensation schemes and their performances across operating loads is presented. The problem of instability of the LDO voltage regulator at low Electo Static Resistance (ESR) of the load capacitors and the consequences of this problem are highlighted. As a solution to some of the discussed problems, an alternate LDO voltage regulator topology that is stable with low Electro Static Resistance (ESR) capacitive loads is presented. The proposed scheme, instead of relying on the zero generated by the load capacitor and its ESR combination for stability, generates a zero internally. The LDO voltage regulator is implemented and fabricated in AMI 0.5mm CMOS technology through MOSIS service. It is demonstrated that this scheme realizes robust frequency compensation, facilitates use of Multi Layer Ceramic Capacitors (MLCC) for load of LDO regulators, and improves transient response and noise performance. Test results from the prototype provide an evaluation of the most important parameters of the regulator: ground current, load regulation, line regulation, output noise and start-up time.

Chava, Krishna Chaitanya

2002-01-01T23:59:59.000Z

373

A variable voltage MPPT control method for photovoltaic generation system  

Science Conference Proceedings (OSTI)

To increase the output efficiency of a photovoltaic (PV) generation system it is important to have an efficient maximum power point tracking (MPPT) technique. This paper describes the analysis, design and implementation of an efficient tracking method ... Keywords: maximum power point tracking (MPPT), photovoltaic generation system, pulse-width-modulation (PWM), solar energy, variable voltage

Liu Liqun; Wang Zhixin

2009-04-01T23:59:59.000Z

374

Voltage stability/security assessment and on-line control  

SciTech Connect

Project RP3040-1 was initiated in 1989, and concluded with the release of the Voltage Stability analysis program, VSTAB, in 1992. VSTAB is a production grade program for voltage stability assessment of large complex power systems. During the course of the RP3040-1, much effort was spent in developing a clear understanding of voltage stability and in defining the special modeling and analytical techniques required to accurately capture the phenomenon through simulation. The result was the development of new steady state methods which can complement the dynamic simulation methods currently available with EPRI's Extended Transient/Midterm Stability Program (ETMSP). VSTAB uses an enhanced powerflow combined with a specially developed modal analysis algorithm to provide information regarding both the proximity to, and mechanism of, voltage instability. The program is fast, easy to use, and comprehensive in both modeling and analysis features. This Programmer's Manual documents the structure and code details of VSTAB. It is intended as a reference document for those required to maintain or enhance the VSTAB program. For details on analytical techniques used in the program, readers are directed to the VSTAB Application Guide and Final Report for project RP3040-1.

Morison, G.K.; Gao, B.; Hamadanizadeh, H. (Ontario Hydro, Toronto, ON (Canada))

1993-04-01T23:59:59.000Z

375

Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids  

E-Print Network (OSTI)

Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids Mehdi@et.aau.dk Abstract-- The concept of microgrid hierarchical control is presented, recently. In this paper, a hierarchical scheme which includes primary and secondary control levels is proposed for islanded microgrids

Vasquez, Juan Carlos

376

Low Beam Voltage, 10 MW, L-Band Cluster Klystron  

SciTech Connect

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

Teryaev, V.; /Novosibirsk, IYF; Yakovlev, V.P.; /Fermilab; Kazakov, S.; /KEK, Tsukuba; Hirshfield, J.L.; /Yale U. /Omega-P, New Haven

2009-05-01T23:59:59.000Z

377

The call to adopt a nominal set of astrophysical parameters and constants to improve the accuracy of fundamental physical properties of stars  

E-Print Network (OSTI)

The increasing precision of astronomical observations of stars and stellar systems is gradually getting to a level where the use of slightly different values of the solar mass, radius and luminosity, as well as different values of fundamental physical constants may lead to measurable systematic differences in the determination of basic physical properties. An equivalent issue with an inconsistent value of the speed of light was resolved by adopting a nominal value that is constant and has no error associated with it. Analogously, we suggest that the systematic error in stellar parameters may be avoided if the following two conditions are met: (1) we deprecate the usage of solar quantities Msun, Rsun, and Lsun as units and replace them by the nominal values that are by definition exact and expressed in SI units: 1 MnomSun = 1.988416 x 10^{30} kg, 1 RnomSun = 6.95508 x 10^8 m, and 1 LnomSun = 3.846 x 10^{26} W; and (2) each study containing a determination of fundamental properties of stars or stellar systems s...

Harmanec, Petr

2011-01-01T23:59:59.000Z

378

Membrane Purification Cell for Aluminum Recycling  

Science Conference Proceedings (OSTI)

Recycling mixed aluminum scrap usually requires adding primary aluminum to the scrap stream as a diluent to reduce the concentration of non-aluminum constituents used in aluminum alloys. Since primary aluminum production requires approximately 10 times more energy than melting scrap, the bulk of the energy and carbon dioxide emissions for recycling are associated with using primary aluminum as a diluent. Eliminating the need for using primary aluminum as a diluent would dramatically reduce energy requirements, decrease carbon dioxide emissions, and increase scrap utilization in recycling. Electrorefining can be used to extract pure aluminum from mixed scrap. Some example applications include producing primary grade aluminum from specific scrap streams such as consumer packaging and mixed alloy saw chips, and recycling multi-alloy products such as brazing sheet. Electrorefining can also be used to extract valuable alloying elements such as Li from Al-Li mixed scrap. This project was aimed at developing an electrorefining process for purifying aluminum to reduce energy consumption and emissions by 75% compared to conventional technology. An electrolytic molten aluminum purification process, utilizing a horizontal membrane cell anode, was designed, constructed, operated and validated. The electrorefining technology could also be used to produce ultra-high purity aluminum for advanced materials applications. The technical objectives for this project were to: - Validate the membrane cell concept with a lab-scale electrorefining cell; - Determine if previously identified voltage increase issue for chloride electrolytes holds for a fluoride-based electrolyte system; - Assess the probability that voltage change issues can be solved; and - Conduct a market and economic analysis to assess commercial feasibility. The process was tested using three different binary alloy compositions (Al-2.0 wt.% Cu, Al-4.7 wt.% Si, Al-0.6 wt.% Fe) and a brazing sheet scrap composition (Al-2.8 wt.% Si-0.7 wt.% Fe-0.8 wt.% Mn),. Purification factors (defined as the initial impurity concentration divided by the final impurity concentration) of greater than 20 were achieved for silicon, iron, copper, and manganese. Cell performance was measured using its current and voltage characteristics and composition analysis of the anode, cathode, and electrolytes. The various cells were autopsied as part of the study. Three electrolyte systems tested were: LiCl-10 wt. % AlCl3, LiCl-10 wt. % AlCl3-5 wt.% AlF3 and LiF-10 wt.% AlF3. An extended four-day run with the LiCl-10 wt.% AlCl3-5 wt.% AlF3 electrolyte system was stable for the entire duration of the experiment, running at energy requirements about one third of the Hoopes and the conventional Hall-Heroult process. Three different anode membranes were investigated with respect to their purification performance and survivability: a woven graphite cloth with 0.05 cm nominal thickness & > 90 % porosity, a drilled rigid membrane with nominal porosity of 33%, and another drilled rigid graphite membrane with increased thickness. The latter rigid drilled graphite was selected as the most promising membrane design. The economic viability of the membrane cell to purify scrap is sensitive to primary & scrap aluminum prices, and the cost of electricity. In particular, it is sensitive to the differential between scrap and primary aluminum price which is highly variable and dependent on the scrap source. In order to be economically viable, any scrap post-processing technology in the U.S. market must have a total operating cost well below the scrap price differential of $0.20-$0.40 per lb to the London Metal Exchange (LME), a margin of 65%-85% of the LME price. The cost to operate the membrane cell is estimated to be aluminum. The energy cost is estimated to be $0.05/lb of purified aluminum with the remaining costs being repair and maintenance, electrolyte, labor, taxes and depreciation. The bench-scale work on membrane purification cell process has demonstrated technological advantages and subs

David DeYoung; James Wiswall; Cong Wang

2011-11-29T23:59:59.000Z

379

Membrane Purification Cell for Aluminum Recycling  

SciTech Connect

Recycling mixed aluminum scrap usually requires adding primary aluminum to the scrap stream as a diluent to reduce the concentration of non-aluminum constituents used in aluminum alloys. Since primary aluminum production requires approximately 10 times more energy than melting scrap, the bulk of the energy and carbon dioxide emissions for recycling are associated with using primary aluminum as a diluent. Eliminating the need for using primary aluminum as a diluent would dramatically reduce energy requirements, decrease carbon dioxide emissions, and increase scrap utilization in recycling. Electrorefining can be used to extract pure aluminum from mixed scrap. Some example applications include producing primary grade aluminum from specific scrap streams such as consumer packaging and mixed alloy saw chips, and recycling multi-alloy products such as brazing sheet. Electrorefining can also be used to extract valuable alloying elements such as Li from Al-Li mixed scrap. This project was aimed at developing an electrorefining process for purifying aluminum to reduce energy consumption and emissions by 75% compared to conventional technology. An electrolytic molten aluminum purification process, utilizing a horizontal membrane cell anode, was designed, constructed, operated and validated. The electrorefining technology could also be used to produce ultra-high purity aluminum for advanced materials applications. The technical objectives for this project were to: - Validate the membrane cell concept with a lab-scale electrorefining cell; - Determine if previously identified voltage increase issue for chloride electrolytes holds for a fluoride-based electrolyte system; - Assess the probability that voltage change issues can be solved; and - Conduct a market and economic analysis to assess commercial feasibility. The process was tested using three different binary alloy compositions (Al-2.0 wt.% Cu, Al-4.7 wt.% Si, Al-0.6 wt.% Fe) and a brazing sheet scrap composition (Al-2.8 wt.% Si-0.7 wt.% Fe-0.8 wt.% Mn),. Purification factors (defined as the initial impurity concentration divided by the final impurity concentration) of greater than 20 were achieved for silicon, iron, copper, and manganese. Cell performance was measured using its current and voltage characteristics and composition analysis of the anode, cathode, and electrolytes. The various cells were autopsied as part of the study. Three electrolyte systems tested were: LiCl-10 wt. % AlCl3, LiCl-10 wt. % AlCl3-5 wt.% AlF3 and LiF-10 wt.% AlF3. An extended four-day run with the LiCl-10 wt.% AlCl3-5 wt.% AlF3 electrolyte system was stable for the entire duration of the experiment, running at energy requirements about one third of the Hoopes and the conventional Hall-Heroult process. Three different anode membranes were investigated with respect to their purification performance and survivability: a woven graphite cloth with 0.05 cm nominal thickness & > 90 % porosity, a drilled rigid membrane with nominal porosity of 33%, and another drilled rigid graphite membrane with increased thickness. The latter rigid drilled graphite was selected as the most promising membrane design. The economic viability of the membrane cell to purify scrap is sensitive to primary & scrap aluminum prices, and the cost of electricity. In particular, it is sensitive to the differential between scrap and primary aluminum price which is highly variable and dependent on the scrap source. In order to be economically viable, any scrap post-processing technology in the U.S. market must have a total operating cost well below the scrap price differential of $0.20-$0.40 per lb to the London Metal Exchange (LME), a margin of 65%-85% of the LME price. The cost to operate the membrane cell is estimated to be < $0.24/lb of purified aluminum. The energy cost is estimated to be $0.05/lb of purified aluminum with the remaining costs being repair and maintenance, electrolyte, labor, taxes and depreciation. The bench-scale work on membrane purification cell process has demonstrated technological advantages and subs

David DeYoung; James Wiswall; Cong Wang

2011-11-29T23:59:59.000Z

380

Sulfone-based electrolytes for high voltage li-ion batteries.  

Science Conference Proceedings (OSTI)

Sulfone-based electrolytes have been investigated as electrolytes for lithium-ion cells using high-voltage positive electrodes, such as LiMn{sub 2}O{sub 4} and LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} spinels, and Li{sub 4}Ti{sub 5}O{sub 12} spinel as negative electrode. In the presence of imide salt (LiTFSI) and ethyl methyl sulfone or tetramethyl sulfone (TMS) electrolytes, the Li{sub 4}Ti{sub 5}O{sub 12}/LiMn{sub 2}O{sub 4} cell exhibited a specific capacity of 80 mAh g{sup -1} with an excellent capacity retention after 100 cycles. In a cell with high-voltage LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} positive electrode and 1 M LiPF{sub 6} in TMS as electrolyte, the capacity reached 110 mAh g{sup -1} at the C/12 rate. When TMS was blended with ethyl methyl carbonate, the Li{sub 4}Ti{sub 5}O{sub 12}/LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} cell delivered an initial capacity of 80 mAh g{sup -1} and cycled fairly well for 1000 cycles under 2C rate. The exceptional electrochemical stability of the sulfone electrolytes and their compatibility with the Li{sub 4}Ti{sub 5}O{sub 12} safer and stable anode were the main reason behind the outstanding electrochemical performance observed with high-potential spinel cathode materials. These electrolytes could be promising alternative electrolytes for high-energy density battery applications such as plug-in hybrid and electric vehicles that require a long cycle life.

Abouimrane, A.; Belharouak, I.; Amine, K. (Chemical Sciences and Engineering Division)

2009-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

High-voltage supply for neutron tubes in well-logging applications  

DOE Patents (OSTI)

A high voltage supply is provided for a neutron tube used in well logging. The biased pulse supply of the invention combines DC and full pulse techniques and produces a target voltage comprising a substantial negative DC bias component on which is superimposed a pulse whose negative peak provides the desired negative voltage level for the neutron tube. The target voltage is preferably generated using voltage doubling techniques and employing a voltage source which generates bipolar pulse pairs having an amplitude corresponding to the DC bias level.

Humphreys, D.R.

1982-09-15T23:59:59.000Z

382

Guidelines for Working at Voltages < 240 Volts  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidelines for Working at Voltages < 240 Volts Guidelines for Working at Voltages < 240 Volts February 4, 2005---DRAFT NOTE: Working hot is a LAST ALTERNATIVE. Electrical hot work is defined as: Working on or near exposed conducting parts that are or might become energized at 50V or more. Refer to Electrical Safety Flowchart for Working On or Near Live Parts. Engineered methods to prevent exposed sources of 50V and greater are to be implemented wherever practical. Only QUALIFIED PERSONNEL {as defined in NFPA 70E Article 110.6(D) 2004 edition} as authorized by the CAT/supervisor/division can perform such work. Refer to Qualified Electrical Worker Flow Chart. Training requirements: ES&H 114 (LOTO) / ES&H 375 (NFPA 70E) / ES&H 371 (electrical worker) - Observe Electrical Safe Work Practices. Refer to

383

Blocking diodes and fuses in low-voltage PV systems  

DOE Green Energy (OSTI)

Instructions and labels supplied with listed PV modules and the requirements of the National Electrical Code (NEC) dictate that a series fuse shall be used to protect the module against backfeed currents. Few of the hundreds of thousands of low-voltage (12, 24, and 48-volt) stand-alone photovoltaic (PV) power systems use series fuses on each module or string of modules. Tests and simulations at the Southwest Technology Development Institute (TDI) and at Sandia National Laboratories (SNL) have established that the absence of these fuses can pose significant fire and safety hazards even on 12-volt PV systems. If the system has sufficient backfeed voltage and current, it is possible that a ground fault in the wiring or inside a module can result in the destruction of a PV module.

Wiles, J.C. [New Mexico State Univ., Las Cruces, NM (United States). Southwest Technology Development Inst.; King, D.L. [Sandia National Labs., Albuquerque, NM (United States). Photovoltaic Systems R and D

1997-11-01T23:59:59.000Z

384

Evaluation of Conservation Voltage Reduction (CVR) on a National Level  

SciTech Connect

Conservation Voltage Reduction (CVR) is a reduction of energy consumption resulting from a reduction of feeder voltage. While there have been numerous CVR systems deployed in North America there has been little substantive analytic analysis of the effect; the majority of the published results are based on empirical field measurements. Since these results are based on empirical measurements it is difficult to extrapolate how this technology will behave on the various types of distribution feeders found throughout the nation. This report has utilized the Taxonomy of Prototypical feeder developed under the Modern Grid Initiative (MGI), now the Modern Grid Strategy (MGS), in order to estimate the benefits of CVR on multiple distribution feeder types. This information will then be used to determine an estimate of the national benefits of a wide scale deployment of CVR.

Schneider, Kevin P.; Fuller, Jason C.; Tuffner, Francis K.; Singh, Ruchi

2010-09-29T23:59:59.000Z

385

Laser beam apparatus and method for analyzing solar cells  

DOE Patents (OSTI)

A laser beam apparatus and method for analyzing, inter alia, the current versus voltage curve at the point of illumination on a solar cell and the open circuit voltage of a solar cell. The apparatus incorporates a lock-in amplifier, and a laser beam light chopper which permits the measurement of the AC current of the solar cell at an applied DC voltage at the position on the solar cell where the cell is illuminated and a feedback scheme which permits the direct scanning measurements of the open circuit voltage. The accuracy of the measurement is a function of the intensity and wavelength of the laser light with respect to the intensity and wavelength distribution of sunlight and the percentage the dark current is at the open circuit voltage to the short circuit current of the solar cell.

Staebler, David L. (Lawrenceville, NJ)

1980-01-01T23:59:59.000Z

386

Field Guide: Compressors for High-Voltage Circuit Breakers  

Science Conference Proceedings (OSTI)

High-voltage circuit breakers (HVCBs) perform essential protection and control functions on power transmission networks. Circuit breakers have multiple components that must operate in concert in order for the breaker to perform properly. If one component, such as the air or hydraulic system, does not operate correctly, the circuit breaker may misoperate or fail, possibly resulting in equipment damage or an outageboth expensive consequences. To help utilities prevent such undesirable events, this field gu...

2010-12-22T23:59:59.000Z

387

Field Guide: Compressors for High-Voltage Circuit Breakers  

Science Conference Proceedings (OSTI)

High-voltage circuit breakers (HVCBs) perform essential protection and control functions on power transmission networks. Circuit breakers have multiple components that must operate in concert in order for the breaker to perform properly. If one component, such as the air or hydraulic system, does not operate correctly, the circuit breaker may misoperate or fail, possibly resulting in equipment damage or an outage—both expensive consequences. To help ...

2012-12-14T23:59:59.000Z

388

Nano-Composite Dielectrics on Medium-Voltage Model Cables  

Science Conference Proceedings (OSTI)

EPRI early recognized the potential for nanotechnology in power distribution and started a program in 2003 to explore the possibilities of using the technology to enhance the properties of high-voltage (HV) cable dielectrics based on both polyethylene and on ethylene-propylene rubber. This research resulted in encouraging findings, particularly for a formulation based on functionalized silicon dioxide nanoparticles in a cross-linked polyethylene (XLPE) polymer. Following this success, EPRI entered into a...

2007-12-19T23:59:59.000Z

389

High Voltage Direct Current (HVDC) Transmission Reference Book  

Science Conference Proceedings (OSTI)

The EPRI High-Voltage Direct Current (HVDC) Transmission Reference Book is a state-of-the-art guidebook that provides transmission companies with a comprehensive, single source of technical information and guidance for designing, building, operating, and extending the life of HVDC transmission systems. The book joins the landmark series of EPRI power delivery reference books. These comprehensive guidebooks—each printed with a distinctive colored cover—document and distill the ...

2012-12-31T23:59:59.000Z

390

Field Guide: High-Voltage Circuit Breaker Compressors – 2013 Update  

Science Conference Proceedings (OSTI)

High-voltage circuit breakers (HVCBs) perform essential protection and control functions on power transmission networks. Circuit breaker mechanisms have multiple components that must operate in concert in order for the breaker to perform properly. If one component, such as the air or hydraulic system, does not operate correctly, the circuit breaker may mis-operate or fail. A circuit breaker mis-operation may cause equipment damage and outages—both ...

2013-12-19T23:59:59.000Z

391

High-Voltage Direct Current Line Conductor Optimization  

Science Conference Proceedings (OSTI)

Overhead transmission lines are designed to last for 40 years. Many ac lines in service today in North America are 70 or more years old. This survival rate is a result of conservative utility design practices and detailed product specifications. This reliability record has occurred despite a wide range of conductor types and sizes. In the present transmission system, there are far fewer high-voltage direct current (HVDC) lines, but those that have been designed and built have been similarly successful in...

2011-12-21T23:59:59.000Z

392

Determination of the 5 MW gross nominal design case binary cycle for power generation at Raft River, Idaho. [Using GEOSYS program  

DOE Green Energy (OSTI)

A series of Rankine cycle studies for power generation utilizing geothermal fluid as the heat source and isobutane as the working fluid are reported. To find the plant configuration which would most effectively utilize the available energy, a parametric study was performed. The desirability of supercritical, single boiler or double boiler cycles, and the relative boiler temperatures and percentage isobutane flow split between the boilers in the double cycles for geothermal fluid temperatures of 260/sup 0/F to 360/sup 0/F were considered. This study was designed to discover thermodynamic trends which would point to an optimum isobutane cycle for geothermal fluid temperatures in this temperature range. The results of the parametric study were applied to derive a Nominal Design Case for a demonstration plant at Raft River, with a geothermal fluid resource at 290/sup 0/F. In addition, plant variations due to tolerances applied to thermodynamic properties and other key factors are included.

Ingvarsson, I.J.; Madsen, W.W. (eds.)

1976-12-01T23:59:59.000Z

393

Fiber optic current monitor for high-voltage applications  

DOE Patents (OSTI)

A current monitor which derives its power from the conductor being measured for bidirectionally measuring the magnitude of current (from DC to above 50 khz) flowing through a conductor across which a relatively high level DC voltage is applied, includes a pair of identical transmitter modules connected in opposite polarity to one another in series with the conductor being monitored, for producing from one module a first light signal having an intensity directly proportional to the magnitude of current flowing in one direction through the conductor during one period of time, and from the other module a second light signal having an intensity directly proportional to the magnitude of current flowing in the opposite direction through the conductor during another period of time, and a receiver located in a safe area remote from the high voltage area for receiving the first and second light signals, and converting the same to first and second voltage signals having levels indicative of the magnitude of current being measured at a given time. 6 figs.

Renda, G.F.

1992-04-21T23:59:59.000Z

394

765kV Transmission line Voltage gradient  

E-Print Network (OSTI)

Corona ring Transmission lines Nowadays, due to the ever increasing energy consumption and power supply optimization, it is required to construct new power plants, substations and transmission lines. In Iran, also, because of increasing demand for electrical energy, for a significant power loss reduction in power transmission over long distances, and to construct high transmission lines that lead to reduction in the economic costs of transmission lines, the transmission lines must be considered at extra high voltage (EHV) levels. These EHV levels should be compared with the low voltage levels in order to extract the benefits. Therefore, in this paper, a review has been conducted on the types of 765 kV transmission lines used in different countries and a comparison between them and the low voltage levels have been performed. Accordingly, the advantages of EHV transmission lines are summarized. Finally, designing a line of 765 kV single-circuit with 6 conductors per bundle based on existing standards is presented.

unknown authors

2012-01-01T23:59:59.000Z

395

Advanced Gate Drive for the SNS High Voltage Converter Modulator  

SciTech Connect

SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

396

Understanding the unbalanced-voltage problem in wind turbine generation  

DOE Green Energy (OSTI)

Most wind turbines are equipped with line-connected induction generators. Induction generators are very attractive as wind turbine generators due to their low cost, ruggedness and the need for little or no maintenance. At constant frequency, the induction generator operates in a small range of speeds and, therefore, it operated with a small range of slips with respect to synchronous speed. Compared to a synchronous generator, an induction generator provides lower stiffness, thus alleviating the mechanical stress. In a weak power system network, an unbalanced load at the distribution lines can cause unbalanced voltage conditions. If an induction generator is connected to an unbalanced voltage, the resulting stator current will be unbalanced. The unbalanced current creates unequal heating (hot spots) on the stator winding. The heat may increase the winding temperature, which degrades the insulation of the winding, i.e., the life expectancy of the winding. Unbalanced currents also create torque pulsation on the shaft resulting in audible noise and extra mechanical stress. This paper explores the unbalanced voltage problem in induction generators. The levels of unbalance and the loads are varied. Experimental and predicted results are presented in this paper.

Muljadi, E.; Butterfield, C.P.; Batan, T.; Yildirim, D.

2000-02-28T23:59:59.000Z

397

Ultra-low voltage resonant tunnelling diode electroabsorption modulator  

E-Print Network (OSTI)

Embedding a double barrier resonant tunnelling diode (RTD) in an unipolar InGaAlAs optical waveguide gives rise to a very low driving voltage electroabsorption modulator (EAM) at optical wavelengths around 1550 nm. The presence of the RTD within the waveguide core introduces high non-linearity and negative differential resistance in the current-voltage (I-V) characteristic of the waveguide. This makes the electric field distribution across the waveguide core strongly dependent on the bias voltage: when the current decreases from the peak to the valley there is an increase of the electric field across the depleted core. The electric field enhancement in the core-depleted layer causes the Franz-Keldysh absorption band-edge to red shift, which is responsible for the electroabsorption effect. High frequency ac signals as low as 100 mV can induce electric field high speed switching, producing substantial light modulation (up to 15 dB) at photon energies slightly lower than the waveguide core band-gap energy. The k...

Figueiredo, J M L; Stanley, C R

2002-01-01T23:59:59.000Z

398

Near independence of OLED operating voltage on transport layer thickness  

SciTech Connect

We report organic light emitting devices (OLEDs) with weak drive voltage dependence on the thickness of the hole transport layer (HTL) for thicknesses up to 1150 Å using the N,N?-Bis(naphthalen-1-yl)-N,N?-bis(phenyl)-benzidine (?-NPD) and N,N'-bis(3-methyl phenyl)-N,N'-diphenyl-[1,1'-biphenyl]-4,4'diamine (TPD), both of which have hole mobilities in the range of 2 × 10-3 cm2V-1s-1. Lower mobility HTL materials show larger operating voltage dependence on thickness. The near independence of the operating voltage for high mobility transport material thickness was only observed when the energy barrier for charge injection into the transport material was minimized. To ensure low injection barriers, a thin film of 2-(3-(adamantan-1-yl)propyl)-3,5,6-trifluorotetracyanoquinodimethane (F3TCNQ-Adl) was cast from solution onto the ITO surface. These results indicate that thick transport layers can be integrated into OLED stacks without the need for bulk conductivity doping.

Swensen, James S.; Wang, Liang (Frank) [Frank; Polikarpov, Evgueni; Rainbolt, James E.; Koech, Phillip K.; Cosimbescu, Lelia; Padmaperuma, Asanga B.

2013-01-01T23:59:59.000Z

399

Research on Low-Voltage Ride-Through Technology of Doubly-Fed VSCF Wind Power Generation System  

Science Conference Proceedings (OSTI)

Currently, some of the variable speed wind turbine on market have some low-voltage through capacity?LVRT?, but do not have dynamic reactive power support capacity under fault. DFIG can’t provide dynamic voltage support, in addition, ... Keywords: wind power, voltage dip, low voltage ride-through (LVRT), transient voltage control, rotor-side converter

Bao Wei; Yin Zhongdong

2009-10-01T23:59:59.000Z

400

Causal factors in the variation of the cell voltage in industrial aluminium smelting cells.  

E-Print Network (OSTI)

??The Hall-He?roult process is used for the production of the primary aluminium metal. This process consists of the electrochemical reduction of alumina (aluminium oxide) dissolved… (more)

Tandon, Gaurav

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Interline photovoltaic (I-PV) power plants for voltage unbalance compensation  

E-Print Network (OSTI)

This paper proposes a stationary-frame control method for voltage unbalance compensation using Interline Photovoltaic (I-PV) power system. I-PV power systems are controlled to compensate voltage unbalance autonomously. The ...

Moawwad, Ahmed

402

BB5, Nearly Ideal Current-Voltage Characteristics of Schottky Barrier ...  

Science Conference Proceedings (OSTI)

Recently, high-quality GaN free-standing substrates are available by various methods. ... Current-voltage (I-V) characteristics and capacitance-voltage (C-V) ...

403

A low-voltage zero-crossing-based delta-sigma analog-to-digital converter  

E-Print Network (OSTI)

A zero-crossing-based (ZCB) switched-capacitor technique is presented for operation under low power supply voltages without gate boosting. Voltage ramp generators maintain common-mode level at each integrator output. ...

Guyton, Matthew C. (Matthew Christopher)

2010-01-01T23:59:59.000Z

404

A low-noise bandgap voltage reference employing dynamic element matching  

E-Print Network (OSTI)

Bandgap voltages references are widely used in IC design, but are sensitive to low-frequency noise and component mismatch. This thesis describes the design and testing of a new IC voltage reference that targets these issues ...

Herbst, Steven (Steven G.)

2011-01-01T23:59:59.000Z

405

Voltage holding study of 1 MeV accelerator for ITER neutral beam injectora)  

Science Conference Proceedings (OSTI)

Voltage holding test on MeV accelerator indicated that sustainable voltage was a half of that of ideal quasi-Rogowski electrode. It was suggested that the emission of the clumps is enhanced by a local electric field concentration

M. Taniguchi; M. Kashiwagi; N. Umeda; M. Dairaku; J. Takemoto; H. Tobari; K. Tsuchida; H. Yamanaka; K. Watanabe; A. Kojima; M. Hanada; K. Sakamoto; T. Inoue

2012-01-01T23:59:59.000Z

406

Monitoring Volume Transport through Measurement of Cable Voltage across the Korea Strait  

Science Conference Proceedings (OSTI)

Voltage induced by the Tsushima Current on an abandoned submarine telephone cable between Pusan, Korea, and Hamada, Japan, has been measured since March 1998 in order to monitor the volume transport through the Korea Strait. Voltage has a good ...

Kuh Kim; Sang Jin Lyu; Young-Gyu Kim; Byung Ho Choi; Keisuke Taira; Henry T. Perkins; William J. Teague; Jeffrey W. Book

2004-04-01T23:59:59.000Z

407

Lipon Coatings for High Voltage and High Temperature Li-Ion ...  

use of high-capacity and high-voltage cathode materials, but charging to voltages approaching 4.5-5V invariably causes rapid loss of capacity with cycling.

408

Technology Assessment and Application Guide for the Utility Systems Technologies Voltage Sag Fighter  

Science Conference Proceedings (OSTI)

Voltage sag, a disturbance in a power system defined as a decrease in root mean square (RMS) voltage magnitude lasting from 0.5 to 30 cycles, has been identified as the most prevalent power disturbance experienced by industrial customers. The higher frequency of voltage sages makes them inherently more costly than interruptions since fault-induced, short-duration voltage variations can result in costly loss of production, damaged materials, repair and cleaning of equipment, and lost business opportunitie...

2010-11-29T23:59:59.000Z

409

A Hybrid Framework for Voltage Security Assessment Integrating Simulation and Measurement Based Approaches  

Science Conference Proceedings (OSTI)

Voltage stability is the ability of a power system to maintain adequate voltage magnitudes at buses, which is a major concern in daily power system operations and a leading factor to limit power transfers in a prevailing open-access environment. Currently, simulation-based voltage security assessment (VSA) tools are applied widely by electric utilities to analyze either steady-state or transient voltage stability issues. Those VSA tools can help operators foresee the next critical ...

2012-12-31T23:59:59.000Z

410

Strategies for Voltage Control and Transient Stability Assessment  

SciTech Connect

As wind generation grows, its influence on power system performance will becoming increasingly noticeable. Wind generation di#11;ffers from traditional forms of generation in numerous ways though, motivating the need to reconsider the usual approaches to power system assessment and performance enhancement. The project has investigated the impact of wind generation on transient stability and voltage control, identifying and addressing issues at three distinct levels of the power system: 1) at the device level, the physical characteristics of wind turbine generators (WTGs) are quite unlike those of synchronous machines, 2) at the wind-farm level, the provision of reactive support is achieved through coordination of numerous dissimilar devices, rather than straightforward generator control, and 3) from a systems perspective, the location of wind-farms on the sub-transmission network, coupled with the variability inherent in their power output, can cause complex voltage control issues. The project has sought to develop a thorough understanding of the dynamic behaviour of type-3 WTGs, and in particular the WECC generic model. The behaviour of such models is governed by interactions between the continuous dynamics of state variables and discrete events associated with limits. It was shown that these interactions can be quite complex, and may lead to switching deadlock that prevents continuation of the trajectory. Switching hysteresis was proposed for eliminating deadlock situations. Various type-3 WTG models include control blocks that duplicate integrators. It was shown that this leads to non-uniqueness in the conditions governing steady-state, and may result in pre- and post-disturbance equilibria not coinciding. It also gives rise to a zero eigenvalue in the linearized WTG model. In order to eliminate the anomalous behaviour revealed through this investigation, WECC has now released a new generic model for type-3 WTGs. Wind-farms typically incorporate a variety of voltage control equipment including tapchanging transformers, switched capacitors, SVCs, STATCOMs and the WTGs themselves. The project has considered the coordinated control of this equipment, and has addressed a range of issues that arise in wind-farm operation. The #12;first concerns the ability of WTGs to meet reactive power requirements when voltage saturation in the collector network restricts the reactive power availability of individual generators. Secondly, dynamic interactions between voltage regulating devices have been investigated. It was found that under certain realistic conditions, tap-changing transformers may exhibit instability. In order to meet cost, maintenance, fault tolerance and other requirements, it is desirable for voltage control equipment to be treated as an integrated system rather than as independent devices. The resulting high-level scheduling of wind-farm reactive support has been investigated. In addressing this control problem, several forms of future information were considered, including exact future knowledge and stochastic predictions. Deterministic and Stochastic Dynamic Programming techniques were used in the development of control algorithms. The results demonstrated that while exact future knowledge is very useful, simple prediction methods yield little bene#12;fit. The integration of inherently variable wind generation into weak grids, particularly subtransmission networks that are characterized by low X=R ratios, aff#11;ects bus voltages, regulating devices and line flows. The meshed structure of these networks adds to the complexity, especially when wind generation is distributed across multiple nodes. A range of techniques have been considered for analyzing the impact of wind variability on weak grids. Sensitivity analysis, based on the power-flow Jacobian, was used to highlight sections of a system that are most severely a#11;ffected by wind-power variations. A continuation power flow was used to determine parameter changes that reduce the impact of wind-power variability. It was also used to explore interactions betw

Hiskens, Ian A.

2013-09-25T23:59:59.000Z

411

A high-voltage low-power DC-DC buck regulator for automotive applications  

Science Conference Proceedings (OSTI)

This work presents a High-Voltage Low-Power CMOS DC-DC buck regulator for automotive applications. The overall system, including the high and low voltage analog devices, the power MOS and the low voltage digital devices, was realized in the Austriamicrosystems ... Keywords: DC-DC regulator, buck converter, current control, low quiscent current, pulse frequency modulation

G. Pasetti; L. Fanucci; R. Serventi

2010-03-01T23:59:59.000Z

412

Connectivity and Bidirectional Energy Transfer in DC Microgrid Featuring Different Voltage Characteristics  

Science Conference Proceedings (OSTI)

In this paper, the connectivity issues related to linking two DC buses featuring different voltage characteristics, in terms of voltage level and ripple, in a DC micro grid are identified, analyzed and discussed. A controlled DC-DC converter was used ... Keywords: Bidirectional energy transfer, buck-boost converter, DC distribution systems, DC microgrids, voltage ripple

Mustafa Farhadi, Ahmed Mohamed, Osama Mohammed

2013-04-01T23:59:59.000Z

413

Modeling and simulation of new configuration of dynamic voltage restorer for power quality improvement  

Science Conference Proceedings (OSTI)

The dynamic voltage restorer (DVR) is a custom device that is used to maintain the voltage at the load terminals from various power quality problems from a disturbed incoming supply. In this paper, a novel control strategy is described for mitigation ... Keywords: custom device, dynamic voltage restorer (DVR), power quality, sags, sensitive loads, swells

Rosli Omar; Nasrudin Abdul Rahim

2011-04-01T23:59:59.000Z

414

Currents' Physical Components (CPC) In Circuits with Nonsinusoidal Voltages and Currents  

E-Print Network (OSTI)

voltages and currents. It is true only for balanced loads supplied with a symmetrical voltage. However{ || || || || || || }P u u uY Y Y+ + . (20) The supply voltage is sinusoidal and symmetrical, thus RS ST TR R for energy permanent conversion in the load with power P. The remaining part of the supply current, i ­ ia

Czarnecki, Leszek S.

415

Energy Minimization Using Multiple Supply Voltages Jui-Ming Chang and Massoud Pedram  

E-Print Network (OSTI)

Energy Minimization Using Multiple Supply Voltages Jui-Ming Chang and Massoud Pedram Department and energy costs of these level shifters must be taken into account when comparing a multiple-supply voltage a dynamic programming technique for solv- ing the multiple supply voltage scheduling problem in both non

Pedram, Massoud

416

Charging-choke circuit with a crowbar for precision control of voltage  

DOE Patents (OSTI)

The operation of a circuit using a charging choke to obtain dc voltages is improved by constructing the circuit to be capable of producing a higher voltage than the desired value and crowbarring the charging choke when the load voltage reaches the desired value.

Praeg, W.F.

1975-11-25T23:59:59.000Z

417

Analysis the operation of DVR in voltage sag mitigation using EMTP  

Science Conference Proceedings (OSTI)

According to the reports, voltage sag is the most probable voltage problem in the network. As the number of sensitive loads increases rapidly the demand for a reliable and cost effective solution also has been increased. In this paper we are going to ... Keywords: DVR, custom power, distribution network, voltage sag

H. Monsef; B. Tamimi

2005-03-01T23:59:59.000Z

418

Voltage control of emerging distribution systems with induction motor loads using robust LQG approach  

E-Print Network (OSTI)

mode" in emerging distribution systems. The small-signal stability analysis indicates that load voltageVoltage control of emerging distribution systems with induction motor loads using robust LQG has significant performance to improve the voltage profile of the distributed generation system

Pota, Himanshu Roy

419

CMOS flash analog-to-digital converter for high speed and low voltage applications  

Science Conference Proceedings (OSTI)

A CMOS flash analog-to-digital converter (ADC) designed for high speed and low voltage is presented. Using the Threshold Inverter Quantization (TIQ) comparator technique, a flash ADC can be applied to low supply voltage. A fat tree encoder that has signal ... Keywords: TIQ comparator, analog-to-digital converter, fat tree encoder, flash ADC, high speed, low voltage

Jincheol Yoo; Kyusun Choi; Jahan Ghaznavi

2003-04-01T23:59:59.000Z

420

A model for the critical voltage for electrical degradation of GaN high electron mobility transistors  

E-Print Network (OSTI)

We have found that there is a critical drain-to-gate voltage beyond which GaN high-electron mobility transistors start to degrade in electrical-stress experiments. The critical voltage depends on the detailed voltage biasing ...

Joh, Jungwoo

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Dark current-voltage measurements on photovoltaic modules as a diagnostic or manufacturing tool  

DOE Green Energy (OSTI)

Dark current-voltage (dark I-V) measurements are commonly used to analyze the electrical characteristics of solar cells, providing an effective way to determine fundamental performance parameters without the need for a solar simulator. The dark I-V measurement procedure does not provide information regarding short-circuit current, but is more sensitive than light I-V measurements in determining the other parameters (series resistance, shunt resistance, diode factor, and diode saturation currents) that dictate the electrical performance of a photovoltaic device. The work documented here extends the use of dark I-V measurements to photovoltaic modules, illustrates their use in diagnosing module performance losses, and proposes their use for process monitoring during manufacturing.

King, D.L.; Hansen, B.R.; Quintana, M.A.; Kratochvil, J.A.

1997-10-01T23:59:59.000Z

422

Nuclear Maintenance Applications Center: Post-Trip Voltage Prediction at Nuclear and Other Generating Stations  

Science Conference Proceedings (OSTI)

The objective of this Electric Power Research Institute (EPRI) project is to investigate the possibility of predicting the switchyard voltage in a nuclear power plant (NPP) following a trip of a nuclear unit. Two methods of post-trip voltage prediction are investigated. The first method, called the V-Q method, uses minimal local plant information (such as unit operating conditionsactive and reactive power output and pre-trip voltage) to predict post-trip voltage based on the sensitivity of voltage to the...

2009-06-30T23:59:59.000Z

423

Voltage Node Arcing in the ICRH Antenna Vacuum Transmission Lines at JET  

Science Conference Proceedings (OSTI)

The observation of parasitic low-VSWR activity during operations of JET RF plant and the damage caused by arcing at the voltage-node in the vacuum transmission line (VTL) in 2004 highlight the importance of the problem of low-voltage breakdown in the ICRH systems. Simulations demonstrate little response of the RF circuit to the voltage-node arcing which explains why it remains largely unnoticed and complicates the design of protection systems. Analysis of the damage pattern produced by the voltage-node arcing suggests that multipactor-related phenomena occurring at elevated voltage thresholds in conditions of unfavorable VTL geometry are most plausible arc-provoking factors.

Monakhov, I.; Graham, M.; Mayoral, M.-L.; Nicholls, K.; Walden, A. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom); Bobkov, V. [Max-Planck Institut fuer Plasmaphysik, EURATOM Association, D-85748 Garching (Germany)

2007-09-28T23:59:59.000Z

424

Induction of nuclear fission by high-voltage application  

E-Print Network (OSTI)

In nuclear power generation, fissile materials are mainly used. For example, $U^{235}$ is fissile and therefore quite essential for use of nuclear energy. However, the material $U^{235}$ has very small natural abundance less than 1 %. We should seek possibility of utilizing fissionable materials such as $U^{238}$ because natural abundance of such fissionable materials is generally much larger than fissile ones. In this paper, we show that thermal neutrons with vanishing kinetic energy can induce nuclear fission when high voltage is applied to fissionable materials. To obtain this result, we use the liquid-drop model for nuclei. Finally, we propose how fissionable materials can be utilized.

Hirokazu Maruyama

2007-11-20T23:59:59.000Z

425

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

1998-01-01T23:59:59.000Z

426

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

Druce, R.L.; Kirbie, H.C.; Newton, M.A.

1998-06-30T23:59:59.000Z

427

Light-induced voltage alteration for integrated circuit analysis  

DOE Patents (OSTI)

An apparatus and method are described for analyzing an integrated circuit (IC), The invention uses a focused light beam that is scanned over a surface of the IC to generate a light-induced voltage alteration (LIVA) signal for analysis of the IC, The LIVA signal may be used to generate an image of the IC showing the location of any defects in the IC; and it may be further used to image and control the logic states of the IC. The invention has uses for IC failure analysis, for the development of ICs, for production-line inspection of ICs, and for qualification of ICs.

Cole, Jr., Edward I. (Albuquerque, NM); Soden, Jerry M. (Placitas, NM)

1995-01-01T23:59:59.000Z

428

Self-monitoring high voltage transmission line suspension insulator  

DOE Patents (OSTI)

A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

Stemler, Gary E. (Vancouver, WA); Scott, Donald N. (Vancouver, WA)

1981-01-01T23:59:59.000Z

429

Worldwide reliability surveys of high voltage circuit breakers  

Science Conference Proceedings (OSTI)

This article reports on the results of two CIGRE 13.06 Working Group worldwide surveys of the reliability of high voltage circuit breakers, 63 kV and above. The first inquiry included 78,000 breaker-years of ``in service data`` from 102 utilities in 22 countries during the years 1974--1977 and included all interrupting technologies. The second inquiry included 70,708 breaker-years from 132 utilities in 22 countries for the years 1988--1991 and only included single-pressure SF6 breakers, because this is what most utilities are now buying. Thirty-one US utilities submitted data.

Heising, C.R.

1995-05-01T23:59:59.000Z

430

Outdoor PV Module Degradation of Current-Voltage Parameters: Preprint  

DOE Green Energy (OSTI)

Photovoltaic (PV) module degradation rate analysis quantifies the loss of PV power output over time and is useful for estimating the impact of degradation on the cost of energy. An understanding of the degradation of all current-voltage (I-V) parameters helps to determine the cause of the degradation and also gives useful information for the design of the system. This study reports on data collected from 12 distinct mono- and poly-crystalline modules deployed at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. Most modules investigated showed < 0.5%/year decrease in maximum power due to short-circuit current decline.

Smith, R. M.; Jordan, D. C.; Kurtz, S. R.

2012-04-01T23:59:59.000Z

431

High-Voltage Power Supply System for Laser Isotope Separation  

SciTech Connect

This report presents several concepts for Laser High-Voltage Power Supply (HVPS) Systems for a Laser Isotope Separation facility. Selection of equipments and their arrangement into operational systems is based on proven designs and on application concepts now being developed. This report has identified a number of alternative system arrangements and has provided preliminary cost estimates for each. The report includes a recommendation for follow-on studies that will further define the optimum Laser HVPS Systems. Brief descriptions are given of Modulator/Regulator circuit trade-offs, system control interfaces, and their impact on costs.

Ketaily, E.C.; Buckner, R.P.; Uhrik, R.L.

1979-06-26T23:59:59.000Z

432

High Voltage Direct Current Live Line and Insulator Testing  

Science Conference Proceedings (OSTI)

This report has two main parts. The focus of the first part is on live work in overhead high-voltage direct current (HVDC) lines operating above 100 kV dc. It does not address issues related to lines for electric transport that typically operate below 60 kV dc worldwide. In addition, this first part of the report is not a detailed treatise on live work but, rather, addresses the main issues related to dc live work. More detailed information on the general topic of live work can be found in the references...

2011-12-23T23:59:59.000Z

433

Development of static and simulation programs for voltage stability studies of bulk power system  

SciTech Connect

In the analysis and evaluation of voltage stability, it is necessary to accurately identify the stability margin at each load point under specific system configuration or power balance condition. Voltage stability margin can be basically identified by the multi-solution load flow calculation method. When predicted by this static analysis that voltage instability may occur, time domain simulation will be required which includes the models of various control equipments related with system voltage profile. To deal with this, the following two analytical computer codes shown below were developed. (1) Voltage stability static analysis computer code employing a new load flow calculation method. (2) Time domain long term simulation computer code for voltage stability. These computer codes can also calculate the voltage stability index at each load point which is based on the margin to the stability power limit at each load point. The practicality of these codes developed were verified by applying to the IEEE-118 test system.

Nagao, T.; Tanaka, K.; Takenaka, K. [Central Research Inst. of Electric Power Industry, Tokyo (Japan)

1997-02-01T23:59:59.000Z

434

An accurate continuous calibration system for high voltage current transformer  

SciTech Connect

A continuous calibration system for high voltage current transformers is presented in this paper. The sensor of this system is based on a kind of electronic instrument current transformer, which is a clamp-shape air core coil. This system uses an optical fiber transmission system for its signal transmission and power supply. Finally the digital integrator and fourth-order convolution window algorithm as error calculation methods are realized by the virtual instrument with a personal computer. It is found that this system can calibrate a high voltage current transformer while energized, which means avoiding a long calibrating period in the power system and the loss of power metering expense. At the same time, it has a wide dynamic range and frequency band, and it can achieve a high accuracy measurement in a complex electromagnetic field environment. The experimental results and the on-site operation results presented in the last part of the paper, prove that it can reach the 0.05 accuracy class and is easy to operate on site.

Tong Yue; Li Binhong [College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, Hubei Province (China)

2011-02-15T23:59:59.000Z

435

Commercialization of Medium Voltage HTS Triax TM Cable Systems  

SciTech Connect

The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

Knoll, David

2012-12-31T23:59:59.000Z

436

Miniature UV lamp excited by subnanosecond voltage pulses  

SciTech Connect

Energy, time, and spectral characteristics of emission of the second positive system of N{sub 2} molecules in gaseous nitrogen, Ar - N{sub 2} mixture, and air are investigated. An FPG-10 generator with voltage pulse FWHM of 200 and 400 ps and matched-load amplitudes of 14 and 6 kV, respectively, is used to excite gases. It is shown that excitation can be performed in two regimes using this generator. In the first regime a diffuse discharge is formed at atmospheric pressure, which opens ways to design miniature nanosecond UV lamps. A diffuse discharge is formed due to the generation of runaway electrons, with the aid of electrodes having a small radius of curvature and voltage pulses with a sharp leading edge. In the second regime an elevated average radiation power is obtained under excitation by a barrier discharge. However, the operating pressure is lower in this case, and the sizes of the emitting region and the UV pulse width significantly increase. (laser applications and other topics in quantum electronics)

Erofeev, M V; Baksht, E Kh; Tarasenko, Viktor F; Shut'ko, Yu V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2010-08-27T23:59:59.000Z

437

Bi-directional power control system for voltage converter  

DOE Patents (OSTI)

A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

Garrigan, Neil Richard (Niskayuna, NY); King, Robert Dean (Schenectady, NY); Schwartz, James Edward (Slingerlands, NY)

1999-01-01T23:59:59.000Z

438

Bi-directional power control system for voltage converter  

DOE Patents (OSTI)

A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals. 10 figs.

Garrigan, N.R.; King, R.D.; Schwartz, J.E.

1999-05-11T23:59:59.000Z

439

DSP Based Ultracapacitor System for Hybrid-Electric Vehicles Juan W. Dixon  

E-Print Network (OSTI)

sources like fuel-cells, microturbines, zinc-air batteries or other supply unable to recover energy from bank are: nominal voltage: 300 Vdc; nominal current: 200 Adc; capacitance: 20 Farads. The amount of energy stored allows delivering 40 kW of power during 20 seconds, which is enough to accelerate

Rudnick, Hugh

440

Experiment and Simulation of Dynamic Voltage Regulation in Multiple Distributed Energy Resources Systems  

Science Conference Proceedings (OSTI)

Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction between the DEs is studied. The simulation results show the relationship between the voltages in the system and the reactive power required for the voltage regulation. Also, integrated voltage regulation (multiple DEs performing voltage regulation) can increase the voltage regulation capability of DEs and reduce the capital and operating costs.

Xu, Yan [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL; Rizy, D Tom [ORNL

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Pete_Lyons_Nomination_Testimony  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Peter B. Lyons Peter B. Lyons Assistant Secretary for Nuclear Energy Designee Before the Committee on Energy and Natural Resources United States Senate March 8, 2011 Chairman Bingaman, Ranking Member Murkowski, and distinguished Members of the Committee, it is an honor and a privilege to appear before you today as President Obama's nominee for Assistant Secretary for Nuclear Energy within the Department of Energy. It is a special honor for me to appear before this Committee. I worked with the Members and staff of this Committee for eight years while I was in Senator Domenici's personal office, and later when I served on the staff of this Committee. I originally came to the Senate on a detail from Los Alamos National Laboratory, where I worked for nearly 30 years.

442

Keys, nominals, and concrete domains  

Science Conference Proceedings (OSTI)

Many description logics (DLs) combine knowledge representation on an abstract, logical level with an interface to "concrete" domains like numbers and strings with built-in predicates such as <, +, and prefix-of. These hybrid DLs have turned out to ...

Carsten Lutz; Carlos Areces; Ian Horrocks; Ulrike Sattler

2005-01-01T23:59:59.000Z

443

Champions Nomination | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Description Organization Type * Industry Non-profit Association Academic Institution Market Sector * Apparel Building Materials Food Concessions Furniture Information...

444

Electrochemical and rate performance study of high-voltage lithium-richcomposition: Li1.2Mn0.525Ni0.175Co0.1O2  

Science Conference Proceedings (OSTI)

We report electrochemical studies of high voltage cathodes composed of lithium rich layeredlayered material having the nominal composition Li1.2Mn0.525Ni0.175Co0.1O2, or equivalently 0.6Li[Li1/3Mn2/3]O2 0.4Li[Mn0.3Ni0.45Co0.25]O2. These aspects were investigated by cyclic voltammetry studies in conjunction with electrochemical impedance spectroscopy measurements to understand the redox reactions involving multiple transition metals and their capacity contribution at higher voltages, up to 4.9 V. Further, cathodes with 1.5 wt.% carbon nanofibers added to the Li1.2Mn0.525Ni0.175Co0.1O2 composite electrode showed stable reversible capacities of about 280 mAh g 1 when cycled to 4.9 V for more than 100 cycles, and almost a factor of two improvements in the rate performance compared to the electrode composition prepared using conventional composition (7.5% carbon black and 7.5% binder).

Martha, Surendra K [ORNL; Nanda, Jagjit [ORNL; Veith, Gabriel M [ORNL; Dudney, Nancy J [ORNL

2012-01-01T23:59:59.000Z

445

DECENTRALIZED CONTROL ARCHITECTURE FOR COUPLING MICROGRIDS INTO DISTRIBUTION NETWORKS 1 Task 1: Coupling Low-Voltage Microgrids into  

E-Print Network (OSTI)

DECENTRALIZED CONTROL ARCHITECTURE FOR COUPLING MICROGRIDS INTO DISTRIBUTION NETWORKS 1 Task 1: Coupling Low-Voltage Microgrids into Mid-Voltage Distribution Systems Zhao Wang, Student Member, IEEE-voltage (LV) microgrids. At the same time, reactive power is dispatched coordinatively so that voltage

Lemmon, Michael

446

System and method for floating-substrate passive voltage contrast  

DOE Patents (OSTI)

A passive voltage contrast (PVC) system and method are disclosed for analyzing ICs to locate defects and failure mechanisms. During analysis a device side of a semiconductor die containing the IC is maintained in an electrically-floating condition without any ground electrical connection while a charged particle beam is scanned over the device side. Secondary particle emission from the device side of the IC is detected to form an image of device features, including electrical vias connected to transistor gates or to other structures in the IC. A difference in image contrast allows the defects or failure mechanisms be pinpointed. Varying the scan rate can, in some instances, produce an image reversal to facilitate precisely locating the defects or failure mechanisms in the IC. The system and method are useful for failure analysis of ICs formed on substrates (e.g. bulk semiconductor substrates and SOI substrates) and other types of structures.

Jenkins, Mark W. (Albuquerque, NM); Cole, Jr., Edward I. (Albuquerque, NM); Tangyunyong, Paiboon (Albuquerque, NM); Soden, Jerry M. (Placitas, NM); Walraven, Jeremy A. (Albuquerque, NM); Pimentel, Alejandro A. (Albuquerque, NM)

2009-04-28T23:59:59.000Z

447

High-voltage atmospheric breakdown across intervening rutile dielectrics.  

SciTech Connect

This report documents work conducted in FY13 on electrical discharge experiments performed to develop predictive computational models of the fundamental processes of surface breakdown in the vicinity of high-permittivity material interfaces. Further, experiments were conducted to determine if free carrier electrons could be excited into the conduction band thus lowering the effective breakdown voltage when UV photons (4.66 eV) from a high energy pulsed laser were incident on the rutile sample. This report documents the numerical approach, the experimental setup, and summarizes the data and simulations. Lastly, it describes the path forward and challenges that must be overcome in order to improve future experiments for characterizing the breakdown behavior for rutile.

Williamson, Kenneth Martin; Simpson, Sean; Coats, Rebecca Sue; Jorgenson, Roy Eberhardt; Hjalmarson, Harold Paul; Pasik, Michael Francis

2013-09-01T23:59:59.000Z

448

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents (OSTI)

A process for fabricating sequential inductors and varistor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varistor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process. 6 figs.

Cooper, G.A.

1994-10-04T23:59:59.000Z

449

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents (OSTI)

A process for fabricating sequential inductors and varactor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varactor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process.

Cooper, Gregory A. (346 Primrose Dr., Pleasant Hill, CA 94523)

1994-01-01T23:59:59.000Z

450

Voltage spike detection in high field superconducting accelerator magnets  

SciTech Connect

A measurement system for the detection of small magnetic flux changes in superconducting magnets, which are due to either mechanical motion of the conductor or flux jump, has been developed at Fermilab. These flux changes are detected as small amplitude, short duration voltage spikes, which are {approx}15mV in magnitude and lasts for {approx}30 {micro}sec. The detection system combines an analog circuit for the signal conditioning of two coil segments and a fast data acquisition system for digitizing the results, performing threshold detection, and storing the resultant data. The design of the spike detection system along with the modeling results and noise analysis will be presented. Data from tests of high field Nb{sub 3}Sn magnets at currents up to {approx}20KA will also be shown.

Orris, D.F.; Carcagno, R.; Feher, S.; Makulski, A.; Pischalnikov, Y.M.; /Fermilab

2004-12-01T23:59:59.000Z

451

Voltage holding considerations for direct-collection units  

SciTech Connect

Results have been obtained from initial experiments designed to study high-voltage breakdown under conditions of importance to the design of direct- collection units. A coaxial configuration was used to mock-up critical fields near grid wires. With appropriate heat conditioning, fields as high as 9.6 x 10/ sup 5/ V/cm were maintained at the surface of a 7-mil-diam tungsten wire. This represents an enhanced field of ~10/sup 8/V/cm at whisker'' sites. Breakdown criteria are proposed for three regimes; initial, field-emission, and ultimate, which differ by the amount of prior conditioning applied to the wire. Additional considerations of importance to direct collectors such as the effect of thermionic emission and ion bombardment are discussed. (auth)

Miley, G.H.

1973-12-01T23:59:59.000Z

452

High voltage design structure for high temperature superconducting device  

DOE Patents (OSTI)

In accordance with the present invention, modular corona shields are employed in a HTS device to reduce the electric field surrounding the HTS device. In a exemplary embodiment a fault current limiter module in the insulation region of a cryogenic cooling system has at least one fault current limiter set which employs a first corona shield disposed along the top portion of the fault current limiter set and is electrically coupled to the fault current limiter set. A second corona shield is disposed along the bottom portion of the fault current limiter set and is electrically coupled to the fault current limiter set. An insulation barrier is disposed within the insulation region along at least one side of the fault current limiter set. The first corona shield and the second corona shield act together to reduce the electric field surrounding the fault limiter set when voltage is applied to the fault limiter set.

Tekletsadik, Kasegn D. (Rexford, NY)

2008-05-20T23:59:59.000Z

453

Curing system for high voltage cross linked cables  

DOE Patents (OSTI)

This invention makes extruded, vulcanized, high voltage cables insulated with thermosetting compounds at much higher rates of production and with superior insulation of reduced thickness and with reduced cavities or voids in the insulation. As the cable comes from an extruder, it passes into a curing chamber with a heat booster that quickly raises the insulation to a temperature at which it is cured much more quickly than with steam heating of the prior art. A high temperature liquid in contact with the insulation maintains the high temperature; and because of the greater curing heat, the cable can travel through the curing chamber at a faster rate and into a cooling tube where it contacts with a cooling liquid under high pressure. The insulation compound is treated to reduce the size of cavities; and the high pressure maintained by the curing and cooling mediums prevent expansion of cavities before the insulation is set.

Bahder, George (Edison, NJ); Katz, Carlos (Edison, NJ); Bopp, Louis A. (Fair Haven, NJ)

1978-01-01T23:59:59.000Z

454

Sacramento Area Voltage Support Draft Environmental Impact Statement  

Science Conference Proceedings (OSTI)

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the ''National Environmental Policy Act'' (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2002-11-15T23:59:59.000Z

455

Sacramento Area Voltage Support Final Environmental Impact Statement  

Science Conference Proceedings (OSTI)

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the National Environmental Policy Act (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: (1) Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; (2) Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and (3) Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2003-09-19T23:59:59.000Z

456

Pulsed voltage electrospray ion source and method for preventing analyte electrolysis  

SciTech Connect

An electrospray ion source and method of operation includes the application of pulsed voltage to prevent electrolysis of analytes with a low electrochemical potential. The electrospray ion source can include an emitter, a counter electrode, and a power supply. The emitter can include a liquid conduit, a primary working electrode having a liquid contacting surface, and a spray tip, where the liquid conduit and the working electrode are in liquid communication. The counter electrode can be proximate to, but separated from, the spray tip. The power system can supply voltage to the working electrode in the form of a pulse wave, where the pulse wave oscillates between at least an energized voltage and a relaxation voltage. The relaxation duration of the relaxation voltage can range from 1 millisecond to 35 milliseconds. The pulse duration of the energized voltage can be less than 1 millisecond and the frequency of the pulse wave can range from 30 to 800 Hz.

Kertesz, Vilmos (Knoxville, TN); Van Berkel, Gary (Clinton, TN)

2011-12-27T23:59:59.000Z

457

Turbine-Generator Topics for Power Plant Engineers: Synchronous Generator Voltage Regulator Basics  

Science Conference Proceedings (OSTI)

This material is intended for the new engineer, the control room operator, management, or the non-engineer. The basics of a synchronous generator excitation system; the fundamentals of the voltage regulator; and its controls and functions are discussed. The typical exciter types are covered, but not in detail. There is also basic information on voltage regulator maintenance issues. Put simply, the excitation system is made up of three basic component systems. The voltage regulator monitors the synchronou...

2012-02-16T23:59:59.000Z

458

Assessment and Evaluation of Next Generation High-Voltage DC Technologies—Phase 2  

Science Conference Proceedings (OSTI)

As an established technology for bulk power transmission, high-voltage direct current (HVDC) power transmission is being used worldwide, and more than 100 schemes are operating at present. Advances in voltage sourced converter (VSC) technologies and power electronic devices with use of insulated-gate bipolar transistors (IGBTs) will provide improved system performance and reliability. Also, the present highest operating voltage is +/- 800 kV as China and India are building +/- 800-kV lines. Anticipating ...

2009-12-17T23:59:59.000Z

459

Technology Assessment and Application Guide for a Capacitor-Based Voltage Sag Compensator  

Science Conference Proceedings (OSTI)

Voltage sags and momentary interruptions result in a significant amount of process shutdowns for industrial customers. Voltage sag compensation devices help mitigate sags for susceptible devices and components, allowing for more reliable and robust process performance. This report provides a technology assessment and application guide for Marathon Power's Voltage Sag Compensator, a 120-V, 750-VA unit designed to provide AC backup power to sensitive electronic loads.

2009-12-22T23:59:59.000Z

460

ETTM: Low Voltage System Protection and Coordination Computer-Based Training Version 1.0  

Science Conference Proceedings (OSTI)

ETTM Low Voltage System Protection and Coordination is a computer-based training module that allows users to access training when desired and review it at their own pace. It provides graphics and limited interactive features to enhance learning. Low voltage power systems are generally classified as AC power systems operating at the 120 600 Volt level. Because they often serve a large number of diverse loads in residences, businesses, and power plants, low voltage power systems present a unique set of cha...

2010-11-30T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Voltage-Matched, Monolithic, Multi-Band-Gap Devices  

DOE Patents (OSTI)

Monolithic, tandem, photonic cells include at least a first semiconductor layer and a second semiconductor layer, wherein each semiconductor layer includes an n-type region, a p-type region, and a given band-gap energy. Formed within each semiconductor layer is a string of electrically connected photonic sub-cells. By carefully selecting the numbers of photonic sub-cells in the first and second layer photonic sub-cell string(s), and by carefully selecting the manner in which the sub-cells in a first and second layer photonic sub-cell string(s) are electrically connected, each of the first and second layer sub-cell strings may be made to achieve one or more substantially identical electrical characteristics.

Wanlass, M. W.; Mascarenhas, A.

2006-08-22T23:59:59.000Z

462

Unlikely Combination of Experiments with a Novel High-Voltage CIGS Photovoltaic Array (Presentation)  

DOE Green Energy (OSTI)

The goals of this study are to: (1) parameterize current-voltage (I-V) performance over a wide range of illumination and temperatures: (a) 50-1150 W/m{sup 2} irradiance, 5-65 C; (b) obtain array temperature coefficients; and (c) quantify energy production; (2) investigate high-voltage leakage currents from the CIS modules in a high-voltage array: determine dependence on moisture, temperature, and voltage bias and ascertain corrosion problems if any; and (3) study long-term power and energy production stability.

del Cueto, J. A.; Sekulic, B. R.

2006-05-01T23:59:59.000Z

463

Phase-Field Simulations of a Simple Voltage-Controlled Magnetic ...  

Science Conference Proceedings (OSTI)

The voltage-induced magnetization and/or magnetic domain switching dynamics in ... Our results offer a promising new way towards future high-performance ...

464

Effect of Voltage Pulse Duration on Surface Properties of Micro Arc ...  

Science Conference Proceedings (OSTI)

Durations of successive positive and negative voltage pulses in one cycle ... Electrodeposition of Ni-Al-Cr Bond Coat and Its High Temperature Behavior on ...

465

High voltage bus and auxiliary heater control system for an electric or hybrid vehicle  

DOE Green Energy (OSTI)

A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

Murty, Balarama Vempaty (West Bloomfield, MI)

2000-01-01T23:59:59.000Z

466

Theory and practice of dynamic voltage/frequency scaling in the high performance computing environment.  

E-Print Network (OSTI)

?? This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We… (more)

Rountree, Barry Louis

2010-01-01T23:59:59.000Z

467

Theory and Practice of Dynamic Voltage/Frequency Scaling in the High Performance Computing Environment .  

E-Print Network (OSTI)

??This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We summarize… (more)

Rountree, Barry

2009-01-01T23:59:59.000Z

468

Summary of transient high-voltage calculations for the FRX-C experiment  

Science Conference Proceedings (OSTI)

Calculations of the electrical circuit equations are performed over a wide range of parameters corresponding to the FRX-C field-reversed THETA-pinch experiment at Los Alamos. Without any plasma or external damping, serious voltage doubling and quadrupling of the main capacitor bank charge voltage are observed. These oscillating high voltages are found to be adequately suppressed by the strategic placement of external snubber circuitry. On the other hand, no doubling of the THETA-pinch preionization bank charge voltage is found. Calculations of the equations for the z-pinch preionization circuit are also performed.

Kewish, R.W. Jr.; Rej, D.J.

1982-06-01T23:59:59.000Z

469

The dynamics of electricity demand and supply in the low voltage distribution grid: a model study:.  

E-Print Network (OSTI)

??In this thesis a simulation study is executed that analyses how new developments of household electricity demand and decentralised electricity generation affect the low voltage… (more)

Van Zoest, P.L.A.

2013-01-01T23:59:59.000Z

470

Radio-Frequency Interference (RFI) From Extra-High- Voltage (EHV) Transmission Lines  

E-Print Network (OSTI)

The subject of radio-frequency interference (RFI) generated by high-voltage transmission lines has long been of both academic and commercial interest because of concerns about

Patrick C. Crane

2010-01-01T23:59:59.000Z

471

Measurement-based Voltage Stability Margin Calculator (MVSMC) v1.0  

Science Conference Proceedings (OSTI)

Voltage stability is a major concern in daily power system operations and a leading factor to limit power transfers in a prevailing open access environment. Voltage instability usually starts from a local bus or area, and then may evolve into a wide-area instability problem if it cannot be controlled locally. This program utilizes EPRImeasurement-based voltage stability monitoring technology and is able to calculate voltage stability margin indices at a load bus or for an entire load area using the measu...

2009-10-30T23:59:59.000Z

472

Triple-Voltage DC-DC Converter - Oak Ridge National Laboratory  

Overall Project Objective ... –Saving in the switch and gate drive component count increases ... power transfer between the low-voltage buses and the high

473

Development of improved iron Fischer-Tropsch catalysts. [Iron catalyst with nominal composition 100Fe/0. 3Cu/0. 8K  

SciTech Connect

Three tests (two fixed bed and one stirred tank slurry reactor) were completed during the reporting period. Also, the work on catalyst characterization by different techniques (atomic absorption, BET surface area and pore size distribution and x-ray powder diffraction).The performance of a precipitated iron catalyst with nominal composition lOOFe/0.3Cu/0.8K has been evaluated in two fixed bed reactor tests designated FB-0142 and FB-0352 following pretreatment with syngas (H{sub 2}/CO=0.67) at 280{degree}C, 3Nl/g-cat/h and atomspheric pressure for 8 hours. Flow interruption occurred in the first test (FB-0142) at about 72h on stream, and the second test (FB-0352) was to assess any potential adverse effects of this flow interruption on performance of the catalyst. The catalyst was tested at 250{degree}C, 200 psig, 2Nl/g-cat/h using syngas of the same composition as that employed during the pretreatment. Initial conversions in both tests were high (about 84%) but the catalyst deactivated fairly rapidly. The (H{sub 2} + CO) conversion at the end of the first test (120h on stream) was about 52%, whereas the syngas conversion at the end of the second test (150h) was about 55%, indicating that the brief flow interruption during test FB-0142 had resulted in higher deactivation rate. Hydrocarbon selectivities in both tests were similar and their average values werr: (CH{sub 4})=4.7, (C{sub 2}{minus}C{sub 4})=19.5, (C{sub 5}{minus}C{sub 11})=25.3 and C{sub 12}{sup +}=50.5 wt%.

Bukur, D.B.

1992-04-24T23:59:59.000Z

474

Characterization of the Li(Si)/CoS(2) couple for a high-voltage, high-power thermal battery  

DOE Green Energy (OSTI)

In order to determined the capabilities of a thermal battery with high-voltage and high-power requirements, a detailed characterization of the candidate LiSi/LiCl-LiBr-LiF/CoS{sub 2} electrochemical couple was conducted. The rate capability of this system was investigated using 0.75 inch-dia. and 1.25 inch-dia. single and multiple cells under isothermal conditions, where the cells were regularly pulsed at increasingly higher currents. Limitations of the electronic loads and power supplies necessitated using batteries to obtain the desired maximum current densities possible for this system. Both 1.25 inch-dia. and 3 inch-dia. stacks were used with the number of cells ranging from 5 to 20. Initial tests involved 1.25 inch-dia. cells, where current densities in excess of 15 A/cm{sup 2} (>200 W/cm{sup 2}) were attained with 20-cell batteries during 1-s pulses. In subsequent follow-up tests with 3 inch-dia., 10-cell batteries, ten 400-A 1-s pulses were delivered over an operating period often minutes. These tests formed the foundation for subsequent full-sized battery tests with 125 cells with this chemistry.

GUIDOTTI,RONALD A.; REINHARDT,FREDERICK W.

2000-02-01T23:59:59.000Z

475

High voltage power supply with modular series resonant inverters  

DOE Patents (OSTI)

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

Dreifuerst, Gary R. (Livermore, CA); Merritt, Bernard T. (Livermore, CA)

1995-01-01T23:59:59.000Z

476

High voltage power supply with modular series resonant inverters  

DOE Patents (OSTI)

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.

Dreifuerst, G.R.; Merritt, B.T.

1995-07-18T23:59:59.000Z

477

Life testing of a low voltage air circuit breaker  

Science Conference Proceedings (OSTI)

A DS-416 low voltage air circuit breaker manufactured by Westinghouse was mechanically cycled to identify age-related degradation in the various breaker subcomponents, specifically the power-operated mechanism. This accelerated aging test was performed on one breaker unit for over 36,000 cycles. Three separate pole shafts, one with a 60-degree weld, one with a 120-degree weld, and one with a 180-degree weld in the third pole lever were used to characterize cracking in the welds. In addition, during the testing three different operating mechanisms and several other parts were replaced as they became inoperable. Among the seven welds on the pole shaft, {number_sign}1 and {number_sign}3 were found to be critical ones whose fracture can result in misalignment of the pole levers. This can lead to problems with the operating mechanism, including the burning of coils, excessive wear in certain parts, and overstressed linkages. Furthermore, the limiting service life of a number of subcomponents of the power-operated mechanism, including the operating mechanism itself, were assessed. Based on these findings, suggestions are provided to alleviate the age-related degradation that could occur as a result of normal closing and opening of the breaker contacts during its service life. Also, cause and effect analyses of various age-related degradation in various breaker parts are discussed.

Subudhi, M. [Brookhaven National Lab., Upton, NY (United States); Aggarwal, S. [Nuclear Regulatory Commission, Washington, DC (United States)

1992-06-01T23:59:59.000Z

478

Life testing of a low voltage air circuit breaker  

Science Conference Proceedings (OSTI)

A DS-416 low voltage air circuit breaker manufactured by Westinghouse was mechanically cycled to identify age-related degradation in the various breaker subcomponents, specifically the power-operated mechanism. This accelerated aging test was performed on one breaker unit for over 36,000 cycles. Three separate pole shafts, one with a 60-degree weld, one with a 120-degree weld, and one with a 180-degree weld in the third pole lever were used to characterize cracking in the welds. In addition, during the testing three different operating mechanisms and several other parts were replaced as they became inoperable. Among the seven welds on the pole shaft, {number sign}1 and {number sign}3 were found to be critical ones whose fracture can result in misalignment of the pole levers. This can lead to problems with the operating mechanism, including the burning of coils, excessive wear in certain parts, and overstressed linkages. Furthermore, the limiting service life of a number of subcomponents of the power-operated mechanism, including the operating mechanism itself, were assessed. Based on these findings, suggestions are provided to alleviate the age-related degradation that could occur as a result of normal closing and opening of the breaker contacts during its service life. Also, cause and effect analyses of various age-related degradation in various breaker parts are discussed.

Subudhi, M. (Brookhaven National Lab., Upton, NY (United States)); Aggarwal, S. (Nuclear Regulatory Commission, Washington, DC (United States))

1992-01-01T23:59:59.000Z

479

Circuit for monitoring temperature of high-voltage equipment  

DOE Patents (OSTI)

This invention relates to an improved circuit for measuring temperature in a region at high electric potential and generating a read-out of the same in a region at lower potential. The circuit is specially designed to combine high sensitivity, stability, and accuracy. A major portion of the circuit situated in the high-potential region can take the form of an integrated circuit. The preferred form of the circuit includes an input section which is situated in the high-potential region and comprises a temperature-compensated thermocouple circuit for sensing temperature, an oscillator circuit for generating a train of ramp voltages whose rise time varies inversely with the thermocouple output, a comparator and switching circuit for converting the oscillator output to pulses whose frequency is proportional to the thermocouple output, and a light-emitting diode which is energized by these pulses. An optical coupling transmits the light pulses generated by the diode to an output section of the circuit, situated in a region at ground. The output section comprises means for converting the transmitted pulses to electrical pulses of corresponding frequency, means for amplifying the electrical pulses, and means for displaying the frequency of the same. The preferred embodiment of the overall circuit is designed so that the frequency of the output signal in hertz and tenths of hertz is equal to the sensed temperature in degrees and tenths of degrees.

Jacobs, Martin E. (Chillicothe, OH)

1976-01-01T23:59:59.000Z

480

PRESENT AND FUTURE TECHNOLOGY OF HIGH VOLTAGE SYSTEMS FOR NEUTRAL BEAM INJECTORS  

E-Print Network (OSTI)

the accel voltage reg­ ulation requirement could be relaxedVOLTAGE SWITCHES TUBES SCR ASSEMBLIES CROSSED-FIELD INTERRUPTERS MAGNETIC CORE ARC SNUEBER3 COMPUTERS FOR CONTROL AND DIAGNOSTICS OPERATIONAL REQUIREMENTSvoltage- regulated (flat-topped) to 1%. If good regulation Is not a prime requirement,

Baker, W.R.

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Voltage-tunable singlet-triplet transition in lateral quantum dots  

E-Print Network (OSTI)

Results of calculations and high source-drain transport measurements are presented which demonstrate voltage-tunable entanglement of electron pairs in lateral quantum dots. At a fixed magnetic field, the application of a judiciously-chosen gate voltage alters the ground-state of an electron pair from an entagled spin singlet to a spin triplet.

Jordan Kyriakidis; M. Pioro-Ladriere; M. Ciorga; A. S. Sachrajda; P. Hawrylak

2001-11-28T23:59:59.000Z

482

Simulation for Performance Analysis of Grid-Connected Induction Generators with Input Voltage Control  

Science Conference Proceedings (OSTI)

With the increasing application of wind energy, various technologies are developed for analyzing the performance of grid-connected induction generator (GIG) based wind energy conversion systems (WECSs). Input voltage control is one among them. In the ... Keywords: grid-connected induction generators (GIGs), wind energy conversion systems (WECSs), input voltage control, performance analysis, MATLAB

Farhad Ilahi Bakhsh, Shirazul Islam, Sayeed Ahmad

2013-04-01T23:59:59.000Z

483

Modeling considerations in static and dynamic voltage stability studies of shipboard power systems  

Science Conference Proceedings (OSTI)

Better modeling is a key issue to system analysis and emulating real system performances accurately. This paper addresses modeling considerations and approaches to be taken for voltage stability analysis. Two approaches, static and dynamic analysis, ... Keywords: PSCAD, dynamic analysis, numerical integration method, static analysis, voltage stability

Minglan Lin; Anurag K. Srivastava; Noel N. Schulz

2007-07-01T23:59:59.000Z

484

A New Thermal-Conscious System-Level Methodology for Energy-Efficient Processor Voltage Selection  

E-Print Network (OSTI)

A New Thermal-Conscious System-Level Methodology for Energy-Efficient Processor Voltage Selection a thermal-conscious system-level methodology to make energy-efficient voltage selection (VS) for nanometer), thermal resistance, are integrated and considered in our system models, and their impacts on energy

Wang, Yu

485

Energy-efficient datapath scheduling using multiple voltages and dynamic clocking  

Science Conference Proceedings (OSTI)

Recently, dynamic frequency scaling has been explored at the CPU and system levels for power optimization. Low-power datapath scheduling using multiple supply voltages has been well researched. In this work, we develop new datapath scheduling algorithms ... Keywords: High-level synthesis, dynamic frequency clocking, low-power datapath synthesis, multiple voltage scheduling, resource-constrained scheduling, time-constrained scheduling

Saraju P. Mohanty; N. Ranganathan

2005-04-01T23:59:59.000Z

486

Analysis and Mitigation of Balanced Voltage Sag with the Help of Energy Storage System  

Science Conference Proceedings (OSTI)

Voltage sag is one of the major power quality problem which results in a failure or a mis-operation of end use equipments. Sensitive industrial loads and Utility distribution networks all suffer from various types of outages and service interruptions ... Keywords: Power quality, voltage sag, Custom power Devices, DVR, Energy Storage System, pulse width modulation

D. N. Katole; K. D. Joshi

2010-11-01T23:59:59.000Z

487

Steady-state power flow modeling for a dynamic voltage restorer  

Science Conference Proceedings (OSTI)

This paper presents analysis, modeling and simulation of power distribution network performance incorporating with an installed dynamic voltage restorer (DVR). DVR is one of series compensators used in power distribution systems in order to maintain ... Keywords: Gauss-Seidel method, dynamic voltage restorer, modeling, power flow, simulation

T. Ratniyomchai; T. Kulworawanichpong

2006-03-01T23:59:59.000Z

488

Extraction of voltage harmonics using multi-layer perceptron neural network  

Science Conference Proceedings (OSTI)

This paper presents a harmonic extraction algorithm using artificial neural networks for Dynamic Voltage Restorers (DVRs). The suggested algorithm employs a feed forward Multi Layer Perceptron (MLP) Neural Network with error back propagation learning ... Keywords: Dynamic Voltage Restorer, Harmonic extraction, Multi Layer Perceptron, Neural Networks

Mehmet Tümay; M. Emin Meral; K. Ça?atay Bayindir

2008-09-01T23:59:59.000Z

489

Analysis of Low Voltage Ride through Capability in Wind Turbine Based on DFIG  

Science Conference Proceedings (OSTI)

In this paper the coordination of the low voltage ride through capability and the crowbar protection of DFIG are discussed. Different protection strategies for over-current and low voltage protection are presented. Effect of different short-circuit impedance, ... Keywords: doubly fed induction generator (DFIG), low voltges ride through (LVRT), crowbar protection

Shan-Ying Li; Yu Sun; Tao Wu; Yu-Zhi Liang; Xiao Yu; Jian-Ming Zhang

2010-06-01T23:59:59.000Z

490

The Influence of Electrical Parameters of Double Fed Induction Generator on the Transient Voltage Stability  

Science Conference Proceedings (OSTI)

This paper describes the effect of electrical parameters of the double fed induction generator on the transient voltage stability of a DFIG to a simple grid; the DFIG model has been developed in the Matlab/simulink tool. The dynamic behavior of a wind ... Keywords: DFIG model, electrical parameter, voltage stability, small signal analysis

Hongmei Li; Qiulan Wan; Zhaoxing Ma

2010-06-01T23:59:59.000Z

491

Research on the Control Strategy of Low Voltage Ride-Through for Doubly Fed Induction Generator  

Science Conference Proceedings (OSTI)

With the development of modern wind energy generation, higher requirements to the grid in case of a failure were raised. In order to faciliate the recovery of power, while voltage dips in a certain range, protecting the rotor side converter and providing ... Keywords: Wind energy generation, Doubly fed generator, Voltage sag, Dynamic response analysis

Zhang Jianhua; Wang Jian; Mo Yueping; Xin Fulong

2011-02-01T23:59:59.000Z

492

Study on Control Strategy for DFIG-Based Wind Turbines Under Unbalanced Grid Voltages  

Science Conference Proceedings (OSTI)

Unbalanced input voltages would make doubly fed induction generator (DFIG)-based wind turbine operating performance deteriorate, such as shaft tremble, temperature increasing, and so on, even make it cut out of the power grid. Meanwhile, without proper ... Keywords: DFIG, dual current control, unbalanced input voltages

Changxi Huang, Shuying Yang, Xing Zhang, Zhen Xie

2012-07-01T23:59:59.000Z

493

Study on the operation of a low-voltage AC microgrid with multiple distributed generations  

Science Conference Proceedings (OSTI)

This paper aims to study the operation of a grid-connected low-voltage AC microgrid with multiple distributed generations (DGs). First of all, a 400 V low-voltage AC microgrid integrated with a 30 kW microturbine generator, a 13 kW photovoltaic generation ... Keywords: distributed generators, distribution systems, microgrids, steady-state analysis, three-phase power flow

Wei-Tzer Huang

2010-12-01T23:59:59.000Z

494

Energy Aware Dynamic Voltage and Frequency Selection for Real-Time Systems with Energy Harvesting  

E-Print Network (OSTI)

Energy Aware Dynamic Voltage and Frequency Selection for Real-Time Systems with Energy Harvesting}@binghamton.edu Abstract In this paper, an energy aware dynamic voltage and frequency selection (EA-DVFS) algorithm energy and the harvested energy in a future duration. Specifically, if the system has sufficient energy

Qiu, Qinru

495

Current status of CMOS low voltage and low power wireless IC designs  

Science Conference Proceedings (OSTI)

This paper surveys recent research on CMOS low voltage and low power IC designs for wireless applications. Advancements and challenges in using nanometer IC processes are addressed, and the impacts of device scaling on wireless systems are discussed. ... Keywords: CMOS, Integrated Circuits (IC), Low-Power, Low-Voltage, Nanometer, Radio Frequency (RF), Sub-1V, Wireless

Tommy K. Tsang; Mourad N. El-Gamal; Krzysztof Iniewski; Kenneth A. Townsend; James W. Haslett; Yanjie Wang

2007-10-01T23:59:59.000Z

496

Chiller Shutdowns Caused by Sensitivity of Control Relays to Voltage Sags  

Science Conference Proceedings (OSTI)

This document presents the investigation performed by the EPRI Power Electronics Applications Center (PEAC) and Potomac Electric Power Company (PEPCO) of chiller shutdowns which coincided with momentary reduced voltage or voltage sags at the National Archives II, a U.S. government research and storage facility that houses many of our national treasures.

2003-12-31T23:59:59.000Z

497

Investigating the electric power distribution system (EPDS) bus voltage in the presence of distributed generation (DG)  

Science Conference Proceedings (OSTI)

This paper investigates the Electric Power Distribution System (EPDS) bus voltage in the presence of Distributed Generation (DG). Distribution Company's (Discos) planner endeavor to develop new planning strategies for their network in order to serve ... Keywords: PSCAD, distributed generation, electric power distribution system, islanding, power quality, voltage stability

Hasham Khan; Mohammad Ahmad Choudhry; Tahir Mahmood; Aamir Hanif

2006-04-01T23:59:59.000Z

498

FPGA Implementation of Space Vector PWM Technique for Voltage Source Inverter Fed Induction Motor Drive  

Science Conference Proceedings (OSTI)

This paper presents implementation of Space Vector Pulse Width Modulation (SVPWM) technique for three phase Voltage Source Inverter (VSI) using Field Programmable Gate Array (FPGA). Variable voltage and frequency supply to ac drives is invariably obtained ... Keywords: VSI, SVPWM, FPGA, Induction Motor

R. Rajendran; N. Devarajan

2009-12-01T23:59:59.000Z

499

A Smart Grid Voltage Sag Detector using an EEMD-Based Approach  

E-Print Network (OSTI)

A Smart Grid Voltage Sag Detector using an EEMD-Based Approach Yassine Amirat, Member, IEEE and Mohamed Benbouzid, Senior Member, IEEE Abstract--Smart grids have become a focal point in renewable energy detection in smart grids. Index Terms--Smart grid, voltage sag detection, power quality (PQ), ensemble

Brest, Université de