Powered by Deep Web Technologies
Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Property:Nominal Voltage | Open Energy Information  

Open Energy Info (EERE)

Nominal Voltage Nominal Voltage Jump to: navigation, search Property Name Nominal Voltage Property Type Number This is a property of type Number. Pages using the property "Nominal Voltage" Showing 22 pages using this property. D Distributed Generation Study/10 West 66th Street Corp + 480 + Distributed Generation Study/615 kW Waukesha Packaged System + 480 + Distributed Generation Study/Aisin Seiki G60 at Hooligans Bar and Grille + 240 + Distributed Generation Study/Arrow Linen + 480 + Distributed Generation Study/Dakota Station (Minnegasco) + 0 + Distributed Generation Study/Elgin Community College + 4,160 + Distributed Generation Study/Emerling Farm + 480 + Distributed Generation Study/Floyd Bennett + 480 + Distributed Generation Study/Harbec Plastics + 480 +

2

Design & Fabrication of a High-Voltage Photovoltaic Cell  

SciTech Connect

Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

Felder, Jennifer; /North Carolina State U. /SLAC

2012-09-05T23:59:59.000Z

3

Modeling the operating voltage of liquid metal battery cells  

E-Print Network (OSTI)

A one-dimensional, integrative model of the voltage during liquid metal battery operation has been developed to enhance the understanding of performance at the cell level. Two liquid metal batteries were studied: Mg-Sb for ...

Newhouse, Jocelyn Marie

2014-01-01T23:59:59.000Z

4

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided into high voltage  

E-Print Network (OSTI)

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided than one subtype of channel. A new subfamily of voltage-dependent calcium channel á1 subunit genes. 1999), having four domains, each with a voltage sensor and a pore-forming P loop. However

Dolphin, Annette C.

5

Fuel Cell Technology Status - Voltage Degradation (Presentation)  

SciTech Connect

This presentation describes an independent assessment of fuel cell durability status and discusses the project's relevance to the Department of Energy Hydrogen and Fuel Cells Program; NREL's analysis approach; the FY12 technical accomplishments including the fourth annual publication of results; and project collaborations and future work.

Kurtz, J.; Wipke,; Sprik, S.; Saur, G.

2012-06-01T23:59:59.000Z

6

Fellows' Prize Nominations  

NLE Websites -- All DOE Office Websites (Extended Search)

Nominations Fellows' Prize Nominations Prize details and nomination procedures. Fellows' Prize for Outstanding Research in Science or Engineering Purpose To commend individuals for...

7

State-of-the-Art Fuel Cell Voltage Durability Status: Spring 2013 Composite Data Products  

SciTech Connect

This presentation from the U.S. Department of Energy's National Renewable Energy Laboratory includes composite data products (CDPs) produced in 2013 for state-of-the-art fuel cell voltage durability status.

Kurtz, J.; Sprik, S.; Saur, G.; Peters, M.; Post, M.; Ainscough, C.

2013-05-01T23:59:59.000Z

8

Method for reducing fuel cell output voltage to permit low power operation  

DOE Patents (OSTI)

Fuel cell performance is degraded by recycling a portion of the cathode exhaust through the cells and, if necessary, also reducing the total air flow to the cells for the purpose of permitting operation below a power level which would otherwise result in excessive voltage.

Reiser, Carl A. (Glastonbury, CT); Landau, Michael B. (West Hartford, CT)

1980-01-01T23:59:59.000Z

9

Electrolytes and Separators for High Voltage Li Ion Cells  

Energy.gov (U.S. Department of Energy (DOE))

2012 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

10

Electrolytes and Separators for High Voltage Li Ion Cells  

Energy.gov (U.S. Department of Energy (DOE))

2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and Peer Evaluation

11

Electrolytes and Separators for High Voltage Li Ion Cells  

Energy.gov (U.S. Department of Energy (DOE))

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

12

Electrochemical Characterization of Voltage Fade in LMR-NMC cells  

Energy.gov (U.S. Department of Energy (DOE))

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

13

Polymer defect states modulate open-circuit voltage in bulk-heterojunction solar cells  

SciTech Connect

Defect states influence the operation of organic solar cells altering transport, recombination, and energetic mechanisms. This work investigates how processing conditions induce morphology-related, electrically active defects in the donor polymer of bulk-heterojunction solar cells. Structural order is inferred from absorption and X-ray diffraction data, while defect density is determined from capacitance methods. A correlation is observed between the polymer nanocrystallite size, the defect concentration, and the output voltage. For the case of poly(3-hexylthiophene), processing that promote crystallinity is beneficial for the device performance as it decreases the defect density (energy disorder) that finally enlarges the maximum achievable open-circuit voltage. Defect states within the effective bandgap modulate the downshift of the hole Fermi level upon illumination that in turn establishes the achievable open-circuit voltage.

Ripolles, Teresa S.; Guerrero, Antonio; Garcia-Belmonte, Germà, E-mail: garciag@uji.es [Photovoltaic and Optoelectronic Devices Group, Departament de Física, Universitat Jaume I, ES-12071 Castelló (Spain)] [Photovoltaic and Optoelectronic Devices Group, Departament de Física, Universitat Jaume I, ES-12071 Castelló (Spain)

2013-12-09T23:59:59.000Z

14

Monolithically interconnected GaAs solar cells: A new interconnection technology for high voltage solar cell output  

SciTech Connect

Photovoltaic linear concentrator arrays can benefit from high performance solar cell technologies being developed at AstroPower. Specifically, these are the integration of thin GaAs solar cell and epitaxial lateral overgrowth technologies with the application of monolithically interconnected solar cell (MISC) techniques. This MISC array has several advantages which make it ideal for space concentrator systems. These are high system voltage, reliable low cost monolithically formed interconnections, design flexibility, costs that are independent of array voltage, and low power loss from shorts, opens, and impact damage. This concentrator solar cell will incorporate the benefits of light trapping by growing the device active layers over a low-cost, simple, PECVD deposited silicon/silicon dioxide Bragg reflector. The high voltage-low current output results in minimal 12R losses while properly designing the device allows for minimal shading and resistance losses. It is possible to obtain open circuit voltages as high as 67 volts/cm of solar cell length with existing technology. The projected power density for the high performance device is 5 kW/m for an AMO efficiency of 26% at 1 5X. Concentrator solar cell arrays are necessary to meet the power requirements of specific mission platforms and can supply high voltage power for electric propulsion systems. It is anticipated that the high efficiency, GaAs monolithically interconnected linear concentrator solar cell array will enjoy widespread application for space based solar power needs. Additional applications include remote man-portable or ultra-light unmanned air vehicle (UAV) power supplies where high power per area, high radiation hardness and a high bus voltage or low bus current are important. The monolithic approach has a number of inherent advantages, including reduced cost per interconnect and increased reliability of array connections. There is also a high potential for a large number of consumer products.

Dinetta, L.C.; Hannon, M.H.

1995-10-01T23:59:59.000Z

15

Quadratic voltage profiles in lead acid cells during slow, steady processes  

E-Print Network (OSTI)

It is standard lore that the voltage profile varies linearly in space within the electrolyte of a lead acid cell under slow, steady discharge. However, this hypothesis has never been put to the test. A recent theory predicts a uniform, non...

Haaser, Robert Anthony

1999-01-01T23:59:59.000Z

16

Solar cells: A laboratory experiment on the temperature dependence of the open?circuit voltage  

Science Journals Connector (OSTI)

This paper describes a simple demonstration of the effect of an increase in temperature upon the performance of solar cells under concentrated light. It is shown that the expected increase of the open?circuit voltage is offset by the temperature effect. This experiment should be quite relevant as an introduction to the study of concentration for undergraduate physics laboratories.

A. Khoury; J?P. Charles; J. Charette; M. Fieux; P. Mialhe

1984-01-01T23:59:59.000Z

17

Amorphous silicon/polyaniline heterojunction solar cells: Fermi levels and open-circuit voltages  

E-Print Network (OSTI)

these open-circuit voltages are lower than for the best a-Si:H cells utilizing nanocrystalline Si or a reports on conducting polymer/ amorphous silicon (a-Si:H) structures [1­4] and conduct- ing polymer/crystalline silicon (c-Si) structures [5,6]. In this paper, we report our research on polyaniline (PANI)/a-Si:H

Schiff, Eric A.

18

Derivation of the open-circuit voltage of organic solar cells  

Science Journals Connector (OSTI)

Organic photovoltaic cells have improved in efficiency from 1% two decades ago to over 10% today. Continued improvement necessitates a theoretical understanding of the factors determining efficiency. Organic photovoltaic efficiency can be parameterized in terms of open-circuit voltage, short-circuit current, and fill factor. Here we present a theory that explains the dependencies of open-circuit voltage on semiconductor energy levels, light intensity, solar cell and light-source temperatures, charge-carrier recombination, and external fluorescence efficiency. The present theory also explains why recombination at the donor-acceptor heterointerface is a dominant process in heterojunction-based cells. Furthermore, the Carnot efficiency appears, highlighting the connection to basic thermodynamics. The theory presented here is consistent with and builds on the experimental and theoretical observations already in the literature. Crucially, the present theory can be straightforwardly derived in a line-by-line fashion using standard tools from statistical physics.

Douglas B. Staple; Patricia A. K. Oliver; Ian G. Hill

2014-05-20T23:59:59.000Z

19

Automatic voltage imbalance detector  

DOE Patents (OSTI)

A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

1984-01-01T23:59:59.000Z

20

Voltage Dependent Carrier Collection in CdTe Solar Cells D.L. Btzner1  

E-Print Network (OSTI)

Voltage Dependent Carrier Collection in CdTe Solar Cells D.L. Bätzner1 , Guido Agostinelli2 , A to 1000nm, i.e. the band edge region of CdTe. Region I is further divided in a `blue' part between 300 nm III is as well subdivided in region IIIa from about 800 nm to the band gap of CdTe (~850 nm

Romeo, Alessandro

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Boosting the voltage of a salinity-gradient-power electrochemical cell by means of complex-forming solutions  

E-Print Network (OSTI)

with respect to other well-known techniques that work quasi-reversibly, such as reverse electrodialysis luminance decay and voltage drift in polymer light-emitting electrochemical cells: Forward bias vs. reverse is significantly higher than the voltage obtained with the other quasi-reversible techniques. We show

Carati, Andrea

22

Voltage Oscillations in Single-Chamber Fuel Cells operating under a C3H8 / O2 mixture.  

E-Print Network (OSTI)

1 Voltage Oscillations in Single-Chamber Fuel Cells operating under a C3H8 / O2 mixture. Geoffroy : Jean-Paul Viricelle, viricelle@emse.fr Phone : 33 4 77 42 02 52 Abstract : Single-Chamber Fuel Cells this behaviour. Keywords: Single Chamber Fuel Cell, Propane, Oscillation, Anode. 1. Introduction Solid Oxide Fuel

Paris-Sud XI, Université de

23

Josh Beale Candidate Statement Nominators  

E-Print Network (OSTI)

Josh Beale ­ Candidate Statement Nominators: Rosa Nobarni Audrey Chan Since I started my university

New South Wales, University of

24

High open circuit voltages of solar cells based on quantum dot and dye hybrid-sensitization  

SciTech Connect

A type of solar cell based on quantum dot (QD) and dye hybrid-sensitized mesoporous TiO{sub 2} film electrode was designed and reported. The electrode was consisted of a TiO{sub 2} nanoparticle (NP) thin film layer sensitized with CdS quantum dot (QD) and an amorphous TiO{sub 2} coated TiO{sub 2} NP thin film layer that sensitized with C106 dye. The amorphous TiO{sub 2} layer was obtained by TiCl{sub 4} post-treatment to improve the properties of solar cells. Research showed that the solar cells fabricated with as-prepared hybrid-sensitized electrode exhibited excellent photovoltaic performances and a fairly high open circuit voltage of 796?mV was achieved.

Zhao, Yujie; Zhao, Wanyu; Chen, Jingkuo; Li, Huayang; Fu, Wuyou, E-mail: hari@hpu.edu.cn, E-mail: fuwy56@163.com; Sun, Guang; Cao, Jianliang; Zhang, Zhanying [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China)] [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China); Bala, Hari, E-mail: hari@hpu.edu.cn, E-mail: fuwy56@163.com [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China) [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China); College of Chemistry and Chemical Engineering, Inner Mongolia University for the Nationalities, Tongliao 028043 (China)

2014-01-06T23:59:59.000Z

25

Secretarial Award Nomination Form  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Secretary's Awards Program Nomination Form Secretary's Awards Program Nomination Form 1. Type of Award (Check Applicable Box) Secretary's Honor Awards Secretary's Departure Awards Secretary's James R. Schlesinger Award Exceptional Service Award Appreciation Award Excellence Award Distinguished Service Award Achievement Award Meritorious Service Award 2. Nominee (Full) Name Check if Group list is attached (As it is to appear on the certificate) For Departure and Appreciation Awards Only 3. Certificate Date 4. Award Presentation Date 5. Current Position Title 6. Award Justification: Continue on blank sheet of paper and attach if you need more space. 7. Award Citation: A citation of no more than 20 lines must be attached to nomination form. 8 . Requesting Office : 9a. Local Approvals: One or more signatures is typical but not required

26

Modified design of radioisotope thermophotovoltaic generator to mitigate adverse effect of measured cell voltage  

SciTech Connect

A preceding OSC paper described a number of changes in the data base and in the methods--considerably more rigorous than those employed in the past--for analyzing the performance of Radioisotope Thermophotovoltaic (RTPV) converters. As shown, some of those changes were beneficial, but others--particularly the use of EDTEK`s experimentally measured open-circuit voltages and fill factors instead of previously used theoretical equations--had a substantial adverse effect on the predicted converter performance. EDTEK is continuing work on improved PV cells to more closely approach theoretical voltage predictions. In parallel with that effort, OSC has been investigating a number of generator design modifications to achieve additional improvements in system performance. Specifically, OSC found that the converter`s performance could be significantly improved by increasing the heat flux incident on the PV cells. As will be explained, OSC`s preferred design, which entails placing the TPV converters on the housing`s end covers instead of its side walls, not only improves the generator`s performance but also offers important programmatic, fabrication, and processing advantages.

Schock, A.; Or, C.T.; Kumar, V. [Orbital Sciences Corp., Germantown, MD (United States)

1996-12-31T23:59:59.000Z

27

The characteristics of voltage degradation of a proton exchange membrane fuel cell under a road operating environment  

Science Journals Connector (OSTI)

Abstract A real-life testing experiment of a proton exchange membrane fuel cell (PEMFC) and the basic characteristics of its voltage degradation are presented. A general package radio system (GPRS)-based remote monitoring system was used as the data acquisition method, and the non-linear regression method was used to estimate PEMFC's polarization curve within specific iso-interval periods. The voltage degradation rate was calculated using the differential method, and its average level was also analyzed. The experimental results indicated that the voltage degradation rate at a specific current density featured a bathtub-like curve, exhibiting 1) infant degradation, 2) steady degradation, 3) and accelerated degradation.

Xinfeng Zhang; Yang Rui; Zhang Tong; Xu Sichuan; Shen Yong; Ni Huaisheng

2014-01-01T23:59:59.000Z

28

Boosting the voltage of a salinity-gradient-power electrochemical cell by means of complex-forming solutions  

Science Journals Connector (OSTI)

We report experiments on a concentration cell with zinc electrodes and ZnCl2 solutions at different concentrations separated by a porous diaphragm. The cell is aimed at the conversion of the free energy associated to the concentration difference into electrical energy for renewable and clean energy applications. Usually the diffusion of the solute across the diaphragm constitutes a waste of free energy which impairs the voltage generation of the concentration cell with respect to other well-known techniques that work quasi-reversibly such as reverse electrodialysis or the “mixing entropy battery.” Quite surprisingly we find that the voltage produced by our concentration cell is significantly higher than the voltage obtained with the other quasi-reversible techniques. We show that the surplus voltage comes from the active transformation of the mixing free energy into electrical energy performed by the liquid junction and we show the connection with the negative apparent transference number of the zinc ion. This fortunate consequence of using ZnCl2 solution is ultimately related to the formation of complexes. We present the results of a cell for power production which has excellent performances with respect to known salinity-difference-power methods.

2014-01-01T23:59:59.000Z

29

Relationship between energetic disorder and open-circuit voltage in bulk heterojunction organic solar cells  

Science Journals Connector (OSTI)

We simulate organic bulk heterojunction solar cells. The effects of energetic disorder are incorporated through a Gaussian or exponential model of density of states. Analytical models of open-circuit voltage (VOC) are derived from the splitting of quasi-Fermi potentials. Their predictions are backed up by more complex numerical device simulations including effects such as carrier-density–dependent charge-carrier mobilities. It is predicted that the VOC depends on: (1) the donor-acceptor energy gap; (2) charge-carrier recombination rates; (3) illumination intensity; (4) the contact work functions (if not in the pinning regime); and (5) the amount of energetic disorder. A large degree of energetic disorder, or a high density of traps, is found to cause significant reductions in VOC. This can explain why VOC is often less than expected in real devices. Energetic disorder also explains the nonideal temperature and intensity dependence of VOC and the superbimolecular recombination rates observed in many real bulk heterojunction solar cells.

James C. Blakesley and Dieter Neher

2011-08-12T23:59:59.000Z

30

Built-in voltage of organic bulk heterojuction p-i-n solar cells measured by electroabsorption spectroscopy  

SciTech Connect

We investigate the influence of the built-in voltage on the performance of organic bulk heterojuction solar cells that are based on a p-i-n structure. Electrical doping in the hole and the electron transport layer allows to tune their work function and hence to adjust the built-in voltage: Changing the doping concentration from 0.5 to 32 wt% induces a shift of the work function towards the transport levels and increases the built-in voltage. To determine the built-in voltage, we use electroabsorption spectroscopy which is based on an evaluation of the spectra caused by a change in absorption due to an electric field (Stark effect). For a model system with a bulk heterojunction of BF-DPB and C{sub 60}, we show that higher doping concentrations in both the electron and the hole transport layer increase the built-in voltage, leading to an enhanced short circuit current and solar cell performance.

Siebert-Henze, E., E-mail: ellen.siebert@iapp.de; Lyssenko, V. G.; Fischer, J.; Tietze, M.; Brueckner, R.; Schwarze, M.; Vandewal, K.; Ray, D.; Riede, M.; Leo, K. [Institut für Angewandte Photophysik, Technische Universität Dresden, D-01062 Dresden (Germany)] [Institut für Angewandte Photophysik, Technische Universität Dresden, D-01062 Dresden (Germany)

2014-04-15T23:59:59.000Z

31

Correlations of Capacitance-Voltage Hysteresis with Thin-Film CdTe Solar Cell Performance During Accelerated Lifetime Testing  

SciTech Connect

In this paper we present the correlation of CdTe solar cell performance with capacitance-voltage hysteresis, defined presently as the difference in capacitance measured at zero-volt bias when collecting such data with different pre-measurement bias conditions. These correlations were obtained on CdTe cells stressed under conditions of 1-sun illumination, open-circuit bias, and an acceleration temperature of approximately 100 degrees C.

Albin, D.; del Cueto, J.

2011-03-01T23:59:59.000Z

32

A straightforward method to extract the shunt resistance of photovoltaic cells from current–voltage characteristics of mounted arrays  

Science Journals Connector (OSTI)

A straightforward non-invasive method is proposed to accurately evaluate the shunt resistance of an elementary cell of a photovoltaic module connected in an installed string without requiring prior knowledge of the parameters of the intrinsic diodes. The approach relies on the measurement of the current–voltage characteristic of the whole string after intentionally shading the selected cell. Calibrated PSPICE simulations are employed to illustrate the method and test its reliability. As a case study, the shunt resistances of several cells belonging to a series array of 10 commercial panels are determined.

Vincenzo d’Alessandro; Pierluigi Guerriero; Santolo Daliento; Matteo Gargiulo

2011-01-01T23:59:59.000Z

33

Open-circuit voltage, fill factor, and efficiency of a CdS/CdTe solar cell  

SciTech Connect

The dependences of the open-circuit voltage, fill factor, and efficiency of the thin-film CdS/CdTe solar cell on the resistivity {rho} and carrier lifetime {tau} in the absorbing CdTe layer were studied. In the common case in which the uncompensated acceptor concentration and the electron lifetime in the CdTe layer are within 10{sup 15}-10{sup 16} cm{sup -3} and 10{sup -10}-10{sup -9} s, the calculation results correspond to the achieved efficiency of the best thin-film CdS/CdTe solar cells. It was shown that, by decreasing {rho} and increasing {tau} in the absorbing CdTe layer, the open-circuit voltage, fill factor, and efficiency can be substantially increased, with their values approaching the theoretical limit for such devices.

Kosyachenko, L. A., E-mail: lakos@chv.ukrpack.net; Grushko, E. V. [Yuriy Fedkovych Chernivtsi National University (Ukraine)

2010-10-15T23:59:59.000Z

34

Compression-Induced Open Circuit Voltage Increase in All-Polymer Solar Cells with Lithium Fluoride Nanolayers  

Science Journals Connector (OSTI)

Compression-Induced Open Circuit Voltage Increase in All-Polymer Solar Cells with Lithium Fluoride Nanolayers ... The P3HT polymer (weight-average molecular weight = 50 kDa; polydispersity index = 2.2) was used as received from Rieke Metals (Nebraska, U.S.A.), while the F8BT polymer (weight-average molecular weight = 46 kDa) was supplied from American Dye Sources (Quebec, Canada). ...

Sooyong Lee; Sungho Nam; Hwajeong Kim; Youngkyoo Kim

2013-08-08T23:59:59.000Z

35

WYSS TECHNOLOGY DEVELOPMENT FELLOWSHIP NOMINATION FORM  

E-Print Network (OSTI)

WYSS TECHNOLOGY DEVELOPMENT FELLOWSHIP NOMINATION FORM 1. Biographical Sketch _____________________________________________ ________________________________________ Wyss Enabling Technology Platform Focus research plans relative to Wyss Enabling Technology Platform. 3. Enclose supporting letter from nominator

36

Superconducting Coil fed by PEM Fuel Cell M. Hinaje, K. Berger, J. Lvque, B. Davat  

E-Print Network (OSTI)

Superconducting Coil fed by PEM Fuel Cell M. Hinaje, K. Berger, J. Lévêque, B. Davat Université de, 54516 Vandoeuvre-lès-Nancy, France Melika.Hinaje@univ-lorraine.fr Abstract- Fuel cells and around 0.6 V in nominal conditions of power generation. Fuel cells are then by essence low voltage

Boyer, Edmond

37

International Phenomenological Society On Nominalism  

E-Print Network (OSTI)

International Phenomenological Society On Nominalism Author(s): Geoffrey Hellman Source: Philosophy and Phenomenological Research, Vol. 62, No. 3 (May, 2001), pp. 691-705 Published by: International Phenomenological contact support@jstor.org. . International Phenomenological Society is collaborating with JSTOR

Hellman, Geoffrey

38

National Defense University (NDU) Nomination Package Checklist  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

- November 2012 - November 2012 National Defense University (NDU) Nomination Package Checklist SEND 2 COPIES OF THE NOMINATION PACKAGE TO THE NDU UNIVERSITY REGISTRAR'S OFFICE Each student nomination package must include the following items: NDU Student Nomination Form One official transcript (highest degree earned) One-page student biography or résumé (include education and career history) Two Letters of Recommendation World-Wide Travel Statement Statement of Purpose (No more than two pages) Signed National Defense University Privacy Act Statement Signed Education Release Form (if nominating agency requires copies of final student evaluation and/or transcript) SAC students must also include: Senior Acquisition Course Nomination Form

39

Voltage-Dependent K+ Channels as Targets of Osmosensing in Guard Cells  

Science Journals Connector (OSTI)

...CCD-1317K/2 camera (Princeton Instrument, Inc., Trenton...Osmogradients across the Plasma Membrane Regulate I Kin and...Stretch-Activated K+ Channels in the Plasma Membrane of Guard Cells...calcium channels coexisting in plasma membranes of guard cells of...

Kun Liu; Sheng Luan

40

Tetrapropyl-tetraphenyl-diindenoperylene derivative as a green absorber for high-voltage stable organic solar cells  

Science Journals Connector (OSTI)

We present small molecule organic solar cells (SMOSC) based on flat heterojunctions (FHJ) of the alternative green donor 2,3,10,11-tetrapropyl-1,4,9,12-tetraphenyl-diindeno[1,2,3-cd:1’,2’,3’-lm]perylene (P4-Ph4-DIP) and the fullerene C60. P4-Ph4-DIP absorbs in the green spectral range and thus fills the spectral gap that standard absorber materials (zinc or copper phthalocyanine for red and C60 for blue absorption) leave, thus allowing broad coverage of the sun spectrum, which is of major interest for tandem devices. The materials properties of P4-Ph4-DIP are studied, and SMOSC are characterized by current voltage, external quantum efficiency, and aging measurements. The solar cells display very high fill factors FF > 76% and open circuit voltages VOC of close to 1 V. Mismatch-corrected efficiencies of up to 1.9% are obtained. Aging measurements show that C60 in conjunction with P4-Ph4-DIP yields extremely stable devices. We observe ? 88% of the initial efficiency after 2500 h illumination at 999 mW/cm2 illumination intensity, with no observable change in short-circuit current density. Furthermore, we also show that a systematic variation of donor thickness in FHJ can be combined with transfer matrix formalism-based optical simulations and the continuity equation for excitons to reliably determine the exciton diffusion length LD. A value of 9 ± 1 nm is found for P4-Ph4-DIP.

Jan Meiss; Martin Hermenau; Wolfgang Tress; Christoph Schuenemann; Franz Selzer; Markus Hummert; Joerg Alex; Gerhard Lackner; Karl Leo; Moritz Riede

2011-04-11T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

2015 Federal Energy and Water Management Awards: Nomination Quick...  

Energy Savers (EERE)

Nomination Quick Reference 2015 Federal Energy and Water Management Awards: Nomination Quick Reference Document offers a checklist of items needed to complete a nomination for the...

42

Enhancement of the Morphology and Open Circuit Voltage in Bilayer Polymer/Fullerene Solar Cells  

Science Journals Connector (OSTI)

We describe the influence of thermal annealing on the performance of polymer bilayer solar cell devices of regioregular poly(3-hexylthiophene), regiorandom poly(3-hexylthiophene), or poly(3-hexyl-2,5-thienylene vinylene) (P3HTV), with C60 as the electron ...

Derek M. Stevens; Yang Qin; Marc A. Hillmyer; C. Daniel Frisbie

2009-06-09T23:59:59.000Z

43

Low circumferential voltage gradient self supporting electrode for solid oxide fuel cells  

DOE Patents (OSTI)

The porous, self-supporting, elongated electrode is made, having at least two chambers through its axial length, the chambers separated by an electronically conductive member. This electrode can be an air electrode of a fuel cell, having a superimposed solid electrolyte and fuel electrode.

Reichner, Philip (Plum Boro, PA)

1989-01-01T23:59:59.000Z

44

Microsoft Word - fellows_nomination_reworked.doc  

NLE Websites -- All DOE Office Websites (Extended Search)

of Contents 2) Letter of Nomination 3) Letters of Endorsement 4) CVResume 5) Publications and Citations Contains Export Control Sensitive Information...

45

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2013 DOE Hydrogen and Fuel Cells Program and...

46

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2012 DOE Hydrogen and Fuel Cells Program and...

47

Cathode Synthesis and Voltage Fade: Designed Solutions Based...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cathode Synthesis and Voltage Fade: Designed Solutions Based on Theory Cathode Synthesis and Voltage Fade: Designed Solutions Based on Theory 2013 DOE Hydrogen and Fuel Cells...

48

Agency Energy Coordinators for Award Nominations  

Energy.gov (U.S. Department of Energy (DOE))

Federal agency energy coordinators handle all nominations for the Federal Energy and Water Management Awards. Contact your agency energy coordinator well in advance of all award deadlines to learn...

49

210 nature neuroscience volume 5 no 3 march 2002 Calcium entry into cells through voltage-gated Ca2+ channels  

E-Print Network (OSTI)

voltage-gated Ca2+ channels initiates a wide range of cellular processes including protein phosphorylation, gene expression and neurotransmitter release1. Neuronal Ca2+ channels consist of a pore-forming 1 by neurotransmitters inhibits Cav2.1 and Cav2.2 channels, which mediate P/Q-type and N- type Ca2+ currents

Palczewski, Krzysztof

50

Low electrical potential anode modified with Fe/ferric oxide and its application in marine benthic microbial fuel cell with higher voltage and power output  

Science Journals Connector (OSTI)

Abstract Low voltage and power output limit the widespread application of marine benthic microbial fuel cell (BMFCs). To increase the cell power, a Fe/Ferric oxide modified anode fabricating by electrolytic deposition is reported here. The novel anode has a lower surface contact angle and higher wettability, which favors the adhesion of bacteria. It is firstly demonstrated that the electrical potential of the modified anode is about ?775 mV, much lower than that of the plain graphite (about ?450 mV). Open circuit potential of BMFC with the modified anode is about 1050 ± 50 mV, while the potential for the plain cells is only 700 ± 50 mV. In comparison with the plain graphite, the modified anode presents a 393-fold exchange current density and a higher kinetic activity. The output power reaches 7.4 × 10?2 mW cm?2, 17.4-fold higher than that of the plain graphite. A composite mechanism of both chemical and microbial enhancement of the modified anode is proposed to explain its excellent electrochemical performance. The modified anode has potential for high-power output cell and novel voltage-booster design to make the BMFC utilization feasibility.

Yubin Fu; Qian Xu; Xuerong Zai; Yuanyuan Liu; Zhikai Lu

2014-01-01T23:59:59.000Z

51

Nominate Your Mentor for the Presidential Award in Science, Math...  

Office of Environmental Management (EM)

Nominate Your Mentor for the Presidential Award in Science, Math, and Engineering Mentoring Nominate Your Mentor for the Presidential Award in Science, Math, and Engineering...

52

Integrated polymer solar cells in serial architecture with patterned charge-transporting MoOx for miniature high-voltage sources  

Science Journals Connector (OSTI)

We develop miniature high-voltage sources from polymer solar cells (PSCs) with charge-transporting molybdenum oxide (MoOx) integrated in a serial architecture through sacrificial layer (SL)-assisted patterning. The MoOx layer, being patterned by the lift-off process of the SL of a hydrophobic fluorinated-polymer, as a hole transporting layer plays a critical role on the reduction of the dark current and the increase of a high open circuit voltage of an integrated PSC array. The underlying mechanism lies primarily on the elimination of the lateral charge pathways in the MoOx layer in the presence of the electrode interconnection. Two miniature voltage sources consisting of 20 PSCs and 50 PSCs are demonstrated in the operation of a liquid crystal display and an organic field-effect transistor, respectively. Our SL-assisted integration approach will be directly applicable for implementing the self-power sources made of the PSCs into a wide range of the electronic and optoelectronic devices.

Seong-Min Cho; Chang-Min Keum; Hea-Lim Park; Min-Hoi Kim; Jin-Hyuk Bae; Sin-Doo Lee

2014-01-01T23:59:59.000Z

53

Development of a technique for ex-reactor heating of electrodes and for obtaining voltage-current characteristics of multi-cell thermionic fuel elements  

SciTech Connect

This paper presents results of development of a technique for ex-reactor heating with simultaneous recording of voltage-current characteristics of multi-cell thermionic fuel elements (TFE). Heating pulses were applied to electrodes of a thermionic energy converter (TIC), and between these pulses in the antiphase to them there were applied shorter pulses. The TIC emitter was heated by energy of an electric current flowing from the collector (back current heating). Comparison of TIC voltage-current characteristics, obtained for direct (using electric heater) and back current (current from the collector) heating, shows that for the same conditions they differ only slightly. Significant difference may be observed in the case of different profiles along the collector working surface. Results are given of the investigation of multi-cell thermionic fuel assemblies conducted using this technique. The developed technique of the TFE diagnostics can be successfully employed to assess the device quality. Pre-loop testing of multi-cell TFE by the method of back currents allows for cost effective and expeditious thermovacuum treatment of the TFE on thermal stands and for checking of its serviceability prior to its mounting into an irradiation loop or reactor-converter, enables improvements to the TFE design, monitoring of its electric parameters, for example, after vibration testing, and TFE accelerated testing in the most arduous conditions (thermocycling, loss of vacuum, etc.).

Kalandarishvili, A.G.; Mailov, G.M.; Igumnov, B.N.; Bisko, V.A. [I.N. Vekua Sukhumi Inst. for Physics and Engineering, Tbilisi (Georgia)

1995-12-31T23:59:59.000Z

54

Treatment of model inland brackish groundwater reverse osmosis concentrate with electrodialysis — Part II: Sensitivity to voltage application and membranes  

Science Journals Connector (OSTI)

Abstract The objective of this research was to investigate the sensitivity of electrodialysis performance to variations in voltage application and membranes when treating brackish water reverse osmosis concentrate waste. Synthetic BWRO concentrates from Arizona and Texas of 7890–14,800 mg/L total dissolved solids were prepared with poly-phosphonate antiscalants. Experimentation was performed using a laboratory-scale electrodialyzer with two sets of membranes (AMV-CMV and PCSA-PCSK) with a nominal transfer area of 64 cm2 per membrane. Flow, pressure, conductivity, temperature, and pH were measured continuously, and periodic samples were analyzed for specific anion and cation concentrations. The BWRO concentrates were successfully treated with stack voltage applications of 0.5–1.5 V/cell-pair for salinity removal ratios up to 99% with current density less than 500 A/m2. This paper highlights that (1) the specific energy consumption was proportional to the applied voltage and equivalent concentration separated (i.e., approximately 0.03 kW h/m3 per Volt/cell-pair applied per meq/L separated); (2) lower voltage applications decreased the relative separation rate of sulfate compared to chloride; and (3) water transport by electro-osmosis was independent of voltage application or resulting current densities, while it is affected by the ion exchange membranes.

W. Shane Walker; Younggy Kim; Desmond F. Lawler

2014-01-01T23:59:59.000Z

55

Theoretical Analysis of Effects of Deep Level, Back Contact, and Absorber Thickness on Capacitance-Voltage Profiling of CdTe Thin-Film Solar Cells  

SciTech Connect

The apparent carrier density profile measured by the capacitance-voltage technique in CdTe thin-film solar cells frequently displays a distinctive U-shape. We show that, even assuming a uniform carrier density, such a U-shape may arise from deep levels, a non-ohmic back-contact, and a thin absorber, which are commonly present in practical CdTe thin-film solar cells. A thin CdTe absorber contributes to the right branch of the U-shape due to a punch-through effect at reverse or zero biases, when the CdTe absorber is nearly fully depleted. A rectifying back-contact contributes to both branches of the U-shape due to voltage sharing with the front junction under a forward bias and early punch-through under a reverse bias. Deep levels contribute to the right branch, but also raise the bottom of the U-shape, leading to an overestimate of carrier density.

Li, J. V.; Halverson, A. F.; Sulima, O. V.; Bansal, S.; Burst, J. M.; Barnes, T. M.; Gessert, T. A.; Levi, D. H.

2012-05-01T23:59:59.000Z

56

Cerebellar Purkinje cell death in the P/Q -type voltage-gated calcium ion channel mutant mouse, leaner  

E-Print Network (OSTI)

inducing an inflammatory response in the tissue surrounding the affected cell (Sastry and Rao, 2000; Yuan and Yankner, 2000; Yuan, et al., 2003). Programmed cell death is an essential requirement for normal neurodevelopment and a key component of many...

Frank-Cannon, Tamy Catherine

2006-04-12T23:59:59.000Z

57

Vehicle Technologies Office Merit Review 2014: Characterization of Voltage Fade in Lithium-ion Cells with Layered Oxides  

Energy.gov (U.S. Department of Energy (DOE))

Presentation given by Argonne National Laboratory at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about characterization...

58

Optimal Placement of the Wind Generators in the Medium Voltage Power Grid  

Science Journals Connector (OSTI)

The minimization of power losses in the medium voltage (MV) grid requires adjustment of network of power sources. This problem is particularly important for renewable energy sources, for example for the farms of wind generators. Their placement and nominal ... Keywords: medium voltage power grid, wind generators, genetic algorithms, parallel processing

Andrzej Jordan; Ryszard Szczebiot; Carsten Maple; Slawomir Cieslik

2011-04-01T23:59:59.000Z

59

Neurodegeneration in cerebellar granule cells of p/q type voltage gated calcium channel mutant leaner mice  

E-Print Network (OSTI)

the extent of neuronal cell death, basal intracellular calcium and mitochondrial (dys)function in cerebellar granule cells (CGC) of adult leaner mice; 2) to analyze the role of the leaner calcium channel mutation on postnatal development of CGCs; and 3...

Bawa, Bhupinder

2009-05-15T23:59:59.000Z

60

A novel approach for the improvement of open circuit voltage and fill factor of InGaAsSb/GaSb thermophotovoltaic cells  

SciTech Connect

Heterojunction n-Al{sub 0.25}Ga{sub 0.75}As{sub 0.02}Sb{sub 098}/p-In{sub 0.16}Ga{sub 0.84}As{sub 0.04}Sb{sub 0.96} thermophotovoltaic (TPV) cells were grown by molecular-beam epitaxy on n-GaSb-substrates. In the spectral range from 1 {micro}m to 2.1 {micro}m these cells, as well as homojunction n-p-In{sub 0.16}Ga{sub 0.84}As{sub 0.04}Sb{sub 0.96} cells, have demonstrated internal quantum efficiencies exceeding 80%, despite about a 200 meV barrier in the conduction band at the heterointerface. Estimation shows that the thermal emission of the electrons photogenerated in p-region over this barrier can provide high efficiency for hetero-cells if the electron recombination time in p-In{sub 0.16}Ga{sub 0.84}As{sub 0.04}Sb{sub 0.96}is longer than 10 ns. Keeping the same internal efficiency as homojunction cells, hetero-cells provide a unique opportunity to decrease the dark forward current and thereby increase open circuit voltage (V{sub {proportional_to}}) and fill factor at a given illumination level. It is shown that the decrease of the forward current in hetero-cells is due to the lower recombination rate in n-type wider-bandgap space-charge region and to the suppression of the hole component of the forward current. The improvement in V{sub {proportional_to}} reaches 100% at illumination level equivalent to 1 mA/cm{sup 2} and it decreases to 5% at the highest illumination levels (2--3 A/cm{sup 2}), where the electron current component dominates in both the homo- and heterojunction cells. Values of V{sub {proportional_to}} as high as 310 meV have been obtained for a hetero-cell at illumination levels of 3 A/cm{sup 2}. Under this condition, the expected fill factor value is about 72% for a hetero-cell with improved series resistance. The heterojunction concept provides excellent prospects for further reduction of the dark forward current in TPV cells.

Garbuzov, D.Z.; Martinelli, R.U.; Khalfin, V.; Lee, H.; Morris, N.A.; Taylor, G.C.; Connolly, J.C. [Sarnoff Corp., Princeton, NJ (United States); Charache, G.W.; DePoy, D.M. [Lockheed-Martin, Inc., Schenectady, NY (United States)

1997-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Aviation Management Professional Award Nomination for:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Professional Nomination for Professional Nomination for Managerial/Official Award: Joseph M. Ginanni Aviation Manager US Department of Energy/National Nuclear Security Administration, Nevada Site Office Bio Joseph M. Ginanni Aviation Manager National Nuclear Security Administration Nevada Site Office Mr. Ginanni has worked for the Nevada Site Office (NSO) since 1991. For the past five years, he has served as the NSO Aviation Manager, managing and overseeing the Management and Operating contractor's aviation services department and their operation and maintenance of NSO's five aircraft (3 Beechcraft King Airs and 2 Bell 412s) which are stationed at both Nellis AFB, NV and Andrews AFB, MD. Prior to his position as Aviation Manager, he was the team leader for the Radioactive Waste

62

Full Abstraction for Nominal General References  

E-Print Network (OSTI)

}. For each m (MA \\ IA): iA A m1 A · · · A mi A m Initial moves are P-Answers,and whenever m1 A m2, m1, m2 The -calculus is a functional calculus with nominal references. TY A, B ::= ½ | � | [A] | A B | A B TE M, N ::= x | x.M | M N -term | skip return | n | pred M | succ N arithmetic | if0 M then N1 else N2

63

Nominal Performance Biosphere Dose Conversion Factor Analysis  

SciTech Connect

The purpose of this report was to document the process leading to development of the Biosphere Dose Conversion Factors (BDCFs) for the postclosure nominal performance of the potential repository at Yucca Mountain. BDCF calculations concerned twenty-four radionuclides. This selection included sixteen radionuclides that may be significant nominal performance dose contributors during the compliance period of up to 10,000 years, five additional radionuclides of importance for up to 1 million years postclosure, and three relatively short-lived radionuclides important for the human intrusion scenario. Consideration of radionuclide buildup in soil caused by previous irrigation with contaminated groundwater was taken into account in the BDCF development. The effect of climate evolution, from the current arid conditions to a wetter and cooler climate, on the BDCF values was evaluated. The analysis included consideration of different exposure pathway's contribution to the BDCFs. Calculations of nominal performance BDCFs used the GENII-S computer code in a series of probabilistic realizations to propagate the uncertainties of input parameters into the output. BDCFs for the nominal performance, when combined with the concentrations of radionuclides in groundwater allow calculation of potential radiation doses to the receptor of interest. Calculated estimates of radionuclide concentration in groundwater result from the saturated zone modeling. The integration of the biosphere modeling results (BDCFs) with the outcomes of the other component models is accomplished in the Total System Performance Assessment (TSPA) to calculate doses to the receptor of interest from radionuclides postulated to be released to the environment from the potential repository at Yucca Mountain.

Wasiolek, Maryla A.

2000-12-21T23:59:59.000Z

64

Price of Cameron, LA Natural Gas LNG Imports (Nominal Dollars...  

Annual Energy Outlook 2012 (EIA)

(Nominal Dollars per Thousand Cubic Feet) Price of Cameron, LA Natural Gas LNG Imports (Nominal Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5...

65

Statement from Energy Secretary Samuel W. Bodman on the Nomination...  

Energy Savers (EERE)

Nomination of Thomas P. D'Agostino as Under Secretary for Nuclear Security and Administrator of NNSA Statement from Energy Secretary Samuel W. Bodman on the Nomination of Thomas P....

66

2015 Federal Energy and Water Management Awards: Nomination Quick Reference  

Energy.gov (U.S. Department of Energy (DOE))

Document offers a checklist of items needed to complete a nomination for the 2015 Federal Energy and Water Management Awards.

67

NREL: Measurements and Characterization - Current Versus Voltage  

NLE Websites -- All DOE Office Websites (Extended Search)

Current Versus Voltage Current Versus Voltage The National Renewable Energy Laboratory (NREL) Device Performance group uses current versus voltage (I-V) measurement systems to assess the main performance parameters for photovoltaic (PV) cells and modules. I-V measurement systems determine the output performance of devices, including: open-circuit voltage (Voc), short-circuit current (Isc), fill factor (FF), maximum power output of the device (Pmax), voltage at maximum power (Vmax), current at maximum power (Imax), and conversion efficiency of the device (η). Some I-V systems may also be used to perform dark I-V measurements to determine diode properties and series and shunt resistances. We use three I-V systems to measure performance of individual PV cells; and four for modules - two for measurements under simulated conditions; and

68

ccsd-00014522,version1-5Oct2006 Co-transport-induced instability of membrane voltage in tip-growing cells  

E-Print Network (OSTI)

ccsd-00014522,version1-5Oct2006 Co-transport-induced instability of membrane voltage in tip at the same time. It is shown that these co-transporters destabilize generically the membrane voltage- tive dynamics and activity of membrane ion channels. Action potential and cardiac excitation spiral

Paris-Sud XI, Université de

69

Analysis of Laboratory Fuel Cell Technology Status … Voltage Degradation - DOE Hydrogen and Fuel Cells Program FY 2012 Annual Progress Report  

NLE Websites -- All DOE Office Websites (Extended Search)

FY 2012 Annual Progress Report DOE Hydrogen and Fuel Cells Program Jennifer Kurtz (Primary Contact), Keith Wipke, Sam Sprik, Genevieve Saur, Huyen Dinh National Renewable Energy Laboratory (NREL) 15013 Denver West Parkway Golden, CO 80401-3305 Phone: (303) 275-4061 Email: jennifer.kurtz@nrel.gov DOE Manager HQ: Kathi Epping Martin Phone: (202) 586-7425 Email: Kathi.Epping@ee.dog.gov Project Start Date: July 1, 2009 Project End Date: Project continuation and direction determined annually by DOE Fiscal Year (FY) 2012 Objectives Conduct an independent assessment to benchmark * state-of-the-art fuel cell durability in a non-proprietary method Leverage analysis experience from the Fuel Cell Electric * Vehicle Learning Demonstration project Collaborate with key fuel cell developers on the analysis

70

FinalTestimonyLaneNominationStatement.pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

JEFF LANE, NOMINEE TO BE AN ASSISTANT JEFF LANE, NOMINEE TO BE AN ASSISTANT SECRETARY OF ENERGY, CONGRESSIONAL AND INTERGOVERNMENTAL AFFAIRS, DEPARTMENT OF ENERGY MARCH 17, 2010 Chairman Bingaman, Ranking Member Murkowski, and distinguished Members of the Committee, it is an honor and a privilege to appear before you today as President Obama's nominee for Assistant Secretary of Energy for Congressional and Intergovernmental Affairs. I want to thank Secretary Chu for recommending me to the President and thank the Committee for holding this hearing. As you consider my nomination for this position, I hope you will take into account my record, my experiences and my commitment of service to the Congress and to the important mission of the Department of Energy. I have spent most of my professional life - almost 16 years - serving in senior staff positions in

71

DOE General Counsel Nomination Announcement | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

General Counsel Nomination Announcement General Counsel Nomination Announcement DOE General Counsel Nomination Announcement March 18, 2009 - 12:00am Addthis WASHINGTON, DC - Today, President Barack Obama announced his intent to nominate the following individuals to key administration posts: Susan Burk, Special Representative of the President, with the rank of Ambassador, State Department; Raphael Bostic, Assistant Secretary for Policy Development and Research, Department of Housing and Urban Development; Michelle J. DePass, Assistant Administrator for International Affairs, Environmental Protection Agency; Cynthia J. Giles, Assistant Administrator for Enforcement and Compliance Assurance, Environmental Protection Agency; Michael L. Connor, Director, Bureau of Reclamation, Department of the Interior; Scott Blake

72

DOE Encourages Utility Sector Nominations to Commerce Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and network reliability issues. Last week, the Department of Commerce's National Telecommunications and Information Administration announced that it is seeking nominations for its...

73

A Multiattribute Utility Analysis of Sites Nominated For Characterizat...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

A Multiattribute Utility Analysis of Sites Nominated For Characterization For the First Radioactive Waste Repository - A Decision Aiding Methodology A Multiattribute Utility...

74

Open Nominations Call - Energy Department Employees, Join the...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nominations Call - Energy Department Employees, Join the Women @ Energy Series Dot Harris Dot Harris Director, Office of Economic Impact and Diversity In honor of Women's...

75

DOE Encourages Utility Sector Nominations to the Federal Communication...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Utility Sector Nominations to the Federal Communications Commission's Communications, Security, Reliability, and Interoperability Council March 29, 2011 - 5:22pm Addthis...

76

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

77

High Voltage Safety Act | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High Voltage Safety Act High Voltage Safety Act High Voltage Safety Act < Back Eligibility Commercial Construction Developer General Public/Consumer Industrial Installer/Contractor Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Safety and Operational Guidelines Siting and Permitting The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage electric lines by providing that no work shall be done in the vicinity of such lines unless and until the owner or operator thereof has been notified of such work and has taken the appropriate safety measures. The Georgia Public Service Commission requires

78

NOMINATION FORM 2010 Distinguished Texan in Agriculture Award  

E-Print Network (OSTI)

NOMINATION FORM 2010 Distinguished Texan in Agriculture Award Texas A&M AgriLife The Texas A/her contributions on behalf of the Texas agricultural industry and community (information may be submitted:__________________________________________________________ ________________________________________________________________________ RETURN NOMINATIONS TO 2010 Distinguished Texan in Agriculture Selection Advisory Committee c/o Office

79

2011 NOMINATIONS REPORT As Past President of the University of Saskatchewan Alumni Association, Chair of the Nominations Committee and Chair  

E-Print Network (OSTI)

2011 NOMINATIONS REPORT As Past President of the University of Saskatchewan Alumni Association of Saskatchewan Alumni Association Board of Directors: The Nominations Committee hereby recommends of Saskatchewan Alumni Association's 95th Annual General Meeting on June 16, 2011: For one year terms to begin

Saskatchewan, University of

80

Distinguished Alumni Awards Nomination Form 2008  

E-Print Network (OSTI)

________________________________________________________ Business Phone ______________________ Home Phone _____________________ Cell Phone _________________E Drive Salt Lake City, UT 84112 Phone: 581-6995 FAX: 581-3711 Nominee Information Name _______________________________________ Phone_______________________________ Company

Capecchi, Mario R.

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Constant voltage ultracapacitor  

Science Journals Connector (OSTI)

Ultracapacitors have attracted lots of attention recently due to their growing use in hybrid vehicles and in energy storage applications for the smart grid. A very undesirable feature of ultracapacitors is the fact that the voltage drops as the capacitor is discharged. DC-DC converters are employed at present to convert the voltage of the ultracapacitor to constant voltage; however these converters typically do not operate if the voltage of the ultracapacitor drops below 1?V. In addition DC-DC converters suffer from well-known size/efficiency tradeoffs. This paper introduces a novel new ultracapacitor that is characterized by constant voltage. The new ultracapacitor does not utilize familiar energy conversion principles. Rather operation depends on an embedded electromechanical system that actually alters the capacitance of the ultracapacitor as the device is discharged. Due to a simple proportionality relationship between charge capacitance and voltage the voltage remains constant. Theoretical and experimental investigations have shown that the embedded mechanism for altering the capacitance has an efficiency of 99% or higher.

Ezzat G. Bakhoum

2012-01-01T23:59:59.000Z

82

Voltage balanced multilevel voltage source converter system  

DOE Patents (OSTI)

A voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

83

Voltage balanced multilevel voltage source converter system  

DOE Patents (OSTI)

Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-07-01T23:59:59.000Z

84

Substation voltage upgrading  

SciTech Connect

Substation voltage uprating, i.e., conversion of a substation from a lower rated voltage to a higher rated voltage without a complete substation rebuild, can lead to excellent economic benefits. Utilization of the old substation layout and/or the existing equipment, to some extent, is the practical objective of such an uprating. The objective of this project was to assess the opportunities for substation uprating in the industry, to establish feasibility for such uprating and to study methods for accomplishing it. The final aim of the project was to provide guidance to utilities interested in uprating. 56 refs., 41 figs., 18 tabs.

Panek, J.; Elahi, H.; Sublich, M. (General Electric Co., Schenectady, NY (USA). Systems Development and Engineering Dept.)

1989-08-01T23:59:59.000Z

85

High voltage DC power supply  

DOE Patents (OSTI)

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

Droege, T.F.

1989-12-19T23:59:59.000Z

86

High voltage DC power supply  

DOE Patents (OSTI)

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

Droege, Thomas F. (Batavia, IL)

1989-01-01T23:59:59.000Z

87

Nominate An Inspirational STEM Teacher for the Nation's Highest Honors |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nominate An Inspirational STEM Teacher for the Nation's Highest Nominate An Inspirational STEM Teacher for the Nation's Highest Honors Nominate An Inspirational STEM Teacher for the Nation's Highest Honors February 8, 2013 - 1:04pm Addthis President Barack Obama talks with Presidential Awards for Excellence in Mathematics and Science Teaching winners in the State Dining of the White House January 6, 2010. (Official White House Photo by Chuck Kennedy) President Barack Obama talks with Presidential Awards for Excellence in Mathematics and Science Teaching winners in the State Dining of the White House January 6, 2010. (Official White House Photo by Chuck Kennedy) How can I participate? The 2013 Awards will honor mathematics and science (including computer science) teachers working in grades 7-12. Nominations close on

88

A Multiattribute Utility Analysis of Sites Nominated For Characterization  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

A Multiattribute Utility Analysis of Sites Nominated For A Multiattribute Utility Analysis of Sites Nominated For Characterization For the First Radioactive Waste Repository - A Decision Aiding Methodology A Multiattribute Utility Analysis of Sites Nominated For Characterization For the First Radioactive Waste Repository - A Decision Aiding Methodology Summary In December 1984, the Department of Energy (DOE) published draft environmental assessments (EAs) to support the proposed nomination of five sites and the recommendation of three sites for characterization for the first radioactive-waste repository. A chapter common to all the draft EAs (Chapter 7) presented rankings of the five sites against the postclosure and the preclosure technical siting guidelines. To determine which three sites appeared most favorable for recommendation for characterization,

89

Do parties still matter? : the politics of gubernatorial nominations  

E-Print Network (OSTI)

Who controls the nomination in gubernatorial elections? This dissertation seeks to answer this simple question. Parties have classically been the organizations held responsible for throwing their collective effort behind ...

Cobb, Rachael V

2006-01-01T23:59:59.000Z

90

DOE Under Secretary Nomination Announcement | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Under Secretary Nomination Announcement Under Secretary Nomination Announcement DOE Under Secretary Nomination Announcement March 12, 2009 - 12:00am Addthis WASHINGTON, DC - Today, President Barack Obama announced his intent to nominate the following individuals to key administration posts: Demetrios Marantis, Nominee for Deputy United States Trade Representative; Kristina M. Johnson, Nominee for Under Secretary of Energy; Gina McCarthy, Nominee for Assistant Administrator for Air and Radiation, Environmental Protection Agency; and Ronald H. Weich, Nominee for Assistant Attorney General, Office of Legislative Affairs, Department of Justice. President Obama said, "Each of these individuals brings a unique talent and dedication to the causes we are tackling everyday in my administration. Together they bring decades of public service and diverse backgrounds that

91

Agency Energy Coordinators for Award Nominations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Agency Energy Coordinators for Award Nominations Agency Energy Coordinators for Award Nominations Agency Energy Coordinators for Award Nominations October 7, 2013 - 4:41pm Addthis Federal agency energy coordinators handle all nominations for the Federal Energy and Water Management Awards. Contact your agency energy coordinator well in advance of all award deadlines to learn about internal submission processes. Don Juhasz Defense Logistics Agency 703-767-3537 Jerard Butler General Services Administration 202-401-0855 Mark Ewing General Services Administration 202-708-9296 Wayne Thalasinos National Aeronautics and Space Administration 202-358-3811 Mark Sprouse National Archives and Records Administration 301-837-3019 David Hauk Smithsonian Institution 202-633-1537 Leslie Ford Social Security Administration 410-594-0111

92

Low-voltage gyrotrons  

SciTech Connect

For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5-10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%-2% in the submillimeter wavelength region).

Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S. [Institute of Applied Physics RAS, N. Novgorod 603600 (Russian Federation); Nusinovich, G. S. [IREAP, University of Maryland, College Park, Maryland 20742-3511 (United States)

2013-03-15T23:59:59.000Z

93

Integrated, Low Voltage, DynamicallyIntegrated, Low Voltage, Dynamically Adaptive BuckAdaptive Buck--Boost ConverterBoost Converter  

E-Print Network (OSTI)

Improvement in battery life Low voltage Single cell operation (Li-ion/NiCd/NiMH/Fuel Cell) Integrated Linearity degradation #12;55Georgia Tech Analog Consortium Biranchinath Sahu School of Electrical

Rincon-Mora, Gabriel A.

94

Voltage controlled current source  

DOE Patents (OSTI)

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, Gregory M. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

95

High-voltage engineering  

E-Print Network (OSTI)

High-voltage engineering covers the application, the useful use and proper working of high voltages and high fields. Here we give some introductory examples, i.e., ‘septa’ and ‘kicker’ at the Large Hadron Collider (14 TeV), the Super Proton Synchrotron (450 GeV) and the Proton Synchrotron (26 GeV) accelerators as found at the European Orginization for Nuclear Research (CERN) today. We briefly cover the theoretical foundation (Maxwell equations) and aspects of numerical field simulation methods. Concepts relating to electrical fields, insulation geometry and medium and breakdown are introduced. We discuss ways of generating high voltages with examples of AC sources (50/60 Hz), DC sources, and pulse sources. Insulation and breakdown in gases, liquids, solids and vacuum are presented, including Paschen’s law (breakdown field and streamer breakdown). Applications of the above are discussed, in particular the general application of a transformer. We briefly discuss measurement techniques of partial disch...

Gaxiola, E

2006-01-01T23:59:59.000Z

96

Effects of Mg composition on open circuit voltage of Cu2OMgxZn1xO heterojunction solar cells  

E-Print Network (OSTI)

(ZnO) Cuprous oxide (Cu2O) Solar cells Electrodeposition MOCVD (metal-organic chemical vapor solar cells, where Ag and FTO are used as top and bottom electrodes, respectively. An enhancement on the MgxZn1�xO (x¼10%) based solar cell. & 2011 Elsevier B.V. All rights reserved. 1. Introduction Zn

Garfunkel, Eric

97

4-28-09_Final_Testimony_(Triay)_(Nomination).pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8, 2009 8, 2009 Good morning, Mr. Chairman, Senator McCain, members of the Committee. It is a great honor to appear before you today as President Obama's nominee to be the Assistant Secretary for Environmental Management at the United States Department of Energy. I thank Secretary Chu and President Obama for their support and confidence in recommending and nominating me. I also thank the Committee for considering my nomination. I would like to introduce my husband of 24 years, Dr. John Hall, and his parents Mr. and Mrs. Harvey Hall, who are with me here today. In 1961, when my parents fled Cuba's Communist regime and went into exile with a three- year-old daughter and nothing but their dreams for a better life and their love for freedom, it would have been impossible to believe that their daughter would ever be nominated by the

98

Improving the low voltage ride through of doubly fed induction generator during intermittent voltage source converter faults  

Science Journals Connector (OSTI)

The impact of different voltage source converter (VSC) faults on the low voltage ride through (LVRT) capability of the doubly fed induction generator (DFIG) is also investigated. Faults such as fire-through of the VSC switches and short circuit across the DC-link capacitor are considered in this paper. The impact of internal VSC faults when they occur within the grid side converter (GSC) and rotor side converter is investigated. A proper static synchronous compensator (STATCOM) controller to mitigate the effects of these faults is proposed. The DFIG compliance with numerous and recently released LVRT grid codes under these faults with and without the STATCOM is examined and compared. Simulation results indicate that these types of faults have a severe impact on the DFIG voltage profile especially when these faults occur in the GSC. This is attributed to the fact that the GSC directly regulates the point of common coupling (PCC) voltage. Moreover the proposed controller is capable of bringing the voltage profile at the PCC to the nominal steady state level and hence maintaining the connection of the wind turbine during the various studied faults.

H. R. Pota

2013-01-01T23:59:59.000Z

99

DOE Encourages Utility Sector Nominations to the Federal Communications  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

the Federal the Federal Communications Commission's Communications, Security, Reliability, and Interoperability Council DOE Encourages Utility Sector Nominations to the Federal Communications Commission's Communications, Security, Reliability, and Interoperability Council March 29, 2011 - 5:22pm Addthis Because of the role communications technologies will play in the evolution toward a smarter national grid, DOE recommended in its October 2010 report, The Communications Requirements of Smart Grid Technologies, that members of the utility sector become more engaged in the federal advisory committees that consider key policy issues related to the Smart Grid, including the reliability of communications networks. Last week, the Federal Communications Commission announced that it is seeking nominations

100

High voltage pulse conditioning  

DOE Patents (OSTI)

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

1990-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

STUDENT EMPLOYEE OF THE YEAR AWARD NOMINATION FORM  

E-Print Network (OSTI)

STUDENT EMPLOYEE OF THE YEAR AWARD NOMINATION FORM Nominees must be full-time, undergraduate, degree-seeking students and have at least one semester of employment as a student worker) for the University of Memphis as paid, student assistants. Generally student workers may be classified as "Work

Dasgupta, Dipankar

102

UNIVERSITY OF SASKATCHEWAN NOMINATION TO THE UNIVERSITY OF SASKATCHEWAN SENATE  

E-Print Network (OSTI)

UNIVERSITY OF SASKATCHEWAN NOMINATION TO THE UNIVERSITY OF SASKATCHEWAN SENATE The University of Saskatchewan Act 1995 (24.3) provides for membership on the University of Saskatchewan Senate by professional to the social, economic and cultural welfare of Saskatchewan; and (b) have a demonstrated interest in furthering

Saskatchewan, University of

103

Peculiarities of a method for ex-reactor heating of electrodes and obtaining voltage-current characteristics of multi-cell thermionic fuel elements  

SciTech Connect

The paper discusses principle of operation and applications of a pulse method of heating multi-cell thermionic fuel elements. Some experimental results are given for a cylindrical single-cell thermionic energy converter that simulates conditions close to that of multi-cell TFE operation. Basic requirements for technical parameters are stated that should be observed when testing TFE on thermal facilities. The means to improve the method are described, including both a computer-aided experiment and modifications in individual components of the test facility. {copyright} {ital 1996 American Institute of Physics.}

Kalandarishvili, A.G. [Sukhumi Institute of Physics and Engineering, Tbilisi 380008 Republic of (Georgia); Drozdov, A.A. [RRC ``Kurchatov Institute``, Moscow 123182 (Russia); Stepennov, B.S. [INERTEK, Moscow 123182 (Russia)

1996-03-01T23:59:59.000Z

104

High Voltage Electrolytes for Li-ion Batteries | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electrolytes for Li-ion Batteries High Voltage Electrolytes for Li-ion Batteries 2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and...

105

Voltage Fade, an ABR Deep Dive Project: Status and Outcomes  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Budget * Voltage Fade project * 3,900K Barriers * Calendarcycle life of lithium-ion cells being developed for PHEV and EV batteries that meet or exceed DOEUSABC goals Partners...

106

Charge-pump voltage converter  

DOE Patents (OSTI)

A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

Brainard, John P. (Albuquerque, NM); Christenson, Todd R. (Albuquerque, NM)

2009-11-03T23:59:59.000Z

107

Analysis of Hippocampal Cell Proliferation, Survival, and Neuronal Morphology in P/Q-Type Voltage-Gated Calcium Channel Mutant Mice  

E-Print Network (OSTI)

regulates important Ca2+-dependent neuronal processes including neurotransmitter release and synaptogenesis, we assessed effects of these mutations on hippocampus volume, neuronal density, neuronal morphology of hippocampal pyramidal cells in adult (six...

Nigussie, Fikru

2013-01-16T23:59:59.000Z

108

Vehicle Technologies Office Merit Review 2014: High Energy Density Li-ion Cells for EV’s Based on Novel, High Voltage Cathode Material Systems  

Energy.gov (U.S. Department of Energy (DOE))

Presentation given by Farasis Energy, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high energy density Li...

109

Ignition distributor voltage generator  

SciTech Connect

This patent describes a voltage pulse generator and ignition distributor comprising, a base, a shaft rotatably supported by the base, a distributor cap supported by the base having a center electrode and circumferentially spaced outer electrodes. The pulse generator and ignition distribution also include a first rotor driven by the shaft formed of electrical insulating material having electrically conductive means connected to the center terminal and a portion that rotates past the outer electrodes. The portion of the electrically conductive means that rotates past the outer electrodes is spaced from the outer electrodes to form a gap therebetween. A voltage pulse generator comprises a second rotor driven by the shaft, at least one permanent magnet and an annular pickup coil supported by the base. The pickup coil has inner turns and outer turns, the beginning turn of the inner turns connected to a first lead and the last turn of the outer turns connected to a second lead, the outer turns enclosing the inner turns. The pickup coil also has a circuit connected directly between the second lead and ground which is operative to provide a direct conductive path to ground for high frequency energy capacitively coupled to the outer turns from the gap discharge between the electrically conductive means of the first rotor and an outer electrode, the outer turns forming a grounded shield for the inner turns.

Boyer, J.A.

1986-11-04T23:59:59.000Z

110

4-23-09_Final_Nomination_Testimony_(Triay).pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3, 2009 3, 2009 Good afternoon, Mr. Chairman, Senator Murkowski, members of the Committee. It is a great honor to appear before you today as President Obama's nominee to be the Assistant Secretary for Environmental Management at the United States Department of Energy. I thank Secretary Chu and President Obama for their support and confidence in recommending and nominating me. I also thank the Committee for considering my nomination. I would like to introduce my husband of 24 years, Dr. John Hall, and his parents Mr. and Mrs. Harvey Hall, who are with me here today. In 1961, when my parents fled Cuba's Communist regime and went into exile with a three- year-old daughter and nothing but their dreams for a better life and their love for freedom, it

111

4-23-09_Final_Nomination_Testimony_(Koonin).pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Steven E. Koonin Steven E. Koonin Under Secretary for Science Designee Senate Committee on Energy and Natural Resources April 23, 2009 Chairman Bingaman, Senator Murkowski, members of the Committee, I am honored to appear before you as President Obama's nominee for Under Secretary for Science in the Department of Energy. With me this afternoon are my wife Laurie, who has been my companion and support for 39 years, and the second of our three children, Alyson, a junior at the University of Richmond. As you consider my nomination, I thought it would be useful for me to say something about myself beyond the bare biographical facts, something about my perceptions of Science in the Department of Energy, and about what I hope to accomplish if my nomination is confirmed.

112

Process Options for Nominal 2-K Helium Refrigeration System Designs  

SciTech Connect

Nominal 2-K helium refrigeration systems are frequently used for superconducting radio frequency and magnet string technologies used in accelerators. This paper examines the trade-offs and approximate performance of four basic types of processes used for the refrigeration of these technologies; direct vacuum pumping on a helium bath, direct vacuum pumping using full or partial refrigeration recovery, cold compression, and hybrid compression (i.e., a blend of cold and warm sub-atmospheric compression).

Peter Knudsen, Venkatarao Ganni

2012-07-01T23:59:59.000Z

113

Nominal symbols and their contribution to selected Guardian essays  

E-Print Network (OSTI)

: Dr. Harry P. Kroitor Nominal symbols were commonly used in periodical essays during the seventeenth and eighteenth centuries and the Guardian, written primarily by Sir Richard Steele and Joseph Addison, is no exception. Characters... times, to eighteenth-century British essayists, the name often made the man. In the Guardian, a series of 175 essays presented by the controlling persona Nestor Ironside and written by Sir Richard Steele, Joseph Addison, and some...

Dunsford, Deborah Williams

1987-01-01T23:59:59.000Z

114

Price of Everett, MA Natural Gas LNG Imports from Egypt (Nominal...  

Gasoline and Diesel Fuel Update (EIA)

Egypt (Nominal Dollars per Thousand Cubic Feet) Price of Everett, MA Natural Gas LNG Imports from Egypt (Nominal Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3...

115

Price of Cove Point, MD Natural Gas LNG Imports from Egypt (Nominal...  

U.S. Energy Information Administration (EIA) Indexed Site

Egypt (Nominal Dollars per Thousand Cubic Feet) Price of Cove Point, MD Natural Gas LNG Imports from Egypt (Nominal Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2...

116

Price of Gulf of Mexico Natural Gas LNG Imports (Nominal Dollars...  

Gasoline and Diesel Fuel Update (EIA)

(Nominal Dollars per Thousand Cubic Feet) Price of Gulf of Mexico Natural Gas LNG Imports (Nominal Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3 Year-4...

117

Spark-safe low-voltage detonator  

DOE Patents (OSTI)

A column of explosive in a low-voltage detonator which makes it spark-safe ncludes an organic secondary explosive charge of HMX in the form of a thin pad disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to an electrical ignition device at one end of the bore. The pad of secondary charge has an axial thickness within the range of twenty to thirty percent of its diameter. The explosive column also includes a first explosive charge of CP disposed in the housing bore in the ignition region of the explosive column next to the secondary charge pad on a side opposite from the ignition device. The first CP charge is loaded under sufficient pressure, 25 to 40 kpsi, to provide mechanical confinement of the pad of secondary charge and physical coupling thereof with the ignition device. The explosive column further includes a second explosive charge of CP disposed in the housing bore in a transition region of the explosive column next to the first CP charge on a side opposite from the pad of secondary charge. The second CP charge is loaded under sufficient pressure, about 10 kpsi, to allow occurrence of DDT. The first explosive CP charge has an axial thickness within the range of twenty to thirty percent of its diameter, whereas the second explosive CP charge contains a series of increments (nominally 4) each of which has an axial thickness-to-diameter ratio of one to two.

Lieberman, Morton L. (Albuquerque, NM)

1989-01-01T23:59:59.000Z

118

Planning of distribution networks for medium voltage and low voltage.  

E-Print Network (OSTI)

??Determination of the placement and rating of transformers and feeders are the main objective of the basic distribution network planning. The bus voltage and the… (more)

Ziari, Iman

2011-01-01T23:59:59.000Z

119

E-Print Network 3.0 - affects voltage-gated calcium Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

modulate neuronal voltage-gated calcium cur- rents, we performed a whole-cell patch... that hippocampal neurons in an astrocyte-enriched environment show augmentation of...

120

Substation voltage upgrading  

SciTech Connect

This report addresses specific issues to support sound yet not unduly conservative uprating practices for substations. The main parts of the report cover the insulation withstand and overvoltage protection aspects, environmental measurements, reliability criteria, and industry experience. First the insulation design concerns are addressed. Substation stress by a backflashover of the line insulation due to lightning in the vicinity of the substation is recognized as a critical stress. A representative part of a 550 kV BIL substation was erected at the EPRI High Voltage Transmission Research Center, where also a special test circuit was assembled to produce a fast front, slow tail (0.2/200 {mu}s) wave. The substation as well as some special configurations were tested for line-to-ground and line-to-line withstand. Computer studies were performed to complement the test results. A number of important conclusions was reached. The most prominent result in that the high frequency oscillations, as caused by reflections within the substation, do not effect the Critical Flashover Voltage (CFO). The present practice, based on the highest peak is therefore very conservative. The slow tail of the wave appears to dictate the CFO. An arrester model for computer studies to represent very fast as well as slow phenomena was derived. It is based on full scale arrester test data, made available in this project. The computer program to calculate arrester model parameters is also a part of the report. The electric environmental measurements are reported for the tested substation at the HVTRC and for the uprated substation of Public Service Company of Colorado, both before and after the uprating. The performance is satisfactory when corona free hardware is used. Insulation design criteria are analyzed based on substation reliability, the system viewpoint and consequences of the failure. Utility experience with uprated substations is reviewed.

Panek, J.; Elahi, H.; Lux, A.; Imece, A.F. (General Electric Co., Schenectady, NY (United States). Power Systems Engineering Dept.); LaPanse, R.A.; Stewart, J.R. (Public Service Co. of Colorado, Denver, CO (United States))

1992-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

ABBGroup-1-High voltage lab  

E-Print Network (OSTI)

;©ABBGroup-3- 3-Sep-07 Where does one use circuit breakers? High voltage (HV) circuit breakers are keyA DISTRIBUTION MEDIUM AND LOW VOLTAGE HV circuit breakers #12;©ABBGroup-4- 3-Sep-07 When a breaker fails to interrupt the current... Fault arc at a disconnector Fault arc in a substation #12;©ABBGroup-5- 3-Sep-07

Basse, Nils Plesner

122

Temperature controlled high voltage regulator  

DOE Patents (OSTI)

A temperature controlled high voltage regulator for automatically adjusting the high voltage applied to a radiation detector is described. The regulator is a solid state device that is independent of the attached radiation detector, enabling the regulator to be used by various models of radiation detectors, such as gas flow proportional radiation detectors.

Chiaro, Jr., Peter J. (Clinton, TN); Schulze, Gerald K. (Knoxville, TN)

2004-04-20T23:59:59.000Z

123

Nomination & Selection Guidelines | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Nomination & Selection Guidelines Nomination & Selection Guidelines The Ernest Orlando Lawrence Award Lawrence Award Home Nomination & Selection Guidelines Award Laureates Ceremony The Life of Ernest Orlando Lawrence Contact Information The Ernest Orlando Lawrence Award U.S. Department of Energy SC-2/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-9395 E: lawrence.award@science.doe.gov Nomination & Selection Guidelines Print Text Size: A A A RSS Feeds FeedbackShare Page Jump to: Nomination Guidelines | Lawrence Award Category Descriptions | Lawrence Award Assessment Criteria, Merit Review, and Selection | Preparation of Nomination Materials | Additional Information The 2013 Ernest Orlando Lawrence Award Nomination Guidelines The Ernest Orlando Lawrence Award is bestowed by the Secretary of the U.S.

124

Low voltage nonprimary explosive detonator  

DOE Patents (OSTI)

A low voltage, electrically actuated, nonprimary explosive detonator is disclosed wherein said detonation is achieved by means of an explosive train in which a deflagration-to-detonation transition is made to occur. The explosive train is confined within a cylindrical body and positioned adjacent to low voltage ignition means have electrical leads extending outwardly from the cylindrical confining body. Application of a low voltage current to the electrical leads ignites a self-sustained deflagration in a donor portion of the explosive train which then is made to undergo a transition to detonation further down the train.

Dinegar, Robert H. (Los Alamos, NM); Kirkham, John (Newbury, GB2)

1982-01-01T23:59:59.000Z

125

Definition: Automated Voltage Regulators | Open Energy Information  

Open Energy Info (EERE)

Regulators Regulators Jump to: navigation, search Dictionary.png Automated Voltage Regulators Voltage regulators are transformers that can increase or decrease the voltage on a distribution circuit to help keep the voltage within a pre-determined band. Unlike capacitor banks, voltage regulators cannot adjust power factor. These devices typically monitor the voltage at the location where they are connected, and compare it to a programmed set point. If the voltage deviates too far from the set point, the voltage regulator can increase or decrease its output voltage by moving the tap on the secondary side up or down. An automated voltage regulator can operate with remote control signals, or in concert with other area voltage control devices, to help regulate distribution voltage in a coordinated fashion.

126

Saving Megawatts with Voltage Optimization  

E-Print Network (OSTI)

that had been installed at several electric utility distribution substations in the U.S. and Canada. These systems, being operated in Conservation Voltage Regulation mode, have provided significant energy conservation where they have been installed...

Wilson, T.; Bell, D.

2010-01-01T23:59:59.000Z

127

Nickel-hydrogen voltage-efficiency model  

SciTech Connect

A model for providing voltage vs. current relationships and coulombic efficiency has been developed applicable to Nickel-Hydrogen (NiH{sub 2}) batteries. The performance relationships can be used directly in dynamic electrical energy storage system models or customized by predicting the particular case of voltage as a function of applied current. The algorithm utilizes electrochemical models for competing cell reactions: a single Butler-Volmer equation for the main NiH{sub 2} reaction, and a Tafel relationship for oxygen generation. For the main NiH{sub 2} reaction, the dependence on state-of-charge is introduced via a Nerstian term containing concentrations of active materials present. Oxygen recombination and self-discharge are modeled as first order reactions. Model parameters are determined by a modified Marquardt algorithm to provide a best-fit of both voltage and pressure data to the physical model. The data fit is from electrical characterization tests which may include capacity measurements or repeated electrical cycling at specified depths-of-discharge or with particular regimens. It has been found that test performance data covering a wide domain of the independent variables (temperature, current, and state-of-charge) will produce a well-behaved model.

Hafen, D.P.; Armantrout, J.D. [Lockheed Martin Missiles and Space, Sunnyvale, CA (United States)

1996-12-31T23:59:59.000Z

128

Nomination & Selection Guidelines | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Nomination & Selection Guidelines Nomination & Selection Guidelines The Enrico Fermi Award Fermi Award Home Nomination & Selection Guidelines Award Laureates Ceremony The Life of Enrico Fermi Contact Information The Enrico Fermi Award U.S. Department of Energy SC-2/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-9395 E: fermi.award@science.doe.gov Nomination & Selection Guidelines Print Text Size: A A A RSS Feeds FeedbackShare Page Jump to: Fermi Award Assessment Criteria, Merit Review, and Selection | Preparation of Nomination Materials The 2013 Enrico Fermi Award Nomination Guidelines The Enrico Fermi Award is bestowed by the President of the United States to an individual or individuals of international stature in recognition of exceptional scientific, technical, engineering, and/or management

129

5_5_09_Daniel_Poneman_Nomination.pdf  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Daniel B. Poneman Daniel B. Poneman Before the Committee on Energy and Natural Resources United States Senate May 5, 2009 Chairman Bingaman, Ranking Member Murkowski, and distinguished Members of the Committee, it is an honor and a privilege to appear before you today as President Obama's nominee to be Deputy Secretary of Energy. I would like to introduce my wife of nearly 25 years, Susan, and our sons, Michael and William. Our daughter, Claire, is away at college. I am grateful and humbled by the confidence that President Obama and Secretary Chu have expressed in me through this nomination. President Obama has articulated a clear and compelling vision of America's energy future - one that will transform our economy, protect our security, and save our planet from the worst impacts of climate change.

130

Nominal and Real Effective Exchange Rate for Bosnia and Herzegovina  

Science Journals Connector (OSTI)

This paper is presenting the overview of theoretic approach to Real Effective Exchange Rate (REER) and Nominal Effective Exchange Rate (NEER) indicators calculation for Bosnia and Herzegovina. Special attention is dedicated to statistical difficulties in calculation and still limited implementation of this approach in Bosnia and Herzegovina. NEER and REER indices are indicators by themselves that BH has to work a lot to improve its competitiveness position. It is a widely known statement that a country's competitiveness improves when the relative price of its tradable goods declines. BH mostly trade with its raw materials, which are mostly natural wealth of the county like wood, coal and aluminium, so this cannot be a long-term and permanent solution for the country.

Sandra Hlivnjak

2009-01-01T23:59:59.000Z

131

President-Elect Obama Nominates Dr. Steven Chu as Energy Secretary  

Energy.gov (U.S. Department of Energy (DOE))

President-elect Barack Obama has nominated Dr. Steven Chu, the current director of DOE's Lawrence Berkeley National Laboratory (LBNL), to be the next Secretary of Energy.

132

La morphologie du pluriel nominal du persan d’après la théorie Whole Word Morphology.  

E-Print Network (OSTI)

??Ce mémoire présente une étude de la morphologie de ce qui est généralement appelé le pluriel nominal du persan (parler de Téhéran) dans le cadre… (more)

Faghiri, Pegah

2010-01-01T23:59:59.000Z

133

Developing marketing strategies for a travel destination in the USA using the nominal group technique  

Science Journals Connector (OSTI)

This paper demonstrates the application of nominal grouping as a cost-effective qualitative alternative for developing marketing strategies. The nominal group technique was used to generate strategic directions for the Blue Ridge Parkway Association, a popular travel destination in the USA. Using a nominal group composed of industry experts, a SWOT analysis produced a list of strengths, weaknesses, opportunities and threats associated with the Blue Ridge Parkway. Next, potential market segments were identified and prioritised. Five marketing strategies emerged to reach the specified market segments. The study illustrates that the nominal group technique offers a cost and time-efficient qualitative alternative in making strategic decisions.

J. Dana Clark; Michael J. Dotson; Dinesh S. Dave

2010-01-01T23:59:59.000Z

134

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents (OSTI)

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

1994-06-28T23:59:59.000Z

135

Voltage, energy and power in electric circuits  

E-Print Network (OSTI)

Voltage, energy and power in electric circuits Science teaching unit #12;Disclaimer The Department-2008DVD-EN Voltage, energy and power in electric circuits #12;#12;© Crown copyright 2008 1The National Strategies | Secondary Voltage, energy and power in electric circuits 00094-2008DVD-EN Contents Voltage

Berzins, M.

136

Ancillary service details: Voltage control  

SciTech Connect

Voltage control is accomplished by managing reactive power on an alternating-current power system. Reactive power can be produced and absorbed by both generation and transmission equipment. Reactive-power devices differ substantially in the magnitude and speed of response and in their capital costs. System operators, transmission owners, generators, customers, power marketers, and government regulators need to pay close attention to voltage control as they restructure the U.S. electricity industry. Voltage control can affect reliability and commerce in three ways: (1) Voltages must be maintained within an acceptable range for both customer and power-system equipment to function properly. (2) The movement of reactive power consumes transmission resources, which limits the ability to move real power and worsens congestion. (3) The movement of reactive power results in real-power losses. When generators are required to supply excessive amounts of reactive power, their real-power production must be curtailed. These opportunity costs are not currently compensated for in most regions. Current tariffs are based on embedded costs. These embedded-cost tariffs average about $0.51/MWh, equivalent to $1.5 billion annually for the United States as a whole. Although this cost is low when compared with the cost of energy, it still aggregates to a significant amount of money. This report takes a basic look at why the power system requires reactive power (an appendix explains the fundamentals of real and reactive power). The report then examines the various types of generation and transmission resources used to supply reactive power and to control voltage. Finally it discusses how these resources are deployed and paid for in several reliability regions around the country. As the U.S. electricity industry is restructured, the generation, transmission, and system-control equipment and functions that maintain voltages within the appropriate ranges are being deintegrated.

Kirby, B.; Hirst, E.

1997-12-01T23:59:59.000Z

137

Three-dimensional multifluid simulations of ionospheric loss at Mars from nominal solar wind conditions  

E-Print Network (OSTI)

Three-dimensional multifluid simulations of ionospheric loss at Mars from nominal solar wind (2006), Three-dimensional multifluid simulations of ionospheric loss at Mars from nominal solar wind 2006; accepted 30 June 2006; published 21 September 2006. [1] Three-dimensional multifluid simulations

Harnett , Erika

138

Open Nominations Call- Energy Department Employees, Join the Women @ Energy Series  

Energy.gov (U.S. Department of Energy (DOE))

We are re-opening the call for nominations of outstanding women at the Department to share their story of their STEM career and offer advice and inspiration for others to explore a future in STEM. Send in your nomination of a Department of Energy employee to annemarie.horowitz@hq.doe.gov by Friday, June 5, 2014.

139

E. O. Lawrence Award Nominations | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

E. O. E. O. Lawrence Award Nominations News Featured Articles Science Headlines 2014 2013 2012 2011 2010 2009 2008 2007 2006 2005 Presentations & Testimony News Archives Contact Information Office of Science U.S. Department of Energy 1000 Independence Ave., SW Washington, DC 20585 P: (202) 586-5430 12.04.12 E. O. Lawrence Award Nominations The Office of Science is now accepting nominations for the 2013 E. O. Lawrence Award. Print Text Size: A A A Subscribe FeedbackShare Page Call for Nominations - 2013 E. O. Lawrence Award Nominations are sought for the 2013 E. O. Lawrence Awards beginning now through May 31, 2013. The outcome of the 2012 Lawrence Awards is anticipated to be announced soon. The Ernest Orlando Lawrence Award is bestowed by the Secretary of the U.S. Department of Energy to mid-career scientists and engineers in recognition

140

Enrico Fermi Award Nominations | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Enrico Fermi Enrico Fermi Award Nominations News Featured Articles Science Headlines 2014 2013 2012 2011 2010 2009 2008 2007 2006 2005 Presentations & Testimony News Archives Contact Information Office of Science U.S. Department of Energy 1000 Independence Ave., SW Washington, DC 20585 P: (202) 586-5430 12.04.12 Enrico Fermi Award Nominations The Office of Science is now accepting nominations for the 2013 Enrico Fermi Award. Print Text Size: A A A Subscribe FeedbackShare Page Call for Nominations - 2013 Enrico Fermi Award Nominations are sought for the 2013 Enrico Fermi Award beginning now through May 31, 2013. The outcome of the 2012 Fermi Award is anticipated to be announced soon. The Enrico Fermi Award is a Presidential award and one of the longest running and most prestigious science and technology awards given by the

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Statement from Energy Secretary Samuel W. Bodman on the Nomination of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

the Nomination the Nomination of Thomas P. D'Agostino as Under Secretary for Nuclear Security and Administrator of NNSA Statement from Energy Secretary Samuel W. Bodman on the Nomination of Thomas P. D'Agostino as Under Secretary for Nuclear Security and Administrator of NNSA May 17, 2007 - 12:55pm Addthis "Today the President announced his intention to nominate Thomas P. D'Agostino as Under Secretary for Nuclear Security and Administrator of the National Nuclear Security Administration (NNSA). Tom served as NNSA's Acting Administrator for three months and as Deputy Administrator for Defense Programs for the past fourteen months. In these roles, Tom has done an outstanding job and has earned my full confidence. With this nomination, we are making NNSA even stronger and I am eager to

142

A Review Of Water Contents Of Nominally Anhydrous Natural Minerals In The  

Open Energy Info (EERE)

A Review Of Water Contents Of Nominally Anhydrous Natural Minerals In The A Review Of Water Contents Of Nominally Anhydrous Natural Minerals In The Mantles Of Earth, Mars And The Moon Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: A Review Of Water Contents Of Nominally Anhydrous Natural Minerals In The Mantles Of Earth, Mars And The Moon Details Activities (0) Areas (0) Regions (0) Abstract: Olivine, pyroxene and garnet are nominally anhydrous but can accommodate tens to hundreds of parts per million (ppm) H2O or "water" in the form of protons incorporated in defects in their mineral structure. This review concerns the amount of water in nominally anhydrous minerals from mantle and mantle-derived rocks: peridotites, eclogites, megacrysts, basalts and kimberlites. Trends between internal and external parameters

143

ABBGroup-1-High voltage lab  

E-Print Network (OSTI)

A DISTRIBUTION MEDIUM AND LOW VOLTAGE HV circuit breakers #12;©ABBGroup-4- 3-Sep-07 When a breaker fails to interrupt the current... Fault arc at a disconnector Fault arc in a substation #12;©ABBGroup-5- 3-Sep-07/costs A detailed understanding of arc physics and fluid dynamics is necessary for the development of HV circuit

Basse, Nils Plesner

144

Current vs. Voltage Feedback Amplifiers  

E-Print Network (OSTI)

?' In most applications, the differences between current feedback (CFB) and voltage feedback (VFB) are not apparent. Today's CFB and VFB amplifiers have comparable performance, but there are cer- tain unique Performance · Feedback Freedom Aside from the well-known attribute of CFB amplifiers, gain

Lanterman, Aaron

145

Modulated voltage metastable ionization detector  

SciTech Connect

Metastable ionization detectors used for chromatographic analysis usually employa fixed high voltage for the ionization potential. For this reason, the operating range is limited to about three orders of magnitude. By use of the technique disclosed in the instant invention, operating ranges of about nine orders of magnitude are obtained. The output current from a metastable ionization detector (MID) is applied to a modulation voltage circuit. An adjustment is made to balance out the background current, and an output current, above background, is applied to an input of a strip chart recorder. For low level concentrations, i.e., low detected output current, the ionization potential will be at a maximum and the metastable ionization detector will operate at its most sensitive level. When the detected current from the metastable ionization detector increases above a predetermined threshold level, a voltage control circuit is activated which turns on a high voltage transistor which acts to reduce the ionization potential. The ionization potential applied to the metastable ionization detector is then varied so as to maintain the detected signal level constant. The variation in ionization potential is now related to the concentration fo the constituent and a representative amplitude is applied to another input of said strip chart recorder.

Carle, G. C.; Humphry, D. E.; Kojiro, D. R.

1985-08-27T23:59:59.000Z

146

Automatic Voltage Control of Electrical Systems  

Science Journals Connector (OSTI)

... to have complete automatic voltage regulation and it also has supervisory control for its main substations. By a careful application of automatically controlled regulators it is shown that the voltage ...

1934-01-20T23:59:59.000Z

147

Implications of Pulser Voltage Ripple  

SciTech Connect

In a recent set of measurements obtained by G. Kamin, W. Manning, A. Molvik, and J. Sullivan, the voltage waveform of the diode pulser had a ripple of approximately {+-}1.3% of the 65 kV flattop voltage, and the beam current had a larger corresponding ripple of approximately {+-}8.4% of the 1.5 mA average current at the location of the second Faraday cup, approximately 1.9 m downstream from the ion source. The period of the ripple was about 1 {mu}s. It was initially unclear whether this large current ripple was in fact a true measurement of the current or a spurious measurement of noise produced by the pulser electronics. The purpose of this note is to provide simulations which closely match the experimental results and thereby corroborate the physical nature of those measurements, and to provide predictions of the amplitude of the current ripples as they propagate to the end of linear transport section. Additionally analytic estimates are obtained which lend some insight into the nature of the current fluctuations and to provide an estimate of what the maximum amplitude of the current fluctuations are expected to be, and conversely what initial ripple in the voltage source is allowed, given a smaller acceptable tolerance on the line charge density.

Barnard, J J

2011-12-21T23:59:59.000Z

148

Onset voltage of corona on coated conductors  

SciTech Connect

This paper is aimed for investigating the effect of surface coating on the positive and negative onset voltages of corona from stressed conductor as a pre-requisite for onset-voltage calculation. The electric field is accurately calculated by the charge simulation technique. The calculated onset voltages agreed satisfactorily with those measured experimentally for bare conductors. The effect of coating-layer thickness and permittivity as well as conductor radius and height on the onset-voltage values is discussed.

Abdel-Salam, M. [Assiut Univ. (Egypt). Electrical Engineering Dept.; Abo-Shal, Y. [SCECO-East, Dammam (Saudi Arabia). Electrical Engineering Div.

1995-12-31T23:59:59.000Z

149

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Energy.gov (U.S. Department of Energy (DOE))

Presentation given by Seeo, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high-voltage solid polymer...

150

Low Cost SiOx-Graphite and High Voltage Spinel Cathode | Department...  

Office of Environmental Management (EM)

Cathode Low Cost SiOx-Graphite and High Voltage Spinel Cathode 2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and Peer Evaluation...

151

U.S. Nominal Cost per Dry Well Drilled (Thousand Dollars per...  

Annual Energy Outlook 2012 (EIA)

Dry Well Drilled (Thousand Dollars per Well) U.S. Nominal Cost per Dry Well Drilled (Thousand Dollars per Well) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6 Year-7...

152

U.S. Nominal Cost per Natural Gas Well Drilled (Thousand Dollars...  

Annual Energy Outlook 2012 (EIA)

Natural Gas Well Drilled (Thousand Dollars per Well) U.S. Nominal Cost per Natural Gas Well Drilled (Thousand Dollars per Well) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5...

153

U.S. Nominal Cost per Foot of Natural Gas Wells Drilled (Dollars...  

Annual Energy Outlook 2012 (EIA)

Natural Gas Wells Drilled (Dollars per Foot) U.S. Nominal Cost per Foot of Natural Gas Wells Drilled (Dollars per Foot) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6...

154

U.S. Nominal Cost per Foot of Crude Oil, Natural Gas, and Dry...  

Gasoline and Diesel Fuel Update (EIA)

Oil, Natural Gas, and Dry Wells Drilled (Dollars per Foot) U.S. Nominal Cost per Foot of Crude Oil, Natural Gas, and Dry Wells Drilled (Dollars per Foot) Decade Year-0 Year-1...

155

U.S. Nominal Cost per Crude Oil Well Drilled (Thousand Dollars...  

Annual Energy Outlook 2012 (EIA)

Oil Well Drilled (Thousand Dollars per Well) U.S. Nominal Cost per Crude Oil Well Drilled (Thousand Dollars per Well) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6 Year-7...

156

U.S. Nominal Cost per Foot of Crude Oil Wells Drilled (Dollars...  

Annual Energy Outlook 2012 (EIA)

Oil Wells Drilled (Dollars per Foot) U.S. Nominal Cost per Foot of Crude Oil Wells Drilled (Dollars per Foot) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6 Year-7 Year-8...

157

U.S. Nominal Cost per Crude Oil, Natural Gas, and Dry Well Drilled...  

Gasoline and Diesel Fuel Update (EIA)

Oil, Natural Gas, and Dry Well Drilled (Thousand Dollars per Well) U.S. Nominal Cost per Crude Oil, Natural Gas, and Dry Well Drilled (Thousand Dollars per Well) Decade Year-0...

158

The Psychology Society Award Nomination Form for the 2012 -2013 Academic Year  

E-Print Network (OSTI)

The Psychology Society Award Nomination Form for the 2012 - 2013 Academic Year The Psychology Society Award has been established by the students of the Psychology Society to encourage and support their fellow students

Oyet, Alwell

159

Nominations Now Open: Mid-Career Women in Clean Energy Awards  

Energy.gov (U.S. Department of Energy (DOE))

Nominations are now being accepted to honor mid-career women for outstanding work in clean energy. These annual awards are run by the MIT Energy Initiative (MITEI) as part of an overarching...

160

High voltage RF feedthrough bushing  

DOE Patents (OSTI)

Described is a multi-element, high voltage radio frequency bushing for trmitting RF energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.

Grotz, Glenn F. (Huntington Station, NY)

1984-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

A chlorophyll solar cell  

Science Journals Connector (OSTI)

A simple chlorophyll solar cell has been designed built and tested. A voltage output versus time curve has also been obtained. (AIP)

J. Christopher Ludlow

1982-01-01T23:59:59.000Z

162

Definition: Operating Voltage | Open Energy Information  

Open Energy Info (EERE)

Voltage Voltage Jump to: navigation, search Dictionary.png Operating Voltage The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related; also, the effective (root-mean-square) potential difference between any two conductors or between a conductor and the ground. The actual voltage of the circuit may vary somewhat above or below this value.[1] Related Terms system References ↑ Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Operating_Voltage&oldid=480559" Categories: Definitions ISGAN Definitions What links here Related changes

163

Wind Power Plant Voltage Stability Evaluation: Preprint  

SciTech Connect

Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

Muljadi, E.; Zhang, Y. C.

2014-09-01T23:59:59.000Z

164

High voltage load resistor array  

DOE Patents (OSTI)

A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

Lehmann, Monty Ray (Smithfield, VA)

2005-01-18T23:59:59.000Z

165

Group 3: Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect

Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-05-01T23:59:59.000Z

166

High Voltage Electrolyte for Lithium Batteries  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

battery using high voltage high energy cathode materials to enable large-scale, cost competitive production of the next generation of electric-drive vehicles. To...

167

E-Print Network 3.0 - astrocyte cell line Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

modulate neuronal voltage-gated calcium cur- rents, we performed a whole-cell patch... -culture with astrocytes can augment the magnitude of voltage-gated calcium...

168

Nominations open for $250,000 Multimedia Clean Energy prizes | OpenEI  

Open Energy Info (EERE)

Nominations open for $250,000 Multimedia Clean Energy prizes Nominations open for $250,000 Multimedia Clean Energy prizes Home > Groups > Utility Rate Graham7781's picture Submitted by Graham7781(1992) Super contributor 2 October, 2012 - 13:01 American Clean Skies Foundation clean energy Energy Visions Prize OpenEI WASHINGTON, D.C. (September 27, 2012) - Representatives of the $250,000 Energy Visions Prize (EVP) competition will attend the Cleanweb Hackathons in NYC, Houston and SXSW Eco in Austin to preview innovative clean energy apps and encourage nominations. The EVP rewards innovative software and video makers who advance clean energy solutions. Based on growing national interest in the competition, the prize sponsor, the American Clean Skies Foundation (ACSF), also announced that it has extended the submission deadline until December 14, 2012.

169

Variable current-voltage TPV device for use in a thermophotovoltaic energy conversion system  

DOE Patents (OSTI)

A front-side or back-side illuminated variable current-voltage thermophotovoltaic device comprises a support substrate; isolation layers disposed on the support substrate; a plurality of cells disposed on the isolation layers, each of the cells including a base layer and an emitter layer; an insulating member disposed between each of the cells configured to isolate each cell from adjacent cells; an ohmic contact configured to connect each cell to another cell in series; and a spectral control device disposed on top of the cells and/or on the bottom surface of the support substrate.

Charache, Greg W. (Clifton Park, NY); Baldasaro, Paul F. (Clifton Park, NY); Campbell, Brian C. (Scotia, NY)

2000-01-01T23:59:59.000Z

170

DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION  

E-Print Network (OSTI)

1 DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION In this paper the design and implementation of a fuzzy logic-based controller is described for regulating the output voltage of a synchronous generator. An automated fuzzy logic-based control strategy is presented

LaMeres, Brock J.

171

Development of High Voltage Electron Microscope  

Science Journals Connector (OSTI)

......Cockcroft Walton Type High Voltage Generator. O Power Line O Fig. 4...pressure in the tank to the atmospheric pressure by removing freon...pump using liquid nitrogen. Water buffer and liquid nitrogen...base plate of high voltage generator. Four poles stand on this......

Shinjiro KATAGIRI; Hirokazu KIMURA; Susumu OZASA; Kazumi SHIRAISHI

1969-01-01T23:59:59.000Z

172

Voltage regulation in linear induction accelerators  

DOE Patents (OSTI)

Improvement in voltage regulation in a Linear Induction Accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance.

Parsons, William M. (Santa Fe, NM)

1992-01-01T23:59:59.000Z

173

Voltage regulation in linear induction accelerators  

DOE Patents (OSTI)

Improvement in voltage regulation in a linear induction accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core is disclosed. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance. 4 figs.

Parsons, W.M.

1992-12-29T23:59:59.000Z

174

Limitations of High-Voltage Insulation  

Science Journals Connector (OSTI)

... materials such as impregnated paper. The important electrical properties of the materials used for the insulation of high-voltage circuits are conductivity and electric strength. The conductivity measures the ability ... a million times between themselves, but they are all classified as available for high-voltage insulation.

1938-01-08T23:59:59.000Z

175

Non-contact current and voltage sensor  

DOE Patents (OSTI)

A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

2014-03-25T23:59:59.000Z

176

Strongly nonlinear dynamics of electrolytes in large ac voltages Laurits Hjgaard Olesen,1,2  

E-Print Network (OSTI)

the results have been developed for over a century 1 . Current applications include energy storage; published 2 July 2010 We study the response of a model microelectrochemical cell to a large ac voltage of frequency comparable to the inverse cell relaxation time. To bring out the basic physics, we consider

177

Electrical coupling in proton exchange membrane fuel cell stacks: mathematical and computational modelling  

Science Journals Connector (OSTI)

......unique solution (the equations force all other cells to run at this...and voltage, V . The scaled fundamental voltage equation (21) forces the voltage to be constant...HODGMAN, C. (ed.) (1959) Handbook of Chemistry and Physics......

Peter Berg; Atife Caglar; Keith Promislow; Jean St-Pierre; Brian Wetton

2006-04-01T23:59:59.000Z

178

U.S. Nominal Cost per Foot of Dry Wells Drilled (Dollars per...  

Annual Energy Outlook 2012 (EIA)

Dry Wells Drilled (Dollars per Foot) U.S. Nominal Cost per Foot of Dry Wells Drilled (Dollars per Foot) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6 Year-7 Year-8 Year-9...

179

A Nominal Filter for Web Search Snippets: Using the Web to Identify Members of Latin  

E-Print Network (OSTI)

A Nominal Filter for Web Search Snippets: Using the Web to Identify Members of Latin America. This paper presents efforts aimed at using Natural Language Engineering (NLE) techniques to solve of three Latin American countries: Uruguay, Argentina and Colombia. An NLE system is under construction

Turner, William

180

DCU Research Ethics Advisers Schools and research centres nominate Research Ethics Advisers to fulfil the  

E-Print Network (OSTI)

DCU Research Ethics Advisers Schools and research centres nominate Research Ethics Advisers to fulfil the following functions in their respective units: Act as point of contact for the Research Ethics Committee, and for colleagues on research ethics issues Inform themselves on common issues of research

Humphrys, Mark

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Formalising the -calculus using Nominal Logic Jesper Bengtson and Joachim Parrow  

E-Print Network (OSTI)

of Information Technology, University of Uppsala, Sweden Abstract. We formalise the pi-calculus using the nominal an implementation in Isabelle/HOL. The purpose is to derive powerful induction rules for the semantics in order. This is a normal strategy for manual proofs about the pi-calculus, but that kind of hand waving has previously been

Flener, Pierre

182

University of Texas Department of Biomedical Engineering Spring/Summer Admissions Required Nomination Form  

E-Print Network (OSTI)

University of Texas Department of Biomedical Engineering Spring/Summer Admissions Required, condition for admission to the UT BME Ph.D. Program in the spring or summer term. A complete and on with Application Materials: Spring Admission -- October 1 Summer Admission -- March 1 The nominating UT BME GSC

Ghosh, Joydeep

183

Electro-optical voltage sensor head  

DOE Patents (OSTI)

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID)

1998-01-01T23:59:59.000Z

184

arXiv:1003.5447v2[cs.LO]14May2010 Relating Nominal and Higher-order  

E-Print Network (OSTI)

, nominal logic, higher-order abstract syn- tax This work has been supported by INRIA through the "Equipes]. Formalizing speci- fication based on higher-order abstract syntax requires a frame- work with devicesarXiv:1003.5447v2[cs.LO]14May2010 Relating Nominal and Higher-order Abstract Syntax Specifications

Paris-Sud XI, Université de

185

Z .Bioelectrochemistry and Bioenergetics 45 1998 316 Time course of transmembrane voltage induced by time-varying electric  

E-Print Network (OSTI)

Z .Bioelectrochemistry and Bioenergetics 45 1998 3­16 Time course of transmembrane voltage induced.rBioelectrochemistry and Bioenergetics 45 1998 3­164 Fig. 1. The model on which the calculations were based. The cell is a sphere

Ljubljana, University of

186

Researchers map atomic movements that trigger voltage fade in...  

NLE Websites -- All DOE Office Websites (Extended Search)

map atomic movements that trigger voltage fade in high-energy-density batteries January 22, 2015 Voltage and capacity curves from an LMR-NMC high-energy cathode show voltage fade...

187

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, R.S.

1985-08-05T23:59:59.000Z

188

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile. 2 figs.

Hawke, R.S.

1987-11-17T23:59:59.000Z

189

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, Ronald S. (Livermore, CA)

1987-01-01T23:59:59.000Z

190

Modular high voltage power supply for chemical analysis  

DOE Patents (OSTI)

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2010-05-04T23:59:59.000Z

191

Constant voltage electro-slag remelting control  

DOE Patents (OSTI)

A system for controlling electrode gap in an electro-slag remelt furnace has a constant regulated voltage and an electrode which is fed into the slag pool at a constant rate. The impedance of the circuit through the slag pool is directly proportional to the gap distance. Because of the constant voltage, the system current changes are inversely proportional to changes in gap. This negative feedback causes the gap to remain stable. 1 fig.

Schlienger, M.E.

1996-10-22T23:59:59.000Z

192

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...

193

Optimal Voltage Control of the Southern Norwegian Power Grid.  

E-Print Network (OSTI)

??This thesis contains the synthesis, analysis and simulation results of an automatic optimal voltage controller for the Southern Norwegian power grid. Currently the high voltage… (more)

Hannisdal, Erik Lundegaard

2011-01-01T23:59:59.000Z

194

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2013 DOE...

195

High voltage overhead long transmission line design and fault analysis.  

E-Print Network (OSTI)

??The goal of this project is to design a reliable high voltage overhead long transmission line that satisfies specific design criteria including voltage regulation, efficiency,… (more)

Elzain, Mohamed Ali

2011-01-01T23:59:59.000Z

196

NREL’s Grid Integration Lab Nominated for Prestigious Project Management Award  

Office of Energy Efficiency and Renewable Energy (EERE)

The new Energy Systems Integration Facility (ESIF) at the Energy Department’s National Renewable Energy Laboratory (NREL) received a nomination as one of three international finalists for the Project Management Institute (PMI) Project of the Year Award. Although the ESIF project team didn’t take home the top honor this year, we are proud of the accomplishments they made in bringing one of the most innovative new laboratories in the country from the drawing board to fruition.

197

Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics  

SciTech Connect

This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

Liu, E.; Bebic, J.

2008-02-01T23:59:59.000Z

198

Physical simulation study of dynamic voltage instability  

SciTech Connect

This paper presents a physical simulation of the dynamic behavior of voltage instability in an interconnected multimachine environment. The dynamic evolving process leading to eventual voltage collapse, the scenario of the progressive reactive support reduction resulting from the MXL protection relays, the OLTC operation, and the effect of switched-in capacitor banks are examined using physical facilities in the laboratory. The physical simulation results are also compared with digital simulation results. This physical investigation provides a reliable foundation for the effective development of assessment approaches and countermeasures.

Tso, S.K.; Zhu, T.X. [Univ. of Hong Kong (Hong Kong); Zeng, Q.Y. [Electric Power Research Inst., Beijing (China); Lo, K.L. [Univ. of Strathclyde, Glasgow (United Kingdom). Dept. of Electrical and Electrical Engineering

1995-12-31T23:59:59.000Z

199

The Influence of Catalysts on Discharge and Charge Voltages of Rechargeable Li–Oxygen Batteries  

E-Print Network (OSTI)

This study revealed the strong influence of carbon, Au/C, and Pt/C catalysts on the charge and discharge voltages of rechargeable Li–O[subscript 2] batteries. Li–O[subscript 2] single-cell measurements showed that Au/C had ...

Gasteiger, Hubert A.

200

Voltage-gated Ion Channels and Gating Modifier Toxins William A. Catterall,* Sandrine Cestle,  

E-Print Network (OSTI)

;2 Abstract Voltage-gated sodium, calcium, and potassium channels generate electrical signals required and a pore loop. Their pores are formed by the S5/S6 segments and the pore loop between them and are gated and participate in calcium signaling pathways in nonexcitable cells. Because of their importance in many aspects

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Electro-optic voltage sensor for sensing voltage in an E-field  

DOE Patents (OSTI)

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID); Renak, Todd W. (Idaho Falls, ID)

1999-01-01T23:59:59.000Z

202

Electro-optic high voltage sensor  

DOE Patents (OSTI)

A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal having at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

Davidson, James R. (Idaho Falls, ID); Seifert, Gary D. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

203

Distribution System Voltage Regulation by Distributed Energy Resources  

SciTech Connect

This paper proposes a control method to regulate voltages in 3 phase unbalanced electrical distribution systems. A constrained optimization problem to minimize voltage deviations and maximize distributed energy resource (DER) active power output is solved by harmony search algorithm. IEEE 13 Bus Distribution Test System was modified to test three different cases: a) only voltage regulator controlled system b) only DER controlled system and c) both voltage regulator and DER controlled system. The simulation results show that systems with both voltage regulators and DER control provide better voltage profile.

Ceylan, Oguzhan [ORNL; Liu, Guodong [ORNL; Xu, Yan [ORNL; Tomsovic, Kevin [University of Tennessee, Knoxville (UTK)

2014-01-01T23:59:59.000Z

204

Sacramento Area Voltage Support Environmental Impact Statement  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

E E R R A N E V A D A R E G I O N Sacramento Area Voltage Support DRAFT ENVIRONMENTAL IMPACT STATEMENT DRAFT ENVIRONMENTAL IMPACT STATEMENT DOE/EIS-0323 NOVEMBER 2002 COVER SHEET Title: Sacramento Area Voltage Support Draft Environmental Impact Statement (EIS) Lead Agency: Western Area Power Administration (Western) Location: Alameda, Contra Costa, Placer, Sacramento, San Joaquin, and Sutter Counties, State of California. EIS Number: DOE/EIS-0323 Contact: Ms. Loreen McMahon, Environmental Project Manager Western Area Power Administration Sierra Nevada Region 114 Parkshore Drive Folsom, CA 95630 (916) 353-4460 (916) 985-1936 fax email: mcmahon@wapa.gov Website: Information is also available on our website: www.wapa.gov Hotline: 1-877-913-4440 (toll-free) Abstract The Western Area Power Administration's Central Valley Project transmission system forms an integral part of

205

High voltage electric substation performance in earthquakes  

SciTech Connect

This paper examines the performance of several types of high voltage substation equipment in past earthquakes. Damage data is provided in chart form. This data is then developed into a tool for estimating the performance of a substation subjected to an earthquake. First, suggests are made about the development of equipment class fragility curves that represent the expected earthquake performance of different voltages and types of equipment. Second, suggestions are made about how damage to individual pieces of equipment at a substation likely affects the post-earthquake performance of the substation as a whole. Finally, estimates are provided as to how quickly a substation, at various levels of damage, can be restored to operational service after the earthquake.

Eidinger, J. [G and E Engineering Systems, Oakland, CA (United States); Ostrom, D. [Southern California Edison, Rosemead, CA (United States); Matsuda, E. [Pacific Gas and Electric, San Francisco, CA (United States)

1995-12-31T23:59:59.000Z

206

Superconducting Fault Current Limiter for Transmission Voltage  

Science Journals Connector (OSTI)

Within a collaboration of American Superconductor, Siemens, Nexans and Southern California Edison one electrical phase of a resistive superconducting fault current limiter for the 115 kV transmission voltage level has been designed and manufactured. The active part of the limiter consists of 63 bifilar coils made of 12 mm wide steel-stabilized YBCO conductor and is housed in a cryostat operated at 5 bar and 74 K. The first phase was completely assembled and successfully subjected to power switching tests and high voltage tests. The basic design of the system and the test results are reported. The work was funded in part by US-DOE under Contract Number DE-FC26-07NT43243.

Hans-Peter Kraemer; Wolfgang Schmidt; Hong Cai; Bruce Gamble; David Madura; Tim MacDonald; Joe McNamara; Walther Romanosky; Greg Snitchler; Nicolas Lallouet; Frank Schmidt; Syed Ahmed

2012-01-01T23:59:59.000Z

207

Electrical system architecture having high voltage bus  

DOE Patents (OSTI)

An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

2011-03-22T23:59:59.000Z

208

Low Voltage White Phosphorescent OLED Achievements  

Energy.gov (U.S. Department of Energy (DOE))

Universal Display Corporation (UDC) and its research partners at Princeton University and the University of Southern California have succeeded in developing a white phosphorescent OLED (PHOLED™) that achieved a record efficiency of 20 lumens per watt. This achievement is the result of the team's collaborative efforts to increase the efficiency of PHOLED lighting by focusing on two critical factors: lowering the drive voltages and increasing the amount of light extracted.

209

Classification of Voltage Sags Based on MPCA Models  

Science Journals Connector (OSTI)

In this paper, we introduce a new framework for classification of short duration voltage reductions in the area of Power Quality Monitoring using Multiway Principal Component Analysis (MPCA). Firstly, we recast the sags occurred in High Voltage (HV) ...

Abbas Khosravi; Joaquim Melendez; Joan Colomer

2007-06-01T23:59:59.000Z

210

A BIST Technique for RF Voltage-Controlled Oscillators  

Science Journals Connector (OSTI)

A built-in self-test (BIST) architecture is proposed for voltage-controlled oscillators (VCO) operating at multigigahertz frequencies. By utilizing a frequency divider and a frequency-to-voltage converter (FVC), the output frequency and tuning range ...

Hsieh-Hung Hsieh; Yen-Chih Huang; Liang-Hung Lu; Guo-Wei Huang

2007-10-01T23:59:59.000Z

211

Low voltage amplifier architecture for high speed switched capacitor circuits  

E-Print Network (OSTI)

This work concentrates on circuit realization of high speed and low voltage switched capacitor circuits, with emphasis on the operational transconductance amplifier (OTA). An overview of switched capacitor circuits is given. Speed and voltage...

Shankar, Asit

2012-06-07T23:59:59.000Z

212

Electro-optic voltage sensor head  

DOE Patents (OSTI)

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers.

Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Woods, Gregory K. (Cornelius, OR)

1999-01-01T23:59:59.000Z

213

Calmodulin and calcium differentially regulate the neuronal Nav1.1 voltage-dependent sodium channel  

SciTech Connect

Highlights: {yields} Both Ca{sup ++}-Calmodulin (CaM) and Ca{sup ++}-free CaM bind to the C-terminal region of Nav1.1. {yields} Ca{sup ++} and CaM have both opposite and convergent effects on I{sub Nav1.1}. {yields} Ca{sup ++}-CaM modulates I{sub Nav1.1} amplitude. {yields} CaM hyperpolarizes the voltage-dependence of activation, and increases the inactivation rate. {yields} Ca{sup ++} alone antagonizes CaM for both effects, and depolarizes the voltage-dependence of inactivation. -- Abstract: Mutations in the neuronal Nav1.1 voltage-gated sodium channel are responsible for mild to severe epileptic syndromes. The ubiquitous calcium sensor calmodulin (CaM) bound to rat brain Nav1.1 and to the human Nav1.1 channel expressed by a stably transfected HEK-293 cell line. The C-terminal region of the channel, as a fusion protein or in the yeast two-hybrid system, interacted with CaM via a consensus C-terminal motif, the IQ domain. Patch clamp experiments on HEK1.1 cells showed that CaM overexpression increased peak current in a calcium-dependent way. CaM had no effect on the voltage-dependence of fast inactivation, and accelerated the inactivation kinetics. Elevating Ca{sup ++} depolarized the voltage-dependence of fast inactivation and slowed down the fast inactivation kinetics, and for high concentrations this effect competed with the acceleration induced by CaM alone. Similarly, the depolarizing action of calcium antagonized the hyperpolarizing shift of the voltage-dependence of activation due to CaM overexpression. Fluorescence spectroscopy measurements suggested that Ca{sup ++} could bind the Nav1.1 C-terminal region with micromolar affinity.

Gaudioso, Christelle; Carlier, Edmond; Youssouf, Fahamoe [INSERM U641, Institut Jean Roche, Marseille F-13344 (France) [INSERM U641, Institut Jean Roche, Marseille F-13344 (France); Universite de la Mediterranee, Faculte de Medecine Secteur Nord, IFR 11, Marseille F-13344 (France); Clare, Jeffrey J. [Eaton Pharma Consulting, Eaton Socon, Cambridgeshire PE19 8EF (United Kingdom)] [Eaton Pharma Consulting, Eaton Socon, Cambridgeshire PE19 8EF (United Kingdom); Debanne, Dominique [INSERM U641, Institut Jean Roche, Marseille F-13344 (France) [INSERM U641, Institut Jean Roche, Marseille F-13344 (France); Universite de la Mediterranee, Faculte de Medecine Secteur Nord, IFR 11, Marseille F-13344 (France); Alcaraz, Gisele, E-mail: gisele.alcaraz@univmed.fr [INSERM U641, Institut Jean Roche, Marseille F-13344 (France) [INSERM U641, Institut Jean Roche, Marseille F-13344 (France); Universite de la Mediterranee, Faculte de Medecine Secteur Nord, IFR 11, Marseille F-13344 (France)

2011-07-29T23:59:59.000Z

214

Analysis and design of an electronic voltage ratchet  

E-Print Network (OSTI)

and decay. Impulse voltages are produced through the discharging of 0, capacitor into a shaping network consisting of resistors and a. capacitor as is shown in Figure 2. 9. The operation of the impulse generator is as follows. Capacitor Ci is charged from... voltage shaping network. as possible in order to reduce oscillations in the wavefront and wavetail portions of the impulse voltage [1). The impulse voltage generator requires a, highly charged capacitor or bank of capacitors. Capacitors may be charged...

Menendez, Jorge Carlos

2012-06-07T23:59:59.000Z

215

Electrochemical Characterization of Voltage Fade in LMR-NMC cells  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

oriented plate-like grains 1 m 6 Dean Miller Argonne Positive Electrode (made by Saft): 86 %wt Li 1.2 Ni 0.15 Mn 0.55 Co 0.1 O 2 (0.5Li 2 MnO 3 0.5LiNi 0.375 Mn 0.375 Co...

216

LM2907LM2917FrequencytoVoltageConverter February 1995  

E-Print Network (OSTI)

TL H 7942 LM2907LM2917FrequencytoVoltageConverter February 1995 LM2907 LM2917 Frequency to Voltage Converter General Description The LM2907 LM2917 series are monolithic frequency to voltage converters doubling for low ripple full input protection in two versions (LM2907-8 LM2917-8) and its output swings

Wedeward, Kevin

217

Low voltage vertical recording preamplifier for hard disk drives  

E-Print Network (OSTI)

. . . . . . . . . . . . . . . . . 4 2 Input drivers of the preamplifier along with the decoupling caps and parasitics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3 Voltage bias voltage sensing scheme . . . . . . . . . . . . . . . . . . . 8 4 Current bias current... sensing scheme . . . . . . . . . . . . . . . . . . 9 5 Current bias scheme which common mode sense voltage to DE . . . . 10 6 Decoupling the inputs of the differential pair using feedback . . . . . 11 7 Barkhausen noise...

Mellachervu, Ramachandra Murthy

2004-11-15T23:59:59.000Z

218

The Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions  

E-Print Network (OSTI)

that generates variable magnitude variable frequency output voltage from the ac utility line. It has high power voltage disturbance related performance issues of the MC drive. Since the MC is a direct frequencyThe Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions Jun-Koo Kang

Hava, Ahmet

219

Pattern recognition monitoring of PEM fuel cell  

DOE Patents (OSTI)

The CO-concentration in the H.sub.2 feed stream to a PEM fuel cell stack is monitored by measuring current and voltage behavior patterns from an auxiliary cell attached to the end of the stack. The auxiliary cell is connected to the same oxygen and hydrogen feed manifolds that supply the stack, and discharges through a constant load. Pattern recognition software compares the current and voltage patterns from the auxiliary cell to current and voltage signature determined from a reference cell similar to the auxiliary cell and operated under controlled conditions over a wide range of CO-concentrations in the H.sub.2 fuel stream.

Meltser, Mark Alexander (Pittsford, NY)

1999-01-01T23:59:59.000Z

220

Pattern recognition monitoring of PEM fuel cell  

DOE Patents (OSTI)

The CO-concentration in the H{sub 2} feed stream to a PEM fuel cell stack is monitored by measuring current and voltage behavior patterns from an auxiliary cell attached to the end of the stack. The auxiliary cell is connected to the same oxygen and hydrogen feed manifolds that supply the stack, and discharges through a constant load. Pattern recognition software compares the current and voltage patterns from the auxiliary cell to current and voltage signature determined from a reference cell similar to the auxiliary cell and operated under controlled conditions over a wide range of CO-concentrations in the H{sub 2} fuel stream. 4 figs.

Meltser, M.A.

1999-08-31T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Capacitively coupled RF voltage probe having optimized flux linkage  

DOE Patents (OSTI)

An RF sensor having a novel current sensing probe and a voltage sensing probe to measure voltage and current. The current sensor is disposed in a transmission line to link all of the flux generated by the flowing current in order to obtain an accurate measurement. The voltage sensor is a flat plate which operates as a capacitive plate to sense voltage on a center conductor of the transmission line, in which the measured voltage is obtained across a resistance leg of a R-C differentiator circuit formed by the characteristic impedance of a connecting transmission line and a capacitance of the plate, which is positioned proximal to the center conductor.

Moore, James A. (Powell, TN); Sparks, Dennis O. (Maryville, TN)

1999-02-02T23:59:59.000Z

222

Method of Controlling Corona Effects and Breakdown Voltage of Small Air Gaps Stressed by Impulse Voltages  

E-Print Network (OSTI)

This paper investigates the influence of a resistor on the dielectric behavior of an air gap. The resistor is connected in series with the air gap and the latter is stressed by impulse voltage. Air gap arrangements of different geometry with either the rod or the plate grounded are stressed with impulse voltages of both positive and negative polarity. The resistor is connected in series with the air gap in the return circuit connecting the gap with the impulse generator. The method followed involves the investigation of the graphs of the charging time concerning the air gaps capacitances, in connection to the value of the resistor, the geometry of the gap, the effect of grounding and the polarity effect. It is determined that the charging time of the air gap increases, as the value of the resistor increases. It is also determined that the peak voltage value of the fully charged air gap decreases as the value of the resistor increases. The results of the mathematical and simulation analysis are compared with the results of the oscillograms taken from experimental work. In addition and consequently to the above results it is concluded from the experimental work that the in series connection of the resistor in the circuit has significant influence on corona pulses (partial discharges) occurring in the gap and on the breakdown voltage of the gap. A new method of controlling the corona effects and consequently the breakdown voltage of small air gaps stressed by impulse voltage of short duration in connection to the ground effect and the polarity effect has arisen. Furthermore through mathematical analysis of the charging graphs obtained from simulation and experimental oscillograms there was a calculation of the values of the capacitance of the air gaps in relation to their geometry and the results were compared to the values calculated with mathematical analysis.

Athanasios Maglaras; Trifon Kousiouris; Frangiskos Topalis; Dimitrios Katsaros; Leandros A. Maglaras; Konstantina Giannakopoulou

2014-10-15T23:59:59.000Z

223

Transient recovery voltage considerations in the application of medium voltage circuit breakers  

SciTech Connect

Medium Voltage Circuit Breakers can fail to interrupt 3-phase fault currents when power systems have Transient Recovery Voltage (TRV) characteristics which exceed the rating of the circuit breaker. This paper examines the application of 13.8kV generation and load switchgear for an oil refinery in which circuit parameters as originally designed would have exceeded the 13.8kV circuit breakers TRV ratings had corrective measures not been taken. This paper illustrates this case and discusses the basis of TRV, how TRV is assessed, and alternative actions taken to bring circuits to within the 13.8 kV circuit breaker ratings.

Swindler, D.L.; Schwartz, P.; Hamer, P.S.; Lambert, S.R.

1995-12-31T23:59:59.000Z

224

Kirchhoff voltage law corrected for radiating circuits  

E-Print Network (OSTI)

When a circular loop composed by a RLC is put to oscillate, the oscillation will eventually vanish in an exponentially decaying current, even considering superconducting wires, due to the emission of electric and magnetic dipole radiation. In this work we propose a modification on the Kirchhoff voltage law by adding the radiative contributions to the energy loss as an effective resistance, whose value is relatively small when compared to typical resistance value, but fundamental to describe correctly real circuits. We have also analysed the change in the pattern of the radiation spectra emitted by the circuit as we vary both the effective and electrical resistance.

Lara, Vitor

2014-01-01T23:59:59.000Z

225

A High Voltage Direct Current Generator  

Science Journals Connector (OSTI)

When powdered materials are blown through metal tubes by means of compressed air considerable quantities of electricity are produced by contact electrification. It was found that 6×10-5 coulombs could be produced per gram of diatomaceous earth, a form of silica, blown through a short length of copper tube. A generator of extremely high voltage is proposed, and a small scale model of such a generator is described, by means of which currents of 8×10-5 amperes at 260 kilovolts were generated.

Richard E. Vollrath

1932-10-15T23:59:59.000Z

226

Dependence of Band Offset and Open-Circuit Voltage on the Interfacial Interaction between TiO2 and Carboxylated Polythiophenes  

E-Print Network (OSTI)

the open-circuit voltage. An attractive approach for making low-cost photovoltaic (PV) cells is to use bulk, 2005 The interface of planar TiO2/polymer photovoltaic cells was modified with two carboxylated to titania surfaces in photovoltaic cells. If the density of attachment groups is just enough to attach

McGehee, Michael

227

HIGH-VOLTAGE SPINEL AND POLYANION CATHODES  

Energy.gov (U.S. Department of Energy (DOE))

2012 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

228

High Voltage Electrolyte for Lithium Batteries  

Energy.gov (U.S. Department of Energy (DOE))

2012 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

229

Safe epoxy encapsulant for high voltage magnetics  

SciTech Connect

This paper describes the use of Formula 456, an aliphatic amine cured epoxy for impregnating coils and high voltage transformers. Sandia has evaluated a number of MDA-free epoxy encapsulants which relied on either anhydride or other aromatic amine curing agents. The use of aliphatic amine curing agents was more recently evaluated and has resulted in the definition of Formula 456 resin. Methylene dianiline (MDA) has been used for more than 20 years as the curing agent for various epoxy formulations throughout the Department of Energy and much of industry. Sandia National Laboratories began the process of replacing MDA with other formulations because of regulations imposed by OSHA on the use of MDA. OSHA has regulated MDA because it is a suspect carcinogen. Typically the elimination of OSHA-regulated materials provides a rare opportunity to qualify new formulations in a range of demanding applications. It was important to take full advantage of that opportunity, although the associated materials qualification effort was costly. Small high voltage transformers are one of those demanding applications. The successful implementation of the new formulation for high reliability transformers will be described. The test results that demonstrate the parts are qualified for use in DOE weapon systems will be presented.

Sanchez, R.O.; Archer, W.E.

1998-01-01T23:59:59.000Z

230

Accelerator System Development at High Voltage Engineering  

SciTech Connect

Throughout the years, HVE has continuously extended the capabilities of its accelerator systems to meet the rising demands from a diverse field of applications, among which are deep level ion implantation, micro-machining, neutron production for biomedical research, isotope production or accelerator mass spectrometry. Characteristic for HVE accelerators is the coaxial construction of the all solid state power supply around the acceleration tubes. With the use of solid state technology, the accelerators feature high stability and very low ripple. Terminal voltages range from 1 to 6 MV for HVE Singletrons and Tandetrons. The high-current versions of these accelerators can provide ion beams with powers of several kW. In the last years, several systems have been built with terminal voltages of 1.25 MV, 2 MV and 5 MV. Recently, the first system based on a 6 MV Tandetron has passed the factory tests. In this paper we describe the characteristics of the HVE accelerator systems and present as example recent systems.

Klein, M. G.; Gottdang, A.; Haitsma, R. G.; Mous, D. J. W. [High Voltage Engineering Europa B.V., P.O. Box 99, Amersfoort 3800 AB (Netherlands)

2009-03-10T23:59:59.000Z

231

Low voltage operation of plasma focus  

Science Journals Connector (OSTI)

Plasma foci of compact sizes and operating with low energies (from tens of joules to few hundred joules) have found application in recent years and have attracted plasma-physics scientists and engineers for research in this direction. We are presenting a low energy and miniature plasma focus which operates from a capacitor bank of 8.4 ? ? F capacity charged at 4.2–4.3 kV and delivering approximately 52 kA peak current at approximately 60 nH calculated circuit inductance. The total circuit inductance includes the plasma focusinductance. The reported plasma focus operates at the lowest voltage among all reported plasma foci so far. Moreover the cost of capacitor bank used for plasma focus is nearly 20 U.S. dollars making it very cheap. At low voltage operation of plasma focus the initial breakdown mechanism becomes important for operation of plasma focus. The quartz glass tube is used as insulator and breakdown initiation is done on its surface. The total energy of the plasma focus is approximately 75 J. The plasma focus system is made compact and the switching of capacitor bank energy is done by manual operating switch. The focus is operated with hydrogen and deuterium filled at 1–2 mbar.

Rohit Shukla; S. K. Sharma; P. Banerjee; R. Das; P. Deb; T. Prabahar; B. K. Das; B. Adhikary; A. Shyam

2010-01-01T23:59:59.000Z

232

An advanced fuel cell simulator  

E-Print Network (OSTI)

of Fuel Cells ...................... 4 D. Fuel Cell Power Plant ..................... 4 E. Challenges in Fuel Cell Development ............ 5 F. Previous Work ......................... 6 G. Solar Array Simulators .................... 8 H. Battery... ............................. 54 28 Under-voltage Fault ........................... 55 1 CHAPTER I INTRODUCTION The depleting fossil fuel resources and increasing pollution are leading to the research and development of alternate energy generation techniques like fuel cells...

Acharya, Prabha Ramchandra

2005-11-01T23:59:59.000Z

233

NOMINATIONS INVITED The Executive Director of the Karl W. Ber Solar Energy Medal of Merit Trust, Prof. Michael T. Klein  

E-Print Network (OSTI)

NOMINATIONS INVITED · The Executive Director of the Karl W. Böer Solar Energy Medal of Merit Trust will be awarded to an individual who has made significant pioneering contributions in solar energy, wind energy to the fields of solar energy, wind energy, or other forms of renewable energy in other ways. PANEL OF JUDGES

Firestone, Jeremy

234

PUBLIC ADVISER DUTY STATEMENT The California Energy Commission shall nominate and the Governor shall appoint for a term of three  

E-Print Network (OSTI)

PUBLIC ADVISER DUTY STATEMENT The California Energy Commission shall nominate and the Governor shall appoint for a term of three years a public adviser to the Commission who shall be an attorney and the public at large is secured in the planning, site and facility certification, energy conservation

235

The Long-Run Relationship between Money, Nominal GDP, and the Price Level in Venezuela: 1950 to 1996  

E-Print Network (OSTI)

that structural breaks may be important. Since the economy depends heavily on oil revenue, oil price shocks haveThe Long-Run Relationship between Money, Nominal GDP, and the Price Level in Venezuela: 1950 and the price level in the Venezuelan economy. We apply time-series econometric techniques to annual data

Ahmad, Sajjad

236

Chemical detection and laser wavelength stabilization employing spectroscopic absorption via laser compliance voltage sensing  

DOE Patents (OSTI)

Systems and methods are disclosed that provide a direct indication of the presence and concentration of an analyte within the external cavity of a laser device that employ the compliance voltage across the laser device. The systems can provide stabilization of the laser wavelength. The systems and methods can obviate the need for an external optical detector, an external gas cell, or other sensing region and reduce the complexity and size of the sensing configuration.

Taubman, Matthew S; Phillips, Mark C

2014-03-18T23:59:59.000Z

237

Design and applications of a flicker voltage generator  

SciTech Connect

In this paper, a 200W flicker voltage generator is made by using microcomputers and linear amplification circuits. The modulation amplitudes and frequencies based on the UIE {Delta}V{sub 10} evaluation can be arbitrarily assigned by software with high accuracy. The flicker voltage signals measured at the customer side also can be re-generated. Some applications, such as evaluating the effects of flicker voltage on incandescent and compact fluorescent lamps (CFLs), are also made. From experimental tests by use of the flicker voltage generator, the properties of some compact fluorescent lamps and incandescent lamps are compared. Those properties describe the relation between input voltage variation and output flux of lamps, such that there is direct description of influences of flicker voltages on lamps.

Chang, W.N.; Wu, C.J. [National Taiwan Inst. of Tech., Peitow-Taipei (Taiwan, Province of China). Dept. of Electrical Engineering

1995-12-31T23:59:59.000Z

238

Scenarios constructed for nominal flow in the presence of a repository at Yucca Mountain and vicinity  

SciTech Connect

Scenario development for the system performance assessment of the Yucca Mountain Site Characterization Project defines a scenario as a well-posed problem connecting an initiating event with radionuclide release to the accessible environment by a logical and physically possible combination or sequence of features, events, and processes. Drawing on the advice and assistance of the Project`s principal investigators (PIs), a collection of release scenarios initiated by the nominal ground-water flow occurring in the vicinity of the potential Yucca Mountain high-level-waste repository is developed and described in pictorial form. This collection of scenarios is intended to provide a framework to assist PIs in recognizing essential field and calculational analyses, to assist performance assessment in providing guidance to site characterization, and to continue the effort to exhaustively identify all features, events, and processes important to releases. It represents a step in the iterative process of identifying what details of the potential site are important for safe disposal. 67 refs.

Barr, G.E.; Hunter, R.L.; Dunn, E. [Sandia National Labs., Albuquerque, NM (United States); Flint, A. [Geological Survey, Mercury, NV (United States)

1995-03-01T23:59:59.000Z

239

Voltage stabilization system in traction substation of urban electric transport  

Science Journals Connector (OSTI)

The direct current-voltage stabilization system using a high-frequency link in traction substations of urban electric transport based on applying...

S. V. Shapiro; S. F. Muftiev

2011-02-01T23:59:59.000Z

240

High Temperature, High Voltage Fully Integrated Gate Driver Circuit  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

driver circuit, 5-V on- chip voltage regulator, short-circuit protection, undervoltage lockout, bootstrap capacitor, dead time controller and temperature sensor * 0.8-micron,...

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Triple voltage dc-to-dc converter and method  

DOE Patents (OSTI)

A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

Su, Gui-Jia (Knoxville, TN)

2008-08-05T23:59:59.000Z

242

fault diagnosis of a high voltage transmission line using waveform ...  

E-Print Network (OSTI)

Oct 4, 2013 ... FAULT DIAGNOSIS OF A HIGH VOLTAGE TRANSMISSION LINE USING ... Fault types such as single line to ground, line to line, double line to ...

Ripunjoy Phukan

2013-10-04T23:59:59.000Z

243

Low voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips  

Science Journals Connector (OSTI)

Abstract This paper proposes a competent and effective scheme to enhance the ride-through capability of DFIG-based wind turbines under unbalanced voltage dip conditions. The proposed method is realized through joint use of the rotor-side converter control and a three-phase stator damping resistor (SDR) placed in series with the stator windings. By means of an asymmetrical SDR idea, during the unbalanced voltage dip the SDR resistors are activated only in phase(s) experiencing low voltage. Then, the rotor current is controlled such that no unbalance voltage appears on the stator voltage. The proposed ride-through approach limits the peak values of the rotor inrush current, electromagnetic torque and DFIG transient response at the times of occurrence and clearing the fault. It also suppresses fluctuation of the electromagnetic torque and DFIG transient response appeared during unbalanced voltage dips due to negative sequence component.

Mohsen Rahimi; Mostafa Parniani

2014-01-01T23:59:59.000Z

244

Vehicle Technologies Office Merit Review 2014: The Voltage Fade Project, A New Paradigm for Applied Battery Research  

Energy.gov (U.S. Department of Energy (DOE))

Presentation given by the Department of Energy's Energy Storage area at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about a new approach to the challenge of voltage fade in batteries for plug-in electric vehicles.

245

Mathematical modelling of the catalyst layer of a polymer electrolyte fuel cell  

Science Journals Connector (OSTI)

......polymer electrolyte fuel cell A. A. Shah...polymer electrolyte fuel cell. The model explicitly...unwanted reactions (degradation), such as carbon...certain ranges of cell voltage). (5...performance of the fuel cell. We point......

A. A. Shah; Gwang-Soo Kim; K. Promislow

2007-06-01T23:59:59.000Z

246

Power Management for Alleviation of the Impact on PEM Fuel Cell due to Load Fluctuation  

Science Journals Connector (OSTI)

Transient impact on fuel cell system due to stack current fluctuation sometimes causes severe degradation of some performances such as voltage variation, oxygen starvation, anode/cathode pressure disturbance, membrane dryout and voltage reversal. As ...

Guidong Liu; Wensheng Yu; Zhishou Tu

2006-10-01T23:59:59.000Z

247

Simplified VO M&V Protocol Simplified Voltage Optimization (VO)  

E-Print Network (OSTI)

Simplified VO M&V Protocol 1 Simplified Voltage Optimization (VO) Measurement and Verification Protocol 1.0 Introduction 1.1 Purpose The Simplified Voltage Optimization (VO) Measurement and Verification requirements, and measurement and verification formulations are included as part of this Protocol. 1

248

Task Scheduling and Voltage Selection for Energy Minimization  

E-Print Network (OSTI)

system con gurations. 1. INTRODUCTION Energy consumption has become a primary concern in today's ICTask Scheduling and Voltage Selection for Energy Minimization Yumin Zhang Synopsys, Inc. 700 East-phase framework that inte- grates task assignment, ordering and voltage selection VS together to minimize energy

Hu, Xiaobo Sharon

249

IMPACT OF DYNAMIC VOLTAGE SCALING (DVS) ON CIRCUIT OPTIMIZATION  

E-Print Network (OSTI)

and dynamic power, respectively. Both gate sizing and Dual-VT are design-time techniques, which are applied to the circuit at a fixed voltage. On the other hand, DVS is a run-time technique and implies that the circuit will be operating at a different voltage...

Esquit Hernandez, Carlos A.

2010-01-16T23:59:59.000Z

250

REFINED RFP LOOP VOLTAGE CALCULATION J.C. Sprott  

E-Print Network (OSTI)

is the stored magnetic energy, Up is the plasma energy, and 'E is the global energy confinement time, which-of-merit for RFP devices is the loop voltage. Low loop voltage implies high plasma temperature and long energy is smallest if the loop is as close to the outside of the shell and as far from the primary windings

Sprott, Julien Clinton

251

LOW VOLTAGE ANALOG CIRCUITS USING STANDARD CMOS TECHNOLOGY  

E-Print Network (OSTI)

LOW VOLTAGE ANALOG CIRCUITS USING STANDARD CMOS TECHNOLOGY Phillip E. Allen, Benjamin J. Blalock, and Gabriel A. Rincon School of Electrical and Computer Engineering Georgia Institute of Technology Atlanta supply voltages in CMOS integrated circuits. As the channel lengths of CMOS technology decrease

Rincon-Mora, Gabriel A.

252

Measurement of high voltage using Rutherford backscattering spectrometry  

E-Print Network (OSTI)

A novel variation of Rutherford Backscattering Spectrometry (RBS) has been utilized to measure a high voltage collected on an aluminum target by Direct Energy Conversion. The maximum high voltage on the target was measured to be 97.5 kV +/- 2 kV...

Abrego, Celestino Pete

2007-04-25T23:59:59.000Z

253

Nonlinear voltages in multiple-lead coherent conductors  

Science Journals Connector (OSTI)

We use the generalized S-matrix approach to study multiple-lead coherent conductors in the case of finite applied voltages. In this framework we discuss the transverse voltage arising in a four-lead conductor with two symmetric biased leads.

Gordey B. Lesovik and Carlo Presilla

1993-01-15T23:59:59.000Z

254

The Cavendish high-voltage laboratory 1935–39  

Science Journals Connector (OSTI)

...the period covered. Nuclear Transmutation|Cavendish...development of high-voltage nuclear transmutation equipment...experimental work in nuclear physics though he continued...a new high-voltage accelerator therefore fell mainly...doubler circuit with six vacuum rectifiers forming a...

1999-01-01T23:59:59.000Z

255

Bonfire-safe low-voltage detonator  

DOE Patents (OSTI)

A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half.

Lieberman, Morton L. (Albuquerque, NM)

1990-01-01T23:59:59.000Z

256

Definition: Automated Voltage And Var Control | Open Energy Information  

Open Energy Info (EERE)

Voltage And Var Control Voltage And Var Control Jump to: navigation, search Dictionary.png Automated Voltage And Var Control Automated voltage and VAR control requires coordinated operation of reactive power resources such as capacitor banks, voltage regulators, transformer load-tap changers, and distributed generation (DG) with sensors, controls, and communications systems. These devices could operate autonomously in response to local events or in response to signals from a central control system.[1] View on Wikipedia Wikipedia Definition Also Known As Volt-VAR Control (VVC) Related Terms smart grid, Reactive Power References ↑ SmartGrid.gov 'Description of Functions' An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from

257

Living and Working Safely Around High-Voltage Power Lines.  

SciTech Connect

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

United States. Bonneville Power Administration.

2001-06-01T23:59:59.000Z

258

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1996-01-01T23:59:59.000Z

259

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

Shimer, D.W.; Lange, A.C.

1996-10-15T23:59:59.000Z

260

An amorphous alloy core medium frequency magnetic-link for medium voltage photovoltaic inverters  

Science Journals Connector (OSTI)

The advanced magnetic materials with high saturation flux density and low specific core loss have led to the development of an efficient compact and lightweight multiple-input multiple-output medium frequency magnetic-link. It offers a new route to eliminate some critical limitations of recently proposed medium voltage photovoltaic inverters. In this paper a medium frequency magnetic-link is developed with Metglas amorphous alloy 2605S3A. The common magnetic-link generates isolated and balanced multiple DC supplies for all of the H-bridge inverter cells of the medium voltage inverter. The design and implementation of the prototype test platform and the experimental test results are analyzed and discussed. The medium frequency non-sinusoidal excitation electromagnetic characteristics of alloy 2605S3A are also compared with that of alloy 2605SA1. It is expected that the proposed new technology will have great potential for future renewable power generation systems and smart grid applications.

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

Shimer, D.W.; Lange, A.C.

1995-05-23T23:59:59.000Z

262

High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1995-01-01T23:59:59.000Z

263

Membrane Purification Cell for Aluminum Recycling  

SciTech Connect

Recycling mixed aluminum scrap usually requires adding primary aluminum to the scrap stream as a diluent to reduce the concentration of non-aluminum constituents used in aluminum alloys. Since primary aluminum production requires approximately 10 times more energy than melting scrap, the bulk of the energy and carbon dioxide emissions for recycling are associated with using primary aluminum as a diluent. Eliminating the need for using primary aluminum as a diluent would dramatically reduce energy requirements, decrease carbon dioxide emissions, and increase scrap utilization in recycling. Electrorefining can be used to extract pure aluminum from mixed scrap. Some example applications include producing primary grade aluminum from specific scrap streams such as consumer packaging and mixed alloy saw chips, and recycling multi-alloy products such as brazing sheet. Electrorefining can also be used to extract valuable alloying elements such as Li from Al-Li mixed scrap. This project was aimed at developing an electrorefining process for purifying aluminum to reduce energy consumption and emissions by 75% compared to conventional technology. An electrolytic molten aluminum purification process, utilizing a horizontal membrane cell anode, was designed, constructed, operated and validated. The electrorefining technology could also be used to produce ultra-high purity aluminum for advanced materials applications. The technical objectives for this project were to: - Validate the membrane cell concept with a lab-scale electrorefining cell; - Determine if previously identified voltage increase issue for chloride electrolytes holds for a fluoride-based electrolyte system; - Assess the probability that voltage change issues can be solved; and - Conduct a market and economic analysis to assess commercial feasibility. The process was tested using three different binary alloy compositions (Al-2.0 wt.% Cu, Al-4.7 wt.% Si, Al-0.6 wt.% Fe) and a brazing sheet scrap composition (Al-2.8 wt.% Si-0.7 wt.% Fe-0.8 wt.% Mn),. Purification factors (defined as the initial impurity concentration divided by the final impurity concentration) of greater than 20 were achieved for silicon, iron, copper, and manganese. Cell performance was measured using its current and voltage characteristics and composition analysis of the anode, cathode, and electrolytes. The various cells were autopsied as part of the study. Three electrolyte systems tested were: LiCl-10 wt. % AlCl3, LiCl-10 wt. % AlCl3-5 wt.% AlF3 and LiF-10 wt.% AlF3. An extended four-day run with the LiCl-10 wt.% AlCl3-5 wt.% AlF3 electrolyte system was stable for the entire duration of the experiment, running at energy requirements about one third of the Hoopes and the conventional Hall-Heroult process. Three different anode membranes were investigated with respect to their purification performance and survivability: a woven graphite cloth with 0.05 cm nominal thickness & > 90 % porosity, a drilled rigid membrane with nominal porosity of 33%, and another drilled rigid graphite membrane with increased thickness. The latter rigid drilled graphite was selected as the most promising membrane design. The economic viability of the membrane cell to purify scrap is sensitive to primary & scrap aluminum prices, and the cost of electricity. In particular, it is sensitive to the differential between scrap and primary aluminum price which is highly variable and dependent on the scrap source. In order to be economically viable, any scrap post-processing technology in the U.S. market must have a total operating cost well below the scrap price differential of $0.20-$0.40 per lb to the London Metal Exchange (LME), a margin of 65%-85% of the LME price. The cost to operate the membrane cell is estimated to be < $0.24/lb of purified aluminum. The energy cost is estimated to be $0.05/lb of purified aluminum with the remaining costs being repair and maintenance, electrolyte, labor, taxes and depreciation. The bench-scale work on membrane purification cell process has demonstrated technological advantages and subs

David DeYoung; James Wiswall; Cong Wang

2011-11-29T23:59:59.000Z

264

Electro-optic voltage sensor with Multiple Beam Splitting  

DOE Patents (OSTI)

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID)

2000-01-01T23:59:59.000Z

265

Electro-optic voltage sensor with beam splitting  

DOE Patents (OSTI)

The invention is a miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware typically found in the prior art. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

266

A Process and Supply Variation Tolerant Nano-CMOS Low Voltage, High Speed, A/D Converter for System-on-Chip  

E-Print Network (OSTI)

variations of 10.5% and 5.7% in the INL and DNL respectively, with nominal INL = 0.344LSB and nominal DNL = 0

Mohanty, Saraju P.

267

Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis  

E-Print Network (OSTI)

Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis Claudio A. Ca|Thispaper describesseveralapplica- tions of optimization for voltage stability analysis VSA of power systems. Voltage stability prob

Cañizares, Claudio A.

268

Laser beam apparatus and method for analyzing solar cells  

DOE Patents (OSTI)

A laser beam apparatus and method for analyzing, inter alia, the current versus voltage curve at the point of illumination on a solar cell and the open circuit voltage of a solar cell. The apparatus incorporates a lock-in amplifier, and a laser beam light chopper which permits the measurement of the AC current of the solar cell at an applied DC voltage at the position on the solar cell where the cell is illuminated and a feedback scheme which permits the direct scanning measurements of the open circuit voltage. The accuracy of the measurement is a function of the intensity and wavelength of the laser light with respect to the intensity and wavelength distribution of sunlight and the percentage the dark current is at the open circuit voltage to the short circuit current of the solar cell.

Staebler, David L. (Lawrenceville, NJ)

1980-01-01T23:59:59.000Z

269

Fabrication and Characterization of CIS/CdS and Cu2S/CdS Devices for Applications in Nano Structured Solar Cells.  

E-Print Network (OSTI)

??Nano structured solar cells provide an opportunity for increased open circuit voltages and and short circuit currents in solar cells due to quantum confinement of… (more)

Jayaraman, Visweswaran

2005-01-01T23:59:59.000Z

270

Optically triggered high voltage switch network and method for switching a high voltage  

DOE Patents (OSTI)

An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

1993-01-19T23:59:59.000Z

271

High-voltage supply for backward-wave tube  

SciTech Connect

A high-current high-voltage supply for a backward-wave tube is described that uses a generalppurpose semiconductor converter with pulse-width modulation and two-stage regulation. The load current is up to 250 mA for load voltages of from 0.5 to 4.5 kV. The voltage staiblity is less than or equal to 5 x 10/sup -6/. the root-mean-square output ripple is less than or equal to 2 x 10/sup -6// The supply is equipped with high-speed (5 usec) load-breakdown protection.

Bryvkhanov, A.N.; Kosarev, P.M.; Latushkin, S.T.; Yudin, L.I.

1986-04-01T23:59:59.000Z

272

Proton Exchange Membrane Fuel Cell degradation prediction based on Adaptive Neuro Fuzzy Inference Systems  

E-Print Network (OSTI)

Proton Exchange Membrane Fuel Cell degradation prediction based on Adaptive Neuro Fuzzy Inference online XX XX XXXX Keywords: Proton Exchange Membrane fuel cell degradation, Prognostic and Health nominal operating condition of a PEM fuel cell stack. It proposes a methodology based on Adaptive Neuro

Paris-Sud XI, Université de

273

Research to Prevent the Anti-charging Incident of the Voltage Transformer in the Substation  

Science Journals Connector (OSTI)

The voltage transformer of the power system is a device which converts the high voltage of the primary side into the low voltage required by secondary device, and the primary side connects to the primary syste...

Hui-Ying Chen; Zhi-Peng Wang; Mu-Qin Tian

2011-01-01T23:59:59.000Z

274

High-voltage air-core pulse transformers  

SciTech Connect

General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

Rohwein, G. J.

1981-01-01T23:59:59.000Z

275

Eliminate Excessive In-Plant Distribution System Voltage Drops...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

connections-can account for less than 1% to more than 4% of total plant electrical energy consumption. This two-page tip sheet recommends conducting a voltage drop survey and...

276

Optical crystal based devices for current and voltage measurement  

SciTech Connect

A prerequisite for safe, stable operation of an electric power system is accurate, reliable measurement of the system parameters, in particular, current and voltage. Traditionally this has been achieved on High Voltage (HV) systems by expensive, bulky iron-cored current transformers (CTs) and capacitor voltage transformers (VTs). Both these devices are increasingly coming under review in modern power systems due to their cost, safety implications for personnel and surrounding plant if failure occurs, installation time and indeed substation land requirements. This paper describes novel designs for magneto-optic and electro-optic crystal sensors providing potentially separate and combined current and voltage measurement. The results of testing programs are presented and details of the work associated with field trials given.

Cruden, A.; Richardson, Z.J.; McDonald, J.R.; Andonovic, I. [Univ. of Strathclyde (United Kingdom)] [Univ. of Strathclyde (United Kingdom)

1995-07-01T23:59:59.000Z

277

Long term voltage stability analysis for small disturbances  

E-Print Network (OSTI)

This dissertation attempts to establish an analytical and comprehensive framework to deal with two critical challenges associated with voltage stability analysis: 1. To study the new competitive environment appropriately and give more incentive...

Men, Kun

2009-05-15T23:59:59.000Z

278

Voltage asymmetry at the buses of a combined substation  

Science Journals Connector (OSTI)

The voltage asymmetry at the buses of a combined (ac/dc) substation is calculated by phase method, using Mathcad ... , power may be supplied to a combined substation along a common line from a limited-...

A. G. Pakulin; V. A. Zagorskii; V. F. Put’ko

2013-07-01T23:59:59.000Z

279

Operation of buck regulator with ultra-low input voltage  

E-Print Network (OSTI)

Based on the LTC3621 and LTC3624, the designed buck regulator proposed in this thesis aims to lower the allowed input voltage and increase efficiency compared to the original part without making significant changes to ...

Harris, Cory Angelo

2014-01-01T23:59:59.000Z

280

Voltage Regulator Chip: Power Supplies on a Chip  

SciTech Connect

ADEPT Project: CPES at Virginia Tech is finding ways to save real estate on a computer's motherboard that could be used for other critical functions. Every computer processor today contains a voltage regulator that automatically maintains a constant level of electricity entering the device. These regulators contain bulky components and take up about 30% of a computer's motherboard. CPES at Virginia Tech is developing a voltage regulator that uses semiconductors made of gallium nitride on silicon (GaN-on-Si) and high-frequency soft magnetic material. These materials are integrated on a small, 3D chip that can handle the same amount of power as traditional voltage regulators at 1/10 the size and with improved efficiency. The small size also frees up to 90% of the motherboard space occupied by current voltage regulators.

None

2010-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Reactive Support and Voltage Control Service: Key Issues and Challenges  

E-Print Network (OSTI)

Reactive Support and Voltage Control Service: Key Issues and Challenges George Gross^, Paolo of Illinois at Urbana-Champaign, Urbana, IL 61801, USA, e-mail gross@uiuc.edu ° Dipartimento di Ingegneria

Gross, George

282

Automotive high-voltage electrical system with integrated safeguard  

Science Journals Connector (OSTI)

For several years the use of higher system voltages has been a topic in the automotive industry. Whether for hybrid or conventional vehicles, safeguards are required which protect both the vehicle...

Thomas Flottmann

2007-03-01T23:59:59.000Z

283

High Voltage Electrolytes for Li-ion Batteries | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

in Support of 5 V Li-ion Chemistries Vehicle Technologies Office Merit Review 2014: Fluorinated Electrolyte for 5-V Li-Ion Chemistry High Voltage Electrolyte for Lithium Batteries...

284

High voltage dry-type air-core shunt reactors  

Science Journals Connector (OSTI)

Dry-type air-core shunt reactors are now being ... systems to limit overvoltages. Recently, high voltage dry-type air-core shunt reactors have been designed, ... transient overvoltages and electrical and magnetic...

Klaus Papp; Michael R. Sharp…

2014-11-01T23:59:59.000Z

285

High-speed low-voltage ultraviolet light source  

Science Journals Connector (OSTI)

A novel quasi-spark gap has been designed and constructed with high-speed and low-spark voltage characteristics. Ultraviolet light generating sparks can be operated at a rate of up to...

Huang, L; Hsu, S C; Kwok, H S

1984-01-01T23:59:59.000Z

286

LM111/LM211/LM311 Voltage Comparator  

E-Print Network (OSTI)

LM111/LM211/LM311 Voltage Comparator 1.0 General Description The LM111, LM211 and LM311 are voltage comparators that have input currents nearly a thousand times lower than devices like the LM106 or LM710A. Both the inputs and the outputs of the LM111, LM211 or the LM311 can be isolated from system ground

Lanterman, Aaron

287

Sinusoidal voltage controlled oscillators using operational transconductance amplifiers  

E-Print Network (OSTI)

SINUSOIDAI. VOLTAGE CONTROLLED OSCILLATORS I. SING OPERATIONAL TRANSCONDUCTANCE AMPLIFIERS A Thesis JAVIFB . IOAQUIN HOYI. K I'ASSANO Suhndtted to the Graduate College ol' 'I'exes A8cM University in partial fulfillment of the requirement... for the degree of MASTER OF SCIENCE May 1985 Major Subject: Electrical Engineering SINUSOIDAL VOLTAGE CONTROLLED OSCILLATORS USING OPERATIONAI, TRANSCONDUCTANCE AMPLIFIERS A Thesis by JAVIER JOAQUIN HOYLE PASSANO Approved as to style and content by: o...

Hoyle Passano, Javier Joaquin

1985-01-01T23:59:59.000Z

288

Image-line voltage controlled oscillators and grating antennas  

E-Print Network (OSTI)

IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Submitted to the Office of Graduate Studies of Texas ABM University in partial fulfillment of the requirements for the degree of MASTER... OF SCIENCE May 1991 Major Subject: Electrical Engineering IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Approved as to style and content by: Kai Chang (Chair of Committee) Robert D. Nevels...

Kirk, Alexander MacDonald

1991-01-01T23:59:59.000Z

289

Design issues for high voltage converters for ion engines  

SciTech Connect

A design strategy is presented for a power converter for a high voltage ion engine for a spacecraft application. Various design issues such as appropriate topologies and control methods are considered. In this particular instance it was determined that a full bridge converter with phase shift gating and voltage mode control provided an efficient system with a minimum of electromagnetic interference. This system can be implemented in a straightforward manner, and it is relatively easy to protect from faults at the output.

King, R.J.; Stuart, T.A. [Univ. of Toledo, OH (United States)

1995-12-31T23:59:59.000Z

290

High voltage electrical amplifier having a short rise time  

DOE Patents (OSTI)

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

1991-01-01T23:59:59.000Z

291

Centralized wind power plant voltage control with optimal power flow algorithm.  

E-Print Network (OSTI)

??This thesis presents a method of controlling the reactive power injected into a medium-voltage collection system by multiple wind turbine generators such that the voltage… (more)

Kline, Jared Andrew

2011-01-01T23:59:59.000Z

292

Low Voltage Electrostatic Actuation and Displacement Measurement through Resonant Drive Circuit.  

E-Print Network (OSTI)

??An electrostatic actuator driven by conventional voltage control and charge control requires high actuation voltage and suffers from the pull-in phenomenon that limits its operation… (more)

Park, Sangtak

2011-01-01T23:59:59.000Z

293

Manganese carbonate additive for manganese dioxide-containing nonaqueous cells  

SciTech Connect

A nonaqueous cell employing a manganese dioxide-containing solid cathode having a minor amount of manganese carbonate to improve the pulse voltage capability of the cell at low temperatures such as -10/sup 0/ C.

Langan, R.A.

1984-10-23T23:59:59.000Z

294

Experimental analysis of I–V characteristics of solar cells  

Science Journals Connector (OSTI)

This paper describes a simple experiment that can be performed by undergraduate students to derive the values of solar cell parameters from the plot of the output load current versus the voltage at the terminals of the cell.

P. Mialhe; J. Charette

1983-01-01T23:59:59.000Z

295

The genera)on and survival of nerve cells  

E-Print Network (OSTI)

the helix-loop-helix transcrip)on factor path Ectodermal cells Proneural region and notch at similar levels Feedback loop Notch signaling Neuronal fate #12 voltage activated calcium channels Schwann cell #12;Astrocytes Protoplasmic astrocytes: gray matter

Alford, Simon

296

General equivalent circuit of batteries and fuel cells  

Science Journals Connector (OSTI)

A general electrical circuit is described whose properties are analogous to those of fuel cells and batteries. It is shown how this equivalent circuit ... in the electrolyte on the output voltage of fuel cells an...

R. A. Huggins

1999-01-01T23:59:59.000Z

297

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

Shimer, D.W.; Lange, A.C.

1997-03-11T23:59:59.000Z

298

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1997-01-01T23:59:59.000Z

299

Simultaneous use of MRM (maximum rectangle method) and optimization methods in determining nominal capacity of gas engines in CCHP (combined cooling, heating and power) systems  

Science Journals Connector (OSTI)

Abstract Energy, economic, and environmental analyses of combined cooling, heating and power (CCHP) systems were performed here to select the nominal capacities of gas engines by combination of optimization algorithm and maximum rectangle method (MRM). The analysis was performed for both priority of providing electricity (PE) and priority of providing heat (PH) operation strategies. Four scenarios (SELL-PE, SELL-PH, No SELL-PE, No SELL-PH) were followed to specify design parameters such as the number and nominal power of prime movers, heating capacities of both backup boiler and energy storage tank, and the cooling capacities of electrical and absorption chillers. By defining an objective function called the Relative Annual Benefit (RAB), Genetic Algorithm optimization method was used for finding the optimal values of design parameters. The optimization results indicated that two gas engines (with nominal powers of 3780 and 3930 kW) in SELL-PE scenario, two gas engines (with nominal powers of 5290 and 5300 kW) in SELL-PH scenario, one gas engine (with nominal power of 2440 kW) in No SELL-PE scenario provided the maximum value of the objective function. Furthermore in No SELL-PE scenario (which had the lowest RAB value in comparison with that for the above mentioned scenarios), thermal energy storage was not required. Due to very low value of RAB, any gas engine in No SELL-PH scenario was not recommended.

Sepehr Sanaye; Navid Khakpaay

2014-01-01T23:59:59.000Z

300

Minimization of voltage deviation and power losses in power networks using Pareto optimization methods  

Science Journals Connector (OSTI)

Voltage regulation is an important task in electrical engineering for controlling node voltages in a power network. A widely used solution for the problem of voltage regulation is based on adjusting the taps in under load tap changers (ULTCs) power transformers ... Keywords: Multi-objective optimization, Power distribution network, Power losses, Under load tap changers, Voltage regulation

Francisco G. Montoya; Raúl Baños; Consolación Gil; Antonio Espín; Alfredo Alcayde; Julio Gómez

2010-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Requirements for a Standard Test to Rate the Durability of PV Modules at System Voltage (Presentation)  

SciTech Connect

Degradation modes in photovoltaic modules under system bias voltage stress are described and classified.

Hacke, P.; Terwilliger, K.; Glick, S.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-02-01T23:59:59.000Z

302

Summaries of Addresses of Presidents of Sections: High-Voltage Insulation  

Science Journals Connector (OSTI)

... subject of his presidential address to Section A (Mathematics and Physics) *'High-voltage Insulation".

1963-08-31T23:59:59.000Z

303

Elevated voltage level I.sub.DDQ failure testing of integrated circuits  

DOE Patents (OSTI)

Burn in testing of static CMOS IC's is eliminated by I.sub.DDQ testing at elevated voltage levels. These voltage levels are at least 25% higher than the normal operating voltage for the IC but are below voltage levels that would cause damage to the chip.

Righter, Alan W. (Albuquerque, NM)

1996-01-01T23:59:59.000Z

304

Elevated voltage level I{sub DDQ} failure testing of integrated circuits  

DOE Patents (OSTI)

Burn in testing of static CMOS IC`s is eliminated by I{sub DDQ} testing at elevated voltage levels. These voltage levels are at least 25% higher than the normal operating voltage for the IC but are below voltage levels that would cause damage to the chip. 4 figs.

Righter, A.W.

1996-05-21T23:59:59.000Z

305

Graz University of Technology Institute of High Voltage Engineering and System Performance  

E-Print Network (OSTI)

.hspt@tugraz.at u www.hspt.tugraz.at Institute of High Voltage Engineering and System Performance Test Laboratory systems Test of insulators, fittings and accessories Testing of high voltage equipment Impulse voltage and current tests On-site-test of medium voltage cables Electrical methods in environmental technology

306

Investigating the efficiency of Silicon Solar cells at  

E-Print Network (OSTI)

Investigating the efficiency of Silicon Solar cells at different temperatures and wavelengths to study the characteristics of silicon photovoltaic cells (solar cells). We vary the wavelength of light as well as the temperature of the solar cell to investigate how the open voltage across the cell varies

Attari, Shahzeen Z.

307

Experiment Hazard Class 13.0 - High Voltage  

NLE Websites -- All DOE Office Websites (Extended Search)

3.0 - High Voltage 3.0 - High Voltage Applicability This hazard classification applies to all experiments involving the use of High Voltage Equipment. Other hazard classifications and their associated hazard controls may also apply to experiments in this hazard class. The inspection of electric equipment is covered under the APS Policy For User Electric Equipment Inspections. NOTE: Unless required Argonne training has been completed, users are not authorized to perform electrical work. Experiment Category All Hazard Class 13 experiments are categorized as medium risk experiments. Experiment Hazard Control Verification Statements Engineered Controls - Determined by review and results of a DEEI inspection of the equipment. Procedural Controls - Determined by review and results of a DEEI

308

High voltage stability performance of a gamma ray detection device  

SciTech Connect

An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

Abdullah, Nor Arymaswati; Lombigit, Lojius; Rahman, Nur Aira Abd [Technical Support Division, Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)

2014-02-12T23:59:59.000Z

309

Voltage controlled stand-alone microhydro induction generator system  

Science Journals Connector (OSTI)

The paper discusses simulated control cases of the wound rotor self-excited induction generator WRSEIG. The generator external controller is designed to regulate the output voltage and frequency for constant or variable speed operation of the prime mover and has the inherent capability of protecting the load from short circuit, which permits voltage collapse under heavy loads. WRSEIG is self-excited using one set of excitation capacitance connected across the generator stator side. At the rotor side, a PWM controlled resistor is connected to the rotor windings through the rotating slips and act as a slip power controller. The controller can be configured to regulate the voltage as the speed or the load changes. The presented system has the capability to generate good quality AC power source with minimum controlling elements and can operate under constant or adjustable prime mover speed that suits many microhydro electricity-generating plants.

K.A. Nigim

2005-01-01T23:59:59.000Z

310

Voltage Impacts of Utility-Scale Distributed Wind  

SciTech Connect

Although most utility-scale wind turbines in the United States are added at the transmission level in large wind power plants, distributed wind power offers an alternative that could increase the overall wind power penetration without the need for additional transmission. This report examines the distribution feeder-level voltage issues that can arise when adding utility-scale wind turbines to the distribution system. Four of the Pacific Northwest National Laboratory taxonomy feeders were examined in detail to study the voltage issues associated with adding wind turbines at different distances from the sub-station. General rules relating feeder resistance up to the point of turbine interconnection to the expected maximum voltage change levels were developed. Additional analysis examined line and transformer overvoltage conditions.

Allen, A.

2014-09-01T23:59:59.000Z

311

Self-Excited ac High Voltage Generation Using Water Droplets  

Science Journals Connector (OSTI)

By letting water drops fall through rings into cans high voltage can be spontaneously generated with no external electrical excitation. Previous work concerning this type of electric influence machine for dc and three-phase ac high voltage generation is extended to include multiphase multifrequency operation by considering N streams and N cans. A distributed equivalent circuit representation is used to calculate the natural frequencies of the system where it is found that many overstable modes are present. Experimental observations with up to five cans are presented. This device can serve as a model for phenomena concerned with atmospheric electricity.

Markus Zahn

1973-01-01T23:59:59.000Z

312

Voltage Control Devices on the IEEE 8500 Node Test Feeder  

SciTech Connect

The IEEE Test Cases provide researchers with distribution system models that can be used to validate new analytic methods. The newest of these models is the 8500-node test feeder which contains multiple devices for voltage control. In addition to a substation regulator there are multiple inline regulators as well as capacitor banks. This paper will discuss the detail in which voltage control devises should be modeled when examining large distribution systems. This discussion will include issues associated with power flow analysis for a single time step as well as for time series analysis.

Schneider, Kevin P.; Fuller, Jason C.

2010-01-06T23:59:59.000Z

313

Reduction of interference on substation low voltage wiring  

SciTech Connect

This paper describes test results and mitigation methods of electromagnetic interference (EMI) on control and low voltage circuits in substations caused by air disconnect switch operation. The tests are focused on a comparison between unshielded and shielded circuits from capacitively coupled voltage transformers (CCVT) and other equipment circuits in the vicinity. New test data are presented comparing unshielded and shielded cables and transient currents on all connections to the CCVT including the pedestal and ground strap. The paper gives a practical and understandable explanation of the causes of EMI in substations and how shielded cable and parallel ground conductors reduce interference. Design guidelines are listed in the Conclusion.

Gavazza, R.J. [Pacific Gas and Electric Co., San Francisco, CA (United States)] [Pacific Gas and Electric Co., San Francisco, CA (United States); Wiggins, C.M. [Carl M. Wiggins and Associates, Friendswood, TX (United States)] [Carl M. Wiggins and Associates, Friendswood, TX (United States)

1996-07-01T23:59:59.000Z

314

Conditions for Capacitor Voltage Regulation in a Five-Level Cascade Multilevel Inverter: Application to Voltage-Boost in a PM Drive  

E-Print Network (OSTI)

Conditions for Capacitor Voltage Regulation in a Five-Level Cascade Multilevel Inverter Abstract-- A cascade multilevel inverter is a power electronic device built to synthesize a desired AC voltage from several levels of DC voltages. Such inverters have been the subject of research in the last

Tolbert, Leon M.

315

Low Beam Voltage, 10 MW, L-Band Cluster Klystron  

SciTech Connect

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

Teryaev, V.; /Novosibirsk, IYF; Yakovlev, V.P.; /Fermilab; Kazakov, S.; /KEK, Tsukuba; Hirshfield, J.L.; /Yale U. /Omega-P, New Haven

2009-05-01T23:59:59.000Z

316

Power Grid Voltage Integrity Verification Department of ECE  

E-Print Network (OSTI)

Power Grid Voltage Integrity Verification Maha Nizam Department of ECE University of Toronto devgan@magma-da.com ABSTRACT Full-chip verification requires one to check if the power grid is safe, i of the circuit attached to the grid, thereby precluding early verification of the grid. We propose a power grid

Najm, Farid N.

317

Voltage Regulation through Smart Utilization of Potential Reactive Power Resources  

Science Journals Connector (OSTI)

The introduction of demand response concept, in addition to increment of penetration of distributed generation (DG) based on renewable energies, make opportunities for the novel control schemes to be integrated in power system on a smart grid framework. ... Keywords: Demand response, distributed generation, reactive power, renewable energy, smart grid, voltage control

H. Kazari; A. Abbaspour-Tehrani Fard; A. S. Dobakhshari; A. M. Ranjbar

2011-11-01T23:59:59.000Z

318

ORIGINAL ARTICLES Induced Transmembrane Voltage and Its Correlation  

E-Print Network (OSTI)

to investigate the correlation between DWm and molecular transport through an elec- troporated membrane to a voltage (electric potential difference) caused by a system of ion pumps and channels in the membrane, or electropermea- bilization, and permits transmembrane transport of mole- cules for which an intact membrane

Ljubljana, University of

319

Topical Review Voltage Dependence of the Na/K Pump  

E-Print Network (OSTI)

or ``ion well'' hy- pothesis. There are only two ways that net transport can be voltage dependent. Either of the external Na+ and K+ bind- ing sites within the membrane field. This access channel or ``ion well produced by applying a blocking Key words: Na,K-ATPase -- Membrane potential -- Access channel -- Ion well

Gadsby, David

320

Current isolating epitaxial buffer layers for high voltage photodiode array  

DOE Patents (OSTI)

An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Load Balancing in Wireless Sensor Networks using Kirchhoff's Voltage Law  

E-Print Network (OSTI)

Load Balancing in Wireless Sensor Networks using Kirchhoff's Voltage Law Stavros Toumpis Electrical balancing in wireless networks with a single class of traffic, focusing our attention on an important example, i.e., Wireless Sensor Networks. The analysis is based on the Wireless Minimum Cost Problem

Toumpis, Stavros

322

Power and Voltage Smooth Control of Doubly Fed Induction Generator  

Science Journals Connector (OSTI)

Doubly-fed induction generator (DFIG) is the leading in wind power technology currently. In this paper, decoupling control of DFIG is studied and a new energy storage device is used in the smooth control of DFIG system's power and voltage. This new method ... Keywords: Doubly fed induction generator, Energy storage device, Decoupling control

An-Ren Ma; Cai-Xia Wang; Zhi-Wen Zhou; Tao Wu

2012-07-01T23:59:59.000Z

323

Analysis on DFIG Wind Power System Low-Voltage Ridethrough  

Science Journals Connector (OSTI)

Due to the double fed induction generator’s (DFIG) advantage of controlling active and reactive power independently and partial power converter, DFIG is becoming a popular type of wind power generation system. Nowadays, the grid code demands that ... Keywords: VSCF, DFIG, LVRT, Crowbar, Voltage sags

Yulong Wang; Jianlin Li; Shuju Hu; Honghua Xu

2009-04-01T23:59:59.000Z

324

SVC Voltage Regulator Based on Fractional Order PID  

Science Journals Connector (OSTI)

Contradiction exist between rapid and smooth in the dynamic adjustment process of SVC, however, Fractional order PID controller has two degrees of freedom more than the integer order PID controller, and it has better control performance. This article ... Keywords: SVC, Fractional order PID, Voltage regulator, Oustaloup

Manyu Liu; Huaying Dong; Guishu Liang

2012-12-01T23:59:59.000Z

325

Way to reduce arc voltage losses in hybrid thermionic converters  

SciTech Connect

Experimental results are reported concerning the output and emission characteristics of the arc and hybrid regimes in a plane-parallel thermionic converter with Pt--Zr--O electrode pair. It is shown that arc voltage losses can be reduced to values below those obtainable in ordinary arc thermionic converters.

Tskhakaya, V.K.; Yarygin, V.I.

1982-03-01T23:59:59.000Z

326

Field Optimization of Three Dimensional High Voltage C. Trinitis  

E-Print Network (OSTI)

Field Optimization of Three Dimensional High Voltage Equipment C. Trinitis Lehrstuhl f The goal of finding an optimal electric field strength distribution for arbitrary three di­ mensional­ cal optimization algorithm. The package ob­ tained from these three components is then able

Stamatakis, Alexandros

327

High voltage gas insulated transmission line with continuous particle trapping  

DOE Patents (OSTI)

This invention provides a novel high voltage gas insulated transmission line utilizing insulating supports spaced at intervals with snap-in means for supporting a continuous trapping apparatus and said trapping apparatus having perforations and cutouts to facilitate trapping of contaminating particles and system flexibility.

Cookson, Alan H. (Pittsburgh, PA); Dale, Steinar J. (Monroeville, PA)

1983-01-01T23:59:59.000Z

328

High Voltage DC Transmission 2 1.0 Introduction  

E-Print Network (OSTI)

1 High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires on use of switching devices collectively referred to in the HVDC community as valves. Valves may be non. Fig. 1 There have been three types of devices for implementing HVDC converter circuits: mercury

McCalley, James D.

329

High-voltage supply for neutron tubes in well-logging applications  

DOE Patents (OSTI)

A high voltage supply is provided for a neutron tube used in well logging. The biased pulse supply of the invention combines DC and full pulse techniques and produces a target voltage comprising a substantial negative DC bias component on which is superimposed a pulse whose negative peak provides the desired negative voltage level for the neutron tube. The target voltage is preferably generated using voltage doubling techniques and employing a voltage source which generates bipolar pulse pairs having an amplitude corresponding to the DC bias level.

Humphreys, D.R.

1982-09-15T23:59:59.000Z

330

High-voltage nanosecond pulses in a low-pressure radio-frequency discharge  

Science Journals Connector (OSTI)

An influence of a high-voltage (3–17 kV) 20 ns pulse on a weakly-ionized low-pressure (0.1–10 Pa) capacitively coupled radiofrequency (RF) argon plasma is studied experimentally. The plasma evolution after pulse exhibits two characteristic regimes: a bright flash, occurring within 100 ns after the pulse (when the discharge emission increases by 2–3 orders of magnitude over the steady-state level), and a dark phase, lasting a few hundreds ?s (when the intensity of the discharge emission drops significantly below the steady-state level). The electron density increases during the flash and remains very large at the dark phase. 1D3V particle-in-cell simulations qualitatively reproduce both regimes and allow for detailed analysis of the underlying mechanisms. It is found that the high-voltage nanosecond pulse is capable of removing a significant fraction of plasma electrons out of the discharge gap, and that the flash is the result of the excitation of gas atoms, triggered by residual electrons accelerated in the electric field of immobile bulk ions. The secondary emission from the electrodes due to vacuum UV radiation plays an important role at this stage. High-density plasma generated during the flash provides efficient screening of the RF field (which sustains the steady-state plasma). This leads to the electron cooling and, hence, onset of the dark phase.

M. Y. Pustylnik; L. Hou; A. V. Ivlev; L. M. Vasilyak; L. Couëdel; H. M. Thomas; G. E. Morfill; V. E. Fortov

2013-06-10T23:59:59.000Z

331

PHILOSOPHY HONORS NOMINATION FORM The Philosophy Department offers an honors program for outstanding students in the major. Majors who have a 3.7 GPA in  

E-Print Network (OSTI)

PHILOSOPHY HONORS NOMINATION FORM The Philosophy Department offers an honors program for outstanding students in the major. Majors who have a 3.7 GPA in philosophy (3.25 overall) at the end if philosophy honors are to be awarded. Honors students are expected to maintain an average of 3.7 or better

332

Brain Research Foundation: Scientific Innovations Award in Neuroscience The Brain Research Foundation has invited Wayne State University to nominate one senior faculty member  

E-Print Network (OSTI)

Brain Research Foundation: Scientific Innovations Award in Neuroscience The Brain Research Foundation has invited Wayne State University to nominate one senior faculty member to submit a Letter the LOI, it must be opened in Adobe Acrobat). To learn more about the Brain Research Foundation, click

Finley Jr., Russell L.

333

Sodium/Phosphorus-Sulfur Cells I. Cell Performance Paul L. Ridgway,  

NLE Websites -- All DOE Office Websites (Extended Search)

Sodium/Phosphorus-Sulfur Cells Sodium/Phosphorus-Sulfur Cells I. Cell Performance Paul L. Ridgway, Frank R. McLarnon, and Elton J. Cairns* Energy and Environment Division, Lawrence Berkeley National Laboratory, and Department of Chemical Engineering, University of California, Berkeley, California 94720, USA ABSTRACT Sodium/°-alumina/phosphorus-sulfur cells utilizing P/S ratios of 0, 0.143, 0.332, and 1.17 at temperatures from 350 to 500°C were studied by measurement of the equilibrium cell voltages at open circuit, and the steady-state cell voltages at current densities up to 70 mA/cm2. States of charge, represented by sodium atom fraction in the P-S electrode, ranged from 0 to 0.4. Open-circuit voltages up to 2.65 V were measured. Theoretical specific energies up to 825 Wh/kg were cal-

334

Guidelines for Working at Voltages < 240 Volts  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidelines for Working at Voltages < 240 Volts Guidelines for Working at Voltages < 240 Volts February 4, 2005---DRAFT NOTE: Working hot is a LAST ALTERNATIVE. Electrical hot work is defined as: Working on or near exposed conducting parts that are or might become energized at 50V or more. Refer to Electrical Safety Flowchart for Working On or Near Live Parts. Engineered methods to prevent exposed sources of 50V and greater are to be implemented wherever practical. Only QUALIFIED PERSONNEL {as defined in NFPA 70E Article 110.6(D) 2004 edition} as authorized by the CAT/supervisor/division can perform such work. Refer to Qualified Electrical Worker Flow Chart. Training requirements: ES&H 114 (LOTO) / ES&H 375 (NFPA 70E) / ES&H 371 (electrical worker) - Observe Electrical Safe Work Practices. Refer to

335

Optimal Distributed Voltage Regulation in Power Distribution Networks  

E-Print Network (OSTI)

In this paper, we address the problem of voltage regulation in power distribution networks with deep-penetration of distributed energy resources (DERs), e.g., renewable-based generation, and storage-capable loads such as plug-in hybrid electric vehicles. We cast the problem as an optimization program, where the objective is to minimize the losses in the network subject to constraints on bus voltage magnitudes, limits on active and reactive power injections, transmission line thermal limits and losses. We provide sufficient conditions under which the optimization problem can be solved via its convex relaxation. Using data from existing networks, we show that the conditions are expected to be satisfied by most networks. We also provide an efficient distributed algorithm to solve the problem. The algorithm is asynchronous, with a communication topology that is the same as the electrical network topology. We illustrate the algorithm's performance in the IEEE 34-bus and the 123-bus feeder test systems.

Lam, Albert Y S; Dominguez-Garcia, Alejandro; Tse, David

2012-01-01T23:59:59.000Z

336

Analysis of Lightning-induced Voltages in Overhead Transmission Lines  

Science Journals Connector (OSTI)

Abstract In this work we study the coupling of lightning induced voltages in Overhead Transmission Lines .The study is led directly in the time domain with hold in account the effect of a finite conductivity of the soil. After discretization by the method so-called FDTD (Finite Difference Time Domain) of the lines equations excited by a lightning wave and the application in every node of the network in current and voltage, we deduct a equations system, of which the resolution permits us to deduct the induced electric quantities in every node of the network. In order to confirm our theoretical work, we present a set of applications that allows validating this study.

Mostefa. Boumaiza; Djamel. Labed

2014-01-01T23:59:59.000Z

337

Distribution capacitor automation that controls voltage and saves energy  

SciTech Connect

The Electric Distribution Business Line of Southern California Edison Company (SCE) has begun a program to improve the distribution system operations and electrical efficiency. The program, called the Distribution System Efficiency Enhancement Program (DSEEP), consists of five principal projects: Automated Switching, Circuit Lock-Out Alarming, Substation Monitoring and Control, Outage Management, and Distribution Capacitor Automation Project (DCAP). DCAP is the largest and most sophisticated of the projects being implemented. The project takes advantage of fine-tuning customer voltages for conservation voltage regulation (CVR) benefits as well as minimizes line losses by reducing unnecessary reactive power flow. DCAP can also help to increase transmission line and substation capacity by improving system power factor. The DCAP system takes advantage of the distributed processing capability of meters, capacitor controllers, radios, and substation processors. DCAP uses two-way packet radios and new electronic meters that read real-time customer voltages as well as energy consumption. The radios transmit customer meter voltage information and capacitor status to substation processors, where a control algorithm runs to determine which capacitors should be turned on or off. The objective of DCAP is to reduce over-all net energy transfer from the substation to the customer and meet system VAR requirements. SCE has tested the system on 66 circuit capacitors (including 3 substation capacitors) on 18 circuits served from two substations. The positive results of the DCAP demonstrations has led to an aggressive roll-out plan for system-wide implementation of automating over 7600 switched capacitors by year-end 1995.

Williams, B.R.

1994-12-31T23:59:59.000Z

338

Real time voltage control using emergency demand response in distribution system by integrating advanced metering infrastructure  

Science Journals Connector (OSTI)

In this paper an analytical study is reported to demonstrate the effects of demand response on distribution network voltages profile. Also a new approach for real time voltage control is proposed which uses emergency demand response program aiming at maintaining voltage profile in an acceptable range with minimum cost. This approach will be active in emergency conditions where in real time the voltages in some nodes leave their permissible ranges. These emergency conditions are Distributed Generation (DG) units and lines outage and unpredictable demand and renewable generations' fluctuations. The proposed approach does not need the load and renewable generation forecast data to regulate voltage. To verify the effectiveness and robustness of the proposed control scheme the proposed voltage control scheme is tested on a typical distribution network. The simulation results show the effectiveness and capability of the proposed real time voltage control model to maintain smart distribution network voltage in specified ranges in both normal and emergency conditions.

Alireza Zakariazadeh; Shahram Jadid

2014-01-01T23:59:59.000Z

339

Demand Response by Decentralized Device Control Based on Voltage Level  

Science Journals Connector (OSTI)

This paper introduces a distributed, self-organizing approach to load control based on voltage measurement. A local voltage measurement defines a Level of Service (LoS), which is balanced with the neighboring ...

Wilfried Elmenreich; Stefan Schuster

2014-01-01T23:59:59.000Z

340

Demand Side Management using VOLTAGE / DISTRIBUTION OPTIMIZATION Quality improvement & Peak reduction  

Science Journals Connector (OSTI)

In order to improve the quality of the electrical energy delivered at consumer households a Voltage Optimization Device (VOD) is introduced in each household. This device controls the output voltage accurately at...

N. H. M. Hofmeester; C. J. van de Water

1994-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

E-Print Network 3.0 - ac voltage standard Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

"volts, AC"), the "secondary" voltage is roughly 6 VAC. We shall use the "Universal Transformer... :" conversion of AC to DC You can use a diode to convert the AC voltage of the...

342

E-Print Network 3.0 - applied voltages ii Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

dc-link voltage error is applied to the fun... --In this paper, a new hybrid active power filter topology is presented. A higher-voltage, low-switching fre... - quency...

343

Advanced Gate Drive for the SNS High Voltage Converter Modulator  

SciTech Connect

SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

344

Linear inductive voltage adders (IVA) for advanced hydrodynamic radiography  

SciTech Connect

The electron beam which drifts through the multiple cavities of conventional induction linacs (LIA) is replaced in an IVA by a cylindrical metal conductor which extends along the entire length of the device and effectuates the addition of the accelerator cavity voltages. In the approach to radiography, the linear inductive voltage adder drives a magnetically immersed electron diode with a millimeter diameter cathode electrode and a planar anode/bremsstrahlung converter. Both anode and cathode electrodes are immersed in a strong (15--50 T) solenoidal magnetic field. The electron beam cross section is approximately of the same size as the cathode needle and generates a similar size, very intense x-ray beam when it strikes the anode converter. An IVA driven diode can produce electron beams of equal size and energy as a LIA but with much higher currents (40--50 kA versus 4--5 kA), simpler hardware and thus lower cost. The authors present here first experimental validations of the technology utilizing HERMES 3 and SABRE IVA accelerators. The electron beam voltage and current were respectively of the order of 10 MV and 40 kA. X-ray doses of up to 1 kR {at} 1 m and spot sizes as small as 1.7 mm (at 200 R doses) were measured.

Mazarakis, M.G.; Boyes, J.D.; Johnson, D.L. [and others

1998-09-01T23:59:59.000Z

345

Thermally-induced voltage alteration for integrated circuit analysis  

DOE Patents (OSTI)

A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.

Cole, Jr., Edward I. (Albuquerque, NM)

2000-01-01T23:59:59.000Z

346

Fiber optic current monitor for high-voltage applications  

DOE Patents (OSTI)

A current monitor which derives its power from the conductor being measured for bidirectionally measuring the magnitude of current (from DC to above 50 khz) flowing through a conductor across which a relatively high level DC voltage is applied, includes a pair of identical transmitter modules connected in opposite polarity to one another in series with the conductor being monitored, for producing from one module a first light signal having an intensity directly proportional to the magnitude of current flowing in one direction through the conductor during one period of time, and from the other module a second light signal having an intensity directly proportional to the magnitude of current flowing in the opposite direction through the conductor during another period of time, and a receiver located in a safe area remote from the high voltage area for receiving the first and second light signals, and converting the same to first and second voltage signals having levels indicative of the magnitude of current being measured at a given time.

Renda, George F. (Plainsboro, NJ)

1992-01-01T23:59:59.000Z

347

Development of microstructure and irradiation hardening of Zircaloy during low dose neutron irradiation at nominally 358 C  

SciTech Connect

Wrought Zircaloy-2 and Zircaloy-4 were neutron irradiated at nominally 358 C in the high flux isotope reactor (HFIR) at relatively low neutron fluences between 5.8 1022 and 2.9 1025 n/m2 (E > 1 MeV). The irradiation hardening and change in microstructure were characterized following irradiation using tensile testing and examinations of microstructure using Analytical Electron Microscopy (AEM). Small increments of dose (0.0058, 0.11, 0.55, 1.08, and 2.93 1025 n/m2) were used in the range where the saturation of irradiation hardening is typically observed so that the role of microstructure evolution and hai loop formation on irradiation hardening could be correlated. An incubation dose between 5.8 1023 and 1.1 1024 n/m2 was needed for loop nucleation to occur that resulted in irradiation hardening. Increases in yield strength were consistent with previous results in this temperature regime, and as expected less irradiation hardening and lower hai loop number density values than those generally reported in literature for irradiations at 260 326 C were observed. Unlike previous lower temperature data, there is evidence in this study that the irradiation hardening can decrease with dose over certain ranges of fluence. Irradiation induced voids were observed in very low numbers in the Zircaloy-2 materials at the highest fluence.

Cockeram, Brian V [Bechtel-Bettis, Inc.; Smith, Richard W [Bechtel-Bettis, Inc.; Leonard, Keith J [ORNL; Byun, Thak Sang [ORNL; Snead, Lance Lewis [ORNL

2011-01-01T23:59:59.000Z

348

An Open Question about Dependency of Life Time of Hardware Components and Dynamic Voltage Scaling  

E-Print Network (OSTI)

Open question about Dependency of Life Time of Hardware Components and Dynamic Voltage Scaling (A primary idea)

Jaberi, Nasrin

2012-01-01T23:59:59.000Z

349

Limiting discharge voltage of a capacitive energy store in a subway car  

Science Journals Connector (OSTI)

A method is proposed for calculating the limiting discharge voltage of a capacitive energy store in a subway car.

G. G. Ryabtsev; I. A. Ermakov

2012-12-01T23:59:59.000Z

350

Radio-Frequency Interference (RFI) From Extra-High-Voltage (EHV) Transmission Lines  

E-Print Network (OSTI)

discharges are a design issue. Extra-high-voltage (EHV) transmission lines have operating voltages of 345 kV building a 345-kV transmission line from Red Hill, NM to Deming, NM which would run east along US60 to its with respect to radio noise: (1) lines with voltages below 70 kV and (2) lines with voltages above 110 kV

Ellingson, Steven W.

351

Topology optimization-based distribution design of actuation voltage in static shape control of plates  

Science Journals Connector (OSTI)

This paper investigates the optimal spatial distribution of single-channel actuation voltage in static structural shape control problem. It is pointed out that single-channel actuation voltage input for shape control applications is of practical importance ... Keywords: Shape control, Single channel, Topology optimization, Voltage distribution

Zhan Kang; Liyong Tong

2008-10-01T23:59:59.000Z

352

Impact of Wind Generation Variability on Voltage Profile of Radial Power Systems  

Science Journals Connector (OSTI)

This paper provides the results of a study conducted to assess the impacts of the "wind generation variability" on the voltage profile in a small-scale radial power system. The power network has been modeled using one of the well-known simulation programs ... Keywords: Wind Generation, Voltage Profile, Power Grids, Voltage Impacts, Minimum Singular Value, SSV index

M. O. Alruwaili; M. Y. Vaziri; S. Vadhva; S. Vaziri

2013-04-01T23:59:59.000Z

353

Statistical Estimation of Leakage-Induced Power Grid Voltage Drop Considering Within-Die Process Variations  

E-Print Network (OSTI)

Statistical Estimation of Leakage-Induced Power Grid Voltage Drop Considering Within-Die Process the power grid, the grid develops large voltage drops, which is an unavoidable background level of noise on the grid. We develop techniques for estimation of the statistics of the leakage-induced power grid voltage

Najm, Farid N.

354

Statistical Estimation of LeakageInduced Power Grid Voltage Drop Considering WithinDie Process Variations #  

E-Print Network (OSTI)

Statistical Estimation of Leakage­Induced Power Grid Voltage Drop Considering Within­Die Process the power grid, the grid develops large voltage drops, which is an unavoidable background level of noise on the grid. We develop techniques for estimation of the statistics of the leakage­induced power grid voltage

Najm, Farid N.

355

Statistical Estimation of Circuit Timing Vulnerability Due to Leakage-Induced Power Grid Voltage Drop  

E-Print Network (OSTI)

Statistical Estimation of Circuit Timing Vulnerability Due to Leakage-Induced Power Grid Voltage voltage drops on the power grid that can affect circuit timing. We propose a statistical analysis supply voltage to circuit devices is referred to as the power grid. The consequences of power grid

Najm, Farid N.

356

Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines  

E-Print Network (OSTI)

Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines: State-of-the-Art Review deals with low-voltage ride-through (LVRT) capability of wind turbines (WTs) and in particular those as to index some emerging solutions. Index Terms--Wind turbine, doubly-fed induction generator, low voltage

Paris-Sud XI, Université de

357

Research on fuzzy logic based dynamic boundary voltage and reactive power integrated control method  

Science Journals Connector (OSTI)

Aiming at the existing problems of conventional substation voltage and reactive power integrated control method, a new fuzzy logic based dynamic reactive power boundary voltage and reactive power integrated control method is proposed. Fuzzy logic control ... Keywords: dynamic boundary, fuzzy logic, reactive power, voltage

Zigang Xu; Fei Wang

2009-06-01T23:59:59.000Z

358

DSP IMPLEMENTATION OF DC VOLTAGE REGULATION USING ADAPTIVE CONTROL FOR 200 KW 62000 RPM  

E-Print Network (OSTI)

to control the DC voltage for 200 kW induction generator rated at a speed of 62000 RPM under different load to regulate the DC voltage for high speed induction generators rated from 5 kW to 200 kW. ii #12DSP IMPLEMENTATION OF DC VOLTAGE REGULATION USING ADAPTIVE CONTROL FOR 200 KW 62000 RPM INDUCTION

Wu, Thomas

359

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares in the  

E-Print Network (OSTI)

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares high-voltage transformer spares throughout the electric grid to mitigate the risk of random transformer-voltage transformers are an integral part of the electric transmission system. A catas- trophic transformer failure

Powell, Warren B.

360

Application-Directed Voltage Scaling Johan Pouwelse, Koen Langendoen, and Henk Sips  

E-Print Network (OSTI)

--Clock (and voltage) scheduling is an important tech- nique to reduce the energy consumption of processors that sup- port voltage scaling. It is difficult, however, to achieve good re- sults using only statistics to the scheduler control- ling the clock speed and processor voltage. This paper describes our Energy Priority

Pouwelse, Johan

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power Filter Applications  

E-Print Network (OSTI)

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power voltage-source inverters connected in series (known as cascaded hybrid asymmetric multilevel inverter voltage application due to semiconductor constraint. In order to achieve higher power level, hybrid

Catholic University of Chile (Universidad Católica de Chile)

362

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 57, NO. 10, OCTOBER 2010 3431 A Universal Grid-Connected Fuel-Cell Inverter for  

E-Print Network (OSTI)

. INTRODUCTION THE utilization of fuel cells for distributed power gen- eration requires the development of a low-cost characteristics: 1) output-voltage regulation for a wide variation in the output voltage of the fuel-cell stack; 2 the fuel-cell stack and the application load. The conventional scheme, shown in Fig. 1(a), achieves

Mazumder, Sudip K.

363

FUEL CELLS – SOLID OXIDE FUEL CELLS | Systems  

Science Journals Connector (OSTI)

In this article, some basic arrangements of solid oxide fuel cell (SOFC) systems are described, starting with atmospheric systems using a catalytic burner or a thermal burner and anode gas recycling. For illustrating the potential electrical efficiency of SOFC systems, their combination with a gas turbine and also with a steam turbine (ST) are described. To be able to evaluate the potential of the different systems, first the essential efficiencies relevant to fuel cell systems are defined and then the basics of calculating energy balance are illustrated. Equations are given to describe, for example, the effect of fuel recycling on system fuel utilization and of internal reforming on the necessary air flow for cooling the stack. It is obvious that electrical efficiency depends strongly on cell voltage and fuel utilization. In the case of cells that operate with a high fuel utilization at cell voltages of 800 mV, a net electrical efficiency above 55% can be achieved. The combination in a pressurized system with a gas turbine enables efficiencies of up to 70% and combining this system with an additional ST allows efficiencies of up to 75%. However, an investigation into the size of these \\{STs\\} shows that such combined systems make sense only above a gas input of 10 MW.

L. Blum; E. Riensche

2009-01-01T23:59:59.000Z

364

Determining Outdoor CPV Cell Temperature: Preprint  

SciTech Connect

An accurate method is needed for determining cell temperature when measuring CPV modules outdoors. It has been suggested that cell temperature can be calculated though a procedure that shutters sunlight to the cells while measuring the transients in open-circuit voltage (Voc) and heat sink temperature. This paper documents application of this shutter procedure to multiple CPV modules at NREL. The challenges and limitations are presented along with an alternate approach to measuring CPV cell operating temperature.

Muller, M.; Deline, C.; Marion, B.; Kurtz, S.; Bosco, N.

2011-07-01T23:59:59.000Z

365

Solar energy conversion by chloroplast photoelectrochemical cells  

Science Journals Connector (OSTI)

... the photochemical cell has proved advantageous because of their ease of preparation and their power conversion efficiency of close to 1 %. Fig. l Time course of potential development. ... h even after the light was turned off, illustrated the system's ability to store energy. The ability of the cell to generate a voltage is equivalent to a generator ...

Ravindra Bhardwaj; Rong L. Pan; Elizabeth L. Gross

1981-01-29T23:59:59.000Z

366

The Application of Droop-Control in Distributed Energy Resources to Extend the Voltage Collapse Margin  

SciTech Connect

The growth in distributed energy resources has the potential to reduce system stresses caused by transmission grid congestion by supplying power and voltage regulation closer to load centers. However, the additional voltage regulation provided by these resources can mask the onset of voltage collapse. Local voltage support flattens the slope in the upper region of the power-voltage nose curve. Coordinating voltage-regulation behavior with the droop-control scheme in distributed resources improves the observation of voltage collapse margins. Incorporating distributed resource models in the continuation power flow analysis, allows the exploration of the power transfer gains by the application of distributed resources. The analysis provides insight to the impact of droop control on the behavior of the power-voltage curve and voltage collapse. The analysis is applied to a fixed speed induction generator wind farm with separate reactive compensation and the interconnection to the local power system. Results reveal that coordinating the droop control strategy allows the distributed resource to significantly increase the voltage collapse margin without hiding the threat of voltage stability problems.

Henry, Shawn D. [Florida State University; Rizy, D Tom [ORNL; Baldwin, Thomas L [Florida State University; Kueck, John D [ORNL; Li, Fangxing [ORNL

2008-01-01T23:59:59.000Z

367

High-voltage R-F feedthrough bushing  

DOE Patents (OSTI)

Described is a multi-element, high voltage radio frequency bushing for transmitting rf energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.

Grotz, G.F.

1982-09-03T23:59:59.000Z

368

Outdoor PV Module Degradation of Current-Voltage Parameters: Preprint  

SciTech Connect

Photovoltaic (PV) module degradation rate analysis quantifies the loss of PV power output over time and is useful for estimating the impact of degradation on the cost of energy. An understanding of the degradation of all current-voltage (I-V) parameters helps to determine the cause of the degradation and also gives useful information for the design of the system. This study reports on data collected from 12 distinct mono- and poly-crystalline modules deployed at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. Most modules investigated showed < 0.5%/year decrease in maximum power due to short-circuit current decline.

Smith, R. M.; Jordan, D. C.; Kurtz, S. R.

2012-04-01T23:59:59.000Z

369

Self-monitoring high voltage transmission line suspension insulator  

DOE Patents (OSTI)

A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

Stemler, Gary E. (Vancouver, WA); Scott, Donald N. (Vancouver, WA)

1981-01-01T23:59:59.000Z

370

Voltage sensor with fiber Fabry-Perot interferometer  

E-Print Network (OSTI)

with smaller strain constants, a larger voltage must be applied to get a 2x round trip phase shift. Hence, a longer FFPI is needed to get higher resolution. 16 A plate type PZT was selected because it's more convenient to attach to a thermo-electric cooler... in electron-beam evaporation system, they can be spliced to uncoated fibers, which also have cleaved end surfaces. The basic configuration for this Siecor Model M 67 fusion splicer is shown in fig. 12. A electric arc is initiated between the electrodes...

Wann, Been-Huey

1992-01-01T23:59:59.000Z

371

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

1998-01-01T23:59:59.000Z

372

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

Druce, R.L.; Kirbie, H.C.; Newton, M.A.

1998-06-30T23:59:59.000Z

373

Arthur J. Dellinger, Sr. , nomination. Hearing before the Committee on Energy and Natural Resources, United States Senate, Ninety-Seventh Congress, Second Session, June 28, 1982  

SciTech Connect

A one-day confirmation hearing on the nomination of Arthur J. Dellinger, Sr. as DOE Deputy Inspector General (IG) focused on his ability and willingness to perform the duties and on his technical qualifications. The Deputy IG assists the IG in fraud detection and prevention, department audits to promote economy and efficiency, and policy recommendations. An informational statement covering his background, financial disclosure, and correspondence follows Mr. Dellinger's testimony. (DCK)

Not Available

1982-01-01T23:59:59.000Z

374

Anomalous Hysteresis in Perovskite Solar Cells  

Science Journals Connector (OSTI)

Anomalous Hysteresis in Perovskite Solar Cells ... Even for silicon solar cells, hysteresis in the current-voltage curves can occur if the bias is swept extremely fast, with complete scans performed in less than 2 to 44 ms depending on the precise cell architecture. ... We will discuss the three predominant perovskite solar-cell architectures in this letter: (i) planar heterojunction solar cells with no mesoporous oxide,(7, 17) (ii) perovskite-sensitized solar cells fabricated on mesoporous TiO2,(1, 3) and (iii) meso-superstrutured solar cells (MSSCs) which employ mesoporous Al2O3 as an inert scaffold in place of the TiO2. ...

Henry J. Snaith; Antonio Abate; James M. Ball; Giles E. Eperon; Tomas Leijtens; Nakita K. Noel; Samuel D. Stranks; Jacob Tse-Wei Wang; Konrad Wojciechowski; Wei Zhang

2014-03-24T23:59:59.000Z

375

Expected dose for the nominal scenario class in the 2008 performance assessment for the proposed high-level radioactive waste repository at Yucca Mountain, Nevada  

Science Journals Connector (OSTI)

Abstract Extensive work has been carried out by the U.S. Department of Energy (DOE) in the development of a proposed geologic repository at Yucca Mountain (YM), Nevada, for the disposal of high-level radioactive waste. In support of this development and an associated license application to the U.S. Nuclear Regulatory Commission (NRC), the DOE completed an extensive performance assessment (PA) for the proposed YM repository in 2008. This presentation describes the determination of expected (mean) dose to the reasonably maximally exposed individual (RMEI) specified in the NRC regulations for the YM repository for the nominal scenario class (i.e., under nominal or undisturbed conditions) in the 2008 YM PA. The following topics are addressed: (i) properties of the nominal scenario class and the determination of dose and expected (mean) dose to the RMEI, (ii) uncertainty in dose and resultant expected (mean) dose to the RMEI, (iii) expected (mean) dose to the RMEI from individual radionuclides, and (iv) numerical stability of the sampling-based procedure used to estimate the expected (mean) dose to the RMEI. The present paper is part of a special issue of Reliability Engineering and System Safety devoted to the 2008 YM PA; additional papers in the issue describe other aspects of the 2008 YM PA.

J.C. Helton; C.W. Hansen; C.J. Sallaberry

2014-01-01T23:59:59.000Z

376

Studies on High Voltage Lithium Rich MNC Composite Cathodes  

Energy.gov (U.S. Department of Energy (DOE))

2012 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

377

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Energy.gov (U.S. Department of Energy (DOE))

2012 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

378

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Energy.gov (U.S. Department of Energy (DOE))

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

379

Cathode Synthesis and Voltage Fade: Designed Solutions Based on Theory  

Energy.gov (U.S. Department of Energy (DOE))

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

380

High Voltage Electrolytes for Li-ion Batteries  

Energy.gov (U.S. Department of Energy (DOE))

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

complete Timeline Budget Barriers Partners Overview * Barriers addressed: - A. Battery cost - C. Performance: Energy Density - E. Lifetime * Targets - prototype cells...

382

Methods, systems and apparatus for controlling third harmonic voltage when operating a multi-space machine in an overmodulation region  

SciTech Connect

Methods, system and apparatus are provided for controlling third harmonic voltages when operating a multi-phase machine in an overmodulation region. The multi-phase machine can be, for example, a five-phase machine in a vector controlled motor drive system that includes a five-phase PWM controlled inverter module that drives the five-phase machine. Techniques for overmodulating a reference voltage vector are provided. For example, when the reference voltage vector is determined to be within the overmodulation region, an angle of the reference voltage vector can be modified to generate a reference voltage overmodulation control angle, and a magnitude of the reference voltage vector can be modified, based on the reference voltage overmodulation control angle, to generate a modified magnitude of the reference voltage vector. By modifying the reference voltage vector, voltage command signals that control a five-phase inverter module can be optimized to increase output voltages generated by the five-phase inverter module.

Perisic, Milun; Kinoshita, Michael H; Ranson, Ray M; Gallegos-Lopez, Gabriel

2014-06-03T23:59:59.000Z

383

PEM fuel cell monitoring system  

DOE Patents (OSTI)

Method and apparatus for monitoring the performance of H.sub.2 --O.sub.2 PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H.sub.2 sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken.

Meltser, Mark Alexander (Pittsford, NY); Grot, Stephen Andreas (West Henrietta, NY)

1998-01-01T23:59:59.000Z

384

PEM fuel cell monitoring system  

DOE Patents (OSTI)

Method and apparatus are disclosed for monitoring the performance of H{sub 2}--O{sub 2} PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H{sub 2} sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken. 2 figs.

Meltser, M.A.; Grot, S.A.

1998-06-09T23:59:59.000Z

385

Bi-directional power control system for voltage converter  

DOE Patents (OSTI)

A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

Garrigan, Neil Richard (Niskayuna, NY); King, Robert Dean (Schenectady, NY); Schwartz, James Edward (Slingerlands, NY)

1999-01-01T23:59:59.000Z

386

Control of Analyte Electrolysis in Electrospray Ionization Mass Spectrometry Using Repetitively Pulsed High Voltage  

SciTech Connect

Analyte electrolysis using a repetitively pulsed high voltage ion source was investigated and compared to that using a regular, continuously operating direct current high voltage ion source in electrospray ionization mass spectrometry. The extent of analyte electrolysis was explored as a function of the length and frequency of the high voltage pulse using the model compound reserpine in positive ion mode. Using +5 kV as the maximum high voltage amplitude, reserpine was oxidized to its 2, 4, 6 and 8-electron oxidation products when direct current high voltage was employed. In contrast, when using a pulsed high voltage, oxidation of reserpine was eliminated by employing the appropriate high voltage pulse length and frequency. This effect was caused by inefficient mass transport of the analyte to the electrode surface during the duration of the high voltage pulse and the subsequent relaxation of the emitter electrode/ electrolyte interface during the time period when the high voltage was turned off. This mode of ESI source operation allows for analyte electrolysis to be quickly and simply switched on or off electronically via a change in voltage pulse variables.

Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

2011-01-01T23:59:59.000Z

387

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators  

E-Print Network (OSTI)

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators General Description The LM139 series consists of four independent precision voltage comparators with an offset voltage clock timers; multivibrators and high voltage digital logic gates. The LM139 series was designed

Lanterman, Aaron

388

Recombination in polymer-fullerene bulk heterojunction solar cells  

Science Journals Connector (OSTI)

Recombination of photogenerated charge carriers in polymer bulk heterojunction (BHJ) solar cells reduces the short circuit current (Jsc) and the fill factor (FF). Identifying the mechanism of recombination is, therefore, fundamentally important for increasing the power conversion efficiency. Light intensity and temperature-dependent current-voltage measurements on polymer BHJ cells made from a variety of different semiconducting polymers and fullerenes show that the recombination kinetics are voltage dependent and evolve from first-order recombination at short circuit to bimolecular recombination at open circuit as a result of increasing the voltage-dependent charge carrier density in the cell. The “missing 0.3 V” inferred from comparison of the band gaps of the bulk heterojunction materials and the measured open-circuit voltage at room-temperature results from the temperature dependence of the quasi-Fermi levels in the polymer and fullerene domains—a conclusion based on the fundamental statistics of fermions.

Sarah R. Cowan; Anshuman Roy; Alan J. Heeger

2010-12-16T23:59:59.000Z

389

NETL: Fuel Cells/SECA News - Archive  

NLE Websites -- All DOE Office Websites (Extended Search)

Fuel Cells/Solid State Energy Conversion Alliance (SECA) Fuel Cells/Solid State Energy Conversion Alliance (SECA) News Archive SECA Workshop Proceedings, Peer Reviews, and Annual Reports 2013 Archive 2012 Archive 2011 Archive Previous Highlights FuelCell Energy's Stack Boosts Power and Minimizes Degradation FuelCell Energy has developed a new solid oxide fuel cell stack design that boosts the overall power output of the fuel cell stack by nearly 50%. FuelCell Energy also achieved a voltage degradation rate of 1.3% per 1000 hours after testing the fuel cells for 26,000 hours of operation. This breakthrough by FuelCell Energy of greater power from the fuel cell stack while minimizing fuel cell degradation pushes it further towards meeting SECA's goal of a market ready, affordable solid oxide fuel cell ready by the year 2010. (5/05)

390

Local Voltage Support from Distributed Energy Resources to Prevent Air Conditioner Motor Stalling  

SciTech Connect

Microgrid voltage collapse often happens when there is a high percentage of low inertia air-conditioning (AC) motors in the power systems. The stalling of the AC motors results in Fault Induced Delayed Voltage Recovery (FIDVR). A hybrid load model including typical building loads, AC motor loads, and other induction motor loads is built to simulate the motoring stalling phenomena. Furthermore, distributed energy resources (DE) with local voltage support capability are utilized to boost the local bus voltage during a fault, and prevent the motor stalling. The simulation results are presented. The analysis of the simulation results show that local voltage support from multiple DEs can effectively and economically solve the microgrid voltage collapse problem.

Baone, Chaitanya A [ORNL] [ORNL; Xu, Yan [ORNL] [ORNL; Kueck, John D [ORNL] [ORNL

2010-01-01T23:59:59.000Z

391

Bright and fast voltage reporters across the visible spectrum via electrochromic FRET (eFRET)  

E-Print Network (OSTI)

We present a palette of brightly fluorescent genetically encoded voltage indicators (GEVIs) with excitation and emission peaks spanning the visible spectrum, sensitivities from 6 - 10% Delta F/F per 100 mV, and half-maximal response times from 1 - 7 ms. A fluorescent protein is fused to an Archaerhodopsin-derived voltage sensor. Voltage-induced shifts in the absorption spectrum of the rhodopsin lead to voltage-dependent nonradiative quenching of the appended fluorescent protein. Through a library screen, we identified linkers and fluorescent protein combinations which reported neuronal action potentials in cultured rat hippocampal neurons with a single-trial signal-to-noise ratio from 6.6 to 11.6 in a 1 kHz imaging bandwidth at modest illumination intensity. The freedom to choose a voltage indicator from an array of colors facilitates multicolor voltage imaging, as well as combination with other optical reporters and optogenetic actuators.

Zou, Peng; Douglass, Adam D; Hochbaum, Daniel R; Brinks, Daan; Werley, Christopher A; Harrison, D Jed; Campbell, Robert E; Cohen, Adam E

2014-01-01T23:59:59.000Z

392

Seismic vulnerability assessment of a high voltage disconnect switch  

Science Journals Connector (OSTI)

Abstract This paper deals with the seismic vulnerability of high voltage equipment typically installed in electric substations. In particular, the seismic response of a 380 kV vertical disconnect switch has been investigated based on the results of an experimental campaign carried out at Roma Tre University. According to a series of non-linear analyses, the influence of the most significant parameters on the seismic behavior of this apparatus has been analyzed and the corresponding fragility curves have been evaluated by using the Effective Fragility Analysis method. The results showed a limited vulnerability of the disconnect switch, whose most critical parts are the bottom joint of the ceramic support column and the steel column base.

Fabrizio Paolacci; Renato Giannini; Silvia Alessandri; Gianmarco De Felice

2014-01-01T23:59:59.000Z

393

Discriminator based on voltage comparator for nuclear physics research  

SciTech Connect

This paper describes a simple discriminator of low-level pulses with integral discrimination based on a K521SA3 comparator. The discriminator can be used to record pulses with durations of greater than or equal to 0.1 usec and amplitudes of greater than or equal to 1 mV. the input-pulse amplitude must not exceed the supply-voltage amplitude. A schematic diagram of the discriminator is given. For operation of the NGR spectrometer in the constant-velocity mode, the comparator was gated by the bipolar vibrator-velocity signal. The described circuit is reliable under laboratory conditions and its use is promising in multi-input systems such as those with multisection coordinate detectors.

Vorob'ev, V.A.; Kiselev, A.A.; Kuz'min, R.N.

1985-12-01T23:59:59.000Z

394

Effect of DC voltage pulses on memristor behavior.  

SciTech Connect

Current knowledge of memristor behavior is limited to a few physical models of which little comprehensive data collection has taken place. The purpose of this research is to collect data in search of exploitable memristor behavior by designing and implementing tests on a HP Labs Rev2 Memristor Test Board. The results are then graphed in their optimal format for conceptualizing behavioral patterns. This series of experiments has concluded the existence of an additional memristor state affecting the behavior of memristors when pulsed with positively polarized DC voltages. This effect has been observed across multiple memristors and data sets. The following pages outline the process that led to the hypothetical existence and eventual proof of this additional state of memristor behavior.

Evans, Brian R.

2013-10-01T23:59:59.000Z

395

Voltage flicker prediction for two simultaneously operated ac arc furnaces  

SciTech Connect

An EMTP-based arc furnace model was developed for evaluation of flicker concerns associated with supplying a large integrated steel mill as they go from one to two furnace operation and as system changes are implemented that will affect the short circuit capacity at the 230 kV power supply substation. The model includes a dynamic arc representation which is designed to be characteristic of the initial portions of the melt cycle when the arc characteristics are the most variable (worst flicker conditions). The flicker calculations are verified using previous measurements with one furnace operation. Flicker simulations were then performed to evaluate a variety of different possible system strengths with both one and two furnaces in operation. The primary flicker measure used for this study is the unweighted rms value of the fluctuation envelope, expressed as a percentage of the rms line-to-ground voltage magnitude.

Tang, L. [ABB Power T and D Co., Inc., Raleigh, NC (United States)] [ABB Power T and D Co., Inc., Raleigh, NC (United States); Kolluri, S. [Entergy Services, New Orleans, LA (United States)] [Entergy Services, New Orleans, LA (United States); McGranaghan, M.F. [Electrotek Concepts, Inc., Knoxville, TN (United States)] [Electrotek Concepts, Inc., Knoxville, TN (United States)

1997-04-01T23:59:59.000Z

396

Voltage spike detection in high field superconducting accelerator magnets  

SciTech Connect

A measurement system for the detection of small magnetic flux changes in superconducting magnets, which are due to either mechanical motion of the conductor or flux jump, has been developed at Fermilab. These flux changes are detected as small amplitude, short duration voltage spikes, which are {approx}15mV in magnitude and lasts for {approx}30 {micro}sec. The detection system combines an analog circuit for the signal conditioning of two coil segments and a fast data acquisition system for digitizing the results, performing threshold detection, and storing the resultant data. The design of the spike detection system along with the modeling results and noise analysis will be presented. Data from tests of high field Nb{sub 3}Sn magnets at currents up to {approx}20KA will also be shown.

Orris, D.F.; Carcagno, R.; Feher, S.; Makulski, A.; Pischalnikov, Y.M.; /Fermilab

2004-12-01T23:59:59.000Z

397

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents (OSTI)

A process for fabricating sequential inductors and varistor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varistor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process. 6 figs.

Cooper, G.A.

1994-10-04T23:59:59.000Z

398

High-speed, sub-pull-in voltage MEMS switching.  

SciTech Connect

We have proposed and demonstrated MEMS switching devices that take advantage of the dynamic behavior of the MEMS devices to provide lower voltage actuation and higher switching speeds. We have explored the theory behind these switching techniques and have demonstrated these techniques in a range of devices including MEMS micromirror devices and in-plane parallel plate MEMS switches. In both devices we have demonstrated switching speeds under one microsecond which has essentially been a firm limit in MEMS switching. We also developed low-loss silicon waveguide technology and the ability to incorporate high-permittivity dielectric materials with MEMS. The successful development of these technologies have generated a number of new projects and have increased both the MEMS switching and optics capabilities of Sandia National Laboratories.

Spahn, Olga Blum; Brewer, Steven; Olsson, Roy H.; Bogart, Gregory R.; Luck, David L.; Watts, Michael R.; Shaw, Michael J.; Nielson, Gregory N.; Resnick, Paul James; Tigges, Christopher P.; Grossetete, Grant David

2008-01-01T23:59:59.000Z

399

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents (OSTI)

A process for fabricating sequential inductors and varactor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varactor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process.

Cooper, Gregory A. (346 Primrose Dr., Pleasant Hill, CA 94523)

1994-01-01T23:59:59.000Z

400

Summary of multiterminal high-voltage direct current transmission technology  

SciTech Connect

This report summarizes the present state of multiterminal (MT) high-voltage direct current (HVDC) power transmission. The purpose is to reassess the need for HVDC circuit breakers and to identify needed research for MT HVDC. The fundamentals of this technology are presented, and previous research and development is reviewed. Although no MT HVDC systems have yet been built, many concepts have been proposed. Some require a dc breaker, and others do not. Both options have advantages and disadvantages for various applications, so the selection will depend on the proposed application. Research is needed to define operating characteristics of various MT HVDC systems. In some applications, dc breakers will be useful, so research into HVDC interruption should continue. Also, dc fault detection and control algorithms for MT systems should be studied.

Biggs, R.B.; Jewell, W.T.

1984-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Sacramento Area Voltage Support Draft Environmental Impact Statement  

SciTech Connect

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the ''National Environmental Policy Act'' (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2002-11-15T23:59:59.000Z

402

Sacramento Area Voltage Support Final Environmental Impact Statement  

SciTech Connect

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the National Environmental Policy Act (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: (1) Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; (2) Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and (3) Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2003-09-19T23:59:59.000Z

403

Investigation of dc precise voltage sources for use as Zener transport standard  

SciTech Connect

20 precise compact voltage sources based on zener diodes were manufactured. These sources were under investigation at measuring system in NPO VNIIFTRI during the year. A few sources with voltage drift less than 5 ppm per year and noise level lower than 100 nV in the frequency band of 0,01-10 Hz were selected for manufacturing of 4-channels dc voltage transportable reference standard. This reference standard was investigated by Russian 1-V Josephson systems.

Karpov, O.V.; Shulga, V.M.; Shakirzyanova, F.R. [National Scientifical and Research Institute for Physical Technical and Radiotechnical Measurements, Moscow (Russian Federation)

1994-12-31T23:59:59.000Z

404

February 2008 Rev 21 1/49 Very low drop voltage regulators with inhibit  

E-Print Network (OSTI)

. In the three terminal configuration the device has the same electrical performance, but is fixed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 4. Dropout voltage vs output current

Berns, Hans-Gerd

405

Electric Field Calculations on Dry-Type Medium Voltage Current Transformers.  

E-Print Network (OSTI)

??This research presents potential and electric field calculations on medium voltage (MV) epoxy insulated outdoor current transformers (CTs) using a numeri-cal calculation approach. Two designs… (more)

Lakshmichand Jain, Sandeep Kumar

2012-01-01T23:59:59.000Z

406

Object Oriented Safety Analysis of an Extra High Voltage Substation Bay  

Science Journals Connector (OSTI)

Experiences of application of the object oriented approach to safety analysis of an extra high voltage substation bay are presented. As the first step...

Bartosz Nowicki; Janusz Górski

1998-01-01T23:59:59.000Z

407

Dynamic voltage-current characteristics for a water jet plasma arc  

SciTech Connect

A virtual instrument technology is used to measure arc current, arc voltage, dynamic V-I characteristics, and nonlinear conductance for a cone-shaped water jet plasma arc under ac voltage. Experimental results show that ac arc discharge mainly happens in water vapor evaporated from water when heated. However, due to water's cooling effect and its conductance, arc conductance, reignition voltage, extinguish voltage, and current zero time are very different from those for ac arc discharge in gas work fluid. These can be valuable to further studies on mechanism and characteristics of plasma ac discharge in water, and even in gas work fluid.

Yang Jiaxiang; Lan Sheng; Xu Zuoming [College of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin, Heilongjiang 150040 (China)

2008-05-05T23:59:59.000Z

408

Lab Trials of an Electricity Transmission Line Voltage Sensor Based on Thermally Poled Silica Fibre  

Science Journals Connector (OSTI)

Voltage sensing using helically coiled lengths of thermally poled twin-hole silica optical fibre is presented. Lab accuracy test results showing good linearity and signal to noise...

Michie, Andrew M; Hambley, Philip; Bassett, Ian M; Haywood, John H; Henry, Peter; Ingram, John

409

The design of an A-C voltage regulator using a Wein Bridge detector  

E-Print Network (OSTI)

equipment, which in turn demands a mox'e closely regulated power supply. In satisfying these demands there have been many kinds of voltage regulators designed, constructed, and needs A voltage regulator oonsists essentially of two pax'ts, the "detectox...-V, 424-8, 470 3, 499-503 1950 4. Patchett, G. N. , "The Theory of Nonlinear Bridge Circuit Applied to Voltage Stabilizers, " J. I . E. E . , Vol. 93, Pt. III, p. 18 (1948). 5. Choudbury, J. K. t Das Gupta, S. C. , and Sen, P. C, , "An A-C Voltage...

Brown, Richard True

2012-06-07T23:59:59.000Z

410

Solid State NMR Studies and Local Structure of Voltage Fade Materials  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

with the Voltage Fade Team Michael Slater, Jason Croy, Kevin Gallagher, Christopher Johnson, Yang Ren DOE Vehicle Technologies Program Annual Merit Review Arlington, VA May 13 -...

411

Consideration of 34. 5 KV as an in-plant voltage for a large industrial user  

SciTech Connect

Traditionally, the in-plant distribution voltage for a large refinery or petrochemical complex has been 13.8 kV. Selection of this voltage level was dictated primarily by economic factors, simply because in most cases the magnitude of the loads or the lengths of the feeders did not produce sufficient savings to compensate for the costlier higher voltage switchgear. This paper presents some engineering and cost considerations for distribution at 34.5 kV and attempts to show that this voltage level is both economically and technically feasible for large electrical systems.

Niculescu, T.D.; Regan, R.R.

1983-09-01T23:59:59.000Z

412

Theory and practice of dynamic voltage/frequency scaling in the high performance computing environment.  

E-Print Network (OSTI)

?? This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We… (more)

Rountree, Barry Louis

2010-01-01T23:59:59.000Z

413

Definition: Solar cell | Open Energy Information  

Open Energy Info (EERE)

Solar cell Solar cell (Redirected from Definition:PV cell) Jump to: navigation, search Dictionary.png Solar cell Converts light into electrical energy. Traditional solar cells are made from silicon; second-generation solar cells (thin-film solar cells) are made from amorphous silicon or nonsilicon materials such as cadmium telluride; and third-generation solar cells are being made from variety of new materials, including solar inks, solar dyes, and conductive plastics.[1][2] View on Wikipedia Wikipedia Definition A solar cell (also called a photovoltaic cell) is an electrical device that converts the energy of light directly into electricity by the photovoltaic effect. It is a form of photoelectric cell (in that its electrical characteristics-e.g. current, voltage, or resistance-vary

414

Model Predictive Control for Starvation Prevention in a Hybrid Fuel Cell System1  

E-Print Network (OSTI)

voltage, a control system is necessary for maintaining optimal temperature, membrane humidity and pressure: Schematic of the fuel cell stack and air supply control sys- tem. The fuel cell stack consists of 350 cellsModel Predictive Control for Starvation Prevention in a Hybrid Fuel Cell System1 Ardalan Vahidi 2

Stefanopoulou, Anna

415

Variable Voltage Substation Electric Fire and Emergency Response  

Energy.gov (U.S. Department of Energy (DOE))

Variable Voltage Substation Electric Fire and Emergency Response My question is from an emergency response perspective. You stated that it took ~ ½ for electricians to de-energize the electrical components before firefighters were allowed in to fight the fire. This delay causes more damage to equipment and potential propagation of the fire. Is there not a “master” breaker or switch? You’ve brought up a very good point. It gave me a good opportunity to discuss this with our Facilities Department and get a better understanding of the infrastructure upgrade plans. The direct answer to your question is “Yes, but…” Yes, there are “master” breakers and switches, but we can’t control them remotely. SLAC’s AC electrical distribution system at present is manual breakers – we have not installed the infrastructure to remotely control them (except see below). We recently underwent an upgrade to our Master Substation that will allow us to remotely control some high voltage breakers in the future, but we aren’t there yet. We do recognize the value in having this capability (and more importantly, our vulnerability in NOT having it), and have begun the preliminary planning to make this happen. One issue were are working on is cyber security for the power distribution networked infrastructure. Before we install the capability to remotely control the main electrical breakers, we are planning the infrastructure with our Information Technologies organization to ensure we have a robust secure network that is protected from unauthorized access. Once the cyber security issues are addressed and funded, we’re probably 5-10 years out from having remote operation capability due to limited resources to fund and install the infrastructure. Having said the above, we do have the capability of remotely opening the VVS Secondary Main Breakers – the ones that send power to the modulator distribution breakers - from our control room. Those breakers are integral parts of our safety systems in that interlock violation causes the breakers to open and remove power to the klystrons. But everything else is manual only. That remote operation capability would not have helped us in this case, as the VVS Secondary Main Breaker was the one that fried. We needed to open the breaker upstream of the VVS. Thanks for your interest. Let me know if I can provide further information.

416

High Voltage Electrolytes for Li-ion Batteries  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

effective than HFiP in improving cycle life in LNMOgraphite cells at RT. - Synthesized Al(HFiP) additives with electron deficient center Al - Calculated oxidation potential of...

417

Mechanisms of deflagration-to-detonation transition under initiation by high-voltage nanosecond discharges  

SciTech Connect

An experimental study of detonation initiation in a stoichiometric propane-oxygen mixture by a high-voltage nanosecond gas discharge was performed in a detonation tube with a single-cell discharge chamber. The discharge study performed in this geometry showed that three modes of discharge development were realized under the experimental conditions: a spark mode with high-temperature channel formation, a streamer mode with nonuniform gas excitation, and a transient mode. Under spark and transient initiation, simultaneous ignition inside the discharge channel occurred, forming a shock wave and leading to a conventional deflagration-to-detonation transition (DDT) via an adiabatic explosion. The DDT length and time at 1 bar of initial pressure in the square smooth tube with a 20-mm transverse size amounted to 50 mm and 50{mu}s, respectively. The streamer mode of discharge development at an initial pressure of 1 bar resulted in nonuniform mixture excitation and a successful DDT via a gradient mechanism, which was confirmed by high-speed time resolved ICCD imaging. The gradient mechanism implied a longer DDT time of 150{mu}s, a DDT run-up distance of 50 mm, and an initiation energy of 1 J, which is two orders of magnitude less than the direct initiation energy for a planar detonation under these conditions. (author)

Rakitin, Aleksandr E.; Starikovskii, Andrei Yu. [Physics of Nonequilibrium Systems Lab, Moscow Institute of Physics and Technology, 9 Institutski Lane, Dolgoprudny 141700 (Russian Federation)

2008-10-15T23:59:59.000Z

418

A CCD Camera with Electron Decelerator for Intermediate Voltage Electron Microscopy  

SciTech Connect

Electron microscopists are increasingly turning to Intermediate Voltage Electron Microscopes (IVEMs) operating at 300 - 400 kV for a wide range of studies. They are also increasingly taking advantage of slow-scan charge coupled device (CCD) cameras, which have become widely used on electron microscopes. Under some conditions CCDs provide an improvement in data quality over photographic film, as well as the many advantages of direct digital readout. However, CCD performance is seriously degraded on IVEMs compared to the more conventional 100 kV microscopes. In order to increase the efficiency and quality of data recording on IVEMs, we have developed a CCD camera system in which the electrons are decelerated to below 100 kV before impacting the camera, resulting in greatly improved performance in both signal quality and resolution compared to other CCDs used in electron microscopy. These improvements will allow high-quality image and diffraction data to be collected directly with the CCD, enabling improvements in data collection for applications including high-resolution electron crystallography, single-particle reconstruction of protein structures, tomographic studies of cell ultrastructure and remote microscope operation. This approach will enable us to use even larger format CCD chips that are being developed with smaller pixels.

Downing, Kenneth H; Downing, Kenneth H.; Mooney, Paul E.

2008-03-17T23:59:59.000Z

419

An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context  

E-Print Network (OSTI)

An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context Yassine Amirat1,2 , Mohamed Benbouzid2 , Tianzhen Wang3 and Sylvie Turri2 Abstract­Smart grids have become, using the instantaneous power for voltage sags detection in smart grids. Copyright © 2013 Praise Worthy

Brest, Université de

420

Hydroelectric Voltage Generation Based on Water-Filled Single-Walled Carbon Nanotubes  

Science Journals Connector (OSTI)

Hydroelectric Voltage Generation Based on Water-Filled Single-Walled Carbon Nanotubes ... The hydroelectric voltage generator can be expressed by the model illustrated in Figure 6a and b. ... Individual water-filled single-walled carbon nanotubes as hydroelectric power converters ...

Quanzi Yuan; Ya-Pu Zhao

2009-04-21T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Integrating a Feature Selection Algorithm for Classification of Voltage Sags Originated in Transmission and Distribution Networks  

Science Journals Connector (OSTI)

As a global problem in the power quality area, voltage sags are matter of high interest for both utilities and customers. With a view to resolving the problem of sag source location in the power network, this paper introduces a new method based on dimension ... Keywords: Direction, Hybrid Method, Mpca, Voltage Sag

Abbas Khosravi; Toni Martinez; Joaquim Melendez; Joan Colomer; Jorge Sanchez

2007-06-01T23:59:59.000Z

422

A genetic algorithm approach to voltage-VAR control in systems with distributed generation  

Science Journals Connector (OSTI)

This paper presents a case study that highlights the influences which the connection of distributed generation sources may have over the solutions of reactive power compensation and voltage control already existing in a given network. The problem of ... Keywords: distributed generation, genetic algorithms, renewable sources, voltage-var control

Iulia Coroama; Mihai Gavrilas; Ovidiu Ivanov

2010-10-01T23:59:59.000Z

423

A Static Pattern-Independent Technique for Power Grid Voltage Integrity Verification  

E-Print Network (OSTI)

A Static Pattern-Independent Technique for Power Grid Voltage Integrity Verification Dionysios Design verification must include the power grid. Checking that the voltage on the power grid does) the obviously large size of the power grids for modern high-performance chips, and ii) the difficulty of setting

Najm, Farid N.

424

A Static PatternIndependent Technique for Power Grid Voltage Integrity Verification #  

E-Print Network (OSTI)

A Static Pattern­Independent Technique for Power Grid Voltage Integrity Verification # Dionysios Design verification must include the power grid. Checking that the voltage on the power grid does) the obviously large size of the power grids for modern high­performance chips, and ii) the di#culty of setting

Najm, Farid N.

425

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators  

E-Print Network (OSTI)

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators General Description The LM clock timers; multivibrators and high voltage digital logic gates. The LM193 series was designed to directly interface with TTL and CMOS. When operated from both plus and minus power supplies, the LM193

Lanterman, Aaron

426

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions  

E-Print Network (OSTI)

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 19-1 High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 1. DC Properties of Modern Filled Epoxy Insulation Academic and Research Staff Dr. Chathan Cooke Sponsor

427

Creation of Onset Voltage Hash by Anode Spots in a Magnetoplasmadynamic Thruster  

E-Print Network (OSTI)

Creation of Onset Voltage Hash by Anode Spots in a Magnetoplasmadynamic Thruster Luke Uribarri flow rate) of onset voltage fluctuations in a magnetoplasmadynamic thruster operating with three anode materials, and an anode spot model is presented which provides a physical explanation for the properties

Choueiri, Edgar

428

The Onset of Voltage Hash and its Relationship to Anode Spots in Magnetoplasmadynamic Thrusters  

E-Print Network (OSTI)

The Onset of Voltage Hash and its Relationship to Anode Spots in Magnetoplasmadynamic Thrusters, 08544 A phenomenological model is developed to elucidate the relationship between voltage hash and anode electromagnetic force density leads to a mass depletion in the anode region which, in turn, leads to a disparity

Choueiri, Edgar

429

Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power System  

E-Print Network (OSTI)

Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power collapse will occurs in a wind power system is discussed next. The method of power flow calculation is the specific analysis of a given simplified wind power system. Keywords--voltage collapse; Newton

Lavaei, Javad

430

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal Dutta  

E-Print Network (OSTI)

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal}@eecs.umich.edu culler@cs.berkeley.edu Abstract AC power meters require both voltage and current to be sampled physical proximity and fed into a single power metering de- vice. In this paper, we explore the viability

Dutta, Prabal

431

Onset Voltage Hash and Anode Spots in Quasi-Steady Magnetoplasmadynamic  

E-Print Network (OSTI)

Onset Voltage Hash and Anode Spots in Quasi-Steady Magnetoplasmadynamic Thrusters Luke Uribarri: Edgar Y. Choueiri November 2008 #12;ONSET VOLTAGE HASH AND ANODE SPOTS IN QUASI noise ("hash") and anode damage in a self-field, quasi-steady magnetoplasmadynamic thruster (MPDT

Choueiri, Edgar

432

Scaling of Anode Sheath Voltage Fall with the Operational Parameters in Applied-Field MPD  

E-Print Network (OSTI)

Scaling of Anode Sheath Voltage Fall with the Operational Parameters in Applied-Field MPD Thrusters (EPPDyL) Princeton University, Princeton, NJ, 08544, USA Scaling laws for the anode sheath voltage fall in applied-field MPD thrusters are derived in order to better understand the physics behind anode sheath

Choueiri, Edgar

433

Reactive power management of distribution networks with wind generation for improving voltage stability  

E-Print Network (OSTI)

Reactive power management of distribution networks with wind generation for improving voltage February 2013 Available online Keywords: Composite load Distributed generation D-STATCOM Q with distributed wind generation. Firstly, the impact of high wind penetration on the static voltage stability

Pota, Himanshu Roy

434

Voltage Control of Distribution Networks with Distributed Generation using Reactive Power  

E-Print Network (OSTI)

Voltage Control of Distribution Networks with Distributed Generation using Reactive Power. Nasiruzzaman Abstract--Voltage profile of distribution networks with dis- tributed generation are affected significantly due to the integra- tion of distributed generation (DG) on it. This paper presents a way

Pota, Himanshu Roy

435

Direct Power Control of Doubly-Fed Generator Based Wind Turbine Converters to Improve Low Voltage  

E-Print Network (OSTI)

Control (DPC) is discussed for Low Voltage Ride Through (LVRT) of DFIG based wind turbine converters power integration state that doubly fed induction generator (DFIG) controllers should be capable and maintaining dc bus voltage, then the DFIG will stay online during the disturbance. A fast acting controller

Kimball, Jonathan W.

436

Energy Aware Dynamic Voltage and Frequency Selection for Real-Time Systems with Energy Harvesting  

E-Print Network (OSTI)

Energy Aware Dynamic Voltage and Frequency Selection for Real-Time Systems with Energy Harvesting}@binghamton.edu Abstract In this paper, an energy aware dynamic voltage and frequency selection (EA-DVFS) algorithm energy and the harvested energy in a future duration. Specifically, if the system has sufficient energy

Qiu, Qinru

437

The high voltage problem in the saturated core HTS fault current limiter  

Science Journals Connector (OSTI)

A small model of a one-phase saturated core HTS fault current limiter was developed. It consists of an iron core, an AC coil and a DC HTS coil. The HTS coil comprised six 126 turns double-pancakes (ID 70 mm), wound after heat treatment from Bi-2223 multifilamentary tape in Ag matrix. A fault simulation circuit was set up to characterize the dynamic properties of the model limiter. The voltages and currents of the AC coil and the DC HTS coil were measured through a computer-based data acquisition system. The tests have shown that the limiter has a fast response and the first current peak can be easily limited, but a high voltage will be induced on the DC HTS coil side during the fault state. This high voltage can badly affect the DC current equipment on the DC HTS coil side. The origin and value of the high voltage can be explained using a transformer model. For a limiter with n1 turns AC coil and n2 turns DC coil, the largest induced voltage will be roughly close to (n2/n1)U, where U is the rated voltage of the limiter. To commercialize this kind of limiter, the high voltage problem must be solved. Some different designs were introduced to lower the induced voltage.

Y.F. He; J.H. Li; X.H. Zong; J. Sun; Y.N. Wang; C.L. Wu; J.X. Wang

2003-01-01T23:59:59.000Z

438

A theoretical study of the incandescent filament lamp performance under voltage flicker  

SciTech Connect

Incandescent filament lamp flicker, produced by voltage fluctuation, is a power quality problem that caused engineering concern since the onset of electrical illumination technology. The flicker phenomenon was analyzed and explained in early studies. Standards dealing with acceptable flicker levels are well known, nevertheless, today the discussion about flicker continues to be a top priority topic due to the fact that steady-state and transient voltage waveform distortion is a growing problem in low and medium voltage systems. In many situations voltage flicker is caused by subharmonics and interharmonics of voltage. Cycloconverters, welders and arc furnaces, eccentrically operating tools and integral cycle controlled power equipment are notorious for producing voltage flicker. The goal of this paper is to provide solid mathematical basis for the analytical modeling of incandescent filament lamp flicker when the voltage is nonsinusoidal. A mathematical model that enables the evaluation of the luminous flux modulation caused by noninteger harmonics (subharmonics and interharmonics) is presented. Three situations are detailed: square-wave voltage modulation, sinusoidal modulation and the case of noninteger harmonics with nearly contiguous frequencies.

Peretto, L. [Univ. of Bologna (Italy)] [Univ. of Bologna (Italy); Emanuel, A.E. [Worcester Polytechnic Inst., MA (United States)] [Worcester Polytechnic Inst., MA (United States)

1997-01-01T23:59:59.000Z

439

Evaluation of Insulation Systems for the Optimal Design of High Voltage Pulse Transformers  

E-Print Network (OSTI)

This paper presents a study for the design of the insulation systems of high voltage pulse transformer based on experimental tests and numerical simulations. Data of high voltage tests on solid and liquid insulation materials are presented and discussed. The understanding of each part of the insulation is supported by electrostatic fields simulations.

Sylvain, Candolfi; Davide, Aguglia; Philippe, Viarouge; Jürgen, Biela; Jerome, Cros

2015-01-01T23:59:59.000Z

440

DECENTRALIZED VOLTAGE CONTROL TO MINIMIZE DISTRIBUTION LOSSES IN AN ISLANDED MICROGRID  

E-Print Network (OSTI)

power sources and energy storage systems such as batteries requires new power and voltage control-time voltage control algorithm that minimizes power losses for a microgrid supported by inverter based Microgrids can bring electricity power to rural communities or isolated military forward operation bases

Peng, Huei

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

The activated state of a sodium channel voltage sensor in a membrane environment  

Science Journals Connector (OSTI)

...suggests a displacement of ?4 elementary charges per subunit across...voltage sensor reveals a focused electric field . Nature 427 ( 6974...CA Horn R ( 2005 ) Focused electric field across the voltage sensor of potassium...protease activity for protamine resistance of Escherichia coli . Arch...

Sudha Chakrapani; Pornthep Sompornpisut; Pathumwadee Intharathep; Benoît Roux; Eduardo Perozo

2010-01-01T23:59:59.000Z

442

Public Opinions of Building Additional High-Voltage Electric Power Lines  

E-Print Network (OSTI)

to build new power lines. Residents living in counties with planned routes for new transmission linesPublic Opinions of Building Additional High-Voltage Electric Power Lines A Report to the National-Voltage Electric Power Lines: A Report to the National Science Foundation and the Electric Power Research Center

Tesfatsion, Leigh

443

A new technique to reject dc-link voltage ripple in PWM inverters  

E-Print Network (OSTI)

on the rlc-link, is numerically calculated. Let us assume, Inverfer output frequency f, ? 60 Hz Vs, = 1 pu Dc ? link voltage rrpple = k Vs, ? 0. 2 x Vge = . 2 pu Dc ? link voltage ripple frequency f, = 120 Hz :tfodulation index ? 0. 5 Frequency spectrum...

Shireen, Wajiha

1990-01-01T23:59:59.000Z

444

VOLTAGE COLLAPSE AND TRANSIENT ENERGY FUNCTION ANALYSES OF AC/DC SYSTEMS  

E-Print Network (OSTI)

for power system dynamic models, including a third order representation of high voltage direct current (HVDC power limits, HVDC firing angle limits and voltage dependent current order limits (VDCOL) are shown the derivation of individual component Lyapunov functions for simplified models of HVDC links connected

Cañizares, Claudio A.

445

Performance of MicroLink Cells Developed Under Navy STTR: Cooperative Research and Development Final Report, CRADA Number CRD-11-426  

SciTech Connect

Evaluate MicroLink cells as a function of temperature and spectral irradiance following the teams' standard procedures. These measurements will include the standard procedures for evaluating multijunction cells including quantum efficiency measurements and current versus voltage measurements.

Emery, K.

2013-06-01T23:59:59.000Z

446

High voltage power supply with modular series resonant inverters  

DOE Patents (OSTI)

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

Dreifuerst, Gary R. (Livermore, CA); Merritt, Bernard T. (Livermore, CA)

1995-01-01T23:59:59.000Z

447

High voltage power supply with modular series resonant inverters  

DOE Patents (OSTI)

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.

Dreifuerst, G.R.; Merritt, B.T.

1995-07-18T23:59:59.000Z

448

Characterization of Voltage Fade in Lithium-ion Cells with Layered...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0.375 Mn 0.375 Co 0.25 O 0.2 Cathode Materials Link: http:www.sciencedirect.comsciencearticlepiiS0378775313016881 4. D. Mohanty, A. Huq, E.A. Payzant, A.S. Sefat, J....

449

High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report | Open  

Open Energy Info (EERE)

High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report Jump to: navigation, search Tool Summary LAUNCH TOOL Name: High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report Focus Area: Crosscutting Topics: Policy Impacts Website: www.netl.doe.gov/smartgrid/referenceshelf/reports/HV-BPL_Final_Report. Equivalent URI: cleanenergysolutions.org/content/high-voltage-broadband-over-powerline Language: English Policies: "Deployment Programs,Financial Incentives" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Technical Assistance This reports details findings from a pilot High Voltage Broadband over Power Line (HV-BPL) program, an effort to develop a disruptive technology

450

Application of evolutionary algorithms for the planning of urban distribution networks of medium voltage  

E-Print Network (OSTI)

Abstract—Currently, an important issue in power distribution is the need to optimize medium voltage (mv) networks serving urban areas. This paper shows how an evolutionary algorithm can be used as the basis for the type of efficient algorithm such optimization demands. The search for optimal network solution will be restricted to a graph defined from the urban map, so each graph branch represents a trench. The solution space (networks) is assumed with “loop feeder circuits”: networks with two electrical paths from the high voltage/medium voltage (hv/mv) substations to the customers. In the optimization process, the investment and loss load costs are considered taking into account the constraints of conductor capacities and voltage drop. The investment costs will take into account that some cables can be lying in the same trench. The process was applied for a Spanish city of 200 000 inhabitants. Index Terms—Evolutionary algorithm, medium voltage network planning, network design, urban distribution network. I.

unknown authors

2002-01-01T23:59:59.000Z

451

Determination of the inductance of imploding wire array Z-pinches using measurements of load voltage  

SciTech Connect

The inductance of imploding cylindrical wire array z-pinches has been determined from measurements of load voltage and current. A thorough analysis method is presented that explains how the load voltage of interest is found from raw signals obtained using a resistive voltage divider. This method is applied to voltage data obtained during z-pinch experiments carried out on the MAGPIE facility (1.4 MA, 240 ns rise-time) in order to calculate the load inductance and thereafter the radial trajectory of the effective current sheath during the snowplough implosion. Voltage and current are monitored very close to the load, allowing these calculations to be carried out without the need for circuit modelling. Measurements give a convergence ratio for the current of between 3.1 and 5.7 at stagnation of the pinch.

Burdiak, G. C.; Lebedev, S. V.; Hall, G. N.; Harvey-Thompson, A. J.; Suzuki-Vidal, F.; Swadling, G. F.; Khoory, E.; Pickworth, L.; Bland, S. N.; Grouchy, P. de; Skidmore, J. [Blackett Laboratory, Imperial College, London SW7 2BW (United Kingdom)

2013-03-15T23:59:59.000Z

452

Definition: Solar cell | Open Energy Information  

Open Energy Info (EERE)

cell cell Jump to: navigation, search Dictionary.png Solar cell Converts light into electrical energy. Traditional solar cells are made from silicon; second-generation solar cells (thin-film solar cells) are made from amorphous silicon or nonsilicon materials such as cadmium telluride; and third-generation solar cells are being made from variety of new materials, including solar inks, solar dyes, and conductive plastics.[1][2] View on Wikipedia Wikipedia Definition A solar cell (also called a photovoltaic cell) is an electrical device that converts the energy of light directly into electricity by the photovoltaic effect. It is a form of photoelectric cell (in that its electrical characteristics-e.g. current, voltage, or resistance-vary when light is incident upon it) which, when exposed to light, can generate

453

Electrochemical sensor for monitoring electrochemical potentials of fuel cell components  

DOE Patents (OSTI)

An electrochemical sensor comprised of wires, a sheath, and a conduit can be utilized to monitor fuel cell component electric potentials during fuel cell shut down or steady state. The electrochemical sensor contacts an electrolyte reservoir plate such that the conduit wicks electrolyte through capillary action to the wires to provide water necessary for the electrolysis reaction which occurs thereon. A voltage is applied across the wires of the electrochemical sensor until hydrogen evolution occurs at the surface of one of the wires, thereby forming a hydrogen reference electrode. The voltage of the fuel cell component is then determined with relation to the hydrogen reference electrode.

Kunz, Harold R. (Vernon, CT); Breault, Richard D. (Coventry, CT)

1993-01-01T23:59:59.000Z

454

Effect of liquid dielectrics on the efficiency of silicon solar cells  

Science Journals Connector (OSTI)

The results of experimental studies of the change in the photoelectric characteristics of silicon solar cells produced as a result of depositing ... open-circuit voltage, and significantly increases the efficiency

Yu. A. Abramyan; G. G. Karamyan; A. A. Murodyan; V. I. Stafeev…

1999-12-01T23:59:59.000Z

455

Responses from freshwater sediment during electricity generation using microbial fuel cells  

Science Journals Connector (OSTI)

The actual potential of a fuel cell falls below its equilibrium potential due...30...]. To compare the performances of the sediment batteries, polarization and power curves were drawn for...3.... The voltage at e...

Seok Won Hong; In Seop Chang; Yong Su Choi…

2009-04-01T23:59:59.000Z

456

High Energy Density Li-ion Cells for EVs Based on Novel, High...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Storage Systems Vehicle Technologies Annual Merit Review 6182014 1 High Energy Density Li-ion Cells for EV's Based on Novel, High Voltage Cathode Material Systems Keith D. Kepler...

457

A novel voltage and frequency controller for standalone DFIG based Wind Energy Conversion System  

Science Journals Connector (OSTI)

Abstract This paper presents a new speed-sensorless control strategy for a stand-alone doubly-fed induction generator supplying energy to an isolated load. The method is based on the root mean square (rms) detection scheme. The generated stator voltage is controlled via rotor currents. Amplitude of stator voltage and its frequency are controlled simultaneously. The output signals from the voltage controllers are the reference signals for the rotor current amplitude and frequency of the stator voltage is regulated with the help of frequency control loop. This developed direct voltage control method is applicable for both the balanced and unbalanced load and also for standalone and grid connected mode. The control pulses for the rotor side converter is supplied by the hysteresis controller which is operated on the error signal calculated between actual and reference rotor currents. This paper also provides the brief idea about the voltage and frequency control on modern Autonomous DFIG based Wind Energy Systems via single phase mathematical model of standalone DFIG system. A short state-of-the-art review on mechanical position/speed sensorless control schemes for autonomous DFIG based \\{WESs\\} is presented, which helps the present researcher and students working in this area. These include stator flux oriented control techniques; direct voltage control techniques; MARS observer based techniques for autonomous DFIG-based variable-speed WESs. Simulation results obtained from a 2MVA DFIG system, prototype in MATLab/Simulink, are presented and discussed in this paper.

Rishabh Dev Shukla; Ramesh Kumar Tripathi

2014-01-01T23:59:59.000Z

458

An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.  

SciTech Connect

References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

Litzenberger, Wayne; Lava, Val

1994-08-01T23:59:59.000Z

459

CRADA Final Report: Process development for hybrid solar cells  

SciTech Connect

TCF funding of a CRADA between LBNL and RSLE leveraged RSLE's original $1M investment in LBNL research and led to development of a solar cell fabrication process that will bring the high efficiency, high voltage hybrid tandem solar cell closer to commercialization. RSLE has already built a pilot line at its Phoenix, Arizona site.

Ager, Joel W

2011-02-14T23:59:59.000Z

460

Macroporous n-GaP in Nonaqueous Regenerative Photoelectrochemical Cells  

Science Journals Connector (OSTI)

Michelle J. Price and Stephen Maldonado * ... Photoelectrochemical cells are attractive systems for the generation of energy-rich chemical fuels. ... (1-4) Generally, larger operating cell voltages than those obtained with commercial silicon (Si) photovoltaics under solar illumination at 1.5 air mass units (AMU) are needed to drive kinetically slow, multielectron charge-transfer reactions involved in fuel production. ...

Michelle J. Price; Stephen Maldonado

2009-06-22T23:59:59.000Z

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Low Voltage Operational Amplifier Design for Energy Harvesting Applications  

E-Print Network (OSTI)

Wireless and embedded systems in remote locations are commonly powered using batteries due to the difficulty of providing a tethered energy infrastructure. However, replacing batteries in these sensors: Background Power Management System Figure 1. A sediment microbial fuel cell (SMFC) with microbial anode

Collins, Gary S.

462

Princeton Power Systems (TRL 5 6 Component)- Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Energy.gov (U.S. Department of Energy (DOE))

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

463

Source of Sustained Voltage Difference between the Xylem of a Potted Ficus benjamina Tree and Its Soil  

E-Print Network (OSTI)

It has long been known that there is a sustained electrical potential (voltage) difference between the xylem of many plants

Mershin, Andreas

464

High Power, High Voltage FETs in Linear Applications: A User's Perspective  

SciTech Connect

The specifications of the current crop of highpower, high-voltage field-effect transistors (FETs) can lure a designer into employing them in high-voltage DC equipment. Devices with extremely low on-resistance and very high power ratings are available from several manufacturers. However, our experience shows that high-voltage, linear operation of these devices at near-continuous duty can present difficult reliability challenges at stress levels well-below their published specifications. This paper chronicles the design evolution of a 600 volt, 8 ampere shunt regulator for use with megawatt-class radio transmitters, and presents a final design that has met its reliability criteria.

N. Greenough, E. Fredd, S. DePasquale

2009-09-21T23:59:59.000Z

465

Monitoring voltage collapse margin with synchrophasors across transmission corridors with multiple lines and multiple contingencies  

E-Print Network (OSTI)

We use synchrophasor measurements of the complex voltage and current at both ends of multiple transmission lines that connect areas of a power system to monitor the online voltage collapse margin. A new reduction is used to reduce the multiple transmission lines to a single line equivalent and determine how to combine the synchrophasor measurements. Generator reactive power limits can be accommodated. The results show that this methodology can capture the effect of multiple contingencies inside the transmission corridors, giving awareness to the operators about the severity of contingencies with respect to voltage stability.

Ramirez, Lina

2014-01-01T23:59:59.000Z

466

In hippocampal CA1 pyramidal cells and in cerebellar Purkinje cells, transient depolarization by brief trains of  

E-Print Network (OSTI)

In hippocampal CA1 pyramidal cells and in cerebellar Purkinje cells, transient depolarization. This phenomenon, known as depolarization-induced suppression of inhibition (DSI), depends upon Ca2+ influx through voltage-activated Ca2+ channels (Lenz et al. 1998) and appears to involve the production of a retrograde

Zucker, Robert S.

467

The effect of inspection error on quality and producer losses: the case of nominal-the-best type quality characteristic and rework  

Science Journals Connector (OSTI)

In this study, the effect of inspection error (IE) on quality and producer losses is investigated for a nominal-the-best type quality characteristic determined by a manufacturing process centre with a separate rework unit. The probability distribution and the first two moments of the resulting quality characteristic values are derived and used together with Markov chain models and simulation to study the quality and producer losses and the related statistics for various processes and gauge capability levels. The results of this study confirm with strong theoretical and empirical evidence that an effective way of achieving robustness to IE is to improve the process capability. This study provides benchmarks that support understanding and decision making of quality professionals. [Received 11 November 2010; Revised 3 June 2011; Revised 6 December 2011; Accepted 18 December 2011

Gülser Köksal; Aysun Ta?eli; Leman Esra Dolgun; ?nci Batmaz

2013-01-01T23:59:59.000Z

468

A SCR SWITCHED CAPACITOR VOLTAGE REGULATOR FOR 150 kV NEUTRAL BEAM POWER SUPPLY  

E-Print Network (OSTI)

2 ;;o c: REGULATOR BANK SCR TRIGGER CHASSIS BLOCK DIAGRAMLBL-8156 UC-20 A SCR SWITCHED CAPACITOR VOLTAGE REGULATORwill discharge through the SCR and the diodes. All of the

Milnes, K.A.

2011-01-01T23:59:59.000Z

469

Backstepping DC Voltage Control in a Multi-terminal HVDC System Connecting Offshore Wind Farms  

Science Journals Connector (OSTI)

Wind power is projected to play an important ... current and future power systems. To integrate offshore wind farms to the existing onshore grid, voltage source ... in a safe range. To distribute transmitted wind

Xiaodong Zhao; Kang Li; Yusheng Xue

2014-01-01T23:59:59.000Z

470

Generalized charge simulation method for the calculation of the electric field in high voltage substations  

Science Journals Connector (OSTI)

This paper deals with the calculation of the electric field strength in high voltage (HV) substations comprising complex geometrical structures. Generalized charge simulation ... is to examine the influence of to...

Aleksandar Rankovi?; Milan S. Savi?

2010-07-01T23:59:59.000Z

471

Research on Low-Voltage Early Warning System of Coalmine Power Grid  

Science Journals Connector (OSTI)

Research is proposed on coalmine power grid safety-running in case to insure coalmine ... voltage problem now still lying in the coalmine power grid, a method combined fuzzy comprehensive evaluation with gray com...

Tieying Zhao; Na Wang

2012-01-01T23:59:59.000Z

472

Scaling Analysis of On-Chip Power Grid Voltage Variations in Nanometer Scale ULSI  

Science Journals Connector (OSTI)

This paper presents a detailed scaling analysis of the power supply distribution network voltage drop in DSM technologies. The effects of chip temperature, electromigration and interconnect technology scaling (in...

Amir H. Ajami; Kaustav Banerjee…

2005-03-01T23:59:59.000Z

473

Voltage Sag-Related Upsets of Industrial Process Controls in Petroleum and Chemical Industries  

E-Print Network (OSTI)

with PLC controls. The sensitivity of these process controls can stop an essential service motor required for a continuous process such as in a refinery or chemical plant. Typically the controls are sensitive to the common momentary voltage sag caused...

Mansoor, A.; Key, T.; Woinsky, S.

474

Insulation co-ordination for continuous operating voltages and temporary overvoltages  

Science Journals Connector (OSTI)

This paper presents an approach to the insulation co-ordination of electric-power installations in ... calculate the necessary required withstand voltages of unit insulations for short-duration (1 min) power-...

Zlatoje Zdravkovi?; Petar Vukelja; Jovan Mrvi?

2006-06-01T23:59:59.000Z

475

Optical High Voltage Sensor with Oil- and Gas-free Insulation  

Science Journals Connector (OSTI)

We present an electro-optic high voltage sensor with novel oil- and gas-free insulation based on capacitive electric field steering. The sensor's accuracy is within ±0.2% in a...

Marchese, Sergio V; Wildermuth, Stephan; Steiger, Olivier; Pascal, Joris; Bohnert, Klaus; Eriksson, Göran; Czyzewski, Jan

476

Algorithms for Combined Inter- and Intra-Task Dynamic Voltage Scaling  

Science Journals Connector (OSTI)

......CDVS well by fully exploiting the benefit of voltage scaling and processor's...No. 2011- 0029805), under the Smart IT Convergence System Research Center...Cognitive Packet Network. Int. Conf. Smart Grids Green Communications and IT Energy-aware......

Hyungjung Seo; Jaewon Seo; Taewhan Kim

2012-11-01T23:59:59.000Z

477

Analysis of asset health : an approach to monitoring and diagnostics for medium voltage circuit breakers  

E-Print Network (OSTI)

The Medium Voltage Electric Industry is a very conservative and risk adverse sector that has undergone very little change in the past 30 years when compared to other technologically dependent activities; this reality is ...

Corona, Erick (Erick Gustavo)

2013-01-01T23:59:59.000Z

478

Design of the Wireless Temperature Measurement Alarming System in the High-Voltage Transformer Substation  

Science Journals Connector (OSTI)

Due to electric power overload and equipment aging, fire and explosion occur at transmission circuitry joints in high-voltage transformer substation caused by high temperatures accumulated at these...

Qiang Gao; Hongli Wang; Huaxiang Wang

2008-01-01T23:59:59.000Z

479

Fuzzy Control on Voltage/Reactive Power in Electric Power Substation  

Science Journals Connector (OSTI)

A fuzzy method using in voltage and reactive power control in electric substation is proposed based on the improved 17 ... times at the tap positions of transformers in substation are much less than usual. So,...

Xiu-hua Wu; Jun-cheng Wang; Ping Yang…

2009-01-01T23:59:59.000Z

480

A multilevel energy buffer and voltage modulator for grid-interfaced micro-inverters  

E-Print Network (OSTI)

Micro-inverters operating into the single-phase grid from solar photovoltaic (PV) panels or other low-voltage sources must buffer the twice-line-frequency variations between the energy sourced by the PV panel and that ...

Chen, Minjie

Note: This page contains sample records for the topic "nominal cell voltage" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

STATCOM-based voltage and frequency regulator for stand-alone asynchronous generator  

Science Journals Connector (OSTI)

This paper presents a STATCOM-based voltage and frequency regulation for stand-alone asynchronous generator feeding linear and nonlinear loads. The SEIG have inherent poor voltage and frequency regulation. The voltage and frequency depend upon the load current and power factor of the load with fixed excitation capacitor employing unregulated turbines. The changing consumer load requires variable reactive power compensation for excitation requirement. Consumer load contains harmonics and performance of SEIG is largely affected by these load harmonics. A current controlled voltage source inverter working as STATCOM is used for harmonic elimination, load balancing and variable reactive power compensation. A DC chopper with dump load is connected across DC bus capacitor to regulate varying consumer load. The control algorithm has been first co-simulated with processor in the loop (PIL) and then experimentally validated. The transient behaviour of developed prototype system for application and removal of balanced, unbalanced, nonlinear load is investigated.

Dheeraj Kumar Palwalia

2014-01-01T23:59:59.000Z

482

The current-voltage characteristic of a hot-cathode electric arc at low pressures  

Science Journals Connector (OSTI)

It has been shown that in a hot-cathode electric arc operating at low pressures of the working ... drop arises that results in an increase in discharge voltage with current even before the transition of the discharge

C. P. Nikulin

2011-03-01T23:59:59.000Z

483

Nonlinear DSTATCOM controller design for distribution network with distributed generation to enhance voltage stability  

E-Print Network (OSTI)

Nonlinear DSTATCOM controller design for distribution network with distributed generation Accepted 19 June 2013 Keywords: Distributed generation Distribution network DSATACOM Partial feedback connected to a distribution network with distributed generation (DG) to regulate the line voltage

Pota, Himanshu Roy

484

Comparison of resonant current regulators for DFIG during grid voltage distortion  

Science Journals Connector (OSTI)

We investigate two different kinds of resonant current regulators for a doubly fed induction generator (DFIG) under distorted grid voltage conditions: proportional ... part. Based on the mathematical model of DFIG

Yi-peng Song; Heng Nian

2013-12-01T23:59:59.000Z

485

Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions  

Science Journals Connector (OSTI)

This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the po...

Jia-bing Hu; Yi-kang He; Lie Xu

2008-12-01T23:59:59.000Z

486

In Vivo Voltage-Sensitive Dye Optical Functional Imaging of the Subcortical Brain  

Science Journals Connector (OSTI)

We combined voltage-sensitive dye imaging (VSDi) with gradient-index (GRIN) rod lens to study neural functions in mice vibrissae system. Neural activities evoked in the thalamic...

Tang, Qinggong; Tsytsarev, Vassiliy; Liang, Chia-Pin; Erzurumlu, Reha; Chen, Yu

487

Electrical aging of stator insulation of low voltage rotating machines supplied by inverters  

SciTech Connect

Nowadays, use of inverters for speed variation of low voltage motors becomes more and more usual. The most common technology for this kind of apparatus uses the Pulse Width Modulation (PWM). It is characterized by a square voltage shape with short rise and fall times. In order to insure the quality of turn to ground insulation submitted to these constraints, a study on the aging of Polyethylene terephthalate (Mylar{trademark}) has been undertaken. Influence of rise and fall times, frequency and voltage magnitude has been investigated for time duration up to 1,000 hours. To realize a good voltage application, samples were previously metalized. Two different behaviors according to the rise time and magnitude are observed. For long rise and fall times, changes in the capacity values are obtained although, for smaller rise or fall times, a degradation of the metalized electrode appears. A surface charge generation process is discussed to explain this phenomena.

Bellomo, J.P.; Lebey, T. [Lab. Genie Electrique de Toulouse (France); Oraison, J.M.; Peltier, F. [Leroy-Somer, Angouleme (France)

1996-12-31T23:59:59.000Z

488

Harmonic control of multiple-stator induction machines for voltage regulation  

E-Print Network (OSTI)

Small, one to a few horsepower, three-phase induction machines with three sets of electrically-isolated, magnetically-coupled stator winding circuits are described. A voltage inverter is developed and used to drive one set ...

Holloway, Jack Wade, 1980-

2004-01-01T23:59:59.000Z

489

Low-voltage, low-power circuits for data communication systems  

E-Print Network (OSTI)

There are growing industrial demands for low-voltage supply and low-power consumption circuits and systems. This is especially true for very high integration level and very large scale integrated (VLSI) mixed-signal chips and system...

Chen, Mingdeng

2005-02-17T23:59:59.000Z

490

Current mode integrators and their applications in low-voltage high frequency CMOS signal processing  

E-Print Network (OSTI)

Low voltage CMOS fully differential integrators for high frequency continuous-time filters using current-mode techniques are presented.. Current mode techniques are employed to avoid the use of the floating differential pair, in order to achieve...

Smith, Sterling Lane

2012-06-07T23:59:59.000Z

491

Electron Energy Analysis of Vacuum Discharge in High-Voltage Accelerator Tube  

Science Journals Connector (OSTI)

......measurement of the electron energy spectrum during discharge adds some new knowledge to the total voltage...authors sincerely thank Electron Energy Analysis of Vacuum Discharge...Physics, Academic Press, New York, Vol. 6, p. 297. 25......

Akio TAKAOKA; Katsumi URA; Kiyokazu YOSHIDA

1982-01-01T23:59:59.000Z

492

Arc voltage distribution skewness as an indicator of electrode gap during vacuum arc remelting  

DOE Patents (OSTI)

The electrode gap of a VAR is monitored by determining the skewness of a distribution of gap voltage measurements. A decrease in skewness indicates an increase in gap and may be used to control the gap. 4 figs.

Williamson, R.L.; Zanner, F.J.; Grose, S.M.

1998-01-13T23:59:59.000Z

493

Analysis of three-phase rectifiers with constant-voltage loads  

E-Print Network (OSTI)

This work presents a quantitative analysis of the operating characteristics of three-phase diode bridge rectifiers with AC-side reactance and constant-voltage loads. We focus on the case where the AC-side currents vary ...

Caliskan, Vahe

494

High-voltage pulsed discharge in an electron source with a plasma cathode  

Science Journals Connector (OSTI)

The nature of and mechanism for producing a high-voltage discharge in an electron source with a plasma cathode are investigated. The possibility of generating pulsed electron currents with an amplitude of 103–104

S. P. Bugaev; F. Ya. Zagulov

1973-10-01T23:59:59.000Z

495

On the Simulation of NBTI-Induced Performance Degradation Considering Arbitrary Temperature and Voltage Variations  

Science Journals Connector (OSTI)

With aggressive CMOS technology scaling, Negative Bias Temperature Instability (NBTI) has emerged as one of the major system lifetime reliability threats, which gradually increases PMOS transistor threshold voltage and hence results in increased circuit ...

Ting Wang, Qiang Xu

2014-06-01T23:59:59.000Z

496

Manufacturing challenges of optical current and voltage sensors for utility applications  

SciTech Connect

Measurement of voltages and currents in power transmission and distribution systems are critical to the electric utility industry for both revenue metering and reliability. Nonconventional instrument transformers based on intensity modulation of optical signals have been reported in the literature for more than 20 years. Recently described devices using passive bulk optical sensor elements include the Electro-Optic Voltage Transducer (EOVT) and Magneto-Optic Current Transducer (MOCT). These technologies offer substantial advantages over conventional instrument transformers in accuracy, optical isolation bandwidth, environmental compatibility, weight and size. This paper describes design and manufacturing issues associated with the EOVT and the Optical Metering Unit (OMU) recently introduced by ABB with field installation results presented for prototype units in the 345 kV and 420 kV voltage classes. The OMU incorporates an EOVT and MOCT to monitor the voltage and current on power transmission lines using a single free-standing device.

Yakymyshyn, C.P. [Montana State Univ., Bozeman, MT (United States). Dept. of Electrical and Computer Engineering; Brubaker, M.A. [Los Alamos National Lab., NM (United States); Johnston, P.M. [Johnston (Paul M.), Raleigh, NC (United States); Reinbold, C. [ABB High Voltage Switchgear, Greensburg, PA (United States)

1997-12-01T23:59:59.000Z

497

Electrochemical characterization of Polymer Electrolyte Membrane Water Electrolysis Cells  

Science Journals Connector (OSTI)

Abstract The purpose of this paper is to report on the electrochemical characterization of Polymer Electrolyte Membrane (PEM) water electrolysis cells. Results were obtained using membrane-electrode assemblies containing unsupported IrO2 catalyst at anode for the oxygen evolution reaction (OER) and carbon-supported platinum nano-particles at the cathode for the hydrogen evolution reaction (HER). Roughness factors of anodes and cathodes have been determined using an internal reference electrode. Individual cell voltage contributions have also been measured as a function of operating current density. Cell impedance spectra have been measured at different cell voltages along the polarization curve. It is shown that charge transfer processes are major cell impedance contributors at voltages up to 1.8-1.9 V. At higher cell voltages, cell impedances are mainly resistive. It is shown that the impedance associated with the HER is negligible and that the two time-constants observed on experimental impedance spectra can both be attributed to the OER. Possible mechanism options are discussed. Finally, some results related to the EIS characterization of PEM water electrolysis stacks are also reported.

C. Rozain; P. Millet

2014-01-01T23:59:59.000Z

498

Novel passive lossless turn-on snubber for voltage source inverters  

SciTech Connect

A novel passive lossless turn-on snubber with a soft clamped turn-off snubber circuit for voltage source inverters is proposed. The energy trapped in the snubber is recovered into the dc supply and load without any active devices, associated control circuitry, or resistors. The overshoot voltage on the switches is clamped, and the peak switch current is low, making this snubber suitable for use in high-power insulated gate bipolar transistor (IGBT) inverters.

He, X.; Qian, Z.M. [Zhejiang Univ., Hangzhou (China). Dept. of Electrical Engineering; Finney, S.J.; Williams, B.W. [Heriot-Watt Univ., Edinburgh (United Kingdom). Dept. of Computing and Electrical Engineering

1997-01-01T23:59:59.000Z

499

Hybrid integrated active antennas, voltage-controlled oscillators and switchable & tunable CPW-slotline filters  

E-Print Network (OSTI)

HYBRID INTEGRATED ACTIVE ANTENNAS, VOLTAGE-CONTROLLED OSCILLATORS AND SWITCHABLE & TUNABLE CPW-SLOTLINE FILTERS A Thesis by JULIO ANGEL NAVARRO Submitted to the Office of Graduate Studies of Texas ARM University in partial fulfillment... of the requirements for the degree of MASTER OF SCIENCE December 1990 Major Subject: Electrical Engineering HYBRID INTEGRATED ACTIVE ANTENNAS, VOLTAGE-CONTROLLED OSCILLATORS AND SWITCHABLE 2 TUNABLE CPW-SLOTLINE FILTERS A Thesis by JULIO ANGEL NAVARRO...

Navarro, Julio A

1990-01-01T23:59:59.000Z

500

Cermet insert high voltage holdoff improvement for ceramic/metal vacuum devices  

DOE Patents (OSTI)

An improved metal-to-ceramic seal is provided wherein the ceramic body of the seal contains an integral region of cermet material in electrical contact with the metallic member, e.g., an electrode, of the seal. The seal is useful in high voltage vacuum devices, e.g., vacuum switches, and increases the high-voltage holdoff capabilities of such devices. A method of fabricating such seals is also provided.

Ierna, W.F.

1986-03-11T23:59:59.000Z