National Library of Energy BETA

Sample records for nameplate capacity mw

  1. Property:Technology Nameplate Capacity (MW) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource HistoryPotentialRuralUtilityScalePVGeneration Jump to:SpatialResolution Jump to:

  2. Property:Device Nameplate Capacity (MW) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to: navigation, search Property NameDefinition Jump to:Property

  3. Property:Installed Capacity (MW) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo,AltFuelVehicle2 Jump to: navigation, searchContDiv JumpTechDsc Jump to:cons JumpCapacity

  4. br Owner br Facility br Type br Capacity br MW br Commercial...

    Open Energy Info (EERE)

    Geothermal Area Northwest Basin and Range Geothermal Region Bruchsal GEPP Municipality Germany Binary Cycle Power Plant MW Bruchsal Geothermal Area Upper Rhine Valley CE Turbo...

  5. Debt extension on small project yields real savings

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    70 MW Idaho Falls Bulb Turbine Project, nameplate capacity 27 MW DworshakClearwater Small Hydro Power, nameplate capacity 5.4 MW Rocky Brook of Mason PUD No. 1, nameplate...

  6. Presentation 2.8: Program for the conversion of Russian municipal boilers with 20MW maximum capacity to biofuel due to funds from the emissions reduction units sell, under the Kyoto Protocol

    E-Print Network [OSTI]

    conversion to wood chips Due to funds from the emissions reduction units sell, under the Kyoto ProtocolPresentation 2.8: Program for the conversion of Russian municipal boilers with 20MW maximum capacity to biofuel due to funds from the emissions reduction units sell, under the Kyoto Protocol Andrey

  7. MHK Projects/Georgetown Bend | Open Energy Information

    Open Energy Info (EERE)

    33.5735, -91.1986 Project Phase Phase 1 Project Installed Capacity (MW) 0 PermitLicense Buildout (MW) 117 Device Nameplate Capacity (MW) 40 kW Number of Devices Deployed 0...

  8. EA-1611: Final Environmental Assessment | Department of Energy

    Office of Environmental Management (EM)

    The proposed Project would include sixty (60) General Electric (GE) 1.5 megawatt (MW) SLE wind turbines with a total Project output nameplate capacity of ninety (90) MW of...

  9. Table 11.6 Installed Nameplate Capacity of Fossil-Fuel Steam-Electric Generators With Environmental Equipment, 1985-2010 (Megawatts)

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page| Open Energy Informationmonthly gasoline price toStocks 2009CubicAnalysisYear Jan

  10. Abatement of Air Pollution: Control of Sulfur Dioxide Emissions...

    Broader source: Energy.gov (indexed) [DOE]

    apply to fossil-fuel fired stationary sources which serve a generator with a nameplate capacity of 15 MW or more, or fossil-fuel fired boilers or indirect heat exchangers with a...

  11. Abatement of Air Pollution: Control of Sulfur Dioxide Emissions from Power Plants and Other Large Stationary Sources of Air Pollution (Connecticut)

    Broader source: Energy.gov [DOE]

    These regulations apply to fossil-fuel fired stationary sources which serve a generator with a nameplate capacity of 15 MW or more, or fossil-fuel fired boilers or indirect heat exchangers with a...

  12. Initial operating experience of the 12-MW La Ola photovoltaic system.

    SciTech Connect (OSTI)

    Ellis, Abraham; Lenox, Carl (SunPower Corporation, Richmond, CA); Johnson, Jay; Quiroz, Jimmy Edward; Schenkman, Benjamin L.

    2011-10-01

    The 1.2-MW La Ola photovoltaic (PV) power plant in Lanai, Hawaii, has been in operation since December 2009. The host system is a small island microgrid with peak load of 5 MW. Simulations conducted as part of the interconnection study concluded that unmitigated PV output ramps had the potential to negatively affect system frequency. Based on that study, the PV system was initially allowed to operate with output power limited to 50% of nameplate to reduce the potential for frequency instability due to PV variability. Based on the analysis of historical voltage, frequency, and power output data at 50% output level, the PV system has not significantly affected grid performance. However, it should be noted that the impact of PV variability on active and reactive power output of the nearby diesel generators was not evaluated. In summer 2011, an energy storage system was installed to counteract high ramp rates and allow the PV system to operate at rated output. The energy storage system was not fully operational at the time this report was written; therefore, analysis results do not address system performance with the battery system in place.

  13. Table 2. Ten Largest Plants by Generation Capacity, 2013

    U.S. Energy Information Administration (EIA) Indexed Site

    Oklahoma" ,"Plant","Primary energy source","Operating company","Net summer capacity (MW)" 1,"Northeastern","Coal","Public Service Co of Oklahoma",1815 2,"Redbud Power...

  14. Table 2. Ten Largest Plants by Generation Capacity, 2013

    U.S. Energy Information Administration (EIA) Indexed Site

    Virginia" ,"Plant","Primary energy source","Operating company","Net summer capacity (MW)" 1,"Bath County","Pumped storage","Virginia Electric & Power Co",3003 2,"North...

  15. Property:Project Installed Capacity (MW) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource HistoryPotentialRuralUtilityScalePVGeneration Jump to: navigation,Power Transfer MethodCity Jump

  16. bectso-10mw | netl.doe.gov

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    PDF-342KB Airpol, Inc., West Paducah, KY PROGRAM PUBLICATIONS Final Reports Clean Coal Technology III: 10-MW Demonstration of Gas Suspension Absorption, Final Project...

  17. ISIS~1985 0.16MW SNS~2006 1.4MW

    E-Print Network [OSTI]

    Katsumoto, Shingo

    m #12;3 J-PARC JSNS ILL ~1974 ISIS~1985 0.16MW SNS~2006 1.4MW JSNS~2008 1MW J-PARC BSNS #12;4 MLF-PARC 180 J-PARC/MLF #12;19 J-PARC #12;20 J-PARC J-PARC K GSI ISIS SNS FNAL CERN GSI J

  18. Offshore Wind Energy Market Installed Capacity is Anticipated...

    Open Energy Info (EERE)

    Offshore Wind Energy Market Installed Capacity is Anticipated to Reach 52,120.9 MW by 2022 Home > Groups > Renewable Energy RFPs Wayne31jan's picture Submitted by Wayne31jan(150)...

  19. Table 2. Ten largest plants by generation capacity, 2013

    U.S. Energy Information Administration (EIA) Indexed Site

    District of Columbia" ,"Plant","Primary energy source","Operating company","Net summer capacity (MW)" 1,"US GSA Heating and Transmission","Natural gas","US GSA Heating and...

  20. Table 2. Ten Largest Plants by Generation Capacity, 2013

    U.S. Energy Information Administration (EIA) Indexed Site

    Vermont" ,"Plant","Primary energy source","Operating company","Net summer capacity (MW)" 1,"Vermont Yankee","Nuclear","Entergy Nuclear Vermont Yankee",619.4 2,"Kingdom Community...

  1. Table 2. Ten Largest Plants by Generation Capacity, 2013

    U.S. Energy Information Administration (EIA) Indexed Site

    California" ,"Plant","Primary energy source","Operating company","Net summer capacity (MW)" 1,"Dynegy Moss Landing Power Plant","Natural gas","Dynegy -Moss Landing LLC",2529...

  2. Biomass Power Generation Market Capacity is Estimated to Reach...

    Open Energy Info (EERE)

    Biomass Power Generation Market Capacity is Estimated to Reach 122,331.6 MW by 2022 Home > Groups > Renewable Energy RFPs Wayne31jan's picture Submitted by Wayne31jan(150)...

  3. Microwave (MW) and Radio Frequency (RF) as Enabling Technologies...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Microwave (MW) and Radio Frequency (RF) as Enabling Technologies for Advanced Manufacturing Microwave (MW) and Radio Frequency (RF) as Enabling Technologies for Advanced...

  4. Economic Development Impact of 1,000 MW of Wind Energy in Texas

    SciTech Connect (OSTI)

    Reategui, S.; Hendrickson, S.

    2011-08-01

    Texas has approximately 9,727 MW of wind energy capacity installed, making it a global leader in installed wind energy. As a result of the significant investment the wind industry has brought to Texas, it is important to better understand the economic development impacts of wind energy in Texas. This report analyzes the jobs and economic impacts of 1,000 MW of wind power generation in the state. The impacts highlighted in this report can be used in policy and planning decisions and can be scaled to get a sense of the economic development opportunities associated with other wind scenarios. This report can also inform stakeholders in other states about the potential economic impacts associated with the development of 1,000 MW of new wind power generation and the relationships of different elements in the state economy.

  5. 2020-21 Final Resource Adequacy Assessment

    E-Print Network [OSTI]

    1.15 GW · Solar PV 12.7 GW · Current US installed 15.9 GW · Projected by 2021 for PNW 450 MW · Wind Assessment · Using Wind/Solar to Fill the Gap · Potential Recommendations for Council 2 #12;2020 Final retires 730/670 MW · Total loss of 1,330/1,192 MW (nameplate/winter capacity) · Load change 2020 to 2021

  6. Economic Analysis of a 3MW Biomass Gasification Power Plant

    E-Print Network [OSTI]

    Cattolica, Robert; Lin, Kathy

    2009-01-01

    Collaborative, Biomass gasification / power generationANALYSIS OF A 3MW BIOMASS GASIFICATION POWER PLANT R obert Cas a feedstock for gasification for a 3 MW power plant was

  7. bectso-10mw | netl.doe.gov

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifiesValidationENCOAL® Mild CoalSNOX(tm)43 10-MW

  8. Capacity Markets for Electricity

    E-Print Network [OSTI]

    Creti, Anna; Fabra, Natalia

    2004-01-01

    and design of electricity capacity markets. Our work has twoMarkets for Electricity capacity markets, and so, when thesemain features of electricity capacity markets. We have used

  9. PG&E Plans for 500 MW of PV

    Office of Energy Efficiency and Renewable Energy (EERE)

    PG&E has developed a plan to install 500 MW of PV by the year 2015. The plan calls for 250 MW to be acquired through Power Purchase Agreements (PPA) and the other 250 MW to be purchased and owned by the utility. PG&E presented the plan at a public forum on April 27, 2009. A copy of the power point presentation is attached.

  10. Economic Analysis of a 3MW Biomass Gasification Power Plant

    E-Print Network [OSTI]

    Cattolica, Robert; Lin, Kathy

    2009-01-01

    Collaborative, Biomass gasification / power generationANALYSIS OF A 3MW BIOMASS GASIFICATION POWER PLANT R obert Cbiomass. Figure 1: Biomass Gasification to Power Process

  11. Why Cogeneration? 24MW of local renewable energy

    E-Print Network [OSTI]

    Why Cogeneration? · 24MW of local renewable energy · Reduced emissions and cleaner air · Retain 300 Wood Chips Sawdust Pulp Paper Emissions Production #12;Port Townsend Paper - Cogeneration Biomass

  12. Economic Analysis of a 3MW Biomass Gasification Power Plant

    E-Print Network [OSTI]

    Cattolica, Robert; Lin, Kathy

    2009-01-01

    Collaborative, Biomass gasification / power generationANALYSIS OF A 3MW BIOMASS GASIFICATION POWER PLANT R obert Cinvolved in the gasification of biomass to produce gas are

  13. FERC Handbook for Hydroelectric Project Licensing and 5 MW Exemptions...

    Open Energy Info (EERE)

    FERC Handbook for Hydroelectric Project Licensing and 5 MW Exemptions from Licensing Jump to: navigation, search OpenEI Reference LibraryAdd to library PermittingRegulatory...

  14. A 500 MW annular beam relativistic klystron

    SciTech Connect (OSTI)

    Fazio, M.V.; Haynes, W.B.; Carlsten, B.E.; Stringfield, R.M.

    1994-10-01

    This paper describes the experimental development of a long pulse, high current, annular beam relativistic klystron amplifier. The desired performance parameters are 1 GW output power and 1 {mu}s pulse length with an operating frequency of 1.3 GHz. The electron beam voltage and current are nominally 600 kV and 5 kA. Peak powers approaching 500 MW have been achieved in pulses of 1 {mu}s nominal baseline-to-baseline duration. The half power pulse width is 0.5 {mu}s. These pulses contain an energy of about 160 J. The design of this class of tube presents some unique challenges, particularly in the output cavity. The output cavity must exhibit a very low gap shunt impedance in order to obtain reasonable conversion efficiency from the low impedance modulated electron beam to microwave power, while still maintaining a reasonable loaded Q for mode purity. The physics of this device is dominated by space charge effects which strongly impact the design. Current experimental results and theoretical design considerations for this class of tube, and scaling to higher frequency operation, suitable for the Next Linear Collider are discussed.

  15. br Owner br Facility br Type br Capacity br MW br Commercial br Online

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page| Open Energy Information Serbia-EnhancingEtGeorgia:Illinois:WizardYates County,Zena,architecture Homeblack outOwner br

  16. ,,,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: AlternativeMonthly","10/2015"Monthly","10/2015" ,"Release7 Relative Standard Errors for Table 5.7;"

  17. ,,,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: AlternativeMonthly","10/2015"Monthly","10/2015" ,"Release7 Relative Standard Errors for Table

  18. ,,,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Customers",,,,,"Energy Sold Back MWh"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: AlternativeMonthly","10/2015"Monthly","10/2015" ,"Release7 Relative Standard Errors for

  19. Fact Sheet: Beacon Power 20 MW Flywheel Frequency Regulation...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Beacon Power will design, build, and operate a utility-scale 20 MW flywheel energy storage plant at the Humboldt Industrial Park in Hazle Township, PA for Hazle Spindle LLC....

  20. Latest Results in SLAC 75-MW PPM Klystrons

    SciTech Connect (OSTI)

    Sprehn, D.; Caryotakis, G.; Haase, A.; Jongewaard, E.; Laurent, L.; Pearson, C.; Phillips, R.; /SLAC

    2006-03-06

    75 MW X-band klystrons utilizing Periodic Permanent Magnet (PPM) focusing have been undergoing design, fabrication and testing at the Stanford Linear Accelerator Center (SLAC) for almost nine years. The klystron development has been geared toward realizing the necessary components for the construction of the Next Linear Collider (NLC). The PPM devices built to date which fit this class of operation consist of a variety of 50 MW and 75 MW devices constructed by SLAC, KEK (Tsukuba, Japan) and industry. All these tubes follow from the successful SLAC design of a 50 MW PPM klystron in 1996. In 2004 the latest two klystrons were constructed and tested with preliminary results reported at EPAC2004. The first of these two devices was tested to the full NLC specifications of 75 MW, 1.6 microseconds pulse length, and 120 Hz. This 14.4 kW average power operation came with a tube efficiency >50%. The most recent testing of these last two devices will be presented here. Design and manufacturing issues of the latest klystron, due to be tested by the Fall of 2005, are also discussed.

  1. Response of the Los Azufres Geothermal Field to Four Years of 25 MW Wellhead Generation

    SciTech Connect (OSTI)

    Kruger, P.; Ortiz, J.; Miranda, G.; Gallardo, M.

    1987-01-20

    Production and chemical data have been compiled and analyzed on a six-month averaged basis for the first four years of electric energy generation with five 5-MW wellhead generators at the Los Azufres geothermal field. The data were evaluated with respect to the extent of observable thermal drawdown of the reservoir from 25 MW of generation in relation to the estimated capacity of the field of several hundred megawatts of power. The analysis updates the previous one compiled after the first two years of continuous production, at which time the results indicated that differences in reservoir temperature estimated from geochemical thermometers and wellhead production data were not statistically significant based on the number of data and the standard deviations. Analysis of the data after four years of operation were made for the larger number of data and smaller standard deviations. The results review the adequacy of the sampling frequency and the reliability of the measurements from statistical t-Test of the means of the first and second two-year periods. 3 figs., 5 tabs., 20 refs.

  2. Refinery Capacity Report

    Gasoline and Diesel Fuel Update (EIA)

    refinery as of January 1, 2006 Tables 1 Number and Capacity of Operable Petroleum Refineries by PAD District and State as of January 1, 2006 PDF 2 Production Capacity of...

  3. Shannon Capacity Ramsey Numbers

    E-Print Network [OSTI]

    Radziszowski, Stanislaw P.

    Shannon Capacity Ramsey Numbers Old links between Shannon and Ramsey New links between Shannon and Ramsey Bounds on Shannon Capacity and Ramsey Numbers from Product of Graphs Xiaodong Xu1 Stanislaw Institute of Technology, NY, USA March 2014 1/24 #12;Shannon Capacity Ramsey Numbers Old links between

  4. Development Engineer (m/w) Innovation Opto-electronic Devices

    E-Print Network [OSTI]

    Giger, Christine

    . nanograde's current materials pipeline includes materials for displays, lighting panels and solar cellsDevelopment Engineer (m/w) Innovation Opto-electronic Devices nanograde, with of ces in CH material problems in high-margin applications for mobile, display, lighting and energy applications

  5. Development of a 50 MW 30 GHz Gyroklystron Amplifier

    SciTech Connect (OSTI)

    Michael Read; Wesely Lawson, Lawrence Ives, Jeff Neilson

    2009-05-20

    DOE requires sources for testing of high gradient accelerator structures. A power of 50 MW is required at K and Ka band. The pulse length must be ~ 1 microsecond and the pulse repetition frequency at least 100 Hz. At least some applications may require phase stability not offered by a free running oscillator. CCR proposed to build a 50 MW 30 GHz gyrklystron amplifier. This approach would give the required phase stability. The frequency was at the second harmonic of the cycltron frequency and used the TE02 mode. This makes it possible to design a device without an inner conductor, and with a conventional (non-inverted) MIG. This minimizes cost and the risk due to mechanical alignment issues. A detailed design of the gyroklystron was produced. The design was based on simulations of the cavity(ies), electron gun, output coupler and output window. Two designs were produced. One was at the fundamental of the cyclotron frequency. Simulations predicted an output power of 72 MW with an efficiency of 48%. The other was at the second harmonic, producing 37 MW with an efficiency of 37%.

  6. ORISE: Capacity Building

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Capacity Building Because public health agencies must maintain the resources to respond to public health challenges, critical situations and emergencies, the Oak Ridge Institute...

  7. Low Beam Voltage, 10 MW, L-Band Cluster Klystron

    SciTech Connect (OSTI)

    Teryaev, V.; /Novosibirsk, IYF; Yakovlev, V.P.; /Fermilab; Kazakov, S.; /KEK, Tsukuba; Hirshfield, J.L.; /Yale U. /Omega-P, New Haven

    2009-05-01

    Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

  8. Liquid heat capacity lasers

    DOE Patents [OSTI]

    Comaskey, Brian J. (Walnut Creek, CA); Scheibner, Karl F. (Tracy, CA); Ault, Earl R. (Livermore, CA)

    2007-05-01

    The heat capacity laser concept is extended to systems in which the heat capacity lasing media is a liquid. The laser active liquid is circulated from a reservoir (where the bulk of the media and hence waste heat resides) through a channel so configured for both optical pumping of the media for gain and for light amplification from the resulting gain.

  9. Shaped Offset QPSK Capacity

    E-Print Network [OSTI]

    Sahin, Cenk

    2012-08-31

    In this work we compute the capacities and the pragmatic capacities of military-standard shaped-offset quadrature phase-shift keying (SOQPSK-MIL) and aeronautical telemetry SOQPSK (SOQPSK-TG). In the pragmatic approach, SOQPSK is treated as a...

  10. Knudsen heat capacity

    SciTech Connect (OSTI)

    Babac, Gulru; Reese, Jason M.

    2014-05-15

    We present a “Knudsen heat capacity” as a more appropriate and useful fluid property in micro/nanoscale gas systems than the constant pressure heat capacity. At these scales, different fluid processes come to the fore that are not normally observed at the macroscale. For thermodynamic analyses that include these Knudsen processes, using the Knudsen heat capacity can be more effective and physical. We calculate this heat capacity theoretically for non-ideal monatomic and diatomic gases, in particular, helium, nitrogen, and hydrogen. The quantum modification for para and ortho hydrogen is also considered. We numerically model the Knudsen heat capacity using molecular dynamics simulations for the considered gases, and compare these results with the theoretical ones.

  11. Forward capacity market CONEfusion

    SciTech Connect (OSTI)

    Wilson, James F.

    2010-11-15

    In ISO New England and PJM it was assumed that sponsors of new capacity projects would offer them into the newly established forward centralized capacity markets at prices based on their levelized net cost of new entry, or ''Net CONE.'' But the FCCMs have not operated in the way their proponents had expected. To clear up the CONEfusion, FCCM designs should be reconsidered to adapt them to the changing circumstances and to be grounded in realistic expectations of market conduct. (author)

  12. The SANS facility at the Pitesti 14MW TRIGA reactor

    SciTech Connect (OSTI)

    Ionita, I. [Institute for Nuclear Research (Romania)], E-mail: ionionita@lycos.com; Grabcev, B.; Todireanu, S. [National Institute of Materials Physics (NIMP) (Romania); Constantin, F. [National Institute of Physics and Nuclear Engineering (Romania); Shvetsov, V. [Joint Institute for Nuclear Research (Russian Federation); Anghel, E. [Institute for Nuclear Research (Romania); Popescu, G. [National College Alexandru Odobescu (Romania); Mincu, M.; Datcu, A. [Institute for Nuclear Research (Romania)

    2006-12-15

    The SANS facility existing at the Pitesti 14MW TRIGA reactor is presented. The main characteristics and the preliminary evaluation of the installation performances are given. A monochromatic neutron beam with 1.5 A {<=} {lambda} {<=} 5 A is produced by a mechanical velocity selector with helical slots. A fruitful partnership was established between INR Pitesti (Romania) and JINR Dubna (Russia). The first step in this cooperation consists in the manufacturing in Dubna of a battery of gas-filled positional detectors devoted to the SANS instrument.

  13. Latest developments on the Dutch 1MW free electron maser

    SciTech Connect (OSTI)

    Caplan, M. [Lawrence Livermore National Laboratory, 7000 East Ave, L-637 Livermore California, 94551 (United States); Verhoeven, A.G.; Urbanus, W. [FOM Instituut voor Plasma Fysica, Rijnhuizen, P.O. Box 1207, 3430 BE Nieuwegein (The Netherlands)

    1999-05-01

    The FOM Institute (Rijnhuizen, Netherlands), as part of their fusion technology program, has undertaken the development of a Free Electron Maser with the goal of producing 1MW long pulse to CW microwave output in the range 130 GHz{endash}250GHz with wall plug efficiencies of 60{percent}. This project has been carried out as a collaborative effort with Institute of Applied Physics, Nizhny Novgorod Russia, Kurchatov Institute, Moscow Russia, Lawrence Livermore Laboratory, U.S.A and CPI, U.S.A. The key design features of this FEM consists first of a conventional DC acceleration system at high voltage (2MV) which supplies only the unwanted beam interception current and a depressed collector system at 250kV which provides the main beam power. Low body current interception ({lt}25mA) is ensured by using robust inline beam focussing, a low emittance electron gun with halo suppression and periodic magnet side array focussing in the wiggler. The second key feature is use of a low-loss step corrugated waveguide circuit for broad band CW power handling and beam/RF separation. Finally, the required interaction efficiency and mode control is provided by a two stage stepped wiggler. The FEM has been constructed and recently undergone initial short pulse ({lt}10 usec) testing in an inverted mode with the depressed collector absent. Results to date have demonstrated 98.8{percent} beam transmission (over 5 Meters) at currents as high as 8.4 Amps, with 200GHz microwave output at 700kW. There has been good agreement between theory and experiment at the beam current levels tested so far. Details of the most recent experimental results will be presented, in particular the output frequency characteristics with detailed comparisons to theory. The immediate future plans are to operate the system at the design value of 12 Amps with at least 1MW output. The system will then be reconfigured with a 3 stage depressed collector to demonstrate, in the next year, long pulse operation (100 msec) and high wall plug efficiency. Long term future plans call for upgrading the FEM to 2MW and extrapolations up to 5MW are shown to be theoretically possible. {copyright} {ital 1999 American Institute of Physics.}

  14. MHK Projects/40MW Lewis project | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History View NewTexas:Montezuma,Information MHKMHK ISDB/Sensors/SmartMHKInformation SpeedMHKMHK40MW

  15. 5-MW Dynamometer Ground Breaking | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Financing ToolInternationalReportOffice | DepartmentVery1, in: A.R.Rulemakings -Statement of5-MW

  16. Puna Geothermal Venture 8MW Expantion | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to:EA EIS Report Url JumpTechnology JumpPrueba 1Venture 8MW Expantion Jump to:

  17. Stochastic capacity modeling to support demand/capacity gap planning

    E-Print Network [OSTI]

    Niles, Augusta (Augusta L.)

    2014-01-01

    Capacity strategy has established methods of dealing with uncertainty in future demand. This project advances the concept of capacity strategy under conditions of uncertainty in cases where capacity is the primary source ...

  18. Triggering of the 1999 MW 7.1 Hector Mine earthquake by aftershocks of the 1992 MW 7.3 Landers earthquake

    E-Print Network [OSTI]

    Becker, Thorsten W.

    and prediction; 7209 Seismology: Earthquake dynamics and mechanics; KEYWORDS: aftershocks, foreshocks, HectorTriggering of the 1999 MW 7.1 Hector Mine earthquake by aftershocks of the 1992 MW 7.3 Landers earthquake Karen R. Felzer, Thorsten W. Becker, Rachel E. Abercrombie, Go¨ran Ekstro¨m, and James R. Rice1

  19. Dual capacity reciprocating compressor

    DOE Patents [OSTI]

    Wolfe, Robert W. (Wilkinsburg, PA)

    1984-01-01

    A multi-cylinder compressor 10 particularly useful in connection with northern climate heat pumps and in which different capacities are available in accordance with reversing motor 16 rotation is provided with an eccentric cam 38 on a crank pin 34 under a fraction of the connecting rods, and arranged for rotation upon the crank pin between opposite positions 180.degree. apart so that with cam rotation on the crank pin such that the crank throw is at its normal maximum value all pistons pump at full capacity, and with rotation of the crank shaft in the opposite direction the cam moves to a circumferential position on the crank pin such that the overall crank throw is zero. Pistons 24 whose connecting rods 30 ride on a crank pin 36 without a cam pump their normal rate with either crank rotational direction. Thus a small clearance volume is provided for any piston that moves when in either capacity mode of operation.

  20. Dual capacity reciprocating compressor

    DOE Patents [OSTI]

    Wolfe, R.W.

    1984-10-30

    A multi-cylinder compressor particularly useful in connection with northern climate heat pumps and in which different capacities are available in accordance with reversing motor rotation is provided with an eccentric cam on a crank pin under a fraction of the connecting rods, and arranged for rotation upon the crank pin between opposite positions 180[degree] apart so that with cam rotation on the crank pin such that the crank throw is at its normal maximum value all pistons pump at full capacity, and with rotation of the crank shaft in the opposite direction the cam moves to a circumferential position on the crank pin such that the overall crank throw is zero. Pistons whose connecting rods ride on a crank pin without a cam pump their normal rate with either crank rotational direction. Thus a small clearance volume is provided for any piston that moves when in either capacity mode of operation. 6 figs.

  1. Geothermal Plant Capacity Factors

    SciTech Connect (OSTI)

    Greg Mines; Jay Nathwani; Christopher Richard; Hillary Hanson; Rachel Wood

    2015-01-01

    The capacity factors recently provided by the Energy Information Administration (EIA) indicated this plant performance metric had declined for geothermal power plants since 2008. Though capacity factor is a term commonly used by geothermal stakeholders to express the ability of a plant to produce power, it is a term frequently misunderstood and in some instances incorrectly used. In this paper we discuss how this capacity factor is defined and utilized by the EIA, including discussion on the information that the EIA requests from operations in their 923 and 860 forms that are submitted both monthly and annually by geothermal operators. A discussion is also provided regarding the entities utilizing the information in the EIA reports, and how those entities can misinterpret the data being supplied by the operators. The intent of the paper is to inform the facility operators as the importance of the accuracy of the data that they provide, and the implications of not providing the correct information.

  2. The 125 MW Upper Mahiao geothermal power plant

    SciTech Connect (OSTI)

    Forte, N.

    1996-12-31

    The 125 MW Upper Mahiao power plant, the first geothermal power project to be financed under a Build-Own-Operate-and-Transfer (BOOT) arrangement in the Philippines, expected to complete its start-up testing in August of this year. This plant uses Ormat`s environmentally benign technology and is both the largest geothermal steam/binary combined cycle plant as well as the largest geothermal power plant utilizing air cooled condensers. The Ormat designed and constructed plant was developed under a fast track program, with some two years from the April 1994 contract signing through design, engineering, construction and startup. The plant is owned and operated by a subsidiary of CalEnergy Co., Inc. and supplies power to PNOC-Energy Development Corporation for the National Power Corporation (Napocor) national power grid in the Philippines.

  3. Capacity Demand Power (GW)

    E-Print Network [OSTI]

    California at Davis, University of

    Capacity Demand Power (GW) Hour of the Day The "Dip" Electricity Demand in Electricity Demand Every weekday, Japan's electricity use dips about 6 GW at 12 but it also shows that: · Behavior affects naHonal electricity use in unexpected ways

  4. Seventh Northwest Conservation and Electric Power Plan nwcouncil.org/7thplan 9-1

    E-Print Network [OSTI]

    and Tables Figure 9 - 1: Pacific Northwest Electricity Power Supply ­ Installed Nameplate Capacity.................. 6 Figure 9 - 3: Generating Additions and Retirements (Installed Capacity.........................................................................................................................................20 Solar

  5. Model Validation at the 204-MW New Mexico Wind Energy Center

    SciTech Connect (OSTI)

    Muljadi, E.; Butterfield, C. P.; Ellis, A.; Mechenbier, J.; Hochheimer, J.; Young, R.; Miller, N.; Delmerico, R.; Zavadil, R.; Smith, J. C.

    2006-06-01

    Poster for WindPower 2006 held June 4-7, 2006, in Pittsburgh, PA, describing model validation at the 204-MW New Mexico Wind Energy Center.

  6. NREL Controllable Grid Interface for Testing MW-Scale Wind Turbine

    Office of Scientific and Technical Information (OSTI)

    Controllable Grid Interface for Testing MW-Scale Wind Turbine Generators (Poster) McDade, M.; Gevorgian, V.; Wallen, R.; Erdman, W. 17 WIND ENERGY WIND TURBINE TESTING;...

  7. Baseline System Costs for 50.0 MW Enhanced Geothermal System...

    Open Energy Info (EERE)

    Baseline System Costs for 50.0 MW Enhanced Geothermal System -- A Function of: Working Fluid, Technology, and Location Geothermal Project Jump to: navigation, search Last modified...

  8. How and why Tampa Electric Company selected IGCC for its next generating capacity addition

    SciTech Connect (OSTI)

    Pless, D.E. )

    1992-01-01

    As the title indicates, the purpose of this paper is to relate how and why Tampa Electric Company decided to select the Integrated Gasification Combined Cycle (IGCC) for their next capacity addition at Polk Power Station, Polk Unit No. 1. For a complete understanding of this process, it is necessary to review the history related to the initial formulation of the IGCC concept as it was proposed to the Department of Energy (DOE) Clean Coal Initiative Round Three. Further, it is important to understand the relationship between Tampa Electric Company and TECO Pay Services Corporation (TPS). TECO Energy, Inc. is an energy related holding company with headquarters in Tampa, Florida. Tampa Electric Company is the principal, wholly-owned subsidiary of TECO Energy, Inc. Tampa Electric Company is an investor-owned electric utility with about 3200 MW of generation capacity of which 97% is coal fired. Tampa Electric Company serves about 2,000 square miles and approximately 470,000 customers, in west central Florida, primarily in and around Hillsborough County and Tampa, Florida. Tampa Electric Company generating units consist of coal fired units ranging in size from a 110 MW coal fired cyclone unit installed in 1957 to a 450 MW pulverized coal unit with wet limestone flue gas desulfurization installed in 1985. In addition, Tampa Electric Company has six (6) No. 6 oil fired steam units totaling approximately 220 MW. Five (5) of these units, located at the Hookers Point Station, were installed in the late 1940's and early 1950's. Tampa Electric also has about 150 MW of No. 2 oil fired start-up and peaking combustion turbines. The company also owns a 1966 vintage 12 MW natural gas fired steam plant (Dinner Lake) and two nO. 6 oil fired diesel units with heat recovery equipment built in 1983 (Phillips Plant).

  9. CSTI high capacity power

    SciTech Connect (OSTI)

    Winter, J.M.

    1994-09-01

    The SP-100 program was established in 1983 by DOD, DOE, and NASA as a joint program to develop the technology necessary for space nuclear power systems for military and civil application. During FY86 and 87, the NASA SP-100 Advanced Technology Program was devised to maintain the momentum of promising technology advancement efforts started during Phase I of SP-100 and to strengthen, in key areas, the chances for successful development and growth capability of space nuclear reactor power systems for future space applications. In FY88, the Advanced Technology Program was incorporated into NASA`s new Civil Space Technology Initiative (CSTI). The CSTI Program was established to provide the foundation for technology development in automation and robotics, information, propulsion, and power. The CSTI High Capacity Power Program builds on the technology efforts of the SP-100 program, incorporates the previous NASA SP-100 Advanced Technology project, and provides a bridge to NASA Project Pathfinder. The elements of CSTI High Capacity Power development include Conversion Systems, Thermal Management, Power Management, System Diagnostics, and Environmental Interactions. Technology advancement in all areas, including materials, is required to assure the high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems. The overall program will develop and demonstrate the technology base required to provide a wide range of modular power systems as well as allowing mission independence from solar and orbital attitude requirements. Several recent advancements in CSTI High Capacity power development will be discussed.

  10. Alstom 3-MW Wind Turbine Installed at NWTC (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2011-09-01

    The 3-MW Alstom wind turbine was installed at NREL's NWTC in October 2010. Test data will be used to validate advanced turbine design and analysis tools. NREL signed a Cooperative Research and Development Agreement with Alstom in 2010 to conduct certification testing on the company's 3-MW ECO 100 wind turbine and to validate models of Alstom's unique drivetrain concept. The turbine was installed at NREL's National Wind Technology Center (NWTC) in October 2010 and engineers began certification testing in 2011. Tests to be conducted by NREL include a power quality test to finalize the International Electrotechnical Commission (IEC) requirements for type certification of the 60-Hz unit. The successful outcome of this test will enable Alstom to begin commercial production of ECO 100 in the United States. NREL also will obtain additional measurements of power performance, acoustic noise, and system frequency to complement the 50 Hz results previously completed in Europe. After NREL completes the certification testing on the ECO 100, it will conduct long-term testing to validate gearbox performance to gain a better understanding of the machine's unique ALSTOM PURE TORQUE{trademark} drivetrain concept. In conventional wind turbines, the rotor is supported by the shaft-bearing gearbox assembly. Rotor loads are partially transmitted to the gearbox and may reduce gearbox reliability. In the ALSTOM PURE TORQUE concept, the rotor is supported by a cast frame running through the hub, which transfers bending loads directly to the tower. Torque is transmitted to the shaft through an elastic coupling at the front of the hub. According to Alstom, this system will increase wind turbine reliability and reduce operation and maintenance costs by isolating the gearbox from rotor loads. Gearbox reliability has challenged the wind energy industry for more than two decades. Gearbox failures require expensive and time-consuming replacement, significantly increasing the cost of wind plant operation while reducing the plant's power output and revenue. To solve gearbox reliability issues, NREL launched a Gearbox Reliability Collaborative (GRC) in 2006 and brought together the world's leading turbine manufacturers, consultants, and experts from more than 30 companies and organizations. GRC's goal was to validate the typical design process-from wind turbine system loads to bearing ratings-through a comprehensive dynamometer and field-test program. Design analyses will form a basis for improving reliability of future designs and retrofit packages. Through its study of Alstom's Eco 100 gearbox, NREL can compare its GRC model gearbox with Alstom's and add the results to the GRC database, which is helping to advance more reliable wind turbine technology.

  11. Fuel strategy for 2 MW SF-TMSR

    SciTech Connect (OSTI)

    Zhu, Zhiyong; Lin, Jun; Cao, Changqing; Zhang, Haiqing; Zhu, Tianbao; Li, Xiaoyun [Center for Thorium Molten Salt Reactor System, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, No.2019 Jialuo Road, Jiading District, Shanghai 201800 (China)

    2013-07-01

    China has launched a series of projects for developing high performance nuclear energy systems. The 2 MW solid fuel thorium based molten salt reactor (TMSR-SF) is one of these projects, which uses TRISO fuel elements as the fuel carrier and the FLiBe molten salt (2LiF-BeF{sub 2}) as the coolant. TRISO fuel elements have been well developed in respect to manufacturing, testing experiments inside and outside reactors as well as their successful application in HTGRs. The application of LEU (low enriched uranium) spherical TRISO fuel elements in TMSR-SF can be safely conducted through careful control of temperature and power density. Although the soaking of molten salt into graphite has shown no damage to the graphite material as experienced by ORNL group in the sixties last century, the compatibility of FLiBe salt with graphite covering of the fuel elements should be tested before the application. It is expected that TMSR-SF can be an appropriate test reactor for high performance fuel element development. (authors)

  12. Development of a 50 MW Multiple Beam Klystron

    SciTech Connect (OSTI)

    Ives, R Lawrence; Ferguson, Patrick; Read, Michael; Collins, George

    2007-10-31

    The goal of this program was to develop a 50 MW, multiple beam klystron at 11.424 GHz. The device uses eight electron guns and beam lines to achieve the required power level at a beam voltage of 190 kV, consistent with solid state power supplies. The electron gun operates with confined flow focusing, which is unique among current multiple beam sources, and allows operation at power levels consistent with producing 10s of MWs of pulsed RF power. The circuit consists of a ring resonator input cavity, eight sets of buncher cavities, and a ring resonator output cavity. The RF output power is coupled into four rectangular waveguides equally spaced around the klystron. Eight individual collectors absorb the spent beam power in each beam. The klystron operates in a solenoid. The principle challenges in the design included development of the beam optics using confined flow focusing, shaping of the magnetic field in the gun region to avoid beam spiraling, coupling input power equally to all eight beam lines from a single input, and obtaining the required frequency and Q in the output cavity. The mechanical design was particularly complex due to the large parts count, number of braze and weld joints, and close proximity of the beam lines that limited access. Addressing vacuum leaks and cold testing the complex structures was particularly troublesome. At the conclusion of the program, the klystron is experiencing several vacuum leaks that are under repair. Efforts will continue to seal and test the klystron.

  13. Ris-R-Report Multi-MW wind turbine power curve

    E-Print Network [OSTI]

    Risø-R-Report Multi-MW wind turbine power curve measurements using remote sensing instruments Wagner, Michael Courtney Title: Multi-MW wind turbine power curve measurements using remote sensing (max. 2000 char.): Power curve measurement for large wind turbines requires taking into account more

  14. Grid Simulator for Testing MW-Scale Wind Turbines at NREL (Poster)

    SciTech Connect (OSTI)

    Gevorgian, V.; McDade, M.; Wallen, R.; Mendoza, I.; Shirazi, M.

    2011-05-01

    As described, an initiative by NREL to design and construct a 9-MVA grid simulator to operate with the existing 2.5 MW and new upcoming 5-MW dynamometer facilities will fulfill this role and bring many potential benefits to the U.S. wind industry with the ultimate goal of reducing wind energy integration costs.

  15. A 60 mW per Lane, 4 23-Gb/s 27 1 PRBS Generator

    E-Print Network [OSTI]

    Voinigescu, Sorin Petre

    ) generators and checkers are widely used for testing the correct functionality of high speed digital circuits reports an ultra-low-power 27 ­ 1 PRBS generator with 4, appropriately delayed, parallel output streams circuitry. The 4-channel PRBS generator consumes 235 mW from 2.5 V, which results in only 60 mW per output

  16. Transmission Capacity Forum

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired SolarAbout / Transforming Y-12Capacity-Forum Sign In About | Careers |

  17. Refinery Capacity Report

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet) Wyoming Dry NaturalPrices1Markets160Product:7a. Space5,168Capacity Report

  18. Refinery Capacity Report

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet) Wyoming Dry NaturalPrices1Markets160Product:7a. Space5,168Capacity Report5

  19. Refinery Capacity Report

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet) Wyoming Dry NaturalPrices1Markets160Product:7a. Space5,168Capacity

  20. Refinery Capacity Report

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet) Wyoming Dry NaturalPrices1Markets160Product:7a. Space5,168Capacity Operable

  1. Refinery Capacity Report

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet) Wyoming Dry NaturalPrices1Markets160Product:7a. Space5,168Capacity

  2. Tracking Progress Last updated 10/7/2013 Installed Capacity 1

    E-Print Network [OSTI]

    2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 Capacity (MW) Wind Solar Small Hydro Large Hydro,813 Large Hydro 11,890 11,755 11,755 12,114 12,103 12,194 11,945 12,226 12,226 12,257 12,297 12,297 Small 2008 2009 2010 2011 2012 Energy (GWh) Wind Solar Small Hydro Large Hydro Natural Gas Nuclear Geothermal

  3. Operating and Maintaining a 465MW Cogeneration Plant 

    E-Print Network [OSTI]

    Theisen, R. E.

    1988-01-01

    experienced three total interruptions of their steam plant in early 1986, and in all cases, the automatic high pressure extraction system of the steam turbine generator quickly and evenly increased steam flow and maintained the chemical plant at capacity... of construction. DESIGN SUMMARY The plant consists of five 75,OOOkW Model PG7IIIE General Electric gas turbine generators. five three-pressure level Henry Vogt heat recovery boilers, one 137,000kW extraction/induction/ 237 condensing General Electric steam...

  4. 20 MW Pulse Amplifier Klystron with Multiple Frequency Two-Gap Bunching Resonators for Linear Electron Accelerators

    E-Print Network [OSTI]

    Simonov, K G; Mamontov, A V

    2008-01-01

    20 MW Pulse Amplifier Klystron with Multiple Frequency Two-Gap Bunching Resonators for Linear Electron Accelerators

  5. The Role of M(W) in Precision Studies of the Standard Model

    E-Print Network [OSTI]

    G. Degrassi; P. Gambino; M. Passera; A. Sirlin

    1997-11-28

    Recent calculations have significantly decreased the scheme and residual scale dependence of basic radiative corrections of the Standard Electroweak Model. This leads to a theoretically accurate prediction of the W-boson mass M(W), as well as a reduced upper bound for the Higgs boson mass M(H). The implications of a precise M(W) measurement on the M(H) estimate are emphasized.

  6. Development of a 2 MW CW Waterload for Electron Cyclotron Heating Systems

    SciTech Connect (OSTI)

    R. Lawrence,Ives; Maxwell Mizuhara; George Collins; Jeffrey Neilson; Philipp Borchard

    2012-11-09

    Calabazas Creek Research, Inc. developed a load capable of continuously dissipating 2 MW of RF power from gyrotrons. The input uses HE11 corrugated waveguide and a rotating launcher to uniformly disperse the power over the lossy surfaces in the load. This builds on experience with a previous load designed to dissipate 1 MW of continuous RF power. The 2 MW load uses more advanced RF dispersion to double the capability in the same size device as the 1 MW load. The new load reduces reflected power from the load to significantly less than 1 %. This eliminates requirements for a preload to capture reflected power. The program updated control electronics that provides all required interlocks for operation and measurement of peak and average power. The program developed two version of the load. The initial version used primarily anodized aluminum to reduce weight and cost. The second version used copper and stainless steel to meet specifications for the ITER reactor currently under construction in France. Tests of the new load at the Japanese Atomic Energy Agency confirmed operation of the load to a power level of 1 MW, which is the highest power currently available for testing the load. Additional tests will be performed at General Atomics in spring 2013. The U.S. ITER organization will test the copper/stainless steel version of the load in December 2012 or early in 2013. Both loads are currently being marketed worldwide.

  7. CAPACITY BUILDING ACTIVITIES Public Health

    E-Print Network [OSTI]

    Hill, Wendell T.

    CAPACITY BUILDING ACTIVITIES School of Public Health Dean Principal Investigator Community Advisory System Faculty & Students School of Public Health Faculty & Students Prince George's County Washington, D.C. Community Members Practitioners, Residents and Public Health Professionals Research Projects Forum (CAC

  8. Tucson Request for Proposal for 1-5 MW PV PPA

    Office of Energy Efficiency and Renewable Energy (EERE)

    The mission of Tucson Water, a Department of the City of Tucson (the City), is to ensure that its customers receive high quality water and excellent service in a cost efficient, safe and environmentally responsible manner. In the interest of furthering Tucson Waters mission, the City is seeking a Contractor to finance, design, build, commission, own, operate and maintain up to a 1 megawatt (MW) DCSTC hotovoltaic (PV) system. The City also seeks an option for expanding the PV system up to a total of 5 MW DCSTC PV.

  9. 2 MW Active Bouncer Converter Design for Long Pulse Klystron Modulators

    E-Print Network [OSTI]

    Aguglia, D

    2012-01-01

    This paper presents some design issues of a 2 MW interleaved buck converter which is used as an active bouncer droop compensator for a 5.5MW long pulse klystron modulator. This novel design concept presents many challenges in terms of voltage ripple versus pulse rise-time. Issues related to the voltage ripple specification versus output filter design are discussed in detail. The design study is analyzed analytically, simulated numerically and is validated by experimental results obtained from a full power prototype.

  10. Worldwide Energy Efficiency Action through Capacity Building...

    Open Energy Info (EERE)

    Worldwide Energy Efficiency Action through Capacity Building and Training (WEACT) Jump to: navigation, search Logo: Worldwide Energy Efficiency Action through Capacity Building and...

  11. Hybrid Zero-capacity Channels

    E-Print Network [OSTI]

    Sergii Strelchuk; Jonathan Oppenheim

    2012-07-04

    There are only two known kinds of zero-capacity channels. The first kind produces entangled states that have positive partial transpose, and the second one - states that are cloneable. We consider the family of 'hybrid' quantum channels, which lies in the intersection of the above classes of channels and investigate its properties. It gives rise to the first explicit examples of the channels, which create bound entangled states that have the property of being cloneable to the arbitrary finite number of parties. Hybrid channels provide the first example of highly cloneable binding entanglement channels, for which known superactivation protocols must fail - superactivation is the effect where two channels each with zero quantum capacity having positive capacity when used together. We give two methods to construct a hybrid channel from any binding entanglement channel. We also find the low-dimensional counterparts of hybrid states - bipartite qubit states which are extendible and possess two-way key.

  12. First Generation 50 MW OTEC Plantship for the Production of Electricity and Desalinated Water

    E-Print Network [OSTI]

    OTC 20957 First Generation 50 MW OTEC Plantship for the Production of Electricity and Desalinated for presentation at the 2010 Offshore Technology Conference held in Houston, Texas, USA, 3­6 May 2010. This paper pressurized anhydrous ammonia as the working fluid to drive turbine-generators to produce electricity; and

  13. Title: Feasibility Study for 20 MW Hybrid Solar and Wind Park in Colombia

    E-Print Network [OSTI]

    Johnson, Eric E.

    1 of 2 Title: Feasibility Study for 20 MW Hybrid Solar and Wind Park in Colombia Principal to assess the Colombian solar and wind resources, looking at different technology options, anticipated performance, and evaluating the economics of solar and wind power technologies. The NMSU team also evaluates

  14. MN 535 Green Manufacturing Fall'04: M-W noon-2PM

    E-Print Network [OSTI]

    Lin, Xi

    of the Manufacturing Process that aims to efficiently use energy, water and raw materials in order to minimize airMN 535 Green Manufacturing Fall'04: M-W noon-2PM Course Objective Provides a systems view and water pollution and generation of solid waste per unit of the manufactured product Class Discussion

  15. LBNE 1.2MW Target Conceptual Design Brian Hartsell, Kris Anderson, James Hylen

    E-Print Network [OSTI]

    McDonald, Kirk

    to calculate the heat load placed in the target at each fin. A detailed map of energy deposition was provided will be presented and analyzed. Target Layout The target is comprised of 48 graphite segments brazed to dual grade 2 GRAPHITE 13.37 Figure 2: 1.2MW Target Cross Section Energy Deposition Energy deposition is used

  16. SHIELDING OF SUPERCONDUCTING COILS FOR A 4-MW MUON-COLLIDER TARGET SYSTEM

    E-Print Network [OSTI]

    McDonald, Kirk

    SHIELDING OF SUPERCONDUCTING COILS FOR A 4-MW MUON-COLLIDER TARGET SYSTEM R.J. Weggel , N. Souchlas intercoil gaps to 40% of the O.D. of the flanking coils. Longitudinal sag of the tungsten shielding vessels an aggregate cross section of 0.1 m2 ; the cryogenic heat leakage may be large. The innermost shielding vessel

  17. Control development for an 18 MW pulsed power converter using a real-time simulation platform

    E-Print Network [OSTI]

    Genton, Charles-Mathieu; Boattini, Fulvio

    2015-01-01

    In the frame of the LHC Injectors Upgrade (LIU) project, a new main power supply (MPS) for the PSBooster accelerator is required. The largest element of the new MPS is the 18 MW main power converter (MPC). The paper presents the design of the MPC control software, using Rapid Control Prototyping.

  18. Earth and Space Science The 2013 Mw 6.2 Khaki-Shonbe (Iran) Earthquake

    E-Print Network [OSTI]

    Elliott, John

    Earth and Space Science The 2013 Mw 6.2 Khaki-Shonbe (Iran) Earthquake: Insights into seismic Studies in Basic Sciences, Zanjan, Iran, 5Department of Geophysics, Colorado School of Mines, Golden, Colorado, USA, 6Seismotectonics Department, Geological Survey of Iran, Tehran, Iran, 7International

  19. Seismic reversal pattern for the 1999 Chi-Chi, Taiwan, MW 7.6 earthquake

    E-Print Network [OSTI]

    Wu, Yih-Min

    Seismic reversal pattern for the 1999 Chi-Chi, Taiwan, MW 7.6 earthquake Yih-Min Wu a , Chien the variations in seismicity patterns in the Taiwan region before and after the Chi-Chi earthquake. We have found that the areas with relatively high seismicity in the eastern Taiwan became abnormally quiet before the Chi

  20. Factory capacity limits Machine dependencies

    E-Print Network [OSTI]

    Foley, Simon

    Factory capacity limits Machine dependencies Employee scheduling Raw material availability Other internal operations (and also possibly the actions of other suppliers that supply raw materials) and at an international workshop at the multi-agent conference (AAMAS'06). Manufacturer Customer demand Penalties for non

  1. Constrained capacity of MIMO Rayleigh fading channels 

    E-Print Network [OSTI]

    He, Wenyan

    2011-08-08

    though) as the deflnition of outage capacity in (2.4). Telatar conjectured that the optimal input covariance matrix Q is a diagonal matrix with the power equally shared among a subset of the transmit antennas [1]. Furthermore, the higher the rate... . . . . . . . . . . . . . . . . . . . . . . . 8 B. Outage Capacity . . . . . . . . . . . . . . . . . . . . . . . 9 III PSK CONSTRAINED MIMO CAPACITY : : : : : : : : : : : : 13 A. PSK Constrained MIMO Capacity . . . . . . . . . . . . . 13 1. The Covariance Matrix...

  2. Online Capacity Identification of Multitier Websites Using

    E-Print Network [OSTI]

    Xu, Cheng-Zhong

    to resource contention and algorithmic overhead for load management [15]. Knowledge about the server capacity

  3. Source area and rupture parameters of the 31 December 1881 Mw = 7.9 Car Nicobar earthquake estimated from tsunamis

    E-Print Network [OSTI]

    Mojzsis, Stephen J.

    Source area and rupture parameters of the 31 December 1881 Mw = 7.9 Car Nicobar earthquake on the India/Andaman plate boundary resulting in 10­60 cm of uplift of the island of Car Nicobar. The rupture., and R. Bilham, Source area and rupture parameters of the 31 December 1881 Mw = 7.9 Car Nicobar

  4. Seismic behavior in central Taiwan: Response to stress evolution following the 1999 Mw 7.6 Chi-Chi earthquake

    E-Print Network [OSTI]

    Wu, Yih-Min

    Seismic behavior in central Taiwan: Response to stress evolution following the 1999 Mw 7.6 Chi of seismicity occurred in the Nantou region of central Taiwan. Among the seismic activities, eight Mw P 5 magnitudes took place from 1900 to 1998. Since the seismicity rate during the Chi-Chi postseismic period has

  5. High capacity immobilized amine sorbents

    DOE Patents [OSTI]

    Gray, McMahan L. (Pittsburgh, PA); Champagne, Kenneth J. (Fredericktown, PA); Soong, Yee (Monroeville, PA); Filburn, Thomas (Granby, CT)

    2007-10-30

    A method is provided for making low-cost CO.sub.2 sorbents that can be used in large-scale gas-solid processes. The improved method entails treating an amine to increase the number of secondary amine groups and impregnating the amine in a porous solid support. The method increases the CO.sub.2 capture capacity and decreases the cost of utilizing an amine-enriched solid sorbent in CO.sub.2 capture systems.

  6. Testing and Modeling of a 3-MW Wind Turbine Using Fully Coupled Simulation Codes (Poster)

    SciTech Connect (OSTI)

    LaCava, W.; Guo, Y.; Van Dam, J.; Bergua, R.; Casanovas, C.; Cugat, C.

    2012-06-01

    This poster describes the NREL/Alstom Wind testing and model verification of the Alstom 3-MW wind turbine located at NREL's National Wind Technology Center. NREL,in collaboration with ALSTOM Wind, is studying a 3-MW wind turbine installed at the National Wind Technology Center(NWTC). The project analyzes the turbine design using a state-of-the-art simulation code validated with detailed test data. This poster describes the testing and the model validation effort, and provides conclusions about the performance of the unique drive train configuration used in this wind turbine. The 3-MW machine has been operating at the NWTC since March 2011, and drive train measurements will be collected through the spring of 2012. The NWTC testing site has particularly turbulent wind patterns that allow for the measurement of large transient loads and the resulting turbine response. This poster describes the 3-MW turbine test project, the instrumentation installed, and the load cases captured. The design of a reliable wind turbine drive train increasingly relies on the use of advanced simulation to predict structural responses in a varying wind field. This poster presents a fully coupled, aero-elastic and dynamic model of the wind turbine. It also shows the methodology used to validate the model, including the use of measured tower modes, model-to-model comparisons of the power curve, and mainshaft bending predictions for various load cases. The drivetrain is designed to only transmit torque to the gearbox, eliminating non-torque moments that are known to cause gear misalignment. Preliminary results show that the drivetrain is able to divert bending loads in extreme loading cases, and that a significantly smaller bending moment is induced on the mainshaft compared to a three-point mounting design.

  7. 50 MW X-BAND RF SYSTEM FOR A PHOTOINJECTOR TEST STATION AT LLNL

    SciTech Connect (OSTI)

    Marsh, R A; Anderson, S G; Barty, C J; Beer, G K; Cross, R R; Ebbers, C A; Gibson, D J; Hartemann, F V; Houck, T L; Adolphsen, C; Candel, A; Chu, T S; Jongewaard, E N; Li, Z; Raubenheimer, T; Tantawi, S G; Vlieks, A; Wang, F; Wang, J W; Zhou, F; Deis, G A

    2011-03-11

    In support of X-band photoinjector development efforts at LLNL, a 50 MW test station is being constructed to investigate structure and photocathode optimization for future upgrades. A SLAC XL-4 klystron capable of generating 50 MW, 1.5 microsecond pulses will be the high power RF source for the system. Timing of the laser pulse on the photocathode with the applied RF field places very stringent requirements on phase jitter and drift. To achieve these requirements, the klystron will be powered by a state of the art, solid-state, high voltage modulator. The 50 MW will be divided between the photoinjector and a traveling wave accelerator section. A high power phase shifter is located between the photoinjector and accelerator section to adjust the phasing of the electron bunches with respect to the accelerating field. A variable attenuator is included on the input of the photoinjector. The distribution system including the various x-band components is being designed and constructed. In this paper, we will present the design, layout, and status of the RF system.

  8. Ultra Clean 1.1MW High Efficiency Natural Gas Engine Powered System

    SciTech Connect (OSTI)

    Zurlo, James; Lueck, Steve

    2011-08-31

    Dresser, Inc. (GE Energy, Waukesha gas engines) will develop, test, demonstrate, and commercialize a 1.1 Megawatt (MW) natural gas fueled combined heat and power reciprocating engine powered package. This package will feature a total efficiency > 75% and ultra low CARB permitting emissions. Our modular design will cover the 1 – 6 MW size range, and this scalable technology can be used in both smaller and larger engine powered CHP packages. To further advance one of the key advantages of reciprocating engines, the engine, generator and CHP package will be optimized for low initial and operating costs. Dresser, Inc. will leverage the knowledge gained in the DOE - ARES program. Dresser, Inc. will work with commercial, regulatory, and government entities to help break down barriers to wider deployment of CHP. The outcome of this project will be a commercially successful 1.1 MW CHP package with high electrical and total efficiency that will significantly reduce emissions compared to the current central power plant paradigm. Principal objectives by phases for Budget Period 1 include: • Phase 1 – market study to determine optimum system performance, target first cost, lifecycle cost, and creation of a detailed product specification. • Phase 2 – Refinement of the Waukesha CHP system design concepts, identification of critical characteristics, initial evaluation of technical solutions, and risk mitigation plans. Background

  9. Capacity Factor Risk At Nuclear Power Plants

    E-Print Network [OSTI]

    Du, Yangbo

    We develop a model of the dynamic structure of capacity factor risk. It incorporates the risk that the capacity factor may vary widely from year-to-year, and also the risk that the reactor may be permanently shutdown prior ...

  10. Neural substrates of cognitive capacity limitations

    E-Print Network [OSTI]

    Buschman, Tim

    Cognition has a severely limited capacity: Adult humans can retain only about four items “in mind”. This limitation is fundamental to human brain function: Individual capacity is highly correlated with intelligence measures ...

  11. On the capacity of bosonic channels

    E-Print Network [OSTI]

    Blake, Christopher Graham

    2011-01-01

    The capacity of the bosonic channel with additive Gaussian noise is unknown, but there is a known lower bound that is conjectured to be the capacity. We have quantified the gap that exists between this known achievable ...

  12. Information Capacity of Energy Harvesting Sensor Nodes

    E-Print Network [OSTI]

    Sharma, Vinod

    Information Capacity of Energy Harvesting Sensor Nodes R Rajesh CABS, DRDO Bangalore, India Email by which the harvested energy is used. We find its Shannon capacity when it is transmitting its observations over an AWGN channel and show that the capacity achieving energy management policies are related

  13. Holocene versus modern catchment erosion rates at 300 MW Baspa II hydroelectric power plant (India, NW Himalaya)

    E-Print Network [OSTI]

    Bookhagen, Bodo

    Holocene versus modern catchment erosion rates at 300 MW Baspa II hydroelectric power plant (India private hydroelectric facility, located at the Baspa River which is an important left-hand tributary

  14. Quick assessment of the fault plane, for the recent event in Southern Greece (14 February 2008, Mw 6.9)

    E-Print Network [OSTI]

    Cerveny, Vlastislav

    Quick assessment of the fault plane, for the recent event in Southern Greece (14 February 2008, Mw.org/index.php?page=current&sub=recent&evt=20080106_GREECE), we issue a quick assessment of the fault plane for the most recent Mw6.9 earthquake in Southern Greece (20080214 at 10:09:23 UTC). Using hypocenter (H) from manual P and Swave picks from 14

  15. Capacity Value of Concentrating Solar Power Plants

    SciTech Connect (OSTI)

    Madaeni, S. H.; Sioshansi, R.; Denholm, P.

    2011-06-01

    This study estimates the capacity value of a concentrating solar power (CSP) plant at a variety of locations within the western United States. This is done by optimizing the operation of the CSP plant and by using the effective load carrying capability (ELCC) metric, which is a standard reliability-based capacity value estimation technique. Although the ELCC metric is the most accurate estimation technique, we show that a simpler capacity-factor-based approximation method can closely estimate the ELCC value. Without storage, the capacity value of CSP plants varies widely depending on the year and solar multiple. The average capacity value of plants evaluated ranged from 45%?90% with a solar multiple range of 1.0-1.5. When introducing thermal energy storage (TES), the capacity value of the CSP plant is more difficult to estimate since one must account for energy in storage. We apply a capacity-factor-based technique under two different market settings: an energy-only market and an energy and capacity market. Our results show that adding TES to a CSP plant can increase its capacity value significantly at all of the locations. Adding a single hour of TES significantly increases the capacity value above the no-TES case, and with four hours of storage or more, the average capacity value at all locations exceeds 90%.

  16. The R and D progress of 4 MW EAST-NBI high current ion source

    SciTech Connect (OSTI)

    Xie, Yahong Hu, Chundong; Liu, Sheng; Xu, Yongjian; Liang, Lizhen; Xie, Yuanlai; Sheng, Peng; Jiang, Caichao; Liu, Zhimin

    2014-02-15

    A high current ion source, which consists of the multi-cusp bucket plasma generator and tetrode accelerator with multi-slot apertures, is developed and tested for the Experimental Advanced Superconducting Tokamak neutral beam injector. Three ion sources are tested on the test bed with arc power of 80 kW, beam voltage of 80 keV, and beam power of 4 MW. The arc regulation technology with Langmuir probes is employed for the long pulse operation of ion source, and the long pulse beam of 50 keV @ 15.5 A @ 100 s and 80 keV @ 52A @ 1s are extracted, respectively.

  17. Design and Comparison of a 1 MW / 5s HTS SMES with Toroidal and Solenoidal Geometry

    E-Print Network [OSTI]

    Morandi, Antonio; Gholizad, Babak; Grilli, Francesco; Sirois, Frédéric; Zermeño, Víctor M R

    2015-01-01

    The design of a HTS SMES coil with solenoidal and toroidal geometry is carried out based on a commercially available 2G HTS conductor. A SMES system of practical interest (1 MW / 5 s) is considered. The comparison between ideal toroidal and solenoidal geometry is first discussed and the criteria used for choosing the geometrical parameters of the coils' bore are explained. The design of the real coil is then carried out and the final amount of conductor needed is compared. A preliminary comparison of the two coils in terms of AC loss during one charge discharge cycle is also discussed.

  18. Internal Technical Report, Safety Analysis Report 5 MW(e) Raft River Research and Development Plant

    SciTech Connect (OSTI)

    Brown, E.S.; Homer, G.B.; Shaber, C.R.; Thurow, T.L.

    1981-11-17

    The Raft River Geothermal Site is located in Southern Idaho's Raft River Valley, southwest of Malta, Idaho, in Cassia County. EG and G idaho, Inc., is the DOE's prime contractor for development of the Raft River geothermal field. Contract work has been progressing for several years towards creating a fully integrated utilization of geothermal water. Developmental progress has resulted in the drilling of seven major DOE wells. Four are producing geothermal water from reservoir temperatures measured to approximately 149 C (approximately 300 F). Closed-in well head pressures range from 69 to 102 kPa (100 to 175 psi). Two wells are scheduled for geothermal cold 60 C (140 F) water reinjection. The prime development effort is for a power plant designed to generate electricity using the heat from the geothermal hot water. The plant is designated as the ''5 MW(e) Raft River Research and Development Plant'' project. General site management assigned to EG and G has resulted in planning and development of many parts of the 5 MW program. Support and development activities have included: (1) engineering design, procurement, and construction support; (2) fluid supply and injection facilities, their study, and control; (3) development and installation of transfer piping systems for geothermal water collection and disposal by injection; and (4) heat exchanger fouling tests.

  19. Internal Technical Report, Safety Analysis Report 5 MW(e) Raft River Pilot Plant

    SciTech Connect (OSTI)

    Brown, E.S.; Homer, G.B.; Spencer, S.G.; Shaber, C.R.

    1980-05-30

    The Raft River Geothermal Site is located in Southern Idaho's Raft River Valley, southwest of Malta, Idaho, in Cassia County. EG and G idaho, Inc., is the DOE's prime contractor for development of the Raft River geothermal field. Contract work has been progressing for several years towards creating a fully integrated utilization of geothermal water. Developmental progress has resulted in the drilling of seven major DOE wells. Four are producing geothermal water from reservoir temperatures measured to approximately 149 C (approximately 300 F). Closed-in well head pressures range from 69 to 102 kPa (100 to 175 psi). Two wells are scheduled for geothermal cold 60 C (140 F) water reinjection. The prime development effort is for a power plant designed to generate electricity using the heat from the geothermal hot water. The plant is designated as the ''5 MW(e) Raft River Research and Development Plant'' project. General site management assigned to EG and G has resulted in planning and development of many parts of the 5 MW program. Support and development activities have included: (1) engineering design, procurement, and construction support; (2) fluid supply and injection facilities, their study, and control; (3) development and installation of transfer piping systems for geothermal water collection and disposal by injection; and (4) heat exchanger fouling tests.

  20. A 12 GHZ 50 MW Klystron for Support of Accelerator Research

    SciTech Connect (OSTI)

    Sprehn, Daryl; /SLAC; Haase, Andrew; /SLAC; Jensen, Aaron; /SLAC; Jongewaard, Erik; /SLAC; Nantista, Christopher; /SLAC; Vlieks, Arnold; /SLAC

    2011-05-31

    A 12 GHz 50MW X-band klystron is under development at the SLAC National Accelerator Laboratory Klystron Department. The klystron will be fabricated to support programs currently underway at three European Labs; CERN, PSI, and INFN Trieste. The choice of frequency selection was due to the CLIC RF frequency changing from 30 GHz to the European X-band frequency of 11.99 GHz in 2008. Since the Klystron Department currently builds 50MW klystrons at 11.424 GHz known collectively as the XL4 klystrons, it was deemed cost-effective to utilize many XL4 components by leaving the gun, electron beam transport, solenoid magnet and collector unchanged. To realize the rf parameters required, the rf cavities and rf output hardware were necessarily altered. Some improvements to the rf design have been made to reduce operating gradients and increase reliability. Changes in the multi-cell output structure, waveguide components, and the window will be discussed along with testing of the devices. Five klystrons known as XL5 klystrons are scheduled for production over the next two years.

  1. Design of the EURISOL multi-MW target assembly radiation and safety issues

    E-Print Network [OSTI]

    Felcini, Marta; Kadi, Yacine; Otto, Thomas; Tecchio, L

    2006-01-01

    The multi-MW target proposed for the EURISOL facility will be based on fission of uranium (or thorium) compounds to produce rare isotopes far from stability. A two-step process is used for the isotope production. First, neutrons are generated in a liquid mercury target, irradiated by the 1 GeV proton or deuteron beam, provided by the EURISOL linac driver. Then, the neutrons induce fission in a surrounding assembly of uranium carbide. R&D projects on several aspects of the target assembly are ongoing. Key criteria for the target design are a maximum beam power capability of 4 MW, a remote handling system with minimum downtime and maximum reliability, as well as radiation safety, minimization of hazards and the classification of the facility. In the framework of the ongoing radiation characterization and safety studies, radiation transport simulations have been performed to calculate the prompt radiation dose in the target and surrounding materials, as well as to determine shielding material and angle-depen...

  2. Design of the EURISOL multi-MW target assembly: radiation and safety issues

    E-Print Network [OSTI]

    Felcini, M; Kadi, Y; Otto, T; Tecchio, L; Otto, Th.

    2006-01-01

    The multi-MW target proposed for the EURISOL facility will be based on fission of uranium (or thorium) compounds to produce rare isotopes far from stability. A two-step process is used for the isotope production. First, neutrons are generated in a liquid mercury target, irradiated by the 1 GeV proton or deuteron beam, provided by the EURISOL linac driver. Then, the neutrons induce fission in a surrounding assembly of uranium carbide. R&D projects on several aspects of the target assembly are ongoing. Key criteria for the target design are a maximum beam power capability of 4 MW, a remote handling system with minimum downtime and maximum reliability, as well as radiation safety, minimization of hazards and the classification of the facility. In the framework of the ongoing radiation characterization and safety studies, radiation transport simulations have been performed to calculate the prompt radiation dose in the target and surrounding materials, as well as to determine shielding material and angle-depen...

  3. Voluntary Initiative: Partnering to Enhance Program Capacity...

    Energy Savers [EERE]

    Peer Exchange Call Series: Voluntary Initiative: Partnering to Enhance Program Capacity, Call Slides and Summary, May 8, 2014. Call Slides and Summary More Documents &...

  4. Increasing the Capacity of Existing Power Lines

    SciTech Connect (OSTI)

    2013-04-01

    The capacity of the grid has been largely unchanged for decades and needs to expand to accommodate new power plants and renewable energy projects.

  5. ,"Washington Natural Gas Underground Storage Capacity (MMcf)...

    U.S. Energy Information Administration (EIA) Indexed Site

    Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","Washington Natural Gas Underground Storage Capacity (MMcf)",1,"Annual",2014 ,"Release...

  6. Solar Energy and Capacity Value (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-09-01

    This is a one-page, two-sided fact sheet on the capacity of solar power to provide value to utilities and power system operators.

  7. ,"Texas Natural Gas Underground Storage Capacity (MMcf)"

    U.S. Energy Information Administration (EIA) Indexed Site

    ,"Worksheet Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","Texas Natural Gas Underground Storage Capacity (MMcf)",1,"Annual",2014 ,"Release Date:","9...

  8. Increasing water holding capacity for irrigation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Increasing water holding capacity for irrigation Reseachers recommend solutions for sediment trapping in irrigation system LANL and SNL leveraged technical expertise to determine...

  9. California: Conducting Polymer Binder Boosts Storage Capacity...

    Broader source: Energy.gov (indexed) [DOE]

    Nextval, Inc., Lawrence Berkeley National Laboratory (LBNL) developed a Conducting Polymer Binder for high-capacity lithium-ion batteries. With a focus on enabling smaller,...

  10. Low NO{sub x} combustion system with DSVS{trademark} rotating classifier retrofit for a 630 MW{sub e} cell burner unit

    SciTech Connect (OSTI)

    Bryk, S.A.; Maringo, G.J.; Shah, A.I. [Babcock and Wilcox, Barberton, OH (United States); Madden, V.F. [New England Power, Westborough, MA (United States)

    1996-12-31

    New England Power Company`s (NEP) 630 MW{sub e} Brayton Point Unit 3 is a universal pressure (UP) type supercritical boiler originally equipped with pulverized coal (PC) fired cell burners. In order to comply with the Phase 1 NO{sub x} emissions requirements under Title I of the 1990 Clean Air Act Amendments, the unit has been retrofitted with a low NO{sub x} staged combustion system during the spring 1995 outage. The unit was restarted in early May 1995 and was operating under the State Compliance emission levels by the end of the month. Additional optimization testing was performed in August, 1995. The retrofit scope consisted of replacing the cell burners with low NO{sub x} DRB-XCL{reg_sign} type PC/oil burners and overfire air ports within the existing open windbox, with no change in the firing pattern. A 70% NO{sub x} reduction from baseline levels was achieved while maintaining acceptable unburned carbon (UBC) and carbon monoxide (CO) emission levels. To maintain low UBC levels, the scope included modifying the MPS-89 pulverizers by replacing the existing stationary classifiers with the B and W DSVS{trademark} (Dynamically Staged Variable Speed) two stage rotating classifiers. The DSVS{trademark} classifiers provide higher fineness for UBC control without derating the mill capacity. This paper will describe the project and discuss the retrofit emissions data. The paper will conclude with recommendations for retrofitting other similarly designed units.

  11. Analysis of Plug Load Capacities and Power Requirements in Commercial Buildings: Preprint

    SciTech Connect (OSTI)

    Sheppy, M.; Torcellini, P.; Gentile-Polese, L.

    2014-08-01

    Plug and process load power requirements are frequently overestimated because designers often use estimates based on 'nameplate' data, or design assumptions are high because information is not available. This generally results in oversized heating, ventilation, and air-conditioning systems; increased initial construction costs; and increased energy use caused by inefficiencies at low, part-load operation. Rightsizing of chillers in two buildings reduced whole-building energy use by 3%-4%. If an integrated design approach could enable 3% whole-building energy savings in all U.S. office buildings stock, it could save 34 TBtu of site energy per year.

  12. North Dakota Refining Capacity Study

    SciTech Connect (OSTI)

    Dennis Hill; Kurt Swenson; Carl Tuura; Jim Simon; Robert Vermette; Gilberto Marcha; Steve Kelly; David Wells; Ed Palmer; Kuo Yu; Tram Nguyen; Juliam Migliavacca

    2011-01-05

    According to a 2008 report issued by the United States Geological Survey, North Dakota and Montana have an estimated 3.0 to 4.3 billion barrels of undiscovered, technically recoverable oil in an area known as the Bakken Formation. With the size and remoteness of the discovery, the question became 'can a business case be made for increasing refining capacity in North Dakota?' And, if so what is the impact to existing players in the region. To answer the question, a study committee comprised of leaders in the region's petroleum industry were brought together to define the scope of the study, hire a consulting firm and oversee the study. The study committee met frequently to provide input on the findings and modify the course of the study, as needed. The study concluded that the Petroleum Area Defense District II (PADD II) has an oversupply of gasoline. With that in mind, a niche market, naphtha, was identified. Naphtha is used as a diluent used for pipelining the bitumen (heavy crude) from Canada to crude markets. The study predicted there will continue to be an increase in the demand for naphtha through 2030. The study estimated the optimal configuration for the refinery at 34,000 barrels per day (BPD) producing 15,000 BPD of naphtha and a 52 percent refinery charge for jet and diesel yield. The financial modeling assumed the sponsor of a refinery would invest its own capital to pay for construction costs. With this assumption, the internal rate of return is 9.2 percent which is not sufficient to attract traditional investment given the risk factor of the project. With that in mind, those interested in pursuing this niche market will need to identify incentives to improve the rate of return.

  13. Development of a 10 MW Sheet Beam Klystron for the ILC

    SciTech Connect (OSTI)

    Sprehn, D.; Jongewaard, E.; Haase, A.; Jensen, A.; Martin, D.; /SLAC; Burke, A.; /SAIC, Sunnyvale

    2009-05-07

    SLAC is developing a 10 MW, 5 Hz, 1.6 ms, L-band (1.3 GHz) Sheet-Beam Klystron as a less expensive and more compact alternative to the ILC baseline Multiple-Beam Klystron. The Klystron is intended as a plug-compatible device of the same beam current and operating voltage as existing Multiple-Beam Klystrons. At this time, a beam tester has been constructed and currently is in test. The beam tester includes an intercepting cup for making beam quality measurements of the 130 A, 40-to-1 aspect ratio beam. Measurements will be made of the electrostatic beam and of the beam after transporting through a drift tube and magnetic focusing system. General theory of operation, design trade-offs, and manufacturing considerations of both the beam tester and klystron will be discussed.

  14. The long-pulse, high-current relativistic klystron at 500 MW and beyond

    SciTech Connect (OSTI)

    Fazio, M.V.; Haynes, W.B.; Carlsten, B.E.; Stringfield, R.M.

    1994-10-01

    This paper describes the development of an L-band annular beam, high-current relativistic klystron for producing a peak power of 1 GW at a pulse length of 1 {mu}s. The tube consists of three cavities: the input cavity driven by a 300 kW magnetron, an idler cavity, and an output cavity. The tube has produced 475 MW and an energy per pulse of 160 J. The microwave output pulse terminates prematurely, before the peak power in the electron beam pulse is reached. The pulse shortening is believed to be caused by too high a voltage across the gap of the output cavity. The result is electron reflection in the output gap leading to beam disruption and high voltage breakdown across the gap. Current experimental results are presented with an emphasis on the design of output cavities for coupling microwave power from high current, very low impedance modulated electron beams.

  15. Final Report, Validation of Novel Planar Cell Design for MW-Scale SOFC Power Systems

    SciTech Connect (OSTI)

    Swartz, Dr Scott L.; Thrun, Dr Lora B.; Arkenberg, Mr Gene B.; Chenault, Ms Kellie M.

    2012-01-03

    This report describes the work completed by NexTech Materials, Ltd. during a three-year project to validate an electrolyte-supported planar solid oxide fuel cell design, termed the FlexCell, for coal-based, megawatt-scale power generation systems. This project was focused on the fabrication and testing of electrolyte-supported FlexCells with yttria-stabilized zirconia (YSZ) as the electrolyte material. YSZ based FlexCells were made with sizes ranging from 100 to 500 cm2. Single-cell testing was performed to confirm high electrochemical performance, both with diluted hydrogen and simulated coal gas as fuels. Finite element analysis modeling was performed at The Ohio State University was performed to establish FlexCell architectures with optimum mechanical robustness. A manufacturing cost analysis was completed, which confirmed that manufacturing costs of less than $50/kW are achievable at high volumes (500 MW/year).

  16. Validation of Novel Planar Cell Design for MW-Scale SOFC Power Systems

    SciTech Connect (OSTI)

    Scott Swartz; Lora Thrun; Gene Arkenberg; Kellie Chenault

    2011-09-30

    This report describes the work completed by NexTech Materials, Ltd. during a three-year project to validate an electrolyte-supported planar solid oxide fuel cell design, termed the FlexCell, for coal-based, megawatt-scale power generation systems. This project was focused on the fabrication and testing of electrolyte-supported FlexCells with yttria-stabilized zirconia (YSZ) as the electrolyte material. YSZ based FlexCells were made with sizes ranging from 100 to 500 cm{sup 2}. Single-cell testing was performed to confirm high electrochemical performance, both with diluted hydrogen and simulated coal gas as fuels. Finite element analysis modeling was performed at The Ohio State University was performed to establish FlexCell architectures with optimum mechanical robustness. A manufacturing cost analysis was completed, which confirmed that manufacturing costs of less than $50/kW are achievable at high volumes (500 MW/year). DISCLAIMER

  17. Definition of a 5MW/61.5m wind turbine blade reference model.

    SciTech Connect (OSTI)

    Resor, Brian Ray

    2013-04-01

    A basic structural concept of the blade design that is associated with the frequently utilized %E2%80%9CNREL offshore 5-MW baseline wind turbine%E2%80%9D is needed for studies involving blade structural design and blade structural design tools. The blade structural design documented in this report represents a concept that meets basic design criteria set forth by IEC standards for the onshore turbine. The design documented in this report is not a fully vetted blade design which is ready for manufacture. The intent of the structural concept described by this report is to provide a good starting point for more detailed and targeted investigations such as blade design optimization, blade design tool verification, blade materials and structures investigations, and blade design standards evaluation. This report documents the information used to create the current model as well as the analyses used to verify that the blade structural performance meets reasonable blade design criteria.

  18. NREL Establishes a 1.5-MW Wind Turbine Test Platform for Research Partnerships (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-03-01

    Research turbine supports sustained technology development. For more than three decades, engineers at the National Renewable Energy Laboratory's (NREL) National Wind Technology Center (NWTC) have worked with the U.S. Department of Energy (DOE) Wind Program and industry partners to advance wind energy technology, improve wind turbine performance, and reduce the cost of energy. Although there have been dramatic increases in performance and drops in the cost of wind energy-from $0.80 per kilowatt-hour to between $0.06 and $0.08 per kilowatt-hour-the goal of the DOE Wind Program is to further increase performance and reduce the cost of energy for land-based systems so that wind energy can compete with natural gas by 2020. In support of the program's research and development (R and D) efforts, NREL has constructed state-of-the-art facilities at the NWTC where industry partners, universities, and other DOE laboratories can conduct tests and experiments to further advance wind technology. The latest facility to come online is the DOE-GE 1.5-MW wind turbine test platform. Working with DOE, NREL purchased and installed a GE 1.5-MW wind turbine at the NWTC in 2009. Since then, NREL engineers have extensively instrumented the machine, conducted power performance and full-system modal tests, and collected structural loads measurements to obtain baseline characterization of the turbine's power curve, vibration characteristics, and fatigue loads in the uniquely challenging NWTC inflow environment. By successfully completing a baseline for the turbine's performance and structural response, NREL engineers have established a test platform that can be used by industry, university, and DOE laboratory researchers to test wind turbine control systems and components. The new test platform will also enable researchers to acquire the measurements needed to develop and validate wind turbine models and improve design codes.

  19. Managing Capacity For Telecommunications Networks Under Uncertainty

    E-Print Network [OSTI]

    Forsyth, Peter A.

    the underlying risk factor in the bandwidth market, and then apply real options theory to the upgrade decision, this real options approach has not been used pre- viously in the area of network capacity planning--uncertain demand for capacity, real options, net- work planning I. INTRODUCTION In the past, bandwidth was traded

  20. REDUCTION CAPACITY OF SALTSTONE AND SALTSTONE COMPONENTS

    SciTech Connect (OSTI)

    Roberts, K.; Kaplan, D.

    2009-11-30

    The duration that saltstone retains its ability to immobilize some key radionuclides, such as technetium (Tc), plutonium (Pu), and neptunium (Np), depends on its capacity to maintain a low redox status (or low oxidation state). The reduction capacity is a measure of the mass of reductants present in the saltstone; the reductants are the active ingredients that immobilize Tc, Pu, and Np. Once reductants are exhausted, the saltstone loses its ability to immobilize these radionuclides. The reduction capacity values reported here are based on the Ce(IV)/Fe(II) system. The Portland cement (198 {micro}eq/g) and especially the fly ash (299 {micro}eq/g) had a measurable amount of reduction capacity, but the blast furnace slag (820 {micro}eq/g) not surprisingly accounted for most of the reduction capacity. The blast furnace slag contains ferrous iron and sulfides which are strong reducing and precipitating species for a large number of solids. Three saltstone samples containing 45% slag or one sample containing 90% slag had essentially the same reduction capacity as pure slag. There appears to be some critical concentration between 10% and 45% slag in the Saltstone formulation that is needed to create the maximum reduction capacity. Values from this work supported those previously reported, namely that the reduction capacity of SRS saltstone is about 820 {micro}eq/g; this value is recommended for estimating the longevity that the Saltstone Disposal Facility will retain its ability to immobilize radionuclides.

  1. PREPARING THE HIGH FLUX ISOTOPE REACTOR FOR CONVERSION TO LOW ENRICHED URANIUM FUEL ? RETURN TO 100 MW

    SciTech Connect (OSTI)

    Smith, Kevin Arthur [ORNL; Primm, Trent [ORNL

    2009-01-01

    The feasibility of low-enriched uranium (LEU) fuel as a replacement for the current, high enriched uranium (HEU) fuel for the High Flux Isotope Reactor (HFIR) has been under study since 2006. Reactor performance studies have been completed for conceptual plate designs and show that maintaining reactor performance while converting to LEU fuel requires returning the reactor power to 100 MW from 85 MW. The analyses required to up-rate the reactor power and the methods to perform these analyses are discussed. Comments regarding the regulatory approval process are provided along with a conceptual schedule.

  2. Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1000 Megawatts (MW) of New Wind Power in Maine

    SciTech Connect (OSTI)

    2008-10-01

    Analysis of the expected impacts of 1000 MW of wind power in Maine, including economic benefits, CO2 emissions reductions, and water conservation.

  3. Proposal for the award of a contract for the supply of four X-band klystrons of 6 MW peak power including modulators

    E-Print Network [OSTI]

    2013-01-01

    Proposal for the award of a contract for the supply of four X-band klystrons of 6 MW peak power including modulators

  4. Representation of the Solar Capacity Value in the ReEDS Capacity Expansion Model: Preprint

    SciTech Connect (OSTI)

    Sigrin, B.; Sullivan, P.; Ibanez, E.; Margolis, R.

    2014-08-01

    An important emerging issue is the estimation of renewables' contributions to reliably meeting system demand, or their capacity value. While the capacity value of thermal generation can be estimated easily, assessment of wind and solar requires a more nuanced approach due to resource variability. Reliability-based methods, particularly, effective load-carrying capacity (ELCC), are considered to be the most robust techniques for addressing this resource variability. The Regional Energy Deployment System (ReEDS) capacity expansion model and other long-term electricity capacity planning models require an approach to estimating CV for generalized PV and system configurations with low computational and data requirements. In this paper we validate treatment of solar photovoltaic (PV) capacity value by ReEDS capacity expansion model by comparing model results to literature for a range of energy penetration levels. Results from the ReEDS model are found to compare well with both comparisons--despite not being resolved at an hourly scale.

  5. Yolo County, California, made history in July when officials installed a 1 MW solar photovoltaic (PV) project to supply power

    E-Print Network [OSTI]

    Yolo County, California, made history in July when officials installed a 1 MW solar photovoltaic Reinvestment and Recovery Act (ARRA) of 2009 extended QECB funding by $3.2 billion and provided $2.4 billion in funding for new CREBs. Note that CREBs have been fully allocated and are not currently available. While

  6. --H.U. Lemke, M.W. Vannier, Inamura, A.G. Farman, & J.H.C. Reiber (Editors)

    E-Print Network [OSTI]

    Wahle, Andreas

    CARS -- H.U. Lemke, M.W. Vannier, Inamura, A.G. Farman, & J.H.C. Reiber (Editors) CARS­Gen Lai d , Krishnan Chandran b Milan Sonka a University Iowa, Department Electrical Computer Engineering curvature reliably separates images originating from different heart phases. fusionCARS -- H.U. Lemke, M

  7. Gas Spring Losses in Linear Clearance Seal Compressors P.B. Bailey, M.W. Dadd, J.S. Reed*

    E-Print Network [OSTI]

    1 Gas Spring Losses in Linear Clearance Seal Compressors P.B. Bailey, M.W. Dadd, J.S. Reed* , C, and the simplest demonstration of this can be observed in a gas spring. Our understanding of these gas spring with a clearance seal linear compressor attached to a plain gas spring volume. The static flow through

  8. BEAM-POWER DEPOSITION IN A 4-MW TARGET STATION FOR A MUON COLLIDER OR A NEUTRINO FACTORY

    E-Print Network [OSTI]

    McDonald, Kirk

    BEAM-POWER DEPOSITION IN A 4-MW TARGET STATION FOR A MUON COLLIDER OR A NEUTRINO FACTORY N of simulated power deposition in a y-z (vertical) section of the target station is shown in Fig. 2, and some, Coventry CV4 7AL, UK Abstract We present the results of power deposition in various components

  9. BEAM-POWER DEPOSITION IN A 4-MW TARGET STATION FOR A MUON COLLIDER OR A NEUTRINO FACTORY

    E-Print Network [OSTI]

    McDonald, Kirk

    BEAM-POWER DEPOSITION IN A 4-MW TARGET STATION FOR A MUON COLLIDER OR A NEUTRINO FACTORY (IPAC11 with shielding out to 1.2 m radius. W-C shielding likely needed beyond the target station, where ~ 800 kW power-carbide + water shielding of superconducting magnets for the target station at a Muon Collider or Neutrino Factory

  10. PSY/WGS 506 Psychology of Gender Spring 2013, MW 4:307:15, 736 Poe Hall

    E-Print Network [OSTI]

    Kaber, David B.

    PSY/WGS 506 ­ Psychology of Gender Spring 2013, MW 4:307:15, 736 Poe Hall Dr. Mary Wyer Poe 732 relations from a psychological perspective. The course focuses on cultural meanings attached to being readings and class discussions. 3. Applying critical thinking skills and a psychological perspective

  11. Observation and Study of Low-Frequency Oscillations in a 1.5-MW 110-GHz Gyrotron

    E-Print Network [OSTI]

    Cerfon, Antoine J.

    We report the observation of low-frequency oscillations (LFOs) in the range 165-180 MHz in a 1.5-MW 110-GHz gyrotron operating in 3-mus pulses. The oscillations have been measured by a capacitive probe located just before ...

  12. Single-transverse-mode near-IR superluminescent diodes with cw output power up to 100 mW

    SciTech Connect (OSTI)

    Andreeva, E V; Il'chenko, S N; Kostin, Yu O [Superlum Diodes Ltd., Moscow (Russian Federation); Yakubovich, S D [Moscow State Institute of Radio-Engineering, Electronics and Automation (Technical University), Moscow (Russian Federation)

    2014-10-29

    A series of light-emitting modules based on single-mode quantum-well superluminescent diodes with centre emission wavelengths of about 790, 840, 960 and 1060 nm and a cw output power up to 100 mW in free space is developed. A sufficiently long service life of these devices is demonstrated. (lasers)

  13. Economic Impact Analysis of CPV Towantic, LLC's Construction and Operation of an 805 MW Electricity Generation Facility in Oxford, CT

    E-Print Network [OSTI]

    Alpay, S. Pamir

    Economic Impact Analysis of CPV Towantic, LLC's Construction and Operation of an 805 MW, 2015 #12;Connecticut Center for Economic Analysis Page 2 of 25 University of Connecticut EXECUTIVE SUMMARY CPV Towantic, LLC (CPV) engaged the Connecticut Center for Economic Analysis (CCEA) to develop

  14. Feasible experimental study on the utilization of a 300 MW CFB boiler desulfurizating bottom ash for construction applications

    SciTech Connect (OSTI)

    Lu, X.F.; Amano, R.S. [University of Wisconsin, Milwaukee, WI (United States). Dept. of Mechanical Engineering

    2006-12-15

    CFB boiler ash cannot be used as a cement replacement in concrete due to its unacceptably high sulfur content. The disposal in landfills has been the most common means of handling ash in circulating fluidized bed boiler power plants. However for a 300 MW CFB boiler power plant, there will be 600,000 tons of ash discharged per year and will result in great volumes and disposal cost of ash byproduct. It was very necessary to solve the utilization of CFB ash and to decrease the disposal cost of CFB ash. The feasible experimental study results on the utilization of the bottom ashes of a 300 MW CFB boiler in Baima power plant in China were reported in this paper. The bottom ashes used for test came from the discharged bottom ashes in a 100 MW CFB boiler in which the anthracite and limestone designed for the 300 MW CFB project was burned. The results of this study showed that the bottom ash could be used for cementitious material, road concrete, and road base material. The masonry cements, road concrete with 30 MPa compressive strength and 4.0 MPa flexural strength, and the road base material used for base courses of the expressway, the main road and the minor lane were all prepared with milled CFB bottom ashes in the lab. The better methods of utilization of the bottom ashes were discussed in this paper.

  15. Capacity Building Project with Howard University

    Broader source: Energy.gov [DOE]

    The purpose of this initiative is to build community capacity for public participation in environmental and energy decision making. The target communities are those impacted by U.S. Department of...

  16. World crude capacity, conversion capability inch upward

    SciTech Connect (OSTI)

    Rhodes, A.K.

    1994-12-19

    Reported world crude capacity increased almost 1 million b/d, while conversion processes--fluid catalytic cracking (FCC), hydrocracking, coking--increased more than 1.7 million b/d or 8.3%, according to the Journal's most recent survey of world refining capacity. As a measure of capacity growth in the past year, changes in distillation capacities (atmospheric plus vacuum) were calculated for three major refining regions. The year-to-year comparison indicates: for the US, an increase of 293,000 b/d, or 1.3%; for the European Economic Community (E.E.C.), an increase of 431,000 b/d, or 2.6%; and for Asia/Pacific, excluding China, an increase of 122,000 b/d, or 1.1%. In addition to the compiled data the paper describes the survey layout, regional changes, conversion units, hydroprocessing, company size, oxygenates, and construction.

  17. Tripling the capacity of wireless communications using

    E-Print Network [OSTI]

    channels of electric-®eld polarization for wireless communication. In order to make our statements more................................................................. Tripling the capacity of wireless .............................................................................................................................................. Wireless communications are a fundamental part of modern information infrastructure. But wireless bandwidth

  18. Capacities of linear quantum optical systems

    E-Print Network [OSTI]

    Lloyd, Seth

    A wide variety of communication channels employ the quantized electromagnetic field to convey information. Their communication capacity crucially depends on losses associated to spatial characteristics of the channel such ...

  19. National Decentralized Water Resources Capacity Development Project

    E-Print Network [OSTI]

    Gold, Art

    National Decentralized Water Resources Capacity Development Project Mapping Onsite Treatment Needs Onsite Treatment Needs, Pollution Risks, and Management Options Using GIS Submitted by the University. Wastewater Planning Handbook: Mapping Onsite Treatment Needs, Pollution Risks, and Management Options Using

  20. Measuring the capacity impacts of demand response

    SciTech Connect (OSTI)

    Earle, Robert; Kahn, Edward P.; Macan, Edo

    2009-07-15

    Critical peak pricing and peak time rebate programs offer benefits by increasing system reliability, and therefore, reducing capacity needs of the electric power system. These benefits, however, decrease substantially as the size of the programs grows relative to the system size. More flexible schemes for deployment of demand response can help address the decreasing returns to scale in capacity value, but more flexible demand response has decreasing returns to scale as well. (author)

  1. Modern Wireless Network Design Based on Constrained Capacity

    E-Print Network [OSTI]

    Valenti, Matthew C.

    The capacity in this channel is: ­ where Eb is the energy per (information) bit. This capacity is achievedModern Wireless Network Design Based on Constrained Capacity April 20, 2005 Matthew Valenti Wireless Network Design Based on Constrained Capacity 2/37 Overview Key observations: ­ Capacity

  2. Rehabilitation of a 410-MW utility boiler at Costa Sur, Puerto Rico

    SciTech Connect (OSTI)

    Rosado, R.; Salmeron, M.

    1995-12-31

    To increase unit reliability and availability and to meet the current and future electric power demands in Puerto Rico, the Puerto Rico Electric Power Authority (PREPA) recently performed a scheduled outage rehabilitation of Costa Sur Power Station Unit 5. This major rehabilitation of a 23-year-old, 410 MW, oil-fired boiler was accompanied by the upgrading of the low-pressure turbine with new rotors. The boiler rehabilitation included the replacement of all waterwall floor panels from just below the burner windbox, down to the lower drum. Temporary support was provided for the lower drum and its structural system during the panel replacement. The steam drum internals were completely rehabilitated, with the installation of a new liner and cleaning and repair of other internals as required. The superheater and reheater desuperheater liners were also replaced. In addition, all major components of both the firing system and the air preheaters were replaced. The gas recirculation fan was rehabilitated, and its discharge duct was replaced.

  3. A 200 MHz 35 MW Multiple Beam Klystron for Accelerator Applications Final Report

    SciTech Connect (OSTI)

    R. Lawrence Ives; Michael Read; Patrick Ferguson; David Marsden

    2011-11-28

    Calabazas Creek Research, Inc. (CCR) performed initial development of a compact and reliable 35 MW, multiple beam klystron (MBK) at 200 MHz with a pulse length of 0.125 ms and a 30 Hz repetition rate. The device was targeted for acceleration and ionization cooling of a muon collider, but there are several other potential applications in this frequency range. The klystron uses multiple beams propagating in individual beam tunnels to reduce space charge and allow reduction in the accelerating voltage. This allows a significant reduction in length over a single beam source. More importantly this allows more efficient and less expensive power supplies. At 200 MHz, the interaction circuit for a single beam klystron would be more than six meters long to obtain 50% efficiency and 50 dB gain. This would require a beam voltage of approximately 400 kV and current of 251 A for a microperveance of 1.0. For an eight beam MBK with the same beam perveance, a three meter long interaction circuit achieves the same power and gain. Each beam operates at 142 kV and 70A. The Phase I demonstrated that this device could be fabricated with funding available in a Phase II program and could achieve the program specifications.

  4. Recent Performance and Ignition Tests of the pulsed SNS H- Source for 1-MW Neutron Production

    SciTech Connect (OSTI)

    Stockli, Martin P [ORNL; Han, Baoxi [ORNL; Murray Jr, S N [ORNL; Pennisi, Terry R [ORNL; Piller, Chip [ORNL; Santana, Manuel [ORNL; Welton, Robert F [ORNL

    2015-01-01

    After acquiring several reliable spare targets, SNS ramped the beam power from 850 kW to 1.4 MW, which required an increase in H- beam pulse length from 0.88 to 1.0 ms at 60 Hz. This increase initially produced slow 2-MHz power ramp-ups and, after several weeks of uninterrupted operation, it produced plasma outages every time the pulse length was raised above ~0.95 ms. Similar outages were previously observed towards the end of long service cycles, which were believed to indicate that the breakdown voltage of the high purity hydrogen started to exceed the induced electric fields. In 2011 the RF was reconfigured to start with 10 cycles of 1.96 MHz, which yielded the shortest H- beam rise times and apparently eliminated those plasma outages. The new, pulse-length dependent outages were eliminated by increasing the initial frequency to 1.985 MHz. However, careful frequency studies are unable to justify this frequency. In addition, the paper discusses the issues and solutions for the electron-dump voltage, which starts to sag and become unstable after several weeks of high current operation.

  5. Cascading elastic perturbation in Japan due to the 2012 Mw 8.6 Indian Ocean Earthquake

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Delorey, A. A.; Johnson, P. A.; Chao, K.; Obara, K.

    2015-10-02

    Since the discovery of extensive earthquake triggering occurring in response to the 1992 Mw 7.3 Landers earthquake, it is now well established that seismic waves from earthquakes can trigger other earthquakes, tremor, slow slip, and pore pressure changes. Our contention is that earthquake triggering is one manifestation of a more widespread elastic disturbance that reveals information about Earth’s stress state. Earth’s stress state is central to our understanding of both natural and anthropogenic-induced crustal processes. Here we present that seismic waves from distant earthquakes may perturb stresses and frictional properties on faults and elastic moduli of the crust in cascadingmore »fashion. Transient dynamic stresses place crustal material into a metastable state during which material recovers through a process termed slow dynamics. This observation of widespread, dynamically induced elastic perturbation, including systematic migration of offshore seismicity, strain transients, and velocity transients, presents a new characterization of Earth’s elastic system that will advance our understanding of plate tectonics, seismicity, and seismic hazards.« less

  6. Final Report 200 MW L-Band Annular Beam Klystron for Accelerators

    SciTech Connect (OSTI)

    Read, Michael; Ferguson, Patrick; Ives, Lawrence; Song, Liqun; Carlsten, Bruce; Fazio, Michael

    2009-02-11

    This program developed a 200 MW, 1.3 GHz, Annular Beam Klystron (ABK) for accelerator systems. An ABK provides lower impedance than a conventional klystron, making it possible to produce higher RF powers with lower voltages. With a higher power per unit, fewer klystrons would be required for a large accelerator. Lower voltage also simplifies and reduces the cost of the power supply system. Both features will significantly lower the cost of an RF system. This device operates at 475 kV. The klystron uses a magnetron injection gun producing 1100 A in one microsecond pulses. Power is extracted into fundamental rectangular waveguide through two output windows. The predicted gain is approximately 45 dB with estimated efficiency of 45%. The klystron was assembled, but no facility was available for testing. Consequently, no high power performance measurements are available. Because the assembled klystron is approximately 15 feet long, it was disassembled for storage. It can be reassembled should a use materialize.

  7. System Modeling of ORNL s 20 MW(t) Wood-fired Gasifying Boiler

    SciTech Connect (OSTI)

    Daw, C Stuart [ORNL; FINNEY, Charles E A [ORNL; Wiggins, Gavin [ORNL; Hao, Ye [ORNL

    2010-01-01

    We present an overview of the new 20 MW(t) wood-fired steam plant currently under construction by Johnson Controls, Inc. at the Oak Ridge National Laboratory in Tennessee. The new plant will utilize a low-temperature air-blown gasifier system developed by the Nexterra Systems Corporation to generate low-heating value syngas (producer gas), which will then be burned in a staged combustion chamber to produce heat for the boiler. This is considered a showcase project for demonstrating the benefits of clean, bio-based energy, and thus there is considerable interest in monitoring and modeling the energy efficiency and environmental footprint of this technology relative to conventional steam generation with petroleum-based fuels. In preparation for system startup in 2012, we are developing steady-state and dynamic models of the major process components, including the gasifiers and combustor. These tools are intended to assist in tracking and optimizing system performance and for carrying out future conceptual studies of process changes that might improve the overall energy efficiency and sustainability. In this paper we describe the status of our steady-state gasifier and combustor models and illustrate preliminary results from limited parametric studies.

  8. JOURNAL OF GEOPHYSICAL RESEARCH: SOLID EARTH, VOL. 118, 119, doi:10.1002/jgrb.50117, 2013 The 2011 Mw 7.1 Van (Eastern Turkey) earthquake

    E-Print Network [OSTI]

    Elliott, John

    Mw 7.1 Van (Eastern Turkey) earthquake J. R. Elliott,1 A. C. Copley,2 R. Holley,3 K. Scharer,4 and B to constrain the fault parameters of the Mw 7.1 2011 Van (Eastern Turkey) reverse-slip earthquake Turkey) earthquake, J. Geophys. Res. Solid Earth, 118, doi:10.1002/jgrb.50117. 1. Introduction [2

  9. JOURNAL OF GEOPHYSICAL RESEARCH: SOLID EARTH, VOL. 118, 16191637, doi:10.1002/jgrb.50117, 2013 The 2011 Mw 7.1 Van (Eastern Turkey) earthquake

    E-Print Network [OSTI]

    Cambridge, University of

    The 2011 Mw 7.1 Van (Eastern Turkey) earthquake J. R. Elliott,1 A. C. Copley,2 R. Holley,3 K. Scharer,4 imagery, and field observations to constrain the fault parameters of the Mw 7.1 2011 Van (Eastern Turkey (Eastern Turkey) earthquake, J. Geophys. Res. Solid Earth, 118, 1619­1637, doi:10.1002/jgrb.50117. 1

  10. Table 2. Ten Largest Plants by Generation Capacity, 2013

    U.S. Energy Information Administration (EIA) Indexed Site

    (MW)" 1,"Chalk Point LLC","Petroleum","NRG Chalk Point LLC",2248 2,"Calvert Cliffs Nuclear Power Plant","Nuclear","Calvert Cliffs Nuclear PP LLC",1716 3,"Morgantown Generating...

  11. Proposed changes to generating capacity 1980-1989 for the contiguous United States: as projected by the Regional Electric Reliability Councils in their April 1, 1980 long-range coordinated planning reports to the Department of Energy

    SciTech Connect (OSTI)

    1980-12-01

    The changes in generating capacity projected for 1980 to 1989 are summarized. Tabulated data provide summaries to the information on projected generating unit construction, retirements, and changes, in several different categories and groupings. The new generating units to be completed by the end of 1989 total 699, representing 259,490 megawatts. This total includes 10 wind power and one fuel cell installations totaling 48.5 MW to be completed by the end of 1989. There are 321 units totaling 13,222 MW to be retired. There are capacity changes due to upratings and deratings. Summary data are presented for: total requirement for electric energy generation for 1985; hydroelectric energy production for 1985; nuclear energy production for 1985; geothermal and other energy production for 1985; approximate non-fossil generation for 1985; range of fossil energy requirements for 1985; actual fossil energy sources 1974 to 1979; estimated range of fossil fuel requirements for 1985; coal capacity available in 1985; and computation of fuel use in 1985. Power plant capacity factors are presented. Extensive data on proposed generating capacity changes by individual units in the 9 Regional Electric Reliability Councils are presented.

  12. Optimizing Geographic Allotment of Photovoltaic Capacity in a Distributed Generation Setting: Preprint

    SciTech Connect (OSTI)

    Urquhart, B.; Sengupta, M.; Keller, J.

    2012-09-01

    A multi-objective optimization was performed to allocate 2MW of PV among four candidate sites on the island of Lanai such that energy was maximized and variability in the form of ramp rates was minimized. This resulted in an optimal solution set which provides a range of geographic allotment alternatives for the fixed PV capacity. Within the optimal set, a tradeoff between energy produced and variability experienced was found, whereby a decrease in variability always necessitates a simultaneous decrease in energy. A design point within the optimal set was selected for study which decreased extreme ramp rates by over 50% while only decreasing annual energy generation by 3% over the maximum generation allocation. To quantify the allotment mix selected, a metric was developed, called the ramp ratio, which compares ramping magnitude when all capacity is allotted to a single location to the aggregate ramping magnitude in a distributed scenario. The ramp ratio quantifies simultaneously how much smoothing a distributed scenario would experience over single site allotment and how much a single site is being under-utilized for its ability to reduce aggregate variability. This paper creates a framework for use by cities and municipal utilities to reduce variability impacts while planning for high penetration of PV on the distribution grid.

  13. Thermal-hydraulic analysis of the LANL/IPPE/EDO-GP 1-MW LBE target

    SciTech Connect (OSTI)

    He, X.; Ammerman, C.; Woloshun, K.; Li, N.

    2000-07-01

    The accelerator-driven transmutation of waste (ATW) concept has been proposed by the United States and other countries to transmute plutonium, higher actinides, and other environmentally hazardous fission products. One of the key components in the ATW concept is a target that, via spallation, produces neutrons to transmute nuclear waste. Since significant heat is generated during fissioning of the waste actinides, an efficient heat removal system is necessary. Liquid lead-bismuth eutectic (LBE) is an efficient coolant as well as a good spallation target for production of neutrons. The LBE coolant technology has been successfully used in Russian submarine nuclear reactors. The International Science and Technology Center (ISTC) has funded the Institute of Physics and Power Engineering (IPPE) and the Experiment and Design Organization-Gidropress (EDO-GP) of Russia to design and manufacture a pilot target (Target Circuit One-TC1) that incorporates Russian LBE technology into the ATW concept. The target will be tested in the 800-MeV, 1-mA proton beam at the Los Alamos National Laboratory (LANL) in 2 yr. These target experiments will provide valuable information on the performance of LBE as both spallation target and coolant. They will also help to design target/blanket systems for future ATW facilities. In summary, the authors have carried out thermal-hydraulic analyses for the LANL/IPPE/EDO-GP 1-MW LBE target. It is shown that the current design is suitable for the beam-on tests. The diffuser plate successfully enhances the coolant flow around the window center but still avoids generating recirculation zone downstream. The temperature range is within the proper operation range for both the LBE coolant and the structural materials.

  14. Development of high-capacity cathode materials with integrated...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    high-capacity cathode materials with integrated structures Development of high-capacity cathode materials with integrated structures 2009 DOE Hydrogen Program and Vehicle...

  15. Development of High-Capacity Cathode Materials with Integrated...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    & Publications Development of High-Capacity Cathode Materials with Integrated Structures Development of High-Capacity Cathode Materials with Integrated Structures...

  16. Development of High-Capacity Cathode Materials with Integrated...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    & Publications Development of high-capacity cathode materials with integrated structures Development of High-Capacity Cathode Materials with Integrated Structures...

  17. Ukraine-Enhancing Capacity for Low Emission Development Strategies...

    Open Energy Info (EERE)

    Ukraine-Enhancing Capacity for Low Emission Development Strategies (EC-LEDS) Jump to: navigation, search Name Ukraine-Enhancing Capacity for Low Emission Development Strategies...

  18. Mexico-Enhancing Capacity for Low Emission Development Strategies...

    Open Energy Info (EERE)

    Mexico-Enhancing Capacity for Low Emission Development Strategies (EC-LEDS) Jump to: navigation, search Name Mexico-Enhancing Capacity for Low Emission Development Strategies...

  19. Study Finds 54 Gigawatts of Offshore Wind Capacity Technically...

    Energy Savers [EERE]

    Study Finds 54 Gigawatts of Offshore Wind Capacity Technically Possible by 2030 Study Finds 54 Gigawatts of Offshore Wind Capacity Technically Possible by 2030 September 11, 2014 -...

  20. Modeling-Thermo-electrochemistry, Capacity Degradation and Mechanics...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Modeling-Thermo-electrochemistry, Capacity Degradation and Mechanics with SEI Layer Modeling-Thermo-electrochemistry, Capacity Degradation and Mechanics with SEI Layer 2011 DOE...

  1. DOE Receives Responses on the Implementation of Large-Capacity...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Large-Capacity Clothes Washer Waivers DOE Issues Enforcement Guidance on Large-Capacity Clothes Washer Waivers and the Waiver Process Electrolux Gibson Air Conditioner...

  2. India-Vulnerability Assessment and Enhancing Adaptive Capacities...

    Open Energy Info (EERE)

    India-Vulnerability Assessment and Enhancing Adaptive Capacities to Climate Change Jump to: navigation, search Name India-Vulnerability Assessment and Enhancing Adaptive Capacities...

  3. Bangladesh-Enhancing Capacity for Low Emission Development Strategies...

    Open Energy Info (EERE)

    Bangladesh-Enhancing Capacity for Low Emission Development Strategies (EC-LEDS) Jump to: navigation, search Name Bangladesh-Enhancing Capacity for Low Emission Development...

  4. South Africa-Developing Climate Policy Capacity within the South...

    Open Energy Info (EERE)

    South Africa-Developing Climate Policy Capacity within the South African Department of Environmental Affairs (DEA) (Redirected from GIZ-Developing Climate Policy Capacity within...

  5. Indonesia-ECN Capacity building for energy policy formulation...

    Open Energy Info (EERE)

    Indonesia-ECN Capacity building for energy policy formulation and implementation of sustainable energy projects Jump to: navigation, search Name CASINDO: Capacity development and...

  6. Wireless Battery Management System for Safe High-Capacity Energy...

    Office of Scientific and Technical Information (OSTI)

    Wireless Battery Management System for Safe High-Capacity Energy Storage Citation Details In-Document Search Title: Wireless Battery Management System for Safe High-Capacity Energy...

  7. HT Combinatorial Screening of Novel Materials for High Capacity...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    HT Combinatorial Screening of Novel Materials for High Capacity Hydrogen Storage HT Combinatorial Screening of Novel Materials for High Capacity Hydrogen Storage Presentation for...

  8. CLEAN-Capacity Building and Training for Low Emissions Development...

    Open Energy Info (EERE)

    (LEDS): Capacity Building and Training to explore activity design, lessons learned, future capacity building plans, major ongoing needs and opportunities for enhanced...

  9. Representation of Solar Capacity Value in the ReEDS Capacity Expansion Model

    SciTech Connect (OSTI)

    Sigrin, B.; Sullivan, P.; Ibanez, E.; Margolis, R.

    2014-03-01

    An important issue for electricity system operators is the estimation of renewables' capacity contributions to reliably meeting system demand, or their capacity value. While the capacity value of thermal generation can be estimated easily, assessment of wind and solar requires a more nuanced approach due to the resource variability. Reliability-based methods, particularly assessment of the Effective Load-Carrying Capacity, are considered to be the most robust and widely-accepted techniques for addressing this resource variability. This report compares estimates of solar PV capacity value by the Regional Energy Deployment System (ReEDS) capacity expansion model against two sources. The first comparison is against values published by utilities or other entities for known electrical systems at existing solar penetration levels. The second comparison is against a time-series ELCC simulation tool for high renewable penetration scenarios in the Western Interconnection. Results from the ReEDS model are found to compare well with both comparisons, despite being resolved at a super-hourly temporal resolution. Two results are relevant for other capacity-based models that use a super-hourly resolution to model solar capacity value. First, solar capacity value should not be parameterized as a static value, but must decay with increasing penetration. This is because -- for an afternoon-peaking system -- as solar penetration increases, the system's peak net load shifts to later in the day -- when solar output is lower. Second, long-term planning models should determine system adequacy requirements in each time period in order to approximate LOLP calculations. Within the ReEDS model we resolve these issues by using a capacity value estimate that varies by time-slice. Within each time period the net load and shadow price on ReEDS's planning reserve constraint signals the relative importance of additional firm capacity.

  10. Data summary report for M.W. Kellogg Z-sorb sorbent tests. CRADA 92-008 Final report

    SciTech Connect (OSTI)

    Everett, C.E.; Monaco, S.J.

    1994-05-01

    A series of tests were undertaken from August 6, 1992 through July 6, 1993 at METC`s High Pressure Bench-Scale Hot Gas Desulfurization Unit to support a Cooperative Research and Development Agreement (CRADA) between METC`s Sorbent Development Cluster and M.W. Kellogg. The M.W. Kellogg Company is currently developing a commercial offering of a hot gas clean-up system to be used in Integrated Gasification Combined Cycle (IGCC) systems. The intent of the CRADA agreement was to identify a suitable zinc-based desulfurization sorbent for the Sierra Pacific Power Company Clean Coal Technology Project, to identify optimum operating conditions for the sorbent, and to estimate potential sorbent loss per year. This report presents results pertaining to Phillips Petroleum`s Z-Sorb III sorbent.

  11. Declared Wolf Creek

    Office of Environmental Management (EM)

    15-Nov 22-Nov 29-Nov 6-Dec 13-Dec 20-Dec 27-Dec 115% Nameplate Declared Wolf Creek UNIT 1 (MW) 52 45 52 52 52 52 52 52 52 52 52 52 52 UNIT 2 (MW) 52 45 52 52 52 52 52 52 52 52...

  12. CSEM WP 124 Capacity Markets for Electricity

    E-Print Network [OSTI]

    California at Berkeley. University of

    CSEM WP 124 Capacity Markets for Electricity Anna Creti, LEEERNA, University of Toulouse for Electricity Anna Creti LEEERNA, University of Toulouse Natalia Fabra Universidad Carlos III de Madrid February 2004 Abstract The creation of electricity markets has raised the fundamental question as to whether

  13. STORAGE CAPACITY ALLOCATION ALGORITHMS FOR HIERARCHICAL

    E-Print Network [OSTI]

    Stavrakakis, Ioannis

    STORAGE CAPACITY ALLOCATION ALGORITHMS FOR HIERARCHICAL CONTENT DISTRIBUTION Nikolaos Laoutaris of Athens, 15784 Athens, Greece {laoutaris,vassilis,istavrak}@di.uoa.gr Abstract The addition of storage storage budget to the nodes of a hierarchical con- tent distribution system is formulated; optimal

  14. Fagatele Bay National Marine Sanctuary GIS Capacity

    E-Print Network [OSTI]

    Wright, Dawn Jeannine

    Fagatele Bay National Marine Sanctuary GIS Capacity Binder Index Background 2 Hardware, Software Report, configuration notes American Samoa Spatial Data Infrastructure Maps GIS Data CDs Operating System) #12;Compiled by Allison Graves, Nuna Technologies 2002. 2 Background A GIS presence was established

  15. FURTHER EXPERIMENTS IN FISHWAY CAPACITY, 1957

    E-Print Network [OSTI]

    in the fishway . Experiments in 1956 to measure the capacity of a pool-and-overf all- type fish- way were to accommodate the runs effec- tively. Appreciable savings in construction \\J Research financed by the U.S. Army of providing design criteria for more economical and more efficient fish-passage facili- ties at Corps projects

  16. Emergent Biosynthetic Capacity in Simple Microbial Communities

    E-Print Network [OSTI]

    Borenstein, Elhanan

    Emergent Biosynthetic Capacity in Simple Microbial Communities Hsuan-Chao Chiu1 , Roie Levy1 and dynamics of simple two-species microbial ecosystems. We specifically focus on detecting emergent a large collection of two-species communities on multiple media, we demonstrate that emergent biosynthetic

  17. tti.tamu.edu Increasing Capacity,

    E-Print Network [OSTI]

    Readers to Measure Wait Times at the U.S.-Mexico Border Computer Simulations Explore "What If" Disaster Wait Times at the U.S.-Mexico Border 8 Safety-Belt Use at All-Time High in Texas 10 Increasing Capacity. Today -- with the Internet cross-pollinating cultures between countries at the speed of light

  18. Optimal Prices for Finite Capacity Queueing Systems

    E-Print Network [OSTI]

    Ziya, Serhan

    Optimal Prices for Finite Capacity Queueing Systems Serhan Ziya Department of Statistics prove a lower bound on the optimal price for a fairly large class of blocking systems with general arrival and service processes, determine optimal price expressions for M/M/1/m and M/GI/s/s systems

  19. Electricity market module: Electricity capacity planning submodule

    SciTech Connect (OSTI)

    NONE

    1996-06-01

    The purpose of this report is to describe modifications to the Electricity Capacity Planning Submodule (ECP) for the Annual Energy Outlook 1996. It describes revisions to enhance the representation of planned maintenance, incorporate technological improvements in operating efficiencies, revise the algorithm for determining international firm power imports, and include risk premiums for new plant construction.

  20. Computing Wireless Capacity Magnus M. Halldorsson

    E-Print Network [OSTI]

    Halldórsson, Magnús M.

    Computing Wireless Capacity Magn´us M. Halld´orsson Roger Wattenhofer September 27, 2010 Abstract In this paper we address two common questions in wireless communication from an algorithmic perspective, assuming a geometric path loss model: First, how long does it take to satisfy an arbitrary set of wireless

  1. On Asymptotic Outage Capacity Distribution of Correlated MIMO Channels

    E-Print Network [OSTI]

    Loyka, Sergey

    On Asymptotic Outage Capacity Distribution of Correlated MIMO Channels Georgy Levin* and Sergey condition for the asymptotic normality of MIMO channel outage capacity is considered. Some physical aspects, asymptotic capacity, correlation. I. INTRODUCTION Outage capacity is one of the major characteristics

  2. Air Pollution Control Regulations: No. 46 and 47- CO2 Budget Trading Program and Allowance Distribution (Rhode Island)

    Broader source: Energy.gov [DOE]

    For the purposes of these regulations, CO2 budget units are defined as units that serve an electricity generator with nameplate capacity greater than or equal to 25 MWe. The regulations describe...

  3. Abatement of Air Pollution: Control of Carbon Dioxide Emissions/Carbon Dioxide Budget Trading Program (Connecticut)

    Broader source: Energy.gov [DOE]

    Any source that serves an electricity generator with a nameplate capacity equal to or greater than 25 MWe is considered a CO2 budget source for the purpose of these regulations. This section lists...

  4. Selling Random Energy

    E-Print Network [OSTI]

    Bitar, Eilyan Yamen

    2011-01-01

    nameplate capacity of the wind farms. Source: BPA, 2008 (b)market participation of wind farms: the success story of the0, W i ] produced at wind farm i is modeled as a scalar

  5. Real-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation

    E-Print Network [OSTI]

    Wierman, Adam

    , e.g., plug-in electric vehicles, dryers, air conditioners, etc. The penetration of deferrable loads has a root-mean- square error of around 18% of the nameplate capacity look- ing 24 hours ahead [16

  6. Changes in the Economic Value of Variable Generation at High Penetration Levels: A Pilot Case Study of California

    E-Print Network [OSTI]

    Mills, Andrew

    2013-01-01

    for parabolic trough solar power plants. Energy, 29(5-6):of concentrating solar power plants: A case study of thesolar field relative to the nameplate capacity of the solar plant power

  7. DWEA Webinar: IRS Guidance for Small Wind Turbines

    Broader source: Energy.gov [DOE]

    The U.S. Internal Revenue Service (IRS) has issued Notice 2015-4 providing new performance and quality standards of small wind turbines – defined as having a nameplate capacity of up to 100 kW – in...

  8. Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1,000 Megawatts (MW) of New Wind Power in Maine (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-10-01

    The U.S. Department of Energy?s Wind Powering America Program is committed to educating state-level policymakers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Maine. Although construction and operation of 1000 MW of wind power is a significant effort, six states have already reached the 1000-MW mark. We forecast the cumulative economic benefits from 1000 MW of development in Maine to be $1.3 billion, annual CO2 reductions are estimated at 2.8 million tons, and annual water savings are 1,387 million gallons.

  9. Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1,000 Megawatts (MW) of New Wind Power in North Carolina (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2009-03-01

    The U.S. Department of Energy?s Wind Powering America Program is committed to educating state-level policymakers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in North Carolina. Although construction and operation of 1000 MW of wind power is a significant effort, seven states have already reached the 1000-MW mark. We forecast the cumulative economic benefits from 1000 MW of development in North Carolina to be $1.1 billion, annual CO2 reductions are estimated at 2.9 million tons, and annual water savings are 1,558 million gallons.

  10. Dynamometer Testing of Samsung 2.5MW Drivetrain: Cooperative Research and Development Final Report, CRADA Number CRD-08-311

    SciTech Connect (OSTI)

    Wallen, R.

    2011-02-01

    SHI's prototype 2.5 MW wind turbine drivetrain was tested at the NWTC 2.5 MW dynamometer test facility over the course of 4 months between December 2009 and March 2010. This successful testing campaign allowed SHI to validate performance, safety, control tuning, and reliability in a controlled environment before moving to full-scale testing and subsequent introduction of a commercial product into the American market.

  11. Entanglement area law from specific heat capacity

    E-Print Network [OSTI]

    Fernando G. S. L. Brandao; Marcus Cramer

    2015-08-20

    We study the scaling of entanglement in low-energy states of quantum many-body models on lattices of arbitrary dimensions. We allow for unbounded Hamiltonians such that systems with bosonic degrees of freedom are included. We show that if at low enough temperatures the specific heat capacity of the model decays exponentially with inverse temperature, the entanglement in every low-energy state satisfies an area law (with a logarithmic correction). This behaviour of the heat capacity is typically observed in gapped systems. Assuming merely that the low-temperature specific heat decays polynomially with temperature, we find a subvolume scaling of entanglement. Our results give experimentally verifiable conditions for area laws, show that they are a generic property of low-energy states of matter, and, to the best of our knowledge, constitute the first proof of an area law for unbounded Hamiltonians beyond those that are integrable.

  12. Florida products pipeline set to double capacity

    SciTech Connect (OSTI)

    True, W.R.

    1995-11-13

    Directional drilling has begun this fall for a $68.5 million, approximately 110,000 b/d expansion of Central Florida Pipeline Co.`s refined products line from Tampa to Orlando. The drilling started in August and is scheduled to conclude this month, crossing under seven water bodies in Hillsborough, Polk, and Osceola counties. The current 6 and 10-in. system provides more than 90% of the petroleum products used in Central Florida, according to Central Florida Pipeline. Its additional capacity will meet the growing region`s demand for gasoline, diesel, and jet fuel. The new pipeline, along with the existing 10-in. system, will increase total annual capacity from 30 million bbl (82,192 b/d) to approximately 70 million bbl (191,781 b/d). The older 6-in. line will be shutdown when the new line is operating fully. The steps of pipeline installation are described.

  13. Planned Geothermal Capacity | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975) | OpenBethlehemPlainsboro Center,Planned Geothermal Capacity

  14. Evaluation of battery converters based on 4. 8-MW fuel cell demonstrator inverter. Final report. [Contains brief glossary

    SciTech Connect (OSTI)

    Not Available

    1980-10-01

    Electrical power conditioning is a critical element in the development of advanced electrochemical energy storage systems. This program evaluates the use of existing self-commutated converter technology (as developed by the Power Systems Division of United Technologies for the 4.8-MW Fuel Cell Demonstrator) with modification for use in battery energy storage systems. The program consists of three parts: evaluation of the cost and performance of a self-commutated converter modified to maintain production commonality between battery and fuel cell power conditioners, demonstration of the principal characteristics required for the battery application in MW-scale hardware, and investigation of the technical requirements of operation isolated from the utility system. A power-conditioning system consisting of a self-commutated converter augmented with a phase-controlled rectifier was selected and a preliminary design, prepared. A principal factor in this selection was production commonality with the fuel cell inverter system. Additional types of augmentation, and the use of a self-commutated converter system without augmentation, were also considered. A survey of advanced battery manufacturers was used to establish the dc interface characteristics. The principal characteristics of self-commutated converter operation required for battery application were demonstrated with the aid of an available 0.5-MW development system. A survey of five REA and municipal utilities and three A and E firms was conducted to determine technical requirements for operation in a mode isolated from the utility. Definitive requirements for this application were not established because of the limited scope of this study. 63 figures, 37 tables.

  15. RELAP5-3D Results for Phase I (Exercise 2) of the OECD/NEA MHTGR-350 MW Benchmark

    SciTech Connect (OSTI)

    Gerhard Strydom

    2012-06-01

    The coupling of the PHISICS code suite to the thermal hydraulics system code RELAP5-3D has recently been initiated at the Idaho National Laboratory (INL) to provide a fully coupled prismatic Very High Temperature Reactor (VHTR) system modeling capability as part of the NGNP methods development program. The PHISICS code consists of three modules: INSTANT (performing 3D nodal transport core calculations), MRTAU (depletion and decay heat generation) and a perturbation/mixer module. As part of the verification and validation activities, steady state results have been obtained for Exercise 2 of Phase I of the newly-defined OECD/NEA MHTGR-350 MW Benchmark. This exercise requires participants to calculate a steady-state solution for an End of Equilibrium Cycle 350 MW Modular High Temperature Reactor (MHTGR), using the provided geometry, material, and coolant bypass flow description. The paper provides an overview of the MHTGR Benchmark and presents typical steady state results (e.g. solid and gas temperatures, thermal conductivities) for Phase I Exercise 2. Preliminary results are also provided for the early test phase of Exercise 3 using a two-group cross-section library and the Relap5-3D model developed for Exercise 2.

  16. How Accurate are the Gaussian and Gamma Approximations to the Outage Capacity of MIMO Channels ?

    E-Print Network [OSTI]

    Øien, Geir E.

    How Accurate are the Gaussian and Gamma Approximations to the Outage Capacity of MIMO Channels MIMO capacity complementary cumulative distribution functions, or equivalently, the outage capacity distribution function (CDF) (also known as the outage capacity), or equivalently, the capacity complementary

  17. Modeling Capacity Reservation in High-Tech Manufacturing

    E-Print Network [OSTI]

    Wu, David

    by rapid innovation and volatile demands. Capacity reservation provides a risk sharing mechanism, manufacturers are confronted with capital intensive facilities and highly skilled labor, operating under long. Physical expansion of manufacturing capacity involves enormous risk. This involves building new facil

  18. Healthcare Facility Location and Capacity Configuration under Stochastic Demand 

    E-Print Network [OSTI]

    Han, Xue

    2014-12-18

    This dissertation addresses two topics. The first topic is strategic dynamic supply chain reconfiguration (DSCR) problem, in which the proposed capacity configuration network is employed in the second topic: healthcare facility location and capacity...

  19. Storage and capacity rights markets in the natural gas industry

    E-Print Network [OSTI]

    Paz-Galindo, Luis A.

    1999-01-01

    This dissertation presents a different approach at looking at market power in capacity rights markets that goes beyond the functional aspects of capacity rights markets as access to transportation services. In particular, ...

  20. Design and Evaluation of Novel High Capacity Cathode Materials...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    D.C. esp13thackeray.pdf More Documents & Publications Design and Evaluation of High Capacity Cathodes Design and Evaluation of Novel High Capacity Cathode Materials Design and...

  1. DECENTRALIZING SEMICONDUCTOR CAPACITY PLANNING VIA INTERNAL MARKET COORDINATION

    E-Print Network [OSTI]

    Wu, David

    and S. DAVID WU Manufacturing Logistics Institute, Department of Industrial and Manufacturing Systems semiconductor manufacturer: marketing managers reserve capacity from manufacturing based on product demands, while attempting to maximize profit; manufacturing managers allocate capacity to competing marketing

  2. Evaluation of capacity release transactions in the natural gas industry

    E-Print Network [OSTI]

    Lautzenhiser, Stephen

    1994-01-01

    The purpose of this thesis is to analyze capacity release transactions in the natural gas industry and to state some preliminary conclusions about how the capacity release market is functioning. Given FERC's attempt to ...

  3. National CHP Roadmap: Doubling Combined Heat and Power Capacity...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    CHP Roadmap: Doubling Combined Heat and Power Capacity in the United States by 2010, March 2001 National CHP Roadmap: Doubling Combined Heat and Power Capacity in the United States...

  4. Property:Cooling Capacity | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo, Maryland:NPIProtectio1975)EnergyFloorAreaOfficesCollaborators Jump to:Capacity Jump to:

  5. Africa - CCS capacity building | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LIST OFAMERICA'SHeavyAgencyTendoMassachusetts: EnergyRenewablesAfrica - CCS capacity

  6. U.S. Refinery Utilization and Capacity

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking With WIPP UPDATE: AprilCubicProduction Capacity ofCrudeStocks

  7. Managing High-Tech Capacity Expansion Via Reservation Contracts

    E-Print Network [OSTI]

    Wu, David

    1 Managing High-Tech Capacity Expansion Via Reservation Contracts Murat Erkoc S. David Wuñ, Bethlehem, PA 18015 merkoc@miami.edu david.wu@lehigh.eduñ We study capacity reservation contracts in high-tech lead time. We conclude the paper by summarizing insights useful for high-tech capacity management. 1

  8. On The Outage Capacity Distribution of Correlated Keyhole MIMO Channels

    E-Print Network [OSTI]

    Loyka, Sergey

    On The Outage Capacity Distribution of Correlated Keyhole MIMO Channels G. Levin and S. Loyka for the instantaneous SNR and outage capacity distributions of a spatially correlated keyhole MIMO channel are given diversity channel with a single Tx (Rx) and multiple Rx (Tx) antennas. The outage capacity at low outage

  9. Multi-Keyhole MIMO Channels: Asymptotic Analysis of Outage Capacity

    E-Print Network [OSTI]

    Loyka, Sergey

    Multi-Keyhole MIMO Channels: Asymptotic Analysis of Outage Capacity George Levin and Sergey Loyka single-keyhole channels. The outage capacity distribution of both full-rank and rank-deficient multi channel, outage capacity, correlation. I. INTRODUCTION Multiple-Input-Multiple-Output (MIMO) channels have

  10. Does Beamforming achieve Outage Capacity with Direction Feedback?

    E-Print Network [OSTI]

    Jafar, Syed A.

    Does Beamforming achieve Outage Capacity with Direction Feedback? Sudhir Srinivasa and Syed Ali: syed@ece.uci.edu, sudhirs@uci.edu Email: sriram@ece.utexas.edu Abstract We explore the outage capacity of outage capacity for a quantized channel direction feedback system. The technique is used to establish

  11. Transmission capacity of CDMA ad hoc networks Steven Weber

    E-Print Network [OSTI]

    de Veciana, Gustavo

    Transmission capacity of CDMA ad hoc networks Steven Weber Dept. of ECE Drexel University and tolerate co-located simultaneous transmissions. We develop analytic results on the transmission capacity of a CDMA ad hoc network. Transmission capacity is defined as the maximum permissible density

  12. Energy and Capacity Polar and essentially-polar sets

    E-Print Network [OSTI]

    Khoshnevisan, Davar

    Energy and Capacity Polar and essentially-polar sets Choose and fix a Borel set G R, and define #12;86 13. Energy and Capacity (Why?) In particular, set G := {} to see that a singleton := 0. Definition 2. (µ ) is called the mutual -energy between µ and , and Cap(G) the -capacity of G

  13. Energy-Efficient Capacity Optimization in Wireless Networks

    E-Print Network [OSTI]

    Wang, Yu

    Energy-Efficient Capacity Optimization in Wireless Networks Lu Liu, Xianghui Cao, Yu Cheng, Lili Du capacity in the most energy-efficient manner over a general large-scale wireless network, say, a multi for computing the resource allocation that leads to optimal network capacity with minimal energy consumption

  14. Online Multicasting for Network Capacity Maximization in Energy-Constrained

    E-Print Network [OSTI]

    Liang, Weifa

    Online Multicasting for Network Capacity Maximization in Energy-Constrained Ad Hoc Networks Weifa of network capacity, network lifetime, and transmission energy consumption for each multicast request, the network capacity is proportional to the network lifetime if the transmission energy consumption for each

  15. Capacity of a Gaussian MAC with Energy Harvesting Transmit Nodes

    E-Print Network [OSTI]

    Sharma, Vinod

    Capacity of a Gaussian MAC with Energy Harvesting Transmit Nodes R Rajesh CABS, DRDO Bangalore buffer to store the harvested energy. First, we find the capacity region of a GMAC powered by transmit. Keywords: Energy harvesting, Gaussian multiple access chan- nel, Finite Buffer, Shannon capacity. I

  16. Energy-Efficient Adaptive MIMO Systems Leveraging Dynamic Spare Capacity

    E-Print Network [OSTI]

    de Veciana, Gustavo

    Energy-Efficient Adaptive MIMO Systems Leveraging Dynamic Spare Capacity Hongseok Kim, Chan, energy conservation, spare capacity I. INTRODUCTION Wireless cellular systems such as WiMAX are evolving capacity, it is achieved in most cases at the expense of much higher energy consumption resulting

  17. Improved Capacity Bounds for the Binary Energy Harvesting Channel

    E-Print Network [OSTI]

    Yener, Aylin

    Improved Capacity Bounds for the Binary Energy Harvesting Channel Kaya Tutuncuoglu1 , Omur Ozel2 the encoder has unit energy storage capacity. We first show that an encoding scheme based on block indexing/channel use. The capacity of additive white Gaussian noise (AWGN) energy harvesting channel was studied in [2

  18. Asia/Pacific refineries spark growth in conversion capacity

    SciTech Connect (OSTI)

    Rhodes, A.K.

    1995-12-18

    Led by refiners in the Asia/Pacific region, worldwide capacity for conversion processes, such as fluid catalytic cracking, hydrocracking, and coking, increased at a faster pace this year than did crude oil distillation capacity. Crude capacity showed only a small gain of 0.4% to 74.5 million b/d according to the Journal`s most recent survey of refining capacity. This article summarizes data from the survey on the largest refiners, capacities, conversion processes, fuel processes, processing comparison, and refinery size.

  19. Design and development of a 6 MW peak, 24 kW average power S-band klystron

    SciTech Connect (OSTI)

    Joshi, L.M.; Meena, Rakesh; Nangru, Subhash; Kant, Deepender; Pal, Debashis; Lamba, O.S.; Jindal, Vishnu; Jangid, Sushil Kumar, E-mail: joslm@rediffmail.com [Central Electronics Engineering Research Institute, Council of Scientific and Industrial Research, Pilani (India); Chakravarthy, D.P.; Dixit, Kavita [Bhabha Atomic Research Centre, Mumbai (India)

    2011-07-01

    A 6 MW peak, 24 kW average power S-band Klystron is under development at CEERI, Pilani under an MoU between BARC and CEERI. The design of the klystron has been completed. The electron gun has been designed using TRAK and MAGIC codes. RF cavities have been designed using HFSS and CST Microwave Studio while the complete beam wave interaction simulation has been done using MAGIC code. The thermal design of collector and RF window has been done using ANSYS code. A Gun Collector Test Module (GCTM) was developed before making actual klystron to validate gun perveance and thermal design of collector. A high voltage solid state pulsed modulator has been installed for performance valuation of the tube. The paper will cover the design aspects of the tube and experimental test results of GCTM and klystron. (author)

  20. TECHNICAL EVALUATION OF TEMPORAL GROUNDWATER MONITORING VARIABILITY IN MW66 AND NEARBY WELLS, PADUCAH GASEOUS DIFFUSION PLANT

    SciTech Connect (OSTI)

    Looney, B.; Eddy-Dilek, C.

    2012-08-28

    Evaluation of disposal records, soil data, and spatial/temporal groundwater data from the Paducah Gaseous Diffusion Plant (PGDP) Solid Waste Management Unit (SWMU) 7 indicate that the peak contaminant concentrations measured in monitoring well (MW) 66 result from the influence of the regional PGDP NW Plume, and does not support the presence of significant vertical transport from local contaminant sources in SWMU 7. This updated evaluation supports the 2006 conceptualization which suggested the high and low concentrations in MW66 represent different flow conditions (i.e., local versus regional influences). Incorporation of the additional lines of evidence from data collected since 2006 provide the basis to link high contaminant concentrations in MW66 (peaks) to the regional 'Northwest Plume' and to the upgradient source, specifically, the C400 Building Area. The conceptual model was further refined to demonstrate that groundwater and the various contaminant plumes respond to complex site conditions in predictable ways. This type of conceptualization bounds the expected system behavior and supports development of environmental cleanup strategies, providing a basis to support decisions even if it is not feasible to completely characterize all of the 'complexities' present in the system. We recommend that the site carefully consider the potential impacts to groundwater and contaminant plume migration as they plan and implement onsite production operations, remediation efforts, and reconfiguration activities. For example, this conceptual model suggests that rerouting drainage water, constructing ponds or basin, reconfiguring cooling water systems, capping sites, decommissioning buildings, fixing (or not fixing) water leaks, and other similar actions will potentially have a 'direct' impact on the groundwater contaminant plumes. Our conclusion that the peak concentrations in MW66 are linked to the regional PGDP NW Plume does not imply that there TCE is not present in SWMU 7. The available soil and groundwater data indicate that the some of the waste disposed in this facility contacted and/or were contaminated by TCE. In our assessment, the relatively small amount of TCE associated with SWMU 7 is not contributing detectable TCE to the groundwater and does not represent a significant threat to the environment, particularly in an area where remediation and/or management of TCE in the NW plume will be required for an extended timeframe. If determined to be necessary by the PGDP team and regulators, additional TCE characterization or cleanup activities could be performed. Consistent with the limited quantity of TCE in SWMU 7, we identify a range of low cost approaches for such activities (e.g., soil gas surveys for characterization or SVE for remediation). We hope that this information is useful to the Paducah team and to their regulators and stakeholders to develop a robust environmental management path to address the groundwater and soil contamination associated with the burial ground areas.

  1. Rotational Augmentation on a 2.3 MW Rotor Blade with Thick Flatback Airfoil Cross-Sections: Preprint

    SciTech Connect (OSTI)

    Schreck, S.; Fingersh, L.; Siegel, K.; Singh, M.; Medina, P.

    2013-01-01

    Rotational augmentation was analyzed for a 2.3 MW wind turbine, which was equipped with thick flatback airfoils at inboard radial locations and extensively instrumented for acquisition of time varying surface pressures. Mean aerodynamic force and surface pressure data were extracted from an extensive field test database, subject to stringent criteria for wind inflow and turbine operating conditions. Analyses of these data showed pronounced amplification of aerodynamic forces and significant enhancements to surface pressures in response to rotational influences, relative to two-dimensional, stationary conditions. Rotational augmentation occurrence and intensity in the current effort was found to be consistent with that observed in previous research. Notably, elevated airfoil thickness and flatback design did not impede rotational augmentation.

  2. Information storage capacity of discrete spin systems

    E-Print Network [OSTI]

    Beni Yoshida

    2012-12-24

    Understanding the limits imposed on information storage capacity of physical systems is a problem of fundamental and practical importance which bridges physics and information science. There is a well-known upper bound on the amount of information that can be stored reliably in a given volume of discrete spin systems which are supported by gapped local Hamiltonians. However, all the previously known systems were far below this theoretical bound, and it remained open whether there exists a gapped spin system that saturates this bound. Here, we present a construction of spin systems which saturate this theoretical limit asymptotically by borrowing an idea from fractal properties arising in the Sierpinski triangle. Our construction provides not only the best classical error-correcting code which is physically realizable as the energy ground space of gapped frustration-free Hamiltonians, but also a new research avenue for correlated spin phases with fractal spin configurations.

  3. Improvement of load-following capacity based on the flame radiation intensity signal in a power plant

    SciTech Connect (OSTI)

    Fei Wang; Qunxing Huang; Dong Liu; Jianhua Yan; Kefa Cen [Zhejiang University, Hangzhou (China). State Key Laboratory of Clean Energy Utilization

    2008-05-15

    The capability to perform fast load changes has been an important issue due to the increasing commercialization of the power market. In the traditional boiler control system, the feedback signals come from the variations of the steam pressure and the steam flow, which leads to a large time delay. Therefore, a new method for the boiler control system based on radiation intensity for improving the load-following capacity of a coal-fired power plant has been developed in this paper. The system is implemented by adding the radiation intensity of the flame to the existing boiler control system as a complement. The radiation intensity obtained by the sensor can directly reflect the input heat in the boiler, with a faster response and higher sensitivity. Field tests on a 300 MW coal-fired power plant reveal that the improved boiler control system increases the load-following capacity. At the same time, the steam pressure variations are smaller as compared with those of the existing control system. 14 refs., 19 figs., 1 tab.

  4. Encouraging Combined Heat and Power in California Buildings

    E-Print Network [OSTI]

    Stadler, Michael

    2014-01-01

    PV capacities (GW) installed Solar Thermal capacities (MW) installed Solar Thermal capacities (GW) electricityGW) installed Solar Thermal capacities (MW) installed Solar

  5. Economic Benefits, Carbon Dioxide (CO2) Emissions Reduction, and Water Conservation Benefits from 1,000 Megawatts (MW) of New Wind Power in Georgia (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-06-01

    The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Georgia. We forecast the cumulative economic benefits from 1000 MW of development in Georgia to be $2.1 billion, annual CO2 reductions are estimated at 3.0 million tons, and annual water savings are 1,628 million gallons.

  6. Economic Benefits, Carbon Dioxide (CO2) Emissions reductions, and Water Conservation Benefits from 1,000 Megawatts (MW) of New Wind Power in New York (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-06-01

    The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in New York. We forecast the cumulative economic benefits from 1000 MW of development in New York to be $1.3 billion, annual CO2 reductions are estimated at 2.5 million tons, and annual water savings are 1,230 million gallons.

  7. Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1,000 Megawatts (MW) of New Wind Power in Virginia (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-06-01

    The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Virginia. We forecast the cumulative economic benefits from 1000 MW of development in Virginia to be $1.2 billion, annual CO2 reductions are estimated at 3.0 million tons, and annual water savings are 1,600 million gallons.

  8. Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1000 Megawatts (MW) of New Wind Power in Michigan

    SciTech Connect (OSTI)

    Not Available

    2008-06-01

    The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Michigan. We forecast the cumulative economic benefits from 1000 MW of development in Michigan to be $1.3 billion, annual CO2 reductions are estimated at 2.9 million tons, and annual water savings are 1,542 million gallons.

  9. Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1000 Megawatts (MW) of New Wind Power in Nebraska (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-06-01

    The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Nebraska. We forecast the cumulative economic benefits from 1000 MW of development in Nebraska to be $1.1 billion, annual CO2 reductions are estimated at 4.1 million tons, and annual water savings are 1,840 million gallons.

  10. Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1000 Megawatts (MW) of New Wind Power in Maryland (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-06-01

    The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Michigan. We forecast the cumulative economic benefits from 1000 MW of development in Maryland to be $1.2 billion, annual CO2 reductions are estimated at 3 million tons, and annual water savings are 1,581 million gallons.

  11. Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1,000 Megawatts (MW) of New Wind Power in Arkansas (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-06-01

    The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Arkansas. We forecast the cumulative economic benefits from 1000 MW of development in Arkansas to be $1.15 billion, annual CO2 reductions are estimated at 2.7 million tons, and annual water savings are 1,507 million gallons.

  12. Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1000 Megawatts (MW) of New Wind Power in Ohio (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-06-01

    The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Ohio. We forecast the cumulative economic benefits from 1000 MW of development in Ohio to be $1.3 billion, annual CO2 reductions are estimated at 2.5 million tons, and annual water savings are 1,343 million gallons.

  13. Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1,000 Megawatts (MW) of New Wind Power in Kansas (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-06-01

    The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Kansas. We forecast the cumulative economic benefits from 1000 MW of development in Kansas to be $1.08 billion, annual CO2 reductions are estimated at 3.2 million tons, and annual water savings are 1,816 million gallons.

  14. Modeling the Capacity and Emissions Impacts of Reduced Electricity Demand. Part 1. Methodology and Preliminary Results.

    E-Print Network [OSTI]

    Coughlin, Katie

    2013-01-01

    in emissions, primary energy, capacity and composition ofin primary energy use, emissions and capacity and the changei.e. energy, upper plots) and capacity variables. The plots

  15. Sixth Northwest Conservation and Electric Power Plan Chapter 12: Capacity and Flexibility Resources

    E-Print Network [OSTI]

    ..................................................................................................................................... 2 Power System Requirements: Capacity, Energy, and FlexibilitySixth Northwest Conservation and Electric Power Plan Chapter 12: Capacity and Flexibility Resources................................................... 2 Capacity: Meeting Peak Demand

  16. Building Capacity to Transform Zambia: What Motivates Government Officials to Learn Planning-related Skills?

    E-Print Network [OSTI]

    Kudo, Kana

    2015-01-01

    Department (2005). Capacity Building in Africa: An OEDModel): JICA Capacity Building Project for Implementation ofUnderstanding Capacity-Building Needs: Current Models for

  17. Surface and bulk modified high capacity layered oxide cathodes with low irreversible capacity loss

    DOE Patents [OSTI]

    Manthiram, Arumugam (Austin, TX); Wu, Yan (Austin, TX)

    2010-03-16

    The present invention includes compositions, surface and bulk modifications, and methods of making of (1-x)Li[Li.sub.1/3Mn.sub.2/3]O.sub.2.xLi[Mn.sub.0.5-yNi.sub.0.5-yCo.sub.2- y]O.sub.2 cathode materials having an O3 crystal structure with a x value between 0 and 1 and y value between 0 and 0.5, reducing the irreversible capacity loss in the first cycle by surface modification with oxides and bulk modification with cationic and anionic substitutions, and increasing the reversible capacity to close to the theoretical value of insertion/extraction of one lithium per transition metal ion (250-300 mAh/g).

  18. The NASA CSTI High Capacity Power Project

    SciTech Connect (OSTI)

    Winter, J.; Dudenhoefer, J.; Juhasz, A.; Schwarze, G.; Patterson, R.; Ferguson, D.; Titran, R.; Schmitz, P.; Vandersande, J.

    1994-09-01

    The SP-100 Space Nuclear Power Program was established in 1983 by DOD, DOE, and NASA as a joint program to develop technology for military and civil applications. Starting in 1986, NASA has funded a technology program to maintain the momentum of promising aerospace technology advancement started during Phase I of SP-100 and to strengthen, in key areas, the changes for successful development and growth capability of space nuclear reactor power systems for a wide range of future space applications. The elements of the CSTI High Capacity Power Project include Systems Analysis, Stirling Power Conversion, Thermoelectric Power Conversion, Thermal Management, Power Management, Systems Diagnostics, Environmental Interactions, and Material/Structural Development. Technology advancement in all elements is required to provide the growth capability, high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems. The overall project with develop and demonstrate the technology base required to provide a wide range of modular power systems compatible with the SP-100 reactor which facilitates operation during lunar and planetary day/night cycles as well as allowing spacecraft operation at any attitude or distance from the sun. Significant accomplishments in all of the project elements will be presented, along with revised goals and project timelines recently developed.

  19. Development of High-Capacity Cathode Materials with Integrated...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    & Publications Development of High-Capacity Cathode Materials with Integrated Structures Vehicle Technologies Office Merit Review 2015: Design and Evaluation of High...

  20. Initial Production Capacity Investments for Commercializing Pharmaceutical Products

    E-Print Network [OSTI]

    Yuen, Ming Kwan

    2012-01-01

    Hanan. 1982. Operations research and capacity expansionEngi- neering and Operations Research Department forstochastic demands. Operations Research 40 pp. S210–S216.

  1. Republic of Macedonia-Enhancing Capacity for Low Emission Development...

    Open Energy Info (EERE)

    Strategies (EC-LEDS) Jump to: navigation, search Name Republic of Macedonia-Enhancing Capacity for Low Emission Development Strategies (EC-LEDS) AgencyCompany Organization...

  2. Design and Evaluation of Novel High Capacity Cathode Materials...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    s049thackeray2012p.pdf More Documents & Publications Design and Evaluation of High Capacity Cathodes Vehicle Technologies Office Merit Review 2014: Design and Evaluation of High...

  3. Cambodia-Enhancing Capacity for Low Emission Development Strategies...

    Open Energy Info (EERE)

    Development Strategies (EC-LEDS) Jump to: navigation, search Name Cambodia-Enhancing Capacity for Low Emission Development Strategies (EC-LEDS) AgencyCompany Organization...

  4. Design and Evaluation of Novel High Capacity Cathode Materials...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    & Publications Lithium Source For High Performance Li-ion Cells Design and Evaluation of Novel High Capacity Cathode Materials Lithium Source For High Performance Li-ion Cells...

  5. Indonesia-Strengthening Planning Capacity for Low Carbon Growth...

    Open Energy Info (EERE)

    in Developing Asia Jump to: navigation, search Name Indonesia-Strengthening Planning Capacity for Low Carbon Growth in Developing Asia AgencyCompany Organization Asian...

  6. Enhancing Capacity for Low Emission Development Strategies (EC...

    Open Energy Info (EERE)

    Generation Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Enhancing Capacity for Low Emission Development Strategies (EC-LEDS): Distributed Generation Agency...

  7. Philippines-Strengthening Planning Capacity for Low Carbon Growth...

    Open Energy Info (EERE)

    in Developing Asia Jump to: navigation, search Name Philippines-Strengthening Planning Capacity for Low Carbon Growth in Developing Asia AgencyCompany Organization Asian...

  8. Design and Evaluation of Novel High Capacity Cathode Materials...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications Design and Evaluation of Novel High Capacity Cathode Materials Lithium Source For High Performance Li-ion Cells Lithium Source For...

  9. Design and Evaluation of Novel High Capacity Cathode Materials...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    49thackeray2011o.pdf More Documents & Publications Cathodes Design and Evaluation of Novel High Capacity Cathode Materials Layered Cathode Materials...

  10. Africa Adaptation Programme: Capacity Building Experiences-Improving...

    Open Energy Info (EERE)

    Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Africa Adaptation Programme: Capacity Building Experiences-Improving Access, Understanding and Application of Climate...

  11. Vietnam-Strengthening Planning Capacity for Low Carbon Growth...

    Open Energy Info (EERE)

    Growth in Developing Asia Jump to: navigation, search Name Vietnam-Strengthening Planning Capacity for Low Carbon Growth in Developing Asia AgencyCompany Organization Asian...

  12. Strengthening Planning Capacity for Low Carbon Growth in Developing...

    Open Energy Info (EERE)

    Asia - Thailand Jump to: navigation, search Name Thailand-Strengthening Planning Capacity for Low Carbon Growth in Developing Asia AgencyCompany Organization Asian...

  13. Mesoporous Manganese Oxide Nanowires for High-Capacity, High...

    Office of Scientific and Technical Information (OSTI)

    Mesoporous Manganese Oxide Nanowires for High-Capacity, High-Rate, Hybrid Electrical Energy Storage Citation Details In-Document Search Title: Mesoporous Manganese Oxide Nanowires...

  14. ,"New Mexico Natural Gas Underground Storage Capacity (MMcf)...

    U.S. Energy Information Administration (EIA) Indexed Site

    Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","New Mexico Natural Gas Underground Storage Capacity (MMcf)",1,"Annual",2014 ,"Release Date:","9...

  15. Prices, capacities and service quality in a congestible Bertrand duopoly

    E-Print Network [OSTI]

    De Borger, Bruno; Van Dender, Kurt

    2005-01-01

    Dender, Kurt. 2004. “Duopoly prices under congested access,”of demand on capacities and prices, see (3), has been madefacilities, even when price discrimination is allowed. r dq

  16. Renewable Motor Fuel Production Capacity Under H.R.4

    Reports and Publications (EIA)

    2002-01-01

    This paper analyzes renewable motor fuel production capacity with the assumption that ethanol will be used to meet the renewable fuels standard.

  17. Is there life in other markets? BPA explores preschedule capacity

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    new process this spring to acquire preschedule (day-ahead) capacity from third-party suppliers. The goal was to prevent occasional balancing reserve reductions caused by...

  18. JOURNAL OF GEOPHYSICAL RESEARCH, VOL. ???, XXXX, DOI:10.1029/, The 2011 Mw 7.1 Van (Eastern Turkey) Earthquake -1

    E-Print Network [OSTI]

    Cambridge, University of

    JOURNAL OF GEOPHYSICAL RESEARCH, VOL. ???, XXXX, DOI:10.1029/, The 2011 Mw 7.1 Van (Eastern Turkey, 2012, 5:45pm D R A F T #12;X - 2 ELLIOTT ET AL.: 2011 VAN EARTHQUAKE, EASTERN TURKEY moment and source.: 2011 VAN EARTHQUAKE, EASTERN TURKEY X - 3 Interferograms from the ENVISAT satellite were derived from

  19. CRN Title Units Instructor Days/Time 73865 EEC 289L Molecular Electronics 4 Josh Hihath MW 2:10 4:00pm

    E-Print Network [OSTI]

    Yoo, S. J. Ben

    CRN Title Units Instructor Days/Time 73865 EEC 289L Molecular Electronics 4 Josh Hihath MW 2:10 4L (EEC241) Molecular Electronics Instructor: Dr. Josh Hihath Email: jhihath@ucdavis.edu Course Description: EEC289L (EEC241) ­ Molecular Electronics: (4 units) Lecture/Discussion-4 hours. This course

  20. Rupture process of the 2014 Cephalonia, Greece, earthquake doublet1 (Mw6) as inferred from regional and local seismic data2

    E-Print Network [OSTI]

    Cerveny, Vlastislav

    1 Rupture process of the 2014 Cephalonia, Greece, earthquake doublet1 (Mw6) as inferred from- Seismological Laboratory, Greece.5 2 Aristotle University of Thessaloniki, Department of Geophysics, Greece.6 3 author: Efthimios Sokos, University of Patras, Department of Geology- Seismological10 Laboratory, Greece

  1. Baseline System Costs for 50.0 MW Enhanced Geothermal System--A Function of: Working Fluid, Technology, and Location, Location, Location

    Office of Energy Efficiency and Renewable Energy (EERE)

    Project objectives: Develop a baseline cost model of a 50.0 MW Enhanced Geothermal System, including all aspects of the project, from finding the resource through to operation, for a particularly challenging scenario: the deep, radioactively decaying granitic rock of the Pioneer Valley in Western Massachusetts.

  2. A 1V, 1mW, 4GHz Injection-Locked Oscillator for High-Performance Lin Zhang, Berkehan Ciftcioglu, and Hui Wu

    E-Print Network [OSTI]

    Wu, Hui

    to generate differential signals and then directly inject them into the ILO core. It also incorporates topology with direct transformer injection and switched capacitor array. which cancels some of the powerA 1V, 1mW, 4GHz Injection-Locked Oscillator for High-Performance Clocking Lin Zhang, Berkehan

  3. A Test of a Strong Ground Motion Prediction Methodology for the 7 September 1999, Mw=6.0 Athens Earthquake

    SciTech Connect (OSTI)

    Hutchings, L; Ioannidou, E; Voulgaris, N; Kalogeras, I; Savy, J; Foxall, W; Stavrakakis, G

    2004-08-06

    We test a methodology to predict the range of ground-motion hazard for a fixed magnitude earthquake along a specific fault or within a specific source volume, and we demonstrate how to incorporate this into probabilistic seismic hazard analyses (PSHA). We modeled ground motion with empirical Green's functions. We tested our methodology with the 7 September 1999, Mw=6.0 Athens earthquake, we: (1) developed constraints on rupture parameters based on prior knowledge of earthquake rupture processes and sources in the region; (2) generated impulsive point shear source empirical Green's functions by deconvolving out the source contribution of M < 4.0 aftershocks; (3) used aftershocks that occurred throughout the area and not necessarily along the fault to be modeled; (4) ran a sufficient number of scenario earthquakes to span the full variability of ground motion possible; (5) found that our distribution of synthesized ground motions span what actually occurred and their distribution is realistically narrow; (6) determined that one of our source models generates records that match observed time histories well; (7) found that certain combinations of rupture parameters produced ''extreme'' ground motions at some stations; (8) identified that the ''best fitting'' rupture models occurred in the vicinity of 38.05{sup o} N 23.60{sup o} W with center of rupture near 12 km, and near unilateral rupture towards the areas of high damage, and this is consistent with independent investigations; and (9) synthesized strong motion records in high damage areas for which records from the earthquake were not recorded. We then developed a demonstration PSHA for a source region near Athens utilizing synthesized ground motion rather that traditional attenuation. We synthesized 500 earthquakes distributed throughout the source zone likely to have Mw=6.0 earthquakes near Athens. We assumed an average return period of 1000 years for this magnitude earthquake in the particular source zone, thereby having simulated a catalog of ground motion for a period of 500,000 years. The distribution of traditional ground motion parameters of peak acceleration or spectral ordinates then becomes the synthesized record from which we develop hazard curves in the form of the annual probability of exceedance. This approach replaces the aleatory uncertainty that current PSHA studies estimate by regression of empirical parameters from the worldwide database with epistemic uncertainty on what specific sources actually do at specific sites. This is a fundamental change for PSHA and eliminates the need to extrapolate current empirical data that was gathered over about 50 years to represent values for 10{sup -3} annual probability of exceedance or less. This difference becomes especially significant for very sensitive structures that require estimates for 10{sup -5} or less exceedance.

  4. Incorporating Demand Resources into ISO New England’s Forward Capacity Market 

    E-Print Network [OSTI]

    Winkler, E.

    2008-01-01

    of 2007 that defined 6,102 megawatts (MW) of new demand- and supply-side resources now eligible to compete in the market. Approximately 40 percent—or 2,483 MW—of the new, qualified projects are demand-side resources such as demand response, energy...

  5. Multi-MW 22.8 GHz Harmonic Multiplier - RF Power Source for High-Gradient Accelerator R&D

    SciTech Connect (OSTI)

    Jay L. Hirshfield

    2012-07-26

    Electrodynamic and particle simulation studies have been carried out to optimize design of a two-cavity harmonic frequency multiplier, in which a linear electron beam is energized by rotating fields near cyclotron resonance in a TE111 cavity in a uniform magnetic field, and in which the beam then radiates coherently at the nth harmonic into a TEn11 output cavity. Examples are worked out in detail for 7th and 2nd harmonic converters, showing RF-to-RF conversion efficiencies of 45% and 88%, respectively at 19.992 GHz (K-band) and 5.712 GHz (C-band), for a drive frequency of 2.856 GHz. Details are shown of RF infrastructure (S-band klystron, modulator) and harmonic converter components (drive cavity, output cavities, electron beam source and modulator, beam collector) for the two harmonic converters to be tested. Details are also given for the two-frequency (S- and C-band) coherent multi-MW test stand for RF breakdown and RF gun studies.

  6. Klystron Linearizer for Use with 1.2 MW 476 MHz Klystrons in PEP-II RF Systems

    SciTech Connect (OSTI)

    Fox, J.; Mastorides, T.; Teytelman, D.; Van Winkle, D.; Zhou, Y.; /SLAC; Gallo, A.; /Frascati

    2005-06-15

    The direct and comb loop feedback around the RF cavities in PEP-II is critical in reducing longitudinal instabilities driven by the cavity impedance. The non-linear 1.2 MW klystron is in the signal path for these feedback loops. As a result, the effective small-signal gain of the klystron at 85% saturation reduces the impedance control by factors of 5 to 20 as compared to a linear power amplifier. A klystron linearizer circuit has been developed which operates in series with the power amplifier and acts to equalize the small and large signal gains through the combination. The technique must implement a 1 MHz linear control bandwidth over roughly 15 dB of RF signal level variation. The dynamics of this system is operating point dependent, and the channel must have dynamic gain compensation to keep the linearity compensation loop stable over changes in operating point. The design of this non-linear signal processing channel (incorporating RF and DSP techniques) and measured results from full-power klystron testing are presented.

  7. Test and Development of a 10 MW 1.3 GHz Sheet Beam Klystron for the ILC

    SciTech Connect (OSTI)

    Sprehn, Daryl; /SLAC; Haase, Andrew; /SLAC; Jensen, Aaron; /SLAC; Jongewaard, Erik; /SLAC; Martin, David; /SLAC

    2012-07-03

    The SLAC National Accelerator Laboratory Klystron Department is developing a 10 MW, 5 Hz, 1.6 ms, 1.3 GHz plug-compatible Sheet-Beam Klystron as a less expensive and more compact alternative to the ILC baseline Multiple-Beam Klystron. Earlier this year a beam tester was constructed and began test. Device fabrication issues have complicated the analysis of the data collected from an intercepting cup for making beam quality measurements of the 130 A, 40-to-1 aspect ratio beam. Since the goal of the beam tester is to confirm 3d beam simulations it was necessary to rebuild the device in order to mitigate unwanted effects due to imperfect focusing construction. Measurements are underway to verify the results of this latest incarnation. Measurement will then be made of the beam after transporting through a drift tube and magnetic focusing system. In the klystron design, a TE oscillation was discovered during long simulation runs of the entire device which has since prompted two design changes to eliminate the beam disruption. The general theory of operation, the design choices made, and results of testing of these various devices will be discussed.

  8. Wake Turbulence of Two NREL 5-MW Wind Turbines Immersed in a Neutral Atmospheric Boundary-Layer Flow

    E-Print Network [OSTI]

    Bashioum, Jessica L; Schmitz, Sven; Duque, Earl P N

    2013-01-01

    The fluid dynamics video considers an array of two NREL 5-MW turbines separated by seven rotor diameters in a neutral atmospheric boundary layer (ABL). The neutral atmospheric boundary-layer flow data were obtained from a precursor ABL simulation using a Large-Eddy Simulation (LES) framework within OpenFOAM. The mean wind speed at hub height is 8m/s, and the surface roughness is 0.2m. The actuator line method (ALM) is used to model the wind turbine blades by means of body forces added to the momentum equation. The fluid dynamics video shows the root and tip vortices emanating from the blades from various viewpoints. The vortices become unstable and break down into large-scale turbulent structures. As the wakes of the wind turbines advect further downstream, smaller-scale turbulence is generated. It is apparent that vortices generated by the blades of the downstream wind turbine break down faster due to increased turbulence levels generated by the wake of the upstream wind turbine.

  9. Kauai Island Utility Co-op (KIUC) PV integration study.

    SciTech Connect (OSTI)

    Ellis, Abraham; Mousseau, Tom

    2011-08-01

    This report investigates the effects that increased distributed photovoltaic (PV) generation would have on the Kauai Island Utility Co-op (KIUC) system operating requirements. The study focused on determining reserve requirements needed to mitigate the impact of PV variability on system frequency, and the impact on operating costs. Scenarios of 5-MW, 10-MW, and 15-MW nameplate capacity of PV generation plants distributed across the Kauai Island were considered in this study. The analysis required synthesis of the PV solar resource data and modeling of the KIUC system inertia. Based on the results, some findings and conclusions could be drawn, including that the selection of units identified as marginal resources that are used for load following will change; PV penetration will displace energy generated by existing conventional units, thus reducing overall fuel consumption; PV penetration at any deployment level is not likely to reduce system peak load; and increasing PV penetration has little effect on load-following reserves. The study was performed by EnerNex under contract from Sandia National Laboratories with cooperation from KIUC.

  10. On the Capacity of Hybrid Wireless Networks Benyuan Liu

    E-Print Network [OSTI]

    Massachusetts at Amherst, University of

    On the Capacity of Hybrid Wireless Networks Benyuan Liu , Zhen Liu + , Don Towsley Department 704 Yorktown Heights, NY 10598 Abstract-- We study the throughput capacity of hybrid wireless networks stations are assumed to be connected by a high-bandwidth wired network and act as relays for wireless nodes

  11. A Framework for the Capacity Evaluation of Multihop Wireless Networks

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    A Framework for the Capacity Evaluation of Multihop Wireless Networks Herv´e Rivano CNRS - INRIA and localized CDS. Index Terms--network capacity, multihop wireless networks, upper and lower bounds, linear programing I. INTRODUCTION Ad hoc networks are spontaneous multihop topologies of wireless nodes

  12. Storage Capacity of the Exponential Correlation Associative Memory

    E-Print Network [OSTI]

    Hancock, Edwin

    In this paper we analyze the pattern storage capacity of the exponential correlation asso- ciative memory(ECAM of the ECAM when presented with corrupted input patterns. Our model leads to an expression for the storage capacity of the ECAM both in terms of the length of the bit-patterns and the probabil- ity of bit

  13. Outage and Capacity Analysis of Cellular CDMA With Admission Control

    E-Print Network [OSTI]

    Chockalingam, A.

    Outage and Capacity Analysis of Cellular CDMA With Admission Control S. AnandÝ , A. Chockalingam. Ltd., Bangalore, INDIA Abstract-- We analyze the outage and capacity performance of an interference based admission control strategy in cellular CDMA systems. Most approaches to estimate the outage

  14. IEED Tribal Energy Development to Build Tribal Energy Development Capacity

    Broader source: Energy.gov [DOE]

    The Assistant Secretary - Indian Affairs for the U.S. Department of the Interior, through the Office of Indian Energy and Economic Development, is soliciting grant proposals from Indian tribes to build tribal capacity for energy resource development or management under the Department of the Interior's (DOl's) Tribal Energy Development Capacity (TEDC) grant program.

  15. Shannon Capacity and Ramsey Numbers from Product of Graphs

    E-Print Network [OSTI]

    Radziszowski, Stanislaw P.

    Bounds on Shannon Capacity and Ramsey Numbers from Product of Graphs Xiaodong Xu Guangxi Academy Abstract In this paper we study Shannon capacity of channels in the context of classical Ramsey numbers. We by Abbott and Song and thus establish new lower bounds for a special type of multicolor Ramsey numbers. We

  16. Optimal Demand Response Capacity of Automatic Lighting Control

    E-Print Network [OSTI]

    Mohsenian-Rad, Hamed

    1 Optimal Demand Response Capacity of Automatic Lighting Control Seyed Ataollah Raziei and Hamed-mails: razieis1@udayton.edu and hamed@ee.ucr.edu Abstract--Demand response programs seek to ad- just the normal prior studies have extensively studied the capacity of offering demand response in buildings

  17. UMTS Capacity and Throughput Maximization for Different Spreading Factors

    E-Print Network [OSTI]

    Akl, Robert

    for signal-to-interference threshold from 5 dB to 10 dB and spreading factor values of 256, 64, 16, and 4 Erlang capacity based on the Lost Call Held (LCH) model as described in [4]. This algorithm calculates expression of Erlang capacity for a single type of traffic loading and compare analytical results

  18. ORIGINAL ARTICLE Effect of Different Sitting Postures on Lung Capacity,

    E-Print Network [OSTI]

    Makhsous, Mohsen

    ORIGINAL ARTICLE Effect of Different Sitting Postures on Lung Capacity, Expiratory Flow, and Lumbar, Makhsous M. Effect of different sitting postures on lung capacity, expiratory flow, and lumbar lordosis. Arch Phys Med Rehabil 2006;87:504-9. Objective: To investigate the effect of sitting posture on lung

  19. GROUNDWATER NITRATE REMOVAL CAPACITY OF RIPARIAN ZONES IN

    E-Print Network [OSTI]

    Gold, Art

    GROUNDWATER NITRATE REMOVAL CAPACITY OF RIPARIAN ZONES IN URBANIZING WATERSHEDS BY TARA KIMBERLY the watershed, however, is not well understood. Nitrate in groundwater moving through the "biologically active and geomorphology of riparian zones, potentially changing riparian groundwater denitrification capacity. Little work

  20. Maximum oxidative phosphorylation capacity of the mammalian heart

    E-Print Network [OSTI]

    Mootha, Vamsi K.

    Maximum oxidative phosphorylation capacity of the mammalian heart VAMSI K. MOOTHA, ANDREW E. ARAI, AND ROBERT S. BALABAN Laboratory of Cardiac Energetics, National Heart, Lung, and Blood Institute, National. Maximum oxidative phosphorylation capacity of the mammalian heart. Am. J. Physiol. 272 (Heart Circ

  1. Towards Optimal Capacity Segmentation with Hybrid Cloud Pricing

    E-Print Network [OSTI]

    Li, Baochun

    between periodic auctions and EC2 spot market. Furthermore, we formulate the optimal capacity segmentationTowards Optimal Capacity Segmentation with Hybrid Cloud Pricing Wei Wang, Baochun Li, and Ben Liang Department of Electrical and Computer Engineering University of Toronto Abstract--Cloud resources are usually

  2. Competitive Acquisition of Prioritizable Capacity-Based Ancillary Services

    E-Print Network [OSTI]

    the competitive procurement of capacity-based ancillary services (AS) in unbundled markets by the Independent Grid integrate the markets for ancillary services into the wholesale electricity market through the formulation1 Competitive Acquisition of Prioritizable Capacity-Based Ancillary Services Gianfranco Chicco

  3. Towards Optimal Capacity Segmentation with Hybrid Cloud Pricing

    E-Print Network [OSTI]

    Liang, Ben

    and EC2 spot market. Furthermore, we formulate the optimal capacity segmentation strategy as a MarkovTowards Optimal Capacity Segmentation with Hybrid Cloud Pricing Wei Wang, Baochun Li, and Ben Liang Department of Electrical and Computer Engineering University of Toronto Toronto, ON M5S 3G4, Canada weiwang

  4. PRODUCTION START-UP OF 2 MW a-Si PV MANUFACTURING LINE AT SOVLUX M. Im, X. Den& II. C. Ovshinsky,R. Crucetand S.R Ovshimky

    E-Print Network [OSTI]

    Deng, Xunming

    start-up efforts at the 2MW Sovlux photovoltaic production line. Triple-junction solar cells with higher Figure 1Device structureof triple-junction solar cells produced in Sovlux 2 Mw continwxls roll,ts> Figure 2 I-V curve of a triple-junction solar cell produced during the stat-up optimization. t53aina

  5. Lanai high-density irradiance sensor network for characterizing solar resource variability of MW-scale PV system.

    SciTech Connect (OSTI)

    Stein, Joshua S.; Johnson, Lars; Ellis, Abraham; Kuszmaul, Scott S.

    2012-01-01

    Sandia National Laboratories (Sandia) and SunPower Corporation (SunPower) have completed design and deployment of an autonomous irradiance monitoring system based on wireless mesh communications and a battery operated data acquisition system. The Lanai High-Density Irradiance Sensor Network is comprised of 24 LI-COR{reg_sign} irradiance sensors (silicon pyranometers) polled by 19 RF Radios. The system was implemented with commercially available hardware and custom developed LabVIEW applications. The network of solar irradiance sensors was installed in January 2010 around the periphery and within the 1.2 MW ac La Ola PV plant on the island of Lanai, Hawaii. Data acquired at 1 second intervals is transmitted over wireless links to be time-stamped and recorded on SunPower data servers at the site for later analysis. The intent is to study power and solar resource data sets to correlate the movement of cloud shadows across the PV array and its effect on power output of the PV plant. The irradiance data sets recorded will be used to study the shape, size and velocity of cloud shadows. This data, along with time-correlated PV array output data, will support the development and validation of a PV performance model that can predict the short-term output characteristics (ramp rates) of PV systems of different sizes and designs. This analysis could also be used by the La Ola system operator to predict power ramp events and support the function of the future battery system. This experience could be used to validate short-term output forecasting methodologies.

  6. A 12-MW-scale pilot study of in-duct scrubbing (IDS) using a rotary atomizer

    SciTech Connect (OSTI)

    Samuel, E.A.; Murphy, K.R.; Demian, A.

    1989-11-01

    A low-cost, moderate-removal efficiency, flue gas desulfurization (FGD) technology was selected by the US Department of Energy for pilot demonstration in its Acid Rain Precursor Control Technology Initiative. The process, identified as In-Duct Scrubbing (IDS), applies rotary atomizer techniques developed for lime-based spray dryer FGD while utilizing existing flue gas ductwork and particulate collectors. IDS technology is anticipated to result in a dry desulfurization process with a moderate removal efficiency (50% or greater) for high-sulfur coal-fired boilers. The critical elements for successful application are: (1) adequate mixing of sorbent droplets with flue gas for efficient reaction contact, (2) sufficient residence time to produce a non-wetting product, and (3) appropriate ductwork cross-sectional area to prevent deposition of wet reaction products before particle drying is comple. The ductwork in many older plants, previously modified to meet 1970 Clean Air Act requirements for particulate control, usually meet these criteria. A 12 MW-scale IDS pilot plant was constructed at the Muskingum River Plant of the American Electric Power System. The pilot plant, which operates from a slipstrem attached to the air-preheater outlet duct from the Unit 5 boiler at the Muskingum River Plant (which burns about 4% sulfur coal), is equipped with three atomizer stations to test the IDS concept in vertical and horizontal configurations. In addition, the pilot plant is equipped to test the effect of injecting IDS off- product upstream of the atomizer, on SO{sub 2}and NO{sub x} removals.

  7. Collection and conversion of silicon furnace waste gas into higher value products: Phase 3, 6 MW pilot plant dc closed furnace technology. Final report

    SciTech Connect (OSTI)

    Dosaj, V.D.

    1995-01-01

    The construction and operation of a 6 MW, closed dc furnace for smelting silicon was the primary focus of Phase 3. A 6 MW, dc closed furnace pilot plant was built in East Selkirk, Manitoba, Canada. The furnace is equipped with world`s most modern automatic control system used to control and monitor the process variables and operational data. This control system is suitable for commercial applications and could be used with either closed or open dc furnaces for smelting silicon or ferrosilicon. The construction was started in September 1990, and the facility was operational within 18 months. Following successful commissioning of the pilot plant in June 1992, twelve smelting test campaigns were conducted through November 1994.

  8. Design & development fo a 20-MW flywheel-based frequency regulation power plant : a study for the DOE Energy Storage Systems program.

    SciTech Connect (OSTI)

    Rounds, Robert (Beacon Power, Tyngsboro, MA); Peek, Georgianne Huff

    2009-01-01

    This report describes the successful efforts of Beacon Power to design and develop a 20-MW frequency regulation power plant based solely on flywheels. Beacon's Smart Matrix (Flywheel) Systems regulation power plant, unlike coal or natural gas generators, will not burn fossil fuel or directly produce particulates or other air emissions and will have the ability to ramp up or down in a matter of seconds. The report describes how data from the scaled Beacon system, deployed in California and New York, proved that the flywheel-based systems provided faster responding regulation services in terms of cost-performance and environmental impact. Included in the report is a description of Beacon's design package for a generic, multi-MW flywheel-based regulation power plant that allows accurate bids from a design/build contractor and Beacon's recommendations for site requirements that would ensure the fastest possible construction. The paper concludes with a statement about Beacon's plans for a lower cost, modular-style substation based on the 20-MW design.

  9. 500 MW X-Band RF System of a 0.25 GeV Electron LINAC for Advanced Compton Scattering Source Application

    SciTech Connect (OSTI)

    Chu, Tak Sum; /LLNL, Livermore; Anderson, Scott; /LLNL, Livermore; Barty, Christopher; /LLNL, Livermore; Gibson, David; /LLNL, Livermore; Hartemann, Fred; /LLNL, Livermore; Marsh, Roark; /LLNL, Livermore; Siders, Craig; /LLNL, Livermore; Adolphsen, Chris; /SLAC; Jongewaard, Erik; /SLAC; Raubenheimer, Tor; /SLAC; Tantawi, Sami; /SLAC; Vlieks, Arnold; /SLAC; Wang, Juwen; /SLAC

    2012-07-03

    A Mono-Energetic Gamma-Ray (MEGa-Ray) Compton scattering light source is being developed at LLNL in collaboration with the SLAC National Accelerator Laboratory. The electron beam for the Compton scattering interaction will be generated by a X-band RF gun and a X-band LINAC at the frequency of 11.424 GHz. High power RF in excess of 500 MW is needed to accelerate the electrons to energy of 250 MeV or greater for the interaction. Two high power klystron amplifiers, each capable of generating 50 MW, 1.5 msec pulses, will be the main high power RF sources for the system. These klystrons will be powered by state of the art solid-state high voltage modulators. A RF pulse compressor, similar to the SLED II pulse compressor, will compress the klystron output pulse with a power gain factor of five. For compactness consideration, we are looking at a folded waveguide setup. This will give us 500 MW at output of the compressor. The compressed pulse will then be distributed to the RF gun and to six traveling wave accelerator sections. Phase and amplitude control are located at the RF gun input and additional control points along the LINAC to allow for parameter control during operation. This high power RF system is being designed and constructed. In this paper, we will present the design, layout, and status of this RF system.

  10. 500 MW X-BAND RF SYSTEM OF A 0.25 GEV ELECTRON LINAC FOR ADVANCED COMPTON SCATTERING SOURCE APPLICATION

    SciTech Connect (OSTI)

    Chu, T S; Anderson, S G; Gibson, D J; Hartemann, F V; Marsh, R A; Siders, C; Barty, C P; Adolphsen, C; Jongewaard, E; Tantawi, S; Vlieks, A; Wang, J W; Raubenheimer, T

    2010-05-12

    A Mono-Energetic Gamma-Ray (MEGa-Ray) Compton scattering light source is being developed at LLNL in collaboration with SLAC National Accelerator Laboratory. The electron beam for the Compton scattering interaction will be generated by a X-band RF gun and a X-band LINAC at the frequency of 11.424 GHz. High power RF in excess of 500 MW is needed to accelerate the electrons to energy of 250 MeV or greater for the interaction. Two high power klystron amplifiers, each capable of generating 50 MW, 1.5 msec pulses, will be the main high power RF sources for the system. These klystrons will be powered by state of the art solid-state high voltage modulators. A RF pulse compressor, similar to the SLED II pulse compressor, will compress the klystron output pulse with a power gain factor of five. For compactness consideration, we are looking at a folded waveguide setup. This will give us 500 MW at output of the compressor. The compressed pulse will then be distributed to the RF gun and to six traveling wave accelerator sections. Phase and amplitude control are located at the RF gun input and additional control points along the LINAC to allow for parameter control during operation. This high power RF system is being designed and constructed. In this paper, we will present the design, layout, and status of this RF system.

  11. The multicast capacity region of large wireless networks

    E-Print Network [OSTI]

    Shah, Devavrat

    We study the problem of determining the multicast capacity region of a wireless network of n nodes randomly located in an extended area and communicating with each other over Gaussian fading channels. We obtain an explicit ...

  12. Creative agencies : a model for building community capacity

    E-Print Network [OSTI]

    Ramaccia, Elizabeth M. (Elizabeth Marie)

    2011-01-01

    This research investigates how existing initiatives based in artistic and non-artistic disciplines build indigenous capacity for leadership in disenfranchised communities through the application of the creative process. ...

  13. Predictive capacity planning modeling with tactical and strategic applications

    E-Print Network [OSTI]

    Zeppieri, Michael A. (Michael Anthony), 1975-

    2004-01-01

    The focus of my internship was the development of a predictive capacity planning model to characterize the storage requirements and space utilization for Amazon's Campbellsville (SDF) Fulfillment Center (FC). Amazon currently ...

  14. Strategies for Sharing Bottleneck Capacity among Buses and Cars

    E-Print Network [OSTI]

    Guler, Sukran Ilgin

    2012-01-01

    enable buses to bypass the car queues that still form atcrease a bottleneck’s car-carrying capacity, in comparisonthat significant reductions in car delays can result while

  15. Fail Safe Design for Large Capacity Lithium-ion Batteries

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Fail Safe Design for Large Capacity Lithium-ion Batteries NREL Commercialization & Tech Transfer Webinar March 27, 2011 Gi-Heon Kim gi-heon.kim@nrel.gov John Ireland, Kyu-Jin Lee,...

  16. ,"U.S. Underground Natural Gas Storage Capacity"

    U.S. Energy Information Administration (EIA) Indexed Site

    012015 7:00:34 AM" "Back to Contents","Data 1: U.S. Underground Natural Gas Storage Capacity" "Sourcekey","N5290US2","NA1393NUS2","NA1392NUS2","NA1391NUS2","NGAEP...

  17. Nitrogen expander cycles for large capacity liquefaction of natural gas

    SciTech Connect (OSTI)

    Chang, Ho-Myung; Park, Jae Hoon; Gwak, Kyung Hyun; Choe, Kun Hyung

    2014-01-29

    Thermodynamic study is performed on nitrogen expander cycles for large capacity liquefaction of natural gas. In order to substantially increase the capacity, a Brayton refrigeration cycle with nitrogen expander was recently added to the cold end of the reputable propane pre-cooled mixed-refrigerant (C3-MR) process. Similar modifications with a nitrogen expander cycle are extensively investigated on a variety of cycle configurations. The existing and modified cycles are simulated with commercial process software (Aspen HYSYS) based on selected specifications. The results are compared in terms of thermodynamic efficiency, liquefaction capacity, and estimated size of heat exchangers. The combination of C3-MR with partial regeneration and pre-cooling of nitrogen expander cycle is recommended to have a great potential for high efficiency and large capacity.

  18. Saudi production capacity climbing to 10 million b/d

    SciTech Connect (OSTI)

    Not Available

    1994-07-11

    Saudi Arabia this year is completing its expansion of production capacity and developing recent discoveries to enhance export flexibility. The 3 million b/d capacity expansion to 10 million b/d, announced in 1989, is on target for completion by year end 1994. Most of the effort involves restoration of mothballed production equipment and installation of several gas-oil separation plants (GOSPs) in existing fields. But Saudi Arabian Oil Co. (Saudi Aramco) also this year will start up production of extra-light oil from a new field in the central part of the kingdom. Start-up of Hawtah area production demonstrates success of an oil search Aramco began after receiving exclusive exploration rights to nearly all of Saudi Arabia's prospective area in 1986. From new fields and traditional producing areas, therefore, Saudi Arabia has the potential to expand production capacity beyond 10 million b/d. The paper describes the development of the extra capacity.

  19. On the Capacity of Cognitive Relay assisted Gaussian Interference Channel

    E-Print Network [OSTI]

    Jafar, Syed A.

    On the Capacity of Cognitive Relay assisted Gaussian Interference Channel Sriram Sridharan, Sriram: srid- hara@ece.utexas.edu; sriram@ece.utexas.edu). S. Sridharan and S. Vish- wanath are supported

  20. On the Capacity of Vector Gaussian Interference Channels Sriram Vishwanath

    E-Print Network [OSTI]

    Jafar, Syed A.

    On the Capacity of Vector Gaussian Interference Channels Sriram Vishwanath Electrical and Computer Engineering Univ. of Texas at Austin, Austin, TX 78712 e-mail: sriram@ece.utexas.edu Syed Ali Jafar Electrical

  1. Capacity planning and change management in an aerospace overhaul cell

    E-Print Network [OSTI]

    Walker, David, M.B.A. Massachusetts Institute of Technology

    2013-01-01

    Purpose - This thesis analyzes the transformation of the Small Components Cell in Pratt & Whitney's aftermarket division through lean manufacturing techniques. The thesis focuses on use of a labor capacity planning model, ...

  2. Dynamics of social contagions with limited contact capacity

    E-Print Network [OSTI]

    Wang, Wei; Zhu, Yu-Xiao; Tang, Ming; Zhang, Yi-Cheng

    2015-01-01

    Individuals are always limited by some inelastic resources, such as time and energy, which restrict them to dedicate to social interaction and limit their contact capacity. Contact capacity plays an important role in dynamics of social contagions, which so far has eluded theoretical analysis. In this paper, we first propose a non-Markovian model to understand the effects of contact capacity on social contagions, in which each individual can only contact and transmit the information to a finite number of neighbors. We then develop a heterogeneous edge-based compartmental theory for this model, and a remarkable agreement with simulations is obtained. Through theory and simulations, we find that enlarging the contact capacity makes the network more fragile to behavior spreading. Interestingly, we find that both the continuous and discontinuous dependence of the final adoption size on the information transmission probability can arise. And there is a crossover phenomenon between the two types of dependence. More ...

  3. Prediction of Heat Capacities of Solid Inorganic Salts from Group

    Office of Scientific and Technical Information (OSTI)

    Prediction of Heat Capacities of Solid Inorganic Salts from Group Contributions. )&-SUB -- 7 5- g 7 A. T. M. Golam Mostafa, James M. Eakman* Department of Chemical Engineering New...

  4. High capacity stabilized complex hydrides for hydrogen storage

    DOE Patents [OSTI]

    Zidan, Ragaiy; Mohtadi, Rana F; Fewox, Christopher; Sivasubramanian, Premkumar

    2014-11-11

    Complex hydrides based on Al(BH.sub.4).sub.3 are stabilized by the presence of one or more additional metal elements or organic adducts to provide high capacity hydrogen storage material.

  5. Real options approach to capacity planning under uncertainty

    E-Print Network [OSTI]

    Mittal, Geetanjali, 1979-

    2004-01-01

    This thesis highlights the effectiveness of Real Options Analysis (ROA) in capacity planning decisions for engineering projects subject to uncertainty. This is in contrast to the irreversible decision-making proposed by ...

  6. Creative capacity building in post-conflict Uganda

    E-Print Network [OSTI]

    Taha, Kofi A. (Kofi Abdul Malik)

    2011-01-01

    Creative Capacity Building (CCB) is a methodology that emphasizes the ability of people living in poverty to create livelihood technologies, i.e., machines and tools that increase income, improve health and safety, decrease ...

  7. Capacity Requirements to Support Inter-Balancing Area Wind Delivery

    SciTech Connect (OSTI)

    Kirby, B.; Milligan, M.

    2009-07-01

    Paper examines the capacity requirements that arise as wind generation is integrated into the power system and how those requirements change depending on where the wind energy is delivered.

  8. Why Are We Talking About Capacity Markets? (Presentation)

    SciTech Connect (OSTI)

    Milligan, M.

    2011-06-01

    Capacity markets represent a new and novel way to achieve greater economic use of variable generation assets such as wind and solar, and this concept is discussed in this presentation.

  9. ,"U.S. Underground Natural Gas Storage Capacity"

    U.S. Energy Information Administration (EIA) Indexed Site

    012015 7:00:34 AM" "Back to Contents","Data 1: U.S. Underground Natural Gas Storage Capacity" "Sourcekey","N5290US2","NGAEPG0SACW0NUSMMCF","NA1394NUS8"...

  10. Quantum Mutual Information Capacity for High-Dimensional Entangled States

    E-Print Network [OSTI]

    Dixon, P. Ben

    High-dimensional Hilbert spaces used for quantum communication channels offer the possibility of large data transmission capabilities. We propose a method of characterizing the channel capacity of an entangled photonic ...

  11. Evaluating the impact of interventions on network capacity

    E-Print Network [OSTI]

    Rapolu, Sujith Reddy

    2010-01-01

    Analyzing the capacity impact of different diverse interventions on the network is essential in understanding the causes of congestion. In this thesis, a framework to understand the effects of different disruption events ...

  12. SEISMIC CAPACITY OF THREADED, BRAZED AND GROOVED PIPE JOINTS

    Office of Energy Efficiency and Renewable Energy (EERE)

    Seismic Capacity of Threaded, Brazed and Grooved Pipe Joints Brent Gutierrez, PhD, PE George Antaki, PE, F.ASME DOE NPH Conference October 25-26, 2011

  13. High-Rate, High-Capacity Binder-Free Electrode

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    that this process could be employed for any high-volume expansion material. * Volumetric capacity at 1C is 2000 mAhcm 3 (3 x graphite). Commercial Fe 3 O 4 material works...

  14. Development of operations based long range network capacity planning models

    E-Print Network [OSTI]

    Wilson, Cynthia M. (Cynthia Marie)

    2011-01-01

    Planning for vaccines manufacturing capacity is both a complex task requiring many inputs and an important function of manufacturers to ensure the supply of vaccines that prevent life-threatening illnesses. This thesis ...

  15. Tri-Laboratory Linux Capacity Cluster 2007 SOW

    SciTech Connect (OSTI)

    Seager, M

    2007-03-22

    The Advanced Simulation and Computing (ASC) Program (formerly know as Accelerated Strategic Computing Initiative, ASCI) has led the world in capability computing for the last ten years. Capability computing is defined as a world-class platform (in the Top10 of the Top500.org list) with scientific simulations running at scale on the platform. Example systems are ASCI Red, Blue-Pacific, Blue-Mountain, White, Q, RedStorm, and Purple. ASC applications have scaled to multiple thousands of CPUs and accomplished a long list of mission milestones on these ASC capability platforms. However, the computing demands of the ASC and Stockpile Stewardship programs also include a vast number of smaller scale runs for day-to-day simulations. Indeed, every 'hero' capability run requires many hundreds to thousands of much smaller runs in preparation and post processing activities. In addition, there are many aspects of the Stockpile Stewardship Program (SSP) that can be directly accomplished with these so-called 'capacity' calculations. The need for capacity is now so great within the program that it is increasingly difficult to allocate the computer resources required by the larger capability runs. To rectify the current 'capacity' computing resource shortfall, the ASC program has allocated a large portion of the overall ASC platforms budget to 'capacity' systems. In addition, within the next five to ten years the Life Extension Programs (LEPs) for major nuclear weapons systems must be accomplished. These LEPs and other SSP programmatic elements will further drive the need for capacity calculations and hence 'capacity' systems as well as future ASC capability calculations on 'capability' systems. To respond to this new workload analysis, the ASC program will be making a large sustained strategic investment in these capacity systems over the next ten years, starting with the United States Government Fiscal Year 2007 (GFY07). However, given the growing need for 'capability' systems as well, the budget demands are extreme and new, more cost effective ways of fielding these systems must be developed. This Tri-Laboratory Linux Capacity Cluster (TLCC) procurement represents the ASC first investment vehicle in these capacity systems. It also represents a new strategy for quickly building, fielding and integrating many Linux clusters of various sizes into classified and unclassified production service through a concept of Scalable Units (SU). The programmatic objective is to dramatically reduce the overall Total Cost of Ownership (TCO) of these 'capacity' systems relative to the best practices in Linux Cluster deployments today. This objective only makes sense in the context of these systems quickly becoming very robust and useful production clusters under the crushing load that will be inflicted on them by the ASC and SSP scientific simulation capacity workload.

  16. Flood control reservoir operations for conditions of limited storage capacity 

    E-Print Network [OSTI]

    Rivera Ramirez, Hector David

    2005-02-17

    -1 FLOOD CONTROL RESERVOIR OPERATIONS FOR CONDITIONS OF LIMITED STORAGE CAPACITY A Dissertation by HECTOR DAVID RIVERA RAMIREZ Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment... of the requirements for the degree of DOCTOR OF PHILOSOPHY December 2004 Major Subject: Civil Engineering FLOOD CONTROL RESERVOIR OPERATIONS FOR CONDITIONS OF LIMITED STORAGE CAPACITY A Dissertation by HECTOR DAVID RIVERA...

  17. Capacity with energy constraint in coherent state channel

    E-Print Network [OSTI]

    Masahito Hayashi

    2009-04-02

    We consider two kind of energy constraints when the output state is a coherent state. One is a constraint on the total energy during a fixed period; the other is a constraint on the total energy for a single code. The first setting can be easily dealt with by using the conventional capacity formula. The second setting requires the general capacity formula for a classical-quantum channel.

  18. Classical capacity of Gaussian communication under a single noisy channel

    E-Print Network [OSTI]

    Jaehak Lee; Se-Wan Ji; Jiyong Park; Hyunchul Nha

    2015-05-06

    A long-standing problem on the classical capacity of bosonic Gaussian channels has recently been resolved by proving the minimum output entropy conjecture. It is also known that the ultimate capacity quantified by the Holevo bound can be achieved asymptotically by using an infinite number of channels. However, it is less understood to what extent the communication capacity can be reached if one uses a finite number of channels, which is a topic of practical importance. In this paper, we study the capacity of Gaussian communication, i.e., employing Gaussian states and Gaussian measurements to encode and decode information under a single-channel use. We prove that the optimal capacity of single-channel Gaussian communication is achieved by one of two well-known protocols, i.e., coherent-state communication or squeezed-state communication, depending on the energy (number of photons) as well as the characteristics of the channel. Our result suggests that the coherent-state scheme known to achieve the ultimate information-theoretic capacity is not a practically optimal scheme for the case of using a finite number of channels. We find that overall the squeezed-state communication is optimal in a small-photon-number regime whereas the coherent-state communication performs better in a large-photon-number regime.

  19. Water holding capacities of fly ashes: Effect of size fractionation

    SciTech Connect (OSTI)

    Sarkar, A.; Rano, R.

    2007-07-01

    Water holding capacities of fly ashes from different thermal power plants in Eastern India have been compared. Moreover, the effect of size fractionation (sieving) on the water holding capacities has also been determined. The desorption rate of water held by the fly ash fractions at ambient temperature (25-30{sup o}C) has been investigated. The effect of mixing various size fractions of fly ash in increasing the water holding capacities of fly ash has been studied. It is observed that the fly ash obtained from a thermal power plant working on stoker-fired combustor has the highest water holding capacity, followed by the one that works on pulverized fuel combustor. Fly ash collected from super thermal power plant has the least water holding capacity (40.7%). The coarser size fractions of fly ashes in general have higher water holding capacities than the finer ones. An attempt has been made to correlate the results obtained, with the potential use in agriculture.

  20. Using Dimmable Lighting for Regulation Capacity and Non-Spinning Reserves in the Ancillary Services Market. A Feasibility Study.

    SciTech Connect (OSTI)

    Rubinstein, Francis; Xiaolei, Li; Watson, David S.

    2010-12-03

    The objective of this Feasibility Study was to identify the potential of dimmable lighting for providing regulation capacity and contingency reserves if massively-deployed throughout the State. We found that one half of the total electric lighting load in the California commercial sector is bottled up in larger buildings that are greater an 50,000 square feet. Retrofitting large California buildings with dimmable lighting to enable fast DR lighting would require an investment of about $1.8 billion and a"fleet" of about 56 million dimming ballasts. By upgrading the existing installed base of lighting and controls (primarily in large commercial facilities) a substantial amount of ancillary services could be provided. Though not widely deployed, today's state-of-the art lighting systems, control systems and communication networks could be used for this application. The same lighting control equipment that is appropriate for fast DR is also appropriate for achieving energy efficiency with lighting on a daily basis. Thus fast DR can leverage the capabilities that are provided by a conventional dimming lighting control system. If dimmable lighting were massively deployed throughout large California buildings (because mandated by law, for example) dimmable lighting could realistically supply 380 MW of non-spinning reserve, 47percent of the total non-spinning reserves needed in 2007.

  1. Toxecon Retrofit for Mercury and Mulit-Pollutant Control on Three 90-MW Coal-Fired Boilers

    SciTech Connect (OSTI)

    Steven Derenne; Robin Stewart

    2009-09-30

    This U.S. Department of Energy (DOE) Clean Coal Power Initiative (CCPI) project was based on a cooperative agreement between We Energies and the DOE Office of Fossil Energy's National Energy Technology Laboratory (NETL) to design, install, evaluate, and demonstrate the EPRI-patented TOXECON{trademark} air pollution control process. Project partners included Cummins & Barnard, ADA-ES, and the Electric Power Research Institute (EPRI). The primary goal of this project was to reduce mercury emissions from three 90-MW units that burn Powder River Basin coal at the We Energies Presque Isle Power Plant in Marquette, Michigan. Additional goals were to reduce nitrogen oxide (NO{sub x}), sulfur dioxide (SO{sub 2}), and particulate matter emissions; allow reuse and sale of fly ash; advance commercialization of the technology; demonstrate a reliable mercury continuous emission monitor (CEM) suitable for use at power plants; and demonstrate recovery of mercury from the sorbent. Mercury was controlled by injection of activated carbon upstream of the TOXECON{trademark} baghouse, which achieved more than 90% removal on average over a 44-month period. During a two-week test involving trona injection, SO{sub 2} emissions were reduced by 70%, although no coincident removal of NOx was achieved. The TOXECON{trademark} baghouse also provided enhanced particulate control, particularly during startup of the boilers. On this project, mercury CEMs were developed and tested in collaboration with Thermo Fisher Scientific, resulting in a reliable CEM that could be used in the power plant environment and that could measure mercury as low as 0.1 {micro}g/m{sup 3}. Sorbents were injected downstream of the primary particulate collection device, allowing for continued sale and beneficial use of captured fly ash. Two methods for recovering mercury using thermal desorption on the TOXECON{trademark} PAC/ash mixture were successfully tested during this program. Two methods for using the TOXECON{trademark} PAC/ash mixture in structural concrete were also successfully developed and tested. This project demonstrated a significant reduction in the rate of emissions from Presque Isle Units 7, 8, and 9, and substantial progress toward establishing the design criteria for one of the most promising mercury control retrofit technologies currently available. The Levelized Cost for 90% mercury removal at this site was calculated at $77,031 per pound of mercury removed with a capital cost of $63,189 per pound of mercury removed. Mercury removal at the Presque Isle Power Plant averages approximately 97 pounds per year.

  2. Solar Adoption and Energy Consumption in the Residential Sector

    E-Print Network [OSTI]

    McAllister, Joseph Andrew

    2012-01-01

    400 MW of installed solar electric capacity on new homes,were 165 MW of solar capacity installed; capacity more than

  3. March 25 Webinar to Focus on Building Tribal Capacity to Deploy...

    Energy Savers [EERE]

    Webinar to Focus on Building Tribal Capacity to Deploy Strategic Energy Plans and Guide Project Development Decisions March 25 Webinar to Focus on Building Tribal Capacity to...

  4. LG to DOE General Counsel; Re:Request for Comment on Large Capacity...

    Energy Savers [EERE]

    Capacity Clothes Washers LG response to DOE's request for information regarding alternative test procedures for large-capacity clothes washer models, December 7, 2010. After...

  5. Expansion of Michigan EOR Operations Using Advanced Amine Technology at a 600 MW Project Wolverine Carbon Capture and Storage Project

    SciTech Connect (OSTI)

    H Hoffman; Y kishinevsky; S. Wu; R. Pardini; E. Tripp; D. Barnes

    2010-06-16

    Wolverine Power Supply Cooperative Inc, a member owned cooperative utility based in Cadillac Michigan, proposes to demonstrate the capture, beneficial utilization and storage of CO{sub 2} in the expansion of existing Enhanced Oil Recovery operations. This project is being proposed in response to the US Department of Energy Solicitation DE-FOA-0000015 Section III D, 'Large Scale Industrial CCS projects from Industrial Sources' Technology Area 1. The project will remove 1,000 metric tons per day of CO{sub 2} from the Wolverine Clean Energy Venture 600 MW CFB power plant owned and operated by WPC. CO{sub 2} from the flue gas will be captured using Hitachi's CO{sub 2} capture system and advanced amine technology. The capture system with the advanced amine-based solvent supplied by Hitachi is expected to significantly reduce the cost and energy requirements of CO{sub 2} capture compared to current technologies. The captured CO{sub 2} will be compressed and transported for Enhanced Oil Recovery and CO{sub 2} storage purposes. Enhanced Oil Recovery is a proven concept, widely used to recover otherwise inaccessible petroleum reserves. While post-combustion CO{sub 2} capture technologies have been tested at the pilot scale on coal power plant flue gas, they have not yet been demonstrated at a commercial scale and integrated with EOR and storage operations. Amine-based CO{sub 2} capture is the leading technology expected to be available commercially within this decade to enable CCS for utility and industrial facilities firing coal and waste fuels such as petroleum coke. However, traditional CO{sub 2} capture process utilizing commercial amine solvents is very energy intensive for regeneration and is also susceptible to solvent degradation by oxygen as well as SOx and NO{sub 2} in the flue gas, resulting in large operating costs. The large volume of combustion flue gas with its low CO{sub 2} concentration requires large equipment sizes, which together with the highly corrosive nature of the typical amine-based separation process leads to high plant capital investment. According to recent DOE-NETL studies, MEA-based CCS will increase the cost of electricity of a new pulverized coal plant by 80-85% and reduce the net plant efficiency by about 30%. Non-power industrial facilities will incur similar production output and efficiency penalties when implementing conventional carbon capture systems. The proposed large scale demonstration project combining advanced amine CO{sub 2} capture integrated with commercial EOR operations significantly advances post-combustion technology development toward the DOE objectives of reducing the cost of energy production and improving the efficiency of CO{sub 2} Capture technologies. WPC has assembled a strong multidisciplinary team to meet the objectives of this project. WPC will provide the host site and Hitachi will provide the carbon capture technology and advanced solvent. Burns and Roe bring expertise in overall engineering integration and plant design to the team. Core Energy, an active EOR producer/operator in the State of Michigan, is committed to support the detailed design, construction and operation of the CO{sub 2} pipeline and storage component of the project. This team has developed a Front End Engineering Design and Cost Estimate as part of Phase 1 of DOE Award DE-FE0002477.

  6. Plug and Process Loads Capacity and Power Requirements Analysis

    SciTech Connect (OSTI)

    Sheppy, M.; Gentile-Polese, L.

    2014-09-01

    This report addresses gaps in actionable knowledge that would help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. Limited initial data, however, suggest that actual PPL densities in leased buildings are substantially lower. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems. Better guidance will enable improved sizing and design of these systems, decrease upfront capital costs, and allow systems to operate more energy efficiently. The main focus of this report is to provide industry with reliable, objective third-party guidance to address the information gap in typical PPL densities for commercial building tenants. This could drive changes in negotiations about PPL energy demands.

  7. Optimal Encoding Capacity of a Linear Optical Quantum Channel

    E-Print Network [OSTI]

    Jake A. Smith; Dmitry B. Uskov; Lev Kaplan

    2015-08-10

    Here, we study the capacity of a quantum channel, assuming linear optical encoding, as a function of available photons and optical modes. First, we observe that substantial improvement is made possible by not restricting ourselves to a rail-encoded qubit basis. Then, we derive an analytic formula for general channel capacity and show that this capacity is achieved without requiring the use of entangling operations typically required for scalable universal quantum computation, e.g. KLM measurement-assisted transformations. As an example, we provide an explicit encoding scheme using the resources required of standard dense coding using two dual-rail qubits (2 photons in 4 modes). In this case, our protocol encodes one additional bit of information. Greater gains are expected for larger systems.

  8. Bounds on the outage-constrained capacity region of space-division multiple-access radio systems

    E-Print Network [OSTI]

    Jin, Haipeng; Acampora, A

    2004-01-01

    Broadcast Channels - Part I: Outage Capacity,” IEEE Trans.Bounds on the Outage-Constrained Capacity Region of Spacethe capacity limit as an outage region rates contained

  9. Niland development project geothermal loan guaranty: 49-MW (net) power plant and geothermal well field development, Imperial County, California: Environmental assessment

    SciTech Connect (OSTI)

    Not Available

    1984-10-01

    The proposed federal action addressed by this environmental assessment is the authorization of disbursements under a loan guaranteed by the US Department of Energy for the Niland Geothermal Energy Program. The disbursements will partially finance the development of a geothermal well field in the Imperial Valley of California to supply a 25-MW(e) (net) power plant. Phase I of the project is the production of 25 MW(e) (net) of power; the full rate of 49 MW (net) would be achieved during Phase II. The project is located on approximately 1600 acres (648 ha) near the city of Niland in Imperial County, California. Well field development includes the initial drilling of 8 production wells for Phase I, 8 production wells for Phase II, and the possible need for as many as 16 replacement wells over the anticipated 30-year life of the facility. Activities associated with the power plant in addition to operation are excavation and construction of the facility and associated systems (such as cooling towers). Significant environmental impacts, as defined in Council on Environmental Quality regulation 40 CFR Part 1508.27, are not expected to occur as a result of this project. Minor impacts could include the following: local degradation of ambient air quality due to particulate and/or hydrogen sulfide emissions, temporarily increased ambient noise levels due to drilling and construction activities, and increased traffic. Impacts could be significant in the event of a major spill of geothermal fluid, which could contaminate groundwater and surface waters and alter or eliminate nearby habitat. Careful land use planning and engineering design, implementation of mitigation measures for pollution control, and design and implementation of an environmental monitoring program that can provide an early indication of potential problems should ensure that impacts, except for certain accidents, will be minimized.

  10. Method of increasing the sulfation capacity of alkaline earth sorbents

    DOE Patents [OSTI]

    Shearer, J.A.; Turner, C.B.; Johnson, I.

    1980-03-13

    A system and method for increasing the sulfation capacity of alkaline earth carbonates to scrub sulfur dioxide produced during the fluidized bed combustion of coal in which partially sulfated alkaline earth carbonates are hydrated in a fluidized bed to crack the sulfate coating and convert the alkaline earth oxide to the hydroxide. Subsequent dehydration of the sulfate-hydroxide to a sulfate-oxide particle produces particles having larger pore size, increased porosity, decreased grain size and additional sulfation capacity. A continuous process is disclosed.

  11. Capacity Proportional Unstructured Peer-to-Peer Networks 

    E-Print Network [OSTI]

    Reddy, Chandan Rama

    2010-10-12

    stream_source_info REDDY-THESIS.pdf.txt stream_content_type text/plain stream_size 69931 Content-Encoding ISO-8859-1 stream_name REDDY-THESIS.pdf.txt Content-Type text/plain; charset=ISO-8859-1 CAPACITY-PROPORTIONAL... CAPACITY-PROPORTIONAL UNSTRUCTURED PEER-TO-PEER NETWORKS A Thesis by CHANDAN RAMA REDDY Submitted to the O?ce of Graduate Studies of Texas A&M University in partial fulflllment of the requirements for the degree of MASTER OF SCIENCE Approved by: Chair...

  12. World nuclear capacity and fuel cycle requirements, November 1993

    SciTech Connect (OSTI)

    Not Available

    1993-11-30

    This analysis report presents the current status and projections of nuclear capacity, generation, and fuel cycle requirements for all countries in the world using nuclear power to generate electricity for commercial use. Long-term projections of US nuclear capacity, generation, fuel cycle requirements, and spent fuel discharges for three different scenarios through 2030 are provided in support of the Department of Energy`s activities pertaining to the Nuclear Waste Policy Act of 1982 (as amended in 1987). The projections of uranium requirements also support the Energy Information Administration`s annual report, Domestic Uranium Mining and Milling Industry: Viability Assessment.

  13. High-Capacity Sulfur Dioxide Absorbents for Diesel Emissions Control

    SciTech Connect (OSTI)

    Li, Liyu; King, David L.

    2005-01-05

    High capacity sulfur dioxide absorbents based on manganese oxide octahedral molecular sieves (OMS) have been identified. These materials are based on MnO6 octahedra sharing faces and edges to form various tunnel structures (2x2, 2x3, 2x4, 3x3) differentiated by the number of octahedra on a side. The SO2 capacities of these materials, measured at 325 C with a feed containing 250 ppmv SO2 in air, are as high as 70wt% (wt/wt), remarkably higher than conventional metal oxide-based SO2 absorbents. Among the OMS materials the 2x2 member, cryptomelane, exhibits the highest capacity and adsorption rate. Its SO2 absorption behavior has been further characterized as a function of temperature, space velocity, and feed composition. The dominant pathway for SO2 absorption is through the oxidation of SO2 to SO3 by Mn4+ followed by SO3 reaction with Mn2+ to form MnSO4. Absorption can occur in the absence of gas phase oxygen, with a moderate loss in overall capacity. The inclusion of reducible gases NO and CO in the feed does not reduce SO2 capacity. The absorption capacity decreases at high space velocity and lower absorption temperature, indicating the important role of diffusion of sulfate from the surface to the bulk of the material in order to reach full capacity. A color change of cryptomelane from black to yellow-brown after SO2 absorption can be used as an indicator of absorption progress. Cryptomelane can be synthesized using MnSO4 as a reagent. Therefore, after full SO2 absorption the product MnSO4 can be re-used as raw material for a subsequent cryptomelane synthesis. Cryptomelane has a similarly high capacity toward SO3, therefore it can be used for removal of all SOx species generated from a variety of combustion sources. Cryptomelane may find application as a replaceable absorbent for the removal of SOx from diesel truck exhaust, protecting downstream emissions control devices such as particulate filters and NOx traps.

  14. Cross sections for singlyprotonated peptides from tryptic digests a residues Assigned sequence b Peptide source c MW d Cross section ( 2 ) e

    E-Print Network [OSTI]

    Clemmer, David E.

    sequence b Peptide source c MW d Cross section (Å 2 ) e Number of measurements f 2 AK gludehy_bov 217.28 87.01 1 2 AR lactotrans_bov 245.29 93.79 1 2 EK albu_pig 275.31 97.89 (1.14) 9.74 (1.00) 3 HSA 2 FR canhyd_bov 321.39 111.10 (0.03) 2 2 HK cytc_horse 283.30 98.96 (0

  15. Kemper County IGCC (tm) Project Preliminary Public Design Report

    SciTech Connect (OSTI)

    Nelson, Matt; Rush, Randall; Madden, Diane; Pinkston, Tim; Lunsford, Landon

    2012-07-01

    The Kemper County IGCC Project is an advanced coal technology project that is being developed by Mississippi Power Company (MPC). The project is a lignite-fueled 2-on-1 Integrated Gasification Combined-Cycle (IGCC) facility incorporating the air-blown Transport Integrated Gasification (TRIG™) technology jointly developed by Southern Company; Kellogg, Brown, and Root (KBR); and the United States Department of Energy (DOE) at the Power Systems Development Facility (PSDF) in Wilsonville, Alabama. The estimated nameplate capacity of the plant will be 830 MW with a peak net output capability of 582 MW. As a result of advanced emissions control equipment, the facility will produce marketable byproducts of ammonia, sulfuric acid, and carbon dioxide. 65 percent of the carbon dioxide (CO{sub 2}) will be captured and used for enhanced oil recovery (EOR), making the Kemper County facility’s carbon emissions comparable to those of a natural-gas-fired combined cycle power plant. The commercial operation date (COD) of the Kemper County IGCC plant will be May 2014. This report describes the basic design and function of the plant as determined at the end of the Front End Engineering Design (FEED) phase of the project.

  16. On the Throughput Capacity of Heterogeneous Wireless Networks

    E-Print Network [OSTI]

    Latchman, Haniph A.

    On the Throughput Capacity of Heterogeneous Wireless Networks Pan Li, Member, IEEE, and Yuguang of wireless networks. However, it is commonly assumed that all nodes in the network are identical. The issue of heterogeneous wireless networks with general network settings. Specifically, we consider an extended network

  17. Predicting Operator Capacity for Supervisory Control of Multiple UAVs

    E-Print Network [OSTI]

    Cummings, Mary "Missy"

    Predicting Operator Capacity for Supervisory Control of Multiple UAVs M.L. Cummings, C. E. Nehme, J, uninhabited (also known as unmanned) ae- rial vehicles (UAVs) have become indispensable assets to militarized forces. UAVs require human guidance to varying degrees and often through several operators. However

  18. : Measurement of Battery Capacity in Mobile Robot Systems

    E-Print Network [OSTI]

    Breu, Ruth

    . These enhancements pose demanding operation conditions on the battery, emphasizing the importance of this com- ponentRoBM2 : Measurement of Battery Capacity in Mobile Robot Systems Nestor Lucas1 , Cosmin Codrea1. With battery driven robot systems performing very sophisti- cated tasks, increasing demands on the power supply

  19. Solar Photovoltaic Capacity F t P f d P li

    E-Print Network [OSTI]

    6/19/2013 1 Solar Photovoltaic ­ Capacity F t P f d P li Generating Resources Advisory Committee Advisor Model (SAM), version 2013.1.15 Technology: Solar PV (PVWatts system model)Technology: Solar PV (MWh) (First year output, each year thereafter degrades 0.5%) 6 #12;6/19/2013 4 Shape of PNW Solar PV

  20. Achievable Transmission Capacity of Cognitive Radio Networks with Cooperative Relaying

    E-Print Network [OSTI]

    Cheng, Xiuzhen "Susan"

    Achievable Transmission Capacity of Cognitive Radio Networks with Cooperative Relaying Xiuying Chen, Washington DC, USA 3VTT - Technical Research Centre of Finland, Kaitov¨ayl¨a 1, Oulu, Finland {10120069,tjing that secondary users can only work under a low transmission power condition in an underlay spectrum sharing model

  1. Capacity planning in a transitional economy: What issues? Which models?

    SciTech Connect (OSTI)

    Mubayi, V.; Leigh, R.W.; Bright, R.N.

    1996-03-01

    This paper is devoted to an exploration of the important issues facing the Russian power generation system and its evolution in the foreseeable future and the kinds of modeling approaches that capture those issues. These issues include, for example, (1) trade-offs between investments in upgrading and refurbishment of existing thermal (fossil-fired) capacity and safety enhancements in existing nuclear capacity versus investment in new capacity, (2) trade-offs between investment in completing unfinished (under construction) projects based on their original design versus investment in new capacity with improved design, (3) incorporation of demand-side management options (investments in enhancing end-use efficiency, for example) within the planning framework, (4) consideration of the spatial dimensions of system planning including investments in upgrading electric transmission networks or fuel shipment networks and incorporating hydroelectric generation, (5) incorporation of environmental constraints and (6) assessment of uncertainty and evaluation of downside risk. Models for exploring these issues include low power shutdown (LPS) which are computationally very efficient, though approximate, and can be used to perform extensive sensitivity analyses to more complex models which can provide more detailed answers but are computationally cumbersome and can only deal with limited issues. The paper discusses which models can usefully treat a wide range of issues within the priorities facing decision makers in the Russian power sector and integrate the results with investment decisions in the wider economy.

  2. Capacities and Research in Homeland Security The University at Buffalo

    E-Print Network [OSTI]

    Krovi, Venkat

    , and Biophotonics (ILPB) and the Center for Spin Effects and Quantum Information in Nanostructures (CSEQuIN) conduct multidisciplinary science and technology programs focusing on the development of: (1) high capacity data storage devices for "smart sensor" systems to detect biological and chemical agents. These research directions

  3. Wireless Network Capacity Management: A Real Options Approach

    E-Print Network [OSTI]

    Forsyth, Peter A.

    Wireless Network Capacity Management: A Real Options Approach Y. d'Halluin , P.A. Forsyth , and K factor algorithm is developed, based on a real options formulation. Numerical examples are provided to illustrate various aspects of the model. Keywords: real options, optimal network planning decisions, network

  4. High Capacity Graphite Anodes for Li-Ion battery applications

    E-Print Network [OSTI]

    Popov, Branko N.

    High Capacity Graphite Anodes for Li-Ion battery applications using Tin microencapsulation Basker range 1.6V to 0.01V at 0.05 mV/s Physical characterization SEM, EDAX and XRD #12;SEM images of Bare

  5. Zero Capacity Region of Multidimensional Run Length Constraints

    E-Print Network [OSTI]

    Zeger, Kenneth

    there are at least consecutive zeros. An -dimensional pattern of zeros and ones arranged in an hyper For integers and satisfying , a binary sequence is said to satisfy a one-dimensional run length constraint. For , the -dimensional -constrained capacity is defined as where denotes the number of -dimensional binary rectangular

  6. HUD Community Compass Technical Assistance and Capacity Building Program

    Broader source: Energy.gov [DOE]

    The U.S. Department of Housing and Urban Development (HUD) is accepting applications for approximately $44.9 million for Community Compass, HUD's integrated technical assistance and capacity building initiative. The goal of the initiative is to equip HUD's customers with tools, skills, and knowledge to ensure effective program delivery and efficient stewardship of federal funds.

  7. High capacity nickel battery material doped with alkali metal cations

    DOE Patents [OSTI]

    Jackovitz, John F. (Monroeville, PA); Pantier, Earl A. (Penn Hills, PA)

    1982-05-18

    A high capacity battery material is made, consisting essentially of hydrated Ni(II) hydroxide, and about 5 wt. % to about 40 wt. % of Ni(IV) hydrated oxide interlayer doped with alkali metal cations selected from potassium, sodium and lithium cations.

  8. DHC: a diurnal heat capacity program for microcomputers

    SciTech Connect (OSTI)

    Balcomb, J.D.

    1985-01-01

    A computer program has been developed that can predict the temperature swing in direct gain passive solar buildings. The diurnal heat capacity (DHC) program calculates the DHC for any combination of homogeneous or layered surfaces using closed-form harmonic solutions to the heat diffusion equation. The theory is described, a Basic program listing is provided, and an example solution printout is given.

  9. COMPOSITES AND MANUFACTURED PRODUCTS SCREW-HOLDING CAPACITY OF

    E-Print Network [OSTI]

    , and ness, bending stiffness and strength), wood species (pine vs. sweetgum) had an millworkmarkets nificantly alter the screw-holding capac- els were cut for bending modulus of elas- (screw or nail for the study. This paper (No. 98-22-0213) is published with the approval of the 2AmericanSociety for Testing

  10. Information Capacity of an Energy Harvesting Sensor Node

    E-Print Network [OSTI]

    Viswanath, Pramod

    to electrical energy. Common energy harvesting devices are solar cells, wind turbines and piezo-electric cellsInformation Capacity of an Energy Harvesting Sensor Node R Rajesh, Vinod Sharma and Pramod Viswanath Abstract Energy harvesting sensor nodes are gaining popularity due to their ability to improve

  11. CACM:Current-aware Capacity Management in Consolidated Server Enclosures

    E-Print Network [OSTI]

    Gavrilovska, Ada

    to this study, we suggest the need for `location-aware' methods for load placement and migration. This paperCACM:Current-aware Capacity Management in Consolidated Server Enclosures Hui Chen, Meina Song in electrical current levels across these two domains. This paper describes experiments designed to validate

  12. MFR PAPER 1323 Estimating the Structure of Capacity

    E-Print Network [OSTI]

    MFR PAPER 1323 Estimating the Structure of Capacity Utilization in the Fishing Industry KENNETH and to look at certain types of industry behavior that have been relatively ne- glected. This paper discusses BALLARD and VITO BLOMO INTRODUCTION Research in industrial market struc- ture has usually included

  13. SWING: Traffic Capacity of a Simple WDM Ring Network

    E-Print Network [OSTI]

    Bonald, Thomas

    , Charlotte Roger Orange Labs, France Telecom, France Abstract-- The paper presents a novel MAC protocol. INTRODUCTION There is renewed and growing interest in exploiting the high capacity and energy efficiency result is to prove that a simple greedy opportunistic access policy, while unfair, is perfectly efficient

  14. Analysis of the effect of packing capacity on pork prices 

    E-Print Network [OSTI]

    Spivey, Sarah Elizabeth

    2013-02-22

    In 1998, pork prices fell to an all time low. Across the industry, concern was expressed for research as to what led to this price crash. Capacity constraints at the packer level have been a key area of concern. This study is an analysis...

  15. FISHWAY CAPACITY EXPERIMENT, 1956 iMarine Biological Laboratory!

    E-Print Network [OSTI]

    11 Observations List of capacity tests 11 Effect of changing hydraulics on fish passage 12 over the high costs of fishways and fish protection devices at dams and water diversion projects. As an example, the fish passage facilities at The Dalles Dam, completed in 1957, cost in excess of 18 million

  16. Spent nuclear fuel project design basis capacity study

    SciTech Connect (OSTI)

    Cleveland, K.J.

    1996-09-09

    A parametric study of the Spent Nuclear Fuel Project system capacity is presented. The study was completed using a commercially available software package to develop a summary level model of the major project systems. Alternative configurations, sub-system cycle times, and operating scenarios were tested to identify their impact on total project duration and equipment requirements.

  17. Assessing the Control Systems Capacity for Demand Response in

    E-Print Network [OSTI]

    LBNL-5319E Assessing the Control Systems Capacity for Demand Response in California Industries in this report was coordinated by the Demand Response Research Center and funded by the California Energy of the Demand Response Research Center Industrial Controls Experts Working Group: · Jim Filanc, Southern

  18. Capacity expansion planning of alternative resources Formulation of a new mechanism to

    E-Print Network [OSTI]

    McCalley, James D.

    Capacity expansion planning of alternative resources ­ Formulation of a new mechanism to procure · Gap between net revenues produced by energy markets and the capital costs of investing in new capacity GENERATING CAPACITY, MIT 2006 . FTI Consulting, "Evaluation of the New York Capacity Market", March 2013

  19. Capacity Region, Minimum Energy and Delay for a Mobile Ad-Hoc Network

    E-Print Network [OSTI]

    Chen, Yuanzhu Peter

    Capacity Region, Minimum Energy and Delay for a Mobile Ad-Hoc Network Rahul Urgaonkar, Michael J in a mobile ad-hoc network: the capacity region and the minimum energy function of the network. The capacity limits of a mobile ad-hoc network are the capacity region and the minimum energy function of the network

  20. On the Capacity Region of the Gaussian MAC with Batteryless Energy Harvesting Transmitters

    E-Print Network [OSTI]

    Ulukus, Sennur

    On the Capacity Region of the Gaussian MAC with Batteryless Energy Harvesting Transmitters Omur-user channel capacity with an energy harvesting transmitter of an unlimited battery is equal to the capacity work in [3] and address the capacity region of the Gaussian MAC with batteryless energy harvesting

  1. MSE 3050, Phase Diagrams and Kinetics, Leonid Zhigilei Theoretical calculation of the heat capacity

    E-Print Network [OSTI]

    Zhigilei, Leonid V.

    Principle of equipartition of energy Heat capacity of ideal and real gases Heat capacity of solids: Dulong and internal energy of 3/2kBT. The molar internal energy U=3/2NAkBT=3/2RT and the molar heat capacity under to the heat capacity can be considered classically only if En ~ h Energy leve

  2. Computing Protection Level Policies for Dynamic Capacity Allocation Problems by Using Stochastic Approximation Methods

    E-Print Network [OSTI]

    Topaloglu, Huseyin

    function. However, this approach brings unique challenges in the context of the capacity allocation problemComputing Protection Level Policies for Dynamic Capacity Allocation Problems by Using Stochastic capacity allocation problem. We have a fixed amount of daily processing capacity. Jobs of different

  3. Hydropower Advancement Project (HAP): Audits and Feasibility Studies for Capacity and Efficiency Upgrades

    Office of Energy Efficiency and Renewable Energy (EERE)

    Hydropower Advancement Project (HAP): Audits and Feasibility Studies for Capacity and Efficiency Upgrades

  4. Testing of Supercapacitors: Capacitance, Resistance, and Energy Energy and Power Capacity

    E-Print Network [OSTI]

    Burke, Andrew

    2009-01-01

    and Energy Energy and Power Capacity Andrew Burke Institute of Transportation Studies University of California-

  5. Test and demonstration of a 1-MW wellhead generator: helical screw expander power plant, Model 76-1. Final report to the International Energy Agency

    SciTech Connect (OSTI)

    Not Available

    1985-07-04

    A 1-MW geothermal wellhead power plant incorporating a Lysholm or helical screw expander (HSE) was field tested between 1980 and 1983 by Mexico, Italy, and New Zealand with technical assistance from the United States. The objectives were to provide data on the reliability and performance of the HSE and to assess the costs and benefits of its use. The range of conditions under which the HSE was tested included loads up to 933 kW, mass flowrates of 14,600 to 395, 000 lbs/hr, inlet pressures of 64 to 220 psia, inlet qualities of 0 to 100%, exhaust pressures of 3.1 to 40 psia, total dissolved solids up to 310,000 ppM, and noncondensible gases up to 38% of the vapor mass flow. Typical machine efficiencies of 40 to 50% were calculated. For most operations efficiency increased approximately logarithmically with shaft power, while inlet quality and rotor speed had only small effects. The HSE was designed with oversized internal clearances in the expectation that adherent scale would form during operation. Improvements in machine efficiency of 3.5 to 4 percentage points were observed over some test periods with some scale deposition. A comparison with a 1-MW back-pressure turbine showed that the HSE can compete favorably under certain conditions. The HSE was found to be a rugged energy conversion machine for geothermal applications, but some subsystems were found to require further development. 7 refs., 28 figs., 5 tabs.

  6. Carbon Dioxide Sealing Capacity: Textural or Compositional Controls?

    SciTech Connect (OSTI)

    Cranganu, Constantin; Soleymani, Hamidreza; Sadiqua, Soleymani; Watson, Kieva

    2013-11-30

    This research project is aiming to assess the carbon dioxide sealing capacity of most common seal-rocks, such as shales and non-fractured limestones, by analyzing the role of textural and compositional parameters of those rocks. We hypothesize that sealing capacity is controlled by textural and/or compositional pa-rameters of caprocks. In this research, we seek to evaluate the importance of textural and compositional parameters affecting the sealing capacity of caprocks. The conceptu-al framework involves two testable end-member hypotheses concerning the sealing ca-pacity of carbon dioxide reservoir caprocks. Better understanding of the elements controlling sealing quality will advance our knowledge regarding the sealing capacity of shales and carbonates. Due to relatively low permeability, shale and non-fractured carbonate units are considered relatively imper-meable formations which can retard reservoir fluid flow by forming high capillary pres-sure. Similarly, these unites can constitute reliable seals for carbon dioxide capture and sequestration purposes. This project is a part of the comprehensive project with the final aim of studying the caprock sealing properties and the relationship between microscopic and macroscopic characteristics of seal rocks in depleted gas fields of Oklahoma Pan-handle. Through this study we examined various seal rock characteristics to infer about their respective effects on sealing capacity in special case of replacing reservoir fluid with super critical carbon dioxide (scCO{sub 2}). To assess the effect of textural and compositional properties on scCO{sub 2} maximum reten-tion column height we collected 30 representative core samples in caprock formations in three counties (Cimarron, Texas, Beaver) in Oklahoma Panhandle. Core samples were collected from various seal formations (e.g., Cherokee, Keys, Morrowan) at different depths. We studied the compositional and textural properties of the core samples using several techniques. Mercury Injection Porosimetry (MIP), Scanning Electron Microsco-py SEM, and Sedigraph measurements are used to assess the pore-throat-size distribu-tion, sorting, texture, and grain size of the samples. Also, displacement pressure at 10% mercury saturation (Pd) and graphically derived threshold pressure (Pc) were deter-mined by MIP technique. SEM images were used for qualitative study of the minerals and pores texture of the core samples. Moreover, EDS (Energy Dispersive X-Ray Spec-trometer), BET specific surface area, and Total Organic Carbon (TOC) measurements were performed to study various parameters and their possible effects on sealing capaci-ty of the samples. We found that shales have the relatively higher average sealing threshold pressure (Pc) than carbonate and sandstone samples. Based on these observations, shale formations could be considered as a promising caprock in terms of retarding scCO{sub 2} flow and leak-age into above formations. We hypothesized that certain characteristics of shales (e.g., 3 fine pore size, pore size distribution, high specific surface area, and strong physical chemical interaction between wetting phase and mineral surface) make them an effi-cient caprock for sealing super critical CO{sub 2}. We found that the displacement pressure at 10% mercury saturation could not be the ultimate representative of the sealing capacity of the rock sample. On the other hand, we believe that graphical method, introduced by Cranganu (2004) is a better indicator of the true sealing capacity. Based on statistical analysis of our samples from Oklahoma Panhandle we assessed the effects of each group of properties (textural and compositional) on maximum supercriti-cal CO{sub 2} height that can be hold by the caprock. We conclude that there is a relatively strong positive relationship (+.40 to +.69) between supercritical CO{sub 2} column height based on Pc and hard/ soft mineral content index (ratio of minerals with Mohs hardness more than 5 over minerals with Mohs hardness less than 5) in both shales and limestone samples. Average median pore rad

  7. Design, construction, system integration, and test results of the 1 MW CW RF system for the e-gun cavity in the energy recovery LINAC at Brookhaven National Laboratory

    SciTech Connect (OSTI)

    Lenci,S.J.; Eisen, E. L.; Dickey, D. L.; Sainz, J. E.; Utay, P. F.; Zaltsman, A.; Lambiase, R.

    2009-05-04

    Brookhaven's ERL (Energy Recovery LINAC) requires a 1 MW CW RF system for the superconducting electron gun cavity. The system consists primarily of a klystron tube, transmitter, and High-Voltage Power Supply (HVPS). The 703.75 MHz klystron made by CPl, Inc. provides RF power of 1MW CW with efficiency of 65%. It has a single output window, diode-type electron gun, and collector capable of dissipating the entire beam power. It was fully factory tested including 24-hour heat run at 1.1 MW CWo The solid state HVPS designed by Continental Electronics provides up to 100 kV at low ripple and 2.1 MW CW with over 95% efficiency. With minimal stored energy and a fast shut-down mode no crowbar circuit is needed. Continental 's transmitter includes PLC based user interface and monitoring, RF pre-amplifier, magnet and Vac-Ion pump supplies, cooling water instrumentation, and integral safety interlock system. BNL installed the klystron, HVPS, and transmitter along with other items, such as circulator, water load, and waveguide components. The collaboration of BNL, CPI, and Continental in the design, installation, and testing was essential to the successful operation of the 1MW system.

  8. Hierarchical structures for a robustness-oriented capacity design

    E-Print Network [OSTI]

    Enrico Masoero; Falk K. Wittel; Hans J. Herrmann; B. M. Chiaia

    2015-09-07

    In this paper, we study the response of 2D framed structures made of rectangular cells, to the sudden removal of columns. We employ a simulation algorithm based on the Discrete Element Method, where the structural elements are represented by elasto-plastic Euler Bernoulli beams with elongation-rotation failure threshold. The effect of structural cell slenderness and of topological hierarchy on the dynamic residual strength after damage $\\ROne$ is investigated. Topologically \\textit{hierarchical} frames have a primary structure made of few massive elements, while \\textit{homogeneous} frames are made of many thin elements. We also show how $\\ROne$ depends on the activated collapse mechanisms, which are determined by the mechanical hierarchy between beams and columns, i.e. by their relative strength and stiffness. Finally, principles of robustness-oriented capacity design which seem to be in contrast to the conventional anti-seismic capacity design are addressed.

  9. Hybrid heat capacity-moving slab solid-state laser

    DOE Patents [OSTI]

    Stappaerts, Eddy A.

    2005-03-01

    Laser material is pumped and its stored energy is extracted in a heat capacity laser mode at a high duty factor. When the laser material reaches a maximum temperature, it is removed from the lasing region and a subsequent volume of laser material is positioned into the lasing region to repeat the lasing process. The heated laser material is cooled passively or actively outside the lasing region.

  10. Model documentation: Electricity Market Module, Electricity Capacity Planning submodule

    SciTech Connect (OSTI)

    Not Available

    1994-04-07

    The National Energy Modeling System (NEMS) is a computer modeling system developed by the Energy Information Administration (EIA). The NEMS produces integrated forecasts for energy markets in the United States by achieving a general equilibrium solution for energy supply and demand. Currently, for each year during the period from 1990 through 2010, the NEMS describes energy supply, conversion, consumption, and pricing. The Electricity Market Module (EMM) is the electricity supply component of the National Energy Modeling System (NEMS). The supply of electricity is a conversion activity since electricity is produced from other energy sources (e.g., fossil, nuclear, and renewable). The EMM represents the generation, transmission, and pricing of electricity. The EMM consists of four main submodules: Electricity Capacity Planning (ECP), Electricity Fuel Dispatching (EFD), Electricity Finance and Pricing (EFP), and Load and Demand-Side Management (LDSM). The ECP evaluates changes in the mix of generating capacity that are necessary to meet future demands for electricity and comply with environmental regulations. The EFD represents dispatching (i.e., operating) decisions and determines how to allocate available capacity to meet the current demand for electricity. Using investment expenditures from the ECP and operating costs from the EFD, the EFP calculates the price of electricity, accounting for state-level regulations involving the allocation of costs. The LDSM translates annual demands for electricity into distributions that describe hourly, seasonal, and time-of-day variations. These distributions are used by the EFD and the ECP to determine the quantity and types of generating capacity that are required to insure reliable and economical supplies of electricity. The EMM also represents nonutility suppliers and interregional and international transmission and trade. These activities are included in the EFD and the ECP.

  11. Residential Variable-Capacity Heat Pumps Sized to Heating Loads

    SciTech Connect (OSTI)

    Munk, Jeffrey D.; Jackson, Roderick K.; Odukomaiya, Adewale; Gehl, Anthony C.

    2014-01-01

    Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in the cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.

  12. A global scale mechanistic model of the photosynthetic capacity

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Ali, A. A.; Xu, C.; Rogers, A.; Fisher, R. A.; Wullschleger, S. D.; McDowell, N. G.; Massoud, E. C.; Vrugt, J. A.; Muss, J. D.; Fisher, J. B.; et al

    2015-08-10

    Although plant photosynthetic capacity as determined by the maximum carboxylation rate (i.e., Vc, max25) and the maximum electron transport rate (i.e., Jmax25) at a reference temperature (generally 25 °C) is known to vary substantially in space and time in response to environmental conditions, it is typically parameterized in Earth system models (ESMs) with tabulated values associated to plant functional types. In this study, we developed a mechanistic model of leaf utilization of nitrogen for assimilation (LUNA V1.0) to predict the photosynthetic capacity at the global scale under different environmental conditions, based on the optimization of nitrogen allocated among light capture,more »electron transport, carboxylation, and respiration. The LUNA model was able to reasonably well capture the observed patterns of photosynthetic capacity in view that it explained approximately 55 % of the variation in observed Vc, max25 and 65 % of the variation in observed Jmax25 across the globe. Our model simulations under current and future climate conditions indicated that Vc, max25 could be most affected in high-latitude regions under a warming climate and that ESMs using a fixed Vc, max25 or Jmax25 by plant functional types were likely to substantially overestimate future global photosynthesis.« less

  13. Building Long-Term Sustained Capacity and Influencing Decisions: The U.S. DOE SEP Capacity Model

    SciTech Connect (OSTI)

    McCarthy, Patrick [TecMarket Works; Hall, Nick [TecMarket Works; Schweitzer, Martin [ORNL; Lambert, Faith [U.S. Department of Energy

    2011-01-01

    This paper presents a state-level systems model that incorporates traditional behavior change models into a more extensive framework for explaining energy efficiency and renewable energy impacts. The model was developed from a seminal national study of state energy programs covering a broad array of programmatic topic areas. The study examined a wide range of program offerings within 24 states, involving over 25 years of state efforts. While specific priorities and outcomes varied greatly across the states for each of the topic areas, consistent systems-level capacity-building patterns were revealed. This model demonstrates how the U.S. Department of Energy s (DOE s) State Energy Program (SEP) and non-SEP resources, when incorporated into a framework of essential capacity-building components, can lead to energy efficiency and renewable energy achievements. This paper then features two case study illustrations of the model.

  14. Parameter Estimation and Capacity Fade Analysis of Lithium-Ion Batteries Using Reformulated Models

    E-Print Network [OSTI]

    Braatz, Richard D.

    Many researchers have worked to develop methods to analyze and characterize capacity fade in lithium-ion batteries. As a complement to approaches to mathematically model capacity fade that require detailed understanding ...

  15. The State Energy Program: Building Energy Efficiency and Renewable Energy Capacity in the States

    Office of Energy Efficiency and Renewable Energy (EERE)

    This study documents the capacity-building effects that the federal State Energy Program (SEP) has had on the states' capacity to design, manage and implement energy efficiency and renewable energy programs.

  16. DOE Solicits Views on the Implementation of Large-Capacity Clothes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Large-Capacity Clothes Washer Waivers DOE Solicits Views on the Implementation of Large-Capacity Clothes Washer Waivers November 30, 2010 - 10:56am Addthis The Department of...

  17. Design of a cluster analysis heuristic for the configuration and capacity management of manufacturing cells 

    E-Print Network [OSTI]

    Shim, Young Hak

    2007-09-17

    , the machine capacity was first ensured, and then manufacturing cells were configured to minimize intercellular movements. In order to ensure the machine capacity, the duplication of machines and the split of operations are allowed and operations are assigned...

  18. On the Capacity of the Vector MAC and BC with Feedback

    E-Print Network [OSTI]

    Jafar, Syed A.

    On the Capacity of the Vector MAC and BC with Feedback Syed Ali Jafar Qualcomm Incorporated San to scalar MACs and BCs, respectively. We also determine the capacity enhancement due to feedback at high SNR

  19. Tension capacity of two drilled and grouted piles 

    E-Print Network [OSTI]

    Kubena, Mark Edward

    1989-01-01

    and grouted piles are being proposed as an alternate method for the foundation of deepwater structures. Drilled and grouted piles are composite piles formed by drilling an oversized hole, inserting a smaller steel casing or pile to the bottom of the open...TENSION CAPACITY OF TWO DRILLED AND GROUTED PILES A Thesis by MARK EDWARD KUBENA Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE December 1989...

  20. South Africa-Enhancing Capacity for Low Emission Development Strategies

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page| Open Energy Information Serbia-Enhancing Capacity forSiliciumEnergy Inc JumpPennsylvania:Sound(EC-LEDS) | Open Energy

  1. Property:Geothermal/CapacityBtuHr | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History ViewMayo,AltFuelVehicle2 Jump to: navigation, search This is aAnnualGenGwhYr Jump to:CapacityBtuHr

  2. Property:GrossProdCapacity | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to: navigation,PropertyPartner7Website Jump to:TypeGrossProdCapacity Jump to:

  3. Building REDD Capacity in Developing Countries | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmentalBowerbank, Maine: EnergyEnergyOhio: EnergyNorth Dakota: Energy ResourcesREDD Capacity

  4. Climate Change Capacity Development (C3D+) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTIONRobertsdale, Alabama (Utility Company) Jump to:NewMinnesota: EnergyVirginia: EnergyCapacity

  5. LEDS Capacity Building and Training Inventory | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIXsource History View NewGuam:onItronKanoshKetchikanKlondikeKunBLEDS Capacity Building and

  6. EIA - Natural Gas Pipeline Network - Pipeline Capacity and Utilization

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet) Wyoming Dry NaturalPrices1 Table272/SPipeline Utilization & Capacity About

  7. EIA - Natural Gas Pipeline Network - Region To Region System Capacity

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet) Wyoming Dry NaturalPrices1 Table272/SPipeline Utilization & Capacity

  8. Nitrification Capacities of Texas Soil Types and Factors which Affect Nitrification. 

    E-Print Network [OSTI]

    Sterges, A. J.; Fraps, G S. (George Stronach)

    1947-01-01

    capacities of soils for ammonium sulphate may range from (I to loo percent but additions of bacteria and calcium carbonate will increase the nitrifying capacities of most soils and subsoils to a high extent. Soils with low nitrification capacities have... percent of that of ammonium sulphate, but in >oils of low nitrifying capacity, nitrogen of cottonseed meal may be nitrified more reaclily than that of ammonium sulphate. When the fertilizing values of organic nitrogenous fertilizers are to be compared...

  9. Mexico’s Deteriorating Oil Outlook: Implications and Energy Options for the Future

    E-Print Network [OSTI]

    Shields, David

    2008-01-01

    hydropower dams, several windpower and geothermal projects,only 83 MW of installed windpower capacity, despite havinginstall 2,000 MW or more of windpower capacity annually. If

  10. China Energy Databook -- User Guide and Documentation, Version 7.0

    E-Print Network [OSTI]

    Fridley, Ed., David

    2008-01-01

    Systems Capacity (MW) Small Hydro Capacity (MW) Source:power technologies Small hydro power generation Miicro-hydrois all generation from small hydro stations (rural grids),

  11. China Energy Databook -- User Guide and Documentation, Version 7.0

    E-Print Network [OSTI]

    Fridley, Ed., David

    2008-01-01

    Systems Capacity (MW) Small Hydro Capacity (MW) Source:is all generation from small hydro stations (rural grids),is all generation from small hydro stations (rural grids),

  12. China Energy Databook -- User Guide and Documentation, Version 7.0

    E-Print Network [OSTI]

    Fridley, Ed., David

    2008-01-01

    is all generation from small hydro stations (rural grids),is all generation from small hydro stations (rural grids),Systems Capacity (MW) Small Hydro Capacity (MW) Source:

  13. Ensuring grid reliability in the future -Capacity and Curtailment Issues on the

    E-Print Network [OSTI]

    California at Davis, University of

    in power purchase agreements to reconcile with RPS priorities · Increase energy storage and demand response ­ Trajectory with CEC higher load (3,324MW) forecast · 40% RPS ­ Trajectory with 40% renewable · Expanded Preferred Resources ­ Trajectory with 40% renewable and additional energy efficiency, customer PV

  14. An Analytical Model for Predicting the Remaining Battery Capacity of Lithium-Ion Batteries

    E-Print Network [OSTI]

    Pedram, Massoud

    An Analytical Model for Predicting the Remaining Battery Capacity of Lithium-Ion Batteries Peng cycle-life tends to shrink significantly. The capacities of commercial lithium-ion batteries fade by 10 prediction model to estimate the remaining capacity of a Lithium-Ion battery. The proposed analytical model

  15. Approximation Technique of Finite Capacity Queuing Networks Exploiting Petri Net Analysis

    E-Print Network [OSTI]

    Gribaudo, Marco

    Approximation Technique of Finite Capacity Queuing Networks Exploiting Petri Net Analysis Marco for deriving approximate measures for finite capacity queuing networks. The fact that buffers have finite capacity makes the analysis of such networks very difficult. Indeed, FC-QNs do not have a product form

  16. DETERMINATION OF PHOTOVOLTAIC EFFECTIVE CAPACITY FOR Richard Perez for Clean Power Research

    E-Print Network [OSTI]

    Perez, Richard R.

    DETERMINATION OF PHOTOVOLTAIC EFFECTIVE CAPACITY FOR NEW JERSEY Richard Perez for Clean Power) requirements. #12;DETERMINATION OF PHOTOVOLTAIC EFFECTIVE CAPACITY FOR NEW JERSEY The ELCC metric dispatchable power plant. 2 #12;DETERMINATION OF PHOTOVOLTAIC EFFECTIVE CAPACITY FOR NEW JERSEY 0 1 2 3 4 5 6 7

  17. On Secrecy Outage Capacity of Fading Channels Under Relaxed Delay Constraints

    E-Print Network [OSTI]

    Koksal, Can Emre

    On Secrecy Outage Capacity of Fading Channels Under Relaxed Delay Constraints Onur Gungor, Can Emre delay constraints. More specif- ically, we extend the definition of outage secrecy capacity for single, we provide bounds on secrecy outage capacity with k + 1 block delay constraint. We show

  18. Outage Capacity of the Fading Relay Channel in the Low SNR Regime

    E-Print Network [OSTI]

    Tse, David

    Outage Capacity of the Fading Relay Channel in the Low SNR Regime A. Salman Avestimehr and David N at the outage capacity of the fading relay channel with half-duplex constraint in the low SNR regime. First we. In this case we show that a Bursty Amplify-Forward (BAF) protocol is optimal and achieves the outage capacity

  19. MIMO Outage Capacity in the High SNR Regime Narayan Prasad Mahesh K. Varanasi

    E-Print Network [OSTI]

    Varanasi, Mahesh K.

    MIMO Outage Capacity in the High SNR Regime Narayan Prasad Mahesh K. Varanasi NEC Labs. America channel with coherent reception and pro- vide a sharp characterization of the outage capacity in the form on the outage capacities un- der a long-term and a short-term power constraint as well as on the delay

  20. Sensitivity of Gaussian Channel Capacity and ate-Distortion Function to nonGaussian Contamination

    E-Print Network [OSTI]

    Verdú, Sergio

    Sensitivity of Gaussian Channel Capacity and ate-Distortion Function to nonGaussian Contamination-Gaussian contaminating noise. Although the ca- pacity of such channels cannot be evaluated in general, we analyze the decrease in capacity, or sensitivity of the channel capacity to the weak contaminating noise. We show

  1. Calculation of heat capacities of light and heavy water by path-integral molecular dynamics

    E-Print Network [OSTI]

    Nielsen, Steven O.

    Calculation of heat capacities of light and heavy water by path-integral molecular dynamics 30 September 2005 As an application of atomistic simulation methods to heat capacities, path-integral has estimated the heat capacities too high, the quantum simulation based on path-integral molecular

  2. Capacity Bounds for Energy Efficient Data Streaming in Homogeneous Wireless Ad Hoc Networks

    E-Print Network [OSTI]

    Li, Zongpeng

    Capacity Bounds for Energy Efficient Data Streaming in Homogeneous Wireless Ad Hoc Networks Hanan activation schemes with provable asymptotic bounds on the capacity and energy efficiency of the induced add to the noise levels of each other and cause the overall network capacity to decrease

  3. Capacity of the Energy Harvesting Channel with Energy Arrival Information at the Receiver

    E-Print Network [OSTI]

    Yener, Aylin

    Capacity of the Energy Harvesting Channel with Energy Arrival Information at the Receiver Omur Ozel- pacity is invariant to the non-causal knowledge of energy arrivals. Finally, we show that the capacity the battery energy at the transmitter is independent of the message. The capacity of this channel with only

  4. Behavioral/Systems/Cognitive How the Optic Nerve Allocates Space, Energy Capacity,

    E-Print Network [OSTI]

    Pennsylvania, University of

    Behavioral/Systems/Cognitive How the Optic Nerve Allocates Space, Energy Capacity, and Information twice the space and energy capacity. We conclude that the optic nerve conserves space more spikes. These considerations led us to quantify how space, energy capacity, and firing rate

  5. Energy-efficient Capacity-constrained Routing in Wireless Sensor Networks

    E-Print Network [OSTI]

    Venkatesan, S.

    1 Energy-efficient Capacity-constrained Routing in Wireless Sensor Networks Maulin Patel*, R of packets, which will waste considerable amount of energy. This paper present a Minimum-cost Capacity-hoc networks; Routing; Maximum Lifetime; Energy efficient; Capacity-constrained I. INTRODUCTION Wireless sensor

  6. Towards Achieving Linear Capacity Scaling in Wireless Networks through Directed Energy Links

    E-Print Network [OSTI]

    Misra, Satyajayant

    1 Towards Achieving Linear Capacity Scaling in Wireless Networks through Directed Energy Links Hong-to-linear (CTL) capacity scaling through the use of directed energy (DE) links such as laser communications links have many important applications. However, Gupta and Kumar showed that the capacity of multi

  7. Energy, Latency and Capacity Trade-offs in wireless multi-hop networks

    E-Print Network [OSTI]

    Jaffrès-Runser, Katia

    Energy, Latency and Capacity Trade-offs in wireless multi-hop networks Jean-Marie Gorce, Ruifeng Abstract--This paper concentrates on characterizing energy, latency and capacity trade-offs in multi, our analytical results highlight how the energy/delay Pareto front moves when considering a capacity

  8. Capacity of the Discrete Memoryless Energy Harvesting Channel with Side Information

    E-Print Network [OSTI]

    Yener, Aylin

    Capacity of the Discrete Memoryless Energy Harvesting Channel with Side Information Omur Ozel1 to the available battery energy in that channel use. The capacity of this channel with only transmitter side, The Pennsylvania State University, University Park, PA 16802 Abstract--We determine the capacity of a discrete

  9. The Capacity-Cost Function of Discrete Additive Noise Channels with and without Feedback

    E-Print Network [OSTI]

    Wehlau, David

    of discrete channels with memory. Index Terms { Channels with memory, additive noise, capacity-cost functionThe Capacity-Cost Function of Discrete Additive Noise Channels with and without Feedback #3; Fady by investigating the capacity- cost function (C (#12;)) of such additive noise channels without feedback. We

  10. Energy Efficiency Analysis of MISO-OFDM Communication Systems Considering Power and Capacity Constraints

    E-Print Network [OSTI]

    Wang, Cheng-Xiang

    Energy Efficiency Analysis of MISO-OFDM Communication Systems Considering Power and Capacity subchannel capacity threshold. Moreover, the energy efficiency of MISO-OFDM communication systems starts-input single-output (MISO) . orthogonal frequency division multiplexing (OFDM) . energy efficiency. capacity

  11. A Tractable Revenue Management Model for Capacity Allocation and Overbooking over an Airline Network

    E-Print Network [OSTI]

    Topaloglu, Huseyin

    to the reservations were given by a separable function, then the optimality equation for the joint capacity allocationA Tractable Revenue Management Model for Capacity Allocation and Overbooking over an Airline a revenue management model to jointly make the capacity allocation and overbooking decisions over an airline

  12. Edinburgh Research Explorer ERK2 Suppresses Self-Renewal Capacity of Embryonic Stem

    E-Print Network [OSTI]

    Koehn, Philipp

    Edinburgh Research Explorer ERK2 Suppresses Self-Renewal Capacity of Embryonic Stem Cells, T 2013, 'ERK2 Suppresses Self-Renewal Capacity of Embryonic Stem Cells, but Is Not Required for Multi date: 26. Jun. 2014 #12;ERK2 Suppresses Self-Renewal Capacity of Embryonic Stem Cells

  13. Capacity Planning in a General Supply Chain with Multiple Contract Types Single Period Model

    E-Print Network [OSTI]

    Graves, Stephen C.

    and sufficient capacity to meet market demands. However, capacity planning is a very challenging task for manyCapacity Planning in a General Supply Chain with Multiple Contract Types ­ Single Period Model Xin Huang · Stephen C. Graves Department of Electrical Engineering and Computer Science, Massachusetts

  14. Estimate of Maximum Underground Working Gas Storage Capacity in the United States

    Reports and Publications (EIA)

    2006-01-01

    This report examines the aggregate maximum capacity for U.S. natural gas storage. Although the concept of maximum capacity seems quite straightforward, there are numerous issues that preclude the determination of a definitive maximum volume. The report presents three alternative estimates for maximum capacity, indicating appropriate caveats for each.

  15. Capacity Building in Sharing Forest and Market Information Prague & Krtiny, Czech Republic, 25 October 2005

    E-Print Network [OSTI]

    Capacity Building in Sharing Forest and Market Information Prague & Krtiny, Czech Republic, 25 Specialist UNECE/FAO Timber Branch Geneva, Switzerland #12;Capacity Building in Sharing Forest and Market forest products market information #12;Capacity Building in Sharing Forest and Market Information Prague

  16. IEEE TRANSACTIONS ON INFORMATION THEORY, VOL. 49, NO. 11, NOVEMBER 2003 2895 Capacity and Optimal Power Allocation for Fading

    E-Print Network [OSTI]

    Jindal, Nihar

    of Shannon capacity have been developed for multiuser fading channels: ergodic capacity and outage ca- pacity]­[3], while outage capacity achieves a constant rate in all non-outage fading states subject to an outage probability [4], [5]. Zero-outage capacity refers to outage capacity with zero outage probability [6

  17. Air conditioning system with supplemental ice storing and cooling capacity

    DOE Patents [OSTI]

    Weng, Kuo-Lianq (Taichung, TW); Weng, Kuo-Liang (Taichung, TW)

    1998-01-01

    The present air conditioning system with ice storing and cooling capacity can generate and store ice in its pipe assembly or in an ice storage tank particularly equipped for the system, depending on the type of the air conditioning system. The system is characterized in particular in that ice can be produced and stored in the air conditioning system whereby the time of supplying cooled air can be effectively extended with the merit that the operation cycle of the on and off of the compressor can be prolonged, extending the operation lifespan of the compressor in one aspect. In another aspect, ice production and storage in great amount can be performed in an off-peak period of the electrical power consumption and the stored ice can be utilized in the peak period of the power consumption so as to provide supplemental cooling capacity for the compressor of the air conditioning system whereby the shift of peak and off-peak power consumption can be effected with ease. The present air conditioning system can lower the installation expense for an ice-storing air conditioning system and can also be applied to an old conventional air conditioning system.

  18. Expansion fractionation capacity of the LPG-ULE plant

    SciTech Connect (OSTI)

    Morin, L.M.C.

    1999-07-01

    The Western Division of PDVSA has among other facilities a NGL Fractionation Complex located onshore in Ul'e. The complex consists of three plants, the first and second older plants, LPG-1 and LPG-2, which fractionate the NGL to produce propane, a butane mix and natural gasoline. The third plant, LPG-3, fractionates the butane mix from the LPG-1 and 2 plants to produce iso and normal butane. Several optimization projects already in progress will increase the NGL production to 12,200 b/d. For this reason it was decided to conduct a study of the existing fractionation facilities and utilities systems to determine their capacities. This evaluation revealed that some of the fractionation towers would have some limitations in the processing of the expected additional production. The study recommended an option to increase the capacity of the fractionation towers by lowering their operating pressure, in order to take advantage of relative volatility increase between the key components, which allows easier separation, as well as reducing the heat duty required. The completed study also determined that this option is more economically convenient than the replacement of the existing fractionation towers.

  19. Hyperdense coding and superadditivity of classical capacities in hypersphere theories

    E-Print Network [OSTI]

    Serge Massar; Stefano Pironio; Damián Pitalúa-García

    2015-04-20

    In quantum superdense coding, two parties previously sharing entanglement can communicate a two bit message by sending a single qubit. We study this feature in the broader framework of general probabilistic theories. We consider a particular class of theories in which the local state space of the communicating parties corresponds to Euclidian hyperballs of dimension n (the case n = 3 corresponds to the Bloch ball of quantum theory). We show that a single n-ball can encode at most one bit of information, independently of n. We introduce dense coding protocols in which log_2 (n+1) bits are communicated if entanglement is previously shared by the communicating parties. For n > 3, these protocols are more powerful than the quantum one, because more than two bits are communicated by transmission of a system that locally encodes at most one bit. We call this phenomenon hyperdense coding. Our hyperdense coding protocols imply superadditive classical capacities: two entangled systems can encode log_2 (n+1) > 2 bits, even though each system individually encodes at most one bit. In our examples, hyperdense coding and superadditivity of classical capacities come at the expense of violating tomographic locality or dynamical continuous reversibility.

  20. 2312 IEEE JOURNAL OF SOLID-STATE CIRCUITS, VOL. 46, NO. 10, OCTOBER 2011 A Miniature 2 mW 4 bit 1.2 GS/s Delay-Line-Based

    E-Print Network [OSTI]

    Afshari, Ehsan

    and multiband wire- less receivers are two examples of such applications, where be- side energy efficiency, area mechanism of the delay-line, this structure is more power efficient in the presence of noise and mismatch consumes 2 mW of power from a 1.2 V supply resulting in 196 fJ/conversion step without using any

  1. Dual capacity compressor with reversible motor and controls arrangement therefor

    DOE Patents [OSTI]

    Sisk, Francis J. (Washington Township, Fayette County, PA)

    1980-12-02

    A hermetic reciprocating compressor such as may be used in heat pump applications is provided for dual capacity operation by providing the crankpin of the crankshaft with an eccentric ring rotatably mounted thereon, and with the end of the connecting rod opposite the piston encompassing the outer circumference of the eccentric ring, with means limiting the rotation of the eccentric ring upon the crankpin between one end point and an opposite angularly displaced end point to provide different values of eccentricity depending upon which end point the eccentric ring is rotated to upon the crankpin, and a reversible motor in the hermetic shell of the compressor for rotating the crankshaft, the motor operating in one direction effecting the angular displacement of the eccentric ring relative to the crankpin to the one end point, and in the opposite direction effecting the angular displacement of the eccentric ring relative to the crankpin to the opposite end point, this arrangement automatically giving different stroke lengths depending upon the direction of motor rotation. The mechanical structure of the arrangement may take various forms including at least one in which any impact of reversal is reduced by utilizing lubricant passages and chambers at the interface area of the crankpin and eccentric ring to provide a dashpot effect. In the main intended application of the arrangement according to the invention, that is, in a refrigerating or air conditioning system, it is desirable to insure a delay during reversal of the direction of compressor operation. A control arrangement is provided in which the control system controls the direction of motor operation in accordance with temperature conditions, the system including control means for effecting operation in a low capacity direction or alternatively in a high capacity direction in response to one set, and another set, respectively, of temperature conditions and with timer means delaying a restart of the compressor motor for at least a predetermined time in response to a condition of the control means operative to initiate a change in the operating direction of the compressor when it restarts.

  2. High capacity adsorption media and method of producing

    DOE Patents [OSTI]

    Tranter, Troy J. (Idaho Falls, ID); Herbst, R. Scott (Idaho Falls, ID); Mann, Nicholas R. (Blackfoot, ID); Todd, Terry A. (Aberdeen, ID)

    2008-05-06

    A method of producing an adsorption medium to remove at least one constituent from a feed stream. The method comprises dissolving at least one metal compound in a solvent to form a metal solution, dissolving polyacrylonitrile into the metal solution to form a PAN-metal solution, and depositing the PAN-metal solution into a quenching bath to produce the adsorption medium. The at least one constituent, such as arsenic, selenium, or antimony, is removed from the feed stream by passing the feed stream through the adsorption medium. An adsorption medium having an increased metal loading and increased capacity for arresting the at least one constituent to be removed is also disclosed. The adsorption medium includes a polyacrylonitrile matrix and at least one metal hydroxide incorporated into the polyacrylonitrile matrix.

  3. High capacity adsorption media and method of producing

    DOE Patents [OSTI]

    Tranter, Troy J. (Idaho Falls, ID); Mann, Nicholas R. (Blackfoot, ID); Todd, Terry A. (Aberdeen, ID); Herbst, Ronald S. (Idaho Falls, ID)

    2010-10-05

    A method of producing an adsorption medium to remove at least one constituent from a feed stream. The method comprises dissolving and/or suspending at least one metal compound in a solvent to form a metal solution, dissolving polyacrylonitrile into the metal solution to form a PAN-metal solution, and depositing the PAN-metal solution into a quenching bath to produce the adsorption medium. The at least one constituent, such as arsenic, selenium, or antimony, is removed from the feed stream by passing the feed stream through the adsorption medium. An adsorption medium having an increased metal loading and increased capacity for arresting the at least one constituent to be removed is also disclosed. The adsorption medium includes a polyacrylonitrile matrix and at least one metal hydroxide incorporated into the polyacrylonitrile matrix.

  4. EVALUATION OF REQUIREMENTS FOR THE DWPF HIGHER CAPACITY CANISTER

    SciTech Connect (OSTI)

    Miller, D.; Estochen, E.; Jordan, J.; Kesterson, M.; Mckeel, C.

    2014-08-05

    The Defense Waste Processing Facility (DWPF) is considering the option to increase canister glass capacity by reducing the wall thickness of the current production canister. This design has been designated as the DWPF Higher Capacity Canister (HCC). A significant decrease in the number of canisters processed during the life of the facility would be achieved if the HCC were implemented leading to a reduced overall reduction in life cycle costs. Prior to implementation of the change, Savannah River National Laboratory (SRNL) was requested to conduct an evaluation of the potential impacts. The specific areas of interest included loading and deformation of the canister during the filling process. Additionally, the effect of the reduced wall thickness on corrosion and material compatibility needed to be addressed. Finally the integrity of the canister during decontamination and other handling steps needed to be determined. The initial request regarding canister fabrication was later addressed in an alternate study. A preliminary review of canister requirements and previous testing was conducted prior to determining the testing approach. Thermal and stress models were developed to predict the forces on the canister during the pouring and cooling process. The thermal model shows the HCC increasing and decreasing in temperature at a slightly faster rate than the original. The HCC is shown to have a 3°F ?T between the internal and outer surfaces versus a 5°F ?T for the original design. The stress model indicates strain values ranging from 1.9% to 2.9% for the standard canister and 2.5% to 3.1% for the HCC. These values are dependent on the glass level relative to the thickness transition between the top head and the canister wall. This information, along with field readings, was used to set up environmental test conditions for corrosion studies. Small 304-L canisters were filled with glass and subjected to accelerated environmental testing for 3 months. No evidence of stress corrosion cracking was indicated on either the canisters or U-bend coupons. Calculations and finite element modeling were used to determine forces over a range of handling conditions along with possible forces during decontamination. While expected reductions in some physical characteristics were found in the HCC, none were found to be significant when compared to the required values necessary to perform its intended function. Based on this study and a review of successful testing of thinner canisters at West Valley Demonstration Project (WVDP), the mechanical properties obtained with the thinner wall do not significantly undermine the ability of the canister to perform its intended function.

  5. Water Constraints in an Electric Sector Capacity Expansion Model

    SciTech Connect (OSTI)

    Macknick, Jordan; Cohen, Stuart; Newmark, Robin; Martinez, Andrew; Sullivan, Patrick; Tidwell, Vince

    2015-07-17

    This analysis provides a description of the first U.S. national electricity capacity expansion model to incorporate water resource availability and costs as a constraint for the future development of the electricity sector. The Regional Energy Deployment System (ReEDS) model was modified to incorporate water resource availability constraints and costs in each of its 134 Balancing Area (BA) regions along with differences in costs and efficiencies of cooling systems. Water resource availability and cost data are from recently completed research at Sandia National Laboratories (Tidwell et al. 2013b). Scenarios analyzed include a business-as-usual 3 This report is available at no cost from the National Renewable Energy Laboratory (NREL) at www.nrel.gov/publications. scenario without water constraints as well as four scenarios that include water constraints and allow for different cooling systems and types of water resources to be utilized. This analysis provides insight into where water resource constraints could affect the choice, configuration, or location of new electricity technologies.

  6. Wireless networks in non-ergodic multipath fading : capacity and relaying performance analysis

    E-Print Network [OSTI]

    Nebat, Yoav

    2007-01-01

    3 The Capacity of Wireless Networks in Non-Ergodic Multipathdiversity in wireless networks: Ef?cient protocols anddiversity in wireless networks,” IEEE Trans. Inf. Theory,

  7. Grid Integration and the Carrying Capacity of the U.S. Grid to...

    Broader source: Energy.gov (indexed) [DOE]

    identifies emerging practices in power system planning and operation that can facilitate grid integration, and proposes a unifying concept-economic carrying capacity-that can...

  8. Habitat Use and Energetic Carrying Capacity of American Black Ducks Wintering in Western Tennessee

    E-Print Network [OSTI]

    Gray, Matthew

    ) More info on Habitat Use Manage for more energe)cally important foods, and other waterfowl, and es)mate energe)c carrying capacity, in treated

  9. The Third Wave: Innovation and Strategic Military Capacity in the Future

    E-Print Network [OSTI]

    COWHEY, Peter

    2013-01-01

    APRIL 2013 The Third Wave: Innovation and Strategic Militaryassumes that the balance of innovation capacity matters forThe analysis treats innovation as the successful

  10. Estimate of Maximum Underground Working Gas Storage Capacity in the United States: 2007 Update

    Reports and Publications (EIA)

    2007-01-01

    This report provides an update to an estimate for U.S. aggregate natural gas storage capacity that was released in 2006.

  11. GE to DOE General Counsel; Re:Request for Comment on Large Capacity...

    Broader source: Energy.gov (indexed) [DOE]

    to amend the clothes washer test procedure to reflect efficiency standards of large-capacity residential clothes washer machines. GE also urges the DOE to adopt recommended...

  12. Capacity analysis, cycle time optimization, and supply chain strategy in multi-product biopharmaceutical manufacturing operations

    E-Print Network [OSTI]

    Fetcho-Phillips, Kacey L. (Kacey Lynn)

    2011-01-01

    Application of system optimization theory, supply chain principles, and capacity modeling are increasingly valuable tools for use in pharmaceutical manufacturing facilities. The dynamics of the pharmaceutical industry - ...

  13. Modeling the Capacity and Emissions Impacts of Reduced Electricity Demand. Part 1. Methodology and Preliminary Results.

    E-Print Network [OSTI]

    Coughlin, Katie

    2013-01-01

    ngcc nuclear coal ngcc nuclear other peaking renewable otherpeaking renewable Terawatt- hours Terawatt-hoursnuclear other peaking renewable Marginal Capacity Starting

  14. Exploring Opportunities for Energy Efficiency as a Revenue Stream in the Forward Capacity Markets

    Office of Energy Efficiency and Renewable Energy (EERE)

    Provides information for energy efficiency programs on the opportunities and challenges associated with participating in forward capacity markets and reliability pricing models as potential revenue streams.

  15. 1993 Pacific Northwest Loads and Resources Study, Technical Appendix: Volume 2, Book 2, Capacity.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    1993-12-01

    Monthly totals of utility loads and capacities extrapolated as far as 2009 with a probability estimate of enough water resources for hydro power.

  16. Waste treatment capacity of raft hydroponic lettuce production in an integrated fish culture system and the contribution of lettuce to treatment capacity 

    E-Print Network [OSTI]

    Gloger, Kelly C

    1995-01-01

    Two experiments were conducted to determine: 1.) the waste treatment capacity of raft hydroponic lettuce production in an integrated fish culture system and 2.) the contribution of lettuce plants, Lactuca saliva, cv. Paris ...

  17. 7-29 A coal-burning power plant produces 300 MW of power. The amount of coal consumed during a one-day period and the rate of air flowing through the furnace are to be determined.

    E-Print Network [OSTI]

    Bahrami, Majid

    7-11 7-29 A coal-burning power plant produces 300 MW of power. The amount of coal consumed during The power plant operates steadily. 2 The kinetic and potential energy changes are zero. Properties The heating value of the coal is given to be 28,000 kJ/kg. Analysis (a) The rate and the amount of heat inputs

  18. Natural gas productive capacity for the lower 48 States, 1980 through 1995

    SciTech Connect (OSTI)

    Not Available

    1994-07-14

    The purpose of this report is to analyze monthly natural gas wellhead productive capacity in the lower 48 States from 1980 through 1992 and project this capacity from 1993 through 1995. For decades, natural gas supplies and productive capacity have been adequate to meet demand. In the 1970`s the capacity surplus was small because of market structure (split between interstate and intrastate), increasing demand, and insufficient drilling. In the early 1980`s, lower demand, together with increased drilling, led to a large surplus capacity as new productive capacity came on line. After 1986, this large surplus began to decline as demand for gas increased, gas prices fell, and gas well completions dropped sharply. In late December 1989, the decline in this surplus, accompanied by exceptionally high demand and temporary weather-related production losses, led to concerns about the adequacy of monthly productive capacity for natural gas. These concerns should have been moderated by the gas system`s performance during the unusually severe winter weather in March 1993 and January 1994. The declining trend in wellhead productive capacity is expected to be reversed in 1994 if natural gas prices and drilling meet or exceed the base case assumption. This study indicates that in the low, base, and high drilling cases, monthly productive capacity should be able to meet normal production demands through 1995 in the lower 48 States (Figure ES1). Exceptionally high peak-day or peak-week production demand might not be met because of physical limitations such as pipeline capacity. Beyond 1995, as the capacity of currently producing wells declines, a sufficient number of wells and/or imports must be added each year in order to ensure an adequate gas supply.

  19. Complex Hydride Compounds with Enhanced Hydrogen Storage Capacity

    SciTech Connect (OSTI)

    Mosher, Daniel A.; Opalka, Susanne M.; Tang, Xia; Laube, Bruce L.; Brown, Ronald J.; Vanderspurt, Thomas H.; Arsenault, Sarah; Wu, Robert; Strickler, Jamie; Anton, Donald L.; Zidan, Ragaiy; Berseth, Polly

    2008-02-18

    The United Technologies Research Center (UTRC), in collaboration with major partners Albemarle Corporation (Albemarle) and the Savannah River National Laboratory (SRNL), conducted research to discover new hydride materials for the storage of hydrogen having on-board reversibility and a target gravimetric capacity of ? 7.5 weight percent (wt %). When integrated into a system with a reasonable efficiency of 60% (mass of hydride / total mass), this target material would produce a system gravimetric capacity of ? 4.5 wt %, consistent with the DOE 2007 target. The approach established for the project combined first principles modeling (FPM - UTRC) with multiple synthesis methods: Solid State Processing (SSP - UTRC), Solution Based Processing (SBP - Albemarle) and Molten State Processing (MSP - SRNL). In the search for novel compounds, each of these methods has advantages and disadvantages; by combining them, the potential for success was increased. During the project, UTRC refined its FPM framework which includes ground state (0 Kelvin) structural determinations, elevated temperature thermodynamic predictions and thermodynamic / phase diagram calculations. This modeling was used both to precede synthesis in a virtual search for new compounds and after initial synthesis to examine reaction details and options for modifications including co-reactant additions. The SSP synthesis method involved high energy ball milling which was simple, efficient for small batches and has proven effective for other storage material compositions. The SBP method produced very homogeneous chemical reactions, some of which cannot be performed via solid state routes, and would be the preferred approach for large scale production. The MSP technique is similar to the SSP method, but involves higher temperature and hydrogen pressure conditions to achieve greater species mobility. During the initial phases of the project, the focus was on higher order alanate complexes in the phase space between alkaline metal hydrides (AmH), Alkaline earth metal hydrides (AeH2), alane (AlH3), transition metal (Tm) hydrides (TmHz, where z=1-3) and molecular hydrogen (H2). The effort started first with variations of known alanates and subsequently extended the search to unknown compounds. In this stage, the FPM techniques were developed and validated on known alanate materials such as NaAlH4 and Na2LiAlH6. The coupled predictive methodologies were used to survey over 200 proposed phases in six quaternary spaces, formed from various combinations of Na, Li Mg and/or Ti with Al and H. A wide range of alanate compounds was examined using SSP having additions of Ti, Cr, Co, Ni and Fe. A number of compositions and reaction paths were identified having H weight fractions up to 5.6 wt %, but none meeting the 7.5 wt%H reversible goal. Similarly, MSP of alanates produced a number of interesting compounds and general conclusions regarding reaction behavior of mixtures during processing, but no alanate based candidates meeting the 7.5 wt% goal. A novel alanate, LiMg(AlH4)3, was synthesized using SBP that demonstrated a 7.0 wt% capacity with a desorption temperature of 150°C. The deuteride form was synthesized and characterized by the Institute for Energy (IFE) in Norway to determine its crystalline structure for related FPM studies. However, the reaction exhibited exothermicity and therefore was not reversible under acceptable hydrogen gas pressures for on-board recharging. After the extensive studies of alanates, the material class of emphasis was shifted to borohydrides. Through SBP, several ligand-stabilized Mg(BH4)2 complexes were synthesized. The Mg(BH4)2*2NH3 complex was found to change behavior with slightly different synthesis conditions and/or aging. One of the two mechanisms was an amine-borane (NH3BH3) like dissociation reaction which released up to 16 wt %H and more conservatively 9 wt%H when not including H2 released from the NH3. From FPM, the stability of the Mg(BH4)2*2NH3 compound was found to increase with the inclusion of NH3 groups in the inner-Mg coordination

  20. Transport Capacity of Wireless Networks: Benefits from Multi-Access Computation Coding

    E-Print Network [OSTI]

    Boucherie, Richard J.

    Transport Capacity of Wireless Networks: Benefits from Multi-Access Computation Coding Jasper on the transport capacity of wireless networks of different physical layer coding mechanisms. We compare the performance of traditional channel coding techniques, turning the wireless network in reliable point

  1. Capacity of a 3-D multi-layer optical data storage system , Edwin P. Walkera

    E-Print Network [OSTI]

    Esener, Sadik C.

    Capacity of a 3-D multi-layer optical data storage system Yi Zhanga* , Edwin P. Walkera , Wenyi) Emcore Fiber Optics Components, 1600 Eubank Blvd. SE, Albuquerque, NM 87123 ABSTRACT Storage capacity of a 3-D multi-layer optical data storage system is analyzed. Theoretical analysis of recorded bit size

  2. Physics 1114: Unit 7 Homework Use the table in your text for specific heat capacity values.

    E-Print Network [OSTI]

    Mansell, Edward "Ted"

    Physics 1114: Unit 7 Homework Use the table in your text for specific heat capacity values. Problem at 20 C? [Specific heat capacity of air = 703 J/(kg C ) at constant volume.] 7. What is the specific C? Specific Heat of Silver = 236 J/(kg C ) Melting point = 961 C Heat of Fusion = 8.7990 × 104 J

  3. Parameter Estimation and Capacity Fade Analysis of Lithium-Ion Batteries Using Reformulated Models

    E-Print Network [OSTI]

    Parameter Estimation and Capacity Fade Analysis of Lithium-Ion Batteries Using Reformulated Models and characterize capacity fade in lithium-ion batteries. As a comple- ment to approaches to mathematically model been made in developing lithium-ion battery models that incor- porate transport phenomena

  4. Stress generation during lithiation of high-capacity electrode particles in lithium ion batteries

    E-Print Network [OSTI]

    Zhu, Ting

    Stress generation during lithiation of high-capacity electrode particles in lithium ion batteries S in controlling stress generation in high-capacity electrodes for lithium ion batteries. Ó 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved. Keywords: Lithium ion battery; Lithiation

  5. Large Plastic Deformation in High-Capacity Lithium-Ion Batteries Caused by Charge and Discharge

    E-Print Network [OSTI]

    Suo, Zhigang

    Large Plastic Deformation in High-Capacity Lithium-Ion Batteries Caused by Charge and Discharge, Massachusetts 02138 Evidence has accumulated recently that a high-capacity elec- trode of a lithium-ion battery in the particle is high, possibly leading to fracture and cavitation. I. Introduction LITHIUM-ION batteries

  6. The Economic Implications of Adding Wind Capacity to a Bulk Power Transmission Network

    E-Print Network [OSTI]

    The Economic Implications of Adding Wind Capacity to a Bulk Power Transmission Network by Tim Mount. * Corresponding author, tdm2@cornell.edu. #12;2 The Economic Implications of Adding Wind Capacity to a Bulk Power limitations of solving large AC Optimal Power Flows (OPF) for real networks, system operators typically use

  7. ON MIMO CHANNEL CAPACITY, SPATIAL SAMPLING AND THE LAWS OF ELECTROMAGNETISM

    E-Print Network [OSTI]

    Loyka, Sergey

    ON MIMO CHANNEL CAPACITY, SPATIAL SAMPLING AND THE LAWS OF ELECTROMAGNETISM Sergey Loyka School by the laws of electromagnetism on achievable MIMO channel capacity in its general form. Our approach is a two expansion of a generic electromagnetic wave combined with Nyquist sampling theorem in the spatial domain, we

  8. Feedback Can Increase the CapacityCost Function of Discrete Channels with Memory y

    E-Print Network [OSTI]

    Alajaji, Fady

    bound to the capacity­cost func­ tion with feedback (CFB (fi)). The lower bound to CFB (fi) is then shown numerically to exceed the upper bound to CNFB (fi). An upper bound to CFB (fi) is also obtained and feedback capacity­cost functions -- denoted by CNFB (fi) and CFB (fi) respectively -- in order to deter

  9. System capacity of FTDMA cellular systems G. Caire 1 , R. Knopp 2 and P. Humblet 2

    E-Print Network [OSTI]

    Humblet, Pierre A.

    maximum outage probability. Outage is defined as the event that the mutual information of the interference on a typical urban mobile environment. Keywords --- Cellular system capacity, block­fading channels, outage are obtained as special cases. System capacity is constrained by the maximum allowed outage probability. We

  10. IEEE COMMUNICATIONS LETTERS, VOL. 17, NO. 1, JANUARY 2013 127 Capacity of Zero-Outage Scheme

    E-Print Network [OSTI]

    Candan, Cagatay

    IEEE COMMUNICATIONS LETTERS, VOL. 17, NO. 1, JANUARY 2013 127 Capacity of Zero-Outage Scheme Under Imprecise Channel State Information C¸ a~gatay Candan Abstract--The capacity of zero-outage scheme-to-noise-ratio fluctuates and the scheme suffers from com- munication outages. Exact analytical expressions characterizing

  11. Transmission Capacity of Decode-and-Forward Cooperation in Overlaid Wireless Networks

    E-Print Network [OSTI]

    Leung, Kin K.

    Transmission Capacity of Decode-and-Forward Cooperation in Overlaid Wireless Networks Zhengguo.ac.uk Abstract--In this paper, we employ a stochastic geometry model to analyze the transmission capacity the channel, whereas the SR users use only direct transmission. Because of the fact of coexistence

  12. Achievable Transmission Capacity of Cognitive Mesh Networks With Different Media Access

    E-Print Network [OSTI]

    Cheng, Xiuzhen "Susan"

    Achievable Transmission Capacity of Cognitive Mesh Networks With Different Media Access Control Tao, Beijing Jiaotong University, China 2Computer Science, The George Washington University, DC, USA E broadband access. In this paper we investigate the achievable transmission capacity of a wireless backhaul

  13. QUANTIFYING CROSS-WEAVE IMPACT ON CAPACITY REDUCTION FOR FREEWAY FACILITIES WITH MANAGED LANES

    E-Print Network [OSTI]

    Washington at Seattle, University of

    raises concerns towards environmental impact and sustainable development of transportation5 systems. One With the increasing concerns towards environmental impacts and sustainability of roadway2 capacity expansionDRAFT QUANTIFYING CROSS-WEAVE IMPACT ON CAPACITY REDUCTION FOR FREEWAY FACILITIES WITH MANAGED

  14. A High Capacity Hybrid Fiberoptic/Wireless Communication System: An Overview W. D. Jemison1

    E-Print Network [OSTI]

    Herczfeld, Peter

    A High Capacity Hybrid Fiberoptic/Wireless Communication System: An Overview by W. D. Jemison1 , P This paper describes the development of a hybrid fiberoptic/wireless communications system. The system picocell. The system can support high-capacity (Gb/s) secure mobile communications for both military

  15. TRANSBOUNDARY RIVER FLOODS AND INSTITUTIONAL CAPACITY1 Marloes H.N. Bakker2

    E-Print Network [OSTI]

    Wolf, Aaron

    TRANSBOUNDARY RIVER FLOODS AND INSTITUTIONAL CAPACITY1 Marloes H.N. Bakker2 ABSTRACT: While transboundary flood events have become more frequent on a global scale the past two dec- ades, they appear to identify the IRBs with adequate institutional capacity for management of transboundary floods. It also

  16. Capacity and Energy Cost of Information in Biological and Silicon Photoreceptors

    E-Print Network [OSTI]

    Maryland at College Park, University of

    Capacity and Energy Cost of Information in Biological and Silicon Photoreceptors PAMELA ABSHIRE of infor- mation capacity (in bits per second) versus energy cost of infor- mation (in joules per bit such as size, reliability, and energy re- quirements for natural and engineered sensory microsystems. I

  17. 1994 lubricating oil and wax capacities of U. S. and Canadian refineries

    SciTech Connect (OSTI)

    Not Available

    1994-01-01

    The paper consists of several tables which list the names of US and Canadian refineries, their location, and their capacity for production of lubricating oil and waxes categorized by finishing operations and primary processing. A separate table lists US and Canadian re-refiners and their capacity for refining waste lubricating oils.

  18. Approximate Dynamic Programming for Dynamic Capacity Allocation with Multiple Priority Levels

    E-Print Network [OSTI]

    Topaloglu, Huseyin

    Approximate Dynamic Programming for Dynamic Capacity Allocation with Multiple Priority Levels In this paper, we consider a quite general dynamic capacity allocation problem. There is a fixed amount of daily to construct separable approximations to the value functions. We use the value function approximations for two

  19. Proceedings of the 2009 Industrial Engineering Research Conference Simulation-based optimization for determining AGV capacity

    E-Print Network [OSTI]

    Gosavi, Abhijit

    for determining AGV capacity in a manufacturing system Abhijit Gosavi and Scott E. Grasman Email: gosavia Missouri University of Science and Technology, Rolla, MO 65409, USA Abstract We consider a manufacturing from the standpoint of making a system lean. Optimization of the AGV's capacity can be performed

  20. Evolution-cast: Temporal Evolution in Wireless Social Networks and Its Impact on Capacity

    E-Print Network [OSTI]

    Wang, Xinbing

    1 Evolution-cast: Temporal Evolution in Wireless Social Networks and Its Impact on Capacity Luoyi, the corresponding capacity is significantly impacted by both social relations and network evolution. In particular with each other through social relations but employ transmission via wireless communications. The network

  1. Stress evolution and capacity fade in constrained lithium-ion pouch cells

    E-Print Network [OSTI]

    Arnold, Craig B.

    Stress evolution and capacity fade in constrained lithium-ion pouch cells John Cannarella, Craig B 28 June 2013 Accepted 30 June 2013 Available online 13 July 2013 Keywords: Lithium-ion battery stress on lithium-ion battery life are investigated by monitoring the stack pressure and capacity

  2. Carborane-Based Metal-Organic Framework with High Methane and Hydrogen Storage Capacities

    E-Print Network [OSTI]

    Carborane-Based Metal-Organic Framework with High Methane and Hydrogen Storage Capacities Robert DSTP/v. The volumetric hydrogen storage capacity at 55 bar and 77 K is 49 g/L. These properties are comparable to those of current record holders in the area of methane and hydrogen storage. This initial example lays

  3. Capacity-Optimal Training for Space-Time Modulation over a Time-Varying Channel

    E-Print Network [OSTI]

    Swindlehurst, A. Lee

    Capacity-Optimal Training for Space-Time Modulation over a Time-Varying Channel Christian B. Peel-autocorrelation function for time-varying MIMO channels, we find a lower bound on capacity for trained modulation, and find for differential unitary space-time modulation is discussed and compared with that for trained modulation. We

  4. Capacity Value of PV and Wind Generation in the NV Energy System

    SciTech Connect (OSTI)

    Lu, Shuai; Diao, Ruisheng; Samaan, Nader A.; Etingov, Pavel V.

    2014-03-21

    Calculation of photovoltaic (PV) and wind power capacity values is important for estimating additional load that can be served by new PV or wind installations in the electrical power system. It also is the basis for assigning capacity credit payments in systems with markets. Because of variability in solar and wind resources, PV and wind generation contribute to power system resource adequacy differently from conventional generation. Many different approaches to calculating PV and wind generation capacity values have been used by utilities and transmission operators. Using the NV Energy system as a study case, this report applies peak-period capacity factor (PPCF) and effective load carrying capability (ELCC) methods to calculate capacity values for renewable energy sources. We show the connection between the PPCF and ELCC methods in the process of deriving a simplified approach that approximates the ELCC method. This simplified approach does not require generation fleet data and provides the theoretical basis for a quick check on capacity value results of PV and wind generation. The diminishing return of capacity benefit as renewable generation increases is conveniently explained using the simplified capacity value approach.

  5. Comparison of Capacity Value Methods for Photovoltaics in the Western United States

    SciTech Connect (OSTI)

    Madaeni, S. H.; Sioshansi, R.; Denholm, P.

    2012-07-01

    This report compares different capacity value estimation techniques applied to solar photovoltaics (PV). It compares more robust data and computationally intense reliability-based capacity valuation techniques to simpler approximation techniques at 14 different locations in the western United States. The capacity values at these locations are computed while holding the underlying power system characteristics fixed. This allows the effect of differences in solar availability patterns on the capacity value of PV to be directly ascertained, without differences in the power system confounding the results. Finally, it examines the effects of different PV configurations, including varying the orientation of a fixed-axis system and installing single- and double-axis tracking systems, on the capacity value. The capacity value estimations are done over an eight-year running from 1998 to 2005, and both long-term average capacity values and interannual capacity value differences (due to interannual differences in solar resource availability) are estimated. Overall, under the assumptions used in the analysis, we find that some approximation techniques can yield similar results to reliability-based methods such as effective load carrying capability.

  6. Effects of voluntary activity and genetic selection on aerobic capacity in house mice (Mus domesticus)

    E-Print Network [OSTI]

    Saltzman, Wendy

    Effects of voluntary activity and genetic selection on aerobic capacity in house mice (Mus of voluntary activity and genetic selection on aerobic capacity in house mice (Mus domesticus). J. Appl. Physiol. 84(1): 69­76, 1998.--An animal model was developed to study effects on components of exercise

  7. Reduction of heat capacity and phonon group velocity in silicon nanowires Christopher Marchbanks and Zhigang Wua)

    E-Print Network [OSTI]

    Wu, Zhigang

    Reduction of heat capacity and phonon group velocity in silicon nanowires Christopher Marchbanks distributions, resulting in an 15% to 23% reduction in heat capacity and an averaged decrease of 31% in acoustic thermoelectrics,10,11 photovoltaic cells,12,13 and light-emitting diodes.14 Nanowire structure and confinement

  8. Equilibrium Transitions from Non Renewable Energy to Renewable Energy under Capacity

    E-Print Network [OSTI]

    Equilibrium Transitions from Non Renewable Energy to Renewable Energy under Capacity Constraints 12 renewable and renewable energy sources with adjustment costs over the production capacity of renewable and a more expensive renewable energy, we show the following. With sufficiently abundant non renewable energy

  9. Heat capacity of silver paint A. LeR. Dawson and D. H. Ryan

    E-Print Network [OSTI]

    Ryan, Dominic

    Heat capacity of silver paint A. LeR. Dawson and D. H. Ryan Department of Physics, Center; accepted for publication 15 March 1996 The heat capacity [CP(T)] of a silver loaded paint has been measured,3 however, we have found a silver paint Flexible Silver No. 16 Ref. 4 to be better than Apiezon N for many

  10. Heat Capacity of Silver Paint A.LeR. Dawson and D.H. Ryan

    E-Print Network [OSTI]

    Ryan, Dominic

    Heat Capacity of Silver Paint A.LeR. Dawson and D.H. Ryan Department of Physics The heat capacity (C P (T )) of a silver loaded paint has been measured between 3 K and 30 K. It is shown is Apiezon N grease [2,3], however, we have found a silver paint (Flexible Silver #16 [4]) to be better than

  11. Journal of Environmental Health Features Tools Developed by CDC Capacity-Building Grantees

    E-Print Network [OSTI]

    Journal of Environmental Health Features Tools Developed by CDC Capacity-Building Grantees developed by the grantees are designed to be models and/or toolkits that can be used by other environmental­August 2007 Journal or Environmental Health featured articles written by capacity-building grantees: · Using

  12. Multi-Period Production Capacity Planning for Integrated Product and Production System Design*

    E-Print Network [OSTI]

    Saitou, Kazuhiro "Kazu"

    Multi-Period Production Capacity Planning for Integrated Product and Production System Design* Emre.ac.uk kazu@umich.edu .Abstract ­ This paper presents a simulation-based method to aid multi-period production capacity planning by quantifying the trade-off between product quality and production cost. The product

  13. MULTI-PERIOD CAPACITY PLANNING FOR INTEGRATED PRODUCT-PROCESS DESIGN

    E-Print Network [OSTI]

    Saitou, Kazuhiro "Kazu"

    MULTI-PERIOD CAPACITY PLANNING FOR INTEGRATED PRODUCT-PROCESS DESIGN Emre Kazancioglu Department-process design, robust design, capacity plan- ning, discrete event simulation, Monte Carlo simula- tion, multi increas- ing product quality by investing on higher quality machinery drives the price of the product up

  14. Optimal transition from coal to gas and renewable power under capacity constraints and adjustment costs

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Optimal transition from coal to gas and renewable power under capacity constraints and adjustment existing coal power plants to gas and renewable power under a carbon budget. It solves a model of polluting, exhaustible resources with capacity constraints and adjustment costs (to build coal, gas, and renewable power

  15. Self-adaptive Cloud Capacity Planning Yexi Jiang, Chang-shing Perng, Tao Li, Rong Chang

    E-Print Network [OSTI]

    Li, Tao

    Self-adaptive Cloud Capacity Planning Yexi Jiang, Chang-shing Perng, Tao Li, Rong Chang School}@us.ibm.com Abstract--The popularity of cloud service spurs the increas- ing demands of cloud resources to the cloud a new method for cloud capacity planning with the goal of fully utilizing the physical resources, as we

  16. Improving Power System Modeling. A Tool to Link Capacity Expansion and Production Cost Models

    SciTech Connect (OSTI)

    Diakov, Victor; Cole, Wesley; Sullivan, Patrick; Brinkman, Gregory; Margolis, Robert

    2015-11-01

    Capacity expansion models (CEM) provide a high-level long-term view at the prospects of the evolving power system. In simulating the possibilities of long-term capacity expansion, it is important to maintain the viability of power system operation in the short-term (daily, hourly and sub-hourly) scales. Production-cost models (PCM) simulate routine power system operation on these shorter time scales using detailed load, transmission and generation fleet data by minimizing production costs and following reliability requirements. When based on CEM 'predictions' about generating unit retirements and buildup, PCM provide more detailed simulation for the short-term system operation and, consequently, may confirm the validity of capacity expansion predictions. Further, production cost model simulations of a system that is based on capacity expansion model solution are 'evolutionary' sound: the generator mix is the result of logical sequence of unit retirement and buildup resulting from policy and incentives. The above has motivated us to bridge CEM with PCM by building a capacity expansion - to - production cost model Linking Tool (CEPCoLT). The Linking Tool is built to onset capacity expansion model prescriptions onto production cost model inputs. NREL's ReEDS and Energy Examplar's PLEXOS are the capacity expansion and the production cost models, respectively. Via the Linking Tool, PLEXOS provides details of operation for the regionally-defined ReEDS scenarios.

  17. Rocky Mountain Regional CO{sub 2} Storage Capacity and Significance

    SciTech Connect (OSTI)

    Laes, Denise; Eisinger, Chris; Esser, Richard; Morgan, Craig; Rauzi, Steve; Scholle, Dana; Matthews, Vince; McPherson, Brian

    2013-08-30

    The purpose of this study includes extensive characterization of the most promising geologic CO{sub 2} storage formations on the Colorado Plateau, including estimates of maximum possible storage capacity. The primary targets of characterization and capacity analysis include the Cretaceous Dakota Formation, the Jurassic Entrada Formation and the Permian Weber Formation and their equivalents in the Colorado Plateau region. The total CO{sub 2} capacity estimates for the deep saline formations of the Colorado Plateau region range between 9.8 metric GT and 143 metric GT, depending on assumed storage efficiency, formations included, and other factors.

  18. Transparent hydrogel with enhanced water retention capacity by introducing highly hydratable salt

    SciTech Connect (OSTI)

    Bai, Yuanyuan; Xiang, Feng; Wang, Hong E-mail: suo@seas.harvard.edu; Chen, Baohong; Zhou, Jinxiong; Suo, Zhigang E-mail: suo@seas.harvard.edu

    2014-10-13

    Polyacrylamide hydrogels containing salt as electrolyte have been used as highly stretchable transparent electrodes in flexible electronics, but those hydrogels are easy to dry out due to water evaporation. Targeted, we try to enhance water retention capacity of polyacrylamide hydrogel by introducing highly hydratable salts into the hydrogel. These hydrogels show enhanced water retention capacity in different level. Specially, polyacrylamide hydrogel containing high content of lithium chloride can retain over 70% of its initial water even in environment with relative humidity of only 10% RH. The excellent water retention capacities of these hydrogels will make more applications of hydrogels become possible.

  19. Multiple-part-type systems in high volume manufacturing : long-term capacity planning & time-based production control

    E-Print Network [OSTI]

    Hua, Xia, M. Eng. Massachusetts Institute of Technology

    2008-01-01

    This project examines a production station that faces fluctuating demand with seasonal pattern. The cumulative capacity exceeds the cumulative demand in a one year period; however, its weekly capacity is not able to meet ...

  20. Effect of spatial variability on the bearing capacity of cement-treated ground

    E-Print Network [OSTI]

    Kasama, Kiyonobu

    This paper presents a reliability assessment for the undrained bearing capacity of a surface strip foundation based on the results of a probabilistic study in which the shear strength and unit weight of cement-treated ...