Sample records for municipal water system

  1. Contaminant Transport in Municipal Water Systems

    E-Print Network [OSTI]

    Stockie, John

    Chapter 1 Contaminant Transport in Municipal Water Systems Presented at the 3rd PIMS Industrial the inverse problem. We begin in the following sections with an overview of the physics of ow in water forcing to raise the hydraulic head of the water in the network. The nodes are either junctions, tanks

  2. Challenges of Handling Storm Water Runoff Through Municipal Sewer Systems

    E-Print Network [OSTI]

    Illinois at Urbana-Champaign, University of

    cleaned and retained as a Best Management Practice (BMP). Receives only non-industrial storm water on storm water are leading municipalities to change permitting practices. As a result, facilitiesChallenges of Handling Storm Water Runoff Through Municipal Sewer Systems A South Carolina Case

  3. Modeling Integrated Decisions for a Municipal Water System with Recourse and Uncertainties

    E-Print Network [OSTI]

    Pasternack, Gregory B.

    for a municipal water system to cost-effectively accommodate a distribution of water shortages. Alternative robust in action costs, life spans, water volumes gained or saved, shortage levels, and shortage probabilities make water shortages pressing or impending realities for Amman, Jordan and many other urban water

  4. Detection of contamination of municipal water distribution systems

    DOE Patents [OSTI]

    Cooper, John F. (Oakland, CA)

    2012-01-17T23:59:59.000Z

    A system for the detection of contaminates of a fluid in a conduit. The conduit is part of a fluid distribution system. A chemical or biological sensor array is connected to the conduit. The sensor array produces an acoustic signal burst in the fluid upon detection of contaminates in the fluid. A supervisory control system connected to the fluid and operatively connected to the fluid distribution system signals the fluid distribution system upon detection of contaminates in the fluid.

  5. Marshall Municipal Utilities- Solar Thermal Water Heater Rebate Program

    Broader source: Energy.gov [DOE]

    Marshall Municipal Utilities (MMU) offers residential customers rebates for installing a ENERGY STAR Solar Thermal Water Heater. Rebates are based on the size of the system; MMU offers $20 per...

  6. Use of Treated Municipal Wastewater as Power Plant Cooling System Makeup Water: Tertiary Treatment versus Expanded Chemical Regimen for Recirculating Water Quality Management

    SciTech Connect (OSTI)

    David Dzombak; Radisav Vidic; Amy Landis

    2012-06-30T23:59:59.000Z

    Treated municipal wastewater is a common, widely available alternative source of cooling water for thermoelectric power plants across the U.S. However, the biodegradable organic matter, ammonia-nitrogen, carbonate and phosphates in the treated wastewater pose challenges with respect to enhanced biofouling, corrosion, and scaling, respectively. The overall objective of this study was to evaluate the benefits and life cycle costs of implementing tertiary treatment of secondary treated municipal wastewater prior to use in recirculating cooling systems. The study comprised bench- and pilot-scale experimental studies with three different tertiary treated municipal wastewaters, and life cycle costing and environmental analyses of various tertiary treatment schemes. Sustainability factors and metrics for reuse of treated wastewater in power plant cooling systems were also evaluated. The three tertiary treated wastewaters studied were: secondary treated municipal wastewater subjected to acid addition for pH control (MWW_pH); secondary treated municipal wastewater subjected to nitrification and sand filtration (MWW_NF); and secondary treated municipal wastewater subjected nitrification, sand filtration, and GAC adsorption (MWW_NFG). Tertiary treatment was determined to be essential to achieve appropriate corrosion, scaling, and biofouling control for use of secondary treated municipal wastewater in power plant cooling systems. The ability to control scaling, in particular, was found to be significantly enhanced with tertiary treated wastewater compared to secondary treated wastewater. MWW_pH treated water (adjustment to pH 7.8) was effective in reducing scale formation, but increased corrosion and the amount of biocide required to achieve appropriate biofouling control. Corrosion could be adequately controlled with tolytriazole addition (4-5 ppm TTA), however, which was the case for all of the tertiary treated waters. For MWW_NF treated water, the removal of ammonia by nitrification helped to reduce the corrosivity and biocide demand. Also, the lower pH and alkalinity resulting from nitrification reduced the scaling to an acceptable level, without the addition of anti-scalant chemicals. Additional GAC adsorption treatment, MWW_NFG, yielded no net benefit. Removal of organic matter resulted in pitting corrosion in copper and cupronickel alloys. Negligible improvement was observed in scaling control and biofouling control. For all of the tertiary treatments, biofouling control was achievable, and most effectively with pre-formed monochloramine (2-3 ppm) in comparison with NaOCl and ClO2. Life cycle cost (LCC) analyses were performed for the tertiary treatment systems studied experimentally and for several other treatment options. A public domain conceptual costing tool (LC3 model) was developed for this purpose. MWW_SF (lime softening and sand filtration) and MWW_NF were the most cost-effective treatment options among the tertiary treatment alternatives considered because of the higher effluent quality with moderate infrastructure costs and the relatively low doses of conditioning chemicals required. Life cycle inventory (LCI) analysis along with integration of external costs of emissions with direct costs was performed to evaluate relative emissions to the environment and external costs associated with construction and operation of tertiary treatment alternatives. Integrated LCI and LCC analysis indicated that three-tiered treatment alternatives such as MWW_NSF and MWW_NFG, with regular chemical addition for treatment and conditioning and/or regeneration, tend to increase the impact costs and in turn the overall costs of tertiary treatment. River water supply and MWW_F alternatives with a single step of tertiary treatment were associated with lower impact costs, but the contribution of impact costs to overall annual costs was higher than all other treatment alternatives. MWW_NF and MWW_SF alternatives exhibited moderate external impact costs with moderate infrastructure and chemical conditioner dosing, which makes them (especially

  7. Draft Transcript on Municipal PV Systems

    Broader source: Energy.gov [DOE]

    Webinar on navigating the legal, tax, and finance issues associated with the installation of Municipal PV Systems. The following agenda was developed based on Pat Boylston's experience assisting municipalities with their PV projects and the requests for information that the Solar America City technical team leads have received from many of the 25 Solar America Cities since the April 2008 meeting in Tucson.

  8. Columbia River System Operation Review : Final Environmental Impact Statement, Appendix F: Irrigation, Municipal and Industrial/Water Supply.

    SciTech Connect (OSTI)

    Columbia River System Operations Review (U.S.); United States. Bonneville Power Administration; United States. Army. Corps of Engineers. North Pacific Division; United States. Bureau of Reclamation. Pacific Northwest Region.

    1995-11-01T23:59:59.000Z

    Since the 1930`s, the Columbia River has been harnessed for the benefit of the Northwest and the nation. Federal agencies have built 30 major dams on the river and its tributaries. Dozens of non-Federal projects have been developed as well. The dams provide flood control, irrigation, navigation, hydro-electric power generation, recreation, fish and wildlife, and streamflows for wildlife, anadromous fish, resident fish, and water quality. This is Appendix F of the Environmental Impact Statement for the Columbia River System, focusing on irrigation issues and concerns arrising from the Irrigation and Mitigation of impacts (M&I) working Group of the SOR process. Major subheadings include the following: Scope and process of irrigation/M&I studies; Irrigation/M&I in the Columbia Basin Today including overview, irrigated acreage and water rights, Irrigation and M&I issues basin-wide and at specific locations; and the analysis of impacts and alternative for the Environmental Impact Statement.

  9. Feasibility of Municipal Water Mains as Heat Sink for Residential Air-Conditioning

    E-Print Network [OSTI]

    Vliet, G. C.

    1994-01-01T23:59:59.000Z

    It has been proposed that municipal water mains be used as the heat sink or the heat source for air-conditioning or heating, respectively. This paper addresses the extent of thermal contamination associated with the use of municipal water...

  10. Water-related environmental control requirements at municipal solid waste-to-energy conversion facilities

    SciTech Connect (OSTI)

    Young, J C; Johnson, L D

    1980-09-01T23:59:59.000Z

    Water use and waste water production, water pollution control technology requirements, and water-related limitations to their design and commercialization are identified at municipal solid waste-to-energy conversion systems. In Part I, a summary of conclusions and recommendations provides concise statements of findings relative to water management and waste water treatment of each of four municipal solid waste-to-energy conversion categories investigated. These include: mass burning, with direct production of steam for use as a supplemental energy source; mechanical processing to produce a refuse-derived fuel (RDF) for co-firing in gas, coal or oil-fired power plants; pyrolysis for production of a burnable oil or gas; and biological conversion of organic wastes to methane. Part II contains a brief description of each waste-to-energy facility visited during the subject survey showing points of water use and wastewater production. One or more facilities of each type were selected for sampling of waste waters and follow-up tests to determine requirements for water-related environmental controls. A comprehensive summary of the results are presented. (MCW)

  11. Energy optimization of water and wastewater management for municipal and industrial applications conference

    SciTech Connect (OSTI)

    Not Available

    1980-08-01T23:59:59.000Z

    These proceedings document the presentations given at the Energy Optimization of Water and Wastewater Management for Municipal and Industrial Applications Conference, sponsored by the Department of Energy (DOE). The conference was organized and coordinated by Argonne National Laboratory. The conference focused on energy use and conservation in water and wastewater. The General Session also reflects DOE's commitment to the support and development of waste and wastewater systems that are environmentally acceptable. The conference proceedings are divided into two volumes. Volume 1 contains the General Session and Sessions 1 to 5. Volume 2 covers Sessions 6 to 12. Separate abstracts are prepared for each item within the scope of the Energy Data Base.

  12. Energy optimization of water and wastewater management for municipal and industrial applications conference

    SciTech Connect (OSTI)

    Not Available

    1980-08-01T23:59:59.000Z

    These proceedings document the presentations given at the Energy Optimization of Water and Wastewater Management for Municipal and Industrial Applications, Conference, sponsored by the Department of Energy (DOE). The conference was organized and coordinated by Argonne National Laboratory. The conference focused on energy use on conservation in water and wastewater. The General Session also reflects DOE's commitment to the support and development of waste and wastewater systems that are environmentally acceptable. The conference proceedings are divided into two volumes. Volume 1 contains the General Session and Sessions 1 to 5. Volume 2 covers Sessions 6 to 12. Separate abstracts are prepared for each item within the scope of the Energy Data Base.

  13. Economies of size in municipal water treatment technologies: Texas lower Rio Grande Valley 

    E-Print Network [OSTI]

    Boyer, Christopher Neil

    2008-10-10T23:59:59.000Z

    , technological advancements have improved the economic viability of reverse-osmosis (RO) desalination of brackish-groundwater as a potable water source. Brackish-groundwater may be an alternative water source that provides municipalities an opportunity to hedge...

  14. Wind Energy Applications for Municipal Water Services: Opportunities, Situation Analyses, and Case Studies; Preprint

    SciTech Connect (OSTI)

    Flowers, L.; Miner-Nordstrom, L.

    2006-01-01T23:59:59.000Z

    As communities grow, greater demands are placed on water supplies, wastewater services, and the electricity needed to power the growing water services infrastructure. Water is also a critical resource for thermoelectric power plants. Future population growth in the United States is therefore expected to heighten competition for water resources. Many parts of the United States with increasing water stresses also have significant wind energy resources. Wind power is the fastest-growing electric generation source in the United States and is decreasing in cost to be competitive with thermoelectric generation. Wind energy can offer communities in water-stressed areas the option of economically meeting increasing energy needs without increasing demands on valuable water resources. Wind energy can also provide targeted energy production to serve critical local water-system needs. The research presented in this report describes a systematic assessment of the potential for wind power to support water utility operation, with the objective to identify promising technical applications and water utility case study opportunities. The first section describes the current situation that municipal providers face with respect to energy and water. The second section describes the progress that wind technologies have made in recent years to become a cost-effective electricity source. The third section describes the analysis employed to assess potential for wind power in support of water service providers, as well as two case studies. The report concludes with results and recommendations.

  15. Esthetically Designed Municipal PV System Maximizes Energy Production and Revenue Return

    Broader source: Energy.gov [DOE]

    In late 2008, the City of Sebastopol, CA installed a unique 42 kW grid-interactive photovoltaic (PV) system to provide electricity for pumps of the Sebastopol municipal water system. The resulting innovative Sun Dragon PV system, located in a public park, includes design elements that provide optimized electrical performance and revenue generation for the energy produced while also presenting an artistic and unique appearance to park visitors.

  16. Scenarios of Global Municipal Water-Use Demand Projections over the 21st Century

    SciTech Connect (OSTI)

    Hejazi, Mohamad I.; Edmonds, James A.; Chaturvedi, Vaibhav; Davies, Evan; Eom, Jiyong

    2013-03-06T23:59:59.000Z

    This paper establishes three future projections of global municipal water use to the end of the 21st century: A reference business-as usual (BAU) scenario, a High Technological Improvement (High Tech) scenario and a Low Technological Improvement (Low Tech) scenario. A global municipal water demand model is constructed using global water use statistics at the country-scale, calibrated to the base year of 2005, and simulated to the end of the 21st century. Since the constructed water demand model hinges on socioeconomic variables (population, income), water price, and end-use technology and efficiency improvement rates, projections of those input variables are adopted to characterize the uncertainty in future water demand estimates. The water demand model is linked to the Global Change Assessment Model (GCAM), a global change integrated assessment model. Under the reference scenario, the global total water withdrawal increases from 466 km3/year in 2005 to 941 km3/year in 2100,while withdrawals in the high and low tech scenarios are 321 km3/ year and 2000 km3/ year, respectively. This wide range (321-2000 km3/ year) indicates the level of uncertainty associated with such projections. The simulated global municipal demand projections are most sensitive to population and income projections, then to end-use technology and efficiency projections, and finally to water price. Thus, using water price alone as a policy measure to reduce municipal water use may substantiate the share of municipal water price of people’s annual incomes.

  17. ANNUAL REPORT General Permit for the Discharger of Storm Water from Small Municipal Separate

    E-Print Network [OSTI]

    California at Santa Cruz, University of

    . These activities and structural improvements are referred to as Best Management Practices (BMPs). BMPs9/14/11 1 ANNUAL REPORT General Permit for the Discharger of Storm Water from Small Municipal. Permittee (Agency Name): University of California Santa Cruz 2. Contact Person: _Courtney Trask, Storm Water

  18. ANNUAL REPORT General Permit for the Discharger of Storm Water from Small Municipal Separate

    E-Print Network [OSTI]

    California at Santa Cruz, University of

    . These activities and structural improvements are referred to as Best Management Practices (BMPs). BMPs9/14/10 1 ANNUAL REPORT General Permit for the Discharger of Storm Water from Small Municipal. Permittee (Agency Name): University of California Santa Cruz 2. Contact Person: _Courtney Trask, Storm Water

  19. ANNUAL REPORT General Permit for the Discharger of Storm Water from Small Municipal Separate

    E-Print Network [OSTI]

    California at Santa Cruz, University of

    , 2013 to June 30, 2014 (Year 5) The University of California at Santa Cruz's Storm Water Management improvements are referred to as Best Management Practices (BMPs). BMPs will be updated as appropriate1 ANNUAL REPORT General Permit for the Discharger of Storm Water from Small Municipal Separate

  20. Before the tap runs dry: Municipal water users urged to conserve to help declining supplies

    E-Print Network [OSTI]

    Wythe, Kathy

    2013-01-01T23:59:59.000Z

    2 txH2O Fall 2013 Story by Kathy Wythe Photo from Crestock.com. BEFORE THE TAP RUNS DRY Municipal water users urged to conserve to help declining supplies Fall 2013 txH2O 3 The future of water in Texas consists of ?what ifs.? What...? scenarios don?t have to happen. If there is anything positive about the state?s continuing drought, it is that it has motivated legislators, state agencies and local municipalities to take action. Many agree that something has to be done. And...

  1. Before the tap runs dry: Municipal water users urged to conserve to help declining supplies 

    E-Print Network [OSTI]

    Wythe, Kathy

    2013-01-01T23:59:59.000Z

    water user, a#14;er agricultural irrigation and other urban uses, such as in-home and municipal use,? Cabrera said. Finch said some Texas cities still use #31;#30; percent or more of their water for landscapes, a prime target for water conservation... and you are using the right amount of water and the right kind of plants.? According to Wagner, a number of strategies, tools and management practices can signi#19;cantly reduce water usage in urban landscape irrigation. ?Using water-conserving...

  2. Kinematic wave model for water movement in municipal solid waste

    E-Print Network [OSTI]

    Bendz, David; Singh, Vijay P.; Rosqvist, H??kan; Bengtsson, Lars

    convection-dispersion equation (CDE). Furthermore, the soil water diffusivity, defined by Klute [1952], and the forms of Department of Water Resources Engineering, Lund University, Lund, Sweden. 2Department of Civil and Environmental Engineering..., Louisiana State University, Baton Rouge. 3Division of Land and Water Resources, Royal Institute of Tech- nology, Stockholm, Sweden. Copyright 1998 by the American Geophysical Union. Paper number 98WR01109. 0043-1397/98/98 WR-01109509.00 hydraulic...

  3. LCA comparison of container systems in municipal solid waste management

    SciTech Connect (OSTI)

    Rives, Jesus, E-mail: Jesus.Rives@uab.ca [SosteniPrA (UAB-IRTA), Institute of Environmental Science and Technology (ICTA), Universitat Autonoma de Barcelona - UAB, 08193 Bellaterra, Barcelona (Spain); Rieradevall, Joan; Gabarrell, Xavier [SosteniPrA (UAB-IRTA), Institute of Environmental Science and Technology (ICTA), Universitat Autonoma de Barcelona - UAB, 08193 Bellaterra, Barcelona (Spain); Department of Chemical Engineering, Universitat Autonoma de Barcelona - UAB, 08193 Bellaterra, Barcelona (Spain)

    2010-06-15T23:59:59.000Z

    The planning and design of integrated municipal solid waste management (MSWM) systems requires accurate environmental impact evaluation of the systems and their components. This research assessed, quantified and compared the environmental impact of the first stage of the most used MSW container systems. The comparison was based on factors such as the volume of the containers, from small bins of 60-80 l to containers of 2400 l, and on the manufactured materials, steel and high-density polyethylene (HDPE). Also, some parameters such as frequency of collections, waste generation, filling percentage and waste container contents, were established to obtain comparable systems. The methodological framework of the analysis was the life cycle assessment (LCA), and the impact assessment method was based on CML 2 baseline 2000. Results indicated that, for the same volume, the collection systems that use HDPE waste containers had more of an impact than those using steel waste containers, in terms of abiotic depletion, global warming, ozone layer depletion, acidification, eutrophication, photochemical oxidation, human toxicity and terrestrial ecotoxicity. Besides, the collection systems using small HDPE bins (60 l or 80 l) had most impact while systems using big steel containers (2400 l) had less impact. Subsequent sensitivity analysis about the parameters established demonstrated that they could change the ultimate environmental impact of each waste container collection system, but that the comparative relationship between systems was similar.

  4. Municipal District Heating and Cooling Co-generation System Feasibility Research 

    E-Print Network [OSTI]

    Zhang, W.; Guan, W.; Pan, Y.; Ding, G.; Song, X.; Zhang, Y.; Li, Y.; Wei, H.; He, Y.

    2006-01-01T23:59:59.000Z

    In summer absorption refrigerating machines provide cold water using excess heat from municipal thermoelectric power plant through district heating pipelines, which reduces peak electric load from electricity networks in summer. The paper simulates...

  5. Municipal District Heating and Cooling Co-generation System Feasibility Research

    E-Print Network [OSTI]

    Zhang, W.; Guan, W.; Pan, Y.; Ding, G.; Song, X.; Zhang, Y.; Li, Y.; Wei, H.; He, Y.

    2006-01-01T23:59:59.000Z

    In summer absorption refrigerating machines provide cold water using excess heat from municipal thermoelectric power plant through district heating pipelines, which reduces peak electric load from electricity networks in summer. The paper simulates...

  6. North Branch Municipal Water and Light- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Southern Minnesota Municipal Power Agency ([http://www.smmpa.com SMMPA]) is a joint-action agency which generates and sells reliable electricity at wholesale to its eighteen non-profit, municipally...

  7. Stormwater and Urban Water Systems Modeling Conference. In: Models and Applications to Urban Water Systems, Vol. 12 (edited by W. James). CHI. Guelph, Ontario, pp. 257 294. 2004.

    E-Print Network [OSTI]

    Pitt, Robert E.

    Stormwater and Urban Water Systems Modeling Conference. In: Models and Applications to Urban Water AND EXAMINATION OF A MUNICIPAL SEPARATE STORM SEWER SYSTEM DATABASE Robert Pitt, Alex Maestre, Renee Morquecho of Water 104(b)3 grant in 2001 to collect and evaluate stormwater data from a representative number

  8. Reactor water cleanup system

    DOE Patents [OSTI]

    Gluntz, D.M.; Taft, W.E.

    1994-12-20T23:59:59.000Z

    A reactor water cleanup system includes a reactor pressure vessel containing a reactor core submerged in reactor water. First and second parallel cleanup trains are provided for extracting portions of the reactor water from the pressure vessel, cleaning the extracted water, and returning the cleaned water to the pressure vessel. Each of the cleanup trains includes a heat exchanger for cooling the reactor water, and a cleaner for cleaning the cooled reactor water. A return line is disposed between the cleaner and the pressure vessel for channeling the cleaned water thereto in a first mode of operation. A portion of the cooled water is bypassed around the cleaner during a second mode of operation and returned through the pressure vessel for shutdown cooling. 1 figure.

  9. Purge water management system

    DOE Patents [OSTI]

    Cardoso-Neto, Joao E. (North Augusta, SC); Williams, Daniel W. (Aiken, SC)

    1996-01-01T23:59:59.000Z

    A purge water management system for effectively eliminating the production of purge water when obtaining a groundwater sample from a monitoring well. In its preferred embodiment, the purge water management system comprises an expandable container, a transportation system, and a return system. The purge water management system is connected to a wellhead sampling configuration, typically permanently installed at the well site. A pump, positioned with the monitoring well, pumps groundwater through the transportation system into the expandable container, which expands in direct proportion with volume of groundwater introduced, usually three or four well volumes, yet prevents the groundwater from coming into contact with the oxygen in the air. After this quantity of groundwater has been removed from the well, a sample is taken from a sampling port, after which the groundwater in the expandable container can be returned to the monitoring well through the return system. The purge water management system prevents the purge water from coming in contact with the outside environment, especially oxygen, which might cause the constituents of the groundwater to oxidize. Therefore, by introducing the purge water back into the monitoring well, the necessity of dealing with the purge water as a hazardous waste under the Resource Conservation and Recovery Act is eliminated.

  10. Purge water management system

    DOE Patents [OSTI]

    Cardoso-Neto, J.E.; Williams, D.W.

    1995-01-01T23:59:59.000Z

    A purge water management system is described for effectively eliminating the production of purge water when obtaining a groundwater sample from a monitoring well. In its preferred embodiment, the purge water management system comprises an expandable container, a transportation system, and a return system. The purge water management system is connected to a wellhead sampling configuration, typically permanently installed at the well site. A pump, positioned with the monitoring well, pumps groundwater through the transportation system into the expandable container, which expands in direct proportion with volume of groundwater introduced, usually three or four well volumes, yet prevents the groundwater from coming into contact with the oxygen in the air. After this quantity of groundwater has been removed from the well, a sample is taken from a sampling port, after which the groundwater in the expandable container can be returned to the monitoring well through the return system. The purge water management system prevents the purge water from coming in contact with the outside environment, especially oxygen, which might cause the constituents of the groundwater to oxidize. Therefore, by introducing the purge water back into the monitoring well, the necessity of dealing with the purge water as a hazardous waste under the Resource Conservation and Recovery Act is eliminated.

  11. North Branch Municipal Water and Light- Commercial and Industrial Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Southern Minnesota Municipal Power Agency ([http://www.smmpa.com SMMPA]) is a joint-action agency which generates and sells reliable electricity at wholesale to its eighteen non-profit,...

  12. Cooling water distribution system

    DOE Patents [OSTI]

    Orr, Richard (Pittsburgh, PA)

    1994-01-01T23:59:59.000Z

    A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using an interconnected series of radial guide elements, a plurality of circumferential collector elements and collector boxes to collect and feed the cooling water into distribution channels extending along the curved surface of the steel containment vessel. The cooling water is uniformly distributed over the curved surface by a plurality of weirs in the distribution channels.

  13. Cooling Water System Optimization

    E-Print Network [OSTI]

    Aegerter, R.

    2005-01-01T23:59:59.000Z

    During summer months, many manufacturing plants have to cut back in rates because the cooling water system is not providing sufficient cooling to support higher production rates. There are many low/no-cost techniques available to improve tower...

  14. Economies of size in municipal water treatment technologies: Texas lower Rio Grande Valley

    E-Print Network [OSTI]

    Boyer, Christopher Neil

    2008-10-10T23:59:59.000Z

    .e., public), a 0.0% risk rate is applied for comparison purposes. Under the State of Texas Water Code chapter 67, a political subdivision may be contracted by the private entity to administrate the bonds, resulting in a virtually risk free bond (Texas... cost of $0.06 per kWh. life for the facility and distribution system, as well as an 8.0% discount rate. They concluded that economies of size do exist for the combined water treatment facility and distribution system, but individually, the treatment...

  15. Denton Municipal Electric- GreenSense Solar Rebate Program

    Broader source: Energy.gov [DOE]

    Denton Municipal Electric offers rebates to its electric customers for the installation of solar PV and solar water heating systems. The solar rebates are designed for residential and small...

  16. Waste collection systems for recyclables: An environmental and economic assessment for the municipality of Aarhus (Denmark)

    SciTech Connect (OSTI)

    Larsen, A.W., E-mail: awl@env.dtu.d [Department of Environmental Engineering, Technical University of Denmark, Miljoevej, Building 113, DK-2800 Kongens Lyngby (Denmark); Merrild, H.; Moller, J.; Christensen, T.H. [Department of Environmental Engineering, Technical University of Denmark, Miljoevej, Building 113, DK-2800 Kongens Lyngby (Denmark)

    2010-05-15T23:59:59.000Z

    Recycling of paper and glass from household waste is an integrated part of waste management in Denmark, however, increased recycling is a legislative target. The questions are: how much more can the recycling rate be increased through improvements of collection schemes when organisational and technical limitations are respected, and what will the environmental and economic consequences be? This was investigated in a case study of a municipal waste management system. Five scenarios with alternative collection systems for recyclables (paper, glass, metal and plastic packaging) were assessed by means of a life cycle assessment and an assessment of the municipality's costs. Kerbside collection would provide the highest recycling rate, 31% compared to 25% in the baseline scenario, but bring schemes with drop-off containers would also be a reasonable solution. Collection of recyclables at recycling centres was not recommendable because the recycling rate would decrease to 20%. In general, the results showed that enhancing recycling and avoiding incineration was recommendable because the environmental performance was improved in several impact categories. The municipal costs for collection and treatment of waste were reduced with increasing recycling, mainly because the high cost for incineration was avoided. However, solutions for mitigation of air pollution caused by increased collection and transport should be sought.

  17. Peak Demand Reduction with Dual-Source Heat Pumps Using Municipal Water 

    E-Print Network [OSTI]

    Morehouse, J. H.; Khan, J. A.; Connor, L. N.; Pal, D.

    1992-01-01T23:59:59.000Z

    The objective of this project was to examine a dual-source (air and/or water-coupled) heat pump concept which would reduce or eliminate the need for supplemental electrical resistance heating (strip heaters). The project examined two system options...

  18. Peak Demand Reduction with Dual-Source Heat Pumps Using Municipal Water

    E-Print Network [OSTI]

    Morehouse, J. H.; Khan, J. A.; Connor, L. N.; Pal, D.

    The objective of this project was to examine a dual-source (air and/or water-coupled) heat pump concept which would reduce or eliminate the need for supplemental electrical resistance heating (strip heaters). The project examined two system options...

  19. Mayors, Markets and Municipal Reform: The Politics of Water Delivery in Mexico

    E-Print Network [OSTI]

    Herrera, Veronica Maria Sol

    2011-01-01T23:59:59.000Z

    is composed of water extraction, treatment, transportationof the measurements of water extraction, pressure, and allfunctions (measuring water extraction, energy use, water

  20. Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

    SciTech Connect (OSTI)

    Walker, Michael E.; Theregowda, Ranjani B.; Safari, Iman; Abbasian, Javad; Arastoopour, Hamid; Dzombak, David A.; Hsieh, Ming-Kai; Miller, David C.

    2013-10-01T23:59:59.000Z

    A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondarytreated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

  1. Novel Membranes and Systems for Industrial and Municipal Water...

    Energy Savers [EERE]

    Hua Wang, GE Global Research U.S. DOE Advanced Manufacturing Office Program Review Meeting Washington, D.C. May 28-29, 2015 This presentation does not contain any proprietary,...

  2. Wastewater and Wastewater Treatment Systems (Oklahoma)

    Broader source: Energy.gov [DOE]

    The Oklahoma Department of Environmental Quality administers regulations for waste water and waste water treatment systems. Construction of a municipal treatment work, non-industrial waste water...

  3. System for treating produced water

    DOE Patents [OSTI]

    Sullivan, Enid J. (Los Alamos, NM); Katz, Lynn (Austin, TX); Kinney, Kerry (Austin, TX); Bowman, Robert S. (Lemitar, NM); Kwon, Soondong (Kyungbuk, KR)

    2010-08-03T23:59:59.000Z

    A system and method were used to treat produced water. Field-testing demonstrated the removal of contaminants from produced water from oil and gas wells.

  4. Municipal waste processing apparatus

    DOE Patents [OSTI]

    Mayberry, J.L.

    1988-04-13T23:59:59.000Z

    This invention relates to apparatus for processing municipal waste, and more particularly to vibrating mesh screen conveyor systems for removing grit, glass, and other noncombustible materials from dry municipal waste. Municipal waste must be properly processed and disposed of so that it does not create health risks to the community. Generally, municipal waste, which may be collected in garbage trucks, dumpsters, or the like, is deposited in processing areas such as landfills. Land and environmental controls imposed on landfill operators by governmental bodies have increased in recent years, however, making landfill disposal of solid waste materials more expensive. 6 figs.

  5. Sorption of cadmium and lead by clays from municipal incinerator ash-water suspensions

    SciTech Connect (OSTI)

    Roy, W.R.; Krapac, I.G.; Steele, J.D. [Illinois State Geological Survey, Champaign, IL (United States)

    1993-07-01T23:59:59.000Z

    The effect of Cl complexation in extracts of a flue gas-scrubber incinerator fly ash sample on the sorption of Cd and Ph by kaolinite and illite was investigated using batch-sorption methods. In the pH range of 5 to 9, Cl complexation may reduce sorption and thus increase the mobility of these metals. When an ash-water suspension was acidified to pH 6.85, the dissolution of Cl and Ca essentially eliminated Cd sorption because of complexation and cationic competition. Cadmium would be considered as either mobile or very mobile under these conditions. Lead was not soluble in the pH-6.85 suspension. At pH 12, the approximate pH of water in contact with flue gas-scrubber fly ash, Cd was essentially insoluble and Ph occurred as anionic Ph hydroxide. Anionic Ph was sorbed by the two clays, and the extent of sorption was not influenced by Cl or carbonate complexation. Sorption constants, derived from isotherms, suggested that Ph would be relatively immobile in saturated soil-water systems. The recent concern that highly alkaline, flue gas-scrubber fly ash may release environmentally significant concentrations of mobile Ph when placed in an ash-disposal site with a soil liner should be reevaluated in light of this study. 37 refs., 6 figs., 3 tabs.

  6. Mayors, Markets and Municipal Reform: The Politics of Water Delivery in Mexico

    E-Print Network [OSTI]

    Herrera, Veronica Maria Sol

    2011-01-01T23:59:59.000Z

    cycle…there is a lack of water in the city, it threatensbut did not because of lack of water, because they needed aconcerned about the lack of adequate water provision and

  7. Green Systems Solar Hot Water

    E-Print Network [OSTI]

    Schladow, S. Geoffrey

    Green Systems Solar Hot Water Heating the Building Co-generation: Heat Recovery System: Solar panels not enough Generates heat energy Captures heat from generator and transfers it to water Stores Thermal Panels (Trex enclosure) Hot Water Storage Tank (TS-5; basement) Hot Water Heaters (HW-1

  8. Carbon and Water Resource Management for Water Distribution Systems

    E-Print Network [OSTI]

    Hendrickson, Thomas Peter

    2013-01-01T23:59:59.000Z

    4 April, 2013. (4) 2010 Water Use Survey Summary Estimates –State Totals; Texas Water Development Board: Austin, TX,indicators for urban water systems. Urban Water. 2004, 4,

  9. Optimization of Chilled Water Systems

    E-Print Network [OSTI]

    Gidwani, B. N.

    OPTIMIZATION OF CHILLED WATER SYSTEMS B. N. GIDWANI, P.E., Vice President? Roy F. Weston, Inc.?West Chester, Pennsylvania 19380 ABSTRACT Chilled water systems are one of the major energy consumers in industrial, commercial, and institutional... complexes. The centralization of chilled water systems presents numerous advantages, including simplified controls, reduced installation capacity due to diversity, and consolidated maintenance and operation. Centrally chilled water systems present...

  10. Water Heaters and Hot Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    the temperature of the residual water encountered by theof hot water and the residual water might occur: (1) thehot water might drive the residual water through the piping

  11. Water Heaters and Hot Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    Transportation Water Heaters and Hot Water DistributionLaboratory). 2008. Water Heaters and Hot Water Distributionfor instantaneous gas water heaters; and pressure loss

  12. Central Multifamily Water Heating Systems

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Building America Program is hosting a no-cost, webinar-based training on Central Multifamily Water Heating Systems. The webinar will focus the effective use of central heat pump water heaters...

  13. CLIMATE CHANGE IMPACTS ON MUNICIPAL, MINING, AND AGRICULTURAL WATER SUPPLIES IN CHILE

    E-Print Network [OSTI]

    NorthernAmericanmarketduring winter. This region relies entirely on snow and ice- melt streams to provide irrigation water. Santiago-likeareas,humidsubtropicalregions, temperate zones, oceanic-dominated climates, sub- polar areas, alpine tundra, and ice caps. These climates

  14. Carbon and Water Resource Management for Water Distribution Systems

    E-Print Network [OSTI]

    Hendrickson, Thomas Peter

    2013-01-01T23:59:59.000Z

    23 4.5 Water-Energy SustainabilityWater Distribution System Water-energy Sustainability ToolWastewater-energy Sustainability Tool v   Acknowledgements

  15. Combined Municipal Solid Waste and biomass system optimization for district energy applications

    SciTech Connect (OSTI)

    Rentizelas, Athanasios A., E-mail: arent@central.ntua.gr; Tolis, Athanasios I., E-mail: atol@central.ntua.gr; Tatsiopoulos, Ilias P., E-mail: itat@central.ntua.gr

    2014-01-15T23:59:59.000Z

    Highlights: • Combined energy conversion of MSW and agricultural residue biomass is examined. • The model optimizes the financial yield of the investment. • Several system specifications are optimally defined by the optimization model. • The application to a case study in Greece shows positive financial yield. • The investment is mostly sensitive on the interest rate, the investment cost and the heating oil price. - Abstract: Municipal Solid Waste (MSW) disposal has been a controversial issue in many countries over the past years, due to disagreement among the various stakeholders on the waste management policies and technologies to be adopted. One of the ways of treating/disposing MSW is energy recovery, as waste is considered to contain a considerable amount of bio-waste and therefore can lead to renewable energy production. The overall efficiency can be very high in the cases of co-generation or tri-generation. In this paper a model is presented, aiming to support decision makers in issues relating to Municipal Solid Waste energy recovery. The idea of using more fuel sources, including MSW and agricultural residue biomass that may exist in a rural area, is explored. The model aims at optimizing the system specifications, such as the capacity of the base-load Waste-to-Energy facility, the capacity of the peak-load biomass boiler and the location of the facility. Furthermore, it defines the quantity of each potential fuel source that should be used annually, in order to maximize the financial yield of the investment. The results of an energy tri-generation case study application at a rural area of Greece, using mixed MSW and biomass, indicate positive financial yield of investment. In addition, a sensitivity analysis is performed on the effect of the most important parameters of the model on the optimum solution, pinpointing the parameters of interest rate, investment cost and heating oil price, as those requiring the attention of the decision makers. Finally, the sensitivity analysis is enhanced by a stochastic analysis to determine the effect of the volatility of parameters on the robustness of the model and the solution obtained.

  16. Municipal Consortium Releases Updated Model Specification for Networked Outdoor Lighting Control Systems

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy's Municipal Solid-State Street Lighting Consortium (MSSLC) has released an update to its Model Specification for Adaptive Control and Remote Monitoring of LED Roadway...

  17. Protected Water Area System (Iowa)

    Broader source: Energy.gov [DOE]

    The Natural Resource Commission maintains a state plan for the design and establishment of a protected water area system and those adjacent lands needed to protect the integrity of that system. A...

  18. Water Heaters and Hot Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    efficient gas water heating appliance to market; a plan toefficient gas water heating appliance to market; and to planefficient gas water heating appliance to market; and 3) to

  19. Water Heaters and Hot Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    24 Figure 7. Comparison of Daily Water Heater28 Figure 8. Monitored Field Efficiency of Tankless Water28 Figure 9. Monitored Lab Efficiency of Tankless Water

  20. Water Heaters and Hot Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    step in developing a realistic degradation term for tankless water heatersstep (water draw event) in the simulation. Instantaneous Gas Water Heater

  1. Optimization of Chilled Water Systems

    E-Print Network [OSTI]

    Gidwani, B. N.

    1984-01-01T23:59:59.000Z

    OPTIMIZATION OF CHILLED WATER SYSTEMS central 0 e m a In 8. N. Gidwani, P.E. Project Director Roy F. Weston, Inc. West Chester. Pennsylvania 19380 ABSTRACT Chilled water systems are one of the major energy consumers in industrial... manually, using a prescribed operating pro- cedure for each load level, or through automatic controls. The system configuration plays an important role in establishing the economics of sequencing. For example, sequencing of chillers in series...

  2. Co-gasification of municipal solid waste and material recovery in a large-scale gasification and melting system

    SciTech Connect (OSTI)

    Tanigaki, Nobuhiro, E-mail: tanigaki.nobuhiro@nsc-eng.co.jp [Nippon Steel Engineering Co., Ltd. (Head Office), Osaki Center Building 1-5-1, Osaki, Shinagawa-ku, Tokyo 141-8604 (Japan); Manako, Kazutaka [Nippon Steel Engineering Co., Ltd., 46-59, Nakabaru, Tobata-ku, Kitakyushu, Fukuoka 804-8505 (Japan); Osada, Morihiro [Nippon Steel Engineering Co., Ltd. (Head Office), Osaki Center Building 1-5-1, Osaki, Shinagawa-ku, Tokyo 141-8604 (Japan)

    2012-04-15T23:59:59.000Z

    Highlights: Black-Right-Pointing-Pointer This study evaluates the effects of co-gasification of MSW with MSW bottom ash. Black-Right-Pointing-Pointer No significant difference between MSW treatment with and without MSW bottom ash. Black-Right-Pointing-Pointer PCDD/DFs yields are significantly low because of the high carbon conversion ratio. Black-Right-Pointing-Pointer Slag quality is significantly stable and slag contains few hazardous heavy metals. Black-Right-Pointing-Pointer The final landfill amount is reduced and materials are recovered by DMS process. - Abstract: This study evaluates the effects of co-gasification of municipal solid waste with and without the municipal solid waste bottom ash using two large-scale commercial operation plants. From the viewpoint of operation data, there is no significant difference between municipal solid waste treatment with and without the bottom ash. The carbon conversion ratios are as high as 91.7% and 95.3%, respectively and this leads to significantly low PCDD/DFs yields via complete syngas combustion. The gross power generation efficiencies are 18.9% with the bottom ash and 23.0% without municipal solid waste bottom ash, respectively. The effects of the equivalence ratio are also evaluated. With the equivalence ratio increasing, carbon monoxide concentration is decreased, and carbon dioxide and the syngas temperature (top gas temperature) are increased. The carbon conversion ratio is also increased. These tendencies are seen in both modes. Co-gasification using the gasification and melting system (Direct Melting System) has a possibility to recover materials effectively. More than 90% of chlorine is distributed in fly ash. Low-boiling-point heavy metals, such as lead and zinc, are distributed in fly ash at rates of 95.2% and 92.0%, respectively. Most of high-boiling-point heavy metals, such as iron and copper, are distributed in metal. It is also clarified that slag is stable and contains few harmful heavy metals such as lead. Compared with the conventional waste management framework, 85% of the final landfill amount reduction is achieved by co-gasification of municipal solid waste with bottom ash and incombustible residues. These results indicate that the combined production of slag with co-gasification of municipal solid waste with the bottom ash constitutes an ideal approach to environmental conservation and resource recycling.

  3. Carbon and Water Resource Management for Water Distribution Systems

    E-Print Network [OSTI]

    Hendrickson, Thomas Peter

    2013-01-01T23:59:59.000Z

    Reliability Corporation Polyethylene Polyvinyl chloride Society of Environmental Toxicology and Chemistry Water Distribution System

  4. 1.85 Water and Wastewater Treatment Engineering, Spring 2005

    E-Print Network [OSTI]

    Shanahan, Peter

    Theory and design of systems for treating industrial and municipal wastewater and potable water supplies. Methods for characterizing wastewater properties. Physical, chemical, and biological processes, including primary ...

  5. Municipal Support of Projects (Iowa)

    Broader source: Energy.gov [DOE]

    Municipalities may choose to support projects, such as those which will generate electricity through the use of a renewable energy source, by tax-exempt bond financing; easements for roads, water...

  6. Municipal Waste Planning, Recycling and Waste Reduction Act (Pennsylvania)

    Broader source: Energy.gov [DOE]

    This act provides for planning for the processing and disposal of municipal waste; requires counties to submit plans for municipal waste management systems within their boundaries; authorizes...

  7. Development of a Web-based Emissions Reduction Calculator for Retrofits to Municipal Water Supply and Waste Water Facilities

    E-Print Network [OSTI]

    Baltazar-Cervantes, J. C.; Liu, Z.; Gilman, D.; Haberl, J. S.; Culp, C.

    2005-01-01T23:59:59.000Z

    -------------------------------------- Ycp = 6.9610 ( 0.4799) LS = 0.0000 ( 0.0000) RS = 0.1864 ( 0.0262) Post-Retrofit ESL-IC-10/05-32 wice by Figure 2, t-03 v-03 alized water use for the city using a 3- nge-point linear model... against average riod temperature for the 2002 pre-retrofit h), and 2003 post retrofit period (right t, thru IMT it is determined the ce of the facility using a 4-parameter Xcp = 55.0408 ( 0...

  8. Water in clay-water systems (1) Philip F. LOW

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Water in clay-water systems (1) Philip F. LOW Department of Agronomy, Purdue University. Agric. Exp. Stn., West Lafayette, IN 47907, U.S.A. SUMMARY The swelling of clay-water systems and the thermodynamic, hydrodynamic and spectroscopic properties of water in these systems are discussed. The swelling

  9. Integrated Planning for Water and Energy Systems

    E-Print Network [OSTI]

    Keller, Arturo A.

    of water in a specific location. #12;Water Extraction & Conveyance Water Treatment End-Use AgriculturalIntegrated Planning for Water and Energy Systems Integrated Planning for Water and Energy Systems Wilkinson, Ph.D. Director, Water Policy Program Bren School of Environmental Science and Management

  10. A better cooling water system

    SciTech Connect (OSTI)

    Gale, T.E.; Beecher, J.

    1987-12-01T23:59:59.000Z

    To prepare their newly constructed reduced crude conversion (RCC) open recirculating cooling water system for the implementation of a corrosion and deposit control water treatment program, Ashland Petroleum, Catlettsburg, Ky., made plans for and carried out precleaning and passivation procedures. Here, the authors share the results, and some potential guidelines for one's own operations. Inspection of equipment after precleaning showed that the precleaning procedures was very effective in removing undesirable matter. After precleaning and passivation of the system, the recommended cooling water treatment program was started. Corrosion rates for mild steel specimens ranged from 0.5 to 1.5 mils per year (mpy), with an average of 1.0 mpy. The corrosion rates for admiralty specimens ranged from 0.1 to 0.2 mpy. Benefits of the precleaning and passivating programs greatly outweigh the costs, since the normal cooling water treatment program for corrosion and deposit control can then operate more effectively.

  11. Information Sources for Small Water Systems 

    E-Print Network [OSTI]

    Dozier, Monty; Theodori, Gene L.; Jensen, Ricard

    2007-02-19T23:59:59.000Z

    Managers of small waters systems must have information about a variety of topics. This publication lists essential printed and electronic resources on disaster preparedness, national drinking water standards, private water well management, water...

  12. Water Heaters and Hot Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    heat loss testing; part load performance curves for instantaneous gas water heaters; and pressure loss calculationsheat loss testing; part load performance curves for instantaneous gas water heaters; and pressure loss calculations

  13. Information Sources for Small Water Systems

    E-Print Network [OSTI]

    Dozier, Monty; Theodori, Gene L.; Jensen, Ricard

    2007-02-19T23:59:59.000Z

    E - 4 3 8 0 2 - 0 7 ?The protection of water quality is vital for managers of small water systems.? Information S o urces for Small Water System s Monty Dozier, Associate Professor and Extension Specialist; Gene Theodori, Associate Professor... and Extension Program Leader; and Ric Jensen, Assistant Research Scientist, Texas Water Resources Institute, The Texas A&M University T The protection of water quality is vital for managers of small water systems. Ample resources related to water quality...

  14. SMUD- Solar Water Heater Rebate Program

    Broader source: Energy.gov [DOE]

    The Sacramento Municipal Utility District's (SMUD) Solar Domestic Hot Water Program provides rebates and/or loan financing to customers who install solar water heating systems. The amount of the...

  15. Decentralization of Water Service Delivery in Mexico: The Effects of Party Politics, Intergovernmental Dynamics, and Municipal Capacity

    E-Print Network [OSTI]

    Hastings, Cameron Jones

    2011-01-01T23:59:59.000Z

    impacted by the lack of clean water. The percentage of thestatistics regarding lack of access to water and the impactspopulation lacks access to high quality water services. The

  16. WATER DISTRIBUTION SYSTEM OPERATION: APPLICATION OF

    E-Print Network [OSTI]

    Mays, Larry W.

    CHAPTER 5 WATER DISTRIBUTION SYSTEM OPERATION: APPLICATION OF SIMULATED ANNEALING Fred E. Goldman Arizona State University, Tempe, Arizona 5.1 INTRODUCTION The operation of water distribution systems affects the water quality in these systems. EPA regulations require that water quality be maintained

  17. Water Resource System Optimization by Geometric Programming

    E-Print Network [OSTI]

    Meier, W. L.; Shih, C. S.; Wray, D. J.

    Water resources planners and systems analysts are continually confronted with many complex optimization problems. Two major factors contribute to this problem. Firstly, mathematical modeling and system description capabilities in water resources...

  18. Is Dilution The Solution To Pollution? Municipal Sewerage Systems In Late Nineteenth Century San Francisco And London

    E-Print Network [OSTI]

    Smith, Brooke Ray

    2007-01-01T23:59:59.000Z

    the concept of biological treatment of wastewater, whichwastewater treatment planning. Contrasting Paradigms: Biologicalbiological treatment, incorporating ecological, social, and economic benefits into municipal wastewater

  19. Clemson University Water System System No, SC3910006

    E-Print Network [OSTI]

    Duchowski, Andrew T.

    intended to reduce the level of a contaminant in drinking water. Maximum Residual Disinfectant Level1 Clemson University Water System System No, SC3910006 Clemson, SC 2008 Annual Water-Quality Report and reliable supply of high-quality drinking water. We test our water using sophisticated equipment

  20. Clemson University Water System System No, SC3910006

    E-Print Network [OSTI]

    Duchowski, Andrew T.

    intended to reduce the level of a contaminant in drinking water. Maximum Residual Disinfectant Level1 Clemson University Water System System No, SC3910006 Clemson, SC 2004 Annual Water-Quality Report with a safe and reliable supply of high-quality drinking water. We test our water using sophisticated

  1. Clemson University Water System System No, SC3910006

    E-Print Network [OSTI]

    Duchowski, Andrew T.

    intended to reduce the level of a contaminant in drinking water. Maximum Residual Disinfectant Level1 Clemson University Water System System No, SC3910006 Clemson, SC 2005 Annual Water-Quality Report with a safe and reliable supply of high-quality drinking water. We test our water using sophisticated

  2. Clemson University Water System System No, SC3910006

    E-Print Network [OSTI]

    Duchowski, Andrew T.

    of microbial contaminants. Maximum Residual Disinfectant Level Goal or (MRDLG): The level of drinking water1 Clemson University Water System System No, SC3910006 Clemson, SC 2007 Annual Water-Quality Report with a safe and reliable supply of high-quality drinking water. We test our water using sophisticated

  3. Fant's Grove Water System System No, SC390112

    E-Print Network [OSTI]

    Duchowski, Andrew T.

    intended to reduce the level of a contaminant in drinking water. Maximum Residual Disinfectant Level1 Fant's Grove Water System System No, SC390112 Clemson, SC 2003 Annual Water-Quality Report with a safe and reliable supply of high-quality drinking water. We test our water using sophisticated

  4. Clemson University Water System System No, SC3910006

    E-Print Network [OSTI]

    Duchowski, Andrew T.

    of microbial contaminants. Maximum Residual Disinfectant Level Goal or (MRDLG): The level of drinking water1 Clemson University Water System System No, SC3910006 Clemson, SC 2006 Annual Water-Quality Report with a safe and reliable supply of high-quality drinking water. We test our water using sophisticated

  5. Clemson University Water System System No, SC3910006

    E-Print Network [OSTI]

    Duchowski, Andrew T.

    intended to reduce the level of a contaminant in drinking water. Maximum Residual Disinfectant Level1 Clemson University Water System System No, SC3910006 Clemson, SC 2003 Annual Water-Quality Report with a safe and reliable supply of high-quality drinking water. We test our water using sophisticated

  6. Fant's Grove Water System System No, SC390112

    E-Print Network [OSTI]

    Duchowski, Andrew T.

    intended to reduce the level of a contaminant in drinking water. Maximum Residual Disinfectant Level1 Fant's Grove Water System System No, SC390112 Clemson, SC 2004 Annual Water-Quality Report with a safe and reliable supply of high-quality drinking water. We test our water using sophisticated

  7. Water reactive hydrogen fuel cell power system

    DOE Patents [OSTI]

    Wallace, Andrew P; Melack, John M; Lefenfeld, Michael

    2014-01-21T23:59:59.000Z

    A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into a fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.

  8. Water reactive hydrogen fuel cell power system

    DOE Patents [OSTI]

    Wallace, Andrew P; Melack, John M; Lefenfeld, Michael

    2014-11-25T23:59:59.000Z

    A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into the fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.

  9. Lassen Municipal Utility District- PV Rebate Program

    Broader source: Energy.gov [DOE]

    Lassen Municipal Utility District (LMUD) is providing incentives for its customers to purchase solar electric photovoltaic (PV) systems. Rebate levels will decrease annually over the life of the...

  10. Stealthy Deception Attacks on Water SCADA Systems

    E-Print Network [OSTI]

    Hu, Fei

    Stealthy Deception Attacks on Water SCADA Systems Saurabh Amin1 Xavier Litrico2 Alexandre M. Bayen1 The Gignac Water SCADA System Modeling of Cascade Canal Pools Attacks on PI Control Limits on Stability and Detectability #12;Recapitulation from last year The Gignac Water SCADA System Modeling of Cascade Canal Pools

  11. Economies of Size in Municipal Water-Treatment Technologies: A Texas Lower Rio Grande Valley Case Study 

    E-Print Network [OSTI]

    Boyer, Christopher N.; Rister, M. Edward; Rogers, Callie S.; Sturdivant, Allen W.; Lacewell, Ronald D.; Browning, Charles Jr.; Elium III, James R.; Seawright, Emily K.

    2010-01-01T23:59:59.000Z

    . In recent years, however, technological advancements have improved the economic viability of reverse-osmosis (RO) desalination of brackish-groundwater as a potable water source. By including brackishgroundwater, there may be an alternative water source...

  12. Development of a purpose built landfill system for the control of methane emissions from municipal solid waste

    E-Print Network [OSTI]

    Columbia University

    solid waste Sudhakar Yedla*, Jyoti K. Parikh Indira Gandhi Institute of Development Research, Vaidya (PBLF) has been proposed for the control of methane emissions from municipal solid waste (MSW Generation of municipal solid waste (MSW) increases with socio-economic development. In developing coun

  13. Web-GIS oriented systems viability for municipal solid waste selective collection optimization in developed and transient economies

    SciTech Connect (OSTI)

    Rada, E.C., E-mail: Elena.Rada@ing.unitn.it [University of Trento, Department of Civil, Environmental and Mechanical Engineering, Via Mesiano, 77, 38123 Trento (Italy); Ragazzi, M. [University of Trento, Department of Civil, Environmental and Mechanical Engineering, Via Mesiano, 77, 38123 Trento (Italy); Fedrizzi, P. [I and S, Informatica e Servizi srl, Via Solteri, 74, 38121 Trento (Italy)

    2013-04-15T23:59:59.000Z

    Highlights: ? As an appropriate solution for MSW management in developed and transient countries. ? As an option to increase the efficiency of MSW selective collection. ? As an opportunity to integrate MSW management needs and services inventories. ? As a tool to develop Urban Mining actions. - Abstract: Municipal solid waste management is a multidisciplinary activity that includes generation, source separation, storage, collection, transfer and transport, processing and recovery, and, last but not least, disposal. The optimization of waste collection, through source separation, is compulsory where a landfill based management must be overcome. In this paper, a few aspects related to the implementation of a Web-GIS based system are analyzed. This approach is critically analyzed referring to the experience of two Italian case studies and two additional extra-European case studies. The first case is one of the best examples of selective collection optimization in Italy. The obtained efficiency is very high: 80% of waste is source separated for recycling purposes. In the second reference case, the local administration is going to be faced with the optimization of waste collection through Web-GIS oriented technologies for the first time. The starting scenario is far from an optimized management of municipal solid waste. The last two case studies concern pilot experiences in China and Malaysia. Each step of the Web-GIS oriented strategy is comparatively discussed referring to typical scenarios of developed and transient economies. The main result is that transient economies are ready to move toward Web oriented tools for MSW management, but this opportunity is not yet well exploited in the sector.

  14. Distrbuted Sensing Systems for Water Quality Assesment and Management

    E-Print Network [OSTI]

    2007-01-01T23:59:59.000Z

    Sensing Systems for Water Quality Assessment and ManagementSensing Systems for Water Quality Assessment and ManagementSensing Systems for Water Quality Assessment and Management

  15. Rate Setting for Small Water Systems 

    E-Print Network [OSTI]

    Dozier, Monty; Theodori, Gene L.; Jensen, Ricard

    2007-03-28T23:59:59.000Z

    Jensen, Assistant Research Scientist, Texas Water Resources Institute; The Texas A&M University System K Knowing how to set the proper rate for water service is a daunting challenge for small water systems. The rates must be high enough to re- cover...

  16. Resources for Small Water Systems in Texas 

    E-Print Network [OSTI]

    Dozier, Monty; Theodori, Gene L.; Jensen, Ricard

    2007-03-28T23:59:59.000Z

    and Extension Specialist; Monty Dozier, Assistant Professor and Extension Specialist; and Ric Jensen, Assistant Research Scientist, Texas Water Resources Institute; The Texas A&M University System There are many resources to help managers of small water...

  17. Rate Setting for Small Water Systems

    E-Print Network [OSTI]

    Dozier, Monty; Theodori, Gene L.; Jensen, Ricard

    2007-03-28T23:59:59.000Z

    Knowing how to set the proper rate for water service is a challenge for small water systems. They must generate enough revenue to remain solvent, but offer affordable service. This publication describes the various types of rates and explains...

  18. The Potential of Cellulosic Ethanol Production from Municipal Solid Waste: A Technical and Economic Evaluation

    E-Print Network [OSTI]

    Shi, Jian; Ebrik, Mirvat; Yang, Bin; Wyman, Charles E.

    2009-01-01T23:59:59.000Z

    e.g. waste water treatment, solid waste combustion) weretreatments. Results and Discussions Cellulosic MSW Feedstocks Municipal solid waste (

  19. System for removal of arsenic from water

    DOE Patents [OSTI]

    Moore, Robert C.; Anderson, D. Richard

    2004-11-23T23:59:59.000Z

    Systems for removing arsenic from water by addition of inexpensive and commonly available magnesium oxide, magnesium hydroxide, calcium oxide, or calcium hydroxide to the water. The hydroxide has a strong chemical affinity for arsenic and rapidly adsorbs arsenic, even in the presence of carbonate in the water. Simple and commercially available mechanical systems for removal of magnesium hydroxide particles with adsorbed arsenic from drinking water can be used, including filtration, dissolved air flotation, vortex separation, or centrifugal separation. A system for continuous removal of arsenic from water is provided. Also provided is a system for concentrating arsenic in a water sample to facilitate quantification of arsenic, by means of magnesium or calcium hydroxide adsorption.

  20. Development of a Segregated Municipal Solid Waste Gasification System for Electrical Power Generation

    E-Print Network [OSTI]

    Maglinao, Amado Latayan

    2013-04-11T23:59:59.000Z

    ) gasification for electrical power generation was conducted in a fluidized bed gasifier and the feasibility of using a control system was evaluated to facilitate its management and operation. The performance of an engine using the gas produced was evaluated. A...

  1. Decision process for the retrofit of municipal buildings with solar energy systems: a technical guide

    SciTech Connect (OSTI)

    Licciardello, Michael R.; Wood, Brian; Dozier, Warner; Braly, Mark; Yates, Alan

    1980-11-01T23:59:59.000Z

    As a background for solar applications, the following topics are covered: solar systems and components for retrofit installations; cost, performance, and quality considerations; and financing alternatives for local government. The retrofit decision process is discussed as follows: pre-screening of buildings, building data requirements, the energy conservation audit, solar system sizing and economics, comparison of alternatives, and implementation. Sample studies are presented for the West Valley Animal Shelter and the Hollywood Police Station. (MHR)

  2. A multi-echelon supply chain model for municipal solid waste management system

    SciTech Connect (OSTI)

    Zhang, Yimei, E-mail: yimei.zhang1@gmail.com [Energy and Environmental Research Academy, North China Electric Power University, Beijing 102206 (China); Huang, Guo He [Environmental Systems Engineering Program, Faculty of Engineering and Applied Science, University of Regina, Regina, Saskatchewan S4S 0A2 (Canada); He, Li [Energy and Environmental Research Academy, North China Electric Power University, Beijing 102206 (China)

    2014-02-15T23:59:59.000Z

    In this paper, a multi-echelon multi-period solid waste management system (MSWM) was developed by inoculating with multi-echelon supply chain. Waste managers, suppliers, industries and distributors could be engaged in joint strategic planning and operational execution. The principal of MSWM system is interactive planning of transportation and inventory for each organization in waste collection, delivery and disposal. An efficient inventory management plan for MSWM would lead to optimized productivity levels under available capacities (e.g., transportation and operational capacities). The applicability of the proposed system was illustrated by a case with three cities, one distribution and two waste disposal facilities. Solutions of the decision variable values under different significant levels indicate a consistent trend. With an increased significant level, the total generated waste would be decreased, and the total transported waste through distribution center to waste to energy and landfill would be decreased as well.

  3. Economies of Size in Municipal Water-Treatment Technologies: A Texas Lower Rio Grande Valley Case Study

    E-Print Network [OSTI]

    Boyer, Christopher N.; Rister, M. Edward; Rogers, Callie S.; Sturdivant, Allen W.; Lacewell, Ronald D.; Browning, Charles Jr.; Elium III, James R.; Seawright, Emily K.

    in 2004 (Rogers 2008; Rogers et al. 2010). Similarly, recognizing the diversification benefits and estimated cost competitiveness of brackish-groundwater desalination, the City of Brownsville, TX built the 7.5 mgd Southmost brackish...-groundwater desalination facility in 2004. This alternative-technology adoption is intended to reduce the City of Brownsville?s reliance on the Rio Grande (Sturdivant et al. 2009). Further, the Olmito Water Supply Corporation (OWSC) in Olmito, TX (directly north...

  4. Water turbine system and method of operation

    DOE Patents [OSTI]

    Costin, Daniel P. (Montpelier, VT)

    2011-05-10T23:59:59.000Z

    A system for providing electrical power from a current turbine is provided. The system includes a floatation device and a mooring. A water turbine structure is provided having an upper and lower portion wherein the lower portion includes a water fillable chamber. A plurality of cables are used to couple the system where a first cable couples the water turbine to the mooring and a second cable couples the floatation device to the first cable. The system is arranged to allow the turbine structure to be deployed and retrieved for service, repair, maintenance and redeployment.

  5. Water turbine system and method of operation

    DOE Patents [OSTI]

    Costin, Daniel P.

    2010-06-15T23:59:59.000Z

    A system for providing electrical power from a current turbine is provided. The system includes a floatation device and a mooring. A water turbine structure is provided having an upper and lower portion wherein the lower portion includes a water fillable chamber. A plurality of cables are used to couple the system where a first cable couples the water turbine to the mooring and a second cable couples the floatation device to the first cable. The system is arranged to allow the turbine structure to be deployed and retrieved for service, repair, maintenance and redeployment.

  6. Water turbine system and method of operation

    DOE Patents [OSTI]

    Costin, Daniel P. (Montpelier, VT)

    2009-02-10T23:59:59.000Z

    A system for providing electrical power from a current turbine is provided. The system includes a floatation device and a mooring. A water turbine structure is provided having an upper and lower portion wherein the lower portion includes a water fillable chamber. A plurality of cables are used to couple the system where a first cable couples the water turbine to the mooring and a second cable couples the floatation device to the first cable. The system is arranged to allow the turbine structure to be deployed and retrieved for service, repair, maintenance and redeployment.

  7. Concord Municipal Light Plant- Solar Rebate Program

    Broader source: Energy.gov [DOE]

    Concord Municipal Light Plant (CMLP) offers rebates to customers who install solar photovoltaic (PV) systems that are designed to offset the customer's electrical needs. Systems must be owned by...

  8. Robot design for leak detection in water-pipe systems

    E-Print Network [OSTI]

    Choi, Changrak

    2012-01-01T23:59:59.000Z

    Leaks are major problem that occur in the water pipelines all around the world. Several reports indicate loss of around 20 to 30 percent of water in the distribution of water through water pipe systems. Such loss of water ...

  9. Metals in Municipal Landfill Leachate And Their Health Effects

    E-Print Network [OSTI]

    Laughlin, Robert B.

    raw leachate contains concentrations of heavy metals in excess ofthe drinking water standards of the un- saturated zone. If municipal solid waste is placed di- rectly into ground water, or if leachateMetals in Municipal Landfill Leachate And Their Health Effects STEPHEN C. JAMES, BS, MSCE Abstract

  10. High temperature hot water systems: A primer

    SciTech Connect (OSTI)

    Govan, F.A. [NMD and Associates, Cincinnati, OH (United States)

    1998-01-01T23:59:59.000Z

    The fundamental principles of high temperature water (HTW) system technology and its advantages for thermal energy distribution are presented. Misconceptions of this technology are also addressed. The paper describes design principles, applications, HTW properties, HTW system advantages, selecting the engineer, load diversification, design temperatures, system pressurization, pump considerations, constant vs. VS pumps, HTW generator types, and burners and controls.

  11. Resources for Small Water Systems in Texas

    E-Print Network [OSTI]

    Dozier, Monty; Theodori, Gene L.; Jensen, Ricard

    2007-03-28T23:59:59.000Z

    This publication is a guide to finding the many resources available to help managers of small water systems in Texas. Details are provided about sources of financial assistance, tools for capacity building, training programs and educational...

  12. Renewable Energy Powered Water Treatment Systems 

    E-Print Network [OSTI]

    Richards, Bryce S.; Schäfer, Andrea

    2009-01-01T23:59:59.000Z

    There are many motivations for choosing renewable energy technologies to provide the necessary energy to power water treatment systems for reuse and desalination. These range from the lack of an existing electricity grid, ...

  13. Implementation of a Geographic Information System for municipal water quality assurance

    E-Print Network [OSTI]

    Murphy, Eileen Marie

    1996-01-01T23:59:59.000Z

    Implementing a GIS. Maximizing the Potential of a GIS. . Cooperative Planning. . VH: CONCLUSIONS. References. 13 14 14 15 15 17 18 20 21 23 25 71 LIST OF FIGURES Figure 1: Locauon of the Green River watershed. Figure 2: Portion of QA... are listed by ESRI as data sources for ArcView: TIFF, ERDAS, BSQ, BIL, and BIF files; Sun rasterfiles; and run-length compressed files. Tabular data, either directly displayed or joined to existing spatial data, can be data from database servers...

  14. Novel Membranes and Systems for Industrial and Municipal Water Purification and Reuse

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking ofOilNEW HAMPSHIREofNewsletterEnergySeptember 16,Departmentthe|NovelHua

  15. A Drop in the Bucket: Ten Years of Government Spending on Water and Wastewater Infrastructure in Texas Colonias

    E-Print Network [OSTI]

    Rapier, Richard Edward

    2011-02-22T23:59:59.000Z

    infrastructure improvements than water service in addition to greater allocation to municipal systems that extended service into colonia areas historically operated by water service corporations. Further research may build on this data as well as regional...

  16. River Falls Municipal Utilities- Distributed Solar Tariff

    Broader source: Energy.gov [DOE]

    River Falls Municipal Utilities (RFMU), a member of WPPI Energy, offers a special energy purchase rate to its customers that generate electricity using solar photovoltaic (PV) systems. The special...

  17. Lake Worth Utilities- Residential Solar Water Heating Rebate Program

    Broader source: Energy.gov [DOE]

    The City of Lake Worth Utilities (CLWU), in conjunction with Florida Municipal Power Agency, offers rebates to customers who purchase and install a solar water heating system for residential use. A...

  18. Webinar: ENERGY STAR Hot Water Systems for High Performance Homes...

    Energy Savers [EERE]

    Webinar: ENERGY STAR Hot Water Systems for High Performance Homes Webinar: ENERGY STAR Hot Water Systems for High Performance Homes This presentation is from the Building America...

  19. Municipal Utility Districts (Texas)

    Broader source: Energy.gov [DOE]

    Municipal Utility Districts, regulated by the Texas Commission on Environmental Quality, may be created for the following purposes: (1) the control, storage, preservation, and distribution of its...

  20. STATE OF CALIFORNIA AIR, WATER SIDE SYSTEM, SERVICE HOT WATER & POOL REQUIREMENTS

    E-Print Network [OSTI]

    Certified Water Heater §111, §113 (a) Water Heater Efficiency §113 (b) Service Water Heating Installation/A" in the column next to the measure. 2: For each water heater, pool heat and domestic water loop (or groupsSTATE OF CALIFORNIA AIR, WATER SIDE SYSTEM, SERVICE HOT WATER & POOL REQUIREMENTS CEC-MECH-2C

  1. In-situ continuous water monitoring system

    DOE Patents [OSTI]

    Thompson, C.V.; Wise, M.B.

    1998-03-31T23:59:59.000Z

    An in-situ continuous liquid monitoring system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container by the flow of carrier gas into the liquid directing device. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectrometer and the volatile components are continuously analyzed by the mass spectrometer. 2 figs.

  2. In-situ continuous water monitoring system

    DOE Patents [OSTI]

    Thompson, Cyril V. (Knoxville, TN); Wise, Marcus B. (Kingston, TN)

    1998-01-01T23:59:59.000Z

    An in-situ continuous liquid monitoring system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container by the flow of carrier gas into the liquid directing device. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectrometer and the volatile components are continuously analyzed by the mass spectrometer.

  3. Municipal Water Pollution Control (Minnesota)

    Broader source: Energy.gov [DOE]

    This statute applies to a city, sanitary district, or other governmental subdivision or public corporation. The statute gives the Pollution Control Agency the authority to prepare and enforce a...

  4. High temperature hot water distribution system study

    SciTech Connect (OSTI)

    NONE

    1996-12-01T23:59:59.000Z

    The existing High Temperature Hot Water (HTHW) Distribution System has been plagued with design and construction deficiencies since startup of the HTHW system, in October 1988. In October 1989, after one year of service, these deficiencies were outlined in a technical evaluation. The deficiencies included flooded manholes, sump pumps not hooked up, leaking valves, contaminated HTHW water, and no cathodic protection system. This feasibility study of the High Temperature Hot Water (HTHW) Distribution System was performed under Contract No. DACA0l-94-D-0033, Delivery Order 0013, Modification 1, issued to EMC Engineers, Inc. (EMC), by the Norfolk District Corps of Engineers, on 25 April 1996. The purpose of this study was to determine the existing conditions of the High Temperature Hot Water Distribution System, manholes, and areas of containment system degradation. The study focused on two areas of concern, as follows: * Determine existing conditions and areas of containment system degradation (leaks) in the underground carrier pipes and protective conduit. * Document the condition of underground steel and concrete manholes. To document the leaks, a site survey was performed, using state-of-the-art infrared leak detection equipment and tracer gas leak detection equipment. To document the condition of the manholes, color photographs were taken of the insides of 125 manholes, and notes were made on the condition of these manholes.

  5. Water injected fuel cell system compressor

    DOE Patents [OSTI]

    Siepierski, James S. (Williamsville, NY); Moore, Barbara S. (Victor, NY); Hoch, Martin Monroe (Webster, NY)

    2001-01-01T23:59:59.000Z

    A fuel cell system including a dry compressor for pressurizing air supplied to the cathode side of the fuel cell. An injector sprays a controlled amount of water on to the compressor's rotor(s) to improve the energy efficiency of the compressor. The amount of water sprayed out the rotor(s) is controlled relative to the mass flow rate of air inputted to the compressor.

  6. Energy optimization of water distribution system

    SciTech Connect (OSTI)

    Not Available

    1993-02-01T23:59:59.000Z

    In order to analyze pump operating scenarios for the system with the computer model, information on existing pumping equipment and the distribution system was collected. The information includes the following: component description and design criteria for line booster stations, booster stations with reservoirs, and high lift pumps at the water treatment plants; daily operations data for 1988; annual reports from fiscal year 1987/1988 to fiscal year 1991/1992; and a 1985 calibrated KYPIPE computer model of DWSD`s water distribution system which included input data for the maximum hour and average day demands on the system for that year. This information has been used to produce the inventory database of the system and will be used to develop the computer program to analyze the system.

  7. Hot Water Heating System Operation and Energy Conservation

    E-Print Network [OSTI]

    Shao, Z.; Chen, H.; Wei, P.

    2006-01-01T23:59:59.000Z

    Based on an example of the reconstruction of a hot water heating system, this paper provides an analysis and comparison of the operations of hot water heating systems, including supply water temperature adjustment, flow adjustment during each...

  8. Introduction of Heat Recovery Chiller Control and Water System Design

    E-Print Network [OSTI]

    Jia, J.

    2006-01-01T23:59:59.000Z

    The styles, feature and main concerns of heat recovery water system are discussed, and the entering condenser water temperature control is recommended for higher chiller efficiency and reliable operation. Three optimized water system designs...

  9. Introduction of Heat Recovery Chiller Control and Water System Design 

    E-Print Network [OSTI]

    Jia, J.

    2006-01-01T23:59:59.000Z

    The styles, feature and main concerns of heat recovery water system are discussed, and the entering condenser water temperature control is recommended for higher chiller efficiency and reliable operation. Three optimized water system designs...

  10. PSNH- Municipal Smart Start Program

    Broader source: Energy.gov [DOE]

    Public Service of New Hampshire (PSNH), an electric utility, offers the Smart Start Program to Municipal customers. This program assists municipalities in reducing energy consumption and electric...

  11. ASSESSING POWER PLANT COOLING WATER INTAKE SYSTEM

    E-Print Network [OSTI]

    ASSESSING POWER PLANT COOLING WATER INTAKE SYSTEM ENTRAINMENT IMPACTS Prepared For: California be obvious that large studies like these require the coordinated work of many people. We would first like from the Duke Energy South Bay and Morro Bay power plants and the PG&E Diablo Canyon Power Plant

  12. Optimization of California's Water Supply System: Results and Insights

    E-Print Network [OSTI]

    Pasternack, Gregory B.

    headings: Optimization; California; Water supply; Water shortage. Introduction Water is scarceOptimization of California's Water Supply System: Results and Insights Marion W. Jenkins1 ; Jay R-engineering optimization model of California's water supply system. The results of this 4-year effort illustrate the value

  13. Climate Change and Water Resources in California: The Cost of Conservation versus Supply Augmentation for the East Bay Municipal Utility District

    E-Print Network [OSTI]

    Mourad, Bessma

    2009-01-01T23:59:59.000Z

    Gammon, Rovert. 2009. Sierra Water Grab. East Bay Express,www.eastbayexpress.com/news/sierra_water_grab/Content? oid=UCB: 1070. Maddaus Water Management.   Conservation

  14. Simulation Models for Improved Water Heating Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2014-01-01T23:59:59.000Z

    Difference Across the Heater and Water Flow Rate MeasuredDifference Across the Heater and Water Flow Rate Measurednew_specs/downloads/water _heaters/Water_Heater_Market_

  15. Water delivery in the Early Solar System

    E-Print Network [OSTI]

    Dvorak, Rudolf; Süli, Áron; Sándor, Zsolt; Galiazzo, Mattia; Pilat-Lohinger, Elke

    2015-01-01T23:59:59.000Z

    As part of the national scientific network 'Pathways to Habitable Worlds' the delivery of water onto terrestrial planets is a key question since water is essential for the development of life as we know it. After summarizing the state of the art we show some first results of the transport of water in the early Solar System for scattered main belt objects. Hereby we investigate the questions whether planetesimals and planetesimal fragments which have gained considerable inclination due to the strong dynamical interactions in the main belt region around 2 AU can be efficient water transporting vessels. The Hungaria asteroid group is the best example that such scenarios are realistic. Assuming that the gas giants and the terrestrial planets are already formed, we monitor the collisions of scattered small bodies containing water (in the order of a few percent) with the terrestrial planets. Thus we are able to give a first estimate concerning the respective contribution of such bodies to the actual water content i...

  16. Use of Produced Water in Recirculated Cooling Systems at Power Generating Facilities

    SciTech Connect (OSTI)

    C. McGowin; M. DiFilippo; L. Weintraub

    2006-06-30T23:59:59.000Z

    Tree ring studies indicate that, for the greater part of the last three decades, New Mexico has been relatively 'wet' compared to the long-term historical norm. However, during the last several years, New Mexico has experienced a severe drought. Some researchers are predicting a return of very dry weather over the next 30 to 40 years. Concern over the drought has spurred interest in evaluating the use of otherwise unusable saline waters to supplement current fresh water supplies for power plant operation and cooling and other uses. The U.S. Department of Energy's National Energy Technology Laboratory sponsored three related assessments of water supplies in the San Juan Basin area of the four-corner intersection of Utah, Colorado, Arizona, and New Mexico. These were (1) an assessment of using water produced with oil and gas as a supplemental supply for the San Juan Generating Station (SJGS); (2) a field evaluation of the wet-surface air cooling (WSAC) system at SJGS; and (3) the development of a ZeroNet systems analysis module and an application of the Watershed Risk Management Framework (WARMF) to evaluate a range of water shortage management plans. The study of the possible use of produced water at SJGS showed that produce water must be treated to justify its use in any reasonable quantity at SJGS. The study identified produced water volume and quality, the infrastructure needed to deliver it to SJGS, treatment requirements, and delivery and treatment economics. A number of produced water treatment alternatives that use off-the-shelf technology were evaluated along with the equipment needed for water treatment at SJGS. Wet surface air-cooling (WSAC) technology was tested at the San Juan Generating Station (SJGS) to determine its capacity to cool power plant circulating water using degraded water. WSAC is a commercial cooling technology and has been used for many years to cool and/or condense process fluids. The purpose of the pilot test was to determine if WSAC technology could cool process water at cycles of concentration considered highly scale forming for mechanical draft cooling towers. At the completion of testing, there was no visible scale on the heat transfer surfaces and cooling was sustained throughout the test period. The application of the WARMF decision framework to the San Juan Basis showed that drought and increased temperature impact water availability for all sectors (agriculture, energy, municipal, industry) and lead to critical shortages. WARMF-ZeroNet, as part of the integrated ZeroNet decision support system, offers stakeholders an integrated approach to long-term water management that balances competing needs of existing water users and economic growth under the constraints of limited supply and potential climate change.

  17. Containment system for supercritical water oxidation reactor

    DOE Patents [OSTI]

    Chastagner, P.

    1994-07-05T23:59:59.000Z

    A system is described for containment of a supercritical water oxidation reactor in the event of a rupture of the reactor. The system includes a containment for housing the reaction vessel and a communicating chamber for holding a volume of coolant, such as water. The coolant is recirculated and sprayed to entrain and cool any reactants that might have escaped from the reaction vessel. Baffles at the entrance to the chamber prevent the sprayed coolant from contacting the reaction vessel. An impact-absorbing layer is positioned between the vessel and the containment to at least partially absorb momentum of any fragments propelled by the rupturing vessel. Remote, quick-disconnecting fittings exterior to the containment, in cooperation with shut-off valves, enable the vessel to be isolated and the system safely taken off-line. Normally-closed orifices throughout the containment and chamber enable decontamination of interior surfaces when necessary. 2 figures.

  18. Containment system for supercritical water oxidation reactor

    DOE Patents [OSTI]

    Chastagner, Philippe (3134 Natalie Cir., Augusta, GA 30909-2748)

    1994-01-01T23:59:59.000Z

    A system for containment of a supercritical water oxidation reactor in the event of a rupture of the reactor. The system includes a containment for housing the reaction vessel and a communicating chamber for holding a volume of coolant, such as water. The coolant is recirculated and sprayed to entrain and cool any reactants that might have escaped from the reaction vessel. Baffles at the entrance to the chamber prevent the sprayed coolant from contacting the reaction vessel. An impact-absorbing layer is positioned between the vessel and the containment to at least partially absorb momentum of any fragments propelled by the rupturing vessel. Remote, quick-disconnecting fittings exterior to the containment, in cooperation with shut-off valves, enable the vessel to be isolated and the system safely taken off-line. Normally-closed orifices throughout the containment and chamber enable decontamination of interior surfaces when necessary.

  19. Acid mine water aeration and treatment system

    DOE Patents [OSTI]

    Ackman, Terry E. (Finleyville, PA); Place, John M. (Bethel Park, PA)

    1987-01-01T23:59:59.000Z

    An in-line system is provided for treating acid mine drainage which basically comprises the combination of a jet pump (or pumps) and a static mixer. The jet pump entrains air into the acid waste water using a Venturi effect so as to provide aeration of the waste water while further aeration is provided by the helical vanes of the static mixer. A neutralizing agent is injected into the suction chamber of the jet pump and the static mixer is formed by plural sections offset by 90 degrees.

  20. Modeling Water Resource Systems under Climate Change: IGSM-WRS

    E-Print Network [OSTI]

    Strzepek, K.

    Through the integration of a Water Resource System (WRS) component, the MIT Integrated Global System Model (IGSM) framework has been enhanced to study the effects of climate change on managed water-resource systems. ...

  1. Municipal Energy Reduction Fund

    Broader source: Energy.gov [DOE]

    In March 2010, the New Hampshire Community Development Finance Authority (CDFA) launched a revolving loan program to encourage the state’s municipal governments to invest in energy efficiency and...

  2. Critical review of water based radiant cooling system design methods

    E-Print Network [OSTI]

    Feng, Jingjuan Dove; Bauman, Fred; Schiavon, Stefano

    2014-01-01T23:59:59.000Z

    Embedded Radiant Heating and Cooling Systems, InternationalWATER BASED RADIANT COOLING SYSTEM DESIGN METHODS Jingjuan (Keywords: Radiant Cooling System, Design Approach,

  3. Army Energy and Water Reporting System Assessment

    SciTech Connect (OSTI)

    Deprez, Peggy C.; Giardinelli, Michael J.; Burke, John S.; Connell, Linda M.

    2011-09-01T23:59:59.000Z

    There are many areas of desired improvement for the Army Energy and Water Reporting System. The purpose of system is to serve as a data repository for collecting information from energy managers, which is then compiled into an annual energy report. This document summarizes reported shortcomings of the system and provides several alternative approaches for improving application usability and adding functionality. The U.S. Army has been using Army Energy and Water Reporting System (AEWRS) for many years to collect and compile energy data from installations for facilitating compliance with Federal and Department of Defense energy management program reporting requirements. In this analysis, staff from Pacific Northwest National Laboratory found that substantial opportunities exist to expand AEWRS functions to better assist the Army to effectively manage energy programs. Army leadership must decide if it wants to invest in expanding AEWRS capabilities as a web-based, enterprise-wide tool for improving the Army Energy and Water Management Program or simply maintaining a bottom-up reporting tool. This report looks at both improving system functionality from an operational perspective and increasing user-friendliness, but also as a tool for potential improvements to increase program effectiveness. The authors of this report recommend focusing on making the system easier for energy managers to input accurate data as the top priority for improving AEWRS. The next major focus of improvement would be improved reporting. The AEWRS user interface is dated and not user friendly, and a new system is recommended. While there are relatively minor improvements that could be made to the existing system to make it easier to use, significant improvements will be achieved with a user-friendly interface, new architecture, and a design that permits scalability and reliability. An expanded data set would naturally have need of additional requirements gathering and a focus on integrating with other existing data sources, thus minimizing manually entered data.

  4. A stock water solar heating system

    SciTech Connect (OSTI)

    Nydahl, J.; Carlson, B.

    1999-07-01T23:59:59.000Z

    This paper reports on the progress in the development of an inexpensive but rugged solar system to heat stock water. Insulation encased in fiber reinforced concrete is the main structural component for the collector and the partition between the unheated stock tank and the heated section. A fully wetted, drain-back collector was designed to produce a high optical efficiency and to permit its water passage to be opened for cleaning. A unique double-glazed design is used in which the inner glazing is a film with a large thermal expansion coefficient. This causes a significant drop in the stagnation temperatures since a single glazed configuration is approached at high temperatures. The collector and the partially covered insulated tank prevented freezing, and held the average water temperature at 6.4 C (44 F) during the day while the mean daily ambient temperature was {minus}5.4 C (22 F) over a nine day test.

  5. Soil Water and Temperature System (SWATS) Handbook

    SciTech Connect (OSTI)

    Bond, D

    2005-01-01T23:59:59.000Z

    The soil water and temperature system (SWATS) provides vertical profiles of soil temperature, soil-water potential, and soil moisture as a function of depth below the ground surface at hourly intervals. The temperature profiles are measured directly by in situ sensors at the Central Facility and many of the extended facilities of the SGP climate research site. The soil-water potential and soil moisture profiles are derived from measurements of soil temperature rise in response to small inputs of heat. Atmospheric scientists use the data in climate models to determine boundary conditions and to estimate the surface energy flux. The data are also useful to hydrologists, soil scientists, and agricultural scientists for determining the state of the soil.

  6. Willmar Municipal Utilities- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Willmar Municipal Utilities offer rebates on Energy Star rated appliances and air conditioners and Marathon water heaters. In addition to these rebates, WMU also offers a Load Sharing Program. ...

  7. Economic Essays on Water Resources Management of the Texas Lower Rio Grande Valley

    E-Print Network [OSTI]

    Leidner, Andrew

    2012-07-16T23:59:59.000Z

    well-being and public health. The first essay provides a description of a control model developed for the management of a municipal water supply system in the context of public health and waterborne illnesses issues. The most beneficial disease...

  8. Continuous Commissioning of a Central Chilled Water & Hot Water System

    E-Print Network [OSTI]

    Deng, S.; Turner, W. D.; Batten, T.; Liu, M.

    2000-01-01T23:59:59.000Z

    the campus loops and the building loops. Some optimization of the plant chiller 1 boiler operation is also necessary and beneficial. In general, through Continuous Commissioning, chilled water and hot water loop temperature differences will be improved...

  9. Climate Change and Water Resources in California: The Cost of Conservation versus Supply Augmentation for the East Bay Municipal Utility District

    E-Print Network [OSTI]

    Mourad, Bessma

    2009-01-01T23:59:59.000Z

    Climate change is projected to result in increasing water scarcity scenarios in California, and similar Mediterranean

  10. Conference Topic: Integrated Water Resources and Coastal Areas Management National Water Information Systems: A Tool to Support Integrated Water Resources

    E-Print Network [OSTI]

    Barthelat, Francois

    of compartmentalized data, lack of central storage, and limited access to data for decision-making in water managementConference Topic: Integrated Water Resources and Coastal Areas Management National Water Information Systems: A Tool to Support Integrated Water Resources Management in the Caribbean Marie-Claire St

  11. K West integrated water treatment system subproject safety analysis document

    SciTech Connect (OSTI)

    SEMMENS, L.S.

    1999-02-24T23:59:59.000Z

    This Accident Analysis evaluates unmitigated accident scenarios, and identifies Safety Significant and Safety Class structures, systems, and components for the K West Integrated Water Treatment System.

  12. Sustaining Sherman Island: A Water Management and Agricultural Diversification System

    E-Print Network [OSTI]

    Fischer, Richard

    2011-01-01T23:59:59.000Z

    Tank Production Systems: Aquaponics-Integrating Fish andand environmental resources. The Aquaponics Water Managementstorage zone. The aquaponics system is a bio- integrated

  13. Carbon and Water Resource Management for Water Distribution Systems

    E-Print Network [OSTI]

    Hendrickson, Thomas Peter

    2013-01-01T23:59:59.000Z

    Buckley, C. A. ; Carbon footprint analysis for increasingeffectively reduce their carbon footprint. To accomplish7 February 2013. (8) The Carbon Footprint of Water; River

  14. Water-loop heat pump systems

    SciTech Connect (OSTI)

    Eley, C.; Hydeman, M. (Eley (Charles) Associates, San Francisco, CA (United States))

    1992-12-01T23:59:59.000Z

    Water-loop heat pump (WLHP) systems are reliable, versatile, energy-efficient alternatives to conventional systems such as packaged rooftop or central chiller systems. These systems offer low installed costs, unparalleled design flexibility, and an inherent ability to recover heat in a variety of commercial and multifamily residential buildings for both new construction and retrofit markets. Southern California Edison Co. (SCE) teamed with EPRI to develop a comprehensive design guide for WLHP systems that incorporated recent research by EPRI, SCE, and others. The project team reviewed current literature, equipment data, and design guidelines from equipment manufacturers. They next discussed design and application practices with consulting engineers as well as design and building contractors. The team also ran extensive computer simulations on commercial and multifamily residential building models for Southern California, both to determine the sensitivity of energy use to WLHP system design parameters and to establish optimal design parameters. This information culminated in a comprehensive engineering guide. Volume 1 of this report, provides step-by-step technical design data for selection, application, and specification of WLHP systems. This guide emphasizes energy-efficient design principles and incorporates the findings of the computer simulations and research. For example, it recommends lowering the loop temperature in buildings dominated by internal loads. Reducing the loop temperature from 90 to 80[degrees]F provides a 7--10% savings in the total system energy in Southern California climate areas. Other recommendations include (1) installing a cooling tower with a propeller fan, which uses one fourth to one third of the energy of a cooling tower with a centrifugal fan; and (2) incorporating variable-speed pumps in conjunction with two-position valves in the heat pumps to reduce the system pump energy use by up to 50%.

  15. POOL WATER TREATMENT AND COOLING SYSTEM DESCRIPTION DOCUMENT

    SciTech Connect (OSTI)

    V. King

    2000-06-19T23:59:59.000Z

    The Pool Water Treatment and Cooling System is located in the Waste Handling Building (WHB), and is comprised of various process subsystems designed to support waste handling operations. This system maintains the pool water temperature within an acceptable range, maintains water quality standards that support remote underwater operations and prevent corrosion, detects leakage from the pool liner, provides the capability to remove debris from the pool, controls the pool water level, and helps limit radiological exposure to personnel. The pool structure and liner, pool lighting, and the fuel staging racks in the pool are not within the scope of the Pool Water Treatment and Cooling System. Pool water temperature control is accomplished by circulating the pool water through heat exchangers. Adequate circulation and mixing of the pool water is provided to prevent localized thermal hotspots in the pool. Treatment of the pool water is accomplished by a water treatment system that circulates the pool water through filters, and ion exchange units. These water treatment units remove radioactive and non-radioactive particulate and dissolved solids from the water, thereby providing the water clarity needed to conduct waste handling operations. The system also controls pool water chemistry to prevent advanced corrosion of the pool liner, pool components, and fuel assemblies. Removal of radioactivity from the pool water contributes to the project ALARA (as low as is reasonably achievable) goals. A leak detection system is provided to detect and alarm leaks through the pool liner. The pool level control system monitors the water level to ensure that the minimum water level required for adequate radiological shielding is maintained. Through interface with a demineralized water system, adequate makeup is provided to compensate for loss of water inventory through evaporation and waste handling operations. Interface with the Site Radiological Monitoring System provides continuous radiological monitoring of the pool water. The Pool Water Treatment and Cooling System interfaces with the Waste Handling Building System, Site-Generated Radiological Waste Handling System, Site Radiological Monitoring System, Waste Handling Building Electrical System, Site Water System, and the Monitored Geologic Repository Operations Monitoring and Control System.

  16. Design package for solar domestic hot water system

    SciTech Connect (OSTI)

    None

    1980-09-01T23:59:59.000Z

    Information used to evaluate the initial design of the Elcam, Inc., Solar Domestic Hot Water System is presented. Included are such items as the system performance specification, detailed design drawings and other information. Elcam, Inc., has developed two solar heated prototype hot water systems and two heat exchangers. The hot water systems consist of the following subsystems: collector, storage, control, transport, auxiliary energy, and government-furnished Site Data Acquisition. The two systems are installed at Tempe, Arizona, and San Diego, California.

  17. Simulation Models for Improved Water Heating Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2014-01-01T23:59:59.000Z

    and Simulation of a Smart Water Heater. ” In Workshop inFreezers, Furnaces, Water Heaters, Room and Central AirNovember. ADL. 1982b. Water Heater Computer Model User’s

  18. CC Retrofits and Optimal Controls for Hot Water Systems

    E-Print Network [OSTI]

    Wu, L.; Liu, M.; Wang, G.

    2007-01-01T23:59:59.000Z

    Continuous Commissioning (CC) technologies, three old boilers (13.39 MMBH each) were replaced by three new boilers (1.675 MMBH each) and hot water pumps. Optimal controls for the hot water systems included optimal hot water temperature reset, hot water pump...

  19. Charles J. Vrsmarty & the UNH Water Systems Analysis Group

    E-Print Network [OSTI]

    Slatton, Clint

    .1 billion people lack clean drinking water 2.6 billion people lack basic sanitationCharles J. Vörösmarty & the UNH Water Systems Analysis Group Fall Water Institute Seminar Series Corridor #12;Goals for This Discussion · Describe chief forces shaping the contemporary and future water

  20. Concord Municipal Light Plant- Solar Photovoltaic Rebate Program

    Broader source: Energy.gov [DOE]

    Concord Municipal Light Plant (CMLP) offers rebates to customers who install solar photovoltaic (PV) systems that are designed to offset the customer's electrical needs. Systems must be owned by...

  1. Enhanced monitor system for water protection

    DOE Patents [OSTI]

    Hill, David E. (Knoxville, TN) [Knoxville, TN; Rodriquez, Jr., Miguel [Oak Ridge, TN; Greenbaum, Elias (Knoxville, TN) [Knoxville, TN

    2009-09-22T23:59:59.000Z

    An automatic, self-contained device for detecting toxic agents in a water supply includes an analyzer for detecting at least one toxic agent in a water sample, introducing a means for introducing a water sample into the analyzer and discharging the water sample from the analyzer, holding means for holding a water sample for a pre-selected period of time before the water sample is introduced into the analyzer, and an electronics package that analyzes raw data from the analyzer and emits a signal indicating the presence of at least one toxic agent in the water sample.

  2. Installation package for a Sunspot Cascade Solar Water Heating System

    SciTech Connect (OSTI)

    None

    1980-09-01T23:59:59.000Z

    Elcam, Incorporated of Santa Barbara, California, has developed two solar water heating systems. The systems have been installed at Tempe, Arizona and San Diego, California. The systems consist of the following: collector, collector-tank water loop, solar tank, conventional tank and controls. General guidelines are provided which may be utilized in development of detailed instalation plans and specifications. In addition, it provides instruction on operation, maintenance and installation of solar hot water systems.

  3. Building America Webinar: Central Multifamily Water Heating Systems

    Broader source: Energy.gov [DOE]

    Hosted by DOE's Building America program, this webinar will focus on the effective use of central heat pump water heaters (HPWHs) and control systems to reduce the energy use in hot water distribution.

  4. Building America Webinar: Central Multifamily Water Heating Systems...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    to 4:30PM EST This free webinar will focus on the effective use of central heat pump water heaters (HPWHs) and control systems to reduce the energy use in hot water...

  5. Feasibility and design of blast mitigation systems for naval applications using water mist fire suppression systems

    E-Print Network [OSTI]

    Kitchenka, Julie A

    2004-01-01T23:59:59.000Z

    The recent trend of using fine water mist systems to replace the legacy HALON- 1301 fire suppression systems warrants further study into other applications of the water mist systems. Preliminary research and investigation ...

  6. Homeland Security Challenges Facing Small Water Systems in Texas 

    E-Print Network [OSTI]

    Dozier, Monty; Theodori, Gene L.; Jensen, Ricard

    2007-05-31T23:59:59.000Z

    and Extension Specialist; and Ric Jensen, Assistant Research Scientist, Texas Water Resources Institute; The Texas A&M University System Water systems of all sizes, including small systems, may be vulner- able to man-made and natural threats that can...

  7. STATE OF CALIFORNIA SOLAR DOMESTIC HOT WATER SYSTEMS (SDHW)

    E-Print Network [OSTI]

    attached CEC F-Chart) # of Collectors in System Collector Size Solar Tank Volume (gallons) §150(j)1B piping shall be insulated. §150(j)4: Solar water-heating system and/or/collectors are certifiedSTATE OF CALIFORNIA SOLAR DOMESTIC HOT WATER SYSTEMS (SDHW) CEC- CF-6R-MECH-02 (Revised 08

  8. El Dorado County Water Systems Energy Generation Project

    E-Print Network [OSTI]

    water systems within the El Dorado Irrigation District and the Georgetown Divide Public UtilityEl Dorado County Water Systems Energy Generation Project RENEWABLE ENERGY RESEARCH www systems, there is significant room for improvement in energy management, efficiency, and reducing demand

  9. Montana Ground Water Pollution Control System Permit Application...

    Open Energy Info (EERE)

    search OpenEI Reference LibraryAdd to library Web Site: Montana Ground Water Pollution Control System Permit Application Forms Webpage Abstract Provides a list of permit...

  10. Sensor Networks for Monitoring and Control of Water Distribution Systems

    E-Print Network [OSTI]

    Whittle, Andrew

    Water distribution systems present a significant challenge for structural monitoring. They comprise a complex network of pipelines buried underground that are relatively inaccessible. Maintaining the integrity of these ...

  11. Building America Webinar: Central Multifamily Water Heating Systems

    Broader source: Energy.gov [DOE]

    This U.S. Department of Energy Building America webinar, Central Multifamily Water Heating Systems, will take place on January 21, 2015.

  12. VAPOR + LIQUID EQUILIBRIUM OF WATER, CARBON DIOXIDE, AND THE BINARY SYSTEM WATER + CARBON DIOXIDE FROM

    E-Print Network [OSTI]

    ) and their binary mixtures (between 348 and 393 K). The properties of supercritical carbon dioxide were determinedVAPOR + LIQUID EQUILIBRIUM OF WATER, CARBON DIOXIDE, AND THE BINARY SYSTEM WATER + CARBON DIOXIDE the vapor-liquid equilibrium of water (between 323 and 573 K), carbon dioxide (between 230 and 290 K

  13. Reducing Disinfection By-Products in Small Drinking Water Systems

    E-Print Network [OSTI]

    not decrease the residual TOC by 0.3 mg/L. #12;Guidelines: Coagulant dosages for water supplies where NOMReducing Disinfection By-Products in Small Drinking Water Systems by M. Robin Collins, James P. Malley, Jr, & Ethan Brooke Water Treatment Technology Assistance Center Department of Civil Engineering

  14. Design of Hard Water Stable Emulsifier Systems for Petroleum-

    E-Print Network [OSTI]

    Clarens, Andres

    Design of Hard Water Stable Emulsifier Systems for Petroleum- and Bio-based Semi for petroleum and bio-based MWFs that improve fluid lifetime by providing emulsion stability under hard water. The newly developed petroleum and bio-based formulations with improved hard water stability are competitive

  15. Seismic Fragility of the LANL Fire Water Distribution System

    SciTech Connect (OSTI)

    Greg Mertz

    2007-03-30T23:59:59.000Z

    The purpose of this report is to present the results of a site-wide system fragility assessment. This assessment focuses solely on the performance of the water distribution systems that supply Chemical and Metallurgy Research (CMR), Weapons Engineering and Tritium Facility (WETF), Radioactive Liquid Waste Treatment Facility (RLWTF), Waste Characterization, Reduction, Repackaging Facility (WCRRF), and Transuranic Waste Inspectable Storage Project (TWISP). The analysis methodology is based on the American Lifelines Alliance seismic fragility formulations for water systems. System fragilities are convolved with the 1995 LANL seismic hazards to develop failure frequencies. Acceptance is determined by comparing the failure frequencies to the DOE-1020 Performance Goals. This study concludes that: (1) If a significant number of existing isolation valves in the water distribution system are closed to dedicate the entire water system to fighting fires in specific nuclear facilities; (2) Then, the water distribution systems for WETF, RLWTF, WCRRF, and TWISP meet the PC-2 performance goal and the water distribution system for CMR is capable of surviving a 0.06g earthquake. A parametric study of the WETF water distribution system demonstrates that: (1) If a significant number of valves in the water distribution system are NOT closed to dedicate the entire water system to fighting fires in WETF; (2) Then, the water distribution system for WETF has an annual probability of failure on the order of 4 x 10{sup -3} that does not meet the PC-2 performance goal. Similar conclusions are expected for CMR, RLWTF, WCRRF, and TWISP. It is important to note that some of the assumptions made in deriving the results should be verified by personnel in the safety-basis office and may need to be incorporated in technical surveillance requirements in the existing authorization basis documentation if credit for availability of fire protection water is taken at the PC-2 level earthquake levels. Assumptions are presented in Section 2.2 of this report.

  16. Rig-site system allows water reuse, cuts cleanup costs

    SciTech Connect (OSTI)

    Neidhardt, D.

    1985-03-04T23:59:59.000Z

    A new well-site treatment system is described which extends the use of solids control equipment to help solve the common drilling problems of water supply and/or wastewater disposal. The new closed-loop system combines water treatment with more conventional solids handling to continuously create clean water. The results include: re-use of water for rig cleaning, mud, and even cement makeup with no need to eject liquid to the environment; greatly reduced water-input requirements; and division of the conventional wastewater pit into an active treatment operations pit and an overflow reserve pit for emergency storage.

  17. Taunton Municipal Lighting Plant- Residential PV Rebate Program

    Broader source: Energy.gov [DOE]

    Customers of Taunton Municipal Lighting Plant (TMLP) may be eligible for $2.00/watt rebate on solar photovoltaic (PV) installations. The minimum system size eligible for this rebate is 1 kilowatt ...

  18. River Falls Municipal Utilities- Renewable Energy Finance Program

    Broader source: Energy.gov [DOE]

    River Falls Municipal Utilities (RFMU) offers loans of $2,500 - $50,000 to its residential customers for the installation of photovoltaic (PV), solar thermal, geothermal, wind electric systems. The...

  19. Concord Municipal Light Plant- Commercial Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Concord Municipal Light Plant (CMLP) offers rebates to commercial customers for a variety of appliances, ETS heating systems, general lighting upgrades, CFL bulbs, and exit sign retrofit kits. A...

  20. Vulnerability assessment of water supply systems for insufficient fire flows

    E-Print Network [OSTI]

    Kanta, Lufthansa Rahman

    2009-05-15T23:59:59.000Z

    supply systems are vulnerable to many forms of terrorist acts, most of the vulnerability analysis studies on these systems have been for chemical and biological threats. Because of the interdependency of water supply infrastructure and emergency fire...

  1. Improving Heating System Operations Using Water Re-Circulation

    E-Print Network [OSTI]

    Li, F.; Han, J.

    2006-01-01T23:59:59.000Z

    In order to solve the imbalance problem of a heating system, brought about by consumer demand and regulation, and save the electricity energy consumed by a circulation pump, a water mixing and pressure difference control heating system is proposed...

  2. Minimizing Energy Consumption in a Water Distribution System: A Systems Modeling Approach

    E-Print Network [OSTI]

    Johnston, John

    2011-08-08T23:59:59.000Z

    In a water distribution system from groundwater supply, the bulk of energy consumption is expended at pump stations. These pumps pressurize the water and transport it from the aquifer to the distribution system and to elevated storage tanks. Each...

  3. Fourteenth Service Water System Reliability Improvement Seminar Proceedings

    SciTech Connect (OSTI)

    None

    2002-06-01T23:59:59.000Z

    This report contains information presented at the Fourteenth Service Water System Reliability Improvement (SWSRI) Seminar held June 24-25, 2002, in San Diego, California. The bi-annual seminar--sponsored by EPRI--provided an opportunity for participants to exchange technical information and experiences regarding the monitoring, repair, and replacement of service water system components.

  4. Analysis Model for Domestic Hot Water Distribution Systems: Preprint

    SciTech Connect (OSTI)

    Maguire, J.; Krarti, M.; Fang, X.

    2011-11-01T23:59:59.000Z

    A thermal model was developed to estimate the energy losses from prototypical domestic hot water (DHW) distribution systems for homes. The developed model, using the TRNSYS simulation software, allows researchers and designers to better evaluate the performance of hot water distribution systems in homes. Modeling results were compared with past experimental study results and showed good agreement.

  5. Evaporative system for water and beverage refrigeration in hot countries

    E-Print Network [OSTI]

    Evaporative system for water and beverage refrigeration in hot countries A Saleh1 and MA Al-Nimr2 1 Abstract: The present study proposes an evaporative refrigerating system used to keep water or other are found to be consistent with the available literature data. Keywords: evaporative refrigeration, heat

  6. Performance Monitoring of Residential Hot Water Distribution Systems

    SciTech Connect (OSTI)

    Liao, Anna; Lanzisera, Steven; Lutz, Jim; Fitting, Christian; Kloss, Margarita; Stiles, Christopher

    2014-08-11T23:59:59.000Z

    Current water distribution systems are designed such that users need to run the water for some time to achieve the desired temperature, wasting energy and water in the process. We developed a wireless sensor network for large-scale, long time-series monitoring of residential water end use. Our system consists of flow meters connected to wireless motes transmitting data to a central manager mote, which in turn posts data to our server via the internet. This project also demonstrates a reliable and flexible data collection system that could be configured for various other forms of end use metering in buildings. The purpose of this study was to determine water and energy use and waste in hot water distribution systems in California residences. We installed meters at every end use point and the water heater in 20 homes and collected 1s flow and temperature data over an 8 month period. For a typical shower and dishwasher events, approximately half the energy is wasted. This relatively low efficiency highlights the importance of further examining the energy and water waste in hot water distribution systems.

  7. Multiscale modeling of clay-water systems

    E-Print Network [OSTI]

    Ebrahimi, Davoud

    2014-01-01T23:59:59.000Z

    The engineering properties of soils are highly affected by clay content and clay-water interactions. However, existing macro-scale continuum models have no length scale to describe the evolution of the clay microstructure ...

  8. Predicting on-site environmental impacts of municipal engineering works

    SciTech Connect (OSTI)

    Gangolells, Marta, E-mail: marta.gangolells@upc.edu; Casals, Miquel, E-mail: miquel.casals@upc.edu; Forcada, Núria, E-mail: nuria.forcada@upc.edu; Macarulla, Marcel, E-mail: marcel.macarulla@upc.edu

    2014-01-15T23:59:59.000Z

    The research findings fill a gap in the body of knowledge by presenting an effective way to evaluate the significance of on-site environmental impacts of municipal engineering works prior to the construction stage. First, 42 on-site environmental impacts of municipal engineering works were identified by means of a process-oriented approach. Then, 46 indicators and their corresponding significance limits were determined on the basis of a statistical analysis of 25 new-build and remodelling municipal engineering projects. In order to ensure the objectivity of the assessment process, direct and indirect indicators were always based on quantitative data from the municipal engineering project documents. Finally, two case studies were analysed and found to illustrate the practical use of the proposed model. The model highlights the significant environmental impacts of a particular municipal engineering project prior to the construction stage. Consequently, preventive actions can be planned and implemented during on-site activities. The results of the model also allow a comparison of proposed municipal engineering projects and alternatives with respect to the overall on-site environmental impact and the absolute importance of a particular environmental aspect. These findings are useful within the framework of the environmental impact assessment process, as they help to improve the identification and evaluation of on-site environmental aspects of municipal engineering works. The findings may also be of use to construction companies that are willing to implement an environmental management system or simply wish to improve on-site environmental performance in municipal engineering projects. -- Highlights: • We present a model to predict the environmental impacts of municipal engineering works. • It highlights significant on-site environmental impacts prior to the construction stage. • Findings are useful within the environmental impact assessment process. • They also help contractors to implement environmental management systems.

  9. Illinois Municipal Electric Agency- Electric Efficiency Program

    Broader source: Energy.gov [DOE]

    The Illinois Municipal Electric Agency (IMEA) offers rebates to member municipal utilities* (those who purchase wholesale electric service from IMEA) and retail customers for energy efficiency...

  10. Essays on Municipal Public Finance in Brazil

    E-Print Network [OSTI]

    Gardner, Rachel Elizabeth

    2013-01-01T23:59:59.000Z

    on Municipal Public Finance in Brazil By Rachel Elizabethon Municipal Public Finance in Brazil by Rachel Elizabethlocal public finance in Brazil, with a focus on how federal

  11. Municipal Energy Plan Program (Ontario, Canada)

    Broader source: Energy.gov [DOE]

    Ontario is supporting local energy planning by introducing the Municipal Energy Plan (MEP) program. The MEP program is designed to help municipalities better understand their local energy needs ...

  12. Massachusetts Municipal Commercial Industrial Incentive Program

    Broader source: Energy.gov [DOE]

    Certain municipal utilities in Massachusetts, in cooperation with Massachusetts Municipal Wholesale Electric Company ([http://www.mmwec.org/ MMWEC]), have begun offering energy efficiency...

  13. Ceramic coating system or water oxidation environments

    DOE Patents [OSTI]

    Hong, Glenn T. (Tewksbury, MA)

    1996-01-01T23:59:59.000Z

    A process for water oxidation of combustible materials in which during at least a part of the oxidation corrosive material is present and makes contact with at least a portion of the apparatus over a contact area on the apparatus. At least a portion of the contact surface area comprises titanium dioxide coated onto a titanium metal substrate. Such ceramic composites have been found to be highly resistant to environments encountered in the process of supercritical water oxidation. Such environments typically contain greater than 50 mole percent water, together with oxygen, carbon dioxide, and a wide range of acids, bases, and salts. Pressures are typically about 27.5 to about 1000 bar while temperatures range as high as 700.degree. C. The ceramic composites are also resistant to degradation mechanisms caused by thermal stresses.

  14. Milli-Q Reference Water Purification System

    E-Print Network [OSTI]

    Woodall, Jerry M.

    , they must do so at a faster pace, while meeting increasing standards and often operating in laboratories water quality Large digital & graphic screen with detailed procedures for full on line support Inside graphics help you perform specific tasks such as maintenance. From the same screen, you can even print

  15. Hamerschlag Hall Green Roof Project Water Monitoring System

    E-Print Network [OSTI]

    Andrews, Peter B.

    1 Hamerschlag Hall Green Roof Project Water Monitoring System Plans and Specifications Created By: David Carothers Date: 2/17/05 #12;2 Hamerschlag Hall Green Roof Project Date: 2/14/05 Created By: David and the flumes shall be water tight. (Figures 1&2) · The connection between the flume and the green roof membrane

  16. New computerized system saves water and money By Kate Weidaw

    E-Print Network [OSTI]

    Johnston, Daniel

    New computerized system saves water and money By Kate Weidaw Updated: Thursday, October 10, 2013 on the University of Texas campus in Austin and the savings is counted in more than just gallons of water on the savings are just coming in and the changes have resulted in a savings of nearly one million dollars a year

  17. Analyzing risk and uncertainty for improving water distribution system security from malevolent water supply contamination events

    E-Print Network [OSTI]

    Torres, Jacob Manuel

    2009-05-15T23:59:59.000Z

    Previous efforts to apply risk analysis for water distribution systems (WDS) have not typically included explicit hydraulic simulations in their methodologies. A risk classification scheme is here employed for identifying vulnerable WDS components...

  18. Utilization of municipal wastewater for cooling in thermoelectric power plants

    SciTech Connect (OSTI)

    Safari, Iman; Walker, Michael E.; Hsieh, Ming-Kai; Dzombak, David A.; Liu, Wenshi; Vidic, Radisav D.; Miller, David C.; Abbasian, Javad

    2013-09-01T23:59:59.000Z

    A process simulation model has been developed using Aspen Plus(R) with the OLI (OLI System, Inc.) water chemistry model to predict water quality in the recirculating cooling loop utilizing secondary- and tertiary-treated municipal wastewater as the source of makeup water. Simulation results were compared with pilot-scale experimental data on makeup water alkalinity, loop pH, and ammonia evaporation. The effects of various parameters including makeup water quality, salt formation, NH{sub 3} and CO{sub 2} evaporation mass transfer coefficients, heat load, and operating temperatures were investigated. The results indicate that, although the simulation model can capture the general trends in the loop pH, experimental data on the rates of salt precipitation in the system are needed for more accurate prediction of the loop pH. It was also found that stripping of ammonia and carbon dioxide in the cooling tower can influence the cooling loop pH significantly. The effects of the NH{sub 3} mass transfer coefficient on cooling loop pH appear to be more significant at lower values (e.g., k{sub NH3}< 4×10{sup -3} m/s) when the makeup water alkalinity is low (e.g., <90 mg/L as CaCO{sub 3}). The effect of the CO{sub 2} mass transfer coefficient was found to be significant only at lower alkalinity values (e.g., k{sub CO2}<4×10{{sup -6} m/s).

  19. Effect of Water Education on Reducing Residential Consumption in San Antonio, Texas

    E-Print Network [OSTI]

    Rice, Jeremy Joseph

    2010-10-12T23:59:59.000Z

    cities in the southwest found that nearly 60% percent of water was used outdoors.(Mayer 1999). Municipal water conservation programs focus on reducing residential, commercial and industrial consumption. Residential water conservation relies on five... of week limitations; (4) rebate programs encouraging a change of landscape material to drought tolerant native landscapes and (5) water pricing. San Antonio has employed all five conservation strategies. Currently, the San Antonio Water System (SAWS...

  20. Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems

    SciTech Connect (OSTI)

    Rudd, A.; Ueno, K.; Bergey, D.; Osser, R.

    2012-07-01T23:59:59.000Z

    The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

  1. Stealthy Deception Attacks on Water SCADA Systems Saurabh Amin

    E-Print Network [OSTI]

    day irrigation canal systems. This type of monitoring and control infrastructure is also commonStealthy Deception Attacks on Water SCADA Systems Saurabh Amin Department of CEE UC Berkeley, CA the vulnerabilities of Supervisory Control and Data Acquisition (SCADA) systems which mon- itor and control the modern

  2. Boiler Upgrades and Decentralizing Steam Systems Save Water and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Steam Systems Save Water and Energy at Naval Air Station Oceana Case study details Naval Air Station Oceana findings that its heating needs could be met more efficiently by...

  3. Strategic indicators for characterization of water system infrastructure and management

    E-Print Network [OSTI]

    Garvin, Michael J. (Michael Joseph)

    2001-01-01T23:59:59.000Z

    Shifts in the US water industry are characteristic of the flux found across all infrastructure sectors. Economic, environmental, market, regulatory and systemic forces are pushing the industry toward a different future ...

  4. Homeland Security Challenges Facing Small Water Systems in Texas

    E-Print Network [OSTI]

    Dozier, Monty; Theodori, Gene L.; Jensen, Ricard

    2007-05-31T23:59:59.000Z

    across Texas A&M are now developing graduate classes on such areas as government programs related to homeland security, haz- ard mitigation, cybersecurity, public health and critical infrastructure protection related to water and wastewater systems...

  5. Water Rights Analysis Package (WRAP) Modeling System Reference Manual

    E-Print Network [OSTI]

    Wurbs, Ralph A.

    . Basin-wide impacts of water resources development projects and management strategies may be evaluated. The software package is generalized for application to any river/reservoir/use system, with input files being developed for the particular river basin...

  6. EA-1093: Surface Water Drainage System, Golden, Colorado

    Broader source: Energy.gov [DOE]

    This EA evaluates the environmental impacts of the proposal to correct deficiencies in, and then to maintain, the surface water drainage system serving the U.S. Department of Energy's Rocky Flats...

  7. auxiliary water systems: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Topic Index 1 Discussions on Disposal Forms of Auxiliary Heat Source in Surface Water Heat Pump System Texas A&M University - TxSpace Summary: This paper presents two common...

  8. Water Distribution and Wastewater Systems Operators (North Dakota)

    Broader source: Energy.gov [DOE]

    All public water supply and wastewater disposal systems are subject to classification and regulation by the State of North Dakota, and must obtain certification from the State Department of Health.

  9. Waverly Municipal Elec Utility | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty Edit withTianlin BaxinUmweltVillageGraph HomeWaranaWater PowerWaverly Municipal Elec

  10. Nationwide water availability data for energy-water modeling.

    SciTech Connect (OSTI)

    Tidwell, Vincent Carroll; Zemlick, Katie M.; Klise, Geoffrey Taylor

    2013-11-01T23:59:59.000Z

    The purpose of this effort is to explore where the availability of water could be a limiting factor in the siting of new electric power generation. To support this analysis, water availability is mapped at the county level for the conterminous United States (3109 counties). Five water sources are individually considered, including unappropriated surface water, unappropriated groundwater, appropriated water (western U.S. only), municipal wastewater and brackish groundwater. Also mapped is projected growth in non-thermoelectric consumptive water demand to 2035. Finally, the water availability metrics are accompanied by estimated costs associated with utilizing that particular supply of water. Ultimately these data sets are being developed for use in the National Renewable Energy Laboratories' (NREL) Regional Energy Deployment System (ReEDS) model, designed to investigate the likely deployment of new energy installations in the U.S., subject to a number of constraints, particularly water.

  11. Water oxidation reaction in natural and artificial photosynthetic systems

    SciTech Connect (OSTI)

    Yano, Junko; Yachandra, Vittal [Physical Biosciences Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd., Berkeley, CA 94720 (United States)

    2013-12-10T23:59:59.000Z

    Understanding the structure and mechanism of water oxidation catalysts is an essential component for developing artificial photosynthetic devices. In the natural water oxidation catalyst, the geometric and electronic structure of its inorganic core, the Mn{sub 4}CaO{sub 5} cluster, has been studied by spectroscopic and diffraction measurements. In inorganic systems, metal oxides seem to be good candidates for water oxidation catalysts. Understanding the reaction mechanism in both natural and oxide-based catalysts will helpin further developing efficient and robust water oxidation catalysts.

  12. Energy utilization: municipal waste incineration. Final report

    SciTech Connect (OSTI)

    LaBeck, M.F.

    1981-03-27T23:59:59.000Z

    An assessment is made of the technical and economical feasibility of converting municipal waste into useful and useable energy. The concept presented involves retrofitting an existing municipal incinerator with the systems and equipment necessary to produce process steam and electric power. The concept is economically attractive since the cost of necessary waste heat recovery equipment is usually a comparatively small percentage of the cost of the original incinerator installation. Technical data obtained from presently operating incinerators designed specifically for generating energy, documents the technical feasibility and stipulates certain design constraints. The investigation includes a cost summary; description of process and facilities; conceptual design; economic analysis; derivation of costs; itemized estimated costs; design and construction schedule; and some drawings.

  13. Water augmented indirectly-fired gas turbine systems and method

    DOE Patents [OSTI]

    Bechtel, Thomas F. (Lebanon, PA); Parsons, Jr., Edward J. (Morgantown, WV)

    1992-01-01T23:59:59.000Z

    An indirectly-fired gas turbine system utilizing water augmentation for increasing the net efficiency and power output of the system is described. Water injected into the compressor discharge stream evaporatively cools the air to provide a higher driving temperature difference across a high temperature air heater which is used to indirectly heat the water-containing air to a turbine inlet temperature of greater than about 1,000.degree. C. By providing a lower air heater hot side outlet temperature, heat rejection in the air heater is reduced to increase the heat recovery in the air heater and thereby increase the overall cycle efficiency.

  14. Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

    SciTech Connect (OSTI)

    Schoenbauer, B.; Bohac, D.; Huelman, P.; Olson, R.; Hewitt, M.

    2012-10-01T23:59:59.000Z

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  15. WATER DATA MANAGEMENT SYSTEMS INTEGRATIONS WITH MODELS

    E-Print Network [OSTI]

    Rhode Island, University of

    Acquisition (SCADA) system that can control operations in treatment plants, as well as continuously check and SCADA interfaces for even more integrated analyses, which is important since many suppliers are implementing SCADA systems. However, only about thirty-five (35) percent of the suppliers have a functioning

  16. The water megamaser in the merger system Arp299

    E-Print Network [OSTI]

    A. Tarchi; P. Castangia; C. Henkel; K. M. Menten

    2006-10-30T23:59:59.000Z

    We present preliminary results of an interferometric study of the water megamaser in the merger system Arp299. This system is composed of two main sources: IC694 and NGC3690. There is clear evidence that most of the water maser emission is associated with the nucleus of the latter, confirming the presence of an optically obscured AGN as previously suggested by X-ray observations. Furthermore, emission arises from the inner regions of IC694, where an OH megamaser is also present. The velocity of the water maser line is blueshifted w.r.t. the optically determined systemic velocity and is consistent with that of the OH megamaser line. This finding might then indicate that both masers are associated with the same (expanding) structure and that, for the first time, strong 22 GHz water and 1.67 GHz OH maser emission has been found to coexist.

  17. New mud system produces solids-free, reusable water

    SciTech Connect (OSTI)

    NONE

    1996-02-01T23:59:59.000Z

    The Corpus Christi, Texas, based Cameron Equipment Co., Inc., has developed a closed-loop mud treating system that removes solids from water-based systems and leaves the separated fluid clean and chemical free enough to be re-used directly on the rig. The system has been successfully applied by a Gulf of Mexico operator in areas where zero discharge is required. The alternative mud conditions program offered by the developers is called the Cameron Fluid Recycling System. Designed for closed-loop water-based fluids, the system is a new method of removing solids from normally discharged fluids such as drilling mud, waste and wash water, or any other water-based fluid that contains undesirable solids. The patented method efficiently produces end products that are (1) dry solids; and (2) essentially 100% solids-free fluid that can be re-used in the same mud system. All excess drilling mud, and all wash water that would normally go to the reserve pit or a cuttings barge are collected in a tank. Recycled fluid is compatible with the mud system fluid, no harmful chemicals are used, and pH is not altered.

  18. LANSCE Drift Tube Linac Water Control System Refurbishment

    SciTech Connect (OSTI)

    Marroquin, Pilar S. [Los Alamos National Laboratory

    2011-01-01T23:59:59.000Z

    There are several refurbishment projects underway at the Los Alamos National Laboratory LANSCE linear accelerator. Systems involved are: RF, water cooling, networks, diagnostics, timing, controls, etc. The Drift Tube Linac (DTL) portion of the accelerator consists of four DTL tanks, each with three independent water control systems. The systems are about 40 years old, use outdated and non-replaceable equipment and NIM bin control modules, are beyond their design life and provide unstable temperature control. Insufficient instrumentation and documentation further complicate efforts at maintaining system performance. Detailed design of the replacement cooling systems is currently in progress. Previous design experience on the SNS accelerator water cooling systems will be leveraged, see the SNS DTL FDR. Plans call for replacement of water piping, manifolds, pumps, valves, mix tanks, instrumentation (flow, pressure and temperature) and control system hardware and software. This presentation will focus on the control system design with specific attention on planned use of the National Instruments Compact RIO platform with the Experimental Physics and Industrial Control system (EPICS) software toolkit.

  19. Energy Conservation in Process Chilled Water Systems

    E-Print Network [OSTI]

    Ambs, L. L.; DiBella, R. A.

    The energy consumption of the chiller and cooling tower in a process cooling application was analyzed using the TRNSYS computer code. The basic system included a constant speed centrifugal chiller and an induced-draft, counterflow cooling tower...

  20. Reduction of Vinyl Chloride in Metallic Iron-Water Systems

    E-Print Network [OSTI]

    Deng, Baolin

    Reduction of Vinyl Chloride in Metallic Iron-Water Systems B A O L I N D E N G * Department to groundwater and soil contamination. In particular, VC can be produced as an intermediate in the reductive- lenging. Traditional "pump-and-treat" treatment systems have proven to be costly and ineffective in many

  1. A multilayer shallow water system for polydisperse sedimentation

    E-Print Network [OSTI]

    Bürger, Raimund

    functions. The resulting multilayer sedimentation-flow model can be written as a hyperbolic systemA multilayer shallow water system for polydisperse sedimentation E.D. Fern´andez-Nieto , E.H. Kon of a fluid containing one disperse substance consisting of small particles that belong to different species

  2. Detection of the Water Reservoir in a Forming Planetary System

    E-Print Network [OSTI]

    Hogerheijde, Michiel R; Brinch, Christian; Cleeves, L Ilsedore; Fogel, Jeffrey K J; Blake, Geoffrey A; Dominik, Carsten; Lis, Dariusz C; Melnick, Gary; Neufeld, David; Panic, Olja; Pearson, John C; Kristensen, Lars; Yildiz, Umut A; van Dishoeck, Ewine F

    2011-01-01T23:59:59.000Z

    Icy bodies may have delivered the oceans to the early Earth, yet little is known about water in the ice-dominated regions of extra-solar planet-forming disks. The Heterodyne Instrument for the Far-Infrared on-board the Herschel Space Observatory has detected emission from both spin isomers of cold water vapor from the disk around the young star TW Hydrae. This water vapor likely originates from ice-coated solids near the disk surface hinting at a water ice reservoir equivalent to several thousand Earth Oceans in mass. The water's ortho-to-para ratio falls well below that of Solar System comets, suggesting that comets contain heterogeneous ice mixtures collected across the entire solar nebula during the early stages of planetary birth.

  3. Solar space and water heating system installed at Charlottesville, Virginia

    SciTech Connect (OSTI)

    Greer, Charles R.

    1980-09-01T23:59:59.000Z

    The solar energy system located at David C. Wilson Neuropsychiatric Hospital, Charlottesville, Virginia, consists of 88 single glazed, Sunworks Solector copper base plate collector modules; hot water coils in the hot air ducts; a domestic hot water (DHW) preheat tank; a 3,000 gallon concrete urethane-insulated storage tank and other miscellaneous components. This report includes extracts from the site files, specifications, drawings, installation, operation and maintenance instructions.

  4. Design of a high temperature hot water central heating system

    SciTech Connect (OSTI)

    Beaumont, E.L.; Johnson, R.C.; Weaver, J.M.

    1981-11-01T23:59:59.000Z

    The paper reviews the conceptual design of a central heating system at Los Alamos Scientific Laboratory. The resource considered for this heating system design was hot dry rock geothermal energy. Design criteria were developed to ensure reliability of energy supply, to provide flexibility for adaptation to multiple energy resources, to make optimum use of existing equipment and to minimize reinvestment cost. A variable temperature peaking high temperature water system was selected for this purpose.

  5. Design manual for high temperature hot water and steam systems

    SciTech Connect (OSTI)

    Cofield, R.E. Jr.

    1984-01-01T23:59:59.000Z

    The author presents aspects of high temperature hot water and steam generating systems. It covers all the calculations that must be made for sizing and then selecting the equipment that will make up an energy system. The author provides essential information on loan analysis, types of fuel, storage requirements, handling facilities, waste disposal, HVAC needs, and back-up systems. Also included are the calculations needed for determining the size of compressors, air pollution devices, fans, filters, and other supplementary equipment.

  6. Hot Water Distribution System Model Enhancements

    SciTech Connect (OSTI)

    Hoeschele, M.; Weitzel, E.

    2012-11-01T23:59:59.000Z

    This project involves enhancement of the HWSIM distribution system model to more accurately model pipe heat transfer. Recent laboratory testing efforts have indicated that the modeling of radiant heat transfer effects is needed to accurately characterize piping heat loss. An analytical methodology for integrating radiant heat transfer was implemented with HWSIM. Laboratory test data collected in another project was then used to validate the model for a variety of uninsulated and insulated pipe cases (copper, PEX, and CPVC). Results appear favorable, with typical deviations from lab results less than 8%.

  7. Water Use in Agricultural Watersheds Derrel Martin, Professor, Irrigation and Water Resources Engineer, Dept. of Biological Systems

    E-Print Network [OSTI]

    Nebraska-Lincoln, University of

    Water Use in Agricultural Watersheds Derrel Martin, Professor, Irrigation and Water Resources Engineer, Dept. of Biological Systems Engineering, UNL Background Concerns about water use have intensified and Republican River Basins, and the implementation of LB 962. To understand water use it is helpful to consider

  8. Keywordscondensation tube, surface modification, waste heat and condensation water recovery system

    E-Print Network [OSTI]

    Leu, Tzong-Shyng "Jeremy"

    Keywordscondensation tube, surface modification, waste heat and condensation water recovery techniques is waste heat and condensation water recovery system. Waste heat and condensation water recovery system is one of the most important facilities in power plants. High efficiency waste heat

  9. Biofuels, land and water : a systems approach to sustainability.

    SciTech Connect (OSTI)

    Gopalakrishnan, G.; Negri, M. C.; Wang, M.; Wu, M.; Snyder, S. W.; LaFreniere, L.

    2009-08-01T23:59:59.000Z

    There is a strong societal need to evaluate and understand the sustainability of biofuels, especially because of the significant increases in production mandated by many countries, including the United States. Sustainability will be a strong factor in the regulatory environment and investments in biofuels. Biomass feedstock production is an important contributor to environmental, social, and economic impacts from biofuels. This study presents a systems approach where the agricultural, energy, and environmental sectors are considered as components of a single system, and environmental liabilities are used as recoverable resources for biomass feedstock production. We focus on efficient use of land and water resources. We conducted a spatial analysis evaluating marginal land and degraded water resources to improve feedstock productivity with concomitant environmental restoration for the state of Nebraska. Results indicate that utilizing marginal land resources such as riparian and roadway buffer strips, brownfield sites, and marginal agricultural land could produce enough feedstocks to meet a maximum of 22% of the energy requirements of the state compared to the current supply of 2%. Degraded water resources such as nitrate-contaminated groundwater and wastewater were evaluated as sources of nutrients and water to improve feedstock productivity. Spatial overlap between degraded water and marginal land resources was found to be as high as 96% and could maintain sustainable feedstock production on marginal lands. Other benefits of implementing this strategy include feedstock intensification to decrease biomass transportation costs, restoration of contaminated water resources, and mitigation of greenhouse gas emissions.

  10. Integrated system dynamics toolbox for water resources planning.

    SciTech Connect (OSTI)

    Reno, Marissa Devan; Passell, Howard David; Malczynski, Leonard A.; Peplinski, William J.; Tidwell, Vincent Carroll; Coursey, Don (University of Chicago, Chicago, IL); Hanson, Jason (University of New Mexico, Albuquerque, NM); Grimsrud, Kristine (University of New Mexico, Albuquerque, NM); Thacher, Jennifer (University of New Mexico, Albuquerque, NM); Broadbent, Craig (University of New Mexico, Albuquerque, NM); Brookshire, David (University of New Mexico, Albuquerque, NM); Chemak, Janie (University of New Mexico, Albuquerque, NM); Cockerill, Kristan (Cockeril Consulting, Boone, NC); Aragon, Carlos (New Mexico Univeristy of Technology and Mining (NM-TECH), Socorro, NM); Hallett, Heather (New Mexico Univeristy of Technology and Mining (NM-TECH), Socorro, NM); Vivoni, Enrique (New Mexico Univeristy of Technology and Mining (NM-TECH), Socorro, NM); Roach, Jesse

    2006-12-01T23:59:59.000Z

    Public mediated resource planning is quickly becoming the norm rather than the exception. Unfortunately, supporting tools are lacking that interactively engage the public in the decision-making process and integrate over the myriad values that influence water policy. In the pages of this report we document the first steps toward developing a specialized decision framework to meet this need; specifically, a modular and generic resource-planning ''toolbox''. The technical challenge lies in the integration of the disparate systems of hydrology, ecology, climate, demographics, economics, policy and law, each of which influence the supply and demand for water. Specifically, these systems, their associated processes, and most importantly the constitutive relations that link them must be identified, abstracted, and quantified. For this reason, the toolbox forms a collection of process modules and constitutive relations that the analyst can ''swap'' in and out to model the physical and social systems unique to their problem. This toolbox with all of its modules is developed within the common computational platform of system dynamics linked to a Geographical Information System (GIS). Development of this resource-planning toolbox represents an important foundational element of the proposed interagency center for Computer Aided Dispute Resolution (CADRe). The Center's mission is to manage water conflict through the application of computer-aided collaborative decision-making methods. The Center will promote the use of decision-support technologies within collaborative stakeholder processes to help stakeholders find common ground and create mutually beneficial water management solutions. The Center will also serve to develop new methods and technologies to help federal, state and local water managers find innovative and balanced solutions to the nation's most vexing water problems. The toolbox is an important step toward achieving the technology development goals of this center.

  11. Decision Support for IntegratedDecision Support for Integrated WaterWater--Energy PlanningEnergy Planning

    E-Print Network [OSTI]

    Keller, Arturo A.

    , a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security/Commercial -Industrial -Agriculture -Environment -Energy Energy Providers -Peak/Base -Generation Type -Location -Capacity Dynamics: BroadSystem Dynamics: Broad PerspectivePerspective Energy for Water Municipal Use Agriculture

  12. Monitoring microbial corrosion in large oilfield water systems

    SciTech Connect (OSTI)

    Chen, E.Y.; Chen, R.B.

    1983-03-01T23:59:59.000Z

    Monitoring of microbial corrosion is always difficult because of the sessile nature of bacteria and the lack of meaningful correlation between routine bacteria counts and bacterial activity. This problem is further aggravated in a large oilfield water system because of its size and sampling difficulties. This paper discusses some monitoring techniques currently used in the oil industry, their limitations and the possible areas for improvement. These suggested improvements either are presently being implemented or will be implemented in the Aramco systems.

  13. Monitoring microbial corrosion in large oilfield water systems

    SciTech Connect (OSTI)

    Chen, E.Y.; Chen, R.B.

    1984-07-01T23:59:59.000Z

    Monitoring of microbial corrosion is always difficult because of the sessile nature of bacteria and the lack of meaningful correlation between routine bacteria counts and bacterial activity. This problem is further aggravated in a large oilfield water system because of size and sampling difficulties. This paper discusses some monitoring techniques currently used in the oil industry, their limitations, and possible areas for improvement. These improved techniques are in use or will be implemented in the Aramco systems.

  14. Hydrocarbon Formation in Metallic Iron/Water Systems

    E-Print Network [OSTI]

    Deng, Baolin

    Hydrocarbon Formation in Metallic Iron/Water Systems B A O L I N D E N G , , § T I M O T H Y J . C-labeled hydrocarbons are produced. In the absence of chlorinated ethenes, however, lower con- centrations of many of the same hydrocarbons (methane and C2-C6 alkanes and alkenes) are also produced. Hardy and Gillham (1996

  15. EA-1905: Double Eagle Water System, Carlsbad, New Mexico

    Broader source: Energy.gov [DOE]

    This EA, prepared by the U.S. Department of the Interior’s Bureau of Land Management Carlsbad Field Office and adopted by DOE, evaluates the expansion and upgrade of the City of Carlsbad’s Double Eagle Water System.

  16. STATUS OF MUNICIPAL SOLID WASTE GENERATION IN KERALA AND THEIR CHARACTERISTICS

    E-Print Network [OSTI]

    Columbia University

    STATUS OF MUNICIPAL SOLID WASTE GENERATION IN KERALA AND THEIR CHARACTERISTICS Dr. R. Ajayakumar the generation of municipal solid waste (MSW) in Kerala beyond the assimilative of capacity of our environment and management capacity of the existing waste management systems. Therefore, there is an urgent necessity

  17. System Description for the KW Basin Integrated Water Treatment System (IWTS) (70.3)

    SciTech Connect (OSTI)

    DERUSSEAU, R.R.

    2000-04-18T23:59:59.000Z

    This is a description of the system that collects and processes the sludge and radioactive ions released by the spent nuclear fuel (SNF) processing operations conducted in the 105 KW Basin. The system screens, settles, filters, and conditions the basin water for reuse. Sludge and most radioactive ions are removed before the water is distributed back to the basin pool. This system is part of the Spent Nuclear Fuel Project (SNFP).

  18. Municipal Solid Waste in The United States

    E-Print Network [OSTI]

    Laughlin, Robert B.

    2007 Facts and Figures Municipal Solid Waste in The United States #12;United States Environmental Protection Agency Office of Solid Waste (5306P) EPA530-R-08-010 November 2008 www.epa.gov #12;MUNICIPAL SOLID ............................................................................................................................... 1 WHAT IS INCLUDED IN MUNICIPAL SOLID WASTE

  19. Advanced Characterisation of Municipal Solid Waste Ashes

    E-Print Network [OSTI]

    Advanced Characterisation of Municipal Solid Waste Ashes Preparatory thesis Randi Skytte Pedersen is to investigate Municipal Solid Waste (MSW) ashes with respect to particle sizes, structures and composition with characterisation of Municipal Solid Waste (MSW) ashes from the Danish power plant M°abjergværket, Holstebro. MSW

  20. Municipal Solid Waste in The United States

    E-Print Network [OSTI]

    Barlaz, Morton A.

    2011 Facts and Figures Municipal Solid Waste in The United States #12;United States Environmental Protection Agency Office of Solid Waste (5306P) EPA530-R-13-001 May 2013 www.epa.gov #12;MUNICIPAL SOLID WASTE IN THE UNITED STATES: 2011 FACTS AND FIGURES Table of Contents Chapter Page MUNICIPAL SOLID WASTE

  1. Study of the impacts of regulations affecting the acceptance of Integrated Community Energy Systems: public utility, energy facility siting and municipal franchising regulatory programs in the United States. Preliminary background report

    SciTech Connect (OSTI)

    Feurer, D.A.; Weaver, C.L.; Gallagher, K.C.; Hejna, D.; Rielley, K.J.

    1980-01-01T23:59:59.000Z

    This report is a summary of a series of preliminary reports describing the laws and regulatory programs of the United states and each of the 50 states affecting the siting and operation of energy generating facilities likely to be used in Integrated Community Energy Systems (ICES). A brief summary of public utility regulatory programs, energy facility siting programs, and municipal franchising authority is presented in this report to identify how such programs and authority may impact on the ability of an organization, whether or not it be a regulated utility, to construct and operate an ICES. Subsequent reports will (1) describe public utility rate regulatory procedures and practices as they might affect an ICES, (2) analyze each of the aforementioned regulatory programs to identify impediments to the development of ICES, and (3) recommend potential changes in legislation and regulatory practices and procedures to overcome such impediments.

  2. Study of the impacts of regulations affecting the acceptance of Integrated Community Energy Systems: public utility, energy facility siting and municipal franchising regulatory programs in the United States. Preliminary background report

    SciTech Connect (OSTI)

    Feurer, D.A.; Weaver, C.L.; Gallagher, K.C.; Hejna, D.; Rielley, K.J.

    1980-01-01T23:59:59.000Z

    This report is one of a series of preliminary reports describing the laws and regulatory programs of the United States and each of the 50 states affecting the siting and operation of energy generating facilities likely to be used in Integrated Community Energy Systems (ICES). Public utility regulatory statutes, energy facility siting programs, and municipal franchising authority are examined to identify how they may impact on the ability of an organization, whether or not it be a regulated utility, to construct and operate an ICES. This report describes laws and regulatory programs in the United States. Subsequent reports will (1) describe public utility rate regulatory procedures and practices as they might affect an ICES, (2) analyze each of the aforementioned regulatory programs to identify impediments to the development of ICES, and (3) recommend potential changes in legislation and regulatory practices and procedures to overcome such impediments.

  3. INTEC CPP-603 Basin Water Treatment System Closure: Process Design

    SciTech Connect (OSTI)

    Kimmitt, Raymond Rodney; Faultersack, Wendell Gale; Foster, Jonathan Kay; Berry, Stephen Michael

    2002-09-01T23:59:59.000Z

    This document describes the engineering activities that have been completed in support of the closure plan for the Idaho Nuclear Technology and Engineering Center (INTEC) CPP-603 Basin Water Treatment System. This effort includes detailed assessments of methods and equipment for performing work in four areas: 1. A cold (nonradioactive) mockup system for testing equipment and procedures for vessel cleanout and vessel demolition. 2. Cleanout of process vessels to meet standards identified in the closure plan. 3. Dismantlement and removal of vessels, should it not be possible to clean them to required standards in the closure plan. 4. Cleanout or removal of pipelines and pumps associated with the CPP-603 basin water treatment system. Cleanout standards for the pipes will be the same as those used for the process vessels.

  4. The Development of an Energy Evaluation Tool for Chilled Water Systems

    E-Print Network [OSTI]

    Stocki, M.; Kosanovic, D.; Ambs, L.

    An energy evaluation tool for chilled water systems was developed. This tool quantifies the energy usage of various chilled water systems and typical energy conservation measures that are applied to these systems. It can be used as a screening tool...

  5. Application of a water rights analysis program to reservoir system yield calculations

    E-Print Network [OSTI]

    Walls, William Brian

    1988-01-01T23:59:59.000Z

    corrected to approximate naturalized flows. As water management becomes more critical, it is necessary to gage the effect of governmental institutions on reservoir yields. In Texas and elsewhere, water users are governed by a system of water rights.... The effect of this system on firm yields must be quantified in order to provide effective water management. This thesis documents research into the effect of the Texas water rights system on the Brazos River Authority reservoir system. A new generalized...

  6. Physical Modeling of Scaled Water Distribution System Networks.

    SciTech Connect (OSTI)

    O'Hern, Timothy J.; Hammond, Glenn Edward; Orear, Leslie ,; van Bloemen Waanders, Bart G.; Paul Molina; Ross Johnson

    2005-10-01T23:59:59.000Z

    Threats to water distribution systems include release of contaminants and Denial of Service (DoS) attacks. A better understanding, and validated computational models, of the flow in water distribution systems would enable determination of sensor placement in real water distribution networks, allow source identification, and guide mitigation/minimization efforts. Validation data are needed to evaluate numerical models of network operations. Some data can be acquired in real-world tests, but these are limited by 1) unknown demand, 2) lack of repeatability, 3) too many sources of uncertainty (demand, friction factors, etc.), and 4) expense. In addition, real-world tests have limited numbers of network access points. A scale-model water distribution system was fabricated, and validation data were acquired over a range of flow (demand) conditions. Standard operating variables included system layout, demand at various nodes in the system, and pressure drop across various pipe sections. In addition, the location of contaminant (salt or dye) introduction was varied. Measurements of pressure, flowrate, and concentration at a large number of points, and overall visualization of dye transport through the flow network were completed. Scale-up issues that that were incorporated in the experiment design include Reynolds number, pressure drop across nodes, and pipe friction and roughness. The scale was chosen to be 20:1, so the 10 inch main was modeled with a 0.5 inch pipe in the physical model. Controlled validation tracer tests were run to provide validation to flow and transport models, especially of the degree of mixing at pipe junctions. Results of the pipe mixing experiments showed large deviations from predicted behavior and these have a large impact on standard network operations models.3

  7. Portable water filtration system for oil well fractionation

    SciTech Connect (OSTI)

    Seibert, D. L.

    1985-08-13T23:59:59.000Z

    The invention comprises a portable, multi-stage filtration system utilized in filtering water for an oil and gas stimulation process commonly known as fracking. Three stages are used, the first being a straining operation reducing the size of particulate matter in the water to about three-eighths of an inch. The second stage is a centrifugal separator, reducing the particle size to about 50 microns. The final stage utilizes a cartridge-type filter giving a final particle size in the water of about 5 microns. In this manner, water which is injected into the well head during the fracking process and which is obtained from readily available sources such as ponds, streams and the like is relatively free of particulate matter which can foul the fracking process. The invention, by virtue of being mounted on a trailer, is portable and thus can be easily moved from site to site. Water flow rates obtained using the invention are between 250 and 300 gallons per minute, sufficient for processing a small to medium sized well.

  8. Economic Analysis of a Waste Water Resource Heat Pump Air-Conditioning System in North China 

    E-Print Network [OSTI]

    Chen, H.; Li, D.; Dai, X.

    2006-01-01T23:59:59.000Z

    This paper describes the situation of waste water resource in north China and the characteristics and styles of a waste water resource heat pump system, and analyzes the economic feasibility of a waste water resource heat pump air...

  9. Economic Analysis of a Waste Water Resource Heat Pump Air-Conditioning System in North China

    E-Print Network [OSTI]

    Chen, H.; Li, D.; Dai, X.

    2006-01-01T23:59:59.000Z

    This paper describes the situation of waste water resource in north China and the characteristics and styles of a waste water resource heat pump system, and analyzes the economic feasibility of a waste water resource heat pump air...

  10. Phosphate and ammonium removal from waste water, using constructed wetland systems 

    E-Print Network [OSTI]

    Drizo, Aleksandra

    1998-01-01T23:59:59.000Z

    Phosphorus and nitrogen in waste water from sewerage systems contribute to excessive nutrient enrichment of surface waters, presenting a threat to nature conservation, domestic and industrial water supplies, and recreation. ...

  11. Water: Challenges at the Intersection of Human and Natural Systems

    SciTech Connect (OSTI)

    Futrell, J.H.; Gephart, R. E.; Kabat-Lensch, E.; McKnight, D. M.; Pyrtle, A.; Schimel, J. P.; Smyth, R. L.; Skole, D. L. Wilson, J. L.; Gephart, J. M.

    2005-09-01T23:59:59.000Z

    There is a growing recognition about the critical role water plays in sustaining people and society. This workshop established dialog between disciplinary scientists and program managers from diverse backgrounds in order to share perspectives and broaden community understanding of ongoing fundamental and applied research on water as a complex environmental problem. Three major scientific themes emerged: (1) coupling of cycles and process, with emphasis on the role of interfaces; (2) coupling of human and natural systems across spatial and temporal scales; and (3) prediction in the face of uncertainty. In addition, the need for observation systems, sensors, and infrastructure; and the need for data management and synthesis were addressed. Current barriers to progress were noted as educational and institutional barriers and the integration of science and policy.

  12. PURPOSE: This product provides simulation capabilities to allow water resource managers to meet operational and water quality objectives in a basin wide approach under the System-Wide

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Manage- ment System (CWMS). ERDC TN-SWWRP-11-2 February 2011 Meeting Water Quality and Water Control operational and water quality objectives in a basin wide approach under the System-Wide Water Resources the impact of water quality in reservoir operations system decision-making. As a result, integration

  13. Water Rights Analysis Package (WRAP) Modeling System Programming Manual

    E-Print Network [OSTI]

    Wurbs, R.; Hoffpauir, R.

    2012-10-01T23:59:59.000Z

    WRAP interface program was developed as a Fortran QuickWin application. SIM simulates the river/reservoir water allocation/management/use system for input sequences of monthly naturalized flows and net evaporation rates. (Chapter 2) SIMD (D for daily... management, and other utility functions. Many different Fortran compiler/IDE packages are sold by various companies. The WRAP programs are in standard Fortran that can be compiled with the various compilers. The compiler, linker, and development...

  14. Integrated supercritical water gasification combined cycle (IGCC) systems for improved performance and reduced operating costs in existing plants

    SciTech Connect (OSTI)

    Tolman, R.; Parkinson, W.J.

    1999-07-01T23:59:59.000Z

    A revolutionary hydrothermal heat recovery steam generator (HRSG) is being developed to produce clean fuels for gas turbines from slurries and emulsions of opportunity fuels. Water can be above 80% by weight and solids below 20%, including coal fines, coal water fuels, biomass, composted municipal refuse, sewage sludge and bitumen/Orimulsion. The patented HRSG tubes use a commercial method of particle scrubbing to improve heat transfer and prevent corrosion and deposition on heat transfer surfaces. A continuous-flow pilot plant is planned to test the HRSG over a wide range of operating conditions, including the supercritical conditions of water, above 221 bar (3,205 psia) and 374 C (705 F). Bench scale data shows, that supercritical water gasification below 580 C (1,076 F) and low residence time without catalysts or an oxidizer can produce a char product that can contain carbon up to the amount of fixed carbon in the proximate analysis of the solids in the feed. This char can be burned with coal in an existing combustion system to provide the heat required for gasification. The new HRSG tubes can be retrofitted into existing power plant boilers for repowering of existing plants for improved performance and reduced costs. A special condensing turbine allows final low-temperature cleaning and maintains quality and combustibility of the fuel vapor for modern gas turbine in the new Vapor Transmission Cycle (VTC). Increased power output and efficiency can be provided for existing plants, while reducing fuel costs. A preliminary computer-based process simulation model has been prepared that includes material and energy balances that simulate commercial-scale operations of the VTC on sewage sludge and coal. Results predict over 40% HHV thermal efficiency to electric power from sewage sludge at more than 83% water by weight. The system appears to become autothermal (no supplemental fuel required) at about 35% fixed carbon in the feed. Thus, bituminous and lignite coal slurries could be gasified at less than 25% coal and more than 75% water. Preliminary life cycle cost analyses indicate that disposal fees for sewage sludge improve operating economics over fuel that must be purchased, the cost and schedule advantages of natural gas-fired combined cycle systems are preserved. Sensitivity analyses show that increasing capital costs by 50% can be offset by an increase in sewage sludge disposal fees of $10/metric ton.

  15. Elements of an environmental decision support system for seasonal wetland salt management in a river basin subjected to water quality regulation

    SciTech Connect (OSTI)

    Quinn, N.W.T.

    2009-06-01T23:59:59.000Z

    Seasonally managed wetlands in the Grasslands Basin on the west-side of California's San Joaquin Valley provide food and shelter for migratory wildfowl during winter months and sport for waterfowl hunters during the annual duck season. Surface water supply to these wetlands contain salt which, when drained to the San Joaquin River during the annual drawdown period, can negatively impact water quality and cause concern to downstream agricultural riparian water diverters. Recent environmental regulation, limiting discharges salinity to the San Joaquin River and primarily targeting agricultural non-point sources, now also targets return flows from seasonally managed wetlands. Real-time water quality management has been advocated as a means of continuously matching salt loads discharged from agricultural, wetland and municipal operations to the assimilative capacity of the San Joaquin River. Past attempts to build environmental monitoring and decision support systems (EDSS's) to implement this concept have enjoyed limited success for reasons that are discussed in this paper. These reasons are discussed in the context of more general challenges facing the successful implementation of a comprehensive environmental monitoring, modelling and decision support system for the San Joaquin River Basin.

  16. Water spray ventilator system for continuous mining machines

    DOE Patents [OSTI]

    Page, Steven J. (Pittsburgh, PA); Mal, Thomas (Pittsburgh, PA)

    1995-01-01T23:59:59.000Z

    The invention relates to a water spray ventilator system mounted on a continuous mining machine to streamline airflow and provide effective face ventilation of both respirable dust and methane in underground coal mines. This system has two side spray nozzles mounted one on each side of the mining machine and six spray nozzles disposed on a manifold mounted to the underside of the machine boom. The six spray nozzles are angularly and laterally oriented on the manifold so as to provide non-overlapping spray patterns along the length of the cutter drum.

  17. Municipal solid-waste management in Istanbul

    SciTech Connect (OSTI)

    Kanat, Gurdal, E-mail: gkanat@gmail.co [Yildiz Teknik Universitesi Cevre Muh Bolumu, 34220 Davutpasa-Esenler, Istanbul (Turkey)

    2010-08-15T23:59:59.000Z

    Istanbul, with a population of around 13 million people, is located between Europe and Asia and is the biggest city in Turkey. Metropolitan Istanbul produces about 14,000 tons of solid waste per day. The aim of this study was to assess the situation of municipal solid-waste (MSW) management in Istanbul. This was achieved by reviewing the quantity and composition of waste produced in Istanbul. Current requirements and challenges in relation to the optimization of Istanbul's MSW collection and management system are also discussed, and several suggestions for solving the problems identified are presented. The recovery of solid waste from the landfills, as well as the amounts of landfill-generated biogas and electricity, were evaluated. In recent years, MSW management in Istanbul has improved because of strong governance and institutional involvement. However, efforts directed toward applied research are still required to enable better waste management. These efforts will greatly support decision making on the part of municipal authorities. There remains a great need to reduce the volume of MSW in Istanbul.

  18. Study of the impacts of regulations affecting the acceptance of Integrated Community Energy Systems: public utility, energy facility siting and municipal franchising regulatory programs in Washington. Preliminary background report

    SciTech Connect (OSTI)

    Feurer, D A; Weaver, C L; Gallagher, K C; Hejna, D; Rielley, K J

    1980-01-01T23:59:59.000Z

    The Washinton State Constitution grants authority to the legislature to regulate railroads and other common carriers as well as telegraph and telephone companies in the state. No section of the constitution expressly provides for the regulation of electric, gas, water, or heating utilities. The authority to regulate public utilities is vested generally in the Utilities and Transportation Commission, formerly designated at the Public Service Commission. The Commission is composed of three members appointed by the governor, with the consent of the senate. The term of office for commissioners is six years. Recently enacted legislation provides for the implementation of tax incentives to encourage the development of cogeneration facilities in the state. This plan is to be administered by the Department of Revenue in conjunction with the Energy Office. Public utility regulatory statutes, energy facility siting programs, and municipal franchising authority are examined to identify how they may impact on the ability of an organization, whether or not it be a regulated utility, to construct and operate an ICES.

  19. Santa Clara Water and Sewer- Solar Water Heating Program

    Broader source: Energy.gov [DOE]

    In 1975, the City of Santa Clara established the nation's first municipal solar utility. Under the Solar Water Heating Program, the Santa Clara Water and Sewer Utilities Department supplies,...

  20. The ASME handbook on water technology for thermal power systems

    SciTech Connect (OSTI)

    Cohen, P. (ed.)

    1989-01-01T23:59:59.000Z

    The idea that a handbook on water technology be developed was initially put forth in 1978 by the ASME Research Committee on Water in Thermal Power Systems. A prospectus was issued in 1979 to solicit funding from industry and government. The preparation of the handbook began in 1980 under the direct control of a Handbook Steering Subcommittee established by the Research Committee and an editor reporting to that subcommittee. Handbook content was carefully monitored by an editorial committee of industry experts and by a special honorary editorial committee from the Chemistry Committee of the Edison Electric Institute. This handbook summarizes the current state of the art of water technology for steam power plant cycles. It is intended to serve both as a training text and a reference volume for power station chemists, engineers, manufacturers, and research and development institutions. While the primary emphasis is on Electric Utility Power Generation cycles (fossil and nuclear), the book will also serve as a valuable reference on high pressure industrial steam system technology.

  1. Promising freeze protection alternatives in solar domestic hot water systems

    SciTech Connect (OSTI)

    Bradley, D.E.

    1997-12-31T23:59:59.000Z

    Since the gains associated with solar thermal energy technologies are comparatively small in relation to the required capital investment, it is vital to maximize conversion efficiency. While providing the necessary function of freeze protection, the heat exchanger commonly included in solar domestic water heating systems represents a system inefficiency. This thesis explores two alternate methods of providing freeze protection without resorting to a heat exchanger. Commonly, collectors are made of rigid copper tubes separated by copper or aluminum fins. Cracking damage can occur when water is allowed to freeze and expand inside the non compliant tubes. The possibility of making collectors out of an elastic material was investigated and shown to be effective. Since unlike copper, elastomers typically have low thermal conductivities, the standard collector performance prediction equations do not apply. Modified thermal performance prediction equations were developed which can be used for both low and high thermal conductivity materials to provide accurate predictions within a limited range of plate geometries. An elastomeric collector plate was then designed and shown to have comparable performance to a copper plate collector whose aperture area is approximately 33% smaller. Another options for providing freeze protection to an SDHW system is to turn it off during the winter. Choosing a three-season operating period means two things. First, the system will have different optimums such as slope and collector area. Second, the wintertime solar energy incident on the collector is unavailable for meeting a heating load. However, the system`s heat exchanger becomes unnecessary and removing it increases the amount of energy that arrives at the storage tank during those periods in which the system is operating.

  2. Spatial Water Balance in Texas

    E-Print Network [OSTI]

    Reed, Seann; Maidment, David; Patoux, Jerome

    Water availability is critical to the economy in the state of Texas. Numerous reservoirs and conveyance structures have been constructed across the State to meet the water supply needs of farmers, municipalities, industries, and power generating...

  3. The role of SCADA in developing a lean enterprise for municipal wastewater operations

    E-Print Network [OSTI]

    Prutz, Stanley J

    2005-01-01T23:59:59.000Z

    Central to optimizing a wastewater system's operations is the collection of alarm and operational data from various remote locations throughout a municipality, hence the basic need for supervisory control and data acquisition ...

  4. A three-phase K-value study for pure hydrocarbons/water and crude oil/water systems

    E-Print Network [OSTI]

    Lanclos, Ritchie Paul

    1990-01-01T23:59:59.000Z

    A THREE-PHASE K-VALUE STUDY FOR PURE HYDROCARBONS/WATER AND CRUDE OIL/WATER SYSTEMS A Thesis by RITCHIE PAUL LANCLOS Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements... of Committee) P. T. Eubank (Member) R. A. Wattenbar (Member) W. D. Von Gonten (Member) December 1990 ABSTRACT A Three-Phase K-Value Study for Pure Hydrocarbons/Water and Crude Oil/Water Systems Ritchie Paul Lanclos, B. S. , University...

  5. Graduate Opportunities in Earth Systems Modeling and Climate Impacts on Hydrology and Water Resources

    E-Print Network [OSTI]

    Graduate Opportunities in Earth Systems Modeling and Climate Impacts on Hydrology and Water research assistantships available in the general area of earth systems modeling and climate impacts

  6. Denton Municipal Electric- Standard Offer Rebate Program

    Broader source: Energy.gov [DOE]

    Within the GreenSense program, Denton Municipal Electric's Standard Offer Program provides rebates to large commercial and industrial customers for lighting retrofits, HVAC upgrades and motor...

  7. 2011 Municipal Consortium Northwest Region Workshop Materials

    Broader source: Energy.gov [DOE]

    This page provides links to the presentations given at the DOE Municipal Solid-State Street Lighting Consortium Northwest Region Workshop, held in Seattle July 15, 2011.

  8. Municipal Solid Waste Resources and Technologies

    Broader source: Energy.gov [DOE]

    This page provides a brief overview of municipal solid waste energy resources and technologies supplemented by specific information to apply waste to energy within the Federal sector.

  9. GHG emission factors developed for the recycling and composting of municipal waste in South African municipalities

    SciTech Connect (OSTI)

    Friedrich, Elena, E-mail: Friedriche@ukzn.ac.za; Trois, Cristina

    2013-11-15T23:59:59.000Z

    Highlights: • GHG emission factors for local recycling of municipal waste are presented. • GHG emission factors for two composting technologies for garden waste are included. • Local GHG emission factors were compared to international ones and discussed. • Uncertainties and limitations are presented and areas for new research highlighted. - Abstract: GHG (greenhouse gas) emission factors for waste management are increasingly used, but such factors are very scarce for developing countries. This paper shows how such factors have been developed for the recycling of glass, metals (Al and Fe), plastics and paper from municipal solid waste, as well as for the composting of garden refuse in South Africa. The emission factors developed for the different recyclables in the country show savings varying from ?290 kg CO{sub 2} e (glass) to ?19 111 kg CO{sub 2} e (metals – Al) per tonne of recyclable. They also show that there is variability, with energy intensive materials like metals having higher GHG savings in South Africa as compared to other countries. This underlines the interrelation of the waste management system of a country/region with other systems, in particular with energy generation, which in South Africa, is heavily reliant on coal. This study also shows that composting of garden waste is a net GHG emitter, releasing 172 and 186 kg CO{sub 2} e per tonne of wet garden waste for aerated dome composting and turned windrow composting, respectively. The paper concludes that these emission factors are facilitating GHG emissions modelling for waste management in South Africa and enabling local municipalities to identify best practice in this regard.

  10. Experimental Studies of NGNP Reactor Cavity Cooling System With Water

    SciTech Connect (OSTI)

    Corradini, Michael; Anderson, Mark; Hassan, Yassin; Tokuhiro, Akira

    2013-01-16T23:59:59.000Z

    This project will investigate the flow behavior that can occur in the reactor cavity cooling system (RCCS) with water coolant under the passive cooling-mode of operation. The team will conduct separate-effects tests and develop associated scaling analyses, and provide system-level phenomenological and computational models that describe key flow phenomena during RCCS operation, from forced to natural circulation, single-phase flow and two-phase flow and flashing. The project consists of the following tasks: Task 1. Conduct separate-effects, single-phase flow experiments and develop scaling analyses for comparison to system-level computational modeling for the RCCS standpipe design. A transition from forced to natural convection cooling occurs in the standpipe under accident conditions. These tests will measure global flow behavior and local flow velocities, as well as develop instrumentation for use in larger scale tests, thereby providing proper flow distribution among standpipes for decay heat removal. Task 2. Conduct separate-effects experiments for the RCCS standpipe design as two-phase flashing occurs and flow develops. As natural circulation cooling continues without an ultimate heat sink, water within the system will heat to temperatures approaching saturation , at which point two-phase flashing and flow will begin. The focus is to develop a phenomenological model from these tests that will describe the flashing and flow stability phenomena. In addition, one could determine the efficiency of phase separation in the RCCS storage tank as the two-phase flashing phenomena ensues and the storage tank vents the steam produced. Task 3. Develop a system-level computational model that will describe the overall RCCS behavior as it transitions from forced flow to natural circulation and eventual two-phase flow in the passive cooling-mode of operation. This modeling can then be used to test the phenomenological models developed as a function of scale.

  11. Solar Water Splitting: Photocatalyst Materials Discovery and Systems Development

    SciTech Connect (OSTI)

    McNulty, Thomas F.

    2008-05-02T23:59:59.000Z

    Hydrogen promises to be an attractive transportation fuel in the post-fossil fuel era. Relatively abundant and clean burning (water being the principal byproduct), hydrogen offers the potential to significantly reduce greenhouse gas emissions. However, there are significant technical barriers that require solutions before hydrogen can be implemented in large scale. These are: · Sources (e.g. hydrocarbon, water) · Transportation · Storage Each of the aforementioned barriers carries with it important considerations. First, would a hydrocarbon-based hydrogen source be of any benefit compared to conventional fossil fuels? Second, will a system based on centralized generation and distribution be viable? Finally, methods of on-board storage, whether they are liquefaction, adsorption, or intercalation, are far from optimized. The scope of this program is limited to hydrogen generation, specifically generation using solarinitiated water electrolysis. Though concept of making hydrogen using water and sunlight may sound somewhat far-fetched, in reality the concept is very real. Since the discovery of solar-generated hydrogen, termed photoelectrochemical hydrogen, nearly 30 years ago by Fujishima and Honda, significant advances in both fundamental understanding and technological capability have been made. Using solar radiation to generate hydrogen in a fashion akin to using solar to generate electricity offers many advantages. First, hydrogen can be generated at the point of use, reducing the importance of transportation. Second, using water as the hydrogen source eliminates greenhouse gas evolution and the consequences that come with it. Finally, because the process uses very little electricity (pumps and compressors predominantly), the quantity of chemical fuel produced far exceeds the amount of electricity consumed. Consequently, there is some level of truth to the notion that photoelectrochemically-derived hydrogen offers the potential to nearly eliminate greenhouse gas emissions from the transportation landscape. This report focuses primarily on the technical issues inherent to developing an economically viable photoelectrochemical hydrogen system. This involves research intended to address technology gaps as well as research to address commercial feasibility. Though a firm cost target is not identified explicitly, much of the economics are presented in terms of “dollars per gallon of gasoline equivalent” ($/gge). Obviously this is a moving target, but it is important to understand cost in terms of current gasoline pricing, since the intended target is gasoline replacement. However, this does put the cost contribution into a perspective that at least allows for a reasonable assessment of technological viability. It also allows for the identification of need areas beyond the obvious technology gaps.

  12. Automation of Pivot Sprinkler Irrigation Systems to More Efficiently Utilize Rainfall and Irrigation Water

    E-Print Network [OSTI]

    Wendt, C. W.; Runkles, J. R.; Gerst, M. D.; Harbert, H. P. III; Hutmacher, R. B.

    A study was conducted to develop automated pivot sprinkler irrigation systems and determine if such systems use less water and energy than manually operated systems. The study was conducted near Earth, Texas, using irrigation systems located...

  13. Water sensors with cellular system eliminate tail water drainage in alfalfa irrigation

    E-Print Network [OSTI]

    Saha, Rajat; Raghuwanshi, Narendra S; Upadhyaya, Shrinivasa K; Wallender, Wesley W.; Slaughter, David C

    2011-01-01T23:59:59.000Z

    2003. Improving irrigation water management of alfalfa. In:number, sensor number and water arrival time. Wire meshplate Terminals Fig. 1. The water-arrival, or wetting-front,

  14. Dolomitization by ground-water flow systems in carbonate platforms

    SciTech Connect (OSTI)

    Simms, M.

    1984-09-01T23:59:59.000Z

    Dolomite occurs throughout the subsurface of modern carbonate platforms such as the Bahamas. Groundwater flow systems must be responsible for delivery of reactants needed for dolomitization. Reflux, freshwater lens flows, and thermal convection are large-scale flow systems that may be widespread in active platforms. The author has evaluated some aspects of the dynamics and characteristics of these processes with ground-water flow theory and by scaled sandbox experiments. Reflux is not restricted to hypersaline brines, but can occur with bankwaters of only slightly elevated salinity such as those found on the Bahama Banks today (42%). The lack of evaporites in a stratigraphic section, therefore, does not rule out the possibility that reflux may have operated. Flows associated with freshwater lenses include flow in the lens, in the mixing zone, and in the seawater beneath and offshore of the lens. Upward transfer of seawater through the platform margins occurs when surrounding cold ocean water migrates into the platform and is heated. This type of thermal convection (Kohout convection) has been studied by Francis Kohout in south Florida. The ranges of mass flux of magnesium in these processes are all comparable and are all sufficient to account for young dolomites beneath modern platforms. Each process yields dolomitized zones of characteristic shape and location and perhaps may be distinguishable in ancient rocks. The concepts presented here may have application to exploration for dolomite reservoirs in the Gulf Coast and elsewhere.

  15. Acceptance test procedure for High Pressure Water Jet System

    SciTech Connect (OSTI)

    Crystal, J.B.

    1995-05-30T23:59:59.000Z

    The overall objective of the acceptance test is to demonstrate a combined system. This includes associated tools and equipment necessary to perform cleaning in the 105 K East Basin (KE) for achieving optimum reduction in the level of contamination/dose rate on canisters prior to removal from the KE Basin and subsequent packaging for disposal. Acceptance tests shall include necessary hardware to achieve acceptance of the cleaning phase of canisters. This acceptance test procedure will define the acceptance testing criteria of the high pressure water jet cleaning fixture. The focus of this procedure will be to provide guidelines and instructions to control, evaluate and document the acceptance testing for cleaning effectiveness and method(s) of removing the contaminated surface layer from the canister presently identified in KE Basin. Additionally, the desired result of the acceptance test will be to deliver to K Basins a thoroughly tested and proven system for underwater decontamination and dose reduction. This report discusses the acceptance test procedure for the High Pressure Water Jet.

  16. Operating experience of a chilled water storage system

    SciTech Connect (OSTI)

    Pierpoint, T.J.; Marsilii, J.A.

    1986-03-01T23:59:59.000Z

    The Potomac Electric Power Company (PEPCO) is actively studying methods, such as Thermal Energy Storage (TES), to reduce the summer peak growth rate. TES is a technology that can provide significant reductions in the summer on-peak demand level thereby aiding building owners in reducing their operating costs while helping utilities reduce summer peak load growth. From analysis of PEPCO's chilled water storage system in its Forestville, MD office building it is evident that for demand reduction to be achieved significant consideration must be placed in the operational strategies chosen for the TES system. The chiller priority strategy was chosen because it is straightforward to implement and provides security that stored chilled water will always be available. The building, operating under the chiller priority scenario, accomplished a maximum load reduction 20 kW in 1985 and an average summer season load reduction of 13.5 kW. Demand reductions of up to 50 kW were expected but not achieved largely due to the operational strategies chosen. An alternative approach is storage priority. If storage priority had been implemented for the 1985 cooling season, analysis indicate that the expected demand reductions of 50 kW could have been achieved. 7 figures, 2 tables.

  17. Performance Evaluation of Hot Water Efficiency Plumbing System Using Thermal Valve

    E-Print Network [OSTI]

    Cha, K. S.; Park, M. S.; Seo, H. Y.

    hot water piping system, Thermo controlled valve, Circulation, Mixing water pipe, Recirculation water pipe INTRODUCTION Finding ways to conserve energy while heating a building?s water supply can be approached from a number of angles. Still...?s disadvantage is that so much water is wasted until the optimal tap temperature is reached.(6) We tried to solve this problem by developing a water-saving hot water plumbing system that utilizes a thermo-controlled valve. The goal was to not allow...

  18. Water Rights Analysis Package (WRAP) Modeling System Reference Manual

    E-Print Network [OSTI]

    Wurbs, R.

    2012-10-01T23:59:59.000Z

    The Texas Water Resources Institute (TWRI), and many other agencies and organizations, have worked with Ralph Wurbs over the years to develop WRAP (the Water Rights Analysis Package). The WRAP model simulates management of the water resources of a...

  19. DESIGN OF A RURAL WATER PROVISION SYSTEM TO DECREASE ARSENIC EXPOSURE IN BANGLADESH

    E-Print Network [OSTI]

    Agogino, Alice M.

    in fractions versus all at once); (3) allowing water to first stand for two to three days followed by treatment with ARUBA produced final arsenic concentrations ten times lower than treating water directly out of the well-scale water treatment system that uses ARUBA to remove arsenic from drinking water. We have constructed

  20. New Advanced System Utilizes Industrial Waste Heat to Power Water...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    is crucial to ensuring their status as global competitors. Currently, most industries treat water to meet standards for direct discharge to surface water. The process includes a...

  1. Aging study of boiling water reactor high pressure injection systems

    SciTech Connect (OSTI)

    Conley, D.A.; Edson, J.L.; Fineman, C.F. [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)

    1995-03-01T23:59:59.000Z

    The purpose of high pressure injection systems is to maintain an adequate coolant level in reactor pressure vessels, so that the fuel cladding temperature does not exceed 1,200{degrees}C (2,200{degrees}F), and to permit plant shutdown during a variety of design basis loss-of-coolant accidents. This report presents the results of a study on aging performed for high pressure injection systems of boiling water reactor plants in the United States. The purpose of the study was to identify and evaluate the effects of aging and the effectiveness of testing and maintenance in detecting and mitigating aging degradation. Guidelines from the United States Nuclear Regulatory Commission`s Nuclear Plant Aging Research Program were used in performing the aging study. Review and analysis of the failures reported in databases such as Nuclear Power Experience, Licensee Event Reports, and the Nuclear Plant Reliability Data System, along with plant-specific maintenance records databases, are included in this report to provide the information required to identify aging stressors, failure modes, and failure causes. Several probabilistic risk assessments were reviewed to identify risk-significant components in high pressure injection systems. Testing, maintenance, specific safety issues, and codes and standards are also discussed.

  2. Alameda Municipal Power - Residential Energy Efficiency Program...

    Broader source: Energy.gov (indexed) [DOE]

    Motors: 0.18per kWh saved Lighting: 0.20per kWh saved HVAC: 0.22per kWh saved Refrigeration: 0.22per kWh saved Provider Alameda Municipal Power Alameda Municipal Power...

  3. Department of Mechanical and Nuclear Engineering Spring 2012 Automatic Plant Watering System

    E-Print Network [OSTI]

    Demirel, Melik C.

    PENNSTATE Department of Mechanical and Nuclear Engineering Spring 2012 Automatic Plant Watering System Overview The goal of this project was to design an automatic plant watering system for commercial in the soil of household plants and delivery water to those plants on a need-only basis. The overall design

  4. Federal, Municipal, Universities and Other ESPC Case Studies...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Federal, Municipal, Universities and Other ESPC Case Studies from Different States Federal, Municipal, Universities and Other ESPC Case Studies from Different States Provides a...

  5. Toward Energy Efficient Municipalities: General Comments on Policy...

    Energy Savers [EERE]

    Energy Efficient Municipalities: General Comments on Policy and Logistical Challenges to Smart Grid Implementation Toward Energy Efficient Municipalities: General Comments on...

  6. Design Case Summary: Production of Mixed Alcohols from Municipal...

    Office of Environmental Management (EM)

    Mixed Alcohols from Municipal Solid Waste via Gasification Design Case Summary: Production of Mixed Alcohols from Municipal Solid Waste via Gasification The Bioenergy Technologies...

  7. Oklahoma Municipal Power Authority- Commercial and Industrial Energy Efficiency Program

    Broader source: Energy.gov [DOE]

    The Oklahoma Municipal Power Authority (OMPA) offers the Demand and Energy Efficiency Program (DEEP) to eligible commercial, industrial, and municipal government customers served by OMPA. This...

  8. February 19, 2013 Webinar: Exploring How Municipal Utilities...

    Energy Savers [EERE]

    February 19, 2013 Webinar: Exploring How Municipal Utilities Fund Solar Energy Projects February 19, 2013 Webinar: Exploring How Municipal Utilities Fund Solar Energy Projects This...

  9. Wakefield Municipal Gas and Light Department- Residential Conservation Services Program

    Broader source: Energy.gov [DOE]

    The Wakefield Municipal Gas and Light Department (WMGLD), in cooperation with the Massachusetts Municipal Wholesale Electric Company (MMWEC), offers the "Incentive Rebate Program" to encourage...

  10. State Clean Energy Policies Analysis: State, Utility, and Municipal...

    Open Energy Info (EERE)

    State, Utility, and Municipal Loan Programs Jump to: navigation, search Name State Clean Energy Policies Analysis: State, Utility, and Municipal Loan Programs AgencyCompany...

  11. Municipal Solid Waste (MSW) to Liquid Fuels Synthesis, Volume...

    Office of Environmental Management (EM)

    1: Availability of Feedstock and Technology Municipal Solid Waste (MSW) to Liquid Fuels Synthesis, Volume 1: Availability of Feedstock and Technology Municipal solid waste (MSW) is...

  12. Silicon Valley Power and Oklahoma Municipal Power Authority Win...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Silicon Valley Power and Oklahoma Municipal Power Authority Win 2014 Public Power Wind Awards Silicon Valley Power and Oklahoma Municipal Power Authority Win 2014 Public Power Wind...

  13. Summary of resources available to small water systems for meeting the 10 ppb arsenic drinking water limit.

    SciTech Connect (OSTI)

    Krumhansl, James Lee; Thomson, Bruce M. (University of New Mexico, Albuquerque, NM); Ziegler, Matt (New Mexico Tech, Albuquerque, NM); Butler, Susan (New Mexico Tech, Albuquerque, NM); Himmelberger, Heather (New Mexico Tech, Albuquerque, NM); Holt, Kathleen Caroline

    2007-01-01T23:59:59.000Z

    With the lowering of the EPA maximum contaminant level of arsenic from 50 parts per billion (ppb) to 10 ppb, many public water systems in the country and in New Mexico in particular, are faced with making decisions about how to bring their system into compliance. This document provides detail on the options available to the water systems and the steps they need to take to achieve compliance with this regulation. Additionally, this document provides extensive resources and reference information for additional outreach support, financing options, vendors for treatment systems, and media pilot project results.

  14. Modeling the Global Water Resource System in an Integrated Assessment Modeling Framework: IGSM-WRS

    E-Print Network [OSTI]

    Strzepek, Kenneth M.

    The availability of water resources affects energy, agricultural and environmental systems, which are linked together as well as to climate via the water cycle. As such, watersheds and river basins are directly impacted ...

  15. Complex Adaptive Systems Simulation-Optimization Framework for Adaptive Urban Water Resources Management

    E-Print Network [OSTI]

    Giacomoni, Marcio

    2012-10-19T23:59:59.000Z

    Population growth, urbanization and climate change threaten urban water systems. The rise of demands caused by growing urban areas and the potential decrease of water availability caused by the increase of frequency and severity of droughts...

  16. Seasonal Performance Variations for Storm-Water Management Systems in Cold Climate Conditions

    E-Print Network [OSTI]

    headings: Stormwater management; Best management practice; Performance characteristics; Water qualitySeasonal Performance Variations for Storm-Water Management Systems in Cold Climate Conditions. An examination of six varied LID designs, in contrast with conventional best-management practices BMPs

  17. Pressurized water nuclear reactor system with hot leg vortex mitigator

    DOE Patents [OSTI]

    Lau, Louis K. S. (Monroeville, PA)

    1990-01-01T23:59:59.000Z

    A pressurized water nuclear reactor system includes a vortex mitigator in the form of a cylindrical conduit between the hot leg conduit and a first section of residual heat removal conduit, which conduit leads to a pump and a second section of residual heat removal conduit leading back to the reactor pressure vessel. The cylindrical conduit is of such a size that where the hot leg has an inner diameter D.sub.1, the first section has an inner diameter D.sub.2, and the cylindrical conduit or step nozzle has a length L and an inner diameter of D.sub.3 ; D.sub.3 /D.sub.1 is at least 0.55, D.sub.2 is at least 1.9, and L/D.sub.3 is at least 1.44, whereby cavitation of the pump by a vortex formed in the hot leg is prevented.

  18. Testing of a portable ultrahigh pressure water decontamination system (UHPWDS)

    SciTech Connect (OSTI)

    Lovell, A.; Dahlby, J.

    1996-02-01T23:59:59.000Z

    This report describes the tests done with a portable ultrahigh pressure water decontamination system (UHPWDS) on highly radioactively contaminated surfaces. A small unit was purchased, modified, and used for in-situ decontamination to change the waste level of the contaminated box from transuranic (TRU) waste to low- level waste (LLW). Low-level waste is less costly by as much as a factor of five or more if compared with TRU waste when handling, storage, and disposal are considered. The portable unit we tested is commercially available and requires minimal utilities for operation. We describe the UHPWDS unit itself, a procedure for its use, the results of the testing we did, and conclusions including positive and negative aspects of the UHPWDS.

  19. Isobaric vapor-liquid equilibria for methanol + ethanol + water and the three constituent binary systems

    SciTech Connect (OSTI)

    Kurihara, Kiyofumi; Nakamichi, Mikiyoshi; Kojima, Kazuo (Nihon Univ., Tokyo (Japan). Dept. of Industrial Chemistry)

    1993-07-01T23:59:59.000Z

    Vapor-liquid equilibrium data for methanol + ethanol + water and its three constituent binary systems methanol + ethanol, ethanol + water, and methanol + water were measured at 101.3 kPa using a liquid-vapor ebullition-type equilibrium still. The experimental binary data were correlated by the NRTL equation. The ternary system methanol + ethanol + water was predicted by means of the binary NRTL parameters with good accuracy.

  20. Best Management Practice #14: Alternative Water Sources

    Broader source: Energy.gov [DOE]

    Many federal facilities may have water uses that can be met with non-potable water from alternative water sources. Potentially available alternative water sources for Federal sources include municipal-supplied reclaimed water, treated gray water from on-site sanitary sources, and storm water.

  1. The Full Water Disposal Ways and Study on Central Air-conditioning Circulation Cooling Water System

    E-Print Network [OSTI]

    Zhang, J.

    2006-01-01T23:59:59.000Z

    This paper has been made the further study about the water quality issue of the central air-conditioning circulation cooling water. Based on the comparison of the existing common adopted disposal ways, put forward the new ways of combination...

  2. Reservoir/River System Reliability Considering Water Rights and Water Quality

    E-Print Network [OSTI]

    Wurbs, Ralph A.; Sanchez-Torres, Gerardo; Dunn, David D.

    Effective management of the highly variable water resources of a river basin requires an understanding of the amount of suitable quality water that can be provided under various conditions within institutional constraints. Although much research has...

  3. The design and evaluation of a water delivery system for evaporative cooling of a proton exchange membrane fuel cell

    E-Print Network [OSTI]

    Al-Asad, Dawood Khaled Abdullah

    2009-06-02T23:59:59.000Z

    An investigation was performed to demonstrate system design for the delivery of water required for evaporative cooling of a proton exchange membrane fuel cell (PEMFC). The water delivery system uses spray nozzles capable of injecting water directly...

  4. The design and evaluation of a water delivery system for evaporative cooling of a proton exchange membrane fuel cell 

    E-Print Network [OSTI]

    Al-Asad, Dawood Khaled Abdullah

    2009-06-02T23:59:59.000Z

    An investigation was performed to demonstrate system design for the delivery of water required for evaporative cooling of a proton exchange membrane fuel cell (PEMFC). The water delivery system uses spray nozzles capable of injecting water directly...

  5. Fourier transform microwave spectrum of the propane-water complex: A prototypical water-hydrophobe system

    E-Print Network [OSTI]

    Cohen, Ronald C.

    Fourier transform microwave spectrum of the propane-water complex: A prototypical water) The Fourier transform microwave spectrum of the propane-water complex (C3H,-H,O) has been observed and analyzed. This spectrum includes transitions assigned to propane complexed with both the ortho and para

  6. Robust Energy Cost Optimization of Water Distribution System with ...

    E-Print Network [OSTI]

    2011-02-21T23:59:59.000Z

    Energy cost optimization of a water-supply network is a very important practical .... nonlinear equations for energy conservation. .... [water balance equations] ...... Israel Institute of Technology, Technion, Technion City, Haifa 32000, Israel.

  7. Boiler System Efficiency Improves with Effective Water Treatment

    E-Print Network [OSTI]

    Bloom, D.

    Water treatment is an important aspect of boiler operation which can affect efficiency or result in damage if neglected. Without effective water treatment, scale can form on boiler tubes, reducing heat transfer, and causing a loss of boiler...

  8. Solar Water Heating with Low-Cost Plastic Systems (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2012-01-01T23:59:59.000Z

    Newly developed solar water heating technology can help Federal agencies cost effectively meet the EISA requirements for solar water heating in new construction and major renovations. This document provides design considerations, application, economics, and maintenance information and resources.

  9. Modeling the water consumption of Singapore using system dynamics

    E-Print Network [OSTI]

    Welling, Karen Noiva

    2011-01-01T23:59:59.000Z

    Water resources are essential to life, and in urban areas, the high demand density and finite local resources often engender conditions of relative water scarcity. To overcome this scarcity, governments intensify infrastructure ...

  10. Systematization of water allocation systems: an engineering approach

    E-Print Network [OSTI]

    Santos Roman, Deborah Matilde

    2007-04-25T23:59:59.000Z

    Analysis Package (WRAP) model in supporting water allocation efforts. The Lower Rio Grande WAS was used as a case study to demonstrate how the principles presented in the conceptual framework can be used to assess water allocation issues and identify...

  11. Aerosol behavior experiments on light water reactor primary systems

    SciTech Connect (OSTI)

    Rahn, F.J.; Collen, J.; Wright, A.L.

    1988-05-01T23:59:59.000Z

    The results of three experimental programs relevant to the behavior of aerosols in the primary systems of light water reactors (LWRs) are presented. These are the Large-Scale Aerosol Transport Test programs performed at the Marviken test facility in Sweden, parts of the LWR Aerosol Containment Experiments (LACE) performed at the Hanford Engineering Development Laboratory, and the TRAP-MELT validation project performed at Oak Ridge National Laboratory. The Marviken experiments focused on the behavior of aerosols released from fuel and structural materials in a damaged core. Data on the transport of these aerosols and their physical characteristics were obtained in five experiments that simulated LWR primary systems. The LACE program data include results from the containment bypass accident tests, which focused on aerosol transport in pipes. The TRAP-MELT validation project data include results from two types of experiments: (a) aerosol transport tests to investigate aerosol wall plateout in a vertical pipe geometry and (b) aerosol resuspension tests to provide a data base from which analytical models can be developed. Typical results from these programs are presented and discussed.

  12. A Free Cooling Based Chilled Water System at Kingston

    E-Print Network [OSTI]

    Jansen, P. R.

    1984-01-01T23:59:59.000Z

    to the concept of cooling chilled water with condenser water via plate heat exchangers. The other free cooling scheme considered was a process called 'strainer cycle'. In strainer cycle, the cooling tower water is pumped directly into the chilled water... and process equipment and the CDD's (coolant distribution units) of computers installed and on test. Additionally, switchover to strainer cycle would be more time consuming and difficult. For a high technology site the switch over must be smooth...

  13. Modeling the large-scale water balance impact of different irrigation systems

    E-Print Network [OSTI]

    Evans, Jason

    Modeling the large-scale water balance impact of different irrigation systems J. P. Evans1 and B. F precipitation causes the Turkish government to invest in modernizing its own irrigation systems balance impact of different irrigation systems, Water Resour. Res., 44, W08448, doi:10.1029/2007WR006671

  14. Water Supply Planning Using an Expert Geographic Information System

    E-Print Network [OSTI]

    McKinney, Daene C.; Burgin, John F.; Maidment, David R.

    supply and demand data; and a network flow solver, to balance the flows in networks developed by the expert GIS with input from a water resource analyst. Commonly available water demand forecasts and water supply data are used in this new planning tool...

  15. Arizona law now requires that community water systems record and submit an Annual Water Use Report and Sys-

    E-Print Network [OSTI]

    Fay, Noah

    of this project was to develop an online drought trigger analysis tool and supporting guidance materials to help community water systems more effectively assess their drought risk and make informed decisions to prevent systems need indicators and triggers for each stage. No such tool was previously available. PROJECT TEAM

  16. A Simple and Quick Chilled Water Loop Balancing for Variable Flow System

    E-Print Network [OSTI]

    Zhu, Y.; Batten, T.; Turner, W. D.; Claridge, D. E.; Liu, M.

    2000-01-01T23:59:59.000Z

    system is reduced by about 40%. Key words: chilled water, loop, riser, balancing, commissioning, cold deck, pump, energy consumption, EMCS. INTRODUCTION Variable flow pumping systems are becoming more prevalent in the chilled water loops or risers... the building owner, facility engineers or HVAC operators more opportunities to run the chilled water system more efficiently. Generally, the pump speeds are controlled by the EMCS or a stand-alone controller to maintain the differential pressure setpoints...

  17. Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corp. , Columbus, Ohio. Final report

    SciTech Connect (OSTI)

    None

    1980-11-01T23:59:59.000Z

    The Solar Energy System located at the Columbia Gas Corporation, Columbus, Ohio, has 2978 ft/sup 2/ of Honeywell single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/h Bryan water-tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton Arkla hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts are included from the site files, specification references, drawings, installation, operation and maintenance instructions.

  18. Storm-water management for construction activities. Developing pollution prevention plans and best management practices

    SciTech Connect (OSTI)

    Not Available

    1992-09-01T23:59:59.000Z

    The manual provides industrial facilities with comprehensive guidance on the development of storm water pollution prevention plans and identification of appropriate Best Management Practices (BMPs). It provides technical assistance and support to all facilities subject to pollution prevention requirements established under National Pollutant Discharge Elimination System (NPDES) permits for storm water point source discharges. EPA's storm water program significantly expands the scope and application of the existing NPDES permit system for municipal and industrial process wastewater discharges. It emphasizes pollution prevention and reflects a heavy reliance on BMPs to reduce pollutant loadings and improve water quality. The manual provides essential guidance in both of these areas.

  19. Storm-water management for industrial activities. Developing pollution prevention plans and best management practices

    SciTech Connect (OSTI)

    Not Available

    1992-09-01T23:59:59.000Z

    The manual provides industrial facilities with comprehensive guidance on the development of storm water pollution prevention plans and identification of appropriate Best Management Practices (BMPs). It provides technical assistance and support to all facilities subject to pollution prevention requirements established under National Pollutant Discharge Elimination System (NPDES) permits for storm water point source discharges. EPA's storm water program significantly expands the scope and application of the existing NPDES permit system for municipal and industrial process wastewater discharges. It emphasizes pollution prevention and reflects a heavy reliance on BMPs to reduce pollutant loadings and improve water quality. The manual provides essential guidance in both of these areas.

  20. Cost-efficient monitoring of water quality in district heating systems This article examines the monitoring strategy for water quality in a large Danish district

    E-Print Network [OSTI]

    Cost-efficient monitoring of water quality in district heating systems This article examines the monitoring strategy for water quality in a large Danish district heating system ­ and makes a proposal for a technical and economic improvement. Monitoring of water quality in district heating systems is necessary

  1. A satellite ocean color observation operator system for eutrophication assessment in coastal waters

    E-Print Network [OSTI]

    Fontana, Clément

    A satellite ocean color observation operator system for eutrophication assessment in coastal waters: Satellite ocean color Observation operator Eutrophication Remote sensing Radiative transfer modeling

  2. Improved Design Tools for Surface Water and Standing Column Well Heat Pump Systems

    Broader source: Energy.gov [DOE]

    This project will improve the capability of engineers to design heat pump systems that utilize surface water or standing column wells (SCW) as their heat sources and sinks.

  3. Integrated Water Treatment System (IWTS) Process Flow Diagram Mass Balance Calculations for K West Basin

    SciTech Connect (OSTI)

    REED, A.V.

    2000-02-28T23:59:59.000Z

    The purpose of this calculation is to develop the rational for the material balances that are documented in the KW Basin water system Level 1 process flow diagrams.

  4. Hydrogen from Water in a Novel Recombinant Cyanobacterial System

    SciTech Connect (OSTI)

    Weyman, Philip D [J. Craig Venter Institute; Smith, Hamillton O.

    2014-12-03T23:59:59.000Z

    Photobiological processes are attractive routes to renewable H2 production. With the input of solar energy, photosynthetic microbes such as cyanobacteria and green algae carry out oxygenic photosynthesis, using sunlight energy to extract protons and high energy electrons from water. These protons and high energy electrons can be fed to a hydrogenase system yielding H2. However, most hydrogen-evolving hydrogenases are inhibited by O2, which is an inherent byproduct of oxygenic photosynthesis. The rate of H2 production is thus limited. Certain photosynthetic bacteria are reported to have an O2-tolerant evolving hydrogenase, yet these microbes do not split water, and require other more expensive feedstocks. To overcome these difficulties, the goal of this work has been to construct novel microbial hybrids by genetically transferring O2-tolerant hydrogenases from other bacteria into a class of photosynthetic bacteria called cyanobacteria. These hybrid organisms will use the photosynthetic machinery of the cyanobacterial hosts to perform the water-oxidation reaction with the input of solar energy, and couple the resulting protons and high energy electrons to the O2-tolerant bacterial hydrogenase, all within the same microbe (Fig. 1). The ultimate goal of this work has been to overcome the sensitivity of the hydrogenase enzyme to O2 and address one of the key technological hurdles to cost-effective photobiological H2 production which currently limits the production of hydrogen in algal systems. In pursuit of this goal, work on this project has successfully completed many subtasks leading to a greatly increased understanding of the complicated [NiFe]-hydrogenase enzymes. At the beginning of this project, [NiFe] hydrogenases had never been successfully moved across wide species barriers and had never been heterologously expressed in cyanobacteria. Furthermore, the idea that whole, functional genes could be extracted from complicated, mixed-sequence meta-genomes was not established. In the course of this work, we identified a new hydrogenase from environmental DNA sequence and successfully expressed it in a variety of hosts including cyanobacteria. This was one of the first examples of these complicated enzymes being moved across vastly different bacterial species and is the first example of a hydrogenase being “brought to life” from no other information than a DNA sequence from metagenomic data. The hydrogenase we identified had the molecular signature of other O2-tolerant hydrogenases, and we discovered that the resulting enzyme had exceptionally high oxygen- and thermo-tolerance. The new enzyme retained 80% of its activity after incubation at 80° C for 2 hours and retained 20% activity in 1% O2. We performed detailed analysis on the maturation genes required for construction of a functional enzyme of this class of hydrogenase, and found that seven additional maturation genes were required for minimal activity and a total of nine genes besides the hydrogenase were required for optimal maturation efficiency. Furthermore, we demonstrated that the maturation genes are functional on closely-related hydrogenase enzymes such as those from Alteromonas macleodii and Thiocapsa roseopersicina. Finally, we have extensively modified the hydrogenase to engineer new traits including higher H2 production and better interaction with electron donors. For example, combining two strategies increased hydrogenase activity in cyanobacteria by at least 20-fold over our initial expression level. The activity of this combined strain is almost twice that of the native hydrogenase activity in S. elongatus. This work validates the idea that these enzymes are broadly tolerant to modifications that may help integrate them into a successful photobiological H2 production system. While we did not achieve our ultimate goal of integrating the functional hydrogenase with the cyanobacterial photosynthetic apparatus, the work on this project has led to significant advances in the understanding of these complicated enzymes. This work will greatly benefit future

  5. Evaluating Domestic Hot Water Distribution System Options With Validated Analysis Models

    SciTech Connect (OSTI)

    Weitzel, E.; Hoeschele, M.

    2014-09-01T23:59:59.000Z

    A developing body of work is forming that collects data on domestic hot water consumption, water use behaviors, and energy efficiency of various distribution systems. A full distribution system developed in TRNSYS has been validated using field monitoring data and then exercised in a number of climates to understand climate impact on performance. This study builds upon previous analysis modelling work to evaluate differing distribution systems and the sensitivities of water heating energy and water use efficiency to variations of climate, load, distribution type, insulation and compact plumbing practices. Overall 124 different TRNSYS models were simulated. Of the configurations evaluated, distribution losses account for 13-29% of the total water heating energy use and water use efficiency ranges from 11-22%. The base case, an uninsulated trunk and branch system sees the most improvement in energy consumption by insulating and locating the water heater central to all fixtures. Demand recirculation systems are not projected to provide significant energy savings and in some cases increase energy consumption. Water use is most efficient with demand recirculation systems, followed by the insulated trunk and branch system with a central water heater. Compact plumbing practices and insulation have the most impact on energy consumption (2-6% for insulation and 3-4% per 10 gallons of enclosed volume reduced). The results of this work are useful in informing future development of water heating best practices guides as well as more accurate (and simulation time efficient) distribution models for annual whole house simulation programs.

  6. Optimization of hybrid-water/air-cooled condenser in an enhanced turbine geothermal ORC system

    Broader source: Energy.gov [DOE]

    DOE Geothermal Program Peer Review 2010 - Presentation. Project objective: To improve the efficiency and output variability of geothermal-based ORC power production systems with minimal water consumption by deploying: 1) a hybrid-water/air cooled condenser with low water consumption and 2) an enhanced turbine with high efficiency.

  7. Analyzing water supply in future energy systems using the TIMES Integrated Assessment Model (TIAM-FR)

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Mathematics, MINES ParisTech Sophia Antipolis, France ABSTRACT Even though policies related to water energy system model. Water footprints for the processes in terms of withdrawals and consumptions were environmental impacts. Some experts refer to water as the new oil, reflecting a growing concern about

  8. Simulation of energy use in residential water heating systems Carolyn Dianarose Schneyer

    E-Print Network [OSTI]

    Victoria, University of

    around BC: Kamloops, Victoria and Williams Lake. Electric and gas-fired tank water heaters of various The resulting data is presented from a variety of angles, including the relative impacts of water heater ratingSimulation of energy use in residential water heating systems by Carolyn Dianarose Schneyer B

  9. Alameda Municipal Power- Residential Energy Efficiency Program

    Broader source: Energy.gov [DOE]

    Alameda Municipal Power (AMP) offers a grant to help its residential customers who have electric heat weatherize homes to increase efficiency. To participate, customers must complete and send in a...

  10. 2011 Municipal Consortium Northeast Region Workshop Materials

    Broader source: Energy.gov [DOE]

    This page provides links to the presentations given at the DOE Municipal Solid-State Street Lighting Consortium Northeast Region Workshop, held in Philadelphia, May 19–20, 2011.

  11. 2011 Municipal Consortium Southwest Region Workshop Materials

    Broader source: Energy.gov [DOE]

    This page provides links to the presentations given at the DOE Municipal Solid-State Street Lighting Consortium Southwest Region Workshop, held in San Jose, California, August 25­–26, 2011.

  12. 2010 Municipal Consortium Southwest Region Workshop Materials

    Broader source: Energy.gov [DOE]

    This page provides links to the presentations given at the DOE Municipal Solid-State Street Lighting Consortium Southwest Region Workshop, held in Los Angeles on September 30, 2010.

  13. Study of the impacts of regulations affecting the acceptance of Integrated Community Energy Systems: public utility, energy facility siting and municipal franchising regulatory programs in Iowa. Preliminary background report

    SciTech Connect (OSTI)

    Feurer, D A; Weaver, C L; Gallagher, K C; Hejna, D; Rielley, K J

    1980-01-01T23:59:59.000Z

    The authority to regulate public utilities is vested generally in the Iowa State Commerce Commission. The Commission is comprised of three members appointed by the governor with the approval of two-thirds of the senate. Commissioners are appointed for six-year terms. They must be free from employment or pecuniary interests in any public utility. Although the right to grant franchises is specifically reserved for municipalities, local governments exercise no regulatory authority over the provision of utility services by public utilities. Municipally-owned utilities, however, are specifically excepted from rate regulation by the Commission. The regulation of rates charged by municipally-owned utilities is the responsibility of local governments. The Commission is given no authority to review decisions of local governments with respect to rates. Public utility regulatory statutes, energy facility siting programs, and municipal franchising authority are examined to identify how they may impact on the ability of an organization, whether or not it be a regulated utility, to construct and operate an ICES.

  14. Study of the impacts of regulations affecting the acceptance of Integrated Community Energy Systems: public utility, energy facility siting and municipal franchising regulatory programs in Ohio. Preliminary background report

    SciTech Connect (OSTI)

    Feurer, D A; Weaver, C L; Gallagher, K C; Hejna, D; Rielley, K J

    1980-01-01T23:59:59.000Z

    The Public Utilities Commission (PUCO) is a body created by the Ohio State legislature to administer the provisions of the Ohio Public Utilities Act. It is composed of three commissioners appointed by the governor with the advice and consent of the senate. Once appointed, a commissioner serves for a six-year period. The PUCO is vested with the power and jurisdiction to supervise and regulate public utilities and railroads... . The term public utility includes every corporation, company, co-partnership, person or association, their lessees, trustees, or receivers, as defined in the Ohio Code. Among the various services enumerated in the Code under the definition of public utility are an electric light company; a gas company; a pipeline company transporting gas, oil or coal; a waterworks company; a heating or cooling company. The power to regulate public utilities is shared by the PUCO and municipal governments. The municipal regulatory authority is derived from the Ohio Constitution, statutory provisions, and municipal franchising authority. Public utility regulatory statutes, energy facility siting programs, and municipal franchising authority are examined to identify how they may impact on the ability of an organization, whether or not it be a regulated utility, to construct and operate an ICES.

  15. A range of soil amendments including diammonium phosphate fertilizer (DAP), municipal biosolids (BS), biosolids

    E-Print Network [OSTI]

    Brown, Sally

    biosolids (BS), biosolids compost, and Al- and Fe-based water treatment residuals were tested on Pb-, Zn for the first season, with the highest growth in the treatments that included compost and biosolids). Application of municipal biosolids in combination with a lime source has also been shown to reduce th

  16. MODIFIED REVERSE OSMOSIS SYSTEM FOR TREATMENT OF PRODUCED WATERS

    SciTech Connect (OSTI)

    T.M. Whitworth; Liangxiong Li

    2002-09-15T23:59:59.000Z

    This report describes work performed during the first year of the project ''Modified Reverse Osmosis System for Treatment of Produced Waters.'' This research project has two objectives. The first objective is to test the use of clay membranes in the treatment of produced waters by reverse osmosis. The second objective is to test the ability of a system patented by the New Mexico Tech Research Foundation to remove salts from reverse osmosis waste streams as a solid. We performed 12 experiments using clay membranes in cross-flow experimental cells. We found that, due to dispersion in the porous frit used adjacent to the membrane, the concentration polarization layer seems to be completely (or nearly completely) destroyed at low flow rates. This observation suggests that clay membranes used with porous frit material many reach optimum rejection rates at lower pumping rates than required for use with synthetic membranes. The solute rejection efficiency decreases with increasing solution concentration. For the membranes and experiments reported here, the rejection efficiency ranged from 71% with 0.01 M NaCl solution down to 12% with 2.3 M NaCl solution. More compacted clay membranes will have higher rejection capabilities. The clay membranes used in our experiments were relatively thick (approximately 0.5 mm). The active layer of most synthetic membranes is only 0.04 {micro}m (0.00004 mm), approximately 1250 times thinner than the clay membranes used in these experiments. Yet clay membranes as thin as 12 {micro}m have been constructed (Fritz and Eady, 1985). Since Darcy's law states that the flow through a material of constant permeability is inversely proportional to it's the material's thickness, then, based on these experimental observations, a very thin clay membrane would be expected to have much higher flow rates than the ones used in these experiments. Future experiments will focus on testing very thin clay membranes. The membranes generally exhibited reasonable stable rejection rates over time for chloride for a range of concentrations between 0.01 and 2.5 M. One membrane ran in excess of three months with no apparent loss of usability. This suggests that clay membranes may have a long useable life. Twenty different hyperfiltration-induced solute precipitation experiments were either attempted or completed and are reported here. The results of these experiments suggest that hyperfiltration-induced solute precipitation is possible, even for very soluble substances such as NaCl. However, the precipitation rates obtained in the laboratory do not appear to be adequate for commercial application at this time. Future experiments will focus on making the clay membranes more compact and thinner in order to obtain higher flux rates. Two alternative methods of removing solutes from solution, for which the New Mexico Tech Research Foundation is preparing patent applications, are also being investigated. These methods will be described in the next annual report after the patent applications are filed. Technology transfer efforts included two meetings (one in Farmington NM, and one in Hobbs, NM) where the results of this research were presented to independent oil producers and other interested parties. In addition, members of the research team gave seven presentations concerning this research and because of this research project T. M. (Mike) Whitworth was asked to sit on the advisory board for development of a new water treatment facility for the City of El Paso, Texas. Several papers are in preparation for submission to peer-reviewed journals based on the data presented in this report.

  17. Experimental results of water film formation on various fuel forms from a fire suppression system

    SciTech Connect (OSTI)

    Ross, R.H.; Davis, J.R.

    1994-12-31T23:59:59.000Z

    The purpose of the study was to determine the thickness and coverage of water film formations on various materials during fire sprinkler deluge. The primary criticality safety concern with automatic fire suppression systems is the increased amount of water that a film adds to the interstitial volume of an array per unit time. An exhaustive literature search revealed that no applicable research data exist that govern water film formations from fire protection systems. Therefore, a controlled, infield, mockup was created to predict the thickness and coverage of water film on fissile material forms. This paper discusses the background, experimental procedure, and the characterization of these water films.

  18. Watts nickel and rinse water recovery via an advanced reverse osmosis system

    SciTech Connect (OSTI)

    Schmidt, C.; White, I.E.; Ludwig, R.

    1993-08-01T23:59:59.000Z

    The report summarizes the results of an eight month test program conducted at the Hewlett Packard Printed Circuit Board Production Plant, Sunnyvale, CA (H.P.) to assess the effectiveness of an advanced reverse osmosis system (AROS). The AROS unit, manufactured by Water Technologies, Inc. (WTI) of Minneapolis, MN, incorporates membrane materials and system components designed to treat metal plating rinse water and produce two product streams; (1) a concentrated metal solution suitable for the plating bath, and (2) rinse water suitable for reuse as final rinse. Waste water discharge can be virtually eliminated and significant reductions realized in the need for new plating bath solution and rinse water.

  19. Experimental analysis of municipal solid waste samples

    E-Print Network [OSTI]

    Mendoza Sanchez, Itza

    2002-01-01T23:59:59.000Z

    EXPERIMENTAL ANALYSIS OF MUNICIPAL SOLID WASTE SAMPLES A Thesis by ITZA MENDOZA SANCHEZ Submitted to the Office of Graduate Studies of Texas ASM University tn partial fulfillment of the requirements for the degree of MASTER OF SCIENCE May... 2002 Major Subject: Civil Engmeering EXPERIMENTAL ANALYSIS OF MUNICIPAL SOLID WASTE SAMPLES A Thesis by ITZA MENDOZA SANCHEZ Submitted to the Office of Graduate Studies of Texas A&M Umversity in partial fulfillment of the requirements...

  20. Soil Management Plan For The Potable Water System Upgrades Project

    SciTech Connect (OSTI)

    Field, S. M.

    2007-04-01T23:59:59.000Z

    This plan describes and applies to the handling and management of soils excavated in support of the Y-12 Potable Water Systems Upgrades (PWSU) Project. The plan is specific to the PWSU Project and is intended as a working document that provides guidance consistent with the 'Soil Management Plan for the Oak Ridge Y-12 National Security Complex' (Y/SUB/92-28B99923C-Y05) and the 'Record of Decision for Phase II Interim Remedial Actions for Contaminated Soils and Scrapyard in Upper East Fork Popular Creek, Oak Ridge, Tennessee' (DOE/OR/01-2229&D2). The purpose of this plan is to prevent and/or limit the spread of contamination when moving soil within the Y-12 complex. The major feature of the soil management plan is the decision tree. The intent of the decision tree is to provide step-by-step guidance for the handling and management of soil from excavation of soil through final disposition. The decision tree provides a framework of decisions and actions to facilitate Y-12 or subcontractor decisions on the reuse of excavated soil on site and whether excavated soil can be reused on site or managed as waste. Soil characterization results from soil sampling in support of the project are also presented.

  1. Experimental results of water film formation on various fuel forms from a fire suppression system

    SciTech Connect (OSTI)

    Ross, R.H.; Davis, J.R.

    1993-12-31T23:59:59.000Z

    The purpose of the study was to determine the thickness and coverage of water film formations on various materials during fire sprinkler deluge. An exhaustive literature search revealed that no applicable research data exists that governs water film formations from fire protection systems. Therefore, a controlled, infield, mockup was created to predict the thickness and coverage of water film on fissile material forms. This paper discusses the background, experimental procedure and the characterization of these water films.

  2. Heat Transfer Performance and Piping Strategy Study for Chilled Water Systems at Low Cooling Loads

    E-Print Network [OSTI]

    Li, Nanxi 1986-

    2012-12-05T23:59:59.000Z

    Cooling Coil Efficiency Water viscosity at the water bulk temperature Water fluid viscosity at the pipe wall temperature Fin Pitch ix TABLE OF CONTENTS... of the analysis will be compared with the weather data and chilled water system data of the DFW Airport during 2010. Other possible causes of the reduced delta-T at low loads exist and will be investigated. 8 2 LITERATURE REVIEW 2.1 Heat transfer...

  3. ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM

    E-Print Network [OSTI]

    Krieg, B.

    2010-01-01T23:59:59.000Z

    Water Projects Generating Plants and Shiftable Generationfrom "base load" generating plants. ing" and saves energy.Cily flow PUfflj);ng - GeneratIng Plant San LUIS Reservo,,'

  4. Passive decay heat removal system for water-cooled nuclear reactors

    DOE Patents [OSTI]

    Forsberg, Charles W. (Oak Ridge, TN)

    1991-01-01T23:59:59.000Z

    A passive decay-heat removal system for a water-cooled nuclear reactor employs a closed heat transfer loop having heat-exchanging coils inside an open-topped, insulated box located inside the reactor vessel, below its normal water level, in communication with a condenser located outside of containment and exposed to the atmosphere. The heat transfer loop is located such that the evaporator is in a position where, when the water level drops in the reactor, it will become exposed to steam. Vapor produced in the evaporator passes upward to the condenser above the normal water level. In operation, condensation in the condenser removes heat from the system, and the condensed liquid is returned to the evaporator. The system is disposed such that during normal reactor operations where the water level is at its usual position, very little heat will be removed from the system, but during emergency, low water level conditions, substantial amounts of decay heat will be removed.

  5. MODIFIED REVERSE OSMOSIS SYSTEM FOR TREATMENT OF PRODUCED WATERS

    SciTech Connect (OSTI)

    Robert L. Lee; Junghan Dong

    2004-06-03T23:59:59.000Z

    This final report of ''Modified Reverse Osmosis System for Treatment of Produced Water,'' DOE project No. DE-FC26-00BC15326 describes work performed in the third year of the project. Several good results were obtained, which are documented in this report. The compacted bentonite membranes were replaced by supported bentonite membranes, which exhibited the same salt rejection capability. Unfortunately, it also inherited the clay expansion problem due to water invasion into the interlayer spaces of the compacted bentonite membranes. We noted that the supported bentonite membrane developed in the project was the first of its kind reported in the literature. An {alpha}-alumina-supported MFI-type zeolite membrane synthesized by in-situ crystallization was fabricated and tested. Unlike the bentonite clay membranes, the zeolite membranes maintained stability and high salt rejection rate even for a highly saline solution. Actual produced brines from gas and oil fields were then tested. For gas fields producing brine, the 18,300 ppm TDS (total dissolved solids) in the produced brine was reduced to 3060 ppm, an 83.3% rejection rate of 15,240 ppm salt rejection. For oilfield brine, while the TDS was reduced from 181,600 ppm to 148,900 ppm, an 18% rejection rate of 32,700 ppm reduction, the zeolite membrane was stable. Preliminary results show the dissolved organics, mainly hydrocarbons, did not affect the salt rejection. However, the rejection of organics was inconclusive at this point. Finally, the by-product of this project, the {alpha}-alumina-supported Pt-Co/Na Y catalytic zeolite membrane was developed and demonstrated for overcoming the two-step limitation of nonoxidation methane (CH{sub 4}) conversion to higher hydrocarbons (C{sub 2+}) and hydrogen (H{sub 2}). Detailed experiments to obtain quantitative results of H{sub 2} generation for various conditions are now being conducted. Technology transfer efforts included five manuscripts submitted to peer-reviewed journals and five conference presentations.

  6. The impact of passive safety systems on desirability of advanced light water reactors

    E-Print Network [OSTI]

    Eul, Ryan C

    2006-01-01T23:59:59.000Z

    This work investigates whether the advanced light water reactor designs with passive safety systems are more desirable than advanced reactor designs with active safety systems from the point of view of uncertainty in the ...

  7. Conservation of Energy Through The Use of a Predictive Performance Simulator of Operating Cooling Water Systems

    E-Print Network [OSTI]

    Schell, C. J.

    1981-01-01T23:59:59.000Z

    chemical treatment program for the prevention of corrosion, scale and deposit accumulations. Calgon has made available a computerized performance simulator of operating cooling water systems which reliably predicts system corrosion rates, percent scale...

  8. Water Distribution System Monitoring and Decision Support Using a Wireless Sensor Network

    E-Print Network [OSTI]

    Allen, Michael

    Water distribution systems comprise labyrinthine networks of pipes, often in poor states of repair, that are buried beneath our city streets and relatively inaccessible. Engineers who manage these systems need reliable ...

  9. Observations of englacial water passages: a fracture-dominated system

    E-Print Network [OSTI]

    Jacobel, Robert W.

    hydraulics of glaciers have focused on the subglacial regime. In temperate alpine glaciers and ice caps controls the spatial distribution of water at the bed, which may affect local ice movement. These passages and the outward melting of the ice walls due to the frictional heat produced by the flowing water. The processes

  10. VULNERABILITY ASSESSMENT OF WATER RESOURCES SYSTEMS IN THE EASTERN NILE BASIN

    E-Print Network [OSTI]

    Richner, Heinz

    VULNERABILITY ASSESSMENT OF WATER RESOURCES SYSTEMS IN THE EASTERN NILE BASIN TO ENVIRONMENTAL Resources VULNERABILITY ASSESSMENT OF WATER RESOURCES SYSTEMS IN THE EASTERN NILE BASIN TO ENVIRONMENTAL Resources Institute of African Research and Studies, Cairo University For the Degree of MASTER OF SCIENCE

  11. Side-by-Side Testing of Water Heating Systems: Results from the 2009-2010 Evaluation

    Broader source: Energy.gov [DOE]

    The performance of seven differing types of residential water heating systems was compared in a side-by-side test configuration over a full year period. The Hot Water System Laboratory (HWS Lab) test facility at the Florida Solar Energy Center (FSEC) in Cocoa, FL was used for the tests.

  12. Analysis of Heating Systems and Scale of Natural Gas-Condensing Water Boilers in Northern Zones

    E-Print Network [OSTI]

    Wu, Y.; Wang, S.; Pan, S.; Shi, Y.

    2006-01-01T23:59:59.000Z

    In this paper, various heating systems and scale of the natural gas-condensing water boiler in northern zones are discussed, based on a technical-economic analysis of the heating systems of natural gas condensing water boilers in northern zones...

  13. Analysis of Heating Systems and Scale of Natural Gas-Condensing Water Boilers in Northern Zones 

    E-Print Network [OSTI]

    Wu, Y.; Wang, S.; Pan, S.; Shi, Y.

    2006-01-01T23:59:59.000Z

    In this paper, various heating systems and scale of the natural gas-condensing water boiler in northern zones are discussed, based on a technical-economic analysis of the heating systems of natural gas condensing water boilers in northern zones...

  14. Ternary Oil-Water-Amphiphile Systems: Self-Assembly and Phase Equilibria

    E-Print Network [OSTI]

    Ternary Oil-Water-Amphiphile Systems: Self-Assembly and Phase Equilibria Seung-Yeon Kim surfactant - oil - water systems were studied by grand-canonical Monte Carlo simulations assisted H represents hydrophilic and T hydrophobic groups. In contrast to earlier studies, we studied oil

  15. Considerations for understanding one`s cooling system prior to reuse water implementation

    SciTech Connect (OSTI)

    Chmelovski, M.J. [Nalco Chemical Co., Naperville, IL (United States)

    1996-10-01T23:59:59.000Z

    Water reuse situations are growing due to the need or desire to minimize water discharge from an industrial facility. Most of these applications are retrofits or system redesigns. Many times information is required to make decisions about the reuse application. Real-time or diagnostic studies provide improved information about the water systems. Addition of very low concentrations of a chemical tracer can provide improved information about the system. Useful and unique functions of chemical tracers are that they can provide one with the following information: system volume, quantifying previously unaccounted blowdown, holding time index, water distribution, leakage, and flowrate. These are important parameters when considering water reuse and system redesign. The chemical tracers discussed in this paper represent a significant improvement over compounds previously used in reuse applications.

  16. Municipal Solid WasteMunicipal Solid Waste Landfills In CitiesLandfills In Cities

    E-Print Network [OSTI]

    Columbia University

    Municipal Solid WasteMunicipal Solid Waste Landfills In CitiesLandfills In Cities Arun to minimize public health and environmental impacts. Landfilling is the process by which residual solid waste is placed in a landfill. #12;Case in Supreme Court · Pathetic condition of Solid waste practices in India

  17. Vapor-liquid equilibria of the water + 1,3-propanediol and water + 1,3-propanediol + lithium bromide systems

    SciTech Connect (OSTI)

    Mun, S.Y.; Lee, H.

    1999-12-01T23:59:59.000Z

    Vapor-liquid equilibrium data of the water + 1,3-propanediol and water + 1,3-propanediol + lithium bromide systems were measured at 60, 160, 300, and 760 mmHg at temperatures ranging from 315 to 488 K. The apparatus used in this work is a modified still especially designed for the measurement of low-pressure VLE, in which both liquid and vapor are continuously recirculated. For the analysis of salt-containing solutions, a method incorporating refractometry and gravimetry was used. From the experimental measurements, the effect of lithium bromide on the VLE behavior of water + 1,3-propanediol was investigated. The experimental data of the salt-free system were successfully correlated using the Wilson, NRTL, and UNIQUAC models. In addition, the extended UNIQUAC model of Sander et al. was applied to the VLE calculation of salt-containing mixtures.

  18. Spent nuclear fuel project cold vacuum drying facility tempered water and tempered water cooling system design description

    SciTech Connect (OSTI)

    IRWIN, J.J.

    1998-11-30T23:59:59.000Z

    This document provides the System Design Description (SDD) for the Cold Vacuum Drying Facility (CVDF) Tempered Water (TW) and Tempered Water Cooling (TWC) System . The SDD was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems (Garvin 1998), The HNF-SD-SNF-DRD-O02, 1998, Cold Vacuum Drying Facility Design Requirements, and the CVDF Design Summary Report. The SDD contains general descriptions of the TW and TWC equipment, the system functions, requirements and interfaces. The SDD provides references for design and fabrication details, operation sequences and maintenance. This SOD has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

  19. The Potential of Cellulosic Ethanol Production from Municipal Solid Waste: A Technical and Economic Evaluation

    E-Print Network [OSTI]

    Shi, Jian; Ebrik, Mirvat; Yang, Bin; Wyman, Charles E.

    2009-01-01T23:59:59.000Z

    1996 19950414. Municipal solid waste processing facility andconversion of municipal-solid-waste to ethanol. Biotechnol.Bioconversion of municipal solid waste to glucose for bio-

  20. Pilot Phase of a Field Study to Determine Waste of Water and Energy in Residential Hot-Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    and monitoring at the water heater and hot water end uses.water at the trunk (water heater) and twigs (individual end-and outlet of the water heater and several hot water end-

  1. Water balance report for the Oak Ridge Y-12 Plant

    SciTech Connect (OSTI)

    NONE

    1994-07-01T23:59:59.000Z

    The Y-12 Plant, which occupies approximately 800 acres, was built by the Army Corps of Engineers in 1943 as part of the Manhattan Project in Oak Ridge, Tennessee. Recently, Martin Marietta Energy Systems, who manages the Y-12 Plant, has been concerned with the effects of water consumption and losses at the plant facility, and the ability of ground water beneath the site to act as a source of water seepage into East Fork Poplar Creek or as a source of water infiltration into subsurface strata. This has prompted the need to perform a water balance study on the facility. Data regarding all uses of municipal water and sources of discharge from the plant were recorded and then water balance calculations were performed using a computer model developed in a multi-dimensional electronic spreadsheet. This report describes the results of this research and includes the flow data collected during the study.

  2. A Systems-Integration Approach to the Optimal Design and Operation of Macroscopic Water Desalination and Supply Networks 

    E-Print Network [OSTI]

    Atilhan, Selma

    2012-02-14T23:59:59.000Z

    With the escalating levels of water demand, there is a need for expansion in the capacity of water desalination infrastructure and for better management and distribution of water resources. This dissertation introduces a systems approach...

  3. A Systems-Integration Approach to the Optimal Design and Operation of Macroscopic Water Desalination and Supply Networks

    E-Print Network [OSTI]

    Atilhan, Selma

    2012-02-14T23:59:59.000Z

    With the escalating levels of water demand, there is a need for expansion in the capacity of water desalination infrastructure and for better management and distribution of water resources. This dissertation introduces a systems approach...

  4. On-line hydraulic state prediction for water distribution systems

    E-Print Network [OSTI]

    Whittle, Andrew

    This paper describes and demonstrates a method for on?line hydraulic state prediction in urban water networks. The proposed method uses a Predictor?Corrector (PC) approach in which a statistical data?driven algorithm is ...

  5. A computerized storage and retrieval system for water quality data

    E-Print Network [OSTI]

    Sparr, Ted M

    1969-01-01T23:59:59.000Z

    and retrieval capability is needed in the field of water quality research, With many varied environmen- tal quality studies being conducted, an easy-to-use, flexible, and responsive means of storing and selectively retrieving date using a wide variety... this need, will have the follpw- Ing data management capabilities: (I) Create and maintain a water quality data base including sampled data values, reliability indicators, and remarks (2) retrieve selected data from this data bank (3} support a...

  6. Onsite Wastewater Treatment Systems: Graywater Use and Water Quality

    E-Print Network [OSTI]

    Lesikar, Bruce J.; Mechell, Justin; Alexander, Rachel

    2008-08-28T23:59:59.000Z

    : To reuse graywater, a homeowner first must decide which graywater sources to collect. Us- ing graywater from all sources will increase the risk of pollutants in the graywater. Before using graywater, evaluate what it is to be used for and what... using it to water plants that thrive in acidic soils. To prevent salt accumulation, ? distribute graywater over a large surface area and rotate distribu- tion from one area to another. Select reuse applications appro- ? priate for the amount of water...

  7. Study of the impacts of regulations affecting the acceptance of Integrated Community Energy Systems: public utility, energy facility siting and municipal franchising regulatory programs in Missouri. Preliminary background report

    SciTech Connect (OSTI)

    Feurer, D A; Weaver, C L; Gallagher, K C; Hejna, D; Rielley, K J

    1980-01-01T23:59:59.000Z

    The authority to regulate public utilities in Missouri is vested in the Public Service Commission. The Commission is composed of five members who are appointed by the governor with the advice and consent of the senate. Commissioners are appointed for a term of six years. Commissioners must be free from any employment or pecuniary interests incompatible with the duties of the Commission. The Commission is charged with the general supervision of public utilities. The Public Service Commission Law passed in 1913, makes no provision for the regulation of public utilities by municipalities. Public utility regulatory statutes, energy facility siting programs, and municipal franchising authority are examined to identify how they may impact on the ability of an organization, whether or not it be a regulated utility, to construct and operate an ICES.

  8. Reining in drought : how water limits influence conservation in Massachusetts towns

    E-Print Network [OSTI]

    Brown, Anna L. (Anna Libby)

    2006-01-01T23:59:59.000Z

    It's surprising to learn that the water-rich state of Massachusetts experiences incidences of water stress, where rivers go dry for stretches of the year and where municipalities struggle to meet water demand. Water ...

  9. Robust feasibility for control of water flow in a reservoir-canal system

    E-Print Network [OSTI]

    . INTRODUCTION Open-channel hydraulic systems are central to a variety of human needs such as irrigation, power of irrigation systems has be- come a crucial issue. Historically, irrigation systems around the world wereRobust feasibility for control of water flow in a reservoir-canal system Saurabh Amin, Alexandre M

  10. Water Use in Enhanced Geothermal Systems (EGS): Geology of U.S. Stimulation Projects, Water Costs, and Alternative Water Use Policies

    SciTech Connect (OSTI)

    Schroeder, Jenna N.

    2014-12-16T23:59:59.000Z

    According to the Energy Information Administration (EIA) of the U.S. Department of Energy (DOE), geothermal energy generation in the United States is projected to more than triple by 2040 (EIA 2013). This addition, which translates to more than 5 GW of generation capacity, is anticipated because of technological advances and an increase in available sources through the continued development of enhanced geothermal systems (EGSs) and low-temperature resources (EIA 2013). Studies have shown that air emissions, water consumption, and land use for geothermal electricity generation have less of an impact than traditional fossil fuel?based electricity generation; however, the long-term sustainability of geothermal power plants can be affected by insufficient replacement of aboveground or belowground operational fluid losses resulting from normal operations (Schroeder et al. 2014). Thus, access to water is therefore critical for increased deployment of EGS technologies and, therefore, growth of the geothermal sector. This paper examines water issues relating to EGS development from a variety of perspectives. It starts by exploring the relationship between EGS site geology, stimulation protocols, and below ground water loss, which is one of the largest drivers of water consumption for EGS projects. It then examines the relative costs of different potential traditional and alternative water sources for EGS. Finally it summarizes specific state policies relevant to the use of alternative water sources for EGS, and finally explores the relationship between EGS site geology, stimulation protocols, and below ground water loss, which is one of the largest drivers of water consumption for EGS projects.

  11. Water Use in Enhanced Geothermal Systems (EGS): Geology of U.S. Stimulation Projects, Water Costs, and Alternative Water Use Policies

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Schroeder, Jenna N.

    According to the Energy Information Administration (EIA) of the U.S. Department of Energy (DOE), geothermal energy generation in the United States is projected to more than triple by 2040 (EIA 2013). This addition, which translates to more than 5 GW of generation capacity, is anticipated because of technological advances and an increase in available sources through the continued development of enhanced geothermal systems (EGSs) and low-temperature resources (EIA 2013). Studies have shown that air emissions, water consumption, and land use for geothermal electricity generation have less of an impact than traditional fossil fuel?based electricity generation; however, the long-term sustainability of geothermal power plants can be affected by insufficient replacement of aboveground or belowground operational fluid losses resulting from normal operations (Schroeder et al. 2014). Thus, access to water is therefore critical for increased deployment of EGS technologies and, therefore, growth of the geothermal sector. This paper examines water issues relating to EGS development from a variety of perspectives. It starts by exploring the relationship between EGS site geology, stimulation protocols, and below ground water loss, which is one of the largest drivers of water consumption for EGS projects. It then examines the relative costs of different potential traditional and alternative water sources for EGS. Finally it summarizes specific state policies relevant to the use of alternative water sources for EGS, and finally explores the relationship between EGS site geology, stimulation protocols, and below ground water loss, which is one of the largest drivers of water consumption for EGS projects.

  12. Study of the impacts of regulations affecting the acceptance of Integrated Community Energy Systems: public utility, energy facility siting and municipal franchising regulatory programs in Massachusetts. Preliminary background report

    SciTech Connect (OSTI)

    Feurer, D A; Weaver, C L; Gallagher, K C; Hejna, D; Rielley, K J

    1980-01-01T23:59:59.000Z

    The authority to regulate public utilities is vested generally in the Department of Public Utilities. The Department is under the supervision and control of a commission consisting of three members appointed by the governor for terms of four years. No more than two of the commissioners may be members of the same political party. Commissioners must be freee from any employment or financial interests which are incompatible with the duties of the Department. The Department is responsible for regulating public utilities. The Department is specifically granted general supervisory authority over all gas and electric companies. Specific provisions for the appeal of local decisions exist only in the case of a municipality's approval or disapproval of new operaions by an electric or gas company in a municipality already being served by another such utility. Public utility regulatory statutes, energy facility siting programs, and municipal franchising authority are examined to identify how they may impact on the ability of an organization, whether or not it be a regulated utility, to construct and operate an ICES.

  13. Study of the impacts of regulations affecting the acceptance of Integrated Community Energy Systems: public utility, energy facility siting and municipal franchising regulatory programs in South Carolina. Preliminary background report

    SciTech Connect (OSTI)

    Feurer, D A; Weaver, C L; Gallagher, K C; Hejna, D; Rielley, K J

    1980-01-01T23:59:59.000Z

    Pursuant to constitutional South Carolina mandate the General Assembly has created the Public Service Commission. The Commission is composed of seven members elected to four year terms by the General Assembly. One commissioner is elected from each of seven districts corresponding to the congressional districts as they existed as of January 1, 1930. The commissioners elect one of their members as chairman. The South Carolina statutes contain separate chapters dealing with the regulation of public utilities and electric utilities. Public utility includes the furnishing of gas or heat (other than by means of electricity) to the public. While the Commission is granted general supervisory and regulatory powers over public utilities and electric utilities, total governments retain some control over electrical utilities. All municipality's have the power to grant exclusive franchises to such utilities for the furnishing of light to the municipality and its inhabitants. Public utility regulatory statutes, energy facility siting programs, and municipal franchising authority are examined to identify how they may impact on the ability of an organization, whether or not it be a regulated utility, to construct and operate an ICES.

  14. COSTS OF WATER TREATMENT DUE TO DIMINISHED WATER QUALITY: A CASE STUDY IN TEXAS

    E-Print Network [OSTI]

    McCarl, Bruce A.

    COSTS OF WATER TREATMENT DUE TO DIMINISHED WATER QUALITY: A CASE STUDY IN TEXAS David Dearmont Resources Research, 34(4), 849-854, 1998. #12;2 CHEMICAL COSTS OF WATER TREATMENT DUE TO DIMINISHED WATER QUALITY: A CASE STUDY IN TEXAS Abstract The cost of municipal water treatment due to diminished water

  15. Water Management Best Practices

    E-Print Network [OSTI]

    Hoffman, W.

    2011-01-01T23:59:59.000Z

    and Energy Star Programs ? www.epa.gov/watersense www.energystar.gov ? Conserve Florida Water Clearinghouse ? http://www.conservefloridawater.org/ ? Arizona Department of Water Resources ? www.azwater.gov/conservation The True Cost of Water... Future Demands Municipal Manufacturing Mining Steam Electric Agriculture New Codes & Standards Green Certification& Labeling Programs ? Green Restaurants, Hotels, etc. ? Green Guide for Health Care ? LEED ? GBI ? EPA Water Sense ? EPA...

  16. Interactions of woody biofuel feedstock production systems with water resources: Considerations for sustainability.

    SciTech Connect (OSTI)

    Trettin, Carl,C.; Amatya, Devendra; Coleman, Mark.

    2008-07-01T23:59:59.000Z

    Abstract. Water resources are important for the production of woody biofuel feedstocks. It is necessary to ensure that production systems do not adversely affect the quantity or quality of surface and ground water. The effects of woody biomass plantations on water resources are largely dependent on the prior land use and the management regime. Experience from both irrigated and non-irrigated systems has demonstrated that woody biofuel production systems do not impair water quality. Water quality actually improves from conversion of idle or degraded agricultural lands to woody biomass plantations. Site water balance may be altered by cultivation of woody biomass plantations relative to agricultural use, due to increases in evapostranspiration (ET) and storage. Incorporation of woody biomass production plantations within the landscape provides an opportunity to improve the quality of runoff water and soil conservation. Given the centrality of water resources to the sustainability of ecosystem services and other values derived, the experience with woody biofuels feedstock production systems is positive. Keywords. Short rotation woody crop, forest hydrology, water quality, hardwood plantation.

  17. Nuclear reactor with makeup water assist from residual heat removal system

    DOE Patents [OSTI]

    Corletti, M.M.; Schulz, T.L.

    1993-12-07T23:59:59.000Z

    A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit from an in-containment refueling water supply during staged depressurization leading up to passive emergency cooling by gravity feed from the refueling water storage tank, and flooding of the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and prevents flooding of the containment when such action is not necessary. Operation of the passive cooling system is not impaired. A high pressure makeup water storage tank is coupled to the reactor coolant circuit, holding makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal pumps move water from the refueling water storage tank into the coolant circuit as the coolant circuit is depressurized, preventing reaching the final depressurization stage unless the makeup coolant level continues to drop. The residual heat removal system can also be coupled in a loop with the refueling water supply tank, for an auxiliary heat removal path. 2 figures.

  18. Nuclear reactor with makeup water assist from residual heat removal system

    DOE Patents [OSTI]

    Corletti, Michael M. (New Kensington, PA); Schulz, Terry L. (Murrysville, PA)

    1993-01-01T23:59:59.000Z

    A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit from an in-containment refueling water supply during staged depressurization leading up to passive emergency cooling by gravity feed from the refueling water storage tank, and flooding of the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and prevents flooding of the containment when such action is not necessary. Operation of the passive cooling system is not impaired. A high pressure makeup water storage tank is coupled to the reactor coolant circuit, holding makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal pumps move water from the refueling water storage tank into the coolant circuit as the coolant circuit is depressurized, preventing reaching the final depressurization stage unless the makeup coolant level continues to drop. The residual heat removal system can also be coupled in a loop with the refueling water supply tank, for an auxiliary heat removal path.

  19. Heat exchanger and water tank arrangement for passive cooling system

    DOE Patents [OSTI]

    Gillett, J.E.; Johnson, F.T.; Orr, R.S.; Schulz, T.L.

    1993-11-30T23:59:59.000Z

    A water storage tank in the coolant water loop of a nuclear reactor contains a tubular heat exchanger. The heat exchanger has tube sheets mounted to the tank connections so that the tube sheets and tubes may be readily inspected and repaired. Preferably, the tubes extend from the tube sheets on a square pitch and then on a rectangular pitch there between. Also, the heat exchanger is supported by a frame so that the tank wall is not required to support all of its weight. 6 figures.

  20. The Water Purification System for the Daya Bay Reactor Neutrino Experiment

    E-Print Network [OSTI]

    J. Wilhelmi; R. Bopp; R. Brown; J. Cherwinka; J. Cummings; E. Dale; M. Diwan; J. Goett; R. W. Hackenburg; J. Kilduff; L. Littenberg; G. S. Li; X. N. Li; J. C. Liu; H. Q. Lu; J. Napolitano; C. Pearson; N. Raper; R. Rosero; P. Stoler; Q. Xiao; C. G. Yang; Y. Yang; M. Yeh

    2014-08-06T23:59:59.000Z

    We describe the design, installation, and operation of a purification system that is able to provide large volumes of high purity ASTM (D1193-91) Type-I water to a high energy physics experiment. The water environment is underground in a lightly sealed system, and this provides significant challenges to maintaining high purity in the storage pools, each of which contains several thousand cubic meters. High purity is dictated by the need for large optical absorption length, which is critical for the operation of the experiment. The system is largely successful, and the water clarity criteria are met. We also include a discussion of lessons learned.

  1. Solar heating and hot water system installed at Shoney's Restaurant, North Little Rock, Arkansas. Final report

    SciTech Connect (OSTI)

    None

    1980-08-01T23:59:59.000Z

    The solar heating system is designed to supply a major portion of the space and water heating requirements for a newly built Shoney's Big Boy Restaurant which was installed with completion occurring in December 1979. The restaurant has a floor space of approximately 4,650 square feet and requires approximately 1500 gallons of hot water daily. The solar energy system consists of 1,428 square feet of Chamberlain flat plate liquid collector subsystem, and a 1500 gallon storage subsystem circulating hot water producing 321 x 10/sup 6/ Btu/yr (specified) building heating and hot water heating. Designer - Energy Solutions, Incorporated. Contractor - Stephens Brothers, Incorporated. This report includes extracts from site files, specification references for solar modifications to existing building heating and hot water systems, drawings installation, operation and maintenance instructions.

  2. Pilot Phase of a Field Study to Determine Waste of Water and Energy in Residential Hot-Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    end use point, at the water heater in one second intervalsand monitoring at the water heater and hot water end uses.of water at the trunk (water heater) and twigs (individual

  3. Water and Energy Wasted During Residential Shower Events: Findings from a Pilot Field Study of Hot Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    of Natural Gas Tankless Water Heaters. Center for Energy andhot water from the water heater to each end-use locationMixed Temperature Water Water Heater Drain Indoor Boundary

  4. Water and Energy Wasted During Residential Shower Events: Findings from a Pilot Field Study of Hot Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    of Natural Gas Tankless Water Heaters. Center for Energy andof water at the water heater and at several end-use pointsshowerhead, entering the water heater and leaving the water

  5. Water Quality Monitoring Program In the Mill Creek System, 2008

    E-Print Network [OSTI]

    Boynton, Walter R.

    during 2008. 22 Figure 4.2.A&B Bar graphs showing (A) Patuxent River mean winter-spring flow (January Patterns and River Flow 21 4.1.Precipitation 21 4.2. River Flow 23 5. Long Term Water Quality Trends 24 5

  6. The dielectric properties of polymer-water systems

    E-Print Network [OSTI]

    Lewis, Joe Bill

    1976-01-01T23:59:59.000Z

    of methylcellulose polymer-water interacti ons". He received a Master of Science degree in 1976. Mr. Lewis is married to Anita Kaye Lewis and they have two children, ". coda Ai 1 ene and Rebecca Jo. His permanent mailing address is B;3 Mestern, Angleton, Texas...

  7. Designing a 'Near Optimum' Cooling-Water System

    E-Print Network [OSTI]

    Crozier, R. A., Jr.

    1981-01-01T23:59:59.000Z

    Cooling water is expensive to circulate. Reducing its flow - i.e., hiking exchanger outlet temperatures - can cut tower, pump and piping investment as much as one-third and operating cost almost in half. Heat-exchanger-network optimization has been...

  8. Micropolis: A Virtual City for Water Distribution System Research Applications

    E-Print Network [OSTI]

    Torres, Jacob

    2006-07-11T23:59:59.000Z

    of contaminant spread are presented, and future applications will include fire flow and water auditing. The data digital files describing Micropolis are available from the authors for others’ use. It is hoped that other virtual cities will follow for the use...

  9. Water Usage for In-Situ Oil Shale Retorting – A Systems Dynamics Model

    SciTech Connect (OSTI)

    Earl D. Mattson; Larry Hull; Kara Cafferty

    2012-12-01T23:59:59.000Z

    A system dynamic model was construction to evaluate the water balance for in-situ oil shale conversion. The model is based on a systems dynamics approach and uses the Powersim Studio 9™ software package. Three phases of an insitu retort were consider; a construction phase primarily accounts for water needed for drilling and water produced during dewatering, an operation phase includes the production of water from the retorting process, and a remediation phase water to remove heat and solutes from the subsurface as well as return the ground surface to its natural state. Throughout these three phases, the water is consumed and produced. Consumption is account for through the drill process, dust control, returning the ground water to its initial level and make up water losses during the remedial flushing of the retort zone. Production of water is through the dewatering of the retort zone, and during chemical pyrolysis reaction of the kerogen conversion. The major water consumption was during the remediation of the insitu retorting zone.

  10. Georgia: Data Center and Historic Municipal Building Go Green...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Municipal Building Go Green Georgia: Data Center and Historic Municipal Building Go Green August 21, 2013 - 9:45am Addthis Data centers can consume 100 to 200 times more...

  11. Saint Peter Municipal Utilities- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Southern Minnesota Municipal Power Agency ([http://www.smmpa.com SMMPA]) is a joint-action agency which generates and sells reliable electricity at wholesale to its eighteen non-profit, municipally...

  12. Mora Municipal Utilities- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Southern Minnesota Municipal Power Agency ([http://www.smmpa.com SMMPA]) is a joint-action agency which generates and sells reliable electricity at wholesale to its eighteen non-profit, municipally...

  13. Wastewater Regulations for National Pollutant Discharge Elimination System (NPDES) Permits, Underground Injection Control (UIC) Permits, State Permits, Water Quality Based Effluent Limitations and Water Quality Certification (Mississippi)

    Broader source: Energy.gov [DOE]

    The Wastewater Regulations for National Pollutant Discharge Elimination System (NPDES) Permits, Underground Injection Control (UIC) Permits, State Permits, Water Quality Based Effluent Limitations...

  14. Proposal for the award of a contract for the supply of water cooling systems for the HIE-ISOLDE infrastructure

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    Proposal for the award of a contract for the supply of water cooling systems for the HIE-ISOLDE infrastructure

  15. INTEGRATED CO2 HEAT PUMP SYSTEMS FOR SPACE HEATING AND HOT WATER HEATING IN LOW-ENERGY HOUSES AND

    E-Print Network [OSTI]

    J. Stene

    designed as stand-alone systems, i.e. a heat pump water heater (HPWH) in combination with separate units

  16. The effects of the implementation of grey water reuse systems on construction cost and project schedule

    E-Print Network [OSTI]

    Kaduvinal Varghese, Jeslin

    2009-05-15T23:59:59.000Z

    of the United States due to their effects on construction cost and project schedules. Even though a project could get one or multiple points upon successful implementation of a grey water reuse system and conserving potable water, the following factors may have...

  17. Dynamics and solutions to some control problems for water-tank systems

    E-Print Network [OSTI]

    1 Dynamics and solutions to some control problems for water-tank systems Nicolas Petit , Pierre translations and rotations. The fluid motion is described by linearized wave equations under shallow water describe the lack of approximate controllability. The first contribution of the paper consists of models

  18. Commissioning the Domestic Hot Water System on a Large University Campus: A Case Study

    E-Print Network [OSTI]

    Chen, H.; Bensouda, N.; Claridge, D.; Bruner, H.

    2004-01-01T23:59:59.000Z

    was to investigate the causes of these problems and help determine how to best operate the system. It was found that reported problems of low flows, low temperatures and long hot water lag time resulted from reverse flows and no hot water circulation caused by: 1...

  19. Air and water flows in a large sand box with a two-layer aquifer system

    E-Print Network [OSTI]

    Jiao, Jiu Jimmy

    Air and water flows in a large sand box with a two-layer aquifer system Xingxing Kuang & Jiu Jimmy negative air pressure can be generated in the vadose zone during pumping. The negative air pressure. The initial water-table depth has a significant effect on the generated negative air pressure. The shallower

  20. Acceptance test report for high pressure water jet system feed pump

    SciTech Connect (OSTI)

    Crystal, J.B.

    1996-03-12T23:59:59.000Z

    This document summarizes results of WHC-SD-SNF-ATP-016, Rev. 0 ``Acceptance Test Procedure High Pressure Water Jet System``, conducted on December 20, 1995 and December 22, 1995. This jet supplies water at 15,000 psi @ 15 gpm to nozzles to clean surfaces of empty fuel storage canisters.

  1. Solar PV water pumping system for rural development in Nepal: Problems and prospects

    SciTech Connect (OSTI)

    Shrestha, J.N. [Inst. of Engineering, Kathmandu (Nepal). Dept. of Electronics Engineering

    1996-12-31T23:59:59.000Z

    Although PV water pumping systems have high initial costs, they require virtually no maintenance, require no fuel and thus save foreign exchange. They are easy to install and operate, have no moving parts and hence are highly reliable and durable and are modular in nature for future expansion, PV systems are found to be competitive with conventional diesel generator systems. Despite the above mentioned facts policy makers are still not convinced that solar PV water pumping systems can support rural development. This paper gives reasons for the failures of some solar PV water pumping projects in Nepal. Development of solar electricity totaling about 800 KWp in Nepal is briefly highlighted. Basic preconditions are identified for the successful operation of solar PV water pumping systems. The findings of successful solar PV water pumping systems are highlighted with specific reference to socio-economic impacts in the rural society. Subsidy policy of the government on solar PV water pumping systems is analyzed. Development of a spontaneous market for community solar PV water pumping system is analyzed. Suggestions are given on how solar PV water pumping system can be made more affordable by village people. Typical Nepalese rural areas are found to be suitable and economical for SPVWPS. Site evaluation procedure is given. Finally, the paper indicates the important of training for the local people in installation, operation and routine maintenance to ensure the reliability of the SPVWPS. The paper emphasizes the involvement of end-users from the very beginning of planning stage of SPVWPS. Detail comparison between a SPVWPS and an equivalent diesel generator is also indicated in the paper.

  2. Energy Department Works with Sacramento Municipal Utility District...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    About Us Initiatives & Projects Energy Transition Initiative Energy Department Works with Sacramento Municipal Utility District on Renewable Electricity Generation and...

  3. Lateral Water Diffusion in an Artificial Macroporous System: Modeling and Experimental Evidence

    E-Print Network [OSTI]

    Mohanty, Binayak P.

    Lateral Water Diffusion in an Artificial Macroporous System: Modeling and Experimental Evidence P systems, lateral mass exchange between macropores and the soil matrix is generally modeled as an apparent diffusion, the system is thus characterized by a single can be determined from moment analysis of the concen

  4. Appropriate Technologies and Systems to respond to Climate Change, Improved Water Resources Management, Waste Management and Sanitation

    E-Print Network [OSTI]

    Barthelat, Francois

    Resources Management, Waste Management and Sanitation A Review of Water Information Systems in the English availability, quality, use and demand. In this regard, Water Information Systems play a key role in the management of the resource. This paper examines the water information systems of St. Lucia, Jamaica

  5. Agricultural Water Demand Along the Colorado River Main Stem

    E-Print Network [OSTI]

    Fay, Noah

    Agricultural Water Demand Along the Colorado River Main Stem: An Econometric Analysis Advisor: Dr · Agriculture is by far the largest water user in the state of Arizona (70%) Municipal Industrial Agriculture 25% 7%68% Municipal Industrial Agriculture #12;Relevance to Arizona · Irrigation along the Colorado

  6. Data summary of municipal solid waste management alternatives

    SciTech Connect (OSTI)

    Not Available

    1992-10-01T23:59:59.000Z

    Composting of municipal solid waste (MSW) is experiencing a dramatic resurgence in the US. Several factors are driving this interest in composting including landfill closures, resistance to siting of new landfills and combustion facilities, public support for recycling, and, in general, the overall costs of waste disposal. Starting with only one demonstration project operating in 1980, the total number of projects in the US has increased to sixteen by July 1991. There are approximately 100 projects in some form of planning or development. One reason some communities are sekniing composting as a waste management option is that sewage sludge and MSW can be co-composted thereby recycling a major portion of the overall municipal waste stream. In 1991, five of the operating facilities have incorporated sludge, with a number of new plants also developing systems with this capability. Generic composting technologies are described followed by a comprehensive discussion of operating facilities. Information is presented on the type of processing system, capital and operating costs, and the status of compost markets. A discussion is also included on the operational problems and challenges faced by composting facility developers and operators. Also presented are facility energy usage and a discussion of the energy implications from the use of compost as a soil and fertilizer replacement. A discussion of cost sensitivity shows how facility costs are impacted by waste handling procedures, regulations, reject disposal, and finance charges. The status of, and potential for, integrating composting into the overall waste management strategy is also discussed, including composting's contribution to municipal recycling goals, and the status of public acceptance of the technology. Finally information and research needs are summarized.

  7. Energy Comparison Between Conventional and Chilled Water Thermal Storage Air Conditioning Systems

    E-Print Network [OSTI]

    Sebzali, M.; Hussain, H. J.; Ameer, B.

    2010-01-01T23:59:59.000Z

    , encouraged by government subsidies and driven by the rapid and continual expansion in building construction, urban development, and the heavy reliance on Air Conditioning (AC) systems for the cooling of buildings. The Chilled Water Thermal Storage (CWTS...

  8. THE SYSTEM THORIUM NITRATE-WATER-NITRIC ACID AT 25 AND THE HYDRATES...

    Office of Scientific and Technical Information (OSTI)

    SYSTEM THORIUM NITRATE-WATER-NITRIC ACID AT 25 AND THE HYDRATES OF THORIUM NITRATE Re-direct Destination: times redirected to final destination ShortURL Code Published Current...

  9. Mitigation of steam generator tube rupture in a pressurized water reactor with passive safety systems

    DOE Patents [OSTI]

    McDermott, Daniel J. (Export, PA); Schrader, Kenneth J. (Penn Hills, PA); Schulz, Terry L. (Murrysville Boro, PA)

    1994-01-01T23:59:59.000Z

    The effects of steam generator tube ruptures in a pressurized water reactor are mitigated by reducing the pressure in the primary loop by diverting reactor coolant through the heat exchanger of a passive heat removal system immersed in the in containment refueling water storage tank in response to a high feed water level in the steam generator. Reactor coolant inventory is maintained by also in response to high steam generator level introducing coolant into the primary loop from core make-up tanks at the pressure in the reactor coolant system pressurizer. The high steam generator level is also used to isolate the start-up feed water system and the chemical and volume control system to prevent flooding into the steam header. 2 figures.

  10. Mitigation of steam generator tube rupture in a pressurized water reactor with passive safety systems

    DOE Patents [OSTI]

    McDermott, D.J.; Schrader, K.J.; Schulz, T.L.

    1994-05-03T23:59:59.000Z

    The effects of steam generator tube ruptures in a pressurized water reactor are mitigated by reducing the pressure in the primary loop by diverting reactor coolant through the heat exchanger of a passive heat removal system immersed in the in containment refueling water storage tank in response to a high feed water level in the steam generator. Reactor coolant inventory is maintained by also in response to high steam generator level introducing coolant into the primary loop from core make-up tanks at the pressure in the reactor coolant system pressurizer. The high steam generator level is also used to isolate the start-up feed water system and the chemical and volume control system to prevent flooding into the steam header. 2 figures.

  11. Investigation of a Novel Solar Assisted Water Heating System with Enhanced Energy Yield for Buildings

    E-Print Network [OSTI]

    Zhang, X.; Zhao, X.; Xu, J.; Yu, X.

    2012-01-01T23:59:59.000Z

    This paper presented the concept, prototype application, operational performance and benefits relating to a novel solar assisted water heating system for building services. It was undertaken through dedicated theoretical analysis, computer...

  12. Wavelet-based Burst Event Detection and Localization in Water Distribution Systems

    E-Print Network [OSTI]

    Srirangarajan, Seshan

    In this paper we present techniques for detecting and locating transient pipe burst events in water distribution systems. The proposed method uses multiscale wavelet analysis of high rate pressure data recorded to detect ...

  13. Design and Experiments of a Solar Low-temperature Hot Water Floor Radiant Heating System 

    E-Print Network [OSTI]

    Wu, Z.; Li, D.

    2006-01-01T23:59:59.000Z

    The solar low-temperature hot water floor radiant heating system combines solar energy heating with floor radiant heating. This kind of environmental heating way not only saves fossil resources and reduces pollution, but also makes people feel more...

  14. Design and Experiments of a Solar Low-temperature Hot Water Floor Radiant Heating System

    E-Print Network [OSTI]

    Wu, Z.; Li, D.

    2006-01-01T23:59:59.000Z

    The solar low-temperature hot water floor radiant heating system combines solar energy heating with floor radiant heating. This kind of environmental heating way not only saves fossil resources and reduces pollution, but also makes people feel more...

  15. Spirasol : improvements to semi-continuous solar disinfection water treatment systems

    E-Print Network [OSTI]

    Loux, Brian Michael, 1981-

    2005-01-01T23:59:59.000Z

    An experimental study was carried out to determine the feasibility of an original point of use solar water disinfection system created by the author and named "Spirasol." The study primarily focused on the comparison of ...

  16. H?Otel : a new model for integrating water systems and coastal architecture

    E-Print Network [OSTI]

    Brown, Danielle C. (Danielle Collinsworth)

    2011-01-01T23:59:59.000Z

    During the Industrial Era, "dams, water towers, sewage systems, and the like were celebrated as glorious icons, carefully designed, ornamented, and prominently located in the city, testifying to the modern promise of ...

  17. Rock-Water Interactions In Hot Dry Rock Geothermal Systems- Field...

    Open Energy Info (EERE)

    Rock-Water Interactions In Hot Dry Rock Geothermal Systems- Field Investigations Of In Situ Geochemical Behavior Jump to: navigation, search OpenEI Reference LibraryAdd to library...

  18. Effects of Biochar Recycling on Switchgrass Growth and Soil and Water Quality in Bioenergy Production Systems

    E-Print Network [OSTI]

    Husmoen, Derek Howard

    2012-07-16T23:59:59.000Z

    the logistics for recycling biochar to fields from which the biomass feedstocks are harvested. The contribution of biochar recycling from mobile pyrolysis systems to ecological services provided by agriculture, including sustained soil, water...

  19. Risk Analysis and Adaptive Response Planning for Water Distribution Systems Contamination Emergency Management

    E-Print Network [OSTI]

    Rasekh, Amin

    2012-10-19T23:59:59.000Z

    are investigated. Pressure-driven hydraulic analysis is performed to simulate the complicated system hydraulics under pressure-deficit conditions. Performance of a novel preventive response action ? injection of food-grade dye directly into drinking water...

  20. Nonlinear Model Predictive Control of Municipal Solid Waste Combustion Plants

    E-Print Network [OSTI]

    Van den Hof, Paul

    Nonlinear Model Predictive Control of Municipal Solid Waste Combustion Plants M. Leskens , R.h.Bosgra@tudelft.nl, p.m.j.vandenhof@tudelft.nl Keywords : nonlinear model predictive control, municipal solid waste combus- tion Abstract : Combustion of municipal solid waste (MSW; = household waste) is used to reduce

  1. Department of Environmental Engineering Leaching from Municipal Solid Waste

    E-Print Network [OSTI]

    Department of Environmental Engineering Leaching from Municipal Solid Waste Incineration Residues Ji í Hyk s #12;#12;Leaching from Municipal Solid Waste Incineration Residues Ji í Hyks Ph.D. Thesis Municipal Solid Waste Incineration Residues Cover: Torben Dolin & Julie Camilla Middleton Printed by: Vester

  2. Improved Economic Performance Municipal Solid Waste Combustion Plants

    E-Print Network [OSTI]

    Van den Hof, Paul

    Improved Economic Performance of Municipal Solid Waste Combustion Plants by Model Based Combustion Control #12;#12;Improved Economic Performance of Municipal Solid Waste Combustion Plants by Model Based-of-the-art and challenges in the operation of MSWC plants . . . 1 1.1.1 The aims of municipal solid waste combustion

  3. Community water systems recovering from the drought: Lessons learned; plans made 

    E-Print Network [OSTI]

    Wythe, Kathy

    2011-01-01T23:59:59.000Z

    Story by Kathy Wythe Community water systems recovering from the drought LESSONS LEARNED; PLANS MADE Summer 2012 tx H2O 7 ] An East Texas water supply reservoir was so low that water was unable to be withdrawn using the normal...;,#18;#24;#24; was about three weeks away from running out of water. With the entire state experiencing exceptional or extreme drought for most of #25;#24;#23;#23;, Groesbeck stood out as a warning to other Texas communities about what they could experience...

  4. Community water systems recovering from the drought: Lessons learned; plans made

    E-Print Network [OSTI]

    Wythe, Kathy

    2011-01-01T23:59:59.000Z

    Story by Kathy Wythe Community water systems recovering from the drought LESSONS LEARNED; PLANS MADE Summer 2012 tx H2O 7 ] An East Texas water supply reservoir was so low that water was unable to be withdrawn using the normal...;,#18;#24;#24; was about three weeks away from running out of water. With the entire state experiencing exceptional or extreme drought for most of #25;#24;#23;#23;, Groesbeck stood out as a warning to other Texas communities about what they could experience...

  5. A Guide for Using the Transient Ground-Water Flow Model of the Death Valley Regional Ground-Water Flow System, Nevada and California

    SciTech Connect (OSTI)

    Joan B. Blainey; Claudia C. Faunt, and Mary C. Hill

    2006-05-16T23:59:59.000Z

    This report is a guide for executing numerical simulations with the transient ground-water flow model of the Death Valley regional ground-water flow system, Nevada and California using the U.S. Geological Survey modular finite-difference ground-water flow model, MODFLOW-2000. Model inputs, including observations of hydraulic head, discharge, and boundary flows, are summarized. Modification of the DVRFS transient ground-water model is discussed for two common uses of the Death Valley regional ground-water flow system model: predictive pumping scenarios that extend beyond the end of the model simulation period (1998), and model simulations with only steady-state conditions.

  6. Water treatment process and system for metals removal using Saccharomyces cerevisiae

    DOE Patents [OSTI]

    Krauter, Paula A. W. (Livermore, CA); Krauter, Gordon W. (Livermore, CA)

    2002-01-01T23:59:59.000Z

    A process and a system for removal of metals from ground water or from soil by bioreducing or bioaccumulating the metals using metal tolerant microorganisms Saccharomyces cerevisiae. Saccharomyces cerevisiae is tolerant to the metals, able to bioreduce the metals to the less toxic state and to accumulate them. The process and the system is useful for removal or substantial reduction of levels of chromium, molybdenum, cobalt, zinc, nickel, calcium, strontium, mercury and copper in water.

  7. Impact of water resource development on the hydrology and sedimentology of the Brazos River system

    E-Print Network [OSTI]

    Minter, Larry Lane

    1976-01-01T23:59:59.000Z

    IMPACT OF WATER RESOURCE DEVELOPMENT ON THE HYDROLOGY AND SEDIMENTOLOGY OF THE BRAZOS RIVER SYSTEM A Thesis by Submitted to the Graduate College of Texas ALM University in partial fulfillment of the requirement for the degree of MASTER... OF SCIENCE August 1976 Major Subject: Geology IMPACT OF WATER RESOURCE DEVFLOPMENT ON THE HYDROLOGY AND SEDIMENTOLOGY OF THE BRAZOS RIVER SYSTEM A Thesis by LARRY LANE MINTER Approved as to style snd. content by: (Chairman of Committee) n (Head...

  8. Simulating the Effect of Water on the Fracture System of Shale Gas Wells

    E-Print Network [OSTI]

    Hamam, Hassan Hasan H.

    2011-10-21T23:59:59.000Z

    SIMULATING THE EFFECT OF WATER ON THE FRACTURE SYSTEM OF SHALE GAS WELLS A Thesis by HASSAN HASAN H. HAMAM Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements... for the degree of MASTER OF SCIENCE August 2010 Major Subject: Petroleum Engineering SIMULATING THE EFFECT OF WATER ON THE FRACTURE SYSTEM OF SHALE GAS WELLS A Thesis by HASSAN HASAN H. HAMAM Submitted to the Office of Graduate...

  9. An evaluation of household drinking water treatment systems in Peru : the table filter and the safe water system

    E-Print Network [OSTI]

    Coulbert, Brittany, 1981-

    2005-01-01T23:59:59.000Z

    (cont.) storage, and education. Tests on the SWSs in Peru demonstrated 99.6% E.coli removal and 95% total coliform removal. Only 30% of the SWSs tested contained water at or above the WHO-recommended concentration of free ...

  10. 25 Cologne Municipal Museum 30 Museum Ludwig

    E-Print Network [OSTI]

    Iosup, Alexandru

    TAXI TAXI TAXI TAXI TAXI TAXI TAXI TAXI TAXI H H TAXI Museums 25 Cologne Municipal Museum 30 Museum Ludwig 33 EL-DE Haus NS-Documentation Centre 34 Roman-Germanic Museum 36 Applied Arts and Crafts Museum 48 Käthe-Kollwitz Museum 52 Wallraf-Richartz-Museum 54 Museum of East-Asian Art 56 Schnütgen Museum

  11. Essays on Municipal Public Finance in Brazil

    E-Print Network [OSTI]

    Gardner, Rachel Elizabeth

    2013-01-01T23:59:59.000Z

    of Revenue Generation Infrastructure IV-2SLS Coefficient onIV-2SLS estimates indicate a null relationship between transfers and per capita revenue generation.IV-2SLS fixed effects estimates without municipality fixed effects seem to indicate 0.2 cent increase in local revenue generation

  12. QUALITY OF COMPOSTS FROM MUNICIPAL BIODEGRADABLE WASTE

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    QUALITY OF COMPOSTS FROM MUNICIPAL BIODEGRADABLE WASTE OF DIFFERENT ORIGINS I. ZDANEVITCH AND O countries. One of the outputs of this treatment is a compost prepared from the organic matter of the waste the total MSW in the plant. Unlike in Germany or Austria, where only the compost from selective collection

  13. Documentation of INL’s In Situ Oil Shale Retorting Water Usage System Dynamics Model

    SciTech Connect (OSTI)

    Earl D Mattson; Larry Hull

    2012-12-01T23:59:59.000Z

    A system dynamic model was construction to evaluate the water balance for in-situ oil shale conversion. The model is based on a systems dynamics approach and uses the Powersim Studio 9™ software package. Three phases of an in situ retort were consider; a construction phase primarily accounts for water needed for drilling and water produced during dewatering, an operation phase includes the production of water from the retorting process, and a remediation phase water to remove heat and solutes from the subsurface as well as return the ground surface to its natural state. Throughout these three phases, the water is consumed and produced. Consumption is account for through the drill process, dust control, returning the ground water to its initial level and make up water losses during the remedial flushing of the retort zone. Production of water is through the dewatering of the retort zone, and during chemical pyrolysis reaction of the kerogen conversion. The document discusses each of the three phases used in the model.

  14. Water gate array for current flow or tidal movement pneumatic harnessing system

    DOE Patents [OSTI]

    Gorlov, Alexander M. (Brookline, MA)

    1991-01-01T23:59:59.000Z

    The invention, which provides a system for harnessing power from current flow or tidal movement in a body of water, comprises first and second hydro-pneumatic chambers each having ingress and egress below the water surface near the river or ocean floor and water gates operative to open or seal the ports to the passage of water. In an exemplary embodiment, the gates are sychronized by shafts so that the ingress ports of each chamber are connected to the egress ports of each other chamber. Thus, one set of gates is closed, while the other is open, thereby allowing water to flow into one chamber and build air pressure therein and allowing water to flow out of the other chamber and create a partial vacuum therein. A pipe connects the chambers, and an air turbine harnesses the air movement within the pipe. When water levels are equilibrated, the open set of gates is closed by a counterweight, and the other set is allowed to open by natural force of the water differential. The water gates may be comprised of a plurality of louvers which are ganged for simultaneous opening and closing. The system is designed to operate with air turbines or other pneumatic devices. Its design minimizes construction cost and environmental impact, yet provides a clean renewable energy source.

  15. automated watering systems: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

  16. Energy Savings with High Temperature Water Generation Systems

    E-Print Network [OSTI]

    Manicke, A. C.

    1982-01-01T23:59:59.000Z

    maintenance and operating cost, as well as some of the unfavorable o~erating conditions common to steam systems. A few! of the items and conditions are elimination 01 steam traps, condensate return systems, return I system corros;on, deaerati ng feedwater... systems an~ thei r maintenance, elimination of b10wdown requi~ements, e1 imination of vent and f1 ash losses, a ~ubstan? tia1 reduction in feedwater makeup requi~ements, feedwater treatment equipment, and feedwater chemical additives. I...

  17. Distrbuted Sensing Systems for Water Quality Assesment and Management

    E-Print Network [OSTI]

    2007-01-01T23:59:59.000Z

    and A. Maccabe. 2004. “Radiation Detection with DistributedRennie, G. 2004. “Radiation Detection on the Front Lines. ”sensing systems for radiation detection has shown great

  18. Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

    SciTech Connect (OSTI)

    Rudd, A.

    2012-08-01T23:59:59.000Z

    This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

  19. Preoperational test report, cross-site transfer water flush system (POTP-001)

    SciTech Connect (OSTI)

    Parsons, G.L.

    1998-02-20T23:59:59.000Z

    This report documents the results of the testing performed per POTP-001, for the Cross-Site Transfer Water Flush System. (HNF-1552, Rev. 0) The Flush System consists of a 47,000 gallon tank (302C), a 20 hp pump, two 498kW heaters, a caustic addition pump, various valves, instruments, and piping. The purpose of this system is to provide flush water at 140 F, 140gpm, and pH 11-12 for the Cross-Site Transfer System operation.

  20. Recirculation of municipal landfill leachate

    E-Print Network [OSTI]

    Pinkowski, Brian Jude

    1987-01-01T23:59:59.000Z

    . Under the 1984 amendments to the Resource Conservation and Recovery Act (RCRA), land disposal of hazardous waste in new facilities cannot take place unless these three conditions are met: 1. There are no other means available for disposal, 2. Double... as it passes through the landfill and liners are used to stop the migration oF the leachate into the groundwater by acting as a barrier. Style of the Water Pollution Control Federation RCRA defines hazardous waste as "a solid waste, or combination of solid...

  1. Feasibility of geothermal heat use in the San Bernardino Municipal Wastewater Treatment Plant. Final report, September 1980-June 1981

    SciTech Connect (OSTI)

    Racine, W.C.; Larson, T.C.; Stewart, C.A.; Wessel, H.B.

    1981-06-01T23:59:59.000Z

    A system was developed for utilizing nearby low temperature geothermal energy to heat two high-rate primary anaerobic digesters at the San Bernardino Wastewater Treatment Plant. The geothermal fluid would replace the methane currently burned to fuel the digesters. A summary of the work accomplished on the feasibility study is presented. The design and operation of the facility are examined and potentially viable applications selected for additional study. Results of these investigations and system descriptions and equipment specifications for utilizing geothermal energy in the selected processes are presented. The economic analyses conducted on the six engineering design cases are discussed. The environmental setting of the project and an analysis of the environmental impacts that will result from construction and operation of the geothermal heating system are discussed. A Resource Development Plan describes the steps that the San Bernardino Municipal Water Department could follow in order to utilize the resource. A preliminary well program and rough cost estimates for the production and injection wells also are included. The Water Department is provided with a program and schedule for implementing a geothermal system to serve the wastewater treatment plant. Regulatory, financial, and legal issues that will impact the project are presented in the Appendix. An outline of a Public Awareness Program is included.

  2. Abstract: Air, Thermal and Water Management for PEM Fuel Cell Systems

    SciTech Connect (OSTI)

    Mark K. Gee

    2008-10-01T23:59:59.000Z

    PEM fuel cells are excellent candidates for transportation applications due to their high efficiencies. PEM fuel cell Balance of Plant (BOP) components, such as air, thermal, and water management sub-systems, can have a significant effect on the overall system performance, but have traditionally not been addressed in research and development efforts. Recognizing this, the U.S. Department of Energy and Honeywell International Inc. are funding an effort that emphasizes the integration and optimization of air, thermal and water management sub-systems. This effort is one of the major elements to assist the fuel cell system developers and original equipment manufacturers to achieve the goal of an affordable and efficient power system for transportation applications. Past work consisted of: (1) Analysis, design, and fabrication of a motor driven turbocompressor. (2) A systematic trade study to select the most promising water and thermal management systems from five different concepts (absorbent wheel humidifier, gas to gas membrane humidifier, porous metal foam humidifier, cathode recycle compressor, and water injection pump.) This presentation will discuss progress made in the research and development of air, water and thermal management sub-systems for PEM fuel cell systems in transportation applications. More specifically, the presentation will discuss: (1) Progress of the motor driven turbocompressor design and testing; (2) Progress of the humidification component selection and testing; and (3) Progress of the thermal management component preliminary design. The programs consist of: (1) The analysis, design, fabrication and testing of a compact motor driven turbocompressor operating on foil air bearings to provide contamination free compressed air to the fuel cell stack while recovering energy from the exhaust streams to improve system efficiency. (2) The analysis, design, fabrication and testing of selected water and thermal management systems and components to improve system efficiency and reduce packaging size.

  3. Water Rights Analysis Package (WRAP) Modeling System Users Manual

    E-Print Network [OSTI]

    Wurbs, R

    2012-10-01T23:59:59.000Z

    ...................................................... 140 Time Series Records (2NAT, 2REG, 2UNA, 2CLO, 2CLC, 2RFR, 2URR, 2CPI, 2STO, 2EVA, 2DEP, 2TAR, 2SHT, 2DIV, 2IFT, 2IFS, 2EPD, 2EVR, 2WSE) .......... 141 IDEN Record ? Identifiers for Control points, Reservoirs, Water Rights, or Groups... of all files associated with a particular simulation. The filename extension differentiates the different types of data contained in the files. ? Assigning a different root (root2 in Table 1.2) for the hydrology files (FLO, EVA, HYD, DIS, FAD) may...

  4. Water Treatment System Cleans Marcellus Shale Wastewater | Department of

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA group currentBradley Nickell DirectorThe Water Power Program, partEnergy DC -

  5. Solar Water Heating System Maintenance and Repair | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartment of EnergySite Screening Decision Tree SolarSolar Water

  6. Process modeling of hydrogen production from municipal solid waste

    SciTech Connect (OSTI)

    Thorsness, C.B.

    1995-01-01T23:59:59.000Z

    The ASPEN PLUS commercial simulation software has been used to develop a process model for a conceptual process to convert municipal solid waste (MSW) to hydrogen. The process consists of hydrothermal treatment of the MSW in water to create a slurry suitable as feedstock for an oxygen blown Texaco gasifier. A method of reducing the complicated MSW feed material to a manageable set of components is outlined along with a framework for modeling the stoichiometric changes associated with the hydrothermal treatment process. Model results indicate that 0.672 kmol/s of hydrogen can be produced from the processing of 30 kg/s (2600 tonne/day) of raw MSW. A number of variations on the basic processing parameters are explored and indicate that there is a clear incentive to reduce the inert fraction in the processed slurry feed and that cofeeding a low value heavy oil may be economically attractive.

  7. Regulatory Concerns on the In-Containment Water Storage System of the Korean Next Generation Reactor

    SciTech Connect (OSTI)

    Ahn, Hyung-Joon; Lee, Jae-Hun; Bang, Young-Seok; Kim, Hho-Jung [Korea Institute of Nuclear Safety (Korea, Republic of)

    2002-07-15T23:59:59.000Z

    The in-containment water storage system (IWSS) is a newly adopted system in the design of the Korean Next Generation Reactor (KNGR). It consists of the in-containment refueling water storage tank, holdup volume tank, and cavity flooding system (CFS). The IWSS has the function of steam condensation and heat sink for the steam release from the pressurizer and provides cooling water to the safety injection system and containment spray system in an accident condition and to the CFS in a severe accident condition. With the progress of the KNGR design, the Korea Institute of Nuclear Safety has been developing Safety and Regulatory Requirements and Guidances for safety review of the KNGR. In this paper, regarding the IWSS of the KNGR, the major contents of the General Safety Criteria, Specific Safety Requirements, Safety Regulatory Guides, and Safety Review Procedures were introduced, and the safety review items that have to be reviewed in-depth from the regulatory viewpoint were also identified.

  8. Solar heating and hot water system installed at St. Louis, Missouri. Final report

    SciTech Connect (OSTI)

    Not Available

    1980-04-01T23:59:59.000Z

    Information is provided on the solar heating and hot water system installed at the William Tao and Associates, Inc., office building in St. Louis, Missouri. The information consists of description, photos, maintenance and construction problems, final drawing, system requirements and manufacturer's component data. The solar system was designed to provide 50% of the hot water requirements and 45% of the space heating needs for a 900 square foot office space and drafting room. The solar facility has 252 square foot of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.

  9. Study of the impacts of regulations affecting the acceptance of Integrated Community Energy Systems: public utility, energy facility siting and municipal franchising regulatory programs in Arkansas. Preliminary background report

    SciTech Connect (OSTI)

    Feurer, D.A.; Weaver, C.L.; Gallagher, K.C.; Hejna, D.; Rielley, K.J.

    1980-01-01T23:59:59.000Z

    The Arkansas state constitution contains no provision dealing with public utility regulation. Title 73 of the Arkansas Statutes specifically provides for the regulation of public utilities. The Arkansas Public Service Commission is established by statute as a subagency of the Department of Commerce and is responsible for regulating electric, steam heating, and certain other kinds of utilities. The Commission consists of three members, each appointed by the governor with the approval of the Senate for a term of six years. The Commission has authority over all matters pertaining to the regulation and operation of gas companies, electric companies, and hydro-electric companies among other utilities enumerated in the statute. The role of local governments in the regulation of public utilities has been reduced by recent legislation. Municipal councils formerly had the power to regulate rate-making for investor owned utilities operating within their boundaries. However, as a result of 1977 amendments to the Public Utilities Act, ratemaking for privately owned electric, gas, telephone, and sewer utilities is now within the exclusive jurisdiction of the Public Service Commission. Public utility regulatory statutes, energy facility siting programs, and municipal franchising authority are examined to identify how they may impact on the ability of an organization, whether or not it be a regulated utility, to construct and operate an ICES.

  10. Financial sustainability in municipal solid waste management – Costs and revenues in Bahir Dar, Ethiopia

    SciTech Connect (OSTI)

    Lohri, Christian Riuji, E-mail: christian.lohri@eawag.ch; Camenzind, Ephraim Joseph, E-mail: ephraimcamenzind@hotmail.com; Zurbrügg, Christian, E-mail: christian.zurbruegg@eawag.ch

    2014-02-15T23:59:59.000Z

    Highlights: • Cost-revenue analysis over 2 years revealed insufficient cost-recovery. • Expenses for motorized secondary collection increased by 82% over two years. • Low fee collection rate and reliance on only one revenue stream are problematic. • Different options for cost reduction and enhanced revenue streams are recommended. • Good public–private alliance is crucial to plan and implement improvement measures. - Abstract: Providing good solid waste management (SWM) services while also ensuring financial sustainability of the system continues to be a major challenge in cities of developing countries. Bahir Dar in northwestern Ethiopia outsourced municipal waste services to a private waste company in 2008. While this institutional change has led to substantial improvement in the cleanliness of the city, its financial sustainability remains unclear. Is the private company able to generate sufficient revenues from their activities to offset the costs and generate some profit? This paper presents a cost-revenue analysis, based on data from July 2009 to June 2011. The analysis reveals that overall costs in Bahir Dar’s SWM system increased significantly during this period, mainly due to rising costs related to waste transportation. On the other hand, there is only one major revenue stream in place: the waste collection fee from households, commercial enterprises and institutions. As the efficiency of fee collection from households is only around 50%, the total amount of revenues are not sufficient to cover the running costs. This results in a substantial yearly deficit. The results of the research therefore show that a more detailed cost structure and cost-revenue analysis of this waste management service is important with appropriate measures, either by the privates sector itself or with the support of the local authorities, in order to enhance cost efficiency and balance the cost-revenues towards cost recovery. Delays in mitigating the evident financial deficit could else endanger the public-private partnership (PPP) and lead to failure of this setup in the medium to long term, thus also endangering the now existing improved and currently reliable service. We present four options on how financial sustainability of the SWM system in Bahir Dar might be enhanced: (i) improved fee collection efficiency by linking the fees of solid waste collection to water supply; (ii) increasing the value chain by sales of organic waste recycling products; (iii) diversifying revenue streams and financing mechanisms (polluter-pays-, cross-subsidy- and business-principles); and (iv) cost reduction and improved cost-effectiveness. We argue that in a PPP setup such as in Bahir Dar, a strong alliance between the municipality and private enterprise is important so that appropriate solutions for improved financial sustainability of a SWM system can be sought and implemented.

  11. The Pipe vs. The Shed: Waste Water compared with Natural Hydrology in an Urban Setting

    E-Print Network [OSTI]

    Lather, Alaska; Wozniak, Monika

    2011-01-01T23:59:59.000Z

    etc. ). Most oil and grease (aka sludge) are removed andoils, and greases; Page 14 of 20  winery waste; municipal water and wastewater sludge;

  12. How Much Water is Enough? Using PET to Develop Water Budgets for Residential landscapes

    E-Print Network [OSTI]

    White, R.; Havalak, R.; Nations, J.; Thomas, J.; Chalmers, D.; Dewey, D.

    2004-01-01T23:59:59.000Z

    &M University College Station, TX 77843-2474 ABSTRACT Conserving and reducing the amount of water used for landscape irrigation continues to be a major issue for municipalities throughout Texas and the nation. Landscape irrigation increases... dramatically during summer months and contributes substantially to peak demand placed on municipal water supplies. A survey of monthly water use during 2000 through 2002 for 800 residences of similar size and appraised value in College Station, Texas...

  13. Hot Water Heating System Operation and Energy Conservation 

    E-Print Network [OSTI]

    Shao, Z.; Chen, H.; Wei, P.

    2006-01-01T23:59:59.000Z

    heating period, and temperature-flow adjustment with frequency control. The study shows the most energy efficient operating method is a variable flow heating system, which should be popularized to the heating field....

  14. Improving the Water Efficiency of Cooling Production System

    E-Print Network [OSTI]

    Maheshwari, G.; Al-Hadban, Y.; Al-Taqi, H. H.; Alasseri, R.

    2010-01-01T23:59:59.000Z

    For most of the time, cooling towers (CTs) of cooling systems operate under partial load conditions and by regulating the air circulation with a variable frequency drive (VFD), significant reduction in the fan power can be achieved. In Kuwait...

  15. New Water Booster Pump System Reduces Energy Consumption by 80...

    Broader source: Energy.gov (indexed) [DOE]

    a highly efficient pumping system for their Pontiac Operations Complex in Pontiac, Michigan. In short, GM was able to replace five original 60- to 100-hp pumps with three 15-hp...

  16. Use of Produced Water in Recirculating Cooling Systems at Power Generating Facilities

    SciTech Connect (OSTI)

    Kent Zammit; Michael N. DiFilippo

    2005-07-01T23:59:59.000Z

    The purpose of this study is to evaluate produced water as a supplemental source of water for the San Juan Generating Station (SJGS). This study incorporates elements that identify produced water volume and quality, infrastructure to deliver it to SJGS, treatment requirements to use it at the plant, delivery and treatment economics, etc. SJGS, which is operated by Public Service of New Mexico (PNM) is located about 15 miles northwest of Farmington, New Mexico. It has four units with a total generating capacity of about 1,800 MW. The plant uses 22,400 acre-feet of water per year from the San Juan River with most of its demand resulting from cooling tower make-up. The plant is a zero liquid discharge facility and, as such, is well practiced in efficient water use and reuse. For the past few years, New Mexico has been suffering from a severe drought. Climate researchers are predicting the return of very dry weather over the next 30 to 40 years. Concern over the drought has spurred interest in evaluating the use of otherwise unusable saline waters. This deliverable describes possible test configurations for produced water demonstration projects at SJGS. The ability to host demonstration projects would enable the testing and advancement of promising produced water treatment technologies. Testing is described for two scenarios: Scenario 1--PNM builds a produced water treatment system at SJGS and incorporates planned and future demonstration projects into the design of the system. Scenario 2--PNM forestalls or decides not to install a produced water treatment system and would either conduct limited testing at SJGS (produced water would have to be delivered by tanker trucked) or at a salt water disposal facility (SWD). Each scenario would accommodate demonstration projects differently and these differences are discussed in this deliverable. PNM will host a demonstration test of water-conserving cooling technology--Wet Surface Air Cooling (WSAC) using cooling tower blowdown from the existing SJGS Unit 3 tower--during the summer months of 2005. If successful, there may be follow-on testing using produced water. WSAC is discussed in this deliverable. Recall that Deliverable 4, Emerging Technology Testing, describes the pilot testing conducted at a salt water disposal facility (SWD) by the CeraMem Corporation. This filtration technology could be a candidate for future demonstration testing and is also discussed in this deliverable.

  17. Introduction Increasing demands on limited water resources have made

    E-Print Network [OSTI]

    Sanderson, Mike

    (reclamation or reuse) an attractive option for extending water supplies. Treatment technologies have evolved has increasingly been used for municipal irrigation, toilet flushing, industrial cooling, and other varyconsiderablybetweensystems.Theuseofrecycledwater is particularly beneficial to extending water supplies in arid climates

  18. Hanford Site ground-water model: Geographic information system linkages and model enhancements, FY 1993

    SciTech Connect (OSTI)

    Wurstner, S.K.; Devary, J.L.

    1993-12-01T23:59:59.000Z

    Models of the unconfined aquifer are important tools that are used to (1) identify and quantify existing, emerging, or potential ground-water quality problems, (2) predict changes in ground-water flow and contaminant transport as waste-water discharge operations change, and (3) assess the potential for contaminants to migrate from the US Department of Energy`s Hanford Site through the ground water. Formerly, most of the numerical models developed at the Hanford Site were two-dimensional. However, contaminant concentrations cannot be accurately predicted with a two-dimensional model, which assumes a constant vertical distribution of contaminants in the aquifer. Development of two- and three-dimensional models of ground-water flow based on the Coupled Fluid, Energy, and Solute Transport (CFEST) code began in the mid- 1980s. The CFEST code was selected because of its ability to simulate both ground-water flow and contaminant transport. Physical processes that can be modeled by CFEST include aquifer geometry, heterogeneity, boundary conditions, and initial conditions. The CFEST ground-water modeling library has been integrated with the commercially available geographic information system (GIS) ARC/INFO. The display and analysis capabilities of a GIS are well suited to the size and diversity of databases being generated at the Hanford Site. The ability to visually inspect large databases through a graphical analysis tool provides a stable foundation for site assessments and ground-water modeling studies. Any ground-water flow model being used by an ongoing project should be continually updated and refined to reflect the most current knowledge of the system. The two-dimensional ground-water flow model being used in support of the Ground-Water Surveillance Project has recently been updated and enhanced. One major enhancement was the extension of the model area to include North Richland.

  19. Toward a Low-CarMunicipal Financing for Energy Efficiency and Solar Power

    E-Print Network [OSTI]

    Kammen, Daniel M.

    Toward a Low-CarMunicipal Financing for Energy Efficiency and Solar Power By Merrian C. Fuller, such as improving energy efficiency and add- ing solar photovoltaics (PV) and solar thermal systems to buildings, and the aver- age cost of natural gas has risen more than 10 percent a year for residential customers

  20. Sudhakar Yedla* and Sarika Kansal Economic insight into municipal solid waste

    E-Print Network [OSTI]

    Columbia University

    Sudhakar Yedla* and Sarika Kansal Economic insight into municipal solid waste management in Mumbai: a critical analysis 511 " Economic insight into solid waste management Conventional MSW management fails metropolitan city in India, presents the most critical solid waste management system in India. The present

  1. Municipal Solid Waste as an Energy Source by Roller-Grate Incineration

    E-Print Network [OSTI]

    Karnoski, P. J.

    1979-01-01T23:59:59.000Z

    The Grumman/VKW (Duesseldorf) Roller-Grate System was developed specifically to mass-burn municipal solid wastes achieving efficient combustion by a rolling and mixing action of the fuel bed, and independent control of primary air and roller speed...

  2. Project Profile: The Sacramento Municipal Utility District Consumnes Power Plant Solar Augmentation Project

    Broader source: Energy.gov [DOE]

    The Sacramento Municipal Utility District (SMUD), under the Concentrating Solar Power (CSP) Heat Integration for Baseload Renewable Energy Development (HIBRED) program, is demonstrating a hybrid CSP solar energy system that takes advantage of an existing electrical generator for its power block and transmission interconnection.

  3. Economic Analysis of a Brackish Water Photovoltaic-Operated (BWRO-PV) Desalination System: Preprint

    SciTech Connect (OSTI)

    Al-Karaghouli, A.; Kazmerski, L. L.

    2010-10-01T23:59:59.000Z

    The photovoltaic (PV)-powered reverse-osmosis (RO) desalination system is considered one of the most promising technologies in producing fresh water from both brackish and sea water, especially for small systems located in remote areas. We analyze the economic viability of a small PV-operated RO system with a capacity of 5 m3/day used to desalinate brackish water of 4000 ppm total dissolve solids, which is proposed to be installed in a remote area of the Babylon governorate in the middle of Iraq; this area possesses excellent insolation throughout the year. Our analysis predicts very good economic and environmental benefits of using this system. The lowest cost of fresh water achieved from using this system is US $3.98/ m3, which is very reasonable compared with the water cost reported by small-sized desalination plants installed in rural areas in other parts of the world. Our analysis shows that using this small system will prevent the release annually of 8,170 kg of CO2, 20.2 kg of CO, 2.23 kg of CH, 1.52 kg of particulate matter, 16.41 kg of SO2, and 180 kg of NOx.

  4. Impact flux of asteroids and water transport to the habitable zone in binary star systems

    E-Print Network [OSTI]

    Bancelin, D; Eggl, S; Dvorak, R

    2015-01-01T23:59:59.000Z

    By now, observations of exoplanets have found more than 50 binary star systems hosting 71 planets. We expect these numbers to increase as more than 70% of the main sequence stars in the solar neighborhood are members of binary or multiple systems. The planetary motion in such systems depends strongly on both the parameters of the stellar system (stellar separation and eccentricity) and the architecture of the planetary system (number of planets and their orbital behaviour). In case a terrestrial planet moves in the so-called habitable zone (HZ) of its host star, the habitability of this planet depends on many parameters. A crucial factor is certainly the amount of water. We investigate in this work the transport of water from beyond the snow-line to the HZ in a binary star system and compare it to a single star system.

  5. Arnold Schwarzenegger WATER HEATERS AND HOT WATER

    E-Print Network [OSTI]

    Arnold Schwarzenegger Governor WATER HEATERS AND HOT WATER DISTRIBUTION SYSTEMS: Lutz J.D. (Lawrence Berkeley National Laboratory). 2008. Water Heaters and Hot Water Distribution

  6. Modeling threat assessments of water supply systems using markov latent effects methodology.

    SciTech Connect (OSTI)

    Silva, Consuelo Juanita

    2006-12-01T23:59:59.000Z

    Recent amendments to the Safe Drinking Water Act emphasize efforts toward safeguarding our nation's water supplies against attack and contamination. Specifically, the Public Health Security and Bioterrorism Preparedness and Response Act of 2002 established requirements for each community water system serving more than 3300 people to conduct an assessment of the vulnerability of its system to a terrorist attack or other intentional acts. Integral to evaluating system vulnerability is the threat assessment, which is the process by which the credibility of a threat is quantified. Unfortunately, full probabilistic assessment is generally not feasible, as there is insufficient experience and/or data to quantify the associated probabilities. For this reason, an alternative approach is proposed based on Markov Latent Effects (MLE) modeling, which provides a framework for quantifying imprecise subjective metrics through possibilistic or fuzzy mathematics. Here, an MLE model for water systems is developed and demonstrated to determine threat assessments for different scenarios identified by the assailant, asset, and means. Scenario assailants include terrorists, insiders, and vandals. Assets include a water treatment plant, water storage tank, node, pipeline, well, and a pump station. Means used in attacks include contamination (onsite chemicals, biological and chemical), explosives and vandalism. Results demonstrated highest threats are vandalism events and least likely events are those performed by a terrorist.

  7. Comparison Between TRNSYS Software Simulation and F-Chart Program on Solar Domestic Hot Water System

    E-Print Network [OSTI]

    Haberl, J. S.; Baltazar, J. C.; Mao, C.

    2012-01-01T23:59:59.000Z

    This study presents the accuracy test of a TRNSYS Solar Domestic Hot Water (SDHW) System simulation. The testing is based on comparing the results with the F-Chart software. The selected system to carry out the tests was the Active Solar Domestic...

  8. Comparison Between TRNSYS Software Simulation and F-Chart Program on Solar Domestic Hot Water System 

    E-Print Network [OSTI]

    Haberl, J. S.; Baltazar, J. C.; Mao, C.

    2012-01-01T23:59:59.000Z

    This study presents the accuracy test of a TRNSYS Solar Domestic Hot Water (SDHW) System simulation. The testing is based on comparing the results with the F-Chart software. The selected system to carry out the tests was the Active Solar Domestic...

  9. Solar heating and hot water system installed at Charlotte Memorial Hospital, Charlotte, North Carolina. Final report

    SciTech Connect (OSTI)

    None

    1981-05-01T23:59:59.000Z

    Included in this report is detailed information regarding the design and installation of a heating and hot water system in a commercial application. This information includes descriptions of system and building, design philosophy, control logic operation modes, design and installation drawing and a brief description of problems encountered and their solutions.

  10. Statistical comparison of leachate from hazardous, codisposal, and municipal solid waste landfills

    SciTech Connect (OSTI)

    Gibbons, R.D.; Dolan, D.G.; May, H.; O'Leary, K.; O'Hara, R.

    1999-09-30T23:59:59.000Z

    There has been considerable debate regarding the chemical characterization of landfill leachate in general and the comparison of various types of landfill leachate (e.g., hazardous, codisposal, and municipal) in particular. For example, the preamble to the US EPA Subtitle D regulation (40 CFR Parts 257 and 258) suggests that there are no significant differences between the number and concentration of toxic constituents in hazardous versus municipal solid waste landfill leachate. The purpose of this paper is to statistically test this hypothesis in a large leachate database comprising 1490 leachate samples from 283 sample points (i.e., monitoring location such as a leachate sump) in 93 landfill waste cells (i.e., a section of a facility that took a specific waste stream or collection of similar waste streams) from 48 sites with municipal, codisposal, or hazardous waste site histories. Results of the analysis reveal clear differention between landfill leachate types, both in terms of constituents detected and their concentrations. The result of the analysis is a classification function that can estimate the probability that new leachate or ground water sample was produced by the disposal of municipal, codisposal, or hazardous waste. This type of computation is illustrated, and applications of the model to Superfund cost-allocation problems are discussed.

  11. CC Retrofits and Optimal Controls for Hot Water Systems 

    E-Print Network [OSTI]

    Wu, L.; Liu, M.; Wang, G.

    2007-01-01T23:59:59.000Z

    and exterior zones. Each AHU has design airflow of 45,000 CFM. The high gas usage is caused by a dual-duct system with CAV boxes, which is an outdated and inefficient technology. Pneumatic controls make the operation and maintenance more difficult and do...

  12. Energy Savings with High Temperature Water Generation Systems 

    E-Print Network [OSTI]

    Manicke, A. C.

    1982-01-01T23:59:59.000Z

    ~lation and cost savings can be real i zed by all us~rs and markets. With the application of cogeneration, HTW can be added to provide very high system I effic iencies firing all types of fuel s. Saving energy has and will continue to be uppermost in our mind...

  13. A Systems Framework for Assessing Plumbing Products-Related Water Conservation

    SciTech Connect (OSTI)

    Williams, Alison; Dunham Whitehead, Camilla; Lutz, James

    2011-12-02T23:59:59.000Z

    Reducing the water use of plumbing products—toilets, urinals, faucets, and showerheads —has been a popular conservation measure. Improved technologies have created opportunities for additional conservation in this area. However, plumbing products do not operate in a vacuum. This paper reviews the literature related to plumbing products to determine a systems framework for evaluating future conservation measures using these products. The main framework comprises the following categories: water use efficiency, product components, product performance, source water, energy, and plumbing/sewer infrastructure. This framework for analysis provides a starting point for professionals considering future water conservation measures to evaluate the need for additional research, collaboration with other standards or codes committees, and attachment of additional metrics to water use efficiency (such as performance).

  14. Lakeland Electric- Solar Water Heating Program

    Broader source: Energy.gov [DOE]

    Lakeland Electric, a municipal utility in Florida, is the nation's first utility to offer solar-heated domestic hot water on a "pay-for-energy" basis. The utility has contracted with a solar...

  15. Evaluating Water Transfers in Irrigation Districts

    E-Print Network [OSTI]

    Ghimire, Narishwar

    2013-04-11T23:59:59.000Z

    The participation of irrigation districts (IDs) in surface water transfers from agriculture-to-municipal uses is studied by examining IDs’ economic and political behavior, comparing their performance with non-districts (non-IDs), and analyzing...

  16. Planning for municipal solid waste recycling

    SciTech Connect (OSTI)

    Belnay, G.A.

    1991-01-01T23:59:59.000Z

    This research identifies those community characteristics and program components that have resulted in early, consistent, high levels of recycling participation in New Jersey. Discriminant analysis of socio-economic, demographic, institutional, and motivational factors is used to classify each of the state's 567 minor civil divisions into groups that describe participation levels. Of the four hypotheses advanced to explain the variation of recycling around the state, leadership emerges as the key factor in local program success. Local political and governmental leaders set the municipal recycling agenda, and through their knowledge, programs that fit the unique characteristics of their town are designed and aggressively implemented. Significant savings in the municipality's solid waste disposal budget and the added bonus of State Tonnage Grant Award Revenues are obtained by the urban, well-established, experienced recyclers identified by the analysis and confirmed by the individual case studies discussed.

  17. Data summary of municipal solid waste management alternatives

    SciTech Connect (OSTI)

    Not Available

    1992-10-01T23:59:59.000Z

    This appendix provides information on fluidized-bed combustion (FBC) technology as it has been applied to municipal waste combustion (MWC). A review of the literature was conducted to determine: (1) to what extent FBC technology has been applied to MWC, in terms of number and size of units was well as technology configuration; (2) the operating history of facilities employing FBC technology; and (3) the cost of these facilities as compared to conventional MSW installations. Where available in the literature, data on operating and performance characteristics are presented. Tabular comparisons of facility operating/cost data and emissions data have been complied and are presented. The literature review shows that FBC technology shows considerable promise in terms of providing improvements over conventional technology in areas such as NOx and acid gas control, and ash leachability. In addition, the most likely configuration to be applied to the first large scale FBC dedicated to municipal solid waste (MSW) will employ circulating bed (CFB) technology. Projected capital costs for the Robbins, Illinois 1600 ton per day CFB-based waste-to-energy facility are competitive with conventional systems, in the range of $125,000 per ton per day of MSW receiving capacity.

  18. Pressure suppression containment system for boiling water reactor

    DOE Patents [OSTI]

    Gluntz, D.M.; Nesbitt, L.B.

    1997-01-21T23:59:59.000Z

    A system is disclosed for suppressing the pressure inside the containment of a BWR following a postulated accident. A piping subsystem is provided which features a main process pipe that communicates the wetwell airspace to a connection point downstream of the guard charcoal bed in an offgas system and upstream of the main bank of delay charcoal beds which give extensive holdup to offgases. The main process pipe is fitted with both inboard and outboard containment isolation valves. Also incorporated in the main process pipe is a low-differential-pressure rupture disk which prevents any gas outflow in this piping whatsoever until or unless rupture occurs by virtue of pressure inside this main process pipe on the wetwell airspace side of the disk exceeding the design opening (rupture) pressure differential. The charcoal holds up the radioactive species in the noncondensable gas from the wetwell plenum by adsorption, allowing time for radioactive decay before the gas is vented to the environs. 3 figs.

  19. Pressure suppression containment system for boiling water reactor

    DOE Patents [OSTI]

    Gluntz, Douglas M. (San Jose, CA); Nesbitt, Loyd B. (San Jose, CA)

    1997-01-01T23:59:59.000Z

    A system for suppressing the pressure inside the containment of a BWR following a postulated accident. A piping subsystem is provided which features a main process pipe that communicates the wetwell airspace to a connection point downstream of the guard charcoal bed in an offgas system and upstream of the main bank of delay charcoal beds which give extensive holdup to offgases. The main process pipe is fitted with both inboard and outboard containment isolation valves. Also incorporated in the main process pipe is a low-differential-pressure rupture disk which prevents any gas outflow in this piping whatsoever until or unless rupture occurs by virtue of pressure inside this main process pipe on the wetwell airspace side of the disk exceeding the design opening (rupture) pressure differential. The charcoal holds up the radioactive species in the noncondensable gas from the wetwell plenum by adsorption, allowing time for radioactive decay before the gas is vented to the environs.

  20. Modeling water uptake by a root system growing in a fixed soil volume

    E-Print Network [OSTI]

    Albrieu, J L Blengino; Tarzia, D A

    2015-01-01T23:59:59.000Z

    The water uptake by roots of plants is examined for an ideal situation, with an approximation that resembles plants growing in pots, meaning that the total soil volume is fixed. We propose a coupled water uptake-root growth model. A one-dimensional model for water flux and water uptake by a root system growing uniformly distributed in the soil is presented, and the Van Genuchten model for the transport of water in soil is used. The governing equations are represented by a moving boundary model for which the root length, as a function of time, is prescribed. The solution of the model is obtained by front-fixing and finite element methods. Model predictions for water uptake by a same plant growing in loam, silt and clay soils are obtained and compared. A sensitivity analysis to determine relative effects on water uptake when system parameters are changed is also presented and shows that the model and numerical method proposed are more sensitive to the root growth rate than to the rest of the parameters. This se...

  1. Water Rights Analysis Package (WRAP) River System Hydrology

    E-Print Network [OSTI]

    Wurbs, R.

    2013-02-20T23:59:59.000Z

    monthly evaporation less precipitation depths. The primary HYD output is SIM input FLO and EVA files of IN and EV records or these SIM hydrology input data as a data storage system DSS file. HYD also includes options for reading and writing stream flow... reservoir surface net evaporation less precipitation depths which are input to SIM as a file with filename extension EVA or DSS Chapter 1 Introduction 3 The monthly stream flow volumes and net evaporation-precipitation depths cover a specified...

  2. Dynamic Optimization for Optimal Control of Water Distribution Systems

    E-Print Network [OSTI]

    Ertin, Emre

    , Mathew L. Moore and Kevin L. Priddy Battelle Memorial Institute Cognitive Systems Group 505 King Avenue.E.) E.E.: E-mail: ertine@battelle.org, A.N.D.: E-mail: deana@battelle.org M.L.M.: E-mail: mathewml@battelle.org, K.L.P.: E-mail:priddy@battelle.org #12;Figure 1. Boosting station schematics 1977. A uniform

  3. Life Cycle Water Consumption and Water Resource Assessment for Utility-Scale Geothermal Systems: An In-Depth Analysis of Historical and Forthcoming EGS Projects

    SciTech Connect (OSTI)

    Schroeder, Jenna N.

    2013-08-31T23:59:59.000Z

    This report is the third in a series of reports sponsored by the U.S. Department of Energy Geothermal Technologies Program in which a range of water-related issues surrounding geothermal power production are evaluated. The first report made an initial attempt at quantifying the life cycle fresh water requirements of geothermal power-generating systems and explored operational and environmental concerns related to the geochemical composition of geothermal fluids. The initial analysis of life cycle fresh water consumption of geothermal power-generating systems identified that operational water requirements consumed the vast majority of water across the life cycle. However, it relied upon limited operational water consumption data and did not account for belowground operational losses for enhanced geothermal systems (EGSs). A second report presented an initial assessment of fresh water demand for future growth in utility-scale geothermal power generation. The current analysis builds upon this work to improve life cycle fresh water consumption estimates and incorporates regional water availability into the resource assessment to improve the identification of areas where future growth in geothermal electricity generation may encounter water challenges.

  4. Life Cycle Water Consumption and Water Resource Assessment for Utility-Scale Geothermal Systems: An In-Depth Analysis of Historical and Forthcoming EGS Projects

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Schroeder, Jenna N.

    This report is the third in a series of reports sponsored by the U.S. Department of Energy Geothermal Technologies Program in which a range of water-related issues surrounding geothermal power production are evaluated. The first report made an initial attempt at quantifying the life cycle fresh water requirements of geothermal power-generating systems and explored operational and environmental concerns related to the geochemical composition of geothermal fluids. The initial analysis of life cycle fresh water consumption of geothermal power-generating systems identified that operational water requirements consumed the vast majority of water across the life cycle. However, it relied upon limited operational water consumption data and did not account for belowground operational losses for enhanced geothermal systems (EGSs). A second report presented an initial assessment of fresh water demand for future growth in utility-scale geothermal power generation. The current analysis builds upon this work to improve life cycle fresh water consumption estimates and incorporates regional water availability into the resource assessment to improve the identification of areas where future growth in geothermal electricity generation may encounter water challenges.

  5. Life Cycle Water Consumption and Water Resource Assessment for Utility-Scale Geothermal Systems: An In-Depth Analysis of Historical and Forthcoming EGS Projects

    SciTech Connect (OSTI)

    Clark, Corrie E. [Environmental Science Division] [Environmental Science Division; Harto, Christopher B. [Environmental Science Division] [Environmental Science Division; Schroeder, Jenna N. [Environmental Science Division] [Environmental Science Division; Martino, Louis E. [Environmental Science Division] [Environmental Science Division; Horner, Robert M. [Environmental Science Division] [Environmental Science Division

    2013-11-05T23:59:59.000Z

    This report is the third in a series of reports sponsored by the U.S. Department of Energy Geothermal Technologies Program in which a range of water-related issues surrounding geothermal power production are evaluated. The first report made an initial attempt at quantifying the life cycle fresh water requirements of geothermal power-generating systems and explored operational and environmental concerns related to the geochemical composition of geothermal fluids. The initial analysis of life cycle fresh water consumption of geothermal power-generating systems identified that operational water requirements consumed the vast majority of water across the life cycle. However, it relied upon limited operational water consumption data and did not account for belowground operational losses for enhanced geothermal systems (EGSs). A second report presented an initial assessment of fresh water demand for future growth in utility-scale geothermal power generation. The current analysis builds upon this work to improve life cycle fresh water consumption estimates and incorporates regional water availability into the resource assessment to improve the identification of areas where future growth in geothermal electricity generation may encounter water challenges. This report is divided into nine chapters. Chapter 1 gives the background of the project and its purpose, which is to assess the water consumption of geothermal technologies and identify areas where water availability may present a challenge to utility-scale geothermal development. Water consumption refers to the water that is withdrawn from a resource such as a river, lake, or nongeothermal aquifer that is not returned to that resource. The geothermal electricity generation technologies evaluated in this study include conventional hydrothermal flash and binary systems, as well as EGSs that rely on engineering a productive reservoir where heat exists, but where water availability or permeability may be limited. Chapter 2 describes the approach and methods for this work and identifies the four power plant scenarios evaluated: a 20-MW EGS binary plant, a 50-MW EGS binary plant, a 10-MW hydrothermal binary plant, and a 50-MW hydrothermal flash plant. The methods focus on (1) the collection of data to improve estimation of EGS stimulation volumes, aboveground operational consumption for all geothermal technologies, and belowground operational consumption for EGS; and (2) the mapping of the geothermal and water resources of the western United States to assist in the identification of potential water challenges to geothermal growth. Chapters 3 and 4 present the water requirements for the power plant life cycle. Chapter 3 presents the results of the current data collection effort, and Chapter 4 presents the normalized volume of fresh water consumed at each life cycle stage per lifetime energy output for the power plant scenarios evaluated. Over the life cycle of a geothermal power plant, from construction through 30 years of operation, the majority of water is consumed by plant operations. For the EGS binary scenarios, where dry cooling was assumed, belowground operational water loss is the greatest contributor depending upon the physical and operational conditions of the reservoir. Total life cycle water consumption requirements for air-cooled EGS binary scenarios vary between 0.22 and 1.85 gal/kWh, depending upon the extent of belowground operational water consumption. The air-cooled hydrothermal binary and flash plants experience far less fresh water consumption over the life cycle, at 0.04 gal/kWh. Fresh water requirements associated with air- cooled binary operations are primarily from aboveground water needs, including dust control, maintenance, and domestic use. Although wet-cooled hydrothermal flash systems require water for cooling, these plants generally rely upon the geofluid, fluid from the geothermal reservoir, which typically has high salinity and total dissolved solids concentration and is much warmer than normal groundwater sources, for their cooling water needs; thus,

  6. Global Evaluation of the ISBA-TRIP Continental Hydrological System. Part I: Comparison to GRACE Terrestrial Water Storage Estimates

    E-Print Network [OSTI]

    Ribes, Aurélien

    In earth system models, the partitioning of precipitation among the variations of continental water storage climate system sim- ulated by earth system models (ESMs). The continental freshwater reservoirs represent

  7. Water-saving liquid-gas conditioning system

    DOE Patents [OSTI]

    Martin, Christopher; Zhuang, Ye

    2014-01-14T23:59:59.000Z

    A method for treating a process gas with a liquid comprises contacting a process gas with a hygroscopic working fluid in order to remove a constituent from the process gas. A system for treating a process gas with a liquid comprises a hygroscopic working fluid comprising a component adapted to absorb or react with a constituent of a process gas, and a liquid-gas contactor for contacting the working fluid and the process gas, wherein the constituent is removed from the process gas within the liquid-gas contactor.

  8. Optimal planning for the sustainable utilization of municipal solid waste

    SciTech Connect (OSTI)

    Santibañez-Aguilar, José Ezequiel [Chemical Engineering Department, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán 58060 (Mexico); Ponce-Ortega, José María, E-mail: jmponce@umich.mx [Chemical Engineering Department, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán 58060 (Mexico); Betzabe González-Campos, J. [Institute of Chemical and Biological Researches, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán 58060 (Mexico); Serna-González, Medardo [Chemical Engineering Department, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán 58060 (Mexico); El-Halwagi, Mahmoud M. [Chemical Engineering Department, Texas A and M University, College Station, TX 77843 (United States); Adjunct Faculty at the Chemical and Materials Engineering Department, Faculty of Engineering, King Abdulaziz University, P.O. Box 80204, Jeddah 21589 (Saudi Arabia)

    2013-12-15T23:59:59.000Z

    Highlights: • An optimization approach for the sustainable management of municipal solid waste is proposed. • The proposed model optimizes the entire supply chain network of a distributed system. • A case study for the sustainable waste management in the central-west part of Mexico is presented. • Results shows different interesting solutions for the case study presented. - Abstract: The increasing generation of municipal solid waste (MSW) is a major problem particularly for large urban areas with insufficient landfill capacities and inefficient waste management systems. Several options associated to the supply chain for implementing a MSW management system are available, however to determine the optimal solution several technical, economic, environmental and social aspects must be considered. Therefore, this paper proposes a mathematical programming model for the optimal planning of the supply chain associated to the MSW management system to maximize the economic benefit while accounting for technical and environmental issues. The optimization model simultaneously selects the processing technologies and their location, the distribution of wastes from cities as well as the distribution of products to markets. The problem was formulated as a multi-objective mixed-integer linear programing problem to maximize the profit of the supply chain and the amount of recycled wastes, where the results are showed through Pareto curves that tradeoff economic and environmental aspects. The proposed approach is applied to a case study for the west-central part of Mexico to consider the integration of MSW from several cities to yield useful products. The results show that an integrated utilization of MSW can provide economic, environmental and social benefits.

  9. Reducing booster-pump-induced contaminant intrusion in Indian water systems with a self-actuated, back-pressure regulating valve

    E-Print Network [OSTI]

    Taylor, David Donald James

    2014-01-01T23:59:59.000Z

    Intermittently-operated water systems struggle to equitably and effectively distribute clean water to customers. One common customer response to intermittency is to supplement the water system's pressure by using a household, ...

  10. Valley Center Municipal Water District | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTown of Ladoga,planning methodologies andVacant Jump to:ValeValleBrook, Oklahoma:

  11. Solar hot water system installed at Quality Inn, Key West, Florida. Final report

    SciTech Connect (OSTI)

    Not Available

    1980-04-01T23:59:59.000Z

    The solar energy hot water system installed in the Quality Inn, Key West, Florida, which consists of four buildings, is described. Three buildings are low-rise, two-story buildings containing 100 rooms. The fourth is a four-story building with 48 rooms. The solar system was designed to provide approximately 50% of the energy required for the domestic hot water system. The solar system consists of approximately 1400 ft/sup 2/ of flat plate collector, two 500 gal storage tanks, a circulating pump, and a controller. Operation of the system was begun in April 1978, and has continued to date with only three minor interruptions for pump repair. In the first year of operation, it was determined that the use of the solar facility resulted in 40% fuel savings.

  12. Field Test and Evaluation Report Five Photovoltaic Power Systems for the City of Tucson

    Broader source: Energy.gov [DOE]

    Members of the DOE solar energy Tiger Team tested five municipally owned, grid connected photovoltaic (PV) power systems for the City of Tucson on March 26 and 27, 2008. The five PV systems tested were Southeast Service Center, Clements Fitness Center, and Thonydale water treatment plant systems 1, 2, and 3. During all tests, skies were virtually cloudless with only occasional, high cirrus present, and none during array testing.

  13. A version of this paper will be presented at the Fifth Dubrovnik Conference on Sustainable Development of Energy, Water, and Environment Systems in Dubrovnik, Croatia, September

    E-Print Network [OSTI]

    Hughes, Larry

    Development of Energy, Water, and Environment Systems in Dubrovnik, Croatia, September 2009. ERG/200905 Energy

  14. Pilot scale test of a produced water-treatment system for initial removal of organic compounds

    SciTech Connect (OSTI)

    Sullivan, Enid J [Los Alamos National Laboratory; Kwon, Soondong [UT-AUSTIN; Katz, Lynn [UT-AUSTIN; Kinney, Kerry [UT-AUSTIN

    2008-01-01T23:59:59.000Z

    A pilot-scale test to remove polar and non-polar organics from produced water was performed at a disposal facility in Farmington NM. We used surfactant-modified zeolite (SMZ) adsorbent beds and a membrane bioreactor (MBR) in combination to reduce the organic carbon content of produced water prior to reverse osmosis (RO). Reduction of total influent organic carbon (TOC) to 5 mg/L or less is desirable for efficient RO system operation. Most water disposed at the facility is from coal-bed gas production, with oil production waters intermixed. Up to 20 gal/d of produced water was cycled through two SMZ adsorbent units to remove volatile organic compounds (BTEX, acetone) and semivolatile organic compounds (e.g., napthalene). Output water from the SMZ units was sent to the MBR for removal of the organic acid component of TOC. Removal of inorganic (Mn and Fe oxide) particulates by the SMZ system was observed. The SMZ columns removed up to 40% of the influent TOC (600 mg/L). BTEX concentrations were reduced from the initial input of 70 mg/L to 5 mg/L by the SMZ and to an average of 2 mg/L after the MBR. Removal rates of acetate (input 120-170 mg/L) and TOC (input up to 45 mg/L) were up to 100% and 92%, respectively. The water pH rose from 8.5 to 8.8 following organic acid removal in the MBR; this relatively high pH was likely responsible for observed scaling of the MBR internal membrane. Additional laboratory studies showed the scaling can be reduced by metered addition of acid to reduce the pH. Significantly, organic removal in the MBR was accomplished with a very low biomass concentration of 1 g/L throughout the field trial. An earlier engineering evaluation shows produced water treatment by the SMZ/MBR/RO system would cost from $0.13 to $0.20 per bbl at up to 40 gpm. Current estimated disposal costs for produced water are $1.75 to $4.91 per bbl when transportation costs are included, with even higher rates in some regions. Our results suggest that treatment by an SMZ/MBR/RO system may be a feasible alternative to current methods for produced water treatment and disposal.

  15. Potential for Hepa filter damage from water spray systems in filter plenums

    SciTech Connect (OSTI)

    Bergman, W.; Fretthold, J.K.; Slawsld, J.W.

    1997-01-01T23:59:59.000Z

    The water spray systems in high efficiency particulate air (HEPA) filter plenums that are used in nearly all Department of Energy (DOE) facilities for protection against fire was designed under the assumption that the HEPA filters would not be damaged by the water sprays. The most likely scenario for filter damage involves filter plugging by the water spray, followed by the fan blowing out the filter medium. A number of controlled laboratory tests that were previously conducted in the late 1980s are reviewed in this paper to provide a technical basis for the potential HEPA filter damage by the water spray system in HEPA filter plenums. In addition to the laboratory tests, the scenario for HEPA filter damage during fires has also occurred in the field. Afire in a four-stage, HEPA filter plenum at Rocky Flats in 1980 caused the first three stages of HEPA filters to blow out of their housing and the fourth stage to severely bow. Details of this recently declassified fire are presented in this paper. Although these previous findings suggest serious potential problems exist with the current water spray system in filter plenum , additional studies are required to confirm unequivocally that DOE`s critical facilities are at risk.

  16. How Much Water is Enough? Using PET to Develop Water Budgets for Residential landscapes 

    E-Print Network [OSTI]

    White, R.; Havalak, R.; Nations, J.; Thomas, J.; Chalmers, D.; Dewey, D.

    2004-01-01T23:59:59.000Z

    Conserving and reducing the amount of water used for landscape irrigation continues to be a major issue for municipalities throughout Texas and the nation. Landscape irrigation increases dramatically during summer months and contributes...

  17. Marshall Municipal Utilities- Commercial Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Marshall Municipal Utilities offers incentives to commercial customers which help cover the installation costs of energy efficient lighting, heating and cooling equipment, motors, variable...

  18. River Falls Municipal Utilities- Business Energy Efficiency Rebate Program (Wisconsin)

    Broader source: Energy.gov [DOE]

    River Falls Municipal Utility (RFMU) offers a variety of rebates to business customers for implementing energy efficient equipment upgrades. Rebates are available for commercial lighting, central...

  19. Standards for Municipal Small Wind Regulations and Model Ordinance

    Broader source: Energy.gov [DOE]

    In July 2008, New Hampshire enacted legislation designed to prevent municipalities from adopting ordinances or regulations that place unreasonable limits on or hinder the performance of wind energy...

  20. Hercules Municipal Utility- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Hercules Municipal Utility provides financial incentives for its residential members to increase the energy efficiency of participating homes. Rebates are offered for a variety of home appliances...