Sample records for meters kilometers temperature

  1. Two-Meter Temperature Surveys for Geothermal Exploration Project...

    Open Energy Info (EERE)

    being considered in this project. Initial results from two-meter temperature surveys on Navy managed land near Fallon, Nevada indicate the presence of several temperature...

  2. Shallow (2-meter) temperature surveys in Colorado

    SciTech Connect (OSTI)

    Zehner, Richard E.

    2012-02-01T23:59:59.000Z

    Citation Information: Originator: Geothermal Development Associates, Reno, Nevada Publication Date: 2012 Title: Colorado 2m Survey Edition: First Publication Information: Publication Place: Reno Nevada Publisher: Geothermal Development Associates, Reno, Nevada Description: Shallow temperature surveys are useful in early-stage geothermal exploration to delineate surface outflow zones, with the intent to identify the source of upwelling, usually a fault. Detailed descriptions of the 2-meter survey method and equipment design can be found in Coolbaugh et al. (2007) and Sladek et al. (2007), and are summarized here. The survey method was devised to measure temperature as far below the zone of solar influence as possible, have minimal equilibration time, and yet be portable enough to fit on the back of an all-terrain vehicle (ATV); Figure 2). This method utilizes a direct push technology (DPT) technique where 2.3 m long, 0.54” outer diameter hollow steel rods are pounded into the ground using a demolition hammer. Resistance temperature devices (RTD) are then inserted into the rods at 2-meter depths, and allowed to equilibrate for one hour. The temperatures are then measured and recorded, the rods pulled out of the ground, and re-used at future sites. Usually multiple rods are planted over the course of an hour, and then the sampler returns back to the first station, measures the temperatures, pulls the rods, and so on, to eliminate waiting time. At Wagon Wheel Gap, 32 rods were planted around the hot springs between June 20 and July 1, 2012. The purpose was to determine the direction of a possible upflow fault or other structure. Temperatures at 1.5m and 2m depths were measured and recorded in the attribute table of this point shapefile. Several anomalous temperatures suggest that outflow is coming from a ~N60W striking fault or shear zone that contains the quartz-fluorite-barite veins of the adjacent patented mining claims. It should be noted that temperatures at 2m depth vary according to the amount of solar heating from above, as well as possible geothermal heating from below. Spatial Domain: Extent: Top: 4490310.560635 m Left: 150307.008238 m Right: 433163.213617 m Bottom: 4009565.915398 m Contact Information: Contact Organization: Geothermal Development Associates, Reno, Nevada Contact Person: Richard “Rick” Zehner Address: 3740 Barron Way City: Reno State: NV Postal Code: 89511 Country: USA Contact Telephone: 775-737-7806 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGS’1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System 1984 (WGS ’1984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

  3. Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment...

    Open Energy Info (EERE)

    Temperature Gradient Drilling Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Use of Rapid Temperature Measurements at a 2-Meter Depth to...

  4. Development Of 2-Meter Soil Temperature Probes And Results Of...

    Open Energy Info (EERE)

    Temperature Probes And Results Of Temperature Survey Conducted At Desert Peak, Nevada, Usa Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper:...

  5. Improvements in Shallow (Two-Meter) Temperature Measurements...

    Open Energy Info (EERE)

    to study influences on shallow temperature measurements related to geological and solar radiation factors specifically, slope orientation, ground composition and albedo. In...

  6. Net Metering

    Broader source: Energy.gov [DOE]

    In April 2008, Kentucky enacted legislation that expanded its net metering law by requiring utilities to offer net metering to customers that generate electricity with photovoltaic (PV), wind,...

  7. Local wall heat flux/temperature meter for convective flow and method of utilizing same

    DOE Patents [OSTI]

    Boyd, Ronald D.; Ekhlassi, Ali; Cofie, Penrose

    2004-11-30T23:59:59.000Z

    According to one embodiment of the invention, a method includes providing a conduit having a fluid flowing therethrough, disposing a plurality of temperature measurement devices inside a wall of the conduit, positioning at least some of the temperature measurement devices proximate an inside surface of the wall of the conduit, positioning at least some of the temperature measurement devices at different radial positions at the same circumferential location within the wall, measuring a plurality of temperatures of the wall with respective ones of the temperature measurement devices to obtain a three-dimensional temperature topology of the wall, determining the temperature dependent thermal conductivity of the conduit, and determining a multi-dimensional thermal characteristic of the inside surface of the wall of the conduit based on extrapolation of the three-dimensional temperature topology and the temperature dependent thermal conductivities.

  8. Net Metering

    Broader source: Energy.gov [DOE]

    In Massachusetts, the state's investor-owned utilities must offer net metering. Municipal utilities are not obligated to offer net metering, but they may do so voluntarily. (There are no electric...

  9. Net Metering

    Broader source: Energy.gov [DOE]

    The Indiana Utility Regulatory Commission (IURC) adopted rules for net metering in September 2004, requiring the state's investor-owned utilities (IOUs) to offer net metering to all electric...

  10. Net Metering

    Broader source: Energy.gov [DOE]

    New Jersey's net-metering rules apply to all residential, commercial and industrial customers of the state's investor-owned utilities and energy suppliers (and certain competitive municipal...

  11. Net Metering

    Broader source: Energy.gov [DOE]

    Wyoming enacted legislation in February 2001 that established statewide net metering. The law applies to investor-owned utilities, electric cooperatives and irrigation districts. Eligible...

  12. Net Metering

    Broader source: Energy.gov [DOE]

    Net metering has been available in Oklahoma since 1988 under Oklahoma Corporation Commission (OCC) Order 326195. The OCC's rules require investor-owned utilities and electric cooperatives under...

  13. Net Metering

    Broader source: Energy.gov [DOE]

    Missouri enacted legislation in June 2007 (S.B. 54)* requiring all electric utilities -- investor-owned utilities, municipal utilities and electric cooperatives -- to offer net metering to...

  14. Metering Approaches

    Broader source: Energy.gov [DOE]

    Metering approaches vary depending on facility design and intended purpose (e.g., administrative offices, laboratory, warehouse, etc.). No one approach fits all applications. In fact, different...

  15. Net Metering

    Broader source: Energy.gov [DOE]

    Illinois enacted legislation in August 2007 (S.B. 680) requiring investor-owned utilities in Illinois to begin offering net metering by April 1, 2008. In May 2008, the Illinois Commerce Commissio...

  16. Net Metering

    Broader source: Energy.gov [DOE]

    NOTE: In December 15, 2014 the New York Public Service Commission (PSC) issued an order directing the investor owned utilities in the State to file net metering tariff revisions doubling the agg...

  17. Net Metering

    Broader source: Energy.gov [DOE]

    Nevada's original net-metering law for renewable-energy systems was enacted in 1997 and amended in 2001, 2003, 2005, 2007, 2011, 2013, and 2015. Systems up to one megawatt (MW) in capacity that...

  18. Net Metering

    Broader source: Energy.gov [DOE]

    Note: The program web site listed above links to the Maryland Public Service Commission's Net Metering Working Group page, which contains a variety of information resources related to the ongoing...

  19. Net Metering

    Broader source: Energy.gov [DOE]

    [http://nebraskalegislature.gov/FloorDocs/101/PDF/Final/LB436.pdf LB 436], signed in May 2009, established statewide net metering rules for all electric utilities in Nebraska. The rules apply to...

  20. Net Metering

    Broader source: Energy.gov [DOE]

    The North Carolina Utilities Commission (NCUC) requires the state’s three investor-owned utilities -- Duke Energy, Progress Energy and Dominion North Carolina Power -- to make net metering...

  1. Net Metering

    Broader source: Energy.gov [DOE]

    Net metering is available to all "qualifying facilities" (QFs), as defined by the federal Public Utility Regulatory Policies Act of 1978 (PURPA)*, which pertains to systems up to 80 megawatts (MW)...

  2. Net Metering

    Broader source: Energy.gov [DOE]

    Montana's net-metering law, enacted in July 1999, applies to all customers of investor-owned utilities. Systems up to 50 kilowatts (kW) in capacity that generate electricity using solar, wind or...

  3. Net Metering

    Broader source: Energy.gov [DOE]

    The Public Service Commission of Wisconsin (PSC) issued an order on January 26, 1982 requiring all regulated utilities to file tariffs allowing net metering to customers that generate electricity...

  4. Net Metering

    Broader source: Energy.gov [DOE]

    Rhode Island allows net metering for systems up to five megawatts (MW) in capacity that are designed to generate up to 100% of the electricity that a home or other facility uses. Systems that...

  5. Net Metering

    Broader source: Energy.gov [DOE]

    '''''Note: In March 2011, Virginia enacted HB 1983, which increased the residential net-metering limit to 20 kW. However, residential facilities with a capacity of greater than 10 kW must pay a...

  6. Net Metering

    Broader source: Energy.gov [DOE]

    Net metering in West Virginia is available to all retail electricity customers. System capacity limits vary depending on the customer type and electric utility type, according to the following...

  7. Net Metering

    Broader source: Energy.gov [DOE]

    North Dakota's net-metering policy, adopted in 1991 by the state Public Service Commission (PSC), applies to renewable-energy systems and combined heat and power (CHP) systems up to 100 kilowatts ...

  8. Net Metering

    Broader source: Energy.gov [DOE]

    Oregon has established separate net-metering programs for the state's primary investor-owned utilities (PGE and PacifiCorp), and for its municipal utilities and electric cooperatives.

  9. Net Metering

    Broader source: Energy.gov [DOE]

    '''''The MPSC is reviewing state interconnection and net metering policies in [http://efile.mpsc.state.mi.us/efile/viewcase.php?casenum=15919&submit.x=... Case U-15919].'''''...

  10. Net Metering

    Broader source: Energy.gov [DOE]

    '''''NOTE: Legislation enacted in 2011 and 2012 (S.B. 1652, H.B. 3036, and S.B. 3811) has changed several aspects of net metering in Illinois. For customers in competitive classes as of July 1,...

  11. Net Metering

    Broader source: Energy.gov [DOE]

    Utah law requires their only investor-owned utility, Rocky Mountain Power (RMP), and most electric cooperatives* to offer net metering to customers who generate electricity using solar energy, wind...

  12. Net Metering

    Broader source: Energy.gov [DOE]

    Washington's net-metering law applies to systems up to 100 kilowatts (kW) in capacity that generate electricity using solar, wind, hydro, biogas from animal waste, or combined heat and power...

  13. Net Metering

    Broader source: Energy.gov [DOE]

    '''''Note: H.F. 729, enacted in May 2013, includes many changes to Minnesota's net metering law. These changes are described above, but most will not take effect until rules are implemented at the...

  14. Saturation meter

    DOE Patents [OSTI]

    Gregurech, S.

    1984-08-01T23:59:59.000Z

    A saturation meter for use in a pressurized water reactor plant comprising a differential pressure transducer having a first and second pressure sensing means and an alarm. The alarm is connected to the transducer and is preset to activate at a level of saturation prior to the formation of a steam void in the reactor vessel.

  15. Technologie Smart metering Technologie Smart metering

    E-Print Network [OSTI]

    Technologie Smart metering Technologie Smart metering 29Bulletin 9/2014 Innovative Dienste mit intelligenten Stromzählern Standby- und Kühlgeräteverbrauch aus Smart-Meter-Daten Smart Meter ermöglichen weit, kommunikationsfähigen Stromzählern, fort. Smart Meter ermöglichen eine effizi- entere Rechnungsstellung, da sie Mess

  16. Palau- Net Metering

    Broader source: Energy.gov [DOE]

    The Palau Net Metering Act of 2009 established net metering on the Island of Palau. Net metering was implemented in order to:

  17. Kansas- Net Metering

    Broader source: Energy.gov [DOE]

    Kansas adopted the Net Metering and Easy Connection Act in May 2009 (see K.S.A. 66-1263 through 66-1271), establishing net metering for customers of investor-owned utilities in Kansas. Net metering...

  18. LADWP- Net Metering (California)

    Broader source: Energy.gov [DOE]

    LADWP allows its customers to net meter their photovoltaic (PV), wind, and hybrid systems with a capacity of not more than one megawatt. LADWP will provide the necessary metering equipment unless...

  19. LADWP- Net Metering

    Broader source: Energy.gov [DOE]

    LADWP allows its customers to net meter their photovoltaic (PV), wind, and hybrid systems with a capacity of not more than one megawatt. LADWP will provide the necessary metering equipment unless...

  20. Progress Energy- Net Metering

    Broader source: Energy.gov [DOE]

    In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulated electric utilities; the order incorporates a net metering...

  1. Net Metering Rules (Arkansas)

    Broader source: Energy.gov [DOE]

    The Net Metering Rules are promulgated under the authority of the Arkansas Public Service Commission. These rules are created to establish rules for net energy metering and interconnection. These...

  2. Duke Energy- Net Metering

    Broader source: Energy.gov [DOE]

    In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulating utilities; the order incorporates a net metering settlement...

  3. Utility Metering- AGL Resources

    Broader source: Energy.gov [DOE]

    Presentation—given at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meeting—discusses AGL Resources metering, including interruptible rate customers, large users, and meeting federal metering goals.

  4. 105Lunar Crater Frequency Distributions This image of the 800-meter x 480-meter region near the Apollo-11 landing pad

    E-Print Network [OSTI]

    the Apollo-11 landing pad (arrow) was taken by the Lunar Reconnaissance Orbiter (LRO). It reveals hundreds of craters covering the landing area with sizes as small as 5 meters. The Apollo-11 landing pad is near and gives the surface density of craters near the Apollo-11 landing site in terms of craters per kilometer 2

  5. Net Energy Metering (NEM)

    Broader source: Energy.gov (indexed) [DOE]

    the Arizona Public Service Co. (APS) request for a charge on future rooftop solar panel installations connected to the grid under the state's net energy metering (NEM)...

  6. High Energy Neutrino Astronomy: Towards Kilometer-Scale Detectors

    E-Print Network [OSTI]

    F. Halzen

    2001-03-13T23:59:59.000Z

    Of all high-energy particles, only neutrinos can directly convey astronomical information from the edge of the universe---and from deep inside the most cataclysmic high-energy processes. Copiously produced in high-energy collisions, travelling at the velocity of light, and not deflected by magnetic fields, neutrinos meet the basic requirements for astronomy. Their unique advantage arises from a fundamental property: they are affected only by the weakest of nature's forces (but for gravity) and are therefore essentially unabsorbed as they travel cosmological distances between their origin and us. Many of the outstanding mysteries of astrophysics may be hidden from our sight at all wavelengths of the electromagnetic spectrum because of absorption by matter and radiation between us and the source. For example, the hot dense regions that form the central engines of stars and galaxies are opaque to photons. In other cases, such as supernova remnants, gamma ray bursters, and active galaxies, all of which may involve compact objects or black holes at their cores, the precise origin of the high-energy photons emerging from their surface regions is uncertain. Therefore, data obtained through a variety of observational windows---and especially through direct observations with neutrinos---may be of cardinal importance. In this talk, the scientific goals of high energy neutrino astronomy and the technical aspects of water and ice Cherenkov detectors are examined, and future experimental possibilities, including a kilometer-square deep ice neutrino telescope, are explored.

  7. DC attenuation meter

    DOE Patents [OSTI]

    Hargrove, Douglas L.

    2004-09-14T23:59:59.000Z

    A portable, hand-held meter used to measure direct current (DC) attenuation in low impedance electrical signal cables and signal attenuators. A DC voltage is applied to the signal input of the cable and feedback to the control circuit through the signal cable and attenuators. The control circuit adjusts the applied voltage to the cable until the feedback voltage equals the reference voltage. The "units" of applied voltage required at the cable input is the system attenuation value of the cable and attenuators, which makes this meter unique. The meter may be used to calibrate data signal cables, attenuators, and cable-attenuator assemblies.

  8. PSEG Long Island- Net Metering

    Broader source: Energy.gov [DOE]

    Although PSEG Long Island’s net metering policy is not governed by the State’s net metering law, the provisions are similar to the State law. Net metering is available for residential, non-reside...

  9. Guam- Net Metering

    Broader source: Energy.gov [DOE]

    Guam's Public Utilities Commission (PUC) reviewed net metering and interconnection during a regular meeting in February 2009 (Docket 08-10). Please contact the [http://www.guampuc.com/ Guam PUC]...

  10. Net Metering (Ontario, Canada)

    Broader source: Energy.gov [DOE]

    Ontario's net metering regulation allows you to send electricity generated from renewable sources to the electrical grid for a credit toward your energy costs. Here's how it works. Your utility...

  11. Puerto Rico- Net Metering

    Broader source: Energy.gov [DOE]

    Puerto Rico enacted net-metering legislation in August 2007, allowing customers of Puerto Rico Electric Power Authority (PREPA) to use electricity generated by solar, wind or "other" renewable...

  12. Economics of Energy Metering

    E-Print Network [OSTI]

    Duncan, J. D.

    1979-01-01T23:59:59.000Z

    become necessary to accurately measure energy usage (primarily fuel and steam) throughout the plant. There are currently several projects in the million dollar range to upgrade and add new metering to these flows. This paper will discuss the justification...

  13. Avista Utilities- Net Metering

    Broader source: Energy.gov [DOE]

    Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has developed a net...

  14. Ashland Electric- Net Metering

    Broader source: Energy.gov [DOE]

    In 1996, Ashland adopted a net-metering program that includes simple interconnection guidelines. The program encourages the adoption of renewable-energy systems by committing the city to purchase,...

  15. Idaho Power- Net Metering

    Broader source: Energy.gov [DOE]

    Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has developed a net...

  16. Washington City Power- Net Metering

    Broader source: Energy.gov [DOE]

    Washington City adopted a net-metering program, including interconnection procedures, in January 2008.* Net metering is available to residential and commercial customers that generate electricity...

  17. Regression analysis of WMATA metering information

    SciTech Connect (OSTI)

    Not Available

    1983-12-01T23:59:59.000Z

    The PEPCO provided a magnetic tape that contained energy usage (pulses) data as given in the PEPCO account. The data had 15-min pulses for 26 traction energy meters which were in operation during 1980. The time span was January 20, 1980, to January 19, 1981. Out of 26 traction metering data provided by PEPCO, 18 meters were in DC, 5 meters were in MD, and 3 meters were in VA jurisdictions. The data were converted into Fortran readable form, using program RU0A09.FOR. The system flow chart is shown. Using A, plots were created of summary statistics, which provided through bar charts information on mean, standard deviation, and maximum of power demand. Using B, regression analyses of power vs. car-miles/hour and degree-days for revenue operating and nonoperating periods were established. Using C, energy consumption histograms on each time period for various meters were created. The regression analysis which was done on PEPCO metering data in order to determine the dependence of traction energy usages on car-miles and daily temperature is described in detail.

  18. Liquid metal Flow Meter - Final Report

    SciTech Connect (OSTI)

    Andersen, C.; Hoogendoom, S.; Hudson, B.; Prince, J.; Teichert, K.; Wood, J.; Chase, K.

    2007-01-30T23:59:59.000Z

    Measuring the flow of liquid metal presents serious challenges. Current commercially-available flow meters use ultrasonic, electromagnetic, and other technologies to measure flow, but are inadequate for liquid metal flow measurement because of the high temperatures required by most liquid metals. As a result of the reactivity and high temperatures of most liquid metals, corrosion and leakage become very serious safety concerns. The purpose of this project is to develop a flow meter for Lockheed Martin that measures the flow rate of molten metal in a conduit.

  19. Neutron dose equivalent meter

    DOE Patents [OSTI]

    Olsher, Richard H. (Los Alamos, NM); Hsu, Hsiao-Hua (Los Alamos, NM); Casson, William H. (Los Alamos, NM); Vasilik, Dennis G. (Los Alamos, NM); Kleck, Jeffrey H. (Menlo Park, CA); Beverding, Anthony (Foster City, CA)

    1996-01-01T23:59:59.000Z

    A neutron dose equivalent detector for measuring neutron dose capable of accurately responding to neutron energies according to published fluence to dose curves. The neutron dose equivalent meter has an inner sphere of polyethylene, with a middle shell overlying the inner sphere, the middle shell comprising RTV.RTM. silicone (organosiloxane) loaded with boron. An outer shell overlies the middle shell and comprises polyethylene loaded with tungsten. The neutron dose equivalent meter defines a channel through the outer shell, the middle shell, and the inner sphere for accepting a neutron counter tube. The outer shell is loaded with tungsten to provide neutron generation, increasing the neutron dose equivalent meter's response sensitivity above 8 MeV.

  20. Energy Metering Audit Procedure

    E-Print Network [OSTI]

    Whitaker, W. S.

    Energy Meterilg Audtt Procedure Wiliam S Whitaker Engineering Specialist T X E INC. laPorte Texas INTROOUCI'ION This paper describes the recent audit of the utility distriooticn meters in a petrochanica1 plant. These meters measure the steam... audit Will also identify losses in the distriooticn eMrtem itself. '!he results of the audit can be used to recx:umand charYJes in operatin] procedures ~th respect to energy soorces. In aci:iiticn, ,the audit oou1d \\.Il'1COVer prob1ans...

  1. Elbow mass flow meter

    DOE Patents [OSTI]

    McFarland, Andrew R. (College Station, TX); Rodgers, John C. (Santa Fe, NM); Ortiz, Carlos A. (Bryan, TX); Nelson, David C. (Santa Fe, NM)

    1994-01-01T23:59:59.000Z

    Elbow mass flow meter. The present invention includes a combination of an elbow pressure drop generator and a shunt-type mass flow sensor for providing an output which gives the mass flow rate of a gas that is nearly independent of the density of the gas. For air, the output is also approximately independent of humidity.

  2. N. Mariana Islands- Net Metering

    Broader source: Energy.gov [DOE]

    Note: The Commonwealth Utility Corporation issued a moratorium on net metering. However, Public Law 18-62 signed September 6, 2014 states that net metering should be available to all residential...

  3. Rocky Mountain Power- Net Metering

    Broader source: Energy.gov [DOE]

    Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has a net-metering...

  4. SCE&G- Net Metering

    Broader source: Energy.gov [DOE]

    In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulated electric utilities; the order incorporates a net metering...

  5. EPAct 2005 Metering Guidance Overview

    Office of Environmental Management (EM)

    * Agency policiesguidance Potential Roles for Utilities * Guidanceupdates on time-based pricing * Metering services * Finance installations * Other? Useful Documents * Guidance...

  6. Portable wastewater flow meter

    DOE Patents [OSTI]

    Hunter, Robert M. (320 S. Wilson Ave., Bozeman, MT 59715)

    1990-01-01T23:59:59.000Z

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under full pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  7. Portable wastewater flow meter

    DOE Patents [OSTI]

    Hunter, Robert M. (320 S. Wilson Ave., Bozeman, MT 59715)

    1999-02-02T23:59:59.000Z

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under fill pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  8. O&M Metering Guidance

    Broader source: Energy.gov [DOE]

    Presentation covers the O&M Metering Guidance and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Rapid City, South Dakota.

  9. Net Metering (New Brunswick, Canada)

    Broader source: Energy.gov [DOE]

    The NB Power Net Metering program provides customers with the option to connect their own environmentally sustainable generation unit to NB Power's distribution system. The program allows customers...

  10. Electric Metering | Department of Energy

    Energy Savers [EERE]

    The Forrestal electric meters provide daily read-outs and comparison of data on electricity consumption for overhead lighting and power outlets. The purpose is to measure...

  11. Status of aeromagnetic survey coverage of Yucca Mountain and vicinity to a radius of about 140 kilometers, southwestern Nevada and southeastern California, 1992

    SciTech Connect (OSTI)

    Sikora, R.F.; Ponce, D.A.; Oliver, H.W.

    1993-12-31T23:59:59.000Z

    Fifty aeromagnetic surveys in the southwestern part of Nevada and the southeastern part of California have been evaluated to assess the quality and coverage of aeromagnetic data within 140 kilometers (km) of a potential nuclear waste repository at Yucca Mountain, Nevada. The compilation shows that all the study area is covered by aeromagnetic surveys, but in some areas, particularly in the Death Valley region, new surveys flown with closer flight line spacing and lower elevations than the existing coverage are needed. In addition, the California part of the study area needs to be analytically continued downward to 305 meters (m) above ground level to provide a consistent data set for interpretation of subsurface geologic structures.

  12. AN ELECTRICAL OXYGEN-TEMPERATURE METER

    E-Print Network [OSTI]

    in the West; manages giant hydroelectric power systems; administers grazing and forestry programs on federally

  13. Impact of orifice metering uncertainties

    SciTech Connect (OSTI)

    Stuart, J.W. (Pacific Gas and Electric Co., San Francisco, CA (USA))

    1990-12-01T23:59:59.000Z

    In a recent utility study, attributed 38% of its unaccounted-for UAF gas to orifice metering uncertainty biasing caused by straightening vanes. How this was determined and how this applied to the company's orifice meters is described. Almost all (97%) of the company's UAF gas was found to be attributed to identifiable accounting procedures, measurement problems, theft and leakage.

  14. Modeling temporal variations of electrical resistivity associated with pore pressure change in a kilometer-scale

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    (hautot@univ-brest.fr) [1] From 1995 to 1998 the natural electric field was monitored with an array of 20 role of fluids in the distortion of the induced electric fields. Electromagnetic methods could provide in a kilometer-scale natural system Sophie Hautot School of Geosciences, University of Edinburgh, Edinburgh, UK

  15. Valley Electric Association- Net Metering

    Broader source: Energy.gov [DOE]

    The Board of Directors for Valley Electric Association (VEA) approved net metering in April 2008. The rules apply to systems up to 30 kW, though owners of larger systems may be able to negotiate...

  16. Electric Metering | Department of Energy

    Energy Savers [EERE]

    has installed meters in the James Forrestal Building that will enable DOE to measure electricity use and costs in its headquarters facility. You may explore this data further by...

  17. Austin Energy- Net Metering (Texas)

    Broader source: Energy.gov [DOE]

    Austin Energy, the municipal utility of Austin Texas, offers net metering for renewable energy systems up to 20 kilowatts (kW) to its non-residential retail electricity customers. The definition of...

  18. Healthcare Energy Metering Guidance (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2011-07-01T23:59:59.000Z

    This brochure is intended to help facility and energy managers plan and prioritize investments in energy metering. It offers healthcare-specific examples of metering applications, benefits, and steps that other health systems can reproduce. It reflects collaborative input from the U.S. Department of Energy national laboratories and the health system members of the DOE Hospital Energy Alliance's Benchmarking and Measurement Project Team.

  19. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, L.H.

    1994-08-16T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

  20. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, Louis H. (Knoxville, TN)

    1995-01-01T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

  1. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, L.H.

    1995-10-17T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

  2. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, Louis H. (Knoxville, TN)

    1994-01-01T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

  3. Square Kilometer Array Telescope - Precision Reference Frequency Synchronisation via 1f-2f Dissemination

    E-Print Network [OSTI]

    Wang, B; Gao, C; Bai, Y; Dong, J W; Wang, L J

    2015-01-01T23:59:59.000Z

    The Square Kilometer Array (SKA) is an international effort to build the world's largest radio telescope, with one square kilometer collecting area. Besides its ambitious scientific objectives, such as probing the cosmic dawn and cradle of life, SKA also demands several revolutionary technological breakthroughs, with ultra-high precision synchronisation of the frequency references for thousands of antennas being one of them. In this report, aimed at applications to SKA, we demonstrate a frequency reference synchronization and dissemination scheme with the phase noise compensation function placed at the client site. Hence, one central hub can be linked to a large number of client sites, forming a star-shaped topology. As a performance test, the 100 MHz reference signal from a Hydrogen maser clock is disseminated and recovered at two remote sites. Phase noise characteristics of the recovered reference frequency signal coincides with that of the hydrogen-maser source and satisfies SKA requirement.

  4. NUCLEAR MIXING METERS FOR CLASSICAL NOVAE

    SciTech Connect (OSTI)

    Kelly, Keegan J.; Iliadis, Christian; Downen, Lori; Champagne, Art [Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3255 (United States); José, Jordi [Departament de Física i Enginyeria Nuclear, EUETIB, Universitat Politècnica de Catalunya, E-08036 Barcelona (Spain)

    2013-11-10T23:59:59.000Z

    Classical novae are caused by mass transfer episodes from a main-sequence star onto a white dwarf via Roche lobe overflow. This material possesses angular momentum and forms an accretion disk around the white dwarf. Ultimately, a fraction of this material spirals in and piles up on the white dwarf surface under electron-degenerate conditions. The subsequently occurring thermonuclear runaway reaches hundreds of megakelvin and explosively ejects matter into the interstellar medium. The exact peak temperature strongly depends on the underlying white dwarf mass, the accreted mass and metallicity, and the initial white dwarf luminosity. Observations of elemental abundance enrichments in these classical nova events imply that the ejected matter consists not only of processed solar material from the main-sequence partner but also of material from the outer layers of the underlying white dwarf. This indicates that white dwarf and accreted matter mix prior to the thermonuclear runaway. The processes by which this mixing occurs require further investigation to be understood. In this work, we analyze elemental abundances ejected from hydrodynamic nova models in search of elemental abundance ratios that are useful indicators of the total amount of mixing. We identify the abundance ratios ?CNO/H, Ne/H, Mg/H, Al/H, and Si/H as useful mixing meters in ONe novae. The impact of thermonuclear reaction rate uncertainties on the mixing meters is investigated using Monte Carlo post-processing network calculations with temperature-density evolutions of all mass zones computed by the hydrodynamic models. We find that the current uncertainties in the {sup 30}P(p, ?){sup 31}S rate influence the Si/H abundance ratio, but overall the mixing meters found here are robust against nuclear physics uncertainties. A comparison of our results with observations of ONe novae provides strong constraints for classical nova models.

  5. Precision metering of germinated seeds

    E-Print Network [OSTI]

    Elliot, Gregory Lawrence

    1990-01-01T23:59:59.000Z

    actuated by an electrical solenoid was used to mechanically capture individual seeds. Air was used to eject the seeds from the system. A new single file device employing dilution flow was tested at rates as high as ten seeds per second. It produced... distribution was found to adequately represent the data. The metering system was tested at ejection rates ranging from 1. 3 to 4. 5 seeds per second, with most tests at rates between two and three seeds per second. The performance of the metering system...

  6. Metered Rack PDU The American Power Conversion (APC) Metered

    E-Print Network [OSTI]

    van Hemmen, J. Leo

    StruXureManager interfaces. Outlets. The Rack PDU has twenty (20) IEC-320-C13 outlets and four (4) IEC-320-C19 outlets. The 10-foot (3.05-meter) power cord terminates with a IEC-309 32 A connector. AP7853 #12;*990-1898-001* 990-1898-001 08/2004 Specifications for AP7853 Electrical Input connector IEC-309 32 A plug Output

  7. Meters

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHighand Retrievals from aRodMIT-Harvard Center forMetallicH. Skinner,sc 620

  8. Meters

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |IsLove Your HomeOverview and HistoryMEMS: Inside theand RP-1

  9. Government Program Briefing: Smart Metering

    Office of Energy Efficiency and Renewable Energy (EERE)

    This document is adapted and updated from a memo delivered to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the U.S. Department of Energy (DOE) Project Officer in March 2008. This briefing piece provides an overview of the benefits, costs, and challenges of smart metering.

  10. Government Program Briefing: Smart Metering

    SciTech Connect (OSTI)

    Doris, E.; Peterson, K.

    2011-09-01T23:59:59.000Z

    This document is adapted and updated from a memo delivered to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the U.S. Department of Energy (DOE) Project Officer in March 2008. This briefing piece provides an overview of the benefits, costs, and challenges of smart metering.

  11. Heating Energy Meter Validation for Apartments

    E-Print Network [OSTI]

    Cai, B.; Li, D.; Hao, B.

    2006-01-01T23:59:59.000Z

    Household heat metering is the core of heating system reform. Because of many subjective and objective factors, household heat metering has not been put into practice to a large extent in China. In this article, the research subjects are second...

  12. Heating Energy Meter Validation for Apartments 

    E-Print Network [OSTI]

    Cai, B.; Li, D.; Hao, B.

    2006-01-01T23:59:59.000Z

    Household heat metering is the core of heating system reform. Because of many subjective and objective factors, household heat metering has not been put into practice to a large extent in China. In this article, the research subjects are second...

  13. Long Island Power Authority- Net Metering

    Broader source: Energy.gov [DOE]

    : Note: In October 2012 the LIPA Board of Trustees adopted changes to the utility's net metering tariff that permit remote net metering for non-residential solar and wind energy systems, and farm...

  14. City of St. George- Net Metering

    Broader source: Energy.gov [DOE]

    The St. George City Council adopted a [http://www.sgcity.org/wp/power/NetMeteringPolicy.pdf net-metering program for area utilities], including interconnection procedures, in October 2005.* The...

  15. Privacy-Preserving Smart Metering Alfredo Rial

    E-Print Network [OSTI]

    Bernstein, Phil

    Privacy-Preserving Smart Metering Alfredo Rial K.U.Leuven, ESAT/COSIC & IBBT Leuven, Belgium General Terms Security Keywords Billing, Smart metering, Cryptographic Protocol, Verifiable Computing 1 of smart meter data for more accurate forecasting, Permission to make digital or hard copies of all or part

  16. PQMII POWER QUALITY METER INSTRUCTION MANUAL 11 PQMII Power Quality Meter

    E-Print Network [OSTI]

    Meyers, Steven D.

    #12;#12;#12;PQMII POWER QUALITY METER ­ INSTRUCTION MANUAL 1­1 PQMII Power Quality Meter Chapter 1 Multilin PQMII Power Quality Meter is an ideal choice for continuous monitoring of a single or three-phase system. It provides metering for current, voltage, real power, reactive power, apparent power, energy use

  17. Electric Metering | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you sure you want toworldPowerHome | Documents MemorandumEEOElectric Metering

  18. Discussion series on PURPA related topics: metering

    SciTech Connect (OSTI)

    Sturgeon, J I

    1980-08-01T23:59:59.000Z

    Time-differentiated metering of electricity consumption and demand is required in both rate-structure experimentation and the implementation of most time-of-use rate designs. Time-differentiated metering takes three major forms: multi-register watthour meters, magnetic-tape recording meters, and remote automatic meter-reading systems. The majority of projects selected magnetic-tape meters for their flexibility with respect to rate structure, load-survey capabilities, and ready availability. The small-scale, experimental nature of the projects reduced the significance of the large difference in per-unit cost and operational/maintenance complexity between this form of metering and the multi-register form. Magnetic-tape meters are not likely candidates for system-wide implementation of time-differentiated metering. Automatic remote-meter-reading systems were not adequately available during the project years; those projects attempting to use these were unable to bring them to full operational status before project termination, due to the many problems of design, quality control, and equipment acquisition encountered. Delays in acquisition and problems of quality control also followed the selection of magnetic-tape meters and multi-register meters by a number of the projects. Though less complex than automatic remote-reading systems, these technologies are still new and more complex than standard watthour metering. Thus, both equipment vendors and utilities encountered numerous problems in getting properly functioning meters to the service entrances on time. A variety of factors contributed to installation delays, including unforeseen space limitations, incompatible wiring, problems of task organization, and customer reluctance.

  19. activity meters: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Dienste mit intelligenten Stromzhlern Standby- und Khlgerteverbrauch aus Smart-Meter-Daten Smart Meter ermglichen weit, kommunikationsfhigen...

  20. 0 20 40 60 80 100 Miles 0 20 40 60 80 100 120 140 160 Kilometers

    E-Print Network [OSTI]

    Pasternack, Gregory B.

    20 40 60 80 100 Miles 0 20 40 60 80 100 120 140 160 Kilometers UC Davis Water Management Research Group Aplication Efficiency: Dry Beans 2001 Developed as a cooperative project between University of California, Davis United States Geological Survey and California Department of Water Resources Map prepared

  1. Farmington Electric Utility System- Net Metering

    Broader source: Energy.gov [DOE]

    Net metering rules developed by the New Mexico Public Regulation Commission (PRC) apply to the state's investor-owned utilities and electric cooperatives. Municipal utilities, which are not...

  2. Ellsworth Air Force Base Advanced Metering Project

    Broader source: Energy.gov [DOE]

    Presentation covers the Ellsworth Air Force Base Advanced Metering project and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

  3. Assessment of Demand Response and Advanced Metering

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    #12;#12;2008 Assessment of Demand Response and Advanced Metering Staff Report Federal Energy metering penetration and potential peak load reduction from demand response have increased since 2006. Significant activity to promote demand response or to remove barriers to demand response occurred at the state

  4. Proton recoil scintillator neutron rem meter

    DOE Patents [OSTI]

    Olsher, Richard H. (Los Alamos, NM); Seagraves, David T. (Los Alamos, NM)

    2003-01-01T23:59:59.000Z

    A neutron rem meter utilizing proton recoil and thermal neutron scintillators to provide neutron detection and dose measurement. In using both fast scintillators and a thermal neutron scintillator the meter provides a wide range of sensitivity, uniform directional response, and uniform dose response. The scintillators output light to a photomultiplier tube that produces an electrical signal to an external neutron counter.

  5. The Coldest Cubic Meter in the Known Universe

    E-Print Network [OSTI]

    Ouellet, Jonathan

    2014-01-01T23:59:59.000Z

    CUORE is a 741 kg array of TeO2 bolometers that will search for the neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso in Italy, where it will begin taking data in 2015. The CUORE cryostat will cool several metric tonnes of material to below 1 K and the CUORE detector itself will operate at a typical temperature of 10 mK. At this temperature, the CUORE detector will be the coldest contiguous cubic meter in the known Universe.

  6. automated seepage meters: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Index 1 An Overview on Advance Metering System CiteSeer Summary: Abstract The term "Smart meter " typically refers to an electrical meter, but the term is also starting to be...

  7. Working With Your Utility to Obtain Metering Services

    Broader source: Energy.gov [DOE]

    Presentation—given at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meeting—covers the government metering requirement, the U.S. Department of Defense (DoD) metering directive, and customer metering services available from utilities.

  8. Portable Liquid Flow Metering for Energy Conservation Programs

    E-Print Network [OSTI]

    Miles, F. J.

    1982-01-01T23:59:59.000Z

    Flow metering is absolutely required for evaluation of energy usage. In fact, determining usages and heat balances without metering are simply educated guesses. Recent technological innovations in flow metering have produced clamp-on, portable flow...

  9. U.S. Virgin Islands- Net Metering

    Broader source: Energy.gov [DOE]

    In February 2007, the U.S. Virgin Islands Public Services Commission approved a limited net-metering program for residential and commercial photovoltaic (PV), wind-energy or other renewable energ...

  10. Murray City Power- Net Metering Pilot Program

    Broader source: Energy.gov [DOE]

    Under a pilot program, Murray City Power offers net metering to customers that generate electricity using photovoltaic (PV), wind-electric or hydroelectric systems with a maximum capacity of 10...

  11. BPA Metering Services Editing and Estimating Procedures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    be used to scale the estimated interval data with a shape projection applied. If SCADA data is available and has been mapped to the point of metering, it may be used for...

  12. Advanced metering techniques in the federal sector

    SciTech Connect (OSTI)

    Szydlowski, R.F.; Chvala, W.D. Jr.; Halverson, M.A.

    1994-12-01T23:59:59.000Z

    The lack of utility metering in the federal sector has hampered introduction of direct billing of individual activities at most military installations. Direct billing will produce accountability for the amount of energy used and is a positive step toward self-directed energy conservation. For many installations, automatic meter reading (AMR) is a cost-effective way to increase the number of meters while reducing labor requirements and providing energy conservation analysis capabilities. The communications technology used by some of the AMR systems provides other demand-side management (DSM) capabilities. This paper summarizes the characteristics and relative merits of several AMR/DSM technologies that may be appropriate for the federal sector. A case study of an AMR system being installed at Fort Irwin, California, describes a cost-effective two-way radio communication system used for meter reading and load control.

  13. Hydro-Québec Net Metering (Quebec, Canada)

    Broader source: Energy.gov [DOE]

    In line with Hydro-Québec's commitment to the environment and sustainable development, Hydro-Québec is supporting self-generation with a new rate offering: the net metering option. This option...

  14. City of New Orleans- Net Metering

    Broader source: Energy.gov [DOE]

    In May 2007, the New Orleans City Council adopted net-metering rules that are similar to rules adopted by the Louisiana Public Service Commission (PSC) in November 2005. The City Council's rules...

  15. Algorithms for revenue metering and their evaluation 

    E-Print Network [OSTI]

    Martinez-Lagunes, Rodrigo

    2000-01-01T23:59:59.000Z

    Power components are measured for revenue metering and other purposes such as power control and power factor compensation. The definitions of the power components (active, reactive and apparent power, as well as, power factor) under sinusoidal...

  16. Algorithms for revenue metering and their evaluation

    E-Print Network [OSTI]

    Martinez-Lagunes, Rodrigo

    2000-01-01T23:59:59.000Z

    ALGORITHMS FOR REVENUE METERING AND THEIR EVALUATION A Thesis by RODRIGO MARTINEZ-LAGUNES Submitted to the Office of Graduate Studies of Texas AdcM University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE May... 2000 Major Subject: Electrical Engineering ALGORITHMS FOR REVENUE METERING AND THEIR EVALUATION A Thesis By RODRIGO MARTINEZ-LAGUNES Submitted to Texas A&M University in partial fulfillment of the requirements for the degree of MASTER...

  17. Solutia: Utilizing Sub-Metering to Drive Energy Project Approvals...

    Broader source: Energy.gov (indexed) [DOE]

    plant. Solutia: Utilizing Sub-Metering to Drive Energy Project Approvals Through Data (July 2011) More Documents & Publications Nissan North America: How Sub-Metering...

  18. LM to Meet Energy Metering Goals Through Enhanced Data Collection...

    Office of Environmental Management (EM)

    to Meet Energy Metering Goals Through Enhanced Data Collection at Groundwater Treatment Systems LM to Meet Energy Metering Goals Through Enhanced Data Collection at Groundwater...

  19. Metering Best Practices: A Guide to Achieving Utility Resource...

    Office of Environmental Management (EM)

    Metering Best Practices: A Guide to Achieving Utility Resource Efficiency Metering Best Practices: A Guide to Achieving Utility Resource Efficiency Guide describes information...

  20. A Scalable Communication Architecture for Advanced Metering Infrastructure

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    , Communication Architecture, Inter-connecting Overlays. I. INTRODUCTION In AMI system, smart meters measure of data is collected from each smart meter every 15 minutes [Bernaudo et al 2010]. In addition, meter data, the connection from the MDMSs to smart meters following the client-server model as normally to be compatible

  1. Monitoring Massive Appliances by a Minimal Number of Smart Meters

    E-Print Network [OSTI]

    Wang, Yongcai

    56 Monitoring Massive Appliances by a Minimal Number of Smart Meters YONGCAI WANG, XIAOHONG HAO. This article presents a framework for deploying a minimal number of smart meters to accurately track the ON of required smart meters is studied by an entropy-based approach, which qualifies the impact of meter

  2. SOLVENT DISPERSION AND FLOW METER CALCULATION RESULTS

    SciTech Connect (OSTI)

    Nash, C.; Fondeur, F.; Peters, T.

    2013-06-21T23:59:59.000Z

    Savannah River National Laboratory (SRNL) found that the dispersion numbers for the six combinations of CSSX:Next Generation Solvent (NGS) “blend” and pure NGS versus salt solution, caustic wash, and strip aqueous solutions are all good. The dispersion numbers are indications of processability with centrifugal contactors. A comparison of solvent physical and thermal properties shows that the Intek™ solvent flow meter in the plant has a reading biased high versus calibrated flow when NGS is used, versus the standard CSSX solvent. The flow meter, calibrated for CSSX solvent, is predicted to read 2.8 gpm of NGS in a case where the true flow of NGS is 2.16 gpm.

  3. Improvements in Shallow (Two-Meter) Temperature Measurements and Data

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, search OpenEIHesperia,IDGWP WindSatellite InterferometricImperium

  4. High Temperature 300°C Directional Drilling System

    Broader source: Energy.gov [DOE]

    Project objective: provide a directional drilling system that can be used at environmental temperatures of up to 300°C; and at depths of 10; 000 meters.

  5. Smart Meter Security Infrastructure: Some Observations

    E-Print Network [OSTI]

    Ladkin, Peter B.

    , access Smart Grid nodes via the Smart Meter, or pretend electricity use that is other than the actual use companies must prepare for large scale failure of Smart Grid nodes. There must be fallback strategies if there are no special precautions that isolate Smart Grid nodes from compromised nodes. To clean a compromised Smart

  6. Laser Power Meter Large, bright, backlit LCD

    E-Print Network [OSTI]

    Woodall, Jerry M.

    Laser Power Meter FEATURES · Large, bright, backlit LCD display · Digital accuracy with analog-like movement for laser tuning · Works with thermopile and optical sensors · Intuitive button-driven user COMPATIBILITY · PowerMax® thermal sensors · Optical sensors FieldMaxII-TO Coherent Laser Measurement and Control

  7. The economics of net metering Larry Hughes

    E-Print Network [OSTI]

    Hughes, Larry

    . In jurisdictions that permit net metering, the owners of these facilities (the customer-generators) can supply of financial compensation on the selection of generation equipment from the perspective of the customer that generate electricity intermittently (typically renewables such as wind and solar) need not be concerned

  8. Hardware Metering: A Survey Farinaz Koushanfar

    E-Print Network [OSTI]

    , the problem has recently gained an increased attention by the industry, government, and research community passive and active hardware metering methods available. Electrical and Computer Engineering Department only be performed in state-of-art fabrication facilities. Building or maintaining such facilities

  9. Energy Theft in the Advanced Metering Infrastructure

    E-Print Network [OSTI]

    McDaniel, Patrick Drew

    , with this infrastructure comes new risk. In this paper, we consider ad- versary means of defrauding the electrical gridEnergy Theft in the Advanced Metering Infrastructure Stephen McLaughlin, Dmitry Podkuiko, and Patrick McDaniel Systems and Internet Infrastructure Security Laboratory (SIIS) Pennsylvania State

  10. Smart Meter Company Boosting Production, Workforce

    Broader source: Energy.gov [DOE]

    A manufacturing facility in South Carolina is producing enough smart meters to reduce annual electricity use by approximately 1.7 million megawatt hours -- and through advanced manufacturing tax credits, just increased the facility's production capability by 20 percent and created 420 jobs.

  11. NATL Grid Map 50-Meter Grid

    E-Print Network [OSTI]

    Slatton, Clint

    NATL-east NATL Grid Map 50-Meter Grid Locations in NATL can be specified by reference to a grid intervals. Each gridline intersection ("grid point") is identified by its two gridlines (e.g., E5). Each 50x50-m block formed by the gridlines is identified by the grid point in its northwest corner (e

  12. 2011 W. Meyer Qualifizierungsbedarf Smart Metering

    E-Print Network [OSTI]

    Ulm, Universität

    1 2011 W. Meyer Qualifizierungsbedarf Smart Metering Qualifizierungsbedarf im Bereich Smart Netze und E - Mobility Willi Meyer Zentrum für Elektro- und Schulungsleiter Informationstechnik Nürnberg #12;2 2011 W. Meyer Alle Angaben wurden mit Sorgfalt und nach bestem Wissen und Gewissen erstellt. Es

  13. Ash level meter for a fixed-bed coal gasifier

    DOE Patents [OSTI]

    Fasching, George E. (Morgantown, WV)

    1984-01-01T23:59:59.000Z

    An ash level meter for a fixed-bed coal gasifier is provided which utilizes the known ash level temperature profile to monitor the ash bed level. A bed stirrer which travels up and down through the extent of the bed ash level is modified by installing thermocouples to measure the bed temperature as the stirrer travels through the stirring cycle. The temperature measurement signals are transmitted to an electronic signal process system by an FM/FM telemetry system. The processing system uses the temperature signals together with an analog stirrer position signal, taken from a position transducer disposed to measure the stirrer position to compute the vertical location of the ash zone upper boundary. The circuit determines the fraction of each total stirrer cycle time the stirrer-derived bed temperature is below a selected set point, multiplies this fraction by the average stirrer signal level, multiplies this result by an appropriate constant and adds another constant such that a 1 to 5 volt signal from the processor corresponds to a 0 to 30 inch span of the ash upper boundary level. Three individual counters in the processor store clock counts that are representative of: (1) the time the stirrer temperature is below the set point (500.degree. F.), (2) the time duration of the corresponding stirrer travel cycle, and (3) the corresponding average stirrer vertical position. The inputs to all three counters are disconnected during any period that the stirrer is stopped, eliminating corruption of the measurement by stirrer stoppage.

  14. Development of the prototype Munitions Case Moisture Meter, Model ORNL-1. Final report

    SciTech Connect (OSTI)

    Agouridis, D.C.; Gayle, T.M.; Griest, W.H.

    1993-02-24T23:59:59.000Z

    There is a great need for a rapid and simple means of determining the moisture content in combustible cartridge case (ccc) munitions. Previous studies have demonstrated that accumulation of moisture in ccc rounds, such as the M829, leads to softening of the case wall and weakening of the adhesive joint. Moisture in the ccc can lead to incomplete combustion of the case upon firing the round. Currently, there are no facile methods for measuring the moisture content. A prototype portable meter for non-destructive and rapid estimation of moisture in ccc has been developed. The Munitions Case Moisture Meter Model ORNL-1 demonstrates the feasibility of developing an instrument based on the moisture dependence of dielectric properties, to measure moisture in ccc munitions in storage and in the field. These instruments are simple, inexpensive, lightweight, portable, low-power battery operated, and intrinsically safe. They provide nondestructive, noninvasive, and rapid measurements. Calibration data for the prototype are not available at this time. Therefore, calibration of the meter and the development of a scale reading directly moisture content in munitions rounds could not be completed. These data will be supplied by the US Army from its tests of the meter with actual munitions. However, experimental results on empty cccs in laboratory conditions demonstrate satisfactory performance of the instrument. Additional work is needed to bring the prototype to its optimum usefulness and accuracy for field measurements. This includes: Calibration of the meter scale with full-up munitions; Data and evaluation procedures to adjust the performance of the meter for different environmental conditions such as temperature and humidity; and Studies of the dielectric properties of moist ccc materials, as a function of frequency and temperature, are needed for adjustment of the meter for optimal performance.

  15. Development of the prototype Munitions Case Moisture Meter, Model ORNL-1

    SciTech Connect (OSTI)

    Agouridis, D.C.; Gayle, T.M.; Griest, W.H.

    1993-02-24T23:59:59.000Z

    There is a great need for a rapid and simple means of determining the moisture content in combustible cartridge case (ccc) munitions. Previous studies have demonstrated that accumulation of moisture in ccc rounds, such as the M829, leads to softening of the case wall and weakening of the adhesive joint. Moisture in the ccc can lead to incomplete combustion of the case upon firing the round. Currently, there are no facile methods for measuring the moisture content. A prototype portable meter for non-destructive and rapid estimation of moisture in ccc has been developed. The Munitions Case Moisture Meter Model ORNL-1 demonstrates the feasibility of developing an instrument based on the moisture dependence of dielectric properties, to measure moisture in ccc munitions in storage and in the field. These instruments are simple, inexpensive, lightweight, portable, low-power battery operated, and intrinsically safe. They provide nondestructive, noninvasive, and rapid measurements. Calibration data for the prototype are not available at this time. Therefore, calibration of the meter and the development of a scale reading directly moisture content in munitions rounds could not be completed. These data will be supplied by the US Army from its tests of the meter with actual munitions. However, experimental results on empty cccs in laboratory conditions demonstrate satisfactory performance of the instrument. Additional work is needed to bring the prototype to its optimum usefulness and accuracy for field measurements. This includes: Calibration of the meter scale with full-up munitions; Data and evaluation procedures to adjust the performance of the meter for different environmental conditions such as temperature and humidity; and Studies of the dielectric properties of moist ccc materials, as a function of frequency and temperature, are needed for adjustment of the meter for optimal performance.

  16. analog fiber-optic links: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    meter to kilometer scales. Laboratory results demonstrate the feasibility of the heat pulse method implemented with fiber optic temperature sensing to obtain accurate distributed...

  17. Community Net Energy Metering: How Novel Policies Expand Benefits of Net Metering to Non-Generators

    SciTech Connect (OSTI)

    Rose, James; Varnado, Laurel

    2009-04-01T23:59:59.000Z

    As interest in community solutions to renewable energy grows, more states are beginning to develop policies that encourage properties with more than one meter to install shared renewable energy systems. State net metering policies are evolving to allow the aggregation of multiple meters on a customer���¢��������s property and to dissolve conventional geographical boundaries. This trend means net metering is expanding out of its traditional function as an enabling incentive to offset onsite customer load at a single facility. This paper analyzes community net energy metering (CNEM) as an emerging vehicle by which farmers, neighborhoods, and municipalities may more easily finance and reap the benefits of renewable energy. Specifically, it aims to compare and contrast the definition of geographical boundaries among different CNEM models and examine the benefits and limitations of each approach. As state policies begin to stretch the geographic boundaries of net metering, they allow inventive solutions to encourage renewable energy investment. This paper attempts to initiate the conversation on this emerging policy mechanism and offers recommendations for further development of these policies.

  18. Fuel cell membrane hydration and fluid metering

    DOE Patents [OSTI]

    Jones, Daniel O. (Glenville, NY); Walsh, Michael M. (Fairfield, CT)

    2003-01-01T23:59:59.000Z

    A hydration system includes fuel cell fluid flow plate(s) and injection port(s). Each plate has flow channel(s) with respective inlet(s) for receiving respective portion(s) of a given stream of reactant fluid for a fuel cell. Each injection port injects a portion of liquid water directly into its respective flow channel. This serves to hydrate at least corresponding part(s) of a given membrane of the corresponding fuel cell(s). The hydration system may be augmented by a metering system including flow regulator(s). Each flow regulator meters an injecting at inlet(s) of each plate of respective portions of liquid into respective portion(s) of a given stream of fluid by corresponding injection port(s).

  19. Fuel cell membrane hydration and fluid metering

    DOE Patents [OSTI]

    Jones, Daniel O. (Glenville, NY); Walsh, Michael M. (Fairfield, CT)

    1999-01-01T23:59:59.000Z

    A hydration system includes fuel cell fluid flow plate(s) and injection port(s). Each plate has flow channel(s) with respective inlet(s) for receiving respective portion(s) of a given stream of reactant fluid for a fuel cell. Each injection port injects a portion of liquid water directly into its respective flow channel in order to mix its respective portion of liquid water with the corresponding portion of the stream. This serves to hydrate at least corresponding part(s) of a given membrane of the corresponding fuel cell(s). The hydration system may be augmented by a metering system including flow regulator(s). Each flow regulator meters an injecting at inlet(s) of each plate of respective portions of liquid into respective portion(s) of a given stream of fluid by corresponding injection port(s).

  20. The Need for Essential Consumer Protections: Smart metering proposals...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    metering proposals and the move to time-based pricing. August 2010 The Need for Essential Consumer Protections: Smart metering proposals and the move to time-based pricing. August...

  1. Wireless Electricity Metering of Miscellaneous and Electronic Devices in Buildings

    E-Print Network [OSTI]

    Culler, David E.

    Wireless Electricity Metering of Miscellaneous and Electronic Devices in Buildings, University of California, Berkeley, USA Abstract- Miscellaneous and electronic devices hundreds of miscellaneous and electronic devices where metered for several months

  2. Author's personal copy Ramp metering and freeway bottleneck capacity

    E-Print Network [OSTI]

    Levinson, David M.

    ; Hall and Agyemang-Duah, 1991; Banks, 1991a,b). The two-capacity hypothesis argues that metering can

  3. Energy Secretary Chu Announces Five Million Smart Meters Installed...

    Office of Environmental Management (EM)

    metering infrastructure (AMI), distribution automation technologies, new electricity pricing programs, and advanced monitoring equipment for the transmission system. The goal...

  4. Optimal Privacy-Preserving Energy Management for Smart Meters

    E-Print Network [OSTI]

    Reisslein, Martin

    Optimal Privacy-Preserving Energy Management for Smart Meters Lei Yang, Xu Chen, Junshan Zhang Abstract--Smart meters, designed for information collection and system monitoring in smart grid, report a tradeoff between the smart meter data privacy and the electricity bill. In general, a major challenge

  5. Security and Smart Metering Sophia Kaplantzis and Y. Ahmet Sekercioglu

    E-Print Network [OSTI]

    Sekercioglu, Y. Ahmet

    Security and Smart Metering Sophia Kaplantzis and Y. Ahmet S¸ekercioglu Department of Electrical the transmission network, to the suppliers back office. It encompasses concepts such as smart metering, smart does this threat translate to smart metering applications? In this article, we focus on the security

  6. Privacy Preserving Smart Metering System Based Retail Level Electricity Market

    E-Print Network [OSTI]

    Franchetti, Franz

    1 Privacy Preserving Smart Metering System Based Retail Level Electricity Market Cory Thoma, Tao Cui, Student Member, IEEE, Franz Franchetti, Member, IEEE Abstract--Smart metering systems multi-party compu- tation (SMC) based privacy preserving smart metering system. Using the proposed SMC

  7. Secure Multiparty Computation Based Privacy Preserving Smart Metering System

    E-Print Network [OSTI]

    Franchetti, Franz

    Secure Multiparty Computation Based Privacy Preserving Smart Metering System Cory Thoma Information Ave. Pittsburgh, PA 15213 Email: {tcui,franzf}@ece.cmu.edu Abstract--Smart metering systems provide privacy preserving protocol for smart meter based load management. Using SMC and a proper designed

  8. Smart Meter Aware Domestic Energy Trading Agents Nicola Capodieci

    E-Print Network [OSTI]

    Aiello, Marco

    Smart Meter Aware Domestic Energy Trading Agents Nicola Capodieci University of Modena and RE illustrate an implementation includ- ing the interfacing with a physical Smart Meter and provide initial--Intelligent agents, Multiagent systems General Terms Design, Economy Keywords Energy trade, agents, smart meter 1

  9. Leveraging smart meter data to recognize home appliances Markus Weiss+#

    E-Print Network [OSTI]

    Leveraging smart meter data to recognize home appliances Markus Weiss+# , Adrian Helfenstein -- The worldwide adoption of smart meters that measure and communicate residential electricity consumption gives demand. In this paper we present an infrastructure and a set of algorithms that make use of smart meters

  10. Security Architecture of Smart Metering Systems Natasa Zivic1

    E-Print Network [OSTI]

    Boyer, Edmond

    Security Architecture of Smart Metering Systems Natasa Zivic1 and Christoph Ruland1 1 University.Zivic, Christoph.Ruland}@uni-siegen.de Abstract. The main goals of smart metering are the reduction of costs dynamically the power generation and distribution to the requested energy by smart grids. Metering devices

  11. Smart-Metering for Monitoring Building Power Distribution Network using Instantaneous Phasor Computations of Electrical Signals

    E-Print Network [OSTI]

    K.R., Krishnanand

    2013-01-01T23:59:59.000Z

    efficient operation of a smart meter network . in IndustrialGood standards for smart meters . in European EnergyHardware development for Smart Meter based innovations . in

  12. Widget:GoalMeter | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to:Ezfeedflag JumpID-fTri GlobalJump to:WestwoodCreatePageFormFieldsDisplayToggleGoalMeter Jump

  13. 2010 Smart Meter Installations | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently20,000 Russian NuclearandJune 17, 2015 SEABOnlyTipsWorkingErichsecurity10 Smart Meter

  14. greenMeter | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells, Wisconsin: EnergyWyandanch,Eaga SolarZoloHome Dc'scloudgridgreenMeter

  15. Power Metering Project | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMay 2015 < prev next > Sun Mon Tue Wed May 28-29,Metering Project Power

  16. Long Island Smart Metering Pilot Project

    SciTech Connect (OSTI)

    None

    2012-03-30T23:59:59.000Z

    The Long Island Power Authority (LIPA) Smart Meter Pilots provided invaluable information and experience for future deployments of Advanced Metering Infrastructure (AMI), including the deployment planned as part of LIPAâ??s Smart Grid Demonstration Project (DE-OE0000220). LIPA will incorporate lessons learned from this pilot in future deployments, including lessons relating to equipment performance specifications and testing, as well as equipment deployment and tracking issues. LIPA ultimately deployed three AMI technologies instead of the two that were originally contemplated. This enabled LIPA to evaluate multiple systems in field conditions with a relatively small number of meter installations. LIPA experienced a number of equipment and software issues that it did not anticipate, including issues relating to equipment integration, ability to upgrade firmware and software â??over the airâ? (as opposed to physically interacting with every meter), and logistical challenges associated with tracking inventory and upgrade status of deployed meters. In addition to evaluating the technology, LIPA also piloted new Time-of-Use (TOU) rates to assess customer acceptance of time-differentiated pricing and to evaluate whether customers would respond by adjusting their activities from peak to non-peak periods. LIPA developed a marketing program to educate customers who received AMI in the pilot areas and to seek voluntary participation in TOU pricing. LIPA also guaranteed participating customers that, for their initial year on the rates, their electricity costs under the TOU rate would not exceed the amount they would have paid under the flat rates they would otherwise enjoy. 62 residential customers chose to participate in the TOU rates, and every one of them saved money during the first year. 61 of them also elected to stay on the TOU rate â?? without the cost guarantee â?? at the end of that year. The customer who chose not to continue on the rate was also the one who achieved the greatest savings. However, after the first year, the customer in question installed equipment that would have made TOU rates a more costly option than the residential flat rate. During the second year, all but one customer saved money. That customer increased usage during peak hours, and as a result saw an increase in annual costs (as compared to the flat rate) of $24.17. The results were less clear for commercial customers, which LIPA attributes to rate design issues that it will take into account for future deployments. LIPA views this pilot as a complete success. Not only is LIPA better prepared for a larger deployment of AMI, but it is confident that residential customers will accept AMI and TOU rates and shift their energy consumption from peak to non-peak periods in response to pricing. On a larger scale, this will benefit LIPA and all of its customers by potentially lowering peak demand when energy costs are highest.

  17. Method and apparatus for reading meters from a video image

    DOE Patents [OSTI]

    Lewis, Trevor J. (Irwin, PA); Ferguson, Jeffrey J. (North Huntingdon, PA)

    1997-01-01T23:59:59.000Z

    A method and system to enable acquisition of data about an environment from one or more meters using video images. One or more meters are imaged by a video camera and the video signal is digitized. Then, each region of the digital image which corresponds to the indicator of the meter is calibrated and the video signal is analyzed to determine the value indicated by each meter indicator. Finally, from the value indicated by each meter indicator in the calibrated region, a meter reading is generated. The method and system offer the advantages of automatic data collection in a relatively non-intrusive manner without making any complicated or expensive electronic connections, and without requiring intensive manpower.

  18. Thirty Meter Telescope Detailed Science Case: 2015

    E-Print Network [OSTI]

    Skidmore, Warren; Fukugawa, Misato; Goswami, Aruna; Hao, Lei; Jewitt, David; Laughlin, Greg; Steidel, Charles; Hickson, Paul; Simard, Luc; Schöck, Matthias; Treu, Tommaso; Cohen, Judith; Anupama, G C; Dickinson, Mark; Harrison, Fiona; Kodama, Tadayuki; Lu, Jessica R; Macintosh, Bruce; Malkan, Matt; Mao, Shude; Narita, Norio; Sekiguchi, Tomohiko; Subramaniam, Annapurni; Tanaka, Masaomi; Tian, Feng; A'Hearn, Michael; Akiyama, Masayuki; Ali, Babar; Aoki, Wako; Bagchi, Manjari; Barth, Aaron; Bhalerao, Varun; Bradac, Marusa; Bullock, James; Burgasser, Adam J; Chapman, Scott; Chary, Ranga-Ram; Chiba, Masashi; Cooray, Asantha; Crossfield, Ian; Currie, Thayne; Das, Mousumi; Dewangan, G C; de Grijs, Richard; Do, Tuan; Dong, Subo; Evslin, Jarah; Fang, Taotao; Fang, Xuan; Fassnacht, Christopher; Fletcher, Leigh; Gaidos, Eric; Gal, Roy; Ghez, Andrea; Giavalisco, Mauro; Grady, Carol A; Greathouse, Thomas; Gogoi, Rupjyoti; Guhathakurta, Puragra; Ho, Luis; Hasan, Priya; Herczeg, Gregory J; Honda, Mitsuhiko; Imanishi, Masa; Inanmi, Hanae; Iye, Masanori; Kamath, U S; Kane, Stephen; Kashikawa, Nobunari; Kasliwal, Mansi; Kirby, Vishal KasliwalEvan; Konopacky, Quinn M; Lepine, Sebastien; Li, Di; Li, Jianyang; Liu, Junjun; Liu, Michael C; Lopez-Rodriguez, Enrigue; Lotz, Jennifer; Lubin, Philip; Macri, Lucas; Maeda, Keiichi; Marchis, Franck; Marois, Christian; Marscher, Alan; Martin, Crystal; Matsuo, Taro; Max, Claire; McConnachie, Alan; McGough, Stacy; Melis, Carl; Meyer, Leo; Mumma, Michael; Muto, Takayuki; Nagao, Tohru; Najita, Joan R; Navarro, Julio; Pierce, Michael; Prochaska, Jason X; Oguri, Masamune; Ojha, Devendra K; Okamoto, Yoshiko K; Orton, Glenn; Otarola, Angel; Ouchi, Masami; Packham, Chris; Padgett, Deborah L; Pandey, Shashi Bhushan; Pilachowsky, Catherine; Pontoppidan, Klaus M; Primack, Joel; Puthiyaveettil, Shalima; Ramirez-Ruiz, Enrico; Reddy, Naveen; Rich, Michael; Richter, Matthew J; Schombert, James; Sen, Anjan Ananda; Shi, Jianrong; Sheth, Kartik; Srianand, R; Tan, Jonathan C; Tanaka, Masayuki; Tanner, Angelle; Tominaga, Nozomu; Tytler, David; U, Vivian; Wang, Lingzhi; Wang, Xiaofeng; Wang, Yiping; Wilson, Gillian; Wright, Shelley; Wu, Chao; Wu, Xufeng; Xu, Renxin; Yamada, Toru; Yang, Bin; Zhao, Gongbo; Zhao, Hongsheng

    2015-01-01T23:59:59.000Z

    The TMT Detailed Science Case describes the transformational science that the Thirty Meter Telescope will enable. Planned to begin science operations in 2024, TMT will open up opportunities for revolutionary discoveries in essentially every field of astronomy, astrophysics and cosmology, seeing much fainter objects much more clearly than existing telescopes. Per this capability, TMT's science agenda fills all of space and time, from nearby comets and asteroids, to exoplanets, to the most distant galaxies, and all the way back to the very first sources of light in the Universe. More than 150 astronomers from within the TMT partnership and beyond offered input in compiling the new 2015 Detailed Science Case. The contributing astronomers represent the entire TMT partnership, including the California Institute of Technology (Caltech), the Indian Institute of Astrophysics (IIA), the National Astronomical Observatories of the Chinese Academy of Sciences (NAOC), the National Astronomical Observatory of Japan (NAOJ),...

  19. Smart Metering and Electricity Demand: Technology, Economics and International Experience

    E-Print Network [OSTI]

    Brophy Haney, A; Jamasb, Tooraj; Pollitt, Michael G.

    www.eprg.group.cam.ac.uk E P R G W O R K IN G P A P E R Abstract Smart Metering and Electricity Demand: Technology, Economics and International Experience EPRG Working Paper EPRG0903 Cambridge Working Paper in Economics 0905 Aoife... Brophy Haney, Tooraj Jamasb and Michael G. Pollitt In recent years smart metering of electricity demand has attracted attention around the world. A number of countries and regions have started deploying new metering systems; and many others have...

  20. Non-invasive energy meter for fixed and variable flow systems

    DOE Patents [OSTI]

    Menicucci, David F.; Black, Billy D.

    2005-11-01T23:59:59.000Z

    An energy metering method and apparatus for liquid flow systems comprising first and second segments of one or more conduits through which a liquid flows, comprising: attaching a first temperature sensor for connection to an outside of the first conduit segment; attaching a second temperature sensor for connection to an outside of the second conduit segment; via a programmable control unit, receiving data from the sensors and calculating energy data therefrom; and communicating energy data from the meter; whereby the method and apparatus operate without need to temporarily disconnect or alter the first or second conduit segments. The invention operates with both variable and fixed flow systems, and is especially useful for both active and passive solar energy systems.

  1. Optimization Online - A Security Framework for Smart Metering with ...

    E-Print Network [OSTI]

    Cristina Rottondi

    2011-12-05T23:59:59.000Z

    Dec 5, 2011 ... Abstract: The increasing diffusion of Automatic Meter Reading (AMR) has raised many concerns about the protection of personal data related to ...

  2. Hydro-Québec Net Metering (Quebec, Canada) | Open Energy Information

    Open Energy Info (EERE)

    Canada) Policy Type Net Metering Affected Technologies Geothermal Electric, Solar Photovoltaics Active Policy Yes Implementing Sector Utility Funding Source Hydro-Quebec Primary...

  3. The Intersection of Net Metering and Retail Choice: An Overview...

    Energy Savers [EERE]

    and utilities provide net metering options for their customers. They then provided case studies to illustrate the models. Date December 2010 Topic Financing, Incentives &...

  4. Wavelength meter having single mode fiber optics multiplexed inputs

    DOE Patents [OSTI]

    Hackel, Richard P. (Livermore, CA); Paris, Robert D. (San Ramon, CA); Feldman, Mark (Pleasanton, CA)

    1993-01-01T23:59:59.000Z

    A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

  5. Wavelength meter having single mode fiber optics multiplexed inputs

    DOE Patents [OSTI]

    Hackel, R.P.; Paris, R.D.; Feldman, M.

    1993-02-23T23:59:59.000Z

    A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

  6. Scotia Energy Electricity- Net Metering Program (Nova Scotia, Canada)

    Broader source: Energy.gov [DOE]

    Nova Scotia Power Inc. Net Metering allows residential and commercial customers to connect small, renewable energy generating units to the provincial power grid.

  7. Maritime Electric- Net Metering (Prince Edward Island, Canada)

    Broader source: Energy.gov [DOE]

    In December 2005 The Renewable Energy Act and associated Regulations came into effect. A Government policy objective incorporated in the Act was the introduction of net metering for...

  8. Cost benefit analysis for the implementation of smart metering...

    Open Energy Info (EERE)

    Smart Grid Projects Smart Grid Projects in Europe Smart Grid Projects - Smart Meter and AMI Smart Grid Projects - Home application Smart Grid Projects - Customer Behavior...

  9. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    E-Print Network [OSTI]

    Darghouth, Naim Richard

    2013-01-01T23:59:59.000Z

    Study: The Economic Cost of Net-Metering in Maryland: WhoEnergy (DSIRE), 2010. Map of Net Metering Policies [WWWdocuments/summarymaps/Net_Metering_map.ppt De Jonghe, C. ,

  10. Electrical energy metering application at a large research facility

    SciTech Connect (OSTI)

    Falke, S.S.

    1991-05-08T23:59:59.000Z

    A brief history of electric energy metering at Lawrence Livermore National Laboratory is presented. Use of electromechanical watthour demand, solid state single function transducers, analog multifunction, and digital multifunction per-phase metering are discussed. Applications for interdepartment revenue transfer based on energy and power flow, load profiling, system planning, and use as a troubleshooting tool are described. 6 refs.

  11. A Global Personal Energy Meter University of Cambridge Computer Laboratory

    E-Print Network [OSTI]

    Cambridge, University of

    - sumption figures scaled by a predetermined factor for the type of energy used and divided equally amongstA Global Personal Energy Meter Simon Hay University of Cambridge Computer Laboratory Abstract of goods and provision of services. I envisage a personal energy meter which can record and apportion

  12. Solid state watt-hour meter

    SciTech Connect (OSTI)

    Hurley, J.R.; Gilker, C.S.

    1984-08-21T23:59:59.000Z

    A watt-hour meter is disclosed which includes: a microprocessor coupled to a solid-state Hall-Effect sensor; an electrically alterable ROM coupled to the microprocessor; a power supply; a power outage timing means using the discharge characteristic of a capacitor; apparatus for supplying a 60 Hz clock signal to the microprocessor; a readout device coupled to the microprocessor to provide an indication of the power consumed; an output on the microprocessor for controlling a circuit breaker; and a switch for overriding the microprocessor controlled circuit breaker. The microprocessor and the electrically alterable ROM are connected and programmed: to sense the time of day as determined from an initial time of day and setting the 60 Hz clock signal; to sense and compute the power used by the consumer; to automatically open the circuit breaker when power demand on the electric power source is high and/or the cost per kilowatt hour is high; to automatically close the circuit breaker when the power demand on the source of electric power is low and/or the cost per kilowatt power is low; and to allow a consumer to override the microprocessor's control of the circuit breaker.

  13. Embedded Firmware Diversity for Smart Electric Meters Stephen McLaughlin, Dmitry Podkuiko, Adam Delozier

    E-Print Network [OSTI]

    McDaniel, Patrick Drew

    Embedded Firmware Diversity for Smart Electric Meters Stephen McLaughlin, Dmitry Podkuiko, Adam}@cse.psu.edu Abstract Smart meters are now being aggressively deployed world- wide, with tens of millions of meters- niques can limit large-scale attacks on smart meters. We show how current meter designs do not possess

  14. Gas energy meter for inferential determination of thermophysical properties of a gas mixture at multiple states of the gas

    DOE Patents [OSTI]

    Morrow, Thomas B. (San Antonio, TX); Kelner, Eric (San Antonio, TX); Owen, Thomas E. (Helotes, TX)

    2008-07-08T23:59:59.000Z

    A gas energy meter that acquires the data and performs the processing for an inferential determination of one or more gas properties, such as heating value, molecular weight, or density. The meter has a sensor module that acquires temperature, pressure, CO2, and speed of sound data. Data is acquired at two different states of the gas, which eliminates the need to determine the concentration of nitrogen in the gas. A processing module receives this data and uses it to perform a "two-state" inferential algorithm.

  15. Development Of 2-Meter Soil Temperature Probes And Results Of Temperature

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOE Facility DatabaseMichigan: EnergyKansas:Detroit Beach,SouthDiversifiedSurvey

  16. Electrical energy metering use at a large research facility

    SciTech Connect (OSTI)

    Falke, S.S.

    1992-01-01T23:59:59.000Z

    A brief history of electric energy metering at a large research laboratory is presented. Limited orientation on metering of power and energy quantities derived from single dimension magnitudes is introduced. Operation and application of electromechanical watthour demand, solid state single function transducers, analog multifunction, and digital multifunction discussed. Applications for interdepartmental revenue transfer based on energy and power flow, load profiling, system planning, and use as a troubleshooting tool are described. The material is presented in a perspective for persons familiar with protective relaying components, but lacking similar experience in energy metering.

  17. Power Challenges of Large Scale Research Infrastructures: the Square Kilometer Array and Solar Energy Integration; Towards a zero-carbon footprint next generation telescope

    E-Print Network [OSTI]

    Barbosa, Domingos; Ruiz, Valeriano; Silva, Manuel; Verdes-Montenegro, Lourdes; Santander-Vela, Juande; Maia, Dalmiro; Antón, Sonia; van Ardenne, Arnold; Vetter, Matthias; Kramer, Michael; Keller, Reinhard; Pereira, Nuno; Silva, Vitor

    2012-01-01T23:59:59.000Z

    The Square Kilometer Array (SKA) will be the largest Global science project of the next two decades. It will encompass a sensor network dedicated to radioastronomy, covering two continents. It will be constructed in remote areas of South Africa and Australia, spreading over 3000Km, in high solar irradiance latitudes. Solar Power supply is therefore an option to power supply the SKA and contribute to a zero carbon footprint next generation telescope. Here we outline the major characteristics of the SKA and some innovation approaches on thermal solar energy Integration with SKA prototypes.

  18. Insights from Smart Meters: The Potential for Peak-Hour Savings from Behavior-Based Programs

    E-Print Network [OSTI]

    Todd, Annika

    2014-01-01T23:59:59.000Z

    2014.  Insights from Smart  Meters: The Potential for Peak available data captured by smart meters and other sources,series Insights from Smart Meters. DRAFT – DO NOT CIRCULATE

  19. NREL: Energy Storage - BLAST for Behind-the-Meter Applications...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lite (BLAST-BTM Lite) provides a quick, user-friendly tool to size behind-the-meter energy storage devices used on site by utility customers for facility demand charge...

  20. Smart Meters Offer 'Instant Gratification;' Help Houston Homeowners...

    Broader source: Energy.gov (indexed) [DOE]

    Diorio explains to KPRC Local 2 News how much she's saved with her recently installed smart meter, which allows her to see her savings in real time. Houston resident Ruth...

  1. Demand Response and Smart Metering Policy Actions Since the Energy...

    Broader source: Energy.gov (indexed) [DOE]

    This report represents a review of policy developments on demand response and other related areas such as smart meters and smart grid. It has been prepared by the Demand Response...

  2. ODUSD (I&E) Facilities Energy Program Advanced Metering Policy

    Broader source: Energy.gov [DOE]

    Presentation—given at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meeting—covers the U.S. Department of Defense's (DoD's) metering policy, including implementation challenges and utility partnerships.

  3. Smart Meters Helping Oklahoma Consumers Save Hundreds During...

    Broader source: Energy.gov (indexed) [DOE]

    meters give consumers real-time information on how their energy use affects their energy costs. With a two-tiered pricing system, you get a discount during lower usage...

  4. Down to the Meter: Localized Vehicle Pollution Matters

    E-Print Network [OSTI]

    Houston, Douglas; Wu, Jun; Ong, Paul; Winer, Arthur

    2006-01-01T23:59:59.000Z

    Near-Roadway Vehicle Pollution,” American Journal of Publicfor Vehicle-Related Air Pollution Exposure in Minority andMeter: Localized Vehicle Pollution Matters B Y D O U G L A S

  5. 25 years ago: the official farewell to the meter

    E-Print Network [OSTI]

    Thomas Schucker

    2008-10-20T23:59:59.000Z

    On october 21st 1983 took place in S\\`evres on the western outskirts of Paris the official funeral of the meter. With it the notion of distance as a physical observable was buried.

  6. Value creation and value capture of advanced electricity meter information

    E-Print Network [OSTI]

    Oesterlin, Ulf

    2011-01-01T23:59:59.000Z

    Advanced or smart metering has been a hot topic in the electricity community for several years. Despite the excitement about the technology, few business cases are actually able to justify the investment cost. One reason ...

  7. advanced metering techniques: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Assessment of Demand Response and Advanced Metering Power Transmission, Distribution and Plants Websites...

  8. Shared Signals: Using Existing Facility Meters for Energy Savings Verification

    E-Print Network [OSTI]

    McBride, J. R.; Bohmer, C. J.; Price, S. D.; Carlson, K.; Lopez, J.

    of metering. Facility engineers wonder whether existing meters can be used for savings verification purposes. They want to know whether an existing energy management and control system (EMCS) can serve double duty and be used for savings verification... an existing EMCS for energy savings verification purposes is even more complex. While at first glance the idea of using an existing EMCS for energy savings verification purposes seems absolutely reasonable, the practicality of the situation must...

  9. Smart-Metering for Monitoring Building Power Distribution Network using Instantaneous Phasor Computations of Electrical Signals

    E-Print Network [OSTI]

    K.R., Krishnanand

    2013-01-01T23:59:59.000Z

    Smart-Metering for Monitoring Building Power Distributionimplementable for smart-meters for a building. Eachcontrol node of a building so as to make smart decisions.

  10. Plasma momentum meter for momentum flux measurements

    DOE Patents [OSTI]

    Zonca, Fulvio (Rome, IT); Cohen, Samuel A. (Hopewell, NJ); Bennett, Timothy (Princeton, NJ); Timberlake, John R. (Allentown, NJ)

    1993-01-01T23:59:59.000Z

    Invention comprises an instrument in which momentum flux onto a biasable target plate is transferred via a suspended quartz tube onto a sensitive force transducer--a capacitance-type pressure gauge. The transducer is protected from thermal damage, arcing and sputtering, and materials used in the target and pendulum are electrically insulating, rigid even at elevated temperatures, and have low thermal conductivity. The instrument enables measurement of small forces (10.sup.-5 to 10.sup.3 N) accompanied by high heat fluxes which are transmitted by energetic particles with 10's of eV of kinetic energy in a intense magnetic field and pulsed plasma environment.

  11. Plug-in privacy for Smart Metering billing

    E-Print Network [OSTI]

    Jawurek, Marek; Kerschbaum, Florian

    2010-01-01T23:59:59.000Z

    Smart Metering is a concept that allows to collect fine-grained consumption profiles from customers by replacing traditional electricity meters with Smart Meters in customers' households. The recorded consumption profile is the basis for the calculation of time-dependent tariffs but also allows deduction of the inhabitant's personal schedules and habits. The current reporting of such consumption profiles only protects this data from 3rd parties but falls short to protect the customer's privacy from illegitimate abuse by the supplier itself. We propose a privacy-preserving profile reporting protocol that enables billing for time-dependent tariffs without disclosing the actual data of the consumption profile to the supplier. Our approach relies on a zero-knowledge proof based on Pedersen Commitments performed by a plug-in privacy component that is put into the communication link between Smart Meter and supplier's back-end systems and requires no change to Smart Meter hardware and only little change to the softw...

  12. Differentially Private Smart Metering with Battery Michael Backes1,2

    E-Print Network [OSTI]

    Differentially Private Smart Metering with Battery Recharging Michael Backes1,2 and Sebastian meters to take fine-grained readings of energy usage. These smart meters enable flexible time- of to a min- imum. 1 Introduction The energy industry has recently begun using smart meters to take fine

  13. Survivable Smart Grid Communication: Smart-Meters Meshes to the Rescue

    E-Print Network [OSTI]

    Tague, Patrick

    Survivable Smart Grid Communication: Smart-Meters Meshes to the Rescue Arjun P. Athreya and Patrick flattening process. This process involves smart-meters and other disaster surviving elements of higher system as a function of outage area, smart-meter density and smart-meter's neighborhood size. The results from

  14. Advanced Metering Implementations - A Perspective from Federal Sector

    SciTech Connect (OSTI)

    Eaarni, Shankar

    2014-08-11T23:59:59.000Z

    Federal mandate (EPACT 2005) requires that federal buildings install advanced electrical meters-meters capable of providing data at least daily and measuring the consumption of electricity at least hourly. This work presents selected advanced metering implementations to understand some of the existing practices related to data capture and to understand how the data is being translated into information and knowledge that can be used to improve building energy and operational performance to meet federal energy reduction mandates. This study highlights case studies to represent some of the various actions that are being taken based on the data that are being collected to improve overall energy performance of these buildings. Some of these actions include- individualized tenant billing and energy forecasting, benchmarking, identifying energy conservation measures, measurement and verification.

  15. Net Metering and Interconnection Procedures-- Incorporating Best Practices

    SciTech Connect (OSTI)

    Jason Keyes, Kevin Fox, Joseph Wiedman, Staff at North Carolina Solar Center

    2009-04-01T23:59:59.000Z

    State utility commissions and utilities themselves are actively developing and revising their procedures for the interconnection and net metering of distributed generation. However, the procedures most often used by regulators and utilities as models have not been updated in the past three years, in which time most of the distributed solar facilities in the United States have been installed. In that period, the Interstate Renewable Energy Council (IREC) has been a participant in more than thirty state utility commission rulemakings regarding interconnection and net metering of distributed generation. With the knowledge gained from this experience, IREC has updated its model procedures to incorporate current best practices. This paper presents the most significant changes made to IREC���¢��������s model interconnection and net metering procedures.

  16. Entropy Meters and the Entropy of Non-extensive Systems

    E-Print Network [OSTI]

    Elliott H. Lieb; Jakob Yngvason

    2014-03-30T23:59:59.000Z

    In our derivation of the second law of thermodynamics from the relation of adiabatic accessibility of equilibrium states we stressed the importance of being able to scale a system's size without changing its intrinsic properties. This leaves open the question of defining the entropy of macroscopic, but unscalable systems, such as gravitating bodies or systems where surface effects are important. We show here how the problem can be overcome, in principle, with the aid of an `entropy meter'. An entropy meter can also be used to determine entropy functions for non-equilibrium states and mesoscopic systems.

  17. Smart Meters and a Smarter Grid | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently AskedEnergyIssues DOE's Nuclear EnergySmart Meters and a Smarter Grid Smart Meters

  18. Metering and the New Federal Requirements of Energy Policy Act 2005

    E-Print Network [OSTI]

    Ream, A.; Verdict, M.

    2006-01-01T23:59:59.000Z

    agencies to meter electricity use in all federal buildings by Oct. 1, 2012 using advanced meters or metering devices that provide data at least daily. Six months after the enactment of EPAct, DOE’s Federal Energy Management Program, or FEMP... Station, Texas ABSTRACT Section 103 of the Energy Policy Act of 2005 (EPAct 2005) (1) mandates the installation of meters and advanced electric meters on all Federal Buildings by 2012 using guidelines developed by the US Department of Energy...

  19. VISITOR PARKING Pay station parking meters are available around

    E-Print Network [OSTI]

    temporary parking needs. Daily scratch-off permits are available in advance from Parking Services. LOT METER PAY STATION RATES (SUMMER RATES MAY BE DISCOUNTED) HOW DO I GET A PERMIT? When parking on campus, a CSM parking permit is required Monday through Friday, from 7AM until 5 PM. Permits authorize parking

  20. Privacy-friendly Energy-metering via Homomorphic Encryption

    E-Print Network [OSTI]

    Jacobs, Bart

    Privacy-friendly Energy-metering via Homomorphic Encryption Flavio D. Garcia and Bart Jacobs and consumption is one of the goals. Accurate usage data is important for such a better match. So-called smart by the utility sector. For instance, in April 2009 the Senate in the Netherlands has refused to pass a bill

  1. Grain Drill Metering Systems and the Need for Calibration

    E-Print Network [OSTI]

    Holland, Jeffrey

    Grain Drill Metering Systems and the Need for Calibration Purdue extension ABE-126-W Purdue down an average seed- ing rate. Calibration is often overlooked as a means of im- proving machine performance and controlling input costs. Calibration is simply the process of verifying the rate of delivery

  2. Hydrostatic bearings for a turbine fluid flow metering device

    DOE Patents [OSTI]

    Fincke, James R. (Rigby, ID)

    1982-01-01T23:59:59.000Z

    A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion.

  3. Embedded Cyber-Physical Anomaly Detection in Smart Meters

    E-Print Network [OSTI]

    vulnerabilities that arise from deployment of local cyber-physical attacks at a smart metering location and physical domains. 1 Introduction Limitations of today's power networks, combined with the need we address the risk of manipula- tions at the end-user level, even when a trusted infrastructure

  4. Securing Energy Metering Software with Automatic Source Code Correction

    E-Print Network [OSTI]

    Neves, Nuno

    of energy production have been fostering the monitoring and analy- sis of electricity consumption for the country [7]. Many of the meters provide energy consumption informa- tion that can be stored and processed in graphical format, analyze consumption trends, identify peak demand, and raise alarms about anomalous

  5. Hydrostatic bearings for a turbine fluid flow metering device

    DOE Patents [OSTI]

    Fincke, J.R.

    1982-05-04T23:59:59.000Z

    A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion. 3 figs.

  6. Using Wireless Power Meters to Measure Energy Use of

    E-Print Network [OSTI]

    Culler, David E.

    by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Technology Development, Building-term energy used by a large sample of devices due to the difficulty and expense of collecting deviceUsing Wireless Power Meters to Measure Energy Use of Miscellaneous and Electronic Devices

  7. Personal energy metering Simon Hay, Andrew Rice and Andy Hopper

    E-Print Network [OSTI]

    Cambridge, University of

    is true of energy consumption in shared buildings: in a house of four where all bills are split systems installed in many buildings today can be used to apportion energy consumption between users energy meter is a low cost, low infras- tructure location system that can be deployed on a truly global

  8. The Square Kilometer Array Interferometer

    E-Print Network [OSTI]

    Robert Braun

    1995-12-11T23:59:59.000Z

    The scientific motivation is reviewed for a next generation radio observatory operating at frequencies between about 200 MHz and 2 GHz with about 2 orders of magnitude greater sensitivity than that which is currently available, together with sub-arcsecond angular resolution. Instrumental concepts for the telescope are discussed, highlighting the role of mass produced receiver elements and digital electronics in increasing cost-effectiveness while actively reducing the instrument's sensitivity to radio frequency interference.

  9. Dead-time compensation for a logarithmic display rate meter

    DOE Patents [OSTI]

    Larson, John A. (Aurora, IL); Krueger, Frederick P. (Aurora, IL)

    1988-09-20T23:59:59.000Z

    An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events.

  10. Smart Meter Privacy: A Utility-Privacy Framework

    E-Print Network [OSTI]

    Rajagopalan, S Raj; Mohajer, Soheil; Poor, H Vincent

    2011-01-01T23:59:59.000Z

    End-user privacy in smart meter measurements is a well-known challenge in the smart grid. The solutions offered thus far have been tied to specific technologies such as batteries or assumptions on data usage. Existing solutions have also not quantified the loss of benefit (utility) that results from any such privacy-preserving approach. Using tools from information theory, a new framework is presented that abstracts both the privacy and the utility requirements of smart meter data. This leads to a novel privacy-utility tradeoff problem with minimal assumptions that is tractable. Specifically for a stationary Gaussian Markov model of the electricity load, it is shown that the optimal utility-and-privacy preserving solution requires filtering out frequency components that are low in power, and this approach appears to encompass most of the proposed privacy approaches.

  11. , Analysis of U.S. Net Metering and Interconnection Policy

    SciTech Connect (OSTI)

    Haynes, Rusty; Cook, Chris

    2006-07-01T23:59:59.000Z

    Historically, the absence of interconnection standards has been one of the primary barriers to the deployment of distributed generation (DG) in the United States. Although significant progress in the development of interconnection standards was achieved at both the federal and state levels in 2005, interconnection policy and net-metering policy continue to confound regulators, lawmakers, DG businesses, clean-energy advocates and consumers. For this reason it is critical to keep track of developments related to these issues. The North Carolina Solar Center (NCSC) is home to two Interstate Renewable Energy Council (IREC) projects -- the National Interconnection Project and the Database of State Incentives for Renewable Energy (DSIRE). This paper will present the major federal and state level policy developments in interconnection and net metering in 2005 and early 2006. It will also present conclusions based an analysis of data collected by these two projects.

  12. Hydrostatic bearings for a turbine fluid flow metering device

    DOE Patents [OSTI]

    Fincke, J.R.

    1980-05-02T23:59:59.000Z

    A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion.

  13. The practical equity implications of advanced metering infrastructure

    SciTech Connect (OSTI)

    Felder, Frank A.

    2010-07-15T23:59:59.000Z

    Reductions in advanced metering costs and the efficiency benefits of dynamic pricing make a compelling case to adopt both, particularly for industrial and commercial facilities. Regulators should seriously consider such policies for residential households as well. Regulators can take meaningful steps to mitigate, if not entirely offset, the possibility that some low-income ratepayers may have higher electricity bills with AM and DP. (author)

  14. Integration of Behind-the-Meter PV Fleet Forecasts into Utility...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Integration of Behind-the-Meter PV Fleet Forecasts into Utility Grid System Operations Integration of Behind-the-Meter PV Fleet Forecasts into Utility Grid System Operations Clean...

  15. Helping New Hampshire Achieve Its 25 x 25 Goal Renewable Energy Incentives, Energy Metering, and

    E-Print Network [OSTI]

    Lotko, William

    Helping New Hampshire Achieve Its 25 x 25 Goal Renewable Energy Incentives, Energy Metering................................................................................................................. 7 2. RENEWABLE ENERGY: FINANCING INCENTIVES......................................... 8 2.1 LOANS............................................................ 12 3. RENEWABLE ENERGY: PRODUCTION INCENTIVES................................... 14 3.1 NET METERING

  16. Design of high pressure metering and regulating stations

    SciTech Connect (OSTI)

    Rehler, D.A. [Oklahoma Natural Gas Co., Enid, OK (United States)

    1995-12-01T23:59:59.000Z

    Metering and regulating stations effectively serve as the cash registers of the natural gas industry. While the potential for lost revenue resulting from improper design is a serious consideration, it is not the only one. The potential exists for problems such as excessive noise levels, inaccurate reflection of lost and unaccounted-for gas, and numerous potentially hazardous situations. The best time to limit the potential for problems is during the design process. This, together with the critical nature of these stations, dictates that proper design is imperative. Proper design of metering and regulating stations is a constantly changing and extremely complicated subject. There are virtually an infinite number of situations that the designer can encounter in evaluating his design. In view of this, it is impossible to develop a cookbook method of designing these stations that covers all possible situations. The emphasis of this paper is to briefly touch on the major aspects of metering and regulating station design. Steps involved in station design are: 1. Collection of data on the proposed station. 2. Determination of piping configuration. 3. Selection of measurement equipment. 4. Selection of pressure regulating and overpressure protection equipment. 5. Communication of the final design to field personnel.

  17. Naval Undersea Warfare Center Division Newport utilities metering, Phase 1

    SciTech Connect (OSTI)

    Carroll, D.M.

    1992-11-01T23:59:59.000Z

    Pacific Northwest Laboratory developed this report for the US Navy's Naval Undersea Warfare Center Division Newport, Rhode Island (NUWC). The purpose of the report was to review options for metering electricity and steam used in the NUWC compound, and to make recommendations to NUWC for implementation under a follow-on project. An additional NUWC concern is a proposed rate change by the servicing utility, Newport Electric, which would make a significant shift from consumption to demand billing, and what effect that rate change would have on the NUWC utility budget. Automated, remote reading meters are available which would allow NUWC to monitor its actual utility consumption and demand for both the entire NUWC compound and by end-use in individual buildings. Technology is available to perform the meter reads and manipulate the data using a personal computer with minimal staff requirement. This is not meant to mislead the reader into assuming that there is no requirement for routine preventive maintenance. All equipment requires routine maintenance to maintain its accuracy. While PNL reviewed the data collected during the site visit, however, it became obvious that significant opportunities exist for reducing the utility costs other than accounting for actual consumption and demand. Unit costs for both steam and electricity are unnecessarily high, and options are presented in this report for reducing them. Additionally, NUWC has an opportunity to undertake a comprehensive energy resource management program to significantly reduce its energy demand, consumption, and costs.

  18. Naval Undersea Warfare Center Division Newport utilities metering, Phase 1

    SciTech Connect (OSTI)

    Carroll, D.M.

    1992-11-01T23:59:59.000Z

    Pacific Northwest Laboratory developed this report for the US Navy`s Naval Undersea Warfare Center Division Newport, Rhode Island (NUWC). The purpose of the report was to review options for metering electricity and steam used in the NUWC compound, and to make recommendations to NUWC for implementation under a follow-on project. An additional NUWC concern is a proposed rate change by the servicing utility, Newport Electric, which would make a significant shift from consumption to demand billing, and what effect that rate change would have on the NUWC utility budget. Automated, remote reading meters are available which would allow NUWC to monitor its actual utility consumption and demand for both the entire NUWC compound and by end-use in individual buildings. Technology is available to perform the meter reads and manipulate the data using a personal computer with minimal staff requirement. This is not meant to mislead the reader into assuming that there is no requirement for routine preventive maintenance. All equipment requires routine maintenance to maintain its accuracy. While PNL reviewed the data collected during the site visit, however, it became obvious that significant opportunities exist for reducing the utility costs other than accounting for actual consumption and demand. Unit costs for both steam and electricity are unnecessarily high, and options are presented in this report for reducing them. Additionally, NUWC has an opportunity to undertake a comprehensive energy resource management program to significantly reduce its energy demand, consumption, and costs.

  19. The effects between two slotted plate flow meter under single, two, three components flow condition

    E-Print Network [OSTI]

    Park, Sang Hyan

    2005-02-17T23:59:59.000Z

    suggested a universal calibration for the slotted flow meter under various situations using only the Euler number (Eu) and the ratio of ? = AAslot pipe The calibration curve of the slotted meter?s flow coefficient KY versus Euler number was obtained..., or Three Component Flow Conditions. (December 2004) Sang Hyun Park, B.S., Yonsei University, Republic of Korea Chair of Advisory Committee: Dr. Gerald L. Morrison In previous work on the slotted flow meter, repeatibility and reproducibility were studied...

  20. Status of Net Metering: Assessing the Potential to Reach Program Caps (Poster)

    SciTech Connect (OSTI)

    Heeter, J.; Bird, L.; Gelman, R.

    2014-10-01T23:59:59.000Z

    Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

  1. Status of Net Metering: Assessing the Potential to Reach Program Caps

    SciTech Connect (OSTI)

    Heeter, J.; Gelman, R.; Bird, L.

    2014-09-01T23:59:59.000Z

    Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

  2. Video game console usage and national energy consumption: Results from a field-metering study

    E-Print Network [OSTI]

    Desroches, Louis-Benoit

    2013-01-01T23:59:59.000Z

    with their free energy audit program. Meters were installedinstalled as part of an energy audit program. Users may be

  3. Behavioral/Systems/Cognitive Tagging the Neuronal Entrainment to Beat and Meter

    E-Print Network [OSTI]

    and meter perception (Large and Kolen, 1994; van Noorden and Moelants, 1999; Large, 2008) proposes that beat

  4. United States- Land Based and Offshore Annual Average Wind Speed at 100 Meters

    Broader source: Energy.gov [DOE]

    Full-size, high resolution version of the 100-meter land-based and offshore wind speed resource map.

  5. An investigation of effects of flow conditioning on straight tube Coriolis meter

    E-Print Network [OSTI]

    Shukla, Shashank

    2009-05-15T23:59:59.000Z

    metering can be very beneficial for the following1, 2. 1.1.1 Layout of production facilities Use of multiphase meters reduces the hardware needed for onshore, offshore topside and offshore subsea applications by eliminating the need of dedicated test... Coriolis meters are essentially aeroelastic devices; and as such involve coupled dynamic interaction of fluid dynamics and structural system. The Coriolis meter basically consists of a tube conveying fluid (lying in one plane and clamped at its ends...

  6. eMeter: An interactive energy monitor In this work, we propose an interactive load monitoring

    E-Print Network [OSTI]

    level. Therefore, we extended the capabilities of a smart elec- tricity meter and developed a mobile interfaces Merging smart meters and mobile devices Timely consumption feedback and guidance with re- spectComp 2009, Sep 30 ­ Oct 3, 2009, Orlando, FL, USA #12;household once smart meters are introduced. We wanted

  7. Evaluating Government's Policies on Promoting Smart Metering Diffusion in Retail Electricity Markets via

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    Evaluating Government's Policies on Promoting Smart Metering Diffusion in Retail Electricity on promoting smart metering in the U.K. retail electricity market. We break down the policy into four possible recommendations for the energy mar- ket is the adoption of smart metering technology, which, in addition

  8. Efficient and Secure Wireless Communications for Advanced Metering Infrastructure in Smart Grids

    E-Print Network [OSTI]

    Qiu, Robert Caiming

    1 Efficient and Secure Wireless Communications for Advanced Metering Infrastructure in Smart Grids metering infrastructure (AMI) [3] is a key task in smart grid [6] [4]. In such a system, each power user is equipped with a smart meter with the capability of two- way communications, which can monitor the power

  9. A Distortion-Theoretic Perspective for Redundant Metering Security in a Smart Grid

    E-Print Network [OSTI]

    Kundur, Deepa

    A Distortion-Theoretic Perspective for Redundant Metering Security in a Smart Grid Mustafa El--In a smart grid environment some customers employ third-party meters and terminals for integrity verification of the smart meter power measurements reported by the electric utility company. We address the security issues

  10. Missing Data Handling for Meter Data Management System Ru-Sen Jeng1

    E-Print Network [OSTI]

    Chen, Ling-Jyh

    Applications]: Types of Systems-- Decision support (e.g., MIS) Keywords Missing data, Smart meter, MDMS 1-scale deployments. As a consequence, conventional missing data handling methods are not applicable to smart meterMissing Data Handling for Meter Data Management System Ru-Sen Jeng1 , Chien-Yu Kuo1 , Yao-hua Ho1

  11. Neighborhood Watch: Security and Privacy Analysis of Automatic Meter Reading Systems

    E-Print Network [OSTI]

    Xu, Wenyuan

    gruteser@winlab.rutgers.edu ABSTRACT Research on smart meters has shown that fine-grained en- ergy usage data poses privacy risks since it allows inferences about activities inside the home. While smart meter-1-4503-1651-4/12/10 ...$15.00. 1. INTRODUCTION Much attention has been devoted to smart meters, as they play a central role

  12. Too expensive to meter: The influence of transaction costs in transportation and

    E-Print Network [OSTI]

    Odlyzko, Andrew M.

    . "Smart meters" that charge different prices, de- pending either on time of day, or, in even moreToo expensive to meter: The influence of transaction costs in transportation and communication in their homes electrical energy too cheap to meter, ... It is not too much to expect that our children will know

  13. Capacity Analysis of a Wireless Backhaul for Metering in the Smart Grid

    E-Print Network [OSTI]

    Namboodiri, Vinod

    Capacity Analysis of a Wireless Backhaul for Metering in the Smart Grid Babak Karimi and Vinod. With the introduction of AMI technology, two-way communication between a smart meter (SM) and the control center, as well as between the smart meter and customer loads would be facilitated for demand response, dynamic

  14. SMART METER PRIVACY USING A RECHARGEABLE BATTERY: MINIMIZING THE RATE OF INFORMATION LEAKAGE

    E-Print Network [OSTI]

    Khisti, Ashish

    SMART METER PRIVACY USING A RECHARGEABLE BATTERY: MINIMIZING THE RATE OF INFORMATION LEAKAGE David. INTRODUCTION Deployments of smart electricity meters to residential homes con- tinue unabated around the world resources. Smart meters are essential to coordinate the desired charging and discharg- ing of the batteries

  15. Designing Privacy-preserving Smart Meters with Low-cost Microcontrollers

    E-Print Network [OSTI]

    Shenoy, Prashant

    Designing Privacy-preserving Smart Meters with Low-cost Microcontrollers Andres Molina Microsoft Research Cambridge Abstract. Smart meters that track fine-grained electricity usage and implement smart meter deployment is that fine-grained usage data indirectly reveals detailed information about

  16. Tracking States of Massive Electrical Appliances by Lightweight Metering and Sequence Decoding

    E-Print Network [OSTI]

    Wang, Yongcai

    to track the on/off states of N appliances by deploying only m smart meters on the power load tree, where m demonstrate some interesting structures of the problem. Keywords Energy auditing, Smart meter, Deployment smart meter networks, and thus suffer from the high deploy- ment, maintenance and data collection costs

  17. Too expensive to meter: The influence of transaction costs in transportation and

    E-Print Network [OSTI]

    Odlyzko, Andrew M.

    in the electricity sector. Just the opposite appears to be happening. ``Smart meters'' that charge di#erent pricesToo expensive to meter: The influence of transaction costs in transportation and communication to meter, ... It is not too much to expect that our children will know of great periodic regional famines

  18. Infants Prefer the Musical Meter of Their Own Culture: A Cross-Cultural Comparison

    E-Print Network [OSTI]

    Ahmad, Sajjad

    , American infants preferred Western over Balkan meter, whereas Turkish infants, who were familiar with both Western and Balkan meters, exhibited no preference. Experiments 2 and 3 presented infants with either a Western or Balkan meter paired with an arbitrary rhythm with complex ratios not common to any musical

  19. Metering Plan: Monitoring Energy and Potable Water Use in PNNL EMS4 Buildings

    SciTech Connect (OSTI)

    Pope, Jason E.

    2012-07-25T23:59:59.000Z

    This Plan presents progress toward the metering goals shared by all national laboratories and discusses PNNL's contemporary approach to the installation of new meters. In addition, the Plan discusses the data analysis techniques with which PNNL is working to mature using endless data streams made available as a result of increased meter deployment.

  20. Compressed Meter Reading for Delay-sensitive and Secure Load Report in Smart Grid

    E-Print Network [OSTI]

    Qiu, Robert Caiming

    of smart meters, which collects the current load of smart meters installed at each home and then forwards1 Compressed Meter Reading for Delay-sensitive and Secure Load Report in Smart Grid Husheng Li, Rukun Mao, Lifeng Lai and Robert. C. Qiu Abstract-- It is a key task in smart grid to send the readings

  1. Testing the 2-element 4-wire delta watthour meter

    E-Print Network [OSTI]

    Grasshoff, Lynn Howard

    1950-01-01T23:59:59.000Z

    by interaction of the fluxes and disk eddy currents of the various elements. Since the 2. Ihrtin, Z. S. , Some Features of Present Day Polyphass 1+ters, p. 7 elements had to be plaoed at vaz ious locations around the periphery of the disk, spaoe displacement... of the meter which is inversely pro- portional to the load, Potential-current or current?potentis1 interference is the reaction caused by interaction of the flux of any potential or current electromagnet and the disk eddy currents induced respectively...

  2. Testing the 2-element 4-wire delta watthour meter 

    E-Print Network [OSTI]

    Grasshoff, Lynn Howard

    1950-01-01T23:59:59.000Z

    & and other material& and for affording valuable suggestions for the prepaxation of this thesis. Appreciation is also exnxressed to M! . R. H. Mighell and Mr. H. E. Trekell of the General Electric Company fax supplying a ~ire delta meter and various... four wire delta system is used to supply polyphase and single phase loads from a bank of delta-oonneeted transformers. The squit is illustrated in Pigure L, Polyphase loads are supplied in the usual manner from the three lines a b-o, and single phase...

  3. ESB Smart Meter Projects (Smart Grid Project) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A Potential MicrohydroDistrict ofDongjinDynetek42EOPEPODESB Smart Meter

  4. Smart Meters and a Smarter Grid | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartment of Energy Ready,Smart Grid RFIGrid: Enabler ofSmart Meters

  5. BPA Metering Services Editing and Estimating Procedures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office511041cloth DocumentationProductsAlternativeOperationalAugustDecade Later: AreAugust 19, 2009 InMetering

  6. Smart Meter Investments Support Rural Economy in Arkansas

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn April 23, 2014,Zaleski - PolicyWork Force withNonprofit---5---12DOESmarttheSmart Meter

  7. California Solar Initiative (CSI) Thermal Program Metering Installation Guide Purpose: The purpose of this metering installation guide is to provide participating eligible contractors

    E-Print Network [OSTI]

    1 California Solar Initiative (CSI) Thermal Program Metering Installation Guide Purpose and monitoring purposes: Customer Performance Monitoring (CPM), Opt-in Measurement and Evaluation (M&E) and 70 with interpreting the following schematics. 1. Customer Performance Monitoring (CPM) For CPM, metering either

  8. Meter scale plasma source for plasma wakefield experiments

    SciTech Connect (OSTI)

    Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J. [Department of Electrical Engineering, University of California Los Angeles, Los Angeles, CA 90095 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2012-12-21T23:59:59.000Z

    High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 10{sup 17} cm{sup -3} has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

  9. The magnetic flywheel flow meter: Theoretical and experimental contributions

    SciTech Connect (OSTI)

    Buchenau, D., E-mail: d.buchenau@hzdr.de; Galindo, V.; Eckert, S. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstraße 400, 01328 Dresden (Germany)

    2014-06-02T23:59:59.000Z

    The development of contactless flow meters is an important issue for monitoring and controlling of processes in different application fields, like metallurgy, liquid metal casting, or cooling systems for nuclear reactors and transmutation machines. Shercliff described in his book “The Theory of Electromagnetic Flow Measurement, Cambridge University Press, 1962” a simple and robust device for contact-less measurements of liquid metal flow rates which is known as magnetic flywheel. The sensor consists of several permanent magnets attached on a rotatable soft iron plate. This arrangement will be placed closely to the liquid metal flow to be measured, so that the field of the permanent magnets penetrates into the fluid volume. The flywheel will be accelerated by a Lorentz force arising from the interaction between the magnetic field and the moving liquid. Steady rotation rates of the flywheel can be taken as a measure for the mean flow rate inside the fluid channel. The present paper provides a detailed theoretical description of the sensor in order to gain a better insight into the functional principle of the magnetic flywheel. Theoretical predictions are confirmed by corresponding laboratory experiments. For that purpose, a laboratory model of such a flow meter was built and tested on a GaInSn-loop under various test conditions.

  10. Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment Deeper

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to:Ezfeedflag JumpID-fTri Global Energy LLCEnergy) Redirect pageonBeowawe Geothermal Field |

  11. Two-Meter Temperature Surveys for Geothermal Exploration Project at NAS

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTown of Ladoga, IndianaTurtle Airships Jump to:TwiggsJemez

  12. 2008 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Smart Meters, Rates and the Customer

    E-Print Network [OSTI]

    © 2008 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Smart Meters, OR #12;2 SDG&E Smart Meter Goals · Install AMI/smart metering for all SDG&E electric and gas business're starting to recreate our relationship with customers and transform our company #12;Smart Meter Business

  13. Photoelastic stress analysis on a Phoenix 7. 9-meter blade

    SciTech Connect (OSTI)

    Musial, W.D.; Jenks, M.D.; Osgood, R.M.; Johnson, J.A.

    1991-10-01T23:59:59.000Z

    Photoelastic tests were conducted on the Phoenix 7.9-meter blade to develop the basic methodology for locating critical strain areas on full-scale composite structures. Under relatively low elastic loading the strain fields over various regions on the blade planform were documented with 35mm photographs under different loading conditions at the Solar Energy Research Institute (SERI) Structural Test Facility (STF). Strain concentrations were easily located and quantified. Principal strain magnitudes and directions were determined at the highest strain areas using separator gages. Results were compared to measured operating loads. This experiment demonstrated the value of experimental stress analysis using the photoelastic technique for the evaluation of composite blade designs. 9 refs., 6 figs., 3 tabs.

  14. Plutonium detection with a new fission neutron survey meter

    SciTech Connect (OSTI)

    Klett, A. [EG and G Berthold, Bad Wildbad (Germany)] [EG and G Berthold, Bad Wildbad (Germany)

    1999-08-01T23:59:59.000Z

    The search for illicit trafficking or hidden plutonium sources has become a pressing issue, especially since the breakdown of the former Soviet Union. Plutonium is extremely dangerous and hard to detect over large distances. The {alpha}-particles and X-rays which are emitted by plutonium isotopes can easily be shielded by the material itself or by surroundings. Besides a few {gamma}`s, the only penetrating radiation emitted by plutonium samples are neutrons from spontaneous fission. Therefore a special neutron survey meter with unrivaled sensitivity for fission neutrons has been newly designed. The hand-held, commercially available instrument has an approximate weight of 4 kg and is battery driven. The neutron probe consists of a {sup 3}He proportional counter tube, a moderator and integrated electronics. The sensitivity is sufficient to detect plutonium masses below 100 g at a distance of 1 m within a few seconds.

  15. Prison Industries Metering at the Texas Department of Criminal Justice: Two Years of Operational Experience

    E-Print Network [OSTI]

    Bryant, J.; McBride, J.; Merka, T.

    2003-01-01T23:59:59.000Z

    PRISON INDUSTRIES METERING AT THE TEXAS DEPARTMENT OF CRIMINAL JUSTICE: TWO YEARS OF OPERATIONAL EXPERIENCE John A. Bryant John R. McBride Tom Merka Assistant Professor Chief Executive Officer Director of Utilities & Energy Texas A... in the use of energy metering to promote cost-effective prison operation. REFERENCES 1. John A. Bryant, John McBride, Tom Merka, ?State-of-the-Art Energy Sub-metering Texas Department of Criminal Justice Industries,? Proceedings of the 1st...

  16. An analysis of an application of radioactive ionization for gas flow metering

    E-Print Network [OSTI]

    Lam, Carroll Frank

    1959-01-01T23:59:59.000Z

    OF FIGURES CHAP TER I. INTRODUCTION II. EXPERIMENTAL PROCEDURE III. MEASUREMENT OF MARK I CHARACTERISTICS IV. MEASUREMENT OF MARK II CHARACTERISTICS -3 V. CONCLUSIONS . 17 35 BIBLIOGRAPHY . 37 LIST OF FIGURES FIGURE PAGE 1. A Diagram of Rutherford...'s Apparatus Z. An Ezperimental Flow Meter . 3. Mark I Meter and Test Equipment 4. Electrical Circuit 5. Current vs. Flow Rate Curve for Mark I Meter. . . . . . . . . . . . . 6. Current vs. Flow Rate for DifferentSource Spacings. . . . . . . . . . 7...

  17. automatic gas meter-reading: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Last Page Topic Index 1 Neighborhood Watch: Security and Privacy Analysis of Automatic Meter Reading Systems Engineering Websites Summary: in transforming the current electrical...

  18. Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve

    SciTech Connect (OSTI)

    Song, Li; Wang, Gang; Brambley, Michael R.

    2013-04-28T23:59:59.000Z

    A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

  19. Now that we have smart meters, what do we do with them?

    SciTech Connect (OSTI)

    NONE

    2010-01-15T23:59:59.000Z

    For years, electric utilities have been dreaming about the day when they would have smart meters on customers' premises. However, there have always been lingering doubts among some consumer advocates and critics of the smart metering schemes about their cost-effectiveness. An issue that is beginning to become noticed is that installing smart meters and introducing variable pricing will accomplish very little unless the price signals are communicated to consumers and -- more important -- to energy-using devices beyond the meter. Since consumers are unlikely to sit around watching variable prices and adjusting consumption or thermostat settings, ways must be found for the price signals to automatically and directly communicate with devices,.

  20. Microsoft Word - Ross-Lexington No1 Meter project-CX .doc

    Broader source: Energy.gov (indexed) [DOE]

    Power Administration (BPA) proposes to install meters under the Ross-Lexington No. 1 transmission line, between towers 15 and 16, to better understand and predict line sag....

  1. Trinity College Green Week 2012 Energy Competition Win a Domestic Energy Meter

    E-Print Network [OSTI]

    O'Mahony, Donal E.

    Trinity College Green Week 2012 Energy Competition ­ Win a Domestic Energy Meter As part of College Green Week the "e3" programme and Director of Buildings Office is promoting an energy related would you like to win a domestic whole house energy meter as part of Trinity College Green Week 2012

  2. A Scalable Soft Spot Analysis Methodology for Compound Noise Effects in Nano-meter Circuits

    E-Print Network [OSTI]

    California at San Diego, University of

    A Scalable Soft Spot Analysis Methodology for Compound Noise Effects in Nano-meter Circuits Chong methodology to study the vulnerability of digital ICs exposed to nano-meter noise and transient soft errors. First, we define "softness" as an important characteristic to gauge system vulnerability. Then several

  3. Energy-Harvesting Thermoelectric Sensing for Unobtrusive Water and Appliance Metering

    E-Print Network [OSTI]

    Dutta, Prabal

    Energy-Harvesting Thermoelectric Sensing for Unobtrusive Water and Appliance Metering Bradford that meters using the same thermoelectric generator with which it powers itself. In short, the rate at which be harvested with a thermoelectric generator (TEG) to power a sensor node. TEGs utilize the Seebeck effect

  4. Unaccounted-for gas project. Measurement Task Force (orifice meter studies). Volume 2B. Final report

    SciTech Connect (OSTI)

    Godkin, B.J.; Robertson, J.D.; Wlasenko, R.G.; Cowgill, R.M.; Grinstead, J.R.

    1990-06-01T23:59:59.000Z

    The study was aimed at determining unaccounted-for (UAF) gas volumes resulting from operating Pacific Gas and Electric Co.'s transmission and distribution systems during 1987. Activities and methods are described and results are presented for research conducted on orifice meter accuracy. The Measurement Task Force determined that orifice metering inaccuracies were the largest single contributor to 1987 UAF.

  5. A Technology for Electronic Energy Meters Intelligent Accounting Using Distributed Database over TCP/IP Network

    E-Print Network [OSTI]

    Borissova, Daniela

    4 8 A Technology for Electronic Energy Meters Intelligent Accounting Using Distributed Database in their entirety. 2. Electronic energy metersaccountingtechnology developed inthe project The technology under Collection Electronic Energy Meters Distributed Database over TCP/IP Network Optical Head Optical Port RS-232

  6. MODEL-DRIVEN ANALYTICS OF ENERGY METER DATA IN SMART HOMES

    E-Print Network [OSTI]

    Shenoy, Prashant

    MODEL-DRIVEN ANALYTICS OF ENERGY METER DATA IN SMART HOMES A Dissertation Presented by SEAN BARKER administrative tasks, to Tyler Trafford for frequent technical support, and to my past and present labmates Barker 2014 All Rights Reserved #12;MODEL-DRIVEN ANALYTICS OF ENERGY METER DATA IN SMART HOMES

  7. On Required Distances to Absorb Metering Delays C. Gwiggner, S. Nagaoka

    E-Print Network [OSTI]

    Gwiggner, Claus Peter

    On Required Distances to Absorb Metering Delays C. Gwiggner, S. Nagaoka Electronic Navigation Research Institute Chofu, Tokyo Abstract We analyze the distance that is required to absorb metering delays are a common phenomenon [1]. The reason is that uncertainty factors, including competition for punctual

  8. Energy Metering for Free: Augmenting Switching Regulators for Real-Time Monitoring

    E-Print Network [OSTI]

    Energy Metering for Free: Augmenting Switching Regulators for Real-Time Monitoring Prabal Dutta of Technology Berkeley, CA 94720 Cambridge, MA 02139 Abstract We present iCount, a new energy meter design. For many systems that have a built-in switching regulator, adding a single wire between the regulator

  9. Power Line Carrier (PLC) Signal Analysis of Smart Meters for Outlier Detection

    E-Print Network [OSTI]

    Akella, Srinivas

    Power Line Carrier (PLC) Signal Analysis of Smart Meters for Outlier Detection Rakesh Rao Dept-- A method for identifying outliers among a set of smart meters by using the power line carrier (PLC) signal strength is presented in this paper. The broad goal is to use the PLC signal as a predictor of transmission

  10. Towards a Secure, Wireless-Based, Home Area Network for Metering in Smart Grids

    E-Print Network [OSTI]

    Namboodiri, Vinod

    1 Towards a Secure, Wireless-Based, Home Area Network for Metering in Smart Grids Vinod Namboodiri and the consumer. This work takes a comprehensive look at wireless security in the smart meter-based home, Student Member, IEEE, Ward Jewell, Fellow, IEEE Abstract--Compared to the conventional grid, the smart

  11. Electricit de France's study of the acoustic scintillation flow meter results in expanding its range and sensitivity

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    for the next generation of acoustic scintillation flow meters. 1. Background For EDF's hydraulic power division, turbine flow metering represents a high stake issue as it involves a significant amount of knowhow, work

  12. DREAM: DiffeRentially privatE smArt Metering

    E-Print Network [OSTI]

    Acs, Gergely

    2012-01-01T23:59:59.000Z

    This paper presents a new privacy-preserving smart metering system. Our scheme is private under the differential privacy model and therefore provides strong and provable guarantees. With our scheme, an (electricity) supplier can periodically collect data from smart meters and derive aggregated statistics while learning only limited information about the activities of individual households. For example, a supplier cannot tell from a user's trace when he watched TV or turned on heating. Our scheme is simple, efficient and practical. Processing cost is very limited: smart meters only have to add noise to their data and encrypt the results with an efficient stream cipher.

  13. Instrument Qualification of Custom Fabricated Water Activity Meter for Hot Cell Use

    SciTech Connect (OSTI)

    McCoskey, Jacob K.

    2014-01-22T23:59:59.000Z

    This report describes a custom fabricated water activity meter and the results of the qualification of this meter as described in the laboratory test plan LAB-PLN-11-00012, Testing and Validation of an Enhanced Acquisition and Control System. It was calibrated against several NaOH solutions of varying concentrations to quantify the accuracy and precision of the instrument at 20 °C and 60 °C. Also, a schematic and parts list of the equipment used to make the water activity meter will be presented in this report.

  14. Sub-metering to Electricity Use in Large-scale Commercial Buildings

    E-Print Network [OSTI]

    Yuan, W.

    2006-01-01T23:59:59.000Z

    ~240Hotel251218113~129Office Building181118103~119government office building4582775~89 #0;?#0;? Great Difference between each type Sub-metering and statistics to electricity use in commercial buildings 5 Situation of Energy consumption in Large...Sub-metering to Electricity Use in Large-scale Commercial Buildings Wang YuanTsinghua University2006.11 Sub-metering and statistics to electricity use in commercial buildings 2 Index #0;?#0;? Situation of Energy consumption in commercial buildings...

  15. Smart Meter Aggregation via Secret-Sharing George Danezis, Cdric Fournet, Markulf Kohlweiss, Santiago Zanella-Bguelin

    E-Print Network [OSTI]

    Danezis, George

    Smart Meter Aggregation via Secret-Sharing George Danezis, Cédric Fournet, Markulf Kohlweiss,fournet,markulf,santiago}@microsoft.com ABSTRACT We design and prototype protocols for processing smart- meter readings while preserving user-sharing; smart me- tering; privacy 1. INTRODUCTION Smart metering deployments have been plagued with pri- vacy

  16. Private Memoirs of a Smart Meter Andres Molina-Markham, Prashant Shenoy, Kevin Fu, Emmanuel Cecchet, and David Irwin

    E-Print Network [OSTI]

    Shenoy, Prashant

    Private Memoirs of a Smart Meter Andr´es Molina-Markham, Prashant Shenoy, Kevin Fu, Emmanuel,shenoy,kevinfu,cecchet,irwin}@cs.umass.edu Abstract Household smart meters that measure power consumption in real-time at fine granularities are the foundation of a future smart electricity grid. However, the widespread deployment of smart meters has serious

  17. Have You Used an Electric Meter to Measure Your Energy Use? ...

    Broader source: Energy.gov (indexed) [DOE]

    of fun to put actual numbers to the various items in your home. Have you used an electric meter to measure your energy use? Tell us about your experience. Each Thursday, you have...

  18. Proposed Metering and Instrumentation Monitoring and Analysis Plan and Budget: Alamo Community College District 

    E-Print Network [OSTI]

    O'Neal, D. L.; Carlson, K. A.; Sweeney, J., Jr.; Milligan, K.

    2002-01-01T23:59:59.000Z

    The purpose of this overview is to outline the metering points that will be monitored by the Energy Systems Laboratory (ESL). At three of the campuses, Alamo Community College District (ACCD) has a central energy management system (EMS) installed...

  19. High Resolution Study of Micro-Meter Particle Detachment and Resuspension on Different Surfaces

    E-Print Network [OSTI]

    Kassab, Asmaa 1983-

    2012-08-16T23:59:59.000Z

    In an effort to understand the resuspension phenomena, interactions of spherical micro-meter particles (glass beads (GB) and Stainless steel (SS)) were investigated experimentally on different surfaces (glass, ceramic, hardwood, metal and chemical...

  20. 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. HIGH-ACCURACY LASER POWER AND ENERGY METER CALIBRATION SYSTEM . . . . . . . . 2

    E-Print Network [OSTI]

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. HIGH-ACCURACY LASER POWER AND ENERGY METER CALIBRATION SYSTEM . . . . . . . . 2 2.1 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3.1 High-Accuracy Calibration System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3.2.1 Basic cryogenic radiometer operating principal

  1. The Economic Value of PV and Net Metering to Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01T23:59:59.000Z

    a Substantial Benefit of Solar PV”, The Electricity Journal,2008. MRW & Associates. “Solar PV and Retail Rate Design”,The Economic Value of PV and Net Metering to Residential

  2. Cryotank Work Work on the 5.5 meter composite cryotank is well under

    E-Print Network [OSTI]

    at The Boeing Company in Seattle, WA. The 5.5 meter tank will be the largest automated fiber placement, out Highlights May 2013 The 5.5 m tank undergoes Automated Fiber Placement at Boeing. These flute segments

  3. Proposed Metering and Instrumentation Monitoring and Analysis Plan and Budget: Alamo Community College District

    E-Print Network [OSTI]

    O'Neal, D. L.; Carlson, K. A.; Sweeney, J., Jr.; Milligan, K.

    2002-01-01T23:59:59.000Z

    The purpose of this overview is to outline the metering points that will be monitored by the Energy Systems Laboratory (ESL). At three of the campuses, Alamo Community College District (ACCD) has a central energy management system (EMS) installed...

  4. Smart-Metering for Monitoring Building Power Distribution Network using Instantaneous Phasor Computations of Electrical Signals

    E-Print Network [OSTI]

    K.R., Krishnanand

    2013-01-01T23:59:59.000Z

    Man, H. and L. Jae-Hyun, Smart home energy management systemand implementation of smart home energy management systemsSocial network of smart-metered homes and SMEs for grid-

  5. Why Insertion Turbine Meters are Replacing Orifice Plates for Steam Flow Measurement

    E-Print Network [OSTI]

    Rusnak, J. J.

    1983-01-01T23:59:59.000Z

    WHY INSERTION TURBINE MBTBRS A E REPLACING ORIFICE PLATES FOR STEAM FLOW MEASURE ENT J. J. Rusnak Engineering Measurements Company Longmont, Colorado ABSTRACT Flow measurement is a complex and application related discipline. It borders... to be instrumented quickly, economically and without dis rupting production; and further, these meters had to be accurate in order to be useful in making energy saving decisions. Thus, the entry of the insertion turbine meter for steam in 1975. Since then it has...

  6. Flow Metering and Oxygen Trim Control Reduce Dairy Steam Plant Fuel Costs

    E-Print Network [OSTI]

    Foster, E. L.; Nelson, R. L.

    FLOW METERING AND OXYGEN TRIM CONTROL REDUCE DAIRY STEAM PLANT FUEL COSTS Edward L. Foster, Plant Engineer, Dairy Farm Products, Orrville Ohio Robert L. Nelson, Manager Engineering, Westinghouse Combustion Control DiVision, Orrville, Ohio... boiler loads. A Westinghouse Hagan Ring' Balance integrating flow meter was selected for natural gas flow measurement and Westinghouse Veritrak differential pressure transmitters with remote round chart recorders were selected for steam flow...

  7. Design of an electronic phase angle meter for use with electronic analog computers

    E-Print Network [OSTI]

    Cunningham, Allen Baxter

    1957-01-01T23:59:59.000Z

    DESIGN OF AN ELECTRONIC PHASE ANGLE METER FOR USE WITH ELECTRONIC ANALOG COMPUTERS A Thesis By Allen Baxter Cunningham Submitted to the Graduate School of the Agricultural and Mechanical College of Texas in partial fulfillment... of the requirements for the degree of MASTFR OF SCIFNCE August 1957 Ma]or Sub]ect! Electrical Engineering DESIGN OF AN ELECTRONIC PHASE ANGLE METER FOR USE WITH ELECTRONIC ANALOG COMPUTERS A Thesis Allen Baxter Cunningham Approved e to style and conte...

  8. Evaluating Government's Policies on Promoting Smart Metering in Retail Electricity Markets via Agent Based Simulation

    E-Print Network [OSTI]

    Zhang, Tao; Nuttall, William J

    to the potential energy savings, final customers for electricity, natural gas…are provided with competitively priced individual meters that accurately reflect the final customer’s actual energy consumption and that provide information on actual time of use” [13... in the UK energy market. Lessons from international experience (e.g. Italy, Sweden and California) suggest that introducing smart metering in the context of monopoly provision can be a very successful strategy. However, the characteristics of competition...

  9. Capacitance-based prover for gas flow meters

    E-Print Network [OSTI]

    Pipkins, Sean Patrick

    1995-01-01T23:59:59.000Z

    ;?= enthalpy of the air at the inlet. H Uo =U +RT Uo =Cv(T To)+RT, (36) 24 Equation (35) can be written as c (T-T)=[c (T?? T)+RT. , ?] Il ? ' n j (37) Solving Equation (37) for T gives the equation used to calculate the temperature profiles of the air.... . . . . Relation of Capacitance Change to Molar Flow Rate. DiIferential Method Integral Method THEORETICAL CALCULATIONS. Calculated C. Experimental C. Thermal Expansion Effects . . Capacitance Change Due to Length Change Capacitance Change Due to Radius...

  10. Temperature, Temperature, Earth, geotherm for

    E-Print Network [OSTI]

    Treiman, Allan H.

    Temperature, Temperature, Earth, geotherm for total global heat flow Venus, geotherm for total global heat flow, 500 Ma #12;Temperature, Temperature, #12;Earth's modern regional continental geotherms Venusian Geotherms, 500 Ma Temperature, Temperature, After Blatt, Tracy, and Owens Petrology #12;Ca2Mg5Si8

  11. Using Wireless Power Meters to Measure Energy Use of Miscellaneous and Electronic Devices in Buildings

    SciTech Connect (OSTI)

    UC Berkeley, Berkeley, CA USA; Brown, Richard; Lanzisera, Steven; Cheung, Hoi Ying (Iris); Lai, Judy; Jiang, Xiaofan; Dawson-Haggerty, Stephen; Taneja, Jay; Ortiz, Jorge; Culler, David

    2011-05-24T23:59:59.000Z

    Miscellaneous and electronic devices consume about one-third of the primary energy used in U.S. buildings, and their energy use is increasing faster than other end-uses. Despite the success of policies, such as Energy Star, that promote more efficient miscellaneous and electronic products, much remains to be done to address the energy use of these devices if we are to achieve our energy and carbon reduction goals. Developing efficiency strategies for these products depends on better data about their actual usage, but very few studies have collected field data on the long-term energy used by a large sample of devices due to the difficulty and expense of collecting device-level energy data. This paper describes the development of an improved method for collecting device-level energy and power data using small, relatively inexpensive wireless power meters. These meters form a mesh network based on Internet standard protocols and can form networks of hundreds of metering points in a single building. Because the meters are relatively inexpensive and do not require manual data downloading, they can be left in the field for months or years to collect long time-series energy use data. In addition to the metering technology, we also describe a field protocol used to collect comprehensive, robust data on the miscellaneous and electronic devices in a building. The paper presents sample results from several case study buildings, in which all the plug-in devices for several homes were metered, and a representative sample of several hundred plug-in devices in a commercial office building were metered for several months.

  12. Development of Baseline Monthly Utility Models, Stabilization of Data Logging Environment and Development of Metering Plan and Shopping List for Fort Hood, Texas

    E-Print Network [OSTI]

    Saman, N. F.; Reddy, T. A.; Haberl, J. S.; Claridge, D. E.; Turner, W. D.

    1995-01-01T23:59:59.000Z

    sensors) at *ue west substation, and the installation of the ESL's Monitor software for use by the Energy Office at the base. The objective of Task C is to provide a metering plan and shopping list of necessary data points to provide CERL with energy... and EModel, and it was found that EModel gave more accurate modeling results than PRISM, and therefore EModel was used in the analysis. For Task B, a weather station that includes temperature, humidity and solar sensors was installed at the west substation...

  13. Optical position meters analyzed in the non-inertial reference frames

    E-Print Network [OSTI]

    Sergey P. Tarabrin; Alexander A. Seleznyov

    2008-09-03T23:59:59.000Z

    In the framework of General Relativity we develop a method for analysis of the operation of the optical position meters in their photodetectors proper reference frames. These frames are non-inertial in general due to the action of external fluctuative forces on meters test masses, including detectors. For comparison we also perform the calculations in the laboratory (globally inertial) reference frame and demonstrate that for certain optical schemes laboratory-based analysis results in unmeasurable quantities, in contrast to the detector-based analysis. We also calculate the response of the simplest optical meters to weak plane gravitational waves and fluctuative motions of their test masses. It is demonstrated that for the round-trip meter analysis in both the transverse-traceless (TT) and local Lorentz (LL) gauges produces equal results, while for the forward-trip meter corresponding results differ in accordance with different physical assumptions (e.g. procedure of clocks synchronization) implicitly underlying the construction of the TT and LL gauges.

  14. Response of a slotted plate flow meter to horizontal two phase flow

    E-Print Network [OSTI]

    Muralidharan, Vasanth

    2005-02-17T23:59:59.000Z

    there is a change in the pipeline geometry or 8 inclination. Severe riser slugging is an example of this effect and it can prevail for kilometers mainly in sea lines. When there are no transient effects or geometry/terrain effects the flow is steady... constant, a static differential pressure due to flow of the pure liquid is attained. 9 Therefore the static differential pressure lines of constant liquid flow rate become horizontal when the gas flow rate is reduced. 4. When the gas flow is increased...

  15. Powder River 0 20 40 KILOMETERS

    E-Print Network [OSTI]

    .S. coal basins. The Powder River Basin (PRB) in northeastern Wyoming and southeastern Montana (fig. 1 tons (MST), some 42 percent of the total coal pro- duction in the United States, making the PRB the single most important coal-producing basin in the Nation. About 426 MST (92 percent of total PRB coal

  16. OTRA-THS MAC to reduce Power Outage Data Collection Latency in a smart meter network

    SciTech Connect (OSTI)

    Garlapati, Shravan K [ORNL] [ORNL; Kuruganti, Phani Teja [ORNL] [ORNL; Buehrer, Richard M [ORNL] [ORNL; Reed, Jeffrey H [ORNL] [ORNL

    2014-01-01T23:59:59.000Z

    The deployment of advanced metering infrastructure by the electric utilities poses unique communication challenges, particularly as the number of meters per aggregator increases. During a power outage, a smart meter tries to report it instantaneously to the electric utility. In a densely populated residential/industrial locality, it is possible that a large number of smart meters simultaneously try to get access to the communication network to report the power outage. If the number of smart meters is very high of the order of tens of thousands (metropolitan areas), the power outage data flooding can lead to Random Access CHannel (RACH) congestion. Several utilities are considering the use of cellular network for smart meter communications. In 3G/4G cellular networks, RACH congestion not only leads to collisions, retransmissions and increased RACH delays, but also has the potential to disrupt the dedicated traffic flow by increasing the interference levels (3G CDMA). In order to overcome this problem, in this paper we propose a Time Hierarchical Scheme (THS) that reduces the intensity of power outage data flooding and power outage reporting delay by 6/7th, and 17/18th when compared to their respective values without THS. Also, we propose an Optimum Transmission Rate Adaptive (OTRA) MAC to optimize the latency in power outage data collection. The analysis and simulation results presented in this paper show that both the OTRA and THS features of the proposed MAC results in a Power Outage Data Collection Latency (PODCL) that is 1/10th of the 4G LTE PODCL.

  17. Constancy of built-in luminance meter measurements in diagnostic displays

    SciTech Connect (OSTI)

    Silosky, M., E-mail: michael.silosky@ucdenver.edu; Marsh, R. M. [Department of Radiology, University of Colorado, School of Medicine Aurora, Colorado 80045 (United States)] [Department of Radiology, University of Colorado, School of Medicine Aurora, Colorado 80045 (United States)

    2013-12-15T23:59:59.000Z

    Purpose: Liquid crystal displays used to interpret medical images are often equipped with built-in luminance meters to evaluate luminance response and Grayscale Standard Display Function conformance. This work evaluates agreement between luminance reported by the built-in meters and external measurements. Methods: The white level luminance was measured using a built-in meter and an external meter for 93 primary review workstations (Models MFGD 3420 and MDCG 3120-CB) with between 117 and 49?336 backlight hours (BLH). Measured luminance values were compared viat-test for displays with less than 25?000 BLH and those with more than 25?000 BLH. Bias between meters was also evaluated. Changes in luminance uniformity with increasing backlight hours were explored by determining the maximum luminance deviation (MLD) for subsets of these displays with less than 800 BLH and greater than 35?000 BLH. Results: The mean difference between built-in and external luminance measurements was 5.84% and 38.92% for displays with less than 25?000 and greater than 25?000 BLH, respectively, with a statistically significant difference in the means (p < 0.001). For displays with low BLH, a statistically significant bias was observed (p < 0.001) between built-in and external measurements. A high degree of correlation was observed between measurements made with two separate external meters (r = 0.999). The mean MLD was 9.5% and 11.2% for MDCG 3120-CB displays with less than 800 and greater than 35?000 BLH, respectively. The difference in the mean values was not statistically significant (p < 0.001). Conclusions: Disagreement between the white level luminance measured using the built-in and external meter increased with BLH. Consequently, reliance on values reported by the built-in luminance meter may result in a reduction in image contrast with time. Recommendations have been proposed regarding luminance response testing and corrective action for failing displays.

  18. Advanced Metering Plan for Monitoring Energy and Potable Water Use in PNNL EMS4 Buildings

    SciTech Connect (OSTI)

    Pope, Jason E.; Olson, Norman J.; Berman, Marc J.; Schielke, Dale R.

    2011-08-17T23:59:59.000Z

    This updated Advanced Metering Plan for monitoring whole building energy use in Pacific Northwest National Laboratory (PNNL) EMS4 buildings on the PNNL campus has been prepared in accordance with the requirements of the Energy Policy Act of 2005 (EPAct 2005), Section 103, U.S. Department of Energy (DOE) Order 430.2B, and Metering Best Practices, A Guide to Achieving Utility Resource Efficiency, Federal Energy Management Program, October 2007 (Sullivan et al. 2007). The initial PNNL plan was developed in July 2007 (Olson 2007), updated in September 2008 (Olson et al. 2008), updated in September 2009 (Olson et al. 2009), and updated again in August 2010 (Olson et al. 2010).

  19. Monitoring the Thermal Power of Nuclear Reactors with a Prototype Cubic Meter Antineutrino Detector

    E-Print Network [OSTI]

    A. Bernstein; N. S. Bowden; A. Misner; T. Palmer

    2008-04-30T23:59:59.000Z

    In this paper, we estimate how quickly and how precisely a reactor's operational status and thermal power can be monitored over hour to month time scales, using the antineutrino rate as measured by a cubic meter scale detector. Our results are obtained from a detector we have deployed and operated at 25 meter standoff from a reactor core. This prototype can detect a prompt reactor shutdown within five hours, and monitor relative thermal power to three percent within seven days. Monitoring of short-term power changes in this way may be useful in the context of International Atomic Energy Agency's (IAEA) Reactor Safeguards Regime, or other cooperative monitoring regimes.

  20. What can we learn from high-frequency appliance-level energy metering? Results from a field experiment

    E-Print Network [OSTI]

    Chen, VL; Delmas, MA; Kaiser, WJ; Locke, SL

    2015-01-01T23:59:59.000Z

    Newborough, M. , 2003. Dynamic energy-consumption indicatorsbehaviour and design. Energy Build. 35 (8), Please cite thisfrequency appliance-level energy metering? Results from a ?

  1. Evaluation of a slotted orifice plate flow meter using horizontal two phase flow

    E-Print Network [OSTI]

    Flores, Anita Elena

    2000-01-01T23:59:59.000Z

    the calibration coefficient (KY= flow coefficient (K) multiplied by the expansion factor (Y)), the Euler number, and the beta ratio. These results were analyzed to develop a calibration for the slotted orifice plate two-phase flow meter which can ultimately...

  2. Bernoulli Applications A Venturi meter is used to measure the flow rate through a tube.

    E-Print Network [OSTI]

    Weijgaert, Rien van de

    04/03/2014 1 Bernoulli Applications A Venturi meter is used to measure the flow rate through a tube: as the flow is horizontal, we do not have to take into account the gravity term. 2) Continuity equation-1822), an Italian physicist. Look at the construction in figure: - we assume the flow is smooth and effectively

  3. Social Network of Smart-Metered Homes and SMEs for Grid-based Renewable Energy Exchange

    E-Print Network [OSTI]

    Steels, Luc

    makes innovations on smart technologies and processes by building a demand- response decision support and aggregate data from multiple autonomous physical or virtual meters, and (iv) manage the actual energy demand and ensure the achievement of demand response for the community involved. The approach is centered

  4. Progress on the 1.6-meter New Solar Telescope at Big Bear Solar Observatory

    E-Print Network [OSTI]

    Progress on the 1.6-meter New Solar Telescope at Big Bear Solar Observatory C. Denkera, P. R, Newark, NJ 07102, U.S.A. bBig Bear Solar Observatory, 40386 North Shore Lane, Big Bear City, CA 92314, U.S.A. cSeoul National University, School of Earth and Environmental Science, Seoul, 151-742 Republic

  5. Optimal Integration of Renewable Energy Resources in Data Centers with Behind-the-Meter Renewable Generator

    E-Print Network [OSTI]

    Mohsenian-Rad, Hamed

    1 Optimal Integration of Renewable Energy Resources in Data Centers with Behind-the-Meter Renewable-- Renewable energy resources, such as wind and solar power, are rapidly becoming generation technologies-temporal variations, the integration of renewable energy resources is usually very challenging. Some of the previously

  6. Payment Matters? - An Exploratory Study into the Pre-Payment Electricity Metering

    E-Print Network [OSTI]

    Brutscher, Philipp-Bastian

    2011-02-10T23:59:59.000Z

    In this paper we look at the role of pre-payment (in the context of prepayment metering) for household electricity consumption. Using a matching approach, we find that households paying their electricity up-front tend to consume no less electricity...

  7. Energy Metering for Free: Augmenting Switching Regulators for Real-Time Monitoring

    E-Print Network [OSTI]

    Count, a new energy meter design. For many systems that have a built-in switching regulator, adding a single nearly linearly with load current for a variety of regulators. 1 The iCount Design Many battery a variety of regulator topologies (boost, buck, buck-boost), control modes (current-mode, voltage

  8. Performance Evaluation of Adaptive Ramp-Metering Algorithms Using Microscopic Traffic Simulation Model

    E-Print Network [OSTI]

    Levinson, David M.

    in the vicinity of the ramp. Examples of local traffic-responsive control are demand capacity, occupancy control and potential effectiveness of such algorithms depend on a number of complex factors that are best investigated-metering policies, implementations based on such develop- ments have been slow in coming. In practice, modes

  9. A Global Personal Energy Meter Simon Hay,Andrew Rice and Andy Hopper

    E-Print Network [OSTI]

    Cambridge, University of

    im- proved estimates by factoring in airline data. The energy consumption trace for an applianceCar: 40 kwH/d A Global Personal Energy Meter Simon Hay,Andrew Rice and Andy Hopper http of the Planet. Phil. Trans. R. Soc. A, 366(1881):3685--3697, October 2008. David JC MacKay. Sustainable Energy

  10. AgSec: Secure and Efficient CDMA-based Aggregation for Smart Metering Systems

    E-Print Network [OSTI]

    Namboodiri, Vinod

    ]. This will help the utility companies to act on consumer information gathered from smart meters (SM) at the user prices through dynamic pricing schemes, wide penetration of renewable resources such as wind and solar based on the appliance they are using [25]. Insurance companies can monitor and track eating, sleeping

  11. 1128 volume 27 number 12 december 2009 nature biotechnology square meter per day of algae containing

    E-Print Network [OSTI]

    Cai, Long

    1128 volume 27 number 12 december 2009 nature biotechnology square meter per day of algae, such as triglycerides from algae or cellulosic biomass from higher plants, as feedstocks for biofuel production. The algal program sought to develop high-oil-content algae that grow at very fast rates. In our report

  12. Gemini: A Non-Invasive, Energy-Harvesting True Power Meter Bradford Campbell and Prabal Dutta

    E-Print Network [OSTI]

    Dutta, Prabal

    measure voltage (since true power requires sample-by-sample multiplication of current and voltage to the voltage channel they can only measure apparent power, at best, and certainly not true power. A small capable of measuring true power. Two insights enable this design point: 1) a power meter can harvest

  13. Evaluating radial component current measurements from CODAR high frequency radars and moored in situ current meters

    E-Print Network [OSTI]

    California at Santa Barbara, University of

    error of 19o . The effects of bearing errors on total velocity vector estimates were evaluated usingEvaluating radial component current measurements from CODAR high frequency radars and moored of the moorings carried vector measuring current meters (VMCM's), the ninth an upward-looking acoustic Doppler

  14. Design rules for pumping and metering of highly viscous fluids in microfluidics

    E-Print Network [OSTI]

    Kenis, Paul J. A.

    Design rules for pumping and metering of highly viscous fluids in microfluidics Sarah L. Perry.1039/c0lc00035c The use of fluids that are significantly more viscous than water in microfluidics has a theoretical treatment for the flow of highly viscous fluids in deforming microfluidic channels, particularly

  15. Economic Implications of Net Metering for Stationary and Motor Vehicle Fuel Cell Systems in California

    E-Print Network [OSTI]

    Kammen, Daniel M.

    PWP-092 Economic Implications of Net Metering for Stationary and Motor Vehicle Fuel Cell Systems emissions, and petroleum use from motor vehicles, fuel cell vehicles (FCVs) could also act as distributed Fuel Cell Systems in California January 31, 2002 Dr. Timothy E. Lipman Ms. Jennifer L. Edwards Prof

  16. Micro-meter Crack Response to Rock Blast Vibrations, Wind Gusts & Weather Effects

    E-Print Network [OSTI]

    Micro-meter Crack Response to Rock Blast Vibrations, Wind Gusts & Weather Effects C. H. Dowding,1 effects. These measurements substantiate the conservancy of the 12.5 mm/s (0.5 in./s) blasting vibration blasting. Measurements in this case study now extend weather effects to include wind. While it has been

  17. On the Scalable Collection of Metering Data in Smart Grids through Message Concatenation

    E-Print Network [OSTI]

    Namboodiri, Vinod

    , demand-side management, to name a few. A big challenge for smart grid application scenarios issue of how to communicate and handle consumer data collected by electric utilities and manage limited center, as well as between the smart meter and consumer appliances, would be facilitated for demand

  18. Unified Architecture for Large-Scale Attested Metering Michael LeMay, George Gross, Carl A. Gunter, Sanjam Garg

    E-Print Network [OSTI]

    Gross, George

    Unified Architecture for Large-Scale Attested Metering Michael LeMay, George Gross, Carl A. Gunter introduce a secure architecture called an attested me- ter for advanced metering that supports large, if they are not based upon a secure system architecture, they could in fact become one of the grid's most significant

  19. Net Metering

    Broader source: Energy.gov [DOE]

    Net excess generation (NEG) is treated as a kilowatt-hour (kWh) credit or other compensation on the customer's following bill.* When an annual period ends, a utility will purchase unused credits...

  20. Net Metering

    Broader source: Energy.gov (indexed) [DOE]

    Regulatory Policies Act of 1978 (PURPA) - Usually at utility's avoided cost (a wholesale rate) or a negotiated rate * New Mexico o REC Ownership: Utility owns RECs o Net...

  1. Fission meter

    DOE Patents [OSTI]

    Rowland, Mark S. (Alamo, CA); Snyderman, Neal J. (Berkeley, CA)

    2012-04-10T23:59:59.000Z

    A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source.

  2. Remote metering

    E-Print Network [OSTI]

    Ingram, Henry Lee

    1929-01-01T23:59:59.000Z

    on page 15 of the lppendix. This agreemsnt granted to the Westin2house Electrio and Uanudacturing Company, for a consideration, the riQt to purchase at a definite price, any patent claims that . uight be granted, within sixty days after date of issue... one were the same and the method. of oper- ation wss the same, there was a vast difference 'cetwesn the german Patent snd. the applioation under consideration, so Letters patent h'o. 1, 688, 681 was issued. as of June 15, 1925, granting four claims...

  3. Net Metering

    Broader source: Energy.gov [DOE]

    '''''Note: In July 2012, the Public Utilities Commission of Ohio (PUCO) opened a docket ([http://dis.puc.state.oh.us/CaseRecord.aspx?CaseNo=12-2050-EL-ORD Case 12-0250-EL-RDR]) to review the net...

  4. The SNL100-01 blade : carbon design studies for the Sandia 100-meter blade.

    SciTech Connect (OSTI)

    Griffith, Daniel Todd

    2013-02-01T23:59:59.000Z

    A series of design studies to investigate the effect of carbon on blade weight and performance for large blades was performed using the Sandia 100-meter All-glass Baseline Blade design as a starting point. This document provides a description of the final carbon blade design, which is termed as SNL100-01. This report includes a summary of the design modifications applied to the baseline all-glass 100-meter design and a description of the NuMAD model files that are made publicly available. This document is intended primarily to be a companion document to the distribution of the NuMAD blade model files for SNL100-01.

  5. Deployment of High Resolution Real-Time Distribution Level Metering on Maui: Preprint

    SciTech Connect (OSTI)

    Bank, J.

    2013-01-01T23:59:59.000Z

    In order to support the ongoing Maui Smart Grid demonstration project advanced metering has been deployed at the distribution transformer level in Maui Electric Company's Kihei Circuit on the Island of Maui. This equipment has been custom designed to provide accurately time-stamped Phasor and Power Quality data in real time. Additionally, irradiance sensors have been deployed at a few selected locations in proximity to photovoltaic (PV) installations. The received data is being used for validation of existing system models and for impact studies of future system hardware. Descriptions of the hardware and its installation, and some preliminary metering results are presented. Real-time circuit visualization applications for the data are also under development.

  6. METER-SIZED MOONLET POPULATION IN SATURN'S C RING AND CASSINI DIVISION

    SciTech Connect (OSTI)

    Baillie, Kevin; Colwell, Joshua E. [Department of Physics, University of Central Florida, Orlando, FL 32816-2385 (United States); Esposito, Larry W. [Laboratory for Atmospheric and Space Physics, University of Colorado at Boulder, 392 UCB, Boulder, CO 80309-0392 (United States); Lewis, Mark C., E-mail: kevin.baillie@cea.fr [Department of Computer Science, Trinity University, One Trinity Place, San Antonio, TX 78212-7200 (United States)

    2013-06-01T23:59:59.000Z

    Stellar occultations observed by the Cassini Ultraviolet Imaging Spectrograph reveal the presence of transparent holes a few meters to a few tens of meters in radial extent in otherwise optically thick regions of the C ring and the Cassini Division. We attribute the holes to gravitational disturbances generated by a population of {approx}10 m boulders in the rings that is intermediate in size between the background ring particle size distribution and the previously observed {approx}100 m propeller moonlets in the A ring. The size distribution of these boulders is described by a shallower power-law than the one that describes the ring particle size distribution. The number and size distribution of these boulders could be explained by limited accretion processes deep within Saturn's Roche zone.

  7. Design of a Net-Metering and PV Exhibit for the 2005 Solar Decathlon

    SciTech Connect (OSTI)

    Wassmer, M.; Warner, C.

    2005-01-01T23:59:59.000Z

    In the 2005 Solar Decathlon competition, 19 collegiate teams will design, build, and operate grid-independent homes powered by photovoltaic (PV) arrays on the National Mall. The prominence of grid-interconnected systems in the marketplace has provided the impetus for the development of a net-metering exhibit to be installed and operated during the competition. The exhibit will inform the visiting public about PV basics and appropriate alternatives to grid-independent systems. It will consist of four interactive components. One will be designed to educate people about the principles of net metering using a small PV array, a grid-interactive inverter, and a variable load. Additional components of the exhibit will demonstrate the effects of orientation, cloud cover, and nighttime on performance. The nighttime component will discuss appropriate storage options for different applications.

  8. The Economic Value of PV and Net Metering to Residential Customers in California

    SciTech Connect (OSTI)

    Darghouth, Naim; Barbose, Galen; Wiser, Ryan

    2010-05-17T23:59:59.000Z

    In this paper, we analyze the bill savings from PV for residential customers of the California's two largest electric utilities, under existing net metering tariffs as well as under several alternative compensation mechanisms. We find that economic value of PV to the customer is dependent on the structure of the underlying retail electricity rate and can vary quite significantly from one customer to another. In addition, we find that the value of the bill savings from PV generally declines with PV penetration level, as increased PV generation tends to offset lower-priced usage. Customers in our sample from both utilities are significantly better off with net metering than with a feed-in tariff where all PV generation is compensated at long-run avoided generation supply costs. Other compensation schemeswhich allow customers to displace their consumption with PV generation within each hour or each month, and are also based on the avoided costs, yield similar value to the customer as net metering.

  9. A restructuring agenda for developing competitive retail electric markets that is based on a low-cost, real-time, smart-kilowatt-hour meter adapter

    SciTech Connect (OSTI)

    Chasek, N.E.

    1997-12-31T23:59:59.000Z

    This paper proposes six agenda items that should expedite a politically smooth transition into a most efficient economically viable market-driven public power system. The agenda would introduce: the virtual marketplace for retail electric power, smart meters, smart meter readers, near-real-time load balancing and load apportionment, advanced supply and demand or commodity-style pricing, and reliability metering.

  10. Economic and Conservation Evaluation of Capital Renovation Projects: Harlingen Irrigation District Cameron County No. 1 Canal Meters and Telemetry Equipment, Impervious-Lining of Delivery Canals, Pipelines Replacing Delivery Canals, and On-Farm Delivery-Site Meters

    E-Print Network [OSTI]

    Rister, M. Edward; Lacewell, Ronald D.; Sturdivant, Allen W.; Robinson, John R.C.; Popp, Michael C.; Ellis, John R.

    TR-202 October 2002 Economic and Conservation Evaluation of Capital Renovation Projects: Harlingen Irrigation District Cameron County No. 1 – Canal Meters and Telemetry Equipment, Impervious-Lining of Delivery Canals, Pipelines Replacing Delivery... Canals, and On-Farm Delivery-Site Meters M. Edward Rister Ronald D. Lacewell Allen W. Sturdivant John R. C. Robinson Michael C. Popp John R. Ellis Texas Water Resources Institute Texas A&M University TR-202 October 2002 Economic and Conservation...

  11. Sequential high temperature reduction, low temperature hydrolysis...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    high temperature reduction, low temperature hydrolysis for the regeneration of sulfated NOx trap catalysts. Sequential high temperature reduction, low temperature hydrolysis for...

  12. A Technique to Utilize Smart Meter Load Information for Adapting Overcurrent Protection for Radial Distribution Systems with Distributed Generations

    E-Print Network [OSTI]

    Ituzaro, Fred Agyekum

    2012-07-16T23:59:59.000Z

    overcurrent protection scheme to reduce the number of customers affected by faults in RDS with DGs. Further, a technique is presented that utilizes customers loading information from smart meters in AMI to improve the sensitivity of substation OC relays...

  13. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    SciTech Connect (OSTI)

    Darghouth, Naim; Barbose, Galen; Wiser, Ryan

    2010-03-30T23:59:59.000Z

    Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption. Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). While net metering has played an important role in jump-starting the residential PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings varies under net metering, and how the bill savings under net metering compares to other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE). The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state.

  14. Verifying energy savings with minimal metered data: The Hunter heat pump analysis

    SciTech Connect (OSTI)

    Parker, S.A.

    1995-03-01T23:59:59.000Z

    In November 1992, Hunter Army Air Field (AAF) completed the installation of 489 air-source heat pumps -- a new heat pump and air-handling unit for each residence. The air-source heat pumps replaced older, less efficient, air-conditioning systems, fuel oil-fired furnaces, and fan coil units. Hunter AAF originally contacted to upgrade the old family housing heating, ventilating, and air-conditioning (HVAC) systems with high efficiency air-conditioning systems and natural gas furnaces, but an alternative proposal and following energy studies indicated that heat pumps were a more life-cycle cost-effective alternative. Six months after the heat pumps were installed, Hunter`s energy bills appeared to be increasing, not decreasing as expected. In early 1994, Pacific Northwest Laboratory` (PNL) began an analysis to determine if there were any energy savings resulting from the heat pump installation as predicted by previous energy studies. The problem is that the HVAC systems are not specifically submetered to support verifying the resulting energy savings and, as is the case with most federal facilities, even the homes are not individually metered. Savings verification needed to be accomplished with die existing and available metered data. This data consisted primarily of monthly electric submeter readings from the two housing subdivision meters, historical fuel oil delivery records for family housing, and monthly base-wide electric bills. The objective of the study is to verify the change in energy consumption in family housing and, to the extent possible, identify how much of the change in consumption is attributable to the new HVAC system and how much is probably attributable to other factors, such as the weather.

  15. A microprocessor control device for a neutron water content meter for powders

    SciTech Connect (OSTI)

    Stroikovskii, A.K.; Pershin, A.A.; Pronyakin, V.A.; Savelov, V.D.

    1985-08-01T23:59:59.000Z

    This paper examines two types of neutron gauges developed by the Special Designs Office of the Chermetavtomatika Production Cooperative: the VNS-7205 for iron-ore concentrate on conveyers and the VNS-7206 for loaded blast-furnace coke, both of which are fitted with a standard microprocessor device. This microprocessor provides a universal device, whose logarithm can be adjusted by software. One writes a program appropriate to the measurement conditions and material, which is held in a read-only memory, which may for example be electrically burned in. The microprocessor completely automates the calibration. The economic effect from introducing the meter with microprocessor control is 40,000 rubles.

  16. A study of the Antilles Current using moored current meter arrays

    E-Print Network [OSTI]

    Maloney, William Everett

    1967-01-01T23:59:59.000Z

    characteristics of the Savcnius rotor have been reported previously by Gaul (1962). The output from the current meter is a ro11 of 16 mm photographic film containing current direction and speed data, data on case inclination, and timing pulses. An example... the summer npeia ions, wind directions and speeds were typical for this subtropical latitude being gener;illy out of the east at Table 2. Mooring nositioning data. oorlpg; I I IFix No. !:Date, " Time I !I, " L'ST :I ~L*'- 0. ! I ILongitude Il...

  17. Effects of geometric scaling on static pressure measurements in orifice flow-meters

    E-Print Network [OSTI]

    Sarker, Arunava

    1993-01-01T23:59:59.000Z

    of the flange tap in typical orifice meters on pipes of different sizes. This was accomplished by comparing the static pressure distribution in a 60. 96 cm (2 foot) diameter orifice run to that on a 5. 08 cm (2 inch) diameter orifice run using air... at a Reynolds number of 122800 exceeded 200 m/s. This was above Mach 0. 6 which exceeds the API standards. The information obtained on the static pressure distributions in the 60. 96 cm (2 foot) and 5. 08 cm (2 inch) run were non...

  18. Flow Measurement with Tangential Paddlewheel Flow Meters: Analysis of Experimental Results and in-situ Diagnostics

    E-Print Network [OSTI]

    Watt, J. B.; Haberl, J. S.

    the premature drop-out of magnetic-type tangential paddlewheel sensors, as well as several in-situ diagnostic measures for ascertaining whether or not a flow meter is experiencing turbulent conditions or if a flow sensor's output signal is suffering a degraded... per second for magnetic-type, and 0.5 to 2 feet per second for non-magnetic-type flow sensors deviated from the actual flow by 20% or more which makes the measurement of flow and thermal energy use in this regime highly suspect. Figure 4 also indicates...

  19. Deployment of Behind-The-Meter Energy Storage for Demand Charge Reduction

    SciTech Connect (OSTI)

    Neubauer, J.; Simpson, M.

    2015-01-01T23:59:59.000Z

    This study investigates how economically motivated customers will use energy storage for demand charge reduction, as well as how this changes in the presence of on-site photovoltaic power generation, to investigate the possible effects of incentivizing increased quantities of behind-the-meter storage. It finds that small, short-duration batteries are most cost effective regardless of solar power levels, serving to reduce short load spikes on the order of 2.5% of peak demand. While profitable to the customer, such action is unlikely to adequately benefit the utility as may be desired, thus highlighting the need for modified utility rate structures or properly structured incentives.

  20. Tips: Smart Meters and a Smarter Power Grid | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you sure you want toworldPower 2010 1 TNews &Appliances Tips:Smart Meters

  1. Property:OpenEI/UtilityRate/UseNetMetering | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere I Geothermal PwerPerkinsInformationInformation FixedDemandChargeMonth8FlatDemandMonth7UseNetMetering

  2. PHY and MAC Layer Design of Hybrid Spread Spectrum Based Smart Meter Network

    SciTech Connect (OSTI)

    Kuruganti, Phani Teja [ORNL] [ORNL

    2012-01-01T23:59:59.000Z

    The smart grid is a combined process of revitalizing the traditional power grid applications and introducing new applications to improve the efficiency of power generation, transmission and distribution. This can be achieved by leveraging advanced communication and networking technologies. Therefore the selection of the appropriate communication technology for different smart grid applications has been debated a lot in the recent past. After comparing different possible technologies, a recent research study has arrived at a conclusion that the 3G cellular technology is the right choice for distribution side smart grid applications like smart metering, advanced distribution automation and demand response management system. In this paper, we argue that the current 3G/4G cellular technologies are not an appropriate choice for smart grid distribution applications and propose a Hybrid Spread Spectrum (HSS) based Advanced Metering Infrastructure (AMI) as one of the alternatives to 3G/4G technologies. We present a preliminary PHY and MAC layer design of a HSS based AMI network and evaluate their performance using matlab and NS2 simulations. Also, we propose a time hierarchical scheme that can significantly reduce the volume of random access traffic generated during blackouts and the delay in power outage reporting.

  3. Designing and Operating Through Compromise: Architectural Analysis of CKMS for the Advanced Metering Infrastructure

    SciTech Connect (OSTI)

    Duren, Mike [Sypris Electronics, LLC] [Sypris Electronics, LLC; Aldridge, Hal [ORNL] [ORNL; Abercrombie, Robert K [ORNL] [ORNL; Sheldon, Frederick T [ORNL] [ORNL

    2013-01-01T23:59:59.000Z

    Compromises attributable to the Advanced Persistent Threat (APT) highlight the necessity for constant vigilance. The APT provides a new perspective on security metrics (e.g., statistics based cyber security) and quantitative risk assessments. We consider design principals and models/tools that provide high assurance for energy delivery systems (EDS) operations regardless of the state of compromise. Cryptographic keys must be securely exchanged, then held and protected on either end of a communications link. This is challenging for a utility with numerous substations that must secure the intelligent electronic devices (IEDs) that may comprise complex control system of systems. For example, distribution and management of keys among the millions of intelligent meters within the Advanced Metering Infrastructure (AMI) is being implemented as part of the National Smart Grid initiative. Without a means for a secure cryptographic key management system (CKMS) no cryptographic solution can be widely deployed to protect the EDS infrastructure from cyber-attack. We consider 1) how security modeling is applied to key management and cyber security concerns on a continuous basis from design through operation, 2) how trusted models and key management architectures greatly impact failure scenarios, and 3) how hardware-enabled trust is a critical element to detecting, surviving, and recovering from attack.

  4. 80 and 100 Meter Wind Energy Resource Potential for the United States (Poster)

    SciTech Connect (OSTI)

    Elliott, D.; Schwartz, M.; Haymes, S.; Heimiller, D.; Scott, G.; Flowers, L.; Brower, M.; Hale, E.; Phelps, B.

    2010-05-01T23:59:59.000Z

    Accurate information about the wind potential in each state is required for federal and state policy initiatives that will expand the use of wind energy in the United States. The National Renewable Energy Laboratory (NREL) and AWS Truewind have collaborated to produce the first comprehensive new state-level assessment of wind resource potential since 1993. The estimates are based on high-resolution maps of predicted mean annual wind speeds for the contiguous 48 states developed by AWS Truewind. These maps, at spatial resolution of 200 meters and heights of 60 to 100 meters, were created with a mesoscale-microscale modeling technique and adjusted to reduce errors through a bias-correction procedure involving data from more than 1,000 measurement masts. NREL used the capacity factor maps to estimate the wind energy potential capacity in megawatts for each state by capacity factor ranges. The purpose of this presentation is to (1) inform state and federal policy makers, regulators, developers, and other stakeholders on the availability of the new wind potential information that may influence development, (2) inform the audience of how the new information was derived, and (3) educate the audience on how the information should be interpreted in developing state and federal policy initiatives.

  5. A Near-Infrared Spectroscopic Survey at the SDSS 2.5-meter Telescope?

    E-Print Network [OSTI]

    Skrutskie, Michael F

    2015-01-01T23:59:59.000Z

    We are posting this 10-year-old white paper to support an upcoming survey description paper for the SDSS-III Apache Point Galactic Evolution Experiment (APOGEE) led by PI Dr. Steven Majewski. The white paper presented here was a contribution to a 2005 "futures" planning process for the Astrophysical Research Consortium led by Dr. Donald York that examined both prospects for extending the work of SDSS and SDSS-II as well as enhancing the capabilities of the Apache Point 3.5-meter telescope and the overall scientific reach of the Consortium. This particular white paper describes the potential for using the Sloan 2.5-meter telescope and its fiber optic infrastructure to conduct a galactic plane chemical abundance survey in the low-extinction 1.6um H-band. The survey would target >1000 red giant stars per night selected from the Two Micron All Sky Survey using a >200 fiber near-infrared spectrograph operating at spectral resolution of R~24,000 with a magnitude limit of H~12 - very close to the final APOGEE implem...

  6. Analysis of PG E's residential end-use metered data to improve electricity demand forecasts

    SciTech Connect (OSTI)

    Eto, J.H.; Moezzi, M.M.

    1992-06-01T23:59:59.000Z

    It is generally acknowledged that improvements to end-use load shape and peak demand forecasts for electricity are limited primarily by the absence of reliable end-use data. In this report we analyze recent end-use metered data collected by the Pacific Gas and Electric Company from more than 700 residential customers to develop new inputs for the load shape and peak demand electricity forecasting models used by the Pacific Gas and Electric Company and the California Energy Commission. Hourly load shapes are normalized to facilitate separate accounting (by the models) of annual energy use and the distribution of that energy use over the hours of the day. Cooling electricity consumption by central air-conditioning is represented analytically as a function of climate. Limited analysis of annual energy use, including unit energy consumption (UEC), and of the allocation of energy use to seasons and system peak days, is also presented.

  7. The RCT 1.3-meter Robotic Telescope: Broad-band Color Transformation and Extinction Calibration

    E-Print Network [OSTI]

    Strolger, Louis-Gregory; Carini, Michael; Engle, Scott; Gelderman, Richard; Guinan, Edward; Laney, C David; McGruder, Charles; Treffers, Richard R; Walter, Donald K

    2013-01-01T23:59:59.000Z

    The RCT 1.3-meter telescope, formerly known as the Kitt Peak National Observatory (KPNO) 50-inch telescope, has been refurbished as a fully robotic telescope, using an autonomous scheduler to take full advantage of the observing site without the requirement of a human presence. Here we detail the current configuration of the RCT, and present as a demonstration of its high-priority science goals, the broadband {\\it UBVRI} photometric calibration of the optical facility. In summary, we find the linear color transformation and extinction corrections to be consistent with similar optical KPNO facilities, to within a photometric precision of 10% (at $1\\sigma$). While there were identified instrumental errors likely adding to the overall uncertainty, associated with since-resolved issues in engineering and maintenance of the robotic facility, a preliminary verification of this calibration gave good indication that the solution is robust, perhaps to a higher precision than this initial calibration implies. The RCT h...

  8. Metering Best Practices, A Guide to Achieving Utility Resource Efficiency, Release 2.0

    SciTech Connect (OSTI)

    Sullivan, Greg; Hunt, W. D.; Pugh, Ray; Sandusky, William F.; Koehler, Theresa M.; Boyd, Brian K.

    2011-08-31T23:59:59.000Z

    This release is an update and expansion of the information provided in Release 1.0 of the Metering Best Practice Guide that was issued in October 2007. This release, as was the previous release, was developed under the direction of the U.S. Department of Energy's Federal Energy Management Program (FEMP). The mission of FEMP is to facilitate the Federal Government's implementation of sound cost-effective energy management and investment practices to enhance the nation's energy security and environmental stewardship. Each of these activities is directly related to achieving requirements set forth in the Energy Policy Acts of 1992 and 2005, the Energy Independence and Security Act (EISA) of 2007, and the goals that have been established in Executive Orders 13423 and 13514 - and also those practices that are inherent in sound management of Federal financial and personnel resources.

  9. Loch Linnhe `94: Current meter array operations and on-site analysis

    SciTech Connect (OSTI)

    Chambers, D.H.; Jones, H.E.

    1995-08-11T23:59:59.000Z

    This report documents the operation and on-site data analysis of the LLNL Current Meter Array (CMA) which was fielded at Loch Linnhe `94. The CMA is a large floating array of 10 sensors which measure horizontal current near the water surface. The measurements are used to interpret radar images of the water surface. This experiment was conducted as a part of the Joint UK/US Radar Ocean Imaging (ROI) Program. It was held at Loch Linnhe, Scotland in September 1994. The experiment consisted of measuring natural and ship-generated internal waves (IWs) in Loch Linnhe and imaging them with a land-based, dual frequency, dual-polarization real aperture radar operated by the UK. The goal was to determine the relationship between the amplitude of IWs as measured by instrumentation deployed in the water and the modulation they produce in radar images of the water surface.

  10. Evaluation of a portable x-ray fluorescence survey meter for the quantitative determination of trace metals in welding fumes 

    E-Print Network [OSTI]

    Fehrenbacher, Mary Catherine

    1984-01-01T23:59:59.000Z

    EVALUATION OF A PORTABLE X-RAY FLUORE~ SURVEY METER FOR TIIE QUANTITATIVE DEPERMINATI(gq OF TRACE METALS IN WELDING FIJvtES A THESIS by MARY CATHERINE FEHRENBACHER Submitted to the Graduate College of Texas A%M University in partial... fulfillment of the requirement for the degree of MASTER OF SCIENCE May, 1984 MAJOR SUBJECI': INDUSTRIAL HYGIENE EVALUATION OF A PORTABLE X-RAY FLUORES~ SURVEY METER FOR THE QUANTITATIVE DETERMINATIGN OF TRACE METALS IN WELDING FIJvtES A THESIS by h...

  11. We got a new digital electric meter. Our usage went up 123%. Our Bill went up 65%

    SciTech Connect (OSTI)

    Honebein, Peter C.

    2010-03-15T23:59:59.000Z

    There is no question that smart meters are a benefit to utilities, in terms of operational efficiency. But headlines like this one are frightening. They suggest a significant misunderstanding of the technology, marketing, and customer experience surrounding this worthwhile innovation. (author)

  12. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    SciTech Connect (OSTI)

    Energy and Resources Group, University of California, Berkeley; Darghouth, Naim R.; Barbose, Galen; Wiser, Ryan

    2011-06-01T23:59:59.000Z

    Net metering has become a widespread mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), but has faced challenges as PV installations grow to a larger share of generation in a number of states. This paper examines the value of the bill savings that customers receive under net metering, and the associated role of retail rate design, based on a sample of approximately two hundred residential customers of California's two largest electric utilities. We find that the bill savings per kWh of PV electricity generated varies by more than a factor of four across the customers in the sample, which is largely attributable to the inclining block structure of the utilities' residential retail rates. We also compare the bill savings under net metering to that received under three potential alternative compensation mechanisms, based on California's Market Price Referent (MPR). We find that net metering provides significantly greater bill savings than a full MPR-based feed-in tariff, but only modestly greater savings than alternative mechanisms under which hourly or monthly net excess generation is compensated at the MPR rate.

  13. First Light of the 1.6 meter off-axis New Solar Telescope at Big Bear Solar Observatory

    E-Print Network [OSTI]

    -axis configurations, the NST adopts a unique off-axis optical design. Since the Secondary Mirror (SM) and SM supportFirst Light of the 1.6 meter off-axis New Solar Telescope at Big Bear Solar Observatory Wenda Caoab, Nicolas Gorceixb, Roy Coulterb, Aaron Coulterb, Philip R. Goodeab aCenter for Solar-Terrestrial Research

  14. Study about the flashing process through a metering expansion valve Mohammed Ait Bahajji, Jose M. Corberan *, Javier Urchueguia,

    E-Print Network [OSTI]

    Fernández de Córdoba, Pedro

    Study about the flashing process through a metering expansion valve Mohammed Ait Bahajji, Jose´ M- sion valve, are presented and discussed. The results involved the measurement at different lifts of the flow-rate flowing through the valve for three different refrigerants R22, R290 (propane) and R410A

  15. Development and evaluation of operational strategies for providing an integrated diamond interchange ramp-metering control system

    E-Print Network [OSTI]

    Tian, Zongzhong

    2004-09-30T23:59:59.000Z

    -to-capacity ratios at the metered ramps. The results of the evaluation indicate that the integrated operations through an adaptive signal control system were most effective under the medium traffic demand scenario by preventing or delaying the onset of ramp...

  16. Cornell's Ranger robot navigated 108.5 times around the Barton Hall indoor track, about 212 meters pe Entertainment

    E-Print Network [OSTI]

    Ruina, Andy L.

    . Unlike other walking robots that use motors to control every movement, the Ranger appears more relaxed could be applied to rehabilitation, prostheses for humans and improving athletic performance. New 6Cornell's Ranger robot navigated 108.5 times around the Barton Hall indoor track, about 212 meters

  17. Heat flow and subsurface temperature distributions in central and western New York. Final report

    SciTech Connect (OSTI)

    Hodge, D.S.; Fromm, K.

    1984-01-01T23:59:59.000Z

    Initiation of a geothermal energy program in western and central New York requires knowledge of subsurface temperatures for targeting areas of potential resources. The temperature distribution in possible geothermal reservoirs, calculated from heat flow measurements and modeling techniques, shows that a large area of New York can be considered for exploitation of geothermal resources. Though the temperatures at currently accessible depths show the availability of only a low-temperature (less than 100/sup 0/C), direct-use resource, this can be considered as an alternative for the future energy needs of New York State. From analysis of bottom-hole-temperature data and direct heat flow measurements, estimates of temperatures in the Cambrian Sandstones provide the basis of the economic evaluation of the reservoir. This reservoir contains the extractable fluids needed for targeting a potential geothermal well site in the low-temperature geothermal target zone. In the northern section of the Appalachian basin, reservoir temperatures in the Cambrian are below 50/sup 0/C but may be over 80/sup 0/C in the deeper parts of the basin in southern New York State. Using a minimum of 50/sup 0/C as a useful reservoir temperature, temperatures in excess of this value are encountered in the Theresa Formation at depths in excess of 1300 meters. Considering a maximum depth for economical drilling to be 2500 meters with present technology, the 2500 meters to the Theresa (sea level datum) forms the lower limit of the geothermal resource. Temperatures in the range of 70/sup 0/C to 80/sup 0/C are predicted for the southern portion of New York State.

  18. Insights from Smart Meters: The Potential for Peak-Hour Savings from Behavior-Based Programs

    SciTech Connect (OSTI)

    Todd, Annika; Perry, Michael; Smith, Brian; Sullivan, Michael; Cappers, Peter; Goldman, Charles

    2014-03-25T23:59:59.000Z

    The rollout of smart meters in the last several years has opened up new forms of previously unavailable energy data. Many utilities are now able in real-time to capture granular, household level interval usage data at very high-frequency levels for a large proportion of their residential and small commercial customer population. This can be linked to other time and locationspecific information, providing vast, constantly growing streams of rich data (sometimes referred to by the recently popular buzz word, “big data”). Within the energy industry there is increasing interest in tapping into the opportunities that these data can provide. What can we do with all of these data? The richness and granularity of these data enable many types of creative and cutting-edge analytics. Technically sophisticated and rigorous statistical techniques can be used to pull interesting insights out of this highfrequency, human-focused data. We at LBNL are calling this “behavior analytics”. This kind of analytics has the potential to provide tremendous value to a wide range of energy programs. For example, highly disaggregated and heterogeneous information about actual energy use would allow energy efficiency (EE) and/or demand response (DR) program implementers to target specific programs to specific households; would enable evaluation, measurement and verification (EM&V) of energy efficiency programs to be performed on a much shorter time horizon than was previously possible; and would provide better insights in to the energy and peak hour savings associated with specifics types of EE and DR programs (e.g., behavior-based (BB) programs). In this series, “Insights from Smart Meters”, we will present concrete, illustrative examples of the type of value that insights from behavior analytics of these data can provide (as well as pointing out its limitations). We will supply several types of key findings, including: • Novel results, which answer questions the industry previously was unable to answer; • Proof-of-concept analytics tools that can be adapted and used by others; and • Guidelines and protocols that summarize analytical best practices. This report focuses on one example of the kind of value that analysis of this data can provide: insights into whether behavior-based (BB) efficiency programs have the potential to provide peak-hour energy savings.

  19. SMART-X, "Square Meter, Arcsecond Resolution X-ray Telescope" A. Vikhlinina, P. Reida, H. Tananbauma, D. A. Schwartza, W. R. Formana, C. Jonesa, J. Bookbindera,

    E-Print Network [OSTI]

    SMART-X, "Square Meter, Arcsecond Resolution X-ray Telescope" A. Vikhlinina, P. Reida, HJohn Hopkins University, 3400 North Charles Street Baltimore, MD 21211 ABSTRACT SMART-X is a mission concept microcalorimeter, 22 FOV imager, and high-throughput gratings. 1. OVERVIEW We describe the Square Meter Arcsecond

  20. Abstract--Commercial-off-the-shelf (COTS) components were tested over the Martian temperature range for their use in a

    E-Print Network [OSTI]

    Kuhn, William B.

    supplies and multi meter using IEEE GPIB- 488 standard for data acquisition. Measurements were then taken TESTING Cryogenic cooling is a process of bringing down the temperature of the DUT (Device under Test to vapor state and thus the idea behind cryogenic cooling is to make a liquid vaporize and thus cool

  1. Interlaboratory comparison of four heat flow meter apparatuses on planed polyisocyanurate boards foamed with CFC-11

    SciTech Connect (OSTI)

    Graves, R.S.; McElroy, D.L. (Oak Ridge National Lab., TN (USA)); Miller, R.G. (Walter (Jim) Research Corp., St. Petersburg, FL (USA)); Yarbrough, D.W. (Tennessee Technological Univ., Cookeville, TN (USA)); Zarr, R.R. (National Inst. of Standards and Technology, Gaithersburg, MD (USA))

    1991-06-01T23:59:59.000Z

    This report describes an interlaboratory comparison of apparent thermal conductivity (k) results on planed polyisocyanurate (PIR) boards foamed with chlorofluorocarbon-11 (CFC-11). Sequential tests were conducted at 75{degrees}F (24{degrees}C) at four facilities on two rigid (PIR) boards, individually and as a pair, using four comparative heat flow meter apparatuses. The specimens were shipped from lab to lab, and testing yielded 15 k-values that have two standard deviation (2 {alpha}) value of 2.2% when described by: k(Btu{center dot}in./h{center dot}ft{sup 2}{center dot}F) = 0/1365 + 1.15 {times} 10{sup {minus}4} t k(W/m{center dot}K) = 0.0197 + 1.66 {times} 10{sup {minus}5} t, where t is the elapsed time in days after planing of the boards. An increased 2 {sigma} value for board 2 may be associated with a larger variation in thickness. The 15 thermal conductance (C) values have a 2 {sigma} value of 3.2% when described by: C(Btu/H{center dot}h{center dot}{sup 2}{center dot}{degrees}F) = 0.1069 + 1.20 {times} 10{sup {minus}4} t. Thus, the 2 {sigma} (k-values) of the interlaboratory comparison is not reduced by comparing C values. 5 refs., 1 fig., 8 tabs.

  2. Heralded entanglement between solid-state qubits separated by 3 meters

    E-Print Network [OSTI]

    H. Bernien; B. Hensen; W. Pfaff; G. Koolstra; M. S. Blok; L. Robledo; T. H. Taminiau; M. Markham; D. J. Twitchen; L. Childress; R. Hanson

    2012-12-26T23:59:59.000Z

    Quantum entanglement between spatially separated objects is one of the most intriguing phenomena in physics. The outcomes of independent measurements on entangled objects show correlations that cannot be explained by classical physics. Besides being of fundamental interest, entanglement is a unique resource for quantum information processing and communication. Entangled qubits can be used to establish private information or implement quantum logical gates. Such capabilities are particularly useful when the entangled qubits are spatially separated, opening the opportunity to create highly connected quantum networks or extend quantum cryptography to long distances. Here we present a key experiment towards the realization of long-distance quantum networks with solid-state quantum registers. We have entangled two electron spin qubits in diamond that are separated by a three-meter distance. We establish this entanglement using a robust protocol based on local creation of spin-photon entanglement and a subsequent joint measurement of the photons. Detection of the photons heralds the projection of the spin qubits onto an entangled state. We verify the resulting non-local quantum correlations by performing single-shot readout on the qubits in different bases. The long-distance entanglement reported here can be combined with recently achieved initialization, readout and entanglement operations on local long-lived nuclear spin registers, enabling deterministic long-distance teleportation, quantum repeaters and extended quantum networks.

  3. High Temperatures & Electricity Demand

    E-Print Network [OSTI]

    High Temperatures & Electricity Demand An Assessment of Supply Adequacy in California Trends.......................................................................................................1 HIGH TEMPERATURES AND ELECTRICITY DEMAND.....................................................................................................................7 SECTION I: HIGH TEMPERATURES AND ELECTRICITY DEMAND ..........................9 BACKGROUND

  4. Status Report on the Passive Neutron Enrichment Meter (PNEM) for UF6 Cylinder Assay

    SciTech Connect (OSTI)

    Miller, Karen A. [Los Alamos National Laboratory; Swinhoe, Martyn T. [Los Alamos National Laboratory; Menlove, Howard O. [Los Alamos National Laboratory; Marlow, Johnna B. [Los Alamos National Laboratory

    2012-05-02T23:59:59.000Z

    The Passive Neutron Enrichment Meter (PNEM) is a nondestructive assay (NDA) system being developed at Los Alamos National Laboratory (LANL). It was designed to determine {sup 235}U mass and enrichment of uranium hexafluoride (UF{sub 6}) in product, feed, and tails cylinders (i.e., 30B and 48Y cylinders). These cylinders are found in the nuclear fuel cycle at uranium conversion, enrichment, and fuel fabrication facilities. The PNEM is a {sup 3}He-based neutron detection system that consists of two briefcase-sized detector pods. A photograph of the system during characterization at LANL is shown in Fig. 1. Several signatures are currently being studied to determine the most effective measurement and data reduction technique for unfolding {sup 235}U mass and enrichment. The system collects total neutron and coincidence data for both bare and cadmium-covered detector pods. The measurement concept grew out of the success of the Uranium Cylinder Assay System (UCAS), which is an operator system at Rokkasho Enrichment Plant (REP) that uses total neutron counting to determine {sup 235}U mass in UF{sub 6} cylinders. The PNEM system was designed with higher efficiency than the UCAS in order to add coincidence counting functionality for the enrichment determination. A photograph of the UCAS with a 48Y cylinder at REP is shown in Fig. 2, and the calibration measurement data for 30B product and 48Y feed and tails cylinders is shown in Fig. 3. The data was collected in a low-background environment, meaning there is very little scatter in the data. The PNEM measurement concept was first presented at the 2010 Institute of Nuclear Materials Management (INMM) Annual Meeting. The physics design and uncertainty analysis were presented at the 2010 International Atomic Energy Agency (IAEA) Safeguards Symposium, and the mechanical and electrical designs and characterization measurements were published in the ESARDA Bulletin in 2011.

  5. Energy Doubling of 42 GeV Electrons in a Meter-scale Plasma Wakefield Accelerator

    SciTech Connect (OSTI)

    Blumenfeld, Ian; Clayton, Christopher E.; Decker, Franz-Josef; Hogan, Mark J.; Huang, Chengkun; Ischebeck, Rasmus; Iverson, Richard; Joshi, Chandrashekhar; Katsouleas,; Kirby, Neil; Lu, Wei; Marsh, Kenneth A.; Mori, Warren B.; Muggli, Patric; Oz, Erdem; Siemann, Robert H.; Walz, Dieter; Zhou, Miaomiao; /SLAC /UCLA /Southern California U.

    2007-03-14T23:59:59.000Z

    The energy frontier of particle physics is several trillion electron volts, but colliders capable of reaching this regime (such as the Large Hadron Collider and the International Linear Collider) are costly and time-consuming to build; it is therefore important to explore new methods of accelerating particles to high energies. Plasma-based accelerators are particularly attractive because they are capable of producing accelerating fields that are orders of magnitude larger than those used in conventional colliders. In these accelerators, a drive beam (either laser or particle) produces a plasma wave (wakefield) that accelerates charged particles. The ultimate utility of plasma accelerators will depend on sustaining ultrahigh accelerating fields over a substantial length to achieve a significant energy gain. Here we show that an energy gain of more than 42 GeV is achieved in a plasma wakefield accelerator of 85 cm length, driven by a 42 GeV electron beam at the Stanford Linear Accelerator Center (SLAC). The results are in excellent agreement with the predictions of three-dimensional particle-in-cell simulations. Most of the beam electrons lose energy to the plasma wave, but some electrons in the back of the same beam pulse are accelerated with a field of {approx} 52GV m{sup -1}. This effectively doubles their energy, producing the energy gain of the 3-km-long SLAC accelerator in less than a meter for a small fraction of the electrons in the injected bunch. This is an important step towards demonstrating the viability of plasma accelerators for high-energy physics applications.

  6. Report of Energy Efficiency Study and Metering/Utilities Profile for Electricity Deregulation at Texas A&M University -- Galveston (TAMU-G) Galveston, Texas

    E-Print Network [OSTI]

    Zhu, Y.; Turner, W. D.; Claridge, D. E.

    1999-01-01T23:59:59.000Z

    ESL-TR-99/12-05 Report of Energy Efficiency Study and Metering/Utilities Profile for Electricity Deregulation at the Texas A&M University at Galveston (TAMU-G) Galveston, Texas Submitted to Texas A&M University at Galveston The Texas A&M University... to the Community College, we have not included it as a potential commissioning site. We did also do a commissioning audit of the TEEX Bayou Building as part of the study. Metering Recommendations for Electric Deregulation Several options exist -reinstall ESL meters...

  7. DESIGN OF INTELLIGENT CONDUCTIVITY METER BASED ON MSP430F149

    E-Print Network [OSTI]

    , water quality had become a hot issue in the fields of clean drinking water, distilled water, medicinal. The water quality problem was associated with both physical and chemical problems such as too high or too and take temperature compensation. It adopted bipolar pulse excitation signal to avoid the electrode

  8. Use of Metering for Facility and Whole Building Energy Analysis by the U.S. Depratment of Energy Federal Energy Management Program

    E-Print Network [OSTI]

    Devine, K. D.; Mazzucchi, R. P.

    1989-01-01T23:59:59.000Z

    This paper details how the U.S. Department of Energy, Federal Energy Management Program (FEMP) is applying metering technology to conduct empirically based analyses o f energy use by federal agencies. Continuing developments in sensors, data...

  9. Using electrical resistance tomography to map subsurface temperatures

    DOE Patents [OSTI]

    Ramirez, Abelardo L. (Pleasanton, CA); Chesnut, Dwayne A. (San Francisco, CA); Daily, William D. (Livermore, CA)

    1994-01-01T23:59:59.000Z

    A method is provided for measuring subsurface soil or rock temperatures remotely using electrical resistivity tomography (ERT). Electrical resistivity measurements are made using electrodes implanted in boreholes driven into the soil and/or at the ground surface. The measurements are repeated as some process changes the temperatures of the soil mass/rock mass. Tomographs of electrical resistivity are calculated based on the measurements using Poisson's equation. Changes in the soil/rock resistivity can be related to changes in soil/rock temperatures when: (1) the electrical conductivity of the fluid trapped in the soil's pore space is low, (2) the soil/rock has a high cation exchange capacity and (3) the temperature changes are sufficiently high. When these three conditions exist the resistivity changes observed in the ERT tomographs can be directly attributed to changes in soil/rock temperatures. This method provides a way of mapping temperature changes in subsurface soils remotely. Distances over which the ERT method can be used to monitor changes in soil temperature range from tens to hundreds of meters from the electrode locations.

  10. Using electrical resistance tomography to map subsurface temperatures

    DOE Patents [OSTI]

    Ramirez, A.L.; Chesnut, D.A.; Daily, W.D.

    1994-09-13T23:59:59.000Z

    A method is provided for measuring subsurface soil or rock temperatures remotely using electrical resistivity tomography (ERT). Electrical resistivity measurements are made using electrodes implanted in boreholes driven into the soil and/or at the ground surface. The measurements are repeated as some process changes the temperatures of the soil mass/rock mass. Tomographs of electrical resistivity are calculated based on the measurements using Poisson's equation. Changes in the soil/rock resistivity can be related to changes in soil/rock temperatures when: (1) the electrical conductivity of the fluid trapped in the soil's pore space is low, (2) the soil/rock has a high cation exchange capacity and (3) the temperature changes are sufficiently high. When these three conditions exist the resistivity changes observed in the ERT tomographs can be directly attributed to changes in soil/rock temperatures. This method provides a way of mapping temperature changes in subsurface soils remotely. Distances over which the ERT method can be used to monitor changes in soil temperature range from tens to hundreds of meters from the electrode locations. 1 fig.

  11. EVALUATION OF A TURBIDITY METER FOR USE AT THE DEFENSE WASTE PROCESSING FACILITY

    SciTech Connect (OSTI)

    Mahannah, R.; Edwards, T.

    2013-06-04T23:59:59.000Z

    Savannah River Remediation’s (SRR’s) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a “peanut” vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 weight percent (wt%). A “go/no-go” decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a “go” decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a “no-go” determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. Subsequent to the issuance of the initial version of this report but under the scope of the original request for technical assistance, WSE asked for this report to be revised to include the “go/no-go” CU value corresponding to 0.28 wt% solids. It was this request that led to the preparation of Revision 1 of the report. The results for the 0.28 wt% solids value were developed following the same approach as that utilized for the 0.14 wt% solids value. A sludge simulant was used to develop standards for testing both Optek units and to determine the viability of a “go/no-go” CU response for each of the units. Statistical methods were used by SRNL to develop the critical CU value for the “go/no-go” decision for these standards for each Optek unit. Since only one sludge simulant was available for this testing, the sensitivity of these results to other simulants and to actual sludge material is not known. However, limited testing with samples from the actual DWPF process (both SRAT product samples and SMECT samples) demonstrated that the use of the “go/no-go” criteria developed from the sludge simulant testing was conservative for these samples taken from the sludge batch, Sludge Batch 7b, being processed at the time of this testing. While both of the Optek units performed very reliably during this testing, there were statistically significant differences (although small on a practical scale) between the two units. Thus, testing should be conducted on any new unit of this Optek model to qualify it before it is used to support the DWPF operation.

  12. Evaluation Of A Turbidity Meter For Use At The Defense Waste Processing Facility

    SciTech Connect (OSTI)

    Mahannah, R. N.; Edwards, T. B.

    2013-01-15T23:59:59.000Z

    Savannah River Remediation's (SRR's) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a ''peanut'' vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 wt%. A ''go/no-go'' decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a ''go'' decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a ''no-go'' determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. A sludge simulant was used to develop standards for testing both Optek units and to determine the viability of a ''go/no-go'' CU response for each of the units. Statistical methods were used by SRNL to develop the critical CU value for the ''go/no-go'' decision for these standards for each Optek unit. Since only one sludge simulant was available for this testing, the sensitivity of these results to other simulants and to actual sludge material is not known. However, limited testing with samples from the actual DWPF process (both SRAT product samples and SMECT samples) demonstrated that the use of the ''go/no-go'' criteria developed from the sludge simulant testing was conservative for these samples taken from Sludge Batch 7b (SB7b), the sludge batch currently being processed. While both of the Optek units performed very reliably during this testing, there were statistically significant differences (although small on a practical scale) between the two units. Thus, testing should be conducted on any new unit of this Optek model to qualify it before it is used to support the DWPF operation.

  13. Cross-spectral study of the spatial relationships in the North Pacific sea-surface temperature anomaly field. Report No. 23

    SciTech Connect (OSTI)

    Middleton, J.W.

    1980-03-01T23:59:59.000Z

    Cross-spectral analysis is used to examine the dependence of the temporal covariation of sea-surface temperature (SST) anomalies at pairs of spatially separated points in the North Pacific on (1) the time scale of the variations, (2) the relative displacement of the points and (3) their location within the North Pacific basin. Spatial scales considered here range from 1000 kilometers up to the width of the basin. The study focuses on cross-spectral estimates for the interannual frequency band, 0.125-0.75 yr/sup -1/ although estimates for three other bands spanning higher frequencies are also examined.

  14. 1000 2000 3000 4000 .5 0 1 KILOMETER

    E-Print Network [OSTI]

    Kidd, William S. F.

    Rocks, Including Interbedded Limestone, Ordovician Black Shale/Slate Green Shale/Slate Bedded Limestone Quartz Arenite or Quartz Rich Wacke Brown/Tan/Olive DrabShale/Slate, Mudstone, and Sandstone Red Shale/Slate

  15. Topology of neutral hydrogen distribution with the Square Kilometer Array

    E-Print Network [OSTI]

    Wang, Yougang; Wu, Fengquan; Chen, Xuelei; Wang, Xin; Kim, Juhan; Park, Changbom; Lee, Khee-Gan; Cen, Renyue

    2015-01-01T23:59:59.000Z

    Morphology of the complex HI gas distribution can be quantified by statistics like the Minkowski functionals, and can provide a way to statistically study the large scale structure in the HI maps both at low redshifts, and during the epoch of reionization (EoR). At low redshifts, the 21cm emission traces the underlying matter distribution. Topology of the HI gas distribution, as measured by the genus, could be used as a "standard ruler". This enables the determination of distance-redshift relation and also the discrimination of various models of dark energy and of modified gravity. The topological analysis is also sensitive to certain primordial non-Gaussian features. Compared with two-point statistics, the topological statistics are more robust against the nonlinear gravitational evolution, bias, and redshift-space distortion. The HI intensity map observation naturally avoids the sparse sampling distortion, which is an important systematic in optical galaxy survey. The large cosmic volume accessible to SKA w...

  16. Evaluation of a portable x-ray fluorescence survey meter for the quantitative determination of trace metals in welding fumes

    E-Print Network [OSTI]

    Fehrenbacher, Mary Catherine

    1984-01-01T23:59:59.000Z

    Spectrometry Sensitivity Excitation Sources 12 16 Spectrometers and Detectors SHIELDED METAL ARC WELDING Health Effects of Welding THE PORTABLE X ? RAY FLUORESCENCE SURVEY METER METHODOLOGY RESULTS DISCUSSION OF RESULTS CAELUS I QblS RECQvfvt... Appendix C Basic Principle of AAS VITA Page 65 66 67 68 76 84 V1 11 LIST OF FIGURES Page 1. Transitions giving x-radiation 2. Fluorescent yield 3. Interaction of x-rays with matter 4. Particle size effects on x-ray intensity. . . 15 5...

  17. Tower Temperature and Humidity Sensors (TWR) Handbook

    SciTech Connect (OSTI)

    Cook, DR

    2010-02-01T23:59:59.000Z

    Three tall towers are installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility: a 60-meter triangular tower at the Southern Great Plains (SGP) Central Facility (CF), a 21-meter walkup scaffolding tower at the SGP Okmulgee forest site (E21), and a 40-meter triangular tower at the North Slope of Alaska (NSA) Barrow site. The towers are used for meteorological, radiological, and other measurements.

  18. Cooled, temperature controlled electrometer

    DOE Patents [OSTI]

    Morgan, John P. (Idaho Falls, ID)

    1992-01-01T23:59:59.000Z

    A cooled, temperature controlled electrometer for the measurement of small currents. The device employs a thermal transfer system to remove heat from the electrometer circuit and its environment and dissipate it to the external environment by means of a heat sink. The operation of the thermal transfer system is governed by a temperature regulation circuit which activates the thermal transfer system when the temperature of the electrometer circuit and its environment exceeds a level previously inputted to the external variable temperature control circuit. The variable temperature control circuit functions as subpart of the temperature control circuit. To provide temperature stability and uniformity, the electrometer circuit is enclosed by an insulated housing.

  19. Cooled, temperature controlled electrometer

    DOE Patents [OSTI]

    Morgan, John P.

    1992-08-04T23:59:59.000Z

    A cooled, temperature controlled electrometer for the measurement of small currents. The device employs a thermal transfer system to remove heat from the electrometer circuit and its environment and dissipate it to the external environment by means of a heat sink. The operation of the thermal transfer system is governed by a temperature regulation circuit which activates the thermal transfer system when the temperature of the electrometer circuit and its environment exceeds a level previously inputted to the external variable temperature control circuit. The variable temperature control circuit functions as subpart of the temperature control circuit. To provide temperature stability and uniformity, the electrometer circuit is enclosed by an insulated housing.

  20. Subsurface Temperature, Moisture, Thermal Conductivity and Heat Flux, Barrow, Area A, B, C, D

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Cable, William; Romanovsky, Vladimir

    Subsurface temperature data are being collected along a transect from the center of the polygon through the trough (and to the center of the adjacent polygon for Area D). Each transect has five 1.5m vertical array thermistor probes with 16 thermistors each. This dataset also includes soil pits that have been instrumented for temperature, water content, thermal conductivity, and heat flux at the permafrost table. Area C has a shallow borehole of 2.5 meters depth is instrumented in the center of the polygon.

  1. Strings at finite temperature

    SciTech Connect (OSTI)

    Arago C. de; Bazeia, D.; Eboli, O.J.P.; Marques, G.C.

    1985-12-15T23:59:59.000Z

    We obtain a semiclassical evaluation of the temperature for which the free energy of the strings of spontaneously broken scalar electrodynamics vanishes. We argue that, above this temperature, these objects should play a significant physical role.

  2. Analysis of PG&E`s residential end-use metered data to improve electricity demand forecasts

    SciTech Connect (OSTI)

    Eto, J.H.; Moezzi, M.M.

    1992-06-01T23:59:59.000Z

    It is generally acknowledged that improvements to end-use load shape and peak demand forecasts for electricity are limited primarily by the absence of reliable end-use data. In this report we analyze recent end-use metered data collected by the Pacific Gas and Electric Company from more than 700 residential customers to develop new inputs for the load shape and peak demand electricity forecasting models used by the Pacific Gas and Electric Company and the California Energy Commission. Hourly load shapes are normalized to facilitate separate accounting (by the models) of annual energy use and the distribution of that energy use over the hours of the day. Cooling electricity consumption by central air-conditioning is represented analytically as a function of climate. Limited analysis of annual energy use, including unit energy consumption (UEC), and of the allocation of energy use to seasons and system peak days, is also presented.

  3. Reliability of the LaCoste-Romberg Surface Ship Gravity Meter S-9 during cruise 60-H-13 of the Texas A. & M. Research Vessel "Hidalgo" 

    E-Print Network [OSTI]

    Chiburis, Edward Frank

    1962-01-01T23:59:59.000Z

    RELIABILITY OF THE LaCOSTE-ROMBERG SURFACE SH'IP GRAVITY METER S -9 DURING C R U I S E 60-8-13 0 F T H E T E R A S A. & M. R E S E . A R C 8 V E S S . E . L " HIDALGO " A Thesis By EDWARD F. CHIBURIS Submitted to the Graduate School... of the Agricultural and Mechanical College of Texas in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE January 1962 Major Sub)ect: Geophysics RELIABILITY OF THE LaCOSTE-ROMBERG SURFACE SHIP GRAVITY METERS-9 DURING C R U I S E 60-H...

  4. Radiation protection instrumentation - ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation part 2: high range beta and photon dose and dose rate portable instruments for emergency radiation protection purposes

    E-Print Network [OSTI]

    International Electrotechnical Commission. Geneva

    2007-01-01T23:59:59.000Z

    Radiation protection instrumentation - ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation

  5. Temperatures, heat flow, and water chemistry from drill holes in the Raft River geothermal system, Cassia County, Idaho

    SciTech Connect (OSTI)

    Nathenson, M.; Urban, T.C.; Diment, W.H.; Nehring, N.L.

    1980-01-01T23:59:59.000Z

    The Raft River area of Idaho contains a geothermal system of intermediate temperatures (approx. = 150/sup 0/C) at depths of about 1.5 km. Outside of the geothermal area, temperature measurements in three intermediate-depth drill holes (200 to 400 m) and one deep well (1500 m) indicate that the regional conductive heat flow is about 2.5 ..mu..cal/cm/sup 2/ sec or slightly higher and that temperature gradients range from 50/sup 0/ to 60/sup 0/C/km in the sediments, tuffs, and volcanic debris that fill the valley. Within and close to the geothermal system, temperature gradients in intermediate-depth drill holes (100 to 350 m) range from 120/sup 0/ to more than 600/sup 0/C/km, the latter value found close to an artesian hot well that was once a hot spring. Temperatures measured in three deep wells (1 to 2 km) within the geothermal area indicate that two wells are in or near an active upflow zone, whereas one well shows a temperature reversal. Assuming that the upflow is fault controlled, the flow is estimated to be 6 liter/sec per kilometer of fault length. From shut-in pressure data and the estimated flow, the permeability times thickness of the fault is calculated to be 2.4 darcy m. Chemical analyses of water samples from old flowing wells, recently completed intermediate-depth drill holes, and deep wells show a confused pattern. Geothermometer temperatures of shallow samples suggest significant re-equilibration at temperatures below those found in the deep wells. Silica geothermometer temperatures of water samples from the deep wells are in reasonable agreement with measured temperatures, whereas Na-K-Ca temperatures are significantly higher than measured temperatures. The chemical characteristics of the water, as indicated by chloride concentration, are extremely variable in shallow and deep samples. Chloride concentrations of the deep samples range from 580 to 2200 mg/kg.

  6. Temperature compensated photovoltaic array

    DOE Patents [OSTI]

    Mosher, D.M.

    1997-11-18T23:59:59.000Z

    A temperature compensated photovoltaic module comprises a series of solar cells having a thermally activated switch connected in parallel with several of the cells. The photovoltaic module is adapted to charge conventional batteries having a temperature coefficient differing from the temperature coefficient of the module. The calibration temperatures of the switches are chosen whereby the colder the ambient temperature for the module, the more switches that are on and form a closed circuit to short the associated solar cells. By shorting some of the solar cells as the ambient temperature decreases, the battery being charged by the module is not excessively overcharged at lower temperatures. PV module is an integrated solution that is reliable and inexpensive. 2 figs.

  7. Temperature compensated photovoltaic array

    DOE Patents [OSTI]

    Mosher, Dan Michael (Plano, TX)

    1997-11-18T23:59:59.000Z

    A temperature compensated photovoltaic module (20) comprised of a series of solar cells (22) having a thermally activated switch (24) connected in parallel with several of the cells (22). The photovoltaic module (20) is adapted to charge conventional batteries having a temperature coefficient (TC) differing from the temperature coefficient (TC) of the module (20). The calibration temperatures of the switches (24) are chosen whereby the colder the ambient temperature for the module (20), the more switches that are on and form a closed circuit to short the associated solar cells (22). By shorting some of the solar cells (22) as the ambient temperature decreases, the battery being charged by the module (20) is not excessively overcharged at lower temperatures. PV module (20) is an integrated solution that is reliable and inexpensive.

  8. The temperature market A stochastic model for temperature

    E-Print Network [OSTI]

    Pfeifer, Holger

    The temperature market A stochastic model for temperature Temperature futures Conclusions The Volatility of Temperature and Pricing of Weather Derivatives Fred Espen Benth Work in collaboration with J Universit¨at Ulm, April 2007 #12;The temperature market A stochastic model for temperature Temperature

  9. Ultrasonic liquid-level detector for varying temperature and pressure environments

    DOE Patents [OSTI]

    Anderson, R.L.; Miller, G.N.

    1981-10-26T23:59:59.000Z

    An ultrasonic liquid level detector for use in varying temperature and pressure environments, such as a pressurized water nuclear reactor vessel, is provided. The detector employs ultrasonic extensional and torsional waves launched in a multiplexed alternating sequence into a common sensor. The sensor is a rectangular cross section stainless steel rod which extends into the liquid medium whose level is to be detected. The sensor temperature derived from the extensional wave velocity measurements is used to compensate for the temperature dependence of the torsional wave velocity measurements which are also level dependent. The torsional wave velocity measurements of a multiple reflection sensor then provide a measurement of liquid level over a range of several meters with a small uncertainty over a temperature range of 20 to 250/sup 0/C and pressures up to 15 MPa.

  10. An Investigation of the Utilization of Smart Meter Data to Adapt Overcurrent Protection for Radial Distribution Systems with a High Penetration of Distributed Generation

    E-Print Network [OSTI]

    Douglin, Richard Henry

    2012-07-16T23:59:59.000Z

    . This thesis presents an investigation to adapt the pickup settings of the substation relay, based on configuration changes in a DS with DGs, using smart meter data from the prior year. An existing protection scheme causes the faulted areas of DSs with DGs...

  11. Instructions for Corning Model 220 pH Meter The electrode tip is a fragile glass bulb. Be careful or you will break it with a

    E-Print Network [OSTI]

    Cross, George

    Instructions for Corning Model 220 pH Meter The electrode tip is a fragile glass bulb. Be careful a polymer body electrode can create sufficient internal pressure to "explode" the glass bulb. When of cotton in the plastic electrode cover sleeve, add pH 7 buffer, and insert the electrode bulb

  12. Design for a GeV per meter, laser--driven electron accelerator Y.c. Huang, and R.L. Byer

    E-Print Network [OSTI]

    Byer, Robert L.

    optics, high power laser, laser-driven accelerator, ultra-fast laser, crossed-laser-beam acceleratorDesign for a GeV per meter, laser--driven electron accelerator Y.c. Huang, and R.L. Byer Stanford-based. multistaged, laser-driven electron linear accelerator microstructure operating in a vacuum that is capable

  13. An Evaluation of a Dual Coriolis Meter System for In-Line Monitoring of Suspended Solids Concentrations in Radioactive Slurries

    SciTech Connect (OSTI)

    Hylton, T.D.

    2000-09-01T23:59:59.000Z

    The U.S. Department of Energy (DOE) has millions of gallons of radioactive liquid and sludge wastes stored in underground tanks at several of its sites. In order to comply with various regulations and to circumvent potential problems associated with tank integrity, these wastes must be retrieved from the tanks, transferred to treatment facilities (or other storage locations), and processed to stable waste forms. The sludge wastes will typically be mobilized by some mechanical means (e.g., mixer pump, submerged jet) and mixed with the respective supernatants to create slurries that can be transferred by pipeline to the desired destination. Depending on the DOE site, these slurries may be transferred up to six miles. Since the wastes are radioactive, it is critically important for the transfers to be made without plugging a pipeline. To reduce such a risk, the relevant properties of the slurry (e.g., density, suspended solids concentration, viscosity, and particle size distribution) should be determined to be within acceptable limits prior to transfer. These properties should also be continuously monitored and controlled within specified limits while the transfer is in progress. The baseline method for determining the transport properties of slurries involves sampling and analysis; however, this method is time-consuming, and costly, and it does not provide real-time information. In addition, personnel who collect and analyze the samples are exposed to radiation. It is also questionable as to whether a laboratory analyst can obtain representative aliquots from the sample jar for these solid-liquid mixtures. The alternative method for determining the transport properties is in-line analysis. An in-line instrument is one that is connected to the process, analyzes the slurry as it flows through or by the instrument, and provides the results within seconds. This instrument can provide immediate feedback to operators so that, when necessary, the operators can respond quickly to counteract conditions that could lead to pipeline pluggage (e.g., backflushing the pipeline with water). One of the highest priorities is to determine the concentration of suspended solids in each of the slurries. In the project described in this report, two Coriolis meters were used simultaneously to create a suspended solids monitoring system that would provide accurate results with high precision. One Coriolis meter was used to measure the density of the slurry, while the other meter was used to measure the density of the carrier fluid (i.e., after filtration to remove the solid particles). The suspended solids concentration was then calculated from the density relationships between the slurry, the carrier fluid, and the dry solid particles. The latter density was determined by laboratory analysis and was assumed to be constant throughout the periods that grab samples were collected.

  14. A Miocene Island-Arc Volcanic Seamount- The Takashibiyama Formation...

    Open Energy Info (EERE)

    the vents, being flanked or covered with volcaniclastic flow deposits. Each volcanic pile is several kilometers wide and several hundred meters thick, and overlaps one after...

  15. Automatic temperature adjustment apparatus

    DOE Patents [OSTI]

    Chaplin, James E. (66 Overlook Rd., Bloomingdale, NJ 07403)

    1985-01-01T23:59:59.000Z

    An apparatus for increasing the efficiency of a conventional central space heating system is disclosed. The temperature of a fluid heating medium is adjusted based on a measurement of the external temperature, and a system parameter. The system parameter is periodically modified based on a closed loop process that monitors the operation of the heating system. This closed loop process provides a heating medium temperature value that is very near the optimum for energy efficiency.

  16. Low temperature cryoprobe

    DOE Patents [OSTI]

    Sungaila, Zenon F. (Orland Park, IL)

    1989-01-01T23:59:59.000Z

    A portable, hand held probe usable within a small confine to produce a point source of nitrogen or helium at a relatively constant temperature of 77 degrees Kelvin.

  17. Temperature and RH Targets

    Broader source: Energy.gov [DOE]

    Presented by Vishal O Mittal of the Florida Solar Energy Center at the High Temperature Membrane Working Group Meeting, San Francisco, September 14, 2006.

  18. The SNL100-03 Blade: Design Studies with Flatback Airfoils for the Sandia 100-meter Blade.

    SciTech Connect (OSTI)

    Griffith, Daniel; Richards, Phillip William

    2014-09-01T23:59:59.000Z

    A series of design studies were performed to inv estigate the effects of flatback airfoils on blade performance and weight for large blades using the Sandi a 100-meter blade designs as a starting point. As part of the study, the effects of varying the blade slenderness on blade structural performance was investigated. The advantages and disadvantages of blad e slenderness with respect to tip deflection, flap- wise & edge-wise fatigue resistance, panel buckling capacity, flutter speed, manufacturing labor content, blade total weight, and aerodynamic design load magn itude are quantified. Following these design studies, a final blade design (SNL100-03) was prod uced, which was based on a highly slender design using flatback airfoils. The SNL100-03 design with flatback airfoils has weight of 49 tons, which is about 16% decrease from its SNL100-02 predecessor that used conventional sharp trailing edge airfoils. Although not systematically optimized, the SNL100 -03 design study provides an assessment of and insight into the benefits of flatback airfoils for la rge blades as well as insights into the limits or negative consequences of high blade slenderness resulting from a highly slender SNL100-03 planform as was chosen in the final design definition. This docum ent also provides a description of the final SNL100-03 design definition and is intended to be a companion document to the distribution of the NuMAD blade model files for SNL100-03, which are made publicly available. A summary of the major findings of the Sandia 100-meter blade development program, from the initial SNL100-00 baseline blade through the fourth SNL100-03 blade study, is provided. This summary includes the major findings and outcomes of blade d esign studies, pathways to mitigate the identified large blade design drivers, and tool development that were produced over the course of this five-year research program. A summary of large blade tec hnology needs and research opportunities is also presented.

  19. Evaluation and enhancement of Texas ramp metering strategies, compliance, and alternative enforcement techniques: Go with the flow Houston. Public outreach plan (revised); Interim research report, September 1995--October 1996

    SciTech Connect (OSTI)

    Lancaster, S.; Fette, B.; Busler, L.; Miller, K.; Messer, C.

    1997-12-01T23:59:59.000Z

    This report describes the public outreach plan on the implementation of ramp meters along the Katy Freeway in Houston, Generally, ramp metering is neither beloved nor understood by the public. To gain public awareness, acceptance, compliance and continued support, ramp metering operations should be reinforced by a strong, ongoing public information and outreach campaign that communicates the need for and benefits of the program. Because the term `ramp metering` exhibits restrictions on the public, the phrase `Flow Signals` was developed to better describe the benefits of ramp metering; enhanced flow of traffic, fewer bottlenecks, and fewer trip delays. The logo, `Go with the Flow Houston,` and a graphic identity were developed to help communicate the theme throughout the various media where both the primary and secondary messages are intended to reach 15 different audiences. These media will include: a PSA, both static and changeable message signs, a brochure, Internet web site information, letters to specific audience and media relations efforts.

  20. Thermoelectric Temperature Control

    E-Print Network [OSTI]

    Saffman, Mark

    NOTE 201TM TECHNICAL Optimizing Thermoelectric Temperature Control Systems #12;2 May 1995 92-040000A © 1995 Wavelength Electronics, Inc. Thermoelectric coolers (TECs) are used in a variety understanding of thermal management techniques and carefully select the thermoelectric module, temperature

  1. Temperature-sensitive optrode

    DOE Patents [OSTI]

    Hirschfeld, T.B.

    1985-09-24T23:59:59.000Z

    Method and apparatus are provided for measuring temperature and for generating optical signals related to temperature. Light from a fiber optic is directed to a material whose fluorescent response varies with ambient temperature. The same fiber optic delivering the excitation beam also collects a portion of the fluorescent emission for analysis. Signal collection efficiency of the fiber optic is enhanced by requiring that the fluorescent probe material be in the shape of an oblong parabolically tapered solid. Reproducibility is enhanced by using Raman backscatter to monitor excitation beam fluctuations, and by using measurements of fluorescence lifetime. 10 figs.

  2. High Temperature Capacitor Development

    SciTech Connect (OSTI)

    John Kosek

    2009-06-30T23:59:59.000Z

    The absence of high-temperature electronics is an obstacle to the development of untapped energy resources (deep oil, gas and geothermal). US natural gas consumption is projected to grow from 22 trillion cubic feet per year (tcf) in 1999 to 34 tcf in 2020. Cumulatively this is 607 tcf of consumption by 2020, while recoverable reserves using current technology are 177 tcf. A significant portion of this shortfall may be met by tapping deep gas reservoirs. Tapping these reservoirs represents a significant technical challenge. At these depths, temperatures and pressures are very high and may require penetrating very hard rock. Logistics of supporting 6.1 km (20,000 ft) drill strings and the drilling processes are complex and expensive. At these depths up to 50% of the total drilling cost may be in the last 10% of the well depth. Thus, as wells go deeper it is increasingly important that drillers are able to monitor conditions down-hole such as temperature, pressure, heading, etc. Commercial off-the-shelf electronics are not specified to meet these operating conditions. This is due to problems associated with all aspects of the electronics including the resistors and capacitors. With respect to capacitors, increasing temperature often significantly changes capacitance because of the strong temperature dependence of the dielectric constant. Higher temperatures also affect the equivalent series resistance (ESR). High-temperature capacitors usually have low capacitance values because of these dielectric effects and because packages are kept small to prevent mechanical breakage caused by thermal stresses. Electrolytic capacitors do not operate at temperatures above 150oC due to dielectric breakdown. The development of high-temperature capacitors to be used in a high-pressure high-temperature (HPHT) drilling environment was investigated. These capacitors were based on a previously developed high-voltage hybridized capacitor developed at Giner, Inc. in conjunction with a unique high-temperature electrolyte developed during the course of the program. During this program the feasibility of operating a high voltage hybridized capacitor at 230oC was demonstrated. Capacitor specifications were established in conjunction with potential capacitor users. A method to allow for capacitor operation at both ambient and elevated temperatures was demonstrated. The program was terminated prior to moving into Phase II due to a lack of cost-sharing funds.

  3. Finite Temperature Effective Actions

    E-Print Network [OSTI]

    Ashok Das; J. Frenkel

    2009-08-27T23:59:59.000Z

    We present, from first principles, a direct method for evaluating the exact fermion propagator in the presence of a general background field at finite temperature, which can be used to determine the finite temperature effective action for the system. As applications, we determine the complete one loop finite temperature effective actions for 0+1 dimensional QED as well as the Schwinger model. These effective actions, which are derived in the real time (closed time path) formalism, generate systematically all the Feynman amplitudes calculated in thermal perturbation theory and also show that the retarded (advanced) amplitudes vanish in these theories.

  4. A Million Meter Milestone

    Broader source: Energy.gov [DOE]

    These devices are allowing Houston area residents to take personal control and ownership of her energy usage in a way not possible before.

  5. Propeller Flow Meter (Spanish) 

    E-Print Network [OSTI]

    Enciso, Juan; Santistevan, Dean; Hla, Aung K.

    2007-10-01T23:59:59.000Z

    -pies. Coloqueunpuntodecimaltresespa- ciosalaizquierda. Acre-pies=835.402 es multiplicada por el factor 0.01, mostrado en la car?tula del indicador. En la Figura 4b el caudal se mide en galones por minuto y el volumen total en acre-pulgadas cuando la lectura es multiplicada por el...

  6. Propeller Flow Meter (Spanish)

    E-Print Network [OSTI]

    Enciso, Juan; Santistevan, Dean; Hla, Aung K.

    2007-10-01T23:59:59.000Z

    -pies. Coloqueunpuntodecimaltresespa- ciosalaizquierda. Acre-pies=835.402 es multiplicada por el factor 0.01, mostrado en la car?tula del indicador. En la Figura 4b el caudal se mide en galones por minuto y el volumen total en acre-pulgadas cuando la lectura es multiplicada por el...

  7. Metered Visitor Motorcycle Pkg.

    E-Print Network [OSTI]

    North Carolina at Chapel Hill, University of

    acNIDER M EDICINE BER RYH ILL BR IN KH O U S- BU LLITT CHILLER BUILDING F KENAN STADIUM GEORGE WATTS HILL ALUMNI CENTER EHRINGHAUS FIELD DEPARTMENT OF PUBLIC SAFETY C AR PEN TRY SH O P CHILLER BUILDING NEURO SCIENCES WATER TOWER ITS MANNING CHILLER BUILDING PUBLIC SAFETY BLDG. MORRISON RIDGEROAD

  8. Western Meter Policy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    as Western) VAC Voltage Alternating Current VAR, Mvar Volt-Ampere-Reactive (Instantaneous Reactive Power), Mega-Var VDC Voltage Direct Current Western Area Power Administration...

  9. Low volume flow meter

    DOE Patents [OSTI]

    Meixler, Lewis D. (East Windsor, NJ)

    1993-01-01T23:59:59.000Z

    The low flow monitor provides a means for determining if a fluid flow meets a minimum threshold level of flow. The low flow monitor operates with a minimum of intrusion by the flow detection device into the flow. The electrical portion of the monitor is externally located with respect to the fluid stream which allows for repairs to the monitor without disrupting the flow. The electronics provide for the adjustment of the threshold level to meet the required conditions. The apparatus can be modified to provide an upper limit to the flow monitor by providing for a parallel electronic circuit which provides for a bracketing of the desired flow rate.

  10. Ultrasonic flow metering system

    DOE Patents [OSTI]

    Gomm, Tyler J. (Meridian, ID); Kraft, Nancy C. (Idaho Falls, ID); Mauseth, Jason A. (Pocatello, ID); Phelps, Larry D. (Pocatello, ID); Taylor, Steven C. (Idaho Falls, ID)

    2002-01-01T23:59:59.000Z

    A system for determining the density, flow velocity, and mass flow of a fluid comprising at least one sing-around circuit that determines the velocity of a signal in the fluid and that is correlatable to a database for the fluid. A system for determining flow velocity uses two of the inventive circuits with directional transmitters and receivers, one of which is set at an angle to the direction of flow that is different from the others.

  11. A microwave impedance meter

    E-Print Network [OSTI]

    Boaz, Virgil Layfaette

    1961-01-01T23:59:59.000Z

    Automatic Impedance Recorder for X-R d, " ~PIRE, V I. 42, 2 Pt. , I'Et, . Hewlett-Packard, "Operat ing Notes f' or IX'Iodel '. 5A 'lavegu I de F'hase Shifter, " Hewlett-Packard Co. , 275 Psd e Mi 1 I Road, Pale Alto, Cal ~ (Ilo date} Johnson, Welter C... the necessary equipment is not expensive. However, slotted-line measurements and impedance calculations are very time consuming and tedious. 1 ~ gaiter C. Johnson?T n Chapter 7, pp, lo5 1&!6, McGraw Hill Sock Company, inci ~ kew York, New York; 1...

  12. Lesson Plan: Power Metering

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(FactDepartment ofLetter Report:40PMDepartment ofs o u t h e aTheLesson 8 -Makes

  13. Metering | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(FactDepartment3311, 3312), OctoberMayEnergy MetalProgram Areas » Operations

  14. Meters Roads N Streams

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHighand Retrievals from aRodMIT-Harvard Center forMetallicH. Skinner,sc

  15. Metering | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking ofOil & GasTechnicalMeetingand NorthernMessaging

  16. High-Temperature Superconductivity

    ScienceCinema (OSTI)

    Peter Johnson

    2010-01-08T23:59:59.000Z

    Like astronomers tweaking images to gain a more detailed glimpse of distant stars, physicists at Brookhaven National Laboratory have found ways to sharpen images of the energy spectra in high-temperature superconductors ? materials that carry electrical c

  17. Penrose Well Temperatures

    SciTech Connect (OSTI)

    Christopherson, Karen

    2013-03-15T23:59:59.000Z

    Penrose Well Temperatures Geothermal waters have been encountered in several wells near Penrose in Fremont County, Colorado. Most of the wells were drilled for oil and gas exploration and, in a few cases, production. This ESRI point shapefile utilizes data from 95 wells in and around the Penrose area provided by the Colorado Oil and Gas Conservation Commission (COGCC) database at http://cogcc.state.co.us/ . Temperature data from the database were used to calculate a temperature gradient for each well. This information was then used to estimate temperatures at various depths. Projection: UTM Zone 13 NAD27 Extent: West -105.224871 East -105.027633 North 38.486269 South 38.259507 Originators: Colorado Oil and Gas Conservation Commission (COGCC) Karen Christopherson

  18. Low temperature cryoprobe

    DOE Patents [OSTI]

    Sungaila, Z.F.

    1988-04-12T23:59:59.000Z

    A portable, hand held probe usable within a small confine to produce a point source of nitrogen or helium at a relatively constant temperatures of 77 degrees Kelvin, is discussed. 3 figs.

  19. Temperature in the Throat

    E-Print Network [OSTI]

    Dariush Kaviani; Amir Esmaeil Mosaffa

    2015-03-06T23:59:59.000Z

    We study the temperature of extended objects in string theory. Rotating D-branes in warped Calabi-Yau throats have induced metrics with thermal horizons and Hawking temperatures a la Unruh effect. We solve the equations of motion for slow rotating probe branes and derive their induced metrics in the UV/IR solutions of warped conifold throats. Our analysis shows that horizons and temperatures of expected features form on the world volume of the rotating probe brane in terms of conserved charges in the UV solutions of the conifold throat. In certain limits, we find world volume horizons and temperatures of the form similar to those of rotating probes in the AdS throat.

  20. 1993 triggered lighnting test program: Environments within 20 meters of the lighting channel and small area temporary protection concepts

    SciTech Connect (OSTI)

    Fisher, R.J.; Schnetzer, G.H.

    1994-03-01T23:59:59.000Z

    Vertical electric fields, azimuthal magnetic fields, and earth step potentials at ground level have been measured at 10 and 20 meters from the base of triggered lightning flashes. For incident stroke peak currents in the range of 4.4 to 29 kA, vertical electric field change amplitudes as high as 210 kV/m were observed at 10 m, with rise times of the order of a few microseconds. Magnetic fields were found to follow Ampere`s law closely at both 10 and 20 m. Earth step potentials measured over a 0.5-m radial distance at the 10-m and 20m stations were linear with and had the same waveforms as the stroke currents. The step voltages exhibited a l/r distance dependence between the two measurement distances. A model that incorporates the presence of a thin surface layer, due to rain water saturation, of much higher conductivity than the bulk of the underlying earth is proposed to explain the observed behavior. Tests were also carried out to evaluate the effectiveness of several concepts for protecting a small exposed object, such as a piece of ordnance at the site of a transportation accident, from either a direct strike or from the indirect effects of electromagnetic fields produced by a nearby lightning flash to ground. Photographs of the occurrence of significant radial filamentary arcing along the surface of the ground from the strike points were acquired. This type of arcing, with a maximum radial extent of at least 20 m, was observed on six of seven of triggered flashes and on all strokes of 15-kA peak amplitude or higher.

  1. High temperature pressure gauge

    DOE Patents [OSTI]

    Echtler, J. Paul (Pittsburgh, PA); Scandrol, Roy O. (Library, PA)

    1981-01-01T23:59:59.000Z

    A high temperature pressure gauge comprising a pressure gauge positioned in fluid communication with one end of a conduit which has a diaphragm mounted in its other end. The conduit is filled with a low melting metal alloy above the diaphragm for a portion of its length with a high temperature fluid being positioned in the remaining length of the conduit and in the pressure gauge.

  2. Temperature measuring device

    DOE Patents [OSTI]

    Lauf, Robert J. (Oak Ridge, TN); Bible, Don W. (Clinton, TN); Sohns, Carl W. (Oak Ridge, TN)

    1999-01-01T23:59:59.000Z

    Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.

  3. 2007 OUTBURST OF 17P/HOLMES: THE ALBEDO AND THE TEMPERATURE OF THE DUST GRAINS

    SciTech Connect (OSTI)

    Ishiguro, Masateru; Watanabe, Jun-ichi; Fukushima, Hideo [National Astronomical Observatory, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Sarugaku, Yuki; Mito, Hiroyuki [Institute of Space and Astronautical Science, JAXA, 3-1-1, Yoshinodai, Chuo, Sagamihara, Kanagawa 252-5210 (Japan); Ootsubo, Takafumi [Graduate School of Science, Tohoku University, 6-3 Aramaki, Aoba-ku, Sendai 980-8578 (Japan); Kuroda, Daisuke; Yanagisawa, Kenshi [Okayama Astrophysical Observatory, NAOJ, 3037-5 Honjo, Kamogata, Asakuchi, Okayama 719-0232 (Japan); Honda, Mitsuhiko [Faculty of Science, Kanagawa University, 2946 Tsuchiya, Hiratsuka, Kanagawa 259-1293 (Japan); Miyata, Takashi [Institute of Astronomy, University of Tokyo, 2-21-1 Osawa, Mitaka, Tokyo 181-0015 (Japan); Niwa, Takahiro; Sakamoto, Makoto; Narusawa, Shin-ya [Nishi-Harima Astronomical Observatory, 407-2 Nishigaichi, Sayo, Hyogo 679-5313 (Japan); Akisawa, Hiroki, E-mail: ishiguro@astro.snu.ac.k [Himeji City Hoshinoko Yakata, Aoyama 1470-24, Himeji, Hyogo 671-2222 (Japan)

    2010-05-10T23:59:59.000Z

    Based on optical and infrared observations, we study the albedo and the temperature of the dust grains associated with the spectacular 2007 outburst of Jupiter-family comet 17P/Holmes. We found that the albedo at the solar phase angle {approx}16{sup 0} was 0.03-0.12. While the color temperature around 3-4 {mu}m was 360 {+-} 40 K, the color temperature at 12.4 {mu}m and 24.5 {mu}m was {approx}200 K, which is consistent with that of a blackbody. We studied the equilibrium temperature of the dust grains at 2.44 AU and found that the big discrepancy in the temperature was caused by the heterogeneity in particle size, that is, hotter components consist of submicron absorbing grains whereas colder components consist of large ({approx_gt}1 {mu}m) grains. The contemporaneous optical and mid-infrared observations suggest that the albedo and the temperature could decrease within {approx} 3 days after the outburst and stabilized at typical values of the other comets. We estimated the total mass injected into the coma by the outburst on the basis of the derived albedo and the optical magnitude for the entire dust cloud, and found that at least 4 x 10{sup 10} kg (equivalent to a few meter surface layer) was removed by the initial outburst event. The derived mass suggests that the outburst is explainable by neither the exogenetic asteroidal impact nor water ice sublimation driven by solar irradiation, but by an endogenic energy source. We conclude that the outburst was triggered by the energy sources several meters or more below the nuclear surface.

  4. Temperature initiated passive cooling system

    DOE Patents [OSTI]

    Forsberg, C.W.

    1994-11-01T23:59:59.000Z

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature. 1 fig.

  5. Temperature initiated passive cooling system

    DOE Patents [OSTI]

    Forsberg, Charles W. (Oak Ridge, TN)

    1994-01-01T23:59:59.000Z

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature.

  6. Temperature Data Evaluation

    SciTech Connect (OSTI)

    Gillespie, David

    2003-03-01T23:59:59.000Z

    Groundwater temperature is sensitive to the competing processes of heat flow from below the advective transport of heat by groundwater flow. Because groundwater temperature is sensitive to conductive and advective processes, groundwater temperature may be utilized as a tracer to further constrain the uncertainty of predictions of advective radionuclide transport models constructed for the Nevada Test Site (NTS). Since heat transport, geochemical, and hydrologic models for a given area must all be consistent, uncertainty can be reduced by devaluing the weight of those models that do not match estimated heat flow. The objective of this study was to identify the quantity and quality of available heat flow data at the NTS. One-hundred-forty-five temperature logs from 63 boreholes were examined. Thirteen were found to have temperature profiles suitable for the determination of heat flow values from one or more intervals within the boreholes. If sufficient spatially distributed heat flow values are obtained, a heat transport model coupled to a hydrologic model may be used to reduce the uncertainty of a nonisothermal hydrologic model of the NTS.

  7. High temperature thermometric phosphors

    DOE Patents [OSTI]

    Allison, Stephen W. (Knoxville, TN); Cates, Michael R. (Oak Ridge, TN); Boatner, Lynn A. (Oak Ridge, TN); Gillies, George T. (Earlysville, VA)

    1999-03-23T23:59:59.000Z

    A high temperature phosphor consists essentially of a material having the general formula LuPO.sub.4 :Dy.sub.(x),Eu.sub.y) wherein: 0.1 wt %.ltoreq.x.ltoreq.20 wt % and 0.1 wt %.ltoreq.y.ltoreq.20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopent. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions.

  8. High temperature thermometric phosphors

    DOE Patents [OSTI]

    Allison, S.W.; Cates, M.R.; Boatner, L.A.; Gillies, G.T.

    1999-03-23T23:59:59.000Z

    A high temperature phosphor consists essentially of a material having the general formula LuPO{sub 4}:Dy{sub x},Eu{sub y} wherein: 0.1 wt % {<=} x {<=} 20 wt % and 0.1 wt % {<=} y {<=} 20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopant. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions. 2 figs.

  9. High-temperature Pump Monitoring - High-temperature ESP Monitoring...

    Broader source: Energy.gov (indexed) [DOE]

    7 4.4.4 High-temperature Pump Monitoring - High-temperature ESP Monitoring Presentation Number: 018 Investigator: Dhruva, Brindesh (Schlumberger Technology Corp.) Objectives: To...

  10. Unaccounted-for gas project. Measurement Task Force (non-orifice meter studies). Volume 2A. Final report

    SciTech Connect (OSTI)

    Luttrell, D.J.; Noistering, R.H.; Peterson, J.D.; Cowgill, R.M.; Waller, R.L.

    1990-06-01T23:59:59.000Z

    The study was conducted to determine unaccounted-for (UAF) gas volumes resulting from operating Pacific Gas and Electric Co.'s transmission and distribution systems during 1987. The Measurement Task Force identified the amount of UAF attributable to measurement inaccuracies. Results show that the major residential measurement-related UAF elements, fixed-factor temperature and elevation/barometric pressure effects, contribute to UAF due to assumptions inherent in the billing calculation for average temperature and elevation which are then applied to all residential customers.

  11. High temperature adsorption measurements

    SciTech Connect (OSTI)

    Bertani, R.; Parisi, L.; Perini, R.; Tarquini, B.

    1996-01-24T23:59:59.000Z

    Adsorption phenomena are a rich and rather new field of study in geothermal research, in particular at very high temperature. ENEL is interested in the exploitation of geothermal regions with superheated steam, and it is important to understand the behavior of water-rock interaction. We have analyzed in the 170-200 °C temperature range four samples of Monteverdi cuttings; the next experimental effort will be at 220 °C and over in 1996. The first results of the 1995 runs are collected in this paper. We can highlight four main items: 1. At relative pressures over 0.6 the capillarity forces are very important. 2. There is no significant temperature effect. 3. Adsorbed water can be present, and it is able to multiply by a factor of 15 the estimated reserve of super-heated steam only. 4. Pores smaller than 15 Å do not contribute to the adsorbed mass.

  12. Temperature profile detector

    DOE Patents [OSTI]

    Tokarz, Richard D. (West Richland, WA)

    1983-01-01T23:59:59.000Z

    A temperature profile detector shown as a tubular enclosure surrounding an elongated electrical conductor having a plurality of meltable conductive segments surrounding it. Duplicative meltable segments are spaced apart from one another along the length of the enclosure. Electrical insulators surround these elements to confine molten material from the segments in bridging contact between the conductor and a second electrical conductor, which might be the confining tube. The location and rate of growth of the resulting short circuits between the two conductors can be monitored by measuring changes in electrical resistance between terminals at both ends of the two conductors. Additional conductors and separate sets of meltable segments operational at differing temperatures can be monitored simultaneously for measuring different temperature profiles.

  13. Temperature profile detector

    DOE Patents [OSTI]

    Tokarz, R.D.

    1983-10-11T23:59:59.000Z

    Disclosed is a temperature profile detector shown as a tubular enclosure surrounding an elongated electrical conductor having a plurality of meltable conductive segments surrounding it. Duplicative meltable segments are spaced apart from one another along the length of the enclosure. Electrical insulators surround these elements to confine molten material from the segments in bridging contact between the conductor and a second electrical conductor, which might be the confining tube. The location and rate of growth of the resulting short circuits between the two conductors can be monitored by measuring changes in electrical resistance between terminals at both ends of the two conductors. Additional conductors and separate sets of meltable segments operational at differing temperatures can be monitored simultaneously for measuring different temperature profiles. 8 figs.

  14. Temperature determination using pyrometry

    DOE Patents [OSTI]

    Breiland, William G. (Albuquerque, NM); Gurary, Alexander I. (Bridgewater, NJ); Boguslavskiy, Vadim (Princeton, NJ)

    2002-01-01T23:59:59.000Z

    A method for determining the temperature of a surface upon which a coating is grown using optical pyrometry by correcting Kirchhoff's law for errors in the emissivity or reflectance measurements associated with the growth of the coating and subsequent changes in the surface thermal emission and heat transfer characteristics. By a calibration process that can be carried out in situ in the chamber where the coating process occurs, an error calibration parameter can be determined that allows more precise determination of the temperature of the surface using optical pyrometry systems. The calibration process needs only to be carried out when the physical characteristics of the coating chamber change.

  15. Fluorescent temperature sensor

    DOE Patents [OSTI]

    Baker, Gary A [Los Alamos, NM; Baker, Sheila N [Los Alamos, NM; McCleskey, T Mark [Los Alamos, NM

    2009-03-03T23:59:59.000Z

    The present invention is a fluorescent temperature sensor or optical thermometer. The sensor includes a solution of 1,3-bis(1-pyrenyl)propane within a 1-butyl-1-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid solvent. The 1,3-bis(1-pyrenyl)propane remains unassociated when in the ground state while in solution. When subjected to UV light, an excited state is produced that exists in equilibrium with an excimer. The position of the equilibrium between the two excited states is temperature dependent.

  16. Transition temperature in QCD

    SciTech Connect (OSTI)

    Cheng, M.; Christ, N. H.; Mawhinney, R. D. [Physics Department, Columbia University, New York, New York 10027 (United States); Datta, S.; Jung, C.; Schmidt, C.; Umeda, T. [Physics Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Heide, J. van der; Kaczmarek, O.; Laermann, E.; Miao, C. [Fakultaet fuer Physik, Universitaet Bielefeld, D-33615 Bielefeld (Germany); Karsch, F. [Physics Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Fakultaet fuer Physik, Universitaet Bielefeld, D-33615 Bielefeld (Germany); Petreczky, P. [Physics Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); RIKEN-BNL Research Center, Brookhaven National Laboratory, Upton, New York 11973 (United States); Petrov, K. [Niels Bohr Institute, University of Copenhagen, Blegdamsvej 17, DK-2100 Copenhagen (Denmark)

    2006-09-01T23:59:59.000Z

    We present a detailed calculation of the transition temperature in QCD with two light and one heavier (strange) quark mass on lattices with temporal extent N{sub {tau}}=4 and 6. Calculations with improved staggered fermions have been performed for various light to strange quark mass ratios in the range, 0.05{<=}m-circumflex{sub l}/m-circumflex{sub s}{<=}0.5, and with a strange quark mass fixed close to its physical value. From a combined extrapolation to the chiral (m-circumflex{sub l}{yields}0) and continuum (aT{identical_to}1/N{sub {tau}}{yields}0) limits we find for the transition temperature at the physical point T{sub c}r{sub 0}=0.457(7) where the scale is set by the Sommer-scale parameter r{sub 0} defined as the distance in the static quark potential at which the slope takes on the value (dV{sub qq}(r)/dr){sub r=r{sub 0}}=1.65/r{sub 0}{sup 2}. Using the currently best known value for r{sub 0} this translates to a transition temperature T{sub c}=192(7)(4) MeV. The transition temperature in the chiral limit is about 3% smaller. We discuss current ambiguities in the determination of T{sub c} in physical units and also comment on the universal scaling behavior of thermodynamic quantities in the chiral limit.

  17. High temperature storage battery

    SciTech Connect (OSTI)

    Sammells, A.F.

    1988-06-07T23:59:59.000Z

    A high temperature electrochemical cell is described comprising: a solid-state divalent cation conducting electrolyte; a positive electrode in contact with the electrolyte; a solid-state negative electrode contacting a divalent cation conducting molten salt mediating agent providing ionic mediation between the solid-state negative electrode and the solid-state electrolyte.

  18. Low Temperature Performance Characterization

    Broader source: Energy.gov (indexed) [DOE]

    0.0036 0.0038 0.004 0.0042 Inverse Temperature, 1K Gen2 Electrodes and 1.2M LiPF6 in EC:EMC (3:7 ww) (BID 1935), 4.1V, 3 Sep. Gen2 Electrodes and 1.2M LiPF6 in EC:EMC (3:7 ww)...

  19. Localized temperature stability of low temperature cofired ceramics

    DOE Patents [OSTI]

    Dai, Steven Xunhu

    2013-11-26T23:59:59.000Z

    The present invention is directed to low temperature cofired ceramic modules having localized temperature stability by incorporating temperature coefficient of resonant frequency compensating materials locally into a multilayer LTCC module. Chemical interactions can be minimized and physical compatibility between the compensating materials and the host LTCC dielectrics can be achieved. The invention enables embedded resonators with nearly temperature-independent resonance frequency.

  20. Temperature Temperature is the physical property of a

    E-Print Network [OSTI]

    Alexeenko, Alina

    Temperature Temperature is the physical property of a system which underlines the common notion and said to be at the same temperature. If a thermometer is placed in a gas container then the thermal zero. #12;Temperature The energy exchange between gas and thermometer is through collisions of gas

  1. High Temperature Membrane Working Group

    Broader source: Energy.gov [DOE]

    This presentation provides an overview of the High Temperature Membrane Working Group Meeting in May 2007.

  2. Method and apparatus for correcting eddy current signal voltage for temperature effects

    DOE Patents [OSTI]

    Kustra, Thomas A. (N. Huntingdon, PA); Caffarel, Alfred J. (Pittsburgh, PA)

    1990-01-01T23:59:59.000Z

    An apparatus and method for measuring physical characteristics of an electrically conductive material by the use of eddy-current techniques and compensating measurement errors caused by changes in temperature includes a switching arrangement connected between primary and reference coils of an eddy-current probe which allows the probe to be selectively connected between an eddy current output oscilloscope and a digital ohm-meter for measuring the resistances of the primary and reference coils substantially at the time of eddy current measurement. In this way, changes in resistance due to temperature effects can be completely taken into account in determining the true error in the eddy current measurement. The true error can consequently be converted into an equivalent eddy current measurement correction.

  3. Engine Cylinder Temperature Control

    DOE Patents [OSTI]

    Kilkenny, Jonathan Patrick (Peoria, IL); Duffy, Kevin Patrick (Metamora, IL)

    2005-09-27T23:59:59.000Z

    A method and apparatus for controlling a temperature in a combustion cylinder in an internal combustion engine. The cylinder is fluidly connected to an intake manifold and an exhaust manifold. The method and apparatus includes increasing a back pressure associated with the exhaust manifold to a level sufficient to maintain a desired quantity of residual exhaust gas in the cylinder, and varying operation of an intake valve located between the intake manifold and the cylinder to an open duration sufficient to maintain a desired quantity of fresh air from the intake manifold to the cylinder, wherein controlling the quantities of residual exhaust gas and fresh air are performed to maintain the temperature in the cylinder at a desired level.

  4. Case Study of the Failure of two 13.8kV Control & Metering Transformers that caused significant Equipment Damage

    SciTech Connect (OSTI)

    Dreifuerst, G R; Chew, D B; Mangonon, H L; Swyers, P W

    2011-08-25T23:59:59.000Z

    The degradation and failure of cast-coil epoxy windings within 13.8kV control power transformers and metering potential transformers has been shown to be dangerous to both equipment and personnel, even though best industrial design practices were followed. Accident scenes will be examined for two events at a U.S. Department of Energy laboratory. Failure modes will be explained and current design practices discussed with changes suggested to prevent a recurrence and to minimize future risk. New maintenance philosophies utilizing partial discharge testing of the transformers as a prediction of end-of-life will be examined.

  5. Thermionic Converter Temperature Controller

    SciTech Connect (OSTI)

    Shaner,B. J.; Wolf, Joseph H.; Johnson, Robert G. R.

    1999-08-23T23:59:59.000Z

    A method and apparatus for controlling the temperature of a thermionic reactor over a wide range of operating power, including a thermionic reactor having a plurality of integral cesium reservoirs, a honeycomb material disposed about the reactor which has a plurality of separated cavities, a solid sheath disposed about the honeycomb material and having an opening therein communicating with the honeycomb material and cavities thereof, and a shell disposed about the sheath for creating a coolant annulus therewith so that the coolant in the annulus may fill the cavities and permit nucleate boiling during the operation of the reactor.

  6. Thermionic converter temperature controller

    DOE Patents [OSTI]

    Shaner, Benjamin J. (McMurray, PA); Wolf, Joseph H. (Pittsburgh, PA); Johnson, Robert G. R. (Trafford, PA)

    2001-04-24T23:59:59.000Z

    A method and apparatus for controlling the temperature of a thermionic reactor over a wide range of operating power, including a thermionic reactor having a plurality of integral cesium reservoirs, a honeycomb material disposed about the reactor which has a plurality of separated cavities, a solid sheath disposed about the honeycomb material and having an opening therein communicating with the honeycomb material and cavities thereof, and a shell disposed about the sheath for creating a coolant annulus therewith so that the coolant in the annulus may fill the cavities and permit nucleate boiling during the operation of the reactor.

  7. Drexel University Temperature Sensors

    SciTech Connect (OSTI)

    K. L. Davis; D. L. Knudson; J. L. Rempe; B. M. Chase

    2014-09-01T23:59:59.000Z

    This document summarizes background information and presents results related to temperature measurements in the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) Drexel University Project 31091 irradiation. The objective of this test was to assess the radiation performance of new ceramic materials for advanced reactor applications. Accordingly, irradiations of transition metal carbides and nitrides were performed using the Hydraulic Shuttle Irradiation System (HSIS) in the B-7 position and in static capsules inserted into the A-3 and East Flux Trap Position 5 locations of the ATR.

  8. ARM - Word Seek: Temperature

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadapInactiveVisiting the TWP TWP Related Links Facilities and InstrumentsInstrumentsTemperature

  9. Temperature | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro Industries PvtStratosolar Jump to:HoldingsTechint Spa JumpTVCEtTemperature" Showing 9

  10. Temperature Maps and Data

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal StocksProvedFeet)ThousandNumber andCrudeTemperature Maps and Data

  11. Temperature Maps and Data

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal StocksProvedFeet)ThousandNumber andCrudeTemperature Maps and

  12. Net Metering Policy Development and Distributed Solar Generation in Minnesota: Overview of Trends in Nationwide Policy Development and Implications of Increasing the Eligible System Size Cap

    SciTech Connect (OSTI)

    Doris, E.; Busche, S.; Hockett, S.

    2009-12-01T23:59:59.000Z

    The goal of the Minnesota net metering policy is to give the maximum possible encouragement to distributed generation assets, especially solar electric systems (MN 2008). However, according to a published set of best practices (NNEC 2008) that prioritize the maximum development of solar markets within states, the Minnesota policy does not incorporate many of the important best practices that may help other states transform their solar energy markets and increase the amount of grid-connected distributed solar generation assets. Reasons cited include the low system size limit of 40kW (the best practices document recommends a 2 MW limit) and a lack of language protecting generators from additional utility fees. This study was conducted to compare Minnesota's policies to national best practices. It provides an overview of the current Minnesota policy in the context of these best practices and other jurisdictions' net metering policies, as well as a qualitative assessment of the impacts of raising the system size cap within the policy based on the experiences of other states.

  13. Customer-Economics of Residential Photovoltaic Systems: The Impact of High Renewable Energy Penetrations on Electricity Bill Savings with Net Metering

    Broader source: Energy.gov [DOE]

    Residential photovoltaic (PV) systems in the US are often compensated at the customer's underlying retail electricity rate through net metering. There is growing interest in understanding how potential changes in rates may impact the value of bill savings from PV. This article uses a production cost and capacity expansion model to project California hourly wholesale electricity market prices under a reference scenario and a 33% renewables scenario. Second, based on the wholesale electricity market prices generated by the model, the article develops retail rates (i.e., flat, time-of-use, and real-time pricing) for each future scenario based on standard retail rate design principles. Finally, based on these retail rates, the bill savings from PV are estimated for 226 California residential customers under two types of net metering, for each scenario. The article finds that high renewable penetrations can drive substantial changes in residential retail rates and that these changes, together with variations in retail rate structures and PV compensation mechanisms, interact to place substantial uncertainty on the future value of bill savings from residential PV.

  14. Areas of Anomalous Surface Temperature in Garfield County, Colorado, as Identified from ASTER Thermal Data

    SciTech Connect (OSTI)

    Hussein, Khalid

    2012-02-01T23:59:59.000Z

    Citation Information: Originator: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Publication Date: 2012 Title: Very Warm Modeled Temperature Garfield Edition: First Publication Information: Publication Place: Earth Science & Observation Center, Cooperative Institute for Research in Environmental Science (CIRES), University of Colorado, Boulder Publisher: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Description: This layer contains areas of anomalous surface temperature in Garfield County identified from ASTER thermal data and spatial based insolation model. The temperature is calculated using the Emissivity Normalization Algorithm that separate temperature from emissivity. The incoming solar radiation was calculated using spatial based insolation model developed by Fu and Rich (1999). Then the temperature due to solar radiation was calculated using emissivity derived from ASTER data. The residual temperature, i.e. temperature due to solar radiation subtracted from ASTER temperature was used to identify thermally anomalous areas. Areas that had temperature greater than 2? were considered ASTER modeled very warm surface exposures (thermal anomalies) Spatial Domain: Extent: Top: 4441550.552290 m Left: 271445.053363 m Right: 359825.053363 m Bottom: 4312490.552290 m Contact Information: Contact Organization: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Contact Person: Khalid Hussein Address: CIRES, Ekeley Building Earth Science & Observation Center (ESOC) 216 UCB City: Boulder State: CO Postal Code: 80309-0216 Country: USA Contact Telephone: 303-492-6782 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGS’1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System ’1984 (WGS ’1984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

  15. Areas of Anomalous Surface Temperature in Routt County, Colorado, as Identified from ASTER Thermal Data

    SciTech Connect (OSTI)

    Hussein, Khalid

    2012-02-01T23:59:59.000Z

    Citation Information: Originator: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Publication Date: 2012 Title: Very Warm Modeled Temperature Routt Edition: First Publication Information: Publication Place: Earth Science & Observation Center, Cooperative Institute for Research in Environmental Science (CIRES), University of Colorado, Boulder Publisher: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Description: This layer contains areas of anomalous surface temperature in Routt County identified from ASTER thermal data and spatial based insolation model. The temperature is calculated using the Emissivity Normalization Algorithm that separate temperature from emissivity. The incoming solar radiation was calculated using spatial based insolation model developed by Fu and Rich (1999). Then the temperature due to solar radiation was calculated using emissivity derived from ASTER data. The residual temperature, i.e. temperature due to solar radiation subtracted from ASTER temperature was used to identify thermally anomalous areas. Areas that had temperature greater than 2? were considered ASTER modeled very warm surface exposures (thermal anomalies) Spatial Domain: Extent: Top: 4501071.574000 m Left: 311351.975000 m Right: 359681.975000 m Bottom: 4447251.574000 m Contact Information: Contact Organization: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Contact Person: Khalid Hussein Address: CIRES, Ekeley Building Earth Science & Observation Center (ESOC) 216 UCB City: Boulder State: CO Postal Code: 80309-0216 Country: USA Contact Telephone: 303-492-6782 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGS’1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System ’1984 (WGS ’1984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

  16. Areas of Anomalous Surface Temperature in Chaffee County, Colorado, as Identified from ASTER Thermal Data

    SciTech Connect (OSTI)

    Hussein, Khalid

    2012-02-01T23:59:59.000Z

    Citation Information: Originator: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Publication Date: 2012 Title: Very Warm Modeled Temperature Chaffee Edition: First Publication Information: Publication Place: Earth Science & Observation Center, Cooperative Institute for Research in Environmental Science (CIRES), University of Colorado, Boulder Publisher: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Description: This layer contains areas of anomalous surface temperature in Chaffee County identified from ASTER thermal data and spatial based insolation model. The temperature is calculated using the Emissivity Normalization Algorithm that separate temperature from emissivity. The incoming solar radiation was calculated using spatial based insolation model developed by Fu and Rich (1999). Then the temperature due to solar radiation was calculated using emissivity derived from ASTER data. The residual temperature, i.e. temperature due to solar radiation subtracted from ASTER temperature was used to identify thermally anomalous areas. Areas that had temperature greater than 2? were considered ASTER modeled very warm surface exposures (thermal anomalies) Spatial Domain: Extent: Top: 4333432.368072 m Left: 366907.700763 m Right: 452457.816015 m Bottom: 4208271.566715 m Contact Information: Contact Organization: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Contact Person: Khalid Hussein Address: CIRES, Ekeley Building Earth Science & Observation Center (ESOC) 216 UCB City: Boulder State: CO Postal Code: 80309-0216 Country: USA Contact Telephone: 303-492-6782 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGS’1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System ’1984 (WGS ’1984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

  17. Areas of Anomalous Surface Temperature in Archuleta County, Colorado, as Identified from ASTER Thermal Data

    SciTech Connect (OSTI)

    Hussein, Khalid

    2012-02-01T23:59:59.000Z

    Citation Information: Originator: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Publication Date: 2012 Title: Very Warm Modeled Temperature Archuleta Edition: First Publication Information: Publication Place: Earth Science & Observation Center, Cooperative Institute for Research in Environmental Science (CIRES), University of Colorado, Boulder Publisher: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Description: This layer contains areas of anomalous surface temperature in Archuleta County identified from ASTER thermal data and spatial based insolation model. The temperature is calculated using the Emissivity Normalization Algorithm that separate temperature from emissivity. The incoming solar radiation was calculated using spatial based insolation model developed by Fu and Rich (1999). Then the temperature due to solar radiation was calculated using emissivity derived from ASTER data. The residual temperature, i.e. temperature due to solar radiation subtracted from ASTER temperature was used to identify thermally anomalous areas. Areas that had temperature greater than 2? were considered ASTER modeled very warm surface exposures (thermal anomalies) Spatial Domain: Extent: Top: 4144691.792023 m Left: 285531.662851 m Right: 348694.182686 m Bottom: 4097005.210304 m Contact Information: Contact Organization: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Contact Person: Khalid Hussein Address: CIRES, Ekeley Building Earth Science & Observation Center (ESOC) 216 UCB City: Boulder State: CO Postal Code: 80309-0216 Country: USA Contact Telephone: 303-492-6782 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGS’1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System ’1984 (WGS ’1984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

  18. Areas of Anomalous Surface Temperature in Dolored County, Colorado, as Identified from ASTER Thermal Data

    SciTech Connect (OSTI)

    Hussein, Khalid

    2012-02-01T23:59:59.000Z

    Citation Information: Originator: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Publication Date: 2012 Title: Very Warm Modeled Temperature Dolores Edition: First Publication Information: Publication Place: Earth Science & Observation Center, Cooperative Institute for Research in Environmental Science (CIRES), University of Colorado, Boulder Publisher: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Description: This layer contains areas of anomalous surface temperature in Dolores County identified from ASTER thermal data and spatial based insolation model. The temperature is calculated using the Emissivity Normalization Algorithm that separate temperature from emissivity. The incoming solar radiation was calculated using spatial based insolation model developed by Fu and Rich (1999). Then the temperature due to solar radiation was calculated using emissivity derived from ASTER data. The residual temperature, i.e. temperature due to solar radiation subtracted from ASTER temperature was used to identify thermally anomalous areas. Areas that had temperature greater than 2? were considered ASTER modeled very warm surface exposures (thermal anomalies) Spatial Domain: Extent: Top: 4186234.213315 m Left: 212558.673056 m Right: 232922.811862 m Bottom: 4176781.467043 m Contact Information: Contact Organization: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Contact Person: Khalid Hussein Address: CIRES, Ekeley Building Earth Science & Observation Center (ESOC) 216 UCB City: Boulder State: CO Postal Code: 80309-0216 Country: USA Contact Telephone: 303-492-6782 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGS’1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System ’1984 (WGS ’1984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

  19. The Greenhouse Effect Temperature Equilibrium

    E-Print Network [OSTI]

    Walter, Frederick M.

    The Greenhouse Effect #12;Temperature Equilibrium The Earth is in equilibrium with the Sun temperature is about 14C, or 287K. The 40K difference is due to the greenhouse effect. Essentially all

  20. Philosophy 26 High Temperature Superconductivity

    E-Print Network [OSTI]

    Callender, Craig

    Philosophy 26 High Temperature Superconductivity By Ohm's Law, resistance will dim. Low temperature superconductivity was discovered in 1911 by Heike was explained by BCS theory. BCS theory explains superconductivity microscopically

  1. Design, performance, and cost characteristics of high temperature superconducting magnetic energy storage

    SciTech Connect (OSTI)

    Schoenung, S.M.; Meier, W.R. (W.J. Schafer Associates, Inc., Pleasanton, CA (United States)); Fagaly, R.L.; Heiberger, M.; Stephens, R.B.; Leuer, J.A.; Guzman, R.A. (General Atomics, San Diego, CA (United States))

    1993-03-01T23:59:59.000Z

    A conceptual design for superconducting magnetic energy storage (SMES) using oxide superconductors with higher critical temperature than metallic superconductors has been analyzed for design features, refrigeration requirements, and estimated costs of major components. The study covered the energy storage range from 2 to 200 MWh at power levels from 4 to 400 MW. A SMES that uses high temperature superconductors (HTS) and operates at high magnetic field (e.g., 10 tesla), can be more compact than a comparable, conventional low-temperature device at lower field. The refrigeration power required for a higher temperature unit (20 to 77 Kelvin) will be less by 60 to 90 percent. The improvement in energy efficiency is significant for small units, but less important for large ones. The material cost for HTS units is dominated by the cost of superconductor, so that the total cost of an HTS system will be comparable to a low temperature system only if the superconductor price in $/Ampere-meter is made comparable by increasing current density or decreasing wire cost.

  2. Hot Pot Contoured Temperature Gradient Map

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Lane, Michael

    Temperature gradient contours derived from Oski temperature gradient hole program and from earlier published information.

  3. Hot Pot Contoured Temperature Gradient Map

    SciTech Connect (OSTI)

    Lane, Michael

    2013-06-28T23:59:59.000Z

    Temperature gradient contours derived from Oski temperature gradient hole program and from earlier published information.

  4. Battery system with temperature sensors

    DOE Patents [OSTI]

    Wood, Steven J.; Trester, Dale B.

    2012-11-13T23:59:59.000Z

    A battery system to monitor temperature includes at least one cell with a temperature sensing device proximate the at least one cell. The battery system also includes a flexible member that holds the temperature sensor proximate to the at least one cell.

  5. High temperature interfacial superconductivity

    DOE Patents [OSTI]

    Bozovic, Ivan (Mount Sinai, NY); Logvenov, Gennady (Port Jefferson Station, NY); Gozar, Adrian Mihai (Port Jefferson, NY)

    2012-06-19T23:59:59.000Z

    High-temperature superconductivity confined to nanometer-scale interfaces has been a long standing goal because of potential applications in electronic devices. The spontaneous formation of a superconducting interface in bilayers consisting of an insulator (La.sub.2CuO.sub.4) and a metal (La.sub.1-xSr.sub.xCuO.sub.4), neither of which is superconducting per se, is described. Depending upon the layering sequence of the bilayers, T.sub.c may be either .about.15 K or .about.30 K. This highly robust phenomenon is confined to within 2-3 nm around the interface. After exposing the bilayer to ozone, T.sub.c exceeds 50 K and this enhanced superconductivity is also shown to originate from a 1 to 2 unit cell thick interfacial layer. The results demonstrate that engineering artificial heterostructures provides a novel, unconventional way to fabricate stable, quasi two-dimensional high T.sub.c phases and to significantly enhance superconducting properties in other superconductors. The superconducting interface may be implemented, for example, in SIS tunnel junctions or a SuFET.

  6. Measurement of thermodynamic temperature of high temperature fixed points

    SciTech Connect (OSTI)

    Gavrilov, V. R.; Khlevnoy, B. B.; Otryaskin, D. A.; Grigorieva, I. A.; Samoylov, M. L.; Sapritsky, V. I. [All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), 46 Ozernaya St., Moscow 119361 (Russian Federation)] [All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), 46 Ozernaya St., Moscow 119361 (Russian Federation)

    2013-09-11T23:59:59.000Z

    The paper is devoted to VNIIOFI's measurements of thermodynamic temperature of the high temperature fixed points Co-C, Pt-C and Re-C within the scope of the international project coordinated by the Consultative Committee for Thermometry working group 5 'Radiation Thermometry'. The melting temperatures of the fixed points were measured by a radiance mode radiation thermometer calibrated against a filter radiometer with known irradiance spectral responsivity via a high temperature black body. This paper describes the facility used for the measurements, the results and estimated uncertainties.

  7. The aqueous chemistry of aluminum: A new approach to high temperature solubility measurements

    SciTech Connect (OSTI)

    Palmer, Donald A.; Wesolowski, David J.; Benezeth, Pascale

    1996-01-24T23:59:59.000Z

    The solubility of boehmite, AlO(OH), has been measured as a function of pH (2 - 10, depending on ionic strength), temperature (100 - 250°C) and ionic strength (0.03 - 1 molal, NaCl) in a hydrogen-electrode concentration cell, HECC, which provided in situ measurement of hydrogen ion molality. Samples of the solution were withdrawn after the pH reading stabilized for analysis of total aluminum content by ion chromatography. Acidic or basic titrant could then be metered into the cell to affect a change in the pH of the solution. The direction of approach to the equilibrium saturated state could be readily varied to ensure that the system was reversible thermodynamically. This represents our second application of direct pH measurement to high temperature solubility studies. The results at low ionic strength are compared with those from two recently-reported high-temperature studies of boehmite solubility, which relied on the conventional batch technique. Comparisons are also made with the low temperature (<90°C) hydrolysis constants for aluminum garnered from solubility measurements with gibbsite as the stable phase. Based on these preliminary results, it is possible to draw some general conclusions concerning the relative importance of the aluminum species in solution and to reduce significantly the number of experiments needed to define this complex system in a thermodynamic sense.

  8. The aqueous chemistry of aluminum: A new approach to high temperature solubility measurements

    SciTech Connect (OSTI)

    Palmer, D.A.; Wesolowski, D.J.; Benezeth, P.

    1996-01-01T23:59:59.000Z

    The solubility of boehmite, AlO(OH), has been measured as a function of pH (2-10, depending on ionic strength) temperature (100- 250{degrees}C) and ionic strength (0.03-1 molal, NaCl) in a hydrogen- electrode concentration cell, HECC, which provided in situ measurement of hydrogen ion molality. Samples of the solution were withdrawn after the pH reading stabilized for analysis of total aluminum content by ion chromatography. Acidic or basic titrant could then be metered into the cell to affect a change in the pH of the solution. The direction of approach to the equilibrium saturated state could be readily varied to ensure that the system was reversible thermodynamically. This represents our second application of direct pH measurement to high temperature solubility studies. The results as low ionic strength are compared with those from two recently-reported high-temperature studies of boehmite solubility, which relied on the conventional batch technique. Comparisons are also made with the low temperature (<90{degrees}C) hydrolysis constants for aluminum garnered from solubility measurements with gibbsite as the stable phase. Based on these preliminary results, it is possible to draw some general conclusions concerning the relative importance of the aluminum species in solution and to reduce significantly the number of experiments needed to define this complex system in a thermodynamic sense.

  9. High-temperature ceramic receivers

    SciTech Connect (OSTI)

    Jarvinen, P. O.

    1980-01-01T23:59:59.000Z

    An advanced ceramic dome cavity receiver is discussed which heats pressurized gas to temperatures above 1800/sup 0/F (1000/sup 0/C) for use in solar Brayton power systems of the dispersed receiver/dish or central receiver type. Optical, heat transfer, structural, and ceramic material design aspects of the receiver are reported and the development and experimental demonstration of a high-temperature seal between the pressurized gas and the high-temperature silicon carbide dome material is described.

  10. RECHARGEABLE HIGH-TEMPERATURE BATTERIES

    E-Print Network [OSTI]

    Cairns, Elton J.

    2014-01-01T23:59:59.000Z

    F. Eshman, High-Performance Batteries for Electric-VehicleS. Sudar, High Performance Batteries for Electric-VehicleHIGH-TEMPERATURE BATTERIES Elton J. Cairns January 1981 TWO-

  11. Hotline IV ?High Temperature ESP

    Broader source: Energy.gov (indexed) [DOE]

    Hotline IV - High Temperature ESP Brindesh Dhruva (principal Inv.) Michael Dowling (presenter) Schlumberger Track Name May 18, 2010 This presentation does not contain any...

  12. Low Temperature Material Bonding Technique

    DOE Patents [OSTI]

    Ramsey, J. Michael (Knoxville, TN); Foote, Robert S. (Oak Ridge, TN)

    2000-10-10T23:59:59.000Z

    A method of performing a lower temperature bonding technique to bond together two mating pieces of glass includes applying a sodium silicate aqueous solution between the two pieces.

  13. Low temperature material bonding technique

    DOE Patents [OSTI]

    Ramsey, J. Michael (Knoxville, TN); Foote, Robert S. (Oak Ridge, TN)

    2002-02-12T23:59:59.000Z

    A method of performing a lower temperature bonding technique to bond together two mating pieces of glass includes applying a sodium silicate aqueous solution between the two pieces.

  14. Pretest Caluculations of Temperature Changes for Field Thermal Conductivity Tests

    SciTech Connect (OSTI)

    N.S. Brodsky

    2002-07-17T23:59:59.000Z

    A large volume fraction of the potential monitored geologic repository at Yucca Mountain may reside in the Tptpll (Tertiary, Paintbrush Group, Topopah Spring Tuff, crystal poor, lower lithophysal) lithostratigraphic unit. This unit is characterized by voids, or lithophysae, which range in size from centimeters to meters. A series of thermal conductivity field tests are planned in the Enhanced Characterization of the Repository Block (ECRB) Cross Drift. The objective of the pretest calculation described in this document is to predict changes in temperatures in the surrounding rock for these tests for a given heater power and a set of thermal transport properties. The calculation can be extended, as described in this document, to obtain thermal conductivity, thermal capacitance (density x heat capacity, J {center_dot} m{sup -3} {center_dot} K{sup -1}), and thermal diffusivity from the field data. The work has been conducted under the ''Technical Work Plan For: Testing and Monitoring'' (BSC 2001). One of the outcomes of this analysis is to determine the initial output of the heater. This heater output must be sufficiently high that it will provide results in a reasonably short period of time (within several weeks or a month) and be sufficiently high that the heat increase is detectable by the instruments employed in the test. The test will be conducted in stages and heater output will be step increased as the test progresses. If the initial temperature is set too high, the experiment will not have as many steps and thus fewer thermal conductivity data points will result.

  15. The effect of bed temperature on oxygen partial pressures in an atmospheric fluidized bed combustor

    SciTech Connect (OSTI)

    Malik, S.R. [PCSIR, Karachi (Pakistan). Fuel Research Centre; Gibbs, B.M. [Univ. of Leeds (United Kingdom). Dept. of Fuel and Energy

    1996-12-31T23:59:59.000Z

    One of the factors which cause corrosion of in-bed material is the existence of low oxygen levels. Therefore, oxygen`s partial pressure measurements are important for corrosion studies in atmospheric fluidized bed combustor (AFBC). The effect of bed temperature on oxygen levels has been discussed in this paper. The experiments were conducted on a 0.3 meters square combustor. In-bed oxygen partial pressures were measured using zirconia oxygen probes and recorded on a computerized data logging system. Detail statistical analysis of the data has been presented. The probability density function (PDF) was the most important statistical parameter which reveals not only how long environment is exposed to oxidizing reducing conditions but also the probability whether corrosion could occur.

  16. Low temperature irradiation tests on

    E-Print Network [OSTI]

    McDonald, Kirk

    Sample cool down by He gas loop 10K ­ 20K Fast neutron flux Measured by Ni activation in 2010 1.4xK #12;reactor Cryogenics #12;Al-Cu-Mg He gas temperature near sample 12K Resistance changesLow temperature irradiation tests on stabilizer materials using reactor neutrons at KUR Makoto

  17. Q: When planning a wind farm, how are wind resources estimated? And if the average wind speed is known at 10 meters is there a general rule for estimating the wind speed at

    E-Print Network [OSTI]

    Q: When planning a wind farm, how are wind resources estimated? And if the average wind speed is known at 10 meters is there a general rule for estimating the wind speed at larger heights above ground level? The wind resource at a wind farm can be estimated in two ways: by measurement or by modeling

  18. Detecting temperature fluctuations at equilibrium

    E-Print Network [OSTI]

    Dixit, Purushottam D

    2015-01-01T23:59:59.000Z

    Gibbs and Boltzmann definitions of temperature agree only in the macroscopic limit. The ambiguity in identifying the equilibrium temperature of a finite sized `small' system exchanging energy with a bath is usually understood as a limitation of conventional statistical mechanics. We interpret this ambiguity as resulting from a stochastically fluctuating temperature coupled with the phase space variables giving rise to a broad temperature distribution. With this ansatz, we develop the equilibrium statistics and dynamics of small systems. Numerical evidence using an analytically tractable model shows that the effects of temperature fluctuations can be detected in equilibrium and dynamical properties of the phase space of the small system. Our theory generalizes statistical mechanics to small systems relevant to biophysics and nanotechnology.

  19. Research Initiative Will Demonstrate Low Temperature Geothermal...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Research Initiative Will Demonstrate Low Temperature Geothermal Electrical Power Generation Systems Using Oilfield Fluids Research Initiative Will Demonstrate Low Temperature...

  20. Low-to-moderate temperature geothermal resource assessment for Nevada, area specific studies. Final report, June 1, 1980-August 30, 1981

    SciTech Connect (OSTI)

    Trexler, D.T.; Koenig, B.A.; Flynn, T.; Bruce, J.L.; Ghusn, G. Jr.

    1981-01-01T23:59:59.000Z

    The Hawthorne study area is located in Mineral County, Nevada and surrounds the municipality of the same name. It encompasses an area of approximately 310 sq. km (120 sq. mi), and most of the land belongs to the US Army Ammunition Plant. The energy needs of the military combined with those of the area population (over 5,000 residents) are substantial. The area is classified as having a high potential for direct applications using the evaluation scheme described in Texler and others (1979). A variety of scientific techniques was employed during area-wide resource assessment. General geologic studies demonstrate the lithologic diversity in the area; these studies also indicate possible sources for dissolved fluid constituents. Geophysical investigations include aero-magnetic and gravity surveys which aid in defining the nature of regional, and to a lesser extent, local variations in subsurface configurations. Surface and near-surface structural features are determined using various types of photo imagery including low sun-angle photography. An extensive shallow depth temperature probe survey indicates two zones of elevated temperature on opposite sides of the Walker Lake basin. Temperature-depth profiles from several wells in the study area indicate significant thermal fluid-bearing aquifers. Fluid chemical studies suggest a wide spatial distribution for the resource, and also suggest a meteoric recharge source in the Wassuk Range. Finally, a soil-mercury survey was not a useful technique in this study area. Two test holes were drilled to conclude the area resource assessment, and thermal fluids were encountered in both wells. The western well has measured temperatures as high as 90 C (194 F) within 150 meters (500 ft) of the surface. Temperature profiles in this well indicate a negative temperature gradient below 180 meters (590 ft). The eastern hole had a bottom hole temperature of 61 C (142 F) at a depth of only 120 meters (395 ft). A positive gradient is observed to a total depth in the well. Several conclusions are drawn from this study: the resource is distributed over a relatively large area; resource fluid temperatures can exceed 90 C (194 F), but are probably limited to a maximum of 125 C (257 F); recharge to the thermal system is meteoric, and flow of the fluids in the near surface (< 500 m) is not controlled by faults; heat supplied to the system may be related to a zone of partially melted crustal rocks in the area 25 km (15 mi) south of Hawthorne. Four papers and an introduction are included. A separate abstract was prepared for each paper. (MHR)

  1. The effect of initial temperature on flame acceleration and deflagration-to-detonation transition phenomenon

    SciTech Connect (OSTI)

    Ciccarelli, G.; Boccio, J.L.; Ginsberg, T.; Finfrock, C.; Gerlach, L. [Brookhaven National Lab., Upton, NY (United States); Tagawa, H. [Nuclear Power Engineering Corp., Tokyo (Japan); Malliakos, A. [Nuclear Regulatory Commission, Washington, DC (United States)

    1998-05-01T23:59:59.000Z

    The High-Temperature Combustion Facility at BNL was used to conduct deflagration-to-detonation transition (DDT) experiments. Periodic orifice plates were installed inside the entire length of the detonation tube in order to promote flame acceleration. The orifice plates are 27.3-cm-outer diameter, which is equivalent to the inner diameter of the tube, and 20.6-cm-inner diameter. The detonation tube length is 21.3-meters long, and the spacing of the orifice plates is one tube diameter. A standard automobile diesel engine glow plug was used to ignite the test mixture at one end of the tube. Hydrogen-air-steam mixtures were tested at a range of temperatures up to 650K and at an initial pressure of 0.1 MPa. In most cases, the limiting hydrogen mole fraction which resulted in DDT corresponded to the mixture whose detonation cell size, {lambda}, was equal to the inner diameter of the orifice plate, d (e.g., d/{lambda}=1). The only exception was in the dry hydrogen-air mixtures at 650K where the DDT limit was observed to be 11 percent hydrogen, corresponding to a value of d/{lambda} equal to 5.5. For a 10.5 percent hydrogen mixture at 650K, the flame accelerated to a maximum velocity of about 120 mIs and then decelerated to below 2 mIs. By maintaining the first 6.1 meters of the vessel at the ignition end at 400K, and the rest of the vessel at 650K, the DDT limit was reduced to 9.5 percent hydrogen (d/{lambda}=4.2). This observation indicates that the d/{lambda}=1 DDT limit criteria provides a necessary condition but not a sufficient one for the onset of DDT in obstacle laden ducts. In this particular case, the mixture initial condition (i.e., temperature) resulted in the inability of the mixture to sustain flame acceleration to the point where DDT could occur. It was also observed that the distance required for the flame to accelerate to the point of detonation initiation, referred to as the run-up distance, was found to be a function of both the hydrogen mole fraction and the mixture initial temperature. Decreasing the hydrogen mole fraction or increasing the initial mixture temperature resulted in longer run-up distances. The density ratio across the flame and the speed of sound in the unburned mixture were found to be two parameters which influence the run-up distance.

  2. Effect of Gas Turbine Exhaust Temperature, Stack Temperature and Ambient Temperature on Overall Efficiency of Combine Cycle Power Plant

    E-Print Network [OSTI]

    unknown authors

    Abstract—The gas turbine exhaust temperature, stack temperature and ambient temperature play a very important role during the predication of the performance of combine cycle power plant. This paper covers parametric analysis of effects of gas turbine exhaust temperature, stack temperature and ambient temperature on the overall efficiency of combine cycle power plant keeping the gas turbine efficiency as well as steam turbine efficiency constant. The results shows that out of three variables i.e. turbine exhaust temperature, stack temperature and ambient temperature, the most dominating factor of increasing the overall efficiency of the combine cycle power plant is the stack temperature.

  3. Method for measuring surface temperature

    DOE Patents [OSTI]

    Baker, Gary A. (Los Alamos, NM); Baker, Sheila N. (Los Alamos, NM); McCleskey, T. Mark (Los Alamos, NM)

    2009-07-28T23:59:59.000Z

    The present invention relates to a method for measuring a surface temperature using is a fluorescent temperature sensor or optical thermometer. The sensor includes a solution of 1,3-bis(1-pyrenyl)propane within a 1-butyl-1-1-methyl pyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid solvent. The 1,3-bis(1-pyrenyl)propane remains unassociated when in the ground state while in solution. When subjected to UV light, an excited state is produced that exists in equilibrium with an excimer. The position of the equilibrium between the two excited states is temperature dependent.

  4. Shock temperature measurements in ammonia

    SciTech Connect (OSTI)

    Radousky, H.B.; Mitchell, A.C.; Nellis, W.J.; Ross, M.

    1985-07-01T23:59:59.000Z

    Our first shock temperature measurements on a cryogenic target are reported for NH/sub 3/. A new fast optical pyrometer and a cryogenic specimen holder for liquid NH/sub 3/ were developed to measure shock temperatures of 4400 and 3600 K at pressures of 61 and 48 GPa. These conditions correspond to those in the ice layers in Uranus and Neptune. The shock temperature data are in reasonable agreement with an equation of state based on an intermolecular potential derived from NH/sub 3/ Hugoniot data.

  5. Areas of Anomalous Surface Temperature in Alamosa and Saguache Counties, Colorado, as Identified from ASTER Thermal Data

    SciTech Connect (OSTI)

    Hussein, Khalid

    2012-02-01T23:59:59.000Z

    Citation Information: Originator: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Publication Date: 2012 Title: Very Warm Modeled Temperature Alamosa Saguache Edition: First Publication Information: Publication Place: Earth Science & Observation Center, Cooperative Institute for Research in Environmental Science (CIRES), University of Colorado, Boulder Publisher: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Description: This layer contains areas of anomalous surface temperature in Alamosa and Saguache Counties identified from ASTER thermal data and spatial based insolation model. The temperature is calculated using the Emissivity Normalization Algorithm that separate temperature from emissivity. The incoming solar radiation was calculated using spatial based insolation model developed by Fu and Rich (1999). Then the temperature due to solar radiation was calculated using emissivity derived from ASTER data. The residual temperature, i.e. temperature due to solar radiation subtracted from ASTER temperature was used to identify thermally anomalous areas. Areas that had temperature greater than 2? were considered ASTER modeled very warm surface exposures (thermal anomalies) Spatial Domain: Extent: Top: 4217727.601630 m Left: 394390.400264 m Right: 460179.841813 m Bottom: 4156258.036086 m Contact Information: Contact Organization: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Contact Person: Khalid Hussein Address: CIRES, Ekeley Building Earth Science & Observation Center (ESOC) 216 UCB City: Boulder State: CO Postal Code: 80309-0216 Country: USA Contact Telephone: 303-492-6782 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGS’1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System ’1984 (WGS ’1984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

  6. Optimizing Low Temperature Diesel Combustion

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Diesel Consortium 2008 DOE Merit Review - UW-ERC 1 Optimizing Low Temperature Diesel Combustion Profs. Rolf Reitz, P. Farrell, D. Foster, J. Ghandhi, C. Rutland, S. Sanders Engine...

  7. High temperature structural insulating material

    DOE Patents [OSTI]

    Chen, W.Y.

    1984-07-27T23:59:59.000Z

    A high temperature structural insulating material useful as a liner for cylinders of high temperature engines through the favorable combination of high service temperature (above about 800/sup 0/C), low thermal conductivity (below about 0.2 W/m/sup 0/C), and high compressive strength (above about 250 psi). The insulating material is produced by selecting hollow ceramic beads with a softening temperature above about 800/sup 0/C, a diameter within the range of 20-200 ..mu..m, and a wall thickness in the range of about 2 to 4 ..mu..m; compacting the beads and a compatible silicate binder composition under pressure and sintering conditions to provide the desired structural form with the structure having a closed-cell, compact array of bonded beads.

  8. High temperature structural insulating material

    DOE Patents [OSTI]

    Chen, Wayne Y. (Munster, IN)

    1987-01-01T23:59:59.000Z

    A high temperature structural insulating material useful as a liner for cylinders of high temperature engines through the favorable combination of high service temperature (above about 800.degree. C.), low thermal conductivity (below about 0.2 W/m.degree. C.), and high compressive strength (above about 250 psi). The insulating material is produced by selecting hollow ceramic beads with a softening temperature above about 800.degree. C., a diameter within the range of 20-200 .mu.m, and a wall thickness in the range of about 2-4 .mu.m; compacting the beads and a compatible silicate binder composition under pressure and sintering conditions to provide the desired structural form with the structure having a closed-cell, compact array of bonded beads.

  9. Fuel Temperature Coefficient of Reactivity

    SciTech Connect (OSTI)

    Loewe, W.E.

    2001-07-31T23:59:59.000Z

    A method for measuring the fuel temperature coefficient of reactivity in a heterogeneous nuclear reactor is presented. The method, which is used during normal operation, requires that calibrated control rods be oscillated in a special way at a high reactor power level. The value of the fuel temperature coefficient of reactivity is found from the measured flux responses to these oscillations. Application of the method in a Savannah River reactor charged with natural uranium is discussed.

  10. Low to moderate temperature nanolaminate heater

    DOE Patents [OSTI]

    Eckels, J. Del (Livermore, CA); Nunes, Peter J. (Danville, CA); Simpson, Randall L. (Livermore, CA); Hau-Riege, Stefan (Fremont, CA); Walton, Chris (Oakland, CA); Carter, J. Chance (Livermore, CA); Reynolds, John G. (San Ramon, CA)

    2011-01-11T23:59:59.000Z

    A low to moderate temperature heat source comprising a high temperature energy source modified to output low to moderate temperatures wherein the high temperature energy source modified to output low to moderate temperatures is positioned between two thin pieces to form a close contact sheath. In one embodiment the high temperature energy source modified to output low to moderate temperatures is a nanolaminate multilayer foil of reactive materials that produces a heating level of less than 200.degree. C.

  11. Advanced Metering - Using advanced Metering to Improve Building...

    Broader source: Energy.gov (indexed) [DOE]

    * Tenant Perspective- Impact their needs have on Energy Bottomline - ie Computer RoomsData Centers OT Utility Requests Office of Facilities Management & Services Programs 56...

  12. High temperature thermometric phosphors for use in a temperature sensor

    DOE Patents [OSTI]

    Allison, Stephen W. (Knoxville, TN); Cates, Michael R. (Oak Ridge, TN); Boatner, Lynn A. (Oak Ridge, TN); Gillies, George T. (Earlysville, VA)

    1998-01-01T23:59:59.000Z

    A high temperature phosphor consists essentially of a material having the general formula LuPO.sub.4 :Dy.sub.(x),Eu.sub.(y), wherein: 0.1 wt %.ltoreq.x.ltoreq.20 wt % and 0.1 wt %.ltoreq.y.ltoreq.20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopent. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions.

  13. High temperature thermometric phosphors for use in a temperature sensor

    DOE Patents [OSTI]

    Allison, S.W.; Cates, M.R.; Boatner, L.A.; Gillies, G.T.

    1998-03-24T23:59:59.000Z

    A high temperature phosphor consists essentially of a material having the general formula LuPO{sub 4}:Dy{sub (x)},Eu{sub (y)}, wherein: 0.1 wt %{<=}x{<=}20 wt % and 0.1 wt %{<=}y{<=}20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopant. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions. 2 figs.

  14. Apparatus and method for high temperature viscosity and temperature measurements

    DOE Patents [OSTI]

    Balasubramaniam, Krishnan (Mississippi State, MS); Shah, Vimal (Houston, TX); Costley, R. Daniel (Mississippi State, MS); Singh, Jagdish P. (Mississippi State, MS)

    2001-01-01T23:59:59.000Z

    A probe for measuring the viscosity and/or temperature of high temperature liquids, such as molten metals, glass and similar materials comprises a rod which is an acoustical waveguide through which a transducer emits an ultrasonic signal through one end of the probe, and which is reflected from (a) a notch or slit or an interface between two materials of the probe and (b) from the other end of the probe which is in contact with the hot liquid or hot melt, and is detected by the same transducer at the signal emission end. To avoid the harmful effects of introducing a thermally conductive heat sink into the melt, the probe is made of relatively thermally insulative (non-heat-conductive) refractory material. The time between signal emission and reflection, and the amplitude of reflections, are compared against calibration curves to obtain temperature and viscosity values.

  15. THE TEMPERATURES OF RED SUPERGIANTS

    SciTech Connect (OSTI)

    Davies, Ben [Astrophysics Research Institute, Liverpool John Moores University, Egerton Wharf, Birkenhead CH41 1LD (United Kingdom)] [Astrophysics Research Institute, Liverpool John Moores University, Egerton Wharf, Birkenhead CH41 1LD (United Kingdom); Kudritzki, Rolf-Peter; Gazak, Zach [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States)] [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States); Plez, Bertrand [Laboratoire Univers et Particules de Montpellier, Universite Montpellier 2, CNRS, F-34095 Montpellier (France)] [Laboratoire Univers et Particules de Montpellier, Universite Montpellier 2, CNRS, F-34095 Montpellier (France); Trager, Scott [Kapteyn Institute, University of Groningen, P.O. Box 800, 9700-AV Groningen (Netherlands)] [Kapteyn Institute, University of Groningen, P.O. Box 800, 9700-AV Groningen (Netherlands); Lancon, Ariane [Observatoire Astronomique and CNRS UMR 7550, Universite de Strasbourg, F-67000 Strasbourg (France)] [Observatoire Astronomique and CNRS UMR 7550, Universite de Strasbourg, F-67000 Strasbourg (France); Bergemann, Maria [Max-Planck-Institute for Astrophysics, Karl-Schwarzschild-Str. 1, D-85741 Garching (Germany)] [Max-Planck-Institute for Astrophysics, Karl-Schwarzschild-Str. 1, D-85741 Garching (Germany); Evans, Chris [UK Astronomy Technology Centre, Royal Observatory Edinburgh, Blackford Hill, Edinburgh EH9 3HJ (United Kingdom)] [UK Astronomy Technology Centre, Royal Observatory Edinburgh, Blackford Hill, Edinburgh EH9 3HJ (United Kingdom); Chiavassa, Andrea [CNRS Laboratoire Lagrange, Universite de Nice Sophia-Antipolis, Observatoire de la Cote d'Azur, BP 4229, F-06304 Nice Cedex 4 (France)] [CNRS Laboratoire Lagrange, Universite de Nice Sophia-Antipolis, Observatoire de la Cote d'Azur, BP 4229, F-06304 Nice Cedex 4 (France)

    2013-04-10T23:59:59.000Z

    We present a re-appraisal of the temperatures of red supergiants (RSGs) using their optical and near-infrared spectral energy distributions (SEDs). We have obtained data of a sample of RSGs in the Magellanic Clouds using VLT+XSHOOTER, and we fit MARCS model atmospheres to different regions of the spectra, deriving effective temperatures for each star from (1) the TiO bands, (2) line-free continuum regions of the SEDs, and (3) the integrated fluxes. We show that the temperatures derived from fits to the TiO bands are systematically lower than the other two methods by several hundred kelvin. The TiO fits also dramatically overpredict the flux in the near-IR, and imply extinctions which are anomalously low compared to neighboring stars. In contrast, the SED temperatures provide good fits to the fluxes at all wavelengths other than the TiO bands, are in agreement with the temperatures from the flux integration method, and imply extinctions consistent with nearby stars. After considering a number of ways to reconcile this discrepancy, we conclude that three-dimensional effects (i.e., granulation) are the most likely cause, as they affect the temperature structure in the upper layers where the TiO lines form. The continuum, however, which forms at much deeper layers, is apparently more robust to such effects. We therefore conclude that RSG temperatures are much warmer than previously thought. We discuss the implications of this result for stellar evolution and supernova progenitors, and provide relations to determine the bolometric luminosities of RSGs from single-band photometry.

  16. Thermal disconnect for high-temperature batteries

    DOE Patents [OSTI]

    Jungst, Rudolph George (Albuquerque, NM); Armijo, James Rudolph (Albuquerque, NM); Frear, Darrel Richard (Austin, TX)

    2000-01-01T23:59:59.000Z

    A new type of high temperature thermal disconnect has been developed to protect electrical and mechanical equipment from damage caused by operation at extreme temperatures. These thermal disconnects allow continuous operation at temperatures ranging from 250.degree. C. to 450.degree. C., while rapidly terminating operation at temperatures 50.degree. C. to 150.degree. C. higher than the continuous operating temperature.

  17. Temperature & Nuclear Fusion 4 October 2011

    E-Print Network [OSTI]

    Militzer, Burkhard

    Temperature & Nuclear Fusion 4 October 2011 Goals · Review temperature in stars · Practice using the important energy scales for nuclear fusion Temperature 1. For each relation we regularly use in class temperature. #12;temperature & nuclear fusion 2 Nuclear Fusion 2. There are a few different energy scales

  18. The influence of initial temperature on flame acceleration and deflagration-to-detonation transition

    SciTech Connect (OSTI)

    Ciccarelli, G.; Boccio, J.L.; Ginsberg, T. [and others

    1996-07-01T23:59:59.000Z

    The influence of initial mixture temperature on deflagration-to-detonation transition (DDT) has been investigated experimentally. The experiments were carried out in a 27-cm-inner diameter, 21.3-meter-long heated detonation tube, which was equipped with periodic orifice plates to promote flame acceleration. Hydrogen-air-steam mixtures were tested at a range of temperatures up to 650K and at an initial pressure of 0.1 MPa. In most cases, the limiting hydrogen mole fraction which resulted in transition to detonation corresponded to the mixture whose detonation cell size, {lambda}, was approximately equal to the inner diameter of the orifice plate, d (e.g., d/{lambda}{approximately}1). The only exception was in dry hydrogen-air mixtures at 650K where the DDT limit was observed to be 11 percent hydrogen, corresponding to a value of d/{lambda} equal to 5.5. For a 10.5 percent hydrogen mixture at 650K, the flame accelerated to a maximum velocity of about 120 m/s and then decelerated to below 2 m/s. This observation indicates that the d/{lambda} = 1 DDT limit criterion provides a necessary condition but not a sufficient one for the onset of DDT in obstacle-laden ducts. In this particular case, the mixture initial condition (i.e., temperature) resulted in the inability of the mixture to sustain flame acceleration to the point where DDT could occur. It was also observed that the distance required for the flame to accelerate to the onset of detonation was a function of both the hydrogen mole fraction and the mixture initial temperature. For example, decreasing the hydrogen mole fraction or increasing the initial mixture temperature resulted in longer transition distances.

  19. Peak demand reduction from pre-cooling with zone temperature reset in an office building

    SciTech Connect (OSTI)

    Xu, Peng; Haves, Philip; Piette, Mary Ann; Braun, James

    2004-08-01T23:59:59.000Z

    The objective of this study was to demonstrate the potential for reducing peak-period electrical demand in moderate-weight commercial buildings by modifying the control of the HVAC system. An 80,000 ft{sup 2} office building with a medium-weight building structure and high window-to-wall ratio was used for a case study in which zone temperature set-points were adjusted prior to and during occupancy. HVAC performance data and zone temperatures were recorded using the building control system. Additional operative temperature sensors for selected zones and power meters for the chillers and the AHU fans were installed for the study. An energy performance baseline was constructed from data collected during normal operation. Two strategies for demand shifting using the building thermal mass were then programmed in the control system and implemented progressively over a period of one month. It was found that a simple demand limiting strategy performed well in this building. This strategy involved maintaining zone temperatures at the lower end of the comfort region during the occupied period up until 2 pm. Starting at 2 pm, the zone temperatures were allowed to float to the high end of the comfort region. With this strategy, the chiller power was reduced by 80-100% (1-2.3 W/ft{sup 2}) during normal peak hours from 2-5 pm, without causing any thermal comfort complaints. The effects on the demand from 2-5 pm of the inclusion of pre-cooling prior to occupancy are unclear.

  20. Peak Demand Reduction from Pre-Cooling with Zone Temperature Reset in an Office Building

    SciTech Connect (OSTI)

    Xu, Peng; Haves, Philip; Piette, Mary Ann; Braun, James

    2006-08-01T23:59:59.000Z

    The objective of this study was to demonstrate the potential for reducing peak-period electrical demand in moderate-weight commercial buildings by modifying the control of the HVAC system. An 80,000 ft{sup 2} office building with a medium-weight building structure and high window-to-wall ratio was used for a case study in which zone temperature set-points were adjusted prior to and during occupancy. HVAC performance data and zone temperatures were recorded using the building control system. Additional operative temperature sensors for selected zones and power meters for the chillers and the AHU fans were installed for the study. An energy performance baseline was constructed from data collected during normal operation. Two strategies for demand shifting using the building thermal mass were then programmed in the control system and implemented progressively over a period of one month. It was found that a simple demand limiting strategy performed well in this building. This strategy involved maintaining zone temperatures at the lower end of the comfort region during the occupied period up until 2 pm. Starting at 2 pm, the zone temperatures were allowed to float to the high end of the comfort region. With this strategy, the chiller power was reduced by 80-100% (1-2.3 W/ft{sup 2}) during normal peak hours from 2-5 pm, without causing any thermal comfort complaints. The effects on the demand from 2-5 pm of the inclusion of pre-cooling prior to occupancy are unclear.