Powered by Deep Web Technologies
Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

American Samoa- Net Metering  

Broader source: Energy.gov [DOE]

The American Samoa Power Authority (ASPA), a government-owned electric utility, is the only power provider in this U.S. territory of almost 70,000 people. ASPA's "Interconnection and Net Energy...

2

Geothermal energy for American Samoa  

SciTech Connect (OSTI)

The geothermal commercialization potential in American Samoa was investigated. With geothermal energy harnessed in American Samoa, a myriad of possibilities would arise. Existing residential and business consumers would benefit from reduced electricity costs. The tuna canneries, demanding about 76% of the island's process heat requirements, may be able to use process heat from a geothermal source. Potential new industries include health spas, aquaculture, wood products, large domestic and transhipment refrigerated warehouses, electric cars, ocean nodule processing, and a hydrogen economy. There are no territorial statutory laws of American Samoa claiming or reserving any special rights (including mineral rights) to the territorial government, or other interests adverse to a land owner, for subsurface content of real property. Technically, an investigation has revealed that American Samoa does possess a geological environment conducive to geothermal energy development. Further studies and test holes are warranted.

Not Available

1980-03-01T23:59:59.000Z

3

American Samoa Power Authority | Open Energy Information  

Open Energy Info (EERE)

Samoa Power Authority Samoa Power Authority Jump to: navigation, search Name American Samoa Power Authority Place American Samoa Utility Id 40429 Utility Location Yes Ownership S NERC Location AS Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Distribution Yes Activity Retail Marketing Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=American_Samoa_Power_Authority&oldid=408977"

4

American Samoa: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

inlineLabel":"","visitedicon":"" Country Profile Name American Samoa Population 55,519 GDP Unavailable Energy Consumption 0.01 Quadrillion Btu 2-letter ISO code AS 3-letter ISO...

5

American Samoa Recovery Act State Memo | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

American Samoa Recovery Act State Memo American Samoa Recovery Act State Memo American Samoa Recovery Act State Memo The American Recovery & Reinvestment Act (ARRA) is making a meaningful down payment on the nation's energy and environmental future. The Recovery Act investments in American Samoa are supporting a broad range of clean energy projects, from energy efficiency and the smart grid to solar power and biofuels. Through these investments, American Samoa's businesses, universities, non-profits, and local governments are creating quality jobs today and positioning American Samoa to play an important role in the new energy economy of the future. American Samoa Recovery Act State Memo More Documents & Publications AMERICAN SAMOA RECOVERY ACT SNAPSHOT Guam Recovery Act State Memo State Energy Efficient Appliance Rebate Program (SEEARP) American Recovery

6

Recovery Act State Memos American Samoa  

Broader source: Energy.gov (indexed) [DOE]

American American Samoa For questions about DOE's Recovery Act activities, please contact the DOE Recovery Act Clearinghouse: 1-888-DOE-RCVY (888-363-7289), Monday through Friday, 9 a.m. to 7 p.m. Eastern Time https://recoveryclearinghouse.energy.gov/contactUs.htm. All numbers and projects listed as of June 1, 2010 TABLE OF CONTENTS RECOVERY ACT SNAPSHOT................................................................................... 1 FUNDING ALLOCATION TABLE.............................................................................. 2 ENERGY EFFICIENCY ................................................................................................ 1 For total Recovery Act jobs numbers in American Samoa go to www.recovery.gov

7

American Samoa | Building Energy Codes Program  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

American Samoa American Samoa Last updated on 2012-08-21 Commercial Residential Code Change Current Code None Statewide DOE Determination ASHRAE Standard 90.1-2007: No ASHRAE Standard 90.1-2010: No Current Code None Statewide DOE Determination 2009 IECC: No 2012 IECC: No Code Change Process Legislative Code Change Cycle None Timeline of Cycle None Adoption Process Standards are adopted through legislation. Background The Uniform Building Code is administered and enforced by the government public works department. Popular Links Status of State Energy Codes Status of State Energy Codes Select a state Alabama Alaska American Samoa Arizona Arkansas California Colorado Connecticut Delaware Florida Georgia Guam Hawaii Idaho Illinois Indiana Iowa Kansas Kentucky Louisiana Maine Maryland Massachusetts Michigan Minnesota Mississippi Missouri Montana

8

American Samoa Initial Technical Assessment Report  

SciTech Connect (OSTI)

This document is an initial energy assessment for American Samoa, the first of many steps in developing a comprehensive energy strategy. On March 1, 2010, Assistant Secretary of the Interior Tony Babauta invited governors and their staff from the Interior Insular Areas to meet with senior principals at the National Renewable Energy Laboratory (NREL). Meeting discussions focused on ways to improve energy efficiency and increase the deployment of renewable energy technologies in the U.S. Pacific Territories. In attendance were Governors Felix Camacho (Guam), Benigno Fitial (Commonwealth of the Northern Mariana Islands), and Togiola Tulafono, (American Samoa). This meeting brought together major stakeholders to learn and understand the importance of developing a comprehensive strategic plan for implementing energy efficiency measures and renewable energy technologies. For several decades, dependence on fossil fuels and the burden of high oil prices have been a major concern but never more at the forefront as today. With unstable oil prices, the volatility of fuel supply and the economic instability in American Samoa, energy issues are a high priority. In short, energy security is critical to American Samoa's future economic development and sustainability. Under an interagency agreement, funded by the Department of Interior's Office of Insular Affairs, NREL was tasked to deliver technical assistance to the islands of American Samoa. Technical assistance included conducting an initial technical assessment to define energy consumption and production data, establish an energy consumption baseline, and assist with the development of a strategic plan. The assessment and strategic plan will be used to assist with the transition to a cleaner energy economy. NREL provided an interdisciplinary team to cover each relevant technical area for the initial energy assessments. Experts in the following disciplines traveled to American Samoa for on-island site assessments: (1) Energy Efficiency and Building Technologies; (2) Integrated Wind-Diesel Generation; (3) Transmission and Distribution; (4) Solar Technologies; and (5) Biomass and Waste-to-Energy. In addition to these core disciplines, team capabilities also included expertise in program analysis, project financing, energy policy and energy planning. The intent of the technical assessment was to provide American Samoa with a baseline energy assessment. From the baseline, various scenarios and approaches for deploying cost effective energy efficiency and renewable energy technologies could be created to meet American Samoa's objectives. The information provided in this energy assessment will be used as input in the development of a draft strategic plan and the development of scenarios and strategies for deploying cost-effective energy efficiency and renewable products.

Busche, S.; Conrad, M.; Funk, K.; Kandt, A.; McNutt, P.

2011-09-01T23:59:59.000Z

9

American Samoa's Rebate Program Brings ENERGY STAR to Island | Department  

Broader source: Energy.gov (indexed) [DOE]

American Samoa's Rebate Program Brings ENERGY STAR to Island American Samoa's Rebate Program Brings ENERGY STAR to Island American Samoa's Rebate Program Brings ENERGY STAR to Island August 13, 2010 - 12:00pm Addthis American Samoa is located in the South Pacific Ocean, with temperature around 80 degrees year round. | Photo courtesy of Maleleg American Samoa is located in the South Pacific Ocean, with temperature around 80 degrees year round. | Photo courtesy of Maleleg Lindsay Gsell American Samoa, a small island of 66,000 residents in the Pacific Ocean, is a warm 80 degrees almost year round, but during the summer, the humidity can make it feel downright hot. Because of its remote location, appliances and electricity are costly - and until recently, home air conditioning units were fairly rare. Now thanks to a $100,000 grant through the American Recovery and

10

AMERICAN SAMOA RECOVERY ACT SNAPSHOT | Department of Energy  

Energy Savers [EERE]

clean energy projects, from energy efficiency and the smart grid to solar power and biofuels. Through these investments, American Samoa's businesses, universities, non-profits,...

11

American Samoa - Search - U.S. Energy Information Administration (EIA)  

U.S. Energy Information Administration (EIA) Indexed Site

American Samoa American Samoa Profile American Samoa American Samoa Profile Territory Profile and Energy Estimates Change State/Territory Choose a U.S. State or Territory United States Alabama Alaska Arizona Arkansas California Colorado Connecticut Delaware District of Columbia Florida Georgia Hawaii Idaho Illinois Indiana Iowa Kansas Kentucky Louisiana Maine Maryland Massachusetts Michigan Minnesota Mississippi Missouri Montana Nebraska Nevada New Hampshire New Jersey New Mexico New York North Carolina North Dakota Ohio Oklahoma Oregon Pennsylvania Rhode Island South Carolina South Dakota Tennessee Texas Utah Vermont Virginia Washington West Virginia Wisconsin Wyoming U.S. Territories American Samoa Guam Northern Mariana Islands Puerto Rico US Virgin Islands Overview Data State Profiles Economy Reserves & Supply Imports & Exports Distribution & Marketing

12

Municipal solid waste energy conversion study on Guam and American Samoa  

SciTech Connect (OSTI)

In the Pacific Islands of Guam and Tutuila in American Samoa, conversion of municipal solid waste to useable energy forms - principally electricity but possibly steam - may hold promise for reducing economic dependence on imported petroleum. A secondary benefit may be derived from reduction of solid waste landfill requirements. At the preliminary planning stage, waste-to-energy facilities producing electricity appear technically and environmentally feasible. Economically, the projects appear marginal but could be viable under specific conditions related to capital costs, revenue from garbage collection and revenue from the sale of the energy generated. Grant funding for the projects would considerably enhance the economic viability of the proposed facilities. The projects appear sufficiently viable to proceed to the detailed planning stage. Such projects are not viable for the islands now emerging from the US Trust Territory of the Pacific Islands.

Not Available

1984-03-31T23:59:59.000Z

13

*Wright, D.J., Donahue, B.T., and Naar, D.F., 2002. Seafloor mapping and GIS coordination at America's remotest national marine danctuary (American Samoa), in Wright, D.J. (ed.), Undersea with GIS, ESRI Press, Redlands, California,  

E-Print Network [OSTI]

*Wright, D.J., Donahue, B.T., and Naar, D.F., 2002. Seafloor mapping and GIS coordination at America's remotest national marine danctuary (American Samoa), in Wright, D.J. (ed.), Undersea with GIS National Marine Sanctuary (American Samoa)* Dawn J. Wright Department of Geosciences Oregon State

Wright, Dawn Jeannine

14

Suitability of salt-gradient solar ponds for electrical power generation in the US Trust Territory of the Pacific Islands, Guam, and American Samoa  

SciTech Connect (OSTI)

The procedures and findings of a study to assess the suitability of salt-gradient solar ponds for base-load (firm) electricity generation in the US Trust Territory of the Pacific Islands (TTPI), Guam and American Samoa are described. The general conclusion is that solar pond power plants (SPPPs) are viable both technically and economically for some applications, possibly including atolls. The most practical immediate application would be to small and intermediate power users such as villages and airports. It is recommended that (1) at least one small SPPP be built immediately on a dry land site such as for the main village on Peleliu, Palau, (considered in this report) or at other identified feasible sites, and (2) that a design study be conducted to adapt the technology to atoll sites. This study was carried out by first reviewing all available literature on solar ponds and the regions concerned. All the regions in question were visited. Several sites were selected for specific study and SPPP conceptual designs were developed for these sites. These sites are (1) North Peleliu, Palau, with (2) Peleliu airport as an auxiliary site, (3) Aimeliik, Palau, and (4) atoll environments. Cultural, political, environmental and legal considerations were given equal weight with technical and economic factors, and locally resident persons were used as interpreters and liaisons. There exists strong support in the government and the community to develop these proposed site-specific SPPPs and land is available. Power needs were defined, construction and operation costs were calculated and performance was predicted for the site-specific designs. The results of the Palau site-specific studies were generalized to other areas and environments in the TTPI, Guam and American Samoa. An economic analysis of the SPPP conceptual design developed for Palau was made using the discounted cash flow method.

McCord, T.B.; Bathen, K.H.; Boesgaard, H.; Fanale, F.P.; McCord, C.S.; Scudder, R.J.; Weeks, D.D.; Yuen, J.W.L.

1982-11-01T23:59:59.000Z

15

A guidebook to alternative energy projects on American Samoa, The Commonwealth of the Northern Mariana Islands, The Federated States of Micronesia, Guam, and The Republics of the Marshall Islands and Palau. [Contains bibliography  

SciTech Connect (OSTI)

The purpose of this guidebook is to help transfer information concerning alternative energy projects that have been tried on the Pacific islands affiliated with the US. These islands include those in American Samoa, the Commonwealth of the Northern Mariana Islands, the Federated States of Micronesia (Kosrae, Pohnpei, Truk, and Yap), Guam, and the Republics of the Marshall Islands and Palau. Distances are long between islands and populations are sparse, making communication and the transfer of information particularly difficult. A project that works on American Samoa might be appropriate for Yap, but to get this information to the proper people on Yap in a reasonable period of time is extremely difficult. This book describes 100 alternative energy projects that have been tried on the islands since the mid-1970's. This description and record of what has been done to date should be a source of ideas for energy workers, reduce duplication of work, and help encourage successes by describing other successes and failures. Alternative energy projects are projects that use indigenous, renewable resources in order to reduce local dependency on imported petroleum for electricity or liquid fuels. The islands have an apparent abundance of natural resources for this purpose such as the sun, rivers, vegetation, the ocean, and wind; and, ideally, it should be relatively simple to convert these resources to electricity or fuel. However, there are problems unique to the remote, tropical Pacific that often appear insurmountable, and successes to date are the results of unusual persistence, hard work, and ingenuity of those on the islands. Projects are confined to those that actually develop or demonstrate hardware. These projects use the complete spectrum of alternative technologies such as biomass conversion, wind electric, solar water heating, photovoltaics, wind water pumping, hydroelectric, water desalination, and integrated systems. 381 refs., 85 figs.

Case, C.W.

1987-05-01T23:59:59.000Z

16

Albania 00-800-0010 American Samoa  

E-Print Network [OSTI]

-800-01-001 Palau SS Panama 800-0109 {Spanish} 800-2288 Papua New Guinea SS Paraguay Asuncion City 008-11-800 Peru

Fisher, Kathleen

17

Samoa: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Samoa: Energy Resources Samoa: Energy Resources Jump to: navigation, search Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"TERRAIN","zoom":5,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"390px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":-13.5833333,"lon":-172.3333333,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

18

Metering Systems  

Broader source: Energy.gov [DOE]

A variety of metering systems are currently on the market for Federal facility implementation. The information below outlines common metering system capabilities and common metering system components.

19

E-Print Network 3.0 - american graves protection Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Marine Sanctuary GIS Capacity Summary: Report, configuration notes American Samoa Spatial Data Infrastructure Maps GIS Data CDs Operating System... ) 12;Compiled by...

20

Metering Process  

Broader source: Energy.gov [DOE]

Developing and implementing a metering plan is highly dependent on the individual facility's needs, mission, metering equipment, and available infrastructure. One size does not fit all.

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Net Metering  

Broader source: Energy.gov [DOE]

In October 2009, the Regulatory Commission of Alaska (RCA) approved net metering regulations. These rules were finalized and approved by the lieutenant governor in January 2010 and became...

22

Net Metering  

Broader source: Energy.gov [DOE]

North Dakota's net-metering policy, adopted in 1991 by the state Public Service Commission (PSC), applies to renewable-energy systems and combined heat and power (CHP) systems up to 100 kilowatts ...

23

Net Metering  

Broader source: Energy.gov [DOE]

[http://nebraskalegislature.gov/FloorDocs/101/PDF/Final/LB436.pdf LB 436], signed in May 2009, established statewide net metering rules for all electric utilities in Nebraska. The rules apply to...

24

Net Metering  

Broader source: Energy.gov [DOE]

Nevada's original net-metering law for renewable-energy systems was enacted in 1997 and amended in 2001, 2003, 2005 and 2007. Systems up to one megawatt (MW) in capacity that generate electricity...

25

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Iowa Program Type Net Metering Provider Iowa Utilities Board Iowa's statutes do not explicitly authorize the Iowa Utilities Board (IUB) to mandate net metering, but this authority is implicit through the board's enforcement of PURPA and Iowa Code § 476.41 ''et seq.'' Iowa's net-metering subrule, adopted by the IUB in July 1984, applies to customers that generate electricity using alternate energy production facilities (AEPs). Net metering is available to all customer classes of Iowa's two investor-owned utilities -- MidAmerican Energy and Interstate Power and

26

Saturation meter  

DOE Patents [OSTI]

A saturation meter for use in a pressurized water reactor plant comprising a differential pressure transducer having a first and second pressure sensing means and an alarm. The alarm is connected to the transducer and is preset to activate at a level of saturation prior to the formation of a steam void in the reactor vessel.

Gregurech, S.

1984-08-01T23:59:59.000Z

27

Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Program Areas » Operations & Maintenance » Metering Program Areas » Operations & Maintenance » Metering Metering October 7, 2013 - 9:21am Addthis Historically, the Federal sector has lagged in metering applications. It is not uncommon to find one meter serving hundreds of Federal facilities. These master meters make it very difficult to manage energy use and are a primary driver for Federal metering requirements. To help Federal agencies meet these requirements, this section outlines strategies and resources surrounding metering best practices, including: Metering Systems: Overview of metering system capabilities and functionality as well as common components across various metering systems Metering Approaches: Description of the four primary approaches to metering, including required equipment common for each approach

28

Metering | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

the federal sector has lagged in metering applications. It is not uncommon to find one meter serving hundreds of federal facilities. These master meters make it very difficult to...

29

Western Meter Policy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

WESTERN AREA POWER ADMINISTRATION Meter Policy November 22, 2013 Western Area Power Administration Meter Policy Version: Final 11222013 2 | P a g e Table of Contents 1. Purpose...

30

Samoa-Pilot Program for Climate Resilience (PPCR) | Open Energy Information  

Open Energy Info (EERE)

Samoa-Pilot Program for Climate Resilience (PPCR) Samoa-Pilot Program for Climate Resilience (PPCR) Jump to: navigation, search Name Samoa-Pilot Program for Climate Resilience (PPCR) Agency/Company /Organization World Bank Sector Energy, Land Topics Background analysis, Finance, Implementation, Low emission development planning, Market analysis Website http://www.climateinvestmentfu Country Samoa UN Region Southern Asia References Pilot Program for Climate Resilience (PPCR)[1] Contents 1 Overview 2 Programs by Country 2.1 Bangladesh 2.2 Bolivia 2.3 Cambodia 2.4 Dominica 2.5 Grenada 2.6 Haiti 2.7 Jamaica 2.8 Mozambique 2.9 Nepal 2.10 Niger 2.11 Papua New Guinea 2.12 Saint Lucia 2.13 Saint Vincent and the Grenadines 2.14 Samoa 2.15 Tajikistan 2.16 Tonga 2.17 Yemen 2.18 Zambia 3 References Overview "The Pilot Program for Climate Resilience (PPCR), approved in November

31

Propeller Flow Meter  

E-Print Network [OSTI]

Propeller flow meters are commonly used to measure water flow rate. They can also be used to estimate irrigation water use. This publication explains how to select, install, read and maintain propeller flow meters....

Enciso, Juan; Santistevan, Dean; Hla, Aung K.

2007-10-01T23:59:59.000Z

32

Economics of Energy Metering  

E-Print Network [OSTI]

history of industrial usage and their mechanical simplicity. The Flow Technology Group divided orifice meters into three basic types -- Class A, B, and C. Class A meters are the ultimate current technology can provide. Their overall accuracy is ~l... cost for a Class A orifice is $45,000, excluding the computer cost. Class B meters have an accuracy of +2%. The transmitter analog outputs are usually recorded on charts. These meters are used for utilities accounting and non critical production...

Duncan, J. D.

1979-01-01T23:59:59.000Z

33

Federal Metering Requirements  

Broader source: Energy.gov (indexed) [DOE]

Metering Requirements Metering Requirements FUPWG - May 23, 2013 Brad Gustafson Federal Energy Management Program 2 42 USC 8253 - ENERGY MANAGEMENT REQUIREMENT (e) Metering By October 1, 2012, in accordance with guidelines established by the Secretary under paragraph (2), all Federal buildings shall, for the purposes of efficient use of energy and reduction in the cost of electricity used in such buildings, be metered. Each agency shall use, to the maximum extent practicable, advanced meters or advanced metering devices that provide data at least daily and that measure at least hourly consumption of electricity in the Federal buildings of the agency. Not later than October 1, 2016, each agency shall provide for equivalent metering of natural gas and steam, in accordance with guidelines established by the Secretary

34

EPAct 2005 Metering Guidance Overview  

Broader source: Energy.gov (indexed) [DOE]

EPAct 2005 Metering Guidance EPAct 2005 Metering Guidance Overview Dave Hunt Pacific Northwest National Laboratory Section 103 Requirements * What to meter - Building electric usage - All buildings * How to meter - Standard meters - Advanced meters * When - by 10/1/2012 FEMP's Response * Metering guidance document * Agency planning workshops * Metering training course * Metering Best Practices Guide (FY 2007) Important Dates * August 3, 2006 - agency plans due * As determined by individual agencies - site metering plans * October 1, 2012 - compliance deadline Issues * Funding * Practicability * EPAct time-based rate schedule * Agency policies/guidance Potential Roles for Utilities * Guidance/updates on time-based pricing * Metering services * Finance installations * Other? Useful Documents

35

Federal Energy Management Program: Metering  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Metering Metering Historically, the Federal sector has lagged in metering applications. It is not uncommon to find one meter serving hundreds of Federal facilities. These master meters make it very difficult to manage energy use and are a primary driver for Federal metering requirements. To help Federal agencies meet these requirements, this section outlines strategies and resources surrounding metering best practices, including: Metering Systems: Overview of metering system capabilities and functionality as well as common components across various metering systems. Metering Approaches: Description of the four primary approaches to metering, including required equipment common for each approach. Metering Process: Outline of the five step process typically used to evaluate, design, install, and implement Federal metering programs.

36

Energy Metering Audit Procedure  

E-Print Network [OSTI]

Energy Meterilg Audtt Procedure Wiliam S Whitaker Engineering Specialist T X E INC. laPorte Texas INTROOUCI'ION This paper describes the recent audit of the utility distriooticn meters in a petrochanica1 plant. These meters measure the steam..., cx:ndensate, natural gas, water, nitrogen and air flCMS to the different process units within the plant. This audit started as an attellPt to resolve discrepan::ies between the 650 PSIG steam distriootion and supply meters. Theoretically the sum...

Whitaker, W. S.

37

Federal Energy Management Program: Metering  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Metering to Metering to someone by E-mail Share Federal Energy Management Program: Metering on Facebook Tweet about Federal Energy Management Program: Metering on Twitter Bookmark Federal Energy Management Program: Metering on Google Bookmark Federal Energy Management Program: Metering on Delicious Rank Federal Energy Management Program: Metering on Digg Find More places to share Federal Energy Management Program: Metering on AddThis.com... Sustainable Buildings & Campuses Operations & Maintenance Federal Requirements Program Management Commissioning Metering Systems Approaches Process Computerized Maintenance Management Systems Maintenance Types Major Equipment Types Resources Contacts Greenhouse Gases Water Efficiency Data Center Energy Efficiency Industrial Facilities

38

Meter Expansion Plan Existing Multi-Space Meter  

E-Print Network [OSTI]

Meter Expansion Plan 11 35 9 7 10 20 12 11 12 46 23 15 15 60 23 Existing Multi-Space Meter Split Regulations 136 New Multi-Space Meter Visitor Only New Multi-Space Meter Split Regulations KEY 97 Updated 7/8/13 11 5 #12;HAVE.HAVE. UNION DR. 1 2 3 4 5 New Multi-space Meter After: 5 Meter Spaces Regulations

Duchowski, Andrew T.

39

Meters | OpenEI  

Open Energy Info (EERE)

Meters Meters Dataset Summary Description The UK Department of Energy and Climate Change (DECC) releases annual statistics on domestic and non-domestic electricity and gas consumption (and number of meters) at the Middle Layer Super Output Authority (MLSOA) and Intermediate Geography Zone (IGZ) level (there are over 950 of these subregions throughout England, Scotland and Wales). Both MLSOAs (England and Wales) and IGZs (Scotland) include a minimum of approximately 2,000 households. The electricity consumption data data is split by ordinary electricity and economy7 electricity usage. Source UK Department of Energy and Climate Change (DECC) Date Released March 25th, 2010 (4 years ago) Date Updated Unknown Keywords Electricity Consumption gas Meters regional

40

Utility Metering - AGL Resources  

Broader source: Energy.gov (indexed) [DOE]

AGL Resources AGL Resources Mike Ellis Director, AGL Energy Services Federal Utility Partnership Working Group Spring 2013 - May 22-23 San Francisco, CA Hosted by: Pacific Gas and Electric Company  Multiple LDCs with legacy metering equipment  Several use Itron 100G technology ◦ Mobile, once-a-month data collection ◦ Meter can store interval data for >30 days ◦ Meter technology could be leverage on fixed-base network, however there are no current plans for upgrade  Technology for capturing interval data is installed on case by case basis ◦ Customers on Interruptible Rate ◦ Large users  Electronic corrector installed on the meter ◦ Pressure and Temperature compensation  Typically data is retrieved once a day ◦ Transmission frequency impacts battery life

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

WOOD STREET METERED LOT  

E-Print Network [OSTI]

LOT E1 LOT O WOOD STREET METERED LOT LOT W5 LOT C4 LOT B4 LOT L LOT M MARSHFIELDAVENUE PAULINASTREET Clinical Sciences Building UI Hospital Wood Street Station Clinical Sciences North Grand Grounds Garden

Dai, Yang

42

Net Metering Resources  

Broader source: Energy.gov [DOE]

State net metering policies allow customers to produce onsite electricity and sell excess generation to the utility at a set price, which creates an incentive for private investment in distributed...

43

NASA's Metering Plan  

Energy Savers [EERE]

4 May '06 Response to Response to EPAct EPAct * Agency-Wide (17 sites) * All Energy Utilities * Potable Water * E-Survey (all sites) * Physical Survey (3 sites) * Metering...

44

Ashland Electric- Net Metering  

Broader source: Energy.gov [DOE]

In 1996, Ashland adopted a net-metering program that includes simple interconnection guidelines. The program encourages the adoption of renewable-energy systems by committing the city to purchase,...

45

Advanced Metering Infrastructure  

SciTech Connect (OSTI)

The report provides an overview of the development of Advanced Metering Infrastructure (AMI). Metering has historically served as the cash register for the utility industry. It measured the amount of energy used and supported the billing of customers for that usage. However, utilities are starting to look at meters in a whole different way, viewing them as the point of contact with customers in supporting a number of operational imperatives. The combination of smart meters and advanced communications has opened up a variety of methods for utilities to reduce operating costs while offering new services to customers. A concise look is given at what's driving interest in AMI, the components of AMI, and the creation of a business case for AMI. Topics covered include: an overview of AMI including the history of metering and development of smart meters; a description of the key technologies involved in AMI; a description of key government initiatives to support AMI; an evaluation of the current market position of AMI; an analysis of business case development for AMI; and, profiles of 21 key AMI vendors.

NONE

2007-10-15T23:59:59.000Z

46

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Energy Sources Solar Home Weatherization Wind Program Info State Massachusetts Program Type Net Metering Provider Department of Public Utilities In Massachusetts, the state's investor-owned utilities must offer net metering. Municipal utilities are not obligated to offer net metering, but they may do so voluntarily. (There are no electric cooperatives in Massachusetts.) Class I, Class II, Class III net metering facilities In Massachusetts, there are several categories of net-metering facilities.

47

Infants Prefer the Musical Meter of Their Own Culture: A Cross-Cultural Comparison  

E-Print Network [OSTI]

Infants Prefer the Musical Meter of Their Own Culture: A Cross-Cultural Comparison Gaye Soley to determine whether cultural background would influence their preferences for musical meter. In Experiment 1, American infants preferred Western over Balkan meter, whereas Turkish infants, who were familiar with both

Ahmad, Sajjad

48

Neutron dose equivalent meter  

DOE Patents [OSTI]

A neutron dose equivalent detector for measuring neutron dose capable of accurately responding to neutron energies according to published fluence to dose curves. The neutron dose equivalent meter has an inner sphere of polyethylene, with a middle shell overlying the inner sphere, the middle shell comprising RTV.RTM. silicone (organosiloxane) loaded with boron. An outer shell overlies the middle shell and comprises polyethylene loaded with tungsten. The neutron dose equivalent meter defines a channel through the outer shell, the middle shell, and the inner sphere for accepting a neutron counter tube. The outer shell is loaded with tungsten to provide neutron generation, increasing the neutron dose equivalent meter's response sensitivity above 8 MeV.

Olsher, Richard H. (Los Alamos, NM); Hsu, Hsiao-Hua (Los Alamos, NM); Casson, William H. (Los Alamos, NM); Vasilik, Dennis G. (Los Alamos, NM); Kleck, Jeffrey H. (Menlo Park, CA); Beverding, Anthony (Foster City, CA)

1996-01-01T23:59:59.000Z

49

Efficient Metering Schemes with Pricing  

E-Print Network [OSTI]

Efficient Metering Schemes with Pricing Barbara Masucci Dipartimento di Informatica ed Applicazioni and Pinkas [7] introduced metering schemes. They proposed metering schemes in which any server is able and proposed metering schemes with pricing. In their schemes any server is able to construct a proof which

Stinson, Douglas

50

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government General Public/Consumer Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Wind Solar Home Weatherization Program Info State Arkansas Program Type Net Metering Provider Arkansas Economic Development Commission In April 2001, Arkansas enacted legislation (HB 2325) directing the Arkansas Public Service Commission (PSC) to establish net-metering rules for certain renewable-energy systems.* The PSC approved final rules for net metering in July 2002. Subsequent legislation enacted in April 2007 (HB 2334) expanded the availability of net metering; increased the capacity

51

Elbow mass flow meter  

DOE Patents [OSTI]

Elbow mass flow meter. The present invention includes a combination of an elbow pressure drop generator and a shunt-type mass flow sensor for providing an output which gives the mass flow rate of a gas that is nearly independent of the density of the gas. For air, the output is also approximately independent of humidity.

McFarland, Andrew R. (College Station, TX); Rodgers, John C. (Santa Fe, NM); Ortiz, Carlos A. (Bryan, TX); Nelson, David C. (Santa Fe, NM)

1994-01-01T23:59:59.000Z

52

Federal Metering Requirements  

Broader source: Energy.gov [DOE]

Presentationgiven at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meetingcovers the 42 USC 8253 Energy Management Requirement; Executive Order 13514(g) High-Performance Sustainable Federal Buildings; federal metering needs, history, and status; and utility/agency opportunities.

53

A Benthic Terrain Classification Scheme for American Samoa Accepted for publication in Marine Geodesy, 2006  

E-Print Network [OSTI]

, invasive species, security training activities, offshore oil and gas exploration, and coral bleaching the western Pacific. #12;3 Introduction The high productivity of coral reef ecosystems demands a quantifiable to increasing coastal populations (Culliton 1998). Natural and anthropogenic processes threaten natural

Wright, Dawn Jeannine

54

Reconsidering Lapita Ancestry: Evidence of Material Change and Migration on Tutuila Island, American Samoa  

E-Print Network [OSTI]

and raw material provisioning accompany the noted cessation of pottery production ca. 1,500-1,700 B.P. Two identifiable forms of technological organization, attributed to the Ceramic Period and Monument Building Period components, are separated in time...

Welch, Daniel Ryan

2014-05-06T23:59:59.000Z

55

Metering Systems | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Systems Systems Metering Systems October 7, 2013 - 9:23am Addthis A variety of metering systems are currently on the market for Federal facility implementation. The information below outlines common metering system capabilities and common metering system components. Metering System Capabilities The capabilities and functionality of metering systems vary depending on the individual metering system. The following are some of the more common features used by Federal facilities. Data Recording: Advanced meters can record total energy resource consumption in addition to enhanced functions like time-of-use, peak demand, load survey, and power outage. Electrical meters may also be able to record data points such as voltage, current, and power factor. Total Consumption: The most basic data function, total consumption records

56

Flow metering valve  

DOE Patents [OSTI]

An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

Blaedel, Kenneth L. (Dublin, CA)

1985-01-01T23:59:59.000Z

57

Flow metering valve  

DOE Patents [OSTI]

An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

Blaedel, K.L.

1983-11-03T23:59:59.000Z

58

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Fed. Government Institutional Local Government Multi-Family Residential Nonprofit Schools State Government Savings Category Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State District of Columbia Program Type Net Metering Provider Washington State University Washington's net-metering law applies to systems up to 100 kilowatts (kW) in capacity that generate electricity using solar, wind, hydro, biogas from animal waste, or combined heat and power technologies (including fuel cells). All customer classes are eligible, and all utilities -- including municipal utilities and electric cooperatives -- must offer net metering.

59

A microwave impedance meter  

E-Print Network [OSTI]

A MICROWAVE IMPEDANCE METER A Thesis Virgil Layfaette 8oaz Submitted to the Graduate School of the Agricultural and Mechanical College oi' Texas in partial fulfillment of the requirements for the degree of MASTER OF SC I ENCE August 1 g61... and advice of Dr. J. P, German who suggested the research proj ct and rendered assistance when necessary. Further thanks are extended to the Electrical Engineering Faculty and Staff for their patience and suggestions, 1v CONTENTS LIST OF FIGURES...

Boaz, Virgil Layfaette

2012-06-07T23:59:59.000Z

60

Chevron facility focused on commercial orifice-meter research  

SciTech Connect (OSTI)

Research to determine the accuracy of commercial orifice meters for custody-transfer measurement has indicated that high-volume gas meters can be flow-proven while in such service. The research further yielded more accurate orifice-meter discharge coefficient equations (at Reynolds numbers greater than 4,000,000) than current equations of the International Standards Organization (ISO) and the American Petroleum Institute (API). These are partial findings of a major study conducted by Chevron Oil Field Research Co. at its Venice, La., calibration facility.

Jones, E.H.; Ferguson, K.R.

1987-07-27T23:59:59.000Z

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State Vermont Program Type Net Metering Provider Vermont Department of Public Service NOTE: Legislation enacted in May 2012 (HB475) further amends Vermont's net metering policy. Vermont's original net-metering legislation was enacted in 1998, and the law has been expanded several times subsequently. Any electric customer in Vermont may net meter after obtaining a Certificate of Public Good from the Vermont Public Service Board (PSB). Solar net metered systems 10 kilowatts

62

Metering Systems | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

categories: electrical and flow-related. Electrical meters can track whole-building energy use (e.g., utility meters), sub-panel energy use (e.g., lighting), or a specific end...

63

DSW_RMR Meter Policy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

WESTERN AREA POWER ADMINISTRATION WESTERN AREA POWER ADMINISTRATION Metering Policy Desert Southwest and Rocky Mountain Regions August 08, 2012 Western Meter Policy DSW and RMR Regions Version 1.0 08/08/2012 2 | P a g e Contents 1. Purpose......................................................................................................................................4 2. Scope .........................................................................................................................................4 3. General Meter Policy Requirements ............................................................................................5 4. Western Owned Facilities ............................................................................................................... 6

64

Portable wastewater flow meter  

DOE Patents [OSTI]

A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under fill pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

Hunter, Robert M. (320 S. Wilson Ave., Bozeman, MT 59715)

1999-02-02T23:59:59.000Z

65

Portable wastewater flow meter  

DOE Patents [OSTI]

A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under full pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

Hunter, Robert M. (320 S. Wilson Ave., Bozeman, MT 59715)

1990-01-01T23:59:59.000Z

66

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State North Carolina Program Type Net Metering Provider North Carolina Utilities Commission The North Carolina Utilities Commission (NCUC) requires the state's three investor-owned utilities -- Duke Energy, Progress Energy and Dominion North Carolina Power -- to make net metering available to customers that own and operate systems that generate electricity using solar energy, wind energy, hydropower, ocean or wave energy, biomass resources, combined heat and

67

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Missouri Program Type Net Metering Provider Missouri Public Service Commission Missouri enacted legislation in June 2007 (S.B. 54)* requiring all electric utilities -- investor-owned utilities, municipal utilities and electric cooperatives -- to offer net metering to customers with systems up to 100 kilowatts (kW) in capacity that generate electricity using wind energy, solar-thermal energy, hydroelectric energy, photovoltaics (PV), fuel cells

68

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Solar Home Weatherization Water Wind Program Info State Maryland Program Type Net Metering Provider Maryland Public Service Commission Note: The program web site listed above links to the Maryland Public Service Commission's Net Metering Working Group page, which contains a variety of information resources related to the ongoing implementation of net metering in Maryland, such as meeting agendas, minutes, and draft utility tariffs.

69

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Solar Home Weatherization Program Info State District of Columbia Program Type Net Metering Provider DC Public Service Commission In the District of Columbia (DC), net metering is currently available to residential and commercial customer-generators with systems powered by renewable-energy sources, combined heat and power (CHP), fuel cells and microturbines, with a maximum capacity of 1 megawatt (MW). The term "renewable energy sources" is defined as solar, wind, tidal, geothermal, biomass, hydroelectric power and digester gas. In October 2008, the Clean

70

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Commercial Heating & Cooling Manufacturing Buying & Making Electricity Hydrogen & Fuel Cells Water Energy Sources Solar Home Weatherization Wind Program Info State New Hampshire Program Type Net Metering Provider New Hampshire Public Utilities Commission New Hampshire requires all utilities selling electricity in the state to offer net metering to customers who own or operate systems up to one megawatt (1 MW) in capacity that generate electricity using solar, wind, geothermal, hydro, tidal, wave, biomass, landfill gas, bio-oil or

71

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Buying & Making Electricity Water Solar Home Weatherization Wind Program Info State Virginia Program Type Net Metering Provider Virginia Department of Mines, Minerals, and Energy '''''Note: In March 2011, Virginia enacted HB 1983, which increased the residential net-metering limit to 20 kW. However, residential facilities with a capacity of greater than 10 kW must pay a monthly standby charge. The Virginia State Corporation Commission approved standby charges for transmissions and distribution components as proposed by Virginia Electric and Power Company (Dominion Virginia Power) on November 3, 2011.'''''

72

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Industrial Residential Local Government Multi-Family Residential Nonprofit Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State West Virginia Program Type Net Metering Provider West Virginia Public Service Commission Net metering in West Virginia is available to all retail electricity customers. System capacity limits vary depending on the customer type and electric utility type, according to the following table. Customer Type IOUs with 30,000 customers or more IOUs with fewer than 30,000 customers, municipal utilities, electric cooperatives

73

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Wind Solar Home Weatherization Water Program Info State New York Program Type Net Metering Provider New York State Department of Public Service Note: In October 2012 the New York Public Service Commission (PSC) issued an order directing Central Hudson Gas and Electric to file net metering tariff revisions tripling the aggregate net metering cap for most systems from 1% of 2005 peak demand (12 MW) to 3% of 2005 peak demand (36 MW). The PSC issued another order in June 2013 to raise the aggregate net metering cap

74

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Wind Solar Home Weatherization Program Info State Illinois Program Type Net Metering Provider Illinois Commerce Commission '''''NOTE: Legislation enacted in 2011 and 2012 (S.B. 1652, H.B. 3036, and S.B. 3811) has changed several aspects of net metering in Illinois. For customers in competitive classes as of July 1, 2011, the law prescribes a dual metering and bill crediting system which does not meet the definition of net metering as the term is generally defined. Click here for information regarding competitive classes, and

75

Net Metering | Open Energy Information  

Open Energy Info (EERE)

Metering Metering Jump to: navigation, search For electric customers who generate their own electricity, net metering allows for the flow of electricity both to and from the customer,– typically through a single, bi-directional meter. With net metering, when a customer’'s generation exceeds the customer’'s use, the customer's electricity flows back to the grid, offsetting electricity consumed by the customer at a different time. In effect, the customer uses excess generation to offset electricity that the customer otherwise would have to purchase at the utility’'s full retail rate. Net metering is required by law in most states, but some of these laws only apply to investor-owned utilities,– not to municipal utilities or electric cooperatives. [1] Net Metering Incentives

76

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial General Public/Consumer Industrial Residential Fed. Government Local Government State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Water Solar Home Weatherization Wind Program Info State Oklahoma Program Type Net Metering Provider Oklahoma Corporation Commission Net metering has been available in Oklahoma since 1988 under Oklahoma Corporation Commission (OCC) Order 326195. The OCC's rules require investor-owned utilities and electric cooperatives under the commission's jurisdiction* to file net-metering tariffs for customer-owned renewable-energy systems and combined-heat-and-power (CHP) facilities up to 100 kilowatts (kW) in capacity. Net metering is available to all customer

77

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Wind Solar Home Weatherization Program Info State Ohio Program Type Net Metering Provider Ohio Public Utilities Commission '''''Note: In July 2012, the Public Utilities Commission of Ohio (PUCO) opened a docket ([http://dis.puc.state.oh.us/CaseRecord.aspx?CaseNo=12-2050-EL-ORD Case 12-0250-EL-RDR]) to review the net metering rules for investor-owned utilities. Details will be posted as more information is available.''''' Ohio's net-metering law requires electric distribution utilities to offer net metering to customers who generate electricity using wind energy, solar energy, biomass, landfill gas, hydropower, fuel cells or microturbines.

78

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Solar Home Weatherization Program Info State New Mexico Program Type Net Metering Provider New Mexico Public Regulation Commission Net metering is available to all "qualifying facilities" (QFs), as defined by the federal Public Utility Regulatory Policies Act of 1978 (PURPA)*, which pertains to systems up to 80 megawatts (MW) in capacity. Previously, net metering in New Mexico was limited to systems up to 10 kilowatts (kW) in capacity. Net-metered customers are credited or paid for any monthly net excess generation (NEG) at the utility's avoided-cost rate. If a customer has net

79

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Net Metering Net Metering < Back Eligibility Commercial Fed. Government Local Government Residential State Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Hawaii Program Type Net Metering Provider Hawaii Public Utilities Commission NOTE: Kauai Island Electric Cooperative's (KIUC) net metering program has reached its capacity and has implemented a Net Energy Metering Pilot Program. Hawaii's original net-metering law was enacted in 2001 and expanded in 2004 by HB 2048, which increased the eligible capacity limit of net-metered systems from 10 kilowatts (kW) to 50 kW. In 2005, the law was further amended by SB 1003, which authorized the Hawaii Public Utilities Commission

80

Advanced Metering - Using advanced Metering to Improve Building...  

Broader source: Energy.gov (indexed) [DOE]

bills *Tenant energy use (sub metering) *Identifying best rates *Participating in demand response programs OptimizeReview performance *Diagnose equipment & systems operations...

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

2586 VOLUME 10J O U R N A L O F C L I M A T E 1997 American Meteorological Society  

E-Print Network [OSTI]

) comprise former territories administered under a United Nations trusteeship [now the Federated States of Micronesia (FSM), Republic of Palau, the Commonwealth of Northern Mariana Islands, and the Republic of the Marshall Islands] as well as older U.S. territories (the Territory of Guam, Wake Island, and American Samoa

Hawai'i at Manoa, University of

82

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Water Energy Sources Solar Home Weatherization Wind Program Info State Minnesota Program Type Net Metering Provider Minnesota Department of Commerce '''''Note: H.F. 729, enacted in May 2013, includes many changes to Minnesota's net metering law. These changes are described above, but most will not take effect until rules are implemented at the PUC. The below summary reflects the current rules.''''' Minnesota's net-metering law, enacted in 1983, applies to all investor-owned utilities, municipal utilities and electric cooperatives. All "qualifying facilities" less than 40 kilowatts (kW) in capacity are

83

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Energy Sources Solar Home Weatherization Wind Program Info State Pennsylvania Program Type Net Metering Provider Pennsylvania Public Utility Commission Note: In March 2012 the Pennsylvania Public Utilities Commission (PUC) issued a Final Order (Docket M-2011-2249441) approving the use of third-party ownership models (i.e., system leases or retail power purchase agreements) in conjunction with net metering. The Order allows these types of arrangements for net metered systems, subject to a restriction that the

84

Electric Metering | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electric Electric Metering Electric Metering Saving Money by Saving Energy The Department of Energy has installed meters in the James Forrestal Building that will enable DOE to measure electricity use and costs in its headquarters facility. You may explore this data further by visiting our Forrestal Metering Dashboard at the following website: http://forrestal.nrel.gov The Forrestal electric meters provide daily read-outs and comparison of data on electricity consumption for overhead lighting and power outlets. The purpose is to measure the electricity used by equipment that building occupants can control. Data is collected and reported by zones throughout Forrestal's north, south and west buildings. See the Forrestal metering zone map, below, for details on the zones.

85

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Wind Solar Home Weatherization Program Info State Louisiana Program Type Net Metering Provider Louisiana Public Service Commission '''''Note: Ongoing proceedings related to net metering can be found in Docket R-31417.''''' Louisiana enacted legislation in June 2003 establishing net metering. Modeled on Arkansas's law, Louisiana's law requires investor-owned utilities, municipal utilities and electric cooperatives to offer net metering to customers that generate electricity using solar, wind, hydropower, geothermal or biomass resources. Fuel cells and microturbines that generate electricity entirely derived from renewable resources are

86

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Multi-Family Residential Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Connecticut Program Type Net Metering Provider Public Utilities Regulatory Authority Connecticut's two investor-owned utilities -- Connecticut Light and Power Company (CL&P) and United Illuminating Company (UI) -- are required to provide net metering to customers that generate electricity using "Class I" renewable-energy resources, which include solar, wind, landfill gas, fuel

87

O&M Metering Guidance  

Broader source: Energy.gov [DOE]

Presentation covers the O&M Metering Guidance and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Rapid City, South Dakota.

88

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Agricultural Agricultural Commercial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Kentucky Program Type Net Metering Provider Kentucky Public Service Commission In April 2008, Kentucky enacted legislation that expanded its net metering law by requiring utilities to offer net metering to customers that generate electricity with photovoltaic (PV), wind, biomass, biogas or hydroelectric systems up to 30 kilowatts (kW) in capacity. The Kentucky Public Service Commission (PSC) issued rules on January 8, 2009. Utilities had 90 days from that date to file tariffs that include all terms and conditions of their net metering programs, including interconnection.

89

Impact of orifice metering uncertainties  

SciTech Connect (OSTI)

In a recent utility study, attributed 38% of its unaccounted-for UAF gas to orifice metering uncertainty biasing caused by straightening vanes. How this was determined and how this applied to the company's orifice meters is described. Almost all (97%) of the company's UAF gas was found to be attributed to identifiable accounting procedures, measurement problems, theft and leakage.

Stuart, J.W. (Pacific Gas and Electric Co., San Francisco, CA (USA))

1990-12-01T23:59:59.000Z

90

Wavelength meter having elliptical wedge  

DOE Patents [OSTI]

A wavelength meter is disclosed which can determine the wavelength of a laser beam from a laser source within an accuracy range of two parts in 10.sup.8. The wavelength meter has wedge having an elliptically shaped face to the optical path of the laser source and includes interferometer plates which form a vacuum housing.

Hackel, Richard P. (Livermore, CA); Feldman, Mark (Livermore, CA)

1992-01-01T23:59:59.000Z

91

Wavelength meter having elliptical wedge  

DOE Patents [OSTI]

A wavelength meter is disclosed which can determine the wavelength of a laser beam from a laser source within an accuracy range of two parts in 10[sup 8]. The wavelength meter has wedge having an elliptically shaped face to the optical path of the laser source and includes interferometer plates which form a vacuum housing. 7 figs.

Hackel, R.P.; Feldman, M.

1992-12-01T23:59:59.000Z

92

Gerson Recinos Onramp Metering System  

E-Print Network [OSTI]

Gerson Recinos Onramp Metering System Using Arduino and Processing Overview­ For this project I built an Onramp Metering System using Arduino and Processing. The Microcontroller used was Arduino (based on Atmel168) and the programming languages were Processing and Wiring (derivative

Kachroo, Pushkin

93

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Solar Water Wind Program Info State New Jersey Program Type Net Metering Provider New Jersey Board of Public Utilities New Jersey's net-metering rules apply to all residential, commercial and industrial customers of the state's investor-owned utilities and energy suppliers (and certain competitive municipal utilities and electric cooperatives). Systems that generate electricity using solar, wind, geothermal, wave, tidal, landfill gas or sustainable biomass resources, including fuel cells (all "Class I" technologies under the state RPS), are

94

Metering Process | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Process Process Metering Process October 7, 2013 - 9:34am Addthis Developing and implementing a metering plan is highly dependent on the individual facility's needs, mission, metering equipment, and available infrastructure. One size does not fit all. The following guidelines outline the typical process for planning and implementing a metering program. Establish Program Goals and Objectives Establishing program goals and objectives is the critical first step for all metering programs. While the ultimate goal is usually measuring and lowering utility use or costs, the objectives needed to get this done varies. Examples of program objectives include: To fully enable energy bill allocation throughout the facility To effectively manage electric loads and minimize costs under a

95

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Michigan Program Type Net Metering Provider Michigan Public Service Commission '''''The MPSC is reviewing state interconnection and net metering policies in [http://efile.mpsc.state.mi.us/efile/viewcase.php?casenum=15919&submit.x=... Case U-15919].''''' In October 2008, Michigan enacted legislation (P.A. 295) requiring the Michigan Public Service Commission (PSC) to establish a statewide net metering program for renewable-energy systems within 180 days. On May 26, 2009 the Michigan Public Service Commission (PSC) issued an order formally

96

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Home Weatherization Wind Program Info State Colorado Program Type Net Metering Provider Colorado Public Utilities Commission [http://www.leg.state.co.us/clics/clics2009a/csl.nsf/fsbillcont3/571064D8... Senate Bill 51] of April 2009 made several changes, effective September 1, 2009, to the state's net metering rules for investor-owned utilities, as they apply to solar-electric systems. These changes include converting the maximum system size for solar-electric systems from two megawatts (MW) to 120% of the annual consumption of the site; redefining a site to include

97

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Industrial Residential Fed. Government General Public/Consumer Local Government Low-Income Residential Multi-Family Residential Nonprofit Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Wind Program Info State California Program Type Net Metering Provider California Public Utilities Commission California's net-metering law originally took effect in 1996 and applies to all utilities with one exception*. The law has been amended numerous times since its enactment, most recently by AB 327 of 2013. '''Eligible Technologies''' The original law applied to wind-energy systems, solar-electric systems and hybrid (wind/solar) systems. In September 2002, legislation (AB 2228)

98

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Alternative Fuel Vehicles Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Delaware Program Type Net Metering Provider Delaware Public Service Commission In Delaware, net metering is available to any customer that generates electricity using solar, wind or hydro resources, anaerobic digesters, or fuel cells capable of being powered by renewable fuels. Grid-interactive electric vehicles are also eligible for net metering treatment for electricity that they put on the grid, although these vehicles do not themselves generate electricity. The maximum capacity of a net-metered system is 25 kilowatts (kW) for residential customers; 100 kW for farm customers on residential rates; two megawatts (MW) per meter for

99

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE 4,900 METERS NYLON LINE, CONTINUOUS 700 METERS KEO 1: DATE: DATE: MOORING: SCOPE: NOAA-PMEL-KE 1.4:1 TC5 METERS 700 METERS WIRE ROPE FAIRING TO 500 METERS TC10 METERS 50 METERS 25 METERS TC TC 75 METERS TC 100 METERS TP 150 METERS TC 200 METERS TC 300 METERS

100

Federal Energy Management Program: Metering Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Metering Systems Metering Systems to someone by E-mail Share Federal Energy Management Program: Metering Systems on Facebook Tweet about Federal Energy Management Program: Metering Systems on Twitter Bookmark Federal Energy Management Program: Metering Systems on Google Bookmark Federal Energy Management Program: Metering Systems on Delicious Rank Federal Energy Management Program: Metering Systems on Digg Find More places to share Federal Energy Management Program: Metering Systems on AddThis.com... Sustainable Buildings & Campuses Operations & Maintenance Federal Requirements Program Management Commissioning Metering Systems Approaches Process Computerized Maintenance Management Systems Maintenance Types Major Equipment Types Resources Contacts Greenhouse Gases Water Efficiency

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Smart meters | Open Energy Information  

Open Energy Info (EERE)

meters meters Jump to: navigation, search Smart meters are part of the initiative to install a smart grid to better power the United States in the coming year, helping incorporate renewable energy technologies into the grid while also making the existing grid more efficient. About Smart Grid Smartgridlogo.png The purpose of smart meters is to aid development of the United States Smart Grid initiative. The purpose of Smart Grid "to support the modernization of the nation's electricity transmission and distribution system to maintain a reliable and secure electricity infrastructure, outlined in Title XIII of the Energy Independence and Security Act of 2007 (PDF 821 KB)." More in-depth information can be found at SmartGrid.gov. It is believed that the implementation of a new Smart Grid "will make our grid more secure

102

Electric Metering | Department of Energy  

Office of Environmental Management (EM)

has installed meters in the James Forrestal Building that will enable DOE to measure electricity use and costs in its headquarters facility. You may explore this data further by...

103

Valley Electric Association- Net Metering  

Broader source: Energy.gov [DOE]

The Board of Directors for Valley Electric Association (VEA) approved net metering in April 2008. The rules apply to systems up to 30 kW, though owners of larger systems may be able to negotiate...

104

Gamma radiation field intensity meter  

DOE Patents [OSTI]

A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

Thacker, L.H.

1995-10-17T23:59:59.000Z

105

Gamma radiation field intensity meter  

DOE Patents [OSTI]

A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

Thacker, L.H.

1994-08-16T23:59:59.000Z

106

Gamma radiation field intensity meter  

DOE Patents [OSTI]

A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

Thacker, Louis H. (Knoxville, TN)

1995-01-01T23:59:59.000Z

107

Gamma radiation field intensity meter  

DOE Patents [OSTI]

A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

Thacker, Louis H. (Knoxville, TN)

1994-01-01T23:59:59.000Z

108

START USING THE NEW ONLINE METER  

E-Print Network [OSTI]

START USING THE NEW ONLINE METER REQUEST FORM TOOL CAS login Logging in with your Princeton Net and convenient way for departments to send outgoing metered mail with Mail Services! The new Online Meter Request

Singh, Jaswinder Pal

109

BPA Metering Services Editing and Estimating Procedures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Editing and Estimating Interval Data 1. Introduction This section defines the meter interval data editing and estimation techniques performed by BPA's Metering Services...

110

DVS5.2 METERS 8 METERS OCR507, STOR-X DATA LOGGER  

E-Print Network [OSTI]

DVS5.2 METERS 10 METERS 8 METERS OCR507, STOR-X DATA LOGGER 16" BATTERY HOUSING TC INVERTED5 METERS 1" SAS INDUCTIVE CABLE BREAKOUT RADAR REFLECTOR OS PAPA RECOVERY HANDLE 1 METER-SBE 37 MICROCAT TC HUMIDITY (FLEX) CTD/GTD/O2 4 METERS WETLabs FLNTUSB FLUOROMETER DOUBLE NUT AND TORQUE ALL LOAD CELL NUTS

111

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Agricultural Agricultural Commercial Fed. Government Industrial Institutional Local Government Multi-Family Residential Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Heating & Cooling Commercial Heating & Cooling Wind Program Info State Indiana Program Type Net Metering Provider Indiana Utility Regulatory Commission The Indiana Utility Regulatory Commission (IURC) adopted rules for net metering in September 2004, requiring the state's investor-owned utilities (IOUs) to offer net metering to all electric customers. The rules, which apply to renewable energy resource projects [defined by IC 8-1-37-4(a)(1) - (8)] with a maximum capacity of 1 megawatt (MW), include the following

112

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Agricultural Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Oregon Program Type Net Metering Oregon has established separate net-metering programs for the state's primary investor-owned utilities (PGE and PacifiCorp), and for its municipal utilities and electric cooperatives. '''PGE and PacifiCorp Customers''' The Oregon Public Utilities Commission (PUC) adopted new rules for net metering for PGE and PacifiCorp customers in July 2007, raising the individual system limit from 25 kilowatts (kW) to two megawatts (MW) for non-residential applications. (The rules do not apply to customers of Idaho

113

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Institutional Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State Arizona Program Type Net Metering Provider Arizona Corporation Commission Net metering is available to customers who generate electricity using solar, wind, hydroelectric, geothermal, biomass, biogas, combined heat and power (CHP) or fuel cell technologies. The ACC has not set a firm kilowatt-based limit on system size capacity; instead, systems must be sized to not exceed 125% of the customer's total connected load. If there is no available load data for the customer, the generating system may not

114

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Industrial Industrial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Water Energy Sources Solar Home Weatherization Wind Program Info State Wisconsin Program Type Net Metering Provider Public Service Commission of Wisconsin The Public Service Commission of Wisconsin (PSC) issued an order on January 26, 1982 requiring all regulated utilities to file tariffs allowing net metering to customers that generate electricity with systems up to 20 kilowatts (kW)* in capacity. The order applies to investor-owned utilities and municipal utilities, but not to electric cooperatives. All distributed-generation (DG) systems, including renewables and combined heat and power (CHP), are eligible. There is no limit on total enrollment.

115

Station design using orifice meters  

SciTech Connect (OSTI)

This paper reports that proper meter station design using gas orifice meters must include consideration of a number of factors to minimize operation and maintenance problems while obtaining the best accuracy over the life of the station. A station should provide accuracy, be safe, functional, economical and free of undue maintenance. It should comply with all codes, reports and specifications but most of all it should be able to comply with terms set forth in the contract. All measuring stations should be designed with considerations of growth or reductions in volume. It should be attractive and built to last for many years.

Upp, E.L. (Daniel Industries, Inc., Houston, TX (United States))

1992-07-01T23:59:59.000Z

116

Hardware Metering: A Survey Farinaz Koushanfar  

E-Print Network [OSTI]

Chapter 1 Hardware Metering: A Survey Farinaz Koushanfar Abstract This chapter provides the first comprehensive overview of hard- ware integrated circuits (IC) protection by metering. Hardware metering, or IC metering refers to mechanisms, methods, and protocols that enable track- ing of the ICs post

117

meter:alittlelonger kilometer:alittlemore  

E-Print Network [OSTI]

Yard Meter meter:alittlelonger thanayard mile kilometer kilometer:alittlemore thanhalfamile gramM1000000 gigaG1000000000 COMMONPREFIXES 1 8765432 9 161514131211101 8765432 9 16151413121110 cm Yard Meter meter:alittlelonger thanayard mile kilometer kilometer:alittlemore thanhalfamile gram

118

Federal Energy Management Program: Metering Process  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Process Process to someone by E-mail Share Federal Energy Management Program: Metering Process on Facebook Tweet about Federal Energy Management Program: Metering Process on Twitter Bookmark Federal Energy Management Program: Metering Process on Google Bookmark Federal Energy Management Program: Metering Process on Delicious Rank Federal Energy Management Program: Metering Process on Digg Find More places to share Federal Energy Management Program: Metering Process on AddThis.com... Sustainable Buildings & Campuses Operations & Maintenance Federal Requirements Program Management Commissioning Metering Systems Approaches Process Computerized Maintenance Management Systems Maintenance Types Major Equipment Types Resources Contacts Greenhouse Gases Water Efficiency Data Center Energy Efficiency

119

Alternative Fuels Data Center: Natural Gas Metering  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Natural Gas Metering Natural Gas Metering to someone by E-mail Share Alternative Fuels Data Center: Natural Gas Metering on Facebook Tweet about Alternative Fuels Data Center: Natural Gas Metering on Twitter Bookmark Alternative Fuels Data Center: Natural Gas Metering on Google Bookmark Alternative Fuels Data Center: Natural Gas Metering on Delicious Rank Alternative Fuels Data Center: Natural Gas Metering on Digg Find More places to share Alternative Fuels Data Center: Natural Gas Metering on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Natural Gas Metering Individuals who use natural gas for residential or other tax-free purposes may not use natural gas in motor vehicles unless the natural gas is obtained through a separate meter installed by the alternative fuels

120

2,270 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,270 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO 1" NYLON 3/4" SAS EYE INTO EYE SPLICE ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 697.4 METERS 7/16" WIRE ROPE 7.1 METERS 10 METERS 37.1 METERS 75 METERS 100 METERS 125 METERS 225

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

2,309 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,309 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO 1" NYLON EYE INTO EYE SPLICE 20 METERS 1 1/8" NYLON 697.4 METERS 7/16" WIRE ROPE 36.1 METERS TC inverted35 METERS 40 METERS 700 METERS 3/4" SAS, Wrench tighten. ** 3/4" SAS WITH BUSHING, Wrench tighten. ** .5

122

Metering Approaches | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Approaches Approaches Metering Approaches October 7, 2013 - 9:24am Addthis Metering approaches vary depending on facility design and intended purpose (e.g., administrative offices, laboratory, warehouse, etc.). No one approach fits all applications. In fact, different approaches are often needed at different times. For example, a different approach is needed depending on whether the program is trying to verify utility rates, implement demand response or load management programs, or support certification efforts. One-Time Measurements One-time measurements are useful in many baseline activities to understand instantaneous energy use, equipment performance, or loading. These measurements become particularly useful in trending equipment performance over time. For example, one-time measurements are useful when an energy-efficiency

123

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Residential Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Wyoming Program Type Net Metering Provider Wyoming Public Service Commission Wyoming enacted legislation in February 2001 that established statewide net metering. The law applies to investor-owned utilities, electric cooperatives and irrigation districts. Eligible technologies include solar, wind, biomass and hydropower systems up to 25 kilowatts (kW) in capacity. Systems must be intended primarily to offset part or all of the customer-generator's requirements for electricity. Net excess generation (NEG) is treated as a kilowatt-hour (kWh) credit or other compensation on the customer's following bill.* When an annual period ends, a utility will purchase unused credits at the utility's avoided-cost

124

Electrical Metering Equipment and Sensors Appendix D -Electrical Metering Equipment and Sensors  

E-Print Network [OSTI]

Appendix D ­ Electrical Metering Equipment and Sensors #12;D.1 Appendix D - Electrical Metering schedules, and view system status from the convenience of a standard web-browser. D.2 Metering Data Logger

125

Federal Building Metering Guidance (Per U.S.C. 8253(e), Metering of Energy Use)  

Broader source: Energy.gov [DOE]

Guidance defines which Federal buildings are appropriate to meter, provides metering prioritization recommendations for agencies with limited resources, and discusses the requirement for agencies to submit metering implementation plans the U.S. Department of Energy.

126

Government Program Briefing: Smart Metering  

Office of Energy Efficiency and Renewable Energy (EERE)

This document is adapted and updated from a memo delivered to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the U.S. Department of Energy (DOE) Project Officer in March 2008. This briefing piece provides an overview of the benefits, costs, and challenges of smart metering.

127

An analysis of polymorphisms among isozyme loci in dark and light Drosophila ananassae strains from American and Western Samoa  

Science Journals Connector (OSTI)

...studies of natural populations of Drosophila: I. Pacific island populations," Univ. of Texas Publication, in press. I Futch, D. G., "A study of speciation in South Pacific populations of D. ananassae," Univ. of Texas Publication, in press...

F M Johnson; C G Kanapi; R H Richardson; M R Wheeler; W S Stone

1966-01-01T23:59:59.000Z

128

Idaho Power - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Idaho Power - Net Metering < Back Eligibility Agricultural Commercial Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Idaho Program Type Net Metering Provider Idaho Power Company Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has developed a net-metering tariff that has been approved by the Idaho Public Utilities Commission (PUC). The framework of the utilities' net-metering programs is similar, in that each utility: (1) offers net metering to customers that generate electricity using solar, wind, hydropower, biomass or fuel cells; (2) limits residential systems to

129

LADWP - Net Metering (California) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering (California) Net Metering (California) LADWP - Net Metering (California) < Back Eligibility Agricultural Commercial General Public/Consumer Industrial Residential Savings Category Solar Buying & Making Electricity Wind Program Info State California Program Type Net Metering Provider Los Angeles Department of Water and Power LADWP allows its customers to net meter their photovoltaic (PV), wind, and hybrid systems with a capacity of not more than one megawatt. LADWP will provide the necessary metering equipment unless an installation requires atypical metering equipment. In these cases the customer must cover the additional metering expenses. The customer must also pay any related interconnection fees. Excess kilowatt-hours (kWh) generated by the customer's system will be

130

greenMeter | Open Energy Information  

Open Energy Info (EERE)

greenMeter greenMeter Jump to: navigation, search Tool Summary LAUNCH TOOL Name: greenMeter Agency/Company /Organization: Hunter Research & Technology Sector: Energy Focus Area: Energy Efficiency Resource Type: Software/modeling tools User Interface: Mobile Device Website: hunter.pairsite.com/greenmeter/ Web Application Link: hunter.pairsite.com/greenmeter/ Cost: Paid greenMeter Screenshot References: greenMeter[1] Logo: greenMeter greenMeter is an app for the iPhone and iPod Touch that computes your vehicle's power and fuel usage characteristics and evaluates your driving to increase efficiency, reduce fuel consumption and cost, and lower your environmental impact. Results are displayed in real time, while driving, to give instantaneous feedback. Overview Using accelerometer data and the advanced physics engine from the gMeter

131

Avista Utilities - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Avista Utilities - Net Metering Avista Utilities - Net Metering Avista Utilities - Net Metering < Back Eligibility Agricultural Commercial Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Idaho Program Type Net Metering Provider Avista Utilities Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has developed a net-metering tariff that has been approved by the Idaho Public Utilities Commission (PUC). The framework of the utilities' net-metering programs is similar, in that each utility: (1) offers net metering to customers that generate electricity using solar,

132

NASA's Metering Plan | Department of Energy  

Energy Savers [EERE]

NASA's Metering Plan NASA's Metering Plan Presentation covers NASA's Meterting Plan and is given at the FUPWG 2006 Spring meeting, held on May 3-4, 2006 in Atlanta, Georgia....

133

Metered Mail Form International Mail Only  

E-Print Network [OSTI]

Metered Mail Form International Mail Only Charge to Department USPS First Class Mail International International Metered Mail Form and must be kept separate from all other domestic mail. · International mail

Palmeri, Thomas

134

Heating Energy Meter Validation for Apartments  

E-Print Network [OSTI]

Household heat metering is the core of heating system reform. Because of many subjective and objective factors, household heat metering has not been put into practice to a large extent in China. In this article, the research subjects are second...

Cai, B.; Li, D.; Hao, B.

2006-01-01T23:59:59.000Z

135

Energy Measurement Techniques for Smart Metering  

Science Journals Connector (OSTI)

This chapter discusses topology, architecture and circuit design of energy measurement unit for Smart Metering. The chapter establishes step-by-step design methodology of energy measurement unit of a smart meter ...

Sumit Adhikari

2013-01-01T23:59:59.000Z

136

DOE Releases Federal Building Metering Guidance  

Broader source: Energy.gov [DOE]

The guidance requires federal agencies to review, revise, and submit to FEMP its metering implementation plan within one year.

137

Metering Schemes for General Access Structures  

E-Print Network [OSTI]

Metering Schemes for General Access Structures Barbara Masucci Dipartimento di Informatica ed, Canada E­mail: dstinson@cacr.math.uwaterloo.ca Abstract A metering scheme is a method by which an audit time frame. In this paper we construct metering schemes for more general access structures, which

Stinson, Douglas

138

A PHOTOELECTRIC CURRENT METER Marine Biological Laboratory!  

E-Print Network [OSTI]

330 A PHOTOELECTRIC CURRENT METER Marine Biological Laboratory! WOODS HOLE, MASS. SPECIAL CURRENT METER by H. C. Boyar Fishery Research Biologist Bureau of Commercial Fisheries Biological. March 1960 #12;#12;TABLE OF CONTENTS Page Introduction 1 Description and operation of the meter

139

THE ELECTRICAL RESISTIVITY METER IN FISHERY INVESTIGATIONS  

E-Print Network [OSTI]

THE ELECTRICAL RESISTIVITY METER IN FISHERY INVESTIGATIONS I Marine Biological Laboratory! WOODS RESISTIVITY METER IN FISHERY INVESTIGATIONS By Robert E. Lennon Fishery Research Biologist Appalachian Sport) BiblioKiMpliy : p. ]!. 1. Electric meters. 2. Water--Analysis. 3. Electric fishing. I. Title. ( Series

140

Metered Mail Form Domestic Mail Only  

E-Print Network [OSTI]

Metered Mail Form Domestic Mail Only For USPS Mail Only Charge to Department First Class Mail Media Meter Form. · All outgoing USPS Mail that needs postage should be kept separate from all other mail already be sealed prior to being metered. Failure to properly seal this type of mail could result

Palmeri, Thomas

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Smart Meter Security Infrastructure: Some Observations  

E-Print Network [OSTI]

to infer otherwise-private life-style details of the Smart Meter user. 2 An attacker who can issue on the capa- bility of the device, such an attacker can reset a Smart Meter, cut off electricity supply, access Smart Grid nodes via the Smart Meter, or pretend electricity use that is other than the actual use

Ladkin, Peter B.

142

Polish - American Heritage, Italian - American Heritage, German...  

Broader source: Energy.gov (indexed) [DOE]

Polish - American Heritage, Italian - American Heritage, German - American Heritage Months Polish - American Heritage, Italian - American Heritage, German - American Heritage...

143

Melodic cues to meter 1 Running Head: MELODIC CUES TO METER  

E-Print Network [OSTI]

Melodic cues to meter 1 Running Head: MELODIC CUES TO METER The Role of Melodic and Temporal Cues in Perceiving Musical Meter Erin E. Hannon Cornell University Joel S. Snyder Cornell University Tuomas Eerola-569-4326 Tel: 905-828-5415 E-mail: eeh5@cornell.edu #12;Melodic cues to meter 2 Abstract A number of different

Ahmad, Sajjad

144

ANALYSIS OF HIGH PRESSURE TESTS ON WET GAS FLOW METERING WITH A VENTURI METER  

E-Print Network [OSTI]

ANALYSIS OF HIGH PRESSURE TESTS ON WET GAS FLOW METERING WITH A VENTURI METER P. Gajan , Q, 64018 Pau cedex, France pierre.gajan@onera.fr Abstract This work deals with the flow metering of wet gas on the CEESI facilities are presented. They are performed at 75 bars with 0.6 beta ratio Venturi meter

145

PQMII POWER QUALITY METER INSTRUCTION MANUAL 11 PQMII Power Quality Meter  

E-Print Network [OSTI]

#12;#12;#12;PQMII POWER QUALITY METER ­ INSTRUCTION MANUAL 1­1 PQMII Power Quality Meter Chapter 1 Multilin PQMII Power Quality Meter is an ideal choice for continuous monitoring of a single or three-phase system. It provides metering for current, voltage, real power, reactive power, apparent power, energy use

Meyers, Steven D.

146

Ramp meters on trial: Evidence from the Twin Cities metering holiday  

E-Print Network [OSTI]

Ramp meters on trial: Evidence from the Twin Cities metering holiday David Levinson a,*, Lei Zhang; accepted 15 December 2004 Abstract Ramp meters in the Twin Cities have been the subject of a recent test metering for several representative freeways during the afternoon peak period. Seven performance measures

Levinson, David M.

147

2,275 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,275 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METERS NYLON STIFFENER 3/4" SAS .5 M 1/2" CHAIN 3" GLASS BALL FLOATS on 2.5 M Chain ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 5/8" SAS 2 METER CHAIN 697.4 METERS 7/16" WIRE ROPE SONTEK7 METERS 10 METERS 8.3 METERS TV

148

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METERS NYLON STIFFENER 3/4" SAS .5 M 1/2" CHAIN 5 SPLICE 6 ea.17" GLASS BALL FLOATS ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 5/8" SAS 2 METER CHAIN TC INVERTED5 METERS 697.4 METERS WIRE ROPE SONTEK7 METERS 10 METERS 8

149

Kansas - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Kansas - Net Metering Kansas - Net Metering Kansas - Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Kansas Program Type Net Metering Provider Kansas Corporation Commission Kansas adopted the Net Metering and Easy Connection Act in May 2009 (see K.S.A. 66-1263 through 66-1271), establishing net metering for customers of investor-owned utilities in Kansas. Net metering applies to systems that generate electricity using solar, wind, methane, biomass or hydro resources, and to fuel cells using hydrogen produced by an eligible

150

Progress Energy - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Progress Energy - Net Metering Progress Energy - Net Metering Progress Energy - Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State South Carolina Program Type Net Metering Provider Progress Energy Carolinas In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulated electric utilities; the order incorporates a net metering settlement signed by the individual interveners, the Office of Regulatory Staff and the three investor-owned utilities (IOUs). The order detailed the terms of net metering, including ownership of RECs, in South Carolina and standardized

151

Net Metering Webinar | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Webinar Net Metering Webinar Net Metering Webinar June 25, 2014 11:00AM MDT Attendees will become familiar with the services provided by utility net metering and their importance in making projects cost-effective. The speakers will provide information based on case histories of how facilities that generate their own electricity from renewable energy sources can feed electricity they do not use back into the grid. Many states have net-metering laws with which utilities must comply. In states without such legislation, utilities may offer net-metering programs voluntarily or as a result of regulatory decisions. The webinar will cover the general differences between states' legislation and implementation and how the net-metering benefits can vary widely for facilities in different areas of

152

Duke Energy - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Duke Energy - Net Metering Duke Energy - Net Metering Duke Energy - Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State South Carolina Program Type Net Metering In August 2009, the South Carolina Public Service Commission issued an [http://dms.psc.sc.gov/pdf/matters/F05030FC-E19A-9225-B838F72EDF4557DC.pdf] order mandating net metering be made available by the regulating utilities; the order incorporates a net metering settlement signed by the individual interveners, the Office of Regulatory Staff and the three investor-owned utilities (IOUs). The order detailed the terms of net metering, including

153

EPAct 2005 Metering Guidance Overview | Department of Energy  

Energy Savers [EERE]

EPAct 2005 Metering Guidance Overview EPAct 2005 Metering Guidance Overview Presentation covers an overview of the EPAct 2005 Metering Guidance and is given at the FUPWG 2006...

154

Widget:GoalMeter | Open Energy Information  

Open Energy Info (EERE)

GoalMeter GoalMeter Jump to: navigation, search This widget produces an image showing progress against some numeric goal. Parameters Parameter Type Required? Example Description goal Integer Y 100 Total goal value http_link String Y groups.google.com/group/openei URL to which the meter will hyperlink. Note that the leading "http://" must be omitted. title String Y Google Group Members The goal's title. value Integer Y 25 Current value of progress against the goal. height Integer N (default=100) 150 Height of the meter image (in pixels). width Integer N (default=200) 300 Width of the meter image (in pixels). Example Output Google Group Members (goal: 100) Retrieved from "http://en.openei.org/w/index.php?title=Widget:GoalMeter&oldid=271157"

155

Guam - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Guam - Net Metering Guam - Net Metering Guam - Net Metering < Back Eligibility Agricultural Commercial Industrial Institutional Nonprofit Residential Schools Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Wind Solar Home Weatherization Program Info Program Type Net Metering Provider Guam Energy Office Guam's Public Utilities Commission (PUC) reviewed net metering and interconnection during a regular meeting in February 2009 (Docket 08-10). Please contact the [http://www.guampuc.com/ Guam PUC] for the results of that docket review. In 2004, Guam enacted legislation requiring the Guam Power Authority (GPA) to allow net metering for customers with fuel cells, microturbines, wind energy, biomass, hydroelectric, solar energy or hybrid systems of these

156

Net Metering Rules (Arkansas) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Rules (Arkansas) Net Metering Rules (Arkansas) Net Metering Rules (Arkansas) < Back Eligibility Commercial Industrial Installer/Contractor Investor-Owned Utility Retail Supplier Rural Electric Cooperative Systems Integrator Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Arkansas Program Type Net Metering Provider Arkansas Public Service Commission The Net Metering Rules are promulgated under the authority of the Arkansas Public Service Commission. These rules are created to establish rules for net energy metering and interconnection. These rules are developed pursuant to the Arkansas Renewable Energy Development Act (Arkansas Code Annotated 23-18-603). These rules apply to all electric utilities.

157

A Million Meter Milestone | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

A Million Meter Milestone A Million Meter Milestone A Million Meter Milestone March 4, 2011 - 2:36pm Addthis To see what installing the 1 millionth meter looked like, check out this video. Don Macdonald Program Manager, Smart Grid Investment Grant Program What does this mean for me? Smart meters allow consumers to take personal control and ownership of her energy usage in a way not possible before. As program manager for the Department of Energy's Recovery Act funded Smart Grid Investment Grant (SGIG) program, I've had the pleasure of seeing SGIG reach several important milestones recently. Among the most notable has been the recent achievement of three million smart meters installed by SGIG recipients as of December 31, 2010. On February 23, 2011, along with my colleague Chris Irwin, I was in Houston, Texas where SGIG

158

SRP - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

SRP - Net Metering SRP - Net Metering SRP - Net Metering < Back Eligibility Commercial Residential Savings Category Buying & Making Electricity Solar Wind Program Info State Arizona Program Type Net Metering Provider SRP Salt River Project (SRP) modified an existing net-metering program for residential and commercial customers in November 2013. Net metering is now available to customers who generate electricity using photovoltaic (PV), geothermal, or wind systems up to 300 kilowatts (kW) in AC peak capacity. The kilowatt-hours (kWh) delivered to SRP are subtracted from the kWh delivered from SRP for each billing cycle. If the kWh calculation is net positive for the billing cycle, SRP will bill the net kWh to the customer under the applicable price plan, Standard Price Plan E-21, E-23, E-26,

159

Nonclassical dynamics induced by a quantum meter  

Science Journals Connector (OSTI)

Conventionally, the effect of measurements on a quantum system is assumed to introduce decoherence, which renders the system classical-like. We consider here a microscopic meter, that is, an auxiliary essentially quantum system whose state is measured repeatedly, and show that it can be employed to induce transitions from classical states into inherently quantumlike states. The meter state is assumed to be lost in the environment and we derive a non-Markovian master equation for the dynamic system in the case of nondemolition coupling to the meter; this equation can be cast in the form of an (Na)th-order differential equation in time, where Na is the dimension of the meter basis. We apply the approach to a harmonic oscillator coupled to a spin-12 meter and demonstrate how it can be used to engineer effective Hamiltonian evolution, subject to decoherence induced by the projective meter measurements.

J. Clausen; J. Salo; V. M. Akulin; S. Stenholm

2005-12-05T23:59:59.000Z

160

O&M Metering Guidance  

Broader source: Energy.gov (indexed) [DOE]

O&M and Metering Guidance O&M and Metering Guidance Ab Ream Ab.ream@ee.doe.gov Federal Utility Partnership Working Group October 2010, Rapid City SD 2 | FEDERAL ENERGY MANAGEMENT PROGRAM femp.energy.gov O&M and Metering Guidance FEMP Mission Statement "The Federal Energy Management Program facilitates the Federal government's implementation of sound, cost- effective energy management practices to enhance the nation's energy security and environmental stewardship" 3 | FEDERAL ENERGY MANAGEMENT PROGRAM femp.energy.gov O&M and Metering Guidance O&M Best Practice Guidance Release 3.0 - August 2010 General Updates Include:

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Ellsworth Air Force Base Advanced Metering Project  

Broader source: Energy.gov [DOE]

Presentation covers the Ellsworth Air Force Base Advanced Metering project and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

162

Advanced Metering Infrastructure Security Considerations | Department...  

Broader source: Energy.gov (indexed) [DOE]

Infrastructure Security Considerations The purpose of this report is to provide utilities implementing Advanced Metering Infrastructure (AMI) with the knowledge necessary to...

163

Assessment of Demand Response and Advanced Metering  

E-Print Network [OSTI]

#12;#12;2008 Assessment of Demand Response and Advanced Metering Staff Report Federal Energy metering penetration and potential peak load reduction from demand response have increased since 2006. Significant activity to promote demand response or to remove barriers to demand response occurred at the state

Tesfatsion, Leigh

164

Proton recoil scintillator neutron rem meter  

DOE Patents [OSTI]

A neutron rem meter utilizing proton recoil and thermal neutron scintillators to provide neutron detection and dose measurement. In using both fast scintillators and a thermal neutron scintillator the meter provides a wide range of sensitivity, uniform directional response, and uniform dose response. The scintillators output light to a photomultiplier tube that produces an electrical signal to an external neutron counter.

Olsher, Richard H. (Los Alamos, NM); Seagraves, David T. (Los Alamos, NM)

2003-01-01T23:59:59.000Z

165

Energy savings attributable to switching from master metering to individual metering of electricity  

SciTech Connect (OSTI)

This technical memo reviews and analyzes the published literature on electricity consumption by tenants in residential buildings with individual meters, compared with electricity consumption in residential buildings with master meters. An important finding is that energy savings of individual over master metering are strongly correlated with the price of electricity.

Nelson, S.H.

1981-01-01T23:59:59.000Z

166

Puerto Rico - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Puerto Rico - Net Metering Puerto Rico - Net Metering Puerto Rico - Net Metering < Back Eligibility Agricultural Commercial Industrial Institutional Local Government Multi-Family Residential Nonprofit Residential Schools State Government Savings Category Energy Sources Buying & Making Electricity Solar Wind Program Info Program Type Net Metering Provider Autoridad de Energía Electrica de Puerto Rico Puerto Rico enacted net-metering legislation in August 2007, allowing customers of Puerto Rico Electric Power Authority (PREPA) to use electricity generated by solar, wind or "other" renewable-energy resources to offset their electricity usage. This law applies to residential systems with a generating capacity of up to 25 kilowatts (kW) and non-residential systems up to one megawatt (MW) in capacity.*

167

Definition: Meter Communications Network | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Meter Communications Network Jump to: navigation, search Dictionary.png Meter Communications Network The communications infrastructure that supports two-way delivery of information between smart meters and data collectors or access points. This infrastructure can be wired or wireless, and can be owned by the utility or a third party service provider. This network is sometimes referred to as a "field area network".[1] Related Terms smart grid References ↑ https://www.smartgrid.gov/category/technology/meter_communications_network [[C Like Like You like this.Sign Up to see what your friends like. ategory: Smart Grid Definitions|Template:BASEPAGENAME]] Retrieved from "http://en.openei.org/w/index.php?title=Definition:Meter_Communications_Network&oldid=493063"

168

Energy Sub-Metering Equipment and Applications  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Sub-Metering Equipment and Applications Energy Sub-Metering Equipment and Applications Speaker(s): Sim Gurewitz Date: July 24, 2008 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Paul Mathew This talk will address the following topics:Submetering basics: What is it? How does a submeter work?How to obtain a finer level of energy information within the buildingApplications: Who submeters and why?LEED NC/EB/CS and submetering / Energy & Atmosphere pointsSubmetering equipment: gas, electric, water, steam, CW Btu and HHW BtuHow to install equipment without scheduling an outageLoad Control option for automated load shedding and peak shavingWireless submeters and communication options / integration to EMS-BMCSAutomatic remote meter reading and cost allocation softwarePutting it all together into a metering SYSTEM: read from anywhere, IP

169

Algorithms for revenue metering and their evaluation  

E-Print Network [OSTI]

systems, which include, among other functions, the remote measurement systems. The new generation of meters is capable of calculating almost any definition for the power components. The problem now is which definitions are going to be implemented...

Martinez-Lagunes, Rodrigo

2012-06-07T23:59:59.000Z

170

June 25 Webinar to Explore Net Metering  

Broader source: Energy.gov [DOE]

Register for the Net Metering webinar, which will be held on Wednesday, June 25, 2014, from 11 a.m. to 12:30 p.m. Mountain time.

171

Portable Liquid Flow Metering for Energy Conservation Programs  

E-Print Network [OSTI]

meters to measure liquids. This paper reviews the principles of ultrasonic flow meters. Applications and costs of ultrasonic versus orifice flow meters are important to consider in energy audits. A discussion follows on 'how' and 'where' to use...

Miles, F. J.

1982-01-01T23:59:59.000Z

172

Working With Your Utility to Obtain Metering Services  

Broader source: Energy.gov [DOE]

Presentationgiven at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meetingcovers the government metering requirement, the U.S. Department of Defense (DoD) metering directive, and customer metering services available from utilities.

173

You Can Justify Meters for Your Energy Conservation Program  

E-Print Network [OSTI]

Meters don't save energy' This statement has often concluded a meeting or terminated a budget request leaving the metering proponent feeling frustrated. Such a statement is technically correct when meters are evaluated in the same way as equipment...

Rusnak, J. J.

1981-01-01T23:59:59.000Z

174

Use Meters to Put Teeth into Your Conservation Programs  

E-Print Network [OSTI]

is effective flow metering, but that is a difficult job even in more traditional applications. The problem is compounded by the fact that traditional metering concepts are inadequate for the unique problems presented by retro-metering for in...

Hayes, J. W.; Rusnak, J. J.

1980-01-01T23:59:59.000Z

175

Property:Incentive/AggrCapLimit | Open Energy Information  

Open Energy Info (EERE)

AggrCapLimit AggrCapLimit Jump to: navigation, search Property Name Incentive/AggrCapLimit Property Type Text Description Aggregate Capacity Limit. Pages using the property "Incentive/AggrCapLimit" Showing 25 pages using this property. (previous 25) (next 25) A APS - Net Metering (Arizona) + 15 MW American Samoa - Net Metering (American Samoa) + 5% of utility's peak demand Ames Electric Department - Net Metering (Iowa) + Carried month to month at retail rate, granted to utility after 12 months Ashland Electric - Net Metering (Oregon) + No limit specified Aspen Electric - Net Metering (Colorado) + Credited to customer's next bill Austin Energy - Net Metering (Texas) + No limit specified (program will be re-evaluated after 1% of load is met) Avista Utilities - Net Metering (Idaho) + 0.1% of utility's peak demand in 1996 (in Idaho)

176

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METERS NYLON STIFFENER 3/4" SAS .5 M 1/2" CHAIN 5 SPLICE 17" GLASS BALL FLOATS 5/8" SAS 5/8" SAS 3 TON SWIVEL ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 5/8" SAS 2 METER CHAIN .5 METER CHAIN 3/4" SAS WITH BUSHING TC

177

Metering Best Practices: A Guide to Achieving Utility Resource Efficiency  

Broader source: Energy.gov [DOE]

Guide describes information about energy and resource metering at federal facilities, including metering requirements under the Energy Policy Act of 2005.

178

Demand Response and Smart Metering Policy Actions Since the Energy...  

Broader source: Energy.gov (indexed) [DOE]

Demand Response and Smart Metering Policy Actions Since the Energy Policy Act of 2005: A Summary for State Officials Demand Response and Smart Metering Policy Actions Since the...

179

Fuel Quality and Metering: Current Status and Future Needs |...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Fuel Quality and Metering: Current Status and Future Needs Fuel Quality and Metering: Current Status and Future Needs These slides were presented at the Onboard Storage Tank...

180

,,,,,"Capacity MW",,,,,"Number of Meters",,,,,"Energy Sold Back...  

U.S. Energy Information Administration (EIA) Indexed Site

Other",,,"All Technologies" ,,,,,"Capacity MW",,,,,"Number of Meters",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Number of Meters",,,,,"Energy Sold Back...

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Guidance for Electric Metering in Federal Buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

blank. blank. Executive Summary The Energy Policy Act of 2005 (EPAct 2005), Section 103, requires all federal agencies to install metering and advanced metering where found to be cost-effective, according to guidelines developed by the Department of Energy (DOE), in consultation with a number of interest groups. DOE has met with representatives from the metering industry, the utility industry, energy services industry, energy efficiency industry, energy effi- ciency advocacy organizations, national laboratories, universities, and federal facility managers to develop the guidelines set forth in this document. There were several areas in the language of Section 103 that required some level of clarification prior to finaliz- ing these guidelines, as follows: * DOE has determined that Section 103 pertains to

182

An Angstrom-long Meter Stick  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Physical Review Focus Physical Review Focus An Angstrom-long Meter Stick When you want to measure the width of a window frame or the height of your growing child, it helps to have a good meter stick. But on the atomic scale, accurate measurements are harder to come by. In the 17 July PRL, a team reports a potential new standard of length for short distances based on radiation from the excited nuclei of iron atoms. Further improvements may make this standard an important tool for probing the structure of matter, where physicists must gauge the separations between nuclei with an accuracy of millionths of an angstrom. Figure by Robert Irion depicting Mossbauer effect. by Robert Irion The meter, once defined as the gap between two etchings on a metal bar in Paris, is now set as the distance that light from a helium-neon laser

183

Liquid metal Flow Meter - Final Report  

SciTech Connect (OSTI)

Measuring the flow of liquid metal presents serious challenges. Current commercially-available flow meters use ultrasonic, electromagnetic, and other technologies to measure flow, but are inadequate for liquid metal flow measurement because of the high temperatures required by most liquid metals. As a result of the reactivity and high temperatures of most liquid metals, corrosion and leakage become very serious safety concerns. The purpose of this project is to develop a flow meter for Lockheed Martin that measures the flow rate of molten metal in a conduit.

Andersen C, Hoogendoom S, Hudson B, Prince J, Teichert K, Wood J, Chase K

2007-01-30T23:59:59.000Z

184

INSTRUCTION MANUAL digital pH/mV meter  

E-Print Network [OSTI]

INSTRUCTION MANUAL model 701A digital pH/mV meter /r^ ORION RESEARCH #12;contents Introduction 1 701A digital pH/mV meter is the ideal meter for all research and precision measurements with pH and chemical sensing electrodes. In both the absolute and relative mV modes, the meter covers a range of ± 1999

Kleinfeld, David

185

Laser Power Meter Large, bright, backlit LCD  

E-Print Network [OSTI]

Laser Power Meter FEATURES · Large, bright, backlit LCD display · Digital accuracy with analog-like movement for laser tuning · Works with thermopile and optical sensors · Intuitive button-driven user COMPATIBILITY · PowerMax® thermal sensors · Optical sensors FieldMaxII-TO Coherent Laser Measurement and Control

Woodall, Jerry M.

186

Monitoring Advanced Metering Infrastructures with Amilyzer  

E-Print Network [OSTI]

-way communications between smart meters and utility control centers. They are a key component of the smart grid mechanisms are part of communication standards such as the ANSI #12;C12.22. While those protective measures detecting intrusions in IT environments have been developed and evaluated. Through the Trustworthy Cyber

Sanders, William H.

187

KVP meter errors induced by plastic wrap  

SciTech Connect (OSTI)

The purpose of this study was to determine whether erroneous kVp meter readings, induced by plastic wrap, affected the actual kVp (output) of a dental X-ray machine. To evaluate the effect of plastic wrap on dental X-ray machine kVp meters, a radiation output device was used to measure output in mR/ma.s. An intraoral dental X-ray unit (S.S. White Model {number sign}90W) was used to make the exposures. First, the kVp meter was not covered with plastic wrap and output readings were recorded at various kVp settings with the milliamperage and time held constant. Secondly, the same kVp settings were selected before the plastic wrap was placed. Milliamperage and time were again held to the same constant. The X-ray console was then covered with plastic wrap prior to measuring the output for each kVp. The wrap possessed a static charge. This charge induced erroneous kVp meter readings. Out-put readings at the various induced kVp settings were then recorded. A kVp of 50 with no wrap present resulted in the same output as a kVp of 50 induced to read 40 or 60 kVp by the presence of wrap. Similar results were obtained at other kVp settings. This indicates that the plastic wrap influences only the kVp meter needle and not the actual kilovoltage of the X-ray machine. Dental X-ray machine operators should select kVp meter readings prior to placing plastic wrap and should not adjust initial settings if the meter is deflected later by the presence of wrap. The use of such a procedure will result in proper exposures, fewer retakes, and less patient radiation. If plastic wrap leads to consistent exposure errors, clinicians may wish to use a 0.5% sodium hypochlorite disinfectant as an alternative to the barrier technique.

Jefferies, D.; Morris, J.W.; White, V.P. (Southern Illinois Univ., Carbondale (USA))

1991-02-01T23:59:59.000Z

188

WRITTEN TESTIMONY OF WILLIAM F. BROGLIE  

E-Print Network [OSTI]

of the Northern Mariana Islands, the Republic of Palau, the Federated States of Micronesia, American Samoa

189

Upgrading of Traditional Electric Meter into Wireless Electric Meter Using ZigBee Technology  

Science Journals Connector (OSTI)

Since the electric generating, distributing and marketing has been possible; the Electric Meter was introduced and developed along the years, but never like this time. The digital technology, the wireless comm...

Berhanu Regassa; Ana Vernica Medina; Isabel M. Gmez; Octavio Rivera

2012-01-01T23:59:59.000Z

190

2010 Assessment of Demand Response and Advanced Metering - Staff Report |  

Broader source: Energy.gov (indexed) [DOE]

Assessment of Demand Response and Advanced Metering - Staff Assessment of Demand Response and Advanced Metering - Staff Report 2010 Assessment of Demand Response and Advanced Metering - Staff Report 2010 Assessment of Demand Response and Advanced Metering - Staff Report. The Federal Energy Regulatory Commission's 2010 Demand Response and Advanced Metering Survey (2010 FERC Survey, covering calendar year 2009) indicates that advanced metering penetration (i.e., the fraction of all installed meters that are advanced meters) reached approximately 8.7 percent in the United States, compared to approximately 4.7 percent in the 2008 FERC Survey (covering calendar year 2007). The upper Midwest, West and Texas have advanced meter penetrations exceeding 13 percent. As in previous surveys, electric cooperatives have the largest penetration, nearly 25 percent, among

191

2010 Assessment of Demand Response and Advanced Metering - Staff Report |  

Broader source: Energy.gov (indexed) [DOE]

2010 Assessment of Demand Response and Advanced Metering - Staff 2010 Assessment of Demand Response and Advanced Metering - Staff Report 2010 Assessment of Demand Response and Advanced Metering - Staff Report 2010 Assessment of Demand Response and Advanced Metering - Staff Report. The Federal Energy Regulatory Commission's 2010 Demand Response and Advanced Metering Survey (2010 FERC Survey, covering calendar year 2009) indicates that advanced metering penetration (i.e., the fraction of all installed meters that are advanced meters) reached approximately 8.7 percent in the United States, compared to approximately 4.7 percent in the 2008 FERC Survey (covering calendar year 2007). The upper Midwest, West and Texas have advanced meter penetrations exceeding 13 percent. As in previous surveys, electric cooperatives have the largest penetration, nearly 25 percent, among

192

Ellsworth Air Force Base Advanced Metering Project  

Broader source: Energy.gov (indexed) [DOE]

Ellsworth Air Force Base Ellsworth Air Force Base Advanced Metering Project A Partnership between Ellsworth AFB and MDU Resources Group, Inc. to install advanced metering on all large buildings on EAFB  Based in Bismarck, North Dakota  Celebrated our 85 th year in 2009  NYSE - MDU for over 60 years  Over $4B market cap  Fortune 500 Company  Member of the S&P MidCap 400 Index  Over 8,000 employees in 44 states  Business Lines:  Energy  Utility Resources  Construction Materials  Construction Materials  Energy  Oil and Gas Production  Utility Resources  Natural Gas Pipelines  Construction Services  Electric / Natural Gas Utilities  Utility Resources  Montana - Dakota Utilities Co.  Cascade Natural Gas Co.  Intermountain Gas Corporation

193

Resonant speed meter for gravitational wave detection  

E-Print Network [OSTI]

Gravitational-wave detectors have been well developed and operated with high sensitivity. However, they still suffer from mirror displacement noise. In this paper, we propose a resonant speed meter, as a displacement noise-canceled configuration based on a ring-shaped synchronous recycling interferometer. The remarkable feature of this interferometer is that, at certain frequencies, gravitational-wave signals are amplified, while displacement noises are not.

Atsushi Nishizawa; Seiji Kawamura; Masa-aki Sakagami

2008-05-01T23:59:59.000Z

194

Nevada Smart Meter Program Launches | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Nevada Smart Meter Program Launches Nevada Smart Meter Program Launches Nevada Smart Meter Program Launches October 18, 2010 - 11:30am Addthis Workers began installing smart meters for NV Energy's smart meter project three weeks ago. The project is expected to create 200 jobs, according to NV Energy. | Photo courtesy of NV Energy Workers began installing smart meters for NV Energy's smart meter project three weeks ago. The project is expected to create 200 jobs, according to NV Energy. | Photo courtesy of NV Energy Paul Lester Communications Specialist, Office of Energy Efficiency and Renewable Energy What does this mean for me? These meters will not only allow residents to lower their energy bills by providing them information on their energy use, but by reducing operating costs, the utility expects to pass on these savings as well.

195

City of St. George - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

City of St. George - Net Metering City of St. George - Net Metering City of St. George - Net Metering < Back Eligibility Commercial General Public/Consumer Residential Savings Category Solar Buying & Making Electricity Program Info State Utah Program Type Net Metering Provider City of St. George The St. George City Council adopted a [http://www.sgcity.org/wp/power/NetMeteringPolicy.pdf net-metering program for area utilities], including interconnection procedures, in October 2005.* The interconnection procedures include different requirements, based on system size, for systems up to 10 megawatts (MW). Net metering is available to residential and commercial customers that generate electricity using photovoltaic (PV) systems. The net metering agreements currently available on the utility's web site only pertain to

196

Two-Meter Temperature Surveys for Geothermal Exploration Project...  

Open Energy Info (EERE)

Two-Meter Temperature Surveys for Geothermal Exploration Project at NAS Fallon Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Two-Meter...

197

WINDExchange: Offshore 90-Meter Wind Maps and Wind Resource Potential  

Wind Powering America (EERE)

Offshore 90-Meter Wind Maps and Wind Resource Potential The U.S. Department of Energy provides 90-meter (m) height, high-resolution wind maps and estimates of the total offshore...

198

WINDExchange: Community-Scale 50-Meter Wind Maps  

Wind Powering America (EERE)

Community-Scale 50-Meter Wind Maps The U.S. Department of Energy provides 50-meter (m) height, high-resolution wind resource maps for most of the states and territories of Puerto...

199

WINDExchange: Residential-Scale 30-Meter Wind Maps  

Wind Powering America (EERE)

Residential-Scale 30-Meter Wind Maps The U.S. Department of Energy provides 30-meter (m) height, high-resolution wind resource maps for the United States. Businesses, farms, and...

200

Shared Signals: Using Existing Facility Meters for Energy Savings Verification  

E-Print Network [OSTI]

energy conservation projects. (2) These guidelines provide monitoring and verification options that have different levels of accuracy and cost. They are specifically designed for energy savings performance contracts and are designed to provide... with a fair degree of accuracy. The costs of using existing meters are often not as clear. Obviously, if an existing meter is used, the costs of purchasing new metering equipment is avoided. However, using an existing meter is not free of costs...

McBride, J. R.; Bohmer, C. J.; Price, S. D.; Carlson, K.; Lopez, J.

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

SmartD: smart meter data analytics dashboard  

Science Journals Connector (OSTI)

The ability of smart meters to communicate energy consumption data in (near) real-time enables data analytics for novel applications, such as pervasive demand response, personalized energy feedback, outage management, and theft detection. Smart meter ... Keywords: energy consumption analysis, smart meters, visualization

Aylin Jarrah Nezhad, Tri Kurniawan Wijaya, Matteo Vasirani, Karl Aberer

2014-06-01T23:59:59.000Z

202

RIS-M-2254 ON A RADIOCHROMIC DYE DOSE METER  

E-Print Network [OSTI]

RIS?-M-2254 ON A RADIOCHROMIC DYE DOSE METER Arne Miller and William L. McLaughlin Abstract. Radiochromic dye dose meters made of polyvinyl butyral (PVB) with hexa(hydroxyethyl)pararosaniline cyanide (HPR results and outlines plans for further research on this dose meter. Currently the response is found

203

ONE GEV BEAM ACCELERATION IN A ONE METER LONG  

E-Print Network [OSTI]

ONE GEV BEAM ACCELERATION IN A ONE METER LONG PLASMA CELL A Proposal to the Stanford Linear. A single SLC bunch is used to both induce wakefields in the one meter long plasma and to witness that are needed to apply high-gradient plasma wakefield acceleration to large scale accelerators. The one meter

204

Model 1918-C Hand-held Optical Meter  

E-Print Network [OSTI]

Model 1918-C Hand-held Optical Meter Start Up Guide #12;Start Up Guide 1 First printing 2006 © 2006, including safety precautions and start up procedures, needed to get your new optical meter up and running the use and operation of the optical meter is included in the complete User's Manual. The complete User

Kleinfeld, David

205

Math for Poets and Drummers The Mathematics of Meter  

E-Print Network [OSTI]

Math for Poets and Drummers The Mathematics of Meter Rachel Hall Saint Joseph's University 5600 a number of problems that are explored in class. In English and Spanish, the rhythm, or meter, of a piece- speare are written in the meter called iambic pentameter: five pairs of alternating unstressed

Hall, Rachel W.

206

Arnold Schwarzenegger TIME-OF-USE WATER METER EFFECTS  

E-Print Network [OSTI]

Arnold Schwarzenegger Governor TIME-OF-USE WATER METER EFFECTS ON CUSTOMER WATER USE; Master Meter Ed Amelung; Southern California Edison Company ­ Matt Garcia, Curtis DeWoody, and James · Transportation TimeofUse Water Meter Impacts on Customer Water Use is the final report for the project 500 07022

207

Weak measurements with a qubit meter  

E-Print Network [OSTI]

We derive schemes to measure the so-called weak values of quantum system observables by coupling of the system to a qubit meter system. We highlight, in particular, the meaning of the imaginary part of the weak values, and show how it can be measured directly on equal footing with the real part of the weak value. We present compact expressions for the weak value of single qubit observables and of product observables on qubit pairs. Experimental studies of the results are suggested with cold trapped ions.

Shengjun Wu; Klaus Mlmer

2009-11-13T23:59:59.000Z

208

THE USE OF GROUND-PENETRATING RADAR FOR ARCHAEOLOGY: DETERMINING SITE FORMATION PROCESSES AND SUBSURFACE FEATURES ON TUTUILA ISLAND, AMERICAN SAMOA  

E-Print Network [OSTI]

, ceremonial mound (i.e. star mound) construction details were easily seen in radar profiles. Ground penetrating radar has the potential to yield significant details about such mounds, with no physical impact to the site....

Welch, Daniel

2006-07-11T23:59:59.000Z

209

The lithics of Aganoa Village (AS-22-43), American Samoa: a test of chemical characterization and sourcing Tutuilan tool-stone  

E-Print Network [OSTI]

as the primary form of transportation. Basalt samples were tested for their geochemical composition using Instrumental Neutron Activation Analysis (INAA) and the results are compared to those of a similar study of quarries on the eastern portion of Tutuila...-43) was analyzed macroscopically, and a sample of it was analyzed using Instrumental Neutron Activation Analysis (INAA). Initial analysis included the use of current typologies for adzes and flake tools (Green and Davidson 1969; Clark and Herdrich 1993). All...

Crews, Christopher Thomas

2008-10-10T23:59:59.000Z

210

Long Island Power Authority - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Long Island Power Authority - Net Metering < Back Eligibility Agricultural Commercial Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Wind Solar Program Info State New York Program Type Net Metering Provider Long Island Power Authority : Note: In October 2012 the LIPA Board of Trustees adopted changes to the utility's net metering tariff that permit remote net metering for non-residential solar and wind energy systems, and farm-based biogas and wind energy systems. It also adopted a measure to increase the aggregate net metering cap for solar, agricultural biogas, residential micro-CHP and

211

Rocky Mountain Power - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Rocky Mountain Power - Net Metering Rocky Mountain Power - Net Metering Rocky Mountain Power - Net Metering < Back Eligibility Agricultural Commercial Fed. Government Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Idaho Program Type Net Metering Provider Rocky Mountain Power Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has a net-metering tariff on file with the Idaho Public Utilities Commission (PUC). The framework of the utilities' net-metering programs is similar, in that each utility: (1) offers net

212

Austin Energy - Net Metering (Texas) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Austin Energy - Net Metering (Texas) Austin Energy - Net Metering (Texas) Austin Energy - Net Metering (Texas) < Back Eligibility Commercial Savings Category Bioenergy Buying & Making Electricity Solar Home Weatherization Water Wind Program Info State Texas Program Type Net Metering Provider Austin Energy Austin Energy, the municipal utility of Austin Texas, offers net metering for renewable energy systems up to 20 kilowatts (kW) to its non-residential retail electricity customers. The definition of renewable includes solar*, wind, geothermal, hydroelectric, wave and tidal energy, biomass, and biomass-based waste products, including landfill gas. Systems must be used primarily to offset a portion or all of a customer's on-site electric load. Metering is accomplished using a single meter capable of registering the

213

Montana Electric Cooperatives - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Electric Cooperatives - Net Metering Electric Cooperatives - Net Metering Montana Electric Cooperatives - Net Metering < Back Eligibility Commercial Residential Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Home Weatherization Wind Program Info State Montana Program Type Net Metering Provider Montana Electric Cooperatives' Association The Montana Electric Cooperatives' Association (MECA) adopted model interconnection guidelines in 2001 and a revised net-metering policy in September 2008. Net metering is available in whole or part by most of the 26 electric cooperatives in Montana. A map of the service areas of each of member cooperative is available on the MECA web site. To determine if a specific cooperative offers net metering, view the MECA

214

Definition: Meter Data Management System | Open Energy Information  

Open Energy Info (EERE)

System System Jump to: navigation, search Dictionary.png Meter Data Management System A meter data management system (MDMS) collects and stores meter data from a head-end system and processes that meter data into information that can be used by other utility applications including billing, customer information systems, and outage management systems. The MDMS is a key resource for managing large quantities of meter data.[1] Related Terms system, outage management system References ↑ https://www.smartgrid.gov/category/technology/meter_data_management_system [[Ca LikeLike UnlikeLike You like this.Sign Up to see what your friends like. tegory: Smart Grid Definitionssmart grid,smart grid, |Template:BASEPAGENAME]]smart grid,smart grid, Retrieved from "http://en.openei.org/w/index.php?title=Definition:Meter_Data_Management_System&oldid=50258

215

Washington City Power - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Washington City Power - Net Metering Washington City Power - Net Metering Washington City Power - Net Metering < Back Eligibility General Public/Consumer Savings Category Solar Buying & Making Electricity Wind Program Info State Utah Program Type Net Metering Provider Washington City Washington City adopted a net-metering program, including interconnection procedures, in January 2008.* Net metering is available to residential and commercial customers that generate electricity using photovoltaic (PV) systems or wind-energy systems up to 10 kilowatts (kW) in capacity. At the customer's expense, the municipal utility will provide a single, bidirectional meter to measure the in-flow and out-flow of electricity at the customer's home. Systems are restricted to being sized to provide no more than 120% of the historic maximum monthly energy consumption of the

216

Farmington Electric Utility System - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Farmington Electric Utility System - Net Metering Farmington Electric Utility System - Net Metering Farmington Electric Utility System - Net Metering < Back Eligibility Residential Savings Category Energy Sources Buying & Making Electricity Solar Home Weatherization Water Wind Program Info State New Mexico Program Type Net Metering Provider Farmington Electric Utility System Net metering rules developed by the New Mexico Public Regulation Commission (PRC) apply to the state's investor-owned utilities and electric cooperatives. Municipal utilities, which are not regulated by the commission, are exempt from the PRC rules but authorized to develop their own net metering programs. Farmington Electric, a municipal utility, offers net metering to residential customers with systems up to 10 kilowatts (kW) in capacity.

217

Smart Metering Pilot Program Inc SMPPI | Open Energy Information  

Open Energy Info (EERE)

Metering Pilot Program Inc SMPPI Metering Pilot Program Inc SMPPI Jump to: navigation, search Name Smart Metering Pilot Program, Inc. (SMPPI) Place Washington, DC Product SMPPI is a non-profit corporation composed of representatives of Pepco, the D.C. Public Service Commission, the D.C. Office of People's Counsel, the D.C. Consumer Utility Board, and the International Brotherhood of Electrical Workers Local 1900. References Smart Metering Pilot Program, Inc. (SMPPI)[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Smart Metering Pilot Program, Inc. (SMPPI) is a company located in Washington, DC . References ↑ "Smart Metering Pilot Program, Inc. (SMPPI)" Retrieved from "http://en.openei.org/w/index.php?title=Smart_Metering_Pilot_Program_Inc_SMPPI&oldid=351192"

218

Smart Meters Offer 'Instant Gratification;' Help Houston Homeowners  

Broader source: Energy.gov (indexed) [DOE]

Meters Offer 'Instant Gratification;' Help Houston Meters Offer 'Instant Gratification;' Help Houston Homeowners Save Smart Meters Offer 'Instant Gratification;' Help Houston Homeowners Save July 1, 2011 - 12:15pm Addthis Houston resident Ruth Diorio explains to KPRC Local 2 News how much she's saved with her recently installed smart meter, which allows her to see her savings in real time. Houston resident Ruth Diorio explains to KPRC Local 2 News how much she's saved with her recently installed smart meter, which allows her to see her savings in real time. Liisa O'Neill Liisa O'Neill Former New Media Specialist, Office of Public Affairs What does this mean for me? Smart meters offer real time information on your energy use, which can help you lower your electricity bill. "Instant gratification" from a smart meter? So raves Houston homeowner Ruth

219

Scotia Energy Electricity - Net Metering Program (Nova Scotia, Canada) |  

Broader source: Energy.gov (indexed) [DOE]

Scotia Energy Electricity - Net Metering Program (Nova Scotia, Scotia Energy Electricity - Net Metering Program (Nova Scotia, Canada) Scotia Energy Electricity - Net Metering Program (Nova Scotia, Canada) < Back Eligibility Agricultural Commercial Industrial Low-Income Residential Multi-Family Residential Residential Schools Savings Category Water Buying & Making Electricity Home Weatherization Solar Wind Program Info State Nova Scotia Program Type Net Metering Provider Nova Scotia Power, Inc Nova Scotia Power Inc. Net Metering allows residential and commercial customers to connect small, renewable energy generating units to the provincial power grid. Generating units that produce renewable energy such as wind, solar, small hydro or biomass can be added to homes or businesses with the addition of a bi-directional meter. This meter monitors the electricity generated by the

220

SCE&G - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

SCE&G - Net Metering SCE&G - Net Metering SCE&G - Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State South Carolina Program Type Net Metering In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulated electric utilities; the order incorporates a net metering settlement signed by the individual interveners, the Office of Regulatory Staff and the three investor-owned utilities (IOUs). The order detailed the terms of net metering, including ownership of RECs, in South Carolina and standardized

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

E-Print Network 3.0 - automatic survey meter Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

management services such as fine grained pricing schemes, automatic meter reading, demand response... to demand measurement and billing. Meters supporting automatic meter reading...

222

E-Print Network 3.0 - automatic meter reading Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

fine grained pricing schemes, automatic meter reading, demand response... to demand measurement and billing. Meters supporting automatic meter reading (AMR) can report demand......

223

High Performance Computing Data Center Metering Protocol  

Broader source: Energy.gov (indexed) [DOE]

High Performance High Performance Computing Data Center Metering Protocol Prepared for: U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Federal Energy Management Program Prepared by: Thomas Wenning Michael MacDonald Oak Ridge National Laboratory September 2010 ii Introduction Data centers in general are continually using more compact and energy intensive central processing units, but the total number and size of data centers continues to increase to meet progressive computing requirements. In addition, efforts are underway to consolidate smaller data centers across the country. This consolidation is resulting in a growth of high-performance computing facilities (i.e. - supercomputers) which consume large amounts of energy to support the numerically intensive

224

Secretary Chu's Message about Forrestal Electric Metering  

Broader source: Energy.gov (indexed) [DOE]

0 0 Dear Colleagues, The Department of Energy has a responsibility and an opportunity to lead by example in promoting sustainable energy practices. As many of you have heard me say, energy efficiency is one of our best and most immediate opportunities to save energy, cut utility bills and decrease carbon pollution. I want to thank you for the steps many of you have already taken to reduce energy consumption. Today, I'm asking all employees at the Forrestal Building to take these efforts to the next level by participating in a competition to save money by saving energy. We recently divided the Forrestal complex into five zones and installed electric meters to measure the daily electricity consumption of overhead lights and power outlets in each zone. You've probably seen

225

ARRA Program Celebrates Milestone 600,000 Smart Meter Installations |  

Broader source: Energy.gov (indexed) [DOE]

ARRA Program Celebrates Milestone 600,000 Smart Meter Installations ARRA Program Celebrates Milestone 600,000 Smart Meter Installations ARRA Program Celebrates Milestone 600,000 Smart Meter Installations April 17, 2012 - 3:09pm Addthis On April 11, 2012, DOE Recovery Act funding recipient Sacramento Municipal Utility District (SMUD) celebrated a major milestone in the development of a regional smart grid in California: the installation of over 600,000 smart meters. For the event, Congresswoman Doris Matsui (D-Sacramento) visited SMUD's customer service center and praised the program for implementing a system "that will be more efficient, more reliable, and better for consumers." SMUD's meter installations are nearly complete, with only a few thousand remaining. In addition to smart meters, SMUD's grid modernization efforts will include automated distribution systems, a

226

City of New Orleans - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

City of New Orleans - Net Metering City of New Orleans - Net Metering City of New Orleans - Net Metering < Back Eligibility Agricultural Commercial Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Wind Solar Home Weatherization Program Info State Louisiana Program Type Net Metering Provider City Council Utilities Regulatory Office In May 2007, the New Orleans City Council adopted net-metering rules that are similar to rules adopted by the Louisiana Public Service Commission (PSC) in November 2005. The City Council's rules require Entergy New Orleans, an investor-owned utility regulated by the city, to offer net metering to customers with systems that generate electricity using solar energy, wind energy, hydropower, geothermal or biomass resources. Fuel

227

The Need for Essential Consumer Protections: Smart metering proposals and  

Broader source: Energy.gov (indexed) [DOE]

metering metering proposals and the move to time-based pricing. August 2010 The Need for Essential Consumer Protections: Smart metering proposals and the move to time-based pricing. August 2010 There is widespread consensus that the U.S. distribution and transmission systems for vital electricity service need to be modernized and upgraded. This modernization has been recently promoted under the rubric of the Smart Grid. The Smart Grid vision has three primary parts: (1) new communication and digital sensors and automation capabilities for the distribution and transmission systems; (2) new digital metering systems for all customers; and (3) direct interfaces between the new metering systems and customers through inhome technologies. The Need for Essential Consumer Protections: Smart metering proposals and

228

SaskPower Net Metering (Saskatchewan, Canada) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

SaskPower Net Metering (Saskatchewan, Canada) SaskPower Net Metering (Saskatchewan, Canada) SaskPower Net Metering (Saskatchewan, Canada) < Back Eligibility Commercial Agricultural Industrial Residential Savings Category Solar Buying & Making Electricity Program Info Funding Source SaskPower State Saskatchewan Program Type Net Metering Provider SaskPower Residents, farms and businesses with approved Environmental Preferred Technologies of up to 100 kilowatts (kW) of nominal (nameplate) generating capacity can deliver their excess electricity to our electrical grid. SaskPower will pay a one-time rebate, equivalent to 20% of eligible costs to a maximum payment of $20,000, for an approved and grid interconnected net metering project. The Net Metering Rebate is available to SaskPower, Saskatoon Light and Power and City of Swift Current electricity customers

229

U.S. Virgin Islands - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

U.S. Virgin Islands - Net Metering U.S. Virgin Islands - Net Metering U.S. Virgin Islands - Net Metering < Back Eligibility Commercial Fed. Government Institutional Local Government Residential Schools State Government Tribal Government Savings Category Solar Buying & Making Electricity Wind Program Info Program Type Net Metering In February 2007, the U.S. Virgin Islands Public Services Commission approved a limited net-metering program for residential and commercial photovoltaic (PV), wind-energy or other renewable energy system up to 10 kilowatts (kW) in capacity. In July 2009, the legislature passed Act 7075 that raised the capacity limits to 20 kW for residential systems, 100 kW for commercial systems, and 500 kW for public (which includes government, schools, hospitals). The aggregate capacity limit of all net-metered systems is five megawatts

230

Murray City Power - Net Metering Pilot Program | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Murray City Power - Net Metering Pilot Program Murray City Power - Net Metering Pilot Program Murray City Power - Net Metering Pilot Program < Back Eligibility Commercial General Public/Consumer Residential Savings Category Solar Buying & Making Electricity Home Weatherization Water Wind Program Info State Utah Program Type Net Metering Provider Murray City Power Under a pilot program, Murray City Power offers net metering to customers that generate electricity using photovoltaic (PV), wind-electric or hydroelectric systems with a maximum capacity of 10 kilowatts (kW).* The utility will install and maintain a revenue meter capable of registering the bi-directional flow of electricity at the customer's facility. Any customer net excess generation (NEG) is carried over to the customer's next bill as a kilowatt-hour credit. Each April, any remaining NEG credits are

231

City of Brenham - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

City of Brenham - Net Metering City of Brenham - Net Metering City of Brenham - Net Metering < Back Eligibility Agricultural Commercial General Public/Consumer Industrial Institutional Nonprofit Residential Schools State Government Savings Category Bioenergy Wind Buying & Making Electricity Energy Sources Solar Program Info State Texas Program Type Net Metering Provider City of Brenham In September 2010, the City of Brenham passed an ordinance adopting net metering and interconnection procedures. Customer generators up to 10 megawatts (MW) are eligible to participate, although customer generators with systems 20 kilowatts (kW) or less are eligible for a separate rider and expedited interconnection. The utility will install and maintain a meter capable of measuring flow of electricity in both directions. Any net

232

Utility-Scale Smart Meter Deployments, Plans & Proposals  

Broader source: Energy.gov (indexed) [DOE]

edisonfoundation.net/IEE edisonfoundation.net/IEE Utility-Scale Smart Meter Deployments, Plans & Proposals April 2010 Utility State Target Number of Meters Notes Resources AEP 1 IN, KY, MI, OH, OK, TX, VA, WV 5,000,000 AEP plans on deploying smart meters to all customers within their service territory and have deployed 10,000 meters to customers in South Bend, IN, and are presently deploying another 700,000 to AEP-Texas customers. Timing for the remaining deployments will depend on specific conditions in each of the seven operating company subsidiaries. AEP Corporate Sustainability Report 2009 2 Allegheny Power MD, PA, WV 700,000 Allegheny launched pilots in Morgantown, WV and Urbana, MD to test smart meters and thermostats (1,140 meters installed). In PA, Act 129 (2008)

233

Test procedures help ensure accuracy of orifice meters  

SciTech Connect (OSTI)

Orifice meter measurement with a chart recorder has been a standard in the petroleum industry for years. The meter consists of the plate/tube and recorder, requires minimal maintenance and can accurately measure a wide range of flow rates. It must be routinely tested to ensure sustained accuracy. The orifice meter measures differential pressure, static pressure, and temperature. However, the accuracy of the measurement is only as good as the calibration devices used in the test. A typical meter test consists of meter calibration, orifice plate inspection, quality of gas tests, and documentation (test report) to verify the data. The paper describes 19 steps that a gas technician can follow to conduct a thorough meter test.

Fillman, C.R. [Coastal Flow Measurement, Inc., Houston, TX (United States)

1996-07-01T23:59:59.000Z

234

Discussion the Traceability of Quantity Value of Digital Watthour Meter  

Science Journals Connector (OSTI)

To resolve the traceability of quantity value and calibration of digital watt-hour meter, in this paper introduced working principium of digital electric power metering system briefly, and analyzed the main origin of error from the theory of digital watt-hour meter and its calibration device. This paper also proposed new verification method of digital watt-hour meter calibration device and project of digital watt-hour meter traceability of quantity value. The method is used in digital signal generator calibration. The traceability project is traceability to the national primary standard which is corresponding to the device using in the method. The project in this paper, which is figure out verification and traceability of quantity value from main origin of error, provides a reasonable approach to traceability of digital watt-hour meter and a useful reference to decriminalization of digital metrology. Meantime, the scheme provides strong technical support for construction of digital transformer substation and Smart Strong Grid.

Meng Xiangfu; Liu Yuchao; Wang Yuhua

2012-01-01T23:59:59.000Z

235

2,363 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,363 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO TOP OF 1" NYLON EYE INTO EYE SPLICE 20 METERS 1 1/8" NYLON 697.4 METERS 7/16" WIRE ROPE 35 METERS 40 METERS 700 METERS 3/4" SAS, Wrench tighten. ** 3/4" SAS WITH BUSHING, Wrench tighten. ** .5 METER 1/2" CHAIN

236

Basic DC Meter Design ECE 2100 Circuit Analysis Laboratory  

E-Print Network [OSTI]

Basic DC Meter Design ECE 2100 Circuit Analysis Laboratory updated 8 January 2008 Pre-Laboratory Assignment 1. Design an ammeter with full scale current IFS equal to 5 mA using a meter movement rated at 0.5 mA and 100 mV. 2. Design a voltmeter with a full scale voltage VFS equal to 10 V using the meter

Miller, Damon A.

237

Metering Best Practices: A Guide to Achieving Utility Resource...  

Broader source: Energy.gov (indexed) [DOE]

Policy Act of 2005. mbpg.pdf More Documents & Publications Operations & Maintenance Best Practices Guide: Chapter 8 Guidance for Electric Metering in Federal Buildings...

238

BELANGER, T. V., AND M. T. MONTGOMERY. Seepage meter errors  

Science Journals Connector (OSTI)

tor is applied, field test point estimates of seep- ..... Location, depth, and mean seepage rate for each meter in a transect across Indian River lagoon near.

2000-03-19T23:59:59.000Z

239

Maritime Electric- Net Metering (Prince Edward Island, Canada)  

Broader source: Energy.gov [DOE]

In December 2005 The Renewable Energy Act and associated Regulations came into effect. A Government policy objective incorporated in the Act was the introduction of net metering for...

240

A spectral light absorption meter for measurements in the sea  

Science Journals Connector (OSTI)

Dec 17, 1974 ... the measuring period, that the horizontal di- ... ance in the upper few meters at high solar ... area of the spherical collector and the ratio.

2000-01-04T23:59:59.000Z

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Stick-on Electricity Meter - Energy Innovation Portal  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Building Energy Efficiency Find More Like This Return to Search Stick-on Electricity Meter Lawrence Berkeley National Laboratory Contact LBL About This Technology Publications:...

242

Wavelength meter having single mode fiber optics multiplexed inputs  

DOE Patents [OSTI]

A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

Hackel, R.P.; Paris, R.D.; Feldman, M.

1993-02-23T23:59:59.000Z

243

Nevada Renewable Energy Application For Net Metering Customers...  

Open Energy Info (EERE)

Renewable Energy Application For Net Metering Customers Jump to: navigation, search OpenEI Reference LibraryAdd to library Form: Nevada Renewable Energy Application For Net...

244

The Intersection of Net Metering and Retail Choice: An Overview...  

Office of Environmental Management (EM)

five different theoretical models describing different ways competitive suppliers and utilities provide net metering options for their customers. They then provided case studies to...

245

The Need for Essential Consumer Protections: Smart metering proposals...  

Broader source: Energy.gov (indexed) [DOE]

Grid vision has three primary parts: (1) new communication and digital sensors and automation capabilities for the distribution and transmission systems; (2) new digital metering...

246

Wavelength meter having single mode fiber optics multiplexed inputs  

DOE Patents [OSTI]

A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

Hackel, Richard P. (Livermore, CA); Paris, Robert D. (San Ramon, CA); Feldman, Mark (Pleasanton, CA)

1993-01-01T23:59:59.000Z

247

2,349 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,349 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO 1" NYLON EYE INTO EYE SPLICE 697.4 METERS 7/16" WIRE ROPE 40 METERS 700 METERS 3/4" SAS, Wrench tighten. ** 3/4" SAS WITH BUSHING, Wrench tighten. ** .5 METER 1/2" CHAIN 5 TON SWIVEL INDUCTIVE CABLE BREAKOUT

248

Recent developments in orifice meter and flow conditioner research  

SciTech Connect (OSTI)

In 1969 concerns were raised regarding the validity of the orifice meter`s coefficient of discharge uncertainty. An effort to resolve these concerns resulted in an internationally supported research project which produced a new sharp-edged concentric orifice meter empirical database and coefficient of discharge equation. However, the new empirical database and coefficient of discharge equation did not account for all of the differences being encountered in orifice metering. And in 1986, as a derivative of the coefficient of discharge equation research, questions were raised regarding the influences of installation effects on the orifice meter`s coefficient of discharge. The 1986 EC research data indicated that the flow conditioner and straight pipe installation requirements of the flow measurement standards were inadequate to prevent biasing of the orifice meter`s coefficient of discharge by flow disturbances generated from upstream piping elements. Data generated from 1990 through 1993 by GRI sponsored SWRI and NIST research confirmed the original EC biasing and further identified differential pressure tap radial position sensitivity and velocity profile and swirl angle theory deficiencies. Current research is continuing to define installation effects influences and identify possible solutions.

LaNasa, P.J. [CPL and Associates, Houston, TX (United States)

1995-12-31T23:59:59.000Z

249

Multiphase pumps and flow meters avoid platform construction  

SciTech Connect (OSTI)

One of the newest wrinkles in efficiency in BP`s Eastern Trough Area Project (ETAP) is the system for moving multiphase oil, water and gas fluids from the Machar satellite field to the Marnock Central Processing Facility (CPF). Using water-turbine-driven multiphase pumps and multiphase flow meters, the system moves fluid with no need for a production platform. In addition, BP has designed the installation so it reduces and controls water coning, thereby increasing recoverable reserves. Both subsea multiphase booster stations (SMUBS) and meters grew out of extensive development work and experience at Framo Engineering AS (Framo) in multiphase meters and multiphase pump systems for subsea installation. Multiphase meter development began in 1990 and the first subsea multiphase meters were installed in the East Spar Project in Australia in 1996. By September 1998, the meters had been operating successfully for more than 1 year. A single multiphase meter installed in Marathon`s West Brae Project has also successfully operated for more than 1 year. Subsea meters for ETAP were installed and began operating in July 1998.

Elde, J.

1999-02-01T23:59:59.000Z

250

Energy Secretary Chu Announces Five Million Smart Meters Installed  

Broader source: Energy.gov (indexed) [DOE]

Announces Five Million Smart Meters Installed Announces Five Million Smart Meters Installed Nationwide as Part of Grid Modernization Effort Energy Secretary Chu Announces Five Million Smart Meters Installed Nationwide as Part of Grid Modernization Effort June 13, 2011 - 12:00am Addthis Washington, DC - At a White House Grid Modernization event today, U.S. Department of Energy Secretary Steven Chu announced that more than five million smart meters have been installed nationwide as part of Recovery Act-funded efforts to accelerate modernization of the Nation's electric grid. Smart meters will provide utility companies with greater information about how much electricity is being used throughout their service areas. They will also give consumers access to real-time information about their energy consumption, allowing them to make well-informed decisions about how

251

Grays Harbor PUD - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Grays Harbor PUD - Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State District of Columbia Program Type Net Metering Provider Grays Harbor PUD Grays Harbor PUD's net-metering program differs slightly from what is required by Washington state law in that Grays Harbor PUD reimburses customers for net excess generation (NEG), at the end of each year, at 50% of the utility's retail rate. State law allows utilities to require customers to surrender NEG to the utility, without reimbursement, at the end of a 12-month billing cycle. Grays Harbor PUD has voluntarily gone

252

Smart Meters Help Balance Energy Consumption at Solar Decathlon |  

Broader source: Energy.gov (indexed) [DOE]

Smart Meters Help Balance Energy Consumption at Solar Decathlon Smart Meters Help Balance Energy Consumption at Solar Decathlon Smart Meters Help Balance Energy Consumption at Solar Decathlon September 28, 2011 - 10:57am Addthis The Team Tidewater Virginia smart meter, as seen on opening day, indicates the team generated 5 kW hours of electricity in the first several hours of the competition. | Image courtesy of Lachlan Fletcher, Studio 18a The Team Tidewater Virginia smart meter, as seen on opening day, indicates the team generated 5 kW hours of electricity in the first several hours of the competition. | Image courtesy of Lachlan Fletcher, Studio 18a Liisa O'Neill Liisa O'Neill Former New Media Specialist, Office of Public Affairs Clouds, rain, thunderstorms... at Solar Decathlon Village? Oh my, you may say. But less-than-ideal weather conditions are no match for this year's

253

Smart Meter Company Boosting Production, Workforce | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Smart Meter Company Boosting Production, Workforce Smart Meter Company Boosting Production, Workforce Smart Meter Company Boosting Production, Workforce September 30, 2010 - 10:53am Addthis Kevin Craft What does this mean for me? This South Carolina company is producing enough smart meters to reduce annual electricity use by approximately 1.7 million megawatt hours Smart meters provide detailed data on energy usage to both utilities and consumers and is a key component of the Smart Grid. In 2009, Itron Inc.'s manufacturing facility in West Union, South Carolina was the third largest industrial employer in Oconee County. Then, the company used a $5.2 million 48C Advanced Manufacturing Tax Credit awarded via the Recovery Act to re-equip the facility and hired 420 additional employees. "Improving our production capacity allowed us to hire more employees, and

254

Smart Meter Company Boosting Production, Workforce | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Smart Meter Company Boosting Production, Workforce Smart Meter Company Boosting Production, Workforce Smart Meter Company Boosting Production, Workforce September 30, 2010 - 10:53am Addthis Kevin Craft What does this mean for me? This South Carolina company is producing enough smart meters to reduce annual electricity use by approximately 1.7 million megawatt hours Smart meters provide detailed data on energy usage to both utilities and consumers and is a key component of the Smart Grid. In 2009, Itron Inc.'s manufacturing facility in West Union, South Carolina was the third largest industrial employer in Oconee County. Then, the company used a $5.2 million 48C Advanced Manufacturing Tax Credit awarded via the Recovery Act to re-equip the facility and hired 420 additional employees. "Improving our production capacity allowed us to hire more employees, and

255

Smart Meters Help Balance Energy Consumption at Solar Decathlon |  

Broader source: Energy.gov (indexed) [DOE]

Smart Meters Help Balance Energy Consumption at Solar Decathlon Smart Meters Help Balance Energy Consumption at Solar Decathlon Smart Meters Help Balance Energy Consumption at Solar Decathlon September 28, 2011 - 10:57am Addthis The Team Tidewater Virginia smart meter, as seen on opening day, indicates the team generated 5 kW hours of electricity in the first several hours of the competition. | Image courtesy of Lachlan Fletcher, Studio 18a The Team Tidewater Virginia smart meter, as seen on opening day, indicates the team generated 5 kW hours of electricity in the first several hours of the competition. | Image courtesy of Lachlan Fletcher, Studio 18a Liisa O'Neill Liisa O'Neill Former New Media Specialist, Office of Public Affairs Clouds, rain, thunderstorms... at Solar Decathlon Village? Oh my, you may say. But less-than-ideal weather conditions are no match for this year's

256

Improvements in Shallow (Two-Meter) Temperature Measurements and Data  

Open Energy Info (EERE)

Improvements in Shallow (Two-Meter) Temperature Measurements and Data Improvements in Shallow (Two-Meter) Temperature Measurements and Data Interpretation Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Improvements in Shallow (Two-Meter) Temperature Measurements and Data Interpretation Abstract The Great Basin Center for Geothermal Energy has been working on improvements in shallow (two-meter) temperature surveys in two areas: overcoming limitations posed by difficult ground conditions with the use of a portable rock drill, and improvements in temperature measurements and interpretations Previous 2-meter temperature surveys conducted by the Great Basin Center for Geothermal Energy have been limited to areas that were not excessively rocky. This limitation has been overcome by the use of a

257

Secretary Chu Announces Two Million Smart Grid Meters Installed Nationwide  

Broader source: Energy.gov (indexed) [DOE]

Two Million Smart Grid Meters Installed Two Million Smart Grid Meters Installed Nationwide Secretary Chu Announces Two Million Smart Grid Meters Installed Nationwide August 31, 2010 - 12:00am Addthis Columbus, OH - At an event today at Battelle headquarters in Columbus, Ohio, U.S. Energy Secretary Steven Chu announced that two million smart grid meters have been installed across the country, helping to reduce energy costs for families and businesses. As a result of funding from the Recovery Act, smart grid technology is speeding the modernization of the nation's electrical grid, helping to reduce the amount of time needed to respond to energy disruptions and enable consumers to monitor their energy consumption and costs. So far, more than 180,000 smart meters have been installed in Ohio. "As a result of an unprecedented investment from the Recovery Act, smart

258

Smart Meters on Tap for Owasso, Oklahoma | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Meters on Tap for Owasso, Oklahoma Meters on Tap for Owasso, Oklahoma Smart Meters on Tap for Owasso, Oklahoma September 10, 2010 - 12:52pm Addthis Stephen Graff Former Writer & editor for Energy Empowers, EERE What does this mean for me? Recovery Act-funded smart meter pilot project will help residents lower utility bills. Smart meter installations help utility company respond quicker to power outages. Seeing real-time energy use could help cities save 10% of their annual energy consumption. Owasso, Oklahoma, known as the "city with no limits," is living up to its name with sustainability and energy. The evidence is everywhere. You can't visit the city's website -- or Facebook, Twitter and Flickr accounts, for that matter -- without noticing its robust recycling and composting program, water conversation focus or

259

Colorado Wind Resource at 50 Meters Above Ground Level  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Wind Resource at 50 Meters Above Ground Level Wind Resource at 50 Meters Above Ground Level Metadata also available as Metadata: Identification_Information Data_Quality_Information Spatial_Data_Organization_Information Spatial_Reference_Information Entity_and_Attribute_Information Distribution_Information Metadata_Reference_Information Identification_Information: Citation: Citation_Information: Originator: AWS TrueWind/NREL Publication_Date: December 2003 Title: Colorado Wind Resource at 50 Meters Above Ground Level Geospatial_Data_Presentation_Form: vector digital data Online_Linkage: Description: Abstract: Annual average wind resource potential for the state of Colorado,

260

Parity meter for charge qubits: an efficient quantum entangler  

E-Print Network [OSTI]

We propose a realization of a charge parity meter based on two double quantum dots alongside a quantum point contact. Such a device is a specific example of the general class of mesoscopic quadratic quantum measurement detectors previously investigated by Mao et al. [Phys. Rev. Lett. 93, 056803 (2004)]. Our setup accomplishes entangled state preparation by a current measurement alone, and allows the qubits to be effectively decoupled by pinching off the parity meter. Two applications of the parity meter are discussed: the measurement of Bell's inequality in charge qubits and the realization of a controlled NOT gate.

B. Trauzettel; A. N. Jordan; C. W. J. Beenakker; M. Buttiker

2006-04-26T23:59:59.000Z

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

How to Read Your Electric Meter | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Your Electric Meter Your Electric Meter How to Read Your Electric Meter July 2, 2012 - 8:21pm Addthis The difference between one month's reading and the next is the amount of energy units that have been used for that billing period. | Photo courtesy of Warren Gretz, NREL. The difference between one month's reading and the next is the amount of energy units that have been used for that billing period. | Photo courtesy of Warren Gretz, NREL. What are the key facts? The basic unit of measure of electric power is the Watt, and one thousand Watts are called a kilowatt. Your electric utility bills you by the kilowatt-hour -- the number of kilowatts you use per hour. When reading an electric meter, read and write down the numbers as shown on the dials from right to left. You may also wish to contact your local utility company for more

262

Nano-to-Meter-Scale Building, a Summary  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Nano-to-Meter-Scale Building, a Summary Nano-to-Meter-Scale Building, a Summary Speaker(s): Danijel Rebolj Date: December 18, 2009 - 12:00pm Location: 90-3122 Development of the core nanotechnologies and synthetic biology is leading to results that are extremely interesting for production of the buildings on the nano level, thus growing buildings on site from the nano into the meter range. Although areas like nanorobotics, programmable materials, and programmable cells are still considered to be speculative to some extent, their fast development encouraged us to start systematic research of new ways for modeling and construction of buildings using bio-nano-technologies. The main motivation, however, was the recognition that, if designed in a sustainable way, the new ways of nano-to-meter-scale

263

City of Danville - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Danville - Net Metering Danville - Net Metering City of Danville - Net Metering < Back Eligibility Commercial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Water Solar Program Info State Virginia Program Type Net Metering For a renewable fuel generator with a capacity of 25 kilowatts (kW) or less, a notification form shall be submitted at least 30 days prior to the date the customer intends to interconnect their renewable fuel generator to the Utility's facilities. Renewable fuel generators with capacity over 25 kW are required to submit forms no later than 60 days prior to planned interconnection. The Utility will review and determine whether the requirements for Interconnection have been met. More information on this

264

Smart Meters Helping Oklahoma Consumers Save Hundreds During Summer Heat |  

Broader source: Energy.gov (indexed) [DOE]

Smart Meters Helping Oklahoma Consumers Save Hundreds During Summer Smart Meters Helping Oklahoma Consumers Save Hundreds During Summer Heat Smart Meters Helping Oklahoma Consumers Save Hundreds During Summer Heat July 26, 2011 - 4:27pm Addthis Small business owner Steve Kaplan told ABC News’ “Show Me the Money” on Good Morning America that he's saving over $320 per month compared to last summer, which they calculated could result in $1,300 a year. Small business owner Steve Kaplan told ABC News' "Show Me the Money" on Good Morning America that he's saving over $320 per month compared to last summer, which they calculated could result in $1,300 a year. Liisa O'Neill Liisa O'Neill Former New Media Specialist, Office of Public Affairs What does this mean for me? Utility-provided meters give consumers real-time information on how

265

How to Read Your Electric Meter | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

How to Read Your Electric Meter How to Read Your Electric Meter How to Read Your Electric Meter July 2, 2012 - 8:21pm Addthis The difference between one month's reading and the next is the amount of energy units that have been used for that billing period. | Photo courtesy of Warren Gretz, NREL. The difference between one month's reading and the next is the amount of energy units that have been used for that billing period. | Photo courtesy of Warren Gretz, NREL. What are the key facts? The basic unit of measure of electric power is the Watt, and one thousand Watts are called a kilowatt. Your electric utility bills you by the kilowatt-hour -- the number of kilowatts you use per hour. When reading an electric meter, read and write down the numbers as shown on the dials from right to left.

266

Two Million Smart Meters and Counting | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Million Smart Meters and Counting Million Smart Meters and Counting Two Million Smart Meters and Counting August 31, 2010 - 6:02pm Addthis Elizabeth Meckes Elizabeth Meckes Director of User Experience & Digital Technologies, Office of Public Affairs What does this mean for me? Smart meter technology will help families and businesses cut their energy costs by reducing response time for energy disruptions and enabling consumers to better monitor their consumption. The implementation of smart grid technologies could reduce electricity use by more than four percent annually by 2030 -- that would mean consumers around the country would see savings of over $20 billion each year. Secretary Steven Chu visited Battelle headquarters in Columbus, Ohio, today to make a big announcement about our nation's electrical grid: an

267

Category:Smart Grid Projects - Advanced Metering Infrastructure | Open  

Open Energy Info (EERE)

Metering Infrastructure Metering Infrastructure Jump to: navigation, search Smart Grid Projects - Advanced Metering Infrastructure category Pages in category "Smart Grid Projects - Advanced Metering Infrastructure" The following 31 pages are in this category, out of 31 total. A ALLETE Inc., d/b/a Minnesota Power Smart Grid Project B Baltimore Gas and Electric Company Smart Grid Project Black Hills Power, Inc. Smart Grid Project Black Hills/Colorado Electric Utility Co. Smart Grid Project C CenterPoint Energy Smart Grid Project Central Maine Power Company Smart Grid Project Cheyenne Light, Fuel and Power Company Smart Grid Project City of Fulton, Missouri Smart Grid Project City of Glendale Water and Power Smart Grid Project City of Quincy, FL Smart Grid Project City of Westerville, OH Smart Grid Project

268

A continuous reading fluorescence meter for eddy diffusion studies  

E-Print Network [OSTI]

LIBRARY A AIS COLLEGE OF TEXAS A CONTINUOUS READINO FLUORESCENCE METER FOR EDDY DIFFUSION STUDIES BY Frank Wooten Moon, Jr. A Thesis Submitted to ths Qraduate Scbool of the Agricultural and Mechanical College oi' Texas in partial...

Moon, Frank Wooten

1956-01-01T23:59:59.000Z

269

Value creation and value capture of advanced electricity meter information  

E-Print Network [OSTI]

Advanced or smart metering has been a hot topic in the electricity community for several years. Despite the excitement about the technology, few business cases are actually able to justify the investment cost. One reason ...

Oesterlin, Ulf

2011-01-01T23:59:59.000Z

270

Radiofrequency fields associated with the Itron smart meter  

Science Journals Connector (OSTI)

......density enhancement factor of (1.6)2 or 2.56 for use in Equation (A1). REFERENCES 1 FERC. Assessment of Demand Response and Advanced Metering. (2008) Federal Energy Regulatory Commission. 2 FCC. Evaluating Compliance with FCC Guidelines......

R. A. Tell; G. G. Sias; A. Vazquez; J. Sahl; J. P. Turman; R. I. Kavet; G. Mezei

2012-08-01T23:59:59.000Z

271

25 years ago: the official farewell to the meter  

E-Print Network [OSTI]

On october 21st 1983 took place in S\\`evres on the western outskirts of Paris the official funeral of the meter. With it the notion of distance as a physical observable was buried.

Thomas Schucker

2008-10-20T23:59:59.000Z

272

LM to Meet Energy Metering Goals Through Enhanced Data Collection...  

Broader source: Energy.gov (indexed) [DOE]

usage and metering. The first goal states that LM should reduce energy use intensity (EUI) by 30 percent by fiscal year (FY) 2020, as compared to the FY 2003 baseline. The...

273

Metering and Calibration in LoanSTAR Buildings  

E-Print Network [OSTI]

or many stories away from each other. Power measurements across multiple panels can increase costs dramatically. Buildings often have multiple electrical feeds or feed additional buildings. Asbestos is found in many chilled and hot water piping... installed before 1970. Installation of thermal metering requires asbestos abatement. The cost to remove the asbestos may be too high to justify the thermal metering. (6) Timely installation of equipment requires an intensive coordination effort during...

O'Neal, D. L.; Bryant, J. A.; Turner, W. D.; Glass, M. G.

1990-01-01T23:59:59.000Z

274

Transportation and Electricity Convergence Session 2: National Lab Perspective (Sub-metering Hardware and Protocols)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transportation and Electricity Convergence Session 2: National Lab Perspective (Sub-metering Hardware and Protocols) 1912 2012 Theodore Bohn Argonne National Laboratory 4 th Annual Workshop Evs- Transportation and Electricity Convergence Houston, TX Nov 2, 2011 ANL Perspective: Standards are the common thread that enables interoperability of new technologies Detroit was the first American city to use electric taxi cabs, in 1914. Are Indoor/Outdoor Charge Ports New? Detroit's first electric taxi accumulated >46,000 miles first two years. 2 Outdoor Curb-Side Charging Port Indoor charging stations 3 Charging Levels/ Recharge Times (it depends)  AC Level 1 - 120 v/20A outlet (~1600W) - In most garages - Outlet capacity? - Dedicated outlet usually required

275

Baseline conditions for orifice meter calibration, Topical report, February 1990-July 1992  

SciTech Connect (OSTI)

The study analyzes nominal 102 mm (4') baseline orifice discharge coefficient, data for Beta ratios between 0.2 and 0.75 from several independent laboratories in the United States and Europe. Graphs of Cd vs. Reynolds number are presented for each data set, and each data set was analyzed to determine the statistical mean deviation and standard deviation from the American Gas Association (A.G.A.) Report No. 3 orifice coefficient equation. Baseline orifice Cd data taken in the Gas Research Institute Metering Research Facility (MRF) flowing nitrogen agree well with comparable high accuracy baseline data from the other laboratories. For Beta ratio values between 0.2 and 0.67, the mean deviation of MRF baseline data from the A.G.A. Report No. 3 orifice equation ranges from 0.05% to 0.20%. Vertical and horizontal profiles of mean axial velocity and axial turbulence intensity were measured in the MRF under typical baseline flow conditions for meter run lengths of 45 D and 100 D. The baseline profiles of mean axial velocity satisfy the International Standards Organization (ISO) 5167 requirement of less than + or - 5% variation from a fully developed, turbulent flow velocity profile.

Morrow, T.B.; Park, J.T.

1992-10-01T23:59:59.000Z

276

Modeling demand response and economic impact of advanced and smart metering  

Science Journals Connector (OSTI)

Advanced metering constitutes an essential component of communications between electricity suppliers and consumers. It may be possible to augment demand response by coupling Advanced Metering Infrastructure (AMI)...

Praneeth Aketi; Suvrajeet Sen

2014-09-01T23:59:59.000Z

277

Building a wireless mesh networked real-time electricity metering system in an MIT dormitory .  

E-Print Network [OSTI]

??A competitive, closed-loop information feedback system of wireless electricity meters was designed, tested, and implemented in seven MIT dormitory rooms. The meters utilized Allegro Hall (more)

Oehlerking, Austin L

2009-01-01T23:59:59.000Z

278

Smart Meters and a Smarter Grid | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Smart Meters and a Smarter Grid Smart Meters and a Smarter Grid Smart Meters and a Smarter Grid May 16, 2011 - 4:40pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory Have you heard of smart meters? Do you understand them? If so, you've had a leg up on me until now. I've heard of smart meters here and there from the odd news article or website, but to me the grapevine has been more like an invisible beehive: all buzz and no honey. Where are they? Why don't I have one yet, and will I have to buy it to be part of the system? Do they really save energy? Is Big Brother counting my kilowatts for me now, or what? These are the questions that don't keep me up at night, but I suspect more and more people are asking. Photo credit: U.S. Department of Energy We talked about what a Smart Grid is in February. The standard electrical

279

Compensated count-rate circuit for radiation survey meter  

DOE Patents [OSTI]

A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for counting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensated circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

Todd, Richard A. (Powell, TN)

1981-01-01T23:59:59.000Z

280

Compensated count-rate circuit for radiation survey meter  

DOE Patents [OSTI]

A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for couting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensation circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

Todd, R.A.

1980-05-12T23:59:59.000Z

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Smart Meter Investments Support Rural Economy in Arkansas  

Broader source: Energy.gov (indexed) [DOE]

Smart Meter Investments Support Rural Economy in Arkansas Smart Meter Investments Support Rural Economy in Arkansas Woodruff Electric Cooperative (Woodruff) serves customers in seven eastern Arkansas counties. The proportion of residents living in poverty in those counties is more than double the national average. As a member-owned rural electric cooperative, Woodruff is connected to its customers and engaged in economic development efforts to bring more jobs and higher incomes to local communities. In order to bring the capital investment and its accompanying economic benefits to the region without delay, Woodruff completed its project installation ahead of schedule. With a total budget of $5 million, funded partially with nearly $2.4 million in Recovery Act funding from the U.S. Department of Energy (DOE), Woodruff was able to install 14,450 smart meters and supporting

282

Smarter Meters Help Customers Budget Electric Service Costs  

Broader source: Energy.gov (indexed) [DOE]

Tri-State Smart Grid Investment Grant Tri-State Smart Grid Investment Grant 1 Tri-State's service area includes parts of Fannin County, Georgia; Polk County, Tennessee; and Cherokee County, North Carolina. Smarter Meters Help Customers Budget Electric Service Costs Tri-State Electric Membership Cooperative (Tri-State) is a distribution rural electric cooperative that primarily serves more than 12,000 rural customers, many of whom have low-incomes living at or near poverty level across a multi-state region (see map). Under their smart grid project, Tri-State has replaced conventional electromechanical meters with solid-state smart meters and implemented advanced electricity service programs in order to give customers greater control over their energy use and costs.

283

The Need for Essential Consumer Protections: Smart Metering Proposals and  

Broader source: Energy.gov (indexed) [DOE]

Metering Metering Proposals and the Move to Time-Based Pricing The Need for Essential Consumer Protections: Smart Metering Proposals and the Move to Time-Based Pricing There is a widespread consensus that the U.S. distribution and transmission systems for vital electricity service need to be modernized and upgraded to handle not only load growth, but the integration of renewable resources and the potential for a significant increase in electric-powered vehicles. This modernization has been recently promoted under the rubric of the Smart Grid. The Smart Grid vision has three primary parts: (1) new communication and digital sensors and automation capabilities for the distribution and transmission systems, designed to make the grid more reliable and capable of integrating renewable and local-level distribution

284

Cyprus Smart metering demo (Smart Grid Project) | Open Energy Information  

Open Energy Info (EERE)

Cyprus Smart metering demo (Smart Grid Project) Cyprus Smart metering demo (Smart Grid Project) Jump to: navigation, search Project Name Cyprus Smart metering demo Country Cyprus Coordinates 35.126411°, 33.429859° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":35.126411,"lon":33.429859,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

285

Working With Your Utility to Obtain Metering Services  

Broader source: Energy.gov (indexed) [DOE]

Dykes Dykes Federal Segment Mgr Georgia Power/Southern Company Wednesday, 22 May 2013 Federal Utility Partnership Working Group Spring 2013 - May 22-23 San Francisco, CA Hosted by: Pacific Gas and Electric Company  What is the Government Requirement ◦ New DoD Directive  What is Available from Your Serving Utility  Customer Metering Services  Issues to Consider  Conclusion 4.4 million customers 42,000+ MW 27,000 miles of transmission lines 3,700 substations 26,000 employees Other subsidiaries: Southern Linc, Southern Power, Southern Telecom, Southern Nuclear Retail Service Territory across 120,000 square miles  Section 103, EPAct 2005 - All Federal Agencies ◦ Meter electricity on all facilities 30,000 SqFt and larger ◦ Meter those facilities with significant energy usage

286

Microsoft Word - CLPUD Revenue Metering CX.doc  

Broader source: Energy.gov (indexed) [DOE]

Gregory Vassallo Gregory Vassallo TPC-ALVEY Proposed Action: New Revenue Meters at Central Lincoln's Florence and Berrydale Substations Budget Information: Work Order # 00004866, Task 04 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6 Additions or modifications to electric power transmission facilities that would not affect the environment beyond the previously developed facility... Location: Lane County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA plans to upgrade revenue metering at Central Lincoln People's Utility District's (Central Lincoln) Florence and Berrydale Substations to 115-kV. Bonneville will retire the 12.5-kV revenue metering at Central Lincoln's Florence, Berrydale, and Heceta Beach Substations once

287

Microsoft Word - CX -Lewis County PUD metering_.doc  

Broader source: Energy.gov (indexed) [DOE]

KEC-4 KEC-4 SUBJECT: Environmental Clearance Memorandum John Brank Project Manager - TPC-Olympia Proposed Action: Installation of metering equipment at existing facilities for power scheduling. Budget Information: Work order 00202861, Task 01 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6 Additions or modifications to electric power transmission facilities that would not affect the environment beyond the previously developed facility area... Location: Lewis County, Washington Proposed by: BPA Description of the Proposed Action: BPA proposes to install meter equipment at multiple locations in Lewis County, Washington. The project is needed as Lewis county PUD plans to become a BPA Slice customer and needs to obtain meter data at 5 minute intervals. The

288

American Goldfinch  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

American Goldfinch American Goldfinch Name: Mary-Ellen Location: N/A Country: N/A Date: N/A Question: I happened on an American Goldfinch in my yard last week who could not fly. I captured it and now have it living in a large box. I have been feeding it commericial wild finch seed, niger seed and some sunflower seed. I have also provided a small cup of fine sand and a dish of water. Am I missing anything in it's diet? I had hoped to find someone to take it and care for it until it could fly again but have been unsuccessful so I may end up caring for it. It's wing is not visibly injured, however it can only flutter. I have been caring for it for 6 days now and it appears OK. Have also provided it with a small perch (branch) which it seems to use most of the time. Any other suggestions?

289

Accuracy improved with analysis of pulsation effects at gas-pipeline metering facilities  

SciTech Connect (OSTI)

Results of recent research have provided means for diagnosing and controlling systems effects - pulsations and other adverse flow conditions at natural-gas metering sites. In recent years both in the U.S. and in the European Economic Community, several programs have been concerned with improving orifice coefficient data. Programs sponsored by the Gas Research Institute (GRI), the American Petroleum Institute (API), and the American Gas Association (AGA) at the National Bureau of Standards (NBS) facilities at Gaithersburg, MD., and Boulder, Colo., and at the Colorado Engineering Experiment Station are notable examples of this work. Parallel test work in the U.K. at British Gas and National Engineering Labs, at Gasunie in The Netherlands; and at Gaz de France have included round-robin comparison testing of a few standardized orifice sizes. In all cases, the primary objective has been substantially to extend the orifice data base, to reduce data scatter, and to define the seriousness of ''facility bias'' effects which appear to be inherent in the various individual test facilities.

Sparks, C.R.; McKee, R.J.

1986-12-08T23:59:59.000Z

290

Entropy Meters and the Entropy of Non-extensive Systems  

E-Print Network [OSTI]

In our derivation of the second law of thermodynamics from the relation of adiabatic accessibility of equilibrium states we stressed the importance of being able to scale a system's size without changing its intrinsic properties. This leaves open the question of defining the entropy of macroscopic, but unscalable systems, such as gravitating bodies or systems where surface effects are important. We show here how the problem can be overcome, in principle, with the aid of an `entropy meter'. An entropy meter can also be used to determine entropy functions for non-equilibrium states and mesoscopic systems.

Elliott H. Lieb; Jakob Yngvason

2014-03-30T23:59:59.000Z

291

Accurate 100:1 Rangeability Linear Response Head Meter  

E-Print Network [OSTI]

as regards its sensitivity to changes in density, ie; a change of 1% in density results in a metering error of 1/2%. The compensation equation is: mass flow Qm volumetric f 10\\'/Qv Additionally, factors such as vapor expansion and thermal expansion... as regards its sensitivity to changes in density, ie; a change of 1% in density results in a metering error of 1/2%. The compensation equation is: mass flow Qm volumetric f 10\\'/Qv Additionally, factors such as vapor expansion and thermal expansion...

Grant, G. H.

292

Commercial Buildings Partnership Projects - Metered Data Format and Delivery  

SciTech Connect (OSTI)

A number of the Commercial Building Partnership Projects (CBPs) will require metering, monitoring, data analysis and verification of savings after the retrofits are complete. Although monitoring and verification (M&V) agents are free to use any metering and monitoring devices that they chose, the data they collect should be reported to Pacific Northwest National Laboratory (PNNL) in a standard format. PNNL will store the data collected in its CBP database for further use by PNNL and U.S. Department of Energy. This document describes the data storage process and the deliver format of the data from the M&V agents.

Katipamula, Srinivas

2010-11-16T23:59:59.000Z

293

US Recovery Act Smart Grid Projects - Advanced Metering Infrastructure |  

Open Energy Info (EERE)

Projects - Advanced Metering Infrastructure Projects - Advanced Metering Infrastructure Jump to: navigation, search CSV Loading map... {"format":"googlemaps3","type":"ROADMAP","types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"limit":500,"offset":0,"link":"all","sort":[""],"order":[],"headers":"show","mainlabel":"","intro":"","outro":"","searchlabel":"\u2026 further results","default":"","geoservice":"google","zoom":false,"width":"600px","height":"350px","centre":false,"layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","icon":"","visitedicon":"","forceshow":true,"showtitle":true,"hidenamespace":false,"template":false,"title":"","label":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"locations":[{"text":"

294

Microwave Pickup on the Crawford Hill 7-meter Jeff McMahon  

E-Print Network [OSTI]

Microwave Pickup on the Crawford Hill 7-meter Telescope Jeff McMahon Project Advisor: Suzanne-Meter Telescope The Crawford Hill 7-meter telescope located at Bell labs in Holmdel, New Jersey is being considered for use in the CapMAP project. This antenna is a 7-meter offset Cassegrain reflector antenna

295

EVALUATING EFFECTIVENESS OF RAMP Evidence from the twin cities ramp meter shut-off  

E-Print Network [OSTI]

Chapter 9 EVALUATING EFFECTIVENESS OF RAMP METERS Evidence from the twin cities ramp meter shut-625-6354 Abstract: Ramp meters in the Twin Cities have been turned off for eight weeks in Fall 2000 in an experiment representative freeways during the afternoon peak period. Several performance measures for ramp metering

Levinson, David M.

296

Active fault creep variations at Chihshang, Taiwan, revealed by creep meter monitoring, 19982001  

E-Print Network [OSTI]

Active fault creep variations at Chihshang, Taiwan, revealed by creep meter monitoring, 1998] The daily creep meter data recorded at Chihshang in 1998­2001 are presented. The Chihshang creep meter similar annual shortening rates: 16.2 mm at the Tapo site (comprising two connected creep meters) and 15

Lee, Jian-Cheng

297

How to Read Residential Electric and Natural Gas Meters | Department of  

Broader source: Energy.gov (indexed) [DOE]

Residential Electric and Natural Gas Meters Residential Electric and Natural Gas Meters How to Read Residential Electric and Natural Gas Meters June 24, 2012 - 3:00pm Addthis An electromechanical electric meter on the side of a house. | Photo courtesy of ©iStockphoto/epantha An electromechanical electric meter on the side of a house. | Photo courtesy of ©iStockphoto/epantha A digital electric meter on the side of a house. | Photo courtesy of ©iStockphoto/nbehmans A digital electric meter on the side of a house. | Photo courtesy of ©iStockphoto/nbehmans A natural gas meter on a house. | Photo courtesy of ©iStockphoto/fstockfoto A natural gas meter on a house. | Photo courtesy of ©iStockphoto/fstockfoto An electromechanical electric meter on the side of a house. | Photo courtesy of ©iStockphoto/epantha

298

P\\procedure\\EU#7 Page 1 of 2 TITLE: PROCEDURE FOR RECORDING AND TRANSMITTING METER READINGS  

E-Print Network [OSTI]

P\\procedure\\EU#7 Page 1 of 2 TITLE: PROCEDURE FOR RECORDING AND TRANSMITTING METER READINGS FOR NEW METER SETS, METER REPLACEMENTS AND WHEN THE ACCOUNTABILITY FOR THE METERS USAGE CHANGES OBJECTIVE AND PURPOSE: To provide a timely and accurate method of capturing meter readings when a meter is changed out

Fernandez, Eduardo

299

1. From the Mail Services website, (www.princeton.edu/mail) click on Metered Mail to access the Meter Request Form.  

E-Print Network [OSTI]

1. From the Mail Services website, (www.princeton.edu/mail) click on Metered Mail to access the Meter Request Form. 2. Log in using your Princeton NetID and password. The system will pre the drop-down menu. To enter a new chartstring, click "Create New." Online Meter Request Form A step

Singh, Jaswinder Pal

300

Advanced computational simulation of flow phenomena associated with orifice meters  

SciTech Connect (OSTI)

This paper presents and discusses results from a series of computational fluid dynamics (CFD) simulations of fluid flow phenomena associated with orifice meters. These simulations were performed using a new, state-of-the-art CFD code developed at Southwest Research Institute. This code is based on new techniques designed to take advantage of parallel computers to increase computational performance and fidelity of simulation results. This algorithm uses a domain decomposition strategy to create grid systems for very complex geometries composed of simpler geometric subregions, allowing for the accurate representation of the fluid flow domain. The domain decomposition technique maps naturally to parallel computer architectures. Here, the concept of message-passing is used to create a parallel algorithm, using the Parallel Virtual Machine (PVM) library. This code is then used to simulate the flow through an orifice meter run consisting of an orifice with a beta ratio of 0.5 and air flowing at a Reynolds number of 91,100. The work discussed in this paper is but the first step in developing a Virtual Metering Research Facility to support research, analysis, and formulation of new standards for metering.

Freitas, C.J. [Southwest Research Inst., San Antonio, TX (United States)

1995-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Advanced accelerator simulation research: miniaturizing accelerators from kilometers to meters  

E-Print Network [OSTI]

Advanced accelerator simulation research: miniaturizing accelerators from kilometers to meters W: Advanced accelerator research is aimed at finding new technologies that can dramatically reduce the size and cost of future high-energy accelerators. Supercomputing is already playing a dramatic and critical role

Geddes, Cameron Guy Robinson

302

Multi-vendor Penetration Testing in the Advanced Metering Infrastructure  

E-Print Network [OSTI]

Infrastructure (AMI) is changing the way electric energy is produced, priced, and consumed. The introduction,mcdaniel}@cse.psu.edu Abstract - The advanced metering infrastructure (AMI) is revolutionizing electrical grids. Intelligent AMI we develop an archetypal attack tree approach to guide penetration testing across multiple

McDaniel, Patrick Drew

303

The Statewide Benefits Of Net-Metering In California  

E-Print Network [OSTI]

on the costs and benefits of NEM to the Governor and Legislature. 4 Id. 5 California Solar Future: Growing to the total, "bundled" energy rate, which includes not only the cost of generation, but transmission of 2013 3 See Net Energy Metering Cost-Effectiveness Evaluation, Energy and Environmental Economics, Inc

Kammen, Daniel M.

304

Secure and robust multipath routings for advanced metering infrastructure  

Science Journals Connector (OSTI)

A Smart Grid is the modernization of the electricity grid using communication technology with the prime goals of reducing energy consumption as well as cost increasing reliability and creating new services for all participants. It comprises key components ... Keywords: Advanced Metering Infrastructure, Last-mile access, Multipath routing protocols, Security, Smart grid, Wireless mesh network

Binod Vaidya; Dimitrios Makrakis; Hussein Mouftah

2013-11-01T23:59:59.000Z

305

ParkingMeter: Balancing Energy Savings and Service Availability  

E-Print Network [OSTI]

ParkingMeter: Balancing Energy Savings and Service Availability Riccardo Crepaldi University of Illinois at Urbana Champaign rcrepal2@illinois.edu Ryan Welsh University of Illinois at Urbana Champaign rjwelsh2@illinois.edu Robin H. Kravets University of Illinois at Urbana Champaign rhk@illinois

Kravets, Robin

306

Hydrostatic bearings for a turbine fluid flow metering device  

DOE Patents [OSTI]

A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion. 3 figs.

Fincke, J.R.

1982-05-04T23:59:59.000Z

307

Personal energy metering Simon Hay, Andrew Rice and Andy Hopper  

E-Print Network [OSTI]

based on energy and usage data collected over the course of a year. We also studied the addi- tionalPersonal energy metering Simon Hay, Andrew Rice and Andy Hopper {sjeh3,acr31,ah12}@cam.ac.uk Computer Laboratory, University of Cambridge 1 Introduction Every day each of us consumes a significant

Cambridge, University of

308

Commercial building end-use energy metering inventory  

SciTech Connect (OSTI)

Pacific Northwest Laboratory conducted a comprehensive inventory of end-use metered data. The inventory did not discover many sources of metered end-use data; however, research into existing data bases and extensive discussions with professionals associated with building energy conservation have enabled a clear characterization to be developed of the types of metered data that are required to further energy conservation in commercial buildings. Based on the results of the inventory and this clarification of data requirements, the adequacy of existing data bases has been assessed, and recommendations have been developed for future federal data collection efforts. A summary of sources of existing metered end-use data is provided in Section 2.1 and its adequacy has been summarized. Collection of further end-use metered data is both desirable and valuable for many areas of building energy conservation research. Empirical data are needed to address many issues which to date have been addressed using only simulation techniques. The adequacy of using simulation techniques for various purposes needs to be assessed through comparison with measured data. While these data are expensive to acquire, it is cost-effective to do so in the long run, and the need is not being served by the private market. The preceding conclusion based on results from the inventory of existing data highlights two important facts: First, although the data are widely desired in the private sector, they are not widely available. Second, where suitable data are publicly available and contain the desired supporting information, their collection has generally been funded by government-sponsored research.

Heidell, J.A.; Mazzucchi, R.P.; Reilly, R.W.

1985-03-01T23:59:59.000Z

309

"YEAR","MONTH","STATE","UTILITY CODE","UTILITY NAME","RESIDENTIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TOTAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","COMMERCIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","INDUSTRIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","TRANSPORTATION PHOTOVOLTAIC NET METERING CUSTOMER COUNT","TOTAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","RESIDENTIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION WIND ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL WIND INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL WIND INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL WIND INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION WIND INSTALLED NET METERING CAPACITY (MW)","TOTAL WIND INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL WIND NET METERING CUSTOMER COUNT","COMMERCIAL WIND NET METERING CUSTOMER COUNT","INDUSTRIAL WIND NET METERING CUSTOMER COUNT","TRANSPORTATION WIND NET METERING CUSTOMER COUNT","TOTAL WIND NET METERING CUSTOMER COUNT","RESIDENTIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL OTHER INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL OTHER INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL OTHER INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION OTHER INSTALLED NET METERING CAPACITY (MW)","TOTAL OTHER INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL OTHER NET METERING CUSTOMER COUNT","COMMERCIAL OTHER NET METERING CUSTOMER COUNT","INDUSTRIAL OTHER NET METERING CUSTOMER COUNT","TRANSPORTATION OTHER NET METERING CUSTOMER COUNT","TOTAL OTHER NET METERING CUSTOMER COUNT","RESIDENTIAL TOTAL ENERGY SOLD BACK TO THE UTILITY (MWh)","COMMERCIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION TOTAL INSTALLED NET METERING CAPACITY (MW)","TOTAL INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL TOTAL NET METERING CUSTOMER COUNT","COMMERCIAL TOTAL NET METERING CUSTOMER COUNT","INDUSTRIAL TOTAL NET METERING CUSTOMER COUNT","TRANSPORTATION TOTAL NET METERING CUSTOMER COUNT","TOTAL NET METERING CUSTOMER COUNT","RESIDENTIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","COMMERCIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","INDUSTRIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TRANSPORTATION ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TOTAL ELECTRIC ENERGY SOLD BACK TO THE UTILITYFOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"  

U.S. Energy Information Administration (EIA) Indexed Site

UTILITYFOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"

310

"YEAR","MONTH","STATE","UTILITY CODE","UTILITY NAME","RESIDENTIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TOTAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","COMMERCIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","INDUSTRIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","TRANSPORTATION PHOTOVOLTAIC NET METERING CUSTOMER COUNT","TOTAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","RESIDENTIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION WIND ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL WIND INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL WIND INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL WIND INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION WIND INSTALLED NET METERING CAPACITY (MW)","TOTAL WIND INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL WIND NET METERING CUSTOMER COUNT","COMMERCIAL WIND NET METERING CUSTOMER COUNT","INDUSTRIAL WIND NET METERING CUSTOMER COUNT","TRANSPORTATION WIND NET METERING CUSTOMER COUNT","TOTAL WIND NET METERING CUSTOMER COUNT","RESIDENTIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL OTHER INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL OTHER INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL OTHER INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION OTHER INSTALLED NET METERING CAPACITY (MW)","TOTAL OTHER INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL OTHER NET METERING CUSTOMER COUNT","COMMERCIAL OTHER NET METERING CUSTOMER COUNT","INDUSTRIAL OTHER NET METERING CUSTOMER COUNT","TRANSPORTATION OTHER NET METERING CUSTOMER COUNT","TOTAL OTHER NET METERING CUSTOMER COUNT","RESIDENTIAL TOTAL ENERGY SOLD BACK TO THE UTILITY (MWh)","COMMERCIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION TOTAL INSTALLED NET METERING CAPACITY (MW)","TOTAL INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL TOTAL NET METERING CUSTOMER COUNT","COMMERCIAL TOTAL NET METERING CUSTOMER COUNT","INDUSTRIAL TOTAL NET METERING CUSTOMER COUNT","TRANSPORTATION TOTAL NET METERING CUSTOMER COUNT","TOTAL NET METERING CUSTOMER COUNT","RESIDENTIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","COMMERCIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","INDUSTRIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TRANSPORTATION ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TOTAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"  

U.S. Energy Information Administration (EIA) Indexed Site

UTILITY FOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"

311

American Journal  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

American American Journal of Science JUNE 2007 GENERALIZATION OF GAS HYDRATE DISTRIBUTION AND SATURATION IN MARINE SEDIMENTS BY SCALING OF THERMODYNAMIC AND TRANSPORT PROCESSES GAURAV BHATNAGAR*, WALTER G. CHAPMAN*, GERALD R. DICKENS**, BRANDON DUGAN**, and GEORGE J. HIRASAKI* † ABSTRACT. Gas hydrates dominated by methane naturally occur in deep marine sediment along continental margins. These compounds form in pore space between the seafloor and a sub-bottom depth where appropriate stability conditions prevail. However, the amount and distribution of gas hydrate within this zone, and free gas below, can vary significantly at different locations. To understand this variability, we develop a one-dimensional numerical model that simulates the accumulation of gas hydrates in marine sediments due to upward and downward fluxes of methane over time. The model contains rigorous

312

Slide 1  

Broader source: Energy.gov (indexed) [DOE]

American American Samoa go to www.recovery.gov DOE Recovery Act projects in American Samoa: 4 U.S. DEPARTMENT OF ENERGY * AMERICAN SAMOA RECOVERY ACT SNAPSHOT The American Recovery & Reinvestment Act (ARRA) is making a meaningful down payment on the nation's energy and environmental future. The Recovery Act investments in American Samoa are supporting a broad range of clean energy projects, from energy efficiency and the smart grid to solar power and biofuels. Through these investments, American Samoa's businesses, universities, non- profits, and local governments are creating quality jobs today and positioning American Samoa to play an important role in the new energy economy of the future. EXAMPLES OF AMERICAN SAMOA FORMULA GRANTS Program Award (in millions) State Energy Program Weatherization Assistance

313

ESB Smart Meter Projects (Smart Grid Project) | Open Energy Information  

Open Energy Info (EERE)

ESB Smart Meter Projects ESB Smart Meter Projects Country Ireland Headquarters Location Cork, Ireland Coordinates 51.897873°, -8.471087° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":51.897873,"lon":-8.471087,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

314

Dead-time compensation for a logarithmic display rate meter  

DOE Patents [OSTI]

An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events.

Larson, John A. (Aurora, IL); Krueger, Frederick P. (Aurora, IL)

1988-09-20T23:59:59.000Z

315

Clustering of Meter-wave Luminous Objects toward Monoceros  

E-Print Network [OSTI]

A distribution of the meter-wave luminous objects, which are bright at frequency 74 MHz (a wavelength of 4 m) but not detectable at 1.4 GHz (21 cm) in the VLA surveys, shows a notable concentration in a scale of a few degrees toward Monoceros [(l, b)=(225, 4)]. We argue that it is a part of giant radio relics associated with a nearby cluster of galaxies with cz~2400$ km s^{-1} centered on the spiral galaxy NGC 2377. The angular separation of these objects from the clustering center is consistent with the separation of distant relics to the cluster center if scaled by distance. This fact implies that the concentrations of meter-wave luminous objects can be used as a tracer of the structure of the Local Supercluster and it's vicinity.

Shuji Deguchi; Kazutaka Koike

2008-11-19T23:59:59.000Z

316

Dead-time compensation for a logarithmic display rate meter  

DOE Patents [OSTI]

An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events. 5 figs.

Larson, J.A.; Krueger, F.P.

1987-10-05T23:59:59.000Z

317

Hydrostatic bearings for a turbine fluid flow metering device  

DOE Patents [OSTI]

A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion.

Fincke, J.R.

1980-05-02T23:59:59.000Z

318

Microsoft Word - eMeter 10-11-01 Response to DOE RFI.doc  

Broader source: Energy.gov (indexed) [DOE]

Addressing Policy and Logistical Challenges to smart grid Implementation: Addressing Policy and Logistical Challenges to smart grid Implementation: Response to Department of Energy RFI November 1, 2010 eMeter Strategic Consulting Background eMeter is a smart grid software company that provides smart network application platform (SNAP) software to integrate smart meters and smart grid communications networks and devices with utility IT systems. eMeter also provides smart grid application software such as meter data management (MDM) and consumer engagement software. Being vendor-neutral toward all meter, hardware, and legacy utility software systems (e.g. CIS and Billing), eMeter has a unique, unbiased and global perspective on smart grid IT issues. In addition, eMeter's principals have participated in the definition and development of the

319

The Economic Value of PV and Net Metering to Residential Customers in California  

E-Print Network [OSTI]

metering than with a feed-in tariff where all PV generationnet metering, MPR- based feed-in tariff, hourly netting, and1) An MPR-based feed-in tariff, under which the customer is

Darghouth, Naim

2010-01-01T23:59:59.000Z

320

100 Meter Time of Flight System for Transmission Experiments Michael Rapp, Yaron Danon, Robert Block  

E-Print Network [OSTI]

100 Meter Time of Flight System for Transmission Experiments Michael Rapp, Yaron Danon, Robert of the detectors was chosen to take advantage of the neutron beam geometry at the detector location, 100 meters

Danon, Yaron

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

WINDExchange: Utility-Scale Land-Based 80-Meter Wind Maps  

Wind Powering America (EERE)

Programs & Data Utility-Scale Land-Based 80-Meter Wind Maps The U.S. Department of Energy provides an 80-meter (m) height, high-resolution wind resource map for the United...

322

Why Is the Speed of Light in Meters Per Second What It Is? |...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Invention > Stump the Scientist > Why Is the Speed of Light in Meters Per Second What It Is? Why Is the Speed of Light in Meters Per Second What It Is? 2012.08.27 Chief Scientist...

323

Effects of geometric scaling on static pressure measurements in orifice flow-meters  

E-Print Network [OSTI]

. (Mech) University of Mysore, India Chair of Advisory Committee: Dr. G. L. Morrison It is estimated that there are over one million orifice meters in operation today in the United States of America. . The accuracy of these meters.... It is estimated that there are over one million orifice meters in operation today in the United States of America. The accuracy of these meters is such that uncertainties of millions of dollars a year result from their use [1]. The basic idea employed...

Sarker, Arunava

2012-06-07T23:59:59.000Z

324

Video game console usage and national energy consumption: Results from a field-metering study  

E-Print Network [OSTI]

with their free energy audit program. Meters were installedinstalled as part of an energy audit program. Users may be

Desroches, Louis-Benoit

2013-01-01T23:59:59.000Z

325

1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. HIGH-ACCURACY LASER POWER AND ENERGY METER CALIBRATION SYSTEM . . . . . . . . 2  

E-Print Network [OSTI]

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. HIGH-ACCURACY LASER POWER AND ENERGY METER CALIBRATION SYSTEM . . . . . . . . 2 2.1 Calibration

326

Status of Net Metering: Assessing the Potential to Reach Program Caps (Poster)  

SciTech Connect (OSTI)

Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

Heeter, J.; Bird, L.; Gelman, R.

2014-10-01T23:59:59.000Z

327

Status of Net Metering: Assessing the Potential to Reach Program Caps  

SciTech Connect (OSTI)

Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

Heeter, J.; Gelman, R.; Bird, L.

2014-09-01T23:59:59.000Z

328

United States- Land Based and Offshore Annual Average Wind Speed at 100 Meters  

Broader source: Energy.gov [DOE]

Full-size, high resolution version of the 100-meter land-based and offshore wind speed resource map.

329

Meter as Mechanism: A Neural Network that Learns Metrical Michael Gasser, Douglas Eck and Robert Port  

E-Print Network [OSTI]

Meter as Mechanism: A Neural Network that Learns Metrical Patterns Michael Gasser, Douglas Eck that apparently underlies both music and some examples of speech production is meter. Yet detailed measurements of pulses that conform to particular meters. In addition, beginning with an initial state with no biases

Gasser, Michael

330

Feeling Music: Integration of Auditory and Tactile Inputs in Musical Meter Perception  

E-Print Network [OSTI]

Feeling Music: Integration of Auditory and Tactile Inputs in Musical Meter Perception Juan Huang1 are integrated in humans performing a musical meter recognition task. Subjects discriminated between two types coherent meter percepts, and 3) Simultaneously presented bimodal inputs where the two channels contained

Wang, Xiaoqin

331

Detecting Meter in Recorded Music Joseph E. Flannick, Rachel W. Hall, and Robert Kelly  

E-Print Network [OSTI]

Detecting Meter in Recorded Music Joseph E. Flannick, Rachel W. Hall, and Robert Kelly Dept) to identify the primary rhythmic content of pieces of popular music. The meter of such pieces is deter- mined of energy bursts in each band. We found that the meters of the pieces we analyzed were characterized

Hall, Rachel W.

332

Broadband precision wavelength meter based on a stepping FabryProt interferometer  

E-Print Network [OSTI]

Broadband precision wavelength meter based on a stepping Fabry­Pérot interferometer T. J. Scholl. INTRODUCTION Wavelength meters based on Michelson or Fizeau inter- ferometers have long been the standard a more general laser wavelength meter in which the FP ring pattern was employed to compare

Rehse, Steven J.

333

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal Dutta  

E-Print Network [OSTI]

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal}@eecs.umich.edu culler@cs.berkeley.edu Abstract AC power meters require both voltage and current to be sampled physical proximity and fed into a single power metering de- vice. In this paper, we explore the viability

Dutta, Prabal

334

Behavioral/Systems/Cognitive Selective Neuronal Entrainment to the Beat and Meter  

E-Print Network [OSTI]

Behavioral/Systems/Cognitive Selective Neuronal Entrainment to the Beat and Meter Embedded Fundamental to the experience of music, beat and meter perception refers to the perception of periodicities the spontaneous building of beat and meter hypothesized to emerge from the selective entrainment of neuronal

335

RIS-M-2243 THE RADIOCHROMIC DYE FILM DOSE METER AS A POSSIBLE TEST OF PARTICLE  

E-Print Network [OSTI]

RIS?-M-2243 THE RADIOCHROMIC DYE FILM DOSE METER AS A POSSIBLE TEST OF PARTICLE TRACK THEORY Johnny-film radlochromlc dye cyanide plastic dose meter to Ionizing radiation of electrons and heavy charged particles - 1. INTRODUCTION The radiochromic dye cyanide film dose meter has been investigated as a pos- sible

336

TRACKING THE "ODD": METER INFERENCE IN A CULTURALLY DIVERSE MUSIC CORPUS  

E-Print Network [OSTI]

TRACKING THE "ODD": METER INFERENCE IN A CULTURALLY DIVERSE MUSIC CORPUS Andre Holzapfel New York, containing a variety of meter types. We demonstrate that by adapting the model to specific styles, we can track beats and down- beats in odd meter types like 9/8 or 7/8 with an accuracy significantly improved

337

C-Meter: A Framework for Performance Analysis of Computing Clouds  

E-Print Network [OSTI]

C-Meter: A Framework for Performance Analysis of Computing Clouds Nezih Yigitbasi, Alexandru Iosup virtualization and network communications overheads. To address these issues, we have designed and implemented C-Meter of computing clouds. Then, we present the architecture of the C-Meter framework and discuss several resource

Iosup, Alexandru

338

DESIGN OF INTELLIGENT CONDUCTIVITY METER BASED ON MSP430F149  

E-Print Network [OSTI]

DESIGN OF INTELLIGENT CONDUCTIVITY METER BASED ON MSP430F149 Yaoguang Wei, Jianqing Wang, Daoliang are agriculture information technology. dliangl@cau.edu.cn Abstract: An intelligent conductivity meter based on MSP430F149 microcontroller was proposed in this paper. The intelligent conductive meter was composed

339

Finding Meter in Music Using an Autocorrelation Phase Matrix and Shannon Douglas Eck  

E-Print Network [OSTI]

Finding Meter in Music Using an Autocorrelation Phase Matrix and Shannon Entropy Douglas Eck. This approach yields a good model for predicting the meter of a piece of music. Finally we can use the phase information in the matrix to align a can- didate meter with music, making it possible to perform beat

Eck, Doug

340

meters in CO2 euthanasia chambers. All CO2 euthanasia chambers in both  

E-Print Network [OSTI]

meters in CO2 euthanasia chambers. All CO2 euthanasia chambers in both the facilities and laboratories will need flow meters. ULAR is currently in the process of identifying a cost-effective, accurate, and durable flow meter to install in all of the CO2 chambers in all of the vivaria. When a specific model

Bushman, Frederic

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

A Scalable Soft Spot Analysis Methodology for Compound Noise Effects in Nano-meter Circuits  

E-Print Network [OSTI]

A Scalable Soft Spot Analysis Methodology for Compound Noise Effects in Nano-meter Circuits Chong@ece.ucsd.edu ABSTRACT Circuits using nano-meter technologies are becoming increasingly vulnerable to signal interference methodology to study the vulnerability of digital ICs exposed to nano-meter noise and transient soft errors

California at San Diego, University of

342

Principle and implementations of a refracto-nephelo-turbidi-meter for  

E-Print Network [OSTI]

1 Principle and implementations of a refracto-nephelo-turbidi-meter for seawater measurements B of physical oceanography requires a compact high-resolution in-situ salino-turbidi-meter to measure these two the requirements and challenges of refracto-turbidi-meter design from their measurement principles and correlations

Paris-Sud XI, Université de

343

Design study of 8 meter monolithic mirror UV/optical space telescope H. Philip Stahl  

E-Print Network [OSTI]

Design study of 8 meter monolithic mirror UV/optical space telescope H. Philip Stahl NASA Marshall Space Flight Center, Huntsville, AL 35812 ABSTRACT The planned Ares V launch vehicle with its 10 meter to 8 meter class monolithic primary mirror telescope to Sun-Earth L2 using an Ares V. Specific

Sirianni, Marco

344

Behavioral/Systems/Cognitive Tagging the Neuronal Entrainment to Beat and Meter  

E-Print Network [OSTI]

Behavioral/Systems/Cognitive Tagging the Neuronal Entrainment to Beat and Meter Sylvie Nozaradan,1 (BRAMS), Universite´ de Montre´al, Quebec C.P. 6128 H3C 3J7, Canada Feeling the beat and meter to the beat frequency. Most importantly, we found that meter imagery elicits an additional frequency tuned

345

A model of the VU (volume-unit) meter, with speech applications Bryce Lobdell  

E-Print Network [OSTI]

A model of the VU (volume-unit) meter, with speech applications Bryce Lobdell Jont Allen Beckman Institute, University of Illinois Urbana, IL 61801 (October 11, 2006) Running title: volume unit meter usage ABSTRACT The Volume Unit (VU) meter, used in speech research prior to the ad- vent of computers and modern

Allen, Jont

346

Gemini: A Non-Invasive, Energy-Harvesting True Power Meter Bradford Campbell and Prabal Dutta  

E-Print Network [OSTI]

Gemini: A Non-Invasive, Energy-Harvesting True Power Meter Bradford Campbell and Prabal Dutta,prabal}@umich.edu Abstract--Power meters are critical for submetering loads in residential and commercial settings, but high by proposing non-invasive meters that easily clip onto a wire, or stick onto a circuit breaker, to perform

Dutta, Prabal

347

Reference Directions for a Sound Level Meter , M.R. Vaabenb  

E-Print Network [OSTI]

0 and 90 Reference Directions for a Sound Level Meter E. Aflaloa , M.R. Vaabenb , P. Pourtaua , D the requirements of the IEC 61672 standard on sound level meters taking into account noise incidence from level meter must be pointed at the source according to standard IEC 60651. The purpose of the paper

Paris-Sud XI, Université de

348

MSET modeling of Crystal River-3 venturi flow meters.  

SciTech Connect (OSTI)

The analysis of archived Crystal River-3 feedwater flow data reveals a slow and steady degradation of the flow meter measurements during the 1992/1993 operating cycle. MSET can reliably estimate the true flow rate and quantify the degree of departure between the indicated signal and the true flow rate with high accuracy. The MSET computed flow rate could, in principle, be used to provide an improved estimate of the reactor power and hence avoid the revenue loss associated with derating the reactor based on a faulty feedwater flow rate indication.

Bockhorst, F. K.; Gross, K. C.; Herzog, J. P.; Wegerich, S. W.

1998-01-05T23:59:59.000Z

349

The Coldest Cubic Meter in the Known Universe  

E-Print Network [OSTI]

CUORE is a 741 kg array of TeO2 bolometers that will search for the neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso in Italy, where it will begin taking data in 2015. The CUORE cryostat will cool several metric tonnes of material to below 1 K and the CUORE detector itself will operate at a typical temperature of 10 mK. At this temperature, the CUORE detector will be the coldest contiguous cubic meter in the known Universe.

Jonathan Ouellet

2014-10-14T23:59:59.000Z

350

Meter-baseline tests of sterile neutrinos at Daya Bay  

E-Print Network [OSTI]

We explore the sensitivity of an experiment at the Daya Bay site, with a point radioactive source and a few meter baseline, to neutrino oscillations involving one or more eV mass sterile neutrinos. We find that within a year, the entire 3+2 and 1+3+1 parameter space preferred by global fits can be excluded at the 3\\sigma level, and if an oscillation signal is found, the 3+1 and 3+2 scenarios can be distinguished from each other at more than the 3\\sigma level provided one of the sterile neutrinos is lighter than 0.5 eV.

Y. Gao; D. Marfatia

2013-05-07T23:59:59.000Z

351

The Coldest Cubic Meter in the Known Universe  

E-Print Network [OSTI]

CUORE is a 741 kg array of TeO2 bolometers that will search for the neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso in Italy, where it will begin taking data in 2015. The CUORE cryostat will cool several metric tonnes of material to below 1 K and the CUORE detector itself will operate at a typical temperature of 10 mK. At this temperature, the CUORE detector will be the coldest contiguous cubic meter in the known Universe.

Ouellet, Jonathan

2014-01-01T23:59:59.000Z

352

2010 Assessment of Demand Response and Advanced Metering - Staff Report  

Broader source: Energy.gov (indexed) [DOE]

2010 Assessment of Demand Response and Advanced Metering Staff Report Federal Energy Regulatory Commission February 2011 The opinions and views expressed in this staff report do not necessarily represent those of the Federal Energy Regulatory Commission, its Chairman, or individual Commissioners, and are not binding on the Commission. ACKNOWLEDGEMENTS Federal Energy Regulatory Commission Staff Team Dean Wight, Team Lead Caroline Daly David Kathan Michael P. Lee Kamaria Martin Pamela Silberstein Michael Tita Rebecca Vertes Z, INC. Team Bryan Templeton (Z, INC.) Valerie Richardson (KEMA) Will Gifford (KEMA) Christopher Elsner (Z, INC.) Matthew S. Pettit (KEMA) Geoff Barker (KEMA) Ron Chebra (KEMA) TABLE OF CONTENTS Executive Summary

353

The magnetic flywheel flow meter: Theoretical and experimental contributions  

SciTech Connect (OSTI)

The development of contactless flow meters is an important issue for monitoring and controlling of processes in different application fields, like metallurgy, liquid metal casting, or cooling systems for nuclear reactors and transmutation machines. Shercliff described in his book The Theory of Electromagnetic Flow Measurement, Cambridge University Press, 1962 a simple and robust device for contact-less measurements of liquid metal flow rates which is known as magnetic flywheel. The sensor consists of several permanent magnets attached on a rotatable soft iron plate. This arrangement will be placed closely to the liquid metal flow to be measured, so that the field of the permanent magnets penetrates into the fluid volume. The flywheel will be accelerated by a Lorentz force arising from the interaction between the magnetic field and the moving liquid. Steady rotation rates of the flywheel can be taken as a measure for the mean flow rate inside the fluid channel. The present paper provides a detailed theoretical description of the sensor in order to gain a better insight into the functional principle of the magnetic flywheel. Theoretical predictions are confirmed by corresponding laboratory experiments. For that purpose, a laboratory model of such a flow meter was built and tested on a GaInSn-loop under various test conditions.

Buchenau, D., E-mail: d.buchenau@hzdr.de; Galindo, V.; Eckert, S. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstrae 400, 01328 Dresden (Germany)

2014-06-02T23:59:59.000Z

354

Meter scale plasma source for plasma wakefield experiments  

SciTech Connect (OSTI)

High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 10{sup 17} cm{sup -3} has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J. [Department of Electrical Engineering, University of California Los Angeles, Los Angeles, CA 90095 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

2012-12-21T23:59:59.000Z

355

Microsoft Word - CX-OTEC-West-JohnDaySub-MeterProjectFY13_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

Walker Miller Walker Miller Electrical Engineer - TPCF-PASCO Proposed Action: Revenue Meter Replacement at Oregon Trail Electric Co-op's (OTEC's) West John Day Substation PP&A Project No: 2595 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.7 Electronic Equipment Location: Grant County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace an old JEM1 revenue meter at OTEC's West John Day Substation. The meter would be replaced with a new JEMStar meter inside OTEC's existing control house. The new meter would allow BPA to meter load from a new transformer OTEC is installing. This meter will be installed by BPA personnel and it will remain the property and responsibility of BPA.

356

California Solar Initiative (CSI) Thermal Program Metering Installation Guide Purpose: The purpose of this metering installation guide is to provide participating eligible contractors  

E-Print Network [OSTI]

1 California Solar Initiative (CSI) Thermal Program Metering Installation Guide Purpose: The purpose of this metering installation guide is to provide participating eligible contractors in the CSI-Thermal to the mixing valve. Place the hot sensor on the pipe between the solar tank and the backup water heater. #12

357

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California  

E-Print Network [OSTI]

net metering, and policies for supporting solar deployment.net metering, and policies for supporting solar deployment.Energy Policy, 36: MRW & Associates. 2007. Solar PV and

Darghouth, Naim

2010-01-01T23:59:59.000Z

358

Smithsonian American Art Museum 1 Smithsonian American Art Museum  

E-Print Network [OSTI]

Smithsonian American Art Museum 1 Smithsonian American Art Museum INVENTORY OF AMERICAN PAINTINGS): ___________________________________ _____________________________________________________________________________ EXECUTION DATE (if approximate, precede with circa): _____________________________ MEDIA oil pastel for contributing information to the national Inventory of American Paintings. Address completed reports

Mathis, Wayne N.

359

Trillion Cubic Feet Billion Cubic Meters Residential Commercial  

Gasoline and Diesel Fuel Update (EIA)

2 2 4 6 8 10 0 50 100 150 200 250 Trillion Cubic Feet Billion Cubic Meters Residential Commercial Industrial Electric Utilities 1930 1935 1940 1945 1950 1955 1960 1965 1970 1980 1985 1990 1995 1975 2000 Note: In 1996, consumption of natural gas for agricultural use is classified as industrial use. In 1995 and earlier years, agricultural use was classified as commercial use. Sources: 1930-1975: Bureau of Mines, Minerals Yearbook, "Natural Gas" chapter. 1976-1978: Energy Information Administration (EIA), Energy Data Reports, Natural Gas Annual. 1979: EIA, Natural Gas Production and Consumption, 1979. 1980-1996: Form EIA- 176, "Annual Report of Natural and Supplemental Gas Supply and Disposition" and Form EIA-759, "Monthly Power Plant Report." 23. Natural Gas Delivered to Consumers in the United States, 1930-1996 Figure

360

ESB Smart Meter Projects (Smart Grid Project) (Limerick, Ireland) | Open  

Open Energy Info (EERE)

Projects (Smart Grid Project) (Limerick, Ireland) Projects (Smart Grid Project) (Limerick, Ireland) Jump to: navigation, search Project Name ESB Smart Meter Projects Country Ireland Headquarters Location Limerick, Ireland Coordinates 52.663857°, -8.626773° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":52.663857,"lon":-8.626773,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Microsoft Word - CX-Paisley_Meter_08Aug2013.doc  

Broader source: Energy.gov (indexed) [DOE]

3 3 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Robert Trismen Project Manager -TEP-CSB-1 Proposed Action: Paisley Geothermal Integration Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.7 Electronic Equipment Location: Lake County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to integrate Surprise Valley Electrification Corporation's (SVEC) 3.65-megawatt Paisley Geothermal Project into BPA's balancing authority (BA) in response to a SVEC small generator interconnection request. The proposed point of interconnection would be at SVEC's existing Paisley Substation. In order to integrate the proposed geothermal generation project, BPA would provide and review metering drawings,

362

Positron Beam Propagation in a Meter Long Plasma Channel  

SciTech Connect (OSTI)

Recent experiments and simulations have shown that positron beams propagating in plasmas can be focused and also create wakes with large accelerating gradients. For similar parameters, the wakes driven by positron beams are somewhat smaller compared to the case of an electron beam. Simulations have shown that the wake amplitude can be increased if the positron beam is propagated in a hollow plasma channel (Ref. 1). This paper, compares experimentally, the propagation and beam dynamics of a positron beam in a meter scale homogeneous plasma, to a positron beam hollow channel plasma. The results show that positron beams in hollow channels are less prone to distortions and deflections. Hollow channels were observed to guide the positron beam onto the channel axis. Beam energy loss was also observed implying the formation of a large wake amplitude. The experiments were carried out as part of the E-162 plasma wakefield experiments at SLAC.

Marsh, K.A.; Blue, B.E.; Clayton, C.E.; Joshi, C.; Mori, W.B.; /UCLA; Decker, F.-J.; Hogan, M.J.; Iverson, R.; O'Connell, C.; Raimondi, P.; Siemann, Robert H.; Walz, D.; /SLAC; Katsouleas, T.C.; Muggli, P.; /Southern California U.

2008-03-17T23:59:59.000Z

363

Quantum Metrology: Towards an alternative definition for the meter  

E-Print Network [OSTI]

The motivation for this article came from an attempt to give an alternative definition for the meter, the SI unit for measuring length. As a starting point towards this goal, in this piece of work we present the underlying theory behind our approach which uses ideas from quantum field theory and noncommutative geometry, in particular the notion of an odd K-cycle which is based on the Dirac operator (and its inverse, the Dirac propagator). Using (the perhaps more familiar) physics terminology, the key point in our strategy is this: instead of measuring length directly in space-time we measure the "algebraic (spectral) length" in the space of the corresponding quantum states of some particle (fermion) acted upon by the Dirac propagator. This approach shares the spirit of the unanimus vote of the 24th General Conference of Standards and Measures (21st October 2011) in Serves, France for the redefinition of the fundamental units using Planck's constant.

Ioannis P. Zois

2012-03-05T23:59:59.000Z

364

"YEAR","MONTH","STATE","UTILITY CODE","UTILITY NAME","RESIDENTIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TOTAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","COMMERCIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","INDUSTRIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","TRANSPORTATIONPHOTOVOLTAIC NET METERING CUSTOMER COUNT","TOTAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","RESIDENTIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION WIND ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL WIND INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL WIND INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL WIND INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION WIND INSTALLED NET METERING CAPACITY (MW)","TOTAL WIND INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL WIND NET METERING CUSTOMER COUNT","COMMERCIAL WIND NET METERING CUSTOMER COUNT","INDUSTRIAL WIND NET METERING CUSTOMER COUNT","TRANSPORTATION WIND NET METERING CUSTOMER COUNT","TOTAL WIND NET METERING CUSTOMER COUNT","RESIDENTIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL OTHER INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL OTHER INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL OTHER INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION OTHER INSTALLED NET METERING CAPACITY (MW)","TOTAL OTHER INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL OTHER NET METERING CUSTOMER COUNT","COMMERCIAL OTHER NET METERING CUSTOMER COUNT","INDUSTRIAL OTHER NET METERING CUSTOMER COUNT","TRANSPORTATION OTHER NET METERING CUSTOMER COUNT","TOTAL OTHER NET METERING CUSTOMER COUNT","RESIDENTIAL TOTAL ENERGY SOLD BACK TO THE UTILITY (MWh)","COMMERCIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION TOTAL INSTALLED NET METERING CAPACITY (MW)","TOTAL INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL TOTAL NET METERING CUSTOMER COUNT","COMMERCIAL TOTAL NET METERING CUSTOMER COUNT","INDUSTRIAL TOTAL NET METERING CUSTOMER COUNT","TRANSPORTATION TOTAL NET METERING CUSTOMER COUNT","TOTAL NET METERING CUSTOMER COUNT","RESIDENTIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","COMMERCIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","INDUSTRIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TRANSPORTATION ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TOTAL ELECTRIC ENERGY SOLD BACK TO THE UTILITYFOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"  

U.S. Energy Information Administration (EIA) Indexed Site

TRANSPORTATIONPHOTOVOLTAIC NET METERING CUSTOMER COUNT","TOTAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","RESIDENTIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION WIND ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL WIND INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL WIND INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL WIND INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION WIND INSTALLED NET METERING CAPACITY (MW)","TOTAL WIND INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL WIND NET METERING CUSTOMER COUNT","COMMERCIAL WIND NET METERING CUSTOMER COUNT","INDUSTRIAL WIND NET METERING CUSTOMER COUNT","TRANSPORTATION WIND NET METERING CUSTOMER COUNT","TOTAL WIND NET METERING CUSTOMER COUNT","RESIDENTIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL OTHER INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL OTHER INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL OTHER INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION OTHER INSTALLED NET METERING CAPACITY (MW)","TOTAL OTHER INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL OTHER NET METERING CUSTOMER COUNT","COMMERCIAL OTHER NET METERING CUSTOMER COUNT","INDUSTRIAL OTHER NET METERING CUSTOMER COUNT","TRANSPORTATION OTHER NET METERING CUSTOMER COUNT","TOTAL OTHER NET METERING CUSTOMER COUNT","RESIDENTIAL TOTAL ENERGY SOLD BACK TO THE UTILITY (MWh)","COMMERCIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION TOTAL INSTALLED NET METERING CAPACITY (MW)","TOTAL INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL TOTAL NET METERING CUSTOMER COUNT","COMMERCIAL TOTAL NET METERING CUSTOMER COUNT","INDUSTRIAL TOTAL NET METERING CUSTOMER COUNT","TRANSPORTATION TOTAL NET METERING CUSTOMER COUNT","TOTAL NET METERING CUSTOMER COUNT","RESIDENTIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","COMMERCIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","INDUSTRIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TRANSPORTATION ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TOTAL ELECTRIC ENERGY SOLD BACK TO THE UTILITYFOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"

365

Water resources data for Hawaii and other Pacific areas, water year 1989. Volume 2. Guam, Northern Mariana Islands, federated states of Micronesia, Palau, and American Samoa. Water-data report (Annual), 1 October 1988-30 September 1989  

SciTech Connect (OSTI)

Water-resources data for the 1989 water year for other Pacific areas consist of records of discharge, and water quality of streams and stage of a lake and reservoir; water levels and water quality in wells; stage in a tide gage; and rainfall. This report volume 2 contains discharge records for 26 gaging stations; stage only for 2 gaging stations; water quality at 11 gaging stations, one streamflow partial record station, and 54 wells; water levels for 28 observations wells; and tide stages for one tide gage station. Also included are 2 crest-stage partial record stations, 4 miscellaneous partial-record stations, 15 low-flow partial-record stations, and 19 rainfall stations.

Fontaine, R.A.; Kunishige, V.E.; Lum, M.G.

1996-05-01T23:59:59.000Z

366

American Recovery and Reinvestment Act Information Services  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Recovery and Reinvestment Act Recovery and Reinvestment Act Information Services American Recovery and Reinvestment Act American Recovery and Reinvestment Act Information Services American Recovery and Reinvestment Act American Recovery and Reinvestment Act Information Services American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act American Recovery and Reinvestment Act

367

NIST Releases Test Framework for Upgrading of Smart Meters | Department of  

Broader source: Energy.gov (indexed) [DOE]

NIST Releases Test Framework for Upgrading of Smart Meters NIST Releases Test Framework for Upgrading of Smart Meters NIST Releases Test Framework for Upgrading of Smart Meters July 12, 2012 - 10:46am Addthis The National Institute of Standards and Technology (NIST) has released a draft set of guidelines that will help utilities test their procedures for upgrading their smart meters securely from a remote location and determine whether their procedures conform with the National Electrical Manufacturers Association (NEMA) Standard for Smart Grid Upgradeability. Available now for public comment, the Advanced Metering Infrastructure Smart Meter Upgradeability Test Framework includes test procedures and detailed steps for conducting the test, reviewing results, and producing records to assess and report on these results.

368

Hydro-Québec Net Metering (Quebec, Canada) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Hydro-Québec Net Metering (Quebec, Canada) Hydro-Québec Net Metering (Quebec, Canada) Hydro-Québec Net Metering (Quebec, Canada) < Back Eligibility Commercial Agricultural Residential Savings Category Buying & Making Electricity Solar Program Info Funding Source Hydro-Quebec State Quebec Program Type Net Metering In line with Hydro-Québec's commitment to the environment and sustainable development, Hydro-Québec is supporting self-generation with a new rate offering: the net metering option. This option reflects a broad approach to energy efficiency. It is both environmentally friendly and advantageous for self-generators seeking to optimize their energy management. Net metering provides a way to act on convictions by using renewable energy and state-of-the-art technology to truly take control of consumption

369

Microsoft Word - CX-BentonCoPUD-FinleySubstationMeterProject_FY13_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

John Roeder John Roeder Contractor - TEP-CSB-1 Proposed Action: Revenue Meter Replacement at Benton County Public Utility District's (PUD) Finley Substation PP&A Project No: 2594 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.7 Electronic Equipment Location: Benton County, Washington Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace an existing JEM1 revenue meter with a new JEMStar revenue meter within an existing meter rack at Benton County PUD's Finley Substation. BPA would own the rack and meter. No ground disturbance or alteration to the meter house would occur. Findings: BPA has determined that the proposed action complies with Section 1021.410 and

370

Vids4Grids: Smart Meters and Super Cables | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Grids: Smart Meters and Super Cables Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables March 14, 2011 - 4:46pm Addthis This episode of Vids 4 Grids will take us to Itron's smart meter factory in West Union, SC where we will learn the role smart meters play in the Smart Grid. Deborah J. Buterbaugh Energy Project Specialist at National Energy Technology Laboratory What does this mean for me? Smart meters allow consumers to get real time information about their energy usage. Super cables help provide more reliable electricity to your home. In January we introduced you to the Vids4Grids project, a series of videos targeting students in high school and starting college. Through integration into curricula and online posting for open viewing, the project aims to increase awareness and create interest in power systems careers to help

371

Vids4Grids: Smart Meters and Super Cables | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Vids4Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables March 14, 2011 - 4:46pm Addthis This episode of Vids 4 Grids will take us to Itron's smart meter factory in West Union, SC where we will learn the role smart meters play in the Smart Grid. Deborah J. Buterbaugh Energy Project Specialist at National Energy Technology Laboratory What does this mean for me? Smart meters allow consumers to get real time information about their energy usage. Super cables help provide more reliable electricity to your home. In January we introduced you to the Vids4Grids project, a series of videos targeting students in high school and starting college. Through integration into curricula and online posting for open viewing, the project aims to increase awareness and create interest in power systems careers to help

372

Have You Used an Electric Meter to Measure Your Energy Use? | Department of  

Broader source: Energy.gov (indexed) [DOE]

Have You Used an Electric Meter to Measure Your Energy Use? Have You Used an Electric Meter to Measure Your Energy Use? Have You Used an Electric Meter to Measure Your Energy Use? December 10, 2009 - 7:30am Addthis This week, you read about using an electric meter to measure and manage your energy use. Using a meter could make you more conscious of exactly what items are costing you the most money. Plus, it can be kind of fun to put actual numbers to the various items in your home. Have you used an electric meter to measure your energy use? Tell us about your experience. Each Thursday, you have the chance to share your thoughts on a question about energy efficiency or renewable energy for consumers. E-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov. Addthis Related Articles You Can't Manage Energy Use That You Don't Measure

373

VP 100: Smart Meters Will Help Customers Avoid High Electric Bills |  

Broader source: Energy.gov (indexed) [DOE]

Smart Meters Will Help Customers Avoid High Electric Bills Smart Meters Will Help Customers Avoid High Electric Bills VP 100: Smart Meters Will Help Customers Avoid High Electric Bills October 4, 2010 - 3:00pm Addthis An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB Kevin Craft What are the key facts? EPB will install approximately 170,000 smart meters and 1,500 automated switches. They have the potential to provide a $300 million value to EPB and customers over a ten-year period. "Last winter I received a call from my son saying he had a $400 electric

374

VP 100: Smart Meters Will Help Customers Avoid High Electric Bills |  

Broader source: Energy.gov (indexed) [DOE]

VP 100: Smart Meters Will Help Customers Avoid High Electric Bills VP 100: Smart Meters Will Help Customers Avoid High Electric Bills VP 100: Smart Meters Will Help Customers Avoid High Electric Bills October 4, 2010 - 3:00pm Addthis An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB Kevin Craft What are the key facts? EPB will install approximately 170,000 smart meters and 1,500 automated switches. They have the potential to provide a $300 million value to EPB and customers over a ten-year period. "Last winter I received a call from my son saying he had a $400 electric

375

Ambit Energy American Airlines  

E-Print Network [OSTI]

ACT Dallas Amazon Ambit Energy American Airlines American Eagle ARGO Armor Wealth Management Army Energy Future Holdings Enterprise Rent-A-Car FactSet Research Systems Fidelity Investments First

O'Toole, Alice J.

376

Buy American Program Guidance  

Broader source: Energy.gov [DOE]

Guidance on the Buy American provision as applied to Energy Efficiency and Renewable Energy Projects funded by the American Recovery and Reinvestment Act of 2009. Office of EERE Guidance effective December 17, 2009.

377

Mooring Motion Bias of Point-Doppler Current Meter Measurements Paul Freitag, Michael McPhaden, Chris Meinig, Patricia Plimpton  

E-Print Network [OSTI]

Mooring Motion Bias of Point-Doppler Current Meter Measurements Paul Freitag, Michael Mc). Until 1998 the moorings were instrumented with mechanical current meters (MCMs, either Vector Averaging Current Meters (VACM) or Vector Measuring Current Meters (VMCM)). Comparison with nearby subsurface 150 k

378

Four Current Meter Models Compared in Strong Currents in Drake Passage D. RANDOLPH WATTS, MAUREEN A. KENNELLY, KATHLEEN A. DONOHUE,  

E-Print Network [OSTI]

Four Current Meter Models Compared in Strong Currents in Drake Passage D. RANDOLPH WATTS, MAUREEN A February 2013, in final form 11 June 2013) ABSTRACT Seven current meters representing four models: two vector-measuring current meters (VMCMs), two Aanderaa recording current meter (RCM) 11s, two

Rhode Island, University of

379

A study of the coherent structures and installation effects in an orifice flow meter  

E-Print Network [OSTI]

. Errors on the order of approximately 250 millions of dollar per year have been estimated for the natural gas industry. The urgent need to improve the accuracy has fueled basic research in the area of orifice flow meters. The objectives of this present... study were to analyze the coherent structures present in an orifice flow meter, and to examine the effect of a flow conditioner placed upstream of the orifice plate on the flow meter's accuracy, The coherent structures were measured by performing...

Pattabhi, Srikanth

2012-06-07T23:59:59.000Z

380

Metering and the New Federal Requirements of Energy Policy Act 2005  

E-Print Network [OSTI]

METERING AND THE NEW FEDERAL REQUIREMENTS OF ENERGY POLICY ACT 2005 Ab Ream Federal Energy Management Program U.S. Department of Energy Washington, DC Malcolm E. Verdict Energy Systems Laboratory Texas A&M University System College... Station, Texas ABSTRACT Section 103 of the Energy Policy Act of 2005 (EPAct 2005) (1) mandates the installation of meters and advanced electric meters on all Federal Buildings by 2012 using guidelines developed by the US Department of Energy...

Ream, A.; Verdict, M.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

NIST Special Publication 1039r1 Liquid Flow Meter Calibrations with the  

E-Print Network [OSTI]

NIST Special Publication 1039r1 Liquid Flow Meter Calibrations with the 0.1 L/s and the 2.5 L Publication 1039r1 Liquid Flow Meter Calibrations with the 0.1 L/s and the 2.5 L/s Piston Provers Jodie G. Technol. Spec. Publ. 1039r1, 55 pages (December 2013) CODEN: NSPUE2 #12;Liquid Flow Meter Calibrations

382

Feasibility of the design of dual-lane ramp meters in Texas  

E-Print Network [OSTI]

Of Single- And Dual-Lane Ramp Meters . . . . . . . . . . . . . Microscopic Simulation Analysis Of Traffic Control And Operational Characteristics . 58 60 61 63 65 65 66 V STUDY RESULTS . . . 72 Gessner Street/Katy Freeway Single-Lane Ramp Meter... . . . . . . 108 APPENDIX A DUAL-LANE RAMP METER SURVEY AND MAILING LIST . . . . . . 112 APPENDIX B MAY 1997 QUEUE AND DEMAND VOLUME DATA FOR THE GESSNER STREET/KATY FREEWAY SINGLE-LANE RAMP . . . . 120 APPENDIX C PROPOSED GESSNER STREET/KATY FREEWAY DUAL...

Butorac, Marc Allen

2012-06-07T23:59:59.000Z

383

Genetic fuzzy logic approach to local ramp metering control using microscopic traffic simulation.  

E-Print Network [OSTI]

??Ramp metering, one of the most effective solutions for improving motorway traffic flows, is playing increasingly important role in traffic management systems. Because of its (more)

Yu, Xue Feng

2009-01-01T23:59:59.000Z

384

Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve  

SciTech Connect (OSTI)

A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

Song, Li; Wang, Gang; Brambley, Michael R.

2013-04-28T23:59:59.000Z

385

Systematic Errors in Measuring the Energy of Wet Steam with Dry-Steam Meters  

Science Journals Connector (OSTI)

Systematic errors are considered in measuring mass flow rate, specific enthalpy, thermal power, and energy for wet steam by means of meters intended for dry saturated steam.

E. G. Abarinov; K. S. Sarelo

2002-03-01T23:59:59.000Z

386

Experience in the Application of Single-Beam Ultrasonic Flow Meters for Turbines  

SciTech Connect (OSTI)

Experience in the use of ultrasonic flow meters at the Bratskaya and Vilyuiskaya HPP is described. The article is of interest to field engineers.

Krasilnikov, A. M.; Dmitriev, S. G. [Joint-Stock Company 'Research Institute for Power Constructions' (Russian Federation); Karyakin, V. A. [Zagorsk Hydroelectric Pumped Storage Power Plant (Russian Federation)

2002-03-15T23:59:59.000Z

387

Meter Damage: Many customers have questions about who is responsible for repair to the electrical service at their homes. These pages may help to answer  

E-Print Network [OSTI]

Meter Damage: Many customers have questions about who is responsible for repair. weather head stack meter base connectors house knob weather head connectors mast clamp stack meter base meter meter #12; Let's start with definitions: Meter base: This is the metal box mounted

Rose, Annkatrin

388

Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering  

E-Print Network [OSTI]

The Private and Public Economies of Renewable Electricityprivate sector, began to push for deregulation in the electricityprivate customer value of behind-the-meter PV generation, as potential customers most often will consider the value of avoided electricity

Darghouth, Naim Richard

2013-01-01T23:59:59.000Z

389

The American Recovery  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Advanced Metering Infrastructure Electric Distribution Electric Transmission Customer Systems Equipment Manufacturing 13 10 5 2 4,925,826,664 1,997,812,053 511,700,775...

390

Ash level meter for a fixed-bed coal gasifier  

DOE Patents [OSTI]

An ash level meter for a fixed-bed coal gasifier is provided which utilizes the known ash level temperature profile to monitor the ash bed level. A bed stirrer which travels up and down through the extent of the bed ash level is modified by installing thermocouples to measure the bed temperature as the stirrer travels through the stirring cycle. The temperature measurement signals are transmitted to an electronic signal process system by an FM/FM telemetry system. The processing system uses the temperature signals together with an analog stirrer position signal, taken from a position transducer disposed to measure the stirrer position to compute the vertical location of the ash zone upper boundary. The circuit determines the fraction of each total stirrer cycle time the stirrer-derived bed temperature is below a selected set point, multiplies this fraction by the average stirrer signal level, multiplies this result by an appropriate constant and adds another constant such that a 1 to 5 volt signal from the processor corresponds to a 0 to 30 inch span of the ash upper boundary level. Three individual counters in the processor store clock counts that are representative of: (1) the time the stirrer temperature is below the set point (500.degree. F.), (2) the time duration of the corresponding stirrer travel cycle, and (3) the corresponding average stirrer vertical position. The inputs to all three counters are disconnected during any period that the stirrer is stopped, eliminating corruption of the measurement by stirrer stoppage.

Fasching, George E. (Morgantown, WV)

1984-01-01T23:59:59.000Z

391

Flow meter evaluation for U.S. Navy Public Works Center, San Diego, California  

SciTech Connect (OSTI)

The U.S. Navy Public Works Center San Diego (PWCSD) was concerned about the accuracy of various flow meters on steam and compressed air lines serving Naval facilities in San Diego, California. The flow meters had experienced various inconsistencies that had not been resolved prior to July 1993. Pacific Northwest Laboratory, Richland, Washington, evaluated the operation of 10 out of 79 steam and compressed air flow meters at PWCSD. The evaluation was limited to analysis of historical information and review of existing operating procedures. On-site investigation of the flow meters was limited to external observations of the flow-sensing equipment and a check of the flow computer program. PNL did not remove installed sensing equipment (i.e., flow meters or temperature or pressure sensors) to evaluate existing condition or check calibration. Although many of the flow meter errors can be traced to improperly normalized readings and to meters improperly compensated for temperature and pressure, lack of regular maintenance, including proper calibration, was evidenced throughout this study. A strict calibration schedule should be established for all steam and air flow meters, including calibration of the temperature sensor, pressure sensor, and flow turbine. It is recommended that the most crucial flow meters (such as the 10 evaluated in this study) be calibrated yearly. The remaining 69 flow meters could be placed on a staggered, biyearly calibration schedule. Calibration should be done by qualified personnel only. Improper calibration is often worse than no calibration at all. An outside firm is recommended to be contracted with to perform all maintenance and calibration on flow meters at the Naval facilities. Use of an outside firm would better facilitate regular, reliable calibration while removing liability for damaged parts.

Chvala, W.D. Jr.; McMordie, K.L.; Szydlowski, R.F.

1995-06-01T23:59:59.000Z

392

North American Electric Reliability Corporation Interconnections...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

North American Electric Reliability Corporation Interconnections North American Electric Reliability Corporation Interconnections Map of the North American Electric Reliability...

393

American Reinvestment Recovery Act | Department of Energy  

Energy Savers [EERE]

American Reinvestment Recovery Act American Reinvestment Recovery Act Federal Energy Regulatory Commission Loan Program American Reinvestment Recovery Act More Documents &...

394

Response of a slotted plate flow meter to horizontal two phase flow  

E-Print Network [OSTI]

meter is always better in performance and accuracy than the standard orifice plate flow meter. This study is primarily based on how a slotted plate responds to horizontal two-phase flow with air and water being used as the working fluids. The plates...

Muralidharan, Vasanth

2005-02-17T23:59:59.000Z

395

Unaccounted-for gas project. Measurement Task Force (orifice meter studies). Volume 2B. Final report  

SciTech Connect (OSTI)

The study was aimed at determining unaccounted-for (UAF) gas volumes resulting from operating Pacific Gas and Electric Co.'s transmission and distribution systems during 1987. Activities and methods are described and results are presented for research conducted on orifice meter accuracy. The Measurement Task Force determined that orifice metering inaccuracies were the largest single contributor to 1987 UAF.

Godkin, B.J.; Robertson, J.D.; Wlasenko, R.G.; Cowgill, R.M.; Grinstead, J.R.

1990-06-01T23:59:59.000Z

396

Quantum noise of non-ideal Sagnac speed meter interferometer with asymmetries  

E-Print Network [OSTI]

The speed meter concept has been identified as a technique that can potentially provide laser-interferometric measurements at a sensitivity level which surpasses the Standard Quantum Limit (SQL) over a broad frequency range. As with other sub-SQL measurement techniques, losses play a central role in speed meter interferometers and they ultimately determine the quantum noise limited sensitivity that can be achieved. So far in the literature, the quantum noise limited sensitivity has only been derived for lossless or lossy cases using certain approximations (for instance that the arm cavity round trip loss is small compared to the arm cavity mirror transmission). In this article we present a generalised, analytical treatment of losses in speed meters that allows accurate calculation of the quantum noise limited sensitivity of Sagnac speed meters with arm cavities. In addition, our analysis allows us to take into account potential imperfections in the interferometer such as an asymmetric beam splitter or differences of the reflectivities of the two arm cavity input mirrors. Finally,we use the examples of the proof-of-concept Sagnac speed meter currently under construction in Glasgow and a potential implementation of a Sagnac speed meter in the Einstein Telescope (ET) to illustrate how our findings affect Sagnac speed meters with meter- and kilometre-long baselines.

S. L. Danilishin; C. Graef; S. S. Leavey; J. Hennig; E. A. Houston; D. Pascucci; S. Steinlechner; J. Wright; S. Hild

2014-12-02T23:59:59.000Z

397

Trinity College Green Week 2012 Energy Competition Win a Domestic Energy Meter  

E-Print Network [OSTI]

Trinity College Green Week 2012 Energy Competition ­ Win a Domestic Energy Meter As part of College Green Week the "e3" programme and Director of Buildings Office is promoting an energy related would you like to win a domestic whole house energy meter as part of Trinity College Green Week 2012

O'Mahony, Donal E.

398

THE CONGESTION PIE: DELAY FROM COLLISIONS, POTENTIAL RAMP METERING GAIN, AND EXCESS DEMAND  

E-Print Network [OSTI]

THE CONGESTION PIE: DELAY FROM COLLISIONS, POTENTIAL RAMP METERING GAIN, AND EXCESS DEMAND the great potential to mitigate congestion by ramp metering. In addition to the three congestion pie slices in the division of the congestion `pie' into its constituent slices as in Figure 1. Knowledge of the congestion

Varaiya, Pravin

399

Performance Evaluation of Adaptive Ramp-Metering Algorithms Using Microscopic Traffic Simulation Model  

E-Print Network [OSTI]

to implementation on the target freeway network. In this paper, a capability-enhanced PARAMICS simulation model has evaluation; Simulation models; Algorithms. Introduction Ramp metering has been recognized as an effectivePerformance Evaluation of Adaptive Ramp-Metering Algorithms Using Microscopic Traffic Simulation

Levinson, David M.

400

Testing of 3-meter Prototype Fault Current Limiting Cables  

SciTech Connect (OSTI)

Two 3-m long, single-phase cables have been fabricated by Ultera from second generation (2G) superconductor supplied by American Superconductor. The first cable was made with two layers of 2G tape conductor and had a critical current of 5,750 A while the second cable had four layers and a critical current of 8,500 A. AC loss was measured for both cables at ac currents of up to 4 kArms. Ultera performed initial fault current studies of both cables in Denmark with limited currents in the range from 9.1 to 44 kA. Results from these tests will provide a basis for a 25-m long, three-phase, prototype cable to be tested at ORNL early next year and a 300-m long, fault current limiting, superconducting cable to be installed in a ConEd substation in New York City.

Gouge, Michael J [ORNL] [ORNL; Duckworth, Robert C [ORNL] [ORNL; Demko, Jonathan A [ORNL] [ORNL; Rey, Christopher M [ORNL] [ORNL; Thompson, James R [ORNL] [ORNL; Lindsay, David T [ORNL] [ORNL; Tolbert, Jerry Carlton [ORNL] [ORNL; Willen, Dag [Ultera] [Ultera; Lentge, Heidi [Ultera] [Ultera; Thidemann, Carsten [Ultera] [Ultera; Carter, Bill [AMSC] [AMSC

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Hanford Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped  

Broader source: Energy.gov (indexed) [DOE]

Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped Four Months Ahead of Schedule Hanford Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped Four Months Ahead of Schedule June 2, 2011 - 12:00pm Addthis Media Contact Cameron Hardy, DOE (509) 376-5365 Cameron.Hardy@rl.doe.gov RICHLAND, WASH. - The U.S. Department of Energy (DOE) at Hanford surpassed a Tri-Party Agreement Milestone by four months in shipping 1,000 cubic meters of transuranic waste off the Hanford Site in route to the Waste Isolation Pilot Plant (WIPP) in New Mexico before September 30, 2011. The milestone for shipping waste was met in May 2011. Since the shipments began in 2000, 620 shipments have left the Hanford Site, a total of 4,137 cubic meters of transuranic waste. Milestones for

402

Tips: Smart Meters and a Smarter Power Grid | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tips: Smart Meters and a Smarter Power Grid Tips: Smart Meters and a Smarter Power Grid Tips: Smart Meters and a Smarter Power Grid July 2, 2012 - 8:13pm Addthis The Smart Grid will consist of controls, computers, automation, and new technologies and equipment -- including a smart meter at your home -- working together to respond digitally to our quickly changing electric demand. The Smart Grid will consist of controls, computers, automation, and new technologies and equipment -- including a smart meter at your home -- working together to respond digitally to our quickly changing electric demand. What are the key facts? Like the Internet, the Smart Grid will consist of controls, computers, automation, and new technologies and equipment working together to respond digitally to our quickly changing electric demand.

403

Hydro-Québec Net Metering (Quebec, Canada) | Open Energy Information  

Open Energy Info (EERE)

Hydro-Québec Net Metering (Quebec, Canada) Hydro-Québec Net Metering (Quebec, Canada) No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Last modified on February 13, 2013. EZFeed Policy Place Quebec, Canada Applies to Utility Hydro-Quebec Name Hydro-Québec Net Metering (Quebec, Canada) Policy Type Net Metering Affected Technologies Geothermal Electric, Solar Photovoltaics Active Policy Yes Implementing Sector Utility Funding Source Hydro-Quebec Primary Website http://www.hydroquebec.com/self-generation/index.html Summary In line with Hydro-Québec's commitment to the environment and sustainable development, Hydro-Québec is supporting self-generation with a new rate offering: the net metering option. This option reflects a broad approach to

404

Demand Response and Smart Metering Policy Actions Since the Energy Policy  

Broader source: Energy.gov (indexed) [DOE]

and Smart Metering Policy Actions Since the Energy and Smart Metering Policy Actions Since the Energy Policy Act of 2005: A Summary for State Officials Demand Response and Smart Metering Policy Actions Since the Energy Policy Act of 2005: A Summary for State Officials This report represents a review of policy developments on demand response and other related areas such as smart meters and smart grid. It has been prepared by the Demand Response Coordinating Committ ee (DRCC) for the National Council on Electricity Policy (NCEP). The report focuses on State and Federal policy developments during the period from 2005 to mid-year 2008. It is an att empt to catalogue information on policy developments at both the federal and state level, both in the legislative and regulatory arenas. Demand Response and Smart Metering Policy Actions Since the Energy Policy

405

Hanford Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped  

Broader source: Energy.gov (indexed) [DOE]

Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped Four Months Ahead of Schedule Hanford Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped Four Months Ahead of Schedule June 2, 2011 - 12:00pm Addthis Media Contact Cameron Hardy, DOE (509) 376-5365 Cameron.Hardy@rl.doe.gov RICHLAND, WASH. - The U.S. Department of Energy (DOE) at Hanford surpassed a Tri-Party Agreement Milestone by four months in shipping 1,000 cubic meters of transuranic waste off the Hanford Site in route to the Waste Isolation Pilot Plant (WIPP) in New Mexico before September 30, 2011. The milestone for shipping waste was met in May 2011. Since the shipments began in 2000, 620 shipments have left the Hanford Site, a total of 4,137 cubic meters of transuranic waste. Milestones for

406

Experimental test results presented for field-damaged orifice meter plates  

SciTech Connect (OSTI)

Tests demonstrate that, unlike other types of meters, there is minimal loss of accuracy with orifice meters even when operational excursions are such that severe damage occurs. Both flange taps and pipe taps effectively have the same general pattern in that the actual coefficient increases with increasing permanent deformation. Of the two types of orifice tap, these data indicate that flange-tapped orifices may be less susceptible to severe deformation. This is probably caused by changes in the local pressure gradients in the vicinity of the plate. Since pipe taps are at such a large distance from the plate, these changes are probably not noticeable due to the turbulent mixing that takes place. With orifice meters, visual inspection of the plates after severe operation is recommended, to tell the user if the plate is beyond specifications. With other types of meters (i.e., other than differential meters) recalibration is the only method of determining if the meter has been affected. Where damage is apparent, the plate (or the meter if it is not of the differential type) should be immediately replaced.

Teyssandier, R.G.; Chisman, W.E.

1984-04-30T23:59:59.000Z

407

The Impact of Rate Design and Net Metering on the Bill Savings from  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Impact of Rate Design and Net Metering on the Bill Savings from The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California Title The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California Publication Type Report Refereed Designation Unknown Year of Publication 2010 Authors Darghouth, Naïm, Galen L. Barbose, and Ryan H. Wiser Pagination 62 Date Published 04/2010 Publisher LBNL City Berkeley Keywords electricity markets and policy group, electricity rate design, energy analysis and environmental impacts department, net metering, photovoltaics Abstract Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption.1 Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). Though net metering has played an important role in jump-starting the PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the bill-savings value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings benefits of PV varies under net metering, and how the bill savings under net metering compares to savings associated with other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE).3 The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state. We focus on these two utilities, both because we had ready access to a sample of load data for their residential customers, and because their service territories are the largest markets for residential PV in the country.

408

Instrument Qualification of Custom Fabricated Water Activity Meter for Hot Cell Use  

SciTech Connect (OSTI)

This report describes a custom fabricated water activity meter and the results of the qualification of this meter as described in the laboratory test plan LAB-PLN-11-00012, Testing and Validation of an Enhanced Acquisition and Control System. It was calibrated against several NaOH solutions of varying concentrations to quantify the accuracy and precision of the instrument at 20 C and 60 C. Also, a schematic and parts list of the equipment used to make the water activity meter will be presented in this report.

McCoskey, Jacob K.

2014-01-22T23:59:59.000Z

409

American Chemical Society Award Winners, Chicago, III.  

Science Journals Connector (OSTI)

American Chemical Society Award Winners, Chicago, III. ... Copyright 1970 American Chemical Society ...

1970-10-01T23:59:59.000Z

410

A model of the VU (volume-unit) meter, with speech applications Bryce E. Lobdell and Jont B. Allen  

E-Print Network [OSTI]

A model of the VU (volume-unit) meter, with speech applications Bryce E. Lobdell and Jont B. Allen October 2006; accepted 12 October 2006 The Volume-Unit VU meter, used in speech research prior. There are no known software implementations of this meter, which meet the 1954 ASA standard and provide

Allen, Jont

411

Monjolo: An Energy-Harvesting Energy Meter Architecture Samuel DeBruin, Bradford Campbell, and Prabal Dutta  

E-Print Network [OSTI]

Monjolo: An Energy-Harvesting Energy Meter Architecture Samuel DeBruin, Bradford Campbell 48109 {sdebruin,bradjc,prabal}@eecs.umich.edu ABSTRACT Conventional AC power meters perform at least two distinct func- tions: power conversion, to supply the meter itself, and energy me- tering, to measure

Dutta, Prabal

412

Electricit de France's study of the acoustic scintillation flow meter results in expanding its range and sensitivity  

E-Print Network [OSTI]

Electricité de France's study of the acoustic scintillation flow meter results in expanding its to study the Acoustic Scintillation Flow Meter (ASFM) developed by ASL AQFlow. The study was done for the next generation of acoustic scintillation flow meters. 1. Background For EDF's hydraulic power division

Paris-Sud XI, Université de

413

Traffic Equilibration: The Case of the Twin Cities Ramp Meter Shut Off David Levinson1and Atif Sheikh2  

E-Print Network [OSTI]

Traffic Equilibration: The Case of the Twin Cities Ramp Meter Shut Off David Levinson1and Atif Sheikh2 Abstract In Fall 2000, more than 430 ramp meters in the Twin Cities metropolitan area were shut down in order to evaluate the effectiveness of the metering system. This shutdown disturbed normal

Levinson, David M.

414

SDG&E Customers Can Connect Home Area Network Devices With Smart Meters |  

Open Energy Info (EERE)

SDG&E Customers Can Connect Home Area Network Devices With Smart Meters SDG&E Customers Can Connect Home Area Network Devices With Smart Meters Home > Groups > Utility Rate Graham7781's picture Submitted by Graham7781(2002) Super contributor 16 January, 2013 - 11:09 OpenEI San Diego Gas and Electric Smart Meters Smartgrid article reposted from Smartgrid.gov SAN DIEGO, Jan. 10, 2013 - San Diego Gas & Electric (SDG&E) customers can now purchase and install home area network devices to see how much energy they are using in near real-time and help identify high energy use appliances. With in-home energy display devices connected to their electric smart meters, SDG&E customers have access to a new tool to help them make smart energy consumption decisions to reduce their overall energy usage and costs. SDG&E has tested several new in-home energy display devices and customers

415

Development of 2-Meter Soil Temperature Probes and Results of Temperature  

Open Energy Info (EERE)

Development of 2-Meter Soil Temperature Probes and Results of Temperature Development of 2-Meter Soil Temperature Probes and Results of Temperature Survey Conducted at Desert Peak, Nevada, USA Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Development of 2-Meter Soil Temperature Probes and Results of Temperature Survey Conducted at Desert Peak, Nevada, USA Abstract Temperature gradient drilling has historically been a key tool in the exploration for geothermal resources in the Great Basin, USA but regulatory, environmental, and accessibility issues, as well as the expense of drilling, are increasingly limiting its use. In cases where thermal groundwater is not overlain by near-surface cold aquifers, temperatures measured at a depth of 2-meters is an efficient method for mapping thermal anomalies at a high level of detail. This is useful for augmenting deeper

416

Pantex installs new meters to help to reduce energy consumption | National  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

meters to help to reduce energy consumption | National meters to help to reduce energy consumption | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex installs new meters to help to ... Pantex installs new meters to help to reduce energy consumption Posted By Office of Public Affairs Project Manager Janice Clark gives a safety briefing.

417

Tips: Smart Meters and a Smarter Power Grid | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Tips: Smart Meters and a Smarter Power Grid Tips: Smart Meters and a Smarter Power Grid July 2, 2012 - 8:13pm Addthis The Smart Grid will consist of controls, computers, automation, and new technologies and equipment -- including a smart meter at your home -- working together to respond digitally to our quickly changing electric demand. The Smart Grid will consist of controls, computers, automation, and new technologies and equipment -- including a smart meter at your home -- working together to respond digitally to our quickly changing electric demand. What are the key facts? Like the Internet, the Smart Grid will consist of controls, computers, automation, and new technologies and equipment working together to respond digitally to our quickly changing electric demand.

418

Pantex installs new meters to help to reduce energy consumption | National  

National Nuclear Security Administration (NNSA)

meters to help to reduce energy consumption | National meters to help to reduce energy consumption | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex installs new meters to help to ... Pantex installs new meters to help to reduce energy consumption Posted By Office of Public Affairs Project Manager Janice Clark gives a safety briefing.

419

Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment Deeper  

Open Energy Info (EERE)

Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment Deeper Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment Deeper Temperature Gradient Drilling Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment Deeper Temperature Gradient Drilling Abstract Temperature gradient drilling has historically been a key tool in the exploration for geothermal resources in the Great Basin, USA, but regulatory, environmental, and accessibility issues, as well as the expense of drilling, are increasingly limiting its use. In cases where thermal groundwater is not overlain by near-surface cold aquifers, it is possible to augment temperature gradient drilling with temperatures measured from a 2-meter depth. We discuss the development of a rapid, efficient, and

420

Nissan and Centro partner to reduce energy cost 20% through improved metering  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Centro Inc. Nissan Centro Inc. Nissan 321 Hill Avenue 983 Nissan Drive Nashville, TN 37210 Smyrna, TN 37167 Business: Flow Control Distributor & Representative Business: Automobile Manufacturing Brad Davis Chris Goddard Territory Manager Environmental Engineer Phone: 615-255-2220 Phone: 615-459-1633 Email: bdavis@centromemphis.com Email: chris.goddard@nissan-usa.com Nissan and Centro partner to reduce energy cost 20% through improved metering Project Scope Nissan wanted to precisely measure consumption by department in their Smyrna facility. For low pressure natural gas applications, Nissan sought a simple, reliable metering device with no moving parts. Centro determined that the Aaliant Target Flow meter and the Fox Thermal Mass Flow meter would meet

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

The Intersection of Net Metering and Retail Choice: An Overview of Policy, Practice and Issues  

Broader source: Energy.gov [DOE]

In this report, the authors studied different facets of crediting mechanisms, and defined five different theoretical models describing different ways competitive suppliers and utilities provide net metering options for their customers. They then provided case studies to illustrate the models.

422

A Key Management Scheme for Secure Communications of Advanced Metering Infrastructure  

Science Journals Connector (OSTI)

Key management for secure communications of Advanced Metering Infrastructure is an unsolved problem until now. The ... proposing a key management scheme based on a hybrid-tree graph for AMI. The cyber security...

Jinshan Chen; Nian Liu; Wenxia Liu; Hong Luo

2011-01-01T23:59:59.000Z

423

Evaluation of a Close Coupled Slotted Orifice, Electrical Impedance, and Swirl Flow Meters for Multiphase Flow  

E-Print Network [OSTI]

homogenized flow for several pipe diameters downstream of the plate. This characteristic provides a homogeneous mixture at the inlet of the swirl meter, and impedance probe for gas volume fraction measurement (GVF). In order to evaluate the performance...

Cevik, Muhammet

2013-09-11T23:59:59.000Z

424

Too expensive to meter: the influence of transaction costs in transportation and communication  

Science Journals Connector (OSTI)

...the US Atomic Energy Commission, is...enjoy in their homes electrical energy too cheap to meter...of electricity consumption in the system...reduce electricity consumption or at least shift...the declining average (or per user...

2008-01-01T23:59:59.000Z

425

High Resolution Study of Micro-Meter Particle Detachment and Resuspension on Different Surfaces  

E-Print Network [OSTI]

In an effort to understand the resuspension phenomena, interactions of spherical micro-meter particles (glass beads (GB) and Stainless steel (SS)) were investigated experimentally on different surfaces (glass, ceramic, hardwood, metal and chemical...

Kassab, Asmaa 1983-

2012-08-16T23:59:59.000Z

426

Nissan North America: How Sub-Metering Changed the Way a Plant Does Business  

Broader source: Energy.gov [DOE]

This case study describes how Nissan North America uses sub-meters to measure a range of variables at its U.S. plants, including electricity and compressed air, and identify opportunities to reduce energy consumption.

427

The Impact of Rate Design and Net Metering on the Bill Savings from  

Open Energy Info (EERE)

Impact of Rate Design and Net Metering on the Bill Savings from Impact of Rate Design and Net Metering on the Bill Savings from Distributed Photovoltaics (PV) for Residential Customers in California Jump to: navigation, search Tool Summary LAUNCH TOOL Name: The Impact of Rate Design and Net Metering on the Bill Savings from Distributed Photovoltaics (PV) for Residential Customers in California Focus Area: Renewable Energy Topics: Best Practices Website: eetd.lbl.gov/ea/emp/reports/lbnl-3276e.pdf Equivalent URI: cleanenergysolutions.org/content/impact-rate-design-and-net-metering-b Language: English Policies: Deployment Programs DeploymentPrograms: Demonstration & Implementation This report analyzes the bill savings from photovoltaic (PV) deployment for residential customers of California's two largest electric utilities -

428

A field example of a gas orifice meter with debris-ridden liquid in mist flow  

SciTech Connect (OSTI)

A field example of debris-ridden liquids in an orifice meter is presented in this paper. Flow conditions in gas pipelines containing hydrocarbon liquids and particulate matter are discussed. Known effects on measurement of the presence of these materials in orifice meters is presented. By definition, gas measurement is accurate if performed on a clean and dry flow stream. This paper demonstrates the importance of removing as much liquid and debris as possible prior to measurement.

Chisholm, J.L.; Mooney, C.V. [Texas A and M Univ., Kingsville, TX (United States); Datta-Barua, L.; Feldmann, R.J.

1995-12-31T23:59:59.000Z

429

Metering and Monitoring Approaches for Verifying Energy Savings from Energy Conservation Retrofits: Experiences from the Field  

E-Print Network [OSTI]

METERING AND MONITORING APPROACHES FOR VERIFYING ENERGY SAVINGS FROM ENERGY CONSERVATION RETROFITS: EXPERIENCES FROM THE FIELD John R. McBride Charles J. Bohmer Roger H. Lippman Senior Scientist Senior Instrumentation Senior Instrumentation... drying process that operates at a constant energy level on a constant schedule are examples of this class of load. Engineering calculations without in-field metering and monitoring may be sufficient for this project class. Next in complexity...

McBride, J. R.; Bohmer, C. J.; Lippman, R. H.

430

The effects between two slotted plate flow meter under single, two, three components flow condition  

E-Print Network [OSTI]

THE INTERACTION BETWEEN A TWO SLOTTED PLATE FLOW METER UNDER ONE, TWO, OR THREE COMPONENT FLOW CONDITIONS A Thesis by SANG HYUN PARK Submitted to the Office of Graduate Studies of Texas A&M University in partial... fulfillment of the requirements for the degree of MASTER OF SCIENCE December 2004 Major Subject: Mechanical Engineering THE INTERACTION BETWEEN A TWO SLOTTED PLATE FLOW METER UNDER ONE, TWO, OR THREE COMPONENT FLOW...

Park, Sang Hyan

2005-02-17T23:59:59.000Z

431

Sub-metering to Electricity Use in Large-scale Commercial Buildings  

E-Print Network [OSTI]

;?#0;? Practice??Project example #0;?#0;? Use of data??Analysis Software Sub-metering and statistics to electricity use in commercial buildings 8 Method of sub-metering Whole electric power consumption of a building Hvac system Heating Circulating pump Oter... systems and equipments Equipments on Socket Special function room Electrically driven heating equipment Chiller Fan of cooling tower Chilled pump cooling pump Air hand unit Fresh air hand unit Fan coil unit Air conditioner Heating water system drinking...

Yuan, W.

2006-01-01T23:59:59.000Z

432

Evaluation of a slotted orifice plate flow meter using horizontal two phase flow  

E-Print Network [OSTI]

of MASTER OF SCIENCE December 2000 Major Subject: Mechanical Engineering EVALUATION OF A SLOTTED ORIFICE PLATE FLOW METER USING HORIZONTAL TWO PHASE FLOW A Thesis by ANITA ELENA FLORES Submitted to Texas A&M University in partial fulfillment...: Mechanical Engineering ABSTRACT Fvaluation of a Slotted Orifice Plate Flow Meter Using Horizontal Two Phase Flow. (December 2000) Anita Elena Flores, B. S. , Texas A&M I Jniversitv Chair of Advisory Committee: Dr. Herald L. Morrison In the past several...

Flores, Anita Elena

2012-06-07T23:59:59.000Z

433

Systematic mapping of Leaf Area Index across Canada using 250-meter MODIS data  

Science Journals Connector (OSTI)

An approach to generate a 250-meter Canada wide Leaf Area Index (LAI) map using 250-meter MODIS data is described. The full processing chain is introduced. The approach is based on intercalibration of Landsat and MODIS vegetation indices (VI's) combined with LAIVI's empirical relationships. Preliminary validation over two sites where field work was carried out shows promising results. Intercalibration of MODIS VI's before deriving LAI maps provides up to 65% improvement of the LAI overall accuracy.

Nadia Rochdi; Richard Fernandes

2010-01-01T23:59:59.000Z

434

Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Alaska American Samoa Arizona Arkansas California Colorado Connecticut Delaware District of Columbia Federal Florida Georgia Guam Hawaii Idaho Illinois Indiana Iowa Kansas...

435

OFFICE OF ACCOUTNING SERVICES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hawaii, American Samoa and Guam 135 IV Baltimore, San Francisco, Seattle 175 Chicago, Boston and International Cities 200 Alexandria & Arlington, VA, New York City, Washington DC...

436

Tax Credits, Rebates & Savings | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Alaska American Samoa Arizona Arkansas California Colorado Connecticut Delaware District of Columbia Federal Florida Georgia Guam Hawaii Idaho Illinois Indiana Iowa Kansas...

437

North American Energy Ministers Meeting  

Broader source: Energy.gov [DOE]

Washington The North American Energy Ministers met today, in response to the call of the North American Leaders, to advance an energy agenda that expands the continents leadership in energy, strengthens North American energy security, supports shared economic prosperity and environmental performance. This meeting builds upon a long, productive and successful history of trilateral North American collaboration on energy issues.

438

Development of the prototype Munitions Case Moisture Meter, Model ORNL-1  

SciTech Connect (OSTI)

There is a great need for a rapid and simple means of determining the moisture content in combustible cartridge case (ccc) munitions. Previous studies have demonstrated that accumulation of moisture in ccc rounds, such as the M829, leads to softening of the case wall and weakening of the adhesive joint. Moisture in the ccc can lead to incomplete combustion of the case upon firing the round. Currently, there are no facile methods for measuring the moisture content. A prototype portable meter for non-destructive and rapid estimation of moisture in ccc has been developed. The Munitions Case Moisture Meter Model ORNL-1 demonstrates the feasibility of developing an instrument based on the moisture dependence of dielectric properties, to measure moisture in ccc munitions in storage and in the field. These instruments are simple, inexpensive, lightweight, portable, low-power battery operated, and intrinsically safe. They provide nondestructive, noninvasive, and rapid measurements. Calibration data for the prototype are not available at this time. Therefore, calibration of the meter and the development of a scale reading directly moisture content in munitions rounds could not be completed. These data will be supplied by the US Army from its tests of the meter with actual munitions. However, experimental results on empty cccs in laboratory conditions demonstrate satisfactory performance of the instrument. Additional work is needed to bring the prototype to its optimum usefulness and accuracy for field measurements. This includes: Calibration of the meter scale with full-up munitions; Data and evaluation procedures to adjust the performance of the meter for different environmental conditions such as temperature and humidity; and Studies of the dielectric properties of moist ccc materials, as a function of frequency and temperature, are needed for adjustment of the meter for optimal performance.

Agouridis, D.C.; Gayle, T.M.; Griest, W.H.

1993-02-24T23:59:59.000Z

439

Development of the prototype Munitions Case Moisture Meter, Model ORNL-1. Final report  

SciTech Connect (OSTI)

There is a great need for a rapid and simple means of determining the moisture content in combustible cartridge case (ccc) munitions. Previous studies have demonstrated that accumulation of moisture in ccc rounds, such as the M829, leads to softening of the case wall and weakening of the adhesive joint. Moisture in the ccc can lead to incomplete combustion of the case upon firing the round. Currently, there are no facile methods for measuring the moisture content. A prototype portable meter for non-destructive and rapid estimation of moisture in ccc has been developed. The Munitions Case Moisture Meter Model ORNL-1 demonstrates the feasibility of developing an instrument based on the moisture dependence of dielectric properties, to measure moisture in ccc munitions in storage and in the field. These instruments are simple, inexpensive, lightweight, portable, low-power battery operated, and intrinsically safe. They provide nondestructive, noninvasive, and rapid measurements. Calibration data for the prototype are not available at this time. Therefore, calibration of the meter and the development of a scale reading directly moisture content in munitions rounds could not be completed. These data will be supplied by the US Army from its tests of the meter with actual munitions. However, experimental results on empty cccs in laboratory conditions demonstrate satisfactory performance of the instrument. Additional work is needed to bring the prototype to its optimum usefulness and accuracy for field measurements. This includes: Calibration of the meter scale with full-up munitions; Data and evaluation procedures to adjust the performance of the meter for different environmental conditions such as temperature and humidity; and Studies of the dielectric properties of moist ccc materials, as a function of frequency and temperature, are needed for adjustment of the meter for optimal performance.

Agouridis, D.C.; Gayle, T.M.; Griest, W.H.

1993-02-24T23:59:59.000Z

440

The American Association  

Science Journals Connector (OSTI)

... of the American Association for the Advancement of Science was held at St. Louis on December 26, 1903, to January 1. The address delivered by the president of the association, ...

1904-02-25T23:59:59.000Z

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

The great American garage  

E-Print Network [OSTI]

How does one explore the suburban home? Go in through the garage, of course. Sales, bands, suicides, and business startups: The suburban garage is the most culturally flexible space in the entire American domestic environment. ...

Miller, B. Alex (Brian Alex), 1977-

2004-01-01T23:59:59.000Z

442

3rd International symposium on fluid flow measurement effects of acoustic noise on orifice meters  

SciTech Connect (OSTI)

It is known that in-pipe acoustic noise can cause errors in orifice plate metering. The international metering community voted this topic as the highest priority for further research during a {open_quotes}working{close_quotes} held at N.T.I.S. in 1983. Most published work to date has been concerned with periodic, low frequency noise or pulsations, as encountered on reciprocating compressor installations where errors or their side effects may be readily noticed. Many orifice metering locations are, however, subject to high frequency noise emanating from control valves and centrifugal compressors. High frequency in-pipe noise is seldom suspected as a source of metering error and consequently it is a neglected topic. Square root error, which stems form the non-linear flow-differential pressure relationship of an orifice plate, has been well researched for low frequencies but the work has not been extended to high frequencies. To investigate this topic, high pressure studies at the British Gas Bishop Auckland Test Facility were carried out with a noise source (a pressure drop across a ball valve) and a 600 mm 0.4 {beta} orifice meter. These studies identified the effect of high frequency acoustic noise on orifice plate accuracy.

Norman, R.; Graham, P.; Drew, W.A. [Engineering Research Station, Newcastle Upon Tyne (United Kingdom)

1995-12-31T23:59:59.000Z

443

Design of a low-cost, high-resolution retrofit module for residential natural gas meters  

Science Journals Connector (OSTI)

Abstract There has been considerable interest in recent years in deploying smart meters in residential homes capable of distinguishing appliance-specific usage from whole-house consumption. Smart meters used in conjunction with algorithms that analyze usage data and other appliance attributes have been found to be a cost-effective and scalable approach. Based on this idea, the authors recently reported a laboratory-based solution for natural gas consisting of an encoder module retrofitted onto an existing residential gas meter. In this work, a detailed analysis of real gas consumption rates and patterns from common household appliances is performed and used to simulate the metering performance of a meter equipped with such an encoder module. The simulation is used to establish the optimal encoder resolution for a prototype encoder design that balances cost with performance. Improvements to the algorithms presented in the previous study to analyze the time-resolved data by deducing which appliance is using natural gas are also presented. The design, fabrication, and testing of a prototype encoder module is also presented.

M. Tewolde; J.C. Fritch; J.P. Longtin

2015-01-01T23:59:59.000Z

444

Analysis and methodology for measuring oxygen concentration in liquid sodium with a plugging meter  

SciTech Connect (OSTI)

Oxygen concentration in liquid sodium is a critical measurement in assessing the potential for corrosion damage in sodium-cooled fast reactors (SFRs). There has been little recent work on sodium reactors and oxygen detection. Thus, the technical expertise dealing with oxygen measurements within sodium is no longer readily available in the U.S. Two methods of oxygen detection that have been investigated are the plugging meter and the galvanic cell. One of the overall goals of the Univ. of Wisconsin's sodium research program is to develop an affordable, reliable galvanic cell oxygen sensor. Accordingly, attention must first be dedicated to a well-known standard known as a plugging meter. Therefore, a sodium loop has been constructed on campus in effort to develop the plugging meter technique and gain experience working with liquid metal. The loop contains both a galvanic cell test section and a plugging meter test section. Consistent plugging results have been achieved below 20 [wppm], and a detailed process for achieving effective plugging has been developed. This paper will focus both on an accurate methodology to obtain oxygen concentrations from a plugging meter, and on how to easily control the oxygen concentration of sodium in a test loop. Details of the design, materials, manufacturing, and operation will be presented. Data interpretation will also be discussed, since a modern discussion of plugging data interpretation does not currently exist. (authors)

Nollet, B. K.; Hvasta, M.; Anderson, M. [Univ. of Wisconsin-Madison, 1500 Engineering Dr., Madison, WI 53706 (United States)

2012-07-01T23:59:59.000Z

445

Performance of electric power meters and analyzers in adjustable-speed drive applications  

SciTech Connect (OSTI)

Electric adjustable-speed drives (ASDs) are increasingly used in heating, ventilating, and air-conditioning (HVAC) equipment due to the energy savings and comfort of operation they offer. Power electronic circuits that are employed in ASDs shape their input and output voltage and current waveforms, making them highly distorted from typical power-grid sinusoids. Accurate measurements of voltage, current, and power under nonsinusoidal conditions are essential for determining the efficiency of an HVAC unit and performing separation of losses between an ASD and an electric motor. That information is invaluable for HVAC equipment designers, manufacturers, and users. Three modern power meters and analyzers were tested to determine their accuracy with various nonsinusoidal waveforms applied. The meters were subjected to waveforms that are produced by the three most common ASD technologies used in air conditioners and heat pumps, namely, PWM induction, DC-brushless, and switched-reluctance drives. The tests were performed under field conditions and in a computer-controlled laboratory environment. The results obtained show that some meters can accurately measure electric power at the input to ASDs. However, the output power of ASDs for DC-brushless and switched-reluctance technology was not measured with acceptable accuracy by any of the tested meters. Possible reasons for meter inaccuracies and suggestions for performance improvement are given.

Czarkowski, D.; Domijan, A. Jr. [Univ. of Florida, Gainesville, FL (United States). Dept. of Electrical and Computer Engineering

1997-12-31T23:59:59.000Z

446

Afterschool Alliance American College Marketing, LLC  

E-Print Network [OSTI]

Afterschool Alliance American College Marketing, LLC American Express PAC Match American Heart Lehigh Valley Dental Society MEPAC National Collegiate Inventors & Innovators Alliance New York Life

Napier, Terrence

447

Microsoft PowerPoint - 03.2010_Metering Billing MDM America.pptx  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

METERING BILLING/MDM AMERICA METERING BILLING/MDM AMERICA Back-up Generation Sources (BUGS) Prepared by Steve Pullins March 9, 2010 Metering, Billing/MDM America - San Diego, CA This material is based upon work supported by the Department of Energy under Award Number DE- Department of Energy under Award Number DE AC26-04NT41817 This presentation was prepared as an account of work sponsored by an agency of This presentation was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed or represents

448

The "Other" Energy in Buildings: Wireless Power Metering of Plug-in  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The "Other" Energy in Buildings: Wireless Power Metering of Plug-in The "Other" Energy in Buildings: Wireless Power Metering of Plug-in Devices in Building 90 and Homes Speaker(s): Steven Lanzisera Date: June 17, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Anita Estner Miscellaneous and electronic devices consume about one-third of the primary energy used in U.S. buildings, and their energy use is increasing faster than other end-uses. Although these devices have been studied for 30 years, they are not as well understood as the other end-uses due to their great variety and difficulty in collecting representative energy data for them. This talk describes a method for collecting device-level energy use data for these devices using a relatively low-cost wireless mesh networking technology. Over 600 meters were deployed across B90 and three homes to

449

Cost benefit analysis for the implementation of smart metering with pilot  

Open Energy Info (EERE)

benefit analysis for the implementation of smart metering with pilot benefit analysis for the implementation of smart metering with pilot project (Smart Grid Project) Jump to: navigation, search Project Name Cost benefit analysis for the implementation of smart metering with pilot project Country Slovakia Coordinates 48.669025°, 19.699024° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":48.669025,"lon":19.699024,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

450

Five Million Smart Meters Installed Nationwide is Just the Beginning of  

Broader source: Energy.gov (indexed) [DOE]

Five Million Smart Meters Installed Nationwide is Just the Five Million Smart Meters Installed Nationwide is Just the Beginning of Smart Grid Progress Five Million Smart Meters Installed Nationwide is Just the Beginning of Smart Grid Progress June 13, 2011 - 1:55pm Addthis A 21st Century Grid includes increasing the overall efficiency of our generating, transmission and distribution system to facilitate the growth of renewable energy sources. | Energy Department Image A 21st Century Grid includes increasing the overall efficiency of our generating, transmission and distribution system to facilitate the growth of renewable energy sources. | Energy Department Image Secretary Chu Secretary Chu Former Secretary of Energy What does this mean for me? We must have an efficient electricity infrastructure to compete in the global economy.

451

Five Million Smart Meters Installed Nationwide is Just the Beginning of  

Broader source: Energy.gov (indexed) [DOE]

Five Million Smart Meters Installed Nationwide is Just the Five Million Smart Meters Installed Nationwide is Just the Beginning of Smart Grid Progress Five Million Smart Meters Installed Nationwide is Just the Beginning of Smart Grid Progress June 13, 2011 - 1:55pm Addthis A 21st Century Grid includes increasing the overall efficiency of our generating, transmission and distribution system to facilitate the growth of renewable energy sources. | Energy Department Image A 21st Century Grid includes increasing the overall efficiency of our generating, transmission and distribution system to facilitate the growth of renewable energy sources. | Energy Department Image Secretary Chu Secretary Chu Former Secretary of Energy What does this mean for me? We must have an efficient electricity infrastructure to compete in the global economy.

452

"I'd Like to Check Out Two Books, One DVD, and One Electrical Meter,  

Broader source: Energy.gov (indexed) [DOE]

"I'd Like to Check Out Two Books, One DVD, and One Electrical "I'd Like to Check Out Two Books, One DVD, and One Electrical Meter, Please." "I'd Like to Check Out Two Books, One DVD, and One Electrical Meter, Please." December 8, 2009 - 10:01am Addthis John Lippert Yesterday I wrote about my experience using a digital electrical meter at home. Today I'll discuss what I'm doing with promoting their use in my home town. According to one popular environmental Web site, there are a number of libraries providing free loan of these or similar devices, including: The Ottawa Public Library in Ottawa, Canada; the Brown County Library in Green Bay, Wisconsin; the Westport, Connecticut Public Library; hundreds of public libraries in Maine; and libraries in Gothenburg, Sweden. That sounded like a great idea, so I visited my local library to explore

453

Results mixed from pulsating flow tests of orifice-plate meters  

SciTech Connect (OSTI)

This paper reports that laboratory tests on several commercially available orifice-plate meters for use in pulsating flow indicate that none yields acceptable accuracy. These tests suggested, however, that if the objective of monitoring pulsating flow is to indicate or quantify pulsation magnitudes for comparisons, then at least two instruments are acceptable. Use of such meters, particularly in low flow rate gathering systems, can be a viable alternative to attempting to reduce the intensity (amplitude and frequency) of pulsation by expensive installation and maintenance of chokes and bottles. Phillips Petroleum Co. set out to find a meter that would be sensitive enough to measure pulsating hydrocarbon flows with acceptable accuracy using the orifice plate. Several orifice measurement systems were simultaneously investigated at the Southwest Research Institute, San Antonio (SwRI).

Arasi, J.A. (Phillips Petroleum Co., Tananger (Norway))

1992-10-05T23:59:59.000Z

454

Demand Response and Smart Metering Policy Actions Since the Energy Policy  

Open Energy Info (EERE)

form form View source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit with form History Facebook icon Twitter icon » Demand Response and Smart Metering Policy Actions Since the Energy Policy Act of 2005: A Summary for State Officials Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Demand Response and Smart Metering Policy Actions Since the Energy Policy Act of 2005: A Summary for State Officials Focus Area: Energy Efficiency, - Utility Topics: Socio-Economic Website: www.demandresponsesmartgrid.org/Resources/Documents/Final_NCEP_Report_ Equivalent URI: cleanenergysolutions.org/content/demand-response-and-smart-metering-po Language: English Policies: Regulations

455

Microsoft Word - CX-TaylorFlatsSubstationMeterFY13_WEB.docx  

Broader source: Energy.gov (indexed) [DOE]

25, 2013 25, 2013 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Cleareance Memorandum Bob Trisman Electrical Engineer - TEP-CSB-1 Proposed Action: Revenue meter replacement at Franklin County Public Utility District's (PUD) Taylor Flats Substation PP&A Project No: 2608 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.7 Electronic Equipment Location: Franklin County, Washington. Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to remove the existing equipment and replace it with a new JEMSTAR revenue meter within BPA's existing meter rack inside Franklin County PUD's Taylor Flats Substation. No ground disturbance or alteration to the control house would occur.

456

Gout in African Americans  

Science Journals Connector (OSTI)

AbstractPurpose African Americans have a substantially higher prevalence of risk factors for gout than Caucasians. The aim of the present study was to compare the risk for incident gout among African Americans and Caucasians. Methods Incidence rates of physician-diagnosed gout among 11,559 Caucasian men and 931 African American men aged 35 to 57 years and at high cardiovascular risk, observed for 7 years as a part of the Multiple Risk Factor Intervention Trial, were analyzed. Cox regression models were used to account for potential confounding by age, body mass index, diuretic use, hypertension and diabetes status, aspirin and alcohol consumption, and kidney disease. Results At baseline, after accounting for risk factors, African Americans had a 14% lower prevalence of hyperuricemia than Caucasians. Incidence of gout increased with increasing prevalence of risk factors in both Caucasians and African Americans. Ethnic disparities in incidence rates were most apparent among those without other risk factors for gout. In separate Cox regression models, after accounting for risk factors, African American ethnicity was associated with a hazard ratio of 0.78 (95% confidence interval [CI], 0.66-0.93) for physician-diagnosed gout and 0.88 (95% CI, 0.85-0.90) for incident hyperuricemia. Significant interactions were observed; the association was the strongest (hazard ratio 0.47; 0.37-0.60). These associations were unaffected by addition of serum urate as a covariate or by using alternate case definitions for gout. Conclusions After accounting for the higher prevalence of risk factors, African American ethnicity is associated with a significantly lower risk for gout and hyperuricemia compared with Caucasian ethnicity.

Eswar Krishnan

2014-01-01T23:59:59.000Z

457

Advanced Metering Plan for Monitoring Energy and Potable Water Use in PNNL EMS4 Buildings  

SciTech Connect (OSTI)

This updated Advanced Metering Plan for monitoring whole building energy use in Pacific Northwest National Laboratory (PNNL) EMS4 buildings on the PNNL campus has been prepared in accordance with the requirements of the Energy Policy Act of 2005 (EPAct 2005), Section 103, U.S. Department of Energy (DOE) Order 430.2B, and Metering Best Practices, A Guide to Achieving Utility Resource Efficiency, Federal Energy Management Program, October 2007 (Sullivan et al. 2007). The initial PNNL plan was developed in July 2007 (Olson 2007), updated in September 2008 (Olson et al. 2008), updated in September 2009 (Olson et al. 2009), and updated again in August 2010 (Olson et al. 2010).

Pope, Jason E.; Olson, Norman J.; Berman, Marc J.; Schielke, Dale R.

2011-08-17T23:59:59.000Z

458

Monitoring the Thermal Power of Nuclear Reactors with a Prototype Cubic Meter Antineutrino Detector  

E-Print Network [OSTI]

In this paper, we estimate how quickly and how precisely a reactor's operational status and thermal power can be monitored over hour to month time scales, using the antineutrino rate as measured by a cubic meter scale detector. Our results are obtained from a detector we have deployed and operated at 25 meter standoff from a reactor core. This prototype can detect a prompt reactor shutdown within five hours, and monitor relative thermal power to three percent within seven days. Monitoring of short-term power changes in this way may be useful in the context of International Atomic Energy Agency's (IAEA) Reactor Safeguards Regime, or other cooperative monitoring regimes.

A. Bernstein; N. S. Bowden; A. Misner; T. Palmer

2008-04-30T23:59:59.000Z

459

Constancy of built-in luminance meter measurements in diagnostic displays  

SciTech Connect (OSTI)

Purpose: Liquid crystal displays used to interpret medical images are often equipped with built-in luminance meters to evaluate luminance response and Grayscale Standard Display Function conformance. This work evaluates agreement between luminance reported by the built-in meters and external measurements. Methods: The white level luminance was measured using a built-in meter and an external meter for 93 primary review workstations (Models MFGD 3420 and MDCG 3120-CB) with between 117 and 49?336 backlight hours (BLH). Measured luminance values were compared viat-test for displays with less than 25?000 BLH and those with more than 25?000 BLH. Bias between meters was also evaluated. Changes in luminance uniformity with increasing backlight hours were explored by determining the maximum luminance deviation (MLD) for subsets of these displays with less than 800 BLH and greater than 35?000 BLH. Results: The mean difference between built-in and external luminance measurements was 5.84% and 38.92% for displays with less than 25?000 and greater than 25?000 BLH, respectively, with a statistically significant difference in the means (p < 0.001). For displays with low BLH, a statistically significant bias was observed (p < 0.001) between built-in and external measurements. A high degree of correlation was observed between measurements made with two separate external meters (r = 0.999). The mean MLD was 9.5% and 11.2% for MDCG 3120-CB displays with less than 800 and greater than 35?000 BLH, respectively. The difference in the mean values was not statistically significant (p < 0.001). Conclusions: Disagreement between the white level luminance measured using the built-in and external meter increased with BLH. Consequently, reliance on values reported by the built-in luminance meter may result in a reduction in image contrast with time. Recommendations have been proposed regarding luminance response testing and corrective action for failing displays.

Silosky, M., E-mail: michael.silosky@ucdenver.edu; Marsh, R. M. [Department of Radiology, University of Colorado, School of Medicine Aurora, Colorado 80045 (United States)] [Department of Radiology, University of Colorado, School of Medicine Aurora, Colorado 80045 (United States)

2013-12-15T23:59:59.000Z

460

Currents and waters of the upper 1200 meters of the southwestern Gulf of Mexico  

E-Print Network [OSTI]

CURRENTS AND WATERS OF THE UPPER 1200 METERS OF THE SOUTHWESTERN GULF OF MEXICO A Thesis by ALBERTO MARIANO VAZQUEZ DE LA CERDA Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree... of MASTER OF SCIENCE August 1975 Major Subject: Oceanography CURRENTS AND WATERS OF THE UPPER 1200 METERS OF THE SOUTHWESTERN GULF OP MEXICO A Thesis by ALBERTO MARIANO VAZ0UEZ DE LA CERDA Approved as to style and content by: , , l (Chairman...

Vasquez de la Cerda, Alberto Mariano

1975-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Thirty-meter digital elevation models (DEMs) produced by the U.S. Geological Survey (USGS) are widely available and com-  

E-Print Network [OSTI]

Abstract Thirty-meter digital elevation models (DEMs) produced by the U.S. Geological Survey (USGS, and slope classes gen- erated from sample 10-meter drainage-enforced (DE) DEMs and 30-meter DEMs. We found increasing resolution from 30 meters to 10 me- ters, particularly in flatter terrain; (2) streams and HU

462

Meter Eligibility Listing Procedure Updated 6/2/14 The California Solar Initiative (CSI) is for all market segments with the exception of New  

E-Print Network [OSTI]

Meter Eligibility Listing Procedure Updated 6/2/14 The California Solar on the accuracy of the meter there are two different routes to eligibility listing: Nonrevenue grade meters: 1. The meter must be selfcertified by the manufacturer to an accuracy of +/ 5%. 2. Fill out

463

Chapter 9, Metering Cross-Cutting Protocols: The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures  

Broader source: Energy.gov (indexed) [DOE]

9: Metering Cross- 9: Metering Cross- Cutting Protocols Dan Mort, ADM Associates, Inc. Subcontract Report NREL/SR-7A30-53827 April 2013 The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures 9 - 1 Chapter 9 - Table of Contents 1 Introduction ............................................................................................................................ 3 2 Metering Application and Considerations ............................................................................. 4 2.1 Identifying Scope ............................................................................................................. 4 2.2 Ensuring Precision and Verification ................................................................................ 4

464

North American Electric Reliability Corporation Interconnections...  

Broader source: Energy.gov (indexed) [DOE]

Interconnections North American Electric Reliability Corporation Interconnections Map of the North American Electric Reliability Corporation Interconnection showing the Eastern,...

465

NORTH AMERICAN ELECTRIC RELIABILITY COUNCIL: Preliminary Disturbance...  

Broader source: Energy.gov (indexed) [DOE]

NORTH AMERICAN ELECTRIC RELIABILITY COUNCIL: Preliminary Disturbance Report NORTH AMERICAN ELECTRIC RELIABILITY COUNCIL: Preliminary Disturbance Report The following information...

466

Thermal Energy Measurement with Tangential Paddlewheel Flow Meters: Summary of Experimental Results and in-situ Diagnostics  

E-Print Network [OSTI]

paddlewheel flow meters, and several new methods for in-situ diagnostic measures for ascertaining whether or not a flow meter is experiencing fluctuating flow conditions or if a flow meter is suffering a degraded signal due to shaft wear. INTRODUCTION Flow... section where it passes across the candidate sensor that is placed in the inter-changeable test section, through the orifice plate and finally into the is combined with Btu meter the threshold can be much higher than the published threshold of the flow...

Haberl, J. S.; Watt, J. B.

1994-01-01T23:59:59.000Z

467

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California  

E-Print Network [OSTI]

net metering, and policies for supporting solar deployment.Policy 36 (9), 3266-3277. MRW and Associates, 2007. Solar PV

Darghouth, Naim R.

2012-01-01T23:59:59.000Z

468

AMERICAN STATISTICAL ASSOCIATION (ASA)  

U.S. Energy Information Administration (EIA) Indexed Site

AMERICAN STATISTICAL ASSOCIATION (ASA) AMERICAN STATISTICAL ASSOCIATION (ASA) MEETING OF THE COMMITTEE ON ENERGY STATISTICS WITH THE ENERGY INFORMATION ADMINISTRATION (EIA) Washington, D.C. Friday, April 29, 2005 COMMITTEE MEMBERS: NICOLAS HENGARTNER, Chair Los Alamos National Laboratory MARK BERNSTEIN RAND Corporation CUTLER CLEVELAND Center for Energy and Environmental Studies JAE EDMONDS Pacific Northwest National Laboratory MOSHE FEDER Research Triangle Institute BARBARA FORSYTH Westat WALTER HILL St. Mary's College of Maryland NEHA KHANNA Binghamton University NAGARAJ K. NEERCHAL University of Maryland Baltimore County SUSAN M. SEREIKA University of Pittsburgh DARIUS SINGPURWALLA LECG RANDY R. SITTER Simon Fraser University ALSO PRESENT: MARGOT ANDERSON Energy Information Administration ALSO PRESENT (CONT'D):

469

Central American electrical interconnection  

SciTech Connect (OSTI)

A technical cooperation grant of $2.25 million, designed to strengthen the capacity of Central American countries to operate their regional interconnected electrical system, was announced by the Inter-American Development Bank (IDB). The grant, extended from the banks Fund for Special Operations, will help improve the capacity of the regions electric power companies to achieve economical, safe operation of the interconnected electric power systems. The funds will also be used to finance regional studies of the accords, procedures, regulations, and supervisory mechanisms for the system, as well as program development and data bases.

Not Available

1988-12-01T23:59:59.000Z

470

AMERICAN STATISTICAL ASSOCIATION  

U.S. Energy Information Administration (EIA) Indexed Site

AMERICAN STATISTICAL ASSOCIATION AMERICAN STATISTICAL ASSOCIATION + + + + + COMMITTEE ON ENERGY STATISTICS + + + + + FALL MEETING + + + + + FRIDAY OCTOBER 17, 2003 + + + + + The Committee met in Room 8E089 in the Forrestal Building, 1000 Independence Avenue, S.W., Washington, D.C., at 8:30 a.m., Jay Breidt, Chair, presiding. PRESENT F. JAY BREIDT Chair NICOLAS HENGARTNER Vice Chair JOHNNY BLAIR Committee Member MARK BURTON Committee Member JAE EDMONDS Committee Member MOSHE FEDER Committee Member JAMES K. HAMMITT Committee Member NEHA KHANA Committee Member NAGARAJ K. NEERCHAL Committee Member

471

'Prawns per square meter of available substrate. 'A total of eight laboratory tanks.  

E-Print Network [OSTI]

'Prawns per square meter of available substrate. 'A total of eight laboratory tanks. 5 5 3.8 4 (80 m deep) Net pen 1 Net pen 2 Net pen 3 Laboratory tanks' and captured, wild females. The females were either in three net pens, eight laboratory tanks, or in a benthic cage. The net pens were constructed

472

Radiation dose-rate meter using an energy-sensitive counter  

DOE Patents [OSTI]

A radiation dose-rate meter is provided which uses an energy-sensitive detector and combines charge quantization and pulse-rate measurement to monitor radiation dose rates. The charge from each detected photon is quantized by level-sensitive comparators so that the resulting total output pulse rate is proportional to the dose-rate.

Kopp, Manfred K. (Oak Ridge, TN)

1988-01-01T23:59:59.000Z

473

An investigation of effects of flow conditioning on straight tube Coriolis meter  

E-Print Network [OSTI]

Coriolis meter, despite being very accurate in single phase conditions, fails to accurately measure two-phase flows. It poses a complex fluid-structure interaction problem in case of two-phase operation; there is a scarcity of theoretical models...

Shukla, Shashank

2009-05-15T23:59:59.000Z

474

MICRO-METER MEASUREMENT OF CRACKS TO COMPARE BLAST AND ENVIRONMENTAL EFFECTS.  

E-Print Network [OSTI]

to development of a new approach to vibration monitoring called autonomous crack measurement (ACM vibration time histories. Measurements reported herein show that weather- induced response of cracksMICRO-METER MEASUREMENT OF CRACKS TO COMPARE BLAST AND ENVIRONMENTAL EFFECTS. Charles H Dowding

475

Embedded Firmware Diversity for Smart Electric Meters Stephen McLaughlin, Dmitry Podkuiko, Adam Delozier  

E-Print Network [OSTI]

.g., consumer-generated wind and solar energy. Smart meters are the consumer conduit to the grid. Re- placing in use today and hundreds of millions more to be deployed in the next few years. These low-cost ( $50 systems offers substantial benefits for society; increased efficien- cies and information availability can

McDaniel, Patrick Drew

476

Too expensive to meter: the influence of transaction costs in transportation and communication  

Science Journals Connector (OSTI)

...Strauss, the Chairman of the US Atomic Energy Commission, is often remembered for a...children will enjoy in their homes electrical energy too cheap to meter, . It is not too much...England. Report by the Comptroller and Auditor General. HC 677 Session 2005-2006...

2008-01-01T23:59:59.000Z

477

Energy-Harvesting Thermoelectric Sensing for Unobtrusive Water and Appliance Metering  

E-Print Network [OSTI]

in homes and buildings pro- vides a promising technique for addressing the unmaintain- able energy's energy footprint. A myriad of sensor designs and systems collect data on partic- ular building aspects Introduction Detailed energy metering in buildings allows homeown- ers, tenants, and building managers

Dutta, Prabal

478

Payment Matters? - An Exploratory Study into the Pre-Payment Electricity Metering  

E-Print Network [OSTI]

In this paper we look at the role of pre-payment (in the context of prepayment metering) for household electricity consumption. Using a matching approach, we find that households paying their electricity up-front tend to consume no less electricity...

Brutscher, Philipp-Bastian

2011-02-10T23:59:59.000Z

479

Design rules for pumping and metering of highly viscous fluids in microfluidics  

E-Print Network [OSTI]

Design rules for pumping and metering of highly viscous fluids in microfluidics Sarah L. Perry.1039/c0lc00035c The use of fluids that are significantly more viscous than water in microfluidics has a theoretical treatment for the flow of highly viscous fluids in deforming microfluidic channels, particularly

Kenis, Paul J. A.

480

Feasibility Study of Developing a Virtual Chilled Water Flow Meter at Air Handling Unit Level  

E-Print Network [OSTI]

In this paper, a virtual Air handling unit (AHU) level water flow meter is explored by using a control valve as a measurement device. The flow through the valve is indirectly calculated using differential pressure over both the valve and its...

Song, L.; Swamy, A.; Shim, G.

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "metering american samoa" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Bio-Rad Laboratories q u a l i t y c o n t r o l Meter TraxTM  

E-Print Network [OSTI]

Bio-Rad Laboratories q u a l i t y c o n t r o l Meter TraxTM Control #12;q u a l i t y c o n t r o l Meter TraxTM Control Quality Control Meter TraxTM is an ideal quality control for point-of-care meters. It is available in easy-to-use dropper bottles and has assigned values for many meters

Rodriguez, Carlos

482

The First Americans  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Americans Americans Nature Bulletin No. 360-A November 29, 1969 Forest Preserve District of Cook County George W. Dunne, President Roland F. Eisenbeis, Supt. of Conservation THE FIRST AMERICANS When the Norsemen and then Columbus "discovered" America they found people here -- people with bronze skins and straight black hair. Because he thought he had sailed across the world and found a sea passage to India. Columbus called these people "Indios". He was wrong but we still call them Indians. It is now generally accepted by scientists that the first humans arrived on this American continent some thirty or forty thousand years ago. It is believed that they came from Asia, across what we call Bering Strait. The distance from the islands at the westernmost tip of Alaska to the easternmost tip of Siberia is only 59 miles. In clear weather you can see from land to land. In ancient times there may have been a bridge of solid ice between the two shores, or there might have been an actual land connection between the two continents. But even if there were a 5-mile gap of water it could have been crossed in primitive canoes by hungry people hunting for game. Hunger has been the mainspring of civilization.

483

Association of American Geographers  

Science Journals Connector (OSTI)

... THE thirtieth annual meeting of the Association of American Geographers was held on December 2628, at North-western University, Evanston, Illinois. In the three day session fifty ... six in urban geography. The remainder represented a diversity of subjects. The afternoon of December 26 was devoted to the general subject of Conventionalizing Geographic Investigation and Presentation. The ...

1934-01-27T23:59:59.000Z

484

CX-007384: Categorical Exclusion Determination | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

4: Categorical Exclusion Determination 4: Categorical Exclusion Determination CX-007384: Categorical Exclusion Determination Improving Recycling Capacity and Solid Waste Education in American Samoa CX(s) Applied: B1.31, B1.35, A9 Date: 12/21/2011 Location(s): American Samoa Offices(s): Golden Field Office The U.S. Department of Energy (DOE) provided funding to the American Samoa Government Territorial Energy Office under DOE's American Recovery and Reinvestment Act of 2009 Energy Efficiency and Conservation Block Grant (EECBG) Program. The American Samoa Government Territorial Energy Office is proposing to use $500,000 of that funding for the "Improving Recycling Capacity and Solid Waste Education in American Samoa" project. CX-007384.pdf More Documents & Publications CX-009566: Categorical Exclusion Determination

485

Net Metering  

Broader source: Energy.gov (indexed) [DOE]

No limit specified (Board of Public Utilities may limit to 2.5% of peak demand) 9 * California o Net Excess Generation (NEG): Credited to customer's next bill at retail rate. - At...

486

Remote metering  

E-Print Network [OSTI]

in order to disoharge it after each oharge. L oontaot caking relay R was next placed in the oircuit ss shown on page 9, pig. 3, to discharge condenser 5 after each impulse. Indications on voltmeter I were now found. to be proportional to the speed... arrangements, the circuit as shown on page 11 was evolve4. ihe use of mepeating coils and a grounded circuit released the telephone circuit for telephone servioe, while placing the relay R as shown made the cal- ibrated circuit a looal oircuit, eliminate4...

Ingram, Henry Lee

2012-06-07T23:59:59.000Z

487

Microsoft Word - CX-McLoughlin_Meter_23July2013.doc  

Broader source: Energy.gov (indexed) [DOE]

3 3 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Joan Kendall Project Manager -TERR-3 Proposed Action: McLoughlin Substation metering panel ownership transfer Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.24 Property transfers Location: Clackamas County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to transfer ownership of two interchange metering panels and associated hardware, which are located in the McLoughlin Substation control house, to Portland General Electric (PGE). In June 2013, BPA started removal of a transformer from the McLoughlin Substation to minimize the BPA footprint within the larger PGE

488

METER-SIZED MOONLET POPULATION IN SATURN'S C RING AND CASSINI DIVISION  

SciTech Connect (OSTI)

Stellar occultations observed by the Cassini Ultraviolet Imaging Spectrograph reveal the presence of transparent holes a few meters to a few tens of meters in radial extent in otherwise optically thick regions of the C ring and the Cassini Division. We attribute the holes to gravitational disturbances generated by a population of {approx}10 m boulders in the rings that is intermediate in size between the background ring particle size distribution and the previously observed {approx}100 m propeller moonlets in the A ring. The size distribution of these boulders is described by a shallower power-law than the one that describes the ring particle size distribution. The number and size distribution of these boulders could be explained by limited accretion processes deep within Saturn's Roche zone.

Baillie, Kevin; Colwell, Joshua E. [Department of Physics, University of Central Florida, Orlando, FL 32816-2385 (United States); Esposito, Larry W. [Laboratory for Atmospheric and Space Physics, University of Colorado at Boulder, 392 UCB, Boulder, CO 80309-0392 (United States); Lewis, Mark C., E-mail: kevin.baillie@cea.fr [Department of Computer Science, Trinity University, One Trinity Place, San Antonio, TX 78212-7200 (United States)

2013-06-01T23:59:59.000Z

489

Design of a speed meter interferometer proof-of-principle experiment  

E-Print Network [OSTI]

The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of development are being pursued to reach this goal, focusing both on modifications of the well-established Michelson detector configuration and development of different detector topologies. In this paper, we present the design of the world's first Sagnac speed meter interferometer which is currently being constructed at the University of Glasgow. With this proof-of-principle experiment we aim to demonstrate the theoretically predicted lower quantum noise in a Sagnac interferometer compared to an equivalent Michelson interferometer, to qualify Sagnac speed meters for further research towards an implementation in a future generation large scale gravitational wave detector, such as the planned Einstein Telescope observatory.

C. Grf; B. W. Barr; A. S. Bell; F. Campbell; A. V. Cumming; S. L. Danilishin; N. A. Gordon; G. D. Hammond; J. Hennig; E. A. Houston; S. H. Huttner; R. A. Jones; S. S. Leavey; H. Lck; J. Macarthur; M. Marwick; S. Rigby; R. Schilling; B. Sorazu; A. Spencer; S. Steinlechner; K. A. Strain; S. Hild

2014-09-11T23:59:59.000Z

490

The SNL100-01 blade : carbon design studies for the Sandia 100-meter blade.  

SciTech Connect (OSTI)

A series of design studies to investigate the effect of carbon on blade weight and performance for large blades was performed using the Sandia 100-meter All-glass Baseline Blade design as a starting point. This document provides a description of the final carbon blade design, which is termed as SNL100-01. This report includes a summary of the design modifications applied to the baseline all-glass 100-meter design and a description of the NuMAD model files that are made publicly available. This document is intended primarily to be a companion document to the distribution of the NuMAD blade model files for SNL100-01.

Griffith, Daniel Todd

2013-02-01T23:59:59.000Z

491

Building an American Economy to Last: American Competiveness in  

Broader source: Energy.gov (indexed) [DOE]

Building an American Economy to Last: American Competiveness in Building an American Economy to Last: American Competiveness in Manufacturing Building an American Economy to Last: American Competiveness in Manufacturing August 16, 2012 - 9:20am Addthis Saving Energy and Resources 1 of 4 Saving Energy and Resources Thanks to additive manufacturing technology, Oak Ridge National Laboratory was able to fabricate a robotic hand with less energy use and material waste. The novel, lightweight, low-cost fluid powered hand was selected for a 2012 R&D 100 award. | Photo courtesy of Oak Ridge National Laboratory. Partnering with Industry 2 of 4 Partnering with Industry The Energy Department's Manufacturing Demonstration Facility at Oak Ridge National Laboratory includes an array of state-of-the-art additive manufacturing capabilities, allowing researchers and industry to develop

492

Building an American Economy to Last: American Competiveness in  

Broader source: Energy.gov (indexed) [DOE]

Building an American Economy to Last: American Competiveness in Building an American Economy to Last: American Competiveness in Manufacturing Building an American Economy to Last: American Competiveness in Manufacturing August 16, 2012 - 9:20am Addthis Saving Energy and Resources 1 of 4 Saving Energy and Resources Thanks to additive manufacturing technology, Oak Ridge National Laboratory was able to fabricate a robotic hand with less energy use and material waste. The novel, lightweight, low-cost fluid powered hand was selected for a 2012 R&D 100 award. | Photo courtesy of Oak Ridge National Laboratory. Partnering with Industry 2 of 4 Partnering with Industry The Energy Department's Manufacturing Demonstration Facility at Oak Ridge National Laboratory includes an array of state-of-the-art additive manufacturing capabilities, allowing researchers and industry to develop

493

The American Elm  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Elm Elm Nature Bulletin No. 279-A October 21, 1967 Forest Preserve District of Cook County Richard B. Ogilvie, President Roland F. Eisenbeis, Supt. of Conservation THE AMERICAN ELM For three centuries, the stately graceful American Elm -- "the tree that like a fountain rises" -- has been our favorite shade tree, and around it have grown some of our finest traditions. The early colonists found huge patriarchs, which reminded them of the magnificent English Elms, and they planted seedlings to shade their homes and village commons. Today, innumerable New England roadways are lined with giant elms, their great arching limbs forming canopies like a cathedral roof. When the pioneers moved westward, they found this tree everywhere in the bottomlands and on low fertile hills. NOW, throughout the Middle West -- even in prosaic prairie towns -- streets and public buildings are shaded and given character by beautiful elms.

494

NORTH AMERICAN WATER OFFICE  

Broader source: Energy.gov (indexed) [DOE]

NORTH AMERICAN WATER OFFICE NORTH AMERICAN WATER OFFICE P.O. Box 174 Lake Elmo, MN 55042 Phone: (612) 770-3861 Fax: (612) 770-3976 January 30, 1998 US Department of Energy Office of General Council GC-52 1000 Independence Ave. SW Washington DC 20585 RE: Preparation of Report to Congress on Price-Anderson Act Dear Office of General Council: The Price Anderson Act should be eliminated. The Price Anderson Act assumes that the encouragement and growth of the commercial nuclear industry is in the public interest. It is not. Rational evaluation of the commercial nuclear industry forces the conclusion that the Price Anderson Act simply shields the commercial nuclear industry from costs that it would otherwise, in a fair market setting, be forced to internalize and pay. Price Anderson amounts to

495

AMERICAN HERITAGE OF  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AMERICAN HERITAGE OF AMERICAN HERITAGE OF raven 10~ SUMMER 1995 $d.OU VOLUME 11/NU~IBH;R 1 i Y .rt: r "~ ~:rih a ~~ to Invent * Tf~e~'' ~ °of _._.. , _._~.__ ~y~,: ..~_, ec no o~ r HE TOM OMB FIFTY YEARS AGO THIS SUNI~fER, THE WORLD WAS changed forever when the first nuclear bomb ex- ploded above the New Mexico desert and then bombs were dropped on the cities of Hiroshima and Nagasaki, Japan. The moral, psychological, and geopolitical ramifications of this most powerful and revolution- ary of all technologies and its use have been matters of universal con- cern ever since. They will undoubtedly be the subject of particularly intense discussion this summer. Invention ~ Technology's contribution is a look at the anniversary from the magazine's unique perspective, examining the making of the

496

Watching an uniformly moving source of light using a telescope and a frequency-meter  

E-Print Network [OSTI]

We propose a scenario that involves a stationary observer who detects a point like source of light moving with constant velocity at a constant altitude, using a telescope and a frequency-meter. We derive a formula for the angular velocity at which we should rotate the axis of the telescope and a formula that relates the proper period at which the source emits successive wave crests and the proper period at which the stationary observer receives them

Bernhard Rothenstein; Ioan Damian

2005-04-04T23:59:59.000Z

497

Property:OpenEI/UtilityRate/UseNetMetering | Open Energy Information  

Open Energy Info (EERE)

UseNetMetering UseNetMetering Jump to: navigation, search This is a property of type Boolean. Name: Use Net Metering Pages using the property "OpenEI/UtilityRate/UseNetMetering" Showing 25 pages using this property. (previous 25) (next 25) 0 0000827d-84d0-453d-b659-b86869323897 + false + 000086db-7a5e-4356-9c57-c912f7d1622e + false + 0003a8b3-04b9-4ecb-b06d-6022e7f0f009 + false + 000470c7-df04-47aa-bdd2-d70f0a2c52b3 + false + 000b6dfa-a541-428a-9029-423006e22a34 + false + 000db36e-b548-43e7-a283-d37ecc77cef1 + false + 000e60f7-120d-48ab-a1f9-9c195329c628 + false + 00101108-073b-4503-9cd4-01769611c26f + false + 001361ca-50d2-49bc-b331-08755a2c7c7d + false + 00141c43-a74b-4768-aacc-47357b9e7858 + false + 0015a129-b638-4018-8e5b-aa54dd07b223 + false + 0016f771-cda9-4312-afc2-63f10c8d8bf5 + false +

498

Stakeholder Engagement and Outreach: Offshore 90-Meter Wind Maps and Wind  

Wind Powering America (EERE)

Offshore 90-Meter Wind Maps and Wind Resource Potential Offshore 90-Meter Wind Maps and Wind Resource Potential The Stakeholder Engagement and Outreach initiative provides 90-meter (m) height, high-resolution wind maps and estimates of the total offshore wind potential that would be possible from developing the available offshore areas. The offshore wind resource maps can be used as a guide to identify regions for commercial wind development. A map of the United States showing offshore wind resource. Washington offshore wind map. Oregon offshore wind map. California offshore wind map. Texas offshore wind map. Minnesota offshore wind map. Lousiana offshore wind map. Wisconsin offshore wind map. Michigan offshore wind map. Michigan offshore wind map. Illinois offshore wind map. Indiana offshore wind map. Ohio offshore wind map. Georgia offshore wind map. South Carolina offshore wind map. North Carolina offshore wind map. Virginia offshore wind map. Maryland offshore wind map. Pennsylvania offshore wind map. Delaware offshore wind map. New Jersey offshore wind map. New York offshore wind map. Maine offshore wind map. Massachusetts offshore wind map. Rhode Island offshore wind map. Connecticut offshore wind map. Hawaii offshore wind map. Delaware offshore wind map. New Hampshire offshore wind map.

499

Orifice-meter measurement errors caused by gas-system pulsations can be controlled  

SciTech Connect (OSTI)

Pulsation-induced inaccuracies in orifice meter gas-flow measurement can be eliminated or at least better controlled. In today's increasingly competitive gas-supply marketplace, such errors can no longer be ignored. In some instances, pulsations have caused errors of 30-50% in volumes. Policies and procedures of Arkla Energy Resources, Shreveport, La., reflect current efforts to combat the problem. Orifice-meter pulsation error can be divided into three categories: those associated with the primary element itself (across the flange taps); those in the gauge line/manifold/transducer system;; and those within the recording and analysis system. Each category is significant in that total meter error contains all three types (box). While it would be desirable to segregate the problems and solve them independently, it is very difficult to do. It becomes apparent quickly that all three occur in many cases. The focus of this discussion is on primary-element errors; if these are reduced, other errors tend to be minimal.

Gegg, D. (Arkla Energy Resources, Shreveport, LA (US))

1989-10-16T23:59:59.000Z

500

Small integrating meter for assessing long-term exposure to magnetic fields  

SciTech Connect (OSTI)

A small, lightweight meter has been developed for magnetic-field measurements, particularly those needed for exposure-assessment purposes. This meter, known as the AMEX-3D, continuously measures all three axes of magnetic-flux density and electronically combines the data into a single estimate of cumulative exposure to the root-mean-square (rms) resultant flux density. The AMEX-3D weighs about 120 g, measures 2.7 cm x 5.1 cm x 10.2 cm, and is battery powered. Two panel-mounted jacks are provided for measuring battery voltage and for reading cumulative exposure data from the unit. The instrument has, within 3 dB, a flat response to magnetic flux densities at all frequencies in its 30-1,000 Hz bandwidth. A detailed analysis of error sources in the AMEX-3D leads to an estimate of [plus minus] 20% as the accuracy of the instrument over its dynamic range, which extends from 0.02 to 15 microT. The AMEX-3D was tested in the field by asking electric-utility distribution linemen to wear AMEX-3D and EMDEX meters simultaneously while working. Agreement between the two measures of exposure was excellent.

Kaune, W.T.; Niple, J.C.; Liu, M.J.; Silva, J.M. (Enertech Consultants, Campbell, CA (United States))

1992-01-01T23:59:59.000Z