Powered by Deep Web Technologies
Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Planning of distribution networks for medium voltage and low voltage.  

E-Print Network (OSTI)

??Determination of the placement and rating of transformers and feeders are the main objective of the basic distribution network planning. The bus voltage and the… (more)

Ziari, Iman

2011-01-01T23:59:59.000Z

2

Utility-Scale Solar Power Converter: Agile Direct Grid Connect Medium Voltage 4.7-13.8 kV Power Converter for PV Applications Utilizing Wide Band Gap Devices  

SciTech Connect

Solar ADEPT Project: Satcon is developing a compact, lightweight power conversion device that is capable of taking utility-scale solar power and outputting it directly into the electric utility grid at distribution voltage levels—eliminating the need for large transformers. Transformers “step up” the voltage of the power that is generated by a solar power system so it can be efficiently transported through transmission lines and eventually “stepped down” to usable voltages before it enters homes and businesses. Power companies step up the voltage because less electricity is lost along transmission lines when the voltage is high and current is low. Satcon’s new power conversion devices will eliminate these heavy transformers and connect a utility-scale solar power system directly to the grid. Satcon’s modular devices are designed to ensure reliability—if one device fails it can be bypassed and the system can continue to run.

None

2012-01-25T23:59:59.000Z

3

An amorphous alloy core medium frequency magnetic-link for medium voltage photovoltaic inverters  

Science Journals Connector (OSTI)

The advanced magnetic materials with high saturation flux density and low specific core loss have led to the development of an efficient compact and lightweight multiple-input multiple-output medium frequency magnetic-link. It offers a new route to eliminate some critical limitations of recently proposed medium voltage photovoltaic inverters. In this paper a medium frequency magnetic-link is developed with Metglas amorphous alloy 2605S3A. The common magnetic-link generates isolated and balanced multiple DC supplies for all of the H-bridge inverter cells of the medium voltage inverter. The design and implementation of the prototype test platform and the experimental test results are analyzed and discussed. The medium frequency non-sinusoidal excitation electromagnetic characteristics of alloy 2605S3A are also compared with that of alloy 2605SA1. It is expected that the proposed new technology will have great potential for future renewable power generation systems and smart grid applications.

2014-01-01T23:59:59.000Z

4

Transient recovery voltage considerations in the application of medium voltage circuit breakers  

SciTech Connect

Medium Voltage Circuit Breakers can fail to interrupt 3-phase fault currents when power systems have Transient Recovery Voltage (TRV) characteristics which exceed the rating of the circuit breaker. This paper examines the application of 13.8kV generation and load switchgear for an oil refinery in which circuit parameters as originally designed would have exceeded the 13.8kV circuit breakers TRV ratings had corrective measures not been taken. This paper illustrates this case and discusses the basis of TRV, how TRV is assessed, and alternative actions taken to bring circuits to within the 13.8 kV circuit breaker ratings.

Swindler, D.L.; Schwartz, P.; Hamer, P.S.; Lambert, S.R.

1995-12-31T23:59:59.000Z

5

Electric Field Calculations on Dry-Type Medium Voltage Current Transformers.  

E-Print Network (OSTI)

??This research presents potential and electric field calculations on medium voltage (MV) epoxy insulated outdoor current transformers (CTs) using a numeri-cal calculation approach. Two designs… (more)

Lakshmichand Jain, Sandeep Kumar

2012-01-01T23:59:59.000Z

6

Optimal Placement of the Wind Generators in the Medium Voltage Power Grid  

Science Journals Connector (OSTI)

The minimization of power losses in the medium voltage (MV) grid requires adjustment of network of power sources. This problem is particularly important for renewable energy sources, for example for the farms of wind generators. Their placement and nominal ... Keywords: medium voltage power grid, wind generators, genetic algorithms, parallel processing

Andrzej Jordan; Ryszard Szczebiot; Carsten Maple; Slawomir Cieslik

2011-04-01T23:59:59.000Z

7

Application of evolutionary algorithms for the planning of urban distribution networks of medium voltage  

E-Print Network (OSTI)

Abstract—Currently, an important issue in power distribution is the need to optimize medium voltage (mv) networks serving urban areas. This paper shows how an evolutionary algorithm can be used as the basis for the type of efficient algorithm such optimization demands. The search for optimal network solution will be restricted to a graph defined from the urban map, so each graph branch represents a trench. The solution space (networks) is assumed with “loop feeder circuits”: networks with two electrical paths from the high voltage/medium voltage (hv/mv) substations to the customers. In the optimization process, the investment and loss load costs are considered taking into account the constraints of conductor capacities and voltage drop. The investment costs will take into account that some cables can be lying in the same trench. The process was applied for a Spanish city of 200 000 inhabitants. Index Terms—Evolutionary algorithm, medium voltage network planning, network design, urban distribution network. I.

unknown authors

2002-01-01T23:59:59.000Z

8

Analysis of asset health : an approach to monitoring and diagnostics for medium voltage circuit breakers  

E-Print Network (OSTI)

The Medium Voltage Electric Industry is a very conservative and risk adverse sector that has undergone very little change in the past 30 years when compared to other technologically dependent activities; this reality is ...

Corona, Erick (Erick Gustavo)

2013-01-01T23:59:59.000Z

9

Towards Decentralized Trading: A Topological Investigation of the Dutch Medium and Low Voltage Grids  

E-Print Network (OSTI)

The traditional Power Grid has been designed in a hierarchical fashion, with Energy pushed from the large scale production facilities towards the end users. But with the increasing availability of micro and medium scale generating facilities, the situation is changing. Many end users can now produce energy and share it over the Power Grid. Naturally, end users need to have incentives to do so and might want to be able to act in an open decentralized energy market. In the present work, we offer a novel analysis of the Medium and Low Voltage Power Grids of the North Netherlands using statistical tools from the Complex Network Analysis field. We use a weighted model based on actual Grid data and propose a set of statistical measures to evaluate the adequacy of the current infrastructure for a decentralized energy market. Further, we use the insight gained by the analysis to propose parameters that tie the statistical topological measures to economic factors that might influence the attractiveness to the end user...

Pagani, Giuliano Andrea

2011-01-01T23:59:59.000Z

10

Comparative study of voltage oriented and frequency coordinated control of grid connected doubly fed induction generator  

Science Journals Connector (OSTI)

In this paper a comparative study between voltage oriented control (VOC) and frequency coordinated control (FCC) of grid connected doubly fed induction generator (DFIG) is presented. The two method controls are deeply done on DFIG converter sides grid side converter (GSC) and rotor side converter (RSC). The VOC method permanently maintains the DFIG reactive power to zero values to achieve stable voltage. This control is implemented by regulating the rotor direct axis reference current in RSC using grid reactive power. On the other hand the FCC has employed the active power obtaining from the system frequency deviation to control the rotor quadrature axis reference current in the RSC. The GSC is the same in two studies and its applied vector controlled method. The comparison study between the two methods is conducted at a steady and dynamic state under constant and variable wind speeds. The simulation results are carried out by using PSCAD/EMTDC electromagnetic transient program to validate the comparison study between two methods control of DFIG. The outcomes of the simulation show that the VOC is very convenient when the DFIG operated at transient mode and variable wind speeds while the FCC is feasible and effective for steady-state mode applications. Furthermore the FCC method has an ability to reduce the active and reactive powers ripples as well as decreasing torque harmonics. Both of two methods had fewer transient recovery values of output parameters which ensure safety dynamic response of DFIG and power system. This study contributes significantly to choose the suitable control of the DFIG converters according to electrical grid operation conditions. In addition if a joint control has been applied to these two methods the wind power gained strong and flexible control of the frequency and voltage for different operating conditions.

Li Yang

2014-01-01T23:59:59.000Z

11

Connecting Renewables Directly to the Grid: Resilient Multi-Terminal HVDC Networks with High-Voltage High-Frequency Electronics  

SciTech Connect

GENI Project: GE is developing electricity transmission hardware that could connect distributed renewable energy sources, like wind farms, directly to the grid—eliminating the need to feed the energy generated through intermediate power conversion stations before they enter the grid. GE is using the advanced semiconductor material silicon carbide (SiC) to conduct electricity through its transmission hardware because SiC can operate at higher voltage levels than semiconductors made out of other materials. This high-voltage capability is important because electricity must be converted to high-voltage levels before it can be sent along the grid’s network of transmission lines. Power companies do this because less electricity is lost along the lines when the voltage is high.

None

2012-01-23T23:59:59.000Z

12

Backstepping DC Voltage Control in a Multi-terminal HVDC System Connecting Offshore Wind Farms  

Science Journals Connector (OSTI)

Wind power is projected to play an important ... current and future power systems. To integrate offshore wind farms to the existing onshore grid, voltage source ... in a safe range. To distribute transmitted wind

Xiaodong Zhao; Kang Li; Yusheng Xue

2014-01-01T23:59:59.000Z

13

Voltage and Frequency Control in Offshore Wind Turbines Connected to Isolated Oil Platform Power Systems  

Science Journals Connector (OSTI)

Offshore wind turbines have potential to supply offshore oil and gas platforms in the North Sea with electric energy. For remote located facilities it is attractive to pursue a solution where the wind turbines and oil platform operate in an isolated system. To study the operational properties of a system with these characteristics is necessary to identify possible advantages and disadvantages. This paper demonstrates how added voltage and frequency control in wind turbines equipped with full power electronic converters can improve the voltage and frequency stability in offshore oil and gas installations. The work is based on an electrical simulation model built in the PSCAD software. In the proposed transient simulation scenarios, the voltage dip is reduced from 16% to 6%, while the frequency overshoot is reduced from 97% to 25%. These are significant improvements that should be taken into consideration when offshore wind power is evaluated as power supply to oil installations.

Atle Rygg Ĺrdal; Tore Undeland; Kamran Sharifabadi

2012-01-01T23:59:59.000Z

14

Automatic voltage imbalance detector  

DOE Patents (OSTI)

A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

1984-01-01T23:59:59.000Z

15

A design for the interface between a battery storage and charging unit, and a medium voltage DC (MVDC) bus, as part of an integrated propulsion system (IPS) in the all electric ship (AES)  

Science Journals Connector (OSTI)

In this paper we present the design of a rechargeable battery storage device for use in an all-electric ship. The purpose of this device is to provide power of predictable quality to selected equipment. In addition a recharging unit is proposed for recharging ... Keywords: electric ship, energy storage, medium voltage DC (MVDC), pulse load

T. A. Trapp; P. Prempraneerach; C. Chryssostomidis; J. L. Kirtley, Jr.; G. E. Karniadakis

2011-06-01T23:59:59.000Z

16

2.3-MW Medium-Voltage, Three-Level Wind Energy Inverter Applying a Unique Bus Structure and 4.5-kV Si/SiC Hybrid Isolated Power Modules: Preprint  

SciTech Connect

A high-efficiency, 2.3-MW, medium-voltage, three-level inverter utilizing 4.5-kV Si/SiC (silicon carbide) hybrid modules for wind energy applications is discussed. The inverter addresses recent trends in siting the inverter within the base of multimegawatt turbine towers. A simplified split, three-layer laminated bus structure that maintains low parasitic inductances is introduced along with a low-voltage, high-current test method for determining these inductances. Feed-thru bushings, edge fill methods, and other design features of the laminated bus structure provide voltage isolation that is consistent with the 10.4-kV module isolation levels. Inverter efficiency improvement is a result of the (essential) elimination of the reverse recovery charge present in 4.5-kV Si PIN diodes, which can produce a significant reduction in diode turn-off losses as well as insulated-gate bipolar transistor (IGBT) turn-on losses. The hybrid modules are supplied in industry-standard 140 mm x 130 mm and 190 mm x 130 mm packages to demonstrate direct module substitution into existing inverter designs. A focus on laminated bus/capacitor-bank/module subassembly level switching performance is presented.

Erdman, W.; Keller, J.; Grider, D.; VanBrunt, E.

2014-11-01T23:59:59.000Z

17

Voltage balanced multilevel voltage source converter system  

DOE Patents (OSTI)

A voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

18

Voltage balanced multilevel voltage source converter system  

DOE Patents (OSTI)

Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-07-01T23:59:59.000Z

19

Charge-pump voltage converter  

DOE Patents (OSTI)

A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

Brainard, John P. (Albuquerque, NM); Christenson, Todd R. (Albuquerque, NM)

2009-11-03T23:59:59.000Z

20

ABBGroup-1-High voltage lab  

E-Print Network (OSTI)

;©ABBGroup-3- 3-Sep-07 Where does one use circuit breakers? High voltage (HV) circuit breakers are keyA DISTRIBUTION MEDIUM AND LOW VOLTAGE HV circuit breakers #12;©ABBGroup-4- 3-Sep-07 When a breaker fails to interrupt the current... Fault arc at a disconnector Fault arc in a substation #12;©ABBGroup-5- 3-Sep-07

Basse, Nils Plesner

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Definition: Automated Voltage Regulators | Open Energy Information  

Open Energy Info (EERE)

Regulators Regulators Jump to: navigation, search Dictionary.png Automated Voltage Regulators Voltage regulators are transformers that can increase or decrease the voltage on a distribution circuit to help keep the voltage within a pre-determined band. Unlike capacitor banks, voltage regulators cannot adjust power factor. These devices typically monitor the voltage at the location where they are connected, and compare it to a programmed set point. If the voltage deviates too far from the set point, the voltage regulator can increase or decrease its output voltage by moving the tap on the secondary side up or down. An automated voltage regulator can operate with remote control signals, or in concert with other area voltage control devices, to help regulate distribution voltage in a coordinated fashion.

22

High-voltage engineering  

E-Print Network (OSTI)

High-voltage engineering covers the application, the useful use and proper working of high voltages and high fields. Here we give some introductory examples, i.e., ‘septa’ and ‘kicker’ at the Large Hadron Collider (14 TeV), the Super Proton Synchrotron (450 GeV) and the Proton Synchrotron (26 GeV) accelerators as found at the European Orginization for Nuclear Research (CERN) today. We briefly cover the theoretical foundation (Maxwell equations) and aspects of numerical field simulation methods. Concepts relating to electrical fields, insulation geometry and medium and breakdown are introduced. We discuss ways of generating high voltages with examples of AC sources (50/60 Hz), DC sources, and pulse sources. Insulation and breakdown in gases, liquids, solids and vacuum are presented, including Paschen’s law (breakdown field and streamer breakdown). Applications of the above are discussed, in particular the general application of a transformer. We briefly discuss measurement techniques of partial disch...

Gaxiola, E

2006-01-01T23:59:59.000Z

23

Centralized wind power plant voltage control with optimal power flow algorithm.  

E-Print Network (OSTI)

??This thesis presents a method of controlling the reactive power injected into a medium-voltage collection system by multiple wind turbine generators such that the voltage… (more)

Kline, Jared Andrew

2011-01-01T23:59:59.000Z

24

Voltage controlled current source  

DOE Patents (OSTI)

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, Gregory M. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

25

Ignition distributor voltage generator  

SciTech Connect

This patent describes a voltage pulse generator and ignition distributor comprising, a base, a shaft rotatably supported by the base, a distributor cap supported by the base having a center electrode and circumferentially spaced outer electrodes. The pulse generator and ignition distribution also include a first rotor driven by the shaft formed of electrical insulating material having electrically conductive means connected to the center terminal and a portion that rotates past the outer electrodes. The portion of the electrically conductive means that rotates past the outer electrodes is spaced from the outer electrodes to form a gap therebetween. A voltage pulse generator comprises a second rotor driven by the shaft, at least one permanent magnet and an annular pickup coil supported by the base. The pickup coil has inner turns and outer turns, the beginning turn of the inner turns connected to a first lead and the last turn of the outer turns connected to a second lead, the outer turns enclosing the inner turns. The pickup coil also has a circuit connected directly between the second lead and ground which is operative to provide a direct conductive path to ground for high frequency energy capacitively coupled to the outer turns from the gap discharge between the electrically conductive means of the first rotor and an outer electrode, the outer turns forming a grounded shield for the inner turns.

Boyer, J.A.

1986-11-04T23:59:59.000Z

26

ABBGroup-1-High voltage lab  

E-Print Network (OSTI)

A DISTRIBUTION MEDIUM AND LOW VOLTAGE HV circuit breakers #12;©ABBGroup-4- 3-Sep-07 When a breaker fails to interrupt the current... Fault arc at a disconnector Fault arc in a substation #12;©ABBGroup-5- 3-Sep-07/costs A detailed understanding of arc physics and fluid dynamics is necessary for the development of HV circuit

Basse, Nils Plesner

27

Research to Prevent the Anti-charging Incident of the Voltage Transformer in the Substation  

Science Journals Connector (OSTI)

The voltage transformer of the power system is a device which converts the high voltage of the primary side into the low voltage required by secondary device, and the primary side connects to the primary syste...

Hui-Ying Chen; Zhi-Peng Wang; Mu-Qin Tian

2011-01-01T23:59:59.000Z

28

Fig. 1. Circuit diagram of LCC resonant inverter, HV-transformer and symmetrical three-stage voltage multiplier rectifier [9] (Each of the shown diode consists of 10 single diodes connected in series with parallel snubbers and capacitors).  

E-Print Network (OSTI)

Böcker Paderborn University Power Electronics and Electrical Drives 33095 Paderborn, Germany E-Mail: {hu the circuit diagram of the power supply generating the positive half-wave of the test voltage: The zero, industrial control, modeling, reduced-order systems. I. INTRODUCTION Mobile (HV) high voltage test generators

Paderborn, Universität

29

Distributed voltage control strategy for LV networks with inverter-interfaced generators  

Science Journals Connector (OSTI)

Abstract Low voltage distribution networks are characterized by an ever growing diffusion of single and three phase distributed generators whose unregulated operation may deplete the power quality levels, in particular as regard voltage profiles and unbalances. This issue is at present under discussion by several national and international standardization bodies and the general trend is to require, for the new connections of generators to medium and low voltage grids, their participation to the reactive power network management. In this paper a novel strategy proposes to control the network voltage unbalance suitably for coordinating single and three-phase inverter interfaced embedded generators, concurrently with a local volt/var regulation action as foreseen by the new grid connection requirements. Simulations conducted on case study network representing a typical Italian 4-wire LV distribution system under different load/generation conditions, demonstrate that the coordinated action of single-phase and three-phase inverters may considerably reduce the degree of unbalance thus improving the network power quality levels.

R. Caldon; M. Coppo; R. Turri

2014-01-01T23:59:59.000Z

30

Graz University of Technology Institute of High Voltage Engineering and System Performance  

E-Print Network (OSTI)

.hspt@tugraz.at u www.hspt.tugraz.at Institute of High Voltage Engineering and System Performance Test Laboratory systems Test of insulators, fittings and accessories Testing of high voltage equipment Impulse voltage and current tests On-site-test of medium voltage cables Electrical methods in environmental technology

31

Capacitively coupled RF voltage probe having optimized flux linkage  

DOE Patents (OSTI)

An RF sensor having a novel current sensing probe and a voltage sensing probe to measure voltage and current. The current sensor is disposed in a transmission line to link all of the flux generated by the flowing current in order to obtain an accurate measurement. The voltage sensor is a flat plate which operates as a capacitive plate to sense voltage on a center conductor of the transmission line, in which the measured voltage is obtained across a resistance leg of a R-C differentiator circuit formed by the characteristic impedance of a connecting transmission line and a capacitance of the plate, which is positioned proximal to the center conductor.

Moore, James A. (Powell, TN); Sparks, Dennis O. (Maryville, TN)

1999-02-02T23:59:59.000Z

32

High voltage load resistor array  

DOE Patents (OSTI)

A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

Lehmann, Monty Ray (Smithfield, VA)

2005-01-18T23:59:59.000Z

33

Eliminate Excessive In-Plant Distribution System Voltage Drops...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

connections-can account for less than 1% to more than 4% of total plant electrical energy consumption. This two-page tip sheet recommends conducting a voltage drop survey and...

34

Method of Controlling Corona Effects and Breakdown Voltage of Small Air Gaps Stressed by Impulse Voltages  

E-Print Network (OSTI)

This paper investigates the influence of a resistor on the dielectric behavior of an air gap. The resistor is connected in series with the air gap and the latter is stressed by impulse voltage. Air gap arrangements of different geometry with either the rod or the plate grounded are stressed with impulse voltages of both positive and negative polarity. The resistor is connected in series with the air gap in the return circuit connecting the gap with the impulse generator. The method followed involves the investigation of the graphs of the charging time concerning the air gaps capacitances, in connection to the value of the resistor, the geometry of the gap, the effect of grounding and the polarity effect. It is determined that the charging time of the air gap increases, as the value of the resistor increases. It is also determined that the peak voltage value of the fully charged air gap decreases as the value of the resistor increases. The results of the mathematical and simulation analysis are compared with the results of the oscillograms taken from experimental work. In addition and consequently to the above results it is concluded from the experimental work that the in series connection of the resistor in the circuit has significant influence on corona pulses (partial discharges) occurring in the gap and on the breakdown voltage of the gap. A new method of controlling the corona effects and consequently the breakdown voltage of small air gaps stressed by impulse voltage of short duration in connection to the ground effect and the polarity effect has arisen. Furthermore through mathematical analysis of the charging graphs obtained from simulation and experimental oscillograms there was a calculation of the values of the capacitance of the air gaps in relation to their geometry and the results were compared to the values calculated with mathematical analysis.

Athanasios Maglaras; Trifon Kousiouris; Frangiskos Topalis; Dimitrios Katsaros; Leandros A. Maglaras; Konstantina Giannakopoulou

2014-10-15T23:59:59.000Z

35

Peering Connections  

NLE Websites -- All DOE Office Websites (Extended Search)

Publications and Presentations Galleries ESnet Awards and Honors ESnet Live Blog Home Engineering Services The Network Peering Connections Engineering Services The...

36

Network Connections  

NLE Websites -- All DOE Office Websites (Extended Search)

Connecting to NERSC Using X Windows Connecting to NERSC with NX Transferring Data Network Performance Queues and Scheduling Job Logs & Analytics Training & Tutorials Software Accounts & Allocations Policies Data Analytics & Visualization Data Management Policies Science Gateways User Surveys NERSC Users Group User Announcements Help Operations for: Passwords & Off-Hours Status 1-800-66-NERSC, option 1 or 510-486-6821 Account Support https://nim.nersc.gov accounts@nersc.gov 1-800-66-NERSC, option 2 or 510-486-8612 Consulting http://help.nersc.gov consult@nersc.gov 1-800-66-NERSC, option 3 or 510-486-8611 Home » For Users » Network Connections Network Connections NERSC's resources can be accessed using SSH and related tools, grid tools, and via the web. This section explains how to connect to NERSC

37

AN "AC INDUCTOR" BASED GRID CONNECTED INVERTER  

E-Print Network (OSTI)

AN "AC INDUCTOR" BASED GRID CONNECTED INVERTER Ilya Zeltser, Student Member, IEEE and Sam Ben proposes a soft switched Output Current Sourcing (OCS) grid connected inverter that applies a high sourcing inverters where the small disturbance at the line voltage may lead to current run away

38

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

39

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power Filter Applications  

E-Print Network (OSTI)

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power voltage-source inverters connected in series (known as cascaded hybrid asymmetric multilevel inverter voltage application due to semiconductor constraint. In order to achieve higher power level, hybrid

Catholic University of Chile (Universidad CatĂłlica de Chile)

40

Constant voltage ultracapacitor  

Science Journals Connector (OSTI)

Ultracapacitors have attracted lots of attention recently due to their growing use in hybrid vehicles and in energy storage applications for the smart grid. A very undesirable feature of ultracapacitors is the fact that the voltage drops as the capacitor is discharged. DC-DC converters are employed at present to convert the voltage of the ultracapacitor to constant voltage; however these converters typically do not operate if the voltage of the ultracapacitor drops below 1?V. In addition DC-DC converters suffer from well-known size/efficiency tradeoffs. This paper introduces a novel new ultracapacitor that is characterized by constant voltage. The new ultracapacitor does not utilize familiar energy conversion principles. Rather operation depends on an embedded electromechanical system that actually alters the capacitance of the ultracapacitor as the device is discharged. Due to a simple proportionality relationship between charge capacitance and voltage the voltage remains constant. Theoretical and experimental investigations have shown that the embedded mechanism for altering the capacitance has an efficiency of 99% or higher.

Ezzat G. Bakhoum

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Substation voltage upgrading  

SciTech Connect

Substation voltage uprating, i.e., conversion of a substation from a lower rated voltage to a higher rated voltage without a complete substation rebuild, can lead to excellent economic benefits. Utilization of the old substation layout and/or the existing equipment, to some extent, is the practical objective of such an uprating. The objective of this project was to assess the opportunities for substation uprating in the industry, to establish feasibility for such uprating and to study methods for accomplishing it. The final aim of the project was to provide guidance to utilities interested in uprating. 56 refs., 41 figs., 18 tabs.

Panek, J.; Elahi, H.; Sublich, M. (General Electric Co., Schenectady, NY (USA). Systems Development and Engineering Dept.)

1989-08-01T23:59:59.000Z

42

High voltage DC power supply  

DOE Patents (OSTI)

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

Droege, T.F.

1989-12-19T23:59:59.000Z

43

High voltage DC power supply  

DOE Patents (OSTI)

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

Droege, Thomas F. (Batavia, IL)

1989-01-01T23:59:59.000Z

44

Low-voltage gyrotrons  

SciTech Connect

For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5-10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%-2% in the submillimeter wavelength region).

Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S. [Institute of Applied Physics RAS, N. Novgorod 603600 (Russian Federation); Nusinovich, G. S. [IREAP, University of Maryland, College Park, Maryland 20742-3511 (United States)

2013-03-15T23:59:59.000Z

45

Offshore Wind Park Connection to an HVDC Platform, without using an AC Collector Platform.  

E-Print Network (OSTI)

?? This thesis investigates the comparison between two different alternating current topologies of an offshore wind farms connection to an offshore high voltage direct current… (more)

Ahmad, Haseeb

2012-01-01T23:59:59.000Z

46

High voltage electrical amplifier having a short rise time  

DOE Patents (OSTI)

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

1991-01-01T23:59:59.000Z

47

Optically triggered high voltage switch network and method for switching a high voltage  

DOE Patents (OSTI)

An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

1993-01-19T23:59:59.000Z

48

High voltage pulse conditioning  

DOE Patents (OSTI)

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

1990-01-01T23:59:59.000Z

49

Design of a Robust Digital Current Controller for a Grid Connected Interleaved Inverter  

E-Print Network (OSTI)

Design of a Robust Digital Current Controller for a Grid Connected Interleaved Inverter M. A for a three- phase voltage source grid-connected interleaved inverter. Each phase consists of 6 half small output filter capacitors are required which provide high impedance to grid voltage harmonics

50

Voltage controlled stand-alone microhydro induction generator system  

Science Journals Connector (OSTI)

The paper discusses simulated control cases of the wound rotor self-excited induction generator WRSEIG. The generator external controller is designed to regulate the output voltage and frequency for constant or variable speed operation of the prime mover and has the inherent capability of protecting the load from short circuit, which permits voltage collapse under heavy loads. WRSEIG is self-excited using one set of excitation capacitance connected across the generator stator side. At the rotor side, a PWM controlled resistor is connected to the rotor windings through the rotating slips and act as a slip power controller. The controller can be configured to regulate the voltage as the speed or the load changes. The presented system has the capability to generate good quality AC power source with minimum controlling elements and can operate under constant or adjustable prime mover speed that suits many microhydro electricity-generating plants.

K.A. Nigim

2005-01-01T23:59:59.000Z

51

Nonlinear DSTATCOM controller design for distribution network with distributed generation to enhance voltage stability  

E-Print Network (OSTI)

Nonlinear DSTATCOM controller design for distribution network with distributed generation Accepted 19 June 2013 Keywords: Distributed generation Distribution network DSATACOM Partial feedback connected to a distribution network with distributed generation (DG) to regulate the line voltage

Pota, Himanshu Roy

52

A genetic algorithm approach to voltage-VAR control in systems with distributed generation  

Science Journals Connector (OSTI)

This paper presents a case study that highlights the influences which the connection of distributed generation sources may have over the solutions of reactive power compensation and voltage control already existing in a given network. The problem of ... Keywords: distributed generation, genetic algorithms, renewable sources, voltage-var control

Iulia Coroama; Mihai Gavrilas; Ovidiu Ivanov

2010-10-01T23:59:59.000Z

53

VOLTAGE COLLAPSE AND TRANSIENT ENERGY FUNCTION ANALYSES OF AC/DC SYSTEMS  

E-Print Network (OSTI)

for power system dynamic models, including a third order representation of high voltage direct current (HVDC power limits, HVDC firing angle limits and voltage dependent current order limits (VDCOL) are shown the derivation of individual component Lyapunov functions for simplified models of HVDC links connected

Cañizares, Claudio A.

54

Multilevel-Dc-Bus Inverter For Providing Sinusoidal And Pwm Electrical Machine Voltages  

DOE Patents (OSTI)

A circuit for controlling an ac machine comprises a full bridge network of commutation switches which are connected to supply current for a corresponding voltage phase to the stator windings, a plurality of diodes, each in parallel connection to a respective one of the commutation switches, a plurality of dc source connections providing a multi-level dc bus for the full bridge network of commutation switches to produce sinusoidal voltages or PWM signals, and a controller connected for control of said dc source connections and said full bridge network of commutation switches to output substantially sinusoidal voltages to the stator windings. With the invention, the number of semiconductor switches is reduced to m+3 for a multi-level dc bus having m levels. A method of machine control is also disclosed.

Su, Gui-Jia [Knoxville, TN

2005-11-29T23:59:59.000Z

55

Substation voltage upgrading  

SciTech Connect

This report addresses specific issues to support sound yet not unduly conservative uprating practices for substations. The main parts of the report cover the insulation withstand and overvoltage protection aspects, environmental measurements, reliability criteria, and industry experience. First the insulation design concerns are addressed. Substation stress by a backflashover of the line insulation due to lightning in the vicinity of the substation is recognized as a critical stress. A representative part of a 550 kV BIL substation was erected at the EPRI High Voltage Transmission Research Center, where also a special test circuit was assembled to produce a fast front, slow tail (0.2/200 {mu}s) wave. The substation as well as some special configurations were tested for line-to-ground and line-to-line withstand. Computer studies were performed to complement the test results. A number of important conclusions was reached. The most prominent result in that the high frequency oscillations, as caused by reflections within the substation, do not effect the Critical Flashover Voltage (CFO). The present practice, based on the highest peak is therefore very conservative. The slow tail of the wave appears to dictate the CFO. An arrester model for computer studies to represent very fast as well as slow phenomena was derived. It is based on full scale arrester test data, made available in this project. The computer program to calculate arrester model parameters is also a part of the report. The electric environmental measurements are reported for the tested substation at the HVTRC and for the uprated substation of Public Service Company of Colorado, both before and after the uprating. The performance is satisfactory when corona free hardware is used. Insulation design criteria are analyzed based on substation reliability, the system viewpoint and consequences of the failure. Utility experience with uprated substations is reviewed.

Panek, J.; Elahi, H.; Lux, A.; Imece, A.F. (General Electric Co., Schenectady, NY (United States). Power Systems Engineering Dept.); LaPanse, R.A.; Stewart, J.R. (Public Service Co. of Colorado, Denver, CO (United States))

1992-04-01T23:59:59.000Z

56

ConnectingXfering.pdf  

NLE Websites -- All DOE Office Websites (Extended Search)

* Data - Potential performance penalty usually not a problem - Can forward TCP ports and X11 connections - Protocol version 2 since 2006 Connecting with SSH * Server -...

57

Reduction of interference on substation low voltage wiring  

SciTech Connect

This paper describes test results and mitigation methods of electromagnetic interference (EMI) on control and low voltage circuits in substations caused by air disconnect switch operation. The tests are focused on a comparison between unshielded and shielded circuits from capacitively coupled voltage transformers (CCVT) and other equipment circuits in the vicinity. New test data are presented comparing unshielded and shielded cables and transient currents on all connections to the CCVT including the pedestal and ground strap. The paper gives a practical and understandable explanation of the causes of EMI in substations and how shielded cable and parallel ground conductors reduce interference. Design guidelines are listed in the Conclusion.

Gavazza, R.J. [Pacific Gas and Electric Co., San Francisco, CA (United States)] [Pacific Gas and Electric Co., San Francisco, CA (United States); Wiggins, C.M. [Carl M. Wiggins and Associates, Friendswood, TX (United States)] [Carl M. Wiggins and Associates, Friendswood, TX (United States)

1996-07-01T23:59:59.000Z

58

Temperature controlled high voltage regulator  

DOE Patents (OSTI)

A temperature controlled high voltage regulator for automatically adjusting the high voltage applied to a radiation detector is described. The regulator is a solid state device that is independent of the attached radiation detector, enabling the regulator to be used by various models of radiation detectors, such as gas flow proportional radiation detectors.

Chiaro, Jr., Peter J. (Clinton, TN); Schulze, Gerald K. (Knoxville, TN)

2004-04-20T23:59:59.000Z

59

Experiment Hazard Class 13.0 - High Voltage  

NLE Websites -- All DOE Office Websites (Extended Search)

3.0 - High Voltage 3.0 - High Voltage Applicability This hazard classification applies to all experiments involving the use of High Voltage Equipment. Other hazard classifications and their associated hazard controls may also apply to experiments in this hazard class. The inspection of electric equipment is covered under the APS Policy For User Electric Equipment Inspections. NOTE: Unless required Argonne training has been completed, users are not authorized to perform electrical work. Experiment Category All Hazard Class 13 experiments are categorized as medium risk experiments. Experiment Hazard Control Verification Statements Engineered Controls - Determined by review and results of a DEEI inspection of the equipment. Procedural Controls - Determined by review and results of a DEEI

60

APPA Customer Connections Conference  

Office of Energy Efficiency and Renewable Energy (EERE)

The Customer Connections Conference is APPA's annual meeting for utility professionals in the areas of:

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Charmonium in Hot Medium  

E-Print Network (OSTI)

. The momentum dependence of the charmonium dissociation rate is worked out. The dominant process for in-medium charmonium regeneration is found to be a 3-to-2 process. Its corresponding regeneration rates from different input charmquark momentum spectra...

Zhao, Xingbo

2012-02-14T23:59:59.000Z

62

Amorphous Medium Language  

E-Print Network (OSTI)

Programming reliable behavior on a large mesh network composed of unreliable parts is difficult. Amorphous Medium Language addresses this problem by abstracting robustness and networking issues away from the programmer via ...

Beal, Jacob

63

Low voltage nonprimary explosive detonator  

DOE Patents (OSTI)

A low voltage, electrically actuated, nonprimary explosive detonator is disclosed wherein said detonation is achieved by means of an explosive train in which a deflagration-to-detonation transition is made to occur. The explosive train is confined within a cylindrical body and positioned adjacent to low voltage ignition means have electrical leads extending outwardly from the cylindrical confining body. Application of a low voltage current to the electrical leads ignites a self-sustained deflagration in a donor portion of the explosive train which then is made to undergo a transition to detonation further down the train.

Dinegar, Robert H. (Los Alamos, NM); Kirkham, John (Newbury, GB2)

1982-01-01T23:59:59.000Z

64

Saving Megawatts with Voltage Optimization  

E-Print Network (OSTI)

that had been installed at several electric utility distribution substations in the U.S. and Canada. These systems, being operated in Conservation Voltage Regulation mode, have provided significant energy conservation where they have been installed...

Wilson, T.; Bell, D.

2010-01-01T23:59:59.000Z

65

Design, implementation, and verification of a multipurpose, flexible, three-phase back-to-back voltage-source inverter  

E-Print Network (OSTI)

In this thesis, I designed, implemented, and verified a multi-purpose,three-phase back-to- back voltage source inverter for grid connected applications. This inverter features extensive hardware protection, opto-isolation ...

Chai, Elaina T

2014-01-01T23:59:59.000Z

66

Direct power control of grid connected PV systems with three level NPC inverter  

SciTech Connect

This paper presents the control of a three-level Neutral Point Clamped (NPC) voltage source inverter for grid connected photovoltaic (PV) systems. The control method used is the Extended Direct Power Control (EDPC), which is a generic approach for Direct Power Control (DPC) of multilevel inverters based on geometrical considerations. Maximum Power Point Tracking (MPPT) algorithms, that allow maximal power conversion into the grid, have been included. These methods are capable of extracting maximum power from each of the independent PV arrays connected to each DC link voltage level. The first one is a conventional MPPT which outputs DC link voltage references to EDPC. The second one is based on DPC concept. This new MPPT outputs power increment references to EDPC, thus avoiding the use of a DC link voltage regulator. The whole control system has been tested on a three-level NPC voltage source inverter connected to the grid and results confirm the validity of the method. (author)

Alonso-Martinez, Jaime; Eloy-Garcia, Joaquin; Arnaltes, Santiago [Dept. of Electrical Engineering, University Carlos III of Madrid, Avda. Universidad 30, 28911 Leganes, Madrid (Spain)

2010-07-15T23:59:59.000Z

67

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

Shimer, D.W.; Lange, A.C.

1997-03-11T23:59:59.000Z

68

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1997-01-01T23:59:59.000Z

69

Improving the low voltage ride through of doubly fed induction generator during intermittent voltage source converter faults  

Science Journals Connector (OSTI)

The impact of different voltage source converter (VSC) faults on the low voltage ride through (LVRT) capability of the doubly fed induction generator (DFIG) is also investigated. Faults such as fire-through of the VSC switches and short circuit across the DC-link capacitor are considered in this paper. The impact of internal VSC faults when they occur within the grid side converter (GSC) and rotor side converter is investigated. A proper static synchronous compensator (STATCOM) controller to mitigate the effects of these faults is proposed. The DFIG compliance with numerous and recently released LVRT grid codes under these faults with and without the STATCOM is examined and compared. Simulation results indicate that these types of faults have a severe impact on the DFIG voltage profile especially when these faults occur in the GSC. This is attributed to the fact that the GSC directly regulates the point of common coupling (PCC) voltage. Moreover the proposed controller is capable of bringing the voltage profile at the PCC to the nominal steady state level and hence maintaining the connection of the wind turbine during the various studied faults.

H. R. Pota

2013-01-01T23:59:59.000Z

70

HVDC Connected Offshore Wind Power Plants: Review and Outlook of Current Research  

E-Print Network (OSTI)

HVDC Connected Offshore Wind Power Plants: Review and Outlook of Current Research Jakob Glasdam-of-the-art review on grid integration of large offshore wind power plants (OWPPs) using high voltage direct voltage is to acquire in- depth knowledge of relevant operating phenomena in the offshore OWPP grid, rich with power

Bak, Claus Leth

71

Power Smoothing Control in a Grid-Connected Marine Current Turbine System for Compensating  

E-Print Network (OSTI)

Power Smoothing Control in a Grid-Connected Marine Current Turbine System for Compensating Swell d-axis and q-axis inductances g, g Grid inductance and resistance Pole pair number R Turbine blade-axis and q-axis voltages Turbine and generator power difference , g Rotor position, grid voltage angle

Boyer, Edmond

72

Voltage, energy and power in electric circuits  

E-Print Network (OSTI)

Voltage, energy and power in electric circuits Science teaching unit #12;Disclaimer The Department-2008DVD-EN Voltage, energy and power in electric circuits #12;#12;© Crown copyright 2008 1The National Strategies | Secondary Voltage, energy and power in electric circuits 00094-2008DVD-EN Contents Voltage

Berzins, M.

73

Ancillary service details: Voltage control  

SciTech Connect

Voltage control is accomplished by managing reactive power on an alternating-current power system. Reactive power can be produced and absorbed by both generation and transmission equipment. Reactive-power devices differ substantially in the magnitude and speed of response and in their capital costs. System operators, transmission owners, generators, customers, power marketers, and government regulators need to pay close attention to voltage control as they restructure the U.S. electricity industry. Voltage control can affect reliability and commerce in three ways: (1) Voltages must be maintained within an acceptable range for both customer and power-system equipment to function properly. (2) The movement of reactive power consumes transmission resources, which limits the ability to move real power and worsens congestion. (3) The movement of reactive power results in real-power losses. When generators are required to supply excessive amounts of reactive power, their real-power production must be curtailed. These opportunity costs are not currently compensated for in most regions. Current tariffs are based on embedded costs. These embedded-cost tariffs average about $0.51/MWh, equivalent to $1.5 billion annually for the United States as a whole. Although this cost is low when compared with the cost of energy, it still aggregates to a significant amount of money. This report takes a basic look at why the power system requires reactive power (an appendix explains the fundamentals of real and reactive power). The report then examines the various types of generation and transmission resources used to supply reactive power and to control voltage. Finally it discusses how these resources are deployed and paid for in several reliability regions around the country. As the U.S. electricity industry is restructured, the generation, transmission, and system-control equipment and functions that maintain voltages within the appropriate ranges are being deintegrated.

Kirby, B.; Hirst, E.

1997-12-01T23:59:59.000Z

74

High-Voltage Test Laboratories  

Science Journals Connector (OSTI)

The power for a complete HV laboratory is usually supplied from a medium-...9.20...). One or several three-phase distribution transformers in a nearby substation should be used for that purpose. Their...Sect. 9.2...

Wolfgang Hauschild; Eberhard Lemke

2014-01-01T23:59:59.000Z

75

Monitoring voltage collapse margin with synchrophasors across transmission corridors with multiple lines and multiple contingencies  

E-Print Network (OSTI)

We use synchrophasor measurements of the complex voltage and current at both ends of multiple transmission lines that connect areas of a power system to monitor the online voltage collapse margin. A new reduction is used to reduce the multiple transmission lines to a single line equivalent and determine how to combine the synchrophasor measurements. Generator reactive power limits can be accommodated. The results show that this methodology can capture the effect of multiple contingencies inside the transmission corridors, giving awareness to the operators about the severity of contingencies with respect to voltage stability.

Ramirez, Lina

2014-01-01T23:59:59.000Z

76

Current vs. Voltage Feedback Amplifiers  

E-Print Network (OSTI)

?' In most applications, the differences between current feedback (CFB) and voltage feedback (VFB) are not apparent. Today's CFB and VFB amplifiers have comparable performance, but there are cer- tain unique Performance · Feedback Freedom Aside from the well-known attribute of CFB amplifiers, gain

Lanterman, Aaron

77

Modulated voltage metastable ionization detector  

SciTech Connect

Metastable ionization detectors used for chromatographic analysis usually employa fixed high voltage for the ionization potential. For this reason, the operating range is limited to about three orders of magnitude. By use of the technique disclosed in the instant invention, operating ranges of about nine orders of magnitude are obtained. The output current from a metastable ionization detector (MID) is applied to a modulation voltage circuit. An adjustment is made to balance out the background current, and an output current, above background, is applied to an input of a strip chart recorder. For low level concentrations, i.e., low detected output current, the ionization potential will be at a maximum and the metastable ionization detector will operate at its most sensitive level. When the detected current from the metastable ionization detector increases above a predetermined threshold level, a voltage control circuit is activated which turns on a high voltage transistor which acts to reduce the ionization potential. The ionization potential applied to the metastable ionization detector is then varied so as to maintain the detected signal level constant. The variation in ionization potential is now related to the concentration fo the constituent and a representative amplitude is applied to another input of said strip chart recorder.

Carle, G. C.; Humphry, D. E.; Kojiro, D. R.

1985-08-27T23:59:59.000Z

78

Liquid chromatographic extraction medium  

DOE Patents (OSTI)

A method and apparatus are disclosed for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water. 1 fig.

Horwitz, E.P.; Dietz, M.L.

1994-09-13T23:59:59.000Z

79

Liquid chromatographic extraction medium  

DOE Patents (OSTI)

A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

Horwitz, E. Philip (Naperville, IL); Dietz, Mark L. (Evanston, IL)

1994-01-01T23:59:59.000Z

80

Lorentz Connections and Gravitation  

E-Print Network (OSTI)

The different roles played by Lorentz connections in general relativity and in teleparallel gravity are reviewed. Some of the consequences of this difference are discussed.

J. G. Pereira

2012-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

FedConnect Instructions  

Energy.gov (U.S. Department of Energy (DOE))

Here are instructions to make it easier to locate Funding Opportunity Announcements (FOAs) for the Geothermal Technologies Office at the FedConnect Web site.

82

Carbon Connections | Open Energy Information  

Open Energy Info (EERE)

Product: Carbon Connections links partner universities with industry encouraging knowledge exchange and developing innovative ideas. References: Carbon Connections1 This...

83

A theoretical study of the incandescent filament lamp performance under voltage flicker  

SciTech Connect

Incandescent filament lamp flicker, produced by voltage fluctuation, is a power quality problem that caused engineering concern since the onset of electrical illumination technology. The flicker phenomenon was analyzed and explained in early studies. Standards dealing with acceptable flicker levels are well known, nevertheless, today the discussion about flicker continues to be a top priority topic due to the fact that steady-state and transient voltage waveform distortion is a growing problem in low and medium voltage systems. In many situations voltage flicker is caused by subharmonics and interharmonics of voltage. Cycloconverters, welders and arc furnaces, eccentrically operating tools and integral cycle controlled power equipment are notorious for producing voltage flicker. The goal of this paper is to provide solid mathematical basis for the analytical modeling of incandescent filament lamp flicker when the voltage is nonsinusoidal. A mathematical model that enables the evaluation of the luminous flux modulation caused by noninteger harmonics (subharmonics and interharmonics) is presented. Three situations are detailed: square-wave voltage modulation, sinusoidal modulation and the case of noninteger harmonics with nearly contiguous frequencies.

Peretto, L. [Univ. of Bologna (Italy)] [Univ. of Bologna (Italy); Emanuel, A.E. [Worcester Polytechnic Inst., MA (United States)] [Worcester Polytechnic Inst., MA (United States)

1997-01-01T23:59:59.000Z

84

IMPRESS CONNECT DOCUMENT ORDERING  

E-Print Network (OSTI)

IMPRESS CONNECT DOCUMENT ORDERING USER GUIDE FOR UNF August 2010 #12;OFFICEMAX IMPRESS CONNECT USERMax (case sensitive) Click on "Create New Custom Print Order" under Print & Document Services #12;The first landing page. You will see 3 options across the top of the landing page: Order Jobs, Track Jobs, Manage

Asaithambi, Asai

85

V-125: Cisco Connected Grid Network Management System Multiple  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: Cisco Connected Grid Network Management System Multiple 5: Cisco Connected Grid Network Management System Multiple Vulnerabilities V-125: Cisco Connected Grid Network Management System Multiple Vulnerabilities April 3, 2013 - 1:44am Addthis PROBLEM: Cisco Connected Grid Network Management System Multiple Vulnerabilities PLATFORM: Cisco Connected Grid Network Management System 2.x ABSTRACT: Some vulnerabilities have been reported in Cisco Connected Grid Network Management System. REFERENCE LINKS: Cisco Security Notice CVE-2013-1163 Cisco Security Notice CVE-2013-1171 Secunia Advisory SA52834 SecurityTracker Alert ID: 1028374 SecurityTracker Alert ID: 1028373 CVE-2013-1163 CVE-2013-1171 IMPACT ASSESSMENT: Medium DISCUSSION: 1) Certain input related to the element list component is not properly sanitised before being returned to the user. This can be exploited to

86

V-125: Cisco Connected Grid Network Management System Multiple  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: Cisco Connected Grid Network Management System Multiple 5: Cisco Connected Grid Network Management System Multiple Vulnerabilities V-125: Cisco Connected Grid Network Management System Multiple Vulnerabilities April 3, 2013 - 1:44am Addthis PROBLEM: Cisco Connected Grid Network Management System Multiple Vulnerabilities PLATFORM: Cisco Connected Grid Network Management System 2.x ABSTRACT: Some vulnerabilities have been reported in Cisco Connected Grid Network Management System. REFERENCE LINKS: Cisco Security Notice CVE-2013-1163 Cisco Security Notice CVE-2013-1171 Secunia Advisory SA52834 SecurityTracker Alert ID: 1028374 SecurityTracker Alert ID: 1028373 CVE-2013-1163 CVE-2013-1171 IMPACT ASSESSMENT: Medium DISCUSSION: 1) Certain input related to the element list component is not properly sanitised before being returned to the user. This can be exploited to

87

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents (OSTI)

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

1994-06-28T23:59:59.000Z

88

Automatic Voltage Control of Electrical Systems  

Science Journals Connector (OSTI)

... to have complete automatic voltage regulation and it also has supervisory control for its main substations. By a careful application of automatically controlled regulators it is shown that the voltage ...

1934-01-20T23:59:59.000Z

89

Implications of Pulser Voltage Ripple  

SciTech Connect

In a recent set of measurements obtained by G. Kamin, W. Manning, A. Molvik, and J. Sullivan, the voltage waveform of the diode pulser had a ripple of approximately {+-}1.3% of the 65 kV flattop voltage, and the beam current had a larger corresponding ripple of approximately {+-}8.4% of the 1.5 mA average current at the location of the second Faraday cup, approximately 1.9 m downstream from the ion source. The period of the ripple was about 1 {mu}s. It was initially unclear whether this large current ripple was in fact a true measurement of the current or a spurious measurement of noise produced by the pulser electronics. The purpose of this note is to provide simulations which closely match the experimental results and thereby corroborate the physical nature of those measurements, and to provide predictions of the amplitude of the current ripples as they propagate to the end of linear transport section. Additionally analytic estimates are obtained which lend some insight into the nature of the current fluctuations and to provide an estimate of what the maximum amplitude of the current fluctuations are expected to be, and conversely what initial ripple in the voltage source is allowed, given a smaller acceptable tolerance on the line charge density.

Barnard, J J

2011-12-21T23:59:59.000Z

90

Onset voltage of corona on coated conductors  

SciTech Connect

This paper is aimed for investigating the effect of surface coating on the positive and negative onset voltages of corona from stressed conductor as a pre-requisite for onset-voltage calculation. The electric field is accurately calculated by the charge simulation technique. The calculated onset voltages agreed satisfactorily with those measured experimentally for bare conductors. The effect of coating-layer thickness and permittivity as well as conductor radius and height on the onset-voltage values is discussed.

Abdel-Salam, M. [Assiut Univ. (Egypt). Electrical Engineering Dept.; Abo-Shal, Y. [SCECO-East, Dammam (Saudi Arabia). Electrical Engineering Div.

1995-12-31T23:59:59.000Z

91

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

1998-01-01T23:59:59.000Z

92

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

Druce, R.L.; Kirbie, H.C.; Newton, M.A.

1998-06-30T23:59:59.000Z

93

Dual-decay converter for switched reluctance motor drives in low-voltage applications  

SciTech Connect

A modified converter topology for star-connected switched reluctance motors suitable for low-voltage applications is proposed in this paper. A dual time constant freewheeling circuit has been designed to improve the drive performance and efficiency over a wide range of speeds. The different modes of operation of the converter are discussed, and a comparison is made with other converter configurations.

Ehsani, Mehrdad; Husain, Iqbal; Ramani, K.R. (Texas A and M Univ., College Station, TX (United States). Dept. of Electrical Engineering); Galloway, J.H. (J.H. Galloway and Associates, Brookfield, CT (United States))

1993-04-01T23:59:59.000Z

94

Connecting Stakeholders, Achieving Green  

E-Print Network (OSTI)

Partner Energy @ Work Toronto, Ontario Canada OCTOBER 2008, ESL-IC-08-10-71 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 Green Paper ? Working Paper Connecting... allows barriers to be overcome and benefits to be maximized. ESL-IC-08-10-71 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 Green Paper ? Working Paper Connecting...

Rouse, S.; Nolan, B.

95

Design of control circuit of grid-connected photovoltaic system based on SPMC75F2413A  

Science Journals Connector (OSTI)

This paper discusses the experimental design of a grid-*connected photovoltaic system based on 16-bit Microprocessor (MCU) SPMC75F2413A. In this paper, the SPMC75F2413A as the main topology control the main circuit of the Single-phase bridge type inverter. The system can track the maximum power point by detecting PV(photovoltaic) voltage, current and grid-connected output voltage and current, and simultaneously can track the frequency and phase by the software phase locked loop. The testing results of the grid-connected photovoltaic system shows that the grid-connected voltage and network voltage are synchronous, and the system is feasible and practical.

Ma Hongmei; Li Peng; Zhang Dan

2010-01-01T23:59:59.000Z

96

High voltage RF feedthrough bushing  

DOE Patents (OSTI)

Described is a multi-element, high voltage radio frequency bushing for trmitting RF energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.

Grotz, Glenn F. (Huntington Station, NY)

1984-01-01T23:59:59.000Z

97

STATCOM-based voltage and frequency regulator for stand-alone asynchronous generator  

Science Journals Connector (OSTI)

This paper presents a STATCOM-based voltage and frequency regulation for stand-alone asynchronous generator feeding linear and nonlinear loads. The SEIG have inherent poor voltage and frequency regulation. The voltage and frequency depend upon the load current and power factor of the load with fixed excitation capacitor employing unregulated turbines. The changing consumer load requires variable reactive power compensation for excitation requirement. Consumer load contains harmonics and performance of SEIG is largely affected by these load harmonics. A current controlled voltage source inverter working as STATCOM is used for harmonic elimination, load balancing and variable reactive power compensation. A DC chopper with dump load is connected across DC bus capacitor to regulate varying consumer load. The control algorithm has been first co-simulated with processor in the loop (PIL) and then experimentally validated. The transient behaviour of developed prototype system for application and removal of balanced, unbalanced, nonlinear load is investigated.

Dheeraj Kumar Palwalia

2014-01-01T23:59:59.000Z

98

Algebraic connectivity and graph robustness.  

SciTech Connect

Recent papers have used Fiedler's definition of algebraic connectivity to show that network robustness, as measured by node-connectivity and edge-connectivity, can be increased by increasing the algebraic connectivity of the network. By the definition of algebraic connectivity, the second smallest eigenvalue of the graph Laplacian is a lower bound on the node-connectivity. In this paper we show that for circular random lattice graphs and mesh graphs algebraic connectivity is a conservative lower bound, and that increases in algebraic connectivity actually correspond to a decrease in node-connectivity. This means that the networks are actually less robust with respect to node-connectivity as the algebraic connectivity increases. However, an increase in algebraic connectivity seems to correlate well with a decrease in the characteristic path length of these networks - which would result in quicker communication through the network. Applications of these results are then discussed for perimeter security.

Feddema, John Todd; Byrne, Raymond Harry; Abdallah, Chaouki T. (University of New Mexico)

2009-07-01T23:59:59.000Z

99

CMVRTC: Medium Truck Duty Cycle  

NLE Websites -- All DOE Office Websites (Extended Search)

medium truck duty cycle (MTdc) project medium truck duty cycle (MTdc) project OVERVIEW The Medium Truck Duty Cycle (MTDC) project involves efforts to collect, analyze and archive data related to medium-truck operations in real-world driving environments. Such data and information will be useful to support technology evaluation efforts and to provide a means of accounting for real-world driving performance within medium-class truck analyses. The project involves private industry partners from various truck vocations. The MTDC project is unique in that there currently does not exist a national database of characteristic duty cycles for medium trucks. This project involves the collection of data from multiple vocations (four vocations) and multiple vehicles within these vocations (three vehicles per

100

A novel voltage and frequency controller for standalone DFIG based Wind Energy Conversion System  

Science Journals Connector (OSTI)

Abstract This paper presents a new speed-sensorless control strategy for a stand-alone doubly-fed induction generator supplying energy to an isolated load. The method is based on the root mean square (rms) detection scheme. The generated stator voltage is controlled via rotor currents. Amplitude of stator voltage and its frequency are controlled simultaneously. The output signals from the voltage controllers are the reference signals for the rotor current amplitude and frequency of the stator voltage is regulated with the help of frequency control loop. This developed direct voltage control method is applicable for both the balanced and unbalanced load and also for standalone and grid connected mode. The control pulses for the rotor side converter is supplied by the hysteresis controller which is operated on the error signal calculated between actual and reference rotor currents. This paper also provides the brief idea about the voltage and frequency control on modern Autonomous DFIG based Wind Energy Systems via single phase mathematical model of standalone DFIG system. A short state-of-the-art review on mechanical position/speed sensorless control schemes for autonomous DFIG based \\{WESs\\} is presented, which helps the present researcher and students working in this area. These include stator flux oriented control techniques; direct voltage control techniques; MARS observer based techniques for autonomous DFIG-based variable-speed WESs. Simulation results obtained from a 2MVA DFIG system, prototype in MATLab/Simulink, are presented and discussed in this paper.

Rishabh Dev Shukla; Ramesh Kumar Tripathi

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Fiber optic current monitor for high-voltage applications  

DOE Patents (OSTI)

A current monitor which derives its power from the conductor being measured for bidirectionally measuring the magnitude of current (from DC to above 50 khz) flowing through a conductor across which a relatively high level DC voltage is applied, includes a pair of identical transmitter modules connected in opposite polarity to one another in series with the conductor being monitored, for producing from one module a first light signal having an intensity directly proportional to the magnitude of current flowing in one direction through the conductor during one period of time, and from the other module a second light signal having an intensity directly proportional to the magnitude of current flowing in the opposite direction through the conductor during another period of time, and a receiver located in a safe area remote from the high voltage area for receiving the first and second light signals, and converting the same to first and second voltage signals having levels indicative of the magnitude of current being measured at a given time.

Renda, George F. (Plainsboro, NJ)

1992-01-01T23:59:59.000Z

102

Connecting to NERSC  

NLE Websites -- All DOE Office Websites (Extended Search)

Transferring Data Transferring Data Network Performance Queues and Scheduling Job Logs & Analytics Training & Tutorials Software Accounts & Allocations Policies Data Analytics & Visualization Data Management Policies Science Gateways User Surveys NERSC Users Group User Announcements Help Operations for: Passwords & Off-Hours Status 1-800-66-NERSC, option 1 or 510-486-6821 Account Support https://nim.nersc.gov accounts@nersc.gov 1-800-66-NERSC, option 2 or 510-486-8612 Consulting http://help.nersc.gov consult@nersc.gov 1-800-66-NERSC, option 3 or 510-486-8611 Home » For Users » Network Connections » Connecting to NERSC Connecting to NERSC All NERSC computers (except HPSS) are reached using either the Secure Shell (SSH) communication and encryption protocol (version 2) or by Grid tools

103

Definition: Operating Voltage | Open Energy Information  

Open Energy Info (EERE)

Voltage Voltage Jump to: navigation, search Dictionary.png Operating Voltage The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related; also, the effective (root-mean-square) potential difference between any two conductors or between a conductor and the ground. The actual voltage of the circuit may vary somewhat above or below this value.[1] Related Terms system References ↑ Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Operating_Voltage&oldid=480559" Categories: Definitions ISGAN Definitions What links here Related changes

104

Wind Power Plant Voltage Stability Evaluation: Preprint  

SciTech Connect

Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

Muljadi, E.; Zhang, Y. C.

2014-09-01T23:59:59.000Z

105

Mobile Conference Connection Conferencing  

E-Print Network (OSTI)

Mobile Conference Connection Conferencing · Help increase productivity while out of the office-mail meeting invitations from your mobile device · Access to "Click to Join" features · Initiate an Instant or other mobile devices can provide a quick and efficient means to respond to work demands. But, what

106

High power connection system  

DOE Patents (OSTI)

A high power connection system adapted for automotive environments which provides environmental and EMI shielding includes a female connector, a male connector, and a panel mount. The female connector includes a female connector base and a snap fitted female connector cover. The male connector includes a male connector base and a snap fitted male connector cover. The female connector base has at least one female power terminal cavity for seatably receiving a respective female power terminal. The male connector base has at least one male power terminal cavity for seatably receiving a respective male power terminal. The female connector is covered by a cover seal and a conductive shroud. A pair of lock arms protrude outward from the front end of the male connector base, pass through the panel mount and interface with a lever of a lever rotatably connected to the shroud to thereby mechanically assist mating of the male and female connectors. Safety terminals in the male and female connectors provide a last-to-connect-first-to-break connection with an HVIL circuit.

Schaefer, Christopher E. (Warren, OH); Beer, Robert C. (Noblesville, IN); McCall, Mark D. (Youngstown, OH)

2000-01-01T23:59:59.000Z

107

Design of series-parallel connected thermionic converter arrays  

SciTech Connect

Applications of thermionic converters require that a large number of converters be connected together in a series-parallel array in order to provide a useful output voltage. Such an array also serves to insure a very high overall system reliability, despite possible failures of individual converters. This paper predicts the effects of a nonuniform distribution of input power on the performance of such an array. 9 refs.

Mcvey, J.B.; Britt, E.J.; Fitzpatrick, G.O.; Dick, R.S.

1981-01-01T23:59:59.000Z

108

Medium Truck Duty Cycle (MTDC)  

NLE Websites -- All DOE Office Websites (Extended Search)

Routes Data Acquisition System Setup Routes Data Acquisition System Setup Medium Truck Duty Cycle (MTDC) Objective This Department of Energy project focuses on the collection and analysis medium truck (Class-6 and -7) duty cycle data from real-world operations. Analysis of this data will provide information pertaining to the fuel efficiencies and performance of medium trucks in several vocations. Outcomes Rich source of data and information that can contribute to the development of new tools Sound basis upon which DOE can make technology investment decisions A national archive of real-world-based medium-truck operational data that will support medium-duty vehicle energy efficiency research Collected Data Speed & Acceleration Fuel Consumption GPS Location Road Grade

109

Group 3: Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect

Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-05-01T23:59:59.000Z

110

High Voltage Electrolyte for Lithium Batteries  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

battery using high voltage high energy cathode materials to enable large-scale, cost competitive production of the next generation of electric-drive vehicles. To...

111

Optimal Placement of Wind Generators in Medium Voltage Power Grids -- Investigations of Genetic Algorithm  

Science Journals Connector (OSTI)

The paper presents investigations of a genetic algorithm for computations of power losses in the MV power grid. In this case, the vector of start population PO0 and mutation likelihood was investigated. Diagrams of power losses in the grid dependent ... Keywords: genetic algorithm, wind generators, power grid, parallel processing, MPI

Andrzej Jordan; Carsten Maple; Ryszard Szczebiot; Lukasz Swierczewski

2011-04-01T23:59:59.000Z

112

Medium Voltage Overhead Power-line Broadband Communications; Transmission Capacity and Electromagnetic Interference  

E-Print Network (OSTI)

and Electromagnetic Interference P. Amirshahi and M. Kavehrad (FIEEE) The Pennsylvania State University, Department distribution networks for broadband power-line communications applications. Electromagnetic interference

Kavehrad, Mohsen

113

Performance of reduced wall EPR insulated medium voltage power cables. Part 2: Mechanical characteristics  

SciTech Connect

For the replacement of paper insulated lead covered cables (PILC) reduced insulation wall designs have been developed. They provide a reliable lower diameter cable design for installation in existing PILC conduits. Representing Part 2 of the investigation, this paper presents the results of mechanical testing conducted on both reduced and full wall EPR insulated cables. Both jacketed and non-jacketed cable designs have been subjected to mechanical pulling forces which greatly exceed recommended industry limitations, followed by electrical testing to ascertain cable performance. The results of this study conclude that reduced wall EPR insulated cables can safely withstand the same pulling forces as recommended for conventional walls and can be designed for installation under the same pulling limitations.

Wen, Y.; Cinquemani, P.L. [Pirelli Cable Corp., Lexington, SC (United States)

1997-04-01T23:59:59.000Z

114

Performance of reduced wall EPR insulated medium voltage power cables. Pat 1: Electrical characteristics  

SciTech Connect

Paper insulated lead covered cables (PILC) have had a long and successful heritage. After almost 100 years, this design of cable is still in operation and continues to be manufactured. However, utilities are now looking for a reliable replacement for PILC cables. This is due to two primary reasons: (1) difficulty in installing and maintaining this type of cable and (2) increasing pressure to replace these cables due to environmental concerns. To date diameter limitations of conventional extruded dielectric cables has impeded their replacement in existing PILC conduits. This paper describes a study for the evaluation for reliably reducing the insulation thickness to achieve a lower diameter cable to effectively replace PILC cable in existing conduits. Part 1 of the investigation reviews the theory of insulation wall determination and the test program carried out to evaluate electrical performance of reduced wall EPR cables. Additionally, cable design concepts and constructions are discussed. In Part 2 the mechanical performance on conventional and reduced wall EPR insulated cables are evaluated. This is reported in a separate paper.

Cinquemani, P.L.; Wen, Y.; Kuchta, F.L.; Doench, C. [Pirelli Cable Corp., Lexington, SC (United States)] [Pirelli Cable Corp., Lexington, SC (United States)

1997-04-01T23:59:59.000Z

115

Abb Inc. medium-voltage products' supply chain analysis, including inventory, supplier scorecard, and risk assessments  

E-Print Network (OSTI)

In conformance with ABB's process excellence plan, this thesis study was undertaken to support improvements in on-time delivery of components, decreased order cycles, and reduced inventory levels for ADVAC (spring-mechan ...

Gaskins, Tamboura E. (Tamboura Elyse)

2006-01-01T23:59:59.000Z

116

Method and apparatus for remote tube crevice detection by current and voltage probe resistance measurement  

DOE Patents (OSTI)

A method and apparatus for determining the extent of contact between an electrically conducting tube and an electrically conductive tubesheet surrounding the tube, based upon the electrical resistance of the tube and tubesheet. A constant current source is applied to the interior of the electrically conducting tube by probes and a voltmeter is connected between other probes to measure the voltage at the point of current injection, which is inversely proportional to the amount of contact between the tube and tubesheet. Namely, the higher the voltage measured by the voltmeter, the less contact between the tube and tubesheet. 4 figs.

Kikta, T.J.; Mitchell, R.D.

1992-11-24T23:59:59.000Z

117

Method and apparatus for remote tube crevice detection by current and voltage probe resistance measurement  

DOE Patents (OSTI)

A method and apparatus for determining the extent of contact between an electrically conducting tube and an electrically conductive tubesheet surrounding the tube, based upon the electrical resistance of the tube and tubesheet. A constant current source is applied to the interior of the electrically conducting tube by probes and a voltmeter is connected between other probes to measure the voltage at the point of current injection, which is inversely proportional to the amount of contact between the tube and tubesheet. Namely, the higher the voltage measured by the voltmeter, the less contact between the tube and tubesheet.

Kikta, Thomas J. (Pittsburgh, PA); Mitchell, Ronald D. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

118

Medium Modifications of Hadron Properties and Partonic Processes  

E-Print Network (OSTI)

Chiral symmetry is one of the most fundamental symmetries in QCD. It is closely connected to hadron properties in the nuclear medium via the reduction of the quark condensate , manifesting the partial restoration of chiral symmetry. To better understand this important issue, a number of Jefferson Lab experiments over the past decade have focused on understanding properties of mesons and nucleons in the nuclear medium, often benefiting from the high polarization and luminosity of the CEBAF accelerator. In particular, a novel, accurate, polarization transfer measurement technique revealed for the first time a strong indication that the bound proton electromagnetic form factors in 4He may be modified compared to those in the vacuum. Second, the photoproduction of vector mesons on various nuclei has been measured via their decay to e+e- to study possible in-medium effects on the properties of the rho meson. In this experiment, no significant mass shift and some broadening consistent with expected collisional broa...

Brooks, W K; Tsushima, K

2011-01-01T23:59:59.000Z

119

Librarian Research Connection Widget  

Office of Scientific and Technical Information (OSTI)

Get the Librarian Research Connection widget and many other great free Get the Librarian Research Connection widget and many other great free widgets at Widgetbox! Access-at one place, all-in-one widget, right at your fingertips-a variety of scientific and technical information sources from the U.S. Department of Energy (DOE) Office of Scientific and Technical Information (OSTI). Help your patron: Included are search capabilities for full-text DOE documents at Information Bridge, DOE resources at Science Accelerator, U.S. government science at Science.gov, and international science at WorldWideScience.org. Spark further scientific discovery by providing your researchers with the scientific and technical information your colleagues are using. Just view the most downloaded documents (monthly) at OSTI or browse the most popular OSTI subject categories and their related documents.

120

University Connections | .EDUconnections  

Office of Scientific and Technical Information (OSTI)

Research on the "Go" with OSTI mobile Research on the "Go" with OSTI mobile Research on the "Go" with OSTI mobile Get the EDUconnections widget and many other great free widgets at Widgetbox! University Spotlight Program The U.S. Department of Energy (DOE) Office of Scientific and Technical Information (OSTI) connects with university research departments and libraries across the nation to increase awareness of DOE's valuable scientific and technical information. OSTI "spotlights" individual universities with connections to DOE scientific research programs. Visit our spotlight below to see examples of universities that are supporting and advancing scientific research and discovery! University Spotlight Visit our Spotlight Archive to learn about great colleges and universities

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Connections: August 2013  

NLE Websites -- All DOE Office Websites (Extended Search)

August 2013 August 2013 Community Connections: Our link to Northern New Mexico Communities Latest Issue:Dec. 2013 - Jan. 2014 All Issues » submit IN THIS ISSUE As summer turns to fall, a new school year begins Welcome to the back-to-school issue of Community Connections Celebrating the Lab's 70th Anniversary Activities centered on the week of July 22 Two new exhibits open at the Bradbury Science Museum Nanotechnology and algae biofuels Safeguarding wetland on Laboratory property Protecting our environment For your calendar Talks on science, history, fun with robots and renewable energy resources for small business In other news New Mexico small businesses can submit leveraged proposals beginning August 20 Get updates on LANL Environmental Programs - Click to subscribe Los Alamos wins three R&D 100 awards

122

DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION  

E-Print Network (OSTI)

1 DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION In this paper the design and implementation of a fuzzy logic-based controller is described for regulating the output voltage of a synchronous generator. An automated fuzzy logic-based control strategy is presented

LaMeres, Brock J.

123

CURRENT SOURCING ISOLATED GRID CONNECTED INVERTER Ilya Zeltser, Student Member, IEEE and Sam Ben-Yaakov, Senior Member, IEEE  

E-Print Network (OSTI)

CURRENT SOURCING ISOLATED GRID CONNECTED INVERTER Ilya Zeltser, Student Member, IEEE and Sam Ben proposes a soft switched Output Current Sourcing (OCS) grid connected inverter that applies a high inverters where the small disturbance at the line voltage may lead to current run away and consequently

124

Development of High Voltage Electron Microscope  

Science Journals Connector (OSTI)

......Cockcroft Walton Type High Voltage Generator. O Power Line O Fig. 4...pressure in the tank to the atmospheric pressure by removing freon...pump using liquid nitrogen. Water buffer and liquid nitrogen...base plate of high voltage generator. Four poles stand on this......

Shinjiro KATAGIRI; Hirokazu KIMURA; Susumu OZASA; Kazumi SHIRAISHI

1969-01-01T23:59:59.000Z

125

Voltage regulation in linear induction accelerators  

DOE Patents (OSTI)

Improvement in voltage regulation in a Linear Induction Accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance.

Parsons, William M. (Santa Fe, NM)

1992-01-01T23:59:59.000Z

126

Voltage regulation in linear induction accelerators  

DOE Patents (OSTI)

Improvement in voltage regulation in a linear induction accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core is disclosed. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance. 4 figs.

Parsons, W.M.

1992-12-29T23:59:59.000Z

127

Limitations of High-Voltage Insulation  

Science Journals Connector (OSTI)

... materials such as impregnated paper. The important electrical properties of the materials used for the insulation of high-voltage circuits are conductivity and electric strength. The conductivity measures the ability ... a million times between themselves, but they are all classified as available for high-voltage insulation.

1938-01-08T23:59:59.000Z

128

NREL: Measurements and Characterization - Current Versus Voltage  

NLE Websites -- All DOE Office Websites (Extended Search)

Current Versus Voltage Current Versus Voltage The National Renewable Energy Laboratory (NREL) Device Performance group uses current versus voltage (I-V) measurement systems to assess the main performance parameters for photovoltaic (PV) cells and modules. I-V measurement systems determine the output performance of devices, including: open-circuit voltage (Voc), short-circuit current (Isc), fill factor (FF), maximum power output of the device (Pmax), voltage at maximum power (Vmax), current at maximum power (Imax), and conversion efficiency of the device (η). Some I-V systems may also be used to perform dark I-V measurements to determine diode properties and series and shunt resistances. We use three I-V systems to measure performance of individual PV cells; and four for modules - two for measurements under simulated conditions; and

129

High Voltage Safety Act | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High Voltage Safety Act High Voltage Safety Act High Voltage Safety Act < Back Eligibility Commercial Construction Developer General Public/Consumer Industrial Installer/Contractor Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Safety and Operational Guidelines Siting and Permitting The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage electric lines by providing that no work shall be done in the vicinity of such lines unless and until the owner or operator thereof has been notified of such work and has taken the appropriate safety measures. The Georgia Public Service Commission requires

130

Non-contact current and voltage sensor  

DOE Patents (OSTI)

A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

2014-03-25T23:59:59.000Z

131

Electro-optical voltage sensor head  

DOE Patents (OSTI)

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID)

1998-01-01T23:59:59.000Z

132

Acta Phys. Hung. A 19/1 (2004) 000{000 In-medium properties of nucleon resonances  

E-Print Network (OSTI)

side: vacuum, right hand side: in the nuclear medium [5] In-medium modi#12;cations of mesons will also of the MAMI accelerator in Mainz. Measured was the photoproduction of mesons (#12;nal states #25; o X , #17;X is spontaneously broken. This is connected to a non-zero expectation value of scalar q#22;q pairs in the vacuum

Krusche, Bernd

133

Medium Modifications of Hadron Properties and Partonic Processes  

E-Print Network (OSTI)

Chiral symmetry is one of the most fundamental symmetries in QCD. It is closely connected to hadron properties in the nuclear medium via the reduction of the quark condensate , manifesting the partial restoration of chiral symmetry. To better understand this important issue, a number of Jefferson Lab experiments over the past decade have focused on understanding properties of mesons and nucleons in the nuclear medium, often benefiting from the high polarization and luminosity of the CEBAF accelerator. In particular, a novel, accurate, polarization transfer measurement technique revealed for the first time a strong indication that the bound proton electromagnetic form factors in 4He may be modified compared to those in the vacuum. Second, the photoproduction of vector mesons on various nuclei has been measured via their decay to e+e- to study possible in-medium effects on the properties of the rho meson. In this experiment, no significant mass shift and some broadening consistent with expected collisional broadening for the rho meson has been observed, providing tight constraints on model calculations. Finally, processes involving in-medium parton propagation have been studied. The medium modifications of the quark fragmentation functions have been extracted with much higher statistical accuracy than previously possible.

W. K. Brooks; S. Strauch; K. Tsushima

2011-04-11T23:59:59.000Z

134

Connectivity-based garbage collection  

Science Journals Connector (OSTI)

We introduce a new family of connectivity-based garbage collectors (Cbgc) that are based on potential object-connectivity properties. The key feature of these collectors is that the placement of objects into partitions is determined by performing ... Keywords: connectivity based garbage collection

Martin Hirzel; Amer Diwan; Matthew Hertz

2003-11-01T23:59:59.000Z

135

Researchers map atomic movements that trigger voltage fade in...  

NLE Websites -- All DOE Office Websites (Extended Search)

map atomic movements that trigger voltage fade in high-energy-density batteries January 22, 2015 Voltage and capacity curves from an LMR-NMC high-energy cathode show voltage fade...

136

Real Power and Reactive Power Control of a Three-Phase Single-Stage-PV System and PV voltage Stability  

SciTech Connect

Grid-connected photovoltaic (PV) systems with power electronic interfaces can provide both real and reactive power to meet power system needs with appropriate control algorithms. This paper presents the control algorithm design for a three-phase single-stage grid-connected PV inverter to achieve either maximum power point tracking (MPPT) or a certain amount of real power injection, as well as the voltage/var control. The switching between MPPT control mode and a certain amount of real power control mode is automatic and seamless. Without the DC-to-DC booster stage, PV DC voltage stability is an important issue in the control design especially when the PV inverter is operating at maximum power point (MPP) with voltage/var control. The PV DC voltage collapse phenomenon and its reason are discussed. The method based on dynamic correction of the PV inverter output is proposed to ensure PV DC voltage stability. Simulation results of the single-stage PV system during system disturbances and fast solar irradiation changes confirm that the proposed control algorithm for single-stage PV inverters can provide appropriate real and reactive power services and ensure PV DC voltage stability during dynamic system operation and atmospheric conditions.

Li, Huijuan [ORNL] [ORNL; Xu, Yan [ORNL] [ORNL; Adhikari, Sarina [ORNL] [ORNL; Rizy, D Tom [ORNL] [ORNL; Li, Fangxing [ORNL] [ORNL; Irminger, Philip [ORNL] [ORNL

2012-01-01T23:59:59.000Z

137

Property:Nominal Voltage | Open Energy Information  

Open Energy Info (EERE)

Nominal Voltage Nominal Voltage Jump to: navigation, search Property Name Nominal Voltage Property Type Number This is a property of type Number. Pages using the property "Nominal Voltage" Showing 22 pages using this property. D Distributed Generation Study/10 West 66th Street Corp + 480 + Distributed Generation Study/615 kW Waukesha Packaged System + 480 + Distributed Generation Study/Aisin Seiki G60 at Hooligans Bar and Grille + 240 + Distributed Generation Study/Arrow Linen + 480 + Distributed Generation Study/Dakota Station (Minnegasco) + 0 + Distributed Generation Study/Elgin Community College + 4,160 + Distributed Generation Study/Emerling Farm + 480 + Distributed Generation Study/Floyd Bennett + 480 + Distributed Generation Study/Harbec Plastics + 480 +

138

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, R.S.

1985-08-05T23:59:59.000Z

139

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile. 2 figs.

Hawke, R.S.

1987-11-17T23:59:59.000Z

140

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, Ronald S. (Livermore, CA)

1987-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Modular high voltage power supply for chemical analysis  

DOE Patents (OSTI)

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2010-05-04T23:59:59.000Z

142

DC transformer for DC/DC connection in HVDC network M. Jimenez Carrizosa1, A. Benchaib2, P. Alou3, G. Damm4  

E-Print Network (OSTI)

DC transformer for DC/DC connection in HVDC network M. Jim´enez Carrizosa1, A. Benchaib2, P. Alou3>>, >, HVDC>>, > . Abstract This paper presents the modeling and control for the integration of an offshore wind farm in a High Voltage Direct Current (HVDC). Until developed of VSC (voltage

Paris-Sud XI, Université de

143

Constant voltage electro-slag remelting control  

DOE Patents (OSTI)

A system for controlling electrode gap in an electro-slag remelt furnace has a constant regulated voltage and an electrode which is fed into the slag pool at a constant rate. The impedance of the circuit through the slag pool is directly proportional to the gap distance. Because of the constant voltage, the system current changes are inversely proportional to changes in gap. This negative feedback causes the gap to remain stable. 1 fig.

Schlienger, M.E.

1996-10-22T23:59:59.000Z

144

Connections: November 2013  

NLE Websites -- All DOE Office Websites (Extended Search)

Community Connections: Our link to Northern New Mexico Communities Latest Issue:Dec. 2013 - Jan. 2014 All Issues » submit IN THIS ISSUE Ribbon cutting marks chemistry laboratory upgrades at Northern New Mexico College Los Alamos National Security, LLC provides support Lab transitions employee giving campaigns This year's theme: "I Give Because..." Lab provides environmental support for county construction projects A face-lift for Ashley Pond New gamma-ray observatory begins operations at Sierra Negra volcano in the state of Puebla, Mexico The High-Altitude Water Cherenkov Gamma-Ray Observatory has begun formal operations 20/20 Campaign announces winners Companies recognized for fostering regional growth Lab supports multiethnic science careers Pilot program prepares regional students for national conference

145

Power converter connection configuration  

DOE Patents (OSTI)

EMI shielding is provided for power electronics circuits and the like via a direct-mount reference plane support and shielding structure. The thermal support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support forms a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.

Beihoff, Bruce C. (Wauwatosa, WI); Kehl, Dennis L. (Milwaukee, WI); Gettelfinger, Lee A. (Brown Deer, WI); Kaishian, Steven C. (Milwaukee, WI); Phillips, Mark G. (Brookfield, WI); Radosevich, Lawrence D. (Muskego, WI)

2008-11-11T23:59:59.000Z

146

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...

147

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2013 DOE Hydrogen and Fuel Cells Program and...

148

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2012 DOE Hydrogen and Fuel Cells Program and...

149

Cathode Synthesis and Voltage Fade: Designed Solutions Based...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cathode Synthesis and Voltage Fade: Designed Solutions Based on Theory Cathode Synthesis and Voltage Fade: Designed Solutions Based on Theory 2013 DOE Hydrogen and Fuel Cells...

150

Optimal Voltage Control of the Southern Norwegian Power Grid.  

E-Print Network (OSTI)

??This thesis contains the synthesis, analysis and simulation results of an automatic optimal voltage controller for the Southern Norwegian power grid. Currently the high voltage… (more)

Hannisdal, Erik Lundegaard

2011-01-01T23:59:59.000Z

151

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2013 DOE...

152

High voltage overhead long transmission line design and fault analysis.  

E-Print Network (OSTI)

??The goal of this project is to design a reliable high voltage overhead long transmission line that satisfies specific design criteria including voltage regulation, efficiency,… (more)

Elzain, Mohamed Ali

2011-01-01T23:59:59.000Z

153

SciTech Connect: The SciTech Connect Transition  

Office of Scientific and Technical Information (OSTI)

The SciTech Connect Transition The SciTech Connect Transition The SciTech Connect Transition Now you can visit one site for all the great science information previously searchable in the Energy Citations Database (ECD) and the Information Bridge (IB). ECD will no longer be available beginning August 28, 2013. IB will no longer be available beginning September 18, 2013. SciTech Connect provides access to all the information available via ECD and IB. The basic search at SciTech Connect employs an innovative semantic search capability to help you retrieve more relevant information. You can sign up for an account at SciTech and take advantage of extensive customization features. Don't forget to update your bookmarks! For more details, read OSTI Launches SciTech Connect, Consolidates Information Bridge and Energy Citations Database.

154

Considerations Related to Connecting Solar Generating Facilities to the Electrical Grid  

E-Print Network (OSTI)

Considerations Related to Connecting Solar Generating Facilities to the Electrical Grid March 2011 voltages are nominally 4.5kv and 13 2kv The solar system must maintain voltageand 13.2kv. The solar system) or multiple sites (multiple leases, interconnect points, construction forces) Ground based, roof top (weight

Homes, Christopher C.

155

MODULAR MULTI-LEVEL CONVERTER BASED HVDC SYSTEM FOR GRID CONNECTION OF OFFSHORE WIND  

E-Print Network (OSTI)

MODULAR MULTI-LEVEL CONVERTER BASED HVDC SYSTEM FOR GRID CONNECTION OF OFFSHORE WIND POWER PLANT U off-shore wind power plants. The MMC consists of a large number of simple voltage sourced converter offshore wind power plants (WPP) because they offer higher energy yield due to a superior wind profile

Chaudhary, Sanjay

156

SciTech Connect: Your connection to science, technology, and...  

NLE Websites -- All DOE Office Websites (Extended Search)

Your connection to science, technology, and engineering research information from the U.S. Department of Energy Search records with electronic full text Full Text Search citation...

157

High voltage power supply with modular series resonant inverters  

DOE Patents (OSTI)

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

Dreifuerst, Gary R. (Livermore, CA); Merritt, Bernard T. (Livermore, CA)

1995-01-01T23:59:59.000Z

158

High voltage power supply with modular series resonant inverters  

DOE Patents (OSTI)

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.

Dreifuerst, G.R.; Merritt, B.T.

1995-07-18T23:59:59.000Z

159

TE Connectivity Finds Answers in Tomography  

NLE Websites -- All DOE Office Websites (Extended Search)

TE Connectivity Finds Answers in Tomography TE Connectivity Finds Answers in Tomography Print Thursday, 22 August 2013 10:50 TE Connectivity is a world leader in connectivity-the...

160

Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics  

SciTech Connect

This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

Liu, E.; Bebic, J.

2008-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Making the Connection: Beneficial Collaboration Between Army...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Making the Connection: Beneficial Collaboration Between Army Installations and Energy Utility Companies Making the Connection: Beneficial Collaboration Between Army Installations...

162

Physical simulation study of dynamic voltage instability  

SciTech Connect

This paper presents a physical simulation of the dynamic behavior of voltage instability in an interconnected multimachine environment. The dynamic evolving process leading to eventual voltage collapse, the scenario of the progressive reactive support reduction resulting from the MXL protection relays, the OLTC operation, and the effect of switched-in capacitor banks are examined using physical facilities in the laboratory. The physical simulation results are also compared with digital simulation results. This physical investigation provides a reliable foundation for the effective development of assessment approaches and countermeasures.

Tso, S.K.; Zhu, T.X. [Univ. of Hong Kong (Hong Kong); Zeng, Q.Y. [Electric Power Research Inst., Beijing (China); Lo, K.L. [Univ. of Strathclyde, Glasgow (United Kingdom). Dept. of Electrical and Electrical Engineering

1995-12-31T23:59:59.000Z

163

CALIFORNIA ENERGY Market Connections Report  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Market Connections Report ConsultantReport Integrated Energy Systems & Associates. #12;Market Connections Report Preface 2 Preface The Public Interest Energy Research (PIER: Productivity and Building Science October 2003 500-03-082-A-1 Gray Davis, Governor #12;#12;CALIFORNIA ENERGY

164

Connecting PHP and PHP Loops  

E-Print Network (OSTI)

Connecting PHP and MySQL 1 #12;Outline · PHP Loops · PHPMyAdmin · Introducing SQL · Connecting Database from PHP · Exercises 2 #12;Loops · A loop statement is a control structure that repeatedly PHP supports the C style while loop ­ The body of the cycle

Graham, Nick

165

SciTech Connect: FAQ  

Office of Scientific and Technical Information (OSTI)

Frequently Asked Questions Frequently Asked Questions Frequently Asked Questions What is SciTech Connect? SciTech Connect is a portal to free, publicly-available DOE-sponsored R&D results including technical reports, bibliographic citations, journal articles, conference papers, books, multimedia and data information. SciTech Connect is a consolidation of two core DOE search engines, the Information Bridge and the Energy Citations Database. SciTech Connect incorporates all of the R&D information from these two products into one search interface. SciTech Connect was developed by the U.S. Department of Energy (DOE) Office of Scientific and Technical Information (OSTI) to increase access to science, technology, and engineering research information from DOE and its predecessor agencies.

166

SciTech Connect: FAQ  

Office of Scientific and Technical Information (OSTI)

Frequently Asked Questions Frequently Asked Questions Frequently Asked Questions What is SciTech Connect? SciTech Connect is a portal to free, publicly-available DOE-sponsored R&D results including technical reports, bibliographic citations, journal articles, conference papers, books, multimedia and data information. SciTech Connect is a consolidation of two core DOE search engines, the Information Bridge and the Energy Citations Database. SciTech Connect incorporates all of the R&D information from these two products into one search interface. SciTech Connect was developed by the U.S. Department of Energy (DOE) Office of Scientific and Technical Information (OSTI) to increase access to science, technology, and engineering research information from DOE and its predecessor agencies.

167

Electro-optic voltage sensor for sensing voltage in an E-field  

DOE Patents (OSTI)

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID); Renak, Todd W. (Idaho Falls, ID)

1999-01-01T23:59:59.000Z

168

V-134: Cisco AnyConnect Secure Mobility Client Heap Overflow Lets Local  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4: Cisco AnyConnect Secure Mobility Client Heap Overflow Lets 4: Cisco AnyConnect Secure Mobility Client Heap Overflow Lets Local Users Gain Elevated Privileges V-134: Cisco AnyConnect Secure Mobility Client Heap Overflow Lets Local Users Gain Elevated Privileges April 15, 2013 - 1:30am Addthis PROBLEM: Cisco AnyConnect Secure Mobility Client Heap Overflow Lets Local Users Gain Elevated Privileges PLATFORM: Cisco AnyConnect Secure Mobility Client Cisco Secure Desktop ABSTRACT: Some vulnerabilities were reported in Cisco AnyConnect Secure Mobility Client. REFERENCE LINKS: Cisco Security Notice CVE-2013-1172 Cisco Security Notice CVE-2013-1173 SecurityTracker Alert ID: 1028425 CVE-2013-1172 CVE-2013-1173 IMPACT ASSESSMENT: Medium DISCUSSION: A local user can trigger a heap overflow in the Cisco Host Scan component to execute arbitrary code on the target system with System privileges

169

Electro-optic high voltage sensor  

DOE Patents (OSTI)

A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal having at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

Davidson, James R. (Idaho Falls, ID); Seifert, Gary D. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

170

Distribution System Voltage Regulation by Distributed Energy Resources  

SciTech Connect

This paper proposes a control method to regulate voltages in 3 phase unbalanced electrical distribution systems. A constrained optimization problem to minimize voltage deviations and maximize distributed energy resource (DER) active power output is solved by harmony search algorithm. IEEE 13 Bus Distribution Test System was modified to test three different cases: a) only voltage regulator controlled system b) only DER controlled system and c) both voltage regulator and DER controlled system. The simulation results show that systems with both voltage regulators and DER control provide better voltage profile.

Ceylan, Oguzhan [ORNL; Liu, Guodong [ORNL; Xu, Yan [ORNL; Tomsovic, Kevin [University of Tennessee, Knoxville (UTK)

2014-01-01T23:59:59.000Z

171

Consumer Connection | Open Energy Information  

Open Energy Info (EERE)

Consumer Connection Consumer Connection Jump to: navigation, search Return to Connections to Energy Use Data and Information Page Consumers - please provide comments We are interested in finding out what you, as a residential or commercial consumer, think about gaining access to your energy use data. Please provide us with your thoughts on the results of the Utility data access map, describe how you currently use (or would like to use) energy data to make informed decisions about your energy use, or simply ask us a question. We look forward to hearing from you. Please enable JavaScript to view the comments powered by Disqus.comments powered by Disqus Retrieved from "http://en.openei.org/w/index.php?title=Consumer_Connection&oldid=413979" Category: UAM What links here

172

Utility Connection | Open Energy Information  

Open Energy Info (EERE)

Utility Connection Utility Connection Jump to: navigation, search Return to Connections to Energy Use Data and Information Page Please tell us how connected you are to your customers Thank you for taking the time to complete this questionnaire! As you know, utility data is very important and, if used correctly, can educate consumers and change their behavior to save money and energy. First select your utility company, then provide us a little information about yourself. Only one person from each utility can answer these questions and the results from your input will be shown on the Utility Data Accessibility Map. If the questionnaire has already been completed for your utility and you think the answers need to be changed, or if you are having trouble accessing your questionnaire, please contact the .

173

MagLab - Connect & Contact  

NLE Websites -- All DOE Office Websites (Extended Search)

or other media, we want to connect with you. Here are ways to stay in touch: Twitter icon Follow us on Twitter Facebook icon Follow us on Facebook YouTube icon Watch us on...

174

Mapping onto mesh connected multiprocessors  

E-Print Network (OSTI)

MAPPING ONTO MESH CONNECTED MULTIPROCESSORS A Thesis by PRASHANT L. HANGAL Submitted to the Office of Graduate Studies of Texas A@M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE December 1993... Major Subject: Computer Science MAPPING ONTO MESH CONNECTED MULTIPROCESSORS A Thesis by PRASHANT L. HANGAL Submitted to the Office of Graduate Studies of Texas A3rM University in partial fulfillment of the requirements for the degree of MASTER...

Hangal, Prashant L

2012-06-07T23:59:59.000Z

175

Derivation of the open-circuit voltage of organic solar cells  

Science Journals Connector (OSTI)

Organic photovoltaic cells have improved in efficiency from 1% two decades ago to over 10% today. Continued improvement necessitates a theoretical understanding of the factors determining efficiency. Organic photovoltaic efficiency can be parameterized in terms of open-circuit voltage, short-circuit current, and fill factor. Here we present a theory that explains the dependencies of open-circuit voltage on semiconductor energy levels, light intensity, solar cell and light-source temperatures, charge-carrier recombination, and external fluorescence efficiency. The present theory also explains why recombination at the donor-acceptor heterointerface is a dominant process in heterojunction-based cells. Furthermore, the Carnot efficiency appears, highlighting the connection to basic thermodynamics. The theory presented here is consistent with and builds on the experimental and theoretical observations already in the literature. Crucially, the present theory can be straightforwardly derived in a line-by-line fashion using standard tools from statistical physics.

Douglas B. Staple; Patricia A. K. Oliver; Ian G. Hill

2014-05-20T23:59:59.000Z

176

Sacramento Area Voltage Support Environmental Impact Statement  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

E E R R A N E V A D A R E G I O N Sacramento Area Voltage Support DRAFT ENVIRONMENTAL IMPACT STATEMENT DRAFT ENVIRONMENTAL IMPACT STATEMENT DOE/EIS-0323 NOVEMBER 2002 COVER SHEET Title: Sacramento Area Voltage Support Draft Environmental Impact Statement (EIS) Lead Agency: Western Area Power Administration (Western) Location: Alameda, Contra Costa, Placer, Sacramento, San Joaquin, and Sutter Counties, State of California. EIS Number: DOE/EIS-0323 Contact: Ms. Loreen McMahon, Environmental Project Manager Western Area Power Administration Sierra Nevada Region 114 Parkshore Drive Folsom, CA 95630 (916) 353-4460 (916) 985-1936 fax email: mcmahon@wapa.gov Website: Information is also available on our website: www.wapa.gov Hotline: 1-877-913-4440 (toll-free) Abstract The Western Area Power Administration's Central Valley Project transmission system forms an integral part of

177

High voltage electric substation performance in earthquakes  

SciTech Connect

This paper examines the performance of several types of high voltage substation equipment in past earthquakes. Damage data is provided in chart form. This data is then developed into a tool for estimating the performance of a substation subjected to an earthquake. First, suggests are made about the development of equipment class fragility curves that represent the expected earthquake performance of different voltages and types of equipment. Second, suggestions are made about how damage to individual pieces of equipment at a substation likely affects the post-earthquake performance of the substation as a whole. Finally, estimates are provided as to how quickly a substation, at various levels of damage, can be restored to operational service after the earthquake.

Eidinger, J. [G and E Engineering Systems, Oakland, CA (United States); Ostrom, D. [Southern California Edison, Rosemead, CA (United States); Matsuda, E. [Pacific Gas and Electric, San Francisco, CA (United States)

1995-12-31T23:59:59.000Z

178

Superconducting Fault Current Limiter for Transmission Voltage  

Science Journals Connector (OSTI)

Within a collaboration of American Superconductor, Siemens, Nexans and Southern California Edison one electrical phase of a resistive superconducting fault current limiter for the 115 kV transmission voltage level has been designed and manufactured. The active part of the limiter consists of 63 bifilar coils made of 12 mm wide steel-stabilized YBCO conductor and is housed in a cryostat operated at 5 bar and 74 K. The first phase was completely assembled and successfully subjected to power switching tests and high voltage tests. The basic design of the system and the test results are reported. The work was funded in part by US-DOE under Contract Number DE-FC26-07NT43243.

Hans-Peter Kraemer; Wolfgang Schmidt; Hong Cai; Bruce Gamble; David Madura; Tim MacDonald; Joe McNamara; Walther Romanosky; Greg Snitchler; Nicolas Lallouet; Frank Schmidt; Syed Ahmed

2012-01-01T23:59:59.000Z

179

Electrical system architecture having high voltage bus  

DOE Patents (OSTI)

An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

2011-03-22T23:59:59.000Z

180

Low Voltage White Phosphorescent OLED Achievements  

Energy.gov (U.S. Department of Energy (DOE))

Universal Display Corporation (UDC) and its research partners at Princeton University and the University of Southern California have succeeded in developing a white phosphorescent OLED (PHOLED™) that achieved a record efficiency of 20 lumens per watt. This achievement is the result of the team's collaborative efforts to increase the efficiency of PHOLED lighting by focusing on two critical factors: lowering the drive voltages and increasing the amount of light extracted.

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Classification of Voltage Sags Based on MPCA Models  

Science Journals Connector (OSTI)

In this paper, we introduce a new framework for classification of short duration voltage reductions in the area of Power Quality Monitoring using Multiway Principal Component Analysis (MPCA). Firstly, we recast the sags occurred in High Voltage (HV) ...

Abbas Khosravi; Joaquim Melendez; Joan Colomer

2007-06-01T23:59:59.000Z

182

A BIST Technique for RF Voltage-Controlled Oscillators  

Science Journals Connector (OSTI)

A built-in self-test (BIST) architecture is proposed for voltage-controlled oscillators (VCO) operating at multigigahertz frequencies. By utilizing a frequency divider and a frequency-to-voltage converter (FVC), the output frequency and tuning range ...

Hsieh-Hung Hsieh; Yen-Chih Huang; Liang-Hung Lu; Guo-Wei Huang

2007-10-01T23:59:59.000Z

183

Low voltage amplifier architecture for high speed switched capacitor circuits  

E-Print Network (OSTI)

This work concentrates on circuit realization of high speed and low voltage switched capacitor circuits, with emphasis on the operational transconductance amplifier (OTA). An overview of switched capacitor circuits is given. Speed and voltage...

Shankar, Asit

2012-06-07T23:59:59.000Z

184

Electro-optic voltage sensor head  

DOE Patents (OSTI)

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers.

Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Woods, Gregory K. (Cornelius, OR)

1999-01-01T23:59:59.000Z

185

Nickel-hydrogen voltage-efficiency model  

SciTech Connect

A model for providing voltage vs. current relationships and coulombic efficiency has been developed applicable to Nickel-Hydrogen (NiH{sub 2}) batteries. The performance relationships can be used directly in dynamic electrical energy storage system models or customized by predicting the particular case of voltage as a function of applied current. The algorithm utilizes electrochemical models for competing cell reactions: a single Butler-Volmer equation for the main NiH{sub 2} reaction, and a Tafel relationship for oxygen generation. For the main NiH{sub 2} reaction, the dependence on state-of-charge is introduced via a Nerstian term containing concentrations of active materials present. Oxygen recombination and self-discharge are modeled as first order reactions. Model parameters are determined by a modified Marquardt algorithm to provide a best-fit of both voltage and pressure data to the physical model. The data fit is from electrical characterization tests which may include capacity measurements or repeated electrical cycling at specified depths-of-discharge or with particular regimens. It has been found that test performance data covering a wide domain of the independent variables (temperature, current, and state-of-charge) will produce a well-behaved model.

Hafen, D.P.; Armantrout, J.D. [Lockheed Martin Missiles and Space, Sunnyvale, CA (United States)

1996-12-31T23:59:59.000Z

186

Analysis and design of an electronic voltage ratchet  

E-Print Network (OSTI)

and decay. Impulse voltages are produced through the discharging of 0, capacitor into a shaping network consisting of resistors and a. capacitor as is shown in Figure 2. 9. The operation of the impulse generator is as follows. Capacitor Ci is charged from... voltage shaping network. as possible in order to reduce oscillations in the wavefront and wavetail portions of the impulse voltage [1). The impulse voltage generator requires a, highly charged capacitor or bank of capacitors. Capacitors may be charged...

Menendez, Jorge Carlos

2012-06-07T23:59:59.000Z

187

LM2907LM2917FrequencytoVoltageConverter February 1995  

E-Print Network (OSTI)

TL H 7942 LM2907LM2917FrequencytoVoltageConverter February 1995 LM2907 LM2917 Frequency to Voltage Converter General Description The LM2907 LM2917 series are monolithic frequency to voltage converters doubling for low ripple full input protection in two versions (LM2907-8 LM2917-8) and its output swings

Wedeward, Kevin

188

Low voltage vertical recording preamplifier for hard disk drives  

E-Print Network (OSTI)

. . . . . . . . . . . . . . . . . 4 2 Input drivers of the preamplifier along with the decoupling caps and parasitics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3 Voltage bias voltage sensing scheme . . . . . . . . . . . . . . . . . . . 8 4 Current bias current... sensing scheme . . . . . . . . . . . . . . . . . . 9 5 Current bias scheme which common mode sense voltage to DE . . . . 10 6 Decoupling the inputs of the differential pair using feedback . . . . . 11 7 Barkhausen noise...

Mellachervu, Ramachandra Murthy

2004-11-15T23:59:59.000Z

189

The Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions  

E-Print Network (OSTI)

that generates variable magnitude variable frequency output voltage from the ac utility line. It has high power voltage disturbance related performance issues of the MC drive. Since the MC is a direct frequencyThe Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions Jun-Koo Kang

Hava, Ahmet

190

Variable current-voltage TPV device for use in a thermophotovoltaic energy conversion system  

DOE Patents (OSTI)

A front-side or back-side illuminated variable current-voltage thermophotovoltaic device comprises a support substrate; isolation layers disposed on the support substrate; a plurality of cells disposed on the isolation layers, each of the cells including a base layer and an emitter layer; an insulating member disposed between each of the cells configured to isolate each cell from adjacent cells; an ohmic contact configured to connect each cell to another cell in series; and a spectral control device disposed on top of the cells and/or on the bottom surface of the support substrate.

Charache, Greg W. (Clifton Park, NY); Baldasaro, Paul F. (Clifton Park, NY); Campbell, Brian C. (Scotia, NY)

2000-01-01T23:59:59.000Z

191

Iterative Bridge and Roll for Connection Rerouting  

Science Journals Connector (OSTI)

We propose a heuristic connection rerouting scheme that iteratively bridges and rolls a subset of connections for improving network utilization. The proposed scheme has no disrupted...

Zhang, Qiong; Gao, Chengyi; Wang, Xi; Palacharla, Paparao; Sekiya, Motoyoshi

192

GROWDERS Demonstration of Grid Connected Electricity Systems...  

Open Energy Info (EERE)

GROWDERS Demonstration of Grid Connected Electricity Systems (Smart Grid Project) (Spain) Jump to: navigation, search Project Name GROWDERS Demonstration of Grid Connected...

193

Study of Power Grid Connection with an Unstable Source from Elevator Energy Regenerative Unit (EERU)  

Science Journals Connector (OSTI)

Abstract This paper presents a study of power grid connection with an unstable source from elevator energy regenerative unit (EERU). The investigated system used a Permanent Magnet Synchronous Motor (PMSM). The EERU is installed for this system to generate electricity according to the generative mode of the elevator which delivers power to the grid as an unstable power source. To meet standard specifications in term of power quality and safety for grid connection, the phase angle and the amplitude as well as the frequency of the grid voltage are considered for grid connection. Phase lock loop (PLL) algorithm is therefore very important and selected for grid synchronization. The study is done by simulation using Matlab/Simulink program. The simulation used phase lock loop to synchronize between two systems. The results of this simulation will lead to a proper design of the grid connection with EERU as an unstable power source.

A. Noppakant; B. Plangklang; Y. Paraken

2014-01-01T23:59:59.000Z

194

Real Time Selective Harmonic Minimization for Multilevel Inverters Connected to Solar Panels Using Artificial Neural Network Angle Generation  

E-Print Network (OSTI)

Real Time Selective Harmonic Minimization for Multilevel Inverters Connected to Solar Panels Using varying DC input sources. Five 195 W solar panels were used as the DC source for each full bridge cells or solar panels and will consequently bring a voltage unbalance depending on the system dynamics

Tolbert, Leon M.

195

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided into high voltage  

E-Print Network (OSTI)

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided than one subtype of channel. A new subfamily of voltage-dependent calcium channel á1 subunit genes. 1999), having four domains, each with a voltage sensor and a pore-forming P loop. However

Dolphin, Annette C.

196

Enrichment of the Intracluster Medium  

E-Print Network (OSTI)

The relevance of galaxies of different luminosity and mass for the chemical enrichment of the intracluster medium (ICM) is analysed. For this purpose, I adopt the composite luminosity function of cluster galaxies from Trentham (1998), which exhibits a significant rise at the very faint end. The model - adopting a universal Salpeter IMF - is calibrated on reproducing the M_Fe/L_tot, M_Fe/M_*, and alpha/Fe ratios observed in clusters. Although the contribution to total luminosity and ICM metals peaks around L* galaxies (M* approx -20), faint objects with M_B>-18 still provide at least 30 per cent of the metals present in the ICM. In consistency with the solar alpha/Fe ratios determined by {ASCA}, the model predicts that 60 per cent of the ICM iron comes from Type Ia supernovae. The predicted slope of the relation between intracluster gas mass and cluster luminosity emerges shallower than the observed one, indicating that the fraction of primordial gas increases with cluster richness.

D. Thomas

1998-11-25T23:59:59.000Z

197

Low voltage ride-through of DFIG and brushless DFIG: Similarities and differences  

Science Journals Connector (OSTI)

Abstract The brushless doubly fed induction generator (BDFIG) has been proposed as a viable alternative in wind turbines to the commonly used doubly fed induction generator (DFIG). The BDFIG retains the benefits of the DFIG, i.e. variable speed operation with a partially rated converter, but without the use of brush gear and slip rings, thereby conferring enhanced reliability. As low voltage ride-through (LVRT) performance of the DFIG-based wind turbine is well understood, this paper aims to analyze LVRT behavior of the BDFIG-based wind turbine in a similar way. In order to achieve this goal, the equivalence between their two-axis model parameters is investigated. The variation of flux linkages, back-EMFs and currents of both types of generator are elaborated during three phase voltage dips. Moreover, the structural differences between the two generators, which lead to different equivalent parameters and hence different LVRT capabilities, are investigated. The analytical results are verified via time-domain simulations for medium size wind turbine generators as well as experimental results of a voltage dip on a prototype 250 kVA BDFIG.

S. Tohidi; P. Tavner; R. McMahon; H. Oraee; M.R. Zolghadri; S. Shao; E. Abdi

2014-01-01T23:59:59.000Z

198

Kirchhoff voltage law corrected for radiating circuits  

E-Print Network (OSTI)

When a circular loop composed by a RLC is put to oscillate, the oscillation will eventually vanish in an exponentially decaying current, even considering superconducting wires, due to the emission of electric and magnetic dipole radiation. In this work we propose a modification on the Kirchhoff voltage law by adding the radiative contributions to the energy loss as an effective resistance, whose value is relatively small when compared to typical resistance value, but fundamental to describe correctly real circuits. We have also analysed the change in the pattern of the radiation spectra emitted by the circuit as we vary both the effective and electrical resistance.

Lara, Vitor

2014-01-01T23:59:59.000Z

199

A High Voltage Direct Current Generator  

Science Journals Connector (OSTI)

When powdered materials are blown through metal tubes by means of compressed air considerable quantities of electricity are produced by contact electrification. It was found that 6×10-5 coulombs could be produced per gram of diatomaceous earth, a form of silica, blown through a short length of copper tube. A generator of extremely high voltage is proposed, and a small scale model of such a generator is described, by means of which currents of 8×10-5 amperes at 260 kilovolts were generated.

Richard E. Vollrath

1932-10-15T23:59:59.000Z

200

Connecting Again with Magnetic Reconnection  

Science Journals Connector (OSTI)

...Princeton, NJ 08543, USA. E-mail: wtang@pppl.gov Magnetic reconnection—the breaking...Princeton, NJ 08543, USA. E-mail: wtang@pppl.gov PLASMA PHYSICS: Connecting...Princeton, NJ 08543, USA. E-mail: wtang@pppl.gov

W. M. Tang

1998-03-06T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Asthma Triggers Connecting Your World  

E-Print Network (OSTI)

to plastics, cleaning chemicals, perfumed aerosols and other airborne volatile organic compounds (VOCs prototyped Asthma Triggers, a wireless sensor that scans the air for harmful chemicals and alerts users so with ZigBee wireless connectivity, builds on the ActuariusTM and the VitalSpanTM gateway cloud platform

Fisher, Kathleen

202

Connecting Remote Clusters with ATM  

SciTech Connect

Sandia's entry into utilizing clusters of networked workstations is called Computational Plant or CPlant for short. The design of CPlant uses Ethernet to boot the individual nodes, Myrinet to communicate within a node cluster, and ATM to connect between remote clusters. This SAND document covers the work done to enable the use of ATM on the CPlant nodes in the Fall of 1997.

Hu, T.C.; Wyckoff, P.S.

1998-10-01T23:59:59.000Z

203

Safe epoxy encapsulant for high voltage magnetics  

SciTech Connect

This paper describes the use of Formula 456, an aliphatic amine cured epoxy for impregnating coils and high voltage transformers. Sandia has evaluated a number of MDA-free epoxy encapsulants which relied on either anhydride or other aromatic amine curing agents. The use of aliphatic amine curing agents was more recently evaluated and has resulted in the definition of Formula 456 resin. Methylene dianiline (MDA) has been used for more than 20 years as the curing agent for various epoxy formulations throughout the Department of Energy and much of industry. Sandia National Laboratories began the process of replacing MDA with other formulations because of regulations imposed by OSHA on the use of MDA. OSHA has regulated MDA because it is a suspect carcinogen. Typically the elimination of OSHA-regulated materials provides a rare opportunity to qualify new formulations in a range of demanding applications. It was important to take full advantage of that opportunity, although the associated materials qualification effort was costly. Small high voltage transformers are one of those demanding applications. The successful implementation of the new formulation for high reliability transformers will be described. The test results that demonstrate the parts are qualified for use in DOE weapon systems will be presented.

Sanchez, R.O.; Archer, W.E.

1998-01-01T23:59:59.000Z

204

Accelerator System Development at High Voltage Engineering  

SciTech Connect

Throughout the years, HVE has continuously extended the capabilities of its accelerator systems to meet the rising demands from a diverse field of applications, among which are deep level ion implantation, micro-machining, neutron production for biomedical research, isotope production or accelerator mass spectrometry. Characteristic for HVE accelerators is the coaxial construction of the all solid state power supply around the acceleration tubes. With the use of solid state technology, the accelerators feature high stability and very low ripple. Terminal voltages range from 1 to 6 MV for HVE Singletrons and Tandetrons. The high-current versions of these accelerators can provide ion beams with powers of several kW. In the last years, several systems have been built with terminal voltages of 1.25 MV, 2 MV and 5 MV. Recently, the first system based on a 6 MV Tandetron has passed the factory tests. In this paper we describe the characteristics of the HVE accelerator systems and present as example recent systems.

Klein, M. G.; Gottdang, A.; Haitsma, R. G.; Mous, D. J. W. [High Voltage Engineering Europa B.V., P.O. Box 99, Amersfoort 3800 AB (Netherlands)

2009-03-10T23:59:59.000Z

205

Low voltage operation of plasma focus  

Science Journals Connector (OSTI)

Plasma foci of compact sizes and operating with low energies (from tens of joules to few hundred joules) have found application in recent years and have attracted plasma-physics scientists and engineers for research in this direction. We are presenting a low energy and miniature plasma focus which operates from a capacitor bank of 8.4 ? ? F capacity charged at 4.2–4.3 kV and delivering approximately 52 kA peak current at approximately 60 nH calculated circuit inductance. The total circuit inductance includes the plasma focusinductance. The reported plasma focus operates at the lowest voltage among all reported plasma foci so far. Moreover the cost of capacitor bank used for plasma focus is nearly 20 U.S. dollars making it very cheap. At low voltage operation of plasma focus the initial breakdown mechanism becomes important for operation of plasma focus. The quartz glass tube is used as insulator and breakdown initiation is done on its surface. The total energy of the plasma focus is approximately 75 J. The plasma focus system is made compact and the switching of capacitor bank energy is done by manual operating switch. The focus is operated with hydrogen and deuterium filled at 1–2 mbar.

Rohit Shukla; S. K. Sharma; P. Banerjee; R. Das; P. Deb; T. Prabahar; B. K. Das; B. Adhikary; A. Shyam

2010-01-01T23:59:59.000Z

206

A renewed look at eta' in medium  

E-Print Network (OSTI)

We revisit the question of whether the U_A(1) symmetry is effectively restored in hot and dense medium. In particular, by generalizing the Witten-Veneziano formula to finite temperature, we investigate whether the mass of eta'-meson will change in medium due to the restoration of chiral symmetry.

Youngshin Kwon; Su Houng Lee; Kenji Morita; Gyuri Wolf

2012-04-14T23:59:59.000Z

207

Chiral Restoration in a Nuclear Medium  

Science Journals Connector (OSTI)

......nuclei and nuclear collisions. At the future Accelerator Facility...Structure of the Vacuum and Elementary...GSI future accelerator facility...antiprotons In a nuclear medium the...function for the vacuum production...mesons in a nuclear medium. With the accelerator facility...Structure of the Vacuum and Elementary......

Paul Kienle

2003-01-01T23:59:59.000Z

208

Current-based direct power control of a DFIG under unbalanced grid voltage  

Science Journals Connector (OSTI)

Abstract A novel current-based direct power control (CB-DPC) strategy for a grid-connected doubly-fed induction generator (DFIG) is proposed. The reported control scheme is applicable to DFIG-based variable-speed wind turbines that operate under unbalanced network voltages. The required DFIG rotor voltage for precise regulation of the stator active and reactive output powers and accurate elimination of their inherent pulsations are directly obtained using a nonlinear integral sliding-mode control (ISMC) scheme. Compared with other control methods, the proposed strategy is simpler since it is not based on the symmetrical components theory, does not need multiple synchronous coordinate transformations, and only requires DFIG voltage and current values as its inputs. Constant switching frequency of the rotor-side converter (RSC) is achieved by means of space vector pulse-width modulation (SVPWM) technique. Uncertainties in the parameters of the generator are included in the design. A compensation strategy is also proposed for tracking error mitigation of the powers that occur due to elimination of the chattering phenomena in the ISMC scheme. Simulation results on a 2MW DFIG under different operating conditions are presented to validate the effectiveness and robustness of the proposed method.

Mohammad Farshadnia; Seyed Abbas Taher

2014-01-01T23:59:59.000Z

209

Dynamics of filament formation in a Kerr medium  

SciTech Connect

We have studied the large-scale beam breakup and filamentation of femtosecond pulses in a Kerr medium. We have experimentally monitored the formation of stable light filaments, conical emission, and interactions between filaments. Three major stages lead to the formation of stable light filaments: First the beam breaks up into a pattern of connected lines (constellation), then filaments form on the constellations, and finally the filaments release a fraction of their energy through conical emission. We observed a phase transition to a faster filamentation rate at the onset of conical emission. We attribute this to the interaction of conical emissions with the constellation which creates additional filaments. Numerical simulations show good agreement with the experimental results.

Centurion, Martin [Physics Department, California Institute of Technology, Pasadena, California 91125 (United States); Pu Ye; Tsang, Mankei; Psaltis, Demetri [Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125 (United States)

2005-06-15T23:59:59.000Z

210

Dynamics of filament formation in a Kerr medium  

Science Journals Connector (OSTI)

We have studied the large-scale beam breakup and filamentation of femtosecond pulses in a Kerr medium. We have experimentally monitored the formation of stable light filaments, conical emission, and interactions between filaments. Three major stages lead to the formation of stable light filaments: First the beam breaks up into a pattern of connected lines (constellation), then filaments form on the constellations, and finally the filaments release a fraction of their energy through conical emission. We observed a phase transition to a faster filamentation rate at the onset of conical emission. We attribute this to the interaction of conical emissions with the constellation which creates additional filaments. Numerical simulations show good agreement with the experimental results.

Martin Centurion; Ye Pu; Mankei Tsang; Demetri Psaltis

2005-06-17T23:59:59.000Z

211

Induction generator voltage improvement using a new control strategy for turbo-expander driving systems  

Science Journals Connector (OSTI)

Abstract Turbo-expanders are relatively new sources of dispersed generation which are used to drive the electrical generators. The conventional pressure regulating valves are replaced by these devices in the gas pressure reduction station. Connecting the dispersed generation to the distribution networks especially for squirrel cage induction generators, may result in some power quality problems. These problems can be obviated using special devices in electrical networks or modifying the control system of the prime mover system in mechanical parts. In this paper, it is focused on the Point of Common Coupling (PCC) voltage where a turbo-expander driven induction generator is connected. A new control strategy based on fuzzy controlled PID is considered for the mechanical part of the turbo-expander nozzle system. The results show a better control of turbo-expander output power in a linear form over the full range of operating points. The other purpose of the control system modification is to improve the power quality and stabilize the PCC voltage in different operating point conditions.

Mehdi Taleshian Jelodar; Hasan Rastegar; Mohammad Pichan

2015-01-01T23:59:59.000Z

212

Modeling and Grid impedance Variation Analysis of Parallel Connected Grid Connected Inverter  

E-Print Network (OSTI)

Modeling and Grid impedance Variation Analysis of Parallel Connected Grid Connected Inverter based - This paper addresses the harmonic compensation error problem existing with parallel connected inverter grid connected inverter, it is found that multiple parallel connected inverters and grid impedance can

Bak, Claus Leth

213

Design and applications of a flicker voltage generator  

SciTech Connect

In this paper, a 200W flicker voltage generator is made by using microcomputers and linear amplification circuits. The modulation amplitudes and frequencies based on the UIE {Delta}V{sub 10} evaluation can be arbitrarily assigned by software with high accuracy. The flicker voltage signals measured at the customer side also can be re-generated. Some applications, such as evaluating the effects of flicker voltage on incandescent and compact fluorescent lamps (CFLs), are also made. From experimental tests by use of the flicker voltage generator, the properties of some compact fluorescent lamps and incandescent lamps are compared. Those properties describe the relation between input voltage variation and output flux of lamps, such that there is direct description of influences of flicker voltages on lamps.

Chang, W.N.; Wu, C.J. [National Taiwan Inst. of Tech., Peitow-Taipei (Taiwan, Province of China). Dept. of Electrical Engineering

1995-12-31T23:59:59.000Z

214

Peculiarities of the current-voltage characteristics of a Josephson medium in a YBCO high-temperature superconductor  

Science Journals Connector (OSTI)

The influence of a weak magnetic field (H high-temperature superconductor (HTSC) near the superconducting transitio...

M. A. Vasyutin

2013-12-01T23:59:59.000Z

215

Method to prepare nanoparticles on porous mediums  

DOE Patents (OSTI)

A method to prepare porous medium decorated with nanoparticles involves contacting a suspension of nanoparticles in an ionic liquid with a porous medium such that the particles diffuse into the pores of the medium followed by heating the resulting composition to a temperature equal to or greater than the thermal decomposition temperature of the ionic liquid resulting in the removal of the liquid portion of the suspension. The nanoparticles can be a metal, an alloy, or a metal compound. The resulting compositions can be used as catalysts, sensors, or separators.

Vieth, Gabriel M. (Knoxville, TN) [Knoxville, TN; Dudney, Nancy J. (Oak Ridge, TN) [Oak Ridge, TN; Dai, Sheng (Knoxville, TN) [Knoxville, TN

2010-08-10T23:59:59.000Z

216

Voltage stabilization system in traction substation of urban electric transport  

Science Journals Connector (OSTI)

The direct current-voltage stabilization system using a high-frequency link in traction substations of urban electric transport based on applying...

S. V. Shapiro; S. F. Muftiev

2011-02-01T23:59:59.000Z

217

High Temperature, High Voltage Fully Integrated Gate Driver Circuit  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

driver circuit, 5-V on- chip voltage regulator, short-circuit protection, undervoltage lockout, bootstrap capacitor, dead time controller and temperature sensor * 0.8-micron,...

218

Triple voltage dc-to-dc converter and method  

DOE Patents (OSTI)

A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

Su, Gui-Jia (Knoxville, TN)

2008-08-05T23:59:59.000Z

219

fault diagnosis of a high voltage transmission line using waveform ...  

E-Print Network (OSTI)

Oct 4, 2013 ... FAULT DIAGNOSIS OF A HIGH VOLTAGE TRANSMISSION LINE USING ... Fault types such as single line to ground, line to line, double line to ...

Ripunjoy Phukan

2013-10-04T23:59:59.000Z

220

Low voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips  

Science Journals Connector (OSTI)

Abstract This paper proposes a competent and effective scheme to enhance the ride-through capability of DFIG-based wind turbines under unbalanced voltage dip conditions. The proposed method is realized through joint use of the rotor-side converter control and a three-phase stator damping resistor (SDR) placed in series with the stator windings. By means of an asymmetrical SDR idea, during the unbalanced voltage dip the SDR resistors are activated only in phase(s) experiencing low voltage. Then, the rotor current is controlled such that no unbalance voltage appears on the stator voltage. The proposed ride-through approach limits the peak values of the rotor inrush current, electromagnetic torque and DFIG transient response at the times of occurrence and clearing the fault. It also suppresses fluctuation of the electromagnetic torque and DFIG transient response appeared during unbalanced voltage dips due to negative sequence component.

Mohsen Rahimi; Mostafa Parniani

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

A MODEL FOR POROUS-MEDIUM COMBUSTION  

Science Journals Connector (OSTI)

......these applied in coal combustion appears in...understanding of the chemistry of combustion...GLASSMAN, Combustion (Academic Press...ESSENHIGH, In Chemistry of Coal Utilization...POROUS-MEDIUM COMBUSTION 177 8. D. A......

J. NORBURY; A. M. STUART

1989-02-01T23:59:59.000Z

222

Cognitive Medium Access: Exploration, Exploitation and Competition  

E-Print Network (OSTI)

1 Cognitive Medium Access: Exploration, Exploitation and Competition Lifeng Lai, Hesham El Gamal, Hai Jiang and H. Vincent Poor Abstract-- This paper establishes the equivalence between cognitive cognitive user wishes to opportunistically exploit the availability of empty fre- quency bands

El-Gamal, Hesham

223

SciTech Connect: auroras  

Office of Scientific and Technical Information (OSTI)

auroras Find auroras Find How should I search Scitech Connect ... Basic or Advanced? Basic Search Advanced Ă— Advanced Search Options Full Text: Bibliographic Data: Creator / Author: Name Name ORCID Title: Subject: Identifier Numbers: Research Org.: Sponsoring Org.: Site: All Alaska Power Administration, Juneau, Alaska (United States) Albany Research Center (ARC), Albany, OR (United States) Albuquerque Complex - NNSA Albuquerque Operations Office, Albuquerque, NM (United States) Amarillo National Resource Center for Plutonium, Amarillo, TX (United States) Ames Laboratory (AMES), Ames, IA (United States) Argonne National Laboratory (ANL), Argonne, IL (United States) Argonne National Laboratory-Advanced Photon Source (United States) Atlanta Regional Office, Atlanta, GA (United States) Atmospheric Radiation Measurement (ARM)

224

SciTech Connect: higgs  

Office of Scientific and Technical Information (OSTI)

higgs Find higgs Find How should I search Scitech Connect ... Basic or Advanced? Basic Search Advanced Ă— Advanced Search Options Full Text: Bibliographic Data: Creator / Author: Name Name ORCID Title: Subject: Identifier Numbers: Research Org.: Sponsoring Org.: Site: All Alaska Power Administration, Juneau, Alaska (United States) Albany Research Center (ARC), Albany, OR (United States) Albuquerque Complex - NNSA Albuquerque Operations Office, Albuquerque, NM (United States) Amarillo National Resource Center for Plutonium, Amarillo, TX (United States) Ames Laboratory (AMES), Ames, IA (United States) Argonne National Laboratory (ANL), Argonne, IL (United States) Argonne National Laboratory-Advanced Photon Source (United States) Atlanta Regional Office, Atlanta, GA (United States) Atmospheric Radiation Measurement (ARM)

225

SciTech Connect: plasma  

Office of Scientific and Technical Information (OSTI)

plasma Find plasma Find How should I search Scitech Connect ... Basic or Advanced? Basic Search Advanced Ă— Advanced Search Options Full Text: Bibliographic Data: Creator / Author: Name Name ORCID Title: Subject: Identifier Numbers: Research Org.: Sponsoring Org.: Site: All Alaska Power Administration, Juneau, Alaska (United States) Albany Research Center (ARC), Albany, OR (United States) Albuquerque Complex - NNSA Albuquerque Operations Office, Albuquerque, NM (United States) Amarillo National Resource Center for Plutonium, Amarillo, TX (United States) Ames Laboratory (AMES), Ames, IA (United States) Argonne National Laboratory (ANL), Argonne, IL (United States) Argonne National Laboratory-Advanced Photon Source (United States) Atlanta Regional Office, Atlanta, GA (United States) Atmospheric Radiation Measurement (ARM)

226

Inferring network connectivity using kinetic Ising models  

Science Journals Connector (OSTI)

One approach that has been explored recently for analyzing functional connectivity involves parametrizing the spike pattern distribution by an Ising model with symmetric connectivity. However, the...1...]. Here w...

John A Hertz; Yasser Roudi; Andreas Thorning; Joanna Tyrcha…

2010-07-01T23:59:59.000Z

227

Monolithically interconnected GaAs solar cells: A new interconnection technology for high voltage solar cell output  

SciTech Connect

Photovoltaic linear concentrator arrays can benefit from high performance solar cell technologies being developed at AstroPower. Specifically, these are the integration of thin GaAs solar cell and epitaxial lateral overgrowth technologies with the application of monolithically interconnected solar cell (MISC) techniques. This MISC array has several advantages which make it ideal for space concentrator systems. These are high system voltage, reliable low cost monolithically formed interconnections, design flexibility, costs that are independent of array voltage, and low power loss from shorts, opens, and impact damage. This concentrator solar cell will incorporate the benefits of light trapping by growing the device active layers over a low-cost, simple, PECVD deposited silicon/silicon dioxide Bragg reflector. The high voltage-low current output results in minimal 12R losses while properly designing the device allows for minimal shading and resistance losses. It is possible to obtain open circuit voltages as high as 67 volts/cm of solar cell length with existing technology. The projected power density for the high performance device is 5 kW/m for an AMO efficiency of 26% at 1 5X. Concentrator solar cell arrays are necessary to meet the power requirements of specific mission platforms and can supply high voltage power for electric propulsion systems. It is anticipated that the high efficiency, GaAs monolithically interconnected linear concentrator solar cell array will enjoy widespread application for space based solar power needs. Additional applications include remote man-portable or ultra-light unmanned air vehicle (UAV) power supplies where high power per area, high radiation hardness and a high bus voltage or low bus current are important. The monolithic approach has a number of inherent advantages, including reduced cost per interconnect and increased reliability of array connections. There is also a high potential for a large number of consumer products.

Dinetta, L.C.; Hannon, M.H.

1995-10-01T23:59:59.000Z

228

EUROMED SUSTAINABLE CONNECTIONS ANNA LINDH FOUNDATION  

E-Print Network (OSTI)

EUROMED SUSTAINABLE CONNECTIONS ANNA LINDH FOUNDATION No ALF/2007/CFP2/F/54 May, 2008 Establishing Sustainable Community Development Connections in the Mediterranean Region Case Study Project Report Nicholas C. Stavrakis9 , D. Wojciech10 , and Cynthia Zaferatos11 1.0 Introduction The Sustainable Community Connections

Zaferatos, Nicholas C.

229

Simplified VO M&V Protocol Simplified Voltage Optimization (VO)  

E-Print Network (OSTI)

Simplified VO M&V Protocol 1 Simplified Voltage Optimization (VO) Measurement and Verification Protocol 1.0 Introduction 1.1 Purpose The Simplified Voltage Optimization (VO) Measurement and Verification requirements, and measurement and verification formulations are included as part of this Protocol. 1

230

Task Scheduling and Voltage Selection for Energy Minimization  

E-Print Network (OSTI)

system con gurations. 1. INTRODUCTION Energy consumption has become a primary concern in today's ICTask Scheduling and Voltage Selection for Energy Minimization Yumin Zhang Synopsys, Inc. 700 East-phase framework that inte- grates task assignment, ordering and voltage selection VS together to minimize energy

Hu, Xiaobo Sharon

231

IMPACT OF DYNAMIC VOLTAGE SCALING (DVS) ON CIRCUIT OPTIMIZATION  

E-Print Network (OSTI)

and dynamic power, respectively. Both gate sizing and Dual-VT are design-time techniques, which are applied to the circuit at a fixed voltage. On the other hand, DVS is a run-time technique and implies that the circuit will be operating at a different voltage...

Esquit Hernandez, Carlos A.

2010-01-16T23:59:59.000Z

232

REFINED RFP LOOP VOLTAGE CALCULATION J.C. Sprott  

E-Print Network (OSTI)

is the stored magnetic energy, Up is the plasma energy, and 'E is the global energy confinement time, which-of-merit for RFP devices is the loop voltage. Low loop voltage implies high plasma temperature and long energy is smallest if the loop is as close to the outside of the shell and as far from the primary windings

Sprott, Julien Clinton

233

LOW VOLTAGE ANALOG CIRCUITS USING STANDARD CMOS TECHNOLOGY  

E-Print Network (OSTI)

LOW VOLTAGE ANALOG CIRCUITS USING STANDARD CMOS TECHNOLOGY Phillip E. Allen, Benjamin J. Blalock, and Gabriel A. Rincon School of Electrical and Computer Engineering Georgia Institute of Technology Atlanta supply voltages in CMOS integrated circuits. As the channel lengths of CMOS technology decrease

Rincon-Mora, Gabriel A.

234

Measurement of high voltage using Rutherford backscattering spectrometry  

E-Print Network (OSTI)

A novel variation of Rutherford Backscattering Spectrometry (RBS) has been utilized to measure a high voltage collected on an aluminum target by Direct Energy Conversion. The maximum high voltage on the target was measured to be 97.5 kV +/- 2 kV...

Abrego, Celestino Pete

2007-04-25T23:59:59.000Z

235

Nonlinear voltages in multiple-lead coherent conductors  

Science Journals Connector (OSTI)

We use the generalized S-matrix approach to study multiple-lead coherent conductors in the case of finite applied voltages. In this framework we discuss the transverse voltage arising in a four-lead conductor with two symmetric biased leads.

Gordey B. Lesovik and Carlo Presilla

1993-01-15T23:59:59.000Z

236

The Cavendish high-voltage laboratory 1935–39  

Science Journals Connector (OSTI)

...the period covered. Nuclear Transmutation|Cavendish...development of high-voltage nuclear transmutation equipment...experimental work in nuclear physics though he continued...a new high-voltage accelerator therefore fell mainly...doubler circuit with six vacuum rectifiers forming a...

1999-01-01T23:59:59.000Z

237

Spark-safe low-voltage detonator  

DOE Patents (OSTI)

A column of explosive in a low-voltage detonator which makes it spark-safe ncludes an organic secondary explosive charge of HMX in the form of a thin pad disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to an electrical ignition device at one end of the bore. The pad of secondary charge has an axial thickness within the range of twenty to thirty percent of its diameter. The explosive column also includes a first explosive charge of CP disposed in the housing bore in the ignition region of the explosive column next to the secondary charge pad on a side opposite from the ignition device. The first CP charge is loaded under sufficient pressure, 25 to 40 kpsi, to provide mechanical confinement of the pad of secondary charge and physical coupling thereof with the ignition device. The explosive column further includes a second explosive charge of CP disposed in the housing bore in a transition region of the explosive column next to the first CP charge on a side opposite from the pad of secondary charge. The second CP charge is loaded under sufficient pressure, about 10 kpsi, to allow occurrence of DDT. The first explosive CP charge has an axial thickness within the range of twenty to thirty percent of its diameter, whereas the second explosive CP charge contains a series of increments (nominally 4) each of which has an axial thickness-to-diameter ratio of one to two.

Lieberman, Morton L. (Albuquerque, NM)

1989-01-01T23:59:59.000Z

238

Bonfire-safe low-voltage detonator  

DOE Patents (OSTI)

A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half.

Lieberman, Morton L. (Albuquerque, NM)

1990-01-01T23:59:59.000Z

239

Boosting the voltage of a salinity-gradient-power electrochemical cell by means of complex-forming solutions  

Science Journals Connector (OSTI)

We report experiments on a concentration cell with zinc electrodes and ZnCl2 solutions at different concentrations separated by a porous diaphragm. The cell is aimed at the conversion of the free energy associated to the concentration difference into electrical energy for renewable and clean energy applications. Usually the diffusion of the solute across the diaphragm constitutes a waste of free energy which impairs the voltage generation of the concentration cell with respect to other well-known techniques that work quasi-reversibly such as reverse electrodialysis or the “mixing entropy battery.” Quite surprisingly we find that the voltage produced by our concentration cell is significantly higher than the voltage obtained with the other quasi-reversible techniques. We show that the surplus voltage comes from the active transformation of the mixing free energy into electrical energy performed by the liquid junction and we show the connection with the negative apparent transference number of the zinc ion. This fortunate consequence of using ZnCl2 solution is ultimately related to the formation of complexes. We present the results of a cell for power production which has excellent performances with respect to known salinity-difference-power methods.

2014-01-01T23:59:59.000Z

240

Definition: Automated Voltage And Var Control | Open Energy Information  

Open Energy Info (EERE)

Voltage And Var Control Voltage And Var Control Jump to: navigation, search Dictionary.png Automated Voltage And Var Control Automated voltage and VAR control requires coordinated operation of reactive power resources such as capacitor banks, voltage regulators, transformer load-tap changers, and distributed generation (DG) with sensors, controls, and communications systems. These devices could operate autonomously in response to local events or in response to signals from a central control system.[1] View on Wikipedia Wikipedia Definition Also Known As Volt-VAR Control (VVC) Related Terms smart grid, Reactive Power References ↑ SmartGrid.gov 'Description of Functions' An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Living and Working Safely Around High-Voltage Power Lines.  

SciTech Connect

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

United States. Bonneville Power Administration.

2001-06-01T23:59:59.000Z

242

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1996-01-01T23:59:59.000Z

243

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

Shimer, D.W.; Lange, A.C.

1996-10-15T23:59:59.000Z

244

ON THE PROPAGATION OF ENERGY IN A STRATIFIED GASEOUS MEDIUM  

Science Journals Connector (OSTI)

...MEDIUM Steven Rosencrans MASSACHUSETTS INSTITUTE OF TECHNOLOGY ON...STRATIFIED GASEOUS MEDIUM. | MASSACHUSETTS INSTITUTE OF TECHNOLOGY...MEDIUM* BY STEVEN ROSENCRANS MASSACHUSETTS INSTITUTE OF TECHNOLOGY Communicated...responsible for the heating of the solar corona.6 (The top of our...

Steven Rosencrans

1965-01-01T23:59:59.000Z

245

TE Connectivity Finds Answers in Tomography  

NLE Websites -- All DOE Office Websites (Extended Search)

TE Connectivity Finds Answers in TE Connectivity Finds Answers in Tomography TE Connectivity Finds Answers in Tomography Print Thursday, 22 August 2013 10:50 TE Connectivity is a world leader in connectivity-the $13 billion global company designs and manufactures more than 500,000 different electronic connectivity products for the automotive, energy, industrial, broadband communications, consumer device, healthcare, aerospace, and defense industries. TE Connectivity has a long-standing commitment to innovation and engineering excellence. Their products help address challenges arising from companies' need for energy efficiency, always-on communications, and ever-increasing productivity. Recently, a team led by TE's senior manager of materials development, Dr. Jerzy Gazda (at left), has been investigating how ALS tomography capabilities can help the company develop more efficient connectors.

246

LNT + SCR Aftertreatment for Medium-Heavy Duty Applications:...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

+ SCR Aftertreatment for Medium-Heavy Duty Applications: A Systems Approach LNT + SCR Aftertreatment for Medium-Heavy Duty Applications: A Systems Approach Poster presentation at...

247

Small- and Medium-Size Building Automation and Control System...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Emerging...

248

Removal of Carbon Tetrachloride from a Layered Porous Medium...  

NLE Websites -- All DOE Office Websites (Extended Search)

Carbon Tetrachloride from a Layered Porous Medium by Means of Soil Vapor Extraction Enhanced by Desiccation and Water Removal of Carbon Tetrachloride from a Layered Porous Medium...

249

Removal of carbon tetrachloride from a layered porous medium...  

NLE Websites -- All DOE Office Websites (Extended Search)

carbon tetrachloride from a layered porous medium by means of soil vapor extraction enhanced by desiccation and water Removal of carbon tetrachloride from a layered porous medium...

250

High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

Shimer, D.W.; Lange, A.C.

1995-05-23T23:59:59.000Z

251

High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1995-01-01T23:59:59.000Z

252

Category:MediumOffice | Open Energy Information  

Open Energy Info (EERE)

MediumOffice MediumOffice Jump to: navigation, search Go Back to PV Economics By Building Type Media in category "MediumOffice" The following 77 files are in this category, out of 77 total. SVMediumOffice Bismarck ND Montana-Dakota Utilities Co (North Dakota).png SVMediumOffice Bismarc... 72 KB SVMediumOffice Cedar City UT Moon Lake Electric Assn Inc (Utah).png SVMediumOffice Cedar C... 62 KB SVMediumOffice International Falls MN Northern States Power Co (Minnesota) Excel Energy.png SVMediumOffice Interna... 83 KB SVMediumOffice LA CA City of Los Angeles California (Utility Company).png SVMediumOffice LA CA C... 87 KB SVMediumOffice Memphis TN City of Memphis Tennessee (Utility Company).png SVMediumOffice Memphis... 65 KB SVMediumOffice Minneapolis MN Northern States Power Co (Minnesota) Excel Energy.png

253

Electro-optic voltage sensor with Multiple Beam Splitting  

DOE Patents (OSTI)

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID)

2000-01-01T23:59:59.000Z

254

Electro-optic voltage sensor with beam splitting  

DOE Patents (OSTI)

The invention is a miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware typically found in the prior art. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

255

Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis  

E-Print Network (OSTI)

Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis Claudio A. Ca|Thispaper describesseveralapplica- tions of optimization for voltage stability analysis VSA of power systems. Voltage stability prob

Cañizares, Claudio A.

256

In-Medium Properties of Hadrons  

E-Print Network (OSTI)

A diverse experimental program for the study of the photoproduction of mesons off nuclei has been carried out - and is still running - at the Mainz MAMI and Bonn ELSA electron accelerators with the TAPS, Crystal Barrel, and Crystal Ball calorimeters. It is motivated as a detailed study of the in-medium properties of hadrons and the meson - nucleus interactions. Typical examples for the in-medium behavior of vector mesons ($\\omega$), scalar mesons ($\\sigma$), and nucleon resonances (P$_{33}$(1232), S$_{11}$(1535), D$_{15}$(1520)) are discussed. Special attention is paid to meson - nucleus final state interactions.

B. Krusche

2006-08-24T23:59:59.000Z

257

High-voltage supply for backward-wave tube  

SciTech Connect

A high-current high-voltage supply for a backward-wave tube is described that uses a generalppurpose semiconductor converter with pulse-width modulation and two-stage regulation. The load current is up to 250 mA for load voltages of from 0.5 to 4.5 kV. The voltage staiblity is less than or equal to 5 x 10/sup -6/. the root-mean-square output ripple is less than or equal to 2 x 10/sup -6// The supply is equipped with high-speed (5 usec) load-breakdown protection.

Bryvkhanov, A.N.; Kosarev, P.M.; Latushkin, S.T.; Yudin, L.I.

1986-04-01T23:59:59.000Z

258

Harmonic and interharmonic distortion analysis in the grid-connected wind electric generator  

Science Journals Connector (OSTI)

The operation of wind turbines has an impact on the power quality at the connected electric network. The integration of wind electric generators with the power grid becomes a headache for power engineers in several aspects. Harmonic distortion is one of the most important phenomena which affect the grid performance. This paper provides an in-depth discussion on harmonic and interharmonic distortion taking place on the low-voltage side of the wind generator, as well as in the power grid side. A case study, to determine where a significant amount of harmonic currents or voltages exists in the system, is performed using a power quality analyser. From these measurements and subsequent calculations, the levels of harmonics and interharmonics are analysed. It is found that the harmonic distortion is invariably present on the generator side as well as on the grid side, depending on the wind turbine technology.

V. Suresh Kumar; P.S. Kannan

2007-01-01T23:59:59.000Z

259

A straightforward method to extract the shunt resistance of photovoltaic cells from current–voltage characteristics of mounted arrays  

Science Journals Connector (OSTI)

A straightforward non-invasive method is proposed to accurately evaluate the shunt resistance of an elementary cell of a photovoltaic module connected in an installed string without requiring prior knowledge of the parameters of the intrinsic diodes. The approach relies on the measurement of the current–voltage characteristic of the whole string after intentionally shading the selected cell. Calibrated PSPICE simulations are employed to illustrate the method and test its reliability. As a case study, the shunt resistances of several cells belonging to a series array of 10 commercial panels are determined.

Vincenzo d’Alessandro; Pierluigi Guerriero; Santolo Daliento; Matteo Gargiulo

2011-01-01T23:59:59.000Z

260

A PC-PCL-based control system for the high-voltage pulsed-power operation of the Intense Diagnostic Neutral Beam (IDNB) Experiment  

SciTech Connect

A stand-alone, semiautomated control system for the high-voltage pulsed-power energy sources on the Intense Diagnostic Neutral Beam Experiment at Los Alamos National Laboratory using personal computer (PC) and programmable logic controller (PLC) technology has been developed and implemented. The control system, consisting of a PC with the graphic operator interface, the network connecting the PC to the PLC, the PLC, the PLC I/O modules, fiber-optic interfaces and software, is described.

Gribble, R.

1993-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Optically Transparent, Electrically Conductive Composite Medium  

Science Journals Connector (OSTI)

...found below and above these two lower shale beds. Although it is possible that reworking...by the three shocked quartz-bearing shales, but there are at least 250 m of Norian...of the transparent composite medium. anisotropic. The transparency along the ver-tical...

S. JIN; T. H. TIEFEL; R. WOLFE; R. C. SHERWOOD; J. J. MOTTINE JR.

1992-01-24T23:59:59.000Z

262

In-Medium Modifications of Hadron Properties  

E-Print Network (OSTI)

The in-medium modifications of hadron properties are briefly discussed. We restrict the discussion to the lattice QCD calculations for the hadron masses, screening masses, decay constants and wave functions. We review the progress made so far and describe how to broaden its horizon.

A. Tawfik

2006-03-22T23:59:59.000Z

263

California Member Connects Solar Adoption With Upgrades  

Energy.gov (U.S. Department of Energy (DOE))

Studies on the connection between solar adoption and energy upgrades by Better Buildings Residential Network member Center for Sustainable Energy (CSE) in California are helping solar companies...

264

High-voltage air-core pulse transformers  

SciTech Connect

General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

Rohwein, G. J.

1981-01-01T23:59:59.000Z

265

Optical crystal based devices for current and voltage measurement  

SciTech Connect

A prerequisite for safe, stable operation of an electric power system is accurate, reliable measurement of the system parameters, in particular, current and voltage. Traditionally this has been achieved on High Voltage (HV) systems by expensive, bulky iron-cored current transformers (CTs) and capacitor voltage transformers (VTs). Both these devices are increasingly coming under review in modern power systems due to their cost, safety implications for personnel and surrounding plant if failure occurs, installation time and indeed substation land requirements. This paper describes novel designs for magneto-optic and electro-optic crystal sensors providing potentially separate and combined current and voltage measurement. The results of testing programs are presented and details of the work associated with field trials given.

Cruden, A.; Richardson, Z.J.; McDonald, J.R.; Andonovic, I. [Univ. of Strathclyde (United Kingdom)] [Univ. of Strathclyde (United Kingdom)

1995-07-01T23:59:59.000Z

266

Design & Fabrication of a High-Voltage Photovoltaic Cell  

SciTech Connect

Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

Felder, Jennifer; /North Carolina State U. /SLAC

2012-09-05T23:59:59.000Z

267

High Voltage Electrolytes for Li-ion Batteries | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electrolytes for Li-ion Batteries High Voltage Electrolytes for Li-ion Batteries 2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and...

268

Long term voltage stability analysis for small disturbances  

E-Print Network (OSTI)

This dissertation attempts to establish an analytical and comprehensive framework to deal with two critical challenges associated with voltage stability analysis: 1. To study the new competitive environment appropriately and give more incentive...

Men, Kun

2009-05-15T23:59:59.000Z

269

Voltage asymmetry at the buses of a combined substation  

Science Journals Connector (OSTI)

The voltage asymmetry at the buses of a combined (ac/dc) substation is calculated by phase method, using Mathcad ... , power may be supplied to a combined substation along a common line from a limited-...

A. G. Pakulin; V. A. Zagorskii; V. F. Put’ko

2013-07-01T23:59:59.000Z

270

Operation of buck regulator with ultra-low input voltage  

E-Print Network (OSTI)

Based on the LTC3621 and LTC3624, the designed buck regulator proposed in this thesis aims to lower the allowed input voltage and increase efficiency compared to the original part without making significant changes to ...

Harris, Cory Angelo

2014-01-01T23:59:59.000Z

271

Voltage Regulator Chip: Power Supplies on a Chip  

SciTech Connect

ADEPT Project: CPES at Virginia Tech is finding ways to save real estate on a computer's motherboard that could be used for other critical functions. Every computer processor today contains a voltage regulator that automatically maintains a constant level of electricity entering the device. These regulators contain bulky components and take up about 30% of a computer's motherboard. CPES at Virginia Tech is developing a voltage regulator that uses semiconductors made of gallium nitride on silicon (GaN-on-Si) and high-frequency soft magnetic material. These materials are integrated on a small, 3D chip that can handle the same amount of power as traditional voltage regulators at 1/10 the size and with improved efficiency. The small size also frees up to 90% of the motherboard space occupied by current voltage regulators.

None

2010-09-01T23:59:59.000Z

272

Reactive Support and Voltage Control Service: Key Issues and Challenges  

E-Print Network (OSTI)

Reactive Support and Voltage Control Service: Key Issues and Challenges George Gross^, Paolo of Illinois at Urbana-Champaign, Urbana, IL 61801, USA, e-mail gross@uiuc.edu ° Dipartimento di Ingegneria

Gross, George

273

Automotive high-voltage electrical system with integrated safeguard  

Science Journals Connector (OSTI)

For several years the use of higher system voltages has been a topic in the automotive industry. Whether for hybrid or conventional vehicles, safeguards are required which protect both the vehicle...

Thomas Flottmann

2007-03-01T23:59:59.000Z

274

Modeling the operating voltage of liquid metal battery cells  

E-Print Network (OSTI)

A one-dimensional, integrative model of the voltage during liquid metal battery operation has been developed to enhance the understanding of performance at the cell level. Two liquid metal batteries were studied: Mg-Sb for ...

Newhouse, Jocelyn Marie

2014-01-01T23:59:59.000Z

275

Voltage Fade, an ABR Deep Dive Project: Status and Outcomes  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Budget * Voltage Fade project * 3,900K Barriers * Calendarcycle life of lithium-ion cells being developed for PHEV and EV batteries that meet or exceed DOEUSABC goals Partners...

276

High Voltage Electrolytes for Li-ion Batteries | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

in Support of 5 V Li-ion Chemistries Vehicle Technologies Office Merit Review 2014: Fluorinated Electrolyte for 5-V Li-Ion Chemistry High Voltage Electrolyte for Lithium Batteries...

277

High voltage dry-type air-core shunt reactors  

Science Journals Connector (OSTI)

Dry-type air-core shunt reactors are now being ... systems to limit overvoltages. Recently, high voltage dry-type air-core shunt reactors have been designed, ... transient overvoltages and electrical and magnetic...

Klaus Papp; Michael R. Sharp…

2014-11-01T23:59:59.000Z

278

High-speed low-voltage ultraviolet light source  

Science Journals Connector (OSTI)

A novel quasi-spark gap has been designed and constructed with high-speed and low-spark voltage characteristics. Ultraviolet light generating sparks can be operated at a rate of up to...

Huang, L; Hsu, S C; Kwok, H S

1984-01-01T23:59:59.000Z

279

Advanced Vehicle Testing Activity: Medium- and Heavy-Duty Vehicles  

NLE Websites -- All DOE Office Websites (Extended Search)

Medium- and Medium- and Heavy-Duty Vehicles to someone by E-mail Share Advanced Vehicle Testing Activity: Medium- and Heavy-Duty Vehicles on Facebook Tweet about Advanced Vehicle Testing Activity: Medium- and Heavy-Duty Vehicles on Twitter Bookmark Advanced Vehicle Testing Activity: Medium- and Heavy-Duty Vehicles on Google Bookmark Advanced Vehicle Testing Activity: Medium- and Heavy-Duty Vehicles on Delicious Rank Advanced Vehicle Testing Activity: Medium- and Heavy-Duty Vehicles on Digg Find More places to share Advanced Vehicle Testing Activity: Medium- and Heavy-Duty Vehicles on AddThis.com... Home Overview Light-Duty Vehicles Medium- and Heavy-Duty Vehicles Transit Vehicles Trucks Idle Reduction Oil Bypass Filter Airport Ground Support Equipment Medium and Heavy Duty Hybrid Electric Vehicles

280

LM111/LM211/LM311 Voltage Comparator  

E-Print Network (OSTI)

LM111/LM211/LM311 Voltage Comparator 1.0 General Description The LM111, LM211 and LM311 are voltage comparators that have input currents nearly a thousand times lower than devices like the LM106 or LM710A. Both the inputs and the outputs of the LM111, LM211 or the LM311 can be isolated from system ground

Lanterman, Aaron

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Sinusoidal voltage controlled oscillators using operational transconductance amplifiers  

E-Print Network (OSTI)

SINUSOIDAI. VOLTAGE CONTROLLED OSCILLATORS I. SING OPERATIONAL TRANSCONDUCTANCE AMPLIFIERS A Thesis JAVIFB . IOAQUIN HOYI. K I'ASSANO Suhndtted to the Graduate College ol' 'I'exes A8cM University in partial fulfillment of the requirement... for the degree of MASTER OF SCIENCE May 1985 Major Subject: Electrical Engineering SINUSOIDAL VOLTAGE CONTROLLED OSCILLATORS USING OPERATIONAI, TRANSCONDUCTANCE AMPLIFIERS A Thesis by JAVIER JOAQUIN HOYLE PASSANO Approved as to style and content by: o...

Hoyle Passano, Javier Joaquin

1985-01-01T23:59:59.000Z

282

Image-line voltage controlled oscillators and grating antennas  

E-Print Network (OSTI)

IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Submitted to the Office of Graduate Studies of Texas ABM University in partial fulfillment of the requirements for the degree of MASTER... OF SCIENCE May 1991 Major Subject: Electrical Engineering IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Approved as to style and content by: Kai Chang (Chair of Committee) Robert D. Nevels...

Kirk, Alexander MacDonald

1991-01-01T23:59:59.000Z

283

Design issues for high voltage converters for ion engines  

SciTech Connect

A design strategy is presented for a power converter for a high voltage ion engine for a spacecraft application. Various design issues such as appropriate topologies and control methods are considered. In this particular instance it was determined that a full bridge converter with phase shift gating and voltage mode control provided an efficient system with a minimum of electromagnetic interference. This system can be implemented in a straightforward manner, and it is relatively easy to protect from faults at the output.

King, R.J.; Stuart, T.A. [Univ. of Toledo, OH (United States)

1995-12-31T23:59:59.000Z

284

Impact of Increasing Distributed Wind Power and Wind Turbine Siting on Rural Distribution Feeder Voltage Profiles: Preprint  

SciTech Connect

Many favorable wind energy resources in North America are located in remote locations without direct access to the transmission grid. Building transmission lines to connect remotely-located wind power plants to large load centers has become a barrier to increasing wind power penetration in North America. By connecting utility-sized megawatt-scale wind turbines to the distribution system, wind power supplied to consumers could be increased greatly. However, the impact of including megawatt-scale wind turbines on distribution feeders needs to be studied. The work presented here examined the impact that siting and power output of megawatt-scale wind turbines have on distribution feeder voltage. This is the start of work to present a general guide to megawatt-scale wind turbine impact on the distribution feeder and finding the amount of wind power that can be added without adversely impacting the distribution feeder operation, reliability, and power quality.

Allen, A.; Zhang, Y. C.; Hodge, B. M.

2013-09-01T23:59:59.000Z

285

Low Voltage Electrostatic Actuation and Displacement Measurement through Resonant Drive Circuit.  

E-Print Network (OSTI)

??An electrostatic actuator driven by conventional voltage control and charge control requires high actuation voltage and suffers from the pull-in phenomenon that limits its operation… (more)

Park, Sangtak

2011-01-01T23:59:59.000Z

286

Modeling Electric Vehicle Benefits Connected to Smart Grids  

E-Print Network (OSTI)

Vehicle Benefits Connected to Smart Grids M. Stadler 1,2,a ,Electric Vehicle Benefits Connected to Smart Grids Michael

Stadler, Michael

2012-01-01T23:59:59.000Z

287

Integrated, Low Voltage, DynamicallyIntegrated, Low Voltage, Dynamically Adaptive BuckAdaptive Buck--Boost ConverterBoost Converter  

E-Print Network (OSTI)

Improvement in battery life Low voltage Single cell operation (Li-ion/NiCd/NiMH/Fuel Cell) Integrated Linearity degradation #12;55Georgia Tech Analog Consortium Biranchinath Sahu School of Electrical

Rincon-Mora, Gabriel A.

288

Medium-fi EvaluationMedium-fi PrototypesMedium-fi DesignLow-fi EvaluationLow-fi Prototypes What is Aphasia?  

E-Print Network (OSTI)

Medium-fi EvaluationMedium-fi PrototypesMedium-fi DesignLow-fi EvaluationLow-fi Prototypes What Cycle Investigated ability of existing technologies to fulfill needs. Extra time is needed to ensure. Evaluated with two participants. One had aphasia as a result of a brain tumour and the other as a result

Findlater, Leah

289

SciTech Connect: Optical Observations of Gamma-Ray Bursts: Connections...  

Office of Scientific and Technical Information (OSTI)

Conference: Optical Observations of Gamma-Ray Bursts: Connections to GeVTeV Jets Citation Details In-Document Search Title: Optical Observations of Gamma-Ray Bursts: Connections...

290

College of Health Sciences Health Sciences Connection  

E-Print Network (OSTI)

College of Health Sciences Health Sciences Connection 1 Dean's Message College of Health Sciences Health Sciences Connection December 2009 January 2010 Volume VIII (5) Moving from the Superficial the superficial level so that the result is the formation of deep relationships, caring, compassion, justice, love

Barrash, Warren

291

College of Health Sciences Health Sciences Connection  

E-Print Network (OSTI)

today. In politics, in education, in health care, in society in general we are so turned inwardCollege of Health Sciences Health Sciences Connection 1 Dean's Message College of Health Sciences Health Sciences Connection April/May 2010 Volume VIII (8) WOW! Spring semester of 2010 is almost

Barrash, Warren

292

College of Health Sciences Health Sciences Connection  

E-Print Network (OSTI)

College of Health Sciences Health Sciences Connection 1 Dean's Message College of Health Sciences Health Sciences Connection April 2011 Volume IX (4) The end of the spring semester is quickly approaching accreditation review. Similarly, the Environmental and Occupational Health program also had a very positive

Barrash, Warren

293

College of Health Sciences Health Sciences Connection  

E-Print Network (OSTI)

, College of Health Sciences. · "Innovative Ways to Address Idaho's Healthcare Needs: Long-Term CareCollege of Health Sciences Health Sciences Connection 1 Dean's Message College of Health Sciences Health Sciences Connection February 2011 Volume IX (3) Since the last COHS newsletter, the faculty

Barrash, Warren

294

The Impact of Galactic Feedback on the Circumgalactic Medium  

E-Print Network (OSTI)

Galactic feedback strongly affects the way galactic environments are enriched. We examine this connection by performing a suite of cosmological hydrodynamic simulations, exploring a range of parameters based on the galaxy formation model developed in Vogelsberger et al. 2013 (henceforth V13). We examine the effects of AGN feedback, wind mass loading, wind specific energy, and wind metal-loading on the properties of the circumgalactic medium (CGM) of galaxies with $M_\\text{halo} > 10^{11} M_\\odot$. Note that while the V13 model was tuned to match observations including the stellar mass function, no explicit tuning was done for the CGM. The wind energy per unit outflow mass has the most significant effect on the CGM enrichment. High energy winds launch metals far beyond the virial radius. AGN feedback also has a significant effect, but only at $z < 3$. We compare to high redshift HI and CIV observations. All our simulations produce the observed number of Damped Lyman-$\\alpha$ Absorbers. At lower column densi...

Suresh, Joshua; Vogelsberger, Mark; Genel, Shy; Torrey, Paul; Sijacki, Debora; Springel, Volker; Hernquist, Lars

2015-01-01T23:59:59.000Z

295

Fluid breakup during simultaneous two-phase flow through a three-dimensional porous medium  

E-Print Network (OSTI)

We use confocal microscopy to directly visualize the simultaneous flow of both a wetting and a non-wetting fluid through a model three-dimensional (3D) porous medium. We find that, for small flow rates, both fluids flow through unchanging, distinct, connected 3D pathways; in stark contrast, at sufficiently large flow rates, the non-wetting fluid is broken up into discrete ganglia. By performing experiments over a range of flow rates, using fluids of different viscosities, and with porous media having different geometries, we show that this transition can be characterized by a state diagram that depends on the capillary numbers of both fluids, suggesting that it is controlled by the competition between the viscous forces exerted on the flowing oil and the capillary forces at the pore scale. Our results thus help elucidate the diverse range of behaviors that arise in two-phase flow through a 3D porous medium.

Sujit S. Datta; Jean-Baptiste Dupin; David A. Weitz

2014-06-26T23:59:59.000Z

296

Connecting the Americas 2022 | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Connecting the Americas 2022 Connecting the Americas 2022 Connecting the Americas 2022 April 16, 2012 - 8:42am Addthis At the Sixth Summit of the Americas in Cartagena, Colombia, the United States joined Colombia and other leaders of the Western Hemisphere in committing to achieve universal access to electricity over the next decade through enhanced electrical interconnection. This initiative, developed by Colombia and called "Connecting the Americas 2022"will increase access to reliable, clean, and affordable electricity for the region's 31 million citizens without it. Connecting the Americas 2022 supports the Energy and Climate Partnership of the Americas (ECPA), launched by President Obama at the 2009 Summit of the Americas, which promotes regional collaboration on low-carbon development, energy security, and climate

297

Instructions for WebVPN Connectivity  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Instructions for WebVPN Connectivity Instructions for WebVPN Connectivity November 2013 Requirements * Web Browser (Internet Explorer, Firefox, Safari, Internet Explorer, etc.) * Internet Connection (Preferably Broadband) * RSA Token or HSPD12 Smart Card Background The clientless WebVPN connectivity option being offered by the OCIO significantly enhances the speed as well as the interoperability between different operating systems/Internet service providers (ISP) which results in an improved overall user experience when using VPN services to access corporate applications remotely. WebVPN allows a remote user to access Outlook Web Access, Citrix Workplace Environment (CWE), and other web-based applications from any computer with an Internet connection, with no requirement for additional software to be downloaded and installed to the remote machine.

298

Physical vacuum is a special superfluid medium  

E-Print Network (OSTI)

The Navier-Stokes equation contains two terms which have been subjected to slight modification: (a) the viscosity term depends of time (the viscosity in average on time is zero, but its variance is non-zero); (b) the pressure gradient contains an added term describing the quantum entropy gradient multiplied by the pressure. Owing to these modifications, the Navier-Stokes equation can be reduced to the Schr\\"odinger equation describing behavior of a particle into the vacuum being as a superfluid medium. Vortex structures arising in this medium show infinitely long life owing to zeroth average viscosity. The non-zero variance describes exchange of the vortex energy with zero-point energy of the vacuum. Radius of the vortex trembles around some average value. This observation sheds the light to the Zitterbewegung phenomenon. The long-lived vortex has a non-zero core where the vortex velocity vanishes.

Sbitnev, Valeriy I

2015-01-01T23:59:59.000Z

299

Transient multiwave mixing in a nonlinear medium  

Science Journals Connector (OSTI)

We present a detailed quantitative theory of transient multiwave mixing effects in a nonlinear medium produced by two incident coherent laser beams. Our theory accounts for all the relevant parameters such as laser pulse widths, medium response times, nonlinearities, interaction length, intensities, beam ratio, phase-modulation effects, losses, side diffractions, and explicitly shows how the dynamics and the multiwave mixing processes are interrelated with these parameters. The crucial role played by the diffracted beams and the time-dependent phase shifts among the beams and the interplay among the various intensity and index gratings are explicitly evaluated. In particular, the gain experienced by a weak incident probe beam via these mixing effects from the incident strong pump beam is investigated as a function of the aforementioned parameters.

I. C. Khoo and Ping Zhou

1990-02-01T23:59:59.000Z

300

JC3 Medium Impact Assessment Bulletins  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

medium-impact-assessment-bulletins medium-impact-assessment-bulletins Office of the Chief Information Officer 1000 Independence Ave., SW Washington, DC 202-586-0166 en V-237: TYPO3 Security Bypass Vulnerabilities http://energy.gov/cio/articles/v-237-typo3-security-bypass-vulnerabilities V-237: TYPO3 Security Bypass Vulnerabilities

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Note: On the number of connected convex subgraphs of a connected acyclic digraph  

Science Journals Connector (OSTI)

A digraph D is connected if the underlying undirected graph of D is connected. A subgraph H of an acyclic digraph D is convex if there is no directed path between vertices of H which contains an arc not in H. We find the minimum and maximum possible ... Keywords: Acyclic digraphs, Connected subgraphs, Convex subgraphs, Enumeration

Gregory Gutin; Anders Yeo

2009-04-01T23:59:59.000Z

302

Simulation of a new grid-connected hybrid generation system with Stirling engine and wind turbine  

Science Journals Connector (OSTI)

A detail model including all mechanical and electrical aspects is necessary to fully study hybrid grid operation. In this paper a new grid-connected hybrid generation system with a Stirling engine and a wind turbine which are connected to a grid through a common dc bus is presented. The Stirling is more efficient than photo voltaic array and its combination with the wind turbine can create an efficient hybrid system. Fatigue Aerodynamics Structures and Turbulence and Simulink/MATLAB are used to model the mechanical parts of the wind turbine Stirling engine and electrical parts. Field oriented control method is developed on voltage source converter. Power signal feedback method is implemented to determine generators reference shaft speed in hybrid system. Permanent magnet synchronous generator is used in the wind turbine and Stirling engine. Simulation results show that a new hybrid generation system with Stirling and wind turbine can work like other hybrid system and has suitable performance.

H. Shariatpanah; M. Zareian Jahromi; R. Fadaeinedjad

2013-01-01T23:59:59.000Z

303

Alternative Fuels Data Center: Medium-Duty Vehicle Idle Reduction  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Medium-Duty Vehicle Medium-Duty Vehicle Idle Reduction Strategies to someone by E-mail Share Alternative Fuels Data Center: Medium-Duty Vehicle Idle Reduction Strategies on Facebook Tweet about Alternative Fuels Data Center: Medium-Duty Vehicle Idle Reduction Strategies on Twitter Bookmark Alternative Fuels Data Center: Medium-Duty Vehicle Idle Reduction Strategies on Google Bookmark Alternative Fuels Data Center: Medium-Duty Vehicle Idle Reduction Strategies on Delicious Rank Alternative Fuels Data Center: Medium-Duty Vehicle Idle Reduction Strategies on Digg Find More places to share Alternative Fuels Data Center: Medium-Duty Vehicle Idle Reduction Strategies on AddThis.com... More in this section... Idle Reduction Benefits & Considerations Heavy-Duty Vehicles Medium-Duty Vehicles

304

Screening masses in thermal and dense medium  

E-Print Network (OSTI)

Screening masses of different hadronic states are studied in thermal and dense medium on lattice. It has been found that screening masses increase with the temperature. In deconfinement phase, chemical potential enhances the screening masses. We use the normalization with respect to lowest Matsubara frequency to characterize dissolving of hadronic bound states at high temperatures. It has been found that different hadronic states have different dissolving temperatures and their survivals are considerably improved at finite chemical potentials.

A. Tawfik

2006-05-29T23:59:59.000Z

305

Exploring medium effects on the nuclear force  

SciTech Connect

This STI product contains a description of results from theoretical studies in nuclear physics. The goal is a systematic investigation of the nuclear force in the nuclear medium. The problems addressed are: density-dependent effective interactions as seen through proton-nucleus reactions, nuclear matter with unequal densities of protons and neutrons, applications to asymmetric nuclei through predictions of neutron radii and neutron skins.

F. Sammarruca

2004-04-18T23:59:59.000Z

306

Exploration of the comics medium developed for use on the internet  

E-Print Network (OSTI)

of a given site or made available to be downloaded. Finally, in what is possibly the greatest separation from the two-dimensionality of the printed medium, the advancement of V R M L (virtual reality markup language) on the internet allows for a... as the speed of the internet connection, could have a dramatically different experience within a common web site. It is evident that the internet, much like traditional printed work, has its own limita tions. Ultimately, however, it also has ever...

Piana, Brian James

2012-06-07T23:59:59.000Z

307

Optimisation of voltage and frequency regulation in an isolated wind-driven six-phase self-excited induction generator  

Science Journals Connector (OSTI)

Abstract This paper presents a constant voltage operation of a Six-Phase Self-Excited Induction Generator (SPSEIG) driven by a fixed speed wind turbine using an Ant colony optimisation (ACO) technique to predict the behaviour of a the machine. In this paper, an attempt has been made to estimate the excitation capacitance requirements of a SPSEIG for maintaining rated terminal voltage and frequency. The range of capacitance variation required for maintaining constant terminal voltage while supplying a load of variable magnitude is evaluated. Analytical approaches, suitable for all the configurations of shunt capacitances such as variable excitation capacitance connected across (i) single three-phase winding set only and (ii) both the three-phase winding sets of an SPSEIG for operation as a simple shunt on no load and pure resistive load, are presented. The mathematical model developed is based on loop impedance method using graph theory. It is shown that the proposed technique is very effective and useful for making the SPSEIG feasible for remote areas with wind potential. The proposed approach is tested and compared with Genetic Algorithm (GA) and Fmincon technique.

A. Senthil Kumar; Josiah L. Munda

2014-01-01T23:59:59.000Z

308

Minimization of voltage deviation and power losses in power networks using Pareto optimization methods  

Science Journals Connector (OSTI)

Voltage regulation is an important task in electrical engineering for controlling node voltages in a power network. A widely used solution for the problem of voltage regulation is based on adjusting the taps in under load tap changers (ULTCs) power transformers ... Keywords: Multi-objective optimization, Power distribution network, Power losses, Under load tap changers, Voltage regulation

Francisco G. Montoya; Raúl Bańos; Consolación Gil; Antonio Espín; Alfredo Alcayde; Julio Gómez

2010-08-01T23:59:59.000Z

309

Requirements for a Standard Test to Rate the Durability of PV Modules at System Voltage (Presentation)  

SciTech Connect

Degradation modes in photovoltaic modules under system bias voltage stress are described and classified.

Hacke, P.; Terwilliger, K.; Glick, S.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-02-01T23:59:59.000Z

310

Summaries of Addresses of Presidents of Sections: High-Voltage Insulation  

Science Journals Connector (OSTI)

... subject of his presidential address to Section A (Mathematics and Physics) *'High-voltage Insulation".

1963-08-31T23:59:59.000Z

311

Elevated voltage level I.sub.DDQ failure testing of integrated circuits  

DOE Patents (OSTI)

Burn in testing of static CMOS IC's is eliminated by I.sub.DDQ testing at elevated voltage levels. These voltage levels are at least 25% higher than the normal operating voltage for the IC but are below voltage levels that would cause damage to the chip.

Righter, Alan W. (Albuquerque, NM)

1996-01-01T23:59:59.000Z

312

Elevated voltage level I{sub DDQ} failure testing of integrated circuits  

DOE Patents (OSTI)

Burn in testing of static CMOS IC`s is eliminated by I{sub DDQ} testing at elevated voltage levels. These voltage levels are at least 25% higher than the normal operating voltage for the IC but are below voltage levels that would cause damage to the chip. 4 figs.

Righter, A.W.

1996-05-21T23:59:59.000Z

313

High voltage stability performance of a gamma ray detection device  

SciTech Connect

An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

Abdullah, Nor Arymaswati; Lombigit, Lojius; Rahman, Nur Aira Abd [Technical Support Division, Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)

2014-02-12T23:59:59.000Z

314

Voltage Impacts of Utility-Scale Distributed Wind  

SciTech Connect

Although most utility-scale wind turbines in the United States are added at the transmission level in large wind power plants, distributed wind power offers an alternative that could increase the overall wind power penetration without the need for additional transmission. This report examines the distribution feeder-level voltage issues that can arise when adding utility-scale wind turbines to the distribution system. Four of the Pacific Northwest National Laboratory taxonomy feeders were examined in detail to study the voltage issues associated with adding wind turbines at different distances from the sub-station. General rules relating feeder resistance up to the point of turbine interconnection to the expected maximum voltage change levels were developed. Additional analysis examined line and transformer overvoltage conditions.

Allen, A.

2014-09-01T23:59:59.000Z

315

Operability and Emissions from a Medium-Duty Fleet Operating...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Operability and Emissions from a Medium-Duty Fleet Operating with GTL Fuel and Catalyzed DPFs Operability and Emissions from a Medium-Duty Fleet Operating with GTL Fuel and...

316

REFINED BOUNDS ON THE NUMBER OF CONNECTED ...  

E-Print Network (OSTI)

Nov 6, 2011 ... closure imply using the well-known Smith inequality (see Theorem 2.4) a bound on the number of semi-algebraically connected components of ...

2011-11-06T23:59:59.000Z

317

Autonomic Communication with RASCAL Hybrid Connectivity Management  

Science Journals Connector (OSTI)

This paper presents an approach to manipulating available hybrid connectivity to autonomically maximise the potential for ... determine best options for packet transmission over available infrastructure and ad-ho...

Dominic Greenwood; Roberto Ghizzioli

2008-01-01T23:59:59.000Z

318

Energy Education BASS CONNECTIONS in ENERGY  

E-Print Network (OSTI)

Energy Education BASS CONNECTIONS in ENERGY Leader: Prof. Richard Newell Duke University Energy Initiative Energy education at Duke capitalizes on the University's broader Energy Initiative, a university-wide interdisciplinary collaboration addressing today's pressing energy challenges related to the economy

Ferrari, Silvia

319

USDA Rural Small Business Connection Event  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Agriculture (USDA) will host Rural Small Business Connections, providing small businesses with networking sessions and opportunities to build capacity and do business with USDA and other Federal agencies.

320

Connecting to the Grid | GE Global Research  

NLE Websites -- All DOE Office Websites (Extended Search)

of ARPA-e, we're working on a project to develop a DC fault-resilient modular DCDC transformer that would enable renewable power systems, like a wind farm, to connect directly to...

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Self-Excited ac High Voltage Generation Using Water Droplets  

Science Journals Connector (OSTI)

By letting water drops fall through rings into cans high voltage can be spontaneously generated with no external electrical excitation. Previous work concerning this type of electric influence machine for dc and three-phase ac high voltage generation is extended to include multiphase multifrequency operation by considering N streams and N cans. A distributed equivalent circuit representation is used to calculate the natural frequencies of the system where it is found that many overstable modes are present. Experimental observations with up to five cans are presented. This device can serve as a model for phenomena concerned with atmospheric electricity.

Markus Zahn

1973-01-01T23:59:59.000Z

322

Voltage Control Devices on the IEEE 8500 Node Test Feeder  

SciTech Connect

The IEEE Test Cases provide researchers with distribution system models that can be used to validate new analytic methods. The newest of these models is the 8500-node test feeder which contains multiple devices for voltage control. In addition to a substation regulator there are multiple inline regulators as well as capacitor banks. This paper will discuss the detail in which voltage control devises should be modeled when examining large distribution systems. This discussion will include issues associated with power flow analysis for a single time step as well as for time series analysis.

Schneider, Kevin P.; Fuller, Jason C.

2010-01-06T23:59:59.000Z

323

Zone heated diesel particulate filter electrical connection  

DOE Patents (OSTI)

An electrical connection system for a particulate filter is provided. The system includes: a particulate filter (PF) disposed within an outer shell wherein the PF is segmented into a plurality of heating zones; an outer mat disposed between the particulate filter and the outer shell; an electrical connector coupled to the outer shell of the PF; and a plurality of printed circuit connections that extend along the outer surface of the PF from the electrical connector to the plurality of heating zones.

Gonze, Eugene V. (Pinckney, MI); Paratore, Jr., Michael J. (Howell, MI)

2010-03-30T23:59:59.000Z

324

Conditions for Capacitor Voltage Regulation in a Five-Level Cascade Multilevel Inverter: Application to Voltage-Boost in a PM Drive  

E-Print Network (OSTI)

Conditions for Capacitor Voltage Regulation in a Five-Level Cascade Multilevel Inverter Abstract-- A cascade multilevel inverter is a power electronic device built to synthesize a desired AC voltage from several levels of DC voltages. Such inverters have been the subject of research in the last

Tolbert, Leon M.

325

Low Beam Voltage, 10 MW, L-Band Cluster Klystron  

SciTech Connect

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

Teryaev, V.; /Novosibirsk, IYF; Yakovlev, V.P.; /Fermilab; Kazakov, S.; /KEK, Tsukuba; Hirshfield, J.L.; /Yale U. /Omega-P, New Haven

2009-05-01T23:59:59.000Z

326

Power Grid Voltage Integrity Verification Department of ECE  

E-Print Network (OSTI)

Power Grid Voltage Integrity Verification Maha Nizam Department of ECE University of Toronto devgan@magma-da.com ABSTRACT Full-chip verification requires one to check if the power grid is safe, i of the circuit attached to the grid, thereby precluding early verification of the grid. We propose a power grid

Najm, Farid N.

327

Voltage Regulation through Smart Utilization of Potential Reactive Power Resources  

Science Journals Connector (OSTI)

The introduction of demand response concept, in addition to increment of penetration of distributed generation (DG) based on renewable energies, make opportunities for the novel control schemes to be integrated in power system on a smart grid framework. ... Keywords: Demand response, distributed generation, reactive power, renewable energy, smart grid, voltage control

H. Kazari; A. Abbaspour-Tehrani Fard; A. S. Dobakhshari; A. M. Ranjbar

2011-11-01T23:59:59.000Z

328

ORIGINAL ARTICLES Induced Transmembrane Voltage and Its Correlation  

E-Print Network (OSTI)

to investigate the correlation between DWm and molecular transport through an elec- troporated membrane to a voltage (electric potential difference) caused by a system of ion pumps and channels in the membrane, or electropermea- bilization, and permits transmembrane transport of mole- cules for which an intact membrane

Ljubljana, University of

329

Topical Review Voltage Dependence of the Na/K Pump  

E-Print Network (OSTI)

or ``ion well'' hy- pothesis. There are only two ways that net transport can be voltage dependent. Either of the external Na+ and K+ bind- ing sites within the membrane field. This access channel or ``ion well produced by applying a blocking Key words: Na,K-ATPase -- Membrane potential -- Access channel -- Ion well

Gadsby, David

330

Current isolating epitaxial buffer layers for high voltage photodiode array  

DOE Patents (OSTI)

An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

2002-01-01T23:59:59.000Z

331

Load Balancing in Wireless Sensor Networks using Kirchhoff's Voltage Law  

E-Print Network (OSTI)

Load Balancing in Wireless Sensor Networks using Kirchhoff's Voltage Law Stavros Toumpis Electrical balancing in wireless networks with a single class of traffic, focusing our attention on an important example, i.e., Wireless Sensor Networks. The analysis is based on the Wireless Minimum Cost Problem

Toumpis, Stavros

332

Power and Voltage Smooth Control of Doubly Fed Induction Generator  

Science Journals Connector (OSTI)

Doubly-fed induction generator (DFIG) is the leading in wind power technology currently. In this paper, decoupling control of DFIG is studied and a new energy storage device is used in the smooth control of DFIG system's power and voltage. This new method ... Keywords: Doubly fed induction generator, Energy storage device, Decoupling control

An-Ren Ma; Cai-Xia Wang; Zhi-Wen Zhou; Tao Wu

2012-07-01T23:59:59.000Z

333

Analysis on DFIG Wind Power System Low-Voltage Ridethrough  

Science Journals Connector (OSTI)

Due to the double fed induction generator’s (DFIG) advantage of controlling active and reactive power independently and partial power converter, DFIG is becoming a popular type of wind power generation system. Nowadays, the grid code demands that ... Keywords: VSCF, DFIG, LVRT, Crowbar, Voltage sags

Yulong Wang; Jianlin Li; Shuju Hu; Honghua Xu

2009-04-01T23:59:59.000Z

334

SVC Voltage Regulator Based on Fractional Order PID  

Science Journals Connector (OSTI)

Contradiction exist between rapid and smooth in the dynamic adjustment process of SVC, however, Fractional order PID controller has two degrees of freedom more than the integer order PID controller, and it has better control performance. This article ... Keywords: SVC, Fractional order PID, Voltage regulator, Oustaloup

Manyu Liu; Huaying Dong; Guishu Liang

2012-12-01T23:59:59.000Z

335

Way to reduce arc voltage losses in hybrid thermionic converters  

SciTech Connect

Experimental results are reported concerning the output and emission characteristics of the arc and hybrid regimes in a plane-parallel thermionic converter with Pt--Zr--O electrode pair. It is shown that arc voltage losses can be reduced to values below those obtainable in ordinary arc thermionic converters.

Tskhakaya, V.K.; Yarygin, V.I.

1982-03-01T23:59:59.000Z

336

Field Optimization of Three Dimensional High Voltage C. Trinitis  

E-Print Network (OSTI)

Field Optimization of Three Dimensional High Voltage Equipment C. Trinitis Lehrstuhl f The goal of finding an optimal electric field strength distribution for arbitrary three di­ mensional­ cal optimization algorithm. The package ob­ tained from these three components is then able

Stamatakis, Alexandros

337

High voltage gas insulated transmission line with continuous particle trapping  

DOE Patents (OSTI)

This invention provides a novel high voltage gas insulated transmission line utilizing insulating supports spaced at intervals with snap-in means for supporting a continuous trapping apparatus and said trapping apparatus having perforations and cutouts to facilitate trapping of contaminating particles and system flexibility.

Cookson, Alan H. (Pittsburgh, PA); Dale, Steinar J. (Monroeville, PA)

1983-01-01T23:59:59.000Z

338

High Voltage DC Transmission 2 1.0 Introduction  

E-Print Network (OSTI)

1 High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires on use of switching devices collectively referred to in the HVDC community as valves. Valves may be non. Fig. 1 There have been three types of devices for implementing HVDC converter circuits: mercury

McCalley, James D.

339

Alternative Fuels Data Center: Medium-Speed and Neighborhood Electric  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Medium-Speed and Medium-Speed and Neighborhood Electric Vehicle (NEV) Definition and Access to Roadways to someone by E-mail Share Alternative Fuels Data Center: Medium-Speed and Neighborhood Electric Vehicle (NEV) Definition and Access to Roadways on Facebook Tweet about Alternative Fuels Data Center: Medium-Speed and Neighborhood Electric Vehicle (NEV) Definition and Access to Roadways on Twitter Bookmark Alternative Fuels Data Center: Medium-Speed and Neighborhood Electric Vehicle (NEV) Definition and Access to Roadways on Google Bookmark Alternative Fuels Data Center: Medium-Speed and Neighborhood Electric Vehicle (NEV) Definition and Access to Roadways on Delicious Rank Alternative Fuels Data Center: Medium-Speed and Neighborhood Electric Vehicle (NEV) Definition and Access to Roadways on Digg

340

Building Technologies Office: Small- and Medium-Sized Building Automation  

NLE Websites -- All DOE Office Websites (Extended Search)

Small- and Medium-Sized Small- and Medium-Sized Building Automation and Control System Needs: Scoping Study Research Project to someone by E-mail Share Building Technologies Office: Small- and Medium-Sized Building Automation and Control System Needs: Scoping Study Research Project on Facebook Tweet about Building Technologies Office: Small- and Medium-Sized Building Automation and Control System Needs: Scoping Study Research Project on Twitter Bookmark Building Technologies Office: Small- and Medium-Sized Building Automation and Control System Needs: Scoping Study Research Project on Google Bookmark Building Technologies Office: Small- and Medium-Sized Building Automation and Control System Needs: Scoping Study Research Project on Delicious Rank Building Technologies Office: Small- and Medium-Sized Building

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Apparatus for connecting aligned abutted tubes  

DOE Patents (OSTI)

An apparatus for connecting abutted tubes and for maintaining their rotary alignment during connection. The apparatus comprises first and second tubes, a rotation prevention element, a collar and a retainer. Each tube has inside and outside walls, and first and second ends, each end having an inside and outside edge. The first tube has portions defining a first plurality of cavities located at the outside edge of its first end. An external threaded portion is on the outside wall of the first tube and next to the first plurality of cavities. The second tube has portions defining a second plurality of cavities located at the outside edge of its first end. The first plurality has a different number than the second plurality. The first ends of the first and second tubes have substantially the same outside diameter and are abutted during connection so that an orifice is formed whenever first and second tube cavities substantially overlap. A rotation prevension element is placed in the orifice to prevent rotation of the first and second tubes. A collar with an internal threaded portion is slidably disposed about the second tube. The internal threaded portion engages the external threaded portion of the first tube to connect the tubes. A lip connected to the collar prevents separation of the collar from the second tube.

Williams, R.E.

1984-11-29T23:59:59.000Z

342

On the Virial Theorem for Interstellar Medium  

SciTech Connect

An attempt has been made to derive a version of the virial integral that would describe average properties of the interstellar medium (ISM). It is suggested to eliminate the (large) contribution of stellar matter by introducing 'exclusion zones' surrounding stars. Such an approach leads to the appearance of several types of additional surface integrals in the general expression. Their contribution depends on the rate of energy and matter exchange between the stars and ISM. If this exchange is weak, one can obtain a desired virial integral for ISM. However, the presence of intermittent large-scale energetic events significantly constrains the applicability of the virial theorem. If valid, the derived virial integral is dominated by cold molecular/atomic clouds, with only minor contribution of the global magnetic field and low-density warm part.

Ryutov, D

2007-09-24T23:59:59.000Z

343

Light Vector Mesons in the Nuclear Medium  

SciTech Connect

The light vector mesons ($\\rho$, $\\omega$, and $\\phi$) were produced in deuterium, carbon, titanium, and iron targets in a search for possible in-medium modifications to the properties of the $\\rho$ meson at normal nuclear densities and zero temperature. The vector mesons were detected with the CEBAF Large Acceptance Spectrometer (CLAS) via their decays to $e^{+}e^{-}$. The rare leptonic decay was chosen to reduce final-state interactions. A combinatorial background was subtracted from the invariant mass spectra using a well-established event-mixing technique. The $\\rho$ meson mass spectrum was extracted after the $\\omega$ and $\\phi$ signals were removed in a nearly model-independent way. Comparisons were made between the $\\rho$ mass spectra from the heavy targets ($A > 2$) with the mass spectrum extracted from the deuterium target. With respect to the $\\rho$-meson mass, we obtain a small shift compatible with zero. Also, we measure widths consistent with standard nuclear many-body eff

Wood, Michael; Nasseripour, Rakhsha; Weygand, Dennis; Djalali, Chaden; Tur, Clarisse; Mosel, Ulrich; Muehlich, Pascal; Adams, Gary; Amaryan, Moscov; Amaryan, Moskov; Ambrozewicz, Pawel; Anghinolfi, Marco; Asryan, Gegham; Avagyan, Harutyun; Baghdasaryan, Hovhannes; Baillie, Nathan; Ball, James; Baltzell, Nathan; Barrow, Steve; Battaglieri, Marco; Bedlinskiy, Ivan; Bektasoglu, Mehmet; Bellis, Matthew; Benmouna, Nawal; Berman, Barry; Biselli, Angela; Blaszczyk, Lukasz; Bouchigny, Sylvain; Boyarinov, Sergey; Bradford, Robert; Branford, Derek; Briscoe, William; Brooks, William; Burkert, Volker; Butuceanu, Cornel; Calarco, John; Careccia, Sharon; Carman, Daniel; Carnahan, Bryan; Casey, Liam; Chen, Shifeng; Cheng, Lu; Cole, Philip; Collins, Patrick; Coltharp, Philip; Crabb, Donald; Crannell, Hall; Crede, Volker; Cummings, John; Dashyan, Natalya; De Vita, Raffaella; De Sanctis, Enzo; Degtiarenko, Pavel; Denizli, Haluk; Dennis, Lawrence; Deur, Alexandre; Dharmawardane, Kahanawita; Dickson, Richard; Dodge, Gail; Doughty, David; Dugger, Michael; Dytman, Steven; Dzyubak, Oleksandr; Egiyan, Hovanes; Egiyan, Kim; Elfassi, Lamiaa; Elouadrhiri, Latifa; Eugenio, Paul; Fedotov, Gleb; Feldman, Gerald; Feuerbach, Robert; Fradi, Ahmed; Funsten, Herbert; Garcon, Michel; Gavalian, Gagik; Gilfoyle, Gerard; Giovanetti, Kevin; Girod, Francois-Xavier; Goetz, John; Gordon, Christopher; Gothe, Ralf; Griffioen, Keith; Guidal, Michel; Guler, Nevzat; Guo, Lei; Gyurjyan, Vardan; Hadjidakis, Cynthia; Hafidi, Kawtar; Hakobyan, Hayk; Hakobyan, Rafael; Hanretty, Charles; Hardie, John; Hassall, Neil; Hersman, F.; Hicks, Kenneth; Hleiqawi, Ishaq; Holtrop, Maurik; Hyde, Charles; Ilieva, Yordanka; Ireland, David; Ishkhanov, Boris; Isupov, Evgeny; Ito, Mark; Jenkins, David; Jo, Hyon-Suk; Johnstone, John; Joo, Kyungseon; Juengst, Henry; Kalantarians, Narbe; Kellie, James; Khandaker, Mahbubul; Khetarpal, Puneet; Kim, Wooyoung; Klein, Andreas; Klein, Franz; Klimenko, Alexei; Kossov, Mikhail; Krahn, Zebulun; Kramer, Laird; Kubarovsky, Valery; Kuhn, Joachim; Kuhn, Sebastian; Kuleshov, Sergey; Lachniet, Jeff; Laget, Jean; Langheinrich, Jorn; Lawrence, David; Li, Ji; Livingston, Kenneth; Lu, Haiyun; MacCormick, Marion; Markov, Nikolai; Mattione, Paul; McAleer, Simeon; McKinnon, Bryan; McNabb, John; Mecking, Bernhard; Mehrabyan, Surik; Melone, Joseph; Mestayer, Mac; Meyer, Curtis; Mibe, Tsutomu; Mikhaylov, Konstantin; Minehart, Ralph; Mirazita, Marco; Miskimen, Rory; Mokeev, Viktor; Moriya, Kei; Morrow, Steven; Moteabbed, Maryam; Mueller, James; Munevar Espitia, Edwin; Mutchler, Gordon; Nadel-Turonski, Pawel; Niccolai, Silvia; Niculescu, Gabriel; Niculescu, Maria-Ioana; Niczyporuk, Bogdan; Niroula, Megh; Niyazov, Rustam; Nozar, Mina; Osipenko, Mikhail; Ostrovidov, Alexander; Park, Kijun; Pasyuk, Evgueni; Paterson, Craig; Pereira, Sergio; Pierce, Joshua; Pivnyuk, Nikolay; Pocanic, Dinko; Pogorelko, Oleg; Pozdnyakov, Sergey; Preedom, Barry; Price, John; Prok, Yelena; Protopopescu, Dan; Raue, Brian; Riccardi, Gregory; Ricco, Giovanni; Ripani, Marco; Ritchie, Barry; Ronchetti, Federico; Rosner, Guenther; Rossi, Patrizia; Sabatie, Franck; Salamanca, Julian; Salgado, Carlos; Santoro, Joseph; Sapunenko, Vladimir; Schumacher, Reinhard; Serov, Vladimir; Sharabian, Youri; Sharov, Dmitri; Shvedunov, Nikolay; Smith, Elton; Smith, Lee; Sober, Daniel; Sokhan, Daria; Stavinsky, Aleksey; Stepanyan, Stepan; Stepanyan, Samuel; Stokes, Burnham; Stoler, Paul; Strakovski, Igor; Strauch, Steffen; Taiuti, Mauro; Tedeschi, David; Tkabladze, Avtandil; Tkachenko, Svyatoslav; Todor, Luminita; Ungaro, Maurizio; Vineyard, Michael; Vlassov, Alexander; Watts, Daniel; Weinstein, Lawrence; Williams, Michael; Wolin, Elliott; Yegneswaran, Amrit; Zana, Lorenzo; Zhang, Bin; Zhang, Jixie; Zhao, Bo; Zhao, Zhiwen

2008-07-01T23:59:59.000Z

344

Orthopositronium-orthopositronium scattering at medium energies  

SciTech Connect

The scattering of ortho-positronium (o-Ps) atoms has been investigated using the first Born approximation (FBA) and Born-Oppenheimer (B-O) model at medium energies. The angle integrated total elastic cross sections of o-Ps-o-Ps scattering have been reported. Apart from this, the inelastic cross sections for discrete excitations (principal quantum number, n{<=}3) of the single and both the Ps atoms as well as single and double Ps atom ionization have also been obtained. We have also predicted the total cross section of o-Ps-o-Ps scattering by adding all these partial cross sections. The first Born and B-O scattering amplitudes have also been evaluated using partial wave technique. It has been noticed that odd values of the partial wave B-O amplitude vanishes for even parity transitions and vice versa. To the best of our knowledge, this feature has not been noticed for other systems.

Chakraborty, Sumana; Ghosh, A.S. [Department of Theoretical Physics, Indian Association for the Cultivation of Science, Jadavpur, Kolkata-700 032 (India); Kumari, Kiran [Department of Physics, R N College, Hajipur (Vaishali), B R A Bihar University, Muzaffarpur, Bihar (India)

2005-08-15T23:59:59.000Z

345

Optimizing Medium Baseline Reactor Neutrino Experiments  

E-Print Network (OSTI)

10 years from now medium baseline reactor neutrino experiments will attempt to determine the neutrino mass hierarchy from the observed antineutrino spectra. In this letter we present the results of more than four million detailed simulations of such experiments, studying the dependence of the probability of successfully determining the hierarchy upon the analysis method, the neutrino mass matrix parameters, reactor flux models and, in particular, combinations of baselines. We show that the strong dependence of the hierarchy determination upon mass differences and flux models found by Qian et al. results from a spurious dependence of the Fourier analysis upon the high energy tail of the reactor spectrum which can be removed by using a weighted Fourier transform. Such experiments necessarily use flux from multiple reactors at distinct baselines, smearing the oscillation signal and thus impeding the determination of the hierarchy. Using the results of our simulations, we determine the optimal baselines and corre...

Ciuffoli, Emilio; Zhang, Xinmin

2013-01-01T23:59:59.000Z

346

Integration Technology for PHEV-Grid-Connectivity, with Support...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Technology for PHEV-Grid-Connectivity, with Support for SAE Electrical Standards Integration Technology for PHEV-Grid-Connectivity, with Support for SAE Electrical Standards 2010...

347

Nevada Deploys Grid-Connected Electricity from Enhanced Geothermal...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Nevada Deploys Grid-Connected Electricity from Enhanced Geothermal Systems Nevada Deploys Grid-Connected Electricity from Enhanced Geothermal Systems May 16, 2013 - 12:00am Addthis...

348

Connected Energy Corp | Open Energy Information  

Open Energy Info (EERE)

Connected Energy Corp Connected Energy Corp Jump to: navigation, search Name Connected Energy Corp Place Rochester, New York Zip 14614 Product Developer of the Central Operation Management System (COMSYS). Coordinates 43.1555°, -77.616033° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":43.1555,"lon":-77.616033,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

349

WindConnect | Open Energy Information  

Open Energy Info (EERE)

WindConnect WindConnect Jump to: navigation, search Name WindConnect Place Madison, Wisconsin Zip 53707-1007 Sector Services Product Unit of Alliant Energy. It provides turnkey services such as design, engineering, and construction. Coordinates 43.07295°, -89.386694° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":43.07295,"lon":-89.386694,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

350

Connecting the Molecular and the Continuum Scales  

NLE Websites -- All DOE Office Websites (Extended Search)

Connecting the Connecting the Molecular and the Continuum Scales Connecting the Molecular and the Continuum Scales Key Challenges: A molecular-scale understanding of structure and surface chemistry of clay mineral surface nanoparticles. Why it Matters: With a ubiquitous presence in natural materials and strong surface reactions, nanoparticles figure importantly in a broad range of phenomena, from climate change to contaminant remediation. Accomplishments: Used molecular dynamics (MD) simulations to determine molecular-scale diffusion coefficients of water tracers and representative cations (Na+,Cs+,Sr2+) in Smectite and found a simple way to accurately relate this to bulk, pore-scale diffusion. The result is that a remarkably simple expression relates Dinterlayer to the pore-scale

351

EnergyConnect | Open Energy Information  

Open Energy Info (EERE)

EnergyConnect EnergyConnect Jump to: navigation, search Name EnergyConnect Address 51 East Campbell Avenue, Suite 145 Place Campbell, California Zip 95008 Sector Efficiency Product Demand response system provider/operator Website http://www.energyconnectinc.co Coordinates 37.287725°, -121.948704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.287725,"lon":-121.948704,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

352

Nobel Prize | Other BNL Nobel Proze Connections  

NLE Websites -- All DOE Office Websites (Extended Search)

Other BNL Nobel Prize Connections Other BNL Nobel Prize Connections 2008: Crystal Structure of Green Fluorescent Protein Roger Y. Tsien, University of California, San Diego, Nobel Prize in Chemistry Green fluorescent protein (GFP), which glows green under ultraviolet light, has become a ubiquitous tool in bioscience. It turns out that the structure of GFP was first solved with the help of x-ray studies at Brookhaven's National Synchrotron Light Source. Tsien was an author on that seminal paper. 2004: Studies of the "Strong" Force Frank Wilczek, Massachusetts Institute of Technology, Nobel Prize in Physics Wilcek's work as a theoretical physicist brought him to Brookhaven Lab several times. His first connection with the lab began in 1976, when he worked as an assistant visiting physicist from June to July. He returned in

353

A Connection between Gravitation and Electromagnetism  

E-Print Network (OSTI)

It is argued that there is a connection between the fundamental forces of electromagnetism and gravitation. This connection occurs because of: 1) the fundamental significance of the finite and invariant velocity of light in inertial reference frames in the special theory, and 2) the reliance of the general theory of relativity upon the special theory of relativity locally in spacetime. The connection between the fundamental forces of electromagnetism and gravitation follows immediately from these two points. A brief review is provided of: 1) the role of the finite and invariant velocity of light in inertial reference frames in the special theory, and 2) certain fundamental concepts of the general theory, including its reliance on the special theory locally.

D. M. Snyder

2000-02-16T23:59:59.000Z

354

High-voltage supply for neutron tubes in well-logging applications  

DOE Patents (OSTI)

A high voltage supply is provided for a neutron tube used in well logging. The biased pulse supply of the invention combines DC and full pulse techniques and produces a target voltage comprising a substantial negative DC bias component on which is superimposed a pulse whose negative peak provides the desired negative voltage level for the neutron tube. The target voltage is preferably generated using voltage doubling techniques and employing a voltage source which generates bipolar pulse pairs having an amplitude corresponding to the DC bias level.

Humphreys, D.R.

1982-09-15T23:59:59.000Z

355

Elevated temperature testing of gaskets for bolted flanged connections  

SciTech Connect

Bolted flanged connections are especially prone to leakage when operating at elevated temperatures. In 1986--87, the API Subcommittee on Pressure Vessels, Piping and Tanks expressed a need for gasket performance data and technical formulations to permit the design of gasket systems for high temperature service. The objective was to gain initial understanding of flange behavior, gasket deformation and leakage behavior under simulated elevated temperature service conditions. Experience gained through the previous PVRC-funded elevated temperature test programs as well as companion non-PVRC-funded programs has raised a number of basic questions which would be best answered in the context of a PVRC-supported effort. This Report summarizes the results obtained for four different topics covered in PVRC Grant No. 90-1, namely: (A) verify experimentally the extrapolated long term elevated temperature good performance of compressed asbestos reinforced sheet materials on which are based the MTI guidelines; (B) study the effect of creep/relaxation of flexible graphite sheet materials at elevated temperature on the tightness of a joint in which the gasket deflection remains practically constant; (C) study the effect of the gas medium and pressure on the tightness performance at elevated temperature of graphite filled spiral wound gaskets with and without internal rings; (D) establish correlations between the weight loss of elastomer sheet gasket materials during aging at elevated temperature, and changes in their mechanical properties (tensile strength and relaxation) as well as the variations of their tightness performance.

Derenne, M.; Marchand, L.; Bazergui, A. (Univ. of Montreal, Quebec (Canada). Ecole Polytechnique); Payne, J.R. (J. Payne Associates, Long Valley, NJ (United States))

1994-05-01T23:59:59.000Z

356

Honeywell Parallon Grid-connect Tests Honeywell Grid-connect Tests  

E-Print Network (OSTI)

Appendix C Honeywell Parallon Grid-connect Tests 12/20/2000 #12;Honeywell Grid-connect Tests 12 power Engine Speed Figure C-1: Ramp Down Tests ­ Power and Shaft Speed ­ 15 kW Steps #12;Honeywell Grid Figure C-2: Ramp Down Tests ­ Power and Turbine Exit Temperature ­ 15 kW Steps #12;Honeywell Grid

357

Time series power flow analysis for distribution connected PV generation.  

SciTech Connect

Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating potential PV impacts.

Broderick, Robert Joseph; Quiroz, Jimmy Edward; Ellis, Abraham; Reno, Matthew J. [Georgia Institute of Technology, Atlanta, GA; Smith, Jeff [Electric Power Research Institute, Knoxville, TN; Dugan, Roger [Electric Power Research Institute, Knoxville, TN

2013-01-01T23:59:59.000Z

358

Guidelines for Working at Voltages < 240 Volts  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidelines for Working at Voltages < 240 Volts Guidelines for Working at Voltages < 240 Volts February 4, 2005---DRAFT NOTE: Working hot is a LAST ALTERNATIVE. Electrical hot work is defined as: Working on or near exposed conducting parts that are or might become energized at 50V or more. Refer to Electrical Safety Flowchart for Working On or Near Live Parts. Engineered methods to prevent exposed sources of 50V and greater are to be implemented wherever practical. Only QUALIFIED PERSONNEL {as defined in NFPA 70E Article 110.6(D) 2004 edition} as authorized by the CAT/supervisor/division can perform such work. Refer to Qualified Electrical Worker Flow Chart. Training requirements: ES&H 114 (LOTO) / ES&H 375 (NFPA 70E) / ES&H 371 (electrical worker) - Observe Electrical Safe Work Practices. Refer to

359

Optimal Distributed Voltage Regulation in Power Distribution Networks  

E-Print Network (OSTI)

In this paper, we address the problem of voltage regulation in power distribution networks with deep-penetration of distributed energy resources (DERs), e.g., renewable-based generation, and storage-capable loads such as plug-in hybrid electric vehicles. We cast the problem as an optimization program, where the objective is to minimize the losses in the network subject to constraints on bus voltage magnitudes, limits on active and reactive power injections, transmission line thermal limits and losses. We provide sufficient conditions under which the optimization problem can be solved via its convex relaxation. Using data from existing networks, we show that the conditions are expected to be satisfied by most networks. We also provide an efficient distributed algorithm to solve the problem. The algorithm is asynchronous, with a communication topology that is the same as the electrical network topology. We illustrate the algorithm's performance in the IEEE 34-bus and the 123-bus feeder test systems.

Lam, Albert Y S; Dominguez-Garcia, Alejandro; Tse, David

2012-01-01T23:59:59.000Z

360

Analysis of Lightning-induced Voltages in Overhead Transmission Lines  

Science Journals Connector (OSTI)

Abstract In this work we study the coupling of lightning induced voltages in Overhead Transmission Lines .The study is led directly in the time domain with hold in account the effect of a finite conductivity of the soil. After discretization by the method so-called FDTD (Finite Difference Time Domain) of the lines equations excited by a lightning wave and the application in every node of the network in current and voltage, we deduct a equations system, of which the resolution permits us to deduct the induced electric quantities in every node of the network. In order to confirm our theoretical work, we present a set of applications that allows validating this study.

Mostefa. Boumaiza; Djamel. Labed

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

EnergyConnect Inc | Open Energy Information  

Open Energy Info (EERE)

EnergyConnect Inc EnergyConnect Inc Jump to: navigation, search Name EnergyConnect Inc Place Campbell, California Zip 95008 Sector Services Product EnergyConnect delivers Smart Demand Response technologies and services to commercial, educational, municipal and industrial consumers enabling them to better manage their use of electricity in response to market prices or regional power shortages. Coordinates 33.14919°, -95.951444° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":33.14919,"lon":-95.951444,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

362

Graph-Theoretic Connectivity Control of Mobile  

E-Print Network (OSTI)

exploration, surveillance, and recon- naissance, to cooperative construction and manipulation. The success]­[23]. This research has given rise to connectivity or topology control algorithms that regulate the transmission power is with the Department of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA (e

Pappas, George J.

363

EUROMED SUSTAINABLE CONNECTIONS ANNA LINDH FOUNDATION  

E-Print Network (OSTI)

EUROMED SUSTAINABLE CONNECTIONS ANNA LINDH FOUNDATION BUSINESS ANALYSIS 5:1. EVALUATING FRANCE, UK for export decision making purposes. Definitions and analysis Sustainable development supports meeting human of sustainable development that is; development that "meets the needs of the present without compromising

Zaferatos, Nicholas C.

364

Gout and Genius: A Chemical Connection?  

Science Journals Connector (OSTI)

Gout and Genius: A Chemical Connection? ... That gout and genius are associated is an idea that has surfaced a number of times in the past. ... The author is looking for a common thread that is not limited to I.Q., among those who suffer from gout. ...

Irving M. Klotz

1994-01-01T23:59:59.000Z

365

Connected Vehicle Safety Science, System, and Framework  

E-Print Network (OSTI)

Yi-Ping Hung Intel-NTU Connected Context Computing Center National Taiwan University Taipei, Taiwan 1 kuanwenchen@ntu.edu.tw, 2 hsinmu@csie.ntu.edu.tw, 3 hung@csie.ntu.edu.tw Abstract--In this paper, we propose be effectively prevented. In this paper, we present the challenges arise from realizing intelligent transports

Ouhyoung, Ming

366

Connected obstructions to full graph homomorphisms  

Science Journals Connector (OSTI)

Minimal obstructions to full homomorphisms to a graph B have been proved to be of size at most |B|+1. This turns out to require that disconnected obstructions be allowed. In this paper we prove that the size of minimal connected obstructions is at most ...

Pavol Hell, Aleš Pultr

2014-10-01T23:59:59.000Z

367

Energy-Efficient Connected-Coverage in  

E-Print Network (OSTI)

consume energy, therefore efficient power manage- ment can extend network lifetime. In this paper we Enterprises Ltd. 1 #12;a great impact on prolonging the network lifetime. Power saving techniques canEnergy-Efficient Connected-Coverage in Wireless Sensor Networks Ionut Cardei and Mihaela Cardei

Cardei, Mihaela

368

The Transportation Land Use Connection Bibliography  

E-Print Network (OSTI)

. Boarnet, Reid Ewing, and Richard E. Killingsworth. 2002. "How the Built Environment Affects Physical. "Smart Growth and the Transportation ­ Land Use Connection: What Does the Research Tell Us?" Prepared Button, eds., Handbook 4: Transport and the Environment. Forthcoming. Heilbrun, James. 1987. Urban

Handy, Susan L.

369

Pratt School of Engineering Bass Connections Summary  

E-Print Network (OSTI)

Development Computing and Visualizing the Life of Things: The Museum Inside Out and Visualizing Venice Energy Engineering (1 member) Civil & Environmental Engineering (3 members) Bass Connections themes (5) Energy (12 Processing and Live Art: Performance and Technology Modeling Tools for Energy Systems Analysis (MOTESA

Ferrari, Silvia

370

Distribution capacitor automation that controls voltage and saves energy  

SciTech Connect

The Electric Distribution Business Line of Southern California Edison Company (SCE) has begun a program to improve the distribution system operations and electrical efficiency. The program, called the Distribution System Efficiency Enhancement Program (DSEEP), consists of five principal projects: Automated Switching, Circuit Lock-Out Alarming, Substation Monitoring and Control, Outage Management, and Distribution Capacitor Automation Project (DCAP). DCAP is the largest and most sophisticated of the projects being implemented. The project takes advantage of fine-tuning customer voltages for conservation voltage regulation (CVR) benefits as well as minimizes line losses by reducing unnecessary reactive power flow. DCAP can also help to increase transmission line and substation capacity by improving system power factor. The DCAP system takes advantage of the distributed processing capability of meters, capacitor controllers, radios, and substation processors. DCAP uses two-way packet radios and new electronic meters that read real-time customer voltages as well as energy consumption. The radios transmit customer meter voltage information and capacitor status to substation processors, where a control algorithm runs to determine which capacitors should be turned on or off. The objective of DCAP is to reduce over-all net energy transfer from the substation to the customer and meet system VAR requirements. SCE has tested the system on 66 circuit capacitors (including 3 substation capacitors) on 18 circuits served from two substations. The positive results of the DCAP demonstrations has led to an aggressive roll-out plan for system-wide implementation of automating over 7600 switched capacitors by year-end 1995.

Williams, B.R.

1994-12-31T23:59:59.000Z

371

Archive Reference Buildings by Building Type: Medium office | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Medium office Medium office Archive Reference Buildings by Building Type: Medium office Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available. You can download ZIP files that contain the following: An EnergyPlus software input file (.idf) An html file showing the results from the EnergyPlus simulation (.html) A spreadsheet that summarizes the inputs and results for each location (.xls) The EnergyPlus TMY2 weather file (.epw). benchmark-v1.0_3.0-medium_office.zip benchmark-v1.1_3.1-medium_office.zip benchmark-new-v1.2_4.0-medium_office.zip More Documents & Publications Archive Reference Buildings by Building Type: Large office

372

Real time voltage control using emergency demand response in distribution system by integrating advanced metering infrastructure  

Science Journals Connector (OSTI)

In this paper an analytical study is reported to demonstrate the effects of demand response on distribution network voltages profile. Also a new approach for real time voltage control is proposed which uses emergency demand response program aiming at maintaining voltage profile in an acceptable range with minimum cost. This approach will be active in emergency conditions where in real time the voltages in some nodes leave their permissible ranges. These emergency conditions are Distributed Generation (DG) units and lines outage and unpredictable demand and renewable generations' fluctuations. The proposed approach does not need the load and renewable generation forecast data to regulate voltage. To verify the effectiveness and robustness of the proposed control scheme the proposed voltage control scheme is tested on a typical distribution network. The simulation results show the effectiveness and capability of the proposed real time voltage control model to maintain smart distribution network voltage in specified ranges in both normal and emergency conditions.

Alireza Zakariazadeh; Shahram Jadid

2014-01-01T23:59:59.000Z

373

Demand Response by Decentralized Device Control Based on Voltage Level  

Science Journals Connector (OSTI)

This paper introduces a distributed, self-organizing approach to load control based on voltage measurement. A local voltage measurement defines a Level of Service (LoS), which is balanced with the neighboring ...

Wilfried Elmenreich; Stefan Schuster

2014-01-01T23:59:59.000Z

374

Demand Side Management using VOLTAGE / DISTRIBUTION OPTIMIZATION Quality improvement & Peak reduction  

Science Journals Connector (OSTI)

In order to improve the quality of the electrical energy delivered at consumer households a Voltage Optimization Device (VOD) is introduced in each household. This device controls the output voltage accurately at...

N. H. M. Hofmeester; C. J. van de Water

1994-01-01T23:59:59.000Z

375

E-Print Network 3.0 - ac voltage standard Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

"volts, AC"), the "secondary" voltage is roughly 6 VAC. We shall use the "Universal Transformer... :" conversion of AC to DC You can use a diode to convert the AC voltage of the...

376

E-Print Network 3.0 - applied voltages ii Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

dc-link voltage error is applied to the fun... --In this paper, a new hybrid active power filter topology is presented. A higher-voltage, low-switching fre... - quency...

377

Advanced Gate Drive for the SNS High Voltage Converter Modulator  

SciTech Connect

SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

378

Linear inductive voltage adders (IVA) for advanced hydrodynamic radiography  

SciTech Connect

The electron beam which drifts through the multiple cavities of conventional induction linacs (LIA) is replaced in an IVA by a cylindrical metal conductor which extends along the entire length of the device and effectuates the addition of the accelerator cavity voltages. In the approach to radiography, the linear inductive voltage adder drives a magnetically immersed electron diode with a millimeter diameter cathode electrode and a planar anode/bremsstrahlung converter. Both anode and cathode electrodes are immersed in a strong (15--50 T) solenoidal magnetic field. The electron beam cross section is approximately of the same size as the cathode needle and generates a similar size, very intense x-ray beam when it strikes the anode converter. An IVA driven diode can produce electron beams of equal size and energy as a LIA but with much higher currents (40--50 kA versus 4--5 kA), simpler hardware and thus lower cost. The authors present here first experimental validations of the technology utilizing HERMES 3 and SABRE IVA accelerators. The electron beam voltage and current were respectively of the order of 10 MV and 40 kA. X-ray doses of up to 1 kR {at} 1 m and spot sizes as small as 1.7 mm (at 200 R doses) were measured.

Mazarakis, M.G.; Boyes, J.D.; Johnson, D.L. [and others

1998-09-01T23:59:59.000Z

379

Thermally-induced voltage alteration for integrated circuit analysis  

DOE Patents (OSTI)

A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.

Cole, Jr., Edward I. (Albuquerque, NM)

2000-01-01T23:59:59.000Z

380

Information Commons Help Desk Internet / Connectivity Wireless Access  

E-Print Network (OSTI)

Information Commons Help Desk Internet / Connectivity » Wireless Access ID #1912 Connecting in the Username and Password fields.5. Info Commons Help Desk - Connecting to the UofT wireless netwo... http://help on this entry Info Commons Help Desk - Connecting to the UofT wireless netwo... http://help

Boonstra, Rudy

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

An Open Question about Dependency of Life Time of Hardware Components and Dynamic Voltage Scaling  

E-Print Network (OSTI)

Open question about Dependency of Life Time of Hardware Components and Dynamic Voltage Scaling (A primary idea)

Jaberi, Nasrin

2012-01-01T23:59:59.000Z

382

Limiting discharge voltage of a capacitive energy store in a subway car  

Science Journals Connector (OSTI)

A method is proposed for calculating the limiting discharge voltage of a capacitive energy store in a subway car.

G. G. Ryabtsev; I. A. Ermakov

2012-12-01T23:59:59.000Z

383

Radio-Frequency Interference (RFI) From Extra-High-Voltage (EHV) Transmission Lines  

E-Print Network (OSTI)

discharges are a design issue. Extra-high-voltage (EHV) transmission lines have operating voltages of 345 kV building a 345-kV transmission line from Red Hill, NM to Deming, NM which would run east along US60 to its with respect to radio noise: (1) lines with voltages below 70 kV and (2) lines with voltages above 110 kV

Ellingson, Steven W.

384

Plug-In Hybrid Electric Medium Duty Commercial Fleet Demonstration...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

rravt068vssmiyasato2011o .pdf More Documents & Publications SCAQMD:Plug-In Hybrid Electric Medium-Duty Commercial Fleet Demonstration and Evaluation Plug-In Hybrid Electric...

385

Guidelines and Toolkits for Urban Transport Development in Medium...  

Open Energy Info (EERE)

practitioners in states and municipal governments who are concerned with urban transport development in medium-sized cities in India. In addition, officials within the central...

386

Radiation pressure of light in a refractive medium  

Science Journals Connector (OSTI)

The radiation pressure and energy density of light in a refractive medium is calculated in terms of the index of refraction of the medium. The factor equal to the cube of the index of refraction that occurs in the expressions for the energy density and pressure of light in a refractive medium is shown to arise from the basic thermodynamic nature of the photon system and from the volume dependence of the index of refraction. It is shown that a mechanical pressure exists in a refractive medium which is in equilibrium with the blackbody radiation of the vacuum.

Richard A. Weiss

1976-01-01T23:59:59.000Z

387

Missing Thermal Energy of the Intracluster Medium  

E-Print Network (OSTI)

The Sunyaev-Zel'dovich (SZ) effect is a direct probe of thermal energy content of the Universe, induced in the cosmic microwave background (CMB) sky through scattering of CMB photons off hot electrons in the intracluster medium (ICM). We report a 9-sigma detection of the SZ signal in the CMB maps of Wilkinson Microwave Anisotropy Probe (WMAP) 3yr data, through study of a sample of 193 massive galaxy clusters with observed X-ray temperatures greater than 3 keV. For the first time, we make a model-independent measurement of the pressure profile in the outskirts of the ICM, and show that it closely follows the profiles obtained by X-ray observations and numerical simulations. We find that our measurements of the SZ effect would account for only half of the thermal energy of the cluster, if all the cluster baryons were in the hot ICM phase. Our measurements indicate that a significant fraction (35 +/- 8 %) of baryonic mass is missing from the hot ICM, and thus must have cooled to form galaxies, intracluster stars, or an unknown cold phase of the ICM. There does not seem to be enough mass in the form of stars or cold gas in the cluster galaxies or intracluster space, signaling the need for a yet-unknown baryonic component (at 3-sigma level), or otherwise new astrophysical processes in the ICM.

Niayesh Afshordi; Yen-Ting Lin; Daisuke Nagai; Alastair J. R. Sanderson

2006-12-26T23:59:59.000Z

388

Supernovae Driven Turbulence In The Interstellar Medium  

E-Print Network (OSTI)

I model the multi-phase interstellar medium (ISM) randomly heated and shocked by supernovae, with gravity, differential rotation and other parameters we understand to be typical of the solar neighbourhood. The simulations are 3D extending horizontally 1 x 1 kpc squared and vertically 2 kpc, symmetric about the galactic mid-plane. They routinely span gas number densities 1/10000 to 100 per cubic cm, temperatures 100 to 100 MK, speeds up to 10000 km/s and Mach number up to 25. Radiative cooling is applied from two widely adopted parameterizations, and compared directly to assess the sensitivity of the results to cooling. There is strong evidence to describe the ISM as comprising well defined cold, warm and hot regions, which are statistically close to thermal and total pressure equilibrium. This result is not sensitive to the choice of parameters considered here. The distribution of the gas density within each can be robustly modelled as lognormal. Appropriate distinction is required between the properties of t...

Gent, Frederick

2014-01-01T23:59:59.000Z

389

Topology optimization-based distribution design of actuation voltage in static shape control of plates  

Science Journals Connector (OSTI)

This paper investigates the optimal spatial distribution of single-channel actuation voltage in static structural shape control problem. It is pointed out that single-channel actuation voltage input for shape control applications is of practical importance ... Keywords: Shape control, Single channel, Topology optimization, Voltage distribution

Zhan Kang; Liyong Tong

2008-10-01T23:59:59.000Z

390

Impact of Wind Generation Variability on Voltage Profile of Radial Power Systems  

Science Journals Connector (OSTI)

This paper provides the results of a study conducted to assess the impacts of the "wind generation variability" on the voltage profile in a small-scale radial power system. The power network has been modeled using one of the well-known simulation programs ... Keywords: Wind Generation, Voltage Profile, Power Grids, Voltage Impacts, Minimum Singular Value, SSV index

M. O. Alruwaili; M. Y. Vaziri; S. Vadhva; S. Vaziri

2013-04-01T23:59:59.000Z

391

Statistical Estimation of Leakage-Induced Power Grid Voltage Drop Considering Within-Die Process Variations  

E-Print Network (OSTI)

Statistical Estimation of Leakage-Induced Power Grid Voltage Drop Considering Within-Die Process the power grid, the grid develops large voltage drops, which is an unavoidable background level of noise on the grid. We develop techniques for estimation of the statistics of the leakage-induced power grid voltage

Najm, Farid N.

392

Statistical Estimation of LeakageInduced Power Grid Voltage Drop Considering WithinDie Process Variations #  

E-Print Network (OSTI)

Statistical Estimation of Leakage­Induced Power Grid Voltage Drop Considering Within­Die Process the power grid, the grid develops large voltage drops, which is an unavoidable background level of noise on the grid. We develop techniques for estimation of the statistics of the leakage­induced power grid voltage

Najm, Farid N.

393

Statistical Estimation of Circuit Timing Vulnerability Due to Leakage-Induced Power Grid Voltage Drop  

E-Print Network (OSTI)

Statistical Estimation of Circuit Timing Vulnerability Due to Leakage-Induced Power Grid Voltage voltage drops on the power grid that can affect circuit timing. We propose a statistical analysis supply voltage to circuit devices is referred to as the power grid. The consequences of power grid

Najm, Farid N.

394

Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines  

E-Print Network (OSTI)

Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines: State-of-the-Art Review deals with low-voltage ride-through (LVRT) capability of wind turbines (WTs) and in particular those as to index some emerging solutions. Index Terms--Wind turbine, doubly-fed induction generator, low voltage

Paris-Sud XI, Université de

395

Research on fuzzy logic based dynamic boundary voltage and reactive power integrated control method  

Science Journals Connector (OSTI)

Aiming at the existing problems of conventional substation voltage and reactive power integrated control method, a new fuzzy logic based dynamic reactive power boundary voltage and reactive power integrated control method is proposed. Fuzzy logic control ... Keywords: dynamic boundary, fuzzy logic, reactive power, voltage

Zigang Xu; Fei Wang

2009-06-01T23:59:59.000Z

396

DSP IMPLEMENTATION OF DC VOLTAGE REGULATION USING ADAPTIVE CONTROL FOR 200 KW 62000 RPM  

E-Print Network (OSTI)

to control the DC voltage for 200 kW induction generator rated at a speed of 62000 RPM under different load to regulate the DC voltage for high speed induction generators rated from 5 kW to 200 kW. ii #12DSP IMPLEMENTATION OF DC VOLTAGE REGULATION USING ADAPTIVE CONTROL FOR 200 KW 62000 RPM INDUCTION

Wu, Thomas

397

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares in the  

E-Print Network (OSTI)

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares high-voltage transformer spares throughout the electric grid to mitigate the risk of random transformer-voltage transformers are an integral part of the electric transmission system. A catas- trophic transformer failure

Powell, Warren B.

398

Application-Directed Voltage Scaling Johan Pouwelse, Koen Langendoen, and Henk Sips  

E-Print Network (OSTI)

--Clock (and voltage) scheduling is an important tech- nique to reduce the energy consumption of processors that sup- port voltage scaling. It is difficult, however, to achieve good re- sults using only statistics to the scheduler control- ling the clock speed and processor voltage. This paper describes our Energy Priority

Pouwelse, Johan

399

Connecting to MySQL from PHP $link = mysql_connect($hostname, $username, $password)  

E-Print Network (OSTI)

Connecting to MySQL from PHP ;Array handling in PHP In PHP, arrays are associative. Any number or string can be used to index an array the variable $result. #12;HTML forms and PHP variables php" METHOD="GET">

Elkan, Charles

400

The Barbero connection and its relation to the histories connection formalism without gauge fixing  

E-Print Network (OSTI)

We present a histories version of the connection formalism of general relativity. Such an approach introduces a spacetime description--a characteristic feature of the histories approach--and we discuss the extent to which the usual loop variables are compatible with a spacetime description. In particular, we discuss the definability of the Barbero connection without any gauge fixing. Although it is not the pullback of a spacetime connection onto the three-surface and it does not have a natural spacetime interpretation, this does not mean that the Barbero connection is not suitable variable for quantisation; it appears naturally in the formalism even in absence of gauge fixing. It may be employed therefore, to define loop variables similar to those employed in loop quantum gravity. However, the loop algebra would have to be augmented by the introduction of additional variables.

Ntina Savvidou

2006-02-07T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

EnergyConnect (Oregon) | Open Energy Information  

Open Energy Info (EERE)

EnergyConnect EnergyConnect Address 5335 SW Meadows Road, Suite 325 Place Lake Oswego, Oregon Zip 97035 Sector Efficiency Product Demand response system provider/operator Website http://www.energyconnectinc.co Coordinates 45.4183°, -122.733247° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":45.4183,"lon":-122.733247,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

402

EnergyConnect (Pennsylvania) | Open Energy Information  

Open Energy Info (EERE)

EnergyConnect EnergyConnect Address 1 West First Ave Suite 100 Place Conshohocken, Pennsylvania Zip 19428 Sector Efficiency Product Demand response system provider/operator Website http://www.energyconnectinc.co Coordinates 40.073997°, -75.307096° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.073997,"lon":-75.307096,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

403

Mechanical connection for a tubular assembly  

DOE Patents (OSTI)

Disclosed is a mechanical connection assembly for connecting two telescopically related parts together in a fluidtight relation. The system uses snap-in fasteners having flexible barbed tangs which are snapped into receiving holes formed in the parts being attached together. A locking pin can be inserted into a central aperture through the snap-in fastener to secure the fastener in the receiving holes. The system also includes a seal having sealing surfaces at least one of which is formed at an angle inclined relative to a true vertical. a metallic sealing element is interposed between the sealing surfaces. The geometry of the sealing surfaces is capable of compensating for the differential thermal growth rates occurring when the two parts are made from dissimilar metals.

Grover, J.M.

1984-09-12T23:59:59.000Z

404

Optical quantum swapping in a coherent atomic medium  

E-Print Network (OSTI)

We propose to realize a passive optical quantum swapping device which allows for the exchange of the quantum fluctuations of two bright optical fields interacting with a coherent atomic medium in an optical cavity. The device is based on a quantum interference process between the fields within the cavity bandwidth arising from coherent population trapping in the atomic medium.

Aurelien Dantan

2011-10-03T23:59:59.000Z

405

Three-Phase Modular Cascaded H-Bridge Multilevel Inverter with Individual MPPT for Grid-Connected Photovoltaic Systems  

SciTech Connect

A three-phase modular cascaded H-bridge multilevel inverter for a grid-connected photovoltaic (PV) system is presented in this paper. To maximize the solar energy extraction of each PV string, an individual maximum power point tracking (MPPT) control scheme is applied, which allows the independent control of each dc-link voltage. PV mismatches may introduce unbalanced power supplied to the three-phase system. To solve this issue, a control scheme with modulation compensation is proposed. The three-phase modular cascaded multilevel inverter prototype has been built. Each H-bridge is connected to a 185 W solar panel. Simulation and experimental results are presented to validate the proposed ideas.

Xiao, Bailu [ORNL; Hang, Lijun [ORNL; Riley, Cameron [University of Tennessee, Knoxville (UTK); Tolbert, Leon M [ORNL; Ozpineci, Burak [ORNL

2013-01-01T23:59:59.000Z

406

The Application of Droop-Control in Distributed Energy Resources to Extend the Voltage Collapse Margin  

SciTech Connect

The growth in distributed energy resources has the potential to reduce system stresses caused by transmission grid congestion by supplying power and voltage regulation closer to load centers. However, the additional voltage regulation provided by these resources can mask the onset of voltage collapse. Local voltage support flattens the slope in the upper region of the power-voltage nose curve. Coordinating voltage-regulation behavior with the droop-control scheme in distributed resources improves the observation of voltage collapse margins. Incorporating distributed resource models in the continuation power flow analysis, allows the exploration of the power transfer gains by the application of distributed resources. The analysis provides insight to the impact of droop control on the behavior of the power-voltage curve and voltage collapse. The analysis is applied to a fixed speed induction generator wind farm with separate reactive compensation and the interconnection to the local power system. Results reveal that coordinating the droop control strategy allows the distributed resource to significantly increase the voltage collapse margin without hiding the threat of voltage stability problems.

Henry, Shawn D. [Florida State University; Rizy, D Tom [ORNL; Baldwin, Thomas L [Florida State University; Kueck, John D [ORNL; Li, Fangxing [ORNL

2008-01-01T23:59:59.000Z

407

High-voltage R-F feedthrough bushing  

DOE Patents (OSTI)

Described is a multi-element, high voltage radio frequency bushing for transmitting rf energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.

Grotz, G.F.

1982-09-03T23:59:59.000Z

408

Outdoor PV Module Degradation of Current-Voltage Parameters: Preprint  

SciTech Connect

Photovoltaic (PV) module degradation rate analysis quantifies the loss of PV power output over time and is useful for estimating the impact of degradation on the cost of energy. An understanding of the degradation of all current-voltage (I-V) parameters helps to determine the cause of the degradation and also gives useful information for the design of the system. This study reports on data collected from 12 distinct mono- and poly-crystalline modules deployed at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. Most modules investigated showed < 0.5%/year decrease in maximum power due to short-circuit current decline.

Smith, R. M.; Jordan, D. C.; Kurtz, S. R.

2012-04-01T23:59:59.000Z

409

Self-monitoring high voltage transmission line suspension insulator  

DOE Patents (OSTI)

A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

Stemler, Gary E. (Vancouver, WA); Scott, Donald N. (Vancouver, WA)

1981-01-01T23:59:59.000Z

410

Voltage sensor with fiber Fabry-Perot interferometer  

E-Print Network (OSTI)

with smaller strain constants, a larger voltage must be applied to get a 2x round trip phase shift. Hence, a longer FFPI is needed to get higher resolution. 16 A plate type PZT was selected because it's more convenient to attach to a thermo-electric cooler... in electron-beam evaporation system, they can be spliced to uncoated fibers, which also have cleaved end surfaces. The basic configuration for this Siecor Model M 67 fusion splicer is shown in fig. 12. A electric arc is initiated between the electrodes...

Wann, Been-Huey

1992-01-01T23:59:59.000Z

411

Open bottom mesons in hot asymmetric hadronic medium  

E-Print Network (OSTI)

The in-medium masses and optical potentials of $B$ and ${\\bar B}$ mesons are studied in an isospin asymmetric, strange, hot and dense hadronic environment using a chiral effective model. The chiral $SU(3)$ model originally designed for the light quark sector, is generalized to include the heavy quark sector ($c$ and $b$) to derive the interactions of the $B$ and $\\bar B$ mesons with the light hadrons. Due to large mass of bottom quark, we use only the empirical form of these interactions for the desired purpose, while treating the bottom degrees of freedom to be frozen in the medium. Hence, all medium effects are due to the in-medium interaction of the light quark content of these open-bottom mesons. Both $B$ and $\\bar B$ mesons are found to experience net attractive interactions in the medium, leading to lowering of their masses in the medium. The mass degeneracy of particles and antiparticles, ($B^+$, $B^-$) as well as ($B^0$, ${\\bar B}^0$), is observed to be broken in the medium, due to equal and opposite contributions from a vectorial Weinberg-Tomozawa interaction term. Addition of hyperons to the medium lowers further the in-medium mass for each of these four mesons, while a non-zero isospin asymmetry is observed to break the approximate mass degeneracy of each pair of isospin doublets. These medium effects are found to be strongly density dependent, and bear a considerably weaker temperature dependence. The results obtained in the present investigation are compared to predictions from the quark-meson coupling model, heavy meson effective theory, and the QCD Sum Rule approach.

Divakar Pathak; Amruta Mishra

2014-09-02T23:59:59.000Z

412

Stabilisation of grid connected wind farms using doubly-fed induction generators with FACTS controllers  

Science Journals Connector (OSTI)

The impact of the wind generation on the power systems is no longer negligible if high penetration levels are going to be achieved. It is very important to boost the transfer capability of the transmission system while improving the utilisation of transmission assets to accommodate high penetration of wind power on the network. Hence, more sophisticated control schemes using advanced power electronic-based flexible AC transmission system (FACTS) controllers are required which will enhance voltage security and voltage stability control. This paper presents the impact of FACTS controllers on the dynamic stability of power systems connected with wind energy conversion systems. The wind farm model considered is a variable speed doubly-fed induction generator model. The dynamic simulation results yield information on: 1) the impact of faults and wind speed changes on the performance of DFIG-based induction generators; 2) the change in controllable parameters of the FACTS controllers following the faults and wind speed changes; 3) transient rating of the FACTS controllers for enhancement of rotor speed stability of induction generators and angle stability of synchronous generators.

N. Senthil Kumar

2013-01-01T23:59:59.000Z

413

Realization and control of a wind turbine connected to the grid by using PMSG  

Science Journals Connector (OSTI)

Abstract This paper studies the control of a variable-speed wind turbine using the permanent magnet synchronous generator (PMSG) driven by a wind turbine emulator. The wind turbine is realized by imposing the wind profile on emulator to behave as the real wind turbine when it receives the same wind profile. This wind turbine is connected to the grid by means of a two back-to-back voltage-fed pulse width-modulation (PWM) converters to interface the generator and the grid. This paper has three main objectives, the first is realization of the wind turbine emulator, the second is extracting and exploiting the maximum power from the wind, the third is feeding the grid by high-power and good electrical energy quality; to achieve that, we applied the strategies of maximum power point tracking (MPPT) using optimal torque control which allows the PMSG to operate at an optimal speed. The inverter is used for delivering power to the grid, controlled in a way to deliver only the active power into the grid, thus we have unit power factor. DC-link voltage is also controlled by the inverter. This paper shows the dynamic performances of the complete system by its simulation using Matlab Simulink. Experimental results has verified and validated the wind turbine emulator and the efficiency of MPPT control method using a variable wind profile.

Abdeldjalil Dahbi; Mabrouk Hachemi; Nasreddine Nait-Said; Mohamed-Said Nait-Said

2014-01-01T23:59:59.000Z

414

Methods, systems and apparatus for controlling third harmonic voltage when operating a multi-space machine in an overmodulation region  

SciTech Connect

Methods, system and apparatus are provided for controlling third harmonic voltages when operating a multi-phase machine in an overmodulation region. The multi-phase machine can be, for example, a five-phase machine in a vector controlled motor drive system that includes a five-phase PWM controlled inverter module that drives the five-phase machine. Techniques for overmodulating a reference voltage vector are provided. For example, when the reference voltage vector is determined to be within the overmodulation region, an angle of the reference voltage vector can be modified to generate a reference voltage overmodulation control angle, and a magnitude of the reference voltage vector can be modified, based on the reference voltage overmodulation control angle, to generate a modified magnitude of the reference voltage vector. By modifying the reference voltage vector, voltage command signals that control a five-phase inverter module can be optimized to increase output voltages generated by the five-phase inverter module.

Perisic, Milun; Kinoshita, Michael H; Ranson, Ray M; Gallegos-Lopez, Gabriel

2014-06-03T23:59:59.000Z

415

Bi-directional power control system for voltage converter  

DOE Patents (OSTI)

A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

Garrigan, Neil Richard (Niskayuna, NY); King, Robert Dean (Schenectady, NY); Schwartz, James Edward (Slingerlands, NY)

1999-01-01T23:59:59.000Z

416

Improving the low voltage ride through of doubly fed induction generator during intermittent voltage source converter faults  

E-Print Network (OSTI)

has the advantages of maximum power capture, less mechanical stresses, and less acoustical noise.4 the connection of the wind turbine during the various studied faults. VC 2013 AIP Publishing LLC. [http://dx.doi.org/10.1063/1.4812651] I. INTRODUCTION Wind energy has become one of the most popular green renewable

Pota, Himanshu Roy

417

Wavelet technique based islanding detection and improved repetitive current control for reliable operation of grid-connected PV systems  

Science Journals Connector (OSTI)

Abstract Recent years have witnessed a thrust towards the use of solar energy as the major renewable energy source for distributed power generation. The proposed system requires reliable detection technique and suitable current control strategy for proper operation. This paper focuses on plug-in repetitive current (RC) control strategy for grid connected inverter system and wavelet technique for electrical grid status identification. The performance of proposed current control technique employed for grid connected inverter system under distorted and unbalanced grid voltage is compared with the existing conventional methods like PI and PR controller. This controller uses the feedback control system for attenuating periodic disturbances, improving high quality sinusoidal output current and high power factor. The proposed scheme employs fourth order infinite impulse response (IIR) filter for maintaining its resonance frequency, output frequency matching with grid fundamental frequency and reduction of harmonics. The DC-DC boost converter implements incremental conductance based (INC) maximum power point tracker (MPPT) algorithm. The effects of LCL filter for improving disturbance rejection capability and dynamic performance of the proposed system is also demonstrated. Grid connected PV inverter employs wavelet technique for an islanding detection functionality in order to determine the status of the electrical grid. In order to show the effectiveness of the proposed algorithm, modeling and simulation for grid connected PV system is performed using MATLAB/SIMULINK and its PowerSim toolbox.

Smitha Joyce Pinto; Gayadhar Panda

2015-01-01T23:59:59.000Z

418

SciTech Connect: enriched uranium  

Office of Scientific and Technical Information (OSTI)

enriched uranium Find enriched uranium Find How should I search Scitech Connect ... Basic or Advanced? Basic Search Advanced Ă— Advanced Search Options Full Text: Bibliographic Data: Creator / Author: Name Name ORCID Title: Subject: Identifier Numbers: Research Org.: Sponsoring Org.: Site: All Alaska Power Administration, Juneau, Alaska (United States) Albany Research Center (ARC), Albany, OR (United States) Albuquerque Complex - NNSA Albuquerque Operations Office, Albuquerque, NM (United States) Amarillo National Resource Center for Plutonium, Amarillo, TX (United States) Ames Laboratory (AMES), Ames, IA (United States) Argonne National Laboratory (ANL), Argonne, IL (United States) Argonne National Laboratory-Advanced Photon Source (United States) Atlanta Regional Office, Atlanta, GA (United States) Atmospheric Radiation Measurement (ARM)

419

Tree Death Study's Climate Change Connections  

SciTech Connect

What are the exact physiological mechanisms that lead to tree death during prolonged drought and rising temperatures? These are the questions that scientists are trying to answer at a Los Alamos National Laboratory research project called SUMO. SUMO stands for SUrvival/MOrtality study; it's a plot of land on the Lab's southern border that features 18 climate controlled tree study chambers and a large drought structure that limits rain and snowfall. Scientists are taking a wide variety of measurements over a long period of time to determine what happens during drought and warming, and what the connections and feedback loops might be between tree death and climate change.

McDowell, Nate

2012-09-10T23:59:59.000Z

420

Tree Death Study's Climate Change Connections  

ScienceCinema (OSTI)

What are the exact physiological mechanisms that lead to tree death during prolonged drought and rising temperatures? These are the questions that scientists are trying to answer at a Los Alamos National Laboratory research project called SUMO. SUMO stands for SUrvival/MOrtality study; it's a plot of land on the Lab's southern border that features 18 climate controlled tree study chambers and a large drought structure that limits rain and snowfall. Scientists are taking a wide variety of measurements over a long period of time to determine what happens during drought and warming, and what the connections and feedback loops might be between tree death and climate change.

McDowell, Nate

2014-06-25T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Grid-Connected Renewable Energy Generation Toolkit-Hydroelectric | Open  

Open Energy Info (EERE)

Grid-Connected Renewable Energy Generation Toolkit-Hydroelectric Grid-Connected Renewable Energy Generation Toolkit-Hydroelectric Jump to: navigation, search Tool Summary Name: Grid-Connected Renewable Energy Generation Toolkit-Hydroelectric Agency/Company /Organization: United States Agency for International Development Sector: Energy Resource Type: Training materials Website: www.energytoolbox.org/gcre/mod_4/index.shtml Grid-Connected Renewable Energy Generation Toolkit-Hydroelectric Screenshot References: Grid-Connected Renewable Energy Generation Toolkit-Hydroelectric[1] Logo: Grid-Connected Renewable Energy Generation Toolkit-Hydroelectric GCREhydro.JPG References ↑ "Grid-Connected Renewable Energy Generation Toolkit-Hydroelectric" Retrieved from "http://en.openei.org/w/index.php?title=Grid-Connected_Renewable_Energy_Generation_Toolkit-Hydroelectric&oldid=375082

422

Maintaining connectivity in a mobile ad hoc network  

E-Print Network (OSTI)

This thesis focuses on the problem of maintaining graphics. connectivity in a mobile ad hoc network. Mobile ad hoc networks are without a fixed topology and are dynamically changing. This makes the problem of maintaining connectivity among all nodes...

Reuben, Ron S.

2012-06-07T23:59:59.000Z

423

Breakout Session: Solar in the Connected Building | Department...  

Office of Environmental Management (EM)

in the Connected Building Breakout Session: Solar in the Connected Building May 21, 2014 5:15PM to 6:15PM PDT Huntington This session will explore the technologies, processes, and...

424

Fretting damage prediction of connecting rod of marine diesel engine  

Science Journals Connector (OSTI)

There is frequent fretting damage at the mating surface of a connecting rod because the connecting rod in a combustion engine is heavily loaded as well as rotated. ... possibility at the planar upper split of the...

Jung Ho Son; Sung Chan Ahn; Jong Gug Bae…

2011-02-01T23:59:59.000Z

425

National High Magnetic Field Laboratory - Series Connected Hybrid  

NLE Websites -- All DOE Office Websites (Extended Search)

Magnet Lab Series Connected Hybrid for Magnet Lab Figure 1. Vertical Section of the Series Connected Hybrid Magnet for the Mag Lab. The Magnet Lab has embarked on innovative...

426

JC3 Medium Impact Assessment Bulletins | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Medium Impact Medium Impact Assessment Bulletins JC3 Medium Impact Assessment Bulletins RSS December 4, 2012 V-039: Samsung and Dell printers Firmware Backdoor Unauthorized Access Vulnerability Samsung has issued a security advisory and an optional firmware update for all current Samsung networked laser printers and multifunction devices to enhance Simple Network Management Protocol (SNMP) security. November 30, 2012 V-037: Wireshark Multiple Bugs Let Remote Users Deny Service Several vulnerabilities were reported in Wireshark. November 29, 2012 V-036: EMC Smarts Network Configuration Manager Database Authentication Bypass Vulnerability Two vulnerabilities were reported in EMC Smarts Network Configuration Manager. November 27, 2012 V-034: RSA Adaptive Authentication (On-Premise) Input Validation Flaws

427

Electromagnetic field quantization in a linear dielectric medium  

E-Print Network (OSTI)

By modeling a dielectric medium with two independent reservoirs, i.e., electric and magnetic reservoirs, the electromagnetic field is quantized in a linear dielectric medium consistently. A Hamiltonian is proposed from which using the Heisenberg equations, not only the Maxwell equations but also the structural equations can be obtained. Using the Laplace transformation, the wave equation for the electromagnetic vector potential is solved in the case of a homogeneous dielectric medium. Some examples are considered showing the applicability of the model to both absorptive and nonabsorptive dielectrics.

F. Kheirandish; M. Amooshahi

2005-11-13T23:59:59.000Z

428

Control of Analyte Electrolysis in Electrospray Ionization Mass Spectrometry Using Repetitively Pulsed High Voltage  

SciTech Connect

Analyte electrolysis using a repetitively pulsed high voltage ion source was investigated and compared to that using a regular, continuously operating direct current high voltage ion source in electrospray ionization mass spectrometry. The extent of analyte electrolysis was explored as a function of the length and frequency of the high voltage pulse using the model compound reserpine in positive ion mode. Using +5 kV as the maximum high voltage amplitude, reserpine was oxidized to its 2, 4, 6 and 8-electron oxidation products when direct current high voltage was employed. In contrast, when using a pulsed high voltage, oxidation of reserpine was eliminated by employing the appropriate high voltage pulse length and frequency. This effect was caused by inefficient mass transport of the analyte to the electrode surface during the duration of the high voltage pulse and the subsequent relaxation of the emitter electrode/ electrolyte interface during the time period when the high voltage was turned off. This mode of ESI source operation allows for analyte electrolysis to be quickly and simply switched on or off electronically via a change in voltage pulse variables.

Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

2011-01-01T23:59:59.000Z

429

Effects of Beamforming on the Connectivity of Ad Hoc Networks  

E-Print Network (OSTI)

Effects of Beamforming on the Connectivity of Ad Hoc Networks Xiangyun Zhou, Haley M. Jones, Salman on the connectivity of wireless ad hoc networks. We study different beamforming techniques using the uniform circular information. Index Terms-- ad hoc networks, antenna arrays, beamforming, connectivity. I. INTRODUCTION Mobile

Zhou, Xiangyun "Sean"

430

Minimum cost connection networks: truth-telling and implementation  

E-Print Network (OSTI)

Minimum cost connection networks: truth-telling and implementation Jens Leth Hougaard Mich Tvede Abstract In the present paper we consider the allocation of costs in connection networks. Agents have are costly to build. The problem is to allocate costs of networks satisfying all connection demands. We use

Guo, Zaoyang

431

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators  

E-Print Network (OSTI)

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators General Description The LM139 series consists of four independent precision voltage comparators with an offset voltage clock timers; multivibrators and high voltage digital logic gates. The LM139 series was designed

Lanterman, Aaron

432

Electromagnetic radiation in a time-varying background medium  

E-Print Network (OSTI)

Analytical solutions are presented for the electromagnetic radiation by an arbitrary pulsed source into a homogeneous time-varying background medium. In the constant-impedance case an explicit radiation formula is obtained for the synchronous permittivity and permeability described by any positive function of time. As might be expected, such a medium introduces significant spectral shifts and spatio-temporal modulation, which are analized here for the linear and exponential time-variations of the medium parameters. In the varying-impedance case the solution is obtained for the fourth-order polynomial time-dependence of the permittivity. In addition to the spectral shifts and modulation this spatially homogeneous medium scatters the field introducing causal echoes at the receiver location.

Budko, Neil V

2009-01-01T23:59:59.000Z

433

Multiphase turbulent interstellar medium: some recent results from radio astronomy  

E-Print Network (OSTI)

The radio frequency 1.4 GHz transition of the atomic hydrogen is one of the important tracers of the diffuse neutral interstellar medium. Radio astronomical observations of this transition, using either a single dish telescope or an array interferometer, reveal different properties of the interstellar medium. Such observations are particularly useful to study the multiphase nature and turbulence in the interstellar gas. Observations with multiple radio telescopes have recently been used to study these two closely related aspects in greater detail. Using various observational techniques, the density and the velocity fluctuations in the Galactic interstellar medium was found to have a Kolmogorov-like power law power spectra. The observed power law scaling of the turbulent velocity dispersion with the length scale can be used to derive the true temperature distribution of the medium. Observations from a large ongoing atomic hydrogen absorption line survey have also been used to study the distribution of gas at d...

Roy, Nirupam

2015-01-01T23:59:59.000Z

434

Georgia Power - Small and Medium Scale Advanced Solar Initiative (GPASI)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Georgia Power - Small and Medium Scale Advanced Solar Initiative Georgia Power - Small and Medium Scale Advanced Solar Initiative (GPASI) (Georgia) Georgia Power - Small and Medium Scale Advanced Solar Initiative (GPASI) (Georgia) < Back Eligibility Agricultural Commercial General Public/Consumer Installer/Contractor Institutional Local Government Multi-Family Residential Nonprofit Residential Schools State Government Savings Category Solar Buying & Making Electricity Program Info Start Date 03/01/2013 State Georgia Program Type Other Incentive Provider GPASI Project Manager '''''Note: The application process for the small and medium scale solar programs began on March 1, 2013 and will continue through March 11, 2013. If completed applications exceed program capacity limit of 45 megawatts (MW), a lottery will be conducted, with Georgia Public Service Commission

435

Local Voltage Support from Distributed Energy Resources to Prevent Air Conditioner Motor Stalling  

SciTech Connect

Microgrid voltage collapse often happens when there is a high percentage of low inertia air-conditioning (AC) motors in the power systems. The stalling of the AC motors results in Fault Induced Delayed Voltage Recovery (FIDVR). A hybrid load model including typical building loads, AC motor loads, and other induction motor loads is built to simulate the motoring stalling phenomena. Furthermore, distributed energy resources (DE) with local voltage support capability are utilized to boost the local bus voltage during a fault, and prevent the motor stalling. The simulation results are presented. The analysis of the simulation results show that local voltage support from multiple DEs can effectively and economically solve the microgrid voltage collapse problem.

Baone, Chaitanya A [ORNL] [ORNL; Xu, Yan [ORNL] [ORNL; Kueck, John D [ORNL] [ORNL

2010-01-01T23:59:59.000Z

436

Bright and fast voltage reporters across the visible spectrum via electrochromic FRET (eFRET)  

E-Print Network (OSTI)

We present a palette of brightly fluorescent genetically encoded voltage indicators (GEVIs) with excitation and emission peaks spanning the visible spectrum, sensitivities from 6 - 10% Delta F/F per 100 mV, and half-maximal response times from 1 - 7 ms. A fluorescent protein is fused to an Archaerhodopsin-derived voltage sensor. Voltage-induced shifts in the absorption spectrum of the rhodopsin lead to voltage-dependent nonradiative quenching of the appended fluorescent protein. Through a library screen, we identified linkers and fluorescent protein combinations which reported neuronal action potentials in cultured rat hippocampal neurons with a single-trial signal-to-noise ratio from 6.6 to 11.6 in a 1 kHz imaging bandwidth at modest illumination intensity. The freedom to choose a voltage indicator from an array of colors facilitates multicolor voltage imaging, as well as combination with other optical reporters and optogenetic actuators.

Zou, Peng; Douglass, Adam D; Hochbaum, Daniel R; Brinks, Daan; Werley, Christopher A; Harrison, D Jed; Campbell, Robert E; Cohen, Adam E

2014-01-01T23:59:59.000Z

437

Seismic vulnerability assessment of a high voltage disconnect switch  

Science Journals Connector (OSTI)

Abstract This paper deals with the seismic vulnerability of high voltage equipment typically installed in electric substations. In particular, the seismic response of a 380 kV vertical disconnect switch has been investigated based on the results of an experimental campaign carried out at Roma Tre University. According to a series of non-linear analyses, the influence of the most significant parameters on the seismic behavior of this apparatus has been analyzed and the corresponding fragility curves have been evaluated by using the Effective Fragility Analysis method. The results showed a limited vulnerability of the disconnect switch, whose most critical parts are the bottom joint of the ceramic support column and the steel column base.

Fabrizio Paolacci; Renato Giannini; Silvia Alessandri; Gianmarco De Felice

2014-01-01T23:59:59.000Z

438

Discriminator based on voltage comparator for nuclear physics research  

SciTech Connect

This paper describes a simple discriminator of low-level pulses with integral discrimination based on a K521SA3 comparator. The discriminator can be used to record pulses with durations of greater than or equal to 0.1 usec and amplitudes of greater than or equal to 1 mV. the input-pulse amplitude must not exceed the supply-voltage amplitude. A schematic diagram of the discriminator is given. For operation of the NGR spectrometer in the constant-velocity mode, the comparator was gated by the bipolar vibrator-velocity signal. The described circuit is reliable under laboratory conditions and its use is promising in multi-input systems such as those with multisection coordinate detectors.

Vorob'ev, V.A.; Kiselev, A.A.; Kuz'min, R.N.

1985-12-01T23:59:59.000Z

439

Effect of DC voltage pulses on memristor behavior.  

SciTech Connect

Current knowledge of memristor behavior is limited to a few physical models of which little comprehensive data collection has taken place. The purpose of this research is to collect data in search of exploitable memristor behavior by designing and implementing tests on a HP Labs Rev2 Memristor Test Board. The results are then graphed in their optimal format for conceptualizing behavioral patterns. This series of experiments has concluded the existence of an additional memristor state affecting the behavior of memristors when pulsed with positively polarized DC voltages. This effect has been observed across multiple memristors and data sets. The following pages outline the process that led to the hypothetical existence and eventual proof of this additional state of memristor behavior.

Evans, Brian R.

2013-10-01T23:59:59.000Z

440

Voltage flicker prediction for two simultaneously operated ac arc furnaces  

SciTech Connect

An EMTP-based arc furnace model was developed for evaluation of flicker concerns associated with supplying a large integrated steel mill as they go from one to two furnace operation and as system changes are implemented that will affect the short circuit capacity at the 230 kV power supply substation. The model includes a dynamic arc representation which is designed to be characteristic of the initial portions of the melt cycle when the arc characteristics are the most variable (worst flicker conditions). The flicker calculations are verified using previous measurements with one furnace operation. Flicker simulations were then performed to evaluate a variety of different possible system strengths with both one and two furnaces in operation. The primary flicker measure used for this study is the unweighted rms value of the fluctuation envelope, expressed as a percentage of the rms line-to-ground voltage magnitude.

Tang, L. [ABB Power T and D Co., Inc., Raleigh, NC (United States)] [ABB Power T and D Co., Inc., Raleigh, NC (United States); Kolluri, S. [Entergy Services, New Orleans, LA (United States)] [Entergy Services, New Orleans, LA (United States); McGranaghan, M.F. [Electrotek Concepts, Inc., Knoxville, TN (United States)] [Electrotek Concepts, Inc., Knoxville, TN (United States)

1997-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Voltage spike detection in high field superconducting accelerator magnets  

SciTech Connect

A measurement system for the detection of small magnetic flux changes in superconducting magnets, which are due to either mechanical motion of the conductor or flux jump, has been developed at Fermilab. These flux changes are detected as small amplitude, short duration voltage spikes, which are {approx}15mV in magnitude and lasts for {approx}30 {micro}sec. The detection system combines an analog circuit for the signal conditioning of two coil segments and a fast data acquisition system for digitizing the results, performing threshold detection, and storing the resultant data. The design of the spike detection system along with the modeling results and noise analysis will be presented. Data from tests of high field Nb{sub 3}Sn magnets at currents up to {approx}20KA will also be shown.

Orris, D.F.; Carcagno, R.; Feher, S.; Makulski, A.; Pischalnikov, Y.M.; /Fermilab

2004-12-01T23:59:59.000Z

442

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents (OSTI)

A process for fabricating sequential inductors and varistor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varistor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process. 6 figs.

Cooper, G.A.

1994-10-04T23:59:59.000Z

443

High-speed, sub-pull-in voltage MEMS switching.  

SciTech Connect

We have proposed and demonstrated MEMS switching devices that take advantage of the dynamic behavior of the MEMS devices to provide lower voltage actuation and higher switching speeds. We have explored the theory behind these switching techniques and have demonstrated these techniques in a range of devices including MEMS micromirror devices and in-plane parallel plate MEMS switches. In both devices we have demonstrated switching speeds under one microsecond which has essentially been a firm limit in MEMS switching. We also developed low-loss silicon waveguide technology and the ability to incorporate high-permittivity dielectric materials with MEMS. The successful development of these technologies have generated a number of new projects and have increased both the MEMS switching and optics capabilities of Sandia National Laboratories.

Spahn, Olga Blum; Brewer, Steven; Olsson, Roy H.; Bogart, Gregory R.; Luck, David L.; Watts, Michael R.; Shaw, Michael J.; Nielson, Gregory N.; Resnick, Paul James; Tigges, Christopher P.; Grossetete, Grant David

2008-01-01T23:59:59.000Z

444

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents (OSTI)

A process for fabricating sequential inductors and varactor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varactor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process.

Cooper, Gregory A. (346 Primrose Dr., Pleasant Hill, CA 94523)

1994-01-01T23:59:59.000Z

445

Summary of multiterminal high-voltage direct current transmission technology  

SciTech Connect

This report summarizes the present state of multiterminal (MT) high-voltage direct current (HVDC) power transmission. The purpose is to reassess the need for HVDC circuit breakers and to identify needed research for MT HVDC. The fundamentals of this technology are presented, and previous research and development is reviewed. Although no MT HVDC systems have yet been built, many concepts have been proposed. Some require a dc breaker, and others do not. Both options have advantages and disadvantages for various applications, so the selection will depend on the proposed application. Research is needed to define operating characteristics of various MT HVDC systems. In some applications, dc breakers will be useful, so research into HVDC interruption should continue. Also, dc fault detection and control algorithms for MT systems should be studied.

Biggs, R.B.; Jewell, W.T.

1984-05-01T23:59:59.000Z

446

Patch nearfield acoustic holography in a moving medium  

Science Journals Connector (OSTI)

Abstract To realize the accurate reconstruction of sound field in a moving medium under the condition of limited holographic aperture, a patch nearfield acoustic holography (NAH) in a moving medium is proposed. The proposed method not only reduces the influence caused by the limited aperture effects through sound field extrapolation, but also perfectly suits for sound field reconstruction in a moving medium by improving the shape of the modified Tikhonov regularization filter and the noise estimation method in accordance with flow effects. In the method, two cases that the flow direction is parallel to and perpendicular to the hologram surface are considered. Especially in the perpendicular case, the expression of the wavenumber component in the z direction is improved to make the proposed method suitable for the moving medium at a high Mach number. Simulations are investigated to examine the performance of the proposed method and show its advantages by comparing with NAH in a moving medium and the conventional patch NAH. It is found that, the proposed method is effective and robust at different flow velocities of the medium and different frequencies of the sound source.

Bi-Chun Dong; Chuan-Xing Bi; Xiao-Zheng Zhang; Yong-Bin Zhang

2014-01-01T23:59:59.000Z

447

Sacramento Area Voltage Support Draft Environmental Impact Statement  

SciTech Connect

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the ''National Environmental Policy Act'' (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2002-11-15T23:59:59.000Z

448

Sacramento Area Voltage Support Final Environmental Impact Statement  

SciTech Connect

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the National Environmental Policy Act (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: (1) Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; (2) Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and (3) Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2003-09-19T23:59:59.000Z

449

Some problems THE Galois connection Clones and algebras The lattice of clones Completeness CSP Open problems Clones and Galois connections  

E-Print Network (OSTI)

Some problems THE Galois connection Clones and algebras The lattice of clones Completeness CSP Open aa #12;Some problems THE Galois connection Clones and algebras The lattice of clones Completeness CSP Completeness CSP Open problems Final remarks aa #12;Some problems THE Galois connection Clones and algebras

Pöschel, Reinhard

450

Investigation of dc precise voltage sources for use as Zener transport standard  

SciTech Connect

20 precise compact voltage sources based on zener diodes were manufactured. These sources were under investigation at measuring system in NPO VNIIFTRI during the year. A few sources with voltage drift less than 5 ppm per year and noise level lower than 100 nV in the frequency band of 0,01-10 Hz were selected for manufacturing of 4-channels dc voltage transportable reference standard. This reference standard was investigated by Russian 1-V Josephson systems.

Karpov, O.V.; Shulga, V.M.; Shakirzyanova, F.R. [National Scientifical and Research Institute for Physical Technical and Radiotechnical Measurements, Moscow (Russian Federation)

1994-12-31T23:59:59.000Z

451

HyperConnected: Wireless--extended connectivity Quickly find a network, without opening your  

E-Print Network (OSTI)

wrapping Batteries Primary 4-cell/28 WHr "Smart" Li-Ion battery featuring ExpressChargeTM Primary 6-cell/42 WHr "Smart" Li-Ion battery featuring ExpressChargeTM Primary 9-cell/68 WHr Li-Ion battery CONNECTIVITY at 1.36 kg, is designed for the traveling professionals who demand absolute mobility. With long battery

Fiebig, Peter

452

February 2008 Rev 21 1/49 Very low drop voltage regulators with inhibit  

E-Print Network (OSTI)

. In the three terminal configuration the device has the same electrical performance, but is fixed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 4. Dropout voltage vs output current

Berns, Hans-Gerd

453

Object Oriented Safety Analysis of an Extra High Voltage Substation Bay  

Science Journals Connector (OSTI)

Experiences of application of the object oriented approach to safety analysis of an extra high voltage substation bay are presented. As the first step...

Bartosz Nowicki; Janusz Górski

1998-01-01T23:59:59.000Z

454

Dynamic voltage-current characteristics for a water jet plasma arc  

SciTech Connect

A virtual instrument technology is used to measure arc current, arc voltage, dynamic V-I characteristics, and nonlinear conductance for a cone-shaped water jet plasma arc under ac voltage. Experimental results show that ac arc discharge mainly happens in water vapor evaporated from water when heated. However, due to water's cooling effect and its conductance, arc conductance, reignition voltage, extinguish voltage, and current zero time are very different from those for ac arc discharge in gas work fluid. These can be valuable to further studies on mechanism and characteristics of plasma ac discharge in water, and even in gas work fluid.

Yang Jiaxiang; Lan Sheng; Xu Zuoming [College of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin, Heilongjiang 150040 (China)

2008-05-05T23:59:59.000Z

455

Lab Trials of an Electricity Transmission Line Voltage Sensor Based on Thermally Poled Silica Fibre  

Science Journals Connector (OSTI)

Voltage sensing using helically coiled lengths of thermally poled twin-hole silica optical fibre is presented. Lab accuracy test results showing good linearity and signal to noise...

Michie, Andrew M; Hambley, Philip; Bassett, Ian M; Haywood, John H; Henry, Peter; Ingram, John

456

The design of an A-C voltage regulator using a Wein Bridge detector  

E-Print Network (OSTI)

equipment, which in turn demands a mox'e closely regulated power supply. In satisfying these demands there have been many kinds of voltage regulators designed, constructed, and needs A voltage regulator oonsists essentially of two pax'ts, the "detectox...-V, 424-8, 470 3, 499-503 1950 4. Patchett, G. N. , "The Theory of Nonlinear Bridge Circuit Applied to Voltage Stabilizers, " J. I . E. E . , Vol. 93, Pt. III, p. 18 (1948). 5. Choudbury, J. K. t Das Gupta, S. C. , and Sen, P. C, , "An A-C Voltage...

Brown, Richard True

2012-06-07T23:59:59.000Z

457

Solid State NMR Studies and Local Structure of Voltage Fade Materials  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

with the Voltage Fade Team Michael Slater, Jason Croy, Kevin Gallagher, Christopher Johnson, Yang Ren DOE Vehicle Technologies Program Annual Merit Review Arlington, VA May 13 -...

458

Consideration of 34. 5 KV as an in-plant voltage for a large industrial user  

SciTech Connect

Traditionally, the in-plant distribution voltage for a large refinery or petrochemical complex has been 13.8 kV. Selection of this voltage level was dictated primarily by economic factors, simply because in most cases the magnitude of the loads or the lengths of the feeders did not produce sufficient savings to compensate for the costlier higher voltage switchgear. This paper presents some engineering and cost considerations for distribution at 34.5 kV and attempts to show that this voltage level is both economically and technically feasible for large electrical systems.

Niculescu, T.D.; Regan, R.R.

1983-09-01T23:59:59.000Z

459

E-Print Network 3.0 - affects voltage-gated calcium Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

modulate neuronal voltage-gated calcium cur- rents, we performed a whole-cell patch... that hippocampal neurons in an astrocyte-enriched environment show augmentation of...

460

Theory and practice of dynamic voltage/frequency scaling in the high performance computing environment.  

E-Print Network (OSTI)

?? This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We… (more)

Rountree, Barry Louis

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Grid-Connected Renewable Energy Systems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Grid-Connected Renewable Energy Systems Grid-Connected Renewable Energy Systems Grid-Connected Renewable Energy Systems July 2, 2012 - 8:21pm Addthis When connecting a home energy system to the electric grid, research and consider equipment required as well as your power provider’s requirements and agreements. | Photo courtesy of Solar Design Associates, Inc. When connecting a home energy system to the electric grid, research and consider equipment required as well as your power provider's requirements and agreements. | Photo courtesy of Solar Design Associates, Inc. What are the key facts? While renewable energy systems are capable of powering houses and small businesses without any connection to the electricity grid, many people prefer the advantages that grid-connection offers. Aside from the major small renewable energy system components, you

462

Subsurface connection methods for subsurface heaters  

DOE Patents (OSTI)

A system for heating a subsurface formation is described. The system includes a first elongated heater in a first opening in the formation. The first elongated heater includes an exposed metal section in a portion of the first opening. The portion is below a layer of the formation to be heated. The exposed metal section is exposed to the formation. A second elongated heater is in a second opening in the formation. The second opening connects to the first opening at or near the portion of the first opening below the layer to be heated. At least a portion of an exposed metal section of the second elongated heater is electrically coupled to at least a portion of the exposed metal section of the first elongated heater in the portion of the first opening below the layer to be heated.

Vinegar, Harold J. (Bellaire, TX); Bass, Ronald Marshall (Houston, TX); Kim, Dong Sub (Sugar Land, TX); Mason, Stanley Leroy (Allen, TX); Stegemeier, George Leo (Houston, TX); Keltner, Thomas Joseph (Spring, TX); Carl, Jr., Frederick Gordon (Houston, TX)

2010-12-28T23:59:59.000Z

463

To connect to Boiler Television, you will need to provide a coaxial cable to connect your television set to the cable wall outlet. In connecting the coaxial  

E-Print Network (OSTI)

To connect to Boiler Television, you will need to provide a coaxial cable to connect your? By providing this initial information, you help Boiler Television staff assess and resolve this issue as soon for use with any University Residences work request -- not just for the Boiler Television system. Set

Ginzel, Matthew

464

The Distribution of Pressures in a Supernova-Driven Interstellar Medium. I. Magnetized Medium  

E-Print Network (OSTI)

Observations have suggested substantial departures from pressure equilibrium in the interstellar medium (ISM) in the plane of the Galaxy, even on scales under 50 pc. Nevertheless, multi-phase models of the ISM assume at least locally isobaric gas. The pressure then determines the density reached by gas cooling to stable thermal equilibrium. We use numerical models of the magnetized ISM to examine the consequences of supernova driving for interstellar pressures. In this paper we examine a (200 pc)^3 periodic domain threaded by magnetic fields. Individual parcels of gas at different pressures reach widely varying points on the thermal equilibrium curve: no unique set of phases is found, but rather a dynamically-determined continuum of densities and temperatures. A substantial fraction of the gas remains entirely out of thermal equilibrium. Our results appear consistent with observations of interstellar pressures. They also suggest that the high pressures observed in molecular clouds may be due to ram pressures in addition to gravitational forces. Much of the gas in our model lies far from equipartition between thermal and magnetic pressures, with ratios ranging from 0.1 to $10^4$ and ratios of uniform to fluctuating magnetic field of 0.5--1. Our models show broad pressure probability distribution functions with log-normal functional forms produced by both shocks and rarefaction waves, rather than power-law distributions produced by isolated supernova remnants. The width of the distribution can be described quantitatively by a formula derived from the work of Padoan, Nordlund, & Jones (1997).

Mordecai-Mark Mac Low; Dinshaw S. Balsara; Jongsoo Kim; Miguel A. Avillez

2004-10-29T23:59:59.000Z

465

Heat transfer modeling at an interface between a porous medium and a free region.  

E-Print Network (OSTI)

??This work deals with the study of heat transfer between a porous medium and a free medium, using multi scale approaches. First, we derive the… (more)

D'hueppe, Aliénor

2011-01-01T23:59:59.000Z

466

E-Print Network 3.0 - areas medium sized Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Medium... file with tables 12;Simulation Progress Modeled 802.15.4 Medium Access Control (MAC) and Physical Source: National Institute of Standards and Technology (NIST),...

467

E-Print Network 3.0 - alkaline medium peliculas Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

rate: medium Texture: medium Foliage Leaf arrangement: alternate (Fig... requirement: tree grows in full sun Soil tolerances: clay; loam; sand; slightly alkaline; acidic;...

468

Seamless sustainable transport connectivity in Asia and the Pacific: prospects and challenges  

Science Journals Connector (OSTI)

Connectivity has several dimensions, such as physical infrastructure (physical connectivity), effective institutions, mechanisms and processes (institutional connectivity) and empowerment (people-to-people con...

Biswa Nath Bhattacharyay

2012-06-01T23:59:59.000Z

469

Variable Voltage Substation Electric Fire and Emergency Response  

Energy.gov (U.S. Department of Energy (DOE))

Variable Voltage Substation Electric Fire and Emergency Response My question is from an emergency response perspective. You stated that it took ~ ˝ for electricians to de-energize the electrical components before firefighters were allowed in to fight the fire. This delay causes more damage to equipment and potential propagation of the fire. Is there not a “master” breaker or switch? You’ve brought up a very good point. It gave me a good opportunity to discuss this with our Facilities Department and get a better understanding of the infrastructure upgrade plans. The direct answer to your question is “Yes, but…” Yes, there are “master” breakers and switches, but we can’t control them remotely. SLAC’s AC electrical distribution system at present is manual breakers – we have not installed the infrastructure to remotely control them (except see below). We recently underwent an upgrade to our Master Substation that will allow us to remotely control some high voltage breakers in the future, but we aren’t there yet. We do recognize the value in having this capability (and more importantly, our vulnerability in NOT having it), and have begun the preliminary planning to make this happen. One issue were are working on is cyber security for the power distribution networked infrastructure. Before we install the capability to remotely control the main electrical breakers, we are planning the infrastructure with our Information Technologies organization to ensure we have a robust secure network that is protected from unauthorized access. Once the cyber security issues are addressed and funded, we’re probably 5-10 years out from having remote operation capability due to limited resources to fund and install the infrastructure. Having said the above, we do have the capability of remotely opening the VVS Secondary Main Breakers – the ones that send power to the modulator distribution breakers - from our control room. Those breakers are integral parts of our safety systems in that interlock violation causes the breakers to open and remove power to the klystrons. But everything else is manual only. That remote operation capability would not have helped us in this case, as the VVS Secondary Main Breaker was the one that fried. We needed to open the breaker upstream of the VVS. Thanks for your interest. Let me know if I can provide further information.

470

An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context  

E-Print Network (OSTI)

An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context Yassine Amirat1,2 , Mohamed Benbouzid2 , Tianzhen Wang3 and Sylvie Turri2 Abstract­Smart grids have become, using the instantaneous power for voltage sags detection in smart grids. Copyright © 2013 Praise Worthy

Brest, Université de

471

Hydroelectric Voltage Generation Based on Water-Filled Single-Walled Carbon Nanotubes  

Science Journals Connector (OSTI)

Hydroelectric Voltage Generation Based on Water-Filled Single-Walled Carbon Nanotubes ... The hydroelectric voltage generator can be expressed by the model illustrated in Figure 6a and b. ... Individual water-filled single-walled carbon nanotubes as hydroelectric power converters ...

Quanzi Yuan; Ya-Pu Zhao

2009-04-21T23:59:59.000Z

472

Integrating a Feature Selection Algorithm for Classification of Voltage Sags Originated in Transmission and Distribution Networks  

Science Journals Connector (OSTI)

As a global problem in the power quality area, voltage sags are matter of high interest for both utilities and customers. With a view to resolving the problem of sag source location in the power network, this paper introduces a new method based on dimension ... Keywords: Direction, Hybrid Method, Mpca, Voltage Sag

Abbas Khosravi; Toni Martinez; Joaquim Melendez; Joan Colomer; Jorge Sanchez

2007-06-01T23:59:59.000Z

473

A Static Pattern-Independent Technique for Power Grid Voltage Integrity Verification  

E-Print Network (OSTI)

A Static Pattern-Independent Technique for Power Grid Voltage Integrity Verification Dionysios Design verification must include the power grid. Checking that the voltage on the power grid does) the obviously large size of the power grids for modern high-performance chips, and ii) the difficulty of setting

Najm, Farid N.

474

A Static PatternIndependent Technique for Power Grid Voltage Integrity Verification #  

E-Print Network (OSTI)

A Static Pattern­Independent Technique for Power Grid Voltage Integrity Verification # Dionysios Design verification must include the power grid. Checking that the voltage on the power grid does) the obviously large size of the power grids for modern high­performance chips, and ii) the di#culty of setting

Najm, Farid N.

475

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators  

E-Print Network (OSTI)

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators General Description The LM clock timers; multivibrators and high voltage digital logic gates. The LM193 series was designed to directly interface with TTL and CMOS. When operated from both plus and minus power supplies, the LM193

Lanterman, Aaron

476

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions  

E-Print Network (OSTI)

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 19-1 High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 1. DC Properties of Modern Filled Epoxy Insulation Academic and Research Staff Dr. Chathan Cooke Sponsor

477

Creation of Onset Voltage Hash by Anode Spots in a Magnetoplasmadynamic Thruster  

E-Print Network (OSTI)

Creation of Onset Voltage Hash by Anode Spots in a Magnetoplasmadynamic Thruster Luke Uribarri flow rate) of onset voltage fluctuations in a magnetoplasmadynamic thruster operating with three anode materials, and an anode spot model is presented which provides a physical explanation for the properties

Choueiri, Edgar

478

The Onset of Voltage Hash and its Relationship to Anode Spots in Magnetoplasmadynamic Thrusters  

E-Print Network (OSTI)

The Onset of Voltage Hash and its Relationship to Anode Spots in Magnetoplasmadynamic Thrusters, 08544 A phenomenological model is developed to elucidate the relationship between voltage hash and anode electromagnetic force density leads to a mass depletion in the anode region which, in turn, leads to a disparity

Choueiri, Edgar

479

Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power System  

E-Print Network (OSTI)

Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power collapse will occurs in a wind power system is discussed next. The method of power flow calculation is the specific analysis of a given simplified wind power system. Keywords--voltage collapse; Newton

Lavaei, Javad

480

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal Dutta  

E-Print Network (OSTI)

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal}@eecs.umich.edu culler@cs.berkeley.edu Abstract AC power meters require both voltage and current to be sampled physical proximity and fed into a single power metering de- vice. In this paper, we explore the viability

Dutta, Prabal

Note: This page contains sample records for the topic "medium voltage connection" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Onset Voltage Hash and Anode Spots in Quasi-Steady Magnetoplasmadynamic  

E-Print Network (OSTI)

Onset Voltage Hash and Anode Spots in Quasi-Steady Magnetoplasmadynamic Thrusters Luke Uribarri: Edgar Y. Choueiri November 2008 #12;ONSET VOLTAGE HASH AND ANODE SPOTS IN QUASI noise ("hash") and anode damage in a self-field, quasi-steady magnetoplasmadynamic thruster (MPDT

Choueiri, Edgar

482

Scaling of Anode Sheath Voltage Fall with the Operational Parameters in Applied-Field MPD  

E-Print Network (OSTI)

Scaling of Anode Sheath Voltage Fall with the Operational Parameters in Applied-Field MPD Thrusters (EPPDyL) Princeton University, Princeton, NJ, 08544, USA Scaling laws for the anode sheath voltage fall in applied-field MPD thrusters are derived in order to better understand the physics behind anode sheath

Choueiri, Edgar

483

Reactive power management of distribution networks with wind generation for improving voltage stability  

E-Print Network (OSTI)

Reactive power management of distribution networks with wind generation for improving voltage February 2013 Available online Keywords: Composite load Distributed generation D-STATCOM Q with distributed wind generation. Firstly, the impact of high wind penetration on the static voltage stability

Pota, Himanshu Roy

484

Voltage Control of Distribution Networks with Distributed Generation using Reactive Power  

E-Print Network (OSTI)

Voltage Control of Distribution Networks with Distributed Generation using Reactive Power. Nasiruzzaman Abstract--Voltage profile of distribution networks with dis- tributed generation are affected significantly due to the integra- tion of distributed generation (DG) on it. This paper presents a way

Pota, Himanshu Roy

485

Direct Power Control of Doubly-Fed Generator Based Wind Turbine Converters to Improve Low Voltage  

E-Print Network (OSTI)

Control (DPC) is discussed for Low Voltage Ride Through (LVRT) of DFIG based wind turbine converters power integration state that doubly fed induction generator (DFIG) controllers should be capable and maintaining dc bus voltage, then the DFIG will stay online during the disturbance. A fast acting controller

Kimball, Jonathan W.

486

Energy Aware Dynamic Voltage and Frequency Selection for Real-Time Systems with Energy Harvesting  

E-Print Network (OSTI)

Energy Aware Dynamic Voltage and Frequency Selection for Real-Time Systems with Energy Harvesting}@binghamton.edu Abstract In this paper, an energy aware dynamic voltage and frequency selection (EA-DVFS) algorithm energy and the harvested energy in a future duration. Specifically, if the system has sufficient energy

Qiu, Qinru

487

The high voltage problem in the saturated core HTS fault current limiter  

Science Journals Connector (OSTI)

A small model of a one-phase saturated core HTS fault current limiter was developed. It consists of an iron core, an AC coil and a DC HTS coil. The HTS coil comprised six 126 turns double-pancakes (ID 70 mm), wound after heat treatment from Bi-2223 multifilamentary tape in Ag matrix. A fault simulation circuit was set up to characterize the dynamic properties of the model limiter. The voltages and currents of the AC coil and the DC HTS coil were measured through a computer-based data acquisition system. The tests have shown that the limiter has a fast response and the first current peak can be easily limited, but a high voltage will be induced on the DC HTS coil side during the fault state. This high voltage can badly affect the DC current equipment on the DC HTS coil side. The origin and value of the high voltage can be explained using a transformer model. For a limiter with n1 turns AC coil and n2 turns DC coil, the largest induced voltage will be roughly close to (n2/n1)U, where U is the rated voltage of the limiter. To commercialize this kind of limiter, the high voltage problem must be solved. Some different designs were introduced to lower the induced voltage.

Y.F. He; J.H. Li; X.H. Zong; J. Sun; Y.N. Wang; C.L. Wu; J.X. Wang

2003-01-01T23:59:59.000Z

488

Evaluation of Insulation Systems for the Optimal Design of High Voltage Pulse Transformers  

E-Print Network (OSTI)

This paper presents a study for the design of the insulation systems of high voltage pulse transformer based on experimental tests and numerical simulations. Data of high voltage tests on solid and liquid insulation materials are presented and discussed. The understanding of each part of the insulation is supported by electrostatic fields simulations.

Sylvain, Candolfi; Davide, Aguglia; Philippe, Viarouge; Jürgen, Biela; Jerome, Cros

2015-01-01T23:59:59.000Z

489

DECENTRALIZED VOLTAGE CONTROL TO MINIMIZE DISTRIBUTION LOSSES IN AN ISLANDED MICROGRID  

E-Print Network (OSTI)

power sources and energy storage systems such as batteries requires new power and voltage control-time voltage control algorithm that minimizes power losses for a microgrid supported by inverter based Microgrids can bring electricity power to rural communities or isolated military forward operation bases

Peng, Huei

490

The activated state of a sodium channel voltage sensor in a membrane environment  

Science Journals Connector (OSTI)

...suggests a displacement of ?4 elementary charges per subunit across...voltage sensor reveals a focused electric field . Nature 427 ( 6974...CA Horn R ( 2005 ) Focused electric field across the voltage sensor of potassium...protease activity for protamine resistance of Escherichia coli . Arch...

Sudha Chakrapani; Pornthep Sompornpisut; Pathumwadee Intharathep; Benoît Roux; Eduardo Perozo

2010-01-01T23:59:59.000Z

491

Public Opinions of Building Additional High-Voltage Electric Power Lines  

E-Print Network (OSTI)

to build new power lines. Residents living in counties with planned routes for new transmission linesPublic Opinions of Building Additional High-Voltage Electric Power Lines A Report to the National-Voltage Electric Power Lines: A Report to the National Science Foundation and the Electric Power Research Center

Tesfatsion, Leigh

492

A new technique to reject dc-link voltage ripple in PWM inverters  

E-Print Network (OSTI)

on the rlc-link, is numerically calculated. Let us assume, Inverfer output frequency f, ? 60 Hz Vs, = 1 pu Dc ? link voltage rrpple = k Vs, ? 0. 2 x Vge = . 2 pu Dc ? link voltage ripple frequency f, = 120 Hz :tfodulation index ? 0. 5 Frequency spectrum...

Shireen, Wajiha

1990-01-01T23:59:59.000Z

493

Training Manual for Micro, Small and Medium Entrepreneurs in Energy  

Open Energy Info (EERE)

Training Manual for Micro, Small and Medium Entrepreneurs in Energy Training Manual for Micro, Small and Medium Entrepreneurs in Energy Business Financing Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Training Manual for Micro, Small and Medium Entrepreneurs in Energy Business Financing Agency/Company /Organization: GVEP International Sector: Energy Focus Area: Renewable Energy, Non-renewable Energy Phase: Bring the Right People Together, Create a Vision, Determine Baseline, Evaluate Options, Develop Goals, Prepare a Plan Topics: Finance Resource Type: Training materials User Interface: Website Website: www.gvepinternational.org/sites/default/files/manual_for_sme_energy_fi Cost: Free UN Region: Eastern Africa Language: English The training manual is developed as a modular guide to enable energy entrepreneurs to acquire supplementary knowledge in order to expand their

494

Guidelines and Toolkits for Urban Transport Development in Medium Sized  

Open Energy Info (EERE)

Guidelines and Toolkits for Urban Transport Development in Medium Sized Guidelines and Toolkits for Urban Transport Development in Medium Sized Cities in India Jump to: navigation, search Tool Summary Name: Guidelines and Toolkits for Urban Transport Development in Medium Sized Cities in India Agency/Company /Organization: Asian Development Bank Focus Area: Governance - Planning - Decision-Making Structure Topics: Best Practices Complexity/Ease of Use: Not Available Website: sti-india-uttoolkit.adb.org/ Transport Toolkit Region(s): Asia Related Tools Promoting Clean Cars: Case Study of Stockholm and Sweden MOtor Vehicle Emission Simulator (MOVES) The World Bank - Transport ... further results Find Another Tool FIND TRANSPORTATION TOOLS This resource is designed to help decision makers and practitioners in states and municipal governments who are concerned with urban transport

495

JC3 Medium Impact Assessment Bulletins | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Medium Impact Medium Impact Assessment Bulletins JC3 Medium Impact Assessment Bulletins RSS September 9, 2013 V-237: TYPO3 Security Bypass Vulnerabilities TYPO3 comes with the possibility to restrict editors to certain file actions (copy, delete, move etc.) and to restrict these actions to be performed in certain locations September 4, 2013 V-234: EMC RSA Archer GRC Open Redirection Weakness and Security Bypass Security Issue This fixes multiple vulnerabilities, which can be exploited to bypass certain security restrictions and to conduct spoofing attacks September 3, 2013 V-233: Red Hat update for JBoss Fuse This fixes multiple vulnerabilities, which can be exploited by malicious people to bypass certain security restrictions and cause a DoS. August 28, 2013 V-229: IBM Lotus iNotes Input Validation Flaws Permit Cross-Site Scripting

496

The role of the mobile medium in multichannel CRM communication  

Science Journals Connector (OSTI)

Research concerning the multichannel environment in different industries and contexts is increasing. However, the majority of studies fail to acknowledge the different characteristics of each individual channel. Therefore, this study takes a closer look at the mobile medium within the multichannel environment in CRM. More specifically, the purpose of this study is to examine the role of the mobile medium among other channels within multichannel CRM communication. Based on the purpose of the study, this research builds on an empirical single-case study in the airline industry. The findings of the study indicate that the mobile medium has an important, albeit complementary, role within multichannel CRM communication. The role is enhanced when the company takes into account the phase of the customer relationship and, moreover, the customers' travelling process.

Jaakko Sinisalo

2011-01-01T23:59:59.000Z

497

Quantum-mechanical description of in-medium fragmentation  

E-Print Network (OSTI)

We present a quantum-mechanical description of quark-hadron fragmentation in a nuclear environment. It employs the path-integral formulation of quantum mechanics, which takes care of all phases and interferences, and which contains all relevant time scales, like production, coherence, formation, etc. The cross section includes the probability of pre-hadron (colorless dipole) production both inside and outside the medium. Moreover, it also includes inside-outside production, which is a typical quantum-mechanical interference effect (like twin-slit electron propagation). We observe a substantial suppression caused by the medium, even if the pre-hadron is produced outside the medium and no energy loss is involved. This important source of suppression is missed in the usual energy-loss scenario interpreting the effect of jet quenching observed in heavy ion collisions. This may be one of the reasons of a too large gluon density, reported by such analyzes.

B. Z. Kopeliovich; H. -J. Pirner; I. K. Potashnikova; Ivan Schmidt; A. V. Tarasov; O. O. Voskresenskaya

2008-09-27T23:59:59.000Z

498

Demand response medium sized industry consumers (Smart Grid Project) | Open  

Open Energy Info (EERE)

response medium sized industry consumers (Smart Grid Project) response medium sized industry consumers (Smart Grid Project) Jump to: navigation, search Project Name Demand response medium sized industry consumers Country Denmark Headquarters Location Aarhus, Denmark Coordinates 56.162937°, 10.203921° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":56.162937,"lon":10.203921,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

499

Feature - Fuel Economy for Medium- and Heavy-Duty Vehicles  

NLE Websites -- All DOE Office Websites (Extended Search)

New Report Looks at Fuel Economy for Medium- and Heavy-Duty Vehicles New Report Looks at Fuel Economy for Medium- and Heavy-Duty Vehicles heavy duty trucks Argonne researcher Aymeric Rousseau was part of a National Academy of Science (NAS) committee established to make recommendations on improving and regulating fuel consumption for medium- and heavy-duty vehicles. On March 31, the committee issued a report that evaluates various technologies and methods that could improve the fuel economy of these vehicles. As a system analysis engineer at Argonne's Center for Transportation Research, Rousseau contributed his expertise on vehicle modeling and simulation to the committee, which was comprised of 19 members from industry, research organizations and academia. Rousseau, who leads the development of Argonne's PSAT and Autonomie software tools, helped the committee determine how modeling and simulation tools can be used to:

500

High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report | Open  

Open Energy Info (EERE)

High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report Jump to: navigation, search Tool Summary LAUNCH TOOL Name: High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report Focus Area: Crosscutting Topics: Policy Impacts Website: www.netl.doe.gov/smartgrid/referenceshelf/reports/HV-BPL_Final_Report. Equivalent URI: cleanenergysolutions.org/content/high-voltage-broadband-over-powerline Language: English Policies: "Deployment Programs,Financial Incentives" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Technical Assistance This reports details findings from a pilot High Voltage Broadband over Power Line (HV-BPL) program, an effort to develop a disruptive technology